WorldWideScience

Sample records for automatic gamma monitoring

  1. Requirements to a Norwegian national automatic gamma monitoring system

    DEFF Research Database (Denmark)

    Lauritzen, B.; Jensen, Per Hedemann; Nielsen, F.

    2005-01-01

    increments above the natural background levels. The study is based upon simplified deterministic calculations of the radiological consequences of generic nuclear accident scenarios. The density of gammamonitoring stations has been estimated from an analysis of the dispersion of radioactive materials over......An assessment of the overall requirements to a Norwegian gamma-monitoring network is undertaken with special emphasis on the geographical distribution of automatic gamma monitoring stations, type of detectors in such stations and the sensitivity of thesystem in terms of ambient dose equivalent rate...

  2. Requirements to a Norwegian National Automatic Gamma Monitoring System

    International Nuclear Information System (INIS)

    Lauritzen, B.; Hedemann Jensen, P.; Nielsen, F.

    2005-04-01

    An assessment of the overall requirements to a Norwegian gamma-monitoring network is undertaken with special emphasis on the geographical distribution of automatic gamma monitoring stations, type of detectors in such stations and the sensitivity of the system in terms of ambient dose equivalent rate increments above the natural background levels. The study is based upon simplified deterministic calculations of the radiological consequences of generic nuclear accident scenarios. The density of gamma monitoring stations has been estimated from an analysis of the dispersion of radioactive materials over large distances using historical weather data; the minimum density is estimated from the requirement that a radioactive plume may not slip unnoticed in between stations of the monitoring network. The sensitivity of the gamma monitoring system is obtained from the condition that events that may require protective intervention measures should be detected by the system. Action levels for possible introduction of sheltering and precautionary foodstuff restrictions are derived in terms of ambient dose equivalent rate. For emergency situations where particulates contribute with only a small fraction of the total ambient dose equivalent rate from the plume, it is concluded that measurements of dose rate are sufficient to determine the need for sheltering; simple dose rate measurements however, are inadequate to determine the need for foodstuff restrictions and spectral measurements are required. (au)

  3. Development of automatic gamma and neutron monitoring system for PFBR fuel subassemblies at IFSB

    International Nuclear Information System (INIS)

    Krishnakumar, D.N.; Dhanasekaran, A.; Ajoy, K.C.; Jose, M.T.; Baskaran, R.; Sureshkumar, K.V.

    2018-01-01

    Health physics surveillance during PFBR fuel pin assembling operation at Interim Fuel Storage Building (IFSB) mandates scanning of the fuel assembly using Telector and Rem counter to find out the maximum gamma and neutron dose rates respectively. Throughout the process health physicist involved in the operation must hold the survey meter at a constant distance from the subassembly and simultaneously should make a note of dose rate values displayed. This practice might lead to the occupational exposures and also might induce human errors during measurements. To make this process more simple, faultless and effortless, an automatic Gamma Neutron Monitoring System (AGNMS) is designed and developed at RSD to measure, store and visualize instantaneous gamma and neutron dose rates of PFBR fuel subassembly. Development of the system, calibration and deployment of the system at IFSB and preliminary results obtained using the system is depicted in this paper

  4. Automatic gamma spectrometry analytical apparatus

    International Nuclear Information System (INIS)

    Lamargot, J.-P.; Wanin, Maurice.

    1980-01-01

    This invention falls within the area of quantitative or semi-quantitative analysis by gamma spectrometry and particularly refers to a device for bringing the samples into the counting position. The purpose of this invention is precisely to provide an automatic apparatus specifically adapted to the analysis of hard gamma radiations. To this effect, the invention relates to a gamma spectrometry analytical device comprising a lead containment, a detector of which the sensitive part is located inside the containment and additionally comprising a transfer system for bringing the analyzed samples in succession to a counting position inside the containment above the detector. A feed compartment enables the samples to be brought in turn one by one on to the transfer system through a duct connecting the compartment to the transfer system. Sequential systems for the coordinated forward feed of the samples in the compartment and the transfer system complete this device [fr

  5. Automatic personnel contamination monitor

    International Nuclear Information System (INIS)

    Lattin, Kenneth R.

    1978-01-01

    United Nuclear Industries, Inc. (UNI) has developed an automatic personnel contamination monitor (APCM), which uniquely combines the design features of both portal and hand and shoe monitors. In addition, this prototype system also has a number of new features, including: micro computer control and readout, nineteen large area gas flow detectors, real-time background compensation, self-checking for system failures, and card reader identification and control. UNI's experience in operating the Hanford N Reactor, located in Richland, Washington, has shown the necessity of automatically monitoring plant personnel for contamination after they have passed through the procedurally controlled radiation zones. This final check ensures that each radiation zone worker has been properly checked before leaving company controlled boundaries. Investigation of the commercially available portal and hand and shoe monitors indicated that they did not have the sensitivity or sophistication required for UNI's application, therefore, a development program was initiated, resulting in the subject monitor. Field testing shows good sensitivity to personnel contamination with the majority of alarms showing contaminants on clothing, face and head areas. In general, the APCM has sensitivity comparable to portal survey instrumentation. The inherit stand-in, walk-on feature of the APCM not only makes it easy to use, but makes it difficult to bypass. (author)

  6. Automatic calibration of gamma spectrometers

    International Nuclear Information System (INIS)

    Tluchor, D.; Jiranek, V.

    1989-01-01

    The principle is described of energy calibration of the spectrometric path based on the measurement of the standard of one radionuclide or a set of them. The entire computer-aided process is divided into three main steps, viz.: the insertion of the calibration standard by the operator; the start of the calibration program; energy calibration by the computer. The program was selected such that the spectrum identification should not depend on adjustment of the digital or analog elements of the gamma spectrometric measuring path. The ECL program is described for automatic energy calibration as is its control, the organization of data file ECL.DAT and the necessary hardware support. The computer-multichannel analyzer communication was provided using an interface pair of Canberra 8673V and Canberra 8573 operating in the RS-422 standard. All subroutines for communication with the multichannel analyzer were written in MACRO 11 while the main program and the other subroutines were written in FORTRAN-77. (E.J.). 1 tab., 4 refs

  7. Characterization of a gamma spectrometry monitor LaBr{sub 3} automatic stations for environmental monitoring; Caracterizacion de un monitor de espectrometria gamma de LaBr{sub 3} para las estaciones automaticas de vigilancia ambiental

    Energy Technology Data Exchange (ETDEWEB)

    Vargas, A.; Salvador-Castineria, P.; Roig, M.; Fernandez-Varea, J. M.; Padro, A.

    2011-07-01

    The Institut de Techniques Energetiques (INTE) of the Universitat Politecnica de Catalunya (UPC) is collaborating with the German Radiation Protection (BfS) in order to characterize LaBr{sub 3} detector developed by the BfS for future installation of monitoring networks automatic. This paper presents the results obtained with the monitor installed on the roof of the premises of INTE South Campus located in Barcelona and Monte Carlo simulations that complement its characterization.

  8. Calibration and study of the measurement capabilities of real-time gamma spectrometry equipment developed for the renewal of the network of stations automatic monitoring environmental radiation of the Generalitat of Catalunya

    International Nuclear Information System (INIS)

    Casanovas, R.; Prieto, E.; Salvado, M.

    2014-01-01

    The renewal of the automatic environmental radiation surveillance network of the Generalitat of Catalunya has been carried out through the development and implementation of gamma-spectrometry-based equipment. the monitors use scintillation crystals, either Na(TI) or LaBr 3 (Ce) and currently, there are 3 types of equipment water radioactivity monitors, aerosols on a particulate filter monitors and direct measurement monitors. In this paper, we expose the basic features of its operation, the details of their calibration and the minimum detectable activity concentration for some isotopes. (Author)

  9. An automatic sample changer for gamma spectrometry

    International Nuclear Information System (INIS)

    Andrews, D.J.

    1984-01-01

    An automatic sample changer for gamma spectrometry is described which is designed for large-volume, low radioactivity environmental samples of various sizes up to maximum dimensions 100 mm diameter x 60 mm high. The sample changer is suitable for use with most existing gamma spectrometry systems which utilize GeLi or NaI detectors in vertical mode, in conjunction with a pulse height analyzer having auto-cycle and suitable data output facilities; it is linked to a Nuclear Data ND 6620 computer-based analysis system. (U.K.)

  10. Automatic radioxenon analyzer for CTBT monitoring

    International Nuclear Information System (INIS)

    Bowyer, T.W.; Abel, K.H.; Hensley, W.K.

    1996-12-01

    Over the past 3 years, with support from US DOE's NN-20 Comprehensive Test Ban Treaty (CTBT) R ampersand D program, PNNL has developed and demonstrated a fully automatic analyzer for collecting and measuring the four Xe radionuclides, 131m Xe(11.9 d), 133m Xe(2.19 d), 133 Xe (5.24 d), and 135 Xe(9.10 h), in the atmosphere. These radionuclides are important signatures in monitoring for compliance to a CTBT. Activity ratios permit discriminating radioxenon from nuclear detonation and that from nuclear reactor operations, nuclear fuel reprocessing, or medical isotope production and usage. In the analyzer, Xe is continuously and automatically separated from the atmosphere at flow rates of about 7 m 3 /h on sorption bed. Aliquots collected for 6-12 h are automatically analyzed by electron-photon coincidence spectrometry to produce sensitivities in the range of 20-100 μBq/m 3 of air, about 100-fold better than with reported laboratory-based procedures for short time collection intervals. Spectral data are automatically analyzed and the calculated radioxenon concentrations and raw gamma- ray spectra automatically transmitted to data centers

  11. Automatically processed alpha-track radon monitor

    International Nuclear Information System (INIS)

    Langner, G.H. Jr.

    1993-01-01

    An automatically processed alpha-track radon monitor is provided which includes a housing having an aperture allowing radon entry, and a filter that excludes the entry of radon daughters into the housing. A flexible track registration material is located within the housing that records alpha-particle emissions from the decay of radon and radon daughters inside the housing. The flexible track registration material is capable of being spliced such that the registration material from a plurality of monitors can be spliced into a single strip to facilitate automatic processing of the registration material from the plurality of monitors. A process for the automatic counting of radon registered by a radon monitor is also provided

  12. Automatic mapping of monitoring data

    DEFF Research Database (Denmark)

    Lophaven, Søren; Nielsen, Hans Bruun; Søndergaard, Jacob

    2005-01-01

    of identifying a release of radioactivity provided that the number of sampling locations is sufficiently high. Consequently, we believe that a combination of applying the presented mapping approach and the physical knowledge of the transport processes of radioactivity should be used to predict the extreme values.......). In the second dataset an accidental release of radioactivity in the environment was simulated in the South-Western corner of the monitored area. The approach has a tendency to smooth the actual data values, and therefore it underestimates extreme values, as seen in the second dataset. However, it is capable...

  13. Calibration and study of the measurement capabilities of real-time gamma spectrometry equipment developed for the renewal of the network of stations automatic monitoring environmental radiation of the Generalitat of Catalunya; Calibracion y estudio de las capacidades de medida de los equipos de espectrometria gamma en tiempo real desarrollados para la renovacion de la Red de Estaciones Automaticas de vigilancia radiologia ambiental de la Generalitat de Catalunya

    Energy Technology Data Exchange (ETDEWEB)

    Casanovas, R.; Prieto, E.; Salvado, M.

    2014-10-01

    The renewal of the automatic environmental radiation surveillance network of the Generalitat of Catalunya has been carried out through the development and implementation of gamma-spectrometry-based equipment. the monitors use scintillation crystals, either Na(TI) or LaBr{sub 3}(Ce) and currently, there are 3 types of equipment water radioactivity monitors, aerosols on a particulate filter monitors and direct measurement monitors. In this paper, we expose the basic features of its operation, the details of their calibration and the minimum detectable activity concentration for some isotopes. (Author)

  14. Development of air equivalent gamma dose monitor

    International Nuclear Information System (INIS)

    Alex, Mary; Bhattacharya, Sadhana; Karpagam, R.; Prasad, D.N.; Jakati, R.K.; Mukhopadhyay, P.K.; Patil, R.K.

    2010-01-01

    The paper describes design and development of air equivalent gamma absorbed dose monitor. The monitor has gamma sensitivity of 84 pA/R/h for 60 Co source. The characterization of the monitor has been done to get energy dependence on gamma sensitivity and response to gamma radiation field from 1 R/hr to 5000 R/hr. The gamma sensitivity in the energy range of 0.06 to 1.25MeV relative to 137 Cs nuclide was within 2.5%. The linearity of the monitor response as a function of gamma field from 10 R/h to 3.8 kR/h was within 6%. The monitor has been designed for its application in harsh environment. It has been successfully qualified to meet environmental requirements of shock. (author)

  15. A computer program for automatic gamma-ray spectra analysis

    International Nuclear Information System (INIS)

    Hiromura, Kazuyuki

    1975-01-01

    A computer program for automatic analysis of gamma-ray spectra obtained with a Ge(Li) detector is presented. The program includes a method by comparing the successive values of experimental data for the automatic peak finding and method of leastsquares for the peak fitting. The peak shape in the fitting routine is a 'modified Gaussian', which consists of two different Gaussians with the same height joined at the centroid. A quadratic form is chosen as a function representing the background. A maximum of four peaks can be treated in the fitting routine by the program. Some improvements in question are described. (auth.)

  16. [Development of automatic urine monitoring system].

    Science.gov (United States)

    Wei, Liang; Li, Yongqin; Chen, Bihua

    2014-03-01

    An automatic urine monitoring system is presented to replace manual operation. The system is composed of the flow sensor, MSP430f149 single chip microcomputer, human-computer interaction module, LCD module, clock module and memory module. The signal of urine volume is captured when the urine flows through the flow sensor and then displayed on the LCD after data processing. The experiment results suggest that the design of the monitor provides a high stability, accurate measurement and good real-time, and meets the demand of the clinical application.

  17. A wide range gamma monitor with digital display for remote monitoring

    International Nuclear Information System (INIS)

    Risbud, V.H.; Thiagarajan, A.; Gangadharan, P.

    1976-01-01

    A wide range gamma monitor designed for remote monitoring in nuclear facilities is described. The instrument consists of two GM detectors and pre-amplifiers connected by a long coaxial cable to the power supply, scalers and timers and display devices. Automatic selection of detectors range of exposure rate and display (nixie) are achieved with this set up, radiation levels in active areas can easily be displayed in the control room. Other advantages are also pointed out. (A.K.)

  18. Gamma ray spectroscopy monitoring method and apparatus

    Science.gov (United States)

    Stagg, William R; Policke, Timothy A

    2017-05-16

    The present invention relates generally to the field of gamma ray spectroscopy monitoring and a system for accomplishing same to monitor one or more aspects of various isotope production processes. In one embodiment, the present invention relates to a monitoring system, and method of utilizing same, for monitoring one or more aspects of an isotope production process where the monitoring system comprises: (A) at least one sample cell; (B) at least one measuring port; (C) at least one adjustable collimator device; (D) at least one shutter; and (E) at least one high resolution gamma ray spectrometer.

  19. Development of Automatic Remote Exposure Controller for Gamma Radiography

    International Nuclear Information System (INIS)

    Joo, Gwang Tae; Shin, Jin Seong; Kim, Dong Eun; Song, Jung Ho; Choo, Seung Hwan; Chang, Hong Keun

    2002-01-01

    Recently, gamma radiographic equipment have been used about 1,000 sets manually and operated by about 2,500 persons in Korea. In order for a radiography to work effectively with avoiding any hazard of the high level radiation from the source, many field workers have expected developing a wireless automatic remote exposure controller. The KlTCO research team has developed an automatic remote exposure controller that can regulate the speed of 0.4∼1.2m/s by BLDC motor of 24V 200W which has output of 54 kgf·, suitable torque and safety factor for the work. And the developed automatic remote exposure controller can control rpm of motor, pigtail position by photo-sensor and exposure time by timer to RF sensor. Thus, the developed equipment is expected that the unit can be used in many practical applications with benefits in economical advantage to combine the use of both automatic and manual type because attachment is possible existent manual remote exposure controller, AC and DC combined use

  20. Monitoring of low level environmental gamma exposure by the centralized radiation monitoring system

    International Nuclear Information System (INIS)

    Katagiri, Hiroshi; Kobayashi, Hideo; Obata, Kazuichi; Kokubu, Morinobu; Itoh, Naoji

    1981-07-01

    In the Japan Atomic Energy Research Institute (JAERI), a centralized automatic radiation monitoring system developed 20 years ago has recently been improved to monitor low level gamma radiation more accurately in normal operation of the nuclear facilities and to detect abnormal radioactive releases more effectively. The present state of the system is described. This system puts together environmental monitoring data such as gamma exposure rate (20 points), radioactive concentration in the air (4 points) and in water (2 drains), and meteorological items (14 including wind directions, wind speeds, solar radiation and air temperatures at a observation tower of 40 m height). Environmental monitoring around the JAERI site is carried out effectively using the system. Data processing system consists of a central processing unit, a magnetic disk, a magnetic tape, a line printer and a console typewriter. The data at respective monitoring points are transmitted to the central monitoring room by wireless or telephone line. All data are printed out and field in magnetic disk and magnetic tape every 10 minutes. When the emergency levels are exceeded, however, the data are automatically output on a line printer every 2 minute. This system can distinguish very low gamma exposure due to gaseous effluents, about 1 mR/y, from the background. Even in monthly exposures, calculated values based on the data of release amount and meteorology are in good agreement with the measured ones. (author)

  1. Gamma ampersand beta-gamma storm water monitor operability

    International Nuclear Information System (INIS)

    Tshiskiku, E.M.

    1993-01-01

    High Level Waste (HLW) facilities have nine storm water monitors that monitor storm water run off from different process areas for Cesium 137, a Gamma emitter. F - Area has three monitors: 907-2F, 907-3F and 907-4F while H - Area has six monitors: 907-2H, 907-3H, 907-4H, 907-5H, 907-6H and 907-7H (See attachments number-sign 1, number-sign 2 and number-sign 3 for location). In addition to monitoring for Cesium, 907-6H and 907-7H monitor for Strontium-90, a Beta emitter. Each monitor is associated with one of the following diversion gate encasements 907-1H, 241-15H, 241-51H, 907-1F or 241-23F. Normal flow of storm water from these diversion gate encasements is to the Four Mile Creek. When a storm water monitor detects radioactivity at a level exceeding the Four Mile Creek discharge limit, the monitor causes repositioning of the associated diversion gate to discharge to the H - Area retention basin 281-8H or the F - Area retention basin 281-8F. In response to recent OSR interpretation of storm water monitor calibration requirements, this report is provided to document operability and accuracy of radiation detection

  2. Automatic analysis algorithm for radionuclide pulse-height data from beta-gamma coincidence systems

    International Nuclear Information System (INIS)

    Foltz Biegalski, K.M.

    2001-01-01

    There are two acceptable noble gas monitoring measurement modes for Comprehensive Nuclear-Test-Ban-Treaty (CTBT) verification purposes defined in CTBT/PC/II/WG.B/1. These include beta-gamma coincidence and high-resolution gamma-spectrometry. There are at present no commercial, off-the-shelf (COTS) applications for the analysis of β-γ coincidence data. Development of such software is in progress at the Prototype International Data Centre (PIDC) for eventual deployment at the International Data Centre (IDC). Flowcharts detailing the automatic analysis algorithm for β-γ coincidence data to be coded at the PIDC is included. The program is being written in C with Oracle databasing capabilities. (author)

  3. Prompt Gamma Ray Spectroscopy for process monitoring

    International Nuclear Information System (INIS)

    Zoller, W.H.; Holmes, J.L.

    1991-01-01

    Prompt Gamma Ray Spectroscopy (PGRS) is a very powerful analytical technique able to measure many metallic, contamination problem elements. The technique involves measurement of gamma rays that are emitted by nuclei upon capturing a neutron. This method is sensitive not only to the target element but also to the particular isotope of that element. PGRS is capable of measuring dissolved metal ions in a flowing system. In the field, isotopic neutron sources are used to produce the desired neutron flux ( 252 Cf can produce neutron flux of the order of 10 8 neutrons/cm 2 --sec.). Due to high penetrating power of gamma radiation, high efficiency gamma ray detectors can be placed in an appropriate geometry to maximize sensitivity, providing real-time monitoring with low detection level capabilities

  4. Programmer for automatic gamma spectrometry; Ordonnateur de sequence pour spectrometrie gamma automatique

    Energy Technology Data Exchange (ETDEWEB)

    Romanetti, R [Commissariat a l' Energie Atomique, Cadarache (France). Centre d' Etudes Nucleaires

    1968-04-01

    With this apparatus, which is constructed of logical integrated circuits, it is possible both to synchronize an automatic gamma spectrometry assembly and to record the spectra on punched cards. An IBM terminal will make it possible with the help of analysis by the least squares method and by a direct dialogue with an IBM 360 computer to obtain analytical results almost instantaneously. (author) [French] Cet appareil, realise en circuits integres logiques, permet d'une part de synchroniser un ensemble automatique de spectrometrie gamma et d'autre part d'enregistrer les spectres sur cartes perforees. Un terminal IBM permettra, a l'aide d'un programme d'analyse par la methode des moindres carres et par un dialogue direct avec un ordinateur IBM 360, de disposer presque intanstanement des resultats des analyses. (auteur)

  5. Automatic analysis of gamma spectra using a desk computer

    International Nuclear Information System (INIS)

    Rocca, H.C.

    1976-10-01

    A code for the analysis of gamma spectra obtained with a Ge(Li) detector was developed for use with a desk computer (Hewlett-Packard Model 9810 A). The process is performed in a totally automatic way, data are conveniently smoothed and the background is generated by a convolutive equation. A calibration of the equipment with well-known standard sources gives the necessary data for adjusting a third degree equation by minimun squares, relating the energy with the peak position. Criteria are given for determining if certain groups of values constitute or not a peak or if it is a double line. All the peaks are adjusted to a gaussian curve and if necessary decomposed in their components. Data entry is by punched tape, ASCII Code. An alf-numeric printer provides (a) the position of the peak and its energy, (b) its resolution if it is larger than expected, (c) the area of the peak with its statistic error determined by the method of Wasson. As option, the complete spectra with the determined background can be plotted. (author) [es

  6. Unattented mode monitoring of high resolution gamma-ray spectra

    International Nuclear Information System (INIS)

    Smith, B.G.R.; Van Dyck, P.; Debraix, P.

    1991-01-01

    An Isotope Monitoring System (IMS) for unattended spectrum acquisition is described. This consists of a simple low cost flexible software package running on a Compaq 80386 and controlling up to 4 Canberra Packard System 100 multi-channel analyzer (MCA) cards. The IMS permits the independent configuration of each of the 4 MCA cards for different monitoring cycles and for different spectrum acquisition cycles each being based upon different trigger criteria. In this way IMS is able to automatically identify events, time tag them, and acquire and store valid spectra corresponding to those event. An additional feature of IMS permits to run a Multigroup Analysis (MGA) software package for the determination of plutonium isotopic compositions in batch mode. One particular application is discussed which consists of 4 high resolution gamma-ray detector systems connected together to the IMS for unattended spectrum acquisition. The off-line batch mode analysis of the spectra using MGA is also discussed

  7. System for continuous real time air monitoring by means of gamma spectrometry with germanium dosimeter

    International Nuclear Information System (INIS)

    Montalto, M.; Giacomelli, R.; Nocente, M.; Bortoluzzi, S.; Spezzano, P.

    1990-12-01

    Design of automatic system for real time air monitoring of radioactive particulates are relate. Recommendations are made for design and operation of sampling conduits to minimize losses. By means of experimental equipment loss of particles in long sampling conduits, minimum detectable activity and efficiency of gamma radiation detectable are evaluated. (author)

  8. Automated TLD system for gamma radiation monitoring

    International Nuclear Information System (INIS)

    Nyberg, P.C.; Ott, J.D.; Edmonds, C.M.; Hopper, J.L.

    1979-01-01

    A gamma radiation monitoring system utilizing a commercially available TLD reader and unique microcomputer control has been built to assess the external radiation exposure to the resident population near a nuclear weapons testing facility. Maximum use of the microcomputer was made to increase the efficiency of data acquisition, transmission, and preparation, and to reduce operational costs. The system was tested for conformance with an applicable national standard for TLD's used in environmental measurements

  9. Unisampo/shaman/linssi Automatic gamma-spectrum pipeline for nuclear emergency preparedness

    International Nuclear Information System (INIS)

    Zhang Weihua; Kurt Ungar; Pertti Aainio; Jarmo Ala-Heikkila; Harri Toivonen; Teemu Siiskonen; Arto Isolankila; Antero Kuusi

    2005-01-01

    Linux System for Spectral Information (LINSSI) is an SQL database and established under Linux. It is being developed in collaboration with the Radiation Physics Group of Helsinki University of Technology (RPG/HUT), Finnish National Data Centre (FiNDC), Aerosol Laboratory of the Finnish Radiation and Nuclear Safety Authority (ASL/STUK) and Radiation Protection Bureau of Health Canada (RPB/HC). The database is for environmental radiation monitoring and nuclear emergency preparedness purposes. It is designed not only for storage of information but it is also a platform for interfacing different analysis tools. The structure of database has been published and described at website http://www.hut.fi/Units/AES/projects/radphys/linssi/. It is created as a transparent database structure which could be used for different applications. Thus, other companies and organization are encouraged to provide software to handle and share the information in the database, both in the form of input and output. In January 2004, first LINSSI database released at STUK is compatible with UniSampo/Shaman. Unisampo is a peak analysis software with some identification capabilities; Shaman is the genuine nuclide identification software and also for activity calculation and Linssi is a MySQL database. Now the system is mainly focus on Gamma-ray spectrometry. After a short period of testing, this automatic pipeline becomes operational at PRB in April 2004. Currently daily Gamma spectrum information from all CTBT radionuclide monitoring stations have been processing automatically; at this moment more than 20 thousand cases have been stored in database. A www-based user interface, zero time calculation, station statistic analysis tool and ARR report scripts have been developed. In recent System-wide Performance Test (SPT) of CTBT, the pipeline played an important role at Canadian nuclear data center. With this system we can very easily report the automated, also the reviewed results to IDC based on

  10. Programs for the automatic gamma-ray measurement with CANBERRA 8100/QUANTA system

    International Nuclear Information System (INIS)

    Yoshida, Hiroshi; Sakai, Eiji; Kubo, Katsumi.

    1982-07-01

    Some programs have been prepared for the automatic operation of the CANBERRA 8100/QUANTA System for the gamma-ray spectrum measurement. The main parts of these programs are: (1) to collect and record on magnetic disks the data of gamma-ray spectra automatically, while the recorded data are analyzed to estimate the nuclides which generate photopeaks of spectra and to calculate those concentrations; (2) to draw plotted diagrams of pulse height distributions of gamma-ray spectra data and other data by the additional digital plotter; and etc. (author)

  11. New automatic radiation monitoring network in Slovenia

    International Nuclear Information System (INIS)

    Cindro, M.; Vokal Nemec, B.

    2006-01-01

    The Slovenian Nuclear Safety Administration gathers all on-line dose rate data measured by the various automatic networks operating throughout the territory of Slovenia. With the help of the PHARE financing program and in close cooperation with the Environmental agency of RS the upgrade of the existing network begun in 2005 and was finished in March 2006. The upgrade provided new measuring sites with all relevant data needed in case of a radiological accident. Even bigger improvement was made in the area of data presentation and analysis, which was the main shortcoming of the old system. (author)

  12. An Automatic and Real-time Restoration of Gamma Dose Data by Radio Telemetry

    International Nuclear Information System (INIS)

    Lee, Wan No; Kim, Hee Reyoung; Chung, Kun Ho; Cho, Young Hyun; Choi, Geun Sik; Lee, Chang Woo; Kim, Young Soo

    2006-01-01

    On-line gamma monitoring system based on a high pressurized ionization chamber has been used for determining airborne doses surrounding HANARO research reactor at KAERI (Korea Atomic Energy Research Institute). It is composed of a network of six monitoring stations and an on-line computer system. It has been operated by radio telemetry with a radio frequency of 468.8 MHz, which is able to transmit the real-time dose data measured from a remote ion chamber to the central computer for ten seconds-to seconds. Although radio telemetry has several advantages such as an effective and economical transmission, there is one main problem that data loss happen because each monitoring post only stores 300 radiation data points, which covers the previous sequential data of 50 minutes from the present in the case of a recording interval time of 10 seconds It is possible to restore the lost data by an off-line process such as a floppy disk or portable memory disk but it is ineffective method at the real-time monitoring system. Restoration, storage, and display of the current data as well as the lost data are also difficult in the present system. In this paper, an automatic and real-time restoration method by radio telemetry will be introduced

  13. Exporting automatic vehicle SNM monitoring technology

    International Nuclear Information System (INIS)

    York, R.L.; Fehlau, P.E.; Close, D.A.

    1995-01-01

    Controlling the transportation of nuclear materials is still one of the most effective nuclear proliferation barriers. The recent increase of global nuclear material proliferation has expanded the application of vehicle monitor technology to prevent the diversion of special nuclear material across international borders. To satisfy this new application, a high-sensitivity vehicle monitor, which is easy to install and capable of operating in high-traffic areas, is required. A study of a new detector configuration for a drive-through vehicle monitor is discussed in this paper

  14. Automatic acoustic and vibration monitoring system for nuclear power plants

    International Nuclear Information System (INIS)

    Tothmatyas, Istvan; Illenyi, Andras; Kiss, Jozsef; Komaromi, Tibor; Nagy, Istvan; Olchvary, Geza

    1990-01-01

    A diagnostic system for nuclear power plant monitoring is described. Acoustic and vibration diagnostics can be applied to monitor various reactor components and auxiliary equipment including primary circuit machinery, leak detection, integrity of reactor vessel, loose parts monitoring. A noise diagnostic system has been developed for the Paks Nuclear Power Plant, to supervise the vibration state of primary circuit machinery. An automatic data acquisition and processing system is described for digitalizing and analysing diagnostic signals. (R.P.) 3 figs

  15. Automatic duress alarms through physiological response monitoring

    International Nuclear Information System (INIS)

    Roehrig, S.C.

    1977-07-01

    Physiological response monitoring under controlled conditions can provide an effective means for passively determining if the wearer is under moderate to severe stresses. By monitoring the heart rate (HR) and galvanic skin response (GSR) of an individual, it is possible to detect in real time the increase in heart rate and GSR levels due to physiological reactions to mental duress. With existing physiological monitoring equipment, however, the work load of the wearer must be well defined since it is impossible, without additional data, to distinguish mental duress responses from those resulting from moderate physical exertion. Similarly, environmental conditions should be constrained within set limits to avoid masking increases in GSR levels due to metntal stress from those associated with increased perspiration. These constraints should not prove overly restrictive and would allow an integrated security system utilizing physiological monitoring equipment to provide an effective real time, automated early warning system for detection of mental duress or death of the wearer

  16. Development of an automatic prompt gamma-ray activation analysis system

    International Nuclear Information System (INIS)

    Osawa, Takahito

    2013-01-01

    An automatic prompt gamma-ray activation analysis system was developed and installed at the Japan Research Reactor No. 3 Modified (JRR-3M). The main control software, referred to as AutoPGA, was developed using LabVIEW 2011 and the hand-made program can control all functions of the analytical system. The core of the new system is an automatic sample exchanger and measurement system with several additional automatic control functions integrated into the system. Up to fourteen samples can be automatically measured by the system. (author)

  17. Automatic Flushing Unit With Cleanliness Monitor

    Science.gov (United States)

    Hildebrandt, N. E.

    1982-01-01

    Liquid-level probe kept clean, therefore at peak accuracy, by unit that flushes probe with solvent, monitors effluent for contamination, and determines probe is particle-free. Approach may be adaptable to industrial cleaning such as flushing filters and pipes, and ensuring that manufactured parts have been adequately cleaned.

  18. Real time monitoring automation of dose rate absorbed in air due to environmental gamma radiation

    International Nuclear Information System (INIS)

    Dominguez Ley, Orlando; Capote Ferrera, Eduardo; Carrazana Gonzalez, Jorge A.; Manzano de Armas, Jose F.; Alonso Abad, Dolores; Prendes Alonso, Miguel; Tomas Zerquera, Juan; Caveda Ramos, Celia A.; Kalber, Olof; Fabelo Bonet, Orlando; Montalvan Estrada, Adelmo; Cartas Aguila, Hector; Leyva Fernandez, Julio C.

    2005-01-01

    The Center of Radiation Protection and Hygiene (CPHR) as the head institution of the National Radiological Environmental Surveillance Network (RNVRA) has strengthened its detection and response capacity for a radiological emergency situation. The measurements of gamma dose rate at the main point of the RNVRA are obtained in real time and the CPHR receives the data coming from those points in a short time. To achieve the operability of the RNVRA it was necessary to complete the existent monitoring facilities using 4 automatic gamma probes, implementing in this way a real time measurement system. The software, GenitronProbe for obtaining the data automatically from the probe, Data Mail , for sending the data via e-mail, and Gamma Red , for receiving and processing the data in the head institution ,were developed

  19. Automatic outdoor monitoring system for photovoltaic panels.

    Science.gov (United States)

    Stefancich, Marco; Simpson, Lin; Chiesa, Matteo

    2016-05-01

    Long-term acquisition of solar panel performance parameters, for panels operated at maximum power point in their real environment, is of critical importance in the photovoltaic research sector. However, few options exist for the characterization of non-standard panels such as concentrated photovoltaic systems, heavily soiled or shaded panels or those operating under non-standard spectral illumination; certainly, it is difficult to find such a measurement system that is flexible and affordable enough to be adopted by the smaller research institutes or universities. We present here an instrument aiming to fill this gap, autonomously tracking and maintaining any solar panel at maximum power point while continuously monitoring its operational parameters and dissipating the produced energy without connection to the power grid. The instrument allows periodic acquisition of current-voltage curves to verify the employed maximum power point tracking approach. At the same time, with hardware schematics and software code being provided, it provides a flexible open development environment for the monitoring of non-standard generators like concentrator photovoltaic systems and to test novel power tracking approaches. The key issues, and the corresponding solutions, encountered in the design are analyzed in detail and the relevant schematics presented.

  20. Automatic outdoor monitoring system for photovoltaic panels

    Energy Technology Data Exchange (ETDEWEB)

    Stefancich, Marco [Consiglio Nazionale delle Ricerce, Istituto dei Materiali per l’Elettronica ed il Magnetismo (CNR-IMEM), Parco Area delle Scienze 37/A, 43124 Parma, Italy; Simpson, Lin [National Renewable Energy Laboratory, 15013 Denver West Parkway, Golden, Colorado 80401, USA; Chiesa, Matteo [Masdar Institute of Science and Technology, P.O. Box 54224, Masdar City, Abu Dhabi, United Arab Emirates

    2016-05-01

    Long-term acquisition of solar panel performance parameters, for panels operated at maximum power point in their real environment, is of critical importance in the photovoltaic research sector. However, few options exist for the characterization of non-standard panels such as concentrated photovoltaic systems, heavily soiled or shaded panels or those operating under non-standard spectral illumination; certainly, it is difficult to find such a measurement system that is flexible and affordable enough to be adopted by the smaller research institutes or universities. We present here an instrument aiming to fill this gap, autonomously tracking and maintaining any solar panel at maximum power point while continuously monitoring its operational parameters and dissipating the produced energy without connection to the power grid. The instrument allows periodic acquisition of current-voltage curves to verify the employed maximum power point tracking approach. At the same time, with hardware schematics and software code being provided, it provides a flexible open development environment for the monitoring of non-standard generators like concentrator photovoltaic systems and to test novel power tracking approaches. The key issues, and the corresponding solutions, encountered in the design are analyzed in detail and the relevant schematics presented.

  1. Automatic monitoring of vibration welding equipment

    Science.gov (United States)

    Spicer, John Patrick; Chakraborty, Debejyo; Wincek, Michael Anthony; Wang, Hui; Abell, Jeffrey A; Bracey, Jennifer; Cai, Wayne W

    2014-10-14

    A vibration welding system includes vibration welding equipment having a welding horn and anvil, a host device, a check station, and a robot. The robot moves the horn and anvil via an arm to the check station. Sensors, e.g., temperature sensors, are positioned with respect to the welding equipment. Additional sensors are positioned with respect to the check station, including a pressure-sensitive array. The host device, which monitors a condition of the welding equipment, measures signals via the sensors positioned with respect to the welding equipment when the horn is actively forming a weld. The robot moves the horn and anvil to the check station, activates the check station sensors at the check station, and determines a condition of the welding equipment by processing the received signals. Acoustic, force, temperature, displacement, amplitude, and/or attitude/gyroscopic sensors may be used.

  2. Design of an automatic sample changer for the measurement of neutron flux by gamma spectrometry

    International Nuclear Information System (INIS)

    Gago, Javier; Bruna, Ruben; Baltuano, Oscar; Montoya, Eduardo; Descreaux, Killian

    2014-01-01

    This paper presents calculus, selection and components design for the construction of an automatic system in order to measure neutron flux in a working nuclear reactor by the gamma spectrometry technique using samples irradiated on the RP-10 nucleus. This system will perform the measurement of interchanging 100 samples in a programed and automatic way, reducing operation time by the user and obtaining more accurate measures. (authors).

  3. The Role of Automatic Radiation Monitoring in Control of Illicit Trafficking of Radioactive Materials in Slovenia

    International Nuclear Information System (INIS)

    Mitic, D.

    2003-01-01

    Automatic radiation monitoring in Slovenia comprises monitoring of external gamma radiation, aerosol radioactivity, radon progeny concentration, and radioactive deposition measurements. The officer on duty has an important part in assuring proper and undisturbed functioning of our automatic radiation monitoring. He is the one who gets the first alert message on radiation levels when exceeded pre-set values in the territory of Slovenia. Together with continuous control over the functioning of automatic radiation monitoring, the officer on duty has been also assigned for receiving messages from users, who carry the 'Radiation pager' (it is a trade mark for Sensor Technology Engineering, inc. from USA). All valuable experiences of the officer on duty who has been accepting reports from customs officers, police officers, from Slovenian radiation and nuclear safety inspectors, are described in this article. The officer on duty with his new role contributes to prevention of the illicit trafficking and inadvertent movement of radioactive materials over the territory of Slovenia. In the last year there where many different causes of emergency calls: from many cases of patient after radioisotopes medical treatment to serious rejected shipment with exceeded radiation. This is only a beginning of responsible task how to introduce and assure the control of the inadvertent movement of radioactive materials in Slovenia. (author)

  4. Low-cost automatic station for compost temperature monitoring

    Directory of Open Access Journals (Sweden)

    Marcelo D. L. Jordão

    Full Text Available ABSTRACT Temperature monitoring is an important procedure to control the composting process. Due to cost limitation, temperature monitoring is manual and with daily sampling resolution. The objective of this study was to develop an automatic station with US$ 150 dollars, able to monitor air temperature at two different points in a compost pile, with a 5-min time resolution. In the calibration test, the sensors showed an estimated uncertainty from ± 1 to ± 1.9 ºC. In the field validation test, the station guaranteed secure autonomy for seven days and endured high humidity and extreme temperature (> 70 °C.

  5. A new type gamma-ray spectrum monitoring system

    CERN Document Server

    Cheng Bo; Zhou Jian Bin; Zhang Zhi Ming; Tong Yun Fu

    2002-01-01

    This new radiation monitoring system can be used to monitor the radiation of building materials and the radiation of atmosphere, to explore and evaluate rock for building in the field, and this system can be used to monitor the gamma irradiation near the nuclear establishments in the average situation and in the serious situation of the radiation incident have happened. The control core of this monitoring system is SCM-AT89C52, and gamma-ray sensing head consists of scintillator phi 50 mm x 50 mm NaI(Tl) and PMT GDB44. This system can be used to measure the whole gamma-ray spectrum of 256 channels

  6. Automatic continuous monitoring system for dangerous sites and cargoes

    International Nuclear Information System (INIS)

    Smirnov, S.N.

    2009-01-01

    The problems of creation of automatic comprehensive continuous monitoring system for nuclear and radiation sites and cargoes of Rosatom Corporation, which carries out data collecting, processing, storage and transmission, including informational support to decision-making, as well as support to modelling and forecasting functions, are considered. The system includes components of two levels: site and industry. Currently the system is used to monitor over 8000 integrated parameters, which characterise the status of nuclear and radiation safety on Rosatom sites, environmental and fire safety

  7. Automatic national network of radiation environmental monitoring in Mexico

    International Nuclear Information System (INIS)

    Aguirre, Jaime; Delgado, Jose L.; Lopez, Manuel; Zertuche, Jorge V.

    2013-01-01

    The Direccion de Vigilancia Radiologica (DVR) of the Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS) de Mexico, performs several function for environmental radiation monitoring. One of these functions is the permanent monitoring of the environmental gamma radiation. For this, it implemented the Red Nacional Automatica de Monitoreo Radiologico Ambiental (RENAMORA) - the National Automated Network for Environmental Radiation Monitoring,which currently comprises 60 detector probes for gamma radiation which with a programmable system that includes information technologies, data transmission and software can send the information in real time to a primary center of data located in the facilities of CNSNS. - When the data are received, the system performs the verification and extraction of the information organized in Tables and charts, and generates a report of environmental gamma radiation dose rate average for each of the probes and for each period of time determined bu CNSNS. The RENAMORA covers the main cities and allows to establish the bases of almost the entire country, as well as to warn about abnormal situations caused by incidents or natural events generated by human activities inside or outside the country which involves radioactive materials; paying special attention to main radiological sites, such as the surroundings of the Laguna Verde Nuclear Power Plants, research centers and the radioactive waste disposal sites

  8. Technological and operational structure of the National Automatic Network for Environmental Radiological Monitoring (RENAMORA)

    International Nuclear Information System (INIS)

    Martinez G, E.; Lopez G, M.; Aguirre G, J.; Fabian O, R.; Hernandez A, Y.

    2015-09-01

    The Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS) in Mexico is a decentralized body, under the Secretaria de Energia whose main mission is to ensure that activities involving nuclear and radioactive materials as well as ionizing radiation sources are carried out with maximum security, considering the current technological developments. In order to monitor the levels of environmental radiation to which the population is exposed, the CNSNS has established a series of radiological monitoring programs that allow characterize the environmental radiation levels in each zone or region in the country; to identify the occurrence of natural or artificial radiological events, such as nuclear tests and accidents in radioactive or nuclear facilities. The National Automatic Network for Environmental Radiological Monitoring (RENAMORA) project was initiated with the support of the IAEA through MEX9/049 project and its purpose is to have a network of instruments that automatically and in real time, transmit information of the gamma radiological environmental status of the national territory and changes occurring in it. This network provides data such as the speed of ambient dose equivalent, temperature and humidity in different regions of the country. The network is composed of 92 stations that are distributed throughout the national territory. The structure of the stations has evolved since its inception, now allowing detection tasks, data transmission and managing them remotely from the main server, which is located in the CNSNS, which is performed a statistical dose for each monitoring station. Each monitoring station is formed in its current structure by a probe detection of gamma radiation, a communication module and associated electronics, a mini Web server DataGATE, a cellular modem and an interface converter. (Author)

  9. Establishing a mobile automatic monitoring station for emergency response

    International Nuclear Information System (INIS)

    Fang, Hsin-Fa

    2008-01-01

    Full text: A radiological/nuclear emergency event may cause environmental contamination. The emergency response works always need to plan an environmental survey programme incorporating the assessment results to see what is happening. The places where are assessed to have the highest radioactive contamination/radiation dose will catch more concern and need continuous monitoring. It will cause unnecessary dangers and dose to command that personnel conduct surveying in such places when the radiological/nuclear accident become more severe. A mobile automatic monitoring station has been established for emergency response by INER (Institute of Nuclear Energy Research) to solve the problem practically. The monitoring station involves a HPIC to monitor radiation dose, an anemometer to monitor wind speed and direction, a GPS to get position data, a GPRS/3G communication module to send monitoring and positioning data to the monitoring centre where can show the monitoring result directly on a map shown on the computer. These instruments are integrated in a trailer easy to be towed to the place need to be monitored. The electric power of the station is supplied by s a solar power energy system. It can supply the station working at least 10 days without extra electric power supply designed based on the expected time length of a nuclear power plant event. The HPIC is very sensitive and stable that can discriminate a 10 nSv/hr increasing of dose rate with the monitoring time period every ten seconds. Where the radiological dispersion device events happened is not predictable, it is difficult to get suitable wind monitoring data to assess the result of radiological dispersion device events. The anemometer added on the station can provide the real time wind monitoring data to help assessment works. (author)

  10. Localization of Gamma-Ray Bursts Using the Fermi Gamma-Ray Burst Monitor

    NARCIS (Netherlands)

    Connaughton, V.; Briggs, M.S.; Goldstein, A.; Meegan, C.A.; Paciesas, W.S.; Preece, R.D.; Wilson-Hodge, C.A.; Gibby, M.H.; Greiner, J.; Gruber, D.; Jenke, P.; Kippen, R.M.; Pelassa, V.; Xiong, S.; Yu, H-F.; Bhat, P.N.; Burgess, J.M.; Byrne, D.; Fitzpatrick, G.; Foley, S.; Giles, M.M.; Guiriec, S.; van der Horst, A.J.; von Kienlin, A.; McBreen, S.; McGlynn, S.; Tierney, D.; Zhang, B..B.

    2015-01-01

    The Fermi Gamma-ray Burst Monitor (GBM) has detected over 1400 gamma-ray bursts (GRBs) since it began science operations in 2008 July. We use a subset of over 300 GRBs localized by instruments such as Swift, the Fermi Large Area Telescope, INTEGRAL, and MAXI, or through triangulations from the

  11. Connection of automatic integral multichannel monitor of aerosol concentration

    International Nuclear Information System (INIS)

    Krejci, M.; Stulik, P.

    1985-01-01

    The instrument consists of the actual aerosol concentration monitor with two equivalent inputs, of an electropneumatic sampling selector, an aerosol pump, an electropneumatic valve, and of an exhaust device. For integral operating mode the instrument allows rapid checking and indication of exceedance of the permissible aerosol concentration limit at any sampling point. Upon exceedance of the permissible concentration limit, the device automatically switches into the multichannel cyclic measurement mode while the sampling point is identified where the aerosol concentration was increased. An emergency is displayed if the permissible limit has been exceeded. Following removal of the source of dangerous aerosol concentration, the control unit automatically switches the device into the integral measurement mode. (J.B.)

  12. Automatic gamma radiation scanning device and feed mechanism for plural sample holders

    International Nuclear Information System (INIS)

    Byrd, W.J.

    1976-01-01

    Apparatus is disclosed for measuring the level of gamma radiation contained in a plurality of biological samples which are located on the fibrous sheet member carried by a sample holder. The apparatus is adapted to count the radiation level of the number of closely spaced samples located in rows and columns on the sheet by automatically sequencing through the individual samples within the rows and to advance the holder to bring successive rows into proximity with the detector. The detector is moved from sample to sample within the rows, although a number of detectors can be employed. A plurality of sample holders are automatically advanced to the detector. 25 claims, 5 drawing figures

  13. Microwave-gamma ray water in crude monitor

    International Nuclear Information System (INIS)

    Paap, H.J.

    1984-01-01

    A microwave-gamma ray water-in-crude monitoring system measures the percent quantity of fresh water or salt water in crude oil flowing in a pipe line. The system includes a measuring cell arranged with the pipe line so that the crude oil flows through the measuring cell. A microwave transmitter subsystem and a gamma ray source are arranged with the measuring cell so that microwave energy and gamma rays are transmitted through the measuring cell. A microwave receiving subsystem and a gamma ray detector provide signals corresponding to received microwave energy and to the received gamma rays, respectively. Apparatus connected to the microwave receiver and to the gamma ray detector provides an indication of the percentage of water in the crude oil

  14. Influence of the temperature in the measurement of the gamma automatic probe Gamma Tracer

    International Nuclear Information System (INIS)

    Caveda R, C.A.; Dominguez L, O.; Alonso A, D.; Montalvan E, A.; Fabelo B, O.

    2006-01-01

    In the following work an analysis of the existent relationship among the measurement of the absorbed dose rate in air due to the environmental gamma radiation and the temperature, magnitudes measured to intervals of 10 minutes by the gamma probe Gamma Tracer located in the post of occident of the National Net of Environmental Radiological Surveillance (RNVRA), in the Center of Protection and Hygiene of the Radiations (CPHR) is made. For it its were analyzed near 100,000 measurements corresponding to the period 2004-2005. For a better processing and interpretation of the data, these were analyzed with one frequency time zone and monthly using the Gamma Red software to which was necessary to add it some options. Finally it was submitted the probe to a heating process inside a stove. The results of the carried out experiments confirmed that the absorbed dose rate in air due to the environmental gamma radiation depends potentially of the probe temperature in the range of environmental temperature to which is subjected daily the same one. (Author)

  15. Study on intermediate frequency power supply automatic monitor system

    International Nuclear Information System (INIS)

    Wang Yuntong; Xu Bin

    2007-06-01

    A new design project of the automatic monitor system for the intermediate frequency power supply system by using the communication server is put for- ward and the realizing principle method and the key technique are clarified in detail. This system made use of the conversion function with the series communication server's control, realized the data collecting function by the double machine backup and redundancy. The new network system adopted the photoelectric-insulated-communication connect device and the diagnosis technique, increased the anti-interference ability, the communication adopted the technique by the alarm information sending out in first and circularly repeating, the slowly speed is overcame in the original monitor network system, and strengthened the celerity of the monitor system and the reliability of the alarm report. After the new monitor system running, the result shows that the functions is more perfect than the original monitor system, the usage is more convenient, have the higher and dependable stability, the report of alarm is more quickly, and is convenient for the analysis after the trouble, at the same time, the system still have the strong ability and value to expand. (authors)

  16. Method for monitoring drilling materials for gamma ray activity

    International Nuclear Information System (INIS)

    Smith, H.D. Jr.; Arnold, D.M.; Schultz, W.E.

    1985-01-01

    In the preferred and illustrated embodiment taught herein, method steps for monitoring of raw materials to be used in drilling mud are disclosed. The materials are monitored for radioactivity. Procedures for taking such measurements are disclosed, and the extent of gamma radioactivity in the raw materials used in drilling mud is, determined. This is correlated to the increased radiation attributable to mud made from these materials and the effect the mud would have on gamma ray measuring logs. An alternate procedure for testing drilling mud, typically at the well site, is also disclosed. The method detects mud radioactivity from any additives including barite, potassium chloride, well cuttings or others. Excessive background levels due to mud gamma radioactivity in a well may very well mask the data obtained by various logging procedures dependent on gamma radiation. Procedures are also described for either rejecting mud which is too radioactive or correcting the log measurements for mud effects

  17. Design and Implementation of a Modern Automatic Deformation Monitoring System

    Science.gov (United States)

    Engel, Philipp; Schweimler, Björn

    2016-03-01

    The deformation monitoring of structures and buildings is an important task field of modern engineering surveying, ensuring the standing and reliability of supervised objects over a long period. Several commercial hardware and software solutions for the realization of such monitoring measurements are available on the market. In addition to them, a research team at the University of Applied Sciences in Neubrandenburg (NUAS) is actively developing a software package for monitoring purposes in geodesy and geotechnics, which is distributed under an open source licence and free of charge. The task of managing an open source project is well-known in computer science, but it is fairly new in a geodetic context. This paper contributes to that issue by detailing applications, frameworks, and interfaces for the design and implementation of open hardware and software solutions for sensor control, sensor networks, and data management in automatic deformation monitoring. It will be discussed how the development effort of networked applications can be reduced by using free programming tools, cloud computing technologies, and rapid prototyping methods.

  18. CERPI and CEREL, two computer codes for the automatic identification and determination of gamma emitters in thermal neutron activated samples

    International Nuclear Information System (INIS)

    Giannini, M.; Oliva, P.R.; Ramorino, C.

    1978-01-01

    A description is given of a computer code which automatically analyses gamma-ray spectra obtained with Ge(Li) detectors. The program contains features as automatic peak location and fitting, determination of peak energies and intensities, nuclide identification and calculation of masses and errors. Finally the results obtained with our computer code for a lunar sample are reported and briefly discussed

  19. An automatic monitoring system of leak current for testing TGC detectors based on LabVIEW

    International Nuclear Information System (INIS)

    Feng Cunfeng; Lu Taiguo; Yan Zhen; Wang Suojie; Zhu Chengguang; Sun Yansheng; He Mao

    2005-01-01

    An automatic monitoring system of leak current for testing TGC detectors with high voltage was set up by using the graphic LabVIEW platform and NI 4351 data acquisition card. The leak current was automatically monitored and recorded with this system, the time and the value of the leak current were showed instantly. Good efficiency and precision of monitoring were obtained. (authors)

  20. Automatic visual monitoring of welding procedure in stainless steel kegs

    Science.gov (United States)

    Leo, Marco; Del Coco, Marco; Carcagnì, Pierluigi; Spagnolo, Paolo; Mazzeo, Pier Luigi; Distante, Cosimo; Zecca, Raffaele

    2018-05-01

    In this paper a system for automatic visual monitoring of welding process, in dry stainless steel kegs for food storage, is proposed. In the considered manufacturing process the upper and lower skirts are welded to the vessel by means of Tungsten Inert Gas (TIG) welding. During the process several problems can arise: 1) residuals on the bottom 2) darker weld 3) excessive/poor penetration and 4) outgrowths. The proposed system deals with all the four aforementioned problems and its inspection performances have been evaluated by using a large set of kegs demonstrating both the reliability in terms of defect detection and the suitability to be introduced in the manufacturing system in terms of computational costs.

  1. Automatic processing of gamma ray spectra employing classical and modified Fourier transform approach

    International Nuclear Information System (INIS)

    Rattan, S.S.; Madan, V.K.

    1994-01-01

    This report describes methods for automatic processing of gamma ray spectra acquired with HPGe detectors. The processing incorporated both classical and signal processing approach. The classical method was used for smoothing, detecting significant peaks, finding peak envelope limits and a proposed method of finding peak limits, peak significance index, full width at half maximum, detecting doublets for further analysis. To facilitate application of signal processing to nuclear spectra, Madan et al. gave a new classification of signals and identified nuclear spectra as Type II signals, mathematically formalized modified Fourier transform and pioneered its application to process doublet envelopes acquired with modern spectrometers. It was extended to facilitate routine analysis of the spectra. A facility for energy and efficiency calibration was also included. The results obtained by analyzing observed gamma-ray spectra using the above approach compared favourably with those obtained with SAMPO and also those derived from table of radioisotopes. (author). 15 refs., 3 figs., 3 tabs

  2. Gamma monitoring system 'Hyperion' at the research nuclear reactor RB

    International Nuclear Information System (INIS)

    Zigic, A.; Saponjic, Dj.; Arandelovic, V. . E-mail address of corresponding author: alex@vin.bg.ac.yu

    2005-01-01

    While performing experiments at the research reactor RB at Vinca institute it is mandatory to measure the intensity of gamma radiation at reactor RB since the reactor has no biological protection. the stationary distributed measurement system 'Hyperion' implemented at reactor RB, performs measurements and monitoring of gamma radiation at 10 specified measuring sites within and in the vicinity of the reactor RB in the required absorbed dose in air range of 50 nGy/h to 10 mGy/h. the 'Hyperion' monitoring system have three hierarchically organized layers. the basic layer consists of the network of 10 intelligent gm probes located at predetermined measuring sites. the medium layer represents the PC-based local control node where measured data from all intelligent probes are separately acquired, stored in the local database and processed for local visualization and printed measurements reports for network operator. the information on the status of the intelligent gm probes are also provided, enabling the verification of measured results at the local control node. the central control node represents the pc-based highest monitoring network layer connected to the local control node using already existing lan infrastructure. the central control node hosts the central database, provides full insight into instantaneous gamma radiation levels at all measuring sites, provides archives on daily bases for all monitored locations and printed reports on measurements for all measuring sites at any time of gamma radiation measurement. (author)

  3. Usage of aids monitoring in automatic braking systems of modern cars

    OpenAIRE

    Dembitskyi V.; Mazylyuk P.; Sitovskyi O.

    2016-01-01

    Increased safety can be carried out at the expense the installation on vehicles of automatic braking systems, that monitor the traffic situation and the actions of the driver. In this paper considered the advantages and disadvantages of automatic braking systems, were analyzed modern tracking tools that are used in automatic braking systems. Based on the statistical data on accidents, are set the main dangers, that the automatic braking system will be reduced. In order to ensure the acc...

  4. Study of medical isotope production facility stack emissions and noble gas isotopic signature using automatic gamma-spectra analysis platform

    Science.gov (United States)

    Zhang, Weihua; Hoffmann, Emmy; Ungar, Kurt; Dolinar, George; Miley, Harry; Mekarski, Pawel; Schrom, Brian; Hoffman, Ian; Lawrie, Ryan; Loosz, Tom

    2013-04-01

    The nuclear industry emissions of the four CTBT (Comprehensive Nuclear-Test-Ban Treaty) relevant radioxenon isotopes are unavoidably detected by the IMS along with possible treaty violations. Another civil source of radioxenon emissions which contributes to the global background is radiopharmaceutical production companies. To better understand the source terms of these background emissions, a joint project between HC, ANSTO, PNNL and CRL was formed to install real-time detection systems to support 135Xe, 133Xe, 131mXe and 133mXe measurements at the ANSTO and CRL 99Mo production facility stacks as well as the CANDU (CANada Deuterium Uranium) primary coolant monitoring system at CRL. At each site, high resolution gamma spectra were collected every 15 minutes using a HPGe detector to continuously monitor a bypass feed from the stack or CANDU primary coolant system as it passed through a sampling cell. HC also conducted atmospheric monitoring for radioxenon at approximately 200 km distant from CRL. A program was written to transfer each spectrum into a text file format suitable for the automatic gamma-spectra analysis platform and then email the file to a server. Once the email was received by the server, it was automatically analysed with the gamma-spectrum software UniSampo/Shaman to perform radionuclide identification and activity calculation for a large number of gamma-spectra in a short period of time (less than 10 seconds per spectrum). The results of nuclide activity together with other spectrum parameters were saved into the Linssi database. This database contains a large amount of radionuclide information which is a valuable resource for the analysis of radionuclide distribution within the noble gas fission product emissions. The results could be useful to identify the specific mechanisms of the activity release. The isotopic signatures of the various radioxenon species can be determined as a function of release time. Comparison of 133mXe and 133Xe activity

  5. Development of technique for quantifying gamma emitters in metal waste. New technique of precise and automatic measurements for confirmation of clearance level of metal waste

    International Nuclear Information System (INIS)

    Hattori, Takatoshi

    2002-01-01

    A New technique of precise and automatic measurements of gamma emitters in metal waste has been developed using 3D non-contact shape measurement and monte-carlo calculation techniques in order to confirm that specific radioactivity level of metal waste satisfies the clearance level and furthermore the surface contamination level of the metal waste is below the legal standard level. The technique can give a calibration factor every measurement target automatically and realize an automatic correction for reduction of background count rate in gamma measurements due to self-shield effect of the measurement target. The accuracy of the present method has been made clear using mock-metal wastes with various types of shape, number and size. Assuming the goal of the detection limit for practical use is 25OBq in radioactivity, a concept of the practical gamma monitor has been designed so as to be able to confirm both the clearance level and surface contamination level simultaneously and to cope with the metal waste at a speed of 2-10 ton a day. (author)

  6. Focused attention, open monitoring and automatic self-transcending: Categories to organize meditations from Vedic, Buddhist and Chinese traditions.

    Science.gov (United States)

    Travis, Fred; Shear, Jonathan

    2010-12-01

    This paper proposes a third meditation-category--automatic self-transcending--to extend the dichotomy of focused attention and open monitoring proposed by Lutz. Automatic self-transcending includes techniques designed to transcend their own activity. This contrasts with focused attention, which keeps attention focused on an object; and open monitoring, which keeps attention involved in the monitoring process. Each category was assigned EEG bands, based on reported brain patterns during mental tasks, and meditations were categorized based on their reported EEG. Focused attention, characterized by beta/gamma activity, included meditations from Tibetan Buddhist, Buddhist, and Chinese traditions. Open monitoring, characterized by theta activity, included meditations from Buddhist, Chinese, and Vedic traditions. Automatic self-transcending, characterized by alpha1 activity, included meditations from Vedic and Chinese traditions. Between categories, the included meditations differed in focus, subject/object relation, and procedures. These findings shed light on the common mistake of averaging meditations together to determine mechanisms or clinical effects. Copyright © 2010 Elsevier Inc. All rights reserved.

  7. System for continuous real time air monitoring by means of gamma spectrometry with germanium dosimeter; Sistema di monitoraggio dell'aria in continuo mediante spettrometria gamma con rilevatore al germanio

    Energy Technology Data Exchange (ETDEWEB)

    Montalto, M; Giacomelli, R; Nocente, M; Bortoluzzi, S; Spezzano, P [ENEA - Area Energia, Ambiente e Salute, Centro Ricerche Energia Saluggia, Vercelli (Italy)

    1990-12-15

    Design of automatic system for real time air monitoring of radioactive particulates are relate. Recommendations are made for design and operation of sampling conduits to minimize losses. By means of experimental equipment loss of particles in long sampling conduits, minimum detectable activity and efficiency of gamma radiation detectable are evaluated. (author)

  8. Automatic optimisation of gamma dose rate sensor networks: The DETECT Optimisation Tool

    DEFF Research Database (Denmark)

    Helle, K.B.; Müller, T.O.; Astrup, Poul

    2014-01-01

    of the EU FP 7 project DETECT. It evaluates the gamma dose rates that a proposed set of sensors might measure in an emergency and uses this information to optimise the sensor locations. The gamma dose rates are taken from a comprehensive library of simulations of atmospheric radioactive plumes from 64......Fast delivery of comprehensive information on the radiological situation is essential for decision-making in nuclear emergencies. Most national radiological agencies in Europe employ gamma dose rate sensor networks to monitor radioactive pollution of the atmosphere. Sensor locations were often...... source locations. These simulations cover the whole European Union, so the DOT allows evaluation and optimisation of sensor networks for all EU countries, as well as evaluation of fencing sensors around possible sources. Users can choose from seven cost functions to evaluate the capability of a given...

  9. Environmental gamma radiation monitoring at Visakhapatnam using thermoluminescence dosimeters

    International Nuclear Information System (INIS)

    Swarnkar, M.; Sahu, S.K.; Takale, R.A.; Shetty, P.G.; Pundit, G.G.; Puranik, V.D.

    2012-01-01

    The gamma rays are the most significant part of environmental dose due to its large range and deep penetrating power. The environmental gamma radiation is mainly originated from two sources natural radiation and artificially produced radiation. The natural radiation dose arises from the cosmic radiation (galactic and solar) and from the Earth (terrestrial) surface. In the last few decades there is a growing concern all over the world about radiation and their exposure to population. Thus it is necessary to conduct radiological environmental surveillance. The radiation survey data are useful to establish the natural background gamma radiation levels. Extensive gamma radiation survey was carried out around the surroundings of Vishakhapatnam using Thermoluminescence Dosimeters (TLDs). The CaSO 4 :(0.2 mole %) Dy Teflon TLD discs, specifically designed for environmental gamma radiation monitoring purpose were used. These TLD badge are having very high TL sensitivity, a negligible fading rate and a stable TL response. TLDs were deployed on quarterly basis for two years to obtain the cumulative gamma background radiation levels in the study area. The radiological survey was also carried out by using a calibrated radiation survey meter. The annual dose rates were computed from quarterly values actually found and normalised to 365 days. The environmental gamma radiation levels around Vishakhapatnam were found to be in the range of 0.79 mGy/y to 1.86 mGy/y. It is clearly seen from the results that location to location there is a large variation in external gamma radiation levels. During the cycle of the TLD survey, spot readings of the background radiation levels were taken, both while placing the TLDs and while removing them. The instantaneous dose rates measured using survey meter, are also following the large variation as found in TLDs. It varies between 110 nGy/hr to 210 nGy/hr. (author)

  10. Energy Management for Automatic Monitoring Stations in Arctic Regions

    Science.gov (United States)

    Pimentel, Demian

    Automatic weather monitoring stations deployed in arctic regions are usually installed in hard to reach locations. Most of the time they run unsupervised and they face severe environmental conditions: very low temperatures, ice riming, etc. It is usual practice to use a local energy source to power the equipment. There are three main ways to achieve this: (1) a generator whose fuel has to be transported to the location at regular intervals (2) a battery and (3) an energy harvesting generator that exploits a local energy source. Hybrid systems are very common. Polar nights and long winters are typical of arctic regions. Solar radiation reaching the ground during this season is very low or non-existent, depending on the geographical location. Therefore, solar power generation is not very effective. One straightforward, but expensive and inefficient solution is the use of a large bank of batteries that is recharged during sunny months and discharged during the winter. The main purpose of the monitoring stations is to collect meteorological data at regular intervals; interruptions due to a lack of electrical energy can be prevented with the use of an energy management subsystem. Keeping a balance between incoming and outgoing energy flows, while assuring the continuous operation of the station, is the delicate task of energy management strategies. This doctoral thesis explores alternate power generation solutions and intelligent energy management techniques for equipment deployed in the arctic. For instance, harvesting energy from the wind to complement solar generation is studied. Nevertheless, harvested energy is a scarce resource and needs to be used efficiently. Genetic algorithms, fuzzy logic, and common sense are used to efficiently manage energy flows within a simulated arctic weather station.

  11. National automatic network of environmental radiological monitoring (RENAMORA)

    International Nuclear Information System (INIS)

    Gonzalez M, J.L.; Sanchez H, L.

    2003-01-01

    Inside the programs of Environmental Radiological Surveillance that it carries out the National Commission of Nuclear Security and Safeguards (CNSNS), it develops an National Automatic Network of Environmental Radiological Monitoring (RENAMORA), where it is carried out a registration of speed of environmental dose in continuous and simultaneous forms with the same moment of the measurement. This net allows to account with the meticulous and opportune information that will help to characterize, in dynamics form, the radiological conditions of diverse geographical zones of the country, including the sites that by normative require bigger surveillance, like its are the Laguna Verde Nuclear power station (CNLV), the Nuclear Center of Mexico (ININ) and the Radioactive waste storage center (CADER). This net is in its first development stage; three points inside the state of Veracruz, in the surroundings of the CNLV, already its are operating; the obtained data of rapidity of environmental dose are being stored in a database inside a primary data center located in the facilities of the CNSNS in Mexico city and its will be analyzed according to the project advances. At the moment, its are installing the first ten teams corresponding to the first phase of the RENAMORA (three stages); its are carried out operation tests, transmission, reception and administration of data. The obtained data will be interpreted, analyzed and inter compared to evaluate the risk levels to that it would be hold the population and to determine thresholds that allow to integrate the alarm systems that its had considered for emergency situations. (Author)

  12. Risk analysis of Leksell Gamma Knife Model C with automatic positioning system

    International Nuclear Information System (INIS)

    Goetsch, Steven J.

    2002-01-01

    Purpose: This study was conducted to evaluate the decrease in risk from misadministration of the new Leksell Gamma Knife Model C with Automatic Positioning System compared with previous models. Methods and Materials: Elekta Instruments, A.B. of Stockholm has introduced a new computer-controlled Leksell Gamma Knife Model C which uses motor-driven trunnions to reposition the patient between isocenters (shots) without human intervention. Previous models required the operators to manually set coordinates from a printed list, permitting opportunities for coordinate transposition, incorrect helmet size, incorrect treatment times, missing shots, or repeated shots. Results: A risk analysis was conducted between craniotomy involving hospital admission and outpatient Gamma Knife radiosurgery. A report of the Institute of Medicine of the National Academies dated November 29, 1999 estimated that medical errors kill between 44,000 and 98,000 people each year in the United States. Another report from the National Nosocomial Infections Surveillance System estimates that 2.1 million nosocomial infections occur annually in the United States in acute care hospitals alone, with 31 million total admissions. Conclusions: All medical procedures have attendant risks of morbidity and possibly mortality. Each patient should be counseled as to the risk of adverse effects as well as the likelihood of good results for alternative treatment strategies. This paper seeks to fill a gap in the existing medical literature, which has a paucity of data involving risk estimates for stereotactic radiosurgery

  13. Environmental monitoring with in-situ gamma spectrometer; Umweltueberwachung mit in-situ-Gamma-Spektrometer

    Energy Technology Data Exchange (ETDEWEB)

    Reinhardt, S. [ENVINET GmbH, Haar (Germany)

    2014-01-20

    The in-situ gamma spectroscopy allows large area and continuous monitoring of the radio nuclides and there composition in the environment. In comparison to the gamma dose rate measurement the additional spectral information gives the possibility for a quick and effective action in the case of a man-made radiation exposition in the environment. The knowledge respectively localization of the possible nuclides, which a responsible for the increased dose rate, supports responsible organization in the quick identification of the situation, definition of the actions and tracking of the temporal and local process of the radiation exposition. Due to dedicate actions the risk for people and environment is reduced.

  14. Quality assurance of environmental gamma radiation monitoring in Slovenia

    International Nuclear Information System (INIS)

    Stuhec, M.; Zorko, B.; Mitic, D.; Miljanic, S.; Ranogajec-Komor, M.

    2006-01-01

    Environmental gamma radiation monitoring established in Slovenia consists of a network of multifunctional gamma monitors (MFMs) based on pairs of Geiger-Mueller counters and a network of measuring sites with high-sensitive thermoluminescence dosemeters. The measuring points are evenly spread across Slovenia, located at the meteorological stations and more densely on additional locations around the Krsko NPP. The MFM network has a 2-fold function with one sensor used for the purpose of early warning system in near surroundings of the NPP and the other, more sensitive, for natural radiation monitoring. The paper summarises activities to establish quality assurance of the environmental gamma radiation measurements in Slovenia, with a critical view of the results in comparison with the international standards and recommendations. While the results of linearity and energy dependence tests were satisfying, on-field intercomparison showed that the inherent signal of one of the monitors (MFM) has to be taken into account in the range of environmental background radiation. (authors)

  15. Sodium fast reactor power monitoring using gamma spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Coulon, R.; Normand, S.; Barbot, L.; Domenech, T.; Kondrasovs, V.; Corre, G.; Frelin, A.M. [CEA, LIST, Laboratoire Capteurs et Architectures Electroniques, CEA - Saclay DRT/LIST/DETECS/SSTM, Batiment 516 - P.C. no 72, Gif sur Yvette, F-91191 (France); Montagu, T.; Dautremer, T.; Barat, E. [CEA, LIST, Laboratoire Processus Stochastiques et Spectres (France); Ban, G. [ENSICAEN (France)

    2009-06-15

    This work deals with the use of high flux gamma spectrometry to monitor the fourth generation of sodium fast reactor (SFR) power. The simulation study part of this work has shown that power monitoring in a short time response and with a good accuracy is possible. An experimental test is under preparation at the French SFR Phenix experimental reactor to validate simulation studies. First, physical calculations have been done to correlate gamma activity to the released thermal power. Gamma emitter production rate in the reactor core was calculated with technical and nuclear data as the sodium velocity, the atomic densities, Phenix neutron spectrum and incident neutron cross-sections of reactions producing gamma emitters. A thermal hydraulic transfer function was used for modeling primary sodium flow in our calculations. For the power monitoring problematic, use of a short decay period gamma emitter will allow to have a very fast response system without cumulative effect. We have determined that the best tagging agent is 20F which emits 1634 keV energy photons with a decay period of 11 s. The gamma spectrum was determined by flux point and a pulse high tally MCNP5.1.40 simulation and shown the possibility to measure the signal of this radionuclide. The experiment will be set during the reactor 'end life testing'. The Delayed Neutron Detection (DND) room has been chosen as the best available location on Phenix reactor to measure this kind of radionuclide due to a short transit time from reactor core to measurement sample. This location is optimum for global power measurement because homogenized sampling in the reactor hot pool. The main spectrometer is composed of a coaxial high purity germanium diode (HPGe) coupled with a transistor reset preamplifier. The HPGe diode signal will be processed by the Adonis digital signal processing due to high flux and fast activity measurement. Post-processing softwares will be used to limit statistical problems of the

  16. System of message for gamma-radiation monitor

    International Nuclear Information System (INIS)

    Bolic, M.D.; Koturovic, A.M.

    2001-01-01

    Paper describes a system of voice messages for gamma-radiation monitor based on PC. The systems reproduces recorded messages that is simpler than the process of their synthesis. Message choice is based on combination of recorded digital results and/or received reference messages or warnings. The system of generation of voice messages applies the Windows based software. The total memory array required to create independent voice system is maximum 1.7 mbyte. The monitor may be used for continuous monitoring of radioactivity level with 5-8 s period of message repetition. Another option of the system operation is based on monitor application for the environment monitoring. Period of messages in this case is equal to 5-30 min [ru

  17. Continuous monitoring system for environmental {gamma} radiation near nuclear facility

    Energy Technology Data Exchange (ETDEWEB)

    Hua, Jin; Qingyu, Yue; Wenhai, Wang [Academia Sinica, Beijing, BJ (China). Inst. of Atomic Energy

    1996-06-01

    The continuous monitoring system which is used for the environmental routine and accident emergency {gamma} radiation monitoring near nuclear facility is described. The continuous monitoring system consists of a high pressurized ionization chamber, integrated weak current amplifier, V/F converter and intelligent data recorder. The data gained by recorder can be transmitted to a PC through a standard RS-232-C interface for the data handling and graph plotting. This continuous monitoring system has the functions of alarm over threshold and recorded output signal of detector and temperature. The measuring range is from 10 nGy{center_dot}h{sup -1} to 10 mGy{center_dot}h{sup -1} because a high insulation switch atomically changed measuring ranges is used. The monitoring system has been operating continuously for a long time with high stability and reliability. (5 figs., 2 tabs.).

  18. Modeling and monitoring of pipelines and networks advanced tools for automatic monitoring and supervision of pipelines

    CERN Document Server

    Torres, Lizeth

    2017-01-01

    This book focuses on the analysis and design of advanced techniques for on-line automatic computational monitoring of pipelines and pipe networks. It discusses how to improve the systems’ security considering mathematical models of the flow, historical flow rate and pressure data, with the main goal of reducing the number of sensors installed along a pipeline. The techniques presented in the book have been implemented in digital systems to enhance the abilities of the pipeline network’s operators in recognizing anomalies. A real leak scenario in a Mexican water pipeline is used to illustrate the benefits of these techniques in locating the position of a leak. Intended for an interdisciplinary audience, the book addresses researchers and professionals in the areas of mechanical, civil and control engineering. It covers topics on fluid mechanics, instrumentation, automatic control, signal processing, computing, construction and diagnostic technologies.

  19. Fault diagnosis method for area gamma monitors in Nuclear Facilities

    International Nuclear Information System (INIS)

    Srinivas Reddy, P.; Amudhu Ramesh Kumar, R.; Geo Mathews, M.; Amarendra, G.

    2016-01-01

    Area Gamma Monitors (AGM) using Geiger-Muller (GM) counter are deployed in nuclear facilities for detection of gamma radiation. The AGMs display the dose rate locally and in Data Acquisition System (DAS) at central monitoring station. It also provides local visual and audio alarms in case of dose rate exceeding alarm set point. Regular surveillance checking, testing and calibration of AGMs are mandatory as per safety guidelines. This paper describes quick testing the AGMs without using radioactive source. The four point High Voltages (HV) and Discriminator Bias (DB) voltage characteristics are used to diagnose the state of health of GM counter. The profiles of HV and DB voltage are applied during testing of the AGMs

  20. Development of radiation safety monitoring system at gamma greenhouse gamma facility

    International Nuclear Information System (INIS)

    Hairul Nizam Idris; Azimawati Ahmad, Ahmad Zaki Hussain; Ahmad Fairuz Mohd Nasir

    2009-01-01

    This paper is discussing about installation of radiation safety monitoring system at Gamma Greenhouse Gamma facility, Agrotechnology and Bioscience Division (BAB). This facility actually is an outdoor type irradiation facility, which first in Nuclear Malaysia and the only one in Malaysia. Source Cs-137 (801 Curie) was use as radiation source and it located at the centre of 30 metres diameter size of open irradiation area. The radiation measurement and monitoring system to be equipped in this facility were required the proper equipment and devices, specially purpose for application at outside of building. Research review, literature study and discussion with the equipment manufacturers was being carried out, in effort to identify the best system should be developed. Factors such as tropical climate, environment surrounding and security were considered during selecting the proper system. Since this facility involving with panoramic radiation type, several critical and strategic locations have been fixed with radiation detectors, up to the distance at 200 meter from the radiation source. Apart from that, this developed system also was built for capable to provide the online real-time reading (using internet). In general, it can be summarized that the radiation safety monitoring system for outdoor type irradiation facility was found much different and complex compared to the system for indoor type facility. Keyword: radiation monitoring, radiation safety, Gamma Greenhouse, outdoor irradiation facility, panoramic radiation. (Author)

  1. Application of gamma-ray spectroscopy in environmental monitoring

    International Nuclear Information System (INIS)

    Hobbs, B.B.; Kanipe, L.G.; Clayton, W.R.; Belvin, E.A.

    1976-01-01

    Gamma-ray spectroscopy is used as the primary analytical method in the Tennessee Valley Authority's environmental radiation monitoring program. Routine sample screening is done by means of least-squares analysis of spectra from NaI(Tl) detectors. Nonroutine or suspicious samples are analyzed by means of Ge(Li) spectral analysis. A laboratory quality control program provides internal and external checks on the reliability of analyses

  2. Integrated neutron/gamma-ray portal monitors for nuclear safeguards

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1994-01-01

    Radiation monitoring is one nuclear-safeguards measure used to protect against the theft of special nuclear materials (SNM) by pedestrians departing from SNM access areas. The integrated neutron/gamma-ray portal monitor is an ideal radiation monitor for the task when the SNM is plutonium. It achieves high sensitivity for detecting both bare and shielded plutonium by combining two types of radiation detector. One type is a neutron-chamber detector, comprising a large, hollow, neutron moderator that contains a single thermal-neutron proportional counter. The entrance wall of each chamber is thin to admit slow neutrons from plutonium contained in a moderating shield, while the other walls are thick to moderate fast neutrons from bare or lead-shielded plutonium so that they can be detected. The other type of detector is a plastic scintillator that is primarily for detecting gamma rays from small amounts of unshielded plutonium. The two types of detector are easily integrated by making scintillators part of the thick back wall of each neutron chamber or by inserting them into each chamber void. The authors compared the influence of the two methods of integration on detecting neutrons and gamma rays, and they examined the effectiveness of other design factors and the methods for signal detection as well

  3. Development of autonomous gamma dose logger for environmental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Jisha, N. V.; Krishnakumar, D. N.; Surya Prakash, G.; Kumari, Anju; Baskaran, R.; Venkatraman, B. [Radiological Safety Division, Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102, Tamil Nadu (India)

    2012-03-15

    Continuous monitoring and archiving of background radiation levels in and around the nuclear installation is essential and the data would be of immense use during analysis of any untoward incidents. A portable Geiger Muller detector based autonomous gamma dose logger (AGDL) for environmental monitoring is indigenously designed and developed. The system operations are controlled by microcontroller (AT89S52) and the main features of the system are software data acquisition, real time LCD display of radiation level, data archiving at removable compact flash card. The complete system operates on 12 V battery backed up by solar panel and hence the system is totally portable and ideal for field use. The system has been calibrated with Co-60 source (8.1 MBq) at various source-detector distances. The system is field tested and performance evaluation is carried out. This paper covers the design considerations of the hardware, software architecture of the system along with details of the front-end operation of the autonomous gamma dose logger and the data file formats. The data gathered during field testing and inter comparison with GammaTRACER are also presented in the paper. AGDL has shown excellent correlation with energy fluence monitor tuned to identify {sup 41}Ar, proving its utility for real-time plume tracking and source term estimation.

  4. Development of autonomous gamma dose logger for environmental monitoring.

    Science.gov (United States)

    Jisha, N V; Krishnakumar, D N; Surya Prakash, G; Kumari, Anju; Baskaran, R; Venkatraman, B

    2012-03-01

    Continuous monitoring and archiving of background radiation levels in and around the nuclear installation is essential and the data would be of immense use during analysis of any untoward incidents. A portable Geiger Muller detector based autonomous gamma dose logger (AGDL) for environmental monitoring is indigenously designed and developed. The system operations are controlled by microcontroller (AT89S52) and the main features of the system are software data acquisition, real time LCD display of radiation level, data archiving at removable compact flash card. The complete system operates on 12 V battery backed up by solar panel and hence the system is totally portable and ideal for field use. The system has been calibrated with Co-60 source (8.1 MBq) at various source-detector distances. The system is field tested and performance evaluation is carried out. This paper covers the design considerations of the hardware, software architecture of the system along with details of the front-end operation of the autonomous gamma dose logger and the data file formats. The data gathered during field testing and inter comparison with GammaTRACER are also presented in the paper. AGDL has shown excellent correlation with energy fluence monitor tuned to identify (41)Ar, proving its utility for real-time plume tracking and source term estimation.

  5. Research progress of on-line automatic monitoring of chemical oxygen demand (COD) of water

    Science.gov (United States)

    Cai, Youfa; Fu, Xing; Gao, Xiaolu; Li, Lianyin

    2018-02-01

    With the increasingly stricter control of pollutant emission in China, the on-line automatic monitoring of water quality is particularly urgent. The chemical oxygen demand (COD) is a comprehensive index to measure the contamination caused by organic matters, and thus it is taken as one important index of energy-saving and emission reduction in China’s “Twelve-Five” program. So far, the COD on-line automatic monitoring instrument has played an important role in the field of sewage monitoring. This paper reviews the existing methods to achieve on-line automatic monitoring of COD, and on the basis, points out the future trend of the COD on-line automatic monitoring instruments.

  6. Data Quality Monitoring : Automatic MOnitoRing Environment (AMORE ) Web Administration Tool in ALICE Experiment

    CERN Document Server

    Nagi, Imre

    2013-01-01

    ALICE (A Large Ion Collider Experiment) is the heavy-ion detector designed to study the physics of strongly interacting matter and the quark-gluon plasma at the CERN Large Hadron Collider (LHC). The quality of the acquired data evolves over time depending on the status of the detectors, its components and the operating environment. To get an excellent performance of detector, all detector configurations have to be set perfectly so that the data-taking can be done in an optimal way. This report describes a new implementation of the administration tools of the ALICE’s DQM framework called AMORE (Automatic MonitoRing Environment) with web technologies.

  7. Monitoring system for gamma radiation of porch type for vehicles

    International Nuclear Information System (INIS)

    Vazquez C, R.M.; Molina, G.; Gutierrez O, E.; Ramirez J, F.J.; Garcia H, J.M.; Aguilar B, M.A.; Vilchis P, A.E.; Cruz E, P.; Torres B, M.A.

    2005-01-01

    A monitoring system of gamma radiation for vehicles of the porch type developed in the ININ is presented. This system carries out the radiological monitoring of the vehicles in continuous form, detecting the bottom radiological environment and the presence of nuclear material transported in vehicles. The vehicles are monitored while they pass to low speed through the porch. The detectors are plastic scintillators of great volume that allow high sensibility detection. The arrangement of detecting is interconnected in net, and the data are concentrated on a personal computer whose interface man-machine can be accessed from any personal computer connected to Internet. The system monitoring in real time with options of sampling times from 50 ms configurable up to 500 ms. (Author)

  8. The Fermi Gamma-ray Burst Monitor Instrument

    International Nuclear Information System (INIS)

    Bhat, P. N.; Briggs, M. S.; Connaughton, V.; Paciesas, W. S.; Preece, R. D.; Meegan, C. A.; Lichti, G. G.; Diehl, R.; Greiner, J.; Kienlin, A. von; Fishman, G. J.; Kouveliotou, C.; Kippen, R. M.

    2009-01-01

    The Fermi Gamma-ray Space Telescope launched on June 11, 2008 carries two experiments onboard--the Large Area Telescope (LAT) and the Gamma-ray Burst Monitor (GBM). The primary mission of the GBM instrument is to support the LAT in observing γ-ray bursts (GRBs) by providing low-energy measurements with high temporal and spectral resolution as well as rapid burst locations over a large field-of-view (≥8 sr). The GBM will complement the LAT measurements by observing GRBs in the energy range 8 keV to 40 MeV, the region of the spectral turnover in most GRBs. The GBM detector signals are processed by the onboard digital processing unit (DPU). We describe some of the hardware features of the DPU and its expected limitations during intense triggers.

  9. Response of radiation monitoring labels to gamma rays and electrons

    DEFF Research Database (Denmark)

    Rahim, F. Abdel; Miller, Arne; McLaughlin, W.L.

    1985-01-01

    or location has been irradiated to high doses. Among labels available worldwide, a few are suitable for indicating absorbed dose regions of slightly less than 104 Gy (monitoring high dose ranges (i.e., sterilization dose levels of > 104 Gy or > 1 Mrad), and in some cases......, and differences in dose rate and radiation type (gamma rays and electron beams) were made on 15 kinds of labels. The results show that, for many types of indicators, diverse effects may give misleading conclusions unless countermeasures are taken. For example, some of the most commonly used labels, which contain...... permit somewhat more precise discrimination of dose levels, and may sometimes be useful for monitoring differences in local dose distributions or area monitoring of radiation damage probabilities around particle accelerators or large radionuclide sources....

  10. Automatic Detection of Childhood Absence Epilepsy Seizures: Toward a Monitoring Device

    DEFF Research Database (Denmark)

    Duun-Henriksen, Jonas; Madsen, Rasmus E.; Remvig, Line S.

    2012-01-01

    Automatic detections of paroxysms in patients with childhood absence epilepsy have been neglected for several years. We acquire reliable detections using only a single-channel brainwave monitor, allowing for unobtrusive monitoring of antiepileptic drug effects. Ultimately we seek to obtain optimal...... long-term prognoses, balancing antiepileptic effects and side effects. The electroencephalographic appearance of paroxysms in childhood absence epilepsy is fairly homogeneous, making it feasible to develop patient-independent automatic detection. We implemented a state-of-the-art algorithm...

  11. Calibration and study of the measurement capabilities of real-time gamma spectrometry equipment, developed for the renewal of the network of automatic stations for environmental radiological surveillance of the Generalitat de Catalunya

    International Nuclear Information System (INIS)

    Casanovas, R.; Prieto, E.; Salvado, M.

    2013-01-01

    The renewal of the automatic environmental radiation surveillance network of the Gereralitat of Catalunya has been carried out through the development and implementation of gamma-spectrometry-based equipment. The monitors use scintillation cristals, either NaI(Tl) or LaBr 3 (Ce) and currently, there are 3 types of equipment: water radioactivity monitors, aerosols on a particulate filter monitors and direct measurement monitors. In this paper, we expose the basic features of its operation, the details of their calibration and the minimum detectable activity concentrations for some isotopes

  12. Automatic ingestion monitor: a novel wearable device for monitoring of ingestive behavior.

    Science.gov (United States)

    Fontana, Juan M; Farooq, Muhammad; Sazonov, Edward

    2014-06-01

    Objective monitoring of food intake and ingestive behavior in a free-living environment remains an open problem that has significant implications in study and treatment of obesity and eating disorders. In this paper, a novel wearable sensor system (automatic ingestion monitor, AIM) is presented for objective monitoring of ingestive behavior in free living. The proposed device integrates three sensor modalities that wirelessly interface to a smartphone: a jaw motion sensor, a hand gesture sensor, and an accelerometer. A novel sensor fusion and pattern recognition method was developed for subject-independent food intake recognition. The device and the methodology were validated with data collected from 12 subjects wearing AIM during the course of 24 h in which both the daily activities and the food intake of the subjects were not restricted in any way. Results showed that the system was able to detect food intake with an average accuracy of 89.8%, which suggests that AIM can potentially be used as an instrument to monitor ingestive behavior in free-living individuals.

  13. Influence of the temperature in the measurement of the gamma automatic probe Gamma Tracer; Influencia de la temperatura en la medicion de la sonda gamma automatica Gamma Tracer

    Energy Technology Data Exchange (ETDEWEB)

    Caveda R, C.A.; Dominguez L, O.; Alonso A, D. [CPHR, Calle 20 No. 4113 e/41 y 47, Playa, C.P. 11300, A.P. 6195, C.P. 10600 La Habana (Cuba); Montalvan E, A.; Fabelo B, O. [CIAC, Ave. Finlay Km 2 1/2, Rpto. Puerto Principe, Camaguey 70800 (Cuba)]. e-mail: caveda@cphr.edu.cu

    2006-07-01

    In the following work an analysis of the existent relationship among the measurement of the absorbed dose rate in air due to the environmental gamma radiation and the temperature, magnitudes measured to intervals of 10 minutes by the gamma probe Gamma Tracer located in the post of occident of the National Net of Environmental Radiological Surveillance (RNVRA), in the Center of Protection and Hygiene of the Radiations (CPHR) is made. For it its were analyzed near 100,000 measurements corresponding to the period 2004-2005. For a better processing and interpretation of the data, these were analyzed with one frequency time zone and monthly using the Gamma Red software to which was necessary to add it some options. Finally it was submitted the probe to a heating process inside a stove. The results of the carried out experiments confirmed that the absorbed dose rate in air due to the environmental gamma radiation depends potentially of the probe temperature in the range of environmental temperature to which is subjected daily the same one. (Author)

  14. Prompt-gamma detection towards absorbed energy monitoring during hadrontherapy

    Energy Technology Data Exchange (ETDEWEB)

    Krimmer, J.; Balleyguier, L.; Dauvergne, D.; Mathez, H.; Pinto, M.; Testa, E.; Zoccarato, Y. [Institut de Physique Nucleaire de Lyon, Universite de Lyon, Universite de Lyon 1, IN2P3/CNRS, UMR 5822, F-69622 Villeurbanne cedex (France); Krimmer, J.; Freud, N.; L' etang, J.M. [Universite de Lyon, CREATIS, CNRS UMR 5220, Inserm U1044, INSA - Lyon, Universite Lyon 1, Centre Leon Berard (France); Herault, J.; Amblard, R.; Angellier, G. [Centre Antoine Lacassagne, Cyclotron Biomedical, 227 Avenue de la Lanterne, 06200 Nice (France)

    2015-07-01

    Hadrontherapy is an emerging technique which exploits the fact that a large quantity of the energy of the incident particles is deposited at the end of their flight path. This allows a conformation of the applied dose to the tumor volume and a simultaneous sparing of surrounding healthy tissue. A real-time control of the ion range during the treatment is possible via the detection of prompt secondary radiation (gamma rays or charged particles). Besides a monitoring of the ion range, the knowledge of the total energy absorbed inside the patient is also of importance for an improvement of the treatment quality. It has been shown that the ambient dose in a treatment room is correlated to the monitoring units, i.e. the number of protons of the beam delivery system. The present study consists in applying time-of-flight (TOF) information to identify prompt gamma-rays generated by interactions inside the patient which provides a direct information on the energy imparted. Results from test measurements will be given, which show that events generated in the nozzle and the target phantom can be discriminated. Furthermore, a standalone detection system is being developed which will be read out by a standard PC. The status of the developments for the corresponding electronics will be presented. (authors)

  15. Automatic data acquisition system of environmental radiation monitor with a personal computer

    International Nuclear Information System (INIS)

    Ohkubo, Tohru; Nakamura, Takashi.

    1984-05-01

    The automatic data acquisition system of environmental radiation monitor was developed in a low price by using a PET personal computer. The count pulses from eight monitors settled at four site boundaries were transmitted to a radiation control room by a signal transmission device and analyzed by the computer via 12 channel scaler and PET-CAMAC Interface for graphic display and printing. (author)

  16. Design of automatic control and measurement software for radioactive aerosol continuity monitor

    International Nuclear Information System (INIS)

    Mao Yong; Li Aiwu

    1997-01-01

    The radioactive aerosol continuity measurement is very important for the development of nuclear industry, and it is the major method to measure and find out the leakage of radioactive material. Radioactive aerosol continuity monitor is the advanced method for the radioactive aerosol continuity measurement. With the development of nuclear industry and nuclear power station, it is necessary to design and automatic continuity measurement device. Because of this reason, the authors developed the first unit of radioactive aerosol continuity monitor and adopted the ministry appraisal. The design idea and method of automatic control and measurement for radioactive aerosol continuity monitor are discussed

  17. A fully automatic approach for multimodal PET and MR image segmentation in gamma knife treatment planning.

    Science.gov (United States)

    Rundo, Leonardo; Stefano, Alessandro; Militello, Carmelo; Russo, Giorgio; Sabini, Maria Gabriella; D'Arrigo, Corrado; Marletta, Francesco; Ippolito, Massimo; Mauri, Giancarlo; Vitabile, Salvatore; Gilardi, Maria Carla

    2017-06-01

    Nowadays, clinical practice in Gamma Knife treatments is generally based on MRI anatomical information alone. However, the joint use of MRI and PET images can be useful for considering both anatomical and metabolic information about the lesion to be treated. In this paper we present a co-segmentation method to integrate the segmented Biological Target Volume (BTV), using [ 11 C]-Methionine-PET (MET-PET) images, and the segmented Gross Target Volume (GTV), on the respective co-registered MR images. The resulting volume gives enhanced brain tumor information to be used in stereotactic neuro-radiosurgery treatment planning. GTV often does not match entirely with BTV, which provides metabolic information about brain lesions. For this reason, PET imaging is valuable and it could be used to provide complementary information useful for treatment planning. In this way, BTV can be used to modify GTV, enhancing Clinical Target Volume (CTV) delineation. A novel fully automatic multimodal PET/MRI segmentation method for Leksell Gamma Knife ® treatments is proposed. This approach improves and combines two computer-assisted and operator-independent single modality methods, previously developed and validated, to segment BTV and GTV from PET and MR images, respectively. In addition, the GTV is utilized to combine the superior contrast of PET images with the higher spatial resolution of MRI, obtaining a new BTV, called BTV MRI . A total of 19 brain metastatic tumors, undergone stereotactic neuro-radiosurgery, were retrospectively analyzed. A framework for the evaluation of multimodal PET/MRI segmentation is also presented. Overlap-based and spatial distance-based metrics were considered to quantify similarity concerning PET and MRI segmentation approaches. Statistics was also included to measure correlation among the different segmentation processes. Since it is not possible to define a gold-standard CTV according to both MRI and PET images without treatment response assessment

  18. Usage of aids monitoring in automatic braking systems of modern cars

    Directory of Open Access Journals (Sweden)

    Dembitskyi V.

    2016-08-01

    Full Text Available Increased safety can be carried out at the expense the installation on vehicles of automatic braking systems, that monitor the traffic situation and the actions of the driver. In this paper considered the advantages and disadvantages of automatic braking systems, were analyzed modern tracking tools that are used in automatic braking systems. Based on the statistical data on accidents, are set the main dangers, that the automatic braking system will be reduced. In order to ensure the accuracy of information conducted research for determination of optimal combination of different sensors that provide an adequate perception of road conditions. The tracking system should be equipped with a combination of sensors, which in the case of detection of an obstacle or dangers of signal is transmitted to the information processing system and decision making. Information from the monitoring system should include data for the identification of the object, its condition, the speed.

  19. Statistical data processing with automatic system for environmental radiation monitoring

    International Nuclear Information System (INIS)

    Zarkh, V.G.; Ostroglyadov, S.V.

    1986-01-01

    Practice of statistical data processing for radiation monitoring is exemplified, and some results obtained are presented. Experience in practical application of mathematical statistics methods for radiation monitoring data processing allowed to develop a concrete algorithm of statistical processing realized in M-6000 minicomputer. The suggested algorithm by its content is divided into 3 parts: parametrical data processing and hypotheses test, pair and multiple correlation analysis. Statistical processing programms are in a dialogue operation. The above algorithm was used to process observed data over radioactive waste disposal control region. Results of surface waters monitoring processing are presented

  20. Monitoring of fission products through on-line gamma spectrometry

    International Nuclear Information System (INIS)

    Montagnon, F.; Warlop, R.

    1989-01-01

    Under normal operating conditions, the monitoring of the possible deterioration of the pressurized water reactor core fuel rods is achieved through analysis of the radioactive fission products carried by the primary system. For acquiring results of spectrometric analyses in real time, and avoiding risks of errors linked to manual operations, CEA/DMG and EDF/SEPTEN have jointly developed an entirely automatic system. This system allows measuring permanently the primary system activity of two coupled units, with no human operation nor any handling of active coolant specimens. The PIGAL facility has been set up in the nuclear auxiliary building, common to the two units, and it is used on a demonstration basis for units 2 and 3 of the BUGEY site. This device has been patented

  1. Automatic control and monitoring of the MIT fission converter beam

    International Nuclear Information System (INIS)

    Wilson, B.A.; Riley, K.J.; Harling, O.K.

    2000-01-01

    An automated control and monitoring system for the new MIT high intensity epithermal neutron irradiation facility has been designed and constructed. The neutron beam is monitored with fission counters located at the periphery of the beam near the patient position. Control of the beam is accomplished with redundant Programmable Logic Controllers (PLCs). These industrial controllers open and close the three shutters of the Fission Converter Beam. The control system uses a series of robust components to assure that the prescribed fluence is delivered. This paper discusses the design and implementation of this system. (author)

  2. The Fermi Gamma-ray Burst Monitor (GBM) Terrestrial Gamma-ray Flash (TGF) Catalog

    Science.gov (United States)

    Briggs, M. S.; Roberts, O.; Fitzpatrick, G.; Stanbro, M.; Cramer, E.; Mailyan, B. G.; McBreen, S.; Connaughton, V.; Grove, J. E.; Chekhtman, A.; Holzworth, R.

    2017-12-01

    The revised Second Fermi GBM TGF catalog includes data on 4144 TGFs detected by the Fermi Gamma-ray Burst Monitor through 2016 July 31. The catalog includes 686 bright TGFs there were detected in orbit and 4135 TGFs that were discovered by ground analysis of GBM data (the two samples overlap). Thirty of the events may have been detected as electrons and positrons rather than gamma-rays: Terrestrial Electron Beams (TEBs). We also provide results from correlating the GBM TGFs with VLF radio detections of the World Wide Lightning Location Network (WWLLN). TGFs with WWLLN associations have their localization uncertainties improved from 800 to 10 km, making it possible to identify specific thunderstorms responsible for the TGFs and opening up new types of scientific investigations. There are 1544 TGFs with WWLLN associations; maps are provided for these and the other TGFs of the catalog. The data tables of the catalog are available for use by the scientific community at the Fermi Science Support Center, at https://fermi.gsfc.nasa.gov/ssc/data/access/gbm/tgf/.

  3. LOCALIZATION OF GAMMA-RAY BURSTS USING THE FERMI GAMMA-RAY BURST MONITOR

    Energy Technology Data Exchange (ETDEWEB)

    Connaughton, V.; Briggs, M. S.; Burgess, J. M. [CSPAR and Physics Department, University of Alabama in Huntsville, 320 Sparkman Drive, Huntsville, AL 35899 (United States); Goldstein, A.; Wilson-Hodge, C. A. [Astrophysics Office, ZP12, NASA/Marshall Space Flight Center, Huntsville, AL 35812 (United States); Meegan, C. A.; Jenke, P.; Pelassa, V.; Xiong, S.; Bhat, P. N. [CSPAR, University of Alabama in Huntsville, 320 Sparkman Drive, Huntsville, AL 35899 (United States); Paciesas, W. S. [Universities Space Research Association, Huntsville, AL (United States); Preece, R. D. [Department of Space Science, University of Alabama in Huntsville, 320 Sparkman Drive, Huntsville, AL 35899 (United States); Gibby, M. H. [Jacobs Technology, Inc., Huntsville, AL (United States); Greiner, J.; Yu, H.-F. [Max-Planck-Institut für extraterrestrische Physik, Giessenbachstrasse 1, D-85748 Garching (Germany); Gruber, D. [Planetarium Südtirol, Gummer 5, I-39053 Karneid (Italy); Kippen, R. M. [Los Alamos National Laboratory, NM 87545 (United States); Byrne, D.; Fitzpatrick, G.; Foley, S., E-mail: valerie@nasa.gov [School of Physics, University College Dublin, Belfield, Stillorgan Road, Dublin 4 (Ireland); and others

    2015-02-01

    The Fermi Gamma-ray Burst Monitor (GBM) has detected over 1400 gamma-ray bursts (GRBs) since it began science operations in 2008 July. We use a subset of over 300 GRBs localized by instruments such as Swift, the Fermi Large Area Telescope, INTEGRAL, and MAXI, or through triangulations from the InterPlanetary Network, to analyze the accuracy of GBM GRB localizations. We find that the reported statistical uncertainties on GBM localizations, which can be as small as 1°, underestimate the distance of the GBM positions to the true GRB locations and we attribute this to systematic uncertainties. The distribution of systematic uncertainties is well represented (68% confidence level) by a 3.°7 Gaussian with a non-Gaussian tail that contains about 10% of GBM-detected GRBs and extends to approximately 14°. A more complex model suggests that there is a dependence of the systematic uncertainty on the position of the GRB in spacecraft coordinates, with GRBs in the quadrants on the Y axis better localized than those on the X axis.

  4. Automatic high frequency monitoring for improved lake and reservoir management

    Czech Academy of Sciences Publication Activity Database

    Marcé, R.; George, G.; Buscarinu, P.; Deidda, M.; Dunalska, J.; de Eyto, E.; Flaim, G.; Grossart, H. P.; Istvánovics, V.; Lenhardt, M.; Moreno-Ostos, E.; Obrador, B.; Ostrovsky, I.; Pierson, D. C.; Potužák, Jan; Poikane, S.; Rinke, K.; Rodríguez-Mozaz, S.; Staehr, P. A.; Šumberová, Kateřina; Waajen, G.; Weyhenmeyer, G. A.; Weathers, K. C.; Zion, M.; Ibelings, B. W.; Jennings, E.

    2016-01-01

    Roč. 50, č. 20 (2016), s. 10780-10794 ISSN 0013-936X R&D Projects: GA MŠk(CZ) LD14045 Institutional support: RVO:67985939 Keywords : monitoring of water resources * water reservoir management * sensors Subject RIV: EH - Ecology, Behaviour Impact factor: 6.198, year: 2016

  5. Automatic fatigue monitoring based on real loads. Live demonstration

    International Nuclear Information System (INIS)

    Bergholz, Steffen; Rudolph, Juergen; Bruckmueller, Florian; Heinz, Benedikt; Jouan, Benoit

    2012-01-01

    The fatigue assessment of power plant components based on local fatigue monitoring approaches is an essential part of the integrity concept and modern lifetime management. An integral approach like the AREVA Fatigue Concept (AFC) basically consists of two essential modules: realistic determination of occurring operational thermal loads by means of a high end fatigue monitoring system and related highly qualified fatigue assessment methods and tools. The fatigue monitoring system delivers continuously realistic load data at the fatigue relevant locations. Consequently, realistic operational load sequences are available as input data for all ensuing fatigue analyses. This way, realistic load data are available and qualified fatigue usage factors can be determined. The mode of operation of the fatigue monitoring system will be explained in the framework of a live demonstration by means of the FAMOSi (i = integrated) demonstration wall. The workflow starts with the continuous online measurement of outer wall temperatures transients on a pipe. Visualization is implemented within the FAMOSi viewer software. In a second step, inner wall temperatures are directly calculated. In a third step, the resulting linearly elastic stress history will be calculated as the basis for subsequent code conforming fatigue assessment. Subsequently, the related advanced fatigue assessment methods of the three staged AFC-approach are addressed.

  6. The D0 online monitoring and automatic DAQ recovery

    International Nuclear Information System (INIS)

    Haas, A.

    2004-01-01

    The DZERO experiment, located at the Fermi National Accelerator Laboratory, has recently started the Run 2 physics program. The detector upgrade included a new Data Acquisition/Level 3 Trigger system. Part of the design for the DAQ/Trigger system was a new monitoring infrastructure. The monitoring was designed to satisfy real-time requirements with 1-second resolution as well as nonreal-time data. It was also designed to handle a large number of displays without putting undue load on the sources of monitoring information. The resulting protocol is based on XML, is easily extensible, and has spawned a large number of displays, clients, and other applications. It is also one of the few sources of detector performance available outside the Online System's security wall. A tool, based on this system, which provides for auto-recovery of DAQ errors, has been designed. This talk will include a description of the DZERO DAQ/Online monitor server, based on the ACE framework, the protocol, the auto-recovery tool, and several of the unique displays which include an ORACLE-based archiver and numerous GUIs

  7. CERPI and CEREL, two computer codes for the automatic identification and determination of gamma emitters in thermal-neutron-activated samples

    International Nuclear Information System (INIS)

    Giannini, M.; Oliva, P.R.; Ramorino, M.C.

    1979-01-01

    A computer code that automatically analyzes gamma-ray spectra obtained with Ge(Li) detectors is described. The program contains such features as automatic peak location and fitting, determination of peak energies and intensities, nuclide identification, and calculation of masses and errors. Finally, the results obtained with this computer code for a lunar sample are reported and briefly discussed

  8. Automatic solar image motion measurements. [electronic disk flux monitoring

    Science.gov (United States)

    Colgate, S. A.; Moore, E. P.

    1975-01-01

    The solar seeing image motion has been monitored electronically and absolutely with a 25 cm telescope at three sites along the ridge at the southern end of the Magdalena Mountains west of Socorro, New Mexico. The uncorrelated component of the variations of the optical flux from two points at opposite limbs of the solar disk was continually monitored in 3 frequencies centered at 0.3, 3 and 30 Hz. The frequency band of maximum signal centered at 3 Hz showed the average absolute value of image motion to be somewhat less than 2sec. The observer estimates of combined blurring and image motion were well correlated with electronically measured image motion, but the observer estimates gave a factor 2 larger value.

  9. A portable, automatic SNM monitor for nuclear safeguards: Development, evaluation, and applications

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1993-09-01

    The portable SNM monitor is a lightweight, full-size, automatic monitor, suitable for temporary service (such as demonstrations or for use during maintenance) or as a permanent replacement for hand- held monitors. The authors based the monitor on the TSA Systems, Ltd., modular SNM monitor design and, through evaluation and improvement of the commercial modules, obtained adequate sensitivity in a single- cabinet monitor that is easily portable. Complete monitoring of pedestrians with a single detector cabinet is achieved by requiring the pedestrian to stand in front of the detectors and turn around through 360 deg while being observed by a security inspector. The monitor is available commercially as the TSA Systems Model PMD-701, and it is beginning to be used in both temporary and permanent applications

  10. Automatic Energy Control And Monitoring System For Building

    Directory of Open Access Journals (Sweden)

    Hnin Nu Thaung

    2015-08-01

    Full Text Available The use of smart home technology in the home or building offers significant potential for energy savings. In this paper an energy management system based on wireless sensor networks. The proposed system is composed of two main components a wireless sensor network and monitoring terminal. Wireless sensors are used for sensing and transmitting electricity data and remote monitoring and control of appliances are provided to users through computer. The system enables users to save energy by monitoring and controlling appliances through terminal. This paper gives an overview of sensor technology and wireless networks in the development of an intelligent energy management system for buildings. This technology has ample potential to change the way live and work. ZigBee is used as a communication medium in building intelligent energy management system in this paper. From the prototype setup it is shown that ZigBee is a suitable technology to be adopted as the communication infrastructure in energy management system for buildings .The proposed system can be installed and maintained in residential environments with ease.

  11. Use of Automatic Interaction Detector in Monitoring Faculty Salaries. AIR 1983 Annual Forum Paper.

    Science.gov (United States)

    Cohen, Margaret E.

    A university's use of the Automatic Interaction Detector (AID) to monitor faculty salary data is described. The first step consists of examining a tree diagram and summary table produced by AID. The tree is used to identify the characteristics of faculty at different salary levels. The table is used to determine the explanatory power of the…

  12. Monitoring the Performance of the Pedestrian Transfer Function of Train Stations Using Automatic Fare Collection Data

    NARCIS (Netherlands)

    Van den Heuvel, J.P.A.; Hoogenraad, J.H.

    2014-01-01

    Over the last years all train stations in The Netherlands have been equipped with automatic fare collection gates and/or validators. All public transport passengers use a smart card to pay their fare. In this paper we present a monitor for the performance of the pedestrian function of train stations

  13. Development and calibration automatic equipment's measuring in real time of the environmental radioactivity by gamma spectrometry

    International Nuclear Information System (INIS)

    Casanovas, R.; Morant, J. J.; Salvado, M.

    2013-01-01

    In this paper, we describe the general aspects of the implementation of gamma spectrometry in water, as well as the development of two measuring devices based on this technique: aerosol monitor (RARM-F) and a monitor direct measurement (RARMD2) , both patent applications. Furthermore, they described in detail the aspects of calibration of equipment, which has been made by combining experimental measurements with Monte Carlo simulations. (Author)

  14. Automatic measurement for monitoring crack growth with electric potential technique

    International Nuclear Information System (INIS)

    Nakajima, Nobuya; Kikuchi, Masaaki; Shima, Seishi

    1981-10-01

    In the study of fracture mechanics, it is one of the most important problems to monitor the crack growth phenomena. Recently, many experimental methods have been developed. In this report, the Direct Current (DC) potential method is employed for measuring the crack growth length in the pressuried high temperature water. The objective of the current investigation is to develop an experimental method to quantify the sensitivity of this method in the air environment using the Compact Tension (CT) specimen. The main results obtained are as follows: 1) It is ignored that the electrical potential changes with plastic deformation at the crack tip of the specimen. 2) Using the Reversible Direct Current (RDC) Method, the measurement system gives no effect on the electrical stability for a long time. 3) For the fatigue and statical crack growth length, good relation is observed between the crack length-to-specimen width ratio (a/W) and potential ratio (Va/Vo). (author)

  15. The automatic radiation monitor distributed System SRM-256C

    International Nuclear Information System (INIS)

    Stetsenko, G.N.; Rastsvetalov, Y.N.; Yanovich, A.A.

    1996-01-01

    The Controlled and Supervised Areas (CSA) of UNK proton accelerator built in Protvino (IHEP, Russia), borrows the significant area (more than 15 sq.km). Submitted in work results of accounts show, that by major factors, influencing to a radioecological conditions in region at the expense of work UNK are: 1) the output of pulsing radiation on day-time surface; 2) the radionuclides receipts with drinking water; 3) the pollution of radioactive air from system of ventilation. At normal mode of UNK operation the equivalent dose rates on daytime surface of pulsing radiation will changes in limits from 0.5 mcSv/hours near overmines buildings up to 0.1 mcSv / hour on the CSA border. The average equivalent dose rates per year due to internal irradiation at use (intakes) of drinking water will not exceed 5 - 50 mcSv/years. The Maximum equivalent dose rates on day-time surface, caused by pollution of radioactive air does not exceed 0.01... 0.03 mcSv/hour in limits of CSA, and the average equivalent dose per year caused by internal irradiation does not exceed 0.05 mcSv/years. At emergency-free operation the maximum degree of the UNK influence in limits of CSA is estimated in terms of average equivalent dose per year at levels, not exceeding 0.05... 0.10 mSv/year. For maintenance of integral environmental monitoring of total external radiation levels in limits of CSA network of passive monitor stations will be developed

  16. Monitoring system for isolated limb perfusion based on a portable gamma camera

    International Nuclear Information System (INIS)

    Orero, A.; Muxi, A.; Rubi, S.; Duch, J.; Vidal-Sicart, S.; Pons, F.; Roe, N.; Rull, R.; Pavon, N.; Pavia, J.

    2009-01-01

    Background: The treatment of malignant melanoma or sarcomas on a limb using extremity perfusion with tumour necrosis factor (TNF-α) and melphalan can result in a high degree of systemic toxicity if there is any leakage from the isolated blood territory of the limb into the systemic vascular territory. Leakage is currently controlled by using radiotracers and heavy external probes in a procedure that requires continuous manual calculations. The aim of this work was to develop a light, easily transportable system to monitor limb perfusion leakage by controlling systemic blood pool radioactivity with a portable gamma camera adapted for intraoperative use as an external probe, and to initiate its application in the treatment of MM patients. Methods: A special collimator was built for maximal sensitivity. Software for acquisition and data processing in real time was developed. After testing the adequacy of the system, it was used to monitor limb perfusion leakage in 16 patients with malignant melanoma to be treated with perfusion of TNF-α and melphalan. Results: The field of view of the detector system was 13.8 cm, which is appropriate for the monitoring, since the area to be controlled was the precordial zone. The sensitivity of the system was 257 cps/MBq. When the percentage of leakage reaches 10% the associated absolute error is ±1%. After a mean follow-up period of 12 months, no patients have shown any significant or lasting side-effects. Partial or complete remission of lesions was seen in 9 out of 16 patients (56%) after HILP with TNF-α and melphalan. Conclusion: The detector system together with specially developed software provides a suitable automatic continuous monitoring system of any leakage that may occur during limb perfusion. This technique has been successfully implemented in patients for whom perfusion with TNF-α and melphalan has been indicated. (orig.)

  17. Monitoring system for isolated limb perfusion based on a portable gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Orero, A.; Muxi, A.; Rubi, S.; Duch, J. [Servei de Medicina Nuclear, Hospital Clinic, Barcelona (Spain); Vidal-Sicart, S.; Pons, F. [Servei de Medicina Nuclear, Hospital Clinic, Barcelona (Spain); Inst. d' Investigacions Biomediques August Pi i Sunyer (IDIBAPS), Barcelona (Spain); Red Tematica de Investigacion Cooperativa en Cancer (RTICC), Barcelona (Spain); Roe, N. [Servei de Medicina Nuclear, Hospital Clinic, Barcelona (Spain); CIBER de Bioingenieria, Biomateriales y Nanomedicina (CIBER-BBN), Barcelona (Spain); Rull, R. [Servei de Cirurgia, Hospital Clinic, Barcelona (Spain); Pavon, N. [Inst. de Fisica Corpuscular, CSIC - UV, Valencia (Spain); Pavia, J. [Servei de Medicina Nuclear, Hospital Clinic, Barcelona (Spain); Inst. d' Investigacions Biomediques August Pi i Sunyer (IDIBAPS), Barcelona (Spain); CIBER de Bioingenieria, Biomateriales y Nanomedicina (CIBER-BBN), Barcelona (Spain)

    2009-07-01

    Background: The treatment of malignant melanoma or sarcomas on a limb using extremity perfusion with tumour necrosis factor (TNF-{alpha}) and melphalan can result in a high degree of systemic toxicity if there is any leakage from the isolated blood territory of the limb into the systemic vascular territory. Leakage is currently controlled by using radiotracers and heavy external probes in a procedure that requires continuous manual calculations. The aim of this work was to develop a light, easily transportable system to monitor limb perfusion leakage by controlling systemic blood pool radioactivity with a portable gamma camera adapted for intraoperative use as an external probe, and to initiate its application in the treatment of MM patients. Methods: A special collimator was built for maximal sensitivity. Software for acquisition and data processing in real time was developed. After testing the adequacy of the system, it was used to monitor limb perfusion leakage in 16 patients with malignant melanoma to be treated with perfusion of TNF-{alpha} and melphalan. Results: The field of view of the detector system was 13.8 cm, which is appropriate for the monitoring, since the area to be controlled was the precordial zone. The sensitivity of the system was 257 cps/MBq. When the percentage of leakage reaches 10% the associated absolute error is {+-}1%. After a mean follow-up period of 12 months, no patients have shown any significant or lasting side-effects. Partial or complete remission of lesions was seen in 9 out of 16 patients (56%) after HILP with TNF-{alpha} and melphalan. Conclusion: The detector system together with specially developed software provides a suitable automatic continuous monitoring system of any leakage that may occur during limb perfusion. This technique has been successfully implemented in patients for whom perfusion with TNF-{alpha} and melphalan has been indicated. (orig.)

  18. Automatic radiation dose monitoring for CT of trauma patients with different protocols: feasibility and accuracy

    International Nuclear Information System (INIS)

    Higashigaito, K.; Becker, A.S.; Sprengel, K.; Simmen, H.-P.; Wanner, G.; Alkadhi, H.

    2016-01-01

    Aim: To demonstrate the feasibility and accuracy of automatic radiation dose monitoring software for computed tomography (CT) of trauma patients in a clinical setting over time, and to evaluate the potential of radiation dose reduction using iterative reconstruction (IR). Materials and methods: In a time period of 18 months, data from 378 consecutive thoraco-abdominal CT examinations of trauma patients were extracted using automatic radiation dose monitoring software, and patients were split into three cohorts: cohort 1, 64-section CT with filtered back projection, 200 mAs tube current–time product; cohort 2, 128-section CT with IR and identical imaging protocol; cohort 3, 128-section CT with IR, 150 mAs tube current–time product. Radiation dose parameters from the software were compared with the individual patient protocols. Image noise was measured and image quality was semi-quantitatively determined. Results: Automatic extraction of radiation dose metrics was feasible and accurate in all (100%) patients. All CT examinations were of diagnostic quality. There were no differences between cohorts 1 and 2 regarding volume CT dose index (CTDI_v_o_l; p=0.62), dose–length product (DLP), and effective dose (ED, both p=0.95), while noise was significantly lower (chest and abdomen, both −38%, p<0.017). Compared to cohort 1, CTDI_v_o_l, DLP, and ED in cohort 3 were significantly lower (all −25%, p<0.017), similar to the noise in the chest (–32%) and abdomen (–27%, both p<0.017). Compared to cohort 2, CTDI_v_o_l (–28%), DLP, and ED (both –26%) in cohort 3 was significantly lower (all, p<0.017), while noise in the chest (+9%) and abdomen (+18%) was significantly higher (all, p<0.017). Conclusion: Automatic radiation dose monitoring software is feasible and accurate, and can be implemented in a clinical setting for evaluating the effects of lowering radiation doses of CT protocols over time. - Highlights: • Automatic dose monitoring software can be

  19. Automatic system for monitoring fish passage at dams

    Science.gov (United States)

    Castignolles, Nathalie; Cattoen, Michel; Larinier, M.

    1994-09-01

    Devices called fishways or fish passes are constructed in rivers to help migratory fish get over obstacles (dams). There counting windows are used to monitor fish passage by video-based counting. Our goal is to design and construct a vision system to automate this process. Images are taken by a video camera fitted with an electronic shutter in a backlit fishway. They are stored on optical disks in real time but are processed in delayed time. Faced with high volumes of data, a compression is necessary and an electronic board has been designed to accomplish it in real time. The coding method used is based on a run description of binarized images. Then, a tracking process is implemented on a micro-computer to count the fish crossing the pass. It includes fish recognition, which is based on a Bayesian classification process. In order to reduce processing times, recognition operations (labelling, parameter extraction) are accomplished on coded images. Classification results are satisfactory and are improved by the temporal redundancy generated by the tracking process. Image processing time permits the user, on average, to process images faster than they have been stored. Thus there is no data accumulation. At the end of the processing it is possible to edit a result file, to choose a fish, view its crossing images and change its species if wrong.

  20. Monitoring gamma radioactivity over large land areas using portable equipment

    International Nuclear Information System (INIS)

    Mac Mahon, T.D.; Gray, P.W.; Eer, A.M. D'; Naboulsi, A.H.; Koutsoyannopoulos, C.

    1990-01-01

    The principal objective of this research has been to provide information on cost-effective techniques to detect localized areas of gamma-emitting radionuclides. This objective has been achieved by determining the time required to scan unit area as a function of depth of the gamma source below the site surface, the activity of the gamma source, the energy of the emitted gamma-ray, and the gamma transport properties of the site material. A comparison between survey and sampling techniques is made, and the advantages of using survey techniques to detect localized gamma-ray sources are discussed. A survey technique based on an adaptive moving array detector system is described. A field experiment has been carried out to verify the results of calculations of the sensitivity of the techniques described

  1. Real time gamma monitoring for employees working in an operational underground copper / uranium mine

    International Nuclear Information System (INIS)

    Lawrence, Cameron E.

    2010-01-01

    For many years electronic devices have been available that are compact enough to utilise for personal gamma radiation monitoring. At BHP Billiton's Olympic Dam underground copper / uranium mine two different types of electronic gamma dosimeters are being used to assess and control exposure to gamma rays present in the underground operations. Canberra Dosicards are being used as part of a program that replaced the use of monthly issued Thermoluminescent Dosimeter (TLD) badges with quarterly issue for some work groups. Two types of Polimaster gamma watches have also been introduced to specific work groups to assist with the determination of sites that may require remedial controls for their level of gamma radiation. To date, both programs have been successfully implemented into the radiation monitoring program for the underground operation and have provided dramatic improvements for the control and determination of sources of gamma radiation in the underground environment.

  2. Information processing requirements for on-board monitoring of automatic landing

    Science.gov (United States)

    Sorensen, J. A.; Karmarkar, J. S.

    1977-01-01

    A systematic procedure is presented for determining the information processing requirements for on-board monitoring of automatic landing systems. The monitoring system detects landing anomalies through use of appropriate statistical tests. The time-to-correct aircraft perturbations is determined from covariance analyses using a sequence of suitable aircraft/autoland/pilot models. The covariance results are used to establish landing safety and a fault recovery operating envelope via an event outcome tree. This procedure is demonstrated with examples using the NASA Terminal Configured Vehicle (B-737 aircraft). The procedure can also be used to define decision height, assess monitoring implementation requirements, and evaluate alternate autoland configurations.

  3. Equipment for automatic measurement of gamma activity distribution in a column

    International Nuclear Information System (INIS)

    Kalincak, M.; Machan, V.; Vilcek, S.; Balkovsky, K.

    1978-01-01

    The design of a device for stepwise scanning of gamma activity distributions along chromatographic columns is described. In connection with a single-channel gamma spectrometer and a counting ratemeter with a recorder this device permits the resolution of a number of gamma emitters on the column, the determination of the gamma nuclide content in different chemical forms in the sample by means of column separation methods - Gel Chromatography Columns Scanning Method - and the determination of gamma nuclide distribution along the columns. The device permits the scanning of columns of up to 20 mm in diameter and 700 mm in length and continual scanning over a 450 mm column length with one clamping. With minor adaptations it is possible to scan columns up to 30 mm in diameter. The length of the scanned sections is 5 or 10 mm, the scanning time setting is arbitrary and variable activity levels and radiation energies may be measured. (author)

  4. Study of the contribution of the radon in the measurement with an automatic gamma probe

    International Nuclear Information System (INIS)

    Caveda Ramos, C.A.; Dominguez Levy, O.; Alonso Abad, D.; Montalvan Estrada, A.; Fabelo Bonet, O.

    2008-01-01

    In this work, study about the influence of the radon in the daily measurements of the dose rate absorbed in air due to the environmental gamma radiation is achieved. This magnitude is measured each ten minutes for the Gamma Tracer probe, which is located in the western station of the National Network of Environmental Radiological Surveillance of the Republic of Cuba, this station belongs to the Center of Protection and Hygiene of the Radiations (CPHR). For achieving such study approximately 157 680 measurements of the gamma dose rate corresponding the period 2004-2006 were analyzed. The gamma probe used has two independent counter channels which are both complemented with a Geiger-Muller detector; also it can only detect gamma radiation and perform measurements of the gamma dose rate between 8.7 n Gy/h and 8.7 mGy/h. This probe is located at the height of 3.5 m and is exposed to the sun rays directly. For improving the interpretation of the data, the average of all the values of gamma dose rate was calculated, for each hour of the 365 days of the year. The values were also monthly averaged out. The data were processed by employing the software Gamma Red which was improved by adding some options. A comparison between the results obtained and the annual radon variation internationally published was made. With the present study, it was proved that the main contribution to the daily measurements of the dose rate absorbed in the air due to environmental gamma radiation, on stable weather conditions, is associated with the radon daughters which emit gamma radiation. (author)

  5. Threshold self-powered gamma detector for use as a nuclear reactor power monitor

    International Nuclear Information System (INIS)

    LeVert, F.E.

    1977-01-01

    A study of a threshold self-powered gamma detector for use as a nuclear reactor power monitor was conducted. Measurements were performed to ascertain whether certain detector material arrangements could be used to obtain significant discrimination against low energy gammas. Results indicating agreement between detector response and reactor power output are presented. Evidence of rejection of low energy gammas by the detector is presented. The simplicity of construction and ruggedness of the detector are also discussed

  6. Development and Application of Devices for Remote Monitoring of Gamma-Ray Contamination at RECOM Ltd

    International Nuclear Information System (INIS)

    Ivanov, O.P.; Stepanov, V.E.; Chesnokov, A.V.; Sudarkin, A.N.; Urutskoev, L.I.

    1999-01-01

    Devices for remote monitoring of gamma-ray contamination develop at RECOM Ltd. are described and typical examples of their application are show. The following devices are discussed: spectrum-sensitive collimated devices for mapping of radioactivity on contaminated surfaces- scanning collimated Gamma Locator, device for field Cs-137 contamination mapping-CORAD; devices for gamma-ray imaging computer-controlled High-Energy Radiation Visualizer (HERV) and Coded Mask Imager

  7. Development of the computer code to monitor gamma radiation in the nuclear facility environment

    International Nuclear Information System (INIS)

    Akhmad, Y. R.; Pudjiyanto, M.S.

    1998-01-01

    Computer codes for gamma radiation monitoring in the vicinity of nuclear facility which have been developed could be introduced to the commercial potable gamma analyzer. The crucial stage of the first year activity was succeeded ; that is the codes have been tested to transfer data file (pulse high distribution) from Micro NOMAD gamma spectrometer (ORTEC product) and the convert them into dosimetry and physics quantities. Those computer codes are called as GABATAN (Gamma Analyzer of Batan) and NAGABAT (Natural Gamma Analyzer of Batan). GABATAN code can isable to used at various nuclear facilities for analyzing gamma field up to 9 MeV, while NAGABAT could be used for analyzing the contribution of natural gamma rays to the exposure rate in the certain location

  8. Gamma-ray monitor for plutonium uniformity in fuel tubes

    International Nuclear Information System (INIS)

    Winn, W.G.

    1981-01-01

    Plutonium fuel tubes must be examined for abnormal PuO 2 densities. A fuel-gamma densitometer (FGD) was developed to measure the PuO 2 content within 3.2-mm-diameter areas. The FGD measurement of hot spot densities is an extension of the usual gamma-scanner application of verifying fuel uniformity within a few percent

  9. Automatic storage of single gamma spectra on magnetic tape. Programs Longo, Dire

    International Nuclear Information System (INIS)

    Los Arcos Merino, J.M.

    1978-01-01

    The program Longo provides the block size and the black number in a binary file on magnetic tape. It has been applied to analyse the structure of the nine-track magnetic tapes storing single or coincidence gamma spectra files, recorded in octet form by a Multi-8 minicomputer in the Nuclear Spectrometry Laboratory of J.E.N. Then the program Dire has been written to transform the single gamma spectra into a new Fastrand disk file, storing the information in 36 bit words. A copy of this file is obtained on magnetic tape and the single gamma spectra are then availables by standard Fortran V reading sentences. (author)

  10. Automatic storing of single gamma spectra on magnetic tape. Programs LONGO, DIRE

    International Nuclear Information System (INIS)

    Los Arcos Merino, J. M.

    1978-01-01

    The program LONGO provides the block size and the block number in a binary file on magnetic tape. It has been applied to analyse the structure of the nine-track magnetic tapes storing single or coincidence gamma spectra files, recorded in octet form by a MULTI-8 minicomputer in the Nuclear Spectrometry Laboratory of J.E.N. Then the program DIRE has been written to transform the single gamma spectra into a new FASTRAND disk file, storing the information in-36 bit words. A copy of this file is obtained on magnetic tape and the single gamma spectra are then available by standard FORTRAN V reading sentences. (Author) 3 refs

  11. Design of an automatic production monitoring system on job shop manufacturing

    Science.gov (United States)

    Prasetyo, Hoedi; Sugiarto, Yohanes; Rosyidi, Cucuk Nur

    2018-02-01

    Every production process requires monitoring system, so the desired efficiency and productivity can be monitored at any time. This system is also needed in the job shop type of manufacturing which is mainly influenced by the manufacturing lead time. Processing time is one of the factors that affect the manufacturing lead time. In a conventional company, the recording of processing time is done manually by the operator on a sheet of paper. This method is prone to errors. This paper aims to overcome this problem by creating a system which is able to record and monitor the processing time automatically. The solution is realized by utilizing electric current sensor, barcode, RFID, wireless network and windows-based application. An automatic monitoring device is attached to the production machine. It is equipped with a touch screen-LCD so that the operator can use it easily. Operator identity is recorded through RFID which is embedded in his ID card. The workpiece data are collected from the database by scanning the barcode listed on its monitoring sheet. A sensor is mounted on the machine to measure the actual machining time. The system's outputs are actual processing time and machine's capacity information. This system is connected wirelessly to a workshop planning application belongs to the firm. Test results indicated that all functions of the system can run properly. This system successfully enables supervisors, PPIC or higher level management staffs to monitor the processing time quickly with a better accuracy.

  12. Automatic Welding System of Aluminum Pipe by Monitoring Backside Image of Molten Pool Using Vision Sensor

    Science.gov (United States)

    Baskoro, Ario Sunar; Kabutomori, Masashi; Suga, Yasuo

    An automatic welding system using Tungsten Inert Gas (TIG) welding with vision sensor for welding of aluminum pipe was constructed. This research studies the intelligent welding process of aluminum alloy pipe 6063S-T5 in fixed position and moving welding torch with the AC welding machine. The monitoring system consists of a vision sensor using a charge-coupled device (CCD) camera to monitor backside image of molten pool. The captured image was processed to recognize the edge of molten pool by image processing algorithm. Neural network model for welding speed control were constructed to perform the process automatically. From the experimental results it shows the effectiveness of the control system confirmed by good detection of molten pool and sound weld of experimental result.

  13. Borehole Calibration Facilities to Support Gamma Logging for Hanford Subsurface Investigation and Contaminant Monitoring - 13516

    International Nuclear Information System (INIS)

    McCain, R.G.; Henwood, P.D.; Pope, A.D.; Pearson, A.W.

    2013-01-01

    Repeated gamma logging in cased holes represents a cost-effective means to monitor gamma-emitting contamination in the deep vadose zone over time. Careful calibration and standardization of gamma log results are required to track changes and to compare results over time from different detectors and logging systems. This paper provides a summary description of Hanford facilities currently available for calibration of logging equipment. Ideally, all logging organizations conducting borehole gamma measurements at the Hanford Site will take advantage of these facilities to produce standardized and comparable results. (authors)

  14. Borehole Calibration Facilities to Support Gamma Logging for Hanford Subsurface Investigation and Contaminant Monitoring - 13516

    Energy Technology Data Exchange (ETDEWEB)

    McCain, R.G.; Henwood, P.D.; Pope, A.D.; Pearson, A.W. [S M Stoller Corporation, 2439 Robertson Drive, Richland, WA 99354 (United States)

    2013-07-01

    Repeated gamma logging in cased holes represents a cost-effective means to monitor gamma-emitting contamination in the deep vadose zone over time. Careful calibration and standardization of gamma log results are required to track changes and to compare results over time from different detectors and logging systems. This paper provides a summary description of Hanford facilities currently available for calibration of logging equipment. Ideally, all logging organizations conducting borehole gamma measurements at the Hanford Site will take advantage of these facilities to produce standardized and comparable results. (authors)

  15. Analysis on machine tool systems using spindle vibration monitoring for automatic tool changer

    OpenAIRE

    Shang-Liang Chen; Yin-Ting Cheng; Chin-Fa Su

    2015-01-01

    Recently, the intelligent systems of technology have become one of the major items in the development of machine tools. One crucial technology is the machinery status monitoring function, which is required for abnormal warnings and the improvement of cutting efficiency. During processing, the mobility act of the spindle unit determines the most frequent and important part such as automatic tool changer. The vibration detection system includes the development of hardware and software, such as ...

  16. Automatic vibration monitoring system for the diagnostic inspection of the WWER-440 type nuclear power plants

    International Nuclear Information System (INIS)

    Hollo, E.; Siklossy, P.; Toth, Zs.

    1982-01-01

    In the Hungarian Research Institute for Electric Power Industry (VEIKI) an automatic vibration monitoring system for diagnostics and inspection of nuclear power plants of type WWER-440 was developed. The paper summarizes the results of this work and investigates the use of mechanical vibrations and oscillations induced by flow for fault diagnosis. The design of the hardware system, the present software possibilities, the laboratory experiments and the guidelines for future software developments are also described in detail. (A.L.)

  17. Physical principles of neutron-gamma materials monitoring

    Science.gov (United States)

    Pekarskii, G. Sh.

    1986-03-01

    The physical principles of secondary radiation methods in nondestructive testing are discussed. Among the techniques considered are: neutron activation analysis (NAA); the induced-radiation method; and quasialbedo recording of secondary gamma-radiation. Emphasis is given to the neutron-gamma method which consists of exposing test material to a neutron flux and recording the secondary gamma-radiation by means of a spectrometer. The limitations of the method in detecting local inhomogeneous defects (filled pores cracks, and inclusions) in metal layers and multicomponents materials are described, and some advantages of the method over NAA are discussed. Formulas are derived for estimating the optimum density of the gamma-ray flux which is received by the detector.

  18. Automatic setting of the distance between sample and detector in gamma-ray spectroscopy

    International Nuclear Information System (INIS)

    Andeweg, A.H.

    1980-01-01

    An apparatus has been developed that automatically sets the distance from the sample to the detector according to the radioactivity of the sample. The distance-setting unit works in conjuction with an automatic sample changer, and is interconnected with other components so that the counting head automatically moves to the optimum distance for the analysis of a particular sample. The distance, which is indicated digitally in increments of 0,01 mm, can be set between 18 and 995 mm at count rates that can be preset between 1000 and 10 000 counts per second. On being tested, the instrument performed well within the desired range and accuracy. Under routine conditions, the spectra were much more accurate than before, especially when samples of different radioactivity were counted

  19. Automatization of the measurement to the environmental gamma dose rate and of meteorological variables that condition it

    International Nuclear Information System (INIS)

    Dominguez, O.; Alonso, D.; Capote, E.; Ramos, E.O.; Carrazana, J. A.; Prendes, M.; Manzano, J. F.; Tomas, J.; Kalbert, O.; Ledo, L.M.; Guibert, R.; Leyva, J.C.; Montalvan, A.; Fabelo, O.; Cartas, H.

    2004-01-01

    The National Network of Environmental Radiological Surveillance of the Republic of Cuba has strengthened its detection and answer capacity regarding its constant monitoring of the National atmospheric means. 4 type A posts of that network measure the gamma dose rate and the data are being received in real time. The CPHR as head Center receives the information of the remaining posts at a relatively short time, for a series of computer tools, has been developed for that purpose. On the other hand, in the radiological post of our center the wind speed and its direction monitoring have been automated, the information on these meteorological variables is collected in real time

  20. Automation of the monitoring in real time of the absorbed dose rate in air due to the environmental gamma radiation in Cuba

    International Nuclear Information System (INIS)

    Dominguez L, O.; Capote F, E.; Carrazana G, J.A.; Manzano de Armas, J.F.; Alonso A, D.; Prendes A, M.; Zerquera, J.T.; Caveda R, C.A.; Kalberg, O.; Fabelo B, O.; Montalvan E, A.; Cartas A, H.; Leyva F, J.C.

    2006-01-01

    The Center of Protection and Hygiene of the Radiations (CPHR) like center rector of the National Net of Environmental Radiological Surveillance (RNVRA), it has strengthened their detection capacity and of answer before a situation of radiological emergency. The measurements of the absorbed dose rate in air due to the environmental gamma radiation in the main stations of the Net are obtained in real time and the CPHR receives the data coming from these posts at one time relatively short. To improve the operability of the RNVRA it was necessary to complete the facilities of existent monitoring using 4 automatic measurement stations with probes of gamma detection, implementing in this way a measurement system on real time. On the other hand the software were developed: GenironProbeFech, to obtain the data of the probes, DataMail for the shipment of the same ones by electronic mail and GammaRed that receives and processes the data in the rector center. (Author)

  1. Design of Dataflow Monitoring and Searches for B to omega gamma, B to phi gamma and B to phi K-short gamma at BaBar

    Energy Technology Data Exchange (ETDEWEB)

    Swain, J

    2004-03-16

    In May 2003 PEP-II achieved instantaneous luminosities in excess of 6 x 10{sup 33} cm{sup -2}s{sup -1}, twice the design luminosity. To permit BABAR to operate in this challenging environment, development work on the data acquisition system continued after detector commissioning. A vital part of this process is understanding the performance of the data acquisition system. Considerable effort was invested in the design and implementation of an application capable of collecting performance statistics from hundreds of CPUs in the data acquisition system during data collection. The monitoring application and some examples of its operation are presented in this thesis. Also presented here are the searches for the exclusive radiative one-loop decays, B {yields} {omega}{gamma}, B {yields} {phi}{gamma} and B{sup 0} {yields} {phi}K{sub S}{sup 0}{gamma}, using a sample of 89 million B{bar B} events. No significant signal is seen in any of the channels. Upper limits on the branching ratios, {Beta}, were found to be {Beta}(B {yields} {omega}{gamma}) < 3.0 x 10{sup -6}, {Beta}(B {yields} {phi}{gamma}) < 2.9 x 10{sup -6}, and {Beta}(B{sup 0} {yields} {phi}K{sub S}{sup 0}{gamma}) < 3.8 x 10{sup -6}, at the 90% confidence level.

  2. Telecommand and monitoring of automatic recloser through cell phone communication; Telecomando e monitoramento de religadoras automaticas via comunicacao celular

    Energy Technology Data Exchange (ETDEWEB)

    Gardiman, Vitor Luiz G.; Pires Neto, Francisco M.; Rufini, Ricardo; Marques, Rogerio [Bandeirante Energia, Sao Paulo, SP (Brazil)

    2004-02-01

    This article presents the system of tele command and monitoring automatic recloser of the medium voltage distribution network adopted by the Bandeirante Energia, Brazil, by using the cell phone network. The system, installed in 110 automatic reclosers, presented short term availability of tele supervision and tele control, fast installation, and operation and reliability low costs.

  3. Technological and operational structure of the National Automatic Network for Environmental Radiological Monitoring (RENAMORA); Estructura tecnologica y operativa de la Red Nacional Automatica de Monitoreo Radiologico Ambiental RENAMORA

    Energy Technology Data Exchange (ETDEWEB)

    Martinez G, E.; Lopez G, M.; Aguirre G, J.; Fabian O, R.; Hernandez A, Y., E-mail: elias.martinez@cnsns.gob.mx [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Barragan 779, Col. Narvarte, 03020 Ciudad de Mexico (Mexico)

    2015-09-15

    The Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS) in Mexico is a decentralized body, under the Secretaria de Energia whose main mission is to ensure that activities involving nuclear and radioactive materials as well as ionizing radiation sources are carried out with maximum security, considering the current technological developments. In order to monitor the levels of environmental radiation to which the population is exposed, the CNSNS has established a series of radiological monitoring programs that allow characterize the environmental radiation levels in each zone or region in the country; to identify the occurrence of natural or artificial radiological events, such as nuclear tests and accidents in radioactive or nuclear facilities. The National Automatic Network for Environmental Radiological Monitoring (RENAMORA) project was initiated with the support of the IAEA through MEX9/049 project and its purpose is to have a network of instruments that automatically and in real time, transmit information of the gamma radiological environmental status of the national territory and changes occurring in it. This network provides data such as the speed of ambient dose equivalent, temperature and humidity in different regions of the country. The network is composed of 92 stations that are distributed throughout the national territory. The structure of the stations has evolved since its inception, now allowing detection tasks, data transmission and managing them remotely from the main server, which is located in the CNSNS, which is performed a statistical dose for each monitoring station. Each monitoring station is formed in its current structure by a probe detection of gamma radiation, a communication module and associated electronics, a mini Web server DataGATE, a cellular modem and an interface converter. (Author)

  4. Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel

    International Nuclear Information System (INIS)

    Osifo, Otasowie

    2007-03-01

    In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning measurements on 31 spent PWR fuel assemblies performed using the pilot system. The results obtained for the determination of residual heat are presented, showing an agreement of (2-3) % with both calorimetric and calculated data. In addition, the ability to verify declared data such as discharge burnup and cooling time is demonstrated

  5. Calibration and study of the measurement capabilities of real-time gamma spectrometry equipment, developed for the renewal of the network of automatic stations for environmental radiological surveillance of the Generalitat de Catalunya; Calibracion y estudio de las capacidades de medida de loes equipos de espectrometria gamma en tiempo real desarrollados para la renovacion de la Red de Estaciones Automaticas de vigencia radiologica ambiental de la generalitat de Catalunya

    Energy Technology Data Exchange (ETDEWEB)

    Casanovas, R.; Prieto, E.; Salvado, M.

    2013-07-01

    The renewal of the automatic environmental radiation surveillance network of the Gereralitat of Catalunya has been carried out through the development and implementation of gamma-spectrometry-based equipment. The monitors use scintillation cristals, either NaI(Tl) or LaBr{sub 3}(Ce) and currently, there are 3 types of equipment: water radioactivity monitors, aerosols on a particulate filter monitors and direct measurement monitors. In this paper, we expose the basic features of its operation, the details of their calibration and the minimum detectable activity concentrations for some isotopes.

  6. Application of full spectrum analysis technique for NaI(TI) based gamma ray spectral monitoring system

    International Nuclear Information System (INIS)

    Pant, Amar D.; Verma, Amit K.; Narayani, K.; Anilkumar, S.; Singh, Rajvir

    2016-01-01

    NaI(Tl) is commonly used for the gamma spectrometry analysis in laboratories. It continues to be the first choice for gamma spectrometry in many applications even today. Many gamma spectrometric methods are developed to experimentally determine activity of radionuclides in samples. Detectors used worldwide for gamma radiation monitoring are either GM based or scintillator based detector based on count rate. For radiation early warning systems radionuclide specific radiation monitoring methodology is required i.e. gamma ray spectrometry based environmental monitoring system. A computer program has been developed for gamma spectral monitoring by the use of full spectrum analysis (FSA). In this measured spectra are fitted using individual spectral components by least square fitting (LSF). The method is found very useful in situations, where radionuclide specific environmental radiation monitoring is required. The paper describes the details of the FSA procedure for the on line acquisition and analysis of gamma ray spectra from Nal(Tl) detectors

  7. Development of the monitoring system of plasma behavior using a CCD camera in the GAMMA 10 tandem mirror

    International Nuclear Information System (INIS)

    Kawano, Hirokazu; Nakashima, Yousuke; Higashizono, Yuta

    2007-01-01

    In the central-cell of the GAMMA 10 tandem mirror, a medium-speed camera (CCD camera, 400 frames per second, 216 x 640 pixel) has been installed for the observation of plasma behavior. This camera system is designed for monitoring the plasma position and movement in the whole discharge duration. The captured two-dimensional (2-D) images are automatically displayed just after the plasma shot and stored sequentially shot by shot. This system has been established as a helpful tool for optimizing the plasma production and heating systems by measuring the plasma behavior in several experimental conditions. The camera system shows that the intensity of the visible light emission on the central-cell limiter accompanied by central electron cyclotron heating (C-ECH) correlate with the wall conditioning and immersion length of a movable limiter (iris limiter) in the central cell. (author)

  8. Automatized facility for express gamma-spectrometric studies of full-size core and muds of oil-gas wells

    International Nuclear Information System (INIS)

    Antropov, S.Yu.; Ermilov, A.P.; Ermilov, S.A.; Komarov, N.A.; Krokhin, I.I.

    2005-01-01

    In the automatized facility 'Sputnik-Geo' for automated core feeding of the conveyor belt with 5 m length is using. Activity measurement has being conducted by four scintillation gamma radiation detectors. Symmetrical location of the detectors relatively the core allows to exclude of the geometrical uncertainty of component. The spectrum processing and the control by conveyor engine are carried out by computer, which preserves the results of measurements in the database. For density measurement the scintillation detector with collimated source on the 137 Cs radionuclide base is applied. The facility is provided with the light-diode coefficient stabilization of detector amplification, that permits to operation time increase without spectrometers requalification by energy up to 1 working day

  9. ACTIV - a program for automatic processing of gamma-ray spectra

    International Nuclear Information System (INIS)

    Zlokazov, V.B.

    1982-01-01

    Program ACTIV is intended for precise analysis of γ-rays and X-ray spectra and allows the user to carry out the full cycle of automatic processing of a series of spectra, i.e. calibration, automatic peak search, determination of peak positions and areas, identification of the radioisotopes and the transformation of the areas found into masses of isotopes in the irradiated sample. ACTIV uses a complex mathematical technique and is oriented mainly to large computers, but using overlaid loading, it can be run also on small computers like the PDP 11/70. Compared with other similar programs, ACTIV has some advantages in accuracy of peak shape description and in the reliability of the peak search and its least-square analysis. The program can be used for the purpose of activation analysis. The program can analyze spectra with poor statistics and with broad and narrow peaks. (orig.)

  10. Capacitive beam position monitors and automatic beam centering in the transfer lines of Ganil

    International Nuclear Information System (INIS)

    Gudewicz, P.; Petit, E.

    1991-01-01

    A non-interceptive beam position monitor, made of four capacitive electrodes, has been designed at GANIL in order to allow a permanent measurement of the ion beam position over a large intensity range (50 enA to 10 eμA). Signal processing is based on a 10 kHz heterodyne and on an amplitude to phase conversion in order to measure the beam position. An immediate application of these monitors is the automatic beam centering. For this, two algorithms have been developed using the information on the center of gravity given by the beam position monitors which is then fed back to the steerers, an iterative method and a variational method. Both methods have been used on a section of beam line and have given similar and encouraging results. The next step is to center the beam on the completely equipped line. (author) 4 refs., 2 figs., 1 tab

  11. Monitoring system for gamma radiation of porch type for vehicles; Sistema de monitoreo de radiacion gamma tipo portal para vehiculos

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez C, R.M.; Molina, G.; Gutierrez O, E.; Ramirez J, F.J.; Garcia H, J.M.; Aguilar B, M.A.; Vilchis P, A.E.; Cruz E, P.; Torres B, M.A. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2005-07-01

    A monitoring system of gamma radiation for vehicles of the porch type developed in the ININ is presented. This system carries out the radiological monitoring of the vehicles in continuous form, detecting the bottom radiological environment and the presence of nuclear material transported in vehicles. The vehicles are monitored while they pass to low speed through the porch. The detectors are plastic scintillators of great volume that allow high sensibility detection. The arrangement of detecting is interconnected in net, and the data are concentrated on a personal computer whose interface man-machine can be accessed from any personal computer connected to Internet. The system monitoring in real time with options of sampling times from 50 ms configurable up to 500 ms. (Author)

  12. A computer program for automatic gamma-ray spectra analysis with isotope identification for the purpose of activation analysis

    International Nuclear Information System (INIS)

    Weigel, H.; Dauk, J.

    1974-01-01

    A FORTRAN IV program for a PDP-9 computer, with 16K storage capacity, is developed performing automatic analysis of complex gamma-spectra, taken with Ge/Li/ detectors. It searches for full energy peaks and evaluates the peak areas. The program features and automatically performed isotope identifiaction. It is written in such a flexible manner that after reactor irradiation, spectra from samples of any composition can be evaluated for activation analysis. The peak search rutin is based on the following criteria: the counting rate has to increase for two succesive channels; and the amplitude of the corresponding maximum has to be greater than/or equal to F 1 times the statistical error of the counting rate in the valley just before the maximum. In order to detect superimposed peaks, it is assumed that the dependence of FWHM on channel number is roughly approximated by a linear function, and the actual and''theoretical''FWHM values are compared. To determine the net peak area a Gaussian based function is fitted to each peak. The isotope identification is based on the procedure developed by ADAMS and DAMS. (T.G.)

  13. Sleep-monitoring, experiment M133. [electronic recording system for automatic analysis of human sleep patterns

    Science.gov (United States)

    Frost, J. D., Jr.; Salamy, J. G.

    1973-01-01

    The Skylab sleep-monitoring experiment simulated the timelines and environment expected during a 56-day Skylab mission. Two crewmembers utilized the data acquisition and analysis hardware, and their sleep characteristics were studied in an online fashion during a number of all night recording sessions. Comparison of the results of online automatic analysis with those of postmission visual data analysis was favorable, confirming the feasibility of obtaining reliable objective information concerning sleep characteristics during the Skylab missions. One crewmember exhibited definite changes in certain sleep characteristics (e.g., increased sleep latency, increased time Awake during first third of night, and decreased total sleep time) during the mission.

  14. Optical fiber sensor for low dose gamma irradiation monitoring

    Science.gov (United States)

    de Andrés, Ana I.; Esteban, Ã.`scar; Embid, Miguel

    2016-05-01

    An optical fiber gamma ray detector is presented in this work. It is based on a Terbium doped Gadolinium Oxysulfide (Gd2O2S:Tb) scintillating powder which cover a chemically etched polymer fiber tip. This etching improves the fluorescence gathering by the optical fiber. The final diameter has been selected to fulfill the trade-off between light gathering and mechanical strength. Powder has been encapsulated inside a microtube where the fiber tip is immersed. The sensor has been irradiated with different air Kerma doses up to 2 Gy/h with a 137Cs source, and the spectral distribution of the fluorescence intensity has been recorded in a commercial grade CCD spectrometer. The obtained signal-to-noise ratio is good enough even for low doses, which has allowed to reduce the integration time in the spectrometer. The presented results show the feasibility for using low cost equipment to detect/measure ionizing radiation as gamma rays are.

  15. Real-time environmental radiation monitoring system with automatic restoration of backup data in site detector via communication using radio frequency

    International Nuclear Information System (INIS)

    Lee, Wan No; Kim, Eun Han; Chung, Kun Ho; Cho, Young Hyun; Choi, Geun Sik; Lee, Chang Woo; Park, Ki Hyun; Kim, Yun Goo

    2003-01-01

    An environmental radiation monitoring system based on high pressurized ionization chamber has been used for on-line gamma monitoring surrounding the KAERI (Korea Atomic Energy Research Institute), which transmits the dose data measured from ion chamber on the site via radio frequency to a central processing computer and stores the transmitted real-time data. Although communication using ratio frequency has several advantages such as effective and economical transmission, storage, and data process, there is one main disadvantage that data loss during transmission often happens because of unexpected communication problems. It is possible to restore the loss data by off-line such as floppy disk but the simultaneous process and display of current data as well as the backup data are very difficult in the present on-line system. In this work, a new electronic circuit board and the operation software applicable to the conventional environmental radiation monitoring system are developed and the automatical synchronization of the ion chamber unit and the central processing computer is carried out every day. This system is automatically able to restore the backup data within 34 hours without additional equipment and also display together the current data as well as the transmitted backup data after checking time flag

  16. An automatic energy-saving and thermal monitoring/controlling system for a pond

    Directory of Open Access Journals (Sweden)

    Cheng Ching-Chien

    2017-01-01

    Full Text Available Because of low temperatures and oxygen in cold water, fish will die when cold currents arrive. This will cause tremendous loss of money. In order reduce the cooling of the pond, an automatic thermal detecting and cold-roofing system using a wind-proofing device, heaters, and thermal detectors is proposed. To reduce heat loss due to thermal convection above the pond surface, a motor-driven wind-proofing device automatically controlled by a PLC controller is adopted. Here, the wind-proofing device, thermal detectors, and heating system are connected to the PLC controller. The PLC will also be connected to the PC interface. The temperature thresholds used to trigger the heater and the wind proofing device can be set at the PC interface. Two options for manipulating the heating and the automatic heating can be selected. The related wind-proofing area and the number of heaters will be determined according to the current temperature. Moreover, the PLC can be wirelessly connected to the server PC in the control room. The pond keeper can monitor everything online and control the pond water's temperature. With this, the problem of fish dying in a cold wave can be solved. Consequently, to reduce the electrical exhaust when heating up the pond water, green energy, solar energy and wind energy, is used.

  17. Anomaly disentanglement on the basis of automatic processing of the aerial gamma-spectrometric survey data

    International Nuclear Information System (INIS)

    Perlovskij, V.A.; Zaika, S.D.; Lomtadze, V.V.

    1976-01-01

    Automated processing airborne gamma spectrometric data has been introduced with the use of the BESM-4 computer. Discrimination of anomalies is effected using a variable interval 200-300 m within which maximum values in the general counting channel and their coordinates are found; reference points are detected too against which one can determine the excess and amplitude of the anomalies. The discriminated anomalies are fixed on printer and charts of anomalies are constructed. The charts and tables characterizing the anomaly help in the identification of its potentialities and hence underlie a decision to start ground works

  18. Autonomous monitoring of control hardware to predict off-normal conditions using NIF automatic alignment systems

    International Nuclear Information System (INIS)

    Awwal, Abdul A.S.; Wilhelmsen, Karl; Leach, Richard R.; Miller-Kamm, Vicki; Burkhart, Scott; Lowe-Webb, Roger; Cohen, Simon

    2012-01-01

    Highlights: ► An automatic alignment system was developed to process images of the laser beams. ► System uses processing to adjust a series of control loops until alignment criteria are satisfied. ► Monitored conditions are compared against nominal values with an off-normal alert. ► Automated health monitoring system trends off-normals with a large image history. - Abstract: The National Ignition Facility (NIF) is a high power laser system capable of supporting high-energy-density experimentation as a user facility for the next 30 years. In order to maximize the facility availability, preventive maintenance enhancements are being introduced into the system. An example of such an enhancement is a camera-based health monitoring system, integrated into the automated alignment system, which provides an opportunity to monitor trends in measurements such as average beam intensity, size of the beam, and pixel saturation. The monitoring system will generate alerts based on observed trends in measurements to allow scheduled pro-active maintenance before routine off-normal detection stops system operations requiring unscheduled intervention.

  19. Autonomous monitoring of control hardware to predict off-normal conditions using NIF automatic alignment systems

    Energy Technology Data Exchange (ETDEWEB)

    Awwal, Abdul A.S., E-mail: awwal1@llnl.gov [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Wilhelmsen, Karl; Leach, Richard R.; Miller-Kamm, Vicki; Burkhart, Scott; Lowe-Webb, Roger; Cohen, Simon [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer An automatic alignment system was developed to process images of the laser beams. Black-Right-Pointing-Pointer System uses processing to adjust a series of control loops until alignment criteria are satisfied. Black-Right-Pointing-Pointer Monitored conditions are compared against nominal values with an off-normal alert. Black-Right-Pointing-Pointer Automated health monitoring system trends off-normals with a large image history. - Abstract: The National Ignition Facility (NIF) is a high power laser system capable of supporting high-energy-density experimentation as a user facility for the next 30 years. In order to maximize the facility availability, preventive maintenance enhancements are being introduced into the system. An example of such an enhancement is a camera-based health monitoring system, integrated into the automated alignment system, which provides an opportunity to monitor trends in measurements such as average beam intensity, size of the beam, and pixel saturation. The monitoring system will generate alerts based on observed trends in measurements to allow scheduled pro-active maintenance before routine off-normal detection stops system operations requiring unscheduled intervention.

  20. Automatic modal identification of cable-supported bridges instrumented with a long-term monitoring system

    Science.gov (United States)

    Ni, Y. Q.; Fan, K. Q.; Zheng, G.; Chan, T. H. T.; Ko, J. M.

    2003-08-01

    An automatic modal identification program is developed for continuous extraction of modal parameters of three cable-supported bridges in Hong Kong which are instrumented with a long-term monitoring system. The program employs the Complex Modal Indication Function (CMIF) algorithm to identify modal properties from continuous ambient vibration measurements in an on-line manner. By using the LabVIEW graphical programming language, the software realizes the algorithm in Virtual Instrument (VI) style. The applicability and implementation issues of the developed software are demonstrated by using one-year measurement data acquired from 67 channels of accelerometers deployed on the cable-stayed Ting Kau Bridge. With the continuously identified results, normal variability of modal vectors caused by varying environmental and operational conditions is observed. Such observation is very helpful for selection of appropriate measured modal vectors for structural health monitoring applications.

  1. Rheticus Displacement: an Automatic Geo-Information Service Platform for Ground Instabilities Detection and Monitoring

    Science.gov (United States)

    Chiaradia, M. T.; Samarelli, S.; Agrimano, L.; Lorusso, A. P.; Nutricato, R.; Nitti, D. O.; Morea, A.; Tijani, K.

    2016-12-01

    Rheticus® is an innovative cloud-based data and services hub able to deliver Earth Observation added-value products through automatic complex processes and a minimum interaction with human operators. This target is achieved by means of programmable components working as different software layers in a modern enterprise system which relies on SOA (service-oriented-architecture) model. Due to its architecture, where every functionality is well defined and encapsulated in a standalone component, Rheticus is potentially highly scalable and distributable allowing different configurations depending on the user needs. Rheticus offers a portfolio of services, ranging from the detection and monitoring of geohazards and infrastructural instabilities, to marine water quality monitoring, wildfires detection or land cover monitoring. In this work, we outline the overall cloud-based platform and focus on the "Rheticus Displacement" service, aimed at providing accurate information to monitor movements occurring across landslide features or structural instabilities that could affect buildings or infrastructures. Using Sentinel-1 (S1) open data images and Multi-Temporal SAR Interferometry techniques (i.e., SPINUA), the service is complementary to traditional survey methods, providing a long-term solution to slope instability monitoring. Rheticus automatically browses and accesses (on a weekly basis) the products of the rolling archive of ESA S1 Scientific Data Hub; S1 data are then handled by a mature running processing chain, which is responsible of producing displacement maps immediately usable to measure with sub-centimetric precision movements of coherent points. Examples are provided, concerning the automatic displacement map generation process, as well as the integration of point and distributed scatterers, the integration of multi-sensors displacement maps (e.g., Sentinel-1 IW and COSMO-SkyMed HIMAGE), the combination of displacement rate maps acquired along both ascending

  2. A Cloud-Based System for Automatic Hazard Monitoring from Sentinel-1 SAR Data

    Science.gov (United States)

    Meyer, F. J.; Arko, S. A.; Hogenson, K.; McAlpin, D. B.; Whitley, M. A.

    2017-12-01

    Despite the all-weather capabilities of Synthetic Aperture Radar (SAR), and its high performance in change detection, the application of SAR for operational hazard monitoring was limited in the past. This has largely been due to high data costs, slow product delivery, and limited temporal sampling associated with legacy SAR systems. Only since the launch of ESA's Sentinel-1 sensors have routinely acquired and free-of-charge SAR data become available, allowing—for the first time—for a meaningful contribution of SAR to disaster monitoring. In this paper, we present recent technical advances of the Sentinel-1-based SAR processing system SARVIEWS, which was originally built to generate hazard products for volcano monitoring centers. We outline the main functionalities of SARVIEWS including its automatic database interface to Sentinel-1 holdings of the Alaska Satellite Facility (ASF), and its set of automatic processing techniques. Subsequently, we present recent system improvements that were added to SARVIEWS and allowed for a vast expansion of its hazard services; specifically: (1) In early 2017, the SARVIEWS system was migrated into the Amazon Cloud, providing access to cloud capabilities such as elastic scaling of compute resources and cloud-based storage; (2) we co-located SARVIEWS with ASF's cloud-based Sentinel-1 archive, enabling the efficient and cost effective processing of large data volumes; (3) we integrated SARVIEWS with ASF's HyP3 system (http://hyp3.asf.alaska.edu/), providing functionality such as subscription creation via API or map interface as well as automatic email notification; (4) we automated the production chains for seismic and volcanic hazards by integrating SARVIEWS with the USGS earthquake notification service (ENS) and the USGS eruption alert system. Email notifications from both services are parsed and subscriptions are automatically created when certain event criteria are met; (5) finally, SARVIEWS-generated hazard products are now

  3. Quality assurance of gamma spectrometry in monitoring network of CSFR

    International Nuclear Information System (INIS)

    Malatova, I.; Drabova, D.; Bucina, I.

    2004-01-01

    On the basis of the Chernobyl experience the Czechoslovak government decided in July 1986 to set up Czechoslovak Monitoring Network and to assign the Centre of Radiation Hygiene of the Institute of Hygiene and Epidemiology to be its headquarters (Centre of Czechoslovak Monitoring Network). The requirements for emergency monitoring are stated in the document The principles of Monitoring for Protection of Public Health in case of a Radiation Accident approved by the Czechoslovak government in April 1987. Assignments of components of the Network, equipment and technical support required, aims of their activities and chronological order of their activation are stated in the document Requirements on Monitoring, Setting up and Equipment of the Czechoslovak Monitoring Network drawn up by the Centre and approved by the Czechoslovak Governmental Commission for Coordination of the Measures in Case of a Radiation Accident in April 1988. It should be noted, however, that basic principles of environmental monitoring aimed at obtaining the complete information of radiation situation, discharges and releases of radionuclides both during the normal operation and in case of an accident were worked on since putting the first PWR-type NPP in Czechoslovakia into operation in 1979. In March 1986 the Instruction for emergency monitoring was approved by the commission. The existence of this instruction and corresponding professional, technical and organizational preparedness of organizations departments responsible for monitoring manifested its positive impact especially in the situation after the Chernobyl accident. This fact refers especially to institutions of hygienic service and nuclear power engineering. National and international experience gained after the Chernobyl accident led to some elaboration in the organization of monitoring and to more precise definition of its conception

  4. A novel automatic method for monitoring Tourette motor tics through a wearable device.

    Science.gov (United States)

    Bernabei, Michel; Preatoni, Ezio; Mendez, Martin; Piccini, Luca; Porta, Mauro; Andreoni, Giuseppe

    2010-09-15

    The aim of this study was to propose a novel automatic method for quantifying motor-tics caused by the Tourette Syndrome (TS). In this preliminary report, the feasibility of the monitoring process was tested over a series of standard clinical trials in a population of 12 subjects affected by TS. A wearable instrument with an embedded three-axial accelerometer was used to detect and classify motor tics during standing and walking activities. An algorithm was devised to analyze acceleration data by: eliminating noise; detecting peaks connected to pathological events; and classifying intensity and frequency of motor tics into quantitative scores. These indexes were compared with the video-based ones provided by expert clinicians, which were taken as the gold-standard. Sensitivity, specificity, and accuracy of tic detection were estimated, and an agreement analysis was performed through the least square regression and the Bland-Altman test. The tic recognition algorithm showed sensitivity = 80.8% ± 8.5% (mean ± SD), specificity = 75.8% ± 17.3%, and accuracy = 80.5% ± 12.2%. The agreement study showed that automatic detection tended to overestimate the number of tics occurred. Although, it appeared this may be a systematic error due to the different recognition principles of the wearable and video-based systems. Furthermore, there was substantial concurrency with the gold-standard in estimating the severity indexes. The proposed methodology gave promising performances in terms of automatic motor-tics detection and classification in a standard clinical context. The system may provide physicians with a quantitative aid for TS assessment. Further developments will focus on the extension of its application to everyday long-term monitoring out of clinical environments. © 2010 Movement Disorder Society.

  5. Automatic Crack Detection and Classification Method for Subway Tunnel Safety Monitoring

    Directory of Open Access Journals (Sweden)

    Wenyu Zhang

    2014-10-01

    Full Text Available Cracks are an important indicator reflecting the safety status of infrastructures. This paper presents an automatic crack detection and classification methodology for subway tunnel safety monitoring. With the application of high-speed complementary metal-oxide-semiconductor (CMOS industrial cameras, the tunnel surface can be captured and stored in digital images. In a next step, the local dark regions with potential crack defects are segmented from the original gray-scale images by utilizing morphological image processing techniques and thresholding operations. In the feature extraction process, we present a distance histogram based shape descriptor that effectively describes the spatial shape difference between cracks and other irrelevant objects. Along with other features, the classification results successfully remove over 90% misidentified objects. Also, compared with the original gray-scale images, over 90% of the crack length is preserved in the last output binary images. The proposed approach was tested on the safety monitoring for Beijing Subway Line 1. The experimental results revealed the rules of parameter settings and also proved that the proposed approach is effective and efficient for automatic crack detection and classification.

  6. Automatic crack detection and classification method for subway tunnel safety monitoring.

    Science.gov (United States)

    Zhang, Wenyu; Zhang, Zhenjiang; Qi, Dapeng; Liu, Yun

    2014-10-16

    Cracks are an important indicator reflecting the safety status of infrastructures. This paper presents an automatic crack detection and classification methodology for subway tunnel safety monitoring. With the application of high-speed complementary metal-oxide-semiconductor (CMOS) industrial cameras, the tunnel surface can be captured and stored in digital images. In a next step, the local dark regions with potential crack defects are segmented from the original gray-scale images by utilizing morphological image processing techniques and thresholding operations. In the feature extraction process, we present a distance histogram based shape descriptor that effectively describes the spatial shape difference between cracks and other irrelevant objects. Along with other features, the classification results successfully remove over 90% misidentified objects. Also, compared with the original gray-scale images, over 90% of the crack length is preserved in the last output binary images. The proposed approach was tested on the safety monitoring for Beijing Subway Line 1. The experimental results revealed the rules of parameter settings and also proved that the proposed approach is effective and efficient for automatic crack detection and classification.

  7. Alarm criteria for the fixed gamma radiation monitoring stations

    International Nuclear Information System (INIS)

    Kjelle, P.E.

    1987-01-01

    For the type of measurement considered here, an alarm based on the dose excess has been shown to be a more certain method of indicating that a true alarm situation exists than an alarm based on the dose-rate exceeding a given dose-rate level. The method offers a number of advantages: Dose-rate levels can be recorded over long periods without any necessity of making manual changes in the alarm level due to seasonal variations in the background level. A relatively low level can be specified without an unnecessary number of false alarms being triggered by gamma-emitting radon daughters. (orig./HP)

  8. Tritium monitor with improved gamma-ray discrimination

    Science.gov (United States)

    Cox, Samson A.; Bennett, Edgar F.; Yule, Thomas J.

    1985-01-01

    Apparatus and method for selective measurement of tritium oxide in an environment which may include other radioactive components and gamma radiation, the measurement including the selective separation of tritium oxide from a sample gas through a membrane into a counting gas, the generation of electrical pulses individually representative by rise times of tritium oxide and other radioactivity in the counting gas, separation of the pulses by rise times, and counting of those pulses representative of tritium oxide. The invention further includes the separate measurement of any tritium in the sample gas by oxidizing the tritium to tritium oxide and carrying out a second separation and analysis procedure as described above.

  9. Development of a Compact Gamma-ray Detector for a Neural-Network Radiation Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Kim, H. S.; Ha, J. H.; Lee, K. H. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lee, C. H. [Hanyang Univ., Seoul (Korea, Republic of)

    2012-03-15

    Radiation monitoring is very important to secure safety in nuclear-related facilities and against nuclear terrorism. For wide range of radiation monitoring, neutral network system of radiation detection is most efficient way. Thus, a compact radiation detector is useful to install in wide range to be concerned. A compact gamma-ray detector was fabricated by using a CsI(Tl) scintillator, which was matched with the formerly developed PIN photodiode, for a neural network radiation monitoring. At room temperature, the fabricated compact gamma-ray detector demonstrates an energy resolution of 13.3 % for 662 keV 6.9% for 1330 keV. The compactness, the low-voltage power consumption and the physical hardness are very useful features for a neural network radiation monitoring. In this study, characteristics of a fabricated compact gamma-ray detector were presented. An important aspect to consider in a neural-network radiation monitoring such as reaction probability of the fabricated compact detector for angle of incident gamma-ray was also addressed.

  10. Method for monitoring drilling materials for gamma ray activity

    International Nuclear Information System (INIS)

    Smith, H.D. Jr.; Arnold, D.M.; Schultz, W.E.

    1985-01-01

    This invention relates to a method of verifying the radioactivity levels in raw barite prior to its use in drilling mud. Certain gamma ray measurements are taken of the raw barite and extrapolated to a well bore environment using the projected drilling mud weight made from this barite and the dimensions of the well bore. The natural radioactivity occurring in the formations in the vicinity of the well bore is then compared with the projected levels to enable a determination of whether or not the barite has sufficient radioactive trace elements to forbid its use in a well. Alternatively, the method indicates the ratios by which such additives containing radioactive trace elements must be diluted with non-radioactive additives before use in the drilling mud. A second use of the method involves mud testing at the well site for radioactivity from mud additives, including barite, potassium chloride, and well cuttings. Additional uses include testing other weight materials prior to or subsequent to addition to the mud, and methods for correcting observed gamma ray measurements for the mud-induced background

  11. Development of AN Open-Source Automatic Deformation Monitoring System for Geodetical and Geotechnical Measurements

    Science.gov (United States)

    Engel, P.; Schweimler, B.

    2016-04-01

    The deformation monitoring of structures and buildings is an important task field of modern engineering surveying, ensuring the standing and reliability of supervised objects over a long period. Several commercial hardware and software solutions for the realization of such monitoring measurements are available on the market. In addition to them, a research team at the Neubrandenburg University of Applied Sciences (NUAS) is actively developing a software package for monitoring purposes in geodesy and geotechnics, which is distributed under an open source licence and free of charge. The task of managing an open source project is well-known in computer science, but it is fairly new in a geodetic context. This paper contributes to that issue by detailing applications, frameworks, and interfaces for the design and implementation of open hardware and software solutions for sensor control, sensor networks, and data management in automatic deformation monitoring. It will be discussed how the development effort of networked applications can be reduced by using free programming tools, cloud computing technologies, and rapid prototyping methods.

  12. Monitoring caustic injuries from emergency department databases using automatic keyword recognition software.

    Science.gov (United States)

    Vignally, P; Fondi, G; Taggi, F; Pitidis, A

    2011-03-31

    In Italy the European Union Injury Database reports the involvement of chemical products in 0.9% of home and leisure accidents. The Emergency Department registry on domestic accidents in Italy and the Poison Control Centres record that 90% of cases of exposure to toxic substances occur in the home. It is not rare for the effects of chemical agents to be observed in hospitals, with a high potential risk of damage - the rate of this cause of hospital admission is double the domestic injury average. The aim of this study was to monitor the effects of injuries caused by caustic agents in Italy using automatic free-text recognition in Emergency Department medical databases. We created a Stata software program to automatically identify caustic or corrosive injury cases using an agent-specific list of keywords. We focused attention on the procedure's sensitivity and specificity. Ten hospitals in six regions of Italy participated in the study. The program identified 112 cases of injury by caustic or corrosive agents. Checking the cases by quality controls (based on manual reading of ED reports), we assessed 99 cases as true positive, i.e. 88.4% of the patients were automatically recognized by the software as being affected by caustic substances (99% CI: 80.6%- 96.2%), that is to say 0.59% (99% CI: 0.45%-0.76%) of the whole sample of home injuries, a value almost three times as high as that expected (p < 0.0001) from European codified information. False positives were 11.6% of the recognized cases (99% CI: 5.1%- 21.5%). Our automatic procedure for caustic agent identification proved to have excellent product recognition capacity with an acceptable level of excess sensitivity. Contrary to our a priori hypothesis, the automatic recognition system provided a level of identification of agents possessing caustic effects that was significantly much greater than was predictable on the basis of the values from current codifications reported in the European Database.

  13. Automatic system for ecological monitoring of ambient air in the region of energy complex 'Maritsa-Iztok'

    International Nuclear Information System (INIS)

    Vasilev, V.; Videnova, I.; Nedyalkov, N.

    2000-01-01

    This report presents the automatic system for ecological monitoring of ambient air in the region of the energy complex 'Maritza-Iztok', developed by CCS-Bulgaria, Bulgarian Academy of Sciences, Institute of Control and System Research. The automatic station takes the concentration of nitric oxides, sulfuric dioxide and dust, as well as the meteorological indicators: temperature and humidity, atmospheric pressure, wind direction and speed, sun heat and radiation. The data appears on a information board and is kept in a database

  14. MOXE: An X-ray all-sky monitor for Soviet Spectrum-X-Gamma Mission

    Science.gov (United States)

    Priedhorsky, W.; Fenimore, E. E.; Moss, C. E.; Kelley, R. L.; Holt, S. S.

    1989-01-01

    A Monitoring Monitoring X-Ray Equipment (MOXE) is being developed for the Soviet Spectrum-X-Gamma Mission. MOXE is an X-ray all-sky monitor based on array of pinhole cameras, to be provided via a collaboration between Goddard Space Flight Center and Los Alamos National Laboratory. The objectives are to alert other observers on Spectrum-X-Gamma and other platforms of interesting transient activity, and to synoptically monitor the X-ray sky and study long-term changes in X-ray binaries. MOXE will be sensitive to sources as faint as 2 milliCrab (5 sigma) in 1 day, and cover the 2 to 20 KeV band.

  15. Terrestrial Gamma-Ray Flashes (TGFs) Observed with the Fermi-Gamma-Ray Burst Monitor: The First Hundred TGFs

    Science.gov (United States)

    Fishman, G J.; Briggs, M. S.; Connaughton, V.; Bhat, P. N.

    2010-01-01

    The Gamma-ray Burst Monitor (GBM) on the Fermi Gamma-ray Space Telescope Observatory (Fermi) is now detecting 2.1 TGFs per week. At this rate, nearly a hundred TGFs will have been detected by the time of this Meeting. This rate has increased by a factor of 8 since new flight software was uploaded to the spacecraft in November 2009 in order to increase the sensitivity of GBM to TGFs. The high time resolution (2 microseconds) allows temporal features to be resolved so that some insight may be gained on the origin and transport of the gamma-ray photons through the atmosphere. The absolute time of the TGFs, known to several microseconds, also allows accurate correlations of TGFs with lightning networks and other lightning-related phenomena. The thick bismuth germanate (BGO) scintillation detectors of the GBM system have observed photon energies from TGFs at energies above 40 MeV. New results on the some temporal aspects of TGFs will be presented.

  16. Terrestrial Gamma-ray Flashes (TGFs) Observed with the Fermi-Gamma-ray Burst Monitor: Temporal and Spectral Properties

    Science.gov (United States)

    Fishman, G. J.; Briggs, M. S.; Connaughton, W.; Wilson-Hodge, C.; Bhat, P. N.

    2010-01-01

    The Gamma-ray Burst Monitor (GBM) on the Fermi Gamma-ray Space Telescope Observatory (Fermi) was detecting 2.1 TGFs per week. This rate has increased by a factor of 8 since new flight software was uploaded to the spacecraft in November 2009 in order to increase the sensitivity of GBM to TGFs. Further upgrades to Fermi-GBM to allow observations of weaker TGFs are in progress. The high time resolution (2 s) allows temporal features to be resolved so that some insight may be gained on the origin and transport of the gamma-ray photons through the atmosphere. The absolute time of the TGFs, known to several microseconds, also allows accurate correlations of TGFs with lightning networks and other lightning-related phenomena. The thick bismuth germanate (BGO) scintillation detectors of the GBM system have observed photon energies from TGFs at energies above 40 MeV. New results on the some temporal aspects of TGFs will be presented along with spectral characteristics and properties of several electron-positron TGF events that have been identified.

  17. Sampling optimization trade-offs for long-term monitoring of gamma dose rates

    NARCIS (Netherlands)

    Melles, S.J.; Heuvelink, G.B.M.; Twenhöfel, C.J.W.; Stöhlker, U.

    2008-01-01

    This paper applies a recently developed optimization method to examine the design of networks that monitor radiation under routine conditions. Annual gamma dose rates were modelled by combining regression with interpolation of the regression residuals using spatially exhaustive predictors and an

  18. Area and environmental gamma dose monitoring at PINSTECH

    International Nuclear Information System (INIS)

    Javed, M.; Awan, M.A.; Ahmad, S.; Afsar, M.; Orfi, S.D.

    1986-11-01

    Radiation dose monitoring of various radioactive laboratories including PARR building, radioactive waste disposal area and the environment upto initial peripheral limits of PINSTECH has been carried out by TLD's installed at different locations. Average dose rates in terms of percentage of dose limits have been compiled. The results for the year 1985 have been discussed in this report. (author)

  19. Workflow-centred evaluation of an automatic lesion tracking software for chemotherapy monitoring by CT

    Energy Technology Data Exchange (ETDEWEB)

    Moltz, Jan Hendrik; Peitgen, Heinz-Otto [Fraunhofer MEVIS - Institute for Medical Image Computing, Bremen (Germany); D' Anastasi, Melvin [University Hospital Munich-Grosshadern, Department of Clinical Radiology, Muenchen (Germany); Kiessling, Andreas [University Hospital Giessen and Marburg, Department of Diagnostic Radiology, Marburg (Germany); Pinto dos Santos, Daniel [University Hospital Mainz, Department of Diagnostic and Interventional Radiology, Mainz (Germany); Schuelke, Christoph [University Hospital Muenster, Institute of Clinical Radiology, Muenster (Germany)

    2012-12-15

    In chemotherapy monitoring, an estimation of the change in tumour size is an important criterion for the assessment of treatment success. This requires a comparison between corresponding lesions in the baseline and follow-up computed tomography (CT) examinations. We evaluate the clinical benefits of an automatic lesion tracking tool that identifies the target lesions in the follow-up CT study and pre-computes the lesion volumes. Four radiologists performed volumetric follow-up examinations for 52 patients with and without lesion tracking. In total, 139 lung nodules, liver metastases and lymph nodes were given as target lesions. We measured reading time, inter-reader variability in lesion identification and volume measurements, and the amount of manual adjustments of the segmentation results. With lesion tracking, target lesion assessment time decreased by 38 % or 22 s per lesion. Relative volume difference between readers was reduced from 0.171 to 0.1. Segmentation quality was comparable with and without lesion tracking. Our automatic lesion tracking tool can make interpretation of follow-up CT examinations quicker and provide results that are less reader-dependent. (orig.)

  20. Seismo-Geochemical Variations in SW Taiwan: Multi-Parameter Automatic Gas Monitoring Results

    Science.gov (United States)

    Yang, T. F.; Fu, C.-C.; Walia, V.; Chen, C.-H.; Chyi, L. L.; Liu, T.-K.; Song, S.-R.; Lee, M.; Lin, C.-W.; Lin, C.-C.

    2006-04-01

    Gas variations of many mud volcanoes and hot springs distributed along the tectonic sutures in southwestern Taiwan are considered to be sensitive to the earthquake activity. Therefore, a multi-parameter automatic gas station was built on the bank of one of the largest mud-pools at an active fault zone of southwestern Taiwan, for continuous monitoring of CO2, CH4, N2 and H2O, the major constituents of its bubbling gases. During the year round monitoring from October 2001 to October 2002, the gas composition, especially, CH4 and CO2, of the mud pool showed significant variations. Taking the CO2/CH4 ratio as the main indicator, anomalous variations can be recognized from a few days to a few weeks before earthquakes and correlated well with those with a local magnitude >4.0 and local intensities >2. It is concluded that the gas composition in the area is sensitive to the local crustal stress/strain and is worthy to conduct real-time monitoring for the seismo-geochemical precursors.

  1. Wireless sensor network-based greenhouse environment monitoring and automatic control system for dew condensation prevention.

    Science.gov (United States)

    Park, Dae-Heon; Park, Jang-Woo

    2011-01-01

    Dew condensation on the leaf surface of greenhouse crops can promote diseases caused by fungus and bacteria, affecting the growth of the crops. In this paper, we present a WSN (Wireless Sensor Network)-based automatic monitoring system to prevent dew condensation in a greenhouse environment. The system is composed of sensor nodes for collecting data, base nodes for processing collected data, relay nodes for driving devices for adjusting the environment inside greenhouse and an environment server for data storage and processing. Using the Barenbrug formula for calculating the dew point on the leaves, this system is realized to prevent dew condensation phenomena on the crop's surface acting as an important element for prevention of diseases infections. We also constructed a physical model resembling the typical greenhouse in order to verify the performance of our system with regard to dew condensation control.

  2. Wireless Sensor Network-Based Greenhouse Environment Monitoring and Automatic Control System for Dew Condensation Prevention

    Science.gov (United States)

    Park, Dae-Heon; Park, Jang-Woo

    2011-01-01

    Dew condensation on the leaf surface of greenhouse crops can promote diseases caused by fungus and bacteria, affecting the growth of the crops. In this paper, we present a WSN (Wireless Sensor Network)-based automatic monitoring system to prevent dew condensation in a greenhouse environment. The system is composed of sensor nodes for collecting data, base nodes for processing collected data, relay nodes for driving devices for adjusting the environment inside greenhouse and an environment server for data storage and processing. Using the Barenbrug formula for calculating the dew point on the leaves, this system is realized to prevent dew condensation phenomena on the crop’s surface acting as an important element for prevention of diseases infections. We also constructed a physical model resembling the typical greenhouse in order to verify the performance of our system with regard to dew condensation control. PMID:22163813

  3. Dose profile monitoring with carbon ions by means of prompt-gamma measurements

    Energy Technology Data Exchange (ETDEWEB)

    Testa, E. [Institut de Physique Nucleaire de Lyon, Universite de Lyon, F-69003 Lyon, Universite Lyon 1 and IN2P3/CNRS, UMR 5822, F-69622 Villeurbanne (France)], E-mail: e.testa@ipnl.in2p3.fr; Bajard, M.; Chevallier, M.; Dauvergne, D.; Le Foulher, F. [Institut de Physique Nucleaire de Lyon, Universite de Lyon, F-69003 Lyon, Universite Lyon 1 and IN2P3/CNRS, UMR 5822, F-69622 Villeurbanne (France); Freud, N.; Letang, J.M. [Institut National des Sciences Appliquees de Lyon, Laboratoire de Controle Non-Destructif par Rayonnements Ionisants (France); Poizat, J.C.; Ray, C.; Testa, M. [Institut de Physique Nucleaire de Lyon, Universite de Lyon, F-69003 Lyon, Universite Lyon 1 and IN2P3/CNRS, UMR 5822, F-69622 Villeurbanne (France)

    2009-03-15

    A key point in the quality control of ion therapy is real-time monitoring and imaging of the dose delivered to the patient. Among the possible signals that can be used to make such a monitoring, prompt gamma-rays issued from nuclear fragmentation are possible candidates, provided the correlation between the emission profile and the primary beam range can be established. By means of simultaneous energy and time-of-flight discrimination, we could measure the longitudinal profile of the prompt gamma-rays emitted by 73 MeV/u carbon ions stopping inside a PMMA target. This technique allowed us to minimize the shielding against neutrons and scattered gamma rays, and to find a good correlation between the prompt-gamma profile and the ion range. This profile was studied as a function of the observation angle. By extrapolating our results to higher energies and realistic detection efficiencies, we showed that prompt gamma-ray measurements make it feasible to control in real time the longitudinal dose during ion therapy treatments.

  4. Indoor gamma radiation monitoring In Rawalpindi, Pakistan using TLD100

    International Nuclear Information System (INIS)

    Azam, Sana; Tufail, Muhammad; Sohail, Muhammad

    2008-01-01

    Full text: Natural radioactivity originates from extraterrestrial sources as well as from radioactive elements in earth's crust. The amount of radioactivity varies from place to place and with altitude. The aim of this study was to observe the indoor radiation level in Rawalpindi using TLD. For this purpose LiF:Mg:Ti (TLD100) chips were used. Chips were annealed and then calibrated using different sources and the calibration factor obtained by using Cs137 source was selected for dose estimation. Its value was 0.1403 μGy/TL response. Rawalpindi categorized into six regions. In each region, 5 cemented houses were selected and TLD 100 chips were placed at a distance of 0.5 m from ground the level. Chips were properly covered to protect them from ultraviolet light and moisture and were placed for three months. The average annual indoor dose rate for Rawalpindi was estimated to be 392.105μGy/yr and average dose to be 97.65μGy. Therefore, the effective dose for population of Rawalpindi from indoor gamma radiation was estimated to be 313.68μSv/yr using an indoor occupancy factor of 80%. (author)

  5. Automatic monitoring of ecosystem structure and functions using integrated low-cost near surface sensors

    Science.gov (United States)

    Kim, J.; Ryu, Y.; Jiang, C.; Hwang, Y.

    2016-12-01

    Near surface sensors are able to acquire more reliable and detailed information with higher temporal resolution than satellite observations. Conventional near surface sensors usually work individually, and thus they require considerable manpower from data collection through information extraction and sharing. Recent advances of Internet of Things (IoT) provides unprecedented opportunities to integrate various low-cost sensors as an intelligent near surface observation system for monitoring ecosystem structure and functions. In this study, we developed a Smart Surface Sensing System (4S), which can automatically collect, transfer, process and analyze data, and then publish time series results on public-available website. The system is composed of micro-computer Raspberry pi, micro-controller Arduino, multi-spectral spectrometers made from Light Emitting Diode (LED), visible and near infrared cameras, and Internet module. All components are connected with each other and Raspberry pi intelligently controls the automatic data production chain. We did intensive tests and calibrations in-lab. Then, we conducted in-situ observations at a rice paddy field and a deciduous broadleaf forest. During the whole growth season, 4S obtained landscape images, spectral reflectance in red, green, blue, and near infrared, normalized difference vegetation index (NDVI), fraction of photosynthetically active radiation (fPAR), and leaf area index (LAI) continuously. Also We compared 4S data with other independent measurements. NDVI obtained from 4S agreed well with Jaz hyperspectrometer at both diurnal and seasonal scales (R2 = 0.92, RMSE = 0.059), and 4S derived fPAR and LAI were comparable to LAI-2200 and destructive measurements in both magnitude and seasonal trajectory. We believe that the integrated low-cost near surface sensor could help research community monitoring ecosystem structure and functions closer and easier through a network system.

  6. Use of self-powered detectors of near containment gamma monitoring

    International Nuclear Information System (INIS)

    Kemp, J.; LaFontaine, M.; Sharma, H.

    2001-01-01

    A study was conducted during the period April to May 1988, to select a self-powered detector (SPD) with an appropriate emitter for measuring the gamma radiation dose rate in near-containment. The selected SPD would be used in the containment monitoring systems for the Ringhals and Forsmark reactors in Sweden. In-containment gamma radiation (81 keV to ∼3 MeV energy range) could result from the release of gaseous fission-product nuclides of bromine, krypton, iodine and xenon. Associated dose rates can range from 10 to 10 6 Gy/h. Tests were performed on platinum and vanadium emitter SPDs 1 using 60 Co, 192 Ir and X-ray gamma/photon sources. A gamma energy dependent polarity change in the signal from the Pt SPD (signal goes from positive to negative as energy drops below 100 keV), coupled with a non-linear response, eliminated that design from further study in this application. The vanadium SPDs produced a linear, negative signal irrespective of the impingent gamma energy level. The gamma sensitivity of the 18 V SPDs tested in the program, ranged from -1.07 x 10 -14 A/Gy/h to -1.87 x 10 -14 A/Gy/h per metre emitter length. (author)

  7. MODULAR CAUSTIC SIDE SOLVENT EXTRACTION UNIT (MCU) GAMMA MONITORS SYSTEM FINAL REPORT

    Energy Technology Data Exchange (ETDEWEB)

    Casella, V

    2005-12-15

    The Department of Energy (DOE) selected Caustic-Side Solvent Extraction (CSSX) as the preferred technology for the removal of radioactive cesium from High-Level Waste (HLW) at the Savannah River Site (SRS). Before the full-scale Salt Waste Processing Facility (SWPF) becomes operational, the Closure Business Unit (CBU) plans to process a portion of dissolved saltcake waste through a Modular CSSX Unit (MCU). This work was derived from Technical Task Request SP-TTR-2004-00013, ''Gamma Monitor for MCU''. The deliverables for this task are the hardware and software for the gamma monitors and a report summarizing the testing and acceptance of this equipment for use in the MCU. Gamma-ray monitors are required to: (1) Measure the Cs-137 concentration in the decontaminated salt solution before entering the DSS (Decontaminated Salt Solution) Hold Tank, (2) Measure the Cs-137 concentration in the strip effluent before entering the Strip Effluent Hold Tank, (3) Verify proper operation of the solvent extraction system by verifying material balance within the process (The DSS Hold Tank Cs-137 concentration will be very low and the Cs-137 concentration in the Strip Effluent Hold Tank will be fifteen times higher than the Cs-137 concentration in the Feed Tank.) Sodium iodide monitors are used to measure the Cs-137 concentration in the piping before the DSS Hold tank, while GM monitors are used for Cs-137 measurements before the Strip Effluent Hold Tank. Tungsten shields were designed using Monte Carlo calculations and fabricated to reduce the process background radiation at the detector positions. These monitors were calibrated with NIST traceable standards that were specially made to be the same as the piping being monitored. Since this gamma ray monitoring system is unique, specially designed software was written and acceptance tested by Savannah River National Laboratory personnel. The software is a LabView-based application that serves as a unified

  8. MODULAR CAUSTIC SIDE SOLVENT EXTRACTION UNIT (MCU) GAMMA MONITORS SYSTEM FINAL REPORT

    International Nuclear Information System (INIS)

    Casella, V

    2005-01-01

    The Department of Energy (DOE) selected Caustic-Side Solvent Extraction (CSSX) as the preferred technology for the removal of radioactive cesium from High-Level Waste (HLW) at the Savannah River Site (SRS). Before the full-scale Salt Waste Processing Facility (SWPF) becomes operational, the Closure Business Unit (CBU) plans to process a portion of dissolved saltcake waste through a Modular CSSX Unit (MCU). This work was derived from Technical Task Request SP-TTR-2004-00013, ''Gamma Monitor for MCU''. The deliverables for this task are the hardware and software for the gamma monitors and a report summarizing the testing and acceptance of this equipment for use in the MCU. Gamma-ray monitors are required to: (1) Measure the Cs-137 concentration in the decontaminated salt solution before entering the DSS (Decontaminated Salt Solution) Hold Tank, (2) Measure the Cs-137 concentration in the strip effluent before entering the Strip Effluent Hold Tank, (3) Verify proper operation of the solvent extraction system by verifying material balance within the process (The DSS Hold Tank Cs-137 concentration will be very low and the Cs-137 concentration in the Strip Effluent Hold Tank will be fifteen times higher than the Cs-137 concentration in the Feed Tank.) Sodium iodide monitors are used to measure the Cs-137 concentration in the piping before the DSS Hold tank, while GM monitors are used for Cs-137 measurements before the Strip Effluent Hold Tank. Tungsten shields were designed using Monte Carlo calculations and fabricated to reduce the process background radiation at the detector positions. These monitors were calibrated with NIST traceable standards that were specially made to be the same as the piping being monitored. Since this gamma ray monitoring system is unique, specially designed software was written and acceptance tested by Savannah River National Laboratory personnel. The software is a LabView-based application that serves as a unified interface for controlling

  9. Evaluation of a gamma monitor for survey of waste for shallow land burial

    International Nuclear Information System (INIS)

    Hoy, J.E.

    1978-12-01

    During an 8-month evaluation of the Gamma Waste Monitor, 54 reactor-area scrap casks and 8 shipments from the separations areas containing fission product activities were measured. It was concluded that a more accurate and detailed record of radionuclide burials can be obtained by using this monitor than by present methods of estimation. The monitor will significantly improve records and will provide a more reliable data base for evaluating long-term effects on the environment. Although the monitor can directly detect only gamma-emitting radionuclides, a method is proposed in this report for estimating the total radionuclide distribution by association with radionuclides that are detected. The monitor cannot assay transuranic waste and tritium. In many cases where the radionuclide emits two gamma rays of different energy, corrections for attenuation at other photon energies can be empirically derived from the spectrum. Complete details are included in the Appendix for operating the facility. Experimental data gathered during the evaluation period are contained in the body of this report

  10. Gamma-ray detectors for intelligent, hand-held radiation monitors

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1983-01-01

    Small radiation detectors based on HgI 2 , bismuth germanate (BGO), plastic, or NaI(Tl) detector materials were evaluated for use in small, lighweight radiation monitors. The two denser materials, HgI 2 and BGO, had poor resolution at low-energy and thus performed less well than NaI(Tl) in detecting low-energy gamma rays from bare, enriched uranium. The plastic scintillator, a Compton recoil detector, also performed less well at low gamma-ray energy. Two small NaI(Tl) detectors were suitable for detecting bare uranium and sheilded plutonium. One became part of a new lightweight hand-held monitor and the other found uses as a pole-mounted detector for monitoring hard-to-reach locations

  11. Requirements for the authorization of operation os a calibration laboratory of gamma-ray monitors

    International Nuclear Information System (INIS)

    Silva, Raimundo Dias da; Kibrit, Eduardo

    2011-01-01

    This paper describes the process for obtaining the authorization of operation of a laboratory designed to calibrate area and personal monitors with gamma radiation, by using a sealed Cs-137 source. The regulations of Comissao Nacional de Energia Nuclear (CNEN) are deeply analysed and discussed. The authorization for construction, the authorization for modification of items important to safety, the authorization for the acquisition and handling of radiation sources, the authorization for operating, and the authorization for withdrawal of operation of the laboratory are also discussed. The paper also describes the technical and managerial requirements necessary to operate a gamma radiation calibration laboratory in Brazil. . (author)

  12. Autonomous long-term gamma-spectrometric monitoring of submarine groundwater discharge trends in Hawaii

    International Nuclear Information System (INIS)

    Dulai, Henrietta; Waters, Ch.A.; Kennedy, Joseph; Kamenik, Jan; Academy of Sciences of the Czech Republic, Rez; Babinec, James; Jolly, James; Williamson, Mario

    2016-01-01

    We developed a fully autonomous underwater gamma-spectrometer for long-term coastal submarine groundwater discharge (SGD) monitoring. The instrument represents a significant improvement over previous submarine gamma-spectrometers in that it is very robust, has high sensitivity allowing high temporal resolution, and is completely autonomous. Here we describe the technical parameters of the new instrument as well as data collected over its 9-month deployment in Kiholo Bay, HI, USA. We also present methods to convert the measured activities to SGD rates. In Kiholo Bay, the derived SGD matched previous estimates but in addition it revealed previously undocumented short- and long-term patterns in SGD. (author)

  13. Continuous Monitoring of GAMMA Radiation Field in the Reactor RA Building

    International Nuclear Information System (INIS)

    Stalevski, T.

    2008-01-01

    This paper presents the system for continuos monitoring of gamma doze rate in the reactor RA building. Industrial (PC compatible) computer acquires analog signals from eight ionization chambers and eight analog signals from three BPH devices. Digital output interface is used for testing ionization chambers and BPH devices. Computer program for data analyzes and presentation is written in graphical programming language LabVIEW and enables monitoring of measured data in real time. Measured data can be monitored over local computer network, Internet and mobile devices using standard web browsers. (author)

  14. Development of a device for continuous automatic monitoring of consolidation of fresh concrete. Final report

    International Nuclear Information System (INIS)

    Lee, P.L.; Eggert, G.J.

    1978-01-01

    Quality of portland cement concrete can be increased if water/cement ratios are reduced; however, this increase is only achieved if concrete is adequately consolidated. This study was conducted to develop a device to permit continuous automatic monitoring of the degree of consolidation during pavement construction. A literature search identified several candidate techniques, the most feasible being a nuclear backscatter technique to measure concrete density. A prototype instrument was developed with a 500mCi source of Cesium (137) and a sodium iodide/photomultiplier sensing unit. The sensor head is located 1 inch (25.4 mm) above the concrete. It is moved back and forth across the width of the pavement by a traversing mechanism mounted to the back of a slip-form paver. Density is recorded on chart paper. The CMD (Consolidation Monitoring Device) is capable of sensing and displaying changes in density while traversing over the pavement surface at 17 fpm (0.086 m/s). It can duplicate core density measurements within a + or -2-1 pcf (+ or -36 kg cu m) confidence range

  15. Automatic Adjustments of a Trans-oesophageal Ultrasound Robot for Monitoring Intra-operative Catheters

    Science.gov (United States)

    Wang, Shuangyi; Housden, James; Singh, Davinder; Rhode, Kawal

    2017-12-01

    3D trans-oesophageal echocardiography (TOE) has become a powerful tool for monitoring intra-operative catheters used during cardiac procedures in recent years. However, the control of the TOE probe remains as a manual task and therefore the operator has to hold the probe for a long period of time and sometimes in a radiation environment. To solve this problem, an add-on robotic system has been developed for holding and manipulating a commercial TOE probe. This paper focuses on the application of making automatic adjustments to the probe pose in order to accurately monitor the moving catheters. The positioning strategy is divided into an initialization step based on a pre-planning method and a localized adjustments step based on the robotic differential kinematics and related image servoing techniques. Both steps are described in the paper along with simulation experiments performed to validate the concept. The results indicate an error less than 0.5 mm for the initialization step and an error less than 2 mm for the localized adjustments step. Compared to the much bigger live 3D image volume, it is concluded that the methods are promising. Future work will focus on evaluating the method in the real TOE scanning scenario.

  16. Automatic monitoring of isolation state in low-voltage distribution network

    Directory of Open Access Journals (Sweden)

    Людмила Олександрівна Добровольська

    2017-06-01

    Full Text Available The article discusses the possibility of using the proposed functional isolation monitoring circuit with an additional high-frequency signal of 3500 Hz, introduced into the power network, which allows real-time detection of isolation leakage current not exceeding 8,5 mA. To check the isolation state it was decided to control leakage currents. To do this it is proposed to use the current control device developed by the authors that provides measurement of the currents in the lines and used by consumers. The device makes it possible to determine the magnitude and locations of the unauthorized taking away the power and to transmit the data to the control station wirelessly. It is proposed to extend the functionality of the device by automatically measuring leakage currents when monitoring the isolation state if current exceeds the permissible limits. This can be achieved by introducing a current control device of frequency-dependent selective amplifier of sinusoidal leakage currents that solves the problem of frequency separation and allows the isolation state control without disconnecting users from the network. Early detection and removal of defects of isolation before they become interfacial short circuits and dead ground short circuits will prevent the occurrence of dangerous situations, increase the reliability and service life of electrical networks and ensure uninterrupted power supply of consumers with electricity

  17. Gamma Radiolytic Degradation of Heptachlor in Methanol and Monitoring of Degradation by HPLC

    International Nuclear Information System (INIS)

    Riaz, M.; Butt, S.B.

    2014-01-01

    Removal of known insecticide Heptachlor (HPTC) in methanol solution by gamma-rays under varied experimental conditions has been optimized. Air saturated solution of HPTC was irradiated at x-rays dose from 1 to 10 kGys. The extent of radiolytic degradation was monitored by reversed phase high performance liquid chromatography (HPLC) coupled with UV detector. At dose of 10 kGys gamma 98 % of HPTC was degraded. The degradation of HPTC occurs by CH/sub 3/O and CH/sub 2/OH radicals generated by methanol radiolysis. It is concluded that gamma-rays can remove Persistent Organic Pollutants (POPs) form environmental matrices. It can decrease the harmful properties of these POPs by their transformation into less resistant fragments to biological / natural elimination in the aquatic atmosphere. (author)

  18. SNM gamma-ray fingerprint monitor functional requirements and design specifications

    International Nuclear Information System (INIS)

    Bieber, A.M. Jr.; Kane, W.R.

    1994-07-01

    A number of DOE facilities need to perform confirmatory inventory measurements on items of special nuclear material (SNM). The DOE Office of Safeguards and Security (OSS) has tasked the Safeguards, Safety and Nonproliferation Division (SSN) of the Department of Advanced Technology at Brookhaven National Laboratory (BNL) to develop a high-resolution gamma-ray-spectroscopy-based instrument for performing confirmatory inventory measurements on such materials, a ''gamma-ray fingerprint monitor'' (GRFM). This document is a conceptual design for the SSN GRFM system. This conceptual design is based on previous experience with measurements of plutonium-bearing materials and comparison of gamma-ray spectrum features, not on actual tests of the procedures or hardware described. As a result, modifications may be necessary when actual prototype hardware and software are tested in realistic circumstances on actual materials of interest

  19. Definition of priority areas for monitoring of gamma radiation on the surroundings of the CDTN installations

    International Nuclear Information System (INIS)

    Chagas, Claudio Jose; Carvalho Filho, Carlos A.; Peixoto, Claudia Marques; Rodrigues, Paulo C. Horta; Augustin, Cristina Helena R. Rocha

    2013-01-01

    To demonstrate compliance with regulations and legal requirements, the Environmental Monitoring Program of the - Development Center of Nuclear Technology - PMA/CDTN was created in 1985. However, at that time, no data was available to represent the background - the natural level for the pre operational period in terms of Gamma radiation. Thus, the lowest value obtained among the sentinel point sites from the early period of the environmental monitoring was adopted as benchmark. As these measurements were performed by procedures and conditions other than that currently in use, this reference value may not correspond to reality. Therefore, it may not be appropriate to use it as background in assessing the possible environmental impact generated by the activities of the facilities. The goal of this study is to propose an area of geographic distribution for 12 monitoring points, outside the CDTN facilities, so that the real natural Gamma radiation levels can be accurately measured without the interference of the radioactivity levels originating from the institution, enabling the determination of the most representative values of the natural gamma radiation in the area. This survey of the natural radiation determination in the study area, with the use of modern equipment and the application of methodology taking into account historical data, as well the geological, geomorphological and geographical studies of the region, pointed to an average background value of 0.095μSv/h. This result, together with other studies, indicated a maximum range of 25m beyond the CDTN boundaries to distribute the monitoring points. (author)

  20. Automatic mental heath assistant : monitoring and measuring nonverbal behavior of the crew during long-term missions

    NARCIS (Netherlands)

    Voynarovskaya, N.; Gorbunov, R.D.; Barakova, E.I.; Rauterberg, G.W.M.; Barakova, E.I.; Ruyter, B.; Spink, A.

    2010-01-01

    This paper presents a method for monitoring the mental state of small isolated crews during long-term missions (such as space mission, polar expeditions, submarine crews, meteorological stations, and etc.) The research is done as a part of Automatic Mental Health Assistant (AMHA) project which aims

  1. Automatic monitoring of radial injection tracer tests using a novel multi-electrode resistivity system

    International Nuclear Information System (INIS)

    Ward, R.S.; Sen, M.A.; Williams, G.M.; Jackson, P.D.

    1990-01-01

    A radial injection tracer test has been carried out in an unconfined fluvial sand and gravel aquifer underlain by low permeability clay. Sodium chloride has been used as an electrolyte tracer and breakthrough has been monitored using a newly developed automatic resistivity system (RESCAN) incorporating six fully penetrating resistivity probes each having 80 electrodes spaced at 5 cm intervals along their length. Each electrode is individually addressable under computer control to either carry current or measure potential. Any four electrodes can be selected in the traditional Wenner configuration to measure formation resistivity. Rapid measurement of changes in resistivity allows a very detailed picture of tracer migration to be obtained. The resistivity probes were placed at 1 and 2 m radii from the central fully-screened tracer injection well along three limbs at 120 degrees. Resistivity measurements were compared with adjacent multi-level samplers. An 8 x 8 m grid of 140 surface electrodes centred on the central well was also installed. The resistivity profiles measured prior to tracer injection were used to infer lithology, particularly layering. Detailed breakthrough curves were obtained at 77 positions along each of the six probes and compared with adjacent multi-level sampler breakthrough curves. The results showed that the aquifer was extremely heterogeneous even on this small scale. Because the system operates automatically without the need to extract and analyse large numbers of water samples, it opens up the possibility of carrying out lots of small scale injection tests within a larger domain likely to be invaded by a tracer or pollution plume. Such detailed information for determining aquifer properties can provide the data set necessary for characterisation of the aquifer to predict dispersion parameters appropriate to the large scale. (Author) (6 refs., 9 figs., 2 tabs.)

  2. Automatic Monitoring System Design and Failure Probability Analysis for River Dikes on Steep Channel

    Science.gov (United States)

    Chang, Yin-Lung; Lin, Yi-Jun; Tung, Yeou-Koung

    2017-04-01

    The purposes of this study includes: (1) design an automatic monitoring system for river dike; and (2) develop a framework which enables the determination of dike failure probabilities for various failure modes during a rainstorm. The historical dike failure data collected in this study indicate that most dikes in Taiwan collapsed under the 20-years return period discharge, which means the probability of dike failure is much higher than that of overtopping. We installed the dike monitoring system on the Chiu-She Dike which located on the middle stream of Dajia River, Taiwan. The system includes: (1) vertical distributed pore water pressure sensors in front of and behind the dike; (2) Time Domain Reflectometry (TDR) to measure the displacement of dike; (3) wireless floating device to measure the scouring depth at the toe of dike; and (4) water level gauge. The monitoring system recorded the variation of pore pressure inside the Chiu-She Dike and the scouring depth during Typhoon Megi. The recorded data showed that the highest groundwater level insides the dike occurred 15 hours after the peak discharge. We developed a framework which accounts for the uncertainties from return period discharge, Manning's n, scouring depth, soil cohesion, and friction angle and enables the determination of dike failure probabilities for various failure modes such as overtopping, surface erosion, mass failure, toe sliding and overturning. The framework was applied to Chiu-She, Feng-Chou, and Ke-Chuang Dikes on Dajia River. The results indicate that the toe sliding or overturning has the highest probability than other failure modes. Furthermore, the overall failure probability (integrate different failure modes) reaches 50% under 10-years return period flood which agrees with the historical failure data for the study reaches.

  3. Calibration of an air monitor prototype for a radiation surveillance network based on gamma spectrometry

    International Nuclear Information System (INIS)

    Baeza, A.; Caballero, J.M.; Corbacho, J.Á.; Ontalba-Salamanca, M.Á.; Vasco, J.

    2014-01-01

    The objective of this work is to present the improvements that have been made in quasi-real-time air radioactivity concentration monitors which were initially based on overall activity determinations, by incorporating gamma spectrometry into the current prototype. To this end it was necessary to develop a careful efficiency calibration procedure for both the particulate and the gaseous fractions of the air being sampled. The work also reports the values of the minimum detectable activity calculated for different isotopes and acquisition times. - Highlights: • Deficiencies of a commercial air monitoring system are detailed. • Gamma spectrometry introduction is the basis of the new prototype. • Efficiency calibration procedure is described for aerosol and gaseous fractions. • MDA is evaluated for different isotopes and acquisition times

  4. Monitoring and Analysis of Environmental Gamma Dose Rate around Serpong Nuclear Complex

    Directory of Open Access Journals (Sweden)

    I.P. Susila

    2017-08-01

    Full Text Available An environmental radiation monitoring system that continuously measures gamma dose rate around nuclear facilities is an important tool to present dose rate information to the public or authorities for radiological protection during both normal operation and radiological accidents. We have developed such a system that consists of six GM-based device for monitoring the environmental dose rate around Serpong Nuclear Complex. It has operated since 2010. In this study, a description of the system and analysis of measured data are presented. Analysis of the data for the last five years shows that the average dose rate levels were between 84-99 nSv/h which are still lower than terrestrial gamma radiation levels at several other locations in Indonesia. Time series analysis of the monitoring data demonstrates a good agreement between an increase in environmental gamma dose rate and the presence of iodine and argon in the air by in situ measurement. This result indicates that system is also effective for an early warning system in the case of radiological emergency.

  5. Validation of gamma-ray detection techniques for safeguards monitoring at natural uranium conversion facilities

    Energy Technology Data Exchange (ETDEWEB)

    Dewji, S.A., E-mail: dewjisa@ornl.gov [Oak Ridge National Laboratory, 1 Bethel Valley Road, MS-6335, Oak Ridge, TN 37831-6335 (United States); Lee, D.L.; Croft, S. [Oak Ridge National Laboratory, 1 Bethel Valley Road, MS-6335, Oak Ridge, TN 37831-6335 (United States); Hertel, N.E. [Oak Ridge National Laboratory, 1 Bethel Valley Road, MS-6335, Oak Ridge, TN 37831-6335 (United States); Nuclear and Radiological Engineering Program, Georgia Institute of Technology, 770 State Street, Atlanta, GA 30332-0745 (United States); Chapman, J.A.; McElroy, R.D.; Cleveland, S. [Oak Ridge National Laboratory, 1 Bethel Valley Road, MS-6335, Oak Ridge, TN 37831-6335 (United States)

    2016-07-01

    Recent IAEA circulars and policy papers have sought to implement safeguards when any purified aqueous uranium solution or uranium oxides suitable for isotopic enrichment or fuel fabrication exists. Under the revised policy, IAEA Policy Paper 18, the starting point for nuclear material under safeguards was reinterpreted, suggesting that purified uranium compounds should be subject to safeguards procedures no later than the first point in the conversion process. In response to this technical need, a combination of simulation models and experimental measurements were employed to develop and validate concepts of nondestructive assay monitoring systems in a natural uranium conversion plant (NUCP). In particular, uranyl nitrate (UO{sub 2}(NO{sub 3}){sub 2}) solution exiting solvent extraction was identified as a key measurement point (KMP), where gamma-ray spectroscopy was selected as the process monitoring tool. The Uranyl Nitrate Calibration Loop Equipment (UNCLE) facility at Oak Ridge National Laboratory was employed to simulate the full-scale operating conditions of a purified uranium-bearing aqueous stream exiting the solvent extraction process in an NUCP. Nondestructive assay techniques using gamma-ray spectroscopy were evaluated to determine their viability as a technical means for drawing safeguards conclusions at NUCPs, and if the IAEA detection requirements of 1 significant quantity (SQ) can be met in a timely way. This work investigated gamma-ray signatures of uranyl nitrate circulating in the UNCLE facility and evaluated various gamma-ray detector sensitivities to uranyl nitrate. These detector validation activities include assessing detector responses to the uranyl nitrate gamma-ray signatures for spectrometers based on sodium iodide, lanthanum bromide, and high-purity germanium detectors. The results of measurements under static and dynamic operating conditions at concentrations ranging from 10–90 g U/L of natural uranyl nitrate are presented. A range of

  6. National automatic network of environmental radiological monitoring (RENAMORA); Red Nacional automatica de monitoreo radiologico ambiental (RENAMORA)

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez M, J.L.; Sanchez H, L. [CNSNS, Dr. Barragan 779, Col. Narvarte, 03020 Mexico D.F. (Mexico)]. e-mail: jlgonzalez@cnsns.gob.mx

    2003-07-01

    Inside the programs of Environmental Radiological Surveillance that it carries out the National Commission of Nuclear Security and Safeguards (CNSNS), it develops an National Automatic Network of Environmental Radiological Monitoring (RENAMORA), where it is carried out a registration of speed of environmental dose in continuous and simultaneous forms with the same moment of the measurement. This net allows to account with the meticulous and opportune information that will help to characterize, in dynamics form, the radiological conditions of diverse geographical zones of the country, including the sites that by normative require bigger surveillance, like its are the Laguna Verde Nuclear power station (CNLV), the Nuclear Center of Mexico (ININ) and the Radioactive waste storage center (CADER). This net is in its first development stage; three points inside the state of Veracruz, in the surroundings of the CNLV, already its are operating; the obtained data of rapidity of environmental dose are being stored in a database inside a primary data center located in the facilities of the CNSNS in Mexico city and its will be analyzed according to the project advances. At the moment, its are installing the first ten teams corresponding to the first phase of the RENAMORA (three stages); its are carried out operation tests, transmission, reception and administration of data. The obtained data will be interpreted, analyzed and inter compared to evaluate the risk levels to that it would be hold the population and to determine thresholds that allow to integrate the alarm systems that its had considered for emergency situations. (Author)

  7. Analysis on machine tool systems using spindle vibration monitoring for automatic tool changer

    Directory of Open Access Journals (Sweden)

    Shang-Liang Chen

    2015-12-01

    Full Text Available Recently, the intelligent systems of technology have become one of the major items in the development of machine tools. One crucial technology is the machinery status monitoring function, which is required for abnormal warnings and the improvement of cutting efficiency. During processing, the mobility act of the spindle unit determines the most frequent and important part such as automatic tool changer. The vibration detection system includes the development of hardware and software, such as vibration meter, signal acquisition card, data processing platform, and machine control program. Meanwhile, based on the difference between the mechanical configuration and the desired characteristics, it is difficult for a vibration detection system to directly choose the commercially available kits. For this reason, it was also selected as an item for self-development research, along with the exploration of a significant parametric study that is sufficient to represent the machine characteristics and states. However, we also launched the development of functional parts of the system simultaneously. Finally, we entered the conditions and the parameters generated from both the states and the characteristics into the developed system to verify its feasibility.

  8. Semi-Automatic Operational Service for Drought Monitoring and Forecasting in the Tuscany Region

    Directory of Open Access Journals (Sweden)

    Ramona Magno

    2018-02-01

    Full Text Available A drought-monitoring and forecasting system developed for the Tuscany region was improved in order to provide a semi-automatic, more detailed, timely and comprehensive operational service for decision making, water authorities, researchers and general stakeholders. Ground-based and satellite data from different sources (regional meteorological stations network, MODIS Terra satellite and CHIRPS/CRU precipitation datasets are integrated through an open-source, interoperable SDI (spatial data infrastructure based on PostgreSQL/PostGIS to produce vegetation and precipitation indices that allow following of the occurrence and evolution of a drought event. The SDI allows the dissemination of comprehensive, up-to-date and customizable information suitable for different end-users through different channels, from a web page and monthly bulletins, to interoperable web services, and a comprehensive climate service. The web services allow geospatial elaborations on the fly, and the geo-database can be increased with new input/output data to respond to specific requests or to increase the spatial resolution.

  9. CURRENT STATE ANALYSIS OF AUTOMATIC BLOCK SYSTEM DEVICES, METHODS OF ITS SERVICE AND MONITORING

    Directory of Open Access Journals (Sweden)

    A. M. Beznarytnyy

    2014-01-01

    Full Text Available Purpose. Development of formalized description of automatic block system of numerical code based on the analysis of characteristic failures of automatic block system and procedure of its maintenance. Methodology. For this research a theoretical and analytical methods have been used. Findings. Typical failures of the automatic block systems were analyzed, as well as basic reasons of failure occur were found out. It was determined that majority of failures occurs due to defects of the maintenance system. Advantages and disadvantages of the current service technology of automatic block system were analyzed. Works that can be automatized by means of technical diagnostics were found out. Formal description of the numerical code of automatic block system as a graph in the state space of the system was carried out. Originality. The state graph of the numerical code of automatic block system that takes into account gradual transition from the serviceable condition to the loss of efficiency was offered. That allows selecting diagnostic information according to attributes and increasing the effectiveness of recovery operations in the case of a malfunction. Practical value. The obtained results of analysis and proposed the state graph can be used as the basis for the development of new means of diagnosing devices for automatic block system, which in turn will improve the efficiency and service of automatic block system devices in general.

  10. Automatic storing of single gamma spectra on magnetic tape. Programs LONGO, DIRE; Automatizacion del almacenamiento en cinta magnetica de espectros gamma directos. Programas LONGO, DIRE

    Energy Technology Data Exchange (ETDEWEB)

    Los Arcos Merino, J M

    1978-07-01

    The program LONGO provides the block size and the block number in a binary file on magnetic tape. It has been applied to analyse the structure of the nine-track magnetic tapes storing single or coincidence gamma spectra files, recorded in octet form by a MULTI-8 minicomputer in the Nuclear Spectrometry Laboratory of J.E.N. Then the program DIRE has been written to transform the single gamma spectra into a new FASTRAND disk file, storing the information in-36 bit words. A copy of this file is obtained on magnetic tape and the single gamma spectra are then available by standard FORTRAN V reading sentences. (Author) 3 refs.

  11. Assessment of Geant4 Prompt-Gamma Emission Yields in the Context of Proton Therapy Monitoring

    Science.gov (United States)

    Pinto, Marco; Dauvergne, Denis; Freud, Nicolas; Krimmer, Jochen; Létang, Jean M.; Testa, Etienne

    2016-01-01

    Monte Carlo tools have been long used to assist the research and development of solutions for proton therapy monitoring. The present work focuses on the prompt-gamma emission yields by comparing experimental data with the outcomes of the current version of Geant4 using all applicable proton inelastic models. For the case in study and using the binary cascade model, it was found that Geant4 overestimates the prompt-gamma emission yields by 40.2 ± 0.3%, even though it predicts the prompt-gamma profile length of the experimental profile accurately. In addition, the default implementations of all proton inelastic models show an overestimation in the number of prompt gammas emitted. Finally, a set of built-in options and physically sound Geant4 source code changes have been tested in order to try to improve the discrepancy observed. A satisfactory agreement was found when using the QMD model with a wave packet width equal to 1.3 fm2. PMID:26858937

  12. In-situ high-resolution gamma-spectrometric survey of burial ground-monitoring wells

    International Nuclear Information System (INIS)

    Bowman, W.W.

    1981-09-01

    In situ high resolution gamma-ray spectrometry with an intrinsic germanium detector assembly of special design surveyed the burial ground monitoring wells to locate and identify gamma emitters that may have migrated from the burial trenches toward the water table. Gamma-ray spectra were acquired as a function of depth in each well and recorded on magnetic tape. These spectra were reduced by a series of computer programs to produce count rate versus depth profiles for natural and man-made activities. The original spectra and the profiles have been archived on magnetic tape for comparison with similar future surveys. Large amounts of man-made activities were observed in some of the burial trenches; however, below the trench bottoms, only very low but detectable amounts of 60 Co and 137 Cs were observed in eleven wells. The highest level of man-made gamma activity observed below the trench bottoms has a count rate roughly equal to that observed for uranium daughter activities which are natural to the subsoil

  13. Monitoring catalyst flow rate in a FCC cold pilot unity by gamma ray transmission measurements

    International Nuclear Information System (INIS)

    Brito, Marcio F.P.; Netto, Wilson F.S.; Miranda, Marcia V.F.E.S.; Junior, Isacc A.S.; Dantas, Carlos C.; Melo, Silvio B.; Lima, Emerson A.O.

    2013-01-01

    A model for monitoring catalyst mass flow in riser of Fluid Catalytic Cracking - FCC, pilot unity as a function of air flow and solid injection is proposed. The fluidized FCC- catalyst bed system is investigated in an experimental setup the Cold Pilot Unity - CPU by means of gamma ray transmission measurements. Riser in CPU simulates the reactor in FCC process. By automation control air flow is instrumentally measured in riser and the solid injection is manually controlled by valve adjusting. Keeping a constant solid injection, catalyst level at the return column was measured by gamma transmission for several air flow values in riser. The operational condition reached a steady state regime before given to setup a new air flow value. A calibration of catalyst level as a function of air flow in riser is calculated, therefore, a model for solid feed rate is derived. Recent published work evaluates solid concentration in riser of the CPU by means of gamma ray transmission, and a correlation with air velocity is obtained. In this work, the model for solid feed rate was further investigated by carrying out experiments to measure catalyst concentration at the same air flow values. These experiments lead to a model for monitoring catalyst flow in riser as function of solid feed rate and air flow. Simulation with random numbers produced with Matlab software allows to define validation criteria for the model parameters. (author)

  14. Automatic detection of clinical mastitis is improved by in-line monitoring of somatic cell count

    NARCIS (Netherlands)

    Kamphuis, C.; Sherlock, R.; Jago, J.; Mein, G.; Hogeveen, H.

    2008-01-01

    This study explored the potential value of in-line composite somatic cell count (ISCC) sensing as a sole criterion or in combination with quarter-based electrical conductivity (EC) of milk, for automatic detection of clinical mastitis (CM) during automatic milking. Data generated from a New Zealand

  15. Monitoring the sulfur content of coal streams by thermal-neutron-capture gamma-ray analysis

    International Nuclear Information System (INIS)

    Martin, J.W.; Hall, A.W.

    1976-07-01

    A theory was developed for evaluating a complex, prompt gamma ray spectrum to serve as the basis for an instrument to monitor continuously the sulfur content of tonnage streams of coal. Equations for the energies and intensities of prompt gamma rays emitted from 13 most significant elements in coal are combined into a single equation that defines the basic electronic design of the meter. The sulfur content of up to 10 tons per hour of coal was determined in pilot plant tests with a prototype meter. The precision of 0.04 percent sulfur substantiates the validity of the theory. In subsequent industrial plant tests the precision was determined to be a comparable 0.05 percent sulfur

  16. An improved, computer-based, on-line gamma monitor for plutonium anion exchange process control

    International Nuclear Information System (INIS)

    Pope, N.G.; Marsh, S.F.

    1987-06-01

    An improved, low-cost, computer-based system has replaced a previously developed on-line gamma monitor. Both instruments continuously profile uranium, plutonium, and americium in the nitrate anion exchange process used to recover and purify plutonium at the Los Alamos Plutonium Facility. The latest system incorporates a personal computer that provides full-feature multichannel analyzer (MCA) capabilities by means of a single-slot, plug-in integrated circuit board. In addition to controlling all MCA functions, the computer program continuously corrects for gain shift and performs all other data processing functions. This Plutonium Recovery Operations Gamma Ray Energy Spectrometer System (PROGRESS) provides on-line process operational data essential for efficient operation. By identifying abnormal conditions in real time, it allows operators to take corrective actions promptly. The decision-making capability of the computer will be of increasing value as we implement automated process-control functions in the future. 4 refs., 6 figs

  17. Environmental radiation monitoring: mobile gamma dose rate measurements along Mumbai-Hyderabad rail route and Hyderabad city roads

    International Nuclear Information System (INIS)

    Divkar, J.K.; Padmanabhan, N.; Chaudhury, Probal; Pradeepkumar, K.S.; Pujari, R.N.; Dogra, Santosh; Sharma, D.N.; Rajagopalan, S.; Srivastava, G.K.

    2005-01-01

    Environmental Radiation monitoring based on gamma dose rate logging on a mobile platform integrated with real time position from a Global Positioning System is an effective tool to acquire dose rate profile and generate radiological map of any geographical region. The microcontroller based dose rate data acquisition system capable of storing the acquired data and transferring to an attached laptop/PC and providing a graphical illustration of relative variations in gamma background can also be used for quick assessment of environmental radiological impact assessment. This paper describes the methodology and results of the environmental gamma dose rate monitoring surveys carried out: (i) on Mumbai-Hyderabad rail route with the systems installed in the trains guard's room and (ii) Hyderabad city roads with systems installed in a monitoring van. The results indicate significant difference in the gamma background measured along the rail route between Mumbai-Hyderabad and in the radiological map generated after the Hyderabad city survey. (author)

  18. Monitoring of mass flux of catalyst FCC in a Cold Pilot Unit by gamma radiation transmission

    International Nuclear Information System (INIS)

    Brito, Marcio Fernando Paixao de

    2014-01-01

    This paper proposes a model for monitoring the mass flow of catalyst FCC - Fluid Catalytic Cracking - in a CPU - Cold Pilot unit - due to the injection of air and solid by gamma radiation transmission. The CPU simplifies the process of FCC, which is represented by the catalyst cycle, and it was constructed of acrylic, so that the flow can be visualized. The CPU consists of riser separation chamber and return column, and simulates the riser reactor of the FCC process. The catalyst is injected into the column back to the base of the riser, an inclined tube, where the compressed air means that there fluidization along the riser. When the catalyst comes in the separation chamber, the solid phase is sent to the return column, and the gas phase exits the system through one of the four cyclones at the top of the separation chamber. The transmission gamma of measures will be made by means of three test sections that have source and detector shielded. Pressure drop in the riser measurements are made through three pressure gauges positioned on the riser. The source used was Am-241 gamma ray with energy of 60 keV, and detector used was a scintillator of NaI (Tl) of 2 x 2 . Measures the mass flow of catalyst are made by varying the seal of the catalyst, and density of solid in the riser because with the combination of these measures can determine the speed of the catalyst in the riser. The results show that the transmission gamma is a suitable technique for monitoring the flow of catalyst, flow model in CPU is annular, tomography third generation is more appropriate to study the CPU and the density variation in circulation in the CPU decreases linearly with increasing air flow. (author)

  19. Automation of the monitoring in real time of the absorbed dose rate in air due to the environmental gamma radiation in Cuba; Automatizacion del monitoreo en tiempo real de la tasa de dosis absorbida en aire debido a la radiacion gamma ambiental en Cuba

    Energy Technology Data Exchange (ETDEWEB)

    Dominguez L, O; Capote F, E; Carrazana G, J A; Manzano de Armas, J F; Alonso A, D; Prendes A, M; Zerquera, J T; Caveda R, C A [CPHR, Calle 20, No. 4113 e/41 y 47, Playa, La Habana, 11300, A.P. 6195 C.P. 10600 (Cuba); Kalberg, O [Swedish Radiation Protection Institute (SSI) (Sweden); Fabelo B, O; Montalvan E, A [CIAC, Camaguey (Cuba); Cartas A, H [CEAC, Cienfuegos (Cuba); Leyva F, J C [CISAT (Cuba)

    2006-07-01

    The Center of Protection and Hygiene of the Radiations (CPHR) like center rector of the National Net of Environmental Radiological Surveillance (RNVRA), it has strengthened their detection capacity and of answer before a situation of radiological emergency. The measurements of the absorbed dose rate in air due to the environmental gamma radiation in the main stations of the Net are obtained in real time and the CPHR receives the data coming from these posts at one time relatively short. To improve the operability of the RNVRA it was necessary to complete the facilities of existent monitoring using 4 automatic measurement stations with probes of gamma detection, implementing in this way a measurement system on real time. On the other hand the software were developed: GenironProbeFech, to obtain the data of the probes, DataMail for the shipment of the same ones by electronic mail and GammaRed that receives and processes the data in the rector center. (Author)

  20. Gamma-ray and neutron area monitoring system of linear IFMIF prototype accelerator building

    International Nuclear Information System (INIS)

    Takahashi, Hiroki; Kojima, Toshiyuki; Narita, Takahiro; Tsutsumi, Kazuyoshi; Maebara, Sunao; Sakaki, Hironao; Nishiyama, Koichi

    2013-01-01

    Highlights: • Area monitoring system and control system are needed for LIPAc radiation management. • To secure the radiation safety, these systems are linked with two kinds of data path. • Hardwired data paths are adopted to realize the fast transfer of interlock signals. • Dual LAN and shared memory are adopted to the reliable transfer of monitoring data. • Data transfers without unnecessary load are designed and configured for these systems. -- Abstract: The linear IFMIF prototype accelerator (LIPAc) produces deuteron beam with 1 MW power. Since huge number of neutrons occur from such a high power beam, therefore, it is important for the radiation management to design a high reliability area monitoring system for gamma-rays and neutrons. To obtain the valuable operation data of the high-power deuteron beam at LIPAc, it is important to link and record the beam operation data and the area monitoring data. We realize the reliable data transfer to provide the area monitoring data to the accelerator control system which needs a high reliability using the shared-memory data link method. This paper describes the area monitoring system in the LIPAc building and the data-link between this system and the LIPAc control system

  1. Automatic polymerase chain reaction product detection system for food safety monitoring using zinc finger protein fused to luciferase

    International Nuclear Information System (INIS)

    Yoshida, Wataru; Kezuka, Aki; Murakami, Yoshiyuki; Lee, Jinhee; Abe, Koichi; Motoki, Hiroaki; Matsuo, Takafumi; Shimura, Nobuaki; Noda, Mamoru; Igimi, Shizunobu; Ikebukuro, Kazunori

    2013-01-01

    Graphical abstract: -- Highlights: •Zif268 fused to luciferase was used for E. coli O157, Salmonella and coliform detection. •Artificial zinc finger protein fused to luciferase was constructed for Norovirus detection. •An analyzer that automatically detects PCR products by zinc finger protein fused to luciferase was developed. •Target pathogens were specifically detected by the automatic analyzer with zinc finger protein fused to luciferase. -- Abstract: An automatic polymerase chain reaction (PCR) product detection system for food safety monitoring using zinc finger (ZF) protein fused to luciferase was developed. ZF protein fused to luciferase specifically binds to target double stranded DNA sequence and has luciferase enzymatic activity. Therefore, PCR products that comprise ZF protein recognition sequence can be detected by measuring the luciferase activity of the fusion protein. We previously reported that PCR products from Legionella pneumophila and Escherichia coli (E. coli) O157 genomic DNA were detected by Zif268, a natural ZF protein, fused to luciferase. In this study, Zif268–luciferase was applied to detect the presence of Salmonella and coliforms. Moreover, an artificial zinc finger protein (B2) fused to luciferase was constructed for a Norovirus detection system. In the luciferase activity detection assay, several bound/free separation process is required. Therefore, an analyzer that automatically performed the bound/free separation process was developed to detect PCR products using the ZF–luciferase fusion protein. By means of the automatic analyzer with ZF–luciferase fusion protein, target pathogenic genomes were specifically detected in the presence of other pathogenic genomes. Moreover, we succeeded in the detection of 10 copies of E. coli BL21 without extraction of genomic DNA by the automatic analyzer and E. coli was detected with a logarithmic dependency in the range of 1.0 × 10 to 1.0 × 10 6 copies

  2. Automatic polymerase chain reaction product detection system for food safety monitoring using zinc finger protein fused to luciferase

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Wataru; Kezuka, Aki; Murakami, Yoshiyuki; Lee, Jinhee; Abe, Koichi [Department of Biotechnology and Life Science, Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei, Tokyo 184-8588 (Japan); Motoki, Hiroaki; Matsuo, Takafumi; Shimura, Nobuaki [System Instruments Co., Ltd., 776-2 Komiya-cho, Hachioji, Tokyo 192-0031 (Japan); Noda, Mamoru; Igimi, Shizunobu [Division of Biomedical Food Research, National Institute of Health Sciences, 1-18-1 Kamiyoga, Setagaya-ku, Tokyo 158-8501 (Japan); Ikebukuro, Kazunori, E-mail: ikebu@cc.tuat.ac.jp [Department of Biotechnology and Life Science, Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei, Tokyo 184-8588 (Japan)

    2013-11-01

    Graphical abstract: -- Highlights: •Zif268 fused to luciferase was used for E. coli O157, Salmonella and coliform detection. •Artificial zinc finger protein fused to luciferase was constructed for Norovirus detection. •An analyzer that automatically detects PCR products by zinc finger protein fused to luciferase was developed. •Target pathogens were specifically detected by the automatic analyzer with zinc finger protein fused to luciferase. -- Abstract: An automatic polymerase chain reaction (PCR) product detection system for food safety monitoring using zinc finger (ZF) protein fused to luciferase was developed. ZF protein fused to luciferase specifically binds to target double stranded DNA sequence and has luciferase enzymatic activity. Therefore, PCR products that comprise ZF protein recognition sequence can be detected by measuring the luciferase activity of the fusion protein. We previously reported that PCR products from Legionella pneumophila and Escherichia coli (E. coli) O157 genomic DNA were detected by Zif268, a natural ZF protein, fused to luciferase. In this study, Zif268–luciferase was applied to detect the presence of Salmonella and coliforms. Moreover, an artificial zinc finger protein (B2) fused to luciferase was constructed for a Norovirus detection system. In the luciferase activity detection assay, several bound/free separation process is required. Therefore, an analyzer that automatically performed the bound/free separation process was developed to detect PCR products using the ZF–luciferase fusion protein. By means of the automatic analyzer with ZF–luciferase fusion protein, target pathogenic genomes were specifically detected in the presence of other pathogenic genomes. Moreover, we succeeded in the detection of 10 copies of E. coli BL21 without extraction of genomic DNA by the automatic analyzer and E. coli was detected with a logarithmic dependency in the range of 1.0 × 10 to 1.0 × 10{sup 6} copies.

  3. Automatic national network of radiation environmental monitoring in Mexico; Red nacional automatica de monitoreo radiologico ambiental en Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Aguirre, Jaime; Delgado, Jose L.; Lopez, Manuel; Zertuche, Jorge V., E-mail: jaguirre@cnsns.gob.mx, E-mail: jldelgado@cnsns.gob.mx, E-mail: mlopez@cnsns.gob.mx, E-mail: jorge.zertuche@cnsns.gob.mx [Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS), D.F. (Mexico). Direccion de Vigilancia Radiologica

    2013-07-01

    The Direccion de Vigilancia Radiologica (DVR) of the Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS) de Mexico, performs several function for environmental radiation monitoring. One of these functions is the permanent monitoring of the environmental gamma radiation. For this, it implemented the Red Nacional Automatica de Monitoreo Radiologico Ambiental (RENAMORA) - the National Automated Network for Environmental Radiation Monitoring,which currently comprises 60 detector probes for gamma radiation which with a programmable system that includes information technologies, data transmission and software can send the information in real time to a primary center of data located in the facilities of CNSNS. - When the data are received, the system performs the verification and extraction of the information organized in Tables and charts, and generates a report of environmental gamma radiation dose rate average for each of the probes and for each period of time determined bu CNSNS. The RENAMORA covers the main cities and allows to establish the bases of almost the entire country, as well as to warn about abnormal situations caused by incidents or natural events generated by human activities inside or outside the country which involves radioactive materials; paying special attention to main radiological sites, such as the surroundings of the Laguna Verde Nuclear Power Plants, research centers and the radioactive waste disposal sites.

  4. On-line gamma spectroscopy measuring station for cover gas monitoring at KNK II

    International Nuclear Information System (INIS)

    Hoffmann, G.; Letz, K.D.

    1980-02-01

    An automated Ge-γ-spectrometer was developed for cover gas monitoring at KNK II which, by the gamma spectra measured, is to allow the following statements to be made on fuel cladding failure: Type, size, variation with time and subsequent development of the failure. In this report the hardware and software will be explained. Besides, an instruction manual was written for the measuring station, which allows to operate it without detailed knowledge of the manuals for the individual hardware components. (orig.) 891 HP/orig. 892 MKO [de

  5. Interpretation of the radioactive background observed in the OSO-7 gamma ray monitor

    International Nuclear Information System (INIS)

    Dyer, C.S.

    1975-01-01

    Application of a spallation activation calculation to the OSO-7 gamma-ray monitor background shows that major line features and about 30% of the continuum can be understood as activation of the central detector crystal by trapped protons. Weaker line features arise from activation of materials unshielded by the anticoincidence cup, while the remaining continuum and annihilation line would seem to come largely continuum and annihilation line would seem to come largely from electron-photon cascades originating in the spacecraft. (orig.) [de

  6. Performance and scientific results of the BeppoSAX Gamma-Ray Burst Monitor

    International Nuclear Information System (INIS)

    Feroci, M.; Costa, E.; Cinti, M. N.; Frontera, F.; Dal Fiume, D.; Nicastro, L.; Orlandini, M.; Palazzi, E.; Amati, L.; Zavattini, G.; Coletta, A.

    1998-01-01

    The Italian-Dutch satellite for X-ray Astronomy BeppoSAX is successfully operating on a 600 km equatorial orbit since May 1996. We present here the in-flight performance of the Gamma Ray Burst Monitor (GRBM) experiment during its first year of operation. The GRBM is performing very well, providing an amount of data on GRBs, some of which confirmed by other experiments onboard satellites. It also joined the 3rd Interplanetary Network as a new near-earth node. Important results have been obtained for GRBs (e.g. GRB970228) simultaneously detected in the Wide Field Cameras onboard the same satellite

  7. Automatic Sample Changing System for Gamma-Ray Spectrometry; Changeur Automatique d'Echantillons Pourla Spectrometrie Gamma; Avtomaticheskaya sistema dlya smeny obraztsov pri gamma-spektrometrii; Cambiador Automatico de Muestras para Espectroscopia Gamma

    Energy Technology Data Exchange (ETDEWEB)

    Lamson, K. C.; Sesko, W. J.; Nicholson, G. C. [Northeastern Radiological Health Laboratory, Winchester, MA (United States)

    1965-10-15

    The detection of gamma-emitting radionuclides at environmental levels in biological media requires that the sensitivity of the counting system be high. To accumulate sufficiently precise data, it is often necessary to count samples for long periods of time - from one to several hours. The most efficient utilization of expensive low-background gamma-ray spectrometric counting equipment requires that it be operated on a continuous basis. This necessitates either the continuous presence of personnel or a completely automated system, including the changing of samples and recording of data. The purpose of this paper is to describe the automated gamma-ray spectrometry counting system designed, built and in use at the Northeastern Radiological Health Laboratory, Winchester, Massachusetts. The sample changing unit was designed to operate in conjunction with a large steel shield, any commercial unit with a front opening door being readily adaptable for this purpose. The changer is equipped to handle a variety of samples including biological and medical types. The unit consists of a revolving tray with a capacity for sixteen samples, an indexing system for positioning the samples, a mechanical arm with an attached electromagnet for inserting and removing the samples from the shield, and a lever for opening and closing the shield door. The changer has been completely integrated with a multichannel analyser with the provision of safety features to interrupt the cycle in case of malfunction at any step. After a preset counting period, the data are punched onto paper tape and processed by an IBM. 1620 computer. The first model of the sample changer, for which a patent is pending, has been in operation at the Northeastern Radiological Health Laboratory for about one year. During that time, it has been used extensively and has proven completely satisfactory. The total cost of the unit, including labour, was less than $ 2000. (author) [French] GAMMAPour deceler les radionucleides

  8. Radioactivity Monitoring System for TRIGA 2000 Reactor Water Tank with On-Line Gamma Spectrometer

    International Nuclear Information System (INIS)

    Prasetyo Basuki; Sudjatmi KA

    2009-01-01

    One of the requirements in radiological safety in the operating condition of research reactor are the absence of radionuclide from fission product released to reactor cooling water and environment. Early detection of fission product that released from fuel element can be done by monitoring radioactivity level on primary cooling water.Reactor cooling water can be used as an important indicator in detecting radioactivity level of material fission product, when the leakage occurs. Therefore, it needs to build a monitoring system for measuring radioactivity level of cooling water directly and simple. The idea of this system is counting radioactivity water flow from reactor tank to the marinelli cube that attached to the HPGe detector on gamma spectrometer. Cooling water from tank aimed on plastic pipe to the marinelli cube. Water flows in gravitational driven to the marinelli cube, with volume flow rate 5.1 liters/minute in the inlet and 2.2 liters/minute in output. (author)

  9. Environmental monitoring system based on airborne gamma ray spectrometry developed at Geoinstitut Beograd

    International Nuclear Information System (INIS)

    Milojevic, M.; Strumberger, V.

    1997-01-01

    The continuous hazard of nuclear reactor failures, which may exceed in consequences that of the Chernobyl accident on 26 April 1986, makes it imperative for us to develop and introduce soil, water and air contamination control systems to protect the environment. A most efficient means of the contamination control at the artificial radioactive radiation sources is the complex MONITORING SYSTEM controlled from a centre by competent and recognised experts. Such systems have been used for years now many western world countries (USA, Canada, Sweden, etc.). The modest purpose of this paper is at least to leave a trace of the efforts, both individual and of the institute, made in developing a component of the monitoring system - airborne gamma-ray contamination control, which in western systems is a principal technique of remote detection. (author)

  10. A new code for spectrometric analysis for environmental radiological surveillance on monitors focused on gamma radioactivity on aerosols

    Energy Technology Data Exchange (ETDEWEB)

    De Blas, Alfredo; Tapia, Carlos; Riego, Albert; Garcia, Roger; Dies, Javier; Diaz, Pedro [Nuclear Engineering Research Group, Departament of Physics and Nuclear Engineering, Technical University of Catalonia, Barcelona (Spain); Toral, Juan [Raditel Serveis, Tarragona (Spain); Batalla, Enric [Radiological Activities Corrdination Service - SCAR, Generalitat de Catalunya. Barcelona (Spain)

    2015-07-01

    pGamma is a code developed by the NERG group of the Technical University of Catalonia - Barcelona Tech for the analysis of gamma spectra generated by the Equipment for the Continuous Measurement and Identification of Gamma Radioactivity on Aerosols with Paper Filter developed for our group and Raditel Servies company. Nowadays the code is in the process of adaptation for the monitors of the Environmental Radiological Surveillance Network of the Local Government of Catalonia (Generalitat of Catalonia), Spain. The code is a Spectrum Analysis System, it identifies the gamma emitters on the spectrum, determines its Concentration of Activity, generates alarms depending on the Activity of the emitters and generates a report. The Spectrum Analysis System includes a library with emitters of interest, NORM and artificial. The code is being used on the three stations with the aerosol monitor of the Network (Asco and Vandellos, near both Nuclear Power Plants and Barcelona). (authors)

  11. Progress in Gamma Ray Measurement Information Barriers for Nuclear Material Transparency Monitoring

    International Nuclear Information System (INIS)

    Wolford, J.K.; White, G.K.

    2000-01-01

    Negotiations between technical representatives of the US and the Russian Federation in support of several pending nuclear arms and nuclear material control agreements must take account of the need for assurances against the release of sensitive information. Most of these agreements involve storing nuclear material and in some cases nuclear components from stockpile weapons in specially designed containers. Strategies for monitoring the agreements typically include measuring neutron and gamma radiation from the controlled items to verify declared attributes of plutonium or highly enriched uranium. If accurate enough to be useful, these measurements will contain information about the design of the component being monitored, information considered sensitive by one or both parties to the agreement. Safeguards have evolved to prevent disclosure of this information during inspections. These measures combine hardware, software, and procedural measures to contain the sensitive data, presenting only the results needed for verification. Custom features preserve data security and guard against disclosure in case of failure. This paper summarizes the general problem and discusses currently developing solutions for a high resolution gamma ray detection system. It argues for the simplest possible implementation of several key system components

  12. Development of an on-line tritium monitor with gamma-ray rejection and energy discrimination

    International Nuclear Information System (INIS)

    Cox, S.A.; Yule, T.J.; Bennett, E.F.

    1981-01-01

    With the prospect of large fusion facilities coming on-line in the not-too-distant future, it is becoming increasingly important that an on-line tritium-monitoring system be developed which is capable of detecting small amounts of released tritium. Since tritium oxide is some 400 times as hazardous as elemental tritium, it is necessary to distinguish between the two in order to properly evaluate the hazard. Presently available on-line instrumentation has marginal sensitivity, is unable to distinguish between the two forms of tritium, and has poor discrimination against background gamma radiation and air activation products. The objective of our program is to develop a monitoring system with the capability of distinguishing between the two forms of tritium, detecting tritium with a sensitivity of a fraction of an MPC/sub a/ (1 MPC/sub a/ = 5. x 10 - 6 Ci/M 3 ) for the oxide, and discriminating against gamma activity and airborne activity other than tritium

  13. A microprocessor based area monitor system for neutron and gamma radiation

    International Nuclear Information System (INIS)

    Wilhelm, R.; Heusser, G.

    1980-01-01

    The conventional electronics of the area monitors at the MPI-Heidelberg accelerators have been replaced by a microprocessor system consisting of individual detector-microprocessors and a central microcomputer. The detector microprocessors convert the count rates of BF3 and GM counter tubes into dose rates and control three different radiation thresholds (failure, low and high level). Different warning signals are operated directly by the detector processors, whereas the dose rates are transferred to the central microcomputer. Here the data are processed for recording on tape and displaying on TV monitors. The detector as well as the central processors have been developed on the basis of a 16-bit microprocessor. In the control rooms the dose rates of the individual monitors are displayed and on an indicator board showing the different locations, the high radiation level and the state of the doors (open, locked, and closed, locked but open) are sianaled by different LED. If a high radiation threshold is surpassed, the doors adjacent to that area can be locked either by switches on the indicator board or automatically. Within the experimental area, the low and high radiation level is indicated by acoustic and light signals. The whole concept permits keeping the absorbed doses of the personnel as low as possible without affecting the flexibility of the experimental operations. The independence of the microprocessor driven area monitors guarantees a high reliability. Compared to conventional electronics the advantages of the system are its reliability and cost. (Author)

  14. A multiparametric automatic method to monitor long-term reproducibility in digital mammography: results from a regional screening programme.

    Science.gov (United States)

    Gennaro, G; Ballaminut, A; Contento, G

    2017-09-01

    This study aims to illustrate a multiparametric automatic method for monitoring long-term reproducibility of digital mammography systems, and its application on a large scale. Twenty-five digital mammography systems employed within a regional screening programme were controlled weekly using the same type of phantom, whose images were analysed by an automatic software tool. To assess system reproducibility levels, 15 image quality indices (IQIs) were extracted and compared with the corresponding indices previously determined by a baseline procedure. The coefficients of variation (COVs) of the IQIs were used to assess the overall variability. A total of 2553 phantom images were collected from the 25 digital mammography systems from March 2013 to December 2014. Most of the systems showed excellent image quality reproducibility over the surveillance interval, with mean variability below 5%. Variability of each IQI was 5%, with the exception of one index associated with the smallest phantom objects (0.25 mm), which was below 10%. The method applied for reproducibility tests-multi-detail phantoms, cloud automatic software tool to measure multiple image quality indices and statistical process control-was proven to be effective and applicable on a large scale and to any type of digital mammography system. • Reproducibility of mammography image quality should be monitored by appropriate quality controls. • Use of automatic software tools allows image quality evaluation by multiple indices. • System reproducibility can be assessed comparing current index value with baseline data. • Overall system reproducibility of modern digital mammography systems is excellent. • The method proposed and applied is cost-effective and easily scalable.

  15. Development of a portable monitor for detecting gamma radiation and X-rays

    International Nuclear Information System (INIS)

    Silva Neto, Paulo J. da; Lira, Carlos A.B. de O.; Oliveira, Arno H. de

    2011-01-01

    There are several ways to prevent individuals from receiving excessive or unnecessary doses of radiation, and area monitoring contributes to the radiation protection in the assessment whether these means are really efficient. The area monitoring is used to give an indication of radiation levels in certain locations. Using this method, one can estimate the dose received by staff occupying a particular area for a certain period of time. Hence, the purpose of this work was the construction of a portable monitor, consisting of an ionization chamber, with a volume of approximately 517 cc and built from tissue-equivalent material, and of its associated electronics. Radiation measurements of gamma and X-rays beams were then possible. The results showed a linear response of the monitor for different dose rates. The stability test of the response also showed a good reproducibility within ± 1%. A low energy dependence for energies between 16 - 200keV was observed, and complied well with the IEC 60846 standard. However, for the energy range 200 - 1250keV, the discrepancies to the IEC standard are considerable, so that the interposition of filters is necessary and may improve the energy response curve to within acceptable limits. (author)

  16. Environmental gamma dose rate monitoring along Mumbai-Pune route using environmental radiation monitor with navigational aid

    International Nuclear Information System (INIS)

    Padmanabhan, N.; Kale, M.S.; Raman, N.; Krishnamachari, G.; Harikumar, M.; Sharma, D.N.; Mehta, S.K.

    1997-01-01

    A continuous environmental radiation monitor with navigational aid (ERMNA) for mapping natural gamma radiation background on country wide scale by deployment in railway coaches, has been designed. The system makes use of Indian railway network which is one of the widest network of railways in the world covering nearly complete length and breadth of the country. The system uses an energy compensated (within ± 30%) GN detectors for measurement of environmental dose rate due to natural background, a global positioning system (GPS) for on-line acquisition of positional co-ordinates (longitude and latitude) and an 8085 based data acquisition and processing unit. This system is deployed in guard's cabin of a train. The dose rate data tagged with positional co-ordinates and collected by the system during train journey is down loaded into a Lap Top PC for storage, analysis and graphical representation. The system has been used for background monitoring between Mumbai and Pune. The dose rates recorded over a period of three months ranging from November 1996 to February 1997 along the route show no change in the values which vary from 4 μr/h to 6 μR/h along the route. It drops down to <3 μR/h within tunnels en route. (author)

  17. Self-powered detector probes for electron and gamma-ray beam monitoring in high-power industrial accelerators

    International Nuclear Information System (INIS)

    Lone, M.A.

    1992-08-01

    A self-powered detector (SPD) is a simple passive device that consists of a coaxial probe with a metallic outer sleeve, a mineral oxide insulating layer, and a metallic inner core. SPDs are used in nuclear reactors for monitoring neutron and gamma ray fields. Responses of various SPDs to electron and gamma ray beams from industrial accelerators were investigated with Monte Carlo simulations. By judicious choice of transmission filters, threshold SPD probes were investigated for on-line monitoring of the beam energy spectrum of the high-power IMPELA industrial electron accelerator. (Author) (14 figs, 16 refs.)

  18. TRIPLICATE SODIUM IODIDE GAMMA RAY MONITORS FOR THE SMALL COLUMN ION EXCHANGE PROGRAM

    Energy Technology Data Exchange (ETDEWEB)

    Couture, A.

    2011-09-20

    This technical report contains recommendations from the Analytical Development (AD) organization of the Savannah River National Laboratory (SRNL) for a system of triplicate Sodium Iodide (NaI) detectors to be used to monitor Cesium-137 ({sup 137}Cs) content of the Decontaminated Salt Solution (DSS) output of the Small Column Ion Exchange (SCIX) process. These detectors need to be gain stabilized with respect to temperature shifts since they will be installed on top of Tank 41 at the Savannah River Site (SRS). This will be accomplished using NaI crystals doped with the alpha-emitting isotope, Americium-241({sup 241}Am). Two energy regions of the detector output will be monitored using single-channel analyzers (SCAs), the {sup 137}Cs full-energy {gamma}-ray peak and the {sup 241}Am alpha peak. The count rate in the gamma peak region will be proportional to the {sup 137}Cs content in the DSS output. The constant rate of alpha decay in the NaI crystal will be monitored and used as feedback to adjust the high voltage supply to the detector in response to temperature variation. An analysis of theoretical {sup 137}Cs breakthrough curves was used to estimate the gamma activity expected in the DSS output during a single iteration of the process. Count rates arising from the DSS and background sources were predicted using Microshield modeling software. The current plan for shielding the detectors within an enclosure with four-inch thick steel walls should allow the detectors to operate with the sensitivity required to perform these measurements. Calibration, testing, and maintenance requirements for the detector system are outlined as well. The purpose of SCIX is to remove and concentrate high-level radioisotopes from SRS salt waste resulting in two waste streams. The concentrated high-level waste containing {sup 137}Cs will be sent to the Defense Waste Processing Facility (DWPF) for vitrification and the low-level DSS will be sent to the Saltstone Production Facility (SPF

  19. Fermi/GAMMA-RAY BURST MONITOR OBSERVATIONS OF SGR J0501+4516 BURSTS

    International Nuclear Information System (INIS)

    Lin Lin; Zhang Shuangnan; Kouveliotou, Chryssa; Baring, Matthew G.; Van der Horst, Alexander J.; Finger, Mark H.; Guiriec, Sylvain; Preece, Robert; Chaplin, Vandiver; Bhat, Narayan; Woods, Peter M.; Goegues, Ersin; Kaneko, Yuki; Scargle, Jeffrey; Granot, Jonathan; Von Kienlin, Andreas; Watts, Anna L.; Wijers, Ralph A. M. J.; Gehrels, Neil; Harding, Alice

    2011-01-01

    We present our temporal and spectral analyses of 29 bursts from SGR J0501+4516, detected with the gamma-ray burst monitor on board the Fermi Gamma-ray Space Telescope during 13 days of the source's activation in 2008 (August 22- September 3). We find that the T 90 durations of the bursts can be fit with a log-normal distribution with a mean value of ∼123 ms. We also estimate for the first time event durations of soft gamma repeater (SGR) bursts in photon space (i.e., using their deconvolved spectra) and find that these are very similar to the T 90 values estimated in count space (following a log-normal distribution with a mean value of ∼124 ms). We fit the time-integrated spectra for each burst and the time-resolved spectra of the five brightest bursts with several models. We find that a single power law with an exponential cutoff model fits all 29 bursts well, while 18 of the events can also be fit with two blackbody functions. We expand on the physical interpretation of these two models and we compare their parameters and discuss their evolution. We show that the time-integrated and time-resolved spectra reveal that E peak decreases with energy flux (and fluence) to a minimum of ∼30 keV at F = 8.7 x 10 -6 erg cm -2 s -1 , increasing steadily afterward. Two more sources exhibit a similar trend: SGRs J1550-5418 and 1806-20. The isotropic luminosity, L iso , corresponding to these flux values is roughly similar for all sources (0.4-1.5 x 10 40 erg s -1 ).

  20. Critical review of gamma spectrometry detection approaches for in-plant surface deposition monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Gregorich, Carola [Nuclear Fuels and Chemistry at the Electric Power Research Institute, Palo Alto, CA 94304, (United States)

    2015-07-01

    Surface deposition of activated corrosion product on oxide layers of light-water reactor primary system components is the primary source for ex-core radiation fields and personnel radiation exposure. Understanding the deposition mechanism and what factors influence the deposition and release behaviors are crucial for developing effective radiation field reduction measures. One of the available tools to assess the surface deposition is in-plant gamma spectrometry, which has been performed for several decades using either sodium iodide (NaI) or high-purity germanium (HPGe) detectors. Lately, the much more mobile cadmium-zinc-telluride (CZT) detectors are increasingly employed by stations because of their ease in use and handling. However, all of these gamma detectors face the same challenges; namely large-geometry samples of inconsistent sample compositions and sometimes gaps in the information necessary to establish proper efficiency calibrations. This paper reviews current measurements and efficiency calibration approaches taken in the industry. The validity of the measurement results and the feasibility of the data's use in understanding source term behavior is examined. Suggestions are made for the development of a more robust deposit characterization and radiation field monitoring program. (authors)

  1. Monitoring of processes with gamma-rays of neutron capture and short-living radionuclides

    International Nuclear Information System (INIS)

    Aripov, G.A.; Kurbanov, B.I.; Allamuratova, G.

    2004-01-01

    Element content is a fundamental parameter of a substance, on which all its properties, and also character of physical, chemical, biological, technological and ecological processes depend. Therefore monitoring of element content (in the course of technological process - on line; in natural conditions - in site; or in living organisms - in vivo) becomes necessary for investigation of aforementioned processes. This problem can be successfully solved by using the methods of prompt gamma activation analysis (PGAA) and instrumental neutron activation analysis (INAA) on short-living radionuclides. These methods don't depend on type of substance (biological, geological, technological etc.), since the content is determined by gamma radiation of nuclei, and allows to meet such a serious requirement like the necessity of achieving minimal irradiation of the object and its minimal residual activity. In this work minimal determinable concentrations of various elements are estimated (based on experimental data) by the method of PGAA using radionuclide 252 Cf - source of neutrons with the yield of the oil of 10 8 neutron/sec on the experimental device with preliminary focusing of neutrons /1/, and also data of determination of elements by their isotopes with maximum time efficiency /2,3/ by the method of INAA. (author)

  2. Online fault diagnostics and testing of area gamma radiation monitor using wireless network

    Science.gov (United States)

    Reddy, Padi Srinivas; Kumar, R. Amudhu Ramesh; Mathews, M. Geo; Amarendra, G.

    2017-07-01

    Periodical surveillance, checking, testing, and calibration of the installed Area Gamma Radiation Monitors (AGRM) in the nuclear plants are mandatory. The functionality of AGRM counting electronics and Geiger-Muller (GM) tube is to be monitored periodically. The present paper describes the development of online electronic calibration and testing of the GM tube from the control room. Two electronic circuits were developed, one for AGRM electronic test and another for AGRM detector test. A dedicated radiation data acquisition system was developed using an open platform communication server and data acquisition software. The Modbus RTU protocol on ZigBee based wireless communication was used for online monitoring and testing. The AGRM electronic test helps to carry out the three-point electronic calibration and verification of accuracy. The AGRM detector test is used to verify the GM threshold voltage and the plateau slope of the GM tube in-situ. The real-time trend graphs generated during these tests clearly identified the state of health of AGRM electronics and GM tube on go/no-go basis. This method reduces the radiation exposures received by the maintenance crew and facilitates quick testing with minimum downtime of the instrument.

  3. Large-volume and room-temperature gamma spectrometer for environmental radiation monitoring

    Directory of Open Access Journals (Sweden)

    Romain Coulon

    2017-10-01

    Full Text Available The use of a room-temperature gamma spectrometer is an issue in environmental radiation monitoring. To monitor radionuclides released around a nuclear power plant, suitable instruments giving fast and reliable information are required. High-pressure xenon (HPXe chambers have range of resolution and efficiency equivalent to those of other medium resolution detectors such as those using NaI(Tl, CdZnTe, and LaBr3:Ce. An HPXe chamber could be a cost-effective alternative, assuming temperature stability and reliability. The CEA LIST actively studied and developed HPXe-based technology applied for environmental monitoring. Xenon purification and conditioning was performed. The design of a 4-L HPXe detector was performed to minimize the detector capacitance and the required power supply. Simulations were done with the MCNPX2.7 particle transport code to estimate the intrinsic efficiency of the HPXe detector. A behavioral study dealing with ballistic deficits and electronic noise will be utilized to provide perspective for further analysis.

  4. Radioactivity analysis of sounai region by gamma spectrometry and radiation monitoring network

    International Nuclear Information System (INIS)

    El-Mongy, S.A.; Abd El-Aziz, N.; El-Tahawy, M.S.; Morsy, S.

    2000-01-01

    Levels of natural and man-made radioactivity in soil and plant of southern sinai region are investigated by using Gamma- spectrometric analysis. The found average concentrations of 2 26Ra ( 2 38U) series, 2 32Th series and 4 0K are 20.2, 17.0 and 378.8 Bq/Kg respectively. The fall out 1 37Cs is the only man-made radionuclide detected with concentrations not exceed 3 Bq/Kg (dry weight) in both soil and plant samples. The effective dose rate equivalent are 106, 129, 114 and 104 n Sv/h for El-Tour, Sharm El-Shaik, Nwuiba and Taba as detected by the corresponding stations of the national radiation monitoring network (NRMN) respectively. The radium equivalent (Req) and absorbed dose rate resulted due to the natural radionuclides in soil are also calculated and given

  5. The development of the prompt system of gamma radiation monitoring in FR Yugoslavia

    International Nuclear Information System (INIS)

    Orlic, M.; Pavlovic, R.; Pavlovic, S.

    1996-01-01

    The needs for and characteriztics of the prompt system of gamma radiation monitoring are analyzed. The basic structure of the new system, based on the PC computer is presented. The system consists of the central unit and a number of field stations connected via telephone lines. GM counter is used as a detector. The software is written in visual basic. The system is capable of performing a variety of tasks: dose rate measurement (analogue and digital), graphical presentation of the results in the given period of time, data base formation and management, data transmission and preparing reports. The basic characteriztics of hardware and software of the system, performance specifications and future plans are presented in this paper. (author)

  6. Development of gamma probe technique for monitoring rooting pattern of pearl millet under field conditions

    International Nuclear Information System (INIS)

    Vittal, K.P.R.; Subbiah, B.V.

    1982-01-01

    For the root distribution studies, methods are not available to measure the growth in situ and in toto under field conditions without destroying the plants. A non-destructive method was developed for measuring the gamma activity in root using a probe that was administered through the stem. Five isotopes viz. 86 Rb, 134 Cs, 59 Fe, 65 Zn and 54 Mn tested, were found to represent almost similar rooting pattern for pearl millet from flowering to harvesting stages. Among these isotopes 59 Fe was found to be suitable for field use. This method also enabled to successfully monitor the root activity over time and avoided the sampling errors. Since laboratory processing of samples was eliminated, the process of measurement was hastened. (author)

  7. An automatic gain matching method for {gamma}-ray spectra obtained with a multi-detector array

    Energy Technology Data Exchange (ETDEWEB)

    Pattabiraman, N.S.; Chintalapudi, S.N.; Ghugre, S.S. E-mail: ssg@alpha.iuc.res.in

    2004-07-01

    The increasing size of data sets from large multi-detector arrays makes the traditional approach to the pre-evaluation of the data difficult and time consuming. The pre-sorting involves detection and correction of the observed on-line drifts followed by calibration of the raw data. A new method for automatic detection and correction of these instrumental drifts is presented. An application of this method to the data acquired using a multi-Clover array is discussed.

  8. Cloud-Based Smart Health Monitoring System for Automatic Cardiovascular and Fall Risk Assessment in Hypertensive Patients.

    Science.gov (United States)

    Melillo, P; Orrico, A; Scala, P; Crispino, F; Pecchia, L

    2015-10-01

    The aim of this paper is to describe the design and the preliminary validation of a platform developed to collect and automatically analyze biomedical signals for risk assessment of vascular events and falls in hypertensive patients. This m-health platform, based on cloud computing, was designed to be flexible, extensible, and transparent, and to provide proactive remote monitoring via data-mining functionalities. A retrospective study was conducted to train and test the platform. The developed system was able to predict a future vascular event within the next 12 months with an accuracy rate of 84 % and to identify fallers with an accuracy rate of 72 %. In an ongoing prospective trial, almost all the recruited patients accepted favorably the system with a limited rate of inadherences causing data losses (<20 %). The developed platform supported clinical decision by processing tele-monitored data and providing quick and accurate risk assessment of vascular events and falls.

  9. Automatic remote monitoring utilizing daily transmissions: transmission reliability and implantable cardioverter defibrillator battery longevity in the TRUST trial.

    Science.gov (United States)

    Varma, Niraj; Love, Charles J; Schweikert, Robert; Moll, Philip; Michalski, Justin; Epstein, Andrew E

    2018-04-01

    Benefits of automatic remote home monitoring (HM) among implantable cardioverter defibrillator (ICD) patients may require high transmission frequency. However, transmission reliability and effects on battery longevity remain uncertain. We hypothesized that HM would have high transmission success permitting punctual guideline based follow-up, and improve battery longevity. This was tested in the prospective randomized TRUST trial. Implantable cardioverter defibrillator patients were randomized post-implant 2:1 to HM (n = 908) (transmit daily) or to Conventional in-person monitoring [conventional management (CM), n = 431 (HM disabled)]. In both groups, five evaluations were scheduled every 3 months for 15 months. Home Monitoring technology performance was assessed by transmissions received vs. total possible, and number of scheduled HM checks failing because of missed transmissions. Battery longevity was compared in HM vs. CM at 15 months, and again in HM 3 years post-implant using continuously transmitted data. Transmission success per patient was 91% (median follow-up of 434 days). Overall, daily HM transmissions were received in 315 795 of a potential 363 450 days (87%). Only 55/3759 (1.46%) of unsuccessful scheduled evaluations in HM were attributed to transmission loss. Shock frequency and pacing percentage were similar in HM vs. CM. Fifteen month battery longevity was 12% greater in HM (93.2 ± 8.8% vs. 83.5 ± 6.0% CM, P battery longevity was 50.9 ± 9.1% (median 52%) at 36 months. Automatic remote HM demonstrated robust transmission reliability. Daily transmission load may be sustained without reducing battery longevity. Home Monitoring conserves battery longevity and tracks long term device performance. ClinicalTrials.gov; NCT00336284.

  10. An Adaptive Monitoring Scheme for Automatic Control of Anaesthesia in dynamic surgical environments based on Bispectral Index and Blood Pressure.

    Science.gov (United States)

    Yu, Yu-Ning; Doctor, Faiyaz; Fan, Shou-Zen; Shieh, Jiann-Shing

    2018-04-13

    During surgical procedures, bispectral index (BIS) is a well-known measure used to determine the patient's depth of anesthesia (DOA). However, BIS readings can be subject to interference from many factors during surgery, and other parameters such as blood pressure (BP) and heart rate (HR) can provide more stable indicators. However, anesthesiologist still consider BIS as a primary measure to determine if the patient is correctly anaesthetized while relaying on the other physiological parameters to monitor and ensure the patient's status is maintained. The automatic control of administering anesthesia using intelligent control systems has been the subject of recent research in order to alleviate the burden on the anesthetist to manually adjust drug dosage in response physiological changes for sustaining DOA. A system proposed for the automatic control of anesthesia based on type-2 Self Organizing Fuzzy Logic Controllers (T2-SOFLCs) has been shown to be effective in the control of DOA under simulated scenarios while contending with uncertainties due to signal noise and dynamic changes in pharmacodynamics (PD) and pharmacokinetic (PK) effects of the drug on the body. This study considers both BIS and BP as part of an adaptive automatic control scheme, which can adjust to the monitoring of either parameter in response to changes in the availability and reliability of BIS signals during surgery. The simulation of different control schemes using BIS data obtained during real surgical procedures to emulate noise and interference factors have been conducted. The use of either or both combined parameters for controlling the delivery Propofol to maintain safe target set points for DOA are evaluated. The results show that combing BIS and BP based on the proposed adaptive control scheme can ensure the target set points and the correct amount of drug in the body is maintained even with the intermittent loss of BIS signal that could otherwise disrupt an automated control system.

  11. Automatic Condition Monitoring of Industrial Rolling-Element Bearings Using Motor’s Vibration and Current Analysis

    DEFF Research Database (Denmark)

    Yang, Zhenyu

    2015-01-01

    An automatic condition monitoring for a class of industrial rolling-element bearings is developed based on the vibration as well as stator current analysis. The considered fault scenarios include a single-point defect, multiple-point defects, and a type of distributed defect. Motivated by the pot...... characteristic frequencies, sideband effects, time-average of spectra, and selection of fault index and thresholds, are also discussed. The experimental work shows a huge potential to use some simple methods for successful diagnosis of industrial bearing systems.......An automatic condition monitoring for a class of industrial rolling-element bearings is developed based on the vibration as well as stator current analysis. The considered fault scenarios include a single-point defect, multiple-point defects, and a type of distributed defect. Motivated...... is extensively studied under diverse operating conditions: different sensor locations, motor speeds, loading conditions, and data samples from different time segments. The experimental results showed the powerful capability of vibration analysis in the bearing point defect fault diagnosis. The current analysis...

  12. Integrating High-Resolution Taskable Imagery into a Sensorweb for Automatic Space-Based Monitoring of Flooding in Thailand

    Science.gov (United States)

    Chien, Steve; Mclaren, David; Doubleday, Joshua; Tran, Daniel; Tanpipat, Veerachai; Chitradon, Royol; Boonya-aroonnet, Surajate; Thanapakpawin, Porranee; Mandl, Daniel

    2012-01-01

    Several space-based assets (Terra, Aqua, Earth Observing One) have been integrated into a sensorweb to monitor flooding in Thailand. In this approach, the Moderate Imaging Spectrometer (MODIS) data from Terra and Aqua is used to perform broad-scale monitoring to track flooding at the regional level (250m/pixel) and EO-1 is autonomously tasked in response to alerts to acquire higher resolution (30m/pixel) Advanced Land Imager (ALI) data. This data is then automatically processed to derive products such as surface water extent and volumetric water estimates. These products are then automatically pushed to organizations in Thailand for use in damage estimation, relief efforts, and damage mitigation. More recently, this sensorweb structure has been used to request imagery, access imagery, and process high-resolution (several m to 30m), targetable asset imagery from commercial assets including Worldview-2, Ikonos, Radarsat-2, Landsat-7, and Geo-Eye-1. We describe the overall sensorweb framework as well as new workflows and products made possible via these extensions.

  13. Validation of the Grandway MD2301 digital automatic blood pressure monitor according to the European Society of Hypertension International Protocol.

    Science.gov (United States)

    Chen, Wan; Zeng, Zhao-Lin; Bing, Sen; Li, Lin-Yi; Wang, Rui; Wan, Yi

    2016-08-01

    The aim of the present study was to validate the Grandway MD2301 digital automatic blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. The ESH-IP revision 2010 for the validation of blood pressure-measuring devices in adults was followed precisely. Systolic and diastolic blood pressure (SBP and DBP, respectively) were measured sequentially in 33 adult patients and compared with a standard mercury sphygmomanometer (two observers). A total of 99 comparison pairs were obtained. The device produced 78, 95 and 99 measurements within 5, 10, and 15 mmHg for SBP and 83, 96, and 99 for DBP, respectively. The average device-observer difference was -1.81±4.22 mmHg for SBP and -0.15±3.93 mmHg for DBP. All of the data were within the standards requirements to pass the testing. The Grandway MD2301 digital automatic blood pressure monitor meets the standards of the ESH-IP revision 2010 and can be recommended for self/home measurement in the general population.

  14. Automatic control by natural gamma radiation emitted by coal; Control Automatico mediante Radiometria Gamma Natural de la Cenizas de los Carbones

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    Due to the characteristics of its coal and orebody, Monsacro shaft was chosen to host the test. The ash percentage of the different coal seams was carried out by two different methods: Traditional analysis in laboratory. Analysis by means of natural gamma radiation emitted by coal. The following conclusions were obtained after the test: Neither during the mounting nor during the test, a problem was encountered in the working of the radioactive methods. The absolute error between the two methods was minimum. The radioactive analysis is total (this means that the whole coal is analysed) and it is carried out in short period of time. The traditional one is just partial, and could take a few hours to accomplish it. The radioactive one is done in the wagon or in the belt conveyor directly, meanwhile the traditional one needs sample takers permanently. The investment cost of the radioactivity method is amortized within two years. (Author)

  15. Video-based respiration monitoring with automatic region of interest detection

    NARCIS (Netherlands)

    Janssen, R.J.M.; Wang, Wenjin; Moço, A.; de Haan, G.

    2016-01-01

    Vital signs monitoring is ubiquitous in clinical environments and emerging in home-based healthcare applications. Still, since current monitoring methods require uncomfortable sensors, respiration rate remains the least measured vital sign. In this paper, we propose a video-based respiration

  16. Changing automatic behavior through self-monitoring: Does overt change also imply implicit change?

    NARCIS (Netherlands)

    Maas, J.; Hietbrink, L.; Rinck, M.; Keijsers, G.P.J.

    2013-01-01

    Background and objectives Self-monitoring of unwanted behavior is a common component of effective cognitive-behavioral therapy. Self-monitoring has often shown to lead to decreases in undesirable behavior. To investigate the underlying mechanisms of these ‘reactive effects’, we investigated whether

  17. Automatic laser beam alignment using blob detection for an environment monitoring spectroscopy

    Science.gov (United States)

    Khidir, Jarjees; Chen, Youhua; Anderson, Gary

    2013-05-01

    This paper describes a fully automated system to align an infra-red laser beam with a small retro-reflector over a wide range of distances. The component development and test were especially used for an open-path spectrometer gas detection system. Using blob detection under OpenCV library, an automatic alignment algorithm was designed to achieve fast and accurate target detection in a complex background environment. Test results are presented to show that the proposed algorithm has been successfully applied to various target distances and environment conditions.

  18. Diagnostic monitoring of the condition of the amplification-transformer channel of automatic gas protection apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Karpov, Ye F; Basovskiy, B I; Popov, V V

    1978-01-01

    A method is suggested for verifying the performance capacity of an amplifier-transformer channel of apparatus for automatic gas protection under operating conditions. Processes are examined which occur in the bridge measurement plan of the sensor during shunting of one of the thermal-transformer elements by a resistor. An expression is obtained for determining the coefficient of transfer of the amplification-transformer channel on the outlet signals of the apparatus in a working regime and after shunting of one of the thermal-transformer elements.

  19. Machine learning-based patient specific prompt-gamma dose monitoring in proton therapy

    Science.gov (United States)

    Gueth, P.; Dauvergne, D.; Freud, N.; Létang, J. M.; Ray, C.; Testa, E.; Sarrut, D.

    2013-07-01

    Online dose monitoring in proton therapy is currently being investigated with prompt-gamma (PG) devices. PG emission was shown to be correlated with dose deposition. This relationship is mostly unknown under real conditions. We propose a machine learning approach based on simulations to create optimized treatment-specific classifiers that detect discrepancies between planned and delivered dose. Simulations were performed with the Monte-Carlo platform Gate/Geant4 for a spot-scanning proton therapy treatment and a PG camera prototype currently under investigation. The method first builds a learning set of perturbed situations corresponding to a range of patient translation. This set is then used to train a combined classifier using distal falloff and registered correlation measures. Classifier performances were evaluated using receiver operating characteristic curves and maximum associated specificity and sensitivity. A leave-one-out study showed that it is possible to detect discrepancies of 5 mm with specificity and sensitivity of 85% whereas using only distal falloff decreases the sensitivity down to 77% on the same data set. The proposed method could help to evaluate performance and to optimize the design of PG monitoring devices. It is generic: other learning sets of deviations, other measures and other types of classifiers could be studied to potentially reach better performance. At the moment, the main limitation lies in the computation time needed to perform the simulations.

  20. Monitoring taconite process streams with thermal neutron capture-gamma ray analysis. Report of investigations/1980

    International Nuclear Information System (INIS)

    Woodbury, F.B.W.

    1980-12-01

    The Bureau of Mines is evaluating alternative technologies to treat oxidized taconites. Since process control is an essential element in the application of these process technologies, research was performed on a prototype monitoring system utilizing a californium-252 (252-Cf) neutron source and a thermal neutron capture-gamma ray spectra analysis method to measure the amount of iron and percent solids in process slurries. The prototype system was used to monitor the concentrate and tailing streams in a 900-lb/hr flotation pilot plant during continuous around-the-clock tests. The iron content of the process slurries was determined by measuring the total peak areas under the capture spectrum peaks at 7.626-7.632 MeV, the associated escape peaks at 7.136-7.122 and 6.626-6.612 MeV, and the iron doublets at 4.900 and 4.998 MeV. A potential method for determining the percent solids in process slurries using the 2.22 MeV hydrogen capture peak is discussed

  1. Machine learning-based patient specific prompt-gamma dose monitoring in proton therapy

    International Nuclear Information System (INIS)

    Gueth, P; Freud, N; Létang, J M; Sarrut, D; Dauvergne, D; Ray, C; Testa, E

    2013-01-01

    Online dose monitoring in proton therapy is currently being investigated with prompt-gamma (PG) devices. PG emission was shown to be correlated with dose deposition. This relationship is mostly unknown under real conditions. We propose a machine learning approach based on simulations to create optimized treatment-specific classifiers that detect discrepancies between planned and delivered dose. Simulations were performed with the Monte-Carlo platform Gate/Geant4 for a spot-scanning proton therapy treatment and a PG camera prototype currently under investigation. The method first builds a learning set of perturbed situations corresponding to a range of patient translation. This set is then used to train a combined classifier using distal falloff and registered correlation measures. Classifier performances were evaluated using receiver operating characteristic curves and maximum associated specificity and sensitivity. A leave-one-out study showed that it is possible to detect discrepancies of 5 mm with specificity and sensitivity of 85% whereas using only distal falloff decreases the sensitivity down to 77% on the same data set. The proposed method could help to evaluate performance and to optimize the design of PG monitoring devices. It is generic: other learning sets of deviations, other measures and other types of classifiers could be studied to potentially reach better performance. At the moment, the main limitation lies in the computation time needed to perform the simulations. (paper)

  2. Applications of gamma-ray spectrometry in real-time environmental monitoring

    International Nuclear Information System (INIS)

    Heath, R.L.; Dyer, N.C.

    1974-01-01

    The operation of large nuclear installations involves significant inventories of radioactive materials. Effective monitoring of effluent streams to permit evaluation of potential hazards which might result from discharge of radioisotopes is a requirement for safe operation of such facilities. The purpose of this paper is to present a summary of a program being conducted at the Idaho National Engineering Laboratory (INEL) to apply gamma-ray spectrometry to real-time isotopic monitoring of nuclear installations. The application of the lithium-drifted Ge spectrometer in the laboratory for isotopic assay is well established. To apply these techniques to routine on-line isotopic measurements requires the solution of a number of significant problems. These may be summarized as follows: the development of a remote pulse-height analyzer system; the development of adequate methods for analysis of pulse-amplitude spectra to permit isotopic assay and interpretation of results; and determination of basic nuclear decay data requirements for nuclides of interest to insure acceptance of isotopic assay results

  3. Gamma Monitoring of Land Surfaces; Controle Gamma des Surfaces Terrestres; 0413 0410 041c 041c 0410 - 0414 ; Control de la Actividad Gamma en la Superficie del Terreno

    Energy Technology Data Exchange (ETDEWEB)

    Ophel, I. L.; Jones, A. R. [Environmental Research and Radiation Dosimetry Branch, Division of Biology and Health Physics, Atomic Energy of Canada Limited, Chalk River, ON (Canada)

    1960-07-01

    Rapid monitoring of land surfaces is useful in delineating the area affected by an accident involving airborne contamination or detecting long-term contamination of the environment. A rugged monitor capable of making a continuous record when carried on a vehicle has been used for carrying out a pre-operational survey of the area surrounding the site of the NPD power reactor near Chalk River. It consists of an anthracene crystal {gamma}-ray detector with a photomultiplier, pulse-amplifier, counting-rate circuit, DC amplifier, 1-mA recorder train. This equipment weighs 28 kg and is mounted with two bolts on the bumper of a jeep. It can be dismounted and set up on a tripod at the same height above the ground. The mercury batteries are kept inside the vehicle. The circuitry is transistorized. A jig is fitted to carry a standard radium calibration source. The instrument is insensitive to cosmic radiation, and when the vehicle was driven at 16 km/h readings were 80% of those obtained if the counter was stationary. A road survey of the NPD reactor area, with readings also taken at fixed check points 100 m from the roadway and 3.2 km apart, showed that the recorded background radiation on the roads was very uniform, averaging 6 {mu}r/h. Check-point readings varied from 4.5 to 7.0 {mu}r/h. (author) [French] Un controle rapide des surfaces terrestres est utile pour delimiter la zone contaminee a la suite d'un accident ayant provoque une pollution radioactive de l'atmosphere, ou pour deceler une contamination a long terme du milieu ambiant. On a utilise un appareil tres resistant, capable d'assurer un enregistrement continu lorsqu'il est autoporte, et l'on a fait un controle de la zone entourant l'emplacement du reacteur de puissance NPD, pres de Chalk River, avant la mise en service de l'installation. L'appareil se compose d'un detecteur - cristal d'anthracene, photomultiplicateur et amplificateur - et d'un dispositif de mesure et d'enregistrement - amplificateur a courant

  4. Triplicate Sodium Iodide Gamma Ray Monitors For The Small Column Ion Exchange Program

    International Nuclear Information System (INIS)

    Couture, A.

    2011-01-01

    This technical report contains recommendations from the Analytical Development (AD) organization of the Savannah River National Laboratory (SRNL) for a system of triplicate Sodium Iodide (NaI) detectors to be used to monitor Cesium-137 ( 137 Cs) content of the Decontaminated Salt Solution (DSS) output of the Small Column Ion Exchange (SCIX) process. These detectors need to be gain stabilized with respect to temperature shifts since they will be installed on top of Tank 41 at the Savannah River Site (SRS). This will be accomplished using NaI crystals doped with the alpha-emitting isotope, Americium-241( 241 Am). Two energy regions of the detector output will be monitored using single-channel analyzers (SCAs), the 137 Cs full-energy γ-ray peak and the 241 Am alpha peak. The count rate in the gamma peak region will be proportional to the 137 Cs content in the DSS output. The constant rate of alpha decay in the NaI crystal will be monitored and used as feedback to adjust the high voltage supply to the detector in response to temperature variation. An analysis of theoretical 137 Cs breakthrough curves was used to estimate the gamma activity expected in the DSS output during a single iteration of the process. Count rates arising from the DSS and background sources were predicted using Microshield modeling software. The current plan for shielding the detectors within an enclosure with four-inch thick steel walls should allow the detectors to operate with the sensitivity required to perform these measurements. Calibration, testing, and maintenance requirements for the detector system are outlined as well. The purpose of SCIX is to remove and concentrate high-level radioisotopes from SRS salt waste resulting in two waste streams. The concentrated high-level waste containing 137 Cs will be sent to the Defense Waste Processing Facility (DWPF) for vitrification and the low-level DSS will be sent to the Saltstone Production Facility (SPF) to be incorporated into grout.

  5. GSM Web-Based Centralized Remote Wireless Automatic Controlling and Monitoring of Aquafeeder

    Science.gov (United States)

    Wong, C. L.; Idris, A.; Hasan, Z.

    2016-03-01

    This project is about producing a prototype to feed fishes at fish ponds of remote location with the use of GSM mobile phone. An automatic fish feeder is an electric device that has been designed to give out the right amount of pellets at the designed time. In this project, the automatic feeder designed consists of photovoltaic solar cells that are used to generate electricity and storing it into batteries. Solar charge controllers can be used to determine the rate of which current is drawn and added from the batteries. GSM cellular communication is used to allow user to control from a distance. Commands or instructions are sent to the operating system which in return runs the servomotor and blower by blowing certain amount of fish pallets into the pond to feed the fishes. The duration of the feeding processes is fixed by the user, hence the amount of fish food pallets released are precisely the same for each time. This technology is especially useful for fish farmers where they can remotely feed their fishes.

  6. Automatic Sensor-Fault Detection System for Comprehensive Structural Health Monitoring System

    National Research Council Canada - National Science Library

    Chan, Hian-Leng; Zhang, Chang; Qing, Peter X; Ooi, Teng K; Marotta, Steve A

    2005-01-01

    Structural health monitoring systems are viewed as viable means to reduce life-cycle costs, increase structural reliability, and extend the operational hours for a wide variety of composite structures...

  7. Automatic cross-sectioning and monitoring system locates defects in electronic devices

    Science.gov (United States)

    Jacobs, G.; Slaughter, B.

    1971-01-01

    System consists of motorized grinding and lapping apparatus, sample holder, and electronic control circuit. Low power microscope examines device to pinpoint location of circuit defect, and monitor displays output signal when defect is located exactly.

  8. NPP Temelin automatic monitoring and diagnostic system of secondary side of the unit 1

    International Nuclear Information System (INIS)

    Heidenreich, S.; Pisl, M.; Drab, F.

    1997-01-01

    Two measuring and evaluating systems by SKODA PRAHA are described, designed for the Temelin nuclear power plant: a permanent secondary side diagnostic system for technology monitoring in the period of startup and operation; and the system of physical and power starting-up for monitoring during the first and repeated startup. The purposes of both systems are outlined. The scope of diagnostics covered and the functioning of the secondary side system is dealt with in some detail. (A.K.)

  9. Estimating a possibility for automatized monitoring radioactive aerosols in the Ukrytie Object air

    International Nuclear Information System (INIS)

    Zalmanzon, Yu.B.; Fertman, D.E.

    1989-01-01

    The aim of the paper is to study the measurement specifications of the BDAS-OZP industrial detection unit for monitoring aerosols, produced in the Ukrytie object rooms. It is shown that the unit ensures monitoring alpha-active aerosols with radionuclide content of 3x10 -15 Ci/l and beta-active ones - with 3x10 -13 Ci/l. 2 refs.; 1 tabs

  10. Application of radcal gamma thermometer assemblies for coolant monitoring in Ringhals W-PWRs

    International Nuclear Information System (INIS)

    Smith, R.D.; Romslo, K.; Moen, Oe.

    1982-07-01

    A study has been carried out investigating how Radcal Gamma Thermometers (RGTs) can be used for coolant inventory and core cooling monitoring in the Ringhals Westinghouse PWRs. The study concludes that two types of RGT rods would be required to come up with a complete solution covering both coolant inventory and core cooling monitoring. Above-core RGT rods will be installed in the guide tubes housing the outlet thermocouples. The Above-Core RGT rod is designed with 8 sensors where 4 are located in the upper head and 4 in the plenum. This rod will give an early warning about loss of coolant or void formation in the space from top of fuel to the reactor lid. A ninth thermocouple in this rod will measure the core outlet temperature as did the thermocouple the RGT rod replaced. The Above-Core RGT rods will give an early warning about approach to Inadequate Core Cooling (ICC) by measuring the collapsed water level inside the thermocouple guide tube. Four such rods are recommended per reactor. In-Core RGT rods are inserted from the seal table. These rods will give the information required for intelligent accident management in case ICC has developed. The signals obtainable from the rods will give direct information about fuel decay heat, core heat transfer conditions, core temperature and core coolant water level. The In-Core RGT rods can be used for local power monitoring during normal operation. Such a system can be shown to be economically motivated from a reactor operation point of view due to increased sensor lifetime, more accurate local power measurements, simpler physics corrections to signals, lower exposure to maintenance personnel. The signal transmission to the control room has been discussed, and ways have been indicated for presenting the information available to the operators. (Authors)

  11. Threshold self-powered gamma detector for use as a monitor of power in a nuclear reactor

    Science.gov (United States)

    LeVert, Francis E.; Cox, Samson A.

    1978-01-01

    A self-powered gamma monitor for placement near the core of a nuclear reactor comprises a lead prism surrounded by a coaxial thin nickel sheet, the combination forming a collector. A coaxial polyethylene electron barrier encloses the collector and is separated from the nickel sheet by a vacuum region. The electron barrier is enclosed by a coaxial stainless steel emitter which, in turn, is enclosed within a lead casing. When the detector is placed in a flux of gamma rays, a measure of the current flow in an external circuit between emitter and collector provides a measure of the power level of the reactor.

  12. Threshold self-powered gamma detector for use as a monitor of power in a nuclear reactor

    International Nuclear Information System (INIS)

    LeVert, F.E.; Cox, S.A.

    1978-01-01

    A self-powered gamma monitor for placement near the core of a nuclear reactor comprises a lead prism surrounded by a coaxial thin nickel sheet, the combination forming a collector. A coaxial polyethylene electron barrier encloses the collector and is separated from the nickel sheet by a vacuum region. The electron barrier is enclosed by a coaxial stainless steel emitter which, in turn, is enclosed within a lead casing. When the detector is placed in a flux of gamma rays, a measure of the current flow in an external circuit between emitter and collector provides a measure of the power level of the reactor

  13. Mobile sailing robot for automatic estimation of fish density and monitoring water quality.

    Science.gov (United States)

    Koprowski, Robert; Wróbel, Zygmunt; Kleszcz, Agnieszka; Wilczyński, Sławomir; Woźnica, Andrzej; Łozowski, Bartosz; Pilarczyk, Maciej; Karczewski, Jerzy; Migula, Paweł

    2013-07-01

    The paper presents the methodology and the algorithm developed to analyze sonar images focused on fish detection in small water bodies and measurement of their parameters: volume, depth and the GPS location. The final results are stored in a table and can be exported to any numerical environment for further analysis. The measurement method for estimating the number of fish using the automatic robot is based on a sequential calculation of the number of occurrences of fish on the set trajectory. The data analysis from the sonar concerned automatic recognition of fish using the methods of image analysis and processing. Image analysis algorithm, a mobile robot together with its control in the 2.4 GHz band and full cryptographic communication with the data archiving station was developed as part of this study. For the three model fish ponds where verification of fish catches was carried out (548, 171 and 226 individuals), the measurement error for the described method was not exceeded 8%. Created robot together with the developed software has features for remote work also in the variety of harsh weather and environmental conditions, is fully automated and can be remotely controlled using Internet. Designed system enables fish spatial location (GPS coordinates and the depth). The purpose of the robot is a non-invasive measurement of the number of fish in water reservoirs and a measurement of the quality of drinking water consumed by humans, especially in situations where local sources of pollution could have a significant impact on the quality of water collected for water treatment for people and when getting to these places is difficult. The systematically used robot equipped with the appropriate sensors, can be part of early warning system against the pollution of water used by humans (drinking water, natural swimming pools) which can be dangerous for their health.

  14. Standard guide for in-plant performance evaluation of automatic pedestrian SNM monitors

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This guide is affiliated with Guide C1112 on special nuclear material (SNM) monitors, Guide C1169 on laboratory performance evaluation, and Guide C1189 on calibrating pedestrian SNM monitors. This guide to in-plant performance evaluation is a comparatively rapid way to verify whether a pedestrian SNM monitor performs as expected for detecting SNM or SNM-like test sources. 1.1.1 In-plant performance evaluation should not be confused with the simple daily functional test recommended in Guide C1112. In-plant performance evaluation takes place less often than daily tests, usually at intervals ranging from weekly to once every three months. In-plant evaluations are also more extensive than daily tests and may examine both a monitor's nuisance alarm record and its detection sensitivity for a particular SNM or alternative test source. 1.1.2 In-plant performance evaluation also should not be confused with laboratory performance evaluation. In-plant evaluation is comparatively rapid, takes place in the monitor...

  15. Development of a multiplexer for an automatic data acquisition system for the control and monitoring of microbiological cultures

    Energy Technology Data Exchange (ETDEWEB)

    Morales Rondon, A.; Paredes Puente, J.; Arana Alonso, S.

    2016-07-01

    An automatic data acquisition system has been developed for the control and monitoring of microbiological cultures. Turning an otherwise time-consuming process into a smooth one, by allowing the researcher to set the parameters at the beginning of the experiment and move on into the next task. The development of the hardware and software are key to achieving this system. The mux is custom-made with 22 channels, light weight therefore easy to move around the lab. Furthermore, the software allows the researcher to check the measurements in real-time. It is based on virtual instrumentation software therefore new features can be added easily, thus, the mux is capable of adapting to the scientist necessities. (Author)

  16. Expert system for the automatic analysis of the Eddy current signals from the monitoring of vapor generators of a PWR, type reactor

    International Nuclear Information System (INIS)

    Lefevre, F.; Baumaire, A.; Comby, R.; Benas, J.C.

    1990-01-01

    The automatization of the monitoring of the steam generator tubes required some developments in the field of data processing. The monitoring is performed by means of Eddy current tests. Improvements in signal processing and in pattern recognition associated to the artificial intelligence techniques induced EDF (French Electricity Company) to develop an automatic signal processing system. The system, named EXTRACSION (French acronym for Expert System for the Processing and classification of Signals of Nuclear Nature), insures the coherence between the different fields of knowledge (metallurgy, measurement, signals) during data processing by applying an object oriented representation [fr

  17. Automatic semi-continuous accumulation chamber for diffuse gas emissions monitoring in volcanic and non-volcanic areas

    Science.gov (United States)

    Lelli, Matteo; Raco, Brunella; Norelli, Francesco; Virgili, Giorgio; Continanza, Davide

    2016-04-01

    Since various decades the accumulation chamber method is intensively used in monitoring activities of diffuse gas emissions in volcanic areas. Although some improvements have been performed in terms of sensitivity and reproducibility of the detectors, the equipment used for measurement of gas emissions temporal variation usually requires expensive and bulky equipment. The unit described in this work is a low cost, easy to install-and-manage instrument that will make possible the creation of low-cost monitoring networks. The Non-Dispersive Infrared detector used has a concentration range of 0-5% CO2, but the substitution with other detector (range 0-5000 ppm) is possible and very easy. Power supply unit has a 12V, 7Ah battery, which is recharged by a 35W solar panel (equipped with charge regulator). The control unit contains a custom programmed CPU and the remote transmission is assured by a GPRS modem. The chamber is activated by DataLogger unit, using a linear actuator between the closed position (sampling) and closed position (idle). A probe for the measure of soil temperature, soil electrical conductivity, soil volumetric water content, air pressure and air temperature is assembled on the device, which is already arranged for the connection of others external sensors, including an automatic weather station. The automatic station has been tested on the field at Lipari island (Sicily, Italy) during a period of three months, performing CO2 flux measurement (and also weather parameters), each 1 hour. The possibility to measure in semi-continuous mode, and at the same time, the gas fluxes from soil and many external parameters, helps the time series analysis aimed to the identification of gas flux anomalies due to variations in deep system (e.g. onset of volcanic crises) from those triggered by external conditions.

  18. Analysis of proposed gamma-ray detection system for the monitoring of core water inventory in a pressurized water reactor

    International Nuclear Information System (INIS)

    Markoff, D.M.

    1987-12-01

    An initial study has been performed of the feasibility of employing an axial array of gamma detectors located outside the pressure vessel to monitor the coolant in a PWR. A one-dimensional transport analysis model is developed for the LOFT research reactor and for a mock-PWR geometry. The gamma detector response to coolant voiding in the core and downcomer has been determined for both geometries. The effects of various conditions (for example, time after shutdown, materials in the transport path, and the relative void fraction in different water regions) on the detector response are studied. The calculational results have been validated by a favorable comparison with LOFT experimental data. Within the limitations and approximations considered in the analysis, the results indicate that the gamma-ray detection scheme is able to unambiguously respond to changes in the coolant inventory within any vessel water region

  19. The NETLAKE Metadatabase – A tool to support automatic monitoring on lakes in Europe and beyond

    Czech Academy of Sciences Publication Activity Database

    Jennings, E.; de Eyto, E.; Laas, A.; Pierson, D. C.; Mircheva, G.; Naumoski, A.; Clarke, A.; Helay, M.; Šumberová, Kateřina; Langenhaun, D.

    2017-01-01

    Roč. 26, č. 4 (2017), s. 95-100 ISSN 1539-607X Grant - others:COST(XE) ES1201 Program:ES Institutional support: RVO:67985939 Keywords : sensor -based monitoring * data sharing * lakes and reservoirs Subject RIV: DA - Hydrology ; Limnology OBOR OECD: Marine biology, freshwater biology, limnology

  20. Quality audits of the remote-controlled automatically-driven gamma ray afterloading equipment used in brachytherapy in the Czech Republic

    International Nuclear Information System (INIS)

    Zackova, H.; Horakova, I.

    2001-01-01

    To reach safety and precise application of ionisation radiation to patients Atomic act declares, in its Article no. 7, requirements for medical exposure. There are also given -among others -the demands to i nstall the quality assurance programmes (QA) for medical actions and functions . Since 1997, when the act has been adopted, a set of five Recommendations of State Office for Nuclear Safety (SONS ) for radiotherapy has been prepared to instruct users how to prepare quality control system (i.e. system of tests required by of the regulation no.184/1997 Sb. -acceptance, status and constancy tests) for main types of sources used in radiotherapy for treatment of the patients. Among them also the Recommendation on QA in brachytherapy has been issued by SONS in 1998. National Radiation Protection Institute (NRPI) has been performing the regular in situ quality audits in which the chosen parameters (which could seriously influence the dose to the patients -i.e. absorbed dose, main geometrical and radiation parameters etc ) are independently checked by the NRPI experts. System of Quality Audits on the sources used in teletherapy has been introduced in 1997 and at present time they are smoothly carried out according the SONS's demands. This work describes the process of installing of the Quality Audit system on brachytherapy. The work described here forms the only part of the activities, which have been carrying out by the department of dosimetry gamma and X-rays of NRPI to support supervisions of SONS in the field of radiation protection in radiotherapy .Quality audits in brachytherapy will extend the possibilities of NRPI. The Methods NRPI 43-01.30 prepared by NRPI could be used as documentation for all types of test which are at present time required by Czech legislation for the remote-controlled automatically-driven gamma-ray afterloading equipment used in brachytherapy. (authors)

  1. Development and Performance Characteristics of Personal Gamma Spectrometer for Radiation Monitoring Applications

    Directory of Open Access Journals (Sweden)

    Hye Min Park

    2016-06-01

    Full Text Available In this study, a personal gamma (γ spectrometer was developed for use in applications in various fields, such as homeland security and environmental radiation monitoring systems. The prototype consisted of a 3 × 3 × 20 mm3 Ce-doped Gd–Al–Ga–garnet (Ce:GAGG crystal that was coupled to a Si photomultiplier (SiPM to measure γ radiation. The γ spectrometer could be accessed remotely via a mobile device. At room temperature, the implemented Ce:GAGG-SiPM spectrometer achieved energy resolutions of 13.5%, 6.9%, 5.8%, and 2.3% for 133Ba at 0.356 MeV, 22Na at 0.511 MeV, 137Cs at 0.662 MeV, and 60Co at 1.33 MeV, respectively. It consumed only about 2.7 W of power, had a mass of just 340 g (including the battery, and measured only 5.0 × 7.0 cm2.

  2. A gamma camera method to monitor the use of degradable starch microspheres in hepatic arterial chemotherapy

    International Nuclear Information System (INIS)

    Britten, A.; Fleming, J.; Flowerdew, A.; Hunt, T.; Taylor, I.; Ackery, D.

    1989-01-01

    A gamma camera method to quantify the haemodynamic effects of degradable starch microspheres (DSM) in intra arterial hepatic therapy is described. Results are presented from ten patients with colorectal liver metastases. Intra hepatic arterio venous shunting was present in 1 patient prior to DSM and in 2 subjects after three 300 mg DSM fractions. DSM reduced the rate of flow of injectate to the lung in all cases. Conversely, an increased rate of flow of injectate to gut or spleen occurred with 300 mg fractions of DSM in 7/9 cases. Lower dose DSM fractions are indicated. At 2-3 min after DSM injection the mean fraction of the activity retained in the liver was 0.22. A DSM induced enhancement of tumour relative to normal tissue perfusion was obtained in four out of five tumour regions identified. All indices showed a wide variation between patients and between individual DSM doses, and the high incidence of extra hepatic shunting confirms the need for monitoring when using intra arterial microspheres. (orig.)

  3. Monitoring method for an ambient Gamma exposure rate and its measurement analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Mo Sung [Cheongju Univ., Cheongju (Korea, Republic of); Woo, Jong Kwan [University of Seoul, Seoul (Korea, Republic of)

    2006-12-15

    Daily and seasonal variations of the ambient gamma ray exposure rates were measured by using a pressurized ion chamber from January 2003 to December 2005 in the Cheongju Regional Radiation Monitoring Post and the patterns of the distributions were studied. The annual average of the daily variation of the exposure rate was {approx}0.17 {mu}R/h. The exposure rate was found to be maximum during 8:00 am to 9:00 am and minimum during 8:00 pm to 10:00 pm. For the annual data, the exposure rate was the minimum during the month of February. The exposure rate increased from February to mid-October (except during the period from May to July with no change) and decreased from October to February. The seasonal variation was found to be about 1 {mu}R/h. Most of the measured values (96%) of the exposure rates fell under the normal distribution with a deviation of less than 4.8% and the remaining 4% had large fluctuations caused mainly by the rainfalls.

  4. Automatization of the Calibration Laboratory for Radiation Monitors of the IRD

    International Nuclear Information System (INIS)

    Cabral, Tania S.; Ramos, Manoel M.O.; Quaresma, Daniel S.

    2007-01-01

    This work will present the concluded stages and also the ones that are still in process to reach the full automation of the calibration system. Little by little the laboratory included in its installations the automatization of some of its operations, aiming the safety of the staff and their equipment. The automation makes the installation almost ideal for the radioprotection, that is, makes its exposure as low as possible and the routines more accurate, minimizing attributed the uncertainties and the doses received by the professionals who operated the system manually. Currently, on the operation table there is a control of the position car exists and its speed, the internal TV circuit (of the room, the position of the car and equipment that is going to be calibrated), the control of the registration is done by the Autolab program and the Irradiator Buchler OB85 control with the sources of 137Cs and 60Co.A next stage will be the implantation of the automation project of the positioning of the three used attenuators. (author)

  5. LONG-TERM MONITORING OF MRK 501 FOR ITS VERY HIGH ENERGY {gamma} EMISSION AND A FLARE IN 2011 OCTOBER

    Energy Technology Data Exchange (ETDEWEB)

    Bartoli, B.; Catalanotti, S. [Dipartimento di Fisica dell' Universita di Napoli ' Federico II' , Complesso Universitario di Monte Sant' Angelo, via Cinthia, I-80126 Napoli (Italy); Bernardini, P.; Bleve, C. [Dipartimento di Matematica e Fisica ' E. De Giorgi' dell' Universita del Salento, via per Arnesano, I-73100 Lecce (Italy); Bi, X. J.; Cao, Z.; Chen, S. Z.; Chen, Y. [Key Laboratory of Particle Astrophysics, Institute of High Energy Physics, Chinese Academy of Sciences, P.O. Box 918, 100049 Beijing (China); Bolognino, I. [Dipartimento di Fisica Nucleare e Teorica dell' Universita di Pavia, via Bassi 6, I-27100 Pavia (Italy); Branchini, P.; Budano, A. [Istituto Nazionale di Fisica Nucleare, Sezione di Roma Tre, via della Vasca Navale 84, I-00146 Roma (Italy); Calabrese Melcarne, A. K. [Istituto Nazionale di Fisica Nucleare-CNAF, Viale Berti-Pichat 6/2, I-40127 Bologna (Italy); Camarri, P. [Dipartimento di Fisica dell' Universita di Roma ' Tor Vergata' , via della Ricerca Scientifica 1, I-00133 Roma (Italy); Cardarelli, R. [Istituto Nazionale di Fisica Nucleare, Sezione di Roma Tor Vergata, via della Ricerca Scientifica 1, I-00133 Roma (Italy); Cattaneo, C. [Istituto Nazionale di Fisica Nucleare, Sezione di Pavia, via Bassi 6, I-27100 Pavia (Italy); Chen, T. L. [Tibet University, 850000 Lhasa, Xizang (China); Creti, P. [Istituto Nazionale di Fisica Nucleare, Sezione di Lecce, via per Arnesano, I-73100 Lecce (Italy); Cui, S. W. [Hebei Normal University, Shijiazhuang 050016, Hebei (China); Dai, B. Z. [Yunnan University, 2 North Cuihu Rd., 650091 Kunming, Yunnan (China); D' Ali Staiti, G., E-mail: chensz@ihep.ac.cn [Dipartimento di Fisica e Tecnologie Relative, Universita degli Studi di Palermo, Viale delle Scienze, Edificio 18, I-90128 Palermo (Italy); Collaboration: ARGO-YBJ Collaboration; and others

    2012-10-10

    As one of the brightest active blazars in both X-ray and very high energy {gamma}-ray bands, Mrk 501, is very useful for physics associated with jets from active galactic nuclei. The ARGO-YBJ experiment has monitored Mrk 501 for {gamma}-rays above 0.3 TeV since 2007 November. The largest flare since 2005 was observed from 2011 October and lasted until about 2012 April. In this paper, a detailed analysis of this event is reported. During the brightest {gamma}-ray flaring episodes from 2011 October 17 to November 22, an excess of the event rate over 6{sigma} is detected by ARGO-YBJ in the direction of Mrk 501, corresponding to an increase of the {gamma}-ray flux above 1 TeV by a factor of 6.6 {+-} 2.2 from its steady emission. In particular, the {gamma}-ray flux above 8 TeV is detected with a significance better than 4{sigma}. Based on time-dependent synchrotron self-Compton (SSC) processes, the broadband energy spectrum is interpreted as the emission from an electron energy distribution parameterized with a single power-law function with an exponential cutoff at its high-energy end. The average spectral energy distribution for the steady emission is well described by this simple one-zone SSC model. However, the detection of {gamma}-rays above 8 TeV during the flare challenges this model due to the hardness of the spectra. Correlations between X-rays and {gamma}-rays are also investigated.

  6. Development and implementation of an automated system for antiquated of the process of gamma radiation monitors calibration

    International Nuclear Information System (INIS)

    Silva Junior, Iremar Alves

    2012-01-01

    In this study it was carried out the development and implementation of a system for the appropriate process of gamma radiation monitors calibration, constituted by a pneumatic dispositive to exchange the attenuators and a positioning table, both actuated through a control panel. We also implemented a System of Caesa-Gammatron Irradiator, which increased the range of the air kerma rates, due to its higher activity comparing with the current system of gamma radiation in use in the calibration laboratory of gamma irradiation. Hence, it was necessary the installation of an attenuator dispositive remotely controlled in this irradiator system. Lastly, it was carried out an evaluation of the reduction in the rates of the occupational dose. This dissertation was developed with the aim of improving the quality of the services of calibration and tests of gamma radiation monitors - provided by the IPEN Laboratory of Instrument Calibration - as well as decreasing the occupational dose of the technicians involved in the process of calibration, following thus the principles of radiation protection. (author)

  7. Automatic algorithm for monitoring systolic pressure variation and difference in pulse pressure.

    Science.gov (United States)

    Pestel, Gunther; Fukui, Kimiko; Hartwich, Volker; Schumacher, Peter M; Vogt, Andreas; Hiltebrand, Luzius B; Kurz, Andrea; Fujita, Yoshihisa; Inderbitzin, Daniel; Leibundgut, Daniel

    2009-06-01

    Difference in pulse pressure (dPP) reliably predicts fluid responsiveness in patients. We have developed a respiratory variation (RV) monitoring device (RV monitor), which continuously records both airway pressure and arterial blood pressure (ABP). We compared the RV monitor measurements with manual dPP measurements. ABP and airway pressure (PAW) from 24 patients were recorded. Data were fed to the RV monitor to calculate dPP and systolic pressure variation in two different ways: (a) considering both ABP and PAW (RV algorithm) and (b) ABP only (RV(slim) algorithm). Additionally, ABP and PAW were recorded intraoperatively in 10-min intervals for later calculation of dPP by manual assessment. Interobserver variability was determined. Manual dPP assessments were used for comparison with automated measurements. To estimate the importance of the PAW signal, RV(slim) measurements were compared with RV measurements. For the 24 patients, 174 measurements (6-10 per patient) were recorded. Six observers assessed dPP manually in the first 8 patients (10-min interval, 53 measurements); no interobserver variability occurred using a computer-assisted method. Bland-Altman analysis showed acceptable bias and limits of agreement of the 2 automated methods compared with the manual method (RV: -0.33% +/- 8.72% and RV(slim): -1.74% +/- 7.97%). The difference between RV measurements and RV(slim) measurements is small (bias -1.05%, limits of agreement 5.67%). Measurements of the automated device are comparable with measurements obtained by human observers, who use a computer-assisted method. The importance of the PAW signal is questionable.

  8. Fourth IRMF comparison of calibrations of portable gamma-ray dose- rate monitors 2001-2002 Ionising radiation

    CERN Document Server

    Lewis, V E

    2002-01-01

    The Ionising Radiations Metrology Forum (IRMF) organised a fourth comparison of calibrations of gamma-ray dose-rate monitors in which fifteen establishments in the UK participated. The exercise involved the circulation of three gamma-ray monitors for calibration in the fields produced using sup 1 sup 3 sup 7 Cs, sup 2 sup 4 sup 1 Am and sup 6 sup 0 Co. The instruments used were an Electra with MC 20 probe, a Mini-Instruments Mini-rad 1000 and a Siemens electronic personal dosemeter Mk 2 (EPD). The responses relative to 'true' dose equivalent rate were calculated by the individual participants and submitted to the for analysis along with details of the facilities and fields employed. Details of the estimated uncertainties were also reported. The results are compared and demonstrate generally satisfactory agreement between the participating establishments. However, the participants' treatment of uncertainties needs improvement and demonstrates a need for guidance in this area.

  9. Automatic Condition Monitoring of Industrial Rolling-Element Bearings Using Motor’s Vibration and Current Analysis

    Directory of Open Access Journals (Sweden)

    Zhenyu Yang

    2015-01-01

    Full Text Available An automatic condition monitoring for a class of industrial rolling-element bearings is developed based on the vibration as well as stator current analysis. The considered fault scenarios include a single-point defect, multiple-point defects, and a type of distributed defect. Motivated by the potential commercialization, the developed system is promoted mainly using off-the-shelf techniques, that is, the high-frequency resonance technique with envelope detection and the average of short-time Fourier transform. In order to test the flexibility and robustness, the monitoring performance is extensively studied under diverse operating conditions: different sensor locations, motor speeds, loading conditions, and data samples from different time segments. The experimental results showed the powerful capability of vibration analysis in the bearing point defect fault diagnosis. The current analysis also showed a moderate capability in diagnosis of point defect faults depending on the type of fault, severity of the fault, and the operational condition. The temporal feature indicated a feasibility to detect generalized roughness fault. The practical issues, such as deviations of predicted characteristic frequencies, sideband effects, time-average of spectra, and selection of fault index and thresholds, are also discussed. The experimental work shows a huge potential to use some simple methods for successful diagnosis of industrial bearing systems.

  10. RAW MILK IN AUTOMATIC SALE MACHINES: MONITORING PLAN IN PIEDEMONT REGION

    Directory of Open Access Journals (Sweden)

    S. Gallina

    2010-06-01

    Full Text Available Raw milk at vending machine is surging in popularity amongst consumers of Northern Italy; indeed in Piedmont Region there are more than 100 vending machines. In June 2008 Piedmont Region set out a specific monitoring plan to check the milk quality. From June to December 2008, 113 raw milk samples were collected at vending machines. Samples were analysed for Listeria monocytogenes, Salmonella spp., coagulase positive staphylococci, Staphylococcus aureus and Campylobacter. Moreover, 100 samples were analysed for the quantification of aflatoxin M1. 26 samples have been resulted Not Conform for the hygienic criteria and 1 exceeded the aflatoxin M1 limit.

  11. Automatic Threshold Setting and Its Uncertainty Quantification in Wind Turbine Condition Monitoring System

    DEFF Research Database (Denmark)

    Marhadi, Kun Saptohartyadi; Skrimpas, Georgios Alexandros

    2015-01-01

    Setting optimal alarm thresholds in vibration based condition monitoring system is inherently difficult. There are no established thresholds for many vibration based measurements. Most of the time, the thresholds are set based on statistics of the collected data available. Often times the underly......Setting optimal alarm thresholds in vibration based condition monitoring system is inherently difficult. There are no established thresholds for many vibration based measurements. Most of the time, the thresholds are set based on statistics of the collected data available. Often times...... the underlying probability distribution that describes the data is not known. Choosing an incorrect distribution to describe the data and then setting up thresholds based on the chosen distribution could result in sub-optimal thresholds. Moreover, in wind turbine applications the collected data available may...... not represent the whole operating conditions of a turbine, which results in uncertainty in the parameters of the fitted probability distribution and the thresholds calculated. In this study, Johnson, Normal, and Weibull distributions are investigated; which distribution can best fit vibration data collected...

  12. Fully automatic flow-based device for monitoring of drug permeation across a cell monolayer.

    Science.gov (United States)

    Zelená, Lucie; Marques, Sara S; Segundo, Marcela A; Miró, Manuel; Pávek, Petr; Sklenářová, Hana; Solich, Petr

    2016-01-01

    A novel flow-programming setup based on the sequential injection principle is herein proposed for on-line monitoring of temporal events in cell permeation studies. The permeation unit consists of a Franz cell with its basolateral compartment mixed under mechanical agitation and thermostated at 37 °C. The apical compartment is replaced by commercially available Transwell inserts with a precultivated cell monolayer. The transport of drug substances across epithelial cells genetically modified with the P-glycoprotein membrane transporter (MDCKII-MDR1) is monitored on-line using rhodamine 123 as a fluorescent marker. The permeation kinetics of the marker is obtained in a fully automated mode by sampling minute volumes of solution from the basolateral compartment in short intervals (10 min) up to 4 h. The effect of a P-glycoprotein transporter inhibitor, verapamil as a model drug, on the efficiency of the marker transport across the cell monolayer is thoroughly investigated. The analytical features of the proposed flow method for cell permeation studies in real time are critically compared against conventional batch-wise procedures and microfluidic devices.

  13. ODM Data Analysis-A tool for the automatic validation, monitoring and generation of generic descriptive statistics of patient data.

    Science.gov (United States)

    Brix, Tobias Johannes; Bruland, Philipp; Sarfraz, Saad; Ernsting, Jan; Neuhaus, Philipp; Storck, Michael; Doods, Justin; Ständer, Sonja; Dugas, Martin

    2018-01-01

    A required step for presenting results of clinical studies is the declaration of participants demographic and baseline characteristics as claimed by the FDAAA 801. The common workflow to accomplish this task is to export the clinical data from the used electronic data capture system and import it into statistical software like SAS software or IBM SPSS. This software requires trained users, who have to implement the analysis individually for each item. These expenditures may become an obstacle for small studies. Objective of this work is to design, implement and evaluate an open source application, called ODM Data Analysis, for the semi-automatic analysis of clinical study data. The system requires clinical data in the CDISC Operational Data Model format. After uploading the file, its syntax and data type conformity of the collected data is validated. The completeness of the study data is determined and basic statistics, including illustrative charts for each item, are generated. Datasets from four clinical studies have been used to evaluate the application's performance and functionality. The system is implemented as an open source web application (available at https://odmanalysis.uni-muenster.de) and also provided as Docker image which enables an easy distribution and installation on local systems. Study data is only stored in the application as long as the calculations are performed which is compliant with data protection endeavors. Analysis times are below half an hour, even for larger studies with over 6000 subjects. Medical experts have ensured the usefulness of this application to grant an overview of their collected study data for monitoring purposes and to generate descriptive statistics without further user interaction. The semi-automatic analysis has its limitations and cannot replace the complex analysis of statisticians, but it can be used as a starting point for their examination and reporting.

  14. Special nuclear material radiation monitors for the 1980's

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1985-01-01

    During the two decades that automatic gamma-radiation monitors have been applied to detecting special nuclear material (SNM), little attention has been devoted to how well the monitors perform in plant environments. Visits to 11 DOE facilities revealed poor information flow between developers, manufacturers, and maintainers of SNM radiation monitors. To help users achieve best performance from their monitors or select new ones, Los Alamos National Laboratory developed a hand-held monitor user's guide, calibration manuals for some commercial SNM pedestrian monitors, and an application guide for SNM pedestrian monitors. In addition, Los Alamos evaluated new commercial SNM monitors, considered whether to apply neutron detection to SNM monitoring, and investigated the problem of operating gamma-ray SNM monitors in variable plutonium gamma-radiation fields. As a result, the performance of existing SNM monitors will improve and alternative monitoring methods will become commerciallly available during the 1980s. 9 refs., 6 figs., 1 tab

  15. [The implications of the automatic blood pressure monitoring (ABPM) in the type I diabetes].

    Science.gov (United States)

    Cobuz, C

    2009-01-01

    The connection between hypertension and diabetes emerges, in medical practice, from the current belief imposed by the European Society of Cardiology adding to the notion of total cardiovascular risk. An increse in the systolic blood pressure at night time is the first detectable manifestation of the regulation disorders of the blood pressure in type I diabetes. An early increase of the nocturnal blood pressure can play a key role in the detection of the evolution towards diabetic nephropathy. This modification can be a valuable potential marker for the diabetic nephropathy and could provide a reason for treating the high risk patients before the onset of microalbuminuria. The evaluation of the nefropathy risk in the early stages of type I diabetes using Ambulatory Blood Pressure Monitoring (ABPM) method offers the best premisses for preventing the progression of the disease towards microalbuminuria and hypertension.

  16. JACoW Automatic PID performance monitoring applied to LHC cryogenics

    CERN Document Server

    Bradu, Benjamin; Marti, Ruben; Tilaro, Filippo

    2018-01-01

    At CERN, the LHC (Large Hadron Collider) cryogenic system employs about 5000 PID (Proportional Integral Derivative) regulation loops distributed over the 27 km of the accelerator. Tuning all these regulation loops is a complex task and the systematic monitoring of them should be done in an automated way to be sure that the overall plant performance is improved by identifying the poorest performing PID controllers. It is nearly impossible to check the performance of a regulation loop with a classical threshold technique as the controlled variables could evolve in large operation ranges and the amount of data cannot be manually checked daily. This paper presents the adaptation and the application of an existing regulation indicator performance algorithm on the LHC cryogenic system and the different results obtained in the past year of operation. This technique is generic for any PID feedback control loop, it does not use any process model and needs only a few tuning parameters. The publication also describes th...

  17. Real-time algorithms for JET hard X-ray and gamma-ray profile monitor

    International Nuclear Information System (INIS)

    Fernandes, A.; Pereira, R.C.; Valcárcel, D.F.; Alves, D.; Carvalho, B.B.; Sousa, J.; Kiptily, V.; Correia, C.M.B.A.; Gonçalves, B.

    2014-01-01

    Highlights: • Real-time tools and mechanisms are required for data handling and machine control. • A new DAQ system, ATCA based, with embedded FPGAs, was installed at JET. • Different real-time algorithms were developed for FPGAs and MARTe application. • MARTe provides the interface to CODAS and to the JET real-time network. • The new DAQ system is capable to process and deliver data in real-time. - Abstract: The steady state operation with high energy content foreseen for future generation of fusion devices will necessarily demand dedicated real-time tools and mechanisms for data handling and machine control. Consequently, the real-time systems for those devices should be carefully selected and their capabilities previously established. The Joint European Torus (JET) is undertaking an enhancement program, which includes tests of relevant real-time tools for the International Thermonuclear Experimental Reactor (ITER), a key experiment for future fusion devices. In these enhancements a new Data AcQuisition (DAQ) system is included, with real-time processing capabilities, for the JET hard X-ray and gamma-ray profile monitor. The DAQ system is composed of dedicated digitizer modules with embedded Field Programmable Gate Array (FPGA) devices. The interface between the DAQ system, the JET control and data acquisition system and the JET real-time data network is provided by the Multithreaded Application Real-Time executor (MARTe). This paper describes the real-time algorithms, developed for both digitizers’ FPGAs and MARTe application, capable of meeting the DAQ real-time requirements. The new DAQ system, including the embedded real-time features, was commissioned during the 2012 experiments. Results achieved with these real-time algorithms during experiments are presented

  18. Real-time algorithms for JET hard X-ray and gamma-ray profile monitor

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, A., E-mail: anaf@ipfn.ist.utl.pt [Associação EURATOM/IST, Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade Técnica de Lisboa, 1049-001 Lisboa (Portugal); Pereira, R.C.; Valcárcel, D.F.; Alves, D.; Carvalho, B.B.; Sousa, J. [Associação EURATOM/IST, Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade Técnica de Lisboa, 1049-001 Lisboa (Portugal); Kiptily, V. [EURATOM/CCFE Fusion Association, Culham Centre for Fusion Energy, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Correia, C.M.B.A. [Centro de Instrumentação, Dept. de Física, Universidade de Coimbra, 3004-516 Coimbra (Portugal); Gonçalves, B. [Associação EURATOM/IST, Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade Técnica de Lisboa, 1049-001 Lisboa (Portugal)

    2014-03-15

    Highlights: • Real-time tools and mechanisms are required for data handling and machine control. • A new DAQ system, ATCA based, with embedded FPGAs, was installed at JET. • Different real-time algorithms were developed for FPGAs and MARTe application. • MARTe provides the interface to CODAS and to the JET real-time network. • The new DAQ system is capable to process and deliver data in real-time. - Abstract: The steady state operation with high energy content foreseen for future generation of fusion devices will necessarily demand dedicated real-time tools and mechanisms for data handling and machine control. Consequently, the real-time systems for those devices should be carefully selected and their capabilities previously established. The Joint European Torus (JET) is undertaking an enhancement program, which includes tests of relevant real-time tools for the International Thermonuclear Experimental Reactor (ITER), a key experiment for future fusion devices. In these enhancements a new Data AcQuisition (DAQ) system is included, with real-time processing capabilities, for the JET hard X-ray and gamma-ray profile monitor. The DAQ system is composed of dedicated digitizer modules with embedded Field Programmable Gate Array (FPGA) devices. The interface between the DAQ system, the JET control and data acquisition system and the JET real-time data network is provided by the Multithreaded Application Real-Time executor (MARTe). This paper describes the real-time algorithms, developed for both digitizers’ FPGAs and MARTe application, capable of meeting the DAQ real-time requirements. The new DAQ system, including the embedded real-time features, was commissioned during the 2012 experiments. Results achieved with these real-time algorithms during experiments are presented.

  19. Assessment of Machine Learning Algorithms for Automatic Benthic Cover Monitoring and Mapping Using Towed Underwater Video Camera and High-Resolution Satellite Images

    Directory of Open Access Journals (Sweden)

    Hassan Mohamed

    2018-05-01

    Full Text Available Benthic habitat monitoring is essential for many applications involving biodiversity, marine resource management, and the estimation of variations over temporal and spatial scales. Nevertheless, both automatic and semi-automatic analytical methods for deriving ecologically significant information from towed camera images are still limited. This study proposes a methodology that enables a high-resolution towed camera with a Global Navigation Satellite System (GNSS to adaptively monitor and map benthic habitats. First, the towed camera finishes a pre-programmed initial survey to collect benthic habitat videos, which can then be converted to geo-located benthic habitat images. Second, an expert labels a number of benthic habitat images to class habitats manually. Third, attributes for categorizing these images are extracted automatically using the Bag of Features (BOF algorithm. Fourth, benthic cover categories are detected automatically using Weighted Majority Voting (WMV ensembles for Support Vector Machines (SVM, K-Nearest Neighbor (K-NN, and Bagging (BAG classifiers. Fifth, WMV-trained ensembles can be used for categorizing more benthic cover images automatically. Finally, correctly categorized geo-located images can provide ground truth samples for benthic cover mapping using high-resolution satellite imagery. The proposed methodology was tested over Shiraho, Ishigaki Island, Japan, a heterogeneous coastal area. The WMV ensemble exhibited 89% overall accuracy for categorizing corals, sediments, seagrass, and algae species. Furthermore, the same WMV ensemble produced a benthic cover map using a Quickbird satellite image with 92.7% overall accuracy.

  20. Design of dual-road transportable portal monitoring system for visible light and gamma-ray imaging

    Science.gov (United States)

    Karnowski, Thomas P.; Cunningham, Mark F.; Goddard, James S.; Cheriyadat, Anil M.; Hornback, Donald E.; Fabris, Lorenzo; Kerekes, Ryan A.; Ziock, Klaus-Peter; Bradley, E. Craig; Chesser, J.; Marchant, W.

    2010-04-01

    The use of radiation sensors as portal monitors is increasing due to heightened concerns over the smuggling of fissile material. Transportable systems that can detect significant quantities of fissile material that might be present in vehicular traffic are of particular interest, especially if they can be rapidly deployed to different locations. To serve this application, we have constructed a rapid-deployment portal monitor that uses visible-light and gamma-ray imaging to allow simultaneous monitoring of multiple lanes of traffic from the side of a roadway. The system operation uses machine vision methods on the visible-light images to detect vehicles as they enter and exit the field of view and to measure their position in each frame. The visible-light and gamma-ray cameras are synchronized which allows the gamma-ray imager to harvest gamma-ray data specific to each vehicle, integrating its radiation signature for the entire time that it is in the field of view. Thus our system creates vehicle-specific radiation signatures and avoids source confusion problems that plague non-imaging approaches to the same problem. Our current prototype instrument was designed for measurement of upto five lanes of freeway traffic with a pair of instruments, one on either side of the roadway. Stereoscopic cameras are used with a third "alignment" camera for motion compensation and are mounted on a 50' deployable mast. In this paper we discuss the design considerations for the machine-vision system, the algorithms used for vehicle detection and position estimates, and the overall architecture of the system. We also discuss system calibration for rapid deployment. We conclude with notes on preliminary performance and deployment.

  1. Design of Dual-Road Transportable Portal Monitoring System for Visible Light and Gamma-Ray Imaging

    International Nuclear Information System (INIS)

    Karnowski, Thomas Paul; Cunningham, Mark F.; Goddard, James Samuel Jr.; Cheriyadat, Anil M.; Hornback, Donald Eric; Fabris, Lorenzo; Kerekes, Ryan A.; Ziock, Klaus-Peter; Bradley, Eric Craig; Chesser, Joel B.; Marchant, William

    2010-01-01

    The use of radiation sensors as portal monitors is increasing due to heightened concerns over the smuggling of fissile material. Transportable systems that can detect significant quantities of fissile material that might be present in vehicular traffic are of particular interest, especially if they can be rapidly deployed to different locations. To serve this application, we have constructed a rapid-deployment portal monitor that uses visible-light and gamma-ray imaging to allow simultaneous monitoring of multiple lanes of traffic from the side of a roadway. The system operation uses machine vision methods on the visible-light images to detect vehicles as they enter and exit the field of view and to measure their position in each frame. The visible-light and gamma-ray cameras are synchronized which allows the gamma-ray imager to harvest gamma-ray data specific to each vehicle, integrating its radiation signature for the entire time that it is in the field of view. Thus our system creates vehicle-specific radiation signatures and avoids source confusion problems that plague non-imaging approaches to the same problem. Our current prototype instrument was designed for measurement of upto five lanes of freeway traffic with a pair of instruments, one on either side of the roadway. Stereoscopic cameras are used with a third alignment camera for motion compensation and are mounted on a 50 deployable mast. In this paper we discuss the design considerations for the machine-vision system, the algorithms used for vehicle detection and position estimates, and the overall architecture of the system. We also discuss system calibration for rapid deployment. We conclude with notes on preliminary performance and deployment.

  2. Control and monitoring of electrical distribution grid using automatic meter reading systems

    Energy Technology Data Exchange (ETDEWEB)

    Venancio, Antonio [EDP, Lisboa (Portugal); Loureiro, Carlos [Edinfor - Sistemas Informaticos, Porto (Portugal); Costa, Joao [INESC, Lisboa (Portugal); Rodrigues, Antonio [INETI/DEL, Lisboa (Portugal); Antunes, Jose [EID, Monte da Caparica (Portugal)

    2000-07-01

    Technological innovation undertaken in recent years led to the introduction of electronics in metering apparatus. Deregulation of electricity markets around the world is pushing players to face competition. Supply companies are thus looking for ways to improve efficiency and gain Client's preference and confidence. Taking advantage of the technological innovation, AMR and Energy Management Systems can be a vital weapon in such a competitive scenario. Providing a wide range of services, from remote metering of electricity consumption to monitoring of supply quality, these systems can arm electrical utilities with necessary tools to improve supply efficiency and customer services. Following these trends, electrical utilities around Europe and all over the world are testing AMR and Energy Management solutions, and tailoring systems to their needs and modus operandi. Based on previous experience, gained with R&D work since 1991, EDP, the Portuguese Electrical Utility, is currently working on such systems and planning field trials in several scenarios. This paper presents EDP's approach towards AMR and Energy Management Systems, describing the system architecture and services; the way interoperability with existing commercial and technical management systems is planned; how technical solutions are planned to be tested and field trials are designed. Finally, some results of the ongoing projects will be presented.

  3. The continuous automatic monitoring network installed in Tuscany (Italy) since late 2002, to study earthquake precursory phenomena

    Science.gov (United States)

    Pierotti, Lisa; Cioni, Roberto

    2010-05-01

    Since late 2002, a continuous automatic monitoring network (CAMN) was designed, built and installed in Tuscany (Italy), in order to investigate and define the geochemical response of the aquifers to the local seismic activity. The purpose of the investigation was to identify eventual earthquake precursors. The CAMN is constituted by two groups of five measurement stations each. A first group has been installed in the Serchio and Magra graben (Garfagnana and Lunigiana Valleys, Northern Tuscany), while the second one, in the area of Mt. Amiata (Southern Tuscany), an extinct volcano. Garfagnana, Lunigiana and Mt. Amiata regions belong to the inner zone of the Northern Apennine fold-and-thrust belt. This zone has been involved in the post-collision extensional tectonics since the Upper Miocene-Pliocene. Such tectonic activity has produced horst and graben structures oriented from N-S to NW-SE that are transferred by NE-SW system. Both Garfagnana (Serchio graben) and Lunigiana (Magra graben) belong to the most inner sector of the belt where the seismic sources, responsible for the strongest earthquakes of the northern Apennine, are located (e.g. the M=6.5 earthquake of September 1920). The extensional processes in southern Tuscany have been accompanied by magmatic activity since the Upper Miocene, developing effusive and intrusive products traditionally attributed to the so-called Tuscan Magmatic Province. Mt. Amiata, whose magmatic activity ceased about 0.3 M.y. ago, belongs to the extensive Tyrrhenian sector that is characterized by high heat flow and crustal thinning. The whole zone is characterized by wide-spread but moderate seismicity (the maximum recorded magnitude has been 5.1 with epicentre in Piancastagnaio, 1919). The extensional regime in both the Garfagnana-Lunigiana and Mt. Amiata area is confirmed by the focal mechanisms of recent earthquakes. An essential phase of the monitoring activities has been the selection of suitable sites for the installation of

  4. High-Speed Neutron and Gamma Flux Sensor for Monitoring Surface Nuclear Reactors, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA needs compact nuclear reactors to power future bases on the moon and Mars. These reactors require robust automatic control systems using low mass, rapid...

  5. High-Speed Neutron and Gamma Flux Sensor for Monitoring Surface Nuclear Reactors, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA needs compact nuclear reactors to power future bases on the moon and/or Mars. These reactors require robust automatic control systems using low mass, rapid...

  6. Automatic Imitation in Rhythmical Actions: Kinematic Fidelity and the Effects of Compatibility, Delay, and Visual Monitoring

    Science.gov (United States)

    Eaves, Daniel L.; Turgeon, Martine; Vogt, Stefan

    2012-01-01

    We demonstrate that observation of everyday rhythmical actions biases subsequent motor execution of the same and of different actions, using a paradigm where the observed actions were irrelevant for action execution. The cycle time of the distractor actions was subtly manipulated across trials, and the cycle time of motor responses served as the main dependent measure. Although distractor frequencies reliably biased response cycle times, this imitation bias was only a small fraction of the modulations in distractor speed, as well as of the modulations produced when participants intentionally imitated the observed rhythms. Importantly, this bias was not only present for compatible actions, but was also found, though numerically reduced, when distractor and executed actions were different (e.g., tooth brushing vs. window wiping), or when the dominant plane of movement was different (horizontal vs. vertical). In addition, these effects were equally pronounced for execution at 0, 4, and 8 s after action observation, a finding that contrasts with the more short-lived effects reported in earlier studies. The imitation bias was also unaffected when vision of the hand was occluded during execution, indicating that this effect most likely resulted from visuomotor interactions during distractor observation, rather than from visual monitoring and guidance during execution. Finally, when the distractor was incompatible in both dimensions (action type and plane) the imitation bias was not reduced further, in an additive way, relative to the single-incompatible conditions. This points to a mechanism whereby the observed action’s impact on motor processing is generally reduced whenever this is not useful for motor planning. We interpret these findings in the framework of biased competition, where intended and distractor actions can be represented as competing and quasi-encapsulated sensorimotor streams. PMID:23071623

  7. Automatic imitation in rhythmical actions: kinematic fidelity and the effects of compatibility, delay, and visual monitoring.

    Directory of Open Access Journals (Sweden)

    Daniel L Eaves

    Full Text Available We demonstrate that observation of everyday rhythmical actions biases subsequent motor execution of the same and of different actions, using a paradigm where the observed actions were irrelevant for action execution. The cycle time of the distractor actions was subtly manipulated across trials, and the cycle time of motor responses served as the main dependent measure. Although distractor frequencies reliably biased response cycle times, this imitation bias was only a small fraction of the modulations in distractor speed, as well as of the modulations produced when participants intentionally imitated the observed rhythms. Importantly, this bias was not only present for compatible actions, but was also found, though numerically reduced, when distractor and executed actions were different (e.g., tooth brushing vs. window wiping, or when the dominant plane of movement was different (horizontal vs. vertical. In addition, these effects were equally pronounced for execution at 0, 4, and 8 s after action observation, a finding that contrasts with the more short-lived effects reported in earlier studies. The imitation bias was also unaffected when vision of the hand was occluded during execution, indicating that this effect most likely resulted from visuomotor interactions during distractor observation, rather than from visual monitoring and guidance during execution. Finally, when the distractor was incompatible in both dimensions (action type and plane the imitation bias was not reduced further, in an additive way, relative to the single-incompatible conditions. This points to a mechanism whereby the observed action's impact on motor processing is generally reduced whenever this is not useful for motor planning. We interpret these findings in the framework of biased competition, where intended and distractor actions can be represented as competing and quasi-encapsulated sensorimotor streams.

  8. Endotracheal tube cuff pressure monitoring during neurosurgery - Manual vs. automatic method

    Directory of Open Access Journals (Sweden)

    Mukul Kumar Jain

    2011-01-01

    Full Text Available Background: Inflation and assessment of the endotracheal tube cuff pressure is often not appreciated as a critical aspect of endotracheal intubation. Appropriate endotracheal tube cuff pressure, endotracheal intubation seals the airway to prevent aspiration and provides for positive-pressure ventilation without air leak. Materials and Methods: Correlations between manual methods of assessing the pressure by an experienced anesthesiologists and assessment with maintenance of the pressure within the normal range by the automated pressure controller device were studied in 100 patients divided into two groups. In Group M, endotracheal tube cuff was inflated manually by a trained anesthesiologist and checked for its pressure hourly by cuff pressure monitor till the end of surgery. In Group C, endotracheal tube cuff was inflated by automated cuff pressure controller and pressure was maintained at 25-cm H 2 O throughout the surgeries. Repeated measure ANOVA was applied. Results: Repeated measure ANOVA results showed that average of endotracheal tube cuff pressure of 50 patients taken at seven different points is significantly different (F-value: 171.102, P-value: 0.000. Bonferroni correction test shows that average of endotracheal tube cuff pressure in all six groups are significantly different from constant group (P = 0.000. No case of laryngomalacia, tracheomalacia, tracheal stenosis, tracheoesophageal fistula or aspiration pneumonitis was observed. Conclusions: Endotracheal tube cuff pressure was significantly high when endotracheal tube cuff was inflated manually. The known complications of high endotracheal tube cuff pressure can be avoided if the cuff pressure controller device is used and manual methods cannot be relied upon for keeping the pressure within the recommended levels.

  9. Evaluation of gamma radiation cumulative exposure monitoring system in the Nuclear Technology Development Center (CDTN) with thermoluminescent dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Domingues, Danieli S.; Barreto, Alberto A.; Siqueira, Gessilane M.; Oliveira, Eugênio M.; Silva, Robson L.; Belo, Luiz Cláudio M., E-mail: danielisilva@ymail.com, E-mail: aab@cdtn.br, E-mail: gessilane.siqueira@cdtn.br, E-mail: emo@cdtn.br, E-mail: rls@cdtn.br, E-mail: lcmb@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Cumulative exposure to gamma radiation is monitored at the Nuclear Technology Development Center - CDTN, located on the campus of the Federal University of Minas Gerais in Belo Horizonte - MG, since 1986. This monitoring is part of the Institution's Environmental Monitoring Program. The measurement is carried out through the use of thermoluminescent dosimeters (TLD's), which are placed in the perimeter of the CDTN property, distanced approximately 50 m each other, and at the air sampling stations, totaling 36 sampling points. The TLDs are positioned one meter from the ground, inside a PVC pipe where they remain exposed for a period of approximately three months. The objective of this work is to present and evaluate the results of this monitoring by investigating the dose values of gamma radiation (Dose Equivalent to Photons) obtained. Another important issue presented is about some failures identified in certain periods. There were problems with the sampling methodology and changes were proposed in the shelters to avoid contact of TLDs with excess moisture, which can compromise the results and the equipment of measurement of the thermoluminescence of crystals. The change was made at a sampling point and the results were compared with the historical data in the last 30 years. (author)

  10. Evaluation of gamma radiation cumulative exposure monitoring system in the Nuclear Technology Development Center (CDTN) with thermoluminescent dosimeters

    International Nuclear Information System (INIS)

    Domingues, Danieli S.; Barreto, Alberto A.; Siqueira, Gessilane M.; Oliveira, Eugênio M.; Silva, Robson L.; Belo, Luiz Cláudio M.

    2017-01-01

    Cumulative exposure to gamma radiation is monitored at the Nuclear Technology Development Center - CDTN, located on the campus of the Federal University of Minas Gerais in Belo Horizonte - MG, since 1986. This monitoring is part of the Institution's Environmental Monitoring Program. The measurement is carried out through the use of thermoluminescent dosimeters (TLD's), which are placed in the perimeter of the CDTN property, distanced approximately 50 m each other, and at the air sampling stations, totaling 36 sampling points. The TLDs are positioned one meter from the ground, inside a PVC pipe where they remain exposed for a period of approximately three months. The objective of this work is to present and evaluate the results of this monitoring by investigating the dose values of gamma radiation (Dose Equivalent to Photons) obtained. Another important issue presented is about some failures identified in certain periods. There were problems with the sampling methodology and changes were proposed in the shelters to avoid contact of TLDs with excess moisture, which can compromise the results and the equipment of measurement of the thermoluminescence of crystals. The change was made at a sampling point and the results were compared with the historical data in the last 30 years. (author)

  11. DO THE FERMI GAMMA-RAY BURST MONITOR AND SWIFT BURST ALERT TELESCOPE SEE THE SAME SHORT GAMMA-RAY BURSTS?

    International Nuclear Information System (INIS)

    Burns, Eric; Briggs, Michael S.; Connaughton, Valerie; Zhang, Bin-Bin; Lien, Amy; Goldstein, Adam; Pelassa, Veronique; Troja, Eleonora

    2016-01-01

    Compact binary system mergers are expected to generate gravitational radiation detectable by ground-based interferometers. A subset of these, the merger of a neutron star with another neutron star or a black hole, are also the most popular model for the production of short gamma-ray bursts (GRBs). The Swift Burst Alert Telescope (BAT) and the Fermi Gamma-ray Burst Monitor (GBM) trigger on short GRBs (SGRBs) at rates that reflect their relative sky exposures, with the BAT detecting 10 per year compared to about 45 for GBM. We examine the SGRB populations detected by Swift BAT and Fermi GBM. We find that the Swift BAT triggers on weaker SGRBs than Fermi GBM, providing they occur close to the center of the BAT field of view, and that the Fermi GBM SGRB detection threshold remains flatter across its field of view. Overall, these effects combine to give the instruments the same average sensitivity, and account for the SGRBs that trigger one instrument but not the other. We do not find any evidence that the BAT and GBM are detecting significantly different populations of SGRBs. Both instruments can detect untriggered SGRBs using ground searches seeded with time and position. The detection of SGRBs below the on-board triggering sensitivities of Swift BAT and Fermi GBM increases the possibility of detecting and localizing the electromagnetic counterparts of gravitational wave (GW) events seen by the new generation of GW detectors

  12. DO THE FERMI GAMMA-RAY BURST MONITOR AND SWIFT BURST ALERT TELESCOPE SEE THE SAME SHORT GAMMA-RAY BURSTS?

    Energy Technology Data Exchange (ETDEWEB)

    Burns, Eric; Briggs, Michael S. [University of Alabama in Huntsville, 320 Sparkman Drive, Huntsville, AL 35805 (United States); Connaughton, Valerie [Universities Space Research Association, Science and Technology Institute, 320 Sparkman Drive, Huntsville, AL 35805 (United States); Zhang, Bin-Bin [Center for Space Plasma and Aeronomic Research (CSPAR), University of Alabama in Huntsville, Huntsville, AL 35899 (United States); Lien, Amy [Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Goldstein, Adam [NASA Postdoctoral Program, Space Science Office, VP62, NASA/Marshall Space Flight Center, Huntsville, AL 35812 (United States); Pelassa, Veronique [Smithsonian Astrophysical Observatory, P.O. Box 97, Amado, AZ 85645 (United States); Troja, Eleonora, E-mail: eb0016@uah.edu [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States)

    2016-02-20

    Compact binary system mergers are expected to generate gravitational radiation detectable by ground-based interferometers. A subset of these, the merger of a neutron star with another neutron star or a black hole, are also the most popular model for the production of short gamma-ray bursts (GRBs). The Swift Burst Alert Telescope (BAT) and the Fermi Gamma-ray Burst Monitor (GBM) trigger on short GRBs (SGRBs) at rates that reflect their relative sky exposures, with the BAT detecting 10 per year compared to about 45 for GBM. We examine the SGRB populations detected by Swift BAT and Fermi GBM. We find that the Swift BAT triggers on weaker SGRBs than Fermi GBM, providing they occur close to the center of the BAT field of view, and that the Fermi GBM SGRB detection threshold remains flatter across its field of view. Overall, these effects combine to give the instruments the same average sensitivity, and account for the SGRBs that trigger one instrument but not the other. We do not find any evidence that the BAT and GBM are detecting significantly different populations of SGRBs. Both instruments can detect untriggered SGRBs using ground searches seeded with time and position. The detection of SGRBs below the on-board triggering sensitivities of Swift BAT and Fermi GBM increases the possibility of detecting and localizing the electromagnetic counterparts of gravitational wave (GW) events seen by the new generation of GW detectors.

  13. Overnight non-contact continuous vital signs monitoring using an intelligent automatic beam-steering Doppler sensor at 2.4 GHz.

    Science.gov (United States)

    Batchu, S; Narasimhachar, H; Mayeda, J C; Hall, T; Lopez, J; Nguyen, T; Banister, R E; Lie, D Y C

    2017-07-01

    Doppler-based non-contact vital signs (NCVS) sensors can monitor heart rates, respiration rates, and motions of patients without physically touching them. We have developed a novel single-board Doppler-based phased-array antenna NCVS biosensor system that can perform robust overnight continuous NCVS monitoring with intelligent automatic subject tracking and optimal beam steering algorithms. Our NCVS sensor achieved overnight continuous vital signs monitoring with an impressive heart-rate monitoring accuracy of over 94% (i.e., within ±5 Beats-Per-Minute vs. a reference sensor), analyzed from over 400,000 data points collected during each overnight monitoring period of ~ 6 hours at a distance of 1.75 meters. The data suggests our intelligent phased-array NCVS sensor can be very attractive for continuous monitoring of low-acuity patients.

  14. Use of a solar panel as a directionally sensitive large-area radiation monitor for direct and scattered x-rays and gamma-rays.

    Science.gov (United States)

    Abdul-Majid, S

    1987-01-01

    The characteristics of a 25.4 X 91 cm solar cell panel used as an x-ray and gamma-ray radiation monitor are presented. Applications for monitoring the primary x-ray beam are described at different values of operating currents and voltages as well as for directional dependence of scattered radiation. Other applications in gamma-ray radiography are also given. The detector showed linear response to both x-ray and gamma-ray exposures. The equipment is rigid, easy to use, relatively inexpensive and requires no power supply or any complex electronic equipment.

  15. A prototype of radioactive waste drum monitor by non-destructive assays using gamma spectrometry

    International Nuclear Information System (INIS)

    Thanh, Tran Thien; Trang, Hoang Thi Kieu; Chuong, Huynh Dinh; Nguyen, Vo Hoang; Tran, Le Bao; Tam, Hoang Duc; Tao, Chau Van

    2016-01-01

    In this work, segmented gamma scanning and the gamma emission tomography were used to locate unknown sources in a radioactive waste drum. The simulated detector response function and full energy peak efficiency are compared to corresponding experimental data and show about 5.3% difference for an energy ranging from 81 keV to 1332.5 keV for point sources. Computation of the corresponding activity is in good agreement with the true values. - Highlights: • Segmented gamma scanning and gamma emission tomography are used to locate point source in waste drums. • The PENELOPE software is used to compute the detection efficiency of the localized point source in the waste drum. • The activity of "1"3"7Cs and "6"0Co point source could be determined with an accuracy better than 10% for air and sand matrices.

  16. Thermal monitoring of hydrothermal activity by permanent infrared automatic stations: Results obtained at Solfatara di Pozzuoli, Campi Flegrei (Italy)

    Science.gov (United States)

    Chiodini, G.; Vilardo, G.; Augusti, V.; Granieri, D.; Caliro, S.; Minopoli, C.; Terranova, C.

    2007-12-01

    A permanent automatic infrared (IR) station was installed at Solfatara crater, the most active zone of Campi Flegrei caldera. After a positive in situ calibration of the IR camera, we analyze 2175 thermal IR images of the same scene from 2004 to 2007. The scene includes a portion of the steam heated hot soils of Solfatara. The experiment was initiated to detect and quantify temperature changes of the shallow thermal structure of a quiescent volcano such as Solfatara over long periods. Ambient temperature is the main parameter affecting IR temperatures, while air humidity and rain control image quality. A geometric correction of the images was necessary to remove the effects of slow movement of the camera. After a suitable correction the images give a reliable and detailed picture of the temperature changes, over the period October 2004 to January 2007, which suggests that origin of the changes were linked to anthropogenic activity, vegetation growth, and the increase of the flux of hydrothermal fluids in the area of the hottest fumaroles. Two positive temperature anomalies were registered after the occurrence of two seismic swarms which affected the hydrothermal system of Solfatara in October 2005 and October 2006. It is worth noting that these signs were detected in a system characterized by a low level of activity with respect to systems affected by real volcanic crisis where more spectacular results will be expected. Results of the experiment show that this kind of monitoring system can be a suitable tool for volcanic surveillance.

  17. Design and study of ultrasound-based automatic patient movement monitoring device for quantifying the intrafraction motion during teletherapy treatment.

    Science.gov (United States)

    Senthilkumar, S; Vinothraj, R

    2012-11-08

    The aim of the present study is to fabricate indigenously ultrasonic-based automatic patient's movement monitoring device (UPMMD) that immediately halts teletherapy treatment if a patient moves, claiming accurate field treatment. The device consists of circuit board, magnetic attachment device, LED indicator, speaker, and ultrasonic emitter and receiver, which are placed on either side of the treatment table. The ultrasonic emitter produces the ultrasound waves and the receiver accepts the signal from the patient. When the patient moves, the receiver activates the circuit, an audible warning sound will be produced in the treatment console room alerting the technologist to stop treatment. Simultaneously, the electrical circuit to the teletherapy machine will be interrupted and radiation will be halted. The device and alarm system can detect patient movements with a sensitivity of about 1 mm. Our results indicate that, in spite of its low-cost, low-power, high-precision, nonintrusive, light weight, reusable and simplicity features, UPMMD is highly sensitive and offers accurate measurements. Furthermore, UPMMD is patient-friendly and requires minimal user training. This study revealed that the device can prevent the patient's normal tissues from unnecessary radiation exposure, and also it is helpful to deliver the radiation to the correct tumor location. Using this alarming system the patient can be repositioned after interrupting the treatment machine manually. It also enables the technologists to do their work more efficiently.

  18. A Modification of Gamma Surveymeter Dosemeter 3007A for Monitoring Use Ethernet by PLC T100MD Series

    International Nuclear Information System (INIS)

    Ikhsan Shobari; Subchan, M.; Syahrudin Yusuf; Sutomo Budihardjo

    2010-01-01

    It has been modified a gamma surveymeter Dosemeter 3007A. The Surveymeter represents analogous surveymeter, so that an interface for data acquisition is required. Acquisition system from surveymeter is added to the voltage amplifier module from 0 - 200 mV to 0 - 5 V. This voltage value will represent of doses 0 - 5 mR/hour. Hereinafter the analogous signal 0 - 5 V as signal of input to peripheral of PLC T100MD series. Data in the form of processed analogous signal presented at local display of PLC. For long distance monitoring, data have been sent to a computer from PLC by ethernet. After this modification, the surveymeter can be used to monitor from long distance. By using Internet Service Provider, monitoring can be done at any time and any where as long as network internet is available. (author)

  19. Security and Hyper-accurate Positioning Monitoring with Automatic Dependent Surveillance-Broadcast (ADS-B), Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Lightning Ridge Technologies, LLC, working in collaboration with The Innovation Laboratory, Inc., extend Automatic Dependent Surveillance -- Broadcast (ADS-B) into a...

  20. Security and Hyper-accurate Positioning Monitoring with Automatic Dependent Surveillance-Broadcast (ADS-B), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Lightning Ridge Technologies, working in collaboration with The Innovation Laboratory, Inc., extend Automatic Dependent Surveillance Broadcast (ADS-B) into a safe,...

  1. An air-conditioning, ventilation and automatic ventilation monitoring and recording system constructed in an unsealed radioisotope laboratory. Energy-saving measures in Nagasaki University Radioisotope Center

    International Nuclear Information System (INIS)

    Takatsuji, Toshihiro; Yoshida, Masahiro; Takao, Hideaki; Okumura, Yutaka; Ooura, Tosinobu; Kotoura, Kazuki; Yamanaka, Yasushi; Yanagita, Hiroyoshi.

    1998-01-01

    We constructed an automatic operation system of air-conditioners and ventilators in a radiation controlled area to minimize electric consumption. The system operates the air-conditioner and the ventilator of each ventilation unit when someone is staying in rooms belonging to the unit based on information from an access control system to the controlled area and lighting switches in front of individual room. For understanding of operation conditions and confirmation of radioactive concentration in air lower than the legal limit at the ventilation stack, we also constructed an automatic ventilation monitoring and recording system, which makes complete operation records of each ventilator automatically. These systems enabled to achieve sharp energy-saving compatible with radiation protection. (author)

  2. Wide-Field Gamma-Spectrometer BDRG: GRB Monitor On-Board the Lomonosov Mission

    Science.gov (United States)

    Svertilov, S. I.; Panasyuk, M. I.; Bogomolov, V. V.; Amelushkin, A. M.; Barinova, V. O.; Galkin, V. I.; Iyudin, A. F.; Kuznetsova, E. A.; Prokhorov, A. V.; Petrov, V. L.; Rozhkov, G. V.; Yashin, I. V.; Gorbovskoy, E. S.; Lipunov, V. M.; Park, I. H.; Jeong, S.; Kim, M. B.

    2018-02-01

    The study of GRB prompt emissions (PE) is one of the main goals of the Lomonosov space mission. The payloads of the GRB monitor (BDRG) with the wide-field optical cameras (SHOK) and the ultra-fast flash observatory (UFFO) onboard the Lomonosov satellite are intended for the observation of GRBs, and in particular, their prompt emissions. The BDRG gamma-ray spectrometer is designed to obtain the temporal and spectral information of GRBs in the energy range of 10-3000 keV as well as to provide GRB triggers on several time scales (10 ms, 1 s and 20 s) for ground and space telescopes, including the UFFO and SHOK. The BDRG instrument consists of three identical detector boxes with axes shifted by 90° from each other. This configuration allows us to localize a GRB source in the sky with an accuracy of ˜ 2°. Each BDRG box contains a phoswich NaI(Tl)/CsI(Tl) scintillator detector. A thick CsI(Tl) crystal in size of \\varnothing 130 × 17 mm is placed underneath the NaI(Tl) as an active shield in the soft energy range and as the main detector in the hard energy range. The ratio of the CsI(Tl) to NaI(Tl) event rates at varying energies can be employed as an independent metric to distinguish legitimate GRB signals from false positives originating from electrons in near-Earth vicinities. The data from three detectors are collected in a BA BDRG information unit, which generates a GRB trigger and a set of data frames in output format. The scientific data output is ˜ 500 Mb per day, including ˜ 180 Mb of continuous data for events with durations in excess of 100 ms for 16 channels in each detector, detailed energy spectra, and sets of frames with ˜ 5 Mb of detailed information for each burst-like event. A number of pre-flight tests including those for the trigger algorithm and calibration were carried out to confirm the reliability of the BDRG for operation in space.

  3. Study of structure of marine specialist activity in an ergative system on monitoring and managing automatic control parameters of safe navigation process

    Directory of Open Access Journals (Sweden)

    Kholichev S. N.

    2016-12-01

    Full Text Available The study of structures' common features and dynamics of the technical object tuning circuit performing automatic adjustment of safe navigation options has been conducted for the first time in the theory of ergative systems. The research of the structure and process of ergative system functioning including an automatic control system with the option of safe navigation conditions has been fulfilled. The function of signals' selection performing optimal control law reconfiguration of the mentioned system has been given, and some sequence of marine specialist activities allowing solve the problem of navigation safety has been composed. The ergative system retargeted by the ship specialist has a two-tier hierarchy. The first level is an automatic control of the safe navigation parameter, and the second is the level of reconfiguration where the ship specialist changes the parameters of regulation act. The two-level hierarchical representation of the ergative navigation security settings management system makes it possible to introduce the concept of reconfiguration of regulation level as ship specialist activity which is to reduce the uncertainty in the environment in the operation of this layer. Such a reduction can be achieved as a result of exposure to the upper level associated with ideas of the ship specialist on the regulation of safe navigation parameters of the vessel on the lower level – the level of direct control automatic safe navigation option. As a result of studying the activities of the ship specialist in the ergative system on monitoring and managing automatic control parameters of safe navigation process it has been found that the main task of the ship specialist in the operation within the ergative system ensuring the navigation safety is to monitor the input and output of the automatic control system, decisions on the choice of reconfiguration laws regulating signal on the basis of information about deviations and the

  4. A Modern Automatic Chamber Technique as a Powerful Tool for CH4 and CO2 Flux Monitoring

    Science.gov (United States)

    Mastepanov, M.; Christensen, T. R.; Lund, M.; Pirk, N.

    2014-12-01

    A number of similar systems were used for monitoring of CH4 and CO2 exchange by the automatic chamber method in a range of different ecosystems. The measurements were carried out in northern Sweden (mountain birch forest near Abisko, 68°N, 2004-2010), southern Sweden (forest bog near Hässleholm, 56°N, 2007-2014), northeastern Greenland (arctic fen in Zackenberg valley, 74°N, 2005-2014), southwestern Greenland (fen near Nuuk, 64°N, 2007-2014), central Svalbard (arctic fen near Longyearbyen, 78°N, 2011-2014). Those in total 37 seasons of measurements delivered not only a large amount of valuable flux data, including a few novel findings (Mastepanov et al., Nature, 2008; Mastepanov et al., Biogeosciences, 2013), but also valuable experience with implementation of the automatic chamber technique using modern analytical instruments and computer technologies. A range of high resolution CH4 analysers (DLT-100, FMA, FGGA - Los Gatos Research), CO2 analyzers (EGM-4, SBA-4 - PP Systems; Li-820 - Li-Cor Biosciences), as well as Methane Carbon Isotope Analyzer (Los Gatos Research) has shown to be suitable for precise measurements of fluxes, from as low as 0.1 mg CH4 m-1 d-1 (wintertime measurements at Zackenberg, unpublished) to as high as 2.4 g CH4 m-1 d-1 (autumn burst 2007 at Zackenberg, Mastepanov et al., Nature, 2008). Some of these instruments had to be customized to accommodate 24/7 operation in harsh arctic conditions. In this presentation we will explain some of these customizations. High frequency of concentration measurements (1 Hz in most cases) provides a unique opportunity for quality control of flux calculations; on the other hand, this enormous amount of data can be analyzed only using highly automated algorithms. A specialized software package was developed and improved through the years of measurements and data processing. This software automates the data flow from raw concentration data of different instruments and sensors and various status records

  5. Research on self-powered detectors for gamma-ray monitoring

    International Nuclear Information System (INIS)

    Cho, S.W.; Lee, Y.J.

    1984-01-01

    Self-powered neutron detectors are used extensively in power reactors both for flux mapping and for power control and over-power protection, because of their small size, ruggedness and simplicity. But they have a few disadvantages such as high burn-up rate and background signal produced by the gamma-rays from the reactor itself. In order to overcome these disadvantages and to achieve a better understanding of gamma-ray effects of self-power detectors, a new type of self-powered detectors was designed and fabricated by the author,and experiments have carried out in the 10kCi sup(60)Co gamma irradiation facility in Korea Advanced Energy Research Institute. The configuration of the new type detectors is not of coaxial type but of paralled plate in order to obtain directional effects of gamma-ray incidence. Detector materials and dimensions are so chosen that the output current signal is large enough to be detected using some commercial measuring divice even at low dose rate and the contribution of the lead cable to the total signal is negligibly small. The results are 1)sensitivity is depended primarily on the materials of the insulator, 2)output signal has a good linearity to gamma dose rate, 3) response of detectors is prompt, but not perfect, 4) critical thickness for satusation of the output current is thinner than the range of photoelectron in the materials. (Author)

  6. Research on self-powered detectors for gamma-ray monitoring

    International Nuclear Information System (INIS)

    Cho, S.W.

    1983-01-01

    Self-powered neutron detectors are used extensively in power reactors both for flux mapping and for power control and over-power protection, because of their small size, ruggedness and simplicity. But they have a few disadvantages such as high burn-up rate and background signal produced by the gamma-rays from the reactor itself. In order to overcome these disadvantages and to achieve a better understanding of gamma-ray effects of self-powered detectors, a new type of self-powered detectors was designed and fabricated by the author, and experiments have been carried out in the 10kCi sup(60)Co gamma irradiation facility in Korea Advanced Energy Research Institute. The configuration of the new type detectors is not of coaxial type but of paralled plate in order to obtain directional effects of gamma-ray incidence. Detector materials and dimensions are so chosen that the output current signal is large enough to be detected using some commercial measuring divice even at low dose rate and the contribution of the lead cable to the totel signal is negligibly small. The results are 1) sensitivity is depended primarily on the materials of the insulator, 2) output signal has a good linearity to gamma dose rate, 3) response of detectors is prompt, but not perfect, 4) critical thickness for satusation of the output current is thinner than the range of photoelectron in the materials. (Author) πT

  7. Monitoring, controlling and safeguarding radiochemical streams at spent fuel reprocessing facilities with optical and gamma-ray spectroscopic methods

    International Nuclear Information System (INIS)

    Schwantes, J.M.; Bryan, S.A.; Orton, C.R.; Levitskaia, T.G.; Fraga, C.G.

    2013-01-01

    The International Atomic Energy Agency (IAEA) has established international safeguards standards for fissionable material at spent fuel reprocessing plants to ensure that significant quantities of weapons-usable nuclear material are not diverted from these facilities. For large throughput nuclear facilities, it is difficult to satisfy the IAEA safeguards accountancy goal for detection of abrupt diversion. Currently, methods to verify material control and accountancy (MCA) at these facilities require time-consuming and resource intensive destructive assay (DA). Leveraging new on-line non-destructive assay (NDA) process monitoring techniques in conjunction with the traditional and highly precise DA methods may provide an additional measure to nuclear material accountancy which would potentially result in a more timely, cost-effective and resource efficient means for safeguards verification at such facilities. By monitoring process control measurements (e.g. flowrates, temperatures, or concentrations of reagents, products or wastes), abnormal plant operations can be detected. Pacific Northwest National Laboratory (PNNL) is developing on-line NDA process monitoring technologies based upon gamma-ray and optical spectroscopic measurements to potentially reduce the time and resource burden associated with current techniques. The Multi-Isotope Process (MIP) Monitor uses gamma spectroscopy and multivariate analysis to identify off-normal conditions in process streams. The spectroscopic monitor continuously measures chemical compositions of the process streams including actinide metal ions (U, Pu, Np), selected fission products, and major stable flowsheet reagents using UV-Vis, Near IR and Raman spectroscopy. Multi-variate analysis is also applied to the optical measurements in order to quantify concentrations of analytes of interest within a complex array of radiochemical streams. This paper will provide an overview of these methods and reports on-going efforts to develop

  8. A carborne gamma-ray spectrometer system for natural radioactivity mapping and environmental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Grasty, R.L.; Cox, J.R. [Exploranium Ltd., Mississauga, Ontario (Canada)

    1997-12-31

    This paper summarizes the experience gained in the use of a carborne gamma-ray spectrometer system for mapping both natural and man-made radiation. Particular emphasis is placed on the calibration of the system for converting the gamma-ray measurements to ground concentrations of potassium, uranium and thorium and the activity of {sup 137}Cs. During the Finnish Emergency Response Exercise (Resume95), the carborne system was shown to be effective in mapping both natural and man-made radiation from {sup 137}Cs fallout and in locating radioactive sources. The application of the carborne system for mineral exploration is also demonstrated. (au). 10 refs.

  9. A carborne gamma-ray spectrometer system for natural radioactivity mapping and environmental monitoring

    International Nuclear Information System (INIS)

    Grasty, R.L.; Cox, J.R.

    1997-01-01

    This paper summarizes the experience gained in the use of a carborne gamma-ray spectrometer system for mapping both natural and man-made radiation. Particular emphasis is placed on the calibration of the system for converting the gamma-ray measurements to ground concentrations of potassium, uranium and thorium and the activity of 137 Cs. During the Finnish Emergency Response Exercise (Resume95), the carborne system was shown to be effective in mapping both natural and man-made radiation from 137 Cs fallout and in locating radioactive sources. The application of the carborne system for mineral exploration is also demonstrated. (au)

  10. A carborne gamma-ray spectrometer system for natural radioactivity mapping and environmental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Grasty, R L; Cox, J R [Exploranium Ltd., Mississauga, Ontario (Canada)

    1998-12-31

    This paper summarizes the experience gained in the use of a carborne gamma-ray spectrometer system for mapping both natural and man-made radiation. Particular emphasis is placed on the calibration of the system for converting the gamma-ray measurements to ground concentrations of potassium, uranium and thorium and the activity of {sup 137}Cs. During the Finnish Emergency Response Exercise (Resume95), the carborne system was shown to be effective in mapping both natural and man-made radiation from {sup 137}Cs fallout and in locating radioactive sources. The application of the carborne system for mineral exploration is also demonstrated. (au). 10 refs.

  11. Google Earth Visualizations of the Marine Automatic Identification System (AIS): Monitoring Ship Traffic in National Marine Sanctuaries

    Science.gov (United States)

    Schwehr, K.; Hatch, L.; Thompson, M.; Wiley, D.

    2007-12-01

    The Automatic Identification System (AIS) is a new technology that provides ship position reports with location, time, and identity information without human intervention from ships carrying the transponders to any receiver listening to the broadcasts. In collaboration with the USCG's Research and Development Center, NOAA's Stellwagen Bank National Marine Sanctuary (SBNMS) has installed 3 AIS receivers around Massachusetts Bay to monitor ship traffic transiting the sanctuary and surrounding waters. The SBNMS and the USCG also worked together propose the shifting the shipping lanes (termed the traffic separation scheme; TSS) that transit the sanctuary slightly to the north to reduce the probability of ship strikes of whales that frequent the sanctuary. Following approval by the United Nation's International Maritime Organization, AIS provided a means for NOAA to assess changes in the distribution of shipping traffic caused by formal change in the TSS effective July 1, 2007. However, there was no easy way to visualize this type of time series data. We have created a software package called noaadata-py to process the AIS ship reports and produce KML files for viewing in Google Earth. Ship tracks can be shown changing over time to allow the viewer to feel the motion of traffic through the sanctuary. The ship tracks can also be gridded to create ship traffic density reports for specified periods of time. The density is displayed as map draped on the sea surface or as vertical histogram columns. Additional visualizations such as bathymetry images, S57 nautical charts, and USCG Marine Information for Safety and Law Enforcement (MISLE) can be combined with the ship traffic visualizations to give a more complete picture of the maritime environment. AIS traffic analyses have the potential to give managers throughout NOAA's National Marine Sanctuaries an improved ability to assess the impacts of ship traffic on the marine resources they seek to protect. Viewing ship traffic

  12. Determination of perfluorobutane in rat blood by automatic headspace capillary gas chromatography and selected ion monitoring mass spectrometry.

    Science.gov (United States)

    Hvattum, E; Normann, P T; Oulie, I; Uran, S; Ringstad, O; Skotland, T

    2001-01-01

    A new contrast agent (Sonazoid; NC100100) for ultrasound imaging has been developed. It is an aqueous suspension of lipid stabilised perfluorobutane (PFB) gas microbubbles. An automatic headspace capillary gas-chromatographic mass spectrometric method using electron impact ionisation was developed for analysis of Sonazoid PFB in rat blood. The calibration standards were gaseous PFB dissolved in ethanol in the range of 0.5-5000 ng PFB. Fluorotrichloromethane (CFC 11) was used as an internal standard of the method and the MS detector was set to single ion monitoring of the base fragment ions of PFB (m/z 69 and 119) and CFC 11 (m/z 101). The calibration graph, made by plotting the peak area ratios of PFB (m/z 69) to CFC 11(m/z 101) against the amount of PFB, was fitted to a second-order polynomial equation with weighting 1/y2 and found to be reproducible. The limit of quantification of the method was set to 0.4 ng PFB. The between-day variation of the method was below 9.2% relative standard deviation (RSD) and the within-day variation of the method was below 7.6% RSD. The accuracy of the method, as compared to Coulter counter, was estimated by determination of PFB in samples where Sonazoid was added to saline and found to range from 91.5% to 105.2%. PFB, added as Sonazoid, was found to be stable for at least 7 months in rat blood samples when stored at -20 degrees C.

  13. Monitoring of gross alpha in the air and exposure gamma radiation on and around the coal fire power at Paiton

    International Nuclear Information System (INIS)

    Sutarman; Warsono, Asep

    1998-01-01

    Coal is burned in furnace operating at up to 1,700 o C in order to produce electrical energy and ash (bottom ash and fly-ash). The fly-ash is released to the atmosphere or environment around the coal fire power. Therefore, the environmental radioactivity monitoring should be carried out for gross alpha in the air and exposure gamma radiation. The measurement of gross alpha have been carried out using the alpha scintillation counter with the ZnS(Ag) detector, and measurement of gamma radiation using the high pressure ion chamber. The results obtained showed that the gross alpha in the air were the ranging from (7.1 ± 1,2) mBq m -3 to (12.2 ± 1.9) mBq m -3 and the exposure gamma radiation were (3.69 ± 0.11) μR/h to (9.55 ± 0.15) μR/h. The data were still lower than the limit of the maximum permissible concentration and annual intake for breathing but the gross alpha data were higher than in the nuclear installations. (authors)

  14. Monitoring and Microbiological Characteristics of Physico-chemical Dates of Canned Juice by Gamma Irradiation

    International Nuclear Information System (INIS)

    Arfa, Darine

    2008-01-01

    During this work, we are interested to the survey of the effect of gamma irradiation on the conservation of the juices of the dates. The results gotten of the microbiological and physico-chemical analysis done on the four samples, show the efficiency of the method for the conservation of the juices of the dates. (Author)

  15. Monitoring the radon flux from gold-mine dumps by gamma-ray mapping

    NARCIS (Netherlands)

    Lindsay, R; de Meijer, RJ; Maleka, PP; Newman, RT; Motlhabane, TGK; de Villiers, D

    The exhalation of radon from the large mine dumps at the gold mines in South Africa is a potential health hazard. Determination of radon fluxes from these dumpsites is problematic due to the scatter in the data in time and place and the cost involved in getting a representative sample. gamma-ray

  16. The applications of vehicle borne and ground gamma ray spectrometry in environmental radioactivity survey and monitoring: examples from the Philippines

    International Nuclear Information System (INIS)

    Reyes, R.Y.; Petrache, C.A.; Garcia, N.Q.; Tabora, E.U.; Juson, J.G.

    2002-01-01

    In the light of the nuclear development all over the world, there is an increasing global awareness on matters related to radioactivity and radioactive accidents. As such, the Philippine Nuclear Research Institute (PNRI) acquired through a technical cooperation project with the International Atomic Energy Agency the vehicle borne (car borne) and portable (ground) gamma ray, spectrometers. The objectives of this project were to establish environmental baseline information on the natural radioactivity of the entire country and to generate radioelement maps for geological mapping and mineral resource assessment. The purpose of this paper is to present the results of the different surveys including the methodologies and techniques conducted in the country using both spectrometers in effectively mapping natural and man-made sources of radiation. A pilot survey was successfully carried out over the small island of Marinduque (989 km 2 ) using the combined car borne and ground gamma ray spectrometric survey techniques. This was in preparation of the planned nationwide survey using this approach. Highlight of this study was the production of the first natural radioactivity maps within the country. Interestingly, these maps closely reflect the local geology of Marinduque Island. Car borne gamma ray spectrometric surveys were likewise undertaken at the former US naval base in Subic and US airforce base in Clark. This was due to mounting public concern over the presence of possible radioactive contamination or materials left behind by the US military forces in these bases. Results using the gamma-ray spectrum ratio technique indicated the absence of man-made sources of radiation in areas monitored within the two bases. A sizeable part of Metro Manila, the capital of the Philippines, has also been covered by the car borne survey. Results discovered an area with high measurements of thorium. The radiation source is coming from an establishment that uses thorium nitrate in

  17. Air gamma spectrometry in the radiation monitoring situation of Army of the Czech Republic

    International Nuclear Information System (INIS)

    Pavlik, J.; Sladek, P.

    2011-01-01

    In this poster authors deal with aerial radiation monitoring of territory of the Czech Republic. Army Radiation Monitoring Network (ARMS) are selected folder whirlwind Army of the Czech Republic (ACR), that are destined for the tasks of the National Radiation Monitoring Network (CRMS).

  18. Development of an omnidirectional gamma-ray imaging Compton camera for low-radiation-level environmental monitoring

    Science.gov (United States)

    Watanabe, Takara; Enomoto, Ryoji; Muraishi, Hiroshi; Katagiri, Hideaki; Kagaya, Mika; Fukushi, Masahiro; Kano, Daisuke; Satoh, Wataru; Takeda, Tohoru; Tanaka, Manobu M.; Tanaka, Souichi; Uchida, Tomohisa; Wada, Kiyoto; Wakamatsu, Ryo

    2018-02-01

    We have developed an omnidirectional gamma-ray imaging Compton camera for environmental monitoring at low levels of radiation. The camera consisted of only six CsI(Tl) scintillator cubes of 3.5 cm, each of which was readout by super-bialkali photo-multiplier tubes (PMTs). Our camera enables the visualization of the position of gamma-ray sources in all directions (∼4π sr) over a wide energy range between 300 and 1400 keV. The angular resolution (σ) was found to be ∼11°, which was realized using an image-sharpening technique. A high detection efficiency of 18 cps/(µSv/h) for 511 keV (1.6 cps/MBq at 1 m) was achieved, indicating the capability of this camera to visualize hotspots in areas with low-radiation-level contamination from the order of µSv/h to natural background levels. Our proposed technique can be easily used as a low-radiation-level imaging monitor in radiation control areas, such as medical and accelerator facilities.

  19. Automatic Photoelectric Telescope Service

    International Nuclear Information System (INIS)

    Genet, R.M.; Boyd, L.J.; Kissell, K.E.; Crawford, D.L.; Hall, D.S.; BDM Corp., McLean, VA; Kitt Peak National Observatory, Tucson, AZ; Dyer Observatory, Nashville, TN)

    1987-01-01

    Automatic observatories have the potential of gathering sizable amounts of high-quality astronomical data at low cost. The Automatic Photoelectric Telescope Service (APT Service) has realized this potential and is routinely making photometric observations of a large number of variable stars. However, without observers to provide on-site monitoring, it was necessary to incorporate special quality checks into the operation of the APT Service at its multiple automatic telescope installation on Mount Hopkins. 18 references

  20. Effects of Display Gamma and Illuminant on the Appearance of Colours Viewed on LCD Monitors

    Directory of Open Access Journals (Sweden)

    Dragoljub Novakovic

    2009-11-01

    Full Text Available The CIECAM02 colour appearance model was developed to allow prediction of accurate colour appearance under various viewing conditions. In this study, a software module, based on mathematical transformations of the CIECAM02 model, was designed and implemented. Unlike the previous software modules, which were allowing use of only a limited choice of common standardized icc display profiles, the developed module also allows the use of optimized profiles created by the user. This paper presents prediction of the appearance of test images with assigned different display profiles after changing illuminant. The two used optimized profiles, created by software characterization of specific lcd display, have a different display gamma value (1.8 and 2.2.  It is observed that, after changing the initial cie D50 to a higher colour temperature illuminant (D65,  the colours of  images will be shifted to the blue hues, and, in the case of illuminant temperature less than D50 (A and F11,  to yellow hues. It is also observed that the intensity of colour shifts in the simulated images with associated profiles which have different gamma value will be significantly different, which implies that the icc display profile and display gamma value have the great impact on the prediction of the accurate colour appearance under various viewing conditions.

  1. Improved extrinsic polymer optical fiber sensors for gamma-ray monitoring in radioprotection applications

    Science.gov (United States)

    de Andrés, A. I.; Esteban, Ó.; Embid, M.

    2017-08-01

    Gamma radiation detection in the range of 662 keV, the reference for environmental protection, is done through extrinsic optical fiber sensors. The fluorescence rendered by an inorganic scintillator when irradiated with such gamma rays is gathered by a modified polymer optical fiber tip. This modification increases the recorded signal when compared with plain unaltered fiber. Two fiber tip modification are then compared in terms of light gathering capability. A chemically etched fiber, in which the cladding and part of the core are removed, and a tapered fiber in which the core-cladding structure is kept. Both structures are comparable in length and final diameter, and show linear response in the tested range up to 2 Gy/h air Kerma rate. The etched fiber shows a higher slope than the tapered one, although both improve the signal gathered by a plain fiber tip. The easy fabrication and handling of the reported transducers, together with the improved signal gathering, allow to reduce the overall system budget with the use of low-cost optoelectronics in the detection stage. This offers a significant improvement for surveillance systems in radioprotection applications, in which presence of gamma radiation coming out accidental leakage or spurious sources activity is the main target.

  2. Monitoring of Natural Soil Radioactivity with Portable Gamma-Ray Spectrometers

    DEFF Research Database (Denmark)

    Bøtter-Jensen, Lars; Løvborg, Leif; Kirkegaard, Peter

    1979-01-01

    Two portable NaI(Tl) spectrometers with four energy windows were used for the recording of gamma-ray counts over soil and rock of differing natural radioactivity. The exposure rates at the field sites were simultaneously measured with a high-pressure argon ionization chamber. Background measureme......Two portable NaI(Tl) spectrometers with four energy windows were used for the recording of gamma-ray counts over soil and rock of differing natural radioactivity. The exposure rates at the field sites were simultaneously measured with a high-pressure argon ionization chamber. Background...... measurements at sea were carried out in order to estimate the non-terrestrial contributions to the instrument readings. Counts recorded in the three high-energy windows of the spectrometers were converted into radiometrically equivalent concentrations of thorium, uranium, and potassium in the ground. Large....... The theoretical exposure rates deducible from the experimental radioelement concentrations at the field sites were in good agreement both with the ionization-chamber readings (corrected for cosmic-ray background) and with the exposure rates measured by total gamma-ray counting. From this and other results...

  3. Model H-90A gamma-ray spectrometer with microcomputer

    International Nuclear Information System (INIS)

    Zhang Biao; Dong Chen; Zhao Zhiming

    1994-11-01

    Model H-90A is a 4-channel differential Gamma-ray spectrometer with microcomputer. It consists of a console and NaI(TL) crystal detector with a diameter of φ75 mm x 75 mm. The instrument has excellent performance such as automatic spectrum stabilization, automatic regular timing measurement and automatic calculation of uranium, thorium and potassium contents and their ratios. Original data can be manually and automatically stored. The instrument is provided with shut down supply protective device, reading out can be repeated or be further processed through RS-232 interface output in the case of connection with computer. The working command is inputted by 'soft key' and performed by slice microcomputer automatically through software. It can be used not only in radioactive geological mapping, geochemical research and rapid field assay of radioactive elements in mineral and rock samples, but also for exploration and reconnaissance survey for uranium, thorium, potassium and seeking gold, as well as environmental monitoring

  4. Gems [Guardian Environmental Monitoring System] keeps a continuous eye on gamma-ray emissions

    International Nuclear Information System (INIS)

    Gould, J.L.

    1986-01-01

    To enable electricity utilities to demonstrate the very low release rates of radiation emitters from nuclear power stations into the environment, Gems (Guardian Environmental Monitoring System) has been developed. The units have been installed as emergency plume monitors round the perimeter of several British power stations and can be connected to windspeed and direction instrumentation to provide on-line activity release data. (UK)

  5. Gamma-ray spectroscopy applications in radiation control and environmental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Manushev, B [Sofia Univ. (Bulgaria). Fizicheski Fakultet; Koleva, K [National Metrology Centre, Sofia (Bulgaria)

    1996-12-31

    A method for stabilization of gamma-ray spectrometers energy calibration is proposed. It is based on recalibration of the spectrum by numerical filtration. The possibility of efficiency auto-calibration is considered in the case when a reference source with appropriate shape is unavailable. The method is tested by estimation of the effective thickness of a lead plate (self-absorption). Potential applications include the evaluation of surface pollution infiltration depth as well as the development of pure beta sources (e.g. Sr-90) using the registration of their Bremsstrahlung. 6 refs.

  6. Observation of radioactive background in the OSO-7 gamma ray monitor

    International Nuclear Information System (INIS)

    Dunphy, P.P.; Forrest, D.J.; Chupp, E.L.; Dyer, C.S.

    1975-01-01

    The counting rate, covering the energy range 0.3-10 MeV, during a sixteen month period (October 1971-December 1972) was considerably higher than expected from balloon data. Dyer et al. have shown the importance of activation in satellites for diffuse gamma flux measurements. The OSO-7 spectra exhibit strong, complex line structure, especially between 400 keV and 900 keV, and several identifications can be made consistent with the model of Dyer et al. We present here the spectral structure and time variations. (orig./WB) [de

  7. INTERFEROMETRIC MONITORING OF GAMMA-RAY BRIGHT AGNs. I. THE RESULTS OF SINGLE-EPOCH MULTIFREQUENCY OBSERVATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang-Sung; Wajima, Kiyoaki; Algaba, Juan-Carlos; Zhao, Guang-Yao; Hodgson, Jeffrey A.; Byun, Do-Young; Kang, Sincheol; Kim, Soon-Wook; Kino, Motoki [Korea Astronomy and Space Science Institute, 776 Daedeok-daero, Yuseong-gu, Daejeon 34055 (Korea, Republic of); Kim, Dae-Won; Park, Jongho; Kim, Jae-Young; Trippe, Sascha [Department of Physics and Astronomy, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul 08826 (Korea, Republic of); Miyazaki, Atsushi [Japan Space Forum, 3-2-1, Kandasurugadai, Chiyoda-ku, Tokyo 101-0062 Japan (Japan); Kim, Jeong-Sook, E-mail: sslee@kasi.re.kr [National Astronomical Observatory of Japan, 2211 Osawa, Mitaka, Tokyo 1818588 (Japan)

    2016-11-01

    We present results of single-epoch very long baseline interferometry (VLBI) observations of gamma-ray bright active galactic nuclei (AGNs) using the Korean VLBI Network (KVN) at the 22, 43, 86, and 129 GHz bands, which are part of a KVN key science program, Interferometric Monitoring of Gamma-Ray Bright AGNs. We selected a total of 34 radio-loud AGNs of which 30 sources are gamma-ray bright AGNs with flux densities of >6 × 10{sup −10} ph cm{sup −2} s{sup −1}. Single-epoch multifrequency VLBI observations of the target sources were conducted during a 24 hr session on 2013 November 19 and 20. All observed sources were detected and imaged at all frequency bands, with or without a frequency phase transfer technique, which enabled the imaging of 12 faint sources at 129 GHz, except for one source. Many of the target sources are resolved on milliarcsecond scales, yielding a core-jet structure, with the VLBI core dominating the synchrotron emission on a milliarcsecond scale. CLEAN flux densities of the target sources are 0.43–28 Jy, 0.32–21 Jy, 0.18–11 Jy, and 0.35–8.0 Jy in the 22, 43, 86, and 129 GHz bands, respectively. Spectra of the target sources become steeper at higher frequency, with spectral index means of −0.40, −0.62, and −1.00 in the 22–43 GHz, 43–86 GHz and 86–129 GHz bands, respectively, implying that the target sources become optically thin at higher frequencies (e.g., 86–129 GHz).

  8. Contaminants and nutrients in variable sea areas (Canvas). Application of automatic monitoring stations in the German marine environment

    International Nuclear Information System (INIS)

    Nies, H.; Bruegge, B.; Sterzenbach, D.; Knauth, H.D.; Schroeder, F.

    1999-01-01

    Permanent observation of parameters at sea stations can only be obtained by automatic sampling. The MERMAID technique developed in former projects provides a possibility to run automatic stations within the German MARNET measuring stations to obtain data on nutrients concentration on line and to collect organic micropollutants and the radionuclide 137 Cs by solid phase extraction from seawater and subsequent analysis in the laboratory. The BSH MARNET consists of ten stations located in the German Bight sector of the North Sea and the western Baltic. First results from the time series of nutrient and organic micropollutant concentrations has been presented

  9. Monitoring of the internal contamination of occupationally exposure personnel in services of nuclear medicine through the use of gamma cameras

    International Nuclear Information System (INIS)

    Teran, M.; Paolino, A.; Savio, E.; Hermida, J.C.; Dantas, B.M.

    2006-01-01

    The radionuclides incorporation can happen as a result of diverse activities; these include the work associated with the different stadiums of the nuclear fuel cycle, the use of radioactive sources in medicine, the scientific research, the agriculture and the industry. In Uruguay the main activities linked to the manipulation of open sources correspond those of Nuclear Medicine and from 2004, in the mark of the Project Arcal RLA 049 and being based on the Safety Guides of the IAEA it is implementing a program of internal monitoring in combined form the Nuclear Medicine Center of the Hospital of and the Radiochemistry class of the Faculty of Chemistry. In accordance with the publication of the ICRP 75 the emphasis of any monitoring program should be in the formal study of the doses in the workers to who are considered commendable of to receive in routine form an outstanding fraction of the dose limits or who work in areas where the exposures can be significant in the accident event. From April 2004, to the date has started a pilot plan by means of in that were established appropriate conditions of procedures and of safety in a reduced group of workers of the Nuclear Medicine area. In that period the first work limits, equipment adjustment, calibrations and registration systems were determined. The monitoring system implemented until the moment is carried out with a thyroid caption equipment. However these measurements are carried out in the university hospital embracing 40% of the involved workers of our country, with the purpose of reaching the covering of the biggest quantity of occupationally exposed personnel of private clinics. Also it was developed a new work proposal that allows to have an alternative measure method, in the event of not having the equipment habitually used. Among the conclusions of this work are that for the before exposed are considered the measure conditions but appropriate the following ones: Gamma Camera without collimator; Measurement

  10. Use of dual-head gamma camera in radionuclide internal contamination monitoring on radiation workers from a nuclear medicine department

    International Nuclear Information System (INIS)

    Rodriguez-Laguna, A.; Brandan, M.E.

    2008-01-01

    As a part of an internal dosimetry program that is performed at the Mexican National Institute of Cancerology - Nuclear Medicine Department, in the present work we suggest a procedure for the routinely monitoring of internal contamination on radiation workers and nuclear medicine staff. The procedure is based on the identification and quantification of contaminating radionuclides in human body by using a dual-head whole-body gamma camera. The results have shown that the procedures described in this study can be used to implement a method to quantify minimal accumulated activity in the main human organs to evaluate internal contamination with radionuclides. The high sensitivity of the uncollimated gamma camera is advantageous for the routinely detection and identification of small activities of internal contamination. But, the null spatial resolution makes impossible the definition of contaminated region of interest. Then, the use of collimators is necessary to the quantification of incorporated radionuclides activities in the main human organs and for the internal doses assessment. (author)

  11. Sentinel-1 automatic processing chain for volcanic and seismic areas monitoring within the Geohazards Exploitation Platform (GEP)

    Science.gov (United States)

    De Luca, Claudio; Zinno, Ivana; Manunta, Michele; Lanari, Riccardo; Casu, Francesco

    2016-04-01

    The microwave remote sensing scenario is rapidly evolving through development of new sensor technology for Earth Observation (EO). In particular, Sentinel-1A (S1A) is the first of a sensors' constellation designed to provide a satellite data stream for the Copernicus European program. Sentinel-1A has been specifically designed to provide, over land, Differential Interferometric Synthetic Aperture Radar (DInSAR) products to analyze and investigate Earth's surface displacements. S1A peculiarities include wide ground coverage (250 km of swath), C-band operational frequency and short revisit time (that will reduce from 12 to 6 days when the twin system Sentinel-1B will be placed in orbit during 2016). Such characteristics, together with the global coverage acquisition policy, make the Sentinel-1 constellation to be extremely suitable for volcanic and seismic areas studying and monitoring worldwide, thus allowing the generation of both ground displacement information with increasing rapidity and new geological understanding. The main acquisition mode over land is the so called Interferometric Wide Swath (IWS) that is based on the Terrain Observation by Progressive Scans (TOPS) technique and that guarantees the mentioned S1A large coverage characteristics at expense of a not trivial interferometric processing. Moreover, the satellite spatial coverage and the reduced revisit time will lead to an exponential increase of the data archives that, after the launch of Sentine-1B, will reach about 3TB per day. Therefore, the EO scientific community needs from the one hand automated and effective DInSAR tools able to address the S1A processing complexity, and from the other hand the computing and storage capacities to face out the expected large amount of data. Then, it is becoming more crucial to move processors and tools close to the satellite archives, being not efficient anymore the approach of downloading and processing data with in-house computing facilities. To address

  12. A round periodization monitoring of gamma rays in the environment around Daya Bay Nuclear Power Plant

    International Nuclear Information System (INIS)

    Su Qiong; Song Haiqing

    1992-12-01

    The materials of environmental background radiations around a NPP (nuclear power Plant) to be constructed is an important part in the environment effect evaluation report before its operation. The sampling and preparation of samples of air dust and rain water, measuring equipment and analytical method of gamma radionuclides, and a discussion on obtained results in the second round investigation of the two investigations are presented. Comparing with the first round investigation, the sampling places are expanded and improved, especially, a complete and satisfactory data are obtained due to the combination of anti-coincidence shield/anti-Compton HPGe ultra-low γ spectrometer and common HPGe spectrometer. These provides more systematic material to the environmental science research

  13. A new programmable zone dosimeter for operational monitoring and measurement of external gamma radiation

    International Nuclear Information System (INIS)

    Toledo Acosta, Rene; Arteche Diaz, Raul; Mesa Perez, Guillermo; Fernandez Llanez, Sandra; Tamayo Garcia, Jose Antonio; Alonso Villanueva, Gilberto

    2010-01-01

    The detection and the measurement of the nuclear radiations have turn into an important item in the nuclear detectors application and specifically the Geiger Muller ones. Coming from theirs high detection sensibility, robust construction and relative simplicity of the associated circuit, the Geiger Tubes are still one of the most widely used detectors in all the application areas regarding physics and nuclear investigations A new design instrument is presented to be measures the ambient dose of external (gamma) radiation since 10 mSv/h. It consists of three elements: Geiger-Muller detector, the electronic board for the acquisition and control and the application software. The instrument communicates trough a USB interface to the Personal Computer only for adjust calibration parameters. The software was developed in the C programming language using PICC4, 08 compilers. (author)

  14. Automatic Web-Based, Radio-Network System To Monitor And Control Equipment For Investigating Gas Flux At Water - Air Interfaces

    Science.gov (United States)

    Duc, N. T.; Silverstein, S.; Wik, M.; Beckman, P.; Crill, P. M.; Bastviken, D.; Varner, R. K.

    2015-12-01

    Aquatic ecosystems are major sources of greenhouse gases (GHG). Robust measurements of natural GHG emissions are vital for evaluating regional to global carbon budgets and for assessing climate feedbacks on natural emissions to improve climate models. Diffusive and ebullitive (bubble) transport are two major pathways of gas release from surface waters. To capture the high temporal variability of these fluxes in a well-defined footprint, we designed and built an inexpensive automatic device that includes an easily mobile diffusive flux chamber and a bubble counter, all in one. Besides a function of automatically collecting gas samples for subsequent various analyses in the laboratory, this device utilizes low cost CO2 sensor (SenseAir, Sweden) and CH4 sensor (Figaro, Japan) to measure GHG fluxes. To measure the spatial variability of emissions, each of the devices is equipped with an XBee module to enable a local radio communication DigiMesh network for time synchronization and data readout at a server-controller station on the lakeshore. Software of this server-controller is operated on a low cost Raspberry Pi computer which has a 3G connection for remote monitoring - controlling functions from anywhere in the world. From field studies in Abisko, Sweden in summer 2014 and 2015, the system has resulted in measurements of GHG fluxes comparable to manual methods. In addition, the deployments have shown the advantage of a low cost automatic network system to study GHG fluxes on lakes in remote locations.

  15. Environmental monitoring (operational period) of the uranium enrichment facility Almirante Alvaro Alberto. Quadrimonthly report of gamma spectroscopy measurements: march to june 1988

    International Nuclear Information System (INIS)

    Venturini, L.; Pecequilo, B.R.S.

    1990-02-01

    In this report we present the assessment of the environmental monitoring radiation levels during the operation period of the Uranium Enrichment Facility Almirante Alvaro Alberto from March to July 1988. The purpose was achieved by sampling and analyzing using gamma spectrometry, water and terrestrial and biological indicators. (author) [pt

  16. Environmental gamma radiation monitoring system with a large volume air ionization chamber

    International Nuclear Information System (INIS)

    Duftschmid, K.E.; Strachotinsky, C.; Witzani, J.

    1986-01-01

    An improved environmental monitoring system has been designed and tested consisting of an ionization chamber with 120 l sensitive volume, operated at atmospheric pressure, and a commercial electrometer amplifier with digital voltmeter. The system is controlled by a desk calculator with printer for automated operation and calculation of dose and doserate. The ionization chamber provides superior dosimetric performance as compared to usual GM-counters and high pressure chambers. The system has been field-tested during the 'European Intercomparison Programme for Environmental Monitoring Instruments' organized by the Commission of the European Communities. (Author)

  17. Autonomous long-term gamma-spectrometric monitoring of submarine groundwater discharge trends in Hawaii

    Czech Academy of Sciences Publication Activity Database

    Dulai, H.; Kameník, Jan; Waters, C. A.; Kennedy, J.; Babinec, J.; Jolly, J.; Williamson, M.

    2016-01-01

    Roč. 307, č. 3 (2016), s. 1865-1870 ISSN 0236-5731. [10th International Conference on Methods and Applications of Radioanalytical Chemistry (MARC). Kailua Kona, 12.04.2015-17.04.2015] Institutional support: RVO:61389005 Keywords : submarine groundwater discharge * long-term SGD monitoring * underwater gammaspectrometry Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 1.282, year: 2016

  18. Automatic earthquake detection and classification with continuous hidden Markov models: a possible tool for monitoring Las Canadas caldera in Tenerife

    Energy Technology Data Exchange (ETDEWEB)

    Beyreuther, Moritz; Wassermann, Joachim [Department of Earth and Environmental Sciences (Geophys. Observatory), Ludwig Maximilians Universitaet Muenchen, D-80333 (Germany); Carniel, Roberto [Dipartimento di Georisorse e Territorio Universitat Degli Studi di Udine, I-33100 (Italy)], E-mail: roberto.carniel@uniud.it

    2008-10-01

    A possible interaction of (volcano-) tectonic earthquakes with the continuous seismic noise recorded in the volcanic island of Tenerife was recently suggested, but existing catalogues seem to be far from being self consistent, calling for the development of automatic detection and classification algorithms. In this work we propose the adoption of a methodology based on Hidden Markov Models (HMMs), widely used already in other fields, such as speech classification.

  19. The role of interferon gamma release assays in the monitoring of response to anti-tuberculosis treatment in children.

    Science.gov (United States)

    Shaik, Junaid; Pillay, Manormoney; Jeena, Prakash

    2014-09-01

    Successful control of childhood TB requires early diagnosis, effective chemotherapy and a method of evaluating the response to therapy. Identification of suitable biomarkers that predict the response to anti-TB therapy may allow the duration of treatment to be shortened. The majority of biomarker studies in paediatric TB have focused on the role of T cell-based interferon-gamma (IFN-γ) release assays (IGRAs) in the diagnosis of either latent or active disease. Little has been published on the role of IGRAs in the monitoring response to therapy in children. We reviewed the available literature to ascertain the value of IGRAs in the monitoring of response to anti-TB therapy in children. We explored the results of the few studies that have investigated the role of IGRAs as markers of response to anti-TB treatment in children. We conclude that the role of IGRAs as surrogate markers appears promising. Robust clinical trials are, however, needed to entrench the value of IGRAs as surrogate biomarkers of response to anti-TB therapy in children. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Monitoring of blood-10B concentration for boron neutron capture therapy using prompt gamma-ray analysis

    International Nuclear Information System (INIS)

    Raaijmakers, C.P.J.; Konijnenberg, M.W.; Dewit, L.; Mijnheer, B.J.; Haritz, D.; Huiskamp, R.; Philipp, K.; Siefert, A.; Stecher-Rasmussen, F.

    1995-01-01

    The aim of the present study was to monitor the blood- 10 B concentration of laboratory dogs receiving boron neutron capture therapy, in order to obtain optimal agreement between prescribed and actual dose. A prompt gamma-ray analysis system was developed for this purpose at the High Flux Reactor in Petten. The technique was compared with inductively coupled plasma-atomic emission spectrometry and showed good agreement. A substantial variation in 10 B clearance pattern after administration of borocaptate sodium was found between the different dogs. Consequently, the irradiation commencement was adjusted to the individually determined boron elimination curve. Mean blood- 10 B concentratios during irradiation of 25.8±2.2 μg/g (1 SD, n=18) and 49.3±5.3 μg/g (1 SD, n=17) were obtained for intended concentrations of 25 μg/g and 50 μg/g, respectively. These variations are a factor of two smaller than irradiations performed at a uniform post-infusion irradiation starting time. Such a careful bolld- 10 B monitoring procedure is a prerequisite for accurately obtaining such steep dose-response curves as observed during the dog study. (orig.)

  1. Statistical pixelwise inference models for planar data analysis: an application to gamma-camera uniformity monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Kalemis, A [Joint Department of Physics, Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Downs Road, Sutton, Surrey SM2 5PT (United Kingdom); Bailey, D L [Department of Nuclear Medicine, Royal North Shore Hospital, St Leonards, NSW 2065 (Australia); Flower, M A [Joint Department of Physics, Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Downs Road, Sutton, Surrey SM2 5PT (United Kingdom); Lord, S K [Joint Department of Physics, Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Downs Road, Sutton, Surrey SM2 5PT (United Kingdom); Ott, R J [Joint Department of Physics, Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Downs Road, Sutton, Surrey SM2 5PT (United Kingdom)

    2004-07-21

    In this paper two tests based on statistical models are presented and used to assess, quantify and provide positional information of the existence of bias and/or variations between planar images acquired at different times but under similar conditions. In the first test a linear regression model is fitted to the data in a pixelwise fashion, using three mathematical operators. In the second test a comparison using z-scoring is used based on the assumption that Poisson statistics are valid. For both tests the underlying assumptions are as simple and few as possible. The results are presented as parametric maps of either the three operators or the z-score. The z-score maps can then be thresholded to show the parts of the images which demonstrate change. Three different thresholding methods (naive, adaptive and multiple) are presented: together they cover almost all the needs for separating the signal from the background in the z-score maps. Where the expected size of the signal is known or can be estimated, a spatial correction technique (referred to as the reef correction) can be applied. These tests were applied to flood images used for the quality control of gamma camera uniformity. Simulated data were used to check the validity of the methods. Real data were acquired from four different cameras from two different institutions using a variety of acquisition parameters. The regression model found the bias in all five simulated cases and it also found patterns of unstable regions in real data where visual inspection of the flood images did not show any problems. In comparison the z-map revealed the differences in the simulated images from as low as 1.8 standard deviations from the mean, corresponding to a differential uniformity of 2.2% over the central field of view. In all cases studied, the reef correction increased significantly the sensitivity of the method and in most cases the specificity as well. The two proposed tests can be used either separately or in

  2. Statistical pixelwise inference models for planar data analysis: an application to gamma-camera uniformity monitoring

    International Nuclear Information System (INIS)

    Kalemis, A; Bailey, D L; Flower, M A; Lord, S K; Ott, R J

    2004-01-01

    In this paper two tests based on statistical models are presented and used to assess, quantify and provide positional information of the existence of bias and/or variations between planar images acquired at different times but under similar conditions. In the first test a linear regression model is fitted to the data in a pixelwise fashion, using three mathematical operators. In the second test a comparison using z-scoring is used based on the assumption that Poisson statistics are valid. For both tests the underlying assumptions are as simple and few as possible. The results are presented as parametric maps of either the three operators or the z-score. The z-score maps can then be thresholded to show the parts of the images which demonstrate change. Three different thresholding methods (naive, adaptive and multiple) are presented: together they cover almost all the needs for separating the signal from the background in the z-score maps. Where the expected size of the signal is known or can be estimated, a spatial correction technique (referred to as the reef correction) can be applied. These tests were applied to flood images used for the quality control of gamma camera uniformity. Simulated data were used to check the validity of the methods. Real data were acquired from four different cameras from two different institutions using a variety of acquisition parameters. The regression model found the bias in all five simulated cases and it also found patterns of unstable regions in real data where visual inspection of the flood images did not show any problems. In comparison the z-map revealed the differences in the simulated images from as low as 1.8 standard deviations from the mean, corresponding to a differential uniformity of 2.2% over the central field of view. In all cases studied, the reef correction increased significantly the sensitivity of the method and in most cases the specificity as well. The two proposed tests can be used either separately or in

  3. All-sky x-ray ampersand gamma-ray monitor (AXGAM)

    International Nuclear Information System (INIS)

    Tuemer, T.O.; O'Neill, T.J.; Hurley, K.

    1996-01-01

    A wide field-of-view, arcsecond imaging, high energy resolution x-ray and low energy gamma ray detector is proposed for a future space mission. It is specifically designed to detect and find counterparts at other wavelengths for Gamma Ray Bursts (GRBs). Detection of GRBs require wide field-of-view (π to 2 π field-of-view) and high sensitivity. This will be achieved by using high quantum efficiency CdZnTe pixel detectors, low energy threshold (few keV) to observe larger flux levels that may be possible at lower energies and large effective area (625 to 1,000 cd) per coded aperture imaging module. Counterpart searches can only be done with ultra high angular resolution (10 to 30 arcsecond FWHM) which gives 1 to 5 arcsecond position determination especially for strong GRBs. A few arcsecond resolution error box is expected to contain only one counterpart observed at another wavelength. This will be achieved by using ultra high spatial resolution pixel detectors (50 x 50 to 100 X 100 micron) and a similar resolution coded aperture to achieve the required angular resolution. AXGAM also has two other important advantages over similar detectors: (1) excellent low energy response (> 1 keV) and (2) high energy resolution (<6% at sign 5.9 keV, <3% at sign 14 keV, <4% at sign 122 keV). The low energy range may provide important new information on their cause and the high energy resolution is expected to help in the observation and identification of emission and absorption lines in the GRB spectrum. The effective energy range is planned to be 2 to 200 keV which is exceptionally wide for such a detector. AXGAM will be built in the form of a open-quotes Bucky Ballclose quotes using a coded aperture mask in a semi geodesic dome arrangement placed over a two-dimensional, high resolution CdZnTe pixel detector array using newly developed p-i-n detector technology. The p-i-n structure decreases the electron and hole trapping effect and increases energy resolution significantly

  4. FMC-based Neutron and Gamma Radiation Monitoring Module for xTCA Applications

    CERN Document Server

    Kozak, T; Napieralski, A

    2012-01-01

    The machines used in High Energy Physics (HEP) experiments, such as accelerators or tokamaks, are sources of gamma and neutron radiation fields. The radiation has a negative influence on electronics and can lead to the incorrect functioning of complex control and diagnostic system designed for HEP machines. Therefore, in most cases the electronic equipments is installed in radiation-safe areas, but in some cases this rule is omitted to decrease costs of the project. The European X-ray Free Electron Laser (E-XFEL), being under construction at DESY research center, is a good example. The E-XFEL uses single tunnel and part of the electronic system will be installed next to main beam pipe and exposed to radiation. The modern Advanced/Micro Telecommunications Computing Architecture (ATCA/μTCA) standards are foreseen as a base for control and diagnostic system for this new project. These flexible standards provide high reliability, availability and usability for the system which can be decreased by negative influe...

  5. Neutron activation analysis, gamma ray spectrometry and radiation environment monitoring instrument concept: GEORAD

    International Nuclear Information System (INIS)

    Ambrosi, R.M.; Talboys, D.L.; Sims, M.R.; Bannister, N.P.; Makarewicz, M.; Stevenson, T.; Hutchinson, I.B.; Watterson, J.I.W.; Lanza, R.C.; Richter, L.; Mills, A.; Fraser, G.W.

    2005-01-01

    Geological processes on Earth can be related to those that may have occurred in past epochs on Mars, if analytical methods used on Earth can be operated remotely on the surface of the Red Planet. Nuclear analytical techniques commonly used in terrestrial geology are neutron activation analysis (NAA) and gamma-ray spectroscopy (GRS), which determine the elemental composition, elemental concentration and stratigraphical distribution of water in rocks and soils. We describe a detector concept called GEORAD (GEOlogical and RADiation environment package) for the proposed ExoMars rover within the ESA's Aurora Programme for the exploration of the Solar System. GEORAD consists of a compact neutron source for the NAA of rocks and soils and a GRS. The GRS has a dual role since it can be used for natural radioactivity studies and NAA. A fully depleted silicon detector coupled to neutron sensitive converters measures the solar particle and neutron flux interacting with the Martian surface. We describe how the GEORAD detector suite could contribute to the geological and biological characterisation of Mars both for the detection of extinct or extant life and to evaluate potential hazards facing future manned missions. We show how GEORAD measurements complement the astrobiological objectives of the Aurora programme

  6. Sensitivity analysis of high resolution gamma-ray detection for safeguards monitoring at natural uranium conversion facilities

    Energy Technology Data Exchange (ETDEWEB)

    Dewji, S.A., E-mail: dewjisa@ornl.gov [Oak Ridge National Laboratory, PO Box 2008 MS-6335, Oak Ridge TN 37831 (United States); Georgia Institute of Technology, 770 State Street, Atlanta, GA 30332-0745 (United States); Croft, S. [Oak Ridge National Laboratory, PO Box 2008 MS-6335, Oak Ridge TN 37831 (United States); Hertel, N.E. [Oak Ridge National Laboratory, PO Box 2008 MS-6335, Oak Ridge TN 37831 (United States); Georgia Institute of Technology, 770 State Street, Atlanta, GA 30332-0745 (United States)

    2017-03-11

    Under the policies proposed by recent International Atomic Energy Agency (IAEA) circulars and policy papers, implementation of safeguards exists when any purified aqueous uranium solution or uranium oxides suitable for isotopic enrichment or fuel fabrication exists. Under IAEA Policy Paper 18, the starting point for nuclear material under safeguards was reinterpreted, suggesting that purified uranium compounds should be subject to safeguards procedures no later than the first point in the conversion process. In response to this technical need, a combination of simulation models and experimental measurements were employed in previous work to develop and validate gamma-ray nondestructive assay monitoring systems in a natural uranium conversion plant (NUCP). In particular, uranyl nitrate (UO{sub 2}(NO{sub 3}){sub 2}) solution exiting solvent extraction was identified as a key measurement point (KMP). Passive nondestructive assay techniques using high resolution gamma-ray spectroscopy were evaluated to determine their viability as a technical means for drawing safeguards conclusions at NUCPs, and if the IAEA detection requirements of 1 significant quantity (SQ) can be met in a timely manner. Building upon the aforementioned previous validation work on detector sensitivity to varying concentrations of uranyl nitrate via a series of dilution measurements, this work investigates detector response parameter sensitivities to gamma-ray signatures of uranyl nitrate. The full energy peak efficiency of a detection system is dependent upon the sample, geometry, absorption, and intrinsic efficiency parameters. Perturbation of these parameters translates into corresponding variations of the 185.7 keV peak area of the {sup 235}U in uranyl nitrate. Such perturbations in the assayed signature impact the quality or versatility of the safeguards conclusions drawn. Given the potentially high throughput of uranyl nitrate in NUCPs, the ability to assay 1 SQ of material requires

  7. Combining Internet monitoring processes, packaging and isotopic analyses to determine the market structure: example of Gamma Butyrolactone.

    Science.gov (United States)

    Pazos, Diego; Giannasi, Pauline; Rossy, Quentin; Esseiva, Pierre

    2013-07-10

    The Internet is becoming more and more popular among drug users. The use of websites and forums to obtain illicit drugs and relevant information about the means of consumption is a growing phenomenon mainly for new synthetic drugs. Gamma Butyrolactone (GBL), a chemical precursor of Gamma Hydroxy Butyric acid (GHB), is used as a "club drug" and also in drug facilitated sexual assaults. Its market takes place mainly on the Internet through online websites but the structure of the market remains unknown. This research aims to combine digital, physical and chemical information to help understand the distribution routes and the structure of the GBL market. Based on an Internet monitoring process, thirty-nine websites selling GBL, mainly in the Netherlands, were detected between January 2010 and December 2011. Seventeen websites were categorized into six groups based on digital traces (e.g. IP addresses and contact information). In parallel, twenty-five bulk GBL specimens were purchased from sixteen websites for packaging comparisons and carbon isotopic measurements. Packaging information showed a high correlation with digital data confirming the links previously established whereas chemical information revealed undetected links and provided complementary information. Indeed, while digital and packaging data give relevant information about the retailers, the supply routes and the distribution close to the consumer, the carbon isotopic data provides upstream information about the production level and in particular the synthesis pathways and the chemical precursors. A three-level structured market has been thereby identified with a production level mainly located in China and in Germany, an online distribution level mainly hosted in the Netherlands and the customers who order on the Internet. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  8. The New HARSHAW Extremity Dosimeters for Gamma and Beta Ray Monitoring

    International Nuclear Information System (INIS)

    Fellinger, J.; Majewski, M.; Rotunda, J.; Tawi, R.

    1997-01-01

    Large personnel dosimetry services providing extremity monitoring with finger rings based on thermoluminescent detectors have long been looking for a practical method for automated reading including automated identification of the detectors.All existing methods are at least not very suitable for medical applications, particularly for surgery, due to the fact that cold sterilization is usually impossible.Bicron radiation Measurement Products developed in co-operation with the Austrian Research Centre Seibersdorf a new finger ring dosimeter DXT-RAD as a fast and economic solution for fully automated evaluation of extremity dosemeters. (authors)

  9. Silicon PIN diode based electron-gamma coincidence detector system for Noble Gases monitoring.

    Science.gov (United States)

    Khrustalev, K; Popov, V Yu; Popov, Yu S

    2017-08-01

    We present a new second generation SiPIN based electron-photon coincidence detector system developed by Lares Ltd. for use in the Noble Gas measurement systems of the International Monitoring System and the On-site Inspection verification regimes of the Comprehensive Nuclear-Test Ban Treaty (CTBT). The SiPIN provide superior energy resolution for electrons. Our work describes the improvements made in the second generation detector cells and the potential use of such detector systems for other applications such as In-Situ Kr-85 measurements for non-proliferation purposes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Dosimetry in mixed (n,gamma) fields in relation to personnel monitoring

    International Nuclear Information System (INIS)

    Nikodemova, D.; Hrabovcova, A.; Kubu, M.

    1987-01-01

    Neutron spectra were determined using neutron detection with a set of moderating spheres and the SAND computer method. A 6 LiI crystal or a pair of 6 LiF- 7 LiF thermoluminescence detectors was placed in the centre of 7 moderating spheres of 5 to 30 cm in diameter. 252 Cf and 241 Am-Be source were used in the calibration of the multisphere spectrometer. Neutron scattering from the walls, floor and ceiling was taken into consideration. The contribution of scattered neutrons was also determined for the case of measuring the 241 Am-Be spectrum with the source placed behind a water wall 10 cm thick. It is shown how the neutron energy distribution and the values of dose quantities altered as a result of the presence of scattered neutrons. The result of the presence of scattered neutrons. The results are discussed with respect to personnel monitoring. (author)

  11. Monitoring of the infrastructure and services used to handle and automatically produce Alignment and Calibration conditions at CMS

    CERN Document Server

    Sipos, Roland; Franzoni, Giovanni; Di Guida, Salvatore; Pfeiffer, Andreas

    2017-01-01

    The Compact Muon Solenoid (CMS) experiment makes a vast use of alignment and calibration measurements in several crucial workflows in the event selection at the High Level Trigger (HLT), in the processing of the recorded collisions and in the production of simulated events.A suite of services addresses the key requirements for the handling of the alignment and calibration conditions such as recording the status of the experiment and of the ongoing data taking, accepting conditions data updates provided by the detector experts, aggregating and navigating the calibration scenarios, and distributing conditions for consumption by the collaborators. Since a large fraction of such services is critical for the data taking and event filtering in the HLT, a comprehensive monitoring and alarm generating system had to be developed. Such monitoring system has been developed based on the open source industry standard for monitoring and alerting services (Nagios) to monitor the database back-end, the hosting nodes and k...

  12. Monitoring of the infrastructure and services used to handle and automatically produce Alignment and Calibration conditions at CMS

    Science.gov (United States)

    Sipos, Roland; Govi, Giacomo; Franzoni, Giovanni; Di Guida, Salvatore; Pfeiffer, Andreas

    2017-10-01

    The CMS experiment at CERN LHC has a dedicated infrastructure to handle the alignment and calibration data. This infrastructure is composed of several services, which take on various data management tasks required for the consumption of the non-event data (also called as condition data) in the experiment activities. The criticality of these tasks imposes tights requirements for the availability and the reliability of the services executing them. In this scope, a comprehensive monitoring and alarm generating system has been developed. The system has been implemented based on the Nagios open source industry standard for monitoring and alerting services, and monitors the database back-end, the hosting nodes and key heart-beat functionalities for all the services involved. This paper describes the design, implementation and operational experience with the monitoring system developed and deployed at CMS in 2016.

  13. Organic liquid scintillation detectors for on-the-fly neutron/gamma alarming and radionuclide identification in a pedestrian radiation portal monitor

    Science.gov (United States)

    Paff, Marc Gerrit; Ruch, Marc L.; Poitrasson-Riviere, Alexis; Sagadevan, Athena; Clarke, Shaun D.; Pozzi, Sara

    2015-07-01

    We present new experimental results from a radiation portal monitor based on the use of organic liquid scintillators. The system was tested as part of a 3He-free radiation portal monitor testing campaign at the European Commission's Joint Research Centre in Ispra, Italy, in February 2014. The radiation portal monitor was subjected to a wide range of test conditions described in ANSI N42.35, including a variety of gamma-ray sources and a 20,000 n/s 252Cf source. A false alarm test tested whether radiation portal monitors ever alarmed in the presence of only natural background. The University of Michigan Detection for Nuclear Nonproliferation Group's system triggered zero false alarms in 2739 trials. It consistently alarmed on a variety of gamma-ray sources travelling at 1.2 m/s at a 70 cm source to detector distance. The neutron source was detected at speeds up to 3 m/s and in configurations with up to 8 cm of high density polyethylene shielding. The success of on-the-fly radionuclide identification varied with the gamma-ray source measured as well as with which of two radionuclide identification methods was used. Both methods used a least squares comparison between the measured pulse height distributions to library spectra to pick the best match. The methods varied in how the pulse height distributions were modified prior to the least squares comparison. Correct identification rates were as high as 100% for highly enriched uranium, but as low as 50% for 241Am. Both radionuclide identification algorithms produced mixed results, but the concept of using liquid scintillation detectors for gamma-ray and neutron alarming in radiation portal monitor was validated.

  14. Automatic Imitation

    Science.gov (United States)

    Heyes, Cecilia

    2011-01-01

    "Automatic imitation" is a type of stimulus-response compatibility effect in which the topographical features of task-irrelevant action stimuli facilitate similar, and interfere with dissimilar, responses. This article reviews behavioral, neurophysiological, and neuroimaging research on automatic imitation, asking in what sense it is "automatic"…

  15. Monitoring of gamma radiolytic degradation products of methoxychlor pesticide in water by solid phase micro-extraction using hplc and GC-MS (abstract)

    International Nuclear Information System (INIS)

    Butt, S.B.; Zafar, A.

    2011-01-01

    Monitoring, removal and management of toxic chemicals is an essential area of study regarding sustainable progress. Different approaches are adopted to eliminate these water born toxics from water and waste water. Among these gamma radiolytic is an emerging option. This ionization radiation generates highly reactive radicals that reacts with pollutants and hence eliminates these. A solid-phase micro-extraction (SPME) procedure has been developed for the successful preconcentration of organic pollutant irradiated water. A SPME fused-silica fiber coated with Polyacrylate was used as a probe to extract the organic pollutant after irradiation. In this reference, degradation of priority organic pollutant methoxychlor (1, 1, 1-Trichloro 2, 2-bis (p-methoxyphenyl) ethane, in water by gamma irradiation under varied experimental conditions has been investigated. The degree of gamma radiolytic degradation was monitored by HPLC-UV and GC-MS. For 4 kGy and 5 kGy gamma radiation dose at a rate of 200 kGyh/sup -1/ greater or equal to 95 % and 98 % MXC was degraded respectively. The degradation products were identified by Mass Spectrometry after comparing their MS spectras with the NIST 98 library. The major degradation occurs via dechlorination, dehydro chlorination, by the detachment of methoxyphenyl from MXC and by interaction of other radicals generated by the water radiolysis. (author)

  16. SU-E-I-10: Automatic Monitoring of Accumulated Dose Indices From DICOM RDSR to Improve Radiation Safety in X-Ray Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Omar, A; Bujila, R; Nowik, P; Karambatsakidou, A [Karolinska University Hospital, Stockholm (Sweden)

    2014-06-01

    Purpose: To investigate the potential benefits of automatic monitoring of accumulated patient and staff dose indicators, i.e., CAK and KAP, from DICOM Radiation Dose Structured Reports (RDSR) in x-ray angiography (XA). Methods: Recently RDSR has enabled the convenient aggregation of dose indices and technique parameters for XA procedures. The information contained in RDSR objects for three XA systems, dedicated to different types of clinical procedures, has been collected and aggregated in a database for over one year using a system developed with open-source software at the Karolinska University Hospital. Patient weight was complemented to the RDSR data via an interface with the Hospital Information System (HIS). Results: The linearly approximated trend in KAP over a time period of a year for cerebrovascular, pelvic/peripheral vascular, and cardiovascular procedures showed a decrease of 12%, 20%, and 14%, respectively. The decrease was mainly due to hardware/software upgrades and new low-dose imaging protocols, and partially due to ongoing systematic radiation safety education of the clinical staff. The CAK was in excess of 3 Gy for 15 procedures, and exceeded 5 Gy for 3 procedures. The dose indices have also shown a significant dependence on patient weight for cardiovascular and pelvic/peripheral vascular procedures; a 10 kg shift in mean patient weight can result in a dose index increase of 25%. Conclusion: Automatic monitoring of accumulated dose indices can be utilized to notify the clinical staff and medical physicists when the dose index has exceeded a predetermined action level. This allows for convenient and systematic follow-up of patients in risk of developing deterministic skin injuries. Furthermore, trend analyses of dose indices over time is a valuable resource for the identification of potential positive or negative effects (dose increase/decrease) from changes in hardware, software, and clinical work habits.

  17. SU-E-I-10: Automatic Monitoring of Accumulated Dose Indices From DICOM RDSR to Improve Radiation Safety in X-Ray Angiography

    International Nuclear Information System (INIS)

    Omar, A; Bujila, R; Nowik, P; Karambatsakidou, A

    2014-01-01

    Purpose: To investigate the potential benefits of automatic monitoring of accumulated patient and staff dose indicators, i.e., CAK and KAP, from DICOM Radiation Dose Structured Reports (RDSR) in x-ray angiography (XA). Methods: Recently RDSR has enabled the convenient aggregation of dose indices and technique parameters for XA procedures. The information contained in RDSR objects for three XA systems, dedicated to different types of clinical procedures, has been collected and aggregated in a database for over one year using a system developed with open-source software at the Karolinska University Hospital. Patient weight was complemented to the RDSR data via an interface with the Hospital Information System (HIS). Results: The linearly approximated trend in KAP over a time period of a year for cerebrovascular, pelvic/peripheral vascular, and cardiovascular procedures showed a decrease of 12%, 20%, and 14%, respectively. The decrease was mainly due to hardware/software upgrades and new low-dose imaging protocols, and partially due to ongoing systematic radiation safety education of the clinical staff. The CAK was in excess of 3 Gy for 15 procedures, and exceeded 5 Gy for 3 procedures. The dose indices have also shown a significant dependence on patient weight for cardiovascular and pelvic/peripheral vascular procedures; a 10 kg shift in mean patient weight can result in a dose index increase of 25%. Conclusion: Automatic monitoring of accumulated dose indices can be utilized to notify the clinical staff and medical physicists when the dose index has exceeded a predetermined action level. This allows for convenient and systematic follow-up of patients in risk of developing deterministic skin injuries. Furthermore, trend analyses of dose indices over time is a valuable resource for the identification of potential positive or negative effects (dose increase/decrease) from changes in hardware, software, and clinical work habits

  18. Application of pattern recognition technique on randon signals for automatic monitoring of dynamic systems with emphasis on nuclear reactors

    International Nuclear Information System (INIS)

    Nascimento, J.A. do.

    1981-01-01

    The time varying or noise component of dynamic system parameters contains information on the system state. Pattern recognition analysis of noise signals for such systems is a powerful technique for assessing 'system normality' or 'correct operation'. Data analysis with modern small computers enables the otherwise unmanageable volumes of data to be processed on line and the results presented in a meaningful form. These informations provide necessary data for maintaining the system at optimum operating conditions. An automatic pattern recognition program, PSDREC, developmed for the surveillance of nuclear reactor and rotating machinery is described, and the relevant theory is outlined. This program, which applies 8 statistical tests to calculated power spectral density (PSD) distributions, was earlier installed in a PDP-11/45 computer at IPEN. In this work it has been used to separately analyse recorded signals from three systems, namely an operational BWR power reactor (neutron signals), a water pump and a diesel motor (vibration signals). The latter two were, respectively, operated over a wide-range of flow and load conditions. The statistical tests were applied to frequency bands of (0,1-40) Hz, (0-1000) Hz and (0,20000) Hz. for the BWR, pump and diesel signal data, respectively. Operation and analysis conditions are given together with representative graphs of the analysed PSD distributions. Results of the tests - discussed in some detail - are considered to be satisfactory. (Author) [pt

  19. A Multi-Scale Flood Monitoring System Based on Fully Automatic MODIS and TerraSAR-X Processing Chains

    Directory of Open Access Journals (Sweden)

    Enrico Stein

    2013-10-01

    Full Text Available A two-component fully automated flood monitoring system is described and evaluated. This is a result of combining two individual flood services that are currently under development at DLR’s (German Aerospace Center Center for Satellite based Crisis Information (ZKI to rapidly support disaster management activities. A first-phase monitoring component of the system systematically detects potential flood events on a continental scale using daily-acquired medium spatial resolution optical data from the Moderate Resolution Imaging Spectroradiometer (MODIS. A threshold set controls the activation of the second-phase crisis component of the system, which derives flood information at higher spatial detail using a Synthetic Aperture Radar (SAR based satellite mission (TerraSAR-X. The proposed activation procedure finds use in the identification of flood situations in different spatial resolutions and in the time-critical and on demand programming of SAR satellite acquisitions at an early stage of an evolving flood situation. The automated processing chains of the MODIS (MFS and the TerraSAR-X Flood Service (TFS include data pre-processing, the computation and adaptation of global auxiliary data, thematic classification, and the subsequent dissemination of flood maps using an interactive web-client. The system is operationally demonstrated and evaluated via the monitoring two recent flood events in Russia 2013 and Albania/Montenegro 2013.

  20. Development and implementation of an automated system for antiquated of the process of gamma radiation monitors calibration; Desenvolvimento e implantacao de um sistema automatizado para adequacao do processo de calibracao de monitores de radiacao gama

    Energy Technology Data Exchange (ETDEWEB)

    Silva Junior, Iremar Alves

    2012-07-01

    In this study it was carried out the development and implementation of a system for the appropriate process of gamma radiation monitors calibration, constituted by a pneumatic dispositive to exchange the attenuators and a positioning table, both actuated through a control panel. We also implemented a System of Caesa-Gammatron Irradiator, which increased the range of the air kerma rates, due to its higher activity comparing with the current system of gamma radiation in use in the calibration laboratory of gamma irradiation. Hence, it was necessary the installation of an attenuator dispositive remotely controlled in this irradiator system. Lastly, it was carried out an evaluation of the reduction in the rates of the occupational dose. This dissertation was developed with the aim of improving the quality of the services of calibration and tests of gamma radiation monitors - provided by the IPEN Laboratory of Instrument Calibration - as well as decreasing the occupational dose of the technicians involved in the process of calibration, following thus the principles of radiation protection. (author)

  1. SGR J1550-5418 BURSTS DETECTED WITH THE FERMI GAMMA-RAY BURST MONITOR DURING ITS MOST PROLIFIC ACTIVITY

    Energy Technology Data Exchange (ETDEWEB)

    Van der Horst, A. J.; Finger, M. H. [Universities Space Research Association, NSSTC, Huntsville, AL 35805 (United States); Kouveliotou, C. [Space Science Office, VP62, NASA/Marshall Space Flight Center, Huntsville, AL 35812 (United States); Gorgone, N. M. [Connecticut College, New London, CT 06320 (United States); Kaneko, Y.; Goegues, E.; Lin, L. [Sabanc Latin-Small-Letter-Dotless-I University, Orhanl Latin-Small-Letter-Dotless-I -Tuzla, Istanbul 34956 (Turkey); Baring, M. G. [Department of Physics and Astronomy, Rice University, MS-108, P.O. Box 1892, Houston, TX 77251 (United States); Guiriec, S.; Bhat, P. N.; Chaplin, V. L.; Goldstein, A. [University of Alabama, Huntsville, CSPAR, Huntsville, AL 35805 (United States); Granot, J. [Racah Institute of Physics, Hebrew University, Jerusalem 91904 (Israel); Watts, A. L. [Astronomical Institute ' Anton Pannekoek' , University of Amsterdam, Postbus 94249, 1090 GE Amsterdam (Netherlands); Bissaldi, E.; Gruber, D. [Max Planck Institute for Extraterrestrial Physics, Giessenbachstrasse, Postfach 1312, 85748 Garching (Germany); Gehrels, N.; Harding, A. K. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Gibby, M. H.; Giles, M. M., E-mail: A.J.VanDerHorst@uva.nl [Jacobs Technology, Inc., Huntsville, AL (United States); and others

    2012-04-20

    We have performed detailed temporal and time-integrated spectral analysis of 286 bursts from SGR J1550-5418 detected with the Fermi Gamma-ray Burst Monitor (GBM) in 2009 January, resulting in the largest uniform sample of temporal and spectral properties of SGR J1550-5418 bursts. We have used the combination of broadband and high time-resolution data provided with GBM to perform statistical studies for the source properties. We determine the durations, emission times, duty cycles, and rise times for all bursts, and find that they are typical of SGR bursts. We explore various models in our spectral analysis, and conclude that the spectra of SGR J1550-5418 bursts in the 8-200 keV band are equally well described by optically thin thermal bremsstrahlung (OTTB), a power law (PL) with an exponential cutoff (Comptonized model), and two blackbody (BB) functions (BB+BB). In the spectral fits with the Comptonized model, we find a mean PL index of -0.92, close to the OTTB index of -1. We show that there is an anti-correlation between the Comptonized E{sub peak} and the burst fluence and average flux. For the BB+BB fits, we find that the fluences and emission areas of the two BB functions are correlated. The low-temperature BB has an emission area comparable to the neutron star surface area, independent of the temperature, while the high-temperature BB has a much smaller area and shows an anti-correlation between emission area and temperature. We compare the properties of these bursts with bursts observed from other SGR sources during extreme activations, and discuss the implications of our results in the context of magnetar burst models.

  2. SGR J1550-5418 Bursts Detected with the Fermi Gamma-Ray Burst Monitor during Its Most Prolific Activity

    Science.gov (United States)

    vanderHorst, A. J.; Kouveliotou, C.; Gorgone, N. M.; Kaneko, Y.; Baring, M. G.; Guiriec, S.; Gogus, E,; Granot, J.; Watts, A. L.; Lin, L.; hide

    2012-01-01

    We have performed detailed temporal and time-integrated spectral analysis of 286 bursts from SGR J1550-5418 detected with the Fermi Gamma-ray Burst Monitor (GBM) in 2009 January, resulting in the largest uniform sample of temporal and spectral properties of SGR J1550-5418 bursts. We have used the combination of broadband and high time-resolution data provided with GBM to perform statistical studies for the source properties.We determine the durations, emission times, duty cycles, and rise times for all bursts, and find that they are typical of SGR bursts. We explore various models in our spectral analysis, and conclude that the spectra of SGR J15505418 bursts in the 8-200 keV band are equally well described by optically thin thermal bremsstrahlung (OTTB), a power law (PL) with an exponential cutoff (Comptonized model), and two blackbody (BB) functions (BB+BB). In the spectral fits with the Comptonized model, we find a mean PL index of -0.92, close to the OTTB index of -1. We show that there is an anti-correlation between the Comptonized E(sub peak) and the burst fluence and average flux. For the BB+BBfits, we find that the fluences and emission areas of the two BB functions are correlated. The low-temperature BB has an emission area comparable to the neutron star surface area, independent of the temperature, while the high temperature BB has a much smaller area and shows an anti-correlation between emission area and temperature.We compare the properties of these bursts with bursts observed from other SGR sources during extreme activations, and discuss the implications of our results in the context of magnetar burst models.

  3. Gamma-gamma angular correlation measurement in the 100 Ru

    International Nuclear Information System (INIS)

    Kenchian, G.

    1990-01-01

    An angular correlation automatic spectrometer with two Ge(Li) detectors has been developed. The spectrometer moves automatically, controlled by a microcomputer. The gamma-gamma directional angular correlations of coincidence transitions have been measured in 100 Ru nuclide, following the β + and electron capture of 100 Rh. The 100 Rh source has been produced with 100 Ru(p,n) 100 Rh reaction, using the proton beam of the Cyclotron Accelerator insiding in 100 Ru isotope. (author)

  4. Reproducibility of the new automatic sample changer coupled to the gamma spectrometer as support for Neutronic Activation Analysis; Reprodutibilidade do novo trocador automático de amostras acoplado a espectrômetro gama como suporte à análise por ativação neutrônica

    Energy Technology Data Exchange (ETDEWEB)

    Venancio, Raoni J.M.; Menezes, Maria Ângela de B.C.; Dutra Neto, Aimoré, E-mail: raonirjv@hotmail.com, E-mail: raoni.venancio@cdtn.br, E-mail: menezes@cdtn.br, E-mail: dutraa@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Aiming to optimize and make the analyzes in gamma spectrometry more efficient, an automatic sample changer was recently developed for the gamma spectrometry step of the neutron activation analysis and was installed in the CDTN / CNEN Neutron Activation Laboratory. Usually, the exchange of samples in gamma spectrometry is performed manually, that is, it depends on an operator to perform the sample exchange. However, it is known that the manual exchange of the samples presents some setbacks, such as the low yield of the number of samples analyzed due to non-use in atypical schedules. The development of a system that exchanged samples regardless of date and time would solve these problems. Thus, an automatic sample exchange system has been developed that is connected to one of the laboratory's gamma spectrometers. The exchanger should replace the step that is performed manually. In order to evaluate whether the automatic exchanger will perform the swapping of samples correctly, preliminary tests were performed to verify the reproducibility of the system and consequently the stability of the results obtained. The tests already carried out were conducted under the normal operating conditions of the system, in order to present results that are closer to reality. The results showed that the system is working properly.

  5. Development and implementation of an automatic integration system for fibre optic sensors in the braiding process with the objective of online-monitoring of composite structures

    Science.gov (United States)

    Hufenbach, W.; Gude, M.; Czulak, A.; Kretschmann, Martin

    2014-04-01

    Increasing economic, political and ecological pressure leads to steadily rising percentage of modern processing and manufacturing processes for fibre reinforced polymers in industrial batch production. Component weights beneath a level achievable by classic construction materials, which lead to a reduced energy and cost balance during product lifetime, justify the higher fabrication costs. However, complex quality control and failure prediction slow down the substitution by composite materials. High-resolution fibre-optic sensors (FOS), due their low diameter, high measuring point density and simple handling, show a high applicability potential for an automated sensor-integration in manufacturing processes, and therefore the online monitoring of composite products manufactured in industrial scale. Integrated sensors can be used to monitor manufacturing processes, part tests as well as the component structure during product life cycle, which simplifies allows quality control during production and the optimization of single manufacturing processes.[1;2] Furthermore, detailed failure analyses lead to a enhanced understanding of failure processes appearing in composite materials. This leads to a lower wastrel number and products of a higher value and longer product life cycle, whereby costs, material and energy are saved. This work shows an automation approach for FOS-integration in the braiding process. For that purpose a braiding wheel has been supplemented with an appliance for automatic sensor application, which has been used to manufacture preforms of high-pressure composite vessels with FOS-networks integrated between the fibre layers. All following manufacturing processes (vacuum infiltration, curing) and component tests (quasi-static pressure test, programmed delamination) were monitored with the help of the integrated sensor networks. Keywords: SHM, high-pressure composite vessel, braiding, automated sensor integration, pressure test, quality control, optic

  6. Performance evaluation and operational experience with a semi-automatic monitor for the radiological characterization of low-level wastes

    International Nuclear Information System (INIS)

    Davey, E.C.; Csullog, G.W.

    1987-03-01

    Chalk River Nuclear Laboratories (CRNL) have undertaken a Waste Disposal Project to co-ordinate the transition from the current practice of interim storage to permanent disposal for low-level radioactive wastes (LLW). The strategy of the project is to classify and segregate waste segments according to their hazardous radioactive lifetimes and to emplace them in disposal facilities engineered to isolate and contain them. To support this strategy, a waste characterization program was set up to estimate the volume and radioisotope inventories of the wastes managed by CRNL. A key element of the program is the demonstration of a non-invasive measurement technique for the isotope-specific characterization of solid LLW. This paper describes the approach taken at CRNL for the non-invasive assay of LLW and the field performance and early operational experience with a waste characterization monitor to be used in a waste processing facility

  7. Performance evaluation and operational experience with a semi-automatic monitor for the radiological characterization of low-level wastes

    International Nuclear Information System (INIS)

    Davey, E.C.; Csullog, G.W.

    1987-01-01

    Chalk River Nuclear Laboratories (CRNL) have undertaken a Waste Disposal Project to co-ordinate the transition from the current practice of interim storage to permanent disposal for low-level radioactive wastes (LLW). The strategy of the project is to classify and segregate waste segments according to their hazardous radioactive lifetimes and to emplace them in disposal facilities engineered to isolate and contain them. To support this strategy, a waste characterization program was set up to estimate the volume and radioisotope inventories of the wastes managed by CRNL. A key element of the program is the demonstration of a non-invasive measurement technique for the isotope-specific characterization of solid LLW. This paper describes the approach taken at CRNL for the non-invasive assay of LLW and the field performance and early operational experience with a waste characterization monitor to be used in a waste processing facility

  8. Results of 1999 Spectral Gamma-Ray and Neutron Moisture Monitoring of Boreholes at Specific Retention Facilities in the 200 East Area, Hanford Site

    Energy Technology Data Exchange (ETDEWEB)

    DG Horton; RR Randall

    2000-01-18

    Twenty-eight wells and boreholes in the 200 East Are% Hanford Site, Washington were monitored in 1999. The monitored facilities were past-practice liquid waste disposal facilities and consisted of six cribs and nineteen ''specific retention'' cribs and trenches. Monitoring consisted of spectral gamma-ray and neutron moisture logging. All data are included in Appendix B. The isotopes {sup 137}Cs, {sup 60}Co, {sup 235}U, {sup 238}U, and {sup 154}Eu were identified on spectral gamma logs from boreholes monitoring the PUREX specific retention facilities; the isotopes {sup 137}Cs, {sup 60}Co, {sup 125}Sb, and {sup 154}Eu were identified on the logs from boreholes at the BC Controlled Area cribs and trenches; and {sup 137}Cs, {sup 60}Co, and {sup 125}Sb were, identified on the logs from boreholes at the BX specific retention trenches. Three boreholes in the BC Controlled Area and one at the BX trenches had previous spectral gamma logs available for comparison with 1999 logs. Two of those logs showed that changes in the subsurface distribution of {sup 137}CS and/or {sup 60}Co had occurred since 1992. Although the changes are not great, they do point to continued movement of contaminants in the vadose zone. The logs obtained in 1999 create a larger baseline for comparison with future logs. Numerous historical gross gamma logs exist from most of the boreholes logged. Qualitative comparison of those logs with the 1999 logs show many substantial changes, most of which reflect the decay of deeper short-lived isotopes, such as {sup 106}Ru and {sup 125}Sb, and the much slower decay of shallower and longer-lived isotopes such as {sup 137}Cs. The radionuclides {sup 137}Cs and {sup 60}Co have moved in two boreholes since 1992. Given the amount of movement and the half-lives of the isotopes, it is expected that they will decay to insignificant amounts before reaching groundwater. However, gamma ray logging cannot detect many of the contaminants of interest such

  9. Automatic sweep circuit

    International Nuclear Information System (INIS)

    Keefe, D.J.

    1980-01-01

    An automatically sweeping circuit for searching for an evoked response in an output signal in time with respect to a trigger input is described. Digital counters are used to activate a detector at precise intervals, and monitoring is repeated for statistical accuracy. If the response is not found then a different time window is examined until the signal is found

  10. Automatic sweep circuit

    Science.gov (United States)

    Keefe, Donald J.

    1980-01-01

    An automatically sweeping circuit for searching for an evoked response in an output signal in time with respect to a trigger input. Digital counters are used to activate a detector at precise intervals, and monitoring is repeated for statistical accuracy. If the response is not found then a different time window is examined until the signal is found.

  11. Gamma teletopography

    International Nuclear Information System (INIS)

    Simonet, G.

    1987-06-01

    The mapping of gamma sources radiation emission in a nuclear plant is an important safety point. A remote gamma ray mapping process was developed in SPS/CEA/SACLAY. It uses the ''pinhole camera'' principle, precursor of photography. It mainly consists of a radiation proof box, with a small orifice, containing sensitive emulsions at the opposite. A first conventional photographic type emulsion photographs the area. A second photographic emulsion shows up the gamma radiations. The superim position of the two shots gives immediate informations of the precise location of each source of radiation in the observed area. To make easier the presentation and to improve the accuracy of the results for radiation levels mapping, the obtained films are digitally processed. The processing assigns a colours scale to the various levels of observed radiations. Taking account physical data and standard parameters, it gets possible to estimate the dose rate. The device is portable. Its compactness and fully independent nature make it suitable for use anywhere. It can be adapted to a remote automatic handling system, robot... so as to avoid all operator exposure when the local dose rate is too high [fr

  12. Development and Implementation of an Automatic Continuous Online Monitoring and Control Platform for Polymerization Reactions to Sharply Boost Energy and Resource Efficiency in Polymer Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Reed, Wayne [Tulane Univ., New Orleans, LA (United States); Drenski, Michael [Tulane Univ., New Orleans, LA (United States); Romagnoli, Jose [Tulane Univ., New Orleans, LA (United States)

    2017-10-16

    The project goal was to create an energy saving paradigm shift in how polymers are manufactured in the 21st century. It used Automatic Continuous Online Monitoring of Polymerization reactions (ACOMP) integrated for the first time with automatic active control to create the innovative ‘ACOMP/Control Interface’, or ‘ACOMP/CI’. ACOMP/CI will begin the transformation from old, inefficient processes into highly evolved, energy and resource efficient ones. The ACOMP platform is broadly applicable to many types of reactions and processes throughout the vast polymer industry. The industry provides materials for sectors such as automotive, aerospace, oil recovery, agriculture, paints, resins, adhesives, pharmaceuticals and therapeutic proteins, optics, electronics, lightweight building materials, and many more. The U.S. chemical industry is one of the last major sectors in which the U.S. has top global stature. It consumes 24% of all U.S. manufacturing energy, produces over $800B of product annually, supports 25% of the U.S. GDP and employs over 6 million people. It is also a major source of GHG emissions. Polymers make up approximately 30% of this sector. It is estimated that annually 60 TBtu of energy could be saved and 3 million tons less of GHG emissions produced by optimizing production in the polyolefin manufacturing sector alone. The project scope included first time design and prototyping of an ACOMP/CI, creation of active reaction controllers, and demonstration of control capabilities on ideal, low concentration polymerization reactions. All these elements of the scope were met, including advances and findings not originally anticipated. Extensions to more complex reactions, beyond the reactor capabilities of the current project ACOMP/CI, such as polyolefins and other high pressure/high temperature reactions, are being proposed in Fall 2017 to CESMII, a DoE based NNMI. The initial proposal was for a three year funded project, but this was reduced to a two

  13. Implementation of the Gamma Monitor Calibration Laboratory (LABCAL) of the Institute of Chemical, Biological, Radiological and Nuclear Defense (IDQBRN) of the Technology Center of the Brazilian Army (CTEx)

    Energy Technology Data Exchange (ETDEWEB)

    Balthar, Mario Cesar V.; Amorim, Aneuri de; Santos, Avelino dos and others, E-mail: mariobalthar@gmail.com [Centro Tecnológico do Exército (IDQBRN/CTEx), Rio de Janeiro, RJ (Brazil). Instituto de Defesa Química, Biológica, Radiológica e Nuclear

    2017-07-01

    The objective of this work is to describe the implementation and adaptation stages of the Gamma Monitor Calibration Laboratory (Laboratório de Calibração de Monitores Gama - LABCAL) of the Institute of Chemical, Biological, Radiological and Nuclear Defense (Instituto de Defesa Química, Biológica, Radiológica e Nuclear - IDQBRN) of the Technology Center of the Brazilian Army (Centro Tecnológico do Exército - CTEx). Calibration of the radiation monitors used by the Brazilian Army will be performed by quantitatively measuring the ambient dose equivalent, in compliance with national legislation. LABCAL still seeks licensing from CNEN and INMETRO. The laboratory in intended to supply the total demand for calibration of ionizing radiation devices from the Brazilian Army. (author)

  14. Results of 1998 spectral gamma-ray monitoring of boreholes at the 216-Z-1A tile field, 216-Z-9 trench, and 216-Z-12 crib

    International Nuclear Information System (INIS)

    Horton, D.G.; Randall, R.R.

    1998-09-01

    This document describes the results of fiscal year 1998 vadose zone monitoring of three inactive liquid waste disposal facilities associated with the Plutonium Finishing Plant: the 216-Z-1A tile field, the 216-Z-9 trench, and the 216-Z-12 crib. Monitoring consisted of spectral gamma-ray logging of 21 boreholes. This work was performed by Pacific Northwest National Laboratory in conjunction with Three Rivers Scientific and Waste management Federal Services, inc. Northwest Operations. These three liquid waste disposal facilities were chosen for monitoring because they were identified as containing some of the most significant sources of radioactive contamination in the Hanford Site vadose zone. The basic question addressed by this logging activity is ''Has the configuration of subsurface contamination changed since it was last measured?'' Previous borehole logging and laboratory analyses provide the baseline data to help answer this question

  15. Implementation of the Gamma Monitor Calibration Laboratory (LABCAL) of the Institute of Chemical, Biological, Radiological and Nuclear Defense (IDQBRN) of the Technology Center of the Brazilian Army (CTEx)

    International Nuclear Information System (INIS)

    Balthar, Mario Cesar V.; Amorim, Aneuri de; Santos, Avelino dos and others

    2017-01-01

    The objective of this work is to describe the implementation and adaptation stages of the Gamma Monitor Calibration Laboratory (Laboratório de Calibração de Monitores Gama - LABCAL) of the Institute of Chemical, Biological, Radiological and Nuclear Defense (Instituto de Defesa Química, Biológica, Radiológica e Nuclear - IDQBRN) of the Technology Center of the Brazilian Army (Centro Tecnológico do Exército - CTEx). Calibration of the radiation monitors used by the Brazilian Army will be performed by quantitatively measuring the ambient dose equivalent, in compliance with national legislation. LABCAL still seeks licensing from CNEN and INMETRO. The laboratory in intended to supply the total demand for calibration of ionizing radiation devices from the Brazilian Army. (author)

  16. Automatic identification approach for high-performance liquid chromatography-multiple reaction monitoring fatty acid global profiling.

    Science.gov (United States)

    Tie, Cai; Hu, Ting; Jia, Zhi-Xin; Zhang, Jin-Lan

    2015-08-18

    Fatty acids (FAs) are a group of lipid molecules that are essential to organisms. As potential biomarkers for different diseases, FAs have attracted increasing attention from both biological researchers and the pharmaceutical industry. A sensitive and accurate method for globally profiling and identifying FAs is required for biomarker discovery. The high selectivity and sensitivity of high-performance liquid chromatography-multiple reaction monitoring (HPLC-MRM) gives it great potential to fulfill the need to identify FAs from complicated matrices. This paper developed a new approach for global FA profiling and identification for HPLC-MRM FA data mining. Mathematical models for identifying FAs were simulated using the isotope-induced retention time (RT) shift (IRS) and peak area ratios between parallel isotope peaks for a series of FA standards. The FA structures were predicated using another model based on the RT and molecular weight. Fully automated FA identification software was coded using the Qt platform based on these mathematical models. Different samples were used to verify the software. A high identification efficiency (greater than 75%) was observed when 96 FA species were identified in plasma. This FAs identification strategy promises to accelerate FA research and applications.

  17. An Automatic Monitoring System for High-Frequency Measuring and Real-Time Management of Cyanobacterial Blooms in Urban Water Bodies

    Directory of Open Access Journals (Sweden)

    Viet Tran Khac

    2018-01-01

    Full Text Available Urban lakes mitigate the negative impacts on the hydrological cycle and improve the quality of life in cities. Worldwide, the concern increases for the protection and management of urban water bodies. Since the physical-chemical and biological conditions of a small aquatic ecosystem can vary rapidly over time, traditional low frequency measurement approaches (weekly or monthly sampling limits the knowledge and the transfer of research outcomes to management decision-making. In this context, this paper presents an automatic monitoring system including a full-scale experimental site and a data transfer platform for high-frequency observations (every 5 min in a small and shallow urban lake (Lake Champs-sur-Marne, Paris, France, 10.3 ha. Lake stratification and mixing periods can be clearly observed, these periods are compared with the dynamic patterns of chlorophyll-a, phycocyanin, dissolved oxygen and pH. The results indicate that the phytoplankton growth corresponds with dissolved oxygen cycles. However, thermal stratification cannot totally explain the entire dynamic patterns of different physical-chemical and ecological variables. Besides, the cyanobacteria is one of the dominating groups of phytoplankton blooms during the lake stratification periods (8 August–29 September 2016. During the cooling mixed period (29 September–19 October 2016, the high concentration of chlorophyll-a is mainly caused by the other phytoplankton species, such as diatoms. Perspectives are discussed in order to apply this observation system for real-time management of water bodies and lakes.

  18. Validation of the Pangao PG-800A36 automatic wrist blood pressure monitor according to the European Society of Hypertension and the British Hypertension Society protocols.

    Science.gov (United States)

    Zhao, Hairong; Qiao, Weichang; Zhang, Rui; Cui, Peng; Hou, Fanglin; Zhang, Wenli

    2018-02-01

    The aim of this study was to validate the PG-800A36 automatic wrist blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010 and the British Hypertension Society (BHS) protocols. A total of 33 participants were initially included on the basis of the ESH-IP, followed by examination of 85 participants according to the BHS protocol. The procedures and analysis methods of the protocols were followed precisely with left arm/wrist sequential measurements by two trained observers using a mercury sphygmomanometer and one supervisor using the device. The device passed the ESH-IP with an average difference of 1.45±6.46 mmHg for systolic blood pressure and 1.25±5.10 mmHg for diastolic blood pressure. Furthermore, the A/A grade of the BHS protocol was achieved with an average difference of 1.84±6.94 mmHg for systolic blood pressure and 1.15±6.49 mmHg for diastolic blood pressure, and thus, the device also fulfilled the requirements of the Association for the Advancement of Medical Instrumentation. The Pangao PG-800A36 passed the requirements of the ESH-IP revision 2010 and achieved the A/A grade of the BHS protocol, which can be recommended for self-measurement in the general population.

  19. Daily monitoring of TeV gamma-ray emission from Mrk 421, Mrk 501, and the Crab Nebula with HAWC

    OpenAIRE

    Abeysekara, A. U.; Albert, A.; Alfaro, R.; Alvarez, C.; Álvarez, J. D.; Arceo, R.; Arteaga-Velázquez, J. C.; Rojas, D. Avila; Solares, H. A. Ayala; Barber, A. S.; Bautista-Elivar, N.; Gonzalez, J. Becerra; Becerril, A.; Belmont-Moreno, E.; BenZvi, S. Y.

    2017-01-01

    We present results from daily monitoring of gamma rays in the energy range $\\sim0.5$ to $\\sim100$ TeV with the first 17 months of data from the High Altitude Water Cherenkov (HAWC) Observatory. Its wide field of view of 2 steradians and duty cycle of $>95$% are unique features compared to other TeV observatories that allow us to observe every source that transits over HAWC for up to $\\sim6$ hours each sidereal day. This regular sampling yields unprecedented light curves from unbiased measurem...

  20. Comparison of neutron and gamma irradiation effects on KU1 fused silica monitored by electron paramagnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Bravo, D. [Department Fisica de Materiales, Universidad Autonoma de Madrid, E-28049 Madrid (Spain)], E-mail: david.bravo@uam.es; Lagomacini, J.C. [Department Fisica de Materiales, Universidad Autonoma de Madrid, E-28049 Madrid (Spain); Leon, M.; Martin, P. [Materiales para Fusion, CIEMAT, Avda. Complutense 22, E-28040 Madrid (Spain); Martin, A. [Department Fisica e Instalaciones, ETS Arquitectura UPM, E-28040 Madrid (Spain); Lopez, F.J. [Department Fisica de Materiales, Universidad Autonoma de Madrid, E-28049 Madrid (Spain); Ibarra, A. [Materiales para Fusion, CIEMAT, Avda. Complutense 22, E-28040 Madrid (Spain)

    2009-06-15

    Electron paramagnetic resonance (EPR) studies have been carried out on KU1 fused silica irradiated with neutrons at fluences 10{sup 21} and 10{sup 22} n/m{sup 2}, and gamma-ray doses up to 12 MGy. The effects of post-irradiation thermal annealing treatments, up to 850 deg. C, have also been investigated. Paramagnetic oxygen-related defects (POR and NBOHC) and E'-type defects have been identified and their concentration has been measured as a function of neutron fluence, gamma dose and post-irradiation annealing temperature. It is found that neutrons at the highest fluence generate a much higher concentration of defects (mainly E' and POR, both at concentrations about 5 x 10{sup 18} spins/cm{sup 3}) than gamma irradiations at the highest dose (mainly E' at a concentration about 4 x 10{sup 17} spins/cm{sup 3}). Moreover, for gamma-irradiated samples a lower treatment temperature (about 400 deg. C) is required to annihilate most of the observed defects than for neutron-irradiated ones (about 600 deg. C)

  1. Detoxification with titration and tapering in gamma-hydroxybutyrate (GHB) dependent patients : The Dutch GHB monitor project

    NARCIS (Netherlands)

    Dijkstra, Boukje A G; Kamal, Rama; van Noorden, Martijn S; de Haan, Hein; Loonen, Anton J.M.; De Jong, Cor A J

    2016-01-01

    BACKGROUND AND AIMS: Gamma-hydroxybutyrate (GHB) detoxification procedures have been insufficiently studied for effectiveness and safety. Based on case reports, benzodiazepines are generally regarded as first-choice agents in GHB detoxification. Detoxification by titration and tapering (DeTiTap)

  2. Treatment of trochanteric fractures with the gamma3 nail - methodology and early results of a prospective consecutive monitored clinical case series.

    Science.gov (United States)

    A C, Unger; E, Wilde; B, Kienast; C, Jürgens; A P, Schulz

    2014-01-01

    There is only sparse data on clinical results and complications of the third-generation Gamma nailing system (Gamma3, Stryker). Therefore, we started a large multi-centre case series in 2008. The aim of this paper is to present the study design and early results of a single arm of a prospective, consecutive, monitored, post-market follow-up evaluation of Gamma3 nails. From September 2009 to January 2012, 154 consecutive patients with an average age of 80 ± 1.43 years (50-99 years) and a trochanteric femoral fracture were included in the local arm of the trial. All patients that fulfilled the inclusion criteria were treated with a Gamma3 nail. Preoperative variables included age, gender, fracture classification, walking ability (Merle d'Aubigné score), daily activity level (retrospective Zuckerman score), ASA rating of operative risk, waiting time for operation, use of walker or crutches and body mass index (BMI). Skin-to-skin time, fluoroscopy time, blood loss, intraoperative complications and device information were recorded for each patient. Follow-up postoperative assessment was undertaken at 4, 12 and 24 months. Hip range of motion, pain around the hip and the tight, walking ability (Merle d'Aubigné score, Sahlgrenska mobility score) and management of daily life (Zuckerman score) were used to evaluate the outcome. The descriptive data of age, gender, BMI, ASA classification, fracture type and skin-to-skin time is similar to other studies. Median fluoroscopy time was 62 seconds (range: 4-225 seconds) and significantly shorter in closed reductions. No intraoperative implant-related complication was recorded. A cut-out of the leg-screw during assessment period occurred in 2.6% patients (n = 4). At the 12-month assessment two (1.8%) non-unions were identified and two patients (1.8%) had broken the femoral shaft below the 180 mm nail after a fall. Analysis of the scores showed significantly declined mobility and activity in daily life four months after operation

  3. Monitoring of the internal contamination of occupationally exposure personnel in services of nuclear medicine through the use of gamma cameras; Monitoreo de la contaminacion interna de personal ocupacionalmente expuesto en servicios de medicina nuclear mediante el uso de gamma camaras

    Energy Technology Data Exchange (ETDEWEB)

    Teran, M.; Paolino, A.; Savio, E. [Catedra de Radioquimica, Facultad de Quimica, Montevideo (Uruguay); Hermida, J.C. [Centro de Medicina Nuclear, Hospital de Clinicas, Facultad de Medicina, Montevideo (Uruguay); Dantas, B.M. [Laboratorio de Medidas In vivo, Instituto da Radioprotecao e Dosimetria, Rio de Janeiro (Brazil)

    2006-07-01

    The radionuclides incorporation can happen as a result of diverse activities; these include the work associated with the different stadiums of the nuclear fuel cycle, the use of radioactive sources in medicine, the scientific research, the agriculture and the industry. In Uruguay the main activities linked to the manipulation of open sources correspond those of Nuclear Medicine and from 2004, in the mark of the Project Arcal RLA 049 and being based on the Safety Guides of the IAEA it is implementing a program of internal monitoring in combined form the Nuclear Medicine Center of the Hospital of and the Radiochemistry class of the Faculty of Chemistry. In accordance with the publication of the ICRP 75 the emphasis of any monitoring program should be in the formal study of the doses in the workers to who are considered commendable of to receive in routine form an outstanding fraction of the dose limits or who work in areas where the exposures can be significant in the accident event. From April 2004, to the date has started a pilot plan by means of in that were established appropriate conditions of procedures and of safety in a reduced group of workers of the Nuclear Medicine area. In that period the first work limits, equipment adjustment, calibrations and registration systems were determined. The monitoring system implemented until the moment is carried out with a thyroid caption equipment. However these measurements are carried out in the university hospital embracing 40% of the involved workers of our country, with the purpose of reaching the covering of the biggest quantity of occupationally exposed personnel of private clinics. Also it was developed a new work proposal that allows to have an alternative measure method, in the event of not having the equipment habitually used. Among the conclusions of this work are that for the before exposed are considered the measure conditions but appropriate the following ones: Gamma Camera without collimator; Measurement

  4. External gamma radiation monitoring in the environs of Kaiga Generating Station (KGS), using thermoluminescent dosimeters, during the period 1989-2003

    International Nuclear Information System (INIS)

    Basu, A.S.; Chougaonkar, M.P.; Mayya, Y.S.; Puranik, V.D.; Reji, T.K.; Ravi, P.M.; Hegde, A.G.

    2005-05-01

    This publication reports the results of external gamma radiation monitoring using Thermoluminescent Dosimeters (TLDs), in the environs of Kaiga Generating Station (KGS) during its preoperational survey between October 1989 and June 1998. The report also presents quarterly and annual values of air dose during the operational phase of the station between July 1998 and Dec. 2003 around the environmcnt of KGS. The results of TLD analysis, during the period October 1989-June 1998, indicate that the average annual air dose for the locations monitored, was 502± 91 μGy/a. The general background of the environs around Kaiga during the operational period, i.e. July 1998 and Dec. 2003, between 2.3 km. to 32km. has been found to be 509±74 μGy/a. The report discusses the methodology and different analyses carried out. (author)

  5. Laboratory Automatic Titration of Chromium Plating and Electropolishing Solutions

    National Research Council Canada - National Science Library

    Sopok, Samuel

    2001-01-01

    .... The analytical chemistry literature lacks an adequate automatic titration method for the monitoring of chromic acid in chromium plating solutions and the monitoring of phosphoric and sulfuric acids...

  6. Radiation monitoring. Quarterly report for the Greater Manchester Fire and Civil Defence Authority and the Manchester Area Pollution Advisory Council. Manchester Area Gamma Radiation Air Monitoring System (MANAGRAMS), report covering period of 3 months 1 January to 31 March 1996

    International Nuclear Information System (INIS)

    1996-01-01

    Gamma radiation monitoring data from nine outstations in the Manchester area for the period 01/01/96 to 31/03/96 are presented. For each station there is a summary table, a background radiation graph showing 6 hour mean levels and a windrose graph showing the direction of the wind as a percentage of the total. A line graph comparison between stations is provided for the background 6 hour mean levels and a bar chart comparison of total dose. Graphs of temperature and barometric pressure taken from extra sensors at the Trafford station are presented. (UK)

  7. Monitoring the Therapeutic and Protective Role of the Anti oxidative Nutritional Factor β Carotene in gamma-Irradiated Rats

    International Nuclear Information System (INIS)

    Tawfik, S.S.; Mansour, H.H.

    2008-01-01

    Carotenoids are those substances, synthesized, only in plants that serve to protect the plants from free radicals. β-carotene, one of the carotenoids, has been thought to be of value to humans and other species, not only as precursors to vitamin A, but also for having excellent antioxidant properties. Four groups of rats were used to gain insight into the protective action of carotenes: control, β-carotene treated (30 mg/ kg body wt for 10 days), irradiated (4 fractions, each of 1.5 Gy gamma-rays during 10 days) and protracted group: rats received the same fractionated gamma-rays at the same time gavaged with β-carotene along the 10 days. Irradiated rats revealed significant decreases in p-carotene and glutathione (GSH) concentrations and significant increases in the activities of blood alkaline phosphatase (ALP), acid phosphatase (ACP), alanine transaminase (ALT), gamma-glutamyl transferase (GGT), catalase and contents of blood thiobarbituric acid-reactive substances (TBARS). In liver , tissue, TBARS content and catalase activity were raised while GSH was declined. The oral intake of β-carotene to irradiated rats was found to maintain the parameters measured near the control mean levels; i.e., increased content of blood β-carotene and GSH and modulated activities of ALP, ACP, ALT, GGT, catalase and TBARS level. It also, modulated the alterations of liver TBARS, catalase and GSH. Conclusion: β-carotene therapy significantly modulates oxidative damage induced by ionising radiation in rats

  8. A New Approach for the Determination of Dose Rate and Radioactivity for Detected Gamma Nuclides Using an Environmental Radiation Monitor Based on an NaI(Tl) Detector.

    Science.gov (United States)

    Ji, Young-Yong; Kim, Chang-Jong; Lim, Kyo-Sun; Lee, Wanno; Chang, Hyon-Sock; Chung, Kun Ho

    2017-10-01

    To expand the application of dose rate spectroscopy to the environment, the method using an environmental radiation monitor (ERM) based on a 3' × 3' NaI(Tl) detector was used to perform real-time monitoring of the dose rate and radioactivity for detected gamma nuclides in the ground around an ERM. Full-energy absorption peaks in the energy spectrum for dose rate were first identified to calculate the individual dose rates of Bi, Ac, Tl, and K distributed in the ground through interference correction because of the finite energy resolution of the NaI(Tl) detector used in an ERM. The radioactivity of the four natural radionuclides was then calculated from the in situ calibration factor-that is, the dose rate per unit curie-of the used ERM for the geometry of the ground in infinite half-space, which was theoretically estimated by Monte Carlo simulation. By an intercomparison using a portable HPGe and samples taken from the ground around an ERM, this method to calculate the dose rate and radioactivity of four nuclides using an ERM was experimentally verified and finally applied to remotely monitor them in real-time in the area in which the ERM had been installed.

  9. Long term monitoring of Gamma-Ray emission from the BL Lacertae object (1ES 2200+420)

    Science.gov (United States)

    Gunawardhana, Isuru; VERITAS Collaboration

    2016-03-01

    Blazars are a class of Active Galactic Nuclei (AGN) that have relativistic jets pointing along the observer line of sight. Blazars exhibit variable emission extending from radio to TeV energies. The variability timescale of the TeV flux is a key component of understanding the location of the very high energy emission zones. Deep observations of the quiescent state measurements are also required to disentangle the flaring state emission from quiescent state emission, a prerequisite for understanding the origin of blazar spectral variability. BL Lacertae (also known as 1ES 2200+420), as the namesake for all BL Lac objects, is a prime example of one such blazar. The VERITAS Observatory, an Imaging Atmospheric Cherenkov Telescope (IACT) array sensitive to gamma rays in the range from 85 GeV to 30 TeV, dedicates approximately 110 hours per year on deep observations of known gamma-ray blazars. In this talk, I will describe the TeV photon flux variability of BL Lacertae measured by VERITAS from 2013 to 2015.

  10. Automatic classification of gammas-gamma coincidence matrices

    International Nuclear Information System (INIS)

    Los Arcos Merino, J. M.; Gonzalez, J. A.

    1978-01-01

    The information obtained during a coincidence experiment, recorded on magnetic tape by a MULTI-8 minicomputer, is transferred to a new tape in 36 bit words, using the program LEC0M8. The classification in two dimensional matrix form is carried out off-line, on a magnetic disk file, by the program CLAFI. On finishing classification one obtains a copy of the coincidence matrix on the second magnetic tape. Both programs are written to be processed in that order with the UNIVAC 1106 computer of J.E.N. (Author) 4 refs

  11. Automatic classification of gamma-gamma coincidence matrices

    International Nuclear Information System (INIS)

    Los Arcos Merino, J.M.; Gonzalez Gonzalez, J.A.

    1978-01-01

    The information obtained during a coincidence experiment, recorded on magnetic tape by a Multi-8 minicomputer, is transferred to a new tape in 36 bit words, using the program Lecom8. The classification in two dimensional matrix form is carried out off-line, on a magnetic disk file, by the program Clafi. On finishing classification one obtains a copy of the coincidence matrix on the second magnetic tape. Both programs are written to be processed in that order with the Univac 1106 computer of J.E.N. (author)

  12. Radiation damage of light guide fibers in gamma radiation field - on-line monitoring of absorption centers formation

    International Nuclear Information System (INIS)

    Blaha, J.; Simane, C.; Finger, M.; Slunecka, M.; Finger, M. Jr.; Sluneckova, V.; Janata, A.; Vognar, M.; Sulc, M.

    2004-01-01

    The kinetics of radiation-induced changes of absorption coefficient was studied by online transmission spectra measurement for two different Kuraray light guide fibers. The samples were irradiated by bremsstrahlung gamma radiation, dose rates were from 2 Gy/s to 25 Gy/s. The kinetic coefficients both for absorption centers formation and for recovery processes were calculated. Good agreement of experimental data and simple one-short-lived absorption center model were received for radiation-hard light guide Kuraray (KFC). The more complicated process was observed on Kuraray (PSM) clear fiber. It was caused by the reaction of the oxygen dissolved in fiber and created radicals. The results are very useful for prediction of an optical fibers response in conditions of new nuclear and particle physics experiments. (author)

  13. Calibration of personnel monitors by exposure to gamma radiation with energies up to 9 MeV

    International Nuclear Information System (INIS)

    Leao, J.L.B.; Cunha, P.G. da; Diz, R.; Oberhofer, M.

    Occupational exposure with photons of high energy (higher than those from 60 Co) might occur from nuclear reactors and accelerators. Radiation monitors for absorbed dose determination, however, often do not have a wall thickness sufficient to establish electronical equilibrium in that energy range. Using calibration factors determined for lower energies (calibration factors for 60 Co radiation) might cause a significant underestimation of the soft tissue absorbed dose. The calibration factor of the personnel monitors of the Eberline Instrument Co.based on TL dosimeters of LiF is reported. This monitor was calibrated with 9 MeV photons produced by thermal neutrons capture in a Nitarget, at an absorbed dose rate of 125 rads/h at the C.E.N. in France. The results are compared with the corresponding calibration factors for different energies up to 60 Co radiation determined in the IRD (Instituto de Radioprotecao e Dosimetria Rio de Janeiro). (Author) [pt

  14. Dynamic gamma knife radiosurgery

    International Nuclear Information System (INIS)

    Luan Shuang; Swanson, Nathan; Chen Zhe; Ma Lijun

    2009-01-01

    Gamma knife has been the treatment of choice for various brain tumors and functional disorders. Current gamma knife radiosurgery is planned in a 'ball-packing' approach and delivered in a 'step-and-shoot' manner, i.e. it aims to 'pack' the different sized spherical high-dose volumes (called 'shots') into a tumor volume. We have developed a dynamic scheme for gamma knife radiosurgery based on the concept of 'dose-painting' to take advantage of the new robotic patient positioning system on the latest Gamma Knife C(TM) and Perfexion(TM) units. In our scheme, the spherical high dose volume created by the gamma knife unit will be viewed as a 3D spherical 'paintbrush', and treatment planning reduces to finding the best route of this 'paintbrush' to 'paint' a 3D tumor volume. Under our dose-painting concept, gamma knife radiosurgery becomes dynamic, where the patient moves continuously under the robotic positioning system. We have implemented a fully automatic dynamic gamma knife radiosurgery treatment planning system, where the inverse planning problem is solved as a traveling salesman problem combined with constrained least-square optimizations. We have also carried out experimental studies of dynamic gamma knife radiosurgery and showed the following. (1) Dynamic gamma knife radiosurgery is ideally suited for fully automatic inverse planning, where high quality radiosurgery plans can be obtained in minutes of computation. (2) Dynamic radiosurgery plans are more conformal than step-and-shoot plans and can maintain a steep dose gradient (around 13% per mm) between the target tumor volume and the surrounding critical structures. (3) It is possible to prescribe multiple isodose lines with dynamic gamma knife radiosurgery, so that the treatment can cover the periphery of the target volume while escalating the dose for high tumor burden regions. (4) With dynamic gamma knife radiosurgery, one can obtain a family of plans representing a tradeoff between the delivery time and

  15. Dynamic gamma knife radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Luan Shuang; Swanson, Nathan; Chen Zhe [Department of Computer Science, University of New Mexico, Albuquerque, NM 87131 (United States); Ma Lijun [Department of Radiation Oncology, University of California San Francisco, San Francisco, CA 94143 (United States)], E-mail: sluan@cs.unm.edu, E-mail: nate@cs.unm.edu, E-mail: zchen@cs.unm.edu, E-mail: lijunma@radonc.ucsf.edu

    2009-03-21

    Gamma knife has been the treatment of choice for various brain tumors and functional disorders. Current gamma knife radiosurgery is planned in a 'ball-packing' approach and delivered in a 'step-and-shoot' manner, i.e. it aims to 'pack' the different sized spherical high-dose volumes (called 'shots') into a tumor volume. We have developed a dynamic scheme for gamma knife radiosurgery based on the concept of 'dose-painting' to take advantage of the new robotic patient positioning system on the latest Gamma Knife C(TM) and Perfexion(TM) units. In our scheme, the spherical high dose volume created by the gamma knife unit will be viewed as a 3D spherical 'paintbrush', and treatment planning reduces to finding the best route of this 'paintbrush' to 'paint' a 3D tumor volume. Under our dose-painting concept, gamma knife radiosurgery becomes dynamic, where the patient moves continuously under the robotic positioning system. We have implemented a fully automatic dynamic gamma knife radiosurgery treatment planning system, where the inverse planning problem is solved as a traveling salesman problem combined with constrained least-square optimizations. We have also carried out experimental studies of dynamic gamma knife radiosurgery and showed the following. (1) Dynamic gamma knife radiosurgery is ideally suited for fully automatic inverse planning, where high quality radiosurgery plans can be obtained in minutes of computation. (2) Dynamic radiosurgery plans are more conformal than step-and-shoot plans and can maintain a steep dose gradient (around 13% per mm) between the target tumor volume and the surrounding critical structures. (3) It is possible to prescribe multiple isodose lines with dynamic gamma knife radiosurgery, so that the treatment can cover the periphery of the target volume while escalating the dose for high tumor burden regions. (4) With dynamic gamma knife radiosurgery, one can

  16. Automatic identification in mining

    Energy Technology Data Exchange (ETDEWEB)

    Puckett, D; Patrick, C [Mine Computers and Electronics Inc., Morehead, KY (United States)

    1998-06-01

    The feasibility of monitoring the locations and vital statistics of equipment and personnel in surface and underground mining operations has increased with advancements in radio frequency identification (RFID) technology. This paper addresses the use of RFID technology, which is relatively new to the mining industry, to track surface equipment in mine pits, loading points and processing facilities. Specific applications are discussed, including both simplified and complex truck tracking systems and an automatic pit ticket system. This paper concludes with a discussion of the future possibilities of using RFID technology in mining including monitoring heart and respiration rates, body temperatures and exertion levels; monitoring repetitious movements for the study of work habits; and logging air quality via personnel sensors. 10 refs., 5 figs.

  17. Searching the Gamma-Ray Sky for Counterparts to Gravitational Wave Sources Fermi Gamma-Ray Burst Monitor and Large Area Telescope Observations of LVT151012 and GW151226

    Science.gov (United States)

    Racusin, J. L.; Burns, E.; Goldstein, A.; Connaughton, V.; Wilson-Hodge, C. A.; Jenke, P.; Blackburn, L.; Briggs, M. S.; Broida, J.; Camp, J.; hide

    2017-01-01

    We present the Fermi Gamma-ray Burst Monitor (GBM) and Large Area Telescope (LAT) observations of the LIGO binary black hole merger event GW151226 and candidate LVT151012. At the time of the LIGO triggers on LVT151012 and GW151226, GBM was observing 68% and 83% of the localization regions, and LAT was observing 47% and 32%, respectively. No candidate electromagnetic counterparts were detected by either the GBM or LAT. We present a detailed analysis of the GBM and LAT data over a range of timescales from seconds to years, using automated pipelines and new techniques for characterizing the flux upper bounds across large areas of the sky. Due to the partial GBM and LAT coverage of the large LIGO localization regions at the trigger times for both events, differences in source distances and masses, as well as the uncertain degree to which emission from these sources could be beamed, these non-detections cannot be used to constrain the variety of theoretical models recently applied to explain the candidate GBM counterpart to GW150914.

  18. Production of beta-gamma coincidence spectra of individual radioxenon isotopes for improved analysis of nuclear explosion monitoring data

    Science.gov (United States)

    Haas, Derek Anderson

    Radioactive xenon gas is a fission product released in the detonation of nuclear devices that can be detected in atmospheric samples far from the detonation site. In order to improve the capabilities of radioxenon detection systems, this work produces beta-gamma coincidence spectra of individual isotopes of radioxenon. Previous methods of radioxenon production consisted of the removal of mixed isotope samples of radioxenon gas released from fission of contained fissile materials such as 235U. In order to produce individual samples of the gas, isotopically enriched stable xenon gas is irradiated with neutrons. The detection of the individual isotopes is also modeled using Monte Carlo simulations to produce spectra. The experiment shows that samples of 131mXe, 133 Xe, and 135Xe with a purity greater than 99% can be produced, and that a sample of 133mXe can be produced with a relatively low amount of 133Xe background. These spectra are compared to models and used as essential library data for the Spectral Deconvolution Analysis Tool (SDAT) to analyze atmospheric samples of radioxenon for evidence of nuclear events.

  19. Monitoring of health of trees by gamma-ray tomographic scanners and the first Kanpur error theorem

    International Nuclear Information System (INIS)

    Verma, Ruchi; Razdan, Mayuri; Quraishi, A.M.; Munshi, Prabhat

    2004-01-01

    CT scanners produce nondestructively images of a given cross-section with the help of radiation source-detector system and a suitable tomographic reconstruction algorithm. These CT images have inherent error associated with them and for unknown objects it is not possible to calculate it directly. Careful application of the first Kanpur theorem, however, gives an indirect estimate of the inaccuracy of these images. An interesting outcome of this theorem is monitoring of health of trees. (author)

  20. Detoxification with titration and tapering in gamma-hydroxybutyrate (GHB) dependent patients: The Dutch GHB monitor project.

    Science.gov (United States)

    Dijkstra, Boukje A G; Kamal, Rama; van Noorden, Martijn S; de Haan, Hein; Loonen, Anton J M; De Jong, Cor A J

    2017-01-01

    Gamma-hydroxybutyrate (GHB) detoxification procedures have been insufficiently studied for effectiveness and safety. Based on case reports, benzodiazepines are generally regarded as first-choice agents in GHB detoxification. Detoxification by titration and tapering (DeTiTap) with pharmaceutical GHB in an open-label consecutive case series of 23 GHB-dependent patients showed to be feasible, effective and safe. This study further explored the feasibility, effectiveness and safety of this detoxification procedure in a large group of patients. A large observational multicenter study was carried out in six addiction treatment centers in the Netherlands. GHB-dependent inpatients (229 unique patients, 274 admissions) were titrated on and tapered off with pharmaceutical GHB. Successful detoxification was achieved in 85% of cases. Detoxification was carried out in 12.5days in most patients. The DeTiTap procedure proved to be feasible and significantly reduced the experienced withdrawal symptoms and craving (p≤0.001). Several symptoms were found to influence the course of subjective withdrawal symptoms. During detoxification, psychological symptoms such as depression, anxiety, and stress decreased (p≤0.05). The main complications were hypertension and anxiety. Six patients were sent to the general hospital for observation, but all six were able to continue detoxification in the addiction treatment centers. Most patients (69%) relapsed within three months after detoxification. The DeTiTap procedure using pharmaceutical GHB seems a safe alternative to benzodiazepines as a GHB detoxification procedure. However, the high relapse rates warrant further investigation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. Gamma background radiation monitoring results (1990-95) in the environs around IRE OSCOM, Orissa using TLDs

    Energy Technology Data Exchange (ETDEWEB)

    Mehta, N K; Bapat, V N; Nambi, K S.V. [Bhabha Atomic Research Centre, Mumbai (India). Environmental Assessment Div.; Saha, S C [Bhabha Atomic Research Centre, Bombay (India). Health Physics Div.

    1997-09-01

    Quarterly environmental radiation monitoring data using TLDs in about 28 locations in and around IRE-OSCOM covering a six year period 1990-95 is presented in the report. While the indoor radiation levels in beach areas having monazite deposits recorded annual average of 653{+-}230 mR/y, that in IRE residential colony gave a value of 240 {+-}30 mR/y. The radiation levels recorded inside the OSCOM plant are well within the limits prescribed for occupational radiation exposures. (author). 3 refs., 7 figs., 1 tab.

  2. Gamma background radiation monitoring results (1990-95) in the environs around IRE OSCOM, Orissa using TLDs

    International Nuclear Information System (INIS)

    Mehta, N.K.; Bapat, V.N.; Nambi, K.S.V.; Saha, S.C.

    1997-01-01

    Quarterly environmental radiation monitoring data using TLDs in about 28 locations in and around IRE-OSCOM covering a six year period 1990-95 is presented in the report. While the indoor radiation levels in beach areas having monazite deposits recorded annual average of 653±230 mR/y, that in IRE residential colony gave a value of 240 ±30 mR/y. The radiation levels recorded inside the OSCOM plant are well within the limits prescribed for occupational radiation exposures. (author). 3 refs., 7 figs., 1 tab

  3. Evaluation of personal dose equivalent 'HP(d)' in a external individual monitoring system for X and gamma radiation

    International Nuclear Information System (INIS)

    Santoro, C.; Antonio Filho, J.; Santos, M.A.P.

    2007-01-01

    The good of individual monitoring for external radiation is the assessment of occupational exposure from X and γ radiations in order to assure that the radiological conditions of the workplace are acceptable, safe and satisfactory. The evaluation of radiations doses for workers must not exceed dose limits specified for workers, according to national regulatory agencies. Nowadays, there are two external monitoring systems in use, both based on ICRU definitions. In the conventional system, the workers doses are evaluated in terms of Hx. The personal dosimeter is worn over chest surface and it is calibrated in function of air kerma. In the new system, the workers doses are evaluated in terms of HP(d) and the personal dosimeter is calibrated in function of phantom doses. The aim of this paper is to adapt an external dosimetry laboratory (based on photographic dosimetry) to evaluate the personal dosimeters in terms of HP(d). In this way, a simple methodology, based on linear programming, was utilized. In this adaptation, calibration curves were obtained for radiation qualities (W and N series) described by International Organization for Standardization (ISO 4037-1, 1995). These calibration curves offer a better accuracy on dose determinations and energy below 140 keV, improving the quality of service rendered the society. (author)

  4. Simultaneous validation of the Grandway MD2301 digital automatic blood pressure monitor by the British Hypertension Society and the Association for the Advancement of Medical Instrumentation/the International Organization for Standardization protocols.

    Science.gov (United States)

    Huang, Jinhua; Wang, Yun; Liu, Zhaoying; Wang, Yuling

    2017-02-01

    The aim of this study was to determine the accuracy of the Grandway MD2301 digital automatic blood pressure monitor by the British Hypertension Society (BHS) and the Association for the Advancement of Medical Instrumentation (AAMI)/the International Organization for Standardization (ISO) protocols. A total of 85 participants were included for evaluation based on the requirements of the BHS and the AAMI/ISO protocols. The validation procedure and data analysis followed the protocols precisely. The device achieved A/A grading for the BHS protocol and maintained A/A grading throughout the low, medium and high blood pressure ranges. The device also fulfilled the requirement of the AAMI/ISO protocol with device-observer differences of -0.9±5.6 and 0.8±5.2 mmHg for systolic and diastolic blood pressure, respectively, for criterion 1, and -0.9±4.7 and 0.8±4.2 mmHg, respectively, for criterion 2. The Grandway MD2301 digital automatic blood pressure monitor achieved A/A grade of the BHS protocol and passed the requirements of the AAMI/ISO protocol in adults.

  5. Validation of the Andon KD-5917 automatic upper arm blood pressure monitor, for clinic use and self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Guo, Wan-Gang; Li, Bing-Ling; He, Yong; Xue, Yu-Sheng; Wang, Hai-Yan; Zheng, Qiang-Sun; Xiang, Ding-Cheng

    2014-08-01

    To validate the Andon KD-5917 automatic upper arm blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Sequential same-left-arm measurements of systolic blood pressure (SBP) and diastolic blood pressure (DBP) were obtained in 33 participants using the mercury sphygmomanometer and the test device. According to the validation protocol, 99 pairs of test device and reference blood pressure measurements (three pairs for each of the 33 participants) were obtained in the study. The device produced 73, 98, and 99 measurements within 5, 10, and 15 mmHg for SBP and 86, 98, and 99 for DBP, respectively. The mean ± SD device-observer difference was 3.07 ± 3.68 mmHg for SBP and -0.89 ± 3.72 mmHg for DBP. The number of patients with two or three of the device-observer difference within 5 mmHg was 26 for SBP and 29 for DBP, and no patient had a device-observer difference within 5 mmHg. The Andon KD-5917 automatic upper arm blood pressure monitor can be recommended for clinical use and self-measurement in an adult population on the basis of the European Society of Hypertension International Protocol revision 2010.

  6. EEG data during open heart surgery. Their automatic analysis related to anesthetic parameters and its use in peroperative monitoring of cerebral function

    NARCIS (Netherlands)

    Simons, A.J.R.; Pronk, R.A.F.

    1982-01-01

    It is generally agreed upon by experts that EEG monitoring of brain function during open heart surgery is of the utmost importance in preventing postoperative neurological and psychopathological consequences. Up to now, however, this monitoring has not been performed on a large scale: (1) it is a

  7. 10 μ m-thick four-quadrant transmissive silicon photodiodes for beam position monitor application: electrical characterization and gamma irradiation effects

    Science.gov (United States)

    Rafí, J. M.; Pellegrini, G.; Quirion, D.; Hidalgo, S.; Godignon, P.; Matilla, O.; Juanhuix, J.; Fontserè, A.; Molas, B.; Pothin, D.; Fajardo, P.

    2017-01-01

    Silicon photodiodes are very useful devices as X-ray beam monitors in synchrotron radiation beamlines. Owing to Si absorption, devices thinner than 10 μ m are needed to achieve transmission over 90% for energies above 10 keV . In this work, new segmented four-quadrant diodes for beam alignment purposes are fabricated on both ultrathin (10 μ m-thick) and bulk silicon substrates. Four-quadrant diodes implementing different design parameters as well as auxiliary test structures (single diodes and MOS capacitors) are studied. An extensive electrical characterization, including current-voltage (I-V) and capacitance-voltage (C-V) techniques, is carried out on non-irradiated and gamma-irradiated devices up to 100 Mrad doses. Special attention is devoted to the study of radiation-induced charge build-up in diode interquadrant isolation dielectric, as well as its impact on device interquadrant resistance. Finally, the devices have been characterized with an 8 keV laboratory X-ray source at 108 ph/s and in BL13-XALOC ALBA Synchroton beamline with 1011 ph/s and energies from 6 to 16 keV . Sensitivity, spatial resolution and uniformity of the devices have been evaluated.

  8. Sequential Analysis of Gamma Spectra

    International Nuclear Information System (INIS)

    Fayez-Hassan, M.; Hella, Kh.M.

    2009-01-01

    This work shows how easy one can deal with a huge number of gamma spectra. The method can be used for radiation monitoring. It is based on the macro feature of the windows XP connected to QBASIC software. The routine was used usefully in generating accurate results free from human errors. One hundred measured gamma spectra were fully analyzed in 10 minutes using our fast and automated method controlling the Genie 2000 gamma acquisition analysis software.

  9. Expert system for the automatic analysis of the Eddy current signals from the monitoring of vapor generators of a PWR type reactor

    International Nuclear Information System (INIS)

    Benoist, P.; David, B.; Pigeon, M.

    1990-01-01

    An expert system for the automatic analysis of signals from Eddy currents is presented. The system was developed in order to detect and analyse the defects which may exist in vapor generators. The extraction of a signal from a high level background noise is possible. The organization of the work during the system's development, the results of the technique for the extraction of the signal from the background noise, and an example concerning the interpretation of the signal from a defect are presented [fr

  10. Recent activities on clearance in IAEA and clearance automatic laser inspection system (CLALIS)

    International Nuclear Information System (INIS)

    Hattori, Takatoshi; Sasaki, Michiya

    2005-01-01

    Exemption levels for bulk amounts of materials have been described in RS-G-1.7 published as a safety guide in IAEA on August 2004. In Japan, the Nuclear Safety Commission adopted the RS-G-1.7 values as Japanese clearance levels after the careful review of dose assessment results. After completing revises of regulatory laws in relation to clearance level, solid wastes from decommissioning and operating nuclear power plants will be targets of clearance inspection. In CRIEPI, Clearance Automatic Laser Inspection System (CLALIS) has been developed, which can give high reliability and objectivity to the measurement data. The CLALIS is a new monitoring system coupling with 3D laser shape measurement, Monte-Carlo calculation and gamma measurement techniques, which can keep a high accuracy in the measurement data using an automatic correction technique for self-shielding effects of metal waste itself and is expected to apply as a practical use in actual clearance inspections. (author)

  11. Automatic alignment of radionuclide images

    International Nuclear Information System (INIS)

    Barber, D.C.

    1982-01-01

    The variability of the position, dimensions and orientation of a radionuclide image within the field of view of a gamma camera hampers attempts to analyse the image numerically. This paper describes a method of using a set of training images of a particular type, in this case right lateral brain images, to define the likely variations in the position, dimensions and orientation for that type of image and to provide alignment data for a program that automatically aligns new images of the specified type to a standard position, size and orientation. Examples are given of the use of this method on three types of radionuclide image. (author)

  12. Gamma Knife

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Gamma Knife Gamma Knife® is a radiation therapy that uses computerized ... If you're scheduled for radiation therapy using Gamma Knife®, a treatment team consisting of a radiation ...

  13. Simultaneous neutron and gamma spectrum adjustment

    International Nuclear Information System (INIS)

    Remec, I.

    1996-01-01

    The spectrum adjustment procedure was extended to simultaneous neutron and gamma spectrum adjustment, and the feasibility of this technique is demonstrated in the analysis of HFIR dosimetry experiments. Conditions in which gamma rays may contribute considerably to radiation damage in steels are discussed. Beryllium helium accumulation fluence monitors (HAFMs) were found to be good monitors in gamma fields of intensities high enough to contribute to steel embrittlement. Use of 237 Np, 238 U, and 9 Be HAFM as gamma dosimeters is proposed for high-dose irradiations in high-energy, high-intensity gamma fields

  14. Semi-automatic logarithmic converter of logs

    International Nuclear Information System (INIS)

    Gol'dman, Z.A.; Bondar's, V.V.

    1974-01-01

    Semi-automatic logarithmic converter of logging charts. An original semi-automatic converter was developed for use in converting BK resistance logging charts and the time interval, ΔT, of acoustic logs from a linear to a logarithmic scale with a specific ratio for subsequent combining of them with neutron-gamma logging charts in operative interpretation of logging materials by a normalization method. The converter can be used to increase productivity by giving curves different from those obtained in manual, pointwise processing. The equipment operates reliably and is simple in use. (author)

  15. Integrated smart bearings for next generation aero-engines Part 1: Development of a sensor suite for automatic bearing health monitoring

    OpenAIRE

    Bashir, Imran; Wang, Ling; Harvey, Terence; Zaghari, Bahareh; Weddell, Alexander; White, Neil

    2017-01-01

    The development of smart bearing solutions will contribute to increased aircraft engine reliability, allowing the early detection of bearing failure through robust health monitoring. This project aims to develop intelligent bearing systems for an Ultra High Propulsion Efficiency (UHPE) ground test demonstrator, where a fully integrated self-powered wireless sensing system will be developed for future aircraft. This paper provides a comprehensive review of the state-of-the-art smart bearing te...

  16. Modular gamma systems

    International Nuclear Information System (INIS)

    Millegan, D.R.; Nixon, K.V.

    1982-01-01

    Nuclear safeguards requires sensitive, easily operated instruments for rapid inspection of personnel and vehicles to ensure that no uranium or plutonium is being diverted. Two portable gamma-ray detection systems have been developed. The Modular Gamma System (MGS) is very sensitive and two or more systems can be connected for even better performance. The multiunit configuration can be deployed by motor vehicle for search of large areas too extensive to search on foot. The Programmable Rate Monitor (PRM) is less sensitive but much smaller and therefore is more suitable for search of vehicles, personnel, or smaller areas. The PRM is programmable, which implements measurement and alarm algorithms for individual applications

  17. Implementation of an Automatic System for the Monitoring of Start-up and Operating Regimes of the Cooling Water Installations of a Hydro Generator

    Directory of Open Access Journals (Sweden)

    Ioan Pădureanu

    2015-07-01

    Full Text Available The safe operation of a hydro generator depends on its thermal regime, the basic conditions being that the temperature in the stator winding fall within the limits of the insulation class. As the losses in copper depend on the square current in the stator winding, it is necessary that the cooling water debit should be adapted to the values of these losses, so that the winding temperature falls within the range of the values prescribed in the specifications. This paper presents an efficient solution of commanding and monitoring the water cooling installations of two high-power hydro generators.

  18. Automatic online and real-time tumour motion monitoring during stereotactic liver treatments on a conventional linac by combined optical and sparse monoscopic imaging with kilovoltage x-rays (COSMIK)

    Science.gov (United States)

    Bertholet, Jenny; Toftegaard, Jakob; Hansen, Rune; Worm, Esben S.; Wan, Hanlin; Parikh, Parag J.; Weber, Britta; Høyer, Morten; Poulsen, Per R.

    2018-03-01

    The purpose of this study was to develop, validate and clinically demonstrate fully automatic tumour motion monitoring on a conventional linear accelerator by combined optical and sparse monoscopic imaging with kilovoltage x-rays (COSMIK). COSMIK combines auto-segmentation of implanted fiducial markers in cone-beam computed tomography (CBCT) projections and intra-treatment kV images with simultaneous streaming of an external motion signal. A pre-treatment CBCT is acquired with simultaneous recording of the motion of an external marker block on the abdomen. The 3-dimensional (3D) marker motion during the CBCT is estimated from the auto-segmented positions in the projections and used to optimize an external correlation model (ECM) of internal motion as a function of external motion. During treatment, the ECM estimates the internal motion from the external motion at 20 Hz. KV images are acquired every 3 s, auto-segmented, and used to update the ECM for baseline shifts between internal and external motion. The COSMIK method was validated using Calypso-recorded internal tumour motion with simultaneous camera-recorded external motion for 15 liver stereotactic body radiotherapy (SBRT) patients. The validation included phantom experiments and simulations hereof for 12 fractions and further simulations for 42 fractions. The simulations compared the accuracy of COSMIK with ECM-based monitoring without model updates and with model updates based on stereoscopic imaging as well as continuous kilovoltage intrafraction monitoring (KIM) at 10 Hz without an external signal. Clinical real-time tumour motion monitoring with COSMIK was performed offline for 14 liver SBRT patients (41 fractions) and online for one patient (two fractions). The mean 3D root-mean-square error for the four monitoring methods was 1.61 mm (COSMIK), 2.31 mm (ECM without updates), 1.49 mm (ECM with stereoscopic updates) and 0.75 mm (KIM). COSMIK is the first combined kV/optical real-time motion

  19. Xe isotope detection and discrimination using beta spectroscopy with coincident gamma spectroscopy

    Science.gov (United States)

    Reeder, P. L.; Bowyer, T. W.

    1998-02-01

    Beta spectroscopic techniques show promise of significant improvements for a beta-gamma coincidence counter that is part of a system for analyzing Xe automatically separated from air. The previously developed counting system for 131mXe, 133mXe, 133gXe, and 135gXe can be enhanced to give additional discrimination between these Xe isotopes by using the plastic scintillation sample cell as a beta spectrometer to resolve the conversion electron peaks. The automated system will be a key factor in monitoring the Comprehensive Test Ban Treaty.

  20. Monitoring of mass flux of catalyst FCC in a Cold Pilot Unit by gamma radiation transmission; Monitoramento da taxa de fluxo do catalisador FCC em uma unidade piloto a frio por medicao de transmissao gama

    Energy Technology Data Exchange (ETDEWEB)

    Brito, Marcio Fernando Paixao de

    2014-09-01

    This paper proposes a model for monitoring the mass flow of catalyst FCC - Fluid Catalytic Cracking - in a CPU - Cold Pilot unit - due to the injection of air and solid by gamma radiation transmission. The CPU simplifies the process of FCC, which is represented by the catalyst cycle, and it was constructed of acrylic, so that the flow can be visualized. The CPU consists of riser separation chamber and return column, and simulates the riser reactor of the FCC process. The catalyst is injected into the column back to the base of the riser, an inclined tube, where the compressed air means that there fluidization along the riser. When the catalyst comes in the separation chamber, the solid phase is sent to the return column, and the gas phase exits the system through one of the four cyclones at the top of the separation chamber. The transmission gamma of measures will be made by means of three test sections that have source and detector shielded. Pressure drop in the riser measurements are made through three pressure gauges positioned on the riser. The source used was Am-241 gamma ray with energy of 60 keV, and detector used was a scintillator of NaI (Tl) of 2 {sup x} 2{sup .} Measures the mass flow of catalyst are made by varying the seal of the catalyst, and density of solid in the riser because with the combination of these measures can determine the speed of the catalyst in the riser. The results show that the transmission gamma is a suitable technique for monitoring the flow of catalyst, flow model in CPU is annular, tomography third generation is more appropriate to study the CPU and the density variation in circulation in the CPU decreases linearly with increasing air flow. (author)

  1. Automatic total kidney volume measurement on follow-up magnetic resonance images to facilitate monitoring of autosomal dominant polycystic kidney disease progression.

    Science.gov (United States)

    Kline, Timothy L; Korfiatis, Panagiotis; Edwards, Marie E; Warner, Joshua D; Irazabal, Maria V; King, Bernard F; Torres, Vicente E; Erickson, Bradley J

    2016-02-01

    Renal imaging examinations provide high-resolution information about the anatomic structure of the kidneys and are used to measure total kidney volume (TKV) in autosomal dominant polycystic kidney disease (ADPKD) patients. TKV has become the gold-standard image biomarker for ADPKD progression at early stages of the disease and is used in clinical trials to characterize treatment efficacy. Automated methods to segment the kidneys and measure TKV are desirable because of the long time requirement for manual approaches such as stereology or planimetry tracings. However, ADPKD kidney segmentation is complicated by a number of factors, including irregular kidney shapes and variable tissue signal at the kidney borders. We describe an image processing approach that overcomes these problems by using a baseline segmentation initialization to provide automatic segmentation of follow-up scans obtained years apart. We validated our approach using 20 patients with complete baseline and follow-up T1-weighted magnetic resonance images. Both manual tracing and stereology were used to calculate TKV, with two observers performing manual tracings and one observer performing repeat tracings. Linear correlation and Bland-Altman analysis were performed to compare the different approaches. Our automated approach measured TKV at a level of accuracy (mean difference ± standard error = 0.99 ± 0.79%) on par with both intraobserver (0.77 ± 0.46%) and interobserver variability (1.34 ± 0.70%) of manual tracings. All approaches had excellent agreement and compared favorably with ground-truth manual tracing with interobserver, stereological and automated approaches having 95% confidence intervals ∼ ± 100 mL. Our method enables fast, cost-effective and reproducible quantification of ADPKD progression that will facilitate and lower the costs of clinical trials in ADPKD and other disorders requiring accurate, longitudinal kidney quantification. In addition, it will hasten the routine use of

  2. Environmental radiation monitoring of nuclear sites by thermoluminescent dosimeters (TLD)

    International Nuclear Information System (INIS)

    Duftschmid, K.E.; Strachotinsky, Ch.

    1978-04-01

    The measurement of environmental radiation doses around nuclear facilities requires the detection of few mrem/year. The properties of the automatic TLD-system Harshaw Mod. 2271 for such measurements have been evaluated under practical conditions and optimized techniques derived. The automatic TLD-system is based on LiF dosimeter cards with two crystals providing gamma and beta dose values. Limit of detection defined as three standard deviations of residuel dose is 1,2 mR. Automatic readout combined with electronic data evaluation are especially useful for large monitoring networks. Practical intercomparisons of this dosimeter with bulb-type CaF 2 detectors have been performed showing good agreement of both detector. Although bulb-dosimeters proved to be extremely sensitive with a limit of detection at 0,012 mR which makes them very suitable for very short exposure times, the automatic LiF system is superior in regards of man power requirement if monthly monitoring periods are sufficient. The system has been tested in practice during two international intercomparisons performed by the US Department of Energy - Health and Safety Laboratory New York and the Physikalisch Technische Bundesanstalt Braunschweig, Germany, showing excellent agreement. Furthermore a routine monitoring network consisting of 12 measurement positions around the Research Center Seibersdorf has been operated with this technique since more than two years. (author)

  3. Automatic plasma control in magnetic traps

    International Nuclear Information System (INIS)

    Samojlenko, Y.; Chuyanov, V.

    1984-01-01

    Hot plasma is essentially in thermodynamic non-steady state. Automatic plasma control basically means monitoring deviations from steady state and producing a suitable magnetic or electric field which brings the plasma back to its original state. Briefly described are two systems of automatic plasma control: control with a magnetic field using a negative impedance circuit, and control using an electric field. It appears that systems of automatic plasma stabilization will be an indispensable component of the fusion reactor and its possibilities will in many ways determine the reactor economy. (Ha)

  4. Finding weak points automatically

    International Nuclear Information System (INIS)

    Archinger, P.; Wassenberg, M.

    1999-01-01

    Operators of nuclear power stations have to carry out material tests at selected components by regular intervalls. Therefore a full automaticated test, which achieves a clearly higher reproducibility, compared to part automaticated variations, would provide a solution. In addition the full automaticated test reduces the dose of radiation for the test person. (orig.) [de

  5. A method of automatic data processing in radiometric control

    International Nuclear Information System (INIS)

    Adonin, V.M.; Gulyukina, N.A.; Nemirov, Yu.V.; Mogil'nitskij, M.I.

    1980-01-01

    Described is the algorithm for automatic data processing in gamma radiography of products. Rapidity due to application of recurrent evaluation is a specific feature of the processing. Experimental data of by-line control are presented. The results obtained have shown the applicability of automatic signal processing to the testing under industrial conditions, which would permit to increase the testing efficiency to eliminate the subjectivism in assessment of testing results and to improve working conditions

  6. Estimation of the Vertical Distribution of Radiocesium in Soil on the Basis of the Characteristics of Gamma-Ray Spectra Obtained via Aerial Radiation Monitoring Using an Unmanned Helicopter.

    Science.gov (United States)

    Ochi, Kotaro; Sasaki, Miyuki; Ishida, Mutsushi; Hamamoto, Shoichiro; Nishimura, Taku; Sanada, Yukihisa

    2017-08-17

    After the Fukushima Daiichi Nuclear Power Plant accident, the vertical distribution of radiocesium in soil has been investigated to better understand the behavior of radiocesium in the environment. The typical method used for measuring the vertical distribution of radiocesium is troublesome because it requires collection and measurement of the activity of soil samples. In this study, we established a method of estimating the vertical distribution of radiocesium by focusing on the characteristics of gamma-ray spectra obtained via aerial radiation monitoring using an unmanned helicopter. The estimates are based on actual measurement data collected at an extended farm. In this method, the change in the ratio of direct gamma rays to scattered gamma rays at various depths in the soil was utilized to quantify the vertical distribution of radiocesium. The results show a positive correlation between the abovementioned and the actual vertical distributions of radiocesium measured in the soil samples. A vertical distribution map was created on the basis of this ratio using a simple equation derived from the abovementioned correlation. This technique can provide a novel approach for effective selection of high-priority areas that require decontamination.

  7. Estimation of the Vertical Distribution of Radiocesium in Soil on the Basis of the Characteristics of Gamma-Ray Spectra Obtained via Aerial Radiation Monitoring Using an Unmanned Helicopter

    Science.gov (United States)

    Ochi, Kotaro; Sasaki, Miyuki; Ishida, Mutsushi; Sanada, Yukihisa

    2017-01-01

    After the Fukushima Daiichi Nuclear Power Plant accident, the vertical distribution of radiocesium in soil has been investigated to better understand the behavior of radiocesium in the environment. The typical method used for measuring the vertical distribution of radiocesium is troublesome because it requires collection and measurement of the activity of soil samples. In this study, we established a method of estimating the vertical distribution of radiocesium by focusing on the characteristics of gamma-ray spectra obtained via aerial radiation monitoring using an unmanned helicopter. The estimates are based on actual measurement data collected at an extended farm. In this method, the change in the ratio of direct gamma rays to scattered gamma rays at various depths in the soil was utilized to quantify the vertical distribution of radiocesium. The results show a positive correlation between the abovementioned and the actual vertical distributions of radiocesium measured in the soil samples. A vertical distribution map was created on the basis of this ratio using a simple equation derived from the abovementioned correlation. This technique can provide a novel approach for effective selection of high-priority areas that require decontamination. PMID:28817098

  8. Environmental radioactivity monitoring in Greece

    International Nuclear Information System (INIS)

    Maltezos, A.; Potiriadis, C.; Aravantinos, A.

    1997-01-01

    Greek Atomic Energy Commission (GAEC) is the national organization responsible for the environmental radioactivity measurements in Greece. In order to monitor the radioactivity, 12 stations were placed all over Greece. Each station is equipped with NaI detector, measuring daily the total gamma dose rates. After the Chernobyl experience many countries have installed dense automatic networks, for measuring environmental radioactivity and serving as an early warning systems. In Greece a small telemetric network of two stations was installed in Athens area as a pilot project. Each station consists of two GM detectors (for low and high dose rate respectively). Data are collected for every ten minutes sampling time. Regration time of one hour is obtained. In case of level one and level two alarm states, the sampling time intervals are ten and one minutes respectively. The measurements are obtained by the above stations using the lines of the telephone network, and stored in the central station. Financial support to upgrade the existing telemetric system was assured by the addition of 25 new telemetric stations which will cover madly the northern part bordering to other states with nuclear power plants.In order to complete the network, we plan to add more stations to measure the gamma dose rates spread all over Greece, and also monitor river water. (authors)

  9. Development of an On-Line Uranium Enrichment Monitor

    International Nuclear Information System (INIS)

    Xuesheng, L.; Guorong, L.; Yonggang, Z.; Xueyuan, H. X.-Y.

    2015-01-01

    An on-line enrichment monitor was developed to measure the enrichment of UF6 flowing through the processing pipes in centrifuge uranium enrichment plant. A NaI(Tl) detector was used to measure the count rates of the 186 keV gamma ray emitted from 235U, and the total quantity of uranium was determined from thermodynamic characteristics of gaseous uranium hexafluoride. The results show that the maximum relative standard deviation is less than 1% when the measurement time is 120 s or more and the pressure is more than 2 kPa in the measurement chamber. There are two working models for the monitor. The monitor works normally in the continuous model, When the gas's pressure in the pipe fluctuates greatly, it can work in the intermittent model, and the measurement result is very well. The background of the monitor can be measured automatically periodically. It can control automatically electromagnetic valves open and close, so as to change the gas's quantity in the chamber. It is a kind of unattended and remote monitor, all of data can be transfer to central control room. It should be effective for nuclear materials accountability verifications and materials balance verification at uranium enrichment plant by using the monitor to monitor Uranium enrichment of gaseous uranium hexafluoride in the output end of cascade continuously. (author)

  10. Automation of gamma-therapy

    International Nuclear Information System (INIS)

    Al'bitskij, L.L.; Brikker, I.N.; Bychkov, V.N.; Voronin, V.V.; Mirzoyan, A.R.; Rogozhin, A.S.; Sarkisyan, Yu.Kh.

    1989-01-01

    A system of automated control Aspect-2 was developed for automation of gamma therapy on units of the Rokus series. The system consists of the following hardware and software complexes: a complex of preirradiation preparation Centrator-imitator, a complex Accord for anatomotopographic data coding; a software complex and a gamma-therapeutic complex Rokus-AM. The Centrator-imitator and Rokus-AM complexes are fitted out with built-in microcomputers with specially developed systemic software. The Rokus-AM complex has automatic punch tape programmed control of 9 degrees of freedom of the gamma-unit and treatment table and ensures 5 modes of irradiation: positional, rotating, rotaing-convergent, sectoral rotating-convergent and scanning

  11. An automated measuring system based on gamma spectrometry with HPGe detectors

    International Nuclear Information System (INIS)

    Mala, Helena; Rulik, Petr; Hyza, Miroslav; Dragounova, Lenka; Helebrant, Jan; Hroznicek, Marek; Jelinek, Pavel; Zak, Jan

    2016-01-01

    An automatic system for unattended gamma spectrometric measurements of bulk samples ( “Gamma Automat”, GA) was developed by the National Radiation Protection Institute and Nuvia, Inc. as a part of a research project. The basic parts include a detection system with two HPGe detectors in the lead shielded chambers, sample changer, sample tray and a control unit. The GA enables counting in two geometries: (i) with cylindrical containers (200 ml) either one placed at the detector face or 2-6 placed around the detector or (II) with Marinelli beakers (600 ml). The shelf can accommodate 180 cylindrical containers or 54 Marinelli beakers. Samples are changed by a robotic arm. The sample data and the analysis required are passed to the GA by a matrix code (generated within the laboratory system) located on the lid of a sample container, whence the GA reads information. Spectrometric analysis is performed automatically after the counting. Current status of GA can be remotely monitored. Information about the activities of the GA, measurement completion or failures of the equipment are automatically generated and sent to a mobile phone and the operator PC. A presentation of the GA is available at https://youtu.be/1lQhfo0Fljo. (orig.)

  12. Gamma astronomy

    International Nuclear Information System (INIS)

    Cesarsky, C.; Cesarsky, J.P.

    1986-01-01

    This article overviews the gamma astronomy research. Sources already observed, and what causes to give to them; the galactic radiation and its interpretation; techniques already used and current projects [fr

  13. Gamma Spectroscopy

    NARCIS (Netherlands)

    Niemantsverdriet, J.W.; Butz, Tilman; Ertl, G.; Knözinger, H.; Schüth, F.

    2008-01-01

    No abstract. The sections in this article are 1 Introduction 2 Mössbauer Spectroscopy 3 Time-Differential Perturbed Angular Correlations (TDPAC) 4 Conclusions and Outlook Keywords: Mössbauer spectroscopy; gamma spectroscopy; perturbed angular correlation; TDPAC

  14. Savannah River Plant remote environmental monitoring system

    International Nuclear Information System (INIS)

    Schubert, J.F.

    1987-01-01

    The SRP remote environmental monitoring system consists of separations facilities stack monitors, production reactor stack monitors, twelve site perimeter monitors, river and stream monitors, a geostationary operational environmental satellite (GOES) data link, reactor cooling lake thermal monitors, meteorological tower system, Weather Information and Display (WIND) system computer, and the VANTAGE data base management system. The remote environmental monitoring system when fully implemented will provide automatic monitoring of key stack releases and automatic inclusion of these source terms in the emergency response codes

  15. Several requirements made on the quality of nuclide-specific gamma radiation measuring rigs with germanium detectors for nuclear power plant monitoring

    International Nuclear Information System (INIS)

    Wuensch, K.D.

    1986-01-01

    The measuring set-ups are used for nuclide-specific analysis of all samples from nuclear power plants, i.e. solid, liquid, or gaseous. Depending on the nature of the sample, various requirements made by ordinances and guidelines discussed in detail must be met, relating to emission monitoring, environmental monitoring, system monitoring, room air monitoring, and contamination monitoring. The state-of-the-art is shown emphasizing the resolution and the evaluation scheme. Experience gained in the control of such systems is reported on in brief. The quality of in-service inspections is discussed. (orig./PW) [de

  16. Online Automatic Titration of Chromic Acid in Chromium Plating Solutions and Phosphoric and Sulfuric Acids in Electropolishing Solutions

    National Research Council Canada - National Science Library

    Sopok, Samuel

    1991-01-01

    .... The analytical chemistry literature lacks an adequate online automatic titration method for the monitoring of chromic acid in chromium plating solutions and the monitoring of phosphoric and sulfuric...

  17. Automatic sample changer for neutron activation analysis at CDTN, Brazil

    International Nuclear Information System (INIS)

    Aimore Dutra Neto; Oliveira Pelaes, Ana Clara; Jacimovic, Radojko

    2018-01-01

    An automatic sample changer was recently developed and installed in the Neutron Activation Analysis (NAA) Laboratory. The certified reference material BCR-320R, Channel Sediment, was analysed in order to verify the reliability of the results obtained by NAA, k 0 -standardisation method, using this automatic system during the gamma-ray measurement step. The results were compared to those manually obtained. The values pointed out that the automatic sample changer is working properly. This changer will increase the productiveness of the neutron activation technique applied at Nuclear Technology Development Centre, CDTN/CNEN expanding its competitiveness as an analytical technique in relation to other techniques. (author)

  18. Wide-Field Imaging Telescope-0 (WIT0) with automatic observing system

    Science.gov (United States)

    Ji, Tae-Geun; Byeon, Seoyeon; Lee, Hye-In; Park, Woojin; Lee, Sang-Yun; Hwang, Sungyong; Choi, Changsu; Gibson, Coyne Andrew; Kuehne, John W.; Prochaska, Travis; Marshall, Jennifer L.; Im, Myungshin; Pak, Soojong

    2018-01-01

    We introduce Wide-Field Imaging Telescope-0 (WIT0), with an automatic observing system. It is developed for monitoring the variabilities of many sources at a time, e.g. young stellar objects and active galactic nuclei. It can also find the locations of transient sources such as a supernova or gamma-ray bursts. In 2017 February, we installed the wide-field 10-inch telescope (Takahashi CCA-250) as a piggyback system on the 30-inch telescope at the McDonald Observatory in Texas, US. The 10-inch telescope has a 2.35 × 2.35 deg field-of-view with a 4k × 4k CCD Camera (FLI ML16803). To improve the observational efficiency of the system, we developed a new automatic observing software, KAOS30 (KHU Automatic Observing Software for McDonald 30-inch telescope), which was developed by Visual C++ on the basis of a windows operating system. The software consists of four control packages: the Telescope Control Package (TCP), the Data Acquisition Package (DAP), the Auto Focus Package (AFP), and the Script Mode Package (SMP). Since it also supports the instruments that are using the ASCOM driver, the additional hardware installations become quite simplified. We commissioned KAOS30 in 2017 August and are in the process of testing. Based on the WIT0 experiences, we will extend KAOS30 to control multiple telescopes in future projects.

  19. SRV-automatic handling device

    International Nuclear Information System (INIS)

    Yamada, Koji

    1987-01-01

    Automatic handling device for the steam relief valves (SRV's) is developed in order to achieve a decrease in exposure of workers, increase in availability factor, improvement in reliability, improvement in safety of operation, and labor saving. A survey is made during a periodical inspection to examine the actual SVR handling operation. An SRV automatic handling device consists of four components: conveyor, armed conveyor, lifting machine, and control/monitoring system. The conveyor is so designed that the existing I-rail installed in the containment vessel can be used without any modification. This is employed for conveying an SRV along the rail. The armed conveyor, designed for a box rail, is used for an SRV installed away from the rail. By using the lifting machine, an SRV installed away from the I-rail is brought to a spot just below the rail so that the SRV can be transferred by the conveyor. The control/monitoring system consists of a control computer, operation panel, TV monitor and annunciator. The SRV handling device is operated by remote control from a control room. A trial equipment is constructed and performance/function testing is carried out using actual SRV's. As a result, is it shown that the SRV handling device requires only two operators to serve satisfactorily. The required time for removal and replacement of one SRV is about 10 minutes. (Nogami, K.)

  20. Automatic Fiscal Stabilizers

    Directory of Open Access Journals (Sweden)

    Narcis Eduard Mitu

    2013-11-01

    Full Text Available Policies or institutions (built into an economic system that automatically tend to dampen economic cycle fluctuations in income, employment, etc., without direct government intervention. For example, in boom times, progressive income tax automatically reduces money supply as incomes and spendings rise. Similarly, in recessionary times, payment of unemployment benefits injects more money in the system and stimulates demand. Also called automatic stabilizers or built-in stabilizers.

  1. Automatic differentiation bibliography

    Energy Technology Data Exchange (ETDEWEB)

    Corliss, G.F. [comp.

    1992-07-01

    This is a bibliography of work related to automatic differentiation. Automatic differentiation is a technique for the fast, accurate propagation of derivative values using the chain rule. It is neither symbolic nor numeric. Automatic differentiation is a fundamental tool for scientific computation, with applications in optimization, nonlinear equations, nonlinear least squares approximation, stiff ordinary differential equation, partial differential equations, continuation methods, and sensitivity analysis. This report is an updated version of the bibliography which originally appeared in Automatic Differentiation of Algorithms: Theory, Implementation, and Application.

  2. Field Deployable Gamma Radiation Detectors for DHS Use

    Energy Technology Data Exchange (ETDEWEB)

    Sanjoy Mukhopadhyay

    2007-08-01

    Recently, the Department of Homeland Security (DHS) has integrated all nuclear detection research, development, testing, evaluation, acquisition, and operational support into a single office: the Domestic Nuclear Detection Office (DNDO). The DNDO has specific requirements set for all commercial off-the-shelf and government off-the-shelf radiation detection equipment and data acquisition systems. This article would investigate several recent developments in field deployable gamma radiation detectors that are attempting to meet the DNDO specifications. Commercially available, transportable, handheld radio isotope identification devices (RIID) are inadequate for DHS requirements in terms of sensitivity, resolution, response time, and reach-back capability. The leading commercial vendor manufacturing handheld gamma spectrometer in the United States is Thermo Electron Corporation. Thermo Electron's identiFINDER{trademark}, which primarily uses sodium iodide crystals (3.18 x 2.54cm cylinders) as gamma detectors, has a Full-Width-at-Half-Maximum energy resolution of 7 percent at 662 keV. Thermo Electron has just recently come up with a reach-back capability patented as RadReachBack{trademark} that enables emergency personnel to obtain real-time technical analysis of radiation samples they find in the field. The current project has the goal to build a prototype handheld gamma spectrometer, equipped with a digital camera and an embedded cell phone to be used as an RIID with higher sensitivity, better resolution, and faster response time (able to detect the presence of gamma-emitting radio isotopes within 5 seconds of approach), which will make it useful as a field deployable tool. The handheld equipment continuously monitors the ambient gamma radiation, and, if it comes across any radiation anomalies with higher than normal gamma gross counts, it sets an alarm condition. When a substantial alarm level is reached, the system automatically triggers the saving of relevant

  3. Field Deployable Gamma Radiation Detectors for DHS Use

    International Nuclear Information System (INIS)

    Sanjoy Mukhopadhyay

    2007-01-01

    Recently, the Department of Homeland Security (DHS) has integrated all nuclear detection research, development, testing, evaluation, acquisition, and operational support into a single office: the Domestic Nuclear Detection Office (DNDO). The DNDO has specific requirements set for all commercial off-the-shelf and government off-the-shelf radiation detection equipment and data acquisition systems. This article would investigate several recent developments in field deployable gamma radiation detectors that are attempting to meet the DNDO specifications. Commercially available, transportable, handheld radio isotope identification devices (RIID) are inadequate for DHS requirements in terms of sensitivity, resolution, response time, and reach-back capability. The leading commercial vendor manufacturing handheld gamma spectrometer in the United States is Thermo Electron Corporation. Thermo Electron's identiFINDER(trademark), which primarily uses sodium iodide crystals (3.18 x 2.54cm cylinders) as gamma detectors, has a Full-Width-at-Half-Maximum energy resolution of 7 percent at 662 keV. Thermo Electron has just recently come up with a reach-back capability patented as RadReachBack(trademark) that enables emergency personnel to obtain real-time technical analysis of radiation samples they find in the field. The current project has the goal to build a prototype handheld gamma spectrometer, equipped with a digital camera and an embedded cell phone to be used as an RIID with higher sensitivity, better resolution, and faster response time (able to detect the presence of gamma-emitting radio isotopes within 5 seconds of approach), which will make it useful as a field deployable tool. The handheld equipment continuously monitors the ambient gamma radiation, and, if it comes across any radiation anomalies with higher than normal gamma gross counts, it sets an alarm condition. When a substantial alarm level is reached, the system automatically triggers the saving of relevant

  4. The automatic liquid nitrogen filling system for GDA detectors

    Indian Academy of Sciences (India)

    . Abstract. An indigenously developed automatic liquid nitrogen (LN2) filling system has been installed in gamma detector array (GDA) facility at Nuclear Science Centre. Electro-pneumatic valves are used for filling the liquid nitrogen into the ...

  5. Gamma camera

    International Nuclear Information System (INIS)

    Berninger, W.H.

    1975-01-01

    The light pulse output of a scintillator, on which incident collimated gamma rays impinge, is detected by an array of photoelectric tubes each having a convexly curved photocathode disposed in close proximity to the scintillator. Electronic circuitry connected to outputs of the phototubes develops the scintillation event position coordinate electrical signals with good linearity and with substantial independence of the spacing between the scintillator and photocathodes so that the phototubes can be positioned as close to the scintillator as is possible to obtain less distortion in the field of view and improved spatial resolution as compared to conventional planar photocathode gamma cameras

  6. Automatic produce quality monitoring in Reefer containers

    NARCIS (Netherlands)

    Lukasse, L.J.S.; Sanders, M.G.; Kramer, de J.E.

    2003-01-01

    Current day perishable supply chains require intermediate points for manual produce quality inspection. Over the last decade international seatransport of fruit and vegetables in reefer containers has grown tremendously. Reefer containers may completely close the cold chain only if produce quality

  7. Automatic vehicle counting system for traffic monitoring

    Science.gov (United States)

    Crouzil, Alain; Khoudour, Louahdi; Valiere, Paul; Truong Cong, Dung Nghy

    2016-09-01

    The article is dedicated to the presentation of a vision-based system for road vehicle counting and classification. The system is able to achieve counting with a very good accuracy even in difficult scenarios linked to occlusions and/or presence of shadows. The principle of the system is to use already installed cameras in road networks without any additional calibration procedure. We propose a robust segmentation algorithm that detects foreground pixels corresponding to moving vehicles. First, the approach models each pixel of the background with an adaptive Gaussian distribution. This model is coupled with a motion detection procedure, which allows correctly location of moving vehicles in space and time. The nature of trials carried out, including peak periods and various vehicle types, leads to an increase of occlusions between cars and between cars and trucks. A specific method for severe occlusion detection, based on the notion of solidity, has been carried out and tested. Furthermore, the method developed in this work is capable of managing shadows with high resolution. The related algorithm has been tested and compared to a classical method. Experimental results based on four large datasets show that our method can count and classify vehicles in real time with a high level of performance (>98%) under different environmental situations, thus performing better than the conventional inductive loop detectors.

  8. An Automatic System for Elevator Monitoring

    OpenAIRE

    Md. Haidar Sharif; Ibrahim Furkan Ince

    2015-01-01

    An elevator is a conveyor device or transport equipment that moves people or goods between floors or levels or decks of a building, vessel, or other structures. It has become a part and parcel of modern life in developed countries. The number of floors in high buildings, skyscrapers, and towers generate the usage of elevators. If it is simply assumed that each floor has at least two elevators in a thirty-floor building, people call the elevators in each floor even they are already occupied in...

  9. Neural Bases of Automaticity

    Science.gov (United States)

    Servant, Mathieu; Cassey, Peter; Woodman, Geoffrey F.; Logan, Gordon D.

    2018-01-01

    Automaticity allows us to perform tasks in a fast, efficient, and effortless manner after sufficient practice. Theories of automaticity propose that across practice processing transitions from being controlled by working memory to being controlled by long-term memory retrieval. Recent event-related potential (ERP) studies have sought to test this…

  10. Automatic control systems engineering

    International Nuclear Information System (INIS)

    Shin, Yun Gi

    2004-01-01

    This book gives descriptions of automatic control for electrical electronics, which indicates history of automatic control, Laplace transform, block diagram and signal flow diagram, electrometer, linearization of system, space of situation, state space analysis of electric system, sensor, hydro controlling system, stability, time response of linear dynamic system, conception of root locus, procedure to draw root locus, frequency response, and design of control system.

  11. Automatic Camera Control

    DEFF Research Database (Denmark)

    Burelli, Paolo; Preuss, Mike

    2014-01-01

    Automatically generating computer animations is a challenging and complex problem with applications in games and film production. In this paper, we investigate howto translate a shot list for a virtual scene into a series of virtual camera configurations — i.e automatically controlling the virtual...

  12. Automatic differentiation of functions

    International Nuclear Information System (INIS)

    Douglas, S.R.

    1990-06-01

    Automatic differentiation is a method of computing derivatives of functions to any order in any number of variables. The functions must be expressible as combinations of elementary functions. When evaluated at specific numerical points, the derivatives have no truncation error and are automatically found. The method is illustrated by simple examples. Source code in FORTRAN is provided

  13. Gamma irradiation treatment of secondary sewage effluent

    International Nuclear Information System (INIS)

    Vajdic, A.H.

    The operation and monitoring of a pilot scale Co-60 gamma irradiation unit treating secondary sewage effluent is described. The disinfecting efficiency of the unit is compared to that of an experimental 'ideal' chlorination unit and to the plant chlorination process. A cost estimate for disinfection by gamma irradiation on a full plant scale is included. (author)

  14. Space-time analysis of the Seismic Waves propagation and World Wide Lightning Location Network data association with the Terrestrial Gamma-ray Flashes detected by the Fermi Gamma-ray Burst Monitor

    International Nuclear Information System (INIS)

    Sorokin, L.

    2017-01-01

    The natural high intensity sub-millisecond electromagnetic pulses associated with seismic waves from earthquakes can trigger +CG, -CG and IC lightning discharges, transient luminous events (TLEs) and non luminous events as TGFS. The lightning discharges with higher peak currents are more probable during the moments when seismic waves from earthquakes pass through a place of lightning. Huge charge transfer of triggered +CG, -CG and IC lightning discharges can radiate powerful electromagnetic emission. Space-time analysis of the seismic wave’s propagation and WWLLN data was done together with the second Fermi GBM Terrestrial Gamma-ray Flashes (TGF) Catalog. A total number of 1203 events from the WWLLN associations table were associated with the entrance the exact seismic waves from earthquakes in the place of lightning. Only 11 events from 1214 associations were rejected. After that the full list of 1049 TGFs has been checked out. As the result the 1038 TGFS has been associated with earthquakes. Among them 42 events with time difference exceeding ±100 sec were found. As the result 996 events get inside the time interval for the space-time analysis ±100 sec, they correspond to 95% from the total number of 1049 TGFS. The probability density function for the Time difference data was calculated and more preferably can be explained by the probability density functions of Cauchy distribution. The Phases of Seismic Waves and earthquakes magnitude associated with selected 996 TGFS from WWLLN associations table were studied. (author)

  15. Background gamma radiation monitoring of three clusters of villages surrounding Mohuldih, Banduhurang and Bagjata villages, the proposed uranium mining areas in Singhbhum, Jharkhand

    International Nuclear Information System (INIS)

    Chougaonkar, M.P.; Puranik, V.D.; Singh, Prashant

    2008-01-01

    Generation of power is a fundamental catalyst to the social and economic development of a country. India needs more power in order to have a strong industrial base and for infrastructure development. With this in view, there has been an emphasis on nuclear power as an alternative source in the field of electricity generation as the nuclear power can be an effective tool in reducing stress on the environment. The Singhbhum district in the state of Jharkhand in India has been known to have deposits of uranium and uranium mines like Jaduguda, Narwapahar, Bhatin etc have been operating in the region. With the increased requirement of electricity and hence suitable fuel, few more sites are proposed to mine uranium in the region. The sites proposed are near the villages of Mohuldih, Banduhurang and Bagjata and are proposed to be open cast mines. These areas of Singhbhum are not economically advanced areas. By and large, the population is poor and there are existing problems like malnutrition and poor health. The activities of mining and the associated developments in the region are expected to improve the economic condition of the residents either through direct employment in the mining facilities, or by indirect gains due to infrastructural developments in the region. In order to assess the impact of the mining operations on the environment and the population as well, it is necessary that the pre-operational survey be carried out in the regions in question. As is the practice, a complete pre-operational survey of the physical, chemical and environmental parameters has been carried out in the region. Background gamma radiation survey was also carried out, using the thermo luminescent dosimetry technique, to obtain the preoperational levels prevalent in the regions. This paper gives the results of the baseline background gamma radiation survey in the region. It was observed that the general gamma background levels of the areas, as measured using TLDs, was 1.36 ± 0.41 m

  16. Computerized automatic tip scanning operation

    International Nuclear Information System (INIS)

    Nishikawa, K.; Fukushima, T.; Nakai, H.; Yanagisawa, A.

    1984-01-01

    In BWR nuclear power stations the Traversing Incore Probe (TIP) system is one of the most important components in reactor monitoring and control. In previous TIP systems, however, operators have suffered from the complexity of operation and long operation time required. The system presented in this paper realizes the automatic operation of the TIP system by monitoring and driving it with a process computer. This system significantly reduces the burden on customer operators and improves plant efficiency by simplifying the operating procedure, augmenting the accuracy of the measured data, and shortening operating time. The process computer is one of the PODIA (Plant Operation by Displayed Information Automation) systems. This computer transfers control signals to the TIP control panel, which in turn drives equipment by microprocessor control. The process computer contains such components as the CRT/KB unit, the printer plotter, the hard copier, and the message typers required for efficient man-machine communications. Its operation and interface properties are described

  17. Gamma camera

    International Nuclear Information System (INIS)

    Tschunt, E.; Platz, W.; Baer, Ul; Heinz, L.

    1978-01-01

    A gamma camera has a plurality of exchangeable collimators, one of which is replaceably mounted in the ray inlet opening of the camera, while the others are placed on separate supports. Supports are swingably mounted upon a column one above the other

  18. Gamma camera

    International Nuclear Information System (INIS)

    Schlosser, P.A.; Steidley, J.W.

    1980-01-01

    The design of a collimation system for a gamma camera for use in nuclear medicine is described. When used with a 2-dimensional position sensitive radiation detector, the novel system can produce superior images than conventional cameras. The optimal thickness and positions of the collimators are derived mathematically. (U.K.)

  19. Radiation monitoring: Quarterly report for the Greater Manchester Fire and Civil Defence Authority and the Manchester Area Pollution Advisory Council. Manchester Area Gamma Radiation Air Monitoring System (MANAGRAMS): report covering period of 3 months 01/07/1996 to 30/09/1996

    International Nuclear Information System (INIS)

    1996-01-01

    Gamma radiation monitoring data from ten outstations in the Manchester area for the period 01/07/1996 to 30/09/1996 are presented. For each station there is a summary table, a background radiation graph showing 6 hour mean levels and a wind rose graph showing the direction of the wind as a percentage of the total. A line graph comparison between stations is provided for the background 6 hour mean levels and a bar chart comparison of total dose during the reporting period. Graphs of barometric pressure and temperature taken from extra sensors at the Trafford station are also presented. (UK)

  20. Radiation monitoring. Quarterly report for the Greater Manchester Fire and Civil Defence Authority and the Manchester Area Pollution Advisory Council. Manchester Area Gamma Radiation Air Monitoring System (MANAGRAMS), report covering period of 3 months 01/04/1997 to 30/06/1997

    International Nuclear Information System (INIS)

    1997-01-01

    Gamma radiation monitoring data from ten outstations in the Manchester area are presented. For each station there is a summary table, a background radiation graph showing 6 hour mean levels and a windrose graph showing the direction of the wind as a percentage of the total. A line graph comparison between stations is provided for the background 6 hour mean levels and a bar chart comparison of total dose. Graphs of temperature and barometric pressure taken from extra sensors at the Trafford station are presented. (Author)

  1. ATLAS fast physics monitoring

    Indian Academy of Sciences (India)

    2012-11-16

    Nov 16, 2012 ... laboration has set up a framework to automatically process the ... ing (FPM) is complementary to data quality monitoring as problems may ... the full power of the ATLAS software framework Athena [4] and the availability of the.

  2. Monitoring System For Improving Radiation Safety Management

    International Nuclear Information System (INIS)

    Osovizky, A.; Paran, J.; Tal, N.; Ankry, N.; Ashkenazi, B.; Tirosh, D.; Marziano, R.; Chisin, R.

    1999-01-01

    Medi SMARTS (Medical Survey Mapping Automatic Radiation Tracing System), a gamma radiation monitoring system, was installed in a nuclear medicine department. In this paper the evaluation of the system's ability to improve radiation safety management is presented. The system is based on a state of the art software that continuously collects on line radiation measurements for display, analysis and logging. Radiation is measured by GM tubes; the signal is transferred to a data processing unit and then via an RS-485 communication line to a computer. The system automatically identifies the detector type and its calibration factor, thus providing compatibility, maintainability and versatility when changing detectors. Radiation levels are displayed on the nuclear medicine department map at six locations. The system has been operating continuously for more than one year, documenting abnormal events caused by routine operation or failure incidents. In cases where abnormal working conditions were encountered, an alarm message was sent automatically to the supervisor via his tele-pager. An interesting issue observed during the system evaluation, was the inability to distinguish between high radiation levels caused by proper routine operation and those caused by safety failure incidents. The solution included examination of two parameters, radiation levels as well as their duration period. A careful analysis of the historical data, applying the appropriated combined parameters determined for each location, verified that such a system can identify abnormal events, provide alarms to warn in case of incidents and improve standard operating procedures

  3. Automated monitoring of recovered water quality

    Science.gov (United States)

    Misselhorn, J. E.; Hartung, W. H.; Witz, S. W.

    1974-01-01

    Laboratory prototype water quality monitoring system provides automatic system for online monitoring of chemical, physical, and bacteriological properties of recovered water and for signaling malfunction in water recovery system. Monitor incorporates whenever possible commercially available sensors suitably modified.

  4. Automatization of the radiation control measurements

    International Nuclear Information System (INIS)

    Seki, Akio; Ogata, Harumi; Horikoshi, Yoshinori; Shirai, Kenji

    1988-01-01

    Plutonium Fuel Production Facility (PFPF) was constructed to fabricate the MOX fuels for 'MONJU' and 'JOYO' reactors and to develop the practical fuel fabricating technology. For the fuel fabrication process in this facility, centralized controlling system is being adopted for the mass production of the fuel and reduction of the radiation exposure dose. Also, the radiation control systems are suitable for the large-scale facility and the automatic-remote process of the fuel fabrication. One of the typical radiation control systems is the self moving survey system which has been developed by PNC and adopted for the automatic routine monitoring. (author)

  5. Development of automatic laser welding system

    International Nuclear Information System (INIS)

    Ohwaki, Katsura

    2002-01-01

    Laser are a new production tool for high speed and low distortion welding and applications to automatic welding lines are increasing. IHI has long experience of laser processing for the preservation of nuclear power plants, welding of airplane engines and so on. Moreover, YAG laser oscillators and various kinds of hardware have been developed for laser welding and automation. Combining these welding technologies and laser hardware technologies produce the automatic laser welding system. In this paper, the component technologies are described, including combined optics intended to improve welding stability, laser oscillators, monitoring system, seam tracking system and so on. (author)

  6. Automatic read out system for superheated emulsion based neutron detector

    International Nuclear Information System (INIS)

    Meena, J.P.; Parihar, A.; Vaijapurkar, S.G.; Mohan, Anand

    2010-01-01

    Full text: Defence Laboratory, Jodhpur (DLJ) has developed superheated emulsion technology for neutron and gamma measurements. The laboratory has attempted to develop reader system to display neutron dose and dose rate based on acoustic technique. The paper presents a microcontroller based automatic reader system for neutron measurements using indigenously developed superheated emulsion detector. The system is designed for real time counting of bubbles formed in superheated emulsion detector. A piezoelectric transducer is used for sensing bubble acoustic. The front end of system is mainly consisting of specially designed signal conditioning unit consisted of piezoelectric transducer, an amplifier, a high-pass filter, a differentiator, a comparator and monostable multivibrator. The system is based on PIC 18F6520 microcontroller having large internal SRAM, 10-bit internal ADC, I 2 C interface, UART/USART modules. The paper also describes the design of following peripheral units interfaced to microcontroller temperature and battery monitoring, display, keypad and a serial communication. The reader system measures and displays neutron dose and dose rate, number of bubble and elapsed time. The developed system can be used for detecting very low neutron leakage in the accelerators, nuclear reactors and nuclear submarines. The important features of system are compact, light weight, cost effective and high neutron sensitivity. The prototype was tested and evaluated by exposing to 241 Am-Be neutron source and results have been reported

  7. Gamma camera

    International Nuclear Information System (INIS)

    Reiss, K.H.; Kotschak, O.; Conrad, B.

    1976-01-01

    A gamma camera with a simplified setup as compared with the state of engineering is described permitting, apart from good localization, also energy discrimination. Behind the usual vacuum image amplifier a multiwire proportional chamber filled with trifluorine bromium methane is connected in series. Localizing of the signals is achieved by a delay line, energy determination by means of a pulse height discriminator. With the aid of drawings and circuit diagrams, the setup and mode of operation are explained. (ORU) [de

  8. Gamma irradiator

    International Nuclear Information System (INIS)

    Simonet, G.

    1986-09-01

    Fiability of devices set around reactors depends on material resistance under irradiation noticeably joints, insulators, which belongs to composition of technical, safety or physical incasurement devices. The irradiated fuel elements, during their desactivation in a pool, are an interesting gamma irradiation device to simulate damages created in a nuclear environment. The existing facility at Osiris allows to generate an homogeneous rate dose in an important volume. The control of the element distances to irradiation box allows to control this dose rate [fr

  9. Thai Automatic Speech Recognition

    National Research Council Canada - National Science Library

    Suebvisai, Sinaporn; Charoenpornsawat, Paisarn; Black, Alan; Woszczyna, Monika; Schultz, Tanja

    2005-01-01

    .... We focus on the discussion of the rapid deployment of ASR for Thai under limited time and data resources, including rapid data collection issues, acoustic model bootstrap, and automatic generation of pronunciations...

  10. Automatic Payroll Deposit System.

    Science.gov (United States)

    Davidson, D. B.

    1979-01-01

    The Automatic Payroll Deposit System in Yakima, Washington's Public School District No. 7, directly transmits each employee's salary amount for each pay period to a bank or other financial institution. (Author/MLF)

  11. Automatic Test Systems Aquisition

    National Research Council Canada - National Science Library

    1994-01-01

    We are providing this final memorandum report for your information and use. This report discusses the efforts to achieve commonality in standards among the Military Departments as part of the DoD policy for automatic test systems (ATS...

  12. Emergency response exercise of laboratories equipped with gamma spectrometry

    International Nuclear Information System (INIS)

    Mala, H.; Jezkova, T.; Rulik, P.; Beckova, V. et al.

    2014-01-01

    Seven laboratories equipped with semiconductor gamma spectrometry (HPGe detectors) are currently included in the Radiation Monitoring Network (RMN) in the Czech Republic. These laboratories have more than 30 spectrometric chains and approximately 20 'experts' and 70 'users' who would guarantee measurements during the radiological emergency (RE). The emergency exercise was carried out in 5 of them in 2014 (in 4 of them also in 2013). The aim was to test repeatedly their capacity in existing technical facilities and with current staff in the event of a RE and identify problems (bottlenecks) in the whole process from receipt of samples to entering the results into the central database of RMN. Duration of the exercise was 12 hours, due to the shortage of staff; work in one 12-hour shift is presumed during a RE, which the laboratories should be able to provide for 14 days. These exercise samples covered a wide range of commodities that would probably come to the laboratories during the RE (aerosol filters, sorbents for sorption of gaseous forms of iodine, fallout, surface and drinking waters, food chain components and soils). Some of the samples were previously spiked with 85 Sr, 88 Y and 40 K (in the exercise these nuclides represented actual contamination that would occur in RE); liquid samples were spiked with 85 Sr and 88 Y and bulk materials with 40 K.During the exercise almost 800 samples were analysed; in addition, the automatic gamma counter (GA) in Prague laboratory measured other 90 samples automatically during the night (samples were prepared during the day-shift). On the basis of the results the total measuring capacity of the laboratories of RMN CR was estimated at about 1300 samples per day. (authors)

  13. Brand and automaticity

    OpenAIRE

    Liu, J.

    2008-01-01

    A presumption of most consumer research is that consumers endeavor to maximize the utility of their choices and are in complete control of their purchasing and consumption behavior. However, everyday life experience suggests that many of our choices are not all that reasoned or conscious. Indeed, automaticity, one facet of behavior, is indispensable to complete the portrait of consumers. Despite its importance, little attention is paid to how the automatic side of behavior can be captured and...

  14. Position automatic determination technology

    International Nuclear Information System (INIS)

    1985-10-01

    This book tells of method of position determination and characteristic, control method of position determination and point of design, point of sensor choice for position detector, position determination of digital control system, application of clutch break in high frequency position determination, automation technique of position determination, position determination by electromagnetic clutch and break, air cylinder, cam and solenoid, stop position control of automatic guide vehicle, stacker crane and automatic transfer control.

  15. Automatic intelligent cruise control

    OpenAIRE

    Stanton, NA; Young, MS

    2006-01-01

    This paper reports a study on the evaluation of automatic intelligent cruise control (AICC) from a psychological perspective. It was anticipated that AICC would have an effect upon the psychology of driving—namely, make the driver feel like they have less control, reduce the level of trust in the vehicle, make drivers less situationally aware, but might reduce the workload and make driving might less stressful. Drivers were asked to drive in a driving simulator under manual and automatic inte...

  16. Gamma response study of radiation sensitive MOSFETs for their use as gamma radiation sensor

    Energy Technology Data Exchange (ETDEWEB)

    Srivastava, Saurabh; Kumar, A. Vinod [Radiation Safety Systems Division, Bhabha Atomic Research Centre, Mumbai (India); Aggarwal, Bharti; Singh, Arvind; Topkar, Anita, E-mail: anita@barc.gov.in [Electronics Division, Bhabha Atomic Research Centre, Mumbai (India)

    2016-05-23

    Continuous monitoring of gamma dose is important in various fields like radiation therapy, space-related research, nuclear energy programs and high energy physics experiment facilities. The present work is focused on utilization of radiation-sensitive Metal-Oxide-Semiconductor Field Effect Transistors (MOSFETs) to monitor gamma radiation doses. Static characterization of these detectors was performed to check their expected current-voltage relationship. Threshold voltage and transconductance per unit gate to source voltage (K factor) were calculated from the experimental data. The detector was exposed to gamma radiation in both, with and without gate bias voltage conditions, and change in threshold voltage was monitored at different gamma doses. The experimental data was fitted to obtain equation for dependence of threshold voltage on gamma dose. More than ten times increase in sensitivity was observed in biased condition (+3 V) compared to the unbiased case.

  17. Calibration procedures of area monitors in terms of the Ambient Dose Equivalent H*(10), for gamma, x-ray radiation fields

    International Nuclear Information System (INIS)

    Dieguez Davila, L.E.

    1998-01-01

    In the present thesis procedures for calibrating portable survey meters in terms of the new ICRU quantities H*(10) ambient dose equivalent are discussed. Also the remendations of International Comission on Radiation Protection in their report ICRP 60 that inludes the operational magnitudes that the International Comission of Radiation Units proposed for calibrating area monitors

  18. Automatic classification of gammas-gamma coincidence matrices; Clasificacion automatizada de matrices de coincidencias Gamma-Gamma

    Energy Technology Data Exchange (ETDEWEB)

    Los Arcos Merino, J M; Gonzalez, J A

    1978-07-01

    The information obtained during a coincidence experiment, recorded on magnetic tape by a MULTI-8 minicomputer, is transferred to a new tape in 36 bit words, using the program LEC0M8. The classification in two dimensional matrix form is carried out off-line, on a magnetic disk file, by the program CLAFI. On finishing classification one obtains a copy of the coincidence matrix on the second magnetic tape. Both programs are written to be processed in that order with the UNIVAC 1106 computer of J.E.N. (Author) 4 refs.

  19. Gamma ray bursts observed with WATCH‐EURECA

    DEFF Research Database (Denmark)

    Brandt, Søren; Lund, Niels; Castro-Tirado, A. J.

    1994-01-01

    The WATCH wide field x‐ray monitor has the capability of independently locating bright Gamma Ray Bursts to 1° accuracy. We report the preliminary positions of 12 Gamma Ray Bursts observed with the WATCH monitor flown on the ES spacecraft EURECA during its 11 month mission. Also the recurrence...

  20. Application of radcal gamma thermometer assemblies for core coolant monitoring in ASEA ATOM reactors with particular reference to the Barsebaeck plants

    International Nuclear Information System (INIS)

    Romslo, K.

    1982-02-01

    In this study reference designs for instrument assemblies containing RGT rods to monitor the core coolant conditions in the Barsebaeck reactors have been worked out. Four such strings would be required to satisfy the Reg. Guide 1.97 reqiurements. The signal transmission to the control room and the presentation of information to the operators have been addressed. Downcomer water level measurement is considered important in order to get an early warning about leakages. Possible ways of diversifying the existing measurement method using RGTs are mentioned, and the design of a downcomer RGT rod has been suggested. To fully comply with Reg. Guide 1.97, water level measurements above core would be required. In a conceptual way it has been shown how an RGT rod could be extended up into this region, if so required. The possibility of making an ideal core coolant monitoring system by replacing one of the structural rods (water rods) in the fuel bundle by an RGT rod is pointed out. There are foreseen, however, several practical obstacles in pursuing the idea. The present state of RGT development and further work required to get the intrument licensed as a coolant monitoring device, has been defined. (Author)