WorldWideScience

Sample records for automated dose dispensing

  1. Towards more reliable automated multi-dose dispensing: retrospective follow-up study on medication dose errors and product defects.

    Science.gov (United States)

    Palttala, Iida; Heinämäki, Jyrki; Honkanen, Outi; Suominen, Risto; Antikainen, Osmo; Hirvonen, Jouni; Yliruusi, Jouko

    2013-03-01

    To date, little is known on applicability of different types of pharmaceutical dosage forms in an automated high-speed multi-dose dispensing process. The purpose of the present study was to identify and further investigate various process-induced and/or product-related limitations associated with multi-dose dispensing process. The rates of product defects and dose dispensing errors in automated multi-dose dispensing were retrospectively investigated during a 6-months follow-up period. The study was based on the analysis of process data of totally nine automated high-speed multi-dose dispensing systems. Special attention was paid to the dependence of multi-dose dispensing errors/product defects and pharmaceutical tablet properties (such as shape, dimensions, weight, scored lines, coatings, etc.) to profile the most suitable forms of tablets for automated dose dispensing systems. The relationship between the risk of errors in dose dispensing and tablet characteristics were visualized by creating a principal component analysis (PCA) model for the outcome of dispensed tablets. The two most common process-induced failures identified in the multi-dose dispensing are predisposal of tablet defects and unexpected product transitions in the medication cassette (dose dispensing error). The tablet defects are product-dependent failures, while the tablet transitions are dependent on automated multi-dose dispensing systems used. The occurrence of tablet defects is approximately twice as common as tablet transitions. Optimal tablet preparation for the high-speed multi-dose dispensing would be a round-shaped, relatively small/middle-sized, film-coated tablet without any scored line. Commercial tablet products can be profiled and classified based on their suitability to a high-speed multi-dose dispensing process.

  2. Health care professionals’ perspectives on automated multi-dose drug dispensing

    Directory of Open Access Journals (Sweden)

    Bardage C

    2014-12-01

    Full Text Available Background: During the 1980s, manual repackaging of multi-dose medications from pharmacies in Sweden was successively substituted with automated multi-dose drug dispensing (MDD. There are few studies evaluating the consequences of automated MDD with regard to patient safety, and those that investigate this issue are not very extensive. Objectives: To investigate Swedish health care professionals’ perceived experience of automated MDD and its effects on patient adherence and patient safety. Methods: Three questionnaire forms, one for physicians, nurses, and assistant nurses/nursing assistants, were developed based on reviews of the literature and pilot testing of the questions in the intended target groups. The target groups were health professionals prescribing or administrating MDD to patients. A sample (every sixth municipality was drawn from the sampling frame of Swedish municipalities, resulting in 40 municipalities, about 14% of all municipalities in Sweden. Email addresses of general practitioners were obtained from county councils, while the municipalities assisted in getting contact details for nurses, assistant nurses and nursing assistants. A total of 915 questionnaires were distributed electronically to physicians, 515 to nurses, and 4,118 to assistant nurses/nursing assistants. The data were collected in September and October 2012. Results: The response rate among physicians, nurses and assistant nurses/nursing assistants was 31%, 43% and 23%, respectively. The professionals reported that automated MDD reduces duplication of medication, contributes to correct dosages, helps patients take their medication at the right time, and reduces confusion among patients. Fifteen per cent of the physicians and about one-third of the nurses and assistant nurses/nursing assistants reported that generic substitution makes it more difficult for the patient to identify the various medicines available in the sachets. The physicians did, however

  3. Medication Incidents Related to Automated Dose Dispensing in Community Pharmacies and Hospitals - A Reporting System Study

    Science.gov (United States)

    Cheung, Ka-Chun; van den Bemt, Patricia M. L. A.; Bouvy, Marcel L.; Wensing, Michel; De Smet, Peter A. G. M.

    2014-01-01

    Introduction Automated dose dispensing (ADD) is being introduced in several countries and the use of this technology is expected to increase as a growing number of elderly people need to manage their medication at home. ADD aims to improve medication safety and treatment adherence, but it may introduce new safety issues. This descriptive study provides insight into the nature and consequences of medication incidents related to ADD, as reported by healthcare professionals in community pharmacies and hospitals. Methods The medication incidents that were submitted to the Dutch Central Medication incidents Registration (CMR) reporting system were selected and characterized independently by two researchers. Main Outcome Measures Person discovering the incident, phase of the medication process in which the incident occurred, immediate cause of the incident, nature of incident from the healthcare provider's perspective, nature of incident from the patient's perspective, and consequent harm to the patient caused by the incident. Results From January 2012 to February 2013 the CMR received 15,113 incidents: 3,685 (24.4%) incidents from community pharmacies and 11,428 (75.6%) incidents from hospitals. Eventually 1 of 50 reported incidents (268/15,113 = 1.8%) were related to ADD; in community pharmacies more incidents (227/3,685 = 6.2%) were related to ADD than in hospitals (41/11,428 = 0.4%). The immediate cause of an incident was often a change in the patient's medicine regimen or relocation. Most reported incidents occurred in two phases: entering the prescription into the pharmacy information system and filling the ADD bag. Conclusion A proportion of incidents was related to ADD and is reported regularly, especially by community pharmacies. In two phases, entering the prescription into the pharmacy information system and filling the ADD bag, most incidents occurred. A change in the patient's medicine regimen or relocation was the immediate causes of an incident

  4. Dose dispenser for radioactive gas

    International Nuclear Information System (INIS)

    Horwitz, N.H.; Gutkowski, R.E.

    1977-01-01

    An activity metering apparatus for metering predetermined activities of radioactive gas from a supply ampul to dose vials is described. The apparatus includes a shielded ampul housing, a fine metering valve communicating with the ampul housing chamber, a shielded vial housing and a hypodermic needle communicating with the metering valve and received through an opening in the vial housing. A Geiger-Muller tube is adjustably supported opposite an opening in the vial housing, whereby the activity of the radioactive gas dispensed to a partially evacuated vial within the vial chamber may be read directly by a standard laboratory rate meter

  5. Implementation and evaluation of an automated dispensing system.

    Science.gov (United States)

    Schwarz, H O; Brodowy, B A

    1995-04-15

    An institution's experience in replacing a traditional unit dose cassette-exchange system with an automated dispensing system is described. A 24-hour unit dose cassette-exchange system was replaced with an automated dispensing system (Pyxis's Medstation Rx) on a 36-bed cardiovascular surgery unit and an 8-bed cardiovascular intensive care unit. Significantly fewer missing doses were reported after Medstation Rx was implemented. No conclusions could be made about the impact of the system on the reporting of medication errors. The time savings for pharmacy associated with the filling, checking, and delivery of new medication orders equated to about 0.5 full-time equivalent (FTE). Medstation Rx also saved substantial nursing time for acquisition of controlled substances and for controlled-substance inventory taking at shift changes. A financial analysis showed that Medstation Rx could save the institution about $1 million over five years if all personnel time savings could be translated into FTE reductions. The automated system was given high marks by the nurses in a survey; 80% wanted to keep the system on their unit. Pilot implementation of an automated dispensing system improved the efficiency of drug distribution over that of the traditional unit dose cassette-exchange system.

  6. Development of automated blender and dispensing system

    International Nuclear Information System (INIS)

    Kulkarni, Anupama; Aherwal, P.; Patil, C.B.

    2014-01-01

    This paper describes automated blender and dispensing system designed and developed in Nuclear Recycle Board for its reprocessing plant. Obtaining sinterable grade oxide powder from the product solution received in the heavy metal product line involves skilled manpower and time consuming, laborious manual operations. Entire treatment is carried out in a train of closed containments called as glove boxes. In view of this Automated blender and dispensing system has been developed to reduce tedious manual operations. System consists of PLC based control system to drive motorised charging mechanism, a conical ribbon blender which homogenises the product and load cell triggered, indexing dispensing mechanism. Schematic design of the system has been done in-house, while fabrication was outsourced. System has been built, tested and installed at component test facility (CTF) at Tarapur. Actual blending tests were carried out by using dummy material like calcium carbonate and barium carbonate powder, with different sets of parameter. Blended product was chemically analysed for its homogeneity. System has now been put to trial runs by operating staff. This development has circumvented tedious operations of Scooping and increased the throughput. This paper describes challenges in undertaking this developmental work. (author)

  7. Dispensing error rate after implementation of an automated pharmacy carousel system.

    Science.gov (United States)

    Oswald, Scott; Caldwell, Richard

    2007-07-01

    A study was conducted to determine filling and dispensing error rates before and after the implementation of an automated pharmacy carousel system (APCS). The study was conducted in a 613-bed acute and tertiary care university hospital. Before the implementation of the APCS, filling and dispensing rates were recorded during October through November 2004 and January 2005. Postimplementation data were collected during May through June 2006. Errors were recorded in three areas of pharmacy operations: first-dose or missing medication fill, automated dispensing cabinet fill, and interdepartmental request fill. A filling error was defined as an error caught by a pharmacist during the verification step. A dispensing error was defined as an error caught by a pharmacist observer after verification by the pharmacist. Before implementation of the APCS, 422 first-dose or missing medication orders were observed between October 2004 and January 2005. Independent data collected in December 2005, approximately six weeks after the introduction of the APCS, found that filling and error rates had increased. The filling rate for automated dispensing cabinets was associated with the largest decrease in errors. Filling and dispensing error rates had decreased by December 2005. In terms of interdepartmental request fill, no dispensing errors were noted in 123 clinic orders dispensed before the implementation of the APCS. One dispensing error out of 85 clinic orders was identified after implementation of the APCS. The implementation of an APCS at a university hospital decreased medication filling errors related to automated cabinets only and did not affect other filling and dispensing errors.

  8. Impact of an automated dispensing system in outpatient pharmacies.

    Science.gov (United States)

    Humphries, Tammy L; Delate, Thomas; Helling, Dennis K; Richardson, Bruce

    2008-01-01

    To evaluate the impact of an automated dispensing system (ADS) on pharmacy staff work activities and job satisfaction. Cross-sectional, retrospective study. Kaiser Permanente Colorado (KPCO) outpatient pharmacies in September 2005. Pharmacists and technicians from 18 outpatient pharmacies. All KPCO outpatient pharmacists (n = 136) and technicians (n = 160) were surveyed regarding demographics and work activities and pharmacist job satisfaction. Work activities and job satisfaction were compared between pharmacies with and without ADS. Historical prescription purchase records from ADS pharmacies were assessed for pre-ADS to post-ADS changes in productivity. Self-reported pharmacy staff work activities and pharmacist job satisfaction. Pharmacists who responded to the demographic questionnaire (n = 74) were primarily women (60%), had a bachelor's degree in pharmacy (68%), and had been in practice for 10 years or more (53%). Responding technicians (n = 72) were predominantly women (80%) with no postsecondary degree (90%) and fewer than 10 years (68%) in practice. Pharmacists in ADS pharmacies who responded to the work activities questionnaire (n = 50) reported equivalent mean hours spent in patient care activities and filling medication orders compared with non-ADS pharmacists (n = 33; P > 0.05). Similarly, technicians in ADS pharmacies who responded to the work activities questionnaire (n = 64) reported equivalent mean hours spent in filling medication orders compared with non-ADS technicians (n = 38; P > 0.05). An equivalent proportion of ADS pharmacists reported satisfaction with their current job compared with non-ADS pharmacies (P > 0.05). Mean productivity did not increase appreciably after automation (P >0.05). By itself, installing an ADS does not appear to shift pharmacist work activities from dispensing to patient counseling or to increase job satisfaction. Shifting pharmacist work activities from dispensing to counseling and monitoring drug therapy outcomes

  9. The impact of automation on workload and dispensing errors in a hospital pharmacy.

    Science.gov (United States)

    James, K Lynette; Barlow, Dave; Bithell, Anne; Hiom, Sarah; Lord, Sue; Pollard, Mike; Roberts, Dave; Way, Cheryl; Whittlesea, Cate

    2013-04-01

    To determine the effect of installing an original-pack automated dispensing system (ADS) on dispensary workload and prevented dispensing incidents in a hospital pharmacy. Data on dispensary workload and prevented dispensing incidents, defined as dispensing errors detected and reported before medication had left the pharmacy, were collected over 6 weeks at a National Health Service hospital in Wales before and after the installation of an ADS. Workload was measured by non-participant observation using the event recording technique. Prevented dispensing incidents were self-reported by pharmacy staff on standardised forms. Median workloads (measured as items dispensed/person/hour) were compared using Mann-Whitney U tests and rate of prevented dispensing incidents were compared using Chi-square test. Spearman's rank correlation was used to examine the association between workload and prevented dispensing incidents. A P value of ≤0.05 was considered statistically significant. Median dispensary workload was significantly lower pre-automation (9.20 items/person/h) compared to post-automation (13.17 items/person/h, P automation (0.28%) than pre-automation (0.64%, P automation (ρ = 0.23, P automation improves dispensing efficiency and reduces the rate of prevented dispensing incidents. It is proposed that prevented dispensing incidents frequently occurred during periods of high workload due to involuntary automaticity. Prevented dispensing incidents occurring after a busy period were attributed to staff experiencing fatigue after-effects. © 2012 The Authors. IJPP © 2012 Royal Pharmaceutical Society.

  10. Automated drug dispensing system reduces medication errors in an intensive care setting.

    Science.gov (United States)

    Chapuis, Claire; Roustit, Matthieu; Bal, Gaëlle; Schwebel, Carole; Pansu, Pascal; David-Tchouda, Sandra; Foroni, Luc; Calop, Jean; Timsit, Jean-François; Allenet, Benoît; Bosson, Jean-Luc; Bedouch, Pierrick

    2010-12-01

    We aimed to assess the impact of an automated dispensing system on the incidence of medication errors related to picking, preparation, and administration of drugs in a medical intensive care unit. We also evaluated the clinical significance of such errors and user satisfaction. Preintervention and postintervention study involving a control and an intervention medical intensive care unit. Two medical intensive care units in the same department of a 2,000-bed university hospital. Adult medical intensive care patients. After a 2-month observation period, we implemented an automated dispensing system in one of the units (study unit) chosen randomly, with the other unit being the control. The overall error rate was expressed as a percentage of total opportunities for error. The severity of errors was classified according to National Coordinating Council for Medication Error Reporting and Prevention categories by an expert committee. User satisfaction was assessed through self-administered questionnaires completed by nurses. A total of 1,476 medications for 115 patients were observed. After automated dispensing system implementation, we observed a reduced percentage of total opportunities for error in the study compared to the control unit (13.5% and 18.6%, respectively; perror (20.4% and 13.5%; perror showed a significant impact of the automated dispensing system in reducing preparation errors (perrors caused no harm (National Coordinating Council for Medication Error Reporting and Prevention category C). The automated dispensing system did not reduce errors causing harm. Finally, the mean for working conditions improved from 1.0±0.8 to 2.5±0.8 on the four-point Likert scale. The implementation of an automated dispensing system reduced overall medication errors related to picking, preparation, and administration of drugs in the intensive care unit. Furthermore, most nurses favored the new drug dispensation organization.

  11. Multi-dose drug dispensing is a challenge across the primary-secondary care interface

    DEFF Research Database (Denmark)

    Reuther, Lene Orskov; Lysen, Charlotte; Faxholm, Mette

    2011-01-01

    Multi-dose drug dispensing (MDDD) signifies that the patient's medicine is packed in disposable bags corresponding to the dose that should be taken. The purpose of the present study was to investigate how a hospital MDDD instruction was followed.......Multi-dose drug dispensing (MDDD) signifies that the patient's medicine is packed in disposable bags corresponding to the dose that should be taken. The purpose of the present study was to investigate how a hospital MDDD instruction was followed....

  12. Operating experience of an automated TLD dispensing system at CORAL facility

    International Nuclear Information System (INIS)

    Ajoy, K.C.; Dhanasekaran, A.; Arun, R.; Yuvaraj, N.; Karthikeyan, D.; Dheeraj, R.; Akila, R.; Santhanam, R.; Rajagopal, V.; Kumar, Amudhu Ramesh

    2016-01-01

    Monitoring of exposures to occupational workers on individual basis is a regulatory requirement to demonstrate compliance that the dose to the workers is well within the dose limit. Over three decades for monitoring of external exposures, CaSO 4 based Thermo luminescence dosimeters (TLDs), which exhibit the required accuracy, reliability and ruggedness have been employed. TLD cards with unique identification number are loaded in plastic cassettes along with photographs are placed in wooden racks at the entry of the controlled area of the plant. However, there is always a chance that a TLD may be misplaced, used by others or there could be a deliberate act of misuse or abuse. To circumvent this it was decided to install an automated TLD dispensing system with individual TLD tracking as well as locking arrangement. CORAL reprocessing facility at IGCAR was the first to install one such system at Kalpakkam and the operating experience of the system for the last two years is brought out in this paper

  13. [Impact of an automated dispensing system for medical devices in cardiac surgery department].

    Science.gov (United States)

    Clou, E; Dompnier, M; Kably, B; Leplay, C; Poupon, E; Archer, V; Paul, M

    2018-01-01

    To secure medical devices' management, the implementation of automated dispensing system in surgical service has been realized. The objective of this study was to evaluate security, organizational and economic impact of installing automated dispensing system for medical devices (ASDM). The implementation took place in a cardiac surgery department. Security impact was assessed by comparing traceability rate of implantable medical devices one year before and one year after installation. Questionnaire on nurses' perception and satisfaction completed this survey. Resupplying costs, stocks' evolution and investments for the implementation of ASDM were the subject of cost-benefit study. After one year, traceability rate is excellent (100%). Nursing staffs were satisfied with 87.5% by this new system. The introduction of ASDM allowed a qualitative and quantitative decrease in stocks, with a reduction of 30% for purchased medical devices and 15% for implantable medical devices in deposit-consignment. Cost-benefit analysis shows a rapid return on investment. Real stock decrease (purchased medical devices) is equivalent to 46.6% of investment. Implementation of ASDM allows to secure storage and dispensing of medical devices. This system has also an important economic impact and appreciated by users. Copyright © 2017 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  14. Automatic dispensing of liquid nitrogen in submilliliter doses

    Science.gov (United States)

    Milner, C. J.

    1984-10-01

    Well-controlled doses of 0.2 to 0.5 ml of liquid nitrogen are delivered, on electrical signal (not more than once per 5 s), as fills of a miniature bucket raised by an automatic hoist. The bucket is lifted, brimming, from the storage flask and then moved sideways until over the receiver. At this point, a steel ball, which has been resting in and sealing a drain hole in the bucket, is lifted from its seat by a magnet fixed alongside the (now descending) bucket. Design features are outlined: some alternative designs, valving liquid through a short drain tube fixed in the storage flask, are briefly reviewed. In tests the device delivered 74 g (approx. 260 doses) during 63 min, the loss by evaporation meanwhile being 11 g from the bucket, implying a transfer efficiency of 87%. An indirect measure indicated the dose sizes as 354±10 μl approximately.

  15. Population prevalence of high dose paracetamol in dispensed paracetamol/opioid prescription combinations: an observational study

    Science.gov (United States)

    2012-01-01

    Background Paracetamol (acetaminophen) is generally considered a safe medication, but is associated with hepatotoxicity at doses above doses of 4.0 g/day, and even below this daily dose in certain populations. Methods The Nova Scotia Prescription Monitoring Program (NSPMP) in the Canadian province of Nova Scotia is a legislated organization that collects dispensing information on all out-of-hospital prescription controlled drugs dispensed for all Nova Scotia residents. The NSPMP provided data to track all paracetamol/opioids redeemed by adults in Nova Scotia, from July 1, 2005 to June 30, 2010. Trends in the number of adults dispensed these prescriptions and the numbers of prescriptions and tablets dispensed over this period were determined. The numbers and proportions of adults who filled prescriptions exceeding 4.0 g/day and 3.25 g/day were determined for the one-year period July 1, 2009 to June 30, 2010. Data were stratified by sex and age (paracetamol/opioid prescription was lower in each successive one-year period. From July 2009 to June 2010, one in 12 adults (n = 59,197) filled prescriptions for over 13 million paracetamol/opioid tablets. Six percent (n = 3,786) filled prescriptions that exceeded 4.0 g/day and 18.6% (n = 11,008) exceeded 3.25 g/day of paracetamol at least once. These findings exclude non-prescription paracetamol and paracetamol–only prescribed medications. Conclusions A substantial number of individuals who redeem prescriptions for paracetamol/opioid combinations may be at risk of paracetamol-related hepatotoxicity. Healthcare professionals must be vigilant when prescribing and dispensing these medications in order to reduce the associated risks. PMID:22709372

  16. Impact assessment of an automated drug-dispensing system in a tertiary hospital

    Directory of Open Access Journals (Sweden)

    Débora de-Carvalho

    Full Text Available OBJECTIVE: To evaluate the costs and patient safety of a pilot implementation of an automated dispensing cabinet in a critical care unit of a private tertiary hospital in São Paulo/Brazil. METHODS: This study considered pre- (January-August 2013 and post- (October 2013-October 2014 intervention periods. We considered the time and cost of personnel, number of adverse events, audit adjustments to patient bills, and urgent requests and returns of medications to the central pharmacy. Costs were evaluated based on a 5-year analytical horizon and are reported in Brazilian Reals (R$ and US dollars (USD. RESULTS: The observed decrease in the mean number of events reported with regard to the automated drug-dispensing system between pre- and post-implementation periods was not significant. Importantly, the numbers are small, which limits the power of the mean comparative analysis between the two periods. A reduction in work time was observed among the nurses and administrative assistants, whereas pharmacist assistants showed an increased work load that resulted in an overall 6.5 hours of work saved/day and a reduction of R$ 33,598 (USD 14,444 during the first year. The initial investment (R$ 206,065; USD 88,592 would have been paid off in 5 years considering only personnel savings. Other findings included significant reductions of audit adjustments to patient hospital bills and urgent requests and returns of medications to the central pharmacy. CONCLUSIONS: Evidence of the positive impact of this technology on personnel time and costs and on other outcomes of interest is important for decision making by health managers.

  17. Nursing perception of the impact of automated dispensing cabinets on patient safety and ergonomics in a teaching health care center.

    Science.gov (United States)

    Rochais, Elise; Atkinson, Suzanne; Guilbeault, Mélanie; Bussières, Jean-François

    2014-04-01

    To evaluate how nursing staff felt about the impact of automated dispensing cabinets (ADCs) on the safe delivery of health care and workplace ergonomics. To identify the main issues involved in the use of this technology and to describe the corrective measures implemented. Cross-sectional descriptive study with quantitative and qualitative components. A questionnaire that consisted of 33 statements about ADC was distributed from May 24 to June 3, 2011. A total of 172 (46%) of 375 nurses completed the questionnaire. Nursing staff considered the introduction of ADC made their work easier (level of agreement of 90%), helped to safely provide patients with care (91%), and helped to reduce medication incidents/accidents (81%). Nursing staff was particularly satisfied by the narcotic drugs management with the ADCs. Nursing staff were not satisfied with the additional delays in the preparation and administration of a medication dose and the inability to prevent a medication from being administered when stopped on the medication administration record (48%). The nursing staff members were satisfied with the use of ADC and believed it made their work easier, promoted safe patient care, and were perceived to reduce medication incidents/accidents.

  18. [Economic impact of an automated dispensing system in an intensive care unit].

    Science.gov (United States)

    Kheniene, F; Bedouch, P; Durand, M; Marie, F; Brudieu, E; Tourlonnias, M-M; Bongi, P; Allenet, B; Calop, J

    2008-03-01

    Automated dispensing systems (ADS) allow a reduction of medication errors and an improvement of drug distribution in clinical ward. The objective of this study was to evaluate the economic impact of ADS in an intensive care unit. A cost-benefit model was constructed based on the hospital perspective. The system was evaluated before-after implementation of an ADS in a 12-bed cardiovascular intensive care unit of a French teaching hospital: (a) by a measuring nurse and pharmacy technician working time required for various tasks; (b) by measuring the cost of drug storage and the cost of expired drug; (c) by measuring the nurses' acceptability. After ADS was installed, nursing personnel spent less time on medication-related activities (mean of 1.9 hour/day of nursing time). Pharmacy technicians spent more time on floor-stock activities (mean of 0.7 hour/day of technician time). Implementation reduced the cost of drug storage by 56% (14,742 euros) and cost of expired drug by 9,086 euros per year. Finally, cost-benefit analysis including potential savings in terms of working time showed a net benefit of 71,586 euros (14,317 euros/year). The ADS was given high marks by the nurses; 77% wanted to keep it on their unit. Implementation of ADS is expected to generate direct savings for the hospital and working time reallocation, for nurses to interact with patients and for pharmacy technicians to get involved on the ward.

  19. Automated drug dispensing systems in the intensive care unit: a financial analysis.

    Science.gov (United States)

    Chapuis, Claire; Bedouch, Pierrick; Detavernier, Maxime; Durand, Michel; Francony, Gilles; Lavagne, Pierre; Foroni, Luc; Albaladejo, Pierre; Allenet, Benoit; Payen, Jean-Francois

    2015-09-09

    To evaluate the economic impact of automated-drug dispensing systems (ADS) in surgical intensive care units (ICUs). A financial analysis was conducted in three adult ICUs of one university hospital, where ADS were implemented, one in each unit, to replace the traditional floor stock system. Costs were estimated before and after implementation of the ADS on the basis of floor stock inventories, expired drugs, and time spent by nurses and pharmacy technicians on medication-related work activities. A financial analysis was conducted that included operating cash flows, investment cash flows, global cash flow and net present value. After ADS implementation, nurses spent less time on medication-related activities with an average of 14.7 hours saved per day/33 beds. Pharmacy technicians spent more time on floor-stock activities with an average of 3.5 additional hours per day across the three ICUs. The cost of drug storage was reduced by €44,298 and the cost of expired drugs was reduced by €14,772 per year across the three ICUs. Five years after the initial investment, the global cash flow was €148,229 and the net present value of the project was positive by €510,404. The financial modeling of the ADS implementation in three ICUs showed a high return on investment for the hospital. Medication-related costs and nursing time dedicated to medications are reduced with ADS.

  20. Impact of one-dose package dispensing with patient counseling on medication adherence in geriatrics suffering from chronic disorders

    Directory of Open Access Journals (Sweden)

    Narayana Goruntla

    2018-01-01

    Full Text Available Introduction: Medication nonadherence in elderly patients could result in a waste of medical expenses in a long-time span as well as deterioration of the patient's medical condition. Aim: The aim of this study is to evaluate the impact of one-dose package dispensing with patient counseling on medication adherence among elderly patients suffering from chronic disorders. Settings and Design: This is prospective, open-labeled, randomized trial carried out at dispensing pharmacy of the secondary care referral hospital, located in resource-limited settings of Anantapur District, Andhra Pradesh, India. Subjects and Methods: A total of 330 (aged ≥60 years patients were randomly assigned to one of three study groups: Group A (n = 110, no change in dosing and packing; Group B (n = 110, one-dose package dispensing; Group C (n = 110, One-dose package dispensing with patient counseling. Medication adherence levels were measured using a pill count and visual analog scale (VAS method at baseline and follow-up (after 1 month. Statistical Analysis: Descriptive statistics were used to represent the sociodemographic, clinical, and medication adherence profile of study participants. One-way ANOVA test is used to assess significant differences between three groups with a P 60 years who are on multiple medications can benefit from one-dose package dispensing and appropriate counseling. This will improve medication adherence hence better outcomes.

  1. Effects of a direct refill program for automated dispensing cabinets on medication-refill errors.

    Science.gov (United States)

    Helmons, Pieter J; Dalton, Ashley J; Daniels, Charles E

    2012-10-01

    The effects of a direct refill program for automated dispensing cabinets (ADCs) on medication-refill errors were studied. This study was conducted in designated acute care areas of a 386-bed academic medical center. A wholesaler-to-ADC direct refill program, consisting of prepackaged delivery of medications and bar-code-assisted ADC refilling, was implemented in the inpatient pharmacy of the medical center in September 2009. Medication-refill errors in 26 ADCs from the general medicine units, the infant special care unit, the surgical and burn intensive care units, and intermediate units were assessed before and after the implementation of this program. Medication-refill errors were defined as an ADC pocket containing the wrong drug, wrong strength, or wrong dosage form. ADC refill errors decreased by 77%, from 62 errors per 6829 refilled pockets (0.91%) to 8 errors per 3855 refilled pockets (0.21%) (p error type detected before the intervention was the incorrect medication (wrong drug, wrong strength, or wrong dosage form) in the ADC pocket. Of the 54 incorrect medications found before the intervention, 38 (70%) were loaded in a multiple-drug drawer. After the implementation of the new refill process, 3 of the 5 incorrect medications were loaded in a multiple-drug drawer. There were 3 instances of expired medications before and only 1 expired medication after implementation of the program. A redesign of the ADC refill process using a wholesaler-to-ADC direct refill program that included delivery of prepackaged medication and bar-code-assisted refill significantly decreased the occurrence of ADC refill errors.

  2. Advanced Medication Dispenser

    Directory of Open Access Journals (Sweden)

    A.I. Alexan

    2013-12-01

    Full Text Available Medication dispensing is an important activity that can have major implications if done improperly. Dispensing must be done in the correct time interval, at the correct user, with the correct drug and dose. We propose a smart medication dispenser that can satisfy these needs and provide a mechanism for supervision. In order to ensure that the dispensing process is error free, the concept of a new smart medication container is used. A smart medication container is “smart” as it holds the medication dispensing parameters for the drugs it contains: dispensing time and date and name. Based on this information, the actual dispensing is done.

  3. 21 CFR 866.2440 - Automated medium dispensing and stacking device.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2440... stacking device is a device intended for medical purposes to dispense a microbiological culture medium into...

  4. Communicating doses of pediatric liquid medicines to parents/caregivers: a comparison of written dosing directions on prescriptions with labels applied by dispensed pharmacy.

    Science.gov (United States)

    Shah, Rita; Blustein, Leona; Kuffner, Ed; Davis, Lisa

    2014-03-01

    To identify and compare volumetric measures used by healthcare providers in communicating dosing instructions for pediatric liquid prescriptions to parents/caregivers. Dosing instructions were retrospectively reviewed for the 10 most frequently prescribed liquid medications dispensed from 4 community pharmacies for patients aged ≤ 12 years during a 3-month period. Volumetric measures on original prescriptions (ie, milliliters, teaspoons) were compared with those utilized by the pharmacist on the pharmacy label dispensed to the parent/caregiver. Of 649 prescriptions and corresponding pharmacy labels evaluated, 68% of prescriptions and 62% of pharmacy labels communicated dosing in milliliters, 24% of prescriptions and 29% of pharmacy labels communicated dosing in teaspoonfuls, 7% of prescriptions and 0% of pharmacy labels communicated dosing in other measures (ie, milligrams, cubic centimeters, "dose"), and 25% of dispensed pharmacy labels did not reflect units as written in the prescription. Volumetric measures utilized by healthcare professionals in dosing instructions for prescription pediatric oral liquid medications are not consistent. Healthcare professionals and parents/caregivers should be educated on safe dosing practices for liquid pediatric medications. Generalizability to the larger pediatric population may vary depending on pharmacy chain, location, and medications evaluated. Copyright © 2014 Mosby, Inc. All rights reserved.

  5. Implementation and development of an automated, ultra-high-capacity, acoustic, flexible dispensing platform for assay-ready plate delivery.

    Science.gov (United States)

    Griffith, Dylan; Northwood, Roger; Owen, Paul; Simkiss, Ellen; Brierley, Andrew; Cross, Kevin; Slaney, Andrew; Davis, Miranda; Bath, Colin

    2012-10-01

    Compound management faces the daily challenge of providing high-quality samples to drug discovery. The advent of new screening technologies has seen demand for liquid samples move toward nanoliter ranges, dispensed by contactless acoustic droplet ejection. Within AstraZeneca, a totally integrated assay-ready plate production platform has been created to fully exploit the advantages of this technology. This enables compound management to efficiently deliver large throughputs demanded by high-throughput screening while maintaining regular delivery of smaller numbers of compounds in varying plate formats for cellular or biochemical concentration-response curves in support of hit and lead optimization (structure-activity relationship screening). The automation solution, CODA, has the capability to deliver compounds on demand for single- and multiple-concentration ranges, in batch sizes ranging from 1 sample to 2 million samples, integrating seamlessly into local compound and test management systems. The software handles compound orders intelligently, grouping test requests together dependent on output plate type and serial dilution ranges so that source compound vessels are shared among numerous tests, ensuring conservation of sample, reduced labware and costs, and efficiency of work cell logistics. We describe the development of CODA to address the customer demand, challenges experienced, learning made, and subsequent enhancements.

  6. Systems automated reporting of patient dose in digital radiology

    International Nuclear Information System (INIS)

    Collado Chamorro, P.; Sanz Freire, C. J.; Martinez Mirallas, O.; Tejada San Juan, S.; Lopez de Gammarra, M. S.

    2013-01-01

    It has developed a procedure automated reporting of doses to patients in Radiology. This procedure allows to save the time required of the data used to calculate the dose to patients by yields. Also saves the time spent in the transcription of these data for the realization of the necessary calculations. This system has been developed using open source software. The characteristics of the systems of digital radiography for the automation of procedures, in particular the registration of dose should benefit from patient. This procedure is validated and currently in use at our institution. (Author)

  7. Impact of multiple-dose versus single-dose inhaler devices on COPD patients’ persistence with long-acting β2-agonists: a dispensing database analysis

    Science.gov (United States)

    van Boven, Job FM; van Raaij, Joost J; van der Galiën, Ruben; Postma, Maarten J; van der Molen, Thys; Dekhuijzen, PN Richard; Vegter, Stefan

    2014-01-01

    Background: With a growing availability of different devices and types of medication, additional evidence is required to assist clinicians in prescribing the optimal medication in relation to chronic obstructive pulmonary disease (COPD) patients’ persistence with long-acting β2-agonists (LABAs). Aims: To assess the impact of the type of inhaler device (multiple-dose versus single-dose inhalers) on 1-year persistence and switching patterns with LABAs. Methods: A retrospective observational cohort study was performed comparing a cohort of patients initiating multiple-dose inhalers and a cohort initiating single-dose inhalers. The study population consisted of long-acting bronchodilator naive COPD patients, initiating inhalation therapy with mono-LABAs (formoterol, indacaterol or salmeterol). Analyses were performed using pharmacy dispensing data from 1994 to 2012, obtained from the IADB.nl database. Study outcomes were 1-year persistence and switching patterns. Results were adjusted for initial prescriber, initial medication, dosing regimen and relevant comorbidities. Results: In all, 575 patients initiating LABAs were included in the final study cohort. Among them, 475 (83%) initiated a multiple-dose inhaler and 100 (17%) a single-dose inhaler. Further, 269 (47%) initiated formoterol, 9 (2%) indacaterol and 297 (52%) salmeterol. There was no significant difference in persistence between users of multiple-dose or single-dose inhalers (hazard ratio: 0.98, 95% confidence interval: 0.76–1.26, P=0.99). Over 80% re-started or switched medication. Conclusions: There seems no impact of inhaler device (multiple-dose versus single-dose inhalers) on COPD patients’ persistence with LABAs. Over 80% of patients who initially seemed to discontinue LABAs, re-started their initial medication or switched inhalers or medication within 1 year. PMID:25274453

  8. Controlled Substance Reconciliation Accuracy Improvement Using Near Real-Time Drug Transaction Capture from Automated Dispensing Cabinets.

    Science.gov (United States)

    Epstein, Richard H; Dexter, Franklin; Gratch, David M; Perino, Michael; Magrann, Jerry

    2016-06-01

    Accurate accounting of controlled drug transactions by inpatient hospital pharmacies is a requirement in the United States under the Controlled Substances Act. At many hospitals, manual distribution of controlled substances from pharmacies is being replaced by automated dispensing cabinets (ADCs) at the point of care. Despite the promise of improved accountability, a high prevalence (15%) of controlled substance discrepancies between ADC records and anesthesia information management systems (AIMS) has been published, with a similar incidence (15.8%; 95% confidence interval [CI], 15.3% to 16.2%) noted at our institution. Most reconciliation errors are clerical. In this study, we describe a method to capture drug transactions in near real-time from our ADCs, compare them with documentation in our AIMS, and evaluate subsequent improvement in reconciliation accuracy. ADC-controlled substance transactions are transmitted to a hospital interface server, parsed, reformatted, and sent to a software script written in Perl. The script extracts the data and writes them to a SQL Server database. Concurrently, controlled drug totals for each patient having care are documented in the AIMS and compared with the balance of the ADC transactions (i.e., vending, transferring, wasting, and returning drug). Every minute, a reconciliation report is available to anesthesia providers over the hospital Intranet from AIMS workstations. The report lists all patients, the current provider, the balance of ADC transactions, the totals from the AIMS, the difference, and whether the case is still ongoing or had concluded. Accuracy and latency of the ADC transaction capture process were assessed via simulation and by comparison with pharmacy database records, maintained by the vendor on a central server located remotely from the hospital network. For assessment of reconciliation accuracy over time, data were collected from our AIMS from January 2012 to June 2013 (Baseline), July 2013 to April 2014

  9. A flexible-dose dispenser for immediate and extended release 3D printed tablets.

    Science.gov (United States)

    Pietrzak, Katarzyna; Isreb, Abdullah; Alhnan, Mohamed A

    2015-10-01

    The advances in personalised medicine increased the demand for a fast, accurate and reliable production method of tablets that can be digitally controlled by healthcare staff. A flexible dose tablet system is presented in this study that proved to be suitable for immediate and extended release tablets with a realistic drug loading and an easy-to-swallow tablet design. The method bridges the affordable and digitally controlled Fused Deposition Modelling (FDM) 3D printing with a standard pharmaceutical manufacturing process, Hot Melt Extrusion (HME). The reported method was compatible with three methacrylic polymers (Eudragit RL, RS and E) as well as a cellulose-based one (hydroxypropyl cellulose, HPC SSL). The use of a HME based pharmaceutical filament preserved the linear relationship between the mass and printed volume and was utilized to digitally control the dose via an input from computer software with dose accuracy in the range of 91-95%. Higher resolution printing quality doubled the printing time, but showed a little effect on in vitro release pattern of theophylline and weight accuracy. Physical characterization studies indicated that the majority of the model drug (theophylline) in the 3D printed tablet exists in a crystal form. Owing to the small size, ease of use and the highly adjustable nature of FDM 3D printers, the method holds promise for future individualised treatment. Copyright © 2015. Published by Elsevier B.V.

  10. Automated extraction of radiation dose information from CT dose report images.

    Science.gov (United States)

    Li, Xinhua; Zhang, Da; Liu, Bob

    2011-06-01

    The purpose of this article is to describe the development of an automated tool for retrieving texts from CT dose report images. Optical character recognition was adopted to perform text recognitions of CT dose report images. The developed tool is able to automate the process of analyzing multiple CT examinations, including text recognition, parsing, error correction, and exporting data to spreadsheets. The results were precise for total dose-length product (DLP) and were about 95% accurate for CT dose index and DLP of scanned series.

  11. Multi-dose drug dispensing as a tool to improve medication adherence: A study in patients using vitamin K antagonists.

    Science.gov (United States)

    van Rein, Nienke; de Geus, Kristel S; Cannegieter, Suzanne C; Reitsma, Pieter H; van der Meer, Felix J M; Lijfering, Willem M

    2018-01-01

    Multi-dose drug dispensing (MDD) is a dosing aid that provides patients with disposable bags containing all drugs intended for 1 dosing moment. MDD is believed to increase medication adherence, but studies are based on self-reported data, and results may depend on socially desirable answers. Therefore, our purpose was to determine the effect of MDD on medication adherence in non-adherent patients taking vitamin K antagonists (VKAs), and to compare with instructing patients on medication use. We conducted a before-after study in non-adherent patients where MDD was the exposure and change in adherence after MDD initiation was the outcome (within patient comparison). Time in therapeutic range (TTR) was selected as a measure for adherence, as this reflects stability of VKA treatment. To analyze whether MDD improved adherence as compared with standard care (ie, letters or calls from nurses of the anticoagulation clinic), non-adherent patients without MDD were also followed to estimate their TTR change over time (between patient comparison). Eighty-three non-adherent VKA patients started using MDD. The median TTR was 63% before MDD and 73% 6 months after MDD. The within patient TTR increased on average by 13% (95%CI 6% to 21%) within 1 month after starting MDD and remained stable during the next 5 months. The TTR of MDD-patients increased 10% (95%CI 2% to 19%) higher as compared with non-MDD patients within 1 month but was similar after 4 months (TTR difference 3%, 95%CI -2% to 9%). Adherence improved after initiation of MDD. Compared with instructing patients, MDD was associated with better adherence within 1 month but was associated with similar improvement after 4 months. Copyright © 2017 John Wiley & Sons, Ltd.

  12. An automated dose tracking system for adaptive radiation therapy.

    Science.gov (United States)

    Liu, Chang; Kim, Jinkoo; Kumarasiri, Akila; Mayyas, Essa; Brown, Stephen L; Wen, Ning; Siddiqui, Farzan; Chetty, Indrin J

    2018-02-01

    The implementation of adaptive radiation therapy (ART) into routine clinical practice is technically challenging and requires significant resources to perform and validate each process step. The objective of this report is to identify the key components of ART, to illustrate how a specific automated procedure improves efficiency, and to facilitate the routine clinical application of ART. Data was used from patient images, exported from a clinical database and converted to an intermediate format for point-wise dose tracking and accumulation. The process was automated using in-house developed software containing three modularized components: an ART engine, user interactive tools, and integration tools. The ART engine conducts computing tasks using the following modules: data importing, image pre-processing, dose mapping, dose accumulation, and reporting. In addition, custom graphical user interfaces (GUIs) were developed to allow user interaction with select processes such as deformable image registration (DIR). A commercial scripting application programming interface was used to incorporate automated dose calculation for application in routine treatment planning. Each module was considered an independent program, written in C++or C#, running in a distributed Windows environment, scheduled and monitored by integration tools. The automated tracking system was retrospectively evaluated for 20 patients with prostate cancer and 96 patients with head and neck cancer, under institutional review board (IRB) approval. In addition, the system was evaluated prospectively using 4 patients with head and neck cancer. Altogether 780 prostate dose fractions and 2586 head and neck cancer dose fractions went processed, including DIR and dose mapping. On average, daily cumulative dose was computed in 3 h and the manual work was limited to 13 min per case with approximately 10% of cases requiring an additional 10 min for image registration refinement. An efficient and convenient

  13. The NRPB automated thermoluminescent dosemeter and dose record keeping system

    International Nuclear Information System (INIS)

    Dennis, J.A.; Marshall, T.O.; Shaw, K.B.

    1975-03-01

    This report describes the thermoluminescent personal radiation dosemeter and its associated automated processing equipment, which are being developed by the National Radiological Protection Board, together with the operation of a computerised dosemeter issue and record keeping system. The main justifications for introducing these systems are improvements in the organizational efficiency of the maintenance of individual dose records, a more flexible and accurate dosimetry system, and economics in operational costs. The dosemeter is based on a numbered aluminium plate containing two lithium fluoride in polytetrafluorethylene disks for the measurement of surface and body dose. This dosemeter is wrapped in thin plastic and labelled with the wearer's name and address. On return, the dosemeter is checked automatically for radioactive contamination; it is unwrapped and evaluated; the dose readings are included in the wearer's stored dose record; the dosemeter is annealed and is then available for re-issue to another wearer. Dose reports and warnings are automatically issued to the wearer or his employer. (author)

  14. A model for automation of radioactive dose control

    International Nuclear Information System (INIS)

    Ribeiro, Carlos Henrique Calazans; Zambon, Jose Waldir; Bitelli, Ricardo; Honaiser, Eduardo Henrique Rangel

    2009-01-01

    The paper presents a proposal for automation of the personnel dose control system to be used in nuclear medicine environments. The model has considered the Standards and rules of the National Commission of Nuclear Energy (CNEN) and of the Health Ministry. The advantages of the model is a robust management of the integrated dose and technicians qualification status. The software platform selected to be used was the Lotus Notes and an analysis of the advantages, disadvantages of the use of this platform is also presented. (author)

  15. A model for automation of radioactive dose control

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Carlos Henrique Calazans; Zambon, Jose Waldir; Bitelli, Ricardo; Honaiser, Eduardo Henrique Rangel [Centro Tecnologico da Marinha em Sao Paulo (CTMSP), Sao Paulo, SP (Brazil)], e-mail: calazans@ctmsp.mar.mil.br, e-mail: zambon@ctmsp.mar.mil.br, e-mail: bitelli@ctmsp.mar.mil.br, e-mail: honaiser@ctmsp.mar.mil.br

    2009-07-01

    The paper presents a proposal for automation of the personnel dose control system to be used in nuclear medicine environments. The model has considered the Standards and rules of the National Commission of Nuclear Energy (CNEN) and of the Health Ministry. The advantages of the model is a robust management of the integrated dose and technicians qualification status. The software platform selected to be used was the Lotus Notes and an analysis of the advantages, disadvantages of the use of this platform is also presented. (author)

  16. Fully automated treatment planning for head and neck radiotherapy using a voxel-based dose prediction and dose mimicking method

    Science.gov (United States)

    McIntosh, Chris; Welch, Mattea; McNiven, Andrea; Jaffray, David A.; Purdie, Thomas G.

    2017-08-01

    Recent works in automated radiotherapy treatment planning have used machine learning based on historical treatment plans to infer the spatial dose distribution for a novel patient directly from the planning image. We present a probabilistic, atlas-based approach which predicts the dose for novel patients using a set of automatically selected most similar patients (atlases). The output is a spatial dose objective, which specifies the desired dose-per-voxel, and therefore replaces the need to specify and tune dose-volume objectives. Voxel-based dose mimicking optimization then converts the predicted dose distribution to a complete treatment plan with dose calculation using a collapsed cone convolution dose engine. In this study, we investigated automated planning for right-sided oropharaynx head and neck patients treated with IMRT and VMAT. We compare four versions of our dose prediction pipeline using a database of 54 training and 12 independent testing patients by evaluating 14 clinical dose evaluation criteria. Our preliminary results are promising and demonstrate that automated methods can generate comparable dose distributions to clinical. Overall, automated plans achieved an average of 0.6% higher dose for target coverage evaluation criteria, and 2.4% lower dose at the organs at risk criteria levels evaluated compared with clinical. There was no statistically significant difference detected in high-dose conformity between automated and clinical plans as measured by the conformation number. Automated plans achieved nine more unique criteria than clinical across the 12 patients tested and automated plans scored a significantly higher dose at the evaluation limit for two high-risk target coverage criteria and a significantly lower dose in one critical organ maximum dose. The novel dose prediction method with dose mimicking can generate complete treatment plans in 12-13 min without user interaction. It is a promising approach for fully automated treatment

  17. Safe pill-dispensing.

    Science.gov (United States)

    Testa, Massimiliano; Pollard, John

    2007-01-01

    Each patient is supplied with a smart-card containing a Radio Frequency IDentification (RFID) chip storing a unique identification code. The patient places the Smart-card on a pill-dispenser unit containing an RFID reader. The RFID chip is read and the code sent to a Base-station via a wireless Bluetooth link. A database containing both patient details and treatment information is queried at the Base-station using the RFID as the search key. The patient's treatment data (i.e., drug names, quantities, time, etc.) are retrieved and sent back to the pill-dispenser unit via Bluetooth. Appropriate quantities of the required medications are automatically dispensed, unless the patient has already taken his/her daily dose. Safe, confidential communication and operation is ensured.

  18. Sample preparation automation for dosing plutonium in urine

    International Nuclear Information System (INIS)

    Jeanmaire, Lucien; Ballada, Jean; Ridelle Berger, Ariane

    1969-06-01

    After having indicated that dosing urinary plutonium by using the Henry technique can be divided into three stages (plutonium concentration by precipitation, passing the solution on an anionic resin column and plutonium elution, and eluate evaporation to obtain a source of which the radioactivity is measured), and recalled that the automation of the second stage has been reported in another document, this document describes the automation of the first stage, i.e. obtaining from urine a residue containing the plutonium, and sufficiently mineralized to be analyzed by means of ion exchanging resins. Two techniques are proposed, leading to slightly different devices. The different operations to be performed are indicated. The different components of the apparatus are described: beakers, hot plate stirrers, reagent circuits, a system for supernatant suction, and a control-command circuit. The operation and use are then described, and results are given

  19. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    International Nuclear Information System (INIS)

    Christianson, Olav; Li Xiang; Frush, Donald; Samei, Ehsan

    2012-01-01

    Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED adj ). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED adj between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED adj that differed by up to 44% from effective dose estimates that were not

  20. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    Energy Technology Data Exchange (ETDEWEB)

    Christianson, Olav; Li Xiang; Frush, Donald; Samei, Ehsan [Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 and Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States) and Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Department of Physics, Duke University, Durham, North Carolina 27710 (United States); and Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States)

    2012-11-15

    Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED{sub adj}). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED{sub adj} between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED{sub adj} that differed by up to 44% from effective dose

  1. Impact of automated dispensing cabinets on medication selection and preparation error rates in an emergency department: a prospective and direct observational before-and-after study.

    Science.gov (United States)

    Fanning, Laura; Jones, Nick; Manias, Elizabeth

    2016-04-01

    The implementation of automated dispensing cabinets (ADCs) in healthcare facilities appears to be increasing, in particular within Australian hospital emergency departments (EDs). While the investment in ADCs is on the increase, no studies have specifically investigated the impacts of ADCs on medication selection and preparation error rates in EDs. Our aim was to assess the impact of ADCs on medication selection and preparation error rates in an ED of a tertiary teaching hospital. Pre intervention and post intervention study involving direct observations of nurses completing medication selection and preparation activities before and after the implementation of ADCs in the original and new emergency departments within a 377-bed tertiary teaching hospital in Australia. Medication selection and preparation error rates were calculated and compared between these two periods. Secondary end points included the impact on medication error type and severity. A total of 2087 medication selection and preparations were observed among 808 patients pre and post intervention. Implementation of ADCs in the new ED resulted in a 64.7% (1.96% versus 0.69%, respectively, P = 0.017) reduction in medication selection and preparation errors. All medication error types were reduced in the post intervention study period. There was an insignificant impact on medication error severity as all errors detected were categorised as minor. The implementation of ADCs could reduce medication selection and preparation errors and improve medication safety in an ED setting. © 2015 John Wiley & Sons, Ltd.

  2. Fully automated gynecomastia quantification from low-dose chest CT

    Science.gov (United States)

    Liu, Shuang; Sonnenblick, Emily B.; Azour, Lea; Yankelevitz, David F.; Henschke, Claudia I.; Reeves, Anthony P.

    2018-02-01

    Gynecomastia is characterized by the enlargement of male breasts, which is a common and sometimes distressing condition found in over half of adult men over the age of 44. Although the majority of gynecomastia is physiologic or idiopathic, its occurrence may also associate with an extensive variety of underlying systemic disease or drug toxicity. With the recent large-scale implementation of annual lung cancer screening using low-dose chest CT (LDCT), gynecomastia is believed to be a frequent incidental finding on LDCT. A fully automated system for gynecomastia quantification from LDCT is presented in this paper. The whole breast region is first segmented using an anatomyorientated approach based on the propagation of pectoral muscle fronts in the vertical direction. The subareolar region is then localized, and the fibroglandular tissue within it is measured for the assessment of gynecomastia. The presented system was validated using 454 breast regions from non-contrast LDCT scans of 227 adult men. The ground truth was established by an experienced radiologist by classifying each breast into one of the five categorical scores. The automated measurements have been demonstrated to achieve promising performance for the gynecomastia diagnosis with the AUC of 0.86 for the ROC curve and have statistically significant Spearman correlation r=0.70 (p early detection as well as the treatment of both gynecomastia and the underlying medical problems, if any, that cause gynecomastia.

  3. A compact 133Xe gas dispenser

    International Nuclear Information System (INIS)

    Hawkins, T.; Harris, R.

    1977-01-01

    A dispenser for 133 Xe gas is described which is compact and simple to use, allowing the xenon to be dispensed from it shipping ampoule to suitable multi-dose injection vials in a controlled manner and with a high degree of operator safety. The apparatus has no joints and only a single rubber teat, minimizing the risks of adsorption and leakage. A scaled drawing of the dispenser is shown. (U.K.)

  4. PS-022 Complex automated medication systems reduce medication administration error rates in an acute medical ward

    DEFF Research Database (Denmark)

    Risør, Bettina Wulff; Lisby, Marianne; Sørensen, Jan

    2017-01-01

    Background Medication errors have received extensive attention in recent decades and are of significant concern to healthcare organisations globally. Medication errors occur frequently, and adverse events associated with medications are one of the largest causes of harm to hospitalised patients...... cabinet, automated dispensing and barcode medication administration; (2) non-patient specific automated dispensing and barcode medication administration. The occurrence of administration errors was observed in three 3 week periods. The error rates were calculated by dividing the number of doses with one...

  5. Perceptions of Dispensers Regarding Dispensing Practices in ...

    African Journals Online (AJOL)

    Methods: A qualitative study with snowball sampling technique was used to identify fifteen dispensers working in community pharmacies in Islamabad, Peshawar and Lahore. Semi-structured interviews were conducted with the dispensers until the point of saturation was obtained. The interviews which focused on three ...

  6. Labelling of equipment dispensers.

    Science.gov (United States)

    Gray, D C

    1993-01-01

    A new labelling system for use on medical equipment dispensers is tested. This system uses one of the objects stored in each unit of the dispenser as the 'label', by attaching it to the front of the dispenser with tape. The new system was compared to conventional written labelling by timing subjects asked to select items from two dispensers. The new system was 27% quicker than the conventional system. Images Fig. 1 PMID:8110335

  7. The impact of an automated dose-dispensing scheme on user compliance, medication understanding, and medication stockpiles

    DEFF Research Database (Denmark)

    Larsen, Anna Bira; Haugbølle, Lotte Stig

    2007-01-01

    the assumed user benefits. Neither Danish nor international studies dealt with users' perspective on ADD in general or with respect to the pinpointed benefits, and thus exploration was needed. OBJECTIVES: The objective of this article is to respond to the following research question: How does ADD affect users......' handling and consumption of medication in terms of compliance behavior, and how does the assumption of user benefits made by health professionals and legislators measure up to users' experiences with ADD? METHODS: The results built on a secondary analysis of 9 qualitative interviews with a varied selection...... understanding, nor does it automatically eliminate stockpiles of old medication in users' homes. The gap between the perspectives of users and health professionals makes a compelling case for considering users' voices in the development and implementation of future health technologies....

  8. Perceptions of Dispensers Regarding Dispensing Practices in ...

    African Journals Online (AJOL)

    Methods: A qualitative study with snowball sampling technique was used to ... Semi-structured interviews were conducted with the dispensers until the ... and suggestions for improvements were audio-taped, transcribed verbatim and analyzed.

  9. Perceptions of Dispensers Regarding Dispensing Practices in ...

    African Journals Online (AJOL)

    Erah

    1School of Pharmaceutical Sciences, University Sains Malaysia, 11800 Penang, Malaysia, 2Department of Social ... working in community pharmacies in Islamabad, Peshawar and Lahore. ..... situation regarding dispensing practices in the.

  10. Automated dose estimation for lost or damaged dosimeters

    International Nuclear Information System (INIS)

    Thompson, W.L.; Deininger, R.J.

    1988-01-01

    This paper reports that some dosimetry vendors will compute doses for their customers' lost/damaged dosimeters based upon an average of recent dosimeter readings. However, the vendors usually require authorization from the customer for each such occurrence. Therefore, the tedious task of keeping track of the overdue status of each missing dosimeter and constantly notifying the vendor is still present. Also, depending on the monthly variability of a given person's doses, it may be more valid to use the employee's average dose, his/her highest dose over a recent period, an average dose of other employees with similar job duties for that period, or the maximum permissible dose. Thus, the task of estimating doses for lost/damaged dosimeters cannot be delegated to dosimetry vendor. Instead, the radiation safety department must sue the data supplied by the vendor as input for performing estimates. The process is performed automatically at the Medical Center Hospital of Vermont using a personal computer and a relational database

  11. Extraction of CT dose information from DICOM metadata: automated Matlab-based approach.

    Science.gov (United States)

    Dave, Jaydev K; Gingold, Eric L

    2013-01-01

    The purpose of this study was to extract exposure parameters and dose-relevant indexes of CT examinations from information embedded in DICOM metadata. DICOM dose report files were identified and retrieved from a PACS. An automated software program was used to extract from these files information from the structured elements in the DICOM metadata relevant to exposure. Extracting information from DICOM metadata eliminated potential errors inherent in techniques based on optical character recognition, yielding 100% accuracy.

  12. Automation of complex assays: pharmacogenetics of warfarin dosing.

    Science.gov (United States)

    Wu, Whei-Kuo; Hujsak, Paul G; Kureshy, Fareed

    2007-10-01

    AutoGenomics, Inc. (Carlsbad, CA, USA) have developed a multiplex microarray assay for genotyping both VKORC1 and CYP2C9 using the INFINITI(™) Analyzer. Multiple alleles in each DNA sample are analyzed by polymerase chain reaction amplification, followed by detection primer extension using the INFINITI Analyzer. The INFINITI Analyzer performs single-nucleotide polymorphism (SNP) analysis using universal oligonucleotides immobilized on the biochip. To genotype broader ethnic groups, genomic DNA from whole blood was tested for nine SNPs for VKORC1 and six for CYP2C9 genotypes. Information related to all 15 SNPs is needed to determine dosing of population of diverse ethnic origin. The INFINITI system provides genotyping information for same day dosing of warfarin.

  13. Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation.

    Science.gov (United States)

    Shirley, Ben; Li, Yanxin; Knoll, Joan H M; Rogan, Peter K

    2017-09-04

    Biological radiation dose can be estimated from dicentric chromosome frequencies in metaphase cells. Performing these cytogenetic dicentric chromosome assays is traditionally a manual, labor-intensive process not well suited to handle the volume of samples which may require examination in the wake of a mass casualty event. Automated Dicentric Chromosome Identifier and Dose Estimator (ADCI) software automates this process by examining sets of metaphase images using machine learning-based image processing techniques. The software selects appropriate images for analysis by removing unsuitable images, classifies each object as either a centromere-containing chromosome or non-chromosome, further distinguishes chromosomes as monocentric chromosomes (MCs) or dicentric chromosomes (DCs), determines DC frequency within a sample, and estimates biological radiation dose by comparing sample DC frequency with calibration curves computed using calibration samples. This protocol describes the usage of ADCI software. Typically, both calibration (known dose) and test (unknown dose) sets of metaphase images are imported to perform accurate dose estimation. Optimal images for analysis can be found automatically using preset image filters or can also be filtered through manual inspection. The software processes images within each sample and DC frequencies are computed at different levels of stringency for calling DCs, using a machine learning approach. Linear-quadratic calibration curves are generated based on DC frequencies in calibration samples exposed to known physical doses. Doses of test samples exposed to uncertain radiation levels are estimated from their DC frequencies using these calibration curves. Reports can be generated upon request and provide summary of results of one or more samples, of one or more calibration curves, or of dose estimation.

  14. Automation of PCXMC and ImPACT for NASA Astronaut Medical Imaging Dose and Risk Tracking

    Science.gov (United States)

    Bahadori, Amir; Picco, Charles; Flores-McLaughlin, John; Shavers, Mark; Semones, Edward

    2011-01-01

    To automate astronaut organ and effective dose calculations from occupational X-ray and computed tomography (CT) examinations incorporating PCXMC and ImPACT tools and to estimate the associated lifetime cancer risk per the National Council on Radiation Protection & Measurements (NCRP) using MATLAB(R). Methods: NASA follows guidance from the NCRP on its operational radiation safety program for astronauts. NCRP Report 142 recommends that astronauts be informed of the cancer risks from reported exposures to ionizing radiation from medical imaging. MATLAB(R) code was written to retrieve exam parameters for medical imaging procedures from a NASA database, calculate associated dose and risk, and return results to the database, using the Microsoft .NET Framework. This code interfaces with the PCXMC executable and emulates the ImPACT Excel spreadsheet to calculate organ doses from X-rays and CTs, respectively, eliminating the need to utilize the PCXMC graphical user interface (except for a few special cases) and the ImPACT spreadsheet. Results: Using MATLAB(R) code to interface with PCXMC and replicate ImPACT dose calculation allowed for rapid evaluation of multiple medical imaging exams. The user inputs the exam parameter data into the database and runs the code. Based on the imaging modality and input parameters, the organ doses are calculated. Output files are created for record, and organ doses, effective dose, and cancer risks associated with each exam are written to the database. Annual and post-flight exposure reports, which are used by the flight surgeon to brief the astronaut, are generated from the database. Conclusions: Automating PCXMC and ImPACT for evaluation of NASA astronaut medical imaging radiation procedures allowed for a traceable and rapid method for tracking projected cancer risks associated with over 12,000 exposures. This code will be used to evaluate future medical radiation exposures, and can easily be modified to accommodate changes to the risk

  15. Errors detected in pediatric oral liquid medication doses prepared in an automated workflow management system.

    Science.gov (United States)

    Bledsoe, Sarah; Van Buskirk, Alex; Falconer, R James; Hollon, Andrew; Hoebing, Wendy; Jokic, Sladan

    2018-02-01

    The effectiveness of barcode-assisted medication preparation (BCMP) technology on detecting oral liquid dose preparation errors. From June 1, 2013, through May 31, 2014, a total of 178,344 oral doses were processed at Children's Mercy, a 301-bed pediatric hospital, through an automated workflow management system. Doses containing errors detected by the system's barcode scanning system or classified as rejected by the pharmacist were further reviewed. Errors intercepted by the barcode-scanning system were classified as (1) expired product, (2) incorrect drug, (3) incorrect concentration, and (4) technological error. Pharmacist-rejected doses were categorized into 6 categories based on the root cause of the preparation error: (1) expired product, (2) incorrect concentration, (3) incorrect drug, (4) incorrect volume, (5) preparation error, and (6) other. Of the 178,344 doses examined, 3,812 (2.1%) errors were detected by either the barcode-assisted scanning system (1.8%, n = 3,291) or a pharmacist (0.3%, n = 521). The 3,291 errors prevented by the barcode-assisted system were classified most commonly as technological error and incorrect drug, followed by incorrect concentration and expired product. Errors detected by pharmacists were also analyzed. These 521 errors were most often classified as incorrect volume, preparation error, expired product, other, incorrect drug, and incorrect concentration. BCMP technology detected errors in 1.8% of pediatric oral liquid medication doses prepared in an automated workflow management system, with errors being most commonly attributed to technological problems or incorrect drugs. Pharmacists rejected an additional 0.3% of studied doses. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  16. The NRPB's new dosimeter and dose record keeping services

    International Nuclear Information System (INIS)

    Dennis, J.A.; Marshall, T.O.; Shaw, K.B.

    1976-01-01

    A new automated dosimeter and record keeping service which the National Radiological Protection Board (UK) intends to introduce in 1977 is described. The automated system, based on a thermoluminescent dosimeter, will be linked to a fully computerised record keeping system with automatic printing of dose records and Transfer Records operated at its Headquarters at Harwell. The new system will dispense with much manual labour which in the past has introduced inevitable errors and incurred increasing costs. (U.K.)

  17. Analysis of costs to dispense prescriptions in independently owned, closed-door long-term care pharmacies.

    Science.gov (United States)

    Carroll, Norman V; Rupp, Michael T; Holdford, David A

    2014-03-01

    developed to examine the impact of shorter dispensing cycles on LTC pharmacies' CTD. A prescription volume increase of 19% was assumed based on converting only solid oral branded drugs to short-cycle dispensing. A diverse sample of 64 closed-door LTC pharmacies returned usable surveys. Sales from dispensing to LTC facilities accounted for more than 98% of total sales. Respondents indicated that they currently dispensed 23% of total doses in 14-day-or-less cycles and 76% in 28-31 day cycles. Most pharmacies used automated medication packaging technology, heat and cold package sealers, bar code systems, sterile compounding hoods, LTC printers or labelers, and electronic prescribing. The median CTD was $13.54 with an interquartile range (25th to 75th percentiles) of $10.51 to $17.66. More than half of dispensing-related costs were from personnel expense, of which pharmacists and managers accounted for more than 40%. The results of the fixed and variable cost modeling suggested that converting solid oral brand-name drugs from 30-day to 14-day dispensing cycles would lower the median per prescription CTD to between $11.63 and $12.54, depending on the assumptions made about the effects of semivariable costs. However, this decrease in per prescription dispensing cost is dwarfed by an increase in total dispensing cost incurred by pharmacies that results from doubling the monthly volume of short-cycle prescriptions that must be dispensed. The result is that the typical LTC pharmacy in our sample incurred a CTD of $13.54 if the medication is dispensed in a 30-day cycle or $23.26 if the medication is dispensed in two 14-day cycles (at a cost of $11.63 for each cycle dispensed). Our results indicated a median CTD of $13.54 for the typical independently owned, closed-door LTC pharmacy. Moving to a shorter cycle would reduce pharmacies' average per-prescription CTD but would increase the number of prescriptions dispensed per month. Our results indicated that transitioning solid oral

  18. Automating and estimating glomerular filtration rate for dosing medications and staging chronic kidney disease

    Directory of Open Access Journals (Sweden)

    Trinkley KE

    2014-05-01

    Full Text Available Katy E Trinkley,1 S Michelle Nikels,2 Robert L Page II,1 Melanie S Joy11Skaggs School of Pharmacy and Pharmaceutical Sciences, 2School of Medicine, University of Colorado, Aurora, CO, USA Objective: The purpose of this paper is to serve as a review for primary care providers on the bedside methods for estimating glomerular filtration rate (GFR for dosing and chronic kidney disease (CKD staging and to discuss how automated health information technologies (HIT can enhance clinical documentation of staging and reduce medication errors in patients with CKD.Methods: A nonsystematic search of PubMed (through March 2013 was conducted to determine the optimal approach to estimate GFR for dosing and CKD staging and to identify examples of how automated HITs can improve health outcomes in patients with CKD. Papers known to the authors were included, as were scientific statements. Articles were chosen based on the judgment of the authors.Results: Drug-dosing decisions should be based on the method used in the published studies and package labeling that have been determined to be safe, which is most often the Cockcroft–Gault formula unadjusted for body weight. Although Modification of Diet in Renal Disease is more commonly used in practice for staging, the CKD–Epidemiology Collaboration (CKD–EPI equation is the most accurate formula for estimating the CKD staging, especially at higher GFR values. Automated HITs offer a solution to the complexity of determining which equation to use for a given clinical scenario. HITs can educate providers on which formula to use and how to apply the formula in a given clinical situation, ultimately improving appropriate medication and medical management in CKD patients.Conclusion: Appropriate estimation of GFR is key to optimal health outcomes. HITs assist clinicians in both choosing the most appropriate GFR estimation formula and in applying the results of the GFR estimation in practice. Key limitations of the

  19. SU-E-T-139: Automated Daily EPID Exit Dose Analysis Uncovers Treatment Variations

    Energy Technology Data Exchange (ETDEWEB)

    Olch, A [University of Southern California, Los Angeles, CA (United States)

    2015-06-15

    Purpose: To evaluate a fully automated EPID exit dose system for its ability to detect daily treatment deviations including patient setup, delivery, and anatomy changes. Methods: PerFRACTION (Sun Nuclear Corporation) software is a system that uses integrated EPID images taken during patient treatment and automatically pulled from the Aria database and analyzed based on user-defined comparisons. This was used to monitor 20 plans consisting of a total of 859 fields for 18 patients, for a total of 251 fractions. Nine VMAT, 5 IMRT, and 6 3D plans were monitored. The Gamma analysis was performed for each field within a plan, comparing the first fraction against each of the other fractions in each treatment course. A 2% dose difference, 1 mm distance-to-agreement, and 10% dose threshold was used. These tight tolerances were chosen to achieve a high sensitivity to treatment variations. The field passed if 93% of the pixels had a Gamma of 1 or less. Results: Twenty-nine percent of the fields failed. The average plan passing rate was 92.5%.The average 3D plan passing rate was less than for VMAT or IMRT, 84%, vs. an average of 96.2%. When fields failed, an investigation revealed changes in patient anatomy or setup variations, often also leading to variations of transmission through immobilization devices. Conclusion: PerFRACTION is a fully automated system for determining daily changes in dose transmission through the patient that requires no effort other than for the imager panel to be deployed during treatment. A surprising number of fields failed the analysis and can be attributed to important treatment variations that would otherwise not be appreciated. Further study of inter-fraction treatment variations is possible and warranted. Sun Nuclear Corporation provided a license to the software described.

  20. Automated high-dose rate brachytherapy treatment planning for a single-channel vaginal cylinder applicator

    Science.gov (United States)

    Zhou, Yuhong; Klages, Peter; Tan, Jun; Chi, Yujie; Stojadinovic, Strahinja; Yang, Ming; Hrycushko, Brian; Medin, Paul; Pompos, Arnold; Jiang, Steve; Albuquerque, Kevin; Jia, Xun

    2017-06-01

    High dose rate (HDR) brachytherapy treatment planning is conventionally performed manually and/or with aids of preplanned templates. In general, the standard of care would be elevated by conducting an automated process to improve treatment planning efficiency, eliminate human error, and reduce plan quality variations. Thus, our group is developing AutoBrachy, an automated HDR brachytherapy planning suite of modules used to augment a clinical treatment planning system. This paper describes our proof-of-concept module for vaginal cylinder HDR planning that has been fully developed. After a patient CT scan is acquired, the cylinder applicator is automatically segmented using image-processing techniques. The target CTV is generated based on physician-specified treatment depth and length. Locations of the dose calculation point, apex point and vaginal surface point, as well as the central applicator channel coordinates, and the corresponding dwell positions are determined according to their geometric relationship with the applicator and written to a structure file. Dwell times are computed through iterative quadratic optimization techniques. The planning information is then transferred to the treatment planning system through a DICOM-RT interface. The entire process was tested for nine patients. The AutoBrachy cylindrical applicator module was able to generate treatment plans for these cases with clinical grade quality. Computation times varied between 1 and 3 min on an Intel Xeon CPU E3-1226 v3 processor. All geometric components in the automated treatment plans were generated accurately. The applicator channel tip positions agreed with the manually identified positions with submillimeter deviations and the channel orientations between the plans agreed within less than 1 degree. The automatically generated plans obtained clinically acceptable quality.

  1. One-Stop Dispensing

    DEFF Research Database (Denmark)

    Houlind, Morten Baltzer; McNulty, Helle Bach Ølgaard; Treldal, Charlotte

    2018-01-01

    (1) Objective: To assess hospital medication costs and staff time between One-Stop Dispensing (OSD) and the Traditional Medication System (TMS), and to evaluate patient perspectives on OSD. (2) Methods: The study was conducted at Hvidovre Hospital, University of Copenhagen, Denmark in an elective...... gastric surgery and acute orthopedic surgery department. This study consists of three sub-studies including adult patients able to self-manage medication. In Sub-study 1, staff time used to dispense and administer medication in TMS was assessed. Medication cost and OSD staff time were collected in Sub......-study 2, while patient perspectives were assessed in Sub-study 3. Medication costs with two days of discharge medication were compared between measured OSD cost and simulated TMS cost for the same patients. Measured staff time in OSD was compared to simulated staff time in TMS for the same patients...

  2. Automated lung module detection at low-dose CT: preliminary experience

    International Nuclear Information System (INIS)

    Goo, Jin-Mo; Lee, Jeong-Won; Lee, Hyun-Ju; Kim, Seung-Wan; Kim, Jong-Hyo; Im, Jung-Gi

    2003-01-01

    To determine the usefulness of a computer-aided diagnosis (CAD) system for the automated detection of lung nodules at low-dose CT. A CAD system developed for detecting lung nodules was used to process the data provided by 50 consecutive low-dose CT scans. The results of an initial report, a second look review by two chest radiologists, and those obtained by the CAD system were compared, and by reviewing all of these, a gold standard was established. By applying the gold standard, a total of 52 nodules were identified (26 with a diameter ≤ 5 mm; 26 with a diameter > 5 mm). Compared to an initial report, four additional nodules were detected by the CAD system. Three of these, identified only at CAD, formed part of the data used to derive the gold standard. For the detection of nodules > 5 mm in diameter, sensitivity was 77% for the initial report, for the second look review, and 88% for the second look review,and 65% for the CAD system. There were 8.0 ± 5.2 false-positive CAD results per CT study. These preliminary results indicate that a CAD system may improve the detection of pulmonary nodules at low-dose CT

  3. Global real-time dose measurements using the Automated Radiation Measurements for Aerospace Safety (ARMAS) system

    Science.gov (United States)

    Tobiska, W. Kent; Bouwer, D.; Smart, D.; Shea, M.; Bailey, J.; Didkovsky, L.; Judge, K.; Garrett, H.; Atwell, W.; Gersey, B.; Wilkins, R.; Rice, D.; Schunk, R.; Bell, D.; Mertens, C.; Xu, X.; Wiltberger, M.; Wiley, S.; Teets, E.; Jones, B.; Hong, S.; Yoon, K.

    2016-11-01

    The Automated Radiation Measurements for Aerospace Safety (ARMAS) program has successfully deployed a fleet of six instruments measuring the ambient radiation environment at commercial aircraft altitudes. ARMAS transmits real-time data to the ground and provides quality, tissue-relevant ambient dose equivalent rates with 5 min latency for dose rates on 213 flights up to 17.3 km (56,700 ft). We show five cases from different aircraft; the source particles are dominated by galactic cosmic rays but include particle fluxes for minor radiation periods and geomagnetically disturbed conditions. The measurements from 2013 to 2016 do not cover a period of time to quantify galactic cosmic rays' dependence on solar cycle variation and their effect on aviation radiation. However, we report on small radiation "clouds" in specific magnetic latitude regions and note that active geomagnetic, variable space weather conditions may sufficiently modify the magnetospheric magnetic field that can enhance the radiation environment, particularly at high altitudes and middle to high latitudes. When there is no significant space weather, high-latitude flights produce a dose rate analogous to a chest X-ray every 12.5 h, every 25 h for midlatitudes, and every 100 h for equatorial latitudes at typical commercial flight altitudes of 37,000 ft ( 11 km). The dose rate doubles every 2 km altitude increase, suggesting a radiation event management strategy for pilots or air traffic control; i.e., where event-driven radiation regions can be identified, they can be treated like volcanic ash clouds to achieve radiation safety goals with slightly lower flight altitudes or more equatorial flight paths.

  4. Automated detection of lung nodules in low-dose computed tomography

    International Nuclear Information System (INIS)

    Cascio, D.; Cheran, S.C.; Chincarini, A.; De Nunzio, G.; Delogu, P.; Fantacci, M.E.; Gargano, G.; Gori, I.; Retico, A.; Masala, G.L.; Preite Martinez, A.; Santoro, M.; Spinelli, C.; Tarantino, T.

    2007-01-01

    A computer-aided detection (CAD) system for the identification of pulmonary nodules in low-dose multi-detector computed-tomography (CT) images has been developed in the framework of the MAGIC-5 Italian project. One of the main goals of this project is to build a distributed database of lung CT scans in order to enable automated image analysis through a data and cpu GRID infrastructure. The basic modules of our lung-CAD system, consisting in a 3D dot-enhancement filter for nodule detection and a neural classifier for false-positive finding reduction, are described. The system was designed and tested for both internal and sub-pleural nodules. The database used in this study consists of 17 low-dose CT scans reconstructed with thin slice thickness (∝300 slices/scan). The preliminary results are shown in terms of the FROC analysis reporting a good sensitivity (85% range) for both internal and sub-pleural nodules at an acceptable level of false positive findings (1-9 FP/scan); the sensitivity value remains very high (75% range) even at 1-6 FP/scan. (orig.)

  5. TU-H-CAMPUS-JeP3-02: Automated Dose Accumulation and Dose Accuracy Assessment for Online Or Offline Adaptive Replanning

    International Nuclear Information System (INIS)

    Chen, G; Ahunbay, E; Li, X

    2016-01-01

    Purpose: With introduction of high-quality treatment imaging during radiation therapy (RT) delivery, e.g., MR-Linac, adaptive replanning of either online or offline becomes appealing. Dose accumulation of delivered fractions, a prerequisite for the adaptive replanning, can be cumbersome and inaccurate. The purpose of this work is to develop an automated process to accumulate daily doses and to assess the dose accumulation accuracy voxel-by-voxel for adaptive replanning. Methods: The process includes the following main steps: 1) reconstructing daily dose for each delivered fraction with a treatment planning system (Monaco, Elekta) based on the daily images using machine delivery log file and considering patient repositioning if applicable, 2) overlaying the daily dose to the planning image based on deformable image registering (DIR) (ADMIRE, Elekta), 3) assessing voxel dose deformation accuracy based on deformation field using predetermined criteria, and 4) outputting accumulated dose and dose-accuracy volume histograms and parameters. Daily CTs acquired using a CT-on-rails during routine CT-guided RT for sample patients with head and neck and prostate cancers were used to test the process. Results: Daily and accumulated doses (dose-volume histograms, etc) along with their accuracies (dose-accuracy volume histogram) can be robustly generated using the proposed process. The test data for a head and neck cancer case shows that the gross tumor volume decreased by 20% towards the end of treatment course, and the parotid gland mean dose increased by 10%. Such information would trigger adaptive replanning for the subsequent fractions. The voxel-based accuracy in the accumulated dose showed that errors in accumulated dose near rigid structures were small. Conclusion: A procedure as well as necessary tools to automatically accumulate daily dose and assess dose accumulation accuracy is developed and is useful for adaptive replanning. Partially supported by Elekta, Inc.

  6. Using Healthcare Failure Mode and Effect Analysis to reduce medication errors in the process of drug prescription, validation and dispensing in hospitalised patients.

    Science.gov (United States)

    Vélez-Díaz-Pallarés, Manuel; Delgado-Silveira, Eva; Carretero-Accame, María Emilia; Bermejo-Vicedo, Teresa

    2013-01-01

    To identify actions to reduce medication errors in the process of drug prescription, validation and dispensing, and to evaluate the impact of their implementation. A Health Care Failure Mode and Effect Analysis (HFMEA) was supported by a before-and-after medication error study to measure the actual impact on error rate after the implementation of corrective actions in the process of drug prescription, validation and dispensing in wards equipped with computerised physician order entry (CPOE) and unit-dose distribution system (788 beds out of 1080) in a Spanish university hospital. The error study was carried out by two observers who reviewed medication orders on a daily basis to register prescription errors by physicians and validation errors by pharmacists. Drugs dispensed in the unit-dose trolleys were reviewed for dispensing errors. Error rates were expressed as the number of errors for each process divided by the total opportunities for error in that process times 100. A reduction in prescription errors was achieved by providing training for prescribers on CPOE, updating prescription procedures, improving clinical decision support and automating the software connection to the hospital census (relative risk reduction (RRR), 22.0%; 95% CI 12.1% to 31.8%). Validation errors were reduced after optimising time spent in educating pharmacy residents on patient safety, developing standardised validation procedures and improving aspects of the software's database (RRR, 19.4%; 95% CI 2.3% to 36.5%). Two actions reduced dispensing errors: reorganising the process of filling trolleys and drawing up a protocol for drug pharmacy checking before delivery (RRR, 38.5%; 95% CI 14.1% to 62.9%). HFMEA facilitated the identification of actions aimed at reducing medication errors in a healthcare setting, as the implementation of several of these led to a reduction in errors in the process of drug prescription, validation and dispensing.

  7. ASHP national survey of pharmacy practice in hospital settings: dispensing and administration--2011.

    Science.gov (United States)

    Pedersen, Craig A; Schneider, Philip J; Scheckelhoff, Douglas J

    2012-05-01

    Results of the 2011 ASHP national survey of pharmacy practice in hospital settings that pertain to dispensing and administration are presented. A stratified random sample of pharmacy directors at 1401 general and children's medical-surgical hospitals in the United States were surveyed by mail. In this national probability sample survey, the response rate was 40.1%. Decentralization of the medication-use system continues, with 40% of hospitals using a decentralized system and 58% of hospitals planning to use a decentralized model in the future. Automated dispensing cabinets were used by 89% of hospitals, robots were used by 11%, carousels were used in 18%, and machine-readable coding was used in 34% of hospitals to verify doses before dispensing. Overall, 65% of hospitals had a United States Pharmacopeia chapter 797 compliant cleanroom for compounding sterile preparations. Medication administration records (MARs) have become increasingly computerized, with 67% of hospitals using electronic MARs. Bar-code-assisted medication administration was used in 50% of hospitals, and 68% of hospitals had smart infusion pumps. Health information is becoming more electronic, with 67% of hospitals having partially or completely implemented an electronic health record and 34% of hospitals having computerized prescriber order entry. The use of these technologies has substantially increased over the past year. The average number of full-time equivalent staff per 100 occupied beds averaged 17.5 for pharmacists and 15.0 for technicians. Directors of pharmacy reported declining vacancy rates for pharmacists. Pharmacists continue to improve medication use at the dispensing and administration steps of the medication-use system. The adoption of new technology is changing the philosophy of medication distribution, and health information is rapidly becoming electronic.

  8. Recent advances in inkjet dispensing technologies: applications in drug discovery.

    Science.gov (United States)

    Zhu, Xiangcheng; Zheng, Qiang; Yang, Hu; Cai, Jin; Huang, Lei; Duan, Yanwen; Xu, Zhinan; Cen, Peilin

    2012-09-01

    Inkjet dispensing technology is a promising fabrication methodology widely applied in drug discovery. The automated programmable characteristics and high-throughput efficiency makes this approach potentially very useful in miniaturizing the design patterns for assays and drug screening. Various custom-made inkjet dispensing systems as well as specialized bio-ink and substrates have been developed and applied to fulfill the increasing demands of basic drug discovery studies. The incorporation of other modern technologies has further exploited the potential of inkjet dispensing technology in drug discovery and development. This paper reviews and discusses the recent developments and practical applications of inkjet dispensing technology in several areas of drug discovery and development including fundamental assays of cells and proteins, microarrays, biosensors, tissue engineering, basic biological and pharmaceutical studies. Progression in a number of areas of research including biomaterials, inkjet mechanical systems and modern analytical techniques as well as the exploration and accumulation of profound biological knowledge has enabled different inkjet dispensing technologies to be developed and adapted for high-throughput pattern fabrication and miniaturization. This in turn presents a great opportunity to propel inkjet dispensing technology into drug discovery.

  9. Fully automated bone mineral density assessment from low-dose chest CT

    Science.gov (United States)

    Liu, Shuang; Gonzalez, Jessica; Zulueta, Javier; de-Torres, Juan P.; Yankelevitz, David F.; Henschke, Claudia I.; Reeves, Anthony P.

    2018-02-01

    A fully automated system is presented for bone mineral density (BMD) assessment from low-dose chest CT (LDCT). BMD assessment is central in the diagnosis and follow-up therapy monitoring of osteoporosis, which is characterized by low bone density and is estimated to affect 12.3 million US population aged 50 years or older, creating tremendous social and economic burdens. BMD assessment from DXA scans (BMDDXA) is currently the most widely used and gold standard technique for the diagnosis of osteoporosis and bone fracture risk estimation. With the recent large-scale implementation of annual lung cancer screening using LDCT, great potential emerges for the concurrent opportunistic osteoporosis screening. In the presented BMDCT assessment system, each vertebral body is first segmented and labeled with its anatomical name. Various 3D region of interest (ROI) inside the vertebral body are then explored for BMDCT measurements at different vertebral levels. The system was validated using 76 pairs of DXA and LDCT scans of the same subject. Average BMDDXA of L1-L4 was used as the reference standard. Statistically significant (p-value correlation is obtained between BMDDXA and BMDCT at all vertebral levels (T1 - L2). A Pearson correlation of 0.857 was achieved between BMDDXA and average BMDCT of T9-T11 by using a 3D ROI taking into account of both trabecular and cortical bone tissue. These encouraging results demonstrate the feasibility of fully automated quantitative BMD assessment and the potential of opportunistic osteoporosis screening with concurrent lung cancer screening using LDCT.

  10. E85 Dispenser Study

    Energy Technology Data Exchange (ETDEWEB)

    Moriarty, K.; Johnson, C.; Sears, T.; Bergeron, P.

    2009-12-01

    This study reviews E85 dispensing infrastructure advances and issues and evaluates the geographic concentration of flexible fuel vehicles (FFVs), E85 stations, ethanol production facilities, and E85 suppliers. Costs, space, financial incentives, and barriers to adding E85 fueling equipment at existing stations are also assessed. This study found that E85 is increasingly available in the U.S. in half of the states; however, the other half have minimal or no E85 fueling options. Despite these gains, E85 is only available at 1% of U.S. gasoline stations. Ethanol production reached 9.5 billion gallons in 2008, but less than 1% is consumed as E85. FFVs have not reached a significant concentration in any county, metropolitan area, or state.

  11. Application of basic pharmacology and dispensing practice of antibiotics in accredited drug-dispensing outlets in Tanzania

    Directory of Open Access Journals (Sweden)

    Minzi OM

    2013-01-01

    , antibiotic sale without prescription and no referral made, for complicated cases, ADDOs performed worse than DLDBs. As many as 30% of DLDBs and 35% of ADDOs dispensed incomplete doses of antibiotics. In both ADDOs and DLDBs, fortified procaine penicillin powder was dispensed as topical application for injuries.Conclusion: There was no statistical difference between ADDOs and DLDBs in the violation of dispensing practice and both ADDOs and DLDBs expressed poor knowledge of the basic pharmacology of antibiotics.Keywords: antibiotic-dispensing practice, duka la dawa baridi, accredited drug-dispensing outlets

  12. An Automated Inpatient Split-dose Bowel Preparation System Improves Colonoscopy Quality and Reduces Repeat Procedures.

    Science.gov (United States)

    Yadlapati, Rena; Johnston, Elyse R; Gluskin, Adam B; Gregory, Dyanna L; Cyrus, Rachel; Werth, Lindsay; Ciolino, Jody D; Grande, David P; Keswani, Rajesh N

    2017-07-19

    Inpatient colonoscopy preparations are often inadequate, compromising patient safety and procedure quality, while resulting in greater hospital costs. The aims of this study were to: (1) design and implement an electronic inpatient split-dose bowel preparation order set; (2) assess the intervention's impact upon preparation adequacy, repeated colonoscopies, hospital days, and costs. We conducted a single center prospective pragmatic quasiexperimental study of hospitalized adults undergoing colonoscopy. The experimental intervention was designed using DMAIC (define, measure, analyze, improve, and control) methodology. Prospective data collected over 12 months were compared with data from a historical preintervention cohort. The primary outcome was bowel preparation quality and secondary outcomes included number of repeated procedures, hospital days, and costs. On the basis of a Delphi method and DMAIC process, we created an electronic inpatient bowel preparation order set inclusive of a split-dose bowel preparation algorithm, automated orders for rescue medications, and nursing bowel preparation checks. The analysis data set included 969 patients, 445 (46%) in the postintervention group. The adequacy of bowel preparation significantly increased following intervention (86% vs. 43%; P<0.01) and proportion of repeated procedures decreased (2.0% vs. 4.6%; P=0.03). Mean hospital days from bowel preparation initiation to discharge decreased from 8.0 to 6.9 days (P=0.02). The intervention resulted in an estimated 1-year cost-savings of $46,076 based on a reduction in excess hospital days associated with repeated and delayed procedures. Our interdisciplinary initiative targeting inpatient colonoscopy preparations significantly improved quality and reduced repeat procedures, and hospital days. Other institutions should consider utilizing this framework to improve inpatient colonoscopy value.

  13. Automation of radioimmunoassay

    International Nuclear Information System (INIS)

    Yamaguchi, Chisato; Yamada, Hideo; Iio, Masahiro

    1974-01-01

    Automation systems for measuring Australian antigen by radioimmunoassay under development were discussed. Samples were processed as follows: blood serum being dispensed by automated sampler to the test tube, and then incubated under controlled time and temperature; first counting being omitted; labelled antibody being dispensed to the serum after washing; samples being incubated and then centrifuged; radioactivities in the precipitate being counted by auto-well counter; measurements being tabulated by automated typewriter. Not only well-type counter but also position counter was studied. (Kanao, N.)

  14. ASHP national survey of pharmacy practice in hospital settings: Dispensing and administration--2014.

    Science.gov (United States)

    Pedersen, Craig A; Schneider, Philip J; Scheckelhoff, Douglas J

    2015-07-01

    The results of the 2014 ASHP national survey of pharmacy practice in hospital settings that pertain to dispensing and administration are described. A stratified random sample of pharmacy directors at 1435 general and children's medical-surgical hospitals in the United States were surveyed by mail. In this national probability sample survey, the response rate was 29.7%. Ninety-seven percent of hospitals used automated dispensing cabinets in their medication distribution systems, 65.7% of which used individually secured lidded pockets as the predominant configuration. Overall, 44.8% of hospitals used some form of machine-readable coding to verify doses before dispensing in the pharmacy. Overall, 65% of hospital pharmacy departments reported having a cleanroom compliant with United States Pharmacopeia chapter 797. Pharmacists reviewed and approved all medication orders before the first dose was administered, either onsite or by remote order view, except in procedure areas and emergency situations, in 81.2% of hospitals. Adoption rates of electronic health information have rapidly increased, with the widespread use of electronic health records, computer prescriber order entry, barcodes, and smart pumps. Overall, 31.4% of hospitals had pharmacists practicing in ambulatory or primary care clinics. Transitions-of-care services offered by the pharmacy department have generally increased since 2012. Discharge prescription services increased from 11.8% of hospitals in 2012 to 21.5% in 2014. Approximately 15% of hospitals outsourced pharmacy management operations to a contract pharmacy services provider, an increase from 8% in 2011. Health-system pharmacists continue to have a positive impact on improving healthcare through programs that improve the efficiency, safety, and clinical outcomes of medication use in health systems. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  15. Cell dispensing in low-volume range with the immediate drop-on-demand technology (I-DOT).

    Science.gov (United States)

    Schober, Lena; Büttner, Evy; Laske, Christopher; Traube, Andrea; Brode, Tobias; Traube, Andreas Florian; Bauernhansl, Thomas

    2015-04-01

    Handling and dosing of cells comprise the most critical step in the microfabrication of cell-based assay systems for screening and toxicity testing. Therefore, the immediate drop-on-demand technology (I-DOT) was developed to provide a flexible noncontact liquid handling system enabling dispensing of cells and liquid without the risk of cross-contamination down to a precise volume in the nanoliter range. Liquid is dispensed from a source plate within nozzles at the bottom by a short compressed air pulse that is given through a quick release valve into the well, thus exceeding the capillary pressure in the nozzle. Droplets of a defined volume can be spotted directly onto microplates or other cell culture devices. We present a study on the performance and biological impact of this technology by applying the cell line MCF-7, human fibroblasts, and human mesenchymal stem cells (hMSCs). For all cell types tested, viability after dispensing is comparable to the control and exhibits similar proliferation rates in the absence of apoptotic cells, and the differentiation potential of hMSCs is not impaired. The immediate drop-on-demand technology enables accurate cell dosage and offers promising potential for single-cell applications. © 2014 Society for Laboratory Automation and Screening.

  16. Automation systems for radioimmunoassay

    International Nuclear Information System (INIS)

    Yamasaki, Paul

    1974-01-01

    The application of automation systems for radioimmunoassay (RIA) was discussed. Automated systems could be useful in the second step, of the four basic processes in the course of RIA, i.e., preparation of sample for reaction. There were two types of instrumentation, a semi-automatic pipete, and a fully automated pipete station, both providing for fast and accurate dispensing of the reagent or for the diluting of sample with reagent. Illustrations of the instruments were shown. (Mukohata, S.)

  17. SU-E-T-427: Feasibility Study for Evaluation of IMRT Dose Distribution Using Geant4-Based Automated Algorithms

    International Nuclear Information System (INIS)

    Choi, H; Shin, W; Testa, M; Min, C; Kim, J

    2015-01-01

    Purpose: For intensity-modulated radiation therapy (IMRT) treatment planning validation using Monte Carlo (MC) simulations, a precise and automated procedure is necessary to evaluate the patient dose distribution. The aim of this study is to develop an automated algorithm for IMRT simulations using DICOM files and to evaluate the patient dose based on 4D simulation using the Geant4 MC toolkit. Methods: The head of a clinical linac (Varian Clinac 2300 IX) was modeled in Geant4 along with particular components such as the flattening filter and the multi-leaf collimator (MLC). Patient information and the position of the MLC were imported from the DICOM-RT interface. For each position of the MLC, a step- and-shoot technique was adopted. PDDs and lateral profiles were simulated in a water phantom (50×50×40 cm 3 ) and compared to measurement data. We used a lung phantom and MC-dose calculations were compared to the clinical treatment planning used at the Seoul National University Hospital. Results: In order to reproduce the measurement data, we tuned three free parameters: mean and standard deviation of the primary electron beam energy and the beam spot size. These parameters for 6 MV were found to be 5.6 MeV, 0.2378 MeV and 1 mm FWHM respectively. The average dose difference between measurements and simulations was less than 2% for PDDs and radial profiles. The lung phantom study showed fairly good agreement between MC and planning dose despite some unavoidable statistical fluctuation. Conclusion: The current feasibility study using the lung phantom shows the potential for IMRT dose validation using 4D MC simulations using Geant4 tool kits. This research was supported by Korea Institute of Nuclear safety and Development of Measurement Standards for Medical Radiation funded by Korea research Institute of Standards and Science. (KRISS-2015-15011032)

  18. Adaptive Liver Stereotactic Body Radiation Therapy: Automated Daily Plan Reoptimization Prevents Dose Delivery Degradation Caused by Anatomy Deformations

    Energy Technology Data Exchange (ETDEWEB)

    Leinders, Suzanne M. [Erasmus Medical Center-Daniel den Hoed Cancer Center, Rotterdam (Netherlands); Delft University of Technology, Delft (Netherlands); Breedveld, Sebastiaan; Méndez Romero, Alejandra [Erasmus Medical Center-Daniel den Hoed Cancer Center, Rotterdam (Netherlands); Schaart, Dennis [Delft University of Technology, Delft (Netherlands); Seppenwoolde, Yvette, E-mail: y.seppenwoolde@erasmusmc.nl [Erasmus Medical Center-Daniel den Hoed Cancer Center, Rotterdam (Netherlands); Heijmen, Ben J.M. [Erasmus Medical Center-Daniel den Hoed Cancer Center, Rotterdam (Netherlands)

    2013-12-01

    Purpose: To investigate how dose distributions for liver stereotactic body radiation therapy (SBRT) can be improved by using automated, daily plan reoptimization to account for anatomy deformations, compared with setup corrections only. Methods and Materials: For 12 tumors, 3 strategies for dose delivery were simulated. In the first strategy, computed tomography scans made before each treatment fraction were used only for patient repositioning before dose delivery for correction of detected tumor setup errors. In adaptive second and third strategies, in addition to the isocenter shift, intensity modulated radiation therapy beam profiles were reoptimized or both intensity profiles and beam orientations were reoptimized, respectively. All optimizations were performed with a recently published algorithm for automated, multicriteria optimization of both beam profiles and beam angles. Results: In 6 of 12 cases, violations of organs at risk (ie, heart, stomach, kidney) constraints of 1 to 6 Gy in single fractions occurred in cases of tumor repositioning only. By using the adaptive strategies, these could be avoided (<1 Gy). For 1 case, this needed adaptation by slightly underdosing the planning target volume. For 2 cases with restricted tumor dose in the planning phase to avoid organ-at-risk constraint violations, fraction doses could be increased by 1 and 2 Gy because of more favorable anatomy. Daily reoptimization of both beam profiles and beam angles (third strategy) performed slightly better than reoptimization of profiles only, but the latter required only a few minutes of computation time, whereas full reoptimization took several hours. Conclusions: This simulation study demonstrated that replanning based on daily acquired computed tomography scans can improve liver stereotactic body radiation therapy dose delivery.

  19. Exposing exposure: enhancing patient safety through automated data mining of nuclear medicine reports for quality assurance and organ dose monitoring.

    Science.gov (United States)

    Ikuta, Ichiro; Sodickson, Aaron; Wasser, Elliot J; Warden, Graham I; Gerbaudo, Victor H; Khorasani, Ramin

    2012-08-01

    To develop and validate an open-source informatics toolkit capable of creating a radiation exposure data repository from existing nuclear medicine report archives and to demonstrate potential applications of such data for quality assurance and longitudinal patient-specific radiation dose monitoring. This study was institutional review board approved and HIPAA compliant. Informed consent was waived. An open-source toolkit designed to automate the extraction of data on radiopharmaceuticals and administered activities from nuclear medicine reports was developed. After iterative code training, manual validation was performed on 2359 nuclear medicine reports randomly selected from September 17, 1985, to February 28, 2011. Recall (sensitivity) and precision (positive predictive value) were calculated with 95% binomial confidence intervals. From the resultant institutional data repository, examples of usage in quality assurance efforts and patient-specific longitudinal radiation dose monitoring obtained by calculating organ doses from the administered activity and radiopharmaceutical of each examination were provided. Validation statistics yielded a combined recall of 97.6% ± 0.7 (95% confidence interval) and precision of 98.7% ± 0.5. Histograms of administered activity for fluorine 18 fluorodeoxyglucose and iodine 131 sodium iodide were generated. An organ dose heatmap which displays a sample patient's dose accumulation from multiple nuclear medicine examinations was created. Large-scale repositories of radiation exposure data can be extracted from institutional nuclear medicine report archives with high recall and precision. Such repositories enable new approaches in radiation exposure patient safety initiatives and patient-specific radiation dose monitoring.

  20. On demand manufacturing of patient-specific liquid capsules via co-ordinated 3D printing and liquid dispensing.

    Science.gov (United States)

    Okwuosa, Tochukwu C; Soares, Cindy; Gollwitzer, Verena; Habashy, Rober; Timmins, Peter; Alhnan, Mohamed A

    2018-06-15

    A method for the production of liquid capsules with the potential of modifying drug dose and release is presented. For the first time, the co-ordinated use of fused deposition modelling (FDM), 3D printing and liquid dispensing to fabricate individualised dosage form on demand in a fully automated fashion has been demonstrated. Polymethacrylate shells (Eudragit EPO and RL) for immediate and extended release were fabricated using FDM 3D printing and simultaneously filled using a computer-controlled liquid dispenser loaded with model drug solution (theophylline) or suspension (dipyridamole). The impact of printing modes: simultaneous shell printing and filling (single-phase) or sequential 3D printing of shell bottom, filling and shell cap (multi-phase), nozzle size, syringe volume, and shell structure has been reported. The use of shell thickness of 1.6 mm, and concentric architecture allowed successful containment of liquid core whilst maintaining the release properties of the 3D printed liquid capsule. The linear relationship between the theoretical and the actual volumes from the dispenser reflected its potential for accurate dosing (R 2  = 0.9985). Modifying the shell thickness of Eudragit RL capsule allowed a controlled extended drug release without the need for formulation change. Owing to its low cost and versatility, this approach can be adapted to wide spectrum of liquid formulations such as small and large molecule solutions and obviate the need for compatibility with the high temperature of FDM 3D printing process. In a clinical setting, health care staff will be able to instantly manufacture in small volumes liquid capsules with individualised dose contents and release pattern in response to specific patient's needs. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Prescription, dispensation and marketing patterns of methylphenidate

    Directory of Open Access Journals (Sweden)

    Edson Perini

    2014-12-01

    Full Text Available OBJECTIVE To analyze the patterns and legal requirements of methylphenidate consumption. METHODS We conducted a cross-sectional study of the data from prescription notification forms and balance lists of drugs sales – psychoactive and others – subject to special control in the fifth largest city of Brazil, in 2006. We determined the defined and prescribed daily doses, the average prescription and dispensation periods, and the regional sales distribution in the municipality. In addition, we estimated the costs of drug acquisition and analyzed the individual drug consumption profile using the Lorenz curve. RESULTS The balance lists data covered all notified sales of the drug while data from prescription notification forms covered 50.6% of the pharmacies that sold it, including those with the highest sales volumes. Total methylphenidate consumption was 0.37 DDD/1,000 inhabitants/day. Sales were concentrated in more developed areas, and regular-release tablets were the most commonly prescribed pharmaceutical formulation. In some regions of the city, approximately 20.0% of the prescriptions and dispensation exceeded 30 mg/day and 30 days of treatment. CONCLUSIONS Methylphenidate was widely consumed in the municipality and mainly in the most developed areas. Of note, the consumption of formulations with the higher abuse risk was the most predominant. Both its prescription and dispensation contrasted with current pharmacotherapeutic recommendations and legal requirements. Therefore, the commercialization of methylphenidate should be monitored more closely, and its use in the treatment of behavioral changes of psychological disorders needs to be discussed in detail, in line with the concepts of the quality use of medicines.

  2. Systems automated reporting of patient dose in digital radiology; Sistema automatizado para generacion de informes de dosis a paciente en radiologia digital

    Energy Technology Data Exchange (ETDEWEB)

    Collado Chamorro, P.; Sanz Freire, C. J.; Martinez Mirallas, O.; Tejada San Juan, S.; Lopez de Gammarra, M. S.

    2013-07-01

    It has developed a procedure automated reporting of doses to patients in Radiology. This procedure allows to save the time required of the data used to calculate the dose to patients by yields. Also saves the time spent in the transcription of these data for the realization of the necessary calculations. This system has been developed using open source software. The characteristics of the systems of digital radiography for the automation of procedures, in particular the registration of dose should benefit from patient. This procedure is validated and currently in use at our institution. (Author)

  3. Prescribed 3-D Direct Writing of Suspended Micron/Sub-micron Scale Fiber Structures via a Robotic Dispensing System.

    Science.gov (United States)

    Yuan, Hanwen; Cambron, Scott D; Keynton, Robert S

    2015-06-12

    A 3-axis dispensing system is utilized to control the initiating and terminating fiber positions and trajectory via the dispensing software. The polymer fiber length and orientation is defined by the spatial positioning of the dispensing system 3-axis stages. The fiber diameter is defined by the prescribed dispense time of the dispensing system valve, the feed rate (the speed at which the stage traverses from an initiating to a terminating position), the gauge diameter of the dispensing tip, the viscosity and surface tension of the polymer solution, and the programmed drawing length. The stage feed rate affects the polymer solution's evaporation rate and capillary breakup of the filaments. The dispensing system consists of a pneumatic valve controller, a droplet-dispensing valve and a dispensing tip. Characterization of the direct write process to determine the optimum combination of factors leads to repeatedly acquiring the desired range of fiber diameters. The advantage of this robotic dispensing system is the ease of obtaining a precise range of micron/sub-micron fibers onto a desired, programmed location via automated process control. Here, the discussed self-assembled micron/sub-micron scale 3D structures have been employed to fabricate suspended structures to create micron/sub-micron fluidic devices and bioengineered scaffolds.

  4. 21 CFR 888.4200 - Cement dispenser.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cement dispenser. 888.4200 Section 888.4200 Food... DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4200 Cement dispenser. (a) Identification. A cement dispenser is a nonpowered syringe-like device intended for use in placing bone cement (§ 888.3027) into...

  5. A simple low-cost of liquid I-131 dispenser for routine radiopharmaceutical dispensing at nuclear medicine department, Institut Kanser Negara

    Energy Technology Data Exchange (ETDEWEB)

    Said, M. A.; Suhaimi, N. E. F. [Fakulti Sains dan Teknologi, Universiti Kebangsaan Malaysia, 43600 UKM, Bangi Selangor (Malaysia); Ashhar, Z. N., E-mail: aminhpj@gmail.com [Institut Kanser Negara, No 4, Jalan P7, Presint 7, 62250 Putrajaya (Malaysia); Zainon, R. [Advanced Medical & Dental Institute, Universiti Sains Malaysia, Bertam, 13200, Kepala Batas, Pulau Pinang (Malaysia)

    2016-01-22

    In routine radiopharmaceutical Iodine-131 ({sup 131}I) dispensing, the amount of radiation dose received by the personnel depends on the distance between the personnel and the source, the time spent manipulating the source and the amount of shielding used to reduce the dose rate from the source. The novel iRAD-I131 dispenser using recycle {sup 131}I liquid lead pot will lead into low cost production, less maintenance and low dose received by the personnel that prepared the {sup 131}I. The new fabricated of low cost {sup 131}I dispenser was tested and the dose received by personnel were evaluated. The body of lead material is made from 2.5 cm lead shielded coated with epoxy paint to absorb the radiation dose up to 7.4 GBq of {sup 131} I. The lead pot was supported with two stainless steel rod. The Optically Stimulated Luminescence (OSL) nanodot was used in this study to measure the dose rate at both extremities for every personnel who prepared the {sup 131}I. Each OSL nanodot was attached at the fingertip. Three different personnel (experienced between one to ten years above in preparing the radiopharmaceuticals) were participated in this study. The average equivalent dose at right and left hand were 122.694 ± 121.637 µSv/GBq and 77.281 ± 62.146 µSv/GBq respectively. This study found that the dose exposure received using iRAD-I131 was less up to seven times compared to the conventional method. The comparison of experimental data using iRAD-I131 and established radiopharmaceutical dispenser was also discussed. The innovation of {sup 131}I dispenser is highly recommended in a small radiopharmaceutical facility with limited budget. The novel iRAD-I131 enables implementation of higher output liquid dispensing with low radiation dose to the personnel.

  6. Establishment of institutional diagnostic reference level for computed tomography with automated dose-tracking software.

    Science.gov (United States)

    Liang, Chong R; Chen, Priscilla X H; Kapur, Jeevesh; Ong, Michael K L; Quek, Swee T; Kapur, Subhash C

    2017-06-01

    The aim of this study was to establish institutional diagnostic reference levels (DRLs) by summarising doses collected across the five computed tomography (CT) system in our institution. CT dose data of 15940 patients were collected retrospectively from May 2015 to October 2015 in five institutional scanners. The mean, 75th percentile and 90th percentile of the dose spread were calculated according to anatomic region. The common CT examinations such as head, chest, combined abdomen/pelvis (A/P), and combined chest/abdomen/pelvis (C/A/P) were reviewed. Distribution of CT dose index (CTDIvol), dose-length product (DLP) and effective dose (ED) were extracted from the data for single-phasic and multiphasic examinations. The institutional DRL for our CT units were established as mean (50th percentile) of CTDIvol (mGy), DLP (mGy.cm) and ED (mSv) for single and multiphasic studies using the dose-tracking software. In single phasic examination, Head: (49.0 mGy), (978.0 mGy.cm), (2.4 mSv) respectively; Chest: (6.0 mGy), (254.0 mGy.cm), (4.9 mSv) respectively; CT A/P (10.0 mGy), (514.0 mGy.cm), (8.9 mSv) respectively; CT C/A/P (10.0 mGy), (674.0 mGy.cm), (11.8 mSv) respectively. In multiphasic studies: Head (45.0 mGy), (1822.0 mGy.cm), (5.0 mSv) respectively; Chest (8.0 mGy), (577.0 mGy.cm), (10.0 mSv) respectively; CT A/P: (10.0 mGy), (1153.0 mGy.cm), (20.2 mSv) respectively; CT C/A/P: (11.0 mGy), (1090.0 mGy.cm), (19.2 mSv) respectively. The reported metrics offer a variety of information that institutions can use for quality improvement activities. The variations in dose between scanners suggest a large potential for optimisation of radiation dose. © 2017 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology.

  7. Automated estimation of abdominal effective diameter for body size normalization of CT dose.

    Science.gov (United States)

    Cheng, Phillip M

    2013-06-01

    Most CT dose data aggregation methods do not currently adjust dose values for patient size. This work proposes a simple heuristic for reliably computing an effective diameter of a patient from an abdominal CT image. Evaluation of this method on 106 patients scanned on Philips Brilliance 64 and Brilliance Big Bore scanners demonstrates close correspondence between computed and manually measured patient effective diameters, with a mean absolute error of 1.0 cm (error range +2.2 to -0.4 cm). This level of correspondence was also demonstrated for 60 patients on Siemens, General Electric, and Toshiba scanners. A calculated effective diameter in the middle slice of an abdominal CT study was found to be a close approximation of the mean calculated effective diameter for the study, with a mean absolute error of approximately 1.0 cm (error range +3.5 to -2.2 cm). Furthermore, the mean absolute error for an adjusted mean volume computed tomography dose index (CTDIvol) using a mid-study calculated effective diameter, versus a mean per-slice adjusted CTDIvol based on the calculated effective diameter of each slice, was 0.59 mGy (error range 1.64 to -3.12 mGy). These results are used to calculate approximate normalized dose length product values in an abdominal CT dose database of 12,506 studies.

  8. An automated DICOM database capable of arbitrary data mining (including radiation dose indicators) for quality monitoring.

    Science.gov (United States)

    Wang, Shanshan; Pavlicek, William; Roberts, Catherine C; Langer, Steve G; Zhang, Muhong; Hu, Mengqi; Morin, Richard L; Schueler, Beth A; Wellnitz, Clinton V; Wu, Teresa

    2011-04-01

    The U.S. National Press has brought to full public discussion concerns regarding the use of medical radiation, specifically x-ray computed tomography (CT), in diagnosis. A need exists for developing methods whereby assurance is given that all diagnostic medical radiation use is properly prescribed, and all patients' radiation exposure is monitored. The "DICOM Index Tracker©" (DIT) transparently captures desired digital imaging and communications in medicine (DICOM) tags from CT, nuclear imaging equipment, and other DICOM devices across an enterprise. Its initial use is recording, monitoring, and providing automatic alerts to medical professionals of excursions beyond internally determined trigger action levels of radiation. A flexible knowledge base, aware of equipment in use, enables automatic alerts to system administrators of newly identified equipment models or software versions so that DIT can be adapted to the new equipment or software. A dosimetry module accepts mammography breast organ dose, skin air kerma values from XA modalities, exposure indices from computed radiography, etc. upon receipt. The American Association of Physicists in Medicine recommended a methodology for effective dose calculations which are performed with CT units having DICOM structured dose reports. Web interface reporting is provided for accessing the database in real-time. DIT is DICOM-compliant and, thus, is standardized for international comparisons. Automatic alerts currently in use include: email, cell phone text message, and internal pager text messaging. This system extends the utility of DICOM for standardizing the capturing and computing of radiation dose as well as other quality measures.

  9. More than lung cancer: Automated analysis of low-dose screening CT scans

    NARCIS (Netherlands)

    Mets, O.M.

    2012-01-01

    Smoking is a major health care problem and is projected to cause over 8 million deaths per year worldwide in the coming decades. To reduce lung cancer mortality in heavy smokers, several randomized screening trials were initiated in the past years using screening with low-dose Computed Tomography

  10. An automated optimization tool for high-dose-rate (HDR) prostate brachytherapy with divergent needle pattern

    Science.gov (United States)

    Borot de Battisti, M.; Maenhout, M.; de Senneville, B. Denis; Hautvast, G.; Binnekamp, D.; Lagendijk, J. J. W.; van Vulpen, M.; Moerland, M. A.

    2015-10-01

    Focal high-dose-rate (HDR) for prostate cancer has gained increasing interest as an alternative to whole gland therapy as it may contribute to the reduction of treatment related toxicity. For focal treatment, optimal needle guidance and placement is warranted. This can be achieved under MR guidance. However, MR-guided needle placement is currently not possible due to space restrictions in the closed MR bore. To overcome this problem, a MR-compatible, single-divergent needle-implant robotic device is under development at the University Medical Centre, Utrecht: placed between the legs of the patient inside the MR bore, this robot will tap the needle in a divergent pattern from a single rotation point into the tissue. This rotation point is just beneath the perineal skin to have access to the focal prostate tumor lesion. Currently, there is no treatment planning system commercially available which allows optimization of the dose distribution with such needle arrangement. The aim of this work is to develop an automatic inverse dose planning optimization tool for focal HDR prostate brachytherapy with needle insertions in a divergent configuration. A complete optimizer workflow is proposed which includes the determination of (1) the position of the center of rotation, (2) the needle angulations and (3) the dwell times. Unlike most currently used optimizers, no prior selection or adjustment of input parameters such as minimum or maximum dose or weight coefficients for treatment region and organs at risk is required. To test this optimizer, a planning study was performed on ten patients (treatment volumes ranged from 8.5 cm3to 23.3 cm3) by using 2-14 needle insertions. The total computation time of the optimizer workflow was below 20 min and a clinically acceptable plan was reached on average using only four needle insertions.

  11. Near real-time automated dose restoration in IMPT to compensate for daily tissue density variations in prostate cancer

    Science.gov (United States)

    Jagt, Thyrza; Breedveld, Sebastiaan; van de Water, Steven; Heijmen, Ben; Hoogeman, Mischa

    2017-06-01

    Proton therapy is very sensitive to daily density changes along the pencil beam paths. The purpose of this study is to develop and evaluate an automated method for adaptation of IMPT plans to compensate for these daily tissue density variations. A two-step restoration method for ‘densities-of-the-day’ was created: (1) restoration of spot positions (Bragg peaks) by adapting the energy of each pencil beam to the new water equivalent path length; and (2) re-optimization of pencil beam weights by minimizing the dosimetric difference with the planned dose distribution, using a fast and exact quadratic solver. The method was developed and evaluated using 8-10 repeat CT scans of 10 prostate cancer patients. Experiments demonstrated that giving a high weight to the PTV in the re-optimization resulted in clinically acceptable restorations. For all scans we obtained V 95%  ⩾  98% and V 107%  ⩽  2%. For the bladder, the differences between the restored and the intended treatment plan were below  +2 Gy and  +2%-point. The rectum differences were below  +2 Gy and  +2%-point for 90% of the scans. In the remaining scans the rectum was filled with air, which partly overlapped with the PTV. The air cavity distorted the Bragg peak resulting in less favorable rectum doses.

  12. Direct-Dispense Polymeric Waveguides Platform for Optical Chemical Sensors

    Directory of Open Access Journals (Sweden)

    Mohamad Hajj-Hassan

    2008-12-01

    Full Text Available We describe an automated robotic technique called direct-dispense to fabricate a polymeric platform that supports optical sensor arrays. Direct-dispense, which is a type of the emerging direct-write microfabrication techniques, uses fugitive organic inks in combination with cross-linkable polymers to create microfluidic channels and other microstructures. Specifically, we describe an application of direct-dispensing to develop optical biochemical sensors by fabricating planar ridge waveguides that support sol-gelderived xerogel-based thin films. The xerogel-based sensor materials act as host media to house luminophore biochemical recognition elements. As a prototype implementation, we demonstrate gaseous oxygen (O2 responsive optical sensors that operate on the basis of monitoring luminescence intensity signals. The optical sensor employs a Light Emitting Diode (LED excitation source and a standard silicon photodiode as the detector. The sensor operates over the full scale (0%-100% of O2 concentrations with a response time of less than 1 second. This work has implications for the development of miniaturized multisensor platforms that can be cost-effectively and reliably mass-produced.

  13. Development, implementation and outcome analysis of semi-automated alerts for metformin dose adjustment in hospitalized patients with renal impairment.

    Science.gov (United States)

    Niedrig, David; Krattinger, Regina; Jödicke, Annika; Gött, Carmen; Bucklar, Guido; Russmann, Stefan

    2016-10-01

    Overdosing of the oral antidiabetic metformin in impaired renal function is an important contributory cause to life-threatening lactic acidosis. The presented project aimed to quantify and prevent this avoidable medication error in clinical practice. We developed and implemented an algorithm into a hospital's clinical information system that prospectively identifies metformin prescriptions if the estimated glomerular filtration rate is below 60 mL/min. Resulting real-time electronic alerts are sent to clinical pharmacologists and pharmacists, who validate cases in electronic medical records and contact prescribing physicians with recommendations if necessary. The screening algorithm has been used in routine clinical practice for 3 years and generated 2145 automated alerts (about 2 per day). Validated expert recommendations regarding metformin therapy, i.e., dose reduction or stop, were issued for 381 patients (about 3 per week). Follow-up was available for 257 cases, and prescribers' compliance with recommendations was 79%. Furthermore, during 3 years, we identified eight local cases of lactic acidosis associated with metformin therapy in renal impairment that could not be prevented, e.g., because metformin overdosing had occurred before hospitalization. Automated sensitive screening followed by specific expert evaluation and personal recommendations can prevent metformin overdosing in renal impairment with high efficiency and efficacy. Repeated cases of metformin-associated lactic acidosis in renal impairment underline the clinical relevance of this medication error. Our locally developed and customized alert system is a successful proof of concept for a proactive clinical drug safety program that is now expanded to other clinically and economically relevant medication errors. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  14. IoT for Real-Time Measurement of High-Throughput Liquid Dispensing in Laboratory Environments.

    Science.gov (United States)

    Shumate, Justin; Baillargeon, Pierre; Spicer, Timothy P; Scampavia, Louis

    2018-04-01

    Critical to maintaining quality control in high-throughput screening is the need for constant monitoring of liquid-dispensing fidelity. Traditional methods involve operator intervention with gravimetric analysis to monitor the gross accuracy of full plate dispenses, visual verification of contents, or dedicated weigh stations on screening platforms that introduce potential bottlenecks and increase the plate-processing cycle time. We present a unique solution using open-source hardware, software, and 3D printing to automate dispenser accuracy determination by providing real-time dispense weight measurements via a network-connected precision balance. This system uses an Arduino microcontroller to connect a precision balance to a local network. By integrating the precision balance as an Internet of Things (IoT) device, it gains the ability to provide real-time gravimetric summaries of dispensing, generate timely alerts when problems are detected, and capture historical dispensing data for future analysis. All collected data can then be accessed via a web interface for reviewing alerts and dispensing information in real time or remotely for timely intervention of dispense errors. The development of this system also leveraged 3D printing to rapidly prototype sensor brackets, mounting solutions, and component enclosures.

  15. Real time monitoring automation of dose rate absorbed in air due to environmental gamma radiation

    International Nuclear Information System (INIS)

    Dominguez Ley, Orlando; Capote Ferrera, Eduardo; Carrazana Gonzalez, Jorge A.; Manzano de Armas, Jose F.; Alonso Abad, Dolores; Prendes Alonso, Miguel; Tomas Zerquera, Juan; Caveda Ramos, Celia A.; Kalber, Olof; Fabelo Bonet, Orlando; Montalvan Estrada, Adelmo; Cartas Aguila, Hector; Leyva Fernandez, Julio C.

    2005-01-01

    The Center of Radiation Protection and Hygiene (CPHR) as the head institution of the National Radiological Environmental Surveillance Network (RNVRA) has strengthened its detection and response capacity for a radiological emergency situation. The measurements of gamma dose rate at the main point of the RNVRA are obtained in real time and the CPHR receives the data coming from those points in a short time. To achieve the operability of the RNVRA it was necessary to complete the existent monitoring facilities using 4 automatic gamma probes, implementing in this way a real time measurement system. The software, GenitronProbe for obtaining the data automatically from the probe, Data Mail , for sending the data via e-mail, and Gamma Red , for receiving and processing the data in the head institution ,were developed

  16. Automated aortic calcium scoring on low-dose chest computed tomography

    International Nuclear Information System (INIS)

    Isgum, Ivana; Rutten, Annemarieke; Prokop, Mathias; Staring, Marius; Klein, Stefan; Pluim, Josien P. W.; Viergever, Max A.; Ginneken, Bram van

    2010-01-01

    Purpose: Thoracic computed tomography (CT) scans provide information about cardiovascular risk status. These scans are non-ECG synchronized, thus precise quantification of coronary calcifications is difficult. Aortic calcium scoring is less sensitive to cardiac motion, so it is an alternative to coronary calcium scoring as an indicator of cardiovascular risk. The authors developed and evaluated a computer-aided system for automatic detection and quantification of aortic calcifications in low-dose noncontrast-enhanced chest CT. Methods: The system was trained and tested on scans from participants of a lung cancer screening trial. A total of 433 low-dose, non-ECG-synchronized, noncontrast-enhanced 16 detector row examinations of the chest was randomly divided into 340 training and 93 test data sets. A first observer manually identified aortic calcifications on training and test scans. A second observer did the same on the test scans only. First, a multiatlas-based segmentation method was developed to delineate the aorta. Segmented volume was thresholded and potential calcifications (candidate objects) were extracted by three-dimensional connected component labeling. Due to image resolution and noise, in rare cases extracted candidate objects were connected to the spine. They were separated into a part outside and parts inside the aorta, and only the latter was further analyzed. All candidate objects were represented by 63 features describing their size, position, and texture. Subsequently, a two-stage classification with a selection of features and k-nearest neighbor classifiers was performed. Based on the detected aortic calcifications, total calcium volume score was determined for each subject. Results: The computer system correctly detected, on the average, 945 mm 3 out of 965 mm 3 (97.9%) calcified plaque volume in the aorta with an average of 64 mm 3 of false positive volume per scan. Spearman rank correlation coefficient was ρ=0.960 between the system and the

  17. Antimalarial Drugs for Pediatrics - Prescribing and Dispensing ...

    African Journals Online (AJOL)

    Purpose: To assess dispensing and prescribing practices with regard to antimalarial drugs for pediatrics in private pharmacies and public hospitals in Dar es Salaam, Tanzania. Methods: This was a cross-sectional, descriptive study that assessed the knowledge and practice of 200 drug dispensers in the private community ...

  18. Dissolvable microneedle fabrication using piezoelectric dispensing technology.

    Science.gov (United States)

    Allen, Evin A; O'Mahony, Conor; Cronin, Michael; O'Mahony, Thomas; Moore, Anne C; Crean, Abina M

    2016-03-16

    Dissolvable microneedle (DMN) patches are novel dosage forms for the percutaneous delivery of vaccines. DMN are routinely fabricated by dispensing liquid formulations into microneedle-shaped moulds. The liquid formulation within the mould is then dried to create dissolvable vaccine-loaded microneedles. The precision of the dispensing process is critical to the control of formulation volume loaded into each dissolvable microneedle structure. The dispensing process employed must maintain vaccine integrity. Wetting of mould surfaces by the dispensed formulation is also an important consideration for the fabrication of sharp-tipped DMN. Sharp-tipped DMN are essential for ease of percutaneous administration. In this paper, we demonstrate the ability of a piezoelectric dispensing system to dispense picolitre formulation volumes into PDMS moulds enabling the fabrication of bilayer DMN. The influence of formulation components (trehalose and polyvinyl alcohol (PVA) content) and piezoelectric actuation parameters (voltage, frequency and back pressure) on drop formation is described. The biological integrity of a seasonal influenza vaccine following dispensing was investigated and maintained voltage settings of 30 V but undermined at higher settings, 50 and 80 V. The results demonstrate the capability of piezoelectric dispensing technology to precisely fabricate bilayer DMN. They also highlight the importance of identifying formulation and actuation parameters to ensure controlled droplet formulation and vaccine stabilisation. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. SU-F-T-440: The Feasibility Research of Checking Cervical Cancer IMRT Pre- Treatment Dose Verification by Automated Treatment Planning Verification System

    Energy Technology Data Exchange (ETDEWEB)

    Liu, X; Yin, Y; Lin, X [Shandong Cancer Hospital and Institute, China, Jinan, Shandong (China)

    2016-06-15

    Purpose: To assess the preliminary feasibility of automated treatment planning verification system in cervical cancer IMRT pre-treatment dose verification. Methods: The study selected randomly clinical IMRT treatment planning data for twenty patients with cervical cancer, all IMRT plans were divided into 7 fields to meet the dosimetric goals using a commercial treatment planning system(PianncleVersion 9.2and the EclipseVersion 13.5). The plans were exported to the Mobius 3D (M3D)server percentage differences of volume of a region of interest (ROI) and dose calculation of target region and organ at risk were evaluated, in order to validate the accuracy automated treatment planning verification system. Results: The difference of volume for Pinnacle to M3D was less than results for Eclipse to M3D in ROI, the biggest difference was 0.22± 0.69%, 3.5±1.89% for Pinnacle and Eclipse respectively. M3D showed slightly better agreement in dose of target and organ at risk compared with TPS. But after recalculating plans by M3D, dose difference for Pinnacle was less than Eclipse on average, results were within 3%. Conclusion: The method of utilizing the automated treatment planning system to validate the accuracy of plans is convenientbut the scope of differences still need more clinical patient cases to determine. At present, it should be used as a secondary check tool to improve safety in the clinical treatment planning.

  20. Automated calculation of point A coordinates for CT-based high-dose-rate brachytherapy of cervical cancer

    Directory of Open Access Journals (Sweden)

    Hyejoo Kang

    2017-07-01

    Full Text Available Purpose: The goal is to develop a stand-alone application, which automatically and consistently computes the coordinates of the dose calculation point recommended by the American Brachytherapy Society (i.e., point A based solely on the implanted applicator geometry for cervical cancer brachytherapy. Material and methods: The application calculates point A coordinates from the source dwell geometries in the computed tomography (CT scans, and outputs the 3D coordinates in the left and right directions. The algorithm was tested on 34 CT scans of 7 patients treated with high-dose-rate (HDR brachytherapy using tandem and ovoid applicators. A single experienced user retrospectively and manually inserted point A into each CT scan, whose coordinates were used as the “gold standard” for all comparisons. The gold standard was subtracted from the automatically calculated points, a second manual placement by the same experienced user, and the clinically used point coordinates inserted by multiple planners. Coordinate differences and corresponding variances were compared using nonparametric tests. Results: Automatically calculated, manually placed, and clinically used points agree with the gold standard to < 1 mm, 1 mm, 2 mm, respectively. When compared to the gold standard, the average and standard deviation of the 3D coordinate differences were 0.35 ± 0.14 mm from automatically calculated points, 0.38 ± 0.21 mm from the second manual placement, and 0.71 ± 0.44 mm from the clinically used point coordinates. Both the mean and standard deviations of the 3D coordinate differences were statistically significantly different from the gold standard, when point A was placed by multiple users (p < 0.05 but not when placed repeatedly by a single user or when calculated automatically. There were no statistical differences in doses, which agree to within 1-2% on average for all three groups. Conclusions: The study demonstrates that the automated algorithm

  1. Disruptive innovation in community pharmacy - Impact of automation on the pharmacist workforce.

    Science.gov (United States)

    Spinks, Jean; Jackson, John; Kirkpatrick, Carl M; Wheeler, Amanda J

    Pharmacy workforce planning has been relatively static for many decades. However, like all industries, health care is exposed to potentially disruptive technological changes. Automated dispensing systems have been available to pharmacy for over a decade and have been applied to a range of repetitive technical processes which are at risk of error, including record keeping, item selection, labeling and dose packing. To date, most applications of this technology have been at the local level, such as hospital pharmacies or single-site community pharmacies. However, widespread implementation of a more centralized automated dispensing model, such as the 'hub and spoke' model currently being debated in the United Kingdom, could cause a 'technology shock,' delivering industry-wide efficiencies, improving medication accessibility and lowering costs to consumers and funding agencies. Some of pharmacists' historical roles may be made redundant, and new roles may be created, decoupling pharmacists to a certain extent from the dispensing and supply process. It may also create an additional opportunity for pharmacists to be acknowledged and renumerated for professional services that extend beyond the dispensary. Such a change would have significant implications for the organization and funding of community pharmacy services as well as pharmacy workforce planning. This paper discusses the prospect of centralized automated dispensing systems and how this may impact on the pharmacy workforce. It concludes that more work needs to be done in the realm of pharmacy workforce planning to ensure that the introduction of any new technology delivers optimal outcomes to consumers, insurers and the pharmacy workforce. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Cloud-based CT dose monitoring using the DICOM-structured report. Fully automated analysis in regard to national diagnostic reference levels

    International Nuclear Information System (INIS)

    Boos, J.; Rubbert, C.; Heusch, P.; Lanzman, R.S.; Aissa, J.; Antoch, G.; Kroepil, P.

    2016-01-01

    To implement automated CT dose data monitoring using the DICOM-Structured Report (DICOM-SR) in order to monitor dose-related CT data in regard to national diagnostic reference levels (DRLs). Materials and Methods: We used a novel in-house co-developed software tool based on the DICOM-SR to automatically monitor dose-related data from CT examinations. The DICOM-SR for each CT examination performed between 09/2011 and 03/2015 was automatically anonymized and sent from the CT scanners to a cloud server. Data was automatically analyzed in accordance with body region, patient age and corresponding DRL for volumetric computed tomography dose index (CTDI vol ) and dose length product (DLP). Results: Data of 36 523 examinations (131 527 scan series) performed on three different CT scanners and one PET/CT were analyzed. The overall mean CTDI vol and DLP were 51.3 % and 52.8 % of the national DRLs, respectively. CTDI vol and DLP reached 43.8 % and 43.1 % for abdominal CT (n = 10 590), 66.6 % and 69.6 % for cranial CT (n = 16 098) and 37.8 % and 44.0 % for chest CT (n = 10 387) of the compared national DRLs, respectively. Overall, the CTDI vol exceeded national DRLs in 1.9 % of the examinations, while the DLP exceeded national DRLs in 2.9 % of the examinations. Between different CT protocols of the same body region, radiation exposure varied up to 50 % of the DRLs. Conclusion: The implemented cloud-based CT dose monitoring based on the DICOM-SR enables automated benchmarking in regard to national DRLs. Overall the local dose exposure from CT reached approximately 50 % of these DRLs indicating that DRL actualization as well as protocol-specific DRLs are desirable. The cloud-based approach enables multi-center dose monitoring and offers great potential to further optimize radiation exposure in radiological departments.

  3. SU-C-BRD-06: Sensitivity Study of An Automated System to Acquire and Analyze EPID Exit Dose Images

    Energy Technology Data Exchange (ETDEWEB)

    Olch, A; Zhuang, A [University of Southern California, Los Angeles, CA (United States)

    2015-06-15

    Purpose: The dosimetric consequences of errors in patient setup or beam delivery and anatomical changes are not readily known. A new product, PerFRACTION (Sun Nuclear Corporation), is designed to detect these errors by comparing the EPID exit dose image from each field of each fraction to those from baseline fraction images. This work investigates the sensitivity of PerFRACTION to detect the deviation of induced errors in a variety of realistic scenarios. Methods: Eight plans were created mimicking potential delivery or setup errors. The plans consisted of a nominal field and the field with an induced error. These were used to irradiate the EPID simulating multiple fractions with and without the error. Integrated EPID images were acquired in clinical mode and saved in ARIA. PerFRACTION automatically pulls the images into its database and performs the user defined comparison. In some cases, images were manually pushed to PerFRACTION. We varied the distance-to-agreement or dose tolerance until PerFRACTION showed failing pixels in the affected region and recorded the values. We induced errors of 1mm and greater in jaw, MLC, and couch position, 2 degree collimation rotation (patient yaw), and 0.5% to 1.5% in machine output. Both static and arc fields with the rails in or out were also acquired and compared. Results: PerFRACTION detected position errors of the jaws, MLC, and couch with an accuracy of better than 0.5 mm, and 0.2 degrees for collimator and gantry error. PerFRACTION detected a machine output error within 0.2% and detected the change in rail position. Conclusion: A new automated system for monitoring daily treatments for machine or patient variations from the first fraction using integrated EPID images was found to be sensitive enough to detect small positional, angular, and dosimetric errors within 0.5mm, 0.2 degrees, and 0.2%, respectively. Sun Nuclear Corporation has provided a software license for the product described.

  4. Prescription habits of dispensing and non-dispensing doctors in Zimbabwe

    DEFF Research Database (Denmark)

    Trap, Birna; Hansen, Ebba Holme; Hogerzeil, Hans V

    2002-01-01

    , race, place of education, location of practice and patients seen per day showed that dispensing by doctors was associated with less clinically and economically appropriate prescribing. These findings suggest that the quality of health care--as related to drug use, patient safety and treatment cost......The number of dispensing doctors has increased in the last decade, but the implication of this trend on the quality of health care and drug use is unknown. We present a comparative drug utilization study of 29 dispensing doctors and 28 non-dispensing doctors in Zimbabwe based on standard indicators...... developed by the World Health Organization. Dispensing doctors prescribed significantly more drugs per patient than non-dispensing doctors (2.3 versus 1.7), injected more patients (28.4% versus 9.5%), and prescribed more antibiotics (0.72 versus 0.54) and mixtures (0.43 versus 0.25) per encounter...

  5. SU-G-201-03: Automation of High Dose Rate Brachytherapy Quality Assurance: Development of a Radioluminescent Detection System for Simultaneous Detection of Activity, Timing, and Positioning

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, C; Xing, L; Fahimian, B [Stanford University, Stanford, CA (United States)

    2016-06-15

    Purpose: Accuracy of positioning, timing and activity is of critical importance for High Dose Rate (HDR) brachytherapy delivery. Respective measurements via film autoradiography, stop-watches and well chambers can be cumbersome, crude or lack dynamic source evaluation capabilities. To address such limitations, a single device radioluminescent detection system enabling automated real-time quantification of activity, position and timing accuracy is presented and experimentally evaluated. Methods: A radioluminescent sheet was fabricated by mixing Gd?O?S:Tb with PDMS and incorporated into a 3D printed device where it was fixated below a CMOS digital camera. An Ir-192 HDR source (VS2000, VariSource iX) with an effective active length of 5 mm was introduced using a 17-gauge stainless steel needle below the sheet. Pixel intensity values for determining activity were taken from an ROI centered on the source location. A calibration curve relating intensity values to activity was generated and used to evaluate automated activity determination with data gathered over 6 weeks. Positioning measurements were performed by integrating images for an entire delivery and fitting peaks to the resulting profile. Timing measurements were performed by evaluating source location and timestamps from individual images. Results: Average predicted activity error over 6 weeks was .35 ± .5%. The distance between four dwell positions was determined by the automated system to be 1.99 ± .02 cm. The result from autoradiography was 2.00 ± .03 cm. The system achieved a time resolution of 10 msec and determined the dwell time to be 1.01 sec ± .02 sec. Conclusion: The system was able to successfully perform automated detection of activity, positioning and timing concurrently under a single setup. Relative to radiochromic and radiographic film-based autoradiography, which can only provide a static evaluation positioning, optical detection of temporary radiation induced luminescence enables dynamic

  6. TU-H-207A-09: An Automated Technique for Estimating Patient-Specific Regional Imparted Energy and Dose From TCM CT Exams Across 13 Protocols

    International Nuclear Information System (INIS)

    Sanders, J; Tian, X; Segars, P; Boone, J; Samei, E

    2016-01-01

    Purpose: To develop an automated technique for estimating patient-specific regional imparted energy and dose from tube current modulated (TCM) computed tomography (CT) exams across a diverse set of head and body protocols. Methods: A library of 58 adult computational anthropomorphic extended cardiac-torso (XCAT) phantoms were used to model a patient population. A validated Monte Carlo program was used to simulate TCM CT exams on the entire library of phantoms for three head and 10 body protocols. The net imparted energy to the phantoms, normalized by dose length product (DLP), and the net tissue mass in each of the scan regions were computed. A knowledgebase containing relationships between normalized imparted energy and scanned mass was established. An automated computer algorithm was written to estimate the scanned mass from actual clinical CT exams. The scanned mass estimate, DLP of the exam, and knowledgebase were used to estimate the imparted energy to the patient. The algorithm was tested on 20 chest and 20 abdominopelvic TCM CT exams. Results: The normalized imparted energy increased with increasing kV for all protocols. However, the normalized imparted energy was relatively unaffected by the strength of the TCM. The average imparted energy was 681 ± 376 mJ for abdominopelvic exams and 274 ± 141 mJ for chest exams. Overall, the method was successful in providing patientspecific estimates of imparted energy for 98% of the cases tested. Conclusion: Imparted energy normalized by DLP increased with increasing tube potential. However, the strength of the TCM did not have a significant effect on the net amount of energy deposited to tissue. The automated program can be implemented into the clinical workflow to provide estimates of regional imparted energy and dose across a diverse set of clinical protocols.

  7. Automated tube voltage adaptation in head and neck computed tomography between 120 and 100 kV: effects on image quality and radiation dose.

    Science.gov (United States)

    May, Matthias S; Kramer, Manuel R; Eller, Achim; Wuest, Wolfgang; Scharf, Michael; Brand, Michael; Saake, Marc; Schmidt, Bernhard; Uder, Michael; Lell, Michael M

    2014-09-01

    Low tube voltage allows for computed tomography (CT) imaging with increased iodine contrast at reduced radiation dose. We sought to evaluate the image quality and potential dose reduction using a combination of attenuation based tube current modulation (TCM) and automated tube voltage adaptation (TVA) between 100 and 120 kV in CT of the head and neck. One hundred thirty consecutive patients with indication for head and neck CT were examined with a 128-slice system capable of TCM and TVA. Reference protocol was set at 120 kV. Tube voltage was reduced to 100 kV whenever proposed by automated analysis of the localizer. An additional small scan aligned to the jaw was performed at a fixed 120 kV setting. Image quality was assessed by two radiologists on a standardized Likert-scale and measurements of signal- (SNR) and contrast-to-noise ratio (CNR). Radiation dose was assessed as CTDIvol. Diagnostic image quality was excellent in both groups and did not differ significantly (p = 0.34). Image noise in the 100 kV data was increased and SNR decreased (17.8/9.6) in the jugular veins and the sternocleidomastoid muscle when compared to 120 kV (SNR 24.4/10.3), but not in fatty tissue and air. However, CNR did not differ statistically significant between 100 (23.5/14.4/9.4) and 120 kV data (24.2/15.3/8.6) while radiation dose was decreased by 7-8%. TVA between 100 and 120 kV in combination with TCM led to a radiation dose reduction compared to TCM alone, while keeping CNR constant though maintaining diagnostic image quality.

  8. Automated tube voltage adaptation in head and neck computed tomography between 120 and 100 kV: effects on image quality and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    May, Matthias S.; Uder, Michael; Lell, Michael M. [University Hospital Erlangen, Department of Radiology, Erlangen (Germany); University Erlangen, Imaging Science Institute, Erlangen (Germany); Kramer, Manuel R.; Eller, Achim; Wuest, Wolfgang; Scharf, Michael; Brand, Michael; Saake, Marc [University Hospital Erlangen, Department of Radiology, Erlangen (Germany); Schmidt, Bernhard [Siemens Healthcare, Erlangen (Germany)

    2014-09-15

    Low tube voltage allows for computed tomography (CT) imaging with increased iodine contrast at reduced radiation dose. We sought to evaluate the image quality and potential dose reduction using a combination of attenuation based tube current modulation (TCM) and automated tube voltage adaptation (TVA) between 100 and 120 kV in CT of the head and neck. One hundred thirty consecutive patients with indication for head and neck CT were examined with a 128-slice system capable of TCM and TVA. Reference protocol was set at 120 kV. Tube voltage was reduced to 100 kV whenever proposed by automated analysis of the localizer. An additional small scan aligned to the jaw was performed at a fixed 120 kV setting. Image quality was assessed by two radiologists on a standardized Likert-scale and measurements of signal- (SNR) and contrast-to-noise ratio (CNR). Radiation dose was assessed as CTDI{sub vol}. Diagnostic image quality was excellent in both groups and did not differ significantly (p = 0.34). Image noise in the 100 kV data was increased and SNR decreased (17.8/9.6) in the jugular veins and the sternocleidomastoid muscle when compared to 120 kV (SNR 24.4/10.3), but not in fatty tissue and air. However, CNR did not differ statistically significant between 100 (23.5/14.4/9.4) and 120 kV data (24.2/15.3/8.6) while radiation dose was decreased by 7-8 %. TVA between 100 and 120 kV in combination with TCM led to a radiation dose reduction compared to TCM alone, while keeping CNR constant though maintaining diagnostic image quality. (orig.)

  9. What motivates antibiotic dispensing in accredited drug dispensing outlets in Tanzania? A qualitative study.

    Science.gov (United States)

    Dillip, Angel; Embrey, Martha; Shekalaghe, Elizabeth; Ross-Degnan, Dennis; Vialle-Valentin, Catherine; Kimatta, Suleiman; Liana, Jafary; Rutta, Edmund; Valimba, Richard; Chalker, John

    2015-01-01

    Tanzania introduced the accredited drug dispensing outlet (ADDO) program more than a decade ago. Previous evaluations have generally shown that ADDOs meet defined standards of practice better than non-accredited outlets. However, ADDOs still face challenges with overuse of antibiotics for acute respiratory infections (ARI) and simple diarrhea, which contributes to the emergence of drug resistance. This study aimed to explore the attitudes of ADDO owners and dispensers toward antibiotic dispensing and to learn how accreditation has influenced their dispensing behavior. The study used a qualitative approach. We conducted in-depth interviews with ADDO owners and dispensers in Ruvuma and Tanga regions where the government implemented the ADDO program under centralized and decentralized approaches, respectively; a secondary aim was to compare differences between the two regions. Findings indicate that the ADDO program has brought about positive changes in knowledge of dispensing practices. Respondents were able to correctly explain treatment guidelines for ARI and diarrhea. Almost all dispensers and owners indicated that unnecessary use of antibiotics contributed to antimicrobial resistance. Despite this knowledge, translating it to appropriate dispensing practice is still low. Dispensers' behavior is driven by customer demand, habit ("mazoea"), following inappropriate health facility prescriptions, and the need to make a profit. Although the majority of dispensers reported that they had intervened in situations where customers asked for antibiotics unnecessarily, they tended to give in to clients' requests. Small variations were noted between the two study regions; for example, some dispensers in Ruvuma reported sending clients with incorrect prescriptions back to the health facility, a practice that may reflect regional differences in ADDO implementation and in Integrated Management of Childhood Illness training. Dispensers in rural settings reported more challenges

  10. A “dose on demand” Biomarker Generator for automated production of [18F]F− and [18F]FDG

    International Nuclear Information System (INIS)

    Awasthi, V.; Watson, J.; Gali, H.; Matlock, G.; McFarland, A.; Bailey, J.; Anzellotti, A.

    2014-01-01

    The University of Oklahoma—College of Pharmacy has installed the first Biomarker Generator (BG75) comprising a self-shielded 7.5-MeV proton beam positive ion cyclotron and an aseptic automated chemistry production and quality control module for production of [ 18 F]F − and clinical [ 18 F]FDG. Performance, reliability, and safety of the system for the production of “dose on demand” were tested over several months. No-carrier-added [ 18 F]F − was obtained through the 18 O(p,n) 18 F nuclear reaction by irradiation (20–40 min) of a >95% enriched [ 18 O]H 2 O target (280 μl) with a 7.5-MeV proton beam (3.5–5.0 μA). Automated quality control tests were performed on each dose. The HPLC-based analytical methods were validated against USP methods of quality control. [ 18 F]FDG produced by BG75 was tested in a mouse tumor model implanted with H441 human lung adenocarcinoma cells. After initial installment and optimization, the [ 18 F]F − production has been consistent since March 2011 with a maximum production of 400 to 450 mCi in a day. The average yield is 0.61 mCi/min and 0.92 mCi/min at 3.8 µA and 5 µA, respectively. The current target window has held up for over 25 weeks against >400 bombardment cycles. [ 18 F]FDG production has been consistent since June 2012 with an average of six doses/day in an automated synthesis mode (RCY≈50%). The release criteria included USP-specified limits for pH, residual solvents (acetonitrile/ethanol), kryptofix, radiochemical purity/identity, and filter integrity test. The entire automated operation generated minimal radiation exposure hazard to the operator and environment. As expected, [ 18 F]FDG produced by BG75 was found to delineate tumor volume in a mouse model of xenograft tumor. In summary, production and quality control of “[ 18 F]FDG dose on demand” have been accomplished in an automated and safe manner by the first Biomarker Generator. The implementation of a cGMP quality system is under way towards

  11. TH-AB-207A-05: A Fully-Automated Pipeline for Generating CT Images Across a Range of Doses and Reconstruction Methods

    International Nuclear Information System (INIS)

    Young, S; Lo, P; Hoffman, J; Wahi-Anwar, M; Brown, M; McNitt-Gray, M; Noo, F

    2016-01-01

    Purpose: To evaluate the robustness of CAD or Quantitative Imaging methods, they should be tested on a variety of cases and under a variety of image acquisition and reconstruction conditions that represent the heterogeneity encountered in clinical practice. The purpose of this work was to develop a fully-automated pipeline for generating CT images that represent a wide range of dose and reconstruction conditions. Methods: The pipeline consists of three main modules: reduced-dose simulation, image reconstruction, and quantitative analysis. The first two modules of the pipeline can be operated in a completely automated fashion, using configuration files and running the modules in a batch queue. The input to the pipeline is raw projection CT data; this data is used to simulate different levels of dose reduction using a previously-published algorithm. Filtered-backprojection reconstructions are then performed using FreeCT_wFBP, a freely-available reconstruction software for helical CT. We also added support for an in-house, model-based iterative reconstruction algorithm using iterative coordinate-descent optimization, which may be run in tandem with the more conventional recon methods. The reduced-dose simulations and image reconstructions are controlled automatically by a single script, and they can be run in parallel on our research cluster. The pipeline was tested on phantom and lung screening datasets from a clinical scanner (Definition AS, Siemens Healthcare). Results: The images generated from our test datasets appeared to represent a realistic range of acquisition and reconstruction conditions that we would expect to find clinically. The time to generate images was approximately 30 minutes per dose/reconstruction combination on a hybrid CPU/GPU architecture. Conclusion: The automated research pipeline promises to be a useful tool for either training or evaluating performance of quantitative imaging software such as classifiers and CAD algorithms across the range

  12. TH-AB-207A-05: A Fully-Automated Pipeline for Generating CT Images Across a Range of Doses and Reconstruction Methods

    Energy Technology Data Exchange (ETDEWEB)

    Young, S; Lo, P; Hoffman, J; Wahi-Anwar, M; Brown, M; McNitt-Gray, M [UCLA School of Medicine, Los Angeles, CA (United States); Noo, F [University of Utah, Salt Lake City, UT (United States)

    2016-06-15

    Purpose: To evaluate the robustness of CAD or Quantitative Imaging methods, they should be tested on a variety of cases and under a variety of image acquisition and reconstruction conditions that represent the heterogeneity encountered in clinical practice. The purpose of this work was to develop a fully-automated pipeline for generating CT images that represent a wide range of dose and reconstruction conditions. Methods: The pipeline consists of three main modules: reduced-dose simulation, image reconstruction, and quantitative analysis. The first two modules of the pipeline can be operated in a completely automated fashion, using configuration files and running the modules in a batch queue. The input to the pipeline is raw projection CT data; this data is used to simulate different levels of dose reduction using a previously-published algorithm. Filtered-backprojection reconstructions are then performed using FreeCT-wFBP, a freely-available reconstruction software for helical CT. We also added support for an in-house, model-based iterative reconstruction algorithm using iterative coordinate-descent optimization, which may be run in tandem with the more conventional recon methods. The reduced-dose simulations and image reconstructions are controlled automatically by a single script, and they can be run in parallel on our research cluster. The pipeline was tested on phantom and lung screening datasets from a clinical scanner (Definition AS, Siemens Healthcare). Results: The images generated from our test datasets appeared to represent a realistic range of acquisition and reconstruction conditions that we would expect to find clinically. The time to generate images was approximately 30 minutes per dose/reconstruction combination on a hybrid CPU/GPU architecture. Conclusion: The automated research pipeline promises to be a useful tool for either training or evaluating performance of quantitative imaging software such as classifiers and CAD algorithms across the range

  13. Smart DNA Fabrication Using Sound Waves: Applying Acoustic Dispensing Technologies to Synthetic Biology.

    Science.gov (United States)

    Kanigowska, Paulina; Shen, Yue; Zheng, Yijing; Rosser, Susan; Cai, Yizhi

    2016-02-01

    Acoustic droplet ejection (ADE) technology uses focused acoustic energy to transfer nanoliter-scale liquid droplets with high precision and accuracy. This noncontact, tipless, low-volume dispensing technology minimizes the possibility of cross-contamination and potentially reduces the costs of reagents and consumables. To date, acoustic dispensers have mainly been used in screening libraries of compounds. In this paper, we describe the first application of this powerful technology to the rapidly developing field of synthetic biology, for DNA synthesis and assembly at the nanoliter scale using a Labcyte Echo 550 acoustic dispenser. We were able to successfully downscale PCRs and the popular one-pot DNA assembly methods, Golden Gate and Gibson assemblies, from the microliter to the nanoliter scale with high assembly efficiency, which effectively cut the reagent cost by 20- to 100-fold. We envision that acoustic dispensing will become an instrumental technology in synthetic biology, in particular in the era of DNA foundries. © 2015 Society for Laboratory Automation and Screening.

  14. Methods for dispensing mercury into devices

    Science.gov (United States)

    Grossman, Mark W.; George, William A.

    1987-04-28

    A process for dispensing mercury into devices which requires mercury. Mercury is first electrolytically separated from either HgO or Hg.sub.2 Cl.sub.2 and plated onto a cathode wire. The cathode wire is then placed into a device requiring mercury.

  15. Alcohol Dispenser Training in Amherst Massachusetts

    Science.gov (United States)

    Riccelli, Carlene

    1986-01-01

    Reviews efforts of the Alcohol Dispenser Training program in Amherst, Massachusetts over a five-year period. Evaluations indicate that participants agree that training is worthwhile, that they are more aware of the effects of alcohol on their patrons, and that they have better knowledge of appropriate strategies for preventing intoxication of…

  16. PROJECT OF COAGULANT DISPENSER IN PULVERIZATION AERATOR WITH WIND DRIVE

    Directory of Open Access Journals (Sweden)

    Ewa Osuch

    2017-09-01

    Full Text Available Lakes are one of most important freshwater ecosystems, playing significant role in functioning of nature and human economy. Swarzędzkie Lake is good example of ecosystem, which in last half-century was exposed to the influence of strong anthropopressure. Direct inflow of sewage with large number of biogens coming to the lake with water of inflows caused distinct disturbance of its functioning. In autumn 2011 restoration begined on Swarzędzkie Lake for reduction of lake trophy and improvement of water quality. For achieving better and quicker effect, simultaneously combination of some methods was applied, among others method of oxygenation of over-bottom water with help of pulverization aerator and method of precise inactivation of phosphorus in water depths. Characterization and analysis of improved coagulant dispenser applying active substance only during work of pulverization aerator is the aim of this thesis. Principle of dispenser work, its structure and location in pulverization aerator were explained. It was stated, that introduction to water a factor initiating process of phosphorus inactivation causes significant reduction of mineral phosphorus in water and size of coagulant dose correlates with intensity of work of pulverization aerator with wind drive.

  17. 21 CFR 872.3080 - Mercury and alloy dispenser.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Mercury and alloy dispenser. 872.3080 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3080 Mercury and alloy dispenser. (a) Identification. A mercury and alloy dispenser is a device with a spring-activated valve intended to measure and...

  18. SU-D-16A-02: A Novel Methodology for Accurate, Semi-Automated Delineation of Oral Mucosa for Radiation Therapy Dose-Response Studies

    International Nuclear Information System (INIS)

    Dean, J; Welsh, L; Gulliford, S; Harrington, K; Nutting, C

    2014-01-01

    Purpose: The significant morbidity caused by radiation-induced acute oral mucositis means that studies aiming to elucidate dose-response relationships in this tissue are a high priority. However, there is currently no standardized method for delineating the mucosal structures within the oral cavity. This report describes the development of a methodology to delineate the oral mucosa accurately on CT scans in a semi-automated manner. Methods: An oral mucosa atlas for automated segmentation was constructed using the RayStation Atlas-Based Segmentation (ABS) module. A radiation oncologist manually delineated the full surface of the oral mucosa on a planning CT scan of a patient receiving radiotherapy (RT) to the head and neck region. A 3mm fixed annulus was added to incorporate the mucosal wall thickness. This structure was saved as an atlas template. ABS followed by model-based segmentation was performed on four further patients sequentially, adding each patient to the atlas. Manual editing of the automatically segmented structure was performed. A dose comparison between these contours and previously used oral cavity volume contours was performed. Results: The new approach was successful in delineating the mucosa, as assessed by an experienced radiation oncologist, when applied to a new series of patients receiving head and neck RT. Reductions in the mean doses obtained when using the new delineation approach, compared with the previously used technique, were demonstrated for all patients (median: 36.0%, range: 25.6% – 39.6%) and were of a magnitude that might be expected to be clinically significant. Differences in the maximum dose that might reasonably be expected to be clinically significant were observed for two patients. Conclusion: The method developed provides a means of obtaining the dose distribution delivered to the oral mucosa more accurately than has previously been achieved. This will enable the acquisition of high quality dosimetric data for use in

  19. SU-E-I-89: Assessment of CT Radiation Dose and Image Quality for An Automated Tube Potential Selection Algorithm Using Pediatric Anthropomorphic and ACR Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Mahmood, U; Erdi, Y; Wang, W [Memorial Sloan Kettering Cancer Center, NY, NY (United States)

    2014-06-01

    Purpose: To assess the impact of General Electrics automated tube potential algorithm, kV assist (kVa) on radiation dose and image quality, with an emphasis on optimizing protocols based on noise texture. Methods: Radiation dose was assessed by inserting optically stimulated luminescence dosimeters (OSLs) throughout the body of a pediatric anthropomorphic phantom (CIRS). The baseline protocol was: 120 kVp, 80 mA, 0.7s rotation time. Image quality was assessed by calculating the contrast to noise ratio (CNR) and noise power spectrum (NPS) from the ACR CT accreditation phantom. CNRs were calculated according to the steps described in ACR CT phantom testing document. NPS was determined by taking the 3D FFT of the uniformity section of the ACR phantom. NPS and CNR were evaluated with and without kVa and for all available adaptive iterative statistical reconstruction (ASiR) settings, ranging from 0 to 100%. Each NPS was also evaluated for its peak frequency difference (PFD) with respect to the baseline protocol. Results: For the baseline protocol, CNR was found to decrease from 0.460 ± 0.182 to 0.420 ± 0.057 when kVa was activated. When compared against the baseline protocol, the PFD at ASiR of 40% yielded a decrease in noise magnitude as realized by the increase in CNR = 0.620 ± 0.040. The liver dose decreased by 30% with kVa activation. Conclusion: Application of kVa reduces the liver dose up to 30%. However, reduction in image quality for abdominal scans occurs when using the automated tube voltage selection feature at the baseline protocol. As demonstrated by the CNR and NPS analysis, the texture and magnitude of the noise in reconstructed images at ASiR 40% was found to be the same as our baseline images. We have demonstrated that 30% dose reduction is possible when using 40% ASiR with kVa in pediatric patients.

  20. SU-E-I-89: Assessment of CT Radiation Dose and Image Quality for An Automated Tube Potential Selection Algorithm Using Pediatric Anthropomorphic and ACR Phantoms

    International Nuclear Information System (INIS)

    Mahmood, U; Erdi, Y; Wang, W

    2014-01-01

    Purpose: To assess the impact of General Electrics automated tube potential algorithm, kV assist (kVa) on radiation dose and image quality, with an emphasis on optimizing protocols based on noise texture. Methods: Radiation dose was assessed by inserting optically stimulated luminescence dosimeters (OSLs) throughout the body of a pediatric anthropomorphic phantom (CIRS). The baseline protocol was: 120 kVp, 80 mA, 0.7s rotation time. Image quality was assessed by calculating the contrast to noise ratio (CNR) and noise power spectrum (NPS) from the ACR CT accreditation phantom. CNRs were calculated according to the steps described in ACR CT phantom testing document. NPS was determined by taking the 3D FFT of the uniformity section of the ACR phantom. NPS and CNR were evaluated with and without kVa and for all available adaptive iterative statistical reconstruction (ASiR) settings, ranging from 0 to 100%. Each NPS was also evaluated for its peak frequency difference (PFD) with respect to the baseline protocol. Results: For the baseline protocol, CNR was found to decrease from 0.460 ± 0.182 to 0.420 ± 0.057 when kVa was activated. When compared against the baseline protocol, the PFD at ASiR of 40% yielded a decrease in noise magnitude as realized by the increase in CNR = 0.620 ± 0.040. The liver dose decreased by 30% with kVa activation. Conclusion: Application of kVa reduces the liver dose up to 30%. However, reduction in image quality for abdominal scans occurs when using the automated tube voltage selection feature at the baseline protocol. As demonstrated by the CNR and NPS analysis, the texture and magnitude of the noise in reconstructed images at ASiR 40% was found to be the same as our baseline images. We have demonstrated that 30% dose reduction is possible when using 40% ASiR with kVa in pediatric patients

  1. Cone beam CT with zonal filters for simultaneous dose reduction, improved target contrast and automated set-up in radiotherapy

    International Nuclear Information System (INIS)

    Moore, C J; Marchant, T E; Amer, A M

    2006-01-01

    Cone beam CT (CBCT) using a zonal filter is introduced. The aims are reduced concomitant imaging dose to the patient, simultaneous control of body scatter for improved image quality in the tumour target zone and preserved set-up detail for radiotherapy. Aluminium transmission diaphragms added to the CBCT x-ray tube of the Elekta Synergy TM linear accelerator produced an unattenuated beam for a central 'target zone' and a partially attenuated beam for an outer 'set-up zone'. Imaging doses and contrast noise ratios (CNR) were measured in a test phantom for transmission diaphragms 12 and 24 mm thick, for 5 and 10 cm long target zones. The effect on automatic registration of zonal CBCT to conventional CT was assessed relative to full-field and lead-collimated images of an anthropomorphic phantom. Doses along the axis of rotation were reduced by up to 50% in both target and set-up zones, and weighted dose (two thirds surface dose plus one third central dose) was reduced by 10-20% for a 10 cm long target zone. CNR increased by up to 15% in zonally filtered CBCT images compared to full-field images. Automatic image registration remained as robust as that with full-field images and was superior to CBCT coned down using lead-collimation. Zonal CBCT significantly reduces imaging dose and is expected to benefit radiotherapy through improved target contrast, required to assess target coverage, and wide-field edge detail, needed for robust automatic measurement of patient set-up error

  2. Automated tube voltage selection for radiation dose and contrast medium reduction at coronary CT angiography using 3{sup rd} generation dual-source CT

    Energy Technology Data Exchange (ETDEWEB)

    Mangold, Stefanie [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Wichmann, Julian L. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Schoepf, U.J. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Poole, Zachary B.; Varga-Szemes, Akos; De Cecco, Carlo N. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Canstein, Christian [Siemens Medical Solutions, Malvern, PA (United States); Caruso, Damiano [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Rome ' ' Sapienza' ' , Department of Radiological Sciences, Oncology and Pathology, Rome (Italy); Bamberg, Fabian; Nikolaou, Konstantin [Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2016-10-15

    To investigate the relationship between automated tube voltage selection (ATVS) and body mass index (BMI) and its effect on image quality and radiation dose of coronary CT angiography (CCTA). We evaluated 272 patients who underwent CCTA with 3{sup rd} generation dual-source CT (DSCT). Prospectively ECG-triggered spiral acquisition was performed with automated tube current selection and advanced iterative reconstruction. Tube voltages were selected by ATVS (70-120 kV). BMI, effective dose (ED), and vascular attenuation in the coronary arteries were recorded. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Five-point scales were used for subjective image quality analysis. Image quality was rated good to excellent in 98.9 % of examinations without significant differences for proximal and distal attenuation (all p ≥.0516), whereas image noise was rated significantly higher at 70 kV compared to ≥100 kV (all p <.0266). However, no significant differences were observed in SNR or CNR at 70-120 kV (all p ≥.0829). Mean ED at 70-120 kV was 1.5 ± 1.2 mSv, 2.4 ± 1.5 mSv, 3.6 ± 2.7 mSv, 5.9 ± 4.0 mSv, 7.9 ± 4.2 mSv, and 10.7 ± 4.1 mSv, respectively (all p ≤.0414). Correlation analysis showed a moderate association between tube voltage and BMI (r =.639). ATVS allows individual tube voltage adaptation for CCTA performed with 3{sup rd} generation DSCT, resulting in significantly decreased radiation exposure while maintaining image quality. (orig.)

  3. Twenty-year trends in benzodiazepine dispensing in the Australian population.

    Science.gov (United States)

    Islam, M M; Conigrave, K M; Day, C A; Nguyen, Y; Haber, P S

    2014-01-01

    Considerable concern has been expressed about overprescribing of benzodiazepines and related harms. Past analyses have relied on World Health Organization-defined daily doses (DDD) which are sometimes out of keeping with clinical usage. This study examines 20-year (1992-2011) trends of benzodiazepine dispensing in Australia using both DDD and Ashton equivalent dose. Data from the Drug Utilisation Sub-Committee and the Pharmaceutical Benefits Scheme (PBS) website were analysed. Trends in number of prescriptions, DDD/1000 people/day and DDD/prescription were examined over time, and between states/territories. In the 20-year period, 174 080 904 scripts were recorded, with temazepam the most dispensed benzodiazepine (35% of scripts), followed by diazepam (23%). Overall recorded utilisation fell from 27.7 DDD/1000 people/day in 1992 to 20.8 in 2011 (24.9% decrease). There were striking changes in use of individual benzodiazepines over time, with reductions in oxazepam and flunitrazepam and dramatic increases in alprazolam. Since 1998, there has been a steady increase, albeit modest, in per script DDD. The DDD/1000 people/day for items dispensed through PBS/Repatriaton-PBS was highest in Tasmania and lowest in Northern Territory. Despite a modest overall decline in the amount of benzodiazepine dispensed, the level of use is still likely to reflect relative over-prescribing given the paucity of accepted indications for long-term use. Since 1998, there was a polynomial increase in quantity dispensed per script. The WHO-defined DDD for clonazepam seems inappropriate and could impede monitoring of its abuse. Other problems include lack of national data for medications not subsidised on PBS/Repatriation PBS. A broad policy approach is required, not one which targets only one particular benzodiazepine. © 2013 The Authors; Internal Medicine Journal © 2013 Royal Australasian College of Physicians.

  4. Digital Imaging and Piezo-dispenser Actuator in Automatic Flocculation Control

    Directory of Open Access Journals (Sweden)

    Jani TOMPERI

    2012-01-01

    Full Text Available This study presents an image-based on-line control system for a coiled pipe flocculator. A digital imaging technique developed previously is utilized to measure the characteristic floc size and a high-pressure piezo-dispenser is introduced for accurate dosing and rapid mixing of the flocculant. The controller is a conventional PI controller. Step change experiments on feed water quality, flow rate and desired floc size have been carried out for controller tuning and testing. The paper shows that the piezo-dispenser provides better flocculation results than a conventional dosing pump, and the flocculation result can be automatically controlled even when the feed water quality rapidly changes. The proposed flocculator is a simple, inexpensive and practical system for long-term laboratory tests to investigate the functionality of flocculants on varying feed waters.

  5. Quality assurance in CT: implementation of the updated national diagnostic reference levels using an automated CT dose monitoring system.

    Science.gov (United States)

    Appel, E; Kröpil, P; Bethge, O T; Aissa, J; Thomas, C; Antoch, G; Boos, J

    2018-03-20

    To evaluate the implementation of the updated computed tomography (CT) diagnostic reference levels (DRLs) from the German Federal Office for Radiation Protection into clinical routine using an automatic CT dose monitoring system. CT radiation exposure was analysed before and after implementing the updated national DRLs into routine clinical work in 2016. After the implementation process, institutional CT protocols were mapped to the anatomical regions for which DRLs were provided. Systematically, protocols that exceeded the thresholds were optimised and analysed in detail. The CT radiation output parameters analysed were volumetric CT dose index (CTDIvol) and dose-length product (DLP). Three radiologists evaluated subjective image quality using a three-point Likert scale. The study included 94,258 CT series (from 27,103 CT examinations) in adult patients performed in 2016. When averaged over all body regions with available DRL, institutional CTDIvol/DLP values were always below the DRLs (65.2±32.9%/67.3±41.5% initially; 59.4±32%/60.5±39.9% after optimisation). Values exceeding the national DRLs were found for pelvis (n=268; CTDIvol 107.7±65.7%/DLP 106.3±79.3%), lumbar spine (n=91; 160.8±74.7%/175.2±104.1%), and facial bones (n=527; 108±39%/152.7±75.7%). After optimisation, CTDIvol and DLP were 87.9±73%/87.8±80.8% for the pelvis, 67.8±33.2%/74.5±50.6% for the lumbar spine and 95.1±45.8%/133.3±74.6% for the viscerocranium. An automatic CT dose monitoring system enabled not only comprehensive monitoring of a DRL implementation process but can also help to optimise radiation exposure. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  6. Robotic liquid handling and automation in epigenetics.

    Science.gov (United States)

    Gaisford, Wendy

    2012-10-01

    Automated liquid-handling robots and high-throughput screening (HTS) are widely used in the pharmaceutical industry for the screening of large compound libraries, small molecules for activity against disease-relevant target pathways, or proteins. HTS robots capable of low-volume dispensing reduce assay setup times and provide highly accurate and reproducible dispensing, minimizing variation between sample replicates and eliminating the potential for manual error. Low-volume automated nanoliter dispensers ensure accuracy of pipetting within volume ranges that are difficult to achieve manually. In addition, they have the ability to potentially expand the range of screening conditions from often limited amounts of valuable sample, as well as reduce the usage of expensive reagents. The ability to accurately dispense lower volumes provides the potential to achieve a greater amount of information than could be otherwise achieved using manual dispensing technology. With the emergence of the field of epigenetics, an increasing number of drug discovery companies are beginning to screen compound libraries against a range of epigenetic targets. This review discusses the potential for the use of low-volume liquid handling robots, for molecular biological applications such as quantitative PCR and epigenetics.

  7. A Simulated Learning Environment for Teaching Medicine Dispensing Skills.

    Science.gov (United States)

    McDowell, Jenny; Styles, Kim; Sewell, Keith; Trinder, Peta; Marriott, Jennifer; Maher, Sheryl; Naidu, Som

    2016-02-25

    To develop an authentic simulation of the professional practice dispensary context for students to develop their dispensing skills in a risk-free environment. A development team used an Agile software development method to create MyDispense, a web-based simulation. Modeled on virtual learning environments elements, the software employed widely available standards-based technologies to create a virtual community pharmacy environment. Assessment. First-year pharmacy students who used the software in their tutorials, were, at the end of the second semester, surveyed on their prior dispensing experience and their perceptions of MyDispense as a tool to learn dispensing skills. The dispensary simulation is an effective tool for helping students develop dispensing competency and knowledge in a safe environment.

  8. Dispenser printed electroluminescent lamps on textiles for smart fabric applications

    Science.gov (United States)

    de Vos, Marc; Torah, Russel; Tudor, John

    2016-04-01

    Flexible electroluminescent (EL) lamps are fabricated onto woven textiles using a novel dispenser printing process. Dispenser printing utilizes pressurized air to deposit ink onto a substrate through a syringe and nozzle. This work demonstrates the first use of this technology to fabricate EL lamps. The luminance of the dispenser printed EL lamps is compared to screen-printed EL lamps, both printed on textile, and also commercial EL lamps on polyurethane film. The dispenser printed lamps are shown to have a 1.5 times higher luminance than the best performing commercially available lamp, and have a comparable performance to the screen-printed lamps.

  9. Structure Design and Realization of Rapid Medicine Dispensing System

    Science.gov (United States)

    Liu, Xiangquan

    In this paper, the main components and function of rapid medicine dispensing system is analyzed, structure design of automatic feeding device, sloping storeroom, automatic dispensing device and automatic sorting device is completed. The system adopts medicine conveyer working in with manipulator to realize automatic batch supply of the boxed medicine, adopts sloping storeroom as warehouse of medicine to realize dense depositing, adopts dispensing mechanism which includes elevator, turning panel and electric magnet to realize rapid medicine dispensing, adopts sorting conveyor belt and sorting device to send medicine to designated outlet.

  10. 21 CFR 866.2500 - Microtiter diluting and dispensing device.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2500... a mechanical device intended for medical purposes to dispense or serially dilute very small...

  11. Dispenser printed electroluminescent lamps on textiles for smart fabric applications

    International Nuclear Information System (INIS)

    De Vos, Marc; Torah, Russel; Tudor, John

    2016-01-01

    Flexible electroluminescent (EL) lamps are fabricated onto woven textiles using a novel dispenser printing process. Dispenser printing utilizes pressurized air to deposit ink onto a substrate through a syringe and nozzle. This work demonstrates the first use of this technology to fabricate EL lamps. The luminance of the dispenser printed EL lamps is compared to screen-printed EL lamps, both printed on textile, and also commercial EL lamps on polyurethane film. The dispenser printed lamps are shown to have a 1.5 times higher luminance than the best performing commercially available lamp, and have a comparable performance to the screen-printed lamps. (paper)

  12. SU-E-I-81: Assessment of CT Radiation Dose and Image Quality for An Automated Tube Potential Selection Algorithm Using Adult Anthropomorphic and ACR Phantoms

    International Nuclear Information System (INIS)

    Mahmood, U; Erdi, Y; Wang, W

    2014-01-01

    Purpose: To assess the impact of General Electrics (GE) automated tube potential algorithm, kV assist (kVa) on radiation dose and image quality, with an emphasis on optimizing protocols based on noise texture. Methods: Radiation dose was assessed by inserting optically stimulated luminescence dosimeters (OSLs) throughout the body of an adult anthropomorphic phantom (CIRS). The baseline protocol was: 120 kVp, Auto mA (180 to 380 mA), noise index (NI) = 14, adaptive iterative statistical reconstruction (ASiR) of 20%, 0.8s rotation time. Image quality was evaluated by calculating the contrast to noise ratio (CNR) and noise power spectrum (NPS) from the ACR CT accreditation phantom. CNRs were calculated according to the steps described in ACR CT phantom testing document. NPS was determined by taking the 3D FFT of the uniformity section of the ACR phantom. NPS and CNR were evaluated with and without kVa and for all available adaptive iterative statistical reconstruction (ASiR) settings, ranging from 0 to 100%. Each NPS was also evaluated for its peak frequency difference (PFD) with respect to the baseline protocol. Results: The CNR for the adult male was found to decrease from CNR = 0.912 ± 0.045 for the baseline protocol without kVa to a CNR = 0.756 ± 0.049 with kVa activated. When compared against the baseline protocol, the PFD at ASiR of 40% yielded a decrease in noise magnitude as realized by the increase in CNR = 0.903 ± 0.023. The difference in the central liver dose with and without kVa was found to be 0.07%. Conclusion: Dose reduction was insignificant in the adult phantom. As determined by NPS analysis, ASiR of 40% produced images with similar noise texture to the baseline protocol. However, the CNR at ASiR of 40% with kVa fails to meet the current ACR CNR passing requirement of 1.0

  13. SU-E-I-81: Assessment of CT Radiation Dose and Image Quality for An Automated Tube Potential Selection Algorithm Using Adult Anthropomorphic and ACR Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Mahmood, U; Erdi, Y; Wang, W [Memorial Sloan Kettering Cancer Center, NY, NY (United States)

    2014-06-01

    Purpose: To assess the impact of General Electrics (GE) automated tube potential algorithm, kV assist (kVa) on radiation dose and image quality, with an emphasis on optimizing protocols based on noise texture. Methods: Radiation dose was assessed by inserting optically stimulated luminescence dosimeters (OSLs) throughout the body of an adult anthropomorphic phantom (CIRS). The baseline protocol was: 120 kVp, Auto mA (180 to 380 mA), noise index (NI) = 14, adaptive iterative statistical reconstruction (ASiR) of 20%, 0.8s rotation time. Image quality was evaluated by calculating the contrast to noise ratio (CNR) and noise power spectrum (NPS) from the ACR CT accreditation phantom. CNRs were calculated according to the steps described in ACR CT phantom testing document. NPS was determined by taking the 3D FFT of the uniformity section of the ACR phantom. NPS and CNR were evaluated with and without kVa and for all available adaptive iterative statistical reconstruction (ASiR) settings, ranging from 0 to 100%. Each NPS was also evaluated for its peak frequency difference (PFD) with respect to the baseline protocol. Results: The CNR for the adult male was found to decrease from CNR = 0.912 ± 0.045 for the baseline protocol without kVa to a CNR = 0.756 ± 0.049 with kVa activated. When compared against the baseline protocol, the PFD at ASiR of 40% yielded a decrease in noise magnitude as realized by the increase in CNR = 0.903 ± 0.023. The difference in the central liver dose with and without kVa was found to be 0.07%. Conclusion: Dose reduction was insignificant in the adult phantom. As determined by NPS analysis, ASiR of 40% produced images with similar noise texture to the baseline protocol. However, the CNR at ASiR of 40% with kVa fails to meet the current ACR CNR passing requirement of 1.0.

  14. TU-AB-201-02: An Automated Treatment Plan Quality Assurance Program for Tandem and Ovoid High Dose-Rate Brachytherapy

    International Nuclear Information System (INIS)

    Tan, J; Shi, F; Hrycushko, B; Medin, P; Stojadinovic, S; Pompos, A; Yang, M; Albuquerque, K; Jia, X

    2015-01-01

    Purpose: For tandem and ovoid (T&O) HDR brachytherapy in our clinic, it is required that the planning physicist manually capture ∼10 images during planning, perform a secondary dose calculation and generate a report, combine them into a single PDF document, and upload it to a record- and-verify system to prove to an independent plan checker that the case was planned correctly. Not only does this slow down the already time-consuming clinical workflow, the PDF document also limits the number of parameters that can be checked. To solve these problems, we have developed a web-based automatic quality assurance (QA) program. Methods: We set up a QA server accessible through a web- interface. A T&O plan and CT images are exported as DICOMRT files and uploaded to the server. The software checks 13 geometric features, e.g. if the dwell positions are reasonable, and 10 dosimetric features, e.g. secondary dose calculations via TG43 formalism and D2cc to critical structures. A PDF report is automatically generated with errors and potential issues highlighted. It also contains images showing important geometric and dosimetric aspects to prove the plan was created following standard guidelines. Results: The program has been clinically implemented in our clinic. In each of the 58 T&O plans we tested, a 14- page QA report was automatically generated. It took ∼45 sec to export the plan and CT images and ∼30 sec to perform the QA tests and generate the report. In contrast, our manual QA document preparation tooks on average ∼7 minutes under optimal conditions and up to 20 minutes when mistakes were made during the document assembly. Conclusion: We have tested the efficiency and effectiveness of an automated process for treatment plan QA of HDR T&O cases. This software was shown to improve the workflow compared to our conventional manual approach

  15. TU-AB-201-02: An Automated Treatment Plan Quality Assurance Program for Tandem and Ovoid High Dose-Rate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Tan, J; Shi, F; Hrycushko, B; Medin, P; Stojadinovic, S; Pompos, A; Yang, M; Albuquerque, K; Jia, X [The University of Texas Southwestern Medical Ctr, Dallas, TX (United States)

    2015-06-15

    Purpose: For tandem and ovoid (T&O) HDR brachytherapy in our clinic, it is required that the planning physicist manually capture ∼10 images during planning, perform a secondary dose calculation and generate a report, combine them into a single PDF document, and upload it to a record- and-verify system to prove to an independent plan checker that the case was planned correctly. Not only does this slow down the already time-consuming clinical workflow, the PDF document also limits the number of parameters that can be checked. To solve these problems, we have developed a web-based automatic quality assurance (QA) program. Methods: We set up a QA server accessible through a web- interface. A T&O plan and CT images are exported as DICOMRT files and uploaded to the server. The software checks 13 geometric features, e.g. if the dwell positions are reasonable, and 10 dosimetric features, e.g. secondary dose calculations via TG43 formalism and D2cc to critical structures. A PDF report is automatically generated with errors and potential issues highlighted. It also contains images showing important geometric and dosimetric aspects to prove the plan was created following standard guidelines. Results: The program has been clinically implemented in our clinic. In each of the 58 T&O plans we tested, a 14- page QA report was automatically generated. It took ∼45 sec to export the plan and CT images and ∼30 sec to perform the QA tests and generate the report. In contrast, our manual QA document preparation tooks on average ∼7 minutes under optimal conditions and up to 20 minutes when mistakes were made during the document assembly. Conclusion: We have tested the efficiency and effectiveness of an automated process for treatment plan QA of HDR T&O cases. This software was shown to improve the workflow compared to our conventional manual approach.

  16. Automated Breast Density Computation in Digital Mammography and Digital Breast Tomosynthesis: Influence on Mean Glandular Dose and BIRADS Density Categorization.

    Science.gov (United States)

    Castillo-García, Maria; Chevalier, Margarita; Garayoa, Julia; Rodriguez-Ruiz, Alejandro; García-Pinto, Diego; Valverde, Julio

    2017-07-01

    The study aimed to compare the breast density estimates from two algorithms on full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) and to analyze the clinical implications. We selected 561 FFDM and DBT examinations from patients without breast pathologies. Two versions of a commercial software (Quantra 2D and Quantra 3D) calculated the volumetric breast density automatically in FFDM and DBT, respectively. Other parameters such as area breast density and total breast volume were evaluated. We compared the results from both algorithms using the Mann-Whitney U non-parametric test and the Spearman's rank coefficient for data correlation analysis. Mean glandular dose (MGD) was calculated following the methodology proposed by Dance et al. Measurements with both algorithms are well correlated (r ≥ 0.77). However, there are statistically significant differences between the medians (P density median values from FFDM are, respectively, 8% and 77% higher than DBT estimations. Both algorithms classify 35% and 55% of breasts into BIRADS (Breast Imaging-Reporting and Data System) b and c categories, respectively. There are no significant differences between the MGD calculated using the breast density from each algorithm. DBT delivers higher MGD than FFDM, with a lower difference (5%) for breasts in the BIRADS d category. MGD is, on average, 6% higher than values obtained with the breast glandularity proposed by Dance et al. Breast density measurements from both algorithms lead to equivalent BIRADS classification and MGD values, hence showing no difference in clinical outcomes. The median MGD values of FFDM and DBT examinations are similar for dense breasts (BIRADS d category). Published by Elsevier Inc.

  17. Providers′ knowledge, attitude and dispensing practices of E-Pills in government dispensaries of south district in Delhi, India

    Directory of Open Access Journals (Sweden)

    Kishore Vertika

    2010-01-01

    Full Text Available Background: South Delhi is one of the well developed districts in the capital with best public health care facilities. Knowledge, attitude and dispensing practices of emergency contraceptive pills (E-pills were assessed among health care providers of government dispensaries in South Delhi. Study Design: A descriptive epidemiological study. Materials and Methods: Both medical and paramedical (n = 428 providers in 63 government health care facilities were interviewed between August to December 2007 using a semi-structured interview schedule. Results: Among the different categories of the providers, medical officers were observed to be most knowledgeable about E-pills and the pharmacists were the least. The correct prescribed dose of E-pill was known only to 32% of the providers while 49% knew about its right time of intake. Misconceptions and apprehensions for promoting its use were very much prevalent even among medical officers as majority felt that open access to E-pills would increase promiscuity. The dispensing practice of providers was found positively ( P < 0.05 correlated with their knowledge. Training resulted a significant ( P < 0.05 improvement in knowledge, attitude and dispensing practice of the providers. Knowledge and training combined together contributed 35% to the dispensing practice (R 2 = 0.35. Conclusion: Besides knowledge, behavior change communication strategies should form a part of the training curricula of health care providers that would help to improve the dispensing practice of E-pills.

  18. Evaluation and remediation of bulk soap dispensers for biofilm.

    Science.gov (United States)

    Lorenz, Lindsey A; Ramsay, Bradley D; Goeres, Darla M; Fields, Matthew W; Zapka, Carrie A; Macinga, David R

    2012-01-01

    Recent studies evaluating bulk soap in public restroom soap dispensers have demonstrated up to 25% of open refillable bulk-soap dispensers were contaminated with ~ 6 log(10)(CFU ml(-1)) heterotrophic bacteria. In this study, plastic counter-mounted, plastic wall-mounted and stainless steel wall-mounted dispensers were analyzed for suspended and biofilm bacteria using total cell and viable plate counts. Independent of dispenser type or construction material, the bulk soap was contaminated with 4-7 log(10)(CFU ml(-1)) bacteria, while 4-6 log(10)(CFU cm(-2)) biofilm bacteria were isolated from the inside surfaces of the dispensers (n = 6). Dispenser remediation studies, including a 10 min soak with 5000 mg l(-1) sodium hypochlorite, were then conducted to determine the efficacy of cleaning and disinfectant procedures against established biofilms. The testing showed that contamination of the bulk soap returned to pre-test levels within 7-14 days. These results demonstrate biofilm is present in contaminated bulk-soap dispensers and remediation studies to clean and sanitize the dispensers are temporary.

  19. Impact of Robotic Dispensing Machines in German Pharmacies on ...

    African Journals Online (AJOL)

    To assess the impact of robotic dispensing machines in community pharmacies on staff efficiency and sales of over-the-counter drugs. Setting: The study was done on 253 community pharmacies in Germany that use a robotic dispensing machine manufactured by ROWA during 2008. Method: Data concerning the financial ...

  20. Anthelmintic drug dispensing in South Africa: An analysis of ...

    African Journals Online (AJOL)

    More than two billion people worldwide are infected with helminths. The primary aim of the study was to evaluate the dispensing patterns of anthelmintic products using dispensing data of South African community pharmacies. A retrospective, cross-sectional drug utilisation study was conducted on a 2013 community ...

  1. 14 CFR 137.39 - Economic poison dispensing.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Economic poison dispensing. 137.39 Section... AIRCRAFT OPERATIONS Operating Rules § 137.39 Economic poison dispensing. (a) Except as provided in... economic poison that is registered with the U.S. Department of Agriculture under the Federal Insecticide...

  2. Trends in radiopharmaceutical dispensing in a regional nuclear pharmacy

    International Nuclear Information System (INIS)

    Basmadjian, G.P.; Johnston, J.; Barker, K.; Ice, R.D.

    1982-01-01

    Dispensing trends for radiopharmaceuticals at a regional nuclear pharmacy over a 51-month period were studied. dispensing records of a regional nuclear pharmacy were analyzed with a forecasting procedure that uses univariate time data to produce time trends and autoregressive models. The overall number of prescriptions increased from 3500 to 5500 per quarter. Radiopharmaceuticals used in nuclear cardiology studies increased from less than 0.1% to 17.5% of total prescriptions dispensed, while radiopharmaceuticals used for brain imaging showed a steady decline from 29% to 11% of total prescriptions dispensed. The demand for other radiopharmaceuticals increased in areas such as renal studies, bone studies, lung studies, liver-function studies, and 67 Ga tumor-uptake studies, and declined slightly for static liver studies. Changes in dispensing trends for radiopharmaceuticals will continue as the practice of nuclear medicine concentrates more on functional studies and as newer imaging techniques become used for other purposes

  3. Third-generation dual-source CT of the neck using automated tube voltage adaptation in combination with advanced modeled iterative reconstruction: evaluation of image quality and radiation dose

    International Nuclear Information System (INIS)

    Scholtz, Jan-Erik; Wichmann, Julian L.; Huesers, Kristina; Albrecht, Moritz H.; Beeres, Martin; Bauer, Ralf W.; Vogl, Thomas J.; Bodelle, Boris

    2016-01-01

    To evaluate image quality and radiation dose in third-generation dual-source computed tomography (DSCT) of the neck using automated tube voltage adaptation (TVA) with advanced modelled iterative reconstruction (ADMIRE) algorithm. One hundred and sixteen patients were retrospectively evaluated. Group A (n = 59) was examined on second-generation DSCT with automated TVA and filtered back projection. Group B (n = 57) was examined on a third-generation DSCT with automated TVA and ADMIRE. Age, body diameter, attenuation of several anatomic structures, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), radiation dose (CTDI vol ) and size-specific dose estimates (SSDE) were assessed. Diagnostic acceptability was rated by three readers. Age (p = 0.87) and body diameter (p = 0.075) did not differ significantly. Tube voltage in Group A was set automatically to 100 kV for all patients (n = 59), and to 70 kV (n = 2), 80 kV (n = 5), and 90 kV (n = 50) in Group B. Noise was reduced and CNR was increased significantly (p < 0.001). Diagnostic acceptability was rated high in both groups, with better ratings in Group B (p < 0.001). SSDE was reduced by 34 % in Group B (20.38 ± 1.63 mGy vs. 13.04 ± 1.50 mGy, p < 0.001). Combination of automated TVA and ADMIRE in neck CT using third-generation DSCT results in a substantial radiation dose reduction with low noise and increased CNR. (orig.)

  4. Lyplal1 is dispensable for normal fat deposition in mice

    Directory of Open Access Journals (Sweden)

    Rachel A. Watson

    2017-12-01

    Full Text Available Genome-wide association studies (GWAS have detected association between variants in or near the Lysophospholipase-like 1 (LYPLAL1 locus and metabolic traits, including central obesity, fatty liver and waist-to-hip ratio. LYPLAL1 is also known to be upregulated in the adipose tissue of obese patients. However, the physiological role of LYPLAL1 is not understood. To investigate the function of Lyplal1 in vivo we investigated the phenotype of the Lyplal1tm1a(KOMPWtsi homozygous mouse. Body composition was unaltered in Lyplal1 knockout mice as assessed by dual-energy X-ray absorptiometry (DEXA scanning, both on normal chow and on a high-fat diet. Adipose tissue distribution between visceral and subcutaneous fat depots was unaltered, with no change in adipocyte cell size. The response to both insulin and glucose dosing was normal in Lyplal1tm1a(KOMPWtsi homozygous mice, with normal fasting blood glucose concentrations. RNAseq analysis of liver, muscle and adipose tissue confirmed that Lyplal1 expression was ablated with minimal additional changes in gene expression. These results suggest that Lyplal1 is dispensable for normal mouse metabolic physiology and that despite having been maintained through evolution Lyplal1 is not an essential gene, suggesting possible functional redundancy. Further studies will be required to clarify its physiological role.

  5. Automated assessment of aortic and main pulmonary arterial diameters using model-based blood vessel segmentation for predicting chronic thromboembolic pulmonary hypertension in low-dose CT lung screening

    Science.gov (United States)

    Suzuki, Hidenobu; Kawata, Yoshiki; Niki, Noboru; Sugiura, Toshihiko; Tanabe, Nobuhiro; Kusumoto, Masahiko; Eguchi, Kenji; Kaneko, Masahiro

    2018-02-01

    Chronic thromboembolic pulmonary hypertension (CTEPH) is characterized by obstruction of the pulmonary vasculature by residual organized thrombi. A morphological abnormality inside mediastinum of CTEPH patient is enlargement of pulmonary artery. This paper presents an automated assessment of aortic and main pulmonary arterial diameters for predicting CTEPH in low-dose CT lung screening. The distinctive feature of our method is to segment aorta and main pulmonary artery using both of prior probability and vascular direction which were estimated from mediastinal vascular region using principal curvatures of four-dimensional hyper surface. The method was applied to two datasets, 64 lowdose CT scans of lung cancer screening and 19 normal-dose CT scans of CTEPH patients through the training phase with 121 low-dose CT scans. This paper demonstrates effectiveness of our method for predicting CTEPH in low-dose CT screening.

  6. SU-G-201-01: An Automated Treatment Plan Quality Assurance Program for High-Dose Rate (HDR) Brachytherapy with a VaginalCylinder Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Y; Tan, J; Jiang, S; Albuquerque, K; Jia, X [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: Plan specific quality assurance (QA) is an important step in high dose rate (HDR) brachytherapy to ensure the integrity of a treatment plan. The conventional approach is to assemble a set of plan screen-captures in a document and have an independent plan-checker to verify it. Not only is this approach cumbersome and time-consuming, using a document also limits the items that can be verified, hindering plan quality and patient safety. We have initiated efforts to develop a web-based HDR brachytherapy QA system called AutoBrachy QA, for comprehensive and efficient QA. This abstract reports a new plugin in this system for the QA of a cylinder HDR brachytherapy treatment. Methods: A cylinder plan QA module was developed using Python. It was plugged into our AutoBrachy QA system. This module extracted information from CT images and treatment plan. Image processing techniques were employed to obtain geometric parameters, e.g. cylinder diameter. A comprehensive set of eight geometrical and eight dosimetric features of the plan were validated against user specified planning parameter, such as prescription value, treatment depth and length, etc. A PDF document was generated, consisting of a summary QA sheet with all the QA results, as well as images showing plan details. Results: The cylinder QA program has been implemented in our clinic. To date, it has been used in 11 patient cases and was able to successfully perform QA tests in all of them. The QA program reduced the average plan QA time from 7 min using conventional manual approach to 0.5 min. Conclusion: Being a new module in our AutoBrachy QA system, an automated treatment plan QA module for cylinder HDR brachytherapy has been successfully developed and clinically implemented. This module improved clinical workflow and plan integrity compared to the conventional manual approach.

  7. SU-G-201-01: An Automated Treatment Plan Quality Assurance Program for High-Dose Rate (HDR) Brachytherapy with a VaginalCylinder Applicator

    International Nuclear Information System (INIS)

    Zhou, Y; Tan, J; Jiang, S; Albuquerque, K; Jia, X

    2016-01-01

    Purpose: Plan specific quality assurance (QA) is an important step in high dose rate (HDR) brachytherapy to ensure the integrity of a treatment plan. The conventional approach is to assemble a set of plan screen-captures in a document and have an independent plan-checker to verify it. Not only is this approach cumbersome and time-consuming, using a document also limits the items that can be verified, hindering plan quality and patient safety. We have initiated efforts to develop a web-based HDR brachytherapy QA system called AutoBrachy QA, for comprehensive and efficient QA. This abstract reports a new plugin in this system for the QA of a cylinder HDR brachytherapy treatment. Methods: A cylinder plan QA module was developed using Python. It was plugged into our AutoBrachy QA system. This module extracted information from CT images and treatment plan. Image processing techniques were employed to obtain geometric parameters, e.g. cylinder diameter. A comprehensive set of eight geometrical and eight dosimetric features of the plan were validated against user specified planning parameter, such as prescription value, treatment depth and length, etc. A PDF document was generated, consisting of a summary QA sheet with all the QA results, as well as images showing plan details. Results: The cylinder QA program has been implemented in our clinic. To date, it has been used in 11 patient cases and was able to successfully perform QA tests in all of them. The QA program reduced the average plan QA time from 7 min using conventional manual approach to 0.5 min. Conclusion: Being a new module in our AutoBrachy QA system, an automated treatment plan QA module for cylinder HDR brachytherapy has been successfully developed and clinically implemented. This module improved clinical workflow and plan integrity compared to the conventional manual approach.

  8. Improving Quality and Occupational Safety on Automated Casting Lines

    Directory of Open Access Journals (Sweden)

    Kukla S.

    2017-09-01

    Full Text Available The paper presents a practical example of improving quality and occupational safety on automated casting lines. Working conditions on the line of box moulding with horizontal mould split were analysed due to low degree of automation at the stage of cores or filters installation as well as spheroidizing mortar dosing. A simulation analysis was carried out, which was related to the grounds of introducing an automatic mortar dispenser to the mould. To carry out the research, a simulation model of a line in universal Arena software for modelling and simulation of manufacturing systems by Rockwell Software Inc. was created. A simulation experiment was carried out on a model in order to determine basic parameters of the working system. Organization and working conditions in other sections of the line were also analysed, paying particular attention to quality, ergonomics and occupational safety. Ergonomics analysis was carried out on manual cores installation workplace and filters installation workplace, and changes to these workplaces were suggested in order to eliminate actions being unnecessary and onerous for employees.

  9. Use of simulated patients to evaluate combined oral contraceptive dispensing practices of community pharmacists.

    Directory of Open Access Journals (Sweden)

    Paulo Roque Obreli-Neto

    Full Text Available BACKGROUND: Combined oral contraceptive (COC use is the most commonly used reversible method of birth control. The incorrect use of COCs is frequent and one of the most common causes of unintended pregnancies. Community pharmacists (CPs are in a strategic position to improve COC use because they are the last health professional to interact with patients before drug use. OBJECTIVE: To evaluate the COC dispensing practices of CPs in a developing country. METHOD: A cross-sectional study was conducted in community pharmacies of Assis and Ourinhos microregions, Brazil, between June 1, 2012, and October 30, 2012. Four simulated patients (SPs (with counseled audio recording visited community pharmacies with a prescription for Ciclo 21(® (a COC containing ethinyl estradiol 30 mcg + levonorgestrel 15 mcg. The audio recording of every SP visit was listened to independently by 3 researchers to evaluate the COC dispensing practice. The percentage of CPs who performed a screening for safe use of COCs (i.e., taking of patients' medical and family history, and measuring of blood pressure and provided counseling, as well as the quality of the screening and counseling, were evaluated. RESULTS: Of the 185 CPs contacted, 41 (22.2% agreed to participate in the study and finished the study protocol. Only 3 CPs asked the SP a question (1 question asked by each professional, and all of the questions were closed-ended, viz., "do you smoke?" (n = 2 and "what is your age?" (n = 1. None of the CPs measured the patient's blood pressure. Six CPs provided counseling when dispensing COCs (drug dosing, 5 CPs; possible adverse effects, 2 CPs, and one CP provided counseling regarding both aspects. CONCLUSION: The CPs evaluated did not dispense COC appropriately and could influence in the occurrence of negatives therapeutic outcomes such as adverse effects and treatment failure.

  10. Development of an Automatic Dispensing System for Traditional Chinese Herbs

    Directory of Open Access Journals (Sweden)

    Chi-Ying Lin

    2017-01-01

    Full Text Available The gathering of ingredients for decoctions of traditional Chinese herbs still relies on manual dispensation, due to the irregular shape of many items and inconsistencies in weights. In this study, we developed an automatic dispensing system for Chinese herbal decoctions with the aim of reducing manpower costs and the risk of mistakes. We employed machine vision in conjunction with a robot manipulator to facilitate the grasping of ingredients. The name and formulation of the decoction are input via a human-computer interface, and the dispensing of multiple medicine packets is performed automatically. An off-line least-squared curve fitting method was used to calculate the amount of material grasped by the claws and thereby improve system efficiency as well as the accuracy of individual dosages. Experiments on the dispensing of actual ingredients demonstrate the feasibility of the proposed system.

  11. Drug dispensing errors in a ward stock system

    DEFF Research Database (Denmark)

    Andersen, Stig Ejdrup

    2010-01-01

    . Multivariable analysis showed that surgical and psychiatric settings were more susceptible to involvement in dispensing errors and that polypharmacy was a risk factor. In this ward stock system, dispensing errors are relatively common, they depend on speciality and are associated with polypharmacy......The aim of this study was to determine the frequency of drug dispensing errors in a traditional ward stock system operated by nurses and to investigate the effect of potential contributing factors. This was a descriptive study conducted in a teaching hospital from January 2005 to June 2007. In five....... These results indicate that strategies to reduce dispensing errors should address polypharmacy and focus on high-risk units. This should, however, be substantiated by a future trial....

  12. Foreign private capital inflows in Nigeria's democratic dispensation ...

    African Journals Online (AJOL)

    FPCI) in Nigeria in the current democratic dispensation with a view to finding out whether the inflows have recorded significant increase since the institution of Democracy in the country. Relevant theories and empirical data were reviewed.

  13. Determinants of Dispensing Location in the TRICARE Senior Pharmacy Program

    Science.gov (United States)

    2005-01-01

    proximity to an MTF on TSRx use and on uti - lization of the different dispensing locations; and the impact of MTF formulary restrictions on use of the...Conclusions and Policy Implications Our analysis of the TSRx program, which focused on describing uti - lization patterns by dispensing location and on...manufacturers do. In the public sector, some Medicaid programs have recently hired physicians and pharmacists to visit doctors’ offices and encourage them to

  14. 46 CFR 105.90-1 - Existing commercial fishing vessels dispensing petroleum products.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Existing commercial fishing vessels dispensing petroleum... AND MISCELLANEOUS VESSELS COMMERCIAL FISHING VESSELS DISPENSING PETROLEUM PRODUCTS Existing Commercial Fishing Vessels Dispensing Petroleum Products § 105.90-1 Existing commercial fishing vessels dispensing...

  15. Steam sterilization and automatic dispensing of [{sup 18}F]fludeoxyglucose (FDG) for injection

    Energy Technology Data Exchange (ETDEWEB)

    Karwath, Pascal [Department of Nuclear Medicine, University of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany) and MC-Pharma GmbH (MCP), Bonn (Germany); Sartor, Johannes [MC-Pharma GmbH (MCP), Bonn (Germany); Gries, Wolfgang [MC-Pharma GmbH (MCP), Bonn (Germany); Wodarski, Christine [MC-Pharma GmbH (MCP), Bonn (Germany); Dittmar, Claus [MC-Pharma GmbH (MCP), Bonn (Germany); Biersack, Hans J [Department of Nuclear Medicine, University of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany); Guhlke, Stefan [Department of Nuclear Medicine, University of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany) and MC-Pharma GmbH (MCP), Bonn (Germany)

    2005-04-01

    For the purpose of implementing steam sterilization of 2-[{sup 18}F]FDG (FDG) in the final container into routine production, we have validated and established a fully automated dispensing and sterilization system, thereby considerably reducing the radiation burden to the personnel. Methods: The commercially available system combines aseptic dispensing of the product solution under a miniaturized laminar flow unit with subsequent steam sterilization, realized by heating of the product in the final containers by an autoclave included in the dispensing unit, thus incorporating current pharmaceutical manufacturing standards for the production of parental radiopharmaceuticals. The efficiency of the used sterilization cycle, the stability of FDG under the conditions of sterilization and the stability of the final product towards radiolysis was investigated with respect to various pH-formulations. Results: The system was found to be fully valid for filling of vials in a laminar flow class A (US-class 100) environment and for sterilization of FDG in the final container. The pH for sterilizing FDG solutions must be slightly acidic to avoid decomposition. A pH of 5.5 appears to be optimal and gives FDG of very high radiochemical purity ({approx}99%). In addition, radiolysis of FDG in solutions of high activity concentration was significantly lower at pH 5.5 than at neutral pH. Conclusion: Terminal sterilization enables the production of FDG in full compliance with GMP-regulations even in Class C or D (US class 10,000 or 100,000) laboratories.

  16. Steam sterilization and automatic dispensing of [18F]fludeoxyglucose (FDG) for injection

    International Nuclear Information System (INIS)

    Karwath, Pascal; Sartor, Johannes; Gries, Wolfgang; Wodarski, Christine; Dittmar, Claus; Biersack, Hans J.; Guhlke, Stefan

    2005-01-01

    For the purpose of implementing steam sterilization of 2-[ 18 F]FDG (FDG) in the final container into routine production, we have validated and established a fully automated dispensing and sterilization system, thereby considerably reducing the radiation burden to the personnel. Methods: The commercially available system combines aseptic dispensing of the product solution under a miniaturized laminar flow unit with subsequent steam sterilization, realized by heating of the product in the final containers by an autoclave included in the dispensing unit, thus incorporating current pharmaceutical manufacturing standards for the production of parental radiopharmaceuticals. The efficiency of the used sterilization cycle, the stability of FDG under the conditions of sterilization and the stability of the final product towards radiolysis was investigated with respect to various pH-formulations. Results: The system was found to be fully valid for filling of vials in a laminar flow class A (US-class 100) environment and for sterilization of FDG in the final container. The pH for sterilizing FDG solutions must be slightly acidic to avoid decomposition. A pH of 5.5 appears to be optimal and gives FDG of very high radiochemical purity (∼99%). In addition, radiolysis of FDG in solutions of high activity concentration was significantly lower at pH 5.5 than at neutral pH. Conclusion: Terminal sterilization enables the production of FDG in full compliance with GMP-regulations even in Class C or D (US class 10,000 or 100,000) laboratories

  17. Estimating the real world daily usage and cost for exenatide twice daily and liraglutide in Germany, the Netherlands, and the UK based on volumes dispensed by pharmacies

    Directory of Open Access Journals (Sweden)

    McDonell AL

    2015-01-01

    Full Text Available Amanda L McDonell,1 Urpo Kiiskinen,2 Danielle C Zammit,3 Robert W Kotchie,1 Per-Olof Thuresson,3 Claudia Nicolay,4 Thomas Haslam,1 Michiel Bruinsma,5 Anne-Jeanine Janszen-Van Oosterhout,6 Thorsten Otto41IMS Health, London, UK; 2Eli Lilly and Company, Helsinki, Finland; 3IMS Health, Basel, Switzerland; 4Eli Lilly and Company, Bad Homburg, Germany; 5IMS Health, Rotterdam, the Netherlands; 6Eli Lilly Nederland, Houten, the NetherlandsBackground: Glucagon-like peptide-1 (GLP-1 receptor agonists are indicated for improvement of glycemic control in adults with type 2 diabetes. Cost is one aspect of treatment to be considered, in addition to clinical benefits, when selecting optimal therapy for a patient. The objective of this study was to estimate the average dose usage and real world daily cost of the GLP-1 receptor agonists, exenatide twice daily and liraglutide once daily, in Germany, the Netherlands, and the UK.Methods: Administrative databases were used to source the data from longitudinal records of dispensed prescriptions. Data were extracted from the IMS Longitudinal Prescription database which captures details of prescriptions dispensed in pharmacies. Information on the dispensed quantity of each product was used to estimate average daily usage per patient. Daily dose usage was multiplied by the public price per unit to estimate daily cost.Results: The dispensed volume in Germany corresponded to a mean dispensed daily dose of 16.81 µg for exenatide twice daily and 1.37 mg for liraglutide (mean daily cost €4.02 and €4.54, respectively. In the Netherlands, average dispensed daily doses of 17.07 µg and 1.49 mg were observed for exenatide twice daily and liraglutide (mean daily cost €3.05 and €3.97, respectively. In the UK, the mean dispensed volume corresponded to a daily usage of 20.49 µg for exenatide twice daily and 1.50 mg for liraglutide (mean daily cost £2.53 and £3.28, respectively.Conclusion: Estimates of average daily

  18. [Monitoring medication errors in personalised dispensing using the Sentinel Surveillance System method].

    Science.gov (United States)

    Pérez-Cebrián, M; Font-Noguera, I; Doménech-Moral, L; Bosó-Ribelles, V; Romero-Boyero, P; Poveda-Andrés, J L

    2011-01-01

    To assess the efficacy of a new quality control strategy based on daily randomised sampling and monitoring a Sentinel Surveillance System (SSS) medication cart, in order to identify medication errors and their origin at different levels of the process. Prospective quality control study with one year follow-up. A SSS medication cart was randomly selected once a week and double-checked before dispensing medication. Medication errors were recorded before it was taken to the relevant hospital ward. Information concerning complaints after receiving medication and 24-hour monitoring were also noted. Type and origin error data were assessed by a Unit Dose Quality Control Group, which proposed relevant improvement measures. Thirty-four SSS carts were assessed, including 5130 medication lines and 9952 dispensed doses, corresponding to 753 patients. Ninety erroneous lines (1.8%) and 142 mistaken doses (1.4%) were identified at the Pharmacy Department. The most frequent error was dose duplication (38%) and its main cause inappropriate management and forgetfulness (69%). Fifty medication complaints (6.6% of patients) were mainly due to new treatment at admission (52%), and 41 (0.8% of all medication lines), did not completely match the prescription (0.6% lines) as recorded by the Pharmacy Department. Thirty-seven (4.9% of patients) medication complaints due to changes at admission and 32 matching errors (0.6% medication lines) were recorded. The main cause also was inappropriate management and forgetfulness (24%). The simultaneous recording of incidences due to complaints and new medication coincided in 33.3%. In addition, 433 (4.3%) of dispensed doses were returned to the Pharmacy Department. After the Unit Dose Quality Control Group conducted their feedback analysis, 64 improvement measures for Pharmacy Department nurses, 37 for pharmacists, and 24 for the hospital ward were introduced. The SSS programme has proven to be useful as a quality control strategy to identify Unit

  19. A network collaboration implementing technology to improve medication dispensing and administration in critical access hospitals.

    Science.gov (United States)

    Wakefield, Douglas S; Ward, Marcia M; Loes, Jean L; O'Brien, John

    2010-01-01

    We report how seven independent critical access hospitals collaborated with a rural referral hospital to standardize workflow policies and procedures while jointly implementing the same health information technologies (HITs) to enhance medication care processes. The study hospitals implemented the same electronic health record, computerized provider order entry, pharmacy information systems, automated dispensing cabinets (ADC), and barcode medication administration systems. We conducted interviews and examined project documents to explore factors underlying the successful implementation of ADC and barcode medication administration across the network hospitals. These included a shared culture of collaboration; strategic sequencing of HIT component implementation; interface among HIT components; strategic placement of ADCs; disciplined use and sharing of workflow analyses linked with HIT applications; planning for workflow efficiencies; acquisition of adequate supply of HIT-related devices; and establishing metrics to monitor HIT use and outcomes.

  20. Slow Release of Plant Volatiles Using Sol-Gel Dispensers.

    Science.gov (United States)

    Bian, L; Sun, X L; Cai, X M; Chen, Z M

    2014-12-01

    The black citrus aphid, also known as the tea aphid, (Toxoptera aurantii Boyer) attacks economically important crops, including tea (Camellia sinensis (L.) O. Kuntze). In the current study, silica sol-gel formulations were screened to find one that could carry and release C. sinensis plant volatiles to lure black citrus aphids in a greenhouse. The common plant volatile trans-2-hexen-1-al was used as a model molecule to screen for suitable sol-gel formulations. A zNose (Electronic Sensor Technology, Newbury Park, CA) transportable gas chromatograph was used to continuously monitor the volatile emissions. A sol-gel formulation containing tetramethyl orthosilicate and methyltrimethoxysilane in an 8:2 (vol:vol) ratio was selected to develop a slow-release dispenser. The half-life of trans-2-hexen-1-al in the sol-gel dispenser increased slightly with the volume of this compound in the dispenser. Ten different volatiles were tested in the sol-gel dispenser. Alcohols of 6-10 carbons had the longest half-lives (3.01-3.77 d), while esters of 6-12 carbons had the shortest (1.53-2.28 d). Release of these volatiles from the dispensers could not be detected by the zNose after 16 d (cis-3-hexenyl acetate) to 26 d (3,7-dimethylocta-1,6-dien-3-ol). In greenhouse experiments, trans-2-hexen-1-al and cis-3-hexen-1-ol released from the sol-gel dispensers attracted aphids for ≍17 d, and release of these volatiles could not be detected by the zNose after ≍24 d. The sol-gel dispensers performed adequately for the slow release of plant volatiles to trap aphids in the greenhouse. © 2014 Entomological Society of America.

  1. The K-1 Active Dispenser for Orbit Transfer

    Science.gov (United States)

    Lai, G.; Cochran, D.; Curtis, R.

    2002-01-01

    Kistler Aerospace Corporation is building the K-1, the world's first fully reusable launch vehicle. The two-stage K- 1 is designed primarily to service the market for low-earth orbit (LEO) missions, due to Kistler's need to recover both stages. For customers requiring payload delivery to high-energy orbits, Kistler can outfit the payload with a K- 1 Active Dispenser (an expendable third stage). The K-1 second stage will deploy the Active Dispenser mated with its payload into a 200 km circular LEO parking orbit. From this orbit, the Active Dispenser would use its own propulsion to place its payload into the final desired drop-off orbit or earth-escape trajectory. This approach allows Kistler to combine the low-cost launch services offered by the reusable two-stage K-1 with the versatility of a restartable, expendable upper stage. Enhanced with an Active Dispenser, the K-1 will be capable of delivering 1,500 kg to a geosynchronous transfer orbit or up to approximately 1,000 kg into a Mars rendezvous trajectory. The list price of a K-1 Active Dispenser launch is 25 million (plus the price of mission unique integration services) significantly less than the price of any launch vehicle service in the world with comparable capability.

  2. Evaluating the Impact of Drug Dispensing Systems on the Safety and Efficiency in a Singapore Outpatient Pharmacy

    Directory of Open Access Journals (Sweden)

    Peter Ong Yong Sheng

    2014-01-01

    Full Text Available Purpose: Automation of pharmacy workflow can reduce medication errors as well as improve efficiency of the medication picking, packing and labeling process. Since September 2012, two drug dispensing systems (DDS began operations in the Singapore General Hospital Specialist Outpatient Clinic Pharmacy. This study sought to evaluate the impact of the DDS on safety and efficiency in the pharmacy. Methods: The primary outcome was the rate of prevented dispensing incidents contributed by DDS or manual picking of medications defined as the number of prevented dispensing incidents per 1000 medications picked. The secondary outcome was the productivity of each full time equivalent (FTE when assigned to either the DDS or manual picking stations. Data pertaining to the primary and secondary outcomes between January and December 2013 were collected and analyzed. The rate of prevented dispensing incidents was expressed in median (interquartile range and compared using Mann-Whitney U test. Other continuous variables were expressed in mean ± standard deviation and compared using independent samples t-test. Results: An average of 59494 medications was picked every month in the pharmacy. DDS accounted for 21.1 percent while manual picking accounted for 78.9 percent of all the medications picked. The median rate of prevented dispensing incidents per month committed by manual picking (2.73 was significantly higher than the DDS (0.00. DDS had greater productivity with each FTE in the DDS having an average of 6175 picks per month which was significantly higher than each FTE in the manual picking stations which had an average of 4867 picks per month. Conclusion: Installation of DDS in an outpatient pharmacy improved safety of the pharmacy workflow by automating the medication picking, packing and labeling process and minimizing human errors. Efficiency of the medication picking, packing and labeling process was also improved by the DDS as there were continuous

  3. Do Pregnant Women Report Use of Dispensed Medications?

    DEFF Research Database (Denmark)

    Olesen, Charlotte; Søndergaard, Charlotte; Thrane, Nana

    2001-01-01

    Surveillance of drug safety in pregnancy often draws on administrative prescription registries. Noncompliance in the use of prescribed medication may be frequent among pregnant women owing to their fear of fetotoxic side effects. To estimate compliance in the use of prescription drugs dispensed...... during pregnancy, we compared prescription data from the North Jutland Prescription Database with information on drug use provided by pregnant women to the Danish National Birth Cohort (DNBC), which is a health interview survey. We used the North Jutland Prescription Database to identify all prescription...... drugs dispensed during pregnancy for the 2,041 women who were enrolled in the DNBC in the County of North Jutland, Denmark. Compliance was defined as the probability of reporting drug use in DNBC after purchasing a dispensed prescription drug. The overall compliance to drugs purchased within 120 days...

  4. Volumetric dispenser for small particles from plural sources

    International Nuclear Information System (INIS)

    Bradley, R.A.; Miller, W.H.; Sease, J.D.

    1975-01-01

    Apparatus is described for rapidly and accurately dispensing measured volumes of small particles from a supply hopper. The apparatus includes an adjustable, vertically oriented measuring tube and orifice member defining the volume to be dispensed, a ball plug valve for selectively closing the bottom end of the orifice member, and a compression valve for selectively closing the top end of the measuring tube. A supply hopper is disposed above and in gravity flow communication with the measuring tube. Properly sequenced opening and closing of the two valves provides accurate volumetric discharge through the ball plug valve. A dispensing system is described wherein several appropriately sized measuring tubes, orifice members, and associated valves are arranged to operate contemporaneously to facilitate blending of different particles

  5. Plasma processes inside dispenser hollow cathodes

    International Nuclear Information System (INIS)

    Mikellides, Ioannis G.; Katz, Ira; Goebel, Dan M.; Polk, James E.; Jameson, Kristina K.

    2006-01-01

    A two-dimensional fluid model of the plasma and neutral gas inside dispenser orificed hollow cathodes has been developed to quantify plasma processes that ultimately determine the life of the porous emitters inserted in these devices. The model self-consistently accounts for electron emission from the insert as well as for electron and ion flux losses from the plasma. Two cathodes, which are distinctively different in size and operating conditions, have been simulated numerically. It is found that the larger cathode, with outer tube diameter of 1.5 cm and orifice diameter of 0.3 cm, establishes an effective emission zone that spans approximately the full length of the emitter when operated at a discharge current of 25 A and a flow rate of 5.5 sccm. The net heating of the emitter is caused by ions that are produced by ionization of the neutral gas inside the tube and are then accelerated by the sheath along the emitter. The smaller cathode, with an outer diameter of 0.635 cm and an orifice diameter of 0.1 cm, does not exhibit the same operational characteristics. At a flow rate of 4.25 sccm and discharge current of 12 A, the smaller cathode requires 4.5 times the current density near the orifice and operates with more than 6 times the neutral particle density compared to the large cathode. As a result, the plasma particle density is almost one order of magnitude higher compared to the large cathode. The plasma density in this small cathode is high enough such that the Debye length is sufficiently small to allow 'sheath funneling' into the pores of the emitter. By accessing areas deeper into the insert material, it is postulated that the overall emission of electrons is significantly enhanced. The maximum emission current density is found to be about 1 A/mm 2 in the small cathode, which is about one order of magnitude higher than attained in the large cathode. The effective emission zone in the small cathode extends to about 15% of the emitter length only, and the

  6. Automated Inadvertent Intruder Application

    International Nuclear Information System (INIS)

    Koffman, Larry D.; Lee, Patricia L.; Cook, James R.; Wilhite, Elmer L.

    2008-01-01

    The Environmental Analysis and Performance Modeling group of Savannah River National Laboratory (SRNL) conducts performance assessments of the Savannah River Site (SRS) low-level waste facilities to meet the requirements of DOE Order 435.1. These performance assessments, which result in limits on the amounts of radiological substances that can be placed in the waste disposal facilities, consider numerous potential exposure pathways that could occur in the future. One set of exposure scenarios, known as inadvertent intruder analysis, considers the impact on hypothetical individuals who are assumed to inadvertently intrude onto the waste disposal site. Inadvertent intruder analysis considers three distinct scenarios for exposure referred to as the agriculture scenario, the resident scenario, and the post-drilling scenario. Each of these scenarios has specific exposure pathways that contribute to the overall dose for the scenario. For the inadvertent intruder analysis, the calculation of dose for the exposure pathways is a relatively straightforward algebraic calculation that utilizes dose conversion factors. Prior to 2004, these calculations were performed using an Excel spreadsheet. However, design checks of the spreadsheet calculations revealed that errors could be introduced inadvertently when copying spreadsheet formulas cell by cell and finding these errors was tedious and time consuming. This weakness led to the specification of functional requirements to create a software application that would automate the calculations for inadvertent intruder analysis using a controlled source of input parameters. This software application, named the Automated Inadvertent Intruder Application, has undergone rigorous testing of the internal calculations and meets software QA requirements. The Automated Inadvertent Intruder Application was intended to replace the previous spreadsheet analyses with an automated application that was verified to produce the same calculations and

  7. Impact of Mobile Dose-Tracking Technology on Medication Distribution at an Academic Medical Center.

    Science.gov (United States)

    Kelm, Matthew; Campbell, Udobi

    2016-05-01

    Medication dose-tracking technologies have the potential to improve efficiency and reduce costs associated with re-dispensing doses reported as missing. Data describing this technology and its impact on the medication use process are limited. The purpose of this study is to assess the impact of dose-tracking technology on pharmacy workload and drug expense at an academic, acute care medical center. Dose-tracking technology was implemented in June 2014. Pre-implementation data were collected from February to April 2014. Post-implementation data were collected from July to September 2014. The primary endpoint was the percent of re-dispensed oral syringe and compounded sterile product (CSP) doses within the pre- and post-implementation periods per 1,000 discharges. Secondary endpoints included pharmaceutical expense generated from re-dispensing doses, labor costs, and staff satisfaction with the medication distribution process. We observed an average 6% decrease in re-dispensing of oral syringe and CSP doses from pre- to post-implementation (15,440 vs 14,547 doses; p = .047). However, when values were adjusted per 1,000 discharges, this trend did not reach statistical significance (p = .074). Pharmaceutical expense generated from re-dispensing doses was significantly reduced from pre- to post-implementation ($834,830 vs $746,466 [savings of $88,364]; p = .047). We estimated that $2,563 worth of technician labor was avoided in re-dispensing missing doses. We also saw significant improvement in staff perception of technology assisting in reducing missing doses (p = .0003), as well as improvement in effectiveness of resolving or minimizing missing doses (p = .01). The use of mobile dose-tracking technology demonstrated meaningful reductions in both the number of doses re-dispensed and cost of pharmaceuticals dispensed.

  8. Home Automation

    OpenAIRE

    Ahmed, Zeeshan

    2010-01-01

    In this paper I briefly discuss the importance of home automation system. Going in to the details I briefly present a real time designed and implemented software and hardware oriented house automation research project, capable of automating house's electricity and providing a security system to detect the presence of unexpected behavior.

  9. Dispensing of non-prescribed antibiotics in Jordan

    Directory of Open Access Journals (Sweden)

    Almaaytah A

    2015-09-01

    Full Text Available Ammar Almaaytah,1 Tareq L Mukattash,2 Julia Hajaj2 1Department of Pharmaceutical Technology, 2Department of Clinical Pharmacy, Faculty of Pharmacy, Jordan University of Science and Technology, Irbid, Jordan Objective: Current regulations in Jordan state that antibiotics cannot be sold without a medical prescription. This study aimed to assess the percentage of pharmacies that dispense antibiotics without a medical prescription in the Kingdom of Jordan and identify and highlight the extent and seriousness of such practices among Jordanian pharmacies. Methods: A prospective study was performed, and five different clinical scenarios were simulated at pharmacies investigated including sore throat, otitis media, acute sinusitis, diarrhea, and urinary tract infection in childbearing-aged women. Three levels of demand were used to convince the pharmacists to sell an antibiotic. Results: A total of 202 total pharmacies in Jordan were visited in the present study. The majority of pharmacies (74.3% dispensed antibiotics without prescription with three different levels of demand. The percentage of pharmacies dispensing antibiotics without a prescription for the sore throat scenario was 97.6%, followed by urinary tract infection (83.3%, diarrhea (83%, and otitis media (68.4%. The lowest percentage of antibiotic dispensing was for the acute sinusitis simulation at 48.5%. Among the pharmacies that dispensed antibiotics, the pharmacists provided an explanation as the number of times per day the drug should be taken in 95.3% of the cases, explained the duration of treatment in 25.7%, and inquired about allergies prior to the sale of the antibiotic in only 17.3%. Only 52 pharmacies (25.7% refused to dispense any kind of antibiotics, the majority (61.5% of this refusal response came from acute sinusitis cases, while the minority (2.4% came from the sore throat cases. Conclusion: The results of this study demonstrate that antibiotics continue to be dispensed

  10. Pharmacoepidemiological Data from Drug Dispensing Charities as a Measure of Health Patterns in a Population not Assisted by the Italian National Health Service.

    Science.gov (United States)

    Bini, Silvia; Cerri, Cesare; Rigamonti, Antonello E; Bertazzi, Pietro A; Fiorini, Gianfrancesco; Cella, Silvano G

    2016-08-19

    We analysed drug dispensation by charitable organisations in a year time. Drugs were grouped according to the Anatomic Therapeutic Chemical classification and the amount dispensed was calculated with the system of the Daily Defined Dose (DDD) and expressed as DDD/1000 subjects/day. A number of 87,550 subjects were studied (13,308 Italians; 74,242 Immigrants). Though we noticed a great sesonal variability, the drugs most frequently dispensed were those for the respiratory, cardiovascular and gastrointestinal system and antibiotics, which is different from the rest of the Italian population and the immigrant population assisted by our National Health Service (NHS). We also found that chronic diseases are increasing in these subjects. We conclude that the subjects not receiving NHS assitance have, at least in part, different health patterns and requirements. This should be considered when planning tailored interventions.

  11. Pharmacoepidemiological data from drug dispensing charities as a measure of health patterns in a population not assisted by the Italian National Health Service

    Directory of Open Access Journals (Sweden)

    Silvia Bini

    2016-08-01

    Full Text Available We analysed drug dispensation by charitable organisations in a year time. Drugs were grouped according to the Anatomic Therapeutic Chemical classification and the amount dispensed was calculated with the system of the Daily Defined Dose (DDD and expressed as DDD/1000 subjects/day. A number of 87,550 subjects were studied (13,308 Italians; 74,242 Immigrants. Though we noticed a great sesonal variability, the drugs most frequently dispensed were those for the respiratory, cardiovascular and gastrointestinal system and antibiotics, which is different from the rest of the Italian population and the immigrant population assisted by our National Health Service (NHS. We also found that chronic diseases are increasing in these subjects. We conclude that the subjects not receiving NHS assitance have, at least in part, different health patterns and requirements. This should be considered when planning tailored interventions.

  12. Rates of opioid dispensing and overdose after introduction of abuse-deterrent extended-release oxycodone and withdrawal of propoxyphene.

    Science.gov (United States)

    Larochelle, Marc R; Zhang, Fang; Ross-Degnan, Dennis; Wharam, J Frank

    2015-06-01

    In the second half of 2010, abuse-deterrent extended-release oxycodone hydrochloride (OxyContin; Purdue Pharma) was introduced and propoxyphene was withdrawn from the US market. The effect of these pharmaceutical market changes on opioid dispensing and overdose rates is unknown. To evaluate the association between 2 temporally proximate changes in the opioid market and opioid dispensing and overdose rates. Claims from a large national US health insurer were analyzed, using an interrupted time series study design. Participants included an open cohort of 31.3 million commercially insured members aged 18 to 64 years between January 1, 2003, and December 31, 2012, with median follow-up of 20 months (last follow-up, December 31, 2012). Introduction of abuse-deterrent OxyContin (resistant to crushing or dissolving) on August 9, 2010, and market withdrawal of propoxyphene on November 19, 2010. Standardized opioid dispensing rates and prescription opioid and heroin overdose rates were the primary outcomes. We used segmented regression to analyze changes in outcomes from 30 quarters before to 8 quarters after the 2 interventions. Two years after the opioid market changes, total opioid dispensing decreased by 19% from the expected rate (absolute change, -32.2 mg morphine-equivalent dose per member per quarter [95% CI, -38.1 to -26.3]). By opioid subtype, the absolute change in dispensing by milligrams of morphine-equivalent dose per member per quarter at 2 years was -11.3 (95% CI, -12.4 to -10.1) for extended-release oxycodone, 3.26 (95% CI, 1.40 to 5.12) for other long-acting opioids, -8.19 (95% CI, -9.30 to -7.08) for propoxyphene, and -16.2 (95% CI, -18.8 to -13.5) for other immediate-release opioids. Two years after the market changes, the estimated overdose rate attributed to prescription opioids decreased by 20% (absolute change, -1.10 per 100,000 members per quarter [95% CI, -1.47 to -0.74]), but heroin overdose increased by 23% (absolute change, 0.26 per 100

  13. Construction of a smart medication dispenser with high degree of scalability and remote manageability.

    Science.gov (United States)

    Pak, JuGeon; Park, KeeHyun

    2012-01-01

    We propose a smart medication dispenser having a high degree of scalability and remote manageability. We construct the dispenser to have extensible hardware architecture for achieving scalability, and we install an agent program in it for achieving remote manageability. The dispenser operates as follows: when the real-time clock reaches the predetermined medication time and the user presses the dispense button at that time, the predetermined medication is dispensed from the medication dispensing tray (MDT). In the proposed dispenser, the medication for each patient is stored in an MDT. One smart medication dispenser contains mainly one MDT; however, the dispenser can be extended to include more MDTs in order to support multiple users using one dispenser. For remote management, the proposed dispenser transmits the medication status and the system configurations to the monitoring server. In the case of a specific event such as a shortage of medication, memory overload, software error, or non-adherence, the event is transmitted immediately. All these operations are performed automatically without the intervention of patients, through the agent program installed in the dispenser. Results of implementation and verification show that the proposed dispenser operates normally and performs the management operations from the medication monitoring server suitably.

  14. Construction of a Smart Medication Dispenser with High Degree of Scalability and Remote Manageability

    Directory of Open Access Journals (Sweden)

    JuGeon Pak

    2012-01-01

    Full Text Available We propose a smart medication dispenser having a high degree of scalability and remote manageability. We construct the dispenser to have extensible hardware architecture for achieving scalability, and we install an agent program in it for achieving remote manageability. The dispenser operates as follows: when the real-time clock reaches the predetermined medication time and the user presses the dispense button at that time, the predetermined medication is dispensed from the medication dispensing tray (MDT. In the proposed dispenser, the medication for each patient is stored in an MDT. One smart medication dispenser contains mainly one MDT; however, the dispenser can be extended to include more MDTs in order to support multiple users using one dispenser. For remote management, the proposed dispenser transmits the medication status and the system configurations to the monitoring server. In the case of a specific event such as a shortage of medication, memory overload, software error, or non-adherence, the event is transmitted immediately. All these operations are performed automatically without the intervention of patients, through the agent program installed in the dispenser. Results of implementation and verification show that the proposed dispenser operates normally and performs the management operations from the medication monitoring server suitably.

  15. Providers' knowledge, attitude and dispensing practices of e-pills in government dispensaries of South district in delhi, India.

    Science.gov (United States)

    Kishore, Vertika; Misro, Man M; Nandan, Deoki

    2010-01-01

    South Delhi is one of the well developed districts in the capital with best public health care facilities. Knowledge, attitude and dispensing practices of emergency contraceptive pills (E-pills) were assessed among health care providers of government dispensaries in South Delhi. A descriptive epidemiological study. Both medical and paramedical (n = 428) providers in 63 government health care facilities were interviewed between August to December 2007 using a semi-structured interview schedule. Among the different categories of the providers, medical officers were observed to be most knowledgeable about E-pills and the pharmacists were the least. The correct prescribed dose of E-pill was known only to 32% of the providers while 49% knew about its right time of intake. Misconceptions and apprehensions for promoting its use were very much prevalent even among medical officers as majority felt that open access to E-pills would increase promiscuity. The dispensing practice of providers was found positively (P pills.

  16. Drug Dosing in Patients with Renal Insufficiency in a Hospital Setting using Electronic Prescribing and Automated Reporting of Estimated Glomerular Filtration Rate

    DEFF Research Database (Denmark)

    Nielsen, Anita L.; Henriksen, Daniel Pilsgaard; Marinakis, Christianna

    2014-01-01

    In patients with impaired renal function, drug dose adjustment is often required. Non-adherence to clinical prescribing recommendations may result in severe adverse events. In previous studies, the prevalence rate of non-adherence to recommended dosing has been reported to be 19-67%. Using the cl...... decision support systems should be explored. This article is protected by copyright. All rights reserved....

  17. [Dispensing care at the dispensing counter in the conditions of a Czech pharmacy].

    Science.gov (United States)

    Macesková, B; Plevacová, H

    2005-03-01

    Evaluation of 108 cases when the pharmacist found a need to intervene into prescription verified the use of internationally employed system of classification of pharmaceutical interventions in the conditions of the Czech pharmacy of the basic type. The so-called dispensing care at the counter was provided by five participating pharmacists (out of seven working in the pharmacy) for a period of six months. The most frequently identified problems included: inappropriate use of medicaments--overdose, use at unsuitable time (28.7 %), a need to inform the patient (17.6 %), potentially ineffective therapy (12.9 %), drug interactions (7.4 %), suspected and potential undesirable effects of prescribed medicaments (7.4 %), and insufficient compliance (6.5 %). Solution of problems with medicaments was most frequently: a change in dosage (25.9 %), recommendation to consult the physician (24.1 %), and professional counselling on pharmacotherapy (23.1 %). The pharmacotherapeutic group identified as the one most frequently requiring a telephone consultation of the pharmacist and the physician was antibiotics, including antibacterial chemotherapeutic agents.

  18. Feasibility study of a biocompatible pneumatic dispensing system using mouse 3T3-J2 fibroblasts

    Science.gov (United States)

    Lee, Sangmin; Kim, Hojin; Kim, Joonwon

    2017-12-01

    This paper presents results for dispensing living cells using a pneumatic dispensing system to verify the feasibility of using this system to fabricate biomaterials. Living cells (i.e., mouse 3T3-J2 fibroblast) were dispensed with different dispensing pressures in order to evaluate the effect of dispensing process on cell viability and proliferation. Based on the results of a live-dead assay, more than 80% of cell viability has been confirmed which was reasonably similar to that in the control group. Furthermore, measurement of cell metabolic activity after dispensing confirmed that the dispensed cell proliferated at a rate comparable to that of the control group. These results demonstrate that the pneumatic dispensing system is a promising tool for fabrication of biomaterials.

  19. Rational dispensing and use of artemether-lumefantrine during ...

    African Journals Online (AJOL)

    This was a prospective-descriptive study involving visits to 200 private retail pharmacies (using a mystery shopper) and interviewing pregnant women at the municipal public hospitals in Dar es Salaam, ... There is therefore a need for continuing training of drug dispensers regarding antimalarial drugs use in pregnancy.

  20. Dispensing apparatus for use in a cued food delivery task.

    Science.gov (United States)

    Deweese, Menton M; Claiborne, Kimberly N; Ng, Jennifer; Dirba, Danika D; Stewart, Hannah L; Schembre, Susan M; Versace, Francesco

    2015-01-01

    Neurobiological models of obesity postulate that obese individuals have difficulty regulating food intake partly because they attribute excessive salience to stimuli signaling food availability. Typically, human studies that investigate the relationship between brain responses to food-related stimuli and obesity present food cues without subsequent delivery of food. However, in order to identify the brain correlates of cue reactivity, we must record brain responses to food-related cues signaling food availability. Therefore, we have developed a dispensing apparatus for use in a cued-food delivery task in which event-related potentials (ERPs) to food-related images predicting food delivery and images not predicting food delivery can be recorded. Here, we describe a method where:•The experimental apparatus dispenses an edible item (i.e., a chocolate candy) which may or may not be eaten, or a non-edible control item (e.g., a plastic bead).•Deposit boxes are available to store uneaten candies and the non-edible control items.•The dispensing mechanism is capable of recording the exact timestamp when each delivery event occurs (e.g., release from the dispenser, arrival in the receptacle, storage in the deposit box).

  1. Dispensing of vitamin products by retail pharmacies in South Africa ...

    African Journals Online (AJOL)

    Objective: The objective of this study was to analyse the dispensing patterns of vitamins (Anatomical Therapeutic Chemical (ATC) group A11) over a one-year period in a group of community pharmacies in South Africa. Design and setting: A retrospective drug utilisation study was conducted on community pharmacy ...

  2. Dispensing of drugs with and without a prescription from private ...

    African Journals Online (AJOL)

    There is little literature available on dispensing patterns and unsupervised sale of medicines from pharmacies in Tanzania. The present study assessed the patterns of drug acquisition from pharmacies by customers: whether by prescription, recommended by pharmacist, or requested by a customer without a prescription.

  3. Dispensing of vitamin products by retail pharmacies in South Africa ...

    African Journals Online (AJOL)

    Ilse Truter

    Survey) years.7 About 39% of US residents have used at least one multivitamin and ... The ATC Classification system is recommended by the. World Health ... Females in the 30 to 39-year age group were dispensed 21.95% of products ...

  4. Intra-individual diagnostic image quality and organ-specific-radiation dose comparison between spiral cCT with iterative image reconstruction and z-axis automated tube current modulation and sequential cCT

    International Nuclear Information System (INIS)

    Wenz, Holger; Maros, Máté E.; Meyer, Mathias; Gawlitza, Joshua; Förster, Alex; Haubenreisser, Holger; Kurth, Stefan; Schoenberg, Stefan O.; Groden, Christoph; Henzler, Thomas

    2016-01-01

    •Superiority of spiral versus sequential cCT in image quality and organ-specific-radiation dose.•Spiral cCT: lower organ-specific-radiation-dose in eye lense compared to tilted sequential cCT.•State-of-the-art IR spiral cCT techniques has significant advantages over sequential cCT techniques. Superiority of spiral versus sequential cCT in image quality and organ-specific-radiation dose. Spiral cCT: lower organ-specific-radiation-dose in eye lense compared to tilted sequential cCT. State-of-the-art IR spiral cCT techniques has significant advantages over sequential cCT techniques. To prospectively evaluate image quality and organ-specific-radiation dose of spiral cranial CT (cCT) combined with automated tube current modulation (ATCM) and iterative image reconstruction (IR) in comparison to sequential tilted cCT reconstructed with filtered back projection (FBP) without ATCM. 31 patients with a previous performed tilted non-contrast enhanced sequential cCT aquisition on a 4-slice CT system with only FBP reconstruction and no ATCM were prospectively enrolled in this study for a clinical indicated cCT scan. All spiral cCT examinations were performed on a 3rd generation dual-source CT system using ATCM in z-axis direction. Images were reconstructed using both, FBP and IR (level 1–5). A Monte-Carlo-simulation-based analysis was used to compare organ-specific-radiation dose. Subjective image quality for various anatomic structures was evaluated using a 4-point Likert-scale and objective image quality was evaluated by comparing signal-to-noise ratios (SNR). Spiral cCT led to a significantly lower (p < 0.05) organ-specific-radiation dose in all targets including eye lense. Subjective image quality of spiral cCT datasets with an IR reconstruction level 5 was rated significantly higher compared to the sequential cCT acquisitions (p < 0.0001). Consecutive mean SNR was significantly higher in all spiral datasets (FBP, IR 1–5) when compared to sequential cCT with a mean

  5. 46 CFR 105.05-1 - Commercial fishing vessels dispensing petroleum products.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Commercial fishing vessels dispensing petroleum products... MISCELLANEOUS VESSELS COMMERCIAL FISHING VESSELS DISPENSING PETROLEUM PRODUCTS Application § 105.05-1 Commercial fishing vessels dispensing petroleum products. (a) The provisions of this part, with the exception of...

  6. 46 CFR 105.45-1 - Loading or dispensing petroleum products.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Loading or dispensing petroleum products. 105.45-1... VESSELS COMMERCIAL FISHING VESSELS DISPENSING PETROLEUM PRODUCTS Special Operating Requirements § 105.45-1 Loading or dispensing petroleum products. (a) A commercial fishing vessel must have aboard a letter of...

  7. Pharmacy Professionals' Dispensing Practice, Knowledge, and Attitude towards Emergency Contraceptives in Gondar Town, Northwestern Ethiopia: A Cross-Sectional Study.

    Science.gov (United States)

    Belachew, Sewunet Admasu; Yimenu, Dawit Kumilachew; Gebresillassie, Begashaw Melaku

    2017-01-01

    Pharmacy professionals, as the most available members of medical team, have an important role in educating patients about the effective and appropriate use of contraceptives. The purpose of this study was to assess pharmacy professionals' dispensing practice, knowledge, and attitude towards emergency contraceptives use in Gondar town, northwestern Ethiopia. An institution based cross-sectional study was employed from May 14 to June 14, 2016, on 60 pharmacy professionals, who have been working in 8 randomly selected pharmacies and 6 drug stores. The collected data was entered to and analyzed using Statistical Packages for Social Sciences (SPSS) version 20. More than half 33 (55.0%) of the participants were druggist with 5-9 years of experience. About 56 (93.3%) of the participants knew about the dosing schedule (when and how much to take) and side effects of emergency contraceptives. More than two-thirds of the participants (39, 65%) agreed that the existence of emergency contraceptives is a positive thing and considered their use is ethical (42, 63.3%). The majority of participants (51, 85%) also reported that they counsel all women when dispensing emergency contraceptive pills (ECPs). This study revealed that knowledge, attitude, and dispensing practice of emergency contraceptives are very good even though there were variations with respect to different factors. Findings suggested that additional training and proper counseling technique on emergency contraceptives will improve the service delivery.

  8. Pharmacy Professionals’ Dispensing Practice, Knowledge, and Attitude towards Emergency Contraceptives in Gondar Town, Northwestern Ethiopia: A Cross-Sectional Study

    Directory of Open Access Journals (Sweden)

    Sewunet Admasu Belachew

    2017-01-01

    Full Text Available Background. Pharmacy professionals, as the most available members of medical team, have an important role in educating patients about the effective and appropriate use of contraceptives. The purpose of this study was to assess pharmacy professionals’ dispensing practice, knowledge, and attitude towards emergency contraceptives use in Gondar town, northwestern Ethiopia. Methods. An institution based cross-sectional study was employed from May 14 to June 14, 2016, on 60 pharmacy professionals, who have been working in 8 randomly selected pharmacies and 6 drug stores. The collected data was entered to and analyzed using Statistical Packages for Social Sciences (SPSS version 20. Result. More than half 33 (55.0% of the participants were druggist with 5–9 years of experience. About 56 (93.3% of the participants knew about the dosing schedule (when and how much to take and side effects of emergency contraceptives. More than two-thirds of the participants (39, 65% agreed that the existence of emergency contraceptives is a positive thing and considered their use is ethical (42, 63.3%. The majority of participants (51, 85% also reported that they counsel all women when dispensing emergency contraceptive pills (ECPs. Conclusion. This study revealed that knowledge, attitude, and dispensing practice of emergency contraceptives are very good even though there were variations with respect to different factors. Findings suggested that additional training and proper counseling technique on emergency contraceptives will improve the service delivery.

  9. "This is not a drill": Activation of a student-led influenza vaccination point of dispensing.

    Science.gov (United States)

    Adams, Lavonne M; Canclini, Sharon; Tillman, Kelle

    2018-04-13

    To describe activation of a Point of dispensing (POD) in response to an influenza outbreak, highlighting the use of a student-led model. Faculty, staff, and students of Harris College of Nursing and Health Sciences, Texas Christian University (TCU), as well as those located in its primary building. In response to an August 2017 influenza outbreak, a vaccination clinic was conducted for a target population through POD activation. The larger campus community was served through provision of additional doses by the Texas Christian University Health Center and the annual October student-led vaccination clinic. Eleven additional cases were diagnosed after vaccinations began. One hundred percent of the targeted population was vaccinated (n = 824), with an additional 127 participants vaccinated (others working in the building where POD held also vaccinated). This was the first time POD activation had occurred on campus in response to an outbreak.

  10. Fabrication and Measurement of Low Work Function Cesiated Dispenser Photocathodes

    CERN Document Server

    Moody, Nathan A; Jensen, Kevin

    2005-01-01

    Photoinjector performance is a limiting factor in the continued development of high powered FELs and electron beam-based accelerators. Presently available photocathodes are plagued with limited efficiency and short lifetime in an RF-gun environment, due to contamination or evaporation of a photosensitive surface layer. An ideal photocathode should have high efficiency at long wavelengths, long lifetime in practical vacuum environments, and prompt emission. Cathodes with high efficiency typically have limited lifetime, and vice versa, and the needs of the photocathode are generally at odds with those of the drive laser. A potential solution is the low work function dispenser cathode, where lifetime issues are overcome by periodic in situ regeneration that restores the photosensitive surface layer, analogous to those used in the microwave power tube industry. This work reports on the fabrication techniques and performance of cesiated metal photocathodes and cesiated dispenser cathodes, with a focus on understan...

  11. All dispenser printed flexible 3D structured thermoelectric generators

    Science.gov (United States)

    Cao, Z.; Shi, J. J.; Torah, R. N.; Tudor, M. J.; Beeby, S. P.

    2015-12-01

    This work presents a vertically fabricated 3D thermoelectric generator (TEG) by dispenser printing on flexible polyimide substrate. This direct-write technology only involves printing of electrodes, thermoelectric active materials and structure material, which needs no masks to transfer the patterns onto the substrate. The dimension for single thermoelectric element is 2 mm × 2 mm × 0.5 mm while the distance between adjacent cubes is 1.2 mm. The polymer structure layer was used to support the electrodes which are printed to connect the top ends of the thermoelectric material and ensure the flexibility as well. The advantages and the limitations of the dispenser printed 3D TEGs will also be evaluated in this paper. The proposed method is potential to be a low-cost and scalable fabrication solution for TEGs.

  12. Automated treatment planning for a dedicated multi-source intra-cranial radiosurgery treatment unit accounting for overlapping structures and dose homogeneity

    Energy Technology Data Exchange (ETDEWEB)

    Ghobadi, Kimia; Ghaffari, Hamid R. [Department of Mechanical and Industrial Engineering, University of Toronto, Ontario M5S 3G8 (Canada); Aleman, Dionne M. [Department of Mechanical and Industrial Engineering, University of Toronto, Ontario M5S 3G8 (Canada); Institute of Health Policy, Management and Evaluation, University of Toronto, Ontario M5T 3M6 (Canada); Techna Institute, University Health Network, Ontario M5G 1P5 (Canada); Jaffray, David A. [Radiation Medicine Program, Princess Margaret Hospital, University Health Network, Ontario M5T 2M9 (Canada); Department of Radiation Oncology, University of Toronto, Ontario M5S 3E2 (Canada); Department of Medical Biophysics, University of Toronto, Ontario M5G 2M9 (Canada); Institute of Biomaterial and Biomedical Engineering, University of Toronto, Ontario M5S 2J7 (Canada); Techna Institute, University Health Network, Ontario M5G 1P5 (Canada); Ontario Cancer Institute, Ontario M5G 0A3 (Canada); Ruschin, Mark [Department of Medical Physics, Odette Cancer Centre, Toronto, Ontario M4N 3M5 (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario M5S 3E2 (Canada)

    2013-09-15

    Purpose: The purpose of this work is to advance the two-step approach for Gamma Knife{sup ®} Perfexion™ (PFX) optimization to account for dose homogeneity and overlap between the planning target volume (PTV) and organs-at-risk (OARs).Methods: In the first step, a geometry-based algorithm is used to quickly select isocentre locations while explicitly accounting for PTV-OARs overlaps. In this approach, the PTV is divided into subvolumes based on the PTV-OARs overlaps and the distance of voxels to the overlaps. Only a few isocentres are selected in the overlap volume, and a higher number of isocentres are carefully selected among voxels that are immediately close to the overlap volume. In the second step, a convex optimization is solved to find the optimal combination of collimator sizes and their radiation duration for each isocentre location.Results: This two-step approach is tested on seven clinical cases (comprising 11 targets) for which the authors assess coverage, OARs dose, and homogeneity index and relate these parameters to the overlap fraction for each case. In terms of coverage, the mean V{sub 99} for the gross target volume (GTV) was 99.8% while the V{sub 95} for the PTV averaged at 94.6%, thus satisfying the clinical objectives of 99% for GTV and 95% for PTV, respectively. The mean relative dose to the brainstem was 87.7% of the prescription dose (with maximum 108%), while on average, 11.3% of the PTV overlapped with the brainstem. The mean beam-on time per fraction per dose was 8.6 min with calibration dose rate of 3.5 Gy/min, and the computational time averaged at 205 min. Compared with previous work involving single-fraction radiosurgery, the resulting plans were more homogeneous with average homogeneity index of 1.18 compared to 1.47.Conclusions: PFX treatment plans with homogeneous dose distribution can be achieved by inverse planning using geometric isocentre selection and mathematical modeling and optimization techniques. The quality of the

  13. Impact of Robotic Dispensing Machines in German Pharmacies on ...

    African Journals Online (AJOL)

    As a result of using a robotic dispensing machine, personnel costs were reduced by an average of 4.6% during the first 12 months after start-up. Over-the-counter sales increased in the same period by an average of 6.8%. Despite average initial costs of 118,000 euros, total costs within the first 12 months fell in 50% of cases ...

  14. [Design and piloting of a structured service medication dispensing process].

    Science.gov (United States)

    Abaurre, Raquel; García-Delgado, Pilar; Maurandi, M Dolores; Arrebola, Cristóbal; Gastelurrutia, Miguel Ángel; Martínez-Martínez, Fernando

    2015-01-01

    The aim of this article is to design and pilot a protocol for the dispensing of medications service. Using the requirements proposed in the Ministry of Health Pharmaceutical Care Consensus, a literature search was made applying qualitative consensus techniques. An observational, cross-sectional study was conducted from March to June 2009. A total of 53 community pharmacies from 24 Spanish counties. Patients who requested one or more particular medications with or without medical prescription for their own use or for someone in their care. The personalised medication information (IPM), the problems associated with the medications (PRM), and the negative results associated with the medication (RNM), detected by the pharmacist each time medication was dispensed, as well as the perception of the pharmacist on the operability of the protocol were recorded. A total of 870 medications were dispensed, with 423 (48.6%) cases of lack of personalised medication information (IPM) being detected. PRM were detected in 10.11% of the dispensed medications, as well as 68 (7.81%) suspected RNM: safety (n = 35; 51.5%), effectiveness (n = 29; 42.6%) and necessity (n = 4; 5.8%). Almost two-thirds (65.21%) of the pharmacists said that the protocol is in operation. The designed protocol helped to detect deficiencies in the information to the patients about their medications, as well as the PRM and RNM, and is shown to be tool that is easy to use and apply. Copyright © 2013 Elsevier España, S.L.U. All rights reserved.

  15. Dispensing with conscience: a legal and ethical assessment.

    Science.gov (United States)

    Wernow, Jerome R; Grant, Donald G

    2008-11-01

    For over 30 years, pharmacists have exercised the right to dispense medications in accordance with moral convictions based upon a Judeo-Christian ethic. What many of these practitioners see as an apparent shift away from this time-honored ethic has resulted in a challenge to this right. To review and analyze pharmacy practice standards, legal proceedings, and ethical principles behind conflicts of conscientious objection in dispensing drugs used for emergency contraception. We first searched the terms conscience and clause and Plan B and contraception and abortion using Google, Yahoo, and Microsoft Networks (2006-September 26, 2008). Second, we used Medscape to search professional pharmacy and other medical journals, restricting our terms to conscience, Plan B, contraceptives, and abortifacients. Finally, we employed Loislaw, an online legal archiving service, and did a global search on the phrase conscience clause to determine the status of the legal discussion. To date, conflicts in conscientious objection have arisen when a pharmacist believes that dispensing an oral contraceptive violates his or her moral understanding for the promotion of human life. Up to this time, cases in pharmacy have involved only practitioners from orthodox Christian faith communities, primarily devout Roman Catholics. A pharmacist's right to refuse the dispensing of abortifacients for birth control according to moral conscience over against a woman's right to reproductive birth control has created a conflict that has yet to be reconciled by licensing agents, professional standards, or courts of law. Our analysis of prominent conflicts suggests that the underlying worldviews between factions make compromise improbable. Risks and liabilities are dependent upon compliance with evolving state laws, specific disclosure of a pharmacist's moral objections, and professionalism in the handling of volatile situations. Objecting pharmacists and their employers should have clear policies and

  16. Community pharmacists’ attitudes and knowledge on dispensing drugs.

    Directory of Open Access Journals (Sweden)

    Baldon JP

    2006-03-01

    Full Text Available The present study aimed to assess knowledge and attitudes of the pharmacists on dispensing drugs to pregnant women. Methods: Cross-sectional study in 150 community pharmacies randomly selected in Curitiba (Brazil. A closed end questionnaire with 25 questions were used, including dispensing scenarios containing risk types A, B, D or X and questions on pharmacist interaction with pregnant women, physicians, and information sources availability. Results: Pharmacists performed appropriately in 53% of the encounters. Lower success were associated to prednison and captopril (24.8% in both, end cases producing more doubts were captopril (31.7% and simvastatin (30.7%. Most of the pharmacists state have advised drugs to pregnant women or contact to the physician to discuss about a prescription related with this issue. A Majority (64.4% did not feel able to understand FDA risk classification and did not have trustable information sources in pharmacy. Conclusions: Pharmacists dispensing drugs in Curitiba are not able to interpret information on the use of drugs in pregnant women, and they don have reliable information sources on the use of dugs in pregnancy. However, they advice and counsel drugs to pregnant women and discuss with physicians therapeutic strategies.

  17. Dosing method of physical activity in aerobics classes for students

    Directory of Open Access Journals (Sweden)

    Yu.I. Beliak

    2014-10-01

    Full Text Available Purpose : reasons for the method of dosing of physical activity in aerobics classes for students. The basis of the method is the evaluation of the metabolic cost of funds used in them. Material : experiment involved the assessment of the pulse response of students to load complexes classical and step aerobics (n = 47, age 20-23 years. In complexes used various factors regulating the intensity: perform combinations of basic steps, involvement of movements with his hands, holding in hands dumbbells weighing 1kg increase in the rate of musical accompaniment, varying heights step platform. Results . on the basis of the relationship between heart rate and oxygen consumption was determined by the energy cost of each admission control load intensity. This indicator has been used to justify the intensity and duration of multiplicity aerobics. Figure correspond to the level of physical condition and motor activity deficits students. Conclusions : the estimated component of this method of dosing load makes it convenient for use in automated computer programs. Also it can be easily modified to dispense load other types of recreational fitness.

  18. AUTOMATED INADVERTENT INTRUDER APPLICATION

    International Nuclear Information System (INIS)

    Koffman, L; Patricia Lee, P; Jim Cook, J; Elmer Wilhite, E

    2007-01-01

    The Environmental Analysis and Performance Modeling group of Savannah River National Laboratory (SRNL) conducts performance assessments of the Savannah River Site (SRS) low-level waste facilities to meet the requirements of DOE Order 435.1. These performance assessments, which result in limits on the amounts of radiological substances that can be placed in the waste disposal facilities, consider numerous potential exposure pathways that could occur in the future. One set of exposure scenarios, known as inadvertent intruder analysis, considers the impact on hypothetical individuals who are assumed to inadvertently intrude onto the waste disposal site. Inadvertent intruder analysis considers three distinct scenarios for exposure referred to as the agriculture scenario, the resident scenario, and the post-drilling scenario. Each of these scenarios has specific exposure pathways that contribute to the overall dose for the scenario. For the inadvertent intruder analysis, the calculation of dose for the exposure pathways is a relatively straightforward algebraic calculation that utilizes dose conversion factors. Prior to 2004, these calculations were performed using an Excel spreadsheet. However, design checks of the spreadsheet calculations revealed that errors could be introduced inadvertently when copying spreadsheet formulas cell by cell and finding these errors was tedious and time consuming. This weakness led to the specification of functional requirements to create a software application that would automate the calculations for inadvertent intruder analysis using a controlled source of input parameters. This software application, named the Automated Inadvertent Intruder Application, has undergone rigorous testing of the internal calculations and meets software QA requirements. The Automated Inadvertent Intruder Application was intended to replace the previous spreadsheet analyses with an automated application that was verified to produce the same calculations and

  19. Process automation

    International Nuclear Information System (INIS)

    Moser, D.R.

    1986-01-01

    Process automation technology has been pursued in the chemical processing industries and to a very limited extent in nuclear fuel reprocessing. Its effective use has been restricted in the past by the lack of diverse and reliable process instrumentation and the unavailability of sophisticated software designed for process control. The Integrated Equipment Test (IET) facility was developed by the Consolidated Fuel Reprocessing Program (CFRP) in part to demonstrate new concepts for control of advanced nuclear fuel reprocessing plants. A demonstration of fuel reprocessing equipment automation using advanced instrumentation and a modern, microprocessor-based control system is nearing completion in the facility. This facility provides for the synergistic testing of all chemical process features of a prototypical fuel reprocessing plant that can be attained with unirradiated uranium-bearing feed materials. The unique equipment and mission of the IET facility make it an ideal test bed for automation studies. This effort will provide for the demonstration of the plant automation concept and for the development of techniques for similar applications in a full-scale plant. A set of preliminary recommendations for implementing process automation has been compiled. Some of these concepts are not generally recognized or accepted. The automation work now under way in the IET facility should be useful to others in helping avoid costly mistakes because of the underutilization or misapplication of process automation. 6 figs

  20. Semi-automated lab-on-a-chip for dispensing GA-68 radiotracers

    Energy Technology Data Exchange (ETDEWEB)

    Weinberg, Irving [Weinberg Medical Physics LLC, Bethesda, MD (United States)

    2014-03-12

    We solved a technical problem that is hindering American progress in molecular medicine, and restricting US citizens from receiving optimal diagnostic care. Specifically, the project deals with a mother/daughter generator of positron-emitting radiotracers (Ge-68/Ga-68). These generator systems are approved in Europe but cannot be used in the USA, because of safety issues related to possible breakthrough of long-lived Ge-68 (mother) atoms. Europeans have demonstrated abilities of Ga-68-labeled radiotracers to image cancer foci with high sensitivity and specificity, and to use such methods to effectively plan therapy.The USA Food and Drug Administration (FDA) and Nuclear Regulatory Commission (NRC) have taken the position that every patient administration of Ga-68 should be preceded by an assay demonstrated that Ge-68 breakthrough is within acceptable limits. Breakthrough of parent elements is a sensitive subject at the FDA, as evidenced by the recent recall of Rb-82 generators due to inadvertent administrations of Sr-82. Commercially, there is no acceptable rapid method for assaying breakthrough of Ge-68 prior to each human administration. The gamma emissions of daughter Ga-68 have higher energies than the parent Ge-68, so that the shielding assays typically employed for Mo-99/Tc-99m generators cannot be applied to Ga-68 generators. The half-life of Ga-68 is 68 minutes, so that the standard 10-half-life delay (used to assess breakthrough in Sr-82/Rb-82 generators) cannot be applied to Ga-68 generators. As a result of the aforementioned regulatory requirements, Ga-68 generators are sold in the USA for animal use only.The American clinical community’s inability to utilize Ga-68 generators impairs abilities to treat patients domestically, and puts the USA at a disadvantage in developing exportable products. The proposed DOE project aimed to take advantage of recent technological advances developed for lab-on-a-chip (LOC) applications. Based on our experiences constructing such devices, the proposed microfluidics-based approach could provide cost-effective validation of breakthrough compliance in minutes.

  1. Distribution automation

    International Nuclear Information System (INIS)

    Gruenemeyer, D.

    1991-01-01

    This paper reports on a Distribution Automation (DA) System enhances the efficiency and productivity of a utility. It also provides intangible benefits such as improved public image and market advantages. A utility should evaluate the benefits and costs of such a system before committing funds. The expenditure for distribution automation is economical when justified by the deferral of a capacity increase, a decrease in peak power demand, or a reduction in O and M requirements

  2. Effect of automated tube voltage selection, integrated circuit detector and advanced iterative reconstruction on radiation dose and image quality of 3rd generation dual-source aortic CT angiography: An intra-individual comparison.

    Science.gov (United States)

    Mangold, Stefanie; De Cecco, Carlo N; Wichmann, Julian L; Canstein, Christian; Varga-Szemes, Akos; Caruso, Damiano; Fuller, Stephen R; Bamberg, Fabian; Nikolaou, Konstantin; Schoepf, U Joseph

    2016-05-01

    To compare, on an intra-individual basis, the effect of automated tube voltage selection (ATVS), integrated circuit detector and advanced iterative reconstruction on radiation dose and image quality of aortic CTA studies using 2nd and 3rd generation dual-source CT (DSCT). We retrospectively evaluated 32 patients who had undergone CTA of the entire aorta with both 2nd generation DSCT at 120kV using filtered back projection (FBP) (protocol 1) and 3rd generation DSCT using ATVS, an integrated circuit detector and advanced iterative reconstruction (protocol 2). Contrast-to-noise ratio (CNR) was calculated. Image quality was subjectively evaluated using a five-point scale. Radiation dose parameters were recorded. All studies were considered of diagnostic image quality. CNR was significantly higher with protocol 2 (15.0±5.2 vs 11.0±4.2; p<.0001). Subjective image quality analysis revealed no significant differences for evaluation of attenuation (p=0.08501) but image noise was rated significantly lower with protocol 2 (p=0.0005). Mean tube voltage and effective dose were 94.7±14.1kV and 6.7±3.9mSv with protocol 2; 120±0kV and 11.5±5.2mSv with protocol 1 (p<0.0001, respectively). Aortic CTA performed with 3rd generation DSCT, ATVS, integrated circuit detector, and advanced iterative reconstruction allow a substantial reduction of radiation exposure while improving image quality in comparison to 120kV imaging with FBP. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. Maintaining Microclimates during Nanoliter Chemical Dispensations Using Custom-Designed Source Plate Lids.

    Science.gov (United States)

    Foley, Bryan J; Drozd, Ashley M; Bollard, Mary T; Laspina, Denise; Podobedov, Nikita; Zeniou, Nicholas; Rao, Anjali S; Andi, Babak; Jackimowicz, Rick; Sweet, Robert M; McSweeney, Sean; Soares, Alexei S

    2016-02-01

    A method is described for using custom snap-on lids to protect chemicals in microtiter plates from evaporation and contamination. The lids contain apertures (diameter 1.5, 1.0, or 0.5 mm) through which the chemical building blocks can be transferred. The lid with 0.5 mm apertures was tested using a noncontact acoustic liquid handler; the 1.0 and 1.5 mm lids were tested using two tip-based liquid handlers. All of the lids reduced the rate at which solvents evaporated to room air, and greatly reduced the rate of contamination by water and oxygen from room air. In steady-state measurements, the lids reduced the rate of evaporation of methanol, 1-hexene, and water by 33% to 248%. In cycled experiments, the contamination of aqueous solvent with oxygen was reduced below detectability and the rate at which DMSO engorged atmospheric water was reduced by 81%. Our results demonstrate that the lids preserve the integrity of air-sensitive reagents during the time needed for different types of liquid handlers to perform dispensations. Controlling degradation and evaporation of chemical building blocks exposed to the atmosphere is increasingly useful as the reagent volume is reduced by advances in liquid handling technology, such as acoustic droplet ejection. © 2015 Society for Laboratory Automation and Screening.

  4. A new protocol for evaluating the efficacy of some dispensing systems of a packaging in the microbial protection of water-based preservative-free cosmetic products.

    Science.gov (United States)

    Devlieghere, F; De Loy-Hendrickx, A; Rademaker, M; Pipelers, P; Crozier, A; De Baets, B; Joly, L; Keromen, S

    2015-12-01

    A new protocol is described for assessing the efficacy of the dispenser of some packaging systems (PSs) of preservative-free cosmetic products in protecting both their contained formula and their delivered doses. Practically, aiming at mimicking contacts with a non-sterile skin or fingers, the dispensing system is put into contact with a pre-contaminated fabric by a standardized colonization of P. aeruginosa. When applied to three different types of packaging, results show clear differences in both criteria between these conditioning articles, that is variable efficacies in protecting the contained product and the delivered doses, knowing that the first aspect is of paramount importance. The proposed protocol is proved being able to discriminate between different PSs and provides information on strong and weak features of certain types dispensing technologies prone to efficiently decrease either the dose contamination or to prevent contamination in reaching the contained product. Therefore, the proposed protocol can contribute to an objective selection of a PS for protecting a cosmetic care product with a low content of preservative or preservative free. © 2015 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  5. A frequency conversion mode for dispenser in the service station based on flow rate signal

    International Nuclear Information System (INIS)

    Liu, Y J; Tang, D; Huang, J B; Liu, J; Jia, P F

    2012-01-01

    Dispenser is an integrated fuel transport and measurement system at the service station. In this paper, we developed a frequency conversion mode for the dispenser, based on the flow rate signal which is obtained from the converter measuring flow capacity. After introducing the frequency conversion mode to dispenser, we obtained that pump rotates at a high speed when fuelled with high flow rate, and it rotates at a low speed when fuelled with low flow rate. This makes the fuel dispenser more energy-efficient and controllable. We also did some valve optimizations on the dispenser and developed a new control mode for preset refuelling based on the frequency conversion mode, Experimental and theoretical studies have shown that the new dispenser not only can meet the national standards, but also performs better than the ordinary one especially in preset refuelling.

  6. A Curriculum For Dispensing Optician A Case Study In Vietnam

    Directory of Open Access Journals (Sweden)

    Duong Dieu MD

    2015-08-01

    Full Text Available Until 2011 there had been no full-time training course for dispensing optician diploma in Vietnam. Most of the practicing opticians with no qualification and formal training have learnt their skills through apprentice. In response to the demand of the industry Nguyen Tat Thanh University Vietnam has teamed up with Bradford College United Kingdom to develop a curriculum for a of formal 2-year full-time training for dispensing optician. The curriculum is applied for 4 semesters and graduate gets called Intermediate Professional Diploma level included 4 semesters. In VN after high school students can obtain different many levels of study such as Intermediate Professional Diploma College Bachelor Master and PhD. The 1st semester is basis of Intermediate Professional Diploma level. The 2nd semester is the study of refractive error and primary care each for 4 weeks 100 hours in theory and primary eye care 4 weeks for theory 100 hours. Also in this semester the learners have practiced clinical rotation at the Ophthalmic Hospital Ophthalmic Service in General Hospital for 10 weeks. The 3rd semester is specialized of dispensing Optician included Lenses frame contact lenses and laboratory for optician. In the 4th semester the training concentrates in the management of the eyeglasses shop and practicing in making spectacles for customers are in the 4th semester. The 1st intake of the course was opened started in 2011 and had 30 students graduated in 2013. This paper describes the experience of developing the curriculum in the context of a developing country where the industry is still under regulated and less developed. The first program optician that privileged on primary eye care will be satisfied for community WHO 2020 1 optometrist for 50.000 people and 10 ophthalmologists for 1.000.000 people. Some characteristics of first course students have been noted. The result of this curriculum will be evaluated in the coming time.

  7. Automation of the monitoring in real time of the absorbed dose rate in air due to the environmental gamma radiation in Cuba

    International Nuclear Information System (INIS)

    Dominguez L, O.; Capote F, E.; Carrazana G, J.A.; Manzano de Armas, J.F.; Alonso A, D.; Prendes A, M.; Zerquera, J.T.; Caveda R, C.A.; Kalberg, O.; Fabelo B, O.; Montalvan E, A.; Cartas A, H.; Leyva F, J.C.

    2006-01-01

    The Center of Protection and Hygiene of the Radiations (CPHR) like center rector of the National Net of Environmental Radiological Surveillance (RNVRA), it has strengthened their detection capacity and of answer before a situation of radiological emergency. The measurements of the absorbed dose rate in air due to the environmental gamma radiation in the main stations of the Net are obtained in real time and the CPHR receives the data coming from these posts at one time relatively short. To improve the operability of the RNVRA it was necessary to complete the facilities of existent monitoring using 4 automatic measurement stations with probes of gamma detection, implementing in this way a measurement system on real time. On the other hand the software were developed: GenironProbeFech, to obtain the data of the probes, DataMail for the shipment of the same ones by electronic mail and GammaRed that receives and processes the data in the rector center. (Author)

  8. Automated diagnostic kiosk for diagnosing diseases

    Science.gov (United States)

    Regan, John Frederick; Birch, James Michael

    2014-02-11

    An automated and autonomous diagnostic apparatus that is capable of dispensing collection vials and collections kits to users interesting in collecting a biological sample and submitting their collected sample contained within a collection vial into the apparatus for automated diagnostic services. The user communicates with the apparatus through a touch-screen monitor. A user is able to enter personnel information into the apparatus including medical history, insurance information, co-payment, and answer a series of questions regarding their illness, which is used to determine the assay most likely to yield a positive result. Remotely-located physicians can communicate with users of the apparatus using video tele-medicine and request specific assays to be performed. The apparatus archives submitted samples for additional testing. Users may receive their assay results electronically. Users may allow the uploading of their diagnoses into a central databank for disease surveillance purposes.

  9. Large area dispenser cathode applied to high current linac

    International Nuclear Information System (INIS)

    Yang Anmin; China Academy of Engineering Physics, Mianyang; Wu Dengxue; Liu Chenjun; Xia Liansheng; Wang Wendou; Zhang Kaizhi

    2005-01-01

    The paper introduced a dispenser cathode (411 M) which was 55 mm in diameter. A 200 kV long pulsed power generator with 2 μs flattop based on Marx-PEN and system with heat and voltage insulation were built. A 52 A space charge limited current was gained, when the temperature was 1165 degree C and the filament current was 18 A on the cathode and the voltage of the pulse was 75 kV at the cathode test stand. Experimental results show that the current values are consistent with the numerical simulation. The experiment reveals that the deflated gas will influence the cathode emission ability. (authors)

  10. Guide to Permitting Hydrogen Motor Fuel Dispensing Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Rivkin, Carl [National Renewable Energy Lab. (NREL), Golden, CO (United States); Buttner, William [National Renewable Energy Lab. (NREL), Golden, CO (United States); Burgess, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-03-28

    The purpose of this guide is to assist project developers, permitting officials, code enforcement officials, and other parties involved in developing permit applications and approving the implementation of hydrogen motor fuel dispensing facilities. The guide facilitates the identification of the elements to be addressed in the permitting of a project as it progresses through the approval process; the specific requirements associated with those elements; and the applicable (or potentially applicable) codes and standards by which to determine whether the specific requirements have been met. The guide attempts to identify all applicable codes and standards relevant to the permitting requirements.

  11. Dicer is dispensable for asymmetric RISC loading in mammals.

    Science.gov (United States)

    Betancur, Juan G; Tomari, Yukihide

    2012-01-01

    In flies, asymmetric loading of small RNA duplexes into Argonaute2-containing RNA-induced silencing complex (Ago2-RISC) requires Dicer-2/R2D2 heterodimer, which acts as a protein sensor for the thermodynamic stabilities of the ends of small RNA duplexes. However, the mechanism of small RNA asymmetry sensing in mammalian RISC assembly remains obscure. Here, we quantitatively examined RISC assembly and target silencing activity in the presence or absence of Dicer in mammals. Our data show that, unlike the well-characterized fly Ago2-RISC assembly pathway, mammalian Dicer is dispensable for asymmetric RISC loading in vivo and in vitro.

  12. Point-of-Care Test Equipment for Flexible Laboratory Automation.

    Science.gov (United States)

    You, Won Suk; Park, Jae Jun; Jin, Sung Moon; Ryew, Sung Moo; Choi, Hyouk Ryeol

    2014-08-01

    Blood tests are some of the core clinical laboratory tests for diagnosing patients. In hospitals, an automated process called total laboratory automation, which relies on a set of sophisticated equipment, is normally adopted for blood tests. Noting that the total laboratory automation system typically requires a large footprint and significant amount of power, slim and easy-to-move blood test equipment is necessary for specific demands such as emergency departments or small-size local clinics. In this article, we present a point-of-care test system that can provide flexibility and portability with low cost. First, the system components, including a reagent tray, dispensing module, microfluidic disk rotor, and photometry scanner, and their functions are explained. Then, a scheduler algorithm to provide a point-of-care test platform with an efficient test schedule to reduce test time is introduced. Finally, the results of diagnostic tests are presented to evaluate the system. © 2014 Society for Laboratory Automation and Screening.

  13. Regulations, Codes, and Standards (RCS) Template for California Hydrogen Dispensing Stations

    Energy Technology Data Exchange (ETDEWEB)

    Rivkin, C.; Blake, C.; Burgess, R.; Buttner, W.; Post, M.

    2012-11-01

    This report explains the Regulations, Codes, and Standards (RCS) requirements for hydrogen dispensing stations in the State of California. The reports shows the basic components of a hydrogen dispensing station in a simple schematic drawing; the permits and approvals that would typically be required for the construction and operation of a hydrogen dispensing station; and a basic permit that might be employed by an Authority Having Jurisdiction (AHJ).

  14. Elimination of water pathogens with solar radiation using an automated sequential batch CPC reactor.

    Science.gov (United States)

    Polo-López, M I; Fernández-Ibáñez, P; Ubomba-Jaswa, E; Navntoft, C; García-Fernández, I; Dunlop, P S M; Schmid, M; Byrne, J A; McGuigan, K G

    2011-11-30

    Solar disinfection (SODIS) of water is a well-known, effective treatment process which is practiced at household level in many developing countries. However, this process is limited by the small volume treated and there is no indication of treatment efficacy for the user. Low cost glass tube reactors, together with compound parabolic collector (CPC) technology, have been shown to significantly increase the efficiency of solar disinfection. However, these reactors still require user input to control each batch SODIS process and there is no feedback that the process is complete. Automatic operation of the batch SODIS process, controlled by UVA-radiation sensors, can provide information on the status of the process, can ensure the required UVA dose to achieve complete disinfection is received and reduces user work-load through automatic sequential batch processing. In this work, an enhanced CPC photo-reactor with a concentration factor of 1.89 was developed. The apparatus was automated to achieve exposure to a pre-determined UVA dose. Treated water was automatically dispensed into a reservoir tank. The reactor was tested using Escherichia coli as a model pathogen in natural well water. A 6-log inactivation of E. coli was achieved following exposure to the minimum uninterrupted lethal UVA dose. The enhanced reactor decreased the exposure time required to achieve the lethal UVA dose, in comparison to a CPC system with a concentration factor of 1.0. Doubling the lethal UVA dose prevented the need for a period of post-exposure dark inactivation and reduced the overall treatment time. Using this reactor, SODIS can be automatically carried out at an affordable cost, with reduced exposure time and minimal user input. Copyright © 2011 Elsevier B.V. All rights reserved.

  15. Elimination of water pathogens with solar radiation using an automated sequential batch CPC reactor

    International Nuclear Information System (INIS)

    Polo-López, M.I.; Fernández-Ibáñez, P.; Ubomba-Jaswa, E.; Navntoft, C.; García-Fernández, I.; Dunlop, P.S.M.; Schmid, M.; Byrne, J.A.

    2011-01-01

    Solar disinfection (SODIS) of water is a well-known, effective treatment process which is practiced at household level in many developing countries. However, this process is limited by the small volume treated and there is no indication of treatment efficacy for the user. Low cost glass tube reactors, together with compound parabolic collector (CPC) technology, have been shown to significantly increase the efficiency of solar disinfection. However, these reactors still require user input to control each batch SODIS process and there is no feedback that the process is complete. Automatic operation of the batch SODIS process, controlled by UVA-radiation sensors, can provide information on the status of the process, can ensure the required UVA dose to achieve complete disinfection is received and reduces user work-load through automatic sequential batch processing. In this work, an enhanced CPC photo-reactor with a concentration factor of 1.89 was developed. The apparatus was automated to achieve exposure to a pre-determined UVA dose. Treated water was automatically dispensed into a reservoir tank. The reactor was tested using Escherichia coli as a model pathogen in natural well water. A 6-log inactivation of E. coli was achieved following exposure to the minimum uninterrupted lethal UVA dose. The enhanced reactor decreased the exposure time required to achieve the lethal UVA dose, in comparison to a CPC system with a concentration factor of 1.0. Doubling the lethal UVA dose prevented the need for a period of post-exposure dark inactivation and reduced the overall treatment time. Using this reactor, SODIS can be automatically carried out at an affordable cost, with reduced exposure time and minimal user input.

  16. Elimination of water pathogens with solar radiation using an automated sequential batch CPC reactor

    Energy Technology Data Exchange (ETDEWEB)

    Polo-Lopez, M.I., E-mail: mpolo@psa.es [Plataforma Solar de Almeria - CIEMAT, PO Box 22, 04200 Tabernas, Almeria (Spain); Fernandez-Ibanez, P., E-mail: pilar.fernandez@psa.es [Plataforma Solar de Almeria - CIEMAT, PO Box 22, 04200 Tabernas, Almeria (Spain); Ubomba-Jaswa, E., E-mail: euniceubombajaswa@yahoo.com [Natural Resources and the Environment, CSIR, PO Box 395, Pretoria (South Africa); Navntoft, C., E-mail: christian.navntoft@solarmate.com.ar [Instituto de Investigacion e Ingenieria Ambiental, Universidad Nacional de San Martin (3iA-UNSAM), Peatonal Belgrano 3563, B1650ANQ San Martin (Argentina); Universidad Tecnologica Nacional - Facultad Regional Buenos Aires - Departamento de Ingenieria Civil - Laboratorio de Estudios sobre Energia Solar, (UTN-FRBA-LESES), Mozart 2300, (1407) Ciudad Autonoma de Buenos Aires, Republica Argentina (Argentina); Garcia-Fernandez, I., E-mail: irene.garcia@psa.es [Plataforma Solar de Almeria - CIEMAT, PO Box 22, 04200 Tabernas, Almeria (Spain); Dunlop, P.S.M., E-mail: psm.dunlop@ulster.ac.uk [Department of Physiology and Medical Physics, Royal College of Surgeons in Ireland, Dublin 2 (Ireland); Schmid, M. [Department of Physiology and Medical Physics, Royal College of Surgeons in Ireland, Dublin 2 (Ireland); Byrne, J.A., E-mail: j.byrne@ulster.ac.uk [Department of Physiology and Medical Physics, Royal College of Surgeons in Ireland, Dublin 2 (Ireland); and others

    2011-11-30

    Solar disinfection (SODIS) of water is a well-known, effective treatment process which is practiced at household level in many developing countries. However, this process is limited by the small volume treated and there is no indication of treatment efficacy for the user. Low cost glass tube reactors, together with compound parabolic collector (CPC) technology, have been shown to significantly increase the efficiency of solar disinfection. However, these reactors still require user input to control each batch SODIS process and there is no feedback that the process is complete. Automatic operation of the batch SODIS process, controlled by UVA-radiation sensors, can provide information on the status of the process, can ensure the required UVA dose to achieve complete disinfection is received and reduces user work-load through automatic sequential batch processing. In this work, an enhanced CPC photo-reactor with a concentration factor of 1.89 was developed. The apparatus was automated to achieve exposure to a pre-determined UVA dose. Treated water was automatically dispensed into a reservoir tank. The reactor was tested using Escherichia coli as a model pathogen in natural well water. A 6-log inactivation of E. coli was achieved following exposure to the minimum uninterrupted lethal UVA dose. The enhanced reactor decreased the exposure time required to achieve the lethal UVA dose, in comparison to a CPC system with a concentration factor of 1.0. Doubling the lethal UVA dose prevented the need for a period of post-exposure dark inactivation and reduced the overall treatment time. Using this reactor, SODIS can be automatically carried out at an affordable cost, with reduced exposure time and minimal user input.

  17. The 340B discount program: outpatient prescription dispensing patterns through contract pharmacies in 2012.

    Science.gov (United States)

    Clark, Bobby L; Hou, John; Chou, Chia-Hung; Huang, Elbert S; Conti, Rena

    2014-11-01

    Section 340B of the Public Health Service Act provides qualified organizations serving vulnerable populations with deep discounts for some outpatient medications. A 2010 regulatory change widely expanded the 340B program's reach, allowing these organizations to contract with retail pharmacies to dispense medications for eligible patients. Little is known about which medications are dispensed by contract pharmacies under the expanded program. We provide the first comparison of 340B prescriptions and all prescriptions dispensed in contract pharmacies. We used 2012 data from Walgreens, the national leader in 340B contract pharmacies. Medications used to treat chronic conditions such as diabetes, high cholesterol levels, asthma, and depression accounted for an overwhelming majority of all prescriptions dispensed at Walgreens as part of the 340B program. A higher percentage of antiretrovirals used to treat HIV/AIDS were dispensed through 340B prescriptions than through all prescriptions dispensed at Walgreens. The majority of 340B prescriptions dispensed at Walgreens originated at tuberculosis clinics, consolidated health centers, disproportionate-share hospitals, and Ryan White clinics. Our results suggest that 340B contract pharmacies dispense medications used to treat Americans' chronic disease burden and disproportionately dispense medications used by key vulnerable populations targeted by the program. Project HOPE—The People-to-People Health Foundation, Inc.

  18. Virtual automation.

    Science.gov (United States)

    Casis, E; Garrido, A; Uranga, B; Vives, A; Zufiaurre, C

    2001-01-01

    Total laboratory automation (TLA) can be substituted in mid-size laboratories by a computer sample workflow control (virtual automation). Such a solution has been implemented in our laboratory using PSM, software developed in cooperation with Roche Diagnostics (Barcelona, Spain), to this purpose. This software is connected to the online analyzers and to the laboratory information system and is able to control and direct the samples working as an intermediate station. The only difference with TLA is the replacement of transport belts by personnel of the laboratory. The implementation of this virtual automation system has allowed us the achievement of the main advantages of TLA: workload increase (64%) with reduction in the cost per test (43%), significant reduction in the number of biochemistry primary tubes (from 8 to 2), less aliquoting (from 600 to 100 samples/day), automation of functional testing, drastic reduction of preanalytical errors (from 11.7 to 0.4% of the tubes) and better total response time for both inpatients (from up to 48 hours to up to 4 hours) and outpatients (from up to 10 days to up to 48 hours). As an additional advantage, virtual automation could be implemented without hardware investment and significant headcount reduction (15% in our lab).

  19. Automation of data acquisition in electron crystallography.

    Science.gov (United States)

    Cheng, Anchi

    2013-01-01

    General considerations for using automation software for acquiring high-resolution images of 2D crystals under low-dose conditions are presented. Protocol modifications specific to this application in Leginon are provided.

  20. Trends in radiopharmaceutical dispensing in a regional nuclear pharmacy

    International Nuclear Information System (INIS)

    Basmadjian, G.P.; Barker, K.; Johnston, J.; Stinchcomb, R.; Tarman, B.; Ice, R.D.

    1983-01-01

    In the last five years, the practice of nuclear medicine has undergone changes due to the advent of new imaging technologies and radiopharmaceuticals. These changes have had an impact upon the number and the type of radiopharmaceuticals dispensed in centralized nuclear pharmacies. With the advent of Computerized Axial Tomography Scanners (CAT), sophistication and wider acceptance of the Ultrasound imaging modality, nuclear medicine has had to change directions from utilizing radiopharmaceuticals for static organ imaging to functional type imaging and to resort to the use of new radiopharmaceuticals or to find other uses for the existing radiopharmaceuticals. The following trends in radiopharmaceutical dispensing in a regional nuclear pharmacy are evident: Brain procedures have declined by about 67% while nuclear cardiology studies have increased by over 2000%. Bone scans have increased by 72% while liver, renal and lung studies have shown no significant increase. These changes will continue as the practice of nuclear medicine concentrates more on functional studies and relegates other studies to newer imaging modalities

  1. The challenge of responsible dispensing: formal education versus professional practice

    Directory of Open Access Journals (Sweden)

    Nadine Judith Bezzegh

    2011-03-01

    Full Text Available The aim of the present study was to evaluate the education of Pharmaceutical Technicians for the activity of responsible dispensing. Based on a questionnaire with open and closed questions, the study sought to characterize the students, identify knowledge and attitudes regarding the Rational Use of Medications while addressing the limits and possibilities of professional and ethical dispensing in practice. In addition, a group dynamics session - focus group - was held as a forum for debate on responsible dispensing. The results showed that students tended to be mature, currently employed and were predominately women. Displaying adequate knowledge on Rational Use of Medications and of the corresponding legislation, the students reported difficulties exercising compatible practice. While the diagnosis pointed to the need for student preparation to enable ethical dispensing, the Focus Group highlighted the possibility for inclusion of a forum for reflection and debate on the ethics of dispensing as part of the Pharmaceutical Technician training.O presente trabalho tem como proposta avaliar a formação do Técnico em Farmácia para o exercício da dispensação responsável. A partir de um questionário com perguntas fechadas e abertas, o estudo envolveu a caracterização dos alunos, a identificação de conhecimentos e atitudes em relação ao Uso Racional dos Medicamentos com vistas ao delineamento dos limites e possibilidades do exercício profissional ético na dispensação. Além disso, foi realizada uma dinâmica grupal - grupo focal - com o objetivo de apreciar a constituição de um espaço de reflexão sobre a dispensação responsável. Os resultados evidenciaram um alunato de maior idade, inserido no mercado de trabalho e predominância de mulheres. Dispondo de conhecimento adequado sobre o Uso Racional dos Medicamentos e da legislação correspondente os alunos fazem referência às dificuldades no exercício de uma pr

  2. An automated system for the preparation of Large Size Dried (LSD) Spikes

    Energy Technology Data Exchange (ETDEWEB)

    Verbruggen, A.; Bauwens, J.; Jakobsson, U.; Eykens, R.; Wellum, R.; Aregbe, Y. [European Commission - Joint Research Centre, Institute for Reference Materials and Measurements (IRMM), Retieseweg 211, B2440 Geel (Belgium); Van De Steene, N. [Nucomat, Mercatorstraat 206, B9100 Sint Niklaas (Belgium)

    2008-07-01

    Large size dried (LSD) spikes have been produced to fulfill the existing requirement for reliable and traceable isotopic reference materials for nuclear safeguards. A system to produce certified nuclear isotopic reference material as a U/Pu mixture in the form of large size dried spikes, comparable to those produced using traditional methods has been installed in collaboration with Nucomat, a company with a recognized reputation in design and development of integrated automated systems. The major components of the system are a robot, two balances, a dispenser and a drying unit fitted into a glove box. The robot is software driven and designed to control all movements inside the glove-box, to identify unambiguously the penicillin vials with a bar-code reader, to dispense the LSD batch solution into the vials and to weigh the amount dispensed. The system functionality has been evaluated and the performance validated by comparing the results from a series of samples dispensed and weighed by the automated system with the results by manual substitution weighing. After applying the proper correction factors to the data from the automated system balance no significant difference was observed between the two. However, an additional component of uncertainty of 3*10{sup -4} is introduced in the uncertainty budget for the certified weights provided by the automatic system. (authors)

  3. An automated system for the preparation of Large Size Dried (LSD) Spikes

    International Nuclear Information System (INIS)

    Verbruggen, A.; Bauwens, J.; Jakobsson, U.; Eykens, R.; Wellum, R.; Aregbe, Y.; Van De Steene, N.

    2008-01-01

    Large size dried (LSD) spikes have been produced to fulfill the existing requirement for reliable and traceable isotopic reference materials for nuclear safeguards. A system to produce certified nuclear isotopic reference material as a U/Pu mixture in the form of large size dried spikes, comparable to those produced using traditional methods has been installed in collaboration with Nucomat, a company with a recognized reputation in design and development of integrated automated systems. The major components of the system are a robot, two balances, a dispenser and a drying unit fitted into a glove box. The robot is software driven and designed to control all movements inside the glove-box, to identify unambiguously the penicillin vials with a bar-code reader, to dispense the LSD batch solution into the vials and to weigh the amount dispensed. The system functionality has been evaluated and the performance validated by comparing the results from a series of samples dispensed and weighed by the automated system with the results by manual substitution weighing. After applying the proper correction factors to the data from the automated system balance no significant difference was observed between the two. However, an additional component of uncertainty of 3*10 -4 is introduced in the uncertainty budget for the certified weights provided by the automatic system. (authors)

  4. Pharmacists' role in opioid overdose: Kentucky pharmacists' willingness to participate in naloxone dispensing.

    Science.gov (United States)

    Freeman, Patricia R; Goodin, Amie; Troske, SuZanne; Strahl, Audra; Fallin, Amanda; Green, Traci C

    To assess pharmacists' willingness to initiate the dispensing of naloxone. As of 2015, Kentucky law permits certified pharmacists to dispense naloxone under a physician-approved protocol. Electronic survey (e-mail) gauging perception of pharmacists' role in opioid overdose and attitudes toward, and barriers to, naloxone dispensing. All Kentucky pharmacists with active licenses in 2015. Ordinal logistic regression was used to estimate the impact of pharmacist characteristics and attitudes on willingness to initiate naloxone dispensing, where the dependent variable was operationalized as a Likert-type question on a scale of 1 (not at all willing) to 6 (very willing). Of 4699 practicing Kentucky pharmacists, 1282 responded, of which 834 were community practitioners (response rate 27.3%). Pharmacists reported varying willingness to initiate naloxone dispensing, with 37.3% very willing (score 5 or 6) and 27.9% not willing (score 1 or 2). However, a majority of pharmacists reported willingness to dispense naloxone with a valid prescription (54.0%, score 5 or 6). Women pharmacists were 1.3 times more likely than men to be willing to initiate naloxone dispensing (95% confidence interval [CI] 1.0-1.6). Those who reported confidence in identifying individuals at risk for overdose were 1.2 times more likely to initiate dispensing, and those who reported confidence in ability to educate patients about overdose were 1.6 times more likely to express willingness to initiate naloxone dispensing (95% CIs, respectively, 1.0-1.3 and 1.4-1.8). Community pharmacists reported barriers to naloxone access at higher rates than pharmacists from other practice settings. Kentucky pharmacists are divided in their willingness to initiate naloxone dispensing; however, those who are confident in their ability to identify overdose risks are more willing. Increasing pharmacist confidence through appropriately designed education programs could facilitate pharmacist participation in naloxone

  5. Automating Finance

    Science.gov (United States)

    Moore, John

    2007-01-01

    In past years, higher education's financial management side has been riddled with manual processes and aging mainframe applications. This article discusses schools which had taken advantage of an array of technologies that automate billing, payment processing, and refund processing in the case of overpayment. The investments are well worth it:…

  6. Library Automation.

    Science.gov (United States)

    Husby, Ole

    1990-01-01

    The challenges and potential benefits of automating university libraries are reviewed, with special attention given to cooperative systems. Aspects discussed include database size, the role of the university computer center, storage modes, multi-institutional systems, resource sharing, cooperative system management, networking, and intelligent…

  7. MANUAL FOOD AND BEVERAGE DISPENSING EQUIPMENT. NATIONAL SANITATION FOUNDATION STANDARD NO. 18.

    Science.gov (United States)

    National Sanitation Foundation, Ann Arbor, MI.

    THIS STANDARD COVERS THE SANITATION REQUIREMENTS FOR EQUIPMENT AND DEVICES WHICH DISPENSE FOOD OR BEVERAGE EITHER IN BULK OR PORTIONS. VENDING MACHINES OR BULK MILK DISPENSING EQUIPMENT ARE NOT COVERED IN THIS STANDARD. ITEMS COVERED INCLUDE THE BASIC PRINCIPLES OF DESIGN AND CONSTRUCTION, FOOD PROTECTION AND FREEDOM FROM HARBORAGES. MINIMUM…

  8. Poorly processed reusable surface disinfection tissue dispensers may be a source of infection.

    Science.gov (United States)

    Kampf, Günter; Degenhardt, Stina; Lackner, Sibylle; Jesse, Katrin; von Baum, Heike; Ostermeyer, Christiane

    2014-01-21

    Reusable surface disinfectant tissue dispensers are used in hospitals in many countries because they allow immediate access to pre-soaked tissues for targeted surface decontamination. On the other hand disinfectant solutions with some active ingredients may get contaminated and cause outbreaks. We determined the frequency of contaminated surface disinfectant solutions in reusable dispensers and the ability of isolates to multiply in different formulations. Reusable tissue dispensers with different surface disinfectants were randomly collected from healthcare facilities. Solutions were investigated for bacterial contamination. The efficacy of two surface disinfectants was determined in suspension tests against two isolated species directly from a contaminated solution or after 5 passages without selection pressure in triplicate. Freshly prepared use solutions were contaminated to determine survival of isolates. 66 dispensers containing disinfectant solutions with surface-active ingredients were collected in 15 healthcare facilities. 28 dispensers from nine healthcare facilities were contaminated with approximately 107 cells per mL of Achromobacter species 3 (9 hospitals), Achromobacter xylosoxidans or Serratia marcescens (1 hospital each). In none of the hospitals dispenser processing had been adequately performed. Isolates regained susceptibility to the disinfectants after five passages without selection pressure but were still able to multiply in different formulations from different manufacturers at room temperature within 7 days. Neglecting adequate processing of surface disinfectant dispensers has contributed to frequent and heavy contamination of use-solutions based on surface active ingredients. Tissue dispenser processing should be taken seriously in clinical practice.

  9. The fabrication of front electrodes of Si solar cell by dispensing printing

    International Nuclear Information System (INIS)

    Kim, Do-Hyung; Ryu, Sung-Soo; Shin, Dongwook; Shin, Jung-Han; Jeong, Jwa-Jin; Kim, Hyeong-Jun; Chang, Hyo Sik

    2012-01-01

    Highlights: ► We propose the process for the front silver electrode by employing dispensing method. ► The dispensing method is a non-contact printing process. ► The electrode by dispensing method has more uniform and narrower shape. ► The dispensing method helped to enhance the efficiency of solar cell by 0.8% absolute. - Abstract: The dispensing printing was applied to fabricate the front electrodes of silicon solar cell. In this method, a micro channel nozzle and normal Ag paste were employed. The aspect ratio and line width of electrodes could be controlled by the process variables such as the inner diameter of nozzle, dispensing speed, discharge pressure, and the gap between wafer and nozzle. For the nozzle with the inner diameter of 50 μm, the line width and aspect ratio of electrode were under 90 μm and more than ∼0.2, respectively. When comparing the efficiency of solar cell prepared by conventional screen printing and the dispensing printing, the latter exhibited 19.1%, which is 0.8% absolute higher than the former even with the same Ag paste. This is because the electrode by dispensing printing has uniform aspect ratio and narrow line width over the length of electrode.

  10. The impact of closed-loop electronic medication management on time to first dose: a comparative study between paper and digital hospital environments.

    Science.gov (United States)

    Austin, Jodie A; Smith, Ian R; Tariq, Amina

    2018-01-22

    Closed-loop electronic medication management systems (EMMS) are recognised as an effective intervention to improve medication safety, yet evidence of their effectiveness in hospitals is limited. Few studies have compared medication turnaround time for a closed-loop electronic versus paper-based medication management environment. To compare medication turnaround times in a paper-based hospital environment with a digital hospital equipped with a closed-loop EMMS, consisting of computerised physician order entry, profiled automated dispensing cabinets packaged with unit dose medications and barcode medication administration. Data were collected during 2 weeks at three private hospital sites (one with closed-loop EMMS) within the same organisation network in Queensland, Australia. Time between scheduled and actual administration times was analysed for first dose of time-critical and non-critical medications located on the ward or sourced via pharmacy. Medication turnaround times at the EMMS site were less compared to the paper-based sites (median, IQR: 35 min, 8-57 min versus 120 min, 30-180 min, P medications, 77% were administered within 60 min of scheduled time at the EMMS site versus 38% for the paper-based sites. Similar difference was observed for non-critical medications, 80% were administered within 60 min of their scheduled time at the EMMS site versus 41% at the paper-based facilities. The study indicates medication turnaround times utilising a closed-loop EMMS are less compared to paper-based systems. This improvement may be attributable to increased accessibility of medications using automated dispensing cabinets and electronic medication administration records flagging tasks to nurses in real time. © 2018 Royal Pharmaceutical Society.

  11. Energy-efficiency potential of water dispensers; Energieeffizienzpotenzial bei Wasser-Dispensern

    Energy Technology Data Exchange (ETDEWEB)

    Grieder, T.

    2003-07-01

    This final report for the Swiss Federal Office of Energy presents the results of study carried out to assess the energy-savings potential available in the operation of water dispensers often found in banks, stores and offices. The energy consumption of three types of dispenser is examined and compared with American 'EnergyStar'-guidelines. The results of measurements made for day and night-time operation are presented and the energy-savings potentials offered by more appropriate operating scenarios are discussed. Recommendations are made to all parties involved, from the dispenser's manufacturer, water-supplier and service organisation through to the end user. For each category, a catalogue of measures that can be taken is presented, including modifications to the dispensers themselves and the installation of timers. Also, the energy consumption of dispensers is compared with that of using traditional mineral water bottles and a small conventional refrigerator.

  12. The tungsten powder study of the dispenser cathode

    International Nuclear Information System (INIS)

    Bao Jixiu; Wan Baofei

    2006-01-01

    The intercorrelation of tungsten powder properties, such as grain size, distribution and morphology, and porous matrix parameters with electron emission capability and longevity of Ba dispenser cathodes has been investigated for the different grain morphologies. It is shown that a fully cleaning step of the tungsten powder is so necessary that the tungsten powder will be reduction of oxide in hydrogen atmosphere above 700 deg. C. The porosity of the tungsten matrix distributes more even and the closed pore is fewer, the average granule size of the tungsten powder distributes more convergent. The porosity of the tungsten matrix and the evaporation of the activator are bigger and the pulse of the cathode is smaller when the granularity is bigger by the analysis of the electronic microscope and diode experiment

  13. The tungsten powder study of the dispenser cathode

    Science.gov (United States)

    Bao, Ji-xiu; Wan, Bao-fei

    2006-06-01

    The intercorrelation of tungsten powder properties, such as grain size, distribution and morphology, and porous matrix parameters with electron emission capability and longevity of Ba dispenser cathodes has been investigated for the different grain morphologies. It is shown that a fully cleaning step of the tungsten powder is so necessary that the tungsten powder will be reduction of oxide in hydrogen atmosphere above 700 °C. The porosity of the tungsten matrix distributes more even and the closed pore is fewer, the average granule size of the tungsten powder distributes more convergent. The porosity of the tungsten matrix and the evaporation of the activator are bigger and the pulse of the cathode is smaller when the granularity is bigger by the analysis of the electronic microscope and diode experiment.

  14. CT angiography of the aorta using 80 kVp in combination with sinogram-affirmed iterative reconstruction and automated tube current modulation: Effects on image quality and radiation dose

    International Nuclear Information System (INIS)

    Boos, Johannes; Aissa, Joel; Lanzman, Rotem S.; Heusch, Philipp; Schimmoller, Lars; Schleich, Christoph; Thomas, Christoph; Antoch, Gerald; Kropil, Patric

    2016-01-01

    The objective of this study was to evaluate image quality and radiation dose of a CT angiography (CTA) protocol using 80 kVp in combination with iterative reconstruction and automated tube current modulation. Ninety-five aortic CTA examinations were included in this study. A novel 80 kVp aortic CTA-protocol with iterative reconstruction was introduced in our department in March 2012 for patients with a body mass index (BMI) below 32 kg/m 2 . The first 72 consecutive examinations were retrospectively assigned to group A (56 patients, 42 men, 14 women, mean age 69.6 ± 10.7years, BMI range 19.7–31.1 kg/m 2 ). For comparison, the last 23 consecutive examinations performed with the old protocol (100 kVp) were assigned to group B (21 patients, 13 men, 8 women, mean age 67.4 ± 11.1years, BMI range 19.7–31.9 kg/m 2 ). Thoracic and abdominal contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR) and aortic attenuation were assessed. Subjective image quality was rated on a 5-point scale (1 = non diagnostic; 5 = excellent). Furthermore, dose length product (DLP) and volumetric computed tomography dose index (CTDI vol ) were analysed. All examinations achieved diagnostic image quality. Attenuation of the aorta was significantly higher in group A compared with B (thoracic: 443.5 ± 90.5 Hounsfield units (HU) vs. 296.0 ± 61.0 HU; abdominal: 426.3 ± 94.2 HU vs. 283.6 ± 60.5 HU; P < 0.05, respectively). CNR, SNR and subjective image quality were comparable between both groups (CNR: 12.8 ± 3.7 vs. 13.0 ± 7.4; SNR 14.4 ± 3.9 vs. 14.9 ± 8.2; subjective image quality: 4.3 ± 0.6 vs. 4.5 ± 0.6; P > 0.05, respectively). CTDI vol and DLP were significantly lower in group A (1.9 ± 0.5 mGy; 139.2 ± 41.1 mGy × cm) as compared with group B (4.2 ± 1.4 mGy; 292.1 ± 91.5 mGy × cm; P < 0.001, respectively). Low-dose CTA of the aorta using 80 kVp with iterative

  15. Influence of container structures and content solutions on dispensing time of ophthalmic solutions

    Directory of Open Access Journals (Sweden)

    Keiji Yoshikawa

    2010-05-01

    Full Text Available Keiji Yoshikawa1, Hiroshi Yamada21Yoshikawa Eye Clinic, Tokyo, Japan; 2Santen Pharmaceutical Co., Ltd., Osaka, JapanPurpose: To investigate the influence of container structures and content solutions on the time of dispensing from eye dropper bottles.Methods: Eye dropper bottle models, solution models (filtrate water/surfactant solution and a dispensing time measuring apparatus were prepared to measure the dispensing time.Results: With filtrate water and pressure thrust load of 0.3 MPa, the dispensing time significantly increased from 1.1 ± 0.5 seconds to 4.6 ± 1.1 seconds depending on the decrease of inner aperture diameters from 0.4 mm to 0.2 mm (P < 0.0001. When using the bottle models with inner aperture diameters of 0.4 mm or larger, the dispensing time became constant. The dispensing time using surfactant solution showed the same tendency as above. When pressure thrust load was large (0.07 MPa, the solution flew out continuously with inner aperture diameters of 0.4 mm or larger and the dispensing time could not be measured. The inner aperture diameter most strongly explained the variation of the dispensing time in both the content solutions in the multiple linear regression analysis (filtrate water: 46%, R2 = 0.462, surfactant solution: 56%, R2 = 0.563.Conclusions: Among content solutions and container structures, the dispensing time was mostly influenced by the diameter of the inner aperture of bottles.Keywords: dispensing time, model eye dropper bottle, model ophthalmic solution, nozzle internal space volume, nozzle inner aperture diameter

  16. Bacterial hand contamination and transfer after use of contaminated bulk-soap-refillable dispensers.

    Science.gov (United States)

    Zapka, Carrie A; Campbell, Esther J; Maxwell, Sheri L; Gerba, Charles P; Dolan, Michael J; Arbogast, James W; Macinga, David R

    2011-05-01

    Bulk-soap-refillable dispensers are prone to extrinsic bacterial contamination, and recent studies demonstrated that approximately one in four dispensers in public restrooms are contaminated. The purpose of this study was to quantify bacterial hand contamination and transfer after use of contaminated soap under controlled laboratory and in-use conditions in a community setting. Under laboratory conditions using liquid soap experimentally contaminated with 7.51 log(10) CFU/ml of Serratia marcescens, an average of 5.28 log(10) CFU remained on each hand after washing, and 2.23 log(10) CFU was transferred to an agar surface. In an elementary-school-based field study, Gram-negative bacteria on the hands of students and staff increased by 1.42 log(10) CFU per hand (26-fold) after washing with soap from contaminated bulk-soap-refillable dispensers. In contrast, washing with soap from dispensers with sealed refills significantly reduced bacteria on hands by 0.30 log(10) CFU per hand (2-fold). Additionally, the mean number of Gram-negative bacteria transferred to surfaces after washing with soap from dispensers with sealed-soap refills (0.06 log(10) CFU) was significantly lower than the mean number after washing with contaminated bulk-soap-refillable dispensers (0.74 log(10) CFU; P soap (P soap from bulk-soap-refillable dispensers can increase the number of opportunistic pathogens on the hands and may play a role in the transmission of bacteria in public settings.

  17. Dispensing processes impact apparent biological activity as determined by computational and statistical analyses.

    Directory of Open Access Journals (Sweden)

    Sean Ekins

    Full Text Available Dispensing and dilution processes may profoundly influence estimates of biological activity of compounds. Published data show Ephrin type-B receptor 4 IC50 values obtained via tip-based serial dilution and dispensing versus acoustic dispensing with direct dilution differ by orders of magnitude with no correlation or ranking of datasets. We generated computational 3D pharmacophores based on data derived by both acoustic and tip-based transfer. The computed pharmacophores differ significantly depending upon dispensing and dilution methods. The acoustic dispensing-derived pharmacophore correctly identified active compounds in a subsequent test set where the tip-based method failed. Data from acoustic dispensing generates a pharmacophore containing two hydrophobic features, one hydrogen bond donor and one hydrogen bond acceptor. This is consistent with X-ray crystallography studies of ligand-protein interactions and automatically generated pharmacophores derived from this structural data. In contrast, the tip-based data suggest a pharmacophore with two hydrogen bond acceptors, one hydrogen bond donor and no hydrophobic features. This pharmacophore is inconsistent with the X-ray crystallographic studies and automatically generated pharmacophores. In short, traditional dispensing processes are another important source of error in high-throughput screening that impacts computational and statistical analyses. These findings have far-reaching implications in biological research.

  18. Evaluation of community pharmacies regarding dispensing practices of antibiotics in two districts of central Nepal.

    Directory of Open Access Journals (Sweden)

    Mukhtar Ansari

    Full Text Available To evaluate the status of community pharmacies, their staff, and practices toward dispensing antibiotics.Cross-sectional, prospective.Community pharmacies in two districts of central Nepal, from March 2016 to May 2016.A systematic random sampling approach was adopted to sample 161 community pharmacies. Data on the registration status of pharmacies, qualification or training of dispensing staff, and the practice of dispensing antibiotics were collected using a pre-tested questionnaire. Face to face interviews were carried out by a previously trained interviewer. Data were analyzed for descriptive and inferential statistics using IBM SPSS Statistics 21.Among 161 community pharmacies, 25% were not registered and most of them were located in rural areas. It was typical (66.5% to dispense antibiotics without prescription and most (91.4% of the staffs involved in dispensing were non-pharmacists. Furthermore, the study revealed common practices of replacing one brand of antibiotic with other brands (66%, dispensing incomplete courses of antibiotics (73%, and not giving any advice regarding antibiotic use (39% or completion of a full course of therapy (80%. There were significant (p < 0.001 relationships between the location of pharmacies (rural vs urban and the qualifications of the pharmacy staff.Dispensing antibiotics without prescription and by non-pharmacists are common in this region. The study also found several issues regarding the irrational use of antibiotics. Thus, there is an urgent need to address these issues and promote the informed use of antibiotics.

  19. Analyzing implementation dynamics using theory-driven evaluation principles: lessons learnt from a South African centralized chronic dispensing model.

    Science.gov (United States)

    Magadzire, Bvudzai Priscilla; Marchal, Bruno; Mathys, Tania; Laing, Richard O; Ward, Kim

    2017-12-04

    Centralized dispensing of essential medicines is one of South Africa's strategies to address the shortage of pharmacists, reduce patients' waiting times and reduce over-crowding at public sector healthcare facilities. This article reports findings of an evaluation of the Chronic Dispensing Unit (CDU) in one province. The objectives of this process evaluation were to: (1) compare what was planned versus the actual implementation and (2) establish the causal elements and contextual factors influencing implementation. This qualitative study employed key informant interviews with the intervention's implementers (clinicians, managers and the service provider) [N = 40], and a review of policy and program documents. Data were thematically analyzed by identifying the main influences shaping the implementation process. Theory-driven evaluation principles were applied as a theoretical framework to explain implementation dynamics. The overall participants' response about the CDU was positive and the majority of informants concurred that the establishment of the CDU to dispense large volumes of medicines is a beneficial strategy to address healthcare barriers because mechanical functions are automated and distribution of medicines much quicker. However, implementation was influenced by the context and discrepancies between planned activities and actual implementation were noted. Procurement inefficiencies at central level caused medicine stock-outs and affected CDU activities. At the frontline, actors were aware of the CDU's implementation guidelines regarding patient selection, prescription validity and management of non-collected medicines but these were adapted to accommodate practical realities and to meet performance targets attached to the intervention. Implementation success was a result of a combination of 'hardware' (e.g. training, policies, implementation support and appropriate infrastructure) and 'software' (e.g. ownership, cooperation between healthcare

  20. High-Precision Dispensing of Nanoliter Biofluids on Glass Pedestal Arrays for Ultrasensitive Biomolecule Detection.

    Science.gov (United States)

    Chen, Xiaoxiao; Liu, Yang; Xu, QianFeng; Zhu, Jing; Poget, Sébastien F; Lyons, Alan M

    2016-05-04

    Precise dispensing of nanoliter droplets is necessary for the development of sensitive and accurate assays, especially when the availability of the source solution is limited. Conventional approaches are limited by imprecise positioning, large shear forces, surface tension effects, and high costs. To address the need for precise and economical dispensing of nanoliter volumes, we developed a new approach where the dispensed volume is dependent on the size and shape of defined surface features, thus freeing the dispensing process from pumps and fine-gauge needles requiring accurate positioning. The surface we fabricated, called a nanoliter droplet virtual well microplate (nVWP), achieves high-precision dispensing (better than ±0.5 nL or ±1.6% at 32 nL) of 20-40 nL droplets using a small source drop (3-10 μL) on isolated hydrophilic glass pedestals (500 μm on a side) bonded to arrays of polydimethylsiloxane conical posts. The sharp 90° edge of the glass pedestal pins the solid-liquid-vapor triple contact line (TCL), averting the wetting of the glass sidewalls while the fluid is prevented from receding from the edge. This edge creates a sufficiently large energy barrier such that microliter water droplets can be poised on the glass pedestals, exhibiting contact angles greater >150°. This approach relieves the stringent mechanical alignment tolerances required for conventional dispensing techniques, shifting the control of dispensed volume to the area circumscribed by the glass edge. The effects of glass surface chemistry and dispense velocity on droplet volume were studied using optical microscopy and high-speed video. Functionalization of the glass pedestal surface enabled the selective adsorption of specific peptides and proteins from synthetic and natural biomolecule mixtures, such as venom. We further demonstrate how the nVWP dispensing platform can be used for a variety of assays, including sensitive detection of proteins and peptides by fluorescence

  1. Plant automation

    International Nuclear Information System (INIS)

    Christensen, L.J.; Sackett, J.I.; Dayal, Y.; Wagner, W.K.

    1989-01-01

    This paper describes work at EBR-II in the development and demonstration of new control equipment and methods and associated schemes for plant prognosis, diagnosis, and automation. The development work has attracted the interest of other national laboratories, universities, and commercial companies. New initiatives include use of new control strategies, expert systems, advanced diagnostics, and operator displays. The unique opportunity offered by EBR-II is as a test bed where a total integrated approach to automatic reactor control can be directly tested under real power plant conditions

  2. Hand sanitizer-dispensing door handles increase hand hygiene compliance: a pilot study.

    Science.gov (United States)

    Babiarz, Lukasz S; Savoie, Brent; McGuire, Mark; McConnell, Lauren; Nagy, Paul

    2014-04-01

    Improving rates of hand hygiene compliance (HHC) has been shown to reduce nosocomial disease. We compared the HHC for a traditional wall-mounted unit and a novel sanitizer-dispensing door handle device in a hospital inpatient ultrasound area. HHC increased 24.5%-77.1% (P sanitizer-dispensing door handle, whereas it remained unchanged for the other rooms. Technical improvements like a sanitizer-dispensing door handle can improve hospital HHC. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  3. Radiological safety and GMP in the bulk batch manufacturing, formulation and dispensing of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Thulasidhasan, A.; Tiwary, Bikash; Kumar, Uma Sheri; Kale, Pooja; Tiwary, Richa; Gaurav, Ananad; Shah, B.K.; Topale, P.D.; Prabhakar, G.; Sachdev, S.S.

    2010-01-01

    Full text: Radiopharmaceutical Program of BRIT is involved in the manufacturing of ready to use radiopharmaceuticals for therapy for the last three decades. Ready to use Radiopharmaceutical products include, 131 I-Sodium iodide solution and capsules for thyroid carcinoma and metastatic lesions, 131 I MIBG injection for diagnosis and therapy of adrenal medullae tumors and their mets, 153 Sm-EDTMP injection and 32 P- Sodium orthophosphate injection for bone pain palliative treatment. BRIT's radiopharmaceutical production facility is a radioisotope laboratory classified as Type-III facility for handling radioisotopes of Group-II, Group-III and Group-IV approved by AERB. This facility meets all the radiological safety requirements as per AERB guidelines. Production of above mentioned radiopharmaceuticals is carried out in Production Plants (PP), β, γ Glove boxes (GB) and Fume hoods (FH). Typical production procedure involves bulk processing, formulation, sterilization and dispensing of doses. Production Plants (PP) are exclusively designed facilities to carry out the production in a radiologically safe manner, at the same time maintaining aseptic conditions required for injectables as per the current GMP. Each production plant has a leak tight Isolator box, made up of high quality SS which has provisions for remote handling devices like, Tongs, dispensing systems, service points for vacuum, gas, compressed air, water and electric power. This Isolator box is shielded from all sides by required amount of lead (2 inch or 4 inch), and has an access port called 'Transport Port Box' with double door transport lock and is equipped with a trolley. Two filter unit systems are fitted at the top of the plant and each unit comprises of activated Charcoal filter and HEPA filter in tandem, this in turn is connected to special exhaust meant for radioactive gases. Similarly, the designs of β, γ Glove boxes (GB) and Fume hoods (FH) also incorporate all radiological safety features

  4. SU-F-T-57: Delivered Activity Accuracy of Radium 223 Dichloride Injections, When Being Administrated for Castration Resistant Prostate Cancer, Symptomatic Bone Metastases. The Impact of Residual Activity in the Spent Syringe and Dispensing Accuracy of Ra 223

    International Nuclear Information System (INIS)

    Jennings, G

    2016-01-01

    Purpose: To quantify the delivered activity accuracy of Radium 223 dichloride injections, when being administrated for castration – resistant prostate cancer, symptomatic bone metastases. The impact of residual activity in the spent syringe and dispensing accuracy of Ra 223. Methods: The administration is by slow intravenous injection over 1 minute followed by double flushing of the 10 mL syringe and IV with saline. Eighty (80) procedures was used to investigate variations in the activity from the amount prescribed (µCi) = 1.35 × Patient weight Kg. The Activity dispensed into a 10mL syringe using a NIST traceable Capintec CRC-25R Chamber and a cross calibrated capintec CRC-15R to measure activity in the syringe immediately before and after administration Results: The patients weight range from 121Ib to 235lb and doses ranging 74.25 µCi to 144.2 µCi. The deviation of dispensed dose vs Prescribed dose average +2.1% with a range of −1.1% to +5.7%. The Dose measured before administration ranges 79.3 µCi to 154.9 µCi. Deviation from the dispensed dose was show to average +2.9% with a range of −0.8% to +7.3%. The average residual dose post injection was 2.5 µCi or 2.2% of the pre injection activity. Ranging from 0.9 µCi to 6.2 µCi, 0.7% to 5.4% respectively. Subtracting the residual activity from that measured activity before injection and comparing it to prescription dose was shown to have an average variation of +2.7% with a range of −0.8% to 7.4%. Conclusion: The case resulted in the 6.2 µCi maximum residual dose had two syringes. A small, 82.8 µCi activity, case resulted in the 7.4% maximum variation in measures less residual verses prescription dose. The average +2.1 % dispenses activity of Ra 223 over the prescription dosage was seen to counteract the average 2.2% residual dosage found to remain in the syringe

  5. SU-F-T-57: Delivered Activity Accuracy of Radium 223 Dichloride Injections, When Being Administrated for Castration Resistant Prostate Cancer, Symptomatic Bone Metastases. The Impact of Residual Activity in the Spent Syringe and Dispensing Accuracy of Ra 223

    Energy Technology Data Exchange (ETDEWEB)

    Jennings, G [Marsden Medical Physics Associates, Denville, NJ (United States)

    2016-06-15

    Purpose: To quantify the delivered activity accuracy of Radium 223 dichloride injections, when being administrated for castration – resistant prostate cancer, symptomatic bone metastases. The impact of residual activity in the spent syringe and dispensing accuracy of Ra 223. Methods: The administration is by slow intravenous injection over 1 minute followed by double flushing of the 10 mL syringe and IV with saline. Eighty (80) procedures was used to investigate variations in the activity from the amount prescribed (µCi) = 1.35 × Patient weight Kg. The Activity dispensed into a 10mL syringe using a NIST traceable Capintec CRC-25R Chamber and a cross calibrated capintec CRC-15R to measure activity in the syringe immediately before and after administration Results: The patients weight range from 121Ib to 235lb and doses ranging 74.25 µCi to 144.2 µCi. The deviation of dispensed dose vs Prescribed dose average +2.1% with a range of −1.1% to +5.7%. The Dose measured before administration ranges 79.3 µCi to 154.9 µCi. Deviation from the dispensed dose was show to average +2.9% with a range of −0.8% to +7.3%. The average residual dose post injection was 2.5 µCi or 2.2% of the pre injection activity. Ranging from 0.9 µCi to 6.2 µCi, 0.7% to 5.4% respectively. Subtracting the residual activity from that measured activity before injection and comparing it to prescription dose was shown to have an average variation of +2.7% with a range of −0.8% to 7.4%. Conclusion: The case resulted in the 6.2 µCi maximum residual dose had two syringes. A small, 82.8 µCi activity, case resulted in the 7.4% maximum variation in measures less residual verses prescription dose. The average +2.1 % dispenses activity of Ra 223 over the prescription dosage was seen to counteract the average 2.2% residual dosage found to remain in the syringe.

  6. WIDAFELS flexible automation systems

    International Nuclear Information System (INIS)

    Shende, P.S.; Chander, K.P.; Ramadas, P.

    1990-01-01

    After discussing the various aspects of automation, some typical examples of various levels of automation are given. One of the examples is of automated production line for ceramic fuel pellets. (M.G.B.)

  7. An Automation Planning Primer.

    Science.gov (United States)

    Paynter, Marion

    1988-01-01

    This brief planning guide for library automation incorporates needs assessment and evaluation of options to meet those needs. A bibliography of materials on automation planning and software reviews, library software directories, and library automation journals is included. (CLB)

  8. All-printed capacitors with continuous solution dispensing technology

    Science.gov (United States)

    Ge, Yang; Plötner, Matthias; Berndt, Andreas; Kumar, Amit; Voit, Brigitte; Pospiech, Doris; Fischer, Wolf-Joachim

    2017-09-01

    Printed electronics have been introduced into the commercial markets in recent years. Various printing technologies have emerged aiming to process printed electronic devices with low cost, environmental friendliness, and compatibility with large areas and flexible substrates. The aim of this study is to propose a continuous solution dispensing technology for processing all-printed thin-film capacitors on glass substrates using a leading-edge printing instrument. Among all printing technologies, this study provides concrete proof of the following outstanding advantages of this technology: high tolerance to inks, high throughput, low cost, and precise pattern transfers. Ag nanoparticle ink based on glycol ethers was used to print the electrodes. To obtain dielectric ink, a copolymer powder of poly(methyl methacrylate-co-benzoylphenyl methacrylate) containing crosslinkable side groups was dissolved in anisole. Various layouts were designed to support multiple electronic applications. Scanning electron microscopy and atomic force microscopy were used to investigate the all-printed capacitor layers formed using the proposed process. Additionally, the printed capacitors were electrically characterized under direct current and alternating current. The measured electrical properties of the printed capacitors were consistent with the theoretical results.

  9. Fascin 1 is dispensable for developmental and tumour angiogenesis

    Directory of Open Access Journals (Sweden)

    Yafeng Ma

    2013-09-01

    The actin bundling protein fascin 1 is not expressed in adult epithelial tissues, but during development it is transiently expressed in many different cell types, and later in adults it is expressed in a subset of immune cells, nervous tissues, endothelial cells, smooth muscle cells and pericytes. In contrast to the wealth of knowledge about the role of fascin 1 in cancer cell migration and invasion, little is known about the involvement of fascin 1 in angiogenesis. We speculated that as angiogenesis involves migration and invasion of tissues by endothelial cells, fascin 1 might have a role in both normal and tumour angiogenesis. Here, we provide evidence that loss of fascin 1 causes relatively minor reductions to angiogenesis during embryonic, postnatal and cancerous development by examining E12.5 hindbrains, postnatal retinas and B16F0 tumour cell allografts in fascin 1-null mice. We also find that in fascin 1 null tissues, endothelial cells display reduced filopodia formation during sprouting. We thus propose that fascin 1 expression promotes angiogenesis via filopodia formation, but is largely dispensable for both normal and tumour angiogenesis.

  10. A case of adverse drug reaction induced by dispensing error.

    Science.gov (United States)

    Gallelli, L; Staltari, O; Palleria, C; Di Mizio, G; De Sarro, G; Caroleo, B

    2012-11-01

    To report about a case of acute renal failure due to absence of communication between physician and patient. A 78 year old man with human immunodeficiency virus (HIV) accessed our hospital and was brought to our attention in August 2011 for severe renal failure. Clinical history revealed that he had been taking highly active antiretroviral therapy with lamivudine/abacavir and fosamprenavir since 2006. In April 2011 due to an augmentation in creatinine plasma levels, a reduction in lamivudine dosage to 100 mg/day and the prescription of abacavir 300 mg/day became necessary. Unfortunately, the patient took both lamivudine and abacavir therefore the association of the two medications (lamivudine/abacavir) lead to asthenia and acute renal failure within a few days. This case emphasizes the importance about how physicians must pay very careful attention during drug prescription, most particularly, as far as elderly patients are concerned. In fact, communication improvement between physicians and patients can prevent increase of adverse drug reactions related to drug dispensing, with consequential reduction of costs in the healthcare system. Copyright © 2012 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  11. Low cost automation

    International Nuclear Information System (INIS)

    1987-03-01

    This book indicates method of building of automation plan, design of automation facilities, automation and CHIP process like basics of cutting, NC processing machine and CHIP handling, automation unit, such as drilling unit, tapping unit, boring unit, milling unit and slide unit, application of oil pressure on characteristics and basic oil pressure circuit, application of pneumatic, automation kinds and application of process, assembly, transportation, automatic machine and factory automation.

  12. Drug-dispensing errors in the hospital pharmacy Erros de dispensação de medicamentos em farmácia hospitalar

    Directory of Open Access Journals (Sweden)

    Tânia Azevedo Anacleto

    2007-01-01

    Full Text Available OBJECTIVE: To determine the dispensing error rate and to identify factors associated with them, and to propose prevention actions. METHODS: A cross-sectional study focusing on the occurrence of dispensing errors in a general hospital in Belo Horizonte that uses a mixed system (a combination of multidose and unit dose systems of collective and individualized dosing. RESULTS: A total of 422 prescription order forms were analyzed, registering 81.8% with at least 1 dispensing error. Opportunities for errors were higher in the pretyped prescription order forms (odds ratio = 4.5; P OBJETIVO: Determinar a taxa de erros de dispensação e identificar fatores associados, propondo ações de prevenção. MÉTODOS: Estudo transversal investigou-se a ocorrência de erros de dispensação em um hospital geral de Belo Horizonte que emprega um sistema misto de dose coletiva e individualizada. RESULTADOS: Foram analisadas 422 prescrições, registrando em 81,8% destas pelo menos um erro de dispensação. Oportunidades de erros foram maiores nas prescrições pré-digitadas (Odds Ratio=4,5; p<0,001, naquelas com nove ou mais medicamentos (Odds Ratio=4,0; p<0,001 e com os injetáveis (Odds Ratio=5,0; p<0,001. Uma das equipes de profissionais apresentou maior chance de erros (Odds Ratio=2,0; p=0,02. A análise multivariada ratifica estes resultados. CONCLUSÃO: Conclui-se que o sistema de dispensação da farmácia apresenta muitas falhas latentes e poucas defesas, com diversas condições que predispõe a ocorrência de erros, contribuindo para a elevada taxa registrada.

  13. Dispensing Equipment Testing with Mid-Level Ethanol/Gasoline Test Fluid: Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Boyce, K.; Chapin, J. T.

    2010-11-01

    The National Renewable Energy Laboratory's (NREL) Nonpetroleum-Based Fuel Task addresses the hurdles to commercialization of biomass-derived fuels and fuel blends. One such hurdle is the unknown compatibility of new fuels with current infrastructure, such as the equipment used at service stations to dispense fuel into automobiles. The U.S. Department of Energy's (DOE) Vehicle Technology Program and the Biomass Program have engaged in a joint project to evaluate the potential for blending ethanol into gasoline at levels higher than nominal 10 volume percent. This project was established to help DOE and NREL better understand any potentially adverse impacts caused by a lack of knowledge about the compatibility of the dispensing equipment with ethanol blends higher than what the equipment was designed to dispense. This report provides data about the impact of introducing a gasoline with a higher volumetric ethanol content into service station dispensing equipment from a safety and a performance perspective.

  14. Hand sanitizer dispensers and associated hospital-acquired infections: friend or fomite?

    Science.gov (United States)

    Eiref, Simon D; Leitman, I Michael; Riley, William

    2012-06-01

    Waterless alcohol-based hand sanitizers are an increasingly popular method of hand hygiene and help prevent hospital-acquired infection (HAI). Whether hand sanitizer dispensers (HSDs) may themselves harbor pathogens or act as fomites has not been reported. All HSDs in the surgical intensive care unit of an urban teaching hospital were cultured at three sites: The dispenser lever, the rear underside, and the area surrounding the dispensing nozzle. All HSDs yielded one or more bacterial species, including commensal skin flora and enteric gram-negative bacilli. Colonization was greatest on the lever, where there is direct hand contact. Hand sanitizer dispensers can become contaminated with pathogens that cause HAI and thus are potential fomites.

  15. Automated Budget System -

    Data.gov (United States)

    Department of Transportation — The Automated Budget System (ABS) automates management and planning of the Mike Monroney Aeronautical Center (MMAC) budget by providing enhanced capability to plan,...

  16. The association between lifting an administrative restriction on antidepressant dispensing and treatment patterns in Iceland

    DEFF Research Database (Denmark)

    Thengilsdottir, G; Gardarsdottir, H; Almarsdóttir, Anna Birna

    2013-01-01

    On March 1st 2009, restrictions on the dispensing of selective serotonin reuptake inhibitors (SSRI) in Iceland were lifted. Incident rates and changes in early discontinuation and switching before and after the change were investigated.......On March 1st 2009, restrictions on the dispensing of selective serotonin reuptake inhibitors (SSRI) in Iceland were lifted. Incident rates and changes in early discontinuation and switching before and after the change were investigated....

  17. Robotic automation of medication-use management.

    Science.gov (United States)

    Enright, S M

    1993-11-01

    In the October 1993 issue of Physician Assistant, we published "Robots for Health Care," the first of two articles on the medical applications of robotics. That article discussed ways in which robots could help patients with manipulative disabilities to perform activities of daily living and hold paid employment; transfer patients from bed to chair and back again; add precision to the most exacting surgical procedures; and someday carry out diagnostic and therapeutic techniques from within the human body. This month, we are pleased to offer an article by Sharon Enright, an authority on pharmacy operations, who considers how an automated medication-management system that makes use of bar-code technology is capable of streamlining drug dispensing, controlling safety, increasing cost-effectiveness, and ensuring accurate and complete record-keeping.

  18. Automation 2017

    CERN Document Server

    Zieliński, Cezary; Kaliczyńska, Małgorzata

    2017-01-01

    This book consists of papers presented at Automation 2017, an international conference held in Warsaw from March 15 to 17, 2017. It discusses research findings associated with the concepts behind INDUSTRY 4.0, with a focus on offering a better understanding of and promoting participation in the Fourth Industrial Revolution. Each chapter presents a detailed analysis of a specific technical problem, in most cases followed by a numerical analysis, simulation and description of the results of implementing the solution in a real-world context. The theoretical results, practical solutions and guidelines presented are valuable for both researchers working in the area of engineering sciences and practitioners looking for solutions to industrial problems. .

  19. Marketing automation

    Directory of Open Access Journals (Sweden)

    TODOR Raluca Dania

    2017-01-01

    Full Text Available The automation of the marketing process seems to be nowadays, the only solution to face the major changes brought by the fast evolution of technology and the continuous increase in supply and demand. In order to achieve the desired marketing results, businessis have to employ digital marketing and communication services. These services are efficient and measurable thanks to the marketing technology used to track, score and implement each campaign. Due to the technical progress, the marketing fragmentation, demand for customized products and services on one side and the need to achieve constructive dialogue with the customers, immediate and flexible response and the necessity to measure the investments and the results on the other side, the classical marketing approached had changed continue to improve substantially.

  20. [Quality evaluation of rhubarb dispensing granules based on multi-component simultaneous quantitative analysis and bioassay].

    Science.gov (United States)

    Tan, Peng; Zhang, Hai-Zhu; Zhang, Ding-Kun; Wu, Shan-Na; Niu, Ming; Wang, Jia-Bo; Xiao, Xiao-He

    2017-07-01

    This study attempts to evaluate the quality of Chinese formula granules by combined use of multi-component simultaneous quantitative analysis and bioassay. The rhubarb dispensing granules were used as the model drug for demonstrative study. The ultra-high performance liquid chromatography (UPLC) method was adopted for simultaneously quantitative determination of the 10 anthraquinone derivatives (such as aloe emodin-8-O-β-D-glucoside) in rhubarb dispensing granules; purgative biopotency of different batches of rhubarb dispensing granules was determined based on compound diphenoxylate tablets-induced mouse constipation model; blood activating biopotency of different batches of rhubarb dispensing granules was determined based on in vitro rat antiplatelet aggregation model; SPSS 22.0 statistical software was used for correlation analysis between 10 anthraquinone derivatives and purgative biopotency, blood activating biopotency. The results of multi-components simultaneous quantitative analysisshowed that there was a great difference in chemical characterizationand certain differences inpurgative biopotency and blood activating biopotency among 10 batches of rhubarb dispensing granules. The correlation analysis showed that the intensity of purgative biopotency was significantly correlated with the content of conjugated anthraquinone glycosides (Panalysis and bioassay can achieve objective quantification and more comprehensive reflection on overall quality difference among different batches of rhubarb dispensing granules. Copyright© by the Chinese Pharmaceutical Association.

  1. Separation of prescribing and dispensing in Malaysia: the history and challenges.

    Science.gov (United States)

    Tiong, John Jeh Lung; Mai, Chun Wai; Gan, Pou Wee; Johnson, James; Mak, Vivienne Sook Li

    2016-08-01

    This article serves as an update to the work by Shafie et al. (2012) which previously reviewed the benefits of policies separating prescribing and dispensing in various countries to advocate its implementation in Malaysia. This article seeks to strengthen the argument by highlighting not only the weaknesses of the Malaysian health care system from the historical, professional and economic viewpoints but also the shortcomings of both medical and pharmacy professions in the absence of separation of dispensing. It also provides a detailed insight into the ongoing initiatives taken to consolidate the role of pharmacists in the health care system in the advent of separation of dispensing. Under the two tier system in Malaysia at present, the separation of prescribing and dispensing is implemented only in government hospitals. The absence of this separation in the private practices has led to possible profit-oriented medical and pharmacy practices which hinder safe and cost-effective delivery of health services. The call for separation of dispensing has gained traction over the years despite various hurdles ranging from the formidable resistance from the medical fraternity to the public's scepticism towards the new policy. With historical testament and present evidence pointing towards the merits of a system in which doctors prescribe and pharmacists dispense, the implementation of this health care model is justified. © 2016 The Authors. IJPP © 2016 Royal Pharmaceutical Society.

  2. Nanoliter Centrifugal Liquid Dispenser Coupled with Superhydrophobic Microwell Array Chips for High-Throughput Cell Assays

    Directory of Open Access Journals (Sweden)

    Yuyi Wang

    2018-06-01

    Full Text Available Microfluidic systems have been regarded as a potential platform for high-throughput screening technology in drug discovery due to their low sample consumption, high integration, and easy operation. The handling of small-volume liquid is an essential operation in microfluidic systems, especially in investigating large-scale combination conditions. Here, we develop a nanoliter centrifugal liquid dispenser (NanoCLD coupled with superhydrophobic microwell array chips for high-throughput cell-based assays in the nanoliter scale. The NanoCLD consists of a plastic stock block with an array of drilled through holes, a reagent microwell array chip (reagent chip, and an alignment bottom assembled together in a fixture. A simple centrifugation at 800 rpm can dispense ~160 nL reagents into microwells in 5 min. The dispensed reagents are then delivered to cells by sandwiching the reagent chip upside down with another microwell array chip (cell chip on which cells are cultured. A gradient of doxorubicin is then dispensed to the cell chip using the NanoCLD for validating the feasibility of performing drug tests on our microchip platform. This novel nanoliter-volume liquid dispensing method is simple, easy to operate, and especially suitable for repeatedly dispensing many different reagents simultaneously to microwells.

  3. Pharmacy Automation in Navy Medicine: A Study of Naval Medical Center San Diego

    Science.gov (United States)

    2015-09-01

    Whittlesea, C. (2013). The impact of automation on workload and dispensing errors in a hospital pharmacy . International Journal of Pharmacy Practice , 21...Welsh NHS hospitals. International Journal of Pharmacy Practice , 16, 175–188. Lin, A. C., Huang, Y.-C., Punches, G., & Chen, Y. (2007). Effect of a...expectations of outpatient pharmacy services in a teaching hospital. International Journal of Pharmacy Medicine , 5(3), 128–132. 79 INITIAL

  4. Confined prostate cancer treated by conformational irradiation with intensity modulation with or without echography repositioning: is the dose received equivalent to the prescribed dose?; Cancer prostatique localise traite par irradiation conformationnelle avec modulation d'intensite avec ou sans repositionnement echographique: la dose recue est-elle equivalente a la dose prescrite?

    Energy Technology Data Exchange (ETDEWEB)

    Arnaud, A.; Peignaux, K.; Brenier, J.P.; Truc, G.; Naudy, S.; Maingon, P.; Crehange, G. [Centre Georges-Francois Leclerc, Dept. de Radiotherapie, 21 - Dijon (France); Regis, A. [CHU le Bocage, Service de Radiodiagnostic, 21 - Dijon (France); Deville, C.; Bonnetain, F. [Centre Georges-Francois Leclerc, Dept. de Biostatique, 21 - Dijon (France)

    2006-11-15

    The results suggest it would be possible to dispense a homogenous dose in agreement with the ICRU recommendations, nearer than the forward looking dose when the daily echographic repositioning is applied. This repositioning does not influence significantly the dosimetry for the risk organs. These results will validated in a bigger population. (N.C.)

  5. Impact of alternative interventions on changes in generic dispensing rates.

    Science.gov (United States)

    O'Malley, A James; Frank, Richard G; Kaddis, Atheer; Rothenberg, Barbara M; McNeil, Barbara J

    2006-10-01

    To evaluate the effectiveness of four alternative interventions (member mailings, advertising campaigns, free generic drug samples to physicians, and physician financial incentives) used by a major health insurer to encourage its members to switch to generic drugs. Using claim-level data from Blue Cross Blue Shield of Michigan, we evaluated the success of four interventions implemented during 2000-2003 designed to increase the use of generic drugs among its members. Around 13 million claims involving seven important classes of drugs were used to assess the effectiveness of the interventions. For each intervention a control group was developed that most closely resembled the corresponding intervention group. Logistic regression models with interaction effects between the treatment group (intervention versus control) and the status of the intervention (active versus not active) were used to evaluate if the interventions had an effect on the generic dispensing rate (GDR). Because the mail order pharmacy was considered more aggressive at converting prescriptions to generics, separate generic purchasing models were fitted to retail and mail order claims. In secondary analyses separate models were also fitted to claims involving a new condition and claims refilled for preexisting conditions. The interventions did not appear to increase the market penetration of generic drugs for either retail or mail order claims, or for claims involving new or preexisting conditions. In addition, we found that the ratio of copayments for brand name to generic drugs had a large positive effect on the GDR. The interventions did not appear to directly influence the GDR. Financial incentives expressed to consumers through benefit designs have a large influence on their switching to generic drugs and on the less-costly mail-order mode of purchase.

  6. Justice Dispensation through the Alternative Dispute Resolution System in India

    Directory of Open Access Journals (Sweden)

    Krishna Agrawal

    2014-01-01

    Full Text Available The Law Commission of India in its 222nd report emphasized the need for Alternative Disputes Resolution (ADR for the dispensation of justice, because the courts are inaccessible owing to various factors, e.g., poverty, social and political backwardness, illiteracy, ignorance, procedural formalities and inordinate delay in judgments. During the ancient period the disputes were resolved in an informal manner by neutral third persons or people’s court in villages and it continued till the middle of the 20th century. Unfortunately, after the Independence of India in 1947, this system was dissuaded and the government permitted to continue the adversarial system of justice. In 1980, a committee was set up. It recommended Lok Adalats (People’s Courts. In 1987, the Legal Services Authorities Act was enacted. This Act obligates the states to provide free legal aid to poor persons. Besides this, the Act provides for the establishment of permanent Lok Adalats.This is one of the important modes of ADR. Lok Adalats have been established in all the districts of the country. They bring conciliatory settlement in complicated cases arising out of matrimonial, landlord-tenants, property, insurance and commercial disputes. There are four methods of ADR, viz., negotiation, mediation, conciliation and arbitration. Mediation and arbitration are widely preferred. They are alternatives to litigation. The Arbitration Act for the first time was enacted in 1889 and it was subsequently amended many times. On the objections raised by the Supreme Court of India and also on the adoption of UNCITRAL Model Law on International Commercial Arbitration, in 1996 Arbitration and Conciliation Act was enacted. This law is almost the same as is almost in all the countries.Further, the Government of India established International Centre for Alternative Disputes Resolution (CADR with the objectives of promotion, propagation, and popularizing the settlement of domestic and

  7. Back bombardment for dispenser and lanthanum hexaboride cathodes

    Directory of Open Access Journals (Sweden)

    Mahmoud Bakr

    2011-06-01

    Full Text Available The back bombardment (BB effect limits wide usage of thermionic rf guns. The BB effect induces not only ramping-up of a cathode’s temperature and beam current, but also degradation of cavity voltage and beam energy during a macropulse. This paper presents a comparison of the BB effect for the case of dispenser tungsten-base (DC and lanthanum hexaboride (LaB_{6} thermionic rf gun cathodes. For each, particle simulation codes are used to simulate the BB effect and electron beam dynamics in a thermionic rf gun cathode. A semiempirical equation is also used to investigate the stopping range and deposited heat power of BB electrons in the cathode material. A numerical simulation method is used to calculate the change of the cathode temperature and current density during a single macropulse. This is done by solving two differential equations for the rf gun cavity equivalent circuit and one-dimensional thermal diffusion equation. High electron emission and small beam size are required for generation of a high-brightness electron beam, and so in this work the emission properties of the cathode are taken into account. Simulations of the BB effect show that, for a pulse of 6  μs duration, the DC cathode experiences a large change in the temperature compared with LaB_{6}, and a change in current density 6 times higher. Validation of the simulation results is performed using experimental data for beam current beyond the gun exit. The experimental data is well reproduced using the simulation method.

  8. Impact of Pharmacists’ Religious and Personal Beliefs in Dispensing Contraceptives

    Directory of Open Access Journals (Sweden)

    Anna Krupa

    2016-10-01

    Full Text Available Background: Until recently, pharmacies were not permitted to dispense any emergency contraceptives to women to prevent pregnancy. No legal statutes existed under which pharmacists with religious, moral or ethical objections could refuse to fill a prescription for contraceptives, nor were there direct guidelines describing the pharmacist’s professional obligations. Objectives: The purpose of this study is to explore the frequency of cases in which pharmacists have refused, due to their personal beliefs, to provide counsel regarding contraceptives or have refused to refer to a patient to a different pharmacist or healthcare provider. This study will compare and contrast the differences between independent pharmacies and chain pharmacies (i.e. time spent, location, most common recommended contraception. Finally, this study will compare the results evident between male pharmacists and female pharmacists. Method: Quantitative method employed uses two interview questions directed to pharmacists: (1 “I am moving in with my fiancée/boyfriend next month and I have never used contraceptives. What are my options?” (2 “If I use a condom and it breaks, do I have any choices to prevent pregnancy after the fact?” The survey was conducted in two locations, the greater Philadelphia area and Hershey, PA. The survey was conducted through face-to-face interactions with pharmacists, either employed at independent pharmacy or at a chain pharmacy. Data collected from each pharmacist included number of approximate age/gender; minutes spent in each consultation with a patient; the kind of privacy provided during the consultation; and the referrals given, if any. Results: Fifty (50 pharmacists were interviewed. No pharmacist indicated that counseling would be denied, although one (1 pharmacist refused to counsel on Plan B and four (4 pharmacists referred the interviewer to a doctor immediately, indicating that all medications require a prescription. Two (2

  9. Effects of mental demands during dispensing on perceived medication safety and employee well-being: a study of workload in pediatric hospital pharmacies.

    Science.gov (United States)

    Holden, Richard J; Patel, Neal R; Scanlon, Matthew C; Shalaby, Theresa M; Arnold, Judi M; Karsh, Ben-Tzion

    2010-12-01

    Pharmacy workload is a modifiable work system factor believed to affect both medication safety outcomes and employee outcomes, such as job satisfaction. This study sought to measure the effect of workload on safety and employee outcomes in 2 pediatric hospitals and to do so using a novel approach to pharmacy workload measurement. Rather than measuring prescription volume or other similar indicators, this study measured the type and intensity of mental demands experienced during the medication dispensing tasks. The effects of external (interruptions, divided attention, and rushing) and internal (concentration and effort) task demands on perceived medication error likelihood, adverse drug event likelihood, job dissatisfaction, and burnout were statistically estimated using multiple linear and logistic regression. Pharmacists and pharmacy technicians reported high levels of external and internal mental demands during dispensing. The study supported the hypothesis that external demands (interruptions, divided attention, and rushing) negatively impacted medication safety and employee well-being outcomes. However, as hypothesized, increasing levels of internal demands (concentration and effort) were not associated with greater perceived likelihood of error, adverse drug events, or burnout and even had a positive effect on job satisfaction. Replicating a prior study in nursing, this study shows that new conceptualizations and measures of workload can generate important new findings about both detrimental and beneficial effects of workload on patient safety and employee well-being. This study discusses what those findings imply for policy, management, and design concerning automation, cognition, and staffing. Copyright © 2010 Elsevier Inc. All rights reserved.

  10. Effects of mental demands during dispensing on perceived medication safety and employee well being: A study of workload in pediatric hospital pharmacies

    Science.gov (United States)

    Holden, Richard J.; Patel, Neal R.; Scanlon, Matthew C.; Shalaby, Theresa M.; Arnold, Judi M.; Karsh, Ben-Tzion

    2009-01-01

    Background Pharmacy workload is a modifiable work system factor believed to affect both medication safety outcomes and employee outcomes such as job satisfaction. Objectives This study sought to measure the effect of workload on safety and employee outcomes in two pediatric hospitals and to do so using a novel approach to pharmacy workload measurement. Methods Rather than measuring prescription volume or other similar indicators, this study measured the type and intensity of mental demands experienced during the medication dispensing tasks. The effects of external (interruptions, divided attention, rushing) and internal (concentration, effort) task demands on perceived medication error likelihood, adverse drug event likelihood, job dissatisfaction, and burnout were statistically estimated using multiple linear and logistic regression. Results Pharmacists and pharmacy technicians reported high levels of external and internal mental demands during dispensing. The study supported the hypothesis that external demands (interruptions, divided attention, rushing) negatively impacted medication safety and employee well being outcomes. However, as hypothesized, increasing levels of internal demands (concentration and effort) were not associated with greater perceived likelihood of error, adverse drug events, or burnout, and even had a positive effect on job satisfaction. Conclusion Replicating a prior study in nursing, this study shows that new conceptualizations and measures of workload can generate important new findings about both detrimental and beneficial effects of workload on patient safety and employee well being. This study discusses what those findings imply for policy, management, and design concerning automation, cognition, and staffing. PMID:21111387

  11. Both Automation and Paper.

    Science.gov (United States)

    Purcell, Royal

    1988-01-01

    Discusses the concept of a paperless society and the current situation in library automation. Various applications of automation and telecommunications are addressed, and future library automation is considered. Automation at the Monroe County Public Library in Bloomington, Indiana, is described as an example. (MES)

  12. Intelligent control of liquid transfer for the automated synthesis of positron emitting radiopharmaceuticals

    International Nuclear Information System (INIS)

    Iwata, Ren; Ido, Tatsuo; Yamazaki, Shigeki

    1990-01-01

    A method for the intelligent control of liquid transfer, developed for automated synthesis of 2-deoxy-2-[ 18 F]fluoro-D-glucose from [ 18 F]fluoride, is described. A thermal mass flow controller coupled to a personal computer is used to monitor conditions for transferring or passing liquid through a tube or a column. Using this sensor a computer can detect completion of liquid transfer, dispense a stock solution and check the setup conditions of the system. The present feedback control can be readily adapted to other automated syntheses of positron emitting radiopharmaceuticals. (author)

  13. An analysis of the utilisation and expenditure of medicines dispensed for the management of severe asthma.

    LENUS (Irish Health Repository)

    McGowan, B

    2009-03-01

    There are approximately 6,300 people in Ireland with a diagnosis of Chronic Obstructive Pulmonary Disease (COPD) and with a fast growing elderly population the incidence of COPD is likely to increase. This study examines the prescribing patterns of medicines dispensed for the management Asthma\\/COPD in patients over the age of 35 years using the HSE-Primary Care Reimbursement Services (PCRS) prescribing databases. The HSE-PCRS pharmacy claims data, which covers all those over 70 years of age and means tested for those less than 70 years, was analysed for the years 2005\\/2006. Approximately 26,548 (17.9%) of patients who were prescribed a respiratory drug received inhaled short-acting beta2 agonists in combination with a regular standard-dose inhaled corticosteroid. A further 5,044 (3.4%) were also prescribed a regular inhaled long-acting beta2 agonist (salmeterol or formoterol). A total of 2506 patients (6.2%) on combination therapy were co-prescribed four different anti-asthmatic treatments inclusive of oral prednisolone. A small proportion of the patients prescribed a respiratory drug were co-prescribed nicotine replacement therapy (n = 5177, 3.5%). In total there were 9,728 (6.2%) patients prescribed a mucolytic drug in combination with a respiratory drug and the rate of co-prescribing with antibiotics was 22%. COPD is a debilitating disease that is primarily caused by smoking and is therefore largely preventable. The HSE-PCRS pharmacy claims data is a valuable tool for helping to assess the burden of this disease in the Irish context.

  14. An automated thermoluminescence dosimetry (TLD) system

    International Nuclear Information System (INIS)

    Kicken, P.J.H.; Huyskens, C.J.

    1979-01-01

    In the Health Physics Division of the Eindhoven University of Technology work is going on in developing an automated TLD-system. Process automization, statistical computation, dose calculation as well as dose recording are carried out, using a microcomputer and floppy disk unit. The main features of this TLD-system are its low costs, flexibility, easy to operate, and the feasibility for use in routine dosimetry as well as in complex TLD research. Because of its modular set-up several components of the system are multifunctional in other operations. The system seems suited for medium sized Health Physics groups. (Auth.)

  15. Automated ISS Flight Utilities

    Science.gov (United States)

    Offermann, Jan Tuzlic

    2016-01-01

    During my internship at NASA Johnson Space Center, I worked in the Space Radiation Analysis Group (SRAG), where I was tasked with a number of projects focused on the automation of tasks and activities related to the operation of the International Space Station (ISS). As I worked on a number of projects, I have written short sections below to give a description for each, followed by more general remarks on the internship experience. My first project is titled "General Exposure Representation EVADOSE", also known as "GEnEVADOSE". This project involved the design and development of a C++/ ROOT framework focused on radiation exposure for extravehicular activity (EVA) planning for the ISS. The utility helps mission managers plan EVAs by displaying information on the cumulative radiation doses that crew will receive during an EVA as a function of the egress time and duration of the activity. SRAG uses a utility called EVADOSE, employing a model of the space radiation environment in low Earth orbit to predict these doses, as while outside the ISS the astronauts will have less shielding from charged particles such as electrons and protons. However, EVADOSE output is cumbersome to work with, and prior to GEnEVADOSE, querying data and producing graphs of ISS trajectories and cumulative doses versus egress time required manual work in Microsoft Excel. GEnEVADOSE automates all this work, reading in EVADOSE output file(s) along with a plaintext file input by the user providing input parameters. GEnEVADOSE will output a text file containing all the necessary dosimetry for each proposed EVA egress time, for each specified EVADOSE file. It also plots cumulative dose versus egress time and the ISS trajectory, and displays all of this information in an auto-generated presentation made in LaTeX. New features have also been added, such as best-case scenarios (egress times corresponding to the least dose), interpolated curves for trajectories, and the ability to query any time in the

  16. Computed tomography of head: impact of the use of automatic exposure control; Doses em tomografia computadorizada de crânio: impacto do uso do controle automático de exposição

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Giordana Salvi de Souza; Froner, Ana Paula Pastre; Silva, Ana Maria Marques da, E-mail: giordana.souza@acad.pucrs.br [Pontificia Universidade catolica do Rio Grande do Sul (PUC-RS), Porto Alegre, RS (Brazil). Núcleo de Pesquisa em Imagens Médicas

    2017-07-01

    The use of dose reduction systems in computed tomography is particularly important for pediatric patients, who have a high radiosensitivity, since they are in the growing phase. The aim of this study was to evaluate the impact of Siemens AEC Care Dose system use on dose estimation in head computed tomography scans in pediatric patients. A retrospective study was conducted with 199 computed tomography head scans of pediatric patients, divided in different age groups, on a 16-channel Siemens Emotion scanner. It was possible to observe, for all age groups, that the use of AEC Care Dose system, not only reduced CTDI{sub vol}, but also the interquartile range, reducing the total dose in the investigated population. Concluding, AEC Care Dose system models the tube current according to the patient's dimensions, reducing individual and collective dose without affecting the diagnostic quality . (author)

  17. Occurrence of heterotrophic and coliform bacteria in liquid hand soaps from bulk refillable dispensers in public facilities.

    Science.gov (United States)

    Chattman, Marisa; Gerba, Sheri L; Maxwell, Charles P

    2011-03-01

    The goal of the study discussed in this article was to determine the occurrence of heterotrophic and coliform bacteria in liquid soap from bulk refillable dispensers, obtained from restrooms in a variety of public facilities. A total of 541 samples was collected from five U.S. cities. Liquid soap from dispensers in public areas was found to contain heterotrophic and coliform bacterial numbers averaging more than 106 CFU/mL in 24.8% of the dispensers.

  18. Calculational Tool for Skin Contamination Dose Assessment

    CERN Document Server

    Hill, R L

    2002-01-01

    Spreadsheet calculational tool was developed to automate the calculations preformed for dose assessment of skin contamination. This document reports on the design and testing of the spreadsheet calculational tool.

  19. Effective reprocessing of reusable dispensers for surface disinfection tissues – the devil is in the details

    Science.gov (United States)

    Kampf, Günter; Degenhardt, Stina; Lackner, Sibylle; Ostermeyer, Christiane

    2014-01-01

    Background: It has recently been reported that reusable dispensers for surface disinfection tissues may be contaminated, especially with adapted Achromobacter species 3, when products based on surface-active ingredients are used. Fresh solution may quickly become recontaminated if dispensers are not processed adequately. Methods: We evaluated the abilities of six manual and three automatic processes for processing contaminated dispensers to prevent recolonisation of a freshly-prepared disinfectant solution (Mikrobac forte 0.5%). Dispensers were left at room temperature for 28 days. Samples of the disinfectant solution were taken every 7 days and assessed quantitatively for bacterial contamination. Results: All automatic procedures prevented recolonisation of the disinfectant solution when a temperature of 60–70°C was ensured for at least 5 min, with or without the addition of chemical cleaning agents. Manual procedures prevented recontamination of the disinfectant solution when rinsing with hot water or a thorough cleaning step was performed before treating all surfaces with an alcohol-based disinfectant or an oxygen-releaser. Other cleaning and disinfection procedures, including the use of an alcohol-based disinfectant, did not prevent recolonisation. Conclusions: These results indicate that not all processes are effective for processing reusable dispensers for surface-disinfectant tissues, and that a high temperature during the cleaning step or use of a biofilm-active cleaning agent are essential. PMID:24653973

  20. Effective reprocessing of reusable dispensers for surface disinfection tissues – the devil is in the details

    Directory of Open Access Journals (Sweden)

    Kampf, Günter

    2014-03-01

    Full Text Available [english] Background: It has recently been reported that reusable dispensers for surface disinfection tissues may be contaminated, especially with adapted , when products based on surface-active ingredients are used. Fresh solution may quickly become recontaminated if dispensers are not processed adequately. Methods: We evaluated the abilities of six manual and three automatic processes for processing contaminated dispensers to prevent recolonisation of a freshly-prepared disinfectant solution (Mikrobac forte 0.5%. Dispensers were left at room temperature for 28 days. Samples of the disinfectant solution were taken every 7 days and assessed quantitatively for bacterial contamination. Results: All automatic procedures prevented recolonisation of the disinfectant solution when a temperature of 60–70°C was ensured for at least 5 min, with or without the addition of chemical cleaning agents. Manual procedures prevented recontamination of the disinfectant solution when rinsing with hot water or a thorough cleaning step was performed before treating all surfaces with an alcohol-based disinfectant or an oxygen-releaser. Other cleaning and disinfection procedures, including the use of an alcohol-based disinfectant, did not prevent recolonisation.Conclusions: These results indicate that not all processes are effective for processing reusable dispensers for surface-disinfectant tissues, and that a high temperature during the cleaning step or use of a biofilm-active cleaning agent are essential.

  1. Automated spike preparation system for Isotope Dilution Mass Spectrometry (IDMS)

    International Nuclear Information System (INIS)

    Maxwell, S.L. III; Clark, J.P.

    1990-01-01

    Isotope Dilution Mass Spectrometry (IDMS) is a method frequently employed to measure dissolved, irradiated nuclear materials. A known quantity of a unique isotope of the element to be measured (referred to as the ''spike'') is added to the solution containing the analyte. The resulting solution is chemically purified then analyzed by mass spectrometry. By measuring the magnitude of the response for each isotope and the response for the ''unique spike'' then relating this to the known quantity of the ''spike'', the quantity of the nuclear material can be determined. An automated spike preparation system was developed at the Savannah River Site (SRS) to dispense spikes for use in IDMS analytical methods. Prior to this development, technicians weighed each individual spike manually to achieve the accuracy required. This procedure was time-consuming and subjected the master stock solution to evaporation. The new system employs a high precision SMI Model 300 Unipump dispenser interfaced with an electronic balance and a portable Epson HX-20 notebook computer to automate spike preparation

  2. Electronic vending machines for dispensing rapid HIV self-testing kits: a case study.

    Science.gov (United States)

    Young, Sean D; Klausner, Jeffrey; Fynn, Risa; Bolan, Robert

    2014-02-01

    This short report evaluates the feasibility of using electronic vending machines for dispensing oral, fluid, rapid HIV self-testing kits in Los Angeles County. Feasibility criteria that needed to be addressed were defined as: (1) ability to find a manufacturer who would allow dispensing of HIV testing kits and could fit them to the dimensions of a vending machine, (2) ability to identify and address potential initial obstacles, trade-offs in choosing a machine location, and (3) ability to gain community approval for implementing this approach in a community setting. To address these issues, we contracted a vending machine company who could supply a customized, Internet-enabled machine that could dispense HIV kits and partnered with a local health center available to host the machine onsite and provide counseling to participants, if needed. Vending machines appear to be feasible technologies that can be used to distribute HIV testing kits.

  3. Automation of analytical systems in power cycles

    International Nuclear Information System (INIS)

    Staub Lukas

    2008-01-01

    'Automation' is a widely used term in instrumentation and is often applied to signal exchange, PLC and SCADA systems. Common use, however, does not necessarily described autonomous operation of analytical devices. We define an automated analytical system as a black box with an input (sample) and an output (measured value). In addition we need dedicated status lines for assessing the validities of the input for our black box and the output for subsequent systems. We will discuss input parameters, automated analytical processes and output parameters. Further considerations will be given to signal exchange and integration into the operating routine of a power plant. Local control loops (chemical dosing) and the automation of sampling systems are not discussed here. (author)

  4. Designing an automated blood fractionation system.

    Science.gov (United States)

    McQuillan, Adrian C; Sales, Sean D

    2008-04-01

    UK Biobank will be collecting blood samples from a cohort of 500 000 volunteers and it is expected that the rate of collection will peak at approximately 3000 blood collection tubes per day. These samples need to be prepared for long-term storage. It is not considered practical to manually process this quantity of samples so an automated blood fractionation system is required. Principles of industrial automation were applied to the blood fractionation process leading to the requirement of developing a vision system to identify the blood fractions within the blood collection tube so that the fractions can be accurately aspirated and dispensed into micro-tubes. A prototype was manufactured and tested on a range of human blood samples collected in different tube types. A specially designed vision system was capable of accurately measuring the position of the plasma meniscus, plasma/buffy coat interface and the red cells/buffy coat interface within a vacutainer. A rack of 24 vacutainers could be processed in blood fractionation system offers a solution to the problem of processing human blood samples collected in vacutainers in a consistent manner and provides a means of ensuring data and sample integrity.

  5. [Dispensing prescriptions to persons affiliated with the Seguro Popular de Salud de México].

    Science.gov (United States)

    Garrido-Latorre, Francisco; Hernández-Llamas, Héctor; Gómez-Dantés, Octavio

    2008-01-01

    Measure and compare the percentage of prescriptions fully dispensed to persons with and without Popular Health Insurance (SPS in Spanish) who use ambulatory and general hospital services associated with the Mexico State Health Services (SESA in Spanish), and taking into account insurance status. SESA user satisfaction was also measured with respect to access to medication. Information for the study was taken from four surveys of SESA ambulatory and hospital units that included probabilistic samples with state representativity. Samples of ambulatory units were selected by stratification according to level of care and association to the SPS service network. The findings indicate that the percentage of prescriptions fully dispensed in SESA ambulatory units has improved, reaching approximately 90%, especially among those units offering services to persons affiliated with SPS. Nevertheless, these percentages continue to be lower than those of ambulatory units associated with social security institutions. Percentages of prescriptions fully dispensed have also improved in SESA hospital units, but continue to be relatively low. In nearly all states, as the percentage of prescriptions fully dispensed has increased, user satisfaction with access to medication has also improved. In 2006 more than 50% of the states had high levels of fully dispensed prescriptions among persons with SPS (> or =90%). The more significant problem exists among hospitals, since only 44% of users who received a prescription in SESA hospitals in 2006 had their prescriptions fully dispensed. This finding requires a review of SPS medication policies, which have favored highly prescribed low-cost medications at ambulatory services at the expense of higher cost and more therapeutically effective medications for hospital care, the latter having a greater impact on household budgets.

  6. Distance traveled and frequency of interstate opioid dispensing in opioid shoppers and nonshoppers.

    Science.gov (United States)

    Cepeda, M Soledad; Fife, Daniel; Yuan, Yingli; Mastrogiovanni, Greg

    2013-10-01

    Little is known about how far opioid shoppers travel or how often they cross state lines to fill their opioid prescriptions. This retrospective cohort study evaluated these measures for opioid shoppers and nonshoppers using a large U.S. prescription database. Patients with ≥3 opioid dispensings were followed for 18 months. A subject was considered a shopper when he or she filled overlapping opioid prescriptions written by >1 prescriber at ≥3 pharmacies. A heavy shopper had ≥5 shopping episodes. Outcomes assessed were distance traveled among pharmacies and number of states visited to fill opioid prescriptions. A total of 10,910,451 subjects were included; .7% developed any shopping behavior and their prescriptions accounted for 8.6% of all opioid dispensings. Shoppers and heavy shoppers were younger than the nonshoppers. Shoppers traveled a median of 83.8 miles, heavy shoppers 199.5 miles, and nonshoppers 0 miles. Almost 20% of shoppers or heavy shoppers, but only 4% of nonshoppers, visited >1 state. Shoppers traveled greater distances and more often crossed state borders to fill opioid prescriptions than nonshoppers, and their dispensings accounted for a disproportionate number of opioid dispensings. Sharing of data among prescription-monitoring programs will likely strengthen those programs and may decrease shopping behavior. This study shows that opioid shoppers travel greater distances and more often cross state borders to fill opioid prescriptions than nonshoppers, and their dispensings accounted for a disproportionate number of opioid dispensings. The findings support the need for data sharing among prescription-monitoring programs to deter opioid shopping behavior. Copyright © 2013 American Pain Society. Published by Elsevier Inc. All rights reserved.

  7. How can pharmacist remuneration systems in Europe contribute to generic medicine dispensing?

    Directory of Open Access Journals (Sweden)

    Dylst P

    2012-03-01

    Full Text Available Generic medicines can generate larger savings to health care budgets when their use is supported by incentives on both the supply-side and the demand-side. Pharmacists’ remuneration is one factor influencing the dispensing of generic medicines.Objective: The aim of this article is to provide an overview of different pharmacist remuneration systems for generic medicines in Europe, with a view to exploring how pharmacist remuneration systems can contribute to generic medicine dispensing.Methods: Data were obtained from a literature review, a Master thesis in Pharmaceutical Care at the Catholic University of Leuven and a mailing sent to all members of the Pharmaceutical Group of the European Union with a request for information about the local remuneration systems of community pharmacists and the possible existence of reports on discounting practices.Results: Pharmacists remuneration in most European countries consists of the combination of a fixed fee per item and a certain percentage of the acquisition cost or the delivery price of the medicines. This percentage component can be fixed, regressive or capped for very high-cost medicines and acts as a disincentive for dispensing generic medicines. Discounting for generic medicines is common practice in several European countries but information on this practice tends to be confidential. Nevertheless, data for Belgium, France, the Netherlands and United Kingdom indicated that discounting percentages varied from 10% to 70% of the wholesale selling price.Conclusion: Pharmacists can play an important role in the development of a generic medicines market. Pharmacists should not be financially penalized for dispensing generic medicines. Therefore, their remuneration should move towards a fee-for-performance remuneration instead of a price-dependent reimbursement which is currently used in many European countries. Such a fee-for-performance remuneration system provides a stimulus for generic medicines

  8. An automated swimming respirometer

    DEFF Research Database (Denmark)

    STEFFENSEN, JF; JOHANSEN, K; BUSHNELL, PG

    1984-01-01

    An automated respirometer is described that can be used for computerized respirometry of trout and sharks.......An automated respirometer is described that can be used for computerized respirometry of trout and sharks....

  9. Autonomy and Automation

    Science.gov (United States)

    Shively, Jay

    2017-01-01

    A significant level of debate and confusion has surrounded the meaning of the terms autonomy and automation. Automation is a multi-dimensional concept, and we propose that Remotely Piloted Aircraft Systems (RPAS) automation should be described with reference to the specific system and task that has been automated, the context in which the automation functions, and other relevant dimensions. In this paper, we present definitions of automation, pilot in the loop, pilot on the loop and pilot out of the loop. We further propose that in future, the International Civil Aviation Organization (ICAO) RPAS Panel avoids the use of the terms autonomy and autonomous when referring to automated systems on board RPA. Work Group 7 proposes to develop, in consultation with other workgroups, a taxonomy of Levels of Automation for RPAS.

  10. Configuration Management Automation (CMA) -

    Data.gov (United States)

    Department of Transportation — Configuration Management Automation (CMA) will provide an automated, integrated enterprise solution to support CM of FAA NAS and Non-NAS assets and investments. CMA...

  11. How much do Blantyre dispensers in hospital and community ...

    African Journals Online (AJOL)

    However, as many as 90.9% of the interviewed participants could not mention any possible five or more side-effects of LA and only 13.6% knew how to properly manage the possible effects. Only 27.3% knew the correct dose regimen of LA and none of them knew the condition of taking LA with a fatty meal for improved ...

  12. Intra-individual diagnostic image quality and organ-specific-radiation dose comparison between spiral cCT with iterative image reconstruction and z-axis automated tube current modulation and sequential cCT

    Directory of Open Access Journals (Sweden)

    Holger Wenz

    2016-01-01

    Conclusions: Spiral cCT combined with ATCM and IR allows for significant-radiation dose reduction including a reduce eye lens organ-dose when compared to a tilted sequential cCT while improving subjective and objective image quality.

  13. The impact of automation on pharmacy staff experience of workplace stressors.

    Science.gov (United States)

    James, K Lynette; Barlow, Dave; Bithell, Anne; Hiom, Sarah; Lord, Sue; Oakley, Pat; Pollard, Mike; Roberts, Dave; Way, Cheryl; Whittlesea, Cate

    2013-04-01

    Determine the effect of installing an original pack automated dispensing system (ADS) on staff experience of occupational stressors. Pharmacy staff in a National Health Service hospital in Wales, UK, were administered an anonymous occupational stressor questionnaire pre- (n = 45) and post-automation (n = 32). Survey responses pre- and post-automation were compared using Mann-Whitney U test. Statistical significance was P ≤ 0.05. Four focus groups were conducted (two groups of accredited checking technicians (ACTs) (group 1: n = 4; group 2: n = 6), one group of pharmacists (n = 17), and one group of technicians (n = 4) post-automation to explore staff experiences of occupational stressors. Focus group transcripts were analysed according to framework analysis. Survey response rate pre-automation was 78% (n = 35) and 49% (n = 16) post-automation. Automation had a positive impact on staff experience of stress (P = 0.023), illogical workload allocation (P = 0.004) and work-life balance (P = 0.05). All focus-group participants reported that automation had created a spacious working environment. Pharmacists and ACTs reported that automation had enabled the expansion of their roles. Technicians felt like 'production-line workers.' Robot malfunction was a source of stress. The findings suggest that automation had a positive impact on staff experience of stressors, improving working conditions and workload. Technicians reported that ADS devalued their skills. When installing ADS, pharmacy managers must consider the impact of automation on staff. Strategies to reduce stressors associated with automation include rotating staff activities and role expansions. © 2012 The Authors. IJPP © 2012 Royal Pharmaceutical Society.

  14. 40 CFR Table 1 to Subpart Cccccc... - Applicability Criteria and Management Practices for Gasoline Dispensing Facilities With Monthly...

    Science.gov (United States)

    2010-07-01

    ... Criteria and Management Practices for Gasoline Dispensing Facilities With Monthly Throughput of 100,000... 40 Protection of Environment 14 2010-07-01 2010-07-01 false Applicability Criteria and Management Practices for Gasoline Dispensing Facilities With Monthly Throughput of 100,000 Gallons of Gasoline or More...

  15. Automation in Clinical Microbiology

    Science.gov (United States)

    Ledeboer, Nathan A.

    2013-01-01

    Historically, the trend toward automation in clinical pathology laboratories has largely bypassed the clinical microbiology laboratory. In this article, we review the historical impediments to automation in the microbiology laboratory and offer insight into the reasons why we believe that we are on the cusp of a dramatic change that will sweep a wave of automation into clinical microbiology laboratories. We review the currently available specimen-processing instruments as well as the total laboratory automation solutions. Lastly, we outline the types of studies that will need to be performed to fully assess the benefits of automation in microbiology laboratories. PMID:23515547

  16. Aspects of Chemical Composition and Somatic Cell count of Cow Milk Marketed at Dispensers

    Directory of Open Access Journals (Sweden)

    Mircea Valentin MUNTEAN

    2018-05-01

    Full Text Available Milk quality is influenced by many factors: lactation, fat, protein, lactose, number of somatic cells. In order to process raw milk and compare with criteria of quality and food safety the Regulation of European Parliament and the council no. 853/2004. Analysing the total number of somatic cells (SCC in the period July-August 2017 it is noted that in case of samples collected from first automatic milk dispenser exceed 2 times the maximum admissible values and the samples collected from second automatic milk dispenser are up to the maximum allowable values which show that milking hygiene and animal health are at the European standards required. Analysis of fat content for both cases indicates that it is within the standard values for cow's milk and fat variations for DM1 samples are very low at temperatures above 30 degrees Celsius which shows that high temperatures do not influence these parameters. The biological material study was represented analysed by 30 samples of milk from only two cow milk dispensers functional located in this period in Cluj-Napoca city. These samples were collected at the same time period during July-August months. The aim of present study is to determine whether milk marketed through dispensers under the high temperature conditions specific to this period is affected in terms of qualitative parameter analysis.

  17. The knowledge of emergency contraception and dispensing practices of Patent Medicine Vendors in South West Nigeria.

    Science.gov (United States)

    Fayemi, Mojisola M; Oduola, Olufemi L; Ogbuji, Queen C; Osinowo, Kehinde A; Oyewo, Adejoke E; Osiberu, Olabimpe M

    2010-09-01

    Patent Medicine Vendors (PMVs) can play a critical role in increasing access to emergency contraceptive pills (ECPs) in developing countries, but few studies have examined their knowledge and dispensing practices. Using cluster sampling, the authors selected and interviewed 97 PMVs (60.8 per cent female) in Oyo and Ogun States of Nigeria to assess their knowledge, dispensing practices, and referral for ECPs. About one-third (27.8 per cent) of respondents were not aware of ECPs, and only half knew that ECPs could prevent pregnancy. Forty per cent had ever dispensed ECPs. Reasons proffered by those who do not dispense ECPs included barriers from the State Ministry of Health, police, other regulatory agencies, and religious beliefs. Only 50.5 per cent have referral arrangements for clients. Strategies to increase access to ECPs through PMVs include training on counseling techniques and referral, effective government regulation, and community involvement. Where unsafe abortion is a major cause of maternal mortality, these strategies offer protection for many women in the future.

  18. Validation of a proxy for estrogen receptor status in breast cancer patients using dispensing data.

    Science.gov (United States)

    Srasuebkul, Preeyaporn; Dobbins, Timothy A; Pearson, Sallie-Anne

    2014-06-01

    To assess the performance of a proxy for estrogen receptor (ER) status in breast cancer patients using dispensing data. We derived our proxy using 167 patients. ER+ patients had evidence of at least one dispensing record for hormone therapy during the lookback period, irrespective of diagnosis date and ER- had no dispensing records for hormone therapy during the period. We validated the proxy against our gold standard, ER status from pathology reports or medical records. We assessed the proxy's performance using three lookback periods: 4.5 years, 2 years, 1 year. More than half of our cohort (62%) were >50 years, 54% had stage III/IV breast cancer at recruitment, (46%) were diagnosed with breast cancer in 2009 and 23% were diagnosed before 2006. Sensitivity and specificity were high for the 4.5 year lookback period (93%, 95% CI: 86-96%; and 95%: 83-99%), respectively) and remained high for the 2-year lookback period (91%: 84-95%; and 95%: 83-99%). Sensitivity decreased (83%: 75.2-89%) but specificity remained high (95%: 83-99%) using the 1-year lookback period and the period is long enough to allow sufficient time for hormone therapy to be dispensed. Our proxy accurately infers ER status in studies of breast cancer treatment based on secondary health data. The proxy is most robust with a minimum lookback period of 2 years. © 2012 Wiley Publishing Asia Pty Ltd.

  19. Efficacy of a Feed Dispenser for Horses in Decreasing Cribbing Behaviour

    Directory of Open Access Journals (Sweden)

    Silvia Mazzola

    2016-01-01

    Full Text Available Cribbing is an oral stereotypy, tends to develop in captive animals as a means to cope with stress, and may be indicative of reduced welfare. Highly energetic diets ingested in a short time are one of the most relevant risk factors for the development of cribbing. The aim of this study was to verify whether feeding cribbing horses through a dispenser that delivers small quantities of concentrate when activated by the animal decreases cribbing behaviour, modifies feeding behaviour, or induces frustration. Ten horses (mean age 14 y, balanced for sex, breed, and size (mean height 162 cm, were divided into two groups of 5 horses each: Cribbing and Control. Animals were trained to use the dispenser and videorecorded continuously for 15 consecutive days from 1 h prior to feeding to 2 h after feeding in order to measure their behaviours. The feed dispenser, Quaryka®, induced an increase in time necessary to finish the ration in both groups of horses (P<0.05. With Quaryka, cribbers showed a significant reduction of time spent cribbing (P<0.05. After removal of the feed dispenser (Post-Quaryka, cribbing behaviour significantly increased. The use of Quaryka may be particularly beneficial in horses fed high-energy diets and ingesting the food too quickly.

  20. Microbiological quality of drinking water from dispensers in roadside restaurants of Bangladesh.

    Science.gov (United States)

    Moniruzzaman, M; Akter, S; Islam, M A; Mia, Z

    2011-01-15

    The microbiological status of water from dispensers in different roadside restaurants of Dhaka city and Savar area was analyzed in this study. Seven samples from Dhaka and 8 samples of Savar were checked. The heterotrophic plate count was in a range of 1.0 x 10(3) CFU mL(-1) to 2.0 x 10(4) CFU mL(-1) (from new bottles), 1.0 x 10(3) to 1.5 x 10(4) CFU mL(-1) (after dispensation), and 1.5 x 10(3) CFU mL(-1) to 1.0 x l0(5) CFU mL(-1) (from serving glass). In several of the samples, the heterotrophic plate count was higher than the count in water from new bottle or after dispensation, suggesting added contamination from the serving glass. 80% of the samples were contaminated with total and fecal coliform bacteria, which render these waters unacceptable for human consumption. The samples were found to contain gram negative bacteria like E coli, Shigella sp., Klebsiella sp., Enterobacter sp., Pseudomonas sp., and Salmonella sp., which are potential pathogens and thus pose a serious threat to public health. This study elucidates the importance of monitoring the bottling companies and the restaurants and put them under strict regulations to prevent future outbreak of any water borne diseases caused by consumption of dispensed water.

  1. PMD: designing a portable medicine dispenser for persons suffering from Alzheimer’s disease

    NARCIS (Netherlands)

    de Beer, Roel C.J.M.; Keijers, R.; Shahid, S.; Al Mahmud, A.; Mubin, O.

    2010-01-01

    In this paper we present the user-centred design of a medicine dispenser for persons suffering from Alzheimer’s disease. The prototype was evaluated in two phases with two caregivers and two Alzheimer’s patients. Caregivers evaluated the device positively. The Alzheimer’s patients faced usability

  2. Correlation of emission capability and longevity of dispenser cathodes with characteristics of tungsten powders

    Science.gov (United States)

    Melnikova, Irina P.; Vorozheikin, Victor G.; Usanov, Dmitry A.

    2003-06-01

    The intercorrelation of tungsten powder properties, such as grain size, distribution and morphology, and porous matrix parameters with electron emission capability and longevity of Ba dispenser cathodes are investigated for three different grain morphologies. Best results of tungsten cathode life were found for isoaxis polyhedron morphology in combination with certain powder and matrix parameters.

  3. Correlation of emission capability and longevity of dispenser cathodes with characteristics of tungsten powders

    International Nuclear Information System (INIS)

    Melnikova, Irina P.; Vorozheikin, Victor G.; Usanov, Dmitry A.

    2003-01-01

    The intercorrelation of tungsten powder properties, such as grain size, distribution and morphology, and porous matrix parameters with electron emission capability and longevity of Ba dispenser cathodes are investigated for three different grain morphologies. Best results of tungsten cathode life were found for isoaxis polyhedron morphology in combination with certain powder and matrix parameters

  4. Correlation of emission capability and longevity of dispenser cathodes with characteristics of tungsten powders

    Energy Technology Data Exchange (ETDEWEB)

    Melnikova, Irina P.; Vorozheikin, Victor G.; Usanov, Dmitry A

    2003-06-15

    The intercorrelation of tungsten powder properties, such as grain size, distribution and morphology, and porous matrix parameters with electron emission capability and longevity of Ba dispenser cathodes are investigated for three different grain morphologies. Best results of tungsten cathode life were found for isoaxis polyhedron morphology in combination with certain powder and matrix parameters.

  5. Understanding vs. Competency: The Case of Accuracy Checking Dispensed Medicines in Pharmacy

    Science.gov (United States)

    James, K. Lynette; Davies, J. Graham; Kinchin, Ian; Patel, Jignesh P.; Whittlesea, Cate

    2010-01-01

    Ensuring the competence of healthcare professionals' is core to undergraduate and post-graduate education. Undergraduate pharmacy students and pre-registration graduates are required to demonstrate competence at dispensing and accuracy checking medicines. However, competence differs from understanding. This study determined the competence and…

  6. Exceptional circumstance drug dispensing: history and expenditures of the Brazilian Ministry of Health.

    Science.gov (United States)

    Carias, Claudia Mezleveckas; Vieira, Fabíola Sulpino; Giordano, Carlos V; Zucchi, Paola

    2011-04-01

    To describe the technical aspects of the Exceptional Circumstance Drug Dispensing Program of the Brazilian Ministry of Health, especially with respect to the cost of dispensed medication. Technical information was obtained from the ordinances that regulate the Program. Expenditure from 2000 to 2007 was obtained from the Sistema Único de Saúde's (Unified Healthcare System) Outpatient Information System. All drugs dispensed between 1993 and 2009 and the amount and cost of each procedure were evaluated, based on information from the high-complexity procedure authorization of each of the country's states. The Program changed with the increase in the number of pharmacological agents and presentations distributed by, and the number of diseases contemplated in the program. In 1993, the program distributed 15 pharmacological agents in 31 distinct presentations. This number increased to 109 agents in 243 presentations in 2009. Total Ministry of Health expenditure with medications was R$1,410,181,600.74 in 2007, almost twice the amount spent in 2000, R$684,975,404.43. Diseases whose expenditure increased in the period included chronic renal insufficiency, transplantation, and hepatitis C. The Exceptional Circumstance Drug Dispensing Program is in constant transformation, aimed at building instruments and strategies that can ensure and expand access to medication among the population. Alternatives should be sought to decrease the financial impact of the Program to a level that does not impact other sectors of the health care system, given the high cost associated with novel interventions.

  7. A systematic approach for the location of hand sanitizer dispensers in hospitals.

    Science.gov (United States)

    Cure, Laila; Van Enk, Richard; Tiong, Ewing

    2014-09-01

    Compliance with hand hygiene practices is directly affected by the accessibility and availability of cleaning agents. Nevertheless, the decision of where to locate these dispensers is often not explicitly or fully addressed in the literature. In this paper, we study the problem of selecting the locations to install alcohol-based hand sanitizer dispensers throughout a hospital unit as an indirect approach to maximize compliance with hand hygiene practices. We investigate the relevant criteria in selecting dispenser locations that promote hand hygiene compliance, propose metrics for the evaluation of various location configurations, and formulate a dispenser location optimization model that systematically incorporates such criteria. A complete methodology to collect data and obtain the model parameters is described. We illustrate the proposed approach using data from a general care unit at a collaborating hospital. A cost analysis was performed to study the trade-offs between usability and cost. The proposed methodology can help in evaluating the current location configuration, determining the need for change, and establishing the best possible configuration. It can be adapted to incorporate alternative metrics, tailored to different institutions and updated as needed with new internal policies or safety regulation.

  8. An Automated Motion Detection and Reward System for Animal Training.

    Science.gov (United States)

    Miller, Brad; Lim, Audrey N; Heidbreder, Arnold F; Black, Kevin J

    2015-12-04

    A variety of approaches has been used to minimize head movement during functional brain imaging studies in awake laboratory animals. Many laboratories expend substantial effort and time training animals to remain essentially motionless during such studies. We could not locate an "off-the-shelf" automated training system that suited our needs.  We developed a time- and labor-saving automated system to train animals to hold still for extended periods of time. The system uses a personal computer and modest external hardware to provide stimulus cues, monitor movement using commercial video surveillance components, and dispense rewards. A custom computer program automatically increases the motionless duration required for rewards based on performance during the training session but allows changes during sessions. This system was used to train cynomolgus monkeys (Macaca fascicularis) for awake neuroimaging studies using positron emission tomography (PET) and functional magnetic resonance imaging (fMRI). The automated system saved the trainer substantial time, presented stimuli and rewards in a highly consistent manner, and automatically documented training sessions. We have limited data to prove the training system's success, drawn from the automated records during training sessions, but we believe others may find it useful. The system can be adapted to a range of behavioral training/recording activities for research or commercial applications, and the software is freely available for non-commercial use.

  9. Surface contamination of counting tools after mock dispensing of cyclophosphamide in a simulated outpatient pharmacy.

    Science.gov (United States)

    Chaffee, Bruce W; Lander, Michael J; Christen, Catherine; Redic, Kimberly A

    2018-01-01

    Purpose The primary aim was to determine if dispensing of cyclophosphamide tablets resulted in accumulated residue on pharmacy counting tools during a simulated outpatient dispensing process. Secondary objectives included determining if cyclophosphamide contamination exceeded a defined threshold level of 1 ng/cm 2 and if a larger number of prescriptions dispensed resulted in increased contamination. Methods Mock prescriptions of 40 cyclophosphamide 50 mg tablets were counted on clean trays in three scenarios using a simulated outpatient pharmacy after assaying five cleaned trays as controls. The three scenarios consisted of five simulated dispensings of one, three, or six prescriptions dispensed per scenario. Wipe samples of trays and spatulas were collected and assayed for all trays, including the five clean trays used as controls. Contamination was defined as an assayed cyclophosphamide level at or above 0.001 ng/cm 2 and levels above 1 ng/cm 2 were considered sufficient to cause risk of human uptake. Mean contamination for each scenario was calculated and compared using one-way analysis of variance. P-values of contamination on trays used to count one, three, and six cyclophosphamide prescriptions was 0.51 ± 0.10 (p=0.0003), 1.02 ± 0.10 (p contamination. Increasing the number of prescriptions dispensed from 1 to 3, 1 to 6, and 3 to 6 counts increased contamination by 0.51 ± 0.15 (p = 0.0140), 1.31 + 0.15 (p contaminates pharmacy counting tools, and an increased number of prescriptions dispensed correlates with increased level of contamination. Counting out three or more prescriptions leads to trays having contamination that surpasses the threshold at which worker exposure may be increased. Pharmacies should consider devoting a separate tray to cyclophosphamide tablets, as cross-contamination could occur with other drugs and the efficacy of decontamination methods is unclear. Employee exposure could be minimized with the use

  10. Through-Silicon-Via Underfill Dispensing for 3D Die/Interposer Stacking

    Science.gov (United States)

    Le, Fuliang

    The next generation packaging keeps up with the increased demands of functionality by using the third dimension. 3D chip stacking with TSVs has been identified as one of the major technologies to achieve higher silicon density and shorter interconnection. In order to protect solder interconnections from hostile environments and redistribute thermal stress caused by CTE mismatch, underfill should be applied for the under-chip spaces. In this study, TSV underfill dispensing is introduced to address the underfill challenge for 3D chip stacks. The material properties are first measured and the general trend indicates viscosity and contact angle dropping significantly with an increase in temperature, and surface tension falling slightly as the temperature increases. Underfill should assure a complete encapsulation, avoiding excessive filling time that can result in substantial manufacturing delays. Typically, the inflows for TSV underfill can be free droplets or a constant flow rate. For a constant inflow, the underfill flow is driven by pressure difference and the filling time is governed by flow radius, gap clearance and the constant flow rate. For an inflow of free droplets, the underfill flow is driven by capillary action and the filling time is related to viscosity, flow radius, gap clearance, surface tension, contact angle and TSV size. In general, TSV underfill dispensing with a constant inflow has much shorter filling time than dispensing with an inflow of free droplets. TSV underfill dispensing on a 3D chip stack may induce the risk of an edge flood failure. In order to avoid an edge flood, fluid pressure around the sidewalls of a 3D chip stack cannot exceed limit equilibrium pressure. For TSV dispensing with free droplets, there is no risk of forming an edge flood. However, for a constant inflow, TSV dispensing should be carefully controlled to avoid excessive pressure. Besides, it is suggested that the TSVs in stacked chips be aligned in the vertical

  11. Isolation of Raoultella planticola from refillable antimicrobial liquid soap dispensers in a dental setting.

    Science.gov (United States)

    Momeni, Stephanie S; Tomlin, Nancy; Ruby, John D

    2015-04-01

    Liquid antimicrobial soaps are commonly used in the dental health care setting for hand washing to minimize the potential spread of infectious agents to health care workers and patients. The purpose of the current study was to evaluate possible bacterial contamination of antimicrobial liquid soap dispensers located in 2 institutional comprehensive dental care clinics. Fourteen soap dispensers and 16 original stock containers were sampled. A 1-milliliter aliquot was diluted in 10 mL of phosphate buffer (Tween-80; Acros). Serial dilutions were plated in duplicate on neutralizing agar and incubated for 7 days. Molecular identification was performed using 500 base pair comparisons of 16S ribosomal ribonucleic acid sequencing. Taq polymerase chain reaction was performed with sequence-specific primers for Raoultella species. Bacterial growth was observed at 18 hours for 57% (8 of 14) of soap dispenser samples. Bacterial densities ranged from 4 × 10(2) to 6 × 10(9) colony-forming units per milliliter. Original commercial containers exhibited no growth. Isolates were identified as Raoultella (Klebsiella) planticola. This is the first study to the authors' knowledge indicating recovery of R. planticola from antimicrobial liquid soap dispensers. R. planticola is a recognized environmental opportunistic pathogen that potentially poses a health concern. These findings indicate compliance problems with infection prevention recommendations and support the US Centers for Disease Control and Prevention's recommendation that dispensers should not be topped off. High bacterial loads of R. planticola are inconsistent with infection control practices and are a concern because transmission and possible infection to the health care worker or the patient may occur. Copyright © 2015 American Dental Association. Published by Elsevier Inc. All rights reserved.

  12. The expected and unexpected benefits of dispensing the exact number of pills.

    Science.gov (United States)

    Treibich, Carole; Lescher, Sabine; Sagaon-Teyssier, Luis; Ventelou, Bruno

    2017-01-01

    From November 2014 to November 2015, an experiment in French community pharmacies replaced traditional pre-packed boxes by per-unit dispensing of pills in the exact numbers prescribed, for 14 antibiotics. A cluster randomised control trial was carried out in 100 pharmacies. 75 pharmacies counted out the medication by units (experimental group), the other 25 providing the treatment in the existing pharmaceutical company boxes (control group). Data on patients under the two arms were compared to assess the environmental, economic and health effects of this change in drug dispensing. In particular, adherence was measured indirectly by comparing the number of pills left at the end of the prescribed treatment. Out of the 1185 patients included during 3 sessions of 4 consecutive weeks each, 907 patients experimented the personalized delivery and 278 were assigned to the control group, consistent with a 1/3 randomization-rate at the pharmacy level. 80% of eligible patients approved of the per-unit dispensing of their treatment. The initial packaging of the drugs did not match with the prescription in 60% of cases and per-unit dispensing reduced by 10% the number of pills supplied. 13.1% of patients declared that they threw away pills residuals instead of recycling-no differences between groups. Finally, per-unit dispensing appeared to improve adherence to antibiotic treatment (marginal effect 0.21, IC 95, 0.14-0.28). Supplying antibiotics per unit is not only beneficial in terms of a reduced number of pills to reimburse or for the environment (less pills wasted and non-recycled), but also has a positive and unexpected impact on adherence to treatment, and thus on both individual and public health.

  13. Alternative Manufacturing Concepts for Solid Oral Dosage Forms From Drug Nanosuspensions Using Fluid Dispensing and Forced Drying Technology.

    Science.gov (United States)

    Bonhoeffer, Bastian; Kwade, Arno; Juhnke, Michael

    2018-03-01

    Flexible manufacturing technologies for solid oral dosage forms with a continuous adjustability of the manufactured dose strength are of interest for applications in personalized medicine. This study explored the feasibility of using microvalve technology for the manufacturing of different solid oral dosage form concepts. Hard gelatin capsules filled with excipients, placebo tablets, and polymer films, placed in hard gelatin capsules after drying, were considered as substrates. For each concept, a basic understanding of relevant formulation parameters and their impact on dissolution behavior has been established. Suitable matrix formers, present either on the substrate or directly in the drug nanosuspension, proved to be essential to prevent nanoparticle agglomeration of the drug nanoparticles and to ensure a fast dissolution behavior. Furthermore, convection and radiation drying methods were investigated for the fast drying of drug nanosuspensions dispensed onto polymer films, which were then placed in hard gelatin capsules. Changes in morphology and in drug and matrix former distribution were observed for increasing drying intensity. However, even fast drying times below 1 min could be realized, while maintaining the nanoparticulate drug structure and a good dissolution behavior. Copyright © 2018 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  14. Radiation dose monitoring in the clinical routine

    Energy Technology Data Exchange (ETDEWEB)

    Guberina, Nika [UK Essen (Germany). Radiology

    2017-04-15

    Here we describe the first clinical experiences regarding the use of an automated radiation dose management software to monitor the radiation dose of patients during routine examinations. Many software solutions for monitoring radiation dose have emerged in the last decade. The continuous progress in radiological techniques, new scan features, scanner generations and protocols are the primary challenge for radiation dose monitoring software systems. To simulate valid dose calculations, radiation dose monitoring systems have to follow current trends and stay constantly up-to-date. The dose management software is connected to all devices at our institute and conducts automatic data acquisition and radiation dose calculation. The system incorporates 18 virtual phantoms based on the Cristy phantom family, estimating doses in newborns to adults. Dose calculation relies on a Monte Carlo simulation engine. Our first practical experiences demonstrate that the software is capable of dose estimation in the clinical routine. Its implementation and use have some limitations that can be overcome. The software is promising and allows assessment of radiation doses, like organ and effective doses according to ICRP 60 and ICRP 103, patient radiation dose history and cumulative radiation doses. Furthermore, we are able to determine local diagnostic reference doses. The radiation dose monitoring software systems can facilitate networking between hospitals and radiological departments, thus refining radiation doses and implementing reference doses at substantially lower levels.

  15. Reformulation of controlled-release oxycodone and pharmacy dispensing patterns near the US-Canada border.

    Science.gov (United States)

    Gomes, Tara; Paterson, J Michael; Juurlink, David N; Dhalla, Irfan A; Mamdani, Muhammad M

    2012-01-01

    In August 2010, a tamper-resistant formulation of controlled-release oxycodone (OxyContin-OP) was introduced in the United States but not in Canada. Our objective was to determine whether introduction of OxyContin-OP in the United States influenced prescription volumes for the original controlled-release oxycodone formulation (OxyContin) at Canadian pharmacies near the international border. We conducted a population-based, serial, cross-sectional study of prescriptions dispensed from pharmacies in the 3 cities with the highest volume of US-Canada border crossings in Ontario: Niagara Falls, Windsor and Sarnia. We analyzed data on all outpatient prescriptions for OxyContin dispensed by Canadian pharmacies near each border crossing between 2010 Apr. 1 and 2012 Feb. 29. We calculated and compared monthly prescription rates, adjusted per 1000 population and stratified by tablet strength. The number of tablets dispensed near 4 border crossings in the 3 Canadian cities remained stable over the study period. However, the rate of dispensing at pharmacies near the Detroit-Windsor Tunnel increased roughly 4-fold between August 2010 and February 2011, from 505 to 1969 tablets per 1000 population. By April 2011, following warnings to prescribers and pharmacies regarding drug-seeking behaviour, the dispensing rate declined to 1683 tablets per 1000 population in this area. By November 2011, the rate had returned to levels observed in early 2010. Our analyses suggest that 242 075 excess OxyContin tablets were dispensed near the Detroit-Windsor Tunnel between August 2010 and October 2011. Prescribing of the original formulation of controlled-release oxycodone rose substantially near a major international border crossing following the introduction of a tamper-resistant formulation in the United States. It is possible that the restriction of this finding to the area surrounding the Detroit-Windsor Tunnel reflects specific characteristics of this border crossing, including its high

  16. Identification of risks associated with the prescribing and dispensing of oral anticancer medicines in Ireland.

    LENUS (Irish Health Repository)

    Hammond, Lisa

    2012-09-09

    Background Oral anticancer medicines (OAM) facilitate transfer of cancer care into the community, where safeguards developed in hospitals that control their prescribing, dispensing and administration may not exist. Objective To determine if the systems of prescribing and dispensing OAM in Ireland facilitate clinical verification of the prescription, thereby ensuring treatment is tailored and appropriate for the patient. Setting Randomly selected community pharmacies in Ireland and all Irish hospitals with cancer services. Method A questionnaire was sent to a random selection of Irish community pharmacists. A different questionnaire was sent to all Irish hospitals treating cancer patients. One hundred OAM prescriptions were retrospectively reviewed, to assess the information presented and the potential barriers to a community pharmacist performing a clinical verification of the prescription. Main outcome measure Community pharmacist survey: problems experienced when dispensing OAM and risk factors identified with the current system. Hospital pharmacist survey: proportion of hospitals that clinically verify prescriptions for parenteral versus oral anticancer medicines and associated policies. OAM prescription review: proportion of OAM prescriptions that contained sufficient information for a community pharmacist to clinically verify the prescription and safely dispense the medication. Results Sixty-four percent of community pharmacist respondents felt they did not have enough information available to them to safely dispense these prescriptions, and 74 % felt that patients are at risk with the current Irish system of prescribing and dispensing OAM. Irish hospitals do not have systems to ensure that all OAM prescriptions are clinically verified by a pharmacist. Seventeen different agents were prescribed on the prescriptions reviewed. The information provided to the community pharmacist would have allowed them to clinically verify 7 % of the OAM prescriptions

  17. Laboratory Automation and Middleware.

    Science.gov (United States)

    Riben, Michael

    2015-06-01

    The practice of surgical pathology is under constant pressure to deliver the highest quality of service, reduce errors, increase throughput, and decrease turnaround time while at the same time dealing with an aging workforce, increasing financial constraints, and economic uncertainty. Although not able to implement total laboratory automation, great progress continues to be made in workstation automation in all areas of the pathology laboratory. This report highlights the benefits and challenges of pathology automation, reviews middleware and its use to facilitate automation, and reviews the progress so far in the anatomic pathology laboratory. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Automated cloning methods.; TOPICAL

    International Nuclear Information System (INIS)

    Collart, F.

    2001-01-01

    Argonne has developed a series of automated protocols to generate bacterial expression clones by using a robotic system designed to be used in procedures associated with molecular biology. The system provides plate storage, temperature control from 4 to 37 C at various locations, and Biomek and Multimek pipetting stations. The automated system consists of a robot that transports sources from the active station on the automation system. Protocols for the automated generation of bacterial expression clones can be grouped into three categories (Figure 1). Fragment generation protocols are initiated on day one of the expression cloning procedure and encompass those protocols involved in generating purified coding region (PCR)

  19. Complacency and Automation Bias in the Use of Imperfect Automation.

    Science.gov (United States)

    Wickens, Christopher D; Clegg, Benjamin A; Vieane, Alex Z; Sebok, Angelia L

    2015-08-01

    We examine the effects of two different kinds of decision-aiding automation errors on human-automation interaction (HAI), occurring at the first failure following repeated exposure to correctly functioning automation. The two errors are incorrect advice, triggering the automation bias, and missing advice, reflecting complacency. Contrasts between analogous automation errors in alerting systems, rather than decision aiding, have revealed that alerting false alarms are more problematic to HAI than alerting misses are. Prior research in decision aiding, although contrasting the two aiding errors (incorrect vs. missing), has confounded error expectancy. Participants performed an environmental process control simulation with and without decision aiding. For those with the aid, automation dependence was created through several trials of perfect aiding performance, and an unexpected automation error was then imposed in which automation was either gone (one group) or wrong (a second group). A control group received no automation support. The correct aid supported faster and more accurate diagnosis and lower workload. The aid failure degraded all three variables, but "automation wrong" had a much greater effect on accuracy, reflecting the automation bias, than did "automation gone," reflecting the impact of complacency. Some complacency was manifested for automation gone, by a longer latency and more modest reduction in accuracy. Automation wrong, creating the automation bias, appears to be a more problematic form of automation error than automation gone, reflecting complacency. Decision-aiding automation should indicate its lower degree of confidence in uncertain environments to avoid the automation bias. © 2015, Human Factors and Ergonomics Society.

  20. A Prospective Randomized Trial on the Effect of Using an Electronic Monitoring Drug Dispensing Device to Improve Adherence and Compliance.

    Science.gov (United States)

    Henriksson, Jarmo; Tydén, Gunnar; Höijer, Jonas; Wadström, Jonas

    2016-01-01

    Outcome after renal transplantation depends on patient compliance and adherence for early detection of complications and identification of intervention opportunities. Compliance describes the degree to which patients follow medical advice and take their medications. Adherence has been defined as the extent to which a patients' behavior coincides with clinical prescriptions. Patients were randomized 7 to 14 days after transplantation into groups with (n = 40) and without (n = 40) an electronic medication dispenser (EMD). The EMD, which was used for the 1-year study period, recorded the date and time the patient took their medications and was monitored via a web-based application. Patients were monitored for 1 year regarding outpatient follow-up visits, emergency hospitalizations, renal biopsies, rejection episodes, renal function, and blood concentration of medications. Compliance in the intervention group was 97.8% (the control group was not assessed). Number of missed doses varied significantly by weekday (P = 0.033); patients were most likely to miss doses on Saturdays and Thursdays. Patients missed a total of 11 follow-up visits. During the study, 92 biopsies were performed on 55 patients (intervention group: 32 [17]; control group, 60 [38]). Biopsy-verified rejection was three times more common among controls (13 patients vs. 4; P = 0.054, not significant). Average P-creatinine level was slightly lower in the intervention group than the control group (131 vs. 150 μmol/L, not significant), whereas mean tacrolimus was similar (7.32 vs. 7.22 ng/mL, n.s.). The EMD is associated with high compliance, and there are also indications of a lower rejection rate.

  1. Flow Channel Influence of a Collision-Based Piezoelectric Jetting Dispenser on Jet Performance

    Directory of Open Access Journals (Sweden)

    Can Zhou

    2018-04-01

    Full Text Available To improve the jet performance of a bi-piezoelectric jet dispenser, mathematical and simulation models were established according to the operating principle. In order to improve the accuracy and reliability of the simulation calculation, a viscosity model of the fluid was fitted to a fifth-order function with shear rate based on rheological test data, and the needle displacement model was fitted to a nine-order function with time based on real-time displacement test data. The results show that jet performance is related to the diameter of the nozzle outlet and the cone angle of the nozzle, and the impacts of the flow channel structure were confirmed. The approach of numerical simulation is confirmed by the testing results of droplet volume. It will provide a reliable simulation platform for mechanical collision-based jet dispensing and a theoretical basis for micro jet valve design and improvement.

  2. Integration of dispenser-printed ultra-low-voltage thermoelectric and energy storage devices

    International Nuclear Information System (INIS)

    Wang, Z; Chen, A; Winslow, R; Madan, D; Nill, M; Wright, P K; Juang, R C; Evans, J W

    2012-01-01

    This paper reports on an integrated energy harvesting prototype that consists of dispenser-printed thermoelectric energy harvesting and electrochemical energy storage devices. Parallel-connected thermoelectric devices with low internal resistances were designed, fabricated and characterized. The use of a commercially available dc-to-dc converter was explored to step-up a 27.1 mV input voltage from a printed thermoelectric device to a regulated 2.34 V output at a maximum of 34% conversion efficiency. The regulated power succeeds in charging dispenser-printed, zinc-based micro-batteries with charging efficiencies of up to 67%. The prototype presented in this work demonstrates the feasibility of deploying a printable, cost-effective and perpetual power solution for practical wireless sensor network applications. (paper)

  3. Development of alloy-film coated dispenser cathode for terahertz vacuum electron devices application

    International Nuclear Information System (INIS)

    Barik, R.K.; Bera, A.; Raju, R.S.; Tanwar, A.K.; Baek, I.K.; Min, S.H.; Kwon, O.J.; Sattorov, M.A.; Lee, K.W.; Park, G.-S.

    2013-01-01

    High power terahertz vacuum electron devices demand high current density and uniform emission dispenser cathode. It was found that the coating of noble metals e.g., Os, Ir, and Re on the surface of tungsten dispenser cathodes enhances the emission capabilities and uniformity. Hence metal coated cathode might be the best candidate for terahertz devices applications. In this study, ternary-alloy-film cathode (2Os:2Re:1 W) and Os coated cathode have been developed and the results are presented. The cathodes made out of this alloy coating showed 1.5 times higher emission and 0.02 eV emission uniformity as compared to those of simply Os coated cathodes which can be used in terahertz devices application.

  4. Development of alloy-film coated dispenser cathode for terahertz vacuum electron devices application

    Energy Technology Data Exchange (ETDEWEB)

    Barik, R. K.; Bera, A. [School of Electrical Engineering and Computer Science, Seoul National University, Seoul (Korea, Republic of); Raju, R. S. [Central Electronics Engineering Research Institute (CEERI), Rajasthan (India); Tanwar, A. K.; Baek, I. K.; Min, S. H.; Kwon, O. J.; Sattorov, M. A. [Department of Physics and Astronomy, Center for THz-Bio Application Systems, and Seoul-Teracom Inc., Seoul National University, Seoul (Korea, Republic of); Lee, K. W. [LIG Nex1, Seoul (Korea, Republic of); Park, G.-S., E-mail: gunsik@snu.ac.kr [School of Electrical Engineering and Computer Science, Seoul National University, Seoul (Korea, Republic of); Department of Physics and Astronomy, Center for THz-Bio Application Systems, and Seoul-Teracom Inc., Seoul National University, Seoul (Korea, Republic of); Advanced Institute of Convergence Technology, Suwon-si, Gyeonggi-do (Korea, Republic of)

    2013-07-01

    High power terahertz vacuum electron devices demand high current density and uniform emission dispenser cathode. It was found that the coating of noble metals e.g., Os, Ir, and Re on the surface of tungsten dispenser cathodes enhances the emission capabilities and uniformity. Hence metal coated cathode might be the best candidate for terahertz devices applications. In this study, ternary-alloy-film cathode (2Os:2Re:1 W) and Os coated cathode have been developed and the results are presented. The cathodes made out of this alloy coating showed 1.5 times higher emission and 0.02 eV emission uniformity as compared to those of simply Os coated cathodes which can be used in terahertz devices application.

  5. Microfluidic device and method for focusing, segmenting, and dispensing of a fluid stream

    Science.gov (United States)

    Jacobson, Stephen C [Knoxville, TN; Ramsey, J Michael [Knoxville, TN

    2008-09-09

    A microfluidic device and method for forming and dispensing minute volume segments of a material are described. In accordance with the present invention, a microfluidic device and method are provided for spatially confining the material in a focusing element. The device is also adapted for segmenting the confined material into minute volume segments, and dispensing a volume segment to a waste or collection channel. The device further includes means for driving the respective streams of sample and focusing fluids through respective channels into a chamber, such that the focusing fluid streams spatially confine the sample material. The device may also include additional means for driving a minute volume segment of the spatially confined sample material into a collection channel in fluid communication with the waste reservoir.

  6. Emission characteristics of dispenser cathodes with a fine-grained tungsten top layer

    Science.gov (United States)

    Kimura, S.; Higuchi, T.; Ouchi, Y.; Uda, E.; Nakamura, O.; Sudo, T.; Koyama, K.

    1997-02-01

    In order to improve the emission stability of the Ir-coated dispenser cathode under ion bombardment, a fine-grained tungsten top layer was applied on the substrate porous tungsten plug before Ir coating. The emission characteristics were studied after being assembled in a CRT gun. Cathode current was measured under pulse operation in a range of 0.1-9% duty. Remarkable anti-ion bombardment characteristics were observed over the range of 1-6% duty. The improved cathode showed 1.5 times higher emission current than that of a conventional Ir-coated dispenser cathode at 4% duty. AES analysis showed that the recovering rates of surface Ba and O atoms after ion bombardment were 2.5 times higher. From these results it is confirmed that the Ir coated cathode with a fine-grained tungsten top layer is provided with a good tolerance against the ion bombardment.

  7. Accurate, consistent, and fast droplet splitting and dispensing in electrowetting on dielectric digital microfluidics

    Science.gov (United States)

    Nikapitiya, N. Y. Jagath B.; Nahar, Mun Mun; Moon, Hyejin

    2017-12-01

    This letter reports two novel electrode design considerations to satisfy two very important aspects of EWOD operation—(1) Highly consistent volume of generated droplets and (2) Highly improved accuracy in the generated droplet volume. Considering the design principles investigated two novel designs were proposed; L-junction electrode design to offer high throughput droplet generation and Y-junction electrode design to split a droplet very fast while maintaining equal volume of each part. Devices of novel designs were fabricated and tested, and the results are compared with those of conventional approach. It is demonstrated that inaccuracy and inconsistency of droplet volume dispensed in the device with novel electrode designs are as low as 0.17 and 0.10%, respectively, while those of conventional approach are 25 and 0.76%, respectively. The dispensing frequency is enhanced from 4 to 9 Hz by using the novel design.

  8. Validating a proxy for disease progression in metastatic cancer patients using prescribing and dispensing data.

    Science.gov (United States)

    Joshi, Vikram; Adelstein, Barbara-Ann; Schaffer, Andrea; Srasuebkul, Preeyaporn; Dobbins, Timothy; Pearson, Sallie-Anne

    2017-10-01

    Routine data collections are used increasingly to examine outcomes of real-world cancer drug use. These datasets lack clinical details about important endpoints such as disease progression. To validate a proxy for disease progression in metastatic cancer patients using prescribing and dispensing claims. We used data from a cohort study of patients undergoing chemotherapy who provided informed consent to the collection of cancer-treatment data from medical records and linkage to pharmaceutical claims. We derived proxy decision rules based on changes to drug treatment in prescription histories (n = 36 patients) and validated the proxy in prescribing data (n = 62 patients). We adapted the decision rules and validated the proxy in dispensing data (n = 109). Our gold standard was disease progression ascertained in patient medical records. Individual progression episodes were the unit of analysis for sensitivity and Positive Predictive Value (PPV) calculations and specificity and Negative Predictive Value (NPV) were calculated at the patient level. The sensitivity of our proxy in prescribing data was 74.3% (95% Confidence Interval (CI), 55.6-86.6%) and PPV 61.2% (95% CI, 45.0-75.3%); specificity and NPV were 87.8% (95% CI, 73.8-95.9%) and 100% (95% CI, 90.3-100%), respectively. In dispensing data, the sensitivity of our proxy was 64% (95% CI, 55.0-77.0%) and PPV 56.0% (95% CI, 43.0-69.0%); specificity and NPV were 81% (95% CI, 70.05-89.0%) and 91.0% (95% CI, 82.0-97.0%), respectively. Our proxy overestimated episodes of disease progression. The proxy's performance is likely to improve if the date of prescribing is used instead of date of dispensing in claims data and by incorporating medical service claims (such as imaging prior to drug changes) in the algorithm. Our proxy is not sufficiently robust for use in real world comparative effectiveness research for cancer medicines. © 2016 John Wiley & Sons Australia, Ltd.

  9. Care relationships at stake? Home healthcare professionals’ experiences with digital medicine dispensers – a qualitative study

    OpenAIRE

    Nakrem, Sigrid; Solbjør, Marit; Pettersen, Ida Nilstad; Kleiven, Hanne Hestvik

    2018-01-01

    Background Although digital technologies can mitigate the burdens of home healthcare services caused by an ageing population that lives at home longer with complex health problems, research on the impacts and consequences of digitalised remote communication between patients and caregivers is lacking. The present study explores how home healthcare professionals had experienced the introduction of digital medicine dispensers and their influence on patient-caregiver relationships. Methods...

  10. Subsidising patient dispensing fees: the cost of injecting equity into the opioid pharmacotherapy maintenance system.

    Science.gov (United States)

    Chalmers, Jenny; Ritter, Alison

    2012-11-01

    Australian pharmacotherapy maintenance programs incur costs to patients. These dispensing fees represent a financial burden to patients and are inconsistent with Australian health-care principles. No previous work has examined the current costs nor the future predicted costs if government subsidised dispensing fees. A system dynamics model, which simulated the flow of patients into and out of methadone maintenance treatment, was developed. Costs were imputed from existing research data. The approach enabled simulation of possible behavioural responses to a fee subsidy (such as higher retention) and new estimates of costs were derived under such scenarios. Current modelled costs (AUS$11.73m per month) were largely borne by state/territory government (43%), with patients bearing one-third (33%) of the total costs and the Commonwealth one-quarter (24%). Assuming no behavioural changes associated with fee subsidies, the cost of subsidising the dispensing fees of Australian methadone patients would be $3.9m per month. If retention were improved as a result of fee subsidy, treatment numbers would increase and the model estimates an additional cost of $0.8m per month. If this was coupled with greater numbers entering treatment, the costs would increase by a further $0.4m per month. In total, full fee subsidy with modelled behavioural changes would increase per annum government expenditure by $81.8m to $175.8m. If government provided dispensing fee relief for methadone maintenance patients, it would be a costly exercise. However, these additional costs are offset by the social and health gains achieved from the methadone maintenance program. © 2012 Australasian Professional Society on Alcohol and other Drugs.

  11. Concern about the Expanding Prescription Drug Epidemic: A Survey of Licensed Prescribers and Dispensers.

    Science.gov (United States)

    Wright, R Eric; Reed, Nia; Carnes, Neal; Kooreman, Harold E

    2016-01-01

    Prescription drug misuse and abuse has reached epidemic levels in the U.S., and stands as a leading cause of death. As the primary gatekeepers to the medications contributing to this epidemic, it is critical to understand the views of licensed health care professionals. In this study, we examine health care professionals' concern regarding prescription drug abuse in their communities and the impact their concern has had on their prescribing and dispensing practices. An online survey of licensed health care providers. Conducted in Indiana. This study was a state-wide evaluation of Indiana's prescription drug monitoring program. The questionnaire asked respondents how concerned they were about prescription drug abuse in their community. Variation in the level of concern was examined using ordinary least squares regression and information about the respondents' demographic background and clinical experience. In addition, we used logistic regression to examine whether concern was associated with changing prescribing and/or dispensing behavior. The majority of providers indicated they were "moderately" or "extremely concerned" about prescription drug abuse in their communities. The level of concern, however, varied significantly by profession, with pharmacists, physicians, nurse practitioners/physician assistants being more concerned than dentists. Additional analyses indicate that providers with higher levels of concern were those who also reported recently changing their prescribing and/or dispensing behavior. The voluntary nature and geographical focus of the study limits the generalizability of the findings. Concern about prescription drug abuse is generally high across the major health care professions; however, a significant minority of providers, particularly among dentists, expressed little or no concern about the epidemic. Increasing health care providers' general level of concern about prescription drug abuse may be an effective public health tool for

  12. The univocal identification and safe dispensation of medicinal products across Europe – challenges and solution proposal

    Directory of Open Access Journals (Sweden)

    Stroetmann, Karl A.

    2017-12-01

    Full Text Available Problem: The Smart Open Services for European Patients (epSOS the exchange of electronic Patient Summaries and ePrescriptions between selected member states of the European Union (EU. This project basically solved the ‘communication’ or message transfer problem. However, it encountered a serious ‘delivery’ problem: the safe dispensation of a medicinal product noted in a prescription from a given country by a retail pharmacist in another country. The reason for this was that the specified medicine could in many instances not univocally be identified – the same name may identify a product with a different active ingredient, or the product with identical composition may carry a different name in the other country. If the prescribed medicine had not been authorised for marketing in the other country, information on its attributes may not be available. This rendered dispensation by the pharmacist impossible, even where substitution would, in principle, be allowed and possible.Objectives: This paper reports on the goal, activities and achievements of the openMedicine project towards development of a digital solution and its implementation to meet this identification and the resulting delivery challenge. European-wide and cross-Atlantic endeavours to enhance pharmacovigilance by being able to match adverse event reports filed under different drug names which provide, however, for the same active ingredient(s were developed upon. And the need for and benefits of being able to trace for clinical purposes, e.g. the longer-term treatment with the same active ingredient, even when the name of the prescribed medicine changed several times, were explored.Methodological approach: The openMedicine project was funded by the European Commission (EC on behalf of member states to analyse this European-wide problem. Work benefitted from the epSOS project and work by the European Medicines Agency (EMA, the USA Federal Drug Agency (FDA, and standard

  13. Numerical Simulation Analysis of High-precision Dispensing Needles for Solid-liquid Two-phase Grinding

    Science.gov (United States)

    Li, Junye; Hu, Jinglei; Wang, Binyu; Sheng, Liang; Zhang, Xinming

    2018-03-01

    In order to investigate the effect of abrasive flow polishing surface variable diameter pipe parts, with high precision dispensing needles as the research object, the numerical simulation of the process of polishing high precision dispensing needle was carried out. Analysis of different volume fraction conditions, the distribution of the dynamic pressure and the turbulence viscosity of the abrasive flow field in the high precision dispensing needle, through comparative analysis, the effectiveness of the abrasive grain polishing high precision dispensing needle was studied, controlling the volume fraction of silicon carbide can change the viscosity characteristics of the abrasive flow during the polishing process, so that the polishing quality of the abrasive grains can be controlled.

  14. Automated System Marketplace 1994.

    Science.gov (United States)

    Griffiths, Jose-Marie; Kertis, Kimberly

    1994-01-01

    Reports results of the 1994 Automated System Marketplace survey based on responses from 60 vendors. Highlights include changes in the library automation marketplace; estimated library systems revenues; minicomputer and microcomputer-based systems; marketplace trends; global markets and mergers; research needs; new purchase processes; and profiles…

  15. Automation in Warehouse Development

    NARCIS (Netherlands)

    Hamberg, R.; Verriet, J.

    2012-01-01

    The warehouses of the future will come in a variety of forms, but with a few common ingredients. Firstly, human operational handling of items in warehouses is increasingly being replaced by automated item handling. Extended warehouse automation counteracts the scarcity of human operators and

  16. Order Division Automated System.

    Science.gov (United States)

    Kniemeyer, Justin M.; And Others

    This publication was prepared by the Order Division Automation Project staff to fulfill the Library of Congress' requirement to document all automation efforts. The report was originally intended for internal use only and not for distribution outside the Library. It is now felt that the library community at-large may have an interest in the…

  17. Automate functional testing

    Directory of Open Access Journals (Sweden)

    Ramesh Kalindri

    2014-06-01

    Full Text Available Currently, software engineers are increasingly turning to the option of automating functional tests, but not always have successful in this endeavor. Reasons range from low planning until over cost in the process. Some principles that can guide teams in automating these tests are described in this article.

  18. Automation and robotics

    Science.gov (United States)

    Montemerlo, Melvin

    1988-01-01

    The Autonomous Systems focus on the automation of control systems for the Space Station and mission operations. Telerobotics focuses on automation for in-space servicing, assembly, and repair. The Autonomous Systems and Telerobotics each have a planned sequence of integrated demonstrations showing the evolutionary advance of the state-of-the-art. Progress is briefly described for each area of concern.

  19. Automating the Small Library.

    Science.gov (United States)

    Skapura, Robert

    1987-01-01

    Discusses the use of microcomputers for automating school libraries, both for entire systems and for specific library tasks. Highlights include available library management software, newsletters that evaluate software, constructing an evaluation matrix, steps to consider in library automation, and a brief discussion of computerized card catalogs.…

  20. Raw Milk Hygiene at Local Markets and Automatic Milk Dispenser Machines

    Directory of Open Access Journals (Sweden)

    Gheorghe Şteţca

    2014-11-01

    Full Text Available In Romania, direct sales of raw milk to the final consumer is developed based on the local regulations. These are in accordance to European Regulation that must meet some quality requirements for the total number of germs, somatic cells, without antibiotics, coming from healthy animals who did not suffer from diseases that can be transmitted to humans through milk. Raw milk is sold in Romania in local markets and by automatic milk dispenser machines. Based on these regulations, a study regarding the quality and security to human health of raw milk was conducted on the commercialized milk in local markets and automatic milk dispensers. During May-June 2014 samples of raw milk were collected from Cluj-Napoca local markets and automatic milk dispensers. All samples were kept to refrigeration conditions until the moment of analyze which took place at the sampling day. The following parameters were taken into account: fat content, protein, casein, lactose, nonfat dry matter, pH, milk freezing point, added water, antibiotics residues, milk urea, number of germ cells and somatic cells. All obtained results were verified by the validated methods applied. Our research can be forward conducted in order to verify the hygiene and composition of milk from the whole dairy chain. 

  1. Use of direct washing of chemical dispense nozzle for defect control

    Science.gov (United States)

    Linnane, Michael; Mack, George; Longstaff, Christopher; Winter, Thomas

    2006-03-01

    Demands for continued defect reduction in 300mm IC manufacturing are driving process engineers to examine all aspects of the chemical apply process for improvement. Historically, the defect contribution from photoresist apply nozzles has been minimized through a carefully controlled process of "dummy dispenses" to keep the photoresist in the tip "fresh" and remove any solidified material, a preventive maintenance regime involving periodic cleaning or replacing of the nozzles, and reliance on a pool of solvent within the nozzle storage block to keep the photoresist from solidifying at the nozzle tip. The industry standard has worked well for the most part but has limitations in terms of cost effectiveness and absolute defect elimination. In this study, we investigate the direct washing of the chemical apply nozzle to reduce defects seen on the coated wafer. Data is presented on how the direct washing of the chemical dispense nozzle can be used to reduce coating related defects, reduce material costs from the reduction of "dummy dispense", and can reduce equipment downtime related to nozzle cleaning or replacement.

  2. Measurement of microbic contamination rate in the dispensing process making suspension of barium sulfate powder

    International Nuclear Information System (INIS)

    Kim, Young Keun; Lee, Yang Sub; Cho, Cheong Chan; Ryu, Meung Sun; Lee, Kyung Sup

    2001-01-01

    The purpose of this study is to investigate the contamination rate of barium sulfate suspension made in the exposed state in usual circumstances. This study was performed in four university hospital using the contrast media by barium sulfate powder. The specimen were detected at dispensing water, agitator and mixing tank. We also classified the suspension into general bacteria, mycete and Bacillus coli infection. The tap water were used to dispense water in the all hospitals. Bacillus coli were not detected in the all. General bacteria and mycete were not detected in the one specimen, but detected in two specimen over defined value. In the contamination rate of agitator, mixing tank, and the manufactured. Bacillus coli were not detected in all. However, general bacteria and mycete were detected too numberous to count. In conclusion, the refined water must be used in dispensing water in manufacturing suspension. The disinfectant is also used in washing the agitator and mixing tank for sterilization. Hand washing is indispensable to manufacturing suspension for preventing from infection

  3. Immediate or deferred adjustment of drug regimens in multidose drug dispensing systems.

    Science.gov (United States)

    Mertens, Bram J; Kwint, Henk-Frans; van Marum, Rob J; Bouvy, Marcel L

    2018-05-18

    Multidose drug dispensing (MDD) is used to help patients take their medicines appropriately. Little is known about drug regimen changes within these MDD systems and how they are effectuated by the community pharmacist. Manual immediate adjustments of the MDD system could introduce dispensing errors. MDD guidelines therefore recommend to effectuate drug regimen changes at the start of a new MDD system. The aim of this study was to investigate the frequency, type, procedure followed, immediate necessity, and time taken to make MDD adjustments. This was a cross-sectional study in eight community pharmacies in the Netherlands. All adjustments to MDD systems were systematically documented for 3 weeks by the community pharmacist. Overall, 261 MDD adjustments involving 364 drug changes were documented for 250 patients: 127 (35%) drug changes involved the addition of a new drug, 124 (34%) a change in dosage, and 95 (26%) drug discontinuation. Of the MDD adjustments, 135 (52%) were effectuated immediately: 81 (31%) by adjusting the MDD system manually, 49 (19%) by temporarily dispensing the drug separately from the MDD system, and 5 (2%) by ordering a new MDD system. Pharmacists considered that 36 (27%) of the immediate MDD adjustments could have been deferred until the next MDD system was produced. Immediate adjustment took significantly longer than deferred adjustment (p < 0.001). This study shows that in patients using MDD systems, over half of the drug regimen changes are adjusted immediately. The necessity of these immediate changes should be critically evaluated. Copyright © 2018. Published by Elsevier Inc.

  4. Automated model building

    CERN Document Server

    Caferra, Ricardo; Peltier, Nicholas

    2004-01-01

    This is the first book on automated model building, a discipline of automated deduction that is of growing importance Although models and their construction are important per se, automated model building has appeared as a natural enrichment of automated deduction, especially in the attempt to capture the human way of reasoning The book provides an historical overview of the field of automated deduction, and presents the foundations of different existing approaches to model construction, in particular those developed by the authors Finite and infinite model building techniques are presented The main emphasis is on calculi-based methods, and relevant practical results are provided The book is of interest to researchers and graduate students in computer science, computational logic and artificial intelligence It can also be used as a textbook in advanced undergraduate courses

  5. Automation in Immunohematology

    Directory of Open Access Journals (Sweden)

    Meenu Bajpai

    2012-01-01

    Full Text Available There have been rapid technological advances in blood banking in South Asian region over the past decade with an increasing emphasis on quality and safety of blood products. The conventional test tube technique has given way to newer techniques such as column agglutination technique, solid phase red cell adherence assay, and erythrocyte-magnetized technique. These new technologies are adaptable to automation and major manufacturers in this field have come up with semi and fully automated equipments for immunohematology tests in the blood bank. Automation improves the objectivity and reproducibility of tests. It reduces human errors in patient identification and transcription errors. Documentation and traceability of tests, reagents and processes and archiving of results is another major advantage of automation. Shifting from manual methods to automation is a major undertaking for any transfusion service to provide quality patient care with lesser turnaround time for their ever increasing workload. This article discusses the various issues involved in the process.

  6. Automation in Warehouse Development

    CERN Document Server

    Verriet, Jacques

    2012-01-01

    The warehouses of the future will come in a variety of forms, but with a few common ingredients. Firstly, human operational handling of items in warehouses is increasingly being replaced by automated item handling. Extended warehouse automation counteracts the scarcity of human operators and supports the quality of picking processes. Secondly, the development of models to simulate and analyse warehouse designs and their components facilitates the challenging task of developing warehouses that take into account each customer’s individual requirements and logistic processes. Automation in Warehouse Development addresses both types of automation from the innovative perspective of applied science. In particular, it describes the outcomes of the Falcon project, a joint endeavour by a consortium of industrial and academic partners. The results include a model-based approach to automate warehouse control design, analysis models for warehouse design, concepts for robotic item handling and computer vision, and auton...

  7. Implementing a bar-code assisted medication administration system: effects on the dispensing process and user perceptions.

    Science.gov (United States)

    Samaranayake, N R; Cheung, S T D; Cheng, K; Lai, K; Chui, W C M; Cheung, B M Y

    2014-06-01

    We assessed the effects of a bar-code assisted medication administration system used without the support of computerised prescribing (stand-alone BCMA), on the dispensing process and its users. The stand-alone BCMA system was implemented in one ward of a teaching hospital. The number of dispensing steps, dispensing time and potential dispensing errors (PDEs) were directly observed one month before and eight months after the intervention. Attitudes of pharmacy and nursing staff were assessed using a questionnaire (Likert scale) and interviews. Among 1291 and 471 drug items observed before and after the introduction of the technology respectively, the number of dispensing steps increased from five to eight and time (standard deviation) to dispense one drug item by one staff personnel increased from 0.8 (0.09) to 1.5 (0.12) min. Among 2828 and 471 drug items observed before and after the intervention respectively, the number of PDEs increased significantly (Psystem offered less benefit to the dispensing process (9/16). Nursing staff perceived the system as useful in improving the accuracy of drug administration (7/10). Implementing a stand-alone BCMA system may slow down and complicate the dispensing process. Nursing staff believe the stand-alone BCMA system could improve the drug administration process but pharmacy staff believes the technology would be more helpful if supported by computerised prescribing. However, periodical assessments are needed to identify weaknesses in the process after implementation, and all users should be educated on the benefits of using this technology. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  8. Automated hand hygiene auditing with and without an intervention.

    Science.gov (United States)

    Kwok, Yen Lee Angela; Juergens, Craig P; McLaws, Mary-Louise

    2016-12-01

    Daily feedback from continuous automated auditing with a peer reminder intervention was used to improve compliance. Compliance rates from covert and overt automated auditing phases with and without intervention were compared with human mandatory audits. An automated system was installed to covertly detect hand hygiene events with each depression of the alcohol-based handrub dispenser for 5 months. The overt phase included key clinicians trained to share daily rates with clinicians, set compliance goals, and nudge each other to comply for 6 months. During a further 6 months, the intervention continued without being refreshed. Hand Hygiene Australia (HHA) human audits were performed quarterly during the intervention in accordance with the World Health Organization guidelines. Percentage point (PP) differences between compliance rates were used to determine change. HHA rates for June 2014 were 85% and 87% on the medical and surgical wards, respectively. These rates were 55 PPs and 38 PPs higher than covert automation rates for June 2014 on the medical and surgical ward at 30% and 49%, respectively. During the intervention phase, average compliance did not change on the medical ward from their covert rate, whereas the surgical ward improved compared with the covert phase by 11 PPs to 60%. On average, compliance during the intervention without being refreshed did not change on the medical ward, whereas the average rate on the surgical ward declined by 9 PPs. Automation provided a unique opportunity to respond to daily rates, but compliance will return to preintervention levels once active intervention ceases or human auditors leave the ward, unless clinicians are committed to change. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  9. Feasibility evaluation of 3 automated cellular drug screening assays on a robotic workstation.

    Science.gov (United States)

    Soikkeli, Anne; Sempio, Cristina; Kaukonen, Ann Marie; Urtti, Arto; Hirvonen, Jouni; Yliperttula, Marjo

    2010-01-01

    This study presents the implementation and optimization of 3 cell-based assays on a TECAN Genesis workstation-the Caspase-Glo 3/7 and sulforhodamine B (SRB) screening assays and the mechanistic Caco-2 permeability protocol-and evaluates their feasibility for automation. During implementation, the dispensing speed to add drug solutions and fixative trichloroacetic acid and the aspiration speed to remove the supernatant immediately after fixation were optimized. Decontamination steps for cleaning the tips and pipetting tubing were also added. The automated Caspase-Glo 3/7 screen was successfully optimized with Caco-2 cells (Z' 0.7, signal-to-base ratio [S/B] 1.7) but not with DU-145 cells. In contrast, the automated SRB screen was successfully optimized with the DU-145 cells (Z' 0.8, S/B 2.4) but not with the Caco-2 cells (Z' -0.8, S/B 1.4). The automated bidirectional Caco-2 permeability experiments separated successfully low- and high-permeability compounds (Z' 0.8, S/B 84.2) and passive drug permeation from efflux-mediated transport (Z' 0.5, S/B 8.6). Of the assays, the homogeneous Caspase-Glo 3/7 assay benefits the most from automation, but also the heterogeneous SRB assay and Caco-2 permeability experiments gain advantages from automation.

  10. The role of pharmacists and emergency contraception: Are pharmacists' perceptions of emergency contraception predictive of their dispensing practices?

    Science.gov (United States)

    Richman, Alice R; Daley, Ellen M; Baldwin, Julie; Kromrey, Jeff; O'Rourke, Kathleen; Perrin, Kay

    2012-10-01

    Pharmacists can play a critical role in the access to emergency contraception (EC). We assessed if knowledge and attitudes were predictive of EC dispensing among a statewide sample of Florida pharmacists, who have legal authority to refuse to dispense medications. In 2008, surveys were mailed to a random sample of 1264 pharmacists registered with the Florida Board of Pharmacy. Data from 272 pharmacists (22% response rate) were analyzed using bivariate and multivariate logistic regression. Fifty-six percent of respondents incorrectly answered that EC causes birth defects, and 46% replied that it causes abortion. Only 22% said that EC can be purchased in advance of need. Many felt uncomfortable dispensing to adolescents (61%) and men (58%). Knowledge about EC was the most important predictor of dispensing [odds ratio (OR)=1.57, 95% confidence interval (CI) 1.22-2.03]. In particular, pharmacists who reported that EC does not act as an abortifacient were more likely to dispense it (OR=4.64, 95% CI 2.15-10.00). Correct information about EC was the most important predictor of pharmacists' dispensing EC. To expand availability of EC, pharmacists will have to become better informed. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. What makes an automated teller machine usable by blind users?

    Science.gov (United States)

    Manzke, J M; Egan, D H; Felix, D; Krueger, H

    1998-07-01

    Fifteen blind and sighted subjects, who featured as a control group for acceptance, were asked for their requirements for automated teller machines (ATMs). Both groups also tested the usability of a partially operational ATM mock-up. This machine was based on an existing cash dispenser, providing natural speech output, different function menus and different key arrangements. Performance and subjective evaluation data of blind and sighted subjects were collected. All blind subjects were able to operate the ATM successfully. The implemented speech output was the main usability factor for them. The different interface designs did not significantly affect performance and subjective evaluation. Nevertheless, design recommendations can be derived from the requirement assessment. The sighted subjects were rather open for design modifications, especially the implementation of speech output. However, there was also a mismatch of the requirements of the two subject groups, mainly concerning the key arrangement.

  12. Automated image quality assessment for chest CT scans.

    Science.gov (United States)

    Reeves, Anthony P; Xie, Yiting; Liu, Shuang

    2018-02-01

    Medical image quality needs to be maintained at standards sufficient for effective clinical reading. Automated computer analytic methods may be applied to medical images for quality assessment. For chest CT scans in a lung cancer screening context, an automated quality assessment method is presented that characterizes image noise and image intensity calibration. This is achieved by image measurements in three automatically segmented homogeneous regions of the scan: external air, trachea lumen air, and descending aorta blood. Profiles of CT scanner behavior are also computed. The method has been evaluated on both phantom and real low-dose chest CT scans and results show that repeatable noise and calibration measures may be realized by automated computer algorithms. Noise and calibration profiles show relevant differences between different scanners and protocols. Automated image quality assessment may be useful for quality control for lung cancer screening and may enable performance improvements to automated computer analysis methods. © 2017 American Association of Physicists in Medicine.

  13. Increasing Access to Subsidized Artemisinin-based Combination Therapy through Accredited Drug Dispensing Outlets in Tanzania

    Directory of Open Access Journals (Sweden)

    Gabra Michael

    2011-06-01

    Full Text Available Abstract Background In Tanzania, many people seek malaria treatment from retail drug sellers. The National Malaria Control Program identified the accredited drug dispensing outlet (ADDO program as a private sector mechanism to supplement the distribution of subsidized artemisinin-based combination therapies (ACTs from public facilities and increase access to the first-line antimalarial in rural and underserved areas. The ADDO program strengthens private sector pharmaceutical services by improving regulatory and supervisory support, dispenser training, and record keeping practices. Methods The government's pilot program made subsidized ACTs available through ADDOs in 10 districts in the Morogoro and Ruvuma regions, covering about 2.9 million people. The program established a supply of subsidized ACTs, created a price system with a cost recovery plan, developed a plan to distribute the subsidized products to the ADDOs, trained dispensers, and strengthened the adverse drug reactions reporting system. As part of the evaluation, 448 ADDO dispensers brought their records to central locations for analysis, representing nearly 70% of ADDOs operating in the two regions. ADDO drug register data were available from July 2007-June 2008 for Morogoro and from July 2007-September 2008 for Ruvuma. This intervention was implemented from 2007-2008. Results During the pilot, over 300,000 people received treatment for malaria at the 448 ADDOs. The percentage of ADDOs that dispensed at least one course of ACT rose from 26.2% during July-September 2007 to 72.6% during April-June 2008. The number of malaria patients treated with ACTs gradually increased after the start of the pilot, while the use of non-ACT antimalarials declined; ACTs went from 3% of all antimalarials sold in July 2007 to 26% in June 2008. District-specific data showed substantial variation among the districts in ACT uptake through ADDOs, ranging from ACTs representing 10% of all antimalarial sales

  14. Robotic weeding and automated weed measurements

    DEFF Research Database (Denmark)

    Christensen, S.; Søgaard, H.T.; Jørgensen, R.N.

    2003-01-01

    The goal of decreasing herbicide usage has so far focused on reducing the herbicide dosage or replacing chemical weed control by hoeing and harrowing. The conventional weed control strategy is to apply the same dose of herbicide or the same intensity of hoeing and harrowing in the whole field. Th...... the state-of-the-art of automated weed measurement methods and the research projects concerning autonomous platform and information system for crop and weed monitoring and robotic weeding....

  15. Automated lung nodule classification following automated nodule detection on CT: A serial approach

    International Nuclear Information System (INIS)

    Armato, Samuel G. III; Altman, Michael B.; Wilkie, Joel; Sone, Shusuke; Li, Feng; Doi, Kunio; Roy, Arunabha S.

    2003-01-01

    We have evaluated the performance of an automated classifier applied to the task of differentiating malignant and benign lung nodules in low-dose helical computed tomography (CT) scans acquired as part of a lung cancer screening program. The nodules classified in this manner were initially identified by our automated lung nodule detection method, so that the output of automated lung nodule detection was used as input to automated lung nodule classification. This study begins to narrow the distinction between the 'detection task' and the 'classification task'. Automated lung nodule detection is based on two- and three-dimensional analyses of the CT image data. Gray-level-thresholding techniques are used to identify initial lung nodule candidates, for which morphological and gray-level features are computed. A rule-based approach is applied to reduce the number of nodule candidates that correspond to non-nodules, and the features of remaining candidates are merged through linear discriminant analysis to obtain final detection results. Automated lung nodule classification merges the features of the lung nodule candidates identified by the detection algorithm that correspond to actual nodules through another linear discriminant classifier to distinguish between malignant and benign nodules. The automated classification method was applied to the computerized detection results obtained from a database of 393 low-dose thoracic CT scans containing 470 confirmed lung nodules (69 malignant and 401 benign nodules). Receiver operating characteristic (ROC) analysis was used to evaluate the ability of the classifier to differentiate between nodule candidates that correspond to malignant nodules and nodule candidates that correspond to benign lesions. The area under the ROC curve for this classification task attained a value of 0.79 during a leave-one-out evaluation

  16. Systematic review automation technologies

    Science.gov (United States)

    2014-01-01

    Systematic reviews, a cornerstone of evidence-based medicine, are not produced quickly enough to support clinical practice. The cost of production, availability of the requisite expertise and timeliness are often quoted as major contributors for the delay. This detailed survey of the state of the art of information systems designed to support or automate individual tasks in the systematic review, and in particular systematic reviews of randomized controlled clinical trials, reveals trends that see the convergence of several parallel research projects. We surveyed literature describing informatics systems that support or automate the processes of systematic review or each of the tasks of the systematic review. Several projects focus on automating, simplifying and/or streamlining specific tasks of the systematic review. Some tasks are already fully automated while others are still largely manual. In this review, we describe each task and the effect that its automation would have on the entire systematic review process, summarize the existing information system support for each task, and highlight where further research is needed for realizing automation for the task. Integration of the systems that automate systematic review tasks may lead to a revised systematic review workflow. We envisage the optimized workflow will lead to system in which each systematic review is described as a computer program that automatically retrieves relevant trials, appraises them, extracts and synthesizes data, evaluates the risk of bias, performs meta-analysis calculations, and produces a report in real time. PMID:25005128

  17. Operational proof of automation

    International Nuclear Information System (INIS)

    Jaerschky, R.; Reifenhaeuser, R.; Schlicht, K.

    1976-01-01

    Automation of the power plant process may imply quite a number of problems. The automation of dynamic operations requires complicated programmes often interfering in several branched areas. This reduces clarity for the operating and maintenance staff, whilst increasing the possibilities of errors. The synthesis and the organization of standardized equipment have proved very successful. The possibilities offered by this kind of automation for improving the operation of power plants will only sufficiently and correctly be turned to profit, however, if the application of these technics of equipment is further improved and if its volume is tallied with a definite etc. (orig.) [de

  18. Automated electron microprobe

    International Nuclear Information System (INIS)

    Thompson, K.A.; Walker, L.R.

    1986-01-01

    The Plant Laboratory at the Oak Ridge Y-12 Plant has recently obtained a Cameca MBX electron microprobe with a Tracor Northern TN5500 automation system. This allows full stage and spectrometer automation and digital beam control. The capabilities of the system include qualitative and quantitative elemental microanalysis for all elements above and including boron in atomic number, high- and low-magnification imaging and processing, elemental mapping and enhancement, and particle size, shape, and composition analyses. Very low magnification, quantitative elemental mapping using stage control (which is of particular interest) has been accomplished along with automated size, shape, and composition analysis over a large relative area

  19. Chef infrastructure automation cookbook

    CERN Document Server

    Marschall, Matthias

    2013-01-01

    Chef Infrastructure Automation Cookbook contains practical recipes on everything you will need to automate your infrastructure using Chef. The book is packed with illustrated code examples to automate your server and cloud infrastructure.The book first shows you the simplest way to achieve a certain task. Then it explains every step in detail, so that you can build your knowledge about how things work. Eventually, the book shows you additional things to consider for each approach. That way, you can learn step-by-step and build profound knowledge on how to go about your configuration management

  20. Managing laboratory automation.

    Science.gov (United States)

    Saboe, T J

    1995-01-01

    This paper discusses the process of managing automated systems through their life cycles within the quality-control (QC) laboratory environment. The focus is on the process of directing and managing the evolving automation of a laboratory; system examples are given. The author shows how both task and data systems have evolved, and how they interrelate. A BIG picture, or continuum view, is presented and some of the reasons for success or failure of the various examples cited are explored. Finally, some comments on future automation need are discussed.

  1. Automated PCB Inspection System

    Directory of Open Access Journals (Sweden)

    Syed Usama BUKHARI

    2017-05-01

    Full Text Available Development of an automated PCB inspection system as per the need of industry is a challenging task. In this paper a case study is presented, to exhibit, a proposed system for an immigration process of a manual PCB inspection system to an automated PCB inspection system, with a minimal intervention on the existing production flow, for a leading automotive manufacturing company. A detailed design of the system, based on computer vision followed by testing and analysis was proposed, in order to aid the manufacturer in the process of automation.

  2. Operational proof of automation

    International Nuclear Information System (INIS)

    Jaerschky, R.; Schlicht, K.

    1977-01-01

    Automation of the power plant process may imply quite a number of problems. The automation of dynamic operations requires complicated programmes often interfering in several branched areas. This reduces clarity for the operating and maintenance staff, whilst increasing the possibilities of errors. The synthesis and the organization of standardized equipment have proved very successful. The possibilities offered by this kind of automation for improving the operation of power plants will only sufficiently and correctly be turned to profit, however, if the application of these equipment techniques is further improved and if it stands in a certain ratio with a definite efficiency. (orig.) [de

  3. Dose rate measuring device and dose rate measuring method using the same

    International Nuclear Information System (INIS)

    Urata, Megumu; Matsushita, Takashi; Hanazawa, Sadao; Konno, Takahiro; Chiba, Yoshinori; Yumitate, Tadahiro

    1998-01-01

    The device of the present invention comprises a scintillation fiber scope having a shape elongated in the direction of the height of a pressure vessel and emitting light by incident of radiation to detect radiation, a radioactivity measuring device for measuring a dose rate based on the detection of the fiber scope and a reel means for dispensing and taking up the fiber scope, and it constituted such that the dose rate of the pressure vessel and that of a shroud are determined independently. Then, when the taken out shroud is contained in an container, excessive shielding is not necessary, in addition, this device can reliably be inserted to or withdrawn from complicated places between the pressure vessel and the shroud, and further, the dose rate of the pressure vessel and that of the shroud can be measured approximately accurately even when the thickness of them is different greatly. (N.H.)

  4. Dose rate measuring device and dose rate measuring method using the same

    Energy Technology Data Exchange (ETDEWEB)

    Urata, Megumu; Matsushita, Takashi; Hanazawa, Sadao; Konno, Takahiro; Chiba, Yoshinori; Yumitate, Tadahiro

    1998-11-13

    The device of the present invention comprises a scintillation fiber scope having a shape elongated in the direction of the height of a pressure vessel and emitting light by incident of radiation to detect radiation, a radioactivity measuring device for measuring a dose rate based on the detection of the fiber scope and a reel means for dispensing and taking up the fiber scope, and it constituted such that the dose rate of the pressure vessel and that of a shroud are determined independently. Then, when the taken out shroud is contained in an container, excessive shielding is not necessary, in addition, this device can reliably be inserted to or withdrawn from complicated places between the pressure vessel and the shroud, and further, the dose rate of the pressure vessel and that of the shroud can be measured approximately accurately even when the thickness of them is different greatly. (N.H.)

  5. Hard beta and gamma emissions of 124I. Impact on occupational dose in PET/CT.

    Science.gov (United States)

    Kemerink, G J; Franssen, R; Visser, M G W; Urbach, C J A; Halders, S G E A; Frantzen, M J; Brans, B; Teule, G J J; Mottaghy, F M

    2011-01-01

    The hard beta and gamma radiation of 124I can cause high doses to PET/CT workers. In this study we tried to quantify this occupational exposure and to optimize radioprotection. Thin MCP-Ns thermoluminescent dosimeters suitable for measuring beta and gamma radiation were used for extremity dosimetry, active personal dosimeters for whole-body dosimetry. Extremity doses were determined during dispensing of 124I and oral administration of the activity to the patient, the body dose during all phases of the PET/CT procedure. In addition, dose rates of vials and syringes as used in clinical practice were measured. The procedure for dispensing 124I was optimized using newly developed shielding. Skin dose rates up to 100 mSv/min were measured when in contact with the manufacturer's vial containing 370 MBq of 124I. For an unshielded 5 ml syringe the positron skin dose was about seven times the gamma dose. Before optimization of the preparation of 124I, using an already reasonably safe technique, the highest mean skin dose caused by handling 370 MBq was 1.9 mSv (max. 4.4 mSv). After optimization the skin dose was below 0.2 mSv. The highly energetic positrons emitted by 124I can cause high skin doses if radioprotection is poor. Under optimized conditions occupational doses are acceptable. Education of workers is of paramount importance.

  6. Automated Vehicles Symposium 2015

    CERN Document Server

    Beiker, Sven

    2016-01-01

    This edited book comprises papers about the impacts, benefits and challenges of connected and automated cars. It is the third volume of the LNMOB series dealing with Road Vehicle Automation. The book comprises contributions from researchers, industry practitioners and policy makers, covering perspectives from the U.S., Europe and Japan. It is based on the Automated Vehicles Symposium 2015 which was jointly organized by the Association of Unmanned Vehicle Systems International (AUVSI) and the Transportation Research Board (TRB) in Ann Arbor, Michigan, in July 2015. The topical spectrum includes, but is not limited to, public sector activities, human factors, ethical and business aspects, energy and technological perspectives, vehicle systems and transportation infrastructure. This book is an indispensable source of information for academic researchers, industrial engineers and policy makers interested in the topic of road vehicle automation.

  7. Hydrometeorological Automated Data System

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Office of Hydrologic Development of the National Weather Service operates HADS, the Hydrometeorological Automated Data System. This data set contains the last 48...

  8. Automated External Defibrillator

    Science.gov (United States)

    ... leads to a 10 percent reduction in survival. Training To Use an Automated External Defibrillator Learning how to use an AED and taking a CPR (cardiopulmonary resuscitation) course are helpful. However, if trained ...

  9. Planning for Office Automation.

    Science.gov (United States)

    Mick, Colin K.

    1983-01-01

    Outlines a practical approach to planning for office automation termed the "Focused Process Approach" (the "what" phase, "how" phase, "doing" phase) which is a synthesis of the problem-solving and participatory planning approaches. Thirteen references are provided. (EJS)

  10. Fixed automated spray technology.

    Science.gov (United States)

    2011-04-19

    This research project evaluated the construction and performance of Boschungs Fixed Automated : Spray Technology (FAST) system. The FAST system automatically sprays de-icing material on : the bridge when icing conditions are about to occur. The FA...

  11. Automated Vehicles Symposium 2014

    CERN Document Server

    Beiker, Sven; Road Vehicle Automation 2

    2015-01-01

    This paper collection is the second volume of the LNMOB series on Road Vehicle Automation. The book contains a comprehensive review of current technical, socio-economic, and legal perspectives written by experts coming from public authorities, companies and universities in the U.S., Europe and Japan. It originates from the Automated Vehicle Symposium 2014, which was jointly organized by the Association for Unmanned Vehicle Systems International (AUVSI) and the Transportation Research Board (TRB) in Burlingame, CA, in July 2014. The contributions discuss the challenges arising from the integration of highly automated and self-driving vehicles into the transportation system, with a focus on human factors and different deployment scenarios. This book is an indispensable source of information for academic researchers, industrial engineers, and policy makers interested in the topic of road vehicle automation.

  12. Automation Interface Design Development

    Data.gov (United States)

    National Aeronautics and Space Administration — Our research makes its contributions at two levels. At one level, we addressed the problems of interaction between humans and computers/automation in a particular...

  13. I-94 Automation FAQs

    Data.gov (United States)

    Department of Homeland Security — In order to increase efficiency, reduce operating costs and streamline the admissions process, U.S. Customs and Border Protection has automated Form I-94 at air and...

  14. Automation synthesis modules review

    International Nuclear Information System (INIS)

    Boschi, S.; Lodi, F.; Malizia, C.; Cicoria, G.; Marengo, M.

    2013-01-01

    The introduction of 68 Ga labelled tracers has changed the diagnostic approach to neuroendocrine tumours and the availability of a reliable, long-lived 68 Ge/ 68 Ga generator has been at the bases of the development of 68 Ga radiopharmacy. The huge increase in clinical demand, the impact of regulatory issues and a careful radioprotection of the operators have boosted for extensive automation of the production process. The development of automated systems for 68 Ga radiochemistry, different engineering and software strategies and post-processing of the eluate were discussed along with impact of automation with regulations. - Highlights: ► Generators availability and robust chemistry boosted for the huge diffusion of 68Ga radiopharmaceuticals. ► Different technological approaches for 68Ga radiopharmaceuticals will be discussed. ► Generator eluate post processing and evolution to cassette based systems were the major issues in automation. ► Impact of regulations on the technological development will be also considered

  15. Disassembly automation automated systems with cognitive abilities

    CERN Document Server

    Vongbunyong, Supachai

    2015-01-01

    This book presents a number of aspects to be considered in the development of disassembly automation, including the mechanical system, vision system and intelligent planner. The implementation of cognitive robotics increases the flexibility and degree of autonomy of the disassembly system. Disassembly, as a step in the treatment of end-of-life products, can allow the recovery of embodied value left within disposed products, as well as the appropriate separation of potentially-hazardous components. In the end-of-life treatment industry, disassembly has largely been limited to manual labor, which is expensive in developed countries. Automation is one possible solution for economic feasibility. The target audience primarily comprises researchers and experts in the field, but the book may also be beneficial for graduate students.

  16. Highway Electrification And Automation

    OpenAIRE

    Shladover, Steven E.

    1992-01-01

    This report addresses how the California Department of Transportation and the California PATH Program have made efforts to evaluate the feasibility and applicability of highway electrification and automation technologies. In addition to describing how the work was conducted, the report also describes the findings on highway electrification and highway automation, with experimental results, design study results, and a region-wide application impacts study for Los Angeles.

  17. Automated lattice data generation

    Directory of Open Access Journals (Sweden)

    Ayyar Venkitesh

    2018-01-01

    Full Text Available The process of generating ensembles of gauge configurations (and measuring various observables over them can be tedious and error-prone when done “by hand”. In practice, most of this procedure can be automated with the use of a workflow manager. We discuss how this automation can be accomplished using Taxi, a minimal Python-based workflow manager built for generating lattice data. We present a case study demonstrating this technology.

  18. Automated lattice data generation

    Science.gov (United States)

    Ayyar, Venkitesh; Hackett, Daniel C.; Jay, William I.; Neil, Ethan T.

    2018-03-01

    The process of generating ensembles of gauge configurations (and measuring various observables over them) can be tedious and error-prone when done "by hand". In practice, most of this procedure can be automated with the use of a workflow manager. We discuss how this automation can be accomplished using Taxi, a minimal Python-based workflow manager built for generating lattice data. We present a case study demonstrating this technology.

  19. Automated security management

    CERN Document Server

    Al-Shaer, Ehab; Xie, Geoffrey

    2013-01-01

    In this contributed volume, leading international researchers explore configuration modeling and checking, vulnerability and risk assessment, configuration analysis, and diagnostics and discovery. The authors equip readers to understand automated security management systems and techniques that increase overall network assurability and usability. These constantly changing networks defend against cyber attacks by integrating hundreds of security devices such as firewalls, IPSec gateways, IDS/IPS, authentication servers, authorization/RBAC servers, and crypto systems. Automated Security Managemen

  20. Marketing automation supporting sales

    OpenAIRE

    Sandell, Niko

    2016-01-01

    The past couple of decades has been a time of major changes in marketing. Digitalization has become a permanent part of marketing and at the same time enabled efficient collection of data. Personalization and customization of content are playing a crucial role in marketing when new customers are acquired. This has also created a need for automation to facilitate the distribution of targeted content. As a result of successful marketing automation more information of the customers is gathered ...

  1. Instant Sikuli test automation

    CERN Document Server

    Lau, Ben

    2013-01-01

    Get to grips with a new technology, understand what it is and what it can do for you, and then get to work with the most important features and tasks. A concise guide written in an easy-to follow style using the Starter guide approach.This book is aimed at automation and testing professionals who want to use Sikuli to automate GUI. Some Python programming experience is assumed.

  2. Managing laboratory automation

    OpenAIRE

    Saboe, Thomas J.

    1995-01-01

    This paper discusses the process of managing automated systems through their life cycles within the quality-control (QC) laboratory environment. The focus is on the process of directing and managing the evolving automation of a laboratory; system examples are given. The author shows how both task and data systems have evolved, and how they interrelate. A BIG picture, or continuum view, is presented and some of the reasons for success or failure of the various examples cited are explored. Fina...

  3. Shielded cells transfer automation

    International Nuclear Information System (INIS)

    Fisher, J.J.

    1984-01-01

    Nuclear waste from shielded cells is removed, packaged, and transferred manually in many nuclear facilities. Radiation exposure is absorbed by operators during these operations and limited only through procedural controls. Technological advances in automation using robotics have allowed a production waste removal operation to be automated to reduce radiation exposure. The robotic system bags waste containers out of glove box and transfers them to a shielded container. Operators control the system outside the system work area via television cameras. 9 figures

  4. Automated Status Notification System

    Science.gov (United States)

    2005-01-01

    NASA Lewis Research Center's Automated Status Notification System (ASNS) was born out of need. To prevent "hacker attacks," Lewis' telephone system needed to monitor communications activities 24 hr a day, 7 days a week. With decreasing staff resources, this continuous monitoring had to be automated. By utilizing existing communications hardware, a UNIX workstation, and NAWK (a pattern scanning and processing language), we implemented a continuous monitoring system.

  5. Automated data processing and radioassays.

    Science.gov (United States)

    Samols, E; Barrows, G H

    1978-04-01

    Radioassays include (1) radioimmunoassays, (2) competitive protein-binding assays based on competition for limited antibody or specific binding protein, (3) immunoradiometric assay, based on competition for excess labeled antibody, and (4) radioreceptor assays. Most mathematical models describing the relationship between labeled ligand binding and unlabeled ligand concentration have been based on the law of mass action or the isotope dilution principle. These models provide useful data reduction programs, but are theoretically unfactory because competitive radioassay usually is not based on classical dilution principles, labeled and unlabeled ligand do not have to be identical, antibodies (or receptors) are frequently heterogenous, equilibrium usually is not reached, and there is probably steric and cooperative influence on binding. An alternative, more flexible mathematical model based on the probability or binding collisions being restricted by the surface area of reactive divalent sites on antibody and on univalent antigen has been derived. Application of these models to automated data reduction allows standard curves to be fitted by a mathematical expression, and unknown values are calculated from binding data. The vitrues and pitfalls are presented of point-to-point data reduction, linear transformations, and curvilinear fitting approaches. A third-order polynomial using the square root of concentration closely approximates the mathematical model based on probability, and in our experience this method provides the most acceptable results with all varieties of radioassays. With this curvilinear system, linear point connection should be used between the zero standard and the beginning of significant dose response, and also towards saturation. The importance is stressed of limiting the range of reported automated assay results to that portion of the standard curve that delivers optimal sensitivity. Published methods for automated data reduction of Scatchard plots

  6. Understanding the Role of Accredited Drug Dispensing Outlets in Tanzania's Health System.

    Directory of Open Access Journals (Sweden)

    Martha Embrey

    Full Text Available People in many low-income countries access medicines from retail drug shops. In Tanzania, a public-private partnership launched in 2003 used an accreditation approach to improve access to quality medicines and pharmaceutical services in underserved areas. The government scaled up the accredited drug dispensing outlet (ADDO program nationally, with over 9,000 shops now accredited. This study assessed the relationships between community members and their sources of health care and medicines, particularly antimicrobials, with a specific focus on the role ADDOs play in the health care system.Using mixed methods, we collected data in four regions. We surveyed 1,185 households and audited 96 ADDOs and 84 public/nongovernmental health facilities using a list of 17 tracer drugs. To determine practices in health facilities, we interviewed 1,365 exiting patients. To assess dispensing practices, mystery shoppers visited 306 ADDOs presenting one of three scenarios (102 each about a child's respiratory symptoms.Of 614 household members with a recent acute illness, 73% sought outside care-30% at a public facility and 31% at an ADDO. However, people bought medicines more often at ADDOs no matter who recommended the treatment; of the 581 medicines that people had received, 49% came from an ADDO. Although health facilities and ADDOs had similar availability of antimicrobials, ADDOs had more pediatric formulations available (p<0.001. The common perception was that drugs from ADDOs are more expensive, but the difference in the median cost to treat pneumonia was relatively minimal (US$0.26 in a public facility and US$0.30 in an ADDO. Over 20% of households said they had someone with a chronic condition, with 93% taking medication, but ADDOs are allowed to sell very few chronic care-related medicines. ADDO dispensers are trained to refer complicated cases to a health facility, and notably, 99% of mystery shoppers presenting a pneumonia scenario received an

  7. Automated Groundwater Screening

    International Nuclear Information System (INIS)

    Taylor, Glenn A.; Collard, Leonard B.

    2005-01-01

    The Automated Intruder Analysis has been extended to include an Automated Ground Water Screening option. This option screens 825 radionuclides while rigorously applying the National Council on Radiation Protection (NCRP) methodology. An extension to that methodology is presented to give a more realistic screening factor for those radionuclides which have significant daughters. The extension has the promise of reducing the number of radionuclides which must be tracked by the customer. By combining the Automated Intruder Analysis with the Automated Groundwater Screening a consistent set of assumptions and databases is used. A method is proposed to eliminate trigger values by performing rigorous calculation of the screening factor thereby reducing the number of radionuclides sent to further analysis. Using the same problem definitions as in previous groundwater screenings, the automated groundwater screening found one additional nuclide, Ge-68, which failed the screening. It also found that 18 of the 57 radionuclides contained in NCRP Table 3.1 failed the screening. This report describes the automated groundwater screening computer application

  8. Polymer dispensing and embossing technology for the lens type LED packaging

    Science.gov (United States)

    Chien, Chien-Lin Chang; Huang, Yu-Che; Hu, Syue-Fong; Chang, Chung-Min; Yip, Ming-Chuen; Fang, Weileun

    2013-06-01

    This study presents a ring-type micro-structure design on the substrate and its corresponding micro fabrication processes for a lens-type light-emitting diode (LED) package. The dome-type or crater-type silicone lenses are achieved by a dispensing and embossing process rather than a molding process. Silicone with a high viscosity and thixotropy index is used as the encapsulant material. The ring-type micro structure is adopted to confine the dispensed silicone encapsulant so as to form the packaged lens. With the architecture and process described, this LED package technology herein has three merits: (1) the flexibility of lens-type LED package designs is enhanced; (2) a dome-type package design is used to enhance the intensity; (3) a crater-type package design is used to enhance the view angle. Measurement results show the ratio between the lens height and lens radius can vary from 0.4 to 1 by changing the volume of dispensed silicone. The view angles of dome-type and crater-type packages can reach 155° ± 5° and 175° ± 5°, respectively. As compared with the commercial plastic leaded chip carrier-type package, the luminous flux of a monochromatic blue light LED is improved by 15% by the dome-type package (improved by 7% by the crater-type package) and the luminous flux of a white light LED is improved by 25% by the dome-type package (improved by 13% by the crater-type package). The luminous flux of monochromatic blue light LED and white light LED are respectively improved by 8% and 12% by the dome-type package as compare with the crater-type package.

  9. Control of microbial contamination in drinking water from microfiltering dispensers by dialysis ultrafilters

    Directory of Open Access Journals (Sweden)

    Bolelli Luca

    2016-12-01

    Full Text Available Tap water filtering devices are widely employed to improve odor and taste of tap water, or to obtain refrigerated or sparkling drinking water. The presence of disinfectants-resistant bacteria in tap water is responsible of the biofilm formation inside tubes and tanks. The consequent contamination of dispensed water is a well-known hygiene problem because of the quite constant presence of potentially pathogenic bacteria likes P. aeruginosa. In this study, we tested the technical feasibility and effectiveness of the addition to different commercial devices of a packaged polysulphone fibers filter. We aimed to find a simple solution to implement the quality of the delivered water. Water contamination levels were determined in a wide selection of microfiltered water dispensers and we selected among them a representative group of 10 devices, new or in use. The packaged ultrafilter was introduced in about half of them, to monitor, when possible, in parallel the contamination levels and flow rate of a couple of identical units, with and without the filter. The placement of the dialysis filters resulted feasible at different positions along the water circuits of the variously designed filtration units. Delivered water resulted completely free from bacteria when the filter was placed exactly at, or very close to, the outlet in spite of the inner surfaces contamination. This performance was not obtained in presence of a more or less long tract of water circuits downstream the ultrafilter: a significant but not complete reduction of the plate count numbers was observed. The filters worked in continue over the whole study period, ten months, showing exactly the same efficiency. Moreover, the flow rate in presence of the filter was quite unaffected. The addition of this kind of filter to already in use water dispensers was technically easy, and its use can be recommended in all cases a simple but reliable water sanitization is requested.

  10. Using Multispectral Imaging to Measure Temperature Profiles and Emissivity of Large Thermionic Dispenser, Cathodes

    International Nuclear Information System (INIS)

    Simmons, D.F.; Fortgang, C.M.; Holtkamp, D.B.

    2001-01-01

    Thermionic dispenser cathodes are widely used in modern high-power microwave tubes. Use of these cathodes has led to significant improvement in performance. In recent years these cathodes have been used in electron linear accelerators (LINACs), particularly in induction LINACs, such as the Experimental Test Accelerator at Lawrence Livermore National Laboratory and the Relativistic Test Accelerator at Lawrence Berkeley National Laboratory. For induction LINACs, the thermionic dispenser cathode provides greater reproducibility, longer pulse lengths, and lower emittance beams than does a field emission cathode. Los Alamos National Laboratory is fabricating a dual-axis X-ray radiography machine called dual-axis radiograph hydrodynamic test (DARHT). The second axis of DARHT consists of a 2-kA, 20-MeV induction LINAC that uses a 3.2-MeV electron gun with a tungsten thermionic-dispenser cathode. Typically the DARHT cathode current density is 10 A/cm 2 at 1050 C. Under these conditions current density is space-charge limited, which is desirable since current density is independent of temperature. At lower temperature (the temperature-limited regime) there are variations in the local current density due to a nonuniform temperature profile. To obtain the desired uniform current density associated with space-charge limited operation, the coolest area on the cathode must be at a sufficiently high temperature so that the emission is space-charge limited. Consequently, the rest of the cathode is emitting at the same space-charge-limited current density but is at a higher temperature than necessary. Because cathode lifetime is such a strong function of cathode temperature, there is a severe penalty for nonuniformity in the cathode temperature. For example, a temperature increase of 50 C means cathode lifetime will decrease by a factor of at least four. Therefore, we are motivated to measure the temperature profiles of our large-area cathodes

  11. Evaluation of antibiotics dispensing profile in Tubarão, Santa Catarina, Brazil

    Directory of Open Access Journals (Sweden)

    Claudia Rauber

    2009-12-01

    Full Text Available Antibiotics are drugs widely used in prophylaxis and treatment of a great number of diseases. However, their use must be carefully controlled as acquisition in pharmacies, often without medical prescription, is elevated. The role of pharmacists in these circumstances is to practice dispensation in a rational manner. Through a structured questionnaire with open and closed questions, this study investigated the profile of antibiotics dispensed in pharmacies of Tubarão, Santa Catarina, Brazil. From the responses, it was observed that 85.0% dispense this class of medicine without medical prescription, mainly for treatment of respiratory (62.8% and urinary (12.0% tract disorders. Moreover, pharmacists' guidance was largely focused on posology (66.6% and drug interaction (12.6%, in addition to the interactions with contraceptives, alcohol and milk. The importance of avoiding antibiotics dispensation without medical prescription must be emphasized, as well as the benefits of educating the population to promote the rational use of medicines.Antibióticos são fármacos amplamente utilizados na profilaxia e no tratamento de grande número de doenças. Entretanto, seu uso deve ser cuidadosamente controlado nas farmácias, uma vez que nestas a aquisição sem prescrição médica é elevada. O papel dos farmacêuticos nessas circunstâncias é o de praticar a dispensação de maneira racional. Por meio de questionário estruturado, com questões abertas e fechadas, investigou-se o perfil dos antibióticos dispensados em farmácias de Tubarão, Santa Catarina, Brasil. Pelas respostas, observou-se que 85% das dispensa essa classe de medicamentos sem prescrição médica, principalmente para o tratamento de problemas dos tratos respiratório (62,8% e urinário (12,0%. Além disso, a orientação dos farmacêuticos se focou amplamente na posologia (66,6%e nas interações com fármacos (12,6%, em adição às interações com anticoncepcionais, álcool e

  12. A model for drug dispensing service based on the care process in the Brazilian health system

    Directory of Open Access Journals (Sweden)

    Luciano Soares

    2013-03-01

    Full Text Available Access to medication emphasizes the availability of the product at the expense of providing a service. The goal of this paper is to propose a theoretical model for a drug dispensing service, beginning with a reflection on the current realities of the Unified Health System and drug dispensation in Brazil. A conceptual analytical research made by a methodological course called disciplined imagination was mainly the approach applied to develop the model. The drug dispensing service is part of the care process, which considers access as an attribute; reception, connection and accountability, management, and clinical pharmaceutical aspects as components; and the rational use of drugs as the purpose. The proposed model addresses access to the dispensing service and demands a reorientation of routines, instruments, and practices.O acesso a medicamentos enfatiza a disponibilidade do produto em detrimento da provisão de um serviço. O objetivo deste trabalho é propor um modelo teórico para um serviço de dispensação de medicamentos, iniciando com uma reflexão sobre a realidade atual do Sistema Único de Saúde e a dispensação de medicamentos no Brasil. Uma pesquisa analítica conceitual realizada por meio de um percurso metodológico chamado de imaginação disciplinada constituiu a estratégia principal para o desenvolvimento do modelo. O serviço de dispensação é parte do processo de cuidado, o qual considera o acesso como um atributo; os aspectos acolhimento, vínculo e responsabilização, gestão e clínica farmacêutica como componentes e o uso racional de medicamentos como o propósito. O modelo proposto direciona o acesso para o serviço de dispensação e demanda a reorientação de rotinas, instrumentos e práticas.

  13. Gene disruption reveals a dispensable role for plasmepsin VII in the Plasmodium berghei life cycle.

    Science.gov (United States)

    Mastan, Babu S; Kumari, Anchala; Gupta, Dinesh; Mishra, Satish; Kumar, Kota Arun

    2014-06-01

    Plasmepsins (PM), aspartic proteases of Plasmodium, comprises a family of ten proteins that perform critical functions in Plasmodium life cycle. Except VII and VIII, functions of the remaining plasmepsin members have been well characterized. Here, we have generated a mutant parasite lacking PM VII in Plasmodium berghei using reverse genetics approach. Systematic comparison of growth kinetics and infection in both mosquito and vertebrate host revealed that PM VII depleted mutants exhibited no defects in development and progressed normally throughout the parasite life cycle. These studies suggest a dispensable role for PM VII in Plasmodium berghei life cycle. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Drug dispensing practices at pharmacies in Bengaluru: A cross-sectional study

    OpenAIRE

    R Soumya; Vijayalakshmi Devarashetty; C R Jayanthi; M Sushma

    2016-01-01

    Objectives: Pharmacists are one of the crucial focal points for health care in the community. They have tremendous outreach to the public as pharmacies are often the first-port-of-call. With the increase of ready-to-use drugs, the main health-related activity of a pharmacist today is to assure the quality of dispensing, a key element to promote rational medicine use. Materials and Methods: A cross-sectional study of 200 pharmacies, 100 each in various residential (R) and commercial (C) areas ...

  15. International Space Station (ISS) Potable Water Dispenser (PWD) Beverage Adapter (BA) Redesign

    Science.gov (United States)

    Edgerly, Rachel; Benoit, Jace; Shindo, David

    2012-01-01

    The Potable Water Dispenser used on the International Space Station (ISS) interfaces with food and drink packages using the Beverage Adapter and Needle. Unexpected leakage has been seen in this interface. The Beverage Adapter used on ]orbit was returned to the ground for Test, Teardown, and Evaluation. The results of that investigation prompted a redesign of the Beverage Adapter and Needle. The Beverage Adapter materials were changed to be more corrosion resistant, and the Needle was redesigned to preclude leakage. The redesigns have been tested and proven.

  16. Dose limits

    International Nuclear Information System (INIS)

    Fitoussi, L.

    1987-12-01

    The dose limit is defined to be the level of harmfulness which must not be exceeded, so that an activity can be exercised in a regular manner without running a risk unacceptable to man and the society. The paper examines the effects of radiation categorised into stochastic and non-stochastic. Dose limits for workers and the public are discussed

  17. SYSTEM OF PRECISE DOSING OF COAGULANT IN THE PULVERIZING AERATOR POWERED BY WIND USING FUZZY LOGIC

    Directory of Open Access Journals (Sweden)

    Andrzej Osuch

    2017-06-01

    Full Text Available One of the methods used to support land restoration lakes is the method of pulverizing aeration. Use of aerators powered exclusively by wind improves the condition of reservoirs, while not compromising the environment. The pulverizing aeration process drive is windy on the water aeration zone near bottom, while removing harmful gases anaerobic metabolism. Aerators of this type due to the unique method of operation also enable dosing of inactivation coagulants with oxygenated water to the depths of the lake. Mileage coagulant dosing can be made dependent on the speed of the wind, which has an impact on the performance of his work, because with the increase of wind speed dispensing valve coagulants should be stronger open. One of the methods for assessing the state of lakes is to measure water transparency. The softer visibility, the most likely state of the water is better. Dosage of coagulant so you can make the transparency of the water. Similarly, with increasing transparency water dispensing valve should be more covered up. Control of the drain valve dispenser coagulant can be simultaneously dependent on two factors. The study was designed method of control drain valve dispenser coagulant using fuzzy inference.

  18. Monitored Retrievable Storage/Multi-Purpose Canister analysis: Simulation and economics of automation

    International Nuclear Information System (INIS)

    Bennett, P.C.; Stringer, J.B.

    1994-01-01

    Robotic automation is examined as a possible alternative to manual spent nuclear fuel, transport cask and Multi-Purpose canister (MPC) handling at a Monitored Retrievable Storage (MRS) facility. Automation of key operational aspects for the MRS/MPC system are analyzed to determine equipment requirements, through-put times and equipment costs is described. The economic and radiation dose impacts resulting from this automation are compared to manual handling methods

  19. College Cafeteria Signage Increases Water Intake but Water Position on the Soda Dispenser Encourages More Soda Consumption.

    Science.gov (United States)

    Montuclard, Astrid Linn; Park-Mroch, Jennifer; O'Shea, Amy M J; Wansink, Brian; Irvin, Jill; Laroche, Helena H

    2017-10-01

    To evaluate the effects of improved water location visibility and water dispenser position on the soda dispenser on undergraduate students' beverage choices. Two focus groups with pilot intervention surveys before and after, adding a small sign above the soda dispensers' water button for 6 weeks in a large US university's all-you-can-eat, prepaid dining hall (measured with chi-square tests and logistic and ordinal logistic regression). Focus groups included 15 students. Survey participants included 357 students before and 301 after the intervention. After the intervention, more students reported ever having drunk water with the meal (66.4% to 77.0%; P = .003) and water consumption frequency increased (P = .005). Postintervention, the odds of drinking water increased by 1.57. Preference for other drinks was the main reason for not drinking water. A total of 59% of students had ever changed their preference from water to soda. The clear indication of the water's location increased students' reported water consumption. Further investigation is needed into how a non-independent water dispenser influences students' beverage choice. Clearly labeled, independent water dispensers are recommended. Copyright © 2017 Society for Nutrition Education and Behavior. All rights reserved.

  20. A Review of the Anthropometric Characteristics, Grading and Dispensation of Junior and Youth Rugby Union Players in Australia.

    Science.gov (United States)

    Patton, Declan Alexander; McIntosh, Andrew Stuart; Denny, Greg

    2016-08-01

    The grading of Australian junior and youth rugby union players has received substantial media attention in recent years. Media reports have focussed on size mismatches observed between players, especially players with Polynesian heritage, and the concerned parents who fear for the safety of their child owing to perceived mismatches. Although such concerns are well meaning, few media reports recognise the need for substantial evidence to determine the best grading system for junior and youth rugby union players. The current study reviewed relevant literature pertinent to the grading and dispensation of junior and youth rugby union players. Using primary and secondary search strategies, a total of 33 articles reporting the anthropometric characteristics of junior and youth rugby players were identified. Anthropometric data from the literature were compared with normative population data and currently used dispensation criteria. Junior and youth rugby players were found to be taller and heavier than normative population data. Current dispensation criteria, in terms of body mass, were found to vary and it is suggested that criteria be revised and standardised across rugby unions throughout Australia. Although it is acknowledged that other factors are important for grading players, anthropometric characteristics should be considered as potential dispensation criteria to supplement current age-based grading for junior and youth rugby union players. Measuring the body mass and stature of each junior player upon pre-season registration is suggested, which would provide data to establish valid dispensation criteria for the following season.

  1. Recent trends in the dispensing of 90-day-supply prescriptions at retail pharmacies: implications for improved convenience and access.

    Science.gov (United States)

    Liberman, Joshua N; Girdish, Charmaine

    2011-03-01

    Mail-service pharmacies offer consumers the convenience of prescriptions filled with a 90-day supply of medication. Unlike mail-service pharmacies, retail pharmacies traditionally dispensed maintenance medication prescriptions with a 30-day supply. However, the retail landscape changed in May 2008 with Walmart's announcement of an extension of its $4 Prescription Program to include 90-day-supply prescriptions. To evaluate recent changes in access to and use of 90-day-supply maintenance medications dispensed via retail pharmacy. As of the first quarter of 2007, the proportion of retail-dispensed maintenance medications with a 90-day supply (compared with all maintenance prescriptions dispensed) among Medicare Part D plans, self-insured employers, and private health plans was 5.1%, 5.1%, and 5.0%, respectively. As of December 2009, this ratio had risen to 8.0% for Medicare plans and 8.1% for commercial health plans; the ratio among employers had risen more modestly to 6.1%. Of particular interest and importance, the proportion increased similarly for brand and for generic medications. There has been substantial growth in 90-day prescriptions dispensed via retail pharmacy, a trend that is likely to continue as more insurance providers adopt compatible benefit designs. It is important to continue monitoring these trends and to identify opportunities to rigorously evaluate their impact on medication adherence and healthcare costs.

  2. Effect of holed reflector on acoustic radiation force in noncontact ultrasonic dispensing of small droplets

    Science.gov (United States)

    Tanaka, Hiroki; Wada, Yuji; Mizuno, Yosuke; Nakamura, Kentaro

    2016-06-01

    We investigated the fundamental aspects of droplet dispensing, which is an important procedure in the noncontact ultrasonic manipulation of droplets in air. A holed reflector was used to dispense a droplet from a 27.4 kHz standing-wave acoustic field to a well. First, the relationship between the hole diameter of the reflector and the acoustic radiation force acting on a levitated droplet was clarified by calculating the acoustic impedance of the point just above the hole. When the hole diameter was half of (or equal to) the acoustic wavelength λ, the acoustic radiation force was ∼80% (or 50%) of that without a hole. The maximal diameters of droplets levitated above the holes through flat and half-cylindrical reflectors were then experimentally investigated. For instance, with the half-cylindrical reflector, the maximal diameter was 5.0 mm for a hole diameter of 6.0 mm, and droplets were levitatable up to a hole diameter of 12 mm (∼λ).

  3. Molecular Epidemiology of a Pseudomonas aeruginosa Hospital Outbreak Driven by a Contaminated Disinfectant-Soap Dispenser

    Science.gov (United States)

    Lanini, Simone; D'Arezzo, Silvia; Puro, Vincenzo; Martini, Lorena; Imperi, Francesco; Piselli, Pierluca; Montanaro, Marco; Paoletti, Simonetta; Visca, Paolo; Ippolito, Giuseppe

    2011-01-01

    Background and Objective Pseudomonas aeruginosa infection represents a main cause of morbidity and mortality among immunocompromised patients. This study describes a fatal epidemic of P. aeruginosa that occurred in a hematology unit in Italy. Methods Retrospective cohort study, prospective surveillance, auditing, extensive testing on healthcare workers and environmental investigation were performed to define the dynamics and potential causes of transmission. RAPD, macrorestriction analyses and sequence typing were used to define relationships between P. aeruginosa isolates. Results Eighteen cases of infection were identified in the different phases of the investigation. Of these, five constitute a significant molecular cluster of infection. A P. aeruginosa strain with the same genetic fingerprint and sequence type (ST175) as clinical isolates strain was also isolated from a heavily contaminated triclosan soap dispenser. Discussion and Conclusions Our results are consistent with the hypothesis that patients became indirectly infected, e.g., during central venous catheter handling through contaminated items, and that the triclosan soap dispenser acted as a common continuous source of P. aeruginosa infection. Since P. aeruginosa is intrinsically unsusceptible to triclosan, the use of triclosan-based disinfectant formulations should be avoided in those healthcare settings hosting patients at high risk of P. aeruginosa infection. PMID:21359222

  4. Prescription Drug Monitoring Programs and Pharmacist Orientation Toward Dispensing Controlled Substances.

    Science.gov (United States)

    Fendrich, Michael; Bryan, Janelle K; Hooyer, Katinka

    2018-01-03

    We sought to understand how pharmacists viewed and used a newly implemented prescription drug monitoring program (PDMP). We also sought to understand pharmacist orientation toward dispensing of controlled substances and the people who obtain them. We conducted three mini focus groups. The focus group findings were used to inform the design of a structured survey. We emailed a survey to 160 pharmacists who were employed in one statewide community chain store; we obtained 48 survey responses. Focus groups findings suggested that, in relation to the dispensing of scheduled prescription medication, pharmacists were either "healthcare" oriented, "law-enforcement" oriented, or an orientation that combined these two perspectives. Surveys suggested that pharmacists found PDMPs easy to use and that they used them frequently - often to contact physicians directly. Surveys suggested that pharmacists were typically either "healthcare" oriented or "mixed" (combined perspectives). Pharmacist orientation was associated with the frequency with which they counseled patients about medication risk and the frequency with which they used the PDMP as the basis for contacting prescribers. Ongoing tracking of pharmacists' use of PDMPs is important both at the implementation stage and as PDMPs develop over time. The orientation construct developed here is useful in understanding pharmacist behavior and attitudes towards patients potentially at risk for misuse of controlled substance medications. Further research on this construct could shed light on barriers and incentives for pharmacist PDMP participation and use and provide guidance for pharmacist training, ultimately enhancing patient care.

  5. Vital and dispensable roles of Plasmodium multidrug resistance transporters during blood- and mosquito-stage development.

    Science.gov (United States)

    Rijpma, Sanna R; van der Velden, Maarten; Annoura, Takeshi; Matz, Joachim M; Kenthirapalan, Sanketha; Kooij, Taco W A; Matuschewski, Kai; van Gemert, Geert-Jan; van de Vegte-Bolmer, Marga; Siebelink-Stoter, Rianne; Graumans, Wouter; Ramesar, Jai; Klop, Onny; Russel, Frans G M; Sauerwein, Robert W; Janse, Chris J; Franke-Fayard, Blandine M; Koenderink, Jan B

    2016-07-01

    Multidrug resistance (MDR) proteins belong to the B subfamily of the ATP Binding Cassette (ABC) transporters, which export a wide range of compounds including pharmaceuticals. In this study, we used reverse genetics to study the role of all seven Plasmodium MDR proteins during the life cycle of malaria parasites. Four P. berghei genes (encoding MDR1, 4, 6 and 7) were refractory to deletion, indicating a vital role during blood stage multiplication and validating them as potential targets for antimalarial drugs. Mutants lacking expression of MDR2, MDR3 and MDR5 were generated in both P. berghei and P. falciparum, indicating a dispensable role for blood stage development. Whereas P. berghei mutants lacking MDR3 and MDR5 had a reduced blood stage multiplication in vivo, blood stage growth of P. falciparum mutants in vitro was not significantly different. Oocyst maturation and sporozoite formation in Plasmodium mutants lacking MDR2 or MDR5 was reduced. Sporozoites of these P. berghei mutants were capable of infecting mice and life cycle completion, indicating the absence of vital roles during liver stage development. Our results demonstrate vital and dispensable roles of MDR proteins during blood stages and an important function in sporogony for MDR2 and MDR5 in both Plasmodium species. © 2016 John Wiley & Sons Ltd.

  6. Barriers, motivators and enablers for dispensing multifocal contact lenses in Mumbai, India.

    Science.gov (United States)

    Thite, Nilesh; Shah, Ukti; Mehta, Jasmin; Jurkus, Janice

    2015-01-01

    To understand the potential barriers, motivators and enablers in dispensing multifocal contact lenses (MFCL). Two focus group discussions were conducted to design questionnaires regarding the prescribing habits for multifocal contact lenses (MFCL). Questions on potential barriers and motivators were included. The questionnaires were distributed among 133 eye care practitioners across Mumbai, India. Practitioners fitting one or less patient per month with MFCL completed the survey describing potential barriers, while those who prescribed more MFCL's per month completed the survey describing enablers and motivators. Responses from 102 practitioners were received. Most common potential barriers in prescribing MFCL were increased chair time (75%), lack of readily available trials (69%) and limitation in power range (63%). Lack of awareness among patients (90%) was the most common barrier from patients' outlook. Professional satisfaction (88%) and better business proposition (82%) were observed as main motivators while availability of the trials (84%) and correct patient selection (82%) were the major enablers. Graduate Optometrists felt dispensing MFCL did not offer a good business proposition (p=0.02). Experienced practitioners were observed to be least motivated (p=0.01) and believed that their patients found these lenses expensive (p=0.02). To enhance the MFCL practice, barriers like lack of awareness and limitations in power range must be addressed. Trial lens availability may motivate practitioners to prescribe MFCL. Further probing is required to understand lack of motivation among experienced practitioners. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  7. Prototype of a Questionnaire and Quiz System for Supporting Increase of Health Awareness During Wait Time in Dispensing Pharmacy

    Science.gov (United States)

    Toda, Takeshi; Chen, Poa-Min; Ozaki, Shinya; Ideguchi, Naoko; Miyaki, Tomoko; Nanbu, Keiko; Ikeda, Keiko

    For quit-smoking clinic and its campaign, there was a need for pharmacists to investigate pediatric patient's parent consciousness to tobacco harm utilizing wait time in a pediatric dispensing pharmacy. In this research, we developed the questionnaire and quiz total system using the tablet for user interface, in which people can easily answer the questionnaire/quiz and quickly see the total results on the spot in order to enhance their consciousness to the tobacco harm. The system also provides their tobacco dependence level based on the questionnaire results and some advice for their health and dietary habits due to the tobacco dependence level. From a field trial with one hundred four examinees in the pediatric dispensing pharmacy, the user interface was useful compared to conventional questionnaire form. The system could enhance their consciousness to tobacco harm and make their beneficial use of waiting time in dispensing pharmacy. Some interesting suggestions for improvement and new services were also obtained.

  8. Treatment practices of households and antibiotic dispensing in medicine outlets in developing countries: The case of Ghana

    DEFF Research Database (Denmark)

    Tersbøl, Britt Pinkowski

    2018-01-01

    in households and the antibiotic dispensing practices of medicine sales outlets in Eastern region, Ghana. Method: Twice-weekly illness recall visits were made to 12 households in three rural communities over eight consecutive weeks. Detailed fieldnotes were taken and analysed using a thematic approach....... Quantitative counts of health events and treatment were also conducted. Dispensing practices were systematically observed and documented in three rural and three urban medicine outlets for analysis. Result: Fever, abdominal, and respiratory symptoms were the most common causes of ill-health in the 12...... an integral part of healthcare in the study settings and the qualitative data provides a contextual understanding of over-the-counter antibiotic acquisition and use. Inappropriate antibiotic use is apparent in the study settings. Stricter regulation of the pharmaceutical sector, training of dispensers...

  9. A simple automated system for appetitive conditioning of zebrafish in their home tanks.

    Science.gov (United States)

    Doyle, Jillian M; Merovitch, Neil; Wyeth, Russell C; Stoyek, Matthew R; Schmidt, Michael; Wilfart, Florentin; Fine, Alan; Croll, Roger P

    2017-01-15

    We describe here an automated apparatus that permits rapid conditioning paradigms for zebrafish. Arduino microprocessors were used to control the delivery of auditory or visual stimuli to groups of adult or juvenile zebrafish in their home tanks in a conventional zebrafish facility. An automatic feeder dispensed precise amounts of food immediately after the conditioned stimuli, or at variable delays for controls. Responses were recorded using inexpensive cameras, with the video sequences analysed with ImageJ or Matlab. Fish showed significant conditioned responses in as few as 5 trials, learning that the conditioned stimulus was a predictor of food presentation at the water surface and at the end of the tank where the food was dispensed. Memories of these conditioned associations persisted for at least 2days after training when fish were tested either as groups or as individuals. Control fish, for which the auditory or visual stimuli were specifically unpaired with food, showed no comparable responses. This simple, low-cost, automated system permits scalable conditioning of zebrafish with minimal human intervention, greatly reducing both variability and labour-intensiveness. It will be useful for studies of the neural basis of learning and memory, and for high-throughput screening of compounds modifying those processes. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Controllable dose

    International Nuclear Information System (INIS)

    Alvarez R, J.T.; Anaya M, R.A.

    2004-01-01

    With the purpose of eliminating the controversy about the lineal hypothesis without threshold which found the systems of dose limitation of the recommendations of ICRP 26 and 60, at the end of last decade R. Clarke president of the ICRP proposed the concept of Controllable Dose: as the dose or dose sum that an individual receives from a particular source which can be reasonably controllable by means of any means; said concept proposes a change in the philosophy of the radiological protection of its concern by social approaches to an individual focus. In this work a panorama of the foundations is presented, convenient and inconveniences that this proposal has loosened in the international community of the radiological protection, with the purpose of to familiarize to our Mexican community in radiological protection with these new concepts. (Author)

  11. What do Australian consumers, pharmacists and prescribers think about documenting indications on prescriptions and dispensed medicines labels?: A qualitative study.

    Science.gov (United States)

    Garada, Mona; McLachlan, Andrew J; Schiff, Gordon D; Lehnbom, Elin C

    2017-11-15

    Documenting the indication on prescriptions and dispensed medicines labels is not standard practice in Australia. However, previous studies that have focused on the content and design of dispensed medicines labels, have suggested including the indication as a safety measure. The aim of this study was to investigate the perspectives of Australian consumers, pharmacists and prescribers on documenting the indication on prescriptions and dispensed medicines labels. Semi-structured interviews were conducted and mock-up of dispensed medicines labels were designed for participants. Consumers (n = 19) and pharmacists (n = 7) were recruited by convenience sample at community pharmacies in Sydney (Australia) and prescribers (n = 8), including two medical students, were recruited through snowballing. Thirty-four participants were interviewed. Most participants agreed that documenting the indication would be beneficial especially for patients who are forgetful or take multiple medications. Participants also believed it would improve consumers' medication understanding and adherence. Prescribers and pharmacists believed it could help reduce prescribing and dispensing errors by matching the drug/dosage to the correct indication. Prescribers refrained from documenting the indication to protect patients' privacy; however, most patients did not consider documenting the indication as a breach of privacy. Prescribers raised concerns about the extra time to include indications on prescriptions and best language to document indications, using plain language as opposed to medical terminology. All interviewed stakeholders identified numerous benefits of documenting the indication on prescriptions and dispensed medicines labels. Whether these potential benefits can be realized remains unknown and addressing prescribers' concern regarding the time involved in documenting the indication on prescriptions remains a challenge for vendors of electronic medication management systems.

  12. What do Australian consumers, pharmacists and prescribers think about documenting indications on prescriptions and dispensed medicines labels?: A qualitative study

    Directory of Open Access Journals (Sweden)

    Mona Garada

    2017-11-01

    Full Text Available Abstract Background Documenting the indication on prescriptions and dispensed medicines labels is not standard practice in Australia. However, previous studies that have focused on the content and design of dispensed medicines labels, have suggested including the indication as a safety measure. The aim of this study was to investigate the perspectives of Australian consumers, pharmacists and prescribers on documenting the indication on prescriptions and dispensed medicines labels. Methods Semi-structured interviews were conducted and mock-up of dispensed medicines labels were designed for participants. Consumers (n = 19 and pharmacists (n = 7 were recruited by convenience sample at community pharmacies in Sydney (Australia and prescribers (n = 8, including two medical students, were recruited through snowballing. Results Thirty-four participants were interviewed. Most participants agreed that documenting the indication would be beneficial especially for patients who are forgetful or take multiple medications. Participants also believed it would improve consumers’ medication understanding and adherence. Prescribers and pharmacists believed it could help reduce prescribing and dispensing errors by matching the drug/dosage to the correct indication. Prescribers refrained from documenting the indication to protect patients’ privacy; however, most patients did not consider documenting the indication as a breach of privacy. Prescribers raised concerns about the extra time to include indications on prescriptions and best language to document indications, using plain language as opposed to medical terminology. Conclusions All interviewed stakeholders identified numerous benefits of documenting the indication on prescriptions and dispensed medicines labels. Whether these potential benefits can be realized remains unknown and addressing prescribers’ concern regarding the time involved in documenting the indication on prescriptions

  13. Automation of Taxiing

    Directory of Open Access Journals (Sweden)

    Jaroslav Bursík

    2017-01-01

    Full Text Available The article focuses on the possibility of automation of taxiing, which is the part of a flight, which, under adverse weather conditions, greatly reduces the operational usability of an airport, and is the only part of a flight that has not been affected by automation, yet. Taxiing is currently handled manually by the pilot, who controls the airplane based on information from visual perception. The article primarily deals with possible ways of obtaining navigational information, and its automatic transfer to the controls. Analyzed wand assessed were currently available technologies such as computer vision, Light Detection and Ranging and Global Navigation Satellite System, which are useful for navigation and their general implementation into an airplane was designed. Obstacles to the implementation were identified, too. The result is a proposed combination of systems along with their installation into airplane’s systems so that it is possible to use the automated taxiing.

  14. Indigenous development of automated metallographic sample preparation system

    International Nuclear Information System (INIS)

    Kulkarni, A.P.; Pandit, K.M.; Deshmukh, A.G.; Sahoo, K.C.

    2005-01-01

    Surface preparation of specimens for Metallographic studies on irradiated material involves a lot of remote handling of radioactive material by skilled manpower. These are laborious and man-rem intensive activities and put limitations on number of samples that can be prepared for the metallographic studies. To overcome these limitations, automated systems have been developed for surface preparation of specimens in PIE division. The system includes (i) Grinding and polishing stations (ii) Water jet cleaning station (iii) Ultrasonic cleaning stations (iv) Drying station (v) Sample loading and unloading station (vi) Dispenser for slurries and diluents and (vii) Automated head for movement of the sample holder disc from one station to other. System facilities the operator for programming/changing sequence of the sample preparations including remote changing of grinding/polishing discs from the stations. Two such systems have been installed and commissioned in Hot Cell for PIE Division. These are being used for preparation of irradiated samples from nuclear fuels and structural components. This development has increased the throughput of metallography work and savings in terms of (man-severts) radiation exposure to operators. This presentation will provide details of the challenges in undertaking this developmental work. (author)

  15. Control and automation systems

    International Nuclear Information System (INIS)

    Schmidt, R.; Zillich, H.

    1986-01-01

    A survey is given of the development of control and automation systems for energy uses. General remarks about control and automation schemes are followed by a description of modern process control systems along with process control processes as such. After discussing the particular process control requirements of nuclear power plants the paper deals with the reliability and availability of process control systems and refers to computerized simulation processes. The subsequent paragraphs are dedicated to descriptions of the operating floor, ergonomic conditions, existing systems, flue gas desulfurization systems, the electromagnetic influences on digital circuits as well as of light wave uses. (HAG) [de

  16. Automated nuclear materials accounting

    International Nuclear Information System (INIS)

    Pacak, P.; Moravec, J.

    1982-01-01

    An automated state system of accounting for nuclear materials data was established in Czechoslovakia in 1979. A file was compiled of 12 programs in the PL/1 language. The file is divided into four groups according to logical associations, namely programs for data input and checking, programs for handling the basic data file, programs for report outputs in the form of worksheets and magnetic tape records, and programs for book inventory listing, document inventory handling and materials balance listing. A similar automated system of nuclear fuel inventory for a light water reactor was introduced for internal purposes in the Institute of Nuclear Research (UJV). (H.S.)

  17. Automating the CMS DAQ

    International Nuclear Information System (INIS)

    Bauer, G; Darlea, G-L; Gomez-Ceballos, G; Bawej, T; Chaze, O; Coarasa, J A; Deldicque, C; Dobson, M; Dupont, A; Gigi, D; Glege, F; Gomez-Reino, R; Hartl, C; Hegeman, J; Masetti, L; Behrens, U; Branson, J; Cittolin, S; Holzner, A; Erhan, S

    2014-01-01

    We present the automation mechanisms that have been added to the Data Acquisition and Run Control systems of the Compact Muon Solenoid (CMS) experiment during Run 1 of the LHC, ranging from the automation of routine tasks to automatic error recovery and context-sensitive guidance to the operator. These mechanisms helped CMS to maintain a data taking efficiency above 90% and to even improve it to 95% towards the end of Run 1, despite an increase in the occurrence of single-event upsets in sub-detector electronics at high LHC luminosity.

  18. Altering user' acceptance of automation through prior automation exposure.

    Science.gov (United States)

    Bekier, Marek; Molesworth, Brett R C

    2017-06-01

    Air navigation service providers worldwide see increased use of automation as one solution to overcome the capacity constraints imbedded in the present air traffic management (ATM) system. However, increased use of automation within any system is dependent on user acceptance. The present research sought to determine if the point at which an individual is no longer willing to accept or cooperate with automation can be manipulated. Forty participants underwent training on a computer-based air traffic control programme, followed by two ATM exercises (order counterbalanced), one with and one without the aid of automation. Results revealed after exposure to a task with automation assistance, user acceptance of high(er) levels of automation ('tipping point') decreased; suggesting it is indeed possible to alter automation acceptance. Practitioner Summary: This paper investigates whether the point at which a user of automation rejects automation (i.e. 'tipping point') is constant or can be manipulated. The results revealed after exposure to a task with automation assistance, user acceptance of high(er) levels of automation decreased; suggesting it is possible to alter automation acceptance.

  19. LIBRARY AUTOMATION IN NIGERAN UNIVERSITIES

    African Journals Online (AJOL)

    facilitate services and access to information in libraries is widely acceptable. ... Moreover, Ugah (2001) reports that the automation process at the. Abubakar ... blueprint in 1987 and a turn-key system of automation was suggested for the library.

  20. Automated system for review of radiotherapy treatment sheets

    International Nuclear Information System (INIS)

    Collado Chamorro, P.; Sanz Freire, C. J.; Vazquez Galinanes, A.; Diaz Pascual, V.; Gomez amez, J.; Martinez Sanchez, S.; Ossola Lentati, G. A.

    2011-01-01

    In many modern radiotherapy services begins to leaf treatment implemented in electronic form. In our department has developed an automated reporting system, that check the following parameters: treatment completed correctly, number of sessions and cumulative dose administered. Likewise treatments are verified in the allocated separate unit, and over-writing table parameters.

  1. Automated system for management of cementation line at Kursk NPP

    International Nuclear Information System (INIS)

    Petukhov, K.S.; Troshchenko, V.G.; Osintsev, V.V.; Molotkov, V.P.

    2005-01-01

    At Kursk NPP technological scheme of radioactive wastes tempering by dry cement mixture in continuously working mixer with continuous dosing of cement mixture components is accepted. The automated system designed for control and management of liquid radioactive wastes cementation in real time is represented [ru

  2. Future Trends in Process Automation

    OpenAIRE

    Jämsä-Jounela, Sirkka-Liisa

    2007-01-01

    The importance of automation in the process industries has increased dramatically in recent years. In the highly industrialized countries, process automation serves to enhance product quality, master the whole range of products, improve process safety and plant availability, efficiently utilize resources and lower emissions. In the rapidly developing countries, mass production is the main motivation for applying process automation. The greatest demand for process automation is in the chemical...

  3. Adaptive Automation Design and Implementation

    Science.gov (United States)

    2015-09-17

    with an automated system to a real-world adaptive au- tomation system implementation. There have been plenty of adaptive automation 17 Adaptive...of systems without increasing manpower requirements by allocating routine tasks to automated aids, improving safety through the use of au- tomated ...between intermediate levels of au- tomation , explicitly defining which human task a given level automates. Each model aids the creation and classification

  4. Care relationships at stake? Home healthcare professionals' experiences with digital medicine dispensers - a qualitative study.

    Science.gov (United States)

    Nakrem, Sigrid; Solbjør, Marit; Pettersen, Ida Nilstad; Kleiven, Hanne Hestvik

    2018-01-15

    Although digital technologies can mitigate the burdens of home healthcare services caused by an ageing population that lives at home longer with complex health problems, research on the impacts and consequences of digitalised remote communication between patients and caregivers is lacking. The present study explores how home healthcare professionals had experienced the introduction of digital medicine dispensers and their influence on patient-caregiver relationships. The multi-case study comprised semi-structured interviews with 21 healthcare professionals whose home healthcare service involved using the digital medicine dispensers. The constant comparative method was used for data analyses. Altogether, interviewed healthcare professionals reported three main technology-related impacts upon their patient-caregiver relationships. First, national and local pressure to increase efficiency had troubled their relationships with patients who suspected that municipalities have sought to lower costs by reducing and digitalising services. Participants reported having to consider such worries when introducing technologies into their services. Second, participants reported a shift towards empowering patients. Digital technology can empower patients who value their independence, whereas safety is more important for other patients. Healthcare professionals needed to ensure that replacing care tasks with technology implies safe and improved care. Third, the safety and quality of digital healthcare services continues to depend upon surveillance and control mechanisms that compensate for less face-to-face monitoring. Participants did not consider the possibility that surveillance exposes information about patients' everyday lives to be problematic, but to constitute opportunities for adjusting services to meet patients' needs. Technologies such as digital medicine dispensers can improve the efficiency of healthcare services and enhance patients' independence when introduced in a

  5. What proportion of prescription items dispensed in community pharmacies are eligible for the New Medicine Service?

    Science.gov (United States)

    Wells, Katharine M; Boyd, Matthew J; Thornley, Tracey; Boardman, Helen F

    2014-03-07

    The payment structure for the New Medicine Service (NMS) in England is based on the assumption that 0.5% of prescription items dispensed in community pharmacies are eligible for the service. This assumption is based on a theoretical calculation. This study aimed to find out the actual proportion of prescription items eligible for the NMS dispensed in community pharmacies in order to compare this with the theoretical assumption. The study also aimed to investigate whether the proportion of prescription items eligible for the NMS is affected by pharmacies' proximity to GP practices. The study collected data from eight pharmacies in Nottingham belonging to the same large chain of pharmacies. Pharmacies were grouped by distance from the nearest GP practice and sampled to reflect the distribution by distance of all pharmacies in Nottingham. Data on one thousand consecutive prescription items were collected from each pharmacy and the number of NMS eligible items recorded. All NHS prescriptions were included in the sample. Data were analysed and proportions calculated with 95% confidence intervals used to compare the study results against the theoretical figure of 0.5% of prescription items being eligible for the NMS. A total of 8005 prescription items were collected (a minimum of 1000 items per pharmacy) of which 17 items were eligible to receive the service. The study found that 0.25% (95% confidence intervals: 0.14% to 0.36%) of prescription items were eligible for the NMS which differs significantly from the theoretical assumption of 0.5%. The opportunity rate for the service was lower, 0.21% (95% confidence intervals: 0.10% to 0.32%) of items, as some items eligible for the NMS did not translate into opportunities to offer the service. Of all the prescription items collected in the pharmacies, 28% were collected by patient representatives. The results of this study show that the proportion of items eligible for the NMS dispensed in community pharmacies is lower than

  6. Refinement of Foam Backfill Technology for Expedient Airfield Damage Repair; Phase 2: Development of Prototype Foam Dispensing Equipment and Improved Tactics, Techniques and Procedures

    Science.gov (United States)

    2017-12-01

    ER D C TR -1 7- 14 U.S. Air Force Rapid Airfield Damage Repair Modernization Program Refinement of Foam Backfill Technology for...Backfill Technology for Expedient Airfield Damage Repair Phase II: Development of Prototype Foam Dispensing Equipment and Improved Tactics...procedures (TTPs) for rapid airfield damage repair (RADR) using foam backfill technology . Three different prototype foam dispensing systems were

  7. Randomized crossover study evaluating the effect of a hand sanitizer dispenser on the frequency of hand hygiene among anesthesiology staff in the operating room.

    Science.gov (United States)

    Munoz-Price, L Silvia; Patel, Zalak; Banks, Shawn; Arheart, Kristopher; Eber, Scott; Lubarsky, David A; Birnbach, David J

    2014-06-01

    Forty anesthesia providers were evaluated with and without hand sanitizer dispensers present on the anesthesia machine. Having a dispenser increased the frequency of hand hygiene only from 0.5 to 0.8 events per hour (P = .01). Other concomitant interventions are needed to further increase hand hygiene frequency among anesthesia providers.

  8. Automated HAZOP revisited

    DEFF Research Database (Denmark)

    Taylor, J. R.

    2017-01-01

    Hazard and operability analysis (HAZOP) has developed from a tentative approach to hazard identification for process plants in the early 1970s to an almost universally accepted approach today, and a central technique of safety engineering. Techniques for automated HAZOP analysis were developed...

  9. Automated Student Model Improvement

    Science.gov (United States)

    Koedinger, Kenneth R.; McLaughlin, Elizabeth A.; Stamper, John C.

    2012-01-01

    Student modeling plays a critical role in developing and improving instruction and instructional technologies. We present a technique for automated improvement of student models that leverages the DataShop repository, crowd sourcing, and a version of the Learning Factors Analysis algorithm. We demonstrate this method on eleven educational…

  10. Automated Vehicle Monitoring System

    OpenAIRE

    Wibowo, Agustinus Deddy Arief; Heriansyah, Rudi

    2014-01-01

    An automated vehicle monitoring system is proposed in this paper. The surveillance system is based on image processing techniques such as background subtraction, colour balancing, chain code based shape detection, and blob. The proposed system will detect any human's head as appeared at the side mirrors. The detected head will be tracked and recorded for further action.

  11. Mechatronic Design Automation

    DEFF Research Database (Denmark)

    Fan, Zhun

    successfully design analogue filters, vibration absorbers, micro-electro-mechanical systems, and vehicle suspension systems, all in an automatic or semi-automatic way. It also investigates the very important issue of co-designing plant-structures and dynamic controllers in automated design of Mechatronic...

  12. Automated Accounting. Instructor Guide.

    Science.gov (United States)

    Moses, Duane R.

    This curriculum guide was developed to assist business instructors using Dac Easy Accounting College Edition Version 2.0 software in their accounting programs. The module consists of four units containing assignment sheets and job sheets designed to enable students to master competencies identified in the area of automated accounting. The first…

  13. Automated conflict resolution issues

    Science.gov (United States)

    Wike, Jeffrey S.

    1991-01-01

    A discussion is presented of how conflicts for Space Network resources should be resolved in the ATDRSS era. The following topics are presented: a description of how resource conflicts are currently resolved; a description of issues associated with automated conflict resolution; present conflict resolution strategies; and topics for further discussion.

  14. Automated gamma counters

    International Nuclear Information System (INIS)

    Regener, M.

    1977-01-01

    This is a report on the most recent developments in the full automation of gamma counting in RIA, in particular by Messrs. Kontron. The development targets were flexibility in sample capacity and shape of test tubes, the possibility of using different radioisotopes for labelling due to an optimisation of the detector system and the use of microprocessers to substitute software for hardware. (ORU) [de

  15. Myths in test automation

    Directory of Open Access Journals (Sweden)

    Jazmine Francis

    2014-12-01

    Full Text Available Myths in automation of software testing is an issue of discussion that echoes about the areas of service in validation of software industry. Probably, the first though that appears in knowledgeable reader would be Why this old topic again? What's New to discuss the matter? But, for the first time everyone agrees that undoubtedly automation testing today is not today what it used to be ten or fifteen years ago, because it has evolved in scope and magnitude. What began as a simple linear scripts for web applications today has a complex architecture and a hybrid framework to facilitate the implementation of testing applications developed with various platforms and technologies. Undoubtedly automation has advanced, but so did the myths associated with it. The change in perspective and knowledge of people on automation has altered the terrain. This article reflects the points of views and experience of the author in what has to do with the transformation of the original myths in new versions, and how they are derived; also provides his thoughts on the new generation of myths.

  16. Myths in test automation

    Directory of Open Access Journals (Sweden)

    Jazmine Francis

    2015-01-01

    Full Text Available Myths in automation of software testing is an issue of discussion that echoes about the areas of service in validation of software industry. Probably, the first though that appears in knowledgeable reader would be Why this old topic again? What's New to discuss the matter? But, for the first time everyone agrees that undoubtedly automation testing today is not today what it used to be ten or fifteen years ago, because it has evolved in scope and magnitude. What began as a simple linear scripts for web applications today has a complex architecture and a hybrid framework to facilitate the implementation of testing applications developed with various platforms and technologies. Undoubtedly automation has advanced, but so did the myths associated with it. The change in perspective and knowledge of people on automation has altered the terrain. This article reflects the points of views and experience of the author in what has to do with the transformation of the original myths in new versions, and how they are derived; also provides his thoughts on the new generation of myths.

  17. Building Automation Systems.

    Science.gov (United States)

    Honeywell, Inc., Minneapolis, Minn.

    A number of different automation systems for use in monitoring and controlling building equipment are described in this brochure. The system functions include--(1) collection of information, (2) processing and display of data at a central panel, and (3) taking corrective action by sounding alarms, making adjustments, or automatically starting and…

  18. Automation of activation analysis

    International Nuclear Information System (INIS)

    Ivanov, I.N.; Ivanets, V.N.; Filippov, V.V.

    1985-01-01

    The basic data on the methods and equipment of activation analysis are presented. Recommendations on the selection of activation analysis techniques, and especially the technique envisaging the use of short-lived isotopes, are given. The equipment possibilities to increase dataway carrying capacity, using modern computers for the automation of the analysis and data processing procedure, are shown

  19. Protokoller til Home Automation

    DEFF Research Database (Denmark)

    Kjær, Kristian Ellebæk

    2008-01-01

    computer, der kan skifte mellem foruddefinerede indstillinger. Nogle gange kan computeren fjernstyres over internettet, så man kan se hjemmets status fra en computer eller måske endda fra en mobiltelefon. Mens nævnte anvendelser er klassiske indenfor home automation, er yderligere funktionalitet dukket op...

  20. Automation of radioimmunoassays

    International Nuclear Information System (INIS)

    Goldie, D.J.; West, P.M.; Ismail, A.A.A.

    1979-01-01

    A short account is given of recent developments in automation of the RIA technique. Difficulties encountered in the incubation, separation and quantitation steps are summarized. Published references are given to a number of systems, both discrete and continuous flow, and details are given of a system developed by the present authors. (U.K.)

  1. Microcontroller for automation application

    Science.gov (United States)

    Cooper, H. W.

    1975-01-01

    The description of a microcontroller currently being developed for automation application was given. It is basically an 8-bit microcomputer with a 40K byte random access memory/read only memory, and can control a maximum of 12 devices through standard 15-line interface ports.

  2. Driver Psychology during Automated Platooning

    NARCIS (Netherlands)

    Heikoop, D.D.

    2017-01-01

    With the rapid increase in vehicle automation technology, the call for understanding how humans behave while driving in an automated vehicle becomes more urgent. Vehicles that have automated systems such as Lane Keeping Assist (LKA) or Adaptive Cruise Control (ACC) not only support drivers in their

  3. Automating spectral measurements

    Science.gov (United States)

    Goldstein, Fred T.

    2008-09-01

    This paper discusses the architecture of software utilized in spectroscopic measurements. As optical coatings become more sophisticated, there is mounting need to automate data acquisition (DAQ) from spectrophotometers. Such need is exacerbated when 100% inspection is required, ancillary devices are utilized, cost reduction is crucial, or security is vital. While instrument manufacturers normally provide point-and-click DAQ software, an application programming interface (API) may be missing. In such cases automation is impossible or expensive. An API is typically provided in libraries (*.dll, *.ocx) which may be embedded in user-developed applications. Users can thereby implement DAQ automation in several Windows languages. Another possibility, developed by FTG as an alternative to instrument manufacturers' software, is the ActiveX application (*.exe). ActiveX, a component of many Windows applications, provides means for programming and interoperability. This architecture permits a point-and-click program to act as automation client and server. Excel, for example, can control and be controlled by DAQ applications. Most importantly, ActiveX permits ancillary devices such as barcode readers and XY-stages to be easily and economically integrated into scanning procedures. Since an ActiveX application has its own user-interface, it can be independently tested. The ActiveX application then runs (visibly or invisibly) under DAQ software control. Automation capabilities are accessed via a built-in spectro-BASIC language with industry-standard (VBA-compatible) syntax. Supplementing ActiveX, spectro-BASIC also includes auxiliary serial port commands for interfacing programmable logic controllers (PLC). A typical application is automatic filter handling.

  4. Centrioles initiate cilia assembly but are dispensable for maturation and maintenance in C. elegans.

    Science.gov (United States)

    Serwas, Daniel; Su, Tiffany Y; Roessler, Max; Wang, Shaohe; Dammermann, Alexander

    2017-06-05

    Cilia are cellular projections that assemble on centriole-derived basal bodies. While cilia assembly is absolutely dependent on centrioles, it is not known to what extent they contribute to downstream events. The nematode C. elegans provides a unique opportunity to address this question, as centrioles do not persist at the base of mature cilia. Using fluorescence microscopy and electron tomography, we find that centrioles degenerate early during ciliogenesis. The transition zone and axoneme are not completely formed at this time, indicating that cilia maturation does not depend on intact centrioles. The hydrolethalus syndrome protein HYLS-1 is the only centriolar protein known to remain at the base of mature cilia and is required for intraflagellar transport trafficking. Surprisingly, targeted degradation of HYLS-1 after initiation of ciliogenesis does not affect ciliary structures. Taken together, our results indicate that while centrioles are essential to initiate cilia formation, they are dispensable for cilia maturation and maintenance. © 2017 Serwas et al.

  5. Method and apparatus for dispensing small quantities of mercury from evacuated and sealed glass capsules

    Science.gov (United States)

    Grossman, Mark W.; George, William A.; Pai, Robert Y.

    1985-01-01

    A technique for opening an evacuated and sealed glass capsule containing a material that is to be dispensed which has a relatively high vapor pressure such as mercury. The capsule is typically disposed in a discharge tube envelope. The technique involves the use of a first light source imaged along the capsule and a second light source imaged across the capsule substantially transversely to the imaging of the first light source. Means are provided for constraining a segment of the capsule along its length with the constraining means being positioned to correspond with the imaging of the second light source. These light sources are preferably incandescent projection lamps. The constraining means is preferably a multiple looped wire support.

  6. Lipid Droplet Formation Is Dispensable for Endoplasmic Reticulum-associated Degradation*

    Science.gov (United States)

    Olzmann, James A.; Kopito, Ron R.

    2011-01-01

    Proteins that fail to fold or assemble in the endoplasmic reticulum (ER) are destroyed by cytoplasmic proteasomes through a process known as ER-associated degradation. Substrates of this pathway are initially sequestered within the ER lumen and must therefore be dislocated across the ER membrane to be degraded. It has been proposed that generation of bicellar structures during lipid droplet formation may provide an “escape hatch” through which misfolded proteins, toxins, and viruses can exit the ER. We have directly tested this hypothesis by exploiting yeast strains defective in lipid droplet formation. Our data demonstrate that lipid droplet formation is dispensable for the dislocation of a plant toxin and the degradation of both soluble and integral membrane glycoproteins. PMID:21693705

  7. Solvent removal and spore inactivation directly in dispensing vials with supercritical carbon dioxide and sterilant.

    Science.gov (United States)

    Howell, Jahna; Niu, Fengui; McCabe, Shannon E; Zhou, Wei; Decedue, Charles J

    2012-06-01

    A process is described using supercritical carbon dioxide to extract organic solvents from drug solutions contained in 30-mL serum vials. We report drying times of less than 1 h with quantitative recovery of sterile drug. A six-log reduction of three spore types used as biological indicators is achieved with direct addition of peracetic acid to a final concentration of approximately 5 mM (~0.04 %) to the drug solution in the vial. Analysis of two drugs, acetaminophen and paclitaxel, indicated no drug degradation as a result of the treatment. Furthermore, analysis of the processed drug substance showed that no residual peracetic acid could be detected in the final product. We have demonstrated an effective means to simultaneously dry and sterilize active pharmaceutical ingredients from organic solvents directly in a dispensing container.

  8. Acetyl CoA Carboxylase 2 Is Dispensable for CD8+ T Cell Responses.

    Directory of Open Access Journals (Sweden)

    Jang Eun Lee

    Full Text Available Differentiation of T cells is closely associated with dynamic changes in nutrient and energy metabolism. However, the extent to which specific metabolic pathways and molecular components are determinative of CD8+ T cell fate remains unclear. It has been previously established in various tissues that acetyl CoA carboxylase 2 (ACC2 regulates fatty acid oxidation (FAO by inhibiting carnitine palmitoyltransferase 1 (CPT1, a rate-limiting enzyme of FAO in mitochondria. Here, we explore the cell-intrinsic role of ACC2 in T cell immunity in response to infections. We report here that ACC2 deficiency results in a marginal increase of cellular FAO in CD8+ T cells, but does not appear to influence antigen-specific effector and memory CD8+ T cell responses during infection with listeria or lymphocytic choriomeningitis virus. These results suggest that ACC2 is dispensable for CD8+ T cell responses.

  9. Catch-slip bonds can be dispensable for motor force regulation during skeletal muscle contraction

    Science.gov (United States)

    Dong, Chenling; Chen, Bin

    2015-07-01

    It is intriguing how multiple molecular motors can perform coordinated and synchronous functions, which is essential in various cellular processes. Recent studies on skeletal muscle might have shed light on this issue, where rather precise motor force regulation was partly attributed to the specific stochastic features of a single attached myosin motor. Though attached motors can randomly detach from actin filaments either through an adenosine triphosphate (ATP) hydrolysis cycle or through "catch-slip bond" breaking, their respective contribution in motor force regulation has not been clarified. Here, through simulating a mechanical model of sarcomere with a coupled Monte Carlo method and finite element method, we find that the stochastic features of an ATP hydrolysis cycle can be sufficient while those of catch-slip bonds can be dispensable for motor force regulation.

  10. Rac1 in muscle is dispensable for improved insulin action after exercise in mice

    DEFF Research Database (Denmark)

    Sylow, Lykke; Møller, Lisbeth Liliendal Valbjørn; D'Hulst, Gommaar

    2016-01-01

    sensitivity in inducible muscle-specific Rac1 knockout (mKO) and wildtype littermate (WT) mice. Prior exercise enhanced whole body insulin sensitivity by 40% in WT mice and rescued the insulin intolerance in Rac1 mKO mice by improving whole body insulin sensitivity by 230%. In agreement, prior exercise...... significantly improved insulin sensitivity by 20% in WT and by 40% in Rac1 mKO soleus muscles. These findings suggest that muscle Rac1 is dispensable for the insulin sensitizing effect of exercise. Moreover, insulin resistance in Rac1 mKO mice can be completely normalized by prior exercise explaining why......Exercise has a potent insulin-sensitivity enhancing effect on skeletal muscle but the intracellular mechanisms that mediate this effect are not well understood. In muscle, Rac1 regulates both insulin- and contraction-stimulated glucose transport and is dysregulated in insulin resistant muscle...

  11. Investigation of Influence of Surface Nanoparticle on Emission Properties of Scandia-Doped Dispenser Cathodes

    Science.gov (United States)

    Zhang, Xizhu; Wang, Jinshu; Wang, Yiman; Liu, Wei; Zhou, Meiling; Gao, Zhiyuan

    2013-06-01

    The microstructure of a fully activated scandia doped dispenser (SDD) cathode has been studied by scanning electron microscope (SEM). The observation results display that nanoparticles appear at the growth steps and the surface of tungsten grains of the fully activated SDD cathode. To study the influence of the nanoparticles on the emission, the local electric field strengths around the nanoparticles have been calculated by Maxwell 2D code and Comsol. The calculation results show that the local electric field strengths are enhanced by 1.1 to 3.8 times to average value based on different model conditions. The highest field strength is about 1.54 × 105 V/cm at an average field strength of 40 KV/cm, which is related to a space-charge limited (SCL) current density of 100 A/cm2 in the experimental configuration. This implies the field strength is not high enough to cause field emission.

  12. Fast switching of alkali atom dispensers using laser-induced heating

    International Nuclear Information System (INIS)

    Griffin, P.F.; Weatherill, K.J.; Adams, C.S.

    2005-01-01

    We show that by using an intense laser source to locally heat an alkali atom dispenser, one can generate a high flux of atoms followed by fast recovery (<100 ms) of the background pressure when the laser is extinguished. For repeated heating pulses a switch-on time for the atomic flux of 200 ms is readily attainable. This technique is suited to ultracold atom experiments using simple ultrahigh vacuum (UHV) chambers. Laser-induced heating provides a fast repetition of the experimental cycle, which, combined with low atom loss due to background gas collisions, is particularly useful for experiments involving far-off resonance optical traps, where sufficient laser power (0.5-4 W) is readily available

  13. Hydrogen Station Compression, Storage, and Dispensing Technical Status and Costs: Systems Integration

    Energy Technology Data Exchange (ETDEWEB)

    Parks, G.; Boyd, R.; Cornish, J.; Remick, R.

    2014-05-01

    At the request of the U.S. Department of Energy Fuel Cell Technologies Office (FCTO), the National Renewable Energy Laboratory commissioned an independent review of hydrogen compression, storage, and dispensing (CSD) for pipeline delivery of hydrogen and forecourt hydrogen production. The panel was asked to address the (1) cost calculation methodology, (2) current cost/technical status, (3) feasibility of achieving the FCTO's 2020 CSD levelized cost targets, and to (4) suggest research areas that will help the FCTO reach its targets. As the panel neared the completion of these tasks, it was also asked to evaluate CSD costs for the delivery of hydrogen by high-pressure tube trailer. This report details these findings.

  14. Printed droplet microfluidics for on demand dispensing of picoliter droplets and cells.

    Science.gov (United States)

    Cole, Russell H; Tang, Shi-Yang; Siltanen, Christian A; Shahi, Payam; Zhang, Jesse Q; Poust, Sean; Gartner, Zev J; Abate, Adam R

    2017-08-15

    Although the elementary unit of biology is the cell, high-throughput methods for the microscale manipulation of cells and reagents are limited. The existing options either are slow, lack single-cell specificity, or use fluid volumes out of scale with those of cells. Here we present printed droplet microfluidics, a technology to dispense picoliter droplets and cells with deterministic control. The core technology is a fluorescence-activated droplet sorter coupled to a specialized substrate that together act as a picoliter droplet and single-cell printer, enabling high-throughput generation of intricate arrays of droplets, cells, and microparticles. Printed droplet microfluidics provides a programmable and robust technology to construct arrays of defined cell and reagent combinations and to integrate multiple measurement modalities together in a single assay.

  15. Elongation factor P is dispensable in Escherichia coli and Pseudomonas aeruginosa.

    Science.gov (United States)

    Balibar, Carl J; Iwanowicz, Dorothy; Dean, Charles R

    2013-09-01

    Elongation factor P (EF-P) is a highly conserved ribosomal initiation factor responsible for stimulating formation of the first peptide bond. Its essentiality has been debated and may differ depending on the organism. Here, we demonstrate that EF-P is dispensable in Escherichia coli and Pseudomonas aeruginosa under laboratory growth conditions. Although knockouts are viable, growth rates are diminished compared with wild-type strains. Despite this cost in fitness, these mutants are not more susceptible to a wide range of antibiotics; including ribosome targeting antibiotics, such as lincomycin, chloramphenicol, and streptomycin, which have been shown previously to disrupt EF-P function in vitro. In Pseudomonas, knockout of efp leads to an upregulation of mexX, a phenotype previously observed with other genetic lesions affecting ribosome function and that can be induced by the treatment with antibiotics affecting protein synthesis.

  16. ASCIZ/ATMIN is dispensable for ATM signaling in response to replication stress.

    Science.gov (United States)

    Liu, Rui; King, Ashleigh; Hoch, Nicolas C; Chang, Catherine; Kelly, Gemma L; Deans, Andrew J; Heierhorst, Jörg

    2017-09-01

    The ATM kinase plays critical roles in the response to DNA double-strand breaks, and can also be activated by prolonged DNA replication blocks. It has recently been proposed that replication stress-dependent ATM activation is mediated by ASCIZ (also known as ATMIN, ZNF822), an essential developmental transcription factor. In contrast, we show here that ATM activation, and phosphorylation of its substrates KAP1, p53 and H2AX in response to the replication blocking agent aphidicolin was unaffected in both immortalized and primary ASCIZ/ATMIN-deficient murine embryonic fibroblasts compared to control cells. Similar results were also obtained in human ASCIZ/ATMIN-deleted lymphoma cells. The results demonstrate that ASCIZ/ATMIN is dispensable for ATM activation, and contradict the previously reported dependence of ATM on ASCIZ/ATMIN. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  17. Studies on the pressed yttrium oxide-tungsten matrix as a possible dispenser cathode material

    International Nuclear Information System (INIS)

    Yang, Fan; Wang, Jinshu; Liu, Wei; Liu, Xiang; Zhou, Meiling

    2015-01-01

    Yttrium oxide was chosen as the secondary emission substance based on calculation results through first principle theory method. A new kind of pressed yttrium oxide-tungsten matrix dispenser cathodes are prepared by a sol–gel method combined with high temperature sintering in dry hydrogen atmosphere. The results show that the growth of the grains is hampered by the pinning effect of Y 2 O 3 distributing uniformly between the tungsten particles, resulting in the formation of small grain size. It is found that Y 2 O 3 improves the secondary electron emission property, i.e., the secondary emission yield increases with the increase of Y 2 O 3 content in the samples. The maximum secondary emission yield δ max of the cathode with 15% amount of Y 2 O 3 can reach 2.92. Furthermore, the cathode shows a certain thermionic emission performance. The zero field emission current density J 0 of 4.18A/cm 2 has reached at 1050 °C b for this kind of cathode after being activated at 1200 °C b , which are much higher than that of rare earth oxide doped molybdenum (REO-Mo) cathode reported in the previous work. - Highlights: • Yttrium oxide was chosen as the secondary emission substance based on first principle calculation result. • A new kind of cathode has been successfully obtained. • Pressed yttrium oxide-tungsten matrix dispenser cathode exhibits good emission properties. • The improvement of the cathode emission can be well explained by the surface analysis results presented in this work

  18. Studies on the pressed yttrium oxide-tungsten matrix as a possible dispenser cathode material

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Fan; Wang, Jinshu, E-mail: wangjsh@bjut.edu.cn; Liu, Wei; Liu, Xiang; Zhou, Meiling

    2015-01-15

    Yttrium oxide was chosen as the secondary emission substance based on calculation results through first principle theory method. A new kind of pressed yttrium oxide-tungsten matrix dispenser cathodes are prepared by a sol–gel method combined with high temperature sintering in dry hydrogen atmosphere. The results show that the growth of the grains is hampered by the pinning effect of Y{sub 2}O{sub 3} distributing uniformly between the tungsten particles, resulting in the formation of small grain size. It is found that Y{sub 2}O{sub 3} improves the secondary electron emission property, i.e., the secondary emission yield increases with the increase of Y{sub 2}O{sub 3} content in the samples. The maximum secondary emission yield δ{sub max} of the cathode with 15% amount of Y{sub 2}O{sub 3} can reach 2.92. Furthermore, the cathode shows a certain thermionic emission performance. The zero field emission current density J{sub 0} of 4.18A/cm{sup 2} has reached at 1050 °C{sub b} for this kind of cathode after being activated at 1200 °C{sub b}, which are much higher than that of rare earth oxide doped molybdenum (REO-Mo) cathode reported in the previous work. - Highlights: • Yttrium oxide was chosen as the secondary emission substance based on first principle calculation result. • A new kind of cathode has been successfully obtained. • Pressed yttrium oxide-tungsten matrix dispenser cathode exhibits good emission properties. • The improvement of the cathode emission can be well explained by the surface analysis results presented in this work.

  19. Comparison of Batch Assay and Random Assay Using Automatic Dispenser in Radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Seung Hwan; Jang, Su Jin; Kang, Ji Yeon; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul [Seoul Metropolitan Government Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Lee, Ho Young; Shin, Sun Young; Min, Gyeong Sun; Lee, Hyun Joo [Seoul National University college of Medicine, Seoul (Korea, Republic of)

    2009-08-15

    Radioimmunoassay (RIA) was usually performed by the batch assay. To improve the efficiency of RIA without increase of the cost and time, random assay could be a choice. We investigated the possibility of the random assay using automatic dispenser by assessing the agreement between batch assay and random assay. The experiments were performed with four items; Triiodothyronine (T3), free thyroxine (fT4), Prostate specific antigen (PSA), Carcinoembryonic antigen (CEA). In each item, the sera of twenty patients, the standard, and the control samples were used. The measurements were done 4 times with 3 hour time intervals by random assay and batch assay. The coefficient of variation (CV) of the standard samples and patients' data in T3, fT4, PSA, and CEA were assessed. ICC (Intraclass correlation coefficient) and coefficient of correlation were measured to assessing the agreement between two methods. The CVs (%) of T3, fT4, PSA, and CEA measured by batch assay were 3.2+-1.7%, 3.9+-2.1%, 7.1+-6.2%, 11.2+-7.2%. The CVs by random assay were 2.1+-1.7%, 4.8+-3.1%, 3.6+-4.8%, and 7.4+-6.2%. The ICC between the batch assay and random assay were 0.9968 (T3), 0.9973 (fT4), 0.9996 (PSA), and 0.9901 (CEA). The coefficient of correlation between the batch assay and random assay were 0.9924(T3), 0.9974 (fT4), 0.9994 (PSA), and 0.9989 (CEA) (p<0.05). The results of random assay showed strong agreement with the batch assay in a day. These results suggest that random assay using automatic dispenser could be used in radioimmunoassay

  20. Comparison of Batch Assay and Random Assay Using Automatic Dispenser in Radioimmunoassay

    International Nuclear Information System (INIS)

    Moon, Seung Hwan; Jang, Su Jin; Kang, Ji Yeon; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul; Lee, Ho Young; Shin, Sun Young; Min, Gyeong Sun; Lee, Hyun Joo

    2009-01-01

    Radioimmunoassay (RIA) was usually performed by the batch assay. To improve the efficiency of RIA without increase of the cost and time, random assay could be a choice. We investigated the possibility of the random assay using automatic dispenser by assessing the agreement between batch assay and random assay. The experiments were performed with four items; Triiodothyronine (T3), free thyroxine (fT4), Prostate specific antigen (PSA), Carcinoembryonic antigen (CEA). In each item, the sera of twenty patients, the standard, and the control samples were used. The measurements were done 4 times with 3 hour time intervals by random assay and batch assay. The coefficient of variation (CV) of the standard samples and patients' data in T3, fT4, PSA, and CEA were assessed. ICC (Intraclass correlation coefficient) and coefficient of correlation were measured to assessing the agreement between two methods. The CVs (%) of T3, fT4, PSA, and CEA measured by batch assay were 3.2±1.7%, 3.9±2.1%, 7.1±6.2%, 11.2±7.2%. The CVs by random assay were 2.1±1.7%, 4.8±3.1%, 3.6±4.8%, and 7.4±6.2%. The ICC between the batch assay and random assay were 0.9968 (T3), 0.9973 (fT4), 0.9996 (PSA), and 0.9901 (CEA). The coefficient of correlation between the batch assay and random assay were 0.9924(T3), 0.9974 (fT4), 0.9994 (PSA), and 0.9989 (CEA) (p<0.05). The results of random assay showed strong agreement with the batch assay in a day. These results suggest that random assay using automatic dispenser could be used in radioimmunoassay

  1. 21 CFR 369.3 - Warnings required on drugs exempted from prescription-dispensing requirements of section 503(b)(1...

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Warnings required on drugs exempted from prescription-dispensing requirements of section 503(b)(1)(C). 369.3 Section 369.3 Food and Drugs FOOD AND DRUG... subject to the labeling requirements prescribed in § 310.201(a) of this chapter. Although, for convenience...

  2. 75 FR 28651 - In the Matter of Certain Electronic Paper Towel Dispensing Devices and Components Thereof; Notice...

    Science.gov (United States)

    2010-05-21

    ... INTERNATIONAL TRADE COMMISSION [Inv. No. 337-TA-718] In the Matter of Certain Electronic Paper Towel Dispensing Devices and Components Thereof; Notice of Investigation AGENCY: International Trade... that a complaint was filed with the U.S. International Trade Commission on April 19, 2010, under...

  3. 21 CFR 1300.04 - Definitions relating to the dispensing of controlled substances by means of the Internet.

    Science.gov (United States)

    2010-04-01

    ... controlled substances by means of the Internet. 1300.04 Section 1300.04 Food and Drugs DRUG ENFORCEMENT... substances by means of the Internet. (a) Any term not defined in this part or elsewhere in this chapter shall... evaluation of the patient. (c) The term deliver, distribute, or dispense by means of the Internet refers...

  4. Dose and dose rate monitor

    International Nuclear Information System (INIS)

    Novakova, O.; Ryba, J.; Slezak, V.; Svobodova, B.; Viererbl, L.

    1984-10-01

    The methods are discussea of measuring dose rate or dose using a scintillation counte. A plastic scintillator based on polystyrene with PBD and POPOP activators and coated with ZnS(Ag) was chosen for the projected monitor. The scintillators were cylindrical and spherical in shape and of different sizes; black polypropylene tubes were chosen as the best case for the probs. For the counter with different plastic scintillators, the statistical error 2σ for natural background was determined. For determining the suitable thickness of the ZnS(Ag) layer the energy dependence of the counter was measured. Radioisotopes 137 Cs, 241 Am and 109 Cd were chosen as radiation sources. The best suited ZnS(Ag) thickness was found to be 0.5 μm. Experiments were carried out to determine the directional dependence of the detector response and the signal to noise ratio. The temperature dependence of the detector response and its compensation were studied, as were the time stability and fatigue manifestations of the photomultiplier. The design of a laboratory prototype of a dose rate and dose monitor is described. Block diagrams are given of the various functional parts of the instrument. The designed instrument is easiiy portable, battery powered, measures dose rates from natural background in the range of five orders, i.e., 10 -2 to 10 3 nGy/s, and allows to determine a dose of up to 10 mGy. Accouracy of measurement in the energy range of 50 keV to 1 MeV is better than +-20%. (E.S.)

  5. Design of a new non-sterile glove-dispensing unit to reduce touch-based contamination

    Directory of Open Access Journals (Sweden)

    Jennifer R Amos

    2014-06-01

    Full Text Available Background Despite best efforts by healthcare providers to sterilise their hands through hand washing prior to touching medical equipment and patients, bacteria are still present and can be spread through physical contact. We aimed to reduce the spread of touch-induced and airborne bacteria and virus spreading by using a touch-free glove-dispensing system that minimally exposes gloves in the box to air. Method The team met multiple times to undertake early prototyping and present ideas for the design. We experimented with folding gloves in varying patterns, similar to facial tissue-dispensing boxes, and tried several methods of opening/closing the glove box to determine the most effective way to access gloves with the least amount of physical contact. We considered the user experience and obtained user feedback after each design iteration. Results Ultimately, we decided on a vertically oriented box with optional holes for dispensing a glove on the side of the box or on the bottom by means of the pull-down drawer mechanism. This system will dispense a single glove at a time to the user with the option of using a pull-down drawer trigger to decrease the likelihood of physical contact with unused gloves. Both methods dispense a single glove. Conclusion: By reducing physical contact between the healthcare practitioner and the gloves, we are potentially reducing the spread of bacteria. This glove box design ensures that gloves are not exposed to the air in the clinic or hospital setting, thereby further reducing spread of airborne germs. This could assist in decreasing the risk of nosocomial infections in healthcare settings.

  6. Rapid automated nuclear chemistry

    International Nuclear Information System (INIS)

    Meyer, R.A.

    1979-01-01

    Rapid Automated Nuclear Chemistry (RANC) can be thought of as the Z-separation of Neutron-rich Isotopes by Automated Methods. The range of RANC studies of fission and its products is large. In a sense, the studies can be categorized into various energy ranges from the highest where the fission process and particle emission are considered, to low energies where nuclear dynamics are being explored. This paper presents a table which gives examples of current research using RANC on fission and fission products. The remainder of this text is divided into three parts. The first contains a discussion of the chemical methods available for the fission product elements, the second describes the major techniques, and in the last section, examples of recent results are discussed as illustrations of the use of RANC

  7. Automated optical assembly

    Science.gov (United States)

    Bala, John L.

    1995-08-01

    Automation and polymer science represent fundamental new technologies which can be directed toward realizing the goal of establishing a domestic, world-class, commercial optics business. Use of innovative optical designs using precision polymer optics will enable the US to play a vital role in the next generation of commercial optical products. The increased cost savings inherent in the utilization of optical-grade polymers outweighs almost every advantage of using glass for high volume situations. Optical designers must gain experience with combined refractive/diffractive designs and broaden their knowledge base regarding polymer technology beyond a cursory intellectual exercise. Implementation of a fully automated assembly system, combined with utilization of polymer optics, constitutes the type of integrated manufacturing process which will enable the US to successfully compete with the low-cost labor employed in the Far East, as well as to produce an equivalent product.

  8. Automated breeder fuel fabrication

    International Nuclear Information System (INIS)

    Goldmann, L.H.; Frederickson, J.R.

    1983-01-01

    The objective of the Secure Automated Fabrication (SAF) Project is to develop remotely operated equipment for the processing and manufacturing of breeder reactor fuel pins. The SAF line will be installed in the Fuels and Materials Examination Facility (FMEF). The FMEF is presently under construction at the Department of Energy's (DOE) Hanford site near Richland, Washington, and is operated by the Westinghouse Hanford Company (WHC). The fabrication and support systems of the SAF line are designed for computer-controlled operation from a centralized control room. Remote and automated fuel fabriction operations will result in: reduced radiation exposure to workers; enhanced safeguards; improved product quality; near real-time accountability, and increased productivity. The present schedule calls for installation of SAF line equipment in the FMEF beginning in 1984, with qualifying runs starting in 1986 and production commencing in 1987. 5 figures

  9. Automated multiple failure FMEA

    International Nuclear Information System (INIS)

    Price, C.J.; Taylor, N.S.

    2002-01-01

    Failure mode and effects analysis (FMEA) is typically performed by a team of engineers working together. In general, they will only consider single point failures in a system. Consideration of all possible combinations of failures is impractical for all but the simplest example systems. Even if the task of producing the FMEA report for the full multiple failure scenario were automated, it would still be impractical for the engineers to read, understand and act on all of the results. This paper shows how approximate failure rates for components can be used to select the most likely combinations of failures for automated investigation using simulation. The important information can be automatically identified from the resulting report, making it practical for engineers to study and act on the results. The strategy described in the paper has been applied to a range of electrical subsystems, and the results have confirmed that the strategy described here works well for realistically complex systems

  10. Automated drawing generation system

    International Nuclear Information System (INIS)

    Yoshinaga, Toshiaki; Kawahata, Junichi; Yoshida, Naoto; Ono, Satoru

    1991-01-01

    Since automated CAD drawing generation systems still require human intervention, improvements were focussed on an interactive processing section (data input and correcting operation) which necessitates a vast amount of work. As a result, human intervention was eliminated, the original objective of a computerized system. This is the first step taken towards complete automation. The effects of development and commercialization of the system are as described below. (1) The interactive processing time required for generating drawings was improved. It was determined that introduction of the CAD system has reduced the time required for generating drawings. (2) The difference in skills between workers preparing drawings has been eliminated and the quality of drawings has been made uniform. (3) The extent of knowledge and experience demanded of workers has been reduced. (author)

  11. ATLAS Distributed Computing Automation

    CERN Document Server

    Schovancova, J; The ATLAS collaboration; Borrego, C; Campana, S; Di Girolamo, A; Elmsheuser, J; Hejbal, J; Kouba, T; Legger, F; Magradze, E; Medrano Llamas, R; Negri, G; Rinaldi, L; Sciacca, G; Serfon, C; Van Der Ster, D C

    2012-01-01

    The ATLAS Experiment benefits from computing resources distributed worldwide at more than 100 WLCG sites. The ATLAS Grid sites provide over 100k CPU job slots, over 100 PB of storage space on disk or tape. Monitoring of status of such a complex infrastructure is essential. The ATLAS Grid infrastructure is monitored 24/7 by two teams of shifters distributed world-wide, by the ATLAS Distributed Computing experts, and by site administrators. In this paper we summarize automation efforts performed within the ATLAS Distributed Computing team in order to reduce manpower costs and improve the reliability of the system. Different aspects of the automation process are described: from the ATLAS Grid site topology provided by the ATLAS Grid Information System, via automatic site testing by the HammerCloud, to automatic exclusion from production or analysis activities.

  12. Automated Analysis of Accountability

    DEFF Research Database (Denmark)

    Bruni, Alessandro; Giustolisi, Rosario; Schürmann, Carsten

    2017-01-01

    that the system can detect the misbehaving parties who caused that failure. Accountability is an intuitively stronger property than verifiability as the latter only rests on the possibility of detecting the failure of a goal. A plethora of accountability and verifiability definitions have been proposed...... in the literature. Those definitions are either very specific to the protocols in question, hence not applicable in other scenarios, or too general and widely applicable but requiring complicated and hard to follow manual proofs. In this paper, we advance formal definitions of verifiability and accountability...... that are amenable to automated verification. Our definitions are general enough to be applied to different classes of protocols and different automated security verification tools. Furthermore, we point out formally the relation between verifiability and accountability. We validate our definitions...

  13. Automation and Mankind

    Science.gov (United States)

    1960-08-07

    limited by the cap- abilities of the human organism in the matter of control of its processes. In our time, the speeds of technological processes are...in many cases limited by conditions of control. The speed of human reaction is limited and therefore, at pre- sent, only processes of a relatively...forwiard, It can e foreseer thast automIation will comp~letely free Mans -Pn work unler conlitions’ of high texpemratures pressures,, anid nollutA-: or

  14. Automated Cooperative Trajectories

    Science.gov (United States)

    Hanson, Curt; Pahle, Joseph; Brown, Nelson

    2015-01-01

    This presentation is an overview of the Automated Cooperative Trajectories project. An introduction to the phenomena of wake vortices is given, along with a summary of past research into the possibility of extracting energy from the wake by flying close parallel trajectories. Challenges and barriers to adoption of civilian automatic wake surfing technology are identified. A hardware-in-the-loop simulation is described that will support future research. Finally, a roadmap for future research and technology transition is proposed.

  15. Automating ASW fusion

    OpenAIRE

    Pabelico, James C.

    2011-01-01

    Approved for public release; distribution is unlimited. This thesis examines ASW eFusion, an anti-submarine warfare (ASW) tactical decision aid (TDA) that utilizes Kalman filtering to improve battlespace awareness by simplifying and automating the track management process involved in anti-submarine warfare (ASW) watchstanding operations. While this program can currently help the ASW commander manage uncertainty and make better tactical decisions, the program has several limitations. Comman...

  16. Autonomy, Automation, and Systems

    Science.gov (United States)

    Turner, Philip R.

    1987-02-01

    Aerospace industry interest in autonomy and automation, given fresh impetus by the national goal of establishing a Space Station, is becoming a major item of research and technology development. The promise of new technology arising from research in Artificial Intelligence (AI) has focused much attention on its potential in autonomy and automation. These technologies can improve performance in autonomous control functions that involve planning, scheduling, and fault diagnosis of complex systems. There are, however, many aspects of system and subsystem design in an autonomous system that impact AI applications, but do not directly involve AI technology. Development of a system control architecture, establishment of an operating system within the design, providing command and sensory data collection features appropriate to automated operation, and the use of design analysis tools to support system engineering are specific examples of major design issues. Aspects such as these must also receive attention and technology development support if we are to implement complex autonomous systems within the realistic limitations of mass, power, cost, and available flight-qualified technology that are all-important to a flight project.

  17. Longwall automation 2

    Energy Technology Data Exchange (ETDEWEB)

    David Hainsworth; David Reid; Con Caris; J.C. Ralston; C.O. Hargrave; Ron McPhee; I.N. Hutchinson; A. Strange; C. Wesner [CSIRO (Australia)

    2008-05-15

    This report covers a nominal two-year extension to the Major Longwall Automation Project (C10100). Production standard implementation of Longwall Automation Steering Committee (LASC) automation systems has been achieved at Beltana and Broadmeadow mines. The systems are now used on a 24/7 basis and have provided production benefits to the mines. The LASC Information System (LIS) has been updated and has been implemented successfully in the IT environment of major coal mining houses. This enables 3D visualisation of the longwall environment and equipment to be accessed on line. A simulator has been specified and a prototype system is now ready for implementation. The Shearer Position Measurement System (SPMS) has been upgraded to a modular commercial production standard hardware solution.A compact hardware solution for visual face monitoring has been developed, an approved enclosure for a thermal infrared camera has been produced and software for providing horizon control through faulted conditions has been delivered. The incorporation of the LASC Cut Model information into OEM horizon control algorithms has been bench and underground tested. A prototype system for shield convergence monitoring has been produced and studies to identify techniques for coal flow optimisation and void monitoring have been carried out. Liaison with equipment manufacturers has been maintained and technology delivery mechanisms for LASC hardware and software have been established.

  18. Automation in biological crystallization.

    Science.gov (United States)

    Stewart, Patrick Shaw; Mueller-Dieckmann, Jochen

    2014-06-01

    Crystallization remains the bottleneck in the crystallographic process leading from a gene to a three-dimensional model of the encoded protein or RNA. Automation of the individual steps of a crystallization experiment, from the preparation of crystallization cocktails for initial or optimization screens to the imaging of the experiments, has been the response to address this issue. Today, large high-throughput crystallization facilities, many of them open to the general user community, are capable of setting up thousands of crystallization trials per day. It is thus possible to test multiple constructs of each target for their ability to form crystals on a production-line basis. This has improved success rates and made crystallization much more convenient. High-throughput crystallization, however, cannot relieve users of the task of producing samples of high quality. Moreover, the time gained from eliminating manual preparations must now be invested in the careful evaluation of the increased number of experiments. The latter requires a sophisticated data and laboratory information-management system. A review of the current state of automation at the individual steps of crystallization with specific attention to the automation of optimization is given.

  19. A Fully Automated High-Throughput Zebrafish Behavioral Ototoxicity Assay.

    Science.gov (United States)

    Todd, Douglas W; Philip, Rohit C; Niihori, Maki; Ringle, Ryan A; Coyle, Kelsey R; Zehri, Sobia F; Zabala, Leanne; Mudery, Jordan A; Francis, Ross H; Rodriguez, Jeffrey J; Jacob, Abraham

    2017-08-01

    Zebrafish animal models lend themselves to behavioral assays that can facilitate rapid screening of ototoxic, otoprotective, and otoregenerative drugs. Structurally similar to human inner ear hair cells, the mechanosensory hair cells on their lateral line allow the zebrafish to sense water flow and orient head-to-current in a behavior called rheotaxis. This rheotaxis behavior deteriorates in a dose-dependent manner with increased exposure to the ototoxin cisplatin, thereby establishing itself as an excellent biomarker for anatomic damage to lateral line hair cells. Building on work by our group and others, we have built a new, fully automated high-throughput behavioral assay system that uses automated image analysis techniques to quantify rheotaxis behavior. This novel system consists of a custom-designed swimming apparatus and imaging system consisting of network-controlled Raspberry Pi microcomputers capturing infrared video. Automated analysis techniques detect individual zebrafish, compute their orientation, and quantify the rheotaxis behavior of a zebrafish test population, producing a powerful, high-throughput behavioral assay. Using our fully automated biological assay to test a standardized ototoxic dose of cisplatin against varying doses of compounds that protect or regenerate hair cells may facilitate rapid translation of candidate drugs into preclinical mammalian models of hearing loss.

  20. Can formalizing links among community health workers, accredited drug dispensing outlet dispensers, and health facility staff increase their collaboration to improve prompt access to maternal and child care? A qualitative study in Tanzania.

    Science.gov (United States)

    Dillip, Angel; Kimatta, Suleiman; Embrey, Martha; Chalker, John C; Valimba, Richard; Malliwah, Mariam; Meena, John; Lieber, Rachel; Johnson, Keith

    2017-06-19

    In Tanzania, progress toward achieving the 2015 Millennium Development Goals for maternal and newborn health was slow. An intervention brought together community health workers, health facility staff, and accredited drug dispensing outlet (ADDO) dispensers to improve maternal and newborn health through a mechanism of collaboration and referral. This study explored barriers, successes, and promising approaches to increasing timely access to care by linking the three levels of health care provision. The study was conducted in the Kibaha district, where we applied qualitative approaches with in-depth interviews and focus group discussions. In-depth interview participants included retail drug shop dispensers (36), community health workers (45), and health facility staff members (15). We conducted one focus group discussion with district officials and four with mothers of newborns and children under 5 years old. Relationships among the three levels of care improved after the linkage intervention, especially for ADDO dispensers and health facility staff who previously had no formal communication pathway. The study participants perceptions of success included improved knowledge of case management and relationships among the three levels of care, more timely access to care, increased numbers of patients/customers, more meetings between community health workers and health facility staff, and a decrease in child and maternal mortality. Reported challenges included stock-outs of medicines at the health facility, participating ADDO dispensers who left to work in other regions, documentation of referrals, and lack of treatment available at health facilities on the weekend. The primary issue that threatens the sustainability of the intervention is that local council health management team members, who are responsible for facilitating the linkage, had not made any supervision visits and were therefore unaware of how the program was running. The study highlights the benefits of

  1. Design, microfabrication, and characterization of a moulded PDMS/SU-8 inkjet dispenser for a Lab-on-a-Printer platform technology with disposable microfluidic chip.

    Science.gov (United States)

    Bsoul, Anas; Pan, Sheng; Cretu, Edmond; Stoeber, Boris; Walus, Konrad

    2016-08-16

    In this paper, we present a disposable inkjet dispenser platform technology and demonstrate the Lab-on-a-Printer concept, an extension of the ubiquitous Lab-on-a-Chip concept, whereby microfluidic modules are directly integrated into the printhead. The concept is demonstrated here through the integration of an inkjet dispenser and a microfluidic mixer enabling control over droplet composition from a single nozzle in real-time during printing. The inkjet dispenser is based on a modular design platform that enables the low-cost microfluidic component and the more expensive actuation unit to be easily separated, allowing for the optional disposal of the former and reuse of the latter. To limit satellite droplet formation, a hydrophobic-coated and tapered micronozzle was microfabricated and integrated with the fluidics to realize the dispenser. The microfabricated devices generated droplets with diameters ranging from 150-220 μm, depending mainly on the orifice diameter, with printing rates up to 8000 droplets per second. The inkjet dispenser is capable of dispensing materials with a viscosity up to ∼19 mPa s. As a demonstration of the inkjet dispenser function and application, we have printed type I collagen seeded with human liver carcinoma cells (cell line HepG2), to form patterned biological structures.

  2. Automated personal dosimetry monitoring system for NPP

    International Nuclear Information System (INIS)

    Chanyshev, E.; Chechyotkin, N.; Kondratev, A.; Plyshevskaya, D.

    2006-01-01

    Full text: Radiation safety of personnel at nuclear power plants (NPP) is a priority aim. Degree of radiation exposure of personnel is defined by many factors: NPP design, operation of equipment, organizational management of radiation hazardous works and, certainly, safety culture of every employee. Automated Personal Dosimetry Monitoring System (A.P.D.M.S.) is applied at all nuclear power plants nowadays in Russia to eliminate the possibility of occupational radiation exposure beyond regulated level under different modes of NPP operation. A.P.D.M.S. provides individual radiation dose registration. In the paper the efforts of Design Bureau 'Promengineering' in construction of software and hardware complex of A.P.D.M.S. (S.H.W. A.P.D.M.S.) for NPP with PWR are presented. The developed complex is intended to automatize activities of radiation safety department when caring out individual dosimetry control. The complex covers all main processes concerning individual monitoring of external and internal radiation exposure as well as dose recording, management, and planning. S.H.W. A.P.D.M.S. is a multi-purpose system which software was designed on the modular approach. This approach presumes modification and extension of software using new components (modules) without changes in other components. Such structure makes the system flexible and allows modifying it in case of implementation a new radiation safety requirements and extending the scope of dosimetry monitoring. That gives the possibility to include with time new kinds of dosimetry control for Russian NPP in compliance with IAEA recommendations, for instance, control of the equivalent dose rate to the skin and the equivalent dose rate to the lens of the eye S.H.W. A.P.D.M.S. provides dosimetry control as follows: Current monitoring of external radiation exposure: - Gamma radiation dose measurement using radio-photoluminescent personal dosimeters. - Neutron radiation dose measurement using thermoluminescent

  3. A new fully automated TLD badge reader

    International Nuclear Information System (INIS)

    Kannan, S.; Ratna, P.; Kulkarni, M.S.

    2003-01-01

    At present personnel monitoring in India is being carried out using a number of manual and semiautomatic TLD badge Readers and the BARC TL dosimeter badge designed during 1970. Of late the manual TLD badge readers are almost completely replaced by semiautomatic readers with a number of performance improvements like use of hot gas heating to reduce the readout time considerably. PC based design with storage of glow curve for every dosimeter, on-line dose computation and printout of dose reports, etc. However the semiautomatic system suffers from the lack of a machine readable ID code on the badge and the physical design of the dosimeter card not readily compatible for automation. This paper describes a fully automated TLD badge Reader developed in the RSS Division, using a new TLD badge with machine readable ID code. The new PC based reader has a built-in reader for reading the ID code, in the form of an array of holes, on the dosimeter card. The reader has a number of self-diagnostic features to ensure a high degree of reliability. (author)

  4. Dose rate constants for new dose quantities

    International Nuclear Information System (INIS)

    Tschurlovits, M.; Daverda, G.; Leitner, A.

    1992-01-01

    Conceptual changes and new quantities made is necessary to reassess dose rate quantities. Calculations of the dose rate constant were done for air kerma, ambient dose equivalent and directional dose equivalent. The number of radionuclides is more than 200. The threshold energy is selected as 20 keV for the dose equivalent constants. The dose rate constant for the photon equivalent dose as used mainly in German speaking countries as a temporary quantity is also included. (Author)

  5. The impact of ethnic density on dispensing of antipsychotic and antidepressant medication among immigrants in the Netherlands.

    Science.gov (United States)

    Termorshuizen, Fabian; Heerdink, Eibert R; Selten, Jean-Paul

    2018-06-12

    A higher own-group ethnic density in the area of residence is often associated with a lower risk for psychotic disorder. For common mental disorders the evidence is less convincing. This study explores whether these findings are mirrored in data on dispensing of antipsychotics and antidepressants. Health insurance data on dispensed medication among all adults living in the four largest Dutch cities were linked to demographic data from Statistics Netherlands. Dispensing of antipsychotics and antidepressants in 2013 was analyzed in relation to the proportion of the own ethnic group in the neighborhood. Higher own-group ethnic density was associated with lower dispensing of antipsychotics among the Moroccan-Dutch (N = 115,455), after adjusting for age, gender, and SES of the neighborhood (OR adj for the highest vs. the lowest density quintile = 0.72 [0.66-0.79]). However, this association vanished after adjustment for household composition (OR adj  = 0.93 [0.85-1.03]). Similar results were found for the Turkish-Dutch (N = 105,460) (OR adj  = 0.86 [0.76-0.96] and 1.05 [0.94-1.18]). For those of Surinamese (N = 147,123) and Antillean origin (N = 41,430), in contrast, the association between ethnic density and lower risk remained after each adjustment (P density was consistently found for those of Antillean origin (OR adj  = 0.62 [0.52-0.74]) only. These data on dispensing of psychomedication confirm the ethnic density hypothesis for psychosis alongside earlier equivocal findings for other mental disorders. The negative association between own-group ethnic density and dispensing of antipsychotics among the Moroccan- and Turkish-Dutch may be explained, at least in part, by a favourable household composition (i.e., living in a family) in high-density neighborhoods. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Automation, Performance and International Competition

    DEFF Research Database (Denmark)

    Kromann, Lene; Sørensen, Anders

    This paper presents new evidence on trade‐induced automation in manufacturing firms using unique data combining a retrospective survey that we have assembled with register data for 2005‐2010. In particular, we establish a causal effect where firms that have specialized in product types for which...... the Chinese exports to the world market has risen sharply invest more in automated capital compared to firms that have specialized in other product types. We also study the relationship between automation and firm performance and find that firms with high increases in scale and scope of automation have faster...... productivity growth than other firms. Moreover, automation improves the efficiency of all stages of the production process by reducing setup time, run time, and inspection time and increasing uptime and quantity produced per worker. The efficiency improvement varies by type of automation....

  7. Automation in organizations: Eternal conflict

    Science.gov (United States)

    Dieterly, D. L.

    1981-01-01

    Some ideas on and insights into the problems associated with automation in organizations are presented with emphasis on the concept of automation, its relationship to the individual, and its impact on system performance. An analogy is drawn, based on an American folk hero, to emphasize the extent of the problems encountered when dealing with automation within an organization. A model is proposed to focus attention on a set of appropriate dimensions. The function allocation process becomes a prominent aspect of the model. The current state of automation research is mentioned in relation to the ideas introduced. Proposed directions for an improved understanding of automation's effect on the individual's efficiency are discussed. The importance of understanding the individual's perception of the system in terms of the degree of automation is highlighted.

  8. The Quality of Selected Essential Medicines Sold in Accredited Drug Dispensing Outlets and Pharmacies in Tanzania.

    Directory of Open Access Journals (Sweden)

    Eliangiringa Kaale

    Full Text Available The purpose of this study was to investigate the quality of a select group of medicines sold in accredited drug dispensing outlets (ADDOs and pharmacies in different regions of Tanzania as part of an in-depth cross-sectional assessment of community access to medicines and community use of medicines.We collected 242 samples of amoxicillin trihydrate, artemether-lumefantrine (ALu, co-trimoxazole, ergometrine maleate, paracetamol, and quinine from selected ADDOs and pharmacies in Mbeya, Morogoro, Singida, and Tanga regions. The analysis included physical examination and testing with validated analytical techniques. Assays for eight of nine products were conducted using high-performance thin-layer chromatography (HPTLC. For ALu tablets, we used a two-tiered approach, where tier 1 was a semi-quantitative Global Pharma Health Fund-Minilab® method and tier 2 was high-performance liquid chromatography (HPLC as described in The International Pharmacopoeia's monograph for artemether-lumefantrine.The physical examination of samples revealed no defects in the solid and oral liquid dosage forms, but unusual discoloration in an injectable solution, ergometrine maleate. For ALu, the results showed that of 38 samples, 31 (81.6% passed tier 1 testing and 7 (18.4% gave inconclusive drug content results. The inconclusive ALu samples were submitted for tier 2 testing and all met the quality standards. The pass rate using the HPTLC and TLC/HPLC assays was 93.8%; the failures were the ergometrine maleate samples purchased from both ADDOs and pharmacies. The disintegration testing of the solid dosage forms was conducted in accordance with US Pharmacopeia monographs. Only two samples of paracetamol, 1.2% of the solid dosage forms, failed to comply to standards. The study revealed a high overall rate of 92.6% of samples that met the quality standards. Although the overall failure rate was 7.4%, it is important to note that this was largely limited to one product and

  9. Tiger Teams Technical Assistance: Reliable, Universal Open Architecture for Card Access to Dispense Alternative Fuels

    Energy Technology Data Exchange (ETDEWEB)

    2002-03-01

    Report discusses the dilemma of incorporating consistent, convenient, universal card access (or ''pay-at-the-pump'') systems into alternative fueling stations across the country. The state of California continues to be in the forefront of implementing alternative fuels for transportation applications. Aggressive efforts to deploy alternative fuel vehicles (AFVs) in California have highlighted the need to provide adequate fueling stations and develop appropriate, user-friendly means to purchase fuel at the pump. Since these fuels are not typically provided by petroleum companies at conventional fueling stations, and acceptance of cash is often not an option, a payment method must be developed that is consistent with the way individual AFV operators are accustomed to purchasing automotive fuels--with a credit card. At the same time, large fleets like the California Department of General Services must be able to use a single fuel card that offers comprehensive fleet management services. The Gas Technology Institute's Infrastructure Working Group (IWG) and its stakeholders have identified the lack of a common card reader system as a hurdle to wider deployment of AFVs in California and the United States. In conjunction with the U.S. Department of Energy's (DOE) National Clean Cities Program, the IWG has outlined a multi-phased strategy to systematically address the barriers to develop a more ''open'' architecture that's similar to the way gasoline and diesel are currently dispensed. Under the auspices of the IWG, survey results were gathered (circa 1999) from certain fuel providers, as a means to more carefully study card reader issues and their potential solutions. Pilot programs featuring card reader systems capable of accepting wider payment options have been attempted in several regions of the United States with mixed success. In early 2001, DOE joined the National Renewable Energy Laboratory (NREL), the

  10. The Quality of Selected Essential Medicines Sold in Accredited Drug Dispensing Outlets and Pharmacies in Tanzania.

    Science.gov (United States)

    Kaale, Eliangiringa; Manyanga, Vicky; Chambuso, Mhina; Liana, Jafary; Rutta, Edmund; Embrey, Martha; Layloff, Thomas; Johnson, Keith

    2016-01-01

    The purpose of this study was to investigate the quality of a select group of medicines sold in accredited drug dispensing outlets (ADDOs) and pharmacies in different regions of Tanzania as part of an in-depth cross-sectional assessment of community access to medicines and community use of medicines. We collected 242 samples of amoxicillin trihydrate, artemether-lumefantrine (ALu), co-trimoxazole, ergometrine maleate, paracetamol, and quinine from selected ADDOs and pharmacies in Mbeya, Morogoro, Singida, and Tanga regions. The analysis included physical examination and testing with validated analytical techniques. Assays for eight of nine products were conducted using high-performance thin-layer chromatography (HPTLC). For ALu tablets, we used a two-tiered approach, where tier 1 was a semi-quantitative Global Pharma Health Fund-Minilab® method and tier 2 was high-performance liquid chromatography (HPLC) as described in The International Pharmacopoeia's monograph for artemether-lumefantrine. The physical examination of samples revealed no defects in the solid and oral liquid dosage forms, but unusual discoloration in an injectable solution, ergometrine maleate. For ALu, the results showed that of 38 samples, 31 (81.6%) passed tier 1 testing and 7 (18.4%) gave inconclusive drug content results. The inconclusive ALu samples were submitted for tier 2 testing and all met the quality standards. The pass rate using the HPTLC and TLC/HPLC assays was 93.8%; the failures were the ergometrine maleate samples purchased from both ADDOs and pharmacies. The disintegration testing of the solid dosage forms was conducted in accordance with US Pharmacopeia monographs. Only two samples of paracetamol, 1.2% of the solid dosage forms, failed to comply to standards. The study revealed a high overall rate of 92.6% of samples that met the quality standards. Although the overall failure rate was 7.4%, it is important to note that this was largely limited to one product and likely due to

  11. Automation System Products and Research

    OpenAIRE

    Rintala, Mikko; Sormunen, Jussi; Kuisma, Petri; Rahkala, Matti

    2014-01-01

    Automation systems are used in most buildings nowadays. In the past they were mainly used in industry to control and monitor critical systems. During the past few decades the automation systems have become more common and are used today from big industrial solutions to homes of private customers. With the growing need for ecologic and cost-efficient management systems, home and building automation systems are becoming a standard way of controlling lighting, ventilation, heating etc. Auto...

  12. Guidelines for Automation Project Execution

    OpenAIRE

    Takkinen, Heidi

    2011-01-01

    The purpose of this Master’s thesis was to create instructions for executing an automation project. Sarlin Oy Ab needed directions on how to execute an automation project. Sarlin is starting up a new business area offering total project solutions for customers. Sarlin focuses on small and minor automation projects on domestic markets. The thesis represents issues related to project execution starting from the theory of the project to its kick-off and termination. Site work is one importan...

  13. 78 FR 53466 - Modification of Two National Customs Automation Program (NCAP) Tests Concerning Automated...

    Science.gov (United States)

    2013-08-29

    ... Customs Automation Program (NCAP) Tests Concerning Automated Commercial Environment (ACE) Document Image... National Customs Automation Program (NCAP) tests concerning document imaging, known as the Document Image... the National Customs Automation Program (NCAP) tests concerning document imaging, known as the...

  14. World-wide distribution automation systems

    International Nuclear Information System (INIS)

    Devaney, T.M.

    1994-01-01

    A worldwide power distribution automation system is outlined. Distribution automation is defined and the status of utility automation is discussed. Other topics discussed include a distribution management system, substation feeder, and customer functions, potential benefits, automation costs, planning and engineering considerations, automation trends, databases, system operation, computer modeling of system, and distribution management systems

  15. Contaminant analysis automation, an overview

    International Nuclear Information System (INIS)

    Hollen, R.; Ramos, O. Jr.

    1996-01-01

    To meet the environmental restoration and waste minimization goals of government and industry, several government laboratories, universities, and private companies have formed the Contaminant Analysis Automation (CAA) team. The goal of this consortium is to design and fabricate robotics systems that standardize and automate the hardware and software of the most common environmental chemical methods. In essence, the CAA team takes conventional, regulatory- approved (EPA Methods) chemical analysis processes and automates them. The automation consists of standard laboratory modules (SLMs) that perform the work in a much more efficient, accurate, and cost- effective manner

  16. Automating CPM-GOMS

    Science.gov (United States)

    John, Bonnie; Vera, Alonso; Matessa, Michael; Freed, Michael; Remington, Roger

    2002-01-01

    CPM-GOMS is a modeling method that combines the task decomposition of a GOMS analysis with a model of human resource usage at the level of cognitive, perceptual, and motor operations. CPM-GOMS models have made accurate predictions about skilled user behavior in routine tasks, but developing such models is tedious and error-prone. We describe a process for automatically generating CPM-GOMS models from a hierarchical task decomposition expressed in a cognitive modeling tool called Apex. Resource scheduling in Apex automates the difficult task of interleaving the cognitive, perceptual, and motor resources underlying common task operators (e.g. mouse move-and-click). Apex's UI automatically generates PERT charts, which allow modelers to visualize a model's complex parallel behavior. Because interleaving and visualization is now automated, it is feasible to construct arbitrarily long sequences of behavior. To demonstrate the process, we present a model of automated teller interactions in Apex and discuss implications for user modeling. available to model human users, the Goals, Operators, Methods, and Selection (GOMS) method [6, 21] has been the most widely used, providing accurate, often zero-parameter, predictions of the routine performance of skilled users in a wide range of procedural tasks [6, 13, 15, 27, 28]. GOMS is meant to model routine behavior. The user is assumed to have methods that apply sequences of operators and to achieve a goal. Selection rules are applied when there is more than one method to achieve a goal. Many routine tasks lend themselves well to such decomposition. Decomposition produces a representation of the task as a set of nested goal states that include an initial state and a final state. The iterative decomposition into goals and nested subgoals can terminate in primitives of any desired granularity, the choice of level of detail dependent on the predictions required. Although GOMS has proven useful in HCI, tools to support the

  17. Automating dipole subtraction

    International Nuclear Information System (INIS)

    Hasegawa, K.; Moch, S.; Uwer, P.

    2008-07-01

    We report on automating the Catani-Seymour dipole subtraction which is a general procedure to treat infrared divergences in real emission processes at next-to-leading order in QCD. The automatization rests on three essential steps: the creation of the dipole terms, the calculation of the color linked squared Born matrix elements, and the evaluation of different helicity amplitudes. The routines have been tested for a number of complex processes, such as the real emission process gg→t anti tggg. (orig.)

  18. Automating dipole subtraction

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, K.; Moch, S. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Uwer, P. [Karlsruhe Univ. (T.H.) (Germany). Inst. fuer Theoretische Teilchenphysik

    2008-07-15

    We report on automating the Catani-Seymour dipole subtraction which is a general procedure to treat infrared divergences in real emission processes at next-to-leading order in QCD. The automatization rests on three essential steps: the creation of the dipole terms, the calculation of the color linked squared Born matrix elements, and the evaluation of different helicity amplitudes. The routines have been tested for a number of complex processes, such as the real emission process gg{yields}t anti tggg. (orig.)

  19. Fossil power plant automation

    International Nuclear Information System (INIS)

    Divakaruni, S.M.; Touchton, G.

    1991-01-01

    This paper elaborates on issues facing the utilities industry and seeks to address how new computer-based control and automation technologies resulting from recent microprocessor evolution, can improve fossil plant operations and maintenance. This in turn can assist utilities to emerge stronger from the challenges ahead. Many presentations at the first ISA/EPRI co-sponsored conference are targeted towards improving the use of computer and control systems in the fossil and nuclear power plants and we believe this to be the right forum to share our ideas

  20. Extension of the commercial agreement on water dispensers: appendices 1-4; Erweiterung der Branchenvereinbarung Wasserdispenser. Anhaenge 1-4

    Energy Technology Data Exchange (ETDEWEB)

    Grieder, T.; Huser, A.

    2006-07-01

    These appendices to a final report for the Swiss Federal Office of Energy (SFOE) present the results of work done within the framework of a voluntary agreement between the Federal Office of Energy and the four most important suppliers of bottled water dispensers in Switzerland. The first appendix lists water dispensers with water-mains connections and quotes figures on the number of units and their energy use. Two prognoses are presented for the year 2015, one with and one without any action being taken. The second appendix presents the German Gas and Water association's suggestion for standards, while the third appendix presents the hygiene regulations of the Swiss Department of Home Affairs. The fourth appendix presents the answer sent by the U.S.A's Environmental Protection Agency to an e-mail on the subject.