WorldWideScience

Sample records for automated sequential injection-microcolumn

  1. On-line dynamic fractionation and automatic determination of inorganic phosphorous in environmental solid substrates exploiting sequential injection microcolumn extraction and flow injection analysi

    DEFF Research Database (Denmark)

    Buanuam, Janya; Miró, Manuel; Hansen, Elo Harald

    2006-01-01

    Sequential injection microcolumn extraction (SI-MCE) based on the implementation of a soil containing microcartridge as external reactor in a sequential injection network is, for the first time, proposed for dynamic fractionation of macronutrients in environmental solids, as exemplified by the pa......Sequential injection microcolumn extraction (SI-MCE) based on the implementation of a soil containing microcartridge as external reactor in a sequential injection network is, for the first time, proposed for dynamic fractionation of macronutrients in environmental solids, as exemplified...... by the partitioning of inorganic phosphorous in agricultural soils. The on-line fractionation method capitalises on the accurate metering and sequential exposure of the various extractants to the solid sample by application of programmable flow as precisely coordinated by a syringe pump. Three different soil phase...... associations for phosphorus, that is, exchangeable, Al- and Fe-bound and Ca-bound fractions, were elucidated by accommodation in the flow manifold of the 3 steps of the Hietjles-Litjkema (HL) scheme involving the use of 1.0 M NH4Cl, 0.1 M NaOH and 0.5 M HCl, respectively, as sequential leaching reagents...

  2. Utilizing a sequential injection system furnished with an extraction microcolumn as a novel approach for executing sequential extractions of metal species in solid samples

    DEFF Research Database (Denmark)

    Chomchoei, R.; Hansen, Elo Harald; Shiowatana, J.

    2007-01-01

    This communication presents a novel approach to perform sequential extraction of elements in solid samples by using a sequential injection (SI) system incorporating a specially designed extraction microcolumn. Based on the operation of the syringe pump, different modes of extraction are potentially...... that the system entails many advantages such as being fully automated, and besides being characterised by rapidity, ease of operation and robustness, it is less prone to risks of contamination and personal errors as encountered in traditional batch systems. Moreover, improvement of the precision and accuracy...... of the chemical fractionation of metal in solids as compared with previous reports are obtained. The system ensures that extraction is performed at designated pH values. Variation of sample weight to column volume ratios do not affect the amounts of extractable metals, nor do extraction flow rates ranging from 50...

  3. Coupling sequential injection on-line preconcentration using a PTFE beads packed column to direct injection nebulization inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2002-01-01

    An automated sequential injection on-line preconcentration procedure for trace metals by using a PTFE bead-packed microcolumn coupled to ICP-MS is described, and used for simultaneous analyses of cadmium and lead. In dilute nitric acid (0.5%, v/v), neutral complexes between the analytes...

  4. Coupling sequential injection on-line preconcentration by means of a renewable microcolumn with ion-exchange beads with detection by electrothermal atomic absorption spectrometry. Comparing the performance of eluting the loaded beads with transporting them directly into the graphite tube

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2001-01-01

    The design of a flow injection/sequential injection (FIA/SIA) on-line preconcentration system incorporating a renewable microcolumn with ion-exchange beads and interfaced with an electrothermal atomic absorption spectrometry (ETAAS) detector is described, and its practical applicability.......4% for the procedure in which the loaded beads are transported directly to the graphite furnace for pyrolysis and atomization, and even improved in comparison to the traditional unidirectional and bidirectional repetitive elution procedures which under comparable conditions yield R.S.D.-values of 5.8 and 4...

  5. Exploiting the bead-injection approach in the integrated sequential injection Lab-on-Valve format using hydrophobic packing materials for on-line matrix removal and preconcentration of trace levels of cadmium in environmental and biological samples via formation of non-charged chelates prior

    DEFF Research Database (Denmark)

    Miró, Manuel; Jonczyk, Sylwia; Wang, Jianhua

    2003-01-01

    The concept of renewable microcolumns within the conduits of an automated single injection lab-on-valve system was exploited in a sorption/elution fashion using sorbents of hydrophobic nature. The scheme's practical applicability was demonstrated for the electrothermal atomic absorption spectrome......The concept of renewable microcolumns within the conduits of an automated single injection lab-on-valve system was exploited in a sorption/elution fashion using sorbents of hydrophobic nature. The scheme's practical applicability was demonstrated for the electrothermal atomic absorption...

  6. Are Flow Injection-based Approaches Suitable for Automated Handling of Solid Samples?

    DEFF Research Database (Denmark)

    Miró, Manuel; Hansen, Elo Harald; Cerdà, Victor

    Flow-based approaches were originally conceived for liquid-phase analysis, implying that constituents in solid samples generally had to be transferred into the liquid state, via appropriate batch pretreatment procedures, prior to analysis. Yet, in recent years, much effort has been focused...... electrolytic or aqueous leaching, on-line dialysis/microdialysis, in-line filtration, and pervaporation-based procedures have been successfully implemented in continuous flow/flow injection systems. In this communication, the new generation of flow analysis, including sequential injection, multicommutated flow.......g., soils, sediments, sludges), and thus, ascertaining the potential mobility, bioavailability and eventual impact of anthropogenic elements on biota [2]. In this context, the principles of sequential injection-microcolumn extraction (SI-MCE) for dynamic fractionation are explained in detail along...

  7. Sequential injection on-line matrix removal and trace metal preconcentration using a PTFE beads packed column as demonstrated for the determination of cadmium by electrothermal atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2002-01-01

    A sequential injection (SI) on-line matrix removal and trace metal preconcentration procedure by using a novel microcolumn packed with PTFE beads is described, and demonstrated for trace cadmium analysis with detection by electrothermal atomic absorption spectrometry (ETAAS). The analyte...

  8. On-line dynamic extraction and automated determination of readily bioavailable hexavalent chromium in solid substrates using micro-sequential injection bead-injection lab-on-valve hyphenated with electrothermal atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Long, Xiangbao; Miró, Manuel; Hansen, Elo Harald

    2006-01-01

    A novel and miniaturized micro-sequential injection bead injection lab-on-valve (μSI-BI-LOV) fractionation system was developed for in-line microcolumn soil extraction under simulated environmental scenarios and accurate monitoring of the content of easily mobilisable hexavalent chromium in soil...... environments at the sub-low parts-per-million level. The flow system integrates dynamic leaching of hexavalent chromium using deionized water as recommended by the German Standard DIN 38414-S4 method; on-line pH adjustment of the extract by a 0.01 mol L-1 Tris-HNO3 buffer solution; isolation of the chromate...... polluted agricultural soil material (San Joaquin Soil-Baseline Trace Element Concentrations) with water-soluble Cr(VI) salts at different concentration levels. The potential of the μSI-BI-LOV set-up with renewable surfaces for flame-AAS determination of high levels of readily bioavailable chromate...

  9. Development of an automated sequential injection on-line solvent extraction-back extraction procedure as demonstrated for the determination of cadmium with detection by electrothermal atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2002-01-01

    An automated sequential injection (SI) on-line solvent extraction-back extraction separation/preconcentration procedure is described. Demonstrated for the assay of cadmium by electrothermal atomic absorption spectrometry (ETAAS), the analyte is initially complexed with ammonium pyrrolidinedithioc......An automated sequential injection (SI) on-line solvent extraction-back extraction separation/preconcentration procedure is described. Demonstrated for the assay of cadmium by electrothermal atomic absorption spectrometry (ETAAS), the analyte is initially complexed with ammonium....../preconcentration process of the ensuing sample. An enrichment factor of 21.4, a detection limit of 2.7 ng/l, along with a sampling frequency of 13s/h were obtained at a sample flow rate of 6.0mlmin/sup -1/. The precision (R.S.D.) at the 0.4 mug/l level was 1.8% as compared to 3.2% when quantifying the organic extractant...

  10. Coupling on-line preconcentration by ion-exchange with ETAAS. A novel flow injection approach based on the use of a renewable microcolumn as demonstrated for the determination of nickel in environmental and biological samples

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2000-01-01

    microcolumn incorporated within an integrated micro FI-system, the column is loaded with a defined volume of small beads of an SP Sephadex C-25 cation-exchange resin and subsequently exposed to a metered amount of sample solution. However, instead of eluting the retained analyte from the organic ion-exchange......A novel way of exploiting flow injection/sequential injection (FIA/SIA) on-line ion-exchange preconcentration with detection by electrothermal atomic absorption spectrometry (ETAAS) is described and demonstrated for the determination of trace-levels of nickel. Based on the use of a renewable...... resin, the beads are along with 30 mul of carrier (buffer) solution transported via air segmentation directly into the graphite tube, where they are ashed during the pyrolysis and atomization process. The ETAAS determination is performed in parallel with the preconcentration process of the ensuing...

  11. On-line ion exchange preconcentration in a sequential injection lab-on-valve microsystem incorporating a renewable column with ETAAS for the trace-level determination of bismuth in urine and river sediment

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2001-01-01

    A sequential injection system for on-line ion-exchange separation and preconcentration of trace-level amounts of metal ions with ensuing detection by electrothermal atomic absorption spectrometry (ETAAS) is described. Based on the use of a renewable microcolumn incorporated within an integrated l.......3% for the determination of 2.0 mug/l Bi (n = 7). The procedure was validated by determination of bismuth in a certified reference material CRM 320 (river sediment), and by bismuth spike recoveries in two human urine samples....

  12. Sequential-Injection Analysis: Principles, Instrument Construction, and Demonstration by a Simple Experiment

    Science.gov (United States)

    Economou, A.; Tzanavaras, P. D.; Themelis, D. G.

    2005-01-01

    The sequential-injection analysis (SIA) is an approach to sample handling that enables the automation of manual wet-chemistry procedures in a rapid, precise and efficient manner. The experiments using SIA fits well in the course of Instrumental Chemical Analysis and especially in the section of Automatic Methods of analysis provided by chemistry…

  13. Low energy microcolumn for large field view inspection

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Chul [Department of Optometry, Eulji University, 212 Yangji-dong, Sujeong-gu, Seongnam-si, Gyeonggi-do 461-713 (Korea, Republic of); Ahn, Seung-Joon; Oh, Tae-Sik; Kim, Dae-Wook [Department of Nanoscience, Sun Moon University 100 Kalsan-ri, Tangjeong-myun, Asan-si, Chungnam 336-708 (Korea, Republic of); Kim, Ho-Seob, E-mail: hskim3@sunmoon.ac.kr [Department of Nanoscience, Sun Moon University 100 Kalsan-ri, Tangjeong-myun, Asan-si, Chungnam 336-708 (Korea, Republic of); Jang, Won Kweon [Division of Electronic, Computer and Communication Engineering, Hanseo University 360 DaeKook-ri, Haemi-myun, Seosan-si, Chungnam 356-706 (Korea, Republic of)

    2011-12-15

    Since the development of microcolumn system, it attracted much attention because multiple microcolumns can be assembled into arrayed form, which is expected to generate multiple electron beams and overcome the disadvantage of electron beam inspection equipments, low throughput . However, it is not easy to apply a microcolumn to the practical inspection or testing equipment since its scanning area is too small. Even if the arrayed operation using multiple microcolumns can overcome this limit, it requires complicated supporting systems and related technologies to operate a number of microcolumns simultaneously. Therefore, we tried to modify microcolumn design itself so that it can have a large field of view. In this work, two kinds of modified columns will be suggested and the preliminary results showing their performance of scanning large area will be discussed. -- Highlights: Black-Right-Pointing-Pointer Two types of microcolumn designs to achieve a large field of view are fabricated. Black-Right-Pointing-Pointer Field of view of a microcolumn increases linearly with the working distance. Black-Right-Pointing-Pointer New designed microcolumns can be developed as a low energy column system for large view inspections.

  14. On-line sample-pre-treatment schemes for trace-level determinations of metals by coupling flow injection or sequential injection with ICP-MS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2003-01-01

    a polytetrafluoroethylene (PTFE) knotted reactor (KR), solvent extraction-back extraction and hydride/vapor generation. It also addresses a novel, robust approach, whereby the protocol of SI-LOV-bead injection (BI) on-line separation and pre-concentration of ultra-trace levels of metals by a renewable microcolumn...

  15. Polymeric microchip for the simultaneous determination of anions and cations by hydrodynamic injection using a dual-channel sequential injection microchip electrophoresis system.

    Science.gov (United States)

    Gaudry, Adam J; Nai, Yi Heng; Guijt, Rosanne M; Breadmore, Michael C

    2014-04-01

    A dual-channel sequential injection microchip capillary electrophoresis system with pressure-driven injection is demonstrated for simultaneous separations of anions and cations from a single sample. The poly(methyl methacrylate) (PMMA) microchips feature integral in-plane contactless conductivity detection electrodes. A novel, hydrodynamic "split-injection" method utilizes background electrolyte (BGE) sheathing to gate the sample flows, while control over the injection volume is achieved by balancing hydrodynamic resistances using external hydrodynamic resistors. Injection is realized by a unique flow-through interface, allowing for automated, continuous sampling for sequential injection analysis by microchip electrophoresis. The developed system was very robust, with individual microchips used for up to 2000 analyses with lifetimes limited by irreversible blockages of the microchannels. The unique dual-channel geometry was demonstrated by the simultaneous separation of three cations and three anions in individual microchannels in under 40 s with limits of detection (LODs) ranging from 1.5 to 24 μM. From a series of 100 sequential injections the %RSDs were determined for every fifth run, resulting in %RSDs for migration times that ranged from 0.3 to 0.7 (n = 20) and 2.3 to 4.5 for peak area (n = 20). This system offers low LODs and a high degree of reproducibility and robustness while the hydrodynamic injection eliminates electrokinetic bias during injection, making it attractive for a wide range of rapid, sensitive, and quantitative online analytical applications.

  16. Automated magnetic sorbent extraction based on octadecylsilane functionalized maghemite magnetic particles in a sequential injection system coupled with electrothermal atomic absorption spectrometry for metal determination.

    Science.gov (United States)

    Giakisikli, Georgia; Anthemidis, Aristidis N

    2013-06-15

    A new automatic sequential injection (SI) system for on-line magnetic sorbent extraction coupled with electrothermal atomic absorption spectrometry (ETAAS) has been successfully developed for metal determination. In this work, we reported effective on-line immobilization of magnetic silica particles into a microcolumn by the external force of two strong neodymium iron boron (NdFeB) magnets across it, avoiding the use of frits. Octadecylsilane functionalized maghemite magnetic particles were used as sorbent material. The potentials of the system were demonstrated for trace cadmium determination in water samples. The method was based on the on-line complex formation with diethyldithiocarbamate (DDTC), retention of Cd-DDTC on the surface of the MPs and elution with isobutyl methyl ketone (IBMK). The formation mechanism of the magnetic solid phase packed column and all critical parameters (chemical, flow, graphite furnace) influencing the performance of the system were optimized and offered good analytical characteristics. For 5 mL sample volume, a detection limit of 3 ng L(-1), a relative standard deviation of 3.9% at 50 ng L(-1) level (n=11) and a linear range of 9-350 ng L(-1) were obtained. The column remained stable for more than 600 cycles keeping the cost down in routine analysis. The proposed method was evaluated by analyzing certified reference materials and natural waters. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Recent developments in automated determinations of trace level concentrations of elements and on-line fractionations schemes exploiting the micro-sequential injection - lab-on-valve approach

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Miró, Manuel; Long, Xiangbao

    2006-01-01

    The determination of trace level concentrations of elements, such as metal species, in complex matrices by atomic absorption or emission spectrometric methods often require appropriate pretreatments comprising separation of the analyte from interfering constituents and analyte preconcentration...... are presented as based on the exploitation of micro-sequential injection (μSI-LOV) using hydrophobic as well as hydrophilic bead materials. The examples given comprise the presentation of a universal approach for SPE-assays, front-end speciation of Cr(III) and Cr(VI) in a fully automated and enclosed set...

  18. Development of a fully automated sequential injection solid-phase extraction procedure coupled to liquid chromatography to determine free 2-hydroxy-4-methoxybenzophenone and 2-hydroxy-4-methoxybenzophenone-5-sulphonic acid in human urine.

    Science.gov (United States)

    León, Zacarías; Chisvert, Alberto; Balaguer, Angel; Salvador, Amparo

    2010-04-07

    2-Hydroxy-4-methoxybenzophenone and 2-hydroxy-4-methoxybenzophenone-5-sulphonic acid, commonly known as benzophenone-3 (BZ3) and benzophenone-4 (BZ4), respectively, are substances widely used as UV filters in cosmetic products in order to absorb UV radiation and protect human skin from direct exposure to the deleterious wavelengths of sunlight. As with other UV filters, there is evidence of their percutaneous absorption. This work describes an analytical method developed to determine trace levels of free BZ3 and BZ4 in human urine. The methodology is based on a solid-phase extraction (SPE) procedure for clean-up and pre-concentration, followed by the monitoring of the UV filters by liquid chromatography-ultraviolet spectrophotometry detection (LC-UV). In order to improve not only the sensitivity and selectivity, but also the precision of the method, the principle of sequential injection analysis was used to automate the SPE process and to transfer the eluates from the SPE to the LC system. The application of a six-channel valve as an interface for the switching arrangements successfully allowed the on-line connection of SPE sample processing with LC analysis. The SPE process for BZ3 and BZ4 was performed using octadecyl (C18) and diethylaminopropyl (DEA) modified silica microcolumns, respectively, in which the analytes were retained and eluted selectively. Due to the matrix effects, the determination was based on standard addition quantification and was fully validated. The relative standard deviations of the results were 13% and 6% for BZ3 and BZ4, respectively, whereas the limits of detection were 60 and 30 ng mL(-1), respectively. The method was satisfactorily applied to determine BZ3 and BZ4 in urine from volunteers that had applied a sunscreen cosmetic containing both UV filters. Copyright 2010 Elsevier B.V. All rights reserved.

  19. Development of a fully automated sequential injection solid-phase extraction procedure coupled to liquid chromatography to determine free 2-hydroxy-4-methoxybenzophenone and 2-hydroxy-4-methoxybenzophenone-5-sulphonic acid in human urine

    International Nuclear Information System (INIS)

    Leon, Zacarias; Chisvert, Alberto; Balaguer, Angel; Salvador, Amparo

    2010-01-01

    2-Hydroxy-4-methoxybenzophenone and 2-hydroxy-4-methoxybenzophenone-5-sulphonic acid, commonly known as benzophenone-3 (BZ3) and benzophenone-4 (BZ4), respectively, are substances widely used as UV filters in cosmetic products in order to absorb UV radiation and protect human skin from direct exposure to the deleterious wavelengths of sunlight. As with other UV filters, there is evidence of their percutaneous absorption. This work describes an analytical method developed to determine trace levels of free BZ3 and BZ4 in human urine. The methodology is based on a solid-phase extraction (SPE) procedure for clean-up and pre-concentration, followed by the monitoring of the UV filters by liquid chromatography-ultraviolet spectrophotometry detection (LC-UV). In order to improve not only the sensitivity and selectivity, but also the precision of the method, the principle of sequential injection analysis was used to automate the SPE process and to transfer the eluates from the SPE to the LC system. The application of a six-channel valve as an interface for the switching arrangements successfully allowed the on-line connection of SPE sample processing with LC analysis. The SPE process for BZ3 and BZ4 was performed using octadecyl (C18) and diethylaminopropyl (DEA) modified silica microcolumns, respectively, in which the analytes were retained and eluted selectively. Due to the matrix effects, the determination was based on standard addition quantification and was fully validated. The relative standard deviations of the results were 13% and 6% for BZ3 and BZ4, respectively, whereas the limits of detection were 60 and 30 ng mL -1 , respectively. The method was satisfactorily applied to determine BZ3 and BZ4 in urine from volunteers that had applied a sunscreen cosmetic containing both UV filters.

  20. An on-line potentiometric sequential injection titration process analyser for the determination of acetic acid.

    Science.gov (United States)

    van Staden, J F; Mashamba, Mulalo G; Stefan, Raluca I

    2002-09-01

    An on-line potentiometric sequential injection titration process analyser for the determination of acetic acid is proposed. A solution of 0.1 mol L(-1) sodium chloride is used as carrier. Titration is achieved by aspirating acetic acid samples between two strong base-zone volumes into a holding coil and by channelling the stack of well-defined zones with flow reversal through a reaction coil to a potentiometric sensor where the peak widths were measured. A linear relationship between peak width and logarithm of the acid concentration was obtained in the range 1-9 g/100 mL. Vinegar samples were analysed without any sample pre-treatment. The method has a relative standard deviation of 0.4% with a sample frequency of 28 samples per hour. The results revealed good agreement between the proposed sequential injection and an automated batch titration method.

  1. Flow injection analysis: Emerging tool for laboratory automation in radiochemistry

    International Nuclear Information System (INIS)

    Egorov, O.; Ruzicka, J.; Grate, J.W.; Janata, J.

    1996-01-01

    Automation of routine and serial assays is a common practice of modern analytical laboratory, while it is virtually nonexistent in the field of radiochemistry. Flow injection analysis (FIA) is a general solution handling methodology that has been extensively used for automation of routine assays in many areas of analytical chemistry. Reproducible automated solution handling and on-line separation capabilities are among several distinctive features that make FI a very promising, yet under utilized tool for automation in analytical radiochemistry. The potential of the technique is demonstrated through the development of an automated 90 Sr analyzer and its application in the analysis of tank waste samples from the Hanford site. Sequential injection (SI), the latest generation of FIA, is used to rapidly separate 90 Sr from interfering radionuclides and deliver separated Sr zone to a flow-through liquid scintillation detector. The separation is performed on a mini column containing Sr-specific sorbent extraction material, which selectively retains Sr under acidic conditions. The 90 Sr is eluted with water, mixed with scintillation cocktail, and sent through the flow cell of a flow through counter, where 90 Sr radioactivity is detected as a transient signal. Both peak area and peak height can be used for quantification of sample radioactivity. Alternatively, stopped flow detection can be performed to improve detection precision for low activity samples. The authors current research activities are focused on expansion of radiochemical applications of FIA methodology, with an ultimate goal of creating a set of automated methods that will cover the basic needs of radiochemical analysis at the Hanford site. The results of preliminary experiments indicate that FIA is a highly suitable technique for the automation of chemically more challenging separations, such as separation of actinide elements

  2. Sequential injection lab-on-valve: the third generation of flow injection analysis

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2003-01-01

    Termed the third generation of flow injection analysis, sequential injection (SI)-lab-on-valve (LOV) has specific advantages and allows novel, unique applications - not least as a versatile front end to a variety of detection techniques. This review presents snd discusses progress to date of the ...

  3. Exploiting an automated microfluidic hydrodynamic sequential injection system for determination of phosphate.

    Science.gov (United States)

    Khongpet, Wanpen; Pencharee, Somkid; Puangpila, Chanida; Kradtap Hartwell, Supaporn; Lapanantnoppakhun, Somchai; Jakmunee, Jaroon

    2018-01-15

    A microfluidic hydrodynamic sequential injection (μHSI) spectrophotometric system was designed and fabricated. The system was built by laser engraving a manifold pattern on an acrylic block and sealing with another flat acrylic plate to form a microfluidic channel platform. The platform was incorporated with small solenoid valves to obtain a portable setup for programmable control of the liquid flow into the channel according to the HSI principle. The system was demonstrated for the determination of phosphate using a molybdenum blue method. An ascorbic acid, standard or sample, and acidic molybdate solutions were sequentially aspirated to fill the channel forming a stack zone before flowing to the detector. Under the optimum condition, a linear calibration graph in the range of 0.1-6mg P L -1 was obtained. The detection limit was 0.1mgL -1 . The system is compact (5.0mm thick, 80mm wide × 140mm long), durable, portable, cost-effective, and consumes little amount of chemicals (83μL each of molybdate and ascorbic acid, 133μL of the sample solution and 1.7mL of water carrier/run). It was applied for the determination of phosphate content in extracted soil samples. The percent recoveries of the analysis were obtained in the range of 91.2-107.3. The results obtained agreed well with those of the batch spectrophotometric method. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Sequential injection approach for simultaneous determination of ultratrace plutonium and neptunium in urine with accelerator mass spectrometry

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per

    2013-01-01

    An analytical method was developed for simultaneous determination of ultratrace level plutonium (Pu) and neptunium (Np) using iron hydroxide coprecipitation in combination with automated sequential injection extraction chromatography separation and accelerator mass spectrometry (AMS) measurement...... show that preboiling and aging are important for obtaining high chemical yields for both Pu and Np, which is possibly related to the aggregation and adsorption behavior of organic substances contained in urine. Although the optimal condition for Np and Pu simultaneous determination requires 5-day aging...

  5. Submicrometric Magnetic Nanoporous Carbons Derived from Metal-Organic Frameworks Enabling Automated Electromagnet-Assisted Online Solid-Phase Extraction.

    Science.gov (United States)

    Frizzarin, Rejane M; Palomino Cabello, Carlos; Bauzà, Maria Del Mar; Portugal, Lindomar A; Maya, Fernando; Cerdà, Víctor; Estela, José M; Turnes Palomino, Gemma

    2016-07-19

    We present the first application of submicrometric magnetic nanoporous carbons (μMNPCs) as sorbents for automated solid-phase extraction (SPE). Small zeolitic imidazolate framework-67 crystals are obtained at room temperature and directly carbonized under an inert atmosphere to obtain submicrometric nanoporous carbons containing magnetic cobalt nanoparticles. The μMNPCs have a high contact area, high stability, and their preparation is simple and cost-effective. The prepared μMNPCs are exploited as sorbents in a microcolumn format in a sequential injection analysis (SIA) system with online spectrophotometric detection, which includes a specially designed three-dimensional (3D)-printed holder containing an automatically actuated electromagnet. The combined action of permanent magnets and an automatically actuated electromagnet enabled the movement of the solid bed of particles inside the microcolumn, preventing their aggregation, increasing the versatility of the system, and increasing the preconcentration efficiency. The method was optimized using a full factorial design and Doehlert Matrix. The developed system was applied to the determination of anionic surfactants, exploiting the retention of the ion-pairs formed with Methylene Blue on the μMNPC. Using sodium dodecyl sulfate as a model analyte, quantification was linear from 50 to 1000 μg L(-1), and the detection limit was equal to 17.5 μg L(-1), the coefficient of variation (n = 8; 100 μg L(-1)) was 2.7%, and the analysis throughput was 13 h(-1). The developed approach was applied to the determination of anionic surfactants in water samples (natural water, groundwater, and wastewater), yielding recoveries of 93% to 110% (95% confidence level).

  6. Microcolumns with self-assembled particle frits for proteomics

    DEFF Research Database (Denmark)

    Ishihama, Yasushi; Rappsilber, Juri; Andersen, Jens S

    2002-01-01

    LC-MS-MS experiments in proteomics are usually performed with packed microcolumns employing frits or outlets smaller than the particle diameter to retain the packing material. We have developed packed microcolumns using self-assembled particles (SAPs) as frits that are smaller than the size...... of the outlet. A five to one ratio of outlet size to particle diameter appears to be the upper maximum. In these situations the particles assembled into an arch over the outlet like the stones in a stone bridge. When 3 microm particles were packed into a tapered column with an 8 microm outlet, two particles...

  7. Development of a sequential injection-square wave voltammetry method for determination of paraquat in water samples employing the hanging mercury drop electrode.

    Science.gov (United States)

    dos Santos, Luciana B O; Infante, Carlos M C; Masini, Jorge C

    2010-03-01

    This work describes the development and optimization of a sequential injection method to automate the determination of paraquat by square-wave voltammetry employing a hanging mercury drop electrode. Automation by sequential injection enhanced the sampling throughput, improving the sensitivity and precision of the measurements as a consequence of the highly reproducible and efficient conditions of mass transport of the analyte toward the electrode surface. For instance, 212 analyses can be made per hour if the sample/standard solution is prepared off-line and the sequential injection system is used just to inject the solution towards the flow cell. In-line sample conditioning reduces the sampling frequency to 44 h(-1). Experiments were performed in 0.10 M NaCl, which was the carrier solution, using a frequency of 200 Hz, a pulse height of 25 mV, a potential step of 2 mV, and a flow rate of 100 µL s(-1). For a concentration range between 0.010 and 0.25 mg L(-1), the current (i(p), µA) read at the potential corresponding to the peak maximum fitted the following linear equation with the paraquat concentration (mg L(-1)): i(p) = (-20.5 ± 0.3)C (paraquat) - (0.02 ± 0.03). The limits of detection and quantification were 2.0 and 7.0 µg L(-1), respectively. The accuracy of the method was evaluated by recovery studies using spiked water samples that were also analyzed by molecular absorption spectrophotometry after reduction of paraquat with sodium dithionite in an alkaline medium. No evidence of statistically significant differences between the two methods was observed at the 95% confidence level.

  8. An automatic system for acidity determination based on sequential injection titration and the monosegmented flow approach.

    Science.gov (United States)

    Kozak, Joanna; Wójtowicz, Marzena; Gawenda, Nadzieja; Kościelniak, Paweł

    2011-06-15

    An automatic sequential injection system, combining monosegmented flow analysis, sequential injection analysis and sequential injection titration is proposed for acidity determination. The system enables controllable sample dilution and generation of standards of required concentration in a monosegmented sequential injection manner, sequential injection titration of the prepared solutions, data collecting, and handling. It has been tested on spectrophotometric determination of acetic, citric and phosphoric acids with sodium hydroxide used as a titrant and phenolphthalein or thymolphthalein (in the case of phosphoric acid determination) as indicators. Accuracy better than |4.4|% (RE) and repeatability better than 2.9% (RSD) have been obtained. It has been applied to the determination of total acidity in vinegars and various soft drinks. The system provides low sample (less than 0.3 mL) consumption. On average, analysis of a sample takes several minutes. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Sequential Injection Method for Rapid and Simultaneous Determination of 236U, 237Np, and Pu Isotopes in Seawater

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Steier, Peter

    2013-01-01

    An automated analytical method implemented in a novel dual-column tandem sequential injection (SI) system was developed for simultaneous determination of 236U, 237Np, 239Pu, and 240Pu in seawater samples. A combination of TEVA and UTEVA extraction chromatography was exploited to separate and purify...... target analytes, whereupon plutonium and neptunium were simultaneously isolated and purified on TEVA, while uranium was collected on UTEVA. The separation behavior of U, Np, and Pu on TEVA–UTEVA columns was investigated in detail in order to achieve high chemical yields and complete purification...

  10. Trends and perspectives of flow injection/sequential injection on-line sample-pretreatment schemes coupled to ETAAS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2005-01-01

    Flow injection (FI) analysis, the first generation of this technique, became in the 1990s supplemented by its second generation, sequential injection (SI), and most recently by the third generation (i.e.,Lab-on-Valve). The dominant role played by FI in automatic, on-line, sample pretreatments in ...

  11. A multisyringe flow-through sequential extraction system for on-line monitoring of orthophosphate in soils and sediments

    DEFF Research Database (Denmark)

    Buanuam, Janya; Miró, Manuel; Hansen, Elo Harald

    2007-01-01

    A fully automated flow-through microcolumn fractionation system with on-line post-extraction derivatization is proposed for monitoring of orthophosphate in solid samples of environmental relevance. The system integrates dynamic sequential extraction using 1.0 mol l-1 NH4Cl, 0.1 mol l-1 NaOH and 0...... of the operational times from days to hours, highly temporal resolution of the leaching process, and the capability for immediate decision for stopping or proceeding with the ongoing extraction. Very importantly, accurate determination of the various orthophosphate pools is ensured by minimization of the hydrolysis...... of extracted organic phosphorus and condensed inorganic phosphates within the time frame of the assay. The potential of the novel system for accommodation of the harmonized protocol from the Standards, Measurement and Testing (SMT) Program of the Commission of the European Communities for inorganic phosphorus...

  12. Fabrication of a micrometer Ni–Cu alloy column coupled with a Cu micro-column for thermal measurement

    International Nuclear Information System (INIS)

    Lin, J C; Chang, T K; Yang, J H; Jeng, J H; Lee, D L; Jiang, S B

    2009-01-01

    Micrometer Ni–Cu alloy columns have been fabricated by the micro-anode-guided electroplating (MAGE) process in the citrate bath. The surface morphology and chemical composition of the micro-columns were determined by copper concentration in the bath and by the electrical bias of MAGE. When fabricated in a bath of dilute copper (i.e. 4 mM) at lower voltages (e.g. 3.8 and 4.0 V), the alloy micro-columns revealed uniform diameter and smooth appearance. The alloy composition demonstrated an increase in the wt% ratio of Ni/Cu from 75/25, 80/20, 83/17 to 87/13 with increasing electrical bias from 3.8, 4.0, 4.2 to 4.4 V. However, it decreases from 75/25, 57/43 to 47/53 with increasing copper concentration from 4, 8 to 12 mM in the bath. Citrate plays a role in forming complexes with nickel and copper at similar reduction potentials, thus reducing simultaneously to Ni–Cu alloy. The mechanism for fabricating alloy micro-columns could be delineated on the basis of cathodic polarization of the complexes. A couple of micro-columns were fabricated using MAGE in constructing a pure copper micro-column on the top of a Ni/Cu (at 47/53) alloy micro-column. This micro-thermocouple provides a satisfactory measurement with good sensitivity and precision

  13. In vivo comparison of simultaneous versus sequential injection technique for thermochemical ablation in a porcine model.

    Science.gov (United States)

    Cressman, Erik N K; Shenoi, Mithun M; Edelman, Theresa L; Geeslin, Matthew G; Hennings, Leah J; Zhang, Yan; Iaizzo, Paul A; Bischof, John C

    2012-01-01

    To investigate simultaneous and sequential injection thermochemical ablation in a porcine model, and compare them to sham and acid-only ablation. This IACUC-approved study involved 11 pigs in an acute setting. Ultrasound was used to guide placement of a thermocouple probe and coaxial device designed for thermochemical ablation. Solutions of 10 M acetic acid and NaOH were used in the study. Four injections per pig were performed in identical order at a total rate of 4 mL/min: saline sham, simultaneous, sequential, and acid only. Volume and sphericity of zones of coagulation were measured. Fixed specimens were examined by H&E stain. Average coagulation volumes were 11.2 mL (simultaneous), 19.0 mL (sequential) and 4.4 mL (acid). The highest temperature, 81.3°C, was obtained with simultaneous injection. Average temperatures were 61.1°C (simultaneous), 47.7°C (sequential) and 39.5°C (acid only). Sphericity coefficients (0.83-0.89) had no statistically significant difference among conditions. Thermochemical ablation produced substantial volumes of coagulated tissues relative to the amounts of reagents injected, considerably greater than acid alone in either technique employed. The largest volumes were obtained with sequential injection, yet this came at a price in one case of cardiac arrest. Simultaneous injection yielded the highest recorded temperatures and may be tolerated as well as or better than acid injection alone. Although this pilot study did not show a clear advantage for either sequential or simultaneous methods, the results indicate that thermochemical ablation is attractive for further investigation with regard to both safety and efficacy.

  14. Sequential injection-bead injection-lab-on-valve schemes for on-line solid phase extraction and preconcentration of ultra-trace levels of heavy metals with determination by electrothermal atomic absorption spectrometry and inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Wang Jianhua; Hansen, Elo Harald; Miro, Manuel

    2003-01-01

    This communication presents an overview of the state-of-the-art of the exploitation of sequential injection (SI)-bead injection (BI)-lab-on-valve (LOV) schemes for automatic on-line sample pre-treatments interfaced with ETAAS and ICPMS detection as conducted in the authors' group. The discussions are focused on the applications of SI-BI-LOV protocols for on-line microcolumn based solid phase extraction of ultra-trace levels of heavy metals, employing the so-called renewable surface separation and preconcentration manipulatory scheme. Two types of sorbents have been employed as packing material, that is, the hydrophilic SP Sephadex C-25 cation exchange and iminodiacetate based Muromac A-1 chelating resins, and the hydrophobic poly(tetrafluoroethylene) (PTFE) and poly(styrene-divinylbenzene) copolymer alkylated with octadecyl groups (C 18 -PS/DVB). Using ETAAS as detection device, the easy-to-handle hydrophilic renewable reactors hold the features of improved R.S.D.s and LODs as compared to those operated in the conventional, permanent mode, in addition to the elimination of flow resistance. The hydrophobic columns fall into two categories, that is, the renewable one packed with C 18 -PS/DVB beads entails analogous R.S.D.s and LODs with respect to the conventional approach, while those with PTFE beads result in slightly inferior R.S.D.s and LODs by similar comparison, yet offering a wider dynamic range than when using an external permanent column. Moreover, the hydrophilic materials result in much higher enrichment of the analyte than the hydrophobic ones, although PTFE is the packing material that exhibits the best retention efficiency

  15. Photocatalytic and photoelectrochemical performance of Ta{sub 3}N{sub 5} microcolumn films fabricated using facile reactive sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Der-Hwa [Department of Materials Science and Engineering, National Cheng Kung University, No. 1 University Road, Tainan City 70101, Taiwan (China); Chang, Kao-Shuo, E-mail: kschang@mail.ncku.edu.tw [Department of Materials Science and Engineering, National Cheng Kung University, No. 1 University Road, Tainan City 70101, Taiwan (China); Promotion Center for Global Materials Research, National Cheng Kung University, No. 1 University Road, Tainan City 70101, Taiwan (China)

    2016-08-21

    This paper presents the photocatalytic and photoelectrochemical (PEC) properties of Ta{sub 3}N{sub 5} microcolumn films. The highlights include (1) overcoming the fundamental barrier of standard reactive sputtering for fabricating microcolumns; (2) preventing unnecessary complexity from complicating facile sputtering; (3) an alternative but effective approach for fabricating Ta{sub 3}N{sub 5} without using caustic NH{sub 3} gases; (4) investigating morphology tuning for favorable photocatalysis and PEC reactions; and (5) elucidating the relationships of the structures, morphologies, and properties of Ta{sub 3}N{sub 5} microcolumns. High-resolution transmission electron microscopy and selective-area electron diffraction verified the polycrystallinity of Ta{sub 3}N{sub 5} microcolumns, of which the elemental compositions and stoichiometry were measured using electron-probe energy dispersive spectroscopy, Auger electron spectroscopy, and X-ray photoelectron spectroscopy. The corresponding band gap was determined to be approximately 2.1 eV. The sample exhibited a superior photodegradation capability; the photodegradation rate constant k was determined to be approximately 1.4 times higher than that of P25 under UV irradiation. A photocatalytic and PEC cycling test indicated the photodegradation reusability and photostability of the Ta{sub 3}N{sub 5} microcolumns. The incident photon-to-current efficiency performance reached 6%, suggesting that these microcolumns hold potential for application in PEC devices.

  16. Optimization of electrostatic lens systems for low-energy scanning microcolumn applications

    International Nuclear Information System (INIS)

    Oh, Tae-Sik; Kim, Dae-Wook; Ahn, Seungjoon; Kim, Young Chul; Kim, Ho-Seob; Ahn, Seong Joon

    2008-01-01

    The optimization of a low-energy scanning microcolumn is proposed by adopting a modified Einzel lens sandwiched between an aligner and a deflector. The modified Einzel lens is composed of four electrodes, and the two center electrodes are specially designed quadrupole lenses having keyhole type rather than circular apertures. The outer electrodes of the Einzel lens having circular apertures are grounded, and the quadrupole lens is operated by applying the quadrupole voltages. The effects of the separated deflector system and the static quadrupole lens were investigated by analyzing the scanning electron beam spot at the target, and the results show that the proposed system can improve the performance of the scanning microcolumn

  17. Sequential MR images of uterus after Gd-DTPA injection

    International Nuclear Information System (INIS)

    Okada, Susumu; Kato, Tomoyasu; Yamada, Keiko; Sawano, Seishi; Yamashita, Takashi; Hirai, Yasuo; Hasumi, Katsuhiko

    1993-01-01

    To investigate the sequential changes in signal intensity (SI) of normal and abnormal uteri, T1-weighted images were taken repeatedly after the injection of Gd-diethylenetriaminepentaacetic acid (DTPA). Six volunteers and 19 patients with known uterine body malignancy (18 carcinomas, one carcinosarcoma) were examined. The results in volunteers were as follows. In the secretory phase, SI of the endometrium was stronger in the late images than in the early ones, whereas in the proliferative phase, SI was stronger in the early images. SI of the myometrium decreased rapidly and there were no differences in SI between menstrual phases. In 17 of 18 endometrial carcinomas, the tumors showed hypointensity relative to the myometrium, and the contrast between the tumor and the myometrium was better in the early images. In the remaining two cases, the tumor showed hyperintensity and the contrast was better in the late images. After the injection of Gd-DTPA, the endometrium appeared differently according to the menstrual cycle in normal volunteers, and the appearance of uterine structures and endometrial malignant tumors changed sequentially. These findings must be kept in mind when evaluating uterine diseases by Gd-DTPA enhanced MRI. (author)

  18. Simultaneous determination of two active components of pharmaceutical preparations by sequential injection method using heteropoly complexes

    Directory of Open Access Journals (Sweden)

    Mohammed Khair E. A. Al-Shwaiyat

    2014-12-01

    Full Text Available New approach has been proposed for the simultaneous determination of two reducing agents based on the dependence of their reaction rate with 18-molybdo-2-phosphate heteropoly complex on pH. The method was automated using the manifold typical for the sequential analysis method. Ascorbic acid and rutin were determined by successive injection of two samples acidified to different pH. The linear range for rutin determination was 0.6-20 mg/L and the detection limit was 0.2 mg/L (l = 1 cm. The determination of rutin was possible in the presence of up to a 20-fold excess of ascorbic acid. The method was successfully applied to the determination of ascorbic acid and rutin in ascorutin tablets. The applicability of the proposed method for the determination of total polyphenol content in natural plant samples was shown.

  19. Sequential capillary electrophoresis analysis using optically gated sample injection and UV/vis detection.

    Science.gov (United States)

    Liu, Xiaoxia; Tian, Miaomiao; Camara, Mohamed Amara; Guo, Liping; Yang, Li

    2015-10-01

    We present sequential CE analysis of amino acids and L-asparaginase-catalyzed enzyme reaction, by combing the on-line derivatization, optically gated (OG) injection and commercial-available UV-Vis detection. Various experimental conditions for sequential OG-UV/vis CE analysis were investigated and optimized by analyzing a standard mixture of amino acids. High reproducibility of the sequential CE analysis was demonstrated with RSD values (n = 20) of 2.23, 2.57, and 0.70% for peak heights, peak areas, and migration times, respectively, and the LOD of 5.0 μM (for asparagine) and 2.0 μM (for aspartic acid) were obtained. With the application of the OG-UV/vis CE analysis, sequential online CE enzyme assay of L-asparaginase-catalyzed enzyme reaction was carried out by automatically and continuously monitoring the substrate consumption and the product formation every 12 s from the beginning to the end of the reaction. The Michaelis constants for the reaction were obtained and were found to be in good agreement with the results of traditional off-line enzyme assays. The study demonstrated the feasibility and reliability of integrating the OG injection with UV/vis detection for sequential online CE analysis, which could be of potential value for online monitoring various chemical reaction and bioprocesses. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. A new microcolumn-type microchip for examining the expression of chimeric fusion genes using a nucleic acid sandwich hybridization technique.

    Science.gov (United States)

    Ohnishi, Michihiro; Sasaki, Naoyuki; Kishimoto, Takuya; Watanabe, Hidetoshi; Takagi, Masatoshi; Mizutani, Shuki; Kishii, Noriyuki; Yasuda, Akio

    2014-11-01

    We report a new type of microcolumn installed in a microchip. The architecture allows use of a nucleic acid sandwich hybridization technique to detect a messenger RNA (mRNA) chain as a target. Data are presented that demonstrate that the expression of a chimeric fusion gene can be detected. The microcolumn was filled with semi-transparent microbeads made of agarose gel that acted as carriers, allowing increased efficiency of the optical detection of fluorescence from the microcolumn. The hybrid between the target trapped on the microbeads and a probe DNA labeled with a fluorescent dye was detected by measuring the intensity of the fluorescence from the microcolumn directly. These results demonstrate an easy and simple method for determining the expression of chimeric fusion genes with no preamplification. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Design of LabVIEW®-based software for the control of sequential injection analysis instrumentation for the determination of morphine

    Science.gov (United States)

    Lenehan, Claire E.; Lewis, Simon W.

    2002-01-01

    LabVIEW®-based software for the automation of a sequential injection analysis instrument for the determination of morphine is presented. Detection was based on its chemiluminescence reaction with acidic potassium permanganate in the presence of sodium polyphosphate. The calibration function approximated linearity (range 5 × 10-10 to 5 × 10-6 M) with a line of best fit of y=1.05x+8.9164 (R2 =0.9959), where y is the log10 signal (mV) and x is the log10 morphine concentration (M). Precision, as measured by relative standard deviation, was 0.7% for five replicate analyses of morphine standard (5 × 10-8 M). The limit of detection (3σ) was determined as 5 × 10-11 M morphine. PMID:18924729

  2. Design of LabVIEW-based software for the control of sequential injection analysis instrumentation for the determination of morphine.

    Science.gov (United States)

    Lenehan, Claire E; Barnett, Neil W; Lewis, Simon W

    2002-01-01

    LabVIEW-based software for the automation of a sequential injection analysis instrument for the determination of morphine is presented. Detection was based on its chemiluminescence reaction with acidic potassium permanganate in the presence of sodium polyphosphate. The calibration function approximated linearity (range 5 x 10(-10) to 5 x 10(-6) M) with a line of best fit of y=1.05(x)+8.9164 (R(2) =0.9959), where y is the log10 signal (mV) and x is the log10 morphine concentration (M). Precision, as measured by relative standard deviation, was 0.7% for five replicate analyses of morphine standard (5 x 10(-8) M). The limit of detection (3sigma) was determined as 5 x 10(-11) M morphine.

  3. On-line monitoring of Glucose and penicillin by sequential injection analysis

    DEFF Research Database (Denmark)

    Min, R.W.; Nielsen, Jens Bredal; Villadsen, John

    1996-01-01

    and a detector. The glucose analyzer is based on an enzymatic reaction using glucose oxidase, which converts glucose to glucono-lactone with formation of hydrogen peroxide and subsequent detection of H2O2 by a chemiluminescence reaction involving luminol. The penicillin analysis is based on formation......A sequential injection analysis (SIA) system has been developed for on-line monitoring of glucose and penicillin during cultivations of the filamentous fungus Penicillium chrysogenum. The SIA system consists of a peristaltic pump, an injection valve, two piston pumps, two multi-position valves...

  4. Determination of the sulfur mustard hydrolysis product thiodiglycol by microcolumn liquid chromatography coupled on-line with sulfur flame photometric detection using large-volume injections and peak

    NARCIS (Netherlands)

    Hooijschuur, E.W.J.; Kientz, C.E.; Brinkman, U.A.T.

    1999-01-01

    A selective, direct and relatively rapid method has been developed for the determination of thiodiglycol (TDG) in aqueous samples. TDG is the main hydrolysis product of the chemical warfare agent sulfur mustard. The method of analysis is based on the on-line coupling of reversed-phase microcolumn

  5. Automated injection of a radioactive sample for preparative HPLC with feedback control

    International Nuclear Information System (INIS)

    Iwata, Ren; Yamazaki, Shigeki

    1990-01-01

    The injection of a radioactive reaction mixture into a preparative HPLC column has been automated with computer control for rapid purification of routinely prepared positron emitting radiopharmaceuticals. Using pneumatic valves, a motor-driven pump and a liquid level sensor, two intelligent injection methods for the automation were compared with regard to efficient and rapid sample loading into a 2 mL loop of the 6-way valve. One, a precise but rather slow method, was demonstrated to be suitable for purification of 18 F-radiopharmaceuticals, while the other, due to its rapid operation, was more suitable for 11 C-radiopharmaceuticals. A sample volume of approx 0.5 mL can be injected onto a preparative HPLC column with over 90% efficiency with the present automated system. (author)

  6. Flow Injection/Sequential Injection Analysis Systems: Potential Use as Tools for Rapid Liver Diseases Biomarker Study

    Directory of Open Access Journals (Sweden)

    Supaporn Kradtap Hartwell

    2012-01-01

    Full Text Available Flow injection/sequential injection analysis (FIA/SIA systems are suitable for carrying out automatic wet chemical/biochemical reactions with reduced volume and time consumption. Various parts of the system such as pump, valve, and reactor may be built or adapted from available materials. Therefore the systems can be at lower cost as compared to other instrumentation-based analysis systems. Their applications for determination of biomarkers for liver diseases have been demonstrated in various formats of operation but only a few and limited types of biomarkers have been used as model analytes. This paper summarizes these applications for different types of reactions as a guide for using flow-based systems in more biomarker and/or multibiomarker studies.

  7. Exploiting flow injection and sequential injection for trace metal determinations in conjunction with detection by electrothermal atomic absorption spectrometry and inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    and selectivity. Either in order to separate/preconcentrate the analyte material, or because of the presence of potentially interfering matrix constituents. Such pretreatments are advantageously performed in flow injection (FI) or sequential injection (SI) manifolds, where all appropriate unit operations can...

  8. Q Sepharose micro-column chromatography: A simple screening method for identifying beta thalassemia traits and hemoglobin E carriers.

    Science.gov (United States)

    Wong, Peerapon; Sritippayawan, Suchila; Suwannakhon, Narutchala; Tapprom, Akamon; Deoisares, Rawisut; Sanguansermsri, Torpong

    2016-11-01

    For beta thalassemia control program in pregnancy, mass screening of the carrier state by determination of the hemoglobin (Hb) A 2 and Hb E proportions and mutation analysis is a preferred method for making prenatal diagnoses. Q Sepharose micro-column chromatography, developed for the determination of Hb A 2 and Hb E for screening purposes, was compared with high performance liquid chromatography (HPLC) to ascertain its relative accuracy and reliability. Results using Q Sepharose micro-column chromatography in 350 blood specimens, including 50 samples genetically proven to be beta thalassemia heterozygotes, were compared to HPLC for validation. An additional study was conducted to test a clinical application on a large-scale survey for beta thalassemia in 1581 pregnant women and their spouses. The mean (±SD) Hb A 2 proportions in the normal and genetically proven beta thalassemia heterozygotes were 2.70±0.40% and 6.30±1.23%, respectively, as determined by Q-Sepharose micro-column chromatography, and 2.65±0.31% and 5.37±0.96%, respectively, as determined by HPLC. The mean Hb E proportions in the Hb E heterozygotes were 23.25±4.13% and 24.72±3.5% as determined by Q Sepharose micro-column chromatography and HPLC, respectively. In the large-scale survey for beta thalassemia, 23 at risk couples were detected. Seven affected fetuses were identified by prenatal diagnosis. Q Sepharose micro-column chromatography was found to be reliable, reproducible and well-suited for large-scale surveys. Additionally, by being reusable and convenient, this simple and economical chromatography method may be an alternative means to screen for beta thalassemia and Hb E carriers in the mass population. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  9. Microcolumn high pressure liquid chromatography with a glass-frit nebulizer interface for plasma emission detection

    International Nuclear Information System (INIS)

    Ibrahim, M.; Nisamaneepong, W.; Caruso, J.

    1985-01-01

    Microcolumn high pressure liquid chromatography (micro-HPLC) is rapidly gaining recognition as a practical separation tool for organometallic compounds. The use of the inductively coupled plasma (ICP) as a detector for micro-HPLC is studied. Several miniaturized glass-frit nebulizers are investigated as interfaces between the output of the microbore column and the ICP torch. Their performance with aqueous and methanolic solutions is evaluated by direct nebulization and flow injection analysis. The most efficient of these nebulizers is used in the micro-HPLC/ICP study of some Cd, Pb, and Zn organometallic compounds. Detection limits of 1.92 ng of Pb for tetramethyllead and 5.01 ng of Pb for tetraethyllead are obtained and compared with regular HPLC/ICP of these same compounds. Approximately equivalent detection limits were obtained when using a microwave induced plasma as an alternate plasma source

  10. Sequential injection system incorporating a micro extraction column for automatic fractionation of metal ions in solid samples

    DEFF Research Database (Denmark)

    Chomchoei, Roongrat; Miró, Manuel; Hansen, Elo Harald

    2005-01-01

    as to the kinetics of the leaching processes and chemical associations in different soil geological phases. Special attention is also paid to the potentials of the microcolumn flowing technique for automatic processing of solid materials with variable homogeneity, as demonstrated with the sewage amended CRM483 soil...

  11. Evaluation of a novel PTFE material for separation and preconcentration of trace levels of metal ions in sequential injection (SI) and sequential injection lab-on-valve (SI-LOV) systems interfaced with detection by ETAAS

    DEFF Research Database (Denmark)

    Long, Xiangbao; Chomchoei, Roongrat; Gała, Piotr

    The operational characteristics of a novel PTFE bead material, granular Algoflon®, used for separation and preconcentration of metal ions via adsorption of on-line generated non-charged metal complexes, were evaluated in a sequential injection (SI) system furnished with an external packed column...... and in a sequential injection lab-on-valve (SI-LOV) system. Employed for the determination of cadmium(II), complexed with diethyldithiophosphate (DDPA), and detection by electrothermal atomic absorption spectrometry (ETAAS), its performance was compared to that of a previously used material, Aldrich PTFE, which had...... demonstrated that PTFE was the most promising for solid-state pretreatments. By comparing the two materials, the Algoflon® beads exhibited much higher sensitivity (1.6107 versus 0.2956 μg l-1 per integrated absorbance (s)), and better retention efficiency (82% versus 74%) and enrichment factor (20.8 versus 17...

  12. Commix: Automating Evaluation and Exploitation of Command Injection Vulnerabilities in Web Applications

    OpenAIRE

    Stasinopoulos, Anastasios; Ntantogian, Christoforos; Xenakis, Christos

    2018-01-01

    Despite the prevalence and the high impact of command injection attacks, little attention has been given by the research community to this type of code injections. Although there are many software tools to detect and exploit other types of code injections, such as SQL injections or Cross Site Scripting, there is no dedicated and specialized software that detects and exploits, automatically, command injection vulnerabilities. This paper proposes an open source tool that automates the process o...

  13. Analysis of drug-protein binding using on-line immunoextraction and high-performance affinity microcolumns: Studies with normal and glycated human serum albumin.

    Science.gov (United States)

    Matsuda, Ryan; Jobe, Donald; Beyersdorf, Jared; Hage, David S

    2015-10-16

    A method combining on-line immunoextraction microcolumns with high-performance affinity chromatography (HPAC) was developed and tested for use in examining drug-protein interactions with normal or modified proteins. Normal human serum albumin (HSA) and glycated HSA were used as model proteins for this work. High-performance immunoextraction microcolumns with sizes of 1.0-2.0 cm × 2.1mm i.d. and containing anti-HSA polyclonal antibodies were developed and tested for their ability to bind normal HSA or glycated HSA. These microcolumns were able to extract up to 82-93% for either type of protein at 0.05-0.10 mL/min and had a binding capacity of 0.34-0.42 nmol HSA for a 1.0 cm × 2.1mm i.d. microcolumn. The immunoextraction microcolumns and their adsorbed proteins were tested for use in various approaches for drug binding studies. Frontal analysis was used with the adsorbed HSA/glycated HSA to measure the overall affinities of these proteins for the drugs warfarin and gliclazide, giving comparable values to those obtained previously using similar protein preparations that had been covalently immobilized within HPAC columns. Zonal elution competition studies with gliclazide were next performed to examine the specific interactions of this drug at Sudlow sites I and II of the adsorbed proteins. These results were also comparable to those noted in prior work with covalently immobilized samples of normal HSA or glycated HSA. These experiments indicated that drug-protein binding studies can be carried out by using on-line immunoextraction microcolumns with HPAC. The same method could be used in the future with clinical samples and other drugs or proteins of interest in pharmaceutical studies or biomedical research. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Sequential injection analysis for automation of the Winkler methodology, with real-time SIMPLEX optimization and shipboard application

    Energy Technology Data Exchange (ETDEWEB)

    Horstkotte, Burkhard; Tovar Sanchez, Antonio; Duarte, Carlos M. [Department of Global Change Research, IMEDEA (CSIC-UIB) Institut Mediterrani d' Estudis Avancats, Miquel Marques 21, 07190 Esporles (Spain); Cerda, Victor, E-mail: Victor.Cerda@uib.es [University of the Balearic Islands, Department of Chemistry Carreterra de Valldemossa km 7.5, 07011 Palma de Mallorca (Spain)

    2010-01-25

    A multipurpose analyzer system based on sequential injection analysis (SIA) for the determination of dissolved oxygen (DO) in seawater is presented. Three operation modes were established and successfully applied onboard during a research cruise in the Southern ocean: 1st, in-line execution of the entire Winkler method including precipitation of manganese (II) hydroxide, fixation of DO, precipitate dissolution by confluent acidification, and spectrophotometric quantification of the generated iodine/tri-iodide (I{sub 2}/I{sub 3}{sup -}), 2nd, spectrophotometric quantification of I{sub 2}/I{sub 3}{sup -} in samples prepared according the classical Winkler protocol, and 3rd, accurate batch-wise titration of I{sub 2}/I{sub 3}{sup -} with thiosulfate using one syringe pump of the analyzer as automatic burette. In the first mode, the zone stacking principle was applied to achieve high dispersion of the reagent solutions in the sample zone. Spectrophotometric detection was done at the isobestic wavelength 466 nm of I{sub 2}/I{sub 3}{sup -}. Highly reduced consumption of reagents and sample compared to the classical Winkler protocol, linear response up to 16 mg L{sup -1} DO, and an injection frequency of 30 per hour were achieved. It is noteworthy that for the offline protocol, sample metering and quantification with a potentiometric titrator lasts in general over 5 min without counting sample fixation, incubation, and glassware cleaning. The modified SIMPLEX methodology was used for the simultaneous optimization of four volumetric and two chemical variables. Vertex calculation and consequent application including in-line preparation of one reagent was carried out in real-time using the software AutoAnalysis. The analytical system featured high signal stability, robustness, and a repeatability of 3% RSD (1st mode) and 0.8% (2nd mode) during shipboard application.

  15. Sequential injection analysis for automation of the Winkler methodology, with real-time SIMPLEX optimization and shipboard application

    International Nuclear Information System (INIS)

    Horstkotte, Burkhard; Tovar Sanchez, Antonio; Duarte, Carlos M.; Cerda, Victor

    2010-01-01

    A multipurpose analyzer system based on sequential injection analysis (SIA) for the determination of dissolved oxygen (DO) in seawater is presented. Three operation modes were established and successfully applied onboard during a research cruise in the Southern ocean: 1st, in-line execution of the entire Winkler method including precipitation of manganese (II) hydroxide, fixation of DO, precipitate dissolution by confluent acidification, and spectrophotometric quantification of the generated iodine/tri-iodide (I 2 /I 3 - ), 2nd, spectrophotometric quantification of I 2 /I 3 - in samples prepared according the classical Winkler protocol, and 3rd, accurate batch-wise titration of I 2 /I 3 - with thiosulfate using one syringe pump of the analyzer as automatic burette. In the first mode, the zone stacking principle was applied to achieve high dispersion of the reagent solutions in the sample zone. Spectrophotometric detection was done at the isobestic wavelength 466 nm of I 2 /I 3 - . Highly reduced consumption of reagents and sample compared to the classical Winkler protocol, linear response up to 16 mg L -1 DO, and an injection frequency of 30 per hour were achieved. It is noteworthy that for the offline protocol, sample metering and quantification with a potentiometric titrator lasts in general over 5 min without counting sample fixation, incubation, and glassware cleaning. The modified SIMPLEX methodology was used for the simultaneous optimization of four volumetric and two chemical variables. Vertex calculation and consequent application including in-line preparation of one reagent was carried out in real-time using the software AutoAnalysis. The analytical system featured high signal stability, robustness, and a repeatability of 3% RSD (1st mode) and 0.8% (2nd mode) during shipboard application.

  16. Sub-1min separation in sequential injection chromatography for determination of synthetic water-soluble dyes in pharmaceutical formulation.

    Science.gov (United States)

    Davletbaeva, Polina; Chocholouš, Petr; Bulatov, Andrey; Šatínský, Dalibor; Solich, Petr

    2017-09-05

    Sequential Injection Chromatography (SIC) evolved from fast and automated non-separation Sequential Injection Analysis (SIA) into chromatographic separation method for multi-element analysis. However, the speed of the measurement (sample throughput) is due to chromatography significantly reduced. In this paper, a sub-1min separation using medium polar cyano monolithic column (5mm×4.6mm) resulted in fast and green separation with sample throughput comparable with non-separation flow methods The separation of three synthetic water-soluble dyes (sunset yellow FCF, carmoisine and green S) was in a gradient elution mode (0.02% ammonium acetate, pH 6.7 - water) with flow rate of 3.0mLmin -1 corresponding with sample throughput of 30h -1 . Spectrophotometric detection wavelengths were set to 480, 516 and 630nm and 10Hz data collection rate. The performance of the separation was described and discussed (peak capacities 3.48-7.67, peak symmetries 1.72-1.84 and resolutions 1.42-1.88). The method was represented by validation parameters: LODs of 0.15-0.35mgL -1 , LOQs of 0.50-1.25mgL -1 , calibration ranges 0.50-150.00mgL -1 (r>0.998) and repeatability at 10.0mgL -1 of RSD≤0.98% (n=6). The method was used for determination of the dyes in "forest berries" colored pharmaceutical cough-cold formulation. The sample matrix - pharmaceuticals and excipients were not interfering with vis determination because of no retention in the separation column and colorless nature. The results proved the concept of fast and green chromatography approach using very short medium polar monolithic column in SIC. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Solid reactors in sequential injection analysis: Recent trends in the environmental field

    DEFF Research Database (Denmark)

    Miró, Manuel; Hansen, Elo Harald

    2006-01-01

    -bead injection (SI-BI), used in either the jet-ring or lab-on-valve configurations, is presented as a front-end to many detectors. This article also outlines recent trends focused on exploiting SI as an automated tool for handling solid samples of environmental concern and accommodating dynamic fractionation...

  18. Rapid Determination of Plutonium Isotopes in Environmental Samples Using Sequential Injection Extraction Chromatography and Detection by Inductively Coupled Plasma Mass Spectrometry

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per

    2009-01-01

    This article presents an automated method for the rapid determination of 239Pu and 240Pu in various environmental samples. The analytical method involves the in-line separation of Pu isotopes using extraction chromatography (TEVA) implemented in a sequential injection (SI) network followed...... by detection of isolated analytes with inductively coupled plasma mass spectrometry (ICP-MS). The method has been devised for the determination of Pu isotopes at environmentally relevant concentrations, whereby it has been successfully applied to the analyses of large volumes/amounts of samples, for example......, 100−200 g of soil and sediment, 20 g of seaweed, and 200 L of seawater following analyte preconcentration. The investigation of the separation capability of the assembled SI system revealed that up to 200 g of soil or sediment can be treated using a column containing about 0.70 g of TEVA resin...

  19. Stability of inorganic mercury and methylmercury on yeast-silica gel microcolumns: field sampling capabilities

    Energy Technology Data Exchange (ETDEWEB)

    Perez-Corona, M. [Universidad Complutense de Madrid (Spain). Dept. de Quimica Analitica

    2000-11-01

    The stability of methylmercury and inorganic mercury retained on yeast-silica gel microcolumns was established and compared with the stability of these species in solution. Yeast-silica gel columns with the retained analytes were stored for two months at three different temperatures: -20 C, 4 C and room temperature. At regular time intervals, both mercury species were eluted and quantified by cold vapor atomic absorption spectrometry (CVAAS). Methylmercury was found stable in the columns over the two-month period at the three different temperatures tested while the concentration of inorganic mercury decreased after one week's storage even at -20 C. These results are of great interest since the use of these microcolumns allows the preconcentration and storage of mercury species until analysis, thus saving laboratory space and avoiding the problems associated with maintaining species integrity in aqueous solution. (orig.)

  20. On-line sequential injection-capillary electrophoresis for near-real-time monitoring of extracellular lactate in cell culture flasks.

    Science.gov (United States)

    Alhusban, Ala A; Gaudry, Adam J; Breadmore, Michael C; Gueven, Nuri; Guijt, Rosanne M

    2014-01-03

    Cell culture has replaced many in vivo studies because of ethical and regulatory measures as well as the possibility of increased throughput. Analytical assays to determine (bio)chemical changes are often based on end-point measurements rather than on a series of sequential determinations. The purpose of this work is to develop an analytical system for monitoring cell culture based on sequential injection-capillary electrophoresis (SI-CE) with capacitively coupled contactless conductivity detection (C(4)D). The system was applied for monitoring lactate production, an important metabolic indicator, during mammalian cell culture. Using a background electrolyte consisting of 25mM tris(hydroxymethyl)aminomethane, 35mM cyclohexyl-2-aminoethanesulfonic acid with 0.02% poly(ethyleneimine) (PEI) at pH 8.65 and a multilayer polymer coated capillary, lactate could be resolved from other compounds present in media with relative standard deviations 0.07% for intraday electrophoretic mobility and an analysis time of less than 10min. Using the human embryonic kidney cell line HEK293, lactate concentrations in the cell culture medium were measured every 20min over 3 days, requiring only 8.73μL of sample per run. Combining simplicity, portability, automation, high sample throughput, low limits of detection, low sample consumption and the ability to up- and outscale, this new methodology represents a promising technique for near real-time monitoring of chemical changes in diverse cell culture applications. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Rapid and simultaneous determination of neptunium and plutonium isotopes in environmental samples by extraction chromatography using sequential injection analysis and ICP-MS

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per

    2010-01-01

    plutonium and neptunium in three reference materials were in agreement with the recommended or literature values at the 0.05 significance level. The developed method is suitable for the analysis of up to 10 g of soil and 20 g of seaweed samples. The extraction chromatographic separation within the SI system......This paper reports an automated analytical method for rapid and simultaneous determination of plutonium isotopes (239Pu and 240Pu) and neptunium (237Np) in environmental samples. An extraction chromatographic column packed with TrisKem TEVA® resin was incorporated in a sequential injection (SI...... for a single sample takes less than 1.5 h. As compared to batchwise procedures, the developed method significantly improves the analysis efficiency, reduces the labor intensity and expedites the simultaneous determination of plutonium and neptunium as demanded in emergency actions....

  2. Highly selective micro-sequential injection lab-on-valve (muSI-LOV) method for the determination of ultra-trace concentrations of nickel in saline matrices using detection by electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Long, Xiangbao; Miró, Manuel; Jensen, Rikard; Hansen, Elo Harald

    2006-10-01

    A highly selective procedure is proposed for the determination of ultra-trace level concentrations of nickel in saline aqueous matrices exploiting a micro-sequential injection Lab-On-Valve (muSI-LOV) sample pretreatment protocol comprising bead injection separation/pre-concentration and detection by electrothermal atomic absorption spectrometry (ETAAS). Based on the dimethylglyoxime (DMG) reaction used for nickel analysis, the sample, as contained in a pH 9.0 buffer, is, after on-line merging with the chelating reagent, transported to a reaction coil attached to one of the external ports of the LOV to assure sufficient reaction time for the formation of Ni(DMG)(2) chelate. The non-ionic coordination compound is then collected in a renewable micro-column packed with a reversed-phase copolymeric sorbent [namely, poly(divinylbenzene-co-N-vinylpyrrolidone)] containing a balanced ratio of hydrophilic and lipophilic monomers. Following elution by a 50-muL methanol plug in an air-segmented modality, the nickel is finally quantified by ETAAS. Under the optimized conditions and for a sample volume of 1.8 mL, a retention efficiency of 70 % and an enrichment factor of 25 were obtained. The proposed methodology showed a high tolerance to the commonly encountered alkaline earth matrix elements in environmental waters, that is, calcium and magnesium, and was successfully applied for the determination of nickel in an NIST standard reference material (NIST 1640-Trace elements in natural water), household tap water of high hardness and local seawater. Satisfying recoveries were achieved for all spiked environmental water samples with maximum deviations of 6 %. The experimental results for the standard reference material were not statistically different to the certified value at a significance level of 0.05.

  3. Arsenic fractionation in agricultural soil using an automated three-step sequential extraction method coupled to hydride generation-atomic fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Rosas-Castor, J.M. [Universidad Autónoma de Nuevo León, UANL, Facultad de Ciencias Químicas, Cd. Universitaria, San Nicolás de los Garza, Nuevo León, C.P. 66451 Nuevo León (Mexico); Group of Analytical Chemistry, Automation and Environment, University of Balearic Islands, Cra. Valldemossa km 7.5, 07122 Palma de Mallorca (Spain); Portugal, L.; Ferrer, L. [Group of Analytical Chemistry, Automation and Environment, University of Balearic Islands, Cra. Valldemossa km 7.5, 07122 Palma de Mallorca (Spain); Guzmán-Mar, J.L.; Hernández-Ramírez, A. [Universidad Autónoma de Nuevo León, UANL, Facultad de Ciencias Químicas, Cd. Universitaria, San Nicolás de los Garza, Nuevo León, C.P. 66451 Nuevo León (Mexico); Cerdà, V. [Group of Analytical Chemistry, Automation and Environment, University of Balearic Islands, Cra. Valldemossa km 7.5, 07122 Palma de Mallorca (Spain); Hinojosa-Reyes, L., E-mail: laura.hinojosary@uanl.edu.mx [Universidad Autónoma de Nuevo León, UANL, Facultad de Ciencias Químicas, Cd. Universitaria, San Nicolás de los Garza, Nuevo León, C.P. 66451 Nuevo León (Mexico)

    2015-05-18

    Highlights: • A fully automated flow-based modified-BCR extraction method was developed to evaluate the extractable As of soil. • The MSFIA–HG-AFS system included an UV photo-oxidation step for organic species degradation. • The accuracy and precision of the proposed method were found satisfactory. • The time analysis can be reduced up to eight times by using the proposed flow-based BCR method. • The labile As (F1 + F2) was <50% of total As in soil samples from As-contaminated-mining zones. - Abstract: A fully automated modified three-step BCR flow-through sequential extraction method was developed for the fractionation of the arsenic (As) content from agricultural soil based on a multi-syringe flow injection analysis (MSFIA) system coupled to hydride generation-atomic fluorescence spectrometry (HG-AFS). Critical parameters that affect the performance of the automated system were optimized by exploiting a multivariate approach using a Doehlert design. The validation of the flow-based modified-BCR method was carried out by comparison with the conventional BCR method. Thus, the total As content was determined in the following three fractions: fraction 1 (F1), the acid-soluble or interchangeable fraction; fraction 2 (F2), the reducible fraction; and fraction 3 (F3), the oxidizable fraction. The limits of detection (LOD) were 4.0, 3.4, and 23.6 μg L{sup −1} for F1, F2, and F3, respectively. A wide working concentration range was obtained for the analysis of each fraction, i.e., 0.013–0.800, 0.011–0.900 and 0.079–1.400 mg L{sup −1} for F1, F2, and F3, respectively. The precision of the automated MSFIA–HG-AFS system, expressed as the relative standard deviation (RSD), was evaluated for a 200 μg L{sup −1} As standard solution, and RSD values between 5 and 8% were achieved for the three BCR fractions. The new modified three-step BCR flow-based sequential extraction method was satisfactorily applied for arsenic fractionation in real agricultural

  4. Safety assessment of automated vehicle functions by simulation-based fault injection

    OpenAIRE

    Juez, Garazi; Amparan, Estibaliz; Lattarulo, Ray; Rastelli, Joshue Perez; Ruiz, Alejandra; Espinoza, Huascar

    2017-01-01

    As automated driving vehicles become more sophisticated and pervasive, it is increasingly important to assure its safety even in the presence of faults. This paper presents a simulation-based fault injection approach (Sabotage) aimed at assessing the safety of automated vehicle functions. In particular, we focus on a case study to forecast fault effects during the model-based design of a lateral control function. The goal is to determine the acceptable fault detection interval for pe...

  5. Sensors and Automated Analyzers for Radionuclides

    International Nuclear Information System (INIS)

    Grate, Jay W.; Egorov, Oleg B.

    2003-01-01

    The production of nuclear weapons materials has generated large quantities of nuclear waste and significant environmental contamination. We have developed new, rapid, automated methods for determination of radionuclides using sequential injection methodologies to automate extraction chromatographic separations, with on-line flow-through scintillation counting for real time detection. This work has progressed in two main areas: radionuclide sensors for water monitoring and automated radiochemical analyzers for monitoring nuclear waste processing operations. Radionuclide sensors have been developed that collect and concentrate radionuclides in preconcentrating minicolumns with dual functionality: chemical selectivity for radionuclide capture and scintillation for signal output. These sensors can detect pertechnetate to below regulatory levels and have been engineered into a prototype for field testing. A fully automated process monitor has been developed for total technetium in nuclear waste streams. This instrument performs sample acidification, speciation adjustment, separation and detection in fifteen minutes or less

  6. Sequential injection/bead injection lab-on-valve schemes for on-line solid phase extraction and preconcentration of ultra-trace levels of heavy metals with determination by ETAAS and ICPMS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald; Miró, Manuel

    2003-01-01

    are focused on the applications of SI-BI-LOV protocols for on-line microcolumn based solid phase extraction of ultra-trace levels of heavy metals, employing the so-called renewable surface separation and preconcentration manipulatory scheme. Two types of sorbents have been employed as packing material...

  7. Nanophotonic production, modulation and switching of ions by silicon microcolumn arrays

    Science.gov (United States)

    Vertes, Akos; Walker, Bennett N.

    2013-09-10

    The production and use of silicon microcolumn arrays that harvest light from a laser pulse to produce ions are described. The systems of the present invention seem to behave like a quasi-periodic antenna array with ion yields that show profound dependence on the plane of laser light polarization and the angle of incidence. By providing photonic ion sources, this enables enhanced control of ion production on a micro/nano scale and direct integration with miniaturized analytical devices.

  8. Rapid isolation of plutonium in environmental solid samples using sequential injection anion exchange chromatography followed by detection with inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Qiao Jixin, E-mail: jixin.qiao@risoe.d [Radiation Research Division, Riso National Laboratory for Sustainable Energy, Technical University of Denmark, DK-4000 Roskilde (Denmark); Hou Xiaolin; Roos, Per [Radiation Research Division, Riso National Laboratory for Sustainable Energy, Technical University of Denmark, DK-4000 Roskilde (Denmark); Miro, Manuel [Department of Chemistry, Faculty of Sciences, University of the Balearic Islands, Carretera de Valldemossa km. 7.5, E-07122 Palma de Mallorca, Illes Balears (Spain)

    2011-01-31

    This paper reports an automated analytical method for rapid determination of plutonium isotopes ({sup 239}Pu and {sup 240}Pu) in environmental solid extracts. Anion exchange chromatographic columns were incorporated in a sequential injection (SI) system to undertake the automated separation of plutonium from matrix and interfering elements. The analytical results most distinctly demonstrated that the crosslinkage of the anion exchanger is a key parameter controlling the separation efficiency. AG 1-x4 type resin was selected as the most suitable sorbent material for analyte separation. Investigation of column size effect upon the separation efficiency revealed that small-sized (2 mL) columns sufficed to handle up to 50 g of environmental soil samples. Under the optimum conditions, chemical yields of plutonium exceeded 90% and the decontamination factors for uranium, thorium and lead ranged from 10{sup 3} to 10{sup 4}. The determination of plutonium isotopes in three standard/certified reference materials (IAEA-375 soil, IAEA-135 sediment and NIST-4359 seaweed) and two reference samples (Irish Sea sediment and Danish soil) revealed a good agreement with reference/certified values. The SI column-separation method is straightforward and less labor intensive as compared with batch-wise anion exchange chromatographic procedures. Besides, the automated method features low consumption of ion-exchanger and reagents for column washing and elution, with the consequent decrease in the generation of acidic waste, thus bearing green chemical credentials.

  9. Determination of trace lithium in uranium compounds by adsorption on activated alumina using a micro-column method.

    Science.gov (United States)

    Luo, Ming-Biao; Li, Bo-Ping; Yang, Zhi; Liu, Wei; Sun, Yu-Zhen

    2008-08-01

    A novel method using a micro-column packed with active alumina as solid phase was proposed for separation of trace lithium from uranium compounds prior to determination. The method is based on a preliminary chromatographic separation of the total amount of uranium. This separation involves passing the solution containing sodium carbonate through active alumina and then eluting the trace lithium retained by the solid phase with a solution of sulfuric acid. Two modes, off-line and on-line micro-column preconcentration, were performed. In conjunction with atomic absorption spectrometry, this on-line preconcentration technique allows a determination of lithium at 10(-9) level. Both off-line and on-line mode operation conditions were investigated in separation and determination of trace lithium by micro-column method (length of column bed, flow rate, etc.). The adsorption capacity of activated alumina was found to be 343 microg g(-1) for lithium. Under the optimal operation condition, the detection limit (DL) of on-line preconcentration corresponding to three times the standard deviation of the blank (S/N = 3) was found to be 1.3 ng mL(-1) and the RSD of this method is 3.32% (n = 5). The on-line calibration graph was linear over the range 20 - 200 ng mL(-1). A good preconcentration factor 820 was achieved by experiment under the on-line mode. The developed method was applied to the analysis of trace lithium in nuclear grade uranium compounds.

  10. A LabVIEW®-based software for the control of the AUTORAD platform. A fully automated multisequential flow injection analysis Lab-on-Valve (MSFIA-LOV) system for radiochemical analysis

    International Nuclear Information System (INIS)

    Barbesi, Donato; Vilas, Victor Vicente; Millet, Sylvain; Sandow, Miguel; Colle, Jean-Yves; Heras, Laura Aldave de las

    2017-01-01

    A LabVIEW®-based software for the control of the fully automated multi-sequential flow injection analysis Lab-on-Valve (MSFIA-LOV) platform AutoRAD performing radiochemical analysis is described. The analytical platform interfaces an Arduino®-based device triggering multiple detectors providing a flexible and fit for purpose choice of detection systems. The different analytical devices are interfaced to the PC running LabVIEW®VI software using USB and RS232 interfaces, both for sending commands and receiving confirmation or error responses. The AUTORAD platform has been successfully applied for the chemical separation and determination of Sr, an important fission product pertinent to nuclear waste. (author)

  11. A LabVIEW®-based software for the control of the AUTORAD platform: a fully automated multisequential flow injection analysis Lab-on-Valve (MSFIA-LOV) system for radiochemical analysis.

    Science.gov (United States)

    Barbesi, Donato; Vicente Vilas, Víctor; Millet, Sylvain; Sandow, Miguel; Colle, Jean-Yves; Aldave de Las Heras, Laura

    2017-01-01

    A LabVIEW ® -based software for the control of the fully automated multi-sequential flow injection analysis Lab-on-Valve (MSFIA-LOV) platform AutoRAD performing radiochemical analysis is described. The analytical platform interfaces an Arduino ® -based device triggering multiple detectors providing a flexible and fit for purpose choice of detection systems. The different analytical devices are interfaced to the PC running LabVIEW ® VI software using USB and RS232 interfaces, both for sending commands and receiving confirmation or error responses. The AUTORAD platform has been successfully applied for the chemical separation and determination of Sr, an important fission product pertinent to nuclear waste.

  12. Exploring Liquid Sequential Injection Chromatography to Teach Fundamentals of Separation Methods: A Very Fast Analytical Chemistry Experiment

    Science.gov (United States)

    Penteado, Jose C.; Masini, Jorge Cesar

    2011-01-01

    Influence of the solvent strength determined by the addition of a mobile-phase organic modifier and pH on chromatographic separation of sorbic acid and vanillin has been investigated by the relatively new technique, liquid sequential injection chromatography (SIC). This technique uses reversed-phase monolithic stationary phase to execute fast…

  13. Effects of neostriatal 6-OHDA lesion on performance in a rat sequential reaction time task.

    Science.gov (United States)

    Domenger, D; Schwarting, R K W

    2008-10-31

    Work in humans and monkeys has provided evidence that the basal ganglia, and the neurotransmitter dopamine therein, play an important role for sequential learning and performance. Compared to primates, experimental work in rodents is rather sparse, largely due to the fact that tasks comparable to the human ones, especially serial reaction time tasks (SRTT), had been lacking until recently. We have developed a rat model of the SRTT, which allows to study neural correlates of sequential performance and motor sequence execution. Here, we report the effects of dopaminergic neostriatal lesions, performed using bilateral 6-hydroxydopamine injections, on performance of well-trained rats tested in our SRTT. Sequential behavior was measured in two ways: for one, the effects of small violations of otherwise well trained sequences were examined as a measure of attention and automation. Secondly, sequential versus random performance was compared as a measure of sequential learning. Neurochemically, the lesions led to sub-total dopamine depletions in the neostriatum, which ranged around 60% in the lateral, and around 40% in the medial neostriatum. These lesions led to a general instrumental impairment in terms of reduced speed (response latencies) and response rate, and these deficits were correlated with the degree of striatal dopamine loss. Furthermore, the violation test indicated that the lesion group conducted less automated responses. The comparison of random versus sequential responding showed that the lesion group did not retain its superior sequential performance in terms of speed, whereas they did in terms of accuracy. Also, rats with lesions did not improve further in overall performance as compared to pre-lesion values, whereas controls did. These results support previous results that neostriatal dopamine is involved in instrumental behaviour in general. Also, these lesions are not sufficient to completely abolish sequential performance, at least when acquired

  14. Laser desorption ionization and peptide sequencing on laser induced silicon microcolumn arrays

    Science.gov (United States)

    Vertes, Akos [Reston, VA; Chen, Yong [San Diego, CA

    2011-12-27

    The present invention provides a method of producing a laser-patterned silicon surface, especially silicon wafers for use in laser desorption ionization (LDI-MS) (including MALDI-MS and SELDI-MS), devices containing the same, and methods of testing samples employing the same. The surface is prepared by subjecting a silicon substrate to multiple laser shots from a high-power picosecond or femtosecond laser while in a processing environment, e.g., underwater, and generates a remarkable homogenous microcolumn array capable of providing an improved substrate for LDI-MS.

  15. Method development for the determination of arsenic by sequential injection/anodic stripping voltammetry using long-lasting gold-modified screen-printed carbon electrode.

    Science.gov (United States)

    Punrat, Eakkasit; Chuanuwatanakul, Suchada; Kaneta, Takashi; Motomizu, Shoji; Chailapakul, Orawon

    2013-11-15

    An automated method has been developed for determining the concentration of inorganic arsenic. The technique uses sequential injection/anodic stripping voltammetry with a long-lasting gold-modified screen-printed carbon electrode. The long-lasting gold electrode was electrochemically deposited onto a screen-printed carbon electrode at a potential of -0.5 V vs. Ag/AgCl in a supporting electrolyte solution of 1M hydrochloric acid. Under optimal conditions and the applied potentials, the electrode demonstrated that it can be used for a long time without a renewal process. The linear range for the determination of arsenic(III) was 1-100 μg L(-1), and the limit of detection (LOD) in standard solutions was as low as 0.03 μg L(-1) for a deposition time of 120 s and sample volume of 1 mL. This method was used to determine the concentration of arsenic(III) in water samples with satisfactory results. The LOD in real samples was found to be 0.5 μg L(-1). In addition, speciation between arsenic(III) and arsenic(V) has been achieved with the proposed method using deposition potentials of -0.5 V and -1.5 V for the determination of the arsenic(III) concentration and the total arsenic concentration, respectively; the results were acceptable. The proposed method is an automated system that offers a less expensive alternative for determining trace amounts of inorganic arsenic. © 2013 Elsevier B.V. All rights reserved.

  16. Micro-column plasma emission liquid chromatograph. [Patent application

    Science.gov (United States)

    Gay, D.D.

    1982-08-12

    In a direct current plasma emission spectrometer for use in combination with a microcolumn liquid chromatograph, an improved plasma source unit is claimed. The plasma source unit includes a quartz capillary tube having an inlet means, outlet off gas means and a pair of spaced electrodes defining a plasma region in the tube. The inlet means is connected to and adapted to receive eluant of the liquid chromatograph along with a stream of plasma-forming gas. There is an opening through the wall of the capillary tube penetrating into the plasma region. A soft glass capillary light pipe is disposed at the opening, is connected to the spectrometer, and is adapted to transmit light passing from the plasma region to the spectrometer. There is also a source of electromotive force connected to the electrodes sufficient to initiate and sustain a plasma in the plasma region of the tube.

  17. Evaluation of a novel PTFE material for use as a means for separation and preconcentration of trace levels of metal ions in sequential injection (SI) and sequential injection lab-on-valve (SI-LOV) systems. Determination of cadmium (II) with detection by electrothermal atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Long, Xiangbao; Chomchoei, Roongrat; Hansen, Elo Harald

    2004-01-01

    with an external packed column and in a sequential injection lab-on-valve (SI-LOV) system. Employed for the determination of cadmium(II), complexed with diethyldithiophosphate (DDPA), and detection by electrothermal atomic absorption spectrometry (ETAAS), its performance was compared to that of a previously used...

  18. An automated optofluidic biosensor platform combining interferometric sensors and injection moulded microfluidics.

    Science.gov (United States)

    Szydzik, C; Gavela, A F; Herranz, S; Roccisano, J; Knoerzer, M; Thurgood, P; Khoshmanesh, K; Mitchell, A; Lechuga, L M

    2017-08-08

    A primary limitation preventing practical implementation of photonic biosensors within point-of-care platforms is their integration with fluidic automation subsystems. For most diagnostic applications, photonic biosensors require complex fluid handling protocols; this is especially prominent in the case of competitive immunoassays, commonly used for detection of low-concentration, low-molecular weight biomarkers. For this reason, complex automated microfluidic systems are needed to realise the full point-of-care potential of photonic biosensors. To fulfil this requirement, we propose an on-chip valve-based microfluidic automation module, capable of automating such complex fluid handling. This module is realised through application of a PDMS injection moulding fabrication technique, recently described in our previous work, which enables practical fabrication of normally closed pneumatically actuated elastomeric valves. In this work, these valves are configured to achieve multiplexed reagent addressing for an on-chip diaphragm pump, providing the sample and reagent processing capabilities required for automation of cyclic competitive immunoassays. Application of this technique simplifies fabrication and introduces the potential for mass production, bringing point-of-care integration of complex automated microfluidics into the realm of practicality. This module is integrated with a highly sensitive, label-free bimodal waveguide photonic biosensor, and is demonstrated in the context of a proof-of-concept biosensing assay, detecting the low-molecular weight antibiotic tetracycline.

  19. Determination of picloram in natural waters employing sequential injection square wave voltammetry using the hanging mercury drop electrode.

    Science.gov (United States)

    Dos Santos, Luciana B O; Masini, Jorge C

    2007-05-15

    This paper describes the development of a sequential injection analysis method to automate the determination of picloram by square wave voltammetry exploiting the concept of monosegmented flow analysis to perform in-line sample conditioning and standard addition. To perform these tasks, an 800muL monosegment is formed, composed by 400muL of sample and 400muL of conditioning/standard solution, in medium of 0.10molL(-1) H(2)SO(4). Homogenization of the monosegment is achieved by three flow reversals. After homogenization the mixture zone is injected toward the flow cell, which is adapted to the capillary of a hanging drop mercury electrode, at a flow rate of 50muLs(-1). After a suitable delay time, the potential is scanned from -0.5 to -1.0V versus Ag/AgCl at frequency of 300Hz and pulse height of 25mV. The linear dynamic range is observed for picloram concentrations between 0.10 and 2.50mgL(-1) fitting to the linear equation I(p)=(-2.19+/-0.03)C(picloram)+(0.096+/-0.039), with R(2)=0.9996, for which the slope is given in muALmg(-1). The detection and quantification limits are 0.036 and 0.12mgL(-1), respectively. The sampling frequency is 37h(-1) when the standard addition protocol is followed, but can be increased to 41h(-1) if the protocol to obtain in-line external calibration curve is used for quantification. The method was applied for determination of picloram in spiked water samples and the accuracy was evaluated by comparison with high performance liquid chromatography using molecular absorption at 220nm for detection. No evidences of statistically significant differences between the two methods were observed.

  20. Sequential Injection Determination of D-Glucose by Chemiluminescence Using an Open Tubular Immobilised Enzyme Reactor

    DEFF Research Database (Denmark)

    Liu, Xuezhu; Hansen, Elo Harald

    1996-01-01

    A sequential injection analysis system is described that incorporates a nylon tubular reactor containing immobilised glucose oxidase, allowing determination of D-glucose by means of subsequent luminol chemiluminescence detection of the hydrogen peroxide generated in the enzymatic reaction....... The operating parameters were optimised by fractional factorial screening and response surface modelling. The linear range of D-glucose determination was 30-600 mu M, With a detection limit of 15 mu M using a photodiode detector. The sampling frequency was 54 h(-1). Lower LOD (0.5 mu M D-glucose) could...

  1. Experimental optimization of a direct injection homogeneous charge compression ignition gasoline engine using split injections with fully automated microgenetic algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Canakci, M. [Kocaeli Univ., Izmit (Turkey); Reitz, R.D. [Wisconsin Univ., Dept. of Mechanical Engineering, Madison, WI (United States)

    2003-03-01

    Homogeneous charge compression ignition (HCCI) is receiving attention as a new low-emission engine concept. Little is known about the optimal operating conditions for this engine operation mode. Combustion under homogeneous, low equivalence ratio conditions results in modest temperature combustion products, containing very low concentrations of NO{sub x} and particulate matter (PM) as well as providing high thermal efficiency. However, this combustion mode can produce higher HC and CO emissions than those of conventional engines. An electronically controlled Caterpillar single-cylinder oil test engine (SCOTE), originally designed for heavy-duty diesel applications, was converted to an HCCI direct injection (DI) gasoline engine. The engine features an electronically controlled low-pressure direct injection gasoline (DI-G) injector with a 60 deg spray angle that is capable of multiple injections. The use of double injection was explored for emission control and the engine was optimized using fully automated experiments and a microgenetic algorithm optimization code. The variables changed during the optimization include the intake air temperature, start of injection timing and the split injection parameters (per cent mass of fuel in each injection, dwell between the pulses). The engine performance and emissions were determined at 700 r/min with a constant fuel flowrate at 10 MPa fuel injection pressure. The results show that significant emissions reductions are possible with the use of optimal injection strategies. (Author)

  2. LabVIEW-based sequential-injection analysis system for the determination of trace metals by square-wave anodic and adsorptive stripping voltammetry on mercury-film electrodes.

    Science.gov (United States)

    Economou, Anastasios; Voulgaropoulos, Anastasios

    2003-01-01

    The development of a dedicated automated sequential-injection analysis apparatus for anodic stripping voltammetry (ASV) and adsorptive stripping voltammetry (AdSV) is reported. The instrument comprised a peristaltic pump, a multiposition selector valve and a home-made potentiostat and used a mercury-film electrode as the working electrodes in a thin-layer electrochemical detector. Programming of the experimental sequence was performed in LabVIEW 5.1. The sequence of operations included formation of the mercury film, electrolytic or adsorptive accumulation of the analyte on the electrode surface, recording of the voltammetric current-potential response, and cleaning of the electrode. The stripping step was carried out by applying a square-wave (SW) potential-time excitation signal to the working electrode. The instrument allowed unattended operation since multiple-step sequences could be readily implemented through the purpose-built software. The utility of the analyser was tested for the determination of copper(II), cadmium(II), lead(II) and zinc(II) by SWASV and of nickel(II), cobalt(II) and uranium(VI) by SWAdSV.

  3. Automated method for simultaneous lead and strontium isotopic analysis applied to rainwater samples and airborne particulate filters (PM10).

    Science.gov (United States)

    Beltrán, Blanca; Avivar, Jessica; Mola, Montserrat; Ferrer, Laura; Cerdà, Víctor; Leal, Luz O

    2013-09-03

    A new automated, sensitive, and fast system for the simultaneous online isolation and preconcentration of lead and strontium by sorption on a microcolumn packed with Sr-resin using an inductively coupled plasma mass spectrometry (ICP-MS) detector was developed, hyphenating lab-on-valve (LOV) and multisyringe flow injection analysis (MSFIA). Pb and Sr are directly retained on the sorbent column and eluted with a solution of 0.05 mol L(-1) ammonium oxalate. The detection limits achieved were 0.04 ng for lead and 0.03 ng for strontium. Mass calibration curves were used since the proposed system allows the use of different sample volumes for preconcentration. Mass linear working ranges were between 0.13 and 50 ng and 0.1 and 50 ng for lead and strontium, respectively. The repeatability of the method, expressed as RSD, was 2.1% and 2.7% for Pb and Sr, respectively. Environmental samples such as rainwater and airborne particulate (PM10) filters as well as a certified reference material SLRS-4 (river water) were satisfactorily analyzed obtaining recoveries between 90 and 110% for both elements. The main features of the LOV-MSFIA-ICP-MS system proposed are the capability to renew solid phase extraction at will in a fully automated way, the remarkable stability of the column which can be reused up to 160 times, and the potential to perform isotopic analysis.

  4. Iterative User Interface Design for Automated Sequential Organ Failure Assessment Score Calculator in Sepsis Detection.

    Science.gov (United States)

    Aakre, Christopher Ansel; Kitson, Jaben E; Li, Man; Herasevich, Vitaly

    2017-05-18

    The new sepsis definition has increased the need for frequent sequential organ failure assessment (SOFA) score recalculation and the clerical burden of information retrieval makes this score ideal for automated calculation. The aim of this study was to (1) estimate the clerical workload of manual SOFA score calculation through a time-motion analysis and (2) describe a user-centered design process for an electronic medical record (EMR) integrated, automated SOFA score calculator with subsequent usability evaluation study. First, we performed a time-motion analysis by recording time-to-task-completion for the manual calculation of 35 baseline and 35 current SOFA scores by 14 internal medicine residents over a 2-month period. Next, we used an agile development process to create a user interface for a previously developed automated SOFA score calculator. The final user interface usability was evaluated by clinician end users with the Computer Systems Usability Questionnaire. The overall mean (standard deviation, SD) time-to-complete manual SOFA score calculation time was 61.6 s (33). Among the 24% (12/50) usability survey respondents, our user-centered user interface design process resulted in >75% favorability of survey items in the domains of system usability, information quality, and interface quality. Early stakeholder engagement in our agile design process resulted in a user interface for an automated SOFA score calculator that reduced clinician workload and met clinicians' needs at the point of care. Emerging interoperable platforms may facilitate dissemination of similarly useful clinical score calculators and decision support algorithms as "apps." A user-centered design process and usability evaluation should be considered during creation of these tools. ©Christopher Ansel Aakre, Jaben E Kitson, Man Li, Vitaly Herasevich. Originally published in JMIR Human Factors (http://humanfactors.jmir.org), 18.05.2017.

  5. Simultaneous determination of rutin and ascorbic acid in a sequential injection lab-at-valve system.

    Science.gov (United States)

    Al-Shwaiyat, Mohammed Khair E A; Miekh, Yuliia V; Denisenko, Tatyana A; Vishnikin, Andriy B; Andruch, Vasil; Bazel, Yaroslav R

    2018-02-05

    A green, simple, accurate and highly sensitive sequential injection lab-at-valve procedure has been developed for the simultaneous determination of ascorbic acid (Asc) and rutin using 18-molybdo-2-phosphate Wells-Dawson heteropoly anion (18-MPA). The method is based on the dependence of the reaction rate between 18-MPA and reducing agents on the solution pH. Only Asc is capable of interacting with 18-MPA at pH 4.7, while at pH 7.4 the reaction with both Asc and rutin proceeds simultaneously. In order to improve the precision and sensitivity of the analysis, to minimize reagent consumption and to remove the Schlieren effect, the manifold for the sequential injection analysis was supplemented with external reaction chamber, and the reaction mixture was segmented. By the reduction of 18-MPA with reducing agents one- and two-electron heteropoly blues are formed. The fraction of one-electron heteropoly blue increases at low concentrations of the reducer. Measurement of the absorbance at a wavelength corresponding to the isobestic point allows strictly linear calibration graphs to be obtained. The calibration curves were linear in the concentration ranges of 0.3-24mgL -1 and 0.2-14mgL -1 with detection limits of 0.13mgL -1 and 0.09mgL -1 for rutin and Asc, respectively. The determination of rutin was possible in the presence of up to a 20-fold molar excess of Asc. The method was applied to the determination of Asc and rutin in ascorutin tablets with acceptable accuracy and precision (1-2%). Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Laser desorption/ionization from nanostructured surfaces: nanowires, nanoparticle films and silicon microcolumn arrays

    International Nuclear Information System (INIS)

    Chen Yong; Luo Guanghong; Diao Jiajie; Chornoguz, Olesya; Reeves, Mark; Vertes, Akos

    2007-01-01

    Due to their optical properties and morphology, thin films formed of nanoparticles are potentially new platforms for soft laser desorption/ionization (SLDI) mass spectrometry. Thin films of gold nanoparticles (with 12±1 nm particle size) were prepared by evaporation-driven vertical colloidal deposition and used to analyze a series of directly deposited polypeptide samples. In this new SLDI method, the required laser fluence for ion detection was equal or less than what was needed for matrix-assisted laser desorption/ionization (MALDI) but the resulting spectra were free of matrix interferences. A silicon microcolumn array-based substrate (a.k.a. black silicon) was developed as a new matrix-free laser desorption ionization surface. When low-resistivity silicon wafers were processed with a 22 ps pulse length 3xω Nd:YAG laser in air, SF 6 or water environment, regularly arranged conical spikes emerged. The radii of the spike tips varied with the processing environment, ranging from approximately 500 nm in water, to ∼2 μm in SF 6 gas and to ∼5 μm in air. Peptide mass spectra directly induced by a nitrogen laser showed the formation of protonated ions of angiotensin I and II, substance P, bradykinin fragment 1-7, synthetic peptide, pro14-arg, and insulin from the processed silicon surfaces but not from the unprocessed areas. Threshold fluences for desorption/ionization were similar to those used in MALDI. Although compared to silicon nanowires the threshold laser pulse energy for ionization is significantly (∼10x) higher, the ease of production and robustness of microcolumn arrays offer complementary benefits

  7. Early Stages of Pulsed-Laser Growth of Silicon Microcolumns and Microcones in Air and SF6

    International Nuclear Information System (INIS)

    Fowlkes, J.D.; Lowndes, D.H.; Pedraza, A.J.

    1999-01-01

    Dense arrays of high-aspect-ratio silicon microcolumns and microcones are formed by cumulative nanosecond pulsed excimer laser irradiation of single-crystal silicon in oxidizing atmospheres such as air and SF 6 . Growth of such surface microstructures requires a redeposition model and also involves elements of self-organization. The shape of the microstructures, i.e. straight columns vs steeply sloping cones and connecting walls, is governed by the type and concentration of the oxidizing species, e.g. oxygen vs fluorine. Growth is believed to occur by a catalyst-free VLS (vapor-liquid-solid) mechanism that involves repetitive melting of the tips of the columns/cones and deposition there of the ablated flux of Si-containing vapor. Results are presented of a new investigation of how such different final microstructures as microcolumns or microcones joined by walls nucleate and develop. The changes in silicon surface morphology were systematically determined and compared as the number of pulsed KrF (248 nm) laser shots was increased from 25 to several thousand in both air and SF 6 . The experiments in air and SF 6 reveal significant differences in initial surface cracking and pattern formation. Consequently, local protrusions are first produced and column or cone/wall growth is initiated by different processes and at different rates. Differences in the spatial organization of column or cone/wall growth also are apparent

  8. Performance Evaluation of a Software Engineering Tool for Automated Design of Cooling Systems in Injection Moulding

    DEFF Research Database (Denmark)

    Jauregui-Becker, Juan M.; Tosello, Guido; van Houten, Fred J.A.M.

    2013-01-01

    This paper presents a software tool for automating the design of cooling systems for injection moulding and a validation of its performance. Cooling system designs were automatically generated by the proposed software tool and by applying a best practice tool engineering design approach. The two...

  9. Determination of dissolved inorganic carbon (DIC) and dissolved organic carbon (DOC) in freshwaters by sequential injection spectrophotometry with on-line UV photo-oxidation

    International Nuclear Information System (INIS)

    Tue-Ngeun, Orawan; Sandford, Richard C.; Jakmunee, Jaroon; Grudpan, Kate; McKelvie, Ian D.; Worsfold, Paul J.

    2005-01-01

    An automated sequential injection (SI) method for the determination of dissolved inorganic carbon (DIC) and dissolved organic carbon (DOC) in freshwaters is presented. For DIC measurement on-line sample acidification (sulphuric acid, pH 2 which subsequently diffused through a PTFE membrane into a basic, cresol red acceptor stream. The CO 2 increased the concentration of the acidic form of the cresol red indicator, with a resultant decrease in absorbance at 570 nm being directly proportional to DIC concentration. DIC + DOC was determined after on-line sample irradiation (15 W low power UV lamp) coupled with acid-peroxydisulfate digestion, with the subsequent detection of CO 2 as described above. DOC was determined by subtraction of DIC from (DIC + DOC). Analytical figures of merit were linear ranges of 0.05-5.0 mg C L -1 for both DIC and DIC + DOC, with typical R.S.D.s of less than 7% (0.05 mg C L -1 -5.3% for DIC and 6.6% for DIC + DOC; 4.0 mg C L -1 -2.6% for DIC and 2.4% for DIC + DOC, n = 3) and an LOD (blank + 3S.D.) of 0.05 mg C L -1 . Sample throughput for the automated system was 8 h -1 for DIC and DOC with low reagent consumption (acid/peroxydisulfate 200 μL per DIC + DOC analysis). A range of model carbon compounds and Tamar River (Plymouth, UK) samples were analysed for DIC and DOC and the results showed good agreement with a high temperature catalytic oxidation (HTCO) reference method (t-test, P = 0.05)

  10. Determination of dissolved inorganic carbon (DIC) and dissolved organic carbon (DOC) in freshwaters by sequential injection spectrophotometry with on-line UV photo-oxidation

    Energy Technology Data Exchange (ETDEWEB)

    Tue-Ngeun, Orawan [Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Sandford, Richard C. [School of Earth, Ocean and Environmental Sciences, University of Plymouth, Drakes Circus, Plymouth PL4 8AA (United Kingdom)]. E-mail: rsandford@plymouth.ac.uk; Jakmunee, Jaroon [Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Grudpan, Kate [Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); McKelvie, Ian D. [Water Studies Centre, School of Chemistry, Monash University, P.O. Box 23, Clayton Campus, Vic. 3800 (Australia); Worsfold, Paul J. [School of Earth, Ocean and Environmental Sciences, University of Plymouth, Drakes Circus, Plymouth PL4 8AA (United Kingdom)

    2005-12-04

    An automated sequential injection (SI) method for the determination of dissolved inorganic carbon (DIC) and dissolved organic carbon (DOC) in freshwaters is presented. For DIC measurement on-line sample acidification (sulphuric acid, pH < 2), converted DIC to CO{sub 2} which subsequently diffused through a PTFE membrane into a basic, cresol red acceptor stream. The CO{sub 2} increased the concentration of the acidic form of the cresol red indicator, with a resultant decrease in absorbance at 570 nm being directly proportional to DIC concentration. DIC + DOC was determined after on-line sample irradiation (15 W low power UV lamp) coupled with acid-peroxydisulfate digestion, with the subsequent detection of CO{sub 2} as described above. DOC was determined by subtraction of DIC from (DIC + DOC). Analytical figures of merit were linear ranges of 0.05-5.0 mg C L{sup -1} for both DIC and DIC + DOC, with typical R.S.D.s of less than 7% (0.05 mg C L{sup -1}-5.3% for DIC and 6.6% for DIC + DOC; 4.0 mg C L{sup -1}-2.6% for DIC and 2.4% for DIC + DOC, n = 3) and an LOD (blank + 3S.D.) of 0.05 mg C L{sup -1}. Sample throughput for the automated system was 8 h{sup -1} for DIC and DOC with low reagent consumption (acid/peroxydisulfate 200 {mu}L per DIC + DOC analysis). A range of model carbon compounds and Tamar River (Plymouth, UK) samples were analysed for DIC and DOC and the results showed good agreement with a high temperature catalytic oxidation (HTCO) reference method (t-test, P = 0.05)

  11. On-line preconcentration system using a microcolumn packed with Alizarin Red S-modified alumina for zinc determination by flame atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    A.M. Haji Shabani

    2009-01-01

    Full Text Available A simple and sensitive on-line flow injection system for determination of zinc with FAAS has been described. The method is based on the separation and preconcentration of zinc on a microcolumn of immobilized Alizarin Red S on alumina. The adsorbed analyte is then eluted with 250 µL of nitric acid (1 mol L-1 and is transported to flame atomic absorption spectrometer for quantification. The effect of pH, sample and eluent flow rates and presence of various cations and anions on the retention of zinc was investigated. The sorption of zinc was quantitative in the pH range of 5.5-8.5. For a sample volume of 25 mL an enrichment factor of 144 and a detection limit (3S of 0.2 µg L-1 was obtained. The precision (RSD, n=7 was 3.0% at the 20 µg L-1 level. The developed system was successfully applied to the determination of zinc in water samples, hair, urine and saliva.

  12. Single peak parameters technique for simultaneous measurements: Spectrophotometric sequential injection determination of Fe(II) and Fe(III).

    Science.gov (United States)

    Kozak, J; Paluch, J; Węgrzecka, A; Kozak, M; Wieczorek, M; Kochana, J; Kościelniak, P

    2016-02-01

    Spectrophotometric sequential injection system (SI) is proposed to automate the method of simultaneous determination of Fe(II) and Fe(III) on the basis of parameters of a single peak. In the developed SI system, sample and mixture of reagents (1,10-phenanthroline and sulfosalicylic acid) are introduced into a vessel, where in an acid environment (pH≅3) appropriate compounds of Fe(II) and Fe(III) with 1,10-phenanthroline and sulfosalicylic acid are formed, respectively. Then, in turn, air, sample, EDTA and sample again, are introduced into a holding coil. After the flow reversal, a segment of air is removed from the system by an additional valve and as EDTA replaces sulfosalicylic acid forming a more stable colorless compound with Fe(III), a complex signal is registered. Measurements are performed at wavelength 530 nm. The absorbance measured at minimum of the negative peak and the area or the absorbance measured at maximum of the signal can be used as measures corresponding to Fe(II) and Fe(III) concentrations, respectively. The time of the peak registration is about 2 min. Two-component calibration has been applied to analysis. Fe(II) and Fe(III) can be determined within the concentration ranges of 0.04-4.00 and 0.1-5.00 mg L(-1), with precision less than 2.8% and 1.7% (RSD), respectively and accuracy better than 7% (RE). The detection limit is 0.04 and 0.09 mg L(-1) for Fe(II) and Fe(III), respectively. The method was applied to analysis of artesian water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Investigation of arsenic removal in batch wise water treatments by means of sequential hydride generation flow injection analysis.

    Science.gov (United States)

    Toda, Kei; Takaki, Mari; Hashem, Md Abul

    2008-08-01

    Arsenic water pollution is a big issue worldwide. Determination of inorganic arsenic in each oxidation state is important because As(III) is much more toxic than As(V). An automated arsenic measurement system was developed based on complete vaporization of As by a sequential procedure and collection/preconcentration of the vaporized AsH(3), which was subsequently measured by a flow analysis. The automated sensitive method was applied to monitoring As(III) and As(V) concentrations in contaminated water standing overnight. Behaviors of arsenics were investigated in different conditions, and unique time dependence profiles were obtained. For example, in the standing of anaerobic water samples, the As(III) concentration immediately began decreasing whereas dead time was observed in the removal of As(V). In normal groundwater conditions, most arsenic was removed from the water simply by standing overnight. To obtain more effective removal, the addition of oxidants and use of steel wools were investigated. Simple batch wise treatments of arsenic contaminated water were demonstrated, and detail of the transitional changes in As(III) and As(V) were investigated.

  14. Automation of radiochemical analysis by flow injection techniques. Am-Pu separation using TRU-resinTM sorbent extraction column

    International Nuclear Information System (INIS)

    Egorov, O.; Washington Univ., Seattle, WA; Grate, J.W.; Ruzicka, J.

    1998-01-01

    A rapid automated flow injection analysis (FIA) procedure was developed for efficient separation of Am and Pu from each other and from interfering matrix and radionuclide components using a TRU-resin TM column. Selective Pu elution is enabled via on-column reduction. The separation was developed using on-line radioactivity detection. After the separation had been developed, fraction collection was used to obtain the separated fractions. In this manner, a FIA instrument functions as an automated separation workstation capable of unattended operation. (author)

  15. Visual detection and sequential injection determination of aluminium using a cinnamoyl derivative.

    Science.gov (United States)

    Elečková, Lenka; Alexovič, Michal; Kuchár, Juraj; Balogh, Ioseph S; Andruch, Vasil

    2015-02-01

    A cinnamoyl derivative, 3-[4-(dimethylamino)cinnamoyl]-4-hydroxy-6-methyl-3,4-2H-pyran-2-one, was used as a ligand for the determination of aluminium. Upon the addition of an acetonitrile solution of the ligand to an aqueous solution containing Al(III) and a buffer solution at pH 8, a marked change in colour from yellow to orange is observed. The colour intensity is proportional to the concentration of Al(III); thus, the 'naked-eye' detection of aluminium is possible. The reaction is also applied for sequential injection determination of aluminium. Beer׳s law is obeyed in the range from 0.055 to 0.66 mg L(-1) of Al(III). The limit of detection, calculated as three times the standard deviation of the blank test (n=10), was found to be 4 μg L(-1) for Al(III). The method was applied for the determination of aluminium in spiked water samples and pharmaceutical preparations. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Immersed single-drop microextraction interfaced with sequential injection analysis for determination of Cr(VI) in natural waters by electrothermal-atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Pena, Francisco; Lavilla, Isela; Bendicho, Carlos

    2008-01-01

    Single-drop microextraction (SDME) and sequential injection analysis have been hyphenated for ultratrace metal determination by Electrothermal-Atomic Absorption Spectrometry (ETAAS). The novel method was targeted on extraction of the Cr(VI)-APDC chelate and encompasses the potential of SDME as a miniaturized and virtually solvent-free preconcentration technique, the ability of sequential injection analysis to handle samples and the versatility of furnace autosamplers for introducing microliter samples in ETAAS. The variables influencing the microextraction of Cr(VI) onto an organic solvent drop, i.e., type of organic solvent, microextraction time, stirring rate of the sample solution, drop volume, immersion depth of the drop, salting-out effect, temperature of the sample, concentration of the complexing agent and pH of the sample solution were fully investigated. For a 5 and 20 min microextraction time, the preconcentration factors were 20 and 70, respectively. The detection limit was 0.02 μg/L of Cr(VI) and the repeatability expressed as relative standard deviation was 7%. The SDME-SIA-ETAAS technique was validated against BCR CRM 544 (lyophilized solution) and applied to ultrasensitive determination of Cr(VI) in natural waters

  17. Immersed single-drop microextraction interfaced with sequential injection analysis for determination of Cr(VI) in natural waters by electrothermal-atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Pena, Francisco; Lavilla, Isela [Departamento de Quimica Analitica y Alimentaria, Area de Quimica Analitica, Facultad de Quimica, Universidad de Vigo, Campus As Lagoas-Marcosende, s/n, 36310 Vigo (Spain); Bendicho, Carlos [Departamento de Quimica Analitica y Alimentaria, Area de Quimica Analitica, Facultad de Quimica, Universidad de Vigo, Campus As Lagoas-Marcosende, s/n, 36310 Vigo (Spain)], E-mail: bendicho@uvigo.es

    2008-04-15

    Single-drop microextraction (SDME) and sequential injection analysis have been hyphenated for ultratrace metal determination by Electrothermal-Atomic Absorption Spectrometry (ETAAS). The novel method was targeted on extraction of the Cr(VI)-APDC chelate and encompasses the potential of SDME as a miniaturized and virtually solvent-free preconcentration technique, the ability of sequential injection analysis to handle samples and the versatility of furnace autosamplers for introducing microliter samples in ETAAS. The variables influencing the microextraction of Cr(VI) onto an organic solvent drop, i.e., type of organic solvent, microextraction time, stirring rate of the sample solution, drop volume, immersion depth of the drop, salting-out effect, temperature of the sample, concentration of the complexing agent and pH of the sample solution were fully investigated. For a 5 and 20 min microextraction time, the preconcentration factors were 20 and 70, respectively. The detection limit was 0.02 {mu}g/L of Cr(VI) and the repeatability expressed as relative standard deviation was 7%. The SDME-SIA-ETAAS technique was validated against BCR CRM 544 (lyophilized solution) and applied to ultrasensitive determination of Cr(VI) in natural waters.

  18. Determination of dasatinib in the tablet dosage form by ultra high performance liquid chromatography, capillary zone electrophoresis, and sequential injection analysis.

    Science.gov (United States)

    Gonzalez, Aroa Garcia; Taraba, Lukáš; Hraníček, Jakub; Kozlík, Petr; Coufal, Pavel

    2017-01-01

    Dasatinib is a novel oral prescription drug proposed for treating adult patients with chronic myeloid leukemia. Three analytical methods, namely ultra high performance liquid chromatography, capillary zone electrophoresis, and sequential injection analysis, were developed, validated, and compared for determination of the drug in the tablet dosage form. The total analysis time of optimized ultra high performance liquid chromatography and capillary zone electrophoresis methods was 2.0 and 2.2 min, respectively. Direct ultraviolet detection with detection wavelength of 322 nm was employed in both cases. The optimized sequential injection analysis method was based on spectrophotometric detection of dasatinib after a simple colorimetric reaction with folin ciocalteau reagent forming a blue-colored complex with an absorbance maximum at 745 nm. The total analysis time was 2.5 min. The ultra high performance liquid chromatography method provided the lowest detection and quantitation limits and the most precise and accurate results. All three newly developed methods were demonstrated to be specific, linear, sensitive, precise, and accurate, providing results satisfactorily meeting the requirements of the pharmaceutical industry, and can be employed for the routine determination of the active pharmaceutical ingredient in the tablet dosage form. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Flow-injection system for automated dissolution testing of isoniazid tablets with chemiluminescence detection.

    Science.gov (United States)

    Li, B; Zhang, Z; Liu, W

    2001-05-30

    A simple and sensitive flow-injection chemiluminescence (CL) system for automated dissolution testing is described and evaluated for monitoring of dissolution profiles of isoniazid tablets. The undissolved suspended particles in the dissolved solution were eliminated via on-line filter. The novel CL system of KIO(4)-isoniazid was also investigated. The sampling frequency of the system was 120 h(-1). The dissolution profiles of isoniazid fast-release tablets from three sources were determined, which demonstrates the stability, great sensitivity, large dynamic measuring range and robustness of the system.

  20. Highly selective enrichment of phosphorylated peptides from peptide mixtures using titanium dioxide microcolumns

    DEFF Research Database (Denmark)

    Larsen, Martin Røssel; Thingholm, Tine E; Jensen, Ole N

    2005-01-01

    based on TiO2microcolumns and peptide loading in 2,5-dihydroxybenzoic acid (DHB). The effect of DHB was a very efficient reduction in the binding of nonphosphorylated peptides to TiO2 while retaining its high binding affinity for phosphorylated peptides. Thus, inclusion of DHB dramatically increased...... the selectivity of the enrichment of phosphorylated peptides by TiO2. We demonstrated that this new procedure was more selective for binding phosphorylated peptides than IMAC using MALDI mass spectrometry. In addition, we showed that LC-ESI-MSMS was biased toward monophosphorylated peptides, whereas MALDI MS...... was not. Other substituted aromatic carboxylic acids were also capable of specifically reducing binding of nonphosphorylated peptides, whereas phosphoric acid reduced binding of both phosphorylated and nonphosphorylated peptides. A putative mechanism for this intriguing effect is presented....

  1. PLC and SCADA based automation of injection casting process for casting of uranium-zirconium blanket fuel slugs for metallic fuel fabrication

    International Nuclear Information System (INIS)

    Yathish Kumar, G.; Jagadeeschandran, J.; Avvaru, Prafulla Kumar; Yadaw, Abhishek Kumar; Lavakumar, R.; Prabhu, T.V.; Muralidharan, P.; Anthonysamy, S.

    2016-01-01

    Fabrication of metallic (U-6wt.%Zr) slugs involves melting of binary alloy under vacuum and injection casting into quartz moulds at high pressure. Injection casting system housed inside glove box comprises of high vacuum, induction melting, high pressure control, motion control, mould preheating, chamber cooling, crucible handling and glove box pressure control systems. The technology development for process automation of injection casting system and process optimisation for fabrication of metallic (U-6%Zr) slugs is outlined in this paper. (author)

  2. FI/SI on-line solvent extraction/back extraction preconcentration coupled to direct injection nebulization inductively coupled plasma mass spectrometry for determination of copper and lead

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2002-01-01

    An automated sequential injection on-line preconcentration procedure for determination of trace levels of copper and lead via solvent extraction/back extraction coupled to ICP-MS is described. In citrate buffer of pH 3, neutral complexes between the analytes and the chelating reagent, ammonium...... loop, the content of which is subsequently introduced into the ICP-MS, via a direct injection high efficiency nebulizer (DIHEN), for quantification. Enrichment factors of 29.6 (Cu) and 23.3 (Pb), detection limits of 17 ng/l (Cu) and 11 ng/l (Pb), along with a sampling frequency of 13 s/h were obtained...

  3. Characterization of gel-separated glycoproteins using two-step proteolytic digestion combined with sequential microcolumns and mass spectrometry

    DEFF Research Database (Denmark)

    Larsen, Martin Røssel; Højrup, Peter; Roepstorff, Peter

    2005-01-01

    present a new technique that allows characterization of low amounts of glycoproteins separated by gel electrophoresis. The method takes advantage of sequential specific and nonspecific enzymatic treatment followed by selective purification and characterization of the glycopeptides using graphite powder......Protein glycosylation can be vital for changing the function or physiochemical properties of a protein. Abnormal glycosylation can lead to protein malfunction, resulting in severe diseases. Therefore, it is important to develop techniques for characterization of such modifications in proteins...... at a sensitivity level comparable with state-of-the-art proteomics. Whereas techniques exist for characterization of high abundance glycoproteins, no single method is presently capable of providing information on both site occupancy and glycan structure on a single band excised from an electrophoretic gel. We...

  4. Development of a flow method for the determination of phosphate in estuarine and freshwaters-Comparison of flow cells in spectrophotometric sequential injection analysis

    International Nuclear Information System (INIS)

    Mesquita, Raquel B.R.; Ferreira, M. Teresa S.O.B.; Toth, Ildiko V.; Bordalo, Adriano A.; McKelvie, Ian D.; Rangel, Antonio O.S.S.

    2011-01-01

    Highlights: → Sequential injection determination of phosphate in estuarine and freshwaters. → Alternative spectrophotometric flow cells are compared. → Minimization of schlieren effect was assessed. → Proposed method can cope with wide salinity ranges. → Multi-reflective cell shows clear advantages. - Abstract: A sequential injection system with dual analytical line was developed and applied in the comparison of two different detection systems viz; a conventional spectrophotometer with a commercial flow cell, and a multi-reflective flow cell coupled with a photometric detector under the same experimental conditions. The study was based on the spectrophotometric determination of phosphate using the molybdenum-blue chemistry. The two alternative flow cells were compared in terms of their response to variation of sample salinity, susceptibility to interferences and to refractive index changes. The developed method was applied to the determination of phosphate in natural waters (estuarine, river, well and ground waters). The achieved detection limit (0.007 μM PO 4 3- ) is consistent with the requirement of the target water samples, and a wide quantification range (0.024-9.5 μM) was achieved using both detection systems.

  5. Development of a flow method for the determination of phosphate in estuarine and freshwaters-Comparison of flow cells in spectrophotometric sequential injection analysis

    Energy Technology Data Exchange (ETDEWEB)

    Mesquita, Raquel B.R. [CBQF/Escola Superior de Biotecnologia, Universidade Catolica Portuguesa, R. Dr. Antonio Bernardino de Almeida, 4200-072 Porto (Portugal); Laboratory of Hydrobiology, Institute of Biomedical Sciences Abel Salazar (ICBAS) and Institute of Marine Research (CIIMAR), Universidade do Porto, Lg. Abel Salazar 2, 4099-003 Porto (Portugal); Ferreira, M. Teresa S.O.B. [CBQF/Escola Superior de Biotecnologia, Universidade Catolica Portuguesa, R. Dr. Antonio Bernardino de Almeida, 4200-072 Porto (Portugal); Toth, Ildiko V. [REQUIMTE, Departamento de Quimica, Faculdade de Farmacia, Universidade de Porto, Rua Anibal Cunha, 164, 4050-047 Porto (Portugal); Bordalo, Adriano A. [Laboratory of Hydrobiology, Institute of Biomedical Sciences Abel Salazar (ICBAS) and Institute of Marine Research (CIIMAR), Universidade do Porto, Lg. Abel Salazar 2, 4099-003 Porto (Portugal); McKelvie, Ian D. [School of Chemistry, University of Melbourne, Victoria 3010 (Australia); Rangel, Antonio O.S.S., E-mail: aorangel@esb.ucp.pt [CBQF/Escola Superior de Biotecnologia, Universidade Catolica Portuguesa, R. Dr. Antonio Bernardino de Almeida, 4200-072 Porto (Portugal)

    2011-09-02

    Highlights: {yields} Sequential injection determination of phosphate in estuarine and freshwaters. {yields} Alternative spectrophotometric flow cells are compared. {yields} Minimization of schlieren effect was assessed. {yields} Proposed method can cope with wide salinity ranges. {yields} Multi-reflective cell shows clear advantages. - Abstract: A sequential injection system with dual analytical line was developed and applied in the comparison of two different detection systems viz; a conventional spectrophotometer with a commercial flow cell, and a multi-reflective flow cell coupled with a photometric detector under the same experimental conditions. The study was based on the spectrophotometric determination of phosphate using the molybdenum-blue chemistry. The two alternative flow cells were compared in terms of their response to variation of sample salinity, susceptibility to interferences and to refractive index changes. The developed method was applied to the determination of phosphate in natural waters (estuarine, river, well and ground waters). The achieved detection limit (0.007 {mu}M PO{sub 4}{sup 3-}) is consistent with the requirement of the target water samples, and a wide quantification range (0.024-9.5 {mu}M) was achieved using both detection systems.

  6. Bioremediation of PAHs contaminated river sediment by an integrated approach with sequential injection of co-substrate and electron acceptor: Lab-scale study

    International Nuclear Information System (INIS)

    Liu, Tongzhou; Zhang, Zhen; Dong, Wenyi; Wu, Xiaojing; Wang, Hongjie

    2017-01-01

    In this study, the feasibility of employing an integrated bioremediation approach in contaminated river sediment was evaluated. Sequential addition of co-substrate (acetate) and electron acceptor (NO 3 − ) in a two-phase treatment was capable of effectively removing polycyclic aromatic hydrocarbons (PAHs) in river sediment. The residual concentration of total PAHs decreased to far below effect range low (ERL) value within 91 days of incubation, at which concentration it could rarely pose biological impairment. The biodegradation of high molecular weight PAHs were found to be mainly occurred in the sediment treated with co-substrates (i.e. acetate or methanol), in which acetate was found to be more suitable for PAHs degradation. The role of co-substrates in influencing PAHs biodegradation was tentatively discussed herein. Additionally, the sediment odorous problem and blackish appearance were intensively addressed by NO 3 − injection. The results of this study demonstrated that integrating two or more approaches/processes would be a helpful option in sediment remediation. It can lead to a more effective remediation performance, handle multiple contamination issues, as well as mitigate environmental risks caused by one of the single methods. - Highlights: • Sequential addition of acetate and NO 3 − removed PAHs and mitigated sediment odor. • Acetate is a suitable co-substrate used for PAHs degradation in river sediment. • NO 3 − Injection was effective for sediment odor and blackish appearance mitigation. • Integrated method is suggested in complicated real case with multi-remedial target. - Sequential addition of co-substrate and electron acceptor was capable of effectively removing PAHs and addressing sediment odorous problem and blackish appearance.

  7. Automated thermometric enzyme immunoassay of human proinsulin produced by Escherichia coli.

    Science.gov (United States)

    Birnbaum, S; Bülow, L; Hardy, K; Danielsson, B; Mosbach, K

    1986-10-01

    We have determined and monitored the production and release of human proinsulin by genetically engineered Escherichia coli cells. Several M9 media samples were analyzed sequentially after centrifugation with the aid of a rapid automated flow-through thermometric enzyme-linked immunosorbent assay (TELISA) system. The response time was 7 min after sample injection and a single assay was complete after 13 min. Insulin concentrations in the range of 0.1-50 micrograms/ml could be determined. The TELISA method correlated well with conventional radioimmunoassay determinations. Standard curves were reproducible over a period of several days even when the immobilized antibody column was stored at 25 degrees C in the enzyme thermistor unit. Thus, immediate assay start up was possible.

  8. The use of titanium dioxide micro-columns to selectively isolate phosphopeptides from proteolytic digests

    DEFF Research Database (Denmark)

    Thingholm, Tine E; Larsen, Martin R

    2009-01-01

    Titanium dioxide has very high affinity for phosphopeptides and it has become an efficient alternative to already existing methods for phosphopeptide enrichment from complex samples. Peptide loading in a highly acidic environment in the presence of 2,5-dihydroxybenzoic acid (DHB), phthalic acid......, or glycolic acid has been shown to improve selectivity significantly by reducing unspecific binding from nonphosphorylated peptides. The enriched phosphopeptides bound to the titanium dioxide are subsequently eluted from the micro-column using an alkaline buffer. Titanium dioxide chromatography is extremely...... tolerant towards most buffers used in biological experiments. It is highly robust and as such it has become one of the methods of choice in large-scale phospho-proteomics. Here we describe the protocol for phosphopeptide enrichment using titanium dioxide chromatography followed by desalting...

  9. Double-label autoradiographic deoxyglucose method for sequential measurement of regional cerebral glucose utilization

    Energy Technology Data Exchange (ETDEWEB)

    Redies, C; Diksic, M; Evans, A C; Gjedde, A; Yamamoto, Y L

    1987-08-01

    A new double-label autoradiographic glucose analog method for the sequential measurement of altered regional cerebral metabolic rates for glucose in the same animal is presented. This method is based on the sequential injection of two boluses of glucose tracer labeled with two different isotopes (short-lived /sup 18/F and long-lived /sup 3/H, respectively). An operational equation is derived which allows the determination of glucose utilization for the time period before the injection of the second tracer; this equation corrects for accumulation and loss of the first tracer from the metabolic pool occurring after the injection of the second tracer. An error analysis of this operational equation is performed. The double-label deoxyglucose method is validated in the primary somatosensory (''barrel'') cortex of the anesthetized rat. Two different rows of whiskers were stimulated sequentially in each rat; the two periods of stimulation were each preceded by an injection of glucose tracer. After decapitation, dried brain slices were first exposed, in direct contact, to standard X-ray film and then to uncoated, ''tritium-sensitive'' film. Results show that the double-label deoxyglucose method proposed in this paper allows the quantification and complete separation of glucose utilization patterns elicited by two different stimulations sequentially applied in the same animal.

  10. Sequential injection chemiluminescence immunoassay for nonionic surfactants by using magnetic microbeads

    International Nuclear Information System (INIS)

    Zhang Ruiq; Nakajima, Hizuru; Soh, Nobuaki; Nakano, Koji; Masadome, Takashi; Nagata, Kazumi; Sakamoto, Kazuhira; Imato, Toshihiko

    2007-01-01

    A rapid and sensitive immunoassay based on a sequential injection analysis (SIA) using magnetic microbeads for the determination of alkylphenol polyethoxylates (APnEOs) is described. An SIA system was constructed from a syringe pump, a switching valve, a flow-through type immunoreaction cell equipped with a photon counting unit and a neodymium magnet. Magnetic beads, to which an anti-APnEOs monoclonal antibody was immobilized, were used as a solid support in an immunoassay. The introduction, trapping and release of the magnetic beads in and from the immunoreaction cell were controlled by means of a neodymium magnet and adjusting the flow of a carrier solution. The immunoassay was based on an indirect competitive immunoreaction of an anti-APnEOs monoclonal antibody immobilized on the magnetic beads with a sample APnEOs and a horseradish peroxidase (HRP)-labeled APnEOs in the same sample solution, and was based on the subsequent chemiluminscence reaction of HRP on the magnetic microbeads with a luminol solution containing hydrogen peroxide and p-iodophenol. The anti-APnEOs antibody was immobilized on the magnetic microbeads by coupling the antibody with the magnetic beads after activation of a carboxylate moiety on the surface of the magnetic beads that had been coated with a polylactic acid film. The antibody immobilized magnetic beads were introduced in the immunoreaction cell and trapped in it by the neodymium magnet, which was equipped beneath the immunoreaction cell. An APnEOs sample solution containing the HRP-labeled APnEOs at a constant concentration, and a luminol solution containing hydrogen peroxide and p-iodophenol were sequentially introduced into the immunoreaction cell, according to an SIA programmed sequence. Chemiluminescence emission was monitored by means of a photon counting unit located at the upper side of the immunoreaction cell by collecting the emitted light with a lens. A typical sigmoidal calibration curve was obtained, when the logarithm

  11. Lab-on-Valve Micro Sequential Injection: A Versatile Approach for Implementing Integrated Sample Pre-preparations and Executing (Bio)Chemical Assays

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    waste generation. Most recently, the Lab-on-Valve (LOV) approach has emerged. Termed the third generation of FIA, the conceptual basis of the LOV is to incorporate all the necessary unit operational manipulations required in a chemical assay, and, when possible, even the detection device, into a single...... small integrated microconduit, or “laboratory”, placed atop a selection valve. In the lecture emphasis will be placed on the LOV approach. Proven itself as a versatile front end to a variety of detection techniques, its utility will be exemplified by various applications. Particular focus......-phase microcolumn concept utilising hydrophobic as well as hydrophilic bead materials. Although ETAAS and ICPMS both are characterised by excellent analytical chemical capabilities, they nevertheless often require that the samples be subjected to suitable pretreatment in order to obtain the necessary sensitivity...

  12. Rapid and Automated Determination of Plutonium and Neptunium in Environmental Samples

    DEFF Research Database (Denmark)

    Qiao, Jixin

    This thesis presents improved analytical methods for rapid and automated determination of plutonium and neptunium in environmental samples using sequential injection (SI) based chromatography and inductively coupled plasma mass spectrometry (ICP-MS). The progress of methodology development...... and optimization for rapid determination of plutonium in environmental samples using SIextraction chromatography prior to inductively coupled plasma mass spectrometry (Paper III); (3) Development of an SI-chromatographic method for simultaneous determination of plutonium and neptunium in environmental samples...... for rapid and simultaneous determination of plutonium and neptunium within an SI system (Paper VI). The results demonstrate that the developed methods in this study are reliable and efficient for accurate assays of trace levels of plutonium and neptunium as demanded in different situations including...

  13. Automated thermometric enzyme immunoassay of human proinsulin produced by Escherichia coli

    International Nuclear Information System (INIS)

    Birnbaum, S.; Buelow, L.; Hardy, K.; Danielsson, B.; Mosbach, K.

    1986-01-01

    The authors have determined and monitored the production and release of human proinsulin by genetically engineered Escherichia coli cells. Several M9 media samples were analyzed sequentially after centrifugation with the aid of a rapid automated flow-through thermometric enzyme-linked immunosorbent assay (TELISA) system. The response time was 7 min after after sample injection and a single assay was complete after 13 min. Insulin concentrations in the range of 0.1-50 μg/ml could be determined. The TELISA method correlated well with conventional radioimmunoassay determinations. Standard curves were reproducible over a period of several days even when the immobilized antibody column was stored at 25 0 C in the enzyme thermistor unit. Thus, immediate assay start up was possible

  14. Rapid and reagent-saving immunoassay using innovative stirring actions of magnetic beads in microreactors in the sequential injection mode.

    Science.gov (United States)

    Tanaka, K; Imagawa, H

    2005-12-15

    We developed new ELISA techniques in sequential injection analysis (SIA) mode using microreactors with content of a few microliters. We immobilized antibodies on magnetic beads 1.0mum in diameter, injected the beads into microreactors and applied rotating magnetic fields of several hundred gauss. Magnetic beads, suspended in liquid in density of approximately 10(9)-10(10) particles per millilitre, form a large number of thin rod clusters, whose length-wise axes are oriented in parallel with the magnetic field. We rotate the Nd magnets below the center of the microreactor by a tiny motor at about 2000-5000rpm. These rotating clusters remarkably accelerate the binding rate of the antibodies with antigens in the liquid. The beads are trapped around the center of the rotating magnetic field even in the flowing liquid. This newly found phenomenon enables easy bead handling in microreactors. Modification of reactor walls with selected blocking reagents was essential, because protein-coated beads often stick to the wall surface and cannot move freely. Washing steps were also shortened.

  15. Automated backbone assignment of labeled proteins using the threshold accepting algorithm

    International Nuclear Information System (INIS)

    Leutner, Michael; Gschwind, Ruth M.; Liermann, Jens; Schwarz, Christian; Gemmecker, Gerd; Kessler, Horst

    1998-01-01

    The sequential assignment of backbone resonances is the first step in the structure determination of proteins by heteronuclear NMR. For larger proteins, an assignment strategy based on proton side-chain information is no longer suitable for the use in an automated procedure. Our program PASTA (Protein ASsignment by Threshold Accepting) is therefore designed to partially or fully automate the sequential assignment of proteins, based on the analysis of NMR backbone resonances plus C β information. In order to overcome the problems caused by peak overlap and missing signals in an automated assignment process, PASTA uses threshold accepting, a combinatorial optimization strategy, which is superior to simulated annealing due to generally faster convergence and better solutions. The reliability of this algorithm is shown by reproducing the complete sequential backbone assignment of several proteins from published NMR data. The robustness of the algorithm against misassigned signals, noise, spectral overlap and missing peaks is shown by repeating the assignment with reduced sequential information and increased chemical shift tolerances. The performance of the program on real data is finally demonstrated with automatically picked peak lists of human nonpancreatic synovial phospholipase A 2 , a protein with 124 residues

  16. Lab-on-Valve Micro Sequential Injection: A Versatile Approach for Implementing Integrated Sample Pre-preparations and Executing (Bio)Chemical Assays

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    waste generation. Most recently, the socalled third generation of FIA has emerged, that is, the Lab-on-Valve (LOV) approach, the conceptual basis of which is to incorporate all the necessary unit operational manipulations required, and, when possible, even the detection device into a single small...... integrated microconduit, or “laboratory”, placed atop a selection valve. The lecture will detail the evolution of the three generations of FIA, emphasis being placed on the LOV approach. Proven itself as a versatile front end to a variety of detection techniques, its utility will be exemplified by a series...... of the renewable microcolumn concept. Despite their excellent analytical chemical capabilities, ETAAS as well as ICPMS often require that the samples are subjected to suitable pretreatment in order to obtain the necessary sensitivity and selectivity. Either in order to separate the analyte from potentially...

  17. Smartnotebook: A semi-automated approach to protein sequential NMR resonance assignments

    International Nuclear Information System (INIS)

    Slupsky, Carolyn M.; Boyko, Robert F.; Booth, Valerie K.; Sykes, Brian D.

    2003-01-01

    Complete and accurate NMR spectral assignment is a prerequisite for high-throughput automated structure determination of biological macromolecules. However, completely automated assignment procedures generally encounter difficulties for all but the most ideal data sets. Sources of these problems include difficulty in resolving correlations in crowded spectral regions, as well as complications arising from dynamics, such as weak or missing peaks, or atoms exhibiting more than one peak due to exchange phenomena. Smartnotebook is a semi-automated assignment software package designed to combine the best features of the automated and manual approaches. The software finds and displays potential connections between residues, while the spectroscopist makes decisions on which connection is correct, allowing rapid and robust assignment. In addition, smartnotebook helps the user fit chains of connected residues to the primary sequence of the protein by comparing the experimentally determined chemical shifts with expected shifts derived from a chemical shift database, while providing bookkeeping throughout the assignment procedure

  18. Sequential injection titration method using second-order signals: determination of acidity in plant oils and biodiesel samples.

    Science.gov (United States)

    del Río, Vanessa; Larrechi, M Soledad; Callao, M Pilar

    2010-06-15

    A new concept of flow titration is proposed and demonstrated for the determination of total acidity in plant oils and biodiesel. We use sequential injection analysis (SIA) with a diode array spectrophotometric detector linked to chemometric tools such as multivariate curve resolution-alternating least squares (MCR-ALS). This system is based on the evolution of the basic specie of an acid-base indicator, alizarine, when it comes into contact with a sample that contains free fatty acids. The gradual pH change in the reactor coil due to diffusion and reaction phenomenona allows the sequential appearance of both species of the indicator in the detector coil, recording a data matrix for each sample. The SIA-MCR-ALS method helps to reduce the amounts of sample, the reagents and the time consumed. Each determination consumes 0.413ml of sample, 0.250ml of indicator and 3ml of carrier (ethanol) and generates 3.333ml of waste. The frequency of the analysis is high (12 samples h(-1) including all steps, i.e., cleaning, preparing and analysing). The utilized reagents are of common use in the laboratory and it is not necessary to use the reagents of perfect known concentration. The method was applied to determine acidity in plant oil and biodiesel samples. Results obtained by the proposed method compare well with those obtained by the official European Community method that is time consuming and uses large amounts of organic solvents.

  19. A fully automated effervescence assisted dispersive liquid–liquid microextraction based on a stepwise injection system. Determination of antipyrine in saliva samples

    Energy Technology Data Exchange (ETDEWEB)

    Medinskaia, Kseniia; Vakh, Christina; Aseeva, Darina [Department of Analytical Chemistry, Institute of Chemistry, Saint Petersburg State University, RU-198504 Saint Petersburg (Russian Federation); Andruch, Vasil, E-mail: vasil.andruch@upjs.sk [Department of Analytical Chemistry, University of P.J. Šafárik, SK-04154 Košice (Slovakia); Moskvin, Leonid [Department of Analytical Chemistry, Institute of Chemistry, Saint Petersburg State University, RU-198504 Saint Petersburg (Russian Federation); Bulatov, Andrey, E-mail: bulatov_andrey@mail.ru [Department of Analytical Chemistry, Institute of Chemistry, Saint Petersburg State University, RU-198504 Saint Petersburg (Russian Federation)

    2016-01-01

    A first attempt to automate the effervescence assisted dispersive liquid–liquid microextraction (EA-DLLME) has been reported. The method is based on the aspiration of a sample and all required aqueous reagents into the stepwise injection analysis (SWIA) manifold, followed by simultaneous counterflow injection of the extraction solvent (dichloromethane), the mixture of the effervescence agent (0.5 mol L{sup −1} Na{sub 2}CO{sub 3}) and the proton donor solution (1 mol L{sup −1} CH{sub 3}COOH). Formation of carbon dioxide microbubbles generated in situ leads to the dispersion of the extraction solvent in the whole aqueous sample and extraction of the analyte into organic phase. Unlike the conventional DLLME, in the case of EA-DLLME, the addition of dispersive solvent, as well as, time consuming centrifugation step for disruption of the cloudy state is avoided. The phase separation was achieved by gentle bubbling of nitrogen stream (2 mL min{sup −1} during 2 min). The performance of the suggested approach is demonstrated by determination of antipyrine in saliva samples. The procedure is based on the derivatization of antipyrine by nitrite-ion followed by EA-DLLME of 4-nitrosoantipyrine and subsequent UV–Vis detection using SWIA manifold. The absorbance of the yellow-colored extract at the wavelength of 345 nm obeys Beer's law in the range of 1.5–100 µmol L{sup −1} of antipyrine in saliva. The LOD, calculated from a blank test based on 3σ, was 0.5 µmol L{sup −1}. - Highlights: • First attempt to automate the effervescence assisted dispersive liquid–liquid microextraction. • Automation based on Stepwise injection analysis manifold in flow batch system. • Counterflow injection of extraction solvent and the effervescence agent. • Phase separation performed by gentle bubbling of nitrogen. • Application for the determination of antipyrine in saliva samples.

  20. A fully automated effervescence assisted dispersive liquid–liquid microextraction based on a stepwise injection system. Determination of antipyrine in saliva samples

    International Nuclear Information System (INIS)

    Medinskaia, Kseniia; Vakh, Christina; Aseeva, Darina; Andruch, Vasil; Moskvin, Leonid; Bulatov, Andrey

    2016-01-01

    A first attempt to automate the effervescence assisted dispersive liquid–liquid microextraction (EA-DLLME) has been reported. The method is based on the aspiration of a sample and all required aqueous reagents into the stepwise injection analysis (SWIA) manifold, followed by simultaneous counterflow injection of the extraction solvent (dichloromethane), the mixture of the effervescence agent (0.5 mol L"−"1 Na_2CO_3) and the proton donor solution (1 mol L"−"1 CH_3COOH). Formation of carbon dioxide microbubbles generated in situ leads to the dispersion of the extraction solvent in the whole aqueous sample and extraction of the analyte into organic phase. Unlike the conventional DLLME, in the case of EA-DLLME, the addition of dispersive solvent, as well as, time consuming centrifugation step for disruption of the cloudy state is avoided. The phase separation was achieved by gentle bubbling of nitrogen stream (2 mL min"−"1 during 2 min). The performance of the suggested approach is demonstrated by determination of antipyrine in saliva samples. The procedure is based on the derivatization of antipyrine by nitrite-ion followed by EA-DLLME of 4-nitrosoantipyrine and subsequent UV–Vis detection using SWIA manifold. The absorbance of the yellow-colored extract at the wavelength of 345 nm obeys Beer's law in the range of 1.5–100 µmol L"−"1 of antipyrine in saliva. The LOD, calculated from a blank test based on 3σ, was 0.5 µmol L"−"1. - Highlights: • First attempt to automate the effervescence assisted dispersive liquid–liquid microextraction. • Automation based on Stepwise injection analysis manifold in flow batch system. • Counterflow injection of extraction solvent and the effervescence agent. • Phase separation performed by gentle bubbling of nitrogen. • Application for the determination of antipyrine in saliva samples.

  1. Automated evaluation of pharmaceutically active ionic liquids’ (eco)toxicity through the inhibition of human carboxylesterase and Vibrio fischeri

    International Nuclear Information System (INIS)

    Costa, Susana P.F.; Justina, Vanessa D.; Bica, Katharina; Vasiloiu, Maria; Pinto, Paula C.A.G.; Saraiva, M. Lúcia M.F.S.

    2014-01-01

    Highlights: • IL-APIs toxicity on humans and aquatic environment was evaluated by inhibition assays. • The inhibition assays were implemented through automated screening bioassays. • Automation of bioassays enabled a rigorous control of the reaction conditions. • EC 50 obtained provide vital information on IL-APIs safety and potential use as drugs. -- Abstract: The toxicity of 16 pharmaceutical active ionic liquids (IL-APIs) was evaluated by automated approaches based on sequential injection analysis (SIA). The implemented bioassays were centered on the inhibition of human carboxylesterase 2 and Vibrio fischeri, in the presence of the tested compounds. The inhibitory effects were quantified by calculating the inhibitor concentration required to cause 50% of inhibition (EC 50 ). The EC 50 values demonstrated that the cetylpyridinium group was one of the most toxic cations and that the imidazolium group was the less toxic. The obtained results provide important information about the safety of the studied IL-APIs and their possible use as pharmaceutical drugs. The developed automated SIA methodologies are robust screening bioassays, and can be used as a generic tools to identify the (eco)toxicity of the structural elements of ILs, contributing to a sustainable development of drugs

  2. An automatic injection system for rapid radiochemistry

    International Nuclear Information System (INIS)

    Nurmia, M.J.; Kreek, S.A.; Kadkhodayan, B.; Gregorich, K.E.; Lee, D.M.; Hoffman, D.C.

    1992-01-01

    A description is given of the Automated Injection System (AIS), a pneumatically actuated device for automated collection of nuclear reaction products from a He/KCl gas jet transport system. The AIS is used with the Automated Chemical Chromatographic Element Separation System; together these two devices facilitate completely automated separation procedures with improved speed and reproducibility

  3. Fractionation of plutonium in environmental and bio-shielding concrete samples using dynamic sequential extraction

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin

    2010-01-01

    Fractionation of plutonium isotopes (238Pu, 239,240Pu) in environmental samples (i.e. soil and sediment) and bio-shielding concrete from decommissioning of nuclear reactor were carried out by dynamic sequential extraction using an on-line sequential injection (SI) system combined with a specially...

  4. [Studies on a sequential injection renewable surface reflectance spectrophotometric system using a microchip flow cell].

    Science.gov (United States)

    Wang, Jian-ya; Fang, Zhao-lun

    2002-02-01

    A microchip flow cell was developed for flow injection renewable surface assay by reflectance spectrophotometry. The flow cell was coupled to a sequential injection system and optical fiber photometric detection system. The flow cell featured a three-layer structure. The flow channel was cut into a silicone rubber membrance which formed the middle layer, and a porous filter was inlayed across a widened section of the channel to trap microbeads introduced into the flow cell. The area of the detection window of the flow cell was approximately 3.6 mm2, the volume of the bead trapped in the flow cell was 2.2 microL, the depth of the bead layer was 600 microns. A multistrand bifurcated optical fiber was coupled with incident light, detector and flow cell. The chromogenic reaction of Cr(VI) with 1,5-diphenylcarbohydrazide (DPC) which was adsorbed on trapped Polysorb C-18 beads was used as a model reaction to optimize the flow cell design and the experimental system. The reflectance of the renewable reaction surface was monitored at 540 nm. With 100 microL sample loaded and 1.0 mL.min-1 carrier flow rate, the linear response range was 0-0.6 microgram.mL-1 Cr(VI). A detection limit (3 sigma) of 6 ng.mL-1, precision of 1.5% RSD(n = 11), and a throughput of 64 samples per hour were achieved. Considerations in system and flow cell design, the influence of depth of the bead layer, weight of beads used, and the flow rates of carrier stream on the performance were discussed.

  5. Development of an automated flow injection analysis system for determination of phosphate in nutrient solutions.

    Science.gov (United States)

    Karadağ, Sevinç; Görüşük, Emine M; Çetinkaya, Ebru; Deveci, Seda; Dönmez, Koray B; Uncuoğlu, Emre; Doğu, Mustafa

    2018-01-25

    A fully automated flow injection analysis (FIA) system was developed for determination of phosphate ion in nutrient solutions. This newly developed FIA system is a portable, rapid and sensitive measuring instrument that allows on-line analysis and monitoring of phosphate ion concentration in nutrient solutions. The molybdenum blue method, which is widely used in FIA phosphate analysis, was adapted to the developed FIA system. The method is based on the formation of ammonium Mo(VI) ion by reaction of ammonium molybdate with the phosphate ion present in the medium. The Mo(VI) ion then reacts with ascorbic acid and is reduced to the spectrometrically measurable Mo(V) ion. New software specific for flow analysis was developed in the LabVIEW development environment to control all the components of the FIA system. The important factors affecting the analytical signal were identified as reagent flow rate, injection volume and post-injection flow path length, and they were optimized using Box-Behnken experimental design and response surface methodology. The optimum point for the maximum analytical signal was calculated as 0.50 mL min -1 reagent flow rate, 100 µL sample injection volume and 60 cm post-injection flow path length. The proposed FIA system had a sampling frequency of 100 samples per hour over a linear working range of 3-100 mg L -1 (R 2  = 0.9995). The relative standard deviation (RSD) was 1.09% and the limit of detection (LOD) was 0.34 mg L -1 . Various nutrient solutions from a tomato-growing hydroponic greenhouse were analyzed with the developed FIA system and the results were found to be in good agreement with vanadomolybdate chemical method findings. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.

  6. Development of a Sequential Injection Analysis System for the Determination of Saccharin.

    Science.gov (United States)

    Wibowotomo, Budi; Eun, Jong-Bang; Rhee, Jong Il

    2017-12-12

    Saccharin is a powerfully sweet nonnutritive sweetener that has been approved for food-processing applications within the range of 100-1200 mg/kg. A simple, rapid, and cost-effective sequential injection analysis (SIA) technique was developed to determine the saccharin level. This method is based on the reaction of saccharin with p-chloranil in an ethanol medium with a hydrogen peroxide (H₂O₂) acceleration, and the resultant violet-red compound was detected using a UV-Vis spectrophotometer at λ max = 420 nm. To ascertain the optimal conditions for the SIA system, several parameters were investigated, including buffer flow rate and volume, p-chloranil concentration, and reactant volumes (saccharin, p-chloranil, and H₂O₂). The optimum setup of the SIA system was achieved with a buffer flow rate, buffer volume, and draw-up time of 1.2 mL/min, 2900 µL, and ~145 s, respectively. The optimal p-chloranil concentration is 30 mM, and the best reactant volumes, presented in an ordered sequence, are as follows: 30 µL of H₂O₂, 450 µL of saccharin, and 150 µL of p-chloranil. The optimized SIA configuration produced a good linear calibration curve with a correlation coefficient (R² = 0.9812) in the concentration range of 20-140 mg/L and with a detection limit of 19.69 mg/L. Analytical applications in different food categories also showed acceptable recovery values in the range of 93.1-111.5%. This simple and rapid SIA system offers great feasibility for the saccharin quality control in food-product processing.

  7. A novel flow injection chemiluminescence method for automated and miniaturized determination of phenols in smoked food samples.

    Science.gov (United States)

    Vakh, Christina; Evdokimova, Ekaterina; Pochivalov, Aleksei; Moskvin, Leonid; Bulatov, Andrey

    2017-12-15

    An easily performed fully automated and miniaturized flow injection chemiluminescence (CL) method for determination of phenols in smoked food samples has been proposed. This method includes the ultrasound assisted solid-liquid extraction coupled with gas-diffusion separation of phenols from smoked food sample and analytes absorption into a NaOH solution in a specially designed gas-diffusion cell. The flow system was designed to focus on automation and miniaturization with minimal sample and reagent consumption by inexpensive instrumentation. The luminol - N-bromosuccinimide system in an alkaline medium was used for the CL determination of phenols. The limit of detection of the proposed procedure was 3·10 -8 ·molL -1 (0.01mgkg -1 ) in terms of phenol. The presented method demonstrated to be a good tool for easy, rapid and cost-effective point-of-need screening phenols in smoked food samples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Sequential injection redox or acid-base titration for determination of ascorbic acid or acetic acid.

    Science.gov (United States)

    Lenghor, Narong; Jakmunee, Jaroon; Vilen, Michael; Sara, Rolf; Christian, Gary D; Grudpan, Kate

    2002-12-06

    Two sequential injection titration systems with spectrophotometric detection have been developed. The first system for determination of ascorbic acid was based on redox reaction between ascorbic acid and permanganate in an acidic medium and lead to a decrease in color intensity of permanganate, monitored at 525 nm. A linear dependence of peak area obtained with ascorbic acid concentration up to 1200 mg l(-1) was achieved. The relative standard deviation for 11 replicate determinations of 400 mg l(-1) ascorbic acid was 2.9%. The second system, for acetic acid determination, was based on acid-base titration of acetic acid with sodium hydroxide using phenolphthalein as an indicator. The decrease in color intensity of the indicator was proportional to the acid content. A linear calibration graph in the range of 2-8% w v(-1) of acetic acid with a relative standard deviation of 4.8% (5.0% w v(-1) acetic acid, n=11) was obtained. Sample throughputs of 60 h(-1) were achieved for both systems. The systems were successfully applied for the assays of ascorbic acid in vitamin C tablets and acetic acid content in vinegars, respectively.

  9. The application of micro-column solid phase extraction techniques for the determination of rare earth elements in actinide containing matrices

    International Nuclear Information System (INIS)

    Carney, K.P.; Cummings, D.G.

    1995-01-01

    The design and characterization of an argon segmented-solid phase extraction system is described. A 200 ul volume micro-column has been constructed for the preconcentration of rare earth elements (REEs) from salt matrices containing uranium. An inductively coupled plasma atomic emission spectrometer has been utilized for simultaneous detection of Sr, Y and the REEs (namely Ce, Eu, La, Nd, Pr, Sm) at levels ranging from 5- to 2000 ppm in LiCl/KCl samples containing U. Preconcentration factors of 100 fold have been demonstrated. The precision, linear dynamic range and column performance of the system will be presented. (author). 5 refs., 5 figs., 3 tabs

  10. Automated injection of slurry samples in flow-injection analysis

    NARCIS (Netherlands)

    Hulsman, M.H.F.M.; Hulsman, M.; Bos, M.; van der Linden, W.E.

    1996-01-01

    Two types of injectors are described for introducing solid samples as slurries in flow analysis systems. A time-based and a volume-based injector based on multitube solenoid pinch valves were built, both can be characterized as hydrodynamic injectors. Reproducibility of the injections of dispersed

  11. Extraction and preconcentration of trace levels of cobalt using functionalized magnetic nanoparticles in a sequential injection lab-on-valve system with detection by electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Wang Yang; Luo Xiaoyu; Tang Jie; Hu Xiaoya; Xu Qin; Yang Chun

    2012-01-01

    Graphical abstract: An approach to performing extraction and preconcentration employing functionalized magnetic particles for the determination of cobalt in the sequential injection lab-on-valve system using detection by electrothermal atomic absorption spectrometry. Highlights: ► New SPE method for cobalt separation/preconcentration was reported. ► Functionalized magnetic nanoparticles were used as adsorbent. ► Extraction, elution, and detection procedures were performed in the LOV system. ► This automatic extraction technique provided a good platform for metal analysis. - Abstract: A new approach to performing extraction and preconcentration employing functionalized magnetic nanoparticles for the determination of trace metals is presented. Alumina-coated iron oxide nanoparticles were synthesized and used as the solid support. The nanoparticles were functionalized with sodium dodecyl sulfate and used as adsorbents for solid phase extraction of the analyte. Extraction, elution, and detection procedures were performed sequentially in the sequential injection lab-on-valve (SI-LOV) system followed by electrothermal atomic absorption spectrometry (ETAAS). Mixtures of hydrophobic analytes were successfully extracted from solution using the synthesized magnetic adsorbents. The potential use of the established scheme was demonstrated by taking cobalt as a model analyte. Under the optimal conditions, the calibration curve showed an excellent linearity in the concentration range of 0.01–5 μg L −1 , and the relative standard deviation was 2.8% at the 0.5 μg L −1 level (n = 11). The limit of detection was 6 ng L −1 with a sampling frequency of 18 h −1 . The present method has been successfully applied to cobalt determination in water samples and two certified reference materials.

  12. Computer automation and artificial intelligence

    International Nuclear Information System (INIS)

    Hasnain, S.B.

    1992-01-01

    Rapid advances in computing, resulting from micro chip revolution has increased its application manifold particularly for computer automation. Yet the level of automation available, has limited its application to more complex and dynamic systems which require an intelligent computer control. In this paper a review of Artificial intelligence techniques used to augment automation is presented. The current sequential processing approach usually adopted in artificial intelligence has succeeded in emulating the symbolic processing part of intelligence, but the processing power required to get more elusive aspects of intelligence leads towards parallel processing. An overview of parallel processing with emphasis on transputer is also provided. A Fuzzy knowledge based controller for amination drug delivery in muscle relaxant anesthesia on transputer is described. 4 figs. (author)

  13. Simultaneous versus Sequential Intratympanic Steroid Treatment for Severe-to-Profound Sudden Sensorineural Hearing Loss.

    Science.gov (United States)

    Yoo, Myung Hoon; Lim, Won Sub; Park, Joo Hyun; Kwon, Joong Keun; Lee, Tae-Hoon; An, Yong-Hwi; Kim, Young-Jin; Kim, Jong Yang; Lim, Hyun Woo; Park, Hong Ju

    2016-01-01

    Severe-to-profound sudden sensorineural hearing loss (SSNHL) has a poor prognosis. We aimed to compare the efficacy of simultaneous and sequential oral and intratympanic steroids for this condition. Fifty patients with severe-to-profound SSNHL (>70 dB HL) were included from 7 centers. The simultaneous group (27 patients) received oral and intratympanic steroid injections for 2 weeks. The sequential group (23 patients) was treated with oral steroids for 2 weeks and intratympanic steroids for the subsequent 2 weeks. Pure-tone averages (PTA) and word discrimination scores (WDS) were compared before treatment and 2 weeks and 1 and 2 months after treatment. Treatment outcomes according to the modified American Academy of Otolaryngology-Head and Neck Surgery (AAO-HNS) criteria were also analyzed. The improvement in PTA and WDS at the 2-week follow-up was 23 ± 21 dB HL and 20 ± 39% in the simultaneous group and 31 ± 29 dB HL and 37 ± 42% in the sequential group; this was not statistically significant. Complete or partial recovery at the 2-week follow-up was observed in 26% of the simultaneous group and 30% of the sequential group; this was also not significant. The improvement in PTA and WDS at the 2-month follow-up was 40 ± 20 dB HL and 37 ± 35% in the simultaneous group and 41 ± 25 dB HL and 48 ± 41% in the sequential group; this was not statistically significant. Complete or partial recovery at the 2-month follow-up was observed in 33% of the simultaneous group and 35% of the sequential group; this was also not significant. Seven patients in the sequential group did not need intratympanic steroid injections for sufficient improvement after oral steroids alone. Simultaneous oral/intratympanic steroid treatment yielded a recovery similar to that produced by sequential treatment. Because the addition of intratympanic steroids can be decided upon based on the improvement after an oral steroid, the sequential regimen can be recommended to avoid unnecessary

  14. Selective extraction of phospholipids from dairy products by micro-solid phase extraction based on titanium dioxide microcolumns followed by MALDI-TOF-MS analysis

    DEFF Research Database (Denmark)

    Calvano, Cosima; Jensen, Ole; Zambonin, Carlo

    2009-01-01

    A new micro-solid phase extraction (micro-SPE) procedure based on titanium dioxide microcolumns was developed for the selective extraction of phospholipids (PLs) from dairy products before matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) analysis. All...... the extraction steps (loading, washing, and elution) have been optimized using a synthetic mixture of PLs standard and the procedure was subsequently applied to food samples such as milk, chocolate milk and butter. The whole method demonstrated to be simpler than traditional approaches and it appears very...

  15. Highly selective micro-sequential injection lab-on-valve (μSI-LOV) method for determination of ultra trace concentrations of nickel in saline matrices using detection by electrothermal atomic absorption spectrometr

    DEFF Research Database (Denmark)

    Long, Xiangbao; Miró, Manuel; Jensen, Rikard

    2006-01-01

    of the LOV to assure sufficient reaction time for the formation of Ni(DMG)2 chelate. The non-ionic coordination compound is then collected in a renewable micro-column packed with a reversed-phase copolymeric sorbent [namely, poly(divinylbenzene-co-N-vinylpyrrolidone)] containing a balanced ratio...... water of high hardness and local seawater. Satisfying recoveries were achieved for all spiked environmental water samples with maximum deviations of 6%. The experimental results for the standard reference material were not statistically different to the certified value at a significance level of 0.05....

  16. Development of an automated technique for the speciation of arsenic using flow injection hydride generation atomic absorption spectrometry (FI-HG-AAS)

    Energy Technology Data Exchange (ETDEWEB)

    Ruede, T.R. (Inst. of Petrography and Geochemistry, Univ. of Karlsruhe (Germany)); Puchelt, H. (Inst. of Petrography and Geochemistry, Univ. of Karlsruhe (Germany))

    1994-09-01

    An automated method for the determination of arsenic acid (AsV), arsenous acid (AsIII), monomethylarsonic acid (MMAA) and dimethylarsinic acid (DMAA) was developed using a commercial available flow injection hydride generation system. By carrying out the hydride generation in selected acid media the determination of As(III) alone, of MMAA and DMAA by sum and by different sensitivities, and of all four species is possible. (orig.)

  17. Development of a Sequential Injection Analysis System for the Determination of Saccharin

    Directory of Open Access Journals (Sweden)

    Budi Wibowotomo

    2017-12-01

    Full Text Available Saccharin is a powerfully sweet nonnutritive sweetener that has been approved for food-processing applications within the range of 100–1200 mg/kg. A simple, rapid, and cost-effective sequential injection analysis (SIA technique was developed to determine the saccharin level. This method is based on the reaction of saccharin with p-chloranil in an ethanol medium with a hydrogen peroxide (H2O2 acceleration, and the resultant violet-red compound was detected using a UV-Vis spectrophotometer at λmax = 420 nm. To ascertain the optimal conditions for the SIA system, several parameters were investigated, including buffer flow rate and volume, p-chloranil concentration, and reactant volumes (saccharin, p-chloranil, and H2O2. The optimum setup of the SIA system was achieved with a buffer flow rate, buffer volume, and draw-up time of 1.2 mL/min, 2900 µL, and ~145 s, respectively. The optimal p-chloranil concentration is 30 mM, and the best reactant volumes, presented in an ordered sequence, are as follows: 30 µL of H2O2, 450 µL of saccharin, and 150 µL of p-chloranil. The optimized SIA configuration produced a good linear calibration curve with a correlation coefficient (R2 = 0.9812 in the concentration range of 20–140 mg/L and with a detection limit of 19.69 mg/L. Analytical applications in different food categories also showed acceptable recovery values in the range of 93.1–111.5%. This simple and rapid SIA system offers great feasibility for the saccharin quality control in food-product processing.

  18. Automated x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    O'Connell, A.M.

    1977-01-01

    A fully automated x-ray fluorescence analytical system is described. The hardware is based on a Philips PW1220 sequential x-ray spectrometer. Software for on-line analysis of a wide range of sample types has been developed for the Hewlett-Packard 9810A programmable calculator. Routines to test the system hardware are also described. (Author)

  19. Intra-individual diagnostic image quality and organ-specific-radiation dose comparison between spiral cCT with iterative image reconstruction and z-axis automated tube current modulation and sequential cCT

    International Nuclear Information System (INIS)

    Wenz, Holger; Maros, Máté E.; Meyer, Mathias; Gawlitza, Joshua; Förster, Alex; Haubenreisser, Holger; Kurth, Stefan; Schoenberg, Stefan O.; Groden, Christoph; Henzler, Thomas

    2016-01-01

    •Superiority of spiral versus sequential cCT in image quality and organ-specific-radiation dose.•Spiral cCT: lower organ-specific-radiation-dose in eye lense compared to tilted sequential cCT.•State-of-the-art IR spiral cCT techniques has significant advantages over sequential cCT techniques. Superiority of spiral versus sequential cCT in image quality and organ-specific-radiation dose. Spiral cCT: lower organ-specific-radiation-dose in eye lense compared to tilted sequential cCT. State-of-the-art IR spiral cCT techniques has significant advantages over sequential cCT techniques. To prospectively evaluate image quality and organ-specific-radiation dose of spiral cranial CT (cCT) combined with automated tube current modulation (ATCM) and iterative image reconstruction (IR) in comparison to sequential tilted cCT reconstructed with filtered back projection (FBP) without ATCM. 31 patients with a previous performed tilted non-contrast enhanced sequential cCT aquisition on a 4-slice CT system with only FBP reconstruction and no ATCM were prospectively enrolled in this study for a clinical indicated cCT scan. All spiral cCT examinations were performed on a 3rd generation dual-source CT system using ATCM in z-axis direction. Images were reconstructed using both, FBP and IR (level 1–5). A Monte-Carlo-simulation-based analysis was used to compare organ-specific-radiation dose. Subjective image quality for various anatomic structures was evaluated using a 4-point Likert-scale and objective image quality was evaluated by comparing signal-to-noise ratios (SNR). Spiral cCT led to a significantly lower (p < 0.05) organ-specific-radiation dose in all targets including eye lense. Subjective image quality of spiral cCT datasets with an IR reconstruction level 5 was rated significantly higher compared to the sequential cCT acquisitions (p < 0.0001). Consecutive mean SNR was significantly higher in all spiral datasets (FBP, IR 1–5) when compared to sequential cCT with a mean

  20. Automated sequential injection-microcolumn approach with on-line flame atomic absorption spectrometric detection for implementing metal fractionation schemes of homogeneous and non-homogeneous solid samples of environmental interest

    DEFF Research Database (Denmark)

    Chomchoei, Roongrat; Miró, Manuel; Hansen, Elo Harald

    2005-01-01

    spectrometric detection and used for the determination of Cu as a model analyte, the potentials of this novel hyphenated approach are demonstrated by the ability of handling up to 300 mg sample of a nonhomogeneous sewage amended soil (viz., CRM 483). The three steps of the endorsed Standards, Measurements...

  1. Determination of trace metal ions via on-line separation and preconcentration by means of chelating Sepharose beads in a sequential injection lab-on-valve (SI-LOV) system coupled to electrothermal atomic absorption spectrometric detection

    DEFF Research Database (Denmark)

    Long, Xiangbao; Hansen, Elo Harald; Miró, Manuel

    2005-01-01

    The analytical performance of an on-line sequential injection lab-on-valve (SI-LOV) system using chelating Sepharose beads as sorbent material for the determination of ultra trace levels of Cd(II), Pb(II) and Ni(II) by electrothermal atomic absorption spectrometry (ETAAS) is described and discussed...

  2. Cost-Utility of a Single-Injection Combined Corticosteroid-Hyaluronic Acid Formulation vs a 2-Injection Regimen of Sequential Corticosteroid and Hyaluronic Acid Injections.

    Science.gov (United States)

    Belzile, Etienne L; Deakon, Robert T; Vannabouathong, Christopher; Bhandari, Mohit; Lamontagne, Martin; McCormack, Robert

    2017-01-01

    Research has shown early and sustained relief with a combination therapy of a corticosteroid (CS) and hyaluronic acid (HA) in knee osteoarthritis (OA) patients. This can be administered via a single injection containing both products or as separate injections. The former may be more expensive when considering only product cost, but the latter incurs the additional costs and time of a second procedure. The purpose of this study was to compare the cost-utility of the single injection with the 2-injection regimen. The results of this analysis revealed that the single-injection formulation of a CS and HA may be cost-effective, assuming a willingness-to-pay of $50 000 per quality-adjusted life year gained, for symptomatic relief of OA symptoms. This treatment may also be more desirable to patients who find injections to be inconvenient or unpleasant.

  3. Enhanced Silver Nanoparticle Chemiluminescence Method for the Determination of Gemifloxacin Mesylate using Sequential Injection Analysis

    International Nuclear Information System (INIS)

    Alarfaj, N.A.; Aly, F.A.; Tamimi, A.A.

    2013-01-01

    A sequential injection analysis (SIA) with chemiluminescence detection has been proposed for the determination of the antibiotic gemifloxacin mesylate (GFX). The developed method is based on the enhancement effect of silver nanoparticles (Ag NPs) on the chemiluminescence (CL) signal of luminol-potassium ferricyanide reaction in alkaline medium. The introduction of gemifloxacin in this system produced a significant decrease in the CL intensity in presence of (Ag NPs). The optimum conditions for CL emission were investigated. Linear relationship between the decrease in CL intensity and concentration was obtained in the range 0.01-1000 ng mL-1, (r = 0.9997) with detection limit of 2.0 pg mL-1 and quantification limit of 0.01 pg mL-1. The relative standard deviation was 1.3 %. The proposed method was employed for the determination of gemifloxacin in bulk drug, in its pharmaceutical dosage forms and biological fluids such as human serum and urine. The interference of some common additive compounds such as glucose, lactose, starch, talc and magnesium stearate was investigated, and no interference was found from these excipients. The obtained SIA results were statistically compared with those obtained from a reported method and did not show any significant difference at confidence level 95%. (author)

  4. Modified mesoporous silica materials for on-line separation and preconcentration of hexavalent chromium using a microcolumn coupled with flame atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Wang Zheng, E-mail: wangzheng@mail.sic.ac.cn [Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); Fang Dongmei; Li Qing [Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); East China University of Science and Technology, Shanghai 200237 (China); Zhang Lingxia; Qian Rong; Zhu Yan; Qu Haiyun [Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); Du Yiping [East China University of Science and Technology, Shanghai 200237 (China)

    2012-05-06

    Highlights: Black-Right-Pointing-Pointer A modified SBA-15 mesoporous silica material (NH{sub 2}-SBA-15) was synthesized as sorbent. Black-Right-Pointing-Pointer The material was used for the first time in a flow injection on-line solid phase extraction (SPE) coupled with flame atomic absorption spectrometry (FAAS) to detect trace Cr (VI). Black-Right-Pointing-Pointer The NH{sub 2}-SBA-15 enables retain Cr (VI) with an enrichment factor of 44. Black-Right-Pointing-Pointer The micro-column of NH{sub 2}-SBA-15 underwent more than 100 adsorption/desorption cycles. - Abstract: A modified SBA-15 mesoporous silica material NH{sub 2}-SBA-15 was synthesized successfully by grafting {gamma}-aminopropyl-triethoxysilane. The material was characterized using transmission electron microscopy (TEM) and Fourier transform infrared/Raman (FT-IR/Raman) spectroscopy, and used for the first time in a flow injection on-line solid phase extraction (SPE) coupled with flame atomic absorption spectrometry (FAAS) to detect trace Cr (VI). Effective sorption of Cr (VI) was achieved at pH 2.0 with no interference from Cr (III) and other ions and 0.5 mol L{sup -1} NH{sub 3}{center_dot}H{sub 2}O solution was found optimal for the complete elution of Cr (VI). An enrichment factor of 44 and was achieved under optimized experimental conditions at a sample loading of 2.0 mL min{sup -1} sample loading (300 s) and an elution flow rate of 2.0 mL min{sup -1} (24 s). The precision of the 11 replicate Cr (VI) measurements was 2.1% at the 100 {mu}g L{sup -1} level with a detection limit of 0.2 {mu}g L{sup -1} (3 s, n = 10) using the FAAS. The developed method was successfully applied to trace chromium determination in waste water. The accuracy was validated using a certified reference material of riverine water (GBW08607).

  5. An automated wavelength selection for flame spectroscopy

    International Nuclear Information System (INIS)

    Hurteau, M.; Mislan, J.P.; Ashley, R.W.

    1976-01-01

    A simple electro-mechanical programming system is described for use with a flame spectrophotometer. Its application for automated sequential multi-element analysis is illustrated. Reproducibility of wavelength settings are within +-0.5 A. Precision and sensitivities are at least as good as those obtained for single element determinations. (author)

  6. Development and application of an on-line sequential injection system for the separation of artificial and natural radionuclides in environmental samples

    International Nuclear Information System (INIS)

    Kim, C.-K.; Sansone, U.; Martin, P.; Kim, C.-S.

    2007-02-01

    The Chemistry Unit of the Physics, Chemistry and Instrumentation Laboratory in the IAEA's Seibersdorf Laboratory in Austria, has the programmatic responsibility to provide assistance to Member State laboratories in maintaining and improving the reliability of analytical measurement results, both in trace element and radionuclide determinations. This is accomplished through the provision of reference materials of terrestrial origin, validated analytical procedures, training in the implementation of internal quality control, and through the evaluation of measurement performance by organization of worldwide and regional interlaboratory comparison exercises. In this framework an on-line sequential injection (SI) system was developed, which can be widely used for the separation and preconcentration of target analytes from diverse environmental samples. The system enables the separation time to be shortened by maintaining a constant flow rate of solution and by avoiding clogging or bubbling in a chromatographic column. The SI system was successfully applied to the separation of Pu in IAEA reference material (IAEA Soil-6) and to the sequential separation of 210 Po and 210 Pb in phosphogypsum candidate reference material. The replicate analysis results of Pu in IAEA reference material (Soil-6) obtained with the SI system are in good agreement with the recommended value within 5% of standard deviation. The SI system enabled a halving in the separation time required for of radionuclides

  7. Amperometric Determination of Sulfite by Gas Diffusion- Sequential Injection with Boron-Doped Diamond Electrode

    Directory of Open Access Journals (Sweden)

    Orawon Chailapakul

    2008-03-01

    Full Text Available A gas diffusion sequential injection system with amperometric detection using aboron-doped diamond electrode was developed for the determination of sulfite. A gasdiffusion unit (GDU was used to prevent interference from sample matrices for theelectrochemical measurement. The sample was mixed with an acid solution to generategaseous sulfur dioxide prior to its passage through the donor channel of the GDU. Thesulfur dioxide diffused through the PTFE hydrophobic membrane into a carrier solution of 0.1 M phosphate buffer (pH 8/0.1% sodium dodecyl sulfate in the acceptor channel of theGDU and turned to sulfite. Then the sulfite was carried to the electrochemical flow cell anddetected directly by amperometry using the boron-doped diamond electrode at 0.95 V(versus Ag/AgCl. Sodium dodecyl sulfate was added to the carrier solution to preventelectrode fouling. This method was applicable in the concentration range of 0.2-20 mgSO32−/L and a detection limit (S/N = 3 of 0.05 mg SO32−/L was achieved. This method wassuccessfully applied to the determination of sulfite in wines and the analytical resultsagreed well with those obtained by iodimetric titration. The relative standard deviations forthe analysis of sulfite in wines were in the range of 1.0-4.1 %. The sampling frequency was65 h−1.

  8. Arrays of 3D micro-columns generated by laser ablation of Ta and steel: modelling of a black body emitter

    Energy Technology Data Exchange (ETDEWEB)

    Bensaoula, A.; Boney, C.; Pillai, R.; Starikov, D. [Texas Center for Superconductivity and Advanced Materials, University of Houston, Houston, TX (United States); Shafeev, G.A.; Simakin, A.V. [Wave Research Center, General Physics Institute of the Russian Academy of Sciences, 38, Vavilov Street, 119991, Moscow (Russian Federation)

    2004-09-01

    Three-dimensional extended arrays of micro-columns are generated on the surface of Ta and several stainless steels by their ablation by radiation of a Cu vapor laser either in vacuum or in air. The reflectivity of the arrays is tested in both visible and near-IR regions using the facilities at NASA Johnson Space Center. The reflectivity of the laser-treated areas was found to be very low (0.03-0.08) in the range 250-2800 nm. The emissivity of 3D arrays measured at elevated temperatures is close to the emissivity of a calibrated black body emitter. The effects of the experimental conditions of ablation (laser fluence, environment, etc.) on the integral optical characteristics of the generated arrays are discussed. (orig.)

  9. Dynamic leaching and fractionation of trace elements from environmental solids exploiting a novel circulating-flow platform.

    Science.gov (United States)

    Mori, Masanobu; Nakano, Koji; Sasaki, Masaya; Shinozaki, Haruka; Suzuki, Shiho; Okawara, Chitose; Miró, Manuel; Itabashi, Hideyuki

    2016-02-01

    A dynamic flow-through microcolumn extraction system based on extractant re-circulation is herein proposed as a novel analytical approach for simplification of bioaccessibility tests of trace elements in sediments. On-line metal leaching is undertaken in the format of all injection (AI) analysis, which is a sequel of flow injection analysis, but involving extraction under steady-state conditions. The minimum circulation times and flow rates required to determine the maximum bioaccessible pools of target metals (viz., Cu, Zn, Cd, and Pb) from lake and river sediment samples were estimated using Tessier's sequential extraction scheme and an acid single extraction test. The on-line AIA method was successfully validated by mass balance studies of CRM and real sediment samples. Tessier's test in on-line AI format demonstrated to be carried out by one third of extraction time (6h against more than 17 h by the conventional method), with better analytical precision (15% by the conventional method) and significant decrease in blank readouts as compared with the manual batch counterpart. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Sequential injection of domain walls into ferroelectrics at different bias voltages: Paving the way for “domain wall memristors”

    Energy Technology Data Exchange (ETDEWEB)

    Whyte, J. R.; McQuaid, R. G. P.; Einsle, J. F.; Gregg, J. M., E-mail: m.gregg@qub.ac.uk [Centre for Nanostructured Media (CNM), School of Maths and Physics, Queen' s University Belfast, University Road, Belfast BT7 1NN (United Kingdom); Ashcroft, C. M. [Centre for Nanostructured Media (CNM), School of Maths and Physics, Queen' s University Belfast, University Road, Belfast BT7 1NN (United Kingdom); Department of Physics, Cavendish Laboratory, J. J. Thomson Avenue, Cambridge CB3 0HE (United Kingdom); Canalias, C. [Department of Applied Physics, Royal Institute of Technology, Roslagstullsbacken 21, 10691 Stockholm (Sweden); Gruverman, A. [Department of Physics and Astronomy, University of Nebraska Lincoln, Nebraska 68588–0299 (United States)

    2014-08-14

    Simple meso-scale capacitor structures have been made by incorporating thin (∼300 nm) single crystal lamellae of KTiOPO{sub 4} (KTP) between two coplanar Pt electrodes. The influence that either patterned protrusions in the electrodes or focused ion beam milled holes in the KTP have on the nucleation of reverse domains during switching was mapped using piezoresponse force microscopy imaging. The objective was to assess whether or not variations in the magnitude of field enhancement at localised “hot-spots,” caused by such patterning, could be used to both control the exact locations and bias voltages at which nucleation events occurred. It was found that both the patterning of electrodes and the milling of various hole geometries into the KTP could allow controlled sequential injection of domain wall pairs at different bias voltages; this capability could have implications for the design and operation of domain wall electronic devices, such as memristors, in the future.

  11. A system for accurate and automated injection of hyperpolarized substrate with minimal dead time and scalable volumes over a large range

    Science.gov (United States)

    Reynolds, Steven; Bucur, Adriana; Port, Michael; Alizadeh, Tooba; Kazan, Samira M.; Tozer, Gillian M.; Paley, Martyn N. J.

    2014-02-01

    Over recent years hyperpolarization by dissolution dynamic nuclear polarization has become an established technique for studying metabolism in vivo in animal models. Temporal signal plots obtained from the injected metabolite and daughter products, e.g. pyruvate and lactate, can be fitted to compartmental models to estimate kinetic rate constants. Modeling and physiological parameter estimation can be made more robust by consistent and reproducible injections through automation. An injection system previously developed by us was limited in the injectable volume to between 0.6 and 2.4 ml and injection was delayed due to a required syringe filling step. An improved MR-compatible injector system has been developed that measures the pH of injected substrate, uses flow control to reduce dead volume within the injection cannula and can be operated over a larger volume range. The delay time to injection has been minimized by removing the syringe filling step by use of a peristaltic pump. For 100 μl to 10.000 ml, the volume range typically used for mice to rabbits, the average delivered volume was 97.8% of the demand volume. The standard deviation of delivered volumes was 7 μl for 100 μl and 20 μl for 10.000 ml demand volumes (mean S.D. was 9 ul in this range). In three repeat injections through a fixed 0.96 mm O.D. tube the coefficient of variation for the area under the curve was 2%. For in vivo injections of hyperpolarized pyruvate in tumor-bearing rats, signal was first detected in the input femoral vein cannula at 3-4 s post-injection trigger signal and at 9-12 s in tumor tissue. The pH of the injected pyruvate was 7.1 ± 0.3 (mean ± S.D., n = 10). For small injection volumes, e.g. less than 100 μl, the internal diameter of the tubing contained within the peristaltic pump could be reduced to improve accuracy. Larger injection volumes are limited only by the size of the receiving vessel connected to the pump.

  12. Parallelize Automated Tests in a Build and Test Environment

    OpenAIRE

    Durairaj, Selva Ganesh

    2016-01-01

    This thesis investigates the possibilities of finding solutions, in order to reduce the total time spent for testing and waiting times for running multiple automated test cases in a test framework. The “Automated Test Framework”, developed by Axis Communications AB, is used to write the functional tests to test both hardware and software of a resource. The functional tests that tests the software is considered in this thesis work. In the current infrastructure, tests are executed sequentially...

  13. Elimination of water pathogens with solar radiation using an automated sequential batch CPC reactor

    International Nuclear Information System (INIS)

    Polo-López, M.I.; Fernández-Ibáñez, P.; Ubomba-Jaswa, E.; Navntoft, C.; García-Fernández, I.; Dunlop, P.S.M.; Schmid, M.; Byrne, J.A.

    2011-01-01

    Solar disinfection (SODIS) of water is a well-known, effective treatment process which is practiced at household level in many developing countries. However, this process is limited by the small volume treated and there is no indication of treatment efficacy for the user. Low cost glass tube reactors, together with compound parabolic collector (CPC) technology, have been shown to significantly increase the efficiency of solar disinfection. However, these reactors still require user input to control each batch SODIS process and there is no feedback that the process is complete. Automatic operation of the batch SODIS process, controlled by UVA-radiation sensors, can provide information on the status of the process, can ensure the required UVA dose to achieve complete disinfection is received and reduces user work-load through automatic sequential batch processing. In this work, an enhanced CPC photo-reactor with a concentration factor of 1.89 was developed. The apparatus was automated to achieve exposure to a pre-determined UVA dose. Treated water was automatically dispensed into a reservoir tank. The reactor was tested using Escherichia coli as a model pathogen in natural well water. A 6-log inactivation of E. coli was achieved following exposure to the minimum uninterrupted lethal UVA dose. The enhanced reactor decreased the exposure time required to achieve the lethal UVA dose, in comparison to a CPC system with a concentration factor of 1.0. Doubling the lethal UVA dose prevented the need for a period of post-exposure dark inactivation and reduced the overall treatment time. Using this reactor, SODIS can be automatically carried out at an affordable cost, with reduced exposure time and minimal user input.

  14. Elimination of water pathogens with solar radiation using an automated sequential batch CPC reactor

    Energy Technology Data Exchange (ETDEWEB)

    Polo-Lopez, M.I., E-mail: mpolo@psa.es [Plataforma Solar de Almeria - CIEMAT, PO Box 22, 04200 Tabernas, Almeria (Spain); Fernandez-Ibanez, P., E-mail: pilar.fernandez@psa.es [Plataforma Solar de Almeria - CIEMAT, PO Box 22, 04200 Tabernas, Almeria (Spain); Ubomba-Jaswa, E., E-mail: euniceubombajaswa@yahoo.com [Natural Resources and the Environment, CSIR, PO Box 395, Pretoria (South Africa); Navntoft, C., E-mail: christian.navntoft@solarmate.com.ar [Instituto de Investigacion e Ingenieria Ambiental, Universidad Nacional de San Martin (3iA-UNSAM), Peatonal Belgrano 3563, B1650ANQ San Martin (Argentina); Universidad Tecnologica Nacional - Facultad Regional Buenos Aires - Departamento de Ingenieria Civil - Laboratorio de Estudios sobre Energia Solar, (UTN-FRBA-LESES), Mozart 2300, (1407) Ciudad Autonoma de Buenos Aires, Republica Argentina (Argentina); Garcia-Fernandez, I., E-mail: irene.garcia@psa.es [Plataforma Solar de Almeria - CIEMAT, PO Box 22, 04200 Tabernas, Almeria (Spain); Dunlop, P.S.M., E-mail: psm.dunlop@ulster.ac.uk [Department of Physiology and Medical Physics, Royal College of Surgeons in Ireland, Dublin 2 (Ireland); Schmid, M. [Department of Physiology and Medical Physics, Royal College of Surgeons in Ireland, Dublin 2 (Ireland); Byrne, J.A., E-mail: j.byrne@ulster.ac.uk [Department of Physiology and Medical Physics, Royal College of Surgeons in Ireland, Dublin 2 (Ireland); and others

    2011-11-30

    Solar disinfection (SODIS) of water is a well-known, effective treatment process which is practiced at household level in many developing countries. However, this process is limited by the small volume treated and there is no indication of treatment efficacy for the user. Low cost glass tube reactors, together with compound parabolic collector (CPC) technology, have been shown to significantly increase the efficiency of solar disinfection. However, these reactors still require user input to control each batch SODIS process and there is no feedback that the process is complete. Automatic operation of the batch SODIS process, controlled by UVA-radiation sensors, can provide information on the status of the process, can ensure the required UVA dose to achieve complete disinfection is received and reduces user work-load through automatic sequential batch processing. In this work, an enhanced CPC photo-reactor with a concentration factor of 1.89 was developed. The apparatus was automated to achieve exposure to a pre-determined UVA dose. Treated water was automatically dispensed into a reservoir tank. The reactor was tested using Escherichia coli as a model pathogen in natural well water. A 6-log inactivation of E. coli was achieved following exposure to the minimum uninterrupted lethal UVA dose. The enhanced reactor decreased the exposure time required to achieve the lethal UVA dose, in comparison to a CPC system with a concentration factor of 1.0. Doubling the lethal UVA dose prevented the need for a period of post-exposure dark inactivation and reduced the overall treatment time. Using this reactor, SODIS can be automatically carried out at an affordable cost, with reduced exposure time and minimal user input.

  15. Sequential injection chromatography with post-column reaction/derivatization for the determination of transition metal cations in natural water samples.

    Science.gov (United States)

    Horstkotte, Burkhard; Jarošová, Patrícia; Chocholouš, Petr; Sklenářová, Hana; Solich, Petr

    2015-05-01

    In this work, the applicability of Sequential Injection Chromatography for the determination of transition metals in water is evaluated for the separation of copper(II), zinc(II), and iron(II) cations. Separations were performed using a Dionex IonPAC™ guard column (50mm×2mm i.d., 9 µm). Mobile phase composition and post-column reaction were optimized by modified SIMPLEX method with subsequent study of the concentration of each component. The mobile phase consisted of 2,6-pyridinedicarboxylic acid as analyte-selective compound, sodium sulfate, and formic acid/sodium formate buffer. Post-column addition of 4-(2-pyridylazo)resorcinol was carried out for spectrophotometric detection of the analytes׳ complexes at 530nm. Approaches to achieve higher robustness, baseline stability, and detection sensitivity by on-column stacking of the analytes and initial gradient implementation as well as air-cushion pressure damping for post-column reagent addition were studied. The method allowed the rapid separation of copper(II), zinc(II), and iron(II) within 6.5min including pump refilling and aspiration of sample and 1mmol HNO3 for analyte stacking on the separation column. High sensitivity was achieved applying an injection volume of up to 90µL. A signal repeatability of<2% RSD of peak height was found. Analyte recovery evaluated by spiking of different natural water samples was well suited for routine analysis with sub-micromolar limits of detection. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Highly efficient proteome analysis with combination of protein pre-fractionation by preparative microscale solution isoelectric focusing and identification by μRPLC-MS/MS with serially coupled long microcolumn.

    Science.gov (United States)

    Tao, Dingyin; Sun, Liangliang; Zhu, Guijie; Liang, Yu; Liang, Zhen; Zhang, Lihua; Zhang, Yukui

    2011-01-01

    To improve the efficiency of proteome analysis, a strategy with the combination of protein pre-fractionation by preparative microscale solution isoelectric focusing, peptide separation by μRPLC with serially coupled long microcolumn and protein identification by ESI-MS/MS was proposed. By preparative microscale solution isoelectric focusing technique, proteins extracted from whole cell lysates of Escherichia coli were fractionated into five chambers divided by isoelectric membranes, respectively with pH range from 3.0 to 4.6, 4.6 to 5.4, 5.4 to 6.2, 6.2 to 7.0 and 7.0 to 10.0. Compared to the traditional on-gel IFF, the protein recovery could be obviously improved to over 95%. Subsequently, the enriched and fractionated proteins in each chamber were digested, and further separated by a 30-cm long serially coupled RP microcolumn. Through the detection by ESI-MS/MS, about 200 proteins were identified in each fraction, and in total 835 proteins were identified even with one-dimensional μRPLC-MS/MS system. All these results demonstrate that by such a combination strategy, highly efficient proteome analysis could be achieved, not only due to the in-solution protein enrichment and pre-fractionation with improved protein recovery but also owing to the increased separation capacity of serially coupled long μRPLC columns. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Micro-Columnated Loop Heat Pipe: The Future of Electronic Substrates

    Science.gov (United States)

    Dhillon, Navdeep Singh

    The modern world is run by semiconductor-based electronic systems. Due to continuous improvements in semiconductor device fabrication, there is a clear trend in the market towards the development of electronic devices and components that not only deliver enhanced computing power, but are also more compact. Thermal management has emerged as the primary challenge in this scenario where heat flux dissipation of electronic chips is increasing exponentially, but conventional cooling solutions such as conduction and convection are no longer feasible. To keep device junction temperatures within the safe operating limit, there is an urgent requirement for ultra-high-conductivity thermal substrates that not only absorb and transport large heat fluxes, but can also provide localized cooling to thermal hotspots. This dissertation describes the design, modeling, and fabrication of a phase change-based, planar, ultra-thin, passive thermal transport system that is inspired by the concept of loop heat pipes and capillary pumped loops. Fabricated on silicon and Pyrex wafers using microfabrication techniques, the micro-columnated loop heat pipe (muCLHP) can be integrated directly with densely packed or multiply-stacked electronic substrates, to provide localized high-heat-flux thermal management. The muCLHP employs a dual-scale coherent porous silicon(CPS)-based micro-columnated wicking structure, where the primary CPS wick provides large capillary forces for fluid transport, while a secondary surface-wick maximizes the rate of thin-film evaporation. To overcome the wick thickness limitation encountered in conventional loop heat pipes, strategies based on MEMS surface micromachining techniques were developed to reduce parasitic heat flow from the evaporator to the compensation chamber of the device. Finite element analysis was used to confirm this reduction in a planar evaporator design, thus enabling the generation of a large motive temperature head for continuous device operation

  18. Sequential automated fusion/extraction chromatography methodology for the dissolution of uranium in environmental samples for mass spectrometric determination

    Energy Technology Data Exchange (ETDEWEB)

    Milliard, Alex; Durand-Jezequel, Myriam [Laboratoire de Radioecologie, Departement de chimie, Universite Laval, 1045 Avenue de la Medecine, Quebec, QC, G1V 0A6 (Canada); Lariviere, Dominic, E-mail: dominic.lariviere@chm.ulaval.ca [Laboratoire de Radioecologie, Departement de chimie, Universite Laval, 1045 Avenue de la Medecine, Quebec, QC, G1V 0A6 (Canada)

    2011-01-17

    An improved methodology has been developed, based on dissolution by automated fusion followed by extraction chromatography for the detection and quantification of uranium in environmental matrices by mass spectrometry. A rapid fusion protocol (<8 min) was investigated for the complete dissolution of various samples. It could be preceded, if required, by an effective ashing procedure using the M4 fluxer and a newly designed platinum lid. Complete dissolution of the sample was observed and measured using standard reference materials (SRMs) and experimental data show no evidence of cross-contamination of crucibles when LiBO{sub 2}/LiBr melts were used. The use of a M4 fusion unit also improved repeatability in sample preparation over muffle furnace fusion. Instrumental issues originating from the presence of high salt concentrations in the digestate after lithium metaborate fusion was also mitigated using an extraction chromatography (EXC) protocol aimed at removing lithium and interfering matrix constituants prior to the elution of uranium. The sequential methodology, which can be performed simultaneously on three samples, requires less than 20 min per sample for fusion and separation. It was successfully coupled to inductively coupled plasma mass spectrometry (ICP-MS) achieving detection limits below 100 pg kg{sup -1} for 5-300 mg of sample.

  19. Mass spectrometric protein characterization in proteome analysis using GELoader tip micro-columns packed with various chromatographic material

    International Nuclear Information System (INIS)

    Larsen, M.R.

    2001-01-01

    In the early 90'ies mass spectrometry (MS) was introduced as a tool for identifying proteins in protein sequence databases. Since then it has become an integrated tool in protein characterization and is today routinely used to identify proteins separated by gel electrophoresis. A two-tiered mass spectrometric protein identification strategy has recently been proposed. In the first strategy peptide mass maps obtained from the protein of interest are compared with theoretically derived peptide mass maps from proteins in protein sequence databases. If the protein cannot be identified by this strategy, tandem mass spectrometric sequencing is used to generate enough sequence data to identify the protein in protein sequence databases or expressed sequence tag (EST) databases. However, the above strategies primarily identify a protein relatively to the DNA sequence, in which no information about e.g. post-translational modifications (PTMs) is stored. PTMs are known to modify the function, location, solubility and activity of proteins in the cell, and they are therefore very important for understanding living cells. More than 200 different PTMs are known, of which glycosylation, phosphorylation and proteolytic processing are the most common ones. Mass spectrometric analysis of PTMs on gel-separated proteins requires a higher amount of protein than for identification only. In addition, higher sequence coverage from the peptide mass maps or pre-purification of the modified peptides prior to MS analysis, is necessary for detection of putative modified peptides. In this study a multi-tiered strategy, in which GELoader tip micro-columns packed with increasingly more hydrophobic chromatographic material are used in combination with mass spectrometry, is described. The ultimate aim was to gain increased sequence coverage from peptide mixtures derived from gel-separated proteins, in order to locate modified peptides. Graphite powder is described as an alternative to traditional

  20. Elimination of water pathogens with solar radiation using an automated sequential batch CPC reactor.

    Science.gov (United States)

    Polo-López, M I; Fernández-Ibáñez, P; Ubomba-Jaswa, E; Navntoft, C; García-Fernández, I; Dunlop, P S M; Schmid, M; Byrne, J A; McGuigan, K G

    2011-11-30

    Solar disinfection (SODIS) of water is a well-known, effective treatment process which is practiced at household level in many developing countries. However, this process is limited by the small volume treated and there is no indication of treatment efficacy for the user. Low cost glass tube reactors, together with compound parabolic collector (CPC) technology, have been shown to significantly increase the efficiency of solar disinfection. However, these reactors still require user input to control each batch SODIS process and there is no feedback that the process is complete. Automatic operation of the batch SODIS process, controlled by UVA-radiation sensors, can provide information on the status of the process, can ensure the required UVA dose to achieve complete disinfection is received and reduces user work-load through automatic sequential batch processing. In this work, an enhanced CPC photo-reactor with a concentration factor of 1.89 was developed. The apparatus was automated to achieve exposure to a pre-determined UVA dose. Treated water was automatically dispensed into a reservoir tank. The reactor was tested using Escherichia coli as a model pathogen in natural well water. A 6-log inactivation of E. coli was achieved following exposure to the minimum uninterrupted lethal UVA dose. The enhanced reactor decreased the exposure time required to achieve the lethal UVA dose, in comparison to a CPC system with a concentration factor of 1.0. Doubling the lethal UVA dose prevented the need for a period of post-exposure dark inactivation and reduced the overall treatment time. Using this reactor, SODIS can be automatically carried out at an affordable cost, with reduced exposure time and minimal user input. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Sequential determination of multi-nutrient elements in natural water samples with a reverse flow injection system.

    Science.gov (United States)

    Lin, Kunning; Ma, Jian; Yuan, Dongxing; Feng, Sichao; Su, Haitao; Huang, Yongming; Shangguan, Qipei

    2017-05-15

    An integrated system was developed for automatic and sequential determination of NO 2 - , NO 3 - , PO 4 3- , Fe 2+ , Fe 3+ and Mn 2+ in natural waters based on reverse flow injection analysis combined with spectrophotometric detection. The system operation was controlled by a single chip microcomputer and laboratory-programmed software written in LabVIEW. The experimental parameters for each nutrient element analysis were optimized based on a univariate experimental design, and interferences from common ions were evaluated. The upper limits of the linear range (along with detection limit, µmolL -1 ) of the proposed method was 20 (0.03), 200 (0.7), 12 (0.3), 5 (0.03), 5 (0.03), 9 (0.2) µmolL -1 , for NO 2 - , NO 3 - , PO 4 3- , Fe 2+ , Fe 3+ and Mn 2+ , respectively. The relative standard deviations were below 5% (n=9-13) and the recoveries varied from 88.0±1.0% to 104.5±1.0% for spiked water samples. The sample throughput was about 20h -1 . This system has been successfully applied for the determination of multi-nutrient elements in different kinds of water samples and showed good agreement with reference methods (slope 1.0260±0.0043, R 2 =0.9991, n=50). Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Conceptual design and implementation of Pulse Automation and Scheduling System for KSTAR

    International Nuclear Information System (INIS)

    Lee, Woongryol; Lee, Taegu; Park, Jinseop; Hong, Jaesic; Hahn, Sanghee; Han, Hyunsun; Woo, Minho; Park, Kaprai

    2015-01-01

    Highlights: • The world clock based automatic sequential operation manipulator. • Configuration of the Pulse Automation System (PAS) and the Pulse Scheduling System (PSS) • Providing of operational information in voice through an Ethernet interface. • A perceptional operation status, easy time manipulator, and intuitive man machine interface for the purpose of the Tokamak operation. • Generation of the plasma disruption information. - Abstract: The world clock based automatic sequential operation manipulator has been developed and begin to work on the 7th campaign in KSTAR Tokamak. The Pulse Automation and Scheduling System (PASS) divided into Pulse Automation System (PAS) and Pulse Scheduling System (PSS). The PAS is on the online control system and it has communicated with many other local control systems. Before PASS, the plasma experiment was performed manually by using Central Control System (CCS). However the PASS currently manipulates the sequential operation of KSTAR with the programmed shot interval time. It provides readiness check routine, shot time handler, and local system monitoring functions. The PASS has no hardware dependency and it was configured with EPICS extensions. The Real Time Monitoring System, PCS-GATE, Automatic Reporting System, Central Control System, and Timing Synchronization System are well organized and they communicate to each other. The PASS provides perceptual operation status, easy time manipulator, and intuitive man machine interface. The plasma disruption information which is used in the KSTAR standard software framework also comes from the PASS. We describe the functions and system architecture of the Pulse Automation System in this paper. The PSS will be specified inside PASS for the purpose of intelligent system parameterization.

  3. Conceptual design and implementation of Pulse Automation and Scheduling System for KSTAR

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Woongryol, E-mail: wrlee@nfri.re.kr; Lee, Taegu; Park, Jinseop; Hong, Jaesic; Hahn, Sanghee; Han, Hyunsun; Woo, Minho; Park, Kaprai

    2015-10-15

    Highlights: • The world clock based automatic sequential operation manipulator. • Configuration of the Pulse Automation System (PAS) and the Pulse Scheduling System (PSS) • Providing of operational information in voice through an Ethernet interface. • A perceptional operation status, easy time manipulator, and intuitive man machine interface for the purpose of the Tokamak operation. • Generation of the plasma disruption information. - Abstract: The world clock based automatic sequential operation manipulator has been developed and begin to work on the 7th campaign in KSTAR Tokamak. The Pulse Automation and Scheduling System (PASS) divided into Pulse Automation System (PAS) and Pulse Scheduling System (PSS). The PAS is on the online control system and it has communicated with many other local control systems. Before PASS, the plasma experiment was performed manually by using Central Control System (CCS). However the PASS currently manipulates the sequential operation of KSTAR with the programmed shot interval time. It provides readiness check routine, shot time handler, and local system monitoring functions. The PASS has no hardware dependency and it was configured with EPICS extensions. The Real Time Monitoring System, PCS-GATE, Automatic Reporting System, Central Control System, and Timing Synchronization System are well organized and they communicate to each other. The PASS provides perceptual operation status, easy time manipulator, and intuitive man machine interface. The plasma disruption information which is used in the KSTAR standard software framework also comes from the PASS. We describe the functions and system architecture of the Pulse Automation System in this paper. The PSS will be specified inside PASS for the purpose of intelligent system parameterization.

  4. An Intelligent Automation Platform for Rapid Bioprocess Design.

    Science.gov (United States)

    Wu, Tianyi; Zhou, Yuhong

    2014-08-01

    Bioprocess development is very labor intensive, requiring many experiments to characterize each unit operation in the process sequence to achieve product safety and process efficiency. Recent advances in microscale biochemical engineering have led to automated experimentation. A process design workflow is implemented sequentially in which (1) a liquid-handling system performs high-throughput wet lab experiments, (2) standalone analysis devices detect the data, and (3) specific software is used for data analysis and experiment design given the user's inputs. We report an intelligent automation platform that integrates these three activities to enhance the efficiency of such a workflow. A multiagent intelligent architecture has been developed incorporating agent communication to perform the tasks automatically. The key contribution of this work is the automation of data analysis and experiment design and also the ability to generate scripts to run the experiments automatically, allowing the elimination of human involvement. A first-generation prototype has been established and demonstrated through lysozyme precipitation process design. All procedures in the case study have been fully automated through an intelligent automation platform. The realization of automated data analysis and experiment design, and automated script programming for experimental procedures has the potential to increase lab productivity. © 2013 Society for Laboratory Automation and Screening.

  5. Multi-column step-gradient chromatography system for automated ion exchange separations

    International Nuclear Information System (INIS)

    Rucker, T.L.

    1985-01-01

    A multi-column step-gradient chromatography system has been designed to perform automated sequential separations of radionuclides by ion exchange chromatography. The system consists of a digital programmer with automatic stream selection valve, two peristaltic pumps, ten columns, and a fraction collector. The automation allows complicated separations of radionuclides to be made with minimal analyst attention and allows for increased productivity and reduced cost of analyses. Results are reported for test separations on mixtures of radionuclides by the system

  6. Double tracer autoradiographic method for sequential evaluation of regional cerebral perfusion

    International Nuclear Information System (INIS)

    Matsuda, H.; Tsuji, S.; Oba, H.; Kinuya, K.; Terada, H.; Sumiya, H.; Shiba, K.; Mori, H.; Hisada, K.; Maeda, T.

    1989-01-01

    A new double tracer autoradiographic method for the sequential evaluation of altered regional cerebral perfusion in the same animal is presented. This method is based on the sequential injection of two tracers, 99m Tc-hexamethylpropyleneamine oxime and N-isopropyl-( 125 I)p-iodoamphetamine. This method is validated in the assessment of brovincamine effects on regional cerebral perfusion in an experimental model of chronic brain ischemia in the rat. The drug enhanced perfusion recovery in low-flow areas, selectively in surrounding areas of infarction. The results suggest that this technique is of potential use in the study of neuropharmacological effects applied during the experiment

  7. Comparison of first pass bolus AIFs extracted from sequential 18F-FDG PET and DSC-MRI of mice

    International Nuclear Information System (INIS)

    Evans, Eleanor; Sawiak, Stephen J.; Ward, Alexander O.; Buonincontri, Guido; Hawkes, Robert C.; Adrian Carpenter, T.

    2014-01-01

    Accurate kinetic modelling of in vivo physiological function using positron emission tomography (PET) requires determination of the tracer time–activity curve in plasma, known as the arterial input function (AIF). The AIF is usually determined by invasive blood sampling methods, which are prohibitive in murine studies due to low total blood volumes. Extracting AIFs from PET images is also challenging due to large partial volume effects (PVE). We hypothesise that in combined PET with magnetic resonance imaging (PET/MR), a co-injected bolus of MR contrast agent and PET ligand can be tracked using fast MR acquisitions. This protocol would allow extraction of a MR AIF from MR contrast agent concentration–time curves, at higher spatial and temporal resolution than an image-derived PET AIF. A conversion factor could then be applied to the MR AIF for use in PET kinetic analysis. This work has compared AIFs obtained from sequential DSC-MRI and PET with separate injections of gadolinium contrast agent and 18 F-FDG respectively to ascertain the technique′s validity. An automated voxel selection algorithm was employed to improve MR AIF reproducibility. We found that MR and PET AIFs displayed similar character in the first pass, confirmed by gamma variate fits (p<0.02). MR AIFs displayed reduced PVE compared to PET AIFs, indicating their potential use in PET/MR studies

  8. An Intelligent Automation Platform for Rapid Bioprocess Design

    Science.gov (United States)

    Wu, Tianyi

    2014-01-01

    Bioprocess development is very labor intensive, requiring many experiments to characterize each unit operation in the process sequence to achieve product safety and process efficiency. Recent advances in microscale biochemical engineering have led to automated experimentation. A process design workflow is implemented sequentially in which (1) a liquid-handling system performs high-throughput wet lab experiments, (2) standalone analysis devices detect the data, and (3) specific software is used for data analysis and experiment design given the user’s inputs. We report an intelligent automation platform that integrates these three activities to enhance the efficiency of such a workflow. A multiagent intelligent architecture has been developed incorporating agent communication to perform the tasks automatically. The key contribution of this work is the automation of data analysis and experiment design and also the ability to generate scripts to run the experiments automatically, allowing the elimination of human involvement. A first-generation prototype has been established and demonstrated through lysozyme precipitation process design. All procedures in the case study have been fully automated through an intelligent automation platform. The realization of automated data analysis and experiment design, and automated script programming for experimental procedures has the potential to increase lab productivity. PMID:24088579

  9. Double-radionuclide autoradiographic method using N-isopropyl-iodoamphetamine for sequential measurements of local cerebral blood flow

    International Nuclear Information System (INIS)

    Obrenovitch, T.P.; Clayton, C.B.; Strong, A.J.

    1987-01-01

    A double-radionuclide autoradiographic method has been assessed for sequential determinations of local CBF (LCBF). It is based on two successive intravascular injections of N-isopropyl-p-iodoamphetamine (IMP) labelled with different radionuclides, whose concentrations can later be differentiated in the same tissue section using double-radionuclide autoradiography. Previous studies suggested that the distribution of IMP, up to 30 min after its administration, still represents LCBFs. Our data indicate that, provided the tracer is injected directly into the left ventricle, there is little back diffusion from normal brain to blood under physiological conditions for at least 35 min following the tracer injection and an injection of unlabelled IMP, in a dose larger than that used for blood flow determination, does not displace any labelled IMP previously taken up by the brain, nor does it displace any labelled IMP previously accumulated in the lung that would lead to secondary brain uptake. On the basis of these results, we conclude that sequential autoradiographic determinations of LCBF using IMP labelled with different radionuclides is possible. This is a promising experimental method for the simultaneous investigation of changes in LCBF in several CNS structures

  10. A LabVIEW based template for user created experiment automation.

    Science.gov (United States)

    Kim, D J; Fisk, Z

    2012-12-01

    We have developed an expandable software template to automate user created experiments. The LabVIEW based template is easily modifiable to add together user created measurements, controls, and data logging with virtually any type of laboratory equipment. We use reentrant sequential selection to implement sequence script making it possible to wrap a long series of the user created experiments and execute them in sequence. Details of software structure and application examples for scanning probe microscope and automated transport experiments using custom built laboratory electronics and a cryostat are described.

  11. Iodine speciation in coastal and inland bathing waters and seaweeds extracts using a sequential injection standard addition flow-batch method.

    Science.gov (United States)

    Santos, Inês C; Mesquita, Raquel B R; Bordalo, Adriano A; Rangel, António O S S

    2015-02-01

    The present work describes the development of a sequential injection standard addition method for iodine speciation in bathing waters and seaweeds extracts without prior sample treatment. Iodine speciation was obtained by assessing the iodide and iodate content, the two inorganic forms of iodine in waters. For the determination of iodide, an iodide ion selective electrode (ISE) was used. The indirect determination of iodate was based on the spectrophotometric determination of nitrite (Griess reaction). For the iodate measurement, a mixing chamber was employed (flow batch approach) to explore the inherent efficient mixing, essential for the indirect determination of iodate. The application of the standard addition method enabled detection limits of 0.14 µM for iodide and 0.02 µM for iodate, together with the direct introduction of the target water samples, coastal and inland bathing waters. The results obtained were in agreement with those obtained by ICP-MS and a colorimetric reference procedure. Recovery tests also confirmed the accuracy of the developed method which was effectively applied to bathing waters and seaweed extracts. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Determination of boron in natural water and products derived from grape using an automated flow injection analysis system with piezoelectric detection

    International Nuclear Information System (INIS)

    Jesus, Dosil P. de; Saito, Renata M.; Lago, Claudimir L. do

    2004-01-01

    An automated flow injection analysis system with piezoelectric detection is proposed as a sensitive and selective method for boron. The detector is an electrode-separated piezoelectric quartz crystal coated with N-methyl-D-glucamine-modified poly(epichlorohydrin). The film ability to retain boron allows the adjustment of the linear dynamic range and the sensitivity by varying the injected sample volume. In the present work, the sample volumes were varied from 0.5 to 5.0 mL. Among several ionic species, germanate is the only one that can interfere in the method. Nevertheless, it can be eliminated by addition of sulfide to the sample. The method was successfully applied to the determination of boron concentration in samples of natural water (from 1.71 to 309 μL -1 ) and products derived from grape juice (from 2.06 to 6.21 mg L -1 ). A pretreatment with hydrogen peroxide in alkaline medium was required due to the great amount of sugars in the grape products (author)

  13. Toxicity assessment of ionic liquids with Vibrio fischeri: an alternative fully automated methodology.

    Science.gov (United States)

    Costa, Susana P F; Pinto, Paula C A G; Lapa, Rui A S; Saraiva, M Lúcia M F S

    2015-03-02

    A fully automated Vibrio fischeri methodology based on sequential injection analysis (SIA) has been developed. The methodology was based on the aspiration of 75 μL of bacteria and 50 μL of inhibitor followed by measurement of the luminescence of bacteria. The assays were conducted for contact times of 5, 15, and 30 min, by means of three mixing chambers that ensured adequate mixing conditions. The optimized methodology provided a precise control of the reaction conditions which is an asset for the analysis of a large number of samples. The developed methodology was applied to the evaluation of the impact of a set of ionic liquids (ILs) on V. fischeri and the results were compared with those provided by a conventional assay kit (Biotox(®)). The collected data evidenced the influence of different cation head groups and anion moieties on the toxicity of ILs. Generally, aromatic cations and fluorine-containing anions displayed higher impact on V. fischeri, evidenced by lower EC50. The proposed methodology was validated through statistical analysis which demonstrated a strong positive correlation (P>0.98) between assays. It is expected that the automated methodology can be tested for more classes of compounds and used as alternative to microplate based V. fischeri assay kits. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Comparison of first pass bolus AIFs extracted from sequential {sup 18}F-FDG PET and DSC-MRI of mice

    Energy Technology Data Exchange (ETDEWEB)

    Evans, Eleanor, E-mail: ee244@cam.ac.uk [Wolfson Brain Imaging Centre, Department of Clinical Neurosciences, School of Clinical Medicine, University of Cambridge, Cambridge Biomedical Campus, Cambridge, CB2 0QQ (United Kingdom); Sawiak, Stephen J. [Wolfson Brain Imaging Centre, Department of Clinical Neurosciences, School of Clinical Medicine, University of Cambridge, Cambridge Biomedical Campus, Cambridge, CB2 0QQ (United Kingdom); Behavioural and Clinical Neuroscience Institute, Department of Experimental Psychology, University of Cambridge, Cambridge, CB2 3EB (United Kingdom); Ward, Alexander O.; Buonincontri, Guido; Hawkes, Robert C.; Adrian Carpenter, T. [Wolfson Brain Imaging Centre, Department of Clinical Neurosciences, School of Clinical Medicine, University of Cambridge, Cambridge Biomedical Campus, Cambridge, CB2 0QQ (United Kingdom)

    2014-01-11

    Accurate kinetic modelling of in vivo physiological function using positron emission tomography (PET) requires determination of the tracer time–activity curve in plasma, known as the arterial input function (AIF). The AIF is usually determined by invasive blood sampling methods, which are prohibitive in murine studies due to low total blood volumes. Extracting AIFs from PET images is also challenging due to large partial volume effects (PVE). We hypothesise that in combined PET with magnetic resonance imaging (PET/MR), a co-injected bolus of MR contrast agent and PET ligand can be tracked using fast MR acquisitions. This protocol would allow extraction of a MR AIF from MR contrast agent concentration–time curves, at higher spatial and temporal resolution than an image-derived PET AIF. A conversion factor could then be applied to the MR AIF for use in PET kinetic analysis. This work has compared AIFs obtained from sequential DSC-MRI and PET with separate injections of gadolinium contrast agent and {sup 18}F-FDG respectively to ascertain the technique′s validity. An automated voxel selection algorithm was employed to improve MR AIF reproducibility. We found that MR and PET AIFs displayed similar character in the first pass, confirmed by gamma variate fits (p<0.02). MR AIFs displayed reduced PVE compared to PET AIFs, indicating their potential use in PET/MR studies.

  15. Fabrication of miniaturized electrostatic deflectors using LIGA

    International Nuclear Information System (INIS)

    Jackson, K.H.; Khan-Malek, C.; Muray, L.P.

    1997-01-01

    Miniaturized electron beam columns (open-quotes microcolumnsclose quotes) have been demonstrated to be suitable candidates for scanning electron microscopy (SEM), e-beam lithography and other high resolution, low voltage applications. In the present technology, microcolumns consist of open-quotes selectively scaledclose quotes micro-sized lenses and apertures, fabricated from silicon membranes with e-beam lithography, reactive ion beam etching and other semiconductor thin-film techniques. These miniaturized electron-optical elements provide significant advantages over conventional optics in performance and ease of fabrication. Since lens aberrations scale roughly with size, it is possible to fabricate simple microcolumns with extremely high brightness sources and electrostatic objective lenses, with resolution and beam current comparable to conventional e-beam columns. Moreover since microcolumns typically operate at low voltages (1 KeV), the proximity effects encountered in e-beam lithography become negligible. For high throughput applications, batch fabrication methods may be used to build large parallel arrays of microcolumns. To date, the best reported performance with a 1 keV cold field emission cathode, is 30 nm resolution at a working distance of 2mm in a 3.5mm column. Fabrication of the microcolumn deflector and stigmator, however, have remained beyond the capabilities of conventional machining operations and semiconductor processing technology. This work examines the LIGA process as a superior alternative to fabrication of the deflectors, especially in terms of degree of miniaturization, dimensional control, placement accuracy, run-out, facet smoothness and choice of suitable materials. LIGA is a combination of deep X-ray lithography, electroplating, and injection molding processes which allow the fabrication of microstructures

  16. A análise por injeção sequencial (SIA: vinte anos em uma perspectiva brasileira

    Directory of Open Access Journals (Sweden)

    Allan Cezar Vieira dos Santos

    2010-01-01

    Full Text Available The year of 2010 marks the 20th anniversary of the development of Sequential Injection Analysis (SIA by Ruzicka and Marshall. Considered the second generation of the flow injection methods, this article briefly describes the history, the basic principles of the technique and reviews all papers developed by Brazilian scientists aiming the divulgation of this automation technique in Analytical Chemistry.

  17. Automated electronic tongue based on potentiometric sensors for the determination of a trinary anionic surfactant mixture.

    Science.gov (United States)

    Cortina, Montserrat; Ecker, Christina; Calvo, Daniel; del Valle, Manuel

    2008-01-22

    An automated electronic tongue consisting of an array of potentiometric sensors and an artificial neural network (ANN) has been developed to resolve mixtures of anionic surfactants. The sensor array was formed by five different flow-through sensors for anionic surfactants, based on poly(vinyl chloride) membranes having cross-sensitivity features. Feedforward multilayer neural networks were used to predict surfactant concentrations. As a great amount of information is required for the correct modelling of the sensors response, a sequential injection analysis (SIA) system was used to automatically provide it. Dodecylsulfate (DS(-)), dodecylbenzenesulfonate (DBS(-)) and alpha-alkene sulfonate (ALF(-)) formed the three-analyte study case resolved in this work. Their concentrations varied from 0.2 to 4mM for ALF(-) and DBS(-) and from 0.2 to 5mM for DS(-). Good prediction ability was obtained with correlation coefficients better than 0.933 when the obtained values were compared with those expected for a set of 16 external test samples not used for training.

  18. Quantum dots as chemiluminescence enhancers tested by sequential injection technique: Comparison of flow and flow-batch conditions

    Energy Technology Data Exchange (ETDEWEB)

    Sklenářová, Hana, E-mail: sklenarova@faf.cuni.cz [Charles University in Prague, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Hradec Králové (Czech Republic); Voráčová, Ivona [Institute of Analytical Chemistry of the CAS, v. v. i., Brno (Czech Republic); Chocholouš, Petr; Polášek, Miroslav [Charles University in Prague, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Hradec Králové (Czech Republic)

    2017-04-15

    The effect of 0.01–100 µmol L{sup −1} Quantum Dots (QDs) with different emission wavelengths (520–640 nm) and different surface modifications (mercaptopropionic, mercaptoundecanoic, thioglycolic acids and mercaptoethylamine) on permanganate-induced and luminol–hydrogen peroxide chemiluminescence (CL) was studied in detail by a sequential injection technique using a spiral detection flow cell and a flow-batch detection cell operated in flow and stop-flow modes. In permanganate CL system no significant enhancement of the CL signal was observed while for the luminol–hydrogen peroxide CL substantial increase (>100% and >90% with the spiral detection cell in flow and stop-flow modes, respectively) was attained for CdTe QDs. Enhancement exceeding 120% was observed for QDs with emissions at 520, 575 and 603 nm (sizes of 2.8 nm, 3.3 nm and 3.6 nm) using the flow-batch detection cell in the stop-flow mode. Pronounced effect was noted for surface modifications while mercaptoethylamine was the most efficient in CL enhancement compared to mercaptopropionic acid the most commonly applied coating. Significant difference between results obtained in flow and flow-batch conditions based on the entire kinetics of the extremely fast CL reaction was discussed. The increase of the CL signal was always accompanied by reduced lifetime of the CL emission thus application of QDs in flow techniques should be always coupled with the study of the CL lifetime.

  19. Electrogenerated chemiluminescence induced by sequential hot electron and hole injection into aqueous electrolyte solution

    Energy Technology Data Exchange (ETDEWEB)

    Salminen, Kalle; Kuosmanen, Päivi; Pusa, Matti [Aalto University, Department of Chemistry, Laboratory of Analytical Chemistry, P.O. Box 16100, FI-00076 Aalto (Finland); Kulmala, Oskari [University of Helsinki, Department of Physics, P.O. Box 64, FI-00014 (Finland); Håkansson, Markus [Aalto University, Department of Chemistry, Laboratory of Analytical Chemistry, P.O. Box 16100, FI-00076 Aalto (Finland); Kulmala, Sakari, E-mail: sakari.kulmala@aalto.fi [Aalto University, Department of Chemistry, Laboratory of Analytical Chemistry, P.O. Box 16100, FI-00076 Aalto (Finland)

    2016-03-17

    Hole injection into aqueous electrolyte solution is proposed to occur when oxide-coated aluminum electrode is anodically pulse-polarized by a voltage pulse train containing sufficiently high-voltage anodic pulses. The effects of anodic pulses are studied by using an aromatic Tb(III) chelate as a probe known to produce intensive hot electron-induced electrochemiluminescence (HECL) with plain cathodic pulses and preoxidized electrodes. The presently studied system allows injection of hot electrons and holes successively into aqueous electrolyte solutions and can be utilized in detecting electrochemiluminescent labels in fully aqueous solutions, and actually, the system is suggested to be quite close to a pulse radiolysis system providing hydrated electrons and hydroxyl radicals as the primary radicals in aqueous solution without the problems and hazards of ionizing radiation. The analytical power of the present excitation waveforms are that they allow detection of electrochemiluminescent labels at very low detection limits in bioaffinity assays such as in immunoassays or DNA probe assays. The two important properties of the present waveforms are: (i) they provide in situ oxidation of the electrode surface resulting in the desired oxide film thickness and (ii) they can provide one-electron oxidants for the system by hole injection either via F- and F{sup +}-center band of the oxide or by direct hole injection to valence band of water at highly anodic pulse amplitudes. - Highlights: • Hot electrons injected into aqueous electrolyte solution. • Generation of hydrated electrons. • Hole injection into aqueous electrolyte solution. • Generation of hydroxyl radicals.

  20. The Impact of Flow Injection on Modern Chemical Analysis

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    and preconcentration procedures. In recent years, FIA has been supplemented by Sequential Injection Analysis (SIA) and the Lab-on-Valve (LOV) approach. Following a brief historic introduction and an account of the impact of FIA in academia, the lecture will describe these two new generations of FIA, accompanied...

  1. Automated Attitude Sensor Calibration: Progress and Plans

    Science.gov (United States)

    Sedlak, Joseph; Hashmall, Joseph

    2004-01-01

    This paper describes ongoing work a NASA/Goddard Space Flight Center to improve the quality of spacecraft attitude sensor calibration and reduce costs by automating parts of the calibration process. The new calibration software can autonomously preview data quality over a given time span, select a subset of the data for processing, perform the requested calibration, and output a report. This level of automation is currently being implemented for two specific applications: inertial reference unit (IRU) calibration and sensor alignment calibration. The IRU calibration utility makes use of a sequential version of the Davenport algorithm. This utility has been successfully tested with simulated and actual flight data. The alignment calibration is still in the early testing stage. Both utilities will be incorporated into the institutional attitude ground support system.

  2. A Customizable Flow Injection System for Automated, High Throughput, and Time Sensitive Ion Mobility Spectrometry and Mass Spectrometry Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Orton, Daniel J. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Tfaily, Malak M. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Moore, Ronald J. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; LaMarche, Brian L. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Zheng, Xueyun [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Fillmore, Thomas L. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Chu, Rosalie K. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Weitz, Karl K. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Monroe, Matthew E. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Kelly, Ryan T. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Smith, Richard D. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Baker, Erin S. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States

    2017-12-13

    To better understand disease conditions and environmental perturbations, multi-omic studies (i.e. proteomic, lipidomic, metabolomic, etc. analyses) are vastly increasing in popularity. In a multi-omic study, a single sample is typically extracted in multiple ways and numerous analyses are performed using different instruments. Thus, one sample becomes many analyses, making high throughput and reproducible evaluations a necessity. One way to address the numerous samples and varying instrumental conditions is to utilize a flow injection analysis (FIA) system for rapid sample injection. While some FIA systems have been created to address these challenges, many have limitations such as high consumable costs, low pressure capabilities, limited pressure monitoring and fixed flow rates. To address these limitations, we created an automated, customizable FIA system capable of operating at diverse flow rates (~50 nL/min to 500 µL/min) to accommodate low- and high-flow instrument sources. This system can also operate at varying analytical throughputs from 24 to 1200 samples per day to enable different MS analysis approaches. Applications ranging from native protein analyses to molecular library construction were performed using the FIA system. The results from these studies showed a highly robust platform, providing consistent performance over many days without carryover as long as washing buffers specific to each molecular analysis were utilized.

  3. Microcolumn-based speciation analysis of thallium in soil and green cabbage.

    Science.gov (United States)

    Jia, Yanlong; Xiao, Tangfu; Sun, Jialong; Yang, Fei; Baveye, Philippe C

    2018-07-15

    Thallium (Tl) is a toxic trace metal, whose geochemical behavior and biological effects are closely controlled by its chemical speciation in the environment. However, little tends to be known about this speciation of Tl in soil and plant systems that directly affect the safety of food supplies. In this context, the objective of the present study was to elaborate an efficient method to separate and detect Tl(I) and Tl(III) species for soil and plant samples. This method involves the selective adsorption of Tl(I) on microcolumns filled with immobilized oxine, in the presence of DTPA (diethylenetriaminepentaacetic acid), followed by DTPA-enhanced ultrasonic and heating-induced extraction, coupled with ICP-MS detection. The method was characterized by a LOD of 0.037 μg/L for Tl(I) and 0.18 μg/L for Tl(III) in 10  mL samples. With this method, a second objective of the research was to assess the speciation of Tl in pot and field soils and in green cabbage crops. Experimental results suggest that DTPA extracted Tl was mainly present as Tl(I) in soils (>95%). Tl in hyperaccumulator plant green cabbage was also mainly present as Tl(I) (>90%). With respect to Tl uptake in plants, this study provides direct evidence that green cabbage mainly takes up Tl(I) from soil, and transports it into the aboveground organs. In soils, Tl(III) is reduced to Tl(I) even at the surface where the chemical environment promotes oxidation. This observation is conducive to understanding the mechanisms of Tl isotope fractionation in the soil-plant system. Based on geochemical fraction studies, the reducible fraction was the main source of Tl getting accumulated by plants. These results indicate that the improved analytical method presented in this study offers an economical, simple, fast, and sensitive approach for the separation of Tl species present in soils at trace levels. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Fully automated data collection and processing system on macromolecular crystallography beamlines at the PF

    International Nuclear Information System (INIS)

    Yamada, Yusuke; Hiraki, Masahiko; Matsugaki, Naohiro; Chavas, Leonard M.G.; Igarashi, Noriyuki; Wakatsuki, Soichi

    2012-01-01

    Fully automated data collection and processing system has been developed on macromolecular crystallography beamlines at the Photon Factory. In this system, the sample exchange, centering and data collection are sequentially performed for all samples stored in the sample exchange system at a beamline without any manual operations. Data processing of collected data sets is also performed automatically. These results are stored into the database system, and users can monitor the progress and results of automated experiment via a Web browser. (author)

  5. Assessment of cellular viability on calcium sulphate/hydroxyapatite injectable scaffolds

    Directory of Open Access Journals (Sweden)

    Randa Alfotawi

    2013-10-01

    Full Text Available Cements for maxillofacial reconstruction of jaw defects through calcification of rotated muscle have been tested. The objective of this study was to investigate the visibility of loading of two types of commercially available cements, Cerament™ Spine Support and Cerament Bone Void Filler with mesenchymal cells and cytokines (bone morphogenetic protein to act as a biomimetic scaffolding for future clinical application. Determination of basic biocompatibility (cell viability using methyl thiazolyl tetrazolium and live/dead assay was carried out using MG-63 cells at various time points. Next, in order to inform potential subsequent in vivo experiments, a collagen tissue mimic was used for characterization of rabbit mesenchymal stromal cells using immunofluorescent cytoskeleton staining, and simultaneous and then sequential injection of Cerament Spine Support cement and cells into collagen gels. Results indicated that Cerament Spine Support was more biocompatible and that sequential injection of cement and then rabbit mesenchymal stromal cells into the tissue mimics is an optimal approach for clinical applications.

  6. Energetic electron injections and dipolarization events in Mercury's magnetotail: Substorm dynamics

    Science.gov (United States)

    Dewey, R. M.; Slavin, J. A.; Raines, J. M.; Imber, S.; Baker, D. N.; Lawrence, D. J.

    2017-12-01

    Despite its small size, Mercury's terrestrial-like magnetosphere experiences brief, yet intense, substorm intervals characterized by features similar to at Earth: loading/unloading of the tail lobes with open magnetic flux, dipolarization of the magnetic field at the inner edge of the plasma sheet, and, the focus of this presentation, energetic electron injection. We use the Gamma-Ray Spectrometer's high-time resolution (10 ms) energetic electron measurements to determine the relationship between substorm activity and energetic electron injections coincident with dipolarization fronts in the magnetotail. These dipolarizations were detected on the basis of their rapid ( 2 s) increase in the northward component of the tail magnetic field (ΔBz 30 nT), which typically persists for 10 s. We estimate the typical flow channel to be 0.15 RM, planetary convection speed of 750 km/s, cross-tail potential drop of 7 kV, and flux transport of 0.08 MWb for each dipolarization event, suggesting multiple simultaneous and sequential dipolarizations are required to unload the >1 MWb of magnetic flux typically returned to the dayside magnetosphere during a substorm interval. Indeed, while we observe most dipolarization-injections to be isolated or in small chains of events (i.e., 1-3 events), intervals of sawtooth-like injections with >20 sequential events are also present. The typical separation between dipolarization-injection events is 10 s. Magnetotail dipolarization, in addition to being a powerful source of electron acceleration, also plays a significant role in the substorm process at Mercury.

  7. Studies in Fat Grafting: Part II. Effects of Injection Mechanics on Material Properties of Fat

    Science.gov (United States)

    Atashroo, David; Raphel, Jordan; Chung, Michael T.; Paik, Kevin J.; Parisi-Amon, Andreina; McArdle, Adrian; Senarath-Yapa, Kshemendra; Zielins, Elizabeth R.; Tevlin, Ruth; Duldulao, Chris; Walmsley, Graham G.; Hu, Michael S.; Momeni, Arash; Domecus, Brian; Rimsa, Joe R.; Greenberg, Lauren; Gurtner, Geoffrey C.; Longaker, Michael T.; Wan, Derrick C.

    2014-01-01

    Background While fat grafting can address many soft tissue deficits, results remain inconsistent. In this study, we compared physical properties of fat following injection using an automated, low shear device or the modified Coleman technique. Methods Lipoaspirate was obtained from nine patients and processed for injection using either a modified Coleman technique or with an automated, low shear device. Fat was passed through a 2 mm cannula and compared to minimally processed fat. A rheometer was used to measure the storage modulus and shear rate at which tissues began to lose their solid-like properties. Viscosity was also measured and gross properties of treatment groups were qualitatively evaluated with a glass slide test. Results Fat injected through an automated, low shear device closely matched physical properties of minimally processed fat. The storage modulus (G′) of fat for the device group was greater than the modified Coleman group and the onset of breakdown was delayed. Similarly, viscosity measurement of fat from the automated device closely matched minimally processed fat and was greater than the modified Coleman group. Conclusions The physical properties of lipoaspirate processed using an automated, low shear device with a 2 mm cannula preserved the intactness of fat more than the modified Coleman technique. Our rheological data demonstrate less damage using an automated device compared to modified Coleman technique and potentially support its use for improved fat graft integrity. PMID:25028817

  8. Development of the computer-aided process planning (CAPP system for polymer injection molds manufacturing

    Directory of Open Access Journals (Sweden)

    J. Tepić

    2011-10-01

    Full Text Available Beginning of production and selling of polymer products largely depends on mold manufacturing. The costs of mold manufacturing have significant share in the final price of a product. The best way to improve and rationalize polymer injection molds production process is by doing mold design automation and manufacturing process planning automation. This paper reviews development of a dedicated process planning system for manufacturing of the mold for injection molding, which integrates computer-aided design (CAD, computer-aided process planning (CAPP and computer-aided manufacturing (CAM technologies.

  9. A Customizable Flow Injection System for Automated, High Throughput, and Time Sensitive Ion Mobility Spectrometry and Mass Spectrometry Measurements.

    Science.gov (United States)

    Orton, Daniel J; Tfaily, Malak M; Moore, Ronald J; LaMarche, Brian L; Zheng, Xueyun; Fillmore, Thomas L; Chu, Rosalie K; Weitz, Karl K; Monroe, Matthew E; Kelly, Ryan T; Smith, Richard D; Baker, Erin S

    2018-01-02

    To better understand disease conditions and environmental perturbations, multiomic studies combining proteomic, lipidomic, and metabolomic analyses are vastly increasing in popularity. In a multiomic study, a single sample is typically extracted in multiple ways, and various analyses are performed using different instruments, most often based upon mass spectrometry (MS). Thus, one sample becomes many measurements, making high throughput and reproducible evaluations a necessity. One way to address the numerous samples and varying instrumental conditions is to utilize a flow injection analysis (FIA) system for rapid sample injections. While some FIA systems have been created to address these challenges, many have limitations such as costly consumables, low pressure capabilities, limited pressure monitoring, and fixed flow rates. To address these limitations, we created an automated, customizable FIA system capable of operating at a range of flow rates (∼50 nL/min to 500 μL/min) to accommodate both low- and high-flow MS ionization sources. This system also functions at varying analytical throughputs from 24 to 1200 samples per day to enable different MS analysis approaches. Applications ranging from native protein analyses to molecular library construction were performed using the FIA system, and results showed a highly robust and reproducible platform capable of providing consistent performance over many days without carryover, as long as washing buffers specific to each molecular analysis were utilized.

  10. Automated thermochemolysis reactor for detection of Bacillus anthracis endospores by gas chromatography–mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Li, Dan [Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602 (United States); Rands, Anthony D.; Losee, Scott C. [Torion Technologies, American Fork, UT 84003 (United States); Holt, Brian C. [Department of Statistics, Brigham Young University, Provo, UT 84602 (United States); Williams, John R. [Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602 (United States); Lammert, Stephen A. [Torion Technologies, American Fork, UT 84003 (United States); Robison, Richard A. [Department of Microbiology and Molecular Biology, Brigham Young University, Provo, UT 84602 (United States); Tolley, H. Dennis [Department of Statistics, Brigham Young University, Provo, UT 84602 (United States); Lee, Milton L., E-mail: milton_lee@byu.edu [Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602 (United States)

    2013-05-02

    Graphical abstract: -- Highlights: •An automated sample preparation system for Bacillus anthracis endospores was developed. •A thermochemolysis method was applied to produce and derivatize biomarkers for Bacillus anthracis detection. •The autoreactor controlled the precise delivery of reagents, and TCM reaction times and temperatures. •Solid phase microextraction was used to extract biomarkers, and GC–MS was used for final identification. •This autoreactor was successfully applied to the identification of Bacillus anthracis endospores. -- Abstract: An automated sample preparation system was developed and tested for the rapid detection of Bacillus anthracis endospores by gas chromatography–mass spectrometry (GC–MS) for eventual use in the field. This reactor is capable of automatically processing suspected bio-threat agents to release and derivatize unique chemical biomarkers by thermochemolysis (TCM). The system automatically controls the movement of sample vials from one position to another, crimping of septum caps onto the vials, precise delivery of reagents, and TCM reaction times and temperatures. The specific operations of introduction of sample vials, solid phase microextraction (SPME) sampling, injection into the GC–MS system, and ejection of used vials from the system were performed manually in this study, although they can be integrated into the automated system. Manual SPME sampling is performed by following visual and audible signal prompts for inserting the fiber into and retracting it from the sampling port. A rotating carousel design allows for simultaneous sample collection, reaction, biomarker extraction and analysis of sequential samples. Dipicolinic acid methyl ester (DPAME), 3-methyl-2-butenoic acid methyl ester (a fragment of anthrose) and two methylated sugars were used to compare the performance of the autoreactor with manual TCM. Statistical algorithms were used to construct reliable bacterial endospore signatures, and 24

  11. Automated thermochemolysis reactor for detection of Bacillus anthracis endospores by gas chromatography–mass spectrometry

    International Nuclear Information System (INIS)

    Li, Dan; Rands, Anthony D.; Losee, Scott C.; Holt, Brian C.; Williams, John R.; Lammert, Stephen A.; Robison, Richard A.; Tolley, H. Dennis; Lee, Milton L.

    2013-01-01

    Graphical abstract: -- Highlights: •An automated sample preparation system for Bacillus anthracis endospores was developed. •A thermochemolysis method was applied to produce and derivatize biomarkers for Bacillus anthracis detection. •The autoreactor controlled the precise delivery of reagents, and TCM reaction times and temperatures. •Solid phase microextraction was used to extract biomarkers, and GC–MS was used for final identification. •This autoreactor was successfully applied to the identification of Bacillus anthracis endospores. -- Abstract: An automated sample preparation system was developed and tested for the rapid detection of Bacillus anthracis endospores by gas chromatography–mass spectrometry (GC–MS) for eventual use in the field. This reactor is capable of automatically processing suspected bio-threat agents to release and derivatize unique chemical biomarkers by thermochemolysis (TCM). The system automatically controls the movement of sample vials from one position to another, crimping of septum caps onto the vials, precise delivery of reagents, and TCM reaction times and temperatures. The specific operations of introduction of sample vials, solid phase microextraction (SPME) sampling, injection into the GC–MS system, and ejection of used vials from the system were performed manually in this study, although they can be integrated into the automated system. Manual SPME sampling is performed by following visual and audible signal prompts for inserting the fiber into and retracting it from the sampling port. A rotating carousel design allows for simultaneous sample collection, reaction, biomarker extraction and analysis of sequential samples. Dipicolinic acid methyl ester (DPAME), 3-methyl-2-butenoic acid methyl ester (a fragment of anthrose) and two methylated sugars were used to compare the performance of the autoreactor with manual TCM. Statistical algorithms were used to construct reliable bacterial endospore signatures, and 24

  12. How Flow Injection Analysis (FIA) over the past 25 years has changed our way of performing chemical analyses

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Miró, Manuel

    2007-01-01

    Briefly looking back on the impact of flow injection analysis (FIA), as reflected in the rapid growth of publications in the scientific literature, and touching upon many of the novel and unique analytical chemical possibilities that FIA and its sequels, sequential injection analysis (SIA) and La...

  13. Sequential Power-Dependence Theory

    NARCIS (Netherlands)

    Buskens, Vincent; Rijt, Arnout van de

    2008-01-01

    Existing methods for predicting resource divisions in laboratory exchange networks do not take into account the sequential nature of the experimental setting. We extend network exchange theory by considering sequential exchange. We prove that Sequential Power-Dependence Theory—unlike

  14. ANALYSIS OF DRUG-PROTEIN BINDING BY ULTRAFAST AFFINITY CHROMATOGRAPHY USING IMMOBILIZED HUMAN SERUM ALBUMIN

    Science.gov (United States)

    Mallik, Rangan; Yoo, Michelle J.; Briscoe, Chad J.; Hage, David S.

    2010-01-01

    Human serum albumin (HSA) was explored for use as a stationary phase and ligand in affinity microcolumns for the ultrafast extraction of free drug fractions and the use of this information for the analysis of drug-protein binding. Warfarin, imipramine, and ibuprofen were used as model analytes in this study. It was found that greater than 95% extraction of all these drugs could be achieved in as little as 250 ms on HSA microcolumns. The retained drug fraction was then eluted from the same column under isocratic conditions, giving elution in less than 40 s when working at 4.5 mL/min. The chromatographic behavior of this system gave a good fit with that predicted by computer simulations based on a reversible, saturable model for the binding of an injected drug with immobilized HSA. The free fractions measured by this method were found to be comparable to those determined by ultrafiltration, and equilibrium constants estimated by this approach gave good agreement with literature values. Advantages of this method include its speed and the relatively low cost of microcolumns that contain HSA. The ability of HSA to bind many types of drugs also creates the possibility of using the same affinity microcolumn to study and measure the free fractions for a variety of pharmaceutical agents. These properties make this technique appealing for use in drug binding studies and in the high-throughput screening of new drug candidates. PMID:20227701

  15. Automated ultrasonic inspection system for nuclear power stations

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    The automated system of ultrasonic inspection which was used to conduct weld inspections of the complex primary system of the Borselle PWR station is described. It relies upon mechanically traversing purpose designed multi-crystal ultrasonic probes along the welds. A number of probes are switched sequentially to provide a continuous scan. A typical scan rate of 120 scan/sec is achieved by a multiplexer capable of switching transmitter and receiver individually. The system has wide applications in other industries. (U.K.)

  16. Bioremediation of PAHs contaminated river sediment by an integrated approach with sequential injection of co-substrate and electron acceptor: Lab-scale study.

    Science.gov (United States)

    Liu, Tongzhou; Zhang, Zhen; Dong, Wenyi; Wu, Xiaojing; Wang, Hongjie

    2017-11-01

    In this study, the feasibility of employing an integrated bioremediation approach in contaminated river sediment was evaluated. Sequential addition of co-substrate (acetate) and electron acceptor (NO 3 - ) in a two-phase treatment was capable of effectively removing polycyclic aromatic hydrocarbons (PAHs) in river sediment. The residual concentration of total PAHs decreased to far below effect range low (ERL) value within 91 days of incubation, at which concentration it could rarely pose biological impairment. The biodegradation of high molecular weight PAHs were found to be mainly occurred in the sediment treated with co-substrates (i.e. acetate or methanol), in which acetate was found to be more suitable for PAHs degradation. The role of co-substrates in influencing PAHs biodegradation was tentatively discussed herein. Additionally, the sediment odorous problem and blackish appearance were intensively addressed by NO 3 - injection. The results of this study demonstrated that integrating two or more approaches/processes would be a helpful option in sediment remediation. It can lead to a more effective remediation performance, handle multiple contamination issues, as well as mitigate environmental risks caused by one of the single methods. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Automated dual capillary electrophoresis system with hydrodynamic injection for the concurrent determination of cations and anions

    Energy Technology Data Exchange (ETDEWEB)

    Pham, Thi Thanh Thuy; Mai, Thanh Duc [University of Basel, Department of Chemistry, Spitalstrasse 51, Basel 4056 (Switzerland); Centre for Environmental Technology and Sustainable Development (CETASD), Hanoi University of Science, Nguyen Trai Street 334, Hanoi (Viet Nam); Nguyen, Thanh Dam [Centre for Environmental Technology and Sustainable Development (CETASD), Hanoi University of Science, Nguyen Trai Street 334, Hanoi (Viet Nam); Sáiz, Jorge [Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering – University of Alcalá, Ctra. Madrid-Barcelona km 33.6, Alcalá de Henares, Madrid 28871 (Spain); Pham, Hung Viet, E-mail: phamhungviet@hus.edu.vn [Centre for Environmental Technology and Sustainable Development (CETASD), Hanoi University of Science, Nguyen Trai Street 334, Hanoi (Viet Nam); Hauser, Peter C., E-mail: Peter.Hauser@unibas.ch [University of Basel, Department of Chemistry, Spitalstrasse 51, Basel 4056 (Switzerland)

    2014-09-02

    Highlights: • Concurrent determination of cations and anions was carried out by electrophoretic separation. • Optimized conditions for each class of analystes was possible by using separate capillaries. • Simultaneous hydrodynamic injection was carried out. • Pneumatic actuation was used for flushing and sample handling. • The denitrification of drinking water was successfully demonstrated. - Abstract: The capillary electrophoresis instrument developed for the concurrent determination of cations and anions features two separate capillaries and individual detectors to allow independent optimization for each group of ions. The capillaries are joined in a common injector block. The sample is drawn into the injector with a small membrane pump and automated simultaneous injection into both capillaries is achieved by pressurization of the fluid with compressed air. Flushing of the injector and of the capillaries with the background electrolyte is also carried out automatically by the same means. The buffer consisted of 12 mM histidine and 2 mM 18-crown-6 adjusted to pH 4 with acetic acid and was suitable for the contactless conductivity detection employed. The system was optimized for the determination of cationic NH{sub 4}{sup +} and anionic NO{sub 3}{sup −} and NO{sub 2}{sup −}, and linear calibration curves from about 20 μM up to about 1.5 mM were obtained for these ions. In a test run over 8 h, the reproducibility for the peak areas was within ±7%. For demonstration, the instrument was successfully applied to the concurrent monitoring of the concentrations of the three ions during the biological removal of ammonium from contaminated groundwater in a sequencing batch reactor, where NO{sub 3}{sup −} and NO{sub 2}{sup −} are formed as intermediate products.

  18. Method for semi-automated microscopy of filtration-enriched circulating tumor cells.

    Science.gov (United States)

    Pailler, Emma; Oulhen, Marianne; Billiot, Fanny; Galland, Alexandre; Auger, Nathalie; Faugeroux, Vincent; Laplace-Builhé, Corinne; Besse, Benjamin; Loriot, Yohann; Ngo-Camus, Maud; Hemanda, Merouan; Lindsay, Colin R; Soria, Jean-Charles; Vielh, Philippe; Farace, Françoise

    2016-07-14

    Circulating tumor cell (CTC)-filtration methods capture high numbers of CTCs in non-small-cell lung cancer (NSCLC) and metastatic prostate cancer (mPCa) patients, and hold promise as a non-invasive technique for treatment selection and disease monitoring. However filters have drawbacks that make the automation of microscopy challenging. We report the semi-automated microscopy method we developed to analyze filtration-enriched CTCs from NSCLC and mPCa patients. Spiked cell lines in normal blood and CTCs were enriched by ISET (isolation by size of epithelial tumor cells). Fluorescent staining was carried out using epithelial (pan-cytokeratins, EpCAM), mesenchymal (vimentin, N-cadherin), leukocyte (CD45) markers and DAPI. Cytomorphological staining was carried out with Mayer-Hemalun or Diff-Quik. ALK-, ROS1-, ERG-rearrangement were detected by filter-adapted-FISH (FA-FISH). Microscopy was carried out using an Ariol scanner. Two combined assays were developed. The first assay sequentially combined four-color fluorescent staining, scanning, automated selection of CD45(-) cells, cytomorphological staining, then scanning and analysis of CD45(-) cell phenotypical and cytomorphological characteristics. CD45(-) cell selection was based on DAPI and CD45 intensity, and a nuclear area >55 μm(2). The second assay sequentially combined fluorescent staining, automated selection of CD45(-) cells, FISH scanning on CD45(-) cells, then analysis of CD45(-) cell FISH signals. Specific scanning parameters were developed to deal with the uneven surface of filters and CTC characteristics. Thirty z-stacks spaced 0.6 μm apart were defined as the optimal setting, scanning 82 %, 91 %, and 95 % of CTCs in ALK-, ROS1-, and ERG-rearranged patients respectively. A multi-exposure protocol consisting of three separate exposure times for green and red fluorochromes was optimized to analyze the intensity, size and thickness of FISH signals. The semi-automated microscopy method reported here

  19. The Origin of Sequential Chromospheric Brightenings

    Science.gov (United States)

    Kirk, M. S.; Balasubramaniam, K. S.; Jackiewicz, J.; Gilbert, H. R.

    2017-06-01

    Sequential chromospheric brightenings (SCBs) are often observed in the immediate vicinity of erupting flares and are associated with coronal mass ejections. Since their initial discovery in 2005, there have been several subsequent investigations of SCBs. These studies have used differing detection and analysis techniques, making it difficult to compare results between studies. This work employs the automated detection algorithm of Kirk et al. (Solar Phys. 283, 97, 2013) to extract the physical characteristics of SCBs in 11 flares of varying size and intensity. We demonstrate that the magnetic substructure within the SCB appears to have a significantly smaller area than the corresponding Hα emission. We conclude that SCBs originate in the lower corona around 0.1 R_{⊙} above the photosphere, propagate away from the flare center at speeds of 35 - 85 km s^{-1}, and have peak photosphere magnetic intensities of 148±2.9 G. In light of these measurements, we infer SCBs to be distinctive chromospheric signatures of erupting coronal mass ejections.

  20. Development of integrated control system for smart factory in the injection molding process

    Science.gov (United States)

    Chung, M. J.; Kim, C. Y.

    2018-03-01

    In this study, we proposed integrated control system for automation of injection molding process required for construction of smart factory. The injection molding process consists of heating, tool close, injection, cooling, tool open, and take-out. Take-out robot controller, image processing module, and process data acquisition interface module are developed and assembled to integrated control system. By adoption of integrated control system, the injection molding process can be simplified and the cost for construction of smart factory can be inexpensive.

  1. Improved detection of hydrophilic phosphopeptides using graphite powder microcolumns and mass spectrometry: evidence for in vivo doubly phosphorylated dynamin I and dynamin III

    DEFF Research Database (Denmark)

    Larsen, Martin Røssel; Graham, Mark E; Robinson, Phillip J

    2004-01-01

    A common strategy in proteomics to improve the number and quality of peptides detected by mass spectrometry (MS) is to desalt and concentrate proteolytic digests using reversed phase (RP) chromatography prior to analysis. However, this does not allow for detection of small or hydrophilic peptides...... a large improvement in the detection of small amounts of phosphopeptides by MS and the approach has major implications for both small- and large-scale projects in phosphoproteomics.......A common strategy in proteomics to improve the number and quality of peptides detected by mass spectrometry (MS) is to desalt and concentrate proteolytic digests using reversed phase (RP) chromatography prior to analysis. However, this does not allow for detection of small or hydrophilic peptides......, or peptides altered in hydrophilicity such as phosphopeptides. We used microcolumns to compare the ability of RP resin or graphite powder to retain phosphopeptides. A number of standard phosphopeptides and a biologically relevant phosphoprotein, dynamin I, were analyzed. MS revealed that some phosphopeptides...

  2. A multistage, semi-automated procedure for analyzing the morphology of nanoparticles

    KAUST Repository

    Park, Chiwoo

    2012-07-01

    This article presents a multistage, semi-automated procedure that can expedite the morphology analysis of nanoparticles. Material scientists have long conjectured that the morphology of nanoparticles has a profound impact on the properties of the hosting material, but a bottleneck is the lack of a reliable and automated morphology analysis of the particles based on their image measurements. This article attempts to fill in this critical void. One particular challenge in nanomorphology analysis is how to analyze the overlapped nanoparticles, a problem not well addressed by the existing methods but effectively tackled by the method proposed in this article. This method entails multiple stages of operations, executed sequentially, and is considered semi-automated due to the inclusion of a semi-supervised clustering step. The proposed method is applied to several images of nanoparticles, producing the needed statistical characterization of their morphology. © 2012 "IIE".

  3. A multistage, semi-automated procedure for analyzing the morphology of nanoparticles

    KAUST Repository

    Park, Chiwoo; Huang, Jianhua Z.; Huitink, David; Kundu, Subrata; Mallick, Bani K.; Liang, Hong; Ding, Yu

    2012-01-01

    This article presents a multistage, semi-automated procedure that can expedite the morphology analysis of nanoparticles. Material scientists have long conjectured that the morphology of nanoparticles has a profound impact on the properties of the hosting material, but a bottleneck is the lack of a reliable and automated morphology analysis of the particles based on their image measurements. This article attempts to fill in this critical void. One particular challenge in nanomorphology analysis is how to analyze the overlapped nanoparticles, a problem not well addressed by the existing methods but effectively tackled by the method proposed in this article. This method entails multiple stages of operations, executed sequentially, and is considered semi-automated due to the inclusion of a semi-supervised clustering step. The proposed method is applied to several images of nanoparticles, producing the needed statistical characterization of their morphology. © 2012 "IIE".

  4. Micro-bead injection spectroscopy for label-free automated determination of immunoglobulin G in human serum.

    Science.gov (United States)

    Ramos, Inês I; Magalhães, Luís M; Barreiros, Luisa; Reis, Salette; Lima, José L F C; Segundo, Marcela A

    2018-01-01

    Immunoglobulin G (IgG) represents the major fraction of antibodies in healthy adult human serum, and deviations from physiological levels are a generic marker of disease corresponding to different pathologies. Therefore, screening methods for IgG evaluation are a valuable aid to diagnostics. The present work proposes a rapid, automatic, and miniaturized method based on UV-vis micro-bead injection spectroscopy (μ-BIS) for the real-time determination of human serum IgG with label-free detection. Relying on attachment of IgG in rec-protein G immobilized in Sepharose 4B, a bioaffinity column is automatically assembled, where IgG is selectively retained and determined by on-column optical density measurement. A "dilution-and-shoot" approach (50 to 200 times) was implemented without further sample treatment because interferences were flushed out of the column upon sample loading, with minimization of carryover and cross-contamination by automatically discarding the sorbent (0.2 mg) after each determination. No interference from human serum albumin at 60 mg mL -1 in undiluted sample was found. The method allowed IgG determination in the range 100-300 μg mL -1 (corresponding to 5.0-60 mg mL -1 in undiluted samples), with a detection limit of 33 μg mL -1 (1.7 mg mL -1 for samples, dilution factor of 50). RSD values were time-to-result decreased from several hours to times, showing the potential of the proposed approach as a point-of-care method. Graphical abstract Micro-Bead Injection Spectroscopy method for real time, automated and label-free determination of total serum human Immunoglobulin G (IgG). The method was designed for Lab-on-Valve (LOV) platforms using a miniaturised protein G bioaffinity separative approach. IgG are separated from serum matrix components upon quantification with low non-specific binding in less than 5 min.

  5. Interfacing sequential injection on-line preconcentration using a renewable micro-column incorporated in a ‘lab-on-valve’ system with direct injection nebulization inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2001-01-01

    the sampling frequency is 12 h-1. The precisions are 2.9% (0.8 mug l-1 Ni) and 1.7% (0.8 mug l-1 Bi), respectively. The procedure is validated by determination of nickel and bismuth in a certified reference material (CRM 320, River Sediment), and the recoveries are measured by spiking two human urine samples....

  6. Sequential Injection Chromatography with an Ultra-short Monolithic Column for the Low-Pressure Separation of α-Tocopherol and γ-Oryzanol in Vegetable Oils and Nutrition Supplements.

    Science.gov (United States)

    Thaithet, Sujitra; Kradtap Hartwell, Supaporn; Lapanantnoppakhun, Somchai

    2017-01-01

    A low-pressure separation procedure of α-tocopherol and γ-oryzanol was developed based on a sequential injection chromatography (SIC) system coupled with an ultra-short (5 mm) C-18 monolithic column, as a lower cost and more compact alternative to the HPLC system. A green sample preparation, dilution with a small amount of hexane followed by liquid-liquid extraction with 80% ethanol, was proposed. Very good separation resolution (R s = 3.26), a satisfactory separation time (10 min) and a total run time including column equilibration (16 min) were achieved. The linear working range was found to be 0.4 - 40 μg with R 2 being more than 0.99. The detection limits of both analytes were 0.28 μg with the repeatability within 5% RSD (n = 7). Quantitative analyses of the two analytes in vegetable oil and nutrition supplement samples, using the proposed SIC method, agree well with the results from HPLC.

  7. Efficient spin-current injection in single-molecule magnet junctions

    Directory of Open Access Journals (Sweden)

    Haiqing Xie

    2018-01-01

    Full Text Available We study theoretically spin transport through a single-molecule magnet (SMM in the sequential and cotunneling regimes, where the SMM is weakly coupled to one ferromagnetic and one normal-metallic leads. By a master-equation approach, it is found that the spin polarization injected from the ferromagnetic lead is amplified and highly polarized spin-current can be generated, due to the exchange coupling between the transport electron and the anisotropic spin of the SMM. Moreover, the spin-current polarization can be tuned by the gate or bias voltage, and thus an efficient spin injection device based on the SMM is proposed in molecular spintronics.

  8. Efficient spin-current injection in single-molecule magnet junctions

    Science.gov (United States)

    Xie, Haiqing; Xu, Fuming; Jiao, Hujun; Wang, Qiang; Liang, J.-Q.

    2018-01-01

    We study theoretically spin transport through a single-molecule magnet (SMM) in the sequential and cotunneling regimes, where the SMM is weakly coupled to one ferromagnetic and one normal-metallic leads. By a master-equation approach, it is found that the spin polarization injected from the ferromagnetic lead is amplified and highly polarized spin-current can be generated, due to the exchange coupling between the transport electron and the anisotropic spin of the SMM. Moreover, the spin-current polarization can be tuned by the gate or bias voltage, and thus an efficient spin injection device based on the SMM is proposed in molecular spintronics.

  9. Two-column sequential injection chromatography for fast isocratic separation of two analytes of greatly differing chemical properties.

    Science.gov (United States)

    Šatínský, Dalibor; Chocholouš, Petr; Válová, Olga; Hanusová, Lucia; Solich, Petr

    2013-09-30

    This paper deals with a novel approach to separate two analytes with different chemical properties and different lipophilicity. The newly described methodology is based on the two column system that was used for isocratic separation of two analytes with very different lipophilicity-dexamethasone and cinchocaine. Simultaneous separation of model compounds cinchocaine and dexamethasone was carried under the following conditions in two-column sequential injection chromatography system (2-C SIC). A 25×4.6 mm C-18 monolithic column was used in the first dimension for retention and separation of dexamethasone with mobile phase acetonitrile:water 30:70 (v/v), flow rate 0.9 mL min(-1) and consumption of 1.7 mL. A 10×4.6 mm C-18 monolithic column with 5×4.6 mm C-18 precolumn was used in the second dimension for retention and separation of cinchocaine using mobile phase acetonitrile:water 60:40 (v/v), flow rate 0.9 mL min(-1) and consumption 1.5 mL. Whole analysis time including both mobile phase's aspirations and both column separations was performed in less than 4 min. The method was fully validated and used for determination of cinchocaine and dexamethasone in pharmaceutical otic drops. The developed 2-C SIC method was compared with HPLC method under the isocratic conditions of separation on monolithic column (25×4.6 mm C-18). Spectrophotometric detection of both compounds was performed at wavelength 240 nm. System repeatability and method precision were found in the range (0.39-3.12%) for both compounds. Linearity of determination was evaluated in the range 50-500 μg mL(-1) and coefficients of determination were found to be r(2)=0.99912 for dexamethasone and r(2)=0.99969 for cinchocaine. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. A new dual injection system for AMS facility

    International Nuclear Information System (INIS)

    Liu Lin; Zhou Weijian; Cheng Peng; Yu Huagui; Chen Maobai

    2007-01-01

    In order to measure long-lived radioisotopes such as 10 Be with high sensitivity using an HVEE model 4130 AMS system, as well as to guarantee 14 C measurements of high precision, a new dual injection system for the AMS system is proposed. The proposal is to add a Wien filter located between the ion source system and the recombinator of the HVEE model 4130. When a pulsing voltage is optionally applied to the Wien filter, a sequential injection mode is turned on. The isotopes would alternately pass on different trajectories through the recombinator. When the pulsing voltage and magnetic field are turned off, the Wien filter acts as a field-free drift space and the standard simultaneous injection mode is on. Beam optics calculation show that the new dual injection system will increase the number of radio-nuclides which can be analyzed, keep the high precision capability for radiocarbon dating and achieve high sensitivity for 10 Be and 26 Al measurements, together with simplifying the layout as compared to existing dual-injector and dual high-energy beam line systems

  11. Evaluation of Coolant Injection Procedure in the Severe Accident Management Strategy of APR1400

    International Nuclear Information System (INIS)

    Cho, Yongjin; Lim, Kukhee; Song, Sungchu; Lee, Sukho; Hwang, Taesuk

    2013-01-01

    A coolant injection strategy in the severe accident management guideline (SAMG) of APR1400 relates to immediate coolant injection into RCS (Reactor Coolant System) or injection following the recovery of secondary coolant inventory. This strategy could play important role in accident mitigation and radiological consequences. In this study, appropriateness of the strategy was evaluated using MELCOR1.8.6 and several sensitivity studies of the key parameters were performed. Analysis for APR1400 using MELCOR 1.8.6 was performed to evaluate the effectiveness of accident management strategies and the following conclusions were identified. Sequential operation of secondary and RCS injection may not be the best strategy and the simultaneous injection of secondary and RCS injection could be more preferable. At least, the RCS injection should start before complete drainage of water in the safety injection tank using mobile pumps. In this study, the effectiveness of timing of operator action has been examined and the amount of injection flowrate needs to be studied in the future

  12. Computer automation of an accelerator mass spectrometry system

    International Nuclear Information System (INIS)

    Gressett, J.D.; Maxson, D.L.; Matteson, S.; McDaniel, F.D.; Duggan, J.L.; Mackey, H.J.; North Texas State Univ., Denton, TX; Anthony, J.M.

    1989-01-01

    The determination of trace impurities in electronic materials using accelerator mass spectrometry (AMS) requires efficient automation of the beam transport and mass discrimination hardware. The ability to choose between a variety of charge states, isotopes and injected molecules is necessary to provide survey capabilities similar to that available on conventional mass spectrometers. This paper will discuss automation hardware and software for flexible, high-sensitivity trace analysis of electronic materials, e.g. Si, GaAs and HgCdTe. Details regarding settling times will be presented, along with proof-of-principle experimental data. Potential and present applications will also be discussed. (orig.)

  13. Successful outcome after intravenous gasoline injection.

    Science.gov (United States)

    Domej, Wolfgang; Mitterhammer, Heike; Stauber, Rudolf; Kaufmann, Peter; Smolle, Karl Heinz

    2007-12-01

    Gasoline, ingested intentionally or accidentally, is toxic. The majority of reported cases of gasoline intoxication involve oral ingestion or inhalation. Data are scarce on complications and outcomes following hydrocarbon poisoning by intravenous injection. Following a suicide attempt by intravenous self-injection of 10 ml of gasoline, a 26-year-old medical student was admitted to the intensive care unit (ICU) with hemoptysis, symptoms of acute respiratory failure, chest pain, and severe abdominal cramps. Gas exchange was severely impaired and a chest x-ray indicated chemical pneumonitis. Initial treatment consisted of mechanical ventilation, supportive hyperventilation, administration of nitrogen oxide (NO), and prednisone. Unfortunately, the patient developed multi-organ dysfunction syndrome (MODS) complicated by life-threatening severe vasoplegia within 24 hours after gasoline injection. High doses of vasopressors along with massive amounts of parenteral fluids were necessary. Despite fluid replacement, renal function worsened and required hemofiltration on 5 sequential days. After 12 days of intensive care management, the patient recovered completely and was discharged to a psychiatric care facility. Intravenous gasoline injection causes major injury to the lungs, the organ bearing the first capillary bed encountered. Treatment of gasoline poisoning is symptomatic because no specific antidote is available. Early and aggressive supportive care may be conducive to a favorable outcome with minimal residual pulmonary sequelae.

  14. Development of flow injection analysis technique for uranium estimation

    International Nuclear Information System (INIS)

    Paranjape, A.H.; Pandit, S.S.; Shinde, S.S.; Ramanujam, A.; Dhumwad, R.K.

    1991-01-01

    Flow injection analysis is increasingly used as a process control analytical technique in many industries. It involves injection of the sample at a constant rate into a steady flowing stream of reagent and passing this mixture through a suitable detector. This paper describes the development of such a system for the analysis of uranium (VI) and (IV) and its gross gamma activity. It is amenable for on-line or automated off-line monitoring of uranium and its activity in process streams. The sample injection port is suitable for automated injection of radioactive samples. The performance of the system has been tested for the colorimetric response of U(VI) samples at 410 nm in the range of 35 to 360mg/ml in nitric acid medium using Metrohm 662 Photometer and a recorder as detector assembly. The precision of the method is found to be better than +/- 0.5%. This technique with certain modifications is used for the analysis of U(VI) in the range 0.1-3mg/ailq. by alcoholic thiocynate procedure within +/- 1.5% precision. Similarly the precision for the determination of U(IV) in the range 15-120 mg at 650 nm is found to be better than 5%. With NaI well-type detector in the flow line, the gross gamma counting of the solution under flow is found to be within a precision of +/- 5%. (author). 4 refs., 2 figs., 1 tab

  15. Determination of trace heavy metals in herbs by sequential injection analysis-anodic stripping voltammetry using screen-printed carbon nanotubes electrodes

    International Nuclear Information System (INIS)

    Injang, Uthaitip; Noyrod, Peeyanun; Siangproh, Weena; Dungchai, Wijitar; Motomizu, Shoji; Chailapakul, Orawon

    2010-01-01

    A method for the simultaneous determination of Pb(II), Cd(II), and Zn(II) at low μg L -1 concentration levels by sequential injection analysis-anodic stripping voltammetry (SIA-ASV) using screen-printed carbon nanotubes electrodes (SPCNTE) was developed. A bismuth film was prepared by in situ plating of bismuth on the screen-printed carbon nanotubes electrode. Operational parameters such as ratio of carbon nanotubes to carbon ink, bismuth concentration, deposition time and flow rate during preconcentration step were optimized. Under the optimal conditions, the linear ranges were found to be 2-100 μg L -1 for Pb(II) and Cd(II), and 12-100 μg L -1 for Zn(II). The limits of detection (S bl /S = 3) were 0.2 μg L -1 for Pb(II), 0.8 μg L -1 for Cd(II) and 11 μg L -1 for Zn(II). The measurement frequency was found to be 10-15 stripping cycle h -1 . The present method offers high sensitivity and high throughput for on-line monitoring of trace heavy metals. The practical utility of our method was also demonstrated with the determination of Pb(II), Cd(II), and Zn(II) by spiking procedure in herb samples. Our methodology produced results that were correlated with ICP-AES data. Therefore, we propose a method that can be used for the automatic and sensitive evaluation of heavy metals contaminated in herb items.

  16. Sequentially optimized reconstruction strategy: A meta-strategy for perimetry testing.

    Directory of Open Access Journals (Sweden)

    Şerife Seda Kucur

    Full Text Available Perimetry testing is an automated method to measure visual function and is heavily used for diagnosing ophthalmic and neurological conditions. Its working principle is to sequentially query a subject about perceived light using different brightness levels at different visual field locations. At a given location, this query-patient-feedback process is expected to converge at a perceived sensitivity, such that a shown stimulus intensity is observed and reported 50% of the time. Given this inherently time-intensive and noisy process, fast testing strategies are necessary in order to measure existing regions more effectively and reliably. In this work, we present a novel meta-strategy which relies on the correlative nature of visual field locations in order to strongly reduce the necessary number of locations that need to be examined. To do this, we sequentially determine locations that most effectively reduce visual field estimation errors in an initial training phase. We then exploit these locations at examination time and show that our approach can easily be combined with existing perceived sensitivity estimation schemes to speed up the examinations. Compared to state-of-the-art strategies, our approach shows marked performance gains with a better accuracy-speed trade-off regime for both mixed and sub-populations.

  17. Automated detection of cavities present in the high explosive filler of artillery shells

    International Nuclear Information System (INIS)

    Kruger, R.P.; Janney, D.H.; Breedlove, J.R. Jr.

    1976-01-01

    Initial research has been conducted into the use of digital image analysis techniques for automated detection and characterization of piping cavities present in the high explosive (HE) filler region of 105-mm artillery shells. Experimental work utilizing scene segmentation techniques followed by a sequential similarity detection algorithm for cavitation detection have yielded promising initial results. This work is described with examples of computer-detected defects

  18. Modelling sequentially scored item responses

    NARCIS (Netherlands)

    Akkermans, W.

    2000-01-01

    The sequential model can be used to describe the variable resulting from a sequential scoring process. In this paper two more item response models are investigated with respect to their suitability for sequential scoring: the partial credit model and the graded response model. The investigation is

  19. Method for semi-automated microscopy of filtration-enriched circulating tumor cells

    International Nuclear Information System (INIS)

    Pailler, Emma; Oulhen, Marianne; Billiot, Fanny; Galland, Alexandre; Auger, Nathalie; Faugeroux, Vincent; Laplace-Builhé, Corinne; Besse, Benjamin; Loriot, Yohann; Ngo-Camus, Maud; Hemanda, Merouan; Lindsay, Colin R.; Soria, Jean-Charles; Vielh, Philippe; Farace, Françoise

    2016-01-01

    Circulating tumor cell (CTC)-filtration methods capture high numbers of CTCs in non-small-cell lung cancer (NSCLC) and metastatic prostate cancer (mPCa) patients, and hold promise as a non-invasive technique for treatment selection and disease monitoring. However filters have drawbacks that make the automation of microscopy challenging. We report the semi-automated microscopy method we developed to analyze filtration-enriched CTCs from NSCLC and mPCa patients. Spiked cell lines in normal blood and CTCs were enriched by ISET (isolation by size of epithelial tumor cells). Fluorescent staining was carried out using epithelial (pan-cytokeratins, EpCAM), mesenchymal (vimentin, N-cadherin), leukocyte (CD45) markers and DAPI. Cytomorphological staining was carried out with Mayer-Hemalun or Diff-Quik. ALK-, ROS1-, ERG-rearrangement were detected by filter-adapted-FISH (FA-FISH). Microscopy was carried out using an Ariol scanner. Two combined assays were developed. The first assay sequentially combined four-color fluorescent staining, scanning, automated selection of CD45 − cells, cytomorphological staining, then scanning and analysis of CD45 − cell phenotypical and cytomorphological characteristics. CD45 − cell selection was based on DAPI and CD45 intensity, and a nuclear area >55 μm 2 . The second assay sequentially combined fluorescent staining, automated selection of CD45 − cells, FISH scanning on CD45 − cells, then analysis of CD45 − cell FISH signals. Specific scanning parameters were developed to deal with the uneven surface of filters and CTC characteristics. Thirty z-stacks spaced 0.6 μm apart were defined as the optimal setting, scanning 82 %, 91 %, and 95 % of CTCs in ALK-, ROS1-, and ERG-rearranged patients respectively. A multi-exposure protocol consisting of three separate exposure times for green and red fluorochromes was optimized to analyze the intensity, size and thickness of FISH signals. The semi-automated microscopy method reported here

  20. LAVA: Large scale Automated Vulnerability Addition

    Science.gov (United States)

    2016-05-23

    LAVA: Large-scale Automated Vulnerability Addition Brendan Dolan -Gavitt∗, Patrick Hulin†, Tim Leek†, Fredrich Ulrich†, Ryan Whelan† (Authors listed...released, and thus rapidly become stale. We can expect tools to have been trained to detect bugs that have been released. Given the commercial price tag...low TCN) and dead (low liveness) program data is a powerful one for vulnera- bility injection. The DUAs it identifies are internal program quantities

  1. Multi-agent sequential hypothesis testing

    KAUST Repository

    Kim, Kwang-Ki K.

    2014-12-15

    This paper considers multi-agent sequential hypothesis testing and presents a framework for strategic learning in sequential games with explicit consideration of both temporal and spatial coordination. The associated Bayes risk functions explicitly incorporate costs of taking private/public measurements, costs of time-difference and disagreement in actions of agents, and costs of false declaration/choices in the sequential hypothesis testing. The corresponding sequential decision processes have well-defined value functions with respect to (a) the belief states for the case of conditional independent private noisy measurements that are also assumed to be independent identically distributed over time, and (b) the information states for the case of correlated private noisy measurements. A sequential investment game of strategic coordination and delay is also discussed as an application of the proposed strategic learning rules.

  2. Silhouette-based approach of 3D image reconstruction for automated image acquisition using robotic arm

    Science.gov (United States)

    Azhar, N.; Saad, W. H. M.; Manap, N. A.; Saad, N. M.; Syafeeza, A. R.

    2017-06-01

    This study presents the approach of 3D image reconstruction using an autonomous robotic arm for the image acquisition process. A low cost of the automated imaging platform is created using a pair of G15 servo motor connected in series to an Arduino UNO as a main microcontroller. Two sets of sequential images were obtained using different projection angle of the camera. The silhouette-based approach is used in this study for 3D reconstruction from the sequential images captured from several different angles of the object. Other than that, an analysis based on the effect of different number of sequential images on the accuracy of 3D model reconstruction was also carried out with a fixed projection angle of the camera. The effecting elements in the 3D reconstruction are discussed and the overall result of the analysis is concluded according to the prototype of imaging platform.

  3. Sequential charged particle reaction

    International Nuclear Information System (INIS)

    Hori, Jun-ichi; Ochiai, Kentaro; Sato, Satoshi; Yamauchi, Michinori; Nishitani, Takeo

    2004-01-01

    The effective cross sections for producing the sequential reaction products in F82H, pure vanadium and LiF with respect to the 14.9-MeV neutron were obtained and compared with the estimation ones. Since the sequential reactions depend on the secondary charged particles behavior, the effective cross sections are corresponding to the target nuclei and the material composition. The effective cross sections were also estimated by using the EAF-libraries and compared with the experimental ones. There were large discrepancies between estimated and experimental values. Additionally, we showed the contribution of the sequential reaction on the induced activity and dose rate in the boundary region with water. From the present study, it has been clarified that the sequential reactions are of great importance to evaluate the dose rates around the surface of cooling pipe and the activated corrosion products. (author)

  4. Rapid and automated determination of plutonium and neptunium in environmental samples

    International Nuclear Information System (INIS)

    Qiao, J.

    2011-03-01

    This thesis presents improved analytical methods for rapid and automated determination of plutonium and neptunium in environmental samples using sequential injection (SI) based chromatography and inductively coupled plasma mass spectrometry (ICP-MS). The progress of methodology development in this work consists of 5 subjects stated as follows: 1) Development and optimization of an SI-anion exchange chromatographic method for rapid determination of plutonium in environmental samples in combination of inductively coupled plasma mass spectrometry detection (Paper II); (2) Methodology development and optimization for rapid determination of plutonium in environmental samples using SI-extraction chromatography prior to inductively coupled plasma mass spectrometry (Paper III); (3) Development of an SI-chromatographic method for simultaneous determination of plutonium and neptunium in environmental samples (Paper IV); (4) Investigation of the suitability and applicability of 242 Pu as a tracer for rapid neptunium determination using anion exchange chromatography in an SI-network coupled with inductively coupled plasma mass spectrometry (Paper V); (5) Exploration of macro-porous anion exchange chromatography for rapid and simultaneous determination of plutonium and neptunium within an SI system (Paper VI). The results demonstrate that the developed methods in this study are reliable and efficient for accurate assays of trace levels of plutonium and neptunium as demanded in different situations including environmental risk monitoring and assessment, emergency preparedness and surveillance of contaminated areas. (Author)

  5. Rapid and automated determination of plutonium and neptunium in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Qiao, J.

    2011-03-15

    This thesis presents improved analytical methods for rapid and automated determination of plutonium and neptunium in environmental samples using sequential injection (SI) based chromatography and inductively coupled plasma mass spectrometry (ICP-MS). The progress of methodology development in this work consists of 5 subjects stated as follows: 1) Development and optimization of an SI-anion exchange chromatographic method for rapid determination of plutonium in environmental samples in combination of inductively coupled plasma mass spectrometry detection (Paper II); (2) Methodology development and optimization for rapid determination of plutonium in environmental samples using SI-extraction chromatography prior to inductively coupled plasma mass spectrometry (Paper III); (3) Development of an SI-chromatographic method for simultaneous determination of plutonium and neptunium in environmental samples (Paper IV); (4) Investigation of the suitability and applicability of 242Pu as a tracer for rapid neptunium determination using anion exchange chromatography in an SI-network coupled with inductively coupled plasma mass spectrometry (Paper V); (5) Exploration of macro-porous anion exchange chromatography for rapid and simultaneous determination of plutonium and neptunium within an SI system (Paper VI). The results demonstrate that the developed methods in this study are reliable and efficient for accurate assays of trace levels of plutonium and neptunium as demanded in different situations including environmental risk monitoring and assessment, emergency preparedness and surveillance of contaminated areas. (Author)

  6. Sequential Therapy of Community-Acquired Pneumonia in Children

    Directory of Open Access Journals (Sweden)

    I.A. Karimdzhanov

    2014-04-01

    Full Text Available Aim of the study — to examine the effectiveness of sequential therapy of injectable and oral forms cephalosporins of II generation, cefuroxime sodium and cefprozil, in children with acute community-acquired pneumonia. We examined 53 child patients aged 6 months — 14 years with acute community-acquired pneumonia. Patients were divided into 2 groups: 1st group — 26 patients who treated with cefuroxime sodium intramuscularly, and 2nd — 27 patients who treated with cefuroxime sodium in first 3 days and then from the 4th day — with cefprozil suspension orally. Both groups of patients were comparable by forms and course of pneumonia. In the clinic to all patients were conducted conventional clinical and laboratory investigations. Complex therapy was not different in both groups. Efficacy of treatment was assessed in dynamics. When comparing the effectiveness of two antibiotic regimens (cefuroxime sodium parenterally and sequential regimen with replacement by cefprozil orally there were no differences in the dynamics of clinical course, laboratory and radiological data. Finding of the conducted investigations before treatment showed that majority of patients had clinical and radiological evidence of pneumonia: fever, cough, shortness of breath, tachycardia, physical and radiological changes in the lungs. Evaluation of treatment efficacy showed that by the end of treatment in both groups of patients there was a positive clinical and radiological dynamics of the disease, the body temperature returned to normal, symptoms of intoxication, physical changes in the lungs disappeared, focal and infiltrative changes disappeared completely. Thus, sequential therapy with cephalosporins of II generation, cefuroxime and cefprozil, in the treatment of acute community-acquired pneumonia in children is a quite effective and safe method with good tolerability and no side effects.

  7. Corpus Callosum Analysis using MDL-based Sequential Models of Shape and Appearance

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Davies, Rhodri H.; Ryberg, Charlotte

    2004-01-01

    are proposed, but all remain applicable to other domain problems. The well-known multi-resolution AAM optimisation is extended to include sequential relaxations on texture resolution, model coverage and model parameter constraints. Fully unsupervised analysis is obtained by exploiting model parameter...... that show that the method produces accurate, robust and rapid segmentations in a cross sectional study of 17 subjects, establishing its feasibility as a fully automated clinical tool for analysis and segmentation.......This paper describes a method for automatically analysing and segmenting the corpus callosum from magnetic resonance images of the brain based on the widely used Active Appearance Models (AAMs) by Cootes et al. Extensions of the original method, which are designed to improve this specific case...

  8. Eyewitness confidence in simultaneous and sequential lineups: a criterion shift account for sequential mistaken identification overconfidence.

    Science.gov (United States)

    Dobolyi, David G; Dodson, Chad S

    2013-12-01

    Confidence judgments for eyewitness identifications play an integral role in determining guilt during legal proceedings. Past research has shown that confidence in positive identifications is strongly associated with accuracy. Using a standard lineup recognition paradigm, we investigated accuracy using signal detection and ROC analyses, along with the tendency to choose a face with both simultaneous and sequential lineups. We replicated past findings of reduced rates of choosing with sequential as compared to simultaneous lineups, but notably found an accuracy advantage in favor of simultaneous lineups. Moreover, our analysis of the confidence-accuracy relationship revealed two key findings. First, we observed a sequential mistaken identification overconfidence effect: despite an overall reduction in false alarms, confidence for false alarms that did occur was higher with sequential lineups than with simultaneous lineups, with no differences in confidence for correct identifications. This sequential mistaken identification overconfidence effect is an expected byproduct of the use of a more conservative identification criterion with sequential than with simultaneous lineups. Second, we found a steady drop in confidence for mistaken identifications (i.e., foil identifications and false alarms) from the first to the last face in sequential lineups, whereas confidence in and accuracy of correct identifications remained relatively stable. Overall, we observed that sequential lineups are both less accurate and produce higher confidence false identifications than do simultaneous lineups. Given the increasing prominence of sequential lineups in our legal system, our data argue for increased scrutiny and possibly a wholesale reevaluation of this lineup format. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  9. Preconcentration and speciation of chromium in a sequential injection system incorporating dual mini-columns coupled with electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zou Aimei; Tang Xiaoyan; Chen Mingli [Research Center for Analytical Sciences, Northeastern University, Box 332, Shenyang 110004 (China); Wang Jianhua [Research Center for Analytical Sciences, Northeastern University, Box 332, Shenyang 110004 (China)], E-mail: jianhuajrz@mail.neu.edu.cn

    2008-05-15

    A procedure for chromium preconcentration and speciation with a dual mini-column sequential injection system coupled with electrothermal atomic absorption spectrometry (ETAAS) was developed. At pH 6, the sample solution was firstly aspirated to flow through a Chlorella vulgaris cell mini-column on which the Cr(III) was retained. The effluent was afterwards directed to flow through a 717 anion exchange resin mini-column accompanied by the retention of Cr(VI). Thereafter, Cr(III) and Cr(VI) were eluted by 0.04 mol L{sup -1} and 1.0 mol L{sup -1} nitric acid, respectively, and the eluates were quantified with ETAAS. Chemical and flow variables governing the performance of the system were investigated. By using a sampling volume of 600 {mu}L, sorption efficiencies of 99.7% for Cr(III) and 99% for Cr(VI) were achieved along with enrichment factors of 10.5 for Cr(III) and 11.6 for Cr(VI), within linear ranges of 0.1-2.5 {mu}g L{sup -1} for Cr(III) and 0.12-2.0 {mu}g L{sup -1} for Cr(VI). Detection limits of 0.02 {mu}g L{sup -1} for Cr(III) and 0.03 {mu}g L{sup -1} for Cr(VI) along with RSD values of 1.9% for Cr(III) and 2.5% for Cr(VI) (1.0 {mu}g L{sup -1}, n = 11) were obtained. The procedure was validated by analyzing a certified reference material of GBW08608 and further demonstrated by chromium speciation in river and tap water samples.

  10. On-line liquid phase micro-extraction based on drop-in-plug sequential injection lab-at-valve platform for metal determination

    Energy Technology Data Exchange (ETDEWEB)

    Mitani, Constantina [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, Thessaloniki 54124 (Greece); Anthemidis, Aristidis N., E-mail: anthemid@chem.auth.gr [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, Thessaloniki 54124 (Greece)

    2013-04-10

    Highlights: ► Drop-in-plug micro-extraction based on SI-LAV platform for metal preconcentration. ► Automatic liquid phase micro-extraction coupled with FAAS. ► Organic solvents with density higher than water are used. ► Lead determination in environmental water and urine samples. -- Abstract: A novel automatic on-line liquid phase micro-extraction method based on drop-in-plug sequential injection lab-at-valve (LAV) platform was proposed for metal preconcentration and determination. A flow-through micro-extraction chamber mounted at the selection valve was adopted without the need of sophisticated lab-on-valve components. Coupled to flame atomic absorption spectrometry (FAAS), the potential of this lab-at-valve scheme is demonstrated for trace lead determination in environmental and biological water samples. A hydrophobic complex of lead with ammonium pyrrolidine dithiocarbamate (APDC) was formed on-line and subsequently extracted into an 80 μL plug of chloroform. The extraction procedure was performed by forming micro-droplets of aqueous phase into the plug of the extractant. All critical parameters that affect the efficiency of the system were studied and optimized. The proposed method offered good performance characteristics and high preconcentration ratios. For 10 mL sample consumption an enhancement factor of 125 was obtained. The detection limit was 1.8 μg L{sup −1} and the precision expressed as relative standard deviation (RSD) at 50.0 μg L{sup −1} of lead was 2.9%. The proposed method was evaluated by analyzing certified reference materials and applied for lead determination in natural waters and urine samples.

  11. INVESTIGATION OF NEURAL NETWORK ALGORITHM FOR DETECTION OF NETWORK HOST ANOMALIES IN THE AUTOMATED SEARCH FOR XSS VULNERABILITIES AND SQL INJECTIONS

    Directory of Open Access Journals (Sweden)

    Y. D. Shabalin

    2016-03-01

    Full Text Available A problem of aberrant behavior detection for network communicating computer is discussed. A novel approach based on dynamic response of computer is introduced. The computer is suggested as a multiple-input multiple-output (MIMO plant. To characterize dynamic response of the computer on incoming requests a correlation between input data rate and observed output response (outgoing data rate and performance metrics is used. To distinguish normal and aberrant behavior of the computer one-class neural network classifieris used. General idea of the algorithm is shortly described. Configuration of network testbed for experiments with real attacks and their detection is presented (the automated search for XSS and SQL injections. Real found-XSS and SQL injection attack software was used to model the intrusion scenario. It would be expectable that aberrant behavior of the server will reveal itself by some instantaneous correlation response which will be significantly different from any of normal ones. It is evident that correlation picture of attacks from different malware running, the site homepage overriding on the server (so called defacing, hardware and software failures will differ from correlation picture of normal functioning. Intrusion detection algorithm is investigated to estimate false positive and false negative rates in relation to algorithm parameters. The importance of correlation width value and threshold value selection was emphasized. False positive rate was estimated along the time series of experimental data. Some ideas about enhancement of the algorithm quality and robustness were mentioned.

  12. Flexible automated approach for quantitative liquid handling of complex biological samples.

    Science.gov (United States)

    Palandra, Joe; Weller, David; Hudson, Gary; Li, Jeff; Osgood, Sarah; Hudson, Emily; Zhong, Min; Buchholz, Lisa; Cohen, Lucinda H

    2007-11-01

    A fully automated protein precipitation technique for biological sample preparation has been developed for the quantitation of drugs in various biological matrixes. All liquid handling during sample preparation was automated using a Hamilton MicroLab Star Robotic workstation, which included the preparation of standards and controls from a Watson laboratory information management system generated work list, shaking of 96-well plates, and vacuum application. Processing time is less than 30 s per sample or approximately 45 min per 96-well plate, which is then immediately ready for injection onto an LC-MS/MS system. An overview of the process workflow is discussed, including the software development. Validation data are also provided, including specific liquid class data as well as comparative data of automated vs manual preparation using both quality controls and actual sample data. The efficiencies gained from this automated approach are described.

  13. A MEMS lamination technology based on sequential multilayer electrodeposition

    International Nuclear Information System (INIS)

    Kim, Minsoo; Kim, Jooncheol; Herrault, Florian; Schafer, Richard; Allen, Mark G

    2013-01-01

    A MEMS lamination technology based on sequential multilayer electrodeposition is presented. The process comprises three main steps: (1) automated sequential electrodeposition of permalloy (Ni 80 Fe 20 ) structural and copper sacrificial layers to form multilayer structures of significant total thickness; (2) fabrication of polymeric anchor structures through the thickness of the multilayer structures and (3) selective removal of copper. The resulting structure is a set of air-insulated permalloy laminations, the separation of which is sustained by insulating polymeric anchor structures. Individual laminations have precisely controllable thicknesses ranging from 500 nm to 5 µm, and each lamination layer is electrically isolated from adjacent layers by narrow air gaps of similar scale. In addition to air, interlamination insulators based on polymers are investigated. Interlamination air gaps with very high aspect ratio (>1:100) can be filled with polyvinylalcohol and polydimethylsiloxane. The laminated structures are characterized using scanning electron microscopy and atomic force microscopy to directly examine properties such as the roughness and the thickness uniformity of the layers. In addition, the quality of the electrical insulation between the laminations is evaluated by quantifying the eddy current within the sample as a function of frequency. Fabricated laminations are comprised of uniform, smooth (surface roughness <100 nm) layers with effective electrical insulation for all layer thicknesses and insulator approaches studied. Such highly laminated structures have potential uses ranging from energy conversion to applications where composite materials with highly anisotropic mechanical or thermal properties are required. (paper)

  14. Application of a path sensitizing method on automated generation of test specifications for control software

    International Nuclear Information System (INIS)

    Morimoto, Yuuichi; Fukuda, Mitsuko

    1995-01-01

    An automated generation method for test specifications has been developed for sequential control software in plant control equipment. Sequential control software can be represented as sequential circuits. The control software implemented in a control equipment is designed from these circuit diagrams. In logic tests of VLSI's, path sensitizing methods are widely used to generate test specifications. But the method generates test specifications at a single time only, and can not be directly applied to sequential control software. The basic idea of the proposed method is as follows. Specifications of each logic operator in the diagrams are defined in the software design process. Therefore, test specifications of each operator in the control software can be determined from these specifications, and validity of software can be judged by inspecting all of the operators in the logic circuit diagrams. Candidates for sensitized paths, on which test data for each operator propagates, can be generated by the path sensitizing method. To confirm feasibility of the method, it was experimentally applied to control software in digital control equipment. The program could generate test specifications exactly, and feasibility of the method was confirmed. (orig.) (3 refs., 7 figs.)

  15. Advances in the physics modelling of CANDU liquid injection shutdown systems

    International Nuclear Information System (INIS)

    Smith, H.J.; Robinson, R.; Guertin, C.

    1993-01-01

    The physics modelling of liquid poison injection shutdown systems in CANDU reactors accounts for the major phenomena taking place by combining the effects of both moderator hydraulics and neutronics. This paper describes the advances in the physics modelling of liquid poison injection shutdown systems (LISS), discusses some of the effects of the more realistic modelling, and briefly describes the automation methodology. Modifications to the LISS methodology have improved the realism of the physics modelling, showing that the previous methodology significantly overestimated energy deposition during the simulation of a loss of coolant transient in Bruce A, by overestimating the reactivity transient. Furthermore, the automation of the modelling process has reduced the time needed to carry put LISS evaluations to the same level as required for shutoff-rod evaluations, while at the same time minimizing the amount of input, and providing a method for tracing all files used, thus adding a level of quality assurance to the calculation. 5 refs., 11 figs

  16. Constrained treatment planning using sequential beam selection

    International Nuclear Information System (INIS)

    Woudstra, E.; Storchi, P.R.M.

    2000-01-01

    In this paper an algorithm is described for automated treatment plan generation. The algorithm aims at delivery of the prescribed dose to the target volume without violation of constraints for target, organs at risk and the surrounding normal tissue. Pre-calculated dose distributions for all candidate orientations are used as input. Treatment beams are selected in a sequential way. A score function designed for beam selection is used for the simultaneous selection of beam orientations and weights. In order to determine the optimum choice for the orientation and the corresponding weight of each new beam, the score function is first redefined to account for the dose distribution of the previously selected beams. Addition of more beams to the plan is stopped when the target dose is reached or when no additional dose can be delivered without violating a constraint. In the latter case the score function is modified by importance factor changes to enforce better sparing of the organ with the limiting constraint and the algorithm is run again. (author)

  17. Remarks on sequential designs in risk assessment

    International Nuclear Information System (INIS)

    Seidenfeld, T.

    1982-01-01

    The special merits of sequential designs are reviewed in light of particular challenges that attend risk assessment for human population. The kinds of ''statistical inference'' are distinguished and the problem of design which is pursued is the clash between Neyman-Pearson and Bayesian programs of sequential design. The value of sequential designs is discussed and the Neyman-Pearson vs. Bayesian sequential designs are probed in particular. Finally, warnings with sequential designs are considered, especially in relation to utilitarianism

  18. Automated tuning of the advanced photon source booster synchrotron

    International Nuclear Information System (INIS)

    Biedron, S.G.; Milton, S.V.

    1997-01-01

    The acceleration cycle of the Advanced Photon Source (APS) booster synchrotron is completed within 223 ms and is repeated at 2 Hz. Unless properly corrected, transverse and longitudinal injection errors can lead to inefficient booster performance. In order to simplify daily operation, automated tuning methods have been developed. Through the use of beam position monitor (BPM) reading, transfer line corrector magnets, magnet ramp timing, and empirically determined response functions, the injection process is optimized by correcting the first turn trajectory to the measured closed orbit. These tuning algorithms and their implementation are described here along with an evaluation of their performance

  19. MELCOR assessment of sequential severe accident mitigation actions under SGTR accident

    International Nuclear Information System (INIS)

    Choi, Wonjun; Jeon, Joongoo; Kim, Nam Kyung; Kim, Sung Joong

    2017-01-01

    The representative example of the severe accident studies using the severe accident code is investigation of effectiveness of developed severe accident management (SAM) strategy considering the positive and adverse effects. In Korea, some numerical studies were performed to investigate the SAM strategy using various severe accident codes. Seo et.al performed validation of RCS depressurization strategy and investigated the effect of severe accident management guidance (SAMG) entry condition under small break loss of coolant accident (SBLOCA) without safety injection (SI), station blackout (SBO), and total loss of feed water (TLOFW) scenarios. The SGTR accident with the sequential mitigation actions according to the flow chart of SAMG was simulated by the MELCOR 1.8.6 code. Three scenariospreventing the RPV failure were investigated in terms of fission product release, hydrogen risk, and the containment pressure. Major conclusions can be summarized as follows: (1) According to the flow chart of SAMG, RPV failure can be prevented depending on the method of RCS depressurization. (2) To reduce the release of fission product during the injecting into SGs, a temporary opening of SDS before the injecting into SGs was suggested. These modified sequences of mitigation actions can reduce the release of fission product and the adverse effect of SDS.

  20. Sequential lineup laps and eyewitness accuracy.

    Science.gov (United States)

    Steblay, Nancy K; Dietrich, Hannah L; Ryan, Shannon L; Raczynski, Jeanette L; James, Kali A

    2011-08-01

    Police practice of double-blind sequential lineups prompts a question about the efficacy of repeated viewings (laps) of the sequential lineup. Two laboratory experiments confirmed the presence of a sequential lap effect: an increase in witness lineup picks from first to second lap, when the culprit was a stranger. The second lap produced more errors than correct identifications. In Experiment 2, lineup diagnosticity was significantly higher for sequential lineup procedures that employed a single versus double laps. Witnesses who elected to view a second lap made significantly more errors than witnesses who chose to stop after one lap or those who were required to view two laps. Witnesses with prior exposure to the culprit did not exhibit a sequential lap effect.

  1. Automated Cell-Cutting for Cell Cloning

    Science.gov (United States)

    Ichikawa, Akihiko; Tanikawa, Tamio; Matsukawa, Kazutsugu; Takahashi, Seiya; Ohba, Kohtaro

    We develop an automated cell-cutting technique for cell cloning. Animal cells softened by the cytochalasin treatment are injected into a microfluidic chip. The microfluidic chip contains two orthogonal channels: one microchannel is wide, used to transport cells, and generates the cutting flow; the other is thin and used for aspiration, fixing, and stretching of the cell. The injected cell is aspirated and stretched in the thin microchannel. Simultaneously, the volumes of the cell before and after aspiration are calculated; the volumes are used to calculate the fluid flow required to aspirate half the volume of the cell into the thin microchannel. Finally, we apply a high-speed flow in the orthogonal microchannel to bisect the cell. This paper reports the cutting process, the cutting system, and the results of the experiment.

  2. Robustness of the Sequential Lineup Advantage

    Science.gov (United States)

    Gronlund, Scott D.; Carlson, Curt A.; Dailey, Sarah B.; Goodsell, Charles A.

    2009-01-01

    A growing movement in the United States and around the world involves promoting the advantages of conducting an eyewitness lineup in a sequential manner. We conducted a large study (N = 2,529) that included 24 comparisons of sequential versus simultaneous lineups. A liberal statistical criterion revealed only 2 significant sequential lineup…

  3. Microcellular injection molding process for producing lightweight thermoplastic polyurethane with customizable properties

    Science.gov (United States)

    Ellingham, Thomas; Kharbas, Hrishikesh; Manitiu, Mihai; Scholz, Guenter; Turng, Lih-Sheng

    2018-03-01

    A three-stage molding process involving microcellular injection molding with core retraction and an "out-of-mold" expansion was developed to manufacture thermoplastic polyurethane into lightweight foams of varying local densities, microstructures, and mechanical properties in the same microcellular injection molded part. Two stages of cavity expansion through sequential core retractions and a third expansion in a separate mold at an elevated temperature were carried out. The densities varied from 0.25 to 0.42 g/cm3 (77% to 62% weight reduction). The mechanical properties varied as well. Cyclic compressive strengths and hysteresis loss ratios, together with the microstructures, were characterized and reported.

  4. Studies in Fat Grafting: Part I. Effects of Injection Technique on in vitro Fat Viability and in vivo Volume Retention

    Science.gov (United States)

    Chung, Michael T.; Paik, Kevin J.; Atashroo, David A.; Hyun, Jeong S.; McArdle, Adrian; Senarath-Yapa, Kshemendra; Zielins, Elizabeth R.; Tevlin, Ruth; Duldulao, Chris; Hu, Michael S.; Walmsley, Graham G.; Parisi-Amon, Andreina; Momeni, Arash; Rimsa, Joe R.; Commons, George W.; Gurtner, Geoffrey C.; Wan, Derrick C.; Longaker, Michael T.

    2014-01-01

    Background Fat grafting has become increasingly popular for the correction of soft tissue deficits at many sites throughout the body. Long-term outcomes, however, depend on delivery of fat in the least traumatic fashion to optimize viability of the transplanted tissue. In this study, we compare the biologic properties of fat following injection using two methods. Methods Lipoaspiration samples were obtained from five female donors and cellular viability, proliferation, and lipolysis were evaluated following injection using either a modified Coleman technique or an automated, low shear device. Comparisons were made to minimally processed, uninjected fat. Volume retention was also measured over twelve weeks following injection of fat under the scalp of immunodeficient mice using either the modified Coleman technique or the Adipose Tissue Injector. Finally, fat grafts were analyzed histologically. Results Fat viability and cellular proliferation were both significantly greater with the Adipose Tissue Injector relative to injection with the modified Coleman technique. In contrast, significantly less lipolysis was noted using the automated device. In vivo fat volume retention was significantly greater than with the modified Coleman technique at 4, 6, 8, and 12 week time points. This corresponded with significantly greater histological scores for healthy fat and lower scores for injury following injection with the device. Conclusions Biological properties of injected tissues reflect how disruptive and harmful techniques for placement of fat may be, and our in vitro and in vivo data both support the use of the automated, low shear devices compared to the modified Coleman technique. PMID:24622574

  5. Exploiting the Lab-on-Valve Concept for Determination of Trace Levels of Metals in Complex Matrices with Detection by ETAAS and ICPMS

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Wang, Jianhua

    approach [1,2]. Coupled to detection by ETAAS and ICPMS, and illustrated by recent exploits in the authors’ laboratory, it is shown that this methodology eliminates the problems encountered in conventional on-line column preconcentration systems and at the same time improves the overall operational......Termed the third generation of flow injection analysis, the Sequential Injection (SI)-Lab-on-Valve (LOV) concept has proven to entail specific advantages and to allow novel and unique applications. Both in term of its use in the automation and micro-miniaturization of suitable on-line sample...

  6. Use of an automated bolus calculator in MDI-treated type 1 diabetes

    DEFF Research Database (Denmark)

    Schmidt, Signe; Meldgaard, Merete; Serifovski, Nermin

    2012-01-01

    To investigate the effect of flexible intensive insulin therapy (FIIT) and an automated bolus calculator (ABC) in a Danish type 1 diabetes population treated with multiple daily injections. Furthermore, to test the feasibility of teaching FIIT in a 3-h structured course....

  7. Multi-agent sequential hypothesis testing

    KAUST Repository

    Kim, Kwang-Ki K.; Shamma, Jeff S.

    2014-01-01

    incorporate costs of taking private/public measurements, costs of time-difference and disagreement in actions of agents, and costs of false declaration/choices in the sequential hypothesis testing. The corresponding sequential decision processes have well

  8. Assessment of automated disease detection in diabetic retinopathy screening using two-field photography.

    Science.gov (United States)

    Goatman, Keith; Charnley, Amanda; Webster, Laura; Nussey, Stephen

    2011-01-01

    To assess the performance of automated disease detection in diabetic retinopathy screening using two field mydriatic photography. Images from 8,271 sequential patient screening episodes from a South London diabetic retinopathy screening service were processed by the Medalytix iGrading™ automated grading system. For each screening episode macular-centred and disc-centred images of both eyes were acquired and independently graded according to the English national grading scheme. Where discrepancies were found between the automated result and original manual grade, internal and external arbitration was used to determine the final study grades. Two versions of the software were used: one that detected microaneurysms alone, and one that detected blot haemorrhages and exudates in addition to microaneurysms. Results for each version were calculated once using both fields and once using the macula-centred field alone. Of the 8,271 episodes, 346 (4.2%) were considered unassessable. Referable disease was detected in 587 episodes (7.1%). The sensitivity of the automated system for detecting unassessable images ranged from 97.4% to 99.1% depending on configuration. The sensitivity of the automated system for referable episodes ranged from 98.3% to 99.3%. All the episodes that included proliferative or pre-proliferative retinopathy were detected by the automated system regardless of configuration (192/192, 95% confidence interval 98.0% to 100%). If implemented as the first step in grading, the automated system would have reduced the manual grading effort by between 2,183 and 3,147 patient episodes (26.4% to 38.1%). Automated grading can safely reduce the workload of manual grading using two field, mydriatic photography in a routine screening service.

  9. Tolerance and biochemical effects from intravenous injection of ioxaglate in healthy volunteers

    International Nuclear Information System (INIS)

    Nilsson, P.E.; Aspelin, P.; Nyman, U.; Hedner, U.; Malmoe Allmaenna Sjukhus

    1984-01-01

    The influence of intravenous injection of ioxaglate (Hexabrix, 320 mg I/ml) on various biochemical, coagulation and fibrinolytic parameters, fractionated plasma proteins, precordial ECG and blood pressure was prospectively and sequentially studied in 9 healthy volunteers. One ml/kg body weight of the contrast medium was injected within one minute into an antecubital vein. Small, but statistically significant, changes in some of the biochemical parameters were found during the observation period, 2 to 4 days. All values of the biochemical parameters were, however, within the normal reference range for each parameter. No significant alterations were seen in the coagulation parameters. Increased fibrinolysis was recorded in some subjects both before and after the injection. No fibrinolytic degradation products were found indicating that the fibrinolysis was nominal. No significant changes were observed in the fractionated plasma proteins. The heart rate decreased significantly 15 seconds after commencing the injection. No significant changes in blood pressure were recorded. Two participants became nauseated and one of them vomited during the injection. Apart from this, no adverse effects were noted. No clinically significant changes following the injections were found. (orig.)

  10. Sequential stochastic optimization

    CERN Document Server

    Cairoli, Renzo

    1996-01-01

    Sequential Stochastic Optimization provides mathematicians and applied researchers with a well-developed framework in which stochastic optimization problems can be formulated and solved. Offering much material that is either new or has never before appeared in book form, it lucidly presents a unified theory of optimal stopping and optimal sequential control of stochastic processes. This book has been carefully organized so that little prior knowledge of the subject is assumed; its only prerequisites are a standard graduate course in probability theory and some familiarity with discrete-paramet

  11. An Automated Mouse Tail Vascular Access System by Vision and Pressure Feedback.

    Science.gov (United States)

    Chang, Yen-Chi; Berry-Pusey, Brittany; Yasin, Rashid; Vu, Nam; Maraglia, Brandon; Chatziioannou, Arion X; Tsao, Tsu-Chin

    2015-08-01

    This paper develops an automated vascular access system (A-VAS) with novel vision-based vein and needle detection methods and real-time pressure feedback for murine drug delivery. Mouse tail vein injection is a routine but critical step for preclinical imaging applications. Due to the small vein diameter and external disturbances such as tail hair, pigmentation, and scales, identifying vein location is difficult and manual injections usually result in poor repeatability. To improve the injection accuracy, consistency, safety, and processing time, A-VAS was developed to overcome difficulties in vein detection noise rejection, robustness in needle tracking, and visual servoing integration with the mechatronics system.

  12. Automated cellular sample preparation using a Centrifuge-on-a-Chip.

    Science.gov (United States)

    Mach, Albert J; Kim, Jae Hyun; Arshi, Armin; Hur, Soojung Claire; Di Carlo, Dino

    2011-09-07

    The standard centrifuge is a laboratory instrument widely used by biologists and medical technicians for preparing cell samples. Efforts to automate the operations of concentration, cell separation, and solution exchange that a centrifuge performs in a simpler and smaller platform have had limited success. Here, we present a microfluidic chip that replicates the functions of a centrifuge without moving parts or external forces. The device operates using a purely fluid dynamic phenomenon in which cells selectively enter and are maintained in microscale vortices. Continuous and sequential operation allows enrichment of cancer cells from spiked blood samples at the mL min(-1) scale, followed by fluorescent labeling of intra- and extra-cellular antigens on the cells without the need for manual pipetting and washing steps. A versatile centrifuge-analogue may open opportunities in automated, low-cost and high-throughput sample preparation as an alternative to the standard benchtop centrifuge in standardized clinical diagnostics or resource poor settings.

  13. Exploring the sequential lineup advantage using WITNESS.

    Science.gov (United States)

    Goodsell, Charles A; Gronlund, Scott D; Carlson, Curt A

    2010-12-01

    Advocates claim that the sequential lineup is an improvement over simultaneous lineup procedures, but no formal (quantitatively specified) explanation exists for why it is better. The computational model WITNESS (Clark, Appl Cogn Psychol 17:629-654, 2003) was used to develop theoretical explanations for the sequential lineup advantage. In its current form, WITNESS produced a sequential advantage only by pairing conservative sequential choosing with liberal simultaneous choosing. However, this combination failed to approximate four extant experiments that exhibited large sequential advantages. Two of these experiments became the focus of our efforts because the data were uncontaminated by likely suspect position effects. Decision-based and memory-based modifications to WITNESS approximated the data and produced a sequential advantage. The next step is to evaluate the proposed explanations and modify public policy recommendations accordingly.

  14. Sequential and simultaneous choices: testing the diet selection and sequential choice models.

    Science.gov (United States)

    Freidin, Esteban; Aw, Justine; Kacelnik, Alex

    2009-03-01

    We investigate simultaneous and sequential choices in starlings, using Charnov's Diet Choice Model (DCM) and Shapiro, Siller and Kacelnik's Sequential Choice Model (SCM) to integrate function and mechanism. During a training phase, starlings encountered one food-related option per trial (A, B or R) in random sequence and with equal probability. A and B delivered food rewards after programmed delays (shorter for A), while R ('rejection') moved directly to the next trial without reward. In this phase we measured latencies to respond. In a later, choice, phase, birds encountered the pairs A-B, A-R and B-R, the first implementing a simultaneous choice and the second and third sequential choices. The DCM predicts when R should be chosen to maximize intake rate, and SCM uses latencies of the training phase to predict choices between any pair of options in the choice phase. The predictions of both models coincided, and both successfully predicted the birds' preferences. The DCM does not deal with partial preferences, while the SCM does, and experimental results were strongly correlated to this model's predictions. We believe that the SCM may expose a very general mechanism of animal choice, and that its wider domain of success reflects the greater ecological significance of sequential over simultaneous choices.

  15. Automated evaluation of the effect of ionic liquids on catalase activity.

    Science.gov (United States)

    Pinto, Paula C A G; Costa, Andreia D F; Lima, José L F C; Saraiva, M Lúcia M F S

    2011-03-01

    An automated assay for the evaluation of the influence of ionic liquids on the activity of catalase was developed. The activity and inhibition assays were implemented in a sequential injection analysis (SIA) system and intended to contribute for the estimation of the toxicity of the tested compounds. The fast developed methodology was based on the oxidation of the non-fluorescent probe amplex red, in the presence of H₂O₂, to produce resorufin, a strong fluorescent compound. Catalase activity was monitored by the decreased of the fluorescence intensity due to the consumption of H₂O₂ by the enzyme. The activity assays were performed in strictly aqueous media and in the presence of increasing concentrations of seven commercially available ionic liquids and sodium azide, a strong inhibitor of catalase. IC₅₀ values between 0.15 and 2.77 M were obtained for the tested compounds, revealing distinct inhibitory effects. This allowed us to perform some considerations about the toxicity of the tested cations and anions. The developed SIA methodology showed to be robust and exhibited good repeatability in all the assay conditions. On the other hand, it proved to be in good agreement with the actual concerns of "Green Chemistry" since it involved the consumption of less than 200 μL of reagents and the production of only 1.7 mL of effluent (per cycle) and at the same time reduced the operator exposure resulting in increased environmental and human safety. Copyright © 2010. Published by Elsevier Ltd.

  16. Sequential memory: Binding dynamics

    Science.gov (United States)

    Afraimovich, Valentin; Gong, Xue; Rabinovich, Mikhail

    2015-10-01

    Temporal order memories are critical for everyday animal and human functioning. Experiments and our own experience show that the binding or association of various features of an event together and the maintaining of multimodality events in sequential order are the key components of any sequential memories—episodic, semantic, working, etc. We study a robustness of binding sequential dynamics based on our previously introduced model in the form of generalized Lotka-Volterra equations. In the phase space of the model, there exists a multi-dimensional binding heteroclinic network consisting of saddle equilibrium points and heteroclinic trajectories joining them. We prove here the robustness of the binding sequential dynamics, i.e., the feasibility phenomenon for coupled heteroclinic networks: for each collection of successive heteroclinic trajectories inside the unified networks, there is an open set of initial points such that the trajectory going through each of them follows the prescribed collection staying in a small neighborhood of it. We show also that the symbolic complexity function of the system restricted to this neighborhood is a polynomial of degree L - 1, where L is the number of modalities.

  17. Fusion Energy Division automation of the ISX-B neutral beams

    International Nuclear Information System (INIS)

    Bates, S.C.; Hanna, P.C.

    1982-06-01

    Operation of the two neutral beams on the ISX-B tokamak has been fully automated for an injected power up to 2 MW. A PDP 11/34 FORTRAN program conditions and injects the beams using commercial CAMAC hardware and ad hoc modifications of the beam controls. The fundamental beam conditioning algorithm is based on the breakdown history of the source. Difficulties encountered were noise entering the CAMAC system through control and data lines and the lack of well-defined operating heuristics detailed problem diagnostic techniques. A brief description is given of the hardware and software systems, operating techniques, and items of special concern

  18. Effects of Injection Rate Profile on Combustion Process and Emissions in a Diesel Engine

    Directory of Open Access Journals (Sweden)

    Fuqiang Bai

    2017-01-01

    Full Text Available When multi-injection is implemented in diesel engine via high pressure common rail injection system, changed interval between injection pulses can induce variation of injection rate profile for sequential injection pulse, though other control parameters are the same. Variations of injection rate shape which influence the air-fuel mixing and combustion process will be important for designing injection strategy. In this research, CFD numerical simulations using KIVA-3V were conducted for examining the effects of injection rate shape on diesel combustion and emissions. After the model was validated by experimental results, five different shapes (including rectangle, slope, triangle, trapezoid, and wedge of injection rate profiles were investigated. Modeling results demonstrate that injection rate shape can have obvious influence on heat release process and heat release traces which cause different combustion process and emissions. It is observed that the baseline, rectangle (flat, shape of injection rate can have better balance between NOx and soot emissions than the other investigated shapes. As wedge shape brings about the lowest NOx emissions due to retarded heat release, it produces the highest soot emissions among the five shapes. Trapezoid shape has the lowest soot emissions, while its NOx is not the highest one. The highest NOx emissions were produced by triangle shape due to higher peak injection rate.

  19. Comparison of simultaneous and sequential administration of fentanyl-propofol for surgical abortion: a randomized single-blinded controlled trial.

    Science.gov (United States)

    Gao, Wei; Sha, Baoyong; Zhao, Yuan; Fan, Zhe; Liu, Lin; Shen, Xin

    2017-08-01

    Propofol lipid emulsion (PLE) is a nanosized sedative, and it is used with a combination of salted antalgic prodrug, fentanyl citrate (FC). To illustrate the synergistic effect of mixing, we compared the sedation/analgesia resulting from simultaneous and sequential administration in surgically induced abortion (No. ChiCTR-IPC-15006153). Simultaneous group showed lower bispectral index, blood pressure, and heart rate, when cannula was inserted into the uterus. It also showed less frequency of hypertension, sinus tachycardia, movement, pain at the injection site, and additional FC. Therefore, premixing of PLE and FC enhanced the sedation and analgesia; stabilized the hemodynamics; lessened the incidence of movement and injection pain; and reduced the requirement of drugs.

  20. Sequential Probability Ration Tests : Conservative and Robust

    NARCIS (Netherlands)

    Kleijnen, J.P.C.; Shi, Wen

    2017-01-01

    In practice, most computers generate simulation outputs sequentially, so it is attractive to analyze these outputs through sequential statistical methods such as sequential probability ratio tests (SPRTs). We investigate several SPRTs for choosing between two hypothesized values for the mean output

  1. Automated dual-wavelength spectrophotometer optimized for phytochrome assay

    International Nuclear Information System (INIS)

    Pratt, L.H.; Wampler, J.E.; Rich, E.S. Jr.

    1985-01-01

    A microcomputer-controlled dual-wavelength spectrophotometer suitable for automated phytochrome assay is described. The optomechanical unit provides for sequential irradiation of the sample by the two measuring wavelengths with intervening dark intervals and for actinic irradiation to interconvert phytochrome between its two forms. Photomultiplier current is amplified, converted to a digital value and transferred into the computer using a custom-designed IEEE-488 bus interface. The microcomputer calculates mathematically both absorbance and absorbance difference values with dynamic correction for photomultiplier dark current. In addition, the computer controls the operating parameters of the spectrophotometer via a separate interface. These parameters include control of the durations of measuring and actinic irradiation intervals and their sequence. 14 references, 4 figures

  2. Sequential lineup presentation: Patterns and policy

    OpenAIRE

    Lindsay, R C L; Mansour, Jamal K; Beaudry, J L; Leach, A-M; Bertrand, M I

    2009-01-01

    Sequential lineups were offered as an alternative to the traditional simultaneous lineup. Sequential lineups reduce incorrect lineup selections; however, the accompanying loss of correct identifications has resulted in controversy regarding adoption of the technique. We discuss the procedure and research relevant to (1) the pattern of results found using sequential versus simultaneous lineups; (2) reasons (theory) for differences in witness responses; (3) two methodological issues; and (4) im...

  3. Sequential Product of Quantum Effects: An Overview

    Science.gov (United States)

    Gudder, Stan

    2010-12-01

    This article presents an overview for the theory of sequential products of quantum effects. We first summarize some of the highlights of this relatively recent field of investigation and then provide some new results. We begin by discussing sequential effect algebras which are effect algebras endowed with a sequential product satisfying certain basic conditions. We then consider sequential products of (discrete) quantum measurements. We next treat transition effect matrices (TEMs) and their associated sequential product. A TEM is a matrix whose entries are effects and whose rows form quantum measurements. We show that TEMs can be employed for the study of quantum Markov chains. Finally, we prove some new results concerning TEMs and vector densities.

  4. Optimal Sequential Rules for Computer-Based Instruction.

    Science.gov (United States)

    Vos, Hans J.

    1998-01-01

    Formulates sequential rules for adapting the appropriate amount of instruction to learning needs in the context of computer-based instruction. Topics include Bayesian decision theory, threshold and linear-utility structure, psychometric model, optimal sequential number of test questions, and an empirical example of sequential instructional…

  5. Automated segmentation and reconstruction of patient-specific cardiac anatomy and pathology from in vivo MRI

    International Nuclear Information System (INIS)

    Ringenberg, Jordan; Deo, Makarand; Devabhaktuni, Vijay; Filgueiras-Rama, David; Pizarro, Gonzalo; Ibañez, Borja; Berenfeld, Omer; Boyers, Pamela; Gold, Jeffrey

    2012-01-01

    This paper presents an automated method to segment left ventricle (LV) tissues from functional and delayed-enhancement (DE) cardiac magnetic resonance imaging (MRI) scans using a sequential multi-step approach. First, a region of interest (ROI) is computed to create a subvolume around the LV using morphological operations and image arithmetic. From the subvolume, the myocardial contours are automatically delineated using difference of Gaussians (DoG) filters and GSV snakes. These contours are used as a mask to identify pathological tissues, such as fibrosis or scar, within the DE-MRI. The presented automated technique is able to accurately delineate the myocardium and identify the pathological tissue in patient sets. The results were validated by two expert cardiologists, and in one set the automated results are quantitatively and qualitatively compared with expert manual delineation. Furthermore, the method is patient-specific, performed on an entire patient MRI series. Thus, in addition to providing a quick analysis of individual MRI scans, the fully automated segmentation method is used for effectively tagging regions in order to reconstruct computerized patient-specific 3D cardiac models. These models can then be used in electrophysiological studies and surgical strategy planning. (paper)

  6. Quantum Inequalities and Sequential Measurements

    International Nuclear Information System (INIS)

    Candelpergher, B.; Grandouz, T.; Rubinx, J.L.

    2011-01-01

    In this article, the peculiar context of sequential measurements is chosen in order to analyze the quantum specificity in the two most famous examples of Heisenberg and Bell inequalities: Results are found at some interesting variance with customary textbook materials, where the context of initial state re-initialization is described. A key-point of the analysis is the possibility of defining Joint Probability Distributions for sequential random variables associated to quantum operators. Within the sequential context, it is shown that Joint Probability Distributions can be defined in situations where not all of the quantum operators (corresponding to random variables) do commute two by two. (authors)

  7. Automated location detection of injection site for preclinical stereotactic neurosurgery procedure

    Science.gov (United States)

    Abbaszadeh, Shiva; Wu, Hemmings C. H.

    2017-03-01

    Currently, during stereotactic neurosurgery procedures, the manual task of locating the proper area for needle insertion or implantation of electrode/cannula/optic fiber can be time consuming. The requirement of the task is to quickly and accurately find the location for insertion. In this study we investigate an automated method to locate the entry point of region of interest. This method leverages a digital image capture system, pattern recognition, and motorized stages. Template matching of known anatomical identifiable regions is used to find regions of interest (e.g. Bregma) in rodents. For our initial study, we tackle the problem of automatically detecting the entry point.

  8. Semi-automated digital image analysis of patellofemoral joint space width from lateral knee radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Grochowski, S.J. [Mayo Clinic, Department of Orthopedic Surgery, Rochester (United States); Amrami, K.K. [Mayo Clinic, Department of Radiology, Rochester (United States); Kaufman, K. [Mayo Clinic, Department of Orthopedic Surgery, Rochester (United States); Mayo Clinic/Foundation, Biomechanics Laboratory, Department of Orthopedic Surgery, Charlton North L-110L, Rochester (United States)

    2005-10-01

    To design a semi-automated program to measure minimum patellofemoral joint space width (JSW) using standing lateral view radiographs. Lateral patellofemoral knee radiographs were obtained from 35 asymptomatic subjects. The radiographs were analyzed to report both the repeatability of the image analysis program and the reproducibility of JSW measurements within a 2 week period. The results were also compared with manual measurements done by an experienced musculoskeletal radiologist. The image analysis program was shown to have an excellent coefficient of repeatability of 0.18 and 0.23 mm for intra- and inter-observer measurements respectively. The manual method measured a greater minimum JSW than the automated method. Reproducibility between days was comparable to other published results, but was less satisfactory for both manual and semi-automated measurements. The image analysis program had an inter-day coefficient of repeatability of 1.24 mm, which was lower than 1.66 mm for the manual method. A repeatable semi-automated method for measurement of the patellofemoral JSW from radiographs has been developed. The method is more accurate than manual measurements. However, the between-day reproducibility is higher than the intra-day reproducibility. Further investigation of the protocol for obtaining sequential lateral knee radiographs is needed in order to reduce the between-day variability. (orig.)

  9. Using phylogenetic analysis to trace HIV-1 migration among western European injecting drug users seroconverting from 1984 to 1997

    NARCIS (Netherlands)

    Op de Coul, E. L.; Prins, M. [= Maria; Cornelissen, M.; van der Schoot, A.; Boufassa, F.; Brettle, R. P.; Hernández-Aguado, L.; Schiffer, V.; McMenamin, J.; Rezza, G.; Robertson, R.; Zangerle, R.; Goudsmit, J.; Coutinho, R. A.; Lukashov, V. V.

    2001-01-01

    OBJECTIVE: To reconstruct the epidemiological relationships of the HIV epidemics among injecting drug users (IDU) in western Europe. METHODS: HIV env V3 sequences of and epidemiological data were obtained from 145 IDU who seroconverted in three sequential periods: 1984-1988, 1989-1992 and 1993-1997.

  10. Sequential Generalized Transforms on Function Space

    Directory of Open Access Journals (Sweden)

    Jae Gil Choi

    2013-01-01

    Full Text Available We define two sequential transforms on a function space Ca,b[0,T] induced by generalized Brownian motion process. We then establish the existence of the sequential transforms for functionals in a Banach algebra of functionals on Ca,b[0,T]. We also establish that any one of these transforms acts like an inverse transform of the other transform. Finally, we give some remarks about certain relations between our sequential transforms and other well-known transforms on Ca,b[0,T].

  11. Forced Sequence Sequential Decoding

    DEFF Research Database (Denmark)

    Jensen, Ole Riis; Paaske, Erik

    1998-01-01

    We describe a new concatenated decoding scheme based on iterations between an inner sequentially decoded convolutional code of rate R=1/4 and memory M=23, and block interleaved outer Reed-Solomon (RS) codes with nonuniform profile. With this scheme decoding with good performance is possible as low...... as Eb/N0=0.6 dB, which is about 1.25 dB below the signal-to-noise ratio (SNR) that marks the cutoff rate for the full system. Accounting for about 0.45 dB due to the outer codes, sequential decoding takes place at about 1.7 dB below the SNR cutoff rate for the convolutional code. This is possible since...... the iteration process provides the sequential decoders with side information that allows a smaller average load and minimizes the probability of computational overflow. Analytical results for the probability that the first RS word is decoded after C computations are presented. These results are supported...

  12. Manual or automated measuring of antipsychotics' chemical oxygen demand.

    Science.gov (United States)

    Pereira, Sarah A P; Costa, Susana P F; Cunha, Edite; Passos, Marieta L C; Araújo, André R S T; Saraiva, M Lúcia M F S

    2018-05-15

    Antipsychotic (AP) drugs are becoming accumulated in terrestrial and aqueous resources due to their actual consumption. Thus, the search of methods for assessing the contamination load of these drugs is mandatory. The COD is a key parameter used for monitoring water quality upon the assessment of the effect of polluting agents on the oxygen level. Thus, the present work aims to assess the chemical oxygen demand (COD) levels of several typical and atypical antipsychotic drugs in order to obtain structure-activity relationships. It was implemented the titrimetric method with potassium dichromate as oxidant and a digestion step of 2h, followed by the measurement of remained unreduced dichromate by titration. After that, an automated sequential injection analysis (SIA) method was, also, used aiming to overcome some drawbacks of the titrimetric method. The results obtained showed a relationship between the chemical structures of antipsychotic drugs and their COD values, where the presence of aromatic rings and oxidable groups give higher COD values. It was obtained a good compliance between the results of the reference batch procedure and the SIA system, and the APs were clustered in two groups, with the values ratio between the methodologies, of 2 or 4, in the case of lower or higher COD values, respectively. The SIA methodology is capable of operating as a screening method, in any stage of a synthetic process, being also more environmentally friendly, and cost-effective. Besides, the studies presented open promising perspectives for the improvement of the effectiveness of pharmaceutical removal from the waste effluents, by assessing COD values. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Sequential probability ratio controllers for safeguards radiation monitors

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Coop, K.L.; Nixon, K.V.

    1984-01-01

    Sequential hypothesis tests applied to nuclear safeguards accounting methods make the methods more sensitive to detecting diversion. The sequential tests also improve transient signal detection in safeguards radiation monitors. This paper describes three microprocessor control units with sequential probability-ratio tests for detecting transient increases in radiation intensity. The control units are designed for three specific applications: low-intensity monitoring with Poisson probability ratios, higher intensity gamma-ray monitoring where fixed counting intervals are shortened by sequential testing, and monitoring moving traffic where the sequential technique responds to variable-duration signals. The fixed-interval controller shortens a customary 50-s monitoring time to an average of 18 s, making the monitoring delay less bothersome. The controller for monitoring moving vehicles benefits from the sequential technique by maintaining more than half its sensitivity when the normal passage speed doubles

  14. Determination of the total acidity in soft drinks using potentiometric sequential injection titration.

    Science.gov (United States)

    van Staden, J Koos F; Mashamba, M Mulalo G; Stefan, R Raluca I

    2002-12-06

    A potentiometric SI titration system for the determination of total acidity in soft drinks is proposed. The concept is based on the aspiration of the acid soft drink sample between two base zones into a holding coil with the volume of the first base zone twice to that of the second one and channelled by flow reversal through a reaction coil to a potentiometric sensor. A solution of 0.1 mol l(-1) sodium chloride is used as ionic strength adjustment buffer in the carrier stream. The system has been applied to the analysis of some South African soft drinks having a total acidity level of about 0.2-0.3% (w/v). The method has a sample frequency of 45 samples per h with a linear range of 0.1 and 0.6% (w/v). It is easy to use, fully computerised, and gives the results that are comparable to both automated batch titration and manual titration.

  15. A new rat model of portal hypertension induced by intraportal injection of microspheres

    Science.gov (United States)

    Li, Xiang-Nong; Benjamin, IS; Alexander, B

    1998-01-01

    AIM: To produce a new rat model of portal hypertension by intraportal injection of microspheres. METHODS: Measured aliquots of single or different-sized microspheres (15, 40, 80μm) were injected into the portal vein to block intrahepatic portal radicals. The resultant changes in arterial,portal,hepatic venous and splenic pulp pressures were monitored. The liver and lungs were excised for histological examination. RESULTS: Portal venous pressure was elevated from basal value of 0.89-1.02 kPa to a steady-state of 1.98-3.19 kPa following the sequential injections of single- or different-sized microspheres, with a markedly lowered mean arterial pressure. However, a small-dose injection of 80 μm microspheres (1.8 × 105) produced a steady-state portal venous pressure of 2.53 × 0.17 kPa, and all rats showed normal arterial pressures. In addition, numerous microspheres were found in the lungs in all experimental groups. CONCLUSION: Portal hypertension can be reproduced in rats by intraportal injection of microspheres at a small dose of 80 μm (1.8 × 105). Intrahepatic portal-systemic shunts probably exist in the normal rat liver. PMID:11819236

  16. An automated flow injection system for metal determination by flame atomic absorption spectrometry involving on-line fabric disk sorptive extraction technique.

    Science.gov (United States)

    Anthemidis, A; Kazantzi, V; Samanidou, V; Kabir, A; Furton, K G

    2016-08-15

    A novel flow injection-fabric disk sorptive extraction (FI-FDSE) system was developed for automated determination of trace metals. The platform was based on a minicolumn packed with sol-gel coated fabric media in the form of disks, incorporated into an on-line solid-phase extraction system, coupled with flame atomic absorption spectrometry (FAAS). This configuration provides minor backpressure, resulting in high loading flow rates and shorter analytical cycles. The potentials of this technique were demonstrated for trace lead and cadmium determination in environmental water samples. The applicability of different sol-gel coated FPSE media was investigated. The on-line formed complex of metal with ammonium pyrrolidine dithiocarbamate (APDC) was retained onto the fabric surface and methyl isobutyl ketone (MIBK) was used to elute the analytes prior to atomization. For 90s preconcentration time, enrichment factors of 140 and 38 and detection limits (3σ) of 1.8 and 0.4μgL(-1) were achieved for lead and cadmium determination, respectively, with a sampling frequency of 30h(-1). The accuracy of the proposed method was estimated by analyzing standard reference materials and spiked water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Biased lineups: sequential presentation reduces the problem.

    Science.gov (United States)

    Lindsay, R C; Lea, J A; Nosworthy, G J; Fulford, J A; Hector, J; LeVan, V; Seabrook, C

    1991-12-01

    Biased lineups have been shown to increase significantly false, but not correct, identification rates (Lindsay, Wallbridge, & Drennan, 1987; Lindsay & Wells, 1980; Malpass & Devine, 1981). Lindsay and Wells (1985) found that sequential lineup presentation reduced false identification rates, presumably by reducing reliance on relative judgment processes. Five staged-crime experiments were conducted to examine the effect of lineup biases and sequential presentation on eyewitness recognition accuracy. Sequential lineup presentation significantly reduced false identification rates from fair lineups as well as from lineups biased with regard to foil similarity, instructions, or witness attire, and from lineups biased in all of these ways. The results support recommendations that police present lineups sequentially.

  18. Determination of drugs in biological fluids by direct injection of samples for liquid-chromatographic analysis.

    Science.gov (United States)

    Mullett, Wayne M

    2007-03-10

    The analysis of drugs in various biological fluids is an important criterion for the determination of the physiological performance of a drug. After sampling of the biological fluid, the next step in the analytical process is sample preparation. The complexity of biological fluids adds to the challenge of direct determination of the drug by chromatographic analysis, therefore demanding a sample preparation step that is often time-consuming, tedious, and frequently overlooked. However, direct on-line injection methods offer the advantage of reducing sample preparation steps and enabling effective pre-concentration and clean-up of biological fluids. These procedures can be automated and therefore reduce the requirements for handling potentially infectious biomaterial, improve reproducibility, and minimize sample manipulations and potential contamination. The objective of this review is to present an overview of the existing literature with emphasis on advances in automated sample preparation methods for liquid-chromatographic methods. More specifically, this review concentrates on the use of direct injection techniques, such as restricted-access materials, turbulent-flow chromatography and other automated on-line solid-phase extraction (SPE) procedures. It also includes short overviews of emerging automated extraction-phase technologies, such as molecularly imprinted polymers, in-tube solid-phase micro-extraction, and micro-extraction in a packed syringe for a more selective extraction of analytes from complex samples, providing further improvements in the analysis of biological materials. Lastly, the outlook for these methods and potential new applications for these technologies are briefly discussed.

  19. Lineup composition, suspect position, and the sequential lineup advantage.

    Science.gov (United States)

    Carlson, Curt A; Gronlund, Scott D; Clark, Steven E

    2008-06-01

    N. M. Steblay, J. Dysart, S. Fulero, and R. C. L. Lindsay (2001) argued that sequential lineups reduce the likelihood of mistaken eyewitness identification. Experiment 1 replicated the design of R. C. L. Lindsay and G. L. Wells (1985), the first study to show the sequential lineup advantage. However, the innocent suspect was chosen at a lower rate in the simultaneous lineup, and no sequential lineup advantage was found. This led the authors to hypothesize that protection from a sequential lineup might emerge only when an innocent suspect stands out from the other lineup members. In Experiment 2, participants viewed a simultaneous or sequential lineup with either the guilty suspect or 1 of 3 innocent suspects. Lineup fairness was varied to influence the degree to which a suspect stood out. A sequential lineup advantage was found only for the unfair lineups. Additional analyses of suspect position in the sequential lineups showed an increase in the diagnosticity of suspect identifications as the suspect was placed later in the sequential lineup. These results suggest that the sequential lineup advantage is dependent on lineup composition and suspect position. (c) 2008 APA, all rights reserved

  20. Automated Purification and Suspension Array Detection of 16S rRNA from Soil and Sediment Extracts by Using Tunable Surface Microparticles

    OpenAIRE

    Chandler, Darrell P.; Jarrell, Ann E.

    2004-01-01

    Autonomous, field-deployable molecular detection systems require seamless integration of complex biochemical solutions and physical or mechanical processing steps. In an attempt to simplify the fluidic requirements for integrated biodetection systems, we used tunable surface microparticles both as an rRNA affinity purification resin in a renewable microcolumn sample preparation system and as the sensor surface in a flow cytometer detector. The tunable surface detection limits in both low- and...

  1. Microbially Enhanced Oil Recovery by Sequential Injection of Light Hydrocarbon and Nitrate in Low- And High-Pressure Bioreactors.

    Science.gov (United States)

    Gassara, Fatma; Suri, Navreet; Stanislav, Paul; Voordouw, Gerrit

    2015-10-20

    Microbially enhanced oil recovery (MEOR) often involves injection of aqueous molasses and nitrate to stimulate resident or introduced bacteria. Use of light oil components like toluene, as electron donor for nitrate-reducing bacteria (NRB), offers advantages but at 1-2 mM toluene is limiting in many heavy oils. Because addition of toluene to the oil increased reduction of nitrate by NRB, we propose an MEOR technology, in which water amended with light hydrocarbon below the solubility limit (5.6 mM for toluene) is injected to improve the nitrate reduction capacity of the oil along the water flow path, followed by injection of nitrate, other nutrients (e.g., phosphate) and a consortium of NRB, if necessary. Hydrocarbon- and nitrate-mediated MEOR was tested in low- and high-pressure, water-wet sandpack bioreactors with 0.5 pore volumes of residual oil in place (ROIP). Compared to control bioreactors, those with 11-12 mM of toluene in the oil (gained by direct addition or by aqueous injection) and 80 mM of nitrate in the aqueous phase produced 16.5 ± 4.4% of additional ROIP (N = 10). Because toluene is a cheap commodity chemical, HN-MEOR has the potential to be a cost-effective method for additional oil production even in the current low oil price environment.

  2. The principles of designing autoregulated circuits of particles injection in synchrotron accelerators

    International Nuclear Information System (INIS)

    Karabekov, I.P.; Krol', V.K.

    1974-01-01

    The paper deals with an investigation of beam injection systems of large electron synchrotrons from the point of view of a possibility of the injection process automation. The injection system elements of the Erevan synchrotron are considered as an example to show the possibility of designing a closed automatic control system based on the beam parameter data. To obtain data on the beam parameters a scheme based on magnetoinduction zero-indicators is used. The particle capture int orbit and automatic control system is shown to be indeterminate without preliminary monochromatization of the beam. The automatic control functional scheme is presented and main technical requirements for some synchrotron components are formulated. The realization of the proposed automatic control system on the Erevan synchrotron will ensure the matching of beam trajectory parameters at the point of particle capture into orbit with injected particle energy and the injection field value on the orbit, if the accuracy required for the adjustment of the magnetic field parameters necessary for the first turns is achieved

  3. Tradable permit allocations and sequential choice

    Energy Technology Data Exchange (ETDEWEB)

    MacKenzie, Ian A. [Centre for Economic Research, ETH Zuerich, Zurichbergstrasse 18, 8092 Zuerich (Switzerland)

    2011-01-15

    This paper investigates initial allocation choices in an international tradable pollution permit market. For two sovereign governments, we compare allocation choices that are either simultaneously or sequentially announced. We show sequential allocation announcements result in higher (lower) aggregate emissions when announcements are strategic substitutes (complements). Whether allocation announcements are strategic substitutes or complements depends on the relationship between the follower's damage function and governments' abatement costs. When the marginal damage function is relatively steep (flat), allocation announcements are strategic substitutes (complements). For quadratic abatement costs and damages, sequential announcements provide a higher level of aggregate emissions. (author)

  4. Pore network quantification of sandstones under experimental CO2 injection using image analysis

    Science.gov (United States)

    Berrezueta, Edgar; González-Menéndez, Luís; Ordóñez-Casado, Berta; Olaya, Peter

    2015-04-01

    Automated-image identification and quantification of minerals, pores and textures together with petrographic analysis can be applied to improve pore system characterization in sedimentary rocks. Our case study is focused on the application of these techniques to study the evolution of rock pore network subjected to super critical CO2-injection. We have proposed a Digital Image Analysis (DIA) protocol that guarantees measurement reproducibility and reliability. This can be summarized in the following stages: (i) detailed description of mineralogy and texture (before and after CO2-injection) by optical and scanning electron microscopy (SEM) techniques using thin sections; (ii) adjustment and calibration of DIA tools; (iii) data acquisition protocol based on image capture with different polarization conditions (synchronized movement of polarizers); (iv) study and quantification by DIA that allow (a) identification and isolation of pixels that belong to the same category: minerals vs. pores in each sample and (b) measurement of changes in pore network, after the samples have been exposed to new conditions (in our case: SC-CO2-injection). Finally, interpretation of the petrography and the measured data by an automated approach were done. In our applied study, the DIA results highlight the changes observed by SEM and microscopic techniques, which consisted in a porosity increase when CO2 treatment occurs. Other additional changes were minor: variations in the roughness and roundness of pore edges, and pore aspect ratio, shown in the bigger pore population. Additionally, statistic tests of pore parameters measured were applied to verify that the differences observed between samples before and after CO2-injection were significant.

  5. Behaviour of venous flow rates in intermittent sequential pneumatic compression of the legs using different compression strengths

    International Nuclear Information System (INIS)

    Fassmann-Glaser, I.

    1984-01-01

    A study with 25 patients was performed in order to find out whether intermittent, sequential, pneumatic leg compression is of value in the preventive management of thrombosis due to its effect on the venous flow rates. For this purpose, xenon 133 was injected into one of the foot veins and the flow rate in each case determined for the distance between instep and inguen using different compression strengths, with pressure being exerted on the ankle, calf and thigh. Increased flow rates were already measured at an average pressure value of 34.5 mmHg, while the maximum effect was achieved by exerting a pressure of 92.5 mmHg, which increased the flow rate by 366% as compared to the baseline value. The results point to a significant improvement of the venous flow rates due to intermittent, sequential, pneumatic leg compression and thus provide evidence to prove the value of this method in the prevention of hemostasis and thrombosis. (TRV) [de

  6. Applying the minimax principle to sequential mastery testing

    NARCIS (Netherlands)

    Vos, Hendrik J.

    2002-01-01

    The purpose of this paper is to derive optimal rules for sequential mastery tests. In a sequential mastery test, the decision is to classify a subject as a master, a nonmaster, or to continue sampling and administering another random item. The framework of minimax sequential decision theory (minimum

  7. Classical and sequential limit analysis revisited

    Science.gov (United States)

    Leblond, Jean-Baptiste; Kondo, Djimédo; Morin, Léo; Remmal, Almahdi

    2018-04-01

    Classical limit analysis applies to ideal plastic materials, and within a linearized geometrical framework implying small displacements and strains. Sequential limit analysis was proposed as a heuristic extension to materials exhibiting strain hardening, and within a fully general geometrical framework involving large displacements and strains. The purpose of this paper is to study and clearly state the precise conditions permitting such an extension. This is done by comparing the evolution equations of the full elastic-plastic problem, the equations of classical limit analysis, and those of sequential limit analysis. The main conclusion is that, whereas classical limit analysis applies to materials exhibiting elasticity - in the absence of hardening and within a linearized geometrical framework -, sequential limit analysis, to be applicable, strictly prohibits the presence of elasticity - although it tolerates strain hardening and large displacements and strains. For a given mechanical situation, the relevance of sequential limit analysis therefore essentially depends upon the importance of the elastic-plastic coupling in the specific case considered.

  8. Simultaneous versus sequential penetrating keratoplasty and cataract surgery.

    Science.gov (United States)

    Hayashi, Ken; Hayashi, Hideyuki

    2006-10-01

    To compare the surgical outcomes of simultaneous penetrating keratoplasty and cataract surgery with those of sequential surgery. Thirty-nine eyes of 39 patients scheduled for simultaneous keratoplasty and cataract surgery and 23 eyes of 23 patients scheduled for sequential keratoplasty and secondary phacoemulsification surgery were recruited. Refractive error, regular and irregular corneal astigmatism determined by Fourier analysis, and endothelial cell loss were studied at 1 week and 3, 6, and 12 months after combined surgery in the simultaneous surgery group or after subsequent phacoemulsification surgery in the sequential surgery group. At 3 and more months after surgery, mean refractive error was significantly greater in the simultaneous surgery group than in the sequential surgery group, although no difference was seen at 1 week. The refractive error at 12 months was within 2 D of that targeted in 15 eyes (39%) in the simultaneous surgery group and within 2 D in 16 eyes (70%) in the sequential surgery group; the incidence was significantly greater in the sequential group (P = 0.0344). The regular and irregular astigmatism was not significantly different between the groups at 3 and more months after surgery. No significant difference was also found in the percentage of endothelial cell loss between the groups. Although corneal astigmatism and endothelial cell loss were not different, refractive error from target refraction was greater after simultaneous keratoplasty and cataract surgery than after sequential surgery, indicating a better outcome after sequential surgery than after simultaneous surgery.

  9. Altering user' acceptance of automation through prior automation exposure.

    Science.gov (United States)

    Bekier, Marek; Molesworth, Brett R C

    2017-06-01

    Air navigation service providers worldwide see increased use of automation as one solution to overcome the capacity constraints imbedded in the present air traffic management (ATM) system. However, increased use of automation within any system is dependent on user acceptance. The present research sought to determine if the point at which an individual is no longer willing to accept or cooperate with automation can be manipulated. Forty participants underwent training on a computer-based air traffic control programme, followed by two ATM exercises (order counterbalanced), one with and one without the aid of automation. Results revealed after exposure to a task with automation assistance, user acceptance of high(er) levels of automation ('tipping point') decreased; suggesting it is indeed possible to alter automation acceptance. Practitioner Summary: This paper investigates whether the point at which a user of automation rejects automation (i.e. 'tipping point') is constant or can be manipulated. The results revealed after exposure to a task with automation assistance, user acceptance of high(er) levels of automation decreased; suggesting it is possible to alter automation acceptance.

  10. Determination of trace amounts of lead by chelating ion exchange and on-line preconcentration in flow-injection atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Purohit, Rajesh; Devi, Surekha

    1992-01-01

    Resins synthesized from quinolin-8-ol and resorcinol or hydro-quinone, with furfuraldehyde, formaldehyde or benzaldehyde as cross-linking agent, were used for the preconcentration of nanogram amounts of lead. The rate of exchange and activation energy of lead exchange were calculated. Column separations of lead-copper and lead-zinc did not show any cross-contamination. A continuous flow manifold using resin microcolumns was developed for the preconcentration and determination of lead. (author). 24 refs.; 5 figs.; 3 tabs

  11. Automated detection of fluorescent cells in in-resin fluorescence sections for integrated light and electron microscopy.

    Science.gov (United States)

    Delpiano, J; Pizarro, L; Peddie, C J; Jones, M L; Griffin, L D; Collinson, L M

    2018-04-26

    Integrated array tomography combines fluorescence and electron imaging of ultrathin sections in one microscope, and enables accurate high-resolution correlation of fluorescent proteins to cell organelles and membranes. Large numbers of serial sections can be imaged sequentially to produce aligned volumes from both imaging modalities, thus producing enormous amounts of data that must be handled and processed using novel techniques. Here, we present a scheme for automated detection of fluorescent cells within thin resin sections, which could then be used to drive automated electron image acquisition from target regions via 'smart tracking'. The aim of this work is to aid in optimization of the data acquisition process through automation, freeing the operator to work on other tasks and speeding up the process, while reducing data rates by only acquiring images from regions of interest. This new method is shown to be robust against noise and able to deal with regions of low fluorescence. © 2018 The Authors. Journal of Microscopy published by JohnWiley & Sons Ltd on behalf of Royal Microscopical Society.

  12. PASA - A Program for Automated Protein NMR Backbone Signal Assignment by Pattern-Filtering Approach

    International Nuclear Information System (INIS)

    Xu Yizhuang; Wang Xiaoxia; Yang Jun; Vaynberg, Julia; Qin Jun

    2006-01-01

    We present a new program, PASA (Program for Automated Sequential Assignment), for assigning protein backbone resonances based on multidimensional heteronuclear NMR data. Distinct from existing programs, PASA emphasizes a per-residue-based pattern-filtering approach during the initial stage of the automated 13 C α and/or 13 C β chemical shift matching. The pattern filter employs one or multiple constraints such as 13 C α /C β chemical shift ranges for different amino acid types and side-chain spin systems, which helps to rule out, in a stepwise fashion, improbable assignments as resulted from resonance degeneracy or missing signals. Such stepwise filtering approach substantially minimizes early false linkage problems that often propagate, amplify, and ultimately cause complication or combinatorial explosion of the automation process. Our program (http://www.lerner.ccf.org/moleccard/qin/) was tested on four representative small-large sized proteins with various degrees of resonance degeneracy and missing signals, and we show that PASA achieved the assignments efficiently and rapidly that are fully consistent with those obtained by laborious manual protocols. The results demonstrate that PASA may be a valuable tool for NMR-based structural analyses, genomics, and proteomics

  13. Trial Sequential Methods for Meta-Analysis

    Science.gov (United States)

    Kulinskaya, Elena; Wood, John

    2014-01-01

    Statistical methods for sequential meta-analysis have applications also for the design of new trials. Existing methods are based on group sequential methods developed for single trials and start with the calculation of a required information size. This works satisfactorily within the framework of fixed effects meta-analysis, but conceptual…

  14. Marker-controlled watershed for lymphoma segmentation in sequential CT images

    International Nuclear Information System (INIS)

    Yan Jiayong; Zhao Binsheng; Wang, Liang; Zelenetz, Andrew; Schwartz, Lawrence H.

    2006-01-01

    Segmentation of lymphoma containing lymph nodes is a difficult task because of multiple variables associated with the tumor's location, intensity distribution, and contrast to its surrounding tissues. In this paper, we present a reliable and practical marker-controlled watershed algorithm for semi-automated segmentation of lymphoma in sequential CT images. Robust determination of internal and external markers is the key to successful use of the marker-controlled watershed transform in the segmentation of lymphoma and is the focus of this work. The external marker in our algorithm is the circle enclosing the lymphoma in a single slice. The internal marker, however, is determined automatically by combining techniques including Canny edge detection, thresholding, morphological operation, and distance map estimation. To obtain tumor volume, the segmented lymphoma in the current slice needs to be propagated to the adjacent slice to help determine the external and internal markers for delineation of the lymphoma in that slice. The algorithm was applied to 29 lymphomas (size range, 9-53 mm in diameter; mean, 23 mm) in nine patients. A blinded radiologist manually delineated all lymphomas on all slices. The manual result served as the ''gold standard'' for comparison. Several quantitative methods were applied to objectively evaluate the performance of the segmentation algorithm. The algorithm received a mean overlap, overestimation, and underestimation ratios of 83.2%, 13.5%, and 5.5%, respectively. The mean average boundary distance and Hausdorff boundary distance were 0.7 and 3.7 mm. Preliminary results have shown the potential of this computer algorithm to allow reliable segmentation and quantification of lymphomas on sequential CT images

  15. Sequentially pulsed traveling wave accelerator

    Science.gov (United States)

    Caporaso, George J [Livermore, CA; Nelson, Scott D [Patterson, CA; Poole, Brian R [Tracy, CA

    2009-08-18

    A sequentially pulsed traveling wave compact accelerator having two or more pulse forming lines each with a switch for producing a short acceleration pulse along a short length of a beam tube, and a trigger mechanism for sequentially triggering the switches so that a traveling axial electric field is produced along the beam tube in synchronism with an axially traversing pulsed beam of charged particles to serially impart energy to the particle beam.

  16. Automated solid-phase extraction of phenolic acids using layered double hydroxide-alumina-polymer disks.

    Science.gov (United States)

    Ghani, Milad; Palomino Cabello, Carlos; Saraji, Mohammad; Manuel Estela, Jose; Cerdà, Víctor; Turnes Palomino, Gemma; Maya, Fernando

    2018-01-26

    The application of layered double hydroxide-Al 2 O 3 -polymer mixed-matrix disks for solid-phase extraction is reported for the first time. Al 2 O 3 is embedded in a polymer matrix followed by an in situ metal-exchange process to obtain a layered double hydroxide-Al 2 O 3 -polymer mixed-matrix disk with excellent flow-through properties. The extraction performance of the prepared disks is evaluated as a proof of concept for the automated extraction using sequential injection analysis of organic acids (p-hydroxybenzoic acid, 3,4-dihydroxybenzoic acid, gallic acid) following an anion-exchange mechanism. After the solid-phase extraction, phenolic acids were quantified by reversed-phase high-performance liquid chromatography with diode-array detection using a core-shell silica-C18 stationary phase and isocratic elution (acetonitrile/0.5% acetic acid in pure water, 5:95, v/v). High sensitivity and reproducibility were obtained with limits of detection in the range of 0.12-0.25 μg/L (sample volume, 4 mL), and relative standard deviations between 2.9 and 3.4% (10 μg/L, n = 6). Enrichment factors of 34-39 were obtained. Layered double hydroxide-Al 2 O 3 -polymer mixed-matrix disks had an average lifetime of 50 extractions. Analyte recoveries ranged from 93 to 96% for grape juice and nonalcoholic beer samples. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Complacency and Automation Bias in the Use of Imperfect Automation.

    Science.gov (United States)

    Wickens, Christopher D; Clegg, Benjamin A; Vieane, Alex Z; Sebok, Angelia L

    2015-08-01

    We examine the effects of two different kinds of decision-aiding automation errors on human-automation interaction (HAI), occurring at the first failure following repeated exposure to correctly functioning automation. The two errors are incorrect advice, triggering the automation bias, and missing advice, reflecting complacency. Contrasts between analogous automation errors in alerting systems, rather than decision aiding, have revealed that alerting false alarms are more problematic to HAI than alerting misses are. Prior research in decision aiding, although contrasting the two aiding errors (incorrect vs. missing), has confounded error expectancy. Participants performed an environmental process control simulation with and without decision aiding. For those with the aid, automation dependence was created through several trials of perfect aiding performance, and an unexpected automation error was then imposed in which automation was either gone (one group) or wrong (a second group). A control group received no automation support. The correct aid supported faster and more accurate diagnosis and lower workload. The aid failure degraded all three variables, but "automation wrong" had a much greater effect on accuracy, reflecting the automation bias, than did "automation gone," reflecting the impact of complacency. Some complacency was manifested for automation gone, by a longer latency and more modest reduction in accuracy. Automation wrong, creating the automation bias, appears to be a more problematic form of automation error than automation gone, reflecting complacency. Decision-aiding automation should indicate its lower degree of confidence in uncertain environments to avoid the automation bias. © 2015, Human Factors and Ergonomics Society.

  18. Determination of Low Level Concentrations of Metals by Means of Sequential Injection (SI) and Lab-on-Valve (LOV) Methodologies

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Miró, Manuel; Petersen, Roongrat

    /emission spectrometry (FAAS, ETAAS, ICP-AES, ICP-MS). The lecture will initially give an overview of various automated alternatives for facilitating appropriate SI/LOV-separation and pre-concentration schemes of metals in liquid samples, including examples of solid-phase extraction with permanent columns or renewable...

  19. An Efficient System Based On Closed Sequential Patterns for Web Recommendations

    OpenAIRE

    Utpala Niranjan; R.B.V. Subramanyam; V-Khana

    2010-01-01

    Sequential pattern mining, since its introduction has received considerable attention among the researchers with broad applications. The sequential pattern algorithms generally face problems when mining long sequential patterns or while using very low support threshold. One possible solution of such problems is by mining the closed sequential patterns, which is a condensed representation of sequential patterns. Recently, several researchers have utilized the sequential pattern discovery for d...

  20. MHD simulation study of compact toroid injection into magnetized plasmas

    International Nuclear Information System (INIS)

    Suzuki, Yoshio; Kishimoto, Yasuaki

    2000-01-01

    To understand the fuelling process in a fusion device by a compact toroid (CT) plasmoid injection method, we have carried out MHD numerical simulations where a spheromak-like CT (SCT) is injected into a magnetized target plasma region. So far, we revealed that the penetration depth of the SCT plasma becomes shorter than that estimated from the conducting sphere (CS) model, because in the simulation the Lorentz force of the target magnetic field sequentially decelerates the injected SCT while in the CS model only the magnetic pressure force acts as the deceleration mechanism. In this study, we represent the new theoretical model where the injected SCT is decelerated by both the magnetic pressure force and the magnetic tension force (we call it the non-slipping sphere (NS) model) and investigate in detail the deceleration mechanism of the SCT by comparison with simulation results. As a result, it is found that the decrease of the SCT kinetic energy in the simulation coincides with that in the NS model more than in the CS model. It means that not only the magnetic pressure force but also the magnetic tension force acts as the deceleration mechanism of the SCT. Furthermore, it is revealed that magnetic reconnection between the SCT magnetic field and the target magnetic field plays a role to relax the SCT deceleration. (author)

  1. Automated spectrophotometer for plutonium and uranium determination

    International Nuclear Information System (INIS)

    Jackson, D.D.; Hodgkins, D.J.; Hollen, R.M.; Rein, J.E.

    1975-09-01

    The automated spectrophotometer described is the first in a planned series of automated instruments for determining plutonium and uranium in nuclear fuel cycle materials. It has a throughput rate of 5 min per sample and uses a highly specific method of analysis for these elements. The range of plutonium and uranium measured is 0.5 to 14 mg and 1 to 14 mg, respectively, in 0.5 ml or less of solution with an option to pre-evaporate larger volumes. The precision of the measurements is about 0.02 mg standard deviation over the range corresponding to about 2 rel percent at the 1-mg level and 0.2 rel percent at the 10-mg level. The method of analysis involves the extraction of tetrapropylammonium plutonyl and uranyl trinitrate complexes into 2-nitropropane and the measurement of the optical absorbances in the organic phase at unique peak wavelengths. Various aspects of the chemistry associated with the method are presented. The automated spectrophotometer features a turntable that rotates as many as 24 samples in tubes to a series of stations for the sequential chemical operations of reagent addition and phase mixing to effect extraction, and then to a station for the absorbance measurement. With this system, the complications of sample transfers and flow-through cells are avoided. The absorbance measurement system features highly stable interference filters and a microcomputer that controls the timing sequence and operation of the system components. Output is a paper tape printout of three numbers: a four-digit number proportional to the quantity of plutonium or uranium, a two-digit number that designates the position of the tube in the turntable, and a one-digit number that designates whether plutonium or uranium was determined. Details of the mechanical and electrical components of the instrument and of the hardware and software aspects of the computerized control system are provided

  2. Improving the driver-automation interaction: an approach using automation uncertainty.

    Science.gov (United States)

    Beller, Johannes; Heesen, Matthias; Vollrath, Mark

    2013-12-01

    The aim of this study was to evaluate whether communicating automation uncertainty improves the driver-automation interaction. A false system understanding of infallibility may provoke automation misuse and can lead to severe consequences in case of automation failure. The presentation of automation uncertainty may prevent this false system understanding and, as was shown by previous studies, may have numerous benefits. Few studies, however, have clearly shown the potential of communicating uncertainty information in driving. The current study fills this gap. We conducted a driving simulator experiment, varying the presented uncertainty information between participants (no uncertainty information vs. uncertainty information) and the automation reliability (high vs.low) within participants. Participants interacted with a highly automated driving system while engaging in secondary tasks and were required to cooperate with the automation to drive safely. Quantile regressions and multilevel modeling showed that the presentation of uncertainty information increases the time to collision in the case of automation failure. Furthermore, the data indicated improved situation awareness and better knowledge of fallibility for the experimental group. Consequently, the automation with the uncertainty symbol received higher trust ratings and increased acceptance. The presentation of automation uncertaintythrough a symbol improves overall driver-automation cooperation. Most automated systems in driving could benefit from displaying reliability information. This display might improve the acceptance of fallible systems and further enhances driver-automation cooperation.

  3. Discrimination between sequential and simultaneous virtual channels with electrical hearing.

    Science.gov (United States)

    Landsberger, David; Galvin, John J

    2011-09-01

    In cochlear implants (CIs), simultaneous or sequential stimulation of adjacent electrodes can produce intermediate pitch percepts between those of the component electrodes. However, it is unclear whether simultaneous and sequential virtual channels (VCs) can be discriminated. In this study, CI users were asked to discriminate simultaneous and sequential VCs; discrimination was measured for monopolar (MP) and bipolar + 1 stimulation (BP + 1), i.e., relatively broad and focused stimulation modes. For sequential VCs, the interpulse interval (IPI) varied between 0.0 and 1.8 ms. All stimuli were presented at comfortably loud, loudness-balanced levels at a 250 pulse per second per electrode (ppse) stimulation rate. On average, CI subjects were able to reliably discriminate between sequential and simultaneous VCs. While there was no significant effect of IPI or stimulation mode on VC discrimination, some subjects exhibited better VC discrimination with BP + 1 stimulation. Subjects' discrimination between sequential and simultaneous VCs was correlated with electrode discrimination, suggesting that spatial selectivity may influence perception of sequential VCs. To maintain equal loudness, sequential VC amplitudes were nearly double those of simultaneous VCs, presumably resulting in a broader spread of excitation. These results suggest that perceptual differences between simultaneous and sequential VCs might be explained by differences in the spread of excitation. © 2011 Acoustical Society of America

  4. Sequential versus simultaneous market delineation

    DEFF Research Database (Denmark)

    Haldrup, Niels; Møllgaard, Peter; Kastberg Nielsen, Claus

    2005-01-01

    and geographical markets. Using a unique data setfor prices of Norwegian and Scottish salmon, we propose a methodologyfor simultaneous market delineation and we demonstrate that comparedto a sequential approach conclusions will be reversed.JEL: C3, K21, L41, Q22Keywords: Relevant market, econometric delineation......Delineation of the relevant market forms a pivotal part of most antitrustcases. The standard approach is sequential. First the product marketis delineated, then the geographical market is defined. Demand andsupply substitution in both the product dimension and the geographicaldimension...

  5. Video and accelerometer-based motion analysis for automated surgical skills assessment.

    Science.gov (United States)

    Zia, Aneeq; Sharma, Yachna; Bettadapura, Vinay; Sarin, Eric L; Essa, Irfan

    2018-03-01

    Basic surgical skills of suturing and knot tying are an essential part of medical training. Having an automated system for surgical skills assessment could help save experts time and improve training efficiency. There have been some recent attempts at automated surgical skills assessment using either video analysis or acceleration data. In this paper, we present a novel approach for automated assessment of OSATS-like surgical skills and provide an analysis of different features on multi-modal data (video and accelerometer data). We conduct a large study for basic surgical skill assessment on a dataset that contained video and accelerometer data for suturing and knot-tying tasks. We introduce "entropy-based" features-approximate entropy and cross-approximate entropy, which quantify the amount of predictability and regularity of fluctuations in time series data. The proposed features are compared to existing methods of Sequential Motion Texture, Discrete Cosine Transform and Discrete Fourier Transform, for surgical skills assessment. We report average performance of different features across all applicable OSATS-like criteria for suturing and knot-tying tasks. Our analysis shows that the proposed entropy-based features outperform previous state-of-the-art methods using video data, achieving average classification accuracies of 95.1 and 92.2% for suturing and knot tying, respectively. For accelerometer data, our method performs better for suturing achieving 86.8% average accuracy. We also show that fusion of video and acceleration features can improve overall performance for skill assessment. Automated surgical skills assessment can be achieved with high accuracy using the proposed entropy features. Such a system can significantly improve the efficiency of surgical training in medical schools and teaching hospitals.

  6. Online preconcentration and determination of trace levels cadmium in water samples using flow injection systems coupled with flame AAS

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Songlin; Liang, Huading; Yan, Hua; Yan, Zhengzhong; Chen, Suqing; Zhu, Xiandi; Cheng, Miaoxian [School of Pharmaceutical and Chemical Engineering, Taizhou University (China)

    2010-02-15

    A rapid and sensitive method for the determination of trace levels cadmium in water samples by flame atomic absorption spectrometry was developed. It is based on the online sorption of Cd(II) ions on a microcolumn packed with HCl treated bamboo charcoal. In a pH range of 5.0-7.5, Cd(II) ions were effectively retained on the microcolumn, which exhibited fast kinetics, permitting the use of high sample flow rates up to at least 12.8 mL/min without the loss of retention efficiency. The retained Cd(II) ions were quantitatively eluted with HCl (2.0 mol/L) for an online determination. With a preconcentration time of 80 s at a sample loading flow rate of 8.6 mL/min, a sensitivity enhancement factor of 63 was obtained compared with the slope of the linear portion of the calibration curves before and after preconcentration. The calibration graph using the preconcentration system for cadmium was linear with a correlation coefficient of 0.9997, at levels from 1-40 ng/mL. The precision (RSD) for 11 replicate measurements were 3.2% for the determination of 5 ng/mL Cd(II) and 1.8% for 20 ng/mL Cd(II), respectively, and the detection limit (3s) was 0.36 ng/mL. The accuracy was assessed through the determination of a certified reference material, and also through recovery experiments. (Abstract Copyright [2010], Wiley Periodicals, Inc.)

  7. Group-sequential analysis may allow for early trial termination

    DEFF Research Database (Denmark)

    Gerke, Oke; Vilstrup, Mie H; Halekoh, Ulrich

    2017-01-01

    BACKGROUND: Group-sequential testing is widely used in pivotal therapeutic, but rarely in diagnostic research, although it may save studies, time, and costs. The purpose of this paper was to demonstrate a group-sequential analysis strategy in an intra-observer study on quantitative FDG-PET/CT mea......BACKGROUND: Group-sequential testing is widely used in pivotal therapeutic, but rarely in diagnostic research, although it may save studies, time, and costs. The purpose of this paper was to demonstrate a group-sequential analysis strategy in an intra-observer study on quantitative FDG...

  8. Sequential logic analysis and synthesis

    CERN Document Server

    Cavanagh, Joseph

    2007-01-01

    Until now, there was no single resource for actual digital system design. Using both basic and advanced concepts, Sequential Logic: Analysis and Synthesis offers a thorough exposition of the analysis and synthesis of both synchronous and asynchronous sequential machines. With 25 years of experience in designing computing equipment, the author stresses the practical design of state machines. He clearly delineates each step of the structured and rigorous design principles that can be applied to practical applications. The book begins by reviewing the analysis of combinatorial logic and Boolean a

  9. Transient Tolerant Automated Control System for the LEDA 75kV Injector

    International Nuclear Information System (INIS)

    Thuot, M.E.; Dalesio, L.R.; Harrington, M.; Hodgkins, D.; Kerstiens, D.M.; Stettler, M.W.; Warren, D.S.; Zaugg, T.; Arvin, A.; Bolt, S.; Richards, M.

    1999-01-01

    The Low-Energy Demonstration Accelerator (LEDA) injector is designed to inject 75-keV, 110-mA, proton beams into the LEDA RFQ. The injector operation has been automated to provide long term, high availability operation using the Experimental Physics and Industrial Control System (EPICS). Automated recovery from spark-downs demands reliable spark detection and sequence execution by the injector controller. Reliable computer control in the high-energy transient environment required transient suppression and isolation of hundreds of analog and binary data lines connecting the EPICS computer controller to the injector and it's power supplies and diagnostics. A transient suppression design based on measured and modeled spark transient parameters provides robust injector operation. This paper describes the control system hardware and software design, implementation and operational performance

  10. AdOn HDP-HMM: An Adaptive Online Model for Segmentation and Classification of Sequential Data.

    Science.gov (United States)

    Bargi, Ava; Xu, Richard Yi Da; Piccardi, Massimo

    2017-09-21

    Recent years have witnessed an increasing need for the automated classification of sequential data, such as activities of daily living, social media interactions, financial series, and others. With the continuous flow of new data, it is critical to classify the observations on-the-fly and without being limited by a predetermined number of classes. In addition, a model should be able to update its parameters in response to a possible evolution in the distributions of the classes. This compelling problem, however, does not seem to have been adequately addressed in the literature, since most studies focus on offline classification over predefined class sets. In this paper, we present a principled solution for this problem based on an adaptive online system leveraging Markov switching models and hierarchical Dirichlet process priors. This adaptive online approach is capable of classifying the sequential data over an unlimited number of classes while meeting the memory and delay constraints typical of streaming contexts. In this paper, we introduce an adaptive ''learning rate'' that is responsible for balancing the extent to which the model retains its previous parameters or adapts to new observations. Experimental results on stationary and evolving synthetic data and two video data sets, TUM Assistive Kitchen and collated Weizmann, show a remarkable performance in terms of segmentation and classification, particularly for sequences from evolutionary distributions and/or those containing previously unseen classes.

  11. Structural Consistency, Consistency, and Sequential Rationality.

    OpenAIRE

    Kreps, David M; Ramey, Garey

    1987-01-01

    Sequential equilibria comprise consistent beliefs and a sequentially ra tional strategy profile. Consistent beliefs are limits of Bayes ratio nal beliefs for sequences of strategies that approach the equilibrium strategy. Beliefs are structurally consistent if they are rationaliz ed by some single conjecture concerning opponents' strategies. Consis tent beliefs are not necessarily structurally consistent, notwithstan ding a claim by Kreps and Robert Wilson (1982). Moreover, the spirit of stru...

  12. Summary of dosimetry, pathology, and dose response for bone sarcomas in beagles injected with radium-226

    International Nuclear Information System (INIS)

    Wrenn, M.E.; Taylor, G.N.; Stevens, W.

    1986-01-01

    In the completed 226 Ra portion of a 30-year-long experiment to determine the relative radiotoxicity of injected 226 Ra and 239 Pu, 42 of 116 animals injected with 226 Ra developed 63 bone sarcomas; none were observed in 44 controls. Average alpha plus beta dose to the skeleton to death was calculated on the basis of mathematical functions developed from sequential measurements of radium and radon retention in each dog. Bone sarcomas were identified radiographically or clinically, with subsequent histopathological confirmation and classification. Most primary bone tumors were classified as osteosarcomas if osteoid arose from a malignant stroma. The dose-response curve over the six lowest injected dose levels fits well to a linear, no-threshold, least squares fit, through a control incidence of 0.8%, and with a slope of 0.042% incidence per rad. 19 refs., 5 figs., 2 tabs

  13. Analysis of influencing factors on schizophrenia patients with sequential therapy of ziprasidone%齐拉西酮序贯治疗精神分裂症患者的影响因素分析

    Institute of Scientific and Technical Information of China (English)

    徐佳; 李越; 付春凤; 于春岩; 张聪沛

    2016-01-01

    Objective To observe curative effect of applying sequential therapy of oral dosage forms after the aiprasidone mesylate injection treatment for people with schiaophreniaand and analysis the influencing factors for providing clinical basis in reasonable application of sequential treatment. Methods Totally 40 patients with schiaophrenia according to the Diagnostic and Statistical Manual of Mental Disorders Fourth edition(DSM - IV)who mainly showed symptoms of excitation and agitation were evaluated using Positive and Negative Syndrome Scale(PANSS). General situation questionnaire was used to investigate patients before treatment(baseline).After 72 hours of aiprasidone mesylate injection treatment,sequential therapy was conducted with oral aiprasidone. Patients were assess ed using PANSS at baseline and 72 hours after treatment of intramuscular injection. Side effects were assessed with Treatment Emergent Symptom Scale(TESS). Results 24 patients were succeeded in the sequential treatment. There were 16 patients whose therapeutic effect were poor because of the efficacy and tolerance of treatment,in which 7 patients’treatment were changed with another second generation of atypical antipsychotics. Second sequential therapy were applied to another 9 patients after 3 days therapy of aiprasidone mesylate for injection,in which 5 patients were succeeded and 4 patients’treatments were replaced with another second generation of atypical antipsychotics. Conclusion The second injection treatment can be applied to the patients who were not succeed in the first sequential therapy and some patients were succeeded in the second sequential therapy. The efficacy of sequential therapy is associated with patients’weight,drinking habits and whether first - episode. It is also related to other factor except injection factors,such as the relationship between patients and doctors,quality of the therapeutic alliance

  14. Target injection and tracking for inertial fusion energy

    Energy Technology Data Exchange (ETDEWEB)

    Petzoldt, R.W. [Lawrence Livermore National Lab., CA (United States); Moir, R.W. [Lawrence Livermore National Lab., CA (United States)

    1996-11-01

    In an inertial fusion power plant, several cryogenic targets must be injected each second into a reaction chamber with speeds of about 100 m s{sup -1}. This speed can be achieved with an acceleration in the range from 1000 to 10 000 m s{sup -2}. The total accuracy of driver beam pointing and target position prediction must be less than {+-}0.6 mm for a 3 mm beam spot radius. A 0.1 {mu}m thick dual membrane supporting the capsule in the hohlraum will allow nearly 2000 m s{sup -2} acceleration. The strength of frozen DT in the capsule is calculated to allow acceleration in excess of 10 000 m s{sup -2} if the DT temperature is less than 17 K. A gas gun is the preferred device for injecting indirect drive targets owing to its simplicity and proven reliability. The amount of gas required for each target (about 10-100 mg) is acceptable. A revolver loading mechanism is recommendced with a cam-operated poppet valve to control the gas flow. Slots near the muzzle of the gun barrel are recommended to vent gas and thereby to improve accuracy and to aid gas pumping. Optical target tracking and electronic timing devices can predict target arrival time with sufficient accuracy. Target steering by electrostatic deflection of the in-flight target is shown to be feasible and would avoid the need to point the beams actively. Calculations show that induced tumble from electrostatically steering the target is not excessive. An experiment has been designed to develop target injection and to verify the predicted accuracy of sequential injection and tracking of multiple targets. (orig.)

  15. Metamodel-based design optimization of injection molding process variables and gates of an automotive glove box for enhancing its quality

    International Nuclear Information System (INIS)

    Kang, Gyung Ju; Park, Chang Hyun; Choi, Dong Hoon

    2016-01-01

    Injection molding process variables and gates of an automotive glove box were optimally determined to enhance its injection molding quality. We minimized warpage with satisfying constraints on clamp force, weldline, and profiles of filling and packing. Design variables concerning the injection molding process are temperatures of the mold and the resin, ram speeds, and packing pressures and durations; design variables concerning the gates are the shape of the center gate and locations of two side gates. To optimally determine the design variables in an efficient way, we adopted metamodel-based design optimization, sequentially using an optimal Latin hypercube design as a design of experiment, Kriging models as metamodels that replace time-consuming injection molding simulations, and a micro genetic algorithm as an optimization algorithm. In the optimization process, a commercial injection molding analysis software, MoldflowTM, was employed to evaluate the injection molding quality at design points specified. Using the proposed design approach, the warpage was found reduced by 20.5% compared to the initial warpage, while all the design constraints were satisfied, which clearly shows the validity of the proposed design approach

  16. Metamodel-based design optimization of injection molding process variables and gates of an automotive glove box for enhancing its quality

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Gyung Ju [Pusan National University, Busan (Korea, Republic of); Park, Chang Hyun; Choi, Dong Hoon [Hanyang University, Seoul (Korea, Republic of)

    2016-04-15

    Injection molding process variables and gates of an automotive glove box were optimally determined to enhance its injection molding quality. We minimized warpage with satisfying constraints on clamp force, weldline, and profiles of filling and packing. Design variables concerning the injection molding process are temperatures of the mold and the resin, ram speeds, and packing pressures and durations; design variables concerning the gates are the shape of the center gate and locations of two side gates. To optimally determine the design variables in an efficient way, we adopted metamodel-based design optimization, sequentially using an optimal Latin hypercube design as a design of experiment, Kriging models as metamodels that replace time-consuming injection molding simulations, and a micro genetic algorithm as an optimization algorithm. In the optimization process, a commercial injection molding analysis software, MoldflowTM, was employed to evaluate the injection molding quality at design points specified. Using the proposed design approach, the warpage was found reduced by 20.5% compared to the initial warpage, while all the design constraints were satisfied, which clearly shows the validity of the proposed design approach.

  17. Human/Automation Trade Methodology for the Moon, Mars and Beyond

    Science.gov (United States)

    Korsmeyer, David J.

    2009-01-01

    It is possible to create a consistent trade methodology that can characterize operations model alternatives for crewed exploration missions. For example, a trade-space that is organized around the objective of maximizing Crew Exploration Vehicle (CEV) independence would have the input as a classification of the category of analysis to be conducted or decision to be made, and a commitment to a detailed point in a mission profile during which the analysis or decision is to be made. For example, does the decision have to do with crew activity planning, or life support? Is the mission phase trans-Earth injection, cruise, or lunar descent? Different kinds of decision analysis of the trade-space between human and automated decisions will occurs at different points in a mission's profile. The necessary objectives at a given point in time during a mission will call for different kinds of response with respect to where and how computers and automation are expected to help provide an accurate, safe, and timely response. In this paper, a consistent methodology for assessing the trades between human and automated decisions on-board will be presented and various examples discussed.

  18. Lightning Pin Injection Testing on MOSFETS

    Science.gov (United States)

    Ely, Jay J.; Nguyen, Truong X.; Szatkowski, George N.; Koppen, Sandra V.; Mielnik, John J.; Vaughan, Roger K.; Wysocki, Philip F.; Celaya, Jose R.; Saha, Sankalita

    2009-01-01

    Lightning transients were pin-injected into metal-oxide-semiconductor field-effect transistors (MOSFETs) to induce fault modes. This report documents the test process and results, and provides a basis for subsequent lightning tests. MOSFETs may be present in DC-DC power supplies and electromechanical actuator circuits that may be used on board aircraft. Results show that unprotected MOSFET Gates are susceptible to failure, even when installed in systems in well-shielded and partial-shielded locations. MOSFET Drains and Sources are significantly less susceptible. Device impedance decreased (current increased) after every failure. Such a failure mode may lead to cascading failures, as the damaged MOSFET may allow excessive current to flow through other circuitry. Preliminary assessments on a MOSFET subjected to 20-stroke pin-injection testing demonstrate that Breakdown Voltage, Leakage Current and Threshold Voltage characteristics show damage, while the device continues to meet manufacturer performance specifications. The purpose of this research is to develop validated tools, technologies, and techniques for automated detection, diagnosis and prognosis that enable mitigation of adverse events during flight, such as from lightning transients; and to understand the interplay between lightning-induced surges and aging (i.e. humidity, vibration thermal stress, etc.) on component degradation.

  19. Generalized infimum and sequential product of quantum effects

    International Nuclear Information System (INIS)

    Li Yuan; Sun Xiuhong; Chen Zhengli

    2007-01-01

    The quantum effects for a physical system can be described by the set E(H) of positive operators on a complex Hilbert space H that are bounded above by the identity operator I. For A, B(set-membership sign)E(H), the operation of sequential product A(convolution sign)B=A 1/2 BA 1/2 was proposed as a model for sequential quantum measurements. A nice investigation of properties of the sequential product has been carried over [Gudder, S. and Nagy, G., 'Sequential quantum measurements', J. Math. Phys. 42, 5212 (2001)]. In this note, we extend some results of this reference. In particular, a gap in the proof of Theorem 3.2 in this reference is overcome. In addition, some properties of generalized infimum A sqcap B are studied

  20. Immunogenicity of simultaneous versus sequential administration of a 23-valent pneumococcal polysaccharide vaccine and a quadrivalent influenza vaccine in older individuals: A randomized, open-label, non-inferiority trial.

    Science.gov (United States)

    Nakashima, Kei; Aoshima, Masahiro; Ohfuji, Satoko; Yamawaki, Satoshi; Nemoto, Masahiro; Hasegawa, Shinya; Noma, Satoshi; Misawa, Masafumi; Hosokawa, Naoto; Yaegashi, Makito; Otsuka, Yoshihito

    2018-03-21

    It is unclear whether simultaneous administration of a 23-valent pneumococcal polysaccharide vaccine (PPSV23) and a quadrivalent influenza vaccine (QIV) produces immunogenicity in older individuals. This study tested the hypothesis that the pneumococcal antibody response elicited by simultaneous administration of PPSV23 and QIV in older individuals is not inferior to that elicited by sequential administration of PPSV23 and QIV. We performed a single-center, randomized, open-label, non-inferiority trial comprising 162 adults aged ≥65 years randomly assigned to either the simultaneous (simultaneous injections of PPSV23 and QIV) or sequential (control; PPSV23 injected 2 weeks after QIV vaccination) groups. Pneumococcal immunoglobulin G (IgG) titers of serotypes 23F, 3, 4, 6B, 14, and 19A were assessed. The primary endpoint was the serotype 23F response rate (a ≥2-fold increase in IgG concentrations 4-6 weeks after PPSV23 vaccination). With the non-inferiority margin set at 20% fewer patients, the response rate of serotype 23F in the simultaneous group (77.8%) was not inferior to that of the sequential group (77.6%; difference, 0.1%; 90% confidence interval, -10.8% to 11.1%). None of the pneumococcal IgG serotype titers were significantly different between the groups 4-6 weeks after vaccination. Simultaneous administration did not show a significant decrease in seroprotection odds ratios for H1N1, H3N2, or B/Phuket influenza strains other than B/Texas. Additionally, simultaneous administration did not increase adverse reactions. Hence, simultaneous administration of PPSV23 and QIV shows an acceptable immunogenicity that is comparable to sequential administration without an increase in adverse reactions. (This study was registered with ClinicalTrials.gov [NCT02592486]).

  1. Sequential Scintigraphy in Renal Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Winkel, K. zum; Harbst, H.; Schenck, P.; Franz, H. E.; Ritz, E.; Roehl, L.; Ziegler, M.; Ammann, W.; Maier-Borst, W. [Institut Fuer Nuklearmedizin, Deutsches Krebsforschungszentrum, Heidelberg, Federal Republic of Germany (Germany)

    1969-05-15

    Based on experience gained from more than 1600 patients with proved or suspected kidney diseases and on results on extended studies with dogs, sequential scintigraphy was performed after renal transplantation in dogs. After intravenous injection of 500 {mu}Ci. {sup 131}I-Hippuran scintiphotos were taken during the first minute with an exposure time of 15 sec each and thereafter with an exposure of 2 min up to at least 16 min.. Several examinations were evaluated digitally. 26 examinations were performed on 11 dogs with homotransplanted kidneys. Immediately after transplantation the renal function was almost normal arid the bladder was filled in due time. At the beginning of rejection the initial uptake of radioactive Hippuran was reduced. The intrarenal transport became delayed; probably the renal extraction rate decreased. Corresponding to the development of an oedema in the transplant the uptake area increased in size. In cases of thrombosis of the main artery there was no evidence of any uptake of radioactivity in the transplant. Similar results were obtained in 41 examinations on 15 persons. Patients with postoperative anuria due to acute tubular necrosis showed still some uptake of radioactivity contrary to those with thrombosis of the renal artery, where no uptake was found. In cases of rejection the most frequent signs were a reduced initial uptake and a delayed intrarenal transport of radioactive Hippuran. Infarction could be detected by a reduced uptake in distinct areas of the transplant. (author)

  2. Prospective validation of a near real-time EHR-integrated automated SOFA score calculator.

    Science.gov (United States)

    Aakre, Christopher; Franco, Pablo Moreno; Ferreyra, Micaela; Kitson, Jaben; Li, Man; Herasevich, Vitaly

    2017-07-01

    We created an algorithm for automated Sequential Organ Failure Assessment (SOFA) score calculation within the Electronic Health Record (EHR) to facilitate detection of sepsis based on the Third International Consensus Definitions for Sepsis and Septic Shock (SEPSIS-3) clinical definition. We evaluated the accuracy of near real-time and daily automated SOFA score calculation compared with manual score calculation. Automated SOFA scoring computer programs were developed using available EHR data sources and integrated into a critical care focused patient care dashboard at Mayo Clinic in Rochester, Minnesota. We prospectively compared the accuracy of automated versus manual calculation for a sample of patients admitted to the medical intensive care unit at Mayo Clinic Hospitals in Rochester, Minnesota and Jacksonville, Florida. Agreement was calculated with Cohen's kappa statistic. Reason for discrepancy was tabulated during manual review. Random spot check comparisons were performed 134 times on 27 unique patients, and daily SOFA score comparisons were performed for 215 patients over a total of 1206 patient days. Agreement between automatically scored and manually scored SOFA components for both random spot checks (696 pairs, κ=0.89) and daily calculation (5972 pairs, κ=0.89) was high. The most common discrepancies were in the respiratory component (inaccurate fraction of inspired oxygen retrieval; 200/1206) and creatinine (normal creatinine in patients with no urine output on dialysis; 128/1094). 147 patients were at risk of developing sepsis after intensive care unit admission, 10 later developed sepsis confirmed by chart review. All were identified before onset of sepsis with the ΔSOFA≥2 point criterion and 46 patients were false-positives. Near real-time automated SOFA scoring was found to have strong agreement with manual score calculation and may be useful for the detection of sepsis utilizing the new SEPSIS-3 definition. Copyright © 2017 Elsevier B.V. All

  3. Low cost automation

    International Nuclear Information System (INIS)

    1987-03-01

    This book indicates method of building of automation plan, design of automation facilities, automation and CHIP process like basics of cutting, NC processing machine and CHIP handling, automation unit, such as drilling unit, tapping unit, boring unit, milling unit and slide unit, application of oil pressure on characteristics and basic oil pressure circuit, application of pneumatic, automation kinds and application of process, assembly, transportation, automatic machine and factory automation.

  4. Sequential bottom-up assembly of mechanically stabilized synthetic cells by microfluidics

    Science.gov (United States)

    Weiss, Marian; Frohnmayer, Johannes Patrick; Benk, Lucia Theresa; Haller, Barbara; Janiesch, Jan-Willi; Heitkamp, Thomas; Börsch, Michael; Lira, Rafael B.; Dimova, Rumiana; Lipowsky, Reinhard; Bodenschatz, Eberhard; Baret, Jean-Christophe; Vidakovic-Koch, Tanja; Sundmacher, Kai; Platzman, Ilia; Spatz, Joachim P.

    2018-01-01

    Compartments for the spatially and temporally controlled assembly of biological processes are essential towards cellular life. Synthetic mimics of cellular compartments based on lipid-based protocells lack the mechanical and chemical stability to allow their manipulation into a complex and fully functional synthetic cell. Here, we present a high-throughput microfluidic method to generate stable, defined sized liposomes termed `droplet-stabilized giant unilamellar vesicles (dsGUVs)’. The enhanced stability of dsGUVs enables the sequential loading of these compartments with biomolecules, namely purified transmembrane and cytoskeleton proteins by microfluidic pico-injection technology. This constitutes an experimental demonstration of a successful bottom-up assembly of a compartment with contents that would not self-assemble to full functionality when simply mixed together. Following assembly, the stabilizing oil phase and droplet shells are removed to release functional self-supporting protocells to an aqueous phase, enabling them to interact with physiologically relevant matrices.

  5. Sequential analysis in neonatal research-systematic review.

    Science.gov (United States)

    Lava, Sebastiano A G; Elie, Valéry; Ha, Phuong Thi Viet; Jacqz-Aigrain, Evelyne

    2018-05-01

    As more new drugs are discovered, traditional designs come at their limits. Ten years after the adoption of the European Paediatric Regulation, we performed a systematic review on the US National Library of Medicine and Excerpta Medica database of sequential trials involving newborns. Out of 326 identified scientific reports, 21 trials were included. They enrolled 2832 patients, of whom 2099 were analyzed: the median number of neonates included per trial was 48 (IQR 22-87), median gestational age was 28.7 (IQR 27.9-30.9) weeks. Eighteen trials used sequential techniques to determine sample size, while 3 used continual reassessment methods for dose-finding. In 16 studies reporting sufficient data, the sequential design allowed to non-significantly reduce the number of enrolled neonates by a median of 24 (31%) patients (IQR - 4.75 to 136.5, p = 0.0674) with respect to a traditional trial. When the number of neonates finally included in the analysis was considered, the difference became significant: 35 (57%) patients (IQR 10 to 136.5, p = 0.0033). Sequential trial designs have not been frequently used in Neonatology. They might potentially be able to reduce the number of patients in drug trials, although this is not always the case. What is known: • In evaluating rare diseases in fragile populations, traditional designs come at their limits. About 20% of pediatric trials are discontinued, mainly because of recruitment problems. What is new: • Sequential trials involving newborns were infrequently used and only a few (n = 21) are available for analysis. • The sequential design allowed to non-significantly reduce the number of enrolled neonates by a median of 24 (31%) patients (IQR - 4.75 to 136.5, p = 0.0674).

  6. Group-sequential analysis may allow for early trial termination

    DEFF Research Database (Denmark)

    Gerke, Oke; Vilstrup, Mie H; Halekoh, Ulrich

    2017-01-01

    BACKGROUND: Group-sequential testing is widely used in pivotal therapeutic, but rarely in diagnostic research, although it may save studies, time, and costs. The purpose of this paper was to demonstrate a group-sequential analysis strategy in an intra-observer study on quantitative FDG-PET/CT mea......BACKGROUND: Group-sequential testing is widely used in pivotal therapeutic, but rarely in diagnostic research, although it may save studies, time, and costs. The purpose of this paper was to demonstrate a group-sequential analysis strategy in an intra-observer study on quantitative FDG...... assumed to be normally distributed, and sequential one-sided hypothesis tests on the population standard deviation of the differences against a hypothesised value of 1.5 were performed, employing an alpha spending function. The fixed-sample analysis (N = 45) was compared with the group-sequential analysis...... strategies comprising one (at N = 23), two (at N = 15, 30), or three interim analyses (at N = 11, 23, 34), respectively, which were defined post hoc. RESULTS: When performing interim analyses with one third and two thirds of patients, sufficient agreement could be concluded after the first interim analysis...

  7. flowClust: a Bioconductor package for automated gating of flow cytometry data

    Directory of Open Access Journals (Sweden)

    Lo Kenneth

    2009-05-01

    Full Text Available Abstract Background As a high-throughput technology that offers rapid quantification of multidimensional characteristics for millions of cells, flow cytometry (FCM is widely used in health research, medical diagnosis and treatment, and vaccine development. Nevertheless, there is an increasing concern about the lack of appropriate software tools to provide an automated analysis platform to parallelize the high-throughput data-generation platform. Currently, to a large extent, FCM data analysis relies on the manual selection of sequential regions in 2-D graphical projections to extract the cell populations of interest. This is a time-consuming task that ignores the high-dimensionality of FCM data. Results In view of the aforementioned issues, we have developed an R package called flowClust to automate FCM analysis. flowClust implements a robust model-based clustering approach based on multivariate t mixture models with the Box-Cox transformation. The package provides the functionality to identify cell populations whilst simultaneously handling the commonly encountered issues of outlier identification and data transformation. It offers various tools to summarize and visualize a wealth of features of the clustering results. In addition, to ensure its convenience of use, flowClust has been adapted for the current FCM data format, and integrated with existing Bioconductor packages dedicated to FCM analysis. Conclusion flowClust addresses the issue of a dearth of software that helps automate FCM analysis with a sound theoretical foundation. It tends to give reproducible results, and helps reduce the significant subjectivity and human time cost encountered in FCM analysis. The package contributes to the cytometry community by offering an efficient, automated analysis platform which facilitates the active, ongoing technological advancement.

  8. Three-Dimensional Changes in the Midface Following Malar Calcium Hydroxyapatite Injection in a Cadaver Model.

    Science.gov (United States)

    Gatherwright, James R; Brown, Matthew S; Katira, Kristopher M; Rowe, David J

    2015-08-01

    Three-dimensional (3D) changes in the midface following malar calcium hydroxyapatite (CaHa) injection have not been systematically analyzed. The authors analyzed 3D volume changes in midface and naso-labial fold (NLF) volume, as well as lateral movement in the NLF/naso-labial crease (NLC) junction following malar injection of CaHa in a cadaver model. A single surgeon injected CaHa in the supraperiosteal plane. Sequential images were obtained with the VECTRA 3D system pre- and post-1.5- and 3-cc CaHa injections. All measurements were performed by a single examiner. Injection location was verified anatomically. Injections were performed in 16 fresh cadaver hemi-faces. Maximal increases in projection were centered on the malar injection site, with associated decreases in projection and volume in the infero-medial locations. Relative mean increases in volume of 3.16 cc and 4.94 cc were observed following the 1.5-cc and 3-cc injections, respectively. There was a relative decrease in the volume of the NLF of -0.3 cc and -0.4 cc following the 1.5- and 3-cc injections, respectively. Injection of CaHa was associated with lateral movements of the NLF-NLC junction at the level of the nasal sill, philtral columns, and oral commissure, measuring 2.7, 2.5, and 1.9 mm and 2.8, 2.9, and 2.4 mm following the 1.5- and 3-cc injections, respectively. Anatomical dissection verified the location in the supraperiosteal space and within the middle malar fat pad. Following malar CaHa injection, 3D photographic analysis showed a measureable lifting effect with recruitment of ptotic tissue and lateral movement of the NLF-NLC junction in a cadaver model. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  9. Investigation into Generation of Micro Features by Localised Electrochemical Deposition

    Science.gov (United States)

    Debnath, Subhrajit; Laskar, Hanimur Rahaman; Bhattacharyya, B.

    2017-11-01

    With the fast advancement of technology, localised electrochemical deposition (LECD) is becoming very advantageous in generating high aspect ratio micro features to meet the steep demand in modern precision industries of the present world. Except many other advantages, this technology is highly uncomplicated and economical for fabricating metal micro-parts with in micron ranges. In the present study, copper micro-columns have been fabricated utilizing LECD process. Different process parameters such as voltage, frequency, duty ratio and electrolyte concentration, which affect the deposition performance have been identified and their effects on deposition performances such as deposition rate, height and diameter of the micro-columns have been experimentally investigated. Taguchi's methodology has been used to study the effects as well as to obtain the optimum values of process parameters so that localised deposition with best performance can be achieved. Moreover, the generated micro-columns were carefully observed under optical and scanning electron microscope from where the surface quality of the deposited micro-columns has been studied qualitatively. Also, an array of copper micro-columns has been fabricated on stainless steel (SS-304) substrate for further exploration of LECD process capability.

  10. Comparison of ablation centration after bilateral sequential versus simultaneous LASIK.

    Science.gov (United States)

    Lin, Jane-Ming; Tsai, Yi-Yu

    2005-01-01

    To compare ablation centration after bilateral sequential and simultaneous myopic LASIK. A retrospective randomized case series was performed of 670 eyes of 335 consecutive patients who had undergone either bilateral sequential (group 1) or simultaneous (group 2) myopic LASIK between July 2000 and July 2001 at the China Medical University Hospital, Taichung, Taiwan. The ablation centrations of the first and second eyes in the two groups were compared 3 months postoperatively. Of 670 eyes, 274 eyes (137 patients) comprised the sequential group and 396 eyes (198 patients) comprised the simultaneous group. Three months post-operatively, 220 eyes of 110 patients (80%) in the sequential group and 236 eyes of 118 patients (60%) in the simultaneous group provided topographic data for centration analysis. For the first eyes, mean decentration was 0.39 +/- 0.26 mm in the sequential group and 0.41 +/- 0.19 mm in the simultaneous group (P = .30). For the second eyes, mean decentration was 0.28 +/- 0.23 mm in the sequential group and 0.30 +/- 0.21 mm in the simultaneous group (P = .36). Decentration in the second eyes significantly improved in both groups (group 1, P = .02; group 2, P sequential group and 0.32 +/- 0.18 mm in the simultaneous group (P = .33). The difference of ablation center angles between the first and second eyes was 43.2 sequential group and 45.1 +/- 50.8 degrees in the simultaneous group (P = .42). Simultaneous bilateral LASIK is comparable to sequential surgery in ablation centration.

  11. Final report of a scalable, automated, semipermanent seismic array (SASSA) method for detecting CO2 extent during geologic CO2 injection

    Energy Technology Data Exchange (ETDEWEB)

    Burnison, Shaughn [University of North Dakota Energy & Environmental Research Center, Grand Forks, ND (United States); Livers-Douglas, Amanda [University of North Dakota Energy & Environmental Research Center, Grand Forks, ND (United States); Barajas-Olalde, Cesar [University of North Dakota Energy & Environmental Research Center, Grand Forks, ND (United States); Jin, Lu [University of North Dakota Energy & Environmental Research Center, Grand Forks, ND (United States); Vettleson, Heidi [University of North Dakota Energy & Environmental Research Center, Grand Forks, ND (United States); Hamiling, John [University of North Dakota Energy & Environmental Research Center, Grand Forks, ND (United States); Gorecki, Charles [University of North Dakota Energy & Environmental Research Center, Grand Forks, ND (United States)

    2017-12-15

    The scalable, automated, semipermanent seismic array (SASSA) project led and managed by the Energy & Environmental Research Center (EERC) was designed as a 3-year proof-of-concept study to evaluate and demonstrate an innovative application of the seismic method. The concept was to use a sparse surface array of 96 nodal seismic sensors paired with a single, remotely operated active seismic source at a fixed location to monitor for CO2 saturation changes in a subsurface reservoir by processing the data for time-lapse changes at individual, strategically chosen reservoir reflection points. The combination of autonomous equipment and modern processing algorithms was used to apply the seismic method in a manner different from the normal paradigm of collecting a spatially dense data set to produce an image. It was used instead to monitor individual, strategically chosen reservoir reflection points for detectable signal character changes that could be attributed to the passing of a CO2 saturation front or, possibly, changes in reservoir pressure. Data collection occurred over the course of 1 year at an oil field undergoing CO2 injection for enhanced oil recovery (EOR) and focused on four overlapping “five-spot” EOR injector–producer patterns. Selection, procurement, configuration, installation, and testing of project equipment and collection of five baseline data sets were completed in advance of CO2 injection within the study area. Weekly remote data collection produced 41 incremental time-lapse records for each of the 96 nodes. Validation was provided by two methods: 1) a conventional 2-D seismic line acquired through the center of the study area before injection started and again after the project ended and processed in a time-lapse manner and 2) by CO2 saturation maps created from reservoir simulations based on injection and production history matching. Interpreted results were encouraging but mixed, with

  12. A Survey of Multi-Objective Sequential Decision-Making

    NARCIS (Netherlands)

    Roijers, D.M.; Vamplew, P.; Whiteson, S.; Dazeley, R.

    2013-01-01

    Sequential decision-making problems with multiple objectives arise naturally in practice and pose unique challenges for research in decision-theoretic planning and learning, which has largely focused on single-objective settings. This article surveys algorithms designed for sequential

  13. Automated crack detection in conductive smart-concrete structures using a resistor mesh model

    Science.gov (United States)

    Downey, Austin; D'Alessandro, Antonella; Ubertini, Filippo; Laflamme, Simon

    2018-03-01

    Various nondestructive evaluation techniques are currently used to automatically detect and monitor cracks in concrete infrastructure. However, these methods often lack the scalability and cost-effectiveness over large geometries. A solution is the use of self-sensing carbon-doped cementitious materials. These self-sensing materials are capable of providing a measurable change in electrical output that can be related to their damage state. Previous work by the authors showed that a resistor mesh model could be used to track damage in structural components fabricated from electrically conductive concrete, where damage was located through the identification of high resistance value resistors in a resistor mesh model. In this work, an automated damage detection strategy that works through placing high value resistors into the previously developed resistor mesh model using a sequential Monte Carlo method is introduced. Here, high value resistors are used to mimic the internal condition of damaged cementitious specimens. The proposed automated damage detection method is experimentally validated using a 500 × 500 × 50 mm3 reinforced cement paste plate doped with multi-walled carbon nanotubes exposed to 100 identical impact tests. Results demonstrate that the proposed Monte Carlo method is capable of detecting and localizing the most prominent damage in a structure, demonstrating that automated damage detection in smart-concrete structures is a promising strategy for real-time structural health monitoring of civil infrastructure.

  14. Sequential lineups: shift in criterion or decision strategy?

    Science.gov (United States)

    Gronlund, Scott D

    2004-04-01

    R. C. L. Lindsay and G. L. Wells (1985) argued that a sequential lineup enhanced discriminability because it elicited use of an absolute decision strategy. E. B. Ebbesen and H. D. Flowe (2002) argued that a sequential lineup led witnesses to adopt a more conservative response criterion, thereby affecting bias, not discriminability. Height was encoded as absolute (e.g., 6 ft [1.83 m] tall) or relative (e.g., taller than). If a sequential lineup elicited an absolute decision strategy, the principle of transfer-appropriate processing predicted that performance should be best when height was encoded absolutely. Conversely, if a simultaneous lineup elicited a relative decision strategy, performance should be best when height was encoded relatively. The predicted interaction was observed, providing direct evidence for the decision strategies explanation of what happens when witnesses view a sequential lineup.

  15. How to Read the Tractatus Sequentially

    Directory of Open Access Journals (Sweden)

    Tim Kraft

    2016-11-01

    Full Text Available One of the unconventional features of Wittgenstein’s Tractatus Logico-Philosophicus is its use of an elaborated and detailed numbering system. Recently, Bazzocchi, Hacker und Kuusela have argued that the numbering system means that the Tractatus must be read and interpreted not as a sequentially ordered book, but as a text with a two-dimensional, tree-like structure. Apart from being able to explain how the Tractatus was composed, the tree reading allegedly solves exegetical issues both on the local (e. g. how 4.02 fits into the series of remarks surrounding it and the global level (e. g. relation between ontology and picture theory, solipsism and the eye analogy, resolute and irresolute readings. This paper defends the sequential reading against the tree reading. After presenting the challenges generated by the numbering system and the two accounts as attempts to solve them, it is argued that Wittgenstein’s own explanation of the numbering system, anaphoric references within the Tractatus and the exegetical issues mentioned above do not favour the tree reading, but a version of the sequential reading. This reading maintains that the remarks of the Tractatus form a sequential chain: The role of the numbers is to indicate how remarks on different levels are interconnected to form a concise, surveyable and unified whole.

  16. Long-term monitoring of soil gas fluxes with closed chambers using automated and manual systems

    Energy Technology Data Exchange (ETDEWEB)

    Scott, A.; Crichton, I.; Ball, B.C.

    1999-10-01

    The authors describe two gas sample collection techniques, each of which is used in conjunction with custom made automated or manually operated closed chambers. The automated system allows automatic collection of gas samples for simultaneous analysis of multiple trace gas efflux from soils, permitting long-term monitoring. Since the manual system is cheaper to produce, it can be replicated more than the automated and used to estimate spatial variability of soil fluxes. The automated chamber covers a soil area of 0.5 m{sup 2} and has a motor driven lid that remains operational throughout a range of weather conditions. Both systems use gas-tight containers of robust metal construction, which give good sample retention, thereby allowing long-term storage and convenience of transport from remote locations. The containers in the automated system are filled by pumping gas from the closed chamber via a multiway rotary valve. Stored samples from both systems are analyzed simultaneously for N{sub 2}O and CO{sub 2} using automated injection into laboratory-based gas chromatographs. The use of both collection systems is illustrated by results from a field experiment on sewage sludge disposal to land where N{sub 2}O fluxes were high. The automated gas sampling system permitted quantification of the marked temporal variability of concurrent N{sub 2}O and CO{sub 2} fluxes and allowed improved estimation of cumulative fluxes. The automated measurement approach yielded higher estimates of cumulative flux because integration of manual point-in-time observations missed a number of transient high-flux events.

  17. Autonomy and Automation

    Science.gov (United States)

    Shively, Jay

    2017-01-01

    A significant level of debate and confusion has surrounded the meaning of the terms autonomy and automation. Automation is a multi-dimensional concept, and we propose that Remotely Piloted Aircraft Systems (RPAS) automation should be described with reference to the specific system and task that has been automated, the context in which the automation functions, and other relevant dimensions. In this paper, we present definitions of automation, pilot in the loop, pilot on the loop and pilot out of the loop. We further propose that in future, the International Civil Aviation Organization (ICAO) RPAS Panel avoids the use of the terms autonomy and autonomous when referring to automated systems on board RPA. Work Group 7 proposes to develop, in consultation with other workgroups, a taxonomy of Levels of Automation for RPAS.

  18. High-throughput flow injection analysis mass spectroscopy with networked delivery of color-rendered results. 2. Three-dimensional spectral mapping of 96-well combinatorial chemistry racks.

    Science.gov (United States)

    Görlach, E; Richmond, R; Lewis, I

    1998-08-01

    For the last two years, the mass spectroscopy section of the Novartis Pharma Research Core Technology group has analyzed tens of thousands of multiple parallel synthesis samples from the Novartis Pharma Combinatorial Chemistry program, using an in-house developed automated high-throughput flow injection analysis electrospray ionization mass spectroscopy system. The electrospray spectra of these samples reflect the many structures present after the cleavage step from the solid support. The overall success of the sequential synthesis is mirrored in the purity of the expected end product, but the partial success of individual synthesis steps is evident in the impurities in the mass spectrum. However this latter reaction information, which is of considerable utility to the combinatorial chemist, is effectively hidden from view by the very large number of analyzed samples. This information is now revealed at the workbench of the combinatorial chemist by a novel three-dimensional display of each rack's complete mass spectral ion current using the in-house RackViewer Visual Basic application. Colorization of "forbidden loss" and "forbidden gas-adduct" zones, normalization to expected monoisotopic molecular weight, colorization of ionization intensity, and sorting by row or column were used in combination to highlight systematic patterns in the mass spectroscopy data.

  19. An environmental disinfection odyssey: evaluation of sequential interventions to improve disinfection of Clostridium difficile isolation rooms.

    Science.gov (United States)

    Sitzlar, Brett; Deshpande, Abhishek; Fertelli, Dennis; Kundrapu, Sirisha; Sethi, Ajay K; Donskey, Curtis J

    2013-05-01

    OBJECTIVE. Effective disinfection of hospital rooms after discharge of patients with Clostridium difficile infection (CDI) is necessary to prevent transmission. We evaluated the impact of sequential cleaning and disinfection interventions by culturing high-touch surfaces in CDI rooms after cleaning. DESIGN. Prospective intervention. SETTING. A Veterans Affairs hospital. INTERVENTIONS. During a 21-month period, 3 sequential tiered interventions were implemented: (1) fluorescent markers to provide monitoring and feedback on thoroughness of cleaning facility-wide, (2) addition of an automated ultraviolet radiation device for adjunctive disinfection of CDI rooms, and (3) enhanced standard disinfection of CDI rooms, including a dedicated daily disinfection team and implementation of a process requiring supervisory assessment and clearance of terminally cleaned CDI rooms. To determine the impact of the interventions, cultures were obtained from CDI rooms after cleaning and disinfection. RESULTS. The fluorescent marker intervention improved the thoroughness of cleaning of high-touch surfaces (from 47% to 81% marker removal; P disinfection, whereas during interventions periods 1, 2, and 3 the percentages of CDI rooms with positive cultures after disinfection were reduced to 57%, 35%, and 7%, respectively. CONCLUSIONS. An intervention that included formation of a dedicated daily disinfection team and implementation of a standardized process for clearing CDI rooms achieved consistent CDI room disinfection. Culturing of CDI rooms provides a valuable tool to drive improvements in environmental disinfection.

  20. A minimax procedure in the context of sequential mastery testing

    NARCIS (Netherlands)

    Vos, Hendrik J.

    1999-01-01

    The purpose of this paper is to derive optimal rules for sequential mastery tests. In a sequential mastery test, the decision is to classify a subject as a master or a nonmaster, or to continue sampling and administering another random test item. The framework of minimax sequential decision theory

  1. In search of an improved injection technique for the clinical application of spermatogonial stem cell transplantation.

    Science.gov (United States)

    Faes, Katrien; Lahoutte, Tony; Hoorens, Anne; Tournaye, Herman; Goossens, Ellen

    2017-03-01

    When fertility is impaired by anticancer treatment, spermatogonial stem cell transplantation (SSCT) could be used as a fertility restoration technique later on in life. Previously, we have demonstrated that a testicular cell suspension could be injected into a human cadaver testis, however, leakage to the interstitium was observed. In this study, injection of mouse testicular cells at an injection height of 50 cm (hydrostatic pressure) or via an automated injection pump (1400 µl, 2600 µl and 3000 µl) was evaluated. Significant difference in the filled radioactive volume was reached between the group in which 1400 µl was injected with an infusion pump and the groups in which 2600 µl (P = 0.019) or 3000 µl (P = 0.010) was injected. In all experimental groups green fluorescent protein positive (GFP + ) cells were observed in the seminiferous tubules. In conclusion, a lower injection height did not resolve the leakage of the injected cells to the interstitium. Using the infusion pump resulted in more efficient filling of the seminiferous tubules with lower interexperimental variability. Although leakage to the interstitium was still observed, with further optimisation, the use of an infusion pump for clinical application is advantageous. Copyright © 2016 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.

  2. Multichannel, sequential or combined X-ray spectrometry

    International Nuclear Information System (INIS)

    Florestan, J.

    1979-01-01

    X-ray spectrometer qualities and defects are evaluated for sequential and multichannel categories. Multichannel X-ray spectrometer has time-coherency advantage and its results could be more reproducible; on the other hand some spatial incoherency limits low percentage and traces applications, specially when backgrounds are very variable. In this last case, sequential X-ray spectrometer would find again great usefulness [fr

  3. Design and development of the helicity injection system in Versatile Experiment Spherical Torus

    International Nuclear Information System (INIS)

    Park, JongYoon; An, Younghwa; Jung, Bongki; Lee, Jeongwon; Lee, HyunYoung; Chung, Kyoung-Jae; Na, Yong-Su; Hwang, Y.S.

    2015-01-01

    Graphical abstract: - Highlights: • A high current electron gun with single pulse power for both arc and extraction is developed. • The optimal gun operation is confirmed by impedance matching between the PFN and plasma. • The gun injected currents of 0.95 kA with the voltage of ∼410 V for 5 ms with a 1.2 kV PFN. • The helicity injection system using the gun has been developed and tested successfully in VEST. • Toroidal currents of up to 3.8 kA confirm possible relaxation into tokamak-like plasma. - Abstract: A helicity injection system for the Versatile Experiment Spherical Torus (VEST) has been successfully developed and commissioned. A high current electron gun utilizing hollow cathode and washer stacks has been designed and constructed with a single pulse power system that can provide voltages for both arc discharge and extraction sequentially. Tests for electron gun operation with the single pulse power system have been conducted under various toroidal and poloidal field strengths. The estimated plasma impedance, depending on the injection magnetic field structure, can be utilized for the optimal gun operation by impedance matching between the pulse power system and plasma. With the charging voltage of 1.2 kV, injection current of 0.95 kA has been obtained with the injection voltage of 410 V for about 5 ms. Initial helicity injection experiments have been conducted under various toroidal and poloidal field strengths and a toroidal plasma current of up to 3.8 kA is observed with the current multiplication larger than the geometric stacking ratio, confirming the possibility of relaxation into tokamak-like plasma with closed flux formation.

  4. Design and development of the helicity injection system in Versatile Experiment Spherical Torus

    Energy Technology Data Exchange (ETDEWEB)

    Park, JongYoon; An, Younghwa; Jung, Bongki; Lee, Jeongwon; Lee, HyunYoung; Chung, Kyoung-Jae; Na, Yong-Su; Hwang, Y.S., E-mail: yhwang@snu.ac.kr

    2015-10-15

    Graphical abstract: - Highlights: • A high current electron gun with single pulse power for both arc and extraction is developed. • The optimal gun operation is confirmed by impedance matching between the PFN and plasma. • The gun injected currents of 0.95 kA with the voltage of ∼410 V for 5 ms with a 1.2 kV PFN. • The helicity injection system using the gun has been developed and tested successfully in VEST. • Toroidal currents of up to 3.8 kA confirm possible relaxation into tokamak-like plasma. - Abstract: A helicity injection system for the Versatile Experiment Spherical Torus (VEST) has been successfully developed and commissioned. A high current electron gun utilizing hollow cathode and washer stacks has been designed and constructed with a single pulse power system that can provide voltages for both arc discharge and extraction sequentially. Tests for electron gun operation with the single pulse power system have been conducted under various toroidal and poloidal field strengths. The estimated plasma impedance, depending on the injection magnetic field structure, can be utilized for the optimal gun operation by impedance matching between the pulse power system and plasma. With the charging voltage of 1.2 kV, injection current of 0.95 kA has been obtained with the injection voltage of 410 V for about 5 ms. Initial helicity injection experiments have been conducted under various toroidal and poloidal field strengths and a toroidal plasma current of up to 3.8 kA is observed with the current multiplication larger than the geometric stacking ratio, confirming the possibility of relaxation into tokamak-like plasma with closed flux formation.

  5. Induction of simultaneous and sequential malolactic fermentation in durian wine.

    Science.gov (United States)

    Taniasuri, Fransisca; Lee, Pin-Rou; Liu, Shao-Quan

    2016-08-02

    This study represented for the first time the impact of malolactic fermentation (MLF) induced by Oenococcus oeni and its inoculation strategies (simultaneous vs. sequential) on the fermentation performance as well as aroma compound profile of durian wine. There was no negative impact of simultaneous inoculation of O. oeni and Saccharomyces cerevisiae on the growth and fermentation kinetics of S. cerevisiae as compared to sequential fermentation. Simultaneous MLF did not lead to an excessive increase in volatile acidity as compared to sequential MLF. The kinetic changes of organic acids (i.e. malic, lactic, succinic, acetic and α-ketoglutaric acids) varied with simultaneous and sequential MLF relative to yeast alone. MLF, regardless of inoculation mode, resulted in higher production of fermentation-derived volatiles as compared to control (alcoholic fermentation only), including esters, volatile fatty acids, and terpenes, except for higher alcohols. Most indigenous volatile sulphur compounds in durian were decreased to trace levels with little differences among the control, simultaneous and sequential MLF. Among the different wines, the wine with simultaneous MLF had higher concentrations of terpenes and acetate esters while sequential MLF had increased concentrations of medium- and long-chain ethyl esters. Relative to alcoholic fermentation only, both simultaneous and sequential MLF reduced acetaldehyde substantially with sequential MLF being more effective. These findings illustrate that MLF is an effective and novel way of modulating the volatile and aroma compound profile of durian wine. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Sequential Banking.

    OpenAIRE

    Bizer, David S; DeMarzo, Peter M

    1992-01-01

    The authors study environments in which agents may borrow sequentially from more than one leader. Although debt is prioritized, additional lending imposes an externality on prior debt because, with moral hazard, the probability of repayment of prior loans decreases. Equilibrium interest rates are higher than they would be if borrowers could commit to borrow from at most one bank. Even though the loan terms are less favorable than they would be under commitment, the indebtedness of borrowers i...

  7. The light spot test: Measuring anxiety in mice in an automated home-cage environment.

    Science.gov (United States)

    Aarts, Emmeke; Maroteaux, Gregoire; Loos, Maarten; Koopmans, Bastijn; Kovačević, Jovana; Smit, August B; Verhage, Matthijs; Sluis, Sophie van der

    2015-11-01

    Behavioral tests of animals in a controlled experimental setting provide a valuable tool to advance understanding of genotype-phenotype relations, and to study the effects of genetic and environmental manipulations. To optimally benefit from the increasing numbers of genetically engineered mice, reliable high-throughput methods for comprehensive behavioral phenotyping of mice lines have become a necessity. Here, we describe the development and validation of an anxiety test, the light spot test, that allows for unsupervised, automated, high-throughput testing of mice in a home-cage system. This automated behavioral test circumvents bias introduced by pretest handling, and enables recording both baseline behavior and the behavioral test response over a prolonged period of time. We demonstrate that the light spot test induces a behavioral response in C57BL/6J mice. This behavior reverts to baseline when the aversive stimulus is switched off, and is blunted by treatment with the anxiolytic drug Diazepam, demonstrating predictive validity of the assay, and indicating that the observed behavioral response has a significant anxiety component. Also, we investigated the effectiveness of the light spot test as part of sequential testing for different behavioral aspects in the home-cage. Two learning tests, administered prior to the light spot test, affected the light spot test parameters. The light spot test is a novel, automated assay for anxiety-related high-throughput testing of mice in an automated home-cage environment, allowing for both comprehensive behavioral phenotyping of mice, and rapid screening of pharmacological compounds. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Equivalence between quantum simultaneous games and quantum sequential games

    OpenAIRE

    Kobayashi, Naoki

    2007-01-01

    A framework for discussing relationships between different types of games is proposed. Within the framework, quantum simultaneous games, finite quantum simultaneous games, quantum sequential games, and finite quantum sequential games are defined. In addition, a notion of equivalence between two games is defined. Finally, the following three theorems are shown: (1) For any quantum simultaneous game G, there exists a quantum sequential game equivalent to G. (2) For any finite quantum simultaneo...

  9. Accounting for Heterogeneous Returns in Sequential Schooling Decisions

    NARCIS (Netherlands)

    Zamarro, G.

    2006-01-01

    This paper presents a method for estimating returns to schooling that takes into account that returns may be heterogeneous among agents and that educational decisions are made sequentially.A sequential decision model is interesting because it explicitly considers that the level of education of each

  10. Simultaneous Versus Sequential Ptosis and Strabismus Surgery in Children.

    Science.gov (United States)

    Revere, Karen E; Binenbaum, Gil; Li, Jonathan; Mills, Monte D; Katowitz, William R; Katowitz, James A

    The authors sought to compare the clinical outcomes of simultaneous versus sequential ptosis and strabismus surgery in children. Retrospective, single-center cohort study of children requiring both ptosis and strabismus surgery on the same eye. Simultaneous surgeries were performed during a single anesthetic event; sequential surgeries were performed at least 7 weeks apart. Outcomes were ptosis surgery success (margin reflex distance 1 ≥ 2 mm, good eyelid contour, and good eyelid crease); strabismus surgery success (ocular alignment within 10 prism diopters of orthophoria and/or improved head position); surgical complications; and reoperations. Fifty-six children were studied, 38 had simultaneous surgery and 18 sequential. Strabismus surgery was performed first in 38/38 simultaneous and 6/18 sequential cases. Mean age at first surgery was 64 months, with mean follow up 27 months. A total of 75% of children had congenital ptosis; 64% had comitant strabismus. A majority of ptosis surgeries were frontalis sling (59%) or Fasanella-Servat (30%) procedures. There were no significant differences between simultaneous and sequential groups with regards to surgical success rates, complications, or reoperations (all p > 0.28). In the first comparative study of simultaneous versus sequential ptosis and strabismus surgery, no advantage for sequential surgery was seen. Despite a theoretical risk of postoperative eyelid malposition or complications when surgeries were performed in a combined manner, the rate of such outcomes was not increased with simultaneous surgeries. Performing ptosis and strabismus surgery together appears to be clinically effective and safe, and reduces anesthesia exposure during childhood.

  11. Forced Sequence Sequential Decoding

    DEFF Research Database (Denmark)

    Jensen, Ole Riis

    In this thesis we describe a new concatenated decoding scheme based on iterations between an inner sequentially decoded convolutional code of rate R=1/4 and memory M=23, and block interleaved outer Reed-Solomon codes with non-uniform profile. With this scheme decoding with good performance...... is possible as low as Eb/No=0.6 dB, which is about 1.7 dB below the signal-to-noise ratio that marks the cut-off rate for the convolutional code. This is possible since the iteration process provides the sequential decoders with side information that allows a smaller average load and minimizes the probability...... of computational overflow. Analytical results for the probability that the first Reed-Solomon word is decoded after C computations are presented. This is supported by simulation results that are also extended to other parameters....

  12. Analyse de code et processus d'évaluation des composants sécurisés contre l'injection de faute

    OpenAIRE

    Dureuil , Louis

    2016-01-01

    Vulnerability detections for smart cards require state of the art methods both to attack and to protect the secure device. A typical type of attack is fault injection, most notably performed by means of laser techniques. To prevent some of the consequences of this kind of attacks, several analyses are conducted at the software level. Being able to define criteria and to propose automated tools that can survey the robustness of an application to fault injection is thus nowadays a hot topic, ev...

  13. Validation of a fully automated robotic setup for preparation of whole blood samples for LC-MS toxicology analysis

    DEFF Research Database (Denmark)

    Andersen, David Wederkinck; Rasmussen, Brian; Linnet, Kristian

    2012-01-01

    A fully automated setup was developed for preparing whole blood samples using a Tecan Evo workstation. By integrating several add-ons to the robotic platform, the flexible setup was able to prepare samples from sample tubes to a 96-well sample plate ready for injection on liquid chromatography...

  14. Reading Remediation Based on Sequential and Simultaneous Processing.

    Science.gov (United States)

    Gunnison, Judy; And Others

    1982-01-01

    The theory postulating a dichotomy between sequential and simultaneous processing is reviewed and its implications for remediating reading problems are reviewed. Research is cited on sequential-simultaneous processing for early and advanced reading. A list of remedial strategies based on the processing dichotomy addresses decoding and lexical…

  15. AUTOMATION OF IMAGE DATA PROCESSING

    Directory of Open Access Journals (Sweden)

    Preuss Ryszard

    2014-12-01

    Full Text Available This article discusses the current capabilities of automate processing of the image data on the example of using PhotoScan software by Agisoft . At present, image data obtained by various registration systems (metric and non - metric cameras placed on airplanes , satellites , or more often on UAVs is used to create photogrammetric products. Multiple registrations of object or land area (large groups of photos are captured are usually performed in order to eliminate obscured area as well as to raise the final accuracy of the photogrammetric product. Because of such a situation t he geometry of the resulting image blocks is far from the typical configuration of images . For fast images georeferencing automatic image matching algorithms are currently applied . They can create a model of a block in the local coordinate system or using initial exterior orientation and measured control points can provide image georeference in an external reference frame. In the case of non - metric image application, it is also possible to carry out self - calibration process at this stage . Image matching algorithm is also used in generation of dense point clouds reconstructing spatial shape of the object ( area. In subsequent processing steps it is possible to obtain typical photogrammetric products such as orthomosaic , DSM or DTM and a photorealistic solid model of an object . All aforementioned processing steps are implemented in a single program in contrary to standard commercial software dividing all steps into dedicated modules . I mage processing leading to final geo referenced products can be fully automated including sequential implementation of the processing steps at predetermined control parameters . The paper presents the practical results of the application fully automatic generation of othomosaic for both images obtained by a metric Vexell camera and a block of images acquired by a non - metric UAV system.

  16. Four-channel surface coil array for sequential CW-EPR image acquisition

    Science.gov (United States)

    Enomoto, Ayano; Emoto, Miho; Fujii, Hirotada; Hirata, Hiroshi

    2013-09-01

    This article describes a four-channel surface coil array to increase the area of visualization for continuous-wave electron paramagnetic resonance (CW-EPR) imaging. A 776-MHz surface coil array was constructed with four independent surface coil resonators and three kinds of switches. Control circuits for switching the resonators were also built to sequentially perform EPR image acquisition for each resonator. The resonance frequencies of the resonators were shifted using PIN diode switches to decouple the inductively coupled coils. To investigate the area of visualization with the surface coil array, three-dimensional EPR imaging was performed using a glass cell phantom filled with a solution of nitroxyl radicals. The area of visualization obtained with the surface coil array was increased approximately 3.5-fold in comparison to that with a single surface coil resonator. Furthermore, to demonstrate the applicability of this surface coil array to animal imaging, three-dimensional EPR imaging was performed in a living mouse with an exogenously injected nitroxyl radical imaging agent.

  17. Electrically evoked compound action potentials artefact rejection by independent component analysis: procedure automation.

    Science.gov (United States)

    Akhoun, Idrick; McKay, Colette; El-Deredy, Wael

    2015-01-15

    Independent-components-analysis (ICA) successfully separated electrically-evoked compound action potentials (ECAPs) from the stimulation artefact and noise (ECAP-ICA, Akhoun et al., 2013). This paper shows how to automate the ECAP-ICA artefact cancellation process. Raw-ECAPs without artefact rejection were consecutively recorded for each stimulation condition from at least 8 intra-cochlear electrodes. Firstly, amplifier-saturated recordings were discarded, and the data from different stimulus conditions (different current-levels) were concatenated temporally. The key aspect of the automation procedure was the sequential deductive source categorisation after ICA was applied with a restriction to 4 sources. The stereotypical aspect of the 4 sources enables their automatic classification as two artefact components, a noise and the sought ECAP based on theoretical and empirical considerations. The automatic procedure was tested using 8 cochlear implant (CI) users and one to four stimulus electrodes. The artefact and noise sources were successively identified and discarded, leaving the ECAP as the remaining source. The automated ECAP-ICA procedure successfully extracted the correct ECAPs compared to standard clinical forward masking paradigm in 22 out of 26 cases. ECAP-ICA does not require extracting the ECAP from a combination of distinct buffers as it is the case with regular methods. It is an alternative that does not have the possible bias of traditional artefact rejections such as alternate-polarity or forward-masking paradigms. The ECAP-ICA procedure bears clinical relevance, for example as the artefact rejection sub-module of automated ECAP-threshold detection techniques, which are common features of CI clinical fitting software. Copyright © 2014. Published by Elsevier B.V.

  18. Fully automated chest wall line segmentation in breast MRI by using context information

    Science.gov (United States)

    Wu, Shandong; Weinstein, Susan P.; Conant, Emily F.; Localio, A. Russell; Schnall, Mitchell D.; Kontos, Despina

    2012-03-01

    Breast MRI has emerged as an effective modality for the clinical management of breast cancer. Evidence suggests that computer-aided applications can further improve the diagnostic accuracy of breast MRI. A critical and challenging first step for automated breast MRI analysis, is to separate the breast as an organ from the chest wall. Manual segmentation or user-assisted interactive tools are inefficient, tedious, and error-prone, which is prohibitively impractical for processing large amounts of data from clinical trials. To address this challenge, we developed a fully automated and robust computerized segmentation method that intensively utilizes context information of breast MR imaging and the breast tissue's morphological characteristics to accurately delineate the breast and chest wall boundary. A critical component is the joint application of anisotropic diffusion and bilateral image filtering to enhance the edge that corresponds to the chest wall line (CWL) and to reduce the effect of adjacent non-CWL tissues. A CWL voting algorithm is proposed based on CWL candidates yielded from multiple sequential MRI slices, in which a CWL representative is generated and used through a dynamic time warping (DTW) algorithm to filter out inferior candidates, leaving the optimal one. Our method is validated by a representative dataset of 20 3D unilateral breast MRI scans that span the full range of the American College of Radiology (ACR) Breast Imaging Reporting and Data System (BI-RADS) fibroglandular density categorization. A promising performance (average overlay percentage of 89.33%) is observed when the automated segmentation is compared to manually segmented ground truth obtained by an experienced breast imaging radiologist. The automated method runs time-efficiently at ~3 minutes for each breast MR image set (28 slices).

  19. Automating quantum dot barcode assays using microfluidics and magnetism for the development of a point-of-care device.

    Science.gov (United States)

    Gao, Yali; Lam, Albert W Y; Chan, Warren C W

    2013-04-24

    The impact of detecting multiple infectious diseases simultaneously at point-of-care with good sensitivity, specificity, and reproducibility would be enormous for containing the spread of diseases in both resource-limited and rich countries. Many barcoding technologies have been introduced for addressing this need as barcodes can be applied to detecting thousands of genetic and protein biomarkers simultaneously. However, the assay process is not automated and is tedious and requires skilled technicians. Barcoding technology is currently limited to use in resource-rich settings. Here we used magnetism and microfluidics technology to automate the multiple steps in a quantum dot barcode assay. The quantum dot-barcoded microbeads are sequentially (a) introduced into the chip, (b) magnetically moved to a stream containing target molecules, (c) moved back to the original stream containing secondary probes, (d) washed, and (e) finally aligned for detection. The assay requires 20 min, has a limit of detection of 1.2 nM, and can detect genetic targets for HIV, hepatitis B, and syphilis. This study provides a simple strategy to automate the entire barcode assay process and moves barcoding technologies one step closer to point-of-care applications.

  20. Interpretation of erythrocyte histograms obtained from automated hematology analyzers in hematologic diseases

    Directory of Open Access Journals (Sweden)

    Ali Maleki

    2015-12-01

    Full Text Available Background: Presently, the graphical data of blood cells (histograms and cytograms or/ scattergrams that they are usually available in all modern automated hematology analyzers are an integral a part of automated complete blood count (CBC. To find incorrect results from automated hematology analyzer and establish the samples that require additional analysis, Laboratory employees will use those data for quality control of obtaining results, to assist identification of complex and troublesome cases. Methods: During this descriptive analytic study, in addition to erythrocyte graphs from variety of patients, referring from March 2013 to Feb 2014 to our clinical laboratory, Zagros Hospital, Kermanshah, Iran, are given, the papers published in relevant literature as well as available published manuals of automatic blood cell counters were used. articles related to the key words of erythrocyte graphs and relevant literature as well as available published manuals of automatic blood cell counters were searched from valid databases such as Springer Link, google scholar, Pubmed and Sciencedirect. Then, the articles related to erythrogram, erythrocyte histogram and hematology analyzer graphs are involved in diagnosis of hematological disorder were searched and selected for this study. Results: Histograms and different automated CBC parameter become abnormal in various pathologic conditions, and can present important clues for diagnosis and treatment of hematologic and non-hematologic disorders. In several instances, these histograms have characteristic appearances in an exceedingly wide range of pathological conditions. In some hematologic disorders like iron deficiency or megaloblastic anemia, a sequential histogram can clearly show the progressive treatment and management. Conclusion: These graphical data are often accompanied by other automated CBC parameter and microscopic examination of peripheral blood smears (PBS, and can help in monitoring and

  1. Home Automation

    OpenAIRE

    Ahmed, Zeeshan

    2010-01-01

    In this paper I briefly discuss the importance of home automation system. Going in to the details I briefly present a real time designed and implemented software and hardware oriented house automation research project, capable of automating house's electricity and providing a security system to detect the presence of unexpected behavior.

  2. Large scale gas injection test (Lasgit): Results from two gas injection tests

    International Nuclear Information System (INIS)

    Cuss, R. J.; Harrington, J. F.; Noy, D. J.; Wikman, A.; Sellin, P.

    2011-01-01

    This paper describes the initial results from a large scale gas injection test (Lasgit) performed at the Aespoe Hard Rock Laboratory (Sweden)). Lasgit is a full-scale field-scale experiment based on the Swedish KBS-3V repository concept, examining the processes controlling gas and water flow in compact buffer bentonite. The first 2 years of the test focused on the artificial hydration of the bentonite buffer. This was followed by a programme of hydraulic and gas injection tests which ran from day 843 to 1110. A further period of artificial hydration occurred from day 1110 to 1385, followed by a more complex programme of gas injection testing which remains on going (day 1385+). After 2 years of hydration, hydraulic conductivity and specific storage values in the lower filter array were found to range from 9 x 10 -14 to 1.6 x 10 -13 m/s and 5.5 x 10 -5 to 4.4 x 10 -4 m -1 respectively, with the injection filter FL903 yielding values of 7.5 x 10 -14 m/s and 2.5 x 10 -5 m -1 . A second set of hydraulic measurements were performed over 1 year and a half later yielding similar values, in the range 7.8 x 10 -14 m/s and 1.3 x 10 -13 m/s. The hydraulic conductivity of FL903 had reduced slightly to 5.3 x 10 -14 m/s while specific storage had increased to 4.0 x 10 -5 m -1 . Both datasets agree with laboratory values performed on small-scale saturated samples. Two sets of gas injection tests were performed over a 3 year period. During the course of testing, gas entry pressure was found to increase from around 650 kPa to approximately 1.3 MPa, indicative of the maturation of the clay. The sequential reduction in volumetric flow rate and lack of correlation between the rate of gas inflow and the gas pressure gradient observed during constant pressure steps prior to major gas entry, is suggestive of a reduction in gas permeability of the buffer and indicates only limited quantities of gas can be injected into the clay without interacting with the continuum stress field. Major gas

  3. Simple automated preparation of O-[{sup 11}C]methyl-L-tyrosine for routine clinical use

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, Yoichi [CYRIC Tohoku University, Aramaki, Aoba-ku, Sendai 980-8578 (Japan); Iwata, Ren [CYRIC Tohoku University, Aramaki, Aoba-ku, Sendai 980-8578 (Japan)]. E-mail: rencyric@cyric.tohoku.ac.jp; Furumoto, Shozo [TUBERO, Tohoku University, Sendai 980-8575 (Japan); Pascali, Claudio [National Cancer Institute, 20133 Milan (Italy); Bogni, Anna [National Cancer Institute, 20133 Milan (Italy); Kubota, Kazuo [International Medical Center, Tokyo 162-8655 (Japan); Ishiwata, Kiichi [Tokyo Metropolitan Institute of Gerontology, Tokyo 173-0022 (Japan)

    2005-07-01

    The previously reported preparation of O-[{sup 11}C]methyl-L-tyrosine ([{sup 11}C]MT), a promising tumor imaging agent, has been now considerably simplified and automated. Main changes were the use of [{sup 11}C]methyl iodide ([{sup 11}C]MeI) in the reaction with L-tyrosine disodium and the use of solid phase extraction on commercially available cartridges instead of HPLC for the final purification. An injectable saline solution of [{sup 11}C]MT was obtained within 30 min after EOB with radiochemical yield of ca. 60% (decay-corrected, based on [{sup 11}C]MeI). Radiochemical purity was over 97%. The automated preparation was carried out using a miniature module employing manifold valves.

  4. Optimization of automation: I. Estimation method of cognitive automation rates reflecting the effects of automation on human operators in nuclear power plants

    International Nuclear Information System (INIS)

    Lee, Seung Min; Kim, Jong Hyun; Seong, Poong Hyun

    2014-01-01

    Highlights: • We propose an estimation method of the automation rate by taking the advantages of automation as the estimation measures. • We conduct the experiments to examine the validity of the suggested method. • The higher the cognitive automation rate is, the greater the decreased rate of the working time will be. • The usefulness of the suggested estimation method is proved by statistical analyses. - Abstract: Since automation was introduced in various industrial fields, the concept of the automation rate has been used to indicate the inclusion proportion of automation among all work processes or facilities. Expressions of the inclusion proportion of automation are predictable, as is the ability to express the degree of the enhancement of human performance. However, many researchers have found that a high automation rate does not guarantee high performance. Therefore, to reflect the effects of automation on human performance, this paper proposes a new estimation method of the automation rate that considers the effects of automation on human operators in nuclear power plants (NPPs). Automation in NPPs can be divided into two types: system automation and cognitive automation. Some general descriptions and characteristics of each type of automation are provided, and the advantages of automation are investigated. The advantages of each type of automation are used as measures of the estimation method of the automation rate. One advantage was found to be a reduction in the number of tasks, and another was a reduction in human cognitive task loads. The system and the cognitive automation rate were proposed as quantitative measures by taking advantage of the aforementioned benefits. To quantify the required human cognitive task loads and thus suggest the cognitive automation rate, Conant’s information-theory-based model was applied. The validity of the suggested method, especially as regards the cognitive automation rate, was proven by conducting

  5. C-quence: a tool for analyzing qualitative sequential data.

    Science.gov (United States)

    Duncan, Starkey; Collier, Nicholson T

    2002-02-01

    C-quence is a software application that matches sequential patterns of qualitative data specified by the user and calculates the rate of occurrence of these patterns in a data set. Although it was designed to facilitate analyses of face-to-face interaction, it is applicable to any data set involving categorical data and sequential information. C-quence queries are constructed using a graphical user interface. The program does not limit the complexity of the sequential patterns specified by the user.

  6. Automated segmentation of dental CBCT image with prior-guided sequential random forests

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Li; Gao, Yaozong; Shi, Feng; Li, Gang [Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599-7513 (United States); Chen, Ken-Chung; Tang, Zhen [Surgical Planning Laboratory, Department of Oral and Maxillofacial Surgery, Houston Methodist Research Institute, Houston, Texas 77030 (United States); Xia, James J., E-mail: dgshen@med.unc.edu, E-mail: JXia@HoustonMethodist.org [Surgical Planning Laboratory, Department of Oral and Maxillofacial Surgery, Houston Methodist Research Institute, Houston, Texas 77030 (United States); Department of Surgery (Oral and Maxillofacial Surgery), Weill Medical College, Cornell University, New York, New York 10065 (United States); Department of Oral and Craniomaxillofacial Surgery, Shanghai Jiao Tong University School of Medicine, Shanghai Ninth People’s Hospital, Shanghai 200011 (China); Shen, Dinggang, E-mail: dgshen@med.unc.edu, E-mail: JXia@HoustonMethodist.org [Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599-7513 and Department of Brain and Cognitive Engineering, Korea University, Seoul 02841 (Korea, Republic of)

    2016-01-15

    Purpose: Cone-beam computed tomography (CBCT) is an increasingly utilized imaging modality for the diagnosis and treatment planning of the patients with craniomaxillofacial (CMF) deformities. Accurate segmentation of CBCT image is an essential step to generate 3D models for the diagnosis and treatment planning of the patients with CMF deformities. However, due to the image artifacts caused by beam hardening, imaging noise, inhomogeneity, truncation, and maximal intercuspation, it is difficult to segment the CBCT. Methods: In this paper, the authors present a new automatic segmentation method to address these problems. Specifically, the authors first employ a majority voting method to estimate the initial segmentation probability maps of both mandible and maxilla based on multiple aligned expert-segmented CBCT images. These probability maps provide an important prior guidance for CBCT segmentation. The authors then extract both the appearance features from CBCTs and the context features from the initial probability maps to train the first-layer of random forest classifier that can select discriminative features for segmentation. Based on the first-layer of trained classifier, the probability maps are updated, which will be employed to further train the next layer of random forest classifier. By iteratively training the subsequent random forest classifier using both the original CBCT features and the updated segmentation probability maps, a sequence of classifiers can be derived for accurate segmentation of CBCT images. Results: Segmentation results on CBCTs of 30 subjects were both quantitatively and qualitatively validated based on manually labeled ground truth. The average Dice ratios of mandible and maxilla by the authors’ method were 0.94 and 0.91, respectively, which are significantly better than the state-of-the-art method based on sparse representation (p-value < 0.001). Conclusions: The authors have developed and validated a novel fully automated method

  7. Automated segmentation of dental CBCT image with prior-guided sequential random forests

    International Nuclear Information System (INIS)

    Wang, Li; Gao, Yaozong; Shi, Feng; Li, Gang; Chen, Ken-Chung; Tang, Zhen; Xia, James J.; Shen, Dinggang

    2016-01-01

    Purpose: Cone-beam computed tomography (CBCT) is an increasingly utilized imaging modality for the diagnosis and treatment planning of the patients with craniomaxillofacial (CMF) deformities. Accurate segmentation of CBCT image is an essential step to generate 3D models for the diagnosis and treatment planning of the patients with CMF deformities. However, due to the image artifacts caused by beam hardening, imaging noise, inhomogeneity, truncation, and maximal intercuspation, it is difficult to segment the CBCT. Methods: In this paper, the authors present a new automatic segmentation method to address these problems. Specifically, the authors first employ a majority voting method to estimate the initial segmentation probability maps of both mandible and maxilla based on multiple aligned expert-segmented CBCT images. These probability maps provide an important prior guidance for CBCT segmentation. The authors then extract both the appearance features from CBCTs and the context features from the initial probability maps to train the first-layer of random forest classifier that can select discriminative features for segmentation. Based on the first-layer of trained classifier, the probability maps are updated, which will be employed to further train the next layer of random forest classifier. By iteratively training the subsequent random forest classifier using both the original CBCT features and the updated segmentation probability maps, a sequence of classifiers can be derived for accurate segmentation of CBCT images. Results: Segmentation results on CBCTs of 30 subjects were both quantitatively and qualitatively validated based on manually labeled ground truth. The average Dice ratios of mandible and maxilla by the authors’ method were 0.94 and 0.91, respectively, which are significantly better than the state-of-the-art method based on sparse representation (p-value < 0.001). Conclusions: The authors have developed and validated a novel fully automated method

  8. Top-down attention affects sequential regularity representation in the human visual system.

    Science.gov (United States)

    Kimura, Motohiro; Widmann, Andreas; Schröger, Erich

    2010-08-01

    Recent neuroscience studies using visual mismatch negativity (visual MMN), an event-related brain potential (ERP) index of memory-mismatch processes in the visual sensory system, have shown that although sequential regularities embedded in successive visual stimuli can be automatically represented in the visual sensory system, an existence of sequential regularity itself does not guarantee that the sequential regularity will be automatically represented. In the present study, we investigated the effects of top-down attention on sequential regularity representation in the visual sensory system. Our results showed that a sequential regularity (SSSSD) embedded in a modified oddball sequence where infrequent deviant (D) and frequent standard stimuli (S) differing in luminance were regularly presented (SSSSDSSSSDSSSSD...) was represented in the visual sensory system only when participants attended the sequential regularity in luminance, but not when participants ignored the stimuli or simply attended the dimension of luminance per se. This suggests that top-down attention affects sequential regularity representation in the visual sensory system and that top-down attention is a prerequisite for particular sequential regularities to be represented. Copyright 2010 Elsevier B.V. All rights reserved.

  9. EXPERIMENTS TOWARDS DETERMINING BEST TRAINING SAMPLE SIZE FOR AUTOMATED EVALUATION OF DESCRIPTIVE ANSWERS THROUGH SEQUENTIAL MINIMAL OPTIMIZATION

    Directory of Open Access Journals (Sweden)

    Sunil Kumar C

    2014-01-01

    Full Text Available With number of students growing each year there is a strong need to automate systems capable of evaluating descriptive answers. Unfortunately, there aren’t many systems capable of performing this task. In this paper, we use a machine learning tool called LightSIDE to accomplish auto evaluation and scoring of descriptive answers. Our experiments are designed to cater to our primary goal of identifying the optimum training sample size so as to get optimum auto scoring. Besides the technical overview and the experiments design, the paper also covers challenges, benefits of the system. We also discussed interdisciplinary areas for future research on this topic.

  10. Mining compressing sequential problems

    NARCIS (Netherlands)

    Hoang, T.L.; Mörchen, F.; Fradkin, D.; Calders, T.G.K.

    2012-01-01

    Compression based pattern mining has been successfully applied to many data mining tasks. We propose an approach based on the minimum description length principle to extract sequential patterns that compress a database of sequences well. We show that mining compressing patterns is NP-Hard and

  11. Fast sequential Monte Carlo methods for counting and optimization

    CERN Document Server

    Rubinstein, Reuven Y; Vaisman, Radislav

    2013-01-01

    A comprehensive account of the theory and application of Monte Carlo methods Based on years of research in efficient Monte Carlo methods for estimation of rare-event probabilities, counting problems, and combinatorial optimization, Fast Sequential Monte Carlo Methods for Counting and Optimization is a complete illustration of fast sequential Monte Carlo techniques. The book provides an accessible overview of current work in the field of Monte Carlo methods, specifically sequential Monte Carlo techniques, for solving abstract counting and optimization problems. Written by authorities in the

  12. Computing sequential equilibria for two-player games

    DEFF Research Database (Denmark)

    Miltersen, Peter Bro

    2006-01-01

    Koller, Megiddo and von Stengel showed how to efficiently compute minimax strategies for two-player extensive-form zero-sum games with imperfect information but perfect recall using linear programming and avoiding conversion to normal form. Their algorithm has been used by AI researchers...... for constructing prescriptive strategies for concrete, often fairly large games. Koller and Pfeffer pointed out that the strategies obtained by the algorithm are not necessarily sequentially rational and that this deficiency is often problematic for the practical applications. We show how to remove this deficiency...... by modifying the linear programs constructed by Koller, Megiddo and von Stengel so that pairs of strategies forming a sequential equilibrium are computed. In particular, we show that a sequential equilibrium for a two-player zero-sum game with imperfect information but perfect recall can be found in polynomial...

  13. Computing Sequential Equilibria for Two-Player Games

    DEFF Research Database (Denmark)

    Miltersen, Peter Bro; Sørensen, Troels Bjerre

    2006-01-01

    Koller, Megiddo and von Stengel showed how to efficiently compute minimax strategies for two-player extensive-form zero-sum games with imperfect information but perfect recall using linear programming and avoiding conversion to normal form. Koller and Pfeffer pointed out that the strategies...... obtained by the algorithm are not necessarily sequentially rational and that this deficiency is often problematic for the practical applications. We show how to remove this deficiency by modifying the linear programs constructed by Koller, Megiddo and von Stengel so that pairs of strategies forming...... a sequential equilibrium are computed. In particular, we show that a sequential equilibrium for a two-player zero-sum game with imperfect information but perfect recall can be found in polynomial time. In addition, the equilibrium we find is normal-form perfect. Our technique generalizes to general-sum games...

  14. Process automation

    International Nuclear Information System (INIS)

    Moser, D.R.

    1986-01-01

    Process automation technology has been pursued in the chemical processing industries and to a very limited extent in nuclear fuel reprocessing. Its effective use has been restricted in the past by the lack of diverse and reliable process instrumentation and the unavailability of sophisticated software designed for process control. The Integrated Equipment Test (IET) facility was developed by the Consolidated Fuel Reprocessing Program (CFRP) in part to demonstrate new concepts for control of advanced nuclear fuel reprocessing plants. A demonstration of fuel reprocessing equipment automation using advanced instrumentation and a modern, microprocessor-based control system is nearing completion in the facility. This facility provides for the synergistic testing of all chemical process features of a prototypical fuel reprocessing plant that can be attained with unirradiated uranium-bearing feed materials. The unique equipment and mission of the IET facility make it an ideal test bed for automation studies. This effort will provide for the demonstration of the plant automation concept and for the development of techniques for similar applications in a full-scale plant. A set of preliminary recommendations for implementing process automation has been compiled. Some of these concepts are not generally recognized or accepted. The automation work now under way in the IET facility should be useful to others in helping avoid costly mistakes because of the underutilization or misapplication of process automation. 6 figs

  15. Sensitivity Analysis in Sequential Decision Models.

    Science.gov (United States)

    Chen, Qiushi; Ayer, Turgay; Chhatwal, Jagpreet

    2017-02-01

    Sequential decision problems are frequently encountered in medical decision making, which are commonly solved using Markov decision processes (MDPs). Modeling guidelines recommend conducting sensitivity analyses in decision-analytic models to assess the robustness of the model results against the uncertainty in model parameters. However, standard methods of conducting sensitivity analyses cannot be directly applied to sequential decision problems because this would require evaluating all possible decision sequences, typically in the order of trillions, which is not practically feasible. As a result, most MDP-based modeling studies do not examine confidence in their recommended policies. In this study, we provide an approach to estimate uncertainty and confidence in the results of sequential decision models. First, we provide a probabilistic univariate method to identify the most sensitive parameters in MDPs. Second, we present a probabilistic multivariate approach to estimate the overall confidence in the recommended optimal policy considering joint uncertainty in the model parameters. We provide a graphical representation, which we call a policy acceptability curve, to summarize the confidence in the optimal policy by incorporating stakeholders' willingness to accept the base case policy. For a cost-effectiveness analysis, we provide an approach to construct a cost-effectiveness acceptability frontier, which shows the most cost-effective policy as well as the confidence in that for a given willingness to pay threshold. We demonstrate our approach using a simple MDP case study. We developed a method to conduct sensitivity analysis in sequential decision models, which could increase the credibility of these models among stakeholders.

  16. The sequential structure of brain activation predicts skill.

    Science.gov (United States)

    Anderson, John R; Bothell, Daniel; Fincham, Jon M; Moon, Jungaa

    2016-01-29

    In an fMRI study, participants were trained to play a complex video game. They were scanned early and then again after substantial practice. While better players showed greater activation in one region (right dorsal striatum) their relative skill was better diagnosed by considering the sequential structure of whole brain activation. Using a cognitive model that played this game, we extracted a characterization of the mental states that are involved in playing a game and the statistical structure of the transitions among these states. There was a strong correspondence between this measure of sequential structure and the skill of different players. Using multi-voxel pattern analysis, it was possible to recognize, with relatively high accuracy, the cognitive states participants were in during particular scans. We used the sequential structure of these activation-recognized states to predict the skill of individual players. These findings indicate that important features about information-processing strategies can be identified from a model-based analysis of the sequential structure of brain activation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. A one-sided sequential test

    Energy Technology Data Exchange (ETDEWEB)

    Racz, A.; Lux, I. [Hungarian Academy of Sciences, Budapest (Hungary). Atomic Energy Research Inst.

    1996-04-16

    The applicability of the classical sequential probability ratio testing (SPRT) for early failure detection problems is limited by the fact that there is an extra time delay between the occurrence of the failure and its first recognition. Chien and Adams developed a method to minimize this time for the case when the problem can be formulated as testing the mean value of a Gaussian signal. In our paper we propose a procedure that can be applied for both mean and variance testing and that minimizes the time delay. The method is based on a special parametrization of the classical SPRT. The one-sided sequential tests (OSST) can reproduce the results of the Chien-Adams test when applied for mean values. (author).

  18. Automated processing integrated with a microflow cytometer for pathogen detection in clinical matrices.

    Science.gov (United States)

    Golden, J P; Verbarg, J; Howell, P B; Shriver-Lake, L C; Ligler, F S

    2013-02-15

    A spinning magnetic trap (MagTrap) for automated sample processing was integrated with a microflow cytometer capable of simultaneously detecting multiple targets to provide an automated sample-to-answer diagnosis in 40 min. After target capture on fluorescently coded magnetic microspheres, the magnetic trap automatically concentrated the fluorescently coded microspheres, separated the captured target from the sample matrix, and exposed the bound target sequentially to biotinylated tracer molecules and streptavidin-labeled phycoerythrin. The concentrated microspheres were then hydrodynamically focused in a microflow cytometer capable of 4-color analysis (two wavelengths for microsphere identification, one for light scatter to discriminate single microspheres and one for phycoerythrin bound to the target). A three-fold decrease in sample preparation time and an improved detection limit, independent of target preconcentration, was demonstrated for detection of Escherichia coli 0157:H7 using the MagTrap as compared to manual processing. Simultaneous analysis of positive and negative controls, along with the assay reagents specific for the target, was used to obtain dose-response curves, demonstrating the potential for quantification of pathogen load in buffer and serum. Published by Elsevier B.V.

  19. Automated Microfluidic Platform for Serial Polymerase Chain Reaction and High-Resolution Melting Analysis.

    Science.gov (United States)

    Cao, Weidong; Bean, Brian; Corey, Scott; Coursey, Johnathan S; Hasson, Kenton C; Inoue, Hiroshi; Isano, Taisuke; Kanderian, Sami; Lane, Ben; Liang, Hongye; Murphy, Brian; Owen, Greg; Shinoda, Nobuhiko; Zeng, Shulin; Knight, Ivor T

    2016-06-01

    We report the development of an automated genetic analyzer for human sample testing based on microfluidic rapid polymerase chain reaction (PCR) with high-resolution melting analysis (HRMA). The integrated DNA microfluidic cartridge was used on a platform designed with a robotic pipettor system that works by sequentially picking up different test solutions from a 384-well plate, mixing them in the tips, and delivering mixed fluids to the DNA cartridge. A novel image feedback flow control system based on a Canon 5D Mark II digital camera was developed for controlling fluid movement through a complex microfluidic branching network without the use of valves. The same camera was used for measuring the high-resolution melt curve of DNA amplicons that were generated in the microfluidic chip. Owing to fast heating and cooling as well as sensitive temperature measurement in the microfluidic channels, the time frame for PCR and HRMA was dramatically reduced from hours to minutes. Preliminary testing results demonstrated that rapid serial PCR and HRMA are possible while still achieving high data quality that is suitable for human sample testing. © 2015 Society for Laboratory Automation and Screening.

  20. Mining Emerging Sequential Patterns for Activity Recognition in Body Sensor Networks

    DEFF Research Database (Denmark)

    Gu, Tao; Wang, Liang; Chen, Hanhua

    2010-01-01

    Body Sensor Networks oer many applications in healthcare, well-being and entertainment. One of the emerging applications is recognizing activities of daily living. In this paper, we introduce a novel knowledge pattern named Emerging Sequential Pattern (ESP)|a sequential pattern that discovers...... signicant class dierences|to recognize both simple (i.e., sequential) and complex (i.e., interleaved and concurrent) activities. Based on ESPs, we build our complex activity models directly upon the sequential model to recognize both activity types. We conduct comprehensive empirical studies to evaluate...

  1. Discrimination between sequential and simultaneous virtual channels with electrical hearing

    OpenAIRE

    Landsberger, David; Galvin, John J.

    2011-01-01

    In cochlear implants (CIs), simultaneous or sequential stimulation of adjacent electrodes can produce intermediate pitch percepts between those of the component electrodes. However, it is unclear whether simultaneous and sequential virtual channels (VCs) can be discriminated. In this study, CI users were asked to discriminate simultaneous and sequential VCs; discrimination was measured for monopolar (MP) and bipolar + 1 stimulation (BP + 1), i.e., relatively broad and focused stimulation mode...

  2. One-Pot Automated Synthesis of Quasi Triblock Copolymers for Self-Healing Physically Crosslinked Hydrogels.

    Science.gov (United States)

    Voorhaar, Lenny; De Meyer, Bernhard; Du Prez, Filip; Hoogenboom, Richard

    2016-10-01

    The preparation of physically crosslinked hydrogels from quasi ABA-triblock copolymers with a water-soluble middle block and hydrophobic end groups is reported. The hydrophilic monomer N-acryloylmorpholine is copolymerized with hydrophobic isobornyl acrylate via a one-pot sequential monomer addition through reversible addition fragmentation chain-transfer (RAFT) polymerization in an automated parallel synthesizer, allowing systematic variation of polymer chain length and hydrophobic-hydrophilic ratio. Hydrophobic interactions between the outer blocks cause them to phase-separate into larger hydrophobic domains in water, forming physical crosslinks between the polymers. The resulting hydrogels are studied using rheology and their self-healing ability after large strain damage is shown. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Fabrication of micro-Ni arrays by electroless and electrochemical ...

    Indian Academy of Sciences (India)

    Administrator

    in electroless solution. With the help of the membrane, nickel micro-columns of about 1–2 µm diameter were obtained. The surface-deposited nickel layer served as a substrate for the nickel micro-columns, and the resulting material possessed strong mechanical strength. Electrochemical deposition was operated without ...

  4. Hybrid Computerized Adaptive Testing: From Group Sequential Design to Fully Sequential Design

    Science.gov (United States)

    Wang, Shiyu; Lin, Haiyan; Chang, Hua-Hua; Douglas, Jeff

    2016-01-01

    Computerized adaptive testing (CAT) and multistage testing (MST) have become two of the most popular modes in large-scale computer-based sequential testing. Though most designs of CAT and MST exhibit strength and weakness in recent large-scale implementations, there is no simple answer to the question of which design is better because different…

  5. A modular, prospective, semi-automated drug safety monitoring system for use in a distributed data environment.

    Science.gov (United States)

    Gagne, Joshua J; Wang, Shirley V; Rassen, Jeremy A; Schneeweiss, Sebastian

    2014-06-01

    The aim of this study was to develop and test a semi-automated process for conducting routine active safety monitoring for new drugs in a network of electronic healthcare databases. We built a modular program that semi-automatically performs cohort identification, confounding adjustment, diagnostic checks, aggregation and effect estimation across multiple databases, and application of a sequential alerting algorithm. During beta-testing, we applied the system to five databases to evaluate nine examples emulating prospective monitoring with retrospective data (five pairs for which we expected signals, two negative controls, and two examples for which it was uncertain whether a signal would be expected): cerivastatin versus atorvastatin and rhabdomyolysis; paroxetine versus tricyclic antidepressants and gastrointestinal bleed; lisinopril versus angiotensin receptor blockers and angioedema; ciprofloxacin versus macrolide antibiotics and Achilles tendon rupture; rofecoxib versus non-selective non-steroidal anti-inflammatory drugs (ns-NSAIDs) and myocardial infarction; telithromycin versus azithromycin and hepatotoxicity; rosuvastatin versus atorvastatin and diabetes and rhabdomyolysis; and celecoxib versus ns-NSAIDs and myocardial infarction. We describe the program, the necessary inputs, and the assumed data environment. In beta-testing, the system generated four alerts, all among positive control examples (i.e., lisinopril and angioedema; rofecoxib and myocardial infarction; ciprofloxacin and tendon rupture; and cerivastatin and rhabdomyolysis). Sequential effect estimates for each example were consistent in direction and magnitude with existing literature. Beta-testing across nine drug-outcome examples demonstrated the feasibility of the proposed semi-automated prospective monitoring approach. In retrospective assessments, the system identified an increased risk of myocardial infarction with rofecoxib and an increased risk of rhabdomyolysis with cerivastatin years

  6. Sequential dependencies in magnitude scaling of loudness

    DEFF Research Database (Denmark)

    Joshi, Suyash Narendra; Jesteadt, Walt

    2013-01-01

    Ten normally hearing listeners used a programmable sone-potentiometer knob to adjust the level of a 1000-Hz sinusoid to match the loudness of numbers presented to them in a magnitude production task. Three different power-law exponents (0.15, 0.30, and 0.60) and a log-law with equal steps in d......B were used to program the sone-potentiometer. The knob settings systematically influenced the form of the loudness function. Time series analysis was used to assess the sequential dependencies in the data, which increased with increasing exponent and were greatest for the log-law. It would be possible......, therefore, to choose knob properties that minimized these dependencies. When the sequential dependencies were removed from the data, the slope of the loudness functions did not change, but the variability decreased. Sequential dependencies were only present when the level of the tone on the previous trial...

  7. Visual short-term memory for sequential arrays.

    Science.gov (United States)

    Kumar, Arjun; Jiang, Yuhong

    2005-04-01

    The capacity of visual short-term memory (VSTM) for a single visual display has been investigated in past research, but VSTM for multiple sequential arrays has been explored only recently. In this study, we investigate the capacity of VSTM across two sequential arrays separated by a variable stimulus onset asynchrony (SOA). VSTM for spatial locations (Experiment 1), colors (Experiments 2-4), orientations (Experiments 3 and 4), and conjunction of color and orientation (Experiment 4) were tested, with the SOA across the two sequential arrays varying from 100 to 1,500 msec. We find that VSTM for the trailing array is much better than VSTM for the leading array, but when averaged across the two arrays VSTM has a constant capacity independent of the SOA. We suggest that multiple displays compete for retention in VSTM and that separating information into two temporally discrete groups does not enhance the overall capacity of VSTM.

  8. A study on computer-aided diagnosis based on temporal subtraction of sequential chest radiographs (in Japanese)

    International Nuclear Information System (INIS)

    Kano, Akiko

    2001-01-01

    An automated digital image subtraction technique for use with pairs of temporally sequential chest radiographs has been developed to aid radiologists in the detection of interval changes. Automated image registration based on nonlinear geometric warping is performed prior to subtraction in order to deal with complicated radiographic misregistration. Processing includes global matching, to achieve rough registration between the entire lung fields in the two images, and local matching, based on a cross-correlation method, to determine local shift values for a number of small regions. A proper warping of x,y-coordinates is determined by fitting two-dimensional polynomials to the distributions of the shift values. One image is warped and then subtracted from the other. The resultant subtraction images were able to enhance the conspicuity of various types of interval changes. Improved global matching based on a weighted template matching method achieved robust registration even with photofluorographs taken in chest mass screening programs, which had previously presented us with a relatively large number of poor-registration images. The new method was applied to 129 pairs of chest mass screening images, and offered registration accuracy as good as manual global matching. An observer test using 114 cases including 57 lung cancer cases presented better sensitivity and specificity on average compared to conventional comparison readings. In addition, newly developed image processing that eliminates the rib edge artifacts in subtraction images was applied to 26 images having pathological interval changes; results showed the potential for application to automated schemes for the detection of interval change patterns. With its capacity to improve the diagnostic accuracy of chest radiographs, the chest temporal subtraction technique promises to become an important element of computer-aided diagnosis (CAD) systems

  9. The target-to-foils shift in simultaneous and sequential lineups.

    Science.gov (United States)

    Clark, Steven E; Davey, Sherrie L

    2005-04-01

    A theoretical cornerstone in eyewitness identification research is the proposition that witnesses, in making decisions from standard simultaneous lineups, make relative judgments. The present research considers two sources of support for this proposal. An experiment by G. L. Wells (1993) showed that if the target is removed from a lineup, witnesses shift their responses to pick foils, rather than rejecting the lineups, a result we will term a target-to-foils shift. Additional empirical support is provided by results from sequential lineups which typically show higher accuracy than simultaneous lineups, presumably because of a decrease in the use of relative judgments in making identification decisions. The combination of these two lines of research suggests that the target-to-foils shift should be reduced in sequential lineups relative to simultaneous lineups. Results of two experiments showed an overall advantage for sequential lineups, but also showed a target-to-foils shift equal in size for simultaneous and sequential lineups. Additional analyses indicated that the target-to-foils shift in sequential lineups was moderated in part by an order effect and was produced with (Experiment 2) or without (Experiment 1) a shift in decision criterion. This complex pattern of results suggests that more work is needed to understand the processes which underlie decisions in simultaneous and sequential lineups.

  10. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Results: Safe injection procedures regarding final waste disposal were sufficiently adopted, while measures regarding disposable injection equipment, waste containers, hand hygiene, as well as injection practices were inadequately carried out. Lack of job aid posters that promote safe injection and safe disposal of ...

  11. Dynamics-based sequential memory: Winnerless competition of patterns

    International Nuclear Information System (INIS)

    Seliger, Philip; Tsimring, Lev S.; Rabinovich, Mikhail I.

    2003-01-01

    We introduce a biologically motivated dynamical principle of sequential memory which is based on winnerless competition (WLC) of event images. This mechanism is implemented in a two-layer neural model of sequential spatial memory. We present the learning dynamics which leads to the formation of a WLC network. After learning, the system is capable of associative retrieval of prerecorded sequences of patterns

  12. Sequential, progressive, equal-power, reflective beam-splitter arrays

    Science.gov (United States)

    Manhart, Paul K.

    2017-11-01

    The equations to calculate equal-power reflectivity of a sequential series of beam splitters is presented. Non-sequential optical design examples are offered for uniform illumination using diode lasers. Objects created using Boolean operators and Swept Surfaces can create objects capable of reflecting light into predefined elevation and azimuth angles. Analysis of the illumination patterns for the array are also presented.

  13. A Chip-Capillary Hybrid Device for Automated Transfer of Sample Pre-Separated by Capillary Isoelectric Focusing to Parallel Capillary Gel Electrophoresis for Two-Dimensional Protein Separation

    Science.gov (United States)

    Lu, Joann J.; Wang, Shili; Li, Guanbin; Wang, Wei; Pu, Qiaosheng; Liu, Shaorong

    2012-01-01

    In this report, we introduce a chip-capillary hybrid device to integrate capillary isoelectric focusing (CIEF) with parallel capillary sodium dodecyl sulfate – polyacrylamide gel electrophoresis (SDS-PAGE) or capillary gel electrophoresis (CGE) toward automating two-dimensional (2D) protein separations. The hybrid device consists of three chips that are butted together. The middle chip can be moved between two positions to re-route the fluidic paths, which enables the performance of CIEF and injection of proteins partially resolved by CIEF to CGE capillaries for parallel CGE separations in a continuous and automated fashion. Capillaries are attached to the other two chips to facilitate CIEF and CGE separations and to extend the effective lengths of CGE columns. Specifically, we illustrate the working principle of the hybrid device, develop protocols for producing and preparing the hybrid device, and demonstrate the feasibility of using this hybrid device for automated injection of CIEF-separated sample to parallel CGE for 2D protein separations. Potentials and problems associated with the hybrid device are also discussed. PMID:22830584

  14. Basal ganglia and cortical networks for sequential ordering and rhythm of complex movements

    Directory of Open Access Journals (Sweden)

    Jeffery G. Bednark

    2015-07-01

    Full Text Available Voluntary actions require the concurrent engagement and coordinated control of complex temporal (e.g. rhythm and ordinal motor processes. Using high-resolution functional magnetic resonance imaging (fMRI and multi-voxel pattern analysis (MVPA, we sought to determine the degree to which these complex motor processes are dissociable in basal ganglia and cortical networks. We employed three different finger-tapping tasks that differed in the demand on the sequential temporal rhythm or sequential ordering of submovements. Our results demonstrate that sequential rhythm and sequential order tasks were partially dissociable based on activation differences. The sequential rhythm task activated a widespread network centered around the SMA and basal-ganglia regions including the dorsomedial putamen and caudate nucleus, while the sequential order task preferentially activated a fronto-parietal network. There was also extensive overlap between sequential rhythm and sequential order tasks, with both tasks commonly activating bilateral premotor, supplementary motor, and superior/inferior parietal cortical regions, as well as regions of the caudate/putamen of the basal ganglia and the ventro-lateral thalamus. Importantly, within the cortical regions that were active for both complex movements, MVPA could accurately classify different patterns of activation for the sequential rhythm and sequential order tasks. In the basal ganglia, however, overlapping activation for the sequential rhythm and sequential order tasks, which was found in classic motor circuits of the putamen and ventro-lateral thalamus, could not be accurately differentiated by MVPA. Overall, our results highlight the convergent architecture of the motor system, where complex motor information that is spatially distributed in the cortex converges into a more compact representation in the basal ganglia.

  15. Sensing of chlorpheniramine in pharmaceutical applications by sequential injector coupled with potentiometer

    Directory of Open Access Journals (Sweden)

    Tawfik A. Saleh

    2011-11-01

    Full Text Available This paper reports on development of a system consisting of a portable sequential injector coupled with potentiometric unit for sensing of chlorpheniramine (CPA, based on the reaction of CPA with potassium permanganate in acidic media. Various experimental conditions affecting the potential intensity were studied and incorporated into the procedure. Under the optimum conditions, linear relationship between the CPA concentration and peak area was obtained for the concentration range of 0.1–50 ppm. The method reflects good recovery with relative standard deviation (RSD<3%. The detection limit was 0.05 ppm. The developed method was successfully applied for determination of CPA in pure form and in pharmaceutical dosage forms. The results, obtained using the method, are in accord with the results of the British pharmacopoeia method. In addition to its accuracy and precision, the method has the advantages of being simple, inexpensive and rapid. Keywords: Sensing, Flow injection, Chlorpheniramine, Potentiometry

  16. The sequential price of anarchy for atomic congestion games

    NARCIS (Netherlands)

    de Jong, Jasper; Uetz, Marc Jochen; Liu, Tie-Yan; Qi, Qi; Ye, Yinyu

    2014-01-01

    In situations without central coordination, the price of anarchy relates the quality of any Nash equilibrium to the quality of a global optimum. Instead of assuming that all players choose their actions simultaneously, we consider games where players choose their actions sequentially. The sequential

  17. Automated sample preparation using membrane microtiter extraction for bioanalytical mass spectrometry.

    Science.gov (United States)

    Janiszewski, J; Schneider, P; Hoffmaster, K; Swyden, M; Wells, D; Fouda, H

    1997-01-01

    The development and application of membrane solid phase extraction (SPE) in 96-well microtiter plate format is described for the automated analysis of drugs in biological fluids. The small bed volume of the membrane allows elution of the analyte in a very small solvent volume, permitting direct HPLC injection and negating the need for the time consuming solvent evaporation step. A programmable liquid handling station (Quadra 96) was modified to automate all SPE steps. To avoid drying of the SPE bed and to enhance the analytical precision a novel protocol for performing the condition, load and wash steps in rapid succession was utilized. A block of 96 samples can now be extracted in 10 min., about 30 times faster than manual solvent extraction or single cartridge SPE methods. This processing speed complements the high-throughput speed of contemporary high performance liquid chromatography mass spectrometry (HPLC/MS) analysis. The quantitative analysis of a test analyte (Ziprasidone) in plasma demonstrates the utility and throughput of membrane SPE in combination with HPLC/MS. The results obtained with the current automated procedure compare favorably with those obtained using solvent and traditional solid phase extraction methods. The method has been used for the analysis of numerous drug prototypes in biological fluids to support drug discovery efforts.

  18. Computer programmes for the control and data manipulation of a sequential x-ray-fluorescence spectrometer

    International Nuclear Information System (INIS)

    Spimpolo, G.F.

    1984-01-01

    Two computer programmes have been written for use on a fully automated Siemens SRS200 sequential X-ray-fluorescence spectrometer. The first of these is used to control the spectrometer via an LC200 logic controller using a Data General Nova IV minicomputer; the second is used for the on-line evaluation of the intensity results and the printout of the analytical results. This system is an alternative to the systems offered by Siemens Ltd, which consist of a Process PR310 or Digital DEC PDP1103 computer and the Siemens Spectra 310 software package. The multibatch capabilities of the programmes, with the option of measuring one sample or a tray of samples before the results are calculated, give the new programmes a major advantage over the dedicated software and, together with the elimination of human error in calculation, have resulted in increased efficiency and quality in routine analyses. A description is given of the two programmes, as well as instruction and guidelines to the user

  19. Native Frames: Disentangling Sequential from Concerted Three-Body Fragmentation

    Science.gov (United States)

    Rajput, Jyoti; Severt, T.; Berry, Ben; Jochim, Bethany; Feizollah, Peyman; Kaderiya, Balram; Zohrabi, M.; Ablikim, U.; Ziaee, Farzaneh; Raju P., Kanaka; Rolles, D.; Rudenko, A.; Carnes, K. D.; Esry, B. D.; Ben-Itzhak, I.

    2018-03-01

    A key question concerning the three-body fragmentation of polyatomic molecules is the distinction of sequential and concerted mechanisms, i.e., the stepwise or simultaneous cleavage of bonds. Using laser-driven fragmentation of OCS into O++C++S+ and employing coincidence momentum imaging, we demonstrate a novel method that enables the clear separation of sequential and concerted breakup. The separation is accomplished by analyzing the three-body fragmentation in the native frame associated with each step and taking advantage of the rotation of the intermediate molecular fragment, CO2 + or CS2 + , before its unimolecular dissociation. This native-frame method works for any projectile (electrons, ions, or photons), provides details on each step of the sequential breakup, and enables the retrieval of the relevant spectra for sequential and concerted breakup separately. Specifically, this allows the determination of the branching ratio of all these processes in OCS3 + breakup. Moreover, we find that the first step of sequential breakup is tightly aligned along the laser polarization and identify the likely electronic states of the intermediate dication that undergo unimolecular dissociation in the second step. Finally, the separated concerted breakup spectra show clearly that the central carbon atom is preferentially ejected perpendicular to the laser field.

  20. Automated microscopic characterization of metallic ores with image analysis: a key to improve ore processing. I: test of the methodology

    International Nuclear Information System (INIS)

    Berrezueta, E.; Castroviejo, R.

    2007-01-01

    Ore microscopy has traditionally been an important support to control ore processing, but the volume of present day processes is beyond the reach of human operators. Automation is therefore compulsory, but its development through digital image analysis, DIA, is limited by various problems, such as the similarity in reflectance values of some important ores, their anisotropism, and the performance of instruments and methods. The results presented show that automated identification and quantification by DIA are possible through multiband (RGB) determinations with a research 3CCD video camera on reflected light microscope. These results were obtained by systematic measurement of selected ores accounting for most of the industrial applications. Polarized light is avoided, so the effects of anisotropism can be neglected. Quality control at various stages and statistical analysis are important, as is the application of complementary criteria (e.g. metallogenetic). The sequential methodology is described and shown through practical examples. (Author)

  1. Anti-tumor activity of high-dose EGFR tyrosine kinase inhibitor and sequential docetaxel in wild type EGFR non-small cell lung cancer cell nude mouse xenografts

    OpenAIRE

    Tang, Ning; Zhang, Qianqian; Fang, Shu; Han, Xiao; Wang, Zhehai

    2016-01-01

    Treatment of non-small-cell lung cancer (NSCLC) with wild-type epidermal growth factor receptor (EGFR) is still a challenge. This study explored antitumor activity of high-dose icotinib (an EGFR tyrosine kinase inhibitor) plus sequential docetaxel against wild-type EGFR NSCLC cells-generated nude mouse xenografts. Nude mice were subcutaneously injected with wild-type EGFR NSCLC A549 cells and divided into different groups for 3-week treatment. Tumor xenograft volumes were monitored and record...

  2. Redesign and Automation of a mold for manufacturing of refrigerated display cases using Polyurethane Foam Injection

    Directory of Open Access Journals (Sweden)

    Eugenio Yime

    2016-10-01

    Full Text Available Context: To stay competitive over time, a company must continually submit their processes to improvements and updates. Herein are proposed some improvements with regard to safety at work and the reduction of time that occurs during the operation of a mold for manufacturing refrigerators. Method: Some operating conditions of the mold are analyzed and then some factors affecting the processing time and the safety of operating personnel are established. The weaknesses found are related to the intrinsic design of the mold, which raises the need for a structural redesign that also includes automation. Results: It is presented a new design and way to operate the mold which reduces the risk of accidents at having no heavy loads over operator heads. Another contribution of the redesign is the increase in the system rigidity which helps to reduce manufacturing defects. Finally, it is show a automation design which helps to reduce manufacturing times. Conclusions: Significant improvements were obtained in the operation of the mold, such as the reduction of occupational hazards and reduced manufacturing time of refrigerators. These improvements translate into benefits for the company, by reducing costs and increasing production. Both benefits help strengthen the competitiveness of the company.

  3. Campbell and moment measures for finite sequential spatial processes

    NARCIS (Netherlands)

    M.N.M. van Lieshout (Marie-Colette)

    2006-01-01

    textabstractWe define moment and Campbell measures for sequential spatial processes, prove a Campbell-Mecke theorem, and relate the results to their counterparts in the theory of point processes. In particular, we show that any finite sequential spatial process model can be derived as the vector

  4. Sequential Dependencies in Driving

    Science.gov (United States)

    Doshi, Anup; Tran, Cuong; Wilder, Matthew H.; Mozer, Michael C.; Trivedi, Mohan M.

    2012-01-01

    The effect of recent experience on current behavior has been studied extensively in simple laboratory tasks. We explore the nature of sequential effects in the more naturalistic setting of automobile driving. Driving is a safety-critical task in which delayed response times may have severe consequences. Using a realistic driving simulator, we find…

  5. Research on parallel algorithm for sequential pattern mining

    Science.gov (United States)

    Zhou, Lijuan; Qin, Bai; Wang, Yu; Hao, Zhongxiao

    2008-03-01

    Sequential pattern mining is the mining of frequent sequences related to time or other orders from the sequence database. Its initial motivation is to discover the laws of customer purchasing in a time section by finding the frequent sequences. In recent years, sequential pattern mining has become an important direction of data mining, and its application field has not been confined to the business database and has extended to new data sources such as Web and advanced science fields such as DNA analysis. The data of sequential pattern mining has characteristics as follows: mass data amount and distributed storage. Most existing sequential pattern mining algorithms haven't considered the above-mentioned characteristics synthetically. According to the traits mentioned above and combining the parallel theory, this paper puts forward a new distributed parallel algorithm SPP(Sequential Pattern Parallel). The algorithm abides by the principal of pattern reduction and utilizes the divide-and-conquer strategy for parallelization. The first parallel task is to construct frequent item sets applying frequent concept and search space partition theory and the second task is to structure frequent sequences using the depth-first search method at each processor. The algorithm only needs to access the database twice and doesn't generate the candidated sequences, which abates the access time and improves the mining efficiency. Based on the random data generation procedure and different information structure designed, this paper simulated the SPP algorithm in a concrete parallel environment and implemented the AprioriAll algorithm. The experiments demonstrate that compared with AprioriAll, the SPP algorithm had excellent speedup factor and efficiency.

  6. Automated Conflict Resolution, Arrival Management and Weather Avoidance for ATM

    Science.gov (United States)

    Erzberger, H.; Lauderdale, Todd A.; Chu, Yung-Cheng

    2010-01-01

    The paper describes a unified solution to three types of separation assurance problems that occur in en-route airspace: separation conflicts, arrival sequencing, and weather-cell avoidance. Algorithms for solving these problems play a key role in the design of future air traffic management systems such as NextGen. Because these problems can arise simultaneously in any combination, it is necessary to develop integrated algorithms for solving them. A unified and comprehensive solution to these problems provides the foundation for a future air traffic management system that requires a high level of automation in separation assurance. The paper describes the three algorithms developed for solving each problem and then shows how they are used sequentially to solve any combination of these problems. The first algorithm resolves loss-of-separation conflicts and is an evolution of an algorithm described in an earlier paper. The new version generates multiple resolutions for each conflict and then selects the one giving the least delay. Two new algorithms, one for sequencing and merging of arrival traffic, referred to as the Arrival Manager, and the other for weather-cell avoidance are the major focus of the paper. Because these three problems constitute a substantial fraction of the workload of en-route controllers, integrated algorithms to solve them is a basic requirement for automated separation assurance. The paper also reviews the Advanced Airspace Concept, a proposed design for a ground-based system that postulates redundant systems for separation assurance in order to achieve both high levels of safety and airspace capacity. It is proposed that automated separation assurance be introduced operationally in several steps, each step reducing controller workload further while increasing airspace capacity. A fast time simulation was used to determine performance statistics of the algorithm at up to 3 times current traffic levels.

  7. Extensible automated dispersive liquid–liquid microextraction

    Energy Technology Data Exchange (ETDEWEB)

    Li, Songqing; Hu, Lu; Chen, Ketao; Gao, Haixiang, E-mail: hxgao@cau.edu.cn

    2015-05-04

    Highlights: • An extensible automated dispersive liquid–liquid microextraction was developed. • A fully automatic SPE workstation with a modified operation program was used. • Ionic liquid-based in situ DLLME was used as model method. • SPE columns packed with nonwoven polypropylene fiber was used for phase separation. • The approach was applied to the determination of benzoylurea insecticides in water. - Abstract: In this study, a convenient and extensible automated ionic liquid-based in situ dispersive liquid–liquid microextraction (automated IL-based in situ DLLME) was developed. 1-Octyl-3-methylimidazolium bis[(trifluoromethane)sulfonyl]imide ([C{sub 8}MIM]NTf{sub 2}) is formed through the reaction between [C{sub 8}MIM]Cl and lithium bis[(trifluoromethane)sulfonyl]imide (LiNTf{sub 2}) to extract the analytes. Using a fully automatic SPE workstation, special SPE columns packed with nonwoven polypropylene (NWPP) fiber, and a modified operation program, the procedures of the IL-based in situ DLLME, including the collection of a water sample, injection of an ion exchange solvent, phase separation of the emulsified solution, elution of the retained extraction phase, and collection of the eluent into vials, can be performed automatically. The developed approach, coupled with high-performance liquid chromatography–diode array detection (HPLC–DAD), was successfully applied to the detection and concentration determination of benzoylurea (BU) insecticides in water samples. Parameters affecting the extraction performance were investigated and optimized. Under the optimized conditions, the proposed method achieved extraction recoveries of 80% to 89% for water samples. The limits of detection (LODs) of the method were in the range of 0.16–0.45 ng mL{sup −1}. The intra-column and inter-column relative standard deviations (RSDs) were <8.6%. Good linearity (r > 0.9986) was obtained over the calibration range from 2 to 500 ng mL{sup −1}. The proposed

  8. Extensible automated dispersive liquid–liquid microextraction

    International Nuclear Information System (INIS)

    Li, Songqing; Hu, Lu; Chen, Ketao; Gao, Haixiang

    2015-01-01

    Highlights: • An extensible automated dispersive liquid–liquid microextraction was developed. • A fully automatic SPE workstation with a modified operation program was used. • Ionic liquid-based in situ DLLME was used as model method. • SPE columns packed with nonwoven polypropylene fiber was used for phase separation. • The approach was applied to the determination of benzoylurea insecticides in water. - Abstract: In this study, a convenient and extensible automated ionic liquid-based in situ dispersive liquid–liquid microextraction (automated IL-based in situ DLLME) was developed. 1-Octyl-3-methylimidazolium bis[(trifluoromethane)sulfonyl]imide ([C 8 MIM]NTf 2 ) is formed through the reaction between [C 8 MIM]Cl and lithium bis[(trifluoromethane)sulfonyl]imide (LiNTf 2 ) to extract the analytes. Using a fully automatic SPE workstation, special SPE columns packed with nonwoven polypropylene (NWPP) fiber, and a modified operation program, the procedures of the IL-based in situ DLLME, including the collection of a water sample, injection of an ion exchange solvent, phase separation of the emulsified solution, elution of the retained extraction phase, and collection of the eluent into vials, can be performed automatically. The developed approach, coupled with high-performance liquid chromatography–diode array detection (HPLC–DAD), was successfully applied to the detection and concentration determination of benzoylurea (BU) insecticides in water samples. Parameters affecting the extraction performance were investigated and optimized. Under the optimized conditions, the proposed method achieved extraction recoveries of 80% to 89% for water samples. The limits of detection (LODs) of the method were in the range of 0.16–0.45 ng mL −1 . The intra-column and inter-column relative standard deviations (RSDs) were <8.6%. Good linearity (r > 0.9986) was obtained over the calibration range from 2 to 500 ng mL −1 . The proposed method opens a new avenue

  9. Whole-body MR imaging versus sequential multimodal diagnostic algorithm for staging patients with rectal cancer. Cost analysis

    International Nuclear Information System (INIS)

    Huppertz, A.; Charite Universitaetsklinikum Berlin; Schmidt, M.; Schoeffski, O.; Wagner, M.; Asbach, P.; Maurer, M.H.; Puettcher, O.; Strassburg, J.; Stoeckmann, F.

    2010-01-01

    Purpose: To compare the direct costs of two diagnostic algorithms for pretherapeutic TNM staging of rectal cancer. Materials and Methods: In a study including 33 patients (mean age: 62.5 years), the direct fixed and variable costs of a sequential multimodal algorithm (rectoscopy, endoscopic and abdominal ultrasound, chest X-ray, thoracic/abdominal CT in the case of positive findings in abdominal ultrasound or chest X-ray) were compared to those of a novel algorithm of rectoscopy followed by MRI using a whole-body scanner. MRI included T 2w sequences of the rectum, 3D T 1w sequences of the liver and chest after bolus injection of gadoxetic acid, and delayed phases of the liver. The personnel work times, material items, and work processes were tracked to the nearest minute by interviewing those responsible for the process (surgeon, gastroenterologist, two radiologists). The costs of labor and materials were determined from personnel reimbursement data and hospital accounting records. Fixed costs were determined from vendor pricing. Results: The mean MRI time was 55 min. CT was performed in 19 / 33 patients (57 %) causing an additional day of hospitalization (costs 374 Euro). The costs for equipment and material were higher for MRI compared to sequential algorithm (equipment 116 vs. 30 Euro; material 159 vs. 60 Euro per patient). The personnel costs were markedly lower for MRI (436 vs. 732 Euro per patient). Altogether, the absolute cost advantage of MRI was 31.3 % (711 vs. 1035 Euro for sequential algorithm). Conclusion: Substantial savings are achievable with the use of whole-body MRI for the preoperative TNM staging of patients with rectal cancer. (orig.)

  10. Lean automation development : applying lean principles to the automation development process

    OpenAIRE

    Granlund, Anna; Wiktorsson, Magnus; Grahn, Sten; Friedler, Niklas

    2014-01-01

    By a broad empirical study it is indicated that automation development show potential of improvement. In the paper, 13 lean product development principles are contrasted to the automation development process and it is suggested why and how these principles can facilitate, support and improve the automation development process. The paper summarises a description of what characterises a lean automation development process and what consequences it entails. Main differences compared to current pr...

  11. Injecting Errors for Testing Built-In Test Software

    Science.gov (United States)

    Gender, Thomas K.; Chow, James

    2010-01-01

    Two algorithms have been conceived to enable automated, thorough testing of Built-in test (BIT) software. The first algorithm applies to BIT routines that define pass/fail criteria based on values of data read from such hardware devices as memories, input ports, or registers. This algorithm simulates effects of errors in a device under test by (1) intercepting data from the device and (2) performing AND operations between the data and the data mask specific to the device. This operation yields values not expected by the BIT routine. This algorithm entails very small, permanent instrumentation of the software under test (SUT) for performing the AND operations. The second algorithm applies to BIT programs that provide services to users application programs via commands or callable interfaces and requires a capability for test-driver software to read and write the memory used in execution of the SUT. This algorithm identifies all SUT code execution addresses where errors are to be injected, then temporarily replaces the code at those addresses with small test code sequences to inject latent severe errors, then determines whether, as desired, the SUT detects the errors and recovers

  12. pH-gradient chromatofocusing of proteins on a chip

    NARCIS (Netherlands)

    Rho, Hoon Suk; Hanke, Alexander Thomas; Ottens, Marcel; Gardeniers, J.G.E.

    2015-01-01

    We present a novel microfluidic system for the pH-gradient focusing of proteins with the integration of 16 parallel micro-mixers, a micro-column, and a multiplexer. In this work we successfully achieved the creation of 16 non-linear gradients and the generation of a solid-phase micro-column for the

  13. APPLICATION OF PBL IN THE COURSE FLUID AND ELECTRICAL DRIVE SYSTEMS, CASE STUDY: MANUFACTURING AN AUTOMATED PUNCH MACHINE

    Directory of Open Access Journals (Sweden)

    Ahmad Sedaghat

    2017-01-01

    Full Text Available The PBL unit of fluid and electrical drive systems is taught in final semester of undergraduates in mechanical engineering department of the Australian College of Kuwait (ACK. The recent project on an automated punching machine is discovered more appealing to both students and instructors in triggering new ideas and satisfaction end results. In this case study, the way this PBL unit is coordinated and facilitated is explained. Two examples of student works are presented. The aim is to expose the students to real world engineering problems but in a satisfying manner. Similar to real life problems for engineers, restrictions are applied for the students on costs, availability of ACK facilities, and application of automation tools. Students are directly engaged by using technical standards on punching heads and dies, standard tensile testing of plates, and so on. Arduino microprocessor programming, an open-source hardware and software electronic platform, and electro-pneumatic devices are adopted for developing the automated punching machine. The goal of the PBL course is to acquaint students learning based on the concepts of team working, engineering design, professional manufacturing, and sequential testing of the end product. It is found that students achieved their best and developed new skills in this PBL unit as reflected in their portfolios.

  14. On-line complexation/cloud point preconcentration for the sensitive determination of dysprosium in urine by flow injection inductively coupled plasma-optical emission spectrometry

    International Nuclear Information System (INIS)

    Ortega, Claudia; Cerutti, Soledad; Silva, Maria F.; Olsina, Roberto A.; Martinez, Luis D.

    2003-01-01

    An on-line dysprosium preconcentration and determination system based on the hyphenation of cloud point extraction (CPE) to flow injection analysis (FIA) associated with ICP-OES was studied. For the preconcentration of dysprosium, a Dy(III)-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol complex was formed on-line at pH 9.22 in the presence of nonionic micelles of PONPE-7.5. The micellar system containing the complex was thermostated at 30 C in order to promote phase separation, and the surfactant-rich phase was retained in a microcolumn packed with cotton at pH 9.2. The surfactant-rich phase was eluted with 4 mol L -1 nitric acid at a flow rate of 1.5 mL min -1 , directly in the nebulizer of the plasma. An enhancement factor of 50 was obtained for the preconcentration of 50 mL of sample solution. The detection limit value for the preconcentration of 50 mL of aqueous solution of Dy was 0.03 μg L -1 . The precision for 10 replicate determinations at the 2.0 μg L -1 Dy level was 2.2% relative standard deviation (RSD), calculated from the peak heights obtained. The calibration graph using the preconcentration system for dysprosium was linear with a correlation coefficient of 0.9994 at levels near the detection limits up to at least 100 μg L -1 . The method was successfully applied to the determination of dysprosium in urine. (orig.)

  15. Both Automation and Paper.

    Science.gov (United States)

    Purcell, Royal

    1988-01-01

    Discusses the concept of a paperless society and the current situation in library automation. Various applications of automation and telecommunications are addressed, and future library automation is considered. Automation at the Monroe County Public Library in Bloomington, Indiana, is described as an example. (MES)

  16. Automated Groundwater Screening

    International Nuclear Information System (INIS)

    Taylor, Glenn A.; Collard, Leonard B.

    2005-01-01

    The Automated Intruder Analysis has been extended to include an Automated Ground Water Screening option. This option screens 825 radionuclides while rigorously applying the National Council on Radiation Protection (NCRP) methodology. An extension to that methodology is presented to give a more realistic screening factor for those radionuclides which have significant daughters. The extension has the promise of reducing the number of radionuclides which must be tracked by the customer. By combining the Automated Intruder Analysis with the Automated Groundwater Screening a consistent set of assumptions and databases is used. A method is proposed to eliminate trigger values by performing rigorous calculation of the screening factor thereby reducing the number of radionuclides sent to further analysis. Using the same problem definitions as in previous groundwater screenings, the automated groundwater screening found one additional nuclide, Ge-68, which failed the screening. It also found that 18 of the 57 radionuclides contained in NCRP Table 3.1 failed the screening. This report describes the automated groundwater screening computer application

  17. Framework for sequential approximate optimization

    NARCIS (Netherlands)

    Jacobs, J.H.; Etman, L.F.P.; Keulen, van F.; Rooda, J.E.

    2004-01-01

    An object-oriented framework for Sequential Approximate Optimization (SAO) isproposed. The framework aims to provide an open environment for thespecification and implementation of SAO strategies. The framework is based onthe Python programming language and contains a toolbox of Python

  18. A Survey of Multi-Objective Sequential Decision-Making

    OpenAIRE

    Roijers, D.M.; Vamplew, P.; Whiteson, S.; Dazeley, R.

    2013-01-01

    Sequential decision-making problems with multiple objectives arise naturally in practice and pose unique challenges for research in decision-theoretic planning and learning, which has largely focused on single-objective settings. This article surveys algorithms designed for sequential decision-making problems with multiple objectives. Though there is a growing body of literature on this subject, little of it makes explicit under what circumstances special methods are needed to solve multi-obj...

  19. A Sequential Multiplicative Extended Kalman Filter for Attitude Estimation Using Vector Observations

    Science.gov (United States)

    Qin, Fangjun; Jiang, Sai; Zha, Feng

    2018-01-01

    In this paper, a sequential multiplicative extended Kalman filter (SMEKF) is proposed for attitude estimation using vector observations. In the proposed SMEKF, each of the vector observations is processed sequentially to update the attitude, which can make the measurement model linearization more accurate for the next vector observation. This is the main difference to Murrell’s variation of the MEKF, which does not update the attitude estimate during the sequential procedure. Meanwhile, the covariance is updated after all the vector observations have been processed, which is used to account for the special characteristics of the reset operation necessary for the attitude update. This is the main difference to the traditional sequential EKF, which updates the state covariance at each step of the sequential procedure. The numerical simulation study demonstrates that the proposed SMEKF has more consistent and accurate performance in a wide range of initial estimate errors compared to the MEKF and its traditional sequential forms. PMID:29751538

  20. A Sequential Multiplicative Extended Kalman Filter for Attitude Estimation Using Vector Observations

    Directory of Open Access Journals (Sweden)

    Fangjun Qin

    2018-05-01

    Full Text Available In this paper, a sequential multiplicative extended Kalman filter (SMEKF is proposed for attitude estimation using vector observations. In the proposed SMEKF, each of the vector observations is processed sequentially to update the attitude, which can make the measurement model linearization more accurate for the next vector observation. This is the main difference to Murrell’s variation of the MEKF, which does not update the attitude estimate during the sequential procedure. Meanwhile, the covariance is updated after all the vector observations have been processed, which is used to account for the special characteristics of the reset operation necessary for the attitude update. This is the main difference to the traditional sequential EKF, which updates the state covariance at each step of the sequential procedure. The numerical simulation study demonstrates that the proposed SMEKF has more consistent and accurate performance in a wide range of initial estimate errors compared to the MEKF and its traditional sequential forms.

  1. Asynchronous Operators of Sequential Logic Venjunction & Sequention

    CERN Document Server

    Vasyukevich, Vadim

    2011-01-01

    This book is dedicated to new mathematical instruments assigned for logical modeling of the memory of digital devices. The case in point is logic-dynamical operation named venjunction and venjunctive function as well as sequention and sequentional function. Venjunction and sequention operate within the framework of sequential logic. In a form of the corresponding equations, they organically fit analytical expressions of Boolean algebra. Thus, a sort of symbiosis is formed using elements of asynchronous sequential logic on the one hand and combinational logic on the other hand. So, asynchronous

  2. Human visual system automatically encodes sequential regularities of discrete events.

    Science.gov (United States)

    Kimura, Motohiro; Schröger, Erich; Czigler, István; Ohira, Hideki

    2010-06-01

    For our adaptive behavior in a dynamically changing environment, an essential task of the brain is to automatically encode sequential regularities inherent in the environment into a memory representation. Recent studies in neuroscience have suggested that sequential regularities embedded in discrete sensory events are automatically encoded into a memory representation at the level of the sensory system. This notion is largely supported by evidence from investigations using auditory mismatch negativity (auditory MMN), an event-related brain potential (ERP) correlate of an automatic memory-mismatch process in the auditory sensory system. However, it is still largely unclear whether or not this notion can be generalized to other sensory modalities. The purpose of the present study was to investigate the contribution of the visual sensory system to the automatic encoding of sequential regularities using visual mismatch negativity (visual MMN), an ERP correlate of an automatic memory-mismatch process in the visual sensory system. To this end, we conducted a sequential analysis of visual MMN in an oddball sequence consisting of infrequent deviant and frequent standard stimuli, and tested whether the underlying memory representation of visual MMN generation contains only a sensory memory trace of standard stimuli (trace-mismatch hypothesis) or whether it also contains sequential regularities extracted from the repetitive standard sequence (regularity-violation hypothesis). The results showed that visual MMN was elicited by first deviant (deviant stimuli following at least one standard stimulus), second deviant (deviant stimuli immediately following first deviant), and first standard (standard stimuli immediately following first deviant), but not by second standard (standard stimuli immediately following first standard). These results are consistent with the regularity-violation hypothesis, suggesting that the visual sensory system automatically encodes sequential

  3. A Bayesian Theory of Sequential Causal Learning and Abstract Transfer.

    Science.gov (United States)

    Lu, Hongjing; Rojas, Randall R; Beckers, Tom; Yuille, Alan L

    2016-03-01

    Two key research issues in the field of causal learning are how people acquire causal knowledge when observing data that are presented sequentially, and the level of abstraction at which learning takes place. Does sequential causal learning solely involve the acquisition of specific cause-effect links, or do learners also acquire knowledge about abstract causal constraints? Recent empirical studies have revealed that experience with one set of causal cues can dramatically alter subsequent learning and performance with entirely different cues, suggesting that learning involves abstract transfer, and such transfer effects involve sequential presentation of distinct sets of causal cues. It has been demonstrated that pre-training (or even post-training) can modulate classic causal learning phenomena such as forward and backward blocking. To account for these effects, we propose a Bayesian theory of sequential causal learning. The theory assumes that humans are able to consider and use several alternative causal generative models, each instantiating a different causal integration rule. Model selection is used to decide which integration rule to use in a given learning environment in order to infer causal knowledge from sequential data. Detailed computer simulations demonstrate that humans rely on the abstract characteristics of outcome variables (e.g., binary vs. continuous) to select a causal integration rule, which in turn alters causal learning in a variety of blocking and overshadowing paradigms. When the nature of the outcome variable is ambiguous, humans select the model that yields the best fit with the recent environment, and then apply it to subsequent learning tasks. Based on sequential patterns of cue-outcome co-occurrence, the theory can account for a range of phenomena in sequential causal learning, including various blocking effects, primacy effects in some experimental conditions, and apparently abstract transfer of causal knowledge. Copyright © 2015

  4. Impact of Diagrams on Recalling Sequential Elements in Expository Texts.

    Science.gov (United States)

    Guri-Rozenblit, Sarah

    1988-01-01

    Examines the instructional effectiveness of abstract diagrams on recall of sequential relations in social science textbooks. Concludes that diagrams assist significantly the recall of sequential relations in a text and decrease significantly the rate of order mistakes. (RS)

  5. Quantum Probability Zero-One Law for Sequential Terminal Events

    Science.gov (United States)

    Rehder, Wulf

    1980-07-01

    On the basis of the Jauch-Piron quantum probability calculus a zero-one law for sequential terminal events is proven, and the significance of certain crucial axioms in the quantum probability calculus is discussed. The result shows that the Jauch-Piron set of axioms is appropriate for the non-Boolean algebra of sequential events.

  6. A path-level exact parallelization strategy for sequential simulation

    Science.gov (United States)

    Peredo, Oscar F.; Baeza, Daniel; Ortiz, Julián M.; Herrero, José R.

    2018-01-01

    Sequential Simulation is a well known method in geostatistical modelling. Following the Bayesian approach for simulation of conditionally dependent random events, Sequential Indicator Simulation (SIS) method draws simulated values for K categories (categorical case) or classes defined by K different thresholds (continuous case). Similarly, Sequential Gaussian Simulation (SGS) method draws simulated values from a multivariate Gaussian field. In this work, a path-level approach to parallelize SIS and SGS methods is presented. A first stage of re-arrangement of the simulation path is performed, followed by a second stage of parallel simulation for non-conflicting nodes. A key advantage of the proposed parallelization method is to generate identical realizations as with the original non-parallelized methods. Case studies are presented using two sequential simulation codes from GSLIB: SISIM and SGSIM. Execution time and speedup results are shown for large-scale domains, with many categories and maximum kriging neighbours in each case, achieving high speedup results in the best scenarios using 16 threads of execution in a single machine.

  7. Concatenated coding system with iterated sequential inner decoding

    DEFF Research Database (Denmark)

    Jensen, Ole Riis; Paaske, Erik

    1995-01-01

    We describe a concatenated coding system with iterated sequential inner decoding. The system uses convolutional codes of very long constraint length and operates on iterations between an inner Fano decoder and an outer Reed-Solomon decoder......We describe a concatenated coding system with iterated sequential inner decoding. The system uses convolutional codes of very long constraint length and operates on iterations between an inner Fano decoder and an outer Reed-Solomon decoder...

  8. Drug injection into fat tissue with a laser based microjet injector

    Science.gov (United States)

    Han, Tae-hee; Hah, Jung-moo; Yoh, Jack J.

    2011-05-01

    We have investigated a new micro drug jet injector using laser pulse energy. An infrared laser beam of high energy (˜3 J/pulse) is focused inside a driving fluid in a small chamber. The pulse then induces various energy releasing processes, and generates fast microjets through a micronozzle. The elastic membrane of this system plays an important role in transferring mechanical pressure and protecting drug from heat release. In this paper, we offer the sequential images of microjet generation taken by a high speed camera as an evidence of the multiple injections via single pulse. Furthermore, we test the proposed system to penetrate soft animal tissues in order to evaluate its feasibility as an advanced transdermal drug delivery method.

  9. Automated model building

    CERN Document Server

    Caferra, Ricardo; Peltier, Nicholas

    2004-01-01

    This is the first book on automated model building, a discipline of automated deduction that is of growing importance Although models and their construction are important per se, automated model building has appeared as a natural enrichment of automated deduction, especially in the attempt to capture the human way of reasoning The book provides an historical overview of the field of automated deduction, and presents the foundations of different existing approaches to model construction, in particular those developed by the authors Finite and infinite model building techniques are presented The main emphasis is on calculi-based methods, and relevant practical results are provided The book is of interest to researchers and graduate students in computer science, computational logic and artificial intelligence It can also be used as a textbook in advanced undergraduate courses

  10. Sequential Markov chain Monte Carlo filter with simultaneous model selection for electrocardiogram signal modeling.

    Science.gov (United States)

    Edla, Shwetha; Kovvali, Narayan; Papandreou-Suppappola, Antonia

    2012-01-01

    Constructing statistical models of electrocardiogram (ECG) signals, whose parameters can be used for automated disease classification, is of great importance in precluding manual annotation and providing prompt diagnosis of cardiac diseases. ECG signals consist of several segments with different morphologies (namely the P wave, QRS complex and the T wave) in a single heart beat, which can vary across individuals and diseases. Also, existing statistical ECG models exhibit a reliance upon obtaining a priori information from the ECG data by using preprocessing algorithms to initialize the filter parameters, or to define the user-specified model parameters. In this paper, we propose an ECG modeling technique using the sequential Markov chain Monte Carlo (SMCMC) filter that can perform simultaneous model selection, by adaptively choosing from different representations depending upon the nature of the data. Our results demonstrate the ability of the algorithm to track various types of ECG morphologies, including intermittently occurring ECG beats. In addition, we use the estimated model parameters as the feature set to classify between ECG signals with normal sinus rhythm and four different types of arrhythmia.

  11. Histopathological Alterations after Single Epidural Injection of Ropivacaine, Methylprednizolone Acetate, or Contrast Material in Swine

    International Nuclear Information System (INIS)

    Kitsou, Maria-Chrysanthi; Kostopanagiotou, Georgia; Kalimeris, Konstantinos; Vlachodimitropoulos, Demetrios; Soultanis, Konstantinos; Batistaki, Chrysanthi; Kelekis, Alexis

    2011-01-01

    Purpose: The consequences from the injection of different types of drugs in the epidural space remains unknown. Increasing evidence suggests that localized inflammation, fibrosis, and arachnoiditis can complicate sequential epidural blockades, or even epidural contrast injection. We investigate the in vivo effect of epidural injections in the epidural space in an animal model. Materials and Methods: A group of ten male adult pigs, five punctures to each at distinct vertebral interspaces under general anesthesia, were examined, testing different drugs, used regularly in the epidural space (iopamidol, methylprednisolone acetate, ropivacaine). Each site was marked with a percutaneous hook wire marker. Histological analysis of the epidural space, the meninges, and the underlying spinal cord of the punctured sites along with staining for caspase-3 followed 20 days later. Results: The epidural space did not manifest adhesions or any other pathology, and the outer surface of the dura was not impaired in any specimen. The group that had the contrast media injection showed a higher inflammation response compared to the other groups (P = 0.001). Positive staining for caspase-3 was limited to <5% of neurons with all substances used. Conclusion: No proof of arachnoiditis and/or fibrosis was noted in the epidural space with the use of the above-described drugs. A higher inflammation rate was noted with the use of contrast media.

  12. Lineup Composition, Suspect Position, and the Sequential Lineup Advantage

    Science.gov (United States)

    Carlson, Curt A.; Gronlund, Scott D.; Clark, Steven E.

    2008-01-01

    N. M. Steblay, J. Dysart, S. Fulero, and R. C. L. Lindsay (2001) argued that sequential lineups reduce the likelihood of mistaken eyewitness identification. Experiment 1 replicated the design of R. C. L. Lindsay and G. L. Wells (1985), the first study to show the sequential lineup advantage. However, the innocent suspect was chosen at a lower rate…

  13. Trial Sequential Analysis in systematic reviews with meta-analysis

    Directory of Open Access Journals (Sweden)

    Jørn Wetterslev

    2017-03-01

    Full Text Available Abstract Background Most meta-analyses in systematic reviews, including Cochrane ones, do not have sufficient statistical power to detect or refute even large intervention effects. This is why a meta-analysis ought to be regarded as an interim analysis on its way towards a required information size. The results of the meta-analyses should relate the total number of randomised participants to the estimated required meta-analytic information size accounting for statistical diversity. When the number of participants and the corresponding number of trials in a meta-analysis are insufficient, the use of the traditional 95% confidence interval or the 5% statistical significance threshold will lead to too many false positive conclusions (type I errors and too many false negative conclusions (type II errors. Methods We developed a methodology for interpreting meta-analysis results, using generally accepted, valid evidence on how to adjust thresholds for significance in randomised clinical trials when the required sample size has not been reached. Results The Lan-DeMets trial sequential monitoring boundaries in Trial Sequential Analysis offer adjusted confidence intervals and restricted thresholds for statistical significance when the diversity-adjusted required information size and the corresponding number of required trials for the meta-analysis have not been reached. Trial Sequential Analysis provides a frequentistic approach to control both type I and type II errors. We define the required information size and the corresponding number of required trials in a meta-analysis and the diversity (D2 measure of heterogeneity. We explain the reasons for using Trial Sequential Analysis of meta-analysis when the actual information size fails to reach the required information size. We present examples drawn from traditional meta-analyses using unadjusted naïve 95% confidence intervals and 5% thresholds for statistical significance. Spurious conclusions in

  14. Heat accumulation during sequential cortical bone drilling.

    Science.gov (United States)

    Palmisano, Andrew C; Tai, Bruce L; Belmont, Barry; Irwin, Todd A; Shih, Albert; Holmes, James R

    2016-03-01

    Significant research exists regarding heat production during single-hole bone drilling. No published data exist regarding repetitive sequential drilling. This study elucidates the phenomenon of heat accumulation for sequential drilling with both Kirschner wires (K wires) and standard two-flute twist drills. It was hypothesized that cumulative heat would result in a higher temperature with each subsequent drill pass. Nine holes in a 3 × 3 array were drilled sequentially on moistened cadaveric tibia bone kept at body temperature (about 37 °C). Four thermocouples were placed at the center of four adjacent holes and 2 mm below the surface. A battery-driven hand drill guided by a servo-controlled motion system was used. Six samples were drilled with each tool (2.0 mm K wire and 2.0 and 2.5 mm standard drills). K wire drilling increased temperature from 5 °C at the first hole to 20 °C at holes 6 through 9. A similar trend was found in standard drills with less significant increments. The maximum temperatures of both tools increased from drill sizes was found to be insignificant (P > 0.05). In conclusion, heat accumulated during sequential drilling, with size difference being insignificant. K wire produced more heat than its twist-drill counterparts. This study has demonstrated the heat accumulation phenomenon and its significant effect on temperature. Maximizing the drilling field and reducing the number of drill passes may decrease bone injury. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  15. Direct microcomputer controlled determination of zinc in human serum by flow injection atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Simonsen, Kirsten Wiese; Nielsen, Bent; Jensen, Arne

    1986-01-01

    A procedure is described for the direct determination of zinc in human serum by fully automated, microcomputer controlled flow injection atomic absorption spectrometry (Fl-AAS). The Fl system is pumpless, using the negative pressure created by the nebuliser. It only consists of a three-way valve......, programmable from the microcomputer, to control the sample volume. No pre-treatment of the samples is necessary. The limit of detection is 0.14 mg l–1, and only small amounts of serum (

  16. Cost-effectiveness of simultaneous versus sequential surgery in head and neck reconstruction.

    Science.gov (United States)

    Wong, Kevin K; Enepekides, Danny J; Higgins, Kevin M

    2011-02-01

    To determine whether simultaneous (ablation and reconstruction overlaps by two teams) head and neck reconstruction is cost effective compared to sequentially (ablation followed by reconstruction) performed surgery. Case-controlled study. Tertiary care hospital. Oncology patients undergoing free flap reconstruction of the head and neck. A match paired comparison study was performed with a retrospective chart review examining the total time of surgery for sequential and simultaneous surgery. Nine patients were selected for both the sequential and simultaneous groups. Sequential head and neck reconstruction patients were pair matched with patients who had undergone similar oncologic ablative or reconstructive procedures performed in a simultaneous fashion. A detailed cost analysis using the microcosting method was then undertaken looking at the direct costs of the surgeons, anesthesiologist, operating room, and nursing. On average, simultaneous surgery required 3 hours 15 minutes less operating time, leading to a cost savings of approximately $1200/case when compared to sequential surgery. This represents approximately a 15% reduction in the cost of the entire operation. Simultaneous head and neck reconstruction is more cost effective when compared to sequential surgery.

  17. Media-fill simulation tests in manual and robotic aseptic preparation of injection solutions in syringes.

    Science.gov (United States)

    Krämer, Irene; Federici, Matteo; Kaiser, Vanessa; Thiesen, Judith

    2016-04-01

    The purpose of this study was to evaluate the contamination rate of media-fill products either prepared automated with a robotic system (APOTECAchemo™) or prepared manually at cytotoxic workbenches in the same cleanroom environment and by experienced operators. Media fills were completed by microbiological environmental control in the critical zones and used to validate the cleaning and disinfection procedures of the robotic system. The aseptic preparation of patient individual ready-to-use injection solutions was simulated by using double concentrated tryptic soy broth as growth medium, water for injection and plastic syringes as primary packaging materials. Media fills were either prepared automated (500 units) in the robot or manually (500 units) in cytotoxic workbenches in the same cleanroom over a period of 18 working days. The test solutions were incubated at room temperature (22℃) over 4 weeks. Products were visually inspected for turbidity after a 2-week and 4-week period. Following incubation, growth promotion tests were performed with Staphylococcus epidermidis. During the media-fill procedures, passive air monitoring was performed with settle plates and surface monitoring with contact plates on predefined locations as well as fingerprints. The plates got incubated for 5-7 days at room temperature, followed by 2-3 days at 30-35℃ and the colony forming units (cfu) counted after both periods. The robot was cleaned and disinfected according to the established standard operating procedure on two working days prior to the media-fill session, while on six other working days only six critical components were sanitized at the end of the media-fill sessions. Every day UV irradiation was operated for 4 h after finishing work. None of the 1000 media-fill products prepared in the two different settings showed turbidity after the incubation period thereby indicating no contamination with microorganisms. All products remained uniform, clear, and light

  18. 78 FR 53466 - Modification of Two National Customs Automation Program (NCAP) Tests Concerning Automated...

    Science.gov (United States)

    2013-08-29

    ... Customs Automation Program (NCAP) Tests Concerning Automated Commercial Environment (ACE) Document Image... National Customs Automation Program (NCAP) tests concerning document imaging, known as the Document Image... the National Customs Automation Program (NCAP) tests concerning document imaging, known as the...

  19. Dihydroazulene photoswitch operating in sequential tunneling regime

    DEFF Research Database (Denmark)

    Broman, Søren Lindbæk; Lara-Avila, Samuel; Thisted, Christine Lindbjerg

    2012-01-01

    to electrodes so that the electron transport goes by sequential tunneling. To assure weak coupling, the DHA switching kernel is modified by incorporating p-MeSC6H4 end-groups. Molecules are prepared by Suzuki cross-couplings on suitable halogenated derivatives of DHA. The synthesis presents an expansion of our......, incorporating a p-MeSC6H4 anchoring group in one end, has been placed in a silver nanogap. Conductance measurements justify that transport through both DHA (high resistivity) and VHF (low resistivity) forms goes by sequential tunneling. The switching is fairly reversible and reenterable; after more than 20 ON...

  20. A Trust-region-based Sequential Quadratic Programming Algorithm

    DEFF Research Database (Denmark)

    Henriksen, Lars Christian; Poulsen, Niels Kjølstad

    This technical note documents the trust-region-based sequential quadratic programming algorithm used in other works by the authors. The algorithm seeks to minimize a convex nonlinear cost function subject to linear inequalty constraints and nonlinear equality constraints.......This technical note documents the trust-region-based sequential quadratic programming algorithm used in other works by the authors. The algorithm seeks to minimize a convex nonlinear cost function subject to linear inequalty constraints and nonlinear equality constraints....

  1. Sequential search leads to faster, more efficient fragment-based de novo protein structure prediction.

    Science.gov (United States)

    de Oliveira, Saulo H P; Law, Eleanor C; Shi, Jiye; Deane, Charlotte M

    2018-04-01

    Most current de novo structure prediction methods randomly sample protein conformations and thus require large amounts of computational resource. Here, we consider a sequential sampling strategy, building on ideas from recent experimental work which shows that many proteins fold cotranslationally. We have investigated whether a pseudo-greedy search approach, which begins sequentially from one of the termini, can improve the performance and accuracy of de novo protein structure prediction. We observed that our sequential approach converges when fewer than 20 000 decoys have been produced, fewer than commonly expected. Using our software, SAINT2, we also compared the run time and quality of models produced in a sequential fashion against a standard, non-sequential approach. Sequential prediction produces an individual decoy 1.5-2.5 times faster than non-sequential prediction. When considering the quality of the best model, sequential prediction led to a better model being produced for 31 out of 41 soluble protein validation cases and for 18 out of 24 transmembrane protein cases. Correct models (TM-Score > 0.5) were produced for 29 of these cases by the sequential mode and for only 22 by the non-sequential mode. Our comparison reveals that a sequential search strategy can be used to drastically reduce computational time of de novo protein structure prediction and improve accuracy. Data are available for download from: http://opig.stats.ox.ac.uk/resources. SAINT2 is available for download from: https://github.com/sauloho/SAINT2. saulo.deoliveira@dtc.ox.ac.uk. Supplementary data are available at Bioinformatics online.

  2. Optimization of automation: III. Development of optimization method for determining automation rate in nuclear power plants

    International Nuclear Information System (INIS)

    Lee, Seung Min; Kim, Jong Hyun; Kim, Man Cheol; Seong, Poong Hyun

    2016-01-01

    Highlights: • We propose an appropriate automation rate that enables the best human performance. • We analyze the shortest working time considering Situation Awareness Recovery (SAR). • The optimized automation rate is estimated by integrating the automation and ostracism rate estimation methods. • The process to derive the optimized automation rate is demonstrated through case studies. - Abstract: Automation has been introduced in various industries, including the nuclear field, because it is commonly believed that automation promises greater efficiency, lower workloads, and fewer operator errors through reducing operator errors and enhancing operator and system performance. However, the excessive introduction of automation has deteriorated operator performance due to the side effects of automation, which are referred to as Out-of-the-Loop (OOTL), and this is critical issue that must be resolved. Thus, in order to determine the optimal level of automation introduction that assures the best human operator performance, a quantitative method of optimizing the automation is proposed in this paper. In order to propose the optimization method for determining appropriate automation levels that enable the best human performance, the automation rate and ostracism rate, which are estimation methods that quantitatively analyze the positive and negative effects of automation, respectively, are integrated. The integration was conducted in order to derive the shortest working time through considering the concept of situation awareness recovery (SAR), which states that the automation rate with the shortest working time assures the best human performance. The process to derive the optimized automation rate is demonstrated through an emergency operation scenario-based case study. In this case study, four types of procedures are assumed through redesigning the original emergency operating procedure according to the introduced automation and ostracism levels. Using the

  3. Transformational change: nurses substituting for ophthalmologists for intravitreal injections – a quality-improvement report

    Directory of Open Access Journals (Sweden)

    Michelotti MM

    2014-04-01

    Full Text Available Monica M Michelotti,1 Salwa Abugreen,2 Simon P Kelly,1 Jiten Morarji,1 Debra Myerscough,2 Tina Boddie,2 Ann Haughton,1 Natalie Nixon,2 Brenda Mason,1 Evangelos Sioras11Ophthalmology Department, Royal Bolton Hospital NHS Foundation Trust, Bolton, UK; 2Ophthalmology Department, East Lancashire NHS Trust, Blackburn, UKBackground: The dramatic increase in need for anti-vascular endothelial growth factor (anti-VEGF intravitreal therapy in the treatment of retinal disease and the absence of an equivalent increase in ophthalmologists to undertake such intravitreal injections created a patient-safety risk. Timing of intravitreal therapy (IVT is critical to prevent vision loss and local clinics lacked capacity to treat patients appropriately. We aimed to improve capacity for IVT by nurse injections.Materials and methods: A multidisciplinary prospective service-improvement process was undertaken at two adjacent general hospitals in the northwest of England. IVT injections by nurses were a principal component of solution development. After we had obtained appropriate institutional approval, experienced ophthalmic nurses were trained, supervised, and assessed to undertake IVT. Ophthalmologists directly supervised the first 200 injections, and a retina specialist was always on site.Results: Nurses undertook 3,355 intravitreal injections between June 2012 and November 2013, with minor adverse events (0.3% subconjunctival hemorrhage and corneal abrasion. There were no patient complaints at either hospital.Conclusion: Experienced ophthalmic nurses quickly learned how to perform such injections safely. IVT by nurses was well accepted by patients and staff. Hospital A trained three nurses sequentially for improved flexibility in scheduling. Novel use of appropriately trained nonmedical staff can improve efficiency and access in an overburdened service with time-sensitive disease. Retinal assessment was undertaken by ophthalmologists only. Improved access to IVT

  4. Flow analysis by using solenoid valves for As(III determination in natural waters by an on-line separation and pre-concentration system coupled to a tungsten coil atomizer

    Directory of Open Access Journals (Sweden)

    José Y. Neira

    2005-03-01

    Full Text Available A flow system coupled to a tungsten coil atomizer in an atomic absorption spectrometer (TCA-AAS was developed for As(III determination in waters, by extraction with sodium diethyldithiocarbamate (NaDDTC as complexing agent, and by sorption of the As(III-DDTC complex in a micro-column filled with 5 mg C18 reversed phase (10 µL dry sorbent, followed by elution with ethanol. A complete pre-concentration/elution cycle took 208 s, with 30 s sample load time (1.7 mL and 4 s elution time (71 µL. The interface and software for the synchronous control of two peristaltic pumps (RUN/ STOP, an autosampler arm, seven solenoid valves, one injection valve, the electrothermal atomizer and the spectrometer Read function were constructed. The system was characterized and validated by analytical recovery studies performed both in synthetic solutions and in natural waters. Using a 30 s pre-concentration period, the working curve was linear between 0.25 and 6.0 µg L-1 (r = 0.9976, the retention efficiency was 94±1% (6.0 µg L-1, and the pre-concentration coefficient was 28.9. The characteristic mass was 58 pg, the mean repeatability (expressed as the variation coefficient was 3.4% (n=5, the detection limit was 0.058 µg L-1 (4.1 pg in 71 µL of eluate injected into the coil, and the mean analytical recovery in natural waters was 92.6 ± 9.5 % (n=15. The procedure is simple, economic, less prone to sample loss and contamination and the useful lifetime of the micro-column was between 200-300 pre-concentration cycles.

  5. World-wide distribution automation systems

    International Nuclear Information System (INIS)

    Devaney, T.M.

    1994-01-01

    A worldwide power distribution automation system is outlined. Distribution automation is defined and the status of utility automation is discussed. Other topics discussed include a distribution management system, substation feeder, and customer functions, potential benefits, automation costs, planning and engineering considerations, automation trends, databases, system operation, computer modeling of system, and distribution management systems

  6. WIDAFELS flexible automation systems

    International Nuclear Information System (INIS)

    Shende, P.S.; Chander, K.P.; Ramadas, P.

    1990-01-01

    After discussing the various aspects of automation, some typical examples of various levels of automation are given. One of the examples is of automated production line for ceramic fuel pellets. (M.G.B.)

  7. Synthetic Aperture Sequential Beamforming

    DEFF Research Database (Denmark)

    Kortbek, Jacob; Jensen, Jørgen Arendt; Gammelmark, Kim Løkke

    2008-01-01

    A synthetic aperture focusing (SAF) technique denoted Synthetic Aperture Sequential Beamforming (SASB) suitable for 2D and 3D imaging is presented. The technique differ from prior art of SAF in the sense that SAF is performed on pre-beamformed data contrary to channel data. The objective is to im......A synthetic aperture focusing (SAF) technique denoted Synthetic Aperture Sequential Beamforming (SASB) suitable for 2D and 3D imaging is presented. The technique differ from prior art of SAF in the sense that SAF is performed on pre-beamformed data contrary to channel data. The objective...... is to improve and obtain a more range independent lateral resolution compared to conventional dynamic receive focusing (DRF) without compromising frame rate. SASB is a two-stage procedure using two separate beamformers. First a set of Bmode image lines using a single focal point in both transmit and receive...... is stored. The second stage applies the focused image lines from the first stage as input data. The SASB method has been investigated using simulations in Field II and by off-line processing of data acquired with a commercial scanner. The performance of SASB with a static image object is compared with DRF...

  8. Effect of short-term sequential administration of nonsteroidal anti-inflammatory drugs on the stomach and proximal portion of the duodenum in healthy dogs.

    Science.gov (United States)

    Dowers, Kristy L; Uhrig, Samantha R; Mama, Khursheed R; Gaynor, James S; Hellyer, Peter W

    2006-10-01

    To evaluate effects of injection with a nonsteroidal anti-inflammatory drug (NSAID) followed by oral administration of an NSAID on the gastrointestinal tract (GIT) of healthy dogs. 6 healthy Walker Hounds. In a randomized, crossover design, dogs were administered 4 treatments consisting of an SC injection of an NSAID or control solution (day 0), followed by oral administration of an NSAID or inert substance for 4 days (days 1 through 4). Treatment regimens included carprofen (4 mg/kg) followed by inert substance; saline (0.9% NaCl) solution followed by deracoxib (4 mg/kg); carprofen (4 mg/kg) followed by carprofen (4 mg/kg); and carprofen (4 mg/kg) followed by deracoxib (4 mg/kg). Hematologic, serum biochemical, and fecal evaluations were conducted weekly, and clinical scores were obtained daily. Endoscopy of the GIT was performed before and on days 1, 2, and 5 for each treatment. Lesions were scored by use of a 6-point scale. No significant differences existed for clinical data, clinicopathologic data, or lesion scores in the esophagus, cardia, or duodenum. For the gastric fundus, antrum, and lesser curvature, an effect of time was observed for all treatments, with lesions worsening from before to day 2 of treatments but improving by day 5. Sequential administration of NSAIDs in this experiment did not result in clinically important gastroduodenal ulcers. A larger study to investigate the effect of sequential administration of NSAIDs for longer durations and in dogs with signs of acute and chronic pain is essential to substantiate these findings.

  9. Evaluation Using Sequential Trials Methods.

    Science.gov (United States)

    Cohen, Mark E.; Ralls, Stephen A.

    1986-01-01

    Although dental school faculty as well as practitioners are interested in evaluating products and procedures used in clinical practice, research design and statistical analysis can sometimes pose problems. Sequential trials methods provide an analytical structure that is both easy to use and statistically valid. (Author/MLW)

  10. Attack Trees with Sequential Conjunction

    NARCIS (Netherlands)

    Jhawar, Ravi; Kordy, Barbara; Mauw, Sjouke; Radomirović, Sasa; Trujillo-Rasua, Rolando

    2015-01-01

    We provide the first formal foundation of SAND attack trees which are a popular extension of the well-known attack trees. The SAND at- tack tree formalism increases the expressivity of attack trees by intro- ducing the sequential conjunctive operator SAND. This operator enables the modeling of

  11. Semi-automated 86Y purification using a three-column system

    International Nuclear Information System (INIS)

    Park, Luke S.; Szajek, Lawrence P.; Wong, Karen J.; Plascjak, Paul S.; Garmestani, Kayhan; Googins, Shawn; Eckelman, William C.; Carrasquillo, Jorge A.; Paik, Chang H.

    2004-01-01

    The separation of 86 Y from 86 Sr was optimized by a semi-automated purification system involving the passage of the target sample through three sequential columns. The target material was dissolved in 4 N HNO 3 and loaded onto a Sr-selective (Sr-Spec) column to retain the 86 Sr. The yttrium was eluted with 4 N HNO 3 onto the second Y-selective (RE-Spec) column with quantitative retention. The RE-Spec column was eluted with a stepwise decreasing concentration of HNO 3 to wash out potential metallic impurities to a waste container. The eluate was then pumped onto an Aminex A5 column with 0.1 N HCl and finally with 3 N HCl to collect the radioyttrium in 0.6-0.8 mL with a >80% recovery. This method enabled us to decontaminate Sr by 250,000 times and label 30 μ g of DOTA-Biotin with a >95% yield

  12. Automation in Clinical Microbiology

    Science.gov (United States)

    Ledeboer, Nathan A.

    2013-01-01

    Historically, the trend toward automation in clinical pathology laboratories has largely bypassed the clinical microbiology laboratory. In this article, we review the historical impediments to automation in the microbiology laboratory and offer insight into the reasons why we believe that we are on the cusp of a dramatic change that will sweep a wave of automation into clinical microbiology laboratories. We review the currently available specimen-processing instruments as well as the total laboratory automation solutions. Lastly, we outline the types of studies that will need to be performed to fully assess the benefits of automation in microbiology laboratories. PMID:23515547

  13. Virtual automation.

    Science.gov (United States)

    Casis, E; Garrido, A; Uranga, B; Vives, A; Zufiaurre, C

    2001-01-01

    Total laboratory automation (TLA) can be substituted in mid-size laboratories by a computer sample workflow control (virtual automation). Such a solution has been implemented in our laboratory using PSM, software developed in cooperation with Roche Diagnostics (Barcelona, Spain), to this purpose. This software is connected to the online analyzers and to the laboratory information system and is able to control and direct the samples working as an intermediate station. The only difference with TLA is the replacement of transport belts by personnel of the laboratory. The implementation of this virtual automation system has allowed us the achievement of the main advantages of TLA: workload increase (64%) with reduction in the cost per test (43%), significant reduction in the number of biochemistry primary tubes (from 8 to 2), less aliquoting (from 600 to 100 samples/day), automation of functional testing, drastic reduction of preanalytical errors (from 11.7 to 0.4% of the tubes) and better total response time for both inpatients (from up to 48 hours to up to 4 hours) and outpatients (from up to 10 days to up to 48 hours). As an additional advantage, virtual automation could be implemented without hardware investment and significant headcount reduction (15% in our lab).

  14. The impact of eyewitness identifications from simultaneous and sequential lineups.

    Science.gov (United States)

    Wright, Daniel B

    2007-10-01

    Recent guidelines in the US allow either simultaneous or sequential lineups to be used for eyewitness identification. This paper investigates how potential jurors weight the probative value of the different outcomes from both of these types of lineups. Participants (n=340) were given a description of a case that included some exonerating and some incriminating evidence. There was either a simultaneous or a sequential lineup. Depending on the condition, an eyewitness chose the suspect, chose a filler, or made no identification. The participant had to judge the guilt of the suspect and decide whether to render a guilty verdict. For both simultaneous and sequential lineups an identification had a large effect,increasing the probability of a guilty verdict. There were no reliable effects detected between making no identification and identifying a filler. The effect sizes were similar for simultaneous and sequential lineups. These findings are important for judges and other legal professionals to know for trials involving lineup identifications.

  15. Automation of Test Cases for Web Applications : Automation of CRM Test Cases

    OpenAIRE

    Seyoum, Alazar

    2012-01-01

    The main theme of this project was to design a test automation framework for automating web related test cases. Automating test cases designed for testing a web interface provide a means of improving a software development process by shortening the testing phase in the software development life cycle. In this project an existing AutoTester framework and iMacros test automation tools were used. CRM Test Agent was developed to integrate AutoTester to iMacros and to enable the AutoTester,...

  16. Properties of simultaneous and sequential two-nucleon transfer

    International Nuclear Information System (INIS)

    Pinkston, W.T.; Satchler, G.R.

    1982-01-01

    Approximate forms of the first- and second-order distorted-wave Born amplitudes are used to study the overall structure, particularly the selection rules, of the amplitudes for simultaneous and sequential transfer of two nucleons. The role of the spin-state assumed for the intermediate deuterons in sequential (t, p) reactions is stressed. The similarity of one-step and two-step amplitudes for (α, d) reactions is exhibited, and the consequent absence of any obvious J-dependence in their interference is noted. (orig.)

  17. Sequential contrast-enhanced MR imaging of the penis.

    Science.gov (United States)

    Kaneko, K; De Mouy, E H; Lee, B E

    1994-04-01

    To determine the enhancement patterns of the penis at magnetic resonance (MR) imaging. Sequential contrast material-enhanced MR images of the penis in a flaccid state were obtained in 16 volunteers (12 with normal penile function and four with erectile dysfunction). Subjects with normal erectile function showed gradual and centrifugal enhancement of the corpora cavernosa, while those with erectile dysfunction showed poor enhancement with abnormal progression. Sequential contrast-enhanced MR imaging provides additional morphologic information for the evaluation of erectile dysfunction.

  18. Investigation on the micro injection molding process of an overmolded multi-material micro component

    DEFF Research Database (Denmark)

    Baruffi, Federico; Calaon, Matteo; Tosello, Guido

    and difficult assembly steps, being the plastic molded directly on a metal substrate. In this scenario, an investigation on the fully automated micro overmolding manufacturing technology of a three-material micro component for acoustic applications has been carried out. Preliminary experiments allowed......Micro injection molding (μIM) is one of the few technologies capable of meeting the increasing demand of complex shaped micro plastic parts. This process, combined with the overmolding technique, allows a fast and cost-efficient production of multi-material micro components, saving numerous...

  19. Automated Fuel Element Closure Welding System

    International Nuclear Information System (INIS)

    Wahlquist, D.R.

    1993-01-01

    The Automated Fuel Element Closure Welding System is a robotic device that will load and weld top end plugs onto nuclear fuel elements in a highly radioactive and inert gas environment. The system was developed at Argonne National Laboratory-West as part of the Fuel Cycle Demonstration. The welding system performs four main functions, it (1) injects a small amount of a xenon/krypton gas mixture into specific fuel elements, and (2) loads tiny end plugs into the tops of fuel element jackets, and (3) welds the end plugs to the element jackets, and (4) performs a dimensional inspection of the pre- and post-welded fuel elements. The system components are modular to facilitate remote replacement of failed parts. The entire system can be operated remotely in manual, semi-automatic, or fully automatic modes using a computer control system. The welding system is currently undergoing software testing and functional checkout

  20. Synthesizing genetic sequential logic circuit with clock pulse generator.

    Science.gov (United States)

    Chuang, Chia-Hua; Lin, Chun-Liang

    2014-05-28

    Rhythmic clock widely occurs in biological systems which controls several aspects of cell physiology. For the different cell types, it is supplied with various rhythmic frequencies. How to synthesize a specific clock signal is a preliminary but a necessary step to further development of a biological computer in the future. This paper presents a genetic sequential logic circuit with a clock pulse generator based on a synthesized genetic oscillator, which generates a consecutive clock signal whose frequency is an inverse integer multiple to that of the genetic oscillator. An analogous electronic waveform-shaping circuit is constructed by a series of genetic buffers to shape logic high/low levels of an oscillation input in a basic sinusoidal cycle and generate a pulse-width-modulated (PWM) output with various duty cycles. By controlling the threshold level of the genetic buffer, a genetic clock pulse signal with its frequency consistent to the genetic oscillator is synthesized. A synchronous genetic counter circuit based on the topology of the digital sequential logic circuit is triggered by the clock pulse to synthesize the clock signal with an inverse multiple frequency to the genetic oscillator. The function acts like a frequency divider in electronic circuits which plays a key role in the sequential logic circuit with specific operational frequency. A cascaded genetic logic circuit generating clock pulse signals is proposed. Based on analogous implement of digital sequential logic circuits, genetic sequential logic circuits can be constructed by the proposed approach to generate various clock signals from an oscillation signal.

  1. Automation in trace-element chemistry - Development of a fully automated on-line preconcentration device for trace analysis of heavy metals with atomic spectroscopy

    International Nuclear Information System (INIS)

    Michaelis, M.R.A.

    1990-01-01

    Scope of this work was the development of an automated system for trace element preconcentration to be used and integrated to analytic atomic spectroscopic methods like flame atomic absorption spectrometry (FAAS), graphite furnace atomic absorption spectrometry (GFAAS) or atomic emission spectroscopy with inductively coupled plasma (ICP-AES). Based on the newly developed cellulose-based chelating cation exchangers ethylene-diamin-triacetic acid cellulose (EDTrA-Cellulose) and sulfonated-oxine cellulose a flexible, computer-controlled instrument for automation of preconcentration and/or of matrix separation of heavy metals is described. The most important properties of these materials are fast exchange kinetics, good selectivity against alkaline and alkaline earth elements, good flow characteristics and good stability of the material and the chelating functions against changes in pH-values of reagents necessary in the process. The combination of the preconcentration device for on-line determinations of Zn, Cd, Pb, Ni, Fe, Co, Mn, V, Cu, La, U, Th is described for FAAS and for ICP-AES with a simultaneous spectrometer. Signal enhancement factors of 70 are achieved from preconcentration of 10 ml and on-line determination with FAAS due to signal quantification in peak-height mode. For GFAAS and for sequential ICP methods for off-line preconcentration are given. The optimization and adaption of the interface to the different characteristics of the analytical instrumentation is emphasized. For evaluation and future developments with respect to determination and/or preconcentration of anionic species like As, Se, Sb etc. instrument modifications are proposed and a development software is described. (Author)

  2. Sequential weak continuity of null Lagrangians at the boundary

    Czech Academy of Sciences Publication Activity Database

    Kalamajska, A.; Kraemer, S.; Kružík, Martin

    2014-01-01

    Roč. 49, 3/4 (2014), s. 1263-1278 ISSN 0944-2669 R&D Projects: GA ČR GAP201/10/0357 Institutional support: RVO:67985556 Keywords : null Lagrangians * nonhomogeneous nonlinear mappings * sequential weak/in measure continuity Subject RIV: BA - General Mathematics Impact factor: 1.518, year: 2014 http://library.utia.cas.cz/separaty/2013/MTR/kruzik-sequential weak continuity of null lagrangians at the boundary.pdf

  3. An Automation Planning Primer.

    Science.gov (United States)

    Paynter, Marion

    1988-01-01

    This brief planning guide for library automation incorporates needs assessment and evaluation of options to meet those needs. A bibliography of materials on automation planning and software reviews, library software directories, and library automation journals is included. (CLB)

  4. Automation in Immunohematology

    Directory of Open Access Journals (Sweden)

    Meenu Bajpai

    2012-01-01

    Full Text Available There have been rapid technological advances in blood banking in South Asian region over the past decade with an increasing emphasis on quality and safety of blood products. The conventional test tube technique has given way to newer techniques such as column agglutination technique, solid phase red cell adherence assay, and erythrocyte-magnetized technique. These new technologies are adaptable to automation and major manufacturers in this field have come up with semi and fully automated equipments for immunohematology tests in the blood bank. Automation improves the objectivity and reproducibility of tests. It reduces human errors in patient identification and transcription errors. Documentation and traceability of tests, reagents and processes and archiving of results is another major advantage of automation. Shifting from manual methods to automation is a major undertaking for any transfusion service to provide quality patient care with lesser turnaround time for their ever increasing workload. This article discusses the various issues involved in the process.

  5. Sequential and simultaneous SLAR block adjustment. [spline function analysis for mapping

    Science.gov (United States)

    Leberl, F.

    1975-01-01

    Two sequential methods of planimetric SLAR (Side Looking Airborne Radar) block adjustment, with and without splines, and three simultaneous methods based on the principles of least squares are evaluated. A limited experiment with simulated SLAR images indicates that sequential block formation with splines followed by external interpolative adjustment is superior to the simultaneous methods such as planimetric block adjustment with similarity transformations. The use of the sequential block formation is recommended, since it represents an inexpensive tool for satisfactory point determination from SLAR images.

  6. Automated Budget System -

    Data.gov (United States)

    Department of Transportation — The Automated Budget System (ABS) automates management and planning of the Mike Monroney Aeronautical Center (MMAC) budget by providing enhanced capability to plan,...

  7. Bioprocessing automation in cell therapy manufacturing: Outcomes of special interest group automation workshop.

    Science.gov (United States)

    Ball, Oliver; Robinson, Sarah; Bure, Kim; Brindley, David A; Mccall, David

    2018-04-01

    Phacilitate held a Special Interest Group workshop event in Edinburgh, UK, in May 2017. The event brought together leading stakeholders in the cell therapy bioprocessing field to identify present and future challenges and propose potential solutions to automation in cell therapy bioprocessing. Here, we review and summarize discussions from the event. Deep biological understanding of a product, its mechanism of action and indication pathogenesis underpin many factors relating to bioprocessing and automation. To fully exploit the opportunities of bioprocess automation, therapeutics developers must closely consider whether an automation strategy is applicable, how to design an 'automatable' bioprocess and how to implement process modifications with minimal disruption. Major decisions around bioprocess automation strategy should involve all relevant stakeholders; communication between technical and business strategy decision-makers is of particular importance. Developers should leverage automation to implement in-process testing, in turn applicable to process optimization, quality assurance (QA)/ quality control (QC), batch failure control, adaptive manufacturing and regulatory demands, but a lack of precedent and technical opportunities can complicate such efforts. Sparse standardization across product characterization, hardware components and software platforms is perceived to complicate efforts to implement automation. The use of advanced algorithmic approaches such as machine learning may have application to bioprocess and supply chain optimization. Automation can substantially de-risk the wider supply chain, including tracking and traceability, cryopreservation and thawing and logistics. The regulatory implications of automation are currently unclear because few hardware options exist and novel solutions require case-by-case validation, but automation can present attractive regulatory incentives. Copyright © 2018 International Society for Cellular Therapy

  8. Establish an automated flow injection ESI-MS method for the screening of fragment based libraries: Application to Hsp90.

    Science.gov (United States)

    Riccardi Sirtori, Federico; Caronni, Dannica; Colombo, Maristella; Dalvit, Claudio; Paolucci, Mauro; Regazzoni, Luca; Visco, Carlo; Fogliatto, Gianpaolo

    2015-08-30

    ESI-MS is a well established technique for the study of biopolymers (nucleic acids, proteins) and their non covalent adducts, due to its capacity to detect ligand-target complexes in the gas phase and allows inference of ligand-target binding in solution. In this article we used this approach to investigate the interaction of ligands to the Heat Shock Protein 90 (Hsp90). This enzyme is a molecular chaperone involved in the folding and maturation of several proteins which has been subjected in the last years to intensive drug discovery efforts due to its key role in cancer. In particular, reference compounds, with a broad range of dissociation constants from 40pM to 100μM, were tested to assess the reliability of ESI-MS for the study of protein-ligand complexes. A good agreement was found between the values measured with a fluorescence polarization displacement assay and those determined by mass spectrometry. After this validation step we describe the setup of a medium throughput screening method, based on ESI-MS, suitable to explore interactions of therapeutic relevance biopolymers with chemical libraries. Our approach is based on an automated flow injection ESI-MS method (AFI-MS) and has been applied to screen the Nerviano Medical Sciences proprietary fragment library of about 2000 fragments against Hsp90. In order to discard false positive hits and to discriminate those of them interacting with the N-terminal ATP binding site, competition experiments were performed using a reference inhibitor. Gratifyingly, this group of hits matches with the ligands previously identified by NMR FAXS techniques and confirmed by X-ray co-crystallization experiments. These results support the use of AFI-MS for the screening of medium size libraries, including libraries of small molecules with low affinity typically used in fragment based drug discovery. AFI-MS is a valid alternative to other techniques with the additional opportunities to identify compounds interacting with

  9. Sequential Extraction Versus Comprehensive Characterization of Heavy Metal Species in Brownfield Soils

    Energy Technology Data Exchange (ETDEWEB)

    Dahlin, Cheryl L.; Williamson, Connie A.; Collins, W. Keith; Dahlin, David C.

    2002-06-01

    The applicability of sequential extraction as a means to determine species of heavy-metals was examined by a study on soil samples from two Superfund sites: the National Lead Company site in Pedricktown, NJ, and the Roebling Steel, Inc., site in Florence, NJ. Data from a standard sequential extraction procedure were compared to those from a comprehensive study that combined optical- and scanning-electron microscopy, X-ray diffraction, and chemical analyses. The study shows that larger particles of contaminants, encapsulated contaminants, and/or man-made materials such as slags, coke, metals, and plastics are subject to incasement, non-selectivity, and redistribution in the sequential extraction process. The results indicate that standard sequential extraction procedures that were developed for characterizing species of contaminants in river sediments may be unsuitable for stand-alone determinative evaluations of contaminant species in industrial-site materials. However, if employed as part of a comprehensive, site-specific characterization study, sequential extraction could be a very useful tool.

  10. Imitation of the sequential structure of actions by chimpanzees (Pan troglodytes).

    Science.gov (United States)

    Whiten, A

    1998-09-01

    Imitation was studied experimentally by allowing chimpanzees (Pan troglodytes) to observe alternative patterns of actions for opening a specially designed "artificial fruit." Like problematic foods primates deal with naturally, with the test fruit several defenses had to be removed to gain access to an edible core, but the sequential order and method of defense removal could be systematically varied. Each subject repeatedly observed 1 of 2 alternative techniques for removing each defense and 1 of 2 alternative sequential patterns of defense removal. Imitation of sequential organization emerged after repeated cycles of demonstration and attempts at opening the fruit. Imitation in chimpanzees may thus have some power to produce cultural convergence, counter to the supposition that individual learning processes corrupt copied actions. Imitation of sequential organization was accompanied by imitation of some aspects of the techniques that made up the sequence.

  11. Comparison of periodontal ligament injection and inferior alveolar nerve block in mandibular primary molars pulpotomy: a randomized control trial.

    Science.gov (United States)

    Haghgoo, Roza; Taleghani, Ferial

    2015-05-01

    Inferior alveolar nerve block is a common technique for anesthesia of the primary mandibular molars. A number of disadvantages have been shown to be associated with this technique. Periodontal ligament (PDL) injection could be considered as an alternative to inferior alveolar nerve block. The aim of this study was to evaluate the effectiveness of PDL injection in the anesthesia of primary molar pulpotomy with mandibular block. This study was performed using a sequential double-blind randomized trial design. 80 children aged 3-7 years old who required pulpotomy in symmetrical mandibular primary molars were selected. The teeth of these children were anesthetized with periodontal injection on one side of the mandible and block on the other. Pulpotomy was performed on each patient during the same appointment. Signs of discomfort, including hand and body tension and eye movement, the verbal complaint and crying (SEM scale), were evaluated by a dental assistant who was blinded to the treatment allocation of the patients. Finally, the data were analyzed using the exact Fisher test and Pearson Chi-squared exact test. Success rate was 88/75 and 91/25 in the PDL injection and nerve block groups, respectively. There was no statistically significant difference between the two techniques (P = 0.250). Results showed that PDL injection can be used as an alternative to nerve block in pulpotomy of the mandibular primary molars.

  12. Reorganization of large-scale cognitive networks during automation of imagination of a complex sequential movement.

    Science.gov (United States)

    Sauvage, C; De Greef, N; Manto, M; Jissendi, P; Nioche, C; Habas, C

    2015-04-01

    We investigated the functional reconfiguration of the cerebral networks involved in imagination of sequential movements of the left foot, both performed at regular and fast speed after mental imagery training. Thirty-five volunteers were scanned with a 3T MRI while they imagined a sequence of ankle movements (dorsiflexion, plantar flexion, varus and valgus) before and after mental practice. Subjects were distributed in two groups: the first group executed regular movements whereas the second group made fast movements. We applied the general linear model (GLM) and model-free, exploratory tensorial independent component analytic (TICA) approaches to identify plastic post-training effects on brain activation. GLM showed that post-training imagination of movement was accompanied by a dual effect: a specific recruitment of a medial prefronto-cingulo-parietal circuit reminiscent of the default-mode network, with the left putamen, and a decreased activity of a lateral fronto-parietal network. Training-related subcortical changes only consisted in an increased activity in the left striatum. Unexpectedly, no difference was observed in the cerebellum. TICA also revealed involvement of the left executive network, and of the dorsal control executive network but no significant differences were found between pre- and post-training phases. Therefore, repetitive motor mental imagery induced specific putamen (motor rehearsal) recruitment that one previously observed during learning of overt movements, and, simultaneously, a specific shift of activity from the dorsolateral prefrontal cortex (attention, working memory) to the medial posterior parietal and cingulate cortices (mental imagery and memory rehearsal). Our data complement and confirm the notion that differential and coupled recruitment of cognitive networks can constitute a neural marker of training effects. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  13. Coupling surfactants with permanganate for DNAPL removal : coinjection or sequential application as delivery methods

    Energy Technology Data Exchange (ETDEWEB)

    Dugan, P.J. [Carus Corp., Peru, IL (United States); Siegrist, R.L. [Colorado School of Mines, Golden, CO (United States); Crimi, M.L. [Clarkson Univ., Potsdam, NY (United States)

    2010-07-01

    This PowerPoint presentation described a study conducted to test the effectiveness of surfactant-enhanced permanganate for the remediation of dense nonaqueous phase liquids (DNAPL). When DNAPL enters the environment, it can pollute millions of gallons of ground water and create huge dissolved plumes that act as long-term sources of contamination. Surfactants were used to enhance the solubilization and mobilization of DNAPL during the remediation process. In situ chemical oxidation (ISCO) was then used to deliver oxidants into the sub-surface to destroy organic contaminants in the soil and ground water. Experimental 2-D flow-through cell studies of 72 surfactants were conducted with the permanganate to evaluate delivery methods and determine compatible co-solvents for the surfactant process. Delivery methods included co-injection and sequential application. Four compatible surfactants were found to be compatible with the permanganate. A 90 percent DNAPL remediation rate was achieved using relatively low surfactant and oxidant concentrations. tabs., figs.

  14. Non-injection Drug Use and Injection Initiation Assistance among People Who Inject Drugs in Tijuana, Mexico.

    Science.gov (United States)

    Ben Hamida, Amen; Rafful, Claudia; Jain, Sonia; Sun, Shelly; Gonzalez-Zuniga, Patricia; Rangel, Gudelia; Strathdee, Steffanie A; Werb, Dan

    2018-02-01

    Although most people who inject drugs (PWID) report receiving assistance during injection initiation events, little research has focused on risk factors among PWID for providing injection initiation assistance. We therefore sought to determine the influence of non-injection drug use among PWID on their risk to initiate others. We used generalized estimating equation (GEE) models on longitudinal data among a prospective cohort of PWID in Tijuana, Mexico (Proyecto El Cuete IV), while controlling for potential confounders. At baseline, 534 participants provided data on injection initiation assistance. Overall, 14% reported ever initiating others, with 4% reporting this behavior recently (i.e., in the past 6 months). In a multivariable GEE model, recent non-injection drug use was independently associated with providing injection initiation assistance (adjusted odds ratio [AOR] = 2.42, 95% confidence interval [CI] = 1.39-4.20). Further, in subanalyses examining specific drug types, recent non-injection use of cocaine (AOR = 9.31, 95% CI = 3.98-21.78), heroin (AOR = 4.00, 95% CI = 1.88-8.54), and methamphetamine (AOR = 2.03, 95% CI = 1.16-3.55) were all significantly associated with reporting providing injection initiation assistance. Our findings may have important implications for the development of interventional approaches to reduce injection initiation and related harms. Further research is needed to validate findings and inform future approaches to preventing entry into drug injecting.

  15. Sequential determination of important ecotoxic radionuclides in nuclear waste samples

    International Nuclear Information System (INIS)

    Bilohuscin, J.

    2016-01-01

    In the dissertation thesis we focused on the development and optimization of a sequential determination method for radionuclides 93 Zr, 94 Nb, 99 Tc and 126 Sn, employing extraction chromatography sorbents TEVA (R) Resin and Anion Exchange Resin, supplied by Eichrom Industries. Prior to the attestation of sequential separation of these proposed radionuclides from radioactive waste samples, a unique sequential procedure of 90 Sr, 239 Pu, 241 Am separation from urine matrices was tried, using molecular recognition sorbents of AnaLig (R) series and extraction chromatography sorbent DGA (R) Resin. On these experiments, four various sorbents were continually used for separation, including PreFilter Resin sorbent, which removes interfering organic materials present in raw urine. After the acquisition of positive results of this sequential procedure followed experiments with a 126 Sn separation using TEVA (R) Resin and Anion Exchange Resin sorbents. Radiochemical recoveries obtained from samples of radioactive evaporate concentrates and sludge showed high efficiency of the separation, while values of 126 Sn were under the minimum detectable activities MDA. Activity of 126 Sn was determined after ingrowth of daughter nuclide 126m Sb on HPGe gamma detector, with minimal contamination of gamma interfering radionuclides with decontamination factors (D f ) higher then 1400 for 60 Co and 47000 for 137 Cs. Based on the acquired experiments and results of these separation procedures, a complex method of sequential separation of 93 Zr, 94 Nb, 99 Tc and 126 Sn was proposed, which included optimization steps similar to those used in previous parts of the dissertation work. Application of the sequential separation method for sorbents TEVA (R) Resin and Anion Exchange Resin on real samples of radioactive wastes provided satisfactory results and an economical, time sparing, efficient method. (author)

  16. Injection, injectivity and injectability in geothermal operations: problems and possible solutions. Phase I. Definition of the problems

    Energy Technology Data Exchange (ETDEWEB)

    Vetter, O.J.; Crichlow, H.B.

    1979-02-14

    The following topics are covered: thermodynamic instability of brine, injectivity loss during regular production and injection operations, injectivity loss caused by measures other than regular operations, heat mining and associated reservoir problems in reinjection, pressure maintenance through imported make-up water, suggested solutions to injection problems, and suggested solutions to injection problems: remedial and stimulation measures. (MHR)

  17. A solution for automatic parallelization of sequential assembly code

    Directory of Open Access Journals (Sweden)

    Kovačević Đorđe

    2013-01-01

    Full Text Available Since modern multicore processors can execute existing sequential programs only on a single core, there is a strong need for automatic parallelization of program code. Relying on existing algorithms, this paper describes one new software solution tool for parallelization of sequential assembly code. The main goal of this paper is to develop the parallelizator which reads sequential assembler code and at the output provides parallelized code for MIPS processor with multiple cores. The idea is the following: the parser translates assembler input file to program objects suitable for further processing. After that the static single assignment is done. Based on the data flow graph, the parallelization algorithm separates instructions on different cores. Once sequential code is parallelized by the parallelization algorithm, registers are allocated with the algorithm for linear allocation, and the result at the end of the program is distributed assembler code on each of the cores. In the paper we evaluate the speedup of the matrix multiplication example, which was processed by the parallelizator of assembly code. The result is almost linear speedup of code execution, which increases with the number of cores. The speed up on the two cores is 1.99, while on 16 cores the speed up is 13.88.

  18. Documentscape: Intertextuality, Sequentiality & Autonomy at Work

    DEFF Research Database (Denmark)

    Christensen, Lars Rune; Bjørn, Pernille

    2014-01-01

    On the basis of an ethnographic field study, this article introduces the concept of documentscape to the analysis of document-centric work practices. The concept of documentscape refers to the entire ensemble of documents in their mutual intertextual interlocking. Providing empirical data from...... a global software development case, we show how hierarchical structures and sequentiality across the interlocked documents are critical to how actors make sense of the work of others and what to do next in a geographically distributed setting. Furthermore, we found that while each document is created...... as part of a quasi-sequential order, this characteristic does not make the document, as a single entity, into a stable object. Instead, we found that the documents were malleable and dynamic while suspended in intertextual structures. Our concept of documentscape points to how the hierarchical structure...

  19. 78 FR 66039 - Modification of National Customs Automation Program Test Concerning Automated Commercial...

    Science.gov (United States)

    2013-11-04

    ... Customs Automation Program Test Concerning Automated Commercial Environment (ACE) Cargo Release (Formerly...) plan to both rename and modify the National Customs Automation Program (NCAP) test concerning the... data elements required to obtain release for cargo transported by air. The test will now be known as...

  20. Automation-aided Task Loads Index based on the Automation Rate Reflecting the Effects on Human Operators in NPPs

    International Nuclear Information System (INIS)

    Lee, Seungmin; Seong, Poonghyun; Kim, Jonghyun

    2013-01-01

    Many researchers have found that a high automation rate does not guarantee high performance. Therefore, to reflect the effects of automation on human performance, a new estimation method of the automation rate that considers the effects of automation on human operators in nuclear power plants (NPPs) was suggested. These suggested measures express how much automation support human operators but it cannot express the change of human operators' workload, whether the human operators' workload is increased or decreased. Before considering automation rates, whether the adopted automation is good or bad might be estimated in advance. In this study, to estimate the appropriateness of automation according to the change of the human operators' task loads, automation-aided task loads index is suggested based on the concept of the suggested automation rate. To insure plant safety and efficiency on behalf of human operators, various automation systems have been installed in NPPs, and many works which were previously conducted by human operators can now be supported by computer-based operator aids. According to the characteristics of the automation types, the estimation method of the system automation and the cognitive automation rate were suggested. The proposed estimation method concentrates on the effects of introducing automation, so it directly express how much the automated system support human operators. Based on the suggested automation rates, the way to estimate how much the automated system can affect the human operators' cognitive task load is suggested in this study. When there is no automation, the calculated index is 1, and it means there is no change of human operators' task load

  1. Asleep at the automated wheel-Sleepiness and fatigue during highly automated driving.

    Science.gov (United States)

    Vogelpohl, Tobias; Kühn, Matthias; Hummel, Thomas; Vollrath, Mark

    2018-03-20

    Due to the lack of active involvement in the driving situation and due to monotonous driving environments drivers with automation may be prone to become fatigued faster than manual drivers (e.g. Schömig et al., 2015). However, little is known about the progression of fatigue during automated driving and its effects on the ability to take back manual control after a take-over request. In this driving simulator study with Nö=ö60 drivers we used a three factorial 2ö×ö2ö×ö12 mixed design to analyze the progression (12ö×ö5ömin; within subjects) of driver fatigue in drivers with automation compared to manual drivers (between subjects). Driver fatigue was induced as either mainly sleep related or mainly task related fatigue (between subjects). Additionally, we investigated the drivers' reactions to a take-over request in a critical driving scenario to gain insights into the ability of fatigued drivers to regain manual control and situation awareness after automated driving. Drivers in the automated driving condition exhibited facial indicators of fatigue after 15 to 35ömin of driving. Manual drivers only showed similar indicators of fatigue if they suffered from a lack of sleep and then only after a longer period of driving (approx. 40ömin). Several drivers in the automated condition closed their eyes for extended periods of time. In the driving with automation condition mean automation deactivation times after a take-over request were slower for a certain percentage (about 30%) of the drivers with a lack of sleep (Mö=ö3.2; SDö=ö2.1ös) compared to the reaction times after a long drive (Mö=ö2.4; SDö=ö0.9ös). Drivers with automation also took longer than manual drivers to first glance at the speed display after a take-over request and were more likely to stay behind a braking lead vehicle instead of overtaking it. Drivers are unable to stay alert during extended periods of automated driving without non-driving related tasks. Fatigued drivers could

  2. Procedure automation: the effect of automated procedure execution on situation awareness and human performance

    International Nuclear Information System (INIS)

    Andresen, Gisle; Svengren, Haakan; Heimdal, Jan O.; Nilsen, Svein; Hulsund, John-Einar; Bisio, Rossella; Debroise, Xavier

    2004-04-01

    As advised by the procedure workshop convened in Halden in 2000, the Halden Project conducted an experiment on the effect of automation of Computerised Procedure Systems (CPS) on situation awareness and human performance. The expected outcome of the study was to provide input for guidance on CPS design, and to support the Halden Project's ongoing research on human reliability analysis. The experiment was performed in HAMMLAB using the HAMBO BWR simulator and the COPMA-III CPS. Eight crews of operators from Forsmark 3 and Oskarshamn 3 participated. Three research questions were investigated: 1) Does procedure automation create Out-Of-The-Loop (OOTL) performance problems? 2) Does procedure automation affect situation awareness? 3) Does procedure automation affect crew performance? The independent variable, 'procedure configuration', had four levels: paper procedures, manual CPS, automation with breaks, and full automation. The results showed that the operators experienced OOTL problems in full automation, but that situation awareness and crew performance (response time) were not affected. One possible explanation for this is that the operators monitored the automated procedure execution conscientiously, something which may have prevented the OOTL problems from having negative effects on situation awareness and crew performance. In a debriefing session, the operators clearly expressed their dislike for the full automation condition, but that automation with breaks could be suitable for some tasks. The main reason why the operators did not like the full automation was that they did not feel being in control. A qualitative analysis addressing factors contributing to response time delays revealed that OOTL problems did not seem to cause delays, but that some delays could be explained by the operators having problems with the freeze function of the CPS. Also other factors such as teamwork and operator tendencies were of importance. Several design implications were drawn

  3. Instrument Control (iC) - An Open-Source Software to Automate Test Equipment.

    Science.gov (United States)

    Pernstich, K P

    2012-01-01

    It has become common practice to automate data acquisition from programmable instrumentation, and a range of different software solutions fulfill this task. Many routine measurements require sequential processing of certain tasks, for instance to adjust the temperature of a sample stage, take a measurement, and repeat that cycle for other temperatures. This paper introduces an open-source Java program that processes a series of text-based commands that define the measurement sequence. These commands are in an intuitive format which provides great flexibility and allows quick and easy adaptation to various measurement needs. For each of these commands, the iC-framework calls a corresponding Java method that addresses the specified instrument to perform the desired task. The functionality of iC can be extended with minimal programming effort in Java or Python, and new measurement equipment can be addressed by defining new commands in a text file without any programming.

  4. Sequential series for nuclear reactions

    International Nuclear Information System (INIS)

    Izumo, Ko

    1975-01-01

    A new time-dependent treatment of nuclear reactions is given, in which the wave function of compound nucleus is expanded by a sequential series of the reaction processes. The wave functions of the sequential series form another complete set of compound nucleus at the limit Δt→0. It is pointed out that the wave function is characterized by the quantities: the number of degrees of freedom of motion n, the period of the motion (Poincare cycle) tsub(n), the delay time t sub(nμ) and the relaxation time tausub(n) to the equilibrium of compound nucleus, instead of the usual quantum number lambda, the energy eigenvalue Esub(lambda) and the total width GAMMAsub(lambda) of resonance levels, respectively. The transition matrix elements and the yields of nuclear reactions also become the functions of time given by the Fourier transform of the usual ones. The Poincare cycles of compound nuclei are compared with the observed correlations among resonance levels, which are about 10 -17 --10 -16 sec for medium and heavy nuclei and about 10 -20 sec for the intermediate resonances. (auth.)

  5. Process automation using combinations of process and machine control technologies with application to a continuous dissolver

    International Nuclear Information System (INIS)

    Spencer, B.B.; Yarbro, O.O.

    1991-01-01

    Operation of a continuous rotary dissolver, designed to leach uranium-plutonium fuel from chopped sections of reactor fuel cladding using nitric acid, has been automated. The dissolver is a partly continuous, partly batch process that interfaces at both ends with batchwise processes, thereby requiring synchronization of certain operations. Liquid acid is fed and flows through the dissolver continuously, whereas chopped fuel elements are fed to the dissolver in small batches and move through the compartments of the dissolver stagewise. Sequential logic (or machine control) techniques are used to control discrete activities such as the sequencing of isolation valves. Feedback control is used to control acid flowrates and temperatures. Expert systems technology is used for on-line material balances and diagnostics of process operation. 1 ref., 3 figs

  6. A node linkage approach for sequential pattern mining.

    Directory of Open Access Journals (Sweden)

    Osvaldo Navarro

    Full Text Available Sequential Pattern Mining is a widely addressed problem in data mining, with applications such as analyzing Web usage, examining purchase behavior, and text mining, among others. Nevertheless, with the dramatic increase in data volume, the current approaches prove inefficient when dealing with large input datasets, a large number of different symbols and low minimum supports. In this paper, we propose a new sequential pattern mining algorithm, which follows a pattern-growth scheme to discover sequential patterns. Unlike most pattern growth algorithms, our approach does not build a data structure to represent the input dataset, but instead accesses the required sequences through pseudo-projection databases, achieving better runtime and reducing memory requirements. Our algorithm traverses the search space in a depth-first fashion and only preserves in memory a pattern node linkage and the pseudo-projections required for the branch being explored at the time. Experimental results show that our new approach, the Node Linkage Depth-First Traversal algorithm (NLDFT, has better performance and scalability in comparison with state of the art algorithms.

  7. Sequential Change-Point Detection via Online Convex Optimization

    Directory of Open Access Journals (Sweden)

    Yang Cao

    2018-02-01

    Full Text Available Sequential change-point detection when the distribution parameters are unknown is a fundamental problem in statistics and machine learning. When the post-change parameters are unknown, we consider a set of detection procedures based on sequential likelihood ratios with non-anticipating estimators constructed using online convex optimization algorithms such as online mirror descent, which provides a more versatile approach to tackling complex situations where recursive maximum likelihood estimators cannot be found. When the underlying distributions belong to a exponential family and the estimators satisfy the logarithm regret property, we show that this approach is nearly second-order asymptotically optimal. This means that the upper bound for the false alarm rate of the algorithm (measured by the average-run-length meets the lower bound asymptotically up to a log-log factor when the threshold tends to infinity. Our proof is achieved by making a connection between sequential change-point and online convex optimization and leveraging the logarithmic regret bound property of online mirror descent algorithm. Numerical and real data examples validate our theory.

  8. Sequential decoders for large MIMO systems

    KAUST Repository

    Ali, Konpal S.; Abediseid, Walid; Alouini, Mohamed-Slim

    2014-01-01

    the Sequential Decoder using the Fano Algorithm for large MIMO systems. A parameter called the bias is varied to attain different performance-complexity trade-offs. Low values of the bias result in excellent performance but at the expense of high complexity

  9. Automation-aided Task Loads Index based on the Automation Rate Reflecting the Effects on Human Operators in NPPs

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seungmin; Seong, Poonghyun [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Kim, Jonghyun [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2013-05-15

    Many researchers have found that a high automation rate does not guarantee high performance. Therefore, to reflect the effects of automation on human performance, a new estimation method of the automation rate that considers the effects of automation on human operators in nuclear power plants (NPPs) was suggested. These suggested measures express how much automation support human operators but it cannot express the change of human operators' workload, whether the human operators' workload is increased or decreased. Before considering automation rates, whether the adopted automation is good or bad might be estimated in advance. In this study, to estimate the appropriateness of automation according to the change of the human operators' task loads, automation-aided task loads index is suggested based on the concept of the suggested automation rate. To insure plant safety and efficiency on behalf of human operators, various automation systems have been installed in NPPs, and many works which were previously conducted by human operators can now be supported by computer-based operator aids. According to the characteristics of the automation types, the estimation method of the system automation and the cognitive automation rate were suggested. The proposed estimation method concentrates on the effects of introducing automation, so it directly express how much the automated system support human operators. Based on the suggested automation rates, the way to estimate how much the automated system can affect the human operators' cognitive task load is suggested in this study. When there is no automation, the calculated index is 1, and it means there is no change of human operators' task load.

  10. Real-time corrosion monitoring of steel influenced by microbial activity (SRB) under controlled seawater injection conditions

    Energy Technology Data Exchange (ETDEWEB)

    Kane, Russell D. [InterCorr International, Inc., 14503 Bammel N. Houston Road, Suite 300, Houston, TX 77019 (United States); Campbell, Scott [Commercial Microbiology Inc., 10400 Westoffice Drive Suite 107, Houston, TX 77042 (United States)

    2004-07-01

    An experimental study of microbiologically influenced corrosion (MIC) was conducted involving online, real-time monitoring of a bio-film loop under controlled conditions simulating oil field water handling and injection. Bio-film growth, MIC and biocide efficacy were monitored using an automated, multi-technique monitoring system including linear polarization resistance, electrochemical noise and harmonic distortion analysis. This data was correlated with conventional off-line methods to differentiate conditions of varying MIC activity in real-time to facilitate quick assessment and operator intervention. (authors)

  11. Simulation of Jetting in Injection Molding Using a Finite Volume Method

    Directory of Open Access Journals (Sweden)

    Shaozhen Hua

    2016-05-01

    Full Text Available In order to predict the jetting and the subsequent buckling flow more accurately, a three dimensional melt flow model was established on a viscous, incompressible, and non-isothermal fluid, and a control volume-based finite volume method was employed to discretize the governing equations. A two-fold iterative method was proposed to decouple the dependence among pressure, velocity, and temperature so as to reduce the computation and improve the numerical stability. Based on the proposed theoretical model and numerical method, a program code was developed to simulate melt front progress and flow fields. The numerical simulations for different injection speeds, melt temperatures, and gate locations were carried out to explore the jetting mechanism. The results indicate the filling pattern depends on the competition between inertial and viscous forces. When inertial force exceeds the viscous force jetting occurs, then it changes to a buckling flow as the viscous force competes over the inertial force. Once the melt contacts with the mold wall, the melt filling switches to conventional sequential filling mode. Numerical results also indicate jetting length increases with injection speed but changes little with melt temperature. The reasonable agreements between simulated and experimental jetting length and buckling frequency imply the proposed method is valid for jetting simulation.

  12. Comment on: "Cell Therapy for Heart Disease: Trial Sequential Analyses of Two Cochrane Reviews"

    DEFF Research Database (Denmark)

    Castellini, Greta; Nielsen, Emil Eik; Gluud, Christian

    2017-01-01

    Trial Sequential Analysis is a frequentist method to help researchers control the risks of random errors in meta-analyses (1). Fisher and colleagues used Trial Sequential Analysis on cell therapy for heart diseases (2). The present article discusses the usefulness of Trial Sequential Analysis and...

  13. Testosterone Injection

    Science.gov (United States)

    ... typical male characteristics. Testosterone injection works by supplying synthetic testosterone to replace the testosterone that is normally ... as a pellet to be injected under the skin.Testosterone injection may control your symptoms but will ...

  14. Ion channel recordings on an injection-molded polymer chip.

    Science.gov (United States)

    Tanzi, Simone; Matteucci, Marco; Christiansen, Thomas Lehrmann; Friis, Søren; Christensen, Mette Thylstrup; Garnaes, Joergen; Wilson, Sandra; Kutchinsky, Jonatan; Taboryski, Rafael

    2013-12-21

    In this paper, we demonstrate recordings of the ion channel activity across the cell membrane in a biological cell by employing the so-called patch clamping technique on an injection-molded polymer microfluidic device. The findings will allow direct recordings of ion channel activity to be made using the cheapest materials and production platform to date and with the potential for very high throughput. The employment of cornered apertures for cell capture allowed the fabrication of devices without through holes and via a scheme comprising master origination by dry etching in a silicon substrate, electroplating in nickel and injection molding of the final part. The most critical device parameters were identified as the length of the patching capillary and the very low surface roughness on the inside of the capillary. The cross-sectional shape of the orifice was found to be less critical, as both rectangular and semicircular profiles seemed to have almost the same ability to form tight seals with cells with negligible leak currents. The devices were functionally tested using human embryonic kidney cells expressing voltage-gated sodium channels (Nav1.7) and benchmarked against a commercial state-of-the-art system for automated ion channel recordings. These experiments considered current-voltage (IV) relationships for activation and inactivation of the Nav1.7 channels and their sensitivity to a local anesthetic, lidocaine. Both IVs and lidocaine dose-response curves obtained from the injection-molded polymer device were in good agreement with data obtained from the commercial system.

  15. Efficient sequential and parallel algorithms for record linkage.

    Science.gov (United States)

    Mamun, Abdullah-Al; Mi, Tian; Aseltine, Robert; Rajasekaran, Sanguthevar

    2014-01-01

    Integrating data from multiple sources is a crucial and challenging problem. Even though there exist numerous algorithms for record linkage or deduplication, they suffer from either large time needs or restrictions on the number of datasets that they can integrate. In this paper we report efficient sequential and parallel algorithms for record linkage which handle any number of datasets and outperform previous algorithms. Our algorithms employ hierarchical clustering algorithms as the basis. A key idea that we use is radix sorting on certain attributes to eliminate identical records before any further processing. Another novel idea is to form a graph that links similar records and find the connected components. Our sequential and parallel algorithms have been tested on a real dataset of 1,083,878 records and synthetic datasets ranging in size from 50,000 to 9,000,000 records. Our sequential algorithm runs at least two times faster, for any dataset, than the previous best-known algorithm, the two-phase algorithm using faster computation of the edit distance (TPA (FCED)). The speedups obtained by our parallel algorithm are almost linear. For example, we get a speedup of 7.5 with 8 cores (residing in a single node), 14.1 with 16 cores (residing in two nodes), and 26.4 with 32 cores (residing in four nodes). We have compared the performance of our sequential algorithm with TPA (FCED) and found that our algorithm outperforms the previous one. The accuracy is the same as that of this previous best-known algorithm.

  16. Automation of radioimmunoassay

    International Nuclear Information System (INIS)

    Yamaguchi, Chisato; Yamada, Hideo; Iio, Masahiro

    1974-01-01

    Automation systems for measuring Australian antigen by radioimmunoassay under development were discussed. Samples were processed as follows: blood serum being dispensed by automated sampler to the test tube, and then incubated under controlled time and temperature; first counting being omitted; labelled antibody being dispensed to the serum after washing; samples being incubated and then centrifuged; radioactivities in the precipitate being counted by auto-well counter; measurements being tabulated by automated typewriter. Not only well-type counter but also position counter was studied. (Kanao, N.)

  17. Automatic synthesis of sequential control schemes

    International Nuclear Information System (INIS)

    Klein, I.

    1993-01-01

    Of all hard- and software developed for industrial control purposes, the majority is devoted to sequential, or binary valued, control and only a minor part to classical linear control. Typically, the sequential parts of the controller are invoked during startup and shut-down to bring the system into its normal operating region and into some safe standby region, respectively. Despite its importance, fairly little theoretical research has been devoted to this area, and sequential control programs are therefore still created manually without much theoretical support to obtain a systematic approach. We propose a method to create sequential control programs automatically. The main ideas is to spend some effort off-line modelling the plant, and from this model generate the control strategy, that is the plan. The plant is modelled using action structures, thereby concentrating on the actions instead of the states of the plant. In general the planning problem shows exponential complexity in the number of state variables. However, by focusing on the actions, we can identify problem classes as well as algorithms such that the planning complexity is reduced to polynomial complexity. We prove that these algorithms are sound, i.e., the generated solution will solve the stated problem, and complete, i.e., if the algorithms fail, then no solution exists. The algorithms generate a plan as a set of actions and a partial order on this set specifying the execution order. The generated plant is proven to be minimal and maximally parallel. For a larger class of problems we propose a method to split the original problem into a number of simple problems that can each be solved using one of the presented algorithms. It is also shown how a plan can be translated into a GRAFCET chart, and to illustrate these ideas we have implemented a planing tool, i.e., a system that is able to automatically create control schemes. Such a tool can of course also be used on-line if it is fast enough. This

  18. Fault detection in multiply-redundant measurement systems via sequential testing

    International Nuclear Information System (INIS)

    Ray, A.

    1988-01-01

    The theory and application of a sequential test procedure for fault detection and isolation. The test procedure is suited for development of intelligent instrumentation in strategic processes like aircraft and nuclear plants where redundant measurements are usually available for individual critical variables. The test procedure consists of: (1) a generic redundancy management procedure which is essentially independent of the fault detection strategy and measurement noise statistics, and (2) a modified version of sequential probability ratio test algorithm for fault detection and isolation, which functions within the framework of this redundancy management procedure. The sequential test procedure is suitable for real-time applications using commercially available microcomputers and its efficacy has been verified by online fault detection in an operating nuclear reactor. 15 references

  19. 77 FR 48527 - National Customs Automation Program (NCAP) Test Concerning Automated Commercial Environment (ACE...

    Science.gov (United States)

    2012-08-14

    ... National Customs Automation Program (NCAP) test concerning the simplified entry functionality in the... DEPARTMENT OF HOMELAND SECURITY U.S. Customs and Border Protection National Customs Automation Program (NCAP) Test Concerning Automated Commercial Environment (ACE) Simplified Entry: Modification of...

  20. Sequential designs for sensitivity analysis of functional inputs in computer experiments

    International Nuclear Information System (INIS)

    Fruth, J.; Roustant, O.; Kuhnt, S.

    2015-01-01

    Computer experiments are nowadays commonly used to analyze industrial processes aiming at achieving a wanted outcome. Sensitivity analysis plays an important role in exploring the actual impact of adjustable parameters on the response variable. In this work we focus on sensitivity analysis of a scalar-valued output of a time-consuming computer code depending on scalar and functional input parameters. We investigate a sequential methodology, based on piecewise constant functions and sequential bifurcation, which is both economical and fully interpretable. The new approach is applied to a sheet metal forming problem in three sequential steps, resulting in new insights into the behavior of the forming process over time. - Highlights: • Sensitivity analysis method for functional and scalar inputs is presented. • We focus on the discovery of most influential parts of the functional domain. • We investigate economical sequential methodology based on piecewise constant functions. • Normalized sensitivity indices are introduced and investigated theoretically. • Successful application to sheet metal forming on two functional inputs