WorldWideScience

Sample records for automatic control

  1. Automatic Camera Control

    DEFF Research Database (Denmark)

    Burelli, Paolo; Preuss, Mike

    2014-01-01

    Automatically generating computer animations is a challenging and complex problem with applications in games and film production. In this paper, we investigate howto translate a shot list for a virtual scene into a series of virtual camera configurations — i.e automatically controlling the virtual...... camera. We approach this problem by modelling it as a dynamic multi-objective optimisation problem and show how this metaphor allows a much richer expressiveness than a classical single objective approach. Finally, we showcase the application of a multi-objective evolutionary algorithm to generate a shot...

  2. Mnesors for automatic control

    OpenAIRE

    Champenois, Gilles

    2009-01-01

    Mnesors are defined as elements of a semimodule over the min-plus integers. This two-sorted structure is able to merge graduation properties of vectors and idempotent properties of boolean numbers, which makes it appropriate for hybrid systems. We apply it to the control of an inverted pendulum and design a full logical controller, that is, without the usual algebra of real numbers.

  3. Automatic Control of Water Pumping Stations

    Institute of Scientific and Technical Information of China (English)

    Muhannad Alrheeh; JIANG Zhengfeng

    2006-01-01

    Automatic Control of pumps is an interesting proposal to operate water pumping stations among many kinds of water pumping stations according to their functions.In this paper, our pumping station is being used for water supply system. This paper is to introduce the idea of pump controller and the important factors that must be considering when we want to design automatic control system of water pumping stations. Then the automatic control circuit with the function of all components will be introduced.

  4. Automatic control of nuclear power plants

    International Nuclear Information System (INIS)

    The fundamental concepts in automatic control are surveyed, and the purpose of the automatic control of pressurized water reactors is given. The response characteristics for the main components are then studied and block diagrams are given for the main control loops (turbine, steam generator, and nuclear reactors)

  5. Integrated Coordinated Optimization Control of Automatic Generation Control and Automatic Voltage Control in Regional Power Grids

    OpenAIRE

    Qiu-Yu Lu; Wei Hu; Le Zheng; Yong Min; Miao Li; Xiao-Ping Li; Wei-Chun Ge; Zhi-Ming Wang

    2012-01-01

    Automatic Generation Control (AGC) and Automatic Voltage Control (AVC) are key approaches to frequency and voltage regulation in power systems. However, based on the assumption of decoupling of active and reactive power control, the existing AGC and AVC systems work independently without any coordination. In this paper, a concept and method of hybrid control is introduced to set up an Integrated Coordinated Optimization Control (ICOC) system for AGC and AVC. Concerning the diversity of contro...

  6. Automatic Control of Freeboard and Turbine Operation

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter; Frigaard, Peter Bak; Friis-Madsen, Erik;

    The report deals with the modules for automatic control of freeboard and turbine operation on board the Wave dragon, Nissum Bredning (WD-NB) prototype, and covers what has been going on up to ultimo 2003.......The report deals with the modules for automatic control of freeboard and turbine operation on board the Wave dragon, Nissum Bredning (WD-NB) prototype, and covers what has been going on up to ultimo 2003....

  7. Automatic Synthesis of Robust and Optimal Controllers

    DEFF Research Database (Denmark)

    Cassez, Franck; Jessen, Jan Jacob; Larsen, Kim Guldstrand;

    2009-01-01

    In this paper, we show how to apply recent tools for the automatic synthesis of robust and near-optimal controllers for a real industrial case study. We show how to use three different classes of models and their supporting existing tools, Uppaal-TiGA for synthesis, phaver for verification, and S...

  8. Integrated Coordinated Optimization Control of Automatic Generation Control and Automatic Voltage Control in Regional Power Grids

    Directory of Open Access Journals (Sweden)

    Qiu-Yu Lu

    2012-09-01

    Full Text Available Automatic Generation Control (AGC and Automatic Voltage Control (AVC are key approaches to frequency and voltage regulation in power systems. However, based on the assumption of decoupling of active and reactive power control, the existing AGC and AVC systems work independently without any coordination. In this paper, a concept and method of hybrid control is introduced to set up an Integrated Coordinated Optimization Control (ICOC system for AGC and AVC. Concerning the diversity of control devices and the characteristics of discrete control interaction with a continuously operating power system, the ICOC system is designed in a hierarchical structure and driven by security, quality and economic events, consequently reducing optimization complexity and realizing multi-target quasi-optimization. In addition, an innovative model of Loss Minimization Control (LMC taking into consideration active and reactive power regulation is proposed to achieve a substantial reduction in network losses and a cross iterative method for AGC and AVC instructions is also presented to decrease negative interference between control systems. The ICOC system has already been put into practice in some provincial regional power grids in China. Open-looping operation tests have proved the validity of the presented control strategies.

  9. 11th Portuguese Conference on Automatic Control

    CERN Document Server

    Matos, Aníbal; Veiga, Germano

    2015-01-01

    During the last 20 years the Portuguese association of automatic control, Associação Portuguesa de Controlo Automático, with the sponsorship of IFAC have established the CONTROLO conference as a reference international forum where an effective exchange of knowledge and experience amongst researchers active in various theoretical and applied areas of systems and control can take place, always including considerable space for promoting new technical applications and developments, real-world challenges and success stories. In this 11th edition the CONTROLO conference evolved by introducing two strategic partnerships with Spanish and Brazilian associations in automatic control, Comité Español de Automática and Sociedade Brasileira de Automatica, respectively.

  10. Automatic Flatness Control of Cold Rolling Mill

    Science.gov (United States)

    Anbe, Yoshiharu; Sekiguchi, Kunio

    One of the subjects of cold rolling is a flatness of the rolled strip. Conventionally, measured strip flatness was approximated by polynomial (2th, 4th, 6th) equation across the entire strip width. This made it difficult to deal with desired loose edge or any desired flatness across the entire strip width. Also conventional flatness control was done for the entire strip width, so if there is a different flatness error among drive side and work side, conventional flatness control can not control properly. We propose independent strip flatness control among drive side and work side, and also automatic flatness control (AFC) system with arbitrary desired strip flatness. Also some applied results to cold mill are shown.

  11. Automatic Control of Configuration of Web Anonymization

    Directory of Open Access Journals (Sweden)

    Tomas Sochor

    2013-01-01

    Full Text Available Anonymization of the Internet traffic usually hides details about the request originator from the target server. Such a disguise might be required in some situations, especially in the case of web browsing. Although the web traffic anonymization is not a part of the http specification, it could be achieved using a certain extra tool. Significant deceleration of anonymized traffic compared to normal traffic is inevitable but it can be controlled in some cases as this article suggests. The results presented here focus on measuring the parameters of such deceleration in terms of response time, transmission speed and latency and proposing the way how to control it. This study focuses on TOR primarily because recent studies have concluded that other tools (like I2P and JAP provide worse service. Sets of 14 file locations and 30 web pages have been formed and the latency, response time and transmission speed during the page or file download were measured repeatedly both with TOR active in various configurations and without TOR. The main result presented here comprises several ways how to improve the TOR anonymization efficiency and the proposal for its automatic control. In spite of the fact that efficiency still remains too low compared to normal web traffic for ordinary use, its automatic control could make TOR a useful tool in special cases.

  12. Automatic Control of ITER-like Structures

    Energy Technology Data Exchange (ETDEWEB)

    Bosia, G.; Bremond, S

    2005-07-01

    In ITER Ion Cyclotron System requires a power transfer efficiency in excess of 90% from power source to plasma in quasi continuous operation. This implies the availability of a control system capable of optimizing the array radiation spectrum, automatically acquiring impedance match between the power source and the plasma loaded array at the beginning of the power pulse and maintaining it against load variations due to plasma position and plasma edge parameters fluctuations, rapidly detecting voltage breakdowns in the array and/or in the transmission system and reliably discriminating them from fast load variations. In this paper a proposal for a practical ITER control system, including power, phase, frequency and impedance matching is described. (authors)

  13. 2nd International Conference on Mechatronics and Automatic Control

    CERN Document Server

    2015-01-01

    This book examines mechatronics and automatic control systems. The book covers important emerging topics in signal processing, control theory, sensors, mechanic manufacturing systems and automation. The book presents papers from the second International Conference on Mechatronics and Automatic Control Systems held in Beijing, China on September 20-21, 2014. Examines how to improve productivity through the latest advanced technologies Covering new systems and techniques in the broad field of mechatronics and automatic control systems.

  14. An electronically controlled automatic security access gate

    Directory of Open Access Journals (Sweden)

    Jonathan A. ENOKELA

    2014-11-01

    Full Text Available The security challenges being encountered in many places require electronic means of controlling access to communities, recreational centres, offices, and homes. The electronically controlled automated security access gate being proposed in this work helps to prevent an unwanted access to controlled environments. This is achieved mainly through the use of a Radio Frequency (RF transmitter-receiver pair. In the design a microcontroller is programmed to decode a given sequence of keys that is entered on a keypad and commands a transmitter module to send out this code as signal at a given radio frequency. Upon reception of this RF signal by the receiver module, another microcontroller activates a driver circuitry to operate the gate automatically. The codes for the microcontrollers were written in C language and were debugged and compiled using the KEIL Micro vision 4 integrated development environment. The resultant Hex files were programmed into the memories of the microcontrollers with the aid of a universal programmer. Software simulation was carried out using the Proteus Virtual System Modeling (VSM version 7.7. A scaled-down prototype of the system was built and tested. The electronically controlled automated security access gate can be useful in providing security for homes, organizations, and automobile terminals. The four-character password required to operate the gate gives the system an increased level of security. Due to its standalone nature of operation the system is cheaper to maintain in comparison with a manually operated type.

  15. 2013 International Conference on Mechatronics and Automatic Control Systems

    CERN Document Server

    2014-01-01

    This book examines mechatronics and automatic control systems. The book covers important emerging topics in signal processing, control theory, sensors, mechanic manufacturing systems and automation. The book presents papers from the 2013 International Conference on Mechatronics and Automatic Control Systems held in Hangzhou, China on August 10-11, 2013. .

  16. Automatic presser-foot force control for industrial sewing machines

    OpenAIRE

    Carvalho, Helder; Silva, Luís F.; A. M. Rocha; Monteiro, João L.

    2012-01-01

    To develop and test control methods for real-time automatic presser-foot force control in industrial sewing machines. In this work, a closed-loop controller that controls presser-foot maximum vertical displacement is presented and compared to existing solutions that adjust force depending on sewing speed. Automatic force control can reduce problems such as stitch irregularity, stitch distortions and material damage, besides making material handling easier. Design/methodology/approach ...

  17. A method of automatic control procedures cardiopulmonary resuscitation

    Science.gov (United States)

    Bureev, A. Sh.; Zhdanov, D. S.; Kiseleva, E. Yu.; Kutsov, M. S.; Trifonov, A. Yu.

    2015-11-01

    The study is to present the results of works on creation of methods of automatic control procedures of cardiopulmonary resuscitation (CPR). A method of automatic control procedure of CPR by evaluating the acoustic data of the dynamics of blood flow in the bifurcation of carotid arteries and the dynamics of air flow in a trachea according to the current guidelines for CPR is presented. Evaluation of the patient is carried out by analyzing the respiratory noise and blood flow in the interspaces between the chest compressions and artificial pulmonary ventilation. The device operation algorithm of automatic control procedures of CPR and its block diagram has been developed.

  18. Automatic reference level control for an antenna pattern recording system

    Science.gov (United States)

    Lipin, R., Jr.

    1971-01-01

    Automatic gain control system keeps recorder reference levels within 0.2 decibels during operation. System reduces recorder drift during antenna radiation distribution determinations over an eight hour period.

  19. Intelligent control schemes applied to Automatic Generation Control

    Directory of Open Access Journals (Sweden)

    Dingguo Chen

    2016-04-01

    Full Text Available Integrating ever increasing amount of renewable generating resources to interconnected power systems has created new challenges to the safety and reliability of today‟s power grids and posed new questions to be answered in the power system modeling, analysis and control. Automatic Generation Control (AGC must be extended to be able to accommodate the control of renewable generating assets. In addition, AGC is mandated to operate in accordance with the NERC‟s Control Performance Standard (CPS criteria, which represent a greater flexibility in relaxing the control of generating resources and yet assuring the stability and reliability of interconnected power systems when each balancing authority operates in full compliance. Enhancements in several aspects to the traditional AGC must be made in order to meet the aforementioned challenges. It is the intention of this paper to provide a systematic, mathematical formulation for AGC as a first attempt in the context of meeting the NERC CPS requirements and integrating renewable generating assets, which has not been seen reported in the literature to the best knowledge of the authors. Furthermore, this paper proposes neural network based predictive control schemes for AGC. The proposed controller is capable of handling complicated nonlinear dynamics in comparison with the conventional Proportional Integral (PI controller which is typically most effective to handle linear dynamics. The neural controller is designed in such a way that it has the capability of controlling the system generation in the relaxed manner so the ACE is controlled to a desired range instead of driving it to zero which would otherwise increase the control effort and cost; and most importantly the resulting system control performance meets the NERC CPS requirements and/or the NERC Balancing Authority’s ACE Limit (BAAL compliance requirements whichever are applicable.

  20. Towards Automatic Decentralized Control Structure Selection

    DEFF Research Database (Denmark)

    Jørgensen, John Bagterp; Jørgensen, Sten Bay

    2000-01-01

    A subtask in integration of design and control of chemical processes is the selection of a control structure. Automating the selection of the control structure enables sequential integration of process and control design. As soon as the process is specified or computed, a structure for decentrali......A subtask in integration of design and control of chemical processes is the selection of a control structure. Automating the selection of the control structure enables sequential integration of process and control design. As soon as the process is specified or computed, a structure...... of model formulation and mathematical programming. (C) 2000 Elsevier Science Ltd. All rights reserved....

  1. Automatic power control for a pressurized water reactor

    International Nuclear Information System (INIS)

    During a normal operation of a pressurized water reactor (PWR), the reactivity is controlled by control rods, boron, and the average temperature of the primary coolant. Especially in load follow operation, the reactivity change is induced by changes in power level and effects of xenon concentration. The control of the core power distribution is concerned, mainly, with the axial power distribution which depends on insertion and withdrawal of the control rods resulting in additional reactivity compensation. The utilization of part strength control element assemblies (PSCEAs) is quite appropriate for a control of the power distribution in the case of Yonggwang Nuclear Unit 3 (YGN Unit 3). However, control of the PSCEAs is not automatic, and changes in the boron concentration by dilution/boration are done manually. Thus, manual control of the PSCEAs and the boron concentration require the operator's experience and knowledge for a successful load follow operation. In this thesis, the new concepts have been proposed to adapt for an automatic power control in a PWR. One of the new concepts is the mode K control, another is a fuzzy power control. The system in mode K control implements a heavy-worth bank dedicated to axial shape control, independent of the existing regulating banks. The heavy bank provides a monotonic relationship between its motion and the axial power shape change, which allows automatic control of the axial power distribution. And the mode K enables precise regulation, by using double closed-loop control of the reactor coolant temperature and the axial power difference. Automatic reactor power control permits the nuclear power plant to accommodate the load follow operations, including frequency control, to respond to the grid requirements. The mode K reactor control concepts were tested using simulation responses of a Korean standardized 1000-MWe PWR which is a reference plant for the YGN Unit 3. The simulation results illustrate that the mode K would be

  2. Evolutionary game dynamics of controlled and automatic decision-making

    Science.gov (United States)

    Toupo, Danielle F. P.; Strogatz, Steven H.; Cohen, Jonathan D.; Rand, David G.

    2015-07-01

    We integrate dual-process theories of human cognition with evolutionary game theory to study the evolution of automatic and controlled decision-making processes. We introduce a model in which agents who make decisions using either automatic or controlled processing compete with each other for survival. Agents using automatic processing act quickly and so are more likely to acquire resources, but agents using controlled processing are better planners and so make more effective use of the resources they have. Using the replicator equation, we characterize the conditions under which automatic or controlled agents dominate, when coexistence is possible and when bistability occurs. We then extend the replicator equation to consider feedback between the state of the population and the environment. Under conditions in which having a greater proportion of controlled agents either enriches the environment or enhances the competitive advantage of automatic agents, we find that limit cycles can occur, leading to persistent oscillations in the population dynamics. Critically, however, these limit cycles only emerge when feedback occurs on a sufficiently long time scale. Our results shed light on the connection between evolution and human cognition and suggest necessary conditions for the rise and fall of rationality.

  3. Towards Automatic Decentralized Control Structure Selection

    DEFF Research Database (Denmark)

    A subtask in integration of design and control of chemical processes is the selection of a control structure. Automating the selection of the control structure enables sequential integration of process and controld esign. As soon as the process is specified or computed, a structure for decentrali......A subtask in integration of design and control of chemical processes is the selection of a control structure. Automating the selection of the control structure enables sequential integration of process and controld esign. As soon as the process is specified or computed, a structure...... of model formulation and mathematical programming....

  4. Automatic control system design of laser interferometer

    Science.gov (United States)

    Lu, Qingjie; Li, Chunjie; Sun, Hao; Ren, Shaohua; Han, Sen

    2015-10-01

    There are a lot of shortcomings with traditional optical adjustment in interferometry, such as low accuracy, time-consuming, labor-intensive, uncontrollability, and bad repetitiveness, so we treat the problem by using wireless remote control system. Comparing to the traditional method, the effect of vibration and air turbulence will be avoided. In addition the system has some peculiarities of low cost, high reliability and easy operation etc. Furthermore, the switching between two charge coupled devices (CCDs) can be easily achieved with this wireless remote control system, which is used to collect different images. The wireless transmission is achieved by using Radio Frequency (RF) module and programming the controller, pulse width modulation (PWM) of direct current (DC) motor, real-time switching of relay and high-accuracy displacement control of FAULHABER motor are available. The results of verification test show that the control system has good stability with less than 5% packet loss rate, high control accuracy and millisecond response speed.

  5. An electronically controlled automatic security access gate

    OpenAIRE

    Jonathan A. Enokela; Michael N. TYOWUAH

    2014-01-01

    The security challenges being encountered in many places require electronic means of controlling access to communities, recreational centres, offices, and homes. The electronically controlled automated security access gate being proposed in this work helps to prevent an unwanted access to controlled environments. This is achieved mainly through the use of a Radio Frequency (RF) transmitter-receiver pair. In the design a microcontroller is programmed to decode a given sequence of keys that is ...

  6. 5th International Conference on Electrical Engineering and Automatic Control

    CERN Document Server

    Yao, Yufeng

    2016-01-01

    On the basis of instrument electrical and automatic control system, the 5th International Conference on Electrical Engineering and Automatic Control (CEEAC) was established at the crossroads of information technology and control technology, and seeks to effectively apply information technology to a sweeping trend that views control as the core of intelligent manufacturing and life. This book takes a look forward into advanced manufacturing development, an area shaped by intelligent manufacturing. It highlights the application and promotion of process control represented by traditional industries, such as the steel industry and petrochemical industry; the technical equipment and system cooperative control represented by robot technology and multi-axis CNC; and the control and support of emerging process technologies represented by laser melting and stacking, as well as the emerging industry represented by sustainable and intelligent life. The book places particular emphasis on the micro-segments field, such as...

  7. Automatic polarization control in optical sampling system

    Science.gov (United States)

    Zhao, Zhao; Yang, Aiying; Feng, Lihui

    2015-08-01

    In an optical sampling system for high-speed optical communications, polarization controlling is one of the most important parts of the system, regardless of nonlinear optical sampling or linear optical sampling. A simple method based on variance calculation of sampled data is proposed in this paper to tune the wave plates in a motor-driven polarization controller. In the experiment, an optical sampling system base on SFG in PPLN is carried for a 10Gbit/s or beyond optical data signal. The results demonstrate that, with the proposed method, the error of estimated Q factor from the sampled data is least, and the tuning time of optimized polarization state is less than 30 seconds with the accuracy of +/-1°.

  8. Nonlinear model predictive control using automatic differentiation

    OpenAIRE

    Al Seyab, Rihab Khalid Shakir

    2006-01-01

    Although nonlinear model predictive control (NMPC) might be the best choice for a nonlinear plant, it is still not widely used. This is mainly due to the computational burden associated with solving online a set of nonlinear differential equations and a nonlinear dynamic optimization problem in real time. This thesis is concerned with strategies aimed at reducing the computational burden involved in different stages of the NMPC such as optimization problem, state estimation, an...

  9. Simulation of the TREAT-Upgrade Automatic Reactor Control System

    International Nuclear Information System (INIS)

    This paper describes the design of the Automatic Reactor Control System (ARCS) for the Transient Reactor Test Facility (TREAT) Upgrade. A simulation was used to facilitate the ARCS design and to completely test and verify its operation before installation at the TREAT facility

  10. Automatic Tuning of the Superheat Controller in a Refrigeration Plant

    DEFF Research Database (Denmark)

    Rasmussen, Henrik; Thybo, Claus; Larsen, Lars F. S.

    2006-01-01

    This paper proposes an automatic tuning of the superheat control in a refrigeration system using a relay method. By means of a simple evaporator model that captures the important dynamics and non-linearities of the superheat a gain-scheduling that compensates for the variation of the process gain...

  11. Controlled versus Automatic Processes: Which Is Dominant to Safety? The Moderating Effect of Inhibitory Control

    OpenAIRE

    Yaoshan Xu; Yongjuan Li; Weidong Ding; Fan Lu

    2014-01-01

    This study explores the precursors of employees' safety behaviors based on a dual-process model, which suggests that human behaviors are determined by both controlled and automatic cognitive processes. Employees' responses to a self-reported survey on safety attitudes capture their controlled cognitive process, while the automatic association concerning safety measured by an Implicit Association Test (IAT) reflects employees' automatic cognitive processes about safety. In addition, this study...

  12. Declarative camera control for automatic cinematography

    Energy Technology Data Exchange (ETDEWEB)

    Christianson, D.B.; Anderson, S.E.; Li-wei He [Univ. of Washington, Seattle, WA (United States)] [and others

    1996-12-31

    Animations generated by interactive 3D computer graphics applications are typically portrayed either from a particular character`s point of view or from a small set of strategically-placed viewpoints. By ignoring camera placement, such applications fail to realize important storytelling capabilities that have been explored by cinematographers for many years. In this paper, we describe several of the principles of cinematography and show how they can be formalized into a declarative language, called the Declarative Camera Control Language (DCCL). We describe the application of DCCL within the context of a simple interactive video game and argue that DCCL represents cinematic knowledge at the same level of abstraction as expert directors by encoding 16 idioms from a film textbook. These idioms produce compelling animations, as demonstrated on the accompanying videotape.

  13. Randomized algorithms in automatic control and data mining

    CERN Document Server

    Granichin, Oleg; Toledano-Kitai, Dvora

    2015-01-01

    In the fields of data mining and control, the huge amount of unstructured data and the presence of uncertainty in system descriptions have always been critical issues. The book Randomized Algorithms in Automatic Control and Data Mining introduces the readers to the fundamentals of randomized algorithm applications in data mining (especially clustering) and in automatic control synthesis. The methods proposed in this book guarantee that the computational complexity of classical algorithms and the conservativeness of standard robust control techniques will be reduced. It is shown that when a problem requires "brute force" in selecting among options, algorithms based on random selection of alternatives offer good results with certain probability for a restricted time and significantly reduce the volume of operations.

  14. Facilitator control as automatic behavior: A verbal behavior analysis

    OpenAIRE

    Hall, Genae A.

    1993-01-01

    Several studies of facilitated communication have demonstrated that the facilitators were controlling and directing the typing, although they appeared to be unaware of doing so. Such results shift the focus of analysis to the facilitator's behavior and raise questions regarding the controlling variables for that behavior. This paper analyzes facilitator behavior as an instance of automatic verbal behavior, from the perspective of Skinner's (1957) book Verbal Behavior. Verbal behavior is autom...

  15. Automatic control of paint spray booth with integrated dryer

    OpenAIRE

    Živec, Marko

    2016-01-01

    The thesis presents a solution for automatic control of a paint spray booth with integrated dryer. The conditions in the booth must be as constant as possible to assure better quality of surface coating applied on a particular object, while also lowering the consumption of energy sources and improving the working environment. The thesis includes descriptions of physical elements used for control and regulation, the software solution, which includes algorithms for the regulation of the tempera...

  16. 2011 International Conference in Electrics, Communication and Automatic Control Proceedings

    CERN Document Server

    2012-01-01

    This two-volume set contains the very latest, cutting-edge material in electrics, communication and automatic control. As a vital field of research that is highly relevant to current developments in a number of technological domains, the subjects it covers include micro-electronics and integrated circuit control, signal processing technology, next-generation network infrastructure, wireless communication and scientific instruments. The aim of the International Conference in Electrics, Communication and Automatic Control, held in Chongqing, China, in June 2011 was to provide a valuable inclusive platform for researchers, engineers, academicians and industrial professionals from all over the world to share their research results with fellow scientists in the sector. The call for papers netted well over 600 submissions, of which 224 were selected for presentation. This fully peer-reviewed collection of papers from the conference can be viewed as a single-source compendium of the latest trends and techniques in t...

  17. Controlled versus automatic processes: which is dominant to safety? The moderating effect of inhibitory control.

    Science.gov (United States)

    Xu, Yaoshan; Li, Yongjuan; Ding, Weidong; Lu, Fan

    2014-01-01

    This study explores the precursors of employees' safety behaviors based on a dual-process model, which suggests that human behaviors are determined by both controlled and automatic cognitive processes. Employees' responses to a self-reported survey on safety attitudes capture their controlled cognitive process, while the automatic association concerning safety measured by an Implicit Association Test (IAT) reflects employees' automatic cognitive processes about safety. In addition, this study investigates the moderating effects of inhibition on the relationship between self-reported safety attitude and safety behavior, and that between automatic associations towards safety and safety behavior. The results suggest significant main effects of self-reported safety attitude and automatic association on safety behaviors. Further, the interaction between self-reported safety attitude and inhibition and that between automatic association and inhibition each predict unique variances in safety behavior. Specifically, the safety behaviors of employees with lower level of inhibitory control are influenced more by automatic association, whereas those of employees with higher level of inhibitory control are guided more by self-reported safety attitudes. These results suggest that safety behavior is the joint outcome of both controlled and automatic cognitive processes, and the relative importance of these cognitive processes depends on employees' individual differences in inhibitory control. The implications of these findings for theoretical and practical issues are discussed at the end.

  18. Controlled versus automatic processes: which is dominant to safety? The moderating effect of inhibitory control.

    Directory of Open Access Journals (Sweden)

    Yaoshan Xu

    Full Text Available This study explores the precursors of employees' safety behaviors based on a dual-process model, which suggests that human behaviors are determined by both controlled and automatic cognitive processes. Employees' responses to a self-reported survey on safety attitudes capture their controlled cognitive process, while the automatic association concerning safety measured by an Implicit Association Test (IAT reflects employees' automatic cognitive processes about safety. In addition, this study investigates the moderating effects of inhibition on the relationship between self-reported safety attitude and safety behavior, and that between automatic associations towards safety and safety behavior. The results suggest significant main effects of self-reported safety attitude and automatic association on safety behaviors. Further, the interaction between self-reported safety attitude and inhibition and that between automatic association and inhibition each predict unique variances in safety behavior. Specifically, the safety behaviors of employees with lower level of inhibitory control are influenced more by automatic association, whereas those of employees with higher level of inhibitory control are guided more by self-reported safety attitudes. These results suggest that safety behavior is the joint outcome of both controlled and automatic cognitive processes, and the relative importance of these cognitive processes depends on employees' individual differences in inhibitory control. The implications of these findings for theoretical and practical issues are discussed at the end.

  19. Evaluation of automatic face recognition for automatic border control on actual data recorded of travellers at Schiphol Airport

    NARCIS (Netherlands)

    Spreeuwers, L.J.; Hendrikse, A.J.; Gerritsen, K.J.; Brömme, A.; Busch, C.

    2012-01-01

    Automatic border control at airports using automated facial recognition for checking the passport is becoming more and more common. A problem is that it is not clear how reliable these automatic gates are. Very few independent studies exist that assess the reliability of automated facial recognition

  20. Tracking control mechanisms for positioning automatic CRD exchanger

    International Nuclear Information System (INIS)

    Purpose: To enable completely automatic positioning for the automatic CRD (control rod drives) exchanger, as well as shorten the time for the exchanging operation and save the operator's labour. Constitution: Images of a target attached to the lower flange face of CRD are picked up by a fiber scope mounted to a mounting head. The images are converted through I.T.V. into electrical signals, passed through a cable and then sent to a pattern recognition mechanism. The position for the images of the target is calculated and the calculated position is sent to a drive control section, where the position for the images of the target is compared with a reference position for the images (exactly aligned position) and the moving amount of the mounting head is calculated to move the driving section and thereby complete the positioning. (Kawakami, Y.)

  1. Automatic vehicle parking using an evolution-obtained neural controller

    OpenAIRE

    Ronchetti, Franco; Lanzarini, Laura Cristina

    2011-01-01

    Within the problems that can be solved with autonomous robots, automatic parking is an area of great interest, since it presents a complex scenario where the agent must go through a series of obstacles to reach its goal. Existing solutions usually require some kind of external mark for monitoring or global vision that indicates where the agent is at a given time. This article presents an evolutionary strategy to generate a robotic controller based on a neural network that successfully solves ...

  2. Research on Fuzzy Control for Automatic Transmission of Tracked Vehicles

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    A principle of fuzzy control for tracked vehicles is proposed to make its automatic transmission system be able to adapt complex running conditions, and a model of its power train is established to be used in simulation. Based on the fuzzy control method, a fuzzy shift control system composed of a basic shift strategy and a fuzzy modification module is developed to improve the dynamic characteristics and cross-country maneuverability. Simulation results show that the fuzzy shift strategy can improve the shift quality under manifold driving conditions and avoid cycled shift effectively. Therefore,the proposed fuzzy shift strategies are proved to be feasible and practicable.

  3. From the Conception to the Marketing of a New Automatic Control

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Kildegaard, Erik; Boel, Jan

    1985-01-01

    From a historical viewpoint, product technology has developed via radiator thermostats, return thermostats and selfacting automatic temperature and pressure controls towards more integrated automatic control systems also including weather compensators, which offer benefits in the form of energy...

  4. Adaptive neuro-fuzzy inference system based automatic generation control

    Energy Technology Data Exchange (ETDEWEB)

    Hosseini, S.H.; Etemadi, A.H. [Department of Electrical Engineering, Sharif University of Technology, Tehran (Iran)

    2008-07-15

    Fixed gain controllers for automatic generation control are designed at nominal operating conditions and fail to provide best control performance over a wide range of operating conditions. So, to keep system performance near its optimum, it is desirable to track the operating conditions and use updated parameters to compute control gains. A control scheme based on artificial neuro-fuzzy inference system (ANFIS), which is trained by the results of off-line studies obtained using particle swarm optimization, is proposed in this paper to optimize and update control gains in real-time according to load variations. Also, frequency relaxation is implemented using ANFIS. The efficiency of the proposed method is demonstrated via simulations. Compliance of the proposed method with NERC control performance standard is verified. (author)

  5. Development of advanced automatic control system for nuclear ship. 2. Perfect automatic operation after reactor scram events

    Energy Technology Data Exchange (ETDEWEB)

    Yabuuchi, Noriaki; Nakazawa, Toshio; Takahashi, Hiroki; Shimazaki, Junya; Hoshi, Tsutao [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-11-01

    An automatic operation system has been developed for the purpose of realizing a perfect automatic plant operation after reactor scram events. The goal of the automatic operation after a reactor scram event is to bring the reactor hot stand-by condition automatically. The basic functions of this system are as follows; to monitor actions of the equipments of safety actions after a reactor scram, to control necessary control equipments to bring a reactor to a hot stand-by condition automatically, and to energize a decay heat removal system. The performance evaluation on this system was carried out by comparing the results using to Nuclear Ship Engineering Simulation System (NESSY) and the those measured in the scram test of the nuclear ship `Mutsu`. As the result, it was showed that this system had the sufficient performance to bring a reactor to a hot syand-by condition quickly and safety. (author)

  6. Review on development progress of automatic manual transmissions control

    Institute of Scientific and Technical Information of China (English)

    ALI Amir Ibrahim; QIN Da-tong; ATTIA Nabil Abdulla

    2004-01-01

    In recent years, the sustainable development of automatic manual transmissions (AMTs) control in vehicles is conspicuous. The control applications have grown fast and steadily due to the tremendous progress in power electronics components and the control software that enhance the requirements for delivering higher vehicles performance. AMTs control strategies achieve a reduction in the driveline dynamic oscillations behavior during gear shifting and clutch starting up processes.AMTs future expectations are an increase of torque capacity, more speed ratios and the development of advanced and efficient electronic control systems. This paper concerns with the progressing view of AMTs in the past, today and future, gives an overview of the potential dynamic problems concerned with AMTs and some control strategies used to solve those problems.

  7. Automatic control system generation for robot design validation

    Science.gov (United States)

    Bacon, James A. (Inventor); English, James D. (Inventor)

    2012-01-01

    The specification and drawings present a new method, system and software product for and apparatus for generating a robotic validation system for a robot design. The robotic validation system for the robot design of a robotic system is automatically generated by converting a robot design into a generic robotic description using a predetermined format, then generating a control system from the generic robotic description and finally updating robot design parameters of the robotic system with an analysis tool using both the generic robot description and the control system.

  8. Robust Fallback Scheme for the Danish Automatic Voltage Control System

    DEFF Research Database (Denmark)

    Qin, Nan; Dmitrova, Evgenia; Lund, Torsten;

    2015-01-01

    This paper proposes a fallback scheme for the Danish automatic voltage control system. It will be activated in case of the local station loses telecommunication to the control center and/or the local station voltage violates the acceptable operational limits. It cuts in/out switchable and tap......-able shunts to maintain the voltage locally. The fallback scheme is fully selfregulated according to the predefined triggering logic. In order to keep the robustness and avoid many shunts are being triggered in a short term, the inverse time characteristic is used to trigger switching one by one. This scheme...

  9. Automatic Reactive Power Control Using FC-TCR

    Directory of Open Access Journals (Sweden)

    Dhruvang R Gayakwad

    2014-06-01

    Full Text Available A fixed capacitor-thyristor controlled reactor (FC-TCR type of power factor compensator with different series R-L load is analyzed using an approximate circuit. The variation of reactive power and power factor before and after compensation is examined. The simulation is carried out in PSIM software for 3-phase 440 volt. The close loop control is possible for different load condition. Automatic firing angle is adjusted such that minimum VAR taken from the supply & power factor is maintain near to unity.

  10. MFM Automatic Control System Development for CYCIAE-100

    Institute of Scientific and Technical Information of China (English)

    CAO; Lei; YIN; Zhi-guo; LV; Yin-long; ZHONG; Jun-qing

    2012-01-01

    <正>In order to do the magnetic field measurement (MFM) work for CYCIAE-100, a set of MFM automatic facility has been developed by the cyclotron team at CIAE. 1 Design of project The MFM facility for CYCIAE-100 adopts the method of circular and radial motion to complete the measurement. In circular direction, an open loop control is adopted at hardware level. A kind of arithmetic is compensated to form a virtual closed loop control based on the position signal by angle encoder

  11. Automatic and controlled processing and the Broad Autism Phenotype.

    Science.gov (United States)

    Camodeca, Amy; Voelker, Sylvia

    2016-01-30

    Research related to verbal fluency in the Broad Autism Phenotype (BAP) is limited and dated, but generally suggests intact abilities in the context of weaknesses in other areas of executive function (Hughes et al., 1999; Wong et al., 2006; Delorme et al., 2007). Controlled processing, the generation of search strategies after initial, automated responses are exhausted (Spat, 2013), has yet to be investigated in the BAP, and may be evidenced in verbal fluency tasks. One hundred twenty-nine participants completed the Delis-Kaplan Executive Function System Verbal Fluency test (D-KEFS; Delis et al., 2001) and the Broad Autism Phenotype Questionnaire (BAPQ; Hurley et al., 2007). The BAP group (n=53) produced significantly fewer total words during the 2nd 15" interval compared to the Non-BAP (n=76) group. Partial correlations indicated similar relations between verbal fluency variables for each group. Regression analyses predicting 2nd 15" interval scores suggested differentiation between controlled and automatic processing skills in both groups. Results suggest adequate automatic processing, but slowed development of controlled processing strategies in the BAP, and provide evidence for similar underlying cognitive constructs for both groups. Controlled processing was predictive of Block Design score for Non-BAP participants, and was predictive of Pragmatic Language score on the BAPQ for BAP participants. These results are similar to past research related to strengths and weaknesses in the BAP, respectively, and suggest that controlled processing strategy use may be required in instances of weak lower-level skills. PMID:26652842

  12. Patient ECG recording control for an automatic implantable defibrillator

    Science.gov (United States)

    Fountain, Glen H. (Inventor); Lee, Jr., David G. (Inventor); Kitchin, David A. (Inventor)

    1986-01-01

    An implantable automatic defibrillator includes sensors which are placed on or near the patient's heart to detect electrical signals indicative of the physiology of the heart. The signals are digitally converted and stored into a FIFO region of a RAM by operation of a direct memory access (DMA) controller. The DMA controller operates transparently with respect to the microprocessor which is part of the defibrillator. The implantable defibrillator includes a telemetry communications circuit for sending data outbound from the defibrillator to an external device (either a patient controller or a physician's console or other) and a receiver for sensing at least an externally generated patient ECG recording command signal. The patient recording command signal is generated by the hand held patient controller. Upon detection of the patient ECG recording command, DMA copies the contents of the FIFO into a specific region of the RAM.

  13. Consistently Trained Artificial Neural Network for Automatic Ship Berthing Control

    Directory of Open Access Journals (Sweden)

    Y.A. Ahmed

    2015-09-01

    Full Text Available In this paper, consistently trained Artificial Neural Network controller for automatic ship berthing is discussed. Minimum time course changing manoeuvre is utilised to ensure such consistency and a new concept named ‘virtual window’ is introduced. Such consistent teaching data are then used to train two separate multi-layered feed forward neural networks for command rudder and propeller revolution output. After proper training, several known and unknown conditions are tested to judge the effectiveness of the proposed controller using Monte Carlo simulations. After getting acceptable percentages of success, the trained networks are implemented for the free running experiment system to judge the network’s real time response for Esso Osaka 3-m model ship. The network’s behaviour during such experiments is also investigated for possible effect of initial conditions as well as wind disturbances. Moreover, since the final goal point of the proposed controller is set at some distance from the actual pier to ensure safety, therefore a study on automatic tug assistance is also discussed for the final alignment of the ship with actual pier.

  14. Automatic Voltage Control (AVC) System under Uncertainty from Wind Power

    DEFF Research Database (Denmark)

    Qin, Nan; Abildgaard, Hans; Flynn, Damian;

    2016-01-01

    An automatic voltage control (AVC) system maintains the voltage profile of a power system in an acceptable range and minimizes the operational cost by coordinating the regulation of controllable components. Typically, all of the parameters in the optimization problem are assumed to be certain...... and constant in the decision making process. However, for high shares of wind power, uncertainty in the decision process due to wind power variability may result in an infeasible AVC solution. This paper proposes a voltage control approach which considers the voltage uncertainty from wind power productions....... The proposed method improves the performance and the robustness of a scenario based approach by estimating the potential voltage variations due to fluctuating wind power production, and introduces a voltage margin to protect the decision against uncertainty for each scenario. The effectiveness of the proposed...

  15. On-line current feed and computer aided control tactics for automatic balancing head

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    In the designed automatic balancing head,a non-contact induction transformer is used to deliver driving energy to solve the problem of current fed and controlling on-line.Computer controlled automatic balancing experiments with phase-magnitude control tactics were performed on a flexible rotor system.Results of the experiments prove that the energy feeding method and the control tactics are effective in the automatic balancing head for vibration controlling.

  16. Automatic Overset Grid Generation with Heuristic Feedback Control

    Science.gov (United States)

    Robinson, Peter I.

    2001-01-01

    An advancing front grid generation system for structured Overset grids is presented which automatically modifies Overset structured surface grids and control lines until user-specified grid qualities are achieved. The system is demonstrated on two examples: the first refines a space shuttle fuselage control line until global truncation error is achieved; the second advances, from control lines, the space shuttle orbiter fuselage top and fuselage side surface grids until proper overlap is achieved. Surface grids are generated in minutes for complex geometries. The system is implemented as a heuristic feedback control (HFC) expert system which iteratively modifies the input specifications for Overset control line and surface grids. It is developed as an extension of modern control theory, production rules systems and subsumption architectures. The methodology provides benefits over the full knowledge lifecycle of an expert system for knowledge acquisition, knowledge representation, and knowledge execution. The vector/matrix framework of modern control theory systematically acquires and represents expert system knowledge. Missing matrix elements imply missing expert knowledge. The execution of the expert system knowledge is performed through symbolic execution of the matrix algebra equations of modern control theory. The dot product operation of matrix algebra is generalized for heuristic symbolic terms. Constant time execution is guaranteed.

  17. Automatic Thermal Control System with Temperature Difference or Derivation Feedback

    Directory of Open Access Journals (Sweden)

    Darina Matiskova

    2016-02-01

    Full Text Available Automatic thermal control systems seem to be non-linear systems with thermal inertias and time delay. A controller is also non-linear because its information and power signals are limited. The application of methods that are available to on-linear systems together with computer simulation and mathematical modelling creates a possibility to acquire important information about the researched system. This paper provides a new look at the heated system model and also designs the structure of the thermal system with temperature derivation feedback. The designed system was simulated by using a special software in Turbo Pascal. Time responses of this system are compared to responses of a conventional thermal system. The thermal system with temperature derivation feedback provides better transients, better quality of regulation and better dynamical properties.

  18. Towards Automatic Controller Design using Multi-Objective Evolutionary Algorithms

    DEFF Research Database (Denmark)

    Pedersen, Gerulf

    of evolutionary computation, a choice was made to use multi-objective algorithms for the purpose of aiding in automatic controller design. More specifically, the choice was made to use the Non-dominated Sorting Genetic Algorithm II (NSGAII), which is one of the most potent algorithms currently in use......In order to design the controllers of tomorrow, a need has risen for tools that can aid in the design of these. A desire to use evolutionary computation as a tool to achieve that goal is what gave inspiration for the work contained in this thesis. After having studied the foundations......, as the foundation for achieving the desired goal. While working with the algorithm, some issues arose which limited the use of the algorithm for unknown problems. These issues included the relative scale of the used fitness functions and the distribution of solutions on the optimal Pareto front. Some work has...

  19. Automatic Meter Reading and Theft Control System by Using GSM

    Directory of Open Access Journals (Sweden)

    P. Rakesh Malhotra

    2013-04-01

    Full Text Available This paper deals with automatic meter reading and theft control system in energy meter. Current transformer is used to measure the total power consumption for house or industrial purpose. This recorded reading is transmitted to the electricity board for every 60 days once. For transmitting the reading of energy meter GSM module is used. To avoid theft, infrared sensor is placed in the screw portion of energy meter seal. If the screw is removed from the meter a message is sent to the electricity board. The measuring of energy meter and monitoring of IR sensor is done with a PIC microcontroller.The informative system will be helpful for the electricity board to monitor the entire supply and the correct billing accordingly without any mishap. This model reduces the manual manipulation work andtheft control.

  20. Automatic Level Control for Video Cameras towards HDR Techniques

    Directory of Open Access Journals (Sweden)

    de With PeterHN

    2010-01-01

    Full Text Available We give a comprehensive overview of the complete exposure processing chain for video cameras. For each step of the automatic exposure algorithm we discuss some classical solutions and propose their improvements or give new alternatives. We start by explaining exposure metering methods, describing types of signals that are used as the scene content descriptors as well as means to utilize these descriptors. We also discuss different exposure control types used for the control of lens, integration time of the sensor, and gain control, such as a PID control, precalculated control based on the camera response function, and propose a new recursive control type that matches the underlying image formation model. Then, a description of commonly used serial control strategy for lens, sensor exposure time, and gain is presented, followed by a proposal of a new parallel control solution that integrates well with tone mapping and enhancement part of the image pipeline. Parallel control strategy enables faster and smoother control and facilitates optimally filling the dynamic range of the sensor to improve the SNR and an image contrast, while avoiding signal clipping. This is archived by the proposed special control modes used for better display and correct exposure of both low-dynamic range and high-dynamic range images. To overcome the inherited problems of limited dynamic range of capturing devices we discuss a paradigm of multiple exposure techniques. Using these techniques we can enable a correct rendering of difficult class of high-dynamic range input scenes. However, multiple exposure techniques bring several challenges, especially in the presence of motion and artificial light sources such as fluorescent lights. In particular, false colors and light-flickering problems are described. After briefly discussing some known possible solutions for the motion problem, we focus on solving the fluorescence-light problem. Thereby, we propose an algorithm for

  1. OPTIMAL CONTROL APPLIED IN AUTOMATIC CLUTCH ENGAGEMENTS OF VEHICLES

    Institute of Scientific and Technical Information of China (English)

    Sun Chengshun; Zhang Jianwu

    2004-01-01

    Start-up working condition is the key to the research of optimal engagement of automatic clutch for AMT.In order to guarantee an ideal dynamic performance of the clutch engagement,an optimal controller is designed by considering throttle angle,engine speed,gear ratio,vehicle acceleration and road condition.The minimum value principle is also introduced to achieve an optimal dynamic performance of the nonlinear system compromised in friction plate wear and vehicle drive quality.The optimal trajectory of the clutch engagement can be described in the form of explicit and analytical expressions and characterized by the deterministic and accurate control strategy in stead of indeterministic and soft control techniques which need thousands of experiments.For validation of the controller,test work is carried out for the automated clutch engagements in a commercial car with an traditional mechanical transmission,a hydraulic actuator,a group of sensors and a portable computer system.It is shown through experiments that dynamic behaviors of the clutch engagement operated by the optimal control are more effective and efficient than those by fuzzy control.

  2. Robust parameter design for automatically controlled systems and nanostructure synthesis

    Science.gov (United States)

    Dasgupta, Tirthankar

    2007-12-01

    This research focuses on developing comprehensive frameworks for developing robust parameter design methodology for dynamic systems with automatic control and for synthesis of nanostructures. In many automatically controlled dynamic processes, the optimal feedback control law depends on the parameter design solution and vice versa and therefore an integrated approach is necessary. A parameter design methodology in the presence of feedback control is developed for processes of long duration under the assumption that experimental noise factors are uncorrelated over time. Systems that follow a pure-gain dynamic model are considered and the best proportional-integral and minimum mean squared error control strategies are developed by using robust parameter design. The proposed method is illustrated using a simulated example and a case study in a urea packing plant. This idea is also extended to cases with on-line noise factors. The possibility of integrating feedforward control with a minimum mean squared error feedback control scheme is explored. To meet the needs of large scale synthesis of nanostructures, it is critical to systematically find experimental conditions under which the desired nanostructures are synthesized reproducibly, at large quantity and with controlled morphology. The first part of the research in this area focuses on modeling and optimization of existing experimental data. Through a rigorous statistical analysis of experimental data, models linking the probabilities of obtaining specific morphologies to the process variables are developed. A new iterative algorithm for fitting a Multinomial GLM is proposed and used. The optimum process conditions, which maximize the above probabilities and make the synthesis process less sensitive to variations of process variables around set values, are derived from the fitted models using Monte-Carlo simulations. The second part of the research deals with development of an experimental design methodology, tailor

  3. Human interface, automatic planning, and control of a humanoid robot

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Y.K. [Korea Inst. of Science and Technology, Seoul (Korea, Republic of)]|[Sandia National Labs., Albuquerque, NM (United States); Kang, S.C.; Lee, S.; Cho, K.R.; Kim, H.S.; Lee, C.W. [Korea Inst. of Science and Technology, Seoul (Korea, Republic of); Park, S.M. [Jeonju Technical Coll. (Korea, Republic of)

    1998-11-01

    This paper presents an integrated robotic system consisting of human interfaces, motion- and grasp-planning algorithms, a controller, a graphical simulator, and a humanoid robot with over 60 joints. All of these subsystems are integrated in a coordinated fashion to enable the robot to perform a commanded task with as much autonomy as possible. The highest level of the system is the human interfaces, which enable a user to specify tasks conveniently and efficiently. At the mid-level, several planning algorithms generate motions of the robot body, arms, and hands automatically. At the lowest level, the motor controllers are equipped with both a position controller and a compliant motion controller to execute gross motions and contact motions, respectively. The main contributions of the work are the large-scale integration and the development of the motion planners for a humanoid robot. A hierarchical integration scheme that preserves the modularities of the human interfaces, the motion planners, and the controller has been the key for the successful integration. The set of motion planners is developed systematically so as to coordinate the motions of the body, arms, and hands to perform a large variety of tasks.

  4. Modeling of a Multiple Digital Automatic Gain Control System

    Institute of Scientific and Technical Information of China (English)

    WANG Jingdian; LU Xiuhong; ZHANG Li

    2008-01-01

    Automatic gain control (AGC) has been used in many applications. The key features of AGC, including a steady state output and static/dynamic timing response, depend mainly on key parameters such as the reference and the filter coefficients. A simple model developed to describe AGC systems based on several simple assumptions shows that AGC always converges to the reference and that the timing constant depends on the filter coefficients. Measures are given to prevent oscillations and limit cycle effects. The simple AGC system is adapted to a multiple AGC system for a TV tuner in a much more efficient model. Simulations using the C language are 16 times faster than those with MATLAB, and 10 times faster than those with a mixed register transfer level (RTL)-simulation program with integrated circuit emphasis (SPICE) model.

  5. Research on key control technologies of all-position automatic welding machine

    Institute of Scientific and Technical Information of China (English)

    Zeng Huilin; Du Zeyu; Ma Jing; Huang Fuxiang

    2009-01-01

    The pipeline all-position automatic welding machine system is a special welding system for automatically welding circumferential joint of pipeline on site, which has been widely used to the long-distance pipeline construction projects due to the advantages of automatic control for welding parameters at all-position, moving speed of bugs and operating. In this paper, the key control technologies of PAWM all-position automatic welding machine (developed by Pipeline Research Institute of CNPC) such as the automatic control system, control software, personal digital assistant (PDA) software and complex programmable logic device(CPLD) program as well as the control method of welding parameter have been described detailedly. With the higher welding quality, higher welding efficiency and lower labor intensity, PAWM all-position automatic welding machine has been successfully applied in many famous pipeline construction projects.

  6. Effectiveness of Automatic Control over Flash Distillation Kettle for Liquid-Phase Bulk Polymerization of Propylene

    Institute of Scientific and Technical Information of China (English)

    Han Linge; Ma Jiantong

    2004-01-01

    Automatic control over flash distillation section at SINOPEC Cangzhou Refinery has been realized, resulting in saving of propylene feedstock and emission reduction to harvest significant economic benefits.

  7. Automatic control system for uniformly paving iron ore pellets

    Science.gov (United States)

    Wang, Bowen; Qian, Xiaolong

    2014-05-01

    In iron and steelmaking industry, iron ore pellet qualities are crucial to end-product properties, manufacturing costs and waste emissions. Uniform pellet pavements on the grate machine are a fundamental prerequisite to ensure even heat-transfer and pellet induration successively influences performance of the following metallurgical processes. This article presents an automatic control system for uniformly paving green pellets on the grate, via a mechanism mainly constituted of a mechanical linkage, a swinging belt, a conveyance belt and a grate. Mechanism analysis illustrates that uniform pellet pavements demand the frontend of the swinging belt oscillate at a constant angular velocity. Subsequently, kinetic models are formulated to relate oscillatory movements of the swinging belt's frontend to rotations of a crank link driven by a motor. On basis of kinetic analysis of the pellet feeding mechanism, a cubic B-spline model is built for numerically computing discrete frequencies to be modulated during a motor rotation. Subsequently, the pellet feeding control system is presented in terms of compositional hardware and software components, and their functional relationships. Finally, pellet feeding experiments are carried out to demonstrate that the control system is effective, reliable and superior to conventional methods.

  8. Solar Driven Automatic Water Level Controller with Dry Run Protection

    Directory of Open Access Journals (Sweden)

    V. Ravikiran,

    2015-11-01

    Full Text Available This paper presents solar driven automatic water level controller with dry run protection (SDWLC. The main purpose of SDWLC is to reduce wastage of water, to stop dry running of motor and to use solar energy effectively by using PV system. Generally water is pumped to overheadtank (OHT from undergroundtank (UGT.People will switch on pump when taps go dry, switch off pump when water over flows and they does not check dry running of motor during this. Also pumping of water to OHT during power cuts is a major problem in most of villages and in some of cities. However these problems can be solved by SDWLC. By using inverter the DC generated from PV system is converted in to AC and given to the motor. The operation of water level controller works upon the fact that water conducts electricity. So water can be used to open or close a circuit. As the water level rises or falls, different circuits in the controller send different signals. These signals are used to switch ON or switch OFF the motor pump as per our requirements.

  9. Automatic Tuning of PID Controller for a 1-D Levitation System Using a Genetic Algorithm

    DEFF Research Database (Denmark)

    Yang, Zhenyu; Pedersen, Gerulf K.m.

    2006-01-01

    The automatic PID control design for a onedimensional magnetic levitation system is investigated. The PID controller is automatically tuned using the non-dominated sorting genetic algorithm (NSGA-II) based on a nonlinear system model. The developed controller is digitally implemented and tested...

  10. A device for automatic photoelectric control of the analytical gap for emission spectrographs

    Science.gov (United States)

    Dietrich, John A.; Cooley, Elmo F.; Curry, Kenneth J.

    1977-01-01

    A photoelectric device has been built that automatically controls the analytical gap between electrodes during excitation period. The control device allows for precise control of the analytical gap during the arcing process of samples, resulting in better precision of analysis.

  11. Research and application of Automatic Voltage Control in Tongbai Pumped Storage Power Station

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    The Automatic Voltage Control is significant technique of modem power grid operation, and it is one of important function of intelligent grid management, it plays an important role to ensure the security, high quality and economical operation of power grid. This paper introduces the research and application of Automatic Voltage Control in Tongtai Pumped Storage Power Station.

  12. Dynamic Optimization of Feedforward Automatic Gauge Control Based on Extended Kalman Filter

    Institute of Scientific and Technical Information of China (English)

    YANG Bin-hu; YANG Wei-dong; CHEN Lian-gui; QU Lei

    2008-01-01

    Automatic gauge control is an essentially nonlinear process varying with time delay, and stochastically varying input and process noise always influence the target gauge control accuracy. To improve the control capability of feedforward automatic gauge control, Kalman filter was employed to filter the noise signal transferred from one stand to another. The linearized matrix that the Kalman filter algorithm needed was concluded; thus, the feedforward automatic gauge control architecture was dynamically optimized. The theoretical analyses and simulation show that the proposed algorithm is reasonable and effective.

  13. Devises of automatic for controling of microwave stove for food products’ incinerating

    Directory of Open Access Journals (Sweden)

    M. O. Gren

    2008-05-01

    Full Text Available Development of automatic meant for controlling of microwave oven with the possibility of work on the base of few magnetrons and controlling temperature at the same time with VSWR are represented.

  14. The Influence of Dopamine on Automatic and Controlled Semantic Activation in Parkinson's Disease

    Directory of Open Access Journals (Sweden)

    Wendy L. Arnott

    2011-01-01

    Full Text Available Two semantic priming tasks, designed to isolate automatic and controlled semantic activation, were utilized to investigate the impact of dopamine depletion on semantic processing in Parkinson's disease (PD. Seven people with PD (tested whilst on and off levodopa medication and seven healthy adults participated in the study. The healthy adult participants demonstrated intact automatic and controlled semantic activation. Aberrant controlled semantic activation was observed in the PD group on levodopa; however, automatic semantic activation was still evident. In contrast, automatic semantic activation was not evident in the PD group off levodopa. These results further clarify the impact of PD on semantic processing, demonstrating that dopamine depletion can cause disturbances in both automatic and controlled semantic activation.

  15. AUTOMATIC GENERATION CONTROL OF MULTI AREA POWER SYSTEMS USING ANN CONTROLLER

    Directory of Open Access Journals (Sweden)

    Bipasha Bhatia

    2012-07-01

    Full Text Available This paper presents the use of one of the methods of artificial intelligence to study the automatic generation control of interconnected power systems. In the given paper, a control line of track is established for interconnected three area thermal-thermal-thermal power system using generation rate constraints (GRC &Artificial Neural Network (ANN. The working of the controllers is simulated using MATLAB/SIMULINK package. The outputs using both controllers are compared and it is established that ANN based approach is better than GRC for 1% step load conditions.

  16. Fuzzy logic control strategy for submerged arc automatic welding of digital controlling

    Institute of Scientific and Technical Information of China (English)

    He Kuanfang; Huang Shisheng; Zhou Yiqing; Wang Zhenmin

    2008-01-01

    A microcomputer control system based on 80C320 and a switching regulation of wire feeder were designed. A correction factor based double model fuzzy logic controller (FLC) was introduced to achieve welding digital and intellectualized control by means of wire feeding speed feedback. The controller has many functions such as keyboard input, light emitting diode (LED) display and real-time intellectualized control of welding process etc. The controlling performance influenced by the coefficient of correction function was discussed. It was concluded by the experiments the relation between the coefftcient of correction function and welding quality, when the coefficient of correction function is great, the dynamic character of controller is better, when the coefficient of correction function is small, the sensitivity character of controller is better. Experimental results also show that digital and fuzzy logic control method enable the improvement of appearance of weld and stability of welding process to be achieved in submerged arc automatic welding.

  17. Evaluation of automatic exposure control systems in computed tomography

    International Nuclear Information System (INIS)

    The development of the computed tomography (CT) technology has brought wider possibilities on diagnostic medicine. It is a non-invasive method to see the human body in details. As the CT application increases, it raises the concern about patient dose, because the higher dose levels imparted compared to other diagnostic imaging modalities. The radiology community (radiologists, medical physicists and manufacturer) are working together to find the lowest dose level possible, without compromising the diagnostic image quality. The greatest and relatively new advance to lower the patient dose is the automatic exposure control (AEC) systems in CT. These systems are designed to ponder the dose distribution along the patient scanning and between patients taking into account their sizes and irradiated tissue densities. Based on the CT scanning geometry, the AEC-systems are very complex and their functioning is yet not fully understood. This work aims to evaluate the clinical performance of AEC-systems and their susceptibilities to assist on possible patient dose optimizations. The approach to evaluate the AEC-systems of three of the leading CT manufacturers in Brazil, General Electric, Philips and Toshiba, was the extraction of tube current modulation data from the DICOM standard image sequences, measurement and analysis of the image noise of those image sequences and measurement of the dose distribution along the scan length on the surface and inside of two different phantoms configurations. The tube current modulation of each CT scanner associated to the resulted image quality provides the performance of the AECsystem. The dose distribution measurements provide the dose profile due to the tube current modulation. Dose measurements with the AEC-system ON and OFF were made to quantify the impact of these systems regarding patient dose. The results attained give rise to optimizations on the AEC-systems applications and, by consequence, decreases the patient dose without

  18. Automatic analysis of signals during Eddy currents controls

    International Nuclear Information System (INIS)

    A method and the corresponding instrument have been developed for automatic analysis of Eddy currents testing signals. This apparatus enables at the same time the analysis, every 2 milliseconds, of two signals at two different frequencies. It can be used either on line with an Eddy Current testing instrument or with a magnetic tape recorder

  19. ISS Contingency Attitude Control Recovery Method for Loss of Automatic Thruster Control

    Science.gov (United States)

    Bedrossian, Nazareth; Bhatt, Sagar; Alaniz, Abran; McCants, Edward; Nguyen, Louis; Chamitoff, Greg

    2008-01-01

    In this paper, the attitude control issues associated with International Space Station (ISS) loss of automatic thruster control capability are discussed and methods for attitude control recovery are presented. This scenario was experienced recently during Shuttle mission STS-117 and ISS Stage 13A in June 2007 when the Russian GN&C computers, which command the ISS thrusters, failed. Without automatic propulsive attitude control, the ISS would not be able to regain attitude control after the Orbiter undocked. The core issues associated with recovering long-term attitude control using CMGs are described as well as the systems engineering analysis to identify recovery options. It is shown that the recovery method can be separated into a procedure for rate damping to a safe harbor gravity gradient stable orientation and a capability to maneuver the vehicle to the necessary initial conditions for long term attitude hold. A manual control option using Soyuz and Progress vehicle thrusters is investigated for rate damping and maneuvers. The issues with implementing such an option are presented and the key issue of closed-loop stability is addressed. A new non-propulsive alternative to thruster control, Zero Propellant Maneuver (ZPM) attitude control method is introduced and its rate damping and maneuver performance evaluated. It is shown that ZPM can meet the tight attitude and rate error tolerances needed for long term attitude control. A combination of manual thruster rate damping to a safe harbor attitude followed by a ZPM to Stage long term attitude control orientation was selected by the Anomaly Resolution Team as the alternate attitude control method for such a contingency.

  20. Automatic control logics to eliminate xenon oscillation based on Axial Offsets Trajectory Method

    Energy Technology Data Exchange (ETDEWEB)

    Shimazu, Yoichiro [Mitsubishi Heavy Industries Ltd., Yokohama (Japan). Nuclear Energy Systems Engineering Center

    1996-06-01

    We have proposed Axial Offsets (AO) Trajectory Method for xenon oscillation control in pressurized water reactors. The features of this method are described as such that it can clearly give necessary control operations to eliminate xenon oscillations. It is expected that using the features automatic control logics for xenon oscillations can be simple and be realized easily. We investigated automatic control logics. The AO Trajectory Method could realize a very simple logic only for eliminating xenon oscillations. However it was necessary to give another considerations to eliminate the xenon oscillation with a given axial power distribution. The other control logic based on the modern control theory was also studied for comparison of the control performance of the new control logic. As the results, it is presented that the automatic control logics based on the AO Trajectory Method are very simple and effective. (author).

  1. Automatic control logics to eliminate xenon oscillation based on Axial Offsets Trajectory Method

    International Nuclear Information System (INIS)

    We have proposed Axial Offsets (AO) Trajectory Method for xenon oscillation control in pressurized water reactors. The features of this method are described as such that it can clearly give necessary control operations to eliminate xenon oscillations. It is expected that using the features automatic control logics for xenon oscillations can be simple and be realized easily. We investigated automatic control logics. The AO Trajectory Method could realize a very simple logic only for eliminating xenon oscillations. However it was necessary to give another considerations to eliminate the xenon oscillation with a given axial power distribution. The other control logic based on the modern control theory was also studied for comparison of the control performance of the new control logic. As the results, it is presented that the automatic control logics based on the AO Trajectory Method are very simple and effective. (author)

  2. Automatic sleep staging using state machine-controlled decision trees.

    Science.gov (United States)

    Imtiaz, Syed Anas; Rodriguez-Villegas, Esther

    2015-01-01

    Automatic sleep staging from a reduced number of channels is desirable to save time, reduce costs and make sleep monitoring more accessible by providing home-based polysomnography. This paper introduces a novel algorithm for automatic scoring of sleep stages using a combination of small decision trees driven by a state machine. The algorithm uses two channels of EEG for feature extraction and has a state machine that selects a suitable decision tree for classification based on the prevailing sleep stage. Its performance has been evaluated using the complete dataset of 61 recordings from PhysioNet Sleep EDF Expanded database achieving an overall accuracy of 82% and 79% on training and test sets respectively. The algorithm has been developed with a very small number of decision tree nodes that are active at any given time making it suitable for use in resource-constrained wearable systems.

  3. Automatic Control of Freeboard and Turbine Operation:Wave Dragon, Nissum Bredning

    OpenAIRE

    Kofoed, Jens Peter; Frigaard, Peter Bak; Friis-Madsen, Erik; Nimskov, Morten

    2004-01-01

    The report deals with the modules for automatic control of freeboard and turbine operation on board the Wave dragon, Nissum Bredning (WD-NB) prototype, and covers what has been going on up to ultimo 2003.

  4. Intelligent buildings, automatic fire alarm and fire-protection control system

    International Nuclear Information System (INIS)

    The author describes in brief the intelligent buildings, and the automatic fire alarm and fire-protection control system. On the basis of the four-bus, three-bus and two-bus, a new transfer technique was developed

  5. Implementation of a remote computer controlled automatic guided vehicle

    OpenAIRE

    Lu, Roberto F.

    1994-01-01

    The effectiveness of a material handling system is essential to a competitive manufacturing environment. Automatic Guided Vehicles (AGVs) are an irnportant technology within today's modern manufacturing facility. Academic programs in manufacturing and industrial engineering must find ways to include this technology in their instructional and research programs to provide the students with sufficient knowledge to address material handling systems design. This project was a fir...

  6. Automatic detection of AutoPEEP during controlled mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Nguyen Quang-Thang

    2012-06-01

    Full Text Available Abstract Background Dynamic hyperinflation, hereafter called AutoPEEP (auto-positive end expiratory pressure with some slight language abuse, is a frequent deleterious phenomenon in patients undergoing mechanical ventilation. Although not readily quantifiable, AutoPEEP can be recognized on the expiratory portion of the flow waveform. If expiratory flow does not return to zero before the next inspiration, AutoPEEP is present. This simple detection however requires the eye of an expert clinician at the patient’s bedside. An automatic detection of AutoPEEP should be helpful to optimize care. Methods In this paper, a platform for automatic detection of AutoPEEP based on the flow signal available on most of recent mechanical ventilators is introduced. The detection algorithms are developed on the basis of robust non-parametric hypothesis testings that require no prior information on the signal distribution. In particular, two detectors are proposed: one is based on SNT (Signal Norm Testing and the other is an extension of SNT in the sequential framework. The performance assessment was carried out on a respiratory system analog and ex-vivo on various retrospectively acquired patient curves. Results The experiment results have shown that the proposed algorithm provides relevant AutoPEEP detection on both simulated and real data. The analysis of clinical data has shown that the proposed detectors can be used to automatically detect AutoPEEP with an accuracy of 93% and a recall (sensitivity of 90%. Conclusions The proposed platform provides an automatic early detection of AutoPEEP. Such functionality can be integrated in the currently used mechanical ventilator for continuous monitoring of the patient-ventilator interface and, therefore, alleviate the clinician task.

  7. The TS 600: automatic control system for eddy currents

    International Nuclear Information System (INIS)

    In the scope of fabrication and in service inspection of the PWR steam generator tubing bendle, FRAMATOME developed an automatic Eddy Current testing system: TS600. Based on a mini-computer, TS600 allows to digitize, to store and to process data in various ways, so it is possible to perform several kinds of inspection: conventional inservice inspection, roll area profilometry...... TS600 can also be used to develop new methods of examination

  8. The development of automatic and controlled inhibitory retrieval processes in true and false recall

    OpenAIRE

    Knott, L.; Howe, M. L.; Wimmer, M. C.; Dewhurst, S

    2011-01-01

    In three experiments we investigated the role of automatic and controlled inhibitory retrieval processes in true and false memory development in children and adults. Experiment 1 incorporated a directed forgetting task to examine controlled retrieval inhibition. Experiments 2 and 3 utilized a part-set cue and retrieval practice task to examine automatic retrieval inhibition. In the first experiment, the forget cue had no effect on false recall for adults but reduced false recall for children....

  9. Tailoring automatic exposure control toward constant detectability in digital mammography

    Energy Technology Data Exchange (ETDEWEB)

    Salvagnini, Elena, E-mail: elena.salvagnini@uzleuven.be [Department of Imaging and Pathology, Medical Physics and Quality Assessment, KUL, Herestraat 49, Leuven B-3000, Belgium and SCK-CEN, Boeretang 200, Mol 2400 (Belgium); Bosmans, Hilde [Department of Imaging and Pathology, Medical Physics and Quality Assessment, KUL, Herestraat 49, Leuven B-3000, Belgium and Department of Radiology, UZ Gasthuisberg, Herestraat 49, Leuven B-3000 (Belgium); Struelens, Lara [SCK-CEN, Boeretang 200, Mol 2400 (Belgium); Marshall, Nicholas W. [Department of Radiology, UZ Gasthuisberg, Herestraat 49, Leuven B-3000 (Belgium)

    2015-07-15

    Purpose: The automatic exposure control (AEC) modes of most full field digital mammography (FFDM) systems are set up to hold pixel value (PV) constant as breast thickness changes. This paper proposes an alternative AEC mode, set up to maintain some minimum detectability level, with the ultimate goal of improving object detectability at larger breast thicknesses. Methods: The default “OPDOSE” AEC mode of a Siemens MAMMOMAT Inspiration FFDM system was assessed using poly(methyl methacrylate) (PMMA) of thickness 20, 30, 40, 50, 60, and 70 mm to find the tube voltage and anode/filter combination programmed for each thickness; these beam quality settings were used for the modified AEC mode. Detectability index (d′), in terms of a non-prewhitened model observer with eye filter, was then calculated as a function of tube current-time product (mAs) for each thickness. A modified AEC could then be designed in which detectability never fell below some minimum setting for any thickness in the operating range. In this study, the value was chosen such that the system met the achievable threshold gold thickness (T{sub t}) in the European guidelines for the 0.1 mm diameter disc (i.e., T{sub t} ≤ 1.10 μm gold). The default and modified AEC modes were compared in terms of contrast-detail performance (T{sub t}), calculated detectability (d′), signal-difference-to-noise ratio (SDNR), and mean glandular dose (MGD). The influence of a structured background on object detectability for both AEC modes was examined using a CIRS BR3D phantom. Computer-based CDMAM reading was used for the homogeneous case, while the images with the BR3D background were scored by human observers. Results: The default OPDOSE AEC mode maintained PV constant as PMMA thickness increased, leading to a reduction in SDNR for the homogeneous background 39% and d′ 37% in going from 20 to 70 mm; introduction of the structured BR3D plate changed these figures to 22% (SDNR) and 6% (d′), respectively

  10. Research on automatic current sharing control methods for control power supply

    Directory of Open Access Journals (Sweden)

    Dai Xian Bin

    2016-01-01

    Full Text Available High-power switching devices in control power supply have different saturated forward voltage drops and the inconsistency of turning on/off times and they lead to the inconsistency in the external characteristics of the inverter modules in parallel operation. Modules with good performance in external characteristics undertake more currents and lead to overloading status and modules with bad performance in external characteristics stay in light-loading status, which increases the thermal stress of module undertaking more currents and influences the service life of high-power switching devices. Based on the simulation analysis of the small-signal module using control power supply automatic current sharing method, it is able to find out the characteristics of current-sharing loop control, namely, slow response speed of the current-sharing loop, which is beneficial for improving the stability of the entire control power supply system.

  11. Development and implementation of an automatic control algorithm for the University of Utah nuclear reactor

    International Nuclear Information System (INIS)

    The emphasis of this work is the development and implementation of an automatic control philosophy which uses the classical operational philosophies as a foundation. Three control algorithms were derived based on various simplifying assumptions. Two of the algorithms were tested in computer simulations. After realizing the insensitivity of the system to the simplifications, the most reduced form of the algorithms was implemented on the computer control system at the University of Utah (UNEL). Since the operational philosophies have a higher priority than automatic control, they determine when automatic control may be utilized. Unlike the operational philosophies, automatic control is not concerned with component failures. The object of this philosophy is the movement of absorber rods to produce a requested power. When the current power level is compared to the requested power level, an error may be detected which will require the movement of a control rod to correct the error. The automatic control philosophy adds another dimension to the classical operational philosophies. Using this philosophy, normal operator interactions with the computer would be limited only to run parameters such as power, period, and run time. This eliminates subjective judgements, objective judgements under pressure, and distractions to the operator and insures the reactor will be operated in a safe and controlled manner as well as providing reproducible operations

  12. General collaboration offer of Johnson Controls regarding the performance of air conditioning automatic control systems and other buildings` automatic control systems

    Energy Technology Data Exchange (ETDEWEB)

    Gniazdowski, J.

    1995-12-31

    JOHNSON CONTROLS manufactures measuring and control equipment (800 types) and is as well a {open_quotes}turn-key{close_quotes} supplier of complete automatic controls systems for heating, air conditioning, ventilation and refrigerating engineering branches. The Company also supplies Buildings` Computer-Based Supervision and Monitoring Systems that may be applied in both small and large structures. Since 1990 the company has been performing full-range trade and contracting activities on the Polish market. We have our own well-trained technical staff and we collaborate with a series of designing and contracting enterprises that enable us to have our projects carried out all over Poland. The prices of our supplies and services correspond with the level of the Polish market.

  13. Automatic SIMD vectorization of SSA-based control flow graphs

    CERN Document Server

    Karrenberg, Ralf

    2015-01-01

    Ralf Karrenberg presents Whole-Function Vectorization (WFV), an approach that allows a compiler to automatically create code that exploits data-parallelism using SIMD instructions. Data-parallel applications such as particle simulations, stock option price estimation or video decoding require the same computations to be performed on huge amounts of data. Without WFV, one processor core executes a single instance of a data-parallel function. WFV transforms the function to execute multiple instances at once using SIMD instructions. The author describes an advanced WFV algorithm that includes a v

  14. Automatic flatness control strategy with a Smith predictor for steel strip rolling

    Science.gov (United States)

    Zhang, Ruicheng; Zheng, Xin

    2011-10-01

    The simplified transfer function diagram block for a automatic flatness control (AFC) system of strip steel rolling process was investigated. For the problem of automatic flatness control (AFC) in cold tandem mills this paper proposes control techniques based on Smith predictor to compensate for the numerous delays present in the mill. After a Smith predictor was used to the AFC system, the control laws were deduced for both proportional and integral regulators. Control algorithms are tested in simulation considering a tandem mill with four stands as a benchmark, and results are shown to demonstrate the performance of the proposed schemes.

  15. Analysis and Design of PLC-based Control System for Automatic Beverage Filling Machine

    Directory of Open Access Journals (Sweden)

    Yundan Lu

    2015-01-01

    Full Text Available Automatic filling system is the main equipment in the food machinery industry. With the development of beverage industry and increasing demand of the filling system. The relay control method in traditional Filling machine has low automation and integration level and cannot satisfy the rapid development of automatic production. PLC control method has advantages of simple programming, strong anti-interference and high working reliability, has gradually replace the relay control method. In this study, hardware and software for the automatic filling system based on PLC control is designed, especially the injection section servo control system which adopts the servo motor driver metering pump is carefully analyzed and the filling precision is highly improved.

  16. Automatic Generation Control Strategy Based on Balance of Daily Electric Energy

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    An automatic generation control strategy based on balance of daily total electric energy is put forward. It makes the balance between actual total generated energy controlled by automatic generation system and planned total energy on base of area control error, and makes the actual 24-hour active power load curve to approach the planned load curve. The generated energy is corrected by velocity weighting factor so that it conducts dynamic regulation and reaches the speed of response. Homologous strategy is used according to the real-time data in the operation of automatic generation control. Results of simulation are perfect and power energy compensation control with ideal effect can be achieved in the particular duration.

  17. Design and Implementation of Fuzzy Approximation PI Controller for Automatic Cruise Control System

    Directory of Open Access Journals (Sweden)

    Pallab Maji

    2015-01-01

    Full Text Available Fuzzy logic systems have been widely used for controlling nonlinear and complex dynamic systems by programming heuristic knowledge. But these systems are computationally complex and resource intensive. This paper presents a technique of development and porting of a fuzzy logic approximation PID controller (FLAC in an automatic cruise control (ACC system. ACC is a highly nonlinear process and its control is trivial due to the large change in parameters. Therefore, a suitable controller based on heuristic knowledge will be easy to develop and provide an effective solution. But the major problem with employing fuzzy logic controller (FLC is its complexity. Moreover, the designing of Rulebase requires efficient heuristic knowledge about the system which is rarely found. Therefore, in this paper, a novel rule extraction process is used to derive a FLAC. This controller is then ported on a C6748 DSP hardware with timing and memory optimization. Later, it is seamlessly connected to a network to support remote reconfigurability. A performance analysis is drawn based on processor-in loop test with Simulink model of a cruise control system for vehicle.

  18. Towards automatic model based controller design for reconfigurable plants

    DEFF Research Database (Denmark)

    Michelsen, Axel Gottlieb; Stoustrup, Jakob; Izadi-Zamanabadi, Roozbeh

    2008-01-01

    This paper introduces model-based Plug and Play Process Control, a novel concept for process control, which allows a model-based control system to be reconfigured when a sensor or an actuator is plugged into a controlled process. The work reported in this paper focuses on composing a monolithic m...

  19. AUTOMATIC CONTROL SYSTEM OF THE DRUM BOILER SUPERHEATED STEAM TEMPERATURE.

    Directory of Open Access Journals (Sweden)

    Juravliov A.A.

    2006-04-01

    Full Text Available The control system of the temperature of the superheated steam of the drum boiler is examined. Main features of the system are the PI-controller in the external control loop and introduction of the functional component of the error signal of the external control loop with the negative feedback of the error signal between the prescribed value of steam flowrate and the signal of the steam flowrate in the exit of the boiler in the internal control loop.

  20. ANALYSIS OF EXISTING AND PROSPECTIVE TECHNICAL CONTROL SYSTEMS OF NUMERIC CODES AUTOMATIC BLOCKING

    Directory of Open Access Journals (Sweden)

    A. M. Beznarytnyy

    2013-09-01

    Full Text Available Purpose. To identify the characteristic features of the engineering control measures system of automatic block of numeric code, identifying their advantages and disadvantages, to analyze the possibility of their use in the problems of diagnosing status of the devices automatic block and setting targets for the development of new diagnostic systems. Methodology. In order to achieve targets the objective theoretical and analytical method and the method of functional analysis have been used. Findings. The analysis of existing and future facilities of the remote control and diagnostics automatic block devices had shown that the existing systems of diagnosis were not sufficiently informative, designed primarily to control the discrete parameters, which in turn did not allow them to construct a decision support subsystem. In developing of new systems of technical diagnostics it was proposed to use the principle of centralized distributed processing of diagnostic data, to include a subsystem support decision-making in to the diagnostics system, it will reduce the amount of work to maintain the devices blocking and reduce recovery time after the occurrence injury. Originality. As a result, the currently existing engineering controls facilities of automatic block can not provide a full assessment of the state distillation alarms and locks. Criteria for the development of new systems of technical diagnostics with increasing amounts of diagnostic information and its automatic analysis were proposed. Practical value. These results of the analysis can be used in practice in order to select the technical control of automatic block devices, as well as the further development of diagnostic systems automatic block that allows for a gradual transition from a planned preventive maintenance service model to the actual state of the monitored devices.

  1. Shift Control System of Heavy-duty Vehicle Automatic Transmission

    Directory of Open Access Journals (Sweden)

    Yan Zhang

    2013-12-01

    Full Text Available Heavy-duty vehicle hydrodynamic mechanical automatic transmission shifting operation system was designed, mathematical model of its simplified hydraulic system was established and simulation model of shifting operation system was established with AMESim, the simulation experiment was carried out, then oil pressure curves of each clutch hydraulic cylinder were obtained when giving forward gear or reverse gear signals. The simulation results show that shifting operating system meets the design requirements, and verify the correctness of the model. The shift timing is correct, and there is no power interruption or gear overlap during the shift transition process. Joint oil pressure of designed system is stable, and shifting shock is small. The research results are providing the basis for further study of shifting operation system and a reasonable platform for the studying of shift schedule and quality. The theoretical design method and dynamic simulation experiment will be feasible for the real industrial applications. The research results can be used in design and optimization of hydraulic system

  2. Automatic power control for KMRR using reactivity constraint method

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byung I.; Kim, Myung H. [Kyunghee University, Yongin (Korea, Republic of)

    1990-07-01

    The use of reactivity constraint approach for the non-linear, digital controller is described. The design of controller was done for Korea Multipurpose Research Reactor(KMRR) which is now under construction. The performance test showed that reactivity constraint approach is a fast and reliable means for reactor power change control. A new formulation of the dynamic period equation for 2-point kinetics model is presented. The instantaneous dynamic period is calculated by new equation and used for time optimal control. A new controller keeping up the allowed minimum reactor period shows effective and reliable performance for power change.

  3. Method and apparatus for automatic control of a humanoid robot

    Science.gov (United States)

    Abdallah, Muhammad E (Inventor); Platt, Robert (Inventor); Wampler, II, Charles W. (Inventor); Reiland, Matthew J (Inventor); Sanders, Adam M (Inventor)

    2013-01-01

    A robotic system includes a humanoid robot having a plurality of joints adapted for force control with respect to an object acted upon by the robot, a graphical user interface (GUI) for receiving an input signal from a user, and a controller. The GUI provides the user with intuitive programming access to the controller. The controller controls the joints using an impedance-based control framework, which provides object level, end-effector level, and/or joint space-level control of the robot in response to the input signal. A method for controlling the robotic system includes receiving the input signal via the GUI, e.g., a desired force, and then processing the input signal using a host machine to control the joints via an impedance-based control framework. The framework provides object level, end-effector level, and/or joint space-level control of the robot, and allows for functional-based GUI to simplify implementation of a myriad of operating modes.

  4. 76 FR 50809 - Eleventh Meeting: RTCA Special Committee 220: Automatic Flight Guidance and Control

    Science.gov (United States)

    2011-08-16

    ... Federal Aviation Administration Eleventh Meeting: RTCA Special Committee 220: Automatic Flight Guidance... Control DATES: The meeting will be held September 13-15, 2011, from 9 a.m. to 5 p.m., unless stated... Guidance and Control Agenda Tuesday September 13--Thursday, September 15, 2011 Tuesday, September...

  5. The Development of Automatic and Controlled Inhibitory Retrieval Processes in True and False Recall

    Science.gov (United States)

    Knott, Lauren M.; Howe, Mark L.; Wimmer, Marina C.; Dewhurst, Stephen A.

    2011-01-01

    In three experiments, we investigated the role of automatic and controlled inhibitory retrieval processes in true and false memory development in children and adults. Experiment 1 incorporated a directed forgetting task to examine controlled retrieval inhibition. Experiments 2 and 3 used a part-set cue and retrieval practice task to examine…

  6. Eye movements in pedophiles: automatic and controlled attentional processes while viewing prepubescent stimuli.

    Science.gov (United States)

    Fromberger, Peter; Jordan, Kirsten; Steinkrauss, Henrike; von Herder, Jakob; Stolpmann, Georg; Kröner-Herwig, Birgit; Müller, Jürgen Leo

    2013-05-01

    Recent theories in sexuality highlight the importance of automatic and controlled attentional processes in viewing sexually relevant stimuli. The model of Spiering and Everaerd (2007) assumes that sexually relevant features of a stimulus are preattentively selected and automatically induce focal attention to these sexually relevant aspects. Whether this assumption proves true for pedophiles is unknown. It is aim of this study to test this assumption empirically for people suffering from pedophilic interests. Twenty-two pedophiles, 8 nonpedophilic forensic controls, and 52 healthy controls simultaneously viewed the picture of a child and the picture of an adult while eye movements were measured. Entry time was assessed as a measure of automatic attentional processes and relative fixation time in order to assess controlled attentional processes. Pedophiles demonstrated significantly shorter entry time to child stimuli than to adult stimuli. The opposite was the case for nonpedophiles, as they showed longer relative fixation time for adult stimuli, and, against all expectations, pedophiles also demonstrated longer relative fixation time for adult stimuli. The results confirmed the hypothesis that pedophiles automatically selected sexually relevant stimuli (children). Contrary to all expectations, this automatic selection did not trigger the focal attention to these sexually relevant pictures. Furthermore, pedophiles were first and longest attracted by faces and pubic regions of children; nonpedophiles were first and longest attracted by faces and breasts of adults. The results demonstrated, for the first time, that the face and pubic region are the most attracting regions in children for pedophiles. PMID:23206281

  7. Realization of the ergonomics design and automatic control of the fundus cameras

    Science.gov (United States)

    Zeng, Chi-liang; Xiao, Ze-xin; Deng, Shi-chao; Yu, Xin-ye

    2012-12-01

    The principles of ergonomics design in fundus cameras should be extending the agreeableness by automatic control. Firstly, a 3D positional numerical control system is designed for positioning the eye pupils of the patients who are doing fundus examinations. This system consists of a electronically controlled chin bracket for moving up and down, a lateral movement of binocular with the detector and the automatic refocusing of the edges of the eye pupils. Secondly, an auto-focusing device for the object plane of patient's fundus is designed, which collects the patient's fundus images automatically whether their eyes is ametropic or not. Finally, a moving visual target is developed for expanding the fields of the fundus images.

  8. Methodology of automatic quality control of aluminium castings

    Directory of Open Access Journals (Sweden)

    J.H. Sokolowski

    2007-01-01

    Full Text Available Purpose: Employment of the artificial intelligence tools for development of the methodology of the automatedassessment of quality and structural defects in the Al and Mg alloys and the custom made computer softwarewill make it possible to determine the quality of the manufactured element based on the digital images registeredin the X-ray flaw detection examinations. The possibility to correlate the frequency and morphology of defectswith the technological process parameters will make it also possible to identify and classify these defects andcontrol the process to minimise and eliminate them.Design/methodology/approach: The developed design methodologies both the material and technologicalones will make it possible to improve shortly the quality of materials from the light alloys in the technologicalprocess, and the automatic process flow correction will make the production cost reduction possible, and - firstof all - to reduce the amount of the waste products.Findings: The merit of the project consists in the interdisciplinary joining of the knowledge in the area oflight metal alloys, including Al and/or Mg, in the area of materials processing connected with the entire scopeof problems connected with manufacturing of products and their elements, in the area of the automated lowpressuredie casting, and also in the methodology of structure and properties assessment of the engineeringmaterials with, among others, the X-ray flaw detection and computer image analysis methods.Practical implications: The developed methodology of the automated assessment of quality and properties ofthe light Al and Mg based alloys may be used by manufacturers of subassemblies and elements of engines (e.g.,car engine bodies made from the light alloys with the low-pressure casting in the sand moulds.Originality/value: The project’s effects will be shortening the time needed for analyses and elimination of manusubjective evaluation errors made by humans.

  9. Adaptive Clutch Engaging Process Control for Automatic Mechanical Transmission

    Institute of Scientific and Technical Information of China (English)

    LIU Hai-ou; CHEN Hui-yan; DING Hua-rong; HE Zhong-bo

    2005-01-01

    Based on detail analysis of clutch engaging process control targets and adaptive demands, a control strategy which is based on speed signal, different from that of based on main clutch displacement signal, is put forward. It considers both jerk and slipping work which are the most commonly used quality evaluating indexes of vehicle starting phase. The adaptive control system and its reference model are discussed profoundly.Taking the adaptability to different starting gears and different road conditions as examples, some proving field test records are shown to illustrate the main clutch adaptive control strategy at starting phase. Proving field test gives acceptable results.

  10. Hybrid Control of a Two-Wheeled Automatic-Balancing Robot with Backlash Feature

    DEFF Research Database (Denmark)

    Løhndorf, Petar Durdevic; Yang, Zhenyu

    2013-01-01

    This paper investigates the application of hybrid control for an automatic balancing robot system subject to backlash effect. The developed controller is a type of sliding mode controller, refereed to as a switching controller, with respect to different situations i.e., whether the backlash is pr...... and comparisons with other solutions show the proposed solution can lead to a very satisfactory anti-backlash performance, with an easy and cost-effective implementation....

  11. Design and Implementation of Automatic Air Flow Rate Control System

    Science.gov (United States)

    Akbar, A.; Saputra, C.; Munir, M. M.; Khairurrijal

    2016-08-01

    Venturimeter is an apparatus that can be used to measure the air flow rate. In this experiment we designed a venturimeter which equipped with a valve that is used to control the air flow rate. The difference of pressure between the cross sections was measured with the differential pressure sensor GA 100-015WD which can calculate the difference of pressures from 0 to 3737.33 Pa. A 42M048C Z36 stepper motor was used to control the valve. The precision of this motor rotation is about 0.15 °. A Graphical User Interface (GUI) was developed to monitor and set the value of flow rate then an 8-bit microcontroller was used to process the control system In this experiment- the venturimeter has been examined to get the optimal parameter of controller. The results show that the controller can set the stable output air flow rate.

  12. Improvement of remote control system of automatic ultrasonic equipment for inspection of reactor pressure vessel

    International Nuclear Information System (INIS)

    One of the important issues related to the nuclear safety is in-service inspection of reactor pressure vessel (RPV). A remote controlled automatic ultrasonic method is applied to the inspection. At present the automatic ultrasonic inspection system owned by KAERI is interrupted due to degradation of parts. In order to resume field inspection new remote control system for the equipment was designed and installed to the existing equipment. New ultrasonic sensors and their modules for RPV inspection were designed and fabricated in accordance with the new requirements of the inspection codes. Ultrasonic sensors were verified for the use in the RPV inspection. (author)

  13. Improvement of remote control system of automatic ultrasonic equipment for inspection of reactor pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Cheong, Yong Moo; Jung, H. K.; Joo, Y. S.; Koo, K. M.; Hyung, H.; Sim, C. M.; Gong, U. S.; Kim, S. H.; Lee, J. P.; Rhoo, H. C.; Kim, M. S.; Ryoo, S. K.; Choi, C. H.; Oh, K. I

    1999-12-01

    One of the important issues related to the nuclear safety is in-service inspection of reactor pressure vessel (RPV). A remote controlled automatic ultrasonic method is applied to the inspection. At present the automatic ultrasonic inspection system owned by KAERI is interrupted due to degradation of parts. In order to resume field inspection new remote control system for the equipment was designed and installed to the existing equipment. New ultrasonic sensors and their modules for RPV inspection were designed and fabricated in accordance with the new requirements of the inspection codes. Ultrasonic sensors were verified for the use in the RPV inspection. (autho0008.

  14. Automatic Control of Contextual Interaction Integrated with Affection and Architectural Attentional Control

    Directory of Open Access Journals (Sweden)

    Yanrong Jiang

    2013-03-01

    Full Text Available It is still a challenge for robots to interact with complex environments in a smooth and natural manner. The robot should be aware of its surroundings and inner status to make decisions accordingly and appropriately. Contexts benefit the interaction a lot, such as avoiding frequent interruptions (e.g., the explicit inputting requests and thus are essential for interaction. Other challenges, such as shifting attentional focus to a more important stimulus, etc., are also crucial in interaction control. This paper presents a hybrid automatic control approach for interaction, as well as its integration, with these multiple important factors, aiming at performing natural, human‐like interactions in robots. In particular, a novel approach of architectural attentional control, based on affection is presented, which attempts to shift the attentional focus in a natural manner. Context‐aware computing is combined with interaction to endow the robot with proactive abilities. The long‐term interaction control approaches are described. Emotion and personality are introduced into the interaction and their influence mechanism on interaction is explored. We implemented the proposal in an interactive head robot (IHR and the experimental results indicate the effectiveness.

  15. Development of Full Automatic Flash Butt Welding with Digital Control

    Institute of Scientific and Technical Information of China (English)

    WANG Rui; SUN Hexu; WANG Hongwen

    2006-01-01

    The hardware and software design of two digital control systems based on 80C196KB MCU for flash butt welder is introduced in this paper. The welding power supply is made of six-phase half-wave rectifier. The welding outer characteristic of welding machine is realized by digital PI algorithm with the voltage close-loop feedback. The flashing curve is finished by electric-hydraulic servo valve .The process control system transfers datum with power supply system by a serial communication interface. The parameters of the control systems are collected by photoelectrical seclusion to avoid the disturbing of the electromagnetism in welding process.

  16. Automatic method of measuring silicon-controlled-rectifier holding current

    Science.gov (United States)

    Maslowski, E. A.

    1972-01-01

    Development of automated silicon controlled rectifier circuit for measuring minimum anode current required to maintain rectifiers in conducting state is discussed. Components of circuit are described and principles of operation are explained. Illustration of circuit is provided.

  17. Research on HCI Prototype Design of Ink Automatic Control System for Offset Printer

    Institute of Scientific and Technical Information of China (English)

    ZHANG Jianyu; GAO Lixin; CUI Lingli; WANG Yingwang; LI Xianghui

    2006-01-01

    In order to solve the low efficiency and poor precision problems of traditional ink control methods on domestic offset printers, developing modern ink automatic control system has become more and more urgent. As an important subsystem, the human computer interface (HCI) is a key function for the wholly automatic control. Once this goal is obtained, all the printing procedures especially the automatic control of ink volume should be finished with human computer interface in different areas. Considering the HCI design theory and structure characteristics of domestic printers comprehensively, the HCI prototype for automatic ink control system has been developed based on Visual Basic platform. As the individual ink key is instead of the integrated key, the division result of ink fountain can be displayed on the interface. Through the interface, the dynamic adjusting functions such as modifying ink volume, locking or unlocking each ink key and real-time displaying the adjusting results etc. can be completed. The simulation test has shown that the opening and practical feature of the prototype is satisfactory.

  18. SOME PROBLEMS OF AUTOMATIC CONTROL OF DEFECTS OF GLASSWORKS

    Directory of Open Access Journals (Sweden)

    Rozhkov S.A.

    2006-04-01

    Full Text Available It is performed analysis of existing systems for checking a quality of glass products with reference to problems of automation of checking of quality of finished products. There are brought results of experimental studies of the model of the system for quality control with the optical sensor.

  19. Radioisotope gage for automatic control of cotton wool package

    International Nuclear Information System (INIS)

    A summary is given of research work and in-service tests carried out on radiometric gages for on-line control in bandage industry. A special type of thickness gage based on beta absorption measurements restricts the weight fluctuations of ready cotton wool packages to less than +- 2 per cent. Economic effectiveness of the gage is evaluated

  20. Automatic control of cycling effort using electric bicycles and mobile devices

    OpenAIRE

    Jose A. Afonso; Rodrigues, Filipe J.; Delfim Pedrosa; Joao L. Afonso

    2015-01-01

    This paper describes the development and evaluation of a novel effort control system for cycling, which contributes to promote the users’ mobility and physical health. This system provides automatic control of the motor assistance level of an electric bicycle in order to ensure that the cyclist’s effort remains inside the desired target zone, regardless of changes in other variables which normally affect the effort, such as the slope of the road. The system presented in this paper controls th...

  1. Automatic Frequency Controller for Power Amplifiers Used in Bio-Implanted Applications: Issues and Challenges

    Directory of Open Access Journals (Sweden)

    Mahammad A. Hannan

    2014-12-01

    Full Text Available With the development of communication technologies, the use of wireless systems in biomedical implanted devices has become very useful. Bio-implantable devices are electronic devices which are used for treatment and monitoring brain implants, pacemakers, cochlear implants, retinal implants and so on. The inductive coupling link is used to transmit power and data between the primary and secondary sides of the biomedical implanted system, in which efficient power amplifier is very much needed to ensure the best data transmission rates and low power losses. However, the efficiency of the implanted devices depends on the circuit design, controller, load variation, changes of radio frequency coil’s mutual displacement and coupling coefficients. This paper provides a comprehensive survey on various power amplifier classes and their characteristics, efficiency and controller techniques that have been used in bio-implants. The automatic frequency controller used in biomedical implants such as gate drive switching control, closed loop power control, voltage controlled oscillator, capacitor control and microcontroller frequency control have been explained. Most of these techniques keep the resonance frequency stable in transcutaneous power transfer between the external coil and the coil implanted inside the body. Detailed information including carrier frequency, power efficiency, coils displacement, power consumption, supplied voltage and CMOS chip for the controllers techniques are investigated and summarized in the provided tables. From the rigorous review, it is observed that the existing automatic frequency controller technologies are more or less can capable of performing well in the implant devices; however, the systems are still not up to the mark. Accordingly, current challenges and problems of the typical automatic frequency controller techniques for power amplifiers are illustrated, with a brief suggestions and discussion section concerning

  2. A software architecture for hard real-time execution of automatically synthesized plans or control laws

    Science.gov (United States)

    Schoppers, Marcel

    1994-01-01

    The design of a flexible, real-time software architecture for trajectory planning and automatic control of redundant manipulators is described. Emphasis is placed on a technique of designing control systems that are both flexible and robust yet have good real-time performance. The solution presented involves an artificial intelligence algorithm that dynamically reprograms the real-time control system while planning system behavior.

  3. Programmable Logic Controllers for Systems of Automatic of the Level Crossing

    Directory of Open Access Journals (Sweden)

    Mieczyslaw Kornaszewski

    2006-01-01

    Full Text Available The railway crossings are vulnerable to incidence of high number of accidents often deadly. In order to face this problem, the modern systems of automatic of the level crossing have been introduced. These systems are based on Programmable Logic Controllers, which allow the designers to exploit self-control mechanisms, events acquiring, technical diagnostic which in turn enable remote control and acquisition of faults.

  4. daptive Filter Used as a Dynamic Compensator in Automatic Gauge Control of Strip Rolling Processes

    Directory of Open Access Journals (Sweden)

    N. ROMAN

    2010-12-01

    Full Text Available The paper deals with a control structure of the strip thickness in a rolling mill of quarto type (AGC – Automatic Gauge Control. It performs two functions: the compensation of errors induced by unideal dynamics of the tracking systems lead by AGC system and the control adaptation to the change of dynamic properties of the tracking systems. The compensation of dynamical errors is achieved through inverse models of the tracking system, implemented as adaptive filters.

  5. Adaptive Automatic Gauge Control of a Cold Strip Rolling Process

    Directory of Open Access Journals (Sweden)

    ROMAN, N.

    2010-02-01

    Full Text Available The paper tackles with thickness control structure of the cold rolled strips. This structure is based on the rolls position control of a reversible quarto rolling mill. The main feature of the system proposed in the paper consists in the compensation of the errors introduced by the deficient dynamics of the hydraulic servo-system used for the rolls positioning, by means of a dynamic compensator that approximates the inverse system of the servo-system. Because the servo-system is considered variant over time, an on-line identification of the servo-system and parameter adapting of the compensator are achieved. The results obtained by numerical simulation are presented together with the data taken from real process. These results illustrate the efficiency of the proposed solutions.

  6. Automatic Voltage Control (AVC) of Danish Transmission System - Concept design

    DEFF Research Database (Denmark)

    Qin, Nan; Abildgaard, Hans; Lund, P.;

    2014-01-01

    . Another consequence is the public way of generally thinking green which have led to a national decision of undergrounding not only all of the Danish distribution system but also the future transmission system. These issues initiate the infrastructure constructions of the transmission system i.e. a large...... amount of overhead lines over 100 kV as well as the new planed transmission lines will be undergrounded; the transfer capacities will be enlarged by upgrading the interconnections. Large amounts of reactive power components will be placed in the system partly for cable compensation and partly for voltage...... the substation loses the telecommunications to the control center. RPCs will be integrated to the AVC system as normative regulators in the later stage. Distributed generation units can be organized as virtual power plants and participate in voltage control at transmission level. Energinet.dk as the Danish TSO...

  7. Automatic washing of hooves can help control digital dermatitis in dairy cows

    DEFF Research Database (Denmark)

    Thomsen, Peter Thorup; Kjær Ersbøll, Annette; Sørensen, Jan Tind

    2012-01-01

    in 6 commercial dairy herds in 2 experiments (1 and 2). In the experimental herd, automatic hoof washing resulted in cleaner hooves. In experiments 1 and 2, cows were washed after each milking on the left side only, leaving the right side unwashed as a within-cow control. In experiment 1, hooves were...

  8. Using Automatic Code Generation in the Attitude Control Flight Software Engineering Process

    Science.gov (United States)

    McComas, David; O'Donnell, James R., Jr.; Andrews, Stephen F.

    1999-01-01

    This paper presents an overview of the attitude control subsystem flight software development process, identifies how the process has changed due to automatic code generation, analyzes each software development phase in detail, and concludes with a summary of our lessons learned.

  9. Working out of video lessons to improve the quality of automatic control theory

    OpenAIRE

    Усик, Виктория Валерьевна; Пономарева, Анна Викторовна; Костюк, Александр Николаевич; Крапивницкая, Виктория Евгеньевна; Максимов, Владислав Александрович

    2010-01-01

    In article modern approaches to distance learning are stated. The characteristic, structural components and problems of performance of practical problems are considered in distance learning. The example of creation of video tutorial is led to a laboratory course «The automatic control theory» in program Adobe Captivate.

  10. Matching Automatic Gain Control Across Devices in Bimodal Cochlear Implant Users

    NARCIS (Netherlands)

    Veugen, L.C.E.; Chalupper, J.; Snik, A.F.M; Opstal, A.J. van; Mens, L.H.M

    2016-01-01

    OBJECTIVES: The purpose of this study was to improve bimodal benefit in listeners using a cochlear implant (CI) and a hearing aid (HA) in contralateral ears, by matching the time constants and the number of compression channels of the automatic gain control (AGC) of the HA to the CI. Equivalent AGC

  11. Postural Control and Automaticity in Dyslexic Children: The Relationship between Visual Information and Body Sway

    Science.gov (United States)

    Barela, Jose A.; Dias, Josenaldo L.; Godoi, Daniela; Viana, Andre R.; de Freitas, Paulo B.

    2011-01-01

    Difficulty with literacy acquisition is only one of the symptoms of developmental dyslexia. Dyslexic children also show poor motor coordination and postural control. Those problems could be associated with automaticity, i.e., difficulty in performing a task without dispending a fair amount of conscious efforts. If this is the case, dyslexic…

  12. On the question of the necessity of implementation of automatic control systems in timber industry

    Science.gov (United States)

    Khasanov, E. R.; Zelenkov, P. V.; Petrosyan, M. O.; Murygin, A. V.; Laptenor, V. D.

    2016-04-01

    The paper considers the necessity of implementation of automatic control systems on the level of forest farms management and timber industry. Main areas of activity, which currently subjected to automation, are revealed. Objectives, which solved by implementation of APCS, are identified.

  13. Remote automatic control scheme for plasma arc cutting of contaminated waste

    International Nuclear Information System (INIS)

    The Robotics Development Group at the Savannah River Technology Center has developed and implemented a scheme to perform automatic cutting of metallic contaminated waste. The scheme employs a plasma arc cutter in conjunction with a laser ranging sensor attached to a robotic manipulator called the Telerobot. A software algorithm using proportional control is then used to perturb the robot's trajectory in such a way as to regulate the plasma arc standoff and the robot's speed in order to achieve automatic plasma arc cuts. The scheme has been successfully tested on simulated waste materials and the results have been very favorable. This report details the development and testing of the scheme

  14. Optimization of Automatic Train Control for Energy Management and Service Reliability

    Energy Technology Data Exchange (ETDEWEB)

    Susanna P. Gordon; Richard M. Wheeler; Timothy J. Sa; Donald A. Sheaffer

    1999-11-01

    A new generation of automatic train control systems is currently under development in the commuter-rail transit industry. These systems will utilize radio communication between wayside control computers and trains in order to provide high precision train control beyond the capability of today's automatic systems. The Bay Area Rapid Transit (BART) system is developing such a modern control system in collaboration with Harmon Industries. This system, called the Advanced Automatic Train Control (AATC) system, will allow for precision train locating and control, and will facilitate coordination of the trajectories of multiple trains. This system will be capable of running trains more closely together and decreasing the time a train requires to traverse the system, while simultaneously operating with a more modest traction power infrastructure, and providing a smoother, more comfortable ride to commuters. The authors have collaborated with BART to develop a simulator of the AATC system and the traction power system, and they have utilized this simulator as a testbed for the development of advanced train control techniques. Several train control algorithms, including one employing a neural network for train voltage prediction, have been developed and tested in the simulator. Smoother train trajectories, reduced power infrastructure requirements, and reduced energy consumption have been demonstrated. Improved service reliability is also expected to result.

  15. Unattended vehicle detection for automatic traffic light control

    Science.gov (United States)

    Abdel Hady, Aya Salama; Moustafa, Mohamed

    2013-12-01

    Machine vision based traffic light control depends mainly on measuring traffic statistics at cross roads. Most of the previous studies have not taken unattended vehicles into consideration when calculating either the traffic density or the traffic flow. In this paper, we propose incorporating unattended vehicles into a new metric for measuring the traffic congestion. In addition to the vehicle motion analysis, opening the driver's side door is an important indicator that this vehicle is going to be unattended. Therefore, we focus in this paper on presenting how to detect this event for stationary vehicles from a live camera or a video feed. Through a set of experiments, we have found out that a Scale Invariant Feature Transform (SIFT) feature-descriptor with a Support Vector Machines (SVM) classifier was able to successfully classify open-door vehicles from closed-door ones in 96.7% of our test dataset.

  16. Automatic control system for measuring currents produced by ionization chambers

    International Nuclear Information System (INIS)

    Ionization Chambers in current mode operation are usually used in Nuclear Metrology. Activity measurements are quickly performed by Ionization Chambers, with very good precision. For this purpose measurements of very low ionization currents, carried out by high quality instrumentation, are required. Usually, electrometers perform the current integration method under command of signals from an automation system, in order to reduce the measurement uncertainties. Among the measurement systems at the Laboratorio de Metrologia Nuclear (LMN) of IPEN, there are two ionization chamber systems. In the present work, an automation system developed for current integration measurements is described. This automation system is composed by software (graphic interface and control) and an electronic module connected to a microcomputer, by means of a commercial data acquisition card. Several test measurements were performed in order to determine the intrinsic uncertainty, linearity and stability of the system. Using calibrated radioactive solutions, the IG12/A20 chamber calibration factors for 18F and 153Sm were obtained, making possible to determine activities of these radionuclides. (author)

  17. Automatic control system of the radiometric system for inspection of large-scale vehicles and cargoes

    International Nuclear Information System (INIS)

    The automatic control system (ACS) is intended to control the equipment of the radiometric inspection system in the normal operating modes as well as during the preventive maintenance, maintenance/repair and adjustment works; for acquisition of the data on the status of the equipment, reliable protection of the personnel and equipment, acquisition, storage and processing of the results of operation and to ensure service maintenance.

  18. Possibilities for automatic control of hydro-mechanical transmission and birotating electric machine

    OpenAIRE

    Mikhailov, V.V.; A. G. Snitkov

    2014-01-01

    The paper presents mathematical models and results of virtual investigations pertaining to the selected motion parameters of a mobile machine equipped with hydro mechanical and modernized transmissions. The machine has been tested in similar technological cycles and it has been equipped with a universal automatic control system. Changes in structure and type of power transmission have been obtained with the help of a control algorithm including an extra reversible electric machine which is sw...

  19. Further Flight Tests on the Effectiveness of Handley Page Automatic Control Slots

    Science.gov (United States)

    Pleines, Wilhelm

    1932-01-01

    Investigation of damping in roll within range of maximum lift with the Albatross L 75, with and without Handley Page automatic control slots, revealed the following: Without control slots, any attempt to go beyond a certain angle of attack near c(sub a max) in glide and climb, is followed by sudden sideslip. The conduct of the airplane throughout the motions in roll, moreover, confirmed that all attempts to higher angles of attack are accompanied by sudden loss of damping in roll.

  20. Short communication: Automatic washing of hooves can help control digital dermatitis in dairy cows.

    Science.gov (United States)

    Thomsen, Peter T; Ersbøll, Annette Kjær; Sørensen, Jan Tind

    2012-12-01

    The objectives of this study were to develop and test a system for automatic washing of the hooves of dairy cows and to evaluate the effect of frequent automatic washing on the prevalence of digital dermatitis (DD). An automatic hoof washer was developed in an experimental dairy herd and tested in 6 commercial dairy herds in 2 experiments (1 and 2). In the experimental herd, automatic hoof washing resulted in cleaner hooves. In experiments 1 and 2, cows were washed after each milking on the left side only, leaving the right side unwashed as a within-cow control. In experiment 1, hooves were washed with a water and 0.4% soap solution. In experiment 2, hooves were washed with water only. In each experiment, DD was scored in a hoof-trimming chute approximately 60 d after the start of hoof washing. Data were analyzed using a generalized linear mixed model. The outcome was the DD status of each leg (DD positive or DD negative). Herd and cow within herd were included as random effects, and treatment (washing or control) was included as a fixed effect. The statistical analyses showed that the odds ratio of having DD was 1.48 in the control leg compared with the washed leg in experiment 1. In experiment 2, the odds ratio of having DD was 1.27 in the control leg compared with the washed leg. We concluded that automatic washing of hooves with water and soap can help decrease the prevalence of DD in commercial dairy herds.

  1. Automatic Gauge Control in Rolling Process Based on Multiple Smith Predictor Models

    Directory of Open Access Journals (Sweden)

    Jiangyun Li

    2014-01-01

    Full Text Available Automatic rolling process is a high-speed system which always requires high-speed control and communication capabilities. Meanwhile, it is also a typical complex electromechanical system; distributed control has become the mainstream of computer control system for rolling mill. Generally, the control system adopts the 2-level control structure—basic automation (Level 1 and process control (Level 2—to achieve the automatic gauge control. In Level 1, there is always a certain distance between the roll gap of each stand and the thickness testing point, leading to the time delay of gauge control. Smith predictor is a method to cope with time-delay system, but the practical feedback control based on traditional Smith predictor cannot get the ideal control result, because the time delay is hard to be measured precisely and in some situations it may vary in a certain range. In this paper, based on adaptive Smith predictor, we employ multiple models to cover the uncertainties of time delay. The optimal model will be selected by the proposed switch mechanism. Simulations show that the proposed multiple Smith model method exhibits excellent performance in improving the control result even for system with jumping time delay.

  2. Monitor automatic gauge control strategy with a Smith predictor for steel strip rolling

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    The simplified transfer function diagram block for a monitor automatic gauge control (Mon-AGC) system of strip steel rolling process was investigated.The new notion of strip sample length was given.In this way,the delay time varying with the rolling speed was evaded.After a Smith predictor was used to monitor the AGC system,the control laws were deduced for both proportional and integral regulators.The control strategies showed that by choosing the controller parameter P=∞ for both control algorithms each regulator could compensate the whole strip gage error in the first control step.The result shows that the integral algorithm is more controllable for the system regulating process and has a better steady-state precision than the proportional regulator.Compared with the traditional control strategy,the new control laws have a faster response speed and a higher steady-state precision.

  3. Design of a modern automatic control system for the activated sludge process in wastewater treatment

    Institute of Scientific and Technical Information of China (English)

    Alexandros D. Kotzapetros; Panayotis A. Paraskevas; Athanasios S. Stasinakis

    2015-01-01

    The Activated Sludge Process (ASP) exhibits highly nonlinear properties. The design of an automatic control system that is robust against disturbance of inlet wastewater flow rate and has short process settling times is a chal enging matter. The proposed control method is an I-P modified controller automatic control system with state variable feedback and control canonical form simulation diagram for the process. A more stable response is achieved with this type of modern control. Settling times of 0.48 days are achieved for the concentration of microorganisms, (reference value step increase of 50 mg·L−1) and 0.01 days for the concentration of oxygen (reference value step increase of 0.1 mg·L−1). Fluctuations of concentrations of oxygen and microorganisms after an inlet disturbance of 5 × 103m3·d−1 are smal . Changes in the reference values of oxygen and microorganisms (increases by 10%, 20%and 30%) show satisfactory response of the system in al cases. Changes in the value of inlet wastewater flow rate disturbance (increases by 10%, 25%, 50%and 100%) are stabilized by the control system in short time. Maximum percent overshoot is also taken in consideration in all cases and the largest value is 25%which is acceptable. The proposed method with I-P controller is better for disturbance rejection and process settling times compared to the same method using PI control er. This method can substitute optimal control systems in ASP.

  4. Results of automatic system implementation for the friction control rods execution in Cofrentes nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Palomo, M., E-mail: mpalomo@iqn.upv.es [Universidad Politecnica de Valencia (UPV) (Spain); Urrea, M., E-mail: matias.urrea@iberdrola.es [Iberdrola Generacion S.A. Valencia (Spain). C.N. Cofrentes; Curiel, M., E-mail: m.curiel@lainsa.com [Logistica y Acondicionamientos Industriales (LAINSA), Valencia (Spain); Arnaldos, A., E-mail: a.arnaldos@titaniast.com [TITANIA Servicios Teconologicos, Valencia (Spain)

    2011-07-01

    The purpose of this presentation is to show the obtained results in Cofrentes Nuclear Power Plant (Spain) of Control Rods PCC/24 Friction Test Procedure. In order to perform this, a Control Rod Friction Test System has been developed. Principally, this system consists on software and data acquisition hardware that obtains and analyzes the control rod pressure variation on which the test is being made. The PCC/24 Procedure objective is to detect an excessive friction in the control rod movement that could cause a CRD (Control Rod Drive) movement slower than usual. This test is necessary every time that an anomalous alteration is produced in the reactor core that could affect to a fuel rod, and it is executed before the time measure of control rods rapid scram test of the affected rods. This test has to be carried out to all the reactor control rods and takes valuable time during plant refuelling. So, by means of an automatic system to perform the test, we obtain an important time saving during refuelling. On the other hand, the on-line monitoring of the control rod insertion and changes in differential pressure, permits a control rod operation fast and safe validation. Moreover, an automatic individual report of every rod is generated by the system and a final global result report of the entire test developed in refuelling is generated. The mentioned reports can be attached directly to the procedure documents obtaining an office data processing important saving time.(author)

  5. Results of automatic system implementation for the friction control rods execution in Cofrentes nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Curiel, M. [Logistica y Acondicionamientos Industriales SAU, Sorolla Center, local 10, Av. de las Cortes Valencianas, 46015 Valencia (Spain); Palomo, M. J. [ISIRYM, Universidad Politecnica de Valencia, Camino de Vera s/n, Valencia (Spain); Urrea, M. [Iberdrola Generacion S. A., Central Nuclear Cofrentes, Carretera Almansa Requena s/n, 04662 Cofrentes, Valencia (Spain); Arnaldos, A., E-mail: m.curiel@lainsa.co [TITANIA Servicios Tecnologicos SL, Sorolla Center, local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain)

    2010-10-15

    The purpose of this presentation is to show the obtained results in Cofrentes nuclear power plant (Spain) of control rods Pcc/24 friction test procedure. In order to perform this, a control rod friction test system has been developed. Principally, this system consists on software and data acquisition hardware that obtains and analyzes the control rod pressure variation on which the test is being made. The Pcc/24 procedure objective is to detect an excessive friction in the control rod movement that could cause a control rod drive movement slower than usual. This test is necessary every time that an anomalous alteration is produced in the reactor core that could affect to a fuel rod, and it is executed before the time measure of control rods rapid scram test of the affected rods. This test has to be carried out to all the reactor control rods and takes valuable time during plant refuelling. So, by means of an automatic system to perform the test, we obtain an important time saving during refuelling. On the other hand, the on-line monitoring of the control rod insertion and changes in differential pressure, permits a control rod operation fast and safe validation. Moreover, an automatic individual report of every rod is generated by the system and a final global result report of the entire test developed in refuelling is generated. The mentioned reports can be attached directly to the procedure documents obtaining an office data processing important saving time. (Author)

  6. Automatic Learning of Fine Operating Rules for Online Power System Security Control.

    Science.gov (United States)

    Sun, Hongbin; Zhao, Feng; Wang, Hao; Wang, Kang; Jiang, Weiyong; Guo, Qinglai; Zhang, Boming; Wehenkel, Louis

    2016-08-01

    Fine operating rules for security control and an automatic system for their online discovery were developed to adapt to the development of smart grids. The automatic system uses the real-time system state to determine critical flowgates, and then a continuation power flow-based security analysis is used to compute the initial transfer capability of critical flowgates. Next, the system applies the Monte Carlo simulations to expected short-term operating condition changes, feature selection, and a linear least squares fitting of the fine operating rules. The proposed system was validated both on an academic test system and on a provincial power system in China. The results indicated that the derived rules provide accuracy and good interpretability and are suitable for real-time power system security control. The use of high-performance computing systems enables these fine operating rules to be refreshed online every 15 min. PMID:25680217

  7. Automatic module system for control of an ion source 'Cryon-S'

    International Nuclear Information System (INIS)

    The automatic module system for control of an ionizer 'Cryon-S' using fiber optics links and PC/XT is described. Brief technical characteristics of basic and service optical systems used in the first run for acceleration of nuclei sulfur on the synchrophasotron of the Laboratory of High Energies (L.H.E.) from the electron beam ion source 'Cryon-S' are presented. 26 refs.; 5 figs

  8. Automatic quality control system of the installed straws into TRT wheels

    International Nuclear Information System (INIS)

    An automatic quality control system of the installed straws into TRT ATLAS is described. The system provides straw testing for straightness and electrical isolation of the straws during their installation. Testing of the quality of installation of each straw takes 9 s, and the test of one layer of the straws - about 2 hours. The application of this system provides an opportunity of correcting defects in due time, which can influence the detector operation in the future

  9. Bayesian Updating in the EEG : Differentiation between Automatic and Controlled Processes of Human Economic Decision Making

    OpenAIRE

    Hügelschäfer, Sabine

    2011-01-01

    Research has shown that economic decision makers often do not behave according to the prescriptions of rationality, but instead show systematic deviations from rational behavior (e.g., Starmer, 2000). One approach to explain these deviations is taking a dual-process perspective (see Evans, 2008; Sanfey & Chang, 2008; Weber & Johnson, 2009) in which a distinction is made between deliberate, resource-consuming controlled processes and fast, effortless automatic processes. In many cases, deviati...

  10. An automatically controlled system for waste transport in low level nuclear waste storage facilities

    International Nuclear Information System (INIS)

    Kobe Steel has developed and manufactured a fully automatic remote-controlled system for the storage of up to 42 000 waste drum packages discharged from nuclear reprocessing facilities. The system includes two forklifts and an elevator both of which are controlled via a remote control center. The forklifts can transport up to 4 ton waste packages. The elevator can transport a forklift carrying a maximum weight package. The system also includes a rescue vehicle that can be manually operated at a distance from a remote station using ITV cameras. (author)

  11. System design of the METC automatic data acquisition and control system

    Energy Technology Data Exchange (ETDEWEB)

    Goff, D. R.; Armstrong, D. L.

    1982-02-01

    A system of computer programs and hardware was developed by the Instrumentation Branch of the Morgantown Energy Technology Center (METC) to provide data acquisition and control features for research projects at the site. The Automatic Data Acquisition and Control System (ADACS) has the capability of servicing up to eight individual projects simultaneously, providing data acquisition, data feedback, and process control where needed. Several novel software features - including a data table driven program, extensive feedback in real time, free format English commands, and high reliability - were incorporated to provide these functions.

  12. DISTURBANCE ERROR INVARIANCE IN AUTOMATIC CONTROL SYSTEMS FOR TECHNOLOGICAL OBJECT TRAJECTORY MOVEMENT

    Directory of Open Access Journals (Sweden)

    A. V. Lekareva

    2016-09-01

    Full Text Available We consider combined control in automatic control systems for technological objects trajectory movements. We present research results of the system disturbance invariance ensuring on the example of the technological manipulator that implements hydrocutting of the oil pipelines. Control is based on the propositions of the fourth modified invariance form with the use of bootstrapping methods. The paper presents analysis of results obtained by two different correction methods. The essence of the first method lies in injection of additional component into the already established control signal and formation of the channel for that component. Control signal correction during the signal synthesis stage in the control device constitutes the basis for the second method. Research results have shown high efficiency of application for both correction methods. Both methods have roughly the same precision. We have shown that the correction in the control device is preferable because it has no influence on the inner contour of the system. We have shown the necessity of the block usage with the variable transmission coefficient, which value is determined by technological trajectory parameters. Research results can be applied in practice for improvement of the precision specifications of automatic control systems for trajectorial manipulators.

  13. Modeling and automatic feedback control of tremor: adaptive estimation of deep brain stimulation.

    Directory of Open Access Journals (Sweden)

    Muhammad Rehan

    Full Text Available This paper discusses modeling and automatic feedback control of (postural and rest tremor for adaptive-control-methodology-based estimation of deep brain stimulation (DBS parameters. The simplest linear oscillator-based tremor model, between stimulation amplitude and tremor, is investigated by utilizing input-output knowledge. Further, a nonlinear generalization of the oscillator-based tremor model, useful for derivation of a control strategy involving incorporation of parametric-bound knowledge, is provided. Using the Lyapunov method, a robust adaptive output feedback control law, based on measurement of the tremor signal from the fingers of a patient, is formulated to estimate the stimulation amplitude required to control the tremor. By means of the proposed control strategy, an algorithm is developed for estimation of DBS parameters such as amplitude, frequency and pulse width, which provides a framework for development of an automatic clinical device for control of motor symptoms. The DBS parameter estimation results for the proposed control scheme are verified through numerical simulations.

  14. Study on Rear-end Real-time Data Quality Control Method of Regional Automatic Weather Station

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    [Objective] The aim was to study the rear-end real-time data quality control method of regional automatic weather station. [Method] The basic content and steps of rear-end real-time data quality control of regional automatic weather station were introduced. Each element was treated with systematic quality control procedure. The existence of rear-end real time data of regional meteorological station in Guangxi was expounded. Combining with relevant elements and linear changes, improvement based on traditiona...

  15. AUTOMATIC GENERATION CONTROL OF TWO AREA POWER SYSTEM WITH AND WITHOUT SMES: FROM CONVENTIONAL TO MODERN AND INTELLIGENT CONTROL

    Directory of Open Access Journals (Sweden)

    SATHANS,

    2011-05-01

    Full Text Available This work proposes a Fuzzy Gain Scheduled Proportional-Integral (FGSPI controller for automatic generation control (AGC of two-equal area interconnected thermal power system including the Superconducting Magnetic Energy Storage (SMES unit in both areas. The reheat effect nonlinearity of the steam turbine is also consideredin this study. Simulation results show that the proposed control scheme with SMES is very effective in damping the frequency and tie-line power oscillations due to load perturbations in one of the areas. To further improve the performance of the controller, a new formulation of the area control error (ACE is also adopted. Theproposed FGSPI controller is compared against conventional PI controller and state feedback LQR controller using settling times, overshoots and undershoots of the power and frequency deviations as performance indices and the performance of the proposed controller is found better than the other two. Simulations have been performed using Matlab®.

  16. The Role of Automatic Radiation Monitoring in Control of Illicit Trafficking of Radioactive Materials in Slovenia

    International Nuclear Information System (INIS)

    Automatic radiation monitoring in Slovenia comprises monitoring of external gamma radiation, aerosol radioactivity, radon progeny concentration, and radioactive deposition measurements. The officer on duty has an important part in assuring proper and undisturbed functioning of our automatic radiation monitoring. He is the one who gets the first alert message on radiation levels when exceeded pre-set values in the territory of Slovenia. Together with continuous control over the functioning of automatic radiation monitoring, the officer on duty has been also assigned for receiving messages from users, who carry the 'Radiation pager' (it is a trade mark for Sensor Technology Engineering, inc. from USA). All valuable experiences of the officer on duty who has been accepting reports from customs officers, police officers, from Slovenian radiation and nuclear safety inspectors, are described in this article. The officer on duty with his new role contributes to prevention of the illicit trafficking and inadvertent movement of radioactive materials over the territory of Slovenia. In the last year there where many different causes of emergency calls: from many cases of patient after radioisotopes medical treatment to serious rejected shipment with exceeded radiation. This is only a beginning of responsible task how to introduce and assure the control of the inadvertent movement of radioactive materials in Slovenia. (author)

  17. Automatic Calibration of Frequency Compensation System in Computer-Controlled Patch-Clamp Amplifier

    Directory of Open Access Journals (Sweden)

    Jun Xion

    2007-01-01

    Full Text Available Computer-controlled patch-clamp amplifier is a digitally controlled analog device used to record the cellular ion channel currents in electrophysiology research. The inherent bandwidth and performance of the headstage is limited by the stray capacitance and distributed capacitance across the feedback resistors. In order to effectively improve the performance of the headstage, the paper advanced a simplified automatic calibration method of frequency compensation system in resistor-feedback patch-clamp amplifier. The dynamic model of headstage was approximate as a two poles and one zero system in the transfer function by experience and test results, so the dynamic characteristics of the headstage were obtained employing least squares parameter estimation algorithm. Further more, the compensation parameter of high frequency booster can be estimated by the time constant of main pole of headstage. And automatic adjustment of the parameters in transient response correction stage was performed as a least squares fitting problem. The software routine running on the host computer conducted all operations of frequency compensation. Experimental results demonstrate that the simplified automatic calibration method can substantially extend the bandwidth and minimize step response error of headstage.

  18. STUDY ON THE AUTOMATIC REGULATION SYSTEM OF WIND RATE FUZZY CONTROL

    Institute of Scientific and Technical Information of China (English)

    李敬兆; 张崇巍; 周时欢; 王清灵

    2000-01-01

    This paper presents the solution of regulating the wind rate automatically by means of fuzzy control technology and implementing it with PLC (programmable logical controller) under the circumstance of many influence factors, which exists in the axial-flow fans wind rate regulation system during the process of mine ventilation, and has difficulty in modifying the mathematic model to obtain the satisfied result by normal control ways. According to this analysis, the intelligent and analytic treatment of fuzzy controller has been made and fuzzy control scheme involving self-regulation divisor and intelligent integral has been deeply proposed. Test result shows that this system based on the scheme above is obviously prior to others in its responsibility such as high-speed, overshoot, control precision and robustness. The system furnishes the great reliability of mine working safety and fans running efficiency.

  19. Clutch fill control of an automatic transmission for heavy-duty vehicle applications

    Science.gov (United States)

    Meng, Fei; Chen, Huiyan; Zhang, Tao; Zhu, Xiaoyuan

    2015-12-01

    In this paper an integrated clutch filling phase control for gearshifts on wet clutch transmissions is developed. In a clutch-to-clutch shift of an automatic transmission, in order to obtain smooth gearshift, it should synchronize the oncoming clutch and the off-going clutch timely as well as precise pressure control for the engagement of the oncoming clutch. However, before the oncoming clutch pressure starts to increase, the initial cavity of the clutch chamber has to be filled first. The filling time and stability of the fill phase are very important for the clutch control. In order to improve the shift quality of the automatic transmission which is equipped on heavy-duty vehicles, the electro-hydraulic clutch actuation system is analysed and modelled. A new fill phase control strategy is proposed based on the system analysis as well as the control parameters are optimized according to the variation of the oil temperature and engine speed. The designed strategy is validated by a simulation work. The results demonstrate that the proposed control strategy and parameters modified method can transit the shift process from the fill phase to the torque phase effectively.

  20. Design and Implementation of Electrostatic Spraying Automatic Controlling System Based on PLC

    Directory of Open Access Journals (Sweden)

    Weidong Jia

    2013-05-01

    Full Text Available The objective of this study was to improve the spraying efficiency and meet the demand of modern agricultural. A new generation of electrostatic sprayer which we designed realized the goals. The automatic controlling system is successfully designed. PLC (Programmable Logic Controller was taken as the control core of the system and LCD touch screen was employed for human-computer interaction interface. The system integrates kinds of techniques including programming, pressure monitoring and sensor technology, etc. The main structure of this equipment, working principle and control system hardware selection will be also introduced in the study. Human-computer interaction software was programmed by the software of Pro Tool/Pro CS. System controlling software was programmed in form of ladder diagram, which realized kinds of functions including ESD protection, accurate quantification, automatic controlling and humanized operation. Test results show that the effective spraying range is between 5 to 6 m, the Volume Median Diameter (VMD is 47.48 µm and the Ultra-Low Volume spray (ULV is realized. The spray deposition rate and effective availability of pesticide is higher than old sprayer. And also this new sprayer runs steadily.

  1. Automatic control of freeboard and turbine operation. Wave Dragon, Nissum Bredning

    Energy Technology Data Exchange (ETDEWEB)

    Kofoed, Jens Peter; Frigaard, P. [Aalborg Univ. (Denmark); Friis-Madsen, Erik [Wave Dragon ApS (Denmark); Nimskov, M. [Balslev (Denmark)

    2004-02-01

    This report deals with the modules for automatic control of freeboard and turbine operation on board the Wave Dragon, Nissum Bredning (WD-NB) prototype, and covers what has been going on up to ultimo 2003. The modules have been implemented on board WD-NB by means of a Siemens PLC. The control and monitoring of the PLC is achieved through a SCADA software package (SIMATIC WinCC V6) running on a Windows 2000 PC situated on board. A preliminary Users manual is available (Nimskov, 2003). The two modules for automatic control of freeboard and turbine operation are denoted 'Buoyancy' and 'Generators', respectively, in the SCADA system. The 'Buoyancy' part controls the freeboard by blowing air into or letting air out of air chambers underneath the structure, and thereby raise or lower it. The 'generator' part controls the generators, and thereby the turbines, by switching them on and of in order to maintain the water level in the reservoir within the specified work span. Furthermore, the generators are controlled by frequency converters, so the rotational speed for each turbine is achieved, corresponding to the optimal operation point. (au)

  2. Application of GA optimization for automatic generation control design in an interconnected power system

    Energy Technology Data Exchange (ETDEWEB)

    Golpira, H., E-mail: hemin.golpira@uok.ac.i [Department of Electrical and Computer Engineering, University of Kurdistan, Sanandaj, PO Box 416, Kurdistan (Iran, Islamic Republic of); Bevrani, H. [Department of Electrical and Computer Engineering, University of Kurdistan, Sanandaj, PO Box 416, Kurdistan (Iran, Islamic Republic of); Golpira, H. [Department of Industrial Engineering, Islamic Azad University, Sanandaj Branch, PO Box 618, Kurdistan (Iran, Islamic Republic of)

    2011-05-15

    Highlights: {yields} A realistic model for automatic generation control (AGC) design is proposed. {yields} The model considers GRC, Speed governor dead band, filters and time delay. {yields} The model provides an accurate model for the digital simulations. -- Abstract: This paper addresses a realistic model for automatic generation control (AGC) design in an interconnected power system. The proposed scheme considers generation rate constraint (GRC), dead band, and time delay imposed to the power system by governor-turbine, filters, thermodynamic process, and communication channels. Simplicity of structure and acceptable response of the well-known integral controller make it attractive for the power system AGC design problem. The Genetic algorithm (GA) is used to compute the decentralized control parameters to achieve an optimum operating point. A 3-control area power system is considered as a test system, and the closed-loop performance is examined in the presence of various constraints scenarios. It is shown that neglecting above physical constraints simultaneously or in part, leads to impractical and invalid results and may affect the system security, reliability and integrity. Taking to account the advantages of GA besides considering a more complete dynamic model provides a flexible and more realistic AGC system in comparison of existing conventional schemes.

  3. Automatic Generation Control in Multi Area Interconnected Power System by using HVDC Links

    Directory of Open Access Journals (Sweden)

    Yogendra Arya

    2012-01-01

    Full Text Available This paper investigates the effects of HVDC link in parallel with HVAC link on automatic generation control (AGC problem for a multi-area power system taking into consideration system parameter variations. A fuzzy logic controller is proposed for four area power system interconnected via parallel HVAC/HVDC transmission link which is also referred as asynchronous tie-lines. The linear model of HVAC/HVDC link is developed and the system responses to sudden load change are studied. The simulation studies are carried out for a four area interconnected thermal power system. Suitable solution for automatic generation control problem of four area electrical power system is obtained by means of improving the dynamic performance of power system under study. Robustness of controller is also checked by varying parameters. Simulation results indicate that the scheme works well. The dynamic analyses have been done with and without HVDC link using fuzzy logic controller in Matlab-Simulink. Further a comparison between the two is presented and it has been shown that the performance of the proposed scheme is superior in terms of overshoot and settling time.

  4. Electric Drive Discrete Control System with Automatic Switching-On Reserve for Autonomous Settlement

    Directory of Open Access Journals (Sweden)

    Tsytovich L.I.

    2015-08-01

    Full Text Available The paper aims at developing of control the water supply system’s electric drives for autonomous settlement. The system provides automatic switching to a reserve control channel at refusal of any of the functional elements of the working regulation channel. Usually, such systems have a test signal generator and analyzer to system response to their impact. This result to an increase in the structural redundancy of the system, increase its cost and increase the requirements for the staff qualification. A specific feature of the system is its ability to self-diagnosis of catastrophic malfunctions of scheme’s components and an automatic switching-on the reserve control channels, without applying any test signals to the whole complex of electrical equipment. Multi-zone integrating regulator with frequency-pulse-width modulation realizes this technical solution. Control system structure and signals timing diagrams are presented. The construction principle of adaptive interval-code synchronization device with improved noise stability to control the voltage regulators serving for smooth start-up of asynchronous motors of water pumps is considered as well. Such solution allowing increase noise stability and reliability work of the system in conditions of limited power electrical networks, which is characteristic for the autonomous settlements. The article may be of interest to specialists in the field of power electronics and information electronics, electric drives and process automation.

  5. INVARIAN AUTOMATIC CONTROL SYSTEM, USING THE INTERMEDIATE-FREQUENCY SIGNALS OF HEAT POWER PARAMETERS

    Directory of Open Access Journals (Sweden)

    G. T. Kulakov

    2015-01-01

    Full Text Available The usage of digital micro-processing automatic means allow to use design methods (technique of automatic control systems  more wider, and also to apply optimal ways of control, for example, it is possible to combine the Method of structural-parameter optimization and invariance theory. This method allow to increase essential system speed in processing of task jump and to reduce operation time of outside external disturbance up to two  values of regulated influence, and the usage of invariance principle is based on an additional measuring of the most dangerous perturbation influence and in connection with it the improvement of regulation quality is achieved.In this article the principle of invariance is applied in order to improve greatly external disturbance attack by consumption of over-heated steam. Compensation of disturbance influence on regulated value is achieving by introduction of additional signal on input of correction regulator from output of compensation device, measuring the external disturbance by consumption of over-heated steam.Modeling results of transient processes of cascade system of automatic control (CSAC, on the base of which were realized the unity of these methods, demonstrated the fact that, in processing of external disturbance by consumption of steam, the reduction of maximal dynamic regulation error is six times and cutting of regulation time by 30 % in comparison with CSAC without compensation device of external disturbance. And that is why it leads to the further reduction of maximal dynamic regulation error in processing of external disturbance by consumption of steam, and this allows to improve the quality of control.

  6. Designing of an Automatic Paraffin Controlling Device for a Beam Well

    Institute of Scientific and Technical Information of China (English)

    YAN Jian; LIU Xiao-juan; LI Shu-qin; YANG Shi-hao; ZHANG Ning-sheng

    2008-01-01

    Aiming at the paraffin-deposition problem of a beam well,the automatic paraffin-controlling device is designed by making use of ratchet-pallet mechanism,cam echanism and modern designing method.The device has four main functions:paraffin-controlling,paraffin removal,centralizing the pumping rod,and improving the safety of well tubing.This device integrates the advantages of the paraffin control,such as strong magnetic paraffin controlling and mechanical paraffin-cntting.Theoretical analysis shows that this device has fine working reliability.It turns out to be a new device which can solve the paraffin-deposition problem of a beam well economieally and efficiently.

  7. Improvement of the Automatic System for Control of the Motion of a Physical Object under Uncertainty

    Directory of Open Access Journals (Sweden)

    V.V. Sheludchenko

    2015-10-01

    Full Text Available The effect of the coefficients of sensitivity and test impacts on the criterion of quality of the emergency deceleration control process of a physical object in terms of a significant change in the shape of the output characteristics and the position of the optimum that allowed to identify ways to improve the adaptive properties of automatic control systems (ACS of such objects is revealed. The relationship between the rational values of the ratio of trial stress and the measured parameters of the control object, which allowed to perform the optimization variable coefficient test impacts on the criterion of deviation of the control object from the extreme mode of operation is defined.

  8. Hybrid Chaotic Particle Swarm Optimization Based Gains For Deregulated Automatic Generation Control

    Directory of Open Access Journals (Sweden)

    Cheshta Jain Dr. H. K. Verma

    2011-12-01

    Full Text Available Generation control is an important objective of power system operation. In modern power system, the traditional automatic generation control (AGC is modified by incorporating the effect of bilateral contracts. This paper investigates application of chaotic particle swarm optimization (CPSO for optimized operation of restructured AGC system. To obtain optimum gains of controllers, application of adaptive inertia weight factor and constriction factors is proposed to improve performance of particle swarm optimization (PSO algorithm. It is also observed that chaos mapping using logistic map sequence increases convergence rate of traditional PSO algorithm. The hybrid method presented in this paper gives global optimum gains of controller with significant improvement in convergence rate over basic PSO algorithm. The effectiveness and efficiency of the proposed algorithm have been tested on two area restructure system.

  9. OPTIMAL TORQUE CONTROL STRATEGY FOR PARALLEL HYBRID ELECTRIC VEHICLE WITH AUTOMATIC MECHANICAL TRANSMISSION

    Institute of Scientific and Technical Information of China (English)

    GU Yanchun; YIN Chengliang; ZHANG Jianwu

    2007-01-01

    In parallel hybrid electrical vehicle (PHEV) equipped with automatic mechanical transmission (AMT), the driving smoothness and the clutch abrasion are the primary considerations for powertrain control during gearshift and clutch operation. To improve these performance indexes of PHEV, a coordinated control system is proposed through the analyzing of HEV powertrain dynamic characteristics. Using the method of minimum principle, the input torque of transmission is optimized to improve the driving sinoothness of vehicle. Using the methods of fuzzy logic and fuzzy-PID, the engaging speed of clutch and the throttle opening of engine are manipulated to ensure the smoothness of clutch engagement and reduce the abrasion of clutch friction plates. The motor provides the difference between the required input torque of transmission and the torque transmitted through clutch plates. Results of simulation and experiments show that the proposed control strategy performs better than the contrastive control system, the smoothness of driving and the abrasion of clutch can be improved simultaneously.

  10. A Novel Approach for Automatic Control of Piezoelectric Elements Used for Lorentz Force Detuning Compensation

    CERN Document Server

    Przygoda, K; Napieralski, A; Grecki, M

    2010-01-01

    Abstract: Linear accelerators such as Free Electron Lasers (FELs) use superconducting (SC) resonant cavities to accelerate electron beam to high energies. TESLA type resonators are extremely sensitive to detuning induced by mechanical deformations – Lorentz force detuning (LFD), mainly due to the extremely high quality factor (Q) of the 1.3 GHz resonance mode, in the range of 1e6. The resulting modulation of a resonance frequency of the cavity makes power consumption and stability performances of the Low-Latency Radio Frequency (LLRF) control more critical. In order to minimize the RF control efforts and desired stabilities, the fast piezoelectric actuators with digital control systems are commonly used. The paper presents a novel approach for automatic control of piezoelectric actuators used for compensation of Lorentz force detuning, the practical application and carried out tests in accelerating module ACC6 in Free-Electron Laser in Hamburg (FLASH).

  11. Digital controller for a Baum folding machine. [providing automatic counting and machine shutoff

    Science.gov (United States)

    Bryant, W. H. (Inventor)

    1974-01-01

    A digital controller for controlling the operation of a folding machine enables automatic folding of a desired number of sheets responsive to entry of that number into a selector. The controller includes three decade counter stages for corresponding rows of units, tens and hundreds push buttons. Each stage including a decimal-to-BCD encoder, a buffer register, and a digital or binary counter. The BCD representation of the selected count for each digit is loaded into the respective decade down counters. Pulses generated by a sensor and associated circuitry are used to decrease the count in the decade counters. When the content of the decade counter reaches either 0 or 1, a solenoid control valve is actuated which interrupts operation of the machine. A repeat switch, when actuated, prevents clearing of the buffer registers so that multiple groups of the same number of sheets can be folded without reentering the number into the selector.

  12. Developing an intelligent control system of automatic window motor with diverse wireless sensor network devices

    Indian Academy of Sciences (India)

    Yao-Chiang Kan; Hsueh-Chun Lin; Wen-Pei Sung

    2014-08-01

    This invention system involves hardware, firmware and software to develop an intelligent control system of automatic window motor with diverse wireless sensor network (WSN) devices for health and environmental monitoring. The parts of this invention are improved by implementing the WSN mote into environmental sensors that may detect temperature, humility, toxic gas, smog or aerosol, etc. With embedded system design, these sensors are capable of delivering WSN signal packets based on ZigBee protocol that follows the IEEE 802.14.4 standards. The primary hardware of the system is the window motor with circuit design by integrating micro control unit (MCU), radio frequency (RF) and WSN antenna to receive command. The firmware developed under embedded system can bridge hardware and software to control the window at the specified position. At the back end, the control system software can manage diverse sensor data and provide the interface for remote monitoring.

  13. Automatic quality control in the production of ceramic substrates by pulsed laser cutting

    DEFF Research Database (Denmark)

    Morace, Renate Erica; Hansen, Hans Nørgaard; De Chiffre, Leonardo;

    2004-01-01

    This paper deals with the use of optical coordinate measuring machines (CMMs) in the quality control of ceramic substrates produced by a CO2 pulsed laser. A procedure of automatic measurements on a CMM equipped with a CCD camera was developed. In particular, the number and the distribution...... of cavities on the cut face of thin ceramic substrates were investigated and different strategies to assess the depth and the pitch of cavities were compared. Then, the measurement uncertainty for these two critical parameters was evaluated using the method described in ISO/TS 15530-3....

  14. A review of automatic exposure control of conventional and digital systems

    International Nuclear Information System (INIS)

    The desirable properties and methods of achieving automatic exposure control in film-screen radiography, fluoroscopy, spot-film fluorography and cinefluorography are discussed. Advantages of certain methods in achieving optimum image quality for minimal patient exposure are considered. In digital subtraction fluorography (DSF) where relatively large exposure levels per image are used, proper set-up of exposure conditions is of particular importance. These systems require a high degree of stability in exposure to maintain a high level of image quality. We have developed test methods for monitoring the set-up and reproducibility of exposure levels in DSF. (author)

  15. Automatic control system of high precision welding of workpieces in mechanical engineering

    Science.gov (United States)

    Kuznetsov, I. N.; Zvezdin, V. V.; Israfilov, I. H.; Portnov, S. M.

    2014-12-01

    In this paper, based on the conducted patent research, the system of laser welding control with different geometry of weld and shapes of parts is developed. The method of monitoring the position of the spot of laser radiation in relation to the curved weld is worked out; it is based on the tracking the edges of the welded parts by low-power laser radiation reflected from the surface of the parts. It allows to make the positioning of the focus of laser radiation in relation to the juncture of the welded parts automatically.

  16. X-ray detector for automatic exposure control using ionization chamber filled with xenon gas

    CERN Document Server

    Nakagawa, A; Yoshida, T

    2003-01-01

    This report refers to our newly developed X-ray detector for reliable automatic X-ray exposure control, which is to be widely used for X-ray diagnoses in various clinical fields. This new detector utilizes an ionization chamber filled with xenon gas, in contrast to conventional X-ray detectors which use ionization chambers filled with air. Use of xenon gas ensures higher sensitivity and thinner design of the detector. The xenon gas is completely sealed in the chamber, so that the influence of the changes in ambient environments is minimized. (author)

  17. Cross-Calibration of Two Automatic Quality Control Systems for the CMS ECAL Crystals

    CERN Document Server

    Auffray, Etiennette; Chevenier, Guy; Lecoq, Paul; Perez-Prado, P; Schneegans, Marc; Sempere-Roldan, P

    2003-01-01

    The barrel part of the CMS electromagnetic calorimeter consists of about 60000 PWO crystals and will be assembled in two Regional Centers, nearby Rome and at CERN. Two automatic machines have been designed to check the crystal quality before assembly. The main crystal characteristics are compared to a set of specifications included in the contract with the crystal producers. The stability and intercalibration between the two is a fundamental issue, which has to be controlled during the whole construction phase. This paper describes the checks that were made in order to cross calibrate the measurements and to guarantee a proper selection of crystals for the detector.

  18. Automatic Shape Control of Triangular B-Splines of Arbitrary Topology

    Institute of Scientific and Technical Information of China (English)

    Ying He; Xian-Feng Gu; Hong Qin

    2006-01-01

    Triangular B-splines are powerful and flexible in modeling a broader class of geometric objects defined over arbitrary, non-rectangular domains. Despite their great potential and advantages in theory, practical techniques and computational tools with triangular B-splines are less-developed. This is mainly because users have to handle a large number of irregularly distributed control points over arbitrary triangulation. In this paper, an automatic and efficient method is proposed to generate visually pleasing, high-quality triangular B-splines of arbitrary topology. The experimental results on several real datasets show that triangular B-splines are powerful and effective in both theory and practice.

  19. Using fuzzy logic for automatic control: Case study of a problem of cereals samples classification

    Directory of Open Access Journals (Sweden)

    Lakhoua Najeh Mohamed

    2009-01-01

    Full Text Available The aim of this paper is to present the use of fuzzy logic for automatic control of industrial systems particularly the way to approach a problem of classification. We present a case study of a grading system of cereals that allows us to determine the price of transactions of cereals in Tunisia. Our contribution in this work consists in proposing not only an application of the fuzzy logic on the grading system of cereals but also a methodology enabling the proposing of a new grading system based on the concept of 'Grade' while using the fuzzy logic techniques. .

  20. Control-oriented Automatic System for Transport Analysis (ASTRA)-Matlab integration for Tokamaks

    International Nuclear Information System (INIS)

    The exponential growth in energy consumption has led to a renewed interest in the development of alternatives to fossil fuels. Between the unconventional resources that may help to meet this energy demand, nuclear fusion has arisen as a promising source, which has given way to an unprecedented interest in solving the different control problems existing in nuclear fusion reactors such as Tokamaks. The aim of this manuscript is to show how one of the most popular codes used to simulate the performance of Tokamaks, the Automatic System For Transport Analysis (ASTRA) code, can be integrated into the Matlab-Simulink tool in order to make easier and more comfortable the development of suitable controllers for Tokamaks. As a demonstrative case study to show the feasibility and the goodness of the proposed ASTRA-Matlab integration, a modified anti-windup Proportional Integral Derivative (PID)-based controller for the loop voltage of a Tokamak has been implemented. The integration achieved represents an original and innovative work in the Tokamak control area and it provides new possibilities for the development and application of advanced control schemes to the standardized and widely extended ASTRA transport code for Tokamaks. -- Highlights: → The paper presents a useful tool for rapid prototyping of different solutions to deal with the control problems arising in Tokamaks. → The proposed tool embeds the standardized Automatic System For Transport Analysis (ASTRA) code for Tokamaks within the well-known Matlab-Simulink software. → This allows testing and combining diverse control schemes in a unified way considering the ASTRA as the plant of the system. → A demonstrative Proportional Integral Derivative (PID)-based case study is provided to show the feasibility and capabilities of the proposed integration.

  1. Automatic Control Strategy Development for the Supercritical CO2 Brayton Cycle for LFR Autonomous Load Following

    International Nuclear Information System (INIS)

    The supercritical carbon dioxide (S-CO2) Brayton cycle is a promising advanced alternative to the Rankine saturated steam cycle and ideal gas Brayton cycle for the energy converters of specific reactor concepts belonging to the U.S. Department of Energy Generation IV Nuclear Energy Systems Initiative. A new plant dynamics analysis computer code has been developed for simulation of the S-CO2 Brayton cycle coupled to an autonomous Lead-Cooled Fast Reactor (LFR). The plant dynamics code was used to develop an automatic control strategy for the whole plant in response to changes in the demand from the electrical grid. The specific features of the S-CO2 Brayton cycle that result in limitations on the control range and speed of specific control mechanisms are discussed. Calculations of whole-plant responses to plant operational transients involving step and continuous changes in grid demand are demonstrated. (authors)

  2. Possibilities for Automatic Control of Hydro-Mechanical Transmission and Birotating Electric Machine

    Directory of Open Access Journals (Sweden)

    V. V. Mikhailov

    2014-01-01

    Full Text Available The paper presents mathematical models and results of virtual investigations pertaining to the selected motion parameters of a mobile machine equipped with hydro mechanical and modernized transmissions. The machine has been tested in similar technological cycles and it has been equipped with a universal automatic control system. Changes in structure and type of power transmission have been obtained with the help of a control algorithm including an extra reversible electric machine which is switched in at some operational modes.Implementation of the proposed  concept makes it possible to obtain and check the improved C-code of the control system and enhance operational parameters of the transmission and machine efficiency, reduce slippage and tire wear while using braking energy for its later beneficial use which is usually considered as a consumable element.

  3. Simulation and operation of the EBR-2 automatic control rod drive system

    Science.gov (United States)

    Lehto, W. K.; Larson, H. A.; Dean, E. M.; Christensen, L. J.

    An automatic control rod drive system (ACRDS) installed at EBR-II produces shaped power transients from 40% to full reactor power at a linear ramp rate of 4 MWt/s. A digital computer and modified control rod drive provides this capability. Simulation and analysis of ACRDS experiments establish the safety envelope for reactor transient operation. Tailored transients are required as part of USDOE operational reliability testing program for prototypic fast reactor fuel cladding breach behavior studies. After initial EBR-II driver fuel testing and system checkout, test subassemblies were subjected to both slow and fast transients. In addition, the ACRDS is used for steady state operation and will be qualified to control power ascent from initial critical to full power.

  4. Design and construction of indigenously electronic boards for the automatic control of MNSR

    International Nuclear Information System (INIS)

    Development, implementation, and manufacturing, indigenously, the first-of-a kind prototype of the electronic automatic control board of MSNR was made in this work. The new prototype includes some specific modifications that take into consideration the availability of electronic elements in the local market, the possibility to manufacture the control board indigenously, and the availability of such board as spare parts on reserve: The manufactured board has been tested (as cooled test) to check for functionality or malfunction before installation as part of the control and operating system. Later on, the board will be installed and tested as part of the above mentioned system to check whether it functions correctly under normal operating conditions (as hot test). (author)

  5. Multi-Stage Optimization Based Automatic Voltage Control Systems Considering Wind Power Forecasting Errors

    DEFF Research Database (Denmark)

    Qin, Nan; Bak, Claus Leth; Abildgaard, Hans;

    2016-01-01

    This paper proposes an automatic voltage control (AVC) system for power systems with limited continuous voltage control capability. The objective is to minimize the operational cost over a period, which consists of the power loss in the grid, the shunt switching cost, the transformer tap change...... cost and the generator reactive power output cost. The problem is formulated in a multi-stage optimal reactive power flow (MORPF) framework, solved by the nonlinear programming techniques via a rolling process. The voltage uncertainty caused by wind power forecasting errors is considered in the optimal...... electricity control center, where study cases based on the western Danish power system demonstrate the superiority of the proposed AVC system in term of the cost minimization. Monte Carlo simulations are carried out to verify the proposed method on the robustness improvements....

  6. Automatic Method for Controlling the Iodine Adsorption Number in Carbon Black Oil Furnaces

    Directory of Open Access Journals (Sweden)

    Zečević, N.

    2008-12-01

    Full Text Available There are numerous of different inlet process factors in carbon black oil furnaces which must be continuously and automatically adjusted, due to stable quality of final product. The most important six inlet process factors in carbon black oil-furnaces are:1. volume flow of process air for combustion2. temperature of process air for combustion3. volume flow of natural gas for insurance the necessary heat for thermal reaction of conversionthe hydrocarbon oil feedstock in oil-furnace carbon black4. mass flow rate of hydrocarbon oil feedstock5. type and quantity of additive for adjustment the structure of oil-furnace carbon black6. quantity and position of the quench water for cooling the reaction of oil-furnace carbon black.The control of oil-furnace carbon black adsorption capacity is made with mass flow rate of hydrocarbon feedstock, which is the most important inlet process factor. Oil-furnace carbon black adsorption capacity in industrial process is determined with laboratory analyze of iodine adsorption number. It is shown continuously and automatically method for controlling iodine adsorption number in carbon black oil-furnaces to get as much as possible efficient control of adsorption capacity. In the proposed method it can be seen the correlation between qualitatively-quantitatively composition of the process tail gasses in the production of oil-furnace carbon black and relationship between air for combustion and hydrocarbon feedstock. It is shown that the ratio between air for combustion and hydrocarbon oil feedstock is depended of adsorption capacity summarized by iodine adsorption number, regarding to BMCI index of hydrocarbon oil feedstock.The mentioned correlation can be seen through the figures from 1. to 4. From the whole composition of the process tail gasses the best correlation for continuously and automatically control of iodine adsorption number is show the volume fraction of methane. The volume fraction of methane in the

  7. GSM Web-Based Centralized Remote Wireless Automatic Controlling and Monitoring of Aquafeeder

    Science.gov (United States)

    Wong, C. L.; Idris, A.; Hasan, Z.

    2016-03-01

    This project is about producing a prototype to feed fishes at fish ponds of remote location with the use of GSM mobile phone. An automatic fish feeder is an electric device that has been designed to give out the right amount of pellets at the designed time. In this project, the automatic feeder designed consists of photovoltaic solar cells that are used to generate electricity and storing it into batteries. Solar charge controllers can be used to determine the rate of which current is drawn and added from the batteries. GSM cellular communication is used to allow user to control from a distance. Commands or instructions are sent to the operating system which in return runs the servomotor and blower by blowing certain amount of fish pallets into the pond to feed the fishes. The duration of the feeding processes is fixed by the user, hence the amount of fish food pallets released are precisely the same for each time. This technology is especially useful for fish farmers where they can remotely feed their fishes.

  8. Tunning PID controller using particle swarm optimization algorithm on automatic voltage regulator system

    Science.gov (United States)

    Aranza, M. F.; Kustija, J.; Trisno, B.; Hakim, D. L.

    2016-04-01

    PID Controller (Proportional Integral Derivative) was invented since 1910, but till today still is used in industries, even though there are many kind of modern controllers like fuzz controller and neural network controller are being developed. Performance of PID controller is depend on on Proportional Gain (Kp), Integral Gain (Ki) and Derivative Gain (Kd). These gains can be got by using method Ziegler-Nichols (ZN), gain-phase margin, Root Locus, Minimum Variance dan Gain Scheduling however these methods are not optimal to control systems that nonlinear and have high-orde, in addition, some methods relative hard. To solve those obstacles, particle swarm optimization (PSO) algorithm is proposed to get optimal Kp, Ki and Kd. PSO is proposed because PSO has convergent result and not require many iterations. On this research, PID controller is applied on AVR (Automatic Voltage Regulator). Based on result of analyzing transient, stability Root Locus and frequency response, performance of PID controller is better than Ziegler-Nichols.

  9. Development of an Automatic Frequency Control (AFC) System for RF Electron Linear Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Sungsu; Kim, Yujong; Lee, Byeong-No; Joo, Youngwoo; Lee, Soo Min; Lee, Byung Cheol; Cha, Hyungki [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Park, Hyung Dal [Radiation Technology eXcellence, Daejeon (Korea, Republic of); Lee, Seung Hyun [Sungkyunkwan University, Suwon (Korea, Republic of)

    2015-10-15

    In this paper, the design, fabrication, and RF power test of the AFC system for the X-band linac are presented. The main function of the AFC system is automatically matching of the resonance frequency of the accelerating structure and the RF frequency of the magnetron. For the frequency tuning, a fine tuning of 10 kHz is possible by rotating the tuning shaft with a rotation of 0.72 degree per pulse. Therefore, the frequency deviation is about 0.01%, and almost full RF power (2.1 MW) transmission was obtained because the reflected power is minimized. The Radiation Equipment Research Division of the Korea Atomic Energy Research Institute has been developing and upgrading a medical/industrial X-band RF electron linear accelerators. The medical compact RF electron linear accelerator consists of an electron gun, an acceleration tube (accelerating structure), two solenoid magnets, two steering magnets, a magnetron, modulator, an automatic frequency control (AFC) system, and an X-ray generating target. The accelerating structure of the component is composed of oxygen-free high-conductivity copper (OFHC). Therefore, the volume of the structure, hence, its resonance frequency can easily be changeable if the ambient temperature and pressure are changed. If the RF frequency of the 9300 MHz magnetron and the resonance frequency of accelerating structure are not matched, performance of the structure can be degraded. An AFC system is automatically matched with the RF frequency of the magnetron and resonance frequency of the accelerating structure, which obtained a high output power and reliable accelerator operation.

  10. Availability verification of information for human system interface in automatic SG level control using activity diagram

    Energy Technology Data Exchange (ETDEWEB)

    Nuraslinda, Anuar; Kim, Dong Young; Kim, Jong Hyun [KEPCO International Nuclear Graduate School, Uljugun (Korea, Republic of)

    2012-10-15

    Steam Generator (SG) level control system in OPR 1000 is one of representative automatic systems that falls under the Supervisory Control level in Endsley's taxonomy. Supervisory control of automated systems is classified as a form of out of the loop (OOTL) performance due to passive involvement in the systems operation, which could lead to loss of situation awareness (SA). There was a reported event, which was caused by inadequate human automation communication that contributed to an unexpected reactor trip in July 2005. A high SG level trip occurred in Yeonggwang (YGN) Unit 6 Nuclear Power Plant (NPP) due to human operator failure to recognize the need to change the control mode of the economizer valve controller (EVC) to manual mode during swap over (the transition from low power mode to high power mode) after the loss of offsite power (LOOP) event was recovered. This paper models the human system interaction in NPP SG level control system using Unified Modeling Language (UML) Activity Diagram. Then, it identifies the missing information for operators in the OPR1000 Main Control Room (MCR) and suggests some means of improving the human system interaction.

  11. Automatic generation control application with craziness based particle swarm optimization in a thermal power system

    Energy Technology Data Exchange (ETDEWEB)

    Gozde, Haluk; Taplamacioglu, M. Cengiz [Gazi University, Faculty of Engineering, Department of Electrical and Electronics Engineering, 06750 Maltepe, Ankara (Turkey)

    2011-01-15

    In this study, a novel gain scheduling Proportional-plus-Integral (PI) control strategy is suggested for automatic generation control (AGC) of the two area thermal power system with governor dead-band nonlinearity. In this strategy, the control is evaluated as an optimization problem, and two different cost functions with tuned weight coefficients are derived in order to increase the performance of convergence to the global optima. One of the cost functions is derived through the frequency deviations of the control areas and tie-line power changes. On the other hand, the other one includes the rate of changes which can be variable depends on the time in these deviations. These weight coefficients of the cost functions are also optimized as the controller gains have been done. The craziness based particle swarm optimization (CRAZYPSO) algorithm is preferred to optimize the parameters, because of convergence superiority. At the end of the study, the performance of the control system is compared with the performance which is obtained with classical integral of the squared error (ISE) and the integral of time weighted squared error (ITSE) cost functions through transient response analysis method. The results show that the obtained optimal PI-controller improves the dynamic performance of the power system as expected as mentioned in literature. (author)

  12. The alternate wire-feed control in the automatic CO2 arc welding

    Institute of Scientific and Technical Information of China (English)

    卢亚静; 胡绳荪; 易小林; 单平

    2004-01-01

    In the automatic CO2 arc welding, the alteration of the vertical distance between the welding torch and the workpiece has a strong effect on the welding parameters such as welding current and voltage, with the result that the appearance and quality of weld are not steady. To weaken the influence of the distance alteration, a method is put forward in the paper. The method is that the alternate wire-feed control is used for compensating the welding current. On the basis of theoretical analysis, a static numerical model for alternate wire-feed control is established. The experiments show that the model-based regulation of the wire feed rate can compensate the welding current and ensure the appearance of weld. When the alteration of vertical distance between the torch and the workpiece is greater, not only is the wire feed rate regulated, but the output voltage of the power source is adjusted to ensure the appearance and quality of weld.

  13. Automatic diameter control system applied to the laser heated pedestal growth technique

    Directory of Open Access Journals (Sweden)

    Andreeta M.R.B.

    2003-01-01

    Full Text Available We described an automatic diameter control system (ADC, for the laser heated pedestal growth technique, that reduces the diameter fluctuations in oxide fibers grown from unreacted and non-sinterized pedestals, to less than 2% of the average fiber diameter, and diminishes the average diameter fluctuation, over the entire length of the fiber, to less than 1%. The ADC apparatus is based on an artificial vision system that controls the pulling speed and the height of the molten zone within a precision of 30 mum. We also show that this system can be used for periodic in situ axial doping the fiber. Pure and Cr3+ doped LaAlO3 and pure LiNbO3 were usedas model materials.

  14. Embedded Wireless Based Communications and Security Application for Oilfield for Automatic Controlling

    Directory of Open Access Journals (Sweden)

    Ganesh V Padole

    2011-07-01

    Full Text Available The site of oil-well is distributed dispersedly, but distribution area is wide. Oil exhauster continuous working for 24 hours. As the problem of petroleum being stolen, transmission line being stolen, and transformer being stolen exists which requires the strong secures management system. With Consideration of the objective condition restriction of geographical environment, the implementation of safe management for oilfield is very difficult. We overcome these difficulties, which comes from geographical environment. The cost is not only high if the fiber cable would be lay between working station in the several tens of square kilometers, but also need to put into a lot of human and material resources with line maintenance and guard against theft. It is a perfect scheme that remote wireless monitoring and control system is established. The system is required to manage the data received from the various site and providing the security by managing and providing automatic controlling structure.

  15. Automatic control of finite element models for temperature-controlled radiofrequency ablation

    Directory of Open Access Journals (Sweden)

    Haemmerich Dieter

    2005-07-01

    Full Text Available Abstract Background The finite element method (FEM has been used to simulate cardiac and hepatic radiofrequency (RF ablation. The FEM allows modeling of complex geometries that cannot be solved by analytical methods or finite difference models. In both hepatic and cardiac RF ablation a common control mode is temperature-controlled mode. Commercial FEM packages don't support automating temperature control. Most researchers manually control the applied power by trial and error to keep the tip temperature of the electrodes constant. Methods We implemented a PI controller in a control program written in C++. The program checks the tip temperature after each step and controls the applied voltage to keep temperature constant. We created a closed loop system consisting of a FEM model and the software controlling the applied voltage. The control parameters for the controller were optimized using a closed loop system simulation. Results We present results of a temperature controlled 3-D FEM model of a RITA model 30 electrode. The control software effectively controlled applied voltage in the FEM model to obtain, and keep electrodes at target temperature of 100°C. The closed loop system simulation output closely correlated with the FEM model, and allowed us to optimize control parameters. Discussion The closed loop control of the FEM model allowed us to implement temperature controlled RF ablation with minimal user input.

  16. A Simulink Library of cryogenic components to automatically generate control schemes for large Cryorefrigerators

    Science.gov (United States)

    Bonne, François; Alamir, Mazen; Hoa, Christine; Bonnay, Patrick; Bon-Mardion, Michel; Monteiro, Lionel

    2015-12-01

    In this article, we present a new Simulink library of cryogenics components (such as valve, phase separator, mixer, heat exchanger...) to assemble to generate model-based control schemes. Every component is described by its algebraic or differential equation and can be assembled with others to build the dynamical model of a complete refrigerator or the model of a subpart of it. The obtained model can be used to automatically design advanced model based control scheme. It also can be used to design a model based PI controller. Advanced control schemes aim to replace classical user experience designed approaches usually based on many independent PI controllers. This is particularly useful in the case where cryoplants are submitted to large pulsed thermal loads, expected to take place in future fusion reactors such as those expected in the cryogenic cooling systems of the International Thermonuclear Experimental Reactor (ITER) or the Japan Torus-60 Super Advanced Fusion Experiment (JT- 60SA). The paper gives the example of the generation of the dynamical model of the 400W@1.8K refrigerator and shows how to build a Constrained Model Predictive Control for it. Based on the scheme, experimental results will be given. This work is being supported by the French national research agency (ANR) through the ANR-13-SEED-0005 CRYOGREEN program.

  17. Cardiovascular Automatic Feedback Control Instrument for Rescuing Critical Patients With Abnormal Blood Pressure

    Institute of Scientific and Technical Information of China (English)

    Ge Yuzhi; Wu Zhiting; Sheng Guotai; Li Gang

    2006-01-01

    Objectives Most medical instruments are designed for diagnosis purpose but very few for clinical treatment. Our research aim is to design and develop a cardiovascular automatic feedback control instrument (CAFCI) for rescuing the critical patients with abnormal blood pressure.Methods The CAFCI was designed on the basis of abundant clinical experiences and on successful mathematic modeling of our experimental data. The blood pressure, pulmonary capillary wedge pressure,and rates of heart beat were measured and inputted into a computer and drugs were chosen by a doctor through a user-friendly interface with the computer.The responses to medication were rapidly acquired and feed back to the computer by automatic detection system in a close-loop system. The data were refreshed every 7.5 sec in order to regulate the speed and dosage of the medications that were given. Results The experimental results with ten dogs showed that the CAFCI system took samples promptly and accurately so that the targeted blood pressure could be reached reliably based on our input parameters and our designing requirements. Conclusions Since the dependability and accuracy of the CAFCI system are much superior to that of the traditional method, its clinical application to rescue the critical patient warrants evaluation in the future.

  18. Hardware simulation of automatic braking system based on fuzzy logic control

    Directory of Open Access Journals (Sweden)

    Noor Cholis Basjaruddin

    2016-07-01

    Full Text Available In certain situations, a moving or stationary object can be a barrier for a vehicle. People and vehicles crossing could potentially get hit by a vehicle. Objects around roads as sidewalks, road separator, power poles, and railroad gates are also a potential source of danger when the driver is inattentive in driving the vehicle. A device that can help the driver to brake automatically is known as Automatic Braking System (ABS. ABS is a part of the Advanced Driver Assistance Systems (ADAS, which is a device designed to assist the driver in driving the process. This device was developed to reduce human error that is a major cause of traffic accidents. This paper presents the design of ABS based on fuzzy logic which is simulated in hardware by using a remote control car. The inputs of fuzzy logic are the speed and distance of the object in front of the vehicle, while the output of fuzzy logic is the intensity of braking. The test results on the three variations of speed: slow-speed, medium-speed, and high-speed shows that the design of ABS can work according to design.

  19. Single-beam water vapor detection system with automatic photoelectric conversion gain control

    Science.gov (United States)

    Zhu, C. G.; Chang, J.; Wang, P. P.; Wang, Q.; Wei, W.; Liu, Z.; Zhang, S. S.

    2014-11-01

    A single-beam optical sensor system with automatic photoelectric conversion gain control is proposed for doing high reliability water vapor detection under relatively rough environmental conditions. Comparing to a dual-beam system, it can distinguish the finer photocurrent variations caused by the optical power drift and provide timely compensation by automatically adjusting the photoelectric conversion gain. This system can be rarely affected by the optical power drift caused by fluctuating ambient temperature or variation of fiber bending loss. The deviation of the single-beam system is below 1.11% when photocurrent decays due to fiber bending loss for bending radius of 5 mm, which is obviously lower than the dual-beam system (8.82%). We also demonstrate the long-term stability of the single-beam system by monitoring a 660 ppm by volume (ppmv) water vapor sample continuously for 24 h. The maximum deviation of the measured concentration during the whole testing period does not exceed 10 ppmv. Experiments have shown that the new system features better reliability and is more apt for remote sensing application which is often subject to light transmission loss.

  20. Wind power integration into the automatic generation control of power systems with large-scale wind power

    DEFF Research Database (Denmark)

    Basit, Abdul; Hansen, Anca Daniela; Altin, Müfit;

    2014-01-01

    Transmission system operators have an increased interest in the active participation of wind power plants (WPP) in the power balance control of power systems with large wind power penetration. The emphasis in this study is on the integration of WPPs into the automatic generation control (AGC...

  1. Automatic generation and verification of railway interlocking control tables using FSM and NuSMV

    Directory of Open Access Journals (Sweden)

    Mohammad B. YAZDI

    2009-01-01

    Full Text Available Due to their important role in providing safe conditions for train movements, railway interlocking systems are considered as safety critical systems. The reliability, safety and integrity of these systems, relies on reliability and integrity of all stages in their lifecycle including the design, verification, manufacture, test, operation and maintenance.In this paper, the Automatic generation and verification of interlocking control tables, as one of the most important stages in the interlocking design process has been focused on, by the safety critical research group in the School of Railway Engineering, SRE. Three different subsystems including a graphical signalling layout planner, a Control table generator and a Control table verifier, have been introduced. Using NuSMV model checker, the control table verifier analyses the contents of control table besides the safe train movement conditions and checks for any conflicting settings in the table. This includes settings for conflicting routes, signals, points and also settings for route isolation and single and multiple overlap situations. The latest two settings, as route isolation and multiple overlap situations are from new outcomes of the work comparing to works represented on the subject recently.

  2. Key techniques of automatic gauge control and profile control for aluminium strip and foil

    Institute of Scientific and Technical Information of China (English)

    LI Mou-wei; LIU Hong-fei; WANG Xiang-li; TONG Chao-nan; YIN Feng-fu; BIAN Xin-xiao; ZHANG Lei

    2006-01-01

    Such characteristics of aluminium strip and foil as soft and thin gauge make tension control one of the key techniques for automation gauge control(AGC). To avoid the disadvantage of traditional mathematical control method which is unfitful for nonlinear hysteresis, the technique for tension AGC fuzzy control was developed and thickness deviation more than 3% of product thickness was achieved consequently in 1 350 mm cold rolling mill of aluminium strip and foil. Additionally, because the gauge of aluminium strip and foil is thin, stage-cooling roll method becomes a key technique for profile control. So stage-cooling roll intelligent control method is developed and pre-coated aluminum foil with good profile less than 10 I (the relative differences in elongation of 0.01% ) is produced using the profile control system in 1 400 mm cold rolling mill of aluminium strip and foil.

  3. SIMULATING LOCAL DENSE AREAS USING PMMA TO ASSESS AUTOMATIC EXPOSURE CONTROL IN DIGITAL MAMMOGRAPHY.

    Science.gov (United States)

    Bouwman, R W; Binst, J; Dance, D R; Young, K C; Broeders, M J M; den Heeten, G J; Veldkamp, W J H; Bosmans, H; van Engen, R E

    2016-06-01

    Current digital mammography (DM) X-ray systems are equipped with advanced automatic exposure control (AEC) systems, which determine the exposure factors depending on breast composition. In the supplement of the European guidelines for quality assurance in breast cancer screening and diagnosis, a phantom-based test is included to evaluate the AEC response to local dense areas in terms of signal-to-noise ratio (SNR). This study evaluates the proposed test in terms of SNR and dose for four DM systems. The glandular fraction represented by the local dense area was assessed by analytic calculations. It was found that the proposed test simulates adipose to fully glandular breast compositions in attenuation. The doses associated with the phantoms were found to match well with the patient dose distribution. In conclusion, after some small adaptations, the test is valuable for the assessment of the AEC performance in terms of both SNR and dose. PMID:26977073

  4. A Novel, Automatic Quality Control Scheme for Real Time Image Transmission

    Directory of Open Access Journals (Sweden)

    S. Ramachandran

    2002-01-01

    Full Text Available A novel scheme to compute energy on-the-fly and thereby control the quality of the image frames dynamically is presented along with its FPGA implementation. This scheme is suitable for incorporation in image compression systems such as video encoders. In this new scheme, processing is automatically stopped when the desired quality is achieved for the image being processed by using a concept called pruning. Pruning also increases the processing speed by a factor of more than two when compared to the conventional method of processing without pruning. An MPEG-2 encoder implemented using this scheme is capable of processing good quality monochrome and color images of sizes up to 1024 × 768 pixels at the rate of 42 and 28 frames per second, respectively, with a compression ratio of over 17:1. The encoder is also capable of working in the fixed pruning level mode with user programmable features.

  5. Slow Dynamics Model of Compressed Air Energy Storage and Battery Storage Technologies for Automatic Generation Control

    Energy Technology Data Exchange (ETDEWEB)

    Krishnan, Venkat; Das, Trishna

    2016-05-01

    Increasing variable generation penetration and the consequent increase in short-term variability makes energy storage technologies look attractive, especially in the ancillary market for providing frequency regulation services. This paper presents slow dynamics model for compressed air energy storage and battery storage technologies that can be used in automatic generation control studies to assess the system frequency response and quantify the benefits from storage technologies in providing regulation service. The paper also represents the slow dynamics model of the power system integrated with storage technologies in a complete state space form. The storage technologies have been integrated to the IEEE 24 bus system with single area, and a comparative study of various solution strategies including transmission enhancement and combustion turbine have been performed in terms of generation cycling and frequency response performance metrics.

  6. Regenerative braking control strategy in mild hybrid electric vehicles equipped with automatic manual transmission

    Institute of Scientific and Technical Information of China (English)

    QIN Datong; YE Ming; LIU Zhenjun

    2007-01-01

    The actual regenerative braking force of an integrated starter/generator (ISG),which is varied with desired braking deceleration and vehicle speed,is calculated based on an analysis of the required deceleration,maximum braking force of ISG,engine braking force and state of charge (SOC) of battery.Braking force distribution strategies are presented according to the actual regenerative braking force of ISG.To recover the vehicle's kinetic energy maximally,braking shift rules for a mild hybrid electric vehicle (HEV) equipped with automatic manual transmission (AMT) are brought forward and effects of transmission ratios are considered.A test-bed is built up and regenerative braking tests are carried out.The results show that power recovered by the braking shift rules is more than that recovered by the normal braking control rules.

  7. Fully automatic control of paraplegic FES pedaling using higher-order sliding mode and fuzzy logic control.

    Science.gov (United States)

    Farhoud, Aidin; Erfanian, Abbas

    2014-05-01

    In this paper, a fully automatic robust control strategy is proposed for control of paraplegic pedaling using functional electrical stimulation (FES). The method is based on higher-order sliding mode (HOSM) control and fuzzy logic control. In FES, the strength of muscle contraction can be altered either by varying the pulse width (PW) or by the pulse amplitude (PA) of the stimulation signal. The proposed control strategy regulates simultaneously both PA and PW (i.e., PA/PW modulation). A HOSM controller is designed for regulating the PW and a fuzzy logic controller for the PA. The proposed control scheme is free-model and does not require any offline training phase and subject-specific information. Simulation studies on a virtual patient and experiments on three paraplegic subjects demonstrate good tracking performance and robustness of the proposed control strategy against muscle fatigue and external disturbances during FES-induced pedaling. The results of simulation studies show that the power and cadence tracking errors are 5.4% and 4.8%, respectively. The experimental results indicate that the proposed controller can improve pedaling system efficacy and increase the endurance of FES pedaling. The average of power tracking error over three paraplegic subjects is 7.4±1.4% using PA/PW modulation, while the tracking error is 10.2±1.2% when PW modulation is used. The subjects could pedal for 15 min with about 4.1% power loss at the end of experiment using proposed control strategy, while the power loss is 14.3% using PW modulation. The controller could adjust the stimulation intensity to compensate the muscle fatigue during long period of FES pedaling.

  8. To the question about the states of workability for automatic control systems with complicated structure

    Science.gov (United States)

    Kuznetsov, P. A.; Kovalev, I. V.; Losev, V. V.; Kalinin, A. O.; Murygin, A. V.

    2016-04-01

    The article discusses the reliability of automated control systems. Analyzes the approach to the classification systems for health States. This approach can be as traditional binary approach, operating with the concept of "serviceability", and other variants of estimation of the system state. This article provides one such option, providing selective evaluation of components for the reliability of the entire system. Introduced description of various automatic control systems and their elements from the point of view of health and risk, mathematical method of determining the transition object from state to state, they differ from each other in the implementation of the objective function. Explores the interplay of elements in different States, the aggregate state of the elements connected in series or in parallel. Are the tables of various logic States and the principles of their calculation in series and parallel connection. Through simulation the proposed approach is illustrated by finding the probability of getting into the system state data in parallel and serially connected elements, with their different probabilities of moving from state to state. In general, the materials of article will be useful for analyzing of the reliability the automated control systems and engineering of the highly-reliable systems. Thus, this mechanism to determine the State of the system provides more detailed information about it and allows a selective approach to the reliability of the system as a whole. Detailed results when assessing the reliability of the automated control systems allows the engineer to make an informed decision when designing means of improving reliability.

  9. Towards the implementation of e-manufacturing: design of an automatic tea drying control system

    Directory of Open Access Journals (Sweden)

    Mabvuu, Never

    2014-11-01

    Full Text Available Many of the production costs for producing tea are attributable to the process of drying the tea. E-manufacturing can assist companies to reduce these production costs by making crucial information available to decision-makers so that they can make informed decisions. This paper presents an application of e-manufacturing to the design of an automatic tea drying control system. This control system will ensure that the multiple drying parameters such as temperature, dryer-exit tea moisture content, and fuel consumption are maintained at optimal states during the course of the drying of tea. The additional aim of this system is to balance the cost of production and the quality of the final product. Using the Guggenheim-Anderson-De Boer (GAB model, the optimum drying temperature was found to be 100-110°C, while maintaining a dryer-exit tea moisture content of 3 to 3.12 per cent, at a drying rate of 3 per cent per minute. A Barix control application to control the system’s activities, using the web user interface (WUI, was also developed.

  10. Optimization of the central automatic control of a small Dutch sewer system

    Science.gov (United States)

    Kolechkina, A. G.; Hoes, O. A. C.

    2012-04-01

    A sewer control system was developed in the context of a subsidized project aiming at improvement of surface water quality by control of sewer systems and surface water systems. The project was coordinated by the local water board, "Waterschap Hollandse Delta". Other participants were Delft University of Technology, Deltares and the municipalities Strijen, Cromstrijen, Westmaas, Oud Beijerland and Piershil. As part of the project there were two pilot implementations where a central automatic controller was coupled to the existing SCADA system. For these two pilots the system is now operational. A Dutch urban area in the western part of the Netherlands is usually part of a polder, which is effectively an artificially drained catchment. The urban area itself is split into small subcatchments that manage runoff in different ways. In all cases a large fraction goes into the natural hydrological cycle, but, depending on the design of the local sewer system, a larger or smaller part finds its way into the sewer system. Proper control of this flow is necessary to control surface water quality and to avoid health risks from flow from the sewer into the streets. At each time step the controller switches pumps to distribute the remaining water in the system at the end of the time step over the different subcatchments. The distribution is created based on expert judgment of the relative vulnerability and subcatchment sewer system water quality. It is implemented in terms curves of total system stored volume versus subcatchment stored volume. We describe the process of the adaptation of a controller to two different sewer systems and the understanding of the artificial part of the catchment we gained during this process. In the process of adaptation the type of sewer system (combined foul water and storm water transport or separate foul water and storm water transport) played a major role.

  11. Automatic quality control in clinical (1) H MRSI of brain cancer.

    Science.gov (United States)

    Pedrosa de Barros, Nuno; McKinley, Richard; Knecht, Urspeter; Wiest, Roland; Slotboom, Johannes

    2016-05-01

    MRSI grids frequently show spectra with poor quality, mainly because of the high sensitivity of MRS to field inhomogeneities. These poor quality spectra are prone to quantification and/or interpretation errors that can have a significant impact on the clinical use of spectroscopic data. Therefore, quality control of the spectra should always precede their clinical use. When performed manually, quality assessment of MRSI spectra is not only a tedious and time-consuming task, but is also affected by human subjectivity. Consequently, automatic, fast and reliable methods for spectral quality assessment are of utmost interest. In this article, we present a new random forest-based method for automatic quality assessment of (1) H MRSI brain spectra, which uses a new set of MRS signal features. The random forest classifier was trained on spectra from 40 MRSI grids that were classified as acceptable or non-acceptable by two expert spectroscopists. To account for the effects of intra-rater reliability, each spectrum was rated for quality three times by each rater. The automatic method classified these spectra with an area under the curve (AUC) of 0.976. Furthermore, in the subset of spectra containing only the cases that were classified every time in the same way by the spectroscopists, an AUC of 0.998 was obtained. Feature importance for the classification was also evaluated. Frequency domain skewness and kurtosis, as well as time domain signal-to-noise ratios (SNRs) in the ranges 50-75 ms and 75-100 ms, were the most important features. Given that the method is able to assess a whole MRSI grid faster than a spectroscopist (approximately 3 s versus approximately 3 min), and without loss of accuracy (agreement between classifier trained with just one session and any of the other labelling sessions, 89.88%; agreement between any two labelling sessions, 89.03%), the authors suggest its implementation in the clinical routine. The method presented in this article was implemented

  12. Knowledge-based full-automatic control system for a nuclear ship reactor

    International Nuclear Information System (INIS)

    Plant operations aboard nuclear ships require quick judgements and actions due to changing marine conditions such as wind, waves and currents. Furthermore, additional human support is not available for nuclear ship operation at sea, so advanced automatic operations are necessary to reduce the number of operators required finally. Therefore, an advanced automatic operating system has been developed based on operational knowledge of nuclear ship 'Mutsu' plant. The advanced automatic operating system includes both the automatic operation system and the operator-support system which assists operators in completing actions during plant accidents, anomaly diagnosis and plant supervision. These system are largely being developed using artificial intelligent techniques such as neural network, fuzzy logic and knowledge-based expert. The automatic operation system is fundamentally based upon application of an operator's knowledge of both normal (start-up to rated power level) and abnormal (after scram) operations. Comparing plant behaviors from start-up to power level by the automatic operation with by 'Mutsu' manual operation, stable automatic operation was obtained almost same as manual operation within all operating limits. The abnormal automatic system was for hard work of manual operations after scram or LOCA accidents. An integrating system with the normal and the abnormal automatic systems are being developed for interacting smoothly both systems. (author)

  13. Knowledge-based full-automatic control system for a nuclear ship reactor

    Energy Technology Data Exchange (ETDEWEB)

    Shimazaki, J.; Nakazawa, T.; Yabuuchi, N. [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan)

    2000-03-01

    Plant operations aboard nuclear ships require quick judgements and actions due to changing marine conditions such as wind, waves and currents. Furthermore, additional human support is not available for nuclear ship operation at sea, so advanced automatic operations are necessary to reduce the number of operators required finally. Therefore, an advanced automatic operating system has been developed based on operational knowledge of nuclear ship 'Mutsu' plant. The advanced automatic operating system includes both the automatic operation system and the operator-support system which assists operators in completing actions during plant accidents, anomaly diagnosis and plant supervision. These system are largely being developed using artificial intelligent techniques such as neural network, fuzzy logic and knowledge-based expert. The automatic operation system is fundamentally based upon application of an operator's knowledge of both normal (start-up to rated power level) and abnormal (after scram) operations. Comparing plant behaviors from start-up to power level by the automatic operation with by 'Mutsu' manual operation, stable automatic operation was obtained almost same as manual operation within all operating limits. The abnormal automatic system was for hard work of manual operations after scram or LOCA accidents. An integrating system with the normal and the abnormal automatic systems are being developed for interacting smoothly both systems. (author)

  14. Central automatic control or distributed occupant control for better indoor environment quality in the future

    DEFF Research Database (Denmark)

    Toftum, Jørn

    2010-01-01

    Based on a database accumulated from several recent surveys of office buildings located in a temperate climate (Denmark), the effect on occupant perceptions and symptom prevalence was compared in buildings with natural and with mechanical ventilation in which earlier studies have shown...... a discrepancy in the degree of perceived control. The database was composed of 1272 responses obtained in 24 buildings of which 15 had mechanical ventilation (997 responses) and 9 had natural ventilation (275 responses). The number of occupant-reported control opportunities was higher in buildings with natural...... of control, as perceived by occupants, seemed more important for the prevalence of adverse symptoms and building-related symptoms than the ventilation mode per se. This result indicates that even though the development and application of new indoor environment sensors and HVAC control systems may allow...

  15. Rapid Automatized Naming in Children with Dyslexia: Is Inhibitory Control Involved?

    Science.gov (United States)

    Bexkens, Anika; van den Wildenberg, Wery P M; Tijms, Jurgen

    2015-08-01

    Rapid automatized naming (RAN) is widely seen as an important indicator of dyslexia. The nature of the cognitive processes involved in rapid naming is however still a topic of controversy. We hypothesized that in addition to the involvement of phonological processes and processing speed, RAN is a function of inhibition processes, in particular of interference control. A total 86 children with dyslexia and 31 normal readers were recruited. Our results revealed that in addition to phonological processing and processing speed, interference control predicts rapid naming in dyslexia, but in contrast to these other two cognitive processes, inhibition is not significantly associated with their reading and spelling skills. After variance in reading and spelling associated with processing speed, interference control and phonological processing was partialled out, naming speed was no longer consistently associated with the reading and spelling skills of children with dyslexia. Finally, dyslexic children differed from normal readers on naming speed, literacy skills, phonological processing and processing speed, but not on inhibition processes. Both theoretical and clinical interpretations of these results are discussed.

  16. 11th International Federation of Automatic Control (IFAC) Workshop on Time-Delay Systems

    CERN Document Server

    Fridman, Emilia; Sename, Olivier; Dugard, Luc

    2016-01-01

    This book mostly results from a selection of papers presented during the 11th IFAC (International Federation of Automatic Control) Workshop on Time-Delay Systems, which took place in Grenoble, France, February 4 - 6, 2013.  During this event, 37 papers were presented. Taking into account the reviewers' evaluation and the papers' presentation the best papers have been selected and collected into the present volume. The authors of 13 selected papers were invited to participate to this book and provided a more detailed and improved version of the conference paper. To enrich the book, three more chapters have been included from specialists on time-delay systems who presented their work during the 52nd IEEE Conference on Decision and Control, which held in December 10 - 13, 2013, at Florence, Italy. The content of the book is divided into four main parts as follows: Modeling, Stability analysis, Stabilization and control, and Input-delay systems. Focusing on various topics of time-delay systems, this book will be...

  17. Automatic Gain Control in Mass Spectrometry using a Jet Disrupter Electrode in an Electrodynamic Ion Funnel

    Energy Technology Data Exchange (ETDEWEB)

    Page, Jason S.; Bogdanov, Bogdan; Vilkov, Andrey N.; Prior, David C.; Buschbach, Michael A.; Tang, Keqi; Smith, Richard D.

    2005-02-01

    We report on the use of a jet disrupter electrode in an electrodynamic ion funnel as an electronic valve to regulate the intensity of the ion beam transmitted through the interface of a mass spectrometer in order to perform automatic gain control (AGC). The ion flux is determined by either directly detecting the ion current on the conductance limiting orifice of the ion funnel or using a short mass spectrometry acquisition. Based upon the ion flux intensity, the voltage of the jet disrupter is adjusted to alter the transmission efficiency of the ion funnel to provide a desired ion population to the mass analyzer. Ion beam regulation by an ion funnel is shown to provide an unbiased control to within a few percent of a targeted ion intensity or abundance. The utility of ion funnel AGC was evaluated using a protein tryptic digest analyzed with liquid chromatography Fourier transform ion cyclotron resonance (LC-FTICR) mass spectrometry. The ion population in the ICR cell was accurately controlled to a variety of different levels, which improved data quality and provided better mass measurement accuracy.

  18. Central automatic control or distributed occupant control for better indoor environment quality in the future

    DEFF Research Database (Denmark)

    Toftum, Jørn

    2008-01-01

    of adverse symptoms and building related symptoms than the ventilation mode per se. This result indicates that even though the development and application of new indoor environment sensors and HVAC control systems may allow for fully automated IEQ control, such systems should not compromise occupants......Based on a database accumulated from several recent surveys of office buildings located in a temperate climate (Denmark), the effect on occupant perceptions and symptom prevalence was compared in buildings with natural and mechanical ventilation in which earlier studies have shown a discrepancy...... in the degree of perceived control. The database was composed of 1353 responses obtained in 25 buildings of which 15 had mechanical ventilation (997 responses) and 9 had natural ventilation (275 responses). Analysis of occupant responses, after grouping according to categories determined by the degree...

  19. Comparative evaluation of the effectiveness of manual and automatic control deflection vector airship to take off stage

    OpenAIRE

    В.П. Гусинін; Гусинін, А.В.; О.М. Тачиніна

    2008-01-01

     In paper, results of the comparative effectiveness evaluation of the manual and automatic thrust vector control of airship in the class of «Zeppelin NT» at the takeoff are shown. The gust influences on the airship characteristics and the process of airship takeoff with one out of service engine are considered.

  20. A Computer Model of the Evaporator for the Development of an Automatic Control System

    Science.gov (United States)

    Kozin, K. A.; Efremov, E. V.; Kabrysheva, O. P.; Grachev, M. I.

    2016-08-01

    For the implementation of a closed nuclear fuel cycle it is necessary to carry out a series of experimental studies to justify the choice of technology. In addition, the operation of the radiochemical plant is impossible without high-quality automatic control systems. In the technologies of spent nuclear fuel reprocessing, the method of continuous evaporation is often used for a solution conditioning. Therefore, the effective continuous technological process will depend on the operation of the evaporation equipment. Its essential difference from similar devices is a small size. In this paper the method of mathematic simulation is applied for the investigation of one-effect evaporator with an external heating chamber. Detailed modelling is quite difficult because the phase equilibrium dynamics of the evaporation process is not described. Moreover, there is a relationship with the other process units. The results proved that the study subject is a MIMO plant, nonlinear over separate control channels and not selfbalancing. Adequacy was tested using the experimental data obtained at the laboratory evaporation unit.

  1. Adaptive optics system for fast automatic control of laser beam jitters in air

    Science.gov (United States)

    Grasso, Salvatore; Acernese, Fausto; Romano, Rocco; Barone, Fabrizio

    2010-04-01

    Adaptive Optics (AO) Systems can operate fast automatic control of laser beam jitters for several applications of basic research as well as for the improvement of industrial and medical devices. We here present our theoretical and experimental research showing the opportunity of suppressing laser beam geometrical fluctuations of higher order Hermite Gauss modes in interferometric Gravitational Waves (GW) antennas. This in turn allows to significantly reduce the noise that originates from the coupling of the laser source oscillations with the interferometer asymmetries and introduces the concrete possibility of overcoming the sensitivity limit of the GW antennas actually set at 10-23 1 Hz value. We have carried out the feasibility study of a novel AO System which performs effective laser jitters suppression in the 200 Hz bandwidth. It extracts the wavefront error signals in terms of Hermite Gauss (HG) coefficients and performs the wavefront correction using the Zernike polynomials. An experimental Prototype of the AO System has been implemented and tested in our laboratory at the University of Salerno and the results we have achieved fully confirm effectiveness and robustness of the control upon first and second order laser beam geometrical fluctuations, in good accordance with GW antennas requirements. Above all, we have measured 60 dB reduction of astigmatism and defocus modes at low frequency below 1 Hz and 20 dB reduction in the 200 Hz bandwidth.

  2. Design of an expert system to automatically calibrate impedance control for powered knee prostheses.

    Science.gov (United States)

    Wang, Ding; Liu, Ming; Zhang, Fan; Huang, He

    2013-06-01

    Many currently available powered knee prostheses (PKP) use finite state impedance control to operate a prosthetic knee joint. The desired impedance values were usually manually calibrated with trial-and-error in order to enable near-normal walking pattern. However, such a manual approach is inaccurate, time consuming, and impractical. This paper aimed to design an expert system that can tune the control impedance for powered knee prostheses automatically and quickly. The expert system was designed based on fuzzy logic inference (FLI) to match the desired knee motion and gait timing while walking. The developed system was validated on an able-bodied subject wearing a powered prosthesis. Preliminary experimental results demonstrated that the developed expert system can converge the user's knee profile and gait timing to the desired values within 2 minutes. Additionally, after the auto-tuning procedure, the user produced more symmetrical gait. These preliminary results indicate the promise of the designed expert system for quick and accuracy impedance calibration, which can significantly improve the practical value of powered lower limb prosthesis. Continuous engineering efforts are still needed to determine the calibration objectives and validate the expert system.

  3. Microcomputer-based systems for automatic control of sample irradiation and chemical analysis of short-lived isotopes

    International Nuclear Information System (INIS)

    Two systems resulted from the need for the study of the nuclear decay of short-lived radionuclides. Automation was required for better repeatability, speed of chemical separation after irradiation and for protection from the high radiation fields of the samples. A MCS-8 computer was used as the nucleus of the automatic sample irradiation system because the control system required an extensive multiple-sequential circuit. This approach reduced the sequential problem to a computer program. The automatic chemistry control system is a mixture of a fixed and a computer-based programmable control system. The fixed control receives the irradiated liquid sample from the reactor, extracts the liquid and disposes of the used sample container. The programmable control executes the chemistry program that the user has entered through the teletype. (U.S.)

  4. Automatic Optimization of Focal Point Position in CO2 Laser Welding with Neural Network in A Focus Control System

    DEFF Research Database (Denmark)

    Gong, Hui; Olsen, Flemming Ove

    CO2 lasers are increasingly being utilized for quality welding in production. Considering the high cost of equipment, the start-up time and the set-up time should be minimized. Ideally the parameters should be set up and optimized more or less automatically. In this paper a control system...... is designed and built to automatically optimize the focal point position, one of the most important parameters in CO2 laser welding, in order to perform a desired deep/full penetration welding. The control system mainly consists of a multi-axis motion controller - PMAC, a light sensor - Photo Diode, a data....... The results of the self-learning focus control system show that the neural network is capable of optimizing the focal point position with good accuracy in CW CO2 laser welding....

  5. Evaluation of the use of automatic exposure control and automatic tube potential selection in low-dose cerebrospinal fluid shunt head CT

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, Adam N.; Bagade, Swapnil; Chatterjee, Arindam; Hicks, Brandon; McKinstry, Robert C. [Barnes Jewish Hospital, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Washington University School of Medicine, St. Louis, MO (United States); Vyhmeister, Ross [Washington University School of Medicine, St. Louis, MO (United States); Ramirez-Giraldo, Juan Carlos [Siemens Healthcare, Malvern, PA (United States)

    2015-03-17

    Cerebrospinal fluid shunts are primarily used for the treatment of hydrocephalus. Shunt complications may necessitate multiple non-contrast head CT scans resulting in potentially high levels of radiation dose starting at an early age. A new head CT protocol using automatic exposure control and automated tube potential selection has been implemented at our institution to reduce radiation exposure. The purpose of this study was to evaluate the reduction in radiation dose achieved by this protocol compared with a protocol with fixed parameters. A retrospective sample of 60 non-contrast head CT scans assessing for cerebrospinal fluid shunt malfunction was identified, 30 of which were performed with each protocol. The radiation doses of the two protocols were compared using the volume CT dose index and dose length product. The diagnostic acceptability and quality of each scan were evaluated by three independent readers. The new protocol lowered the average volume CT dose index from 15.2 to 9.2 mGy representing a 39 % reduction (P < 0.01; 95 % CI 35-44 %) and lowered the dose length product from 259.5 to 151.2 mGy/cm representing a 42 % reduction (P < 0.01; 95 % CI 34-50 %). The new protocol produced diagnostically acceptable scans with comparable image quality to the fixed parameter protocol. A pediatric shunt non-contrast head CT protocol using automatic exposure control and automated tube potential selection reduced patient radiation dose compared with a fixed parameter protocol while producing diagnostic images of comparable quality. (orig.)

  6. Modeling and simulation of the generation automatic control of electric power systems; Modelado y simulacion del control automatico de generacion de sistemas electricos de potencia

    Energy Technology Data Exchange (ETDEWEB)

    Caballero Ortiz, Ezequiel

    2002-12-01

    This work is devoted to the analysis of the Automatic Control of Electrical Systems Generation of power, as of the information that generates the loop with Load-Frequency Control and the Automatic Voltage Regulator loop. To accomplish the analysis, the control classical theory and feedback control systems concepts are applied. Thus also, the modern theory concepts are employed. The studies are accomplished in the digital computer through the MATLAB program and the available simulation technique in the SIMULINK tool. In this thesis the theoretical and physical concepts of the automatic control of generation are established; dividing it in load frequency control and automatic voltage regulator loops. The mathematical models of the two control loops are established. Later, the models of the elements are interconnected in order to integrate the loop with load frequency control and the digital simulation of the system is carried out. In first instance, the function of the primary control in are - machine, area - multi machine and multi area - multi machine power systems, is analyzed. Then, the automatic control of generation of the area and multi area power systems is studied. The economic dispatch concept is established and with this plan the power system multi area is simulated, there in after the energy exchange among areas in stationary stage is studied. The mathematical models of the component elements of the control loop of the automatic voltage regulator are interconnected. Data according to the nature of each component are generated and their behavior is simulated to analyze the system response. The two control loops are interconnected and a simulation is carry out with data generated previously, examining the performance of the automatic control of generation and the interaction between the two control loops. Finally, the Poles Positioning and the Optimum Control techniques of the modern control theory are applied to the automatic control of an area generation

  7. Controlling and Reducing of Speed for Vehicles Automatically By Using Rf Technology.

    Directory of Open Access Journals (Sweden)

    Y. Ravindra Babu,

    2014-11-01

    Full Text Available For vehicle safety and safety for passengers in vehicle is an important parameter. Most of the vehicles get accident because no proper safety measures are taken especially at curves and hair pin bends humps and any obstacles in front of the vehicle. This system can be used for the prevention of such a problem by indicating a pre indication and also reducing the speed of vehicles by reducing the fuel rate of vehicle. As the action is in terms of fuel rate so the vehicle automatically goes to control and avoids the accidents. At curves and hair pin bends the line of sight is not possible for the drivers so the special kind of transmitter which is tuned at a frequency of 433MHZ are mounted as these transmitters continuously radiate a RF signal for some particular area. As the vehicle come within this radiation the receiver in the vehicle gets activate. The transmitter used here is a coded transmitter which is encoded with encoder. The encoder provides a 4 bit binary data which is serially transmitted to transmitter. The transmitter used here is ASK type (amplitude shift keying which emits the RF radiation.

  8. Automatic Control of the Reciprocating Compressor%往复压缩机的自动控制

    Institute of Scientific and Technical Information of China (English)

    赵庆林

    2013-01-01

    There are mainly logic control and sequence control in automatic control of the reciprocating compressor, and the difficulty is automatic sequence control for the compressor start or stop.Taking a fresh hydrogen compressor as an example,this paper introduces the configuration of an instrument control system for the fresh hydrogen compressor,the realization of the one button controls for full automatic compressor start or stop operation.The good application effect is received.%往复压缩机的自动控制主要体现在逻辑控制和顺序控制2个方面,其中自动开停机顺序控制是此类压缩机的控制难点.本文以某装置新氢压缩机的自动控制为例,介绍该压缩机的仪表控制系统配置集成、一键式全自动开停机顺序控制方案的实现策略,以及所取得的应用效果.

  9. Automatic component calibration and error diagnostics for model-based accelerator control. Phase I final report

    International Nuclear Information System (INIS)

    Phase I work studied the feasibility of developing software for automatic component calibration and error correction in beamline optics models. A prototype application was developed that corrects quadrupole field strength errors in beamline models

  10. Automatic control of the D20 vapor recovery dryers at Cernavoda NPP U2 (CANDU Project 82)

    International Nuclear Information System (INIS)

    The 'D20 vapor Recovery System' is built in the frame of CANDU NPP Cernavoda, Romania, in order to preserve the atmosphere dry inside the Reactor Building. The system includes ten dryers, four tanks and three pumps grouped in thirteen equipment units with cyclic operation. When desiccant bed of the dryers is full of humidity the operating regime is switched automatically from absorption to regeneration. During regeneration, the air from blower discharge is passed through electric heaters and desiccant bed to condenser where the D20 vapor is recovered, and again to fan inlet. The dryer regeneration is completed when its desiccant bed is hot. Also, transferring the contents of the tanks is a batch processing operation. Considering the Cernavoda U1 operating experience, the CANDU project 82, for Cernavoda NPP U2, is now under an improving process, which implies an Automatic Control for the 'D20 vapor Recovery System'. This Automatic Control, performed by Industrial Computers and Data Acquisition System, is able automatically to detect the completion of the equipment unit phases, to switch the equipment unit to appropriate operation mode, to check the proper operating mode and to trip the equipment unit if necessary. This paper intends to present the problems surmounted during the technical specification issuing for designing process. (author)

  11. Terminal area automatic navigation, guidance and control research using the Microwave Landing System (MLS). Part 5: Design and development of a Digital Integrated Automatic Landing System (DIALS) for steep final approach using modern control techniques

    Science.gov (United States)

    Halyo, N.

    1983-01-01

    The design and development of a 3-D Digital Integrated Automatic Landing System (DIALS) for the Terminal Configured Vehicle (TCV) Research Aircraft, a B-737-100 is described. The system was designed using sampled data Linear Quadratic Gaussian (LOG) methods, resulting in a direct digital design with a modern control structure which consists of a Kalman filter followed by a control gain matrix, all operating at 10 Hz. DIALS uses Microwave Landing System (MLS) position, body-mounted accelerometers, as well as on-board sensors usually available on commercial aircraft, but does not use inertial platforms. The phases of the final approach considered are the localizer and glideslope capture which may be performed simultaneously, localizer and steep glideslope track or hold, crab/decrab and flare to touchdown. DIALS captures, tracks and flares from steep glideslopes ranging from 2.5 deg to 5.5 deg, selected prior to glideslope capture. Digital Integrated Automatic Landing System is the first modern control design automatic landing system successfully flight tested. The results of an initial nonlinear simulation are presented here.

  12. SU-E-I-24: Method for CT Automatic Exposure Control Verification

    Energy Technology Data Exchange (ETDEWEB)

    Gracia, M; Olasolo, J; Martin, M; Bragado, L; Gallardo, N; Miquelez, S; Maneru, F; Lozares, S; Pellejero, S; Rubio, A [Complejo Hospitalario de Navarra, Pamplona, Navarra (Spain)

    2015-06-15

    Purpose: Design of a phantom and a simple method for the automatic exposure control (AEC) verification in CT. This verification is included in the computed tomography (CT) Spanish Quality Assurance Protocol. Methods: The phantom design is made from the head and the body phantom used for the CTDI measurement and PMMA plates (35×35 cm2) of 10 cm thickness. Thereby, three different thicknesses along the longitudinal axis are obtained which permit to evaluate the longitudinal AEC performance. Otherwise, the existent asymmetry in the PMMA layers helps to assess angular and 3D AEC operation.Recent acquisition in our hospital (August 2014) of Nomex electrometer (PTW), together with the 10 cm pencil ionization chamber, led to register dose rate as a function of time. Measurements with this chamber fixed at 0° and 90° on the gantry where made on five multidetector-CTs from principal manufacturers. Results: Individual analysis of measurements shows dose rate variation as a function of phantom thickness. The comparative analysis shows that dose rate is kept constant in the head and neck phantom while the PMMA phantom exhibits an abrupt variation between both results, being greater results at 90° as the thickness of the phantom is 3.5 times larger than in the perpendicular direction. Conclusion: Proposed method is simple, quick and reproducible. Results obtained let a qualitative evaluation of the AEC and they are consistent with the expected behavior. A line of future development is to quantitatively study the intensity modulation and parameters of image quality, and a possible comparative study between different manufacturers.

  13. An evaluation of three simple phantoms used in quality assurance of automatic exposure control

    International Nuclear Information System (INIS)

    Full text: Different attenuators are used to assess the performance of x-ray systems with automatic exposure control (AEC). Three attenuators, copper, water and hardboard, were compared in this assessment. The Health Physics Service (HPS), which is part of the Department of Medical Physics and Bioengineering at Christchurch Hospital, New Zealand, has chosen to use hardboard as its patient equivalent phantom when testing x-ray equipment simply because it is generally easier to handle compared to water phantoms. Tests were conducted on the hardboard phantom in order to evaluate its effect on radiation in terms of attenuation equivalence, production of scatter and sensitivity to different kilovoltages compared to water or copper. Entrance and exit dose comparison tests were conducted using the AEC on a Philips Optimus 50 x-ray machine. A Keithley Triad Field Service Kit Model 10100A was used to record doses. The first set of tests were designed to ascertain the thickness of water and copper required to produce a similar mAs to the particular thickness of hardboard being examined. The tests were repeated with a film in a cassette which was placed in the bucky tray. Film optical densities were then measured. The hardboard phantom shows a very similar response to radiation as water and hence the human body and is therefore a suitable material for use in the construction of phantoms. Copper produces a very different radiation spectrum and its scattering effects are quite different to water or hardboard. For these reasons we consider copper to be unsuitable for use as a phantom when programming AECs. Copyright (2000) Australasian College of Physical Scientists and Engineers in Medicine

  14. The development of an automatic sample-changer and control instrumentation for isotope-source neutron-activation analysis

    International Nuclear Information System (INIS)

    An automatic sample-changer was developed at the Council for Mineral Technology for use in isotope-source neutron-activation analysis. Tests show that the sample-changer can transfer a sample of up to 3 kg in mass over a distance of 3 m within 5 s. In addition, instrumentation in the form of a three-stage sequential timer was developed to control the sequence of irradiation transfer and analysis

  15. Automatic controller to water plants Acionador automático para irrigar plantas

    Directory of Open Access Journals (Sweden)

    Leonardo Oliveira Medici

    2010-12-01

    Full Text Available Despite the massive demand of water for plant irrigation, there are few devices being used in the automation of this process in agriculture. This work evaluates a simple controller to water plants automatically that can be set up with low cost commercial materials, which are large-scale produced. This controller is composed by a ceramic capsule used in common domestic water filters; a plastic tube around 1.5 m long, and a pressostate used in domestic washing machines. The capsule and the pressostate are connected through the tube so that all parts are filled with water. The ceramic capsule is the sensor of the controller and has to be placed into the plant substrate. The pressostate has to be placed below the sensor and the lower it is, the higher is the water tension to start the irrigation, since the lower is the pressostate the higher is the water column above it and, therefore, the higher is the tension inside the ceramic cup to pull up the water column. The controller was evaluated in the control of drip irrigation for small containers filled with commercial organic substrate or soil. Linear regressions explained the relationship between the position of pressostate and the maximum water tension in the commercial substrate (p A despeito da enorme demanda por água na irrigação de plantas, existem poucos aparelhos para automação deste processo sendo usados na agricultura. Avaliou-se um acionador automático para irrigação, o qual pode ser confeccionado com materiais comerciais de baixo custo, pois são produzidos em larga escala. Este acionador é composto por uma cápsula cerâmica usada em filtros de água domésticos; um tubo plástico com cerca de um metro e meio de comprimento e um pressostato de máquinas de lavar roupas domésticas. A cápsula e o pressostato são conectados pelo tubo de forma que todo o espaço interno seja preenchido com água. A cápsula é o sensor do acionador e deve ser posicionada dentro do substrato das

  16. Research and Implementation on Control Algorithm in Automatic Control Glue System%自动控胶系统控制算法的研究与实现

    Institute of Scientific and Technical Information of China (English)

    何斌

    2012-01-01

    自动控胶是胶订机的一个重要工艺过程.自动控胶是以自动控制理论为指导,自动控制技术为手段,实现控胶工艺过程自动化的技术.合理有效的控制算法是实现这一技术的基础,这里讨论的是怎样按照控制工艺过程和控制器件的连接、位置和时序关系建立算法模型.并根据叠加原理,将复杂算法分解成单一算法,逐一实现之.%Automatic Control Glue is an important process in binding machine. Automatic Control Glue is a technology to achieve con-trolled process automation, which is guided by the theory of automatic control and based on automatic control technology. Reasonable and ef-fective control algorithms are the basis for achieving this technical, here is discussing how to build an algorithm model according to technolog-ical process control and control devices, location and timing of connection relationships. According to the principle of superposition,complex algorithms are composed into a single algorithm, and realize them one by one, This control principles and methods have been applied to TB500CM6A elliptic binding package, and have had effective control.

  17. An artificial vision-based control system for automatic heliostat positioning offset correction in a central receiver solar power plant

    Energy Technology Data Exchange (ETDEWEB)

    Berenguel, M. [Universidad de Almeria, Dept. de Lenguajes y Computacion, La Canada Almeria (Spain); Rubio, F.R.; Lara, P.J.; Arahal, M.R.; Camacho, E.F.; Lopez, M. [Universidad de Sevilla, Dept. de Ingenieria de Sistemas y Automatica, Sevilla (Spain); Valverde, A. [Plataforma Solar de Almeria (PSA-CIEMAT), Tabernas (Almeria) (Spain)

    2004-07-01

    This paper presents the development of a simplified and automatic heliostat positioning offset correction control system using artificial vision techniques and common CCD devices. The heliostats of a solar power plant reflect solar radiation onto a receiver (in this case, a volumetric receiver) placed at the top of a tower in order to provide a desired energy flux distribution correlated with the coolant flow (in this case air mass flow) through the receiver, usually in an open loop control configuration. There exist error sources that increase the complexity of the control system, some of which are systematic ones, mainly due to tolerances, wrong mirror facets alignment (optical errors), errors due to the approximations made when calculating the solar position, etc., that produce errors (offsets) in the heliostat orientation (aiming point). The approximation adopted in this paper is based on the use of a B/W CCD camera to correct these deviations in an automatic way imitating the same procedure followed by the operators. The obtained images are used to estimate the distance between the sunbeam centroid projected by the heliostats and a target placed on the tower, this distance thus is used for low accuracy offset correction purposes. Basic threshold-based image processing techniques are used for automatic correction. (Author)

  18. AutoSync : Automatic duty-cycle control for synchronous low-power listening

    DEFF Research Database (Denmark)

    Hansen, Morten Tranberg; Kusy, Branislav; Jurdak, Raja;

    2012-01-01

    resources doing idle listening. This problem is particularly exacerbated in multi-radio networks where majority of data comes through the most reliable radio and the duty cycles of other radios could be reduced. We address this issue in AutoSync, a protocol that combines synchronous LPL with automatic...

  19. Photoresponsive carbohydrate-based giant surfactants: automatic vertical alignment of nematic liquid crystal for the remote-controllable optical device.

    Science.gov (United States)

    Kim, Dae-Yoon; Lee, Sang-A; Kang, Dong-Gue; Park, Minwook; Choi, Yu-Jin; Jeong, Kwang-Un

    2015-03-25

    Photoresponsive carbohydrate-based giant surfactants (abbreviated as CELAnD-OH) were specifically designed and synthesized for the automatic vertical alignment (VA) layer of nematic (N) liquid crystal (LC), which can be applied for the fabrication of remote-controllable optical devices. Without the conventional polymer-based LC alignment process, a perfect VA layer was automatically constructed by directly adding the 0.1 wt % CELA1D-OH in the N-LC media. The programmed CELA1D-OH giant surfactants in the N-LC media gradually diffused onto the substrates of LC cell and self-assembled to the expanded monolayer structure, which can provide enough empty spaces for N-LC molecules to crawl into the empty zones for the construction of VA layer. On the other hand, the CELA3D-OH giant surfactants forming the condensed monolayer structure on the substrates exhibited a planar alignment (PA) rather than a VA. Upon tuning the wavelength of light, the N-LC alignments were reversibly switched between VA and PA in the remote-controllable LC optical devices. Based on the experimental results, it was realized that understanding the interactions between N-LC molecules and amphiphilic giant surfactants is critical to design the suitable materials for the automatic LC alignment.

  20. Automatic registration of geometric distortions in satellite images based on control points

    International Nuclear Information System (INIS)

    This paper presents an automatic registration scheme to register geometric distortion in satellite images; A novel feature based matching scheme is proposed which establishes correspondence between the corner points in the reference and target images either by correlating the intensity values around a circular neighborhood of these corner points or by exploiting the relative orientation of lines connecting these corner points. Affine transformation model is used to estimate transformation parameters. Re-sampling is carried out by nearest neighborhood interpolation. The registration process is automatic and can efficiently serve as preprocessing stage for multitemporal analysis, image fusion, image mosaicking and change detection. The effectiveness of the algorithm has been verified by an intensive experiment on a large number of real images. Experimental results reveal high supremacy of the proposed registration method. (author)

  1. The control of automatic imitation based on bottom-up and top-down cues to animacy: Insights from brain and behavior

    NARCIS (Netherlands)

    Klapper, A.P.; Ramsey, R.; Wigboldus, D.H.J.; Cross, E.S.

    2014-01-01

    Humans automatically imitate other people's actions during social interactions, building rapport and social closeness in the process. Although the behavioral consequences and neural correlates of imitation have been studied extensively, little is known about the neural mechanisms that control imitat

  2. 玉米胚芽油厂自动化控制技术的应用%Application of automatic control in corn germ oil plant

    Institute of Scientific and Technical Information of China (English)

    崔宝贵

    2012-01-01

    The scope,characteristics,basic status and the development in recent years of automatic control in corn germ oil plant was introduced.The functions of automatic control in deodorization,alkali refining and decoloration were analyzed.The difference between process with or without automatic control was compared.The importance of cooperate between technicians of both in production and automatic control during design and management was emphasized.%介绍了玉米胚芽油厂自动化控制的范围、特点、基本状况和近年的发展,分析了自动化在脱臭、碱炼、脱色的作用,对比了自动化前后的差别。强调了油脂专业与自动化控制人员在设计、管理中的作用与配合。

  3. Prediction of extubation outcome: a randomised, controlled trial with automatic tube compensation vs. pressure support ventilation

    OpenAIRE

    Cohen, Jonathan; Shapiro, Maury; Grozovski, Elad; Fox, Ben; Lev, Shaul; Singer, Pierre

    2009-01-01

    Introduction Tolerance of a spontaneous breathing trial is an evidence-based strategy to predict successful weaning from mechanical ventilation. Some patients may not tolerate the trial because of the respiratory load imposed by the endotracheal tube, so varying levels of respiratory support are widely used during the trial. Automatic tube compensation (ATC), specifically developed to overcome the imposed work of breathing because of artificial airways, appears ideally suited for the weaning ...

  4. A perception system for accurate automatic control of an articulated bus

    OpenAIRE

    Salinas, Carlota; Montes, Héctor; Armada, Manuel

    2010-01-01

    This paper describes the perception system for an automatic articulated bus where an accurate tracking trajectory is desired. Among the most promising transport infrastructures of the autonomous or semi-autonomous transportation systems, the articulated bus is an interesting low cost and friendly option. This platform involves a mobile vehicle and a private circuit inside CSIC premises. The perception system, presented in this work, based on 2D laser scanner as a prime sensor generates local ...

  5. Research methodology simplification for teaching purposes illustrated by clutch automatic control device testing

    Science.gov (United States)

    Wojs, J.

    2016-09-01

    The paper proves that simplified, shorter examination of an object, feasible in laboratory classes, can produce results similar to those reached in scientific investigation of the device using extensive equipment. A thorough investigation of an object, an automatic clutch device in this case, enabled identifying the magnitudes that most significantly affect its operation. The knowledge of these most sensitive magnitudes allows focusing in the teaching process on simplified measurement of only selected magnitudes and verifying the given object in the positive or negative.

  6. Automatic Method for Controlling the Iodine Adsorption Number in Carbon Black Oil Furnaces

    OpenAIRE

    Zečević, N.

    2008-01-01

    There are numerous of different inlet process factors in carbon black oil furnaces which must be continuously and automatically adjusted, due to stable quality of final product. The most important six inlet process factors in carbon black oil-furnaces are:1. volume flow of process air for combustion2. temperature of process air for combustion3. volume flow of natural gas for insurance the necessary heat for thermal reaction of conversionthe hydrocarbon oil feedstock in oil-furnace carbon blac...

  7. PLC自动控制系统可靠性提升研究%Discussion on the Reliability Improvement of Plc Automatic Control System

    Institute of Scientific and Technical Information of China (English)

    赵聪

    2015-01-01

    随着我国工业快速发展,各种自动化系统也在不断得以运用与完善,PLC自动控制系统结合了可编程控制器和继电器控制器的优点,形成一套完整的、自动化的控制系统。PLC自动控制系统由于在数据传输以及硬件设备使用的过程中易出错,从而降低PLC自动控制系统的可靠性,因此本文就如何提升PLC自动控制系统的可靠性展开论述。%Along with the fast development of industry in our country,all kinds of automatic systems also have continuous improvement and application,PLC automatic control system combined the advantages of programming controller and a relay controller,formed a complete set of automatic control system. Because PLC automatic control system in the process of data transmission and hardware using process tends to be wrong,thus reducing the reliability of PLC automatic control system. This paper discussed how to enhance the reliability of PLC automatic control system..

  8. Differences in semantic category priming in the left and right cerebral hemispheres under automatic and controlled processing conditions.

    Science.gov (United States)

    Collins, M

    1999-08-01

    The contribution of each cerebral hemisphere to the generation of semantic category meanings at automatic and strategic levels of processing was investigated in a priming experiment where prime and target words were independently projected to the left or right visual fields (LVF or RVF). Non-associated category exemplars were employed as related pairs in a lexical decision task and presented in two experimental conditions. The first condition was designed to elicit automatic processing, so related pairs comprised 20% of the positive set, stimulus pairs were temporally separated by a stimulus onset asynchrony (SOA) of 250 ms, and there was no allusion to the presence of related pairs in the instructions to subjects. The second condition, designed to invoke controlled processing, incorporated a relatedness proportion of 50%, stimulus pairs separated by an SOA of 750 ms, and instructions which informed subjects of the presence and use of category exemplar pairs in the stimulus set. In the first condition, a prime directed to either visual field facilitated responses to categorically related targets subsequently projected to the RVF, while in the second condition a prime directed to either visual field facilitated responses to related targets projected to the LVF. The facilitation effects obtained in both conditions appeared to reflect automatic processes, while strategic processes were invoked in the left, but not the right hemisphere in the second condition. The results suggest that both hemispheres have automatic access to semantic category meanings, although the timecourse of activation of semantic category meanings is slower in the right hemisphere than in the left.

  9. Fuzzy control on automatic frequency tracking of ultrasonic vibration system with high power and high quality factor Q

    Institute of Scientific and Technical Information of China (English)

    ZHU Wu; ZHANG Jia-min; LIU Hong-li; MENG Feng-feng; ZHANG Zhi-ming

    2009-01-01

    In order to realize automatic tracking drift of resonance frequency of ultrasonic vibration system with high power and high quality factor Q, adaptive fuzzy control was studied with a self-fabricated ultrasonic plastic welding machine. At first, relations between amplitude of vibration and frequency as well as main loop current and amplitude of vibration were analyzed. From this analysis, we deduced that frequency tracking process of the vibration system can be concluded as an optimizing problem of one dimensional fluctuant extremum of main loop current in vibration system. Then a method of self-optimizing fuzzy control, used for the realization of automatic frequency tracking in vibration system, is presented on the basis of self-optimizing adaptive control approach and fuzzy control approach. The result of experiments shows that the fuzzy self-optimizing method can solve the problem of tracking frequency drift very well. Response time of tracking in the system is less than 50 ms, which basically meets the requirements of frequency tracking in ultrasonic plastic welding machine.

  10. Application of remote monitoring and automatic control system using neural network for small wastewater treatment plants in Korea.

    Science.gov (United States)

    Lee, H; Lee, K M; Park, C H; Park, Y H

    2005-01-01

    For this study, an automatic control system has been developed by using a neural network and internet-based remote monitoring system for efficient operation of plants that have a serious variance of influent loading and have difficulties in appropriate maintenance, just like small wastewater treatment plants in Korea. In the control algorithm, ORP was used as the main sensor for control. At the point where the ORP value was judged to reach the "nitrate knee" of denitrification and phosphorus release, ORP indicated the state of lower saturation read by the neural network and then changed the operating condition from the reduction state to the oxidation state. For example, if ORP indicates the state of higher saturation at the point of "nitrogen breakpoint" or "ammonia valley" of nitrification, the neural network reads it and cuts off the oxygen supply and mixing. The dORP data have been used as one of the main input for the neural network. After the operation of lab-scale cyclic aeration process using an automatic control system, it has been found that regardless of loading variance, more than 95% of organic matters and more than 60% of nitrogen and phosphorus have been removed. Assuming that an internet-connected computer and a basic web browser are available, this study has developed a remote monitoring system that can monitor the operating status of small plants or any troubles with them. PMID:16104428

  11. Psilocybin-induced deficits in automatic and controlled inhibition are attenuated by ketanserin in healthy human volunteers.

    Science.gov (United States)

    Quednow, Boris B; Kometer, Michael; Geyer, Mark A; Vollenweider, Franz X

    2012-02-01

    The serotonin-2A receptor (5-HT(2A)R) has been implicated in the pathogenesis of schizophrenia and related inhibitory gating and behavioral inhibition deficits of schizophrenia patients. The hallucinogen psilocybin disrupts automatic forms of sensorimotor gating and response inhibition in humans, but it is unclear so far whether the 5-HT(2A)R or 5-HT(1A)R agonist properties of its bioactive metabolite psilocin account for these effects. Thus, we investigated whether psilocybin-induced deficits in automatic and controlled inhibition in healthy humans could be attenuated by the 5-HT(2A/2C)R antagonist ketanserin. A total of 16 healthy participants received placebo, ketanserin (40 mg p.o.), psilocybin (260 μg/kg p.o.), or psilocybin plus ketanserin in a double-blind, randomized, and counterbalanced order. Sensorimotor gating was measured by prepulse inhibition (PPI) of the acoustic startle response. The effects on psychopathological core dimensions and behavioral inhibition were assessed by the altered states of consciousness questionnaire (5D-ASC), and the Color-Word Stroop Test. Psilocybin decreased PPI at short lead intervals (30 ms), increased all 5D-ASC scores, and selectively increased errors in the interference condition of the Stroop Test. Stroop interference and Stroop effect of the response latencies were increased under psilocybin as well. Psilocybin-induced alterations were attenuated by ketanserin pretreatment, whereas ketanserin alone had no significant effects. These findings suggest that the disrupting effects of psilocybin on automatic and controlled inhibition processes are attributable to 5-HT(2A)R stimulation. Sensorimotor gating and attentional control deficits of schizophrenia patients might be due to changes within the 5-HT(2A)R system. PMID:21956447

  12. Psilocybin-induced deficits in automatic and controlled inhibition are attenuated by ketanserin in healthy human volunteers.

    Science.gov (United States)

    Quednow, Boris B; Kometer, Michael; Geyer, Mark A; Vollenweider, Franz X

    2012-02-01

    The serotonin-2A receptor (5-HT(2A)R) has been implicated in the pathogenesis of schizophrenia and related inhibitory gating and behavioral inhibition deficits of schizophrenia patients. The hallucinogen psilocybin disrupts automatic forms of sensorimotor gating and response inhibition in humans, but it is unclear so far whether the 5-HT(2A)R or 5-HT(1A)R agonist properties of its bioactive metabolite psilocin account for these effects. Thus, we investigated whether psilocybin-induced deficits in automatic and controlled inhibition in healthy humans could be attenuated by the 5-HT(2A/2C)R antagonist ketanserin. A total of 16 healthy participants received placebo, ketanserin (40 mg p.o.), psilocybin (260 μg/kg p.o.), or psilocybin plus ketanserin in a double-blind, randomized, and counterbalanced order. Sensorimotor gating was measured by prepulse inhibition (PPI) of the acoustic startle response. The effects on psychopathological core dimensions and behavioral inhibition were assessed by the altered states of consciousness questionnaire (5D-ASC), and the Color-Word Stroop Test. Psilocybin decreased PPI at short lead intervals (30 ms), increased all 5D-ASC scores, and selectively increased errors in the interference condition of the Stroop Test. Stroop interference and Stroop effect of the response latencies were increased under psilocybin as well. Psilocybin-induced alterations were attenuated by ketanserin pretreatment, whereas ketanserin alone had no significant effects. These findings suggest that the disrupting effects of psilocybin on automatic and controlled inhibition processes are attributable to 5-HT(2A)R stimulation. Sensorimotor gating and attentional control deficits of schizophrenia patients might be due to changes within the 5-HT(2A)R system.

  13. RISK DECREASE PROBLEM WITH MAKING ERRORS IN ACTIVITY OF OPERATORS DEALING WITH AUTOMATIC CONTROL SYSTEMS OF GAS-DISTRIBUTION STATIONS

    Directory of Open Access Journals (Sweden)

    V. V. Egorov

    2011-01-01

    Full Text Available The paper contains an analysis of specific features pertaining to the activity of operators dealing with automatic control systems of gas-distribution stations. The professional operator’s activity is presented in the form of the developed data model. Possible conceptual approaches to the research are analyzed in the paper. The paper describes an author’s approach to studying a risk decrease problem in the activity of operators on the basis of the analytical research results. Technology for obtaining  research results is cited in the paper. 

  14. AUTOMATIC CONTROL SYSTEM FOR THE HEAT PUMP EMBEDDED IN THE MILK PASTEURIZATION AND COOLING INSTALLATION, part II

    Directory of Open Access Journals (Sweden)

    Sit M.L.

    2013-04-01

    Full Text Available The goal of the present work is to elaborate the scheme of the disturbance compensation system, which is influencing the level of refrigerant consumption in evaporators and gas coolers of the heat pump embedded in the milk pasteurization and cooling installation, as well as, to design the automatic control system for the heat-exchanger with two output parameters – the water temperature at the outlet of the primary and secondary heat-carrying agent circuits by adjusting the consumption level in the secondary heat-carrying agent circuit and by adjusting the heat exchange surface area. System structures are based on principles of the coordinated control and the multidimensional systems control. The proposed structural scheme of the coordinated system for control of the consumption in evaporators, both water heating and cooling segments, is more accurate in transient processes than alternative systems of non-integrated control of the working agent consumption in each evaporator. The heat exchanger control system with two controls controlling segments (controlling the heat exchange surface area and controlling the consumption level in the secondary coolant circuit has proven to have good transient characteristics.

  15. On the meaning of meaning when being mean: commentary on Berkowitz's "on the consideration of automatic as well as controlled psychological processes in aggression".

    Science.gov (United States)

    Dodge, Kenneth A

    2008-01-01

    Berkowitz (this issue) makes a cogent case for his cognitive neo-associationist (CNA) model that some aggressive behaviors occur automatically, emotionally, and through conditioned association with other stimuli. He also proposes that they can occur without "processing," that is, without meaning. He contrasts his position with that of social information processing (SIP) models, which he casts as positing only controlled processing mechanisms for aggressive behavior. However, both CNA and SIP models posit automatic as well as controlled processes in aggressive behavior. Most aggressive behaviors occur through automatic processes, which are nonetheless rule governed. SIP models differ from the CNA model in asserting the essential role of meaning (often through nonconscious, automatic, and emotional processes) in mediating the link between a stimulus and an angry aggressive behavioral response. PMID:18203196

  16. The control of automatic imitation based on bottom-up and top-down cues to animacy: Insights from brain and behavior

    OpenAIRE

    Klapper, A.P.; Ramsey, R; Wigboldus, D.H.J.; E. S. Cross

    2014-01-01

    Humans automatically imitate other people's actions during social interactions, building rapport and social closeness in the process. Although the behavioral consequences and neural correlates of imitation have been studied extensively, little is known about the neural mechanisms that control imitative tendencies. For example, the degree to which an agent is perceived as human-like influences automatic imitation, but it is not known how perception of animacy influences brain circuits that con...

  17. 废水处理中pH值的PLC自动控制系统%PLC automatic control system of pH value in wastewater treatment.

    Institute of Scientific and Technical Information of China (English)

    李安峰; 张志群; 丁庭华; 王绍堂

    2001-01-01

    The pH value automatic control is a key link in the treatment of industrial wastewater. Based on much literature review, a new PLC automatic control system, suitable for pH value control in the wastewater treatment, is developed with simple structure and good control effect, which offers a practical approach for pH value automatic control in the treatment of industrial wastewater.%pH值自动控制是工业废水处理过程中的关键环节.在查阅大量文献的基础上,研究出一套新的适于污水处理pH值控制的结构简单且控制效果良好的PLC自动控制系统,为工业废水处理的pH值自动控制提供了一条切实可行的途径.

  18. 冷固球团自动控制系统%Automatic Control System of Cold-bound Pellets

    Institute of Scientific and Technical Information of China (English)

    牛秦洲; 廖承业

    2013-01-01

    Introduces the Siemens S7-300 PLC on cold solid pellets application in automatic control system,detailed introduces the cold solid pellet production process,and gives the hardware and software of the control system design scheme,the network structure,PLC program design and configuration monitoring system design.In the cold solid pellets batching processing,for batching accuracy is difficult to control,a kind of based on fuzzy adaptive PID control method was proposed.The system realizes the cold solid pellets process automatic control,since its operation,the actual operation was stable,and the effect was good.%阐述了西门子公司S7-300PLC在冷固球团自动控制系统中的运用,详细介绍了冷固球团生产工艺流程,并给出了控制系统的硬件和软件设计方案,网络结构、PLC程序设计以及组态监控系统的设计.针对冷固球团配料过程中配料精度难以控制的问题,提出一种基于模糊自适应PID控制方法.该系统实现了冷固球团工艺全自动控制,自投产以来,实际运行稳定,效果良好.

  19. Controlled test compiling and programming automatization for the NPP operator training system

    Energy Technology Data Exchange (ETDEWEB)

    Gevorkyan, A.S.; Muradyan, S.G.; Oganesyan, R.A.; Pogosyan, V.Sh.

    1984-01-01

    Problems of control test compiling and programming for the NPP operator training system (OTS) are considered. Types of control questions and answers to them used in the OTS for arrangement of admittance and current control of knowledge are given. A method for control test compiling and programming automation for OTS is described.

  20. Automatic dosage of hydrogen peroxide in solar photo-Fenton plants: Development of a control strategy for efficiency enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Ortega-Gomez, E. [Department of Chemical Engineering, University of Almeria, 04120 Almeria (Spain); CIESOL, Joint Centre of the University of Almeria-CIEMAT, 04120 Almeria (Spain); Moreno Ubeda, J.C. [Department of Language and Computation, University of Almeria, 04120 Almeria (Spain); Alvarez Hervas, J.D. [Department of Language and Computation, University of Almeria, 04120 Almeria (Spain); Department of Language and Computation, University of Sevilla, 41092 Sevilla (Spain); Casas Lopez, J.L.; Santos-Juanes Jorda, L. [Department of Chemical Engineering, University of Almeria, 04120 Almeria (Spain); CIESOL, Joint Centre of the University of Almeria-CIEMAT, 04120 Almeria (Spain); Sanchez Perez, J.A., E-mail: jsanchez@ual.es [Department of Chemical Engineering, University of Almeria, 04120 Almeria (Spain); CIESOL, Joint Centre of the University of Almeria-CIEMAT, 04120 Almeria (Spain)

    2012-10-30

    Highlights: Black-Right-Pointing-Pointer Dissolved oxygen monitoring is used for automatic dosage of H{sub 2}O{sub 2} in photo-Fenton. Black-Right-Pointing-Pointer PI with anti-windup minimises H{sub 2}O{sub 2} consumption. Black-Right-Pointing-Pointer The H{sub 2}O{sub 2} consumption was reduced up to 50% with respect to manual addition strategies. Black-Right-Pointing-Pointer Appropriate H{sub 2}O{sub 2} dosage is achieved by PI with anti-windup under disturbances. - Abstract: The solar photo-Fenton process is widely used for the elimination of pollutants in aqueous effluent and, as such, is amply cited in the literature. In this process, hydrogen peroxide represents the highest operational cost. Up until now, manual dosing of H{sub 2}O{sub 2} has led to low process performance. Consequently, there is a need to automate the hydrogen peroxide dosage for use in industrial applications. As it has been demonstrated that a relationship exists between dissolved oxygen (DO) concentration and hydrogen peroxide consumption, DO can be used as a variable in optimising the hydrogen peroxide dosage. For this purpose, a model was experimentally obtained linking the dynamic behaviour of DO to hydrogen peroxide consumption. Following this, a control system was developed based on this model. This control system - a proportional and integral controller (PI) with an anti-windup mechanism - has been tested experimentally. The assays were carried out in a pilot plant under sunlight conditions and with paracetamol used as the model pollutant. In comparison with non-assisted addition methods (a sole initial or continuous addition), a decrease of 50% in hydrogen peroxide consumption was achieved when the automatic controller was used, driving an economic saving and an improvement in process efficiency.

  1. Anti-sway/position control technology of hoist cranes for automatic guided systems; Hanso no jidoka ni kiyosuru hoist crane no furedome ichigime seigyo gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    Nomura, M.; Hakamada, Y.; Saiki, H. [Meidensha Corp., Tokyo (Japan)

    1997-06-30

    The automatic control system of hoist cranes for automatic guided systems was developed which is composed of separated anti-sway nd position control. This system is equipped with a control equipment, vector control inverter, and induction motor for traversing and traveling. The system detects trolley position, wire length and sway angle, computes velocity commands by the control equipment for exact stop at a target position, and controls velocity by the vector control inverter. The system applies acceleration feedback to anti-sway, and makes it possible to obtain non-vibrational velocity response of loads corresponding to velocity commands for position control. The position control also generates the velocity command harmonizing a stop position and the minimum value of a quadratic curve, to reduce vibration energy generated during acceleration and deceleration. As the experiment result, the anti-sway control could achieve smooth stop with no sway at a target position. 8 refs., 7 figs.

  2. Self-tuning control applied to turbogenerator AVRs [Automatic Voltage Regulators

    Energy Technology Data Exchange (ETDEWEB)

    Finch, J.W.; Farsi, M. [Newcastle upon Tyne Univ. (United Kingdom); Zachariah, K.J. [Parsons Power Generation Systems Ltd., Newcastle upon Tyne (United Kingdom)

    1996-09-01

    Results from a research and development programme devoted to turbogenerator control are described. Digital self-tuning controllers are covered, although fixed parameter controllers have also been considered. Simulations and test on laboratory scale machines have been accomplished successfully, with a prototype self-tuning controller being manufactured. A set of typical results is given, covering responses to normal set point changes and fault dynamics. These new controllers are shown to have good potential for practical application. (author)

  3. Automatic sequences

    CERN Document Server

    Haeseler, Friedrich

    2003-01-01

    Automatic sequences are sequences which are produced by a finite automaton. Although they are not random they may look as being random. They are complicated, in the sense of not being not ultimately periodic, they may look rather complicated, in the sense that it may not be easy to name the rule by which the sequence is generated, however there exists a rule which generates the sequence. The concept automatic sequences has special applications in algebra, number theory, finite automata and formal languages, combinatorics on words. The text deals with different aspects of automatic sequences, in particular:· a general introduction to automatic sequences· the basic (combinatorial) properties of automatic sequences· the algebraic approach to automatic sequences· geometric objects related to automatic sequences.

  4. Automatic control of gaseous effluents emitted through the RP-10 reactor chimney; Control automatico de efluentes gaseosos emitidos por chimenea en el reactor RP-10

    Energy Technology Data Exchange (ETDEWEB)

    Castillo Y, Walter; Anaya G, Olgger; Ovalle S, Edgar [Instituto Peruano de Energia Nuclear, Lima (Peru)

    2002-07-01

    The ventilation system of the reactor, has a way in which should work in the event of a nuclear accident. Formerly the change to this emergency way was carried out in manual form manual, when the radioprotection official, detected during the control of the places that the radiation levels had been overcome, informing to the responsible of the control room, so that they change the ventilation system to the emergency way. Considering that this procedure was not the most appropriate for the retarded time in taking the measures correctives, we are decided to carry out in the design and implementation of an automatic system that it acquires the data of the radiation levels of the effluents that are evacuating to the environment, of the SEM1000 equipment and when the reference level is overcome, automatically the designed system will change the operation way the ventilation system to emergency, closing the exit to the exterior and putting it in the recirculation way, for it is used a micro controller PIC 16F877. On the other hand it has been taken to the control room the sign of the SEM1000, as a repeater with the same characteristics of the presentation of data of this equipment. (author)

  5. HVAC System Automatic Controls and Indoor Air Quality in Schools. Technical Bulletin.

    Science.gov (United States)

    Wheeler, Arthur E.

    Fans, motors, coils, and other control components enable a heating, ventilating, and air-conditioning (HVAC) system to function smoothly. An explanation of these control components and how they make school HVAC systems work is provided. Different systems may be compared by counting the number of controlled devices that are required. Control…

  6. Strategies for energy saving in buildings by means of automatic control; Estrategias de ahorro de energia en inmuebles mediante el control automatico

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Trujillo, Oscar [Johnson Controls de Mexico S. A. de C. V., Mexico, D. F. (Mexico)

    1998-12-31

    In this paper some of the measures and strategies for energy saving that can be applied in different types of buildings, mainly in hotels and office buildings, are presented. The proposed actions are accomplished with the aid of the automatic control equipment and the operation and/or maintenance personnel that supervises and establishes the control parameters of each one of the strategies than are focused to the appropriate utilization of the electric energy. [Espanol] En este documento se presentan algunas de las medidas y estrategias de ahorro de energia que pueden ser aplicadas en diferentes tipos de inmuebles, principalmente en hoteles y en edificios de oficinas. Las acciones propuestas son realizadas con la ayuda del equipo de control automatico y del personal de operacion y/o mantenimiento quien supervisa y establece los parametros de control de cada una de las estrategias que son destinadas a la buena utilizacion de la energia electrica.

  7. Development of motion controller and its application in automatic TIG welding system

    Institute of Scientific and Technical Information of China (English)

    董春; 徐文立; 杨耕; 富历新

    2003-01-01

    To develop a control system of cantilever arm for barrels welding, a motion controller has been developed to fit the welding procedure. The main research fields of the controller are: (1) finding effective measures to protect the controller against interferences; (2) decreasing welding current gradually in order to alleviate arc craters which are harmful to seam forming and welding quality; (3) planning the arm velocity to minimize the influence of the arm swing on arc length regulator; (4) adopting adaptive control algorithm with PD feedback and velocity feed-forward to reduce the influence of system inertia and velocity planning on the system transient performance.

  8. Virtual Clutch Controller for Clutch-to-Clutch Shifts in Planetary-Type Automatic Transmission

    Directory of Open Access Journals (Sweden)

    Yunjiang Cheng

    2015-01-01

    Full Text Available It is known that the shift processes of the four types of clutch-to-clutch shifts can theoretically be divided into two phases which are torque phase and inertia phase, but the execution orders are different. Two virtual clutch controllers are designed with the same eight states which include all control processes for these shifts. An equivalent method is proposed so that AT can be controlled just like DCT by adopting the torque ratios of oncoming clutch and offgoing clutch of each gear. The powertrain system model and the shift controller are established on Matlab/Simulink platform. The clutch-to-clutch shift processes have been studied based on the virtual clutch controller by software-in-the-loop simulations. Some typical problems in the clutch-to-clutch shift control are discussed and several control methods are compared to solve these problems.

  9. Wind power integration into the automatic generation control of power systems with large-scale wind power

    Directory of Open Access Journals (Sweden)

    Abdul Basit

    2014-10-01

    Full Text Available Transmission system operators have an increased interest in the active participation of wind power plants (WPP in the power balance control of power systems with large wind power penetration. The emphasis in this study is on the integration of WPPs into the automatic generation control (AGC of the power system. The present paper proposes a coordinated control strategy for the AGC between combined heat and power plants (CHPs and WPPs to enhance the security and the reliability of a power system operation in the case of a large wind power penetration. The proposed strategy, described and exemplified for the future Danish power system, takes the hour-ahead regulating power plan for generation and power exchange with neighbouring power systems into account. The performance of the proposed strategy for coordinated secondary control is assessed and discussed by means of simulations for different possible future scenarios, when wind power production in the power system is high and conventional production from CHPs is at a minimum level. The investigation results of the proposed control strategy have shown that the WPPs can actively help the AGC, and reduce the real-time power imbalance in the power system, by down regulating their production when CHPs are unable to provide the required response.

  10. MATHEMATICAL MODEL OF TRANSIENT PROCESSES PERTAIN-ING TO THREE-IMPULSE SYSTEM FOR AUTOMATIC CONTROL OF STEAM GENERATOR WATER SUPPLY ON LOAD RELIEF

    Directory of Open Access Journals (Sweden)

    G. T. Kulakov

    2014-01-01

    Full Text Available The paper analyzes an operation of the standard three-impulse automatic control system (ACS for steam generator water supply. Mathematical model for checking its operational ability on load relief has been developed in the paper and this model makes it possible to determine maximum deviations of water level without execution of actual tests and any corrections in the plants for starting-up of technological protection  systems in accordance with water level in the drum.  The paper reveals reasons of static regulation errors while solving problems of internal and external distortions caused by expenditure of over-heated steam in the standard automatic control system. An actual significance of modernization pertaining to automatic control system for steam generator water supply has been substantiated in the paper.

  11. 某型电台短波频段自动控制通信设计%Communication Design of Automatic Control for a Radio Wave Frequency Band

    Institute of Scientific and Technical Information of China (English)

    孙明亮; 雷坤; 吴彬彬

    2014-01-01

    该文从整体设计的思路到自动控制通信主要内容以及自动控制通信实现的具体流程,阐述了作为新一代短波电台独有的短波频段自动控制通信新技术的设计过程。%This paper to the automatic control of main contents of communication and the specific process of communication to achieve automatic control from the overall design ideas, design is introduced as a new generation of short wave frequency band shortwave radio unique automatic control of new communications technologies.

  12. Development of an automatic subsea blowout preventer stack control system using PLC based SCADA.

    Science.gov (United States)

    Cai, Baoping; Liu, Yonghong; Liu, Zengkai; Wang, Fei; Tian, Xiaojie; Zhang, Yanzhen

    2012-01-01

    An extremely reliable remote control system for subsea blowout preventer stack is developed based on the off-the-shelf triple modular redundancy system. To meet a high reliability requirement, various redundancy techniques such as controller redundancy, bus redundancy and network redundancy are used to design the system hardware architecture. The control logic, human-machine interface graphical design and redundant databases are developed by using the off-the-shelf software. A series of experiments were performed in laboratory to test the subsea blowout preventer stack control system. The results showed that the tested subsea blowout preventer functions could be executed successfully. For the faults of programmable logic controllers, discrete input groups and analog input groups, the control system could give correct alarms in the human-machine interface. PMID:21889767

  13. Remotely controlled semi-automatic welding of two revolution symmetrical pieces

    International Nuclear Information System (INIS)

    The welding is controlled from a control station situated at some distance from the welding zone. The welding parameters are fixed before the welding pass by an operator from values furnished by a memory in which the appropriate parameters are stored. After control of these parameters the welding operation is initiated. The welding operation is constantly observed on a remotely placed screen. The welding parameters may be adjusted by the operator in accordance with the image observed. These modifications are controlled by comparison with the memory content

  14. The effects of total sleep deprivation on semantic priming: event-related potential evidence for automatic and controlled processing strategies.

    Science.gov (United States)

    López Zunini, Rocío; Muller-Gass, Alexandra; Campbell, Kenneth

    2014-02-01

    There is general consensus that performance on a number of cognitive tasks deteriorates following total sleep deprivation. At times, however, subjects manage to maintain performance. This may be because of an ability to switch cognitive strategies including the exertion of compensatory effort. The present study examines the effects of total sleep deprivation on a semantic word priming task. Word priming is unique because it can be carried out using different strategies involving either automatic, effortless or controlled, effortful processing. Twelve subjects were presented with word pairs, a prime and a target, that were either highly semantically associated (cat…dog), weakly associated (cow…barn) or unassociated (apple…road). In order to increase the probability of the use of controlled processing following normal sleep, the subject's task was to determine if the target word was semantically related to the prime. Furthermore, the time between the offset of the prime and the onset of the target was relatively long, permitting the use of an effortful, expectancy-predictive strategy. Event-related potentials (ERPs) were recorded from 64 electrode sites. After normal sleep, RTs were faster and accuracy higher to highly associated targets; this performance advantage was also maintained following sleep deprivation. A large negative deflection, the N400, was larger to weakly associated and unassociated targets in both sleep-deprived and normal conditions. The overall N400 was however larger in the normal sleep condition. Moreover, a long-lasting negative slow wave developed between the offset of the prime and the onset of the target. These physiological measures are consistent with the use of an effortful, predictive strategy following normal sleep but an automatic, effortless strategy following total sleep deprivation. A picture priming task was also run. This task benefits less from the use of a predictive strategy. Accordingly, in this task, ERPs following the

  15. Automatic Tuning Of Proportional-Integral-Derivative (Pid Controller Using Particle Swarm Optimization (Pso Algorithm

    Directory of Open Access Journals (Sweden)

    S. J. Bassi

    2011-10-01

    Full Text Available The proportional-integral-derivative (PID controllers are the most popular controllers used in industry because of their remarkable effectiveness, simplicity of implementation and broad applicability. However, manual tuning of these controllers is time consuming, tedious and generally lead to poor performance. This tuning which is application specific also deteriorates with time as a result of plant parameter changes. This paper presents an artificial intelligence (AI method of particle swarm optimization (PSO algorithm for tuning the optimal proportional-integral derivative (PID controller parameters for industrial processes. This approach has superior features, including easy implementation, stable convergence characteristic and good computational efficiency over the conventional methods. Ziegler- Nichols, tuning method was applied in the PID tuning and results were compared with the PSO-Based PID for optimum control. Simulation results are presented to show that the PSO-Based optimized PID controller is capable of providing an improved closed-loop performance over the Ziegler- Nichols tuned PID controller Parameters. Compared to the heuristic PID tuning method of Ziegler-Nichols, the proposed method was more efficient in improving the step response characteristics such as, reducing the steady-states error; rise time, settling time and maximum overshoot in speed control of DC motor.

  16. A new portable device for automatic controlled-gradient cryopreservation of blood mononuclear cells

    DEFF Research Database (Denmark)

    Hviid, L; Albeck, G; Hansen, B;

    1993-01-01

    Protection of the functional integrity of mononuclear cells stored in liquid N2 requires careful control of the freezing procedure. Consequently, optimal quality of cryopreserved cells is usually assured by freezing according to a specified time-temperature gradient generated by computer-controll......Protection of the functional integrity of mononuclear cells stored in liquid N2 requires careful control of the freezing procedure. Consequently, optimal quality of cryopreserved cells is usually assured by freezing according to a specified time-temperature gradient generated by computer......-controlled freezing devices. While such equipment offers large capacity and secures maximum survival and functional integrity of the lymphocytes upon thawing, it is quite costly and strictly stationary. We have previously developed and tested an alternative, manual device for controlled-gradient lymphocyte freezing...

  17. Monitoring and Automatic Control for Ship Power Plants Based Logical Algorithms

    Directory of Open Access Journals (Sweden)

    Mahmoud Mohammad Salem Al-suod

    2014-12-01

    Full Text Available Controlling power station systems with diesel engines is vital issue. Algorithms of microprocessors are developed to be used in the control unit of this type of power station systems. Such Algorithms are built in a logic form, and then the control functions are derived using logic functions. Analyzing the contents of the received logic signals allows us to overcome structural redundancy of the systems. Monitor the network parameter is very important to protect the devices used in the power station systems. In this paper automated controller is developed using microprocessor algorithms to view and control the parameters of the system devices such as generator, synchronizers, and load sharers on-line, this will help in improving the system to be fast, reliable and more accurate. This paper proposes an implementation of a subsequent optimization for structural and algorithmic blocks of microprocessor systems automation of ship power plants.

  18. Realization of automatic gauge control function in TCS system%厚度自动控制功能在TCS系统中的实现

    Institute of Scientific and Technical Information of China (English)

    王业涛

    2016-01-01

    This project mainly studies the automatic gauge control function, mainly introduces the micro tension control function, the stiffness compensation technology and the realization of the automatic calibration process.This project has a good value for promotion.%本项目主要针对TCS系统中的厚度自动调整功能进行了仔细研究,主要介绍了微张力控制功能、刚度补偿技术以及自动校准过程的实现等,具有良好的推广价值。

  19. On the Application of MATLAB to the Course of Automatic Control Theory%MATLAB在自动控制理论课程中的应用

    Institute of Scientific and Technical Information of China (English)

    刘丽丽

    2011-01-01

    本文介绍了MATLAB软件在自动控制原理上的应用,通过实例分析,应用MATLAB软件进行计算机辅助分析,对于自动控制原理的学习有很大的帮助。%This paper introduces the application of MATLAB software to the course of Automatic Control Theory.Practical examples prove it of great help for the learning of automatic control theory by applying MATLAB software to implement computer-aided analysis.

  20. Development of Integration Algorithms for Vision/Force Robot Control with Automatic Decision System

    OpenAIRE

    Bdiwi, Mohamad

    2014-01-01

    In advanced robot applications, the challenge today is that the robot should perform different successive subtasks to achieve one or more complicated tasks similar to human. Hence, this kind of tasks required to combine different kind of sensors in order to get full information about the work environment. However, from the point of view of control, more sensors mean more possibilities for the structure of the control system. As shown previously, vision and force sensors are the most common ex...

  1. Impact on energy conservation of automatic control systems utilization in the US pulp and paper industry

    Energy Technology Data Exchange (ETDEWEB)

    Fam, S.S.

    1978-01-01

    This study is concerned with the energy and other resource benefits resulting from the computerized automation of processes in the US pulp and paper industry. The primary objectives were to characterize the state of the art of computer controls in the industry and to pinpoint the problem areas that limit their further use. The study lasted approximately 4 months. An exhaustive survey of all the possible technologies in use, or under development, was not possible. The main conclusions are that the pulping and recovery operations offer the greatest potential for reducing energy use by computer control, and that effective hierarchical control at the plant level requires the integration of these operations into one or more control loops. No control system has been found that provides reliable, fully automated control of recovery boilers for an extended period of time. The total technical potential for fuel savings was estimated at 0.2 quadrillion Btu's a year, or the equivalent of 94,000 barrels of oil per day.

  2. Automatic Control System for the High Pressure CdTe Crystal Growth Furnace

    Directory of Open Access Journals (Sweden)

    Petr Praus

    2006-08-01

    Full Text Available CdTe and (CdZnTe bulk single crystals have been widely used as substrates for MBE and LPE epitaxy of infrared (HgCdTe as well as gamma- and X-ray detectors. The Cd1-xZnxTe (x = 0.04-0.1 single crystals with diameter up to 100 mm and height at most 40 mm were prepared in our laboratory in a vertical arrangement by gradual cooling of the melt (the Vertical Gradient Freezing method. Achievement of excellent crystal quality required full control of Cd pressure during the growth process and application of high Cd pressures (up to 4 bar at growth temperature. An electronic control system was designed to control both temperature and internal pressure of two zones CZT crystal growth furnace by using two high performance PID controllers/setpoint programmers. Two wire current loop serial communication bus was used for the data exchange and computer control of the furnace electronics setup. Control software was written to supervise the crystal growth process and to collect all important data and parameters.

  3. Experimental implementation of automatic 'cycle to cycle' control of a chiral simulated moving bed separation.

    Science.gov (United States)

    Amanullah, Mohammad; Grossmann, Cristian; Mazzotti, Marco; Morari, Manfred; Morbidelli, Massimo

    2007-09-21

    In the absence of a suitable controller, currently simulated moving beds (SMBs) are operated suboptimally to cope with system uncertainties and to guarantee robustness of operation. Recently, we have developed a 'cycle to cycle' optimizing controller that not only makes use of minimal system information, i.e. only the Henry constants and average bed voidage, but also optimizes the process performance and taps the full economic potential of the SMB technology. The experimental implementation of the 'cycle to cycle' optimizing controller had been carried out for achiral separation. For chiral separation however, application of any online controller has not been possible because an appropriate online monitoring system has not been available. This work reports and discusses the first experimental implementation of the 'cycle to cycle' optimizing control for chiral separations. A mixture of guaifenesin enantiomers is separated on Chiralcel OD columns with ethanol as mobile phase in a eight-column four sections laboratory SMB unit. The results show that the controller, although using minimal information about the retention of the two enantiomers, is able to meet product and process specifications, can optimize the process performance, and is capable of rejecting disturbances that may occur during the operation of the SMB plant. PMID:17707852

  4. Real-time piloted simulation of fully automatic guidance and control for rotorcraft nap-of-the-earth (NOE) flight following planned profiles

    Science.gov (United States)

    Clement, Warren F.; Gorder, Pater J.; Jewell, Wayne F.; Coppenbarger, Richard

    1990-01-01

    Developing a single-pilot all-weather NOE capability requires fully automatic NOE navigation and flight control. Innovative guidance and control concepts are being investigated to (1) organize the onboard computer-based storage and real-time updating of NOE terrain profiles and obstacles; (2) define a class of automatic anticipative pursuit guidance algorithms to follow the vertical, lateral, and longitudinal guidance commands; (3) automate a decision-making process for unexpected obstacle avoidance; and (4) provide several rapid response maneuvers. Acquired knowledge from the sensed environment is correlated with the recorded environment which is then used to determine an appropriate evasive maneuver if a nonconformity is observed. This research effort has been evaluated in both fixed-base and moving-base real-time piloted simulations thereby evaluating pilot acceptance of the automated concepts, supervisory override, manual operation, and reengagement of the automatic system.

  5. Nonlinear automatic landing control of unmanned aerial vehicles on moving platforms via a 3D laser radar

    Energy Technology Data Exchange (ETDEWEB)

    Hervas, Jaime Rubio; Tang, Hui [School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore, 639798 (Singapore); Reyhanoglu, Mahmut [Physical Sciences Department, Embry-Riddle Aeronautical University, Daytona Beach, FL 32114 (United States)

    2014-12-10

    This paper presents a motion tracking and control system for automatically landing Unmanned Aerial Vehicles (UAVs) on an oscillating platform using Laser Radar (LADAR) observations. The system itself is assumed to be mounted on a ship deck. A full nonlinear mathematical model is first introduced for the UAV. The ship motion is characterized by a Fourier transform based method which includes a realistic characterization of the sea waves. LADAR observation models are introduced and an algorithm to process those observations for yielding the relative state between the vessel and the UAV is presented, from which the UAV's state relative to an inertial frame can be obtained and used for feedback purposes. A sliding mode control algorithm is derived for tracking a landing trajectory defined by a set of desired waypoints. An extended Kalman filter (EKF) is proposed to account for process and observation noises in the design of a state estimator. The effectiveness of the control algorithm is illustrated through a simulation example.

  6. Nonlinear automatic landing control of unmanned aerial vehicles on moving platforms via a 3D laser radar

    International Nuclear Information System (INIS)

    This paper presents a motion tracking and control system for automatically landing Unmanned Aerial Vehicles (UAVs) on an oscillating platform using Laser Radar (LADAR) observations. The system itself is assumed to be mounted on a ship deck. A full nonlinear mathematical model is first introduced for the UAV. The ship motion is characterized by a Fourier transform based method which includes a realistic characterization of the sea waves. LADAR observation models are introduced and an algorithm to process those observations for yielding the relative state between the vessel and the UAV is presented, from which the UAV's state relative to an inertial frame can be obtained and used for feedback purposes. A sliding mode control algorithm is derived for tracking a landing trajectory defined by a set of desired waypoints. An extended Kalman filter (EKF) is proposed to account for process and observation noises in the design of a state estimator. The effectiveness of the control algorithm is illustrated through a simulation example

  7. Automatic generation control of multi-area power systems with diverse energy sources using Teaching Learning Based Optimization algorithm

    Directory of Open Access Journals (Sweden)

    Rabindra Kumar Sahu

    2016-03-01

    Full Text Available This paper presents the design and analysis of Proportional-Integral-Double Derivative (PIDD controller for Automatic Generation Control (AGC of multi-area power systems with diverse energy sources using Teaching Learning Based Optimization (TLBO algorithm. At first, a two-area reheat thermal power system with appropriate Generation Rate Constraint (GRC is considered. The design problem is formulated as an optimization problem and TLBO is employed to optimize the parameters of the PIDD controller. The superiority of the proposed TLBO based PIDD controller has been demonstrated by comparing the results with recently published optimization technique such as hybrid Firefly Algorithm and Pattern Search (hFA-PS, Firefly Algorithm (FA, Bacteria Foraging Optimization Algorithm (BFOA, Genetic Algorithm (GA and conventional Ziegler Nichols (ZN for the same interconnected power system. Also, the proposed approach has been extended to two-area power system with diverse sources of generation like thermal, hydro, wind and diesel units. The system model includes boiler dynamics, GRC and Governor Dead Band (GDB non-linearity. It is observed from simulation results that the performance of the proposed approach provides better dynamic responses by comparing the results with recently published in the literature. Further, the study is extended to a three unequal-area thermal power system with different controllers in each area and the results are compared with published FA optimized PID controller for the same system under study. Finally, sensitivity analysis is performed by varying the system parameters and operating load conditions in the range of ±25% from their nominal values to test the robustness.

  8. Automaticity of Cognitive Control: Goal Priming in Response-Inhibition Paradigms

    Science.gov (United States)

    Verbruggen, Frederick; Logan, Gordon D.

    2009-01-01

    Response inhibition is a hallmark of cognitive control. An executive system inhibits responses by activating a stop goal when a stop signal is presented. The authors asked whether the stop goal could be primed by task-irrelevant information in stop-signal and go/no-go paradigms. In Experiment 1, the task-irrelevant primes "GO," ###, or "STOP" were…

  9. Potential of controlled traffic farming with automatic guidance on an organic farm in the Netherlands

    NARCIS (Netherlands)

    Vermeulen, G.D.; Mosquera, J.; Wel, van der C.; Klooster, van der A.; Steenhuizen, J.W.

    2007-01-01

    Some organic farms in the Netherlands use RTK-DGPS guidance of machinery over fixed traffic lanes to achieve non-trafficked cropping zones with optimum soil structure. These lanes are not yet used for harvesting and primary tillage. The potential of such a seasonal controlled traffic farming (SCTF)

  10. Automatic tracking of laparoscopic instruments for autonomous control of a cameraman robot.

    Science.gov (United States)

    Amini Khoiy, Keyvan; Mirbagheri, Alireza; Farahmand, Farzam

    2016-06-01

    Background An automated instrument tracking procedure was designed and developed for autonomous control of a cameraman robot during laparoscopic surgery. Material and methods The procedure was based on an innovative marker-free segmentation algorithm for detecting the tip of the surgical instruments in laparoscopic images. A compound measure of Saturation and Value components of HSV color space was incorporated that was enhanced further using the Hue component and some essential characteristics of the instrument segment, e.g., crossing the image boundaries. The procedure was then integrated into the controlling system of the RoboLens cameraman robot, within a triple-thread parallel processing scheme, such that the tip is always kept at the center of the image. Results Assessment of the performance of the system on prerecorded real surgery movies revealed an accuracy rate of 97% for high quality images and about 80% for those suffering from poor lighting and/or blood, water and smoke noises. A reasonably satisfying performance was also observed when employing the system for autonomous control of the robot in a laparoscopic surgery phantom, with a mean time delay of 200ms. Conclusion It was concluded that with further developments, the proposed procedure can provide a practical solution for autonomous control of cameraman robots during laparoscopic surgery operations. PMID:26872883

  11. Automatic pneumatic source-control system for positioning gamma and neutron calibration sources

    International Nuclear Information System (INIS)

    A microcomputer-based source-control system was developed to move gamma and neutron calibration sources into position for sample irradiation. In addition to monitoring interlocks and system status, the computer calculates for gamma sources the time required for a requested exposure at a specified distance. All system use data is stored, and monthly reports are generated

  12. The control of automatic imitation based on bottom-up and top-down cues to animacy: insights from brain and behavior.

    Science.gov (United States)

    Klapper, André; Ramsey, Richard; Wigboldus, Daniël; Cross, Emily S

    2014-11-01

    Humans automatically imitate other people's actions during social interactions, building rapport and social closeness in the process. Although the behavioral consequences and neural correlates of imitation have been studied extensively, little is known about the neural mechanisms that control imitative tendencies. For example, the degree to which an agent is perceived as human-like influences automatic imitation, but it is not known how perception of animacy influences brain circuits that control imitation. In the current fMRI study, we examined how the perception and belief of animacy influence the control of automatic imitation. Using an imitation-inhibition paradigm that involves suppressing the tendency to imitate an observed action, we manipulated both bottom-up (visual input) and top-down (belief) cues to animacy. Results show divergent patterns of behavioral and neural responses. Behavioral analyses show that automatic imitation is equivalent when one or both cues to animacy are present but reduces when both are absent. By contrast, right TPJ showed sensitivity to the presence of both animacy cues. Thus, we demonstrate that right TPJ is biologically tuned to control imitative tendencies when the observed agent both looks like and is believed to be human. The results suggest that right TPJ may be involved in a specialized capacity to control automatic imitation of human agents, rather than a universal process of conflict management, which would be more consistent with generalist theories of imitative control. Evidence for specialized neural circuitry that "controls" imitation offers new insight into developmental disorders that involve atypical processing of social information, such as autism spectrum disorders. PMID:24742157

  13. A computer-aided control system for automatic performance measurements on the LHC series dipoles

    International Nuclear Information System (INIS)

    The control system software (Test Master) for the Large Hadron Collider (LHC) magnet series measurements is presented. This system was developed at CERN to automate as many tests on the LHC magnets as possible. The Test Master software is the middle layer of the main software architecture developed by the LHC/IAS group for central supervision of all types of LHC dipole tests in the SM18 hall. It serves as a manager and scheduler for applications, controlling all measurements that are performed in a cluster of two test benches. The software was implemented in the LabVIEW environment. The information about the interactive user interface, the software architecture, communication protocols, file-configuration different types of commands and status files of the Test Master are described

  14. Automatic control strategy for step feed anoxic/aerobic biological nitrogen removal process

    Institute of Scientific and Technical Information of China (English)

    ZHU Gui-bing; PENG Yong-zhen; WU Shu-yun; WANG Shu-ying

    2005-01-01

    Control of sludge age and mixed liquid suspended solids concentration in the activated sludge process is critical for ensuring effective wastewater treatment. A nonlinear dynamic model for a step-feed activated sludge process was developed in this study. The system is based on the control of the sludge age and mixed liquor suspended solids in the aerator of last stage by adjusting the sludge recycle and wastage flow rates respectively. The simulation results showed that the sludge age remained nearly constant at a value of 16 d in the variation of the influent characteristics. The mixed liquor suspended solids in the aerator of last stage were also maintained to a desired value of 2500 g/m3 by adjusting wastage flow rates.

  15. Design of automatic control system for the precipitation of bromelain from the extract of pineapple wastes

    OpenAIRE

    Flavio Vasconcelos da Silva; Regina Lúcia de Andrade dos Santos; Tatiana Lie Fujiki; Manuela Souza Leite; Ana Maria Frattini Fileti

    2010-01-01

    In this work, bromelain was recovered from ground pineapple stem and rind by means of precipitation with alcohol at low temperature. Bromelain is the name of a group of powerful protein-digesting, or proteolytic, enzymes that are particularly useful for reducing muscle and tissue inflammation and as a digestive aid. Temperature control is crucial to avoid irreversible protein denaturation and consequently to improve the quality of the enzyme recovered. The process was carried out alternativel...

  16. ARM Based Automatic Control System of Nano Positioning Stage for Micromanufacturing

    Directory of Open Access Journals (Sweden)

    Gaurav Singh Naruka

    2013-05-01

    Full Text Available A microcontroller based control system to drive the Physik Instrumente (PI piezoelectric ultrasonic nano-positioning (PUN sta ge for a micro-factory has been proposed by the author. The tuning parameters of th e PI Line Controller are chosen such that the PUN stage shows optimum step response . The microcontroller i.e. LPC2478R provides the user with the choices of oper ations on the 3.2” QVGA LCD screen and the choice can be made by a 5-key joysti ck. The PUN stage moves in different geometrical patterns as chosen by the use r. The stage is placed in the workspace of the Clark-MXRR,Inc. CPA-2101 femto-sec ond laser. Different patterns are made on the material in question. As compared t o the previous works in this area, the user is given the power for position control, r eal time tracking, and trajectory planning of the actuator. The user interface has be en made very easy to comprehend. The repeatability of tasks, portability of the as- sembly, the reduction in the size of the system , power consumption and the human involvemen t are the major achievements after the inclusion of a microcontroller

  17. Design of automatic control system for the precipitation of bromelain from the extract of pineapple wastes

    Directory of Open Access Journals (Sweden)

    Flavio Vasconcelos da Silva

    2010-12-01

    Full Text Available In this work, bromelain was recovered from ground pineapple stem and rind by means of precipitation with alcohol at low temperature. Bromelain is the name of a group of powerful protein-digesting, or proteolytic, enzymes that are particularly useful for reducing muscle and tissue inflammation and as a digestive aid. Temperature control is crucial to avoid irreversible protein denaturation and consequently to improve the quality of the enzyme recovered. The process was carried out alternatively in two fed-batch pilot tanks: a glass tank and a stainless steel tank. Aliquots containing 100 mL of pineapple aqueous extract were fed into the tank. Inside the jacketed tank, the protein was exposed to unsteady operating conditions during the addition of the precipitating agent (ethanol 99.5% because the dilution ratio "aqueous extract to ethanol" and heat transfer area changed. The coolant flow rate was manipulated through a variable speed pump. Fine tuned conventional and adaptive PID controllers were on-line implemented using a fieldbus digital control system. The processing performance efficiency was enhanced and so was the quality (enzyme activity of the product.

  18. Predictors of Change Following Cognitive-Behavioral Treatment of Children with Anxiety Problems: A Preliminary Investigation on Negative Automatic Thoughts and Anxiety Control

    Science.gov (United States)

    Muris, Peter; Mayer, Birgit; den Adel, Madelon; Roos, Tamara; van Wamelen, Julie

    2009-01-01

    The purpose of the present study was to evaluate negative automatic thoughts and anxiety control as predictors of change produced by cognitive-behavioral treatment of youths with anxiety disorders. Forty-five high-anxious children aged between 9 and 12 years who were selected from the primary school population, received a standardized CBT…

  19. Air Pressurized Cabin Compressed Air Automatic Control System%空气加压氧舱压缩空气自动控制系统

    Institute of Scientific and Technical Information of China (English)

    郑志满; 张冕; 胡昕; 伍锡勇

    2011-01-01

    This paper describes a air pressurized cabin compressed air automatic control system, the designis simple, practical, safe and reliable.%本文介绍一种空气加压氧舱压缩空气自动控制系统,该设计简单、实用、安全、可靠.

  20. Waste gas radiation ignition control automatically%荒煤气自动放散点火控制

    Institute of Scientific and Technical Information of China (English)

    胡迪; 钦仿仿; 张天一

    2015-01-01

    介绍了西门子 S7—200PLC 在荒煤气自动放散点火控制系统中的应用,对其工作原理、过程、装置进行详细说明,通过 PLC 的控制对剩余煤气进行合理处理,保障管网压力的安全。本系统采用 Smart 作为编程工具,用 WinCC 软件组态相应的画面。%This paper introduces the Siemens S7 - 200 PLC in the automatic waste gas radiation ignition control system, the appli-cation of the detailed description of working principle, process, equipment, through the PLC control processing the residual gas in a reasonable manner, guarantee the safety of the pipeline pressure. This system adopts Smart as a programming tool, use WinCC software configuration of the corresponding picture.

  1. Flight test results for the Digital Integrated Automatic Landing Systems (DIALS): A modern control full-state feedback design

    Science.gov (United States)

    Hueschen, R. M.

    1984-01-01

    The Digital Integrated Automatic Landing System (DIALS) is discussed. The DIALS is a modern control theory design performing all the maneuver modes associated with current autoland systems: localizer capture and track, glideslope capture and track, decrab, and flare. The DIALS is an integrated full-state feedback system which was designed using direct-digital methods. The DIALS uses standard aircraft sensors and the digital Microwave Landing System (MLS) signals as measurements. It consists of separately designed longitudinal and lateral channels although some cross-coupling variables are fed between channels for improved state estimates and trajectory commands. The DIALS was implemented within the 16-bit fixed-point flight computers of the ATOPS research aircraft, a small twin jet commercial transport outfitted with a second research cockpit and a fly-by-wire system. The DIALS became the first modern control theory design to be successfully flight tested on a commercial-type aircraft. Flight tests were conducted in late 1981 using a wide coverage MLS on Runway 22 at Wallops Flight Center. All the modes were exercised including the capture and track of steep glidescopes up to 5 degrees.

  2. 矿用自动喷雾洒水控制器的设计%Design of Mine-used Automatic Spray and Watering Controller

    Institute of Scientific and Technical Information of China (English)

    于方洋

    2011-01-01

    The paper introduced design of a kind of automatic spray and watering controller. The controller uses main controller to control magnetic valve switch to achieve automatic watering of sprayer. The practical application showed that the controller has high reliability, good atomization effect, which average dust-laying rate is 92.7%.%介绍了一种自动喷雾洒水控制器的设计.该控制器利用控制主机控制电磁阀的开关,实现了喷雾装置的自动洒水.实际应用表明,该控制器可靠性高,雾化效果好,平均降尘率为92.7%.

  3. Potential of controlled traffic farming with automatic guidance on an organic farm in the Netherlands

    OpenAIRE

    Vermeulen, G.D.; Mosquera, J.; Wel, van der, GK; Klooster, van der, A.; Steenhuizen, J.W.

    2007-01-01

    Some organic farms in the Netherlands use RTK-DGPS guidance of machinery over fixed traffic lanes to achieve non-trafficked cropping zones with optimum soil structure. These lanes are not yet used for harvesting and primary tillage. The potential of such a seasonal controlled traffic farming (SCTF) system was evaluated. In an on-farm field experiment in green pea, spinach, onions and carrots, SCTF with traffic lanes at 3.15-m centres was compared with conventional random traffic farming (RTF)...

  4. New upper solution bounds for perturbed continuous algebraic Riccati equations applied to automatic control

    Energy Technology Data Exchange (ETDEWEB)

    Davies, Richard [School of Technology, University of Glamorgan, Pontypridd, CF37 1DL (United Kingdom)]. E-mail: rkdavies@glam.ac.uk; Peng Shi [School of Technology, University of Glamorgan, Pontypridd, CF37 1DL (United Kingdom)]. E-mail: pshi@glam.ac.uk; Wiltshire, Ron [School of Technology, University of Glamorgan, Pontypridd, CF37 1DL (United Kingdom)]. E-mail: rjwiltsh@glam.ac.uk

    2007-04-15

    In dynamical systems studies, the so-called Riccati and Lyapunov equations play an important role in stability analysis, optimal control and filtering design. In this paper, upper matrix bounds for the perturbation of the stabilizing solution of the continuous algebraic Riccati equation (CARE) are derived for the case when one, or all the coefficient matrices are subject to small perturbations. Comparing with existing works on this topic, the proposed bounds are less restrictive. In addition to these bounds, iterative algorithms are also derived to obtain more precise estimates.

  5. Digital systems for automatic control of optical resonators used as gravitational waves interferometric detectors

    Science.gov (United States)

    Barone, F.; Calloni, E.; de Rosa, R.; di Fiore, L.; Fusco, F.; Milano, L.; Russo, G.

    A feasibility study of a three-level digital control system developed under a joint Italian-French project, called Virgo, is presented. The Virgo antenna includes Fabry-Perot resonant cavity and a dual-wave Michelson interferometer with perpendicular arms 3 km each. The mirrors are seismically insulated through special suspensions and put in vacuum chambers connected by evacuated pipes. A state-of-the-art Nd:YAG laser with extremely low shot noise and high stability is used as a light source.

  6. An innovative exercise method to simulate orbital EVA work - Applications to PLSS automatic controls

    Science.gov (United States)

    Lantz, Renee; Vykukal, H.; Webbon, Bruce

    1987-01-01

    An exercise method has been proposed which may satisfy the current need for a laboratory simulation representative of muscular, cardiovascular, respiratory, and thermoregulatory responses to work during orbital extravehicular activity (EVA). The simulation incorporates arm crank ergometry with a unique body support mechanism that allows all body position stabilization forces to be reacted at the feet. By instituting this exercise method in laboratory experimentation, an advanced portable life support system (PLSS) thermoregulatory control system can be designed to more accurately reflect the specific work requirements of orbital EVA.

  7. Use of a beat effect for the automatic positioning of flow obstructions to control tonal fan noise: Theory and experiments

    Science.gov (United States)

    Gérard, A.; Berry, A.; Masson, P.; Moreau, S.

    2013-09-01

    Tonal noise generated by axial fans at the Blade Passage Frequency and its harmonics is a source of discomfort for low-speed fans used in many cooling and ventilation applications. The noise control approach presented here is based on the interference between the unsteady aerodynamic blade loads responsible for tonal noise generation and secondary aerodynamic loads generated in the rotor plane by fixed, carefully positioned, small obstructions in the upstream flow. Although not strictly active control, the magnitude and phase of the secondary tonal noise can be adjusted by varying the axial distance between the rotor and the obstruction, and the circumferential position of the obstruction, respectively. An optimal position of the obstruction generally exists, that minimizes the total noise at a given frequency. This paper establishes a practical method for automatic positioning of such control obstructions. In a first step, the method searches for the optimal axial distance between the rotor and the obstruction using a slowly rotating control obstruction. The modulation created by the rotation of the obstruction allows for the primary and secondary noises to be distinguished in the frequency response of the sound field. The steepest descent algorithm is used to find the optimal axial distance, for which the magnitudes of the primary and secondary tonal noise are equal at the error microphone. Then, the optimal angular position of the obstruction is obtained by slowly rotating the obstruction until minimal total noise is achieved. Finally, it is shown that at the optimal axial and angular position, the BPF tone, which produced the largest area in the loudness pattern, has been greatly reduced.

  8. An Automatic Quality Control Pipeline for High-Throughput Screening Hit Identification.

    Science.gov (United States)

    Zhai, Yufeng; Chen, Kaisheng; Zhong, Yang; Zhou, Bin; Ainscow, Edward; Wu, Ying-Ta; Zhou, Yingyao

    2016-09-01

    The correction or removal of signal errors in high-throughput screening (HTS) data is critical to the identification of high-quality lead candidates. Although a number of strategies have been previously developed to correct systematic errors and to remove screening artifacts, they are not universally effective and still require fair amount of human intervention. We introduce a fully automated quality control (QC) pipeline that can correct generic interplate systematic errors and remove intraplate random artifacts. The new pipeline was first applied to ~100 large-scale historical HTS assays; in silico analysis showed auto-QC led to a noticeably stronger structure-activity relationship. The method was further tested in several independent HTS runs, where QC results were sampled for experimental validation. Significantly increased hit confirmation rates were obtained after the QC steps, confirming that the proposed method was effective in enriching true-positive hits. An implementation of the algorithm is available to the screening community. PMID:27313114

  9. An Automatic Quality Control Pipeline for High-Throughput Screening Hit Identification.

    Science.gov (United States)

    Zhai, Yufeng; Chen, Kaisheng; Zhong, Yang; Zhou, Bin; Ainscow, Edward; Wu, Ying-Ta; Zhou, Yingyao

    2016-09-01

    The correction or removal of signal errors in high-throughput screening (HTS) data is critical to the identification of high-quality lead candidates. Although a number of strategies have been previously developed to correct systematic errors and to remove screening artifacts, they are not universally effective and still require fair amount of human intervention. We introduce a fully automated quality control (QC) pipeline that can correct generic interplate systematic errors and remove intraplate random artifacts. The new pipeline was first applied to ~100 large-scale historical HTS assays; in silico analysis showed auto-QC led to a noticeably stronger structure-activity relationship. The method was further tested in several independent HTS runs, where QC results were sampled for experimental validation. Significantly increased hit confirmation rates were obtained after the QC steps, confirming that the proposed method was effective in enriching true-positive hits. An implementation of the algorithm is available to the screening community.

  10. Fully automatic guidance and control for rotorcraft nap-of-the-Earth flight following planned profiles. Volume 1: Real-time piloted simulation

    Science.gov (United States)

    Clement, Warren F.; Gorder, Peter J.; Jewell, Wayne F.

    1991-01-01

    Developing a single-pilot, all-weather nap-of-the-earth (NOE) capability requires fully automatic NOE (ANOE) navigation and flight control. Innovative guidance and control concepts are investigated in a four-fold research effort that: (1) organizes the on-board computer-based storage and real-time updating of NOE terrain profiles and obstacles in course-oriented coordinates indexed to the mission flight plan; (2) defines a class of automatic anticipative pursuit guidance algorithms and necessary data preview requirements to follow the vertical, lateral, and longitudinal guidance commands dictated by the updated flight profiles; (3) automates a decision-making process for unexpected obstacle avoidance; and (4) provides several rapid response maneuvers. Acquired knowledge from the sensed environment is correlated with the forehand knowledge of the recorded environment (terrain, cultural features, threats, and targets), which is then used to determine an appropriate evasive maneuver if a nonconformity of the sensed and recorded environments is observed. This four-fold research effort was evaluated in both fixed-based and moving-based real-time piloted simulations, thereby, providing a practical demonstration for evaluating pilot acceptance of the automated concepts, supervisory override, manual operation, and re-engagement of the automatic system. Volume one describes the major components of the guidance and control laws as well as the results of the piloted simulations. Volume two describes the complete mathematical model of the fully automatic guidance system for rotorcraft NOE flight following planned flight profiles.

  11. DDF炉自动恒温控制系统设计与实现%Design and Implementation of Automatic Constant Temperature Control System for DDF Furnace

    Institute of Scientific and Technical Information of China (English)

    蔡红梅

    2015-01-01

    通过设计回转窑熟料烧成系统分解炉(DDF炉)自动恒温控制系统,提高系统的稳定性和可靠性.传统的DDF炉自动恒温控制系统的数据采集及温度控制单元采用有源晶振A/D时钟采样控制方法,导致基线漂移,恒温控制性能不好.提出一种基线漂移交流耦合控制的DDF炉自动恒温控制系统设计方法.在炉内温度离散采集的基础上,进行温度控制曲线拟合,设计基线漂移交流耦合控制的DDF炉自动恒温控制算法,实现对DFF炉温度控制的优化预测,进行硬件电路设计,实现对自动恒温控制系统设计和改进.仿真结果表明,该系统能有效避免恒温控制中的基线漂移,温度跟踪性能较好,具有较好的稳定输出,能有效应用在DDF炉恒温控制中.%The automatic constant temperature control system of the clinker burning system of rotary kiln (DDF) is designed, and the stability and reliability of the system are improved.. Traditional DDF furnace automatic constant temperature con-trol system of the data acquisition system and the temperature control unit using active crystal A/D sampling clock control method, resulting in the baseline drift and constant temperature control performance is not good. A design method of auto-matic constant temperature control system for DDF furnace is presented, which is controlled by the exchange and coupling of the baseline drift. In furnace based on discrete temperature acquisition, temperature control curve fitting and control de-sign baseline drift AC coupled DDF furnace automatic constant temperature control algorithm to achieve on DFF furnace temperature control optimization prediction, hardware circuit design and Realization of automatic constant temperature con-trol system design and improvement. The simulation results show that the system can effectively avoid the baseline drift in the constant temperature control, the temperature tracking performance is good, and has good stable output

  12. Automatic system for blood donors control with seropositive results in epidemiological tests.

    Directory of Open Access Journals (Sweden)

    Ariel Menéndez Barrios

    2008-04-01

    Full Text Available Background: Prevention of infectious diseases transmission through blood transfusion is one of the biggest challenges in the transfusion field of medicine. Objective: to design a computerized system for blood donors control with seropositive results in epidemiological tests. Methods: A system designed by the Provincial Blood Bank using Microsoft Access as a data base system and DELFHI 7 as associated language. It runs under Windows 2000 or any other superior system with 64 RAM and do not need special requirements of software or hardware. It includes the following data: Full name, age, sex, race, Id number, home address, number of the clinical record in the blood bank, date when the trial took place in each patient, kind of disease diagnosed, technical data of the trial such as: fluorescence, sectional level of the 1st trial as well as the repetition, name of the technician who performed it. Results: It permits to consult general data of donors as well as the disease diagnosed. It also permits to elaborate reports of these patients from any PC of the blood bank acceding with the security password of the program. Conclusions: It constitutes a beneficial tool which permits to improve the notification system established in the program of the web about sexually transmitted diseases from the Minister of Public Health in Cuba.

  13. Fuzzy Controller for Automatic Steering in Heavy Vehicle Semi-Trailers

    Directory of Open Access Journals (Sweden)

    Herrera-Ruíz G.

    2013-01-01

    Full Text Available Los camiones con semi-remolques son ampliamente utilizados para el transporte de mercancías debido a su bajo costo de operación, sino inherentes a estos vehículos son algunos problemas como una mala maniobrabilidad. Para minimizar los efectos de esta desventaja, entre otras soluciones, la incorporación de ejes orientables en los semirremolques se ha propuesto. Este artículo presenta una ecuación de dirección, y un controlador de lógica difusa para un semi-remolque automático forzado sistema de dirección para reducir al mínimo el apagado de seguimiento y la anchura total en curva, lo que resulta en una mejora de la maniobrabilidad del vehículo a baja velocidad. Para lograr esto, el algoritmo de control propuesto considera el ángulo de articulación y parámetros tales como la velocidad y dirección del vehículo. El sistema se probó en un instrumentada experimental semi-remolque durante varias maniobras de prueba predeterminados.

  14. Design of Wireless Sensor Network-Based Greenhouse Environment Monitoring and Automatic Control System

    Directory of Open Access Journals (Sweden)

    Yongxian Song

    2012-05-01

    Full Text Available  In view of the characteristics of greenhouse environment monitoring system, a system scheme based on wireless sensor network (WSN is presented, which adopts Atmega128L chip and CC2530 that is a low power RF chip from TI to design the sink node and sensor nodes in the WSN. The monitoring and management center can control the temperature and humidity of the greenhouse, measure the carbon dioxide content, and collect the information about intensity of illumination, and so on. And the system adopts multilevel energy memory. It combines energy management with energy transfer, which makes the energy collected by solar energy batteries be used reasonably. Therefore, the self-managing energy supply system is established. In addition, the nodes deployment method and time synchronization problem are analyzed in detail. The system can solve the problem of complex cabling with the advantages of low power consumption, low cost, good robustness, extended flexible and high reliability. An effective tool is provided for monitoring and analysis decision-making of the greenhouse environment.

  15. Characteristics of «Gas-Burning Device - Technological Zone» System as Object of Automatic Control and Equation of General Heat Duty of Heating (Heat-Treating) Furnace

    OpenAIRE

    A. P. Nesenchuk; N. L. Mandel; T. V. Ryzhova; M. G. Pshonik; D. I. Shklоvchik; Z. B. Аidarоva

    2014-01-01

    An equation pertaining to dynamics of automatic control of «gas-burning device - high-temperature zone» object has been formulated in the paper. The equation may serve as a basis for development of automatic control scheme. 

  16. Hybrid evolutionary algorithm based fuzzy logic controller for automatic generation control of power systems with governor dead band non-linearity

    Directory of Open Access Journals (Sweden)

    Omveer Singh

    2016-12-01

    Full Text Available A new intelligent Automatic Generation Control (AGC scheme based on Evolutionary Algorithms (EAs and Fuzzy Logic concept is developed for a multi-area power system. EAs i.e. Genetic Algorithm–Simulated Annealing (GA–SA are used to optimize the gains of Fuzzy Logic Algorithm (FLA-based AGC regulators for interconnected power systems. The multi-area power system model has three different types of plants i.e. reheat, non-reheat and hydro and are interconnected via Extra High Voltage Alternate Current transmission links. The dynamic model of the system is developed considering one of the most important Governor Dead Band (GDB non-linearity. The designed AGC regulators are implemented in the wake of 1% load perturbation in one of the control areas and the dynamic response plots are obtained for various system states. The investigations carried out in the study reveal that the system dynamic performance with hybrid GA–SA-tuned Fuzzy technique (GASATF-based AGC controller is appreciably superior as compared to that of integral and FLA-based AGC controllers. It is also observed that the incorporation of GDB non-linearity in the system dynamic model has resulted in degraded system dynamic performance.

  17. 基于PLC控制的包装码垛生产钱的设计%Design of automatic bagging and palletizing line based on PLC control system

    Institute of Scientific and Technical Information of China (English)

    王平; 黄玉志

    2011-01-01

    我国的聚丙烯(即)产量占世界产量的10%以上,而长期以来国内聚丙烯产品的包装却一直处于人工套袋的半自动包装状态.针对即树脂的特点,专门设计了全自动包装码跺生产线工艺流程,介绍了以PLC为基础的全自动包装码哚生产线控制系统,重点说明了控制系统的硬件配置、输入输出分配和软件设计.全自动包装码垛线改变了国内PP产品包装的落后局面,位得在PP包装领城推广.%The production of PP in china accounts for more than 10% of world plodunction, while the packing of domestic pp products has been in a semi-automatic condition for a long time, Charactersistics for PP resin, the technologic process of automatic hagging and palletizing line was introduced. A set of automatic bagging and palletizing line control system based on PLC was designed. Emphasis the hardware disposition of control system, I/O allotment and software system. Automatic bagging and palletizing line changed the back ward PP packaging in domestic, worthy to promotion.

  18. Automaticity or active control

    DEFF Research Database (Denmark)

    Tudoran, Ana Alina; Olsen, Svein Ottar

    This study addresses the quasi-moderating role of habit strength in explaining action loyalty. A model of loyalty behaviour is proposed that extends the traditional satisfaction–intention–action loyalty network. Habit strength is conceptualised as a cognitive construct to refer to the psychologic...

  19. 汽车电控自动变速技术及发展趋势%Electronically Controlled Automatic Transmission Car Technology and its Development Trend

    Institute of Scientific and Technical Information of China (English)

    宋燕

    2009-01-01

    The electronically controlled automatic transmission to achieve the best shift, with good economic and sexual power, low-pollution; stable and reliable work, well adapted to complex traffic conditions and geographical conditions; no impact on the process of shifting and vibration, the shift action accurate, timely and easily manipulated; and has a fault self-diagnosis function. In this paper, electronically controlled automatic transmission type, the basic principles of composition and control, electronically controlled automatic transmission technology trends.%电子控制自动变速器能实现最佳的换档规律,具有良好的经济性和动力性,污染低;工作稳定可靠,能很好地适应复杂的交通情况和地理条件;换档过程无冲击和振动,换档动作准确、及时,操纵方便;且具有故障自诊断功能.介绍电控自动变速器的类型、基本组成和控制原理及电控自动变速技术的发展趋势.

  20. Automatic chemical monitoring in the composition of functions performed by the unit level control system in the new projects of nuclear power plant units

    Science.gov (United States)

    Denisova, L. G.; Khrennikov, N. N.

    2014-08-01

    The article presents information on the state of regulatory framework and development of a subsystem for automated chemical monitoring of water chemistries in the primary and secondary coolant circuits used as part of the automatic process control system in new projects of VVER reactor-based nuclear power plant units. For the strategy of developing and putting in use the water chemistry-related part of the automated process control system within the standard AES-2006 nuclear power plant project to be implemented, it is necessary to develop regulatory documents dealing with certain requirements imposed on automatic water chemistry monitoring systems in accordance with the requirements of federal codes and regulations in the field of using atomic energy.

  1. Analysis of results obtained using the automatic chemical control of the quality of the water heat carrier in the drum boiler of the Ivanovo CHP-3 power plant

    Science.gov (United States)

    Larin, A. B.; Kolegov, A. V.

    2012-10-01

    Results of industrial tests of the new method used for the automatic chemical control of the quality of boiler water of the drum-type power boiler ( P d = 13.8 MPa) are described. The possibility of using an H-cationite column for measuring the electric conductivity of an H-cationized sample of boiler water over a long period of time is shown.

  2. Engineering model of the electric drives of separation device for simulation of automatic control systems of reactive power compensation by means of serially connected capacitors

    Science.gov (United States)

    Juromskiy, V. M.

    2016-09-01

    It is developed a mathematical model for an electric drive of high-speed separation device in terms of the modeling dynamic systems Simulink, MATLAB. The model is focused on the study of the automatic control systems of the power factor (Cosφ) of an actuator by compensating the reactive component of the total power by switching a capacitor bank in series with the actuator. The model is based on the methodology of the structural modeling of dynamic processes.

  3. NERI Project 99-119. A New Paradigm for Automatic Development of Highly Reliable Control Architectures for Nuclear Power Plants. Phase-2 Progress Report

    Energy Technology Data Exchange (ETDEWEB)

    March-Leuba, JA

    2002-01-15

    This report describes the tasks performed and the progress made during Phase 2 of the DOE-NERI project number 99-119 entitled Automatic Development of Highly Reliable Control Architecture for Future Nuclear Power Plants. This project is a collaboration effort between the Oak Ridge National Laboratory (ORNL), The University of Tennessee, Knoxville (UTK) and the North Carolina State University (NCSU). ORNL is the lead organization and is responsible for the coordination and integration of all work.

  4. The evaluation of the performance of the automatic exposure control system of some selected mammography facilities in the Greater Accra Region, Ghana

    International Nuclear Information System (INIS)

    Mammography aids in the early detection of breast cancer. X-rays has an associated risk of inducing cancer though very useful and as such mammography procedures should be optimized through the appropriate processes such as the selection of exposure factors for an optimum image and minimal dose to patients. The automatic exposure control (AEC) aids in the selection of exposure factors thus controlling the amount of radiation to the breast and automatically compensates for differences in the breast thickness and density. The performance of the automatic exposure control system of mammography equipment and the status of quality management systems including quality assurance and quality controls of four (4) mammography facilities within the Greater Accra Region were assessed. In assessing the performance of the automatic exposure control system, the short term reproducibility test, thickness and voltage compensation test were carried out using breast equivalent phantom of various thicknesses. Half value layer test, film reject analysis and patient dose assessment were also performed. Analysis of the responses of the questionnaire administered to radiographers and supervisors of the selected facilities revealed that three (3) of the facilities have some aspect of quality management system programme in place but not effectively implemented. Measured optical densities from the various tests performed to evaluate the performance of the automatic exposure control systems revealed that the AEC compensates for the different phantom thickness and tube voltage (KV) by producing comparable optical densities for the various phantom thickness and tube voltages. Some of the measured optical densities were within the recommended optical density range of 1.5 OD - 1.9 OD. The highest optical density value was 0.13 OD above the highest limit of 1.9 OD. The film reject analysis showed that patient motion accounted for the large part (28%) of film rejects. Other factors such as too light

  5. Solar Automatic Tracking Double Fuzzy Control System Based on ARM%基于ARM的太阳自动跟踪双模糊控制系统

    Institute of Scientific and Technical Information of China (English)

    刘景艳; 李玉东; 杨晓邦

    2012-01-01

    针对太阳自动跟踪系统采用常规的PID控制器存在着跟踪精度低,超调量大等缺点,提出了一种基于ARM的太阳自动跟踪双模糊控制系统的设计方案;以32位ARM嵌入式微处理器为核心,采用光电跟踪和太阳运动轨迹跟踪相结合的混合跟踪模式;在光电跟踪模式下.采用模糊控制;在太阳运动轨迹跟踪模式下,采用模糊PID分段式控制,并依据光强的大小自动切换控制器;采用两个同样规格的太阳能电池板,分别采用固定安装和太阳自动跟踪系统测试太阳能电池板的采光强度;实验结果表明,该系统具有较高的跟踪精度,实现了对太阳全天候的跟踪,有效地提高了光电转换效率.%The solar automatic tracking system adopting the conventional PID controller has low tracking precision and big overshoot. The solar automatic tracking double fuzzy control system based on ARM is put forward. Embedded microcontroller 32-bit ARM processor is the core. A kind of mixed tracking mode is adopted, and it combines photoelectric tracking mode and solar trajectory tracking mode. The double fuzzy control method is presented, the fuzzy control method is adopted in photoelectric tracking mode, and in solar trajectory tracking mode, the fuzzy PID segmented tracking control method is put forward. And the controller can be automatically switched control mode according to light intensity. The fixed installation and the automatic tracking system are respectively used to test the solar panels daylighting strength. The experimental results show that the solar automatic tracking system is possessed of high tracking precision, realizes the sun round-the-clock tracking and effectively improves the photoelectric conversion efficiency.

  6. 基于PLC的自动送铆控制系统设计%The Design of Control System for Automatic Feeding Rivet Machine

    Institute of Scientific and Technical Information of China (English)

    刘寰; 罗英; 秦现生; 沈东莹; 刘勇

    2011-01-01

    The paper introduces the control system about the automatic feeding rivet machine, which is composed of PLC, Human-machine interface and detecting element. It describes in detail the basic control function, the structure of the hardware and the design of Control Software.%介绍了采用可编程控制器( S7-200 PLC)、触摸屏和检测元件构成的自动钻铆设备的控制系统,阐述了控制系统的控制功能、硬件设计和软件设计.

  7. Application of Automatic Shift Control Technique in Tractor%自动换档控制技术在拖拉机上的应用

    Institute of Scientific and Technical Information of China (English)

    郭星野

    2011-01-01

    when the control technology of automatic transmission is adopted on the tractor, the driver can be liberated from strenuous operation.This article analyzes the shifting process of automatic gear-box, based on systematic dynamics model of vehicle,and proposes that change gear time is taken for the control goal ,that the automatic shift control technology is applied to the tractor.%在拖拉机上应用自动换档控制技术,可使驾驶员从繁重的换档操作中解放出来.通过对电控机械式自动变速箱换档过程的分析,以车辆系统动力学模型为基础,提出了以换档时间为控制目标,在拖拉机上应用自动换档控制技术的工程实施方案.

  8. Automatic Web-Based, Radio-Network System To Monitor And Control Equipment For Investigating Gas Flux At Water - Air Interfaces

    Science.gov (United States)

    Duc, N. T.; Silverstein, S.; Wik, M.; Beckman, P.; Crill, P. M.; Bastviken, D.; Varner, R. K.

    2015-12-01

    Aquatic ecosystems are major sources of greenhouse gases (GHG). Robust measurements of natural GHG emissions are vital for evaluating regional to global carbon budgets and for assessing climate feedbacks on natural emissions to improve climate models. Diffusive and ebullitive (bubble) transport are two major pathways of gas release from surface waters. To capture the high temporal variability of these fluxes in a well-defined footprint, we designed and built an inexpensive automatic device that includes an easily mobile diffusive flux chamber and a bubble counter, all in one. Besides a function of automatically collecting gas samples for subsequent various analyses in the laboratory, this device utilizes low cost CO2 sensor (SenseAir, Sweden) and CH4 sensor (Figaro, Japan) to measure GHG fluxes. To measure the spatial variability of emissions, each of the devices is equipped with an XBee module to enable a local radio communication DigiMesh network for time synchronization and data readout at a server-controller station on the lakeshore. Software of this server-controller is operated on a low cost Raspberry Pi computer which has a 3G connection for remote monitoring - controlling functions from anywhere in the world. From field studies in Abisko, Sweden in summer 2014 and 2015, the system has resulted in measurements of GHG fluxes comparable to manual methods. In addition, the deployments have shown the advantage of a low cost automatic network system to study GHG fluxes on lakes in remote locations.

  9. Predicting automaticity in exercise behaviour: the role of perceived behavioural control, affect, intention, action planning, and behaviour

    NARCIS (Netherlands)

    G.J. de Bruijn; B. Gardner; L. van Osch; F.F. Sniehotta

    2014-01-01

    Background Habit formation has been proposed as a way to maintain behaviour over time. Purpose Recent evidence suggests that constructs additional to repeated performance may predict physical automaticity, but no research has yet explored possible direct impacts of intention, planning, affect, and p

  10. Wean Earlier and Automatically with New technology (the WEAN study: a protocol of a multicentre, pilot randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Lessard Martin R

    2009-09-01

    Full Text Available Abstract Background Weaning is the process during which mechanical ventilation is withdrawn and the work of breathing is transferred from the ventilator back to the patient. Prolonged weaning is associated with development of ventilator-related complications and longer stays in the Intensive Care Unit (ICU. Computerized or Automated Weaning is a novel weaning strategy that continuously measures and adapts ventilator support (by frequently measuring and averaging three breathing parameters and automatically conducts Spontaneous Breathing Trials to ascertain whether patients can resume autonomous breathing. Automated Weaning holds promise as a strategy to reduce the time spent on the ventilator, decrease ICU length of stay, and improve clinically important outcomes. Methods/Design A pilot weaning randomized controlled trial (RCT is underway in the ICUs of 8 Canadian hospitals. We will randomize 90 critically ill adults requiring invasive ventilation for at least 24 hours and identified at an early stage of the weaning process to either Automated Weaning (SmartCare™ or Protocolized Weaning. The results of a National Weaning Survey informed the design of the Protocolized Weaning arm. Both weaning protocols are operationalized in Pressure Support mode, include opportunities for Spontaneous Breathing Trials, and share a common sedation protocol, oxygen titration parameters, and extubation and reintubation criteria. The primary outcome of the WEAN study is to evaluate compliance with the proposed weaning and sedation protocols. A key secondary outcome of the pilot RCT is to evaluate clinician acceptance of the weaning and sedation protocols. Prior to initiating the WEAN Study, we conducted a run-in phase, involving two patients per centre (randomizing the first participant to either weaning strategy and assigning the second patient to the alternate strategy to ensure that participating centres could implement the weaning and sedation protocols and

  11. 给水调节阀自动控制效果的优化%Optimization of the Automatic Control Effect of Feedwater Regulating Valve

    Institute of Scientific and Technical Information of China (English)

    俞利锋

    2012-01-01

    In order to optimize the automatic control effect of the boiler feedwater regulating valve, some factors affecting the control effect of feedwater regulating valve are analyzed and researched, such as the accuracy of parameters measurement, dynamic characteristic of drum water level, basic control principle, and the rationality of parameters processing and equipment selection. The factors affecting the automatic control are optimized, such as parameters compensation and correction, control strategy optimization, parameters reasonable filtering and equipment rational selection. Practice shows that automatic control effect is improved and equipment life is extended by conducting a series of optimization processes.%为优化锅炉给水调节阀自动控制的效果,对影响给水调节阀控制效果的参数测量的精确性、汽包水位的动态特性、基本的控制原理、参数处理和设备选用的合理性进行了分析研究.对参数的补偿修正、控制策略的优化、参数的合理滤波以及设备的合理选型等影响自动控制效果的因素进行了优化处理.实践表明,通过一系列的优化处理既能优化自动控制的效果,又能延长设备使用寿命.

  12. 螺纹塑料注射模的机电一体化控制%Electromechanical Integration Automatic Control of Rotary Mold

    Institute of Scientific and Technical Information of China (English)

    于治策; 桑玉红

    2011-01-01

    The traditional automatic demoulding thread mold was improved, using electrical components control motor movement, through the chain transmission drive screw thread core to rotate, the smooth realization of thread automatic demoulding products. Achieve mechanical and electrical integration of technology in the mold, it has great promotional value.%对传统的自动脱螺纹模具进行改进,利用电气元件控制电动机动作,通过链传动带动螺纹型芯转动,顺利实现螺纹制品的自动脱模。机电一体化技术在模具中的实现,有很大的推广价值。

  13. The research and development of electronic controlled mechanical automatic transmission%关于电控机械式自动变速器的研发分析

    Institute of Scientific and Technical Information of China (English)

    刘小红

    2016-01-01

    In this paper,a selection of automatic mechanical transmission(AMT)structure,design points,the working principle as a starting point,research and development of electronically controlled mechanical automatic transmission device,through the study of this subject,contribute to the development of automated mechanical transmission (AMT).%本文则是选取电控机械式自动变速器的结构、设计要点、工作原理作为切入点,研究开发电控机械式自动变速器,通过这一课题的研究,有助于开发电控机械式自动变速器。

  14. Re-emerging conceptual integration: commentary on Berkowitz's "on the consideration of automatic as well as controlled psychological processes in aggression".

    Science.gov (United States)

    Pahlavan, Farzaneh

    2008-01-01

    In recent decades, researchers in various areas of psychology have challenged the claims of a single mode of information processing, and developed dual-process models of social behaviors. Although these theories differ on a number of dimensions, they all share the basic assumption that two different modes of information processing operate in making decision and copying behavior. In essence, the common distinction in these perspectives is between controlled vs. automatic, conscious vs. unconscious, and affective vs. cognitive modes of processing. The purpose of Berkowitz's article is to go beyond the notion of automatic processes in order to use classic notions of conditioning and displacement to explain aggressive behavior. I assert that an explanatory framework for psychology of aggression must be anchored not only in the new but also classic theoretical paradigms. However, progress in psychology does not rest solely on the accumulation of theoretical insights. It demands a large body of empirical facts, with attention to incongruities, discordances, and conceptual clarifications.

  15. A program for assisting automatic generation control of the ELETRONORTE using artificial neural network; Um programa para assistencia ao controle automatico de geracao da Eletronorte usando rede neuronal artificial

    Energy Technology Data Exchange (ETDEWEB)

    Brito Filho, Pedro Rodrigues de; Nascimento Garcez, Jurandyr do [Para Univ., Belem, PA (Brazil). Centro Tecnologico; Charone Junior, Wady [Centrais Eletricas do Nordeste do Brasil S.A. (ELETRONORTE), Belem, PA (Brazil)

    1994-12-31

    This work presents an application of artificial neural network as a support to decision making in the automatic generation control (AGC) of the ELETRONORTE. It uses a software to auxiliary in the decisions in real time of the AGC. (author) 2 refs., 6 figs., 1 tab.

  16. The speed of magnitude processing and executive functions in controlled and automatic number comparison in children: an electro-encephalography study

    Directory of Open Access Journals (Sweden)

    Jármi Éva

    2007-04-01

    Full Text Available Abstract Background In the numerical Stroop paradigm (NSP participants decide whether a digit is numerically or physically larger than another simultaneously presented digit. This paradigm is frequently used to assess the automatic number processing abilities of children. Currently it is unclear whether an equally refined evaluation of numerical magnitude occurs in both controlled (the numerical comparison task of the NSP and automatic (the physical comparison task of the NSP numerical comparison in both children and adults. One of our objectives was to respond this question by measuring the speed of controlled and automatic magnitude processing in children and adults in the NSP. Another objective was to determine how the immature executive functions of children affect their cognitive functions relative to adults in numerical comparison. Methods and results The speed of numerical comparison was determined by monitoring the electro-encephalographic (EEG numerical distance effect: The amplitude of EEG measures is modulated as a function of numerical distance between the to-be-compared digits. EEG numerical distance effects occurred between 140–320 ms after stimulus presentation in both controlled and automatic numerical comparison in all age groups. Executive functions were assessed by analyzing facilitation and interference effects on the latency of the P3b event-related potential component and the lateralized readiness potential (LRP. Interference effects were more related to response than to stimulus processing in children as compared with adults. The LRP revealed that the difficulty to inhibit irrelevant response tendencies was a major factor behind interference in the numerical task in children. Conclusion The timing of the EEG distance effect suggests that a refined evaluation of numerical magnitude happened at a similar speed in each age group during both controlled and automatic magnitude processing. The larger response interference in

  17. Automatic Reading

    Institute of Scientific and Technical Information of China (English)

    胡迪

    2007-01-01

    <正>Reading is the key to school success and,like any skill,it takes practice.A child learns to walk by practising until he no longer has to think about how to put one foot in front of the other.The great athlete practises until he can play quickly,accurately and without thinking.Ed- ucators call it automaticity.

  18. Development of a Motor Driven Rowing Machine with Automatic Functional Electrical Stimulation Controller for Individuals with Paraplegia; a Preliminary Study

    OpenAIRE

    Jung, Da-Woon; Park, Dae-Sung; Lee, Bum-Suk; Kim, Min

    2012-01-01

    Objective To examine the cardiorespiratory responses of patients with spinal cord injury (SCI) paraplegia using a motor driven rowing machine. Method Ten SCI patients with paraplegia [A (n=6), B (n=1), and C (n=3) by the American Spinal Injury Association impairment scale] were selected. Two rowing techniques were used. The first used a fixed seat with rowing achieved using only upper extremity movement (fixed rowing). The second used an automatically moving seat, facilitating active upper ex...

  19. 自动控制原理网络考试系统设计%The Design on Online Test System on Automatic Control Principle

    Institute of Scientific and Technical Information of China (English)

    孟宁; 李涛

    2014-01-01

    该自动控制原理考试系统由管理员管理模块、考生在线考试模块两部分组成。系统基于B/S结构,采用ASP技术、ACCESS数据库等技术,实现了从题库自动组题、在线测试、自动判卷、成绩查询、考生管理、试题管理等功能。其特点是实现了考生身份认证、批量更新题库、显示曲线图如Bode图等功能。%This Design on Online Test System on Automatic Control Principle is composed of two parts named as administrator management module and students online test module. It is based on B/S structure using ASP technology, ACCESS database tech-nology to create the examinations from question bank automatically, online testing, automatic marking questions, query results, student management, and test management. Its characteristic is to realize Candidates authentication, batch update questions of the tests,display graph such as Bode plot.

  20. PLC在天线自动交换控制系统中的应用%Application of PLC in Automatic Antenna Switching Control System

    Institute of Scientific and Technical Information of China (English)

    巫建江

    2016-01-01

    本文简要介绍可编程控制器PLC工作原理,以及PLC在天线自动控制系统运用的可行性和可靠性。针对我台乙机房发射机原互代时因需要人工倒换操作,存在既不安全、又不准确等问题进行了分析;论述了应用PLC技术,对天线交换控制开关进行自动控制改造,使本机房各发射机之间,机房与机房之间的发射机和发射天线实现了互联、互通、互代。%This article briefly describes the working principle of PLC programmable logic controller, and PLC in automatic control system uses an antenna feasibility and reliability. B room for my station transmitter when the original cross-generation due to the need for manual switching operation, there are neither safe nor accurate problem analysis;discusses the application of PLC technology, the antenna switching control switch for automatic control transformation, so that the engine room between the transmitter, the transmitter and transmitting antenna between the engine room and the room to achieve the interconnection, interoperability, mutual generations.

  1. Improvement The Transmission Efficiency For Wireless Packet Communication Systems Using Automatic Control for power And Time Slot Width Of Slotted Non persistent ISMA Protocol

    Directory of Open Access Journals (Sweden)

    Saad M. Hardan

    2013-05-01

    Full Text Available In packed communication systems which use a protocol, the protocol should perform the allocation of channels such that the transmission channel is used efficiently. Efficiency is usually measured in terms of channel throughput and the average transmission  delay. The Slotted Nonpersistent ISMA protocol is one of random access protocols used in packed communication systems. In this research a Slotted Nonpersistent ISMA protocol Model with automatic control for power and time slot is proposed. the suggested algorithm enable the base station(access point to control  the protocol time slot length and  transmission power in a dynamic way to control the normalized propagation delay d and to maintain all the uplink signals in the limit of captured power threshold (capture ratio in order to control the  throughput and the average transmission delay of the communication system by an automatic method. the computer simulation results  confirm the activity of the  proposed algorithm for increasing the  throughput and decreasing the average transmission delay by an accepted ratios.

  2. Loop gain stabilizing with an all-digital automatic-gain-control method for high-precision fiber-optic gyroscope.

    Science.gov (United States)

    Zheng, Yue; Zhang, Chunxi; Li, Lijing; Song, Lailiang; Chen, Wen

    2016-06-10

    For a fiber-optic gyroscope (FOG) using electronic dithers to suppress the dead zone, without a fixed loop gain, the deterministic compensation for the dither signals in the control loop of the FOG cannot remain accurate, resulting in the dither residuals in the FOG rotation rate output and the navigation errors in the inertial navigation system. An all-digital automatic-gain-control method for stabilizing the loop gain of the FOG is proposed. By using a perturbation square wave to measure the loop gain of the FOG and adding an automatic gain control loop in the conventional control loop of the FOG, we successfully obtain the actual loop gain and make the loop gain converge to the reference value. The experimental results show that in the case of 20% variation in the loop gain, the dither residuals are successfully eliminated and the standard deviation of the FOG sampling outputs is decreased from 2.00  deg/h to 0.62  deg/h (sampling period 2.5 ms, 10 points smoothing). With this method, the loop gain of the FOG can be stabilized over the operation temperature range and in the long-time application, which provides a solid foundation for the engineering applications of the high-precision FOG. PMID:27409016

  3. Automatic system of tests for control equipment in combined cycle power stations; Sistema automatico de pruebas para equipos de control en centrales de ciclo combinado

    Energy Technology Data Exchange (ETDEWEB)

    Martinez M, Miguel A; Flores L, Zenon; Delgadillo V, Miguel A; Gutierrez A, Ruben [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2001-07-01

    This article deals on the Automatic System of Tests, denominated PROBADOR, used by the Gerencia de Control e Instrumentation (GCI) of the Instituto de Investigaciones Electricas (IIE)for the accomplishment of dynamic tests in laboratory, to the systems of acquisition and control developed with the electronic line SAC-IIE that are installed in the Thermoelectric Power station of Combined Cycle (CTCC) of Dos Bocas, Veracruz and Gomez Palacio, Durango, Mexico. Also the architecture, the functions that are carried out in the equipment of the System of Acquisition and control (SAC) and in the personal computer (PC) that conforms it are described, as well as the methodology used for the development of the tests. The PC constitutes Interface Man-Machine (IMM) and in the SAC equipment the simulation of the processes is made (by means of the execution of algebraic-differential equations) in the compressor, combustion chamber, gas turbine, heat recuperators, steam turbines and condenser equipment that integrate a CTCC. The equations that are used are based in the thermodynamics, flow dynamics and heat transfer; they become attached to the real process with a margin of error that is estimated in 10%. Finally, the tendencies of the PROBADOR and the technical and economic advantages are described that it has provided for the improvement in the performance of the control systems, before different situations, with no need to have the real process. [Spanish] Este articulo versa sobre el Sistema Automatico de Pruebas, denominado PROBADOR, utilizado por la Gerencia de Control e Instrumentacion (GCI) del Instituto de Investigaciones Electricas para la realizacion de pruebas dinamicas en laboratorio, a los sistemas de adquisicion y control desarrollado con la linea electronica SAC-IIE que estan instalados en las Centrales Termoelectricas de Ciclo Combinado (CTCC) de Dos Bocas, Veracruz y Gomez Palacio, Durango, Mexico. Tambien se describen la arquitectura, las funciones que se llevan

  4. 自动闭环机械通气控制器的设计%Design of a closed-loop automatic mechanical ventilation controller

    Institute of Scientific and Technical Information of China (English)

    端慧敏; 陈爱华; 詹宁波

    2014-01-01

    Objective:In the clinical mechanical ventilation practice, the medical workers often set the ventilator parameters only depend on their own experience. In order to change that,we design a Closed-Loop Automatic Mechanical Ventilation Controller.Methods: Design two closed-loop control subsystems to meet the requirements of closed-loop control system. PETCO2 control subsystem used to keep the concentration of PETCO2, and another subsystem design to regulate the respiratory elasticity called PEEP control subsystem. PETCO2 control subsystem can work on its own or work with PEEP control subsystem.Results: Using this closed-loop controller, the partial CO2 pressure and respiratory elasticity of patient was regulated in real time.Conclusion:By using this closed-loop automatic mechanical ventilation controller, the respiratory elasticity was largely reduced with the adequate gas exchange. Therefore, the ventilator using this closed-loop automatic mechanical ventilation controller can improve the ventilation quality and also reduce the risk of lung injury.%目的:设计一种自动闭环机械通气控制器,为改变临床机械通气治疗过程中,通气参数依靠医生个人经验判断进行设定的现状。方法:针对闭环控制系统要求,设计两个闭环控制子系统:维持呼气末二氧化碳(PETCO2)浓度的PETCO2控制系统和调节呼吸弹性的呼气末正压(PEEP)控制系统。PETCO2控制系统既可以独立工作也能够与PEEP控制系统联合工作。结果:实现了患者PETCO2和呼吸弹性水平的闭环自动控制。结论:自动闭环机械通气控制器可在维持必要通气的基础上,降低呼吸弹性,提高了临床呼吸治疗效果和质量。

  5. 缝纫线绕线机自动控制系统的设计%Design of automatic control system of sewing thread winding machine

    Institute of Scientific and Technical Information of China (English)

    柯良; 冯关明; 章建军; 陈水明

    2014-01-01

    According to the problems such as the low lever of automation and high requirement of operators,designed a kind of au-tomatic control system of sewing thread winding machine based on Sequential Function Chart ( SFC) .On the basis of structure of the sewing thread winding machine,analyzed the principle and work process of the machine,taken advantage of logical of sequen-tial function chart,accomplished the design and program of automatic control system,developed a kind of automatic control system of sewing thread winding machine which could load,wing,clamp,cut and unload sewing thread.The system can improve efficiency of winding and the program can be read easily.%针对普通缝纫线绕线机自动化程度低、对操作者熟练程度要求高等问题,设计了一种基于可编程逻辑控制器( Pro-grammable Logic Controller,PLC)顺序功能图( Sequential Function Chart,SFC)的缝纫线绕线机自动控制系统,有效提高了缝纫线绕制的效率与自动化程度。根据缝纫线绕线机结构组成,分析绕线机基本原理及工作流程,利用SFC逻辑清晰的优点,完成自动控制系统的设计和编程,开发一种能够自动完成上料、绕线、夹线、断线和下料等功能的缝纫线绕线机自动控制系统,具有绕线效率高、程序可读性好等特点。

  6. Automatic Differential Principle and Control Strategy for 4WID-EV%4WID-EV的自动差速原理及控制策略

    Institute of Scientific and Technical Information of China (English)

    何竞松; 陈世元

    2013-01-01

    Focusing on the limitation of the research on differential driving of four wheels independent drive electric vehicle (4WID-EV), which always takes power wheels as research object and neglects the effect of internal force adjustment of vehicle chassis, this paper establishes a vehicle longitudinal dynamics mathematical model with chassis internal force and tire lateral force. Automatic differential principle for 4WID-EV is studied through detailed analysis of the forces imposed on each wheel in the model and the control strategy of "suboptimal torque combination" is formulated. The virtual sample of the vehicle is constructed in Automatic Dynamic Analysis of Mechanical Systems (ADAMS) and its mathematical model, differential and control performance are verified through simulation. Results show that the mathematical model is accurate and able to improve the automatic differential and control performance of the vehicle.%针对研究四轮独立驱动电动汽车差速行驶问题时仅以动力轮为研究对象而忽略车架内力调节作用的局限性.建立含有车架内力和车轮侧向力的汽车纵向动力学数学模型.通过对模型中各车轮的受力细分,研究四轮独立驱动电动汽车的自动差速原理,并制定“次最优转矩组合”的控制策略.在ADAMS中构建该车辆虚拟样机并对其数学模型、差速性能、控制性能进行仿真验证.结果表明,数学模型准确,车辆的自动差速性能和控制性能更佳.

  7. Automatic process control for pipeline: an ally in the quest for excellence in quality; Controle automatizado do processo de revestimento de dutos: um aliado na busca da excelencia em qualidade

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Christian E.; Santos, Paulo T.; Nunes, Matheus; Sartori, Marcio [Soco Ril do Brasil S.A., Pindamonhangaba, SP (Brazil); Populin, German [Soco-Ril da Argentina S.A. (Argentina); Ferreira, Joaquim C. [Tenaris Confab, Pindamonhangaba, SP (Brazil)

    2004-07-01

    Process is any specific combination of machines, methods, tools and people which aim to obtain products or services with high quality. Any changing in one of these elements may result in another process. The concern in assuring its control totally owe to the necessity of having quickly answers related to the standards deviation. Herewith, it is possible to get as much uniformity as possible from that quality characteristic. Through a thickness automatic controlled system it may be possible to evaluate in real time the process itself, identifying tendencies of sequential or temporal performance. Therefore it is possible to act instantaneously adjusting the process, complying with client's specification. The present paper describes the applicability of a automatic controlled system and shows the advantages of its using. (author)

  8. 基于LM PLC控制的太阳能自动跟踪系统%Solar Energy Automatic Tracking System Based on LMPLC Control

    Institute of Scientific and Technical Information of China (English)

    范战松

    2011-01-01

    solar panel automatic tracking system based on PLC is introduced. The hardware of the system includes the input and output port of the PLC,signal processing unit and driving part. The software includes PLC control and monitor program.%介绍基于PLC的太阳能电池板自动跟踪系统,其中硬件包括PLC输入输出端口、信号处理单元、驱动部分;软件包括PLC的控制和监控程序两部分。

  9. MATHEMATICAL MODEL OF TRANSIENT PROCESSES PERTAIN-ING TO THREE-IMPULSE SYSTEM FOR AUTOMATIC CONTROL OF STEAM GENERATOR WATER SUPPLY ON LOAD RELIEF

    OpenAIRE

    G. T. Kulakov; A. T. Kulakov; A. N. Kukharenko

    2014-01-01

    The paper analyzes an operation of the standard three-impulse automatic control system (ACS) for steam generator water supply. Mathematical model for checking its operational ability on load relief has been developed in the paper and this model makes it possible to determine maximum deviations of water level without execution of actual tests and any corrections in the plants for starting-up of technological protection  systems in accordance with water level in the drum.  The paper reveals rea...

  10. Design of Automatic Programming System of Numerical Control Based on AutoCAD%基于AutoCAD数控自动编程系统的设计*

    Institute of Scientific and Technical Information of China (English)

    高杰; 袁吉; 邵振威

    2013-01-01

    AutoCAD作为目前主流的绘图软件广泛应用于很多领域,其强大的功能为数控自动编程提供了基础。该系统的建立主要基于VBA与AutoCAD系统中ActiveX自动化对象模型两者之间的结合,从而对AutoCAD进行内部二次开发,即以ActiveX自动化对象模型为基础建立了前置处理模块;利用Access建立加工参数数据库系统和数据库检索系统,并建立了数控自动编程系统,使AutoCAD具备一定的CAM功能,达到改善现有数控车床自动编程环境的目的。%AutoCAD, as current mainstream graphics software, is widely used in many fields. Its powerful features provide basis for automatic programming of numerical control. The establishment of this system is mainly based on integration of be-tween ActiveX automation object model and VBA which belong to AutoCAD system. AutoCAD is made internal secondary development: establishing pre-processing module based on ActiveX automation object model; building processing parameter database systems and database retrieval system by using Access, and establishing NC automatic programming system, which make AutoCAD have some CAM functions and achieve objects of improving automatic programming environment of existing numerically controlled lathe.

  11. 原油处理过程中自动控制系统的应用%On Automatic Control System Applied to Crude Oil Processing

    Institute of Scientific and Technical Information of China (English)

    陈志刚

    2015-01-01

    随着老油田的持续开采 ,生产的原油含水量不断上升 ,对油、水、气的分离技术要求越来越高 ,采用的工艺也较复杂.为此,开展了利用自动控制系统处理油、气、水分离过程的探讨.从介绍原油处理过程、工作参数、油水分离及油气分离原理入手,对油、气、水自动控制分离装置的组成、功能和原理进行了阐述 ,并以油、气分离装置为例对工作介质要求、自动调节过程等进行了说明 ,论证了自动控制系统在原油处理过程中的应用价值.%Continuously rising of water content of crude oil in maturing oilfield asks for higher isolation technology of oil ,water and gas and more complex processing .This paper ,accordingly ,explores how to apply automatic control system to isolation processing of oil ,water and gas .Starting with the introduction of crude oil processing and its working parameters and the principle of oil-water separation and oil-gas separation ,this paper explains the auto-matic oil-gas-water separating unit in terms of its components ,functions and principles ,followed by the illustra-tion of its working medium and self regulating process .The application value of the automatic control system in crude oil processing is also demonstrated .

  12. The design of automatic washing machine control system based on Proteus%基于Proteus的全自动洗衣机控制系统设计

    Institute of Scientific and Technical Information of China (English)

    刘晓彤

    2012-01-01

    This paper mainly discusses using the Proteus simulation software to achieve the automatic washing machine control system hardware,software simulation design,debugging and running.This design,which uses a AT89S52 MCU as the control core and a washing machine as a control object,controls the entire laundry process by apply corresponding input and output device.This paper introduces the design for a automatic washing machine control scheme in a convenient and efficient way.The scheme uses software electric circuit and the automatic washing machine control system software program both designed by the Proteus simulation software,and then add the prepared program to a virtual prototype based on the hardware schematic,finally achieve the real-time debugging and simulation running of both hardware and software.%本文主要探讨采用Proteus仿真软件,实现全自动洗衣机控制系统硬件、软件的仿真设计和调试运行。本设计采用AT89S52单片机作为控制核心,以洗衣机作为控制对象,采用相应的输入、输出设备,实现对洗衣机整个洗衣过程的多种控制。本文介绍了从方便、快捷的角度出发进行的全自动洗衣机控制方案设计,使用Protues仿真软件进行的硬件电路设计,全自动洗衣机控制系统软件程序的设计,最后在基于硬件原理图的虚拟原型上添加编写好的程序,实现了硬件、软件的实时调试和仿真运行。

  13. The Application of Virtual Machine in Automatic Control System%浅谈虚拟机在自动控制系统中的应用

    Institute of Scientific and Technical Information of China (English)

    王守毅

    2014-01-01

    在现代工业生产过程中,人们开始大量使用自动控制系统。而在自动控制系统的使用中,人们大量采用了虚拟机。文中将首先介绍虚拟机的概念和发展现状,然后讨论使用虚拟机具有的好处。简要地叙述了虚拟机的安装,以及虚拟机在厦门烟草工业责任有限公司RPC系统更新中的应用。%In modern industrial processes, people begin widely use of automatic control systems. In the widely use of the automatic control system, people also begin use a large number of virtual machines. This article will first introduce the concept and development status of virtual machine, and then discuss the benefits of using virtual machine. Then I will Briefly describes how to install the virtual machine, and the virtual machine used in Xiamen tobacco limited liability company’s RPC system update.

  14. 基于忆阻器的自动增益控制电路设计%Design of Automatic Gain Control Circuit Based on Memristor

    Institute of Scientific and Technical Information of China (English)

    王勤; 甘朝晖; 段宗胜

    2013-01-01

    忆阻器被认为是除了电阻、电容、电感之外的第四个基本电路元件,它是一种非线性二端无源器件,具有“记忆”功能.忆阻器在众多领域中具有巨大的应用潜力,有望推动整个电路理论的变革.介绍了一种改进的忆阻器SPICE模型,在此基础上,设计了一种基于忆阻器的自动增益控制电路.通过SPICE对电路进行仿真,证明该设计是可行的,完全实现了增益的自动控制.%Memristor is considered as the forth basic circuit element besides resistor, capacitor and inductor. It is a two-terminal non-linear passive component with memory function. Memristors have great potential applications in many fields, and it is expected to change the theory of circuit greatly. An improved memristor model was presented and an automatic gain control (AGC) circuit was designed based on memristor. The proposed circuit was simulated with SPICE. Simulation results showed that the circuit could fully realize automatic gain control.

  15. LabVIEW应用于自动控制系统的内存管理%LabVIEW Used in the Automatic Control System Memory Management

    Institute of Scientific and Technical Information of China (English)

    赵静; 张宁宁

    2014-01-01

    介绍了几种LabVIEW编程内存优化的方法,文中以自动控制系统为例,介绍了在进行自动控制系统编程时所要注意的几个方面。此外,本文还介绍了几个有用的内存检查工具。很好地应用这些方法,能够提高程序的运行效率,便于程序的内存管理。%This paper describes several methods about LabVIEW programming memory optimization. Based on the automatic control system, introduction is given on several aspects in programming the automatic control system:dynamic invocation VI;mandatory use of type conversion;memory leak prevention; array memory allocation; using global variables and so on. In addition, the paper describes several useful memory checkers. These methods can improve the operating efficiency of the program and make the program' s memory management easier.

  16. Application of automatic control technology in the gas field development%自动控制技术在气田开发中的应用

    Institute of Scientific and Technical Information of China (English)

    黄湛

    2014-01-01

    Southwest oil and gas ifeld company is the PetroChina Co Ltd regional Corporation, after more than 50 years of natural gas development, Automatic control technology in the application of sichuan and chongqing gas ifeld development also from the point to the surface, in promoting the management level, reduce labor intensity, improve production efifciency, reducing the personnel allocation play an increasingly important role . In this paper automatic control technology in the application status of gas field development, problems and solutions are discussed.%西南油气田公司是中国石油天然气股份有限公司的地区公司,经过50多年的天然气开发,自动控制技术在川渝气田开发中的应用也由点到面,在提升管理水平、降低劳动强度、提高生产效率、减少人员配置方面起着日益重要的作用。本文就自动控制技术在川渝气田的应用发展历程、应用现状、存在问题及解决方案进行了探讨。

  17. 基于模糊 PID 自动转向控制系统的研究%Automatic Steering Control System Research on Fuzzy PID

    Institute of Scientific and Technical Information of China (English)

    张长龙; 李文春; 马蓉; 任玲; 石翔

    2016-01-01

    在拖拉机自动转向控制系统中,为了提高自动转向性能,满足工作需求,设计了参数自整定的模糊 PID控制。同时,对模糊控制规则进行了设计,实现对PID3个输出比例因子进行实时修改,提高了系统的控制性能。对模糊PID 在MATLAB中进行了建模仿真,通过仿真结果可以看出:该控制方法有很好的稳态精度和自适应能力,明显改善了系统的动态特性,有利于拖拉机自动驾驶精度的提高。通过台架实验,验证了该控制方法的可行性。%Tractor automatic steering control system , to improve the automatic steering performance ,meet the job require-ments, design the parameter self-tuning fuzzy PID control .Design and implementation of fuzzy control rules and modify the PID three output scaling factor in real time ,improve the control performance of the system .And the fuzzy PID has car-ried on the modeling and simulation in MATLAB, the simulation results can be seen that this control method has good steady precision and adaptive ability , obviously improve the dynamic characteristic of the system , beneficial to the im-provement of the tractor automated driving accuracy .

  18. Investigation of Matlab® as Platform in Navigation and Control of an Automatic Guided Vehicle Utilising an Omnivision Sensor

    Directory of Open Access Journals (Sweden)

    Ben Kotze

    2014-08-01

    Full Text Available Automatic Guided Vehicles (AGVs are navigated utilising multiple types of sensors for detecting the environment. In this investigation such sensors are replaced and/or minimized by the use of a single omnidirectional camera picture stream. An area of interest is extracted, and by using image processing the vehicle is navigated on a set path. Reconfigurability is added to the route layout by signs incorporated in the navigation process. The result is the possible manipulation of a number of AGVs, each on its own designated colour-signed path. This route is reconfigurable by the operator with no programming alteration or intervention. A low resolution camera and a Matlab® software development platform are utilised. The use of Matlab® lends itself to speedy evaluation and implementation of image processing options on the AGV, but its functioning in such an environment needs to be assessed.

  19. Investigation of Matlab® as platform in navigation and control of an Automatic Guided Vehicle utilising an omnivision sensor.

    Science.gov (United States)

    Kotze, Ben; Jordaan, Gerrit

    2014-08-25

    Automatic Guided Vehicles (AGVs) are navigated utilising multiple types of sensors for detecting the environment. In this investigation such sensors are replaced and/or minimized by the use of a single omnidirectional camera picture stream. An area of interest is extracted, and by using image processing the vehicle is navigated on a set path. Reconfigurability is added to the route layout by signs incorporated in the navigation process. The result is the possible manipulation of a number of AGVs, each on its own designated colour-signed path. This route is reconfigurable by the operator with no programming alteration or intervention. A low resolution camera and a Matlab® software development platform are utilised. The use of Matlab® lends itself to speedy evaluation and implementation of image processing options on the AGV, but its functioning in such an environment needs to be assessed.

  20. Electronic amplifiers for automatic compensators

    CERN Document Server

    Polonnikov, D Ye

    1965-01-01

    Electronic Amplifiers for Automatic Compensators presents the design and operation of electronic amplifiers for use in automatic control and measuring systems. This book is composed of eight chapters that consider the problems of constructing input and output circuits of amplifiers, suppression of interference and ensuring high sensitivity.This work begins with a survey of the operating principles of electronic amplifiers in automatic compensator systems. The succeeding chapters deal with circuit selection and the calculation and determination of the principal characteristics of amplifiers, as

  1. Crude unit automatic crude switch control using. Multivariable predictive control technology; Joatsu joryu sochi no gen`yu kirikae jidoka. Tahensu seigyo to kisetsu seigyo system ni yoru saiteki unten

    Energy Technology Data Exchange (ETDEWEB)

    Ageishi, N. [Yamatake-Honeywell Co. Ltd., Tokyo (Japan)

    1998-06-01

    This paper describes automatic crude oil switching control for normal pressure distilling equipment used in oil refineries. Crude oil has been switched several times a week, where an operator has made adjustment manually at each time of the switching. Operation frequency was high, much labor was required, and loss was produced due to excess quality. The present attempt has realized an optimum operation by introducing multivariable crude oil switching technology and combining it with the existing advanced control technology. Because the realized technology automatically detects the crude oil switching which does not require input of yield data of crude oil to be processed based on a production plan, there is no need of TBP slope estimation, and control mode switching by an operator based thereon, or feed-forward by using data of crude oil nature. The technology is also capable of dealing with crude oil switching having large yield variation. Operating conditions are adjusted automatically based on the nature estimation, hence no manual adjustment is required. Loss due to excess quality can be minimized. Time to adjust the switching can be decreased. Effectiveness of this system was verified in a wide range from normal operation to unsteady state in crude oil switching. 3 refs., 6 figs., 2 tabs.

  2. 全自动刨煤机组集中控制系统的设计%Design of Central Control System of Full Automatic Plough Unit

    Institute of Scientific and Technical Information of China (English)

    刘永刚; 刘召安; 姚立权

    2012-01-01

    为实现刨煤机组全自动集中控制,系统采用光缆技术、现场总线技术、集中控制技术,不仅可实现井下视频控制和地面控制,并可实现泵站设备、转载机、破碎机、刮板输送机、带式输送机等刨煤机组所有设备的联机控制和保护。重点描述了刨煤机组集中控制系统的设计原理。%In order to realize automatic and centralized control of plough unit, cable technology, field bus technology and centralized control technology are all used in the system. The system can realize underground video control, ground control and the online control. All plough unit equipment, such as pumping station, reversed loader, crusher, scraper conveyor and belt conveyor can be controlled and protected. It focused on the design principle of centralized control system of plough unit.

  3. 红外感应节电器在教室照明中的应用%Application of infrared illumination automatic control equipment in university classroom

    Institute of Scientific and Technical Information of China (English)

    洪涛; 王力军

    2012-01-01

    某校教学楼宇和教室多,学生上课或者上自习没有固定教室,长明灯等浪费电导致电能损耗过大,为解决这一问题,引入了红外感应照明自动控制设备,通过制定相应控制策略,使得耗电量下降,而且减少了后期和电工管理成本.%The university teaching buildings and classrooms lamp waste electrical leads electric energy loss too large due to the students attend classes or study having no fixed classroom, in order to solve this problem, the paper introduces the infrared illumination automatic control equipment, through the development of the corresponding control strategy, decreasing power consumption and electrician management cost.

  4. Control system design on the plane battery automatic heating simulation%飞机蓄电池自动加温仿真控制系统设计

    Institute of Scientific and Technical Information of China (English)

    杨萍; 高运奎; 李召华

    2012-01-01

      为确保飞机蓄电池在低温下的正常工作,基于数字温度传感器DS18B20设计了蓄电池自动加温设备的控制系统。软件运行可靠,达到理想的控制效果。%  To ensure normal work of the plane battery in low temperature, Based on the digital temperature sensor DS18B20 control system of the battery automatic heating equipment was designed. Software operation was reliable,so as to achieve the ideal control effect.

  5. [Use of steam-oxygen tents with a universal steam generator and automatic control system in the treatment of acute stenosing laryngotracheitis in children].

    Science.gov (United States)

    Taĭts, B M

    1993-01-01

    To treat acute stenosing laryngotracheitis in acute respiratory viral infection in children an original method has been developed and used for 2 years in a special hospital department. The method implies treatment of children in steam-and-oxygen tents with a universal steam-moistening generator and automatic control system. A controlled study of 50 children with acute laryngeal stenosis degree I-III confirmed high efficacy of this method permitting improvement of blood oxygenation, gas composition, acid-base condition, reduction of acidosis, prevention of exicosis and brain edema. Warm humid atmosphere promoted better discharge of the secretion and better functioning of the ciliated epithelium. Combined treatment incorporating the tents in acute laryngeal stenoses reduced lethality in severe cases, number of intubations and tracheostomies, of complications resultant from parenteral administration of the drugs. PMID:8009767

  6. Design of automatic pattern laser-cutting system based on DSP control%花样激光自动裁剪系统的DSP控制

    Institute of Scientific and Technical Information of China (English)

    蒋水秀; 张森林; 殷建军

    2012-01-01

    To achieve high speed clothing cutting with high control precision, the control system for cutting automatically by laser is developed. Taking advantages of digital signal processor TMS320F2812's rich hardware resources, the system improved laser cutting technology and tangent motion interpolation algorithm. Based on laser cutting principle and general design ideas of auto-cutting system, the mechanical structure with hardware and software is developed for the cutting control system. It involved secure digital card storage and FAT32 file management process, realizing the transmission of files for trajectory control. The results indicated that this automatic laser-cutting system fulfils cutting more exactly and efficiently. Compared with conventional products, it deleted the vibration from mechanical cutter, meanwhile improving the work efficiency and quality for clothing cutting or pattern cutting.%为实现服装面料优质高效裁剪,引入激光裁剪技术,采用具有丰富外设资源的DSP处理器TMS320F2812,运用正切运动插补算法,研发激光自动裁剪控制系统.依据激光裁剪原理和自动裁剪系统的总体设计,完成结构设计和硬件设计,同时配合软件设计,应用SD卡存储及FAT32文件管理程序,实现轨迹控制文件的传输.结果表明:激光自动裁剪系统具有高精度、高效率的裁剪效果.克服了传统机械裁剪刀具切削引起的震动,不但提高了面料或花样裁剪的质量,而且也提高了裁剪效能.

  7. Design of automatic control system for antigravity casting equipment%反重力铸造设备自动控制系统的设计

    Institute of Scientific and Technical Information of China (English)

    王艳珍; 邹蕾; 朱登飙

    2016-01-01

    According to the actual control needs of the antigravity casting equipment,an automatic control system for anti⁃gravity casting equipment was designed by means of modern automatic control technology. The overall design of the system,hard⁃ware selection and software design were accomplished. The digital PID control method is used to improve the system’s self⁃com⁃pensation ability and anti⁃interference ability. The Ziegler⁃Nichols method is used to set the digital PID parameters. The setting results were tested with the heat adjustment test. The test results show that the system has reliable operation,good curve tracking performance,and can achieve the application requirement.%根据反重力铸造设备实际控制的需要,运用现代自动控制技术设计一种反重力铸造设备自动控制系统,完成系统的总体设计、硬件选型与软件设计。运用数字PID控制方法对提高系统自补偿能力与抗干扰能力,通过Ziegler⁃Nichols方法对数字PID参数进行整定,对结果通过热调试验进行测试。结果表明,系统运行可靠,曲线跟踪性能良好,达到使用要求。

  8. Automatic Control System of Direct Tension-type Pilot Cold Rolling Mill%直拉式冷轧实验机自动控制系统

    Institute of Scientific and Technical Information of China (English)

    李建平; 杨红; 牛文勇; 王国栋

    2012-01-01

    为了满足钢铁企业加强冷轧生产技术研究能力的需要,轧制技术及连轧自动化国家重点实验室(RAL)自主设计开发了垂直方向采用液压自动厚度控制(HAGC),水平方向两侧通过液压缸和夹头产生张力进行自动张力控制(ATC)的新型直拉式可逆冷轧实验轧机.概要地介绍了直拉式冷轧实验机的设备构成及设备的主要功能和特点,详细说明了控制系统构成及自动控制功能的实现,通过系统测试给出了系统控制精度.测试结果表明冷轧实验工艺过程可以模拟生产工艺过程,进行冷轧钢种开发和工艺研究.%To meet iron and steel enterprises requires to strengthen research capacity in cold-rolled production technology, State Key Laboratory of Rolling and Automation(RAL) independently designed and developed a new direct tension-type pilot cold rolling mill, which includes a vertical hydraulic automatic gauge control(HAGC) generating tension through the hydraulic cylinders and chucks on both sides o{ the horizontal direction to realize automatic tension control (ATC). The equipment constitute, main functions and features of direct tension-type pilot cold rolling mill were introduced briefly. The control system structure and the realization of automatic control functions were illustrated. The control precisions were gotten through system testing. The testing results showed that the experimental process may simulate the cold roiling production process to develop steel grade and research technology.

  9. Optimization of the Automatic Control Process to Improve CDQ Power Generation%优化自动化控制过程提高干熄焦发电量

    Institute of Scientific and Technical Information of China (English)

    李金凤; 孔德恩

    2015-01-01

    自动化控制系统是确保焦炉、干熄焦、发电各生产环节的稳定运行的重要保障,而优化和改进自动控制系统对提高干熄焦发电的经济效益有重要作用。总结了干熄焦自动控制系统的特点及其重要的优化节点的优化措施。%The automatic control system is an important guarantee for stable operation of the production process flow from coke oven and dry quenching to waste heat power generation; and optimization and improvement of the automatic control system plays an important role in improving the economic benefits of CDQ power generation. The characteristics of CDQ automatic control system and optimization measures for important control nodes are summarized.

  10. 步进式加热炉自动控制系统设计%The Design of Walking Beam Furnace Automatic Control System

    Institute of Scientific and Technical Information of China (English)

    解韶峰; 崔桂梅; 李爱莲

    2014-01-01

    本文针对包钢无缝厂ȼ180机组步进式加热炉进行自动控制改造。步进式加热炉自动控制系统包括物料传输控制系统和加热工艺过程控制系统两部分,前者以开关量为主,多属于电气控制;后者以模拟量为主,属于过程控制。论文构建了基于现场总线的网络化系统方案,并进行了具体的软硬件设计工作,对炉膛温度采取了模糊串级双交叉控制策略,增强了系统的稳定性和抗干扰的能力,且电气和过程控制共用一套PLC,大大节约了硬件建设的成本。%The thesis discusses automatic control's reform in allusion to the walking beam furnace in plant unit ȼ180 of Baotou steel seamless factory.walking beam furnace Automatic Control System includes two parts of material transmission control system and the heating process control system.The former gives priority to switching value,and most of it belongs to electrical control.The latter gives priority to analog quantity,belongs to process control.Paper structures networked system solutions based on profibus,and has carried on specific work on soft-hardware design.takes the way of fuzzy series double-crossing control about FBT(furnace box temperature).The system stability and anti-jamming capability enhanced largely.Besides the electrical control and process control share one set of PLC,so that the cost of hardware construction was saved greatly.

  11. Automatic voltage regulation of synchronous generator using generalized predictive control; Ippanka yosoku seigyo wo mochiita doki hatsudenki no jido den`atsu chosei

    Energy Technology Data Exchange (ETDEWEB)

    Funabiki, S.; Yamakawa, S. [Okayama University, Okayama (Japan). Faculty of Engineering; Ito, T. [Nishishiba Electric Co. Ltd., Hyogo (Japan)

    1995-02-28

    For the automatic voltage regulator (AVR) of a synchronous generator, various applications of self-tuning digital control (STC) have been experimented which successively adjusts PID gains to cope with dynamic characteristics such as disturbances of a plant. As one of such applications, a proposal has been made in this paper for a stable and highly adaptable control system by using a generalized predictive control as the control law and the sequential least-square method as the identification method. An experiment was carried out by a simulation and an experimental AVR, and the effectiveness was confirmed of this control method. The following points may be listed in summarizing the characteristics of this AVR. The arithmetic time is short, and a highly accurate identification value is obtainable. Since an oblivion coefficient is determined by the supremum trace gain method, the adaptability is increased on the parameter identification value. A stable control is obtained even if a plant is a non-minimum phase system. 10 refs., 11 figs., 2 tabs.

  12. Research of automatic gain control technology based on photomultipliers%基于光电倍增管的自动增益控制技术研究

    Institute of Scientific and Technical Information of China (English)

    汪锋; 孙开江; 向小梅

    2015-01-01

    为了压缩水下无线光通信系统中接收光信号的动态范围、提高有效通信距离,从自动增益控制技术的基础理论入手,利用光电倍增管增益可随工作电压改变的特性,设计出基于光电倍增管实现的自动增益控制电路,其数字控制部分以单片机为核心,并在空气中模拟水下实验。结果表明,该电路可以对接收光信号实现40dB的压缩,提高了水下无线光通信的有效范围。%In order to compress the dynamic range of the received optical signal in an underwater optical wireless communication system and increase the effective distance of communication , automatic gain control circuit based on variable gain photomultipliers was designed from the basic theory of automatic gain control technology .Single chip microcomputer was the core of the digital control part .The underwater experiment was imitated in the air .The results show that the dynamic range of received optical signal is compressed for 40dB and the effective range of underwater wireless optical communication is improved .

  13. Design of Controller for Automatic Tracking Solar Power Generation%全天候太阳能自动跟踪系统装置的研究

    Institute of Scientific and Technical Information of China (English)

    郑锋; 王炜灵; 陈健强; 陈泽群; 张晓薇

    2014-01-01

    本文提出了一种全天候太阳能自动跟踪系统。在检测系统上,硬件方面使用实际的光电跟踪模型,软件上设置视日运动轨迹跟踪程序;在控制系统上,采用双轴跟踪的机械传动机构,通过驱动直流电机调整太阳能板的最佳位置,并通过传功装置实现单台电机带动整排太阳能电池板的联动;针对阴雨天和狂风天气控制系统做出一系列的预防措施。本装置旨在全天采光发电,结构简单、能耗低、效率高。%The principle and structure of an intelligent automatic solar tracker are proposed. For testing system, a modelofphotoelectric tracing as hardware is used to track light while the device sets up a program to analysis the movement of the light as software. For controlling system, the controller has a two-axis tracker for mechanical design,and promote the whole row of solar panel linked by linkage. The controller drives the stepping motor to adjust the position of the solar panel to follow the sunlight,and. Other actions are taken to avoid the rain and strong wind. And the intelligent energy-saving design is involved. The simple-designed and energy-saving automatic tracking solar power generation is expected to work in days with highly efficiency.

  14. Development of basic technology for instrumentation and control - Development of digital automatic supervisory limitation system and its design= validation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jung In; Chung, Sung Wook; Koh, Won Seok [Kyungwon University, Sungman (Korea, Republic of); Suh, Duk Young; Cheon, Sei Young [Kyunghee University, Seoul (Korea, Republic of); Lee, Sang Kyung; Kim, Sung Hun [Seoul National University, Seoul (Korea, Republic of)

    1995-07-01

    A major objective of the project is to develop a digital automatic supervisory limitation system and validate its design for the next generation= nuclear power plant. The limitation system assures that the plant does not exceed the operating limits by regulation the plant operations through on-line monitoring the operating margins of the critical parameters. A new conceptual model of power maneuverability has been proposed for the design of the limitation system and for its validation. Also, the limitation system monitors overall operation processes throughout a nuclear power plant by implementing hierarchical communication networks. Based on the conceptual design in software of the 1 st year results, the detailed design of the limitation system has been performed during the 2 nd year with constructing a prototype digital system. The system consists of the software module for plant simulation and the hardware module for implementation of limitation system and the associated interfaces in hardware. The limitation algorithm were implemented into the microprocessor and the interfaces were realized through the I/O modules. Also, these modules are incorporated into the communication networks. The products of the project could be directly applicable to the following nuclear unit adopting the limitation system, providing the bumpless transition to the commercial design phase. And the prototype evaluation scheme will be very useful for the succeeding studies related to the digital nuclear I and C fields, such as fault-tolerance design methods, software verification and validation and response time execution of digital systems. 69 refs., 3 tabs., 44 figs. (author)

  15. 1150mm可逆冷轧机液压自动控制系统%Automatic Control System of 1 150 mm Reversible Cold Rolling Mill

    Institute of Scientific and Technical Information of China (English)

    王孝科; 张海军; 薛风春

    2011-01-01

    介绍1 150mm单机架冷轧机自动控制系统的硬件配置、软件配置和传感器配置,说明液压自动控制系统的位置闭环控制原理和压力闭环控制原理,重点阐述厚度控制系统中的前馈AGC、监控AGC、流量AGC和加减速厚度补偿.现场实际应用表明:成品相对厚度精度优于±1%,超差长度大大缩短,满足了实际生产的要求.%Hardware, software and sensor configuration of automatic control system for 1150 nun single stand cold rolling mill were introduced. Principles of position close loop control and rolling force close loop control in automation control system of rolling mill were explained. Feed forward AGC, monitoring AGC, mass flow AGC and gauge compensation during acceleration and deceleration in gauge control system were described in detail. Practical application shows that relative thickness accuracy of products is within ± 1% , the ultra-poor length is shortened greatly and it meets the need of practical production.

  16. Research on Power Plant Steam Boiler Automatic Control System Based on Fuzzy Control%基于模糊控制的电厂蒸汽锅炉自动控制系统研究

    Institute of Scientific and Technical Information of China (English)

    周继春

    2013-01-01

      针对电厂发电过程中需对蒸汽锅炉进行自动控制的目的,提出了采用模糊控制原理实现蒸汽锅炉压力和温度的自动控制方案。通过深入研究火力发电厂中的蒸汽锅炉的工作循环过程,建立了蒸汽锅炉内部压力和温度的工作模型。文章详细设计了电厂蒸汽锅炉自动控制系统的总体方案,重点研究了模糊控制模块的设计原理和实现方法,给出了模糊控制中的隶属函数和各个主要变量的模糊化过程。最后通过仿真测试,分析了锅炉自动控制系统的工作性能。%Aiming at the automatic control aim in power plant generating electricity, this paper put forward a automatic control scheme steam boiler pressure and temperature, on fuzzy control principle. By further studying the steam boiler circulation process in thermal power plant, it built a steam boiler inner pressure and temperature working model. It design the power plant steam boiler automatic control system overall scheme in detail, focused on the design principle and implementation method, presented the membership function and main variables in the fuzzy process. At last, by simulation test, it analyzed the steam boiler control system working performance.

  17. Clothes Dryer Automatic Termination Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    TeGrotenhuis, Ward E.

    2014-10-01

    Volume 2: Improved Sensor and Control Designs Many residential clothes dryers on the market today provide automatic cycles that are intended to stop when the clothes are dry, as determined by the final remaining moisture content (RMC). However, testing of automatic termination cycles has shown that many dryers are susceptible to over-drying of loads, leading to excess energy consumption. In particular, tests performed using the DOE Test Procedure in Appendix D2 of 10 CFR 430 subpart B have shown that as much as 62% of the energy used in a cycle may be from over-drying. Volume 1 of this report shows an average of 20% excess energy from over-drying when running automatic cycles with various load compositions and dryer settings. Consequently, improving automatic termination sensors and algorithms has the potential for substantial energy savings in the U.S.

  18. Automatic measure & control system of X-ray diffraction goniometer%X射线衍射定向仪自动测控系统

    Institute of Scientific and Technical Information of China (English)

    王悦敏; 钱力鹏; 杜彦从

    2001-01-01

    介绍了X射线衍射定向仪的工作原理,并对X射线衍射定向仪的自动测控系统的设计进行了描述。目前该测控系统测量人造单晶晶体晶面角时,测量精度能达到20″,接近国际领先水平。%This paper describes the design of Automatic Measurement &Control System of X Ray Diffraction Goniometer. It has an originally hardware design with I2C bus,rapid A/D convert module and high precision rotary encoder. And that make it high accuracy(about 20″)and high extensibility (easy to change many functions without changing the hardware).

  19. T型管自动焊机适时控制系统设计%Design of Timely Controlling System of T-Shape Automatic Welding Machine

    Institute of Scientific and Technical Information of China (English)

    苗雨来; 梁楚华; 周建平; 高军义

    2012-01-01

    In order to improve the welding quality of T-shape automatic welding machine for the welding process, according to phenomenon of the actual welding path which can not fit the theoretical definition of the path,an optical detection system is researched and designed to achieve the timely detection of the actual weld location and feedback to achieve timely control purposes.The system is used to detect the actual location of horizontal pipe and vertical pipe deformation of T-shape work-piece which is mainly caused by punch accuracy or thermal deformation in the welding process ,and then achieve timely control function of the T梥hape automatic welding machine.The system has achieved good results in the production, ensuring the welding quality,and improves the welding efficiency of radiator pipe welding;it is a key technology for the development o/T-shape automatic welding machine.%为了提高T型管自动焊机的焊接质量,针对焊接过程中,实际焊接路径不能与理论定义路径吻合的问题,研究并设计出一套光电检测系统,用来实现对实际焊缝位置的适时检测与反馈,达到适时控制的目的.系统主要是对焊接过程中,由于打孔精度或者热变形等因素造成的T型管焊件横向管与纵向管变形后焊缝实际位置的适时检测,从而实现T型管自动焊机适时控制的功能.该系统在钢制散热器管道焊接生产中取得了良好的效果,很好的保证了焊接质量,并提高了焊接效率,是T型管自动焊机发展的一项关键技术,是T型管自动焊机发展的一项关键技术.

  20. Modularity, adaptability and evolution in the AUTOPIA architecture for control of autonomous vehicles. Updating Mechatronics of Automatic Cars

    OpenAIRE

    Pérez Rastelli, Joshué; González, Carlos; Milanés, Vicente; Onieva, Enrique; Godoy, Jorge; Pedro, Teresa de

    2009-01-01

    International audience Computer systems to carry out control algorithms on autonomous vehicles have been developed in recent years. However, the advances in peripheral devices allow connecting the actuator controllers to the control system by means of standard communication links (USB, CAN, Ethernet ... ).The goal is to permit the use of standard computers. In this paper, we present the evolution of AUTOPIA architecture and its modularity and adaptability to move the old system based on IS...

  1. “自动控制原理”虚拟实验系统开发%Development of Automatic Control Theory Virtual Experiment System

    Institute of Scientific and Technical Information of China (English)

    王莉; 陈虹

    2011-01-01

    This paper unifies the LabVIEW virtual instrument development environment and the merit of Matlab software,which has a high-performance on technical computing,based on automatic control theory and experiments.The following functions have been achieved,which are time domain analysis of linear systems,frequency domain analysis of linear systems,root locus analysis of linear systems,analysis of linear discrete systems,PID lead(lag) correction,motion simulation of a car,and motion simulation of a plane.This method has a friendly man-machine interface and is easy to operate,it is useful to the teaching of "Automatic Control Theory" course,and also makes the interaction between teachers and students easily.%本文结合LabVIEW虚拟仪器开发平台和Matlab软件强大的数值分析功能的优点,立足于"自动控制原理"课程和实验,设计了一套自动控制原理实验仿真系统平台,能够实现线性系统的时域分析、线性系统的频域分析、线性系统根轨迹分析、线性离散系统分析、PID超前(滞后)校正、某汽车的运动仿真和某飞机的运动仿真等功能,该平台有助于"自动控制原理"课程与实验的教学,容易实现教师与学生的互动。

  2. 太阳能电池板自动追光控制系统设计%Design of control system for solar panel automatic tracking

    Institute of Scientific and Technical Information of China (English)

    蔺金元

    2012-01-01

    In order to use solar-powered, a system that solar panel can automatic track the sun is produced. The system use combined method of solar movement tracking and maximum power point seeking, it controls solar energy conversion utilization device automatically and rotated it to aim at the sun, and it can raise the solar energy absorption rate. In the system, single- chip microcomputer is used as the controller, small solar battery is used as sensor, and stepper motor is used as actuating mechanism. The system has some practical value for devices which rely on the solar energy.%为实现太阳能供电,介绍了一种太阳自动追踪系统.该系统采用视日运动跟踪与寻求最大功率点相结合的方法,控制太阳能转换利用装置自动旋转去对准太阳,能有效提高太阳能的吸收率.该系统采用单片机作为控制器,小型太阳能电池作为传感器,步进电机作为执行机构.对于各种利用太阳能作为能源的自动装置而言.这种自动追踪系统具有一定的实用价值.

  3. Automatic Control Design of Rust Removing Device for Pipe End%管端除锈设备自动控制设计

    Institute of Scientific and Technical Information of China (English)

    李建明; 邓志伟; 付雪强; 张世平; 江渊; 魏耀华

    2012-01-01

    In this article, it introduced the structure and functions of a new kind of SAW pipe end rust removing device, and expounded its working principle. At the same time, the full-automatic control technology of rust removing was designed based on SIEMENS S7-200 PLC. The productive practice proved that this automatic control design increased production efficiency, reduced failure rate and work labor cost, avoided unstable factors of manual operation, and realized stable rust removing quality.lt was in favour of HSE field management, and simple maintenance. Meanwhile, it avoided base metal scratch, increased rust removing quality. So it is applicable to widely promote in SAWH pipe industry.%介绍了一种新型螺旋埋弧焊管管端除锈设备的构造和功能,阐述了其工作原理,并基于西门子S7-200 PLC设计了除锈设备的全自动控制工艺.经过实际生产应用证明,管端除锈设备的自动控制设计提高了工作效率,维修、维护方便,故障率降低,更有利于HSE现场管理,避免了人工操作的不稳定因素,降低了劳动力成本,保证了管端除锈质量的稳定,同时,避免了母材划伤,提高了除锈质量,在同行业中具有很好的推广应用价值.

  4. Design and Implementation of Control System of Automatic Girth Welding Machine%环缝自动焊机控制系统设计与实现

    Institute of Scientific and Technical Information of China (English)

    2013-01-01

    Aiming at problems existing in automatic girth welding motor control system, SCM of STC 89C52RC is used as a control core, the original circuit is improved, control system is upgraded, increase the human-computer interaction device and the memory function of stepper motor memory function are added. All these reduce labor intensity of worker; improve the control precision, welding quality and stability. Thus the system consume is reduced and the business cost is saved.%  针对环缝自动焊机控制系统存在的问题,采用STC 89C52RC单片机为控制核心,改进原有的电路,升级控制系统,引入人机交互装置,增加了步进电机的记忆功能,减轻了工人劳动强度,提高了环缝自动焊机的控制精度、焊接质量和工作稳定性,降低了系统功耗,为企业节省了成本。

  5. Design of Fully Automatic Hatching Control System and Its Implementation%全自动孵化控制系统的设计与实现

    Institute of Scientific and Technical Information of China (English)

    于水娟; 李振璧

    2012-01-01

    According to the demand of modern incubation industry, we design and implement automatic regulation and control system for the oxygen levels, temperature and humidity of incubator, using AT89C51 single — chip as the main controller, through the keyboard by default, control resistance wire heating, humidifier humidifying and complete cooling fan, drop wet etc. The actual operation shows that hatching rate increased significantly and weak young rate to decline significantly. The structure of system is simple, reliability and high control accuracy and it has certain practical value and the development prospect.%根据现代孵化行业的需求,设计并实现了对孵化器温湿度、含氧量的自动调节与控制,使用AT89C51单片机作为主控器,通过键盘预设,控制电阻丝加热、加湿器加湿以及风机完成降温、降湿等功能;实际运行结果表明出雏率明显提高,弱雏率明显下降;系统结构简单、可靠性和控制精度较高,具有一定的实用价值和发展前景.

  6. 光纤预制棒接管的自动控制研究%The research of automatic control optical fiber preform welding

    Institute of Scientific and Technical Information of China (English)

    邵金涛; 王新箭; 满小忠; 沈国锋; 程遥

    2013-01-01

    According to the equipment modification project, briefly introduced the automatic control system's realization method of the optical fiber preform welding process. The system uses Mitsubishi PLC and touch panel to replace the existing manual operation mode. Meanwhile the system's speed control temperature control will be greatly improved. In addition the system also added the CCD temperature testing device, to provide a more reliable judgment for the system. The actual production conditions show that the control system improves the product quality and greatly reduce the labor intensity.%根据设备改造项目实例,简要介绍了光纤预制棒接管自动控制系统的实现方法.该系统采用三菱PLC和威纶通触摸屏代替原有的手动操作模式,提高了系统中速度控制和温度控制的精确性和稳定性.同时系统增加了CCD温度检测,为程序控制提供了更加可靠的判断条件.实际生产表明:该控制系统提高了光棒预处理的产品质量,大大减轻了劳动强度.

  7. Automatic Turnout Control System Based on Time Game Automata%基于时间博弈自动机的道岔自动控制系统

    Institute of Scientific and Technical Information of China (English)

    余兴超; 董荣胜; 孙栋栋; 邵梅

    2012-01-01

    为提高道岔自动控制系统的运行效率,引入时间博弈自动机理论,建立列车、控制器、道岔和故障检测器的时间博弈自动机网络模型,使用TCTL公式描述获胜条件,应用策略综合工具Uppaal-Tiga输出获胜策略并生成控制代码.仿真结果表明,该控制策略可以有效提高列车的行车效率.%In order to enhance the efficiency of automatic turnout control system, this paper introduces the theory of time game automata, builds the networks of time games automata models of train, controller, turnout, fault detector, gives the winning condition specified by TCTL formula, outputs the winning strategy synthesized by tool Uppaal-Tiga and generates the control code. Simulation results indicate that the control strategy enhances the efficiency of trains.

  8. Controller design for automatic micro-assembly systems under the influence of surface forces, hysteresis and quantizer

    NARCIS (Netherlands)

    Ouyang, Ruiyue; Jayawardhana, Bayu

    2011-01-01

    In this paper, we design nonlinear controllers for micro-magnetic levitation systems. The controller takes into account the influence of the surface forces and hysteresis/quantizer. We show the exponential convergence of the error signal and its time derivative to a compact set, which is determined

  9. Automatic personnel contamination monitor

    International Nuclear Information System (INIS)

    United Nuclear Industries, Inc. (UNI) has developed an automatic personnel contamination monitor (APCM), which uniquely combines the design features of both portal and hand and shoe monitors. In addition, this prototype system also has a number of new features, including: micro computer control and readout, nineteen large area gas flow detectors, real-time background compensation, self-checking for system failures, and card reader identification and control. UNI's experience in operating the Hanford N Reactor, located in Richland, Washington, has shown the necessity of automatically monitoring plant personnel for contamination after they have passed through the procedurally controlled radiation zones. This final check ensures that each radiation zone worker has been properly checked before leaving company controlled boundaries. Investigation of the commercially available portal and hand and shoe monitors indicated that they did not have the sensitivity or sophistication required for UNI's application, therefore, a development program was initiated, resulting in the subject monitor. Field testing shows good sensitivity to personnel contamination with the majority of alarms showing contaminants on clothing, face and head areas. In general, the APCM has sensitivity comparable to portal survey instrumentation. The inherit stand-in, walk-on feature of the APCM not only makes it easy to use, but makes it difficult to bypass. (author)

  10. Implementation of Automatic Test System on PXI for Flight Control System%飞控PXI型自动测试系统的实现

    Institute of Scientific and Technical Information of China (English)

    罗秋凤; 肖前贵

    2011-01-01

    For the automatic test requirement of unmanned aircraft flight control system with many kinds、 many test-points、 high-power range , and wide measuring range singals, this paper presents a automatic test system (ATS) on PXI bus.Topology model design is implemented to switch network in test unit adapter (TUA) of the ATS, including three kinds of mapping configration for UUT &power supply、 test-points & instruments, and test-points & multimeter junctions matching.Because of the design for switch neitwork self-adaptive model, one ATS can be satisfied with automatic testing requirement for all airborne devices, instead of 8 sets of traditional manned test equipments.The ATS has also such characteristics as fault on-line diagnosis, high accuracy up to 4 and 1/2 FLUKE multimeter, and nopaperlog.During the UAV field flight verification, the maintenance speed is reduced to one-twentieth than in the past. The ATS has been put into engineering uses.%为解决无人机飞行控制系统的多种类、多测点、宽功率、宽量程信号的自动检测要求,研制了一台基于PXI总线技术的自动检测系统·将拓朴模型化的设计思想应用到接口适配器组件的开关网络,分别设计了电源开关阵、测点测试开关阵、万用表端子开关阵的控制模型,建立了测点与供电电源和测试资源间的映射拓扑关系,将飞行控制系统全部机载设备的性能测试集中在一台测试系统中,取代了传统的8台套专用分证型手动测试设备;该自动检测系统具有自动检测、在线故障诊断处理、电子记录等功能,测试精度达到了FLUKE万用表四位半的精度,机务准备与维护速度降低到原来的二十分之一,并已投入了工程应用.

  11. Design of Air Conditioning System and Automatic Control for Vaccine Hatch Room%疫苗孵房空调系统及自控设计

    Institute of Scientific and Technical Information of China (English)

    朱晔

    2015-01-01

    孵房是疫苗生产过程中重要的场所,其对环境的要求比较高。为生产水痘减毒活疫苗,根据该疫苗的生产条件要求,设计了一套空调系统及控制流程。该系统的运行特性表明,该系统的温度控制在(37±0.5)℃,湿度控制在45%~65%。孵房的净化级别可以达到C级,符合该疫苗的生产条件要求。%Hatch room is the important space for vaccine production, and demands a high quality of environment. In the present study, an air conditioning system and the automatic control process for the production of varicella attenuated live vaccine was designed based on requirement of the production conditions. The operation performance of this system shows that, the temperature is controlled within (37±0.5)oC and the humidity is controlled within 45%~65%. The purity of air can reach up to level C, which is in accordance with the requirement of production conditions.

  12. Towards unifying inheritance and automatic program specialization

    DEFF Research Database (Denmark)

    Schultz, Ulrik Pagh

    2002-01-01

    Inheritance allows a class to be specialized and its attributes refined, but implementation specialization can only take place by overriding with manually implemented methods. Automatic program specialization can generate a specialized, effcient implementation. However, specialization of programs...... with covariant specialization to control the automatic application of program specialization to class members. Lapis integrates object-oriented concepts, block structure, and techniques from automatic program specialization to provide both a language where object-oriented designs can be e#ciently implemented...

  13. AUTOMATIC GLUCOSE INSULIN REGULATION SYSTEM-COMPARISON OF EMBEDDED CONTROL DESIGN AND HARR WAVELET METHOD FOR TYPE-1 DIABETES

    Directory of Open Access Journals (Sweden)

    R. Arangasamy

    2014-01-01

    Full Text Available This article is aimed to inject insulin for type 1 diabetes using pumping the insulin with respect to meal disturbance. We have used the embedded linear parameter varying methodology controller and the final results were compared with the Harr wavelet mathematical values. In this article, there are three things we need to focus. First is the sensor values which is to be monitored from the sensors and next is the lab information. Depending on the patients test details the insulin has to be injected. The comparison of lab details with the Patients current sensor values play a vital role in determining the insulin level for a patient. Finally the feedback has to be obtained with the help of those comparisons and it has to be sent once again as a loop to the controller for later comparison and also for database information. The embedded controller is the key element for updating all the information about the patient and it will control all the parameters of the board. The experimental results shows that the proposed method has much better potential in terms of solution accuracy as 97% and better convergence speed in comparison with Haar Wavelet Model which proved 89.09% of accuracy of the assured values of our experiments.

  14. An investigation into the relevance of action planning, theory of planned behaviour concepts, and automaticity for fruit intake action control

    NARCIS (Netherlands)

    G.J. de Bruijn; A. Wiedemann; R.E. Rhodes

    2014-01-01

    Objectives In the action control framework, intention-behaviour discordance is studied around public health guidelines. Although this framework has been applied to physical activity behaviours, it has only seen very limited attention regarding fruit intake. The purpose of this study was therefore to

  15. Measurement and automatic control techniques at sewage treatment plants. Concepts, experience, trends.. Manuscripts and posters; Mess- und Regelungstechnik in abwassertechnischen Anlagen. Konzepte, Erfahrungen, Trends. Manuskripte und Poster-Praesentationen

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-31

    This conference volume on measurement and automatic control techniques at sewage treatment plants deals with the following subjects: online analytics, measurement techniques and control techniques; use of model-assisted techniques; transparency and acceptance, plant management; process control concepts; optimization of operation. (SR) [Deutsch] Themen dieses Konferenzbandes ueber Mess- und Regelungstechnik in abwassertechnischen Anlagen sind: Online-Analytik, Mess- und Stelltechnik; Einsatz modellgestuetzter Verfahren; Transparenz und Akzeptanz, Betriebsmanagement; Leittechnische Konzepte; Betriebsoptimierung. (SR)

  16. Television system for automatic control of electrode position during argon arc welding of large-sized components

    International Nuclear Information System (INIS)

    The article deals with a TV system designed for controlling the position of electrode during argon-arc welding of butt joints with deep bevelling (levelling depth exceeds 10 mm). The operation of the system is based on the processing of bevelling images. The application of the system ensures the travel of the electrode along bevelling axis with an accuracy ±1 mm, minimum. 2 refs., 3 figs

  17. Control device for automatic orientation of a solar panel based on a microcontroller (PIC16f628a)

    Science.gov (United States)

    Rezoug, M. R.; Krama, A.

    2016-07-01

    This work proposes a control device for autonomous solar tracker based on one axis, It consists of two main parts; the control part which is based on "the PIC16f628a"; it has the role of controlling, measuring and plotting responses. The second part is a mechanical device, which has the role of making the solar panel follows the day-night change of the sun throughout the year. Both parties are established to improve energy generation of the photovoltaic panels. In this paper, we will explain the main operating principles of our system. Also, we will provide experimental results which demonstrate the good performance and the efficiency of this system. This innovation is different from what has been proposed in previous studies. The important points of this system are maximum output energy and minimum energy consumption of solar tracker, its cost is relatively low with simplicity in implementation. The average power increase produced by using the tracking system for a particular day, is over 30 % compared with the static panel.

  18. 浅析污染源自动监控数据质量控制与应用%Analysis on Pollutant Source Automatic Monitoring and Controlling Data Quality Control and Its Application

    Institute of Scientific and Technical Information of China (English)

    黄梅

    2013-01-01

      As the country's economic development, industrialization and urbanization accelerated, expanded space for economic development, but the concomitant environmental pollution problems are becoming more serious and increasing pressure on resources and environment for sustainable development. The Party Central Committee and the State Council has put environmental protection on the more important strategic position, vigorously develop the pollutant source automatic monitoring system construction. This article focused on how to strengthen the quality control of pollutant source automatic monitoring data, improve data accuracy, legitimacy, in order to fully apply environmental management and full play the pollutant source automatic monitoring and controlling the effectiveness of the system.%  随着国家经济的发展,工业化和城市化加速,扩大了经济发展空间,但伴随而来的环境污染问题也日益严重,可持续发展的资源和环境压力日益加剧。党中央、国务院把环境保护摆上了更加重要的战略位置,大力发展污染源自动监控系统建设。本文主要探讨如何加强污染源自动监控数据质量控制,提高数据的准确性、合法性,以全面应用于环境管理,切实发挥污染源自动监控系统的效用。

  19. Automatic optimisation of beam orientations using the simplex algorithm and optimisation of quality control using statistical process control (S.P.C.) for intensity modulated radiation therapy (I.M.R.T.)

    International Nuclear Information System (INIS)

    Intensity Modulated Radiation Therapy (I.M.R.T.) is currently considered as a technique of choice to increase the local control of the tumour while reducing the dose to surrounding organs at risk. However, its routine clinical implementation is partially held back by the excessive amount of work required to prepare the patient treatment. In order to increase the efficiency of the treatment preparation, two axes of work have been defined. The first axis concerned the automatic optimisation of beam orientations. We integrated the simplex algorithm in the treatment planning system. Starting from the dosimetric objectives set by the user, it can automatically determine the optimal beam orientations that best cover the target volume while sparing organs at risk. In addition to time sparing, the simplex results of three patients with a cancer of the oropharynx, showed that the quality of the plan is also increased compared to a manual beam selection. Indeed, for an equivalent or even a better target coverage, it reduces the dose received by the organs at risk. The second axis of work concerned the optimisation of pre-treatment quality control. We used an industrial method: Statistical Process Control (S.P.C.) to retrospectively analyse the absolute dose quality control results performed using an ionisation chamber at Centre Alexis Vautrin (C.A.V.). This study showed that S.P.C. is an efficient method to reinforce treatment security using control charts. It also showed that our dose delivery process was stable and statistically capable for prostate treatments, which implies that a reduction of the number of controls can be considered for this type of treatment at the C.A.V.. (author)

  20. Research on the impact of pollutants on the automatic transmission control method%污染物对自动变速器的影响与控制方法研究

    Institute of Scientific and Technical Information of China (English)

    孙炜; 高佩

    2014-01-01

    本文详细论述了自动变速器中的污染物形成根源及对自动变速器的危害,分析了目前变速箱中应用的清洁度标准,从而提出了控制污染的措施。%Discuss reasons of pollutant in the automatic transmission and the damage of pollutant in the automatic transmission, analysis cleanliness standard of transmission, and propose control pollution measures.

  1. A simple, digitally controlled, automatic, hysteresis free, high precision energy scanning system for Van de Graaff type accelerators. Pt. 1

    International Nuclear Information System (INIS)

    A digitally controlled energy scanning system is described which may be coupled in a simple and inexpensive way to any accelerator which is high voltage stabilized by a beam position sensing 'slit control' system like all single ended or tandem Van de Graaff type machines. The basic idea is to 'fool' the existing stabilization system by deflecting the beam at two well chosen points through small angles using electrostatic deflection plates biased to variable voltages U. It is shown that the ensuing terminal potential variation δV is linearly related to U, the system acting as a U -> δV closed loop feedback amplifier with a gain G0 set only by the beam trajectory in the analyzing magnet and between the plates. G0 is hence independent of acceleration potential, beam particle mass or charge state, the long term stability of G0 being set only by mechanical components. The calibration can thus be made once and for all. The system is strictly hysteresis free and provides means of varying the bombarding energy in small precisely equal steps in a fast and reproducible way. (orig./WL)

  2. Development of plant-level automatic voltage control system for power plant%火电厂厂级自动电压控制系统研制

    Institute of Scientific and Technical Information of China (English)

    翟伟翔; 周宇华; 苏适; 刘友宽

    2011-01-01

    An integrated AVC(Automatic Voltage Control) substation is developed based on existing plant -level automatic generation control system for power plant. The gain of adaptive PID adjuster is properly modified by the dynamic identification of system impedance and the voltage and reactive power are online switched for realizing the error-free and quick adjustment. The bias adjustment algorithm is put forward based on traditional equivalent power factor distribution and reactive power capacity coefficient distribution and the calculation formulas are given. Technical issues of parameter collection, operating mode and protective blocking are described for practical application. Site operation proves that,the proposed AVC system operates stably and reliably with flexible operating manner, good adjustment property and perfect security mechanism.%为保证电网安全、优质、经济运行,将火电厂自动电压控制在现有厂级自动发电控制系统平台上扩展实施,构成了一体化专用子站.通过动态辨识系统阻抗,适当修正自适应PID调节器的增益,进行电压和无功的在线转换,实现无差、快速调节.在传统的等功率因数分配方法与无功容量系数分配方法基础上提出了偏置调整算法,给出了计算公式.针对实际应用,阐述了参数采集、运行模式、闭锁保护等方面的技术问题.通过电厂的实际运行,证明该系统能够稳定可靠地工作,并具有操作方式灵活、调节品质较好、故障与安全处理机制完善等特点.

  3. [The automatization of the control over the processes determining the risk of HIV-infection spreading among servicemen].

    Science.gov (United States)

    Lobzin, Iu V; Churnosov, E V; Bolekhan, V N; Zigalenko, D G; Karapats, M M

    2005-07-01

    The possibilities of the control over the processes determining the HIV-infection spreading risk are considered. In the view of that the automated system which enables to evaluate risk factors predetermining the appearance of new infection cases was proposed. These factors are systematised in a multilevel database. On the basis of the statistical analysis of the risk factors situations of the spread of the HIV infection are revealed and analysed and measures for their liquidation are worked out promptly. The system is universal and can be used for the prevention of the beginning of other extreme situations caused by the spread of different infections. The examples of the comparative analysis of the risk of sexual behaviour in various groups of servicemen are given. PMID:16134377

  4. Disain dan Implementasi Kontrol PID Model Reference Adaptive Control untuk Automatic Safe Landing pada Pesawat UAV Quadcopter

    Directory of Open Access Journals (Sweden)

    Teddy Sudewo

    2012-09-01

    Full Text Available Pada fase penerbangan quadcopter, fase landing (pendaratan merupakan fase paling kritis, dimana resiko terjadi kecelakaan paling besar. Permasalahan tersebut muncul karena adanya beberapa kendala, seperti kendala pada struktur rangka pesawat yang kecil, peningkatan beban pada sayap pesawat serta pengaruh angin sehingga menyebabkan pesawat tidak stabil. Pada penelitian tugas akhir ini, didesain suatu sistem kontrol pada UAV quadcopter menggunakan kontrol PID dengan Model Reference Adaptive Control (MRAC. Sistem pengendalian berbasis MRAC menawarkan beberapa kelebihan untuk mengatasi karakteristik plant non-linear salah satunya quadcopter. MRAC merupakan kontrol adaptif dimana performansi keluaran sistem (proses akan mengikuti performansi keluaran model referensinya. Pada tugas akhir ini, model referensi sudah ditentukan diawal dan spesifikasinya tetap sehingga dapat langsung didisain mekanisme adaptasi dari MRAC. Parameter proses θ (a1,a2,b0,b1 diestimasi menggunakan metode Extended Least Square, parameter proses tersebut akan mentuning parameter kontroler (k0,k1,k2,k3 sehingga menghasilkan sinyal kontrol PID. Hasil pengujian menunjukkan bahwa ketika terjadi perubahan parameter pada plant, kontroler mampu memperbaiki respon agar tetap dapat mengikuti model referensinya dan dalam mengatasi gangguan metode adaptasi MRAC memiliki kemampuan yang baik dilihat dari waktu yang dibutuhkan yang relatif singkat.

  5. Chinese 100 RAM PLC Automatic Controlling System of Flushing%国产百元PLC自动冲水控制系统

    Institute of Scientific and Technical Information of China (English)

    钟承尧; 王红晨; 颜丽娜

    2012-01-01

    Automatic controlling system of flushing is composed of Chinese 100 RAM PLC with single chip microcontroller STC89C52RC as its controlling core, proximity sensor and magnetic valve as the output- terminal executing device. The hardware and controlling program are designed in this paper. The practical application more than one year demonstrates that the system is of high sensitivity and high stability. Meanwhile, the circuit of hardware is so simple that it is easy to maintain. In the aspect of software,the ladder program will be applied in different places once modified a little, and therefore the system is of good universality and low cost. In total, the system saves water and there will be good prospect.%以STC89C52RC单片机为控制核心的国产百元PLC,采集信号的接近开关传感器和输出执行器件电磁阀,组成了自动冲水控制系统。设计了硬件电路及控制程序;经过一年多时间的实际应用,系统灵敏度高、稳定性好、硬件电路简单、易于维护。梯形图程序稍作修改便可用于不同场所,通用性强,成本低,节约水资源,具有很好的应用前景。

  6. Algorithms for skiascopy measurement automatization

    Science.gov (United States)

    Fomins, Sergejs; Trukša, Renārs; KrūmiĆa, Gunta

    2014-10-01

    Automatic dynamic infrared retinoscope was developed, which allows to run procedure at a much higher rate. Our system uses a USB image sensor with up to 180 Hz refresh rate equipped with a long focus objective and 850 nm infrared light emitting diode as light source. Two servo motors driven by microprocessor control the rotation of semitransparent mirror and motion of retinoscope chassis. Image of eye pupil reflex is captured via software and analyzed along the horizontal plane. Algorithm for automatic accommodative state analysis is developed based on the intensity changes of the fundus reflex.

  7. An experimental study of visual flight trajectory tracking and pose prediction for the automatic computer control of a miniature airship

    Science.gov (United States)

    Haecker, Jens; Kroeplin, Bernd H.

    2003-08-01

    This paper describes our current work in developing a vision-based tracking and trajectory prediction system for an aerial robot based on low-cost digital cameras, image processing techniques, and a filtering and prediction algorithm. The system determines the pose (location and orientation) of a miniature airship, online during indoor flight, and will be used in a development framework for a future autonomous flight control system. Object localization is achieved by tracking an infra-red target array mounted to a model airship. Its pose in three-dimensional space can be computed from corresponding points in the images of two cameras which are calibrated in a global coordinate system. The calibration procedure and the localization, as well as some aspects of the measurement accuracy achieved, are discussed. Real-world applications provide an uncertain static or dynamic environment which complicates the tracking of a target. To overcome problems due to noisy data or even failed target detection in image frames, a filtering procedure is applied for estimating the airship's pose. In a first step, points in the two-dimensional image planes are directly tracked and propagated forward to the vehicle pose. In a second step, an adaptive noise Kalman filter is applied for estimating and predicting the flight trajectory. Its state is propagated back to points in the image planes to guide the detection algorithm by defining regions of confidence. Both approaches are combined in a tracking algorithm. In-flight measurements are used to validate the parameters of the adaption procedure. Some experimental results are shown.

  8. The in vivo relationship between cross-sectional area and CT dose index in abdominal multidetector CT with automatic exposure control

    Energy Technology Data Exchange (ETDEWEB)

    Meeson, S; Alvey, C M; Golding, S J, E-mail: stuart.meeson@nds.ox.ac.u [Radiology Group, Nuffield Department of Surgery, University of Oxford, John Radcliffe Hospital, Oxford OX3 9DU (United Kingdom)

    2010-06-15

    The relationship between patient cross-sectional area and both volume CT dose index (CTDI) and dose length product was explored for abdominal CT in vivo, using a 16 multidetector row CT (MDCT) scanner with automatic exposure control. During a year-long retrospective survey of patients with MDCT for symptoms of abdominal sepsis, cross-sectional areas were estimated using customised ellipses at the level of the middle of vertebra L3. The relationship between cross-sectional area and the exposure parameters was explored. Scans were performed using a LightSpeed 16 (GE Healthcare Medical Systems, Milwaukee, WI) operated with tube current modulation. From a survey of 94 patients it was found that the CTDI increased with the increase in patient cross-sectional area. The relationship was logarithmic rather than linear, with a least-squares fit to the data (R{sup 2} = 0.80). For abdominal CT the cross-sectional area gave a measure of patient size based on the region of the body to be exposed. Exposure parameters increased with increasing cross-sectional area and the greater radiation exposure of larger patients was partly a consequence of their size. Given increasing obesity levels we believe that cross-sectional area and scan length should be added to future dose surveys, allowing patient size to be considered as a factor of relevance when examining population doses.

  9. A 100-m Fabry–Pérot Cavity with Automatic Alignment Controls for Long-Term Observations of Earth’s Strain

    Directory of Open Access Journals (Sweden)

    Akiteru Takamori

    2014-08-01

    Full Text Available We have developed and built a highly accurate laser strainmeter for geophysical observations. It features the precise length measurement of a 100-m optical cavity with reference to a stable quantum standard. Unlike conventional laser strainmeters based on simple Michelson interferometers that require uninterrupted fringe counting to track the evolution of ground deformations, this instrument is able to determine the absolute length of a cavity at any given time. The instrument offers advantage in covering a variety of geophysical events, ranging from instantaneous earthquakes to crustal deformations associated with tectonic strain changes that persist over time. An automatic alignment control and an autonomous relocking system have been developed to realize stable performance and maximize observation times. It was installed in a deep underground site at the Kamioka mine in Japan, and an effective resolution of 2 × (10−8 − 10−7 m was achieved. The regular tidal deformations and co-seismic strain changes were in good agreement with those from a theoretical model and a co-located conventional laser strainmeter. Only the new instrument was able to record large strain steps caused by a nearby large earthquake because of its capability of absolute length determination.

  10. 660MW Unit Heating Steam Pressure Automatic Control Strategy Study%660MW机组供热蒸汽压力自动控制策略研究

    Institute of Scientific and Technical Information of China (English)

    孟娜

    2015-01-01

    热电联产集中供热比分散供热可以减少燃煤对环境的污染,具有明显的环境效益。马鞍山当涂发电有限公司对2×660MW机组进行供热改造,供热系统采用压力匹配器方案,利用压力匹配器匹配出满足要求的蒸汽。压力匹配器出口压力是供热蒸汽压力品质最重要参数,文章对实现压力匹配器出口压力自动控制策略进行了分析介绍。%CHP with district heating produces less coal-fired pollution on the environment than decentralized heating , it has obvious environmental benefits.Maanshan Dangtu Power Generation Co., Ltd. heating system uses pressure matching device program, using a pressure matching device to let the steam meet the requirements.The outlet pressure of pressure matching device is the most important parameter of heating steam pressure quality.This thesis introduced the automatic control strategy of the outlet pressure of pressure matching device .

  11. Discussion of Automatic Control Valve Model Selection for Coal Gasification Working Condition%煤气化工况自控阀门选型探讨

    Institute of Scientific and Technical Information of China (English)

    刘志伟

    2013-01-01

    Automatic control valve plays a crucial role for the stable running of coal gasification plant. The water slurry gasification process is briefly described. The harsh conditions for coal slurry valve, oxygen valve, synthesis gas venting valve, lock slag valve, black water valve are evaluated according to the process characteristic. Based on the successful operating experience of same process, the valve design selection is discussed primarily. The advice on valve type, material, internals, sealed level and special treatment are given. It provides reference for instrument selection of similar process apparatus.%煤气化装置运行稳定与否,自控阀门起着关键的作用.简要介绍了水煤浆气化工艺,根据其工艺特征分别分析了煤浆阀、氧气阀、合成气放空阀、锁渣阀、黑水阀的严酷工况.依据同行业成功运行经验,重点对以上阀门的设计选型进行探讨,对阀门形式、材质、内件、密封等级及特殊处理给出了建议,为同类工艺装置的仪表选型提供了参考依据.

  12. Design of Automatic Control System for Plasma Nitriding%离子渗氮自动控制系统的设计

    Institute of Scientific and Technical Information of China (English)

    唐红文; 何翔; 陈锟

    2001-01-01

    给出了基于单片机的等离子体渗氮工艺自动控制系统的设计方案,该系统由PIC单自机、AI智能仪表及脉冲电源等组成,对该系统组成部分的功能和监控程序设计作了详细地说明,该系统实现了对等离子体渗氮工艺的自动控制,为现行离子渗氮的设备发行和该工艺的技术进步将起到重要的作用。%In this paper, a design of automatic control system for plasma nitriding is introduced.The system includes PIC single chip microcontroller,AI intelligent instrument and pulse power.It is discussed that the function of the system and monitoring program.

  13. Application of Intelligent Automatic Control System for Greenhouse%关于智能温室自动控制系统的应用探究

    Institute of Scientific and Technical Information of China (English)

    南书明

    2014-01-01

    The facility agriculture takes greenhouse as the key. The experience on the domestic and international greenhouse cultivation has proved that optimizing the greenhouse system and enhancing automatic control capabilities and management level of greenhouse can give full play the efficiency of greenhouse agriculture. This paper described the characteristics of greenhouse in the present stage, and expounds how to optimize and widely apply greenhouse in detail.%设施农业是将温室作为重点,国内外的温室种植上的丰富经验证明,对于温室系统的优化,提升温室的自动控制能力及管理水平能够将温室农业具有的高效性充分的发挥出来。本文针对我国现阶段温室所具有的特点进行了说明,并且如何优化,广泛的应用进行了详尽的阐述。

  14. Over-exposure correction in knee cone-beam CT imaging with automatic exposure control using a partial low dose scan

    Science.gov (United States)

    Choi, Jang-Hwan; Muller, Kerstin; Hsieh, Scott; Maier, Andreas; Gold, Garry; Levenston, Marc; Fahrig, Rebecca

    2016-03-01

    C-arm-based cone-beam CT (CBCT) systems with flat-panel detectors are suitable for diagnostic knee imaging due to their potentially flexible selection of CT trajectories and wide volumetric beam coverage. In knee CT imaging, over-exposure artifacts can occur because of limitations in the dynamic range of the flat panel detectors present on most CBCT systems. We developed a straightforward but effective method for correction and detection of over-exposure for an Automatic Exposure Control (AEC)-enabled standard knee scan incorporating a prior low dose scan. The radiation dose associated with the low dose scan was negligible (0.0042mSv, 2.8% increase) which was enabled by partially sampling the projection images considering the geometry of the knees and lowering the dose further to be able to just see the skin-air interface. We combined the line integrals from the AEC and low dose scans after detecting over-exposed regions by comparing the line profiles of the two scans detector row-wise. The combined line integrals were reconstructed into a volumetric image using filtered back projection. We evaluated our method using in vivo human subject knee data. The proposed method effectively corrected and detected over-exposure, and thus recovered the visibility of exterior tissues (e.g., the shape and density of the patella, and the patellar tendon), incorporating a prior low dose scan with a negligible increase in radiation exposure.

  15. Automaticity of walking: functional significance, mechanisms, measurement and rehabilitation strategies

    Directory of Open Access Journals (Sweden)

    David J Clark

    2015-05-01

    Full Text Available Automaticity is a hallmark feature of walking in adults who are healthy and well-functioning. In the context of walking, ‘automaticity’ refers to the ability of the nervous system to successfully control typical steady state walking with minimal use of attention-demanding executive control resources. Converging lines of evidence indicate that walking deficits and disorders are characterized in part by a shift in the locomotor control strategy from healthy automaticity to compensatory executive control. This is potentially detrimental to walking performance, as an executive control strategy is not optimized for locomotor control. Furthermore, it places excessive demands on a limited pool of executive reserves. The result is compromised ability to perform basic and complex walking tasks and heightened risk for adverse mobility outcomes including falls. Strategies for rehabilitation of automaticity are not well defined, which is due to both a lack of systematic research into the causes of impaired automaticity and to a lack of robust neurophysiological assessments by which to gauge automaticity. These gaps in knowledge are concerning given the serious functional implications of compromised automaticity. Therefore, the objective of this article is to advance the science of automaticity of walking by consolidating evidence and identifying gaps in knowledge regarding: a functional significance of automaticity; b neurophysiology of automaticity; c measurement of automaticity; d mechanistic factors that compromise automaticity; and e strategies for rehabilitation of automaticity.

  16. Avaliação do desempenho de um sistema automático para controle da fertirrigação do tomateiro cultivado em substrato Performance evaluation of an automatic system for tomato fertigation control in substrate

    Directory of Open Access Journals (Sweden)

    Antonio J. Steidle Neto

    2009-09-01

    Full Text Available Este trabalho teve por objetivo avaliar o desempenho de um sistema de controle automático de fertirrigação para a produção do tomateiro em substrato de areia, comparativamente ao sistema de controle convencional quanto à redução de solução nutritiva. No método de controle automático, os eventos de fertirrigação foram estabelecidos em função das condições meteorológicas do ambiente de cultivo e do estádio de desenvolvimento da cultura. Para isso, o modelo de Penman-Monteith foi utilizado como suporte para a tomada de decisão sobre a frequência adequada para aplicação da solução nutritiva. No sistema de controle convencional, os intervalos entre as fertirrigações permaneceram fixos durante todo o ciclo do tomateiro. Os resultados demonstraram que o sistema de controle automático atendeu plenamente às necessidades hídricas da cultura, sem comprometer a produção do tomateiro, proporcionando reduções expressivas no consumo de solução nutritiva. Por outro lado, o sistema de controle convencional realizou número excessivo de fertirrigações, principalmente durante o estádio inicial de desenvolvimento do tomateiro e nos dias caracterizados por elevada nebulosidade. No estádio inicial de crescimento, verificou-se que os volumes totais de solução nutritiva, aplicados ao tomateiro pelo sistema convencional, excederam as necessidades hídricas da cultura em 1,31 e 1,39 L planta-1 em dias típicos com céu claro e nublado, respectivamente.The objective of this work was to compare the performance of an automatic fertigation control system, for soilless tomato production in sand substrate, as compared to a conventional control system. In the automatic control, fertigation events were established by meteorological conditions in the cultivation environment and crop development stage. In this way, the Penman-Monteith model was utilized as a decision support tool regarding the appropriate frequency for delivering the

  17. Emotional Regulation of Implicitly Measured Stereotypes:Automatic and Controlled Processes%情绪对内隐刻板印象表达的调节

    Institute of Scientific and Technical Information of China (English)

    王沛; 王雪枫; 陈庆伟

    2015-01-01

    Emotion for a long time has been thought as the main reason causing the cognitive obstinacy of the stereotype and the stereotype expression. However, researches discussing directly how emotion regulates expression of implicitly measured stereotypes are few. Relevant researches so far only discussed the effect of diffuse moods and there were differences and disputes in specific experimental results and theoretical explanation. In the light of the deficiency of the previous researches this study improves the relevant theory of emotional regulation of implicitly measured stereotypes expression through two series of experiments based on the clarification of the definition and classification of the emotion. Experiment 1 employs music to awake different diffuse moods (sadness vs. cheer) of the participants and operates their real-time thoughts (stereotype consistent vs. stereotype inconsistent) thus to investigate their influence on implicitly measured stereotypes expression. Experiment 2 employs video to evoke participants' different directional emotions (sympathy vs. dislike), investigating how these regulate college students' implicitly measured stereotypes expression of AIDS patients and HIV carriers of different routes of infection. Series research leads in Quad Model analysis based on IAT paradigm to find out whether the effect of emotional regulation of implicitly measured stereotypes expression happens in automatic processes or controlled processes of cognitive process, and through which psychological elements (AC, OB, D, G) the different emotions regulate implicitly measured stereotypes expression. The results show: (1) When real-time thoughts and stereotype are consistent, positive diffuse moods promote implicitly measured stereotypes expression; Conversely, positive diffuse moods inhibit implicitly measured stereotypes expression; (2) Diffuse moods regulate implicitly measured stereotypes expression by adjusting the automatic processes (AC) of the cognitive

  18. Making the Use of Remote Sensing for Agricultural Subsidy Control More Effective: Automatizing Photo Interpretation of Satellite Imagery over Southern Portugal in the Context of the European Common Agriculture Policy

    Science.gov (United States)

    Schmedtmann, J.; Campagnolo, M.

    2014-12-01

    Control with Remote Sensing (CwRS) is a standardized control method that has been developed by the Monitoring Agriculture Resources (MARS Unit) of the European Commission's Joint Research Centre (JRC). It relies on remote sensing time series data and is officially recognized by the EU as equivalent to actual farm visits. Member states agencies use CwRS to carry out part or all of their on-the-spot controls of EU farms to monitor Common Agriculture Policy (CAP) subsidies. The main component of CwRS is Computer-Aided Photo-Interpretation (CAPI), whose goal is determining the crop occupation of agricultural parcels listed in farmers' subsidies applications. In 2012, the CAP CwRS program enabled the oversight of 349,000 farmers for their area-aid applications, representing 89% of the total EU27 required controls. The goal of this study was to develop a simple and reproducible method to automatize the CAPI process. The main feature of this method is that it allows choosing a confidence level on the automatic classification of farmer's parcels. While higher confidence levels reduce the risk of misclassifications, lower levels increase the number of automatic control decisions that do not require the intervention of a photo interpreter, reducing the overall CwRS costs. We used extensive 2005 validated control data from the Portuguese Control and Paying Agency for Agriculture (IFAP) and a multi-temporal Landsat 7 time series to train and test our methodology. Our overall results indicate that for 95% confidence level, approximately 20% of decisions can be taken automatically and for 80% confidence level the percentage of automatic decisions increases to 55%. For each studied land cover class, the adjacent figure shows the effect of the confidence level on the percentage of parcels that can be classified automatically. Since our approach holds for multiple sensors, we believe that the current results will be further improved with additional data. Our results compare

  19. Coordinated Prevention Based on Manual and Automatic Emergency Control%人工紧急调控与自动紧急控制协同防御

    Institute of Scientific and Technical Information of China (English)

    方勇杰; 鲍颜红; 徐泰山; 徐伟

    2012-01-01

    人工紧急调控是指根据对电网实时状况的分析,由调度员下达控制命令的紧急控制,可为及时消除电网紧急状态发挥关键作用,需要基于不安全现象检测的紧急控制理念,采用基于广域测量系统和能量管理系统信息的紧急调控实时辅助决策技术.。探讨了人工紧急调控与自动紧急控制协同防御的技术路线,包括识别人工紧急调控的可行条件及适用条件、基于实测与仿真结合的辅助决策和保持全局性实时状态觉知能力。结合低频振荡、电压稳定和连锁故障,给出了综合实测信息与仿真计算辅助决策技术的设计思路。%Manual emergency control is based on the analysis of real-time operating conditions of power systems and its control commands are issued by system operators, which can play a key role in the timely elimination of the system emergent, but it should be implemented by combining the concept of emergency control based on detection of insecure phenomena with the real- time decision support technology using wide area measurement system (WAMS) and energy management system (EMS) information. A coordinated preventive roadmap using manual and automatic emergency control is presented, including identification of both the feasibility and applicability conditions of manual emergency control, decision support based on measurement as well as simulation and ability of maintaining overall situational awareness. Design ideas of decision support technology by integrating real-time measurement and simulation analysis are exemplified by using low-frequency oscillation, voltage stability and cascading outages.

  20. Fabrication of thin film x-ray sensor using particle-in-binder method for automatic exposure control in digital radiography

    International Nuclear Information System (INIS)

    An automatic exposure control (AEC) detector is a control device that ensures consistent x-ray image quality and limits patient exposure in digital radiography. Among several kinds of AEC detectors, solid-state sensors offer several advantages such as geometric efficiency due to small thickness, high sensitivity, fast reaction time, and excellent stability. Commercially, the use of single-crystal silicon sensors for AEC detector has grown over time, but is still severely limited by large-area production techniques and mechanically fragile properties. Therefore, our study focused on developing a method of fabricating solid-state sensors that do not suffer from these limitations. The particle-in-binder method was used to fabricate silicon dioxide-based photoconductor films. Because silicon dioxide has a low atomic number and a low work function, it is a suitable material for generating sufficient electron-hole pairs by incident x-rays as well as not negatively affect the image detector of the digital radiography. To verify the feasibility of the silicon dioxide film as an AEC detector, electrical properties such as x-ray transmission and x-ray linearity were measured and compared with those of a commercialized silicon film. Over 90% x-ray transmission was achieved using a 500 μ m silicon dioxide film, which is suitable for an AEC detector. Also, an error below 3% was obtained from both x-ray current and voltage linearity tests. The results of bending tests demonstrated the properties of the silicon dioxide film to be more mechanically strong and stable compared with the commercialized silicon film. These properties were a result of the use of binder materials, which resulted in the flexibility of the film

  1. Device for common automatic control of a drive unit consisting of an internal combustion engine and a gearbox. Vorrichtung zum gemeinsamen selbsttaetigen Steuern einer aus Verbrennungsmotor und Getriebe bestehenden Antriebseinheit

    Energy Technology Data Exchange (ETDEWEB)

    Kolk, H.J. van der; Minder, R.; Kiess, T.; Muehlich, P.; Adler, K.H.

    1982-03-25

    The purpose of the invention is to develop a device for the common automatic control of a drive unit consisting of an internal combustion engine and a gearbox, so that with different torque requirements the internal combustion engine is always operated at the point of minimum fuel consumption. According to the invention, this problem is solved by the source of the reference value being connected via a first distorter with a fuel dosing device of the internal combustion engine, and the engine having a wellknown tachometer, the output of which is taken to a second input of the control stage via a second distorter. In this way, the invention achieves a common automatic control of the drive unit, by the source of the reference value being made the accelerator pedal and acting via the first distorter on the fuel dosing line.

  2. Automatic exposure control in multichannel CT with tube current modulation to achieve a constant level of image noise: Experimental assessment on pediatric phantoms

    International Nuclear Information System (INIS)

    Automatic exposure control (AEC) systems have been developed by computed tomography (CT) manufacturers to improve the consistency of image quality among patients and to control the absorbed dose. Since a multichannel helical CT scan may easily increase individual radiation doses, this technical improvement is of special interest in children who are particularly sensitive to ionizing radiation, but little information is currently available regarding the precise performance of these systems on small patients. Our objective was to assess an AEC system on pediatric dose phantoms by studying the impact of phantom transmission and acquisition parameters on tube current modulation, on the resulting absorbed dose and on image quality. We used a four-channel CT scan working with a patient-size and z-axis-based AEC system designed to achieve a constant noise within the reconstructed images by automatically adjusting the tube current during acquisition. The study was performed with six cylindrical poly(methylmethacrylate) (PMMA) phantoms of variable diameters (10-32 cm) and one 5 years of age equivalent pediatric anthropomorphic phantom. After a single scan projection radiograph (SPR), helical acquisitions were performed and images were reconstructed with a standard convolution kernel. Tube current modulation was studied with variable SPR settings (tube angle, mA, kVp) and helical parameters (6-20 HU noise indices, 80-140 kVp tube potential, 0.8-4 s. tube rotation time, 5-20 mm x-ray beam thickness, 0.75-1.5 pitch, 1.25-10 mm image thickness, variable acquisition, and reconstruction fields of view). CT dose indices (CTDIvol) were measured, and the image quality criterion used was the standard deviation of the CT number measured in reconstructed images of PMMA material. Observed tube current levels were compared to the expected values from Brooks and Di Chiro's [R.A. Brooks and G.D. Chiro, Med. Phys. 3, 237-240 (1976)] model and calculated values (product of a reference value

  3. 基于PLC的洗碗机的自动控制系统的设计%The Design of the Control System of Automatic Dishwasher Based on PLC

    Institute of Scientific and Technical Information of China (English)

    李庆梅; 瞿新

    2012-01-01

      This paper introduced the automatic dishwasher control system which controls with Mitsubishi FX2N series programmable logical controller(PLC), including system I/0 allocation,PI C wiring diagram and PLC programming,and analyzed the controlled process of program.%  介绍一种用三菱FX2N系列PLC控制的自动洗碗机控制系统,包括系统的I/O端口分配、PLC接线图及PLC程序设计。并详细分析了程序的控制过程。

  4. A Demonstration of Automatically Switched Optical Network

    Institute of Scientific and Technical Information of China (English)

    Weisheng Hu; Qingji Zeng; Yaohui Jin; Chun Jiang; Yue Wang; Xiaodong Wang; Chunlei Zhang; Yang Lu; Buwei Xu; Peigang Hu

    2003-01-01

    We build an automatically switched optical network (ASON) testbed with four optical cross-connect nodes. Many fundamental ASON features are demonstrated, which is implemented by control protocols based on generalized multi-protocol label switching (GMPLS) framework.

  5. 14 CFR 29.1329 - Automatic pilot system.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Automatic pilot system. 29.1329 Section 29... pilot system. (a) Each automatic pilot system must be designed so that the automatic pilot can— (1) Be sufficiently overpowered by one pilot to allow control of the rotorcraft; and (2) Be readily and...

  6. 14 CFR 27.1329 - Automatic pilot system.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Automatic pilot system. 27.1329 Section 27... pilot system. (a) Each automatic pilot system must be designed so that the automatic pilot can— (1) Be sufficiently overpowered by one pilot to allow control of the rotorcraft; and (2) Be readily and...

  7. 智能建筑区门禁系统自动化识别技术分析%Analysis on Automatic Identification Technology of Intelligent Building Access Control System

    Institute of Scientific and Technical Information of China (English)

    张卉

    2015-01-01

    门禁系统是智能建筑区必备设施,可对建筑区提供安全防护、自动调控等多方面功能.指纹识别系统是人工智能改造的新系统,为门禁系统自动识别提供了科技化措施.本文分析了智能建筑发展趋势及指纹识别系统的基本构成,介绍了智能建筑门禁系统自动化识别技术的应用方法.%The access control system of intelligent building is a necessary facility, which provides security protection, automatic control and so on. Fingerprint identification system is a new artificial intelligence system, providing technological measures for the automatic identification of access control system. This paper analyzes the development trend of intelligent building and the basic structure of fingerprint identification system, introduces the application of automatic recognition technology in intelligent building access control system.

  8. General description of automatic variable-load control technique for air separation plant%空分设备自动变负荷控制技术综述

    Institute of Scientific and Technical Information of China (English)

    陈秋霞; 周芬芳

    2011-01-01

    综述国内外大型空分设备的自动变负荷控制技术的发展状况,分析自动变负荷控制技术的难点,着重对空分设备先进控制系统结构和操作流程、模型预测控制基本原理及其在空分领域的研究成果等进行了较全面的阐述,最后对空分设备自动变负荷技术的发展进行了展望。%The development situation of home and abroad automatic variable-load control technique for large-sized air separation plant is briefed, the difficult problems of automatic variable load control technique are analyzed, the structure and operation process of advanced control system for air separation plant, the fundamental principle, model prediction control and its research achievements in air separation field are overall described, and finally the development of automatic load variation technique for air separation plant is prospected.

  9. “自动控制基础”课程研究和改革%Curriculum Reform and Research of Automatic Control Course

    Institute of Scientific and Technical Information of China (English)

    杨慧

    2015-01-01

    为了适应完全学分制要求,笔者对“自动控制基础”课程进行了一系列的改革:从教师自身发展来看,要求其提高理论知识和人文素养;在教学内容安排上设立教学目标,充分结合工程实际;从教学方法方面来看,教师与学生变换角色并充分利用计算机辅助教学;利用网络资源开发网络教学平台;建立新的实验模式等。教学实践证明,这些改革增强了学生学习兴趣,提高了教学质量。%In order to adapt to complete credit system,the author take a series of effective measures to improve the quality of teaching for Principle of Automatic Control course. For one thing,the teacher's theoretical level and teacher's personal charm is introduced. For another,setting a target of teaching from the teaching content arrange-ment fully combined with the engineering practice. Besides,this article put forward some new teaching methods in-cluding the different roles of students and teachers and computer assisting teaching. Teaching practice proves that this teaching methodology could inspire students'learning interest and improve teaching quality effectively.

  10. Research of automatic control system for uitralow frequency vibration calibration%超低频振动校准自动控制系统的研究

    Institute of Scientific and Technical Information of China (English)

    王志鹏; 何闻; 于梅; 沈润杰

    2011-01-01

    针对超低频振动校准过程中测试时间长且效率较低的问题,设计了一种基于个人计算机及虚拟仪器技术开发的超低频振动校准自动控制系统.该系统由超低频标准振动台、功率放大器、激光测振仪、位移传感器、信号发生器、频比计数器、数据采集卡、计算机与测控软件等组成.通过线性逼近与逐步移频相结合的算法,精确控制振动台在超低频时迅速到达设定振级.试验结果证明该系统满足超低频振动校准要求,提高了超低频振动传感器的测试精度和自动化程度.%Aiming at the demerits of time-consuming and low efficiency during the process of ultralow frequency vibration calibration, an automatic ultralow frequency vibration calibration system based on personal computer and virtual instrument was presented.The system was consisted of ultralow frequency standard vibrator, power amplifier, laser vibrometer, displacement transducer, signal generator, universal counter, data acquisition card, computer, control software, etc..The strategy which via combining the method of linear approximation and stepby-step frequency shift could make the vibrator reach the pre-set vibration level quickly and precisely.The experiment results show that the system is suitable for the calibrating ultralow frequency vibration transducers very well and improves the automation of ultralow frequency calibrating vibration.

  11. Research on Clean Coal Clean Coal Technology of Computer Automatic Control%计算机自动控制洁煤净煤技术研究

    Institute of Scientific and Technical Information of China (English)

    杨荣光

    2013-01-01

      在煤利用的过程中,会产生大量有害气体、粉尘等污染物,尤其是在发展中国家,这种污染十分严重。而在当今社会,人们的环保意识逐渐增强,国际上对于煤炭利用带来的环境问题给予了越来越多的关注。广大科技工作者针对洁煤净煤,降低污染方面技术的研究愈加深入,大量新型净化方法和应用技术应运而生。利用计算机自动控制技术,发展煤化工新技术,一方面能更有效地提高经济效益,另一方面能有效地达到洁煤、净煤的效果,保护环境。%  The coal in the use process, will produce a large number of harmful gas, dust and other pollutants, especially in developing countries, this kind of pollution is very serious. In today's society, the people environmental protection consciousness strengthens gradually, the international environment problems caused by coal use to pay more and more attention. Broad Scientists and technologists for clean coal clean coal, reducing pollution technology research more deeply, a new purification method and application technology of emerge as the times require. Use of computer automatic control technology, the development of coal chemical industry new technology, one can more effectively improve the economic benefit, on the other hand, can effectively achieve the clean coal, clean coal, protect environment

  12. 一种适用于网络自同步的时钟控制方法%Clock control method applied to network automatic synchronization

    Institute of Scientific and Technical Information of China (English)

    印晓红; 饶义琼; 罗明阳

    2013-01-01

    Clock synchronization is the precondition of correct and effective data transmission in network communication system,and is widely used in traditional telephone network,IP network,optical network and wireless transmission network. In allusion to the complexity of clock synchronization control used in current networks,a clock control method applied to automatic network synchronization is put forward on the basis of analyzing the principles of network framework,clock control and elastic buffer. The method is based on FPGA,CPU and DDS technologies. Network clock synchronization is implemented in most econo-my consumption by the cooperation of software and hardware. The principle is analyzed. The implemented hardware diagram,FP-GA signal flowsheet and CPU design flowsheet are given in this paper. The method was tested in some equipments and networks. The test results prove that the method is correct,feasible and effective.%时钟同步是网络通信系统中保证数据正确和有效传输的前提,广泛应用于传统电话网络、IP网络、光网络和无线传输网络等。针对目前网络时钟同步控制的复杂性,在分析网络结构、时钟控制和弹性缓冲区原理的基础上,提出一种基于FPGA、CPU和DDS技术的网络自同步时钟控制方法。通过软硬件相结合的处理方式,以最小开销实现网络时钟快速同步。然后对其原理进行了分析,给出实现的硬件框图、FPGA信号流程和CPU设计流程,并在设备和网络中进行了验证,验证结果表明该方法是正确、可行和有效的。

  13. Automatic safety rod for reactors. [LMFBR

    Science.gov (United States)

    Germer, J.H.

    1982-03-23

    An automatic safety rod for a nuclear reactor containing neutron absorbing material and designed to be inserted into a reactor core after a loss-of-flow. Actuation is based upon either a sudden decrease in core pressure drop or the pressure drop decreases below a predetermined minimum value. The automatic control rod includes a pressure regulating device whereby a controlled decrease in operating pressure due to reduced coolant flow does not cause the rod to drop into the core.

  14. 思维导图在自动控制原理教学中的应用%The Application of Mind-Mapping in the Teaching of Automatic Control Principle

    Institute of Scientific and Technical Information of China (English)

    楼旭阳

    2014-01-01

    Mind-mapping, as a new way of thinking tools and learning methods, has generated a significant impact on teaching education. Under the analysis of mind-mapping, this paper pre-liminarily discusses the application of mind-mapping in the teaching of automatic control principle based on the current problems in the classroom teaching of automatic control principle.%思维导图作为一种新兴的思维工具和学习方法,已在教育教学中产生了积极影响。本文在分析思维导图的基础上,结合当前自动控制原理课堂教学存在的问题,初步探讨了思维导图在自动控制原理课堂教学中的应用。

  15. Discussion on Brushless Motor Automatic Control Soft Starter Principle and Its Application%浅谈无刷自控电机软起动器原理及应用

    Institute of Scientific and Technical Information of China (English)

    张宏喜

    2011-01-01

    The paper first introduced the commonly used starting methods of winding motor and its main shortcomings and then the principles and structural character, main performance and typical application effect of brushless automatic control soft starter are introduced. At last, the advantages of brushless motor automatic control soft starter are discussed and the necessity of replacing other types of motor starting device.%本文先简要介绍绕线电机常用的起动方法和存在的主要缺点,后介绍无刷自控电机软起动器的原理、结构特点、主要性能及典型应用效果,说明无刷自控电机软起动器的优势和代替其它电机起动装置的必然性.

  16. Automatic control system of sewage treatment plant based on Siemens S7-300 PLC%基于西门子S7-300 PLC的生活污水处理厂自动控制系统

    Institute of Scientific and Technical Information of China (English)

    殷长江

    2012-01-01

    This article introduced the automatic control system in sewage treatment plant based on Siemens S7-300PLC, it realized the automatic control for all the structured sewage treatment plant equipment, and improve the equipment utilization and sewage treatment plant automation, to cause the water discharge get stability and reaches pollution standard.%介绍了基于西门子S7-300 PLC的生活污水处理厂的自动控制系统,对整个污水处理厂各构筑物设备实现自动控制,提高了设备的利用率和污水处理厂的自动化程度,使出水排放稳定到达排放标准.

  17. Estruturas automáticas para controle de água nos canais em lavoura de arroz irrigado Automatic structures for water control in channels on irrigated rice crops

    Directory of Open Access Journals (Sweden)

    Luís G. H. do Amaral

    2005-04-01

    Full Text Available O Rio Grande do Sul apresenta a maior área irrigada do Brasil, devido principalmente à lavoura de arroz irrigado por inundação. Um dos fatores que contribuem para reduzir a eficiência de irrigação nessas lavouras é o baixo grau de controle exercido pelas estruturas de distribuição de água. Os objetivos deste trabalho foram projetar e construir dois protótipos de estruturas hidráulicas para controle automático de vazão em canais de irrigação e comparar sua sensibilidade de controle de vazão com a sensibilidade de duas comportas fixas. Os protótipos construídos - uma comporta hidromecânica automática e um regulador automático de vazão - foram instalados à entrada de um canal secundário, juntamente com uma comporta-gaveta e uma comporta-vertedor, que são as estruturas mais utilizadas para controle de vazão no RS. Provocou-se uma variação de 0,20 m na altura da lâmina de água a montante, determinando-se a vazão em cada estrutura. A menor variação de vazão com a alteração da lâmina foi de 5,6%, obtida com o regulador automático de vazão, seguido da comporta-gaveta com 23,7%, da comporta hidromecânica com 30,5%, e da comporta vertedor com 1.177,2%.In Brazil, the State that presents the largest extension of irrigated lands is Rio Grande do Sul, mainly due to rice that grows under flooded conditions. One of the factors that contribute to decrease the efficiency of irrigation is the low degree of control obtained with the structures used on water distribution. The objectives of this work were to design and build two hydraulic structures for automatic flow control on irrigation channels, and to compare the flow control sensitivity of the built prototypes with two types of gates that are widely used in the rice fields at the Rio Grande do Sul State. The constructed prototypes - a hydro-mechanical gate and an automatic flow regulator - were installed at the entrance of a secondary channel, next to a sluice gate and

  18. Automatic Fiscal Stabilizers

    Directory of Open Access Journals (Sweden)

    Narcis Eduard Mitu

    2013-11-01

    Full Text Available Policies or institutions (built into an economic system that automatically tend to dampen economic cycle fluctuations in income, employment, etc., without direct government intervention. For example, in boom times, progressive income tax automatically reduces money supply as incomes and spendings rise. Similarly, in recessionary times, payment of unemployment benefits injects more money in the system and stimulates demand. Also called automatic stabilizers or built-in stabilizers.

  19. Automatic input rectification

    OpenAIRE

    Long, Fan; Ganesh, Vijay; Carbin, Michael James; Sidiroglou, Stelios; Rinard, Martin

    2012-01-01

    We present a novel technique, automatic input rectification, and a prototype implementation, SOAP. SOAP learns a set of constraints characterizing typical inputs that an application is highly likely to process correctly. When given an atypical input that does not satisfy these constraints, SOAP automatically rectifies the input (i.e., changes the input so that it satisfies the learned constraints). The goal is to automatically convert potentially dangerous inputs into typical inputs that the ...

  20. Boiler Feed Water/Makeup Water Automatic Control Design and Application%锅炉供水/补水自动控制设计及应用

    Institute of Scientific and Technical Information of China (English)

    万全福

    2014-01-01

    The improvement of the backward electrical facilities in the water supply system of industrial hot water boilers in the forest area can realize such functions as constant pressure automatic water feed / water makeup,automatic water discharge in case of overpressure and automatic alarms as well as a high automation degree and easy maintenance.%林区工业热水锅炉供水系统的电气设施落后,改进后使其具有了恒压自动供水/补水、超压自动泄水、自动报警等功能,并且自动化程度高,维护方便。

  1. Automatic differentiation bibliography

    Energy Technology Data Exchange (ETDEWEB)

    Corliss, G.F. (comp.)

    1992-07-01

    This is a bibliography of work related to automatic differentiation. Automatic differentiation is a technique for the fast, accurate propagation of derivative values using the chain rule. It is neither symbolic nor numeric. Automatic differentiation is a fundamental tool for scientific computation, with applications in optimization, nonlinear equations, nonlinear least squares approximation, stiff ordinary differential equation, partial differential equations, continuation methods, and sensitivity analysis. This report is an updated version of the bibliography which originally appeared in Automatic Differentiation of Algorithms: Theory, Implementation, and Application.

  2. B2016A型龙门刨床电控系统自动化改造%Automatic transformation of the electrical control system of B2016A planer

    Institute of Scientific and Technical Information of China (English)

    蒋士博; 陈竞雄; 刘捷; 方婷

    2012-01-01

    Using the control designing method of PLC technology, designs an outline of the electric control system for B2016A planer, rises the automatic control level of the planer, reduces the failure rate, rises the production efficiency.%用PLC技术中的顺序控制设计法,对B2016A型龙门刨床的电气控制系统进行了总体设计,提高了机床自动控制水平,降低了机床故障率,使生产效率得到了较大的提高.

  3. 自动标准压力发生器动态控制准确度分析%Dynamic Control Accuracy Analysis of Automatic Digital Pressure Controller

    Institute of Scientific and Technical Information of China (English)

    李海兵; 麻锐; 卓华; 陈武卿

    2014-01-01

    An additional uncertainty of pressure generators can be introduced to account for control precision. This additional precision is on-ly needed when the controls are in dynamic mode and the operator is using the front panel to display. Herein a calculation method of control preci-sion is displayed for PACE6000 serials pressure generators. It is assumed that a piston gauge is used as standard while a high-precision digital pressure gauge is applied as reference, and when 0.01-class pressure calibrator is used as standard, the uncertainty analysis of 0.05-class digital pressure gauge is shown, and the MPEV ( maximum permissible error value) of inlet-pressure transducer must be ±0.008%.%自动标准压力发生器(以下简称发生器)性能的一个重要指标是准确度。当发生器处于动态控制模式及使用面板显示时需要考虑附加控制准确度。本文通过对PACE6000系列的发生器进行比对实验,以活塞式压力计为标准器,高准确度数字压力计为参考对象,得出了其控制准确度,最后给出了以0.01级数字压力发生器为标准器、0.05级数字压力计示值误差的测量不确定度分析,其内置压力传感器的最大允许误差须为依0.008%。

  4. Design and Implementation of "Automatic Control Theory" Teaching Aid Software%《自动控制原理》教学辅助软件的设计与实现

    Institute of Scientific and Technical Information of China (English)

    朱钾; 邵桂荣

    2014-01-01

    随着我院向应用型、职业技能型的转型发展,传统的课堂教学模式不能适应新的培养方案及教学大纲的要求。将《自动控制原理》与MATLAB软件相结合,采用MATLAB/GUI设计了《自动控制原理》教学辅助软件,并以频域分析模块为例详细介绍了软件的实现过程。该软件操作简单、灵活,用于课堂教学,改善了理论教学效果,提高了学生的学习兴趣。%As the transformation development of applied and professional skilled university, the traditional classroom teaching mode can’ t adapt the requirements of the new training plan and syllabus. The "Automatic Control Theory" and MATLAB are combined, and"Automatic Control Theory" teaching aid software is designed with MATLAB/GUI. In the case of frequency domain analysis module, software implementation process is intro-duced in detail. The software is simple and flexible to operate. It is proved that the application of software to "Automatic Control Theory" can improve theoretical teaching effect and also inspired the students’ learning inter-est.

  5. Solar Powered Automatic Shrimp Feeding System

    Directory of Open Access Journals (Sweden)

    Dindo T. Ani

    2015-12-01

    Full Text Available - Automatic system has brought many revolutions in the existing technologies. One among the technologies, which has greater developments, is the solar powered automatic shrimp feeding system. For instance, the solar power which is a renewable energy can be an alternative solution to energy crisis and basically reducing man power by using it in an automatic manner. The researchers believe an automatic shrimp feeding system may help solve problems on manual feeding operations. The project study aimed to design and develop a solar powered automatic shrimp feeding system. It specifically sought to prepare the design specifications of the project, to determine the methods of fabrication and assembly, and to test the response time of the automatic shrimp feeding system. The researchers designed and developed an automatic system which utilizes a 10 hour timer to be set in intervals preferred by the user and will undergo a continuous process. The magnetic contactor acts as a switch connected to the 10 hour timer which controls the activation or termination of electrical loads and powered by means of a solar panel outputting electrical power, and a rechargeable battery in electrical communication with the solar panel for storing the power. By undergoing through series of testing, the components of the modified system were proven functional and were operating within the desired output. It was recommended that the timer to be used should be tested to avoid malfunction and achieve the fully automatic system and that the system may be improved to handle changes in scope of the project.

  6. 基于S7-200PLC的牲畜圈舍自动控制系统设计%An S7-200PLC-Based Design of Automatic Control System for the Livestock Houses

    Institute of Scientific and Technical Information of China (English)

    王志秦

    2016-01-01

    针对目前牲畜圈舍养殖环境卫生差、管理粗放、影响牲畜养殖效益的问题,对牲畜圈舍进行技术改造,设计了一套牲畜圈舍自动控制系统。将 S7-200PLC 作为系统控制的核心,通过温度传感器对环境温度进行采集和转换,采用MCGS组态软件设计控制界面,对温度信息进行实时监测,并实现牲畜圈舍粪便的自动清扫、温度自动调整、自动喂水排水等控制功能。通过实验室制作模型进行了模拟运行,此系统操作简便、可靠性高,能够实现对牲畜圈舍的自动化管理。%The author of this paper has designed a new automatic control system for the livestock houses in view of the current low breeding efficiency due to the poor breeding livestock house san-itation and slack management.S7-200PLC is the core of the control system and temperature sen-sors collects and converts the environment temperature.MCGS is applied to design the control in-terface.This system can perform real-time monitoring of temperature,automatic cleaning,auto-matic adj ustment o temperature,and automatic feeding and water drainage.Laboratory models were constructed and simulation showed that this system has the advantages of simple operation, high reliability and automatic management of livestock houses.

  7. Automatically-Programed Machine Tools

    Science.gov (United States)

    Purves, L.; Clerman, N.

    1985-01-01

    Software produces cutter location files for numerically-controlled machine tools. APT, acronym for Automatically Programed Tools, is among most widely used software systems for computerized machine tools. APT developed for explicit purpose of providing effective software system for programing NC machine tools. APT system includes specification of APT programing language and language processor, which executes APT statements and generates NC machine-tool motions specified by APT statements.

  8. 关于污水处理厂自动控制系统设计分析%Design and analysis of automatic control system for wastewater treatment plant

    Institute of Scientific and Technical Information of China (English)

    何王金

    2015-01-01

    With the rapid development of China's market economy, the environmental problem has become a serious problem,and sewage treatment is the problem that people need to be solved..At present, China has established a lot of sewage treatment plant, the automatic control system is the key technology of sewage treatment,to realize the automatic control of sewage treatment plant,and the process parameters,data collection,analysis and management, to ensure that the effluent standard,improve production efficiency, reduce the production cost. This paper mainly introduces the sewage treatment plant automatic control system features and functions, and introduces the principle of the overall design of the automatic control system and to various parts of the design analysis,hoping to ensure the design of automatic control system of sewage treatment plant is more reasonable.%随着我国市场经济的快速发展,环境问题已成为了一个严重的问题,其中污水处理问题就是人们需要亟待解决的问题。目前,我国已经建立了很多污水处理厂,其中自动控制系统是污水处理的关键技术,实现了污水处理厂的自动化控制,并且对工艺参数、数据进行采集、分析和管理,保证了出水的达标,提高了生产效率,降低了生产成本。本文主要介绍了污水处理厂自动控制系统的特点和功能,并介绍了自动控制系统的总体设计原则以及对各部分设计进行分析等,希望能保证污水处理厂的自动控制系统设计更加合理。

  9. Feasibility of low-concentration iodinated contrast medium with lower-tube-voltage dual-source CT aortography using iterative reconstruction: comparison with automatic exposure control CT aortography.

    Science.gov (United States)

    Shin, Hee Jeong; Kim, Song Soo; Lee, Jae-Hwan; Park, Jae-Hyeong; Jeong, Jin-Ok; Jin, Seon Ah; Shin, Byung Seok; Shin, Kyung-Sook; Ahn, Moonsang

    2016-06-01

    To evaluate the feasibility of low-concentration contrast medium (CM) for vascular enhancement, image quality, and radiation dose on computed tomography aortography (CTA) using a combined low-tube-voltage and iterative reconstruction (IR) technique. Ninety subjects underwent dual-source CT (DSCT) operating in dual-source, high-pitch mode. DSCT scans were performed using both high-concentration CM (Group A, n = 50; Iomeprol 400) and low-concentration CM (Group B, n = 40; Iodixanol 270). Group A was scanned using a reference tube potential of 120 kVp and 120 reference mAs under automatic exposure control with IR. Group B was scanned using low-tube-voltage (80 or 100 kVp if body mass index ≥25 kg/m(2)) at a fixed current of 150 mAs, along with IR. Images of the two groups were compared regarding attenuation, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), iodine load, and radiation dose in various locations of the CTA. In comparison between Group A and Group B, the average mean attenuation (454.73 ± 86.66 vs. 515.96 ± 101.55 HU), SNR (25.28 ± 4.34 vs. 31.29 ± 4.58), and CNR (21.83 ± 4.20 vs. 27.55 ± 4.81) on CTA in Group B showed significantly greater values and significantly lower image noise values (18.76 ± 2.19 vs. 17.48 ± 3.34) than those in Group A (all Ps < 0.05). Homogeneous contrast enhancement from the ascending thoracic aorta to the infrarenal abdominal aorta was significantly superior in Group B (P < 0.05). Low-concentration CM and a low-tube-voltage combination technique using IR is a feasible method, showing sufficient contrast enhancement and image quality. PMID:26621755

  10. Research on automatic landing control for high span-chord ratio UAV in crosswind%大展弦比无人机抗侧风着陆控制研究

    Institute of Scientific and Technical Information of China (English)

    宋辉; 陈欣; 李春涛

    2011-01-01

    As one of the most complex phases in whole flight process, a high span-chord UAV is extremely sensitive to crosswind because of its low airspeed during landing. Through analyzing the influence of crosswind on flight performance of the sample UAV during landing phase, this essay puts forward some methods to enhance the control performance during automatic landing by optimizing the landing trajectory, controlling the airspeed and improving the longitudinal and lateral control strategy. Finally, simulation results show that the landing trajectory is reasonable , the automatic landing control strategy is valid and the control law is correct, which satisfy the demands of the automatic landing control under the crosswind conditions.%大展弦比无人机进场着陆过程中速度较低,对侧风十分敏感,是飞行过程中控制最复杂的阶段之一.通过分析侧风条件对样例无人机着陆过程的影响,提出了通过优化设计着陆轨迹线、控制空速以及完善纵横向控制策略的方法来改善侧风条件下大展弦比无人机自动着陆的控制品质.仿真结果表明,所设计的自动着陆轨迹线合理,控制策略完备,控制律品质良好,满足样例无人机在侧风条件下自动着陆控制的设计要求.

  11. Research on automatic table tennis ball machine design and control system%自动乒乓球发球机设计及其控制系统的探究

    Institute of Scientific and Technical Information of China (English)

    李新明

    2014-01-01

    In China table tennis is regarded as "the country ball",it is a sport for all ages,in order to make the learners to practice table tennis,table tennistechnology according to the characteristic,we invented an automatic table tennis ball machine,the automatic table tennis ball machine design and the control system is studied.%在我国乒乓球被视为“国球”,它也是一项老少皆宜的健身运动项目,为了让学习者更好地练习乒乓球,根据乒乓球发球技术特点,我们发明了一种自动乒乓球发球机,本文针对自动乒乓球发球机设计及其控制系统进行了研究探索。

  12. 钢管超声波自动探伤控制装置的研制与应用%Development and Application of Ultrasonic Automatic Flaw Detection Control Device for Steel Pipe

    Institute of Scientific and Technical Information of China (English)

    常少文; 杨彤

    2012-01-01

    In this article, it analyzed structure and implement proposal of ultrasonic automatic flaw detection control device, as well as its application in steel pipe inspection. This device utilizes unitization and modular structure design to ensure stable extraction of control signal and echo signal, accuracy and high efficiency of continuous automatic flaw detection. The application results showed that this device possesses some advantages, such as high automation degree, running fast, good compatibility, versatility, and so on. It improved accuracy and reliability of ultrasonic automatic flaw detection, achieved misinformation rate is less than 2%, missing rate is zero, which meets production requirements of ultrasonic automatic detection for steel pipe.%分析了超声波自动探伤控制装置的组成结构、实施方案以及在钢管检测中的应用情况.该超声波自动探伤控制装置采用单元化和模块化结构设计,保证了控制信号、回波信号的稳定提取以及连续自动化探伤检测的准确性和高效率.实际使用结果表明,该装置具有自动化程度高,运行节拍快,兼容性及通用性良好等特点.该装置的使用提高了超声波自动检测的准确性和可靠性,做到了误判率小于2%,漏检率为0,满足了钢管超声波自动检测的生产要求.

  13. Automatic Error Recovery in Robot Assembly Operations Using Reverse Execution

    DEFF Research Database (Denmark)

    Laursen, Johan Sund; Schultz, Ulrik Pagh; Ellekilde, Lars-Peter

    2015-01-01

    , in particular for small-batch productions. As an alternative, we propose a system for automatically handling certain classes of errors instead of preventing them. Specifically, we show that many operations can be automatically reversed. Errors can be handled through automatic reverse execution of the control...... program to a safe point, from which forward execution can be resumed. This paper describes the principles behind automatic reversal of robotic assembly operations, and experimentally demonstrates the use of a domain-specific language that supports automatic error handling through reverse execution. Our...... contribution represents the first experimental demonstration of reversible computing principles applied to industrial robotics....

  14. Application Analysis of Artificial Intelligence Technology in Automatic Control System%人工智能技术在自动化控制系统中的应用分析

    Institute of Scientific and Technical Information of China (English)

    张淑英

    2014-01-01

    以FFS包装机控制系统的人工智能技术的应用为例,结合人工智能技术应用的诸多优势,分析了人工智能技术在自动化控制系统中的应用。人工智能技术有利于自动化控制系统的故障诊断及隐患的精确判别,极大地提升了自动化控制设备的精密度及操作效率,显著地节省了各类资源消耗,该技术在自动化控制领域内值得进一步推广。%Application of artificial intelligence technology in FFS packaging machine control system in this paper as an example, combining the advantages of the application of artificial intelligence technology, analyzes the artificial intelligence technology application in the automatic control system. Artificial intelligence technology is benefit for automation control system fault diagnosis and potential accurate identification, it greatly improved the precision and efficiency of operation automation control equipment, significant saving the consumption of resources, the technology is worthy of further promotion in the automatic control field.

  15. Stopper Control Automatically Pull Steel Control System Application in R9m Continuous Casting Machine%塞棒控制自动拉钢控制系统在R9米连铸机的应用

    Institute of Scientific and Technical Information of China (English)

    王敏

    2014-01-01

    石横特钢二炼钢车间现有四机四流 R9米连铸机一座,优钢的开发和生产全靠塞棒控制系统提供稳定的液面及恒拉速,从而保证钢水形成钢坯的质量,对提高铸坯质量起到一定的作用,在目前工业自动控制系统中,可编程逻辑微处理器(SC3000- PID)、探测器(HN- DET- D51/290- M2)、驱动器(SCDK- S5)作为常用的成熟现场控制设备,上位机作为数据采集系统已经得到广泛使用。通过检测液面,传输到微处理器进行换算, PLC模块控制驱动器直接控制电动缸微动作,实现闭环控制,从而得到高精度的钢水液面。%There is four machine four flow meters caster R9 in Stone Cross Steel no . 2 steelmaking workshop . The development and production of superior steel depend on steady liquid level control sys-tem and constant speed provided by stopper rod control system , so as to guarantee the quality of formed steel billet and play a role to im-prove casting quality . In current industrial automatic control system , programmable logic microprocessor (SC3000 - PID), detector (HN -DET - D51/290 - M2), driver (SCDK - S5) are commonly used as mature field control equipment , and PC as the data acquisition system has been widely used . By detecting liquid level and transmitting to the microprocessor for conversion , PLC module control drive directly con-trols electric cylinder micro motion , achieves closed-loop control , so as to get high precision of liquid steel surface .

  16. Automatic Payroll Deposit System.

    Science.gov (United States)

    Davidson, D. B.

    1979-01-01

    The Automatic Payroll Deposit System in Yakima, Washington's Public School District No. 7, directly transmits each employee's salary amount for each pay period to a bank or other financial institution. (Author/MLF)

  17. Application of remote-control automatic offtake system in Gantang Compressor Station of West-to-East Gas Pipeline%远控自动分输系统在西气东输甘塘站的应用

    Institute of Scientific and Technical Information of China (English)

    梁怿; 韩建强; 王磊

    2013-01-01

    针对西气东输日益增多的分输站场与低下的调度效率之间的矛盾,结合压缩机组已实现远程控制的现状,根据西气东输站场自动化控制系统的构架,对现有系统程序进行编辑与修改,添加了分输系统远程控制权限,优化了PID控制,编写了远程控制界面,提出了在甘塘分输站场进行远控自动分输改造方案.通过对PLC控制系统、RCI配置文件和中心控制系统的优化及2个月的试运行,实现了西气东输分输用户的远控自动分输,提高了生产效率,优化了人力资源配置.%For the contradiction between a growing number of offtake stations and low dispatching efficiency in the West-to-East Pipeline and in accordance with remote control status of compressor units, existing system programs are edited and modified on the basis of automation control system architecture of gas compressor stations in the West-to-East Gas Pipeline to add remote control authority for the offtake system, optimize PID control and formulate a remote control interface, thus proposing a offtake program for remote control automatic offtake of Gantang distribution station. Through optimization of PLC control system, RCI configuration files and central control system and test running for 2 months, remote control automatic offtake of offtake users in the West-to-East Gas Pipeline to improve production efficiency and optimize allocation of human resources.

  18. Design of Automatic Control System of Handling Machinery Based on Siemens S7-300 PLC%基于西门子S7-300PLC装卸机械自控系统设计

    Institute of Scientific and Technical Information of China (English)

    王林; 张宗喜; 牛秦洲

    2012-01-01

    Focuses on the mechanical loading and unloading control system structure, the control requirements of the system during operation, and how to achieve automatic operation of the machine function, using S7-300 PLC program features modular design, designing manual control subroutine and automatic control subroutine and tissue procedures, which greatly improving the efficiency and production safety.%主要介绍了装卸机械控制系统的构成、系统在运行过程中的控制要求、以及如何实现机械自动操作的功能,利用S7-300PLC的功能模块化程序设计思想,设计出手动控制逻辑功能和自动控制逻辑功能及组织块程序,大大提高了工作效率和生产安全性.

  19. Study on control algorithm for Automatic Train Operation based on neural network%基于神经网络的列车自动驾驶控制算法研究

    Institute of Scientific and Technical Information of China (English)

    费洋; 吴永城

    2014-01-01

    对列车自动驾驶系统的速度控制过程进行了分析,针对传统PID算法缺乏自适应能力的缺点,在传统神经网络算法的基础之上对神经元的学习算法作出改进,设计出了基于RBF网络辨识的单神经元自适应PID控制器,仿真结果表明该控制器能够满足列车自动驾驶系统速度控制要求。%The speed control process for Automatic Train Operation is analyzed, and as the traditional PID algorithm lacks adaptability, a single neuron adaptive PID controler based on RBF neural network is designed. The result of simulation shows that the controler can meet the speed control requirements for Automatic Train Operation.

  20. 基于PLC的乒乓球自动分装控制系统的设计%Automatic packing control system design based on the PLC table tennis

    Institute of Scientific and Technical Information of China (English)

    岳晓礼

    2012-01-01

    本文运用PLC针对乒乓球在分装线上的三种不同数量的包装规格,根据控制过程中的若干步骤,采用顺序控制法设计出乒乓球自动分装控制系统程序,很好地解决了工业生产控制领域的方便、经济、灵活等问题。%In this paper, PLC packing line,the nnmber of three different packaging specifications for the table tennis sequence control method according to the number of steps in the control process,the design table tennis automatic packing process control system,a good solutionindustrial production control areas of convenient,economical,flexible,and other issues.

  1. Developing free software for automatic registration for the quality control of IMRT with movies; Desarrollo de un software gratuito para el registro automatico durante el control de calidad de la IMRT con peliculas

    Energy Technology Data Exchange (ETDEWEB)

    Moral, F. del; Meilan, E.; Pereira, L.; Salvador, F.; Munoz, V.; Salgado, M.

    2011-07-01

    In this work, as the commissioner of the e-JMRT, a Monte Carlo calculation network for IMRT planning, has developed software for the automatic recording of the image of the film with the results of the planning system.

  2. Design of Automatic Control System of Three-phase Voltage Regulating Based on Single-chip Microcomputer%基于单片机的三相调压自动控制系统的设计

    Institute of Scientific and Technical Information of China (English)

    邢月华; 付磊; 薛章华

    2012-01-01

    针对传统的交流调压器难以满足实时、精确调压和稳压的问题,设计了一种基于单片机的三相调压自动控制系统,详细介绍了系统的硬件电路和软件的实现.该系统以AT89C51单片机为控制核心,可实时监测电压信号的变化,实现在设定电压下的手动、自动调压功能.该系统还可以实现0.01 V以上电压采集精度、0~400 V之间升压、降压及稳压的自动控制功能.试验结果表明,该系统具有电路简单,工作可靠性强和自动化水平高等优点.%Far problems that traditional AC voltage regulator is difficult to meet with real-time, precision regulator and voltage stabilization, an automatic control system of three-phase voltage regulating based on single-chip microcomputer was designed, realization of hardware circuit and software of the system were introduced in details. The system takes AT89C51 single-chip microcomputer as control core, can real-timely monitor change of voltage signal and achieve manual, automatic voltage regulating function according to set voltage. It also can achieve 0. 01 V voltage collection precision, automatic control functions of 0-400 V boost, buck and stabilization of voltage. The experiment results showed that the system has advatages such as simple circuit, strong work reliability and high automation level.

  3. Automatic Pilot For Flight-Test Maneuvers

    Science.gov (United States)

    Duke, Eugene L.; Jones, Frank P.; Roncoli, Ralph B.

    1992-01-01

    Autopilot replaces pilot during automatic maneuvers. Pilot, based on ground, flies aircraft to required altitude, then turns control over to autopilot. Increases quality of maneuvers significantly beyond that attainable through remote manual control by pilot on ground. Also increases quality of maneuvers because it performs maneuvers faster than pilot could and because it does not have to repeat poorly executed maneuvers.

  4. 基于EM78P510NK的全自动咖啡机控制系统的设计%Design of Automatic Coffee Machine Control System Based on the EM78P510NK

    Institute of Scientific and Technical Information of China (English)

    邵雯

    2013-01-01

    This article introduced automatic coffee machine control system 's design.Its core is MCU based on EM78P510NK, it can control the position of piston and seal gland, temperature, water flow, coarseness of coffee reliably.It can give an alarm when hydropenia and lack coffee.The automatic coffee machine control system has advantages of reliable operation, simple structure, easy to debug and expansion.It is used in business, catering industry, office and family, etc.%介绍一种全自动咖啡机控制系统的设计,它以EM78P510NK处理器为核心,对活塞位置、密封套位置、温度、水流量、咖啡粗细度等进行可靠控制,具有缺水、缺豆报警功能.该系统工作可靠、结构简单、易于调试和扩展,适合于商业、餐饮业、办公室和家庭.

  5. Research on the application of the automatic loading control system of S7-200 based on PLC%基于S7-200 PLC的原油自动装车控制的研究应用

    Institute of Scientific and Technical Information of China (English)

    马晓军; 陆艳斌

    2014-01-01

    A focus pul oil oilifeld as an example,a detailed description of the structure and control of automatic loading control system theory based on the PLC. According to the actual conditions in remote areas,the use of mobile 3G wireless network and automatic loading control system for effective integration,to a certain extent,to solve the personnel employment tension. Reduced employee labor mild,improve labor productivity.%以某油田集中拉油点为例,详细描述了基于PLC的自动装车控制系统的构成和控制原理。根据边远地区实际情况,有效的利用移动3G无线网络与自动装车控制系统进行整合,在一定程度上解决了人员的用工紧张程度。降低了员工的劳动轻度,提高了劳动生产率。

  6. 基于PROFIBUS现场总线的大袋自动包装机控制系统设计%Design of the Control System of Automatic Sack-Packaging Machine Based on PROFIBUS

    Institute of Scientific and Technical Information of China (English)

    王嵩; 张秋菊; 陈中杰; 左文娟

    2015-01-01

    为改善现有大袋包装机控制系出现的一些问题,针对某新型大袋自动包装机,设计了基于PROFIBUS-DP现场总线的控制系统,详细介绍了控制系统的硬件结构和软件实现流程,该控制系统具有很强的网络通信能力,为实现大袋自动包装机的智能化和远程监控提供了便利。%In order to solve the problem of the control system of the sack packaging machine, the control system based on Fieldbus of PROFIBUS-DP was designed for some new automatic sack packaging machine. The hardware of the control system and the process of software was elaborately introduced, it has a very strong network communication ability, and it makes convenient the intelligentisation of the automatic sack packaging machine and long-distance monitoring.

  7. Research of the Optimal Automatic Generation Control Strategy of Interconnected Power Grid Based on CPS Standard%基于CPS标准的互联电网最优自动发电控制策略研究

    Institute of Scientific and Technical Information of China (English)

    田启东; 翁毅选

    2015-01-01

    研究了考虑CPS的互联电网自动发电控制问题,提出了基于CPS和最优动态闭环控制的自动发电控制策略,在区域间互联电网中建立自动发电控制状态空间数学模型,采用了外点罚函数法进行目标函数的求解,并计及了CPS的新动态性能指标.与传统A标准下的PI控制策略相比,文中提出的方法考虑了区域控制偏差对系统频率恢复的贡献,明显地提高了CPS考核指标,降低了AGC机组的调节次数,减少了发电成本.同时,结合了最优化控制的良好的内部感知能力和动态适应性的优点.通过仿真分析,并与传统的控制策略相比较,结果表明文中提出的控制策略具有更优异的动态特性和更好的调节性能.%This paper studies the automatic generation control of the interconnected power grid considering CPS,and puts forward an automatic generation control strategy based on the CPS standard and optimal dynamic closed-loop control. It establishes the state space mathematic model of the automatic generation control of a two-region power grid,and introduces a new dynamic performance index which takes CPS into account and uses the outer point penalty function method to solve the objective function. Compared with the traditional PI control strategy based on A standard,the proposed method in the paper considers the contribution of ACE for frequency recovery,and obviously improves the CPS Assessment index,and reduces the number of regulation orders of AGC units and the cost of power generation. It combines the good internal perception and dynamic adaptability advantages of optimal control. Through simulation analysis,compared with conventional control stra-tegy,the proposed control strategy has more excellent dynamic characteristics and better regulation performance.

  8. 太阳能抽水泵的自动追光控制系统研究%The Automatic Tracking Control System about Pumps by Solar Energy

    Institute of Scientific and Technical Information of China (English)

    蔺金元; 剡文杰

    2012-01-01

    在西部偏远的农村,阳光充足,太阳能要比电能更容易获得,农业用水可以采用太阳能抽水泵。介绍了一种自动追光控制系统,可以用它来辅助抽水泵的太阳能供电系统,控制步进电机去带动太阳能电池板自动旋转,使电池板能够保持在太阳能转换效率最高的位置,能够使太阳能抽水泵更加充分利用太阳能资源。%In the western countryside,solar energy is sufficient,solar energy is obtained more easily than power.Agricultural water can use solar water pumps.An automatic tracking system which can automatically tracksolar is introduced in this paper.The system is used for pumps that have solar power supply systems,then the battery plate which is driven by the stepper motor can rotate according to the value of absorption power.Thus,the battery plate can be always in the position which is available to absorb maximum power.The solar energy water pump can use solar energy more fully by this system.

  9. 乳品冷却工艺中自动控制氨用满液式蒸发器的应用%The Application of Automatic Control Flooded Evaporator of Ammonia in Dairy Cooling Technology

    Institute of Scientific and Technical Information of China (English)

    徐锡春; 杨寿发; 蔡馨馨

    2011-01-01

    According to the need of dairy fast cooling and the working principle of water cooling system in dairy production process, we used the advanced electronic measurement technology and cortrol valves to auto-control the flooded evaporator of ammonia. The temperature of cold water could be controlled accurately by the automatic control flooded evaporator and ammonia system could work safely and dependably.%根据乳品生产过程中乳品快速冷却的需要和乳品冷水冷却系统的工作原理,在乳品冷却工艺中应用先进的电子测控技术和控制阀件自动控制氨制冷系统满液式壳管蒸发器,可快速精确地调节冷水温度,使氨系统安全可靠地运行.

  10. 电弧炉佘热回收锅炉的自动控制系统%Automatic Control System of the Waste Heat Recovery Boiler for the EAF

    Institute of Scientific and Technical Information of China (English)

    宋水根; 曾玉清; 刘涛; 曾辉

    2011-01-01

    主要介绍了电弧炉余热回收锅炉的自动控制系统.在该系统中采用了西门子S7-300 PLC,实现对中低压汽包水位PID调节及设备的联锁控制,并对余热回收产生蒸汽全过程进行动态管理和控制.%This paper mainly describes the development of automatic control system of electric furnace Waste heat recovery boiler. PID control,equipments chain starting and the water constant level supply are used in this system. The whole process of dynamic management and control of Steam generation from heat recovery boiler are realized by Siemens S7-300 PLC.

  11. Automatic Control Technology of Process Equipment Based on Process Data Driven%基于工艺数据驱动的工艺装备自动控制技术

    Institute of Scientific and Technical Information of China (English)

    柳敏

    2015-01-01

    With the increasingly fierce market competition, production-oriented enterprises to occupy market advantage have to improve product quality and shorten the manufacturing cycle, and the movement precision of industrial equipment and important influence on the degree of automation, so has been widely followed, for promoting the manufacture process of complex product production effect, need to process on the basis of data driven system study of its process equipment automatic control system, through the analysis of process data provided by the system, building equipment automatic control technology for object information model of industry, formed on the basis of the process equipment automatic control technology to control the management platform, to guarantee the production quality of the products at the same time, promote the development of the automation, digital, this paper based on the technology of data driven process equipment automatic control system of research, form the relevant process information model and process equipment automatic control technology, combined with personal experience for application authentication, in an effort to promote manufacturing production capacity.%随着市场竞争的日渐激烈,生产型企业为了占具市场优势,必须在提升产品质量的同时缩短制造周期,而工艺装备的运动精度和自动化程度对此产生直接影响,所以一直受到广泛关注.为提升复杂产品制造过程的生产效果,需要在工艺数据驱动的基础上,对其工艺装备自动控制体系进行系统研究,通过对提供的工艺数据进行系统分析,构建以工装自动控制工艺为对象的产业信息模型,形成以工艺装备自动控制技术为基础的控制管理平台,在保证产品生产质量的同时,推动其自动化、数字化发展.本文通过对基于工艺数据驱动的工艺装备自动控制体系的研究,并结合个人经验,对形成的相关工艺信息模型和工艺装备自

  12. Comparative Study of Automatic and Manual Exposal Controlled Radiographs of 1 000 Cases Shot by IMIX DR%IMIX DR自动、手动曝光控制胸片1000例对比研究

    Institute of Scientific and Technical Information of China (English)

    郑放超; 丁成怀; 李超; 明锐奇; 窦红梅

    2011-01-01

    Objective To discuss a method in order to reduce exposure, improve the X-ray image quality, reduce machine depletion, and extend the service life of the machine. Methods 500 pieces of radiographs were shot using automatic exposure control mode. The exposure of chest films with the same body thick was found out, using 50% of which, 500 pieces of radiographs were shot using manual exposure control mode for the comparison. Results The exposure less than or equal to that of the automatic exposure control mode was feasible for the chest film shooting. Conclusion There is no obvious difference in the image quality of chest radiographs shot by the two control modes. Manual exposure control mode in contrast, is better than automatic exposure control mode in increasing the contrast and reducing exercise-induced fuzzy of the radiograph, which can improve the image quality of the chest film. In this way, X-ray irradiation of clients can be reduced greatly. machine depletion can be reduced. and also the use efficiency of DR can be improved.[Chinese Medical Equipment Journal. 2011 , 32 ( 5) : 105-106 . 110]%目的:探讨如何减少X线曝光量,提高胸片影像质量,减少机器损耗并延长使用寿命.方法:用自动曝光控制方式拍摄胸片(以下简称自控胸片)500例,找出相同体厚胸片的曝光量,用其约1/2的曝光量在手动曝光控制方式下拍摄胸片(以下简称手控胸片)500例,将其进行对比.结果:用≤自动曝光控制方式1/2的曝光量拍摄胸片是可行的.结论:2种控制方式拍摄的胸片影像质量没有明显的差异,手控胸片在提高反差、减少运动性模糊方面优于自控胸片,能部分提高胸片的影像质量;这样可使受检者X线照射量大幅度降低;同时也减少了机器损耗、提高了DR的使用效率.

  13. From automatic control of vessels designed to operate in offshore conditions to automatic control of a large barge convoy in a river/channel: lessons learned; Do controle automatico de embarcacoes projetadas para condicoes operacionais de offshore para o controle automatico de um grande comboio de barcacas em um rio/canal: licoes aprendidas

    Energy Technology Data Exchange (ETDEWEB)

    Pontes, Anselmo Carvalho [Symmetry Ltda., Rio de Janeiro, RJ (Brazil); Santos, Edson Mesquita do [Marinha do Brasil, Rio de Janeiro, RJ (Brazil)

    2008-07-01

    The waterway transportation sector, despite its problems and bottlenecks, is continually seeking alternatives to improve its operations. With goals of increased efficiency, safety and cost reduction, the sector is modernizing and acquiring new technology. The Dynamic Position control system for a large barge convoy is one of the new technology highlights. This innovation may make development in the Brazilian waterway transportation sector feasible by permitting navigational safety and greater flexibility in transport and distribution not only for mined products but for petroleum and its derivatives. This paper presents the development process of The Dynamic Position control system for a large barge convoy in the Parana-Paraguay River, for Rio Tinto Mining Company. The hydrodynamics effects in a river are quite different than those of the traditional offshore environment. The degree of difficulty involved in solving this problem is highly dependent on a ship's characteristics, which can be analyzed in function of their hydrodynamic coefficients. Model tests in towing tanks were made to adjust the hydrodynamic coefficients and characteristics of the thrusters. The choice of the 'backstepping' control law and observer (state estimator) presented in this paper is a result of these particular conditions. The authors point out the advantage of using this technique, since all the properties of the coefficients of the hull, propeller(s) and thruster(s) have already been tested and tuned and are able to make a reliable set-up that optimizes navigation in restricted waterways. (author)

  14. The Monitoring System for the Important Technics Signals of Automatic Control System%控制系统重要工艺信号报警次数监测系统

    Institute of Scientific and Technical Information of China (English)

    史翔

    2011-01-01

    主要描述了从DCS自动控制系统提取和发布重要工艺信号报警次数。控制系统重要工艺信号报警次数监测系统不仅能够对可能发生的事故进行预警,降低事故发生的概率,也为生产管理、设备检修提供了科学依据,更为企业管理提供了科学的、量化的管理手段,在煤炭和煤化工行业有着很广泛的应用前景。%The paper mainly describes how to collect and publish the alarm data of important technics signals from DCS automatic control system. The monitoring system of the important technics signals in automatic control system is not only able to warn the accidents, cut down the rate of accidents, but offer the basis for production management and equipment repairing. It also provides the scientific and quantified management means. Now it is widely applied in coal and chemical industry.

  15. On analysis of key technique for automatic control over heating and domestic hot water system%供热及生活热水系统自动控制关键技术分析

    Institute of Scientific and Technical Information of China (English)

    王旭东

    2012-01-01

    The paper researches the application of the automatic control and the sensing technology in the hot water system of central air-condi- tioners and domestic hot water system in mansions, solves some controlling problems, such as steam heat source temperature of central air-condi- tioner, the pressure adjustment, and the heat storage of electrical boiler for domestic hot water, and realizes the automatic operation of the steam heat source adjustment and the heat storage system of the electrical boiler for domestic hot water.%研究了自动控制技术、传感技术在大厦中央空调热水系统以及生活热水系统中的应用,解决了中央空调热水系统蒸汽热源温度、压力的调节问题以及生活热水电锅炉蓄热的控制问题,实现了蒸汽热源调节的自动化运行以及生活热水电锅炉蓄热系统的自动化运行。

  16. Automatic text summarization

    CERN Document Server

    Torres Moreno, Juan Manuel

    2014-01-01

    This new textbook examines the motivations and the different algorithms for automatic document summarization (ADS). We performed a recent state of the art. The book shows the main problems of ADS, difficulties and the solutions provided by the community. It presents recent advances in ADS, as well as current applications and trends. The approaches are statistical, linguistic and symbolic. Several exemples are included in order to clarify the theoretical concepts.  The books currently available in the area of Automatic Document Summarization are not recent. Powerful algorithms have been develop

  17. Automatic utilities auditing

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Colin Boughton [Energy Metering Technology (United Kingdom)

    2000-08-01

    At present, energy audits represent only snapshot situations of the flow of energy. The normal pattern of energy audits as seen through the eyes of an experienced energy auditor is described. A brief history of energy auditing is given. It is claimed that the future of energy auditing lies in automatic meter reading with expert data analysis providing continuous automatic auditing thereby reducing the skill element. Ultimately, it will be feasible to carry out auditing at intervals of say 30 minutes rather than five years.

  18. 基于PLC数控螺旋锥齿轮研齿加工的自动控制%Automatic Control of CNC Spiral Bevel Gear Machining Based on PLC

    Institute of Scientific and Technical Information of China (English)

    肖春芳

    2013-01-01

    Based on the S7-300 PLC,combined with the gas-liquid booster drive control technology,the automatic control of the logarithmic control wheel gear lapping machine is realized.The principle of using gas-liquid booster clamping drive system in CNC spiral bevel gear lapping machine control is analyzed.on this CNC spiral bevel gear lapping machine Grinding tooth loop automatic control with PLC (S7-300),provides the main principle of hardware and software of ladder diagram.The experiment results show that the program has the advantages of compact structure,high efficiency,and able to achieve good design requirements.%基于S7-300 PLC,结合气液增压传动控制技术,实现了对数控轮研齿机研齿加工的自动控制.分析了采用气液增压夹紧传动系统实现数控螺旋锥齿轮研齿机研齿加工控制的原理.研究了采用PLC(S7-300)实现数控螺旋锥齿轮研齿机研齿的自动控制,提供了主要的硬件原理图和软件梯形图.实验结果证明:程序结构紧凑、运行效率高,且可以很好的实现设计要求.

  19. On designing of an Automatic Controlling Circuit for Stable Laser Frequency based on AD Sampling%基于AD采样的激光稳频自动控制电路的设计

    Institute of Scientific and Technical Information of China (English)

    张珍

    2012-01-01

    AD Sampling and its data transmission is the crucial part for converting analog signals in sensors to digital signals and transmitting the information signals to other equipment,and the detecting,displaying and controlling of parameters can be realized through computer controlling.With the rapid development of IT technology,the application of AD Sampling and automatic computer controlling through digital transmission have been widely used.This essay puts forward the designing of an automatic controlling circuit for stable laser frequency based on AD sampling,so as to effectively control the emission wavelength of laser in a long run.%AD(Analog-to-Digital)采样及其数据传输是从传感器和其它待测设备等模拟量转换为数字量并自动采集信息输送给其他设备的不可缺少的部分,并且通过计算机控制,可实现对参量的实时检测、显示与控制。随着信息技术的飞速发展,采用AD采样并通过数字传输的计算机自动控制方面的应用越来越广泛,如激光雷达的发射激光波长自动检测。本文给出了一种基于AD采样的激光稳频自动控制电路的设计,可有效实现对激光器发射波长的长期稳定的自动控制。

  20. 一种全自动化肥包装码垛机码垛控制单元的设计%Design of Palletizing Control Unit for Full Automatic Fertilizer Packaging Stacker

    Institute of Scientific and Technical Information of China (English)

    董晶; 姜永增; 郭艳宏

    2014-01-01

    This paper presents a design method simply , efficiently and safely for the palletizing system .It uses a variety of detection elements , is based PLC control technology , inverter technology , adopts state-of-the-art touch screen tech-nology .The design fully meets the control requirements of automatic packaging palletizing system for the palletizing con-trol system .The article briefly introduces machine features automatic packaging palletizing system , details the composi-tion of the structure of the palletizing control system , control flow .The design of the system has many advantages , in-cludes excellent crew drive performance , fast response , high operating efficiency , It achieves the purpose of energy con-servation , energy efficiency .%提出了一种机构简单、高效安全的码垛控制单元的设计方法,采用多种检测元件,基于 PLC 控制技术、变频器技术等多种优良控制技术,并采用了先进的触摸屏技术,完全满足了全自动包装码垛系统对码垛控制系统的控制要求。同时,简单介绍了全自动包装码垛系统的整机特点,详述了码垛控制系统的组成结构、控制流程和界面设计。本设计系统机组传动性能优良、响应速度快、操作效率提高,并达到了节能、降耗、增效的目的。

  1. Design of ADRC for Automatic Position Control Stopping System of Rolling Mill%轧机自动位置控制停车系统ADRC控制器设计

    Institute of Scientific and Technical Information of China (English)

    张瑞成; 陈陆曦

    2015-01-01

    Based on analyzing the damping force ,the elastic force and the roll eccentricity force between the roll and the strip ,a non-linear model of the automatic position control (APC) stopping system of rolling mill is derived .The dynamic analysis shows the APC stopping system has the chaotic characteristics .Based on the characteristics of the APC stopping system ,such as nonlinear and varia-ble parameters ,a two-order active disturbance rejection controller (ADRC) for the automatic position control stopping system is de-signed ,and the simulation is done within uncertainty environment .The simulation results show that the controller has ideal robust-ness to the system chaos and the large load disturbance ,and rapid and smooth control process and high steady precise performances can be implemented .%在考虑轧辊与轧件间的阻尼力、弹性力和轧辊偏心力的基础上 ,建立了一个轧机自动位置控制(A PC ) 停车系统的非线性模型 ,对其动力学特性分析表明该系统具有混沌特性.针对此系统具有非线性、变参数的特点 ,采用自抗扰控制 (ADRC ) 方法设计二阶 ADRC控制器 ,并在不确定性环境下进行仿真研究.结果表明 :ADRC控制器对于系统出现的混沌和大负载干扰具有理想的鲁棒能力 ,其控制过程快速、平滑 ,稳态精度高.

  2. Practical automatic Arabic license plate recognition system

    Science.gov (United States)

    Mohammad, Khader; Agaian, Sos; Saleh, Hani

    2011-02-01

    Since 1970's, the need of an automatic license plate recognition system, sometimes referred as Automatic License Plate Recognition system, has been increasing. A license plate recognition system is an automatic system that is able to recognize a license plate number, extracted from image sensors. In specific, Automatic License Plate Recognition systems are being used in conjunction with various transportation systems in application areas such as law enforcement (e.g. speed limit enforcement) and commercial usages such as parking enforcement and automatic toll payment private and public entrances, border control, theft and vandalism control. Vehicle license plate recognition has been intensively studied in many countries. Due to the different types of license plates being used, the requirement of an automatic license plate recognition system is different for each country. [License plate detection using cluster run length smoothing algorithm ].Generally, an automatic license plate localization and recognition system is made up of three modules; license plate localization, character segmentation and optical character recognition modules. This paper presents an Arabic license plate recognition system that is insensitive to character size, font, shape and orientation with extremely high accuracy rate. The proposed system is based on a combination of enhancement, license plate localization, morphological processing, and feature vector extraction using the Haar transform. The performance of the system is fast due to classification of alphabet and numerals based on the license plate organization. Experimental results for license plates of two different Arab countries show an average of 99 % successful license plate localization and recognition in a total of more than 20 different images captured from a complex outdoor environment. The results run times takes less time compared to conventional and many states of art methods.

  3. 基于SCADA--ZYT100智能供水自动控制系统%Intelligent Water Supply Automatic Control System Based on SCADA-ZYT100

    Institute of Scientific and Technical Information of China (English)

    李凯; 郭建珠

    2012-01-01

    The authors introduced features of SCADA--ZYT100 intelligent water supply automatic control system. According to application examples, the authors analyzed main functions of intelligent control system in detail based on SCADA- ZYT100, and put forward that ideas of reliability and total opening were new trend for industrial development.%介绍了SCADA—ZYT100智能供水自动控制系统的特点,根据应用实例,详细分析了基于SCADA—ZYT100智能控制系统的主要功能,提出了可靠、全开放为工业控制发展新趋势的理念。

  4. Automatic Control System Design for Offshore Oil Field Skid-mounted Filter Unit%海上油田橇装式滤器装置自动控制系统设计

    Institute of Scientific and Technical Information of China (English)

    韩延坤; 黄显德; 王建; 李曙彤

    2012-01-01

    A method of automatic control system design for skid-mounted filter unit was introduced. It is based on PLC manufactured by Siemens Company, combined with the instruments model selection. This unit can improve the original filter switch need artificial intervention and improve the degree of automation as well. The system's control function and design of software is also introduced in detail.%采用西门子可编程序控制器实现了海上油田橇装式滤器装置全自动控制的设计,提高了自动化程度,避免了原滤器切换需要人工干预带来的不便.

  5. Application of Automatic Generation Control in Yixing Pumped Storage Power Station%自动发电控制在宜兴抽水蓄能电站的应用

    Institute of Scientific and Technical Information of China (English)

    李海波; 仇岚

    2012-01-01

    The paper introduces the actual condition of generation units in the East China Yixing Pumped Storage Power Station.After expounding the 2 controlling methods,i.e.single unit and group units AGC(automatic generation control),the paper emphasizes the probabilities of hierarchy control in power station and presents the application of AGC in the power plant side.%介绍了华东宜兴抽水蓄能电站机组的实际情况,阐述了单机自动发电控制和成组控制2种控制方式,说明了电站分层控制的概念,介绍了自动发电控制在电厂侧的应用情况。

  6. Automatic Complexity Analysis

    DEFF Research Database (Denmark)

    Rosendahl, Mads

    1989-01-01

    One way to analyse programs is to to derive expressions for their computational behaviour. A time bound function (or worst-case complexity) gives an upper bound for the computation time as a function of the size of input. We describe a system to derive such time bounds automatically using abstract...

  7. Research and design on solar radio telescope observations automatic control platform%太阳射电望远镜自动观测控制平台的研究与设计

    Institute of Scientific and Technical Information of China (English)

    王冉; 殷兴辉

    2015-01-01

    In order to achieve an observer sitting in front of a computer without leaving home can be completed using a radio telescope observations the astronomical, based on laboratory radio spectrum analyzer, we propose an automatic observing solar radio telescope control platform for the overall solution. In VC++6.0 designed PC interface , MSP430F169 MCU as the next crew, PC control of MCU, lower machine control laboratory antenna azimuth and elevation movement, truly achieve the automatic control for the telescope. Experimental results show that the system is stable, we can achieve the purpose of the design.%为了实现观测者足不出户的坐在计算机面前就可以完成使用射电望远镜观测天体的任务,在实验室射电频谱仪的基础上,提出了一种太阳射电望远镜自动观测控制平台的整体解决方案。以 VC++6.0设计上位机界面,以MSP430F169单片机为下位机,上位机控制下位机使其控制实验室电机方位和俯仰的转动,真正实现对望远镜的自动控制。实验结果表明,该系统工作稳定,可以达到设计的目的。

  8. 基于S7-200 PLC 全自动搅拌和面机的设计与控制%Based on the S7-200 PLC Automatic Stirring Mixer Design and Control

    Institute of Scientific and Technical Information of China (English)

    姜鑫

    2015-01-01

    In this paper , a new design of automatic mixing kneading machine , the machine adopts S 7-200 control,PLC Siemens,can automatically complete with surface water ,stirring,molding process,launch,can also according to the actual needs of the user′s adjustment of flour ,water injection rate and stirring speed and time , in order to get the effect of different levels ,greatly improve the labor productivity and the use effect ,the promo-tion of a certain significance.%设计一种全自动搅拌和面机,整机采用西门子公司的S7-200型PLC控制,能够自动完成加面、加水、搅拌、推出成型等过程,也可根据用户的实际需求调整加面量、注水量和搅拌速度及时间,以期得到不同层次的面团效果,极大地提升了劳动生产率和使用效果,具有一定的推广意义.

  9. Study on Automatic Monitor and Control of Water-saving Irrigation on Urban Greenbelt%城市绿地节水灌溉自动控制研究

    Institute of Scientific and Technical Information of China (English)

    宋秀瑜; 张小侠; 王秀茹; 杨健; 王红雷

    2011-01-01

    That Increasingly scarce water resource has posed a serious threat to urban greenbelt in China's economic and social development. And water-saving irrigation been carried out has become an inevitable choice for the further development of the city, the precision irrigation as an important part of which has been of great importance to all parties. This article analyzed the theoretical basis to achieve automatic control of irrigation previously. Subsequently, the principle and form of urban greenbelt automatic water-saving irrigation systems were been introduced. Eventually, that the typical design for water-saving irrigation of urban greenbelt and the design of different plant configuration mode was completed.%水资源日益紧缺已经对中国经济社会发展构成了严重的威胁,开展城市绿地节水灌溉已成为城市进一步发展的必然选择,精准灌溉作为其中的重要一环得到了各方人士的重视.笔者首先分析自动控制灌溉实现的理论基础,然后介绍城市绿地自动节水灌溉系统的原理及组成,最后完成城市绿地节水灌溉的典型设计和不同植物配置模式的设计.

  10. WebBrowser控件和动态HTML在自动售票机中的应用研究%ON APPLICATION OF WEBBROWSER CONTROL AND DYNAMIC HTML IN AUTOMATIC TICKET VENDING MACHINE

    Institute of Scientific and Technical Information of China (English)

    庄涛; 楼生琳

    2012-01-01

    Automatic ticket vending machine (ATVM) is a station terminal equipment with graphic human-computer interactive interface in automatic fare collection system of city rail transit. Its human-computer interactive interface is an important component which can be used to the direct interaction between the ATVM applications and the ticket buyer. In this paper we study and apply the WebBrowser control and dynamic HTML page technique with embedded JavaScripts to realise human-computer interactive interface of ATVM, and describe in detail the relative implementation steps taking the ticket selling process as the example.%城市轨道交通自动售检票系统中的自动售票机是一种具有图形化人机交互界面的车站终端设备,人机交互界面是自动售票机应用程序与购票乘客之间进行直接互动的重要组成部分.研究和应用WebBrowser控件和嵌有JavaScript脚本的动态FHTML页面技术实现自动售票机的人机交互界面,并以售票过程为例详细描述了相关实现步骤.

  11. 14 CFR 171.267 - Glide path automatic monitor system.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Glide path automatic monitor system. 171... Landing System (ISMLS) § 171.267 Glide path automatic monitor system. (a) The ISMLS glide path equipment... control points when any of the following occurs: (1) A shift of the mean ISMLS glide path angle...

  12. 集装箱植物工厂自动控制系统建立%The Establish of Automatic Control System of the Container-type Plant Factory

    Institute of Scientific and Technical Information of China (English)

    赵倩; 王琨琦; 聂铭君; 陈晓丽; 王利春; 郭文忠; 薛绪掌

    2016-01-01

    For the Container-type Plant Factory,an automatic control system ,which contains the cycle of nutrient solu-tion,the artificial light and the tempreture inside , was established .This system aims at the feature of small volume and easy control of container .Simultaneously ,sues three low cost and better effect factors as controlled object ,according to op-timal control theory .System is developed ,based on the Programmable Logic Controller ( PLC) and a touch screen is used as the master computer .Programs make use of swich signal control principle to manage the nutrient solution and LED .At the same time ,adjust temperature inside container on the basis of closed-loop PID control .The screen will monitoring the whole process of the real-time changes about the environment inside and the nutrient solution .Meanwhile,control policy is determined automatically through various parameters invocation and computer programs are executed by mans of human-machine coordination .The experiment verified that the system could implement the layered cycle of the nutrient solution and regularly supply according to the control parameters manually set .And it could implement the conversion of different photoperiod by turning the LED on and off automatically , referring the time managers given .In addition , the tempreture could be controlled in a range which is suitable for the growth of plants by adjusting the temperature regulates organiza -tion.Thus,this low-cost and reliable control system could meet the demands crops need in Container-type Plant Facto-ry.%针对集装箱植物工厂体积小、可控性强的特征,利用最适化控制原理,针对控制成本低、控制效果好的营养液管理、人工补光、箱内环境温度3个因子,基于可编程控制器建立了一套自动控制系统。该系统将人机交互触摸屏作为上位机,采用开关量控制原理进行营养液循环和LED周期补光的管理;利用闭环 PID控制原理,进行箱内

  13. Automatic Guidance System for Welding Torches

    Science.gov (United States)

    Smith, H.; Wall, W.; Burns, M. R., Jr.

    1984-01-01

    Digital system automatically guides welding torch to produce squarebutt, V-groove and lap-joint weldments within tracking accuracy of +0.2 millimeter. Television camera observes and traverses weld joint, carrying welding torch behind. Image of joint digitized, and resulting data used to derive control signals that enable torch to track joint.

  14. Experimental Reform of Automatic Control Principle Based on CDIO Education Model%基于CDIO模式的自动控制原理实验改革探索

    Institute of Scientific and Technical Information of China (English)

    刘明华; 王彩霞

    2015-01-01

    CDIO engineering education model is the latest achievement of the interna-tional engineering education reform in recent years, and the principle requirements to improve the students’ ability in a comprehensive way, such as engineering fundamentals knowledge, personal skills, teamwork skills, and engineering capability. Automatic Control Principle is the core course of the automation, and the experiment is the bridge between control theory and practical engineering. The introduce of CDIO education model to the experimental teaching of Automatic Control Principle will improve the professional quality of students comprehensively, by setting the actual engineering objects as experiment contents, integrating the different courses of professional knowledge, and foster innovation and communication skills of students, lay a solid foundation for the future work.%CDIO工程教育模式是近年来国际工程教育改革的最新成果,其培养大纲要求以综合的培养方式全面提高学生的工程基础知识、个人能力、人际团队能力和工程系统能力。自动控制原理是自动化专业的核心课程,自动控制原理实验是连接控制理论与实际工程的桥梁。在实验教学中引入CDIO教育模式,通过设置以实际工程为对象的实验内容,将不同的专业课程知识进行系统的整合,全面提高学生的专业素质,同时培养学生的创新能力和沟通协调能力,为走向工作岗位打下坚实的基础。

  15. The design of remote control system for fully automatic rice cooker based on TCP/IP protocol%基于TCP/IP协议的全自动电饭煲远程控制系统设计

    Institute of Scientific and Technical Information of China (English)

    康志亮; 李开国; 许丽佳

    2011-01-01

    提出了一种全自动电饭煲远程控制系统的设计方案.采用精简的TCP/IP协议实现STC89C58RD+单片机与因特网络通信,STC89C58RD+单片机通过红外通信的方法控制全自动电饭煲.网站接受用户请求,网络程序处理与电饭煲微控制器之间的通信,微控制器实现对电饭煲的全自动控制.另外,在电饭煲原有的基础上,设计了储米、取米、淘米、放米、加水等机械装置,以实现电饭煲机电一体化.系统测试结果显示,该系统操作方便,成本低,稳定性高且扩展性好.%The paper designed a remote control system for fully automatic rice cooker. In this system a simplified TCP/IP protocol is applied to communicate intemet network with STC89C58RD+, and then the rice cooker is controlled by infrared communication method. The Website can accept request from user, and then the network programs can process the communication between internet network and the microcontroller which controls the fully automatic rice cooker. Additionally, some mechanical installations for storing rice, taking dee, washing rice, placing rice and adding water, are designed to achieve mechanical-electrical integration.The proposed system is tested, and the experiment results show that the system has some advantages such as simple operation, low cost, high stability and good expansibility.

  16. 层流炉二维PIV自动控制系统%Design and Experiment of the Two-dimensional PIV Automatic Control System for Laminar Entrained Flow Reactor

    Institute of Scientific and Technical Information of China (English)

    杨延强; 易维明; 李志合; 柏雪源; 李永军

    2012-01-01

    In the cold PIV (particle image velocimetry) system of the laminar entrained flow reactor, the relative position between the camera and the measuring tube was an important condition to ensure accurate test data. To make the PIV operation more convenient, accurate, and fast in the test, two-dimensional PIV automatic control system was designed. And the reliability of the system was tested in the cold simulation equipment of laminar flow furnace, compared with no using two-dimensional PIV automatic control system, the results showed that in different sections of the measuring tube, the particle speed of the axial center achieves a smooth transition, and eliminates the jump change; when collection distance is 350mm and main air flow rate is 1. 5 mVh, the relative error of particle residence time is 9. 218% ; and the operation saves time and effort in the test process. These suggested that the two-dimensional PIV automatic control system could satisfy the cold test of the laminar entrained flow reactor needs, achieve uniform and continuous test, reduce human error and improve the accuracy of test data.%在层流炉冷态粒子图像测速( PIV)系统中,相机与测量管的相对位置是保证试验数据精确的重要条件.为使试验过程中整个PIV系统操作起来更加方便、准确、快捷,设计了二维PIV自动控制系统,并在层流炉冷态模拟装置上对该系统的可靠性进行了试验验证.与没有使用二维PIV自动控制系统之前的试验结果相比:各测量段颗粒的轴向中心速度相互之间的衔接实现了平滑过渡,消除了跳跃性变化;收集距离为350 mm,主气流流量为1.5 m3/h时,层流炉内颗粒停留时间的相对误差为9.218%.说明该二维PIV自动控制系统能够满足层流炉冷态试验需要,实现了均匀、连续拍摄,减少了人为误差,提高了试验数据的准确性.

  17. Real-time automatic gain control algorithm based on linear TDICCD camera%采用线阵TDICCD相机的实时自动增益控制算法

    Institute of Scientific and Technical Information of China (English)

    彭妮娜; 陈大羽; 王琨; 包斌

    2011-01-01

    The camera dynamic range is a key property for the performance of remote sensor. If the camera have narrow dynamic range, part of images will be saturated in high end and some useful information lost or most of useful information is unused in high end and suppressed in low end. In order to improve the dynamic range of camera, the performance of remote sensor and the quality of remote image, the real-time automatic gain control technology was enhanced according to the real-time scenery and illumination condition. An algorithm for real-time automatic gain control was proposed based on the imaging principle of linear TDICCD camera. The real-time correction of the integral of linear TDICCD camera was achieved. The dynamic range of the camera was changed to adapt the different ground targets. The algorithm was embedded into the imaging circuit of linear TDICCD camera. At last, the experimental results show the correctness, stability and reliability of the algorithm for real-time automatic gain control.%动态范围是遥感器的一项重要性能指标,动态范围过窄会在图像中出现高端饱和、丢失信息或高端闲置、信息压缩在低端的情况.为提高相机的动态范围,需要根据成像景物和光照的实时变化调整信号增益,以最大程度地发挥相机的性能,提高相机成像质量.在深入研究线阵TDICCD的成像原理的基础上,提出了一种基于线阵TDICCD相机的实时自动增益控制算法,实现了星上实时调整TDICCD相机的积分级数,改变相机的动态范围,以适应不同的地面景物目标.并将其工程化应用到CCD相机视频电路成像链路中,通过试验验证了算法的正确性、稳定性和可靠性.

  18. Automatic exposure control in CT: the effect of patient size, anatomical region and prescribed modulation strength on tube current and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Papadakis, Antonios E. [University Hospital of Heraklion, Department of Medical Physics, Stavrakia, P.O. Box 1352, Heraklion, Crete (Greece); Perisinakis, Kostas; Damilakis, John [University of Crete, Faculty of Medicine, Department of Medical Physics, P.O. Box 2208, Heraklion, Crete (Greece)

    2014-10-15

    To study the effect of patient size, body region and modulation strength on tube current and image quality on CT examinations that use automatic tube current modulation (ATCM). Ten physical anthropomorphic phantoms that simulate an individual as neonate, 1-, 5-, 10-year-old and adult at various body habitus were employed. CT acquisition of head, neck, thorax and abdomen/pelvis was performed with ATCM activated at weak, average and strong modulation strength. The mean modulated mAs (mAs{sub mod}) values were recorded. Image noise was measured at selected anatomical sites. The mAs{sub mod} recorded for neonate compared to 10-year-old increased by 30 %, 14 %, 6 % and 53 % for head, neck, thorax and abdomen/pelvis, respectively, (P < 0.05). The mAs{sub mod} was lower than the preselected mAs with the exception of the 10-year-old phantom. In paediatric and adult phantoms, the mAs{sub mod} ranged from 44 and 53 for weak to 117 and 93 for strong modulation strength, respectively. At the same exposure parameters image noise increased with body size (P < 0.05). The ATCM system studied here may affect dose differently for different patient habitus. Dose may decrease for overweight adults but increase for children older than 5 years old. Care should be taken when implementing ATCM protocols to ensure that image quality is maintained. circle ATCM efficiency is related to the size of the patient's body. (orig.)

  19. 基于S7-200PLC全自动捆扎机控制系统%Control System Based on S7-200 PLC Automatic Strapping Machine

    Institute of Scientific and Technical Information of China (English)

    韩鹏; 朱奎林

    2016-01-01

    捆扎机采用继电-接触器控制系统,功能单一,存在多种缺点。在分析控制要求的基础上,采用西门子S7-200可编程控制器。设计了捆扎机主电路图、PLC输入输出连接电路图和制动及加热电路。完成了捆扎机循环工作流程图和相应梯形图程序。对PLC控制系统进行线路连接和机电联调,捆扎机能实现手动、自动、连续3种功能,达到控制要求。%The strapping machine adopts relay-contactor control system, has many disadvantages, and has single function. On the basis of the analysis and control requirements, the SIEMENS S7-200 programmable controller was adopted. The main circuit diagram of the strapping machine, the PLC input and output connection circuit diagram, the brake and the heating circuit were designed. The cycle flow chart and the ladder chart program of the strapping machine were completed. PLC control system for line connection and the electrical-mechanical alignment, the strapping machine can achieve manual, automatic and continuous 3 functions, to meet the control requirements.

  20. Automatic trend estimation

    CERN Document Server

    Vamos¸, C˘alin

    2013-01-01

    Our book introduces a method to evaluate the accuracy of trend estimation algorithms under conditions similar to those encountered in real time series processing. This method is based on Monte Carlo experiments with artificial time series numerically generated by an original algorithm. The second part of the book contains several automatic algorithms for trend estimation and time series partitioning. The source codes of the computer programs implementing these original automatic algorithms are given in the appendix and will be freely available on the web. The book contains clear statement of the conditions and the approximations under which the algorithms work, as well as the proper interpretation of their results. We illustrate the functioning of the analyzed algorithms by processing time series from astrophysics, finance, biophysics, and paleoclimatology. The numerical experiment method extensively used in our book is already in common use in computational and statistical physics.