WorldWideScience

Sample records for axial field spectrometer

  1. View of the Axial Field Spectrometer

    CERN Multimedia

    1980-01-01

    The Axial Field Spectrometer, with the vertical uranium/scintillator calorimeter and the central drift chamber retracted for service. One coil of the Open Axial Field Magnet is just visible to the right.

  2. View of the Axial Field Spectrometer (R807)

    CERN Multimedia

    1980-01-01

    In this view of the Axial Field Spectrometer at I8, the vertical uranium/scintillator hadron calorimeter (just left of centre) is retracted to give access to the cylindrical central drift chamber. The yellow iron structure served as a filter to identify muons, with MWPCs and the array of Cherenkov counters to the right.

  3. Overview of the Axial Field Spectrometer in the ISR tunnel

    CERN Multimedia

    1980-01-01

    A view of the Axial Field Spectrometer – the last large experiment at the ISR. The horizontal top and vertical outer arrays of the uranium-scintillator hadron calorimeter are clear to be seen, with the blue cylindrical pole piece of the magnet just visible. The pipes that are visible in front of the pole piece are cryogenic feed pipes for the superconducting low-beta quadrupoles.

  4. Study of $ \\bar{p} $ and $ \\bar{n} $ annihilations at LEAR with OBELIX, a large acceptance and high resolution detector based on the Open Axial Field Spectrometer

    CERN Multimedia

    2002-01-01

    % PS201 Study of $\\bar{p}$ and $\\bar{n}$ annihilations at LEAR with OBELIX, a large acceptance and high resolution detector based on the Open Axial Field Spectrometer \\\\ \\\\OBELIX is designed to study exclusive final states of antiproton and antineutron annihilations at low energies with protons and nuclei. \\\\ \\\\The physics motivations of the experiment are:\\\\ \\\\\\begin{itemize} \\item (gg, ggg), hybrids ($ q \\bar{q} g $), multiquarks ($ q q \\bar{q} \\bar{q} $) and light mesons ($ q \\bar{q} $) produced in $ N \\bar{N} $ annihilations and study of their spectroscopy and decays. Also broad structures will be searched for by comparing identical decay modes in exclusive final states of the same type occuring from initial states with different angular momentum or isospin. \\item Study of the dynamics of $ N \\bar{N} $ interactions and of the dependence of the final and intermediate resonant states of annihilation upon the quantum numbers of the initial $ N \\bar{N} $ state (angular momentum: S and P-wave in $\\bar{p}p $ at...

  5. Build Axial Gradient Field by Using Axial Magnetized Permanent Rings

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Axial magnetic field produced by an axial magnetized permanent ring was studied. For two permanent rings, if they are magnetized in the same directions, a nearly uniform axial field can be produced. If they are magnetized in opposite direction,an axial gradient magnetic field can be generated, with the field range changing from -B0 to B0. A permanent magnet with a high axial gradient field was fabricated, the measured results agree with the PANDIRA calculation very well. For wider usage,it is desirable for the field gradient to be changed. Some methods to produce the variable gradient field are presented. These kinds of axial gradient magnetic field can also be used as a beam focusing for linear accelerator if the periodic field can be produced along the beam trajectory. The axial magnetic field is something like a solenoid, large stray field will leak to the outside environment if no method is taken to control them. In this paper, one method is illustrated to shield off the outside leakage field.

  6. High-resolution spectrometer: solution to the axial resolution and ranging depth trade-off of SD-OCT

    Science.gov (United States)

    Marvdashti, Tahereh; Lee, Hee Yoon; Ellerbee, Audrey K.

    2013-03-01

    We demonstrate a cross-dispersed spectrometer for Spectral Domain Optical Coherence Tomography (SD-OCT). The resolution of a conventional SD-OCT spectrometer is limited by the available sizes of the linear array detectors. The adverse consequences of this finite resolution is a trade-off between achieving practical field of view (i.e. ranging depth) and maintaining high axial resolution. Inspired by spectrometer designs for astronomy, we take advantage of very high pixel-density 2D CCD arrays to map a single-shot 2D spectrum to an OCT A-scan. The basic system can be implemented using a high-resolution Echelle grating crossed with a prism in a direction orthogonal to the dispersion axis. In this geometry, the interferometric light returning from the OCT system is dispersed in two dimensions; the resulting spectrum can achieve more pixels than a traditional OCT spectrometer (which increases the ranging depth) and maintains impressive axial resolution because of the broad bandwidth of the detected OCT light. To the best of our knowledge, we present the first demonstration of OCT data using an Echelle-based cross-dispersed spectrometer. Potential applications for such a system include high-resolution imaging of the retina or the anterior segment of the eye over extended imaging depths and small animal imaging.

  7. Axially symmetric static sources of gravitational field

    CERN Document Server

    Hernandez-Pastora, J L; Martin, J

    2016-01-01

    A general procedure to find static and axially symmetric, interior solutions to the Einstein equations is presented. All the so obtained solutions, verify the energy conditions for a wide range of values of the parameters, and match smoothly to some exterior solution of the Weyl family, thereby representing globally regular models describing non spherical sources of gravitational field. In the spherically symmetric limit, all our models converge to the well known incompressible perfect fluid solution.The key stone of our approach is based on an ansatz allowing to define the interior metric in terms of the exterior metric functions evaluated at the boundary source. Some particular sources are obtained, and the physical variables of the energy-momentum tensor are calculated explicitly, as well as the geometry of the source in terms of the relativistic multipole moments. The total mass of different configurations is also calculated, it is shown to be equal to the monopole of the exterior solution.

  8. MICE Spectrometer Solenoid Magnetic Field Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Leonova, M. [Fermilab

    2013-09-01

    The Muon Ionization Cooling Experiment (MICE) is designed to demonstrate ionization cooling in a muon beam. Its goal is to measure a 10% change in transverse emittance of a muon beam going through a prototype Neutrino Factory cooling channel section with an absolute measurement accuracy of 0.1%. To measure emittances, MICE uses two solenoidal spectrometers, with Solenoid magnets designed to have 4 T fields, uniform at 3 per mil level in the tracking volumes. Magnetic field measurements of the Spectrometer Solenoid magnet SS2, and analysis of coil parameters for input into magnet models will be discussed.

  9. Effects of external axial magnetic field on fast electron propagation

    International Nuclear Information System (INIS)

    A scheme employing an external axial magnetic field is proposed to diagnose the intrinsic divergence of laser-generated fast electron beams, and this is studied numerically with hybrid simulations. The maximum beam radius of fast electrons increases with the initial divergence and decreases with the amplitude of the axial magnetic field. It is indicated that the intrinsic divergence of fast electrons can be inferred from measurements of the beam radius at different depth under the axial field. The proposed scheme here may be useful for future fast ignition experiments and in other applications of laser-generated fast electron beams.

  10. Imaging spectrometer wide field catadioptric design

    Science.gov (United States)

    Chrisp; Michael P.

    2008-08-19

    A wide field catadioptric imaging spectrometer with an immersive diffraction grating that compensates optical distortions. The catadioptric design has zero Petzval field curvature. The imaging spectrometer comprises an entrance slit for transmitting light, a system with a catadioptric lens and a dioptric lens for receiving the light and directing the light, an immersion grating, and a detector array. The entrance slit, the system for receiving the light, the immersion grating, and the detector array are positioned wherein the entrance slit transmits light to the system for receiving the light and the system for receiving the light directs the light to the immersion grating and the immersion grating receives the light and directs the light through the system for receiving the light to the detector array.

  11. Nuclear Axial Currents in Chiral Effective Field Theory

    OpenAIRE

    Baroni, A.; Girlanda, L.; Pastore, S.; Schiavilla, R.; Viviani, M

    2015-01-01

    Two-nucleon axial charge and current operators are derived in chiral effective field theory up to one loop. The derivation is based on time-ordered perturbation theory, and accounts for cancellations between the contributions of irreducible diagrams and the contributions due to non-static corrections from energy denominators of reducible diagrams. Ultraviolet divergencies associated with the loop corrections are isolated in dimensional regularization. The resulting axial current is finite and...

  12. A co-axially configured submillimeter spectrometer and investigations of hydrogen bound molecular complexes

    Science.gov (United States)

    McElmurry, Blake Anthony

    The development of a co-axially configured submillimeter spectrometer is reported. The spectrometer has been constructed to observe molecular complexes that exhibit non-covalent interactions with energies much less than that of a traditional covalent bond. The structure of molecular complexes such as those formed between a rare gas and a hydrogen halide, Rg:HX where Rg is a rare gas (Rg=Ne, Ar and Kr) and HX (X=F, Cl, Br and I) can be determined directly and accurately. The center of mass interaction distance, RCM, as well as the angle of the hydrogen halide is determined, along with direct evaluation of the intermolecular vibrations as well as accurate isomerization energies between the hydrogen bound and van der Waals forms. The accuracy of the frequency determination of rovibrational transitions using the submillimeter spectrometer is also evaluated by direct comparison with the state-of-the-art pulsed nozzle Fourier transform microwave spectrometer, and this accuracy is estimated to be less than 1 kHz at 300 GHz. The tunneling or geared bending vibration of a dimer of hydrogen bromide or hydrogen iodide has been investigated. The selection rules, nuclear statistics and intensity alternation for transitions observed in these dimmers, which is a consequence of interchanging two identical nuclei in the low frequency geared bending vibration of the molecular complex, are reported. Furthermore, the rotation and quadrupole coupling constants are used to determine a vibrationally averaged structure of the complex. The energy of the low frequency bending vibration can then be compared with ab initio based potential energy surfaces. A study of the multiple isomeric forms of the molecular complex OC:HI is also presented. Multiple isotopic substitutions are used to determine the relevant ground state structures and data reported evidence for an anomalous isotope effect supporting a ground state isotopic isomerization effect. All spectroscopic data that has been reported

  13. A Bonner Sphere Spectrometer for pulsed fields.

    Science.gov (United States)

    Aza, E; Dinar, N; Manessi, G P; Silari, M

    2016-02-01

    The use of conventional Bonner Sphere Spectrometers (BSS) in pulsed neutron fields (PNF) is limited by the fact that proportional counters, usually employed as the thermal neutron detectors, suffer from dead time losses and show severe underestimation of the neutron interaction rate, which leads to strong distortion of the calculated spectrum. In order to avoid these limitations, an innovative BSS, called BSS-LUPIN, has been developed for measuring in PNF. This paper describes the physical characteristics of the device and its working principle, together with the results of Monte Carlo simulations of its response matrix. The BSS-LUPIN has been tested in the stray neutron field at the CERN Proton Synchrotron, by comparing the spectra obtained with the new device, the conventional CERN BSS and via Monte Carlo simulations. PMID:25948828

  14. Partial view of the Axial Field Spectrometer (version R808)

    CERN Multimedia

    1980-01-01

    The endplates of the cylindrical drift chamber is removed to access the electronics. The vertical Uranium/Scintillator Calorimeter is retracted. The detector on the frontface is a matrix of NaI-crystals for photon spectroscopy

  15. Study and construction of a β-spectrometer of uniform axial magnetic field fitted with a β-γ coincidence selector. Study of the β spectra of 32P, 203Hg, 198Au. Measurement of the conversion coefficients of 203Ti and of 198Hg

    International Nuclear Information System (INIS)

    In the first part is given the principle of the beta spectrometer with uniform axial field using systematically the idea of caustics. The apparatus is described and its properties compared to those deduced from trajectory calculations. The β-ray and γ-ray detectors and the device for selecting coincidences with a 2 τ resolution of 5 nanoseconds are also presented. In the second part, the spectrometer is used for studying reference elements and the most accurate results are confirmed. The β spectrum of 60Co has a statistical form with an accuracy of 1 per cent; the maximum energy E0 is 316.5 ± 1.5 keV. That of the 7/2 + → 11/2 transition for 137Cs has a unique form, once forbidden. E0= 522 ± 3 keV. Conversion coefficients αk = 96 ± 1 X 10-3 αL + M + N = 20.9 ± 0.5 X 10-3. The two β spectra of 59Fe, separated by coincidence with the gamma, have the statistical form E0 = 462 ± 2 keV (55.1 + 0,3 per cent) and E1 = 275 ± 4 keV (44.9 ± 0.3 per cent). It is then verified whether the l selection rule is apparent in the shape of the phosphorus 32 beta spectrum. It is found in fact that it is not of statistical shape and its shape coefficient is determined. For a theoretical interpretation it is necessary to have better approximations than those generally used and this interpretation will not be unique. This work has also made it possible to show that the source contains a small proportion of 33P. The study of the 203Hg β spectrum followed by the 279 keV gamma spectrum is designed to determine the conversion coefficients. The interior spectrum of gold 198 is not of statistical shape either. The form coefficient is determined together with the conversion coefficients which are in slight disagreement with those calculated by Rose or Sliv. An interpretation of the spectrum is put forward which proposes an imperfect compensation for the various elements of the matrix. (author)

  16. Axial field permanent magnet DC motor with powder iron armature

    OpenAIRE

    Sharkh, Suleiman M.A.; Mohammad, Mohammad T.

    2007-01-01

    The paper describes a double-gap axial field permanent magnet (PM) dc motor whose double-layer armature wave winding is constructed of copper strips. It investigates the performance of two machines using powder iron and lamination steel materials as armature teeth. Tests are conducted to evaluate the motor torque and speed curves as well as their efficiency under different loads. Finite element analysis (FEA) and equivalent circuit models are used to determine the levels of the magnetic satur...

  17. Vacuum arc under axial magnetic fields: experimental and simulation research

    International Nuclear Information System (INIS)

    Axial magnetic field (AMF) technology is a most important control method of vacuum arc, particularly for high-current vacuum arcs in vacuum interrupters. In this paper, a review of the state of current research on vacuum arcs under AMF is presented. The major aspects of vacuum arc in an AMF such as arc voltage, the motion of cathode spots, and anode activities are discussed, and the most recent progress both of experimental and simulation research is presented. (topical review)

  18. Experimental studies of axial magnetic fields generated in ultrashort-pulse laser-plasma interaction

    Institute of Scientific and Technical Information of China (English)

    李玉同; 张杰; 陈黎明; 赵理曾; 夏江帆; 魏志义; 江文勉

    2000-01-01

    The quasistatic axial magnetic fields in plasmas produced by ultrashort laser pulses were measured by measuring the Faraday rotation angle of the backscattered emission. The spatial distribution of the axial magnetic field was obtained with a peak value as high as 170 Tesla. Theory suggests that the axial magnetic field is generated by dynamo effect in laser-plasma interaction.

  19. Flow field interference characteristic of axial ring wing configuration

    OpenAIRE

    Qi, Duo; Jinfu, Feng; Jiaqiang, Zhang; Yongli, Li

    2016-01-01

    To analyze the air flow interference between upper and lower wings in axial ring wing configuration, NASA SC(2)-1006 supercritical airfoil is chosen as the basic airfoil. Flow field around the double-wing structure with different relative distances between upper and lower wings is numerically simulated, using SST  turbulence model, and the numerical conclusion about the influence of relative distance D/L on the aerodynamic performance is drawn. It is shown that, at the speed Ma = 0.8, reflect...

  20. Electric and magnetic field optimization procedure for Penning trap mass spectrometers

    CERN Document Server

    Beck, D; Bollen, G; Delahaye, P; George, S; Guénaut, C; Herfurth, F; Herlert, A; Lunney, D; Schweikhard, L; Yazidjian, C

    2009-01-01

    Significant systematic errors in high-precision Penning trap mass spectrometry can result from electric and magnetic field imperfections. An experimental procedure to minimize these uncertainties is presented for the on-line Penning trap mass spectrometer ISOLTRAP, located at ISOLDE/CERN. The deviations from the ideal magnetic and electric fields are probed by measuring the cyclotron frequency and the reduced cyclotron frequency, respectively, of stored ions as a function of the time between the ejection of ions from the preparation trap and their capture in the precision trap, which influences the energy of their axial motion. The correction parameters are adjusted to minimize the frequency shifts.

  1. Analysis of brushless DC generator incorporating an axial field coil

    Energy Technology Data Exchange (ETDEWEB)

    Moradi, Hassan, E-mail: H_moradi@sbu.ac.i [Department of Electrical and Computer Engineering, Shahid Beheshti University, GC, Tehran (Iran, Islamic Republic of); Afjei, E. [Department of Electrical and Computer Engineering, Shahid Beheshti University, GC, Tehran (Iran, Islamic Republic of)

    2011-07-15

    Highlights: {yields} Magnetic analysis and experiment of a three-phase field assisted BLDC generator. {yields} Confirm the accuracy of the predicted flux-linkage by 2-D FE analysis. {yields} Confirm the accuracy of the FE analysis results by coupling the FE and BE method. {yields} Control the output voltage to a desired level by control the amplitude of the I{sub f}. {yields} Compatible with any application that requires variable speed operation. -- Abstract: This paper describes the magnetic analysis and experiment of a three-phase field assisted brushless DC (BLDC) generator. Unlike conventional BLDC generators, the permanent magnet is replaced with an assisted field winding. The stator and rotor are constructed with two dependent magnetically sets, in which each stator set includes nine salient poles with coil windings, and the rotor comprises of six salient poles. Other pole combinations also are possible. This construction is similar to a homopolar inductor alternator. The DC current in the assisted field winding produces axial flux which makes the rotor magnetically polarized at its ends. The magnetic field flows axially through the rotor shaft and closes through the stator teeth and the machine housing. To evaluate the generator performance, two types of analysis, namely the numerical technique and the experimental study have been utilized. In the numerical analysis, 2-D finite element (FE) analysis has been carried out using a MagNet CAD package (Infolytica Corporation Ltd.), to confirm the accuracy of the predicted flux-linkage characteristics, whereas in the experimental study, a prototype BLDC generator was constructed for verifying the actual performance. Furthermore, the evaluation method based on a hybrid numerical method coupling the finite element (FE) analysis and boundary element (BE) method, has been carried out to confirm the accuracy of the 2-D FE analysis simulation results. It provides not only confirmations of the investigation in results

  2. Analysis of brushless DC generator incorporating an axial field coil

    International Nuclear Information System (INIS)

    Highlights: → Magnetic analysis and experiment of a three-phase field assisted BLDC generator. → Confirm the accuracy of the predicted flux-linkage by 2-D FE analysis. → Confirm the accuracy of the FE analysis results by coupling the FE and BE method. → Control the output voltage to a desired level by control the amplitude of the If. → Compatible with any application that requires variable speed operation. -- Abstract: This paper describes the magnetic analysis and experiment of a three-phase field assisted brushless DC (BLDC) generator. Unlike conventional BLDC generators, the permanent magnet is replaced with an assisted field winding. The stator and rotor are constructed with two dependent magnetically sets, in which each stator set includes nine salient poles with coil windings, and the rotor comprises of six salient poles. Other pole combinations also are possible. This construction is similar to a homopolar inductor alternator. The DC current in the assisted field winding produces axial flux which makes the rotor magnetically polarized at its ends. The magnetic field flows axially through the rotor shaft and closes through the stator teeth and the machine housing. To evaluate the generator performance, two types of analysis, namely the numerical technique and the experimental study have been utilized. In the numerical analysis, 2-D finite element (FE) analysis has been carried out using a MagNet CAD package (Infolytica Corporation Ltd.), to confirm the accuracy of the predicted flux-linkage characteristics, whereas in the experimental study, a prototype BLDC generator was constructed for verifying the actual performance. Furthermore, the evaluation method based on a hybrid numerical method coupling the finite element (FE) analysis and boundary element (BE) method, has been carried out to confirm the accuracy of the 2-D FE analysis simulation results. It provides not only confirmations of the investigation in results but also exact illustration for

  3. Arc Behaviours in Vacuum Interrupters with Axial Magnetic Field Electrodes

    Institute of Scientific and Technical Information of China (English)

    WANG Zhongyi; ZHENG Yuesheng; LIU Zhiyuan; CHENG Shaoyong

    2008-01-01

    To improve the limiting current interruption capability and minimizing vacuum interrupter with axial magnetic field (AMF) electrodes,it is significant to investigate the vacuum arc behaviours between the contacts.AMF distributions of the slot type electrodes were studied by both numerical analysis and experiments. Furthermore,the behaviours of vacuum arcs for different parameters of the slot type AMF electrodes were investigated by using high-speed CCD camera.The influences of gap distance,contact diameter and phase shift time between AMF and arc current on the vacuum arc were investigated.The results provide a reference for research and development of vacuum interrupters with slot type or other types of AMF electrode.

  4. High temperature superconducting axial field magnetic coupler: realization and test

    Science.gov (United States)

    Belguerras, L.; Mezani, S.; Lubin, T.; Lévêque, J.; Rezzoug, A.

    2015-09-01

    Contactless torque transmission through a large airgap is required in some industrial applications in which hermetic isolation is necessary. This torque transmission usually uses magnetic couplers, whose dimension strongly depends on the airgap flux density. The use of high temperature superconducting (HTS) coils to create a strong magnetic field may constitute a solution to reduce the size of the coupler. It is also possible to use this coupler to replace a torque tube in transmitting the torque produced by a HTS motor to its load. This paper presents the detailed construction and tests of an axial field HTS magnetic coupler. Pancake coils have been manufactured from BSCCO tape and used in one rotor of the coupler. The second rotor is mainly composed of NdFeB permanent magnets. Several tests have been carried out showing that the constructed coupler is working properly. A 3D finite element (FE) model of the studied coupler has been developed. Airgap magnetic field and torque measurements have been carried out and compared to the FE results. It has been shown that the measured and the computed quantities are in satisfactory agreement.

  5. Axial Magnetic Field Effect on Taylor-Couette Flow

    Directory of Open Access Journals (Sweden)

    Sofiane ABERKANE

    2015-01-01

    Full Text Available This study is interested in the effect of an axial magnetic field imposed on incompressible flow of electrically conductive fluid between two horizontal coaxial cylinders. The imposed magnetic field is assumed uniform and constant. The effect of heat generation due to viscous dissipation is also taken into account. The inner and outer cylinders are maintained at different uniform temperatures. The movement of the fluid is due to rotation of the cylinder with a constant speed. An exact solution of the equations governing the flow was obtained in the form of Bessel functions. A finite difference implicit scheme was used in the numerical solution. The velocity and temperature distributions were obtained with and without the magnetic field. The results show that for different values of the Hartmann number, the velocity between the two cylinders decreases as the Hartmann number increases. Also, it is found that by increasing the Hartmann number, the average Nusselt number decreases. On the other hand, the Hartmann number does not affect the temperature.

  6. Atomic Beam Laser Spectrometer for In-field Isotopic Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Alonso [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Actinide Analytical Chemistry Group

    2016-06-22

    This is a powerpoint presentation for the DTRA quarterly program review that goes into detail about the atomic beam laser spectrometer for in-field isotopic analysis. The project goals are the following: analysis of post-detonation debris, determination of U and Pu isotopic composition, and fieldable prototype: < 2ft3, < 1000W.

  7. Commissioning of the magnetic field in the ATLAS muon spectrometer

    CERN Document Server

    Arnaud, M; Bergsma, F; Bobbink, G; Bruni, A; Chevalier, L; Ennes, P; Fleischmann, P; Fontaine, M; Formica, A; Gautard, V; Groenstege, H; Guyot, C; Hart, R; Kozanecki, W; Iengo, P; Legendre, M; Nikitina, T; Perepelkin, E; Ponsot, P; Richardson, A; Vorozhtsov, A; Vorozthsov, S

    2008-01-01

    ATLAS is a general-purpose detector at the 14 TeV proton-proton Large Hadron Collider at CERN. The muon spectrometer will operate in the magnetic field provided by a large, eight-coil barrel toroid magnet bracketed by two smaller toroidal end-caps. The toroidal field is non-uniform, with an average value of about 0.5 T in the barrel region, and is monitored using three-dimensional Hall sensors which must be accurate to 1 mT. The barrel coils were installed in the cavern from 2004 to 2006, and recently powered up to their nominal current. The Hall-sensor measurements are compared with calculations to validate the magnetic models, and used to reconstruct the position and shape of the coil windings. Field perturbations by the magnetic materials surrounding the muon spectrometer are found in reasonable agreement with finite-element magnetic-field simulations.

  8. Linear electric field time-of-flight ion mass spectrometer

    Science.gov (United States)

    Funsten, Herbert O.; Feldman, William C.

    2008-06-10

    A linear electric field ion mass spectrometer having an evacuated enclosure with means for generating a linear electric field located in the evacuated enclosure and means for injecting a sample material into the linear electric field. A source of pulsed ionizing radiation injects ionizing radiation into the linear electric field to ionize atoms or molecules of the sample material, and timing means determine the time elapsed between ionization of atoms or molecules and arrival of an ion out of the ionized atoms or molecules at a predetermined position.

  9. Survey results for oblique field magnetic flux leakage survey in comparison to axial field

    Energy Technology Data Exchange (ETDEWEB)

    Simek, James [T.D. Williamson, Inc., Tulsa, OK (United States)

    2012-07-01

    Pipeline operators worldwide have implemented integrity management programs in an effort to improve operation and maintenance efficiency along with continued safe operation of pipeline systems. Several types of monitoring and data collection activities are incorporated into these programs, with in line inspection (ILI) tools providing data for detection and quantification of features that may impact the integrity of the pipeline system. Magnetic flux leakage (MFL) ILI tools are among the most widely used in pipeline systems. Primarily used for metal loss detection and quantification, these tools are extremely robust, performing successfully in the harsh environments found in operating pipelines, with the majority of MFL tools in service today relying upon axially oriented magnetic fields. For feature classes whose principal axis is aligned parallel to the pipe axis, the use of an axially applied magnetic field may quite often result in decreased performance due to difficulties in detection and sizing. Through the use of fields applied either perpendicular or in an oblique direction to the principal axis, the magnetic leakage levels generated at feature locations are increased, providing usable signal levels. When used concurrently with an axially oriented magnetizer, an obliquely applied magnetic field may provide the ability to detect, quantify, or otherwise aid in discrimination of volumetric versus non-volumetric features. Providing the ability to collect both of these data sets in a single survey would allow operators to minimize the number of surveys required to address all categories of metal loss features that may be present within pipeline systems. This paper will discuss some of the variables that affect detection and sizing of metal loss zones with respect to the applied field direction, including graphs and tables to quantify the effects of angular displacement for specific feature shapes. Several classes of features have been chosen for evaluation

  10. Axial distribution of absorbed doses in fast neutron field at the RB reactor

    International Nuclear Information System (INIS)

    The coupled fast thermal system CFTS at the RB reactor is created for obtaining fast neutron fields. The axial distribution of fast neutron flux density in its second configuration (CFTS-2) is measured. The axial distribution of absorbed doses is computed on the basis of mentioned experimental results. At the end these experimental and computed results are given. (Author)

  11. An active pixels spectrometers for neutronic fields metrology

    International Nuclear Information System (INIS)

    The fundamental metrology is responsible for the sustainability of the measurement systems and handles to supply the reference standards. Concerning the metrology of ionizing radiations and, in particular the neutron metrology, detectors standards are used to characterize reference fields, in terms of energy and fluence. The dosimeters or particle detectors are calibrated on these reference fields. This thesis presents the development of a neutron spectrometer neutron candidate to the status of primary standard for the characterization of neutron fields in the range from 5 to 20 MeV. The spectrometer uses the recoil proton telescope as detection principle; the CMOS technology, through three sensor positions, is taking advantage to realize the tracking of protons. A Si(Li) detector handles the measure of the residual proton energy. The device simulations, realized under MCNPX, allow to estimate its performances and to validate the neutron energy reconstruction. An essential step of characterization of the telescope elements and in particular of CMOS sensors is also proposed to guarantee the validity of posterior experimental measurements. The tests realized as well in mono-energy fields as in radionuclide source show the very good performances of the system. The quantification of uncertainties indicates an energy estimation with 1.5 % accuracy and a resolution of less than 6 %. The fluence measurement is performed with an uncertainty about 4 to 6%. (author)

  12. Field mapping of the Hall A high-resolution spectrometers of the Thomas Jefferson National Accelerator Facility (Jefferson Lab)

    CERN Document Server

    Vernin, P; Fonvieille, H; Quéméner, G; Le Rose, J J; Hogan, J; Vlahovic, B; Billan, J

    2000-01-01

    This paper reports on the magnetic field mapping performed on the HRS spectrometers of Hall A, which are of QQDQ type. The dipoles were measured with a set of Hall probes in the symmetry mid-plane. The quadrupoles were measured inside their whole volume by a set of axially segmented rotating coils. High accuracy has been reached in both cases. Dipoles and quadrupoles were measured for a set of ex citation currents covering the operating momentum range of the HRS: 0.5-4 GeV/c. The main results on field determination are presented.

  13. Axial shock wave heating of reversed-field theta-pinch plasmas

    International Nuclear Information System (INIS)

    Reversed-field theta pinches are known to contract rapidly in the axial direction soon after the radial implosion. Under certain conditions the axial implosion can be quite strong. A model is described which simulates both the radial and axial implosions. Among the important features included are realistic plasma density profiles, and current-driven anomalous transport. Given input parameters such as initial fill pressure, bias magnetic field, coil size, applied voltage (or electric field) and compression magnetic field, the model predicts the final plasma temperature, density, radial and axial dimensions, trapped magnetic flux and fraction of particles trapped within the separatrix. The results indicate very strong axial shock heating for high bias field, which leads to temperatures up to several times that predicted for simple field-free plasmas. The model is applied to parameters charcteristic of two recent experiments, and several features of the calculated results are shown to be consistent with experimental observations. It is also applied to a fusion reactor scale plasma: as a result of strong axial shock heating, the model predicts that fusion ignition (e.g., a temperature of 8 keV) can be achieved without resort to large electric field or large magnetic compression

  14. Principal parametric resonance of axially accelerating rectangular thin plate in magnetic field

    Institute of Scientific and Technical Information of China (English)

    胡宇达; 张金志

    2013-01-01

    Nonlinear parametric vibration and stability is investigated for an axially accelerating rectangular thin plate subjected to parametric excitations resulting from the axial time-varying tension and axial time-varying speed in the magnetic field. Consid-ering geometric nonlinearity, based on the expressions of total kinetic energy, potential energy, and electromagnetic force, the nonlinear magneto-elastic vibration equations of axially moving rectangular thin plate are derived by using the Hamilton principle. Based on displacement mode hypothesis, by using the Galerkin method, the nonlinear para-metric oscillation equation of the axially moving rectangular thin plate with four simply supported edges in the transverse magnetic field is obtained. The nonlinear principal parametric resonance amplitude-frequency equation is further derived by means of the multiple-scale method. The stability of the steady-state solution is also discussed, and the critical condition of stability is determined. As numerical examples for an axially moving rectangular thin plate, the influences of the detuning parameter, axial speed, axial tension, and magnetic induction intensity on the principal parametric resonance behavior are investigated.

  15. Flow field determination at axial pump impeller tip section

    International Nuclear Information System (INIS)

    In most applications the principal limitation on the performance of an axial-flow pump is its cavitation-free operating range, characterized by the nett positive suction head (NPSH). The adverse effects of cavitation are not restricted to impaired performance; noise and vibration levels tend to increase and mechanical integrity of components can be jeopardised, sometimes severely. Cavitation may occur in the inlet region or, in some instances, in the stator blades; however the most usual source of cavitation occurrence is the impeller blading, specifically the tip section

  16. Seiberg Witten Map and the Axial Anomaly in Noncommutative Field Theory

    OpenAIRE

    Banerjee, Rabin; Ghosh, Subir

    2001-01-01

    Using the point-splitting regularisation, we calculate the axial anomaly in an arbitrary even dimensional Non-Commutative (NC) field theory. Our result is (star) gauge invariant in its {\\it unintegrated} form, to the leading order in the NC parameter. Exploiting the Seiberg Witten map, this result gets transformed to the familiar Adler-Bell-Jackiw anomaly in ordinary space-time. Furthermore, using this map, we derive an expression for the unintegrated axial anomaly for constant fields in NC s...

  17. The Influence of the Axial Magnetic Field Upon-the Coaxial Plasma Gun Parameters

    International Nuclear Information System (INIS)

    This study concerns with the influence of an applied axial magnetic field upon the electrical parameters of a coaxial plasma gun device. The experimental results are investigated with 0.5 KJ plasma gun device operated with argon gas at a pressure of 3.5 Torr. An axial time independent magnetic field with intensity of 550 G is introduced along the plasma current sheath axial region, within the annular space between the two coaxial electrodes. From the measurements of the discharge current I(t) and the voltage V(t), the electrical discharge parameters of the plasma gun device and the plasma current sheath implosion velocity are estimated, in normal mode of plasma gun operation and in the mode of presence external axial magnetic field. A comparison between these two modes is studied

  18. Neutron dosimetry in mixed fields with monoblock neutron spectrometer

    International Nuclear Information System (INIS)

    Full text: The multi-sphere method of neutron spectrometry or namely Bonner spheres neutron spectrometry is currently playing an increasing role in the mixed radiation field measurements. The growing popularity of this methodology is caused by its relative availability, simplicity of measurement in a wide energy range, high sensitivity and satisfactory gamma-ray suppression. These qualities allow the usage of multi-sphere neutron spectrometers for adequate characterization of neutron field, particularly reliable measurements of neutron dose rate. However, the main difficulties in the application of this kind of neutron detector are the perturbation of the neutron field, caused by the detector itself, and the complex procedure required for unfolding the neutron spectrum. Furthermore, it is necessary to perform a relatively high number of measurements, one for each spherical moderator (as a rule, 5-7 pieces). This in turn may require a dedicated source monitoring system, otherwise significant errors may occur. These requirements hamper the application of the multi-sphere spectrometry method to pulsed neutron sources, for example. Other difficulties occur in the characterization of reactor neutron beams, in case the beam diameter is smaller than those of the spherical moderators. In this situation it is necessary to carry out a beam scanning and integrate the acquired data. To improve the methodology of neutron field parameter measurement the Monoblock Neutron Spectrometer (MNS) has been developed recently. The basic idea of the novel detector is to determine the neutron energy spectrum by unfolding a set of count rates from thermal neutron detectors located at different depths in the common polyethylene moderator. The unfolding algorithms for neutron spectrum and neutron dose rates have been specifically improved for operation with MNS. The testing results with well-know neutron reference fields and reactor neutron beam are presented. The application of MNS for

  19. Field transportable beta spectrometer. Innovative technology summary report

    International Nuclear Information System (INIS)

    The objective of the Large-Scale Demonstration Project (LSDP) is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory-East (ANL) Chicago Pile-5 Test Reactor (CP-5). The purpose of the LSDP is to demonstrate that by using innovative and improved deactivation and decommissioning (D and D) technologies from various sources, significant benefits can be achieved when compared to baseline D and D technologies. One such capability being addressed by the D and D Focus Area is rapid characterization for facility contaminants. The technology was field demonstrated during the period January 7 through January 9, 1997, and offers several potential benefits, including faster turn-around time, cost reduction, and reduction in secondary waste. This report describes a PC controlled, field-transportable beta counter-spectrometer which uses solid scintillation coincident counting and low-noise photomultiplier tubes to count element-selective filters and other solid media. The dry scintillation counter used in combination with an element-selective technology eliminates the mess and disposal costs of liquid scintillation cocktails. Software in the instrument provides real-time spectral analysis. The instrument can detect and measure Tc-99, Sr-90, and other beta emitters reaching detection limits in the 20 pCi range (with shielding). Full analysis can be achieved in 30 minutes. The potential advantages of a field-portable beta counter-spectrometer include the savings gained from field generated results. The basis for decision-making is provided with a rapid turnaround analysis in the field. This technology would be competitive with the radiometric analysis done in fixed laboratories and the associated chain of custody operations

  20. Field transportable beta spectrometer. Innovative technology summary report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-01

    The objective of the Large-Scale Demonstration Project (LSDP) is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory-East (ANL) Chicago Pile-5 Test Reactor (CP-5). The purpose of the LSDP is to demonstrate that by using innovative and improved deactivation and decommissioning (D and D) technologies from various sources, significant benefits can be achieved when compared to baseline D and D technologies. One such capability being addressed by the D and D Focus Area is rapid characterization for facility contaminants. The technology was field demonstrated during the period January 7 through January 9, 1997, and offers several potential benefits, including faster turn-around time, cost reduction, and reduction in secondary waste. This report describes a PC controlled, field-transportable beta counter-spectrometer which uses solid scintillation coincident counting and low-noise photomultiplier tubes to count element-selective filters and other solid media. The dry scintillation counter used in combination with an element-selective technology eliminates the mess and disposal costs of liquid scintillation cocktails. Software in the instrument provides real-time spectral analysis. The instrument can detect and measure Tc-99, Sr-90, and other beta emitters reaching detection limits in the 20 pCi range (with shielding). Full analysis can be achieved in 30 minutes. The potential advantages of a field-portable beta counter-spectrometer include the savings gained from field generated results. The basis for decision-making is provided with a rapid turnaround analysis in the field. This technology would be competitive with the radiometric analysis done in fixed laboratories and the associated chain of custody operations.

  1. Laboratory Calibration of a Field Imaging Spectrometer System

    Directory of Open Access Journals (Sweden)

    Qingxi Tong

    2011-02-01

    Full Text Available A new Field Imaging Spectrometer System (FISS based on a cooling area CCD was developed. This paper describes the imaging principle, structural design, and main parameters of the FISS sensor. The FISS was spectrally calibrated with a double grating monochromator to determine the center wavelength and FWHM of each band. Calibration results showed that the spectral range of the FISS system is 437–902 nm, the number of channels is 344 and the spectral resolution of each channel is better than 5 nm. An integrating sphere was used to achieve absolute radiometric calibration of the FISS with less than 5% calibration error for each band. There are 215 channels with signal to noise ratios (SNRs greater than 500 (62.5% of the bands. The results demonstrated that the FISS has achieved high performance that assures the feasibility of its practical use in various fields.

  2. Study and construction of a {beta}-spectrometer of uniform axial magnetic field fitted with a {beta}-{gamma} coincidence selector. Study of the {beta} spectra of {sup 32}P, {sup 203}Hg, {sup 198}Au. Measurement of the conversion coefficients of {sup 203}Ti and of {sup 198}Hg; Etude et realisation d'un spectrometre-{beta} a champ magnetique axial uniforme, muni d'un selecteur de coincidence {beta}-{gamma}. Etude des spectres {beta} du {sup 32}p, {sup 203}Hg, {sup 198}Au. Mesure des coefficients de conversion du {sup 203}Ti et du {sup 198}Hg

    Energy Technology Data Exchange (ETDEWEB)

    Parsignault, D. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-06-01

    In the first part is given the principle of the beta spectrometer with uniform axial field using systematically the idea of caustics. The apparatus is described and its properties compared to those deduced from trajectory calculations. The {beta}-ray and {gamma}-ray detectors and the device for selecting coincidences with a 2 {tau} resolution of 5 nanoseconds are also presented. In the second part, the spectrometer is used for studying reference elements and the most accurate results are confirmed. The {beta} spectrum of {sup 60}Co has a statistical form with an accuracy of 1 per cent; the maximum energy E{sub 0} is 316.5 {+-} 1.5 keV. That of the 7/2 + {yields} 11/2 transition for {sup 137}Cs has a unique form, once forbidden. E{sub 0}= 522 {+-} 3 keV. Conversion coefficients {alpha}{sub k} = 96 {+-} 1 X 10{sup -3} {alpha}L + M + N = 20.9 {+-} 0.5 X 10{sup -3}. The two {beta} spectra of {sup 59}Fe, separated by coincidence with the gamma, have the statistical form E{sub 0} = 462 {+-} 2 keV (55.1 + 0,3 per cent) and E{sub 1} = 275 {+-} 4 keV (44.9 {+-} 0.3 per cent). It is then verified whether the l selection rule is apparent in the shape of the phosphorus 32 beta spectrum. It is found in fact that it is not of statistical shape and its shape coefficient is determined. For a theoretical interpretation it is necessary to have better approximations than those generally used and this interpretation will not be unique. This work has also made it possible to show that the source contains a small proportion of {sup 33}P. The study of the {sup 203}Hg {beta} spectrum followed by the 279 keV gamma spectrum is designed to determine the conversion coefficients. The interior spectrum of gold 198 is not of statistical shape either. The form coefficient is determined together with the conversion coefficients which are in slight disagreement with those calculated by Rose or Sliv. An interpretation of the spectrum is put forward which proposes an imperfect compensation for the

  3. Research on an Axial Magnetic-Field-Modulated Brushless Double Rotor Machine

    OpenAIRE

    Bin Yu; Chengde Tong; Zhiyi Song; Jingang Bai; Ping Zheng

    2013-01-01

    Double rotor machine, an electronic continuously variable transmission, has great potential in application of hybrid electric vehicles (HEVs), wind power and marine propulsion. In this paper, an axial magnetic-field-modulated brushless double rotor machine (MFM-BDRM), which can realize the speed decoupling between the shaft of the modulating ring rotor and that of the permanent magnet rotor is proposed. Without brushes and slip rings, the axial MFM-BDRM offers significant advantages such as e...

  4. Axial acoustic radiation force on a sphere in Gaussian field

    International Nuclear Information System (INIS)

    Based on the finite series method, the acoustical radiation force resulting from a Gaussian beam incident on a spherical object is investigated analytically. When the position of the particles deviating from the center of the beam, the Gaussian beam is expanded as a spherical function at the center of the particles and the expanded coefficients of the Gaussian beam is calculated. The analytical expression of the acoustic radiation force on spherical particles deviating from the Gaussian beam center is deduced. The acoustic radiation force affected by the acoustic frequency and the offset distance from the Gaussian beam center is investigated. Results have been presented for Gaussian beams with different wavelengths and it has been shown that the interaction of a Gaussian beam with a sphere can result in attractive axial force under specific operational conditions. Results indicate the capability of manipulating and separating spherical spheres based on their mechanical and acoustical properties, the results provided here may provide a theoretical basis for development of single-beam acoustical tweezers

  5. Field neutron spectrometer using 3He, TEPC, and multisphere detectors

    International Nuclear Information System (INIS)

    Since the last DOE Neutron Dosimetry Workshop, there have been a number of changes in radiation protection standards proposed by national and international advisory bodies. These changes include: increasing quality factors for neutrons by a factor of two, defining quality factors as a function of lineal energy rather than linear energy transfer (see ACCRUE-40; Joint Task Group 1986), and adoption of effective dose equivalent methodologies. In order to determine the effects of these proposed changes, it is necessary to know the neutron energy spectrum in the work place. In response to the possible adoption of these proposals, the Department of Energy (DOE) initiated a program to develop practical neutron spectrometry systems for use by health physicists. One part of this program was the development of a truly portable, battery operated liquid scintillator spectrometer using proprietary electronics developed at Lawrence Livermore National Laboratory (LLNL); this instrument will be described in the following paper. The second part was the development at PNL of a simple transportable spectrometer based on commercially available electronics. This open-quotes field neutron spectrometerclose quotes described in this paper is intended to be used over a range of neutron energies extending from thermal to 20 MeV

  6. OLYMPEX Counterflow Spectrometer and Impactor Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Poellot, Michael [Univ. of North Dakota, Grand Forks, ND (United States)

    2016-07-01

    The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility’s ARM Aerial Facility (AAF) Counterflow Spectrometer and Impactor (CSI) probe was flown on the University of North Dakota Cessna Citation research aircraft during the Olympic Mountain Experiment (OLYMPEX). The field campaign took place from November 12 through December 19, 2015, over the Olympic Mountains and coastal waters of Washington State as part of a National Aeronautics and Space Administration (NASA) Global Precipitation Measurement (GPM) validation campaign. The CSI was added to the Citation instrument suite to support the NASA Aerosol-Cloud Ecosystem (ACE) satellite program and flights of the NASA Lockheed Earth Resources (ER-2) aircraft. ACE funded extra ER-2 flights to focus on clouds that are weakly precipitating, which are also of interest to the DOE Atmospheric System Research (ASR) program.

  7. Toroidal linear force-free magnetic fields with axial symmetry

    Science.gov (United States)

    Vandas, M.; Romashets, E.

    2016-01-01

    Aims: Interplanetary magnetic flux ropes are often described as linear force-free fields. To account for their curvature, toroidal configurations must be used. The aim is to find an analytic description of a linear force-free magnetic field of the toroidal geometry in which the cross section of flux ropes can be controlled. Methods: The solution is found as a superposition of fields given by linear force-free cylinders tangential to a generating toroid. The cylindrical field is expressed in a series of terms that are not all cylindrically symmetric. Results: We found the general form of a toroidal linear force-free magnetic field. The field is azimuthally symmetric with respect to the torus axis. It depends on a set of coefficients that enables controlling the flux rope shape (cross section) to some extent. By varying the coefficients, flux ropes with circular and elliptic cross sections were constructed. Numerical comparison suggests that the simple analytic formula for calculating the helicity in toroidal flux ropes of the circular cross section can be used for flux ropes with elliptic cross sections if the minor radius in the formula is set to the geometric mean of the semi-axes of the elliptic cross section.

  8. Tangential Velocity Profile for Axial Flow Through Two Concentric Rotating Cylinders with Radial Magnetic Field

    Directory of Open Access Journals (Sweden)

    Girishwar Nath

    1970-10-01

    Full Text Available A closed form solution of the Navier-Stokes equations has been obtained in the case of steady axisymmetric flow of an incompressible electrically conducting viscous fluid between two concentric rotating cylinders composed of an insulating material under the influence of radial magnetic field. It has been found that the velocity components are less than those of the classical hydrodynamic case. In the presence of the magnetic field, the tangential velocity becomes fully developed in a smaller axial distance than in the absence of the magnetic field. For small Reynolds number, the fully developed tangential velocity is achieved in a small axial distance, but it requires greater axial distance for large Reynolds number.

  9. Axial-field permanent magnet motors for electric vehicles

    Science.gov (United States)

    Campbell, P.

    1981-01-01

    The modelling of an anisotropic alnico magnet for the purpose of field computation involves assigning a value for the material's permeability in the transverse direction. This is generally based upon the preferred direction properties, being all that are easily available. By analyzing the rotation of intrinsic magnetization due to the self demagnetizing field, it is shown that the common assumptions relating the transverse to the preferred direction are not accurate. Transverse magnetization characteristics are needed, and these are given for Alnico 5, 5-7, and 8 magnets, yielding appropriate permeability values.

  10. Nongeocentric axial dipole field behavior during the Mono Lake excursion

    Science.gov (United States)

    Negrini, Robert M.; McCuan, Daniel T.; Horton, Robert A.; Lopez, James D.; Cassata, William S.; Channell, James E. T.; Verosub, Kenneth L.; Knott, Jeffrey R.; Coe, Robert S.; Liddicoat, Joseph C.; Lund, Steven P.; Benson, Larry V.; Sarna-Wojcicki, Andrei M.

    2014-04-01

    A new record of the Mono Lake excursion (MLE) is reported from the Summer Lake Basin of Oregon, USA. Sediment magnetic properties indicate magnetite as the magnetization carrier and imply suitability of the sediments as accurate recorders of the magnetic field including relative paleointensity (RPI) variations. The magnitudes and phases of the declination, inclination, and RPI components of the new record correlate well with other coeval but lower resolution records from western North America including records from the Wilson Creek Formation exposed around Mono Lake. The virtual geomagnetic pole (VGP) path of the new record is similar to that from another high-resolution record of the MLE from Ocean Drilling Program (ODP) Site 919 in the Irminger Basin between Iceland and Greenland but different from the VGP path for the Laschamp excursion (LE), including that found lower in the ODP-919 core. Thus, the prominent excursion recorded at Mono Lake, California, is not the LE but rather one that is several thousands of years younger. The MLE VGP path contains clusters, the locations of which coincide with nonaxial dipole features found in the Holocene geomagnetic field. The clusters are occupied in the same time progression by VGPs from Summer Lake and the Irminger Basin, but the phase of occupation is offset, a behavior that suggests time-transgressive decay and return of the principal field components at the beginning and end of the MLE, respectively, leaving the nonaxial dipole features associated with the clusters dominant during the excursion.

  11. A flat-field XUV spectrometer with 155 mm incidence distance

    International Nuclear Information System (INIS)

    Using a ray-tracing code, A flat-field grazing-incidence spectrometer with 155 mm incident distance was designed. This is different from the conventional design for a flat-field grazing-incidence spectrometer. This spectrometer has good spectral resolution as well as smaller size and improved flexibility. The spectrum covers wavelength ranges of 4 - 40nm and the spectral resolution is 0.01 nm

  12. Axial magnetic field generation by intense circularly polarized laser pulses in underdense plasmas

    International Nuclear Information System (INIS)

    Axial magnetic field generation by intense circularly polarized laser beams in underdense plasmas has been studied with three-dimensional particle-in-cell simulations and by means of theoretical analysis. Comparisons between analytical models and simulation results have identified an inverse Faraday effect as the main mechanism of the magnetic field generation in inhomogeneous plasmas. The source of azimuthal nonlinear currents and of the axial magnetic field depends on the transverse inhomogeneities of the electron density and laser intensity. The fields reach a maximum strength of several tens of megagauss for laser pulses undergoing relativistic self-focusing and channeling in moderately relativistic regime. Ultrarelativistic laser conditions inhibit magnetic field generation by directly reducing a source term and by generating fully evacuated plasma channels.

  13. Influence of induced axial magnetic field on plasma dynamics and radiative characteristics of Z pinches

    International Nuclear Information System (INIS)

    The influence of an induced axial magnetic field on plasma dynamics and radiative characteristics of Z pinches is investigated. An axial magnetic field was induced in a novel Z-pinch load: a double planar wire array with skewed wires (DPWAsk), which represents a planar wire array in an open magnetic configuration. The induced axial magnetic field suppressed magneto-Rayleigh-Taylor (MRT) instabilities (with m = 0 and m = 1 instability modes) in the Z-pinch plasma. The influence of the initial axial magnetic field on the structure of the plasma column at stagnation was manifested through the formation of a more uniform plasma column compared to a standard double planar wire array (DPWA) load [V. L. Kantsyrev et al., Phys. Plasmas 15, 030704 (2008)]. The DPWAsk load is characterized by suppression of MRT instabilities and by the formation of the sub-keV radiation pulse that occurs before the main x-ray peak. Gradients in plasma parameters along the cathode-anode gap were observed and analyzed for DPWAsk loads made from low atomic number Z (Al) and mid-Z (brass) wires.

  14. Parallax error in long-axial field-of-view PET scanners—a simulation study

    Science.gov (United States)

    Schmall, Jeffrey P.; Karp, Joel S.; Werner, Matt; Surti, Suleman

    2016-07-01

    There is a growing interest in the design and construction of a PET scanner with a very long axial extent. One critical design challenge is the impact of the long axial extent on the scanner spatial resolution properties. In this work, we characterize the effect of parallax error in PET system designs having an axial field-of-view (FOV) of 198 cm (total-body PET scanner) using fully-3D Monte Carlo simulations. Two different scintillation materials were studied: LSO and LaBr3. The crystal size in both cases was 4  ×  4  ×  20 mm3. Several different depth-of-interaction (DOI) encoding techniques were investigated to characterize the improvement in spatial resolution when using a DOI capable detector. To measure spatial resolution we simulated point sources in a warm background in the center of the imaging FOV, where the effects of axial parallax are largest, and at several positions radially offset from the center. Using a line-of-response based ordered-subset expectation maximization reconstruction algorithm we found that the axial resolution in an LSO scanner degrades from 4.8 mm to 5.7 mm (full width at half max) at the center of the imaging FOV when extending the axial acceptance angle (α) from  ±12° (corresponding to an axial FOV of 18 cm) to the maximum of  ±67°—a similar result was obtained with LaBr3, in which the axial resolution degraded from 5.3 mm to 6.1 mm. For comparison we also measured the degradation due to radial parallax error in the transverse imaging FOV; the transverse resolution, averaging radial and tangential directions, of an LSO scanner was degraded from 4.9 mm to 7.7 mm, for a measurement at the center of the scanner compared to a measurement with a radial offset of 23 cm. Simulations of a DOI detector design improved the spatial resolution in all dimensions. The axial resolution in the LSO-based scanner, with α  =  ± 67°, was improved from 5.7 mm to 5.0 mm by

  15. HiFi-A new high field muon spectrometer at ISIS

    International Nuclear Information System (INIS)

    A new μSR spectrometer (HiFi) is being constructed at the ISIS pulsed muon source. The spectrometer is intended for measurements in longitudinal magnetic fields up to 5 T. Here we discuss various aspects of the design and future operation of the HiFi spectrometer. Detailed analysis of the detector design is presented, and results from tests on detector prototypes are compared to simulations. Potential applications of this spectrometer in the fields of condensed matter and chemistry are also discussed.

  16. HiFi-A new high field muon spectrometer at ISIS

    Energy Technology Data Exchange (ETDEWEB)

    Salman, Z., E-mail: z.salman1@physics.ox.ac.u [Clarendon Laboratory, Department of Physics, Oxford University, Parks Road, Oxford OX1 3PU (United Kingdom); ISIS Facility, Rutherford Appleton Laboratory, Chilton, Oxfordshire OX11 0QX (United Kingdom); Baker, P.J.; Blundell, S.J. [Clarendon Laboratory, Department of Physics, Oxford University, Parks Road, Oxford OX1 3PU (United Kingdom); Cottrell, S.P.; Giblin, S.R.; Hillier, A.D. [ISIS Facility, Rutherford Appleton Laboratory, Chilton, Oxfordshire OX11 0QX (United Kingdom); Holsman, B.H. [ISIS Project Engineering Group, Rutherford Appleton Laboratory, Chilton, Oxfordshire OX11 0QX (United Kingdom); King, P.J.C. [ISIS Facility, Rutherford Appleton Laboratory, Chilton, Oxfordshire OX11 0QX (United Kingdom); Lancaster, T. [Clarendon Laboratory, Department of Physics, Oxford University, Parks Road, Oxford OX1 3PU (United Kingdom); Lord, J.S.; McKenzie, I. [ISIS Facility, Rutherford Appleton Laboratory, Chilton, Oxfordshire OX11 0QX (United Kingdom); Nightingale, J. [ISIS Project Engineering Group, Rutherford Appleton Laboratory, Chilton, Oxfordshire OX11 0QX (United Kingdom); Pratt, F.L. [ISIS Facility, Rutherford Appleton Laboratory, Chilton, Oxfordshire OX11 0QX (United Kingdom); Scheuermann, R. [Laboratory for Muon Spin Spectroscopy, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland)

    2009-04-15

    A new muSR spectrometer (HiFi) is being constructed at the ISIS pulsed muon source. The spectrometer is intended for measurements in longitudinal magnetic fields up to 5 T. Here we discuss various aspects of the design and future operation of the HiFi spectrometer. Detailed analysis of the detector design is presented, and results from tests on detector prototypes are compared to simulations. Potential applications of this spectrometer in the fields of condensed matter and chemistry are also discussed.

  17. Accelerating field spectrometer for photons and electrons simultaneous measurement. Application to decay schemes study

    International Nuclear Information System (INIS)

    An original spectrometer was built to improve the measurement of the absolute emission intensities of radionuclides with converted low energy gamma transitions. In this spectrometer, the same Si(Li) detector simultaneously measures electrons and photons emitted by the studied radionuclide; an electrostatic field may be established between the source and the detector to modify the electrons energy. This field allows the electron and photon peaks to be separated, and the absorption and energy straggling by detector windows to be decreased. Special attention has been given to determine spectrometer efficiency calibration curves for electrons and photons. 147Nd and 133Ba were used to test the spectrometer improvement and the method used

  18. The Influence of the Axial Magnetic Field Upon- the Coaxial Plasma Gun Parameters

    International Nuclear Information System (INIS)

    This study concerns with the influence of an applied axial magnetic field upon the electrical parameters and on the brightness (luminance) of argon plasma. The brightness was measured by with a photomultiplier type of IP28 RCA. The experimental results are investigated with plasma gun device operated with argon gas at a pressure of 3.5 Torr. An axial time independent magnetic field with intensity of 550 G is introduced along the plasma current sheath axial region, within the annular space between the two coaxial electrodes. From the measurements of the discharge current I(t) and the voltage V(t), the electrical discharge parameters of the plasma gun device and the plasma current sheath implosion velocity are estimated, in normal mode of plasma gun operation and in the mode of presence external axial magnetic field. A comparison between these two modes is studied. It was found that the thickness of skin-layer δ about 0.01 cm and the wavelength λ, of the perturbation about 1.3 cm i.e. the instability has been satisfied. The growth rate γ of the instability about 106 sec-1. (author)

  19. SUPERFISH 1 program for calculation of electromagnetic fields of axially-symmetric resonators

    International Nuclear Information System (INIS)

    The possibilities, structure and guidance to use the package of the SUPERFISH 1 programs computing the eigenfrequencies and fields of axial-symmetric resonators. The package has been designed to be applied at the ICL 1906A computer. The characteristic time of computing one frequency and corresponding fields is 20 s with the frequency being computed to an accuracy of 10-3. The computation time is independent of the complexity of the resonator geometry

  20. On Axially Symmetric Space-Times Admitting Homothetic Vector Fields in Lyra's Geometry

    CERN Document Server

    Gad, Ragab M

    2016-01-01

    This paper investigates axially symmetric space-times which admit a homothetic vector field based on Lyra's geometry. The cases when the displacement vector is function of $t$ and when it is constant are studied. In the context of this geometry, we find and classify the solutions of the Einstein's field equations (EFE) for the space-time under consideration which display a homothetic symmetry.

  1. One-dimensional magnetohydrodynamics of a cylindrical liner imploded by an azimuthal magnetic field and compressing an axial field

    Energy Technology Data Exchange (ETDEWEB)

    Hamann, F., E-mail: franck.hamann@cea.fr; Combis, P.; Videau, L. [CEA, DAM, DIF, F-91297 Arpajon (France)

    2015-08-15

    The one-dimensional magnetohydrodynamics of a plasma cylindrical liner is addressed in the case of a two components magnetic field. The azimuthal component is responsible for the implosion of the liner and the axial field is compressed inside the liner. A complete set of analytical profiles for the magnetic field components, the density, and the local velocity are proposed at the scale of the liner thickness. Numerical simulations are also presented to test the validity of the analytical formulas.

  2. One-dimensional magnetohydrodynamics of a cylindrical liner imploded by an azimuthal magnetic field and compressing an axial field

    International Nuclear Information System (INIS)

    The one-dimensional magnetohydrodynamics of a plasma cylindrical liner is addressed in the case of a two components magnetic field. The azimuthal component is responsible for the implosion of the liner and the axial field is compressed inside the liner. A complete set of analytical profiles for the magnetic field components, the density, and the local velocity are proposed at the scale of the liner thickness. Numerical simulations are also presented to test the validity of the analytical formulas

  3. Vacuum arcing behavior between transverse magnetic field contacts subjected to variable axial magnetic field

    Science.gov (United States)

    Ma, Hui; Wang, Jianhua; Liu, Zhiyuan; Geng, Yingsan; Wang, Zhenxing; Yan, Jing

    2016-06-01

    The objective of this work is to reveal the effects of an axial magnetic field (AMF) on the vacuum arc characteristics between transverse magnetic field (TMF) contacts. These vacuum arc characteristics include the vacuum arcing behavior and the arc voltage waveform. In the experiments, an external AMF was applied to a pair of TMF contacts. The external AMF flux density BAMF can be adjusted from 0 to 110 mT. The arc current in the tests varied over a range from 0 to 20 kA rms at 45 Hz. The contact material was CuCr25 (25% Cr). A high-speed charge-coupled device video camera was used to record the vacuum arc evolution. The experimental results show that the application of the AMF effectively reduces the TMF arc voltage noise component and reduces the formation of liquid metal drops between the contacts. The diffuse arc duration increases linearly with increasing AMF flux density, but it also decreases linearly with increasing arc current under application of the external AMF. The results also indicate that the diffuse arc duration before the current zero is usually more than 1 ms under the condition that the value of the AMF per kiloampere is more than 2.0 mT/kA. Finally, under application of the AMF, the arc column of the TMF contacts may constrict and remain in the center region without transverse rotation. Therefore, the combined TMF-AMF contacts should be designed such that they guarantee that the AMF is not so strong as to oppose transverse rotation of the arc column.

  4. Axial preloading of a 20 TESLA prototype of a single turn Tokamak toroidal field coil

    International Nuclear Information System (INIS)

    An axial preloading system has been designed and built as part of the 0.06 scale prototype toroidal field (TF) magnet for the IGNITEX experiment. In the prototype TF coil, as in the full size IGNITEX tokamak, the peak stresses in the inner leg during discharge are made more isotropic (hence the von Mises stress intensity is lowered) through axial preloading. Although preliminary (nonpreloaded) tests of the TF magnet should produce fields as high as 15 T, preloading will permit demonstration of the high (20 T) on-axis magnetic field to be achieved in the IGNITEX device. The preloading system for the prototype is a hydraulic press capable of a load of 580 tons. The press is designed with a short stroke which takes the press from a condition of noncontact to full preloading. During the magnet's pulse and subsequent thermal growth, the hydraulic system of the press maintains the preload force

  5. Radiofrequency hydrogen ion source with permanent magnets providing axial magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Oikawa, Kohei, E-mail: oikawa@ecei.tohoku.ac.jp; Saito, Yuta; Komizunai, Shota; Takahashi, Kazunori; Ando, Akira [Department of Electrical Engineering, Tohoku University, Sendai 980-8579 (Japan)

    2014-02-15

    Uniform axial magnetic field of about 70 G is applied to a radiofrequency (rf) hydrogen ion source by arrays of permanent magnets. The plasma density and electron temperature downstream of the source and near the magnetic filter are compared with those in the previously described ion source, where the axial field has been applied by two solenoids. The source is operated at ∼350 kHz and above 10 kW rf power with a field-effect-transistor-based invertor power supply in 1.5 Pa hydrogen. The results show that the plasma density of ∼10{sup 19} m{sup −3} near the source exit and ∼10{sup 18} m{sup −3} near the magnetic filter can be obtained, which are higher than those with the solenoids.

  6. Partially conserved axial-vector current and model chiral field theories in nuclear physics

    International Nuclear Information System (INIS)

    We comment on the relation between the two standard approaches to chiral symmetry--namely, the current algebra/partially conserved axial-vector current approach and the chiral Lagrangian method--in a manner intended to clarify recent and probable future applications of this symmetry in nuclear physics. Specifically, we show that in explicit chiral field theories the canonical πN scattering amplitude does not have the famed ''Adler zero'' unless partial conservation of axial-vector current holds as an operator equation. This implies that there are a number of familiar chiral models in which the ''Adler self-consistency'' condition does not apply to the canonical pion field. Among the problems of current interest for which our remarks are relevant are the studies of the pion-nucleus optical potential, pion condensation, and the attempts to formulate a model field theory having both reasonable nuclear saturation and good low energy pion phenomenology

  7. Microwave generation from an axially extracted virtual cathode oscillator with a guide magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Kostov, K.G.; Nikolov, N.A. (Department of General Physics, Sofia University, Sofia 1126 (Bulgaria))

    1994-04-01

    The operation of a virtual cathode oscillator (vircator) with strong axial magnetic field has been experimentally studied. Depending on the cathode--anode gap and cathode diameter, the operating voltage varies from 200 kV up to 480 kV with 2--7 kA diode current. Microwave emission is produced by the oscillating virtual cathode. The central microwave frequency follows the beam plasma frequency. It varies by 11.5 GHz up to 22 GHz, depending on the current density. The oscillation frequency does not depend on the guide magnetic field magnitude. A maximal output power of 15[plus minus]5 MW in asymmetric transverse magnetic (TM) modes is achieved by the axially extracted vircator. Variation of the magnetic field intensity in a range of 0--40 kG has an insignificant effect upon the emitted microwave power. An electron beam power to microwave power conversion efficiency of approximately 1% is obtained.

  8. Microwave generation from an axially extracted virtual cathode oscillator with a guide magnetic field

    International Nuclear Information System (INIS)

    The operation of a virtual cathode oscillator (vircator) with strong axial magnetic field has been experimentally studied. Depending on the cathode--anode gap and cathode diameter, the operating voltage varies from 200 kV up to 480 kV with 2--7 kA diode current. Microwave emission is produced by the oscillating virtual cathode. The central microwave frequency follows the beam plasma frequency. It varies by 11.5 GHz up to 22 GHz, depending on the current density. The oscillation frequency does not depend on the guide magnetic field magnitude. A maximal output power of 15±5 MW in asymmetric transverse magnetic (TM) modes is achieved by the axially extracted vircator. Variation of the magnetic field intensity in a range of 0--40 kG has an insignificant effect upon the emitted microwave power. An electron beam power to microwave power conversion efficiency of approximately 1% is obtained

  9. Effect of axial magnetic field on axicon laser-induced electron acceleration

    Science.gov (United States)

    Kant, Niti; Rajput, Jyoti; Giri, Pankaj; Singh, Arvinder

    2016-03-01

    Radially polarized axicon Gaussian laser-induced electron acceleration has been studied under the influence of axial magnetic field. Employing an axicon is a significant method to generate a focused and diffraction free radially polarized laser beam. We have investigated direct electron acceleration in vacuum by employing a relativistic single particle simulation. It is observed that the net electron energy gain from the axicon Gaussian radially polarized laser beam can be enhanced under the influence of time varying axial magnetic field. This additional effect of the magnetic field reveals the fact that multi GeV energy gain can be achieved without the use of petawatt power lasers. Effect of laser initial intensity, initial spot size, initial phase, pulse duration and initial energy are taken into consideration for efficient electron acceleration up to GeV energies.

  10. Experimental investigation of axial plasma injection into a magnetic dipole field

    DEFF Research Database (Denmark)

    Jensen, Vagn Orla

    1968-01-01

    A high-density helium plasma, accelerated from a conical pinch, is injected axially into a magnetic dipole field. Magnetic probe measurements show that, near the axis, a compression of the field is super-imposed on the standard diamagnetic depression. The compression starts downstream and moves...... towards the injector. Simultaneously with the compression, an increase in the electron temperature and reflection of a small amount of plasma are seen. The amount of plasma transmitted through the dipole field is found to be nearly independent of the field strength....

  11. Influence of axial self-magnetic field component on arcing behavior of spiral-shaped contacts

    International Nuclear Information System (INIS)

    The transverse magnetic field (TMF) contact design is commonly used in vacuum interrupters. When arcing occurs between the TMF contacts, the contact structure can create a self-induced magnetic field that drives the arc to move and rotate on the contact, and thus local overheating and severe erosion can be avoided. However, TMF contacts could also create an axial self-magnetic component, and the influence of this component on the arc behavior has not been considered to date. In this paper, five different types of Cu-Cr spiral-shaped TMF contacts with three different structures are investigated in a demountable vacuum chamber that contains a high-speed charge-coupled device video camera. It was found that the contact structure greatly influenced the arc behavior, especially in terms of arc rotation and the effective contact area, while contacts with the same slot structure but different diameters showed similar arc behavior and arc motion. The magnetic field distribution and the Lorentz force of each of the three different contact structures are simulated, and the axial self-magnetic field was first taken into consideration for investigation of the TMF contact design. It was found that contact designs that have higher axial self-magnetic field components tend to have arc columns with larger diameters and show poorer arc motion and rotation performance in the experiments

  12. Influence of axial self-magnetic field component on arcing behavior of spiral-shaped contacts

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Dingyu; Xiu, Shixin, E-mail: xsx@mail.xjtu.edu.cn; Wang, Yi; Liu, Gang [State Key Laboratory of Electrical Insulation and Power Equipment, Xi' an Jiaotong University, Xi' an 710049 (China); Zhang, Yali; Bi, Dongli [Shaanxi Baoguang Vacuum Electric Device Co., Ltd., 53 Xibao Road, Baoji 721006 (China)

    2015-10-15

    The transverse magnetic field (TMF) contact design is commonly used in vacuum interrupters. When arcing occurs between the TMF contacts, the contact structure can create a self-induced magnetic field that drives the arc to move and rotate on the contact, and thus local overheating and severe erosion can be avoided. However, TMF contacts could also create an axial self-magnetic component, and the influence of this component on the arc behavior has not been considered to date. In this paper, five different types of Cu-Cr spiral-shaped TMF contacts with three different structures are investigated in a demountable vacuum chamber that contains a high-speed charge-coupled device video camera. It was found that the contact structure greatly influenced the arc behavior, especially in terms of arc rotation and the effective contact area, while contacts with the same slot structure but different diameters showed similar arc behavior and arc motion. The magnetic field distribution and the Lorentz force of each of the three different contact structures are simulated, and the axial self-magnetic field was first taken into consideration for investigation of the TMF contact design. It was found that contact designs that have higher axial self-magnetic field components tend to have arc columns with larger diameters and show poorer arc motion and rotation performance in the experiments.

  13. Axial electric wake field inside the induction gap exited by the intense electron beam

    Institute of Scientific and Technical Information of China (English)

    ZHANG Kai-Zhi; ZHANG Huang; LONG Ji-Dong; YANG Guo-Jun; HE Xiao-Zhong; WANG Hua-Cen

    2008-01-01

    While an intense electron beam passes through the accelerating gaps of a linear induction accelerator,a strong wake field will be excited.In this paper a relatively simple model is established based on the interaction between the transverse magnetic wake field and the electron beam,and the numerical calculation in succession generates a magnetic wake field distribution along the accelerator and along the beam pulse as well.The axial electric wake field is derived based on the relation between field components of a resonant mode.According to some principles in existence,the influence of this field on the high voltage properties of the induction gap is analyzed.The Dragon-I accelerator is taken as an example,and its maximum electric wake field is about 17 kV/cm,which means the effect of the wake field is noticeable.

  14. On a possibility for determination of the field integral in muon magnetic spectrometers

    International Nuclear Information System (INIS)

    An analysis of capabilities of the available methods for determination of the field integral in muon magnetic spectrometers is made. Some difficulties connected with the use of these methods under the conditions of the ANI magnetic spectrometer are shown. A computerized simulation technique for determination of the field integral based on the use of a vertical flux of cosmic muons is proposed and substantiated. On the example of the ANI spectrometer numerical data are obtained which allow to choose optical parameters of measuring complex for the field integral determination. 14 refs.; 6 figs.; 9 tabs

  15. Analysis of the axial electric field in a plasma-loaded-helix travelling wave tube

    Institute of Scientific and Technical Information of China (English)

    Xie Hong-Quan; Liu Pu-Kun

    2006-01-01

    A helix type slow wave structure filled with plasma is immersed in a strong longitudinal magnetic field. Taking into account the effect of the plasma and the dielectric, the system is separated radially into three regions. By means of the sheath model and Maxwell equation, the distribution of the electromagnetic field is established. Using the boundary conditions of each region, the dispersion relation of the slow wave structure is derived. The trend of change for the radial profile of the axial electric field is analysed respectively in different plasma densities, plasma column radius and dielectric constant by numerical computation. Some useful results are obtained on the basis of the discussion.

  16. Chiral extrapolation of nucleon axial charge $g_A$ in effective field theory

    CERN Document Server

    Li, Hongna

    2016-01-01

    The extrapolation of nucleon axial charge $g_A$ is investigated within the framework of heavy baryon chiral effective field theory. The intermediate octet and decuplet baryons are included in the one loop calculation. Finite range regularization is applied to improve the convergence in the quark-mass expansion. The lattice data from three different groups are used for the extrapolation. At physical pion mass, the extrapolated $g_A$ are all smaller than the experimental value.

  17. Portable Remote Imaging Spectrometer (PRISM): Laboratory and Field Calibration

    Science.gov (United States)

    Mouroulis, Pantazis; Van Gorp, Byron; Green, Robert O.; Eastwood, Michael; Boardman, Joseph; Richardson, Brandon S.; Rodriguez, Jose I.; Urquiza, Eugenio; Franklin, Brian D.; Gao, Bo-Cai

    2012-01-01

    We report the characteristics of the Portable Remote Imaging Spectrometer, an airborne sensor specifically designed for the challenges of coastal ocean research. PRISM has high signal to noise ratio and uniformity, as well as low polarization sensitivity. Acquisition of high quality data has been demonstrated with the first engineering flight.

  18. Numerical study of arc plasmas and weld pools for GTAW with applied axial magnetic fields

    International Nuclear Information System (INIS)

    A 3D numerical model containing the welding arc and the weld pool for gas tungsten arc welding (GTAW) with applied axial magnetic fields is established. The model is validated by comparing the calculated arc temperature with the measured ones. The influence of the magnetic field on the welding process is studied by changing the magnetic inductions, from 0 T to 0.06 T. For welding arcs, a radial spread is discovered, and a reverse flow appears over the anode. The distribution of temperature, heat flux, current density and pressure on the anode surface becomes double-peaked, while the voltage distributes in a double-valley type. For weld pools, the fluid flow cycle brings about a wide and shallow pool. In the circumferential direction, the fluid in the centre areas rotates in an opposite direction to that in the outer regions; in the axial direction, the fluid flows upwards at the centre while downwards in the edge area of the weld pool. All the driving forces including the surface tension, the shear stress from the arc plasma, the electromagnetic force and the buoyancy force that influence the fluid flow are analysed to explain these phenomena. The mechanism of how the applied axial magnetic field regulates the GTAW process is thus clarified. (paper)

  19. High Pressure XENON Gamma-Ray Spectrometers for Field Use

    International Nuclear Information System (INIS)

    This project explored a new concept for high-pressure xenon ionization chambers by replacing the Frisch grid with coplanar grid electrodes similar to those used in wide bandgap semiconductor gamma-ray spectrometers. This work is the first attempt to apply the coplanar grid anode design in a gas ionization chamber in order to achieve to improved energy resolution. Three prototype detectors, two cylindrical and one parallel plate configurations, were built and tested. While the detectors did not demonstrate energy resolutions as good as other high pressure xenon gamma-ray spectrometers, the results demonstrated that the concept of single polarity charge sending using coplanar grid electrodes will work in a gas detector

  20. Ray tracing method for the grazing incidence flat-field imaging soft X-ray spectrometer

    International Nuclear Information System (INIS)

    A ray tracing method is introduced for helping adjustment and spectra analysis of the grazing incidence flat-field imaging soft X-ray spectrometer. For a single point source, the spectra images obtained by separate components, the toroidal mirror, and the grazing incidence flat-field concave grating with varied line spaces are given respectively. The calculated spectral images of the single point source by the spectrometer are also given for comparison with measurements with different experimental alignments

  1. Plasma flow crisis and limiting electron temperature in a vacuum arc and in axial magnetic field

    International Nuclear Information System (INIS)

    One studied possibility of supersonic motion of cathode plasma in a weak-current vacuum arc placed in axial magnetic field. Increase of electron temperature is shown to result inevitably in reduction of plasma speed up to sonic speed, that is, flow crisis. One derived dependence of the boundary length of plasma stationary flow on magnetic field. The maximum attainable electron temperature of plasma was determined to be governed by ion initial energy and to be equal to the triple value of electron temperature within cathode spot range

  2. Axial anomaly of QED in a strong magnetic field and noncommutative anomaly

    OpenAIRE

    Sadooghi, N.; Salim, A. Jafari

    2006-01-01

    The Adler-Bell-Jackiw (ABJ) anomaly of a 3+1 dimensional QED is calculated in the presence of a strong magnetic field. It is shown that in the regime with the lowest Landau level (LLL) dominance a dimensional reduction from D=4 to D=2 dimensions occurs in the longitudinal sector of the low energy effective field theory. In the chiral limit, the resulting anomaly is therefore comparable with the axial anomaly of a two dimensional massless Schwinger model. It is further shown that the U(1) axia...

  3. One half of the central detector for the Axial Field Spectrometer (AFS)experiment R807

    CERN Multimedia

    1979-01-01

    This experiment was setup at the ISR intersection I-8 by the Brookhaven-CERN-Copenhagen-Lund-Rutherford Lab.-Tel Aviv Collaboration to study large transverse momentum phenomena (see Annual Report 1979 p. 69). The central detector (here shown for a part) was a cylindrical drift chamber with fine azimuthal segmentation.

  4. Effect of axial magnetic field on a 2.45 GHz permanent magnet ECR ion source

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, T., E-mail: tsubasa@oshima-k.ac.jp; Wada, H.; Furuse, M. [National Institute of Technology, Oshima College, 1091-1 Komatsu, Suouoshima, Oshima, Yamaguchi 742-2193 (Japan); Asaji, T. [National Institute of Technology, Toyama College, 13 Hongo, Toyama 939-8630 (Japan)

    2016-02-15

    Herein, we conduct a fundamental study to improve the generation efficiency of a multi-charged ion source using argon. A magnetic field of our electron cyclotron resonance ion source is composed of a permanent magnet and a solenoid coil. Thereby, the axial magnetic field in the chamber can be tuned. Using the solenoid coil, we varied the magnetic field strength in the plasma chamber and measured the ion beam current extracted at the electrode. We observed an approximately three times increase in the Ar{sup 4+} ion beam current when the magnetic field on the extractor-electrode side of the chamber was weakened. From our results, we can confirm that the multi-charged ion beam current changes depending on magnetic field intensity in the plasma chamber.

  5. Investigation of the space charge axial oscillations in the cross fields

    International Nuclear Information System (INIS)

    The space charge oscillations are prominent in the performance of the cross fields devices Two main types of oscillations are known: radially-symmetrical oscillations (RSO) and running wave oscillations (RWO). Alongside with the RSO and RWO the space charge oscillations along the magnetic field B are possible in the cross field systems. The possibility of axial electron movement is indicated by some authors. The exis- tance of the space charge cooperative oscillations along the magnetic field (axial oscillations-AO) in M-type amplifier has shown from analysis of the end current high-frequency modulation. In order to find out AO regularities the further investigations in the various systems with the cross fields are necessary. In the present work AO were studied in the magnetron diode (MD) with the smooth anode (20mm in diameter) and cold CuBeAl alloy cathode (13mm in diameter). The pressure in the diode changed from 10-6 to 10-4 Torr. MD starting was accomplished with auxiliary starting thermo-cathode located not far from the end of the basic cathode. (Auth.)

  6. Development results of portable gamma-radiation HPGe spectrometer with electric cooling for field applications

    International Nuclear Information System (INIS)

    The paper presents development results of a portable spectrometer based on high purity germanium (HPGe spectrometer) with Stirling electric cooler for field applications. The spectrometer cryostat allows installation of HPGe coaxial detectors with efficiency up to 40% and planar detectors with sensitive area up to 3000 mm2. The detector cooling time is not more than 8 hours. Despite the mechanical vibrations due to electric cooler operation, the obtained energy resolution of the spectrometer with coaxial detector of 10% efficiency was less than 1,0 and 2,0 keV by energies 122 and 1332 keV accordingly. Miniature processor device (Android) allows control for all operation modes of the spectrometer, provides self diagnostics, initial procession, indication and spectra accumulation

  7. Magnetic Field Calculations for the Technical Proposal of the TESLA Spectrometer Magnet

    CERN Document Server

    Morozov, N A

    2003-01-01

    The TESLA electron-positron linear collider is under consideration at DESY (Hamburg). The realization of the physical program at this collider requires the knowledge of the beam energy of both beams (e^{+} and e^{-}) with a precision of \\Delta E/E \\leq 10^{-4}. The magnetic spectrometer was proposed as an energy measuring device. The report describes calculations for the preliminary conceptual design of this type of spectrometer. The 2D calculations of the magnetic field for the spectrometer magnet have been performed by POISSON SUPERFISH computer code. The basic technical parameters of the magnet have been determined. These data will serve as a basis for the technical design of the spectrometer magnet and discuss its integration in the spectrometer.

  8. Axial behaviors of a theta pinch plasma with an antiparallel trapped magnetic field

    International Nuclear Information System (INIS)

    Fundamental plasma behavior has been almost revealed for theta pinch method in the researches for realizing controlled fusion reactions. Interest is also being taken in the axial behavior of plasma under such condition that the direction of the line of magnetic force confined in a pinched plasma column is reversed in relation to external magnetic field. The authors examined the axial behavior of linear theta pinch plasma with a high speed camera using the image converter tube RCA-4449A and the magnetic probe, and succeeded in photographing the details of plasma shape and its change with time. The experimental results and examinations are described in detail with the outline of experimental apparatuses, and summarized as follows. Area waves in compressional wave mode were observed during a second half cycle of discharge current, and the measured value of their propagation speed coincided with the calculated value. Collision of area waves at the center of the coil did not give the effect to annihilate the antiparallel field. Antiparalllel field arrangement, in which the location of zero magnetic field exists in pinch plasma, presents interesting problems such as heating and the stability in torus system in addition to the phenomena of area waves. The study with toroidal pinch will be a future research subject. (Wakatsuki, Y.)

  9. In-Field Absolute Calibration of Ground and Airborne VIS-NIR-SWIR Hyperspectral Point Spectrometers

    Directory of Open Access Journals (Sweden)

    Offer Rozenstein

    2014-01-01

    Full Text Available Spectrometer calibration and measurements of spectral radiance are often required when performing ground, aerial, and space measurements. While calibrating a spectrometer in the field using an integrating sphere is practically unachievable, calibration against a quartz halogen (QH lamp is a quite easy and feasible option. We describe a calibration protocol whereby a professional QH lamp, operating with a stabilized current source, is first calibrated in the laboratory against a US National Institute of Standards and Technology (NIST traceable integrating sphere and, then, used for the field calibration of a spectrometer before a ground or airborne campaign. Another advantage of the lamp over the integrating sphere is its ability to create a continuous calibration curve at the spectrometer resolution, while the integrating sphere is calibrated only for a few discrete wavelengths. A calibrated lamp could also be used for a secondary continuous calibration of an un-calibrated integrating sphere.

  10. Frame dragging, vorticity and electromagnetic fields in axially symmetric stationary spacetimes

    Energy Technology Data Exchange (ETDEWEB)

    Herrera, L [Escuela de Fisica, Universidad Central de Venezuela, Caracas, Venezuela (Venezuela); Gonzalez, G A [Escuela de Fisica, Universidad Industrial de Santander, AA 678, Bucaramanga (Colombia); Pachon, L A [Escuela de Fisica, Universidad Industrial de Santander, AA 678, Bucaramanga (Colombia); Laboratorio de AstronomIa y Fisica Teorica (LAFT), Departamento de Fisica, Facultad de Ciencias, La Universidad del Zulia, Maracaibo, 4004 (Venezuela); Rueda, J A [Escuela de Fisica, Universidad Industrial de Santander, AA 678, Bucaramanga (Colombia)

    2006-04-07

    We present a general study about the relation between the vorticity tensor and the Poynting vector of the electromagnetic field for axially symmetric stationary electrovacuum metrics. The obtained expressions allow us to understand the role of the Poynting vector in the dragging of inertial frames. The particular case of the rotating massive charged magnetic dipole is analysed in detail. In addition, the electric and magnetic parts of the Weyl tensor are calculated and the link between the latter and the vorticity is established. Then we show that, in the vacuum case, the necessary and sufficient condition for the vanishing of the magnetic part is that the spacetime be static.

  11. Growth rate enhancement of free-electron laser by two consecutive wigglers with axial magnetic field

    Indian Academy of Sciences (India)

    A Hasanbeigi; A Farhadian; E Khademi Bidhendi

    2014-06-01

    The operative mechanism for a free-electron laser (FEL) with two consecutive helical wigglers having opposite circular polarization in the presence of an axial magnetic field is proposed and analysed. With the help of fluid theory, a tenth-degree polynomial dispersion equation for electromagnetic and space-charge waves is derived. The results are used to illustrate and discuss the dependence of growth rate on different system parameters. Finally, it is shown that for the same system parameters the growth rate of the proposed structure is more than the growth rate of instability in a conventional FEL.

  12. Distribution of Cathode Spots in Vacuum Arc Under Nonuniform Axial Magnetic Fields

    Institute of Scientific and Technical Information of China (English)

    SHI Zong-qian; JIA Shen-li; WANG Li-jun; LI Xing-wen; WANG Zheng

    2007-01-01

    Recent results on the distribution of vacuum arc cathode spots (CSs) in nonuniform axial magnetic field (AMF) are presented.Based on previous studies,we deem that two contrary influences of AMF,inward effect and outward effect,are attributed to CSs distribution.With this notion,we have analyzed the controlling effectiveness of nonuniform AMF on CSs distribution. Experiments were conducted in a detachable vacuum chamber with iron-style AMF electrodes.Images of vacuum arc column and the distribution of CSs were photographed with a high-speed charge coupled device (CCD) camera. Experimental results agreed well with the theoretical analysis.

  13. Simulation Research of Magnetic Constriction Effect and Controlling by Axial Magnetic Field of Vacuum Arc

    Institute of Scientific and Technical Information of China (English)

    王立军; 贾申利; 史宗谦; 荣命哲

    2005-01-01

    Based on magnetohydrodynamic (MHD) model of vacuum arc, the computer simulation of vacuum arc was carried out in this paper. In the MHD model, mass conservation equation,momentum conservation equations, energy conservation equations, generalized ohm's law and Maxwell equation were considered. MHD equations were calculated by numerical method, and the distribution of vacuum arc plasma parameters and current density were obtained. Simulation results showed that the magnetic constriction effect of vacuum arc is primarily caused by the Hall effect. In addition, the inhibition of axial magnetic field (AMF) on constriction of vacuum arc was calculated and analyzed.

  14. Evaporative capillary instability for flow in porous media under the influence of axial electric field

    International Nuclear Information System (INIS)

    We study the linear analysis of electrohydrodynamic capillary instability of the interface between two viscous, incompressible and electrically conducting fluids in a fully saturated porous medium, when the phases are enclosed between two horizontal cylindrical surfaces coaxial with the interface and, when there is mass and heat transfer across the interface. The fluids are subjected to a constant electric field in the axial direction. Here, we use an irrotational theory in which the motion and pressure are irrotational and the viscosity enters through the jump in the viscous normal stress in the normal stress balance at the interface. A quadratic dispersion relation that accounts for the growth of axisymmetric waves is obtained and stability criterion is given in terms of a critical value of wave number as well as electric field. It is observed that heat transfer has stabilizing effect on the stability of the considered system while medium porosity destabilizes the interface. The axial electric field has dual effect on the stability analysis

  15. Electron injection for direct acceleration to multi-GeV energy by a Gaussian laser field under the influence of axial magnetic field

    Science.gov (United States)

    Ghotra, Harjit Singh; Kant, Niti

    2016-05-01

    Electron injected in the path of a circularly polarized Gaussian laser beam under the influence of an external axial magnetic field is shown to be accelerated with a several GeV of energy in vacuum. A small angle of injection δ with 0 ∘ propagation of laser pulse is suggested for better trapping of electron in laser field and stronger betatron resonance under the influence of axial magnetic field. Such an optimized electron injection with axial magnetic field maximizes the acceleration gradient and electron energy gain with low electron scattering.

  16. Electron injection for direct acceleration to multi-GeV energy by a Gaussian laser field under the influence of axial magnetic field

    Science.gov (United States)

    Ghotra, Harjit Singh; Kant, Niti

    2016-05-01

    Electron injected in the path of a circularly polarized Gaussian laser beam under the influence of an external axial magnetic field is shown to be accelerated with a several GeV of energy in vacuum. A small angle of injection δ with 0 ∘ < δ < 20 ∘ for a sideway injection of electron about the axis of propagation of laser pulse is suggested for better trapping of electron in laser field and stronger betatron resonance under the influence of axial magnetic field. Such an optimized electron injection with axial magnetic field maximizes the acceleration gradient and electron energy gain with low electron scattering.

  17. Magnetohydrodynamic stability of cylindrical liquid bridges under a uniform axial magnetic field

    Science.gov (United States)

    Nicolás, J. A.

    1992-11-01

    The effect of a uniform axial magnetic field on the stability of cylindrical liquid bridges of negligible viscosity and resistivity is examined in this paper, in the limit case when magnetic forces dominate inertia forces. The analysis yields the bifurcation curve and the growth factor in the neighborhood of the stability limit points as a function of two dimensionless parameters: Λ, the slenderness of the bridge and M, a nondimensional quantity proportional to the magnetic field. It is found that bridges of any slenderness can be stabilized by magnetic fields when M≳1/√2. The results are compared to those existing for capillary liquid jets, showing that the stability curves coincide and that the stabilizing effects are greater for liquid bridges than for infinite columns.

  18. Theory and experimental show up of axial magnetic fields self-generated in dense laser-produced plasmas

    International Nuclear Information System (INIS)

    The work presented in this thesis concerns the magnetic fields generated in laser produced plasma. A summary of the theoretical and experimental studies concerning the toroidal magnetic fields and realised by different groups of research is presented. Then, we present our original contribution on the generation of axial magnetic fields by the dynamo effect. The experimental work for the detection of magnetic field is based on the Faraday rotation and Zeeman effects. The experimental diagrams are detailed and discussed. The experimental results are presented and compared to the theory. Finaly, we present some consequences of the generation of the axial magnetic fields in laser produced plasma as a discussion of the thermal conductivity

  19. Personnel neutron dose assessment upgrade: Volume 2, Field neutron spectrometer for health physics applications

    International Nuclear Information System (INIS)

    Both the (ICRP) and the (NCPR) have recommended an increase in neutron quality factors and the adoption of effective dose equivalent methods. The series of reports entitled Personnel Neutron Dose Assessment Upgrade (PNL-6620) addresses these changes. Volume 1 in this series of reports (Personnel Neutron Dosimetry Assessment) provided guidance on the characteristics, use, and calibration of personnel neutron dosimeters in order to meet the new recommendations. This report, Volume 2: Field Neutron Spectrometer for Health Physics Applications describes the development of a portable field spectrometer which can be set up for use in a few minutes by a single person. The field spectrometer described herein represents a significant advance in improving the accuracy of neutron dose assessment. It permits an immediate analysis of the energy spectral distribution associated with the radiation from which neutron quality factor can be determined. It is now possible to depart from the use of maximum Q by determining and realistically applying a lower Q based on spectral data. The field spectrometer is made up of two modules: a detector module with built-in electronics and an analysis module with a IBM PC/reg sign/-compatible computer to control the data acquisition and analysis of data in the field. The unit is simple enough to allow the operator to perform spectral measurements with minimal training. The instrument is intended for use in steady-state radiation fields with neutrons energies covering the fission spectrum range. The prototype field spectrometer has been field tested in plutonium processing facilities, and has been proven to operate satisfactorily. The prototype field spectrometer uses a 3He proportional counter to measure the neutron energy spectrum between 50 keV and 5 MeV and a tissue equivalent proportional counter (TEPC) to measure absorbed neutron dose

  20. Converging Cylindrical Shock Waves in a Nonideal Gas With an Axial Magnetic Field

    Directory of Open Access Journals (Sweden)

    J. P. Vishwakarma

    2006-11-01

    Full Text Available This paper analyses the propagation of converging cylindrical shock waves in a nonidealgas, in the presence of an axial magnetic field. Chester-Chisnell-Whitham’s method has beenemployed to determine the shock velocity and the other flow-variables just behind the shockin the cases, when (i the gas is weakly ionised before and behind the shock front, (ii the gasis strongly ionised before and behind the shock front, and (iii nonionised gas undergoes intenseionisation as a result of the passage of the shock. The effects of the nonidealness of the gas,the conductivity of the gas, and the axial magnetic field have been investigated. It is found thatin the case (i, an increase in the value of parameter ( characterising the nonidealness of thegas accelerates the convergence of the shock. In the case (ii, the shock speed and pressurebehind the shock increase very fast as the axis is approached; and this increase occurs earlierif the strength of the initial magnetic field is increased. In the case (iii, for smaller values of theinitial magnetic field, the shock speed, and pressure behind the shock decrease very fast afterattaining a maximum; and for higher values of the initial magnetic field, the tendency of decreaseappears from the beginning. This shows that the magnetic field has damping effect on the shockpropagation. In the case (iii, it was also found that the growth of the shock in the initial phaseand decay in the last phase were faster when it was converging in a nonideal gas in comparisonwith that in a perfect gas. Further, it has been shown that the gas-ionising nature of the shockhas damping effect on its convergence.

  1. High-rate axial-field ionization chamber for particle identification of radioactive beams

    CERN Document Server

    Vadas, J; Visser, G; Alexander, A; Hudan, S; Huston, J; Wiggins, B B; Chbihi, A; Famiano, M; Bischak, M M; deSouza, R T

    2016-01-01

    The design, construction and performance characteristics of a simple axial-field ionization chamber suitable for identifying ions in a radioactive beam are presented. Optimized for use with low-energy radioactive beams (< 5 MeV/A) the detector presents only three 0.5 $\\mu$m/cm$^2$ foils to the beam in addition to the detector gas. A fast charge sensitive amplifier (CSA) integrated into the detector design is also described. Coupling this fast CSA to the axial field ionization chamber produces an output pulse with a risetime of 60-70 ns and a fall time of 100 ns, making the detector capable of sustaining a relatively high rate. Tests with an $\\alpha$ source establish the detector energy resolution as $\\sim$8 $\\%$ for an energy deposit of $\\sim$3.5 MeV. The energy resolution with beams of 2.5 and 4.0 MeV/A $^{39}$K ions and the dependence of the energy resolution on beam intensity is measured. At an instantaneous rate of 3 x 10$^5$ ions/s the energy resolution has degraded to 14% with a pileup of 12%. The go...

  2. The effect of residual axial gravity on the stability of liquid columns subjected to electric fields

    Science.gov (United States)

    Gonzalez, Heliodoro; Castellanos, Antonio

    1993-04-01

    The stability criterion for almost cylindrical dielectric liquid bridges subjected to axial electric fields in the presence of residual axial gravity is obtained. In its absence, a perfectly cylindrical equilibrium solution is allowed for all values of the relevant parameters, which are the slenderness of the liquid bridge, the electrical Bond number and the relative permittivity between the outer and inner media. This basic solution is unstable beyond a critical slenderness which varies with the electrical parameters (Gonzalez et al. 1989). The destabilization takes place axisymmetrically. The inclusion of the gravitational Bond number as a new, small parameter may be treated by means of the Liapunov-Schmidt Method, a well-known projection technique that gives the local bifurcation diagram relating the admissible equilibrium amplitudes for the liquid bridge and the aforementioned parameters. As in the absence of applied electric field, the gravitational Bond number breaks the pitchfork diagram into two isolated branches of axisymmetric equilibrium solutions. The stable one has a turning point whose location determines the new stability criterion. Quantitative results are presented after solving the resulting set of linear recursive problems by means of the method of lines.

  3. Numerical analysis of branched cracks in bi-axial stress fields

    International Nuclear Information System (INIS)

    The stress corrosion cracks as seen for example in PWR steam generator tubing made of Inconel 600 are usually found to be of highly irregular kinked and branched shapes. Numerical analysis of kinked and branched cracks in bi-axial plane stress fields using methods such as finite or boundary element method may provide useful and cost effective solutions. However, accurate analysis of complex shaped cracks requires very fine meshes and, consequently, excessively high computational efforts. This paper discusses some possible strategies of numerical modeling of kinked and branched cracks in general bi-axial stress field using the general-purpose finite element code ABAQUS. The strategies discussed include J-integral and stress intensity factor solutions with different mesh densities. The accuracy of the numerical results obtained is compared with reference solutions from the literature. The main result of the paper is an optimal numerical strategy, which maximizes the accuracy of the result at as low computational efforts as feasible. The selected optimal strategy is expected to be used in the future simulations of large networks of inter-granular stress corrosion cracks at the grain-size scale using incomplete random tessellation.(author)

  4. Kr II and Xe II axial velocity distribution functions in a cross-field ion source

    International Nuclear Information System (INIS)

    Laser induced fluorescence measurements were carried out in a cross-field ion source to examine the behaviour of the axial ion velocity distribution functions (VDFs) in the expanding plasma. In the present paper, we focus on the axial VDFs of Kr II and Xe II ions. We examine the contourplots in a 1D-phase space (x,vx) representation in front of the exhaust channel and along the centerline of the ion source. The main ion beam, whose momentum corresponds to the ions that are accelerated through the whole potential drop, is observed. A secondary structure reveals the ions coming from the opposite side of the channel. We show that the formation of the neutralized ion flow is governed by the annular geometry. The assumption of a collisionless shock or a double layer due to supersonic beam interaction is not necessary. A non-negligible fraction of slow ions originates in local ionization or charge-exchange collision events between ions of the expanding plasma and atoms of the background residual gas. Slow ions that are produced near the centerline in the vicinity of the exit plane are accelerated toward the source body with a negative velocity leading to a high sputtering of front face. On the contrary, the ions that are produced in the vicinity of the channel exit plane are partially accelerated by the extended electric field.

  5. Axial magnetic field extraction type microwave ion source with a permanent magnet

    International Nuclear Information System (INIS)

    A new type of microwave ion source in which a permanent magnet generates an axially directed magnetic field needed for the electron cyclotron resonance was developed. The electron cyclotron resonance produces a high density plasma in the ion source. A mA-order ion beam can be extracted. Compared with usual microwave ion sources, this source has a distinguished feature in that the axially directed magnetic field is formed by use of a permanent magnet. Shape of magnetic force lines near the ion extraction aperture was carefully investigated. The extracted ion current as a function of the ion extraction voltage was measured. The experimental data are in good agreement with the theoretical line. The ion source can be heated up to 500 deg C, and extraction of the alkaline metal ions is possible. The extracted ion current for various elements are shown in the table. The current density normalized by the proton was 350-650 mA/cm2 which was nearly equal to the upper limit of the extractable positive ion current density. The plasma density was estimated and was 2 - 3 x 1012 cm-3. The mass spectrum of a Cesium ion beam was obtained. A negligible amount of impurities was observed. The emittance diagram of the extracted ion beam was measured. The result shows that a low emittance and high brightness ion source is constructed. (Kato, T.)

  6. Field-Dependent BRS Tranformations and Correct Prescription for $1/(n.k)^{p}$-Type Singularities in Axial Gauges

    CERN Document Server

    Misra, A

    2000-01-01

    The axial-gauge boson propagator contains 1/(n.k)^p-type singularities. These singularities have generally been treated by inventing prescriptions for them. We propose an alternative procedere for treating these singularities in the path-integral formalism using the known way of treating the 1/k^{2n}-type singularities in Lorentz-type gauges. For this purpose we use a finite field-dependent BRS transformation that inerpolates between the Lorentz and axial-type gauges. We arrive at the \\epsilon-dependent tree propagator in axial-type gauges.

  7. Modifications of the Fourier approach for magnetic field calculations to include axial shields in superconducting magnets

    International Nuclear Information System (INIS)

    Martinelli and Morini have used an analytical method for calculating values and distribution of the magnetic field in superconducting magnets. Using Fourier series the magnetic field is determined by carrying out a series expansion of the current density distribution of the system of coils. This Fourier method can be modified to include axial iron to a far greater accuracy (for finite permeability) by incorporating the image series approach of Caldwell and Zisserman. Also an exact solution can be obtained for the case of infinite permeability. A comparison of the results derived from the expansion of Martinelli and Morini with the exact solution of Caldwell and Zisserman shows excellent agreement for the iron-free case but the accuracy deteriorates as the permeability μ/sub z/ increases. The exact solution should be used for infinite permeability and also gives satisfactory results for permeability μ/sub z/ >100. A symmetric geometry is used throughout the communication for simplicity of presentation

  8. Near-Field Characterization of Radial and Axial Blast Waves From a Cylindrical Explosive Charge

    Science.gov (United States)

    McNesby, Kevin; Homan, Barrie

    This paper uses experiment (high speed imaging) and simulation (ALE-3D) to investigate radial and axial blast waves produced by uncased, cylindrical charges of TNT (trinitrotoluene). Recently there has been work reported on predicting secondary blast waves in the explosive mid-field (approximately 1 meter from charge center of mass) for cylindrical charges of RDX (trimethylenetrinitramine)/binder formulations. The work we will present seeks to provide complementary information in the explosive near-field, including the approach to chemical ``freeze out'', for end-detonated, right circular cylinders of TNT. Additionally, this work attempts to retrieve state variables (temperature, pressure, velocities) from high-definition images of the explosive event. Keywords: cylindrical charges, blast, shock waves

  9. Analyzing Axial Stress and Deformation of Tubular for Steam Injection Process in Deviated Wells Based on the Varied Fields

    OpenAIRE

    Yunqiang Liu; Jiuping Xu; Shize Wang; Bin Qi

    2013-01-01

    The axial stress and deformation of high temperature high pressure deviated gas wells are studied. A new model is multiple nonlinear equation systems by comprehensive consideration of axial load of tubular string, internal and external fluid pressure, normal pressure between the tubular and well wall, and friction and viscous friction of fluid flowing. The varied temperature and pressure fields were researched by the coupled differential equations concerning mass, momentum, and energy equatio...

  10. Intensity-modulated radiation therapy: overlapping co-axial modulated fields

    Energy Technology Data Exchange (ETDEWEB)

    Metcalfe, P [Centre for Medical Radiation Physics, University of Wollongong, NSW (Australia); Tangboonduangjit, P [Centre for Medical Radiation Physics, University of Wollongong, NSW (Australia); White, P [Nepean Cancer Care Centre, Sydney, NSW (Australia)

    2004-08-21

    The Varian multi-leaf collimator has a 14.5 cm leaf extension limit from each carriage. This means the target volumes in the head and neck region are sometimes too wide for standard width-modulated fields to provide adequate dose coverage. A solution is to set up asymmetric co-axial overlapping fields. This protects the MLC carriage while in return the MLC provides modulated dose blending in the field overlap region. Planar dose maps for coincident fields from the Pinnacle radiotherapy treatment planning system are compared with planar dose maps reconstructed from radiographic film and electronic portal images. The film and portal images show small leaf-jaw matchlines at each field overlap border. Linear profiles taken across each image show that the observed leaf-jaw matchlines from the accelerator images are not accounted for by the treatment planning system. Dose difference between film reconstructed electronic portal images and planning system are about 2.5 cGy in a modulated field at d{sub max}. While the magnitude of the dose differences are small improved round end leaf modelling combined with a finer dose calculation grid may minimize the discrepancy between calculated and delivered dose.

  11. Effect of an Electric Field on Transfer Processes in Axially Symmetric Magnetic Traps

    International Nuclear Information System (INIS)

    By solving the kinetic equation in the drift approximation, expressions are derived for the particle flux and energy density across a strong magnetic field in axially symmetric systems of the Levitron or Tokamak type. In addition to the longitudinal accelerating electric field, which is responsible for creating the longitudinal current, account is taken of the presence of a quasistatic electric field directed along the minor radius and resulting from ambipolarity of dispersion. Both the case of very low collision frequencies (lower than the characteristic frequency of the azimuthal motion of the ''blocked'' particles) and that of intermediate and high collision frequencies are considered. It is shown that, if either the thermal velocity of the particles or the ratio of the poloidal magnetic field to the longitudinal magnetic field is fairly large (so that the mean longitudinal velocity of the toroidally ''blocked'' particles is much less than the azimuthal variations of their longitudinal velocity), then allowance for the radial electric field corresponds to allowance in the flux expressions for corrections of the next higher (i.e. fourth) order with respect to the smallness parameter used. In the opposite limiting case, allowance for the radial electric field becomes very important: in the region of very low and very high collision frequencies it leads to a substantial change in the functional dependence of the dispersion and heat conduction coefficients on the plasma and magnetic field parameters, while in the region of intermediate collision frequencies it leads to corrections proportional to the square of the ratio of the Larmor radius in the poloidal magnetic field to the characteristic dimension of the plasma inhomogeneity. In conclusion, the author discusses the question of determining a self-consistent radial electric field within the framework of a theory which takes into account only the lowest order with respect to the Larmor radius. (author)

  12. Ultra-Compact Imaging Spectrometer (UCIS) for In-Situ Planetary Mineralogy: Laboratory and Field Calibration

    Science.gov (United States)

    Van Gorp, Byron; Mouroulis, Pantazis; Green, Robert O.; Rodriguez, Jose I.; Blaney, Diana; Wilson, Daniel W.; Sellar, R. Glenn; Richardson, Brandon S.

    2012-01-01

    The Ultra-Compact Imaging Spectrometer (UCIS) is a miniature telescope and spectrometer system intended for mapping terrain mineralogy over distances from 1.5 m to infinity with spatial sampling of 1.35 mrad over a 33 deg field, and spectral sampling of 10 nm in the 600-2500 nm range. The core of the system has been designed for operation in a Martian environment, but can also be used in a terrestrial environment when placed inside a vacuum vessel. We report the laboratory and field calibration data that include spatial and spectral calibration, and demonstrate the use of the system.

  13. Research on an Axial Magnetic-Field-Modulated Brushless Double Rotor Machine

    Directory of Open Access Journals (Sweden)

    Bin Yu

    2013-09-01

    Full Text Available Double rotor machine, an electronic continuously variable transmission, has great potential in application of hybrid electric vehicles (HEVs, wind power and marine propulsion. In this paper, an axial magnetic-field-modulated brushless double rotor machine (MFM-BDRM, which can realize the speed decoupling between the shaft of the modulating ring rotor and that of the permanent magnet rotor is proposed. Without brushes and slip rings, the axial MFM-BDRM offers significant advantages such as excellent reliability and high efficiency. Since the number of pole pairs of the stator is not equal to that of the permanent magnet rotor, which differs from the traditional permanent magnet synchronous machine, the operating principle of the MFM-BDRM is deduced. The relations of corresponding speed and toque transmission are analytically discussed. The cogging toque characteristics, especially the order of the cogging torque are mathematically formulated. Matching principle of the number of pole pairs of the stator, that of the permanent magnet rotor and the number of ferromagnetic pole pieces is inferred since it affects MFM-BDRM’s performance greatly, especially in the respect of the cogging torque and electromagnetic torque ripple. The above analyses are assessed with the three-dimensional (3D finite-element method (FEM.

  14. Experimental Investigation of the Flow Field in a Multistage Axial Flow Compressor

    Directory of Open Access Journals (Sweden)

    B. Lakshminarayana

    1996-01-01

    Full Text Available The nature of the flow field in a three stage axial flow compressor, including a detailed survey at the exit of an embedded stator as well as the overall performance of the compressor is presented and interpreted in this paper. The measurements include area traverse of a miniature five hole probe (1.07 mm dia downstream of stator 2, radial traverses of a miniature five hole probe at the inlet, downstream of stator 3 and at the exit of the compressor at various circumferential locations, area traverse of a low response thermocouple probe downstream of stator 2, radial traverses of a single sensor hot-wire probe at the inlet, and casing static pressure measurements at various circumferential and axial locations across the compressor at the peak efficiency operating point. Mean velocity, pressure and total temperature contours as well as secondary flow contours at the exit of the stator 2 are reported and interpreted. Secondary flow contours show the migration of fluid particles toward the core of the low pressure regions located near the suction side casing endwall corner.

  15. The influence of centrifugal forces on the B field structure of an axially symmetric equilibrium magnetosphere

    International Nuclear Information System (INIS)

    The authors investigate a stationary model of a rotating, axially symmetric pole-on magnetosphere in MHD force balance. In this model both the planet's rotational and dipole axes are aligned with the magnetotail axis, which is the axis of symmetry in a cylindrical (r, φ, z) coordinate system. On the sunward side, the magnetosphere is closed by an appropriate image dipole. Inside the magnetospheric cavity they assume isotropic thermal plasma pressure. They assume further that, in general, planetary rotation leads to differentially rotating magnetotail field lines causing field-aligned Birkeland currents and a corresponding toroidal magnetic Bφ component which leads to twisted magnetotail field lines. They calculate the deformation of magnetotail field lines under the influence of both thermal plasma pressure and centrifugal forces. They present linear (analytic) solutions to the Grad-Shafranov equation which include the centrifugal force term. In the linear model, two free physical parameters, k and ω, measure the plasma thermal pressure and the ratio between plasma rotational and thermal energy densities, respectively. Low ω and high k values indicate the plasma-dominated case. Conversely, low k and high ω values indicate the rotation-dominated case. One limiting case, k = ω = 0., generates a simple vacuum magnetic field of a dipole confined within the magnetospheric cavity. The nonrotational magnetosphere with hot thermal plasma leads to a field configuration without a toroidal Bφ component and without field-aligned Birkeland currents. The other extreme, namely, a rapidly rotating magnetosphere with cold plasma, leads to a configuration in which the plasma must be confined within a thin disk in a plane where the radial magnetic field component Br vanishes locally

  16. The Axial Double Probe and Fields Signal Processing for the MMS Mission

    Science.gov (United States)

    Ergun, R. E.; Tucker, S.; Westfall, J.; Goodrich, K. A.; Malaspina, D. M.; Summers, D.; Wallace, J.; Karlsson, M.; Mack, J.; Brennan, N.; Pyke, B.; Withnell, P.; Torbert, R.; Macri, J.; Rau, D.; Dors, I.; Needell, J.; Lindqvist, P.-A.; Olsson, G.; Cully, C. M.

    2016-03-01

    The Axial Double Probe (ADP) instrument measures the DC to ˜100 kHz electric field along the spin axis of the Magnetospheric Multiscale (MMS) spacecraft (Burch et al., Space Sci. Rev., 2014, this issue), completing the vector electric field when combined with the spin plane double probes (SDP) (Torbert et al., Space Sci. Rev., 2014, this issue, Lindqvist et al., Space Sci. Rev., 2014, this issue). Two cylindrical sensors are separated by over 30 m tip-to-tip, the longest baseline on an axial DC electric field ever attempted in space. The ADP on each of the spacecraft consists of two identical, 12.67 m graphite coilable booms with second, smaller 2.25 m booms mounted on their ends. A significant effort was carried out to assure that the potential field of the MMS spacecraft acts equally on the two sensors and that photo- and secondary electron currents do not vary over the spacecraft spin. The ADP on MMS is expected to measure DC electric field with a precision of ˜1 mV/m, a resolution of ˜25 μV/m, and a range of ˜±1 V/m in most of the plasma environments MMS will encounter. The Digital Signal Processing (DSP) units on the MMS spacecraft are designed to perform analog conditioning, analog-to-digital (A/D) conversion, and digital processing on the ADP, SDP, and search coil magnetometer (SCM) (Le Contel et al., Space Sci. Rev., 2014, this issue) signals. The DSP units include digital filters, spectral processing, a high-speed burst memory, a solitary structure detector, and data compression. The DSP uses precision analog processing with, in most cases, >100 dB in dynamic range, better that -80 dB common mode rejection in electric field ( E) signal processing, and better that -80 dB cross talk between the E and SCM ( B) signals. The A/D conversion is at 16 bits with ˜1/4 LSB accuracy and ˜1 LSB noise. The digital signal processing is powerful and highly flexible allowing for maximum scientific return under a limited telemetry volume. The ADP and DSP are

  17. Polarisation Analysis Neutron Spectrometer, POLANO, at J-PARC - Concept and Magnetic Field Optimisation

    Science.gov (United States)

    Ohoyama, K.; Yokoo, T.; Itoh, S.; Nanbu, M.; Iwasa, K.; Ohkawara, M.; Kaneko, N.; Ino, T.; Hayashida, H.; Oku, T.; Kira, H.; Tasaki, S.; Takeda, M.; Kimura, H.; Sato, T. J.

    2016-04-01

    The status of the polarised neutron spectrometer constructed at the Japan Proton Accelerator Research Complex through a collaboration between Tohoku University and KEK will be reported. In particular, the optimisation of magnetic fields to minimise neutron- beam depolarisation using the finite element method will be discussed on the basis of several simulations using the finite element method.

  18. Dynamics of multiple viscoelastic carbon nanotube based nanocomposites with axial magnetic field

    International Nuclear Information System (INIS)

    Nanocomposites and magnetic field effects on nanostructures have received great attention in recent years. A large amount of research work was focused on developing the proper theoretical framework for describing many physical effects appearing in structures on nanoscale level. Great step in this direction was successful application of nonlocal continuum field theory of Eringen. In the present paper, the free transverse vibration analysis is carried out for the system composed of multiple single walled carbon nanotubes (MSWCNT) embedded in a polymer matrix and under the influence of an axial magnetic field. Equivalent nonlocal model of MSWCNT is adopted as viscoelastically coupled multi-nanobeam system (MNBS) under the influence of longitudinal magnetic field. Governing equations of motion are derived using the Newton second low and nonlocal Rayleigh beam theory, which take into account small-scale effects, the effect of nanobeam angular acceleration, internal damping and Maxwell relation. Explicit expressions for complex natural frequency are derived based on the method of separation of variables and trigonometric method for the “Clamped-Chain” system. In addition, an analytical method is proposed in order to obtain asymptotic damped natural frequency and the critical damping ratio, which are independent of boundary conditions and a number of nanobeams in MNBS. The validity of obtained results is confirmed by comparing the results obtained for complex frequencies via trigonometric method with the results obtained by using numerical methods. The influence of the longitudinal magnetic field on the free vibration response of viscoelastically coupled MNBS is discussed in detail. In addition, numerical results are presented to point out the effects of the nonlocal parameter, internal damping, and parameters of viscoelastic medium on complex natural frequencies of the system. The results demonstrate the efficiency of the suggested methodology to find the closed form

  19. Free electron laser experiment in resonant helical and axial magnetic fields

    International Nuclear Information System (INIS)

    The authors report on an intermediate energy, long pulse free electron laser (FEL). The experiment is designed to investigate cyclotron resonance effects in FELs. The power source is a Marx generator which produces a repeatable, flat accelerating voltage pulse. The thermionic electron gun operates immersed in a shaped magnetic field. The perpendicular energy of the emitted electrons is estimated to be less than one percent of their total energy. The beam propagates in a two meter long drift tube, guided by a uniform axial magnetic field that can be varied between 0.7 and 7.0 kG. The wiggler fields are generated by a bifilar helical winding. An adjustable, adiabatic entrance profile is produced by staggering the wiggler termination windings. The system has been designed to that under normal operating conditions, the emitted radiation propagates in the lowest mode of the cylindrical drift tube. The authors have observed microwave power levels of over 10 KW at approximately 10 GHz. Spectra observed with an X-band waveguide dispersive line show that most of the power is concentrated in a narrow peak (Δf/f<0.1). Preliminary results indicate that the output frequency increases with beam energy

  20. Flow Fields with Vortex in a Small Semi-open Axial Fan

    Institute of Scientific and Technical Information of China (English)

    Norimasa. Shiomi; Yoichi Kinoue; Ying zi Jin; Toshiaki Setoguchi; Kenji Kaneko

    2009-01-01

    In order to clarify the effect of tip clearance (TC) size on fan performance and the flow field at rotor outlet in a small semi-open axial fan, the experimental investigation was carried out. The tip diameter of test fan rotor was 180mm and test TC sizes were 1 mm (TC=1 mm) and 4mm (TC=4mm). Fan characteristics tests were carried out for two cases of TC size and three-dimensional velocity fields at rotor outlet were measured using a single slant hot-wire probe at four flow-rate conditions. As a result, it was found that the pressure -flow-rate characteristics curves for two cases showed almost the same tendency. However, the ensemble averaged velocity profiles along radial measurement stations of TC=4mm largely changed compared with that of TC=1mm in cases of small flow-rate condition. From the phase-locked averaging results, it was also found that the vortex existed in the rotor outlet flow field of high flow-rate condition for each TC case. Compared with the vortices for TC=1mm and TC=4mm, the vortex for TC=4mm was stronger than that for TC=1mm.

  1. Axial Myopia Is Associated with Visual Field Prognosis of Primary Open-Angle Glaucoma.

    Directory of Open Access Journals (Sweden)

    Chen Qiu

    Full Text Available To identify whether myopia was associated with the visual field (VF progression of primary open-angle glaucoma (POAG.A total of 270 eyes of 270 POAG followed up for more than 3 years with ≥9 reliable VFs by Octopus perimetry were retrospectively reviewed. Myopia was divided into: mild myopia (-2.99 diopter [D], 0, moderate myopia (-5.99, 3.00 D, marked myopia (-9.00, -6.00 D and non-myopia (0 D or more. An annual change in the mean defect (MD slope >0.22 dB/y and 0.30 dB/y was defined as fast progression, respectively. Logistic regression was performed to determine prognostic factors for VF progression.For the cutoff threshold at 0.22 dB/y, logistic regression showed that vertical cup-to-disk ratio (VCDR; p = 0.004 and the extent of myopia (p = 0.002 were statistically significant. When logistic regression was repeated after excluding the extent of myopia, axial length (AL; p = 0.008, odds ratio [OR] = 0.796 reached significance, as did VCDR (p = 0.001. Compared to eyes with AL≤23 mm, the OR values were 0.334 (p = 0.059, 0.309 (p = 0.044, 0.266 (p = 0.019, 0.260 (p = 0.018, respectively, for 23 26 mm. The significance of vertical cup-to-disk ratio of (p = 0.004 and the extent of myopia (p = 0.008 did not change for the cutoff threshold at 0.30dB/y.VCDR and myopia were associated with VF prognosis of POAG. Axial myopia may be a protective factor against VF progression.

  2. Study of Magnetic Field Behavior at Lower Pressure of Neon in the Axial Phase of INTI Plasma Focus

    Directory of Open Access Journals (Sweden)

    K.K.A. Devi

    2014-03-01

    Full Text Available The magnetic field distribution substantially affects mechanisms for the generation of radiation in Z-pinches. Investigation of the axial component of the magnetic field is one of the important problems in plasma focus studies. The designed magnetic probe is intended to use for the study of current sheet in INTI plasma focus device with energy of about 3.3 kJ. The measurements of the azimuthal component of the magnetic field on the INTI Plasma Focus operated at neon pressures below 1 Torr was carried out using a custom built calibrated magnetic probe. The probe was tested for neon gas under the various lower pressures (i.e., 0.1, 0.3, 0.5 and 0.7, 1, 2, 3, 5 torr etc.. It is observed that the time response of the designed probe is sufficient for the rise time of the magnetic field associated with the current in the axial phase. We also note that the small size of the designed probe is well suited to sense the magnetic field without perturbing the plasma unduly. The probe designed and constructed is also suitable to carryout measurements to obtain axial distributions of trajectory, average axial velocity and magnetic field of the current sheath at a certain radial distances along the axis of the tube.

  3. Vacuum effects in magnetic field with with account for fermion anomalous magnetic moment and axial-vector interaction

    Science.gov (United States)

    Bubnov, Andrey; Gubina, Nadezda; Zhukovsky, Vladimir

    2016-05-01

    We study vacuum polarization effects in the model of Dirac fermions with additional interaction of an anomalous magnetic moment with an external magnetic field and fermion interaction with an axial-vector condensate. The proper time method is used to calculate the one-loop vacuum corrections with consideration for different configurations of the characteristic parameters of these interactions.

  4. Sensitivity assessment of wide Axial Field of View PET systems via Monte Carlo simulations of NEMA-like measurements

    International Nuclear Information System (INIS)

    The sensitivity characteristics of Positron Emission Tomography (PET) systems with wide Axial Field of View (AFOV) was studied by MonteCarlo simulations complemented by an approximate analytical model, aiming at full-body human PET systems with AFOV in the order of 200 cm. Simulations were based on the GEANT4 package and followed closely the NEMA NU-2 1994 norm. The sensitivity, dominated by the solid angle, grows strongly with the AFOV and with the axial acceptance angle, while the scatter fraction is almost independent from the geometry

  5. Solving outside-axial-field-of-view scatter correction problem in PET via digital experimentation

    Science.gov (United States)

    Andreyev, Andriy; Zhu, Yang-Ming; Ye, Jinghan; Song, Xiyun; Hu, Zhiqiang

    2016-03-01

    Unaccounted scatter impact from unknown outside-axial-field-of-view (outside-AFOV) activity in PET is an important degrading factor for image quality and quantitation. Resource consuming and unpopular way to account for the outside- AFOV activity is to perform an additional PET/CT scan of adjacent regions. In this work we investigate a solution to the outside-AFOV scatter problem without performing a PET/CT scan of the adjacent regions. The main motivation for the proposed method is that the measured random corrected prompt (RCP) sinogram in the background region surrounding the measured object contains only scattered events, originating from both inside- and outside-AFOV activity. In this method, the scatter correction simulation searches through many randomly-chosen outside-AFOV activity estimates along with known inside-AFOV activity, generating a plethora of scatter distribution sinograms. This digital experimentation iterates until a decent match is found between a simulated scatter sinogram (that include supposed outside-AFOV activity) and the measured RCP sinogram in the background region. The combined scatter impact from inside- and outside-AFOV activity can then be used for scatter correction during final image reconstruction phase. Preliminary results using measured phantom data indicate successful phantom length estimate with the method, and, therefore, accurate outside-AFOV scatter estimate.

  6. Optical signatures of dissolved organic matter from the Endeavour and Axial vent fields

    Science.gov (United States)

    Stubbins, A.; Butterfield, D.; Rossel, P. E.; Dittmar, T.

    2011-12-01

    Recent studies have revealed that hydrothermal systems in the deep ocean are both sources and processors of dissolved organic matter (DOM). Sub-floor stores of fossil organic carbon may be exported to the deep ocean directly adding fossil C to the deep ocean dissolved organic carbon (DOC) pool and altering its apparent age. Fossil methane and carbon dioxide are also exported from vents. These C sources can then be utilized by chemotrophs and later enter the DOM pool as fossil DOC. Finally, when deep ocean waters are entrained into vent systems, the resultant heating may alter the chemical and optical properties of the DOM in these deep ocean waters. Dissolved organic matter (DOM) samples were collected from vents ranging in temperature from 10 to over 300 degrees centigrade across the Endeavour and Axial fields along the Juan de Fuca ridge. Elevated DOC and protein-like fluorescence reveal the vents to fuel the chemotrophic production of organic matter either in the adjacent water column or local sediments. High DOC and increased humic-like fluorescence in the hottest vent fluids, suggests the thermal degradation of DOM either from buried fossil sources or the entrainment of local waters enriched in DOC due to chemotrophic productivity. Natural and radio-carbon analyses are underway and will provide further insight into the ultimate source of this colored, fluorescent hydrothermal DOM.

  7. Field test of a thermal quadrupole mass spectrometer for safeguards verification

    International Nuclear Information System (INIS)

    A thermal ionization quadrupole mass spectrometer (Finnigan MAT) was tested in the Safeguards Analytical Laboratory of the IAEA with a view to evaluating its potential field applications. Several modifications have been introduced by the manufacturer. The instrument is equipped with an electron multiplier system and a Faraday cup detector. It allows fully automated analysis. Loadings of 1 μg U and 50 ng Pu can be measured without any problem. (author)

  8. Axial anomaly in the presence of the Aharonov-Bohm gauge field

    International Nuclear Information System (INIS)

    The axial anomaly for Euclidean Dirac fermions in the presence of a background Aharonov-Bohm gauge potential was computed. The non-perturbative result depends on the self-adjoint extensions of the Dirac operator. The role of the quantum mechanical parameters involved in the expression for the axial anomaly is discussed. A derivation of the effective action by means of the stereographic projection is also considered. (authors). 14 refs

  9. Influence of the Ion Source Operating Conditions on the Characteristics of a Prism Mass Spectrometer With Inhomogeneous Magnetic Field

    Directory of Open Access Journals (Sweden)

    P.O. Kuzema

    2010-01-01

    Full Text Available The influence of magnetic field focusing the electron beam in ion source of mass spectrometer on the analytical characteristics of the instrument has been studied. The range of current of ion source's focusing electromagnet providing the optimal performance of the mass spectrometer has been determined.

  10. Nonlocal vibration of axially moving graphene sheet resting on orthotropic visco-Pasternak foundation under longitudinal magnetic field

    Science.gov (United States)

    Arani, A. Ghorbanpour; Haghparast, E.; BabaAkbar Zarei, H.

    2016-08-01

    In the present research, vibration and instability of axially moving single-layered graphene sheet (SLGS) subjected to magnetic field is investigated. Orthotropic visco-Pasternak foundation is developed to consider the influences of orthotropy angle, damping coefficient, normal and shear modulus. Third order shear deformation theory (TSDT) is utilized due to its accuracy of polynomial functions than other plate theories. Motion equations are obtained by means of Hamilton's principle and solved analytically. Influences of various parameters such as axially moving speed, magnetic field, orthotropic viscoelastic surrounding medium, thickness and aspect ratio of SLGS on the vibration characteristics of moving system are discussed in details. The results indicated that the critical speed of moving SLGS is strongly dependent on the moving speed. Therefore, the critical speed of moving SLGS can be improved by applying magnetic field. The results of this investigation can be used in design and manufacturing of marine vessels in nanoscale.

  11. Frequency- and axial-field-dependent circular magnetization reversal in a stress-annealed Fe-based nanocrystalline wire

    International Nuclear Information System (INIS)

    Absract: After suitable annealing under a tensile stress, Fe73.5Cu1Nb3Si13.5B9 amorphous wire becomes the nano-structured material together with a transverse anisotropy field Hk=-3.2 kA/m. Its circular permeability, μ=μ'-jμ'', was determined from the measurements of the impedance, as a function of the frequency (f=333-33,333 Hz) and amplitude (IAC=0.1-100 mA) of AC current and the axially applied DC field (H=0-89 kA/m). We found that the circular technical magnetization of this sample carried out by the spontaneous domain nucleation process. The influences of the AC current frequency and the axial DC field on the circular magnetization have been studied

  12. Computer program for the relativistic mean field description of the ground state properties of even-even axially deformed nuclei

    CERN Document Server

    Ring, P; Lalazissis, G A

    1997-01-01

    A Fortran program for the calculation of the ground state properties of axially deformed even-even nuclei in the relativistic framework is presented. In this relativistic mean field (RMF) approach a set of coupled differential equations namely the Dirac equation with potential terms for the nucleons and the Glein-Gordon type equations with sources for the meson and the electromagnetic fields are to be solved self-consistently. The well tested basis expansion method is used for this purpose. Accordingly a set of harmonic oscillator basis generated by an axially deformed potential are used in the expansion. The solution gives the nucleon spinors, the fields and level occupancies, which are used in the calculation of the ground state properties.

  13. To the theory of heating of collisional plasma by means of magnetic pumping by axial-asymmetric variable fields

    International Nuclear Information System (INIS)

    Collisional heating of an inhomogeneous plasma cylinder with the help of magnetic pumping by axial-asymmetrical alternating fields, passing along a constant magnetic field with the phase velocity ω/K11 exceeding or of the order of sound velocity Vsub(s), has been considered. The heating rate is found for a low-pressure magnetized plasma. It is the same by the order of magnitude as the rate of heating by axial-symmetrical fields. In the case of the acoustic resonance (ω approximately K11 Vsub(s)) the energy absorption rate increases by a factor of 1/ωtausub(i)>>1, provided the resonance occurs in a narrow layer, and by a factor of 1/(ωtausub(i))2, provided the resonance occurs in the whole volume of plasma (tausub(i)sup(-1) is the frequency of ion-ion collisions)

  14. Precision system of the magnetic field stabilization of mass-spectrometer

    International Nuclear Information System (INIS)

    Full text: In the report the development of the magnetic field stabilization system of the INP AS RUz mass - spectrometer, created on the basis of the device Sh-1-1, is presented [1]. The necessity for such development was caused by a moral and physical deterioration of the existing equipment. Existing system of the mass- spectrometer magnetic field stabilization already qualitatively did not correspond to the requirements of experiments directed on search not enough of intensive modes of heavy nuclei fission under action of reactor neutrons [2]. Such experiments require for the statistical accuracy of long expositions and, hence, of maintenance of the magnetic field stability in limits ± 0,001% - ± 0,002 % in a working range from 0,15 T up to 0,6 T and the necessity in the precision system of the mass - spectrometer magnetic field stabilization is obvious. For the decision of a task the variant of a compound power unit (PU) with three-step system of magnetic field stabilization on its basis was chosen, thus all three steps of the magnetic field stabilization system is worked on the basic winding of an electromagnet. The feed of PU is carried out from a network of 220 V with the entrance step of the crude stabilization on the basis of the electromechanical regulator, which the shaft is set in motion by the electric motor. Signals of the control of the electric motor are manufactured by the watch scheme. The first and second step of stabilization provide installation and maintenance of constant value of a feed current of a winding with accuracy not worse than 0,1 %. The function of stabilization with required accuracy of a magnetic field in a backlash of magnetic system is provided with the third step of stabilization. For maintenance of required accuracy of measurement of a magnetic field induction in a working backlash of a magnet by us was modified standard device Sh1-1, and the block of quartz stabilization of the frequency of generator (BQSGF) for given

  15. Noncontact measurement of electrostatic fields: Verification of modeled potentials within ion mobility spectrometer drift tube designs

    International Nuclear Information System (INIS)

    The heart of an ion mobility spectrometer is the drift region where ion separation occurs. While the electrostatic potentials within a drift tube design can be modeled, no method for independently validating the electrostatic field has previously been reported. Two basic drift tube designs were modeled using SIMION 7.0 to reveal the expected electrostatic fields: (1) A traditional alternating set of electrodes and insulators and (2) a truly linear drift tube. One version of the alternating electrode/insulator drift tube and two versions of linear drift tubes were then fabricated. The stacked alternating electrodes/insulators were connected through a resistor network to generate the electrostatic gradient in the drift tube. The two linear drift tube designs consisted of two types of resistive drift tubes with one tube consisting of a resistive coating within an insulating tube and the other tube composed of resistive ferrites. The electrostatic fields within each type of drift tube were then evaluated by a noncontact method using a Kelvin-Zisman type electrostatic voltmeter and probe (results for alternative measurement methods provided in supplementary material). The experimental results were then compared with the electrostatic fields predicted by SIMION. Both the modeling and experimental measurements reveal that the electrostatic fields within a stacked ion mobility spectrometer drift tube are only pseudo-linear, while the electrostatic fields within a resistive drift tube approach perfect linearity

  16. Development and field tests of a narrowband all-reflective spatial heterodyne spectrometer.

    Science.gov (United States)

    Corliss, J B; Harris, W M; Mierkiewicz, E J; Roesler, F L

    2015-10-20

    We describe the design, development, and performance of a narrowband, all-reflective, unaliased spatial heterodyne spectrometer (SHS) that has been tested in observations at the focus of the 1.6 m main telescope of the McMath-Pierce solar telescope on Kitt Peak. The all-reflective SHS described herein is a highly robust common-path Fourier transform spectrometer without moving parts that, over a limited spectral region, combines the large field of view and high resolving power characteristic of interference spectrometers but at substantially reduced instrument size and optical tolerances. The self-scanned region of wavelength space and resolving power of the SHS are determined by the beam size, the diffraction grating groove density, the number of detector elements, and the fixed orientation of a set of pilot mirrors. The results presented here represent the first successful implementation of this reflective SHS design for field use. We discuss concepts behind the unaliased reflective SHS design and report the performance of the instrument when used to observe terrestrial airglow and absorption features, the solar spectrum, and the Jovian spectrum near λ=6300  Å, at the achieved resolving power (R=λ/δλ) of R>100,000. The results confirm that reflective SHS instruments can deliver effective interferometric performance in the visible to the far-ultraviolet wavelengths with commercial optics of moderate surface quality. PMID:26560368

  17. Portable scintillation gamma-spectrometer for field measurement of radioactivity in extensive objects

    International Nuclear Information System (INIS)

    The portable scintillated gamma-spectrometer for field measurement of radioactivity in the volume objects was designed. The crystal CdWO4 that has weak dependence of light yield from temperature in combination with PMT was applied as the gamma-rays detector. The design of the device provides the possibility for measuring radioactivity of the extensive objects in 4π-geometry without background measurements. In this case the value of the efficiency needed for specific activity calculation in close approximation depends only from crystal geometry and density of measuring object and may be set as the device parameter without efficiency calibration procedure during the operation. The spectrometer does not have an auxiliary radio-active source and connecting cables in the composition. The smartphone operated under Windows Mobile is used as the control module. Bluetooth connection provides data exchange between smartphone and measurement head.

  18. Design of combined magnetic field system for magnetic-bottle time-of-flight spectrometer

    International Nuclear Information System (INIS)

    Based on the primary requirement for the magnetic field system in magnetic-bottle time-of-flight spectrometer, an appropriate combined inhomogeneous magnetic field system is designed. The inhomogeneous higher magnetic field part, with the highest field of 1.2 T, is produced by the combination of a permanent magnet and a pole piece with optimized shape. The magnet,known as NdFeB magnet,is one of rare earth permanent magnets in N52. The guiding uniform magnetic field of 1.0 x 10-3 T is provided by solenoid, with length of 3 m and radius of 3 cm. The pitch between the pole piece and the near end of used solenoid is determined to be 5 cm, which can satisfy the actual engineering needs. (authors)

  19. Weaker axially dipolar time-averaged paleomagnetic field based on multidomain-corrected paleointensities from Galapagos lavas.

    Science.gov (United States)

    Wang, Huapei; Kent, Dennis V; Rochette, Pierre

    2015-12-01

    The geomagnetic field is predominantly dipolar today, and high-fidelity paleomagnetic mean directions from all over the globe strongly support the geocentric axial dipole (GAD) hypothesis for the past few million years. However, the bulk of paleointensity data fails to coincide with the axial dipole prediction of a factor-of-2 equator-to-pole increase in mean field strength, leaving the core dynamo process an enigma. Here, we obtain a multidomain-corrected Pliocene-Pleistocene average paleointensity of 21.6 ± 11.0 µT recorded by 27 lava flows from the Galapagos Archipelago near the Equator. Our new result in conjunction with a published comprehensive study of single-domain-behaved paleointensities from Antarctica (33.4 ± 13.9 µT) that also correspond to GAD directions suggests that the overall average paleomagnetic field over the past few million years has indeed been dominantly dipolar in intensity yet only ∼ 60% of the present-day field strength, with a long-term average virtual axial dipole magnetic moment of the Earth of only 4.9 ± 2.4 × 10(22) A ⋅ m(2). PMID:26598664

  20. Self-consistent calculation for the transport of intense pulsed beams in axial-symmetrical electrostatic fields

    CERN Document Server

    Li Chao Long; Lu Jian Qin

    2003-01-01

    A program for calculating intense pulsed beams transport in axial-symmetrical electrostatic fields is designed. The program can calculate beam optical systems consisting of the following elements: drift spaces, three-cylinder einzel lenses, three-diaphragm einzel lenses, electrostatic accelerating tubes, as well as two-cylinder lenses. In the calculations, the effective fields of each lens are divided into several small intervals, and each interval is treated as a uniform accelerating field, each dividing point is considered as a thin lens, and iterations are used to get self-consistent solutions. Iteration procedures are incorporated in the codes to get self-consistent solutions

  1. Characterization of electromagnetic fields in the aSPECT spectrometer and reduction of systematic errors

    Energy Technology Data Exchange (ETDEWEB)

    Ayala Guardia, Fidel

    2011-10-15

    The aSPECT spectrometer has been designed to measure, with high precision, the recoil proton spectrum of the free neutron decay. From this spectrum, the electron antineutrino angular correlation coefficient a can be extracted with high accuracy. The goal of the experiment is to determine the coefficient a with a total relative error smaller than 0.3%, well below the current literature value of 5%. First measurements with the aSPECT spectrometer were performed in the Forschungs-Neutronenquelle Heinz Maier-Leibnitz in Munich. However, time-dependent background instabilities prevented us from reporting a new value of a. The contents of this thesis are based on the latest measurements performed with the aSPECT spectrometer at the Institut Laue-Langevin (ILL) in Grenoble, France. In these measurements, background instabilities were considerably reduced. Furthermore, diverse modifications intended to minimize systematic errors and to achieve a more reliable setup were successfully performed. Unfortunately, saturation effects of the detector electronics turned out to be too high to determine a meaningful result. However, this and other systematics were identified and decreased, or even eliminated, for future aSPECT beamtimes. The central part of this work is focused on the analysis and improvement of systematic errors related to the aSPECT electromagnetic fields. This work yielded in many improvements, particularly in the reduction of the systematic effects due to electric fields. The systematics related to the aSPECT magnetic field were also minimized and determined down to a level which permits to improve the present literature value of a. Furthermore, a custom NMR-magnetometer was developed and improved during this thesis, which will lead to reduction of magnetic field-related uncertainties down to a negligible level to determine a with a total relative error of at least 0.3%.

  2. Field and frequency modulated sub-THz electron spin resonance spectrometer

    Science.gov (United States)

    Caspers, Christian; da Silva, Pedro Freire; Soundararajan, Murari; Haider, M. Ali; Ansermet, Jean-Philippe

    2016-05-01

    260-GHz radiation is used for a quasi-optical electron spin resonance (ESR) spectrometer which features both field and frequency modulation. Free space propagation is used to implement Martin-Puplett interferometry with quasi-optical isolation, mirror beam focusing, and electronic polarization control. Computer-aided design and polarization pathway simulation lead to the design of a compact interferometer, featuring lateral dimensions less than a foot and high mechanical stability, with all components rated for power levels of several Watts suitable for gyrotron radiation. Benchmark results were obtained with ESR standards (BDPA, DPPH) using field modulation. Original high-field ESR of 4f electrons in Sm3+-doped Ceria was detected using frequency modulation. Distinct combinations of field and modulation frequency reach a signal-to-noise ratio of 35 dB in spectra of BDPA, corresponding to a detection limit of about 1014 spins.

  3. Axial buckling analysis of a slender current-carrying nanowire acted upon by a magnetic field using the surface energy approach

    International Nuclear Information System (INIS)

    The axial buckling behavior of magnetically affected current-carrying nanowires is studied accounting for the surface energy effect. Using Euler–Bernoulli beam theory, the Lorentz force on the nanowire is determined and the governing equations are established. By application of the Galerkin approach and assumed mode method, the critical axial compressive load of the nanostructure is evaluated in the cases of simply supported and fully clamped ends. The effects of surface energy, electric current, strength of the magnetic field, slenderness ratio, and nanowire’s radius on the axial buckling loads are comprehensively discussed. The obtained results reveal that both the electric current and exerted magnetic field endanger the axial stability of the nanowire. For high levels of electric current or magnetic field strength, the surface effect becomes significant in the axial buckling performance of the nanostructure. (paper)

  4. Momentum reconstruction procedure for a nonfocusing spectrometer with wide-aperture analyzing magnet and nonuniform field

    International Nuclear Information System (INIS)

    The SPES-4 spectrometer at SATURNE II has recently been equipped with a detection system working in coincidence with it. This system uses a wide-aperture dipole magnet. A method is described to determine the momentum vector and interaction vertex of the detected charged particle from its trajectory parameters measured outside the inhomogeneous field of the magnet. The feature of the set-up is that all detectors are placed outside the dipole field, while the target is inside the ∼ 1 T field and the incoming track is not measured. The feature of the method is that it is simple and fast, while it uses only the straight line part of the particle trajectory, which can be measured with sufficient accuracy

  5. Ultralow power complementary inverter circuits using axially doped p- and n-channel Si nanowire field effect transistors

    Science.gov (United States)

    van, Ngoc Huynh; Lee, Jae-Hyun; Whang, Dongmok; Kang, Dae Joon

    2016-06-01

    We have successfully synthesized axially doped p- and n-type regions on a single Si nanowire (NW). Diodes and complementary metal-oxide-semiconductor (CMOS) inverter devices using single axial p- and n-channel Si NW field-effect transistors (FETs) were fabricated. We show that the threshold voltages of both p- and n-channel Si NW FETs can be lowered to nearly zero by effectively controlling the doping concentration. Because of the high performance of the p- and n-type Si NW channel FETs, especially with regard to the low threshold voltage, the fabricated NW CMOS inverters have a low operating voltage (DOI: 10.1039/c6nr01040g

  6. High energy micro electron beam generation using chirped laser pulse in the presence of an axial magnetic field

    International Nuclear Information System (INIS)

    In this paper, the generation of high-quality and high-energy micro electron beam in vacuum by a chirped Gaussian laser pulse in the presence of an axial magnetic field is numerically investigated. The features of energy and angular spectra, emittances, and position distribution of electron beam are compared in two cases, i.e., in the presence and absence of an external magnetic field. The electron beam is accelerated with higher energy and qualified in spatial distribution in the presence of the magnetic field. The presence of an axial magnetic field improves electron beam spatial quality as well as its gained energy through keeping the electron motion parallel to the direction of propagation for longer distances. It has been found that a 64 μm electron bunch with about MeV initial energy becomes a 20 μm electron beam with high energy of the order of GeV, after interacting with a laser pulse in the presence of an external magnetic field

  7. High energy micro electron beam generation using chirped laser pulse in the presence of an axial magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Akou, H., E-mail: h.akou@nit.ac.ir; Hamedi, M. [Department of Physics, Faculty of Basic Science, Babol University of Technology, Babol 47148-71167 (Iran, Islamic Republic of)

    2015-10-15

    In this paper, the generation of high-quality and high-energy micro electron beam in vacuum by a chirped Gaussian laser pulse in the presence of an axial magnetic field is numerically investigated. The features of energy and angular spectra, emittances, and position distribution of electron beam are compared in two cases, i.e., in the presence and absence of an external magnetic field. The electron beam is accelerated with higher energy and qualified in spatial distribution in the presence of the magnetic field. The presence of an axial magnetic field improves electron beam spatial quality as well as its gained energy through keeping the electron motion parallel to the direction of propagation for longer distances. It has been found that a 64 μm electron bunch with about MeV initial energy becomes a 20 μm electron beam with high energy of the order of GeV, after interacting with a laser pulse in the presence of an external magnetic field.

  8. Cold cathode field emitter array on a quadrupole mass spectrometer: Route to miniaturization

    International Nuclear Information System (INIS)

    We have improved the quadrupole mass spectrometer by substituting the conventional hot filament electron source by a field emitter array (FEA). Elimination of the hot filament avoids a number of common problems, including thermal cracking of delicate molecules, outgassing of the filament itself and nearby components, high power requirements for the filament, large size, stray light, stray magnetic fields, contamination by thoria and tungsten, and a long warm-up time. The advantages are clearest for portable applications where power requirements dominate. Here, the power savings are not just in eliminating the filament supply, but more important in reducing the largest component of the system, the vacuum pump. This comes about because the filament is the primary gas load and because chemical reactions taking place on it require fast pumping to keep the products from interfering with the spectra. Comparison between hot filament and cold cathode FEA ionization is made using a quadrupole mass spectrometer fitted with both electron sources, independently controlled. The FEA advantage is strongest when the ultrahigh vacuum system is throttled to a low pumping speed, mimicking a portable system with a small pump. FEAs also enable miniaturization and a corresponding decrease in pump size. Moreover, with miniaturization, shorter mean free paths and consequently higher working pressures can be tolerated further decreasing pump requirements. copyright 1999 American Vacuum Society

  9. Boundary-value problem for a counterrotating electrical discharge in an axial magnetic field. [plasma centrifuge for isotope separation

    Science.gov (United States)

    Hong, S. H.; Wilhelm, H. E.

    1978-01-01

    An electrical discharge between two ring electrodes embedded in the mantle of a cylindrical chamber is considered, in which the plasma in the anode and cathode regions rotates in opposite directions under the influence of an external axial magnetic field. The associated boundary-value problem for the coupled partial differential equations describing the azimuthal velocity and radial current-density fields is solved in closed form. The velocity, current density, induced magnetic induction, and electric fields are presented for typical Hartmann numbers, magnetic Reynolds numbers, and geometry parameters. The discharge is shown to produce anodic and cathodic plasma sections rotating at speeds of the order 1,000,000 cm/sec for conventional magnetic field intensities. Possible application of the magnetoactive discharge as a plasma centrifuge for isotope separation is discussed.

  10. Strains and axial outflows in the field of a rotating black hole

    CERN Document Server

    Bini, Donato; Geralico, Andrea

    2014-01-01

    We study the behaviour of an initially spherical bunch of accelerated particles emitted along trajectories parallel to the symmetry axis of a rotating black hole. We find that, under suitable conditions, curvature and inertial strains compete to model the shape of axial outflows of matter contributing to generate jet-like structures. This is of course a purely kinematical effect which does not account by itself for physical processes underlying the formation of jets. In our analysis a crucial role is played by a property of the electric and magnetic part of the Weyl tensor to be Lorentz-invariant boosting along the axis of symmetry in Kerr spacetime.

  11. The Concurrent Track Evolution algorithm: extension for track finding in the inhomogeneous magnetic field of the HERA-B spectrometer

    International Nuclear Information System (INIS)

    The Concurrent Track Evolution method, which was introduced in a previous paper (Mankel, Nucl. Instr. and Meth. A 395 (1997) 169), has been further explored by applying it to the propagation of track candidates into an inhomogeneous magnetic field volume equipped with tracking detectors, as is typical for forward B spectrometers like HERA-B or LHCb. Compared to the field-free case, the method was extended to three-dimensional propagation, with special measures necessary to achieve fast transport in the presence of a highly variable magnetic field. The performance of the method is tested on HERA-B Monte Carlo events with full detector simulation and a realistic spectrometer geometry

  12. Experimental study of flow field in interference area between impeller and guide vane of axial flow pump

    Institute of Scientific and Technical Information of China (English)

    张华; 施卫东; 陈斌; 曹卫东; 张启华

    2014-01-01

    Axial flow pump is a kind of typical pumps with rotor-stator interaction, thus the measurement of the flow field between impeller and guide vane would facilitate the study of the internal rotor-stator interaction mechanism. Through a structural modifi-cation of a traditional axial flow pump, the requirements of particle image velocimetry (PIV) measurement are met. Under the condition of opt.0.8Q , the axial vortex is identified between impeller hub and guide vane hub, which is developed into the main flow and to affect the movement when the relative positions of impeller and guide vane at different flow rates are the same. Besides, the development and the dissipation of the tip leakage and the passage vortex in impeller passages are mainly responsible for the difference of the flow field close to the outer rim. As the flow rate decreases, the distribution of the meridional velocities at the impeller outlet becomes more non-uniform and the radial velocity component keeps increasing. The PIV measurement results under the condition of opt.1.0Q indicate that the flow separation and the trailing vortex at the trailing edge of a blade are likely to result in a velocity sudden change in this area, which would dramatically destroy the continuity of the flow field. Moreover, the radial direction of the flow between impeller and guide vane on the measurement plane does not always point from hub to rim. For a certain position, the direction is just from rim to hub, as is affected by the location of the intersection line of the shooting section and the impeller blade on the impeller as well as the angle between the intersection line and the rotating shaft.

  13. Definition of the radiation fields for the JET gamma-ray spectrometer diagnostics

    International Nuclear Information System (INIS)

    The JET gamma-ray diagnostics system provides information on the behaviour of fast particles within the tokamak plasma. Information on the spatial distribution of the interacting fast particles is obtained from the gamma-ray cameras, while energy distribution information is provided by gamma-ray spectrometers. These techniques have been successfully applied so far in fast particle simulation experiments at JET. The extension of these diagnostics to high performance discharges with high neutron yields is not straightforward due to the background gamma-ray emission induced by neutrons. Two gamma-ray diagnostics upgrade projects at JET addressed this issue by developing neutron/gamma radiation filters (“neutron attenuators”) and collimators for a proper definition of the radiation (neutron and gamma) fields along the diagnostics line-of-sight. A pair of neutron/gamma collimators working in a tandem configuration have been designed and constructed for the JET quasi-tangential gamma-ray spectrometer. The tandem collimators were designed to provide shielding factors of about 5 × 102 for 2.45 MeV neutrons and about 103 for 9 MeV gamma-rays. The devices have been installed on the JET machine and the paper presents the first experimental results. A similar tandem collimator system was designed for deuterium-tritium experiments on JET. The results of neutron-photon transport calculations for 14.1 MeV neutrons are also presented

  14. GoAmazon 2014/15 Thermal Desorption Chemical Ionization Mass Spectrometer (TDCIMS) Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Smith, JN [Univ. of California, Irvine, CA (United States)

    2016-04-01

    The Thermal Desorption Chemical Ionization Mass Spectrometer (TDCIMS) deployment to the U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility T3 site in Manacapuru, Brazil, was motivated by two main scientific objectives of the Green Ocean Amazon (GoAmazon) 2014/15 field campaign. 1) Study the interactions between anthropogenic and biogenic emissions by determining important molecular species in ambient nanoparticles. To address this, TDCIMS data will be combined with coincident measurements such as gas-phase sulfuric acid to determine the contribution of sulfuric acid condensation to nucleation and growth. We can then compare that result to TDCIMS-derived nanoparticle composition to determine the fraction of growth that can be attributed to the uptake of organic compounds. The molecular composition of sampled particles will also be used to attribute specific chemical species and mechanisms to growth, such as the condensation of low-volatility species or the oligomerization of α-dicarbonyl compounds. 2) Determine the source of new ambient nanoparticles in the Amazon. The hypothesis prior to measurements was that potassium salts formed from the evaporation of primary particles emitted by fungal spores can provide a unique and important pathway for new particle production in the Amazon basin. To explore this hypothesis, the TDCIMS recorded the mass spectra of sampled ambient particles using a protonated water cluster Chemical Ionization Mass Spectrometer (CIMS). Laboratory tests performed using potassium salts show that the TDCIMS can detect potassium with high sensitivity with this technique.

  15. Observation of multipactor suppression in a dielectric-loaded accelerating structure using an applied axial magnetic field

    Science.gov (United States)

    Jing, C.; Chang, C.; Gold, S. H.; Konecny, R.; Antipov, S.; Schoessow, P.; Kanareykin, A.; Gai, W.

    2013-11-01

    Efforts by a number of institutions to develop a Dielectric-Loaded Accelerating (DLA) structure capable of supporting high gradient acceleration when driven by an external radio frequency source have been ongoing over the past decade. Single surface resonant multipactor has been previously identified as one of the major limitations on the practical application of DLA structures in electron accelerators. In this paper, we report the results of an experiment that demonstrated suppression of multipactor growth in an X-band DLA structure through the use of an applied axial magnetic field. This represents an advance toward the practical use of DLA structures in many accelerator applications.

  16. Observation of multipactor suppression in a dielectric-loaded accelerating structure using an applied axial magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Jing, C.; Konecny, R.; Antipov, S. [Euclid Techlabs, LLC, 5900 Harper Rd., Solon, Ohio 44139 (United States); High Energy Physics Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Chang, C. [Science and Technology on High Power Microwave Laboratory, Xi' an City 710024 (China); Institute of Energy, Tsinghua University, Beijing 100084 (China); Gold, S. H. [Naval Research Laboratory, Plasma Physics Division, Washington, DC 20375 (United States); Schoessow, P.; Kanareykin, A. [Euclid Techlabs, LLC, 5900 Harper Rd., Solon, Ohio 44139 (United States); Gai, W. [High Energy Physics Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States)

    2013-11-18

    Efforts by a number of institutions to develop a Dielectric-Loaded Accelerating (DLA) structure capable of supporting high gradient acceleration when driven by an external radio frequency source have been ongoing over the past decade. Single surface resonant multipactor has been previously identified as one of the major limitations on the practical application of DLA structures in electron accelerators. In this paper, we report the results of an experiment that demonstrated suppression of multipactor growth in an X-band DLA structure through the use of an applied axial magnetic field. This represents an advance toward the practical use of DLA structures in many accelerator applications.

  17. Computer Calculations of Eddy-Current Power Loss in Rotating Titanium Wheels and Rims in Localized Axial Magnetic Fields

    Energy Technology Data Exchange (ETDEWEB)

    Mayhall, D J; Stein, W; Gronberg, J B

    2006-05-15

    We have performed preliminary computer-based, transient, magnetostatic calculations of the eddy-current power loss in rotating titanium-alloy and aluminum wheels and wheel rims in the predominantly axially-directed, steady magnetic fields of two small, solenoidal coils. These calculations have been undertaken to assess the eddy-current power loss in various possible International Linear Collider (ILC) positron target wheels. They have also been done to validate the simulation code module against known results published in the literature. The commercially available software package used in these calculations is the Maxwell 3D, Version 10, Transient Module from the Ansoft Corporation.

  18. Test of the Bonner Sphere Spectrometer Response Matrix in the 252Cf Neutron Field

    International Nuclear Information System (INIS)

    Full text: Since its development in 1960, a Bonner sphere spectrometer (BSS) has been the only instrument, which enables the spectral neutron fluence to be measured in a wide range of energies from thermal up to 20 MeV. Its resolution is poor but sufficient for dosimetric specification of neutron fields at workplaces. Experimentally determined BSS count rates depends mainly on the accuracy of the response matrix characterising certain type of BSS. At presemt the BSS response matrices are calculate by neutron transport Monte Carlo codes which allow detailed description of the BSS setup. The best verification of calculated response matrix is a calibration of the BSS in fields of monoenergetic neutrons. As so as these fields are not simply achievable a simple method how to test quality of BSS response matrix in the neutron field of 252Cf source is described. Applying distance variation method we get count rates of the BSS in the 252Cf field from which contributions of scattered neutrons and influence of finite detector and source dimensions were removed. These count rates are compared with the integrals of pure 252Cf spectrum and responses for individual spheres of the BSS. Disagreement indicates for which sphere the response is not properly determined. (author)

  19. Nuclear magnetic resonance at millitesla fields using a zero-field spectrometer

    Science.gov (United States)

    Tayler, Michael C. D.; Sjolander, Tobias F.; Pines, Alexander; Budker, Dmitry

    2016-09-01

    We describe new analytical capabilities for nuclear magnetic resonance (NMR) experiments in which signal detection is performed with chemical resolution (via spin-spin J couplings) in the zero to ultra-low magnetic field region, below 1 μT. Using magnetic fields in the 100 μT to 1 mT range, we demonstrate the implementation of conventional NMR pulse sequences with spin-species selectivity.

  20. Lie map for the nonlinear transport of continuous intense beams in the axial-symmetric electrostatic fields

    Institute of Scientific and Technical Information of China (English)

    Jianqin Lü; Xiaosong Zhao

    2008-01-01

    Nonlinear transport of intense continuous beam in the axial-symmetric electrostatic fields is analyzed with the Lie algebraic method.The K-V particle distribution is adopted in the analysis. The results obtained can be used in the calculations of the intense continuous beam dynamics in the beam optical systems consisting of drift spaces, electrostatic lenses, and DC electrostatic accelerating tubes. A com-puter code has been designed for practical simulations. To meet the needs of accurate calculation, all the elements are divided into many small segments, the electric fields in each segment are regarded as uniform fields, and the dividing points are treated as thin lenses. Iter-ation procedures are adopted in the code to obtain self-consistent solutions. The code can be used to design low energy dc beam transport systems, electrostatic accelerators, and ion implantation machines.

  1. Probing strong field ionization of solids with a Thomson parabola spectrometer

    Indian Academy of Sciences (India)

    Malay Dalui; T Madhu Trivikram; Ram Gopal; M Krishnamurthy

    2014-01-01

    Intense ultrashort laser pulses are known to generate high-density, high-temperature plasma from any substrate. Copious emission of hot electrons, from a solid substrate, results in strong electrostatic field that accelerates the ions with energies ranging from a few eV to MeV. Ion spectrometry from laser–plasma is convolved with multiple atomic systems, several charge states and a broad energy spread. Conventional mass spectrometric techniques have serious limitations to probe this ionization dynamics. We have developed an imaging ion spectrometer that measures charge/mass-resolved ion kinetic energies over the entire range. Microchannel plate (MCP) is used as the position-sensitive detector to perform online and single shot measurements. The wellresolved spectrum even for the low-energy ions, demonstrates that the spectral width is limited by the space-charge repulsion for the ions generated in the hot dense plasma.

  2. Precipitation and Hydrology Experiment Counter-Flow Spectrometer and Impactor Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Poellot, Michael [University of North Dakota

    2016-03-01

    The U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility Aerial Facility (ARM AAF) counter-flow spectrometer and impactor (CSI) probe was flown on the University of North Dakota Cessna Citation research aircraft during the Integrated Precipitation and Hydrology Experiment (IPHEX). The field campaign took place during May and June of 2014 over North Carolina and its coastal waters as part of a National Aeronautics and Space Administration (NASA) Global Precipitation Measurement validation campaign. The CSI was added to the Citation instrument suite to support the involvement of Jay Mace through the NASA Advanced Composition Explorer (ACE) satellite program and flights of the NASA ER-2 aircraft, which is a civilian version of the Air Force’s U2-S reconnaissance platform. The ACE program funded extra ER-2 flights to focus on clouds that are weakly precipitating, which are also of interest to the Atmospheric System Research program sponsored by DOE.

  3. Primordial magnetic fields of non-minimal photon-torsion axial coupling origin

    CERN Document Server

    de Andrade, Garcia

    2010-01-01

    Dynamo action is shown to be induced from homogeneous non-minimal photon-torsion axial coupling in the quantum electrodynamics (QED) framework in Riemann flat spacetime contortion decays. The geometrical optics in Riemann-Cartan spacetime is considering and a plane wave expansion of the electromagnetic vector potential is considered leading to a set of the equations for the ray congruence. Since we are interested mainly on the torsion effects in this first report we just consider the Riemann-flat case composed of the Minkowskian spacetime with torsion. It is also shown that in torsionic de Sitter background the vacuum polarisation does alter the propagation of individual photons, an effect which is absent in Riemannian spaces. It is shown that the cosmological torsion background inhomogeneities induce Lorentz violation and massive photon modes in this QED. Magnetic dynamos in this torsioned spacetime electrodynamics are simpler obtained in Fourier space than the cosmic ones, previously obtained by Bassett et ...

  4. Ferrofluid spiral formations and continuous-to-discrete phase transitions under simultaneously applied DC axial and AC in-plane rotating magnetic fields

    International Nuclear Information System (INIS)

    New flows and instabilities are presented for a ferrofluid drop contained in glass Hele-Shaw cells with simultaneously applied in-plane clockwise rotating and DC axial uniform magnetic fields. When a ferrofluid drop is stressed by a uniform DC axial magnetic field, up to ∼250 G in 0.9-1.4 mm gap Hele-Shaw cells, the drop forms a labyrinth pattern. With subsequent application of an in-plane uniform rotating magnetic field, up to ∼100 G rms at frequency 20-40 Hz, smooth spirals form from viscous shear due to ferrofluid flow. If the rotating magnetic field is applied first, the drop is held together without a labyrinth. Gradual increase of the DC axial magnetic field, to a critical magnetic field value, results in an abrupt phase transformation from a large drop to many small discrete droplets. A preliminary minimum magnetization and surface energy analysis is presented to model the phase transformation

  5. Design and commissioning of a high magnetic field muon spin relaxation spectrometer at the ISIS pulsed neutron and muon source.

    Science.gov (United States)

    Lord, J S; McKenzie, I; Baker, P J; Blundell, S J; Cottrell, S P; Giblin, S R; Good, J; Hillier, A D; Holsman, B H; King, P J C; Lancaster, T; Mitchell, R; Nightingale, J B; Owczarkowski, M; Poli, S; Pratt, F L; Rhodes, N J; Scheuermann, R; Salman, Z

    2011-07-01

    The high magnetic field (HiFi) muon instrument at the ISIS pulsed neutron and muon source is a state-of-the-art spectrometer designed to provide applied magnetic fields up to 5 T for muon studies of condensed matter and molecular systems. The spectrometer is optimised for time-differential muon spin relaxation studies at a pulsed muon source. We describe the challenges involved in its design and construction, detailing, in particular, the magnet and detector performance. Commissioning experiments have been conducted and the results are presented to demonstrate the scientific capabilities of the new instrument. PMID:21806196

  6. Design and commissioning of a high magnetic field muon spin relaxation spectrometer at the ISIS pulsed neutron and muon source

    Energy Technology Data Exchange (ETDEWEB)

    Lord, J. S.; McKenzie, I.; Baker, P. J.; Cottrell, S. P.; Giblin, S. R.; Hillier, A. D.; Holsman, B. H.; King, P. J. C.; Nightingale, J. B.; Pratt, F. L.; Rhodes, N. J. [ISIS Facility, STFC Rutherford Appleton Laboratory, Chilton, Oxon OX11 0QX (United Kingdom); Blundell, S. J.; Lancaster, T. [Clarendon Laboratory, Department of Physics, Oxford University, Parks Road, Oxford OX1 3PU (United Kingdom); Good, J.; Mitchell, R.; Owczarkowski, M.; Poli, S. [Cryogenic Limited, 30 Acton Park Industrial Estate, The Vale, Acton, London W3 7QE (United Kingdom); Scheuermann, R. [Laboratory for Muon Spin Spectroscopy, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Salman, Z. [ISIS Facility, STFC Rutherford Appleton Laboratory, Chilton, Oxon OX11 0QX (United Kingdom); Clarendon Laboratory, Department of Physics, Oxford University, Parks Road, Oxford OX1 3PU (United Kingdom)

    2011-07-15

    The high magnetic field (HiFi) muon instrument at the ISIS pulsed neutron and muon source is a state-of-the-art spectrometer designed to provide applied magnetic fields up to 5 T for muon studies of condensed matter and molecular systems. The spectrometer is optimised for time-differential muon spin relaxation studies at a pulsed muon source. We describe the challenges involved in its design and construction, detailing, in particular, the magnet and detector performance. Commissioning experiments have been conducted and the results are presented to demonstrate the scientific capabilities of the new instrument.

  7. Life estimation of low-cycle fatigue of pipe elbows. Proposed criteria of low-cycle fatigue life under the multi-axial stress field

    International Nuclear Information System (INIS)

    Pipe elbows were important parts frequently used in the pipelines of nuclear power, thermal power and chemical plants, and their integrity needed to be assured under seismic loads and thermal stresses considering local wall thinning or complex stress distribution due to special configuration different from straight pipe. This article investigated in details elastic-plastic stress-strain state of pipe elbow using finite element analysis and clarified there existed high bi-axial stress field at side inner surface of pipe elbow axial cracks initiated. Bi-axial stress factor was around 0.6 for sound elbow and up to 0.95 for local wall thinning at crown. Fracture strain of 1.15 was reduced to around 0.15 for bi-axial stress factor from 0.6 to 0.9. Normalized fatigue life for bi-axial stress field (0.6 - 0.8) was largely reduced to around 15, 19 and 10% of fatigue life of uni-axial state dependent on material strength level. Proposed revised universal slopes taking account of multi-axial stress factor could explain qualitatively effects of strain range, internal pressure and ratchet strain (pre-strain) on low-cycle fatigue life of pipe elbow. (T. Tanaka)

  8. a Simple, Cost Effective Raman-Fluorescence Spectrometer for Use in Laboratory and Field Experiments

    Science.gov (United States)

    Marshall, Frank E.; Pride, Michael A.; Rojo, Michellle; Brinker, Katelyn R.; Walker, Zachary; Storrie-Lombardi, Michael; Mormile, Melanie R.; Grubbs, G. S., II

    2015-06-01

    Research, design, construction, and operation of a portable mixed Raman and Fluorescence type spectrometer implemented by the Missouri University of Science and Technology's Mars Rover Design Team will be presented. This spectrometer has been built for the team's annual competition. The spectrometer, completely built by undergraduates, is designed to use a 50 mW, 532 nm constant waveform laser to probe a sample of soil to find bacteria or bio-markers. However, initial tests of the spectrometer were carried out in a laboratory environment making the spectrometer also suitable for simple undergraduate physical chemistry or chemical physics laboratory experiments. The final cost of the device is roughly 2100, weighs 1.4 kg, and is 22.9 cm x 22.6 cm in size. Integrating the spectrometer with a computer database, results from the competition, complications of fitting mixed Raman-Fluorescence spectra, and future ideas/improvements will also be discussed.

  9. Grazing incidence extreme ultraviolet spectrometer fielded with time resolution in a hostile Z-pinch environment

    International Nuclear Information System (INIS)

    This recently developed diagnostic was designed to allow for time-gated spectroscopic study of the EUV radiation (4 nm < λ < 15 nm) present during harsh wire array z-pinch implosions. The spectrometer utilizes a 25 μm slit, an array of 3 spherical blazed gratings at grazing incidence, and a microchannel plate (MCP) detector placed in an off-Rowland position. Each grating is positioned such that its diffracted radiation is cast over two of the six total independently timed frames of the MCP. The off-Rowland configuration allows for a much greater spectral density on the imaging plate but only focuses at one wavelength per grating. The focal wavelengths are chosen for their diagnostic significance. Testing was conducted at the Zebra pulsed-power generator (1 MA, 100 ns risetime) at University of Nevada, Reno on a series of wire array z-pinch loads. Within this harsh z-pinch environment, radiation yields routinely exceed 20 kJ in the EUV and soft x-ray. There are also strong mechanical shocks, high velocity debris, sudden vacuum changes during operation, energic ion beams, and hard x-ray radiation in excess of 50 keV. The spectra obtained from the precursor plasma of an Al double planar wire array contained lines of Al IX and AlX ions indicating a temperature near 60 eV during precursor formation. Detailed results will be presented showing the fielding specifications and the techniques used to extract important plasma parameters using this spectrometer.

  10. A phase-field approach to model multi-axial and microstructure dependent fracture in nuclear grade graphite

    Science.gov (United States)

    Chakraborty, Pritam; Sabharwall, Piyush; Carroll, Mark C.

    2016-07-01

    The fracture behavior of nuclear grade graphites is strongly influenced by underlying microstructural features such as the character of filler particles, and the distribution of pores and voids. These microstructural features influence the crack nucleation and propagation behavior, resulting in quasi-brittle fracture with a tortuous crack path and significant scatter in measured bulk strength. This study uses a phase-field method to model the microstructural and multi-axial fracture in H-451, a historic variant of nuclear graphite that provides the basis for an idealized study on a legacy grade. The representative volume elements are constructed from randomly located pores with random size obtained from experimentally determined log-normal distribution. The representative volume elements are then subjected to simulated multi-axial loading, and a reasonable agreement of the resulting fracture stress with experiments is obtained. Quasi-brittle stress-strain evolution with a tortuous crack path is also observed from the simulations and is consistent with experimental results.

  11. 轴流式血泵流场CFD仿真%Flow field CFD analysis of axial flow blood pump

    Institute of Scientific and Technical Information of China (English)

    谢雄; 谭建平

    2014-01-01

    In the development of axial flow blood pump,the arterial partial flow field may produce an area with very low flow shear rate,so it is necessary to consider the non-Newtonian charac-teristics of blood fluid.In this paper,a model of axial flow blood pump was established,and flow and rotate-speed’s impacts on the inlet and outlet of the flow field in the blood pump were ana-lyzed through Computational Fluid Dynamics (CFD)simulation,as wel as the influence of the guide vane on the flow field.By the pump water experiment of the designed blood pump,its out-put flow and pressure were measured;the results show that the designed blood pump is consist-ent on the law with the simulation.%在轴流式血泵的研发过程中,动脉局部流场中可能产生流动剪切率非常低的区域,因此有必要考虑血液的非牛顿特性。建立了轴流式血泵模型,通过CFD仿真分析得到血泵转速和流量的变化对血泵出入口压力分布和速度分布的影响,并采用水和甘油(2∶1)的混合流体替代血液,对设计的血泵进行驱动实验,测量了轴流式血泵输出流量和压力参数。结果表明:所设计的血泵在规律上和仿真是相符的。

  12. Novel pulsed switched power supply for a fast field cycling NMR spectrometer.

    Science.gov (United States)

    Sousa, D M; Fernandes, P A L; Marques, G D; Ribeiro, A C; Sebastião, P J

    2004-01-01

    In this paper, we outline the operating principles of a pulsed switched power supply for a fast field-cycling nuclear magnetic resonance spectrometer. The power supply uses a variant of a four-quadrant chopper with a duty cycle that defines the average output current. With this topology only two semiconductors are necessary to drive hundreds of amperes with an output power of several kilowatts. The output current ripple has a well-defined shape that can be reduced to acceptable values by a careful design of the semiconductors' controlling circuits and drivers. A power supply prototype was tested with a home build air-core magnet operating with fields between 0 and 0.21 T. The system is computer controlled using pulse generator and data acquisition PC cards, and specific user-friendly home-developed software. A comparative proton relaxometry study in two well-known liquid crystal compounds 5CB and MBBA was performed to check the reproducibility of the T1 measurements. PMID:14698404

  13. An automated field spectrometer system for studying VIS, NIR and SWIR anisotropy for semi-arid savanna

    DEFF Research Database (Denmark)

    Huber, Silvia; Tagesson, Håkan Torbern; Fensholt, Rasmus

    2014-01-01

    This paper presents the Dahra field spectrometer system (DAFIS) sited in Senegal, West Africa. DAFIS is a unique system that automatically measures the spectro-directional reflectance properties of a semi-arid savanna in the spectral range of 350–1800 nm, daily from sunrise to sunset. The instrum...

  14. Current-voltage characteristics of hydrogen DC plasma torches with different sizes in an external axial magnetic field

    Science.gov (United States)

    Ma, Jie; Wen, Guang-Dong; Su, Bao-Gen; Yang, Yi-Wen; Ren, Qi-Long

    2015-06-01

    Current-voltage (I-V) characteristics of hydrogen DC plasma torches with different sizes in an external axial magnetic field under atmospheric pressure are reported. Three anodes with different diameters are adopted in a 50-kW torch: 25 mm, 30 mm, and 35 mm, respectively. Two different diameters of anodes, that is, 100 mm and 130 mm, are adopted in a 1-MW plasma torch. The arc voltage shows a negative trend with the increase of arc current under the operating regimes. On the contrary, arc voltage shows a positive trend as the flow rate of carrier gas increases, and a similar trend is found with increasing the external magnetic flux density. A similarity formula is constructed to correlate the experimental data of the torches mentioned above. Linear fitting shows that the Pearson correlation coefficient is 0.9958. Project supported by the Special Fund for Basic Scientific Research of Central Colleges, China (Grant No. 2012FZA4023).

  15. Analysis of axially symmetric wire antennas by the use of exact kernel of electric field integral equation

    Directory of Open Access Journals (Sweden)

    Krneta Aleksandra J.

    2016-01-01

    Full Text Available The paper presents a new method for the analysis of wire antennas with axial symmetry. Truncated cones have been applied to precisely model antenna geometry, while the exact kernel of the electric field integral equation has been used for computation. Accuracy and efficiency of the method has been further increased by the use of higher order basis functions for current expansion, and by selecting integration methods based on singularity cancelation techniques for the calculation of potential and impedance integrals. The method has been applied to the analysis of a typical dipole antenna, thick dipole antenna and a coaxial line. The obtained results verify the high accuracy of the method. [Projekat Ministarstva nauke Republike Srbije, br. TR-32005

  16. Mossbauer Spectrometer for Measurements in High Magnetic Fields(Part II. Several Instruments and Techniques Developed in HFLSM)

    OpenAIRE

    Onodera, Hideya; Kato, Hiroaki; Kobayashi, Hisao; Iida, Junji; Miura, Shigeto; Yamamoto, Hisao; Nakagawa, Yasuaki

    1987-01-01

    A Mossbauer spectrometer has been designed and constructed for measurements in high magnetic fields beyond 20 T which are generated by a hybrid magnet in the High Field laboratory for Superconducting Materials at Tohoku University. Simple ways were adopted in order to avoid some obstacles for the spectroscopy. The most serious problem was electromagnetic inductions occurring at metallic components in a source drive system. It was found that the replacement of an aluminum drive-rod to a Bakeli...

  17. Thermal diffusion in a binary fluid mixture flows due to a rotating disc of uniform high suction in presence of a weak axial magnetic field

    Directory of Open Access Journals (Sweden)

    Sharma B.R.

    2010-01-01

    Full Text Available The effect of a weak uniform axial magnetic field on separation of a binary mixture of incompressible viscous thermally and electrically conducting fluids flowing due to a rotating disc of uniform high suction is examined. Neglecting the induced electric field the equations governing the motion, temperature and concentration are solved in cylindrical polar coordinate by expanding the flow parameters as well as the temperature and the concentration in powers of suction parameter. The solution obtained for concentration distribution is plotted against the different axial distances from the disc for various values of non-dimensional parameters. It is found that the temperature gradient, axial magnetic field, Reynolds number, Schmidt number, Prandtl number and suction parameter effect the species separation significantly.

  18. Pressure losses and flow field distortion induced by tip clearance of centrifugal and axial compressors

    Science.gov (United States)

    Senoo, Yasutoshi

    1987-03-01

    The flow field near the tip of compressor rotor blades is distorted by leakage through the tip clearance and the performance of the compressor is deteriorated. The literature regarding the tip clearance of compressor blades consists of computational fluid mechanics and experimental studies on the flow field and the pressure loss. Empirical equations expressing the pressure loss and the efficiency drop are varied. They relate to the lift coefficient in different ways, depending upon the ways of understanding the mechanics of pressure losses. These methods are examined and compared. Also, a brief discussion is made on the optimum value of the tip clearance.

  19. Field Observation of the Green Ocean Amazon. Neutral Cluster Air Ion Spectrometer (NAIS) Final Campaign Summary

    Energy Technology Data Exchange (ETDEWEB)

    Petaja, T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Backman, J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Manninen, H. E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wimmer, D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-03-01

    The neutral cluster and air ion spectrometer (NAIS) was deployed to the T3 site for Intensive Operations Periods 1 and 2 (IOP1 and IOP2). The NAIS is an instrument that measures aerosol particle and ion number size distributions in the mobility diameter range of 0.8 to 42 nm, corresponding to electrical mobility range between 3.2 and 0.0013 cm2 V-1 s-1. New particle formation (NPF) events were detected using the NAIS at the T3 field site during IOP1 and IOP2. Secondary NPF is a globally important source of aerosol number. To fully explain atmospheric NPF and subsequent growth, we need to directly measure the initial steps of the formation processes in different environments, including rain forest. Particle formation characteristics, such as formation and growth rates, were used as indicators of the relevant processes and participating compounds in the initial formation. In a case of parallel ion and neutral cluster measurements, we estimated the relative contribution of ion-induced and neutral nucleation to the total particle formation.

  20. Broadscale resolving power performance of a high precision uniform field ion mobility-mass spectrometer.

    Science.gov (United States)

    May, Jody C; Dodds, James N; Kurulugama, Ruwan T; Stafford, George C; Fjeldsted, John C; McLean, John A

    2015-10-21

    An extensive study of two current ion mobility resolving power theories ("conditional" and "semi-empirical") was undertaken using a recently developed drift tube ion mobility-mass spectrometer. The current study investigates the quantitative agreement between experiment and theory at reduced pressure (4 Torr) for a wide range of initial ion gate widths (100 to 500 μs), and ion mobility values (K0 from 0.50 to 3.0 cm(2) V(-1) s(-1)) representing measurements obtained in helium, nitrogen, and carbon dioxide drift gas. Results suggest that the conditional resolving power theory deviates from experimental results for low mobility ions (e.g., high mass analytes) and for initial ion gate widths beyond 200 μs. A semi-empirical resolving power theory provided close-correlation of predicted resolving powers to experimental results across the full range of mobilities and gate widths investigated. Interpreting the results from the semi-empirical theory, the performance of the current instrumentation was found to be highly linear for a wide range of analytes, with optimal resolving powers being accessible for a narrow range of drift fields between 14 and 17 V cm(-1). While developed using singly-charged ion mobility data, preliminary results suggest that the semi-empirical theory has broader applicability to higher-charge state systems. PMID:26191544

  1. A field-deployable gamma-ray spectrometer utilizing xenon at high pressure

    International Nuclear Information System (INIS)

    Prototype gamma-ray spectrometers utilizing xenon gas at high pressure, suitable for applications in the nuclear safeguards, arms control, and nonproliferation communities, have been developed at Brookhaven National Laboratory (BNL). These spectrometers function as ambient-temperature ionization chambers detecting gamma rays with good efficiency in the energy range 50 keV - 2 MeV, with an energy resolution intermediate between semiconductor (Ge) and scintillation (NaI) spectrometers. They are capable of prolonged, low-power operation without a requirement for cryogenic fluids or other cooling mechanisms, and with the addition of small quantities of 3He gas, can function simultaneously as efficient thermal neutron detectors

  2. A field-deployable, chemical ionization time-of-flight mass spectrometer

    Directory of Open Access Journals (Sweden)

    T. H. Bertram

    2011-07-01

    Full Text Available We constructed a new chemical ionization time-of-flight mass spectrometer (CI-TOFMS that measures atmospheric trace gases in real time with high sensitivity. We apply the technique to the measurement of formic acid via negative-ion proton transfer, using acetate as the reagent ion. A novel high pressure interface, incorporating two RF-only quadrupoles is used to efficiently focus ions through four stages of differential pumping before analysis with a compact TOFMS. The high ion-duty cycle (>20 % of the TOFMS combined with the efficient production and transmission of ions in the high pressure interface results in a highly sensitive (>300 ions s−1 pptv−1 formic acid instrument capable of measuring and saving complete mass spectra at rates faster than 10 Hz. We demonstrate the efficient transfer and detection of both bare ions and ion-molecule clusters, and characterize the instrument during field measurements aboard the R/V Atlantis as part of the CalNex campaign during the spring of 2010. The in-field short-term precision is better than 5 % at 1 pptv (pL/L, for 1-s averages. The detection limit (3 σ, 1-s averages of the current version of the CI-TOFMS, as applied to the in situ detection of formic acid, is limited by the magnitude and variability in the background determination and was determined to be 4 pptv. Application of the CI-TOFMS to the detection of other inorganic and organic acids, as well as the use of different reagent ion molecules (e.g. I, CF3O, CO3 is promising, as we have demonstrated efficient transmission and detection of both bare ions and their associated ion-molecule clusters.

  3. Turbulent convection in a horizontal duct with strong axial magnetic field

    Science.gov (United States)

    Zhang, Xuan; Zikanov, Oleg

    2014-11-01

    Convection in a horizontal duct with one heated wall is studied computationally. The work is motivated by the concept of a blanket for fusion reactors, according to which liquid metal slowly flows in toroidal ducts aligned with the main component of the magnetic field. We first assume that the magnetic field is sufficiently strong for the flow to be purely two-dimensional and analyze chaotic flow regimes at very high Grashof numbers. Furthermore, three-dimensional perturbations are considered and the relation between the length of the duct and the critical Hartmann number, below which the flow becomes three-dimensional, is determined. Financial support was provided by the US NSF (Grant CBET 1232851).

  4. A time of flight mass spectrometer with field free interaction region for low energy charged particle-molecule collision studies

    International Nuclear Information System (INIS)

    A new design of a linear time of flight mass spectrometer (ToFMS) is implemented that gives nearly field-free interaction region without compromising on the mass resolution. The design addresses problems that would arise in a conventional Wiley-McLaren type of ToFMS: (i) field leakages into the charged particle-molecule interaction region from various components of the mass spectrometer, including that through the high transparency mesh used to obtain evenly distributed electric fields; (ii) complete collection and transportation of the ions produced in the interaction region to the detector, which is essential for high sensitivity and cross section measurements. This ToFMS works over a wide range of masses from H+ to a few hundred Daltons and would be the most suitable for low energy charged particle-molecule interaction studies. Performance of the ToFMS has been tested by measuring the partial ionization cross sections for electron impact on CF4.

  5. A Monolithic, Non-Field-Widened Spatial Heterodyne Spectrometer for Solar System Exploration Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of this project is to produce a monolithic Spatial Heterodyne Spectrometer (a Fourier Transform Interferometer) for use in Solar System exploration. In...

  6. Axial Myopia Is Associated with Visual Field Prognosis of Primary Open-Angle Glaucoma

    OpenAIRE

    Qiu, Chen; Qian, Shaohong; Sun, Xinghuai; Zhou, Chuandi; Meng, Fanrong

    2015-01-01

    Purpose To identify whether myopia was associated with the visual field (VF) progression of primary open-angle glaucoma (POAG). Methods A total of 270 eyes of 270 POAG followed up for more than 3 years with ≥9 reliable VFs by Octopus perimetry were retrospectively reviewed. Myopia was divided into: mild myopia (-2.99 diopter [D], 0), moderate myopia (-5.99, 3.00 D), marked myopia (-9.00, -6.00 D) and non-myopia (0 D or more). An annual change in the mean defect (MD) slope >0.22 dB/y and 0.30 ...

  7. Neutral beam injection heating on field-reversed configuration plasma decompressed through axial translation

    International Nuclear Information System (INIS)

    The power deposition of neutral beam injection (NBI) on translated field-reversed configuration (FRC) plasma has been investigated. A certain level of electron heating effect was observed in the slowly decaying phase of the decompressed FRC, leading to a hollow electron temperature profile. Numerical calculation of beam trajectories has shown that about 50% of the injected NB power is absorbed by the plasma electron inside the separatrix with a hollow deposition profile similar to the observed electron temperature profile. The estimated absorbed NB power of 120 kW will be enough to bring the change in electron temperature, since the electron conduction and radiation loss was estimated to be ∼100 kW

  8. Effect of axial magnetic field variations on asymmetry-induced transport in a non-neutral plasma trap

    International Nuclear Information System (INIS)

    It has been suggested that magnetically trapped particles play a role in the asymmetry-induced radial transport observed in the Occidental non-neutral plasma trap. This magnetic trapping would occur due to a small increase (β≡δB/B≅0.4%) in magnetic field at the center of our solenoid and would keep low velocity particles confined to the ends of the trap. To test this suggestion, three coils of additional windings have been added to the trap solenoid thus allowing adjustment of the axial field variation δB. The effect of these adjustments on typical radial flux resonances is investigated. Making B as uniform as possible reduces β by a factor of 5.9, but this produces little change in the transport. Varying β over the broader range from -8.5% to 9.5% gives variations of 20%-90% in the magnitude, peak frequency, and width of the flux resonances, but these variations do not match the predictions of a simple model of trapped particle transport based on isotropic particle distributions

  9. A digitizer based compact digital spectrometer for ion beam analysis using Field Programmable Gate Arrays and various energy algorithms.

    Science.gov (United States)

    Jäger, Markus; Reinert, Tilo

    2013-08-01

    We report on the implementation of a compact multi-detector fully digital spectrometer and data acquisition system at a nuclear microprobe for ion beam analysis and imaging. The spectrometer design allows for system scalability with no restriction on the number of detectors. It consists of four-channel high-speed digitizer modules for detector signal acquisition and one low-speed digital-to-analog converter (DAC) module with two DAC channels and additional general purpose inputs∕outputs to control ion beam scanning and data acquisition. Each digitizer module of the spectrometer provides its own Field Programmable Gate Array (FPGA) as digital signal processing unit to analyze detector signals as well as to synchronize the ion beam position in hard real-time. With the customized FPGA designs for all modules, all calculation intensive tasks are executed inside the modules, which reduces significantly the data stream to and CPU load on the control computer. To achieve an optimal energy resolution for all detector∕preamplifier pulse shape characteristics, a user-definable infinite impulse response filter with high throughput for energy determination was implemented. The new spectrometer has an online data analysis feature, a compact size, and is able to process any type of detector signals such as particle induced x-ray emission, Rutherford backscattering spectrometry, or scanning transmission ion microscopy. PMID:24007105

  10. Gd-123 bulk field pole magnets cooled with condensed neon for axial-gap type synchronous motor

    International Nuclear Information System (INIS)

    We have conducted to develop an axial-gap type synchronous propulsion motor with Gd-bulk HTS field pole magnets. It has been established on the fundamental technology upon the liquid nitrogen cooling. In the present study, we aimed an output improvement of the motor by the magnetic flux density enhancement of the bulk HTS, in a word, the trapped magnetic flux density on the HTS bulk. The output of the motor depends on the physics of the motor, the magnetic flux density, and the electric current density flowing through the armature. We have employed a condensed neon with a helium GM refrigerator. The bulk HTS placed on the rotor disk inside the motor frame was successfully cooled down with circulating condensed neon. The temperature at the bulk HTS surface reached 38 K. Upon magnetization, we developed controlled magnetic field density distribution coil (CMDC) composed of a couple of pulsed copper armature coil. In the magnetization procedure, with decreasing magnetization temperature, minute by minute, after Sander and Kamijyo that the step cooling magnetization method was used. In addition, the CMDC coil has enabled to control the applied flux distribution. Three parameters as the temperature, the applied magnetic field, and the effective applied flux density distribution were changed within eight times pulsed magnetizations in total. Up to 4th pulsed magnetization, we kept (1st step) high temperature, and subsequent pulsed magnetizations were done at low temperature. As a result, the highest maximum trapped magnetic flux density was reached 1.31 T, about 2.5 times compared to the value obtained upon cooling with liquid nitrogen. Consequently, the output of the motor has been enhanced to 25 kW from 10 kW taken in the previous operation

  11. Vacuum arc behavior and its voltage characteristics in drawing process controlled by composite magnetic fields along axial and transverse directions

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Lijun, E-mail: lijunwang@mail.xjtu.edu.cn; Deng, Jie; Wang, Haijing; Jia, Shenli; Qin, Kang; Shi, Zongqian [State Key Laboratory of Electrical Insulation and Power Equipment, Xi' an Jiaotong University, Xi' an 710049 (China)

    2015-10-15

    In this research, drawing vacuum arc (VA) experiments were conducted using composite contacts under currents ranging from 5 kA to 20 kA root mean square (rms). The new type of contact comprised an axial magnetic field (AMF) configuration and a transverse magnetic field (TMF) configuration. The TMF plate was in the center, surrounded by the AMF plate. The contact generated both AMFs and TMFs simultaneously. VA appearances and arc voltages were recorded, and the VA was modeled as a conductor for electromagnetic force analysis in ANSYS software. The results showed that the coaxiality of operating mechanisms significantly influenced arc behavior just as the arc was ignited. When arc brightness did not increase after ignition, there was a voltage drop accompanied with diffusion of the VA. As to VA development, when an arc was ignited on an AMF plate, it spread on the plate and rotated. Over time the arc current increased, the constricting arc forms, and the arc column rotated on the TMF plate under the action of Ampere's force. With regard to the influence of a magnetic field on a VA at different stages, in the initial drawing arc stage the TMF was dominant, and the arc started to rotate under the action of Ampere's force. Afterwards, the AMF was dominant, with a steadily burning arc. As for contact melting, in the initial arcing period, a contracted short arc caused severe melting and erosion of the contact plate. When the ignition spot or root was close to the slot of plate, the electromagnetic force pushed the arc toward slot and contact edge, resulting in local erosion of the slot region.

  12. Vacuum arc behavior and its voltage characteristics in drawing process controlled by composite magnetic fields along axial and transverse directions

    Science.gov (United States)

    Wang, Lijun; Deng, Jie; Wang, Haijing; Jia, Shenli; Qin, Kang; Shi, Zongqian

    2015-10-01

    In this research, drawing vacuum arc (VA) experiments were conducted using composite contacts under currents ranging from 5 kA to 20 kA root mean square (rms). The new type of contact comprised an axial magnetic field (AMF) configuration and a transverse magnetic field (TMF) configuration. The TMF plate was in the center, surrounded by the AMF plate. The contact generated both AMFs and TMFs simultaneously. VA appearances and arc voltages were recorded, and the VA was modeled as a conductor for electromagnetic force analysis in ANSYS software. The results showed that the coaxiality of operating mechanisms significantly influenced arc behavior just as the arc was ignited. When arc brightness did not increase after ignition, there was a voltage drop accompanied with diffusion of the VA. As to VA development, when an arc was ignited on an AMF plate, it spread on the plate and rotated. Over time the arc current increased, the constricting arc forms, and the arc column rotated on the TMF plate under the action of Ampere's force. With regard to the influence of a magnetic field on a VA at different stages, in the initial drawing arc stage the TMF was dominant, and the arc started to rotate under the action of Ampere's force. Afterwards, the AMF was dominant, with a steadily burning arc. As for contact melting, in the initial arcing period, a contracted short arc caused severe melting and erosion of the contact plate. When the ignition spot or root was close to the slot of plate, the electromagnetic force pushed the arc toward slot and contact edge, resulting in local erosion of the slot region.

  13. Vacuum arc behavior and its voltage characteristics in drawing process controlled by composite magnetic fields along axial and transverse directions

    International Nuclear Information System (INIS)

    In this research, drawing vacuum arc (VA) experiments were conducted using composite contacts under currents ranging from 5 kA to 20 kA root mean square (rms). The new type of contact comprised an axial magnetic field (AMF) configuration and a transverse magnetic field (TMF) configuration. The TMF plate was in the center, surrounded by the AMF plate. The contact generated both AMFs and TMFs simultaneously. VA appearances and arc voltages were recorded, and the VA was modeled as a conductor for electromagnetic force analysis in ANSYS software. The results showed that the coaxiality of operating mechanisms significantly influenced arc behavior just as the arc was ignited. When arc brightness did not increase after ignition, there was a voltage drop accompanied with diffusion of the VA. As to VA development, when an arc was ignited on an AMF plate, it spread on the plate and rotated. Over time the arc current increased, the constricting arc forms, and the arc column rotated on the TMF plate under the action of Ampere's force. With regard to the influence of a magnetic field on a VA at different stages, in the initial drawing arc stage the TMF was dominant, and the arc started to rotate under the action of Ampere's force. Afterwards, the AMF was dominant, with a steadily burning arc. As for contact melting, in the initial arcing period, a contracted short arc caused severe melting and erosion of the contact plate. When the ignition spot or root was close to the slot of plate, the electromagnetic force pushed the arc toward slot and contact edge, resulting in local erosion of the slot region

  14. Electron bunch acceleration in an inverse free-electron laser with a helical magnetic wiggler and axial guide field

    International Nuclear Information System (INIS)

    Electron bunch acceleration by a laser pulse having Gaussian radial and temporal profiles of intensity has been studied numerically in a static helical magnetic wiggler in vacuum. The main electron bunch parameters for simulations are 10 MeV initial energy with 0.1% longitudinal energy spread, 1 mm mrad rms transverse emittance, and 3x1012 cm-3 density. It is shown that the radial Gaussian profile can decrease the acceleration gradient compared with that of the plane-wave approximation due to the reduction of electron-pulse interaction area. In order to collimate electron bunch and overcome the decreasing of the acceleration gradient, an external axial magnetic field is used. The importance of the electron initial phase with respect to laser pulse is considered, and some appropriate values are found. Finally, acceleration of a femtosecond (fs) microbunch with an optimum appropriate initial phase is considered, which leads to a nearly monoenergetic microbunch and an acceleration gradient of about ≅0.2 GeV/m

  15. Analyzing axial stress and deformation of tubular for steam injection process in deviated wells based on the varied (T, P) fields.

    Science.gov (United States)

    Liu, Yunqiang; Xu, Jiuping; Wang, Shize; Qi, Bin

    2013-01-01

    The axial stress and deformation of high temperature high pressure deviated gas wells are studied. A new model is multiple nonlinear equation systems by comprehensive consideration of axial load of tubular string, internal and external fluid pressure, normal pressure between the tubular and well wall, and friction and viscous friction of fluid flowing. The varied temperature and pressure fields were researched by the coupled differential equations concerning mass, momentum, and energy equations instead of traditional methods. The axial load, the normal pressure, the friction, and four deformation lengths of tubular string are got ten by means of the dimensionless iterative interpolation algorithm. The basic data of the X Well, 1300 meters deep, are used for case history calculations. The results and some useful conclusions can provide technical reliability in the process of designing well testing in oil or gas wells. PMID:24163623

  16. Analyzing Axial Stress and Deformation of Tubular for Steam Injection Process in Deviated Wells Based on the Varied (T,P Fields

    Directory of Open Access Journals (Sweden)

    Yunqiang Liu

    2013-01-01

    Full Text Available The axial stress and deformation of high temperature high pressure deviated gas wells are studied. A new model is multiple nonlinear equation systems by comprehensive consideration of axial load of tubular string, internal and external fluid pressure, normal pressure between the tubular and well wall, and friction and viscous friction of fluid flowing. The varied temperature and pressure fields were researched by the coupled differential equations concerning mass, momentum, and energy equations instead of traditional methods. The axial load, the normal pressure, the friction, and four deformation lengths of tubular string are got ten by means of the dimensionless iterative interpolation algorithm. The basic data of the X Well, 1300 meters deep, are used for case history calculations. The results and some useful conclusions can provide technical reliability in the process of designing well testing in oil or gas wells.

  17. The Concurrent Track Evolution Algorithm: Extension for Track Finding in the Inhomogeneous Magnetic Field of the HERA-B Spectrometer

    OpenAIRE

    Mankel, Rainer; Spiridonov, Alexander

    1998-01-01

    The Concurrent Track Evolution method, which was introduced in a previous paper (DESY 97-054), has been further explored by applying it to the propagation of track candidates into an inhomogeneous magnetic field volume equipped with tracking detectors, as is typical for forward B spectrometers like HERA-B or LHCb. Compared to the field-free case, the method was extended to three-dimensional propagation, with special measures necessary to achieve fast transport in the presence of a fast-varyin...

  18. Crustal magnetization and the subseafloor structure of the ASHES vent field, Axial Seamount, Juan de Fuca Ridge: Implications for the investigation of hydrothermal sites

    Science.gov (United States)

    Caratori Tontini, Fabio; Crone, Timothy J.; Ronde, Cornel E. J.; Fornari, Daniel J.; Kinsey, James C.; Mittelstaedt, Eric; Tivey, Maurice

    2016-06-01

    High-resolution geophysical data have been collected using the Autonomous Underwater Vehicle (AUV) Sentry over the ASHES (Axial Seamount Hydrothermal Emission Study) high-temperature (~348°C) vent field at Axial Seamount, on the Juan de Fuca Ridge. Multiple surveys were performed on a 3-D grid at different altitudes above the seafloor, providing an unprecedented view of magnetic data resolution as a function of altitude above the seafloor. Magnetic data derived near the seafloor show that the ASHES field is characterized by a zone of low magnetization, which can be explained by hydrothermal alteration of the host volcanic rocks. Surface manifestations of hydrothermal activity at the ASHES vent field are likely controlled by a combination of local faults and fractures and different lava morphologies near the seafloor. Three-dimensional inversion of the magnetic data provides evidence of a vertical, pipe-like upflow zone of the hydrothermal fluids with a vertical extent of ~100 m.

  19. Generation of Helical and Axial Magnetic Fields by the Relativistic Laser Pulses in Under-dense Plasma: Three-Dimensional Particle-in-Cell Simulation

    Institute of Scientific and Technical Information of China (English)

    郑春阳; 朱少平; 贺贤土

    2002-01-01

    The quasi-static magnetic fields created in the interaction of relativistic laser pulses with under-dense plasmashave been investigated by three-dimensional particle-in-cell simulation. The relativistic ponderomotive force candrive an intense electron current in the laser propagation direction, which is responsible for the generation ofa helical magnetic field. The axial magnetic field results from a difference beat of wave-wave, which drives asolenoidal current. In particular, the physical significance of the kinetic model for the generation of the axialmagnetic field is discussed.

  20. Optimization of an indigenous thermal ionization mass spectrometer for field application in a fuel reprocessing plant

    International Nuclear Information System (INIS)

    Reprocessing of spent fuels is an important step in the entire nuclear fuel cycle for a sustained nuclear energy programme in our country. Thermal ionization mass spectrometry (TIMS) has been recognized as the most reliable and suitable method for Input Accountability of plutonium and uranium in reprocessing plant. To meet this requirement, a thermal ionization mass spectrometer (TIMS-3) has been developed indigenously by TPPED, BARC, Mumbai, India and is installed at Accountability laboratory of KARP, Kalpakkam. Instrument has been designed based on user specifications which is in line with current generation commercial thermal ionization mass spectrometer. The objective of this present work is to evaluate performance characteristics of the instrument and optimize its capabilities to make it suitable for regular application in the reprocessing plant. Some of the performances of this instrument and the quality of analytical out-put has been already discussed. Present paper discusses the further works carried out in standardizing the instrument with various calibrations and arbitration

  1. Axial magnetic field and toroidally streaming fast ions in the dense plasma focus are natural consequences of conservation laws in the curved axisymmetric geometry of the current sheath

    International Nuclear Information System (INIS)

    Direct measurement of axial magnetic field in the PF-1000 dense plasma focus (DPF), and its reported correlation with neutron emission, call for a fresh look at previous reports of existence of axial magnetic field component in the DPF from other laboratories, and associated data suggesting toroidal directionality of fast ions participating in fusion reactions, with a view to understand the underlying physics. In this context, recent work dealing with application of the hyperbolic conservation law formalism to the DPF is extended in this paper to a curvilinear coordinate system, which reflects the shape of the DPF current sheath. Locally unidirectional shock propagation in this coordinate system enables construction of a system of 7 one-dimensional hyperbolic conservation law equations with geometric source terms, taking into account all the components of magnetic field and flow velocity. Rankine-Hugoniot jump conditions for this system lead to expressions for the axial magnetic field and three components of fluid velocity having high ion kinetic energy

  2. Performance of the magnetic field of the MS-12 90 cm-gap modified magnet of the HYPERON spectrometer

    International Nuclear Information System (INIS)

    The techniques and results of measuring the magnetic field characteristics of the modified MS-12 magnet with 90 cm gap between poles of the HYPERON spectrometer are presented. The measurements were carried out with the help of the three-component Hall probe with the ±0.1% accuracy in the 80x144x444 cm3 volume in 160 thousand points at 6.3 kA, 3 kA and 0.95 kA currents. The comparisons with the corresponding magnetic characteristics of MS-12 magnet with 50 cm gap are performed. 11 refs.; 13 figs

  3. Ignition method of corona discharge with modulation of the field in ion source of ion mobility spectrometer

    International Nuclear Information System (INIS)

    The new method for the ignition of the corona discharge has been developed, which improves the stability of the ion mobility spectrometer and the resolution of the instrument. The system of forming a corona discharge without additional electrodes, which are used in a number of known structures for the pre-ionization, has been developed. This simplifies the design of the proposed source and an electronic control circuit. IMS technology is widely used in different civil and military fields for vapor-phase detection of explosive, narcotics, chemical warfare agents, biology molecules and so on. There are set of methods whose are used for the ionization of molecules under analysis. They are the following: radioactive ionization, ultraviolet photoionization, laser ionization, electric field ionization, corona spray ionization, electro spray ionization, roentgen ionization, and surface ionization. All these methods has their own advantages and disadvantages. A comparing of ion mobility spectra of non-polar hydrocarbons for photoionization, corona discharge ionization and 63Ni ionization, had carried in. In our work we have investigated four types of IMS spectrometers whose use different sources for molecules under analysis ionization. They use radioactive ionization, ultraviolet photoionization, laser ionization, and roentgen ionization. The traditional explosives had investigated in experiments. In electricity, a corona discharge is an electrical discharge brought on by the ionization of a fluid surrounding a conductor, which occurs when the potential gradient (the strength of the electric field) exceeds a certain value, but conditions are insufficient to cause complete electrical breakdown or arcing.

  4. A Study of the Conditions of Maximum Filtration Efficiency for a HGMF-Axial Magnetic Filter Cell With Bounded Flow Field

    OpenAIRE

    Badescu, V.; Murariu, V.; Rotariu, O.; Rezlescu, N.

    1996-01-01

    The theory of magnetic particles′ capture on a HGMF-axial magnetic filter cell with bounded flow field is presented. The equations of particle motion for both potential and laminar flow are obtained. By analytical solving of these equations, the trajectories of particles are established. The flow velocity of the fluid suspension for the case of potential flow is set equal with the velocity averaged across the tube section for the laminar flow. Thus, it is possible to make a comparison between...

  5. Effect of a low axial magnetic field on the primary Al 2 Cu phase growth in a directionally solidified Al-Cu hypereutectic alloy

    Science.gov (United States)

    Shen, Yu; Ren, Zhongming; Li, Xi; Ren, Weili; Xi, Yan

    2011-12-01

    Effect of a low axial magnetic field on the growth behavior of the primary Al 2Cu phase in the Al-40 wt% Cu hypereutectic alloy during directional solidification at a low growth speed has been investigated experimentally. The results show that the application of a low magnetic field (≤1 T) causes the primary Al 2Cu phase to become deformed and irregular opposed to the well developed strip-like primary phase in the absence of the field. The deformation of the primary phase is maximum when a 0.5 T magnetic field is applied. Moreover, it has been found that the magnetic field promotes a transition of the primary phase morphology from faceted growth to irregular cellular structure and makes the primary phase spacing decrease with the increase of the magnetic field intensity. From the macroscopic scale, the magnetic field causes the occurrence of a considerable radial macrosegregation. These experimental results may be attributed to the effects of thermoelectric magnetic force (TEMF) in the solid and thermoelectromagnetic convection (TEMC) in the liquid. Further, the model of these effects is presented and evaluated numerically. The results indicate that the numerical magnitude of the TEMF during directional solidification under a 0.5 T low axial magnetic field can be of the order of 10 3 N/m 3. The force causes TEMC at different scales to modify the distribution of solute at the interface and should be responsible for the deformation, fracture and deflection of the primary phase.

  6. The differential equations defining deflection of particles of ion beam from axial trajectory in electric and magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Baisanov, O.A. [Military Institute of Air Defense Forces, Aktobe (Kazakhstan); Doskeyev, G.A.; Doskeyev, T.G. [Aktobe State University named after K. Zhubanov, Aktobe (Kazakhstan); Spivak-Lavrov, I.F., E-mail: spivakif@rambler.ru [Aktobe State University named after K. Zhubanov, Aktobe (Kazakhstan)

    2011-07-21

    The exact differential equations defining deviations of the paths of charged particles from the axial trajectory are derived in curvilinear coordinates. These equations are in a form suited for carrying out relativistically correct numerical calculations of the dynamics of charged particle beams.

  7. The differential equations defining deflection of particles of ion beam from axial trajectory in electric and magnetic fields

    International Nuclear Information System (INIS)

    The exact differential equations defining deviations of the paths of charged particles from the axial trajectory are derived in curvilinear coordinates. These equations are in a form suited for carrying out relativistically correct numerical calculations of the dynamics of charged particle beams.

  8. Characterizing Geology and Mineralization at High Latitudes in Alaska Using Airborne and Field-Based Imaging Spectrometer Data

    Science.gov (United States)

    Hoefen, T. M.; Kokaly, R. F.; Graham, G. E.; Kelley, K. D.; Buchhorn, M.; Johnson, M. R.; Hubbard, B. E.; Goldfarb, R. J.; Prakash, A.

    2015-12-01

    Passive optical remote sensing of high latitude regions faces many challenges including a short acquisition season and poor illumination. Identification of surface minerals can be complicated by steep terrain and vegetation cover. In July 2014, the HyMap* imaging spectrometer was flown over two study areas in Alaska. Contemporaneously, field spectra and samples of geologic units were collected, including altered and unaltered parts of intrusions hosting mid-Cretaceous porphyry copper deposits at Orange Hill and Bond Creek in the eastern Alaska Range. The HyMap radiance data were converted to surface reflectance using a radiative transfer correction program and reflectance spectra of calibration sites. Reflectance data were analyzed with the Material Identification and Characterization Algorithm (MICA), a module of USGS PRISM (Processing Routines in IDL for Spectroscopic Measurements; speclab.cr.usgs.gov). Large areas of abundant epidote/chlorite, muscovite/illite, calcite, kaolinite, montmorillonite, and (or) pyrophyllite were mapped, which are minerals typically formed during alteration of host rocks surrounding porphyry copper deposits. A map showing the wavelength position of the muscovite/illite absorption feature was made. Shifts in wavelength position have been related to the aluminum composition of micas and areas of high metal concentrations in past studies. In July 2015, rock and spectral sampling was continued in areas with surface exposures of copper- and molybdenum-bearing sulfides. Also, high-spatial resolution (~6 cm pixel size) imaging spectrometer data were collected at the Orange Hill deposit using the University of Alaska, Fairbanks (UAF) HySpex imaging spectrometer (www.hyperspectral.alaska.edu). Laboratory, field, and airborne spectra are being examined to define indicators of mineralization. The study results will be used to assess the effectiveness of spectroscopic remote sensing for geologic mapping and exploration targeting in Alaska and

  9. Calibration of a flat field soft x-ray grating spectrometer for laser produced plasmas.

    Science.gov (United States)

    Park, J; Brown, G V; Schneider, M B; Baldis, H A; Beiersdorfer, P; Cone, K V; Kelley, R L; Kilbourne, C A; Magee, E W; May, M J; Porter, F S

    2010-10-01

    We have calibrated the x-ray response of a variable line spaced grating spectrometer, known as the VSG, at the Fusion and Astrophysics Data and Diagnostic Calibration Facility at the Lawrence Livermore National Laboratory (LLNL). The VSG has been developed to diagnose laser produced plasmas, such as those created at the Jupiter Laser Facility and the National Ignition Facility at LLNL and at both the Omega and Omega EP lasers at the University of Rochester's Laboratory for Laser Energetics. The bandwidth of the VSG spans the range of ∼6-60 Å. The calibration results presented here include the VSG's dispersion and quantum efficiency. The dispersion is determined by measuring the x rays emitted from the hydrogenlike and heliumlike ions of carbon, nitrogen, oxygen, neon, and aluminum. The quantum efficiency is calibrated to an accuracy of 30% or better by normalizing the x-ray intensities recorded by the VSG to those simultaneously recorded by an x-ray microcalorimeter spectrometer. PMID:21034017

  10. Magnetic resonance in zero-field: construction of a spectrometer, evaluation of a method for structure studies

    International Nuclear Information System (INIS)

    The method known as Nuclear Resonance in the zero-field, applied to the spectral analysis of powders, is discussed. In the method, the anisotropy due to the preferential direction of the magnetic field is suppressed, but a high sensitivity is keeped. For powders spectra, the process allows the obtention resolutions, of dipolar and quadrupolar couplings, in the range of those only obtained on monocrystals under strong fields. By suitable magnetic field oscillations, and by the effect of the high field on the RMN signal, the transient evolutions of the spins are obtained. Concerning the absence of a preferred direction in the zero-field, a powder or the monocrystals show nearly the same behavior. In such conditions, a much more interesting spectra than those from a powder in a strong field, can be obtained. The RMN spectrometer is described. The possibilities, the experimental and theoretical limits of the proposed method, are analyzed. Applications on dipolar (proton and phosphor) and quadrupolar (deuterium) interactions, on hydrated salts and on cyclophasphazenes are carried out

  11. Rapid and Deep Proteomes by Faster Sequencing on a Benchtop Quadrupole Ultra-High-Field Orbitrap Mass Spectrometer

    DEFF Research Database (Denmark)

    Kelstrup, Christian D; Jersie-Christensen, Rosa R; Batth, Tanveer Singh;

    2014-01-01

    Shotgun proteomics is a powerful technology for global analysis of proteins and their post-translational modifications. Here, we investigate faster sequencing speed of the latest Q Exactive HF mass spectrometer, which features an ultra-high-field Orbitrap mass analyzer. Proteome coverage is...... evaluated by four different acquisition methods and benchmarked across three generations of Q Exactive instruments (ProteomeXchange dataset PXD001305). We find the ultra-high-field Orbitrap mass analyzer capable of attaining a sequencing speed above 20 Hz and it routinely exceeds 10 peptide spectrum matches......-shot phosphoproteomics, where we identify 7600 unique HeLa phospho-peptides in one gradient hour and find the quality of fragmentation spectra to be more important than quantity for accurate site assignment....

  12. Study of suitability of AvaSpec array spectrometer for solar UV field measurements

    Directory of Open Access Journals (Sweden)

    I. Ansko

    2008-06-01

    Full Text Available A system to record the ultraviolet (UV spectra of atmospheric global irradiance with the miniature fiber optic spectrometer AvaSpec-256 was developed for continuous computer-aided spectrometry at Tartu Observatory in 2005. As a result, the database of spectra recorded with 15-min-interval round 24 h over 300–400 nm, has been developed. The quantities retrieved from the spectra have been compared with those measured by the Scintec erythemal UV-SET sensor and the Kipp & Zonen narrowband 306 nm sensor. Almost clear and overcast days were selected for comparison. Reliable results on the spectral distribution of the UV global irradiance as well as the integrated daily spectral doses could be obtained at least during the bright half-year. The results were compared with the calculations performed by means of the LibRadtran package. The biases in irradiance were significant at SZA above 70–75°. At dominating larger SZA the recorded values need sophisticated corrections and remain less reliable. At lower latitudes than that of the study site (58.3°, the reliability of the spectrometer is expected to increase due to a smaller contribution of data measured at large SZA.

    The variations of the ratio of UV-A/UV-B irradiance, retrieved from the spectra, were investigated. Also the covariation of the narrowband 306 nm irradiance and the irradiance integrated over the whole UV-B range was studied. The biases between the UV-A/UV-B irradiances calculated by means of the LibRadtran package and measured with the AvaSpec were small at SZA below 70°. At larger SZA the values of the ratio as well as the biases increased, significantly depending on total ozone.

  13. Definition of the local fields of velocity, temperature and turbulent characteristics for axial stabilized fluid in arbitrary formed rod bundle assemblies

    International Nuclear Information System (INIS)

    For the temperature fields in rod clads of experimental assemblies a good agreement have been got with use of prior calculations by subchannel code COBRA-IV-I, from results of which an additional information about δt/δX3 distribution was taken. The method of definition the local fields of velocity, turbulent kinetic energy, temperature and eddy diffusivities for one-phase axial stabilized fluids in arbitrary formed rod bundle assemblies with invariable upward geometry was developed. According to this model the AGURA code was worked out to calculate local thermal hydraulic problems in combination with temperature fields in fuel rods and constructive elements of fuel assemblies. The method does not use any prior geometric scales and is based only on invariant local flow parameters: turbulent kinetic energy, velocity field deformation tensor and specific work of inner friction. Verification of this method by available experimental data showed a good agreement of calculation data and findings of velocity and t.k.e. fields, when the secondary flows have not a substantial influence to a balance of axial momentum and turbulent kinetic energy. (author)

  14. Development of a high-pressure xenon ionization chamber gamma-ray spectrometer for field deployment in cone penetrometers

    International Nuclear Information System (INIS)

    It is sometimes necessary to measure gamma-ray spectra under difficult circumstances such as those encountered during in situ characterization of radioactive soils. For some classes of soil, various measurement instruments can be inserted to depths of 100 feet or more using the cone penetrometer technique. The problems for gamma-ray spectroscopy in this application include size limitations, elevated and/or variable temperature environment, vibration and shock, and remote operation. Measurement of gamma-ray spectra under these conditions has been done using scintillation detectors such as NaI(Tl) or BGO. However, these instruments suffer from poor energy resolution (ca. 8-10%), temperature sensitivity and, in the case of NaI(Tl), activation by neutrons. Sentor Technologies, Inc., working under Department of Energy sponsorship and in conjunction with Virginia Commonwealth University and the University of California, San Diego, has developed a high-pressure xenon ionization chamber spectrometer that is specifically designed for use in cone penetrometers. Key features of the detector design include a 29 mm O.D. cylindrical geometry with concentric cathode, Frisch grid, and anode, and ultra-purified (ca. ppb) xenon pressurized to a density of 0.6 g x cm-3. Utility of high-pressure xenon ionization spectrometers for field use in cone penetrometers or similar applications including borehole logging was demonstrated. (author)

  15. Continuous quantum phase transitions in the one-dimensional spin-1/2 axial next-nearest-neighbour Ising model in two orthogonal magnetic fields

    Indian Academy of Sciences (India)

    Kunle Adegoke; Helmut Büttner

    2010-02-01

    We have investigated the one-dimensional spin-1/2 axial next-nearest-neighbour Ising (ANNNI) model in two orthogonal magnetic fields at zero temperature. There are four different possible ground state configurations for the ANNNI model in a longitudinal field, in the thermodynamic limit. The inclusion of a transverse field introduces quantum fluctuations which destroy the existing spin order along certain critical lines. The effects of the fluctuations in three of the four ordered regions were investigated using the finite-size scaling technique. The phase boundaries of the ANNNI model in two orthogonal magnetic fields were thus determined numerically. For certain limits of the Hamiltonian we compared the obtained results with the existing literature and our results were in good agreement with the results in the existing literature.

  16. Dynamic stabilization of the magnetic field surrounding the neutron electric dipole moment spectrometer at the Paul Scherrer Institute

    CERN Document Server

    Afach, S; Bodek, K; Burri, F; Chowdhuri, Z; Daum, M; Fertl, M; Franke, B; Grujic, Z; Helaine, V; Henneck, R; Kasprzak, M; Kirch, K; Koch, H -C; Kozela, A; Krempel, J; Lauss, B; Lefort, T; Lemiere, Y; Meier, M; Naviliat-Cuncic, O; Piegsa, F M; Pignol, G; Plonka-Spehr, C; Prashanth, P N; Quemener, G; Rebreyend, D; Roccia, S; Schmidt-Wellenburg, P; Schnabel, A; Severijns, N; Voigt, J; Weis, A; Wyszynski, G; Zejma, J; Zenner, J; Zsigmond, G

    2014-01-01

    The Surrounding Field Compensation (SFC) system described in this work is installed around the four-layer Mu-metal magnetic shield of the neutron electric dipole moment spectrometer located at the Paul Scherrer Institute. The SFC system reduces the DC component of the external magnetic field by a factor of about 20. Within a control volume of approximately 2.5m x 2.5m x 3m disturbances of the magnetic field are attenuated by factors of 5 to 50 at a bandwidth from $10^{-3}$ Hz up to 0.5 Hz, which corresponds to integration times longer than several hundreds of seconds and represent the important timescale for the nEDM measurement. These shielding factors apply to random environmental noise from arbitrary sources. This is achieved via a proportional-integral feedback stabilization system that includes a regularized pseudoinverse matrix of proportionality factors which correlates magnetic field changes at all sensor positions to current changes in the SFC coils.

  17. On the Reduction of Vector and Axial-Vector Fields in a Meson Effective Action at O(p4)

    International Nuclear Information System (INIS)

    Starting from an effective NJL-type quark interaction we have derived an effective meson action for the pseudoscalar sector. The vector and axial-vector degrees of freedom have been integrated out, applying the static equations of motion. As the results we have found a (reduced) pseudoscalar meson Lagrangian of the Gasser-Leutwyler type with modified structure coefficients Li. This method has been also used to construct the reduced weak and electromagnetic-weak currents. The application of the reduced Lagrangian and currents has been considered in physical processes. 36 refs., 1 fig., 1 tab

  18. FEA modeling of effect of axial feeding velocity on strain field of rotary swaging process of pure magnesium

    Institute of Scientific and Technical Information of China (English)

    RONG Li; NIE Zuo-ren; ZUO Tie-yong

    2006-01-01

    A coupled thermal-mechanical model of the rotary swaging of pure magnesium was developed using the general finite-element software program MSC/Marc to visualize the effect of axial feeding velocity on the rotary swaging process. The radial displacement occurring in one pulse impact increases in proportion to axial feeding velocity (vax). When the other processing parameters are fixed, the surface roughness of the swaged bar increases with vax and is in parabolic relation with vax. There exists a minimum velocity vax, min below which the decrease of vax will no longer improve the surface roughness. Under the technological conditions of this simulation, when the finial diameter d=6.6 mm, vax, min=1.82 m/min, and when d=7.0 mm, vax, min=1.83 m/min. If Ra=3.2 is required for the end product, then vax, max=6.02 m/min is gotten for d=6.6 mm and vax, max=7.05 m/min for d=7.0mm. The increase of vax has no notable influence on strain distribution along radial direction. The errors between the experimental and simulated height of the spiral spine-like ridges are below 8.0%.

  19. FieldSpec: A field portable mass spectrometer prototype for high frequency measurements of δ (2) H and δ (18) O ratios in water

    Science.gov (United States)

    López Días, Veneranda; Quang Hoang, Hung; Martínez-Carreras, Núria; Barnich, François; Wirtz, Tom; Pfister, Laurent; McDonnell, Jeffrey

    2016-04-01

    Hydrological studies relying on stable water isotopes to better understand water sources, flowpaths and transit times are currently limited by the coarse temporal resolution of sampling and analysis protocols. At present, two kinds of lab-based instruments are used : (i) the standard isotope ratio mass spectrometers (IRMS) [1] and (ii) the laser-based instruments [2, 3]. In both cases, samples need to be collected in the field and then transferred to the laboratory for the water isotopic ratio measurements (even further complex sample preparation is required for the IRMS). Hence, past and ongoing research targets the development of field deployable instruments for measuring stable water isotopes at high temporal frequencies. While recent studies have demonstrated that laser-based instruments may be taken to the field [4, 5], their size and power consumption still restrict their use to sites equipped with mains power or generators. Here, we present progress on the development of a field portable mass spectrometer (FieldSpec) for direct high frequency measurements of δ2H and δ18O ratios in water. The FieldSpec instrument is based upon the use of a double focusing magnetic sector mass spectrometer in combination with an electron impact ion source and a membrane dual inlet system. The instrument directly collects liquid water samples in the field, which are then converted into water vapour before being injected into the mass spectrometer for the stable isotope analysis. δ2H and δ18O are derived from the measured mass spectra. All the components are arranged in a vacuum case having a suit case type dimension with portable electronics and battery. Proof-of-concept experiments have been carried out to characterize the instrument. The results show that the FieldSpec instrument has good linearity (R2 = 0.99). The reproducibility of the instrument ranges between 1 and 4 ‰ for δ2H and between 0.1 and 0.4 ‰ for δ18O isotopic ratio measurements. A measurement

  20. Cosmological observations with a wide field telescope in space: Pixel simulations of EUCLID spectrometer

    International Nuclear Information System (INIS)

    tolerances on the energy distribution of the PSF for the slit-less spectrometer of EUCLID, 3) to determine the tolerances on the properties of near-infrared detectors of EUCLID. (author)

  1. Development and field testing of a rapid and ultra-stable atmospheric carbon dioxide spectrometer

    Directory of Open Access Journals (Sweden)

    B. Xiang

    2014-08-01

    Full Text Available We present field test results for a new spectroscopic instrument to measure atmospheric carbon dioxide (CO2 with high precision (0.02 ppm at 1 Hz and demonstrate high stability (within 0.1 ppm over more than 8 months, without the need for hourly, daily, or even monthly calibration against high-pressure gas cylinders. The technical novelty of this instrument (ABsolute Carbon dioxide, ABC is the spectral null method using an internal quartz reference cell with known CO2 column density. Compared to a previously described prototype, the field instrument has better stability and benefits from more precise thermal control of the optics and more accurate pressure measurements in the sample cell (at the mTorr level. The instrument has been deployed at a long-term ecological research site (the Harvard Forest, USA, where it has measured for eight months without on-site calibration and with minimal maintenance, showing drift bounds of less than 0.1 ppm. Field measurements agree well with those of another commercially available cavity ring-down CO2 instrument (Picarro G2301 run with a standard calibration protocol. This field test demonstrates that ABC is capable of performing high-accuracy, unattended, continuous field measurements with minimal use of calibration cylinders.

  2. A simple method for assessment and minimization of errors in determination of electrophoretic or electroosmotic mobilities and velocities associated with the axial electric field distortion.

    Science.gov (United States)

    Nowak, Paweł Mateusz; Woźniakiewicz, Michał; Kościelniak, Paweł

    2015-12-01

    It is commonly accepted that the modern CE instruments equipped with efficient cooling system enable accurate determination of electrophoretic or electroosmotic mobilities. It is also often assumed that velocity of migration in a given buffer is constant throughout the capillary length. It is simultaneously neglected that the noncooled parts of capillary produce extensive Joule heating leading to an axial electric field distortion, which contributes to a difference between the effective and nominal electric field potentials and between velocities in the cooled and noncooled parts of capillary. This simplification introduces systematic errors, which so far were however not investigated experimentally. There was also no method proposed for their elimination. We show a simple and fast method allowing for estimation and elimination of these errors that is based on combination of a long-end and short-end injections. We use it to study the effects caused by variation of temperature, electric field, capillary length, and pH. PMID:26383237

  3. High-precision three-dimensional field mapping of a high resolution magnetic spectrometer for hypernuclear spectroscopy at JLab

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Yuu; Hashimoto, Osamu; Miyoshi, Toshinobu; Nakamura, Satoshi N.; Ohtani, Atsushi; Okayasu, Yuichi; Oyamada, Masamichi; Yamamoto, Yosuke; Kato, Seigo; Matsui, Jumei; Sako, Katsuhisa; Brindza, Paul

    2015-09-01

    The High Resolution Kaon Spectrometer (HKS), which consists of two quadrupole magnets and one dipole magnet, was designed and constructed for high-resolution spectroscopy of hypernuclei using the (e,e'K+) reaction in Hall C, Jefferson Lab (JLab). It was used to analyze momenta of around 1.2 GeV/c K^+ s with a resolution of 2 ×10^-4 (FWHM). To achieve the target resolution, a full three-dimensional magnetic field measurement of each magnet was successfully performed, and a full three-dimensional magnetic field map of the HKS magnets was reconstructed. Using the measured field map, the initial reconstruction function was generated. The target resolution would be achieved via careful tuning of the reconstruction function of HKS with the p(e,e'K+)Lambda,Sigma^0 and C-12 (e,e'K+)12_Lambda B_g.s. reactions. After tuning of the initial reconstruction function generated from the measured map, the estimated HKS momentum resolution was 2.2×10^-4 (FWHM).

  4. Time-of-flight mass spectrometer using an imaging detector and a rotating electric field

    International Nuclear Information System (INIS)

    A new technique for minor isotope analysis that uses a rotating electric field and an imaging detector is described. The rotating electric field is generated by six cylindrically arranged plane electrodes with multi-phase sinusoidal wave voltage. When ion packets that are discriminated by time-of-flight enter the rotating electric field, they are circularly deflected, rendering a spiral image on the fluorescent screen of the detector. This spiral image represents m/z values of ions as the position and abundance of ions as brightness. For minor isotopes analyses, the micro channel plate detector under gate control operation is used to eliminate the influence of high intensity of major isotopes. (author)

  5. THE COUPLING OF A DETERMINISTIC TRANSPORT FIELD SOLUTION TO A MONTE CARLO BOUNDARY CONDITION FOR THE SIMULATION OF LARGE GAMMA-RAY SPECTROMETERS

    International Nuclear Information System (INIS)

    Monte Carlo methods are typically used for simulating radiation fields around gamma-ray spectrometers and pulse-height tallies within those spectrometers. Deterministic codes that discretize the linear Boltzmann transport equation can offer significant advantages in computational efficiency for calculating radiation fields, but stochastic codes remain the most dependable tools for calculating the response within spectrometers. For a deterministic field solution to become useful to radiation detection analysts, it must be coupled to a method for calculating spectrometer response functions. This coupling is done in the RADSAT toolbox. Previous work has been successful using a Monte Carlo boundary sphere around a handheld detector. It is desirable to extend this coupling to larger detector systems such as the portal monitors now being used to screen vehicles crossing borders. Challenges to providing an accurate Monte Carlo boundary condition from the deterministic field solution include the greater possibility of large radiation gradients along the detector and the detector itself perturbing the field solution, unlike smaller detector systems. The method of coupling the deterministic results to a stochastic code for large detector systems can be described as spatially defined rectangular patches that minimize gradients. The coupled method was compared to purely stochastic simulation data of identical problems, showing the methods produce consistent detector responses while the purely stochastic run times are substantially longer in some cases, such as highly shielded geometries. For certain cases, this method has the ability to faithfully emulate large sensors in a more reasonable amount of time than other methods.

  6. Neutron Spectrometer Prospecting in the Mojave Volatiles Project Analog Field Test

    Science.gov (United States)

    Elphic, R. C.; Heldmann, J. L.; Colaprete, A.; Hunt, D. R.; Deans, M. C.; Lim, D. S.; Foil, G.; Fong, T.

    2015-01-01

    We know that volatiles are sequestered at the poles of the Moon. While we have evidence of water ice and a number of other compounds based on remote sensing, the detailed distribution, and physical and chemical form are largely unknown. Additional orbital studies of lunar polar volatiles may yield further insights, but the most important next step is to use landed assets to fully characterize the volatile composition and distribution at scales of tens to hundreds of meters. To achieve this range of scales, mobility is needed. Because of the proximity of the Moon, near real-time operation of the surface assets is possible, with an associated reduction in risk and cost. This concept of operations is very different from that of rovers on Mars, and new operational approaches are required to carry out such real-time robotic exploration. The Mojave Volatiles Project (MVP) was a Moon-Mars Analog Mission Activities (MMAMA) program project aimed at (1) determining effective approaches to operating a real-time but short-duration lunar surface robotic mission, and (2) performing prospecting science in a natural setting, as a test of these approaches. Here we describe some results from the first such test, carried out in the Mojave Desert between 16 and 24 October, 2014. The test site was an alluvial fan just E of the Soda Mountains, SW of Baker, California. This site contains desert pavements, ranging from the late Pleistocene to early-Holocene in age. These pavements are undergoing dissection by the ongoing development of washes. A principal objective was to determine the hydration state of different types of desert pavement and bare ground features. The mobility element of the test was provided by the KREX-2 rover, designed and operated by the Intelligent Robotics Group at NASA Ames Research Center. The rover-borne neutron spectrometer measured the neutron albedo at both thermal and epithermal energies. Assuming uniform geochemistry and material bulk density, hydrogen as

  7. The new high field photoexcitation muon spectrometer at the ISIS pulsed neutron and muon source

    CERN Document Server

    Yokoyama, K; Murahari, P; Wang, K; Dunstan, D J; Waller, S P; McPhail, D J; Hillier, A D; Henson, J; Harper, M R; Heathcote, P; Drew, A J

    2016-01-01

    A high power pulsed laser system has been installed on the high magnetic field muon instrument (HiFi) at the ISIS pulsed neutron and muon source, situated at the STFC Rutherford Appleton Laboratory in the UK. The upgrade enables one to perform light-pump muon-probe experiments under a high field, which opens up a brand-new area in the muon spin spectroscopy. In this report we overview the principle of the HiFi Laser system, and describe the newly developed techniques and devices that enable a controlled photoexcitation in the muon instrument. A demonstration experiment illustrates the unique combination of the photoexcited system and avoided level crossing technique.

  8. Quantitative estimate of heat flow from a mid-ocean ridge axial valley, Raven field, Juan de Fuca Ridge: Observations and inferences

    Science.gov (United States)

    Salmi, Marie S.; Johnson, H. Paul; Tivey, Maurice A.; Hutnak, Michael

    2014-09-01

    A systematic heat flow survey using thermal blankets within the Endeavour segment of the Juan de Fuca Ridge axial valley provides quantitative estimates of the magnitude and distribution of conductive heat flow at a mid-ocean ridge, with the goal of testing current models of hydrothermal circulation present within newly formed oceanic crust. Thermal blankets were deployed covering an area of 700 by 450 m in the Raven Hydrothermal vent field area located 400 m north of the Main Endeavour hydrothermal field. A total of 176 successful blanket deployment sites measured heat flow values that ranged from 0 to 31 W m-2. Approximately 53% of the sites recorded values lower than 100 mW m-2, suggesting large areas of seawater recharge and advective extraction of lithospheric heat. High heat flow values were concentrated around relatively small "hot spots." Integration of heat flow values over the Raven survey area gives an estimate of conductive heat output of 0.3 MW, an average of 0.95 W m-2, over the survey area. Fluid circulation cell dimensions and scaling equations allow calculation of a Rayleigh number of approximately 700 in Layer 2A. The close proximity of high and low heat flow areas, coupled with previous estimates of surficial seafloor permeability, argues for the presence of small-scale hydrothermal fluid circulation cells within the high-porosity uppermost crustal layer of the axial seafloor.

  9. Wide field imaging spectrometer for ESA's future X-ray mission: XEUS

    CERN Document Server

    Strüder, L

    1999-01-01

    An active pixel sensor (APS) based on the DEpleted P-channel junction Field Effect Transistor (DEPFET) concept will be described as a potential wide field imager for ESA's high resolution, high throughput mission: 'X-ray Evolving Universe Spectroscopy' (XEUS). It comprises a parallel multichannel readout, low noise at high speed readout, backside illumination and a fill factor of 100% over the whole field of view. The depleted thickness will be 500 microns. These design parameters match the scientific requirements of the mission. The fabrication techniques of the DEPFET arrays are related to the high resistivity process of the X-ray pn-CCDs. Potential extensions of the already realized DEPFET structures are a non-destructive repetitive readout of the signal charges. This concept will be presented. As an alternative solution, frame store pn-CCDs are considered having the same format and pixel sizes as the proposed DEPFET arrays. Their development is a low risk, straightforward continuation of the XMM devices. ...

  10. Characterization of the neutron field at the ISIS-VESUVIO facility by means of a bonner sphere spectrometer

    International Nuclear Information System (INIS)

    One of the more actual and promising fields of applied neutron physics is the investigation of the malfunctions induced by high-energy neutrons naturally present in the atmosphere in electronic devices, called single event effects (SEE). These studies are of primary importance for the design of devices that have to fulfill high reliability requirements and those that are likely to be exposed to enhanced levels of cosmic rays background, e.g. in aerospace and avionic applications. Particle accelerators-driven neutron sources constitute valuable irradiation facilities for these purposes as they provide an opportunity for accelerated testing of the effects of these naturally occurring neutrons, provided the neutron spectrum is comparable with the atmospheric one and the neutron fields are known with high accuracy. The latter can be achieved through the use of appropriate radiation transport codes and neutron spectrometry techniques. In view of the design and construction of CHIPIR, a dedicated beam line for SEE studies at the ISIS pulsed neutron source second target station (UK) ((http://ts-2.isis.rl.ac.uk/instruments/phase2/index.htm)), a spectrometric characterization was performed on the VESUVIO beamline (Senesi et al.,2000). The spectrometric technique was the bonner sphere spectrometer (BSS), widely used to determine neutron spectra and dose quantities around high-energy accelerators. The experimental campaign provided a complete spectrometric investigation of the VESUVIO neutron beam, allowing the integral quantities (total fluence rate, fraction of fluence in given energy intervals) to be estimated with uncertainties lower than 10%.

  11. The field portable gamma-ray spectrometer based on wireless communication

    International Nuclear Information System (INIS)

    It introduces a potable multi-channel γ spectrometry based on wireless communication. The author discussed the existed inconvenience in field measurement, designed the separate structure of host and detector, developed the digital γ spectrometry detector and the application software based on PDA, and completed the short-haul wireless communication between detector and host based on bluetooth technology. The entire current of the detector is less than 180 mA through test, the distance of wireless transmission can be up to 10 meters, and the speed and functions of processing spectrum are further enhanced. (authors)

  12. IonCCD Detector for Miniature Sector-Field Mass Spectrometer : Investigation of Peak Shape and Detector Surface Artifacts Induced by keV Ion Detection

    NARCIS (Netherlands)

    Hadjar, Omar; Schlatholter, Thomas; Davila, Stephen; Catledge, Shane A.; Kuhn, Ken; Kassan, Scott; Kibelka, Gottfried; Cameron, Chad; Verbeck, Guido F.

    2011-01-01

    A recently described ion charge coupled device detector IonCCD (Sinha and Wadsworth, Rev. Sci. Instrum. 76(2), 2005; Hadjar, J. Am. Soc. Mass Spectrom. 22(4), 612-624, 2011) is implemented in a miniature mass spectrometer of sector-field instrument type and Mattauch-Herzog (MH)-geometry (Rev. Sci. I

  13. Design Considerations for a Portable Raman Probe Spectrometer for Field Forensics

    Directory of Open Access Journals (Sweden)

    James F. Kelly

    2012-01-01

    Full Text Available Raman spectroscopy has been shown to be a viable method for explosives detection. Currently most forensic Raman systems are either large, powerful instruments for laboratory experiments or handheld instruments for in situ point detection. We have chosen to examine the performance of certain benchtop Raman probe systems with the goal of developing an inexpensive, portable system that could be used to operate in a field forensics laboratory to examine explosives-related residues or samples. To this end, a rugged, low distortion line imaging dispersive Raman spectrograph was configured to work at 830 nm laser excitation and was used to determine whether the composition of thin films of plastic explosives or small (e.g., ≤10 μm particles of RDX or other explosives or oxidizers can be detected, identified, and quantified in the field. With 300 mW excitation energy, concentrations of RDX and PETN can be detected and reconstructed in the case of thin Semtex smears, but further work is needed to push detection limits of areal dosages to the ~1 μg/cm2 level. We describe the performance of several probe/spectrograph combinations and show preliminary data for particle detection, calibration and detection linearity for mixed compounds, and so forth.

  14. On the BRST and finite field dependent BRST of a model where vector and axial vector interaction get mixed up with different weight

    CERN Document Server

    Rahaman, Anisur

    2016-01-01

    The generalized version of a lower dimensional model where vector and axial vector interaction get mixed up with different weight is considered. The bosonized version of which does not posses the local gauge symmetry. An attempt has been made here to construct BRST invariant reformulation of this model using Batalin Fradlin and Vilkovisky formalism. It is found that the extra field needed to make it gauge invariant turns into Wess-Zumino scalar with appropriate choice of gauge fixing. An application of finite field dependent BRST and anti-BRST transformation is also made here in order to show the transmutation between the BRST symmetric and the usual non-symmetric version of the model.

  15. Study of axial magnetic effect

    International Nuclear Information System (INIS)

    The Axial Magnetic Effect manifests itself as an equilibrium energy flow of massless fermions induced by the axial (chiral) magnetic field. Here we study the Axial Magnetic Effect in the quenched SU(2) lattice gauge theory with massless overlap fermions at finite temperature. We numerically observe that in the low-temperature hadron phase the effect is absent due to the quark confinement. In the high-temperature deconfinement phase the energy flow is an increasing function of the temperature which reaches the predicted asymptotic T2 behavior at high temperatures. We find, however, that energy flow is about one order of magnitude lower compared to a theoretical prediction

  16. EXPERIMENTAL RESEARCH ON AERODYNAMIC PERFORMANCE AND EXIT FLOW FIELD OF LOW PRESSURE AXIAL FLOW FAN WITH CIRCUMFERENTIAL SKEWED BLADES

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    In this article, the low pressure axial flow fan with circumferential skewed rotor blade, including the radial blade, the forward-skewed blade and the backward-skewed blade, was studied with experimental methods. The aerodynamic performance of the rotors was measured. At the design condition at outlet of the rotors, detailed flow measurements were performed with a five-hole probe and a Hot-Wire Anemometer (HWA). The results show that compared to the radial rotor, the forward-skewed rotor demonstrates a wider Stable Operating Range (SOR), is able to reduce the total pressure loss in the hub region and make main loading of blade accumulating in the mid-span region. There is a wider wake in the upper mid-span region of the forward-skewed rotor. Compared to the radial rotor, in the backward-skewed rotor there is higher total pressure loss near the hub and shroud regions and lower loss in the mid-span region. In addition, the velocity deficit in the wake is lower at mid-span of the backward-skewed rotor than the forward-skewed rotor.

  17. Characterization of extended range Bonner Sphere Spectrometers in the CERF high-energy broad neutron field at CERN

    Science.gov (United States)

    Agosteo, S.; Bedogni, R.; Caresana, M.; Charitonidis, N.; Chiti, M.; Esposito, A.; Ferrarini, M.; Severino, C.; Silari, M.

    2012-12-01

    The accurate determination of the ambient dose equivalent in the mixed neutron-photon fields encountered around high-energy particle accelerators still represents a challenging task. The main complexity arises from the extreme variability of the neutron energy, which spans over 10 orders of magnitude or more. Operational survey instruments, which response function attempts to mimic the fluence-to-ambient dose equivalent conversion coefficient up to GeV neutrons, are available on the market, but their response is not fully reliable over the entire energy range. Extended range rem counters (ERRC) do not require the exact knowledge of the energy distribution of the neutron field and the calibration can be done with a source spectrum. If the actual neutron field has an energy distribution different from the calibration spectrum, the measurement is affected by an added uncertainty related to the partial overlap of the fluence-to-ambient dose equivalent conversion curve and the response function. For this reason their operational use should always be preceded by an "in-field" calibration, i.e. a calibration made against a reference instrument exposed in the same field where the survey-meter will be employed. In practice the extended-range Bonner Sphere Spectrometer (ERBSS) is the only device which can serve as reference instrument in these fields, because of its wide energy range and the possibility to assess the neutron fluence and the ambient dose equivalent (H*(10)) values with the appropriate accuracy. Nevertheless, the experience gained by a number of experimental groups suggests that mandatory conditions for obtaining accurate results in workplaces are: (1) the use of a well-established response matrix, thus implying validation campaigns in reference monochromatic neutrons fields, (2) the expert and critical use of suitable unfolding codes, and (3) the performance test of the whole system (experimental set-up, elaboration and unfolding procedures) in a well

  18. Performance of the multidetector NSE spectrometer SPAN at BENSC

    International Nuclear Information System (INIS)

    The NSE precession field, which is created by three pairs of coils with diameters 1, 3 and 4.8 m respectively, is the pecularity in the design of SPAN. Each pair is mounted in a Helmholtz-like fashion, with the electric currents oriented oppositely to each other, one coil above and one coil below the horizontal scattering plane. The maximum magnetic field integral is 0.06 T m typically 1/3 that of IN11. The field created by the coils with 3 m diameter is horizontal with axial symmetry. The coils with a diameter of 1 m shape the magnetic field around the sample. They produce at the sample a very homogeneous adjustable vertical field, which assures the axial symmetry of the magnetic configuration. A first series of NSE measurements are presented, which show that only little field adjustment is requires to satisfy the exact echo condition (phase) simultaneously for a large range of scattering angles and confirm the high axial symmetry of the precession field. The resolution of the spectrometer meets the expectations (∼ 8 ns maximum Fourier time at 9 A) and the results show that the new magnetic field configuration of SPAN is particularly appropriate for multidetector NSE over a wide angular range. (author)

  19. Mass Effect on Axial Charge Dynamics

    CERN Document Server

    Guo, Er-dong

    2016-01-01

    We studied effect of finite quark mass on the dynamics of axial charge using the D3/D7 model in holography. The mass term in axial anomaly equation affects both the fluctuation (generation) and dissipation of axial charge. We studied the dependence of the effect on quark mass and external magnetic field. For axial charge generation, we calculated the mass diffusion rate, which characterizes the helicity flipping rate. The rate is a non-monotonous function of mass and can be significantly enhanced by the magnetic field. The diffusive behavior is also related to a divergent susceptibility of axial charge. For axial charge dissipation, we found that in the long time limit, the mass term dissipates all the charge effectively generated by parallel electric and magnetic fields. The result is consistent with a relaxation time approximation. The rate of dissipation through mass term is a monotonous increasing function of both quark mass and magnetic field.

  20. Characterization of extended range Bonner Sphere Spectrometers in the CERF high-energy broad neutron field at CERN

    International Nuclear Information System (INIS)

    The accurate determination of the ambient dose equivalent in the mixed neutron–photon fields encountered around high-energy particle accelerators still represents a challenging task. The main complexity arises from the extreme variability of the neutron energy, which spans over 10 orders of magnitude or more. Operational survey instruments, which response function attempts to mimic the fluence-to-ambient dose equivalent conversion coefficient up to GeV neutrons, are available on the market, but their response is not fully reliable over the entire energy range. Extended range rem counters (ERRC) do not require the exact knowledge of the energy distribution of the neutron field and the calibration can be done with a source spectrum. If the actual neutron field has an energy distribution different from the calibration spectrum, the measurement is affected by an added uncertainty related to the partial overlap of the fluence-to-ambient dose equivalent conversion curve and the response function. For this reason their operational use should always be preceded by an “in-field” calibration, i.e. a calibration made against a reference instrument exposed in the same field where the survey-meter will be employed. In practice the extended-range Bonner Sphere Spectrometer (ERBSS) is the only device which can serve as reference instrument in these fields, because of its wide energy range and the possibility to assess the neutron fluence and the ambient dose equivalent (H⁎(10)) values with the appropriate accuracy. Nevertheless, the experience gained by a number of experimental groups suggests that mandatory conditions for obtaining accurate results in workplaces are: (1) the use of a well-established response matrix, thus implying validation campaigns in reference monochromatic neutrons fields, (2) the expert and critical use of suitable unfolding codes, and (3) the performance test of the whole system (experimental set-up, elaboration and unfolding procedures) in a well

  1. Impact of detector design on imaging performance of a long axial field-of-view, whole-body PET scanner

    Science.gov (United States)

    Surti, S.; Karp, J. S.

    2015-07-01

    Current generation of commercial time-of-flight (TOF) PET scanners utilize 20-25 mm thick LSO or LYSO crystals and have an axial FOV (AFOV) in the range of 16-22 mm. Longer AFOV scanners would provide increased intrinsic sensitivity and require fewer bed positions for whole-body imaging. Recent simulation work has investigated the sensitivity gains that can be achieved with these long AFOV scanners, and has motivated new areas of investigation such as imaging with a very low dose of injected activity as well as providing whole-body dynamic imaging capability in one bed position. In this simulation work we model a 72 cm long scanner and prioritize the detector design choices in terms of timing resolution, crystal size (spatial resolution), crystal thickness (detector sensitivity), and depth-of-interaction (DOI) measurement capability. The generated list data are reconstructed with a list-mode OSEM algorithm using a Gaussian TOF kernel that depends on the timing resolution and blob basis functions for regularization. We use lesion phantoms and clinically relevant metrics for lesion detectability and contrast measurement. The scan time was fixed at 10 min for imaging a 100 cm long object assuming a 50% overlap between adjacent bed positions. Results show that a 72 cm long scanner can provide a factor of ten reduction in injected activity compared to an identical 18 cm long scanner to get equivalent lesion detectability. While improved timing resolution leads to further gains, using 3 mm (as opposed to 4 mm) wide crystals does not show any significant benefits for lesion detectability. A detector providing 2-level DOI information with equal crystal thickness also does not show significant gains. Finally, a 15 mm thick crystal leads to lower lesion detectability than a 20 mm thick crystal when keeping all other detector parameters (crystal width, timing resolution, and DOI capability) the same. However, improved timing performance with 15

  2. Impact of detector design on imaging performance of a long axial field-of-view, whole-body PET scanner

    International Nuclear Information System (INIS)

    Current generation of commercial time-of-flight (TOF) PET scanners utilize 20–25 mm thick LSO or LYSO crystals and have an axial FOV (AFOV) in the range of 16–22 mm. Longer AFOV scanners would provide increased intrinsic sensitivity and require fewer bed positions for whole-body imaging. Recent simulation work has investigated the sensitivity gains that can be achieved with these long AFOV scanners, and has motivated new areas of investigation such as imaging with a very low dose of injected activity as well as providing whole-body dynamic imaging capability in one bed position. In this simulation work we model a 72 cm long scanner and prioritize the detector design choices in terms of timing resolution, crystal size (spatial resolution), crystal thickness (detector sensitivity), and depth-of-interaction (DOI) measurement capability. The generated list data are reconstructed with a list-mode OSEM algorithm using a Gaussian TOF kernel that depends on the timing resolution and blob basis functions for regularization. We use lesion phantoms and clinically relevant metrics for lesion detectability and contrast measurement. The scan time was fixed at 10 min for imaging a 100 cm long object assuming a 50% overlap between adjacent bed positions. Results show that a 72 cm long scanner can provide a factor of ten reduction in injected activity compared to an identical 18 cm long scanner to get equivalent lesion detectability. While improved timing resolution leads to further gains, using 3 mm (as opposed to 4 mm) wide crystals does not show any significant benefits for lesion detectability. A detector providing 2-level DOI information with equal crystal thickness also does not show significant gains. Finally, a 15 mm thick crystal leads to lower lesion detectability than a 20 mm thick crystal when keeping all other detector parameters (crystal width, timing resolution, and DOI capability) the same. However, improved timing performance with 15

  3. Improving the spectral resolution of flat-field concave grating miniature spectrometers by dividing a wide spectral band into two narrow ones.

    Science.gov (United States)

    Zhou, Qian; Pang, Jinchao; Li, Xinghui; Ni, Kai; Tian, Rui

    2015-11-10

    In this study, a new flat-field concave grating miniature spectrometer is proposed with improved resolution across a wide spectral band. A mirror is added to a conventional concave grating spectrometer and placed near the existing detector array, allowing a wide spectral band to be divided into two adjacent subspectral bands. One of these bands is directly detected by the detector, and the other is indirectly analyzed by the same detector after being reflected by the mirror. These two subspectral bands share the same entrance slit, concave grating, and detector, which allows for a compact size, while maintaining an improved spectral resolution across the entire spectral band. The positions of the mirror and other parameters of the spectrometer are designed by a computer procedure and the optical design software ZEMAX. Simulation results show that the resolution of this kind of flat-field concave grating miniature spectrometer is better than 1.6 nm across a spectral band of 700 nm. Experiments based on three laser sources reveal that the measured resolutions are comparable to the simulated ones, with a maximum relative error between them of less than 19%. PMID:26560772

  4. Chopper spectrometers

    International Nuclear Information System (INIS)

    Chopper spectrometers are devices which measure the dynamics of condensed systems expressed in terms of the scattering function. The scattering function depends on the energy and momentum transfers which are related to the initial and final neutron wave vectors. The resolution of the instrument is limited by the time-of-flight measurements on the scattered beam but the wide range of accessible energy and momentum transfers make chopper spectrometers popular. Several examples of experiments using chopper spectrometers are presented

  5. SU-D-9A-04: Brain PET/CT Imaging On a Scanner with a Large Axial Field-Of-View

    International Nuclear Information System (INIS)

    Purpose: Large axial field-of-view (FOV) PET/CT scanners are valued for high sensitivity. Brain PET image quality may depend on the head position within the FOV. We investigated the precision of activity estimation for brain PET imaging when the brain was positioned at the end (END) and in the middle (CEN) of the FOV. The additional CT dose for the CEN position was recorded. Methods: An image quality (Jaszczak) phantom and a striatal phantom were filled with F-18 and positioned in END and CEN locations. For each phantom and each location, we acquired a ∼1-hr listmode PET, rebinned the data into 10 frames with equal number of coincidence events, and reconstructed each frame using an iterative algorithm. For the striatal phantom, END and CEN were compared by drawing on each image three regions of interest (ROI) in axially separated uniform areas. The standard deviation of the activity estimation within each ROI was averaged over the 10 images. The coefficient of variation (CV) for activity estimation was calculated at each position. Image quality was assessed by inspecting the resolution bar pattern in the Jaszczak phantom at two different head positions. Results: The CV was the lowest for ROIs near the center of the FOV. For slices near the end, not only was the CV highest, but also the resolution pattern was degraded. CTDIvol summarized in the dose report indicated that the CT dose was ∼ 10% higher for CEN as compared to END position. Conclusion: Positioning the brain in the middle of the FOV in a large FOV PET/CT scanner allows more precise measurement of tracer uptake and better image quality at the cost of increased CT dose. For the end location longer scan times may minimize image quality degradation without any additional CT dose

  6. Correlating morphology and the spectroscopy of colour centres in diamond using a combined near-field scanning optical microscope and Raman spectrometer

    International Nuclear Information System (INIS)

    Full text: The correlation of the morphology of isolated diamond nanocrystals and thin film Chemical Vapour Deposited (CVD) diamond with fluorescence, photoluminescence and Raman spectroscopy of colour centres is studied using a combined Near-Field Scanning Optical Microscope (NSOM) and Raman spectrometer. The location, concentration and spectra of defects such as the Nitrogen-Vacancy (NV) and Nickle centres in diamond, which are of interest as single photon sources and in quantum computing applications, are reported. Copyright (2005) Australian Institute of Physics

  7. Measuring production-dissolution rates of marine biogenic silica by 30Si-isotope dilution using a high-resolution sector field inductively coupled plasma mass spectrometer

    OpenAIRE

    Fripiat, F.; Corvaisier, Rudolph; Navez, Jacques; Elskens, M.; Schoemann, Véronique; Leblanc, Karine; Andre, Luc; D. Cardinal

    2009-01-01

    Regional and seasonal variability of the Si dissolution:production ratios in the surface ocean have not been well assessed. Here, we propose a new method for determining these rates, using the 30Si-isotopic dilution technique with a high-resolution sector field inductively coupled plasma mass spectrometer (HR-SF-ICP-MS). Relative analytical precision of the isotopic measurement is better than 1%, similar to that obtained by thermal ionization-quadrupole mass spectrometry (TIMS). Accuracy and ...

  8. Vectorial versus axial goldstone bosons

    International Nuclear Information System (INIS)

    The Yukawa interactions of fermions with Goldstone bosons are given in closed form for an arbitrary renormalizable field theory to all orders of perturbation theory or for a general effective Lagrangian. Although the diagonal couplings are always pseudoscalar there is an important difference between spontaneously broken vector and axial-vector global symmetries. Compared to the axial case, the diagonal douplings of 'vectorial' Goldstone bosons to charged fermions are suppressed by mixing angles or appear only via radiative corrections involving gauge fields. This general result may be relevant for the problem of flavour symmetry breaking in composite models. (Author)

  9. A new signal restoration method based on deconvolution of the Point Spread Function (PSF) for the Flat-Field Holographic Concave Grating UV spectrometer system

    Science.gov (United States)

    Dai, Honglin; Luo, Yongdao

    2013-12-01

    In recent years, with the development of the Flat-Field Holographic Concave Grating, they are adopted by all kinds of UV spectrometers. By means of single optical surface, the Flat-Field Holographic Concave Grating can implement dispersion and imaging that make the UV spectrometer system design quite compact. However, the calibration of the Flat-Field Holographic Concave Grating is very difficult. Various factors make its imaging quality difficult to be guaranteed. So we have to process the spectrum signal with signal restoration before using it. Guiding by the theory of signals and systems, and after a series of experiments, we found that our UV spectrometer system is a Linear Space- Variant System. It means that we have to measure PSF of every pixel of the system which contains thousands of pixels. Obviously, that's a large amount of calculation .For dealing with this problem, we proposes a novel signal restoration method. This method divides the system into several Linear Space-Invariant subsystems and then makes signal restoration with PSFs. Our experiments turn out that this method is effective and inexpensive.

  10. Origin of axial current in scyllac

    International Nuclear Information System (INIS)

    The origin of the axial current observed in Scyllac (a high beta stellarator experiment) is discussed. A shaped coil and/or helical winding produce rotational transform which links magnetic lines of force to the plasma column and the axial current is induced electromagnetically. This phenomenon is inherent in a pulsed high-beta stellarator. The rotational transform produced by the induced axial current is much smaller than that associated with the l = 1, 0 equilibrium fields. The effect of the axial current on the equilibrium and stability of the plasma column is thus small. It is also shown that the magnetic field shear near a plasma surface is very strong

  11. Dosimetry and microdosimetry using LET spectrometer based on the track-etch detector: radiotherapy Bremsstrahlung beam, onboard aircraft radiation field

    International Nuclear Information System (INIS)

    The spectrometer of linear energy transfer (Let) based on the chemically etched poly-allyl-diglycol-carbonate (P.A.D.C.) track-etch detector was developed several years ago in our institute. This Let spectrometer enables determining Let of particles approximately from 10 to 700 keV/μm. From the Let spectra, dose characteristics can be calculated. The contribution presents the Let spectra and other dosimetric characteristics obtained onboard a commercial aircraft during more than 6 months long exposure and in the 18 MV radiotherapy Bremsstrahlung beam. (authors)

  12. Experimental Investigation on the Influence of Axial Magnetic Field Distribution on Resisting the Constriction of a High-Current Vacuum Arc

    Institute of Scientific and Technical Information of China (English)

    SHI Zongqian; LIU Zhigang; JIA Shenli; SONG Xiaochuan; WANG Lijun

    2009-01-01

    Effect of the axial magnetic field (AMF) on resisting the constriction of a high-current vacuum arc is studied in this paper. Two typical AMF distributions were investigated, i.e., the traditional bell-shaped AMF, and the saddle-shaped AMF. Experiments were conducted in a detachable vacuum chamber with a rms arc current in the range of 10 kA to 25 kA. The arc column was photographed by a high-speed digital camera with an exposure time of 2 microseconds. The constriction of the vacuum arc was compared by processing the images of the arc column under the two different field configurations and numerically determining the dimensions of the arc column near the electrodes. It was also confirmed that the AMF distribution had a signifcant influence on its effectiveness in resisting arc constriction, Furthermore, the AMF strength near the periphery of the arc is more influential than that at the centre of the electrodes in resisting arc constriction.

  13. The 4π-fragment-spectrometer FOBOS

    International Nuclear Information System (INIS)

    The 4π-fragment-spectrometer FOBOS developed for heavy ion research at beam energies of 10-100AMeV has been commissioned for physical experiments at the FLNR of the Joint Institute for Nuclear Research. Based on the logarithmic detector principle, it is able to register charged fragments from protons up to heavy residual nuclei in a large dynamic range. Position sensitive avalanche counters, axial ionization chambers and CsI(Tl) scintillation detectors are arranged in three concentric detector shells. An array of phoswich detectors is used as a more granular forward detector at narrow polar angles. The modular concept of FOBOS allows for different experimental application in the field of exclusive fragment spectroscopy at medium multiplicities

  14. Effect of Partial Shrouds on the Performance and Flow Field of a Low-Aspect-Ratio Axial-Flow Fan Rotor

    Directory of Open Access Journals (Sweden)

    N. Sitaram

    2011-01-01

    Full Text Available The flow field at the rotor exit of a low aspect ratio axial flow fan for different tip geometries and for different flow coefficients is measured in the present study. The following configurations are tested: (1 rotor without partial shroud, designated as rotor (wos, (2 rotor with partial shroud, designated as rotor (ws, and (3 rotor with perforated (perforations in the shape of discrete circular holes partial shroud, designated as rotor (wps. From steady state measurements, the performance of rotor (wps is found to be the best. Both the rotors with partial shrouds have stalled at a higher flow coefficient compared to that of rotor (wos. From periodic flow measurements, it is concluded that the low velocity region near the tip section is considerably reduced with the use of partial shrouds with perforations. The extent of this low velocity region for both rotor (wos and rotor (wps increases with decreasing flow coefficient due to increased stage loading. This core of low momentum fluid has moved inwards of the annulus and towards the pressure side as the flow coefficient decreases. The extent of the low momentum fluid is smaller for rotor (wps than that of rotor (wos at all flow coefficients.

  15. Simulation of an Axial Vircator

    CERN Document Server

    Tikhomirov, V V

    2013-01-01

    An algorithm of particle-in-cell simulations is described and tested to aid further the actual design of simple vircators working on axially symmetric modes. The methods of correction of the numerical solution, have been chosen and jointly tested, allow the stable simulation of the fast nonlinear multiflow dynamics of virtual cathode formation and evolution, as well as the fields generated by the virtual cathode. The selected combination of the correction methods can be straightforwardly generalized to the case of axially nonsymmetric modes, while the parameters of these correction methods can be widely used to improve an agreement between the simulation predictions and the experimental data.

  16. The response functions of a 3He Bonner Spectrometer and their experimental verification in high energy neutron fields

    International Nuclear Information System (INIS)

    The neutron response functions for a Bonner Sphere Spectrometer (BSS) with 3He proportional counter were calculated employing the MCNP and LAHET Monte Carlo codes for the neutron energy range from 10 MeV to 1 GeV. The MCNP calculations were extended up to 100 MeV using the neutron cross-sections from the transport data libraries LA-100 of LANL. The effect of the different physics models implemented in the LAHET code on the response of the Bonner spectrometer are documented and the possible reasons are discussed. The MCNP and LAHET results are also compared with calculations using the Monte Carlo high energy transport code HADRON. Verification experiments were conducted at the CERN high energy calibration facility which gave some insight to the question how appropriate the physical models are which are used for the calculation of the BSS responses. (author)

  17. Dissipative Axial Inflation

    CERN Document Server

    Notari, Alessio

    2016-01-01

    We analyze in detail the background cosmological evolution of a scalar field coupled to a massless abelian gauge field through an axial term $\\frac{\\phi}{f_\\gamma} F \\tilde{F}$, such as in the case of an axion. Gauge fields in this case are known to experience tachyonic growth and therefore can backreact on the background as an effective dissipation into radiation energy density $\\rho_R$, which which can lead to inflation without the need of a flat potential. We analyze the system, for momenta $k$ smaller than the cutoff $f_\\gamma$, including numerically the backreaction. We consider the evolution from a given static initial condition and explicitly show that, if $f_\\gamma$ is smaller than the field excursion $\\phi_0$ by about a factor of at least ${\\cal O} (20)$, there is a friction effect which turns on before that the field can fall down and which can then lead to a very long stage of inflation with a generic potential. In addition we find superimposed oscillations, which would get imprinted on any kind of...

  18. New schemes of static mass spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Baisanov, O.A. [Military Institute of Air Defense Forces, Aktobe (Kazakhstan); Doskeyev, G.A. [Aktobe State University named after K. Zhubanov, Aktobe (Kazakhstan); Spivak-Lavrov, I.F., E-mail: baisanov@mail.ru [Aktobe State University named after K. Zhubanov, Aktobe (Kazakhstan)

    2011-07-21

    Different possibilities to increase the 'quality', or Q-quantity, of static mass spectrometers by expanding the ion beam before it enters the magnetic field are analyzed. The design of mass spectrometers using a cone-shaped achromatic prism is discussed. Different variants of achromatic mass spectrometers using electrostatic prisms and sector magnetic fields are also considered.

  19. New schemes of static mass spectrometers

    International Nuclear Information System (INIS)

    Different possibilities to increase the 'quality', or Q-quantity, of static mass spectrometers by expanding the ion beam before it enters the magnetic field are analyzed. The design of mass spectrometers using a cone-shaped achromatic prism is discussed. Different variants of achromatic mass spectrometers using electrostatic prisms and sector magnetic fields are also considered.

  20. Spectrometer gun

    Science.gov (United States)

    Waechter, David A.; Wolf, Michael A.; Umbarger, C. John

    1985-01-01

    A hand-holdable, battery-operated, microprocessor-based spectrometer gun includes a low-power matrix display and sufficient memory to permit both real-time observation and extended analysis of detected radiation pulses. Universality of the incorporated signal processing circuitry permits operation with various detectors having differing pulse detection and sensitivity parameters.

  1. Spectrometer gun

    International Nuclear Information System (INIS)

    A hand-holdable, battery-operated, microprocessor-based spectrometer gun includes a low-power matrix display and sufficient memory to permit both real-time observation and extended analysis of detected radiation pulses. Universality of the incorporated signal processing circuitry permits operation with various detectors having differing pulse detection and sensitivity parameters

  2. The HERMES Spectrometer

    OpenAIRE

    Ackerstaff, K.

    1998-01-01

    The HERMES experiment is collecting data on inclusive and semi-inclusive deep inelastic scattering of polarised positrons from polarised targets of H, D, and He. These data give information on the spin structure of the nucleon. This paper describes the forward angle spectrometer built for this purpose. The spectrometer includes numerous tracking chambers (micro-strip gas chambers, drift and proportional chambers) in front of and behind a 1.3 T.m magnetic field, as well as an extensive set of ...

  3. Method to compensate the dispersion of kinetic energy resolution in a velocity map imaging spectrometer

    International Nuclear Information System (INIS)

    Here we present a novel method to improve the kinetic energy resolution of a velocity map imaging(VMI) spectrometer. The main modifications, compared to the original design of Eppink and Parker (1997 Rev. Sci. Instrum. 68 3477), are two additional grid electrodes. One of the electrodes is a grounded grid and the other is an arc-shaped grid with negative voltages (or positive voltages for an ions spectrometer). The arc-shaped electrode is axially symmetrical around the spectrometer axis. The field constructed by the two electrodes is to compensate the dispersion of the ‘v’-shaped energy resolution. Simulations by SIMION and reconstructions by the basis set expansion Abel transform method show that the kinetic energy resolution can be improved drastically by our new method. Furthermore, the accuracy in the determination of the kinetic energy of ion/electrons remains unchanged with respect to the original design. (paper)

  4. Moessbauer spectrometers

    International Nuclear Information System (INIS)

    The recent advances in Moessbauer spectrometers, their parameters and electronic circuits are reviewed. The transfer functions of two mathematical models of electromechanical transducers (with discrete and continuously distributed parameters) are given. The problems of drive and pick-up parts optimisation are discussed. The electronic circuits for reference triangle wave generators with reduced nonlinearity are described. The influence of the positive and negative corrections of the Moessbauer spectrometer feedback loop on the error-signal is discussed. A flow chart for adaptive minimization of the error-signal is presented. In addition a special drive system using piezoelements with an appropriate digital sinusoidal generator is also included. A flow chart of the system for data acquisition is shown. (author)

  5. Moessbauer spectrometers

    International Nuclear Information System (INIS)

    The recent advances in Moessbauer spectrometers, their parameters and electronic circuits are reviewed. The transfer functions of two mathematical models of electromechanical transducers (with discrete and continuously distributed parameters) are given. The problem of optimization of the drive and pick-up parts is discussed. The electronic circuits for reference triangle wave generators with reduced nonlinearity are described. A Moessbauer spectrometer with both positive and negative corrections in the feedback loop is described. The influence of these corrections on the error-signal is discussed. A flow chart for adaptive minimization of the error-signal is presented. In addition a special drive system using piezo elements with an appropriate digital sinusoidal generator is also included. A flow chart of the system using PC for data accumulation is shown. (author)

  6. Electron spectrometers

    International Nuclear Information System (INIS)

    Measurements made using electron spectrometers can lead to the determination of all the parameters that fully characterize the photoionization process. The measurements fall into three categories: the angular independent flux of the photoelectrons which leads to the partial cross section, the angular distribution of the photoelectrons, and the spin of the photoelectrons. The majority of this paper is concerned with electron energy analyzers which can be used to measure both the partial cross section and the angular distribution

  7. The Effects of 910-MHz Electromagnetic Field on Rat Cranial Arachnoid and Dura Mater Collagen. The Axial Periodicity of Collagen Fibrils

    OpenAIRE

    Margaret Tzaphlidou; Evangelos Fotiou

    2004-01-01

    The axial periodicity of rat arachnoid and dura mater collagen fibrils exposed to 910 MHz for 2 h/day for 30 consecutive days was measured by means of image analysis of electron-optical data. Such measurements were compared with those from sham-exposed animals. These measurements reveal that on exposure, the intermolecular interactions during collagen fibril assembly are affected.

  8. Simulation of an Axial Vircator

    OpenAIRE

    Tikhomirov, V. V.; Siahlo, S. E.

    2013-01-01

    An algorithm of particle-in-cell simulations is described and tested to aid further the actual design of simple vircators working on axially symmetric modes. The methods of correction of the numerical solution, have been chosen and jointly tested, allow the stable simulation of the fast nonlinear multiflow dynamics of virtual cathode formation and evolution, as well as the fields generated by the virtual cathode. The selected combination of the correction methods can be straightforwardly gene...

  9. Holographic fabrication of large-constant concave gratings for wide-range flat-field spectrometers with the addition of a concave lens.

    Science.gov (United States)

    Zhou, Qian; Li, Xinghui; Ni, Kai; Tian, Rui; Pang, Jinchao

    2016-01-25

    We present a new design for the fabrication of concave gratings with large grating constants for flat-field miniature spectrometers with a wide spectral band. In this new design, one of the two optical paths for the holographic lithography of a curved grating structure with variable line spacing is modified by adding a concave lens in front of the point source. The addition of the concave lens allows the real point source, as well as the spatial filter for generating this point source, to be moved back. In this manner, the two spatial filters for generating two point sources are separated. Avoiding the physical conflict between these two spatial filters reduces the difficulty of fabricating large-constant concave gratings. Experimental results verify the feasibility of the proposed design in fabricating concave gratings with large grating constants. The resolution of a spectrometer using the fabricated concave grating is evaluated and found to be better than 1.1 nm across a spectral band ranging from 360 nm to 825 nm. PMID:26832458

  10. Observations and Modeling of the Green Ocean Amazon 2014/15: Hydroxyl Radical (OH) Chemical Ionization Mass Spectrometer (CIMS) Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Saewung [Univ. of California, Irvine, CA (United States)

    2016-05-01

    The University of California, Irvine, science team (Dr. Saewung Kim, Dr. Roger Seco, Dr. Alex Guenther, and Dr. Jim Smith) deployed a chemical ionization mass spectrometer system for hydroxyl radical (OH) and sulfuric acid quantifications. As part of the GoAmazon 2014/15 field campaign. Hydroxyl radical determines tropospheric oxidation capacity and had been expected to be very low in the pristine rain forest region such as the Brazilian Amazon because of the presence of significant levels of highly reactive biogenic volatile organic compounds and very low levels of NO, which is an OH recycling agent. However, several recent in situ OH observations provided by a laser-induced fluorescence system reported unaccountably high OH concentrations. To address this discrepancy, a series of laboratory and theoretical studies has postulated chemical reaction mechanisms of isoprene that may regenerate OH in photo-oxidation processes. Along with these efforts, potential artifacts on the laser induced fluorescence system from isoprene and its oxidation products also have been explored. Therefore, the first chemical ionization mass spectrometer observations at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility’s T3 site in Manacapuru, Brazil, are expected to provide a critical experimental constraint to address uncertainty in constraining oxidation capacity over pristine rain forest environments. In addition, we deployed a National Center for Atmospheric Research (NCAR) proton transfer reaction time-of-flight mass spectrometer to characterize atmospheric volatile organic compound levels, especially isoprene and its oxidation products, which are critical input parameters for box modeling to simulate OH with different isoprene photo-oxidation schemes. As there has been no report on noticeable new particle formation events, our first in situ sulfuric acid observations in the Amazon rain forest were expected to constrain the

  11. 基于Offner结构分视场成像光谱仪光学设计%Sub-Field Imaging Spectrometer Design Based on Offner Structure

    Institute of Scientific and Technical Information of China (English)

    吴从均; 颜昌翔; 刘伟; 代虎

    2013-01-01

    To satisfy imaging spectrometers's miniaturization,lightweight and large field requirements in space application,the current optical design of imaging spectrometer with Offner structure was analyzed,and an simple method to design imaging spectrometer with concave grating based on current ways was given.Using the method offered,the sub-field imaging spectrometer with 400 km altitude,0.4~1.0 μm wavelength range,5 F-number of 720 mm focal length and 4.3°total field was designed.Optical fiber was used to transfer the image in telescope's focal plane to three slits arranged in the same plane so as to achieve subfield.The CCD detector with 1 024× 1 024 and 18 μm× 18μm was used to receive the image of the three slits after dispersing.Using ZEMAX software optimization and tolerance analysis,the system can satisfy 5 nm spectrum resolution and 5 m field resolution,and the MTF is over 0.62 with 28 lp · mm-1.The field of the system is almost 3 times that of similar instruments used in space probe.%为满足航天应用中仪器小型和轻量化、大视场的观测要求,通过分析现有Offner成像光谱仪,给出了一种简单的采用凸面光栅设计成像光谱仪的方法.并据此方法设计了一应用于400 km高度,波段范围为0.4~1 μm,焦距为720 mm,F数为5,全视场大小为4.3°的分视场成像光谱仪系统.分视场采用光纤将望远系统的细长像面连接到光谱仪的三个不同狭缝而实现.三狭缝光谱面共用一个像元数为1 024×1 024,像元大小18μm×18μm的CCD探测器.通过ZEMAX软件优化和公差分析后,系统在28 lp·mm-1处MTF优于0.62,光谱分辨率优于5nm,地面分辨率小于10 m,能很好的满足大视场应用要求,该光学系统刈幅宽度相当于国内已研制成功的同类最好仪器的三倍.

  12. BWR AXIAL PROFILE

    International Nuclear Information System (INIS)

    The purpose of this calculation is to develop axial profiles for estimating the axial variation in burnup of a boiling water reactor (BWR) assembly spent nuclear fuel (SNF) given the average burnup of an assembly. A discharged fuel assembly typically exhibits higher burnup in the center and lower burnup at the ends of the assembly. Criticality safety analyses taking credit for SNF burnup must account for axially varying burnup relative to calculations based on uniformly distributed assembly average burnup due to the under-burned tips. Thus, accounting for axially varying burnup in criticality analyses is also referred to as accounting for the ''end effect'' reactivity. The magnitude of the reactivity change due to ''end effect'' is dependent on the initial assembly enrichment, the assembly average burnup, and the particular axial profile characterizing the burnup distribution. The set of bounding axial profiles should incorporate multiple BWR core designs and provide statistical confidence (95 percent confidence that 95 percent of the population is bound by the profile) that end nodes are conservatively represented. The profiles should also conserve the overall burnup of the fuel assembly. More background on BWR axial profiles is provided in Attachment I

  13. BWR AXIAL PROFILE

    Energy Technology Data Exchange (ETDEWEB)

    J. Huffer

    2004-09-28

    The purpose of this calculation is to develop axial profiles for estimating the axial variation in burnup of a boiling water reactor (BWR) assembly spent nuclear fuel (SNF) given the average burnup of an assembly. A discharged fuel assembly typically exhibits higher burnup in the center and lower burnup at the ends of the assembly. Criticality safety analyses taking credit for SNF burnup must account for axially varying burnup relative to calculations based on uniformly distributed assembly average burnup due to the under-burned tips. Thus, accounting for axially varying burnup in criticality analyses is also referred to as accounting for the ''end effect'' reactivity. The magnitude of the reactivity change due to ''end effect'' is dependent on the initial assembly enrichment, the assembly average burnup, and the particular axial profile characterizing the burnup distribution. The set of bounding axial profiles should incorporate multiple BWR core designs and provide statistical confidence (95 percent confidence that 95 percent of the population is bound by the profile) that end nodes are conservatively represented. The profiles should also conserve the overall burnup of the fuel assembly. More background on BWR axial profiles is provided in Attachment I.

  14. Development of a Robust, High Current, Low Power Field Emission Electron Gun for a Spaceflight Reflectron Time-of-Flight Mass Spectrometer

    Science.gov (United States)

    Southard, Adrian E.; Getty, Stephanie A.; Feng, Steven; Glavin, Daniel P.; Auciello, Orlando; Sumant, Anirudha

    2012-01-01

    Carbon materials, including carbon nanotubes (CNTs) and nitrogen-incorporated ultrananocrystalline diamond (N-UNCD), have been of considerable interest for field emission applications for over a decade. In particular, robust field emission materials are compelling for space applications due to the low power consumption and potential for miniaturization. A reflectron time-of-flight mass spectrometer (TOF-MS) under development for in situ measurements on the Moon and other Solar System bodies uses a field emitter to generate ions from gaseous samples, using electron ionization. For these unusual environments, robustness, reliability, and long life are of paramount importance, and to this end, we have explored the field emission properties and lifetime of carbon nanotubes and nitrogen-incorporated ultrananocrystalline diamond (N-UNCD) thin films, the latter developed and patented by Argonne National Laboratory. We will present recent investigations of N-UNCD as a robust field emitter, revealing that this material offers stable performance in high vacuum for up to 1000 hours with threshold voltage for emission of about 3-4 V/lJm and current densities in the range of tens of microA. Optimizing the mass resolution and sensitivity of such a mass spectrometer has also been enabled by a parallel effort to scale up a CNT emitter to an array measuring 2 mm x 40 mm. Through simulation and experiment of the new extended format emitter, we have determined that focusing the electron beam is limited due to the angular spread of the emitted electrons. This dispersion effect can be reduced through modification of the electron gun geometry, but this reduces the current reaching the ionization region. By increasing the transmission efficiency of the electron beam to the anode, we have increased the anode current by two orders of magnitude to realize a corresponding enhancement in instrument sensitivity, at a moderate cost to mass resolution. We will report recent experimental and

  15. Estimating the background count rate in the energy field from 0.55-2.75 MeV for Chang'E-1 gamma-ray spectrometer

    International Nuclear Information System (INIS)

    With a large geometrical area, the Gamma-ray spectrometer (GRS) onboard Chang'E-1 was designed to detect gamma rays from the moon. The scientific objective is to study the element information including both type and abundance by distinguishing the energy of gamma ray peak relative to elements and calculating the peak area counts. Regretfully, the cislunar spectrum of GRS was not collected. Nevertheless, we give a method to estimate the background count rate in the energy field from 0.55-2.75 MeV. A natural radioactivity count rate map in 2°×2° grids is shown after reducing the background count rate and the uncertainty of the result is discussed.

  16. Measurement of the neutron fields produced by a 62 MeV proton beam on a PMMA phantom using extended range Bonner sphere spectrometers

    International Nuclear Information System (INIS)

    The experimental characterization of the neutron fields produced as parasitic effect in medical accelerators is assuming an increased importance for either the patient protection or the facility design aspects. Medical accelerators are diverse in terms of particle type (electrons or hadrons) and energy, but the radiation fields around them have in common (provided that a given threshold energy is reached) the presence of neutrons with energy span over several orders of magnitude. Due to the large variability of neutron energy, field or dosimetry measurements in these workplaces are very complex, and in general, cannot be performed with ready-to-use commercial instruments. In spite of its poor energy resolution, the Bonner Sphere Spectrometer (BSS) is the only instrument able to simultaneously determine all spectral components in such workplaces. The energy range of this instrument is limited to Eo and 90o with respect to the beam-line. Here the ERBSS of UAB (Universidad Autonoma de Barcelona-Grup de Fisica de les Radiacions) and INFN (Istituto Nazionale di Fisica Nucleare-Laboratori Nazionali di Frascati) were exposed to characterize the 'forward' and 'sideward' proton-induced neutron fields. The use of two ERBSS characterized by different set of spheres, central detectors, and independently established and calibrated, is important for guaranteeing the robustness of the measured spectra and estimating their overall uncertainties.

  17. The spectral database Specchio: Data management, data sharing and initial processing of field spectrometer data within the Dimensions of Biodiversity project

    Science.gov (United States)

    Hueni, A.; Schweiger, A. K.

    2015-12-01

    Field spectrometry has substantially gained importance in vegetation ecology due to the increasing knowledge about causal ties between vegetation spectra and biochemical and structural plant traits. Additionally, worldwide databases enable the exchange of spectral and plant trait data and promote global research cooperation. This can be expected to further enhance the use of field spectrometers in ecological studies. However, the large amount of data collected during spectral field campaigns poses major challenges regarding data management, archiving and processing. The spectral database Specchio is designed to organize, manage, process and share spectral data and metadata. We provide an example for using Specchio based on leaf level spectra of prairie plant species collected during the 2015 field campaign of the Dimensions of Biodiversity research project, conducted at the Cedar Creek Long-Term Ecological Research site, in central Minnesota. We show how spectral data collections can be efficiently administered, organized and shared between distinct research groups and explore the capabilities of Specchio for data quality checks and initial processing steps.

  18. Tunable Reflective Spatial Heterodyne Spectrometer: A Technique for High Resolving Power, Wide Field Of View Observation Of Diffuse Emission Line Sources

    Science.gov (United States)

    Hosseini, Seyedeh Sona

    The purpose of this dissertation is to discuss the need for new technology in broadband high-resolution spectroscopy based on the emerging technique of Spatial Heterodyne Spectroscopy (SHS) and to propose new solutions that should enhance and generalize this technology to other fields. Spectroscopy is a proven tool for determining compositional and other properties of remote objects. Narrow band imaging and low resolving spectroscopic measurements provide information about composition, photochemical evolution, energy distribution and density. The extension to high resolving power provides further access to temperature, velocity, isotopic ratios, separation of blended sources, and opacity effects. In current high resolving power devices, the drawback of high-resolution spectroscopy is bound to the instrumental limitations of lower throughput, the necessity of small entrance apertures, sensitivity, field of view, and large physical instrumental size. These limitations quickly become handicapping for observation of faint and/or extended targets and for spacecraft encounters. A technique with promise for the study of faint and extended sources at high resolving power is the reflective format of the Spatial Heterodyne Spectrometer (SHS). SHS instruments are compact and naturally tailored for both high etendue (defined in section 2.2.5) and high resolving power. In contrast, to achieve similar spectral grasp, grating spectrometers require large telescopes. For reference, SHS is a cyclical interferometer that produces Fizeau fringe pattern for all other wavelengths except the tuned wavelength. The large etendue obtained by SHS instruments makes them ideal for observations of extended, low surface brightness, isolated emission line sources, while their intrinsically high spectral resolution enables one to study the dynamical and physical properties described above. This document contains four chapters. Chapter 1, introduces a class of scientific targets that formerly have

  19. Signatures for axial chromodynamics

    International Nuclear Information System (INIS)

    Within the context of basic left-right symmetry and the hypothesis of unification of weak, electromagnetic and strong forces at a mass level approximately equal to 104-106 GeV, relatively light ''mass'' axial gluons, confined or liberated, must be postulated. The authors remark that the existence of such ''light'' axial gluons supplementing the familiar vector octet preserves the successes of QCD, both for deep inelastic processes and charmonium physics. Through the characteristic spin-spin force, generated by their exchange, they may even help resolve some of the discrepancies between vector QCD predictions and charmonium physics. The main remark of this note is that if colour is liberated, not only vector but also axial-vector gluons are produced in high-energy e-e+ experiments, e.g. at PETRA and PEP, with fairly large cross-section. Distinctive decay modes of such liberated axial gluons are noted

  20. Surface nanoscale axial photonics

    OpenAIRE

    Sumetsky, M.; Fini, J. M.

    2011-01-01

    Dense photonic integration promises to revolutionize optical computing and communications. However, efforts towards this goal face unacceptable attenuation of light caused by surface roughness in microscopic devices. Here we address this problem by introducing Surface Nanoscale Axial Photonics (SNAP). The SNAP platform is based on whispering gallery modes circulating around the optical fiber surface and undergoing slow axial propagation readily described by the one-dimensional Schr\\"odinger e...

  1. Semiconductor spectrometer for radiation protection

    International Nuclear Information System (INIS)

    The radiation fields on aircraft board and for other radiation protection application are complexes they contain the particles with energies up to few hundreds MeV. Obviously, one distinguishes the components with low resp. high linear energy transfer (LET). Recently, we have acquired a new measuring instrument, MDU-LIULIN, an energy deposition spectrometer base on a Si-detector. The spectrometer was originally developed and largely tested onboard of cosmic vehicles, its sensitive element is a Si-diode. The spectrometer has been calibrated in photon, neutron and high-energy radiation reference fields (CERN). The energy deposited in the detector by a particle is analysed by a 256-channel spectrum analyser, it permits to distinguish the contribution of different types of radiation to integral dosimetry quantities. The spectrometer has been, since April 2000 used for some radiation protection applications, mostly on aircraft board. Results obtained are presented, discussed and analysed. Materials and methods. (authors)

  2. Comment on 'Consequences of phase separation on the distribution of hydrothermal fluids at ASHES vent field, axial volcano, Juan de Fuca ridge' by Christopher G. Fox

    Science.gov (United States)

    Scholl, M. A.; Ingebritsen, S. E.; Essaid, H. I.

    1993-02-01

    Fox (1990), in order to explain observations during the Axial Seamount Hydrothermal Emissions Study (ASHES), proposed a conceptual model for a two-phase subsea hydrothermal system in which steam controlled flow patterns by blocking liquid flow. An attempt is made here to demonstrate with a very general model that relative permeability contrasts by themselves do not cause spatial isolation of phases in steam/liquid water systems and that density segregation, independent of relative permeability effects, should not be ruled out as an explanation for the observations at the ASHES site. Fox replies that density segregation is probably not the only mechanism at work.

  3. Experimental test of a newly developed single-moderator, multi-detector, directional neutron spectrometer in reference monochromatic fields from 144 keV to 16.5 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Bedogni, R., E-mail: roberto.bedogni@lnf.infn.it [INFN – LNF, via E. Fermi n. 40, 00044 Frascati (Roma) (Italy); Gómez-Ros, J.M. [INFN – LNF, via E. Fermi n. 40, 00044 Frascati (Roma) (Italy); CIEMAT, Av. Complutense 40, 28040 Madrid (Spain); Pola, A.; Bortot, D. [Politecnico di Milano, Dipartimento di Energia, via La Masa 34, 20156 Milano (Italy); INFN – Milano, Via Celoria 16, 20133 Milano (Italy); Gentile, A. [INFN – LNF, via E. Fermi n. 40, 00044 Frascati (Roma) (Italy); Introini, M.V. [Politecnico di Milano, Dipartimento di Energia, via La Masa 34, 20156 Milano (Italy); INFN – Milano, Via Celoria 16, 20133 Milano (Italy); Buonomo, B. [INFN – LNF, via E. Fermi n. 40, 00044 Frascati (Roma) (Italy); Lorenzoli, M. [Politecnico di Milano, Dipartimento di Energia, via La Masa 34, 20156 Milano (Italy); INFN – Milano, Via Celoria 16, 20133 Milano (Italy); Mazzitelli, M. [INFN – LNF, via E. Fermi n. 40, 00044 Frascati (Roma) (Italy); Sacco, D. [INFN – LNF, via E. Fermi n. 40, 00044 Frascati (Roma) (Italy); INAIL – DPIA, Via di Fontana Candida n.1, 00040 Monteporzio Catone (Italy)

    2015-05-11

    A new directional neutron spectrometer called CYSP (CYlindrical SPectrometer) was developed within the NESCOFI@BTF (2011–2013) collaboration. The device, composed by seven active thermal neutron detectors located along the axis of a cylindrical moderator, was designed to simultaneously respond from the thermal domain up to hundreds of MeV neutrons. The new spectrometer condenses the performance of the Bonner Sphere Spectrometer in a single moderator; thus requiring only one exposure to determine the whole spectrum. The CYSP response matrix, determined with MCNP, has been experimentally evaluated with monochromatic reference neutron fields from 144 keV to 16.5 MeV, plus a {sup 252}Cf source, available at NPL (Teddington, UK). The results of the experiment confirmed the correctness of the response matrix within an overall uncertainty of ±2.5%. The new active spectrometer CYSP offers an innovative option for real-time monitoring of directional neutron fields as those produced in neutron beam-lines.

  4. The Axial Current in Electromagnetic Interaction

    CERN Document Server

    Cheoun, M K; Cheon, I T; Cheoun, Myung Ki; Cheon, Il-Tong

    1998-01-01

    We discussed the possibility that the charged axial currents of matter fields could be non-conserved in electromagnetic interaction at $O(e) $ order. It means that chiral symmetry is broken explicitly by electromagnetic interaction. This explicit symmetry breaking of chiral symmetry is shown to lead the mass differences between the charged and neutral particles of matter fields.

  5. Comparison of Uncalibrated Rgbvi with Spectrometer-Based Ndvi Derived from Uav Sensing Systems on Field Scale

    Science.gov (United States)

    Bareth, G.; Bolten, A.; Gnyp, M. L.; Reusch, S.; Jasper, J.

    2016-06-01

    The development of UAV-based sensing systems for agronomic applications serves the improvement of crop management. The latter is in the focus of precision agriculture which intends to optimize yield, fertilizer input, and crop protection. Besides, in some cropping systems vehicle-based sensing devices are less suitable because fields cannot be entered from certain growing stages onwards. This is true for rice, maize, sorghum, and many more crops. Consequently, UAV-based sensing approaches fill a niche of very high resolution data acquisition on the field scale in space and time. While mounting RGB digital compact cameras to low-weight UAVs (market since a decade. It was modified for this study to fit the requirements of UAV-based data acquisition. Consequently, we focus on three objectives in this contribution: (1) to evaluate the potential of the uncalibrated RGBVI for monitoring nitrogen status in winter wheat, (2) investigate the UAV-based performance of the modified Yara N-Sensor, and (3) compare the results of the two different UAV-based sensing approaches for winter wheat.

  6. Comparison of Uncalibrated Rgbvi with Spectrometer-Based Ndvi Derived from Uav Sensing Systems on Field Scale

    Science.gov (United States)

    Bareth, G.; Bolten, A.; Gnyp, M. L.; Reusch, S.; Jasper, J.

    2016-06-01

    The development of UAV-based sensing systems for agronomic applications serves the improvement of crop management. The latter is in the focus of precision agriculture which intends to optimize yield, fertilizer input, and crop protection. Besides, in some cropping systems vehicle-based sensing devices are less suitable because fields cannot be entered from certain growing stages onwards. This is true for rice, maize, sorghum, and many more crops. Consequently, UAV-based sensing approaches fill a niche of very high resolution data acquisition on the field scale in space and time. While mounting RGB digital compact cameras to low-weight UAVs (UAV platform (images which are used to compute the RGBVI and (ii) NDVI is computed from a newly modified version of the Yara N-Sensor. The latter is a well-established tractor-based hyperspectral sensor for crop management and is available on the market since a decade. It was modified for this study to fit the requirements of UAV-based data acquisition. Consequently, we focus on three objectives in this contribution: (1) to evaluate the potential of the uncalibrated RGBVI for monitoring nitrogen status in winter wheat, (2) investigate the UAV-based performance of the modified Yara N-Sensor, and (3) compare the results of the two different UAV-based sensing approaches for winter wheat.

  7. A field-deployable, chemical ionization time-of-flight mass spectrometer: application to the measurement of gas-phase organic and inorganic acids

    Directory of Open Access Journals (Sweden)

    T. H. Bertram

    2011-03-01

    Full Text Available We report a new field-deployable chemical ionization time-of-flight mass spectrometer (CI-TOFMS for the direct measurement of trace gases in the atmosphere. We apply the technique to the measurement of gas-phase inorganic and organic acids via negative-ion proton transfer, using acetate as the reagent ion. A novel high pressure interface, incorporating two RF-only quadrupoles is used to efficiently focus ions through four stages of differential pumping before analysis with a compact TOFMS. The high ion-duty cycle (>20% of the TOFMS, coupled to efficient production and transmission of ions in the high pressure interface results in a highly sensitive (>300 ions s−1 pptv−1 instrument capable of the fast measurement of atmospheric gases at trace levels. We demonstrate the efficient transfer and detection of both bare ions and ion-molecule clusters, and characterize the instrument during field measurements aboard the R/V Atlantis as part of the CalNex campaign during the spring of 2010. The in-field short-term precision is better than 5% at 1 pptv (pL/L, for 1-second averages. The detection limit (3σ, 1-second averages of the current version of the CI-TOFMS, as applied to the in situ detection of gas-phase acids, is limited by the magnitude and variability in the background determination and was determined to be 4 pptv.

  8. A field-portable membrane introduction mass spectrometer for real-time quantitation and spatial mapping of atmospheric and aqueous contaminants.

    Science.gov (United States)

    Bell, Ryan J; Davey, Nicholas G; Martinsen, Morten; Collin-Hansen, Christian; Krogh, Erik T; Gill, Christopher G

    2015-02-01

    Environmental concentrations of volatile and semivolatile organic compounds (VOC/SVOCs) can vary dramatically in time and space under the influence of environmental conditions. In an industrial setting, multiple point and diffuse sources can contribute to fugitive emissions. Assessments and monitoring programs using periodic grab sampling provide limited information, often with delay times of days or weeks. We report the development and use of a novel, portable membrane introduction mass spectrometry (MIMS) system capable of resolving and quantifying VOC and SVOCs with high spatial and temporal resolution, in the field, in real-time. An electron impact ionization cylindrical ion trap mass spectrometer modified with a capillary hollow fiber polydimethylsiloxane membrane interface was used for continuous air and water sampling. Tandem mass spectrometry and selected ion monitoring scans performed in series allowed for the quantitation of target analytes, and full scan mode was used to survey for unexpected analytes. Predeployment and in-field external calibrations were combined with a continuously infused internal standard to enable real-time quantitation and monitor instrument performance. The system was operated in a moving vehicle with internet-linked data processing and storage. Software development to integrate MIMS and relevant meta-data for visualization and geospatial presentation in Google Earth is presented. Continuous quantitation enables the capture of transient events that may be missed or under-represented by traditional grab sampling strategies. Real-time geospatial maps of chemical concentration enable adaptive sampling and in-field decision support. Sample datasets presented in this work were collected in Northern Alberta in 2010-2012. PMID:25477082

  9. Development of an ion time-of-flight spectrometer for neutron depth profiling

    Science.gov (United States)

    Cetiner, Mustafa Sacit

    signal. Without loss of generality, the secondary signal is obtained by the passage of the ion through a thin carbon foil, which produces ion-induced secondary electron emission (IISEE). The time-of-flight spectrometer physically acts as an ion/electron separator. The electrons that enter the active volume of the spectrometer are transported onto the microchannel plate detector to generate the secondary signal. The electron optics can be designed in variety of ways depending on the nature of the measurement and physical requirements. Two ion time-of-flight spectrometer designs are introduced: the parallel electric and magnetic (PEM) field spectrometer and the cross electric and magnetic (CEM) field spectrometer. The CEM field spectrometers have been extensively used in a wide range of applications where precise mass differentiation is required. The PEM field spectrometers have lately found interest in mass spectroscopy applications. The application of the PEM field spectrometer for energy measurements is a novel approach. The PEM field spectrometer used in the measurements employs axial electric and magnetic fields along the nominal direction of the incident ion. The secondary electrons are created by a thin carbon foil on the entrance disk and transported on the microchannel plate that faces the carbon foil. The initial angular distribution of the secondary electrons has virtually no effect on the transport time of the secondary electrons from the surface of the carbon foil to the electron microchannel plate detector. Therefore, the PEM field spectrometer can offer high-resolution energy measurement for relatively lower electric fields. The measurements with the PEM field spectrometer were made with the Tandem linear particle accelerator at the IBM T. J. Watson Research Center at Yorktown Heights, NY. The CEM field spectrometer developed for the thesis employs axial electric field along the nominal direction of the ion, and has perpendicular magnetic field. As the

  10. An Unbroken Axial Vector Current Conservation Law

    CERN Document Server

    Sharafiddinov, Rasulkhozha S

    2015-01-01

    The mass, energy and momentum of the neutrino of a true flavor have an axial-vector nature. As a consequence, the left-handed truly neutral neutrino in an axial-vector field of emission can be converted into a right-handed one and vice versa. This predicts the unidenticality of masses, energies and momenta of neutrinos of the different components. Recognizing such a difference in masses, energies, momenta and accepting that the left-handed axial-vector neutrino and the right-handed antineutrino of true neutrality refer to long-lived C-odd leptons, and the right-handed truly neutral neutrino and the left-handed axial-vector antineutrino are of short-lived fermions of C-oddity, we would write a new CP-even Dirac equation taking into account the flavor symmetrical axial-vector mass, energy and momentum matrices. Their presence explains the spontaneous mirror symmetry violation, confirming that an axial-vector current conservation law has never violated. They reflect the availability of a mirror Minkowski space i...

  11. A quantum cascade laser infrared spectrometer for CO2 stable isotope analysis: Field implementation at a hydrocarbon contaminated site under bio-remediation.

    Science.gov (United States)

    Guimbaud, Christophe; Noel, Cécile; Chartier, Michel; Catoire, Valéry; Blessing, Michaela; Gourry, Jean Christophe; Robert, Claude

    2016-02-01

    Real-time methods to monitor stable isotope ratios of CO2 are needed to identify biogeochemical origins of CO2 emissions from the soil-air interface. An isotope ratio infra-red spectrometer (IRIS) has been developed to measure CO2 mixing ratio with δ(13)C isotopic signature, in addition to mixing ratios of other greenhouse gases (CH4, N2O). The original aspects of the instrument as well as its precision and accuracy for the determination of the isotopic signature δ(13)C of CO2 are discussed. A first application to biodegradation of hydrocarbons is presented, tested on a hydrocarbon contaminated site under aerobic bio-treatment. CO2 flux measurements using closed chamber method is combined with the determination of the isotopic signature δ(13)C of the CO2 emission to propose a non-intrusive method to monitor in situ biodegradation of hydrocarbons. In the contaminated area, high CO2 emissions have been measured with an isotopic signature δ(13)C suggesting that CO2 comes from petroleum hydrocarbon biodegradation. This first field implementation shows that rapid and accurate measurement of isotopic signature of CO2 emissions is particularly useful in assessing the contribution of contaminant degradation to the measured CO2 efflux and is promising as a monitoring tool for aerobic bio-treatment. PMID:26969546

  12. Tests of the standard model with the spectrometer PERKEO II

    International Nuclear Information System (INIS)

    The results of measurements of the beta asymmetry A = -0.1189(12) in the decay of free neutrons are discussed. The measurements are conducted using the PERKEO II spectrometer. The neutrons are polarized by a supermirror polarizer, then pass a collimation system and enter the decay volume. In the decay volume a magnetic field (B ≅ 1 T) separates the decay neutrons: some gyrated in the direction of the magnetic field, the others in the opposite direction. The prospects for improving the experimental installation in order to refine this result and provide capabilities for measuring the weak magnetism term k and the neutrino asymmetry B are considered as well. The results obtained are used for verification of the standard model of the elementary particles and their interactions. It is shown that the neutron decay may be described as an interaction between a hadronic and a leptonic current each consisting of a vector and an axial vector part. The vector part is considered to be conserved. The axial vector part of the hadronic current is renormalized by a constant λ. The best way to find λ experimentally is to measure the beta asymmetry A in the decay of free polarized neutrons. With the result values for the other coupling constants in the same process, the neutrino asymmetry B and the electron neutrino correlation coefficient a are also fixed. A comparison of their predicted values with experimental ones tests the consistency of the theory

  13. Improvements to mass spectrometers

    International Nuclear Information System (INIS)

    This invention concerns mass spectrometers and, specifically, an ion beam analyser that facilitates the use of these spectrometers. Its object is to provide an improved apparatus for determining the desorption characteristics by field effect of a sample. It also aims to provide an improved system for carrying out sample analyses by using field effect desorption. Under the invention, facilities are added to the analyser to put out of action a part at least of the separation facilities so that the ion beam coming from the source of ions is not deflected. Detection means are located along the non deflected ion beam to detect the ions of the sample when they effectively appear and finally, actuating facilities are coupled to the out-of-action system so that the mass separation facilities may be brought back into action. This enables the operator to vary the parameters, such as the position of the source (emitter), the temperature and the electric field intensity until ions are released by the unknown sample

  14. Development of Miniature Spectrometers

    Institute of Scientific and Technical Information of China (English)

    ZHANG Zhi-guo

    2007-01-01

    Spectrometer is an essential and necessary optical element used for measuring the chemical components and content of the matter.The development of miniature spectrometers can be traced back to 1980s.The development state and different manufacturing methods of micro-spectrometers are presented.Finally,we analyze the miniaturization trend of spectrometers.Some groundwork for the scientific research is offered by introducing micro-spectrometers development.

  15. Measurement of the neutron fields produced by a 62 MeV proton beam on a PMMA phantom using extended range Bonner sphere spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Amgarou, K. [Grup de Recerca en Radiacions Ionitzants, Departament de Fisica, Universitat Autonoma de Barcelona, E-08193 Bellaterra (Spain); Bedogni, R., E-mail: roberto.bedogni@lnf.infn.it [INFN-Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Frascati, Via E. Fermi n. 40, 00044 Frascati (Italy); Domingo, C. [Grup de Recerca en Radiacions Ionitzants, Departament de Fisica, Universitat Autonoma de Barcelona, E-08193 Bellaterra (Spain); Esposito, A.; Gentile, A.; Carinci, G. [INFN-Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Frascati, Via E. Fermi n. 40, 00044 Frascati (Italy); Russo, S. [INFN-Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, via S. Sofia 44, 95123 Catania (Italy)

    2011-10-21

    The experimental characterization of the neutron fields produced as parasitic effect in medical accelerators is assuming an increased importance for either the patient protection or the facility design aspects. Medical accelerators are diverse in terms of particle type (electrons or hadrons) and energy, but the radiation fields around them have in common (provided that a given threshold energy is reached) the presence of neutrons with energy span over several orders of magnitude. Due to the large variability of neutron energy, field or dosimetry measurements in these workplaces are very complex, and in general, cannot be performed with ready-to-use commercial instruments. In spite of its poor energy resolution, the Bonner Sphere Spectrometer (BSS) is the only instrument able to simultaneously determine all spectral components in such workplaces. The energy range of this instrument is limited to E<20 MeV if only polyethylene spheres are used, but can be extended to hundreds of MeV by including metal-loaded spheres (extended range BSS, indicated with ERBSS). With the aim of providing useful data to the scientific community involved in neutron measurements at hadron therapy facilities, an ERBSS experiment was carried out at the Centro di AdroTerapia e Applicazioni Nucleari Avanzate (CATANA) of INFN-LNS (Laboratori Nazionali del Sud), where a proton beam routinely used for ophthalmic cancer treatments is available. The 62 MeV beam was directed towards a PMMA phantom, simulating the patient, and two neutron measurement points were established at 0{sup o} and 90{sup o} with respect to the beam-line. Here the ERBSS of UAB (Universidad Autonoma de Barcelona-Grup de Fisica de les Radiacions) and INFN (Istituto Nazionale di Fisica Nucleare-Laboratori Nazionali di Frascati) were exposed to characterize the 'forward' and 'sideward' proton-induced neutron fields. The use of two ERBSS characterized by different set of spheres, central detectors, and

  16. On renormalization of axial anomaly

    International Nuclear Information System (INIS)

    It is shown that multiplicative renormalization of the axial singlet current results in renormalization of the axial anomaly in all orders of perturbation theory. It is a necessary condition for the Adler - Bardeen theorem being valid. 10 refs.; 2 figs

  17. Axial compressor stability enhancement

    OpenAIRE

    Houghton, Timothy Oliver.

    2010-01-01

    Aircraft jet engines must operate in a stable manner at all times. One source of instability is compressor stall. Stall problems can be reduced by machining cavities into the compressor casing adjacent to the rotor blades. This ?casing treatment? is the focus of the present work. Two treatment configurations are tested: circumferential grooves cut into the casing above the rotor blades, and axial slots cut into the casing adjacent to the rotor blade leading edges. The performance of a single ...

  18. Green's Functions in Axial and Lorentz-type Gauges and Application to The Axial Pole Prescription and The Wilson Loop

    OpenAIRE

    Joglekar, Satish D.

    2000-01-01

    We summarize the work done in connecting Green's functions in a different classes of gauges and its applications to the problems in the axial gauges.The procedure adopted uses finite field-dependent BRS [FFBRS] transformations to connect axial and the Lorentz type gauges.These transformations preserve the vacuum expectation of gauge-invariant observables explicitly. We discuss the applications of these ideas to the axial gauge pole problem and to the preservation of the Wilson loop and the th...

  19. Pulsed-field magnetization study for Gd123 bulk HTS cooled with condensed neon for axial-gap type synchronous motor

    International Nuclear Information System (INIS)

    The closed-cycled refrigeration of neon by using a GM cryocooler has successfully provided a low-temperature pulsed-field magnetization at 38 K for field-pole Gd123 bulks in the testing rotating machine. Upon magnetization, a new split-type of armature coil, Controlled Magnetic field density Distribution Coil (CMDC) was employed. The CMDC has realized a control of magnetic field by choosing effective diameter of the vortex coil either 44 mm or 84 mm for the sample with 60 mm in diameter. The maximum trapped magnetic flux density reached over 1.3 T at 1.3 mm from the surface of bulk. 2.5 times larger flux was obtained for the field pole bulk in contrast to the liquid nitrogen cooling. The output of the motor was enhanced to 25 kW associated with a practical closed-cycle cooling without a liquid cryogen

  20. Primitive axial algebras of Jordan type

    OpenAIRE

    Hall, J I; Rehren, F; Shpectorov, S.

    2014-01-01

    An axial algebra over the field $\\mathbb F$ is a commutative algebra generated by idempotents whose adjoint action has multiplicity-free minimal polynomial. For semisimple associative algebras this leads to sums of copies of $\\mathbb F$. Here we consider the first nonassociative case, where adjoint minimal polynomials divide $(x-1)x(x-\\eta)$ for fixed $0\

  1. Formation of ordered films of axially bridged aluminum phthalocyanine [(tBu)4PcAl]2O via magnetic field-induced reaction

    International Nuclear Information System (INIS)

    The μ-(oxo)bis[tetra-tert-butylphthalocyaninato] aluminum(III) [(tBu)4PcAl]2O films with the crystallites oriented preferably in one direction were obtained via chemical transformation of tetra-tert-butylsubstituted chloroaluminum(III) phthalocyanine (tBu)4PcAlCl film upon its annealing in magnetic field. A comparative analysis of the influence of post-deposition annealing process without and under applied magnetic field of 1 T, on the orientation and morphology of (tBu)4PcAlCl and [(tBu)4PcAl]2O films, has been carried out by the methods of UV-vis, Infrared and Raman spectroscopies, XRD as well as atomic force microscopy. The formation of [(tBu)4PcAl]2O films with elongated crystallites having preferential orientation was observed upon heating of the films in magnetic field while annealing without magnetic field under the same conditions does not demonstrate any effect on the structure and morphology of these films. The reasons of the sensitivity of this reaction to the presence of such magnetic field is discussed and studied by electronic paramagnetic resonance spectroscopy

  2. Portable smartphone optical fibre spectrometer

    Science.gov (United States)

    Hossain, Md. Arafat; Canning, John; Cook, Kevin; Jamalipour, Abbas

    2015-09-01

    A low cost, optical fibre based spectrometer has been developed on a smartphone platform for field-portable spectral analysis. Light of visible wavelength is collected using a multimode optical fibre and diffracted by a low cost nanoimprinted diffraction grating. A measurement range over 300 nm span (λ = 400 to 700 nm) is obtained using the smartphone CMOS chip. The spectral resolution is Δλ ~ 0.42 nm/screen pixel. A customized Android application processed the spectra on the same platform and shares with other devices. The results compare well with commercially available spectrometer.

  3. Critical Axial Load

    Directory of Open Access Journals (Sweden)

    Walt Wells

    2008-01-01

    Full Text Available Our objective in this paper is to solve a second order differential equation for a long, simply supported column member subjected to a lateral axial load using Heun's numerical method. We will use the solution to find the critical load at which the column member will fail due to buckling. We will calculate this load using Euler's derived analytical approach for an exact solution, as well as Euler's Numerical Method. We will then compare the three calculated values to see how much they deviate from one another. During the critical load calculation, it will be necessary to calculate the moment of inertia for the column member.

  4. Time-resolved hard x-ray spectrometer

    Science.gov (United States)

    Moy, Kenneth; Cuneo, Michael; McKenna, Ian; Keenan, Thomas; Sanford, Thomas; Mock, Ray

    2006-08-01

    Wired array studies are being conducted at the SNL Z accelerator to maximize the x-ray generation for inertial confinement fusion targets and high energy density physics experiments. An integral component of these studies is the characterization of the time-resolved spectral content of the x-rays. Due to potential spatial anisotropy in the emitted radiation, it is also critical to diagnose the time-evolved spectral content in a space-resolved manner. To accomplish these two measurement goals, we developed an x-ray spectrometer using a set of high-speed detectors (silicon PIN diodes) with a collimated field-of-view that converged on a 1-cm-diameter spot at the pinch axis. Spectral discrimination is achieved by placing high Z absorbers in front of these detectors. We built two spectrometers to permit simultaneous different angular views of the emitted radiation. Spectral data have been acquired from recent Z shots for the radial and axial (polar) views. UNSPEC 1 has been adapted to analyze and unfold the measured data to reconstruct the x-ray spectrum. The unfold operator code, UFO2, is being adapted for a more comprehensive spectral unfolding treatment.

  5. The barrel muon spectrometer of the ATLAS detector has acquired its first cosmic event in a magnetic field produced by the barrel toroid magnet.

    CERN Multimedia

    2006-01-01

    A 3-D event display of a cosmic muon event, showing the path of a muon travelling through three layers of the barrel muon spectrometer. Three of the eight coils of the barrel toroid magnet can be seen in the top half of the drawing.

  6. New spectrometers based in detectors of state solid dosimetry of neutrons in pulsed fields; Nuevos espectrometros basados en detectores de estado solido para dosimetria de neutrones en campos pulsados

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Ros, J. M.; Bedogni, R.; Esposito, A.; Gentile, A.; Introini, M. V.; Moraleda, M.; Pola, A.; Romero, A. M.

    2013-07-01

    Measurement of neutron Spectra varying with time (pulsed fields) is particularly complex since its determination should be done with a single exposure. This communication presents the main results obtained during the last two years jointly between INFN LNF, Politecnico di Milano and CIEMAT, in the framework of projects NESCOFI@BTF (INFN, Commissione Scientifica Nazionale 5, Italy) and AIC-D-2011 - 0717 (MINECO, Spain) that have resulted in the development of two spectrometers, one spherical and other cylindrical, usable for isotropic fields and do collimated, respectively in the energy range from heat up to 100-200 MeV neutrons. (Author)

  7. 21 CFR 862.2860 - Mass spectrometer for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Mass spectrometer for clinical use. 862.2860... Instruments § 862.2860 Mass spectrometer for clinical use. (a) Identification. A mass spectrometer for... by means of an electrical and magnetic field according to their mass. (b) Classification. Class...

  8. Investigation of Unsteady Flow Field in a Low-Speed One and a Half Stage Axial Compressor. Part 2; Effects of Tip Gap Size On the Tip Clearance Flow Structure at Near Stall Operation

    Science.gov (United States)

    Hah, Chunill; Hathaway, Michael; Katz, Joseph

    2014-01-01

    The primary focus of this paper is to investigate the effect of rotor tip gap size on how the rotor unsteady tip clearance flow structure changes in a low speed one and half stage axial compressor at near stall operation (for example, where maximum pressure rise is obtained). A Large Eddy Simulation (LES) is applied to calculate the unsteady flow field at this flow condition with both a small and a large tip gaps. The numerically obtained flow fields at the small clearance matches fairly well with the available initial measurements obtained at the Johns Hopkins University with 3-D unsteady PIV in an index-matched test facility which renders the compressor blades and casing optically transparent. With this setup, the unsteady velocity field in the entire flow domain, including the flow inside the tip gap, can be measured. The numerical results are also compared with previously published measurements in a low speed single stage compressor (Maerz et al. [2002]). The current study shows that, with the smaller rotor tip gap, the tip clearance vortex moves to the leading edge plane at near stall operating condition, creating a nearly circumferentially aligned vortex that persists around the entire rotor. On the other hand, with a large tip gap, the clearance vortex stays inside the blade passage at near stall operation. With the large tip gap, flow instability and related large pressure fluctuation at the leading edge are observed in this one and a half stage compressor. Detailed examination of the unsteady flow structure in this compressor stage reveals that the flow instability is due to shed vortices near the leading edge, and not due to a three-dimensional separation vortex originating from the suction side of the blade, which is commonly referred to during a spike-type stall inception. The entire tip clearance flow is highly unsteady. Many vortex structures in the tip clearance flow, including the sheet vortex system near the casing, interact with each other. The

  9. Axial skeletal CT densitometry

    International Nuclear Information System (INIS)

    Since the discovery of the Roentgen ray a precise and accurate assessment of bone mineral content has been a challenge to many investigators. A number of methods have been developed but no one satisfied. Considering its technical possibilities computed tomography is very promising in determination of bone mineral content (BMC). The new modality enables BMC estimations in the axial skeletal trabecular bone. CT densitometry can be performed on a normal commercially available third generation whole body CT scanner. No dedicated device in a special clinical set-up is necessary. In this study 106 patients, most of them clinically suspected of osteoporosis, were examined. The new method CT densitometry has been evaluated. The results have been correlated to alternative BMC determination methods. (Auth.)

  10. Plasma measurements with the TMX-U E parallel to B end-loss-ion spectrometers

    International Nuclear Information System (INIS)

    Two E parallel to B end-loss-ion spectrometers (ELIS) are now making plasma measurements on Tandem Mirror Experiment-Upgrade (TMX-U). One instrument is mounted on each end of this open-ended tandem-mirror machine. These spectrometers observe plasma losses along magnetic-field lines. They operate reliably and with a minimum of attention during an experimental run. Their data, which are quickly acquired and analyzed, help guide the experimental sequence. The parallel electric and magnetic fields separate the end-loss ions according to mass (D+ and H+) and energy. Each spectrometer detects ions with an array of 128 flat collector plates that are made from copper-coated G10 epoxy fiberglass, normally used for printed-circuit boards. The ELIS diagnostic system produces a wealth of experimental information, including data on peak plasma potential, central-cell ion temperature, potentials in the thermal-barrier region, axial confinement and ion-end-loss plugging, energetic-electron losses, and hydrogen/deuterium concentrations. 6 refs., 5 figs

  11. Tests of a large air-core superconducting solenoid as a nuclear-reaction-product spectrometer

    International Nuclear Information System (INIS)

    An air-core superconducting solenoid, with a diameter of 0.2 m and a length of 0.4 m, has been configured for use as a heavy-ion reaction-product spectrometer (E/A≤5 MeV/u) near θ = 0 0. The spectrometer has a large solid angle (10--35 msr) and properties suitable for time-of-flight measurements with flight paths approx. > 2 m. The performance of the spectrometer was established using α-particle sources and nuclear-reaction products from heavy-ion collisions. The characteristics of air-core magnets are compared to those of steel-yoke magnets. The simplicity and ease of operation of the air-core magnet, without significant problems from the (axial) fringe fields, suggests that larger air-core magnets with dΩ≥20 msr and capable of focusing ions with E/A≥30 MeV/u are feasible. Other applications of solenoids and combinations of solenoids with radial electric-field lenses (ELCO lenses) are also discussed, including designs which focus more than one charge state simultaneously

  12. Degenerate seaweed to tilted dendrite transition and their growth dynamics in directional solidification of non-axially oriented crystals: a phase-field study.

    Science.gov (United States)

    Xing, Hui; Dong, Xianglei; Wu, Hongjing; Hao, Guanhua; Wang, Jianyuan; Chen, Changle; Jin, Kexin

    2016-01-01

    We report the results of a phase-field study of degenerate seaweed to tilted dendrite transition and their growth dynamics during directional solidification of a binary alloy. Morphological selection maps in the planes of (G, Vp) and (ε4, Vp) show that lower pulling velocity, weaker anisotropic strength and higher thermal gradient can enhance the formation of the degenerate seaweed. The tip undercooling shows oscillations in seaweed growth, but it keeps at a constant value in dendritic growth. The M-S instability on the tips and the surface tension anisotropy of the solid-liquid interface are responsible for the formation of the degenerate seaweed. It is evidenced that the place where the interfacial instability occurs determines the morphological transition. The transient transition from degenerate seaweed to tilted dendrite shows that dendrites are dynamically preferred over seaweed. For the tilted dendritic arrays with a large tilted angle, primary spacing is investigated by comparing predicted results with the classical scaling power law, and the growth direction is found to be less sensitive to the pulling velocity and the primary spacing. Furthermore, the effect of the initial interface wavelength on the morphological transition is investigated to perform the history dependence of morphological selection. PMID:27210816

  13. Compact field programmable gate array (FPGA)-based multi-axial interferometer for simultaneous tilt and distance measurement in the sub-nanometre range

    International Nuclear Information System (INIS)

    Quantitative determination of microstructure and nanostructure properties is essential in research, development and in control of the production process. In instruments for dimensional nanometrology the positioning stage is the key component, since the characteristics of the position acquisition and control determine directly the achievable precision of the complete system. Compact commercial positioning systems usually employ capacitive or inductive position sensors. Both technologies not only offer a resolution in the nanometre range, but also require a (periodic) calibration. To achieve traceable measurements, interferometric sensors need to be implemented into the metrology system. However, currently available commercial interferometers turned out to be too large to be installed in miniature positioning stages easily. Therefore, a new highly compact interferometer to allow for traceability and an uncertainty in the Ångstrom range was developed. One of its first applications will be the new metrological low-noise atomic force microscope at the Physikalisch-Technische Bundesanstalt. The new interferometer is based on a modified homodyne Twyman–Green interferometer concept. It uses a novel signal processing approach based on a field programmable gate array, whereby a spatial interferogram is acquired by a high-speed CMOS line sensor and transformed into its frequency spectrum through a discrete Fourier transform. The spectral representation is analyzed for its major components; the phase information bears a direct connection to the displacement of the positioning unit. Furthermore, a possible stage tilt during the scan gives rise to a shift of the peak magnitude in the frequency spectrum. In addition, the developed system proved to be easily extendable to multiple axes by superimposing multiple interferograms on a single line sensor

  14. Axial anomaly in nonrenormalizable theories

    International Nuclear Information System (INIS)

    The anomaly for the axial current in nonrenormalizable theories with electromagnetic coupling is considered. The spinor electrodynamics with Pauli term is examined in detail using the Feynman graph technique and the point-splitting method. The same finite value for the axial anomaly emerges. (author)

  15. How different is the time-averaged field from that of a geocentric axial dipole ? Making the best of paleomagnetic directional data using the statistical Giant Gaussian Process approach.

    Science.gov (United States)

    Hulot, G.; Khokhlov, A.; Johnson, C. L.

    2012-12-01

    It is well known that the geometry of the recent time-averaged paleomagnetic field (TAF) is very close to that of a geocentric axial dipole (GAD). Yet, numerous numerical dynamo simulations show that some departures from such a simple geometry is to be expected, not least because of the heterogeneous thermal core-mantle boundary conditions that the convecting mantle imposes on the geodynamo. Indeed, many TAF models recovered from averaging lava flow paleomagnetic directional data (the most numerous and reliable of all data) would suggest this is the case. However, assessing the significance of such minor departures from the GAD is particularly challenging, because non-linear directional data are sensitive not only to the time-averaged component of the field, but also to its time fluctuating component, known as the paleosecular variation (PSV). This means that in addition to data errors, PSV also must be taken into account when assessing any lava flow directional data based claims of departures of the TAF from the GAD. Furthermore, because of limited age information for these data , it is necessary to assess departures from the GAD by resorting to a statistical approach. We report recent progress using an approach we have suggested and further developed (Khokhlov et al., Geophysical Journal International, 2001, 2006) to test the compatibility of combined time-averaged (TAF) and paleosecular variation (PSV) field models, against any lava flow paleomagnetic database, asssuming that these TAF and PSV models are defined within the Giant Gaussian Process statistical framework. In particular we will show how sensitive statistical measures of the compatibility of a combined set of TAF and PSV models with a given directional database can be defined. These measures can be used to test published TAF and PSV models with updated 0-5 Ma lava flow paleomagnetic data sets. They also lay the groundwork for designing inverse methods better suited to seek the minimum required

  16. Extra-axial brain tumors.

    Science.gov (United States)

    Rapalino, Otto; Smirniotopoulos, James G

    2016-01-01

    Extra-axial brain tumors are the most common adult intracranial neoplasms and encompass a broad spectrum of pathologic subtypes. Meningiomas are the most common extra-axial brain tumor (approximately one-third of all intracranial neoplasms) and typically present as slowly growing dural-based masses. Benign meningiomas are very common, and may occasionally be difficult to differentiate from more aggressive subtypes (i.e., atypical or malignant varieties) or other dural-based masses with more aggressive biologic behavior (e.g., hemangiopericytoma or dural-based metastases). Many neoplasms that typically affect the brain parenchyma (intra-axial), such as gliomas, may also present with primary or secondary extra-axial involvement. This chapter provides a general and concise overview of the common types of extra-axial tumors and their typical imaging features. PMID:27432671

  17. Axial Patterning in Hydra

    Science.gov (United States)

    Bode, Hans R.

    2009-01-01

    Morphogen gradients play an important role in pattern formation during early stages of embryonic development in many bilaterians. In an adult hydra, axial patterning processes are constantly active because of the tissue dynamics in the adult. These processes include an organizer region in the head, which continuously produces and transmits two signals that are distributed in gradients down the body column. One signal sets up and maintains the head activation gradient, which is a morphogenetic gradient. This gradient confers the capacity of head formation on tissue of the body column, which takes place during bud formation, hydra's mode of asexual reproduction, as well as during head regeneration following bisection of the animal anywhere along the body column. The other signal sets up the head inhibition gradient, which prevents head formation, thereby restricting bud formation to the lower part of the body column in an adult hydra. Little is known about the molecular basis of the two gradients. In contrast, the canonical Wnt pathway plays a central role in setting up and maintaining the head organizer. PMID:20066073

  18. An Unbroken Axial-Vector Current Conservation Law

    Science.gov (United States)

    Sharafiddinov, Rasulkhozha S.

    2016-04-01

    The mass, energy and momentum of the neutrino of a true flavor have an axial-vector nature. As a consequence, the left-handed truly neutral neutrino in an axial-vector field of emission can be converted into a right-handed one and vice versa. This predicts the unidenticality of masses, energies and momenta of neutrinos of the different components. Recognizing such a difference in masses, energies, momenta and accepting that the left-handed axial-vector neutrino and the right-handed antineutrino of true neutrality refer to long-lived C-odd leptons, and the right-handed truly neutral neutrino and the left-handed axial-vector antineutrino are of short-lived fermions of C-oddity, we would write a new CP-even Dirac equation taking into account the flavor symmetrical axial-vector mass, energy and momentum matrices. Their presence explains the spontaneous mirror symmetry violation, confirming that an axial-vector current conservation law has never violated. They reflect the availability of a mirror Minkowski space in which a neutrino is characterized by left as well as by right space-time coordinates. Therefore, it is not surprising that whatever the main purposes experiments about a quasielastic axial-vector mass say in favor of an axial-vector mirror Minkowski space-time.

  19. Aerosol mobility size spectrometer

    Science.gov (United States)

    Wang, Jian; Kulkarni, Pramod

    2007-11-20

    A device for measuring aerosol size distribution within a sample containing aerosol particles. The device generally includes a spectrometer housing defining an interior chamber and a camera for recording aerosol size streams exiting the chamber. The housing includes an inlet for introducing a flow medium into the chamber in a flow direction, an aerosol injection port adjacent the inlet for introducing a charged aerosol sample into the chamber, a separation section for applying an electric field to the aerosol sample across the flow direction and an outlet opposite the inlet. In the separation section, the aerosol sample becomes entrained in the flow medium and the aerosol particles within the aerosol sample are separated by size into a plurality of aerosol flow streams under the influence of the electric field. The camera is disposed adjacent the housing outlet for optically detecting a relative position of at least one aerosol flow stream exiting the outlet and for optically detecting the number of aerosol particles within the at least one aerosol flow stream.

  20. Computer-controlled neutron spectrometer SV 22

    International Nuclear Information System (INIS)

    The neutron spectrometer SV22 is a combined time of flight and back scattering spectrometer. It is located at the tangential beam tube TAN2 of the research reactor FRJ2 DIDO at Kernforschungsanlage Juelich (West-Germany). Both versions are described in their hardware layout. The neutron optical characteristics of the already functioning time of flight spectrometer are summarized. Selected experiments show some possible fields for further research with this instrument. Experimental data for the backscattering version is not yet available. The features of the operating system RSX11M are explained. Examples show the use of indirect command files in control of the experiment. (orig.)

  1. 盘式无铁心永磁同步发电机3D电磁场分析%3D Electromagnetic Field Analysis of Axial Flux Coreless Permanent Magnet Synchronous Generator

    Institute of Scientific and Technical Information of China (English)

    罗玲; 李丹; 吕晓威; 王震

    2012-01-01

    According to the special structure and complex electromagnetic field distribution of axial flux coreless permanent magnet synchronous generator, a 3D prototype model was established and its boundary conditions was set for solving by using electromagnetic finite element simulation software MagNet. No-load air-gap magnetic field was analyzed by using 3D static solver and no-load back-electromotive force at different speed was calculated by using 3D transient with motion solver. Finally, no-load characteristic of the prototype generator was tested. The test results show that the simulation model is reasonable and the analysis method is effective.%针对盘式无铁心永磁同步风力发电机结构的特殊性及其电磁场分布的复杂性,采用电磁场有限元分析软件MagNet对一台样机进行了3D建模;设置了求解所需的边界条件;利用静态求解器得到了磁场分布规律;通过动态求解器计算了不同转速下的空载电压,并绘制了样机的空载特性曲线;最后通过空载试验验证了仿真模型的合理性及计算方法的正确性.

  2. FINITE ELEMENT ANALYSIS OF AXIAL FEED BAR ROLLING

    Institute of Scientific and Technical Information of China (English)

    C.G. Xu; G.H. Liu; G.S. Ren; Z. Shen; C.P. Ma; W. W. Ren

    2007-01-01

    A flexible technique of hot working of bars by axial feed rolling was introduced. The processdeformation, strain field, stress field, and temperature field of the parts are analyzed by finite elementmethod (FEM)-simulation software DEFORM-3D. The material flow rule and tool load have beeninvestigated.

  3. Characterization of Multiflux Axial Compressors

    International Nuclear Information System (INIS)

    In the present work the results of analytical models of performance are compared with experimental data acquired in the multi flux axial compressor test facility, built in The Pilcaniyeu Technological Complex for the SIGMA project.We describe the experimental circuit and the data of the dispersion inside the axial compressor obtained using a tracer gas through one of the annular inlets.The attained results can be used to validate the design code for the multi flux axial compressors and SIGMA industrial plant

  4. Axial gap rotating electrical machine

    Energy Technology Data Exchange (ETDEWEB)

    None

    2016-02-23

    Direct drive rotating electrical machines with axial air gaps are disclosed. In these machines, a rotor ring and stator ring define an axial air gap between them. Sets of gap-maintaining rolling supports bear between the rotor ring and the stator ring at their peripheries to maintain the axial air gap. Also disclosed are wind turbines using these generators, and structures and methods for mounting direct drive rotating electrical generators to the hubs of wind turbines. In particular, the rotor ring of the generator may be carried directly by the hub of a wind turbine to rotate relative to a shaft without being mounted directly to the shaft.

  5. A Spectrometer Based on Diffractive Lens

    Institute of Scientific and Technical Information of China (English)

    WANG Daoyi; YAN Yingbai; JIN Guofan; WU Minxian

    2001-01-01

    A novel spectrometer is designed based on diffractive lens. It is essentially a flat field spectrometer. All the focal points are along the optical axis. Besides, all the asymmetrical aberrations vanish in our mounting. Thus low aberration can be obtained. In this article a diffractive lens is modeled as a special grating and analyzed by using a grating-based method. And a stigmatic point is introduced to reduce the aberrations.

  6. The neutron decay retardation spectrometer aSPECT: Electromagnetic design and systematic effects

    International Nuclear Information System (INIS)

    The apparatus described here, aSPECT, will be used for a measurement of the neutrino-electron angular correlation coefficient ain the decay of free neutrons. The idea of the aSPECT spectrometer is to measure the integrated proton energy spectrum very accurately using an energy filter by electrostatic retardation and magnetic adiabatic collimation. The main ideas of the spectrometer are presented, followed by an explanation of the adiabatic transmission function. Details of the superconducting coil and of the electrode system are given, as well as a discussion of the most important systematic effects: magnetic field and electrostatic potential inhomogeneities, deviation from adiabatic motion, scattering in the residual gas, background, Doppler effect, edge effect, and detector efficiency. Using this spectrometer, the parameter ais planned to be measured with an absolute experimental uncertainty of δa∼3.10-4, from which the axial vector to vector coupling constant ratio λ can be determined with an accuracy of δλ ∼0.001. (orig.)

  7. Microwave axial dielectric properties of carbon fiber

    Science.gov (United States)

    Hong, Wen; Xiao, Peng; Luo, Heng; Li, Zhuan

    2015-10-01

    Randomly distributed carbon fibers (CFs) reinforced epoxy resin composites are prepared by the pouring method, the dielectric properties of CF composites with different fiber content and length have been performed in the frequency range from 8.2 to 12.4 GHz. The complex permittivity of the composite increases with the fiber length, which is attributed to the decrease of depolarization field, and increases with the volume fraction, which is attributed to the increase of polarization. A formula, based on the theory of Reynolds-Hugh, is proposed to calculate the effective permittivity of CF composites, and validated by the experiments. The proposed formula is further applied to derive the axial permittivity of CF and analyze the effect of fiber length on the axial permittivity.

  8. Direct optical nanoscopy with axially localized detection

    CERN Document Server

    Bourg, N; Dupuis, G; Barroca, T; Bon, P; Lécart, S; Fort, E; Lévêque-Fort, S

    2014-01-01

    Evanescent light excitation is widely used in super-resolution fluorescence microscopy to confine light and reduce background noise. Herein we propose a method of exploiting evanescent light in the context of emission. When a fluorophore is located in close proximity to a medium with a higher refractive index, its near-field component is converted into light that propagates beyond the critical angle. This so-called Supercritical Angle Fluorescence (SAF) can be captured using a hig-NA objective and used to determine the axial position of the fluorophore with nanometer precision. We introduce a new technique for 3D nanoscopy that combines direct STochastic Optical Reconstruction Microscopy (dSTORM) imaging with dedicated detection of SAF emission. We demonstrate that our approach of a Direct Optical Nanoscopy with Axially Localized Detection (DONALD) yields a typical isotropic 3D localization precision of 20 nm.

  9. Wide swath imaging spectrometer utilizing a multi-modular design

    Science.gov (United States)

    Chrisp, Michael P.

    2010-10-05

    A wide swath imaging spectrometer utilizing an array of individual spectrometer modules in the telescope focal plane to provide an extended field of view. The spectrometer modules with their individual detectors are arranged so that their slits overlap with motion on the scene providing contiguous spatial coverage. The number of modules can be varied to take full advantage of the field of view available from the telescope.

  10. Temporal dispersion of a spectrometer.

    Science.gov (United States)

    Visco, A; Drake, R P; Froula, D H; Glenzer, S H; Pollock, B B

    2008-10-01

    The temporal dispersion of an optical spectrometer has been characterized for a variety of conditions related to optical diagnostics to be fielded at the National Ignition Facility (e.g., full-aperture backscatter station, Thomson scattering). Significant time smear is introduced into these systems by the path length difference through the spectrometer. The temporal resolution is shown to depend only on the order of the grating, wavelength, and the number of grooves illuminated. To enhance the temporal resolution, the spectral gratings can be masked limiting the number of grooves illuminated. Experiments have been conducted to verify these calculations. The size and shape of masks are investigated and correlated with the exact shape of the temporal instrument function, which is required when interpreting temporally resolved data. The experiments used a 300 fs laser pulse and a picosecond optical streak camera to determine the temporal dispersion. This was done for multiple spectral orders, gratings, and optical masks. PMID:19044687

  11. Temporal Dispersion of a Spectrometer

    International Nuclear Information System (INIS)

    The temporal dispersion of an optical spectrometer has been characterized for a variety of conditions related to optical diagnostics to be fielded at the National Ignition Facility (e.g., Full-Aperture Backscatter Station, Thomson Scattering). Significant time smear is introduced into these systems by the path length difference through the spectrometer. The temporal resolution can be calculated to depend only on the order of the grating, wavelength, and the number of grooves illuminated. To enhance the temporal dispersion, the spectral gratings can be masked limiting the number of grooves illuminated. Experiments have been conducted to verify these calculations. The size and shape of masks are investigated and correlated to the exact shape of the temporal instrument function, which is required when interpreting temporally resolved data. The experiments used a 300fs laser pulse and a picosecond optical streak camera to determine the temporal dispersion. This was done for multiple spectral orders, gratings, and optical masks

  12. Development of cold neutron spectrometers

    International Nuclear Information System (INIS)

    □ Cold Neutron Triple Axsis Spectrometer (Cold-TAS) Development Ο Fabrication and Installation of the Major Cold-TAS Components Ο Performance Test of the Cold-TAS □ Cold Neutron Time-of-Flight Spectrometer(DC-TOF) Development Ο Fabrication of the Major DC-TOF Components Ο Development DC-TOF Data Reduction Software □ Expected Contribution The two world-class inelastic neutron scattering instruments measure atomic or molecular scale dynamics of meV energy range. This unprecedented measurement capability in the country will enable domestic and international scientists to observe new phenomena in their materials research to obtain world class results. Especially those who work in the fields of magnetic properties of superconductors and multiferroics, molecular dynamics, etc. will get more benefit from these two instruments

  13. Handheld spectrometers: the state of the art

    Science.gov (United States)

    Crocombe, Richard A.

    2013-05-01

    "Small" spectrometers fall into three broad classes: small versions of laboratory instruments, providing data, subsequently processed on a PC; dedicated analyzers, providing actionable information to an individual operator; and process analyzers, providing quantitative or semi-quantitative information to a process controller. The emphasis of this paper is on handheld dedicated analyzers. Many spectrometers have historically been large, possible fragile, expensive and complicated to use. The challenge over the last dozen years, as instruments have moved into the field, has been to make spectrometers smaller, affordable, rugged, easy-to-use, but most of all capable of delivering actionable results. Actionable results can dramatically improve the efficiency of a testing process and transform the way business is done. There are several keys to this handheld spectrometer revolution. Consumer electronics has given us powerful mobile platforms, compact batteries, clearly visible displays, new user interfaces, etc., while telecomm has revolutionized miniature optics, sources and detectors. While these technologies enable miniature spectrometers themselves, actionable information has demanded the development of rugged algorithms for material confirmation, unknown identification, mixture analysis and detection of suspicious materials in unknown matrices. These algorithms are far more sophisticated than the `correlation' or `dot-product' methods commonly used in benchtop instruments. Finally, continuing consumer electronics advances now enable many more technologies to be incorporated into handheld spectrometers, including Bluetooth, wireless, WiFi, GPS, cameras and bar code readers, and the continued size shrinkage of spectrometer `engines' leads to the prospect of dual technology or `hyphenated' handheld instruments.

  14. Monte Carlo simulation of a Bonner sphere spectrometer for application to the determination of neutron field in the Experimental Advanced Superconducting Tokamak experimental hall.

    Science.gov (United States)

    Hu, Z M; Xie, X F; Chen, Z J; Peng, X Y; Du, T F; Cui, Z Q; Ge, L J; Li, T; Yuan, X; Zhang, X; Hu, L Q; Zhong, G Q; Lin, S Y; Wan, B N; Gorini, G; Li, X Q; Zhang, G H; Chen, J X; Fan, T S

    2014-11-01

    To assess the neutron energy spectra and the neutron dose for different positions around the Experimental Advanced Superconducting Tokamak (EAST) device, a Bonner Sphere Spectrometer (BSS) was developed at Peking University, with totally nine polyethylene spheres and a SP9 (3)He counter. The response functions of the BSS were calculated by the Monte Carlo codes MCNP and GEANT4 with dedicated models, and good agreement was found between these two codes. A feasibility study was carried out with a simulated neutron energy spectrum around EAST, and the simulated "experimental" result of each sphere was obtained by calculating the response with MCNP, which used the simulated neutron energy spectrum as the input spectrum. With the deconvolution of the "experimental" measurement, the neutron energy spectrum was retrieved and compared with the preset one. Good consistence was found which offers confidence for the application of the BSS system for dose and spectrum measurements around a fusion device. PMID:25430324

  15. 2D-particle image velocimetry measurement for internal flow field of axial flow pump%轴流泵内部流场的二维粒子成像测速试验

    Institute of Scientific and Technical Information of China (English)

    张华; 施卫东; 陈斌; 张德胜; 胡啟祥

    2013-01-01

    To investigate the flow field distribution at the regions of the impeller and guide vane inlet and outlet under condition of 0.8Qopt, the axial flow pump with ns=700 was selected for model scaling and structural modification, from which we could get a test bed suitable for a 2D-PIV internal flow field test. Structural modifications included: the conventional metal material was replaced with transparent organic glass material to achieve the purpose of internal visualization;the conventional conical diffuser vane was designed into cylindrical shape to reduce the complexity of optical refraction;the runner chamber was merged with a guide vane casing to form as a whole to eliminate the occlusion of the flange to an internal flow field between the region of impeller and diffuser vane;the bearing within the diffuser vane was moved backward and rib plates were installed to make the load transfer to foundation smoothly. Based on the above methods, an experiment pump section was modified successfully, and the efficiency of the experimental pump reached 73.79%, which was close to that of the prototype pump. It was indicated that less damage occurred to the original flow field with structural modification. During the PIV measurement, the shaft encoder and synchronizer were used for better synchronous effect. Meanwhile, an ideal experimental result was obtained by using organic glass hollow spheres as tracer particles, and a new calibration method. As shown in the original PIV images, the particle distribution was homogeneous with most particles appearing to be micro-exposure, which meant an ideal experiment effect. From the analysis of the experimental result, it was indicated that, owing to the effect of the tip leakage flow at the 0.8Qopt operating point, the inflow at the rim of an impeller leading edge deflects to the hub side, but the whole flow field is evenly distributed on the front section of an impeller; a clockwise vortex with an outer diameter larger than the hub

  16. The SAGE spectrometer

    International Nuclear Information System (INIS)

    The SAGE spectrometer has been constructed for in-beam nuclear structure studies. SAGE combines a Ge-detector array and an electron spectrometer for detection of γ-rays and internal conversion electrons, respectively, and allows simultaneous observation of both electrons and γ-rays emitted from excited nuclei. SAGE is set up in the Accelerator Laboratory of the University of Jyvaeskylae and works in conjunction with the RITU gas-filled recoil separator and the GREAT focal-plane spectrometer allowing the use of the recoil-decay tagging method. (orig.)

  17. The SAGE spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Pakarinen, J.; Papadakis, P. [University of Liverpool, Department of Physics, Oliver Lodge Laboratory, Liverpool (United Kingdom); University of Jyvaeskylae, Department of Physics, Jyvaeskylae (Finland); Sorri, J.; Greenlees, P.T.; Jones, P.; Julin, R.; Konki, J.; Rahkila, P.; Sandzelius, M. [University of Jyvaeskylae, Department of Physics, Jyvaeskylae (Finland); Herzberg, R.D.; Butler, P.A.; Cox, D.M.; Cresswell, J.R.; Mistry, A.; Page, R.D.; Parr, E.; Sampson, J.; Seddon, D.A.; Thornhill, J.; Wells, D. [University of Liverpool, Department of Physics, Oliver Lodge Laboratory, Liverpool (United Kingdom); Coleman-Smith, P.J.; Lazarus, I.H.; Letts, S.C.; Pucknell, V.F.E.; Simpson, J. [STFC Daresbury Laboratory, Warrington (United Kingdom)

    2014-03-15

    The SAGE spectrometer has been constructed for in-beam nuclear structure studies. SAGE combines a Ge-detector array and an electron spectrometer for detection of γ-rays and internal conversion electrons, respectively, and allows simultaneous observation of both electrons and γ-rays emitted from excited nuclei. SAGE is set up in the Accelerator Laboratory of the University of Jyvaeskylae and works in conjunction with the RITU gas-filled recoil separator and the GREAT focal-plane spectrometer allowing the use of the recoil-decay tagging method. (orig.)

  18. Application of the wavelet transforms on axial strain calculation in ultrasound elastography

    Institute of Scientific and Technical Information of China (English)

    LUO Jianwen; BAI Jing; SHAO Jinhua

    2006-01-01

    In ultrasound elastography, the axial strain distribution within biological tissues is calculated as the numerical derivative (differentiation) of the estimated axial displacement field. Unfortunately, the numerical derivative is unstable because it can greatly amplify the noises, especially at high frequencies. This work focuses on the axial strain calculation from the estimated axial displacements using wavelet transforms (WTs), including continuous wavelet transforms (CWTs) and discrete wavelet transforms (DWTs). The feasibility of the WT-based method using the quadratic spline function is verified by computer simulations and some phantom data. Results indicate that the WT-based method can effectively reduce the noise amplification in axial strain calculation.

  19. Commissioning Measurements of the KATRIN Main Spectrometer

    Science.gov (United States)

    Wierman, Kevin; Katrin Collaboration

    2013-10-01

    Beginning in May 2013, the KArlsruhe TRItium Neutrino experiment (KATRIN) collaboration began measurements to commission the 10-m diameter main spectrometer. KATRIN utilizes the spectrometer to provide magnetic adiabatic collimation and electrostatic filtering designed to analyze the tritium beta decay spectrum for contributions from the neutrino mass. In order to achieve an order-of-magnitude improvement on previous neutrino mass experiments the desired sensitivity of the apparatus must be 200 meV in the decay endpoint region. Goals of the recent measurements include identification and reduction of backgrounds and determination of the spectrometer transfer function. Backgrounds have been probed by utilizing electromagnetic field configurations to explore decays in the spectrometer, Penning traps and field emission. A 148-pixel PIN diode array is employed to detect particles exiting the spectrometer, which permits angular and radial distributions of particles to be analyzed. This has allowed for high precision comparison between measurements and simulations of expected backgrounds to be investigated in order to commission the spectrometer. This work is supported by grants from the DOE Office of Nuclear Physics and the Helmholtz Association.

  20. Digital positron annihilation spectrometer

    International Nuclear Information System (INIS)

    With the high speed development of digital signal process, the technique of the digitization and processing of signals was applied in the domain of a broad class of nuclear technique. The development of digital positron lifetime spectrometer (DPLS) is more promising than the conventional positron lifetime spectrometer equipped with nuclear instrument modules. And digital lifetime spectrometer has many advantages, such as low noise, long term stability, flexible online or offline digital processing, simple setup, low expense, easy to setting, and more physical information. Digital constant fraction discrimination is for timing. And a new method of optimizing energy windows setting for digital positron lifetime spectrometer is also developed employing the simulated annealing for the convenient use. The time resolution is 220ps and the count rate is 200cps. (authors)

  1. Numerical simulation of an axial blood pump.

    Science.gov (United States)

    Chua, Leok Poh; Su, Boyang; Lim, Tau Meng; Zhou, Tongming

    2007-07-01

    The axial blood pump with a magnetically suspended impeller is superior to other artificial blood pumps because of its small size. In this article, the distributions of velocity, path line, pressure, and shear stress in the straightener, the rotor, and the diffuser of the axial blood pump, as well as the gap zone were obtained using the commercial software, Fluent (version 6.2). The main focus was on the flow field of the blood pump. The numerical results showed that the axial blood pump could produce 5.14 L/min of blood at 100 mm Hg through the outlet when rotating at 11,000 rpm. However, there was a leakage flow of 1.06 L/min in the gap between the rotor cylinder and the pump housing, and thus the overall flow rate the impeller could generate was 6.2 L/min. The numerical results showed that 75% of the scalar shear stresses (SSs) were less than 250 Pa, and 10% were higher than 500 Pa within the whole pump. The high SS region appeared around the blade tip where a large variation of velocity direction and magnitude was found, which might be due to the steep angle variation at the blade tip. Because the exposure time of the blood cell at the high SS region within the pump was relatively short, it might not cause serious damage to the blood cells, but the improvement of blade profile should be considered in the future design of the axial pump. PMID:17584481

  2. Fluid-Field Analysis of Impeller, Traditional Typical Three-Bl ade and JH-Type New Axial-Flow Impeller%推进桨、45°三叶折叶桨及新型轴流式桨的流场分析

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    对推进桨45°三叶折叶桨及新型扭弯轴流式搅拌桨 ——JH 桨的三维流场进行了激光测速实验,结果分析表明,45°三叶折叶桨其轴向流场分布不均匀 ,而是“W”形,其周向速度随半径成正比,易于打漩,径向速度随半径增加较快。说明45 °三叶折叶桨是以轴向流为主伴有一定径向流场的一种桨型;推进桨轴向速度流场均匀,但 随着离桨距离的增加其均匀性下降,且轴线附近存在有低速区。其径向速度虽然在桨径范围 内较小,但在桨径外仍有一定值。其周向流场分布较均匀,说明推进桨也非“纯”轴流式桨 ;JH桨轴向流场均匀,随着离桨距离的增加其衰减速度减慢,其径向速度分布均匀,且较 小 ,而周向速度在桨径以外迅速衰减,并随离桨距离的增加迅速衰减。说明JH桨是一种以轴向 流场为主的桨型,它比推进桨轴流特性更好,更不易产生打漩现象,是溶解、悬浮搅拌的理 想桨型。%The three dimension fluid flow fields of impeller, traditional t ypical three-blade impeller, and JH-type new axial flow impeller have been teste d by using laser instrument. The analysis results show that the axial flow field of traditional three-blade impeller is not uniform but with W shape, it's radi al speed is propotional to radius, impeller with this type is easy to make verte n its circular speed increasing as radius increasing is very great. This indicat es that this impeller is a type of impeller which has axial fluid flow field a s main field and circular fluid flow field as company field. The axial speed fie ld of impeller distributes uniformly, but the uniformity decreases as the incre ase of distance to impeller. There is low speed area near the axle, its radi al s peed field is small but still exists beyond the blade radius. This shows that im p eller is not an impeller with pure axial speed field. The axial speed field of

  3. Modified approach for calculating axial vector vacuum susceptibility

    International Nuclear Information System (INIS)

    We generalize our previous work [Phys. Rev. C 72, 035202 (2005)] on the linear response theory of the dressed quark propagator in the presence of a constant external field to the case of a variable external field in order to make it applicable to a wider class of problems. Using the axial vector vacuum susceptibility as an illustration, we apply this general formalism to extract a new expression for the axial vector vacuum susceptibility in the quantum chromodynamical (QCD) sum rule two-point external field formula. The numerical values of the axial vector vacuum susceptibility are calculated within the framework of the rainbow-ladder approximation of the Dyson-Schwinger approach. A comparison with the results of the previous approaches is given

  4. Mass spectrometers with energy focusing: Combinations of magnetic and electric sector fields whose mean planes of deflection are tilted with respect to each other

    International Nuclear Information System (INIS)

    First a combination of two sector fields is considered, for instance a homogeneous magnetic field followed by an electric cylinder condenser. The mean planes of deflection of the fields are tilted with respect to each other by an oblique angle. Such a combination has astigmatic focusing properties for paraxial rays of ions of certain mass and energy coming from an object point assumed at a certain distance before the first field on the incoming central ray. At different distances from the field combination are formed, calculated in first order, two real or virtual straight astigmatic focusing lines which are perpendicular to each other and to the outgoing central ray. By proper assumptions of the dimensions of the combination it can be arranged that its first order energy dispersion and one real of its astigmatic focusing lines have exactly the same direction. Then by addition of a third sector field (again a homogeneous magnetic field) it can be achieved that the astigmatic focusing will be changed into a stigmatic one while at the same time the energy dispersion can be reduced to small values. The mass dispersion of this three field combination in the given numerical example is about perpendicular to the direction of the energy dispersion. (orig.)

  5. Study of neutron spectrometers for ITER

    International Nuclear Information System (INIS)

    A review is presented of the developments in the field of neutron emission spectrometry (NES) which is of relevance for identifying the role of NES diagnostics on ITER and selecting suitable instrumentation. Neutron spectrometers will be part of the ITER neutron diagnostic complement and this study makes a special effort to examine which performance characteristics the spectrometers should possess to provide the best burning plasma diagnostic information together with neutron cameras and neutron yield monitors. The performance of NES diagnostics is coupled to how much interface space can be provided which has lead to an interest to find compact instruments and their NES capabilities. This study assesses all known spectrometer types of potential interest for ITER and makes a ranking of their performance (as demonstrated or projected), which, in turn, are compared with ITER measurement requirements as a reference; the ratio of diagnostic performance to interface cost for different spectrometers is also discussed for different spectrometer types. The overall result of the study is an assessment of which diagnostic functions neutron measurements can provide in burning plasma fusion experiments on ITER and the role that NES can play depending on the category of instrument installed. Of special note is the result that much higher quality diagnostic information can be obtained from neutron measurements with total yield monitors, profile flux cameras and spectrometers when the synergy in the data is considered in the analysis and interpretation

  6. Study of neutron spectrometers for ITER

    Energy Technology Data Exchange (ETDEWEB)

    Kaellne, Jan

    2005-11-15

    A review is presented of the developments in the field of neutron emission spectrometry (NES) which is of relevance for identifying the role of NES diagnostics on ITER and selecting suitable instrumentation. Neutron spectrometers will be part of the ITER neutron diagnostic complement and this study makes a special effort to examine which performance characteristics the spectrometers should possess to provide the best burning plasma diagnostic information together with neutron cameras and neutron yield monitors. The performance of NES diagnostics is coupled to how much interface space can be provided which has lead to an interest to find compact instruments and their NES capabilities. This study assesses all known spectrometer types of potential interest for ITER and makes a ranking of their performance (as demonstrated or projected), which, in turn, are compared with ITER measurement requirements as a reference; the ratio of diagnostic performance to interface cost for different spectrometers is also discussed for different spectrometer types. The overall result of the study is an assessment of which diagnostic functions neutron measurements can provide in burning plasma fusion experiments on ITER and the role that NES can play depending on the category of instrument installed. Of special note is the result that much higher quality diagnostic information can be obtained from neutron measurements with total yield monitors, profile flux cameras and spectrometers when the synergy in the data is considered in the analysis and interpretation.

  7. Axial-symmetrical domain structures in ferrite-garnet films

    International Nuclear Information System (INIS)

    Applying the improved technique of double ultrahigh-speed photography one studied occurrence and progress of domain structure upon magnetization of a small section of (BiLaTm)3(FeGa)5O12 ferrite-garnet film prior to saturation. The radial deformation affecting the specimen on the magnetized coil side was determined to break single-axis anisotropy resulting in occurrence of axial-oriented band domain structure inside the magnetized range. That structure period reduced with growth of the pulse field amplitude. Band axial-oriented domain structure is formed under the effect of the magnetostatic axisymmetric field

  8. An Axial-Vector Photon in a Mirror World

    Science.gov (United States)

    Sharafiddinov, Rasulkhozha S.

    2016-03-01

    The unity of symmetry laws emphasizes, in the case of a mirror CP-even Dirac Lagrangian, the ideas of the left- and right-handed axial-vector photons referring to long- and short-lived bosons of true neutrality, respectively. Such a difference in lifetimes expresses the unidenticality of masses, energies and momenta of axial-vector photons of the different components. They define the unified field theory equation of C-odd particles with an integral spin. Together with a new equation of a theory of truly neutral particles with the half-integral spin, the latter reflects the availability in their nature of the second type of the local axial-vector gauge transformation responsible for origination in the Lagrangian of C-oddity of an interaction Newton component giving an axial-vector mass to all the interacting particles and fields. The mirror axial-vector mass, energy and momentum operators constitute a CP-invariant equation of quantum mechanics, confirming that each of them can individually influence on matter field. Thereby, findings suggest at the level of the mass-charge structure of gauge invariance a new equation for the C-noninvariant Lagrangian.

  9. Axial structure of the nucleon

    Energy Technology Data Exchange (ETDEWEB)

    Veronique Bernard; Latifa Elouadrhiri; Ulf-G Meissner

    2002-01-01

    We review the current status of experimental and theoretical understanding of the axial nucleon structure at low and moderate energies. Topics considered include (quasi)elastic (anti)neutrino-nucleon scattering, charged pion electroproduction off nucleons and ordinary as well as radiative muon capture on the proton.

  10. Magnetron mass spectrometer

    International Nuclear Information System (INIS)

    A magnetron mass-spectrometer characterized by increased sensitivity at low power is described. The mass-spectrometer contains ion source cylindrical analyzer located on its axis, ion collector and magnetic system. For decreasing consumed power the ion source is fixed at the end of the analyzer and it represents two coaXial cylinders located between plane electrodes, in one of which a ring slot takes place and the other one is connected with positive terminal of discharge voltage source. The magnetic system represents ring-form magnets fixed by similar poles to each other and separated by washers of magnetic-soft material, the washers being placed in the plane of the ion source. The analyzed ions in the described mass-spectrometer are obtained mainly at the expense of resonance recharge that increases accuracy of measurements due to decrease of fragment peak intensity

  11. Compact Grism Spectrometer

    Science.gov (United States)

    Teare, S. W.

    2003-05-01

    Many observatories and instrument builders are retrofitting visible and near-infrared spectrometers into their existing imaging cameras. Camera designs that reimage the focal plane and have the optical filters located in a pseudo collimated beam are ideal candidates for the addition of a spectrometer. One device commonly used as the dispersing element for such spectrometers is a grism. The traditional grism is constructed from a prism that has had a diffraction grating applied on one surface. The objective of such a design is to use the prism wedge angle to select the desired "in-line" or "zero-deviation" wavelength that passes through on axis. The grating on the surface of the prism provides much of the dispersion for the spectrometer. A grism can also be used in a "constant-dispersion" design which provides an almost linear spatial scale across the spectrum. In this paper we provide an overview of the development of a grism spectrometer for use in a near infrared camera and demonstrate that a compact grism spectrometer can be developed on a very modest budget that can be afforded at almost any facility. The grism design was prototyped using visible light and then a final device was constructed which provides partial coverage in the near infrared I, J, H and K astronomical bands using the appropriate band pass filter for order sorting. The near infrared grism presented here provides a spectral resolution of about 650 and velocity resolution of about 450 km/s. The design of this grism relied on a computer code called Xspect, developed by the author, to determine the various critical parameters of the grism. This work was supported by a small equipment grant from NASA and administered by the AAS.

  12. Pion electroproduction, partially conserved axial-vector current, chiral Ward identities, and the axial form factor revisited

    International Nuclear Information System (INIS)

    We reinvestigate Adler's partially conserved axial-vector current relation in the presence of an external electromagnetic field within the framework of QCD coupled to external fields. We discuss pion electroproduction within a tree-level approximation to chiral perturbation theory and explicitly verify a chiral Ward identity referred to as the Adler-Gilman relation. We critically examine soft-momentum techniques and point out how inadmissable approximations may lead to results incompatible with chiral symmetry. As a result we confirm that threshold pion electroproduction is indeed a tool to obtain information on the axial form factor of the nucleon

  13. Axial Shock in a Cylindrical Plasma with Current

    International Nuclear Information System (INIS)

    Hugoniot relations of a two-dimensional axial shock with current and magnetic field in a cylindrical shock tube were investigated by a numerical method. The radial profiles of the magnetic field, electric current, pressures, flow velocities and temperatures between the up- and down-stream radial force-balanced plasma of the shock were revealed by numerical analysis. It is clearly found that the axial shock can lead to two effects: one is an inverse skin effect (i.e., the current density rises towards the center of the conductor), the another is a reversed current effect which occurs near the edge and about a half radius. It is also found that the radial gradient of pressure, density and temperature all become very large near the center due to the axial shock

  14. Numerical analysis of cavitation within slanted axial-flow pump

    Institute of Scientific and Technical Information of China (English)

    张睿; 陈红勋

    2013-01-01

    In this paper, the cavitating flow within a slanted axial-flow pump is numerically researched. The hydraulic and cavitation performance of the slanted axial-flow pump under different operation conditions are estimated. Compared with the experimental hydraulic performance curves, the numerical results show that the filter-based model is better than the standard k-e model to predict the parameters of hydraulic performance. In cavitation simulation, compared with the experimental results, the proposed numerical method has good predicting ability. Under different cavitation conditions, the internal cavitating flow fields within slanted axial-flow pump are investigated. Compared with flow visualization results, the major internal flow features can be effectively grasped. In order to explore the origin of the cavitation performance breakdown, the Boundary Vorticity Flux (BVF) is introduced to diagnose the cavitating flow fields. The analysis results indicate that the cavitation performance drop is relevant to the instability of cavitating flow on the blade suction surface.

  15. Multi-channel electric aerosol spectrometer

    Science.gov (United States)

    Mirme, A.; Noppel, M.; Peil, I.; Salm, J.; Tamm, E.; Tammet, H.

    Multi-channel electric mobility spectrometry is a most efficient technique for the rapid measurement of an unstable aerosol particle size spectrum. The measuring range of the spectrometer from 10 microns to 10 microns is achieved by applying diffusional and field charging mechanisms simultaneously. On-line data processing is carried out with a microcomputer. Experimental calibration ensures correctness of measurement.

  16. Time of flight spherotron mass spectrometer

    International Nuclear Information System (INIS)

    The possibility of using the spherotron, the mass spectrometer with crossed spherical electric and inhomogeneous magnetic fields, as a TOF mass spectrometry instrument has been analyzed. The possibility of achieving triple isochronous focusing has been shown. The estimates for the mass dispersion and resolutions are derived. (author)

  17. Exact Axially Symmetric Solution in f(T) Gravity Theory

    OpenAIRE

    2014-01-01

    A general tetrad field with sixteen unknown functions is applied to the field equations of f(T) gravity theory. An analytic vacuum solution is derived with two constants of integration and an angle Φ that depends on the angle coordinate ϕ and radial coordinate r . The tetrad field of this solution is axially symmetric and the scalar torsion vanishes. We calculate the associated metric of the derived solution and show that it represents Kerr spacetime. Finally, we show that the derived solutio...

  18. The Electroweak Standard Model in the Axial Gauge

    CERN Document Server

    Dams, C; Dams, Chris; Kleiss, Ronald

    2004-01-01

    We derive the Feynman rules of the standard model in the axial gauge. After this we prove that the fields $\\phi_W$ and $\\phi_Z$ do not correspond to physical particles. As a consequence, these fields cannot appear as incoming or outgoing lines in Feynman graphs. We then calculate the contribution of these fields in the case of a particular decay mode of the top quark.

  19. Nucleon's axial-vector form factor in the hard-wall AdS/QCD model

    CERN Document Server

    Mamedov, Shahin; Huseynova, Narmin; Atayev, Ibrahim

    2016-01-01

    The axial-vector form factor of the nucleons is considered in the framework of hard-wall model of holographic QCD. A new interaction term between the bulk gauge and matter fields was included into the interaction Lagrangian. We obtain the axial-vector form factor of nucleons in the boundary QCD from the bulk action using AdS/CFT correspondence. The momentum square dependence of the axial-vector form factor is analysed numerically.

  20. The Dynamics of Stall and Surge Behavior in Axial-Centrifugal Compressors

    OpenAIRE

    Cousins, William T.

    1997-01-01

    The phenomena of stall and surge in axial-centrifugal compressors is investigated through high-response measurements of both the pressure field and the flowfield throughout the surge cycle. A unique high-response forward-facing and aft-facing probe provides flow information. Several axial-centrifugal compressors are examined, both in compressor rigs and engines. Extensive discussion is presented on the differences in axial and centrifugal rotors and their effect on the system response char...

  1. Cyclotrons as mass spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Clark, D.J.

    1984-04-01

    The principles and design choices for cyclotrons as mass spectrometers are described. They are illustrated by examples of cyclotrons developed by various groups for this purpose. The use of present high energy cyclotrons for mass spectrometry is also described. 28 references, 12 figures.

  2. The Omega spectrometer

    CERN Multimedia

    1972-01-01

    The Omega spectrometer which came into action during the year. An array of optical spark chambers can be seen withdrawn from the magnet aperture. In the 'igloo' above the magnet is located the Plumbicon camera system which collects information from the spark chambers.

  3. Speckle-based spectrometer

    DEFF Research Database (Denmark)

    Chakrabarti, Maumita; Jakobsen, Michael Linde; Hanson, Steen Grüner

    2015-01-01

    A novel spectrometer concept is analyzed and experimentally verified. The method relies on probing the speckle displacement due to a change in the incident wavelength. A rough surface is illuminated at an oblique angle, and the peak position of the covariance between the speckle patterns observed...

  4. Cyclotrons as mass spectrometers

    International Nuclear Information System (INIS)

    The principles and design choices for cyclotrons as mass spectrometers are described. They are illustrated by examples of cyclotrons developed by various groups for this purpose. The use of present high energy cyclotrons for mass spectrometry is also described. 28 references, 12 figures

  5. Spherical electrostatic electron spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Yang, T.S.; Kolk, B.; Kachnowski, T.; Trooster, J.; Benczer-Koller, N. (Rutgers - the State Univ., New Brunswick, NJ (USA). Dept. of Physics)

    1982-06-15

    A high transmission, low energy spherical electrostatic electron spectrometer particularly suited to the geometry required for Moessbauer-conversion electron spectroscopy was built. A transmission of 13% at an energy resolution of 2% was obtained with an 0.5 cm diameter source of 13.6 keV electrons. Applications to the study of hyperfine interactions of surfaces and interfaces are discussed.

  6. An Axial Vector Photon in a Mirror World

    CERN Document Server

    Sharafiddinov, Rasulkhozha S

    2015-01-01

    The unity of symmetry laws emphasizes, in the case of a mirror CP-even Dirac Lagrangian, the ideas of the left- and right-handed axial-vector photons referring to long- and short-lived bosons of true neutrality, respectively. Such a difference in lifetimes expresses the unidenticality of masses, energies and momenta of axial-vector photons of the different components. They define the unified field theory equation of C-odd particles with an integral spin. Together with a new equation of a theory of truly neutral particles with the half-integral spin, the latter reflects the availability in their nature of the second type of the local axial-vector gauge transformation responsible for origination in the Lagrangian of C-oddity of an interaction Newton component giving an axial-vector mass to all the interacting particles and fields. The mirror axial-vector mass, energy and momentum operators constitute a CP-invariant equation of quantum mechanics, confirming that each of them can individually influence on matter ...

  7. The Pickup Ion Composition Spectrometer

    Science.gov (United States)

    Gilbert, Jason A.; Zurbuchen, Thomas H.; Battel, Steven

    2016-06-01

    Observations of newly ionized atoms that are picked up by the magnetic field in the expanding solar wind contain crucial information about the gas or dust compositions of their origins. The pickup ions (PUIs) are collected by plasma mass spectrometers and analyzed for their density, composition, and velocity distribution. In addition to measurements of PUIs from planetary sources, in situ measurements of interstellar gas have been made possible by spectrometers capable of differentiating between heavy ions of solar and interstellar origin. While important research has been done on these often singly charged ions, the instruments that have detected many of them were designed for the energy range and ionic charge states of the solar wind and energized particle populations, and not for pickup ions. An instrument optimized for the complete energy and time-of-flight characterization of pickup ions will unlock a wealth of data on these hitherto unobserved or unresolved PUI species. The Pickup Ion Composition Spectrometer (PICSpec) is one such instrument and can enable the next generation of pickup ion and isotopic mass composition measurements. By combining a large-gap time-of-flight-energy sensor with a -100 kV high-voltage power supply for ion acceleration, PUIs will not only be above the detection threshold of traditional solid-state energy detectors but also be resolved sufficiently in time of flight that isotopic composition can be determined. This technology will lead to a new generation of space composition instruments, optimized for measurements of both heliospheric and planetary pickup ions.

  8. Axially symmetric rotating traversable wormholes

    CERN Document Server

    Kuhfittig, P K F

    2003-01-01

    This paper generalizes the static and spherically symmetric traversable wormhole geometry to a rotating axially symmetric one with a time-dependent angular velocity by means of an exact solution. It was found that the violation of the weak energy condition, although unavoidable, is considerably less severe than in the static spherically symmetric case. The radial tidal constraint is more easily met due to the rotation. Similar improvements are seen in one of the lateral tidal constraints. The magnitude of the angular velocity may have little effect on the weak energy condition violation for an axially symmetric wormhole. For a spherically symmetric one, however, the violation becomes less severe with increasing angular velocity. The time rate of change of the angular velocity, on the other hand, was found to have no effect at all. Finally, the angular velocity must depend only on the radial coordinate, confirming an earlier result.

  9. An all-cryogenic THz transmission spectrometer

    OpenAIRE

    Burke, P. J.; Eisenstein, J. P.; Pfeiffer, L. N.; West, K.W.

    2002-01-01

    This paper describes a THz transmission spectrometer for the spectral range of 2-65 cm^-1 (100 GHz to 2 THz) with a spectral resolution of at least 1.8 cm^-1 (50 GHz) where the source, sample, and detector are all fully contained in a cryogenic environment. Cyclotron emission from a two-dimensional electron gas heated with an electrical current serves as a magnetic field tunable source. The spectrometer is demonstrated at 4.2 K by measuring the resonant cyclotron absorption of a second two di...

  10. Software Polarization Spectrometer "PolariS"

    OpenAIRE

    Mizuno, Izumi; Kameno, Seiji; Kano, Amane; Kuroo, Makoto; Nakamura, Fumitaka; KAWAGUCHI, Noriyuki; Shibata, Katsunori M.; Kuji, Seisuke; Kuno, Nario

    2014-01-01

    We have developed a software-based polarization spectrometer, PolariS, to acquire full-Stokes spectra with a very high spectral resolution of 61 Hz. The primary aim of PolariS is to measure the magnetic fields in dense star-forming cores by detecting the Zeeman splitting of molecular emission lines. The spectrometer consists of a commercially available digital sampler and a Linux computer. The computer is equipped with a graphics processing unit (GPU) to process FFT and cross-correlation usin...

  11. In Situ Mass Spectrometer Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The In Situ Mass Spectrometer projects focuses on a specific subsystem to leverage advanced research for laser-based in situ mass spectrometer development...

  12. Miniature Ion-Mobility Spectrometer

    Science.gov (United States)

    Hartley, Frank T.

    2006-01-01

    The figure depicts a proposed miniature ion-mobility spectrometer that would be fabricated by micromachining. Unlike prior ion-mobility spectrometers, the proposed instrument would not be based on a time-of-flight principle and, consequently, would not have some of the disadvantageous characteristics of prior time-of-flight ion-mobility spectrometers. For example, one of these characteristics is the need for a bulky carrier-gas-feeding subsystem that includes a shutter gate to provide short pulses of gas in order to generate short pulses of ions. For another example, there is need for a complex device to generate pulses of ions from the pulses of gas and the device is capable of ionizing only a fraction of the incoming gas molecules; these characteristics preclude miniaturization. In contrast, the proposed instrument would not require a carrier-gas-feeding subsystem and would include a simple, highly compact device that would ionize all the molecules passing through it. The ionization device in the proposed instrument would be a 0.1-micron-thick dielectric membrane with metal electrodes on both sides. Small conical holes would be micromachined through the membrane and electrodes. An electric potential of the order of a volt applied between the membrane electrodes would give rise to an electric field of the order of several megavolts per meter in the submicron gap between the electrodes. An electric field of this magnitude would be sufficient to ionize all the molecules that enter the holes. Ionization (but not avalanche arcing) would occur because the distance between the ionizing electrodes would be less than the mean free path of gas molecules at the operating pressure of instrument. An accelerating grid would be located inside the instrument, downstream from the ionizing membrane. The electric potential applied to this grid would be negative relative to the potential on the inside electrode of the ionizing membrane and would be of a magnitude sufficient to

  13. On the axially symmetric equilibrium of a magnetically confined plasma

    International Nuclear Information System (INIS)

    The axially symmetric equilibrium of a magnetically confined plasma is reconsidered, with the special purpose of studying high-beta schemes with a purely poloidal magnetic field. A number of special solutions of the pressure and magnetic flux functions are shown to exist, the obtained results may form starting-points in a further analysis of physically relevant configurations. (Auth.)

  14. Miniature, sub-nanometer resolution Talbot spectrometer.

    Science.gov (United States)

    Ye, Erika; Atabaki, Amir H; Han, Ningren; Ram, Rajeev J

    2016-06-01

    Miniaturization of optical spectrometers has a significant practical value as it can enable compact, affordable spectroscopic systems for chemical and biological sensing applications. For many applications, the spectrometer must gather light from sources that span a wide range of emission angles and wavelengths. Here, we report a lens-free spectrometer that is simultaneously compact (3), of high resolution (<1  nm), and has a clear aperture (of 10×10  mm). The wavelength-scale pattern in the dispersive element strongly diffracts the input light to produce non-paraxial mid-field diffraction patterns that are then recorded using an optimally matched image sensor and processed to reconstruct the spectrum. PMID:27244382

  15. An All-Cryogenic THz Transmission Spectrometer

    CERN Document Server

    Burke, P J; Pfeiffer, L N; West, K W

    2001-01-01

    This paper describes a THz transmission spectrometer for the spectral range of 2-65 cm^-1 (100 GHz to 2 THz) with a spectral resolution of at least 1.8 cm^-1 (50 GHz) where the source, sample, and detector are all fully contained in a cryogenic environment. Cyclotron emission from a two-dimensional electron gas heated with an electrical current serves as a magnetic field tunable source. The spectrometer is demonstrated at 4.2 K by measuring the resonant cyclotron absorption of a second two dimensional electron gas. Unique aspects of the spectrometer are that 1) an ultra-broadband detector is used and 2) the emitter is run quasi-continuously with a chopping frequency of only 1 Hz. Since optical coupling to room temperature components is not necessary, this technique is compatible with ultra-low temperature (sub 100 mK) operation.

  16. Fast neutron detection with a segmented spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Langford, T.J., E-mail: thomas.langford@yale.edu [Department of Physics, University of Maryland, College Park, MD 20742 (United States); Institute for Research in Electronics and Applied Physics, University of Maryland, College Park, MD 20742 (United States); Bass, C.D. [National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); Beise, E.J.; Breuer, H.; Erwin, D.K. [Department of Physics, University of Maryland, College Park, MD 20742 (United States); Heimbach, C.R.; Nico, J.S. [National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States)

    2015-01-21

    A fast neutron spectrometer consisting of segmented plastic scintillator and {sup 3}He proportional counters was constructed for the measurement of neutrons in the energy range 1–200 MeV. We discuss its design, principles of operation, and the method of analysis. The detector is capable of observing very low neutron fluxes in the presence of ambient gamma background and does not require scintillator pulse-shape discrimination. The spectrometer was characterized for its energy response in fast neutron fields of 2.5 MeV and 14 MeV, and the results are compared with Monte Carlo simulations. Measurements of the fast neutron flux and energy response at 120 m above sea-level (39.130°N, 77.218°W) and at a depth of 560 m in a limestone mine are presented. Finally, the design of a spectrometer with improved sensitivity and energy resolution is discussed.

  17. Fast Neutron Detection with a Segmented Spectrometer

    CERN Document Server

    Langford, T J; Beise, E J; Breuer, H; Erwin, D K; Heimbach, C R; Nico, J S

    2014-01-01

    A fast neutron spectrometer consisting of segmented plastic scintillator and He-3 proportional counters was constructed for the measurement of neutrons in the energy range 1 MeV to 200 MeV. We discuss its design, principles of operation, and the method of analysis. The detector is capable of observing very low neutron fluxes in the presence of ambient gamma background and does not require scintillator pulse-shape discrimination The spectrometer was characterized for energy resolution and efficiency in fast neutron fields of 2.5 MeV, 14 MeV, and fission spectrum neutrons, and the results are compared with Monte Carlo simulations. Measurements of the fast neutron flux and energy response at 120 m above sea-level (39.130 deg. N, 77.218 deg. W) and at a depth of 560 m in a limestone mine are presented. Finally, the design of a spectrometer with improved sensitivity and energy resolution is discussed.

  18. Miniaturized Energy Spectrometer for Space Plasma Measurements

    Science.gov (United States)

    Goes de Lima, Raphaela; Scime, Earl; Keesee, Amy; Lusk, Greg

    2015-11-01

    Taking advantage of technological developments in lithographic fabrication techniques over the past two decades, we have designed an ultra-compact plasma spectrometer that requires only low voltage power supplies, no microchannel plates, and has a high aperture area to instrument area ratio. The designed target is for ions in the 3- 20 keV range with a highly directional field of view. In addition to reducing mass, size, and voltage requirements, the new design will revolutionize the manufacturing process of plasma spectrometers, enabling large quantities of identical instruments to be manufactured at low individual unit cost. Such a plasma spectrometer is ideal for Heliophysics plasma investigations, particularly for small satellite and multi-spacecraft missions. Here we present initial measurements of the performance of the instrument components and designs of the electronics for the low energy threshold solid state detector. Work Support under NASA grant - NNX14AJ36G.

  19. Preliminary Test Results for the MICE Spectrometer Superconducting Solenoids

    Energy Technology Data Exchange (ETDEWEB)

    Virostek, Steve P.; Green, Michael A; Li, Derun; Zisman, Michael S.; Wang, S.T.; Wahrer, R.; Taylor, Clyde; Lu, X.; Chen, J. Y.; Wang, Mimi; Juang, Tiki

    2008-08-02

    This report describes the MICE spectrometer solenoids as built. Each magnet consists of five superconducting coils. Two coils are used to tune the beam going from or to the MICE spectrometer from the rest of the MICE cooling channel. Three spectrometer coils (two end coils and a long center coil) are used to create a uniform 4 T field (to {+-}0.3 percent) over a length of 1.0 m within a diameter of 0.3 m. The three-coil spectrometer set is connected in series. The two end coils use small power supplies to tune the uniform field region where the scintillating fiber tracker is located. This paper will present the results of the preliminary testing of the first spectrometer solenoid.

  20. Preliminary Test Results for the MICE Spectrometer Superconducting Solenoids

    International Nuclear Information System (INIS)

    This report describes the MICE spectrometer solenoids as built. Each magnet consists of five superconducting coils. Two coils are used to tune the beam going from or to the MICE spectrometer from the rest of the MICE cooling channel. Three spectrometer coils (two end coils and a long center coil) are used to create a uniform 4 T field (to ±0.3 percent) over a length of 1.0 m within a diameter of 0.3 m. The three-coil spectrometer set is connected in series. The two end coils use small power supplies to tune the uniform field region where the scintillating fiber tracker is located. This paper will present the results of the preliminary testing of the first spectrometer solenoid

  1. Simulation of the SAGE spectrometer

    Science.gov (United States)

    Cox, D. M.; Konki, J.; Greenlees, P. T.; Hauschild, K.; Herzberg, R.-D.; Pakarinen, J.; Papadakis, P.; Rahkila, P.; Sandzelius, M.; Sorri, J.

    2015-06-01

    The SAGE spectrometer combines a Ge-detector array with a Si detector to allow simultaneous detection of γ-rays and electrons. A comprehensive GEANT4 simulation package of the SAGE spectrometer has been developed with the ability to simulate the expected datasets based on user input files. The measured performance of the spectrometer is compared to the results obtained from the simulations.

  2. An effective theory for QCD with an axial chemical potential

    CERN Document Server

    Andrianov, Alexander A; Espriu, Domenec; Planells, Xumeu

    2013-01-01

    We consider the low energy realization of QCD in terms of meson fields when an axial chemical potential is present; a situation that may be relevant in heavy ion collisions. We shall demonstrate that the presence of an axial charge constitutes an explicit source of parity breaking. The eigenstates of strong interactions do not have a definite parity and interactions that would otherwise be forbidden compete with the familiar ones. In this work, we first focus on scalars and pseudoscalars that are described by a generalized linear sigma model; and next, we give some hints on how the Vector Meson Dominance model describes the vector sector.

  3. Axial Force at the Vessel Bottom Induced by Axial Impellers

    OpenAIRE

    I. Fořt; P. Hasal; A. Paglianti; F. Magelli

    2008-01-01

    This paper deals with the axial force affecting the flat bottom of a cylindrical stirred vessel. The vessel is equipped with four radial baffles and is stirred with a four 45° pitched blade impeller pumping downwards. The set of pressure transducers is located along the whole radius of the flat bottom between two radial baffles. The radial distribution of the dynamic pressures indicated by the transducers is measured in dependence on the impeller off-bottom clearance and impeller speed.It fol...

  4. Long-term field performance of a tunable diode laser absorption spectrometer for analysis of carbon isotopes of CO2 in forest air

    Directory of Open Access Journals (Sweden)

    D. R. Bowling

    2008-09-01

    Full Text Available Tunable diode laser absorption spectrometry (TDLAS is gaining in popularity for measuring the mole fraction [CO2] and stable isotopic composition (δ13C of carbon dioxide (CO2 in air in studies of biosphere-atmosphere gas exchange. Here we present a detailed examination of the performance of a commercially-available TDLAS located in a high-altitude subalpine coniferous forest (the Niwot Ridge AmeriFlux site, providing the first multi-year analysis of TDLAS instrument performance for measuring CO2 isotopes in the field. Air was sampled from five to nine vertical locations in and above the forest canopy every ten minutes for 2.4 years. A variety of methods were used to assess instrument performance. Measurement of two compressed air cylinders that were in place over the entire study establish the long-term field precision of 0.2 μmol mol−1 for [CO2] and 0.35‰ for δ13C, but after fixing several problems the isotope precision improved to 0.2permil (over the last several months. The TDLAS provided detail on variability of δ13C of atmospheric CO2 that was not represented in weekly flask samples, as well as information regarding the influence of large-scale (regional seasonal cycle and local forest processes on [CO2] and δ13C of CO2. There were also clear growing season and winter differences in the relative contributions of photosynthesis and respiration on the [CO2] and δ13C of forest air.

  5. Long-term field performance of a tunable diode laser absorption spectrometer for analysis of carbon isotopes of CO2 in forest air

    Directory of Open Access Journals (Sweden)

    J. W. C. White

    2008-05-01

    Full Text Available Tunable diode laser absorption spectrometry (TDLAS is gaining in popularity for measuring the mole fraction [CO2] and stable isotopic composition (δ13C of carbon dioxide (CO2 in air in studies of biosphere-atmosphere gas exchange. Here we present a detailed examination of the performance of a commercially-available TDLAS located in a high-altitude subalpine coniferous forest (the Niwot Ridge AmeriFlux site, providing the first multi-year analysis of TDLAS instrument performance for measuring CO2 isotopes in the field. Air was sampled from five to nine vertical locations in and above the forest canopy every ten minutes for 2.4 years. A variety of methods were used to assess instrument performance. Measurement of two compressed air cylinders that were in place over the entire study establish the long-term field precision of 0.2 μmol mol−1 for [CO2] and 0.35‰ for δ13C, but after fixing several problems the isotope precision improved to 0.2‰ (over the last several months. The TDLAS provided detail on variability of δ13C of atmospheric CO2 that was not represented in weekly flask samples, as well as information regarding the influence of large-scale (regional seasonal cycle and local forest processes on [CO2] and δ13C of CO2. There were also clear growing season and winter differences in the relative contributions of photosynthesis and respiration on the [CO2] and δ13C of forest air.

  6. Ion optics for large-acceptance magnetic spectrometers application to the MAGNEX spectrometer

    CERN Document Server

    Cunsolo, A; Foti, A; Lazzaro, A; Melita, A L; Nociforo, C; Shchepunov, V A; Winfield, J S

    2002-01-01

    The ion optics of large-acceptance magnetic spectrometers are discussed. General techniques based on a minimum of multi-purpose magnetic elements are described. The aberrations should be minimised by shaping the entrance and exit effective field boundaries of bending magnets, the residual terms being corrected by software. Field clamps, shims and surface coils (the latter to provide kinematic compensation) are also discussed. The results and formulae which we obtain are applied to the case of the large-acceptance (approx 50 msr) high-resolution magnetic spectrometer 'MAGNEX' at INFN-LNS Catania.

  7. 轴流式磁悬浮血泵流场数值模拟及溶血预测%Flow Field Numerical Simulation and Hemolytic Prediction for Axial Flow Maglev Blood Pump

    Institute of Scientific and Technical Information of China (English)

    吴华春; 龚高; 王子彦; 胡业发

    2013-01-01

    血泵流体动力分析是研发先进人工心脏泵的前提,血泵叶轮旋转时会对血细胞造成不同程度的机械损伤,从而导致溶血和血栓,严重时甚至危及患者生命.以设计的一种轴流式磁悬浮血泵为例,结合计算流体力学和结构优化设计,采用κ—ε模型、动网格技术和用户自定义函数技术,在轴流式磁悬浮血泵内部三维流场数值模拟的基础上,分析轴流式磁悬浮血泵流道的剪应力分布,探索血液流量与叶轮转速的关系,利用粒子追踪法获取血液细胞流动轨迹,建立一种轴流式磁悬浮血泵的溶血数学模型,阐述轴流式磁悬浮血泵溶血性能预测的方法和机理.研究结果可为轴流式磁悬浮血泵的结构设计和降低溶血提供重要依据.%Blood pump impeller causes varying degrees of mechanical damage of blood cells when rotating, which will lead to hemolysis and thrombosis, even threat patient life. For an axial flow maglev blood pump, based on CFD and structural optimization design, using κ-ε model, dynamic mesh and user defined function ( UDF), a three — dimensional numerical simulation of axial flow maglev blood pump was carried on, hemolytic mathematical model was established, the flow shear stress distribution of axial flow maglev blood pump was obtained, the relationship between blood flow and impeller speed was explored, blood cell flow path was gotten based on particle tracking method and also do hemolysis prediction. This analysis provides an important basis for structure design and hemolysis reduce of axial flow maglev blood pump.

  8. Second harmonic generation of off axial vortex beam in the case of walk-off effect

    Science.gov (United States)

    Chen, Shunyi; Ding, Panfeng; Pu, Jixiong

    2016-07-01

    Process of off axial vortex beam propagating in negative uniaxial crystal is investigated in this work. Firstly, we get the formulae of the normalized electric field and calculate the location of vortices for second harmonic beam in two type of phase matching. Then, numerical analysis verifies that the intensity distribution and location of vortices of the first order original vortex beam depend on the walk-off angle and off axial magnitude. It is shown that, in type I phase matching, the distribution of vortices is symmetrical about the horizontal axis, the separation distance increases as the off axial magnitude increases or the off axial magnitude deceases. However, in type II phase matching, the vortices are symmetrical along with some vertical axis, and increase of the walk-off angle or off axial magnitude leads to larger separation distance. Finally, the case of high order original off axial vortex beam is also investigated.

  9. Effective mass spectrometer

    International Nuclear Information System (INIS)

    The history and major accomplishments of the Effective Mass Spectrometer (EMS) are described. In the eight years since the EMS turned on, 21 experiments have been completed by groups from nine institutions in 32 months of operation. Over 400 million triggers have been recorded on magnetic tape, resulting in 29 journal publications to date. A list of experimental proposals for the EMS and a sampling of results are presented. 12 figures, 4 tables

  10. Spherical electrostatic electron spectrometer

    Science.gov (United States)

    Yang, T.-S.; Kolk, B.; Kachnowski, T.; Trooster, J.; Benczer-Koller, N.

    1982-06-01

    A high transmission, low energy spherical electrostatic electron spectrometer particularly suited to the geometry required for Mössbauer-conversion electron spectroscopy was built. A transmission of 13% at an energy resolution of 2% was obtained with an 0.5 cm diameter source of 13.6 keV electrons. Applications to the study of hyperfine interactions of surfaces and interfaces are discussed.

  11. ALICE photon spectrometer crystals

    CERN Multimedia

    Maximilien Brice

    2006-01-01

    Members of the mechanical assembly team insert the last few crystals into the first module of ALICE's photon spectrometer. These crystals are made from lead-tungstate, a crystal as clear as glass but with nearly four times the density. When a high-energy particle passes through one of these crystals it will scintillate, emitting a flash of light allowing the energy of photons, electrons and positrons to be measured.

  12. Magnetic spectrometer control system

    International Nuclear Information System (INIS)

    The design and implementation of a new computerized control system for the several devices of the magnetic spectrometer at TANDAR Laboratory is described. This system, as a main difference from the preexisting one, is compatible with almost any operating systems of wide spread use available in PC. This allows on-line measurement and control of all signals from any terminal of a computer network. (author)

  13. On-line control and detection system for crystalline neutron for spectrometer

    International Nuclear Information System (INIS)

    On-line control and detection system for the crystalline neutron three-axial spectrometer is described, the system being based on microcomputer ''Ehlektronika-60'' and electron units in KAMAK standard. System software is proefly described. The application of this system permits to speed up measurements 2-3 times in comparison with control systems of HELENA type

  14. Mass spectrometers: instrumentation

    Science.gov (United States)

    Cooks, R. G.; Hoke, S. H., II; Morand, K. L.; Lammert, S. A.

    1992-09-01

    Developments in mass spectrometry instrumentation over the past three years are reviewed. The subject is characterized by an enormous diversity of designs, a high degree of competition between different laboratories working with either different or similar techniques and by extremely rapid progress in improving analytical performance. Instruments can be grouped into genealogical charts based on their physical and conceptual interrelationships. This is illustrated using mass analyzers of different types. The time course of development of particular instrumental concepts is illustrated in terms of the s-curves typical of cell growth. Examples are given of instruments which are at the exponential, linear and mature growth stages. The prime examples used are respectively: (i) hybrid instruments designed to study reactive collisions of ions with surfaces: (ii) the Paul ion trap; and (iii) the triple quadrupole mass spectrometer. In the area of ion/surface collisions, reactive collisions such as hydrogen radical abstraction from the surface by the impinging ion are studied. They are shown to depend upon the chemical nature of the surface through the use of experiments which utilize self-assembled monolayers as surfaces. The internal energy deposited during surface-induced dissociation upon collision with different surfaces in a BEEQ instrument is also discussed. Attention is also given to a second area of emerging instrumentation, namely technology which allows mass spectrometers to be used for on-line monitoring of fluid streams. A summary of recent improvements in the performance of the rapidly developing quadrupole ion trap instrument illustrates this stage of instrument development. Improvements in resolution and mass range and their application to the characterization of biomolecules are described. The interaction of theory with experiment is illustrated through the role of simulations of ion motion in the ion trap. It is emphasized that mature instruments play a

  15. Strange axial-vector mesons

    International Nuclear Information System (INIS)

    The strange axial-vector mesons K1 (1270) and K1 (1400) are reanalyzed in the light of the updated experimental information and compared with the recent result on the Kππ production in τ decay. The mixing angle between the strange mesons of 3P1 and 1P1 is determined by the partial decay rates, and, independently, by the masses. They lead to θK∼33 degree or 57 degree. The observed K1 (1400) production dominance in the τ decay favors θK∼33 degree. Flavor-SU(3) breaking of 20% or so in the production amplitudes can explain quantitatively the observed production ratio

  16. PWR AXIAL BURNUP PROFILE ANALYSIS

    International Nuclear Information System (INIS)

    The purpose of this activity is to develop a representative ''limiting'' axial burnup profile for pressurized water reactors (PWRs), which would encompass the isotopic axial variations caused by different assembly irradiation histories, and produce conservative isotopics with respect to criticality. The effect that the low burnup regions near the ends of spent fuel have on system reactivity is termed the ''end-effect''. This calculation will quantify the end-effects associated with Pressurized Water Reactor (PWR) fuel assemblies emplaced in a hypothetical 21 PWR waste package. The scope of this calculation covers an initial enrichment range of 3.0 through 5.0 wt% U-235 and a burnup range of 10 through 50 GWd/MTU. This activity supports the validation of the process for ensuring conservative generation of spent fuel isotopics with respect to criticality safety applications, and the use of burnup credit for commercial spent nuclear fuel. The intended use of these results will be in the development of PWR waste package loading curves, and applications involving burnup credit. Limitations of this evaluation are that the limiting profiles are only confirmed for use with the B andW 15 x 15 fuel assembly design. However, this assembly design is considered bounding of all other typical commercial PWR fuel assembly designs. This calculation is subject to the Quality Assurance Requirements and Description (QARD) because this activity supports investigations of items or barriers on the Q-list (YMP 2001)

  17. PWR AXIAL BURNUP PROFILE ANALYSIS

    Energy Technology Data Exchange (ETDEWEB)

    J.M. Acaglione

    2003-09-17

    The purpose of this activity is to develop a representative ''limiting'' axial burnup profile for pressurized water reactors (PWRs), which would encompass the isotopic axial variations caused by different assembly irradiation histories, and produce conservative isotopics with respect to criticality. The effect that the low burnup regions near the ends of spent fuel have on system reactivity is termed the ''end-effect''. This calculation will quantify the end-effects associated with Pressurized Water Reactor (PWR) fuel assemblies emplaced in a hypothetical 21 PWR waste package. The scope of this calculation covers an initial enrichment range of 3.0 through 5.0 wt% U-235 and a burnup range of 10 through 50 GWd/MTU. This activity supports the validation of the process for ensuring conservative generation of spent fuel isotopics with respect to criticality safety applications, and the use of burnup credit for commercial spent nuclear fuel. The intended use of these results will be in the development of PWR waste package loading curves, and applications involving burnup credit. Limitations of this evaluation are that the limiting profiles are only confirmed for use with the B&W 15 x 15 fuel assembly design. However, this assembly design is considered bounding of all other typical commercial PWR fuel assembly designs. This calculation is subject to the Quality Assurance Requirements and Description (QARD) because this activity supports investigations of items or barriers on the Q-list (YMP 2001).

  18. Method for modifying axial fan's guard grill and its impact on operating characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Alic, G. [Hidria Institute Klima d.o.o., Godovic (Slovenia); Sirok, B.; Hocevar, M. [Faculty of Mechanical Engineering, Ljubljana (Slovenia)

    2010-06-15

    This paper presents the impact of guard grill on aerodynamic integral characteristic, the spectrum of sound pressure level and total sound power level at four characteristic operating points of axial fans with standard guard grill, with optimized guard grill and without guard grill. The study of guard grill's impact was conducted with measurements at integral level and local outflow velocity field of the axial fan without guard grill. The measurement results of the local outflow velocity field of the axial fan without guard grill at optimal operating point were used to model the optimized guard grill contour. The guard grill of axial fan has a significant impact on aerodynamic integral characteristic at free flow and mostly used operating region. The influence of guard grill is also characteristically reflected in the spectrum of sound pressure level via vortex shedding frequency and consequently at total sound power level of compared axial fans. (orig.)

  19. Republication of: New solutions to Einstein's equations of gravitation. B. Explicit determination of static, axially symmetric fields. By Rudolf Bach. With a supplement on the static two-body problem. By H. Weyl.

    Science.gov (United States)

    Bach, Rudolf; Weyl, Hermann

    2012-03-01

    This is the English translation of the third of a series of 3 papers by Hermann Weyl (the third one jointly with Rudolf Bach), first published in 1917-1922, in which the authors derived and discussed the now-famous Weyl two-body static axially symmetric vacuum solution of Einstein's equations. The English translations of the other two papers are published alongside this one. The papers have been selected by the Editors of General Relativity and Gravitation for re-publication in the Golden Oldies series of the journal. This republication is accompanied by an editorial note written by Gernot Neugebauer, David Petroff and Bahram Mashhoon, and by a brief biography of R. Bach, written by H. Goenner.

  20. Triple axis spectrometers

    International Nuclear Information System (INIS)

    Conventional triple-axis neutron spectroscopy was developed by Brockhouse over thirty years ago' and remains today a versatile and powerful tool for probing the dynamics of condensed matter. The original design of the triple axis spectrometer is technically simple and probes momentum and energy space on a point-by-point basis. This ability to systematically probe the scattering function in a way which only requires a few angles to be moved under computer control and where the observed data in general can be analysed using a pencil and graph paper or a simple fitting routine, has been essential for the success of the method. These constraints were quite reasonable at the time the technique was developed. Advances in computer based data acquisition, neutron beam optics, and position sensitive area detectors have been gradually implemented on many triple axis spectrometer spectrometers, but the full potential of this has not been fully exploited yet. Further improvement in terms of efficiency (beyond point by point inspection) and increased sensitivity (use of focusing optics whenever the problem allows it) could easily be up to a factor of 10-20 over present instruments for many problems at a cost which is negligible compared to that of increasing the flux of the source. The real cost will be in complexity - finding the optimal set-up for a given scan and interpreting the data as the they are taken. On-line transformation of the data for an appropriate display in Q, ω space and analysis tools will be equally important for this task, and the success of these new ideas will crucially depend on how well we solve these problems. (author)

  1. Mossbauer spectrometer radiation detector

    Science.gov (United States)

    Singh, J. J. (Inventor)

    1973-01-01

    A Mossbauer spectrometer with high efficiencies in both transmission and backscattering techniques is described. The device contains a sodium iodide crystal for detecting radiation caused by the Mossbauer effect, and two photomultipliers to collect the radiation detected by the crystal. When used in the transmission technique, the sample or scatterer is placed between the incident radiation source and the detector. When used in a backscattering technique, the detector is placed between the incident radiation source and the sample of scatterer such that the incident radiation will pass through a hole in the crystal and strike the sample. Diagrams of the instrument are provided.

  2. Broadband multimode fiber spectrometer

    CERN Document Server

    Liew, Seng Fatt; Choma, Michael A; Tagare, Hemant D; Cao, Hui

    2016-01-01

    A general-purpose all-fiber spectrometer is demonstrated to overcome the trade-off between spectral resolution and bandwidth. By integrating a wavelength division multiplexer with five multimode optical fibers, we have achieved 100 nm bandwidth with 0.03 nm resolution at wavelength 1500 nm. An efficient algorithm is developed to reconstruct the spectrum from the speckle pattern produced by interference of guided modes in the multimode fibers. Such algorithm enables a rapid, accurate reconstruction of both sparse and dense spectra in the presence of noise.

  3. Axial Vector $Z'$ and Anomaly Cancellation

    CERN Document Server

    Ismail, Ahmed; Tsao, Kuo-Hsing; Unwin, James

    2016-01-01

    Whilst the prospect of new $Z'$ gauge bosons with only axial couplings to the Standard Model (SM) fermions is widely discussed, examples of anomaly-free renormalisable models are lacking in the literature. We look to remedy this by constructing several motivated examples. Specifically, we consider axial vectors which couple universally to all SM fermions, as well as those which are generation-specific, leptophilic, and leptophobic. Anomaly cancellation typically requires the presence of new coloured and charged chiral fermions, and we argue that the masses of these new states must generally be comparable to that of the axial vector. Finally, an axial vector mediator could provide a portal between SM and hidden sector states, and we also consider the possibility that the axial vector couples to dark matter. If the dark matter relic density is set due to freeze-out via the axial vector, this strongly constrains the parameter space.

  4. Axial velocity in decaying swirl flow

    Science.gov (United States)

    Algifri, A. H.; Bhardwaj, R. K.; Rao, Y. V. N.

    1988-09-01

    Experiments were carried out on turbulent swirling flow with variable initial swirl at different flow rates to study the effect of swirl on axial velocity. A correlation was made between the defect in the swirling flow axial velocity and the swirl number which locally defines the swirl intensity. An expression which can be used to predict the axial velocity distribution of turbulent swirling flow in a pipe is presented.

  5. Sensorless Control of Axial Magnetic Bearings

    Science.gov (United States)

    Atsumo, Daichi; Yoshida, Toshiya; Ohniwa, Katsumi

    This paper describes a sensorless control method of axial active magnetic bearings (AMBs). At high frequencies, inductance of the axial electromagnets is hardly dependent on the airgap because of the eddy current effects of the non-laminated core. Therefore the carrier frequency should be 3 kHz below to improve the sensitivity to the airgap. In the experiment, Sensorless controll of the axial AMBs have been achieved.

  6. The QQDDQ magnet spectrometer 'BIG KARL'

    International Nuclear Information System (INIS)

    A magnet spectrometer consisting of two quadrupoles, two dipole magnets and another larger quadrupole in front of the detector was designed and installed at the nuclear research institute of the KFA Juelich. It has been used for charged-particle spectroscopy at the isochronous cyclotron since early 1979. Special features of the spectrometer are variable and high dispersion, coils for higher order field corrections in the dipole magnets and a focal plane perpendicular to the optical axis. A large mass-energy product of mE/q2 4 and the possibility of kinematical corrections up to K=0.8 make the instrument a very versatile tool for many experiments in the fields of nuclear and atomic physics. (orig.)

  7. A colloidal quantum dot spectrometer

    Science.gov (United States)

    Bao, Jie; Bawendi, Moungi G.

    2015-07-01

    Spectroscopy is carried out in almost every field of science, whenever light interacts with matter. Although sophisticated instruments with impressive performance characteristics are available, much effort continues to be invested in the development of miniaturized, cheap and easy-to-use systems. Current microspectrometer designs mostly use interference filters and interferometric optics that limit their photon efficiency, resolution and spectral range. Here we show that many of these limitations can be overcome by replacing interferometric optics with a two-dimensional absorptive filter array composed of colloidal quantum dots. Instead of measuring different bands of a spectrum individually after introducing temporal or spatial separations with gratings or interference-based narrowband filters, a colloidal quantum dot spectrometer measures a light spectrum based on the wavelength multiplexing principle: multiple spectral bands are encoded and detected simultaneously with one filter and one detector, respectively, with the array format allowing the process to be efficiently repeated many times using different filters with different encoding so that sufficient information is obtained to enable computational reconstruction of the target spectrum. We illustrate the performance of such a quantum dot microspectrometer, made from 195 different types of quantum dots with absorption features that cover a spectral range of 300 nanometres, by measuring shifts in spectral peak positions as small as one nanometre. Given this performance, demonstrable avenues for further improvement, the ease with which quantum dots can be processed and integrated, and their numerous finely tuneable bandgaps that cover a broad spectral range, we expect that quantum dot microspectrometers will be useful in applications where minimizing size, weight, cost and complexity of the spectrometer are critical.

  8. Axially symmetric Lorentzian wormholes in general relativity

    International Nuclear Information System (INIS)

    The field equations of Einstein's theory of general relativity, being local, do not fix the global structure of space-time. They admit topologically non-trivial solutions, including spatially closed universes and the amazing possibility of shortcuts for travel between distant regions in space and time - so-called Lorentzian wormholes. The aim of this thesis is to (mathematically) construct space-times which contain traversal wormholes connecting arbitrary distant regions of an asymptotically flat or asymptotically de Sitter universe. Since the wormhole mouths appear as two separate masses in the exterior space, space-time can at best be axially symmetric. We eliminate the non-staticity caused by the gravitational attraction of the mouths by anchoring them by strings held at infinity or, alternatively, by electric repulsion. The space-times are obtained by surgically grafting together well-known solutions of Einstein's equations along timelike hypersurfaces. This surgery naturally concentrates a non-zero stress-energy tensor on the boundary between the two space-times which can be investigated by using the standard thin shell formalism. It turns out that, when using charged black holes, the provided constructions are possible without violation of any of the energy conditions. In general, observers living in the axially symmetric, asymptotically flat (respectively asymptotically de Sitter) region axe able to send causal signals through the topologically non-trivial region. However, the wormhole space-times contain closed timelike curves. Because of this explicit violation of global hyperbolicity these models do not serve as counterexamples to known topological censorship theorems. (author)

  9. Axial asymmetry in the IVBM

    International Nuclear Information System (INIS)

    The dynamical symmetry limit of the two-fluid Interacting Vector Boson Model (IVBM), defined through the chain Sp(12,R) contains U(3,3) contains Up(3) x Un(3) contains SU*(3) contains SO(3), is considered and applied for the description of nuclear collective spectra exhibiting axially asymmetric features. The effect of the introduction of a Majorana interaction to the SU*(3) model Hamiltonian on the γ-band energies is studied. The theoretical predictions are compared with the experimental data for 192Os, 190Os, and 112Ru isotopes. It is shown that by taking into account the full symplectic structures in the considered dynamical symmetry of the IVBM, the proper description of the energy spectra and the γ-band energy staggering of the nuclei under considerations can be achieved. The obtained results show that the potential energy surfaces for the following two nuclei 192Os and 112Ru, possess almost γ-flat potentials with very shallow triaxial minima, suggesting a more complex and intermediate situation between γ-rigid and γ-unstable structures. Additionally, the absolute B(E2) intraband transition probabilities between the states of the ground-state band and γ band, as well as the B(M1) interband transition probabilities between the states of the ground and γ bands for the two nuclei 192Os and 190Os are calculated and compared with experiment and for the B(E2) values with the predictions of some other collective models incorporating the γ-rigid or γ-unstable structures. The obtained results agree well with the experimental data and reveal the relevance of the used dynamical symmetry of IVBM in the description of nuclei exhibiting axially asymmetric features in their spectra. (orig.)

  10. Simulation of the SAGE spectrometer

    International Nuclear Information System (INIS)

    The SAGE spectrometer combines a Ge-detector array with a Si detector to allow simultaneous detection of γ-rays and electrons. A comprehensive GEANT4 simulation package of the SAGE spectrometer has been developed with the ability to simulate the expected datasets based on user input files. The measured performance of the spectrometer is compared to the results obtained from the simulations. (orig.)

  11. Simulation of the SAGE spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Cox, D.M.; Herzberg, R.D. [University of Liverpool, Department of Physics, Oliver Lodge Laboratory, Liverpool (United Kingdom); Konki, J.; Greenlees, P.T.; Pakarinen, J.; Papadakis, P.; Rahkila, P.; Sandzelius, M.; Sorri, J. [University of Jyvaeskylae, Department of Physics, Jyvaeskylae (Finland); Hauschild, K. [Universite Paris-Sud, CSNSM-IN2P3-CNRS, Orsay (France)

    2015-06-15

    The SAGE spectrometer combines a Ge-detector array with a Si detector to allow simultaneous detection of γ-rays and electrons. A comprehensive GEANT4 simulation package of the SAGE spectrometer has been developed with the ability to simulate the expected datasets based on user input files. The measured performance of the spectrometer is compared to the results obtained from the simulations. (orig.)

  12. Effective quantum number for axially symmetric problems

    OpenAIRE

    Trunov, N. N.

    2014-01-01

    We generalize the universal effective quantum number introduced earlier for centrally symmetric problems. The proposed number determines the semiclassical quantization condition for axially symmetric potentials.

  13. Double focussing stigmatic image mass spectrometer

    International Nuclear Information System (INIS)

    The mass spectrometer for the analysis of ions, which occur in matetial pulverisation by a radiation micro probe, contains one lens a 450 spherical condenser lens, from which the ion beam emerhes as a parallel beam, an intermediate shutter, a 900 magnetic field and an outlet shutter. The angle of entry and energy bandwidth can be set independently of each other. An optimum transmission is obtained with the least possible image errors. (DG)

  14. Design of modern high resolution magnetic spectrometers

    International Nuclear Information System (INIS)

    The choice of correcting nonlinear aberrations in high resolution magnetic spectrometers with software or hardware is examined. The ability of raytracing methods, using realistic focal plane detector resolutions, is demonstrated for the S800 spectrograph under construction at the National Superconducting Cyclotron Laboratory (NSCL). Furthermore, Differential Algebraic methods are shown to reproduce the results for accurately known fields at a considerable savings in design time. (Author)

  15. Introduction to Subatomic-Particle Spectrometers

    OpenAIRE

    Kaplan, Daniel M.; Lane, Charles E.; Nelson, Kenneth S.

    1998-01-01

    An introductory review, suitable for the beginning student of high-energy physics or professionals from other fields who may desire familiarity with subatomic-particle detection techniques. Subatomic-particle fundamentals and the basics of particle interactions with matter are summarized, after which we review particle detectors. We conclude with three examples that illustrate the variety of subatomic-particle spectrometers and exemplify the combined use of several detection techniques to cha...

  16. Laser spectrometer of ion mobility

    International Nuclear Information System (INIS)

    The process of ion packet broadening in longitudinal laser spectrometer of ion mobility is studied. The contributions of diffusion, Coulomb and other broadening mechanisms are compared. The resolution of the developed spectrometer is measured (R ∼ 45) in atmospheres of both purified air and pure nitrogen. The dependence of the spectrometer resolution on the drift voltage is studied. The recorded spectra of some explosives with an extremely low pressure of saturated vapors indicate a high sensitivity of this spectrometer (no worse than 10-14 g/cm3)

  17. A spark-chamber spectrometer

    International Nuclear Information System (INIS)

    A programme of developing techniques for the construction and use of spark chambers in high-energy physics experiments has been undertaken. Several methods of construction have been tested and found satisfactory. One method is to cement aluminium plates to frames made from glass or Plexiglas strips. Another is to place the aluminium plates in grooves machined in Plexiglas, forming a ''shelf'' design. A chamber made of rows of wires was successfully operated with a He-alcohol mixture. These chambers can either be filled with gas and sealed, or gas can be passed through them continuously. Chambers have been constructed with plates of various thicknesses ranging from 0.032 in downwards. The operation of the chambers with various spacings between the plates was also investigated. The performance of these chambers, when filled with several different gases (Ne, He, A) and with gas-alcohol mixtures, has been investigated. Several methods of applying high-voltage pulses to the chambers have been attempted. The results of these investigations are presented. Spark chambers placed in a magnetic field can be used in principle to determine the momentum of charged particles and if lead converter-plates are incorporated with them, the resulting system should serve as a gamma-ray spectrometer of high resolution and high efficiency. A magnet with an 18-in useful diameter and a 13000-G field is being fitted with spark chambers, whose performance will be tested with cosmic rays and with an accelerator beam. Results from such tests are presented. (author)

  18. New results from the LASS (Large Aperture Superconducting Solenoid) spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Aston, D.; Awaji, N.; Bienz, T.; Bird, F.; D' Amore, J.; Dunwoodie, W.; Endorf, R.; Fujii, K.; Hayashii, H.; Iwata, S.

    1987-06-22

    New results are presented from analyses of several mesonic and baryonic states containing one or more strange quarks. The data are taken from a high statistics (4 events/nb) study of K p interactions at 11 GeV/c carried out in the LASS Spectrometer at SLAC. New information is reported on the underlying K* states and also evidence for selective coupling of K eta to the K*'s; on the strangeonium members of the axial vector nonets in the K anti K channel; and on evidence for an * state.

  19. A spectrometer for pulsed and continuous electron and photon radiation

    International Nuclear Information System (INIS)

    A few-channel spectrometer for the determination of absolute fluence and energy distributions (spectra) of electrons and photons was developed. It consists of thermoluminescence detectors (TLDs) placed in a stack of different absorbers. From the measured depth dose curve the impinging particle spectra can be derived via deconvolution methods (data evaluation). In mixed radiation fields it is necessary to take into account information in addition to the measured depth dose curve (additional pre-information) for the data evaluation. In addition, a nuclear track detector (CR-39) is implemented in the spectrometer to detect ions and protons. The spectrometer was successfully applied in different areas. (author)

  20. Optical fiber smartphone spectrometer.

    Science.gov (United States)

    Hossain, Md Arafat; Canning, John; Cook, Kevin; Jamalipour, Abbas

    2016-05-15

    An optical fiber-based smartphone spectrometer incorporating an endoscopic fiber bundle is demonstrated. The endoscope allows transmission of the smartphone camera LED light to a sample, removing complications from varying background illumination. The reflected spectra collected from a surface or interface is dispersed onto the camera CMOS using a reflecting diffraction grating. A spectral resolution as low as δλ∼2.0  nm over a bandwidth of Δλ∼250  nm is obtained using a slit width, ωslit=0.7  mm. The instrument has vast potential in a number of industrial applications including agricultural produce analysis. Spectral analysis of apples shows straightforward measurement of the pigments anthocyanins, carotenoid, and chlorophyll, all of which decrease with increasing storage time. PMID:27176971

  1. BNL multiparticle spectrometer software

    International Nuclear Information System (INIS)

    This paper discusses some solutions to problems common to the design, management and maintenance of a large high energy physics spectrometer software system. The experience of dealing with a large, complex program and the necessity of having the program controlled by various people at different levels of computer experience has led us to design a program control structure of mnemonic and self-explanatory nature. The use of this control language in both on-line and off-line operation of the program will be discussed. The solution of structuring a large program for modularity so that substantial changes to the program can be made easily for a wide variety of high energy physics experiments is discussed. Specialized tools for this type of large program management are also discussed

  2. Thermoluminescence emission spectrometer.

    Science.gov (United States)

    Prescott, J R; Fox, P J; Akber, R A; Jensen, H E

    1988-08-15

    A sensitive thermoluminescence (TL) emission spectrometer based on Fourier transform spectroscopy is described. It employs a modified scanning Twyman-Green interferometer with photomultiplier detection in a photon-counting mode. The etendue is 180pi mm(2), and it covers the 350-600-nm wavelength range. The output can be displayed either as a 3-D isometric plot of intensity vs temperature and wavelength, as a contour diagram, or as a conventional TL glow curve of intensity vs temperature. It is sufficiently sensitive to record thermoluminescence spectra of dosimeter phosphors and minerals for thermoluminescence dating at levels corresponding to those found during actual use as radiation monitors or in dating. Examples of actual spectra are given. PMID:20539405

  3. Ultraviolet and infrared aspects of the axial anomaly. I

    International Nuclear Information System (INIS)

    The paper is the first part of a brief review of some perturbative aspects of the Adler-Bell-Jackiw axial anomaly, described in terms of ultraviolet and infrared behavior of the famous VVA triangle graph. Apart from a general overview of the diversified role played by the anomaly in quantum field theory and particle physics, an elementary introduction is presented to the subject of the anomaly, comprehensible to an uninitiated reader with only a basic background in quantum field theory. The ultraviolet aspects of the anomaly are stressed and the topics covered are the following: vector and axial-vector Ward identities for the VVA triangle graph; the anomaly and several ways to derive it, namely the symmetric momentum cut-off and shifting the integration variables in linearly divergent integrals; the Adler-Rosenberg argument; the Pauli-Villars method; and dimensional regularization. (author) 2 figs., 34 refs

  4. Research on design method of spaceborne imaging spectrometer system based on telecentric optical system

    Science.gov (United States)

    Liu, Xiaomei; Liu, Hua

    2015-08-01

    Imaging spectrometer is widely applied in the field of space remote sensing. Dispersion imaging spectrometer with prism or grating is developed rapidly and used widely. It is developed to the direction of high performance and miniaturization, such as large field of view, high resolution, small volume, etc. For meeting the demand of the development, by comparing the characteristics and the situation of development and application about the two kinds of spectrometer, based on the imaging theory of telecentric optical system, the article studied a design method of prism dispersion imaging spectrometer with telecentric Off-axis Three-Mirror imaging system. The instrument designed by using this method has smaller volume and weight than traditional instrument. It overcomes the biggest defect that traditional prism dispersion imaging spectrometer is bigger, increases its advantages in actual use in contrast to grating dispersion imaging spectrometer, and promotes the development and application of prism dispersion imaging spectrometer.

  5. Wilson Loop and the Treatment of Axial Gauge Poles

    OpenAIRE

    Joglekar, Satish D.; Misra, A.

    1999-01-01

    We consider the question of gauge invariance of the Wilson loop in the light of a new treatment of axial gauge propagator proposed recently based on a finite field-dependent BRS (FFBRS) transformation. We remark that as under the FFBRS transformation the vacuum expectation value of a gauge invariant observable remains unchanged, our prescription automatically satisfies the Wilson loop criterion. Further, we give an argument for {\\it direct} verification of the invariance of Wilson loop to O(g...

  6. Modelling of the axial-flow gas laser

    International Nuclear Information System (INIS)

    A mathematical model is advanced for the axial-flow gas laser under the premise that the flow in the cylindrical tube occurs at both small Reynolds number and magnetic Reynolds number, in the presence of free convection heat transfer. Hence the induced magnetic fields may be neglected and perturbation methods are adopted to construct analytical solutions. These solutions are discussed quantitatively. (author). 4 refs, 2 figs

  7. Identification of material parameters using bi-axial machine

    OpenAIRE

    Flores, Paulo; de Montleau, P.; Mathonet, V.; Moureaux, P. (collab.); Habraken, Anne

    2004-01-01

    Experimental testing equipment is built in order to identify material parameters of complex phenomenological constitutive laws. This equipment consists in a bi-axial test machine able to perform plane strain and simple shear tests separately or simultaneously and a Miyauchi simple shear test device; an optical extensometer is used to identify the strain field. The article focus on the validation of the results of this new equipment by comparing with results obtained by standard machines and/o...

  8. Axial anomaly, Dirac sea, and the chiral magnetic effect

    OpenAIRE

    Kharzeev, Dmitri E.

    2010-01-01

    Gribov viewed the axial anomaly as a manifestation of the collective motion of charged fermions with arbitrarily high momenta in the vacuum. In the presence of an external magnetic field and a chirality imbalance, this collective motion becomes directly observable in the form of the electric current - this is the chiral magnetic effect (CME). I give an elementary introduction into the physics of CME, and discuss some recent developments.

  9. A portable scintillation spectrometer for environmental radiation measurements

    International Nuclear Information System (INIS)

    A portable scintillation spectrometer for field use, applicable to the in situ measurements of environmental radiation, has been developed. It consists of a 3 in. spherical NaI (Tl) scintillation detector, an interface and a commercial two channel audio tape recorder. The whole system of the spectrometer weighs 7.3 kg, and can be housed in a small suitcase (''air bag'', 34 x 45 x 21 (cm)). Several examples of its application to environmental radiation measurements are presented. (author)

  10. A contribution to the study of mass-kinetic energy-nuclear charges correlations for fission fragments with the 'Cosi Fan Tutte' spectrometer

    International Nuclear Information System (INIS)

    The present work is devoted to the fragments produced in the neutrons induced fission of 235U, performed with the time of flight-energy spectrometer 'Cosi Fan Tutte' recently built at the neutron high flux reactor of the Laue-Langevin Institute at Grenoble. Mass-kinetic energy-nuclear charge correlations were measured for the light fission fragment group. Nuclear charges were identified for the first time on this spectrometer using the range difference of the fission fragments in an axial field ionisation chamber. The present results are in good agreement with the previous one obtained using the spectrometer 'Lohengrin', which proves the validity of the methods which we developed. In addition, we extend the measurements to higher kinetic energies. The structures which appear in the distributions are attributed to spherical and deformed shell effects in the nascent fragments and to even odd effects. The study of thermal neutron induced fission of 229Th, which is scarcely known, has been started. (author)

  11. Axial Anomaly and the Triality Symmetry of Octonion

    International Nuclear Information System (INIS)

    With an assumption that in the Yang-Mills Lagrangian, a left-handed fermion and a right-handed fermion both expressed as the quaternion makes an octonion, and the gauge field can be treated as self-dual, we calculate the axial current and two vector currents triangle diagram of Bardeen, which yields the contribution of the axial anomaly. The octonion possesses the triality symmetry, and there are 5 symmetry operations Gij and Gijk (ijk = 123), in which mixing of spinors and vectors occur. G23 does not mix vectors and spinors, but mismatch of the spinor and vector fields occurs. Hence, electro magnetic (EM) wave emitted from galaxies transformed by the five transformations would not be detected by EM detectors in our galaxy, and the source would be regarded as dark matter. The axial anomaly appears as a reflection of the symmetry of the matter field and not as a reflection of the symmetry of the pure vacuum, which is consistent with recent arguments on condensates and confinement. (author)

  12. Sensing systems using chip-based spectrometers

    Science.gov (United States)

    Nitkowski, Arthur; Preston, Kyle J.; Sherwood-Droz, Nicolás.; Behr, Bradford B.; Bismilla, Yusuf; Cenko, Andrew T.; DesRoches, Brandon; Meade, Jeffrey T.; Munro, Elizabeth A.; Slaa, Jared; Schmidt, Bradley S.; Hajian, Arsen R.

    2014-06-01

    Tornado Spectral Systems has developed a new chip-based spectrometer called OCTANE, the Optical Coherence Tomography Advanced Nanophotonic Engine, built using a planar lightwave circuit with integrated waveguides fabricated on a silicon wafer. While designed for spectral domain optical coherence tomography (SD-OCT) systems, the same miniaturized technology can be applied to many other spectroscopic applications. The field of integrated optics enables the design of complex optical systems which are monolithically integrated on silicon chips. The form factors of these systems can be significantly smaller, more robust and less expensive than their equivalent free-space counterparts. Fabrication techniques and material systems developed for microelectronics have previously been adapted for integrated optics in the telecom industry, where millions of chip-based components are used to power the optical backbone of the internet. We have further adapted the photonic technology platform for spectroscopy applications, allowing unheard-of economies of scale for these types of optical devices. Instead of changing lenses and aligning systems, these devices are accurately designed programmatically and are easily customized for specific applications. Spectrometers using integrated optics have large advantages in systems where size, robustness and cost matter: field-deployable devices, UAVs, UUVs, satellites, handheld scanning and more. We will discuss the performance characteristics of our chip-based spectrometers and the type of spectral sensing applications enabled by this technology.

  13. Quench anaylsis of MICE spectrometer superconducting solenoid

    Energy Technology Data Exchange (ETDEWEB)

    Kashikhin, Vladimir; Bross, Alan; /Fermilab; Prestemon, Soren; / /LBL, Berkeley

    2011-09-01

    MICE superconducting spectrometer solenoids fabrication and tests are in progress now. First tests of the Spectrometer Solenoid discovered some issues which could be related to the chosen passive quench protection system. Both solenoids do not have heaters and quench propagation relied on the 'quench back' effect, cold diodes, and shunt resistors. The solenoids have very large inductances and stored energy which is 100% dissipated in the cold mass during a quench. This makes their protection a challenging task. The paper presents the quench analysis of these solenoids based on 3D FEA solution of coupled transient electromagnetic and thermal problems. The simulations used the Vector Fields QUENCH code. It is shown that in some quench scenarios, the quench propagation is relatively slow and some areas can be overheated. They describe ways of improving the solenoids quench protection in order to reduce the risk of possible failure.

  14. Data Reduction with the MIKE Spectrometer

    CERN Document Server

    Bernstein, Rebecca A; Prochaska, J Xavier

    2015-01-01

    This manuscript describes the design, usage, and data-reduction pipeline developed for the Magellan Inamori Kyocera Echelle (MIKE) spectrometer used with the Magellan telescope at the Las Campanas Observatory. We summarize the basic characteristics of the instrument and discuss observational procedures recommended for calibrating the standard data products. We detail the design and implementation of an IDL based data-reduction pipeline for MIKE data (since generalized to other echelle spectrometers, e.g. Keck/HIRES, VLT/UVES). This includes novel techniques for flat-fielding, wavelength calibration, and the extraction of echelle spectroscopy. Sufficient detail is provided in this manuscript to enable inexperienced observers to understand the strengths and weaknesses of the instrument and software package and an assessment of the related systematics.

  15. Nuclear magnetic resonance spectrometer and method

    International Nuclear Information System (INIS)

    A nuclear magnetic resonance techniis described that allows simultaneous temperature determination and spectral acquisition. The technique employs a modification of the lock circuit of a varian xl-100 spectrometer which permits accurate measurement of the difference in resonance frequency between a primary lock nucleus and another , secondary, nucleus. The field stabilization function of the main lock circuit is not compromised. A feedback signal having a frequency equal to the frequency difference is substituted for the normal power supply in the spectrometer's existing radio frequency transmitter to modulate that transmitter. Thus, the transmitter's radio frequency signal is enhanced in a frequency corresponding to the resonance peak of the secondary nucleus. Determination of the frequency difference allows the determination of temperature without interference with the observed spectrum. The feedback character of the circuit and the presence of noise make the circuit self-activating

  16. Cryogenic system for a superconducting spectrometer

    International Nuclear Information System (INIS)

    The Heavy Ion Spectrometer System (HISS) relies upon superconducting coils of cryostable, pool boiling design to provide a maximum particle bending field of 3 tesla. This paper describes the cryogenic facility including helium refrigeration, gas management, liquid nitrogen system, and the overall control strategy. The system normally operates with a 4 K heat load of 150 watts; the LN2 circuits absorb an additional 4000 watts. 80K intercept control is by an LSI 11 computer. Total available refrigeration at 4K is 400 watts using reciprocating expanders at the 20K and 4K level. The minicomputer has the capability of optimizing overall utility input cost by varying operating points. A hybrid of pneumatic, analog, and digital control is successful in providing full time unattended operation. The 7m diameter magnet/cryostat assembly is rotatable through 180 degrees to provide a variety of spectrometer orientations

  17. High-resolving mass spectrographs and spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Wollnik, Hermann, E-mail: hwollnik@gmail.com [New Mexico State University, Department of Chemistry & Biochemistry (United States)

    2015-11-15

    Discussed are different types of high resolving mass spectrographs and spectrometers. In detail outlined are (1) magnetic and electric sector field mass spectrographs, which are the oldest systems, (2) Penning Trap mass spectrographs and spectrometers, which have achieved very high mass-resolving powers, but are technically demanding (3) time-of-flight mass spectrographs using high energy ions passing through accelerator rings, which have also achieved very high mass-resolving powers and are equally technically demanding, (4) linear time-of-flight mass spectrographs, which have become the most versatile mass analyzers for low energy ions, while the even higher performing multi-pass systems have only started to be used, (5) orbitraps, which also have achieved remarkably high mass-resolving powers for low energy ions.

  18. High-resolving mass spectrographs and spectrometers

    Science.gov (United States)

    Wollnik, Hermann

    2015-11-01

    Discussed are different types of high resolving mass spectrographs and spectrometers. In detail outlined are (1) magnetic and electric sector field mass spectrographs, which are the oldest systems, (2) Penning Trap mass spectrographs and spectrometers, which have achieved very high mass-resolving powers, but are technically demanding (3) time-of-flight mass spectrographs using high energy ions passing through accelerator rings, which have also achieved very high mass-resolving powers and are equally technically demanding, (4) linear time-of-flight mass spectrographs, which have become the most versatile mass analyzers for low energy ions, while the even higher performing multi-pass systems have only started to be used, (5) orbitraps, which also have achieved remarkably high mass-resolving powers for low energy ions.

  19. Biopolymer mass spectrometer with cryogenic particle detectors

    International Nuclear Information System (INIS)

    A novel type of biopolymer mass spectrometer is proposed for massive proteins, polypeptides and DNA-fragments by replacing standard ionizing detectors with cryogenic particle detectors. The detection efficiency in ionizing detectors decreases rapidly with increasing biopolymer mass owing to the biopolymer's decreasing velocity. Cryogenic particle detectors, however, record the total kinetic energy deposited by the accelerated biopolymer. In a given electric acceleration field, this kinetic energy is independent of mass and depends only on the biopolymer's charged state. Using the intrinsic properties of cryogenic particle detectors and their specific fabrication techniques, a mass spectrometer has been designed specifically for high-throughput DNA-sequencing. The calculated DNA-fragment separation rate would be increased by several orders of magnitude as compared to standard gel-electrophoresis DNA-sequencers. (orig.)

  20. PAC Spectrometer for Condensed Matter Investigation

    CERN Document Server

    Brudanin, V B; Kochetov, O I; Korolev, N A; Milanov, M; Ostrovsky, I V; Pavlov, V N; Salamatin, A V; Timkin, V V; Velichkov, A I; Fomicheva, L N; Tsvyaschenko, A V; Akselrod, Z Z

    2005-01-01

    A four-detector spectrometer of perturbed angular $\\gamma \\gamma $ correlations is developed for investigation of hyperfine interactions in condensed matter. It allows measurements with practically any types of detectors. A unique circuit design involving a specially developed Master PAC unit combined with a computer allows a substantially higher efficiency, reduced setup time and simpler operation in comparison with traditional PAC spectrometers. A cryostat and a high-temperature oven allow measurements in the temperature range from 120 to 1300 K. An encased electromagnet makes it possible to generate a magnetic field up to 2 T on a sample. The measurement system includes a press with a specially designed high-pressure chamber allowing on-line PAC measurements in samples under pressure up to 60 GPa.

  1. The MIRI Medium Resolution Spectrometer calibration pipeline

    CERN Document Server

    Labiano, A; Bailey, J I; Beard, S; Dicken, D; García-Marín, M; Geers, V; Glasse, A; Glauser, A; Gordon, K; Justtanont, K; Klaassen, P; Lahuis, F; Law, D; Morrison, J; Müller, M; Rieke, G; Vandenbussche, B; Wright, G

    2016-01-01

    The Mid-Infrared Instrument (MIRI) Medium Resolution Spectrometer (MRS) is the only mid-IR Integral Field Spectrometer on board James Webb Space Telescope. The complexity of the MRS requires a very specialized pipeline, with some specific steps not present in other pipelines of JWST instruments, such as fringe corrections and wavelength offsets, with different algorithms for point source or extended source data. The MRS pipeline has also two different variants: the baseline pipeline, optimized for most foreseen science cases, and the optimal pipeline, where extra steps will be needed for specific science cases. This paper provides a comprehensive description of the MRS Calibration Pipeline from uncalibrated slope images to final scientific products, with brief descriptions of its algorithms, input and output data, and the accessory data and calibration data products necessary to run the pipeline.

  2. Realisation of a β spectrometer solenoidal and a double β spectrometer at coincidence

    International Nuclear Information System (INIS)

    The two spectrometers have been achieved to tackle numerous problems of nuclear spectrometry. They possess different fields of application that complete themselves. The solenoidal spectrometer permits the determination of the energy limits of β spectra and of their shape; it also permits the determination of the coefficients of internal conversion and reports αK / αL and it is especially efficient for the accurate energy levels of the γ rays by photoelectric effect. The double coincidence spectrometer has been conceived to get a good efficiency in coincidence: indeed, the sum of the solid angles used for the β and γ emission is rather little lower to 4π steradians. To get this efficiency, one should have sacrificed a little the resolution that is lower to the one obtained with the solenoidal spectrometer for a same brightness. Each of the elements of the double spectrometer can also be adapted to the study of angular correlations βγ and e-γ. In this use, it is superior to the thin magnetic lens used up to here. The double spectrometer also permits the survey of the coincidences e-e-, e-β of a equivalent way to a double lens; it can also be consider some adaptation for the survey of the angular correlations e-e-, e-β. Finally, we applied the methods by simple spectrometry and by coincidence spectrometry, to the study of the radiances of the following radioelements: 76As (26 h), 122Sb (2,8 j), 124Sb (60 j), 125Sb (2,7 years). (M.B.)

  3. Axial force measurement for esophageal function testing.

    Science.gov (United States)

    Gravesen, Flemming H; Funch-Jensen, Peter; Gregersen, Hans; Drewes, Asbjørn Mohr

    2009-01-14

    The esophagus serves to transport food and fluid from the pharynx to the stomach. Manometry has been the "golden standard" for the diagnosis of esophageal motility diseases for many decades. Hence, esophageal function is normally evaluated by means of manometry even though it reflects the squeeze force (force in radial direction) whereas the bolus moves along the length of esophagus in a distal direction. Force measurements in the longitudinal (axial) direction provide a more direct measure of esophageal transport function. The technique used to record axial force has developed from external force transducers over in-vivo strain gauges of various sizes to electrical impedance based measurements. The amplitude and duration of the axial force has been shown to be as reliable as manometry. Normal, as well as abnormal, manometric recordings occur with normal bolus transit, which have been documented using imaging modalities such as radiography and scintigraphy. This inconsistency using manometry has also been documented by axial force recordings. This underlines the lack of information when diagnostics are based on manometry alone. Increasing the volume of a bag mounted on a probe with combined axial force and manometry recordings showed that axial force amplitude increased by 130% in contrast to an increase of 30% using manometry. Using axial force in combination with manometry provides a more complete picture of esophageal motility, and the current paper outlines the advantages of using this method. PMID:19132762

  4. Axial force measurement for esophageal function testing

    Institute of Scientific and Technical Information of China (English)

    Flemming H Gravesen; Peter Funch-Jensen; Hans Gregersen; Asbjφrn Mohr Drewes

    2009-01-01

    The esophagus serves to transport food and fluid from the pharynx to the stomach. Manometry has been the "golden standard" for the diagnosis of esophageal motility diseases for many decades. Hence, esophageal function is normally evaluated by means of manometry even though it reflects the squeeze force (force in radial direction) whereas the bolus moves along the length of esophagus in a distal direction. Force measurements in the longitudinal (axial) direction provide a more direct measure of esophageal transport function. The technique used to record axial force has developed from external force transducers over in-vivo strain gauges of various sizes to electrical impedance based measurements. The amplitude and duration of the axial force has been shown to be as reliable as manometry. Normal, as well as abnormal, manometric recordings occur with normal bolus transit, which have been documented using imaging modalities such as radiography and scintigraphy. This inconsistency using manometry has also been documented by axial force recordings. This underlines the lack of information when diagnostics are based on manometry alone. Increasing the volume of a bag mounted on a probe with combined axial force and manometry recordings showed that axial force amplitude increased by 130% in contrast to an increase of 30% using manometry. Using axial force in combination with manometry provides a more complete picture of esophageal motility, and the current paper outlines the advantages of using this method.

  5. VEGAS: VErsatile GBT Astronomical Spectrometer

    Science.gov (United States)

    Bussa, Srikanth; VEGAS Development Team

    2012-01-01

    The National Science Foundation Advanced Technologies and Instrumentation (NSF-ATI) program is funding a new spectrometer backend for the Green Bank Telescope (GBT). This spectrometer is being built by the CICADA collaboration - collaboration between the National Radio Astronomy Observatory (NRAO) and the Center for Astronomy Signal Processing and Electronics Research (CASPER) at the University of California Berkeley.The backend is named as VErsatile GBT Astronomical Spectrometer (VEGAS) and will replace the capabilities of the existing spectrometers. This backend supports data processing from focal plane array systems. The spectrometer will be capable of processing up to 1.25 GHz bandwidth from 8 dual polarized beams or a bandwidth up to 10 GHz from a dual polarized beam.The spectrometer will be using 8-bit analog to digital converters (ADC), which gives a better dynamic range than existing GBT spectrometers. There will be 8 tunable digital sub-bands within the 1.25 GHz bandwidth, which will enhance the capability of simultaneous observation of multiple spectral transitions. The maximum spectral dump rate to disk will be about 0.5 msec. The vastly enhanced backend capabilities will support several science projects with the GBT. The projects include mapping temperature and density structure of molecular clouds; searches for organic molecules in the interstellar medium; determination of the fundamental constants of our evolving Universe; red-shifted spectral features from galaxies across cosmic time and survey for pulsars in the extreme gravitational environment of the Galactic Center.

  6. Spectrometers and Polyphase Filterbanks in Radio Astronomy

    CERN Document Server

    Price, Danny C

    2016-01-01

    This review gives an introduction to spectrometers and discusses their use within radio astronomy. While a variety of technologies are introduced, particular emphasis is given to digital systems. Three different types of digital spectrometers are discussed: autocorrelation spectrometers, Fourier transform spectrometers, and polyphase filterbank spectrometers. Given their growing ubiquity and significant advantages, polyphase filterbanks are detailed at length. The relative advantages and disadvantages of different spectrometer technologies are compared and contrasted, and implementation considerations are presented.

  7. The OPERA muon spectrometers

    International Nuclear Information System (INIS)

    The OPERA experiment will study νμ to ντ oscillations through τ appearance on the 732km long CERN to Gran Sasso baseline. The magnet yokes of the two muon spectrometers are instrumented with 48 planes of high resistivity bakelite Resistive Plate Chambers (RPC) operated in streamer mode. Each plane covers about 70m2. A general introduction to the system installation and commissioning will be given. Four RPC planes were instrumented and the first tests were performed confirming a good behavior of the installed RPCs in terms of intrinsic noise and operating currents. The measured noise maps agree with those obtained in the extensive quality test performed at surface. Counting rates are below 20Hz/m2. Single and multiple cosmic muon tracks were also reconstructed. The estimated efficiency is close to the geometrical limit and the very first measurements of the absolute and differential muon flux are in agreement with the expectations. Finally, a description of the readout electronics and of the slow control system is given

  8. The OPERA muon spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Garfagnini, A. [Padova University and INFN, Padova (Italy)]. E-mail: alberto.garfagnini@pd.infn.it; Bergnoli, A. [Padova University and INFN, Padova (Italy); Brugnera, R. [Padova University and INFN, Padova (Italy); Carrara, E. [Padova University and INFN, Padova (Italy); Ciesielski, R. [Padova University and INFN, Padova (Italy); Dal Corso, F. [Padova University and INFN, Padova (Italy); Dusini, S. [Padova University and INFN, Padova (Italy); Fanin, C. [Padova University and INFN, Padova (Italy); Longhin, A. [Padova University and INFN, Padova (Italy); Stanco, L. [Padova University and INFN, Padova (Italy); Cazes, A. [INFN Laboratori Nazionali di Frascati, Frascati (Italy); Cecchetti, A. [INFN Laboratori Nazionali di Frascati, Frascati (Italy); Di Troia, C. [INFN Laboratori Nazionali di Frascati, Frascati (Italy); Dulach, B. [INFN Laboratori Nazionali di Frascati, Frascati (Italy); Felici, G. [INFN Laboratori Nazionali di Frascati, Frascati (Italy); Mengucci, A. [INFN Laboratori Nazionali di Frascati, Frascati (Italy); Orecchini, D. [INFN Laboratori Nazionali di Frascati, Frascati (Italy); Paoloni, A. [INFN Laboratori Nazionali di Frascati, Frascati (Italy); Spinetti, M. [INFN Laboratori Nazionali di Frascati, Frascati (Italy); Terranova, F. [INFN Laboratori Nazionali di Frascati, Frascati (Italy); Ventura, M. [INFN Laboratori Nazionali di Frascati, Frascati (Italy); Votano, L. [INFN Laboratori Nazionali di Frascati, Frascati (Italy); Candela, A. [INFN Laboratori Nazionali del Gran Sasso, Assergi (Italy); D' Incecco, M. [INFN Laboratori Nazionali del Gran Sasso, Assergi (Italy); Gustavino, C. [INFN Laboratori Nazionali del Gran Sasso, Assergi (Italy); Lindozzi, M. [INFN Laboratori Nazionali del Gran Sasso, Assergi (Italy)

    2007-03-01

    The OPERA experiment will study {nu}{sub {mu}} to {nu}{sub {tau}} oscillations through {tau} appearance on the 732km long CERN to Gran Sasso baseline. The magnet yokes of the two muon spectrometers are instrumented with 48 planes of high resistivity bakelite Resistive Plate Chambers (RPC) operated in streamer mode. Each plane covers about 70m{sup 2}. A general introduction to the system installation and commissioning will be given. Four RPC planes were instrumented and the first tests were performed confirming a good behavior of the installed RPCs in terms of intrinsic noise and operating currents. The measured noise maps agree with those obtained in the extensive quality test performed at surface. Counting rates are below 20Hz/m{sup 2}. Single and multiple cosmic muon tracks were also reconstructed. The estimated efficiency is close to the geometrical limit and the very first measurements of the absolute and differential muon flux are in agreement with the expectations. Finally, a description of the readout electronics and of the slow control system is given.

  9. Axial length variability in cataract surgery

    International Nuclear Information System (INIS)

    To determine the mean axial length and biometric measures in patients undergoing cataract surgery and further compare the variability of axial length between the gender and with age. Study Design: Cross-sectional observational study. Place and Duration of Study: Eye Unit I, Department of Ophthalmology, Liaquat University of Medical and Health Sciences, Hyderabad, Pakistan from January 2010 to December 2012. Methodology: All patients referred for cataract surgery were assessed. The study included 886 eyes which were straightforward cataract cases with no other ocular problem. The data was collected for axial length, keratometric values and Intra-Ocular Lens (IOL) power prior to cataract surgery. The collected data was then analyzed using SPSS version 19 for windows software. Results: Gender based comparison showed significant difference in age, axial length, keratometric values and IOL power between the two groups (p=0.000). 86% of the eyes had an axial length between 21.00 mm and 23.99 mm. In univariate analysis there was significant (p=0.000) relation between overall age and axial length. The keratometric values ranged between 36.75 D and 52.50 D. Majority of the IOL powers ranged between 20.00 D and 23.00 D. Conclusion: The mean axial length of patients undergoing cataract surgery was 22.96 +- 1.04 mm, was comparable to Indian and Chinese population but shorter than the Western population. Females had shorter axial lengths, similar to other studies. Axial length was positively associated with age among the females, the cause of which is yet to be determined. (author)

  10. Axially Loaded Behavior of Driven PC Piles

    Science.gov (United States)

    Hsu, Shih-Tsung

    2010-05-01

    To obtain a fair load-settlement curve of a driven pile, and to evaluate the ultimate pile capacity more accurately, a numerical model was created to simulate the ground movements during a pile being driven. After the procedure, the axially loaded behaviors of the piles in silty sand were analyzed. The numerical results are compared with those results by full scale pile load tests. It was found, although the loads added on the tested piles are different from those by the numerical analyses which applied displacement increments on piles, the load-settlement behaviors of piles calculated from the numerical model were close to those measured from field tests before the piles stressed to peak. Total load, shaft friction, and point bearing do not reach peak values at the same pile settlement; furthermore, the point bearing slowly increases all the while, with no peak. However, the point bearing only contributes 10˜20% of ultimate pile capacity. No matter which relative density of silty sand, pile diameter, and pile length increased, ultimate pile capacity increased as well.

  11. Associated Particle Tagging (APT) in Magnetic Spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, David V.; Baciak, James E.; Stave, Sean C.; Chichester, David; Dale, Daniel; Kim, Yujong; Harmon, Frank

    2012-10-16

    Summary In Brief The Associated Particle Tagging (APT) project, a collaboration of Pacific Northwest National Laboratory (PNNL), Idaho National Laboratory (INL) and the Idaho State University (ISU)/Idaho Accelerator Center (IAC), has completed an exploratory study to assess the role of magnetic spectrometers as the linchpin technology in next-generation tagged-neutron and tagged-photon active interrogation (AI). The computational study considered two principle concepts: (1) the application of a solenoidal alpha-particle spectrometer to a next-generation, large-emittance neutron generator for use in the associated particle imaging technique, and (2) the application of tagged photon beams to the detection of fissile material via active interrogation. In both cases, a magnetic spectrometer momentum-analyzes charged particles (in the neutron case, alpha particles accompanying neutron generation in the D-T reaction; in the tagged photon case, post-bremsstrahlung electrons) to define kinematic properties of the relevant neutral interrogation probe particle (i.e. neutron or photon). The main conclusions of the study can be briefly summarized as follows: Neutron generator: • For the solenoidal spectrometer concept, magnetic field strengths of order 1 Tesla or greater are required to keep the transverse size of the spectrometer smaller than 1 meter. The notional magnetic spectrometer design evaluated in this feasibility study uses a 5-T magnetic field and a borehole radius of 18 cm. • The design shows a potential for 4.5 Sr tagged neutron solid angle, a factor of 4.5 larger than achievable with current API neutron-generator designs. • The potential angular resolution for such a tagged neutron beam can be less than 0.5o for modest Si-detector position resolution (3 mm). Further improvement in angular resolution can be made by using Si-detectors with better position resolution. • The report documents several features of a notional generator design incorporating the

  12. Adaptive Computed Tomography Imaging Spectrometer Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The present proposal describes the development of an adaptive Computed Tomography Imaging Spectrometer (CTIS), or "Snapshot" spectrometer which can...

  13. Novel Micro Fourier Transform Spectrometers

    Institute of Scientific and Technical Information of China (English)

    KONG Yan-mei; LIANG Jing-qiu; LIANG Zhong-zhu; WANG-Bo; ZHANG Jun

    2008-01-01

    The miniaturization of spectrometer opens a new application area with real-time and on-site measurements. The Fourier transform spectrometer(FTS) is much attractive considering its particular advantages among the approaches. This paper reviews the current status of micro FTS in worldwide and describes its developments; In addition, analyzed are the key problems in designing and fabricating FTS to be settled during the miniaturization. Finally, a novel model of micro FTS with no moving parts is proposed and analyzed, which may provide new concepts for the design of spectrometers.

  14. Vector modeling and track simulation in axial turn-milling motion

    Institute of Scientific and Technical Information of China (English)

    JIANG Zeng-hui; JIA Chun-de

    2005-01-01

    Through vector analysis the kinetic vector model is built in a machining cylinder surface through axial turn-milling. When building a kinetic vector model in the machining field, machining through axial turn-milling and using equilateral triangles and square prism surfaces, the kinetic vector model is given any equilateral polygon prismic surface. Kinetic tracks are simulated through these kinetic models respectively, thus it can be seen that the axial turn-milling is a very effective method in manufacturing any equilateral, polygon, prismic surface.

  15. Circular Polarization of Periodic Leaky-Wave Antennas with Axial Asymmetry: Theoretical Proof and Experimental Demonstration

    CERN Document Server

    Otto, Simon; Al-Bassam, Amar; Rennings, Andreas; Solbach, Klaus; Caloz, Christophe

    2013-01-01

    The paper includes two contributions. First, it proves that the series and shunt radiation components, corresponding to longitudinal and transversal electric fields, respectively, are always in quadrature-phase in axially asymmetric periodic leaky-wave antennas (LWAs), so that these antennas are inherently circularly polarized. This fact is theoretically proven and experimentally illustrated by two case-study examples, a composite right/left-handed (CRLH) LWA and a series-fed patch (SFP) LWA. Second, it shows (for the case of the SFP LWA) that the axial ratio is controlled and minimized by the degree of axial asymmetry.

  16. HTS axial flux induction motor with analytic and FEA modeling

    International Nuclear Information System (INIS)

    Highlights: •A high temperature superconductor axial flux induction motor and a novel maglev scheme are presented. •Analytic method and finite element method have been adopted to model the motor and to calculate the force. •Magnetic field distribution in HTS coil is calculated by analytic method. •An effective method to improve the critical current of HTS coil is presented. •AC losses of HTS coils in the HTS axial flux induction motor are estimated and tested. -- Abstract: This paper presents a high-temperature superconductor (HTS) axial-flux induction motor, which can output levitation force and torque simultaneously. In order to analyze the character of the force, analytic method and finite element method are adopted to model the motor. To make sure the HTS can carry sufficiently large current and work well, the magnetic field distribution in HTS coil is calculated. An effective method to improve the critical current of HTS coil is presented. Then, AC losses in HTS windings in the motor are estimated and tested

  17. HTS axial flux induction motor with analytic and FEA modeling

    Energy Technology Data Exchange (ETDEWEB)

    Li, S., E-mail: alexlee.zn@gmail.com; Fan, Y.; Fang, J.; Qin, W.; Lv, G.; Li, J.H.

    2013-11-15

    Highlights: •A high temperature superconductor axial flux induction motor and a novel maglev scheme are presented. •Analytic method and finite element method have been adopted to model the motor and to calculate the force. •Magnetic field distribution in HTS coil is calculated by analytic method. •An effective method to improve the critical current of HTS coil is presented. •AC losses of HTS coils in the HTS axial flux induction motor are estimated and tested. -- Abstract: This paper presents a high-temperature superconductor (HTS) axial-flux induction motor, which can output levitation force and torque simultaneously. In order to analyze the character of the force, analytic method and finite element method are adopted to model the motor. To make sure the HTS can carry sufficiently large current and work well, the magnetic field distribution in HTS coil is calculated. An effective method to improve the critical current of HTS coil is presented. Then, AC losses in HTS windings in the motor are estimated and tested.

  18. New Anomaly of the Axial-Vector Current

    Institute of Scientific and Technical Information of China (English)

    HE Han-Xin

    2001-01-01

    By computing the axial-vector current operator equation, we find the anomalous axial-vector curl equation besides the well-known anomalous axial-vector divergence equation (the Adler-Bell-Jackiw anomaly) and discuss its implication.``

  19. Investigation of Valve Plate in Water Hydraulic Axial Piston Motor

    Institute of Scientific and Technical Information of China (English)

    聂松林; 李壮云; 等

    2002-01-01

    This paper has introduced the developments of water hydraulic axial piston equipments.According to the effects of physicochemical properties of water on water hydraulic components,a novel valve plate for water hydraulic axial motor has been put forward,whose moment exerted by the fluid field between valve plate and bearing plate is balanced entirely.The material screening experiment of valve plate is done on the test rig.Through numerical simulation the effects of some geometry parameters on the performance of water hydraulic motor have been studied.The silencing grooves on the valve plate in water hydraulic motor can reduce the pressure shock and the occurrence of cavitation effectively.It is evident that the appropriate structure should change the wear status between matching paris and reduces the wear and specific pressure of the matching pairs.The specimen with the new type valve plate is used in a tool system.

  20. Automated transportable mass spectrometer

    International Nuclear Information System (INIS)

    The need has been identified for a Mass Spectrometer (MS) which can be conveniently transported among several facilities for rapid verification of the isotopic composition of Special Nuclear Material. This requirement for a light weight, transportable MS for U and Pu mass analysis was met by deleting the gas chromatograph (GC) portions of a Hewlett-Packard (H-P) Model 5992 Quadrupole GCMS and substituting a vacuum lock sample entry system. A programmable power supply and vacuum gauge were added and circuitry modifications were made to enable use of the supplied software. The single rhenium filament plug-in source is loaded with either a nominal microliter of sample solution and evaporated, or with a prepared resin bead. Using a resin bead in a specially dimpled filament, copious sensitivity is obtained with 30 nanogram uranium samples. After sample insertion the analysis is completely controlled by an H-P Model 9825 calculator. Source vacuum of 2 x 10-7 torr or better is regained within 2 minutes after sample insertion, and total time for a complete analysis is about 7 minutes. Accuracy is better than 1% for isotope ratios less than 20 and better than 2% for ratios of 100. Ions are accelerated at about 1.8 volts into the mass filter which has pole pieces of hyperbolic cross section. Collection is by a Galileo Channeltron multiplier into a log preamp. During a normal run, 1.4 x 106 data point are observed and averaged. Weight of the instrument excluding the calculator is 88 Kg which allows relatively easy transportation over short distances by two persons. The instrument can be carried into a facility and be ready to analyze samples in less than 3 hours

  1. High energy electron crystal spectrometer

    International Nuclear Information System (INIS)

    A spectrometer has been developed to measure relativistic electrons produced in different types of plasmas, such as tokamak plasmas and laser produced plasmas. The spectrometer consists of nine Y2SiO5:Ce crystals, which are shielded by stainless steel filters. The absolute calibration of the spectrometer was performed at the superconducting electron linear accelerator Electron Linac for beams with high Brilliance and low Emittance. The spectrometer can provide information about energy distribution of electrons and their numbers for the energy range between 4 and 30 MeV. The spectrum is analyzed by means of the Monte Carlo three-dimensional GEANT4 code. An energy resolution of about 10% is achieved.

  2. An antimatter spectrometer in space

    International Nuclear Information System (INIS)

    We discuss a simple magnetic spectrometer to be installed on a satellite or space station. The purpose of this spectrometer is to search for primordial antimatter to the level of antimatter/matter ∼10-9, improving the existing limits obtained with balloon flights by a factor of 104 to 105. The design of the spectrometer is based on an iron-free, Nd-Fe-B permanent magnet, scintillation counters, drift tubes, and silicon or time projection chambers. Different design options are discussed. Typically, the spectrometer has a weight of about 2 tons and an acceptance of about 1.0 m2 sr. The availability of the new Nd-Fe-B material makes it possible for the first time to put a magnet into space economically and reliably. ((orig.))

  3. Axial Thermal Rotation of Slender Rods

    Science.gov (United States)

    Li, Dichuan; Fakhri, Nikta; Pasquali, Matteo; Biswal, Sibani Lisa

    2011-05-01

    Axial rotational diffusion of rodlike polymers is important in processes such as microtubule filament sliding and flagella beating. By imaging the motion of small kinks along the backbone of chains of DNA-linked colloids, we produce a direct and systematic measurement of axial rotational diffusivity of rods both in bulk solution and near a wall. The measured diffusivities decrease linearly with the chain length, irrespective of the distance from a wall, in agreement with slender-body hydrodynamics theory. Moreover, the presence of small kinks does not affect the chain’s axial diffusivity. Our system and measurements provide insights into fundamental axial diffusion processes of slender objects, which encompass a wide range of entities including biological filaments and linear polymer chains.

  4. Numerical Study on the Characteristics of Pressure Fluctuations in an Axial-Flow Water Pump

    OpenAIRE

    Zhi-Jun Shuai; Wan-You Li; Xiang-Yuan Zhang; Chen-Xing Jiang; Feng-Chen Li

    2014-01-01

    Flow induced vibration due to the dynamics of rotor-stator interaction in an axial-flow pump is one of the most damaging vibration sources to the pump components, attached pipelines, and equipment. Three-dimensional unsteady numerical simulations were conducted on the complex turbulent flow field in an axial-flow water pump, in order to investigate the flow induced vibration problem. The shear stress transport (SST) k-ω model was employed in the numerical simulations. The fast Fourier transfo...

  5. Polarimetric spectrometer for Italian Radiotelescopes .

    Science.gov (United States)

    Russo, A.

    A new spectrometer has been designed and tested at the Radioastronomy Laboratory of Arcetri Astrophysical Observatory. It provides a resolution of 4096 spectral points over a bandwidth selectable between 0.5 and 125 MHz. It can analyze up to 8 independent signals with full polarimetric capabilities. This spectrometer can be used as back-end for a 7 channels double polarization radio receiver,working in the frequency range 18-26 GHz, implemented in the same laboratory.

  6. Optical Design of a Compact Imaging Spectrometer for Planetary Mineralogy

    Science.gov (United States)

    Mouroulis, Pantazis; Sellar, R. Glenn; Wilson, Daniel W.; Shea, James J.; Green, Robert O.

    2007-01-01

    We present the design of a compact, wide-angle pushbroom imaging spectrometer suitable for exploration of solar system bodies from low orbit. The spectrometer is based on a single detector array with a broadband response that covers the range 400 to 3000 nm and provides a spectral sampling of 10 nm. The telescope has a 24-deg field of view with 600 spatially resolved elements (detector pixels). A specially designed convex diffraction grating permits optimization of the signal-to-noise ratio through the entire spectral band. Tolerances and design parameters permit the achievement of high uniformity of response through field and wavelength. The spectrometer performance is evaluated in terms of predicted spectral and spatial response functions and from the point of view of minimizing their variation through field and wavelength. The design serves as an example for illustrating the design principles specific to this type of system.

  7. Computer axial tomography in geosciences

    International Nuclear Information System (INIS)

    Computer Axial Tomography (CAT) is one of the most adequate non-invasive techniques for the investigation of the internal structure of a large category of objects. Initially designed for medical investigations, this technique, based on the attenuation of X- or gamma-ray (and in some cases neutrons), generates digital images which map the numerical values of the linear attenuation coefficient of a section or of the entire volume of the investigated sample. Shortly after its application in medicine, CAT has been successfully used in archaeology, life sciences, and geosciences as well as for the industrial materials non-destructive testing. Depending on the energy of the utilized radiation as well as on the effective atomic number of the sample, CAT can provide with a spatial resolution of 0.01 - 0.5 mm, quantitative as well as qualitative information concerning local density, porosity or chemical composition of the sample. At present two types of axial Computer Tomographs (CT) are in use. One category, consisting of medical as well as industrial CT is equipped with X-ray tubes while the other uses isotopic gamma-ray sources. CT provided with intense X-ray sources (equivalent to 12-15 kCi or 450-550 TBq) has the advantage of an extremely short running time (a few seconds and even less) but presents some disadvantages known as beam hardening and absorption edge effects. These effects, intrinsically related to the polychromatic nature of the X-rays generated by classical tubes, need special mathematical or physical corrections. A polychromatic X-ray beam can be made almost monochromatic by means of crystal diffraction or by using adequate multicomponent filters, but these devices are costly and considerably diminish the output of X-ray generators. In the case of CT of the second type, monochromatic gamma-rays generated by radioisotopic sources, such as 169 Yb (50.4 keV), 241 Am (59 keV), 192 Ir (310.5 and 469.1 keV ) or 137 Cs (662.7 keV), are used in combination with

  8. Nonperturbative features of the axial current

    CERN Document Server

    Kopeliovich, B Z; Siddikov, M

    2013-01-01

    In this paper we study the nonperturbative structure of the axial current and evaluate the two-point distribution amplitudes $\\int d\\xi\\, e^{-iq...\\xi}$ in the framework of the instanton vacuum model in the leading order in $\\mathcal{O}(N_{c})$. We perform a direct numerical test of the relations between the axial current and the pion distribution amplitudes, imposed by PCAC, and found excellent agreement.

  9. Axial Vircator for Electronic Warfare Applications

    OpenAIRE

    L. Drazan; R. Vrana

    2009-01-01

    This paper deals with a high power microwave generator with virtual cathode – vircator in axial release for electronic warfare applications. The classification of directed energy weapons microwave (DEWM) is introduced together with basic block diagrams of a particular class of DEWM. In the paper, methods for designing vircator pulsed power supply, axial vircator structure, measurement methods and experimental results are presented. The vircator in electromagnetic ammunition is powered b...

  10. Nonperturbative Aspects of Axial Vector Vertex

    Institute of Scientific and Technical Information of China (English)

    ZONG Hong-Shi; CHEN Xiang-Song; WANG Fan; CHANG Chao-Hsi; ZHAO En-Guang

    2002-01-01

    It is shown how the axial vector current of current quarks is related to that of constituent quarks within the framework of the global color symmetry model.Gluon dressing of the axial vector vertex and the quark self-energy functions are described by the inhomogeneous Bethe-Salpeter equation in the ladder approximation and the Schwinger Dyson equation in the rainbow approximation,respectively.

  11. The Design and Construction of the MICE Spectrometer Solenoids

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Bert; Wahrer, Bob; Taylor, Clyde; Xu, L.; Chen, J. Y.; Wang, M.; Juang, Tiki; Zisman, Michael S.; Virostek, Steve P.; Green, Michael A.

    2008-08-02

    The purpose of the MICE spectrometer solenoid is to provide a uniform field for a scintillating fiber tracker. The uniform field is produced by a long center coil and two short end coils. Together, they produce 4T field with a uniformity of better than 1% over a detector region of 1000 mm long and 300 mm in diameter. Throughout most of the detector region, the field uniformity is better than 0.3%. In addition to the uniform field coils, we have two match coils. These two coils can be independently adjusted to match uniform field region to the focusing coil field. The coil package length is 2544 mm. We present the spectrometer solenoid cold mass design, the powering and quench protection circuits, and the cryogenic cooling system based on using three cryocoolers with re-condensers.

  12. Calibration and intercomparison of neutron moderation spectrometers

    International Nuclear Information System (INIS)

    Results have been reported of comparative measurements of neutron fields from bare PuBe and Cf sources using multisphere (Bonner) spectrometers. The experiments were carried out by the Institute of Biophysics and Nuclear Medicine at Charles University in Prague and the National Board for Atomic Safety and Radiation Protection in Berlin. Both sides agreed upon uniform measuring conditions and calibration factors thus rendering possible the comparability of the dosimetric parameters which have been determined and verified, respectively, to an accuracy of ± 10%. 20 refs., 10 tabs., 2 figs. (author)

  13. The crystal barrel spectrometer at LEAR

    International Nuclear Information System (INIS)

    The Crystal Barrel spectrometer used at LEAR, CERN to study the products of anti pp and anti pd annihilations is described. A 1380 element array of CsI crystals measures photons from the decay of π0, η, η' and ω mesons. A segmented drift chamber in a 1.5 T magnetic field is used to identify and measure charged particles. A fast on-line trigger on charged and neutral multiplicities and on the invariant mass of secondary particles is available. The performance of the detector is discussed. (orig.)

  14. ABERRATIONS MINIMIZATION FOR IMPROVING CHARACTERISTICS OF COMPACT HIGH-APERTURE DISPERSIVE SPECTROMETERS

    Directory of Open Access Journals (Sweden)

    E. S. Voropay

    2015-04-01

    Full Text Available Schemes of high-aperture and compact optical spectrometers and giperspectrometer with minimized aberrations are presented. In the first scheme usage of inclined plane-parallel plate allows decreasing of astigmatism. In the second scheme off-axis aberrations are practically removed due to axial propagation of light. For giperspectrometer narrowing of light propagation angle through the object lens and turning the light out of dispersion plane lead to minimizing of picture aberrations.

  15. A wide bandpass low energy electron spectrometer

    International Nuclear Information System (INIS)

    We have developed a high efficiency, wide bandpass solenoid spectrometer for the detection of electrons between 1 and 20 keV. The apparatus utilizes baffles to impose minimum and maximum constraints on the radii of the electron trajectories, and therefore on the component of their momentum perpendicular to the magnetic field. Electric fields parallel to the magnetic field and time-of-flight information are used to constrain the electron's momentum component along the magnetic axis. A microchannel plate detects the electrons with high efficiency and provides fast timing. The performance of the apparatus was studied through a comparison between binary encounter approximation (BEA) calculations and measurements of delta-electron emission in 5 MeV proton collisions with thin solid carbon targets. (orig.)

  16. Axial quadrupole phase of a uniaxial spin-1 magnet

    International Nuclear Information System (INIS)

    The axial quadrupole phase of uniaxial spin-1 magnet in an external magnetic field has been investigated. The case of magnetic system with the most general form of single‐ion anisotropy and anisotropic biquadratic exchange interaction is considered. It is shown that the relative magnetization in the molecular field approximation does not depend on temperature and linearly increases with external magnetic field. Two branches of the spin excitation spectrum are determined. The boundary between the axial quadrupole and angular phases is defined by the condition for softening of the spectrum. The critical temperature of the corresponding phase transition considerably depends on the anisotropy constants of the biquadratic exchange interaction. - Highlights: • Quadrupole phase of uniaxial spin-1 magnet in external magnetic field are studied. • Influence of the anisotropic biquadratic exchange interaction is examined. • It is shown that the relative magnetization does not depend on temperature. • Two branches of the spin excitation spectrum are determined. • Dependence of critical temperature from anisotropy constants are built

  17. Penning discharge in the KATRIN pre-spectrometer

    Science.gov (United States)

    Fränkle, F. M.; Glück, F.; Valerius, K.; Bokeloh, K.; Beglarian, A.; Bonn, J.; Bornschein, L.; Drexlin, G.; Habermehl, F.; Leber, M. L.; Osipowicz, A.; Otten, E. W.; Steidl, M.; Thümmler, T.; Weinheimer, C.; Wilkerson, J. F.; Wolf, J.; Zadorozhny, S. V.

    2014-07-01

    The KArlsruhe TRItium Neutrino (KATRIN) experiment is a next-generation, large-scale tritium β-decay experiment to determine the neutrino mass by investigating the kinematics of tritium β-decay with a sensitivity of 200 meV/c2 using the MAC-E filter technique. In order to reach this sensitivity a low background level of 10-2 counts per second (cps) is required. A major background concern in MAC-E filters is the presence of Penning traps. A Penning trap is a special configuration of electromagnetic fields that allows the storage of electrically charged particles. This paper describes the mechanism of Penning discharges and the corresponding measurements performed at the test setup of the KATRIN pre-spectrometer. These investigations led to the conclusion that the observed electric breakdown, strong discharges and extremely large background rates were due to discharges caused by Penning traps located at both ends of the pre-spectrometer. Furthermore, the paper describes the design of a new set of electrodes (modified ground electrodes and new ``anti-Penning'' electrodes) to successfully remove these traps. After the installation of these electrodes in the pre-spectrometer, the measurements confirmed that the strong Penning discharges disappeared. The experience gained from the pre-spectrometer was used to design the electrode system of the main spectrometer. Recent measurements with the main spectrometer showed no indications of Penning trap related backgrounds.

  18. A mobile Magnetic Sensor Unit for the KATRIN Main Spectrometer

    CERN Document Server

    Osipowicz, A; Letnev, J; Marte, P; Müller, A; Spengler, A; Unru, A; 10.1088/1748-0221/7/06/T06002

    2012-01-01

    The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to measure the electron neutrino mass with an unprecedented sensitivity of 0.2 eV/c2, using b decay electrons from tritium decay. For the control of magnetic field in the main spectrometer area of the KATRIN experiment a mobile magnetic sensor unit is constructed and tested at the KATRIN main spectrometer site. The unit moves on inner rails of the support structures of the low field shaping coils which are arranged along the the main spectrometer. The unit propagates on a caterpillar drive and contains an electro motor, battery pack, board electronics, 2 triaxial flux gate sensors and 2 inclination senors. During operation all relevant data are stored on board and transmitted to the master station after the docking station is reached.

  19. Controllable rectification of the axial expansion in the thermally driven artificial muscle

    Science.gov (United States)

    Yue, Donghua; Zhang, Xingyi; Yong, Huadong; Zhou, Jun; Zhou, You-He

    2015-09-01

    At present, the concept of artificial muscle twisted by polymers or fibers has become a hot issue in the field of intelligent material research according to its distinguishing advantages, e.g., high energy density, large-stroke, non-hysteresis, and inexpensive. The axial thermal expansion coefficient is an important parameter which can affect its demanding applications. In this letter, a device with high accuracy capacitive sensor is constructed to measure the axial thermal expansion coefficient of the twisted carbon fibers and yarns of Kevlar, and a theoretical model based on the thermal elasticity and the geometrical features of the twisted structure are also presented to predict the axial expansion coefficient. It is found that the calculated results take good agreements with the experimental data. According to the present experiment and analyses, a method to control the axial thermal expansion coefficient of artificial muscle is proposed. Moreover, the mechanism of this kind of thermally driven artificial muscle is discussed.

  20. Metrology for terahertz time-domain spectrometers

    Science.gov (United States)

    Molloy, John F.; Naftaly, Mira

    2015-12-01

    In recent years the terahertz time-domain spectrometer (THz TDS) [1] has emerged as a key measurement device for spectroscopic investigations in the frequency range of 0.1-5 THz. To date, almost every type of material has been studied using THz TDS, including semiconductors, ceramics, polymers, metal films, liquid crystals, glasses, pharmaceuticals, DNA molecules, proteins, gases, composites, foams, oils, and many others. Measurements with a TDS are made in the time domain; conversion from the time domain data to a frequency spectrum is achieved by applying the Fourier Transform, calculated numerically using the Fast Fourier Transform (FFT) algorithm. As in many other types of spectrometer, THz TDS requires that the sample data be referenced to similarly acquired data with no sample present. Unlike frequency-domain spectrometers which detect light intensity and measure absorption spectra, a TDS records both amplitude and phase information, and therefore yields both the absorption coefficient and the refractive index of the sample material. The analysis of the data from THz TDS relies on the assumptions that: a) the frequency scale is accurate; b) the measurement of THz field amplitude is linear; and c) that the presence of the sample does not affect the performance characteristics of the instrument. The frequency scale of a THz TDS is derived from the displacement of the delay line; via FFT, positioning errors may give rise to frequency errors that are difficult to quantify. The measurement of the field amplitude in a THz TDS is required to be linear with a dynamic range of the order of 10 000. And attention must be given to the sample positioning and handling in order to avoid sample-related errors.

  1. Optimization of residual heat removal pump axial thrust and axial bearing

    Energy Technology Data Exchange (ETDEWEB)

    Schubert, F.

    1996-12-01

    The residual heat removal (RHR) pumps of German 1300 megawatt pressurized-water reactor (PWR) power plants are of the single stage end suction type with volute casing or with diffuser and forged circular casing. Due to the service conditions the pumps have to cover the full capacity range as well as a big variation in suction static pressure. This results in a big difference in the axial thrust that has to be borne by the axial bearing. Because these pumps are designed to operate without auxiliary systems (things that do not exist can not fail), they are equipped with antifriction bearings and sump oil lubrication. To minimize the heat production within the bearing casing, a number of PWR plants have pumps with combined axial/radial bearings of the ball type. Due to the fact that the maximum axial thrust caused by static pressure and hydrodynamic forces on the impeller is too big to be borne by that type of axial bearing, the impellers were designed to produce a hydrodynamic axial force that counteracts the static axial force. Thus, the resulting axial thrust may change direction when the static pressure varies.

  2. Design of and data reduction from compact Thomson parabola spectrometers

    Science.gov (United States)

    Morrison, J. T.; Willis, C.; Freeman, R. R.; Van Woerkom, L.

    2011-03-01

    Thomson parabola spectrometers are used to characterize MeV ion beams produced in high intensity laser interactions. These spectrometers disperse multiple ion species according to their charge to mass ratio through the use of parallel electric and magnetic fields. Analytical solutions for ion deflection in electric and magnetic fields have been used to extract ion spectra with the assumption that fringing effects are negligible. Experimental space restrictions and dynamic range requirements necessitate designs that stress the analytical assumptions. Depending on design parameters, the error in the analytical assumption can be comparable to the energy resolution. Estimates are provided to approximate the error on the total ion deflection. A method for modeling ion trajectories including fringing effects is presented using software freely available or in common use. The magnetostatic fields are modeled in 3D, including material properties of nearby magnetic materials using RADIA. Electrostatic fields are modeled in 2D for a spectrometer implementing angled plates using the partial differential equation toolbox in MATLAB®. Using these models to calculate the ion trajectory allows for analysis of a Thomson parabola spectrometer with an arbitrary field configuration.

  3. Polarization converters based on axially symmetric twisted nematic liquid crystal.

    Science.gov (United States)

    Ko, Shih-Wei; Ting, Chi-Lun; Fuh, Andy Y-G; Lin, Tsung-Hsien

    2010-02-15

    An axially symmetric twisted nematic liquid crystal (ASTNLC) device, based on axially symmetric photoalignment, was demonstrated. Such an ASTNLC device can convert axial (azimuthal) to azimuthal (axial) polarization. The optical properties of the ASTNLC device are analyzed and found to agree with simulation results. The ASTNLC device with a specific device can be adopted as an arbitrary axial symmetric polarization converter or waveplate for axially, azimuthally or vertically polarized light. A design for converting linear polarized light to axially symmetric circular polarized light is also demonstrated. PMID:20389369

  4. Improving the lattice axial vector current

    CERN Document Server

    Horsley, R; Perlt, H; Rakow, P E L; Schierholz, G; Schiller, A; Zanotti, J M

    2015-01-01

    For Wilson and clover fermions traditional formulations of the axial vector current do not respect the continuum Ward identity which relates the divergence of that current to the pseudoscalar density. Here we propose to use a point-split or one-link axial vector current whose divergence exactly satisfies a lattice Ward identity, involving the pseudoscalar density and a number of irrelevant operators. We check in one-loop lattice perturbation theory with SLiNC fermion and gauge plaquette action that this is indeed the case including order $O(a)$ effects. Including these operators the axial Ward identity remains renormalisation invariant. First preliminary results of a nonperturbative check of the Ward identity are also presented.

  5. Axial instability of rotating relativistic stars

    CERN Document Server

    Friedman, J L; Friedman, John L.; Morsink, Sharon M.

    1998-01-01

    Perturbations of rotating relativistic stars can be classified by their behavior under parity. For axial perturbations (r-modes), initial data with negative canonical energy is found with angular dependence $e^{im\\phi}$ for all values of $m\\geq 2$ and for arbitrarily slow rotation. This implies instability (or marginal stability) of such perturbations for rotating perfect fluids. This low $m$-instability is strikingly different from the instability to polar perturbations, which sets in first for large values of $m$. The timescale for the axial instability appears, for small angular velocity $\\Omega$, to be proportional to a high power of $\\Omega$. As in the case of polar modes, viscosity will again presumably enforce stability except for hot, rapidly rotating neutron stars. This work complements Andersson's numerical investigation of axial modes in slowly rotating stars.

  6. The axial distribution of reactivity coefficients

    International Nuclear Information System (INIS)

    The purpose of the present work is to investigate the correlation of the axial distributions of the different reactivity coefficients with the neutron flux and the neutron flux squared. Calculations were carried out for the Zion Unit 2 PWR. Reactivity coefficients, forward fluxes and adjoint fluxes were all computed and correlations obtained. The core length was divided into 7 axial regions in order to obtain the effect on reactivity in the reactor as a whole of changing the cross sections in each axial region in turn. The parameters chosen for change were coolant density, coolant temperature and fuel temperature. The results appear to bear out our original hypothesis that the reactivity coefficient profiles have a higher positive correlation with the total flux squared profile than with the linear flux profile. (authors). 5 refs., 2 figs

  7. Advanced Neutron Spectrometer

    Science.gov (United States)

    Christl, Mark; Dobson, Chris; Norwood, Joseph; Kayatin, Matthew; Apple, Jeff; Gibson, Brian; Dietz, Kurt; Benson, Carl; Smith, Dennis; Howard, David; Rodriquez, Miguel; Watts, John; Sabra, Mohammed; Kuznetsov, Evgeny

    2013-01-01

    Energetic neutron measurements remain a challenge for space science investigations and radiation monitoring for human exploration beyond LEO. We are investigating a new composite scintillator design that uses Li6 glass scintillator embedded in a PVT block. A comparison between Li6 and Boron 10 loaded scintillators are being studied to assess the advantages and shortcomings of these two techniques. We present the details of the new Li6 design and results from the comparison of the B10 and Li6 techniques during exposures in a mixed radiation field produced by high energy protons interacting in a target material.

  8. HTS axial flux induction motor with analytic and FEA modeling

    Science.gov (United States)

    Li, S.; Fan, Y.; Fang, J.; Qin, W.; Lv, G.; Li, J. H.

    2013-11-01

    This paper presents a high-temperature superconductor (HTS) axial-flux induction motor, which can output levitation force and torque simultaneously. In order to analyze the character of the force, analytic method and finite element method are adopted to model the motor. To make sure the HTS can carry sufficiently large current and work well, the magnetic field distribution in HTS coil is calculated. An effective method to improve the critical current of HTS coil is presented. Then, AC losses in HTS windings in the motor are estimated and tested.

  9. Exploration of hemolytic model of axial blood pump

    OpenAIRE

    Miao Song; Yu Chang; Yanjiao Xuan

    2012-01-01

    Axial flow blood pumps provides additional energy to blood for heart failure patient, but its implanting destroy environment of blood cells, the direct consequence is hemolysis. According to energy conservation theorem, the severity of pump hemolysis depends on the energy utilization ratio of it. This is a new train of thought in this field. In the light of it, it¡¯s necessary to clear up how much energy used to pump blood, so part of the rest is the energy leading to hemolysis. At present, a...

  10. Lasnex Simulations of Axial Power Diagnostic for ZR

    Science.gov (United States)

    Morris, Heidi

    2015-11-01

    The dynamics of energy loss through diagnostic and/or laser entrance holes with or without shine shields is of inertial confinement fusion experiments envisioned for the National Ignition and ZR Facilities. 2-D radiation-hydrodynamic simulations using Lasnex for power diagnostic experiments using a secondary gold hohlraum fielded at the ZR facility are discussed. The axial radiation exiting the aperture of the dynamic hohlraum is modeled as time and spectrum-dependent 1-D and 2-D sources. Hohlraum energy balance and implications for the measured power are discussed.

  11. Stability analysis of restricted non-static axial symmetry

    Energy Technology Data Exchange (ETDEWEB)

    Sharif, M.; Bhatti, M. Zaeem Ul Haq, E-mail: msharif.math@pu.edu.pk, E-mail: mzaeem.math@gmail.com [Department of Mathematics, University of the Punjab, Quaid-e-Azam Campus, Lahore-54590 (Pakistan)

    2013-11-01

    This paper aims to investigate the instability of very restricted class of non-static axially symmetric spacetime with anisotropic matter configuration. The perturbation scheme is established for the Einstein field equations and conservation laws. The instability range in the Newtonian and post-Newtonian regions are explored by constructing the collapse equation in this scenario. It is found that the adiabatic index plays an important role in the stability analysis which depends upon the physical parameters i.e., energy density and anisotropic pressure of the fluid distribution.

  12. Stability analysis of restricted non-static axial symmetry

    International Nuclear Information System (INIS)

    This paper aims to investigate the instability of very restricted class of non-static axially symmetric spacetime with anisotropic matter configuration. The perturbation scheme is established for the Einstein field equations and conservation laws. The instability range in the Newtonian and post-Newtonian regions are explored by constructing the collapse equation in this scenario. It is found that the adiabatic index plays an important role in the stability analysis which depends upon the physical parameters i.e., energy density and anisotropic pressure of the fluid distribution

  13. The Bruny Island Radio Spectrometer

    Science.gov (United States)

    Erickson, W. C.

    1997-11-01

    A radio spectrometer has been built on Bruny Island, south of Hobart, for the study of solar bursts in the rarely observed frequency range from 3 to 20 MHz. This spectrometer is an adaptive device that employs digital techniques to avoid most of the strong terrestrial interference prevalent in this frequency range. The residual interference that cannot be avoided is excised during off-line processing. As a result, successful observations are made down to the minimum frequency that can propagate through the ionosphere to the antenna. This minimum frequency depends upon the zenith distance of the Sun and it is usually between 4 and 8 MHz.

  14. Comb-locked Lamb-dip spectrometer

    Science.gov (United States)

    Gatti, Davide; Gotti, Riccardo; Gambetta, Alessio; Belmonte, Michele; Galzerano, Gianluca; Laporta, Paolo; Marangoni, Marco

    2016-06-01

    Overcoming the Doppler broadening limit is a cornerstone of precision spectroscopy. Nevertheless, the achievement of a Doppler-free regime is severely hampered by the need of high field intensities to saturate absorption transitions and of a high signal-to-noise ratio to detect tiny Lamb-dip features. Here we present a novel comb-assisted spectrometer ensuring over a broad range from 1.5 to 1.63 μm intra-cavity field enhancement up to 1.5 kW/cm2, which is suitable for saturation of transitions with extremely weak electric dipole moments. Referencing to an optical frequency comb allows the spectrometer to operate with kHz-level frequency accuracy, while an extremely tight locking of the probe laser to the enhancement cavity enables a 10‑11 cm‑1 absorption sensitivity to be reached over 200 s in a purely dc direct-detection-mode at the cavity output. The particularly simple and robust detection and operating scheme, together with the wide tunability available, makes the system suitable to explore thousands of lines of several molecules never observed so far in a Doppler-free regime. As a demonstration, Lamb-dip spectroscopy is performed on the P(15) line of the 01120-00000 band of acetylene, featuring a line-strength below 10‑23 cm/mol and an Einstein coefficient of 5 mHz, among the weakest ever observed.

  15. Imaging spectrometer - An advanced multispectral imaging concept

    Science.gov (United States)

    Wellman, J. B.; Breckinridge, J. B.; Kupferman, P. N.; Salazar, R.

    1982-01-01

    The concept of an imaging spectrometer, which is being studied as a potential Space Shuttle experiment, is evaluated as a 'push-broom' imager that includes a spectrometer to disperse each line of imaging information into its spectral components. Using this instrument, the dispersed energy falls upon a two-dimensional focal plane array that detects both spatial and spectral information. As the line field of view is advanced over the earth by the motion of the spacecraft, the focal plane is read out constantly, which produces 'push-broom' images at multiple wavelengths. Ground instantaneous fields of view of 10 m in the visual and 20 m in the infrared are provided by the system, at a spectral resolution of 20 nm over the range from 0.4-2.5 microns. The system utilizes a triple-pass Schmidt optical system with a mosaic focal plane. A subset of the data stream is selected and encoded for transmission by the use of onboard processing.

  16. Selection rules and ratios for axial couplings

    CERN Document Server

    Buccella, F; Pugliese, A; Sorace, E

    1972-01-01

    The predictions for the axial couplings following from the use of the mixing operator U(Z), previously introduced to tilt the axial charges of SU/sub 6/ in the physical ones, are studied. The quantum number (-1)/sup L+L3/, where L and L/sub 3/ are the O/sub 3/ angular momentum and its third component, is shown to be conserved. From the properties of Z further predictions can be achieved as the D/F= /sup 3///sub 2/ for the /sup 1///sub 2//sup +/ baryon octet in general agreement with experiment. (14 refs).

  17. Axial Stiffness of Multiwalled Carbon Nanotubes

    OpenAIRE

    Zavalniuk, Vladimir

    2011-01-01

    The axial stiffness of MWCNTs is demonstrated to be determined only by several external shells (usually 3-5 and up to 15 for the extremely large nanotubes and high elongations) what is in a good agreement with experimentally observed inverse relation between the radius and Young modulus (i.e., stiffness) of MWCNTs. This result is a consequence of the van der Waals intershell interaction. The interpolating formula is obtained for the actual axial stiffness of MWCNT as a function of the tube ex...

  18. Axial Vircator for Electronic Warfare Applications

    Directory of Open Access Journals (Sweden)

    L. Drazan

    2009-12-01

    Full Text Available This paper deals with a high power microwave generator with virtual cathode – vircator in axial release for electronic warfare applications. The classification of directed energy weapons microwave (DEWM is introduced together with basic block diagrams of a particular class of DEWM. In the paper, methods for designing vircator pulsed power supply, axial vircator structure, measurement methods and experimental results are presented. The vircator in electromagnetic ammunition is powered by magneto-cumulative generator and in weapons for defense of objects (WDO, it is powered by Marx generator. The possible applications of a vircator in the DEWM area are discussed.

  19. A Geant4 simulation package for the SAGE spectrometer

    International Nuclear Information System (INIS)

    A comprehensive Geant4 simulation was built for the SAGE spectrometer. The simulation package includes the silicon and germanium detectors, the mechanical structure and the electromagnetic fields present in SAGE. This simulation can be used for making predictions through simulating experiments and for comparing simulated and experimental data to better understand the underlying physics.

  20. The magnetic shielding for the neutron decay spectrometer aSPECT

    OpenAIRE

    Konrad, Gertrud; Guardia, Fidel Ayala; Baeßler, Stefan(Physics Department, University of Virginia, 382 McCormick Road, Charlottesville, VA 22904, USA); Borg, Michael; Glück, Ferenc; Heil, Werner; Hiebel, Stefan; Horta, Raquel Munoz; Sobolev, Yury

    2014-01-01

    Many experiments in nuclear and neutron physics are confronted with the problem that they use a superconducting magnetic spectrometer which potentially affects other experiments by their stray magnetic field. The retardation spectrometer aSPECT consists, inter alia, of a superconducting magnet system that produces a strong longitudinal magnetic field of up to 6.2T. In order not to disturb other experiments in the vicinity of aSPECT, we had to develop a magnetic field return yoke for the magne...