WorldWideScience

Sample records for au-ag electrodes influence

  1. Electrochemical Glucose Oxidation Using Glassy Carbon Electrodes Modified with Au-Ag Nanoparticles: Influence of Ag Content

    Directory of Open Access Journals (Sweden)

    Nancy Gabriela García-Morales

    2015-01-01

    Full Text Available This paper describes the application of glassy carbon modified electrodes bearing Aux-Agy nanoparticles to catalyze the electrochemical oxidation of glucose. In particular, the paper shows the influence of the Ag content on this oxidation process. A simple method was applied to prepare the nanoparticles, which were characterized by transmission electron microscopy, Ultraviolet-Visible spectroscopy, X-ray diffraction spectroscopy, and cyclic voltammetry. These nanoparticles were used to modify glassy carbon electrodes. The effectiveness of these electrodes for electrochemical glucose oxidation was evaluated. The modified glassy carbon electrodes are highly sensitive to glucose oxidation in alkaline media, which could be attributed to the presence of Aux-Agy nanoparticles on the electrode surface. The voltammetric results suggest that the glucose oxidation speed is controlled by the glucose diffusion to the electrode surface. These results also show that the catalytic activity of the electrodes depends on the Ag content of the nanoparticles. Best results were obtained for the Au80-Ag20 nanoparticles modified electrode. This electrode could be used for Gluconic acid (GA production.

  2. Direct electrochemical oxidation of S-captopril using gold electrodes modified with graphene-AuAg nanocomposites

    Science.gov (United States)

    Pogacean, Florina; Biris, Alexandru R; Coros, Maria; Lazar, Mihaela Diana; Watanabe, Fumiya; Kannarpady, Ganesh K; Al Said, Said A Farha; Biris, Alexandru S; Pruneanu, Stela

    2014-01-01

    In this paper, we present a novel approach for the electrochemical detection of S-captopril based on graphene AuAg nanostructures used to modify an Au electrode. Multi-layer graphene (Gr) sheets decorated with embedded bimetallic AuAg nanoparticles were successfully synthesized catalytically with methane as the carbon source. The two catalytic systems contained 1.0 wt% Ag and 1.0 wt% Au, while the second had a larger concentration of metals (1.5 wt% Ag and 1.5 wt% Au) and was used for the synthesis of the Gr-AuAg-1 and Gr-AuAg-1.5 multicomponent samples. High-resolution transmission electron microscopy analysis indicated the presence of graphene flakes that had regular shapes (square or rectangular) and dimensions in the tens to hundreds of nanometers. We found that the size of the embedded AuAg nanoparticles varied between 5 and 100 nm, with the majority being smaller than 20 nm. Advanced scanning transmission electron microscopy studies indicated a bimetallic characteristic of the metallic clusters. The resulting Gr-AuAg-1 and Gr-AuAg-1.5 samples were used to modify the surface of commonly used Au substrates and subsequently employed for the direct electrochemical oxidation of S-captopril. By comparing the differential pulse voltammograms recorded with the two modified electrodes at various concentrations of captopril, the peak current was determined to be well-defined, even at relatively low concentration (10−5 M), for the Au/Gr-AuAg-1.5 electrode. In contrast, the signals recorded with the Au/Gr-AuAg-1 electrode were poorly defined within a 5×10−6 to 5×10−3 M concentration range, and many of them overlapped with the background. Such composite materials could find significant applications in nanotechnology, sensing, or nanomedicine. PMID:24596464

  3. @AuAg nanostructures

    Science.gov (United States)

    Singh, Rina; Soni, R. K.

    2014-09-01

    Bimetallic and trimetallic nanoparticles have attracted significant attention in recent times due to their enhanced electrochemical and catalytic properties compared to monometallic nanoparticles. The numerical calculations using Mie theory has been carried out for three-layered metal nanoshell dielectric-metal-metal (DMM) system consisting of a particle with a dielectric core (Al@Al2O3), a middle metal Ag (Au) layer and an outer metal Au (Ag) shell. The results have been interpreted using plasmon hybridization theory. We have also prepared Al@Al2O3@Ag@Au and Al@Al2O3@AgAu triple-layered core-shell or alloy nanostructure by two-step laser ablation method and compared with calculated results. The synthesis involves temporal separations of Al, Ag, and Au deposition for step-by-step formation of triple-layered core-shell structure. To form Al@Ag nanoparticles, we ablated silver for 40 min in aluminium nanoparticle colloidal solution. As aluminium oxidizes easily in water to form alumina, the resulting structure is core-shell Al@Al2O3. The Al@Al2O3 particle acts as a seed for the incoming energetic silver particles for multilayered Al@Al2O3@Ag nanoparticles is formed. The silver target was then replaced by gold target and ablation was carried out for different ablation time using different laser energy for generation of Al@Al2O3@Ag@Au core-shell or Al@Al2O3@AgAu alloy. The formation of core-shell and alloy nanostructure was confirmed by UV-visible spectroscopy. The absorption spectra show shift in plasmon resonance peak of silver to gold in the range 400-520 nm with increasing ablation time suggesting formation of Ag-Au alloy in the presence of alumina particles in the solution.

  4. Core-shell Au/Ag nanoparticles embedded in silicate sol-gel ...

    Indian Academy of Sciences (India)

    Core-shell Au/Ag nanoparticles embedded in silicate sol-gel network for sensor application towards hydrogen peroxide ... The present study highlights the influence of molar composition of Ag nanoparticles in the Au/Ag bimetallic composition towards the electrocatalytic reduction and sensing of hydrogen peroxide in ...

  5. Influence of the noble metals (Pd, Au, Ag) in the thermoluminescent signal induced by radiation in the ZrO2

    International Nuclear Information System (INIS)

    Villa S, G.

    2006-01-01

    When increasing the use of the ionizing and non ionizing radiations (for example, gamma and ultraviolet radiation) in different areas of the science and technology, there is necessary to apply more accurate safety measures and to avoid over-exposures that could put in risk the life of workers that manipulate radiation sources, patient that are exposed to this under some medical treatment, as well as materials that undergo intentionally to radiation. Also, the UV radiation that arrives to the earth can cause some damages, to the one to weaken the protector layer of ozone the UV radiation increases that arrives to the earth surface being able to affect the alive beings and the materials. By this so much the development of new materials able to take a census of in a more accurate way, fields of gamma and UV radiation is becoming necessary. In this sense, this work presents the obtained results when quantifying radiation fields, through the analysis in the thermoluminescent behavior (TL) induced by the gamma and UV radiation in the zirconium dioxide synthesized by the sol gel method and doped with nanoparticles of Pd, Au and Ag. It is necessary to mention that in reported works in this respect its mention that the zircon has good thermoluminescent sensitivity induced by these radiation types, however it has shown high thermoluminescent instability that is translated in an important lost of the information after the irradiation. For that through the incorporation of the metallic nanoparticles it was intended to stabilize the TL behavior of zircon. The results showed that the doped zircon has a high sensitivity to the gamma and UV radiation. These also show that the ionizing and non ionizing radiation induce a thermoluminescent curve consisting of two TL peaks with maxima located around 65 C and 145 C and that the intensity is increased with the dose, following a lineal behavior in certain interval of dose exposure that is influenced by the presence of the nanoparticles

  6. Biosynthesis of Au, Ag and Au-Ag nanoparticles using edible mushroom extract

    Science.gov (United States)

    Philip, Daizy

    2009-07-01

    Integration of green chemistry principles to nanotechnology is one of the key issues in nanoscience research. There is growing need to develop environmentally benign metal nanoparticle synthesis process that do not use toxic chemicals in the synthesis protocols to avoid adverse effects in medical applications. Here, it is a report on extracellular synthesis method for the preparation of Au, Ag and Au-Ag nanoparticles in water, using the extract of Volvariella volvacea, a naturally occurring edible mushroom, as reducing and protecting agents. Gold nanoparticles of different sizes (20-150 nm) and shapes from triangular nanoprisms to nearly spherical and hexagonal are obtained by this novel method. The size and shape of gold nanoparticles are also found to depend on temperature of the extract. The silver nanoparticles are spherical with size ˜15 nm. There is increased productivity of nanoparticles as shown by sharp and intense surface plasmon resonance bands for the nanoparticles prepared using an excess of the extract. The Au-Ag nanoparticles prepared by co-reduction has only one plasmon band due to alloying of the constituents. All the synthesized nanoparticles are found to be photoluminescent and are highly crystalline as shown by SAED and XRD patterns with fcc phase oriented along the (1 1 1) plane. FTIR measurements were carried out to identify the possible biomolecules responsible for capping and efficient stabilization of the nanoparticles. It is found that Au nanoparticles are bound to proteins through free amino groups and silver nanoparticles through the carboxylate group of the amino acid residues. The position and intensity of the emission band is found to depend on composition of the nanoparticles indicating the possible use in therapeutic applications.

  7. Direct Cross-Linking of Au/Ag Alloy Nanoparticles into Monolithic Aerogels for Application in Surface-Enhanced Raman Scattering.

    Science.gov (United States)

    Gao, Xiaonan; Esteves, Richard J Alan; Nahar, Lamia; Nowaczyk, Jordan; Arachchige, Indika U

    2016-05-25

    The direct cross-linking of Au/Ag alloy nanoparticles (NPs) into high surface area, mesoporous Au/Ag aerogels via chemical oxidation of the surface ligands is reported. The precursor alloy NPs with composition-tunable morphologies were produced by galvanic replacement of the preformed Ag hollow NPs. The effect of Au:Ag molar ratio on the NP morphology and surface plasmon resonance has been thoroughly investigated and resulted in smaller Au/Ag alloy NPs (4-8 nm), larger Au/Ag alloy hollow NPs (40-45 nm), and Au/Ag alloy hollow particles decorated with smaller Au NPs (2-5 nm). The oxidative removal of surfactant ligands, followed by supercritical drying, is utilized to construct large (centimeter to millimeter) self-supported Au/Ag alloy aerogels. The resultant assemblies exhibit high surface areas (67-73 m(2)/g), extremely low densities (0.051-0.055 g/cm(3)), and interconnected mesoporous (2-50 nm) networks, making them of great interest for a number of new technologies. The influence of mesoporous gel morphology on surface-enhanced Raman scattering (SERS) has been studied using Rhodamine 101 (Rd 101) as the probe molecule. The alloy aerogels exhibit SERS signal intensities that are 10-42 times higher than those achieved from the precursor Au/Ag alloy NPs. The Au/Ag alloy aerogel III exhibits SERS sensing capability down to 1 nM level. The increased signal intensities attained for alloy aerogels are attributed to highly porous gel morphology and enhanced surface roughness that can potentially generate a large number of plasmonic hot spots, creating efficient SERS substrates for future applications.

  8. Influence of the noble metals (Pd, Au, Ag) in the thermoluminescent signal induced by radiation in the ZrO{sub 2}; Influencia de los metales nobles (Pd, Au, Ag) en la senal termoluminiscente inducida por la radiacion en la ZrO{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Villa S, G

    2006-07-01

    When increasing the use of the ionizing and non ionizing radiations (for example, gamma and ultraviolet radiation) in different areas of the science and technology, there is necessary to apply more accurate safety measures and to avoid over-exposures that could put in risk the life of workers that manipulate radiation sources, patient that are exposed to this under some medical treatment, as well as materials that undergo intentionally to radiation. Also, the UV radiation that arrives to the earth can cause some damages, to the one to weaken the protector layer of ozone the UV radiation increases that arrives to the earth surface being able to affect the alive beings and the materials. By this so much the development of new materials able to take a census of in a more accurate way, fields of gamma and UV radiation is becoming necessary. In this sense, this work presents the obtained results when quantifying radiation fields, through the analysis in the thermoluminescent behavior (TL) induced by the gamma and UV radiation in the zirconium dioxide synthesized by the sol gel method and doped with nanoparticles of Pd, Au and Ag. It is necessary to mention that in reported works in this respect its mention that the zircon has good thermoluminescent sensitivity induced by these radiation types, however it has shown high thermoluminescent instability that is translated in an important lost of the information after the irradiation. For that through the incorporation of the metallic nanoparticles it was intended to stabilize the TL behavior of zircon. The results showed that the doped zircon has a high sensitivity to the gamma and UV radiation. These also show that the ionizing and non ionizing radiation induce a thermoluminescent curve consisting of two TL peaks with maxima located around 65 C and 145 C and that the intensity is increased with the dose, following a lineal behavior in certain interval of dose exposure that is influenced by the presence of the nanoparticles

  9. Phytosynthesis of Au, Ag and Au-Ag bimetallic nanoparticles using aqueous extract and dried leaf of Anacardium occidentale.

    Science.gov (United States)

    Sheny, D S; Mathew, Joseph; Philip, Daizy

    2011-06-01

    Present study reports a green chemistry approach for the biosynthesis of Au, Ag, Au-Ag alloy and Au core-Ag shell nanoparticles using the aqueous extract and dried powder of Anacardium occidentale leaf. The effects of quantity of extract/powder, temperature and pH on the formation of nanoparticles are studied. The nanoparticles are characterized using UV-vis and FTIR spectroscopies, XRD, HRTEM and SAED analyses. XRD studies show that the particles are crystalline in the cubic phase. The formation of Au core-Ag shell nanoparticles is evidenced by the dark core and light shell images in TEM and is supported by the appearance of two SPR bands in the UV-vis spectrum. FTIR spectra of the leaf powder before and after the bioreduction of nanoparticles are used to identify possible functional groups responsible for the reduction and capping of nanoparticles. Water soluble biomolecules like polyols and proteins are expected to bring about the bio-reduction. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. A facile and green strategy for the synthesis of Au, Ag and Au-Ag alloy nanoparticles using aerial parts of R. hypocrateriformis extract and their biological evaluation.

    Science.gov (United States)

    Godipurge, S S; Yallappa, S; Biradar, Naveen J; Biradar, J S; Dhananjaya, B L; Hegde, Gajanan; Jagadish, K; Hegde, Gurumurthy

    2016-12-01

    A facile and green strategy is reported here to synthesize gold (Au), silver (Ag) and gold-silver (Au-Ag) alloy nanoparticles (NPs) through bio-reduction reactions of aqueous corresponding metal precursors mediated by extracts of aerial parts of R. hypocrateriformis, which act as both reducing and stabilizing agents, under microwave irradiation. UV-vis spectrophotometer, XRD, FT-IR, FESEM/TEM, TGA and EDAX analysis were used to characterize the obtained NPs. The formation of NPs is evident from their surface plasmon resonance peak observed at λ max =∼550, 450 and 500nm for Au, Ag and Au-Ag alloy NPs respectively. XRD pattern revealed that fcc structure, while FT-IR spectra signify the presence of phytochemicals adsorbed on NPs. Such a biofunctionalized NPs were characterized by their weight loss, 30% due to thermal degradation of plant phytochemicals observed in TG analysis. The spherical shape of Au, Ag and Au-Ag alloy NPs (∼10-50nm) is observed by FE-SEM/TEM images. EDAX analysis confirms the expected elemental composition. Moreover, these NPs showed enhanced antimicrobial, antioxidant, and anticancer activities, though it is more pronounced for Au-Ag alloy NPs, which is due to the combining effect of phytochemicals, Au and Ag metals. Thus, the biosynthesized NPs could be applied as effective growth inhibitors for various biomedical applications. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Synthesis, characterization and SERS activity of Au-Ag nanorods

    Science.gov (United States)

    Philip, Daizy; Gopchandran, K. G.; Unni, C.; Nissamudeen, K. M.

    2008-09-01

    The formation mechanism and morphology of Au-Ag bimetallic colloidal nanoparticles depend on the composition. Ag coated Au colloidal nanoparticles have been prepared by deposition of Ag through chemical reduction on performed Au colloid. The composition of the Au 100- x-Ag x particles was varied from x = 0 to 50. The obtained colloids were characterized by UV-vis spectroscopy and transmission electron microscopy (TEM). The Au 80-Ag 20 colloid consists of alloy nanorods with dimension of 25 nm × 100 nm. The activity of these nanorods in surface enhanced Raman spectroscopy (SERS) was checked by using sodium salicylate as an adsorbate probe. Intense SERS bands are observed indicating its usefulness as a SERS substrate in near infrared (NIR) laser excitation.

  12. Leaching of Au, Ag, and Pd from waste printed circuit boards of mobile phone by iodide lixiviant after supercritical water pre-treatment

    International Nuclear Information System (INIS)

    Xiu, Fu-Rong; Qi, Yingying; Zhang, Fu-Shen

    2015-01-01

    Highlights: • We report a novel process for recovering Au, Ag, and Pd from waste PCBs. • The effect of SCWO on the leaching of Au, Ag, and Pd in waste PCBs was studied. • SCWO was highly efficient for enhancing the leaching of Au, Ag, and Pd. • The optimum leaching parameters for Au, Ag, and Pd in iodine–iodide were studied. - Abstract: Precious metals are the most attractive resources in waste printed circuit boards (PCBs) of mobile phones. In this work, an alternative process for recovering Au, Ag, and Pd from waste PCBs of mobile phones by supercritical water oxidation (SCWO) pre-treatment combined with iodine–iodide leaching process was developed. In the process, the waste PCBs of mobile phones were pre-treated in supercritical water, then a diluted hydrochloric acid leaching (HL) process was used to recovery the Cu, whose leaching efficiency was approximately 100%, finally the resulting residue was subjected to the iodine–iodide leaching process for recovering the Au, Ag, and Pd. Experimental results indicated that SCWO pre-treatment temperature, time, and pressure had significant influence on the Au, Ag, and Pd leaching from (SCWO + HL)-treated waste PCBs. The optimal SCWO pre-treatment conditions were 420 °C and 60 min for Au and Pd, and 410 °C and 30 min for Ag. The optimum dissolution parameters for Au, Pd, and Ag in (SCWO + HL)-treated PCBs with iodine–iodide system were leaching time of 120 min (90 min for Ag), iodine/iodide mole ratio of 1:5 (1:6 for Ag), solid-to-liquid ratio (S/L) of 1:10 g/mL (1:8 g/mL for Ag), and pH of 9, respectively. It is believed that the process developed in this study is environment friendly for the recovery of Au, Ag, and Pd from waste PCBs of mobile phones by SCWO pre-treatment combined with iodine–iodide leaching process

  13. Leaching of Au, Ag, and Pd from waste printed circuit boards of mobile phone by iodide lixiviant after supercritical water pre-treatment

    Energy Technology Data Exchange (ETDEWEB)

    Xiu, Fu-Rong, E-mail: xiu_chem@hotmail.com [College of Ecological Environment and Urban Construction, Fujian University of Technology, Fuzhou 350108 (China); Qi, Yingying [College of Ecological Environment and Urban Construction, Fujian University of Technology, Fuzhou 350108 (China); Zhang, Fu-Shen [Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085 (China)

    2015-07-15

    Highlights: • We report a novel process for recovering Au, Ag, and Pd from waste PCBs. • The effect of SCWO on the leaching of Au, Ag, and Pd in waste PCBs was studied. • SCWO was highly efficient for enhancing the leaching of Au, Ag, and Pd. • The optimum leaching parameters for Au, Ag, and Pd in iodine–iodide were studied. - Abstract: Precious metals are the most attractive resources in waste printed circuit boards (PCBs) of mobile phones. In this work, an alternative process for recovering Au, Ag, and Pd from waste PCBs of mobile phones by supercritical water oxidation (SCWO) pre-treatment combined with iodine–iodide leaching process was developed. In the process, the waste PCBs of mobile phones were pre-treated in supercritical water, then a diluted hydrochloric acid leaching (HL) process was used to recovery the Cu, whose leaching efficiency was approximately 100%, finally the resulting residue was subjected to the iodine–iodide leaching process for recovering the Au, Ag, and Pd. Experimental results indicated that SCWO pre-treatment temperature, time, and pressure had significant influence on the Au, Ag, and Pd leaching from (SCWO + HL)-treated waste PCBs. The optimal SCWO pre-treatment conditions were 420 °C and 60 min for Au and Pd, and 410 °C and 30 min for Ag. The optimum dissolution parameters for Au, Pd, and Ag in (SCWO + HL)-treated PCBs with iodine–iodide system were leaching time of 120 min (90 min for Ag), iodine/iodide mole ratio of 1:5 (1:6 for Ag), solid-to-liquid ratio (S/L) of 1:10 g/mL (1:8 g/mL for Ag), and pH of 9, respectively. It is believed that the process developed in this study is environment friendly for the recovery of Au, Ag, and Pd from waste PCBs of mobile phones by SCWO pre-treatment combined with iodine–iodide leaching process.

  14. Hollow Au-Ag Nanoparticles Labeled Immunochromatography Strip for Highly Sensitive Detection of Clenbuterol

    Science.gov (United States)

    Wang, Jingyun; Zhang, Lei; Huang, Youju; Dandapat, Anirban; Dai, Liwei; Zhang, Ganggang; Lu, Xuefei; Zhang, Jiawei; Lai, Weihua; Chen, Tao

    2017-01-01

    The probe materials play a significant role in improving the detection efficiency and sensitivity of lateral-flow immunochromatographic test strip (ICTS). Unlike conventional ICTS assay usually uses single-component, solid gold nanoparticles as labeled probes, in our present study, a bimetallic, hollow Au-Ag nanoparticles (NPs) labeled ICTS was successfully developed for the detection of clenbuterol (CLE). The hollow Au-Ag NPs with different Au/Ag mole ratio and tunable size were synthesized by varying the volume ratio of [HAuCl4]:[Ag NPs] via the galvanic replacement reaction. The surface of hollow Ag-Au NPs was functionalized with 11-mercaptoundecanoic acid (MUA) for further covalently bonded with anti-CLE monoclonal antibody. Overall size of the Au-Ag NPs, size of the holes within individual NPs and also Au/Ag mole ratio have been systematically optimized to amplify both the visual inspection signals and the quantitative data. The sensitivity of optimized hollow Au-Ag NPs probes has been achieved even as low as 2 ppb in a short time (within 15 min), which is superior over the detection performance of conventional test strip using Au NPs. The optimized hollow Au-Ag NPs labeled test strip can be used as an ideal candidate for the rapid screening of CLE in food samples.

  15. Growth of Au@Ag core-shell pentatwinned nanorods: tuning the end facets.

    Science.gov (United States)

    Zhang, Weiqing; Goh, Hao Ying Johnny; Firdoz, Shaik; Lu, Xianmao

    2013-09-16

    Au@Ag core-shell nanorods with tunable end facets are obtained by coating Au bipyramids (BPs) with Ag. The resultant nanorods exhibit a pentatwinned crystal structure with tips terminated with either {110} or {111} facets. The control over the end facets is achieved by varying the capping agents and tuning the reduction rate of Ag. Specifically, when Ag is reduced slowly, Au@Ag nanorods with flat {110} end facets are formed with cetyltrimethylammonium bromide (CTAB) as the capping agent. If CTAB is replaced with cetyltrimethylammonium chloride (CTAC), Au@Ag nanorods with tips terminated with {111} facets are obtained. However, at a high Ag reduction rate, dumbbell-shaped Au@Ag nanorods are formed, with either CTAB or CTAC as the capping agent. The morphological evolution of the nanorods in each case is closely followed and a growth mechanism is proposed. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Controlled Synthesis of Au@AgAu Yolk-Shell Cuboctahedra with Well-Defined Facets.

    Science.gov (United States)

    Londono-Calderon, Alejandra; Bahena, Daniel; Yacaman, Miguel J

    2016-08-02

    The synthesis of Au@AgAu yolk-shell cuboctahedra nanoparticles formed by galvanic replacement in a seed-mediated method is described. Initially, single-crystal Au seeds are used for the formation of Au@Ag core-shell nanocubes, which serve as the template material for the deposition of an external Au layer. The well-controlled synthesis yields the formation of cuboctahedra nanoparticles with smooth inner and outer Au/Ag surfaces. The deposition/oxidation process is described to understand the formation of cuboctahedra and octahedra nanoparticles. The Au core maintains the initial morphology of the seed and remains static at the center of the yolk-shell because of residual Ag. Structural analysis of the shell indicates intrinsic stacking faults (SFs) near the surface. Energy dispersive X-ray spectroscopy (EDS) and X-ray photoelectron spectroscopy (XPS) compositional analysis show an Au-Ag nonordered alloy forming the shell. The three-dimensional structure of the nanoparticles presented open facets on the [111] as observed by electron tomography SIRT reconstruction over a stack of high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM) images. The geometrical model was validated by analyzing the direction of streaks in coherent nanobeam diffraction (NBD). The catalytic activity was evaluated using a model reaction based on the reduction of 4-nitrophenol (4-NTP) by NaBH4 in the presence of Au@AgAu yolk-shell nanoparticles.

  17. Phytosynthesis of stable Au, Ag and Au-Ag alloy nanoparticles using J. Sambac leaves extract, and their enhanced antimicrobial activity in presence of organic antimicrobials

    Science.gov (United States)

    Yallappa, S.; Manjanna, J.; Dhananjaya, B. L.

    2015-02-01

    A green chemistry approach for the synthesis of Au, Ag and Au-Ag alloy nanoparticles (NPs) using the corresponding metal precursors and Jasminum sambac leaves extract as both reducing and capping media, under microwave irradiation, is reported. During the formation, as expected, the reaction mixture shows marginal decrease in pH and an increase in solution potential. The formation of NPs is evident from their surface plasmon resonance (SPR) peak observed at ∼555 nm for Au, ∼435 nm for Ag and ∼510 nm for Au-Ag alloy. The XRD pattern shows fcc structure while the FTIR spectra indicate the presence of plant residues adsorbed on these NPs. Such a bio-capping of NPs is characterized by their weight loss, ∼35% due to thermal degradation of biomass, as observed in TG analysis. The colloidal dispersion of NPs is stable for about 6 weeks. The near spherical shape of NPs (ϕ20-50 nm) is observed by FE-SEM/TEM images and EDAX gives the expected elemental composition. Furthermore, these NPs showed enhanced antimicrobial activity (∼1-4-fold increase in zone of inhibition) in combination with antimicrobials against test strains. Thus, the phytosynthesized NPs could be used as effective growth inhibitors for various microorganisms.

  18. Leaching of Au, Ag, and Pd from waste printed circuit boards of mobile phone by iodide lixiviant after supercritical water pre-treatment.

    Science.gov (United States)

    Xiu, Fu-Rong; Qi, Yingying; Zhang, Fu-Shen

    2015-07-01

    Precious metals are the most attractive resources in waste printed circuit boards (PCBs) of mobile phones. In this work, an alternative process for recovering Au, Ag, and Pd from waste PCBs of mobile phones by supercritical water oxidation (SCWO) pre-treatment combined with iodine-iodide leaching process was developed. In the process, the waste PCBs of mobile phones were pre-treated in supercritical water, then a diluted hydrochloric acid leaching (HL) process was used to recovery the Cu, whose leaching efficiency was approximately 100%, finally the resulting residue was subjected to the iodine-iodide leaching process for recovering the Au, Ag, and Pd. Experimental results indicated that SCWO pre-treatment temperature, time, and pressure had significant influence on the Au, Ag, and Pd leaching from (SCWO+HL)-treated waste PCBs. The optimal SCWO pre-treatment conditions were 420°C and 60min for Au and Pd, and 410°C and 30min for Ag. The optimum dissolution parameters for Au, Pd, and Ag in (SCWO+HL)-treated PCBs with iodine-iodide system were leaching time of 120min (90min for Ag), iodine/iodide mole ratio of 1:5 (1:6 for Ag), solid-to-liquid ratio (S/L) of 1:10g/mL (1:8g/mL for Ag), and pH of 9, respectively. It is believed that the process developed in this study is environment friendly for the recovery of Au, Ag, and Pd from waste PCBs of mobile phones by SCWO pre-treatment combined with iodine-iodide leaching process. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Core–shell Au/Ag nanoparticles embedded in silicate sol–gel ...

    Indian Academy of Sciences (India)

    Administrator

    Dedicated to the memory of the late Professor S K Rangarajan. *For correspondence. Core–shell Au/Ag nanoparticles embedded in silicate sol–gel network for sensor .... An immediate colour change was observed for the mixed solution, indicating the dis- persion of metal nanoparticles in the MTMOS sol– gel matrix.

  20. Core-shell Au/Ag nanoparticles embedded in silicate sol-gel ...

    Indian Academy of Sciences (India)

    The electrocatalytic activity of core-shell Au100-Ag ( = 15, 27, 46, and 60) bimetallic nanoparticles embedded in methyl functionalized silicate MTMOS network towards the reduction of hydrogen peroxide was investigated by using cyclic voltammetry and chronoamperometric techniques. Core-shell Au/Ag bimetallic ...

  1. A fluorometric biosensor based on functional Au/Ag nanoclusters for real-time monitoring of tyrosinase activity.

    Science.gov (United States)

    Ao, Hang; Qian, Zhaosheng; Zhu, Yuyu; Zhao, Meizhi; Tang, Cong; Huang, Yuanyuan; Feng, Hui; Wang, Aijun

    2016-12-15

    Due to the vital role of tyrosinase in melanin biosynthesis and its function as an important biomarker for melanoma cancer, highly sensitive detection of its activity using biocompatible materials is in urgent demand. Herein we report a convenient and highly sensitive fluorometric biosensor for tyrosinase activity detection based on biocompatible dopamine-functionalized Au/Ag nanoclusters (Dopa-Au/Ag NCs). Dopamine with redox property was covalently linked to Au/Ag NCs surface and formed a Dopa-Au/Ag NCs bioconjugate with strong blue fluorescence. Dopamine is readily oxidized by molecular oxygen under the catalysis of tyrosinase. After dopamine is transformed to o-dopaquinone, an intraparticle photoinduced election transfer (PET) process occurs between Au/Ag NCs and o-dopaquinone moiety, leading to the fluorescence quenching of the Dopa-Au/Ag NCs bioconjugate. Thus, this biosensor was utilized for sensitive and selective detection of tyrosinase in terms of the relationship between fluorescence quenching efficiency and tyrosinase activity. This study discovers that Au/Ag NCs and dopaquinone can serve as a good electron acceptor and donor pair which results in an efficient intraparticle photoinduced electron transfer process, and also provides another alternative way for tyrosinase activity monitoring. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Fabricating a Homogeneously Alloyed AuAg Shell on Au Nanorods to Achieve Strong, Stable, and Tunable Surface Plasmon Resonances

    KAUST Repository

    Huang, Jianfeng

    2015-08-13

    Colloidal metal nanocrystals with strong, stable, and tunable localized surface plasmon resonances (SPRs) can be useful in a corrosive environment for many applications including field-enhanced spectroscopies, plasmon-mediated catalysis, etc. Here, a new synthetic strategy is reported that enables the epitaxial growth of a homogeneously alloyed AuAg shell on Au nanorod seeds, circumventing the phase segregation of Au and Ag encountered in conventional synthesis. The resulting core–shell structured bimetallic nanorods (AuNR@AuAg) have well-mixed Au and Ag atoms in their shell without discernible domains. This degree of mixing allows AuNR@AuAg to combine the high stability of Au with the superior plasmonic activity of Ag, thus outperforming seemingly similar nanostructures with monometallic shells (e.g., Ag-coated Au NRs (AuNR@Ag) and Au-coated Au NRs (AuNR@Au)). AuNR@AuAg is comparable to AuNR@Ag in plasmonic activity, but that it is markedly more stable toward oxidative treatment. Specifically, AuNR@AuAg and AuNR@Ag exhibit similarly strong signals in surface-enhanced Raman spectroscopy that are some 30-fold higher than that of AuNR@Au. When incubated with a H2O2 solution (0.5 m), the plasmonic activity of AuNR@Ag immediately and severely decayed, whereas AuNR@AuAg retained its activity intact. Moreover, the longitudinal SPR frequency of AuNR@AuAg can be tuned throughout the red wavelengths (≈620–690 nm) by controlling the thickness of the AuAg alloy shell. The synthetic strategy is versatile to fabricate AuAg alloyed shells on different shaped Au, with prospects for new possibilities in the synthesis and application of plasmonic nanocrystals.

  3. Highly open bowl-like PtAuAg nanocages as robust electrocatalysts towards ethylene glycol oxidation

    Science.gov (United States)

    Xu, Hui; Yan, Bo; Li, Shumin; Wang, Jin; Song, Pingping; Wang, Caiqin; Guo, Jun; Du, Yukou

    2018-04-01

    A novel combined seed mediated and galvanic replacement method has been demonstrated to synthesize a new class of trimetallic PtAuAg nanocatalysts with highly open bowl-like nanocage structure. The newly-generated PtAuAg nanocages catalysts exhibit superior electrocatalytic performances towards ethylene glycol oxidation with the mass activity of 6357.1 mA mg-1, 5.5 times higher than that of commercial Pt/C (1151.1 mA mg-1). This work demonstrates the first example of designing shape-controlled architectures of trimetallic bowl-like PtAuAg nanocages for liquid fuel electrooxidation.

  4. Au@Ag core/shell nanoparticles as colorimetric probes for cyanide sensing

    Science.gov (United States)

    Zeng, Jing-Bin; Cao, Ying-Ying; Chen, Jing-Jing; Wang, Xu-Dong; Yu, Jian-Feng; Yu, Bin-Bin; Yan, Zi-Feng; Chen, Xi

    2014-08-01

    We synthesize Au@Ag core/shell nanoparticles (NPs) using a Au NP assisted Tollens reaction. The as-synthesized NPs are used for the colorimetric cyanide sensing with a detection limit of 0.4 μM. The bimetallic NPs are immobilized into agarose gels as portable ``test strips''.We synthesize Au@Ag core/shell nanoparticles (NPs) using a Au NP assisted Tollens reaction. The as-synthesized NPs are used for the colorimetric cyanide sensing with a detection limit of 0.4 μM. The bimetallic NPs are immobilized into agarose gels as portable ``test strips''. Electronic supplementary information (ESI) available: Experimental procedures and Fig. S1-S14. See DOI: 10.1039/c4nr02560a

  5. High-performance ambipolar self-assembled Au/Ag nanowire based vertical quantum dot field effect transistor.

    Science.gov (United States)

    Song, Xiaoxian; Zhang, Yating; Zhang, Haiting; Yu, Yu; Cao, Mingxuan; Che, Yongli; Wang, Jianlong; Dai, Haitao; Yang, Junbo; Ding, Xin; Yao, Jianquan

    2016-10-07

    Most lateral PbSe quantum dot field effect transistors (QD FETs) show a low on current/off current (I on/I off) ratio in charge transport measurements. A new strategy to provide generally better performance is to design PbSe QD FETs with vertical architecture, in which the structure parameters can be tuned flexibly. Here, we fabricated a novel room-temperature operated vertical quantum dot field effect transistor with a channel of 580 nm, where self-assembled Au/Ag nanowires served as source transparent electrodes and PbSe quantum dots as active channels. Through investigating the electrical characterization, the ambipolar device exhibited excellent characteristics with a high I on/I off current ratio of about 1 × 10(5) and a low sub-threshold slope (0.26 V/decade) in the p-type regime. The all-solution processing vertical architecture provides a convenient way for low cost, large-area integration of the device.

  6. [Studies on Au-Ag-Pd-Cu alloys. (Part 3) Effects of additional elements to Au-Ag-Pd-Cu alloys (author's transl)].

    Science.gov (United States)

    Okazaki, K

    1981-01-01

    In the previous papers, the author pointed out that alloys containing 30 wt% Au, 15-25 wt% Pd and Cu were more favourable for Au-Ag-Pd-Cu quarternary dental alloys. In this paper, the experiments were carried out to find the effects of additional elements and so, Pt, Ir, Os, W, Mo, Cr, Mn, Co, Zn, In, Sn and Si were added to 30 wt% Au-30 wt% Ag-20 wt% Pd-20 wt% Cu alloys ranging 0.1 wt% to 2.0 wt% respectively. Then, tensile strength, elongation, hardness, corrosion resistivity and porosity ratio were tested on these specimen. Results were as follows. 1) The addition of 0.2 wt% Ir, 0.2 wt% Os and 1.0 wt% Co were comparatively effective for the fineness of grain sizes, elongation and tensile strength. 2) The addition of 0.2 wt% W, 1.0 wt% Mo and 0.2 wt% Si showed respectively bad effect for porosities or mechanical properties. 3) The addition of 1.0 wt% Cr, 2.0 wt% Mn, 1.0 wt% Co, 2.0 wt% Zn and 2.0 wt% In were good for the decrease of porosities respectively and showed that the porosity ratio was lower than 0.2%. 4) The additions of 2.0 wt% Zn-1.0 wt% Pt-0.5 wt% Co to Au-Ag-Pd-Cu alloy was especially good and showed 80 kg/mm2 of tensile strength, 5.1% of elongation, 249 of Vicker's hardness number and 0.4% of porosity ratio.

  7. An ultrasensitive sandwich-type electrochemical immunosensor based on the signal amplification strategy of echinoidea-shaped Au@Ag-Cu2O nanoparticles for prostate specific antigen detection.

    Science.gov (United States)

    Yang, Yuying; Yan, Qin; Liu, Qing; Li, Yongpeng; Liu, Hui; Wang, Ping; Chen, Lei; Zhang, Daopeng; Li, Yueyun; Dong, Yunhui

    2018-01-15

    Highly sensitive determination of tumor markers plays an important role in early diagnosis of cancer. Herein, a novel and ultrasensitive sandwich-type electrochemical immunosensor was fabricated for quantitative detection of prostate specific antigen (PSA). In this process, gold nanoparticles functionalized nitrogen-doped graphene quantum dots (Au@N-GQDs) was synthesized through a simple and green hydrothermal procedure to enhance conductivity, specific electrode surface area and quantity of immobilized primary antibodies (Ab 1 ). Subsequently, the prepared echinoidea-shaped nanocomposites (Au@Ag-Cu 2 O) composed of Au@Ag core-shell nanoparticles and disordered cuprous oxide were prepared successfully to label the secondary antibodies (Ab 2 ), which convened the advantages of good biocompatibility and high specific surface area. Because of the synergetic effect present in Au, Ag and Cu 2 O, the novel nanocomposites exhibited excellent electrocatalytic activity towards the reduction of hydrogen peroxide (H 2 O 2 ) for the amplified detection of PSA. Therefore, the as-proposed immunosensor for the detection of PSA possessed wide dynamic range from 0.01pg/mL to 100ng/mL with a low detection limit of 0.003pg/mL (S/N = 3). Furthermore, this sandwich-type immunosensor revealed high sensitivity, high selectivity and long-term stability, which had promising application in bioassay analysis. Copyright © 2017. Published by Elsevier B.V.

  8. Hollow Au/Ag nanostars displaying broad plasmonic resonance and high surface-enhanced Raman sensitivity

    Science.gov (United States)

    Garcia-Leis, Adianez; Torreggiani, Armida; Garcia-Ramos, Jose Vicente; Sanchez-Cortes, Santiago

    2015-08-01

    Bimetallic Au/Ag hollow nanostar (HNS) nanoparticles with different morphologies were prepared in this work. These nanoplatforms were obtained by changing the experimental conditions (concentration of silver and chemical reductors, hydroxylamine and citrate) and by using Ag nanostars as template nanoparticles (NPs) through galvanic replacement. The goal of this research was to create bimetallic Au/Ag star-shaped nanoparticles with advanced properties displaying a broader plasmonic resonance, a cleaner exposed surface, and a high concentration of electromagnetic hot spots on the surface provided by the special morphology of nanostars. The size, shape, and composition of Ag as well as their optical properties were studied by extinction spectroscopy, hyperspectral dark field microscopy, transmission and scanning electron microscopy (TEM and SEM), and energy dispersive X-ray spectroscopy (EDX). Finally, the surface-enhanced Raman scattering (SERS) activity of these HNS was investigated by using thioflavin T, a biomarker of the β-amyloid fibril formation, responsible for Alzheimer's disease. Lucigenin, a molecule displaying different SERS activities on Au and Ag, was also used to explore the presence of these metals on the NP surface. Thus, a relationship between the morphology, plasmon resonance and SERS activity of these new NPs was made.Bimetallic Au/Ag hollow nanostar (HNS) nanoparticles with different morphologies were prepared in this work. These nanoplatforms were obtained by changing the experimental conditions (concentration of silver and chemical reductors, hydroxylamine and citrate) and by using Ag nanostars as template nanoparticles (NPs) through galvanic replacement. The goal of this research was to create bimetallic Au/Ag star-shaped nanoparticles with advanced properties displaying a broader plasmonic resonance, a cleaner exposed surface, and a high concentration of electromagnetic hot spots on the surface provided by the special morphology of nanostars

  9. Laser synthesis of Au/Ag colloidal nano-alloys: Optical properties, structure and composition

    Energy Technology Data Exchange (ETDEWEB)

    Compagnini, Giuseppe [Dipartimento di Scienze Chimiche, Universita di Catania, Laboratorio Film Sottili e Nanostrutture, Viale A.Doria 6, Catania 95125 (Italy)], E-mail: gcompagnini@unict.it; Messina, Elena; Puglisi, Orazio [Dipartimento di Scienze Chimiche, Universita di Catania, Laboratorio Film Sottili e Nanostrutture, Viale A.Doria 6, Catania 95125 (Italy); Nicolosi, Valeria [Department of Physics, University of Dublin, Trinity College, Dublin 2 (Ireland)

    2007-12-15

    We have successfully synthesized Au/Ag colloidal nano-alloys with a wide range of compositions by laser ablation of single metal targets in water and a re-irradiation of mixed colloidal suspensions. The optical extinction spectra have been obtained in the plasmon resonance region and their analysis by using the Mie-Gans approach has lead to a quantitative estimation of a number of different structural features for the sols. Some of the obtained results are supported by X-ray photoelectron data and transmission electron microscopy, while others are used to investigate the kinetics of formation of the nano-alloys under laser irradiation.

  10. Synthesis of biocompatible AuAgS/Ag2S nanoclusters and their applications in photocatalysis and mercury detection

    International Nuclear Information System (INIS)

    Zhao, Qian; Chen, Shenna; Zhang, Lingyang; Huang, Haowen; Liu, Fengping; Liu, Xuanyong

    2014-01-01

    In this paper, a facile approach for preparation of AuAgS/Ag 2 S nanoclusters was developed. The unique AuAgS/Ag 2 S nanoclusters capped with biomolecules exhibit interesting excellent optical and catalytic properties. The fluorescent AuAgS/Ag 2 S nanoclusters show tunable luminescence depending on the nanocluster size. The apoptosis assay demonstrated that the AuAgS/Ag 2 S nanoclusters showed low cytotoxicity and good biocompatibility. Therefore, the nanoclusters can be used not only as a probe for labeling cells but also for their photocatalytic activity for photodegradation of organic dye. Moreover, a highly selective and sensitive assay for detection of mercury including Hg 2+ and undissociated mercury complexes was developed based on the quenching fluorescent AuAgS/Ag 2 S nanoclusters, which provides a promising approach for determining various forms of Hg in the mercury-based compounds in environment. These unique nanoclusters may have potential applications in biological labeling, sensing mercury, and photodegradation of various organic pollutants in waste water.Graphical Abstract

  11. Au-Ag hybrid nanoparticle patterns of tunable size and density on glass and polymeric supports.

    Science.gov (United States)

    Kruss, Sebastian; Srot, Vesna; van Aken, Peter A; Spatz, Joachim P

    2012-01-17

    This paper describes a method to pattern surfaces with Au-Ag hybrid nanoparticles. We used block copolymer micelle lithography of Au nanoparticles and electroless deposition of Ag. The combination of these two methods enables independent tuning of nanoparticle spacing and Ag-shell size. For this purpose, 8 nm large patterned Au nanoparticle seeds served as nuclei for the electroless deposition of silver that is based on a modified Tollens process with glucose. By adjusting the reaction conditions, specific growth of Ag on top of the Au seeds has been accomplished and analyzed by SEM, HRTEM, XEDS, and UV-vis spectroscopy. We could show that this versatile and green method is feasible on glass as well as on biomedical-relevant polymers like poly(ethylene glycol) hydrogels and amorphous Teflon. In conclusion, this method provides a new route to pattern glass and polymeric surfaces with Au-Ag hybrid nanoparticles. It will have many uses in applications such as surface enhanced Raman spectroscopy (SERS) or antimicrobial coatings for which hybrid nanoparticle density, size, and morphology are important. © 2011 American Chemical Society

  12. Stepwise synthesis of cubic Au-AgCdS core-shell nanostructures with tunable plasmon resonances and fluorescence.

    Science.gov (United States)

    Liu, Xiao-Li; Liang, Shan; Nan, Fan; Pan, Yue-Yue; Shi, Jun-Jun; Zhou, Li; Jia, Shuang-Feng; Wang, Jian-Bo; Yu, Xue-Feng; Wang, Qu-Quan

    2013-10-21

    Cubic Au-AgCdS core-shell nanostructures were synthesized through cation exchange method assisted by tributylphosphine (TBP) as a phase-transfer agent. Among intermediate products, Au-Ag core-shell nanocubes exhibited many high-order plasmon resonance modes related to the special cubic shape, and these plasmon bands red-shifted along with the increasing of particle size. The plasmon band of Au core first red-shifted and broadened at the step of Au-Ag₂S and then blue-shifted and narrowed at the step of Au-AgCdS. Since TBP was very crucial for the efficient conversion from Ag₂S to CdS, we found that both absorption and fluorescence of the final products could be controlled by TBP.

  13. Toward hybrid Au nanorods @ M (Au, Ag, Pd and Pt) core-shell heterostructures for ultrasensitive SERS probes

    Science.gov (United States)

    Xie, Xiaobin; Gao, Guanhui; Kang, Shendong; Lei, Yanhua; Pan, Zhengyin; Shibayama, Tamaki; Cai, Lintao

    2017-06-01

    Being able to precisely control the morphologies of noble metallic nanostructures is of essential significance for promoting the surface-enhanced Raman scattering (SERS) effect. Herein, we demonstrate an overgrowth strategy for synthesizing Au @ M (M = Au, Ag, Pd, Pt) core-shell heterogeneous nanocrystals with an orientated structural evolution and highly improved properties by using Au nanorods as seeds. With the same reaction condition system applied, we obtain four well-designed heterostructures with diverse shapes, including Au concave nanocuboids (Au CNs), Au @ Ag crystalizing face central cube nanopeanuts, Au @ Pd porous nanocuboids and Au @ Pt nanotrepangs. Subsequently, the exact overgrowth mechanism of the above heterostructural building blocks is further analysed via the systematic optimiziation of a series of fabrications. Remarkably, the well-defined Au CNs and Au @ Ag nanopeanuts both exhibit highly promoted SERS activity. We expect to be able to supply a facile strategy for the fabrication of multimetallic heterogeneous nanostructures, exploring the high SERS effect and catalytic activities.

  14. Aqueous phase synthesis of Au-Ag core-shell nanocrystals with tunable shapes and their optical and catalytic properties.

    Science.gov (United States)

    Tsao, Yu-Chi; Rej, Sourav; Chiu, Chun-Ya; Huang, Michael H

    2014-01-08

    In this study, rhombic dodecahedral gold nanocrystals were used as cores for the generation of Au-Ag core-shell nanocrystals with cubic, truncated cubic, cuboctahedral, truncated octahedral, and octahedral structures. Gold nanocrystals were added to an aqueous mixture of cetyltrimethylammonium chloride (CTAC) surfactant, AgNO3, ascorbic acid, and NaOH to form the core-shell nanocrystals. The nanocrystals are highly uniform in size and shape, and can readily self-assemble into ordered packing structures on substrates. Results from observation of solution color changes and variation in the reaction temperature suggest octahedra are produced at a higher growth rate, while slower growth favors cube formation. The major localized surface plasmon resonance (LSPR) band positions for these nanocrystals are red-shifted compared to those for pristine silver particles with similar dimensions due to the LSPR effect from the gold cores. By increasing the concentrations of reagents, Au-Ag core-shell cubes and octahedra with tunable sizes were obtained. Au-Ag cubes with body diagonals of 130, 144, and 161 nm and octahedra with body diagonals of 113, 126, and 143 nm have been prepared, allowing the investigation of size effect on their optical properties. Au-Ag octahedra with thinner Ag shells (12-16.5 nm) exhibit a blue-shifted major LSPR band relative to the LSPR band at 538 nm for the gold cores. For Au-Ag octahedra and cubes with thicker shells (22.5-37 nm), the major LSPR band is progressively red-shifted from that of the gold cores with increasing shell thickness and particle size. The Au-Ag octahedra show higher catalytic activity than cubes toward reduction of 2-amino-5-nitrophenol by NaBH4 at 30 °C, but both particle shapes display significantly enhanced catalytic efficiency at 40 °C.

  15. Characterizing the economic value of an epithermal Au-Ag ore with Laser Induced Breakdown Spectroscopy (LIBS)

    NARCIS (Netherlands)

    Dalm, M.; Buxton, M.W.N.

    2016-01-01

    LIBS was applied to 19 Au-Ag ore samples to investigate if this technique can be used to distinguish between economic and sub-economic ore either by direct detection of these elements or by using other elements as indicators. However, the Au and Ag grades of the samples are below the detection limit

  16. Surface enhanced Raman spectroscopic studies on magnetic Fe3O4@AuAg alloy core-shell nanoparticles

    Science.gov (United States)

    Sun, Hai-Long; Xu, Min-Min; Guo, Qing-Hua; Yuan, Ya-Xian; Shen, Li-Ming; Gu, Ren-Ao; Yao, Jian-Lin

    2013-10-01

    A facile approach has been developed to fabricate multifunctional Fe3O4@AuAg alloy core-shell nanoparticles, owning the magnetism of the core and the surface enhanced Raman spectroscopy (SERS) activities of the alloy shell. By changing the amount of HAuCl4 and AgNO3, Fe3O4@AuAg alloy nanoparticles with different component ratios of Au and Ag were successfully prepared. The surface plasmon resonance of the composition was linearly tuned in a wide range by varying the molar fraction of Ag and Au, suggesting the formation of AuAg alloy shell. SERS and magnetic enrichment effects were investigated by using thiophenol (TP) as the probe molecule. The SERS intensity was strongly dependent on the molar ratios of Au and Ag and the excitation line. Enrichment for the molecules with low concentration and on line SERS monitoring experiments were performed through combining the magnetism of the core and the SERS effect of the alloy shell. The results revealed that the magnetic enrichment efficiency was dramatically increased due to the strong magnetism of Fe3O4 core. In addition, the Fe3O4@AuAg nanoparticles were also used in the microfluidic chip to continuously detect different flowing solution in the channel. The detection time and amount of analyte were successfully decreased.

  17. Synthesis of bimetallic Au-Ag alloyed mesocomposites and their catalytic activity for the reduction of nitroaromatics

    Science.gov (United States)

    Sareen, Shweta; Mutreja, Vishal; Pal, Bonamali; Singh, Satnam

    2018-03-01

    Homogeneously dispersed Au-Ag alloyed nanostructures varying from spherical (6-8 nm) to rod shape (aspect ratio ∼15-20 nm) were synthesized within the channels of amine modified mesoporous SBA-15 using post modification. Formation of alloy nanostructures for varying Au-Ag loadings have been supported by XPS and elemental mapping studies. Furthermore, changes in the surface/electronic properties of mesocomposites as a function of increased bimetallic Au:Ag loading have been elucidated with the help of XRD, BET, TEM and XPS studies respectively. It was found that synergism owing to electronic interplay between Au and Ag species concurrently improved the catalytic activity of bimetallic nanocomposites. Among the various monometallic and bimetallic mesocomposites, Au-Ag (5:1)/m-SBA-15 nanocomposites exhibited the best catalytic activity (k = 2.12 × 10-2 min-1 and 3.99 × 10-2 min-1) for the selective reduction of nitrobenzene to aniline and p-nitroacetophenone to p-aminoacetophenone respectively.

  18. β-Cyclodextrin coated SiO₂@Au@Ag core-shell nanoparticles for SERS detection of PCBs.

    Science.gov (United States)

    Lu, Yilin; Yao, Guohua; Sun, Kexi; Huang, Qing

    2015-09-07

    A new type of surface-enhanced Raman scattering (SERS) substrate consisting of β-cyclodextrin (β-CD) coated SiO2@Au@Ag nanoparticles (SiO2@Au@Ag@CD NPs) has been achieved. Our protocol was a simplified approach as the fabrication and modification of the silver shell were realized in a single-step reaction by taking advantage of β-CD as both the reducing and stabilizing agents. The as-synthesized SiO2@Au@Ag@CD NPs were uniform in size and demonstrated high SERS activity and reproducibility. The substrates consisting of the SiO2@Au@Ag@CD NPs were employed for SERS detection of polychlorinated biphenyls (PCBs) including PCB-3, PCB-29 and PCB-77. The SERS detection sensitivity was significantly improved due to enrichment of more PCB molecules captured by β-CD on the substrate surface, as confirmed by the appearance of the new Raman bands which are attributed to the complexes between β-CD and PCBs according to the theoretical simulation. Therefore, this work presents a novel approach to the fabrication of effective SERS substrates that can be employed for rapid determination of trace amounts of PCBs in the environment with high detection sensitivity and recognition selectivity.

  19. Functionalized Au@Ag-Au nanoparticles as an optical and SERS dual probe for lateral flow sensing.

    Science.gov (United States)

    Bai, Tingting; Wang, Meng; Cao, Min; Zhang, Juan; Zhang, Kangzhen; Zhou, Ping; Liu, Zhengxia; Liu, Ying; Guo, Zhirui; Lu, Xiang

    2018-02-14

    Lateral flow assay strips (LFASs) with Au nanoparticles (NPs) have been widely used as a probe for biomarkers in point-of-care testing; however, there still remain challenges in detection sensitivity and quantitative analysis. In this study, we developed a surface-enhanced Raman scattering (SERS)-based LFAS for quantitative analysis of a biomarker in the low concentration range. Moreover, apart from conventional Au NPs, three other types of citrate-capped Au-Ag bimetallic NPs: Au core with Ag shell NPs (Au@Ag NPs), rattle-like Au core in Ag-Au shell NPs (Au@Ag-Au NPs) and Ag-Au NPs were prepared and functionalized, and their solution-based SERS activities were comprehensively studied by experimental measurement and theoretical analysis. The results clearly indicated that the citrate-capped Au@Ag-Au NPs exhibited the highest SERS activity among the probes tested. Au@Ag-Au NPs were used as both optical and SERS probes in a SERS-based LFAS. In the presence of the analyte at high concentrations, a purple color appeared in the test zone. Highly sensitive and quantitative analysis was realized by measurement of SERS signals from the test lines. One of the most specific markers for cardiac injury, cardiac troponin I (cTnI), was chosen as the detection model. The detection limit of the SERS-based LFAS for cardiac troponin I was 0.09 ng/mL, lowered by nearly 50 times compared with visual results, and could be further lowered by optimization. These results demonstrated that the SERS-based LFAS using citrate-capped Au@Ag-Au NPs as probes can be a powerful tool for highly sensitive and quantitative detection of biomarkers. Graphical abstract A surface-enhanced Raman scattering (SERS)-based lateral flow assay strip using rattle-like Au core in Ag-Au shell (Au@Ag-Au) nanoparticles as probes was developed for quantitative analysis of a biomarker, with a detection limit nearly 50 times lower than that of visual assessment. C control line, T test line.

  20. A nanocomposite of Au-AgI core/shell dimer as a dual-modality contrast agent for x-ray computed tomography and photoacoustic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Orza, Anamaria; Wu, Hui; Li, Yuancheng; Mao, Hui, E-mail: hmao@emory.edu, E-mail: Xiangyang.Tang@emory.edu [Department of Radiology and Imaging Sciences and Center for Systems Imaging, Emory University School of Medicine, Atlanta, Georgia 30322 (United States); Yang, Yi; Tang, Xiangyang, E-mail: hmao@emory.edu, E-mail: Xiangyang.Tang@emory.edu [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30322 (United States); Feng, Ting; Wang, Xueding [Department of Biomedical Engineering, University of Michigan School of Medicine, Ann Arbor, Michigan 48109 (United States); Yang, Lily [Department of Surgery, Emory University School of Medicine, Atlanta, Georgia 30322 (United States)

    2016-01-15

    Purpose: To develop a core/shell nanodimer of gold (core) and silver iodine (shell) as a dual-modal contrast-enhancing agent for biomarker targeted x-ray computed tomography (CT) and photoacoustic imaging (PAI) applications. Methods: The gold and silver iodine core/shell nanodimer (Au/AgICSD) was prepared by fusing together components of gold, silver, and iodine. The physicochemical properties of Au/AgICSD were then characterized using different optical and imaging techniques (e.g., HR- transmission electron microscope, scanning transmission electron microscope, x-ray photoelectron spectroscopy, energy-dispersive x-ray spectroscopy, Z-potential, and UV-vis). The CT and PAI contrast-enhancing effects were tested and then compared with a clinically used CT contrast agent and Au nanoparticles. To confer biocompatibility and the capability for efficient biomarker targeting, the surface of the Au/AgICSD nanodimer was modified with the amphiphilic diblock polymer and then functionalized with transferrin for targeting transferrin receptor that is overexpressed in various cancer cells. Cytotoxicity of the prepared Au/AgICSD nanodimer was also tested with both normal and cancer cell lines. Results: The characterizations of prepared Au/AgI core/shell nanostructure confirmed the formation of Au/AgICSD nanodimers. Au/AgICSD nanodimer is stable in physiological conditions for in vivo applications. Au/AgICSD nanodimer exhibited higher contrast enhancement in both CT and PAI for dual-modality imaging. Moreover, transferrin functionalized Au/AgICSD nanodimer showed specific binding to the tumor cells that have a high level of expression of the transferrin receptor. Conclusions: The developed Au/AgICSD nanodimer can be used as a potential biomarker targeted dual-modal contrast agent for both or combined CT and PAI molecular imaging.

  1. Enzyme-free hydrogen peroxide sensor based on Au@Ag@C core-double shell nanocomposites

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yancai, E-mail: liyancai@mnnu.edu.cn [College of Chemistry & Environment, Minnan Normal University, Zhangzhou 363000 (China); Fujian Province Key Laboratory of Modern Analytical Science and Separation Technology, Minnan Normal University, Zhangzhou 363000 (China); Zhang, Yayun; Zhong, Yanmei [College of Chemistry & Environment, Minnan Normal University, Zhangzhou 363000 (China); Li, Shunxing [College of Chemistry & Environment, Minnan Normal University, Zhangzhou 363000 (China); Fujian Province Key Laboratory of Modern Analytical Science and Separation Technology, Minnan Normal University, Zhangzhou 363000 (China)

    2015-08-30

    Graphical abstract: - Highlights: • A facile method was designed to synthesize Au@Ag@C core-double shell nanocomposites. • Carbon nanomaterials at the outermost layer could protect Au and Ag nanoparticles from oxidation and aggregation. • The Au@Ag@C core-double shell nanocomposites showed high sensitivity and selectivity to electrocatalytic reduction of hydrogen peroxide. • The hydrogen peroxide sensor has a wide linear range of 5.0 μM to 4.75 mM and a limit of detection as low as 0.14 μM. - Abstract: The well-designed Au@Ag@C core-double shell nanocomposites were synthesized via a facile method, and were used to fabricate an enzyme-free amperometric hydrogen peroxide (H{sub 2}O{sub 2}) sensor. The size, shape, elementary composition and structure of the nanocomposites were characterized by transmission electron microscope (TEM), energy-dispersed spectrum (EDS) and X-ray diffraction (XRD). The outermost layer of the nanocomposites was amorphous carbon, the second layer was Ag and the core was Au. The Au@Ag@C core-double shell nanocomposites exhibit attractive activity for electrocatalytic reduction of H{sub 2}O{sub 2} according to the electrochemical experiments. It also demonstrates the H{sub 2}O{sub 2} sensor possess well performance with a wide linear range of 5.0 μM to 4.75 mM and a limit of detection (LOD) as low as 0.14 μM (S/N = 3). Furthermore, the interference from the common interfering species, such as glucose, ascorbic acid, dopamine and uric acid can be effectively avoided. In a word, the Au@Ag@C nanocomposites are promising candidates for enzyme-free H{sub 2}O{sub 2} sensor.

  2. Rough surface Au@Ag core-shell nanoparticles to fabricating high sensitivity SERS immunochromatographic sensors.

    Science.gov (United States)

    Fu, Qiangqiang; Liu, Hongwu Liu; Wu, Ze; Liu, An; Yao, Cuize; Li, Xiuqing; Xiao, Wei; Yu, Shiting; Luo, Zhi; Tang, Yong

    2015-11-14

    Immunochromatographic sensors (ICSs) are inexpensive, simple, portable, and robust, thus making ICSs commonplace in clinical diagnoses, food testing, and environmental monitoring. However, commonly used gold nanoparticles (AuNPs) ICSs have low sensitivity. Therefore, we developed highly sensitive surface enhanced Raman scattering (SERS) ICSs. To enhance the sensitivity of SERS ICSs, rough surface core-shell Au@Ag nanoparticles (RSAu@AgNPs) were prepared by coating silver on the surface of gold nanoflowers (AuNFs). Then these nanoparticles were used as SERS substrate in the SERS ICSs, after which the SERS ICSs were implemented to detect haemoglobin and heavy metal cadmium ion (Cd(2+)). The limit of detection (LOD) of the SERS ICSs for detecting haemoglobin was 8 ng/mL, and the linear range of the SERS ICSs was from 31.3 to 2000 ng/mL. The LOD of the SERS ICSs for detecting Cd(2+) was 0.05 ng/mL and the linear analysis range was from 0.05 to 25 ng/mL. The cross reactivity of the SERS ICSs was studied and results showed that the SERS ICSs exhibited highly specific for detection of haemoglobin and Cd(2+), respectively. The SERS ICSs were then used to detect haemoglobin (spiked in serum and in stool) and Cd(2+) (spiked in tap water, river water, and soil leaching water), and the results showed high recovery. These characteristics indicated that SERS ICSs were ideal tools for clinical diagnosis and environmental pollution monitoring.

  3. Synthesis of Au@Ag core-shell nanocubes containing varying shaped cores and their localized surface plasmon resonances.

    Science.gov (United States)

    Gong, Jianxiao; Zhou, Fei; Li, Zhiyuan; Tang, Zhiyong

    2012-06-19

    We have synthesized Au@Ag core-shell nanocubes containing Au cores with varying shapes and sizes through modified seed-mediated methods. Bromide ions are found to be crucial in the epitaxial growth of Ag atoms onto Au cores and in the formation of the shell's cubic shape. The Au@Ag core-shell nanocubes exhibit very abundant and distinct localized surface plasmon resonance (LSPR) properties, which are core-shape and size-dependent. With the help of theoretical calculation, the physical origin and the resonance mode profile of each LSPR peak are identified and studied. The core-shell nanocrystals with varying shaped cores offer a new rich category for LSPR control through the plasmonic coupling effect between core and shell materials.

  4. Characterizing the economic value of an epithermal Au-Ag ore with Laser Induced Breakdown Spectroscopy (LIBS)

    OpenAIRE

    Dalm, M.; Buxton, M.W.N.

    2016-01-01

    LIBS was applied to 19 Au-Ag ore samples to investigate if this technique can be used to distinguish between economic and sub-economic ore either by direct detection of these elements or by using other elements as indicators. However, the Au and Ag grades of the samples are below the detection limit of the LIBS setup that was used. Furthermore, sample heterogeneity imposed difficulties for extracting quantitative compositional information from LIBS spectra due to signal intensity variations a...

  5. Au@Ag core-shell nanocubes with finely tuned and well-controlled sizes, shell thicknesses, and optical properties.

    Science.gov (United States)

    Ma, Yanyun; Li, Weiyang; Cho, Eun Chul; Li, Zhiyuan; Yu, Taekyung; Zeng, Jie; Xie, Zhaoxiong; Xia, Younan

    2010-11-23

    This paper describes a facile method for generating Au@Ag core-shell nanocubes with edge lengths controllable in the range of 13.4-50 nm. The synthesis involved the use of single-crystal, spherical Au nanocrystals of 11 nm in size as the seeds in an aqueous system, with ascorbic acid serving as the reductant and cetyltrimethylammonium chloride (CTAC) as the capping agent. The thickness of the Ag shells could be finely tuned from 1.2 to 20 nm by varying the ratio of AgNO(3) precursor to Au seeds. We also investigated the growth mechanism by examining the effects of seeds (capped by CTAC or cetyltrimethylammonium bromide(CTAB)) and capping agent (CTAC vs CTAB) on both size and shape of the resultant core-shell nanocrystals. Our results clearly indicate that CTAC worked much better than CTAB as a capping agent in both the syntheses of Au seeds and Au@Ag core-shell nanocubes. We further studied the localized surface plasmon resonance properties of the Au@Ag nanocubes as a function of the Ag shell thickness. By comparing with the extinction spectra obtained from theoretical calculations, we derived a critical value of ca. 3 nm for the shell thickness at which the plasmon excitation of the Au cores would be completely screened by the Ag shells. Moreover, these Au@Ag core-shell nanocubes could be converted into Au-based hollow nanostructures containing the original Au seeds in the interiors through a galvanic replacement reaction.

  6. Fluid inclusion chemistry of adularia-sericite epithermal Au-Ag deposits of the southern Hauraki Goldfield, New Zealand

    Science.gov (United States)

    Simpson, Mark P.; Strmic Palinkas, Sabina; Mauk, Jeffrey L.; Bodnar, Robert J.

    2015-01-01

    Microthermometry, laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS), and Raman spectroscopy have been used to determine the temperature, apparent salinity, and composition of individual fluid inclusions in adularia-sericite Au-Ag epithermal veins from the Karangahake, Martha, Favona, and Waitekauri deposits, southern Hauraki goldfield, New Zealand. Quartz veins contain colloform to crustiform bands that alternate with coarse-grained quartz and amethyst. The ore mineralization occurs only in colloform to crustiform bands.

  7. Study of Ag induced bimetallic (Au-Ag) nanowires on silicon (5 5 12) surfaces: Experiment and theoretical aspects

    Science.gov (United States)

    Bhukta, Anjan; Bagarti, Trilochan; Guha, Puspendu; Ravulapalli, Sathyavathi; Satpati, Biswarup; Rakshit, Bipul; Maiti, Paramita; Parlapalli, Venkata Satyam

    2017-10-01

    The reconstructed vicinal (high index) silicon surfaces, such as, Si (5 5 12) composes row-like structures that can be used as templates for growing aligned nanowires. By using a sub-monolayers of Ag, prior to Au deposition on reconstructed Si (5 512) surface, intermixing of Au and Ag, enhancement of aspect ratio of bimetallic Au-Ag nanowires with tunable morphology is reported. This is attributed to a combined effect of pre-grown Ag strips as nucleation centers for incoming Au ad-atoms and anisotropic Au-Ag intermixing. To achieve optimum conditions for the growth of larger aspect ratio Au-Ag nanostructures, the growth kinetics have been studied by varying growth and annealing temperatures. At ≈400 °C, the Ag diffused into silicon substrate and the inter-diffusion found to inhibit the formation of Au-Ag bimetallic nanostructures. Controlled experiments under ultra-high vacuum condition in a molecular beam epitaxy system and in-situ scanning tunneling microscopy measurements along with ex-situ scanning transmission and secondary electron microscopy measurements have been carried out to understand the bimetallic nanostructure growth. Kinetic Monte Carlo (KMC) simulations based on kinematics of ad-atoms on an anisotropic template with a solid on solid model in which the relative ratios of binding energies (that are obtained from the Density Functional Theory) have been used and the KMC simulations results agree with the experimental observations. Advantage of having bimetallic structures as effective substrates for Surface enhanced Raman spectroscopy application is demonstrated by detecting Rhodamine 6 G (R6G) molecule at the concentration of 10-7M.

  8. Au crystal growth on natural occurring Au-Ag aggregate elucidated by means of precession electron diffraction (PED)

    Science.gov (United States)

    Roqué Rosell, Josep; Portillo Serra, Joaquim; Aiglsperger, Thomas; Plana-Ruiz, Sergi; Trifonov, Trifon; Proenza, Joaquín A.

    2018-02-01

    In the present work, a lamella from an Au-Ag aggregate found in Ni-laterites has been examined using Transmission Electron Microscope to produce a series of Precision Electron Diffraction (PED) patterns. The analysis of the structural data obtained, coupled with Energy Dispersive X-ray microanalysis, made it possible to determine the orientation of twinned native gold growing on the Au-Ag aggregate. The native Au crystal domains are found to have grown at the outermost part of the aggregate whereas the inner core of the aggregate is an Au-Ag alloy (∼4 wt% Ag). The submicron structural study of the natural occurring Au aggregate points to the mobilization and precipitation of gold in laterites and provides insights on Au aggregates development at supergene conditions. This manuscript demonstrates the great potential of electron crystallographic analysis, and in particular, PED to study submicron structural features of micron sized mineral aggregates by using the example of a gold grain found in a Ni-laterite deposits.

  9. Effect of Refractive Index of Substrate on Fabrication and Optical Properties of Hybrid Au-Ag Triangular Nanoparticle Arrays

    Directory of Open Access Journals (Sweden)

    Jing Liu

    2015-05-01

    Full Text Available In this study, the nanosphere lithography (NSL method was used to fabricate hybrid Au-Ag triangular periodic nanoparticle arrays. The Au-Ag triangular periodic arrays were grown on different substrates, and the effect of the refractive index of substrates on fabrication and optical properties was systematically investigated. At first, the optical spectrum was simulated by the discrete dipole approximation (DDA numerical method as a function of refractive indexes of substrates and mediums. Simulation results showed that as the substrates had the refractive indexes of 1.43 (quartz and 1.68 (SF5 glass, the nanoparticle arrays would have better refractive index sensitivity (RIS and figure of merit (FOM. Simulation results also showed that the peak wavelength of the extinction spectra had a red shift when the medium’s refractive index n increased. The experimental results also demonstrated that when refractive indexes of substrates were 1.43 and 1.68, the nanoparticle arrays and substrate had better adhesive ability. Meanwhile, we found the nanoparticles formed a large-scale monolayer array with the hexagonally close-packed structure. Finally, the hybrid Au-Ag triangular nanoparticle arrays were fabricated on quartz and SF5 glass substrates and their experiment extinction spectra were compared with the simulated results.

  10. Facile one-pot green synthesis of Au-Ag alloy nanoparticles using sucrose and their composition-dependent photocatalytic activity for the reduction of 4-nitrophenol.

    Science.gov (United States)

    Sun, Li; Yin, Yuechao; Wang, Fa; Su, Wenxian; Zhang, Lixin

    2018-03-28

    Au-Ag alloy nanoparticles (NPs) less than 10 nm in size were synthesized using sucrose as a reductant and surfactant. Au-Ag alloy NPs with a homogeneous composition were continuously obtained by changing the synthesis time from 2 to 40 min in one pot. Based on the UV-Vis, ICP, TEM, HR-TEM, EDX and SAED analyses, the synthesis mechanism of Au-Ag alloy NPs was deduced. Under hydrolysis conditions, sucrose showed a stronger reducibility compared with glucose, fructose and their mixture. And the as-prepared Au-Ag alloy NPs exhibited a superior photocatalytic activity and stability for the reduction of 4-nitrophenol due to the abundant hydroxyl groups of sucrose and the synergistic effect between Au and Ag elements. The rate constant of 4-nitrophenol reduction could be linearly controlled by the composition of Au-Ag alloy NPs or their synthesis time. It was indicated that the photocatalytic activity of Au-Ag alloy NPs could be predetermined as early as their synthesis process. The above methods of controlling the rate constant provide promising routes for other photocatalytic reactions using bimetallic NPs as photocatalysts.

  11. DEFORMATION INFLUENCE ON A LIFETIME OF WELDING ELECTRODE TIPS

    Directory of Open Access Journals (Sweden)

    Ján Viňáš

    2009-02-01

    Full Text Available The contribution deals with the influence of welding electrode tips deformation on their lifetime. The influence of material properties, production technology and the intensity of welding electrodes load on their lifetime are presented. The electrode tips of the most used type of CuCr1Zr alloy of three basic standard shapes before and after the process of welding are evaluated. The process of welding is realized with low, middle and maximum welding parameters on programmable pneumatic spot welding machine VTS BPK 20. The influence of welding parameters on chosen material characteristics of welding tips is observed. Through the use of upsetting test, dependency of forming strength and deformation of material on used technology of welding tip production is observed.

  12. Study of helium diffusion, implanted at a cyclotron, in face-centered cubic metals: Au, Ag and Al

    International Nuclear Information System (INIS)

    Sciani, V.

    1985-01-01

    Helium in metals is produced by nuclear reactions of energetic particles. In nuclear technology the interest on helium in metals is import, due to its production by (n, α) reaction. Because helium has extremely low solubility in metals, the precipitation in the form of filled bubbles at elevated temperatures occurs, which have detrimental effects on mechanical properties and may limit the lifetime of structural components. One typical example is the high temperature embrittlement. The nucleation and growth of the bubbles strongly depends on the mobility of the helium. This work presents the study of helium diffusion in Au, Ag and Al at temperatures above room temperature. The helium created by (n, α) reactions has been simulated by homogeneous alpha particles implantation in cyclotron, at room temperature, in specimens of thicknesses between 5 and 50 μm and helium concentration between 10 -3 to 10 ppm. After implantation, the specimens were dropped in a furnace in a UHV-chamber and the diffusion was measured by observing the He-release during linear and isothermal annealings. The occurence of free diffusion was comparing the dependence of release kinetics on helium concentration, sample thickness, time and heating rate to diffusion theory and is clearly separeted from agglomeration process. The diffusion constants of helium in Au, Ag and Al follow an Arrhenius behavior, with: Au:D o =10 -1.0 cm 2 /s ΔH=1.70eV Ag:D 0 =10 -1.2 cm 2 /s ΔH=1.51eV Al:D o =10 +0.5 cm 2 /s ΔH=1.40eV. The results are compared to self-diffusion and to the diffusion of other gases in these metals. Comparison with theoretical estimates favours the vacancy mechanism for helium diffusion in Au, Ag and Al. (author) [pt

  13. Silica-covered star-shaped Au-Ag nanoparticles as new electromagnetic nanoresonators for Raman characterisation of surfaces

    Science.gov (United States)

    Krajczewski, Jan; Kołątaj, Karol; Pietrasik, Sylwia; Kudelski, Andrzej

    2018-03-01

    One of the tools used for determining the composition of surfaces of various materials is shell-isolated nanoparticle-enhanced Raman spectroscopy (SHINERS). SHINERS is a modification of "standard" surface-enhanced Raman spectroscopy (SERS), in which, before Raman spectra are recorded, the surfaces analysed are covered with a layer of plasmonic nanoparticles protected by a very thin layer of a transparent dielectric. The plasmonic cores of the core-shell nanoparticles used in SHINERS measurements generate a local enhancement of the electric field of the incident electromagnetic radiation, whereas the transparent coatings prevent the metal cores from coming into direct contact with the material being analysed. In this contribution, we propose a new type of SHINERS nanoresonators that contain spiky, star-shaped metal cores (produced from a gold/silver alloy). These spiky, star-shaped Au-Ag nanoparticles have been covered by a layer of silica. The small radii of the ends of the tips of the spikes of these plasmonic nanostructures make it possible to generate a very large enhancement of the electromagnetic field there, with the result that such SHINERS nanoresonators are significantly more efficient than the standard semi-spherical nanostructures. The Au-Ag alloy nanoparticles were synthesised by the reduction of a solution containing silver nitrate and chloroauric acid by ascorbic acid. The final geometry of the nanostructures thus formed was controlled by changing the ratio between the concentrations of AuCl4- and Ag+ ions. The shape of the synthesised star-shaped Au-Ag nanoparticles does not change significantly during the two standard procedures for depositing a layer of silica (by the decomposition of sodium silicate or the decomposition of tetraethyl orthosilicate).

  14. [Studies on Au-Ag-Pd-Cu alloys. (Part 2) Some properties on alloys containing 30 wt% Au (author's transl)].

    Science.gov (United States)

    Okazaki, K

    1980-04-01

    In the previous paper, the author reported 30 wt% Au was more favourable content in Au-Ag-Pd-Cu quaternary dental alloys. In this paper, the experiment was carried out to find suitable Pd and Cu content in 30 wt% Au-Ag-Pd-Cu alloy. Pd and Cu content was changed from 5 wt% to 25 wt% and from 10 wt% to 20 wt% respectively. Ag content was balanced, and no other metals was added. Range of solidification temperature, tensile strength, elongation, hardness, corrosion resistivity and castability were tested. Results were as follows. 1) In these alloys, liquidus points were in the range of 880 degree C approximately 140 degree C, but in the majority of alloys, liquidus points were under 1100 degree C. Range of solidification temperature was more narrow in 20 wt% Cu than other Cu content. 2) The tensile strength and elongation of swaged specimens increased as Pd content increased, but in case of cast specimens, mechanical properties were the highest at 15 approximately 20 wt% Pd. The Vicker's hardness was in the range of 116 to 235. 3) The corrosion test in 0.1% Na2S solution indicated that the corrosion resistance was increased with Pd content and alloys contained more than 20 wt% Pd showed good resistance to corrosion. 4) The castability was affected by the Pd content and much decreased between 15 wt% Pd and 20 wt% Pd, but the castability of these alloys is twice as good as the alloys on the market. From these results, it seemed that the alloys containing 15 approximately 20 wt% Pd and 15 approximately 25 wt% Cu were more favourable composition to 30 wt% Au-Ag-Pd-Cu alloys.

  15. Au@Ag Core-Shell Nanocubes with Finely Tuned and Well-Controlled Sizes, Shell Thicknesses, and Optical Properties

    OpenAIRE

    Ma, Yanyun; Li, Weiyang; Cho, Eun Chul; Li, Zhiyuan; Yu, Taekyung; Zeng, Jie; Xie, Zhaoxiong; Xia, Younan

    2010-01-01

    This paper describes a facile method for generating Au@Ag core-shell nanocubes with edge lengths controllable in the range of 13.4 to 50 nm. The synthesis involved the use of single-crystal, spherical Au nanocrystals of 11 nm in size as the seeds in an aqueous system, with ascorbic acid serving as the reductant and cetyltrimethylammonium chloride (CTAC) as the capping agent. The thickness of the Ag shells could be finely tuned from 1.2 to 20 nm by varying the ratio of AgNO3 precursor to Au se...

  16. Phase formation study of noble metal (Au, Ag and Pd) doped lanthanum perovskites synthesized by hydrothermal method

    Energy Technology Data Exchange (ETDEWEB)

    Nikam, Shrikant K. [Department of Chemistry, Savitribai Phule Pune University, Pune 411007 (India); Anantrao Thopte College, Bhor, Pune 412206 (India); Athawale, Anjali A., E-mail: agbed@chem.unipune.ac.in [Department of Chemistry, Savitribai Phule Pune University, Pune 411007 (India)

    2015-04-01

    Noble metal (Au, Ag and Pd) doped Lanthanum perovskites (LaMnO{sub 3}, LaCrO{sub 3} and LaFeO{sub 3}) have been synthesized by hydrothermal method. The effect of dopant and their concentration on the phase purity, crystallite size, morphology and magnetic character of the synthesized perovskites were systematically studied by FTIR spectroscopy, XRD, TGA, SEM, ICP-AES and VSM. The results show that phase pure products were obtained only after calcining the hydrothermally synthesized products above 760 °C for a minimum of 6 h. Nature and concentration of the dopant plays an important role in determining the phase formation temperature, morphology and magnetic character. The dopant ion preferentially occupies A-site and homogeneous phase of product is obtained upto a dopant concentration of 4%, higher concentration results in phase separation. The products exhibit spherical morphology. Lanthanum ferrite shows ferromagnetic nature, while the doped samples show weak magnetic properties. - Highlights: • Hydrothermal synthesis of noble metal doped lanthanum perovskites. • Site preference of noble metal (Au, Ag and Pd) doping in LaBO{sub 3} (B = Mn, Cr and Fe). • Dopant ions affect the phase formation temperature and morphology the perovskites. • 4% appears to be the maximum limit of doping at A-site.

  17. Facile construction of fascinating trimetallic PdAuAg nanocages with exceptional ethylene glycol and glycerol oxidation activity.

    Science.gov (United States)

    Xu, Hui; Wang, Jin; Yan, Bo; Li, Shumin; Wang, Caiqin; Shiraishi, Yukihide; Yang, Ping; Du, Yukou

    2017-11-09

    Highly open metallic nanocages represent a novel class of nanostructures for advanced catalytic applications in direct liquid fuels cells due to their specific capability of providing easy access to reactants in both internal and external active sites and also desirable electronic structures for the adsorption of molecules, which render superior catalytic performances. However, to date, the rational design of trimetallic nanocages with tunable compositions remains a challenge. Herein, we demonstrate a facile method combining seed mediated and galvanic replacement for the preparation of unique trimetallic Pd-Au-Ag nanocages catalysts with tunable compositions. A series of controlled experiments reveal that the reaction time plays a crucial role in affecting the morphology of the final product. Importantly, the newly-generated Pd-Au-Ag nanocages are high-performance electrocatalysts for the oxidation of both ethylene glycol and glycerol with mass activities of 7578.2 and 5676.1 mA mg -1 , respectively, which are far superior to that of commercial Pd/C. We firmly believe that the strategy and enhanced electrocatalysts developed in this study can be well applied to boost the commercial development of fuel cell technologies.

  18. Self-assembled monolayers of bimetallic Au/Ag nanospheres with superior surface-enhanced Raman scattering activity for ultra-sensitive triphenylmethane dyes detection.

    Science.gov (United States)

    Tian, Yue; Zhang, Hua; Xu, Linlin; Chen, Ming; Chen, Feng

    2018-02-15

    The bimetallic Au/Ag self-assembled monolayers (SAMs) were constructed by using mono-dispersed Au/Ag nanospheres (Ag: 4.07%-34.53%) via evaporation-based assembly strategy. The composition-dependent surface-enhanced Raman scattering (SERS) spectroscopy revealed that the Au/Ag (Ag: 16.83%) SAMs provide maximized activity for triphenylmethane dyes detection. With the inter-metallic synergy, the optimized SAMs enable the Raman intensity of crystal violet molecules to be about 223 times higher than that of monometallic Au SAMs. Moreover, the SERS signals with excellent uniformity (<5% variation) are sensitive down to 10 -13   M concentrations because of the optimal matching between bimetallic plasmon resonance and the incident laser wavelength.

  19. Rattle-type hierarchical particles containing multilevel cores (Ag@AgCl@SiO2 and Au/Ag@AgCl@SiO2) as versatile catalysts.

    Science.gov (United States)

    Huy, Do Xuan; Lee, Ha-Jin; Lee, Young Boo; Choi, Won San

    2014-07-01

    A protocol for the synthesis of rattle-type core@shell particles containing Ag@AgCl or Au/Ag@AgCl core structures was developed, and the use of these particles as catalysts for the decomposition of toxic materials was demonstrated. A monometallic Ag or bimetallic Au/Ag core was incorporated into the interior of SiO2 capsules via controlled heat treatment of metal nanoparticle/SiO2-coated polymer particles, resulting in the formation of rattle-type core@shell structures. By appropriate treatments, it was possible to transform the Ag or Au/Ag core into multilevel cores (Ag@AgCl or Au/Ag@AgCl) within the SiO2 capsules (Ag@AgCl@SiO2 or Au/Ag@AgCl@SiO2). This method for the synthesis of rattle-type core@shell particles is useful for further introducing AgCl fused with plasmonic materials into the capsule structures. The rattle-type core@shell structures were used as photocatalysts for the decomposition of organic pollutants such as methyl orange. Furthermore, these nanocatalysts containing semiconductors such as AgCl were also applied toward the reduction of nitrophenol (NPh) to aminophenol (APh). The Ag@AgCl@SiO2 or Au/Ag@AgCl@SiO2 catalysts showed excellent catalytic properties in the decomposition of toxic substances in terms of their activity and reusability. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Core-shell Au@Pd nanoparticles with enhanced catalytic activity for oxygen reduction reaction via core-shell Au@Ag/Pd constructions

    OpenAIRE

    Chen, Dong; Li, Chengyin; Liu, Hui; Ye, Feng; Yang, Jun

    2015-01-01

    Core-shell nanoparticles often exhibit improved catalytic properties due to the lattice strain created in these core-shell particles. Herein, we demonstrate the synthesis of core-shell Au@Pd nanoparticles from their core-shell Au@Ag/Pd parents. This strategy begins with the preparation of core-shell Au@Ag nanoparticles in an organic solvent. Then, the pure Ag shells are converted into the shells made of Ag/Pd alloy by galvanic replacement reaction between the Ag shells and Pd2+ precursors. Su...

  1. A new class of amorphous cathode active material LixMyPOz (M = Ni, Cu, Co, Mn, Au, Ag, Pd)

    Science.gov (United States)

    Sabi, Yuichi; Sato, Susumu; Hayashi, Saori; Furuya, Tatsuya; Kusanagi, Susumu

    2014-07-01

    A new class of amorphous cathode active material LixMyPOz (LiMPO) is proposed. The materials are sputter deposited to thin film form by Li3PO4 together with metal or metal oxide targets. Among several materials tested as thin-film battery, working material found are M = Ni, Cu, Co, Mn, Au, Ag, Pd. The property is intensively studied for LixCuyPOz (LiCuPO) and LixNiyPOz (LiNiPO). Those materials shows wide composition margin such as composition y between 1 and 3, and high capacity for LiNiPO with maximum value of 330 mAh g-1. The capability to charge and discharge at high rate is shown up to 30 C. This preliminary report reveals its high potentiality for further optimization.

  2. Heavy metals contamination and their risk assessment around the abandoned base metals and Au-Ag mines in Korea

    Science.gov (United States)

    Chon, Hyo-Taek

    2017-04-01

    Heavy metals contamination in the areas of abandoned Au-Ag and base metal mines in Korea was investigated in order to assess the level of metal pollution, and to draw general summaries about the fate of toxic heavy metals in different environments. Efforts have been made to compare the level of heavy metals, chemical forms, and plant uptake of heavy metals in each mine site. In the base-metals mine areas, significant levels of Cd, Cu, Pb and Zn were found in mine dump soils developed over mine waste materials and tailings. Leafy vegetables tend to accumulate heavy metals(in particular, Cd and Zn) higher than other crop plants, and high metal concentrations in rice crops may affect the local residents' health. In the Au-Ag mining areas, arsenic would be the most characteristic contaminant in the nearby environment. Arsenic and heavy metals were found to be mainly associated with sulfide gangue minerals, and the mobility of these metals would be enhanced by the effect of continuing weathering and oxidation. According to the sequential extraction of metals in soils, most heavy metals were identified as non-residual chemical forms, and those are very susceptible to the change of ambient conditions of a nearby environment. The concept of pollution index(PI) of soils gives important information on the extent and degree of multi-element contamination, and can be applied to the evaluation of mine soils before their agricultural use and remediation. The risk assessment process comprising exposure assessment, dose-response assessment, and risk characterization was discussed, and the results of non-cancer risk of As, Cd, and Zn, and those of cancer risk of As were suggested.

  3. Au-Ag Core-Shell Nanospheres for Surface-Enhanced Raman Scattering Detection of Sudan I and Sudan II in Chili Powder

    Directory of Open Access Journals (Sweden)

    Lu Pei

    2015-01-01

    Full Text Available Au-Ag core-shell (Au@Ag bimetallic nanospheres synthesized by a facile seed-growth method are proposed as a substrate for surface-enhanced Raman spectroscopy (SERS to detect azo-group dyes including Sudan I and Sudan II. Au@Ag nanospheres with a series of particle sizes (diameter: 30–120 nm and silver shell thicknesses (6–51 nm were synthesized and compared for their morphological and optical properties to obtain optimum enhancement effect. Normal Raman, SERS, infrared, and ultraviolet-visible were used to investigate the optical absorption properties of Sudan I and Sudan II as well as the enhancement mechanism of Au@Ag substrates. The nanospheres with particle size of 73 ± 6 nm in diameter and silver layer of 27 ± 2 nm resulted in the highest enhancement effect and could be used to detect Sudan I and Sudan II standard solutions at levels as low as 0.4 and 0.1 mg/L, respectively. Moreover, Sudan I and Sudan II in chili powder could be detected at 0.6 and 0.4 mg/kg, respectively. Sudan I and Sudan II with similar structures in complicated food matrices could be distinguished through applying principal component analysis, indicating good selectivity of the SERS method for detection of banned additives in food stuffs at trace levels.

  4. Synthesis of Small Au-Ag Core-Shell Cubes, Cuboctahedra, and Octahedra with Size Tunability and Their Optical and Photothermal Properties.

    Science.gov (United States)

    Chiang, Chieh; Huang, Michael H

    2015-12-02

    Aqueous phase synthesis of small Au-Ag core-shell nanocubes, cuboctahedra, and octahedra is achieved through the deposition of Ag shells on small octahedral Au cores. These nanocrystals show efficient photothermal activity and can assemble into supercrystals. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Phototodynamic activity of zinc monocarboxyphenoxy phthalocyane (ZnMCPPc) conjugated to gold silver (AuAg) nanoparticles in melanoma cancer cells

    Science.gov (United States)

    Manoto, Sello L.; Oluwole, David O.; Malabi, Rudzani; Maphanga, Charles; Ombinda-Lemboumba, Saturnin; Nyokong, Tebello; Mthunzi-Kufa, Patience

    2017-02-01

    Photodynamic therapy (PDT) is a minimally invasive therapeutic modality for the treatment of neoplastic and non-neoplastic diseases. In PDT of cancer, irradiation with light of a specific wavelength leads to activation of a photosensitizer which results in generation of reactive oxygen species (ROS) which induces cell death. Many phthalocyanine photosensitizers are hydrophobic and insoluble in water, which limits their therapeutic efficiency. Consequently, advanced delivery systems and strategies are needed to improve the effectiveness of these photosensitizers. Nanoparticles have shown promising results in increasing aqueous solubility, bioavailability, stability and delivery of photosensitizers to their target. This study investigated the photodynamic activity of zinc monocarboxyphenoxy phthalocyanine (ZnMCPPc) conjugated to gold silver (AuAg) nanoparticles in melanoma cancer cells. The photodynamic activity of ZnMCPPc conjugated to AuAg nanoparticles were evaluated using cellular morphology, viability, proliferation and cytotoxicity. Untreated cells showed no changes in cellular morphology, proliferation and cytotoxicity. However, photoactivated ZnMCPPc conjugated to AuAg nanoparticles showed changes in cell morphology and a dose dependent decrease in cellular viability, proliferation and an increase in cell membrane damage. The ZnMCPPc conjugated to AuAg nanoparticles used in this study was highly effective in inducing cell death of melanoma cancer cells.

  6. Highly sensitive colorimetric detection of glucose in a serum based on DNA-embeded Au@Ag core–shell nanoparticles

    International Nuclear Information System (INIS)

    Kang, Fei; Xu, Kun; Hou, Xiangshu

    2015-01-01

    Glucose is a key energy substance in diverse biology and closely related to the life activities of the organism. To develop a simple and sensitive method for glucose detection is extremely urgent but still remains a key challenge. Herein, we report a colorimetric glucose sensor in a homogeneous system based on DNA-embedded core–shell Au@Ag nanoparticles. In this assay, a glucose substrate was first catalytically oxidized by glucose oxidase to produce H 2 O 2 which would further oxidize and gradually etch the outer silver shell of Au@Ag nanoparticles. Afterwards, the solution color changed from yellow to red and the surface plasmon resonance (SPR) band of Au@Ag nanoparticles declined and red-shifted from 430 to 516 nm. Compared with previous silver-based glucose colorimetric detection strategies, the distinctive SPR band change is superior to the color variation, which is critical to the high sensitivity of this assay. Benefiting from the outstanding optical property, robust stability and well-dispersion of the core–shell Au@AgNPs hybrid, this colorimetric assay obtained a detection limit of glucose as low as 10 nM, which is at least a 10-fold improvement over other AgNPs-based procedures. Moreover, this optical biosensor was successfully employed to the determination of glucose in fetal bovine serum. (paper)

  7. Site-Selective Carving and Co-Deposition: Transformation of Ag Nanocubes into Concave Nanocrystals Encased by Au-Ag Alloy Frames.

    Science.gov (United States)

    Ahn, Jaewan; Wang, Daniel; Ding, Yong; Zhang, Jiawei; Qin, Dong

    2018-01-23

    We report a facile synthesis of Ag nanocubes with concave side faces and Au-Ag alloy frames, namely Ag@Au-Ag concave nanocrystals, by titrating HAuCl 4 solution into an aqueous mixture of Ag nanocubes, ascorbic acid (H 2 Asc), NaOH, and cetyltrimethylammonium chloride (CTAC) at an initial pH of 11.6 under ambient conditions. Different from all previous studies involving poly(vinylpyrrolidine), the use of CTAC at a sufficiently high concentration plays an essential role in carving away Ag atoms from the side faces through galvanic replacement. Concurrent co-deposition of Au and Ag atoms via chemical reduction at orthogonal sites on the surface of Ag nanocubes leads to the generation of Ag@Au-Ag concave nanocrystals with well-defined and controllable structures. Specifically, in the presence of CTAC-derived Cl - ions, the titrated HAuCl 4 is maintained in the AuCl 4 - species, enabling its galvanic replacement with the Ag atoms located on the side faces of nanocubes. The released Ag + ions can be retained in the soluble form of AgCl 2 - by complexing with the Cl - ions. Both the AuCl 4 - and AgCl 2 - in the solution are then reduced by ascorbate monoanion, a product of the neutralization reaction between H 2 Asc and NaOH, to Au and Ag atoms for their preferential co-deposition onto the edges and corners of the Ag nanocubes. Compared with Ag nanocubes, the Ag@Au-Ag concave nanocrystals exhibit much stronger SERS activity at an excitation of 785 nm, making it feasible to monitor the Au-catalyzed reduction of 4-nitrothiophenol by NaBH 4 in situ. When the Ag cores are removed, the concave nanocrystals evolve into Au-Ag nanoframes with controllable ridge thicknesses.

  8. Induced polarization imaging applied to exploration for low-sulfidation epithermal Au-Ag deposits, Seongsan mineralized district, South Korea

    Science.gov (United States)

    Han, Man-Ho; Shin, Seung Wook; Park, Samgyu; Cho, Seong-Jun; Kim, Jung-Ho

    2016-10-01

    The determination of mineralization boundaries during mineral exploration for undiscovered low-sulfidation epithermal Au-Ag deposits is a significant challenge because of the extensive survey areas required. Induced polarization (IP) imaging is an effective geophysical technique for the detection of sulfides or clay. Thus, this method is considered useful to determine the boundaries of subsurface mineralization and hydrothermal alteration associated with epithermal deposits. We used 2D and 3D IP imaging to define the silicification and mineralization boundaries of the Moisan deposit in the Seongsan mineralized district, which is geologically well-known. The boundaries of the silicification zone were defined by high resistivity values of 600 Ω-m, and those of the mineralization zone were defined by high global chargeability values of 3 mV V-1. The continuity of the high resistivity anomaly corresponded well to the silicification (quartz veins) exposed in outcrop. In addition, it is geologically reasonable that the chargeability anomaly, ⩾3 mV V-1, associated with the mineralization/hydrothermal alteration zone was concentrated at near-surface depths, and extensively surrounding the resistivity anomaly, ⩾600 Ω-m, associated with the silicification zone.

  9. Structure reactivity relationships during N2O hydrogenation over Au-Ag alloys: A study by field emission techniques

    Science.gov (United States)

    Jacobs, Luc; Barroo, Cédric; Gilis, Natalia; Lambeets, Sten V.; Genty, Eric; Visart de Bocarmé, Thierry

    2018-03-01

    To make available atomic oxygen at the surface of a catalyst is the key step for oxidation reactions on Au-based catalysts. In this context, Au-Ag alloys catalysts exhibit promising properties for selective oxidation reactions of alcohols: low temperature activity and high selectivity. The presence of O(ads) and its effects on the catalytic reactivity is studied via the N2O dissociative adsorption and subsequent hydrogenation. Field emission techniques are particularly suited to study this reaction: Field Ion Microscopy (FIM) and Field Emission Microscopy (FEM) enable to image the extremity of sharp metallic tips, the size and morphology of which are close to those of one single catalytic particle. The reaction dynamics is studied in the 300-320 K temperature range and at a pressure of 3.5 × 10-3 Pa. The main results are a strong structure/reactivity relationship during N2O + H2 reaction over Au-8.8 at.%Ag model catalysts. Comparison of high-resolution FIM images of the clean sample and FEM images during reaction shows a sensitivity of the reaction to the local structure of the facets, independently of the used partial pressures of both N2O and H2. This suggests a localised dissociative adsorption step for N2O and H2 with the formation of a reactive interface around the {210} facets.

  10. Effect of Spin Multiplicity in O2 Adsorption and Dissociation on Small Bimetallic AuAg Clusters.

    Science.gov (United States)

    García-Cruz, Raúl; Poulain, Enrique; Hernández-Pérez, Isaías; Reyes-Nava, Juan A; González-Torres, Julio C; Rubio-Ponce, A; Olvera-Neria, Oscar

    2017-08-17

    To dispose of atomic oxygen, it is necessary the O 2 activation; however, an energy barrier must be overcome to break the O-O bond. This work presents theoretical calculations of the O 2 adsorption and dissociation on small pure Au n and Ag m and bimetallic Au n Ag m (n + m ≤ 6) clusters using the density functional theory (DFT) and the zeroth-order regular approximation (ZORA) to explicitly include scalar relativistic effects. The most stable Au n Ag m clusters contain a higher concentration of Au with Ag atoms located in the center of the cluster. The O 2 adsorption energy on pure and bimetallic clusters and the ensuing geometries depend on the spin multiplicity of the system. For a doublet multiplicity, O 2 is adsorbed in a bridge configuration, whereas for a triplet only one O-metal bond is formed. The charge transfer from metal toward O 2 occupies the σ* O-O antibonding natural bond orbital, which weakens the oxygen bond. The Au 3 ( 2 A) cluster presents the lowest activation energy to dissociate O 2 , whereas the opposite applies to the AuAg ( 3 A) system. In the O 2 activation, bimetallic clusters are not as active as pure Au n clusters due to the charge donated by Ag atoms being shared between O 2 and Au atoms.

  11. [UV-Vis studies on the course of reaction of Au/Ag alloy colloid with hydrogen tetrachloroaurate(III) hydrate].

    Science.gov (United States)

    Jin, Yi-Liang; Yao, Jian-Lin; Gu, Ren-Ao

    2009-10-01

    Using citrate as protector, Au-Ag alloy nanoparticles with different molar ratios were prepared with hydrazine as the reducer. One plasmon band between monometallic Ag and Au was observed in their UV-Vis spectra. And the peak of alloy shifted linearly with the ratio of Au changing in the alloy. By UV-Vis spectra, the course of reaction of the alloy colloid with HAuCl4 was studied. The result shows that the UV-Vis spectra of the alloy colloid changed regularly with the adding volume of HAuCl4 increasing. And there is a linear interval in it with the change in the calculated ratio of Au. With the former studies, the course can be attributed to the dealloy of Au/Ag alloy.

  12. Identification of Volatile Biomarkers of Gastric Cancer Cells and Ultrasensitive Electrochemical Detection based on Sensing Interface of Au-Ag Alloy coated MWCNTs

    OpenAIRE

    Zhang, Yixia; Gao, Guo; Liu, Huijuan; Fu, Hualin; Fan, Jun; Wang, Kan; Chen, Yunsheng; Li, Baojie; Zhang, Chunlei; Zhi, Xiao; He, Lin; Cui, Daxiang

    2014-01-01

    Successful development of novel electrochemical biosensing interface for ultrasensitive detection of volatile biomarkers of gastric cancer cells is a challenging task. Herein we reported to screen out novel volatile biomarkers associated with gastric cancer cells and develop a novel Au-Ag alloy composites-coated MWCNTs as sensing interface for ultrasensitive detection of volatile biomarkers. MGC-803 gastric cancer cells and GES-1 gastric mucous cells were cultured in serum-free media. The sam...

  13. [Radiographic evaluation of 12% Au-Ag-Pd alloy cast lower denture plates constructed by dental student as a laboratory exercise].

    Science.gov (United States)

    Miyao, M; Yamauchi, M; Sakai, M; Nishizawa, M; Shimizu, M; Kawano, J

    1990-12-01

    We evaluated 12% Au-Ag-Pd alloy cast lower denture plates prepared by dental students in laboratory exercises for casting defects. First, we determined the most suitable exposure conditions for nondestructive radiographic test of 12% Au-Ag-Pd alloy. Subsequently, 130 plates were nondestructively evaluated by radiography under the most suitable exposure conditions. In radiographic testing using X-Omat RP films (Eastman Kodak Co.) and X-Omatic Fine Screen (Eastman Kodak Co.), the most suitable exposure conditions involved a target-to-film distance of 1.9 m, tube voltage of 148 Kvp, tube current of 10 mA, and exposure time of 1.5 sec. Preliminary radiographic examination of artificial casting defects revealed semispherical defects in the diameter of 0.25 mm in 1.6 mm-thick 12% Au-Ag-Pd alloy plates and detects of 0.26 mm in 2.4 mm thick plates. In the 130 cast plates, 56 casting defects were detected. These defects were found at the left webbing part in 40 (30.8%), right webbing part in 36 (27.7%), lingual bar in 7 (5.4%), I-bar in 4 (3.0%), and at other regions of the metal frames in 3 (2.3%) cases. These results indicate that nondestructive radiographic testing is as effective in detection of casting defects in 12% Au-Ag-Pd alloy cast plates as it is in Co-Cr and Ni-Cr alloy plates. This method was also found to be effective in evaluation of the practice metal frames constructed by dental students.

  14. Green synthesis, characterization of Au-Ag core-shell nanoparticles using gripe water and their applications in nonlinear optics and surface enhanced Raman studies

    Science.gov (United States)

    Kirubha, E.; Palanisamy, P. K.

    2014-12-01

    In recent years there has been excessive progress in the ‘green’ chemistry approach for the synthesis of gold and silver nanoparticles. Bimetallic nanoparticles have gained special significance due to their unique tunable optical properties. Herein we report a facile one-pot, eco-friendly synthesis of Au-Ag bimetallic core-shell nanoparticles using gripe water as reducing as well as stabilizing agent. The as-synthesized Au-Ag nanoparticles are characterized using UV-Vis spectroscopy to determine the surface plasmon resonance, and using transmission electron microscopy to study the morphology and the particle size. The optical nonlinearity of the bimetallic nanoparticles investigated by z-scan technique using femtosecond Ti:sapphire is in the order of 109. The nonlinear optical parameters such as the nonlinear refractive index n2, nonlinear absorption coefficient β and the third order nonlinear susceptibility χ3 are measured for various wavelengths from 700 nm to 950 nm. The Au-Ag nanoparticles are also used in surface enhanced Raman spectroscopic studies to enhance the Raman signals of rhodamine 6G.

  15. Computational investigation of CO adsorbed on Aux, Agx and (AuAg)x nanoclusters (x = 1 - 5, 147) and monometallic Au and Ag low-energy surfaces*

    Science.gov (United States)

    Gould, Anna L.; Catlow, C. Richard A.; Logsdail, Andrew J.

    2018-02-01

    Density functional theory calculations have been performed to investigate the use of CO as a probe molecule for the determination of the structure and composition of Au, Ag and AuAg nanoparticles. For very small nanoclusters (x = 1 - 5), the CO vibrational frequencies can be directly correlated to CO adsorption strength, whereas larger 147-atom nanoparticles show a strong energetic preference for CO adsorption at a vertex position but the highest wavenumbers are for the bridge positions. We also studied CO adsorption on Au and Ag (100) and (111) surfaces, for a 1 monolayer coverage, which proves to be energetically favourable on atop only and bridge positions for Au (100) and atop for Ag (100); vibrational frequencies of the CO molecules red-shift to lower wavenumbers as a result of increased metal coordination. We conclude that CO vibrational frequencies cannot be solely relied upon in order to obtain accurate compositional analysis, but we do propose that elemental rearrangement in the core@shell nanoclusters, from Ag@Au (or Au@Ag) to an alloy, would result in a shift in the CO vibrational frequencies that indicate changes in the surface composition. Contribution to the Topical Issue "Shaping Nanocatalysts", edited by Francesca Baletto, Roy L. Johnston, Jochen Blumberger and Alex Shluger.Supplementary material in the form of one pdf file available from the Journal web page at http://https://doi.org/10.1140/epjb/e2017-80280-7

  16. Core-shell Au@Pd nanoparticles with enhanced catalytic activity for oxygen reduction reaction via core-shell Au@Ag/Pd constructions

    Science.gov (United States)

    Chen, Dong; Li, Chengyin; Liu, Hui; Ye, Feng; Yang, Jun

    2015-01-01

    Core-shell nanoparticles often exhibit improved catalytic properties due to the lattice strain created in these core-shell particles. Herein, we demonstrate the synthesis of core-shell Au@Pd nanoparticles from their core-shell Au@Ag/Pd parents. This strategy begins with the preparation of core-shell Au@Ag nanoparticles in an organic solvent. Then, the pure Ag shells are converted into the shells made of Ag/Pd alloy by galvanic replacement reaction between the Ag shells and Pd2+ precursors. Subsequently, the Ag component is removed from the alloy shell using saturated NaCl solution to form core-shell Au@Pd nanoparticles with an Au core and a Pd shell. In comparison with the core-shell Au@Pd nanoparticles upon directly depositing Pd shell on the Au seeds and commercial Pd/C catalysts, the core-shell Au@Pd nanoparticles via their core-shell Au@Ag/Pd templates display superior activity and durability in catalyzing oxygen reduction reaction, mainly due to the larger lattice tensile effect in Pd shell induced by the Au core and Ag removal. PMID:26144550

  17. Core-shell Au@Pd nanoparticles with enhanced catalytic activity for oxygen reduction reaction via core-shell Au@Ag/Pd constructions

    Science.gov (United States)

    Chen, Dong; Li, Chengyin; Liu, Hui; Ye, Feng; Yang, Jun

    2015-07-01

    Core-shell nanoparticles often exhibit improved catalytic properties due to the lattice strain created in these core-shell particles. Herein, we demonstrate the synthesis of core-shell Au@Pd nanoparticles from their core-shell Au@Ag/Pd parents. This strategy begins with the preparation of core-shell Au@Ag nanoparticles in an organic solvent. Then, the pure Ag shells are converted into the shells made of Ag/Pd alloy by galvanic replacement reaction between the Ag shells and Pd2+ precursors. Subsequently, the Ag component is removed from the alloy shell using saturated NaCl solution to form core-shell Au@Pd nanoparticles with an Au core and a Pd shell. In comparison with the core-shell Au@Pd nanoparticles upon directly depositing Pd shell on the Au seeds and commercial Pd/C catalysts, the core-shell Au@Pd nanoparticles via their core-shell Au@Ag/Pd templates display superior activity and durability in catalyzing oxygen reduction reaction, mainly due to the larger lattice tensile effect in Pd shell induced by the Au core and Ag removal.

  18. Cube-like Fe3O4@SiO2@Au@Ag magnetic nanoparticles: a highly efficient SERS substrate for pesticide detection

    Science.gov (United States)

    Sun, Mei; Zhao, Aiwu; Wang, Dapeng; Wang, Jin; Chen, Ping; Sun, Henghui

    2018-04-01

    As a novel surface-enhanced Raman spectroscopic (SERS) nanocomposite, cube-like Fe3O4@SiO2@Au@Ag magnetic nanoparticles (NPs) were synthesized for the first time. Cube-like α-Fe2O3 NPs with uniform size were achieved by optimizing reaction temperature and time. Firstly, the cube-like Fe3O4@SiO2 with good dispersity was achieved by calcining α-Fe2O3@SiO2 NPs in hydrogen atmosphere at 360 °C for 2.5 h, followed by self-assembling a PEI shell via sonication. Furthermore, the Au@Ag particles were densely assembled on the Fe3O4@SiO2 NPs to form the Fe3O4@SiO2@Au@Ag composite structure via strong Ag-N interaction. The obtained nanocomposites exhibited an excellent SERS behavior, reflected by the low detection of limit (p-ATP) at the 5 × 10-14 M level. Moreover, these nanocubes were used for the detection of thiram, and the detection limit can reach 5 × 10-11 M. Meanwhile, the U.S. Environmental Protection Agency specifies that the residue in fruit must be lower than 7 ppm. Hence, the resulting substrate with high SERS activity has great practical potential applications in the rapid detection of chemical, biological, and environment pollutants with a simple portable Raman instrument at trace level.

  19. Effect of the Fabrication Parameters of the Nanosphere Lithography Method on the Properties of the Deposited Au-Ag Nanoparticle Arrays

    Directory of Open Access Journals (Sweden)

    Jing Liu

    2017-04-01

    Full Text Available The nanosphere lithography (NSL method can be developed to deposit the Au-Ag triangle hexagonal nanoparticle arrays for the generation of localized surface plasmon resonance. Previously, we have found that the parameters used to form the NSL masks and the physical methods required to deposit the Au-Ag thin films had large effects on the geometry properties of the nanoparticle arrays. Considering this, the different parameters used to grow the Au-Ag triangle hexagonal nanoparticle arrays were investigated. A single‐layer NSL mask was formed by using self‐assembly nano-scale polystyrene (PS nanospheres with an average radius of 265 nm. At first, the concentration of the nano-scale PS nanospheres in the solution was set at 6 wt %. Two coating methods, drop-coating and spin-coating, were used to coat the nano-scale PS nanospheres as a single‐layer NSL mask. From the observations of scanning electronic microscopy (SEM, we found that the matrixes of the PS nanosphere masks fabricated by using the drop-coating method were more uniform and exhibited a smaller gap than those fabricated by the spin-coating method. Next, the drop-coating method was used to form the single‐layer NSL mask and the concentration of nano-scale PS nanospheres in a solution that was changed from 4 to 10 wt %, for further study. The SEM images showed that when the concentrations of PS nanospheres in the solution were 6 and 8 wt %, the matrixes of the PS nanosphere masks were more uniform than those of 4 and 10 wt %. The effects of the one-side lifting angle of substrates and the vaporization temperature for the solvent of one-layer self-assembly PS nanosphere thin films, were also investigated. Finally, the concentration of the nano-scale PS nanospheres in the solution was set at 8 wt % to form the PS nanosphere masks by the drop-coating method. Three different physical deposition methods, including thermal evaporation, radio-frequency magnetron sputtering, and e

  20. The effect of local dielectric environment on the resonance light scattering of Au-Ag bimetallic nanotube

    Science.gov (United States)

    Zhao, Shu-min; Zhu, Jian

    2017-12-01

    In this study, electrodynamic calculations were used to investigate the resonance light-scattering (RLS) properties of dielectric-Au-Ag double nanotube. It has been found that the scattering spectrum exhibits at most three pronounced RLS peaks in the visible region, and the RLS band number could be fine tuned by changing the dielectric constant of the inner dielectric wire. The outer dielectric surrounding also greatly affects the intensity and wavelength position of the RLS. The RLS with the longest wavelength (denoted as peak3) is always enhanced with the increase of the outer surrounding dielectric constant, i.e., ɛ 4. Whereas the ɛ 4-dependent scattering intensity change of RLS at middle wavelength becomes non-monotonous when the Ag-coating thickness is much smaller than that of Au wall. On the contrary, the ɛ 4-dependent scattering intensity change of RLS at shorter wavelength becomes non-monotonous when the Ag-coating thickness is much larger than that of Au wall. Although peak3 has a longer wavelength when the inner wire dielectric constant ɛ 1 has a large value, the ɛ 4-dependent wavelength shift has been decreased; as the wavelength shift has been decreased, ɛ 1 is increased. Similarly, although peak3 has a longer wavelength when the Ag coating has a small thickness, the ɛ 4-dependent wavelength shift has been decreased as the Ag-coating thickness is decreased. These calculating results about local dielectric environment-dependent RLS present a potential for design and fabrication of optical refractive index nanosensors based on light scattering.

  1. Influence of fabrication procedure on the electrochemical performance of Ag/AgCl reference electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Stoica, Daniela [Department of Biomedical and Inorganic Chemistry, Laboratoire National de Metrologie et d' Essais, 1 Rue Gaston Boissier, 75015 Paris (France); Brewer, Paul J., E-mail: paul.brewer@npl.co.uk [Analytical Science Division, National Physical Laboratory, Teddington, Middlesex TW11 0LW (United Kingdom); Brown, Richard J.C. [Analytical Science Division, National Physical Laboratory, Teddington, Middlesex TW11 0LW (United Kingdom); Fisicaro, Paola [Department of Biomedical and Inorganic Chemistry, Laboratoire National de Metrologie et d' Essais, 1 Rue Gaston Boissier, 75015 Paris (France)

    2011-11-30

    The influence of several parameters in the preparation procedure of thermal-electrolytic Ag/AgCl electrodes on the resulting electrode performance has been studied. In particular, we report the effect on electrode performance of subtle variations in the preparation of silver oxide paste used for electrode manufacture, in thermal annealing conditions employed and in the procedure for electrochemically converting a fraction of the electrode from silver to silver chloride. Scanning electron microscopy and electrochemical impedance spectroscopy have been used to study the characteristics of the electrodes produced. This work reveals a correlation between the electrochemical behaviour and surface physical characteristics - in particular electrode porosity. The outputs of this study have positive implications for improving the accuracy and comparability of primary pH measurement.

  2. The influence of cochlear implant electrode position on performance

    NARCIS (Netherlands)

    Marel, K.S. van der; Briaire, J.J.; Verbist, B.M.; Muurling, T.J.; Frijns, J.H.M.

    2015-01-01

    To study the relation between variables related to cochlear implant electrode position and speech perception performance scores in a large patient population.The study sample consisted of 203 patients implanted with a CII or HiRes90K implant with a HiFocus 1 or 1J electrode of Advanced Bionics.

  3. Investigations on the influence of pressure, current and electrode gap in high-pressure mercury lamps

    International Nuclear Information System (INIS)

    Flesch, P; Neiger, M

    2005-01-01

    This paper is concerned with the numerical simulation of high-intensity discharge lamps, focusing on the influence of pressure, current and electrode gap on plasma, anode and cathode properties. The interaction between electrodes and plasma is taken into account. Comparisons between experimental findings and numerical results show that the observed increase in the total lamp voltage caused by an increasing lamp current is a superposition of an increasing lamp voltage due to an increasing pressure (caused by the increasing lamp current) and a decreasing lamp voltage due to the increasing lamp current (if the pressure would be constant). Furthermore, the numerical results reveal that the plasma potential in the whole plasma strongly depends on the electrode gap and that even the electrode temperature and the arc attachment to the electrodes are influenced by the size of the electrode gap

  4. Binding Affinity of a Highly Sensitive Au/Ag/Au/Chitosan-Graphene Oxide Sensor Based on Direct Detection of Pb2+ and Hg2+ Ions

    Directory of Open Access Journals (Sweden)

    Nur Hasiba Kamaruddin

    2017-10-01

    Full Text Available The study of binding affinity is essential in surface plasmon resonance (SPR sensing because it allows researchers to quantify the affinity between the analyte and immobilised ligands of an SPR sensor. In this study, we demonstrate the derivation of the binding affinity constant, K, for Pb2+ and Hg2+ ions according to their SPR response using a gold/silver/gold/chitosan–graphene oxide (Au/Ag/Au/CS–GO sensor for the concentration range of 0.1–5 ppm. The higher affinity of Pb2+ to binding with the CS–GO sensor explains the outstanding sensitivity of 2.05 °ppm−1 against 1.66 °ppm−1 of Hg2+. The maximum signal-to-noise ratio (SNR upon detection of Pb2+ is 1.53, and exceeds the suggested logical criterion of an SNR. The Au/Ag/Au/CS–GO SPR sensor also exhibits excellent repeatability in Pb2+ due to the strong bond between its functional groups and this cation. The adsorption data of Pb2+ and Hg2+ on the CS–GO sensor fits well with the Langmuir isotherm model where the affinity constant, K, of Pb2+ and Hg2+ ions is computed. The affinity of Pb2+ ions to the Au/Ag/Au/CS–GO sensor is significantly higher than that of Hg2+ based on the value of K, 7 × 105 M−1 and 4 × 105 M−1, respectively. The higher shift in SPR angles due to Pb2+ and Hg2+ compared to Cr3+, Cu2+ and Zn2+ ions also reveals the greater affinity of the CS–GO SPR sensor to them, thus supporting the rationale for obtaining K for these two heavy metals. This study provides a better understanding on the sensing performance of such sensors in detecting heavy metal ions.

  5. Au@Ag/Au nanoparticles assembled with activatable aptamer probes as smart ``nano-doctors'' for image-guided cancer thermotherapy

    Science.gov (United States)

    Shi, Hui; Ye, Xiaosheng; He, Xiaoxiao; Wang, Kemin; Cui, Wensi; He, Dinggeng; Li, Duo; Jia, Xuekun

    2014-07-01

    Although nanomaterial-based theranostics have increased positive expectations from cancer treatment, it remains challenging to develop in vivo ``nano-doctors'' that provide high-contrast image-guided site-specific therapy. Here we designed an activatable theranostic nanoprobe (ATNP) via self-assembly of activatable aptamer probes (AAPs) on Au@Ag/Au nanoparticles (NPs). As both quenchers and heaters, novel Au@Ag/Au NPs were prepared, showing excellent fluorescence quenching and more effective near-infrared photothermal therapy than Au nanorods. The AAP comprised a thiolated aptamer and a fluorophore-labeled complementary DNA; thus, the ATNP with quenched fluorescence in the free state could realize signal activation through target binding-induced conformational change of the AAP, and then achieve on-demand treatment under image-guided irradiation. By using S6 aptamer as the model, in vitro and in vivo studies of A549 lung cancer verified that the ATNP greatly improved imaging contrast and specific destruction, suggesting a robust and versatile theranostic strategy for personalized medicine in future.Although nanomaterial-based theranostics have increased positive expectations from cancer treatment, it remains challenging to develop in vivo ``nano-doctors'' that provide high-contrast image-guided site-specific therapy. Here we designed an activatable theranostic nanoprobe (ATNP) via self-assembly of activatable aptamer probes (AAPs) on Au@Ag/Au nanoparticles (NPs). As both quenchers and heaters, novel Au@Ag/Au NPs were prepared, showing excellent fluorescence quenching and more effective near-infrared photothermal therapy than Au nanorods. The AAP comprised a thiolated aptamer and a fluorophore-labeled complementary DNA; thus, the ATNP with quenched fluorescence in the free state could realize signal activation through target binding-induced conformational change of the AAP, and then achieve on-demand treatment under image-guided irradiation. By using S6 aptamer as

  6. Influence of Electric Fields on Biofouling of Carbonaceous Electrodes.

    Science.gov (United States)

    Pandit, Soumya; Shanbhag, Sneha; Mauter, Meagan; Oren, Yoram; Herzberg, Moshe

    2017-09-05

    Biofouling commonly occurs on carbonaceous capacitive deionization electrodes in the process of treating natural waters. Although previous work reported the effect of electric fields on bacterial mortality for a variety of medical and engineered applications, the effect of electrode surface properties and the magnitude and polarity of applied electric fields on biofilm development has not been comprehensively investigated. This paper studies the formation of a Pseudomonas aeruginosa biofilm on a Papyex graphite (PA) and a carbon aerogel (CA) in the presence and the absence of an electric field. The experiments were conducted using a two-electrode flow cell with a voltage window of ±0.9 V. The CA was less susceptible to biofilm formation compared to the PA due to its lower surface roughness, lower hydrophobicity, and significant antimicrobial properties. For both positive and negative applied potentials, we observed an inverse relationship between biofilm formation and the magnitude of the applied potential. The effect is particularly strong for the CA electrodes and may be a result of cumulative effects between material toxicity and the stress experienced by cells at high applied potentials. Under the applied potentials for both electrodes, high production of endogenous reactive oxygen species (ROS) was indicative of bacterial stress. For both electrodes, the elevated specific ROS activity was lowest for the open circuit potential condition, elevated when cathodically and anodically polarized, and highest for the ±0.9 V cases. These high applied potentials are believed to affect the redox potential across the cell membrane and disrupt redox homeostasis, thereby inhibiting bacterial growth.

  7. Diffusion of single Au, Ag and Cu atoms inside Si(111)-(7 × 7) half unit cells: A comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Qin [Department of Physics, Southern University of Science and Technology, Shenzhen, Guangdong 518055 (China); Department of Physics, The Chinese University of Hong Kong, Shatin, New Territory, Hong Kong (China); Science and Technology on Surface Physics and Chemistry Laboratory, Mianyang, Sichuan 621908 (China); Fu, Qiang [Institut für Physik and IRIS Adlershof, Humboldt-Universität zu Berlin, Zum Großen Windkanal 6, 12489 Berlin (Germany); Shao, Xiji; Ma, Xuhang; Wu, Xuefeng [Department of Physics, Southern University of Science and Technology, Shenzhen, Guangdong 518055 (China); Wang, Kedong, E-mail: wangkd@sustc.edu.cn [Department of Physics, Southern University of Science and Technology, Shenzhen, Guangdong 518055 (China); Xiao, Xudong, E-mail: xdxiao@phy.cuhk.edu.hk [Department of Physics, The Chinese University of Hong Kong, Shatin, New Territory, Hong Kong (China)

    2017-04-15

    Highlights: • Diffusions of Au, Ag and Cu atoms in the half unit cells of Si(111)-(7×7) have been studied by using a STM-based I-t method. • Despite their similar absorption sites, the diffusion dynamics show obvious differences between Ag and the other two. • Theoretical calculations suggest that different potential energy profiles are responsible for the observed differences. - Abstract: The diffusion behaviors of single Au, Ag and Cu atoms on Si(111)-(7 × 7) half unit cells have been investigated via combining scanning tunneling microscopy and first-principles calculations. Despite the similar adsorption sites between both half unit cells among these elements, the diffusion dynamics show obvious differences between Ag and the other two. Although obvious asymmetry has been found in the diffusion behaviors of Au and Cu atoms in two half unit cells of Si(111)-(7 × 7), the asymmetry behaves in a way different from that of Ag atoms and no dual-time character has been observed for the diffusions of Au and Cu in both half unit cells. Theoretical calculations suggest a different potential energy profile caused by the stronger hybridization between d states of Au (Cu) and Si states make the concept of basin useless for the diffusion of Au and Cu atoms inside the half unit cells of Si(111)-(7 × 7).

  8. The Nature of the Binding of Au, Ag, and Pd to Benzene, Coronene, and Graphene: From Benchmark CCSD(T) Calculations to Plane-Wave DFT Calculations

    Science.gov (United States)

    2011-01-01

    The adsorption of Ag, Au, and Pd atoms on benzene, coronene, and graphene has been studied using post Hartree–Fock wave function theory (CCSD(T), MP2) and density functional theory (M06-2X, DFT-D3, PBE, vdW-DF) methods. The CCSD(T) benchmark binding energies for benzene–M (M = Pd, Au, Ag) complexes are 19.7, 4.2, and 2.3 kcal/mol, respectively. We found that the nature of binding of the three metals is different: While silver binds predominantly through dispersion interactions, the binding of palladium has a covalent character, and the binding of gold involves a subtle combination of charge transfer and dispersion interactions as well as relativistic effects. We demonstrate that the CCSD(T) benchmark binding energies for benzene–M complexes can be reproduced in plane-wave density functional theory calculations by including a fraction of the exact exchange and a nonempirical van der Waals correction (EE+vdW). Applying the EE+vdW method, we obtained binding energies for the graphene–M (M = Pd, Au, Ag) complexes of 17.4, 5.6, and 4.3 kcal/mol, respectively. The trends in binding energies found for the benzene–M complexes correspond to those in coronene and graphene complexes. DFT methods that use empirical corrections to account for the effects of vdW interactions significantly overestimate binding energies in some of the studied systems. PMID:22076121

  9. Research on the influence of ac current overflowing on grounding electrode corrosion

    Science.gov (United States)

    Liu, Guohua; Wu, Zhen; Li, Wei; Zhang, Zhanlong; Mei, Daojun

    2017-09-01

    In the power system, earth electrode is laid in the soil for current overflowing, to ensure secure and stable operation of power grid and electric accessory. Compared with general pipeline laid in the soil, earth electrode is under the circumstance of unbalanced grounding current of neutral point and electric field induced by high-voltage transmission line, so there is current straightly overflowing from electrode surface to the earth. Grounding current density carried by earth electrode is large, with an important effect on electrochemical corrosion of earth electrode in the soil. Based on the established corrosion model, this paper makes research on the influence of AC current overflowing on corrosion potential, current and deformation, without considering the effect of species diffusion. What is more, the relationship between the amount of corrosion deformation and the frequency of ground current is also studied.

  10. Identification of volatile biomarkers of gastric cancer cells and ultrasensitive electrochemical detection based on sensing interface of Au-Ag alloy coated MWCNTs.

    Science.gov (United States)

    Zhang, Yixia; Gao, Guo; Liu, Huijuan; Fu, Hualin; Fan, Jun; Wang, Kan; Chen, Yunsheng; Li, Baojie; Zhang, Chunlei; Zhi, Xiao; He, Lin; Cui, Daxiang

    2014-01-01

    Successful development of novel electrochemical biosensing interface for ultrasensitive detection of volatile biomarkers of gastric cancer cells is a challenging task. Herein we reported to screen out novel volatile biomarkers associated with gastric cancer cells and develop a novel Au-Ag alloy composites-coated MWCNTs as sensing interface for ultrasensitive detection of volatile biomarkers. MGC-803 gastric cancer cells and GES-1 gastric mucous cells were cultured in serum-free media. The sample preparation approaches and HS-SPME conditions were optimized for screening volatile biomarkers. Volatiles emitted from the headspace of the cells/medium culture were identified using GC-MS. The Au-Ag nanoparticles-coated multiwalled carbon nanotubes were prepared as a sensing interface for detection of volatile biomarkers. Results showed that eight different volatile metabolites were screened out between MGC-803 cells and GES-1 cells. Two compounds such as 3-octanone and butanone were specifically present in the headspace of the MGC-803 cells. Three volatiles such as 4-isopropoxybutanol, nonanol and 4-butoxy 1-butanol coexisted in the headspace of both the MGC-803 cells and the GES-1 cells, their concentrations in the headspace of the GES-1cells were markedly higher than those in the MGC-803 cells, three volatiles such as formic acid propyl ester, 1.4-butanediol and 2, 6, 11-trimethyl dodecane solely existed in the headspace of the GES-1 cells. The nanocomposites of MWNTs loaded with Au-Ag nanoparticles were prepared as a electrochemical sensing interface for detection of two volatile biomarkers, cyclic voltammetry studies showed that the fabricated sensor could detect 3-octanone in the range of 0~0.0025% (v/v) and with a detection limitation of 0.3 ppb, could detect butanone in the range of 0 ~ 0.055% (v/v), and with a detection limitation of 0.5 ppb, and exhibited good selectivity. The novel electrochemical biosensor combined with volatile biomarkers of gastric cancer

  11. Plavica epithermal Au-Ag-Cu deposit in eastern Macedonia: Geology and 3D model of valuable component distribution in ore

    Science.gov (United States)

    Serafimovski, T.; Volkov, A. V.; Serafimovski, D.; Tasev, G.; Ivanovski, I.; Murashov, K. Yu.

    2017-07-01

    The Plavica Au-Ag-Cu deposit is related to the large Neogene volcanic center, which complicates the paleocaldera in the central Kratovo-Zletovo ore district of eastern Macedonia. Based on the geology, ore mineralogy, wall-rock alteration, and fluid inclusions, the Plavica deposit has been referred to the epithermal high-sulfidation type. The general 3D model of orebody at this deposit is based on its general geological structure and complex distribution of metal contents. The framework of the 3D model, which has been constructed in the ArcGIS System, comprises 195 exploration boreholes 47295.8 m in total length. The 3D model allows to a better understanding of distribution of mineralization and supplements the geological data on the deposit.

  12. DISLOCATIONS MOBILITY UNDER THE IMAGE FORCE EFFECT IN BICRYSTALS OF CFC MATERIALS: CU-X, X = PB, AL, AU, AG AND NI

    Directory of Open Access Journals (Sweden)

    A OUCHTATI

    2015-06-01

    Full Text Available The image force undergone by a matrix dislocations close and parallel to an interphase boundary is studied in Cu-X bicrystals (with X = Pb, Al, Au, Ag, Ni for disorientations ranging between 0° and 90°.  Dislocations have a Burgers vector  = a/2 [110]. The elastic energy of dislocation-boundary interaction is calculated within the framework of anisotropic linear elasticity. The elastic energy is related to the difference of the two metals shear moduli. It is about a few hundred pico Joule per meter. The image force can be repulsive or attractive according to the sign and the intensity of shear moduli difference. The isoenergy maps have various symmetries according to the disorientation.

  13. Autoclave mediated one-pot-one-minute synthesis of AgNPs and Au-Ag nanocomposite from Melia azedarach bark extract with antimicrobial activity against food pathogens.

    Science.gov (United States)

    Pani, Alok; Lee, Joong Hee; Yun, Soon-Ii

    2016-01-01

    The increasing use of nanoparticles and nanocomposite in pharmaceutical and processed food industry have increased the demand for nontoxic and inert metallic nanostructures. Chemical and physical method of synthesis of nanostructures is most popular in industrial production, despite the fact that these methods are labor intensive and/or generate toxic effluents. There has been an increasing demand for rapid, ecofriendly and relatively cheaper synthesis of nanostructures. Here, we propose a strategy, for one-minute green synthesis of AgNPs and a one-pot one-minute green synthesis of Au-Ag nanocomposite, using Melia azedarach bark aqueous extract as reducing agent. The hydrothermal mechanism of the autoclave technology has been successfully used in this study to accelerate the nucleation and growth of nano-crystals. The study also presents high antimicrobial potential of the synthesized nano solutions against common food and water born pathogens. The multistep characterization and analysis of the synthesized nanomaterial samples, using UV-visible spectroscopy, ICP-MS, FT-IR, EDX, XRD, HR-TEM and FE-SEM, also reveal the reaction dynamics of AgNO3, AuCl3 and plant extract in synthesis of the nanoparticles and nanocomposite. The antimicrobial effectiveness of the synthesized Au-Ag nanocomposite, with high gold to silver ratio, reduces the dependency on the AgNPs, which is considered to be environmentally more toxic than the gold counterpart. We hope that this new strategy will change the present course of green synthesis. The rapidity of synthesis will also help in industrial scale green production of nanostructures using Melia azedarach.

  14. Model tests for corrosion influence of electrode surface on electroosmosis in marine sludge

    Science.gov (United States)

    Zheng, Lingwei; Li, Jinzhu; Shi, Hanru

    2017-11-01

    The corrosion of metal electrodes is inevitable on electroosmosis in soil. Surface corrosion of electrodes is also one of the reasons for increasing energy consumption in electroosmosis treatment. A series of laboratory tests were conducted employing three kinds of materials, aluminium, steel, and brass. To explore the impact of surface corrosion degree on electroosmosis, metal electrodes were pretreated with durations 0 h, 12 h, 24 h, and 36 h. After the pretreatment, corroded electrodes are used as anodes on electroosmosis. Water discharge, current, voltage potential were measured during the tests; water content was also tested at three points after the electroosmosis. The results showed that aluminium was better than steel in electroosmotic drainage while brass provided the worst dewatering performance. Surface corrosion did not influence the aluminium and steel on electroosmosis in marine sludge, but brass did. In the pretreatment of brass electrodes, corrosion rate had started to slow down at later periods, with the deterioration rate of dewatering reduced afterwards. As the results showed, it is not recommended to employ those easily deteriorated electrode materials from surface corrosion in practical engineering, such as brass; electrode material with higher electroosmosis exchange rate is recommended, such as aluminium.

  15. The Au-Ag-Sb-Bi-Te mineralization from the deposit Bytíz (mine 19), the Příbram uranium-polymetallic ore discrit, Czech Republic

    Czech Academy of Sciences Publication Activity Database

    Litochleb, J.; Sejkora, J.; Šrein, Vladimír

    2006-01-01

    Roč. 28, Spec. pap. (2006), s. 133-135 ISSN 1896-2203. [Central European Mineralogical Conference /1./. Vyšná Boca, 11.09.2006-15.09.2006] Institutional research plan: CEZ:AV0Z30460519 Keywords : Au-Ag-Sb-Bi-Te * mineralization * uranium-polymetallic ore Subject RIV: DB - Geology ; Mineralogy

  16. Colorimetric detection of hydrogen peroxide and lactate based on the etching of the carbon based Au-Ag bimetallic nanocomposite synthesized by carbon dots as the reductant and stabilizer

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Lin; Hou, Wenli; Lu, Qiujun; Liu, Meiling, E-mail: liumeilingww@126.com; Chen, Chao; Zhang, Youyu; Yao, Shouzhuo

    2016-12-01

    In this report, carbon-based gold core silver shell Au-Ag bimetallic nanocomposite (Au-Ag/C NC) was synthesized using carbon dots (C-dots) as the reductant and stabilizer by a facile green sequential reduction approach. The structure and morphology of the nanocomposite are characterized by ultraviolet–visible spectroscopy (UV–Vis), Fourier transform infrared spectroscopy (FT-IR) and transmission electron microscopy (TEM). The as synthesized Au-Ag/C NC exhibits good optic response toward hydrogen peroxide (H{sub 2}O{sub 2}) without adding any other chromogenic agents. The characteristic surface plasmon resonance (SPR) absorbance peak of Au-Ag/C NC declined and red-shifted with the solution color changing from reddish orange to light pink when adding H{sub 2}O{sub 2} owing to the etching effect of H{sub 2}O{sub 2} towards Ag. Thus, a simple colorimetric and UV strategy for sensitive detection of H{sub 2}O{sub 2} is proposed. It provides the wide linear range for detection of H{sub 2}O{sub 2} from 0.8–90 μM and 90–500 μM, and the detection limit was as low as 0.3 μM (S/N = 3). In addition, this colorimetric strategy can also be applied to directly distinguish and detect of lactate by naked eye and UV–Vis. The linear range of colorimetric sensing towards lactate was 0.1–22 μM and 22–220 μM, which was successfully applied in the analysis of lactate in human serum. - Highlights: • Carbon-based AuAg bimetallic nanocomposite was synthesized using carbon dots. • The as synthesized Au-Ag/C NC exhibits good optic response toward H{sub 2}O{sub 2}. • The SPR absorbance of Au-Ag declined and red-shifted with the color change. • A simple colorimetric and UV strategy for sensitive detection of H{sub 2}O{sub 2} is proposed. • This colorimetric strategy can also be applied in detection of lactate by naked eye.

  17. Tracer Studies of the Influence of Foreign Substances at the Surface of the Electrodes. II Influence in electro crystallization phenomena

    International Nuclear Information System (INIS)

    Llopis, J.; Gamboa, J. M.; Arizmendi, L.

    1963-01-01

    The action of foreign substances present on the surface of the electrodes, in electro crystallization phenomena, has been studied. The number of Ag crystals per square centimeter of Pt electrode varies with the polishing, the current density and the presence of multilayers of stearic acid. The statistical distribution of Ag crystals without and with multilayers and their influence on the concentration index and the deformation of Ag crystals has been studied. the size of these crystals increases as the current density decreases. (Author) 16 refs

  18. Mineralogy and geochemical environment of formation of the Perama Hill high-sulfidation epithermal Au-Ag-Te-Se deposit, Petrota Graben, NE Greece

    Science.gov (United States)

    Voudouris, Panagiotis Christos; Melfos, Vasilios; Spry, Paul G.; Moritz, Robert; Papavassiliou, Constantinos; Falalakis, George

    2011-11-01

    The Perama Hill deposit is a high-sulfidation Au-Ag-Te-Se epithermal system hosted in silicic- and argillic altered andesitic rocks and overlying sandstones, which were emplaced on the eastern margin of the Petrota graben, northeastern Greece. The deposit evolved from an early stage silica-pyrite rock and argillic alteration followed by the deposition of sulfide-, sulfosalt- and telluride-bearing quartz-barite veins and stockworks. Early ore formation is characterized by a high-sulfidation-type enargite-galena-bearing ore assemblage (consisting of enargite, watanabeite, Fe-free sphalerite, covellite, kesterite, bismuthinite, selenian bismuthinite, lillianite homologues, kawazulite-tetradymite, goldfieldite, and native gold), followed by the formation of an intermediate-sulfidation-type tennantite-bearing assemblage characterized by ferrian/zincian tennantite, tellurobismuthite, tetradymite, melonite, native tellurium, Au-Ag-tellurides (calaverite, krennerite, sylvanite, hessite, petzite, stützite), altaite and electrum. Quartz, barite, kaolinite, sericite and minor aluminum-phosphate-sulfate minerals are gangue minerals. Fluid inclusion data demonstrate that the ore system evolved from an initial high temperature (up to 330°C) and low salinity (up to 4.9 wt.% NaCl equiv.) fluid towards a cooler (200°C) and very low salinity (0.7 wt.% NaCl equiv.) hydrothermal fluid suggesting progressive cooling and dilution of the ore fluid. The ore minerals at Perama Hill reflect variable fS2 and fTe2 conditions during base and precious metal deposition. Early ore deposition took place at ~300°C, at log fS2 values between ≈-8.2 and -5.5, and log fTe2 from -11.8 and -7.8. Late ore deposition occurred at log fS2 = -11.8 to -9.8 and log fTe2 of ≈-9.2 and -7.8. These data and paragenetic studies indicate a shift towards higher log fTe2 and lower log fS2 and log fSe2 values for the mineralizing fluids with time. The kawazulite/tetradymitess-gold association at Perama Hill

  19. The influence of electrode configuration on light emission profiles and electrical characteristics of an atmospheric-pressure plasma jet

    Science.gov (United States)

    Maletić, Dejan; Puač, Nevena; Malović, Gordana; Đorđević, Antonije; Petrović, Zoran Lj

    2017-04-01

    In this paper we focus on the influence of the type of electrodes, their dimensions and inter-electrode gap on the formation of a helium plasma jet. Plasma emission profiles are recorded by an ICCD camera simultaneously with volt-ampere characteristics for three different copper electrode configurations. The delivered power was up to 6.5 W, but it may be set and controlled to 0.1 W. This study shows how the electrode configuration shapes and controls temporal and spatial plasma development as well as electrical characteristics of an atmospheric pressure plasma jet. It is shown that, in our system, the width of the grounded electrode has no significant influence on the formation and properties of pulsed atmospheric-pressure streamers (PAPS) outside the tube, while the width of the powered electrode is crucial in their formation.

  20. The behaviour of the elements Ni, Co, Cu, Pb, Zn, Au, Ag, Mo, Sn, W and U in the magmatic, hydrothermal, sedimentary and weathering environments

    International Nuclear Information System (INIS)

    Anderson, J.R.

    1978-01-01

    In the last two decades much has been published on the behaviour of certain elements in the magmatic, hydrothermal, sedimentary and weathering environments, but the information is scattered throughout the literature. This situation prompted the present study on the elements Ni, Co, Cu, Pb, Zn, Au, Ag, Mo, Sn, W and U. The behaviour of the elements Ni, Cu, Pb, Zn, Au, Sn, W and U has been studied experimentally in some depth. Ag has been moderately studied, but there is very little information about Co and Mo. Studies on the complexes formed by the elements within the hydrothermal and aqueous environment are often inconclusive and controversial, but conclusions are drawn as to the more likely complexes formed. A genetic classification of ore deposits is used as a framework for the discussion. The source of the elements is regarded as being the mantle, and therefore discussion on other possible sources is beyond the scope of this dissertation. The crystal chemistry and geochemistry of the elements are presented and the essay concludes with a discussion on the elements within their depositional environments

  1. The influence of electrode angle on the minimization of the aberration coefficients of the two electrodes electrostatic immersion lens

    International Nuclear Information System (INIS)

    Al-Khashab, M. A.; Ahmad, A. A.

    2012-01-01

    This paper deals with electron optical properties of a set asymmetrical electrostatic immersion lenses with two electrodes which have been designed using different angles (θ) of the outer lens electrodes as well as air gaps (S) between the electrodes of each lens. It was found that the angle of the outer electrode and the air gap have a clear effect on the electron optical performance of such lenses. In addition to that, it was noticed that the better electron optical properties occurred when the angle of the outer electrode equals (θ = O d egree) and the air gap equals (S = 11 mm). the results of the perferable design of the prsent work were compared with those in published papers in terms of the optical properties. It was found that results are in good agreement with each other. (authors).

  2. Insights into the genesis of the epithermal Au-Ag mineralization at Rio Blanco in the Cordillera Occidental of southwestern Ecuador: Constraints from U-Pb and Ar/Ar geochronology

    Science.gov (United States)

    Bineli Betsi, Thierry; Ponce, Miguel; Chiaradia, Massimo; Ulianov, Alex; Camacho, Alfredo

    2017-12-01

    The genesis of the Au-Ag mineralization at Rio Blanco in the Cordillera Occidental (Western Cordillera) of southwest of Ecuador is here constrained. This was done by investigating the temporal and by inference the genetic relationship between the Au-Ag mineralization and the spatially associated magmatic host rocks using zircon U-Pb [chemical abrasion (CA) IDTIMS and laser ablation (LA) ICPMS] and adularia 40Ar/39Ar geochronology. Whereas volcanics hosting the Au-Au mineralization range in age from 37.35 ± 0.30 to 33.09 ± 0.20 Ma (Late Eocene-Early Oligocene), the spatially associated intrusions are of at least two discontinuous phases of magmatism and these include: (i) Late Eocene intrusions that range in age from 35.77 ± 0.19 to 36.03 ± 0.19 Ma, and; (ii) Miocene intrusions of 15.58 ± 0.04 Ma. The 40Ar/39Ar age of adularia from a Bonanza Au (334 g/t)-Ag (2060 g/t)-bearing epithermal vein is bracketed between 14.3 and 14.9 Ma. The temporal relationship between adularia and by inference mineralization and the spatially associated rocks therefore rules out any temporal link between the Late Eocene-Early Oligocene Rio Blanco Formation, but rather favors a possible genetic relationship between the Rio Blanco Au-Ag mineralization and the Miocene intrusions. The determined Rio Blanco Au-Ag mineralization age is consistent with the established Oligocene-Miocene period of ore deposits in Ecuador and coincides with the extensional tectonic event, which developed intramontane basins in southern Ecuador.

  3. Colorimetric detection of hydrogen peroxide and lactate based on the etching of the carbon based Au-Ag bimetallic nanocomposite synthesized by carbon dots as the reductant and stabilizer.

    Science.gov (United States)

    Zhang, Lin; Hou, Wenli; Lu, Qiujun; Liu, Meiling; Chen, Chao; Zhang, Youyu; Yao, Shouzhuo

    2016-12-01

    In this report, carbon-based gold core silver shell Au-Ag bimetallic nanocomposite (Au-Ag/C NC) was synthesized using carbon dots (C-dots) as the reductant and stabilizer by a facile green sequential reduction approach. The structure and morphology of the nanocomposite are characterized by ultraviolet-visible spectroscopy (UV-Vis), Fourier transform infrared spectroscopy (FT-IR) and transmission electron microscopy (TEM). The as synthesized Au-Ag/C NC exhibits good optic response toward hydrogen peroxide (H 2 O 2 ) without adding any other chromogenic agents. The characteristic surface plasmon resonance (SPR) absorbance peak of Au-Ag/C NC declined and red-shifted with the solution color changing from reddish orange to light pink when adding H 2 O 2 owing to the etching effect of H 2 O 2 towards Ag. Thus, a simple colorimetric and UV strategy for sensitive detection of H 2 O 2 is proposed. It provides the wide linear range for detection of H 2 O 2 from 0.8-90 μM and 90-500 μM, and the detection limit was as low as 0.3 μM (S/N = 3). In addition, this colorimetric strategy can also be applied to directly distinguish and detect of lactate by naked eye and UV-Vis. The linear range of colorimetric sensing towards lactate was 0.1-22 μM and 22-220 μM, which was successfully applied in the analysis of lactate in human serum. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Chlorine triggered de-alloying of AuAg@Carbon nanodots: Towards fabrication of a dual signalling assay combining the plasmonic property of bimetallic alloy nanoparticles and photoluminescence of carbon nanodots

    Energy Technology Data Exchange (ETDEWEB)

    Mohammadpour, Zahra; Safavi, Afsaneh, E-mail: safavi@susc.ac.ir; Abdollahi, Seyyed Hossein

    2017-03-22

    Integration of Au-Ag alloy and fluorescent carbon nanodots (C-dots) into a single platform resulted in a new dual sensing assay for chlorine. Selective etching of Ag from AuAg@C-dots was transformed into: (i) colorimetric signal by surface plasmon resonance (SPR) tuning of the alloy and (ii) fluorimetric signal by perturbation of fluorescence energy transfer between C-dots and alloy nanoparticles. Fast oxidizing of silver atoms incorporated in the bimetallic structure induced by chlorine resulted in selective de-alloying of bimetallic hybrid nanoparticles and an intense visible change of the colloidal dispersion color. On the other hand, the systematic change in Au/Ag ratio strongly affected the emission intensity of C-dots in the hybrid structure leading to an enhancement in the fluorescence signal. Thus, the assay enables the detection of chlorine both under visible and UV lights with high sensitivity. The detection limit (DL) values were calculated as 6.2 × 10{sup −7} M and 5.1 × 10{sup −7} M through colorimetric and fluorimetric pathways, respectively. Most importantly, it was demonstrated to be selective over common cations, anions and some reactive oxygen species (ROS). This assay was successfully applied to the determination of chlorine concentration in bleach solution and tap water. It is robust and is suitable for cost effective chlorine measurement in environmental samples. - Highlights: • A new dual signalling assay for hypochlorite ion is introduced. • Bimetallic Au-Ag nanoparticles are hybridized with fluorescent carbon nanodots. • It shows amplified colorimetric response with respect to monometallic counterparts. • This sensor is multifunctional, robust, rapid and sensitive. • The practical applicability is investigated for environmental monitoring.

  5. Influence of nonionic surfactants on the potentiometric response of hydrogen ion-selective polymeric membrane electrodes.

    Science.gov (United States)

    Espadas-Torre, C; Bakker, E; Barker, S; Meyerhoff, M E

    1996-05-01

    The influence of poly(ethylene oxide)-based nonionic surfactants (i.e., Triton X-100 and Brij 35) in the sample phase on the response properties of hydrogen ion-selective polymeric membrane electrodes containing mobile (lipophilic amines) or covalently bound (aminated-poly-(vinyl chloride)) hydrogen ion carriers is reported. In the presence of these nonionic surfactants, membrane electrode response toward interfering cation activity (e.g., Na+) in the sample phase is increased substantially and the pH measuring range shortened. The degree of cation interference for pH measurements is shown to correlate with the basicity of the hydrogen ion carrier doped within the membrane phase. The observed deterioration in selectivity arises from the partitioning of the surfactant into the membrane and concomitant extraction of metal cations by the surfactants in the organic phase. The effect of nonionic surfactants on pH electrodes prepared with aminated-PVC membranes is shown to be more complex, with additional large shifts in EMF values apparently arising from multidentate interactions between the surfactant molecules and the polymeric amine in the membrane, leading to a change in the apparent pKa values for the amine sites. The effects induced by nonionic surfactants on the EMF response function of hydrogen ion-selective polymeric membrane electrodes are modeled, and experimental results are shown to correlate well with theoretical predictions.

  6. The influence of negative current collector size on a liquid metal positive electrode

    Science.gov (United States)

    Mohammad, Ibrahim; Ashour, Rakan; Kelley, Douglas

    2017-11-01

    Fluid mixing in the positive electrode of a liquid metal battery (LMB) governs some performance-related factors such as the rate of charge and discharge of the battery. The negative current collector (NCC) of a LMB is always smaller than the positive current collector, implying that current is convergent at the NCC. Also, different NCC sizes introduce different thermal, electromagnetic, and flow boundary conditions. In this talk, I will show how our lab studies the influence of NCC diameter on the flow in a liquid metal positive electrode driven by electrical current. I will present measurements of the flow velocity taken via Ultrasonic Doppler Velocimetry (UDV) over a range of different currents, at different NCC diameters.

  7. Influence of Surgical Staples on Radiofrequency Ablation Using Multitined Expandable Electrodes

    International Nuclear Information System (INIS)

    Sakuhara, Yusuke; Shimizu, Tadashi; Abo, Daisuke; Hasegawa, Yu; Kato, Fumi; Kodama, Yoshihisa; Shirato, Hiroki

    2007-01-01

    Purpose. During radiofrequency ablation (RFA), there is a risk that the multitined expandable electrode will come into contact with one of the surgical staples used to treat local recurrence after surgical operations. Our objective was to evaluate whether a surgical staple would influence the RFA of egg white using a multitined expandable electrode. Methods. Multitined expandable electrodes, LeVeen needles (expandable diameter 3.0 cm), were sunk into an egg white bath with (a) no surgical staple, (b) a surgical staple touching one of the tines, or (c) a surgical staple touching two of the tines simultaneously. By connecting the LeVeen needle and copper plate at the bottom of the bath, RFA was then performed on the egg whites as a substitute for human tissue. Ten egg white baths were ablated under each of conditions (a), (b), and (c), for a total of 30 sets of coagulated egg white. Results. There was no significant difference in the time from the power-on to the roll-off (i.e., the completion and shutting off of the electric circuit) or in the maximum diameter of the thermal lesion between conditions (a) and (b) or (a) and (c). However, the minimum diameter of the thermal lesion was significantly smaller in (c) compared with (a) (p < 0.01). Conclusions. Surgical staples have the capacity to interfere with the electromagnetic field and decrease the minimum diameter of the thermal lesion in the event that a staple touches two of the tines of a multitined expandable electrode during RFA. Although the difference might be small enough to be neglected under many clinical circumstances, we recommend that, if possible, the tines not be expanded near metallic material

  8. Hydrologic models of modern and fossil geothermal systems in the Great Basin: Genetic implications for epithermal Au-Ag and Carlin-type gold deposits

    Science.gov (United States)

    Person, M.; Banerjee, A.; Hofstra, A.; Sweetkind, D.; Gao, Y.

    2008-01-01

    The Great Basin region in the western United States contains active geothermal systems, large epithermal Au-Ag deposits, and world-class Carlin-type gold deposits. Temperature profiles, fluid inclusion studies, and isotopic evidence suggest that modern and fossil hydrothermal systems associated with gold mineralization share many common features, including the absence of a clear magmatic fluid source, discharge areas restricted to fault zones, and remarkably high temperatures (>200 ??C) at shallow depths (200-1500 m). While the plumbing of these systems varies, geochemical and isotopic data collected at the Dixie Valley and Beowawe geothermal systems suggest that fluid circulation along fault zones was relatively deep (>5 km) and comprised of relatively unexchanged Pleistocene meteoric water with small (horizons. Those with minimal fluid ?? 18O shifts are restricted to high-permeability fault zones and relatively small-scale (???5 km), single-pass flow systems (e.g., Beowawe). Those with intermediate to large isotopic shifts (e.g., epithermal and Carlin-type Au) had larger-scale (???15 km) loop convection cells with a greater component of flow through marine sedimentary rocks at lower water/rock ratios and greater endowments of gold. Enthalpy calculations constrain the duration of Carlin-type gold systems to probably account for the amount of silica in the sinter deposits. In the Carlin trend, fluid circulation extended down into Paleozoic siliciclastic rocks, which afforded more mixing with isotopically enriched higher enthalpy fluids. Computed fission track ages along the Carlin trend included the convective effects, and ranged between 91.6 and 35.3 Ma. Older fission track ages occurred in zones of groundwater recharge, and the younger ages occurred in discharge areas. This is largely consistent with fission track ages reported in recent studies. We found that either an amagmatic system with more permeable faults (10-11 m2) or a magmatic system with less

  9. Induced accumulation of Au, Ag and Cu in Brassica napus grown in a mine tailings with the inoculation of Aspergillus niger and the application of two chemical compounds.

    Science.gov (United States)

    González-Valdez, Eduardo; Alarcón, Alejandro; Ferrera-Cerrato, Ronald; Vega-Carrillo, Héctor René; Maldonado-Vega, María; Salas-Luévano, Miguel Ángel; Argumedo-Delira, Rosalba

    2018-06-15

    This study evaluated the ability of Brassica napus for extracting gold (Au), silver (Ag) and copper (Cu) from a mine tailings, with the inoculation of two Aspergillus niger strains, and the application of ammonium thiocyanate (NH 4 SCN) or ammonium thiosulfate [(NH 4 ) 2 S 2 O 3 ]. After seven weeks of growth inoculated or non-inoculated plants were applied with 1 or 2 g kg -1 of either NH 4 SCN or (NH 4 ) 2 S 2 O 3 , respectively. Eight days after the application of the chemical compounds, plants were harvested for determining the total dry biomass, and the content of Au, Ag, and Cu in plant organs. Application of (NH 4 ) 2 S 2 O 3 or NH 4 SCN resulted in enhanced Au-accumulation in stems (447% and 507%, respectively), while either (NH 4 ) 2 S 2 O 3 +Aspergillus, or NH 4 SCN increased the Au-accumulation in roots (198.5% and 404%, respectively) when compared to the control. Treatments with (NH 4 ) 2 S 2 O 3 or (NH 4 ) 2 S 2 O 3 +Aspergillus significantly increased (P ≤ 0.001) the accumulation of Ag in leaves (677% and 1376%, respectively), while NH 4 SCN + Aspergillus, and (NH 4 ) 2 S 2 O 3 enhanced the accumulation in stems (7153% and 6717.5%). The Ag-accumulation in roots was stimulated by NH 4 SCN+ Aspergillus, and (NH 4 ) 2 S 2 O 3 + Aspergillus (132.5% and 178%, respectively), when compared to the control. The combination of NH 4 SCN+Aspergillus significantly enhanced the Cu-accumulation in leaves (228%); whereas NH 4 SCN+ Aspergillus, or (NH 4 ) 2 S 2 O 3 + Aspergillus resulted in greater accumulation of Cu in stems (1233.5% and 1580%, respectively) than the control. Results suggest that either NH 4 SCN or (NH 4 ) 2 S 2 O 3 (with or without Aspergillus) improved the accumulation of Au and Ag by B. napus. Accumulation of Au and Ag in plant organs overpassed the hyperaccumulation criterion (> 1 mg kg -1 of plant biomass); whereas Cu-accumulation in stems and roots also overpassed such criterion (> 1000 mg kg -1 ) by applying

  10. Influence of thin film thickness of working electrodes on photovoltaic characteristics of dye-sensitized solar cells

    Directory of Open Access Journals (Sweden)

    Lai Yeong-Lin

    2017-01-01

    Full Text Available This paper presents the study of the influence of thin film thickness of working electrodes on the photovoltaic characteristics of dye-sensitized solar cells. Titanium dioxide (TiO2 thin films, with the thickness from 7.67 to 24.3 μm, were used to fabricate the working electrodes of dye-sensitized solar cells (DSSCs. A TiO2 film was coated on a fluorine-doped tin oxide (FTO conductive glass substrate and then sintered in a high-temperature furnace. On the other hand, platinum (Pt solution was coated onto an FTO substrate for the fabrication of the counter electrode of a DSSC. The working electrode immersed in a dye, the counter electrode, and the electrolyte were assembled to complete a sandwich-structure DSSC. The material analysis of the TiO2 films of DSSCs was carried out by scanning electron microscopy (SEM and ultraviolet-visible (UV-Vis spectroscopy, while the photovoltaic characteristics of DSSCs were measured by an AM-1.5 sunlight simulator. The light transmittance characteristics of the TiO2 working electrode depend on the TiO2 film thickness. The thin film thickness of the working electrode also affects the light absorption of a dye and results in the photovoltaic characteristics of the DSSC, including open-circuited voltage (VOC, short-circuited current density (JSC, fill factor, and photovoltaic conversion efficiency.

  11. Influence of the plain-parallel electrode surface dimensions on the type A measurement uncertainty of GM counter

    Directory of Open Access Journals (Sweden)

    Stanković Koviljka Đ.

    2011-01-01

    Full Text Available This paper investigates, through theory and experiment, the influence of the plain-parallel electrode surface dimensions change on the type A measurement uncertainty of a GM counter. The possibilities of applying these results to practical structures are examined by using the methods of mathematical statistics. Special attention is devoted to the influence of electrode surface enlargement on the statistical behavior of the pulse number random variable, expressed in the form of the enlargement law. In the theoretical part of the paper, the general surface enlargement law is derived. Comparison of experimental results with those predicted by the surface enlargement law proved its validity for expressing the type A measurement uncertainty of GM counters constructed with a plain-parallel electrode configuration with a homogenous electric field.

  12. Influence of surface states of CuInS{sub 2} quantum dots in quantum dots sensitized photo-electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Zhuoyin; Liu, Yueli [State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, School of Materials Science and Engineering, Wuhan University of Technology, Wuhan 430070 (China); Wu, Lei [School of Electronic and Electrical, Wuhan Railway Vocational College of Technology, Wuhan 430205 (China); Zhao, Yinghan; Chen, Keqiang [State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, School of Materials Science and Engineering, Wuhan University of Technology, Wuhan 430070 (China); Chen, Wen, E-mail: chenw@whut.edu.cn [State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, School of Materials Science and Engineering, Wuhan University of Technology, Wuhan 430070 (China)

    2016-12-01

    Graphical abstract: J–V curves of different ligands capped CuInS{sub 2} QDs sensitized TiO{sub 2} photo-electrodes. - Highlights: • DDT, OLA, MPA, and S{sup 2−} ligand capped CuInS{sub 2} quantum dot sensitized photo-electrodes are prepared. • Surface states of quantum dots greatly influence the electrochemical performance of CuInS{sub 2} quantum dot sensitized photo-electrodes. • S{sup 2−} ligand enhances the UV–vis absorption and electron–hole separation property as well as the excellent charge transfer performance of the photo-electrodes. - Abstract: Surface states are significant factor for the enhancement of electrochemical performance in CuInS{sub 2} quantum dot sensitized photo-electrodes. DDT, OLA, MPA, and S{sup 2−} ligand capped CuInS{sub 2} quantum dot sensitized photo-electrodes are prepared by thermolysis, solvethermal and ligand-exchange processes, respectively, and their optical properties and photoelectrochemical properties are investigated. The S{sup 2−} ligand enhances the UV–vis absorption and electron–hole separation property as well as the excellent charge transfer performance of the photo-electrodes, which is attributed to the fact that the atomic S{sup 2−} ligand for the interfacial region of quantum dots may improve the electron transfer rate. These S{sup 2−}-capped CuInS{sub 2} quantum dot sensitized photo-electrodes exhibit the excellent photoelectrochemical efficiency and IPCE peak value, which is higher than that of the samples with DDT, OLA and MPA ligands.

  13. Conditions pertaining to the influence of electrode surface roughness upon the insulation strength of compressed SF6 systems

    DEFF Research Database (Denmark)

    McAllister, Iain Wilson; Crichton, George C

    1997-01-01

    On the basis of a series of experimental investigations reported in the literature, electrode microscopic surface roughness was dismissed as a factor influencing breakdown levels in compressed SF6, irrespective of field non-uniformity. This conclusion appears to be tenable if one restricts observ...

  14. Influence of the sample volume and the position of the electrode and the capillary-end in the sample vial on the electrokinetic injection in capillary electrophoresis

    NARCIS (Netherlands)

    Ensing, K

    1997-01-01

    The influence of the positions of the electrode and the capillary-end and volume in the sample vials on the electrokinetically injected amount of the analytes in capillary electrophoresis was studied. The influence may be reduced by using a more or less fixed position of the electrode and the

  15. Generation of Au(p)Ag(q)Te(r) clusters via laser ablation synthesis using Au-Ag-Te nano-composite as precursor: quadrupole ion-trap time-of-flight mass spectrometry.

    Science.gov (United States)

    Mawale, Ravi Madhukar; Amato, Filippo; Alberti, Milan; Havel, Josef

    2014-07-30

    Metal tellurides have applications in various fields of science and technology but only a few gold-silver tellurides have been reported. The laser ablation synthesis (LAS) method allows the preparation of nano-materials from solid substrates. Therefore, this method was selected to synthesise some gold-silver tellurides. Laser desorption ionisation quadrupole ion trap time-of-flight mass spectrometry (LDI QIT TOF MS) was used for the generation of new Au(p)Ag(q)Te(r) clusters. Scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX) were used to characterise the materials. The stoichiometry of the clusters generated was determined via collision-induced dissociation (CID) and modeling of isotopic patterns. Chemisorption of gold and silver nano-particles on tellurium powder led to the formation of a new kind of Au-Ag-Te nano-composite. The LDI of this nano-composite yielded nine unary (Ag(q), Te(r)), 40 binary (Au(p)Te(r) and Ag(p)Te(r)) and 78 ternary clusters. The stoichiometry of these novel Au(p)Ag(q)Te(r) clusters is reported here for the first time. The new Au-Ag-Te nano-composite was found to be a more suitable precursor for the generation of clusters than the mixtures of the elements. TOF MS was shown to be a useful technique for following the generation of gold-silver tellurides. Knowledge of the cluster stoichiometry could accelerate the further development of novel high-tech materials such as chalcogenide glasses. Copyright © 2014 John Wiley & Sons, Ltd.

  16. DFT study of Hg adsorption on M-substituted Pd(1 1 1) and PdM/γ-Al2O3(1 1 0) (M = Au, Ag, Cu) surfaces

    Science.gov (United States)

    Wang, Jiancheng; Yu, Huafeng; Geng, Lu; Liu, Jianwen; Han, Lina; Chang, Liping; Feng, Gang; Ling, Lixia

    2015-11-01

    The adsorption of Hgn (n = 1-3) on the Au-, Ag-, Cu-substituted Pd(1 1 1) surfaces as well as the PdM/γ-Al2O3(1 1 0) (M = Au, Ag, Cu) surfaces has been investigated using spin-polarized density functional theory calculations. It is found that M-substituted Pd(1 1 1) surfaces show as good Hg adsorption capacity as the perfect Pd(1 1 1) at low Hg coverage, while the Hg adsorption capacity is only slightly weakened at high Hg coverage. On the basis of stepwise adsorption energies analysis, it is concluded that M-substituted Pd(1 1 1) surfaces can contribute to the binding of Hg atom on the surfaces at high Hg coverage. The electronic properties of the second metal atoms are the main factor contributes to the Hg adsorption capacity. Gas phase Pd2 shows better Hg adsorption capacity than Pd2/γ-Al2O3, while PdM/γ-Al2O3 can adsorb Hg more efficiently than bare PdM clusters. It suggests that the γ-Al2O3 support can enhance the activity of PdM for Hg adsorption and reduces the activity of Pd2. It is also found that Pd is the main active composition responsible for the interaction of mercury with the surface for PdM/γ-Al2O3 sorbent. Taking Hg adsorption capacity and economic costs into account, Cu addition is a comparatively good candidate for Hg capture.

  17. Influence of the crystallographic structure of the electrode surface on the structure of the electrical double layer and adsorption of organic molecules

    International Nuclear Information System (INIS)

    Kochorovski, Z.; Zagorska, I.; Pruzhkovska-Drakhal, R.; Trasatti, S.

    1995-01-01

    The results of systematic investigation of influence of crystal structure of Bi-, Sb- and Cd-electrode surfaces on regularities of double electric layer structure in aqueous and nonaqueous solutions of surface-nonactive electrolyte are given. Influence of electrode surface characteristics on adsorptive behaviour of different organic molecules has been studied. General regularities of of chemical nature influence and surface crystallographic structure on the double layer structure and on organic compounds adsorption have been established. 57 refs., 7 figs., 4 tabs

  18. Tracer Studies of the Influence of Foreign Substances at the Surface of the Electrodes. I. Polarization Phenomena

    International Nuclear Information System (INIS)

    Llopis, J.; Gamboa, J. M.; Arizmendi, L.

    1961-01-01

    Radioactive stearic acid ( 1 4C) has been used to determine the number of molecular layers present on copper electrode surfaces and its distribution. The stability of these layers under the experimental conditions has been studied and it has been shown that its presence has no influence on the anodic and cathodic polarization. an increase of these polarizations has been observed with mixed multilayers of stearic acid and sterolamide. (Author) 13 refs

  19. FUEL CELL ELECTRODE MATERIALS

    Science.gov (United States)

    FUEL CELL ELECTRODE MATERIALS. RAW MATERIAL SELECTION INFLUENCES POLARIZATION BUT IS NOT A SINGLE CONTROLLING FACTOR. AVAILABLE...DATA INDICATES THAT AN INTERRELATIONSHIP OF POROSITY, AVERAGE PORE VOLUME, AND PERMEABILITY CONTRIBUTES TO ELECTRODE FUEL CELL BEHAVIOR.

  20. Influence of structure and hydrophobic properties on the characteristics of carbon-air electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Shteinberg, G.V.; Dribinsky, A.V.; Kukushkina, I.A.; Musiliva, M.; Mrha, J.

    1982-07-01

    The electrochemical parameters of carbon-oxygen gas-diffusion electrodes can be controlled over a wide range by varying the structure of the active carbon catalyst and the ratio of lyophilic and lyophobic pores in the catalyst particles. Two typical representatives of active carbon catalysts with significantly different hydrophobic properties have been investigated by mercury-alkali intrusion porosimetry and tested both in model floating electrodes and as the hydrophilic component of the active layer of two-layer, gas-diffusion working electrodes. The optimal electrolyte content in the active layer ensuring the maximum electrical characteristics of working electrodes has been found to depend on the structure and hydrophobic properties of the carbon catalyst. The gas pores in the carbon catalyst have been shown to play an essential role in the oxygen mass transfer process in the active layer.

  1. The Influence of Electrodes and Conditioning on Space Charge Accumulation in XLPE

    DEFF Research Database (Denmark)

    Fleming, R. J.; Henriksen, Mogens; Holbøll, Joachim

    2000-01-01

    The accumulation of space charge in planar crosslinked polyethylene (XLPE) samples under dc electric fields at room temperature was investigated using the pulsed electroacoustic (PEA) method. Three different organic semiconductor (semicon) materials containing carbon black at concentrations ~30 %wt......, and vacuum-evaporated gold, were used as electrodes. Three different conditioning procedures were investigated. Unconditioned samples developed heterocharge with density increasing from zero at the electrodes, to a maximum at roughly one-third of the thickness, and then falling to zero around the center....... They also developed homocharge close to the electrodes. The choice of electrode material had little effect on the heterocharge profile in unconditioned samples. Conditioning by holding at 80°C for four days, at rotary pump pressure or at atmospheric pressure, suppressed the accumulation of heterocharge...

  2. Influence of BaO in perovskite electrodes for the electrochemical reduction of NOx

    DEFF Research Database (Denmark)

    Simonsen, Vibe Louise Ernlund; Johnsen, M.M.; Kammer Hansen, Kent

    2007-01-01

    Using the point electrode method, the effect of BaO on electrochemical reduction of NO (x) was investigated using the perovskites La0.85Sr0.15MnO3 (LSM15) and La0.85Sr0.15CoO3 (LSCo15) as electrode materials. The experiments were carried out in the temperature range 400-600 degrees C in 1% NO and...

  3. Influence of various metallic oxides on the kinetic of the oxygen evolution reaction on platinum electrodes

    Directory of Open Access Journals (Sweden)

    Kambire Ollo

    2015-08-01

    Full Text Available Pt, 50Pt-50RuO2 and 50Pt-50IrO2 electrodes were prepared on titanium (Ti substrate by thermal decomposition techniques. The micrographs of 50Pt-50RuO2 and 50Pt-50IrO2 have revealed that their surfaces are rough with cracked structures. That of platinum was smooth, compact and homogeneous. The richer the electrode ‘surface in platinum, thinner is the crack size and also more compact is the electrode’surface. The electrodes have also been characterized electrochemically by cyclic voltammetry in acid (HClO4 and in alkaline (KOH electrolytes. These characterizations showed that the surface of the 50Pt-50RuO2 and 50Pt-50IrO2 electrodes were composed by platinum and metal dioxide active sites. The Tafel slope obtained on Pt, 50Pt-50RuO2 and 50Pt-50IrO2 for the oxygen evolution reaction (OER were respectively 120, 90 and 44 mV/dec in acid electrolyte. In the alkaline electrolyte, they were 119, 87 and 42 mV/dec respectively on Pt, 50Pt-50RuO2 and 50Pt-50IrO2 electrodes indicating that for the prepared electrodes, Tafel slopes are the same in acid and in alkaline media. Moreover, in acid and in alkaline media, the kinetic of the oxygen evolution reaction was rapid on 50Pt-50RuO2 and 50Pt-50IrO2 than Pt owing to a synergetic effect of Pt and the oxides. That additional effect of the surface component 50Pt-50RuO2 and 50Pt-50IrO2 electrodes let them possess high electrocatalytic activity towards OER than Pt in the two media. Though the kinetic of the oxygen evolution reaction is practically the same in acidic and alkaline media for all the electrodes, OER occurred at lower overpotential in alkaline electrolyte than in acidic electrolyte on the prepared electrodes.

  4. Influence of the electrode wear on the EUV generation of a discharge based extreme ultraviolet light source

    Science.gov (United States)

    Vieker, Jochen; Bergmann, Klaus

    2017-08-01

    Reliability and a long maintenance interval are major requirements for the industrial use of an extreme ultraviolet (EUV) source. In this paper we present results on the influence of the electrode erosion on the EUV generation and its lifetime limiting characteristics. The geometry of the electrodes and their influence on the gas pressure distribution within the electrode system have been found to be the key variables to characterize the regime of operation. This better understanding allows for an optimization of device parameters (e.g. gas flow or pulse energy) to counteract the erosion process, in order to increase the maintenance interval and EUV output. The EUV source under investigation is based on a hollow cathode triggered pinch plasma. A new trigger concept is introduced that enables free adjustment of the gas pressure during operation, thus enabling the operation with a high conversion efficiency of up to  >0.7 %/2πsr at 13.5 nm and 2% bandwidth. The efficiency for the peak brilliance is up to ~2.6 W kW-1 mm-2sr-1 while the maximum electrical input power of the system is 15 kW.

  5. Influence of water on the anodic oxidation mechanism of diethylenetriamine (deta on platinum electrode

    Directory of Open Access Journals (Sweden)

    Lassine Ouattara

    2006-12-01

    Full Text Available Diethylenetriamine was oxidised in different electrolytes on platinum electrode. In non-aqueous electrolyte, an irreversible oxidation peak characteristic of DETA oxidation appears on the voltammogram followed by a constant current until the higher limit of the sweeping potential domain is attained. The following successive scans showed a high decrease of the current intensity and that is due to the formation of an insulating coating layer on the electrode surface. When water is added to the non-aqueous electrolyte, a DETA oxidation wave appears on the voltammograms. That oxidation wave is observed on the following scans. Indeed, DETA oxidation mechanism seems to be different either the electrolyte is free or not of water. In non-aqueous electrolyte, DETA oxidation leads to electrode surface covering by a thin polymeric film but in water containing electrolyte, oxygen evolution occurs and DETA oxidation leads to uncoated surface by producing aldehyde and amine through imine hydrolysis.

  6. Influence of various Activated Carbon based Electrode Materials in the Performance of Super Capacitor

    Science.gov (United States)

    Ajay, K. M.; Dinesh, M. N.

    2018-02-01

    Various activated carbon based electrode materials with different surface areas was prepared on stainless steel based refillable super capacitor model using spin coating. Bio Synthesized Activated Carbon (BSAC), Activated Carbon (AC) and Graphite powder are chosen as electrode materials in this paper. Electrode materials prepared using binder solution which is 6% by wt. polyvinylidene difluoride, 94% by wt. dimethyl fluoride. 3M concentrated KOH solution is used as aqueous electrolyte with PVDF thin film as separator. It is tested for electrochemical characterizations and material characterizations. It is observed that the Specific capacitance of Graphite, Biosynthesized active carbon and Commercially available activated carbon are 16.1F g-1, 53.4F g-1 and 107.6F g-1 respectively at 5mV s-1 scan rate.

  7. DFT study of Hg adsorption on M-substituted Pd(1 1 1) and PdM/γ-Al{sub 2}O{sub 3}(1 1 0) (M = Au, Ag, Cu) surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jiancheng; Yu, Huafeng [Key Laboratory of Coal Science and Technology, Ministry of Education and Shanxi Province, Taiyuan University of Technology, Taiyuan 030024 (China); Geng, Lu [College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan 030024 (China); Liu, Jianwen [National Supercomputing Center in Shenzhen, Shenzhen 518055 (China); Han, Lina, E-mail: hanlina@tyut.edu.cn [College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan 030024 (China); Chang, Liping [Key Laboratory of Coal Science and Technology, Ministry of Education and Shanxi Province, Taiyuan University of Technology, Taiyuan 030024 (China); Feng, Gang, E-mail: fengg.sshy@sinopec.com [Shanghai Research Institute of Petrochemical Technology SINOPEC, Shanghai 201208 (China); College of Chemistry, Nanchang University, Nanchang, Jiangxi 330031 (China); Ling, Lixia [Key Laboratory of Coal Science and Technology, Ministry of Education and Shanxi Province, Taiyuan University of Technology, Taiyuan 030024 (China)

    2015-11-15

    Graphical abstract: - Highlights: • M-substituted Pd surfaces show good Hg adsorption capacity at low Hg coverage. • γ-Al{sub 2}O{sub 3} can enhance the activity of bimetallic PdM for Hg adsorption. • Pd is the main active composition of PdM/γ-Al{sub 2}O{sub 3} sorbent for Hg adsorption. • Cu addition is a better than Au and Ag for the Pd-based Hg adsorbents. - Abstract: The adsorption of Hg{sub n} (n = 1–3) on the Au-, Ag-, Cu-substituted Pd(1 1 1) surfaces as well as the PdM/γ-Al{sub 2}O{sub 3}(1 1 0) (M = Au, Ag, Cu) surfaces has been investigated using spin-polarized density functional theory calculations. It is found that M-substituted Pd(1 1 1) surfaces show as good Hg adsorption capacity as the perfect Pd(1 1 1) at low Hg coverage, while the Hg adsorption capacity is only slightly weakened at high Hg coverage. On the basis of stepwise adsorption energies analysis, it is concluded that M-substituted Pd(1 1 1) surfaces can contribute to the binding of Hg atom on the surfaces at high Hg coverage. The electronic properties of the second metal atoms are the main factor contributes to the Hg adsorption capacity. Gas phase Pd{sub 2} shows better Hg adsorption capacity than Pd{sub 2}/γ-Al{sub 2}O{sub 3}, while PdM/γ-Al{sub 2}O{sub 3} can adsorb Hg more efficiently than bare PdM clusters. It suggests that the γ-Al{sub 2}O{sub 3} support can enhance the activity of PdM for Hg adsorption and reduces the activity of Pd{sub 2}. It is also found that Pd is the main active composition responsible for the interaction of mercury with the surface for PdM/γ-Al{sub 2}O{sub 3} sorbent. Taking Hg adsorption capacity and economic costs into account, Cu addition is a comparatively good candidate for Hg capture.

  8. General synthesis of noble metal (Au, Ag, Pd, Pt) nanocrystal modified MoS2 nanosheets and the enhanced catalytic activity of Pd-MoS2 for methanol oxidation

    Science.gov (United States)

    Yuwen, Lihui; Xu, Fei; Xue, Bing; Luo, Zhimin; Zhang, Qi; Bao, Biqing; Su, Shao; Weng, Lixing; Huang, Wei; Wang, Lianhui

    2014-05-01

    A general and facile method for water-dispersed noble metal (Au, Ag, Pd, Pt) nanocrystal modified MoS2 nanosheets (NM-MoS2 NSs) has been developed. By using sodium carboxymethyl cellulose as a stabilizer, well-dispersed NM-MoS2 NSs with homogeneously deposited noble metal nanocrystals (NM NCs) can be synthesized in aqueous solutions. Due to the transition from the semiconducting 2H phase to the metallic 1T phase, the chemically exfoliated MoS2 (ce-MoS2) NSs have improved electrochemical activity. The partially metallic nature of the ce-MoS2 NSs and the catalytic activity of the NM NCs synergistically make NM-MoS2 NSs a potential electrochemical catalyst. For the first time, Pd-MoS2 NSs were used as an electrocatalyst for methanol oxidation in alkaline media. The results showed that Pd-MoS2 NSs have enhanced catalytic activity with 2.8-fold anodic peak current mass density compared to a commercial Pd/C catalyst, suggesting potential for application in direct methanol fuel cells (DMFCs).A general and facile method for water-dispersed noble metal (Au, Ag, Pd, Pt) nanocrystal modified MoS2 nanosheets (NM-MoS2 NSs) has been developed. By using sodium carboxymethyl cellulose as a stabilizer, well-dispersed NM-MoS2 NSs with homogeneously deposited noble metal nanocrystals (NM NCs) can be synthesized in aqueous solutions. Due to the transition from the semiconducting 2H phase to the metallic 1T phase, the chemically exfoliated MoS2 (ce-MoS2) NSs have improved electrochemical activity. The partially metallic nature of the ce-MoS2 NSs and the catalytic activity of the NM NCs synergistically make NM-MoS2 NSs a potential electrochemical catalyst. For the first time, Pd-MoS2 NSs were used as an electrocatalyst for methanol oxidation in alkaline media. The results showed that Pd-MoS2 NSs have enhanced catalytic activity with 2.8-fold anodic peak current mass density compared to a commercial Pd/C catalyst, suggesting potential for application in direct methanol fuel cells (DMFCs

  9. Factors influencing voltammetric reduction of 5-nitroquinoline at boron-doped diamond electrodes

    Czech Academy of Sciences Publication Activity Database

    Vosáhlová, J.; Zavázalová, J.; Petrák, Václav; Schwarzová-Pecková, K.

    2016-01-01

    Roč. 147, č. 1 (2016), s. 21-29 ISSN 0026-9247 Institutional support: RVO:68378271 Keywords : voltammetry * boron-doped diamond electrode * boron concentration * reduction * electrochemistry Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 1.282, year: 2016

  10. Study of the influence of carbon on the negative lead-acid battery electrodes

    Czech Academy of Sciences Publication Activity Database

    Bača, P.; Micka, Karel; Křivík, P.; Tonar, K.; Tošer, P.

    2011-01-01

    Roč. 196, č. 8 (2011), s. 3988-3992 ISSN 0378-7753 Institutional research plan: CEZ:AV0Z40400503 Keywords : lead battery electrodes * doping with carbon * accelerated testing Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 4.951, year: 2011

  11. Influence of electrode impedance changes on the common-mode rejection ratio in bioimpedance measurements.

    Science.gov (United States)

    Petrova, G I

    1999-11-01

    Bioelectrical impedance in vivo measurements suffer from many potential sources of error due to the patient-instrument interface. The total common-mode rejection ratio (CMRR(T)) was investigated experimentally for three measurement channel circuit versions, including electrode-skin impedance imbalance. The first version was of the 'classical' type. The second one makes use of a differential filter at the input of the instrumentation amplifier. The third circuit was a frequency-converting structure, where the signal was demodulated before being amplified. The differential demodulator was based on synchronous sampling using floating capacitors. The experiments were accomplished with simulated imbalance of the real and imaginary parts of electrode-skin impedances. To reduce unwanted common-mode voltage, a differential accurately balanced current source was used. Considering an application in impedance cardiography, the experiments were carried out at a single frequency of 40 kHz. The results showed the advantage of the circuits using frequency conversion and differential input filter, rendering at least 15 dB higher CMRR(T). The most significant reduction of CMRR(T) resulted from imbalance of the capacitance component of voltage-sensing electrode impedances. The third circuit showed an unexpected behaviour of CMRR(T) improvement with higher imbalance of the electrode-skin impedance resistance component.

  12. Influence of Gate Dielectrics, Electrodes and Channel Width on OFET Characteristics

    Science.gov (United States)

    Liyana, V. P.; Stephania, A. M.; Shiju, K.; Predeep, P.

    2015-06-01

    Organic Field Effect Transistors (OFET) possess wide applications in large area electronics owing to their attractive features like easy fabrication process, light weight, flexibility, cost effectiveness etc. But instability, high operational voltages and low carrier mobility act as inhibitors to commercialization of OFETs and various approaches were tried on a regular basis so as to make it viable. In this work, Poly 3-hexylthiophene-2,5diyl (P3HT) based OFETs with bottom-contact top-gate configuration using Poly vinyl alcohol (PVA) and Poly (methyl methacrylate) (PMMA) as gate dielectrics, aluminium and copper as source-drain electrodes are investigated. An effort is made to compare the effect of these dielectric materials and electrodes on the performance of OFET. Also, an attempt has been made to optimize the channel width of the device. These devices are characterised with mobility (μ), threshold voltage (VT), on-off ratio (Ion/Ioff) and their comparative analysis is reported.

  13. Analysis of dispersed frequency response for ionic glasses: influence of electrode and nearly constant loss effects

    International Nuclear Information System (INIS)

    Macdonald, J Ross

    2005-01-01

    Analysis by D L Sidebottom of the dispersive frequency response of the real-part of the conductivity, σ'(ω), for many alkali phosphate and metaphosphate glasses, using a fitting model involving a 'universal dynamic response' power law with an exponent n and a constant-loss term, led to anomalous n behaviour that he explained as arising from variable constriction of the local cation conduction space. In order to obtain adequate fits, he eliminated from the data all low-frequency decreases of σ'(ω) below the dc plateau, ones actually associated with electrode effects. Such a cut-off does not, however, eliminate electrode effects possibly present in the high-frequency part of the data range. The results of the present detailed analysis and fitting of both synthetic data and several of his experimental data sets show unequivocally that his anomalous n behaviour arose from neglecting electrode effects. Their inclusion, with or without data cut-off in the fitting model, leads to the expected high-frequency slope value of n = 2/3 associated with bulk conduction, as required by recently published topological effective-dimension considerations for dielectric relaxation in conductive systems. Further, the effects of the inclusion in a full fitting model of series and possibly parallel complex constant-phase-element contributions, representing electrode and nearly constant loss effects, respectively, have been investigated in detail. Such composite models usually lead to best fitting of either the full or cut-off complex data when they include the semi-universal, topologically based K1 bulk model, one indirectly derived from the assumption of stretched-exponential temporal behaviour

  14. Study on the influence of the B4C layer thickness on the neutron flux and energy distribution shape in multi-electrode ionisation chamber.

    Science.gov (United States)

    Tymińska, K; Maciak, M; Ośko, J; Tulik, P; Zielczyński, M; Gryziński, M A

    2014-10-01

    A model of a multi-electrode ionisation chamber, with polypropylene electrodes coated with a thin layer of B4C was created within Monte Carlo N-Particle Transport Code (MCNPX) and Fluktuierende Kaskade (FLUKA) codes. The influence of the layer thickness on neutron absorption in B4C and on the neutron spectra in the consecutive intra-electrode gas volumes has been studied using the MCNPX and FLUKA codes. The results will be used for designing the new type of the ionisation chamber. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Influence of the implanted pulse generator as reference electrode in finite element model of monopolar deep brain stimulation.

    Science.gov (United States)

    Walckiers, Grégoire; Fuchs, Benjamin; Thiran, Jean-Philippe; Mosig, Juan R; Pollo, Claudio

    2010-01-30

    Electrical deep brain stimulation (DBS) is an efficient method to treat movement disorders. Many models of DBS, based mostly on finite elements, have recently been proposed to better understand the interaction between the electrical stimulation and the brain tissues. In monopolar DBS, clinically widely used, the implanted pulse generator (IPG) is used as reference electrode (RE). In this paper, the influence of the RE model of monopolar DBS is investigated. For that purpose, a finite element model of the full electric loop including the head, the neck and the superior chest is used. Head, neck and superior chest are made of simple structures such as parallelepipeds and cylinders. The tissues surrounding the electrode are accurately modelled from data provided by the diffusion tensor magnetic resonance imaging (DT-MRI). Three different configurations of RE are compared with a commonly used model of reduced size. The electrical impedance seen by the DBS system and the potential distribution are computed for each model. Moreover, axons are modelled to compute the area of tissue activated by stimulation. Results show that these indicators are influenced by the surface and position of the RE. The use of a RE model corresponding to the implanted device rather than the usually simplified model leads to an increase of the system impedance (+48%) and a reduction of the area of activated tissue (-15%). (c) 2009 Elsevier B.V. All rights reserved.

  16. An Influence of Parameters of Micro-Electrical Discharge Machining On Wear of Tool Electrode

    DEFF Research Database (Denmark)

    Puthumana, Govindan

    2017-01-01

    To achieve better precision of features generated using the micro-electrical dischargemachining (micro-EDM), there is a necessity to minimize the wear of the toolelectrode, because a change in the dimensions of the electrode is reflected directly orindirectly on the feature. This paper presents...... a novel modeling and analysis approachof the tool wear in micro-EDM using a systematic statistical method exemplifying theinfluences of capacitance, feed rate and voltage on the tool wear ratio. The associationbetween tool wear ratio and the input factors is comprehended by using main effectplots...

  17. Influence of the Oxygen Electrode Open Ratio and Electrolyte Evaporation on the Performance of Li-O2 Batteries.

    Science.gov (United States)

    Mohazabrad, Farhad; Wang, Fangzhou; Li, Xianglin

    2017-05-10

    This study experimentally investigates and numerically simulates the influence of the cathode electrode open ratio (ratio of oxygen-opening area to the total electrode surface area) on the performance of Li-O 2 batteries at various discharge current densities. At the current density of 0.1 mA/cm 2 , the maximum discharge capacity is achieved at 25% open ratio among the tested open ratios (0-100%). As the open ratio increases from 25% to 100%, the specific discharge capacity decreases from 995 to 397 mA h/g carbon . A similar trend is observed at 0.3 mA/cm 2 , while the maximum discharge capacity is obtained at 3% open ratio among the tested open ratios. The model that assumes the electrode is always fully saturated by the electrolyte does not obtain similar trends with experimental results, while the model that considers electrolyte loss by evaporation and the volume change of the solid obtains the same trend with experimental observations. The open ratio governs not only availability of oxygen but also the evaporation of the electrolyte and the contact resistance. The faster evaporation of the electrolyte at a higher open ratio can be the main reason for the decrease of the discharge capacity, especially when the open ratio is relatively high (above 25%). Meanwhile, the contact resistance of the battery, measured by the electrochemical impedance spectroscopy (EIS), increases from 3.97 to 7.02 Ω when the open ratio increased from 3% to 95%. The increase of the Ohmic overpotential, however, is negligible (on the order of millivolts) because of the low discharge and charge current rates (on the order of 0.1 mA).

  18. Nanotribology at single crystal electrodes: Influence of ionic adsorbates on friction forces studied with AFM

    Energy Technology Data Exchange (ETDEWEB)

    Hausen, Florian; Nielinger, Michael; Ernst, Siegfried [Institut fuer Physikalische und Theoretische Chemie, Universitaet Bonn, Roemerstrasse 164, D-53117 Bonn (Germany); Baltruschat, Helmut [Institut fuer Physikalische und Theoretische Chemie, Universitaet Bonn, Roemerstrasse 164, D-53117 Bonn (Germany)], E-mail: baltruschat@uni-bonn.de

    2008-09-01

    We present friction force measurements on Au(1 1 1) single crystal electrode surfaces performed under electrochemical conditions using an atomic force microscope (AFM). At monoatomic steps friction is increased in both scan directions. In 0.05 M sulfuric acid an increase of friction is observed with the increase of adsorbed sulfate. Friction force increases non-linearly with load. Cu UPD also increases friction in presence of sulfate. However, in presence of 4 x 10{sup -4} M chloride friction is much smaller for all deposited Cu coverages - ranging from a submonolayer up to bulk copper compared to the solution without chloride. After dissolution of bulk copper clusters deposited on Au(1 1 1) we observed an area with higher friction forces due to the formation of an alloy between gold and copper.

  19. 3D inversion of magnetic and electrical resistivity-induced polarization data for an epithermal Au-Ag and underlying porphyry deposit: A case study from British Columbia, Canada

    Science.gov (United States)

    Abbassi, B.; Huebert, J.; Liu, L.; Lee, B.; Cheng, L.; Richards, J. P.; Unsworth, M. J.; Oldenburg, D.

    2013-12-01

    The Newton property is an epithermal Au-Ag deposit containing precious metals in association with disseminated sulfide minerals such as pyrite. This type of deposit often shows variable geological patterns, so it is important to find fast and cost-efficient methods for their exploration. Aeromagnetic surveys and ground electrical resistivity-induced polarization methods were applied over the Newton property. From preliminary 3D inversion of ZTEM and aeromagnetic data, and joint 3D inversion of electrical resistivity-induced polarization data, we show that low-resistivity and high-chargeability regions are signatures of disseminated sulfide mineralization. Potassic alteration, characterized by hydrothermal biotite (now mostly chloritized) and magnetite is also present locally, and may be related to underlying porphyry-type mineralization. This type of alteration can be identified from its magnetic signature, but the occurrence of other magnetic formations in the deposit area made interpretations of magnetic data difficult. We show that filtering geological noises related to background magnetic anomalies is an essential step in focusing on potassic alteration zones. We used electrical resistivity and induced polarization chargeability models to remove the signals of barren magnetic zones to focus on the susceptibilities pertaining to deep potassic alterations. In order to test the credibility of these interpretations, extensive petrophysical measurements (magnetic susceptibility, electrical resistivity, and gamma ray spectra) were collected on drill-core samples. We show that potassic alteration can also be characterized accurately from high levels of potassium to thorium ratio (K/Th) in gamma ray spectrometric measurements, and that this correlation is stronger than the magnetic signal (likely because hydrothermal magnetite is variable in abundance). Therefore, we focused on magnetic susceptibility values correlated with high K/Th ratios in order to reduce the

  20. Influence of air flow parameters on nanosecond repetitively pulsed discharges in a pin-annular electrode configuration

    KAUST Repository

    Heitz, Sylvain A

    2016-03-16

    The effect of various air flow parameters on the plasma regimes of nanosecond repetitively pulsed (NRP) discharges is investigated at atmospheric pressure. The two electrodes are in a pin-annular configuration, transverse to the mean flow. The voltage pulses have amplitudes up to 15 kV, a duration of 10 ns and a repetition frequency ranging from 15 to 30 kHz. The NRP corona to NRP spark (C-S) regime transition and the NRP spark to NRP corona (S-C) regime transition are investigated for different steady and harmonically oscillating flows. First, the strong effect of a transverse flow on the C-S and S-C transitions, as reported in previous studies, is verified. Second, it is shown that the azimuthal flow imparted by a swirler does not affect the regime transition voltages. Finally, the influence of low frequency harmonic oscillations of the air flow, generated by a loudspeaker, is studied. A strong effect of frequency and amplitude of the incoming flow modulation on the NRP plasma regime is observed. Results are interpreted based on the cumulative effect of the NRP discharges and an analysis of the residence times of fluid particles in the inter-electrode region. © 2016 IOP Publishing Ltd.

  1. Insulation Coordination of Arcing Horns on HVDC Electrode Lines: Protection Performance Evaluation, Influence Factors and Improvement Method

    Directory of Open Access Journals (Sweden)

    Xiandong Li

    2018-02-01

    Full Text Available Arcing horns are widely used in high voltage overhead lines to protect insulator strings from being destroyed by the free burning arcs caused by lightening faults. In this paper, we focus on the insulation coordination of arcing horns on the electrode lines of a 5000 MW, ±800 kV high voltage direct current (HVDC system. The protection performance of arcing horns are determined by the characteristics of not only the external system but also the fault arc. Therefore, the behaviors and characteristics of long free burning arcs are investigated by the experiments at first. In order to evaluate the protection performance of arcing horns, the static stability criterion U-I characteristic method is introduced. The influence factors on the protection performance of arcing horns are analyzed theoretically. Finally, the improvement methods for the protection performance of arcing horns are proposed, and the diversified configuration strategy of arcing horns is recommended for cost saving.

  2. Influence of Gap Distance on Vacuum Arc Characteristics of Cup Type AMF Electrode in Vacuum Interrupters

    International Nuclear Information System (INIS)

    Cheng Shaoyong; Xiu Shixin; Wang Jimei; Shen Zhengchao

    2006-01-01

    The greenhouse effect of SF 6 is a great concern today. The development of high voltage vacuum circuit breakers becomes more important. The vacuum circuit breaker has minimum pollution to the environment. The vacuum interrupter is the key part of a vacuum circuit breaker. The interrupting characteristics in vacuum and arc-controlling technique are the main problems to be solved for a longer gap distance in developing high voltage vacuum interrupters. To understand the vacuum arc characteristics and provide effective technique to control vacuum arc in a long gap distance, the arc mode transition of a cup-type axial magnetic field electrode is observed by a high-speed charge coupled device (CCD) video camera under different gap distances while the arc voltage and arc current are recorded. The controlling ability of the axial magnetic field on vacuum arc obviously decreases when the gap distance is longer than 40 mm. The noise components and mean value of the arc voltage significantly increase. The effective method for controlling the vacuum arc characteristics is provided by long gap distances based on the test results. The test results can be used as a reference to develop high voltage and large capacity vacuum interrupters

  3. Influence of impurities on the H{sub 2}/H{sub 2}O/Ni/YSZ electrode

    Energy Technology Data Exchange (ETDEWEB)

    Hoegh, J.

    2005-05-15

    The kinetics of the SOFC anode or more specific the H{sub 2}/H{sub 2}O/Ni/SZ electrode (SZ=stabilized zirconia) is widely investigated, but there are large disagreements about the kinetics and mechanisms in the literature. It is reported that impurities from the electrode materials (Ni/SZ) segregate to the surface/interface/TPB (TPB=three phase boundary) and that these impurities have a negative influence on the kinetics. These impurities may be the explanation for the disagreements found in the literature. The purpose of this study is therefore to perform electrochemical measurements in a very clean system to avoid the effects of impurities. This is attempted by using high purity materials, lowering the operation temperature to prevent fast segregation of impurities and by limiting impurities from the environment. A simplified geometry of the real SOFC anode, which is a porous Ni/SZ composite, was studied. The simplified anode was made by pressing a Ni wire against a single crystal of stabilized zirconia. In spite of the efforts of making electrochemical measurements in a very clean system, impurities were still found on the surface of the electrode materials (Ni and SZ) after an electrochemical experiment. The impurities found on the SZ are believed to segregate from the bulk of SZ to the surface. Sulfur was found on the surface of the Ni, but its origin is unclear. A higher impurity level was detected on the surface of the Ni and SZ outside the contact area (between the Ni and YSZ) than inside the contact area. The initial smooth surface of the SZ had developed a hill and valley structure in the contact area after a heat treatment. Also, a ridge around the contact area on the SZ was seen. The polarization resistance at open circuit voltage (500 deg. C, 3% H20/H2) increased by a factor of 5-19 over 10-20 days before leveling out. The increase in polarization resistance is believed to be caused by: 1) Segregated impurities, 2) The built up of a ridge around the

  4. Space Charge Formation in XLPE - the Influence of Electrodes and Pre-conditioning

    DEFF Research Database (Denmark)

    Holbøll, Joachim T.; Henriksen, Mogens; Fleming, R.J.

    1999-01-01

    The composition of the inner and outer “semicon” shields in modern ac cables, and the temperature/pressure conditions under which the various manufacturing procedures are carried out, would be expected to influence space charge accumulation under dc stress significantly. However, few systematic i...... as vacuum-evaporated gold. The samples were also subjected to three different heating/pumping conditioning procedures....

  5. Influence of tributylphosphate (TBP) on the electrochemical reduction of uranium(6) on the mercury electrodes

    International Nuclear Information System (INIS)

    Wojdecka-Semkow, K.; Sobkowska, A.

    1979-01-01

    The influence of TBP on the reduction of uranium(6) in aqueous perchlorate solutions using D.C. polarography, cyclic voltammetry and square-wave polarography has been studied. It was found that the TBP concentration lower than 7 x 10 -5 M has no influence on the polarographic wave or voltammetric curve of uranium(6). The presence of TBP in the concentration range of 7 x 10 -5 to 2 x 10 -4 M has an influence on a height and potentials of waves and curves of uranium(6). At the concentration of TBP higher than 2 x 10 -4 M the parameters of the polarographic waves and the voltammetric curves of uranium(6) do not depend on the concentration of TBP. It can be useful in the determination of uranium in the presence of TBP. The square-wave polarography method cannot be used for determination of uranium in the presence of TBP because of the great influence of surface active agents on parameters of the uranium peaks. (author)

  6. Electrodeposition of lead on ITO electrode: influence of copper as an additive

    International Nuclear Information System (INIS)

    Avellaneda, Cesar O.; Napolitano, Marcos A.; Kaibara, Evandro K.; Bulhoes, Luis O.S.

    2005-01-01

    The reversible electrodeposition of metallic lead onto indium-tin oxide coated glass (ITO) was investigated and the influence of Cu(NO 3 ) 2 ·3H 2 O as additive was evaluated. The presence of Cu 2+ in the electrolytic solution produces a higher variation in the optical transmissivity. The optical response of the system changes from 85 to 10% relative to the ITO coated substrate. The kinetics of the electroreduction process of the Pb 2+ and Cu 2+ from the electrolytes has been determined by electrochemical impedance spectroscopy (EIS) at different electrodeposition potentials. This system may be a promising candidate for electrochromic materials

  7. Radiofrequency tissue ablation with cooled-tip electrodes:an experimental study in a bovine liver model on variables influencing lesion size

    Energy Technology Data Exchange (ETDEWEB)

    Han, Hyun Young [Eulgy Univ. Hospital, Seoul (Korea, Republic of); Lee, Jeong Min; Kim, Chong Soo [Chonbuk National Univ. Hospital, Chonju (Korea, Republic of)

    2001-03-01

    The purpose of this study was to determine the influence of various factors on the extent of thermal coagulation necrosis after radiofrequency (RF) tissue ablation using a cooled-tip electrode in bovine liver. RF ablation was induced by a monopolar 500 KHz-RF generator (CC-1; Radionics, Burlington, Mass., U.S.A.) and an 18-G cooled-tip with single or clustered electrodes. The ablation protocol involved a combination of varying current, ablation time, power output, gradual or abrupt increase of this out-put, and pulsed radiofrequency techniques. The maximum diameter of all thermal lesions which showed a color change was measured perpendicular to the electrode axis by two observers who reached their decisions by consensus. Twenty representative lesions were pathologically examined. With increasing current lesion diameter also increased, but above 1500 mA no further increase was induced. Extending the ablation time to 9 minutes for a single electrode and 15 minutes for a clustered electrode increased lesion diameter until a steady state was reached. Higher power levels caused larger lesions, but above 100 W no increase was observed. Ample exposure time coupled with a stepwise increase in power level induced a lesion larger than that resulting from an abrupt increase. Continuous pulsed RF with a high current led to increased coagulation necrosis diameter. These experimental findings may be useful thermotherapy. The data suggest that all involved factors significantly affect lesion size:if the factors are better understood, cancer thermotherapy can be better controlled.

  8. Influence of Nafion film on oxygen reduction reaction and hydrogen peroxide formation on Pt electrode for proton exchange membrane fuel cell

    International Nuclear Information System (INIS)

    Ohma, Atsushi; Fushinobu, Kazuyoshi; Okazaki, Ken

    2010-01-01

    The influence of Nafion film on ORR kinetics and H 2 O 2 formation on a Pt electrode was investigated using RRDE in 0.1 M HClO 4 . It was found that the Nafion-coated Pt system showed lower apparent ORR activity and more H 2 O 2 production than the bare Pt electrode system. From the temperature sensitivity, it was revealed that the apparent activation energies of ORR in the Nafion-coated Pt system were lower than the bare Pt electrode system, and the H 2 O 2 formation was suppressed with the increase of the temperature. In order to analyze the results furthermore, other systems (0.1/1.0 M, HClO 4 /CF 3 SO 3 H) with the bare Pt electrodes were also examined as references. It was exhibited that the ORR kinetic current, the H 2 O 2 formation, and the apparent activation energies of 1.0 M CF 3 SO 3 H system were close to those of the Nafion-coated Pt system. We concluded that the orientation of anion species of Nafion and CF 3 SO 3 H to the Pt surface via water molecules, as well as a fluorocarbon polymer network of Nafion, might block O 2 adsorption, resulting in the smaller effective surface area of the Pt electrode for ORR, the smaller ORR kinetic current, and the more H 2 O 2 production.

  9. Nanostructured Iron and Manganese Oxide Electrode Materials for Lithium Batteries: Influence of Chemical and Physical Properties on Electrochemistry

    Science.gov (United States)

    Durham, Jessica L.

    The widespread use of portable electronics and growing interest in electric and hybrid vehicles has generated a mass market for batteries with increased energy densities and enhanced electrochemical performance. In order to address a variety of applications, commercially fabricated secondary lithium-ion batteries employ transition metal oxide based electrodes, the most prominent of which include lithium nickel manganese cobalt oxide (LiNixMn yCo1-x-yO2), lithium iron phosphate (LiFePO4), and lithium manganese oxide (LiMn 2O4). Transition metal oxides are of particular interest as cathode materials due to their robust framework for lithium intercalation, potential for high energy density, and utilization of earth-abundant elements (i.e. iron and manganese) leading to decreased toxicity and cost-effective battery production on industrial scales. Specifically, this research focuses on MgFe2O4, AgxMn8O16, and AgFeO 2 transition metal oxides for use as electrode materials in lithium-based batteries. The electrode materials are prepared via co-precipitation, reflux, and hydrothermal methods and characterized by several techniques (XRD, SEM, BET, TGA, DSC, XPS, Raman, etc.). The low-temperature syntheses allowed for precise manipulation of structural, compositional, and/or functional properties of MgFe2O4, AgxMn8 O16, and AgFeO2 which have been shown to influence electrochemical behavior. In addition, advanced in situ and ex situ characterization techniques are employed to study the lithiation/de-lithiation process and establish valid redox mechanisms. With respect to both chemical and physical properties, the influence of MgFe2O4 particle size and morphology on electrochemical behavior was established using ex situ X-ray absorption spectroscopy (XAS) and transmission electron microscopy (TEM) imaging. Based on composition, tunneled AgxMn8O16 nanorods, prepared with distinct Ag+ contents and crystallite sizes, display dramatic differences in ion-transport kinetics due to

  10. Influence of Electrolyte Modulus on the Local Current Density at a Dendrite Tip on a Lithium Metal Electrode

    Energy Technology Data Exchange (ETDEWEB)

    Harry, KJ; Higa, K; Srinivasan, V; Balsara, NP

    2016-08-10

    Understanding and controlling the electrochemical deposition of lithium is imperative for the safe use of rechargeable batteries with a lithium metal anode. Solid block copolymer electrolyte membranes are known to enhance the stability of lithium metal anodes by mechanically suppressing the formation of lithium protrusions during battery charging. Time-resolved hard X-ray microtomography was used to monitor the internal structure of a symmetric lithium-polymer cell during galvanostatic polarization. The microtomography images were used to determine the local rate of lithium deposition, i.e. local current density, in the vicinity of a lithium globule growing through the electrolyte. Measurements of electrolyte displacement enabled estimation of local stresses in the electrolyte. At early times, the current density was maximized at the globule tip, as expected from simple current distribution arguments. At later times, the current density was maximized at the globule perimeter. We show that this phenomenon is related to the local stress fields that arise as the electrolyte is deformed. The local current density, normalized for the radius of curvature, decreases with increasing compressive stresses at the lithium-polymer interface. To our knowledge, our study provides the first direct measurement showing the influence of local mechanical stresses on the deposition kinetics at lithium metal electrodes.

  11. INFLUENCE OF TEMPERATURE ON THE CORROSION POTENTIAL OF THE 241-AN-102 MULTI PROBE CORROSION MONITORING SYSTEM SECONDARY REFERENCE ELECTRODES

    Energy Technology Data Exchange (ETDEWEB)

    EDGEMON GL; TAYLOR TM

    2008-09-30

    A test program using 241-AN-102 waste simulants and metallic secondary reference electrodes similar to those used on the 241-AN-102 MPCMS was performed to characterize the relationship between temperature and secondary reference electrode open-circuit corrosion potential. This program showed that the secondary reference electrodes can be used to make tank and tank steel corrosion potential measurements, but that a correction factor of approximately 2 mV per degree Celsius of temperature difference must be applied, where temperature difference is defined as the difference between tank temperature at the time of measurement and 30 C, the average tank temperature during the first several months of 241-AN-102 MPCMS operation (when the corrosion potentials of the secondary reference electrodes were being recorded relative to the primary reference electrodes).

  12. Changes in ganglion cell physiology during retinal degeneration influence excitability by prosthetic electrodes

    Science.gov (United States)

    Cho, Alice; Ratliff, Charles; Sampath, Alapakkam; Weiland, James

    2016-04-01

    Objective. Here we investigate ganglion cell physiology in healthy and degenerating retina to test its influence on threshold to electrical stimulation. Approach. Age-related Macular Degeneration and Retinitis Pigmentosa cause blindness via outer retinal degeneration. Inner retinal pathways that transmit visual information to the central brain remain intact, so direct electrical stimulation from prosthetic devices offers the possibility for visual restoration. Since inner retinal physiology changes during degeneration, we characterize physiological properties and responses to electrical stimulation in retinal ganglion cells (RGCs) of both wild type mice and the rd10 mouse model of retinal degeneration. Main results. Our aggregate results support previous observations that elevated thresholds characterize diseased retinas. However, a physiology-driven classification scheme reveals distinct sub-populations of ganglion cells with thresholds either normal or strongly elevated compared to wild-type. When these populations are combined, only a weakly elevated threshold with large variance is observed. The cells with normal threshold are more depolarized at rest and exhibit periodic oscillations. Significance. During degeneration, physiological changes in RGCs affect the threshold stimulation currents required to evoke action potentials.

  13. Experimental Investigation Nano Particles Influence in NPMEDM to Machine Inconel 800 with Electrolyte Copper Electrode

    Science.gov (United States)

    Karunakaran, K.; Chandrasekaran, M.

    2017-05-01

    The recent technology of machining hard materials is Powder mix dielectric electrical Discharge Machining (PMEDM). This research investigates nano sized (about 5Nm) powders influence in machining Inconel 800 nickel based super alloy. This work is motivated for a practical need for a manufacturing industry, which processes various kinds of jobs of Inconel 800 material. The conventional EDM machining also considered for investigation for the measure of Nano powders performances. The aluminum, silicon and multi walled Carbon Nano tubes powders were considered in this investigation along with pulse on time, pulse of time and input current to analyze and optimize the responses of Material Removal Rate, Tool Wear Rate and surface roughness. The Taguchi general Full Factorial Design was used to design the experiments. The most advance equipments employed in conducting experiments and measuring equipments to improve the accuracy of the result. The MWCNT powder mix was out performs than other powders which reduce 22% to 50% of the tool wear rate, gives the surface roughness reduction from 29.62% to 41.64% and improved MRR 42.91% to 53.51% than conventional EDM.

  14. Influence of insulators adjacent to the collecting electrode in a proportional counter

    International Nuclear Information System (INIS)

    Srdoc, D.

    1977-01-01

    At least a part of the anode in a proportional counter is surrounded by insulating material, usually at both ends of the central wire. In some cases, such as the spherical anode counter, a substantial fraction of anode surface is in contact with insulating material. It was of interest to investigate the influence of insulators on the counter performance. The results of testing and measurements described show that the presence of insulating material close to the anode brings about transient phenomena, which are difficult to predict and interpret. The general conclusion is that the gas multiplication factor depends on the counting rate, the avalanche size, and the number of pulses per unit anode length per unit time. Namely, it was observed that transient phenomena in general are much more pronounced when a relatively narrow beam of soft x rays hits a limited section of the anode as opposed to the exposure of the whole counter to a 60 Co source. Whereas it is obvious that transients are caused by the charge buildup on the insulator surface, more research is necessary to explain the observed phenomena. Also, it can be concluded that such counters have a limited application caused by inherent instability of gas gain

  15. PEDOT(PSS) as Solid Contact for Ion-Selective Electrodes: The Influence of the PEDOT(PSS) Film Thickness on the Equilibration Times.

    Science.gov (United States)

    Guzinski, Marcin; Jarvis, Jennifer M; Perez, Felio; Pendley, Bradford D; Lindner, Ernő; De Marco, Roland; Crespo, Gaston A; Acres, Robert G; Walker, Raymart; Bishop, Josiah

    2017-03-21

    To understand the rate determining processes during the equilibration of poly(3,4-ethylenedioxythiophene):polystyrenesulfonate-based (PEDOT(PSS)-based) solid contact (SC) ion-selective electrodes (ISEs), the surfaces of Pt, Au, and GC electrodes were coated with 0.1, 1.0, 2.0, and 4.0 μm thick galvanostatically deposited PEDOT(PSS) films. Next, potential vs time transients were recorded with these electrodes, with and without an additional potassium ion-selective membrane (ISM) coating, following their first contact with 0.1 M KCl solutions. The transients were significantly different when the multilayered sensor structures were assembled on Au or GC compared to Pt. The differences in the rate of equilibration were interpreted as a consequence of differences in the hydrophilicity of PEDOT(PSS) in contact with the substrate electrode surfaces based on X-ray photoelectron spectroscopy (XPS) and synchrotron radiation-XPS (SR-XPS) analysis of 10-100 nm thick PEDOT(PSS) films. The influence of the layer thickness of the electrochemically deposited PEDOT(PSS)-films on the hydrophilicity of these films has been documented by contact angle measurements over PEDOT(PSS)-coated Au, GC, and Pt electrode surfaces. This study demonstrates that it is possible to minimize the equilibration (conditioning) time of SC ISEs with aqueous solutions before usage by optimizing the thickness of the SC layer with a controlled ISM thickness. PEDOT(PSS)-coated Au and GC electrodes exhibit a significant negative potential drift during their equilibration in an aqueous solution. By coating the PEDOT(PSS) surface with an ISM, the negative potential drift is compensated by a positive potential drift related to the hydration of the ISM and activity changes at the PEDOT(PSS)|ISM interface. The potential drifts related to activity changes in the ISM have been determined by a novel adaptation of the "sandwich membrane" method.

  16. Influence of phosphate buffer and proteins on the potentiometric response of a polymeric membrane-based solid-contact Pb(II) ion-selective electrode

    DEFF Research Database (Denmark)

    Joon, Narender Kumar; He, Ning; Wagner, Michal

    2017-01-01

    In this work, the influence of phosphate buffer and proteins on the potentiometric response of a polymeric membrane-based solid-contact Pb2+-selective electrode (Pb2+-ISE) was studied. The effects of bovine serum albumin (BSA) adsorption at the surface of the ion-selective membrane combined...... with electrode conditioning in phosphate-buffered saline (PBS) solution was elucidated by potentiometry and electrochemical impedance spectroscopy. The adsorbed BSA at the surface of the Pb2+-ISE slightly lowered the detection limit but did not influence the selectivity of the Pb2+-ISE towards the interfering...... dm–3 PBS + 1 mg/ml BSA it was possible to extend the linear response range of the Pb2+-ISE towards lower analyte concentrations. The utilization of this conditioning procedure was validated by determination of Pb2+ concentrations down to ca 20 ppb in aqueous samples by Pb2+-ISEs and by comparing...

  17. Influence of electrodes on the 448 kHz electric currents created by radiofrequency: A finite element study.

    Science.gov (United States)

    Spottorno, J; Gonzalez de Vega, C; Buenaventura, M; Hernando, A

    2017-01-01

    Radiofrequency is a technology used in physical rehabilitation by physicians and physiotherapists for more than fifteen years, although there exist doubts on how it works. Indiba is a particular method that applies a voltage difference of 448 KHz between two electrodes, creating an electric current between them. These electrodes are an active one that is placed on different areas of the body and a passive one that is left on the same position during the treatment. There are two different types of active electrodes: the capacitive one and the resistive one. In this paper, it has been studied how the different electrodes affect the current density inside the body and thus how they affect the efficacy of the treatment. It shows how finite element calculations should help physicians in order to better understand its behavior and improve the treatments.

  18. Radiofrequency Energy and Electrode Proximity Influences Stereoelectroencephalography-Guided Radiofrequency Thermocoagulation Lesion Size: An In Vitro Study with Clinical Correlation.

    Science.gov (United States)

    Staudt, Michael D; Maturu, Sarita; Miller, Jonathan P

    2018-02-16

    Radiofrequency thermocoagulation of epileptogenic foci via stereoelectroencephalography (SEEG) electrodes has been suggested as a treatment for medically intractable epilepsy, but reported outcomes have been suboptimal, possibly because lesions generated using conventional high-energy radiofrequency parameters are relatively small. To describe a technique of delivering low energy across separate SEEG electrodes in order to create large confluent radiofrequency lesions. The size and configuration of radiofrequency lesions using different radiofrequency intensity and interelectrode distance was assessed in egg whites. Magnetic resonance images (MRI) from 3 patients who had undergone radiofrequency lesion creation were evaluated to determine the contribution of lesion intensity and electrode separation on lesion size. Electroencephalography, MRI, and clinical data were assessed before and after lesion creation. Both in Vitro and in Vivo analysis revealed that less energy paradoxically produced larger lesions, with the largest possible lesions produced when radiofrequency power was applied for long duration at less than 3 W. Linear separation of electrodes also contributed to lesion size, with largest lesions produced when electrodes were separated by a linear distance of between 5 and 12 mm. Clinical lesions produced using these parameters were large and resulted in improvement in interictal and ictal activity. Radiofrequency lesions produced using low-energy delivery between SEEG electrodes in close proximity can produce a large lesion. These findings might have advantages for treatment of focal epilepsy.

  19. Influence of ITO-Silver Wire Electrode Structure on the Performance of Single-Crystal Silicon Solar Cells

    Directory of Open Access Journals (Sweden)

    Wern-Dare Jheng

    2012-01-01

    Full Text Available This study aimed to explore the effect of various electrode forms on single-crystal silicon solar cells by changing their front and back electrode structures. The high light penetration depth of the Indium Tin Oxide (ITO and the high conductivity of the silver wire that were coated on the single crystal silicon solar cells increased photoelectron export, thus increasing the efficiency of the solar cell. The experiment utilized a sol-gel solution containing phosphorus that was spin coated on single-crystal silicon wafers; this phosphorus also served as a phosphorus diffusion source. A p-n junction was formed after annealing at high temperature, and the substrate was coated with silver wires and ITO films of various structures to produce the electrodes. This study proposed that applying a heat treatment to the aluminum of back electrodes would result in a higher efficiency for single-crystal silicon solar cells, whereas single-crystal silicon solar cells containing front electrodes with ITO film coated with silver wires would result in efficiencies that are higher than those achieved using pure ITO thin-film electrodes.

  20. Influence of the inter-electrode gap on the cathode sheath characteristics (voltage drop across it and its thickness)

    Science.gov (United States)

    Lisovskiy, V. A.; Artushenko, K. P.; Yegorenkov, V. D.

    2017-05-01

    This paper is devoted to studying how the inter-electrode distance affects the voltage drop across electrodes, the cathode sheath thickness, and the axial distribution of plasma parameters. The experiment demonstrates the simultaneous growth of both the voltage drop across the electrodes and the cathode sheath thickness when on increasing the gap the anode is moved away from the cathode while remaining in the negative glow. This effect is most clearly pronounced under low gas pressure and high current values when the negative glow length is large. The discharge axial structure dynamics is studied with the Langmuir probe technique and with the OOPIC Pro code. The inter-electrode gap growth with the current fixed is found to be accompanied by the plasma concentration increase in the negative glow. The positive plasma potential is shown to cause the current to the grounded anode to be transported by fast electrons accelerated in the cathode sheath. Moving the anode away from the cathode through the negative glow weakens the flow of fast electrons coming to the anode, thus decreasing the discharge current. In order to restore the discharge current, one has to increase the voltage across the electrodes, leading to the cathode sheath thickness increase and the plasma concentration growth in the negative glow.

  1. Influence of the oxygen electrode and inter-diffusion barrier on the degradation of solid oxide electrolysis cells

    DEFF Research Database (Denmark)

    Hjalmarsson, Per; Sun, Xiufu; Liu, Yi-Lin

    2013-01-01

    -diffusion barrier sandwiched between the YSZ electrolyte and an LSCF:CGO oxygen electrode. Impedance Spectroscopy was used during the tests to diagnose the change in electrochemical response of the different components of the SOECs. The results showed a significantly lower degradation rate for the cell with an LSCF......Two Solid Oxide Electrolysis Cells (SOECs) with different oxygen electrodes have been tested in galvanostatic tests carried out at −1.5 Acm−2 and 800 °C converting 60% of a 50:50% mixture of H2O and CO2 (co-electrolysis). One of the cells had an LSM:YSZ oxygen electrode. The other had an CGO inter...

  2. The Influence of Titania Electrode Modification with Lanthanide Ions Containing Thin Layer on the Performance of Dye-Sensitized Solar Cells

    Directory of Open Access Journals (Sweden)

    Maciej Zalas

    2012-01-01

    Full Text Available The lanthanide and scandium groups ions (except Pm and Ac have been used as dopants of TiO2 film in dye-sensitized solar cells. The X-ray diffraction spectra show that the modification has no influence on the structure of the electrode; however, the diffuse reflectance UV-Vis measurements exhibit significant changes in the electronic properties of modified electrodes. The appearance of energy barrier preventing photoexcited electron back-transfer was confirmed for Sc, Ce, Sm, Tb, Ho, Tm, and Lu modified cells. The best photoconversion performance of 8.88 and 8.80% was found for samples modified with Ce and Yb, respectively, and it was greater by 31.4 and 30.2% than that of a unmodified cell.

  3. Modeling and evaluation of the influence of micro-EDM sparking state settings on the tool electrode wear behavior

    DEFF Research Database (Denmark)

    Puthumana, Govindan

    2017-01-01

    materials characterized by considerable wear ofthe tool used for material removal. This paper presents an investigation involving modeling and estimation of the effect of settings for generation of discharges in stable conditions of micro-EDM on the phenomenon of tool electrode wear. A stable sparking...... a condition for the minimum tool wear for this micro-EDM process configuration....

  4. Influences of Mg Doping on the Electrochemical Performance of TiO2 Nanodots Based Biosensor Electrodes

    Directory of Open Access Journals (Sweden)

    M. S. H. Al-Furjan

    2014-01-01

    Full Text Available Electrochemical biosensors are essential for health monitors to help in diagnosis and detection of diseases. Enzyme adsorptions on biosensor electrodes and direct electron transfer between them have been recognized as key factors to affect biosensor performance. TiO2 has a good protein adsorption ability and facilitates having more enzyme adsorption and better electron transfer. In this work, Mg ions are introduced into TiO2 nanodots in order to further improve electrode performance because Mg ions are considered to have good affinity with proteins or enzymes. Mg doped TiO2 nanodots on Ti substrates were prepared by spin-coating and calcining. The effects of Mg doping on the nanodots morphology and performance of the electrodes were investigated. The density and size of TiO2 nanodots were obviously changed with Mg doping. The sensitivity of 2% Mg doped TiO2 nanodots based biosensor electrode increased to 1377.64 from 897.8 µA mM−1 cm−2 and its KMapp decreases to 0.83 from 1.27 mM, implying that the enzyme achieves higher catalytic efficiency due to better affinity of the enzyme with the Mg doped TiO2. The present work could provide an alternative to improve biosensor performances.

  5. Stimulation and recording electrodes for neural prostheses

    CERN Document Server

    Pour Aryan, Naser; Rothermel, Albrecht

    2015-01-01

    This book provides readers with basic principles of the electrochemistry of the electrodes used in modern, implantable neural prostheses. The authors discuss the boundaries and conditions in which the electrodes continue to function properly for long time spans, which are required when designing neural stimulator devices for long-term in vivo applications. Two kinds of electrode materials, titanium nitride and iridium are discussed extensively, both qualitatively and quantitatively. The influence of the counter electrode on the safety margins and electrode lifetime in a two electrode system is explained. Electrode modeling is handled in a final chapter.

  6. pH matters: The influence of the catalyst ink on the oxygen reduction activity determined in thin film rotating disk electrode measurements

    Science.gov (United States)

    Inaba, Masanori; Quinson, Jonathan; Arenz, Matthias

    2017-06-01

    We investigated the influence of the ink properties of proton exchange membrane fuel cell (PEMFC) catalysts on the oxygen reduction reaction (ORR) activity determined in thin film rotating disk electrode (TF-RDE) measurements. It was found that the adaption of a previously reported ink recipe to home-made catalysts does not lead to satisfying results, although reported work could be reproduced using commercial catalyst samples. It is demonstrated that the pH of the catalyst ink, which has not been addressed in previous TF-RDE studies, is an important parameter that needs to be carefully controlled to determine the intrinsic ORR activity of high surface area catalysts.

  7. Treatment of highly concentrated tannery wastewater using electrocoagulation: Influence of the quality of aluminium used for the electrode

    Energy Technology Data Exchange (ETDEWEB)

    Elabbas, S.; Ouazzani, N.; Mandi, L. [Laboratoire d’Hydrobiologie, Ecotoxicologie et Assainissement (LHEA, URAC 33), Faculté de Sciences Semlalia, BP 2390, Université Cadi Ayyad, Marrakech (Morocco); Centre National d’Etude et de Recherche sur l’Eau et l’Energie (CNEREE), Université Cadi Ayyad, BP 511, Marrakech (Morocco); Berrekhis, F. [Equipe de Physico-chimie des Matériaux, Ecole Normale Supérieure, Université Cadi Ayyad, BP 2400, 40000 Marrakech (Morocco); Perdicakis, M. [Laboratoire de Chimie Physique et Microbiologie pour l’Environnement (LCPME) UMR 7564, Université de Lorraine—CNRS, 405 rue de Vandoeuvre, F-54602 Villers-lès Nancy Cedex (France); Pontvianne, S.; Pons, M-N.; Lapicque, F. [Laboratoire Réactions et Génie des Procédés (LRGP) UMR 7274, CNRS, Université de Lorraine, 1 rue Grandville, BP 20451, 54001 Nancy cedex (France); Leclerc, J-P, E-mail: jean-pierre.leclerc@univ-lorraine.fr [Laboratoire Réactions et Génie des Procédés (LRGP) UMR 7274, CNRS, Université de Lorraine, 1 rue Grandville, BP 20451, 54001 Nancy cedex (France)

    2016-12-05

    Highlights: • COD and Cr(III) species can be simultaneously removed by electrocoagulation. • Cu-containing Al alloy is more efficient than pure Al as electrodes. • Dilution of too concentrated tannery wastewater is required for efficient treatment. - Abstract: This paper deals with the ability of electrocoagulation (EC) to remove simultaneously COD and chromium from a real chrome tanning wastewater in a batch stirred electro-coagulation cell provided with two aluminium-based electrodes (aluminium/copper/magnesium alloy and pure aluminium). Effects of operating time, current density and initial concentration of Cr(III) and COD have been investigated. The concentrations of pollutants have been successfully reduced to environmentally acceptable levels even if the concentrated effluent requires a long time of treatment of around 6 h with a 400 A/m{sup 2} current density. The aluminium alloy was found to be more efficient than pure aluminium for removal of COD and chromium. Dilution of the waste has been tested for treatment: high abatement levels could be obtained with shorter time of treatment and lower current densities. Energy consumption of the electrocoagulation process was also discussed. The dilution by half of the concentrated waste leads to a higher abatement performance of both COD and chromium with the best energy efficiency.

  8. Magnetohydrodynamic electrode

    International Nuclear Information System (INIS)

    1980-01-01

    The object of the invention is the provision of a material capable of withstanding a high-temperature, corrosive and erosive environment for use as a ceramic-metal composite electrode current collector in the channel of a magnetohydrodynamic generator. (U.K.)

  9. The influence of the synthesis method of Ti/RuO{sub 2} electrodes on their stability and catalytic activity for electrochemical oxidation of the pesticide carbaryl

    Energy Technology Data Exchange (ETDEWEB)

    Santos, T.É.S. [Laboratório de Eletroquímica e Nanotecnologia, Instituto de Tecnologia e Pesquisa (ITP)/Programa de Pós-Graduação em Engenharia de Processos, Universidade Tiradentes, 49032–490 Aracaju, SE (Brazil); Silva, R.S. [Laboratório de Materiais Cerâmicos Avançados, Departamento de Física, Universidade Federal de Sergipe, 49.100-000 São Cristóvão, SE (Brazil); Carlesi Jara, C. [Escuela de Ingeniería Química, Pontificia Universidad Católica de Valparaíso, Av. Brasil No 2147, 2362804 Valparaíso (Chile); Eguiluz, K.I.B. [Laboratório de Eletroquímica e Nanotecnologia, Instituto de Tecnologia e Pesquisa (ITP)/Programa de Pós-Graduação em Engenharia de Processos, Universidade Tiradentes, 49032–490 Aracaju, SE (Brazil); Salazar-Banda, G.R., E-mail: gianrsb@gmail.com [Laboratório de Eletroquímica e Nanotecnologia, Instituto de Tecnologia e Pesquisa (ITP)/Programa de Pós-Graduação em Engenharia de Processos, Universidade Tiradentes, 49032–490 Aracaju, SE (Brazil)

    2014-11-14

    In this study, we developed dimensionally stable anodes of titanium covered with ruthenium oxides (Ti/RuO{sub 2}) using sol–gel, Pechini and ionic liquid (IL) methodologies. The electrochemical efficiency of these electrodes was then evaluated regarding electrochemical degradation of the pesticide carbaryl. The UV–visible spectroscopy measurements showed that the electrodes obtained by the IL and Pechini methods were more effective at pesticide degradation compared with the sol–gel electrode, especially at high current density values. Carbaryl degradation after 2 h of electrolysis at 30 mA cm{sup −2} was 96.4% and 95.5% for the electrodes obtained by the IL and Pechini methods, respectively, while the degradation was 65.0% for the electrodes obtained by the sol–gel method. Additionally, the electrodes prepared by the IL and Pechini methods showed greater physical and electrochemical stability when compared to electrodes obtained by the sol–gel method. Electrodes prepared by the IL method with a few covering layers (three) achieved an elevated and constant area in a more efficient way than electrodes prepared by the Pechini and sol–gel methods. This fact can be attributed to the higher viscosity of the ionic liquid-based precursor solution, which transfers a higher amount of Ru in one single layer, compared to the other methods studied, thus reducing the time for synthesis, the number of calcination steps and the production costs of electrodes. - Highlights: • We developed dimensionally stable anodes containing ruthenium oxides. • Sol–gel, Pechini and ionic liquid methodologies were used. • The ionic liquid method covers the surfaces more efficiently and with few layers. • The proposed method reduces the time and production cost for synthesis of electrodes. • The electrodes synthesized present high stability and pesticide degradation activity.

  10. The influence of the synthesis method of Ti/RuO2 electrodes on their stability and catalytic activity for electrochemical oxidation of the pesticide carbaryl

    International Nuclear Information System (INIS)

    Santos, T.É.S.; Silva, R.S.; Carlesi Jara, C.; Eguiluz, K.I.B.; Salazar-Banda, G.R.

    2014-01-01

    In this study, we developed dimensionally stable anodes of titanium covered with ruthenium oxides (Ti/RuO 2 ) using sol–gel, Pechini and ionic liquid (IL) methodologies. The electrochemical efficiency of these electrodes was then evaluated regarding electrochemical degradation of the pesticide carbaryl. The UV–visible spectroscopy measurements showed that the electrodes obtained by the IL and Pechini methods were more effective at pesticide degradation compared with the sol–gel electrode, especially at high current density values. Carbaryl degradation after 2 h of electrolysis at 30 mA cm −2 was 96.4% and 95.5% for the electrodes obtained by the IL and Pechini methods, respectively, while the degradation was 65.0% for the electrodes obtained by the sol–gel method. Additionally, the electrodes prepared by the IL and Pechini methods showed greater physical and electrochemical stability when compared to electrodes obtained by the sol–gel method. Electrodes prepared by the IL method with a few covering layers (three) achieved an elevated and constant area in a more efficient way than electrodes prepared by the Pechini and sol–gel methods. This fact can be attributed to the higher viscosity of the ionic liquid-based precursor solution, which transfers a higher amount of Ru in one single layer, compared to the other methods studied, thus reducing the time for synthesis, the number of calcination steps and the production costs of electrodes. - Highlights: • We developed dimensionally stable anodes containing ruthenium oxides. • Sol–gel, Pechini and ionic liquid methodologies were used. • The ionic liquid method covers the surfaces more efficiently and with few layers. • The proposed method reduces the time and production cost for synthesis of electrodes. • The electrodes synthesized present high stability and pesticide degradation activity

  11. Influence of Surface Charge/Potential of a Gold Electrode on the Adsorptive/Desorptive Behaviour of Fibrinogen

    International Nuclear Information System (INIS)

    Dargahi, Mahdi; Konkov, Evgeny; Omanovic, Sasha

    2015-01-01

    Highlights: • Adsorptive/desorptive behavior of fibrinogen (FG) on an electrochemically-polarized gold substrate is reported. • The adsorption affinity of FG (afFG) is constant on a negatively-charged substrate surface. • The afFG increases linearly with an increase in positive substrate surface charge. • The FG adsorption kinetics is strongly dependant on substrate surface charge. • The adsorbed FG layer can be desorbed by electrochemical evolution of hydrogen and oxygen. - Abstract: The effect of gold substrate surface charge (potential) on adsorptive/desorptive behaviour of fibrinogen (FG) was studied by employing differential capacitance (DC) and polarization modulated infrared reflection absorption spectroscopy (PM-IRRAS), in terms of FG adsorption thermodynamics, kinetics, and desorption kinetics. The gold substrate surface charge was modulated in-situ within the electrochemical double-layer region by means of electrochemical potentiostatic polarization in a FG-containing electrolyte, thus avoiding the interference of other physico-chemical properties of the gold surface on FG’s interfacial behaviour. The FG adsorption equilibrium was modeled using the Langmuir isotherm. Highly negative values of apparent Gibbs free energy of adsorption (ranging from from −52.1 ± 0.4 to −55.8 ± 0.8 kJ mol −1 , depending on the FG adsorption potential) indicated a highly spontaneous and strong adsorption of FG onto the gold surface. The apparent Gibbs free energy of adsorption was found to be independent of surface charge when the surface was negatively charged. However, when the gold surface was positively charged, the apparent Gibbs free energy of adsorption exhibited a pronounced linear relationship with the surface charge, shifting to more negative values with an increase in positive electrode potential. The adsorption kinetics of FG was also found to be dependent on gold surface charge in a similar manner to the apparent Gibbs free energy of adsorption

  12. Different influences of hematocrit on the results of two Point-Of-Care platelet function tests, the VerifyNow assay and multiple electrode platelet aggregometry.

    Science.gov (United States)

    Kim, Yun Gi; Suh, Jung-Won; Park, Jin Joo; Oh, Il-Young; Yoon, Chang-Hwan; Cho, Young-Seok; Youn, Tae-Jin; Chae, In-Ho; Choi, Dong-Ju

    2014-01-01

    Previous studies have reported a considerable association between the VerifyNow (Accumetrics, San Diego, CA, USA) P2Y12 assay results and hematocrit. No reports, however, have described an association between the multiple electrode platelet aggregometry (MEA; Dynabyte, Munich, Germany) adenosine diphosphate (ADP) assay results and hematocrit. This study was conducted to evaluate the influence of hematocrit on the results of 2 different point-of-care platelet function tests. A total of 462 consecutive patients who were undergoing percutaneous coronary intervention were enrolled. Platelet function was evaluated with both the VerifyNow P2Y12 and MEA ADP assays. Anemic patients (n = 152, 32.9%) demonstrated a significantly higher rate of cardiac death, myocardial infarction, and stroke (5.3% vs. 2.3%, p = 0.046) during the follow-up (median: 18.8 months). Although the VerifyNow P2Y12 assay results demonstrated a significant inverse correlation with hematocrit (r = -0.409, phematocrit (r = 0.039, p = 0.401). In the multivariate analysis, anemia was an independent predictor of high on-treatment platelet reactivity, defined as a VerifyNow P2Y12 reaction unit level of ≥252.5 (odds ratio = 2.21, 95% confidence interval = 1.39-3.52; p = 0.001). Importantly, this association was independent of an intrinsic change in platelet reactivity as measured by the MEA ADP assay. Adjusting for the influence of hematocrit improved the strength of the correlation between the VerifyNow P2Y12 and MEA ADP assay results. Hematocrit significantly influenced the VerifyNow P2Y12 assay results, a phenomenon that was presumably in-vitro. Hematocrit level should therefore be considered when interpreting results of the VerifyNow P2Y12 assay.

  13. Formation and Diffusion of Metal Impurities in Perovskite Solar Cell Material CH3NH3PbI3: Implications on Solar Cell Degradation and Choice of Electrode.

    Science.gov (United States)

    Ming, Wenmei; Yang, Dongwen; Li, Tianshu; Zhang, Lijun; Du, Mao-Hua

    2018-02-01

    Solar cells based on methylammonium lead triiodide (MAPbI 3 ) have shown remarkable progress in recent years and have demonstrated efficiencies greater than 20%. However, the long-term stability of MAPbI 3 -based solar cells has yet to be achieved. Besides the well-known chemical and thermal instabilities, significant native ion migration in lead halide perovskites leads to current-voltage hysteresis and photoinduced phase segregation. Recently, it is further revealed that, despite having excellent chemical stability, the Au electrode can cause serious solar cell degradation due to Au diffusion into MAPbI 3 . In addition to Au, many other metals have been used as electrodes in MAPbI 3 solar cells. However, how the external metal impurities introduced by electrodes affect the long-term stability of MAPbI 3 solar cells has rarely been studied. A comprehensive study of formation energetics and diffusion dynamics of a number of noble and transition metal impurities (Au, Ag, Cu, Cr, Mo, W, Co, Ni, Pd) in MAPbI 3 based on first-principles calculations is reported herein. The results uncover important general trends of impurity formation and diffusion in MAPbI 3 and provide useful guidance for identifying the optimal metal electrodes that do not introduce electrically active impurity defects in MAPbI 3 while having low resistivities and suitable work functions for carrier extraction.

  14. Influence of two-electrode montages on the level-specific (LS) CE-Chirp auditory brainstem response (ABR) at multiple intensity levels.

    Science.gov (United States)

    Dzulkarnain, Ahmad Aidil Arafat; Noor Ibrahim, Siti Hajra Mu'minah; Anuar, Nur Farah Aida; Abdullah, Siti Aisyah; Tengku Zam Zam, Tengku Zulaila Hasma; Rahmat, Sarah; Mohd Ruzai, Muhammad Amar

    2017-10-01

    To investigate the influence of two different electrode montages (ipsilateral: reference to mastoid and vertical: reference to nape of neck) to the ABR results recorded using a level-specific (LS)-CE-Chirp® in normally hearing subjects at multiple intensities levels. Quasi-experimental and repeated measure study designs were applied in this study. Two different stopping criteria were used, (1) a fixed-signal averaging 4000 sweeps and, (2) a minimum quality indicator of Fmp = 3.1 with a minimum of 800 sweeps. Twenty-nine normally hearing adults (18 females, 11 male) participated. Wave V amplitudes were significantly larger in the LS CE-Chirp® recorded from the vertical montage than the ipsilateral montage. Waves I and III amplitudes were significantly larger from the ipsilateral LS CE-Chirp® than from the other montages and stimulus combinations. The differences in the quality of the ABR recording between the vertical and ipsilateral montages were marginal. Overall, the result suggested that the vertical LS CE-Chirp® ABR had a high potential for a threshold-seeking application, because it produced a higher wave V amplitude. The Ipsilateral LS CE-Chirp® ABR, on the other hand, might also have a high potential for the site of lesion application, because it produced larger waves I and III amplitudes.

  15. The influence of local glucose oxidase activity on the potential/current distribution on stainless steel: A study by the wire beam electrode method

    International Nuclear Information System (INIS)

    Wang Wei; Zhang Xia; Wang Jia

    2009-01-01

    The wire beam electrode (WBE) method was first used to study the activity of local glucose oxidase (GOD) on stainless steel surface in seawater. Glucose oxidase was immobilized in calcium alginate gel capsules, which were embedded in a layer of artificial biofilm (calcium alginate gel) on the WBE surface. The potential/current distributions on the WBE surface were mapped using a newly developed device for the WBE method in our lab. The results demonstrated that the catalysis of H 2 O 2 formation by GOD can produce local noble potential peaks and cathodic current zones on the stainless steel surface. An interesting fluctuant current distribution around cathodic zones was observed the first time. The potential and current maps showed that the enzyme heterogeneity of the artificial biofilm caused a corresponding electrochemical heterogeneity at the biofilm/metal interface. The application of the WBE method to ennoblement study enables us to observe the heterogeneous electrochemistry at biofilm/stainless steel interface directly, providing us with a powerful tool to investigate other biofilm-related processes such as microbially influenced corrosion (MIC).

  16. Influence of heat input on weld bead geometry using duplex stainless steel wire electrode on low alloy steel specimens

    Directory of Open Access Journals (Sweden)

    Ajit Mondal

    2016-12-01

    Full Text Available Gas metal arc welding cladding becomes a popular surfacing technique in many modern industries as it enhances effectively corrosion resistance property and wear resistance property of structural members. Quality of weld cladding may be enhanced by controlling process parameters. If bead formation is found acceptable, cladding is also expected to be good. Weld bead characteristics are often assessed by bead geometry, and it is mainly influenced by heat input. In this paper, duplex stainless steel E2209 T01 is deposited on E250 low alloy steel specimens with 100% CO2 gas as shielding medium with different heats. Weld bead width, height of reinforcement and depth of penetration are measured. Regression analysis is done on the basis of experimental data. Results reveal that within the range of bead-on-plate welding experiments done, parameters of welding geometry are on the whole linearly related with heat input. A condition corresponding to 0.744 kJ/mm heat input is recommended to be used for weld cladding in practice.

  17. Electrochemical properties of GaN nanowire electrodes--influence of doping and control by external bias.

    Science.gov (United States)

    Wallys, J; Hoffmann, S; Furtmayr, F; Teubert, J; Eickhoff, M

    2012-04-27

    We report on the electrochemical characteristics of GaN nanowire (NW) ensembles grown by plasma-assisted molecular beam epitaxy on Si111 substrates and on the influence of Si and Mg doping. The NW electrochemical properties in terms of surface capacitance (C(S)), surface resistance (R(S)) are extracted from electrochemical impedance spectra. While Mg doping of GaN NWs does not cause a significant variation of these quantities, an increase of the Si concentration leads to an increase of C(S) and a simultaneous decrease of R(S), indicating the presence of charge carriers in the NWs. According to the extracted values for R(S) and C(S) the NWs are classified into resistive and conductive. For conductive NWs charge transfer to a ferricyanide redox couple in the electrolyte is demonstrated and the ensemble average of the flatband voltage was determined. Variation of the lateral surface potential due to application of an external bias via the electrolyte is demonstrated.

  18. Point Electrode Studies of the Solid Electrolyte-Electrode Interface

    DEFF Research Database (Denmark)

    Jacobsen, Torben

    may be masked by memory effects. The aim of the present work is clarify to what extent the picture of a point electrode as a surface in intimate contact surrounded by a reaction zone is influenced by these processes, and to obtain more information on the mechanisms. The basic idea....... A condition for this to work in a reproducible manner is that the properties of the reaction zone are stable. Recent studies have shown that the activity of the reaction zone is influenced by the electrode reaction itself and changes in the morphology have been observed by AFM (1,2,3). As consequence results...

  19. Microstructure of plastic bonded nickel electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Kulcsar, S.; Agh, J.; Fazekas, A.; Vigh, J.; Bujdoso, Z.

    1982-07-01

    Structure is of great importance in the characteristics of plastic bonded nickel electrodes. On the basis of SEM tests it has been established that in pressed Ni electrodes some tenth of a millimetre-long PTFE fibres can be found with a diameter smaller than 500 nm. These form a net-like structure in the electrode which holds the active material together without any decrease in the conductivity. The formation and arrangement of this structure can be influenced by technological parameters.

  20. Tracer Studies of the Influence of Foreign Substances at the Surface of the Electrodes. I. Polarization Phenomena; Accion de las sustancias extranas en la superficie de los electrodos. Estudio mediante radiotrazadores

    Energy Technology Data Exchange (ETDEWEB)

    Llopis, J.; Gamboa, J. M.; Arizmendi, L.

    1961-07-01

    Radioactive stearic acid ({sup 1}4C) has been used to determine the number of molecular layers present on copper electrode surfaces and its distribution. The stability of these layers under the experimental conditions has been studied and it has been shown that its presence has no influence on the anodic and cathodic polarization. an increase of these polarizations has been observed with mixed multilayers of stearic acid and sterolamide. (Author) 13 refs.

  1. Influence of the electronic structures on the heterogeneous photoelectrocatalytic performance of Ti/Ru{sub x}Sn{sub 1-x}O{sub 2} electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Zhijie, E-mail: 1061739408@qq.com [College of Materials Science and Engineering, Fuzhou University, Fuzhou, Fujian 350108 (China); Zhu, Junqiu, E-mail: zhujunqiu@xmut.edu.com [School of Chemical Engineering and Materials Science, Quanzhou Normal University, Quanzhou, Fujian 362000 (China); Zhang, Shuai, E-mail: 601314274@qq.com [College of Materials Science and Engineering, Fuzhou University, Fuzhou, Fujian 350108 (China); Shao, Yanqun, E-mail: yqshao1989@163.com [College of Materials Science and Engineering, Fuzhou University, Fuzhou, Fujian 350108 (China); Lin, Deyuan, E-mail: lindeyuan_fj@126.com [Electric Power Research Institute of State Grid Fujian Electric Power Co. Ltd., Fuzhou 350007 (China); Zhou, Jianfeng, E-mail: 1277018923@qq.com [College of Materials Science and Engineering, Fuzhou University, Fuzhou, Fujian 350108 (China); Chen, Yunxiang, E-mail: rogerchen@163.com [Electric Power Research Institute of State Grid Fujian Electric Power Co. Ltd., Fuzhou 350007 (China); Tang, Dian, E-mail: diantang@fzu.edu.cn [College of Materials Science and Engineering, Fuzhou University, Fuzhou, Fujian 350108 (China)

    2017-07-05

    Highlights: • Ti/Ru{sub x}Sn{sub 1-x}O{sub 2} electrodes possessed photocatalytic and electrocatalytic activity were prepared by thermal decomposition method. • The effect of electronic structure on electronic conductivity, electrocatalytic and photocatalytic activity were studied. • The photoelectric-synergistic catalytic activity of the Ti/Ru{sub x}Sn{sub 1-x}O{sub 2} electrodes was studied upon UV irradiation. • The Ti/Ru{sub 0.05}Sn{sub 0.95}O{sub 2} electrode has good catalytic activity and excellent stability. - Abstract: DSA-type Ti/Ru{sub x}Sn{sub 1-x}O{sub 2} electrodes were prepared by thermal decomposition method as photoelectrocatalysts (PECs) and extensively characterized by various sophisticated techniques. First-principles calculations was employed to study the effects of Ru content on the electronic structures of the Ru{sub x}Sn{sub 1-x}O{sub 2} coatings. The photoelectric-synergistic catalytic activity of the Ti/Ru{sub x}Sn{sub 1-x}O{sub 2} electrodes was evaluated for the degradation of methyl orange (MO) in aqueous solution. The results show that the RuO{sub 2}−SnO{sub 2} solid solution could be formed. The band gaps of the Ru{sub x}Sn{sub 1-x}O{sub 2} coatings gradually decreased and eventually turned into metallic conductivity with the increase of ruthenium content. As a PEC electrode, reducing band gap is helpful to improve electronic conductivity and the electrocatalytic activity, but not always advantageous to increase the photocatalytic activity. Because too narrow band gap will sacrifice the photogenerated charge carriers and thus reduce photocatalytic activity of the electrode. In our experiments, the rate constant of Ti/Ru{sub 0.05}Sn{sub 0.95}O{sub 2} electrode increased with increasing Ru content and exhibited the maximum rate for 5% Ru loading. The stability test showed the photoelectrocatalytic activity of the Ti/Ru{sub 0.05}Sn{sub 0.95}O{sub 2} electrode almost had no attenuation after 100 h photoelectrolysis, revealing

  2. Mapping the Galvanic Corrosion of Three Metals Coupled with a Wire Beam Electrode: The Influence of Temperature and Relative Geometrical Position

    OpenAIRE

    Hong Ju; Yuan-Feng Yang; Yun-Fei Liu; Shu-Fa Liu; Jin-Zhuo Duan; Yan Li

    2018-01-01

    The local electrochemical properties of galvanic corrosion for three coupled metals in a desalination plant were investigated with three wire-beam electrodes as wire sensors: aluminum brass (HAl77-2), titanium (TA2), and 316L stainless steel (316L SS). These electrodes were used with artificial seawater at different temperatures. The potential and current–density distributions of the three-metal coupled system are inhomogeneous. The HAl77-2 wire anodes were corroded in the three-metal coupled...

  3. Tracer Studies of the Influence of Foreign Substances at the Surface of the Electrodes. II Influence in electro crystallization phenomena; Accion de las sustancias extranas en la superficies de los electrodos. Estudio mediante radiotrazadores. II. Influencia en los procesos de electrocristalizacion

    Energy Technology Data Exchange (ETDEWEB)

    Llopis, J.; Gamboa, J. M.; Arizmendi, L.

    1963-07-01

    The action of foreign substances present on the surface of the electrodes, in electro crystallization phenomena, has been studied. The number of Ag crystals per square centimeter of Pt electrode varies with the polishing, the current density and the presence of multilayers of stearic acid. The statistical distribution of Ag crystals without and with multilayers and their influence on the concentration index and the deformation of Ag crystals has been studied. the size of these crystals increases as the current density decreases. (Author) 16 refs.

  4. Influence of hydrogen absorption in amorphous Ni-P electrodes on double layer capacitance and charge transfer coefficient of hydrogen evolution reaction

    Czech Academy of Sciences Publication Activity Database

    Paseka, Ivo

    1999-01-01

    Roč. 44, č. 25 (1999), s. 4551-4558 ISSN 0013-4686 R&D Projects: GA ČR GA203/96/1320 Institutional research plan: CEZ:AV0Z4032918 Keywords : hydrogen absorption * hydrogen evolution * Amorphous alloys * Nickel phosphorus electrodes Subject RIV: CA - Inorganic Chemistry Impact factor: 1.325, year: 1999

  5. Flexible retinal electrode array

    Science.gov (United States)

    Okandan, Murat [Albuquerque, NM; Wessendorf, Kurt O [Albuquerque, NM; Christenson, Todd R [Albuquerque, NM

    2006-10-24

    An electrode array which has applications for neural stimulation and sensing. The electrode array can include a large number of electrodes each of which is flexibly attached to a common substrate using a plurality of springs to allow the electrodes to move independently. The electrode array can be formed from a combination of bulk and surface micromachining, with electrode tips that can include an electroplated metal (e.g. platinum, iridium, gold or titanium) or a metal oxide (e.g. iridium oxide) for biocompatibility. The electrode array can be used to form a part of a neural prosthesis, and is particularly well adapted for use in an implantable retinal prosthesis where the electrodes can be tailored to provide a uniform gentle contact pressure with optional sensing of this contact pressure at one or more of the electrodes.

  6. Micromachined electrode array

    Science.gov (United States)

    Okandan, Murat; Wessendorf, Kurt O.

    2007-12-11

    An electrode array is disclosed which has applications for neural stimulation and sensing. The electrode array, in certain embodiments, can include a plurality of electrodes each of which is flexibly attached to a common substrate using a plurality of springs to allow the electrodes to move independently. In other embodiments of the electrode array, the electrodes can be fixed to the substrate. The electrode array can be formed from a combination of bulk and surface micromachining, and can include electrode tips having an electroplated metal (e.g. platinum, iridium, gold or titanium) or a metal oxide (e.g. iridium oxide) for biocompatibility. The electrode array can be used to form a part of a neural prosthesis, and is particularly well adapted for use in an implantable retinal prosthesis.

  7. Mapping the Galvanic Corrosion of Three Metals Coupled with a Wire Beam Electrode: The Influence of Temperature and Relative Geometrical Position

    Directory of Open Access Journals (Sweden)

    Hong Ju

    2018-02-01

    Full Text Available The local electrochemical properties of galvanic corrosion for three coupled metals in a desalination plant were investigated with three wire-beam electrodes as wire sensors: aluminum brass (HAl77-2, titanium (TA2, and 316L stainless steel (316L SS. These electrodes were used with artificial seawater at different temperatures. The potential and current–density distributions of the three-metal coupled system are inhomogeneous. The HAl77-2 wire anodes were corroded in the three-metal coupled system. The TA2 wires acted as cathodes and were protected; the 316L SS wires acted as secondary cathodes. The temperature and electrode arrangement have important effects on the galvanic corrosion of the three-metal coupled system. The corrosion current of the HAl77-2 increased with temperature indicating enhanced anode corrosion at higher temperature. In addition, the corrosion of HAl77-2 was more significant when the HAl77-2 wires were located in the middle of the coupled system than with the other two metal arrangement styles.

  8. Mapping the Galvanic Corrosion of Three Metals Coupled with a Wire Beam Electrode: The Influence of Temperature and Relative Geometrical Position.

    Science.gov (United States)

    Ju, Hong; Yang, Yuan-Feng; Liu, Yun-Fei; Liu, Shu-Fa; Duan, Jin-Zhuo; Li, Yan

    2018-02-28

    The local electrochemical properties of galvanic corrosion for three coupled metals in a desalination plant were investigated with three wire-beam electrodes as wire sensors: aluminum brass (HAl77-2), titanium (TA2), and 316L stainless steel (316L SS). These electrodes were used with artificial seawater at different temperatures. The potential and current-density distributions of the three-metal coupled system are inhomogeneous. The HAl77-2 wire anodes were corroded in the three-metal coupled system. The TA2 wires acted as cathodes and were protected; the 316L SS wires acted as secondary cathodes. The temperature and electrode arrangement have important effects on the galvanic corrosion of the three-metal coupled system. The corrosion current of the HAl77-2 increased with temperature indicating enhanced anode corrosion at higher temperature. In addition, the corrosion of HAl77-2 was more significant when the HAl77-2 wires were located in the middle of the coupled system than with the other two metal arrangement styles.

  9. The influence of boron dopant on the electrochemical properties of graphene as an electrode material and a support for Pt catalysts

    International Nuclear Information System (INIS)

    Bo, Xiangjie; Li, Mian; Han, Ce; Guo, Liping

    2013-01-01

    Highlights: •More defective sites in graphene after the doping of boron atoms. •Fine dispersion of Pt nanoparticles supported on boron-doped graphene. •Low electron transfer resistance at boron-doped graphene. •High performance of boron-doped graphene as an electrode material or a support for Pt catalysts. -- Abstract: Boron-doped graphene (BGR) is prepared by thermal annealing of graphene oxide (GO) in the presence of boric acid. More defective sites are introduced into GR accompanied by the doping of boron. Low electron transfer resistance towards redox probe is observed at BGR. The BGR modified electrode can effectively distinguish the anodic peaks for ascorbic acid (AA), dopamine (DA), and uric acid (UA). The defective sites of BGR can also act as anchoring sites for the deposition of Pt nanoparticles. When used as a support for Pt electrocatalysts, Pt nanoparticles with an average diameter of 3.2 nm are deposited on BGR. The doping of boron into GR facilitates the dispersion of Pt nanoparticles and increases the utilization efficiency of Pt nanoparticles. The Pt/BGR exhibits significant catalytic activity towards the oxidation of methanol. The results demonstrate that BGR is a good support for Pt catalysts or an electrode material compared with the undoped GR

  10. Mapping the Galvanic Corrosion of Three Metals Coupled with a Wire Beam Electrode: The Influence of Temperature and Relative Geometrical Position

    Science.gov (United States)

    Liu, Yun-Fei; Liu, Shu-Fa; Duan, Jin-Zhuo

    2018-01-01

    The local electrochemical properties of galvanic corrosion for three coupled metals in a desalination plant were investigated with three wire-beam electrodes as wire sensors: aluminum brass (HAl77-2), titanium (TA2), and 316L stainless steel (316L SS). These electrodes were used with artificial seawater at different temperatures. The potential and current–density distributions of the three-metal coupled system are inhomogeneous. The HAl77-2 wire anodes were corroded in the three-metal coupled system. The TA2 wires acted as cathodes and were protected; the 316L SS wires acted as secondary cathodes. The temperature and electrode arrangement have important effects on the galvanic corrosion of the three-metal coupled system. The corrosion current of the HAl77-2 increased with temperature indicating enhanced anode corrosion at higher temperature. In addition, the corrosion of HAl77-2 was more significant when the HAl77-2 wires were located in the middle of the coupled system than with the other two metal arrangement styles. PMID:29495617

  11. Aspects of the Influence of Light on the Adsorption and Electrooxidation of Allyl Alcohol on Pt/Pt Electrodes in Perchloric Acid Solutions

    Directory of Open Access Journals (Sweden)

    Barin Claudia Smaniotto

    1998-01-01

    Full Text Available The electrooxidation of the adsorbed species produced by allyl alcohol adsorption on platinized platinum electrode has been studied in 1.0 M HClO4 medium. The maximum amount of adsorbed intermediates formed during allyl alcohol adsorption on the electrode surface, was observed at the adsorption potential, Eads = 0.00 V (SCE. Chronoamperometric studies at this potential confirm that the current associated with the hydrogen adsorption process decreases in the presence of the organic compound. Allyl alcohol displaces adsorbed hydrogen at the active sites. The incidence of polychromatic light on the electrode improves this effect as shown by comparison with the same experiments in the darkness. However, the electrooxidation of the adsorbed species comprise a monoelectronic charge transfer step. The anodic current associated with this process was higher under illumination than in the dark. This difference was attributed to a light-induced effect: either on the adsorption process of allyl alcohol on Pt/Pt, or on the electrooxidation of the adsorbed species. The electrooxidation of the adsorbed species formed during allyl alcohol adsorption demands apparent activation energies equivalent to 33.3 kJ mol-1 and 24.9 kJ mol-1 in the dark and under illumination, respectively.

  12. A Simple Hydrogen Electrode

    Science.gov (United States)

    Eggen, Per-Odd

    2009-01-01

    This article describes the construction of an inexpensive, robust, and simple hydrogen electrode, as well as the use of this electrode to measure "standard" potentials. In the experiment described here the students can measure the reduction potentials of metal-metal ion pairs directly, without using a secondary reference electrode. Measurements…

  13. The Composite Insertion Electrode

    DEFF Research Database (Denmark)

    Atlung, Sven; Zachau-Christiansen, Birgit; West, Keld

    1984-01-01

    The specific energy obtainable by discharge of porous insertion electrodes is limited by electrolyte depletion in thepores. This can be overcome using a solid ion conductor as electrolyte. The term "composite" is used to distinguishthese electrodes from porous electrodes with liquid electrolyte...

  14. Mechanical characterization of Cu-Zn wire electrode base used in EDM and study of influence of the process of machining on its properties

    Energy Technology Data Exchange (ETDEWEB)

    Sedjal, H., E-mail: hasedjal@yahoo.fr; Amirat, B. [Département of Mechanical engineering, University of M.MAMMERI, Tizi Ouzou (Algeria); Aichour, M.; Marouf, T.; Chitroub, M. [Engineering and Material Sciences Laboratory, Department of Metallurgy, Polytechnic national school, Algiers (Algeria)

    2015-03-30

    This work is part of a Research National project (PNR) carried out by the group of research of the engineering and material sciences laboratory of the polytechnic national school at Algiers in collaboration with company BCR, which relates to “the characterization of the wire intended for the EDM of matrices metal. The goal of this work is to bring metallographic explanations on the wire electrode used by the machine ROBOFIL 290P, mechanically characterized this wire as of knowing of advantage about the process of its manufacturing (wiredrawing, .) The methods of studies used are it micro Vickers pyramid hardness, the tensile test, optical microscopy and scan electronic microscopy SEM.

  15. Regenerative scaffold electrodes for peripheral nerve interfacing.

    Science.gov (United States)

    Clements, Isaac P; Mukhatyar, Vivek J; Srinivasan, Akhil; Bentley, John T; Andreasen, Dinal S; Bellamkonda, Ravi V

    2013-07-01

    Advances in neural interfacing technology are required to enable natural, thought-driven control of a prosthetic limb. Here, we describe a regenerative electrode design in which a polymer-based thin-film electrode array is integrated within a thin-film sheet of aligned nanofibers, such that axons regenerating from a transected peripheral nerve are topographically guided across the electrode recording sites. Cultures of dorsal root ganglia were used to explore design parameters leading to cellular migration and neurite extension across the nanofiber/electrode array boundary. Regenerative scaffold electrodes (RSEs) were subsequently fabricated and implanted across rat tibial nerve gaps to evaluate device recording capabilities and influence on nerve regeneration. In 20 of these animals, regeneration was compared between a conventional nerve gap model and an amputation model. Characteristic shaping of regenerated nerve morphology around the embedded electrode array was observed in both groups, and regenerated axon profile counts were similar at the eight week end point. Implanted RSEs recorded evoked neural activity in all of these cases, and also in separate implantations lasting up to five months. These results demonstrate that nanofiber-based topographic cues within a regenerative electrode can influence nerve regeneration, to the potential benefit of a peripheral nerve interface suitable for limb amputees.

  16. Influence of aqueous KOH and H2SO4 electrolytes ionic parameters on the performance of carbon-based supercapacitor electrodes

    Science.gov (United States)

    Mohd Hanappi, Mohamad Faizal Yusman; Deraman, Mohamad; Suleman, Mohd; Mohd Nor, Najah Syahirah; Sazali, Noor Ezniera Shafieza; Hamdan, Ellisa; Moh Tajuddin, Nurul Syazwani; Basri, Nur Hamizah; Mohd Jasni, Mohd Redwani; Othman, Mohd Amir Radhi

    In this paper, the suitability of aqueous KOH and H2SO4 electrolytes in terms of ionic size, mobility, conductivity and energy of electrolyte ions with the porosity of activated carbon electrodes are demonstrated. These parameters of ions (K+, OH-, H+, SO42-) are found to affect the overall performances of supercapacitor cells as observed from the results of EIS, CV and GCD studies. The cell using H2SO4 electrolyte exhibits better performance with relatively low value of charge transfer resistance (0.57Ω), overall cell resistance, 19Ω (at 10mHz) and high value of specific capacitance 547F g-1 (at 1mV s-1), specific energy 10W h kg-1 (at 0.5A g-1) and specific power, 490W kg-1. These results show that aqueous acid electrolyte is more compatible with carbon electrodes which could be due to the higher ionic energies of H+ and SO42- ions.

  17. Influence of Pt Gate Electrode Thickness on the Hydrogen Gas Sensing Characteristics of Pt/In2O3/SiC Hetero-Junction Devices

    Directory of Open Access Journals (Sweden)

    S. Kandasamy

    2007-09-01

    Full Text Available Hetero-junction Pt/In2O3/SiC devices with different Pt thickness (30, 50 and 90nm were fabricated and their hydrogen gas sensing characteristics have been studied. Pt and In2O3 thin films were deposited by laser ablation. The hydrogen sensitivity was found to increase with decreasing Pt electrode thickness. For devices with Pt thickness of 30 nm, the sensitivity gradually increased with increasing temperature and reached a maximum of 390 mV for 1% hydrogen in air at 530°C. Atomic force microscopy (AFM analysis revealed a decrease in Pt grain size and surface roughness for increasing Pt thickness. The relationship between the gas sensing performance and the Pt film thickness and surface morphology is discussed.

  18. Influence of the lithium salt nature over the surface film formation on a graphite electrode in Li-ion batteries: An XPS study

    International Nuclear Information System (INIS)

    Leroy, S.; Martinez, H.; Dedryvere, R.; Lemordant, D.; Gonbeau, D.

    2007-01-01

    The formation of a passivation film (solid electrolyte interphase, SEI) at the surface of the negative electrode of full LiCoO 2 /graphite lithium-ion cells using different salts (LiBF 4 , LiPF 6 , LiTFSI, LiBETI) in carbonate solvents as electrolyte was investigated by X-ray photoelectron spectroscopy (XPS). The analyzes were carried out at different potential stages of the first cycle, showing the potential-dependent character of the surface film species formation and the specificity of each salt. At 3.8 V, for all salts, we have mainly identified carbonated species. Beyond this potential, the specific behavior of LiPF 6 was identified with a high LiF deposit, whereas for other salts, the formation process of the SEI appears controlled by the solvent decomposition of the electrolyte

  19. Handbook of reference electrodes

    CERN Document Server

    Inzelt, György; Scholz, Fritz

    2013-01-01

    Reference Electrodes are a crucial part of any electrochemical system, yet an up-to-date and comprehensive handbook is long overdue. Here, an experienced team of electrochemists provides an in-depth source of information and data for the proper choice and construction of reference electrodes. This includes all kinds of applications such as aqueous and non-aqueous solutions, ionic liquids, glass melts, solid electrolyte systems, and membrane electrodes. Advanced technologies such as miniaturized, conducting-polymer-based, screen-printed or disposable reference electrodes are also covered. Essen

  20. Thin metal electrodes for semitransparent organic photovoltaics

    KAUST Repository

    Lee, Kyusung

    2013-08-01

    We demonstrate semitransparent organic photovoltaics (OPVs) based on thin metal electrodes and polymer photoactive layers consisting of poly(3-hexylthiophene) and [6,6]-phenyl C61 butyric acid methyl ester. The power conversion efficiency of a semitransparent OPV device comprising a 15-nm silver (Ag) rear electrode is 1.98% under AM 1.5-G illumination through the indium-tin-oxide side of the front anode at 100 mW/cm2 with 15.6% average transmittance of the entire cell in the visible wavelength range. As its thickness increases, a thin Ag electrode mainly influences the enhancement of the short circuit current density and fill factor. Its relatively low absorption intensity makes a Ag thin film a viable option for semitransparent electrodes compatible with organic layers. © 2013 ETRI.

  1. Disposable biomedical electrode

    Science.gov (United States)

    Frost, J. D., Jr.; Hillman, C. E., Jr.

    1977-01-01

    Reusable recording cap equipped with compressible snap-on bioelectronic electrodes is worn by patient to allow remote monitoring of electroencephalogram and electro-oculogram waveforms. Electrodes can be attached to inside surface of stretch-textile cap at twelve monitoring positions and at one or two ground positions.

  2. Durable fuel electrode

    DEFF Research Database (Denmark)

    2017-01-01

    the composite. The invention also relates to the use of the composite as a fuel electrode, solid oxide fuel cell, and/or solid oxide electrolyser. The invention discloses a composite for an electrode, comprising a three-dimensional network of dispersed metal particles, stabilised zirconia particles and pores...

  3. The Behavioral Effects of tDCS on Visual Search Performance Are Not Influenced by the Location of the Reference Electrode

    Directory of Open Access Journals (Sweden)

    Amanda Ellison

    2017-09-01

    Full Text Available We investigated the role of reference electrode placement (ipsilateral v contralateral frontal pole on conjunction visual search task performance when the transcranial direct current stimulation (tDCS cathode is placed over right posterior parietal cortex (rPPC and over right frontal eye fields (rFEF, both of which have been shown to be causally involved in the processing of this task using TMS. This resulted in four experimental manipulations in which sham tDCS was applied in week one followed by active tDCS the following week. Another group received sham stimulation in both sessions to investigate practice effects over 1 week in this task. Results show that there is no difference between effects seen when the anode is placed ipsi or contralaterally. Cathodal stimulation of rPPC increased search times straight after stimulation similarly for ipsi and contralateral references. This finding does not extend to rFEF stimulation. However, for both sites and both montages, practice effects as seen in the sham/sham condition were negated. This can be taken as evidence that for this task, reference placement on either frontal pole is not important, but also that care needs to be taken when contextualizing tDCS “effects” that may not be immediately apparent particularly in between-participant designs.

  4. Surface modification of recording electrodes

    Directory of Open Access Journals (Sweden)

    Iaci Miranda Pereira

    2013-01-01

    Full Text Available Waterborne Polyurethanes (PUs are a family of polymers that contains urethane linkages synthesized in an aqueous environment and are thus free of organic solvents. Recently, waterborne PUs have been extensively studied for biomedical applications because of their biocompatibility. The present work investigates the following: (1 the impact on electrical performance of electrode materials (platinum and silicon modified chemically by a layer of waterborne PU, and (2 the behavior of rat cardiac fibroblasts and rat cardiomyocytes when in contact with an electrode surface. Diisocyanate and poly(caprolactone diol were the main reagents for producing PUs. The electrochemical impedance of the electrode/electrolyte interface was accessed by electrochemical impedance spectroscopy. The cellular viability, proliferation, and morphology changes were investigated using an MTT assay. Cardiomyocyte adherence was observed by scanning electron microscopy. The obtained surface was uniform, flat, and transparent. The film showed good adhesion, and no peeling was detected. The electrochemical impedance decreased over time and was influenced by the ionic permeability of the PU layer. The five samples did not show cytotoxicity when in contact with neonatal rat cells.

  5. Porous graphite electrodes for rechargeable ion-transfer batteries

    Energy Technology Data Exchange (ETDEWEB)

    Novak, P.; Scheifele, W.; Haas, O. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-06-01

    The influence of preparation pressure and pore-forming additives on the properties of graphite-based, Li{sup +}-intercalating electrodes for ion-transfer batteries have been investigated. The electrochemical performance of graphite electrodes could be improved by adjusting the porosity. Specific charge of >300 Ah/kg (with respect to the graphite mass) could be achieved. (author) 4 figs., 2 refs.

  6. Influence of Oxygen Concentration on the Performance of Ultra-Thin RF Magnetron Sputter Deposited Indium Tin Oxide Films as a Top Electrode for Photovoltaic Devices

    Directory of Open Access Journals (Sweden)

    Jephias Gwamuri

    2016-01-01

    Full Text Available The opportunity for substantial efficiency enhancements of thin film hydrogenated amorphous silicon (a-Si:H solar photovoltaic (PV cells using plasmonic absorbers requires ultra-thin transparent conducting oxide top electrodes with low resistivity and high transmittances in the visible range of the electromagnetic spectrum. Fabricating ultra-thin indium tin oxide (ITO films (sub-50 nm using conventional methods has presented a number of challenges; however, a novel method involving chemical shaving of thicker (greater than 80 nm RF sputter deposited high-quality ITO films has been demonstrated. This study investigates the effect of oxygen concentration on the etch rates of RF sputter deposited ITO films to provide a detailed understanding of the interaction of all critical experimental parameters to help create even thinner layers to allow for more finely tune plasmonic resonances. ITO films were deposited on silicon substrates with a 98-nm, thermally grown oxide using RF magnetron sputtering with oxygen concentrations of 0, 0.4 and 1.0 sccm and annealed at 300 °C air ambient. Then the films were etched using a combination of water and hydrochloric and nitric acids for 1, 3, 5 and 8 min at room temperature. In-between each etching process cycle, the films were characterized by X-ray diffraction, atomic force microscopy, Raman Spectroscopy, 4-point probe (electrical conductivity, and variable angle spectroscopic ellipsometry. All the films were polycrystalline in nature and highly oriented along the (222 reflection. Ultra-thin ITO films with record low resistivity values (as low as 5.83 × 10−4 Ω·cm were obtained and high optical transparency is exhibited in the 300–1000 nm wavelength region for all the ITO films. The etch rate, preferred crystal lattice growth plane, d-spacing and lattice distortion were also observed to be highly dependent on the nature of growth environment for RF sputter deposited ITO films. The structural, electrical

  7. Influence of monomer concentration during polymerization on performance and catalytic mechanism of resultant poly(3,4-ethylenedioxythiophene) counter electrodes for dye-sensitized solar cells

    International Nuclear Information System (INIS)

    Han, Ruobing; Lu, Shan; Wang, Yanjie; Zhang, Xuehua; Wu, Qiang; He, Tao

    2015-01-01

    Graphical abstract: Display Omitted -- Highlights: •EDOT concentration has great impact on the properties of as-prepared PEDOT CEs. •PEDOT CE polymerized with low EDOT concentration shows better conductivity. •PEDOT polymerized with high EDOT concentration has more catalytic reaction centers. •Undoped EDOT units in PEDOT are key catalytic centers for I − /I 3 − redox reaction. •PEDOT CEs based DSSCs exhibit comparable power conversion efficiency to Pt CE. -- Abstract: Poly(3,4-ethylenedioxythiophene) (PEDOT) films doped by perchlorate ions (ClO 4 − ) have been prepared via electropolymerization with different EDOT monomer concentration and used as counter electrodes (CEs) in dye-sensitized solar cells (DSSCs). The effect of EDOT monomer concentration on the properties of obtained PEDOT CEs has been thoroughly investigated. The sponge like porous microstructure of the PEDOT films breaks gradually with the increase of EDOT concentration. Meanwhile, the conductivity of the PEDOT CEs decreases gradually due to the decreased ClO 4 − doping level. The catalytic mechanism is mainly comprised of the formation of weakly bonded iodine species on the undoped EDOT units, and formation and reduction of the intermediates. The undoped EDOT units in the PEDOT chain are the key catalytic reaction centers for I − /I 3 − redox reaction. The catalytic activity of the PEDOT CEs for I − /I 3 − redox reaction increases with the increase of EDOT concentration by virtue of the increased catalytic reaction centers in the PEDOT chain (i.e., increased undoped EDOT units due to the decreased ClO 4 − doping level). DSSC based on PEDOT CE polymerized with 0.05 M of EDOT and 0.1 M of LiClO 4 shows good photovoltaic performance, with a power conversion efficiency of 7.42%. This result is comparable to the Pt CE based-solar cell (7.41%), suggesting that PEDOT CEs may substitute the expensive Pt CEs in the DSSCs

  8. Temperature-controlled radiofrequency ablation of cardiac tissue: an in vitro study of the impact of electrode orientation, electrode tissue contact pressure and external convective cooling

    DEFF Research Database (Denmark)

    Petersen, H H; Chen, X; Pietersen, A

    1999-01-01

    A variety of basic factors such as electrode tip pressure, flow around the electrode and electrode orientation influence lesion size during radiofrequency ablation, but importantly is dependent on the chosen mode of ablation. However, only little information is available for the frequently used...... temperature-controlled mode. The purpose of the present experimental study was to evaluate the impact during temperature-controlled radiofrequency ablation of three basic factors regarding electrode-tissue contact and convective cooling on lesion size....

  9. Study of electric discharges between moving electrodes in air

    International Nuclear Information System (INIS)

    Andreev, V. V.; Pichugin, Yu. P.; Telegin, V. G.; Telegin, G. G.

    2011-01-01

    A barrier electric discharge excited between a fixed electrode and a rotating electrode covered with a dielectric layer in atmospheric-pressure air is studied experimentally. A distinctive feature of this type of discharge is that it operates at a constant voltage between the electrodes. An advantage of the proposed method for plasma generation in the boundary layer of the rotating electrode (e.g., for studying the influence of plasma on air flows) is the variety of forms of the discharge and conditions for its initiation, simplicity of the design of the discharge system, and ease of its practical implementation

  10. Study of electric discharges between moving electrodes in air

    Energy Technology Data Exchange (ETDEWEB)

    Andreev, V. V.; Pichugin, Yu. P.; Telegin, V. G.; Telegin, G. G. [Chuvash State University (Russian Federation)

    2011-12-15

    A barrier electric discharge excited between a fixed electrode and a rotating electrode covered with a dielectric layer in atmospheric-pressure air is studied experimentally. A distinctive feature of this type of discharge is that it operates at a constant voltage between the electrodes. An advantage of the proposed method for plasma generation in the boundary layer of the rotating electrode (e.g., for studying the influence of plasma on air flows) is the variety of forms of the discharge and conditions for its initiation, simplicity of the design of the discharge system, and ease of its practical implementation.

  11. Sensor employing internal reference electrode

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention concerns a novel internal reference electrode as well as a novel sensing electrode for an improved internal reference oxygen sensor and the sensor employing same.......The present invention concerns a novel internal reference electrode as well as a novel sensing electrode for an improved internal reference oxygen sensor and the sensor employing same....

  12. Dual-electrode biasing experiments in KT-5C device

    International Nuclear Information System (INIS)

    Yu Yi; Lu Ronghua; Wang Chen; Pan Geshen; Wen Yizhi; Yu Changxuan; Ma Jinxiu; Wan Shude; Liu Wandong

    2005-01-01

    Based on the single biasing electrode experiments to optimize the confinement of plasma in the device of KT-5C tokamak, dual-biasing electrodes were inserted into the KT5C plasma for the first time to explore the enhancement of the effects of biasing and the mechanisms of the biasing. By means of applying different combinations of biasing voltages to the dual electrodes, the changes in E r , which is the key factor for boosting up the Er x B flow shear, were observed. The time evolution showed the inner electrode played a major role in dual-biasing, for it always drew a larger current than the outer one. The outer electrode made little influence. It turned out that the dual-biasing electrodes were as effective as a single one, in improving plasma confinement, for the mechanism of biasing was essentially an edge effect. (author)

  13. Textile electrodes in Electrical Bioimpedance measurements - a comparison with conventional Ag/AgCl electrodes.

    Science.gov (United States)

    Marquez, J C; Seoane, F; Välimäki, E; Lindecrantz, K

    2009-01-01

    Work has been intensified around the integration of textile and measurement technology for physiological measurements in the last years. As a result nowadays it is possible to find available commercial products for cardiovascular personal healthcare monitoring. Most of the efforts have been focused in the acquisition of EKG for cardiovascular monitoring where textile electrodes have shown satisfactory performance. Electrical Bioimpedance is another type of physiological measurement that can be used for personal healthcare monitoring where the integration and the performance of the textile electrodes has not been investigated that thoroughly. In this work, the influence of the textile electrodes on the measurements and on the estimation of the Cole (R(0), R(infinity), f(C) and alpha) and body composition (TBW, ICW, ECW and FFM) parameters has been especially addressed. Complex Spectroscopy 4-electrode wrist-to-ankle electrical bioimpedance measurements taken with conventional Ag/AgCl and textile-electrodes on customized bracelets have been compared and analyzed in the frequency range 3 to 500 kHz. The obtained results suggest that the use of textile electrodes do not influence remarkably on the complex spectral measurements neither in the estimation of Cole nor body composition parameter. In any case any possible effect introduced by the use of textile is smaller than the effect of preparing the skin by the using abrasive conductive paste.

  14. Transparent Electrodes with Nanotubes and Graphene for Printed Optoelectronic Applications

    Directory of Open Access Journals (Sweden)

    Marcin Słoma

    2014-01-01

    Full Text Available We report here on printed electroluminescent structures containing transparent electrodes made of carbon nanotubes and graphene nanoplatelets. Screen-printing and spray-coating techniques were employed. Electrodes and structures were examined towards optical parameters using spectrophotometer and irradiation meter. Electromechanical properties of transparent electrodes are exterminated with cyclical bending test. Accelerated aging process was conducted according to EN 62137 standard for reliability tests of electronics. We observed significant negative influence of mechanical bending on sheet resistivity of ITO, while resistivity of nanotube and graphene based electrodes remained stable. Aging process has also negative influence on ITO based structures resulting in delamination of printed layers, while those based on carbon nanomaterials remained intact. We observe negligible changes in irradiation for structures with carbon nanotube electrodes after accelerated aging process. Such materials demonstrate a high application potential in general purpose electroluminescent devices.

  15. Influence of the concentration of borohydride towards hydrogen production and escape for borohydride oxidation reaction on Pt and Au electrodes - experimental and modelling insights

    Science.gov (United States)

    Olu, Pierre-Yves; Bonnefont, Antoine; Braesch, Guillaume; Martin, Vincent; Savinova, Elena R.; Chatenet, Marian

    2018-01-01

    The Borohydride Oxidation Reaction (BOR), the anode reaction in a Direct borohydride fuel cell (DBFC), is complex and still poorly understood, which impedes the development and deployment of the DBFC technology. In particular, no practical electrocatalyst is capable to prevent gaseous hydrogen generation and escape from its anode upon operation, which lowers the fuel-efficiency of the DBFC and raises safety issues in operation. The nature of the anode electrocatalysts strongly influences the hydrogen escape characteristics of the DBFC, which demonstrates how important it is to isolate the BOR mechanism in conditions relevant to DBFC operation. In this paper, from a selected literature review and BOR experiments performed in differential electrochemical mass spectrometry (DEMS) in a wide range of NaBH4 concentration (5-500 mM), a microkinetic model of the BOR for both Pt and Au surfaces is proposed; this model takes into account the hydrogen generation and escape.

  16. Composite carbon foam electrode

    Science.gov (United States)

    Mayer, Steven T.; Pekala, Richard W.; Kaschmitter, James L.

    1997-01-01

    Carbon aerogels used as a binder for granularized materials, including other forms of carbon and metal additives, are cast onto carbon or metal fiber substrates to form composite carbon thin film sheets. The thin film sheets are utilized in electrochemical energy storage applications, such as electrochemical double layer capacitors (aerocapacitors), lithium based battery insertion electrodes, fuel cell electrodes, and electrocapacitive deionization electrodes. The composite carbon foam may be formed by prior known processes, but with the solid particles being added during the liquid phase of the process, i.e. prior to gelation. The other forms of carbon may include carbon microspheres, carbon powder, carbon aerogel powder or particles, graphite carbons. Metal and/or carbon fibers may be added for increased conductivity. The choice of materials and fibers will depend on the electrolyte used and the relative trade off of system resistivty and power to system energy.

  17. Ion-selective electrodes

    CERN Document Server

    Mikhelson, Konstantin N

    2013-01-01

    Ion-selective electrodes (ISEs) have a wide range of applications in clinical, environmental, food and pharmaceutical analysis as well as further uses in chemistry and life sciences. Based on his profound experience as a researcher in ISEs and a course instructor, the author summarizes current knowledge for advanced teaching and training purposes with a particular focus on ionophore-based ISEs. Coverage includes the basics of measuring with ISEs, essential membrane potential theory and a comprehensive overview of the various classes of ion-selective electrodes. The principles of constructing I

  18. Single Electrode Heat Effects

    DEFF Research Database (Denmark)

    Jacobsen, Torben; Broers, G. H. J.

    1977-01-01

    The heat evolution at a single irreversibly working electrode is treated onthe basis of the Brønsted heat principle. The resulting equation is analogous to the expression for the total heat evolution in a galvanic cellwith the exception that –DeltaS is substituted by the Peltier entropy, Delta......SP, of theelectrode reaction. eta is the overvoltage at the electrode. This equation is appliedto a high temperature carbonate fuel cell. It is shown that the Peltier entropyterm by far exceeds the heat production due to the irreversible losses, and thatthe main part of heat evolved at the cathode is reabsorbed...

  19. Aluminum reference electrode

    Science.gov (United States)

    Sadoway, Donald R.

    1988-01-01

    A stable reference electrode for use in monitoring and controlling the process of electrolytic reduction of a metal. In the case of Hall cell reduction of aluminum, the reference electrode comprises a pool of molten aluminum and a solution of molten cryolite, Na.sub.3 AlF.sub.6, wherein the electrical connection to the molten aluminum does not contact the highly corrosive molten salt solution. This is accomplished by altering the density of either the aluminum (decreasing the density) or the electrolyte (increasing the density) so that the aluminum floats on top of the molten salt solution.

  20. Electrical properties of textile electrodes.

    Science.gov (United States)

    Rattfalt, Linda; Chedid, Michel; Hult, Peter; Lindén, Maria; Ask, Per

    2007-01-01

    In this study we aim to explain the behavior of textile electrodes due to their construction techniques. Three textile electrodes were tested for electrode impedance and polarization potentials. The multifilament yarn (A) is favorable for its low thread resistance. Although, when knitted into electrodes, the staple fiber yarn (B) showed a comparable and satisfiable electrode impedance. The multifilament yarn had however a lower polarization potential drift then the other specimens. The monofilament yarn (C) had high electrode impedance and varying mean polarization potentials due to its conductive material and small contact area with the skin.

  1. EFFECTS OF ELECTRODE DEFORMATION OF RESISTANCE SPOT WELDING ON 304 AUSTENITIC STAINLESS STEEL WELD GEOMETRY

    Directory of Open Access Journals (Sweden)

    Nachimani Charde

    2012-12-01

    Full Text Available The resistance spot welding process is accomplished by forcing huge amounts of current flow from the upper electrode tip through the base metals to the lower electrode tip, or vice versa or in both directions. A weld joint is established between the metal sheets through fusion, resulting in a strong bond between the sheets without occupying additional space. The growth of the weld nugget (bond between sheets is therefore determined from the welding current density; sufficient time for current delivery; reasonable electrode pressing force; and the area provided for current delivery (electrode tip. The welding current and weld time control the root penetration, while the electrode pressing force and electrode tips successfully accomplish the connection during the welding process. Although the welding current and weld time cause the heat generation at the areas concerned (electrode tip area, the electrode tips’ diameter and electrode pressing forces also directly influence the welding process. In this research truncated-electrode deformation and mushrooming effects are observed, which result in the welded areas being inconsistent due to the expulsion. The copper to chromium ratio is varied from the tip to the end of the electrode whilst the welding process is repeated. The welding heat affects the electrode and the electrode itself influences the shape of the weld geometry.

  2. Dry EEG Electrodes

    Directory of Open Access Journals (Sweden)

    M. A. Lopez-Gordo

    2014-07-01

    Full Text Available Electroencephalography (EEG emerged in the second decade of the 20th century as a technique for recording the neurophysiological response. Since then, there has been little variation in the physical principles that sustain the signal acquisition probes, otherwise called electrodes. Currently, new advances in technology have brought new unexpected fields of applications apart from the clinical, for which new aspects such as usability and gel-free operation are first order priorities. Thanks to new advances in materials and integrated electronic systems technologies, a new generation of dry electrodes has been developed to fulfill the need. In this manuscript, we review current approaches to develop dry EEG electrodes for clinical and other applications, including information about measurement methods and evaluation reports. We conclude that, although a broad and non-homogeneous diversity of approaches has been evaluated without a consensus in procedures and methodology, their performances are not far from those obtained with wet electrodes, which are considered the gold standard, thus enabling the former to be a useful tool in a variety of novel applications.

  3. Electrochemistry on nanopillared electrodes

    Directory of Open Access Journals (Sweden)

    Chandni Lotwala

    2017-02-01

    Full Text Available The addition of nanopillars to electrodes increases their electrochemical capabilities through an increase in electroactive surface area. The nanopillars can be applied on either cathodes or anodes to engage in reduction-oxidation reactions. This minireview summaries some work on cyclic voltammetry, chronoamperometry, impedance change on nanopillared surface and compared their electrochemistry behavior on planar surfaces.

  4. Ion-selective electrode reviews

    CERN Document Server

    Thomas, J D R

    1985-01-01

    Ion-Selective Electrode Reviews, Volume 7 is a collection of papers that covers the applications of electrochemical sensors, along with the versatility of ion-selective electrodes. The coverage of the text includes solid contact in membrane ion-selective electrodes; immobilized enzyme probes for determining inhibitors; potentiometric titrations based on ion-pair formation; and application of ion-selective electrodes in soil science, kinetics, and kinetic analysis. The text will be of great use to chemists and chemical engineers.

  5. Characterization of dry biopotential electrodes.

    Science.gov (United States)

    Xie, Li; Yang, Geng; Xu, Linlin; Seoane, Fernando; Chen, Qiang; Zheng, Lirong

    2013-01-01

    Driven by the increased interest in wearable long-term healthcare monitoring systems, varieties of dry electrodes are proposed based on different materials with different patterns and structures. Most of the studies reported in the literature focus on proposing new electrodes and comparing its performance with commercial electrodes. Few papers are about detailed comparison among different dry electrodes. In this paper, printed metal-plate electrodes, textile based electrodes, and spiked electrodes are for the first time evaluated and compared under the same experimental setup. The contact impedance and noise characterization are measured. The in-vivo electrocardiogram (ECG) measurement is applied to evaluate the overall performance of different electrodes. Textile electrodes and printed electrodes gain comparable high-quality ECG signals. The ECG signal obtained by spiked electrodes is noisier. However, a clear ECG envelope can be observed and the signal quality can be easily improved by backend signal processing. The features of each type of electrodes are analyzed and the suitable application scenario is addressed.

  6. Zinc electrode in alkaline electrolyte

    Energy Technology Data Exchange (ETDEWEB)

    McBreen, J.

    1995-12-31

    The zinc electrode in alkaline electrolyte is unusual in that supersaturated zincate solutions can form during discharge and spongy or mossy zinc deposits can form on charge at low overvoltages. The effect of additives on regular pasted ZnO electrodes and calcium zincate electrodes is discussed. The paper also reports on in situ x-ray absorption (XAS) results on mossy zinc deposits.

  7. Electrode design and insertional depth-dependent intra-cochlear pressure changes: a model experiment.

    Science.gov (United States)

    Mittmann, P; Ernst, A; Todt, I

    2018-03-01

    Preservation of residual hearing is one of the major goals in modern cochlear implant surgery. Intra-cochlear fluid pressure changes influence residual hearing, and should be kept low before, during and after cochlear implant insertion. Experiments were performed in an artificial cochlear model. A pressure sensor was inserted in the apical part. Five insertions were performed on two electrode arrays. Each insertion was divided into three parts, and statistically evaluated in terms of pressure peak frequency and pressure peak amplitude. The peak frequency over each third part of the electrode increased in both electrode arrays. A slight increase was seen in peak amplitude in the lateral wall electrode array, but not in the midscalar electrode array. Significant differences were found in the first third of both electrode arrays. The midscalar and lateral wall electrode arrays have different intra-cochlear fluid pressure changes associated with intra-cochlear placement, electrode characteristics and insertion.

  8. On the importance of electrode parameters for shaping electric field patterns generated by tDCS

    DEFF Research Database (Denmark)

    B. Saturnino, Guilherme; Antunes, André; Thielscher, Axel

    2015-01-01

    Transcranial direct current stimulation (tDCS) uses electrode pads placed on the head to deliver weak direct current to the brain and modulate neuronal excitability. The effects depend on the intensity and spatial distribution of the electric field. This in turn depends on the geometry and electric...... electrode modeling influences the calculated electric field in the brain. We take into account electrode shape, size, connector position and conductivities of different electrode materials (including saline solutions and electrode gels). These factors are systematically characterized to demonstrate...... their impact on the field distribution in the brain. The goals are to assess the effect of simplified electrode models; and to develop practical rules-of-thumb to achieve a stronger stimulation of the targeted brain regions underneath the electrode pads. We show that for standard rectangular electrode pads...

  9. Characterization of Transition-Metal Oxide Deposition on Carbon Electrodes of a Supercapacitor

    Directory of Open Access Journals (Sweden)

    Ying-Chung Chen

    2016-12-01

    Full Text Available In order to fabricate the composite electrodes of a supercapacitor, transition-metal oxide materials NiO and WO3 were deposited on carbon electrodes by electron beam evaporation. The influences of various transition-metal oxides, scan rates of cyclic voltammograms (CVs, and galvanostatic charge/discharge tests on the characteristics of supercapacitor were studied. The charge/discharge efficiency and the lifetime of the composite electrodes were also investigated. It was found that the composite electrodes exhibited more favorable capacitance properties than those of the carbon electrodes at high scan rates. The results revealed the promotion of the capacitance property of the supercapacitor with composite electrode and the improving of the decay property in capacitance at high scan rate. In addition, the charge/discharge efficiency is close to 100% after 5000 cycles, and the composite electrode retains strong adhesion between the electrode material and the substrate.

  10. Ion-selective electrode reviews

    CERN Document Server

    Thomas, J D R

    1983-01-01

    Ion-Selective Electrode Reviews, Volume 5 is a collection of articles that covers ion-speciation. The book aims to present the advancements of the range and capabilities of selective ion-sensors. The topics covered in the selection are neutral carrier based ion-selective electrodes; reference electrodes and liquid junction effects in ion-selective electrode potentiometry; ion transfer across water/organic phase boundaries and analytical; and carbon substrate ion-selective electrodes. The text will be of great use to chemists and chemical engineers.

  11. Direct measurement of lithium transport in graphite electrodes using neutrons

    International Nuclear Information System (INIS)

    Owejan, Jon P.; Gagliardo, Jeffrey J.; Harris, Stephen J.; Wang, Howard; Hussey, Daniel S.; Jacobson, David L.

    2012-01-01

    Highlights: ► Spatiotemporal measurements of lithium through the electrode thickness were quantified with high resolution neutron imaging. ► A nonuniform lithium distribution was observed early in the first intercalation cycle but relaxed as the electrode filled with lithium. ► Through-plane transport resistance in the bulk of the graphite composite electrode was measured. ► The distribution of lost capacity associated with trapped lithium was quantified and linked to regions with low intercalation rates. - Abstract: Lithium intercalation into graphite electrodes is widely studied, but few direct in situ diagnostic methods exist. Such diagnostic methods are desired to probe the influence of factors such as charge rate, electrode structure and solid electrolyte interphase layer transport resistance as they relate to lithium-ion battery performance and durability. In this work, we present a continuous measurement of through-plane lithium distributions in a composite graphite/lithium metal electrochemical cell. Capacity change in a thick graphite electrode was measured during several charge/discharge cycles with high resolution (14 μm) neutron imaging. A custom test fixture and a method for quantifying lithium are described. The measured lithium distribution within the graphite electrode is given as a function of state of charge. Bulk transport resistance is considered by comparing intercalation rates through the thickness of the electrode near the separator and current collector. The residual lithium content associated with irreversible capacity loss that results from cycling is also measured.

  12. Researches on Position Detection for Vacuum Switch Electrode

    Science.gov (United States)

    Dong, Huajun; Guo, Yingjie; Li, Jie; Kong, Yihan

    2018-03-01

    Form and transformation character of vacuum arc is important influencing factor on the vacuum switch performance, and the dynamic separations of electrode is the chief effecting factor on the transformation of vacuum arcs forms. Consequently, how to detect the position of electrode to calculate the separations in the arcs image is of great significance. However, gray level distribution of vacuum arcs image isn’t even, the gray level of burning arcs is high, but the gray level of electrode is low, meanwhile, the forms of vacuum arcs changes sharply, the problems above restrict electrode position detection precisely. In this paper, algorithm of detecting electrode position base on vacuum arcs image was proposed. The digital image processing technology was used in vacuum switch arcs image analysis, the upper edge and lower edge were detected respectively, then linear fitting was done using the result of edge detection, the fitting result was the position of electrode, thus, accurate position detection of electrode was realized. From the experimental results, we can see that: algorithm described in this paper detected upper and lower edge of arcs successfully and the position of electrode was obtained through calculation.

  13. Electrostatic Levitator Electrode Layout

    Science.gov (United States)

    1998-01-01

    Schematic of Electrostatic Levitator (ESL) electrodes and controls system. The ESL uses static electricity to suspend an object (about 2-3 mm in diameter) inside a vacuum chamber while a laser heats the sample until it melts. This lets scientists record a wide range of physical properties without the sample contacting the container or any instruments, conditions that would alter the readings. The Electrostatic Levitator is one of several tools used in NASA's microgravity materials science program.

  14. Flexible transparent electrode

    Science.gov (United States)

    Demiryont, Hulya; Shannon, Kenneth C., III; Moorehead, David; Bratcher, Matthew

    2011-06-01

    This paper presents the properties of the EclipseTECTM transparent conductor. EclipseTECTM is a room temperature deposited nanostructured thin film coating system comprised of metal-oxide semiconductor elements. The system possesses metal-like conductivity and glass-like transparency in the visible region. These highly conductive TEC films exhibit high shielding efficiency (35dB at 1 to 100GHz). EclipseTECTM can be deposited on rigid or flexible substrates. For example, EclipseTECTM deposited on polyethylene terephthalate (PET) is extremely flexible that can be rolled around a 9mm diameter cylinder with little or no reduction in electrical conductivity and that can assume pre-extension states after an applied stress is relieved. The TEC is colorless and has been tailored to have high visible transmittance which matches the eye sensitivity curve and allows the viewing of true background colors through the coating. EclipseTECTM is flexible, durable and can be tailored at the interface for applications such as electron- or hole-injecting OLED electrodes as well as electrodes in flexible displays. Tunable work function and optical design flexibility also make EclipseTECTM well-suited as a candidate for grid electrode replacement in next-generation photovoltaic cells.

  15. Atmospheric Pressure Glow Discharge with Liquid Electrode

    Science.gov (United States)

    Tochikubo, Fumiyoshi

    2013-09-01

    Nonthermal atmospheric pressure plasmas in contact with liquid are widely studied aiming variety of plasma applications. DC glow discharge with liquid electrode is an easy method to obtain simple and stable plasma-liquid interface. When we focus attention on liquid-phase reaction, the discharge system is considered as electrolysis with plasma electrode. The plasma electrode will supply electrons and positive ions to the liquid surface in a different way from the conventional metal electrode. However, the phenomena at plasma-liquid interface have not been understood well. In this work, we studied physical and chemical effect in liquid induced by dc atmospheric pressure glow discharge with liquid electrode. The experiment was carried out using H-shaped Hoffman electrolysis apparatus filled with electrolyte, to separate the anodic and cathodic reactions. Two nozzle electrodes made of stainless steel are set about 2 mm above the liquid surface. By applying a dc voltage between the nozzle electrodes, dc glow discharges as plasma electrodes are generated in contact with liquid. As electrolyte, we used aqueous solutions of NaCl, Na2SO4, AgNO3 and HAuCl4. AgNO3 and HAuCl4 are to discuss the reduction process of metal ions for synthesis of nanoparticles (NPs). OH radical generation yield in liquid was measured by chemical probe method using terephthalic acid. Discharge-induced liquid flow was visualized by Schlieren method. Electron irradiation to liquid surface (plasma cathode) generated OH- and OH radical in liquid while positive ion irradiation (plasma anode) generated H+ and OH radical. The generation efficiency of OH radical was better with plasma anode. Both Ag NPs in AgNO3 and Au NPs in HAuCl4 were synthesized with plasma cathode while only Au NPs were generated with plasma anode. Possible reaction process is qualitatively discussed. The discharge-induced liquid flow such as convection pattern was strongly influenced by the gas flow on the liquid surface. This work

  16. Stabilization of cadmium electrode properties when introducing surfactants

    International Nuclear Information System (INIS)

    Alekseeva, M.E.; Mansurov, F.Kh.; Nikol'skij, V.A.

    1995-01-01

    The results of tests of both separate cadmium electrodes and silver-cadmium accumulators, depending on introduction of surfactants (polyethylene oxide - PO - and its derivatives), have been considered. The influence of PO on the course of electrochemical reaction on cadmium is pronounced in facilitation of anodic process. In case of PO introduction in the amount of 1 % instead of sodium lignosulfonate (2 %) into accumulators with silver-cadmium electrodes, the electrode potential is stabilized, while the accumulator capacity increases. The time period of the accumulation maintenance in the charged state increases 2-3 fold (1-1,5 years). 5 refs.; 4 figs.; 2 tabs

  17. Electrodes for bio-application: recording and stimulation

    International Nuclear Information System (INIS)

    Fontes, M B A

    2013-01-01

    Recording and stimulation electrodes applied on excitable tissue are the basis of electrophysiological research, such as brain, muscles, peripheral nerves or sensory systems. Electrode-electrolyte impedance is one of the important characteristics due to its influence on the signal/noise ratio, signal distortion and built-up voltage. Strategies to lowering and tuning the impedance are achieved by biasing iridium oxide modified platinum microelectrodes. Surface and impedance analysis after pulse stimulation are also addressed.

  18. Characterization of Carbon Film Electrodes for Electroanalysis by Electrochemical Impedance

    OpenAIRE

    Filipe, Olga M. S.; Brett, Christopher M. A.

    2004-01-01

    The interfacial behavior of electrodes fabricated from carbon film resistors of 2 and 20 Omega in supporting electrolyte solutions of varying pH used in electroanalytical experiments has been characterized by electrochemical impedance spectroscopy with complementary cyclic voltammetric experiments. Equivalent circuits are proposed to fit the experimental data and the influence of electrode pretreatment has also been investigated. http://dx.doi.org/10.1002/elan.200402911

  19. Transparent Electrodes for Efficient Optoelectronics

    KAUST Repository

    Morales-Masis, Monica

    2017-03-30

    With the development of new generations of optoelectronic devices that combine high performance and novel functionalities (e.g., flexibility/bendability, adaptability, semi or full transparency), several classes of transparent electrodes have been developed in recent years. These range from optimized transparent conductive oxides (TCOs), which are historically the most commonly used transparent electrodes, to new electrodes made from nano- and 2D materials (e.g., metal nanowire networks and graphene), and to hybrid electrodes that integrate TCOs or dielectrics with nanowires, metal grids, or ultrathin metal films. Here, the most relevant transparent electrodes developed to date are introduced, their fundamental properties are described, and their materials are classified according to specific application requirements in high efficiency solar cells and flexible organic light-emitting diodes (OLEDs). This information serves as a guideline for selecting and developing appropriate transparent electrodes according to intended application requirements and functionality.

  20. Steel Collet For Welding Electrodes

    Science.gov (United States)

    Gilbert, Jeffrey L.; Gutow, David A.; Burley, Richard K.; Fogul, Irving

    1992-01-01

    Improved steel collet holds electrode for tungsten inert-gas welding but allows quick and easy replacement. Also ensures reliable arc starting. Slip-on compression ring compresses tapered section of body of collet around inner end of welding electrode. Collet mounted in receptacle below stack of lenses and filters in coaxial-vision welding torch. Blind hole in collet protects outermost lens from damage by electrode.

  1. A mercury free electrode for anodic stripping voltammetric determination of Pb (II) ions using poly zincon film modified electrode

    Science.gov (United States)

    Vasanthi, S.; Devendiran, M.; Narayanan, S. Sriman

    2017-11-01

    With an aim of developing a mercury-free electrode for anodic stripping voltammetric determination of Pb (II) ions, a poly zincon film (PZF) modified electrode is reported here. The PZF on the electrode surface has been obtained by electropolymerisation of zincon. PZF present on the electrode surface has been used for preconcentrating Pb (II) ions through complexation. The electrochemical determination of the above metal ion has been carried out by reducing the preconcentrated Pb (II) at -1.0 V followed by anodic stripping in acetate buffer of pH 6 and measuring the stripping current at -0.64 V. The PZF and Pb preconcentrated PZF modified electrodes have been characterized by scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The factors influencing the determination of Pb (II) ions such as the nature of medium/background electrolyte, pH, preconcentration time and electrode regeneration have been studied in detail. Under optimum conditions, a linear relation for the stripping current with Pb (II) ions in the solution has been observed in the range from 3.45 to 136.3 μg L-1 with a detection limit of 0.98 μg L-1. The regeneration of the modified electrode after each experiment has been achieved by simply immersing the electrode in 0.1 M EDTA solution for 2 min and washing thoroughly in de-ionised water. PZF modified electrode has shown a promising and sensitive platform for the anodic stripping determination of Pb (II) ions and the regeneration of the electrode has been found to be easy for subsequent uses. The proposed method has been applied for the determination of Pb (II) ions in ground water and tap water samples.

  2. Ion-selective electrode reviews

    CERN Document Server

    Thomas, J D R

    1982-01-01

    Ion-Selective Electrode Reviews, Volume 3, provides a review of articles on ion-selective electrodes (ISEs). The volume begins with an article on methods based on titration procedures for surfactant analysis, which have been developed for discrete batch operation and for continuous AutoAnalyser use. Separate chapters deal with detection limits of ion-selective electrodes; the possibility of using inorganic ion-exchange materials as ion-sensors; and the effect of solvent on potentials of cells with ion-selective electrodes. Also included is a chapter on advances in calibration procedures, the d

  3. Coated carbon nanotube array electrodes

    Science.gov (United States)

    Ren, Zhifeng [Newton, MA; Wen, Jian [Newton, MA; Chen, Jinghua [Chestnut Hill, MA; Huang, Zhongping [Belmont, MA; Wang, Dezhi [Wellesley, MA

    2008-10-28

    The present invention provides conductive carbon nanotube (CNT) electrode materials comprising aligned CNT substrates coated with an electrically conducting polymer, and the fabrication of electrodes for use in high performance electrical energy storage devices. In particular, the present invention provides conductive CNTs electrode material whose electrical properties render them especially suitable for use in high efficiency rechargeable batteries. The present invention also provides methods for obtaining surface modified conductive CNT electrode materials comprising an array of individual linear, aligned CNTs having a uniform surface coating of an electrically conductive polymer such as polypyrrole, and their use in electrical energy storage devices.

  4. Quantitative Microstructure Characterization of a NMC Electrode

    Energy Technology Data Exchange (ETDEWEB)

    Usseglio Viretta, Francois L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Smith, Kandler A [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-09-28

    Performance of lithium-ion batteries (LIBs) is strongly influenced by the porous microstructure of their electrodes. In this work, 3D microstructures of calendared and un-calendared positive electrode LiNi1/3Mn1/3Co1/3O2 (NMC) have been investigated in order to extract relevant properties useful for battery modeling. Transport (volume fraction, connectivity, particle size and tortuosity) and electrochemical (specific surface area) properties have been calculated for the pore and the active material. Special attention has been paid to determine the size of the so-called representative volume element (RVE) required to be statistically representative of the heterogeneous medium. Several parameters have been calculated using a panel of different numerical methods in order to compare their results. Besides, the image level of detail has been evaluated (using original criteria based upon edge detection) to assess the overall data quality available for the study.

  5. Electrochemical properties of polypyrrole/polyfuran polymer composite electrode

    International Nuclear Information System (INIS)

    Cha, Seong Keuck

    1998-01-01

    Poly pyrrole polymer(ppy) has an excellent electrical conductivity and can be easily polymerized on anode to give various morphology according to doped anion on electroactive sites. To improve the properties of brittleness, ageing and hydrophobicity, poly furan polymer(pfu) having a high initiation potential was anodically implanted in this porous ppy film matrix to get the Pt/ppy/pfu(x)type of polymer campsite electrode. Cyclic voltammetry and electrochemical impedance methods were used to these electrode, where PF 6 - , BF 4 - , and ClO 4 - ions were employed as dopants. The composition of the pfu(x) at the electrode was changed from 0 to 1.10, but the range was useful only at 0.1 to 0.2 as the redox electrode. The polymer composite electrode doped with PF 6 - was better in charge transfer resistance by a factor of 40 times and in double layer capacitance by a factor of 20 times than others. The charge transfer in the polymer film of the electrode was influenced on frequency change and equivalent circuit of this electrode had Warburg impedance including mass transfer

  6. Gas sensor with multiple internal reference electrodes and sensing electrodes

    DEFF Research Database (Denmark)

    2016-01-01

    The invention relates to a potentiometric gas sensor, or potentiometric gas detection element, with multiple internal reference electrodes and multiple sensing electrodes for determining the concentrations of gas components in a gaseous mixture. The sensor for gas detection comprises: a solid...

  7. Secondary-Phase Stochastics in Lithium-Ion Battery Electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Kandler A [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Mistry, Aashutosh N. [Purdue University; Mukherjee, Partha P. [Purdue University

    2018-01-12

    Lithium-ion battery electrodes exhibit complex interplay among multiple electrochemically coupled transport processes, which rely on the underlying functionality and relative arrangement of different constituent phases. The electrochemically inactive solid phases (e.g., conductive additive and binder, referred to as the secondary phase), while beneficial for improved electronic conductivity and mechanical integrity, may partially block the electrochemically active sites and introduce additional transport resistances in the pore (electrolyte) phase. In this work, the role of mesoscale interactions and inherent stochasticity in porous electrodes is elucidated in the context of short-range (interface) and long-range (transport) characteristics. The electrode microstructure significantly affects kinetically and transport-limiting scenarios and thereby the cell performance. The secondary-phase morphology is also found to strongly influence the microstructure-transport-kinetics interactions. Apropos, strategies have been proposed for performance improvement via electrode microstructural modifications.

  8. Electrode Kinetics and Gas Conversion in Solid Oxide Cells

    DEFF Research Database (Denmark)

    Njodzefon, Jean-Claude

    that the kinetics at the fuel electrode were exactly the same in both reformates. This means that chemical equilibrium reactions were much faster than the electrochemical reactions. The electrode displayed slightly faster kinetics in hydrogen/steam fuel than in the reformate fuels. To minimize the influence of (i...... slower reaction kinetics under cathodic mode operation at 50 mV overvoltage than in anodic mode. The trend was opposite for the lower performing La0.58Sr0.4Co0.2Fe0.8O3 (LSCF) oxygen electrode. However, with decreasing oxygen partial pressure both electrodes displayed increasing asymmetry between anodic...... and cathodic modes. It could be shown that surface exchange kinetics were the major cause of the decreasing kinetics with decreasing pO2 and that the cathodic mode kinetics were slowed down much more than the anodic branch kinetics thus increasing the asymmetry. Independent of operation mode, commercialization...

  9. Electrode materials for microbial fuel cells: nanomaterial approach

    KAUST Repository

    Mustakeem, Mustakeem

    2015-11-05

    Microbial fuel cell (MFC) technology has the potential to become a major renewable energy resource by degrading organic pollutants in wastewater. The performance of MFC directly depends on the kinetics of the electrode reactions within the fuel cell, with the performance of the electrodes heavily influenced by the materials they are made from. A wide range of materials have been tested to improve the performance of MFCs. In the past decade, carbon-based nanomaterials have emerged as promising materials for both anode and cathode construction. Composite materials have also shown to have the potential to become materials of choice for electrode manufacture. Various transition metal oxides have been investigated as alternatives to conventional expensive metals like platinum for oxygen reduction reaction. In this review, different carbon-based nanomaterials and composite materials are discussed for their potential use as MFC electrodes.

  10. Light addressable gold electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Khalid, Waqas

    2011-07-01

    The main objective carried out in this dissertation was to fabricate Light Amplified Potentiometric sensors (LAPS) based upon the semiconductor nanoparticles (quantum dots) instead of its bulk form. Quantum dots (QDs) were opted for this device fabrication because of their superior fluorescent, electric and catalytic properties. Also in comparison to their bulk counterparts they will make device small, light weighted and power consumption is much lower. QDs were immobilized on a Au substrate via 1,4 benzene dithiol (BDT) molecule. Initially a self-assembled monolayer (SAM) of BDT was established on Au substrate. Because of SAM, the conductivity of Au substrate decreased dramatically. Furthermore QDs were anchored with the help of BDT molecule on Au substrate. When QDs immobilized on Au substrate (QD/Au) via BDT molecule were irradiated with UV-visible light, electron-hole pairs were generated in QDs. The surface defect states in QDs trapped the excited electrons and long lived electron-hole pairs were formed. By the application of an appropriate bias potential on Au substrate the electrons could be supplied or extracted from the QDs via tunneling through BDT. Thus a cathodic or anodic current could be observed depending upon bias potential under illumination. However without light illumination the QD/Au electrode remained an insulator. To improve the device different modifications were made, including different substrates (Au evaporated on glass, Au evaporated on mica sheets and Au sputtered on SiO{sub 2}/Si) and different dithiol molecules (capped and uncapped biphenyl 4,4' dithiol and capped and uncapped 4,4' dimercaptostilbenes) were tried. Also different QD immobilization techniques (normal incubation, spin coating, layer by layer assembly (LbL) of polyelectrolytes and heat immobilization) were employed. This device was able to detect electrochemically different analytes depending upon the QDs incorporated. For example CdS QDs were able to detect 4

  11. Study on Carbon Nano composite Counter electrode for Dye-Sensitized Solar Cells

    International Nuclear Information System (INIS)

    Chen, Y.; Zhang, H.; Lin, J.

    2012-01-01

    Carbon nano composite electrodes were prepared by adding carbon nano tubes (CNTs) into carbon black as counter electrodes of dye-sensitized solar cells (DSSCs). The morphology and structure of carbon nano composite electrodes were studied by scanning electron microscopy. The influence of CNTs on the electrochemical performance of carbon nano composite electrodes is investigated by cyclic voltammetry and electrochemical impedance spectroscopy. Carbon nano composite electrodes with CNTs exhibit a highly interconnected network structure with high electrical conductivity and good catalytic activity. The influence of different CNTs content in carbon nano composite electrodes on the open-circuit voltage, short-circuit current, and filling factor of DSSCs is also investigated. DSSCs with 10% CNTs content exhibit the best photovoltaic performance in our experiments.

  12. ELECTROCHEMISTRY OF FUEL CELL ELECTRODES.

    Science.gov (United States)

    optimization of fuel cell electrodes. Hydrogen oxidation and reduction, the reduction of oxygen, and the oxidation of formic acid, a soluble organic...substance, were selected for these studiees because of their relevance to fuel cell systems and because of their relative simplicity. The electrodes

  13. Precordial electrode placement in women.

    Science.gov (United States)

    Macfarlane, P W; Colaco, R; Stevens, K; Reay, P; Beckett, C; Aitchison, T

    2003-03-01

    Precordial ECG electrode positioning was standardised in the early 1940s. However, it has been customary for the V 3 to V 6 electrodes to be placed under the left breast in women rather than in the correct anatomical positions relating to the 4th and 5th interspaces. For this reason, a comparison between the two approaches to chest electrode positioning in women was undertaken. In total 84 women were recruited and ECGs recorded with electrodes in the correct anatomical position and also in the more commonly used positions under the breast. As a separate study, 299 healthy women were recruited to study normal limits of leads V 3 to V 6 recorded with electrodes in the correct anatomical positions and compare them with published normal limits with electrodes in the more commonly used locations. It was shown that there was less variability with electrodes in the correct anatomical positions and that there were significant differences between the new limits of normality compared with the old established limits. Expansion of the database and further analysis of the data is required to make a definitive recommendation with respect to precordial electrode placement in women.

  14. EDM Electrode for Internal Grooves

    Science.gov (United States)

    Ramani, V.; Werner, A.

    1985-01-01

    Electroerosive process inexpensive alternative to broaching. Hollow brass electrodes, soldered at one end to stainless-steel holding ring, held in grooves in mandrel. These electrodes used to machine grooves electrically in stainless-steel tube three-eights inch (9.5 millimeters) in diameter. Tool used on tubes already in place in equipment.

  15. Making EDM Electrodes By Stereolithography

    Science.gov (United States)

    Barlas, Philip A.

    1988-01-01

    Stereolithography is computer-aided manufacturing technique. Used to make models and molds of electrodes for electrical-discharge machining (EDM). Eliminates intermediate steps in fabrication of plastic model of object used in making EDM electrode to manufacture object or mold for object.

  16. Multi electrode semiconductors detectors

    CERN Document Server

    Amendolia, S R; Bertolucci, Ennio; Bosisio, L; Bradaschia, C; Budinich, M; Fidecaro, F; Foà, L; Focardi, E; Giazotto, A; Giorgi, M A; Marrocchesi, P S; Menzione, A; Ristori, L; Rolandi, Luigi; Scribano, A; Stefanini, A; Vincelli, M L

    1981-01-01

    Detectors with very high space resolution have been built in this laboratory and tested at CERN in order to investigate their possible use in high energy physics experiments. These detectors consist of thin layers of silicon crystals acting as ionization chambers. Thin electrodes, structured in strips or in more fancy shapes are applied to their surfaces by metal coating. The space resolution which could be reached is of the order of a few microns. An interesting feature of these solid state detectors is that they can work under very high or low external pressure or at very low temperature. The use of these detectors would strongly reduce the dimensions and the cost of high energy experiments. (3 refs).

  17. Multi electrode semiconductor detectors

    International Nuclear Information System (INIS)

    Amendolia, S.R.; Batignani, G.; Bertolucci, E.; Bosisio, L.; Budinich, M.; Bradaschia, C.; Fidecaro, F.; Foa, L.; Focardi, E.; Giazotto, A.; Giorgi, M.A.; Marrocchesi, P.S.; Menzione, A.; Ristori, L.; Rolandi, L.; Scribano, A.; Stefanini, A.; Vincelli, M.L.

    1981-01-01

    Detectors with very high space resolution have been built in the laboratory and tested at CERN in order to investigate their possible use in high energy physics experiments. These detectors consist of thin layers of silicon crystals acting as ionization chambers. Thin electrodes, structured in strips or in more fancy shapes are applied to their surfaces by metal coating. The space resolution which could be reached is of the order of a few microns. An interesting feature of these solid state detectors is that they can work under very high or low external pressure or at very low temperature. The use of these detectors would strongly reduce the dimensions and the cost of high energy experiments. (Auth.)

  18. Low resistance electrode construction

    Science.gov (United States)

    Redey, Laszlo; Karell, Eric J.

    2002-01-01

    An electrochemical cell having a cathode and an anode in contact with an electrolyte. Both electrodes or one of them has an electrically conducting non-metal receptacle defining a chamber with a first metal having a melting point in the range of from about room temperature to about 800.degree. C. inside said receptacle chamber. A second metal with a melting point greater than about 800.degree. C. is in contact with the first metal inside the receptacle chamber and extends outside of the receptacle chamber to form a terminal for the anode. The electrolyte may include the oxides, halides or mixtures thereof of one or more of Li, V, U, Al and the lanthanides. Metal may be produced at the cathode during operation of the cell and oxygen or chlorine at the anode.

  19. Erosion on spark plug electrodes; Funkenerosion an Zuendkerzenelektroden

    Energy Technology Data Exchange (ETDEWEB)

    Rager, J.

    2006-07-01

    Durability of spark plugs is mainly determined by spark gap widening, caused by electrode wear. Knowledge about the erosion mechanisms of spark plug materials is of fundamental interest for the development of materials with a high resistance against electrode erosion. It is therefore crucial to identify those parameters which significantly influence the erosion behaviour of a material. In this work, a reliable and reproducible testing method is presented which produces and characterizes electrode wear under well-defined conditions and which is capable of altering parameters specifically. Endurance tests were carried out to study the dependence of the wear behaviour of pure nickel and platinum on the electrode temperature, gas, electrode gap, electrode diameter, atmospheric pressure, and partial pressure of oxygen. It was shown that erosion under nitrogen is negligible, irrespective of the material. This disproves all common mechanism discussed in the literature explaining material loss of spark plug electrodes. Based on this observation and the variation of the mentioned parameters a new erosion model was deduced. This relies on an oxidation of the electrode material and describes the erosion of nickel and platinum separately. For nickel, electrode wear is caused by the removal of an oxide layer by the spark. In the case of platinum, material loss occurs due to the plasma-assisted formation and subsequent evaporation of volatile oxides in the cathode spot. On the basis of this mechanism a new composite material was developed whose erosion resistance is superior to pure platinum. Oxidation resistant metal oxide particles were added to a platinum matrix, thus leading to a higher erosion resistance of the composite. However, this can be decreased by a side reaction, the separation of oxygen from the metal oxides, which effectively assists the oxidation of the matrix. This reaction can be suppressed by using highly stable oxides, characterized by a large negative Gibbs

  20. Organophosphonate biofunctionalization of diamond electrodes.

    Science.gov (United States)

    Caterino, R; Csiki, R; Wiesinger, M; Sachsenhauser, M; Stutzmann, M; Garrido, J A; Cattani-Scholz, A; Speranza, Giorgio; Janssens, S D; Haenen, K

    2014-08-27

    The modification of the diamond surface with organic molecules is a crucial aspect to be considered for any bioapplication of this material. There is great interest in broadening the range of linker molecules that can be covalently bound to the diamond surface. In the case of protein immobilization, the hydropathicity of the surface has a major influence on the protein conformation and, thus, on the functionality of proteins immobilized at surfaces. For electrochemical applications, particular attention has to be devoted to avoid that the charge transfer between the electrode and the redox center embedded in the protein is hindered by a thick insulating linker layer. This paper reports on the grafting of 6-phosphonohexanoic acid on OH-terminated diamond surfaces, serving as linkers to tether electroactive proteins onto diamond surfaces. X-ray photoelectron spectroscopy (XPS) confirms the formation of a stable layer on the surface. The charge transfer between electroactive molecules and the substrate is studied by electrochemical characterization of the redox activity of aminomethylferrocene and cytochrome c covalently bound to the substrate through this linker. Our work demonstrates that OH-terminated diamond functionalized with 6-phosphonohexanoic acid is a suitable platform to interface redox-proteins, which are fundamental building blocks for many bioelectronics applications.

  1. Electrode for a lithium cell

    Science.gov (United States)

    Thackeray, Michael M [Naperville, IL; Vaughey, John T [Elmhurst, IL; Dees, Dennis W [Downers Grove, IL

    2008-10-14

    This invention relates to a positive electrode for an electrochemical cell or battery, and to an electrochemical cell or battery; the invention relates more specifically to a positive electrode for a non-aqueous lithium cell or battery when the electrode is used therein. The positive electrode includes a composite metal oxide containing AgV.sub.3O.sub.8 as one component and one or more other components consisting of LiV.sub.3O.sub.8, Ag.sub.2V.sub.4O.sub.11, MnO.sub.2, CF.sub.x, AgF or Ag.sub.2O to increase the energy density of the cell, optionally in the presence of silver powder and/or silver foil to assist in current collection at the electrode and to improve the power capability of the cell or battery.

  2. Composite electrode/electrolyte structure

    Science.gov (United States)

    Visco, Steven J.; Jacobson, Craig P.; DeJonghe, Lutgard C.

    2004-01-27

    Provided is an electrode fabricated from highly electronically conductive materials such as metals, metal alloys, or electronically conductive ceramics. The electronic conductivity of the electrode substrate is maximized. Onto this electrode in the green state, a green ionic (e.g., electrolyte) film is deposited and the assembly is co-fired at a temperature suitable to fully densify the film while the substrate retains porosity. Subsequently, a catalytic material is added to the electrode structure by infiltration of a metal salt and subsequent low temperature firing. The invention allows for an electrode with high electronic conductivity and sufficient catalytic activity to achieve high power density in ionic (electrochemical) devices such as fuel cells and electrolytic gas separation systems.

  3. Advantage of four-electrode over two-electrode defibrillators

    Science.gov (United States)

    Bragard, J.; Šimić, A.; Laroze, D.; Elorza, J.

    2015-12-01

    Defibrillation is the standard clinical treatment used to stop ventricular fibrillation. An electrical device delivers a controlled amount of electrical energy via a pair of electrodes in order to reestablish a normal heart rate. We propose a technique that is a combination of biphasic shocks applied with a four-electrode system rather than the standard two-electrode system. We use a numerical model of a one-dimensional ring of cardiac tissue in order to test and evaluate the benefit of this technique. We compare three different shock protocols, namely a monophasic and two types of biphasic shocks. The results obtained by using a four-electrode system are compared quantitatively with those obtained with the standard two-electrode system. We find that a huge reduction in defibrillation threshold is achieved with the four-electrode system. For the most efficient protocol (asymmetric biphasic), we obtain a reduction in excess of 80% in the energy required for a defibrillation success rate of 90%. The mechanisms of successful defibrillation are also analyzed. This reveals that the advantage of asymmetric biphasic shocks with four electrodes lies in the duration of the cathodal and anodal phase of the shock.

  4. Assessing the Electrode-Neuron Interface with the Electrically Evoked Compound Action Potential, Electrode Position, and Behavioral Thresholds.

    Science.gov (United States)

    DeVries, Lindsay; Scheperle, Rachel; Bierer, Julie Arenberg

    2016-06-01

    Variability in speech perception scores among cochlear implant listeners may largely reflect the variable efficacy of implant electrodes to convey stimulus information to the auditory nerve. In the present study, three metrics were applied to assess the quality of the electrode-neuron interface of individual cochlear implant channels: the electrically evoked compound action potential (ECAP), the estimation of electrode position using computerized tomography (CT), and behavioral thresholds using focused stimulation. The primary motivation of this approach is to evaluate the ECAP as a site-specific measure of the electrode-neuron interface in the context of two peripheral factors that likely contribute to degraded perception: large electrode-to-modiolus distance and reduced neural density. Ten unilaterally implanted adults with Advanced Bionics HiRes90k devices participated. ECAPs were elicited with monopolar stimulation within a forward-masking paradigm to construct channel interaction functions (CIF), behavioral thresholds were obtained with quadrupolar (sQP) stimulation, and data from imaging provided estimates of electrode-to-modiolus distance and scalar location (scala tympani (ST), intermediate, or scala vestibuli (SV)) for each electrode. The width of the ECAP CIF was positively correlated with electrode-to-modiolus distance; both of these measures were also influenced by scalar position. The ECAP peak amplitude was negatively correlated with behavioral thresholds. Moreover, subjects with low behavioral thresholds and large ECAP amplitudes, averaged across electrodes, tended to have higher speech perception scores. These results suggest a potential clinical role for the ECAP in the objective assessment of individual cochlear implant channels, with the potential to improve speech perception outcomes.

  5. Cochlear Dummy Electrodes for Insertion Training and Research Purposes: Fabrication, Mechanical Characterization, and Experimental Validation

    Directory of Open Access Journals (Sweden)

    Jan-Philipp Kobler

    2015-01-01

    Full Text Available To develop skills sufficient for hearing preservation cochlear implant surgery, surgeons need to perform several electrode insertion trials in ex vivo temporal bones, thereby consuming relatively expensive electrode carriers. The objectives of this study were to evaluate the insertion characteristics of cochlear electrodes in a plastic scala tympani model and to fabricate radio opaque polymer filament dummy electrodes of equivalent mechanical properties. In addition, this study should aid the design and development of new cochlear electrodes. Automated insertion force measurement is a new technique to reproducibly analyze and evaluate the insertion dynamics and mechanical characteristics of an electrode. Mechanical properties of MED-EL’s FLEX28, FLEX24, and FLEX20 electrodes were assessed with the help of an automated insertion tool. Statistical analysis of the overall mechanical behavior of the electrodes and factors influencing the insertion force are discussed. Radio opaque dummy electrodes of comparable characteristics were fabricated based on insertion force measurements. The platinum-iridium wires were replaced by polymer filament to provide sufficient stiffness to the electrodes and to eradicate the metallic artifacts in X-ray and computed tomography (CT images. These low-cost dummy electrodes are cheap alternatives for surgical training and for in vitro, ex vivo, and in vivo research purposes.

  6. Noise properties of textile, capacitive EEG electrodes

    OpenAIRE

    Asl Sara Nazari; Ludwig Frank; Schilling Meinhard

    2015-01-01

    The rigid surface of the conventional PCB-based capacitive electrode produces an undefined distance between the skin and the electrode surface. Therefore, the capacitance introduced by them is uncertain and can vary from electrode to electrode due to their different positions on the scalp. However, textile electrodes which use conductive fabric as electrode surfaces, are bendable over the scalp. Therefore, it provides a certain value of the capacitance which is predictable and calculable accu...

  7. Preset Electrodes for Electrical-Discharge Machining

    Science.gov (United States)

    Coker, Bill E.

    1987-01-01

    New electrode holder for electrical-discharge machining (EDM) provides for repeatable loading and setting of many electrodes. New holder is rotating-index tool carrying six, eight, or more electrodes. Before use, all electrodes set with aid of ring surrounding tool, and locked in position with screws. When electrode replaced, EDM operator pulls spring-loaded pin on tool so it rotates about center pin. Fresh electrode then rotated into position against workpiece.

  8. Ammonium ions determination with polypyrrole modified electrode

    Directory of Open Access Journals (Sweden)

    Luiz Henrique Dall´Antonia

    2007-03-01

    Full Text Available The present work relates the preparation of polypyrrole films (PPy deposited on surfaces of glass carbon, nickel and ITO (tin oxide doped with indium on PET plastic, in order to study the ammonium detection. The popypyrrole films were polymerized with dodecylbenzenesulfonate (DBSA on the electrodes, at + 0,70 V vs. Ag/AgCl, based on a solution containing the pyrrole monomer and the amphiphilic salt. Films deposited on glass carbon presented better performance. Cyclic voltammetries, between – 1,50 to + 0,5 V vs. Ag/AgCl, were repeated adding different concentrations of NH4Cl, in order to observe the behavior of the film as a possible detector of ions NH4+. The peak current for oxidation varies with the concentration of ammonium. A linear region can be observed in the band of 0 to 80 mM, with a sensibility (Sppy approximately similar to 4,2 mA mM-1 cm-2, showing the efficacy of the electrodes as sensors of ammonium ions. The amount of deposited polymer, controlled by the time of growth, does not influence on the sensor sensibility. The modified electrode was used to determine ammonium in grounded waters.

  9. ELECTROD FLUOR-SELECTIV

    Directory of Open Access Journals (Sweden)

    Mariana DÎRU

    2018-03-01

    Full Text Available A fost preparat un senzor anionic specific, bazat pe pivalatul trinuclear al cromului(III ca material electro­activ încorporat în membrana PVC plastifiată. Senzorul prezintă răspuns Nernstian (55,78 mV/decadă în intervalul de concentrație 10-1-10-4 mol/L cu limita de detecție 2,0∙10-5 mol/L pentru anionul fluorură. Domeniul optim de pH de funcţionare a electrodului asamblat este ˃5. Senzorul dat are un timp de răspuns de 30-60 s și reproductibilitatea rezultatelor se menține timp de 3 luni. Coeficienții potențiometrici ai selectivității au fost determinați prin metoda soluțiilor separate. A fost realizată aplicarea acestor electrozi la analiza pastei de dinți ce conține fluorură și rezultatele experimentale au fost comparate cu datele de pe prospect.FLUORIDE-SELECTIVE ELECTRODEA specific anionic sensor has been prepared, based on trinuclearchromium(III pivalate as sensing material incorpo­rated into the plasticized PVC-membrane. The sensor exhibited Nernstian response (55,78 mV/decade in the region between 10-1-10-4 mol/L with a detection limit of 2,0∙10-5 mol/L for fluoride. The working pH of the electrode was in the 5-6 range. The sensor has a response time 30-60 s and can be used for least 3 month. The potentiometric selectivity coefficients were determined by separate solution method. Application of these electrodes to the analysis of toothpaste containing fluoride has been realized and experimental results have been compared with the data on the prospectus.

  10. New electrodes for biofuel cells

    Science.gov (United States)

    Stom, D. I.; Zhdanova, G. O.; Lashin, A. F.

    2017-11-01

    Two new types of electrodes for biofuel elements (BFC) are proposed. One of them is based on a microchannel plate (MCP). Its peculiarity is a special structure with a large number of glass channels being 6-10 μm in diameter with an internal semiconducting surface. The MCP operation is based on the principle of the channel secondary emission multiplication of the electrons. The second type of electrode presented in the work is made of silicon carbide. This type of electrodes has a developed porous structure. The electrode pores account for at least 30% of the total volume. The pore size varies from 10 to 100 μm. Such porosity greatly increases the anode area and volume. This allows us to achieve sorption of a larger number of microorganisms interacting with the anode and transformed by electron donors. The work of the electrodes developed in BFC was tested, their effectiveness was estimated. A comparison is made with electrodes made of carbon cloth, the most widely used material for working with BFC. It is shown that the MCP based electrode is not inferior to the power characteristics of carbon cloth. The generated power when using silicon carbide was slightly lower than the other two electrodes. However, the stability of silicon carbide to aggressive media (alkalis, acids, strong oxidants, etc.), as well as to mechanical damages gives additional advantages to such electrodes compared to the materials that are commonly used in BFC. The noted features are extremely important for the BFC to work in harsh conditions of treatment facilities and to utilize wastewater components.

  11. Interdigitated electrodes as impedance and capacitance biosensors: A review

    Science.gov (United States)

    Mazlan, N. S.; Ramli, M. M.; Abdullah, M. M. A. B.; Halin, D. S. C.; Isa, S. S. M.; Talip, L. F. A.; Danial, N. S.; Murad, S. A. Z.

    2017-09-01

    Interdigitated electrodes (IDEs) are made of two individually addressable interdigitated comb-like electrode structures. IDEs are one of the most favored transducers, widely utilized in technological applications especially in the field of biological and chemical sensors due to their inexpensive, ease of fabrication process and high sensitivity. In order to detect and analyze a biochemical molecule or analyte, the impedance and capacitance signal need to be obtained. This paper investigates the working principle and influencer of the impedance and capacitance biosensors. The impedance biosensor depends on the resistance and capacitance while the capacitance biosensor influenced by the dielectric permittivity. However, the geometry and structures of the interdigitated electrodes affect both impedance and capacitance biosensor. The details have been discussed in this paper.

  12. Studies of pyrrole black electrodes as possible battery positive electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Mengoli, G.; Musiani, M.M.; Fleischmann, M.; Pletcher, D.

    1984-05-01

    It is shown that a polypyrrole, pyrrole black, may be formed anodically in several aqueous acids. The polypyrrole film shows a redox couple at less positive potentials than that required to form the film and the charge associated with these reduction and oxidation processes together with their stabilty to cycling varies with the anion in solution and the potential where the polypyrrole is formed; over-oxidation of the film caused by taking its potential too positive has a particularly disadvantageous affect. In the acids HBr and HI, the polypyrrole films can act as a storage medium for Br/sub 2/ or I/sub 2/ so that they may be used as a substrate for a X/sub 2//X/sup -/ electrode. Such electrodes may be charge/discharge cycled and the pyrrole/Br/sub 2/ electrode shows promise as a battery positive electrode.

  13. Protrusion of the Rod Electrode in the Electrospinning Process

    Directory of Open Access Journals (Sweden)

    Jan Valtera

    2015-01-01

    Full Text Available The paper focuses on the influence of the protrusion of the rod electrode on critical voltage in the DC electrospinning process. On the testing and industrial DC electrospinning devices, electrodes of any kind are extended towards the counter electrode. This provides the maximal, that is, supercritical, electric field intensity on the spinning-electrode orifice that is found to be higher than on the other supplementary parts. The principal study and experiments with basic apparatus were carried out and presented by Taylor in 1966. This study is focused on the arrangement closely related to the design of the real electrospinning device with respect to the safety and technological aspects. Results of the carried out experiments of the rod spinning-electrode are compared with the electrostatic simulation and analytical calculation. The presented effect of the electrode protrusion on the potential difference and the critical field strength introduces valuable information for the designers of electrospinning machines as well as for the setting up of the optimal technological parameters for producing modern nonwoven textile products.

  14. Protrusion of the Rod Electrode in the Electro spinning Process

    International Nuclear Information System (INIS)

    Valtera, J.; Komarek, J.; Skrivanek, J.; Zabka, P.; Beran, J.; Vyslouzilova, L.; Lukas, D.

    2015-01-01

    The paper focuses on the influence of the protrusion of the rod electrode on critical voltage in the DC electro spinning process. On the testing and industrial DC electro spinning devices, electrodes of any kind are extended towards the counter electrode. This provides the maximal, that is, supercritical, electric field intensity on the spinning-electrode orifice that is found to be higher than on the other supplementary parts. The principal study and experiments with basic apparatus were carried out and presented by Taylor in 1966. This study is focused on the arrangement closely related to the design of the real electro spinning device with respect to the safety and technological aspects. Results of the carried out experiments of the rod spinning-electrode are compared with the electrostatic simulation and analytical calculation. The presented effect of the electrode protrusion on the potential difference and the critical field strength introduces valuable information for the designers of electro spinning machines as well as for the setting up of the optimal technological parameters for producing modern nonwoven textile products.

  15. Counter electrodes in dye-sensitized solar cells.

    Science.gov (United States)

    Wu, Jihuai; Lan, Zhang; Lin, Jianming; Huang, Miaoliang; Huang, Yunfang; Fan, Leqing; Luo, Genggeng; Lin, Yu; Xie, Yimin; Wei, Yuelin

    2017-10-02

    Dye-sensitized solar cells (DSSCs) are regarded as prospective solar cells for the next generation of photovoltaic technologies and have become research hotspots in the PV field. The counter electrode, as a crucial component of DSSCs, collects electrons from the external circuit and catalyzes the redox reduction in the electrolyte, which has a significant influence on the photovoltaic performance, long-term stability and cost of the devices. Solar cells, dye-sensitized solar cells, as well as the structure, principle, preparation and characterization of counter electrodes are mentioned in the introduction section. The next six sections discuss the counter electrodes based on transparency and flexibility, metals and alloys, carbon materials, conductive polymers, transition metal compounds, and hybrids, respectively. The special features and performance, advantages and disadvantages, preparation, characterization, mechanisms, important events and development histories of various counter electrodes are presented. In the eighth section, the development of counter electrodes is summarized with an outlook. This article panoramically reviews the counter electrodes in DSSCs, which is of great significance for enhancing the development levels of DSSCs and other photoelectrochemical devices.

  16. Connecting electrodes with light: one wire, many electrodes.

    Science.gov (United States)

    Choudhury, Moinul H; Ciampi, Simone; Yang, Ying; Tavallaie, Roya; Zhu, Ying; Zarei, Leila; Gonçales, Vinicius R; Gooding, J Justin

    2015-12-01

    The requirement of a wire to each electrode is central to the design of any electronic device but can also be a major restriction. For example it entails space restrictions and rigid device architecture in multi-electrode devices. The finite space that is taken up by the array of electrical terminals and conductive pads also severely limits the achievable density of electrodes in the device. Here it is shown that a travelling light pointer can be used to form transient electrical connections anywhere on a monolithic semiconductor electrode that is fitted with a single peripheral electrical terminal. This is achieved using hydrogen terminated silicon electrodes that are modified with well-defined organic monolayers. It is shown that electrochemical information can be either read from or written onto these surfaces. Using this concept it is possible to form devices that are equivalent to a conventional electrode array but that do not require a predetermined architecture, and where each element of the array is temporally "connected" using light stimulus; a step change in capability for electrochemistry.

  17. A viable electrode material for use in microbial fuel cells for tropical regions

    DEFF Research Database (Denmark)

    Offei, Felix; Thygesen, Anders; Mensah, Moses

    2016-01-01

    Electrode materials are critical for microbial fuel cells (MFC) since they influence the construction and operational costs. This study introduces a simple and efficient electrode material in the form of palm kernel shell activated carbon (AC) obtained in tropical regions. The novel introduction ...

  18. Electroenzymatic Reactions With Oxygen on Laccase-Modified Electrodes in Anhydrous (Pure) Organic Solvent

    DEFF Research Database (Denmark)

    Yarapolov, A.; Shleev, S.; Zaitseva, E.

    2007-01-01

    glassy carbon and graphite electrodes with adsorbed laccase. The influence of the time for drying the laccase solution at the electrode surface on the electroreduction of oxygen was studied. Investigating the electroenzymatic oxidation reaction of catechol and hydroquinone in DMSO reveals the formation...

  19. Nickel foam/polyaniline-based carbon/palladium composite electrodes for hydrogen storage

    International Nuclear Information System (INIS)

    Skowronski, Jan M.; Urbaniak, Jan

    2008-01-01

    The sandwich-like nickel/palladium/carbon electrodes exhibiting ability to absorb hydrogen in alkaline solution are presented. Electrodes were prepared by successive deposition of palladium and polyaniline layers on nickel foam substrate followed by heat treatment to give Ni/Pd/C electrode. It was shown that thermal conversion of polymer into carbon layer and subsequent thermal activation of carbon component bring about the modification of the mechanism of reversible hydrogen sorption. It was proven that carbon layer, interacting with Pd catalyst, plays a considerable role in the process of hydrogen storage. In the other series of experiments, Pd particles were dispersed electrochemically on carbon coating leading to Ni/C/Pd system. The adding of the next carbon layer resulted in Ni/C/Pd/C electrodes. Electrochemical properties of the electrodes depend on both the sequence of Pd and C layers and the preparation/activation of carbon coating. Electrochemical behavior of sandwich-like electrodes in the reaction of hydrogen sorption/desorption was characterized in 6 M KOH using the cyclic voltammetry method and the results obtained were compared to those for Ni/Pd electrode. The anodic desorption of hydrogen from electrodes free and containing carbon layer was considered after the potentiodynamic as well as potentiostatic sorption of hydrogen. The influence of the sorption potential and the time of rest of electrodes at a cut-off circuit on the kinetics of hydrogen recovery were examined. The results obtained for Ni/Pd/C electrodes indicate that the displacement of hydrogen between C and Pd phase takes place during the rest at a cut-off circuit. Electrodes containing carbon layer require longer time for hydrogen electrosorption. On the other hand, the presence of carbon layer in electrodes is advantageous because a considerable longer retention of hydrogen is possible, as compared to Pd/Ni electrode. Hydrogen stored in sandwich-like electrodes can instantly be

  20. Electrode materials for rechargeable batteries

    Science.gov (United States)

    Abouimrane, Ali; Amine, Khalil

    2015-04-14

    Selenium or selenium-containing compounds may be used as electroactive materials in electrodes or electrochemical devices. The selenium or selenium-containing compound is mixed with a carbon material.

  1. Composite substrate for bipolar electrodes

    Science.gov (United States)

    Tekkanat, Bora; Bolstad, James J.

    1992-12-22

    Substrates for electrode systems, particularly those to be used for bipolar electrodes in zinc-bromine batteries, are disclosed. The substrates preferably include carbon-black as a conductive filler in a polymeric matrix, with reinforcing materials such as glass fibers. Warpage of the zinc-bromine electrodes which was experienced in the prior art and which was believed to be caused by physical expansion of the electrodes due to bromine absorption by the carbon-black, is substantially eliminated when new substrate fabrication techniques are employed. In the pesent invention, substrates are prepared using a lamination process known as glass mat reinforced thermoplastics technology or, in an alternate embodiment, the substrate is made using a slurry process.

  2. Amodiaquine polymeric membrane electrode.

    Science.gov (United States)

    Malongo, T Kimbeni; Blankert, B; Kambu, O; Amighi, K; Nsangu, J; Kauffmann, J-M

    2006-04-11

    The construction and electrochemical response characteristics of two types of poly(vinyl chloride) (PVC) membrane sensors for the determination of amodiaquine hydrochloride (ADQ.2HCl) are described. The sensing membrane comprised an ion-pair formed between the cationic drug and sodium tetraphenyl borate (NaTPB) or potassium tetrakis(4-chlorophenyl) borate (KTCPB) in a plasticized PVC matrix. Eight PVC membrane ion-selective electrodes were fabricated and studied. Several plasticizers were studied namely, dioctyl phthalate (DOP), 2-nitrophenyl octyl ether (NPOE), dioctyl phenylphosphonate (DOPP) and bis(2-ethylhexyl)adipate (EHA). The sensors display a fast, stable and near-Nernstian response over a relative wide ADQ concentration range (3.2 x 10(-6) to 2.0 x 10(-2) M), with slopes comprised between 28.5 and 31.4 mV dec(-1) in a pH range comprised between pH 3.7 and 5.5. The assay of amodiaquine hydrochloride in pharmaceutical dosage forms using one of the proposed sensors gave average recoveries of 104.3 and 99.9 with R.S.D. of 0.3 and 0.6% for tablets (Malaritab) and a reconstituted powder containing ADQ.2HCl, respectively. The sensor was also used for dissolution profile studies of two drug formulations. The sensor proved to have a good selectivity for ADQ.2HCl over some inorganic and organic compounds, however, berberine chloride interfered significantly. The results were validated by comparison with a spectrophotometric assay according to the USP pharmacopoeia.

  3. Voltammetry at micro-mesh electrodes

    Directory of Open Access Journals (Sweden)

    Wadhawan Jay D.

    2003-01-01

    Full Text Available The voltammetry at three micro-mesh electrodes is explored. It is found that at sufficiently short experimental durations, the micro-mesh working electrode first behaves as an ensemble of microband electrodes, then follows the behaviour anticipated for an array of diffusion-independent micro-ring electrodes of the same perimeter as individual grid-squares within the mesh. During prolonged electrolysis, the micro-mesh electrode follows that behaviour anticipated theoretically for a cubically-packed partially-blocked electrode. Application of the micro-mesh electrode for the electrochemical determination of carbon dioxide in DMSO electrolyte solutions is further illustrated.

  4. Core–shell Au/Ag nanoparticles embedded in silicate sol–gel ...

    Indian Academy of Sciences (India)

    Administrator

    catalytic reduction and sensing of hydrogen peroxide in comparison to monometal Au and Ag nanoparticles ... metal catalyst. It has been reported in many cases that bimetallic systems display a core–shell struc- ture, where a thin shell of second metal surrounds a ... The homogeneous MTMOS sol–gel matrix was pre- pared.

  5. Diagnostic Genesis Features of Au-Ag Selenide-Telluride Mineralization of Western Java Deposits

    Directory of Open Access Journals (Sweden)

    Euis Tintin Yuningsih

    2016-01-01

    Full Text Available DOI: 10.17014/ijog.3.1.67-76The ore mineralogy of the westernmost part of West Java such as Pongkor, Cibaliung, Cikidang, Cikotok, and Cirotan are characterized by the dominance of silver-arsenic-antimony sulfosalt with silver selenides and rarely tellurides over the argentite, whereas the eastern part of West Java including Arinem and Cineam deposits are dominated by silver-gold tellurides. Mineralogy of Se-type deposits at Pongkor, Cikidang, Cibaliung, Cisungsang, and Cirotan and Te-type deposits at Arinem and Cineam shows their different geochemical characteristics. Mineralogical and geochemical differences can be explained by variation of physico-chemical conditions that existed during gold-silver deposition by applying the phase relation among sulfide, telluride, and selenide mineral association in the deposits. The relative values of ƒSe2(g, ƒTe(g, and ƒS2(g control the actual presence of selenide or telluride minerals within the West Java deposits, which also depend on their concentrations in the hydrothermal fluid. Even though the concentration of selenium in the hydrothermal fluid of Te-type deposits might have been similar or even higher than that in the Se-type, early substitution of selenium in the sulfide minerals prevents its concentration in the hydrothermal fluid to the levels for precipitating selenide minerals. Therefore, early sulfide mineral deposition from reduction fluids will not increase the ƒSe2(g/ƒS2(g ratio to form selenide minerals in Te-type deposits of Arinem and Cineam, other than selenium-bearing sulfide mineral such as Se-bearing galena or Se-bearing pyrargyrite-proustite.

  6. The Precious metals (Au, Ag, Pt, Pd, Rh adsorption on the Silicon – organic sorbents

    Directory of Open Access Journals (Sweden)

    G Burmaa

    2014-09-01

    Full Text Available Sorption activity of two types of Silicon-organic sorbents for the previous metals has been studied. A polymer – poly (3- silsesquioxanilpropylthiocarbamate - 3- silsesquioxanilpropylammonium which was obtained by the hydrolytic poly-condensation reaction and has been determined its physical, chemical characteristics and its sorption activity for the Ag(I, Au(III, Pt(IV, Pd(II, Rh(III. It has been found out that the sorbent shows high static sorption of Gold (III, Mercury (II at acidic condition. The second a net structured silicon-organic copolymer {SiO2*2[O1.5Si(CH23NHC5H4N}n was synthesized by hydrolytic co-poly-condensation reaction. It likely to react as an anionit that adsorbs chloro-complex anion of the Au (III, Pt(IV, Pd(II, Rh(III.DOI: http://dx.doi.org/10.5564/mjc.v12i0.167 Mongolian Journal of Chemistry Vol.12 2011: 29-34

  7. The Precious metals (Au, Ag, Pt, Pd, Rh) adsorption on the Silicon – organic sorbents

    OpenAIRE

    G Burmaa; S Alen; Yu Ganchimeg; I Sukhbaatar

    2014-01-01

    Sorption activity of two types of Silicon-organic sorbents for the previous metals has been studied. A polymer – poly (3- silsesquioxanilpropylthiocarbamate) - 3- silsesquioxanilpropylammonium which was obtained by the hydrolytic poly-condensation reaction and has been determined its physical, chemical characteristics and its sorption activity for the Ag(I), Au(III), Pt(IV), Pd(II), Rh(III). It has been found out that the sorbent shows high static sorption of Gold (III), Mercury (II) at acidi...

  8. Simple and efficient synthesis of [MCI(NHC)] (M = Au, Ag) complexes.

    Science.gov (United States)

    Visbal, Renso; Laguna, Antonio; Gimeno, M Concepción

    2013-06-25

    A facile and efficient synthetic route leading to catalytically relevant N-heterocyclic carbene (NHC) gold complexes is described. The method consists of one pot synthesis starting from readily available imidazolium salts and [AuCl(tht)], in the presence of K2CO3. Using the same protocol NHC silver complexes have been synthesised starting from AgNO3.

  9. Compressed multiwall carbon nanotube composite electrodes provide enhanced electroanalytical performance for determination of serotonin

    International Nuclear Information System (INIS)

    Fagan-Murphy, Aidan; Patel, Bhavik Anil

    2014-01-01

    Serotonin (5-HT) is an important neurochemical that is present in high concentrations within the intestinal tract. Carbon fibre and boron-doped diamond based electrodes have been widely used to date for monitoring 5-HT, however these electrodes are prone to fouling and are difficult to fabricate in certain sizes and geometries. Carbon nanotubes have shown potential as a suitable material for electroanalytical monitoring of 5-HT but can be difficult to manipulate into a suitable form. The fabrication of composite electrodes is an approach that can shape conductive materials into practical electrode geometries suitable for biological environments. This work investigated how compression of multiwall carbon nanotubes (MWCNTs) epoxy composite electrodes can influence their electroanalytical performance. Highly compressed composite electrodes displayed significant improvements in their electrochemical properties along with decreased internal and charge transfer resistance, reproducible behaviour and improved batch to batch variability when compared to non-compressed composite electrodes. Compression of MWCNT epoxy composite electrodes resulted in an increased current response for potassium ferricyanide, ruthenium hexaammine and dopamine, by preferentially removing the epoxy during compression and increasing the electrochemical active surface of the final electrode. For the detection of serotonin, compressed electrodes have a lower limit of detection and improved sensitivity compared to non-compressed electrodes. Fouling studies were carried out in 10 μM serotonin where the MWCNT compressed electrodes were shown to be less prone to fouling than non-compressed electrodes. This work indicates that the compression of MWCNT carbon-epoxy can result in a highly conductive material that can be moulded to various geometries, thus providing scope for electroanalytical measurements and the production of a wide range of analytical devices for a variety of systems

  10. Influência do molibdênio em propriedades do metal de solda na soldagem molhada com eletrodos óxi-rutílicos Influence of molybdenum in metal weld properties in welding wet with oxy-rutillic electrodes

    Directory of Open Access Journals (Sweden)

    Luciana Ferreira Silva

    2013-06-01

    Full Text Available A técnica de soldagem subaquática molhada com eletrodos revestidos apresenta um crescente potencial de aplicação para reparos submarinos em elementos estruturais de unidades flutuantes de produção de petróleo (profundidade até 20 m. Porém, ela apresenta problemas tais como o maior risco de fissuração a frio e de formação acentuada de porosidade. O presente trabalho tem como objetivo melhorar a resistência mecânica do metal de solda de um eletrodo experimental do tipo oxi-rutílico. Foram estudadas as influências de adições de Mo (até 0,4% no metal de solda na microestrutura e em propriedades mecânicas. As soldas foram realizadas em simulador de soldagem subaquática em profundidade equivalente de 10m utilizando um sistema de soldagem por gravidade. As análises das micrografias mostrou que o aumento do teor de Mo no metal de solda diminui significantemente o tamanho médio de grão da região reaquecida de grãos finos. O aumento do teor de Mo no metal de solda resultou, ainda, em aumento do limite de resistência à tração sem perdas de tenacidade e ductilidade até aproximadamente 0,25%Mo.the underwater wet welding with coated electrodes technique is undergoing an important use growth in underwater repairs of oil production floating unit's structural elements (up to 20 m depth. However, it presents problems such as increased risk of cold cracking and sharp porosity formation. This work aims to improve the weld metal's mechanical strength through the addition of molybdenum to experimental oxy-rutilic type electrodes. Both the microstructure and the mechanical properties of weld metals were studied while electrodes would receive additional Mo (up to 0.4%. The welds were done using a gravity welding system placed in an underwater welding simulator with an equivalent depth of 10 m. Analyses of micrographics shown that the increased level of Mo in weld metal (a decreases significantly the average grain size of fine

  11. Development of high temperature reference electrodes for in-pile application: Part I. Feasibility study of the external pressure balanced Ag/AgCl reference electrode (EPBRE) and the cathodically charged Palladium hydrogen electrode

    Energy Technology Data Exchange (ETDEWEB)

    Bosch, R.W.; Van Nieuwenhove, R

    1998-10-01

    The main problems connected with corrosion potential measurements at elevated temperatures and pressures are related to the stability and lifetime of the reference electrode and the correct estimation of the potential related to the Standard Hydrogen Scale (SHE). Under Pressurised Water Reactor (PWR) conditions of 300 degrees Celsius and 150 bar, the choice of materials is also a limiting factor due to the influence of radiation. Investigations on two reference electrodes that can be used under PWR conditions are reported: the cathodically charged palladium hydrogen electrode, and the external pressure balanced silver/silver chloride electrode. Preliminary investigations with the Pd-electrode were focused on the calculation of the required charging time and the influence of dissolved oxygen. High temperature applications are discussed on the basis of results reported in the literature. Investigations with the silver/silver chloride reference electrode mainly dealt with the salt bridge which is necessary to connect the reference electrode with the testing solution. It is shown that the thermal junction potential is independent of the length of the salt bridge. In addition, the high temperature contributes to an increase of the conductivity of the solution, which is beneficial for the salt bridge connection.

  12. Analysis of deep brain stimulation electrode characteristics for neural recording

    Science.gov (United States)

    Kent, Alexander R.; Grill, Warren M.

    2014-08-01

    Objective. Closed-loop deep brain stimulation (DBS) systems have the potential to optimize treatment of movement disorders by enabling automatic adjustment of stimulation parameters based on a feedback signal. Evoked compound action potentials (ECAPs) and local field potentials (LFPs) recorded from the DBS electrode may serve as suitable closed-loop control signals. The objective of this study was to understand better the factors that influence ECAP and LFP recording, including the physical presence of the electrode, the geometrical dimensions of the electrode, and changes in the composition of the peri-electrode space across recording conditions. Approach. Coupled volume conductor-neuron models were used to calculate single-unit activity as well as ECAP responses and LFP activity from a population of model thalamic neurons. Main results. Comparing ECAPs and LFPs measured with and without the presence of the highly conductive recording contacts, we found that the presence of these contacts had a negligible effect on the magnitude of single-unit recordings, ECAPs (7% RMS difference between waveforms), and LFPs (5% change in signal magnitude). Spatial averaging across the contact surface decreased the ECAP magnitude in a phase-dependent manner (74% RMS difference), resulting from a differential effect of the contact on the contribution from nearby or distant elements, and decreased the LFP magnitude (25% change). Reductions in the electrode diameter or recording contact length increased signal energy and increased spatial sensitivity of single neuron recordings. Moreover, smaller diameter electrodes (500 µm) were more selective for recording from local cells over passing axons, with the opposite true for larger diameters (1500 µm). Changes in electrode dimensions had phase-dependent effects on ECAP characteristics, and generally had small effects on the LFP magnitude. ECAP signal energy and LFP magnitude decreased with tighter contact spacing (100 µm), compared to

  13. Numerical study of the effects of carbon felt electrode compression in all-vanadium redox flow batteries

    International Nuclear Information System (INIS)

    Oh, Kyeongmin; Won, Seongyeon; Ju, Hyunchul

    2015-01-01

    Highlights: • The effects of electrode compression on VRFB are examined. • The electronic conductivity is improved when the compression is increased. • The kinetic losses are similar regardless of the electrode compression level. • The vanadium distribution is more uniform within highly compressed electrode. - Abstract: The porous carbon felt electrode is one of the major components of all-vanadium redox flow batteries (VRFBs). These electrodes are necessarily compressed during stack assembly to prevent liquid electrolyte leakage and diminish the interfacial contact resistance among VRFB stack components. The porous structure and properties of carbon felt electrodes have a considerable influence on the electrochemical reactions, transport features, and cell performance. Thus, a numerical study was performed herein to investigate the effects of electrode compression on the charge and discharge behavior of VRFBs. A three-dimensional, transient VRFB model developed in a previous study was employed to simulate VRFBs under two degrees of electrode compression (10% vs. 20%). The effects of electrode compression were precisely evaluated by analysis of the solid/electrolyte potential profiles, transfer current density, and vanadium concentration distributions, as well as the overall charge and discharge performance. The model predictions highlight the beneficial impact of electrode compression; the electronic conductivity of the carbon felt electrode is the main parameter improved by electrode compression, leading to reduction in ohmic loss through the electrodes. In contrast, the kinetics of the redox reactions and transport of vanadium species are not significantly altered by the degree of electrode compression (10% to 20%). This study enhances the understanding of electrode compression effects and demonstrates that the present VRFB model is a valuable tool for determining the optimal design and compression of carbon felt electrodes in VRFBs.

  14. Kinetic and geometric aspects of solid oxide fuel cell electrodes

    DEFF Research Database (Denmark)

    Mogensen, Mogens Bjerg; Skaarup, Steen

    1996-01-01

    the size of the polarisation resistance greatly and may also change the rate limiting step for oxygen reduction as evidenced by the change in dependence on oxygen partial pressure and in the apparent activation energy. O-16/O-19 isotope exchange measurements have shown that oxygen surface exchange takes...... are is much more dependent on the structure than the low frequency arcs. In the case of LSM-YSZ composite it has been demonstrated that both the ratio of LSM to YSZ and the conductivity of the YSZ is of major importance. The length and the nature of the three-phase-boundary between LSM, YSZ and air influence...... place with significant rates on both electrodes and electrolyte types of materials. Results from pointed electrodes indicate that the electrochemical reaction occurs on both the solid electrolyte and the electrode materials but only in a narrow zone (few mu m) along the three-phase-boundary....

  15. Robust high temperature oxygen sensor electrodes

    DEFF Research Database (Denmark)

    Lund, Anders

    Platinum is the most widely used material in high temperature oxygen sensor electrodes. However, platinum is expensive and the platinum electrode may, under certain conditions, suffer from poisoning, which is detrimental for an oxygen sensor. The objective of this thesis is to evaluate electrode...... materials as candidates for robust oxygen sensor electrodes. The present work focuses on characterising the electrochemical properties of a few electrode materials to understand which oxygen electrode processes are limiting for the response time of the sensor electrode. Three types of porous platinum......-Dansensor. The electrochemical properties of the electrodes were characterised by electrochemical impedance spectroscopy (EIS), and the structures were characterised by x-ray diffraction and electron microscopy. At an oxygen partial pressures of 0.2 bar, the response time of the sensor electrode was determined by oxygen...

  16. Control of edge effects of oxidant electrode

    Science.gov (United States)

    Carr, Peter; Chi, Chen H.

    1981-09-08

    Described is an electrode assembly comprising; a. a porous electrode having a first and second exterior face with a cavity formed in the interior between said exterior faces thereby having first and second interior faces positioned opposite the first and second exterior faces; b. a counter electrode positioned facing each of the first and second exterior faces of the porous electrode; c. means for passing an oxidant through said porous electrode; and d. screening means for blocking the interior face of the porous electrode a greater amount than the blocking of the respective exterior face of the porous electrode, thereby maintaining a differential of oxidant electrode surface between the interior face and the exterior face. The electrode assembly is useful in a metal, halogen, halogen hydrate electrical energy storage device.

  17. Composite Electrodes for Electrochemical Supercapacitors

    Directory of Open Access Journals (Sweden)

    Yang QuanMin

    2010-01-01

    Full Text Available Abstract Manganese dioxide nanofibers with length ranged from 0.1 to 1 μm and a diameter of about 4–6 nm were prepared by a chemical precipitation method. Composite electrodes for electrochemical supercapacitors were fabricated by impregnation of the manganese dioxide nanofibers and multiwalled carbon nanotubes (MWCNT into porous Ni plaque current collectors. Obtained composite electrodes, containing 85% of manganese dioxide and 15 mass% of MWCNT, as a conductive additive, with total mass loading of 7–15 mg cm−2, showed a capacitive behavior in 0.5-M Na2SO4 solutions. The decrease in stirring time during precipitation of the nanofibers resulted in reduced agglomeration and higher specific capacitance (SC. The highest SC of 185 F g−1 was obtained at a scan rate of 2 mV s−1 for mass loading of 7 mg cm−2. The SC decreased with increasing scan rate and increasing electrode mass.

  18. RETGEM with polyvinylchloride (PVC) electrodes

    CERN Document Server

    Razin, V I; Reshetin, A I; Filippov, S N

    2009-01-01

    This paper presents a new design of the RETGEM (Resistive Electrode Thick GEM) based on electrodes made of a polyvinylchloride material (PVC). Our device can operate with gains of 10E5 as a conventional TGEM at low counting rates and as RPC in the case of high counting rates without of the transit to the violent sparks. The distinct feature of present RETGEM is the absent of the metal coating and lithographic technology for manufacturing of the protective dielectric rms. The electrodes from PVC permit to do the holes by a simple drilling machine. Detectors on a RETGEM basis could be useful in many fields of an application requiring a more cheap manufacturing and safe operation, for example, in a large neutrino experiments, in TPC, RICH systems.

  19. Nanofiber membrane-electrode-assembly and method of fabricating same

    Science.gov (United States)

    Pintauro, Peter N.; Ballengee, Jason; Brodt, Matthew

    2016-02-02

    In one aspect of the present invention, a fuel cell membrane-electrode-assembly (MEA) has an anode electrode, a cathode electrode, and a membrane disposed between the anode electrode and the cathode electrode. At least one of the anode electrode, the cathode electrode and the membrane is formed of electrospun nanofibers.

  20. Electrode structures of polymer-electrolyte fuel cells (PEFC). An electron microscopy approach to the characterization of the electrode structure of polymer electrolyte fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Scheiba, Frieder

    2009-01-28

    Polymer electrolyte fuel cells (PEFC) have a complex electrode structure, which usually consists of a catalyst, a catalyst support, a polymer electrolyte and pores. The materials used are largely amorphous, have a strong defective structure or have particle diameter of only a few nanometers. In the electrode the materials form highly disordered aggregated structures. Both aspects complicate a systematic structural analysis significantly. However, thorough knowledge of the electrode structure, is needed for systematic advancement of fuel cell technology and to obtain a better understanding of mass and charge carrier transport processes in the electrode. Because of the complex structure of the electrode, an approach based on the examination of electrode thin-sections by electron microscopy was chosen in this work to depicting the electrode structure experimentally. The present work presents these studies of the electrode structure. Some fundamental issues as the influence of the polymer electrolyte concentration and the polarity of the solvent used in the electrode manufacturing process were addressed. During the analysis particular attention was payed to the distribution and structure of the polymer electrolyte. A major problem to the investigations, were the low contrast between the polymer electrolyte, the catalyst support material and the embedding resin. Therefore, dilerent techniques were investigated in terms of their ability to improve the contrast. In this context, a computer-assisted acquisition procedure for energy filtered transmission electron microscopy (EF-TEM) was developed. The acquisition procedure permits a significant extension of the imageable sample. At the same time, it was possible to substantially reduce beam damage of the specimen and to minimize drift of the sample considerably. This allowed unambiguous identification of the polymer electrolyte in the electrode. It could further be shown, that the polymer electrolyte not only coats the

  1. A New Tiapride Selective Electrode and Its Clinical Application

    Directory of Open Access Journals (Sweden)

    Concepción Sánchez-Pedreño

    2007-03-01

    Full Text Available The construction and electrochemical response characteristics of a poly(vinylchloride (PVC membrane selective electrode for the determination of tiapride (TPD are described. The sensing membrane comprised an ion-pair formed between the protonated drug and tetraphenylborate (TPB- in a plasticized PVC matrix. The influence of membrane composition on the electrode response was studied. The electrode showed a fast, stable and Nernstian response over a wide tiapride concentration range (1x10-5-1x10-2 M with a slope of 57.5+/-0.2 mV dec-1 of concentration, a detection limit of 4.3x10-6+/-2.5x10-7 M, a wide working pH range (2-8 and a fast response time (< 5 s. The electrode showed good selectivity towards tiapride with respect to some inorganic and organic compounds. The electrode has been applied to the determination of tiapride in human urine and iontophoresis solution.

  2. Research on interdigitated electrodes piezoelectric fiber composites by FEM

    Science.gov (United States)

    Liu, Yonggang; Shen, Xing; Zhao, Dongbiao; Qiu, Jinhao

    2007-07-01

    Interdigitated electrodes(IDEs) piezoelectric fiber composites is one kind of new smart materials which can be used as actuators in many applications because of its unique properties such as high induced stain and easy integration on curved surface of the base structure. In this paper, basic theories about composite were introduced briefly firstly. Then Electrostatic Field of this special electrode was analyzed. Finally, Finite Element Method is employed to numerically research the influence of thickness and material constants of polymer around electrodes, volume ratio of fibers and dimension of electrodes on the composite's induced strain and stress. The results show that the actuating strain and stress of interdigitated electrodes piezoelectric fiber composites can be improved much by employing polymer having high dielectric constant or decreasing the thickness of the polymer around IDEs. In addition, much higher induced strain and stress can be got by decreasing period of IDEs or increasing width of IDEs and volume ratio of fibers among the composite. At last, the maximum strain (280μɛ) was got from the numeric model of optimized samples, which is very large considering composite is not pure PZT ceramics.

  3. Production method of nickel electrode

    Science.gov (United States)

    Ikeda, H.; Ohira, T.

    1982-01-01

    A nickel electrode having improved charging efficiency, an increased coefficient of discharging utilization, and large capacity is disclosed. Nickel hydroxide or nickel oxide is retained in a porous nickel substrate which is immersed in an aqueous solution of cobalt acetate with a pH 4.0 to 6.8. The electrode thus obtained is then immersed in an alkaline solution or heated to change cobalt acetate into cobalt hydroxide or cobalt oxide whereby the surface of nickel active material is covered with cobalt crystals and alloying of cobalt and nickel is promoted at the same time.

  4. Nanofiber membrane-electrode-assembly and method of fabricating same

    Energy Technology Data Exchange (ETDEWEB)

    Pintauro, Peter N.; Ballengee, Jason; Brodt, Matthew

    2018-01-23

    In one aspect of the present invention, a method of fabricating a fuel cell membrane-electrode-assembly (MEA) having an anode electrode, a cathode electrode, and a membrane disposed between the anode electrode and the cathode electrode, includes fabricating each of the anode electrode, the cathode electrode, and the membrane separately by electrospinning; and placing the membrane between the anode electrode and the cathode electrode, and pressing then together to form the fuel cell MEA.

  5. On the noise performance of pt electrodes.

    Science.gov (United States)

    Liu, Xiao; Demosthenous, Andreas; Donaldson, Nick

    2007-01-01

    We measured the noise and impedance from Pt electrode pairs in a frequency band from 100 Hz to 10 kHz, containing the ENG band (500 Hz 5 kHz). The results show that the Pt electrode noise is the same as the thermal noise from the real part of the electrode impedance, which is a summation of the polarisation resistance and the access resistance. This differs from Ag-AgCl electrodes for which the electrode noise has been reported to be higher than the thermal noise. Our study shows that Pt electrodes are suitable for neural recording.

  6. Modeling of Impedance of Porous Electrodes

    Science.gov (United States)

    Lasia, Andrzej

    Porous electrodes are very important in practical applications of electrocatalysis, where an increase in the real surface area leads to an increase in catalytic activity. Porous electrodes are used in gas evolution (water electrolysis, hydrogen and oxygen evolution, chlorine evolution), electrocatalytic hydrogenation or oxidation of organic compounds, in batteries, fuel cells, etc. Good knowledge of the porous electrode theory permits for the construction of the electrodes with optimal utilization of the active electrode material. The porous electrode model was first developed by several authors for dc conditions (1-6) and later applied to the impedance studies.

  7. Effects of Electrode Material on the Voltage of a Tree-Based Energy Generator.

    Directory of Open Access Journals (Sweden)

    Zhibin Hao

    Full Text Available The voltage between a standing tree and its surrounding soil is regarded as an innovative renewable energy source. This source is expected to provide a new power generation system for the low-power electrical equipment used in forestry. However, the voltage is weak, which has caused great difficulty in application. Consequently, the development of a method to increase the voltage is a key issue that must be addressed in this area of applied research. As the front-end component for energy harvesting, a metal electrode has a material effect on the level and stability of the voltage obtained. This study aimed to preliminarily ascertain the rules and mechanisms that underlie the effects of electrode material on voltage. Electrodes of different materials were used to measure the tree-source voltage, and the data were employed in a comparative analysis. The results indicate that the conductivity of the metal electrode significantly affects the contact resistance of the electrode-soil and electrode-trunk contact surfaces, thereby influencing the voltage level. The metal reactivity of the electrode has no significant effect on the voltage. However, passivation of the electrode materials markedly reduces the voltage. Suitable electrode materials are demonstrated and recommended.

  8. Engineering and Optimization of Silicon-Iron-Manganese Nanoalloy Electrode for Enhanced Lithium-Ion Battery

    Science.gov (United States)

    Alaboina, Pankaj K.; Cho, Jong-Soo; Cho, Sung-Jin

    2017-10-01

    The electrochemical performance of a battery is considered to be primarily dependent on the electrode material. However, engineering and optimization of electrodes also play a crucial role, and the same electrode material can be designed to offer significantly improved batteries. In this work, Si-Fe-Mn nanomaterial alloy (Si/alloy) and graphite composite electrodes were densified at different calendering conditions of 3, 5, and 8 tons, and its influence on electrode porosity, electrolyte wettability, and long-term cycling was investigated. The active material loading was maintained very high ( 2 mg cm-2) to implement electrode engineering close to commercial loading scales. The densification was optimized to balance between the electrode thickness and wettability to enable the best electrochemical properties of the Si/alloy anodes. In this case, engineering and optimizing the Si/alloy composite electrodes to 3 ton calendering (electrode densification from 0.39 to 0.48 g cm-3) showed enhanced cycling stability with a high capacity retention of 100% over 100 cycles. [Figure not available: see fulltext.

  9. Surface-treated carbon electrodes with modified potential of zero charge for capacitive deionization.

    Science.gov (United States)

    Wu, Tingting; Wang, Gang; Zhan, Fei; Dong, Qiang; Ren, Qidi; Wang, Jianren; Qiu, Jieshan

    2016-04-15

    The potential of zero charge (Epzc) of electrodes can greatly influence the salt removal capacity, charge efficiency and cyclic stability of capacitive deionization (CDI). Thus optimizing the Epzc of CDI electrodes is of great importance. A simple strategy to negatively shift the Epzc of CDI electrodes by modifying commercial activated carbon with quaternized poly (4-vinylpyridine) (AC-QPVP) is reported in this work. The Epzc of the prepared AC-QPVP composite electrode is as negative as -0.745 V vs. Ag/AgCl. Benefiting from the optimized Epzc of electrodes, the asymmetric CDI cell which consists of the AC-QPVP electrode and a nitric acid treated activated carbon (AC-HNO3) electrode exhibits excellent CDI performance. For inverted CDI, the working potential window of the asymmetric CDI cell can reach 1.4 V, and its salt removal capacity can be as high as 9.6 mg/g. For extended voltage CDI, the salt removal capacity of the asymmetric CDI cell at 1.2/-1.2 V is 20.6 mg/g, which is comparable to that of membrane CDI using pristine activated carbon as the electrodes (19.5 mg/g). The present work provides a simple method to prepare highly positively charged CDI electrodes and may pave the way for the development of high-performance CDI cells. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. The detailed characteristics of positive corona current pulses in the line-to-plane electrodes

    Science.gov (United States)

    Xuebao, LI; Dayong, LI; Qian, ZHANG; Yinfei, LI; Xiang, CUI; Tiebing, LU

    2018-05-01

    The corona current pulses generated by corona discharge are the sources of the radio interference from transmission lines and the detailed characteristics of the corona current pulses from conductor should be investigated in order to reveal their generation mechanism. In this paper, the line-to-plane electrodes are designed to measure and analyze the characteristics of corona current pulses from positive corona discharges. The influences of inter-electrode gap and line diameters on the detail characteristics of corona current pulses, such as pulse amplitude, rise time, duration time and repetition frequency, are carefully analyzed. The obtained results show that the pulse amplitude and the repetition frequency increase with the diameter of line electrode when the electric fields on the surface of line electrodes are same. With the increase of inter-electrode gap, the pulse amplitude and the repetition frequency first decrease and then turn to be stable, while the rise time first increases and finally turns to be stable. The distributions of electric field and space charges under the line electrodes are calculated, and the influences of inter-electrode gap and line electrode diameter on the experimental results are qualitatively explained.

  11. Analysis of SOFCs Using Reference Electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Finklea, H.; Chen, X.; Gerdes, K.; Pakalapati, S.; Celik, I.

    2013-01-01

    Reference electrodes are frequently applied to isolate the performance of one electrode in a solid oxide fuel cell. However, reference electrode simulations raise doubt to veracity of data collected using reference electrodes. The simulations predict that the reported performance for the one electrode will frequently contain performance of both electrodes. Nonetheless, recent reports persistently treat data so collected as ideally isolated. This work confirms the predictions of the reference electrode simulations on two SOFC designs, and to provides a method of validating the data measured in the 3-electrode configuration. Validation is based on the assumption that a change in gas composition to one electrode does not affect the impedance of the other electrode at open circuit voltage. This assumption is supported by a full physics simulation of the SOFC. Three configurations of reference electrode and cell design are experimentally examined using various gas flows and two temperatures. Impedance data are subjected to deconvolution analysis and equivalent circuit fitting and approximate polarization resistances of the cathode and anode are determined. The results demonstrate that the utility of reference electrodes is limited and often wholly inappropriate. Reported impedances and single electrode polarization values must be scrutinized on this basis.

  12. Luminescence studies of semiconductor electrodes

    NARCIS (Netherlands)

    Kelly, J.J.; Kooij, Ernst S.; Meulenkamp, E.A.

    1999-01-01

    In this paper we review our recent results of in-situ luminescence studies of semiconductor electrodes. Three classes of materials are considered: single crystal compound semiconductors, porous silicon and semiconducting oxides doped with luminescent ions. We show how photoluminescence (PL) and

  13. Noise properties of textile, capacitive EEG electrodes

    Directory of Open Access Journals (Sweden)

    Asl Sara Nazari

    2015-09-01

    Full Text Available The rigid surface of the conventional PCB-based capacitive electrode produces an undefined distance between the skin and the electrode surface. Therefore, the capacitance introduced by them is uncertain and can vary from electrode to electrode due to their different positions on the scalp. However, textile electrodes which use conductive fabric as electrode surfaces, are bendable over the scalp. Therefore, it provides a certain value of the capacitance which is predictable and calculable accurately if the effective distance to the scalp surface can be determined. In this paper noise characteristics of textile electrodes with different fabric sizes as electrode’s surface and capacity calculations related to each size are presented to determine the effective distances for each electrode size.

  14. Integral skin electrode for electrocardiography is expendable

    Science.gov (United States)

    1966-01-01

    Inexpensive, expendable skin electrode for use in electrocardiography combines an electrical contact, conductive paste, and a skin-attachment adhesive. Application of the electrode requires only degreasing of the skin area.

  15. Recovery of fluoride ion selective electrode

    International Nuclear Information System (INIS)

    Monteiro, R.P.G.

    1988-01-01

    A recovery procedure of fluoride ion selective electrode based upon the body radiography of inactive electrode and introduction of suitable internal regeneration solution, is developed. The recovered electrode was tested in standard solutions of fluoride ions (10 sup5) to 10 -1M showing as good performance as the new one. The fluor determination by potentiometric measurements with selective electrode is used in nuclear fuel cycle for quality control of thorium and uranium mixed oxide pellets and pellets of uranium dioxides. (author) [pt

  16. Alkali metal ion battery with bimetallic electrode

    Science.gov (United States)

    Boysen, Dane A; Bradwell, David J; Jiang, Kai; Kim, Hojong; Ortiz, Luis A; Sadoway, Donald R; Tomaszowska, Alina A; Wei, Weifeng; Wang, Kangli

    2015-04-07

    Electrochemical cells having molten electrodes having an alkali metal provide receipt and delivery of power by transporting atoms of the alkali metal between electrode environments of disparate chemical potentials through an electrochemical pathway comprising a salt of the alkali metal. The chemical potential of the alkali metal is decreased when combined with one or more non-alkali metals, thus producing a voltage between an electrode comprising the molten the alkali metal and the electrode comprising the combined alkali/non-alkali metals.

  17. Minimizing electrode contamination in an electrochemical cell

    Science.gov (United States)

    Kim, Yu Seung; Zelenay, Piotr; Johnston, Christina

    2014-12-09

    An electrochemical cell assembly that is expected to prevent or at least minimize electrode contamination includes one or more getters that trap a component or components leached from a first electrode and prevents or at least minimizes them from contaminating a second electrode.

  18. Fluctuations at Electrode-YSZ Interfaces

    DEFF Research Database (Denmark)

    Jacobsen, Torben; Hansen, Karin Vels; Skou, Eivind

    in performance [\\ref{McEvoy}, \\ref{Adler}]. This sensitivity to the pre-history is probably one of the explanations for the discrepancies between results reported for single electrode studies. The mechanism behind the activation is still an unresolved problem. In the case of point electrodes, i.e. electrodes...

  19. Measurement of noise and impedance of dry and wet textile electrodes, and textile electrodes with hydrogel.

    Science.gov (United States)

    Puurtinen, Merja M; Komulainen, Satu M; Kauppinen, Pasi K; Malmivuo, Jaakko A V; Hyttinen, Jari A K

    2006-01-01

    Textile sensors, when embedded into clothing, can provide new ways of monitoring physiological signals, and improve the usability and comfort of such monitoring systems in the areas of medical, occupational health and sports. However, good electrical and mechanical contact between the electrode and the skin is very important, as it often determines the quality of the signal. This paper introduces a study where the properties of dry textile electrodes, textile electrodes moistened with water, and textile electrodes covered with hydrogel were studied with five different electrode sizes. The aim was to study how the electrode size and preparation of the electrode (dry electrode/wet electrode/electrode covered with hydrogel membrane) affect the measurement noise, and the skin-electrode impedance. The measurement noise and skin-electrode impedance were determined from surface biopotential measurements. These preliminary results indicate that noise level increases as the electrode size decreases. The noise level is high in dry textile electrodes, as expected. Yet, the noise level of wet textile electrodes is quite low and similar to that of textile electrodes covered with hydrogel. Hydrogel does not seem to improve noise properties, however it may have effects on movement artifacts. Thus, it is feasible to use textile embedded sensors in physiological monitoring applications when moistening or hydrogel is applied.

  20. Studying the Performance of Conductive Polymer Films as Textile Electrodes for Electrical Bioimpedance Measurements

    Science.gov (United States)

    Cunico, F. J.; Marquez, J. C.; Hilke, H.; Skrifvars, M.; Seoane, F.

    2013-04-01

    With the goal of finding novel biocompatible materials suitable to replace silver in the manufacturing of textile electrodes for medical applications of electrical bioimpedance spectroscopy, three different polymeric materials have been investigated. Films have been prepared from different polymeric materials and custom bracelets have been confectioned with them. Tetrapolar total right side electrical bioimpedance spectroscopy (EBIS) measurements have been performed with polymer and with standard gel electrodes. The performance of the polymer films was compared against the performance of the gel electrodes. The results indicated that only the polypropylene 1380 could produce EBIS measurements but remarkably tainted with high frequency artefacts. The influence of the electrode mismatch, stray capacitances and large electrode polarization impedance are unclear and they need to be clarified with further studies. If sensorized garments could be made with such biocompatible polymeric materials the burden of considering textrodes class III devices could be avoided.

  1. Studying the Performance of Conductive Polymer Films as Textile Electrodes for Electrical Bioimpedance Measurements

    International Nuclear Information System (INIS)

    Cunico, F J; Marquez, J C; Hilke, H; Skrifvars, M; Seoane, F

    2013-01-01

    With the goal of finding novel biocompatible materials suitable to replace silver in the manufacturing of textile electrodes for medical applications of electrical bioimpedance spectroscopy, three different polymeric materials have been investigated. Films have been prepared from different polymeric materials and custom bracelets have been confectioned with them. Tetrapolar total right side electrical bioimpedance spectroscopy (EBIS) measurements have been performed with polymer and with standard gel electrodes. The performance of the polymer films was compared against the performance of the gel electrodes. The results indicated that only the polypropylene 1380 could produce EBIS measurements but remarkably tainted with high frequency artefacts. The influence of the electrode mismatch, stray capacitances and large electrode polarization impedance are unclear and they need to be clarified with further studies. If sensorized garments could be made with such biocompatible polymeric materials the burden of considering textrodes class III devices could be avoided.

  2. Mathematical modeling of chemotaxis and glial scarring around implanted electrodes

    Science.gov (United States)

    Silchenko, Alexander N.; Tass, Peter A.

    2015-02-01

    It is well known that the implantation of electrodes for deep brain stimulation or microelectrode probes for the recording of neuronal activity is always accompanied by the response of the brain’s immune system leading to the formation of a glial scar around the implantation sites. The implantation of electrodes causes massive release of adenosine-5‧-triphosphate (ATP) and different cytokines into the extracellular space and activates the microglia. The released ATP and the products of its hydrolysis, such as ADP and adenosine, become the main elements mediating chemotactic sensitivity and motility of microglial cells via subsequent activation of P2Y2,12 as well as A3A/A2A adenosine receptors. The size and density of an insulating sheath around the electrode, formed by microglial cells, are important criteria for the optimization of the signal-to-noise ratio during microelectrode recordings or parameters of electrical current delivered to the brain tissue. Here, we study a purinergic signaling pathway underlying the chemotactic motion of microglia towards implanted electrodes as well as the possible impact of an anti-inflammatory coating consisting of the interleukin-1 receptor antagonist. We present a model describing the formation of a stable aggregate around the electrode due to the joint chemo-attractive action of ATP and ADP and the mixed influence of extracellular adenosine. The bioactive coating is modeled as a source of chemo-repellent located near the electrode surface. The obtained analytical and numerical results allowed us to reveal the dependences of size and spatial location of the insulating sheath on the amount of released ATP and estimate the impact of immune suppressive coating on the scarring process.

  3. Long life lithium batteries with stabilized electrodes

    Science.gov (United States)

    Amine, Khalil [Downers Grove, IL; Liu, Jun [Naperville, IL; Vissers, Donald R [Naperville, IL; Lu, Wenquan [Darien, IL

    2009-03-24

    The present invention relates to non-aqueous electrolytes having electrode stabilizing additives, stabilized electrodes, and electrochemical devices containing the same. Thus the present invention provides electrolytes containing an alkali metal salt, a polar aprotic solvent, and an electrode stabilizing additive. In some embodiments the additives include a substituted or unsubstituted cyclic or spirocyclic hydrocarbon containing at least one oxygen atom and at least one alkenyl or alkynyl group. When used in electrochemical devices with, e.g., lithium manganese oxide spinel electrodes or olivine or carbon-coated olivine electrodes, the new electrolytes provide batteries with improved calendar and cycle life.

  4. A novel method of fabricating carbon nanotubes-polydimethylsiloxane composite electrodes for electrocardiography.

    Science.gov (United States)

    Liu, Benyan; Chen, Yingmin; Luo, Zhangyuan; Zhang, Wenzan; Tu, Quan; Jin, Xun

    2015-01-01

    Polymer-based flexible electrodes are receiving much attention in medical applications due to their good wearing comfort. The current fabrication methods of such electrodes are not widely applied. In this study, polydimethylsiloxane (PDMS) and conductive additives of carbon nanotubes (CNTs) were employed to fabricate composite electrodes for electrocardiography (ECG). A three-step dispersion process consisting of ultrasonication, stirring, and in situ polymerization was developed to yield homogenous CNTs-PDMS mixtures. The CNTs-PDMS mixtures were used to fabricate CNTs-PDMS composite electrodes by replica technology. The influence of ultrasonication time and CNT concentration on polymer electrode performance was evaluated by impedance and ECG measurements. The signal amplitude of the electrodes prepared using an ultrasonication time of 12 h and CNT content of 5 wt% was comparable to that of commercial Ag/AgCl electrodes. The polymer electrodes were easily fabricated by conventional manufacturing techniques, indicating a potential advantage of reduced cost for mass production.

  5. Controlling interfered area in interferential current stimulation by electrode-area patterning.

    Science.gov (United States)

    Bounyong, S; Adachi, S; Yoshimoto, T; Ota, T; Ozawa, J

    2016-08-01

    Interferential current therapy is a noninvasive therapy using simultaneously two or more medium-frequency currents passing through tissue. By controlling the interfered area of the current flows, selective stimulation is possible in target muscles, including deep muscles. However, controlling the interfered area or the intensity of the current precisely is still lacking. Using simulations based on a biological model of the thigh as well as electrical muscle stimulation (EMS) experiments, we investigated the influence of electrode area ratio in changing the interfered area of the currents. Simulation and experiments were conducted under the same conditions, whereby current signals were applied through electrodes placed on the quadriceps and hamstring with an electrode area ratio of either 1:1 or 3:1. A comparison of the simulation results showed that the interferential current density decreased near the larger area electrode but increased near the smaller area electrode. In addition, the EMS experiment also showed that the quadriceps were stimulated using electrodes in a 1:1 area ratio, and the hamstrings were stimulated using electrodes in a 3:1 area ratio. These results demonstrated the possibility of controlling the area application of interferential current through electrode area patterning.

  6. Piercing by composite electrode tool

    International Nuclear Information System (INIS)

    Abdukarimov, Eh.T.; Krakov, B.G.; Saidinov, S.Ya.

    1990-01-01

    The construction of the electrode consisting of a dielectric shell, where a working liquid enters, and a metal rod is designed for precision super-deep piercing by the electroerosion treatment method. Technological parameters of piercing with small diameter (0.5-1.9 mm) for 12Kh18N10T steel, copper and tungsten are presented. A possibility to use a new tool for treating components of any form and sizes is marked

  7. Potentiometric titration with polarized electrodes

    International Nuclear Information System (INIS)

    Chikryzova, E.G.

    1977-01-01

    Based on the analysis of the works carried out during 1911-75 consideration is given to the present state of the method of potentiometric titration with polarized electrodes. The material is generalized in the tabular form indicating the elments of interest, titration conditions and the objects to be analyzed. The list and classification of the potentiometric titration methods intended for determining organic and inorganic substances are presented

  8. Electrode Surface Composition of Dual-Intercalation, All-Graphite Batteries

    Directory of Open Access Journals (Sweden)

    Boris Dyatkin

    2017-02-01

    Full Text Available Dual-intercalation batteries implement graphite electrodes as both cathodes and anodes and offer high specific energy, inexpensive and environmentally sustainable materials, and high operating voltages. Our research investigated the influence of surface composition on capacities and cycling efficiencies of chemically functionalized all-graphite battery electrodes. We subjected coreshell spherical particles and synthetic graphite flakes to high-temperature air oxidation, and hydrogenation to introduce, respectively, –OH, and –H surface functional groups. We identified noticeable influences of electrode surface chemistry on first-cycle efficiencies and charge storage densities of anion and cation intercalation into graphite electrodes. We matched oxidized cathodes and hydrogenated anodes in dual-ion batteries and improved their overall performance. Our approach provides novel fundamental insight into the anion intercalation process and suggests inexpensive and environmentally sustainable methods to improve performance of these grid-scale energy storage systems

  9. Theoretical Simulation on the Assembly of Carbon Nanotubes Between Electrodes by AC Dielectrophoresis

    Directory of Open Access Journals (Sweden)

    Yang Liu

    2008-01-01

    Full Text Available Abstract The assembly of single-walled carbon nanotubes (SWCNTs using the AC dielectrophoresis technique is studied theoretically. It is found that the comb electrode bears better position control of SWCNTs compared to the parallel electrode. In the assembly, when some SWCNTs bridge the electrode first, they can greatly alter the local electrical field so as to “screen off” later coming SWCNTs, which contributes to the formation of dispersed SWCNT array. The screening distance scales with the gap width of electrodes and the length of SWCNTs, which provides a way to estimate the assembled density of SWCNTs. The influence of thermal noise on SWCNTs alignment is also analyzed in the simulation. It is shown that the status of the array distribution for SWCNTs is decided by the competition between the thermal noise and the AC electric-field strength. This influence of the thermal noise can be suppressed by using higher AC voltage to assemble the SWCNTs.

  10. Thin metal layer as transparent electrode in n-i-p amorphous silicon solar cells

    Directory of Open Access Journals (Sweden)

    Theuring Martin

    2014-07-01

    Full Text Available In this paper, transparent electrodes, based on a thin silver film and a capping layer, are investigated. Low deposition temperature, flexibility and low material costs are the advantages of this type of electrode. Their applicability in structured n-i-p amorphous silicon solar cells is demonstrated in simulation and experiment. The influence of the individual layer thicknesses on the solar cell performance is discussed and approaches for further improvements are given. For the silver film/capping layer electrode, a higher solar cell efficiency could be achieved compared to a reference ZnO:Al front contact.

  11. Activation and discharge kinetics of metal hydride electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Johnsen, Stein Egil

    2003-07-01

    Potential step chronoamperometry and Electrochemical Impedance Spectroscopy (eis) measurements were performed on single metal hydride particles. For the {alpha}-phase, the bulk diffusion coefficient and the absorption/adsorption rate parameters were determined. Materials produced by atomisation, melt spinning and conventional casting were investigated. The melt spun and conventional cast materials were identical and the atomised material similar in composition. The particles from the cast and the melt spun material were shaped like parallelepipeds. A corresponding equation, for this geometry, for diffusion coupled to an absorption/adsorption reaction was developed. It was found that materials produced by melt spinning exhibited lower bulk diffusion (1.7E-14 m2/s) and absorption/adsorption reaction rate (1.0E-8 m/s), compared to materials produced by conventionally casting (1.1E-13 m2/s and 5.5E-8 m/s respectively). In addition, the influence of particle active surface and relative diffusion length were discussed. It was concluded that there are uncertainties connected to these properties, which may explain the large distribution in the kinetic parameters measured on metal hydride particles. Activation of metal hydride forming materials has been studied and an activation procedure, for porous electrodes, was investigated. Cathodic polarisation of the electrode during a hot alkaline surface treatment gave the maximum discharge capacity on the first discharge of the electrode. The studied materials were produced by gas atomisation and the spherical shape was retained during the activation. Both an AB{sub 5} and an AB{sub 2} alloy was successfully activated and discharge rate properties determined. The AB{sub 2} material showed a higher maximum discharge capacity, but poor rate properties, compared to the AB{sub 5} material. Reduction of surface oxides, and at the same time protection against corrosion of active metallic nickel, can explain the satisfying results of

  12. All-solid-state reference electrodes based on conducting polymers.

    Science.gov (United States)

    Kisiel, Anna; Marcisz, Honorata; Michalska, Agata; Maksymiuk, Krzysztof

    2005-12-01

    A novel construction of solution free (pseudo)reference electrodes, compatible with all-solid-state potentiometric indicator electrodes, has been proposed. These electrodes use conducting polymers (CP): polypyrrole (PPy) or poly(3,4-ethylenedioxythiophene) (PEDOT). Two different arrangements have been tested: solely based on CP and those where the CP phase is covered with a poly(vinyl chloride) based outer membrane of tailored composition. The former arrangement was designed to suppress or compensate cation- and anion-exchange, using mobile perchlorate ions and poly(4-styrenesulfonate) or dodecylbenzenesulfonate anions as immobilized dopants. The following systems were used: (i) polypyrrole layers doped simultaneously by two kinds of anions, both mobile and immobilized in the polymer layer; (ii) bilayers of polypyrrole with anion exchanging inner layer and cation-exchanging outer layer; (iii) polypyrrole doped by surfactant dodecylbenzenesulfonate ions, which inhibit ion exchange on the polymer/solution interface. For the above systems, recorded potentials have been found to be practically independent of electrolyte concentration. The best results, profound stability of potentials, have been obtained for poly(3,4-ethylenedioxythiophene) or polypyrrole doped by poly(4-styrenesulfonate) anions covered by a poly(vinyl chloride) based membrane, containing both anion- and cation-exchangers as well as solid potassium chloride and silver chloride with metallic silver. Differently to the cases (i)-(iii) these electrodes are much less sensitive to the influence of redox and pH interferences. This arrangement has been also characterized using electrochemical impedance spectroscopy and chronopotentiometry.

  13. Characterization and electrocatalytic application of silver modified polypyrrole electrodes

    Directory of Open Access Journals (Sweden)

    A. DEKANSKI

    2005-02-01

    Full Text Available Silver modified polypyrrole electrodeswere preparedwith the aim of testing them for the electrooxidation of formaldehyde in alkaline solution. The modification of polypyrrole by immersion in aqueous AgNO3 solution was studied by cyclic voltammetry and vacuum techniques (AES and XPS. The influence of time of immersion and the thickness of the polypyrrole film, prepared by electrochemical polymerization, on the modification of the polymer were examined. The results acquired from both electrochemical and spectroscopic examinations show that immersion of a polypyrrole electrode in a AgNO3 solution results in its modificationwith silver, which is deposited in the elemental state on the surface. The quantity of silver deposited depends not only on the immersion time but also on the thickness of the polymer film. A modified PPy/Ag electrode exhibits catalytic activity for the electrooxidation of CH2O in NaOH. In spite of the low quantity of silver, the activity of the electrode for this reaction is comparable to that of a polycrystalline silver electrode.

  14. Development of a system to measure local measurement conditions around textile electrodes.

    Science.gov (United States)

    Kim, Saim; Oliveira, Joana; Roethlingshoefer, Lisa; Leonhard, Steffen

    2010-01-01

    The three main influence factors on the interface between textile electrode an skin are: temperature, contact pressure and relative humidity. This paper presents first results of a prototype, which measures these local measurement conditions around textile electrodes. The wearable prototype is a data acquisition system based on a microcontroller with a flexible sensor sleeve. Validation measurements included variation of ambient temperature, contact pressures and sleeve material. Results show a good correlation with data found in literature.

  15. Impulse space charge and dielectric characteristics of an Al2O3 nanoparticle suspension in propylene carbonate using various electrode materials

    Directory of Open Access Journals (Sweden)

    Qing Yang

    2016-09-01

    Full Text Available We tested the impulse breakdown voltage of Al2O3 “nano-modified” propylene carbonate between different electrode materials. At any given concentration, the breakdown voltage was highest with stainless steel electrodes, followed by copper, and then aluminum. The space charge and electric field distributions were measured too. Results show that less space charge was injected by the electrodes, and the electric field was less distorted, than in pure propylene carbonate. However, the hoped-for reduction of the influence of the electrodes did not take place. Substantial differences in the space charge density and electric field distortion remained between the different electrode materials.

  16. Curved Microneedle Array-Based sEMG Electrode for Robust Long-Term Measurements and High Selectivity

    Directory of Open Access Journals (Sweden)

    Minjae Kim

    2015-07-01

    Full Text Available Surface electromyography is widely used in many fields to infer human intention. However, conventional electrodes are not appropriate for long-term measurements and are easily influenced by the environment, so the range of applications of sEMG is limited. In this paper, we propose a flexible band-integrated, curved microneedle array electrode for robust long-term measurements, high selectivity, and easy applicability. Signal quality, in terms of long-term usability and sensitivity to perspiration, was investigated. Its motion-discriminating performance was also evaluated. The results show that the proposed electrode is robust to perspiration and can maintain a high-quality measuring ability for over 8 h. The proposed electrode also has high selectivity for motion compared with a commercial wet electrode and dry electrode.

  17. A simultaneous comparison of acupuncture needle and insulated needle sphenoidal electrodes for detection of anterior temporal spikes.

    Science.gov (United States)

    Chu, N S

    1992-01-01

    Uninsulated acupuncture needles have been used as sphenoidal electrodes, but the issue of insulation has not been adequately addressed. In this report, acupuncture needles and insulated needle sphenoidal electrodes were simultaneously used to compare the rate of spike detection, spike amplitude and distribution of maximal spikes from eight spike foci in seven patients with temporal lobe epilepsy. When compared to the insulated needle electrode, the acupuncture needle electrode was equally effective in spike detection, but spike amplitudes tended to be smaller and maximal spikes were less frequently encountered. Thus, insulation has an influence on the spikes recorded by the acupuncture needle sphenoidal electrode. However, the overall effect appears to be not sufficiently different from the insulated needle electrode for the purpose of detecting anterior temporal spikes in outpatient EEG recordings for the diagnosis of temporal lobe epilepsy.

  18. A comparative study on electrochemical performances of the electrodes with different nanocarbon conductive additives for lithium ion batteries

    International Nuclear Information System (INIS)

    Chen, Taiqiang; Pan, Likun; Liu, Xinjuan; Sun, Zhuo

    2013-01-01

    Three nanocarbon materials (0 D acetylene black (AB), 1 D carbon nanotubes (CNTs) and 2 D reduced graphene oxide (RGO)) were used as conductive additives (CAs) in the mesocarbon microbead anodes for lithium ion batteries. The electrochemical performances of the electrodes were investigated. The results show that the CAs have a significant impact on the electrode performance because they can influence the electron conduction and lithium ion transportation within the electrode. The electrode with RGO achieves a maximum capacity of 387 mAh g −1 after 50 cycles at a current density of 50 mA g −1 , much higher than those of the electrodes with AB (334 mAh g −1 ) and CNTs (319 mAh g −1 ). The improvement should be mainly ascribed to the “plane-to-point” conducting network formed in the electrode with 2 D RGO which can favor the electron conduction and enhance the lithium ion transportation. - Highlights: • Three carbon materials were used as additives in the electrodes of Li ion battery. • The electrochemical performances of the electrodes were comparatively investigated. • The carbon additives have a significant impact on the electrode performance. • RGO additive acts as a bridge to form a “plane-to-point” conducting network. • The electrode with RGO exhibits better performance than those with other additives

  19. Schiff Base modified on CPE electrode and PCB gold electrode for selective determination of silver ion

    Science.gov (United States)

    Leepheng, Piyawan; Suramitr, Songwut; Phromyothin, Darinee

    2017-09-01

    The schiff base was synthesized by 2,5-thiophenedicarboxaldehyde and 1,2,4-thiadiazole-3,5-diamine with condensation method. There was modified on carbon paste electrode (CPE) and Printed circuit board (PCB) gold electrode for determination silver ion. The schiff base modified electrodes was characterized by atomic force microscopy (AFM) and scanning electron microscopy (SEM), respectively. The electrochemical study was reported by cyclic voltammetry method and impedance spectroscopy using modified electrode as working electrode, platinum wire and Ag/AgCl as counter electrode and reference electrode, respectively. The modified electrodes have suitable detection for Ag+. The determination of silver ions using the modified electrodes depended linearly on Ag+ concentration in the range 1×10-10 M to 1×10-7 M, with cyclic voltammetry sensitivity were 2.51×108 μAM-1 and 1.88×108 μAM-1 for PCB gold electrode and CPE electrode, respectively, limits of detection were 5.33×10-9 M and 1.99×10-8 M for PCB gold electrode and CPE electrode, respectively. The modified electrodes have high accuracy, inexpensive and can applied to detection Ag+ in real samples.

  20. HVDC Ground Electrodes and Tectonic Setting

    Science.gov (United States)

    Freire, P. F.; Pereira, S. Y.

    2017-12-01

    Ground electrodes in HVDC transmission are huge grounding systems for the DC part of the converter substation, about 1 km wide, sized to inject in the ground DC currents up to 3.5 kA. This work presents an analysis of how the tectonic setting at converter substation location is determinant for the search of the best electrode location (Site Selection) and on its design and performance. It will briefly present the author experience on HVDC electrode design, summarized as follows: Itaipu - Foz do Iguaçu electrodes (transmitter side) located in the middle of Paraná Sedimentary Basin, and Ibiúna electrodes (receiving side) on the border of the basin, 6 km from the geological strike, where the crystalline basement outcrops in São Paulo state; Madeira River - North electrodes (transmitting side) located on the Northwest border of South Amazon Craton, where the crystalline basement is below a shallow sediments layer, and South electrodes (receiving side) located within Paraná Sedimentary Basin; Chile - electrodes located on the Andean forearc, where the Nazca Plate plunges under the South American Plate; Kenya - Ethiopia - electrodes located in the African Rift; Belo Monte - North electrodes (transmitter side) located within the Amazonian Sedimentary Basin, about 35 km of its South border, and South electrodes (receiving side) within Paraná Sedimentary Basin (bipole 1) and on crystalline metamorphic terrain "Brasília Belt" (bipole 2). This diversity of geological conditions results on ground electrodes of different topologies and dimensions, with quite different electrical and thermal performances. A brief study of the geology of the converter stations regions, the so-called Desktop Study, allows for the preview of several important parameters for the site selection and design of the electrodes, such as localization, type, size and estimate of the interference area, which are important predictors of the investment to be made and indications of the design to be

  1. Cobalt Phthalocyanine Modified Electrodes Utilised in Electroanalysis: Nano-Structured Modified Electrodes vs. Bulk Modified Screen-Printed Electrodes

    Science.gov (United States)

    Foster, Christopher W.; Pillay, Jeseelan; Metters, Jonathan P.; Banks, Craig E.

    2014-01-01

    Cobalt phthalocyanine (CoPC) compounds have been reported to provide electrocatalytic performances towards a substantial number of analytes. In these configurations, electrodes are typically constructed via drop casting the CoPC onto a supporting electrode substrate, while in other cases the CoPC complex is incorporated within the ink of a screen-printed sensor, providing a one-shot economical and disposable electrode configuration. In this paper we critically compare CoPC modified electrodes prepared by drop casting CoPC nanoparticles (nano-CoPC) onto a range of carbon based electrode substrates with that of CoPC bulk modified screen-printed electrodes in the sensing of the model analytes l-ascorbic acid, oxygen and hydrazine. It is found that no “electrocatalysis” is observed towards l-ascorbic acid using either of these CoPC modified electrode configurations and that the bare underlying carbon electrode is the origin of the obtained voltammetric signal, which gives rise to useful electroanalytical signatures, providing new insights into literature reports where “electrocatalysis” has been reported with no clear control experiments undertaken. On the other hand true electrocatalysis is observed towards hydrazine, where no such voltammetric features are witnessed on the bare underlying electrode substrate. PMID:25414969

  2. Cobalt phthalocyanine modified electrodes utilised in electroanalysis: nano-structured modified electrodes vs. bulk modified screen-printed electrodes.

    Science.gov (United States)

    Foster, Christopher W; Pillay, Jeseelan; Metters, Jonathan P; Banks, Craig E

    2014-11-19

    Cobalt phthalocyanine (CoPC) compounds have been reported to provide electrocatalytic performances towards a substantial number of analytes. In these configurations, electrodes are typically constructed via drop casting the CoPC onto a supporting electrode substrate, while in other cases the CoPC complex is incorporated within the ink of a screen-printed sensor, providing a one-shot economical and disposable electrode configuration. In this paper we critically compare CoPC modified electrodes prepared by drop casting CoPC nanoparticles (nano-CoPC) onto a range of carbon based electrode substrates with that of CoPC bulk modified screen-printed electrodes in the sensing of the model analytes L-ascorbic acid, oxygen and hydrazine. It is found that no "electrocatalysis" is observed towards L-ascorbic acid using either of these CoPC modified electrode configurations and that the bare underlying carbon electrode is the origin of the obtained voltammetric signal, which gives rise to useful electroanalytical signatures, providing new insights into literature reports where "electrocatalysis" has been reported with no clear control experiments undertaken. On the other hand true electrocatalysis is observed towards hydrazine, where no such voltammetric features are witnessed on the bare underlying electrode substrate.

  3. Cobalt Phthalocyanine Modified Electrodes Utilised in Electroanalysis: Nano-Structured Modified Electrodes vs. Bulk Modified Screen-Printed Electrodes

    Directory of Open Access Journals (Sweden)

    Christopher W. Foster

    2014-11-01

    Full Text Available Cobalt phthalocyanine (CoPC compounds have been reported to provide electrocatalytic performances towards a substantial number of analytes. In these configurations, electrodes are typically constructed via drop casting the CoPC onto a supporting electrode substrate, while in other cases the CoPC complex is incorporated within the ink of a screen-printed sensor, providing a one-shot economical and disposable electrode configuration. In this paper we critically compare CoPC modified electrodes prepared by drop casting CoPC nanoparticles (nano-CoPC onto a range of carbon based electrode substrates with that of CoPC bulk modified screen-printed electrodes in the sensing of the model analytes L-ascorbic acid, oxygen and hydrazine. It is found that no “electrocatalysis” is observed towards L-ascorbic acid using either of these CoPC modified electrode configurations and that the bare underlying carbon electrode is the origin of the obtained voltammetric signal, which gives rise to useful electroanalytical signatures, providing new insights into literature reports where “electrocatalysis” has been reported with no clear control experiments undertaken. On the other hand true electrocatalysis is observed towards hydrazine, where no such voltammetric features are witnessed on the bare underlying electrode substrate.

  4. Impedance pneumography using textile electrodes.

    Science.gov (United States)

    Fiedler, P; Biller, S; Griebel, S; Haueisen, J

    2012-01-01

    The acquisition of physiological parameters using textile and textile-integrated sensors has become an important alternative for mobile and long-term monitoring. We analyzed to different commercially available electrically conductive textiles concerning their applicability for textile-based impedance pneumography. We immersed the textiles to four corroding solutions and observed no considerable changes in the absolute value as well as the phase shift of the material impedances. Subsequently, we performed impedance pneumography tests with different current amplitudes and frequencies. Using silver coated synthetic textile electrodes it was possible to detect the correct respiration frequency during normal, flat as well as slow, deep respiration.

  5. Aluminum-carbon composite electrode

    Science.gov (United States)

    Farahmandi, C.J.; Dispennette, J.M.

    1998-07-07

    A high performance double layer capacitor having an electric double layer formed in the interface between activated carbon and an electrolyte is disclosed. The high performance double layer capacitor includes a pair of aluminum impregnated carbon composite electrodes having an evenly distributed and continuous path of aluminum impregnated within an activated carbon fiber preform saturated with a high performance electrolytic solution. The high performance double layer capacitor is capable of delivering at least 5 Wh/kg of useful energy at power ratings of at least 600 W/kg. 3 figs.

  6. Aluminum-carbon composite electrode

    Science.gov (United States)

    Farahmandi, C. Joseph; Dispennette, John M.

    1998-07-07

    A high performance double layer capacitor having an electric double layer formed in the interface between activated carbon and an electrolyte is disclosed. The high performance double layer capacitor includes a pair of aluminum impregnated carbon composite electrodes having an evenly distributed and continuous path of aluminum impregnated within an activated carbon fiber preform saturated with a high performance electrolytic solution. The high performance double layer capacitor is capable of delivering at least 5 Wh/kg of useful energy at power ratings of at least 600 W/kg.

  7. Silver manganese oxide electrodes for lithium batteries

    Science.gov (United States)

    Thackeray, Michael M.; Vaughey, John T.; Dees, Dennis W.

    2006-05-09

    This invention relates to electrodes for non-aqueous lithium cells and batteries with silver manganese oxide positive electrodes, denoted AgxMnOy, in which x and y are such that the manganese ions in the charged or partially charged electrodes cells have an average oxidation state greater than 3.5. The silver manganese oxide electrodes optionally contain silver powder and/or silver foil to assist in current collection at the electrodes and to improve the power capability of the cells or batteries. The invention relates also to a method for preparing AgxMnOy electrodes by decomposition of a permanganate salt, such as AgMnO4, or by the decomposition of KMnO4 or LiMnO4 in the presence of a silver salt.

  8. Amperometric noise at thin film band electrodes.

    Science.gov (United States)

    Larsen, Simon T; Heien, Michael L; Taboryski, Rafael

    2012-09-18

    Background current noise is often a significant limitation when using constant-potential amperometry for biosensor application such as amperometric recordings of transmitter release from single cells through exocytosis. In this paper, we fabricated thin-film electrodes of gold and conductive polymers and measured the current noise in physiological buffer solution for a wide range of different electrode areas. The noise measurements could be modeled by an analytical expression, representing the electrochemical cell as a resistor and capacitor in series. The studies revealed three domains; for electrodes with low capacitance, the amplifier noise dominated, for electrodes with large capacitances, the noise from the resistance of the electrochemical cell was dominant, while in the intermediate region, the current noise scaled with electrode capacitance. The experimental results and the model presented here can be used for choosing an electrode material and dimensions and when designing chip-based devices for low-noise current measurements.

  9. Electrocatalytic activity of bismuth doped silver electrodes

    CERN Document Server

    Amjad, M

    2002-01-01

    Investigation of redox reactions on silver, and bismuth doped silver electrodes in aqueous KOH solutions, by using potentiostatic steady-state polarization technique, has been carried out. The redox wave potential and current displacements along with multiplicity of the latter have been examined. These electrodes were employed for the oxidation of organic molecules such as ethylamine in alkaline media. Subsequently, these electrodes were ranked with respect to their activity for the redox reactions. (author)

  10. Alkaline Electrochemical Capacitor and Electrode Fabrication

    National Research Council Canada - National Science Library

    Finello, D

    1999-01-01

    .... The subject low cost alkaline electrochemical capacitor designs are based upon titanium nitride electrodes which exhibit 125 mF/sq cm surface capacitance density and remarkable electrochemical...

  11. FUEL CELL ELECTRODES FOR ACID MEDIA

    Science.gov (United States)

    fuel cell electrodes for acid media. Activated carbon electrodes were prepared, wetproofed with paraffin or Teflon, and catalyzed with platinum. The wetproofing agent was applied by immersion or electrodeposition and the catalyst applied by chemical decomposition of H2P+Cl6 solutions. Half cell studies with hydrogen anodes and oxygen (air) cathodes showed that electrochemical performance is essentially the same for paraffin and Teflontreated electrodes; however, the life of the Teflon-treated electrodes under equal conditions of load is greater than that for

  12. Charged Water Droplets can Melt Metallic Electrodes

    Science.gov (United States)

    Elton, Eric; Rosenberg, Ethan; Ristenpart, William

    2016-11-01

    A water drop, when immersed in an insulating fluid, acquires charge when it contacts an energized electrode. Provided the electric field is strong enough, the drop will move away to the opposite electrode, acquire the opposite charge, and repeat the process, effectively 'bouncing' back and forth between the electrodes. A key implicit assumption, dating back to Maxwell, has been that the electrode remains unaltered by the charging process. Here we demonstrate that the electrode is physically deformed during each charge transfer event with an individual water droplet or other conducting object. We used optical, electron, and atomic force microscopy to characterize a variety of different metallic electrodes before and after drops were electrically bounced on them. Although the electrodes appear unchanged to the naked eye, the microscopy reveals that each charge transfer event yielded a crater approximately 1 micron wide and 50 nm deep, with the exact dimensions proportional to the applied field strength. We present evidence that the craters are formed by localized melting of the electrodes via Joule heating in the metal and concurrent dielectric breakdown of the surrounding fluid, suggesting that the electrode locally achieves temperatures exceeding 3400°C. Present address: Dept. Materials Sci. Engineering, MIT.

  13. Fabricating solid carbon porous electrodes from powders

    Science.gov (United States)

    Kaschmitter, James L.; Tran, Tri D.; Feikert, John H.; Mayer, Steven T.

    1997-01-01

    Fabrication of conductive solid porous carbon electrodes for use in batteries, double layer capacitors, fuel cells, capacitive dionization, and waste treatment. Electrodes fabricated from low surface area (Electrodes having a higher surface area, fabricated from powdered carbon blacks, such as carbon aerogel powder, carbon aerogel microspheres, activated carbons, etc. yield high conductivity carbon compositives with excellent double layer capacity, and can be used in double layer capacitors, or for capacitive deionization and/or waste treatment of liquid streams. By adding metallic catalysts to be high surface area carbons, fuel cell electrodes can be produced.

  14. Carbon aerogel electrodes for direct energy conversion

    Science.gov (United States)

    Mayer, Steven T.; Kaschmitter, James L.; Pekala, Richard W.

    1997-01-01

    A direct energy conversion device, such as a fuel cell, using carbon aerogel electrodes, wherein the carbon aerogel is loaded with a noble catalyst, such as platinum or rhodium and soaked with phosphoric acid, for example. A separator is located between the electrodes, which are placed in a cylinder having plate current collectors positioned adjacent the electrodes and connected to a power supply, and a pair of gas manifolds, containing hydrogen and oxygen positioned adjacent the current collectors. Due to the high surface area and excellent electrical conductivity of carbon aerogels, the problems relative to high polarization resistance of carbon composite electrodes conventionally used in fuel cells are overcome.

  15. Electrode assemblies, plasma apparatuses and systems including electrode assemblies, and methods for generating plasma

    Science.gov (United States)

    Kong, Peter C; Grandy, Jon D; Detering, Brent A; Zuck, Larry D

    2013-09-17

    Electrode assemblies for plasma reactors include a structure or device for constraining an arc endpoint to a selected area or region on an electrode. In some embodiments, the structure or device may comprise one or more insulating members covering a portion of an electrode. In additional embodiments, the structure or device may provide a magnetic field configured to control a location of an arc endpoint on the electrode. Plasma generating modules, apparatus, and systems include such electrode assemblies. Methods for generating a plasma include covering at least a portion of a surface of an electrode with an electrically insulating member to constrain a location of an arc endpoint on the electrode. Additional methods for generating a plasma include generating a magnetic field to constrain a location of an arc endpoint on an electrode.

  16. Polystyrene Based Silver Selective Electrodes

    Directory of Open Access Journals (Sweden)

    Shiva Agarwal

    2002-06-01

    Full Text Available Silver(I selective sensors have been fabricated from polystyrene matrix membranes containing macrocycle, Me6(14 diene.2HClO4 as ionophore. Best performance was exhibited by the membrane having a composition macrocycle : Polystyrene in the ratio 15:1. This membrane worked well over a wide concentration range 5.0×10-6–1.0×10-1M of Ag+ with a near-Nernstian slope of 53.0 ± 1.0 mV per decade of Ag+ activity. The response time of the sensor is <15 s and the membrane can be used over a period of four months with good reproducibility. The proposed electrode works well in a wide pH range 2.5-9.0 and demonstrates good discriminating power over a number of mono-, di-, and trivalent cations. The sensor has also been used as an indicator electrode in the potentiometric titration of silver(II ions against NaCl solution. The sensor can also be used in non-aqueous medium with no significant change in the value of slope or working concentration range for the estimation of Ag+ in solution having up to 25% (v/v nonaqueous fraction.

  17. Determination of the Resistance of Cone-Shaped Solid Electrodes

    DEFF Research Database (Denmark)

    Frandsen, Henrik Lund; Hendriksen, Peter Vang; Koch, Søren

    2017-01-01

    during processing can be avoided. Newman's formula for current constriction in the electrolyte is then used to deduce the active contact area based on the ohmic resistance of the cell, and from this the surface specific electro-catalytic activity. However, for electrode materials with low electrical...... conductivity (like Ce1-xPrxO2-δ), the resistance of the cell is significantly influenced by the ohmic resistance of the cone electrode, wherefore it must be included. In this work the ohmic resistance of a cone is modelled analytically based on simplified geometries. The two analytical models only differ...... by a model specific pre-factor, which is consequently determined by a finite element model. The model was applied to measurements on cones of Ce1-xPrxO2-δ  characterized on an YSZ electrolyte. Conclusively, the finite element model was used to obtain a formula for the resistance for different cone angles...

  18. High temperature SU-8 pyrolysis for fabrication of carbon electrodes

    DEFF Research Database (Denmark)

    Hassan, Yasmin Mohamed; Caviglia, Claudia; Hemanth, Suhith

    2017-01-01

    In this work, we present the investigation of the pyrolysis parameters at high temperature (1100 °C) for the fabrication of two-dimensional pyrolytic carbon electrodes. The electrodes were fabricated by pyrolysis of lithographically patterned negative epoxy based photoresist SU-8. A central...... composite experimental design was used to identify the influence of dwell time at the highest pyrolysis temperature and heating rate on electrical, electrochemical and structural properties of the pyrolytic carbon: Van der Pauw sheet resistance measurements, cyclic voltammetry, electrochemical impedance...... spectroscopy and Raman spectroscopy were used to characterize the pyrolytic carbon. The results show that the temperature increase from 900 °C to 1100 °C improves the electrical and electrochemical properties. At 1100 °C, longer dwell time leads to lower resistivity, while the variation of the pyrolysis...

  19. Simultaneous Production of High-Performance Flexible Textile Electrodes and Fiber Electrodes for Wearable Energy Storage.

    Science.gov (United States)

    Dong, Liubing; Xu, Chengjun; Li, Yang; Wu, Changle; Jiang, Baozheng; Yang, Qian; Zhou, Enlou; Kang, Feiyu; Yang, Quan-Hong

    2016-02-24

    High-performance flexible textile electrodes and fiber electrodes are produced simultaneously by a newly proposed effective strategy. Activated carbon fiber cloth (ACFC)/carbon nanotubes (CNTs) and ACFC/MnO2/CNTs composites are designed as high-performance flexible textile electrodes. Theses textiles can also be easily dismantled into individual fiber bundles used as high-performance flexible fiber electrodes. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Dual Approach to Amplify Anodic Stripping Voltammetric Signals Recorded Using Screen Printed Electrodes

    Directory of Open Access Journals (Sweden)

    Agnieszka KRÓLICKA

    2016-12-01

    Full Text Available Screen printed electrodes plated with bismuth were used to record anodic stripping voltammograms of Pb(II, In(III and Cd(II. Using two bismuth precursors: Bi2O3 dispersed in the electrode body and Bi(III ions spiked into the tested solution it was possible to deposit bismuth layers, demonstrating exceptional ability to accumulate metals forming alloys with bismuth. The voltammetric signals were amplified by adjusting the electrode location with respect to rotating magnetic field. The electrode response was influenced by vertical and horizontal distance between the magnet center and the sensing area of screen printed electrode as well as the angle between the magnet surface and the electrode. When the electrode was moved away from the magnet center the recorded peaks were increasingly smaller and almost not affected by the presence of bismuth ions. It was shown that to obtain well-shaped signals a favourable morphology of bismuth deposits is of key importance. Hypotheses explaining processes responsible for the amplification of voltammetric signals were proposed.

  1. The Impact of a Cochlear Implant Electrode Array on the Middle Ear Transfer Function.

    Science.gov (United States)

    Pazen, David; Anagiotos, Andreas; Nünning, Maike; Gostian, Antoniu-Oreste; Ortmann, Magdalene; Beutner, Dirk

    As a treatment for partial deafness with residual hearing in the lower frequency range, the combined acoustic and electric stimulation of the cochlea has become widespread. Acoustic stimulation is provided by a hearing aid's airborne sound and the electric stimulation by a cochlear implant electrode array, which may be inserted through the round window or a cochleostomy. To take advantage of that concept, it is essential to preserve residual hearing after surgery. Therefore, the intracochlear electrode array should not compromise the middle ear vibration transmission. This study investigates the influence of different electrode types and insertion paths on the middle ear transfer function and the inner ear fluid dynamics. Sound-induced oval and round window net volume velocities were calculated from vibration measurements with laser vibrometers on six nonfixated human temporal bones. After baseline measurements in the "natural" condition, a cochleostomy was drilled and closed with connective tissue. Then, four different electrode arrays were inserted through the cochleostomy. Afterwards, they were inserted through the round window while the cochleostomy was patched again with connective tissue. After having drilled a cochleostomy and electrode insertion, no systematic trends in the changes of oval and round window volume velocities were observed. Nearly all changes of middle ear transfer functions, as well as oval and round window volume velocity ratios, were statistically insignificant. Intracochlear electrode arrays do not significantly increase cochlear input impedance immediately after insertion. Any changes that may occur seem to be independent of electrode array type and insertion path.

  2. A Novel AED Electrode Design Significantly Improves Laypersons Abillities to Correctly Place AED Electrodes

    DEFF Research Database (Denmark)

    Bødtker, Henrik; Stærk, Mathilde; Glerup Lauridsen, Kasper

    2017-01-01

    electrode designs on a 10 point-scale. The primary endpoint was ratio of correct left apical AED electrode placement defined as ≤5 cm from the recommended position.Results: In total, 84 participants were randomized to novel (n=39, female: 62% median age: 41.5 years (±10.3)) and standard (n=45, female: 64......% median age: 43.5 (±8.2)) electrodes. The left apical AED electrode placement was improved when using novel electrodes with pictures compared with standard electrodes (51% vs 18%, (P<0.0001). No significant difference in right AED electrode placement was observed. Time to AED electrode placement...... was faster using novel electrodes with pictures (difference: 7.9 sec, P<0.0001). User-friendliness was rated higher in novel AED electrodes with pictures compared to conventional electrodes (9 (8;10) vs. 7 (6;8)) (P=0.001).Conclusion: A novel AED electrode design with pictures results in faster and better...

  3. Production of Manual Metal Arc Welding Electrodes with Local Raw ...

    African Journals Online (AJOL)

    The basic characteristic test criteria for determining the performance of any electrode were carried out. ... It was observed that manganese based flux covered electrode (a local electrode) with tensile strength of 585.8 N/mm2 was able to compete effectively with titanium dioxide based electrode (a foreign electrode) with ...

  4. A comparison of conductive textile-based and silver/silver chloride gel electrodes in exercise electrocardiogram recordings.

    Science.gov (United States)

    Marozas, Vaidotas; Petrenas, Andrius; Daukantas, Saulius; Lukosevicius, Arunas

    2011-01-01

    The goal of this study was to compare disposable silver/silver chloride and reusable conductive textile-based electrodes in electrocardiogram (ECG) signal monitoring during physical activity. The reusable electrodes were produced using thin silver-plated nylon 117/17 2-ply conductive thread (Statex Productions & Vertriebs GmbH, Bremen, Germany) sewed with a sewing machine on a chest belt. The disposable and reusable electrodes were compared in vivo according to ECG signal baseline drift, broadband electrode noise properties, and influence of electrode area to ECG signal morphology and frequency content. Twelve volunteers were included in this study. Electroconductive textile-based ECG electrodes produce significantly more noise in a very low frequency band (0-0.67 Hz) and not significantly less of broadband noise (0-250 Hz) than disposable silver/silver chloride electrodes. Decreasing area of textile electrodes decreases fidelity of registered ECG signals at low frequencies. Textile electrodes having adequate area can be used in more applications than only R-R interval monitoring. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. The Graphene/l-Cysteine/Gold-Modified Electrode for the Differential Pulse Stripping Voltammetry Detection of Trace Levels of Cadmium

    Directory of Open Access Journals (Sweden)

    Yu Song

    2016-06-01

    Full Text Available Cadmium(II is a common water pollutant with high toxicity. It is of significant importance for detecting aqueous contaminants accurately, as these contaminants are harmful to human health and environment. This paper describes the fabrication, characterization, and application of an environment-friendly graphene (Gr/l-cysteine/gold electrode to detect trace levels of cadmium (Cd by differential pulse stripping voltammetry (DPSV. The influence of hydrogen overflow was decreased and the current response was enhanced because the modified graphene extended the potential range of the electrode. The Gr/l-cysteine/gold electrode showed high electrochemical conductivity, producing a marked increase in anodic peak currents (vs. the glass carbon electrode (GCE and boron-doped diamond (BDD electrode. The calculated detection limits are 1.15, 0.30, and 1.42 µg/L, and the sensitivities go up to 0.18, 21.69, and 152.0 nA·mm−2·µg−1·L for, respectively, the BDD electrode, the GCE, and the Gr/l-cysteine/gold electrode. It was shown that the Gr/l-cysteine/gold-modified electrode is an effective means for obtaining highly selective and sensitive electrodes to detect trace levels of cadmium.

  6. Optimization of spin-coated electrodes for electrolyte-supported solid oxide fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Nobrega, Shayenne Diniz da; Monteiro, Natalia Kondo; Tabuti, Francisco; Fonseca, Fabio Coral, E-mail: shaynnedn@hotmail.com, E-mail: nataliakm@usp.br, E-mail: fntabuti@ipen.br, E-mail: fabiocf@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Sao Paulo, SP (Brazil); Florio, Daniel Zanetti de, E-mail: daniel.florio@ufabc.edu.br [Universidade Federal do ABC (UFABC), Santo Andre, SP (Brazil)

    2017-01-15

    Electrodes for electrolyte-supported solid oxide fuel cells (SOFC’s) were fabricated by spin coating. Strontium-doped lanthanum manganite (LSM) cathode and nickel yttria-stabilized zirconia cermet anodes were synthesized and processed for enhanced deposition conditions. The influence of electrode microstructural parameters was investigated by a systematic experimental procedure aiming at optimized electrochemical performance of single cells. Polarization curves showed a strong dependence on both electrode thickness and sintering temperature. By a systematic control of such parameters, the performance of single cells was significantly enhanced due to decreasing of polarization resistance from 26 Ω cm² to 0.6 Ω cm² at 800°C. The results showed that spin-coated electrodes can be optimized for fast and cost effective fabrication of SOFCs. (author)

  7. Carbon Nanotubes Counter Electrode for Dye-Sensitized Solar Cells Application

    Directory of Open Access Journals (Sweden)

    Drygała A.

    2016-06-01

    Full Text Available The influence of the carbon nanotubes counter electrode deposited on the FTO glass substrates on the structure and optoelectrical properties of dye-sensitized solar cells counter electrode (CE was analysed. Carbon materials have been applied in DSSC s in order to produce low-cost solar cells with reasonable efficiency. Platinum is a preferred material for the counter electrode because of its high conductivity and catalytic activity. However, the costs of manufacturing of the platinum counter electrode limit its use to large-scale applications in solar cells. This paper presents the results of examining the structure and properties of the studied layers, defining optical properties of conductive layers and electrical properties of dye-sensitized solar cells manufactured with the use of carbon nanotubes.

  8. Electrode modifications to lower electrode impedance and improve neural signal recording sensitivity

    Science.gov (United States)

    Chung, T.; Wang, J. Q.; Wang, J.; Cao, B.; Li, Y.; Pang, S. W.

    2015-10-01

    Objective. Although electrode size should be miniaturized to provide higher selectivity for neural signal recording and to avoid tissue damage, small sized electrodes induce high impedance, which decreases recording quality. In this work, the electrode surface was modified to increase the effective surface area to lower the electrode impedance and to improve the neural signal detection quality by optimizing plasma conditions. Approach. A tetrafluoromethane (CF4) plasma was used to increase the effective surface area of gold electrode sites of polyimide-based neural probes. In vitro electrode impedance and in vivo neural signal recording and stimulation were characterized. Main results. For 15 μm diameter (dia.) electrode size, the average surface roughness could be increased from 1.7 to 22 nm after plasma treatment, and the electrode impedance was decreased by 98%. Averaged background noise power in the range of 1 to 1000 Hz was decreased to -106 dB after the 30 μm dia. electrodes were plasma modified—lower than the noise level of -86 dB without plasma treatment. Neural probes with plasma-modified electrode sites of 15 and 30 μm dia. were implanted to the anterior cingulate cortex (ACC) region for acute recording of spontaneous and electrical evoked local field potential (LFP) of neural signals. Spontaneous LFP recorded in vivo by the plasma-modified electrodes of 30 μm dia. was two times higher compared to electrodes without treatment. For a stimulation current of 400 μA, electrically evoked LFP recorded by the plasma-modified electrodes was seven times higher than those without plasma exposure. Significance. A controllable technology was developed to increase the effective surface area of electrodes using a CF4 plasma. Plasma-modified electrodes improved the quality of the neural probe recording and more sensitive to record spontaneous and evoked LFP in the ACC region.

  9. Low Energy Desalination Using Battery Electrode Deionization

    KAUST Repository

    Kim, Taeyoung

    2017-09-21

    New electrochemical technologies that use capacitive or battery electrodes are being developed to minimize energy requirements for desalinating brackish waters. When a pair of electrodes is charged in capacitive deionization (CDI) systems, cations bind to the cathode and anions bind to the anode, but high applied voltages (>1.2 V) result in parasitic reactions and irreversible electrode oxidation. In the battery electrode deionization (BDI) system developed here, two identical copper hexacyanoferrate (CuHCF) battery electrodes were used that release and bind cations, with anion separation occurring via an anion exchange membrane. The system used an applied voltage of 0.6 V, which avoided parasitic reactions, achieved high electrode desalination capacities (up to 100 mg-NaCl/g-electrode, 50 mM NaCl influent), and consumed less energy than CDI. Simultaneous production of desalinated and concentrated solutions in two channels avoided a two-cycle approach needed for CDI. Stacking additional membranes between CuHCF electrodes (up to three anion and two cation exchange membranes) reduced energy consumption to only 0.02 kWh/m3 (approximately an order of magnitude lower than values reported for CDI), for an influent desalination similar to CDI (25 mM decreased to 17 mM). These results show that BDI could be effective as a very low energy method for brackish water desalination.

  10. Reverse electrodialysis : evaluation of suitable electrode systems

    NARCIS (Netherlands)

    Veerman, J.; Saakes, M.; Metz, S. J.; Harmsen, G. J.

    Reverse electrodialysis (RED) is a method for directly extracting electrical energy from salinity gradients, especially from sea and river water. For the commercial implementation of RED, the electrode system is a key component. In this paper, novel electrode systems for RED were compared with

  11. Microneedle array electrode for human EEG recording.

    NARCIS (Netherlands)

    Lüttge, Regina; van Nieuwkasteele-Bystrova, Svetlana Nikolajevna; van Putten, Michel Johannes Antonius Maria; Vander Sloten, Jos; Verdonck, Pascal; Nyssen, Marc; Haueisen, Jens

    2009-01-01

    Microneedle array electrodes for EEG significantly reduce the mounting time, particularly by circumvention of the need for skin preparation by scrubbing. We designed a new replication process for numerous types of microneedle arrays. Here, polymer microneedle array electrodes with 64 microneedles,

  12. Testing of Electrodes, Cells and Short Stacks

    DEFF Research Database (Denmark)

    Hauch, Anne; Mogensen, Mogens Bjerg

    2017-01-01

    The present contribution describes the electrochemical testing and characterization of electrodes, cells, and short stacks. To achieve the maximum insight and results from testing of electrodes and cells, it is obviously necessary to have a good understanding of the fundamental principles...

  13. Doped graphene electrodes for organic solar cells

    International Nuclear Information System (INIS)

    Park, Hyesung; Kim, Ki Kang; Bulovic, Vladimir; Kong, Jing; Rowehl, Jill A

    2010-01-01

    In this work graphene sheets grown by chemical vapor deposition (CVD) with controlled numbers of layers were used as transparent electrodes in organic photovoltaic (OPV) devices. It was found that for devices with pristine graphene electrodes, the power conversion efficiency (PCE) is comparable to their counterparts with indium tin oxide (ITO) electrodes. Nevertheless, the chances for failure in OPVs with pristine graphene electrodes are higher than for those with ITO electrodes, due to the surface wetting challenge between the hole-transporting layer and the graphene electrodes. Various alternative routes were investigated and it was found that AuCl 3 doping on graphene can alter the graphene surface wetting properties such that a uniform coating of the hole-transporting layer can be achieved and device success rate can be increased. Furthermore, the doping both improves the conductivity and shifts the work function of the graphene electrode, resulting in improved overall PCE performance of the OPV devices. This work brings us one step further toward the future use of graphene transparent electrodes as a replacement for ITO.

  14. Nanometer-spaced electrodes with calibrated separation

    NARCIS (Netherlands)

    Kervennic, Y.V.; Van der Zant, H.S.J.; Morpurgo, A.F.; Gurevich, L.; Kouwenhoven, L.P.

    2002-01-01

    We have fabricated pairs of platinum electrodes with separation between 20 and 3.5 nm. Our technique combines electron beam lithography and chemical electrodeposition. We show that the measurement of the conductance between the two electrodes through the electrolyte provides an accurate and

  15. APPLICATIONS OF A SINGLE CARBON ELECTRODE

    African Journals Online (AJOL)

    Preferred Customer

    applications: welding, spot welding, hole piercing, etc. The metal tube holding the carbon electrodes is banded with a piece of copper tubing that has been flattened into a strap and fitted with a screw for tightening. The perpendicular free end of the copper strap is inserted into the jaws of the electrode holder of an arc welder ...

  16. Synthesis of carbon nanotubes bridging metal electrodes

    International Nuclear Information System (INIS)

    Kotlar, M.; Vojs, M.; Marton, M.; Vesel, M.; Redhammer, R.

    2012-01-01

    In our work we demonstrate growth of carbon nanotubes that can conductively bridge the metal electrodes. The role of different catalysts was examined. Interdigitated metal electrodes are made from copper and we are using bimetal Al/Ni as catalyst for growth of carbon nanotubes. We are using this catalyst composition for growth of the single-walled carbon nanotube network. (authors)

  17. Composite supercapacitor electrodes made of activated carbon ...

    Indian Academy of Sciences (India)

    ... in PEDOT improved the storage performance of the composite electrode well over that of PEDOT:PSS. The composite electrodes were characterized for their electrochemical behaviour, structural and morphological details and electronic conductivity and showed promise as high-performance energy storage systems.

  18. mwnts composite film modified glassy carbon electrode

    African Journals Online (AJOL)

    Preferred Customer

    ABSTRACT: A poly p-aminosalicylic acid (Poly(p-ASA)) and multiwall carbon nanotubes. (MWCNTs) composite modified glassy carbon (GC) electrode was constructed by casting the MWNTs on the GC electrode surface followed by electropolymerization of the p-ASA on the MWCNTs/GCE. The electrochemical behaviours ...

  19. Bipolar Electrode Sample Preparation Devices

    Science.gov (United States)

    Wang, Yi (Inventor); Song, Hongjun (Inventor); Pant, Kapil (Inventor)

    2017-01-01

    An analyte selection device can include: a body defining a fluid channel having a channel inlet and channel outlet; a bipolar electrode (BPE) between the inlet and outlet; one of an anode or cathode electrically coupled with the BPE on a channel inlet side of the BPE and the other of the anode or cathode electrically coupled with the BPE on a channel outlet side of the BPE; and an electronic system operably coupled with the anode and cathode so as to polarize the BPE. The fluid channel can have any shape or dimension. The channel inlet and channel outlet can be longitudinal or lateral with respect to the longitudinal axis of the channel. The BPE can be any metallic member, such as a flat plate on a wall or mesh as a barrier BPE. The anode and cathode can be located at a position that polarizes the BPE.

  20. Platinum Porous Electrodes for Fuel Cells

    DEFF Research Database (Denmark)

    Andersen, Shuang Ma

    Fuel cell energy bears the merits of renewability, cleanness and high efficiency. Proton Exchange Membrane Fuel Cell (PEMFC) is one of the most promising candidates as the power source in the near future. A fine management of different transports and electrochemical reactions in PEM fuel cells...... determination; morphology; oxidation state of components and stability.  Electrode composition investigation: optimization on ionomer content and electrode protonic conductivity.  Interaction between electrode components  Morphology of electrode surface and MEA cross section. The above efforts all contribute...... to a genuine picture of a working PEM fuel cell catalyst layer. These, in turn, enrich the knowledge of Three-Phase-Boundary, provide efficient tool for the electrode selection and eventually will contribute the advancement of PEMFC technology....

  1. Pierce electrodes for a multigap accelerating system

    International Nuclear Information System (INIS)

    Davydenko, V.I.; Ivanov, A.A.; Kotelnikov, I.A.; Tiunov, M.A.

    2007-01-01

    A well-known Pierce's solution that allows to focus a beam of charged particles using properly shaped electrodes outside the beam is generalized to the case of multigap accelerating system. Simple parametric formulae for Pierce electrodes are derived for an accelerating system with current density, limited either by space charge or by emitting property of the cathode. As an example of general approach, Pierce electrodes shape is analyzed for a system with two accelerating gaps. It is shown that precise Pierce's solution exists if acceleration rate within second gap is lower than within first gap. In the opposite case quasi-Pierce solution can be implemented using non-equipotential electrode between the gaps, and guidelines, based on numerical simulations, for the design of equipotential focusing electrodes are given

  2. Textile electrode characterization: dependencies in the skin-clothing-electrode interface

    International Nuclear Information System (INIS)

    Macías, R; Fernández, M; Bragós, R

    2013-01-01

    Given the advances in the technology known as smart textiles, the use of textile electrodes is more and more common. However this kind of electrodes presents some differences regarding the standard ones as the Ag-AgCl electrodes. Therefore to characterize them as best as possible is required. In order to make the characterization reproducible and repetitive, a skin dummy made of agar-agar and a standardized measurement set-up is used in this article. Thus, some dependencies in the skin-electrode interface are described. These dependencies are related to the surface of the textile electrode, the conductive material and the applied pressure. Furthermore, the dependencies on clothing in the skin-textile electrode interface are also analyzed. Thus, based on some parameters such as textile material, width and number of layers, the behavior of the interface made up by the skin, the textile electrode and clothing is depicted.

  3. Textile electrode characterization: dependencies in the skin-clothing-electrode interface

    Science.gov (United States)

    Macías, R.; Fernández, M.; Bragós, R.

    2013-04-01

    Given the advances in the technology known as smart textiles, the use of textile electrodes is more and more common. However this kind of electrodes presents some differences regarding the standard ones as the Ag-AgCl electrodes. Therefore to characterize them as best as possible is required. In order to make the characterization reproducible and repetitive, a skin dummy made of agar-agar and a standardized measurement set-up is used in this article. Thus, some dependencies in the skin-electrode interface are described. These dependencies are related to the surface of the textile electrode, the conductive material and the applied pressure. Furthermore, the dependencies on clothing in the skin-textile electrode interface are also analyzed. Thus, based on some parameters such as textile material, width and number of layers, the behavior of the interface made up by the skin, the textile electrode and clothing is depicted.

  4. Electrode assembly for a lithium ion battery, process for the production of such electrode assembly, and lithium ion battery comprising such electrode assemblies

    NARCIS (Netherlands)

    Mulder, F.M.; Wagemaker, M.

    2013-01-01

    The invention provides an electrode assembly for a lithium ion battery, the electrode assembly comprising a lithium storage electrode layer on a current collector, wherein the lithium storage electrode layer is a porous layer having a porosity in the range of -35 %, with pores having pore widths in

  5. Two Proximal Skin Electrodes — A Respiration Rate Body Sensor

    Directory of Open Access Journals (Sweden)

    Viktor Avbelj

    2012-10-01

    Full Text Available We propose a new body sensor for extracting the respiration rate based on the amplitude changes in the body surface potential differences between two proximal body electrodes. The sensor could be designed as a plaster-like reusable unit that can be easily fixed onto the surface of the body. It could be equipped either with a sufficiently large memory for storing the measured data or with a low-power radio system that can transmit the measured data to a gateway for further processing. We explore the influence of the sensor’s position on the quality of the extracted results using multi-channel ECG measurements and considering all the pairs of two neighboring electrodes as potential respiration-rate sensors. The analysis of the clinical measurements, which also include reference thermistor-based respiration signals, shows that the proposed approach is a viable option for monitoring the respiration frequency and for a rough classification of breathing types. The obtained results were evaluated on a wireless prototype of a respiration body sensor. We indicate the best positions for the respiration body sensor and prove that a single sensor for body surface potential difference on proximal skin electrodes can be used for combined measurements of respiratory and cardiac activities.

  6. A density functional theory study of the carbon-coating effects on lithium iron borate battery electrodes

    DEFF Research Database (Denmark)

    Loftager, Simon; García Lastra, Juan Maria; Vegge, Tejs

    2017-01-01

    a density functional theory (DFT) study of the anchoring configurations of carbon coating on the LiFeBO3 electrode and its implications on the interfacial lithium diffusion. Due to large barriers associated with Li-ion diffusion through a parallel-oriented pristine graphene coating on the FeBO3 and LiFeBO3...... coating on the electrode which also improves the electronic conductivity. However, not much is known about the preferential geometries of the coating as well as how these coating–electrode interfaces influence the lithium diffusion between the coating and the electrode. Here, we therefore present...... electrode surfaces, large structural defects in the graphene coating are required for fast Li-ion diffusion. However, such defects are expected to exist only in small concentrations due to their high formation energies. Alternative coating geometries were therefore investigated, and the configuration...

  7. Comparison of the voltammetric behavior of metronidazole at a DNA-modified glassy carbon electrode, a mercury thin film electrode and a glassy carbon electrode

    OpenAIRE

    Brett, Ana Maria Oliveira; Serrano, Silvia H. P.; Gutz, Ivano G. R.; La-Scalea, Mauro A.

    1997-01-01

    The electroanalytical performance at three electrodes: DNA-modified galssy carbon electrode, mercury thin film electrode and glassy carbon electrode, for the study of the electrochemical reduction of metronidazole is compared. All three electrodes showed a similar trend in the reduction mechanism for metronidazole, depenent on pH in the acid and neutral region and independent in alkaline media, although there was a shift in the peak potentials to more negative values when a bare glassy carbon...

  8. Rational design of new electrodes for electrochemotherapy.

    Science.gov (United States)

    Spugnini, E P; Citro, G; Porrello, A

    2005-06-01

    Electrochemotherapy associates the local delivery of anticancer drugs with the administration of permeabilizing electric pulses that support the antiblastic action. The basic instrumentation for this therapy is constituted by a pulse generator and various specific electrodes. While many efforts have been profuse by researchers in this field to obtain the standardization of the pulse generating equipment over the past 15 years, the delivery apparatus still needs refinements in order to reach most of the body districts, to control the homogeneity and stability of the electric fields and to further reduce morbidity. With the aim to develop innovative electrodes able to satisfy, at least partially, these requirements, extensive studies on pet patients with spontaneous neoplasms have been conducted, leading to the manufacturing of several different prototypes. In this paper we discuss the rationale of 11 different electrodes, briefly summarize the results obtained and their experimental validation, also presenting five paradigmatic clinical cases. In particular, it is shown that the caliper electrodes are more suited for the treatment of cutaneous and subcutaneous lesions, while the needle arrays are more efficacious in intraoperative settings. Furthermore, relevant peculiarities of unipolar electrodes are examined with a particular focus on the irregular current paths that they produce and on the potentialities of this feature. Remarkably, the decrease of the steric encumbrance turned out to be a stronger factor in electrode design than the containment of the total number of electric fields covered in serial ECT sessions. In the conclusions, perspectives and new challenges of electrode design for electrochemotherapy are illustrated.

  9. Chlorophyll assembled electrode for photovoltaic conversion device

    Energy Technology Data Exchange (ETDEWEB)

    Amao, Yutaka; Kato, Koichi [Department of Applied Chemistry, Oita University, 700 Dannoharu, Oita 870-1192 (Japan)

    2007-11-20

    Chlorophyll-a (Chl-a) assembled in hydrophobic domain by fatty acid with long alkyl hydrocarbon chain such as myristic acid (Myr), stearic acid (Ste) and cholic acid (Cho) modified onto nanocrystalline TiO{sub 2} electrode is prepared and the photovoltaic properties of the nanocrystalline TiO{sub 2} film by Chl-a are studied. Incident photon to current efficiency (IPCE) value at 660 nm in photocurrent action spectrum of Chl-a/Ste-TiO{sub 2}, Chl-a/Myr-TiO{sub 2} and Chl-a/Cho-TiO{sub 2} electrodes are 5.0%, 4.1% and 4.1%, respectively. Thus, the IPCE is maximum using Chl-a/Ste-TiO{sub 2} electrode. From the results of photocurrent responses with light intensity of 100 mW cm{sup -2} irradiation or monochromatic light with 660 nm, generated photocurrent increases using Chl-a/Ste-TiO{sub 2} electrode compared with the other Chl-a assembled TiO{sub 2} electrodes. These results show that the hydrophobic domain formed by stearic acid with long alkyl hydrocarbon chain is suitable for fixation of Chl-a onto TiO{sub 2} film electrodes and photovoltaic performance is improved using Chl-a onto Ste-TiO{sub 2} film electrode. (author)

  10. Nanostructured Solid Oxide Fuel Cell Electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Sholklapper, Tal Zvi [Univ. of California, Berkeley, CA (United States)

    2007-01-01

    The ability of Solid Oxide Fuel Cells (SOFC) to directly and efficiently convert the chemical energy in hydrocarbon fuels to electricity places the technology in a unique and exciting position to play a significant role in the clean energy revolution. In order to make SOFC technology cost competitive with existing technologies, the operating temperatures have been decreased to the range where costly ceramic components may be substituted with inexpensive metal components within the cell and stack design. However, a number of issues have arisen due to this decrease in temperature: decreased electrolyte ionic conductivity, cathode reaction rate limitations, and a decrease in anode contaminant tolerance. While the decrease in electrolyte ionic conductivities has been countered by decreasing the electrolyte thickness, the electrode limitations have remained a more difficult problem. Nanostructuring SOFC electrodes addresses the major electrode issues. The infiltration method used in this dissertation to produce nanostructure SOFC electrodes creates a connected network of nanoparticles; since the method allows for the incorporation of the nanoparticles after electrode backbone formation, previously incompatible advanced electrocatalysts can be infiltrated providing electronic conductivity and electrocatalysis within well-formed electrolyte backbones. Furthermore, the method is used to significantly enhance the conventional electrode design by adding secondary electrocatalysts. Performance enhancement and improved anode contamination tolerance are demonstrated in each of the electrodes. Additionally, cell processing and the infiltration method developed in conjunction with this dissertation are reviewed.

  11. Characterization of positive electrode/electrolyte interphase in lithium batteries

    Energy Technology Data Exchange (ETDEWEB)

    Dupre, N.; Martin, J.F.; Soudan, P.; Guyomard, D. [Inst.des Materiaux Jean Rouxel, Nantes (France)

    2008-07-01

    Lithium batteries appear to be the most viable energy source for portable electronic devices because of their energy density. The solid electrolyte interphase (SEI) between the negative electrode and the electrolyte of a Li-ion battery monitors the overall battery behaviour in terms of irreversible capacity loss, charge transfer kinetics and storage properties. This paper reported on a study that examined the influence of the storage atmosphere and the formation of a protective surface layer on the electrochemical performance. The objective was to better understand the interfacial problems controlling the long term life duration and cyclability. The positive/electrolyte interphase evolution was followed upon aging/cycling using 7Li MAS NMR, XPS and impedance spectroscopy. This very novel and uncommon technique was used to characterize the growth and evolution of the surface of some electrode materials for lithium batteries, due to contact with the ambient atmosphere or electrolyte or along electrochemical cycling. LiFePO4 and LiMn0.5Ni0.5O2 were chosen for the studies because they are among the most promising candidates for positive electrodes for future lithium batteries. The reaction of LiMn0.5Ni0.5O2 with the ambient atmosphere or LiPF6 electrolyte is extremely fast and leads to an important amount of lithium-containing diamagnetic species. The NMR spectra provided valuable structural information on the interaction between the interphase and the active material after contact with electrolyte or along electrochemical cycling. MAS NMR was shown to be a very promising tool to monitor phenomena taking place at the interface between electrode and electrolyte in lithium batteries. The study showed the affect of the potential on the strength of the interaction between the surface layer and the active material and the partial removal of this layer along the electrochemical cycling. 11 refs.

  12. Design, fabrication and skin-electrode contact analysis of polymer microneedle-based ECG electrodes

    Science.gov (United States)

    O'Mahony, Conor; Grygoryev, Konstantin; Ciarlone, Antonio; Giannoni, Giuseppe; Kenthao, Anan; Galvin, Paul

    2016-08-01

    Microneedle-based ‘dry’ electrodes have immense potential for use in diagnostic procedures such as electrocardiography (ECG) analysis, as they eliminate several of the drawbacks associated with the conventional ‘wet’ electrodes currently used for physiological signal recording. To be commercially successful in such a competitive market, it is essential that dry electrodes are manufacturable in high volumes and at low cost. In addition, the topographical nature of these emerging devices means that electrode performance is likely to be highly dependent on the quality of the skin-electrode contact. This paper presents a low-cost, wafer-level micromoulding technology for the fabrication of polymeric ECG electrodes that use microneedle structures to make a direct electrical contact to the body. The double-sided moulding process can be used to eliminate post-process via creation and wafer dicing steps. In addition, measurement techniques have been developed to characterize the skin-electrode contact force. We perform the first analysis of signal-to-noise ratio dependency on contact force, and show that although microneedle-based electrodes can outperform conventional gel electrodes, the quality of ECG recordings is significantly dependent on temporal and mechanical aspects of the skin-electrode interface.

  13. Design, fabrication and skin-electrode contact analysis of polymer microneedle-based ECG electrodes

    International Nuclear Information System (INIS)

    O’Mahony, Conor; Grygoryev, Konstantin; Ciarlone, Antonio; Giannoni, Giuseppe; Kenthao, Anan; Galvin, Paul

    2016-01-01

    Microneedle-based ‘dry’ electrodes have immense potential for use in diagnostic procedures such as electrocardiography (ECG) analysis, as they eliminate several of the drawbacks associated with the conventional ‘wet’ electrodes currently used for physiological signal recording. To be commercially successful in such a competitive market, it is essential that dry electrodes are manufacturable in high volumes and at low cost. In addition, the topographical nature of these emerging devices means that electrode performance is likely to be highly dependent on the quality of the skin-electrode contact.This paper presents a low-cost, wafer-level micromoulding technology for the fabrication of polymeric ECG electrodes that use microneedle structures to make a direct electrical contact to the body. The double-sided moulding process can be used to eliminate post-process via creation and wafer dicing steps. In addition, measurement techniques have been developed to characterize the skin-electrode contact force. We perform the first analysis of signal-to-noise ratio dependency on contact force, and show that although microneedle-based electrodes can outperform conventional gel electrodes, the quality of ECG recordings is significantly dependent on temporal and mechanical aspects of the skin-electrode interface. (paper)

  14. Cadmium electrode and process for its production

    Energy Technology Data Exchange (ETDEWEB)

    Rampel, G.G.; Puglisi, V.J.

    1991-11-12

    This patent describes a cadmium electrode for use in a rechargeable cell employing an alkaline electrolyte. It comprises an electrically conductive substrate supporting an electrochemically active material; an interconnecting network of aliphatic alcohol soluble polyamide, the solubility limit of the polyamide in n- propanol being at least about 7.4 percent by weight, linked to the substrate and serving as a binder and an anti- agglomerant retarding cadmium agglomeration during use of the electrode; and a mixture of particulate electrochemically active cadmium material retained in and dispersed through the network and in electrical contact with the substrate during charge and discharge of the electrode.

  15. Conducting polymer electrodes for gel electrophoresis.

    Directory of Open Access Journals (Sweden)

    Katarina Bengtsson

    Full Text Available In nearly all cases, electrophoresis in gels is driven via the electrolysis of water at the electrodes, where the process consumes water and produces electrochemical by-products. We have previously demonstrated that π-conjugated polymers such as poly(3,4-ethylenedioxythiophene (PEDOT can be placed between traditional metal electrodes and an electrolyte to mitigate electrolysis in liquid (capillary electroosmosis/electrophoresis systems. In this report, we extend our previous result to gel electrophoresis, and show that electrodes containing PEDOT can be used with a commercial polyacrylamide gel electrophoresis system with minimal impact to the resulting gel image or the ionic transport measured during a separation.

  16. Conducting polymer electrodes for gel electrophoresis.

    Science.gov (United States)

    Bengtsson, Katarina; Nilsson, Sara; Robinson, Nathaniel D

    2014-01-01

    In nearly all cases, electrophoresis in gels is driven via the electrolysis of water at the electrodes, where the process consumes water and produces electrochemical by-products. We have previously demonstrated that π-conjugated polymers such as poly(3,4-ethylenedioxythiophene) (PEDOT) can be placed between traditional metal electrodes and an electrolyte to mitigate electrolysis in liquid (capillary electroosmosis/electrophoresis) systems. In this report, we extend our previous result to gel electrophoresis, and show that electrodes containing PEDOT can be used with a commercial polyacrylamide gel electrophoresis system with minimal impact to the resulting gel image or the ionic transport measured during a separation.

  17. Ultratransparent and stretchable graphene electrodes

    Science.gov (United States)

    Liu, Nan; Chortos, Alex; Lei, Ting; Jin, Lihua; Kim, Taeho Roy; Bae, Won-Gyu; Zhu, Chenxin; Wang, Sihong; Pfattner, Raphael; Chen, Xiyuan; Sinclair, Robert; Bao, Zhenan

    2017-01-01

    Two-dimensional materials, such as graphene, are attractive for both conventional semiconductor applications and nascent applications in flexible electronics. However, the high tensile strength of graphene results in fracturing at low strain, making it challenging to take advantage of its extraordinary electronic properties in stretchable electronics. To enable excellent strain-dependent performance of transparent graphene conductors, we created graphene nanoscrolls in between stacked graphene layers, referred to as multilayer graphene/graphene scrolls (MGGs). Under strain, some scrolls bridged the fragmented domains of graphene to maintain a percolating network that enabled excellent conductivity at high strains. Trilayer MGGs supported on elastomers retained 65% of their original conductance at 100% strain, which is perpendicular to the direction of current flow, whereas trilayer films of graphene without nanoscrolls retained only 25% of their starting conductance. A stretchable all-carbon transistor fabricated using MGGs as electrodes exhibited a transmittance of >90% and retained 60% of its original current output at 120% strain (parallel to the direction of charge transport). These highly stretchable and transparent all-carbon transistors could enable sophisticated stretchable optoelectronics. PMID:28913422

  18. Three-dimensional micro-electrode array for recording dissociated neuronal cultures.

    Science.gov (United States)

    Musick, Katherine; Khatami, David; Wheeler, Bruce C

    2009-07-21

    This work demonstrates the design, fabrication, packaging, characterization, and functionality of an electrically and fluidically active three-dimensional micro-electrode array (3D MEA) for use with neuronal cell cultures. The successful function of the device implies that this basic concept-construction of a 3D array with a layered approach-can be utilized as the basis for a new family of neural electrode arrays. The 3D MEA prototype consists of a stack of individually patterned thin films that form a cell chamber conducive to maintaining and recording the electrical activity of a long-term three-dimensional network of rat cortical neurons. Silicon electrode layers contain a polymer grid for neural branching, growth, and network formation. Along the walls of these electrode layers lie exposed gold electrodes which permit recording and stimulation of the neuronal electrical activity. Silicone elastomer micro-fluidic layers provide a means for loading dissociated neurons into the structure and serve as the artificial vasculature for nutrient supply and aeration. The fluidic layers also serve as insulation for the micro-electrodes. Cells have been shown to survive in the 3D MEA for up to 28 days, with spontaneous and evoked electrical recordings performed in that time. The micro-fluidic capability was demonstrated by flowing in the drug tetrotodoxin to influence the activity of the culture.

  19. Investigation on power discharge in micro-EDM stainless steel drilling using different electrodes

    International Nuclear Information System (INIS)

    D'Urso, G.; Maccarini, G.; Quarto, M.; Ravasio, C.

    2015-01-01

    The present work deals with the execution of through micro-holes on stainless steel plates using a micro-EDM (Electrical discharge machining) machine. The investigation focuses on the influence of different electrodes' materials and power discharge on both the process performance and the dimensional characteristics of the holes. The experimental campaign was carried out by varying peak current and voltage in order to achieve both high and low power discharge conditions. Tubular electrodes made of three different materials (tungsten carbide, brass and copper) were used. The indexes taken into account were Material removal rate (MRR), Tool wear ratio (TWR), Diametral overcut (DOC) and Taper rate (TR). Brass and copper electrodes always resulted to be the best solution in terms of drilling speed even though the wear of these electrode types is remarkable higher than the tungsten one. On the opposite, tungsten carbide electrodes resulted to be the best solution when high dimensional and geometrical precision is required. Concerning the finishing of the hole inner surface, the best results were achieved using tungsten carbide electrode.

  20. AC surface flashover strength and barrier effect of LN 2 for HTS transformer with simulated electrode

    Science.gov (United States)

    Joung, Jong-Man; Baek, Seung-Myeong; Kim, Hae-Jong; Kim, Sang-Hyun

    2003-10-01

    In the response to an increasing demand for electrical energy, much effort aimed to develop and commercialise HTS power equipments is going on around the world. For the development, it is necessary to establish the dielectric technology in LN 2. Hence many types of dielectric tests should be carried out to understand the dielectric phenomena at cryogenic temperature and to gather various dielectric data. Among the many types dielectric tests, the characteristic of surface flashover and the barrier effect were conducted with the simulated electrode after analysing the insulating configuration of the pancake-coil-type HTS transformer. The influence of a barrier on the dielectric strength was measured according to the size of the barrier, the position of the barrier and the effect of the back-electrode. It was shown that the effectiveness, namely the ratio of the breakdown voltage in presence of barrier to the voltage without barrier, is highest when the barrier is placed at the needle electrode side. The effect increased up to 1.8 times when collar length is 10 mm. The flashover characteristic with back-electrode was remarkably lower than the characteristic without one in the case the electrodes located at the same surface of dielectric plate. On the contrary, in the case the barrier was placed between the electrodes, the characteristic was even improved slightly.

  1. Changes in Carbon Electrode Morphology Affect Microbial Fuel Cell Performance with Shewanella oneidensis MR-1

    Directory of Open Access Journals (Sweden)

    David V. P. Sanchez

    2015-03-01

    Full Text Available The formation of biofilm-electrodes is crucial for microbial fuel cell current production because optimal performance is often associated with thick biofilms. However, the influence of the electrode structure and morphology on biofilm formation is only beginning to be investigated. This study provides insight on how changing the electrode morphology affects current production of a pure culture of anode-respiring bacteria. Specifically, an analysis of the effects of carbon fiber electrodes with drastically different morphologies on biofilm formation and anode respiration by a pure culture (Shewanella oneidensis MR-1 were examined. Results showed that carbon nanofiber mats had ~10 fold higher current than plain carbon microfiber paper and that the increase was not due to an increase in electrode surface area, conductivity, or the size of the constituent material. Cyclic voltammograms reveal that electron transfer from the carbon nanofiber mats was biofilm-based suggesting that decreasing the diameter of the constituent carbon material from a few microns to a few hundred nanometers is beneficial for electricity production solely because the electrode surface creates a more relevant mesh for biofilm formation by Shewanella oneidensis MR-1.

  2. Characterization of carbon pastes as matrices in composite electrodes for use in electrochemical capacitors.

    Directory of Open Access Journals (Sweden)

    M. Miranda-Hernandez

    2008-06-01

    Full Text Available Carbon paste electrodes (CPEs were prepared from carbon black powder with different binders (Silicon Oil or Nujol.Cyclic voltammetry, chronoamperometry and chronopotentiometry techniques and different electrolytes (1M HClO4 and 1MLiClO4 were used to characterize the capacitive response and evaluate the capacitance (F/cm2, F/g of CPEs, with andwithout surface modification. The surface modification was carried out by applying a potential pulse (1.35 V vs. saturatedcalomel electrode, SCE at a time of 300 s, where the growth of carbon-oxygen (C-O species were induced on the surface ofthe electrode. The results show that modified electrodes enhanced the capacitance and the electrolytic system has animportant influence in the stability and reactivity of electrodes. The modified electrodes shows an importantpseudocapacitive behavior as result of a diffusion processes that involved an interfacial reaction between the C-O speciesformed during the electrochemical surface treatment and the protons present in the electrolyte.

  3. Electrode Induced Removal and Recovery of Uranium (VI) from Acidic Subsurfaces

    Energy Technology Data Exchange (ETDEWEB)

    Gregory, Kelvin [Carnegie Mellon University

    2013-08-12

    The overarching objective of this research is to provide an improved understanding of how aqueous geochemical conditions impact the removal of U and Tc from groundwater and how engineering design may be utilized to optimize removal of these radionuclides. Experiments were designed to address the unique conditions in Area 3 of ORNL while also providing broader insight into the geochemical effectors of the removal rates and extent for U and Tc. The specific tasks of this work were to: 1) quantify the impact of common aqueous geochemical and operational conditions on the rate and extent of U removal and recovery from water, 2) investigate the removal of Tc with polarized graphite electrode, and determine the influence of geochemical and operational conditions on Tc removal and recovery, 3) determine whether U and Tc may be treated simultaneous from Area 3 groundwater, and examine the bench-scale performance of electrode-based treatment, and 4) determine the capacity of graphite electrodes for U(VI) removal and develop a mathematical, kinetic model for the removal of U(VI) from aqueous solution. Overall the body of work suggests that an electrode-based approach for the remediation of acidic subsurface environments, such as those observed in Area 3 of ORNL may be successful for the removal for both U(VI) and Tc. Carbonaceous (graphite) electrode materials are likely to be the least costly means to maximize removal rates and efficiency by maximizing the electrode surface area.

  4. Schiff bases as cadmium(II) selective ionophores in polymeric membrane electrodes

    International Nuclear Information System (INIS)

    Gupta, V.K.; Singh, A.K.; Gupta, Barkha

    2007-01-01

    The construction and performance characteristics of polymeric membrane electrodes based on two neutral ionophores, N,N'-[bis(pyridin-2-yl)formylidene]butane-1,4-diamine (S 1 ) and N-(2-pyridinylmethylene)-1,2-benzenediamine (S 2 ) for quantification of cadmium ions, are described. The influences of membrane compositions on the potentiometric response of the electrodes have been found to substantially improve the performance characteristics. The best performance was obtained with the electrode having a membrane composition (w/w) of (S 1 ) (2.15%):PVC (32.2%):o-NPOE (64.5%):KTpClPB (1.07%). The proposed electrode exhibits Nernstian response in the concentration range of 7.9 x 10 -8 to 1.0 x 10 -1 M Cd 2+ with limit of detection 5.0 x 10 -8 M, performs satisfactorily over wide pH range (2.0-8.0) with a fast response time (10 s). The sensor has been found to work satisfactorily in partially non-aqueous media up to 30% (v/v) content of methanol, ethanol and acetonitrile and could be used for a period of 2 months. The analytical usefulness of the proposed electrode has been evaluated by its application in the determination of cadmium in real samples. The practical utility of the membrane electrode has also been observed in the presence of surfactants

  5. Schiff bases as cadmium(II) selective ionophores in polymeric membrane electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, V.K. [Department of Chemistry, Indian Institute of Technology-Roorkee, Roorkee 247667 (India)]. E-mail: vinodfcy@iitr.ernet.in; Singh, A.K. [Department of Chemistry, Indian Institute of Technology-Roorkee, Roorkee 247667 (India); Gupta, Barkha [Department of Chemistry, Indian Institute of Technology-Roorkee, Roorkee 247667 (India)

    2007-02-05

    The construction and performance characteristics of polymeric membrane electrodes based on two neutral ionophores, N,N'-[bis(pyridin-2-yl)formylidene]butane-1,4-diamine (S{sub 1}) and N-(2-pyridinylmethylene)-1,2-benzenediamine (S{sub 2}) for quantification of cadmium ions, are described. The influences of membrane compositions on the potentiometric response of the electrodes have been found to substantially improve the performance characteristics. The best performance was obtained with the electrode having a membrane composition (w/w) of (S{sub 1}) (2.15%):PVC (32.2%):o-NPOE (64.5%):KTpClPB (1.07%). The proposed electrode exhibits Nernstian response in the concentration range of 7.9 x 10{sup -8} to 1.0 x 10{sup -1} M Cd{sup 2+} with limit of detection 5.0 x 10{sup -8} M, performs satisfactorily over wide pH range (2.0-8.0) with a fast response time (10 s). The sensor has been found to work satisfactorily in partially non-aqueous media up to 30% (v/v) content of methanol, ethanol and acetonitrile and could be used for a period of 2 months. The analytical usefulness of the proposed electrode has been evaluated by its application in the determination of cadmium in real samples. The practical utility of the membrane electrode has also been observed in the presence of surfactants.

  6. Displacement and resonance behaviors of a piezoelectric diaphragm driven by a double-sided spiral electrode

    KAUST Repository

    Shen, Zhiyuan

    2012-04-03

    This paper presents the design of a lead zirconate titanate (PZT) diaphragm actuated by double-sided patterned electrodes. Au/Cr electrodes were deposited on bulk PZT wafers by sputtering while patterned by a lift-off process. SU-8 thick film was used to form the structural layer. Double-spiral electrode induced in-plane poling and piezoelectric elongation are converted to an out-of-plane displacement due to the confined boundary condition. The influence of different drive configurations and electrode parameters on deflection has been calculated by finite element methods (FEM) using a uniform field model. Impedance and quasi-static displacement spectra of the diaphragm were measured after poling. Adouble-sided patterned electrode diaphragm can be actuated by more drive configurations than a single-sided one. Compared with a single-sided electrode drive, a double-sided out-of-phase drive configuration increases the coupling coefficient of the fundamental resonance from 7.6% to 11.8%. The displacement response of the diaphragm increases from 2.6 to 8.6nmV 1. Configurations including the electric field component perpendicular to the poling direction can stimulate shear modes of the diaphragm. © 2012 IOP Publishing Ltd.

  7. High Electrocatalytic Response of a Mechanically Enhanced NbC Nanocomposite Electrode Towards Hydrogen Evolution Reaction

    KAUST Repository

    Coy, Emerson

    2017-08-22

    Resistant and efficient electrocatalysts for hydrogen evolution reaction (HER) are desired to replace scarce and commercially expensive platinum electrodes. Thin film electrodes of metal-carbides are a promising alternative due to their reduced price and similar catalytic properties. However, most of the studied structures to date neglect long lasting chemical and structural stability, focusing only on electrochemical efficiency. Herein we report on a new approach to easily deposit and control the micro/nanostructure of thin film electrodes based on niobium carbide (NbC) and their electrocatalytic response. We will show that, by improving the mechanical properties of the NbC electrodes, microstructure and mechanical resilience can be obtained whilst maintaining high electro catalytic response. We also address the influence of other parameters such as conductivity and chemical composition on the overall performance of the thin film electrodes. Finally, we show that nanocomposite NbC electrodes are promising candidates towards HER , and furthermore, that the methodology presented here is suitable to produce other transition metal carbides (TM-C) with improved catalytic and mechanical properties.

  8. Enhanced performance of electrospun carbon fibers modified with carbon nanotubes: promising electrodes for enzymatic biofuel cells.

    Science.gov (United States)

    Engel, A Both; Cherifi, A; Tingry, S; Cornu, D; Peigney, A; Laurent, Ch

    2013-06-21

    New nanostructured electrodes, promising for the production of clean and renewable energy in biofuel cells, were developed with success. For this purpose, carbon nanofibers were produced by the electrospinning of polyacrylonitrile solution followed by convenient thermal treatments (stabilization followed by carbonization at 1000, 1200 and 1400° C), and carbon nanotubes were adsorbed on the surfaces of the fibers by a dipping method. The morphology of the developed electrodes was characterized by several techniques (SEM, Raman spectroscopy, electrical conductivity measurement). The electrochemical properties were evaluated through cyclic voltammetry, where the influence of the carbonization temperature of the fibers and the beneficial contribution of the carbon nanotubes were observed through the reversibility and size of the redox peaks of K3Fe(CN)6 versus Ag/AgCl. Subsequently, redox enzymes were immobilized on the electrodes and the electroreduction of oxygen to water was realized as a test of their efficiency as biocathodes. Due to the fibrous and porous structure of these new electrodes, and to the fact that carbon nanotubes may have the ability to promote electron transfer reactions of redox biomolecules, the new electrodes developed were capable of producing higher current densities than an electrode composed only of electrospun carbon fibers.

  9. The interactive electrode localization utility: software for automatic sorting and labeling of intracranial subdural electrodes.

    Science.gov (United States)

    LaPlante, Roan A; Tang, Wei; Peled, Noam; Vallejo, Deborah I; Borzello, Mia; Dougherty, Darin D; Eskandar, Emad N; Widge, Alik S; Cash, Sydney S; Stufflebeam, Steven M

    2017-10-01

    Existing methods for sorting, labeling, registering, and across-subject localization of electrodes in intracranial encephalography (iEEG) may involve laborious work requiring manual inspection of radiological images. We describe a new open-source software package, the interactive electrode localization utility which presents a full pipeline for the registration, localization, and labeling of iEEG electrodes from CT and MR images. In addition, we describe a method to automatically sort and label electrodes from subdural grids of known geometry. We validated our software against manual inspection methods in twelve subjects undergoing iEEG for medically intractable epilepsy. Our algorithm for sorting and labeling performed correct identification on 96% of the electrodes. The sorting and labeling methods we describe offer nearly perfect performance and the software package we have distributed may simplify the process of registering, sorting, labeling, and localizing subdural iEEG grid electrodes by manual inspection.

  10. Cochlear Implant Electrode Effect on Sound Energy Transfer Within the Cochlea During Acoustic Stimulation.

    Science.gov (United States)

    Greene, Nathaniel T; Mattingly, Jameson K; Jenkins, Herman A; Tollin, Daniel J; Easter, James R; Cass, Stephen P

    2015-09-01

    Cochlear implants (CIs) designed for hearing preservation will not alter mechanical properties of the middle and inner ears as measured by intracochlear pressure (P(IC)) and stapes velocity (Vstap). CIs designed to provide combined electroacoustic stimulation are now available. To maintain functional acoustic hearing, it is important to know if a CI electrode can alter middle or inner ear mechanics because any alteration could contribute to elevated low-frequency thresholds in electroacoustic stimulation patients. Seven human cadaveric temporal bones were prepared, and pure-tone stimuli from 120 Hz to 10 kHz were presented at a range of intensities up to 110 dB sound pressure level. P(IC) in the scala vestibuli (P(SV)) and tympani (PST) were measured with fiber-optic pressure sensors concurrently with VStap using laser Doppler vibrometry. Five CI electrodes from two different manufacturers with varying dimensions were inserted via a round window approach at six different depths (16-25 mm). The responses of P(IC) and VStap to acoustic stimulation were assessed as a function of stimulus frequency, normalized to sound pressure level in the external auditory canal, at baseline and electrode-inserted conditions. Responses measured with electrodes inserted were generally within approximately 5 dB of baseline, indicating little effect of CI electrode insertion on P(IC) and VStap. Overall, mean differences across conditions were small for all responses, and no substantial differences were consistently visible across electrode types. Results suggest that the influence of a CI electrode on middle and inner ear mechanics is minimal despite variation in electrode lengths and configurations.

  11. Carbon Nanotube Web with Carboxylated Polythiophene "Assist" for High-Performance Battery Electrodes.

    Science.gov (United States)

    Kwon, Yo Han; Park, Jung Jin; Housel, Lisa M; Minnici, Krysten; Zhang, Guoyan; Lee, Sujin R; Lee, Seung Woo; Chen, Zhongming; Noda, Suguru; Takeuchi, Esther S; Takeuchi, Kenneth J; Marschilok, Amy C; Reichmanis, Elsa

    2018-01-19

    A carbon nanotube (CNT) web electrode comprising magnetite spheres and few-walled carbon nanotubes (FWNTs) linked by the carboxylated conjugated polymer, poly[3-(potassium-4-butanoate) thiophene] (PPBT), was designed to demonstrate benefits derived from the rational consideration of electron/ion transport coupled with the surface chemistry of the electrode materials components. To maximize transport properties, the approach introduces monodispersed spherical Fe 3 O 4 (sFe 3 O 4 ) for uniform Li + diffusion and a FWNT web electrode frame that affords characteristics of long-ranged electronic pathways and porous networks. The sFe 3 O 4 particles were used as a model high-capacity energy active material, owing to their well-defined chemistry with surface hydroxyl (-OH) functionalities that provide for facile detection of molecular interactions. PPBT, having a π-conjugated backbone and alkyl side chains substituted with carboxylate moieties, interacted with the FWNT π-electron-rich and hydroxylated sFe 3 O 4 surfaces, which enabled the formation of effective electrical bridges between the respective components, contributing to efficient electron transport and electrode stability. To further induce interactions between PPBT and the metal hydroxide surface, polyethylene glycol was coated onto the sFe 3 O 4 particles, allowing for facile materials dispersion and connectivity. Additionally, the introduction of carbon particles into the web electrode minimized sFe 3 O 4 aggregation and afforded more porous FWNT networks. As a consequence, the design of composite electrodes with rigorous consideration of specific molecular interactions induced by the surface chemistries favorably influenced electrochemical kinetics and electrode resistance, which afforded high-performance electrodes for battery applications.

  12. Iodide selective membrane electrodes based on a Molybdenum-Salen as a neutral carrier

    Energy Technology Data Exchange (ETDEWEB)

    Ghanei-Motlagh, Masoud [Department of Chemistry, Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of); Taher, Mohammad Ali, E-mail: ma_taher@yahoo.com [Department of Chemistry, Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of); Ahmadi, Kyoumars [AJA University of Medical Sciences, Tehran (Iran, Islamic Republic of); Sheikhshoaie, Iran [Department of Chemistry, Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of)

    2011-12-01

    A new polymeric membrane electrode (PME) and a coated platinum disk electrode (CPtE) based on Schiff base complex of Mo(VI) as a suitable carrier for I{sup -} ion were described. The influence of membrane composition, pH and possible interfering anions were investigated on the response properties of the electrodes. The electrodes exhibited a Nernstian slope of 63.0 {+-} 0.5 (CPtE) and 60.3 {+-} 0.4 (PME) mV decade{sup -1} in I{sup -} ion over a wide concentration range from 7.9 x 10{sup -7} to 1.0 x 10{sup -1} M for CPtE and 9.1 x 10{sup -6} to 1.0 x 10{sup -1} M I{sup -} for PME. The potentiometric response of the electrodes was independent of the pH of the test solution in the pH range 2.0-8.5 with a fast response time (< 10 s). The process of transfer of iodide across the membrane interface was investigated by use of the AC impedance technique. The proposed sensors were successfully applied to direct determination of iodide in samples containing interfering anions, waste water and as indicator electrodes in precipitation titrations. Highlights: {yields} We study new selective membrane electrodes for iodide ions. {yields} To the best of our knowledge this is the first coated platinum disk electrode of I{sup -}. {yields} The sensors have a wide concentration range with a fast response time. {yields} Efforts have been made to improve the selectivity with the use of CPtE.

  13. Aging in chemically prepared divalent silver oxide electrodes for silver/zinc reserve batteries

    Science.gov (United States)

    Smith, David F.; Brown, Curtis

    The instability of silver(II) oxide electrodes used in silver/zinc reserve batteries is the well known cause of capacity loss and delayed activation in reserve batteries after they are stored in the dry, unactivated state for extended periods of time. Metal contaminants in sintered/electroformed electrodes destabilize the oxide and the solid state reaction between AgO and elemental silver results in the formation of the lower capacity monovalent oxide Ag 2O. Chemically prepared (CP) AgO can be used to avoid the metal contaminants and to minimize the interfacial contact area between AgO and Ag, thus minimizing the affects of aging on the electrodes. Electrodes were fabricated with CP AgO and polytetrafluoroethylene (PTFE) binder and expanded silver metal current collectors. Experimentally, both electrode active material compacts (AgO and binder only) and electrodes complete with AgO/binder and silver current collector were tested to evaluate the influence of the current collector on aging. The electrode samples were discharged at a constant rate of 50 mA cm -2 before and after storage at 60°C for 21 days as well as after storage at room ambient temperature conditions for 91 months. The results indicate that the affects of aging upon the AgO/binder compacts are insignificant for long term storage at room temperature. However, thermally accelerated aging at high temperature (60°C) affects both transient and stabilized load voltage as well as capacity. In terms of capacity, the AgO/binder mix itself looses about 5% capacity after 21 days dry storage at 60°C while electrodes complete with current collector loose about 8%. The 60% increase in capacity loss is attributed to the solid state reaction between AgO and elemental silver.

  14. Optimization of polymeric triiodide membrane electrode based on clozapine-triiodide ion-pair using experimental design.

    Science.gov (United States)

    Farhadi, Khalil; Bahram, Morteza; Shokatynia, Donya; Salehiyan, Floria

    2008-07-15

    Central composite design (CCD) and response surface methodology (RSM) were developed as experimental strategies for modeling and optimization of the influence of some variables on the performance of a new PVC membrane triiodide ion-selective electrode. This triiodide sensor is based on triiodide-clozapine ion-pair complexation. PVC, plasticizers, ion-pair amounts and pH were investigated as four variables to build a model to achieve the best Nernstian slope (59.9 mV) as response. The electrode is prepared by incorporating the ion-exchanger in PVC matrix plasticized with 2-nitrophenyl octal ether, which is directly coated on the surface of a graphite electrode. The influence of foreign ions on the electrode performance was also investigated. The optimized membranes demonstrate Nernstian response for triiodide ions over a wide linear range from 5.0 x 10(-6) to 1.0 x 10(-2)mol L(-1) with a limit of detection 2.0 x 10(-6) mol L(-1) at 25 degrees C. The electrodes could be used over a wide pH range 4-8, and have the advantages of easy to prepare, good selectivity and fast response time, long lifetime (over 3 months) and small interferences from hydrogen ion. The proposed electrode was successfully used as indicator electrode in potentiometric titration of triiodide ions and ascorbic acid.

  15. Steam activation of boron doped diamond electrodes

    International Nuclear Information System (INIS)

    Ohashi, Tatsuya; Zhang Junfeng; Takasu, Yoshio; Sugimoto, Wataru

    2011-01-01

    Highlights: → Steam activation of boron doped diamond (BDD) electrodes. → Steam activated BDD has a porous columnar texture. → Steam activated BDD has a wide potential window. - Abstract: Boron doped diamond (BDD) electrodes were activated in steam at various temperatures, resulting in high quality BDD electrodes with a porous microstructure. Distinct columnar structures were observed by scanning electron microscopy. The electrochemically active surface area of the steam-activated BDD was up to 20 times larger than the pristine BDD electrode owing to the porous texture. In addition, a widening of the potential window was observed after steam activation, suggesting that the quality of BDD was enhanced due to oxidative removal of graphitic impurities during the activation process.

  16. Wearable solar cells by stacking textile electrodes.

    Science.gov (United States)

    Pan, Shaowu; Yang, Zhibin; Chen, Peining; Deng, Jue; Li, Houpu; Peng, Huisheng

    2014-06-10

    A new and general method to produce flexible, wearable dye-sensitized solar cell (DSC) textiles by the stacking of two textile electrodes has been developed. A metal-textile electrode that was made from micrometer-sized metal wires was used as a working electrode, while the textile counter electrode was woven from highly aligned carbon nanotube fibers with high mechanical strengths and electrical conductivities. The resulting DSC textile exhibited a high energy conversion efficiency that was well maintained under bending. Compared with the woven DSC textiles that are based on wire-shaped devices, this stacked DSC textile unexpectedly exhibited a unique deformation from a rectangle to a parallelogram, which is highly desired in portable electronics. This lightweight and wearable stacked DSC textile is superior to conventional planar DSCs because the energy conversion efficiency of the stacked DSC textile was independent of the angle of incident light. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Use of lanthanide catalysts in air electrodes

    International Nuclear Information System (INIS)

    Souza Parente, L.T. de

    1982-01-01

    A review on the lanthanide catalysts suitable for the reduction catalysis of oxygen in air electrodes is presented. The kinds of lanthanide indicated to be used as catalysts of oxygen reduction are shown. (A.R.H.) [pt

  18. Ni-Based Solid Oxide Cell Electrodes

    DEFF Research Database (Denmark)

    Mogensen, Mogens Bjerg; Holtappels, Peter

    2013-01-01

    This paper is a critical review of the literature on nickel-based electrodes for application in solid oxide cells at temperature from 500 to 1000 _C. The applications may be fuel cells or electrolyser cells. The reviewed literature is that of experimental results on both model electrodes...... and practical composite cermet electrodes. A substantially longer three-phase boundary (TPB) can be obtained per unit area of cell in such a composite of nickel and electrolyte material, provided that two interwoven solid networks of the two solid and one gaseous phases are obtained to provide a three...... such as milling and sintering. The various electrode properties are deeply related to these parameters, but also much related to the atomic scale structure of the Ni-electrolyte interface, which in turn is affected by segregation of electrolyte components and impurities as well as poisons in the gas phase...

  19. Wearable Textile Electrodes for ECG Measurement

    Directory of Open Access Journals (Sweden)

    Lukas Vojtech

    2013-01-01

    Full Text Available The electrocardiogram (ECG is one of the most important parameters for monitoring of the physiological state of a person. Currently available systems for ECG monitoring are both stationary and wearable, but the comfort of the monitored person is not at a satisfactory level because these systems are not part of standard clothing. This article is therefore devoted to the development and measurement of wearable textile electrodes for ECG measurement device with high comfort for the user. The electrode material is made of electrically conductive textile. This creates a textile composite that guarantees high comfort for the user while ensuring good quality of ECG measurements. The composite is implemented by a carrier (a T-shirt with flame retardant and sensing electrodes embroidered with yarn based on a mixture of polyester coated with silver nanoparticles and cotton. The electrodes not only provide great comfort but are also antibacterial and antiallergic due to silver nanoparticles.

  20. Electrode geometry for electrostatic generators and motors

    Science.gov (United States)

    Post, Richard F.

    2016-02-23

    An electrostatic (ES) device is described with electrodes that improve its performance metrics. Devices include ES generators and ES motors, which are comprised of one or more stators (stationary members) and one or more rotors (rotatable members). The stator and rotors are configured as a pair of concentric cylindrical structures and aligned about a common axis. The stator and rotor are comprised of an ensemble of discrete, longitudinal electrodes, which are axially oriented in an annular arrangement. The shape of the electrodes described herein enables the ES device to function at voltages significantly greater than that of the existing art, resulting in devices with greater power-handling capability and overall efficiency. Electrode shapes include, but are not limited to, rods, corrugated sheets and emulations thereof.

  1. Field Emission Measurements from Niobium Electrodes

    Energy Technology Data Exchange (ETDEWEB)

    M. BastaniNejad, P.A. Adderley, J. Clark, S. Covert, J. Hansknecht, C. Hernandez-Garcia, R. Mammei, M. Poelker

    2011-03-01

    Increasing the operating voltage of a DC high voltage photogun serves to minimize space charge induced emittance growth and thereby preserve electron beam brightness, however, field emission from the photogun cathode electrode can pose significant problems: constant low level field emission degrades vacuum via electron stimulated desorption which in turn reduces photocathode yield through chemical poisoning and/or ion bombardment and high levels of field emission can damage the ceramic insulator. Niobium electrodes (single crystal, large grain and fine grain) were characterized using a DC high voltage field emission test stand at maximum voltage -225kV and electric field gradient > 10MV/m. Niobium electrodes appear to be superior to diamond-paste polished stainless steel electrodes.

  2. Advanced membrane electrode assemblies for fuel cells

    Science.gov (United States)

    Kim, Yu Seung; Pivovar, Bryan S.

    2012-07-24

    A method of preparing advanced membrane electrode assemblies (MEA) for use in fuel cells. A base polymer is selected for a base membrane. An electrode composition is selected to optimize properties exhibited by the membrane electrode assembly based on the selection of the base polymer. A property-tuning coating layer composition is selected based on compatibility with the base polymer and the electrode composition. A solvent is selected based on the interaction of the solvent with the base polymer and the property-tuning coating layer composition. The MEA is assembled by preparing the base membrane and then applying the property-tuning coating layer to form a composite membrane. Finally, a catalyst is applied to the composite membrane.

  3. Alkaline Electrochemical Capacitor and Electrode Fabrication

    National Research Council Canada - National Science Library

    Finello, D

    1999-01-01

    Highly capacitive (high surface area) electrodes that are electrochemically stable in strong alkaline electrolyte will form the basis for a new generation of electrical and electrochemical energy storage and conversion devices...

  4. Electrode placement during electro-desalination of

    DEFF Research Database (Denmark)

    Ottosen, Lisbeth M.; Andersson, Lovisa C. H.

    2017-01-01

    Carved stone sculptures and ornaments can be severely damaged by salt induced decay. Often the irregular surfaces are decomposed, and the artwork is lost. The present paper is an experimental investigation on the possibility for using electro-desalination for treatment of stone with irregular shape....... Electro-desalination experiments were made with different duration to follow the progress. Successful desalination of the whole stone piece was obtained, showing that also parts not being placed directly between the electrodes were desalinated. This is important in case of salt damaged carved stones......, where the most fragile parts thus can be desalinated without physically placing electrodes on them. The Cl removal rate was higher in the areas closest to the electrodes and slowest in the part, which was not placed directly between the electrodes. This is important to incorporate in the monitoring...

  5. Noble metals nanoparticles on titanium dioxide nanostructured films and the influence of their photocatalytic activity

    International Nuclear Information System (INIS)

    Nakamura, Liana Key Okada

    2012-01-01

    Currently, nanoscience and nanotechnology are considered an emerging field and continuously breaking the barrier among various disciplines. The main focus of study involves controlling structures at molecular level, arranging the atoms in order to achieve an understanding and controlling the fundamental properties of matter. In this study, molecular changes on the basis of morphology, optical and crystalline properties of TiO 2 hin films in order to increase their photon efficiency were proposed. The TiO 2 thin films were prepared by sol gel process evaluating the influence of different acids and templates to obtain the nano structured arrangements. Then, metal nanoparticles like Au, Ag, Pd and Pt were incorporated on TiO 2 thin films. This incorporation might minimize the electron-hole recombination, so it could improve the photon efficiency. From the several routes studied, the TiO 2 thin films prepared with acetic acid showed the best performance by the reason of low agglomeration of TiO 2 grains, which favors the exposure of the photoactive sites. The presence of template in the formulation had a slightly effect on photon efficiency, possible due to the higher agglomeration of the grains on the TiO 2 thin films. The addition of Pt and Au nanoparticles on TiO 2 thin films showed superior photon efficiency. The TiO 2 thin films with hexamine and metallic nanoparticles did not show the improvement on photon efficiency except for Pt and Au nanoparticles. On these situations, the improvement on photon efficiency is might be due to a possible decrease at the electron-hole recombination's velocity. Thus, the present work demonstrates the great influence of preparation conditions on the optical, morphological properties and the photon efficiency. In the future, with greater understanding of the mechanism of this influence, the properties of TiO 2 thin films will be able tailoring depending on the application. (author)

  6. Electrodeposition of polymer electrolyte in nanostructured electrodes for enhanced electrochemical performance of thin-film Li-ion microbatteries

    Science.gov (United States)

    Salian, Girish D.; Lebouin, Chrystelle; Demoulin, A.; Lepihin, M. S.; Maria, S.; Galeyeva, A. K.; Kurbatov, A. P.; Djenizian, Thierry

    2017-02-01

    We report that electrodeposition of polymer electrolyte in nanostructured electrodes has a strong influence on the electrochemical properties of thin-film Li-ion microbatteries. Electropolymerization of PMMA-PEG (polymethyl methacrylate-polyethylene glycol) was carried out on both the anode (self-supported titania nanotubes) and the cathode (porous LiNi0.5Mn1.5O4) by cyclic voltammetry and the resulting electrode-electrolyte interface was examined by scanning electron microscopy. The electrochemical characterizations performed by galvanostatic experiments reveal that the capacity values obtained at different C-rates are doubled when the electrodes are completely filled by the polymer electrolyte.

  7. Negative Electrodes for Li-Ion Batteries

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, Kim; Zaghib, Karim

    2001-10-01

    Graphitized carbons have played a key role in the successful commercialization of Li-ion batteries. The physicochemical properties of carbon cover a wide range; therefore identifying the optimum active electrode material can be time consuming. The significant physical properties of negative electrodes for Li-ion batteries are summarized, and the relationship of these properties to their electrochemical performance in nonaqueous electrolytes, are discussed in this paper.

  8. Ion-Selective Electrodes for Basic Drugs.

    Science.gov (United States)

    1981-01-01

    range from 10 M for cocaine and -6.0 Meth -slaMphetaMirne electrodes to 10 M for Methadone, and -6.5 10 M for protriptvline electrodes -I’Selectivit- is...t Wilson, J.E.O Olsen, G.D.; EBartos, F. Proc. West* PharMacol. Soc#,1979,22,463. 24) Mule , S.J*4 Bastos, M.L#O Jukovskv, D# Clin# Chem., 1974,20(2

  9. Printed optically transparent graphene cellulose electrodes

    Science.gov (United States)

    Sinar, Dogan; Knopf, George K.; Nikumb, Suwas; Andrushchenko, Anatoly

    2016-02-01

    Optically transparent electrodes are a key component in variety of products including bioelectronics, touch screens, flexible displays, low emissivity windows, and photovoltaic cells. Although highly conductive indium tin oxide (ITO) films are often used in these electrode applications, the raw material is very expensive and the electrodes often fracture when mechanically stressed. An alternative low-cost material for inkjet printing transparent electrodes on glass and flexible polymer substrates is described in this paper. The water based ink is created by using a hydrophilic cellulose derivative, carboxymethyl cellulose (CMC), to help suspend the naturally hydrophobic graphene (G) sheets in a solvent composed of 70% DI water and 30% 2-butoxyethanol. The CMC chain has hydrophobic and hydrophilic functional sites which allow adsorption on G sheets and, therefore, permit the graphene to be stabilized in water by electrostatic and steric forces. Once deposited on the functionalized substrate the electrical conductivity of the printed films can be "tuned" by decomposing the cellulose stabilizer using thermal reduction. The entire electrode can be thermally reduced in an oven or portions of the electrode thermally modified using a laser annealing process. The thermal process can reduce the sheet resistance of G-CMC films to < 100 Ω/sq. Experimental studies show that the optical transmittance and sheet resistance of the G-CMC conductive electrode is a dependent on the film thickness (ie. superimposed printed layers). The printed electrodes have also been doped with AuCl3 to increase electrical conductivity without significantly increasing film thickness and, thereby, maintain high optical transparency.

  10. Conducting Polymer Electrodes for Gel Electrophoresis

    OpenAIRE

    Bengtsson, Katarina; Nilsson, Sara; Robinson, Nathaniel D

    2014-01-01

    In nearly all cases, electrophoresis in gels is driven via the electrolysis of water at the electrodes, where the process consumes water and produces electrochemical by-products. We have previously demonstrated that p-conjugated polymers such as poly(3,4-ethylenedioxythiophene) (PEDOT) can be placed between traditional metal electrodes and an electrolyte to mitigate electrolysis in liquid (capillary electroosmosis/electrophoresis) systems. In this report, we extend our previous result to gel ...

  11. Analogy between electrochemical behaviour of thick silicon granular electrodes for lithium batteries and fine soils micromechanics

    International Nuclear Information System (INIS)

    Nguyen, B.P.N.; Gaubicher, J.; Lestriez, B.

    2014-01-01

    In this paper we study the influence of the distribution and the shape of the carbon conductive additives on the cyclability of thick silicon based composite electrodes. Results pinpoint the influence of carbon additives is not only to play on the electronic conductivity but also to play on the micromechanics (stress distribution) of the composite films. The lack of correlation between electrochemical performance and the macroscopic electronic conductivity of the pristine electrodes and the observation of repeated drops and jumps in capacity during cycling brought us to make an analogy between the silicon composite electrodes and cohesive granular materials such as fine soils media. Considering the collective mechanical behavior of a stack of silicon particles upon repeated volume variations shed a novel understanding to the electrochemical behavior of composite electrodes based on silicon and alloying materials and tells us how critically important is the design at the different scales (the particle, a few particles, the composite electrode, the cell) to engineer the mechanical stress and strain and improve cycle life

  12. Non-aqueous Electrode Processing and Construction of Lithium-ion Coin Cells.

    Science.gov (United States)

    Stein, Malcolm; Chen, Chien-Fan; Robles, Daniel J; Rhodes, Christopher; Mukherjee, Partha P

    2016-02-01

    Research into new and improved materials to be utilized in lithium-ion batteries (LIB) necessitates an experimental counterpart to any computational analysis. Testing of lithium-ion batteries in an academic setting has taken on several forms, but at the most basic level lies the coin cell construction. In traditional LIB electrode preparation, a multi-phase slurry composed of active material, binder, and conductive additive is cast out onto a substrate. An electrode disc can then be punched from the dried sheet and used in the construction of a coin cell for electrochemical evaluation. Utilization of the potential of the active material in a battery is critically dependent on the microstructure of the electrode, as an appropriate distribution of the primary components are crucial to ensuring optimal electrical conductivity, porosity, and tortuosity, such that electrochemical and transport interaction is optimized. Processing steps ranging from the combination of dry powder, wet mixing, and drying can all critically affect multi-phase interactions that influence the microstructure formation. Electrochemical probing necessitates the construction of electrodes and coin cells with the utmost care and precision. This paper aims at providing a step-by-step guide of non-aqueous electrode processing and coin cell construction for lithium-ion batteries within an academic setting and with emphasis on deciphering the influence of drying and calendaring.

  13. Investigation of top electrode for PZT thick films based MEMS sensors

    DEFF Research Database (Denmark)

    Hindrichsen, Christian Carstensen; Pedersen, Thomas; Kristiansen, Paw T.

    2010-01-01

    In this work processing of screen printed piezoelectric PZT thick films on silicon substrates is investigated for use in future MEMS devices. E-beam evaporated Al and Pt are patterned on PZT as a top electrode using a lift-off process with a line width down to 3 mu m. Three test structures are used...... to investigate the optimal thickness of the top electrode, the degradation of the piezoelectric properties of the PZT film in absence of a diffusion barrier layer and finally how to fabricate electrical interconnects down the edge of the PZT thick film. The roughness of the PZT is found to have a strong...... influence on the conductance of the top electrode influencing the optimal top electrode thickness. A 100 nm thick top electrode on the PZT thick film with a surface roughness of 273 nm has a 4.5 times higher resistance compared to a similar wire on a planar SiO2 surface which has a surface roughness of less...

  14. Access resistance of stimulation electrodes as a function of electrode proximity to the retina.

    Science.gov (United States)

    Majdi, Joseph A; Minnikanti, Saugandhika; Peixoto, Nathalia; Agrawal, Anant; Cohen, Ethan D

    2015-02-01

    Epiretinal prostheses seek to effectively stimulate the retina by positioning electrode arrays close to its surface so current pulses generate narrow retinal electric fields. Our objective was to evaluate the use of the electrical impedance of insulated platinum electrodes as a measure of the proximity of insulated platinum electrodes to the inner surface of the retina. We examined the impedance of platinum disk electrodes, 0.25 mm in diameter, insulated with two widths (0.8 and 1.6 mm outer diameter) of transparent fluoropolymer in a rabbit retinal eyecup preparation. Optical coherence tomography measured the electrode's proximity to the retinal surface which was correlated with changes in the voltage waveform at the electrode. Electrode impedance changes during retinal deformation were also studied. When the 1.6 mm diameter insulated electrodes advanced towards the retinal surface from 1000 μm, their voltage step at current pulse onset increased, reflecting an access resistance increase of 3880 ± 630 Ω, with the 50% midpoint averaging 30 μm, while thin 0.8 mm insulated electrode advancement showed an access resistance increase 50% midpoint averaging 16 μm. Using impedance spectroscopy, electrode-retina proximity differences were seen in the 1.6 mm insulated electrode impedance modulus between 1 and 100 kHz and the waveform phase angle at 0.3-10 kHz, while thin 0.8 mm insulated electrode advancement produced smaller impedance modulus changes with retinal proximity between 3 and 100 kHz. These impedance changes with retinal proximity may reflect different sized zones of eye wall being coupled in series with the insulated platinum electrode. The proximity of stimulus electrodes to neural tissue in fluid-filled spaces can be estimated from access resistance changes in the stimulus pulse waveform. Because many prosthetic devices allow back telemetry communication of the stimulus electrode waveform, it is possible these series resistance increases observed with

  15. Manufacturing process and electrode properties of palladium-electroded ionic polymer–metal composite

    International Nuclear Information System (INIS)

    Chang, Longfei; Chen, Hualing; Zhu, Zicai; Li, Bo

    2012-01-01

    This paper primarily focuses on the manufacturing process of palladium-electroded ionic polymer–metal composite (IPMC). First, according to the special properties of Pd, many experiments were done to determine several specific procedures, including the addition of a reducing agent and the time consumed. Subsequently, the effects of the core manufacturing steps on the electrode morphology were revealed by scanning electron microscopy studies of 22 IPMC samples treated with different combinations of manufacturing steps. Finally, the effects of electrode characteristics on the electromechanical properties, including the sheet resistivity, the elastic modulus and the electro-active performance, of IPMCs were evaluated experimentally and analyzed according to the electrode morphology. (paper)

  16. Multi-walled carbon nanotubes (MWCNT) as compliant electrodes for dielectric elastomer actuators

    Science.gov (United States)

    Chua, Soo-Lim; Neo, Xin-Hui; Lau, Gih-Keong

    2011-04-01

    A stacked dielectric elastomer actuator (DEA) consists of multiple layers of elastomeric dielectrics interleaved with compliant electrodes. It is capable of taking a tensile load if only the interleaving compliant electrodes provide a good bonding and enough elasticity. However, the stacked configuration of DEA was found to produce less actuation strain as compared to a single-layer configuration of pre-stretched membrane. It is believed the binder for compliant electrodes has a significant influence on the actuation strain. Yet, there has yet systematic study on the effect of binder. In this paper, we will study the effects of binder, solvent, and surface fictionalization on the compliant electrodes using the conductive filler of Multi-Walled Carbon Nanotube (MWCNT). Two types of binders are used, namely a soft silicone rubber (Mold Max 10T) and a soft silicone gel (Sylgard 527 gel). The present experiments show that the actuators using binders in the compliant electrodes produce a much lower areal strain as compared to the ones without binders in them. It is found that introducing a binder in the electrodes decreases the conductivity. The MWCNT compliant electrode with binder remains conductive (<1TΩ) up to a strain of 300%, whereas the one without binder remains conductive up to a strain of 800%. Changing the type of binder to a softer and less-viscous one increases the percolation ratio for MWCNT-COOH filler from 5% to 15% but this does not significantly increase the actuation strain. In addition, this study investigates the effect of MWCNT functionalization on the dielectric elastomeric actuation. The compliant electrodes using the MWCNT functionalized with (-COOH) group was also found to have a lower electrical conductivity and areal actuation strain, in comparison to the ones using the pristine MWCNT filler. In addition to binder, solvent for dispersing MWCNT-COOH was found to affect the actuation strain even though the solvent is eventually removed by

  17. Study of lithium glassy solid electrolyte/electrode interface by ...

    Indian Academy of Sciences (India)

    Cells of lithium ion conducting glassy electrolyte Li2SO4–Li2O–B2O3 with different combinations of electrodes (stainless steel blocking electrode, lithium non-blocking electrode and TiS2 electrode) have been prepared. The a.c. impedance measurements of the cells have been studied at elevated temperature as a function ...

  18. Production of Manual Metal Arc Welding Electrodes with Local Raw ...

    African Journals Online (AJOL)

    Manual arc welding using flux coated electrodes is carried out by producing an electric arc between the base metal and a flux covered metal electrode with electric current that depends on the type of electrode, material, welding position and the desired strength. The composition of flux coated electrodes is complex and a ...

  19. production of manual arc welding electrodes with local raw materials

    African Journals Online (AJOL)

    CHUKSSUCCESS 4 LOVE

    ABSTRACT. Manual arc welding using flux coated electrodes is carried out by producing an electric arc between the base metal and a flux covered metal electrode with electric current that depends on the type of electrode, material, welding position and the desired strength. The composition of flux coated electrodes is ...

  20. Exploring the electrodes alignment and mushrooming effects on ...

    Indian Academy of Sciences (India)

    The upper electrode lever has moved towards the lower electrode and squeezed the based metals that placed in between (Rao et al 2009). The welding current was released immediately after the squeezing cycles of pneumatic based electrode actuation is achieved. Thereafter the electrode pressing mechanism has ...

  1. Impulse breakdown of small air gap in electric field Part I: Influence ...

    African Journals Online (AJOL)

    The influence of barrier position on breakdown voltage in air dielectric has been investigated. Needle and Cone positive point electrodes were used and the effects of electrode curvature on barrier position for maximum breakdown voltage were compared, with air gap for the point to plane electrode fixed at 10 cm for all the ...

  2. Post-test examination of a copper electrode from deposition hole 5 in the Prototype Repository

    International Nuclear Information System (INIS)

    Rosborg, Bo

    2013-04-01

    can have a marked influence on the corrosion behaviour between the exposed small samples and the big components exist. The most convincing is that lubricants were used in manufacturing of the full-size bentonite blocks and rings (so available machines could handle the required pressure); lubricants have neither been used for the copper electrodes in the Prototype Repository, nor for the copper coupons in the LOT test parcels. Based upon the performed corrosion potential measurements and the findings from the post-test examination the following scenario of exposure is envisaged: When installed the copper electrode had merely a very thin cuprite film on the surface from exposure in air. After some length of exposure a corrosion potential was reached that allowed formation of Cu(II) corrosion products. Since the chloride activity in the pore water from start of exposure was low (the bentonite had been conditioned with tap water), malachite rather than paratacamite was formed. Later on the corrosion potential has decreased, influenced by changes in the near-field environment and filming of the surface, and obtained a corrosion potential of -40 mV SHE at the time when part of the concrete plug to the outer section had been removed, which indicates a mildly oxidizing environment. Thus, it is anticipated that the copper electrode has been exposed to oxic conditions all through the exposure period

  3. Post-test examination of a copper electrode from deposition hole 5 in the Prototype Repository

    Energy Technology Data Exchange (ETDEWEB)

    Rosborg, Bo [Rosborg Consulting, Nykoeping (Sweden)

    2013-04-15

    bentonite. Differences that can have a marked influence on the corrosion behaviour between the exposed small samples and the big components exist. The most convincing is that lubricants were used in manufacturing of the full-size bentonite blocks and rings (so available machines could handle the required pressure); lubricants have neither been used for the copper electrodes in the Prototype Repository, nor for the copper coupons in the LOT test parcels. Based upon the performed corrosion potential measurements and the findings from the post-test examination the following scenario of exposure is envisaged: When installed the copper electrode had merely a very thin cuprite film on the surface from exposure in air. After some length of exposure a corrosion potential was reached that allowed formation of Cu(II) corrosion products. Since the chloride activity in the pore water from start of exposure was low (the bentonite had been conditioned with tap water), malachite rather than paratacamite was formed. Later on the corrosion potential has decreased, influenced by changes in the near-field environment and filming of the surface, and obtained a corrosion potential of -40 mV SHE at the time when part of the concrete plug to the outer section had been removed, which indicates a mildly oxidizing environment. Thus, it is anticipated that the copper electrode has been exposed to oxic conditions all through the exposure period.

  4. Enhancement of dielectrophoresis using fractal gold nanostructured electrodes.

    Science.gov (United States)

    Koklu, Anil; Sabuncu, Ahmet C; Beskok, Ali

    2017-06-01

    Dielectrophoretic motions of Saccharomyces cerevisiae (yeast) cells and colloidal gold are investigated using electrochemically modified electrodes exhibiting fractal topology. Electrodeposition of gold on electrodes generated repeated patterns with a fern-leaf type self-similarity. A particle tracking algorithm is used to extract dielectrophoretic particle velocities using fractal and planar electrodes in two different medium conductivities. The results show increased dielectrophoretic force when using fractal electrodes. Strong negative dielectrophoresis of yeast cells in high-conductivity media (1.5 S/m) is observed using fractal electrodes, while no significant motion is present using planar electrodes. Electrical impedance at the electrode/electrolyte interface is measured using impedance spectroscopy technique. Stronger electrode polarization (EP) effects are reported for planar electrodes. Decreased EP in fractal electrodes is considered as a reason for enhanced dielectrophoretic response. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Monitoring drilling mud composition using flowing liquid junction electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Jasinski, R.; Fletcher, P.; Vercaemer, C.

    1990-06-27

    The concentration of a chosen ionic component of a drilling mud is determined from the potential difference between an ion selective electrode, selective to the component and a reference electrode, the reference electrode being connected to the mud by a liquid junction through which reference electrolyte flows from the electrode to the mud. The system avoids errors due to undesirable interactions between the mud and the reference electrode materials. (author).

  6. Optimising carbon electrode materials for adsorptive stripping voltammetry

    OpenAIRE

    Chaisiwamongkhol, K; Batchelor-McAuley, C; Sokolov, S; Holter, J; Young, N; Compton, R

    2017-01-01

    Different types of carbon electrode materials for adsorptive stripping voltammetry are studied through the use of cyclic voltammetry. Capsaicin is utilised as a model compound for adsorptive stripping voltammetry using unmodified and modified basal plane pyrolytic graphite (BPPG) electrodes modified with multi-walled carbon nanotubes, carbon black or graphene nanoplatelets, screen printed carbon electrodes (SPE), carbon nanotube modified screen printed electrodes, and carbon paste electrodes....

  7. Studying the thermal performance of a bipolar radiofrequency ablation with an improved electrode matrix system: In vitro experiments and modelling

    International Nuclear Information System (INIS)

    Shao, Y.L.; Leo, H.L.; Chua, K.J.

    2017-01-01

    Highlights: • We made judicious modification to the Penne’s equation in the process of developing our model. We consider the liver to consist of tumor and health tissue. The model has been validated with experimental data. • The proposed electrode system can reduce the tissue volume damage outside the electrodes. The designed building unit with 10 mm inter-electrode distance is the optimal choice to achieve desired ablation zone. • The influence of blood vessel is relatively small for using this electrode system. A spatial distance of 13 mm is deemed as the safe distance between the wall of the central probe and the large vessel. • This proposed electrode system demonstrated higher ablation stability even for tissue regions that are close to blood vessels. The system is better suited for matrix-type RFA. - Abstract: Radiofrequency ablation (RFA) is becoming an effective treatment method for both primary tumors and tumors that have metastasized. Large tumors in difficult anatomic locations can be treated by RFA technologies. However, constant size and regular shape of damage zones cannot be obtained by recent RFA technologies. The aim of this study is to optimize the stability of RFA treatment by employing a newly proposed bipolar electrode system. A hepatic RFA mathematical model is developed by the finite element method approach. The model is validated with the experimental data. This model is then used to verify the reliability and stability of the proposed electrode system. Simulated results showed the cross section of the ablation zone utilizing designed electrode system approximates a square. In addition, the fraction of the necrosed tissue with this electrode pattern turned out to be larger than the fraction with single-probe RFA techniques. This system demonstrated higher ablation stability even for tissue regions that are close to blood vessels. The proposed electrode system is better suited for matrix-type RFA.

  8. The progress of nanocrystalline hydride electrode materials

    International Nuclear Information System (INIS)

    Jurczyk, M.

    2004-01-01

    This paper reviews research at the Institute of Materials Science and Engineering, Poznan University of Technology, on the synthesis of nanocrystalline hydride electrode materials. Nanocrystalline materials have been synthesized by mechanical alloying (MA) followed by annealing. Examples of the materials include TiFe - , ZrV 2- , LaNi 5 and Mg 2 Ni-type phases. Details on the process used and the enhancement of properties due to the nanoscale structures are presented. The synthesized alloys were used as negative electrode materials for Ni-MH battery. The properties of hydrogen host materials can be modified substantially by alloying to obtain the desired storage characteristics. For example, it was found that the respective replacement of Fe in TiFe by Ni and/or by Cr, Co, Mo improved not only the discharge capacity but also the cycle life of these electrodes. The hydrogen storage properties of nanocrystalline ZrV 2 - and LaNi 5 -type powders prepared by mechanical alloying and annealing show no big difference with those of melt casting (polycrystalline) alloys. On the other hand, a partial substitution of Mg by Mn or Al in Mg 2 Ni alloy leads to an increase in discharge capacity, at room temperature. Furthermore, the effect of the nickel and graphite coating on the structure of some nanocrystalline alloys and the electrodes characteristics were investigated. In the case of Mg 2 Ni-type alloy mechanical coating with graphite effectively reduced the degradation rate of the studied electrode materials. The combination of a nanocrystalline TiFe - , ZrV 2 - and LaNi 5 -type hydride electrodes and a nickel positive electrode to form a Ni-MH battery, has been successful. (authors)

  9. Carbon coated stainless steel as counter electrode for dye sensitized solar cells

    Science.gov (United States)

    Prakash, Shejale Kiran; Sharma, Rakesh K.; Roy, Mahesh S.; Kumar, Mahesh

    2014-10-01

    A new type of counter electrode for dye sensitized solar cells has been fabricated using a stainless steel sheet as substrate and graphite, graphene and multiwall carbon nanotubes as the catalytic material which applied by screen printing technique. The sheet resistances of the substrates and there influence on the dye sensitized solar cells has been studied. The fabricated counter electrodes i.e. SS-graphite, SS-graphene SS-MWCNT and SS-platinum were tested for their photovoltaic response in the form of dye sensitized solar cells.

  10. Amperometric titration of thorium and some lanthanoids in acetic-acid medium using two indicator electrodes

    International Nuclear Information System (INIS)

    Khadeev, V.A.; Gevorgyan, A.M.; Talipov, Sh.T.; Kostylev, V.S.

    1979-01-01

    The votammetric behaviour of nitriletrimethylphosphonic acid (NTMP) in the medium of anhydrous acetic acid with different backgrounds in the anode region of polarization of a platinum microdisk electrode, is studied. The optimal conditions are found for the amperometric titration with two indicator electrodes of thorium and same lanthanides by a NTMP solution in anhydrous acetic medium. The influence of foreign anions and cations on the results of titration by the NTPM solution in anhydrous acetic acid is studied. The selectivity of titration in anhydrous medium is higher than in aqueous

  11. A novel rotating disk electrode cell design; The inverted rotating disk electrode

    Energy Technology Data Exchange (ETDEWEB)

    Zdunek, A.D.; Selman, J.R. (Illinois Inst. of Tech., Chicago, IL (United States). Dept. of Chemical Engineering)

    1992-09-01

    In this paper a new cell configuration for use with the rotating disk electrode (RDE), the inverted rotating disk electrode (IRDE), is outlined. The IRDE faces upwards in solution and rotates without electrolyte leakage, even in highly corrosive solutions. This facilitates gas evolution and free convection studies. Mass transfer characteristics obtained by limiting current measurements agree well with literature for the RDE.

  12. Rare Earth Element Fluorocarbonate Minerals from the Olympic Dam Cu-U-Au-Ag Deposit, South Australia

    Directory of Open Access Journals (Sweden)

    Danielle S. Schmandt

    2017-10-01

    Full Text Available Olympic Dam is a world-class breccia-hosted iron-oxide copper-gold-uranium ore deposit located in the Gawler Craton, South Australia. It contains elevated concentrations of rare earth elements (REE which occur as the REE minerals bastnäsite, synchysite, florencite, monazite, and xenotime. This is the first study to focus on the mineralogy and composition of the most abundant REE mineral at Olympic Dam, bastnäsite, and subordinate synchysite. The sample suite extends across the deposit and represents different sulfide mineralization styles (chalcopyrite-bornite and bornite-chalcocite and breccias of various types, ranging from those dominated by clasts of granite, dykes, and hematite. The REE-fluorocarbonates (bastnäsite and synchysite typically occur as fine-grained (<50 μm disseminations in Cu-Fe-sulfides and gangue minerals, and also within breccia matrix. They are also locally concentrated within macroscopic REE-mineral-rich pockets at various locations across the deposit. Such coarse-grained samples formed the primary target of this study. Three general textural groups of bastnäsite are recognized: matrix (further divided into disseminated, fine-grained, and stubby types, irregular (sulfide-associated, and clast replacement. Textures are largely driven by the specific location and prevailing mineral assemblage, with morphology and grain size often controlled by the associated minerals (hematite, sulfides. Major element concentration data reveal limited compositional variation among the REE-fluorocarbonates; all are Ce-dominant. Subtle compositional differences among REE-fluorocarbonates define a spectrum from relatively La-enriched to (Ce + Nd-enriched phases. Granite-derived hydrothermal fluids were the likely source of F in the REE-fluorocarbonates, as well as some of the CO2, which may also have been contributed by associated mafic-ultramafic magmatism. However, transport of REE by Cl-ligands is the most likely scenario. Stubby bastnäsite and synchysite may have formed earlier, coincident with hydrothermal alteration of granite releasing Ca from feldspars. Other categories of bastnäsite, notably those co-existing with sulfides, and reaching the top of the IOCG mineralization at Olympic Dam (chalcocite + bornite zone are relatively younger. Such an interpretation is concordant with subtle changes in the REE patterns for the different categories. The common association of bastnäsite and fluorite throughout the deposit is typical of the hematite breccias and can be deposited from neutral, slightly acidic fluids (sericite stability at T ≈ 300 °C.

  13. Integrate metalogenic database with GIS geological project (deposite Au-Ag Far East Russia). WEB-GIS approach.

    Science.gov (United States)

    Kucharenko, Evgeniy; Asavin, Alex

    2015-04-01

    Resource depletion has forced us to search for new ore deposit and reanalyze old mineral deposits. This is the main aim of metallogenic studies. Synthesis information about features resources work out deposit and emerging fields will play a key role in future. Development of metallogeny databases is one of the most difficult tasks for Earth sciences. Database needs to enter a large number of parameters describing the object of study - mine or ore occurrence. Majority of these parameters belong to different areas of geological knowledge. It can be ore mineralogy, geochemistry, lithology of host rocks, tectonic characteristics ore-controlling structures, geochemical parameters of ore processes, geochronological data on age of geological formations and processes of ore formation and some others. However, the cartographic materials of various scales apart from diverse documentation and numerical information are of a great importance. The adopted framework for the analysis of large-scale metallogeny has several levels: 1. The ore body (usually 1: 50000, 1: 100000) 2. The ore field, the field (1: 200000) 3. The ore cluster (1: 500000) Researchers can vary scheme and scale values, but fundamentally three levels of scale describing the location and geological structures controlling the placement of ore are included at least. Attention should be pay to the system of description the ore deposit. It is necessary to create the universal scheme for development of metallogeny information systems and set up the universal algorithm of ore deposit description. There is its own order of importance of used features and a form of description for each type of deposits and ore and genetic group and ore element. Lack of definition in the classification of a particular metallogenic object makes the choice of algorithm description justified quite weakly. It is quite notable that available features which used for description of different deposit (even of the same genetic group) are not of the same type or detailed enough. Waste deposit usually takes as a reference object with the most complete description in opposite to the recently discovered deposit not enough studied and with quite limited list of information indicators. There are following most actual tasks for information metallogeny system: 1. Search summarizing the characteristics of different objects 2. Select the most informative group of features 3. Show the links of groups of signs and analyze it as far as genesis of deposits. The actual task's list could be continued but it is enough to start. Essentially mentioned problems put us in a situation when deposit's metallogenic database is not available. There is only limited number of typical databases (for certain types of minerals) characterized nothing more than name of the fields and basic indicators of its economic importance (stocks, component content, ore types). The additional information: the age of host rock or ores or geochemistry features of some geological objects uses quite rarely. There is no systematic data for all objects in the database. Database of carbonatite deposits is the most well-developed. It should be also mentioned some works [Woolley & Kjarsgaard 2009; Bagdasarov et al.,2001; Burmistrov et al., 2008]. Unfortunately, such important characteristics as geological maps are not included there as

  14. [The forming phase and various properties of Au, Ag, Cu and Ga mixture in metal fired crowns].

    Science.gov (United States)

    Yoshida, T; Miyasaka, T; Okamura, H; Mizutani, Y; Hanaka, M; Miyake, S; Seo, I; Ito, M

    1990-11-01

    A new time-saving method has been developed to produce artificial crowns without using the casting process. Plastic mixtures of gallium and other metal particles are kneaded into desired shape and then heated for hardening. By this method, the time required for hardening and producing restorative materials has been shortened greatly. In the present experiment, gallium was triturated with powdered gold, silver and copper to make binary alloy samples. The dimensional change was measured between heat treatment. After heat treatment, the test piece was examined for compressive strength, compressive shrinkage, hardness, tarnishing and difference in phase. Non-heated and heated alloy specimens (Au-Ga, Ag-Ga, Cu-Ga) expanded to form the new phase. The ability of Au-Ga samples to bear compressive strength, when heated at 300 degrees C or more (AuGa2----AuGa), became 2.6 times greater than that of non-heat-treated specimens. The compressive strength of Ag-Ga samples dropped briefly at 350 degrees C (Ag0.72Ga0.28----Ag3Ga) but increased at 450 degrees C (Ag3Ga----AgGa). The strength of Cu-Ga pieces fell by half at 475 degrees C and upward (CuGa2----unknown phase). A compression test showed that the contraction percentage of Au and Ag specimens became large as a result of heat treatment, while that of Cu alloys remained almost unchanged. The results of a hardness test (HV) were comparable to those of the compressive strength test. The Au-Ga alloys increased in hardness after high-temperature treatment. In the Ag-Ga alloys, hardness declined at 350 degrees C and increased at 450 degrees C. There was no difference in hardness between Cu specimens after heat treatment and those allowed to stand at room temperature. A tarnishing test revealed that Au-Ga samples turned slightly yellowish. In the case of Ag-Ga samples, the reflectivity Y (%) dipped slightly but discoloration was not recognizable. However, the Cu-Ga samples which were heated at temperatures of up to 280 degrees C showed a slight drop in reflectivity, but those heated at temperatures higher than 280 degrees C decreased to 50-66% in reflectivity and turned black.

  15. El yacimiento volcanogénico de Cu-Zn-Pb (Au + Ag el cobre: inclusiones fluidas

    Directory of Open Access Journals (Sweden)

    Joan C. Melgarejo

    2001-03-01

    Full Text Available El depósito El Cobre se localiza al NO de Santiago de Cuba y encaja en la Secuencia Media del Grupo El Cobre, en el arco del Paleógeno. Se estudiaron inclusiones fluidas primarias y pseudosecundarias en cristales de cuarzo, anhidrita, esfarelita y calcita, correspondientes a los principales tipos de mineralización: stockwork silíceo, filones silíceos, filones anhídritico-epidóticos y mineralizaciones estratiforme de barita. Las inclusiones se clasificaron en bifásicas L-V, que presentan tamaño entre 5 y 40 micras, y el grado de relleno es de 0,7 a 0,8. Se obtuvieron temperaturas de fusión del hielo entre -1,1 y -6,7ºC, y les correspondieron salinidades entre 1,9 y 10,1 % en peso de NaCl eq., mientras que la temperatura de homogenización oscula entre 150 y 299ºC. durante los ensayos microtermométricos no se observó la formación de clatratos y las investigaciones mediante Raman no detectaron otros gases en la fase vapor, lo que indica un componente mayoritario de vapor de agua. La homogenización a líquido de las inclusiones con promedio entre 165 y 281ºC, y su grado de relleno uniforme, sugieren que no ocurrió le ebullición durante la deposición de estas mineralizaciones. Estos valores promedios de temperatura mencionados, así como los valores promedios de salinidad entre 2,3 y 5,7 % en peso de NaCl eq. están dentro del rago de salinidad y temperatura reportado en numerosos depósitos VMS, como los tipo Kuroko

  16. Energy Reflection Coefficients for 5-10 keV He Ions Incident on Au, Ag, and Cu

    DEFF Research Database (Denmark)

    Schou, Jørgen; Sørensen, H.; Littmark, U.

    1978-01-01

    The calorimetric deuterium-film method was used for measurements of the energy reflection coefficient γ for normal incidence of 5-10 keV He ions on Cu, Ag and Au. A theoretical calculation of γ by means of transport theory gives fair agreement with the experimental results. The experimental data...... the experimental and theoretical results for the He ions are in acceptable agreement with other experimental and theoretical results. For He ions, the experimental γ-values are 20-30% above the values for hydrogen ions for the same value of ε...

  17. Eco-friendly synthesis of gelatin-capped bimetallic Au-Ag nanoparticles for chemiluminescence detection of anticancer raloxifene hydrochloride.

    Science.gov (United States)

    Alarfaj, Nawal A; El-Tohamy, Maha F

    2016-09-01

    This study described the utility of green analytical chemistry in the synthesis of gelatin-capped silver, gold and bimetallic gold-silver nanoparticles (NPs). The preparation of nanoparticles was based on the reaction of silver nitrate or chlorauric acid with a 1.0 wt% aqueous gelatin solution at 50°C. The gelatin-capped silver, gold and bimetallic NPs were characterized using transmission electron microscopy, UV-vis, X-ray diffraction and Fourier transform infrared spectroscopy, and were used to enhance a sensitive sequential injection chemiluminescence luminol-potassium ferricyanide system for determination of the anticancer drug raloxifene hydrochloride. The developed method is eco-friendly and sensitive for chemiluminescence detection of the selected drug in its bulk powder, pharmaceutical injections and biosamples. After optimizing the conditions, a linear relationship in the range of 1.0 × 10(-9) to 1.0 × 10(-1)  mol/L was obtained with a limit of detection of 5.0 × 10(-10)  mol/L and a limit of quantification of 1.0 × 10(-9)  mol/L. Statistical treatment and method validation were performed based on ICH guidelines. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  18. Colloidal paradigm in supercapattery electrode systems

    Science.gov (United States)

    Chen, Kunfeng; Xue, Dongfeng

    2018-01-01

    Among decades of development, electrochemical energy storage systems are now sorely in need of a new design paradigm at the nano size and ion level to satisfy the higher energy and power demands. In this review paper, we introduce a new colloidal electrode paradigm for supercapattery that integrates multiple-scale forms of matter, i.e. ion clusters, colloidal ions, and nanosized materials, into one colloid system, coupled with multiple interactions, i.e. electrostatic, van der Waals forces, and chemical bonding, thus leading to the formation of many redox reactive centers. This colloidal electrode not only keeps the original ionic nature in colloidal materials, but also creates a new attribute of high electroactivity. Colloidal supercapattery is a perfect application example of the novel colloidal electrode, leading to higher specific capacitance than traditional electrode materials. The high electroactivity of the colloidal electrode mainly comes from the contribution of exposed reactive centers, owing to the confinement effect of carbon and a binder matrix. Systematic and thorough research on the colloidal system will significantly promote the development of fundamental science and the progress of advanced energy storage technology.

  19. FINAL REPORT: Transformational electrode drying process

    Energy Technology Data Exchange (ETDEWEB)

    Claus Daniel, C.; Wixom, M.(A123 Systems, Inc.)

    2013-12-19

    This report includes major findings and outlook from the transformational electrode drying project performance period from January 6, 2012 to August 1, 2012. Electrode drying before cell assembly is an operational bottleneck in battery manufacturing due to long drying times and batch processing. Water taken up during shipment and other manufacturing steps needs to be removed before final battery assembly. Conventional vacuum ovens are limited in drying speed due to a temperature threshold needed to avoid damaging polymer components in the composite electrode. Roll to roll operation and alternative treatments can increase the water desorption and removal rate without overheating and damaging other components in the composite electrode, thus considerably reducing drying time and energy use. The objective of this project was the development of an electrode drying procedure, and the demonstration of processes with no decrease in battery performance. The benchmark for all drying data was an 80°C vacuum furnace treatment with a residence time of 18 – 22 hours. This report demonstrates an alternative roll to roll drying process with a 500-fold improvement in drying time down to 2 minutes and consumption of only 30% of the energy compared to vacuum furnace treatment.

  20. Nanowire Electrodes for Advanced Lithium Batteries

    International Nuclear Information System (INIS)

    Huang, Lei; Wei, Qiulong; Sun, Ruimin; Mai, Liqiang

    2014-01-01

    Since the commercialization of lithium ion batteries (LIBs) in the past two decades, rechargeable LIBs have become widespread power sources for portable devices used in daily life. However, current demands require higher energy density and power density of batteries. The electrochemical energy storage performance of LIBs could be improved by applying nanomaterial electrodes, but their fast capacity fading is still one of the key limitations and the mechanism need to be clearly understood. Single nanowire electrode devices are considered as a versatile platform for in situ probing the direct relationship between electrical transport, structure change, and other properties of the single nanowire electrode along with the charge/discharge process. The results indicate that the conductivity decrease of the nanowire electrode and the structural disorder/destruction during electrochemical reaction limit the cycling performance of LIBs. Based on the in situ observations, some feasible optimization strategies, including prelithiation, coaxial structure, nanowire arrays, and hierarchical structure architecture, are proposed and utilized to restrain the conductivity decrease and structural disorder/destruction. Further, the applications of nanowire electrodes in some “beyond Li-ion” batteries, such as Li-S and Li-air batteries are also described.

  1. Bioinspired fractal electrodes for solar energy storages.

    Science.gov (United States)

    Thekkekara, Litty V; Gu, Min

    2017-03-31

    Solar energy storage is an emerging technology which can promote the solar energy as the primary source of electricity. Recent development of laser scribed graphene electrodes exhibiting a high electrical conductivity have enabled a green technology platform for supercapacitor-based energy storage, resulting in cost-effective, environment-friendly features, and consequent readiness for on-chip integration. Due to the limitation of the ion-accessible active porous surface area, the energy densities of these supercapacitors are restricted below ~3 × 10 -3  Whcm -3 . In this paper, we demonstrate a new design of biomimetic laser scribed graphene electrodes for solar energy storage, which embraces the structure of Fern leaves characterized by the geometric family of space filling curves of fractals. This new conceptual design removes the limit of the conventional planar supercapacitors by significantly increasing the ratio of active surface area to volume of the new electrodes and reducing the electrolyte ionic path. The attained energy density is thus significantly increased to ~10 -1  Whcm -3 - more than 30 times higher than that achievable by the planar electrodes with ~95% coulombic efficiency of the solar energy storage. The energy storages with these novel electrodes open the prospects of efficient self-powered and solar-powered wearable, flexible and portable applications.

  2. Bioinspired fractal electrodes for solar energy storages

    Science.gov (United States)

    Thekkekara, Litty V.; Gu, Min

    2017-03-01

    Solar energy storage is an emerging technology which can promote the solar energy as the primary source of electricity. Recent development of laser scribed graphene electrodes exhibiting a high electrical conductivity have enabled a green technology platform for supercapacitor-based energy storage, resulting in cost-effective, environment-friendly features, and consequent readiness for on-chip integration. Due to the limitation of the ion-accessible active porous surface area, the energy densities of these supercapacitors are restricted below ~3 × 10-3 Whcm-3. In this paper, we demonstrate a new design of biomimetic laser scribed graphene electrodes for solar energy storage, which embraces the structure of Fern leaves characterized by the geometric family of space filling curves of fractals. This new conceptual design removes the limit of the conventional planar supercapacitors by significantly increasing the ratio of active surface area to volume of the new electrodes and reducing the electrolyte ionic path. The attained energy density is thus significantly increased to ~10-1 Whcm-3- more than 30 times higher than that achievable by the planar electrodes with ~95% coulombic efficiency of the solar energy storage. The energy storages with these novel electrodes open the prospects of efficient self-powered and solar-powered wearable, flexible and portable applications.

  3. Microfabricated Reference Electrodes and their Biosensing Applications

    Directory of Open Access Journals (Sweden)

    M. Jamal Deen

    2010-03-01

    Full Text Available Over the past two decades, there has been an increasing trend towards miniaturization of both biological and chemical sensors and their integration with miniaturized sample pre-processing and analysis systems. These miniaturized lab-on-chip devices have several functional advantages including low cost, their ability to analyze smaller samples, faster analysis time, suitability for automation, and increased reliability and repeatability. Electrical based sensing methods that transduce biological or chemical signals into the electrical domain are a dominant part of the lab-on-chip devices. A vital part of any electrochemical sensing system is the reference electrode, which is a probe that is capable of measuring the potential on the solution side of an electrochemical interface. Research on miniaturization of this crucial component and analysis of the parameters that affect its performance, stability and lifetime, is sparse. In this paper, we present the basic electrochemistry and thermodynamics of these reference electrodes and illustrate the uses of reference electrodes in electrochemical and biological measurements. Different electrochemical systems that are used as reference electrodes will be presented, and an overview of some contemporary advances in electrode miniaturization and their performance will be provided.

  4. An active electrode for biopotential recording from small localized bio-sources

    Directory of Open Access Journals (Sweden)

    Pallikarakis Nicolas E

    2004-07-01

    forearm. The peak-to-peak noise voltage measured at the amplifier output, with input terminals connected to common, was 10 mVp-p, or 2 μVp-p referred to the input. The common-mode rejection ratio of the amplifier was 96 dB at 50 Hz, measured with imbalanced electrodes' impedances. The prototype was also tested practically and sample records were obtained after a low intensity SLB laser stimulation. All measurements showed almost a complete absence of 50 Hz interference, although no electrolyte gel or skin preparation was applied. Conclusion The results showed that the new active electrode presented significantly reduced the electrode-skin impedance, its variation and motion artifact influences. This allowed SLB signals with relatively high quality to be recorded without skin preparation. The design offers low noise and major reduction in parts, size and power consumption. The active electrode specifications were found to be better or at least comparable to those of other existing designs.

  5. Textile electrodes as substrates for the electrodeposition of porous ZnO.

    Science.gov (United States)

    Loewenstein, Thomas; Hastall, Andreas; Mingebach, Markus; Zimmermann, Yvonne; Neudeck, Andreas; Schlettwein, Derck

    2008-04-14

    Metal-coated polyamide threads and filaments were chosen as substrate electrodes to deposit highly porous ZnO films for photovoltaic application. The films were electrodeposited at 70 degrees C from oxygen-saturated aqueous zinc salt solutions containing EosinY as a structure directing agent. The current density during deposition was increased compared with planar electrodes by enhanced diffusion at the filaments operating as cylindrical microelectrodes. Analysis by scanning electron microscopy showed an influence of geometrical constraints within the textiles and the hydrodynamic flow rate in the deposition solution on the film morphology. Photoelectrochemical characterization of sensitized films revealed the feasibility of the presented approach and indicated further steps needed for electrode optimization.

  6. A canonical correlation analysis based EMG classification algorithm for eliminating electrode shift effect.

    Science.gov (United States)

    Zhe Fan; Zhong Wang; Guanglin Li; Ruomei Wang

    2016-08-01

    Motion classification system based on surface Electromyography (sEMG) pattern recognition has achieved good results in experimental condition. But it is still a challenge for clinical implement and practical application. Many factors contribute to the difficulty of clinical use of the EMG based dexterous control. The most obvious and important is the noise in the EMG signal caused by electrode shift, muscle fatigue, motion artifact, inherent instability of signal and biological signals such as Electrocardiogram. In this paper, a novel method based on Canonical Correlation Analysis (CCA) was developed to eliminate the reduction of classification accuracy caused by electrode shift. The average classification accuracy of our method were above 95% for the healthy subjects. In the process, we validated the influence of electrode shift on motion classification accuracy and discovered the strong correlation with correlation coefficient of >0.9 between shift position data and normal position data.

  7. Determination of Nitrite in Meat Products using a Metalloporphyrin Based Nitrite-Selective Membrane Electrode

    Directory of Open Access Journals (Sweden)

    Dana VLASCICI

    2006-07-01

    Full Text Available The potentiometric response characteristics of a nitrite-selective electrode based on Co (III tetraphenylporphyrins (TPP in o-nitrophenyloctylether plasticized polyvinyl chloride membranes are compared. To establish the optimum composition of the membrane, different molar percents of cationic derivative (0-100 mol% relative to ionophore were used. The influence of different plasticizers: o-nitrophenyloctylether, dioctylphtalate and tricresilphosphate on potentiometric answer were studied. Electrodes formulated with membranes containing 1 wt% ClCoTPP, 66 wt% o-NPOE, 33 wt% PVC (plasticizer:PVC = 2:1 and the lipophilic cationic derivative (10 mol% are shown to exhibit high selectivity for nitrite over many anions, except the lipophilic anions perchlorate and thiocyanate. The electrodes based on Co (III porphyrins were used for the potentiometric determination of nitrites in meat products. The results were compared with a colorimetric method used as the reference method. There was a good agreement between the potentiometric and colorimetric procedures.

  8. Effects of electrode material and configuration on the characteristics of planar resistive switching devices

    KAUST Repository

    Peng, H.Y.

    2013-11-13

    We report that electrode engineering, particularly tailoring the metal work function, measurement configuration and geometric shape, has significant effects on the bipolar resistive switching (RS) in lateral memory devices based on self-doped SrTiO3 (STO) single crystals. Metals with different work functions (Ti and Pt) and their combinations are used to control the junction transport (either ohmic or Schottky-like). We find that the electric bias is effective in manipulating the concentration of oxygen vacancies at the metal/STO interface, influencing the RS characteristics. Furthermore, we show that the geometric shapes of electrodes (e.g., rectangular, circular, or triangular) affect the electric field distribution at the metal/oxide interface, thus plays an important role in RS. These systematic results suggest that electrode engineering should be deemed as a powerful approach toward controlling and improving the characteristics of RS memories. 2013 Author(s).

  9. A reference electrode based on polyvinyl butyral (PVB) polymer for decentralized chemical measurements

    International Nuclear Information System (INIS)

    Guinovart, Tomàs; Crespo, Gastón A.; Rius, F. Xavier; Andrade, Francisco J.

    2014-01-01

    Highlights: • A disposable solid-contact reference electrode for potentiometry is presented. • The device shows unsensitivity to most ions, redox potential and light. • Low-cost and good stability, ideal to build disposable potentiometric sensors. • Nanopores formed in the membrane control the flux of ions with the solution. - Abstract: A new solid-state reference electrode using a polymeric membrane of polyvinyl butyral (PVB), Ag/AgCl and NaCl to be used in decentralized chemical measurements is presented. The electrode is made by drop-casting the membrane cocktail onto a glassy carbon (GC) substrate. A stable potential (less than 1 mV dec −1 ) over a wide range of concentrations for the several chemical species tested is obtained. No significant influence to changes in redox potential, light and pH are observed. The response of this novel electrode shows good correlation when compared with a conventional double-junction reference electrode. Also good long-term stability (90 ± 33 μV/h) and a lifetime of approximately 4 months are obtained. Aspects related to the working mechanisms are discussed. Atomic Force Microscopy (AFM) studies reveal the presence of nanopores and channels on the surface, and electrochemical impedance spectroscopy (EIS) of optimized electrodes show low bulk resistances, usually in the kΩ range, suggesting that a nanoporous polymeric structure is formed in the interface with the solution. Future applications of this electrode as a disposable device for decentralized measurements are discussed. Examples of the utilization on wearable substrates (tattoos, fabrics, etc) are provided

  10. A reference electrode based on polyvinyl butyral (PVB) polymer for decentralized chemical measurements

    Energy Technology Data Exchange (ETDEWEB)

    Guinovart, Tomàs [Departament de Química Orgànica i Química Analítica, Universitat Rovira i Virgili, Carrer Marcellí Domingo s/n 43007 Tarragona (Spain); Crespo, Gastón A. [Department of Inorganic and Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211 Geneva (Switzerland); Rius, F. Xavier [Departament de Química Orgànica i Química Analítica, Universitat Rovira i Virgili, Carrer Marcellí Domingo s/n 43007 Tarragona (Spain); Andrade, Francisco J., E-mail: franciscojavier.andrade@urv.cat [Departament de Química Orgànica i Química Analítica, Universitat Rovira i Virgili, Carrer Marcellí Domingo s/n 43007 Tarragona (Spain)

    2014-04-01

    Highlights: • A disposable solid-contact reference electrode for potentiometry is presented. • The device shows unsensitivity to most ions, redox potential and light. • Low-cost and good stability, ideal to build disposable potentiometric sensors. • Nanopores formed in the membrane control the flux of ions with the solution. Abstract: A new solid-state reference electrode using a polymeric membrane of polyvinyl butyral (PVB), Ag/AgCl and NaCl to be used in decentralized chemical measurements is presented. The electrode is made by drop-casting the membrane cocktail onto a glassy carbon (GC) substrate. A stable potential (less than 1 mV dec⁻¹ over a wide range of concentrations for the several chemical species tested is obtained. No significant influence to changes in redox potential, light and pH are observed. The response of this novel electrode shows good correlation when compared with a conventional double-junction reference electrode. Also good long-term stability (90 ± 33 μV/h) and a lifetime of approximately 4 months are obtained. Aspects related to the working mechanisms are discussed. Atomic Force Microscopy (AFM) studies reveal the presence of nanopores and channels on the surface, and electrochemical impedance spectroscopy (EIS) of optimized electrodes show low bulk resistances, usually in the kΩ range, suggesting that a nanoporous polymeric structure is formed in the interface with the solution. Future applications of this electrode as a disposable device for decentralized measurements are discussed. Examples of the utilization on wearable substrates (tattoos, fabrics, etc) are provided.

  11. Electrode erosion properties of gas spark switches for fast linear transformer drivers

    Science.gov (United States)

    Li, Xiaoang; Pei, Zhehao; Zhang, Yuzhao; Liu, Xuandong; Li, Yongdong; Zhang, Qiaogen

    2017-12-01

    Fast linear transformer drivers (FLTDs) are a popular and potential route for high-power devices employing multiple "bricks" in series and parallel, but they put extremely stringent demands on gas switches. Electrode erosion of FLTD gas switches is a restrictive and unavoidable factor that degrades performance and limits stability. In this paper, we systematically investigated the electrode erosion characteristics of a three-electrode field distortion gas switch under the typical working conditions of FLTD switches, and the discharge current was 7-46 kA with 46-300 ns rise time. A high speed frame camera and a spectrograph were used to capture the expansion process and the spectral emission of the spark channel was used to estimate the current density and the spark temperature, and then the energy fluxes and the external forces on the electrode surface were calculated. A tens of kilo-ampere nanosecond pulse could generate a 1011 W/m2 energy flux injection and 1.3-3.5 MPa external pressure on the electrode surface, resulting in a millimeter-sized erosion crater with the maximum peak height Rz reaching 100 μm magnitude. According to the morphological images by a laser scanning confocal microscope, the erosion crater of a FLTD switch contained three kinds of local morphologies, namely a center boiling region, an overflow region and a sputtering region. In addition, the crater size, the surface roughness, and the mass loss were highly dependent on the current amplitude and the transferred charge. We also observed Morphology Type I and Type II, respectively, with different pulse parameters, which had an obvious influence on surface roughness and mass loss. Finally, the quantitative relationship between the electrode mass loss and the pulse parameter was clarified. The transferred charge and the current amplitude were proved to be the main factors determining the electrode mass loss of a FLTD switch, and a least squares fitting expression for mass loss was also obtained.

  12. Electrode activation and passivation of solid oxide fuel cell electrodes

    DEFF Research Database (Denmark)

    Koch, Søren; Mogensen, Mogens Bjerg; Hendriksen, P.V.

    2006-01-01

    The performance of anode-supported cells with a composite LSM-YSZ cathode and an LSM current collector was investigated. Over the first 48 hours, after the application of a constant current, the cell voltage was observed to increase by up to 20%. When the current was switched off, the cell...... resistance increased significantly over the next four days at open circuit conditions. Apparently, at OCV conditions cell passivation occurs. The cell gradually reactivates, once the current is switched on again. Part of this activation/passivation process is fast enough to influence the resistance...... of the cell during i-V measurements (over less than 1 hour) and a considerable hysteresis is observed in the cell voltage during these measurements. Impedance spectroscopy was used to investigate the activation/passivation process. It was found that the series resistance and the part of the polarisation...

  13. Method for control of edge effects of oxidant electrode

    Science.gov (United States)

    Carr, Peter; Chi, Chen H.

    1980-12-23

    Described is an electrode assembly comprising; a. a porous electrode having a first and second exterior face with a cavity formed in the interior between said exterior faces thereby having first and second interior faces positioned opposite the first and second exterior faces; b. a counter electrode positioned facing each of the first and second exterior faces of the porous electrode; c. means for passing an oxidant through said porous electrode; and d. screening means for blocking the interior face of the porous electrode a greater amount than the blocking of the respective exterior face of the porous electrode, thereby maintaining a differential of oxidant electrode surface between the interior face and the exterior face. The electrode assembly is useful in a metal, halogen, halogen hydrate electrical energy storage device.

  14. Textile electrode straps for wrist-to-ankle bioimpedance measurements for Body Composition Analysis. Initial validation & experimental results.

    Science.gov (United States)

    Marquez, J C; Ferreira, J; Seoane, F; Buendia, R; Lindecrantz, K

    2010-01-01

    Electrical Bioimpedance (EBI) is one of the non-invasive monitoring technologies that could benefit from the emerging textile based measurement systems. If reliable and reproducible EBI measurements could be done with textile electrodes, that would facilitate the utilization of EBI-based personalized healthcare monitoring applications. In this work the performance of a custom-made dry-textile electrode prototype is tested. Four-electrodes ankle-to-wrist EBI measurements have been taken on healthy subjects with the Impedimed spectrometer SFB7 in the frequency range 5 kHz to 1 MHz. The EBI spectroscopy measurements taken with dry electrodes were analyzed via the Cole and Body Composition Analysis (BCA) parameters, which were compared with EBI measurements obtained with standard electrolytic electrodes. The analysis of the obtained results indicate that even when dry textile electrodes may be used for EBI spectroscopy measurements, the measurements present remarkable differences that influence in the Cole parameter estimation process and in the final production of the BCA parameters. These initial results indicate that more research work must be done to in order to obtain a textile-based electrode that ensures reliable and reproducible EBI spectroscopy measurements.

  15. Ion counting in supercapacitor electrodes using NMR spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, John M. [Department of Chemistry; University of Cambridge; Cambridge, UK; Forse, Alexander C. [Department of Chemistry; University of Cambridge; Cambridge, UK; Wang, Hao [Department of Chemistry; University of Cambridge; Cambridge, UK; Trease, Nicole M. [Department of Chemistry; Stony Brook University; New York, USA; Taberna, Pierre-Louis [Université Paul Sabatier Toulouse III; CIRIMAT; F-31062 Toulouse, France; Simon, Patrice [Université Paul Sabatier Toulouse III; CIRIMAT; F-31062 Toulouse, France; Grey, Clare P. [Department of Chemistry; University of Cambridge; Cambridge, UK; Department of Chemistry; Stony Brook University

    2014-01-01

    19F NMR spectroscopy has been used to study the local environments of anions in supercapacitor electrodes and to quantify changes in the populations of adsorbed species during charging. In the absence of an applied potential, anionic species adsorbed within carbon micropores (in-pore) are distinguished from those in large mesopores and spaces between particles (ex-pore) by a characteristic nucleus-independent chemical shift (NICS). Adsorption experiments and two-dimensional exchange experiments confirm that anions are in dynamic equilibrium between the in- and ex-pore environments with an exchange rate in the order of tens of Hz.19Fin situNMR spectra recorded at different charge states reveal changes in the intensity and NICS of the in-pore resonances, which are interpreted in term of changes in the population and local environments of the adsorbed anions that arise due to the charge-storage process. A comparison of the results obtained for a range of electrolytes reveals that several factors influence the charging mechanism. For a tetraethylammonium tetrafluoroborate electrolyte, positive polarisation of the electrode is found to proceed by anion adsorption at a low concentration, whereas increased ion exchange plays a more important role for a high concentration electrolyte. In contrast, negative polarization of the electrode proceeds by cation adsorption for both concentrations. For a tetrabutylammonium tetrafluoroborate electrolyte, anion expulsion is observed in the negative charging regime; this is attributed to the reduced mobility and/or access of the larger cations inside the pores, which forces the expulsion of anions in order to build up ionic charge. Significant anion expulsion is also observed in the negative charging regime for alkali metal bis(trifluoromethane)sulfonimide electrolytes, suggesting that more subtle factors also affect the charging mechanism.

  16. Insulated electrocardiographic electrodes. [without paste electrolyte

    Science.gov (United States)

    David, R. M.; Portnoy, W. A. (Inventor)

    1975-01-01

    An integrated system is disclosed including an insulated electrode and an impedance transformer which can be assembled in a small plastic housing and used for the acquisition of electrocardiographic data. The electrode may be employed without a paste electrolyte and may be attached to the body for extended usage without producing skin reaction. The electrode comprises a thin layer of suitable nontoxic dielectric material preferably deposited by radio frequency sputtering onto a conductive substrate. The impedance transformer preferably comprises an operational amplifier having an FET input stage connected in the unity gain configuration which provides a very low lower cut-off frequency, a high input impedance with a very small input bias current, a low output impedance, and a high signal-to-noise ratio.

  17. Hydrogen electrode reaction: A complete kinetic description

    International Nuclear Information System (INIS)

    Quaino, P.M.; Gennero de Chialvo, M.R.; Chialvo, A.C.

    2007-01-01

    The kinetic description of the hydrogen electrode reaction (HER) in the whole range of overpotentials (-0.2 < η (V) < 0.40) is presented. The Volmer-Heyrovsky-Tafel mechanism was solved considering simultaneously the following items: (i) the diffusional contribution of the molecular hydrogen from and towards the electrode surface, (ii) the forward and backward reaction rates of each elementary step and (iii) a Frumkin type adsorption for the reaction intermediate. In order to verify the descriptive capability of the kinetic expressions derived, an experimental study of the HER was carried out on a rotating platinum disc electrode in acid solution. From the correlation of these results the elementary kinetic parameters were evaluated and several aspects related to the kinetic mechanism were discussed. Finally, the use of these kinetic expressions to interpret results obtained on microelectrodes is also analysed

  18. Nanostructured electrodes for high-performance pseudocapacitors.

    Science.gov (United States)

    Lu, Qi; Chen, Jingguang G; Xiao, John Q

    2013-02-11

    The depletion of traditional energy resources as well as the desire to reduce high CO(2) emissions associated with energy production means that energy storage is now becoming more important than ever. New functional electrode materials are urgently needed for next-generation energy storage systems, such as supercapacitors or batteries, to meet the ever increasing demand for higher energy and power densities. Advances in nanotechnology are essential to meet those future challenges. It is critical to develop ways of synthesizing new nanomaterials with enhanced properties or combinations of properties to meet future challenges. In this Minireview we discuss several important recent studies in developing nanostructured pseudocapacitor electrodes, and summarize three major parameters that are the most important in determining the performance of electrode materials. A technique to optimize these parameters simultaneously and to achieve both high energy and power densities is also introduced. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Capacitor with a composite carbon foam electrode

    Science.gov (United States)

    Mayer, Steven T.; Pekala, Richard W.; Kaschmitter, James L.

    1999-01-01

    Carbon aerogels used as a binder for granularized materials, including other forms of carbon and metal additives, are cast onto carbon or metal fiber substrates to form composite carbon thin film sheets. The thin film sheets are utilized in electrochemical energy storage applications, such as electrochemical double layer capacitors (aerocapacitors), lithium based battery insertion electrodes, fuel cell electrodes, and electrocapacitive deionization electrodes. The composite carbon foam may be formed by prior known processes, but with the solid partides being added during the liquid phase of the process, i.e. prior to gelation. The other forms of carbon may include carbon microspheres, carbon powder, carbon aerogel powder or particles, graphite carbons. Metal and/or carbon fibers may be added for increased conductivity. The choice of materials and fibers will depend on the electrolyte used and the relative trade off of system resistivity and power to system energy.

  20. Washable and Reliable Textile Electrodes Embedded into Underwear Fabric for Electrocardiography (ECG Monitoring

    Directory of Open Access Journals (Sweden)

    Amale Ankhili

    2018-02-01

    Full Text Available A medical quality electrocardiogram (ECG signal is necessary for permanent monitoring, and an accurate heart examination can be obtained from instrumented underwear only if it is equipped with high-quality, flexible, textile-based electrodes guaranteeing low contact resistance with the skin. The main objective of this article is to develop reliable and washable ECG monitoring underwear able to record and wirelessly send an ECG signal in real time to a smart phone and further to a cloud. The article focuses on textile electrode design and production guaranteeing optimal contact impedance. Therefore, different types of textile fabrics were coated with modified poly(3,4-ethylenedioxythiophene:poly(styrenesulfonate (PEDOT:PSS in order to develop and manufacture reliable and washable textile electrodes assembled to female underwear (bras, by sewing using commercially available conductive yarns. Washability tests of connected underwear containing textile electrodes and conductive threads were carried out up to 50 washing cycles. The influence of standardized washing cycles on the quality of ECG signals and the electrical properties of the textile electrodes were investigated and characterized.

  1. Highly sensitive room temperature ammonia gas sensor based on Ir-doped Pt porous ceramic electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Wenlong [College of pharmacy and biological engineering, Chengdu University, Chengdu, 610106 (China); Department of chemical and materials engineering, National Chin-Yi University of Technology, Taichung 411, Taiwan (China); Liu, Yen-Yu [Department of chemical and materials engineering, Tunghai University, Taichung 407, Taiwan (China); Do, Jing-Shan, E-mail: jsdo@ncut.edu.tw [Department of chemical and materials engineering, National Chin-Yi University of Technology, Taichung 411, Taiwan (China); Li, Jing, E-mail: lijing@cdu.edu.cn [College of pharmacy and biological engineering, Chengdu University, Chengdu, 610106 (China)

    2016-12-30

    Highlights: • Water vapors seem to hugely improve the electrochemical activity of the Pt and Pt-Ir porous ceramic electrodes. • The gas sensors based on the Pt and Pt-Ir alloy electrodes possess good sensing performances. • The reaction path of the ammonia on platinum has been discussed. - Abstract: Room temperature NH{sub 3} gas sensors based on Pt and Pt-Ir (Ir doping Pt) porous ceramic electrodes have been fabricated by both electroplating and sputtering methods. The properties of the gaseous ammonia sensors have been examined by polarization and chronoamperometry techniques. The influence of humidity on the features of the resulting sensors in the system has also been discussed, and the working potential was optimized. Water vapors seem to hugely improve the electrochemical activity of the electrode. With increasing the relative humidity, the response of the Pt-Ir(E)/Pt(S)/PCP sensor to NH{sub 3} gas could be enhanced remarkably, and the sensitivity increases from 1.14 to 12.06 μA ppm{sup −1} cm{sup −2} .Then we have also discussed the sensing mechanism of the Pt-Ir sensor and the result has been confirmed by X-ray photoelectron spectroscopy of the electrode surface before and after reaction in the end.

  2. A Viable Electrode Material for Use in Microbial Fuel Cells for Tropical Regions

    Directory of Open Access Journals (Sweden)

    Felix Offei

    2016-01-01

    Full Text Available Electrode materials are critical for microbial fuel cells (MFC since they influence the construction and operational costs. This study introduces a simple and efficient electrode material in the form of palm kernel shell activated carbon (AC obtained in tropical regions. The novel introduction of this material is also targeted at introducing an inexpensive and durable electrode material, which can be produced in rural communities to improve the viability of MFCs. The maximum voltage and power density obtained (under 1000 Ω load using an H-shaped MFC with AC as both anode and cathode electrode material was 0.66 V and 1.74 W/m3, respectively. The power generated by AC was as high as 86% of the value obtained with the extensively used carbon paper. Scanning electron microscopy and Denaturing Gradient Gel Electrophoresis (DGGE analysis of AC anode biofilms confirmed that electrogenic bacteria were present on the electrode surface for substrate oxidation and the formation of nanowires.

  3. Dynamic impedance model of the skin-electrode interface for transcutaneous electrical stimulation.

    Directory of Open Access Journals (Sweden)

    José Luis Vargas Luna

    Full Text Available Transcutaneous electrical stimulation can depolarize nerve or muscle cells applying impulses through electrodes attached on the skin. For these applications, the electrode-skin impedance is an important factor which influences effectiveness. Various models describe the interface using constant or current-depending resistive-capacitive equivalent circuit. Here, we develop a dynamic impedance model valid for a wide range stimulation intensities. The model considers electroporation and charge-dependent effects to describe the impedance variation, which allows to describe high-charge pulses. The parameters were adjusted based on rectangular, biphasic stimulation pulses generated by a stimulator, providing optionally current or voltage-controlled impulses, and applied through electrodes of different sizes. Both control methods deliver a different electrical field to the tissue, which is constant throughout the impulse duration for current-controlled mode or have a very current peak for voltage-controlled. The results show a predominant dependence in the current intensity in the case of both stimulation techniques that allows to keep a simple model. A verification simulation using the proposed dynamic model shows coefficient of determination of around 0.99 in both stimulation types. The presented method for fitting electrode-skin impedance can be simple extended to other stimulation waveforms and electrode configuration. Therefore, it can be embedded in optimization algorithms for designing electrical stimulation applications even for pulses with high charges and high current spikes.

  4. Improving anti-adhesion performance of electrosurgical electrode assisted with ultrasonic vibration.

    Science.gov (United States)

    Yao, Guang; Zhang, Deyuan; Geng, Daxi; Jiang, Xinggang

    2018-03-01

    The electrosurgical electrode currently stands out as one of the most commonly used tools in minimally invasive surgery. In order to facilitate tissue cutting and accelerate wound healing, tissue adhesion to the electrosurgical electrode is considered as an extremely urgent problem to be solved. In this paper, a novel ultrasonic vibration assisted (UV-A) electrosurgical electrode is firstly proposed to overcome the problem of tissue sticking. The anti-adhesion effects were evaluated by measuring the adhesion force and the weight of tissue adhesion using the electrosurgical electrode with and without UV-A comparatively. Experimental results show that the average adhesion force and the tissue adhesion mass with UV-A were decreased by approximately 60% and 70% respectively, accompanied by smaller thermal injury area compared with that without UV-A. Moreover, the underlying mechanism of anti-adhesion effect with UV-A was revealed by investigating the influence of ultrasonic vibration on electric current, tissue removal and spark discharge. This research suggests that UV-A is a promising and practical method for improving the anti-adhesion performance of electrosurgical electrode. Copyright © 2017. Published by Elsevier B.V.

  5. 3D source localization derived from subdural strip and grid electrodes: a simulation study.

    Science.gov (United States)

    Dümpelmann, Matthias; Fell, Jürgen; Wellmer, Jörg; Urbach, Horst; Elger, Christian E

    2009-06-01

    Little experience exists in the application of source reconstruction methods to recordings from subdural strip and grid electrodes. This study addressed the question, whether reliable and accurate 3D source localization is possible from the Electrocorticogram (ECoG). The accuracy of source reconstruction was investigated by simulations and a case study. Simulated sources were used to compute potentials at the electrode positions derived from the MRI of a patient with subdural electrodes. Used procedures were the linear estimation (minimum norm) algorithm and the MUSIC (MUltiple SIgnal Classification) scan. Maxima of linear estimation were attracted to adjacent electrodes. Reliable localization with a localization error 15 mm was only achieved for about 35% of the original source positions. Maxima of the MUSIC metric were identical to original positions for simulations without noise. Noise reduced the percentage of reliable solutions down to a 79.0%. Electrode contacts distant to the source had small influence on localization accuracy. The case study supported simulation results. Reliable source reconstruction derived from ECoG can be achieved by the application of the MUSIC algorithm. Linear estimation needs additional compensation mechanisms. MUSIC based 3D localization based on ECoG has the potential improving epilepsy diagnosis and cognitive research.

  6. The electrochemical property of the electrodeposited magnetite electrode with different pH values

    International Nuclear Information System (INIS)

    Kim, Myong-Jin; Kim, Dong Jin; Kim, Hong Pyo

    2014-01-01

    Flow accelerated corrosion (FAC) is influenced by many factors such as the water chemistry (temperature, pH, dissolved oxygen (D.O.) in a solution, and etc.), chemical composition of carbon steel, and fluid dynamics. Magnetite is formed at the inner surface of carbon steel, and protects the integrity of pipes from damage. The magnetite has a stable state at each equilibrium condition, so that it can be dissolved into the fluid under conditions that satisfy the equilibrium state. The iron solubility can be calculated by considering the reaction equilibrium constants for prediction of the change in the magnetite layer. On the other hand, it is necessary to measure the experimental solubility to compare the theoretical data and the experimental data. In addition, the solubility of magnetite can be predicted by measuring the electrochemical experiments. However, there are few studies related to the electrochemical property of magnetite owing to the difficulty of the electrode fabrication. In the present work, a magnetite electrode was prepared using the electrochemical-assisted precipitation method, and the electrochemical property of the fabricated magnetite electrode was measured in an alkaline solution. The magnetite electrode was fabricated by using the electrochemical-assisted precipitation method for the measurement of the solubility of the magnetite. The prepared magnetite electrode showed the characteristic of the magnetite by an XRD spectrum

  7. Electrotonic potentials in Aloe vera L.: Effects of intercellular and external electrodes arrangement.

    Science.gov (United States)

    Volkov, Alexander G; Nyasani, Eunice K; Tuckett, Clayton; Scott, Jessenia M; Jackson, Mariah M Z; Greeman, Esther A; Greenidge, Ariane S; Cohen, Devin O; Volkova, Maia I; Shtessel, Yuri B

    2017-02-01

    Electrostimulation of plants can induce plant movements, activation of ion channels, ion transport, gene expression, enzymatic systems activation, electrical signaling, plant-cell damage, enhanced wound healing, and influence plant growth. Here we found that electrical networks in plant tissues have electrical differentiators. The amplitude of electrical responses decreases along a leaf and increases by decreasing the distance between polarizing Pt-electrodes. Intercellular Ag/AgCl electrodes inserted in a leaf and extracellular Ag/AgCl electrodes attached to the leaf surface were used to detect the electrotonic potential propagation along a leaf of Aloe vera. There is a difference in duration and amplitude of electrical potentials measured by electrodes inserted in a leaf and those attached to a leaf's surface. If the external reference electrode is located in the soil near the root, it changes the amplitude and duration of electrotonic potentials due to existence of additional resistance, capacitance, ion channels and ion pumps in the root. The information gained from this study can be used to elucidate extracellular and intercellular communication in the form of electrical signals within plants. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Anionic Surfactant Removal Using Electrochemical Process: Effect of Electrode Materials and Energy Consumption

    Directory of Open Access Journals (Sweden)

    Batoul Mohebrad

    2018-03-01

    Full Text Available The aim of this study was the investigation of electrochemical process for sodium dodecyl sulfate (SDS removal from aqueous solutions using different electrode materials. The influence of operating parameters such as current density, solution initial pH, surfactant concentrations, retention time, supporting electrolyte concentrations, electrode materials (aluminum, titanium, galvanized steel, stainless steel and electrical energy consumption were evaluated. The obtained results indicated that the stainless steel electrode was more efficient than other electrodes. Maximum SDS removal was obtained 94.98% at the optimum condition of initial pH 7.0, 60 min retention time, 3.125 mA/cm2 current density, 100 mg/L initial SDS concentration and 0.2 g/L NaCl concentration. The electrical energy consumption of stainless steel, aluminum, titanium and galvanized steel was achieved 4, 3.68, 12 and 4.48 KWh/m3, respectively. It was found that the electrochemical reaction using stainless steel plate electrodes was efficient in SDS removal from aquatic environments.

  9. Active electrode IC for EEG and electrical impedance tomography with continuous monitoring of contact impedance.

    Science.gov (United States)

    Guermandi, Marco; Cardu, Roberto; Franchi Scarselli, Eleonora; Guerrieri, Roberto

    2015-02-01

    The IC presented integrates the front-end for EEG and Electrical Impedance Tomography (EIT) acquisition on the electrode, together with electrode-skin contact impedance monitoring and EIT current generation, so as to improve signal quality and integration of the two techniques for brain imaging applications. The electrode size is less than 2 cm(2) and only 4 wires connect the electrode to the back-end. The readout circuit is based on a Differential Difference Amplifier and performs single-ended amplification and frequency division multiplexing of the three signals that are sent to the back-end on a single wire which also provides power supply. Since the system's CMRR is a function of each electrode's gain accuracy, an analysis is performed on how this is influenced by mismatches in passive and active components. The circuit is fabricated in 0.35 μm CMOS process and occupies 4 mm(2), the readout circuit consumes 360 μW, the input referred noise for bipolar EEG signal acquisition is 0.56 μVRMS between 0.5 and 100 Hz and almost halves if only EEG signal is acquired.

  10. Iodide selective membrane electrodes based on a Molybdenum-Salen as a neutral carrier

    International Nuclear Information System (INIS)

    Ghanei-Motlagh, Masoud; Taher, Mohammad Ali; Ahmadi, Kyoumars; Sheikhshoaie, Iran

    2011-01-01

    A new polymeric membrane electrode (PME) and a coated platinum disk electrode (CPtE) based on Schiff base complex of Mo(VI) as a suitable carrier for I - ion were described. The influence of membrane composition, pH and possible interfering anions were investigated on the response properties of the electrodes. The electrodes exhibited a Nernstian slope of 63.0 ± 0.5 (CPtE) and 60.3 ± 0.4 (PME) mV decade -1 in I - ion over a wide concentration range from 7.9 x 10 -7 to 1.0 x 10 -1 M for CPtE and 9.1 x 10 -6 to 1.0 x 10 -1 M I - for PME. The potentiometric response of the electrodes was independent of the pH of the test solution in the pH range 2.0-8.5 with a fast response time ( - . → The sensors have a wide concentration range with a fast response time. → Efforts have been made to improve the selectivity with the use of CPtE.

  11. A Comparison of the Effect of Square and Circular Electrodes During Defibrillation

    Science.gov (United States)

    Langrill Beaudoin, Deborah M.; Roth, Bradley J.

    2004-10-01

    The mechanism by which defibrillation-strength electric fields affect the heart has been studied extensively. Widely cited experiments designed to look at this effect incorporated plunge electrodes, made up of insulated, 21-gauge needles, to record the transmural, extracellular potential. In a previous paper (Langrill and Roth, IEEE Trans. Biomed. Eng. 48:1207-1211, 2001), we looked at the effect of a single circular plunge electrode in a passive, two-dimensional model of cardiac tissue under the influence of a defibrillation-strength electric field. In a more recent paper, we looked at 9 square plunge electrodes. It is our hypothesis that the shape of the electrode does not make a significant difference in the response of the tissue to the electric field. We perform the same simulations as in the circular plunge electrode paper and compare the two sets of data. We find that although there are some quantitative differences between the two shapes, the overall response is nearly identical.

  12. ELECTRODE SELECTION FOR RECOVERY OF THE CYLINDER LIDS OF THE TGM8K LOCOMITIVE ENGINE

    Directory of Open Access Journals (Sweden)

    Pablo Oñoz Gutiérrez

    2017-01-01

    Full Text Available The objective of this work was to determine the best-suited electrode to carry out the recovery of cylinder lids (cylinders heads of the TGM8K locomotives, by applying manual welding for electric arc. The test specimens of nodular cast iron, obtained from a discarded head, which were welded with two types electrodes, ENi-CI (UTP8 and ENiFe-CI ( UTP86FN following a technology of appropriate welding were prepared. The specimens were subject of thermic fatigue tests in an experimental installation created with this purpose, in which a process of heating and more severe cooling than in the head working conditions was simulated. During the thermic fatigue tests, in the specimens welded with electrodes ENi-CI appeared cracks at the thermic influence zone after 145 cycles, while in the specimens welded with electrodes ENiFe-CI, appeared at the 585 cycles on average. Based on the study results, the authors conclude that ENiFe-CI electrodes are the best-suited for the recovery of the cylinder lids.

  13. Washable and Reliable Textile Electrodes Embedded into Underwear Fabric for Electrocardiography (ECG) Monitoring.

    Science.gov (United States)

    Ankhili, Amale; Tao, Xuyuan; Cochrane, Cédric; Coulon, David; Koncar, Vladan

    2018-02-07

    A medical quality electrocardiogram (ECG) signal is necessary for permanent monitoring, and an accurate heart examination can be obtained from instrumented underwear only if it is equipped with high-quality, flexible, textile-based electrodes guaranteeing low contact resistance with the skin. The main objective of this article is to develop reliable and washable ECG monitoring underwear able to record and wirelessly send an ECG signal in real time to a smart phone and further to a cloud. The article focuses on textile electrode design and production guaranteeing optimal contact impedance. Therefore, different types of textile fabrics were coated with modified poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) in order to develop and manufacture reliable and washable textile electrodes assembled to female underwear (bras), by sewing using commercially available conductive yarns. Washability tests of connected underwear containing textile electrodes and conductive threads were carried out up to 50 washing cycles. The influence of standardized washing cycles on the quality of ECG signals and the electrical properties of the textile electrodes were investigated and characterized.

  14. Development of membrane selective electrode for determination of the antipsychotic sulpiride in pharmaceuticals and urine.

    Science.gov (United States)

    García, Ma Soledad; Ortuño, Joaquín A; Albero, Ma Isabel; Abuherba, Mustafa Salem

    2009-01-01

    The construction and electrochemical response characteristics of a poly(vinyl chloride) (PVC) membrane selective electrode for the determination of sulpiride (SPD) are described. The sensing membrane comprised an ion-exchanger formed between the protonated drug and tetraphenylborate (TPB(-)) in a plasticized PVC matrix. The influence of membrane composition on the electrode response was studied. The electrode showed a fast, stable and Nernstian response over a sulpiride concentration range (1 × 10(-4) - 1 × 10(-2) M) with a mean slope of 58.4 ± 0.9 mV dec(-1) of concentration, a mean detection limit of 4.2 × 10(-5) ± 1.2 × 10(-5) M, a wide working pH range (2 - 8) and a fast response time (< 15 s). The electrode showed good selectivity towards sulpiride with respect to some inorganic and organic compounds. When the electrode was applied to the determination of sulpiride in pharmaceuticals and human urine, a high percentage of recovery was attained with no need for sample pretreatment procedures because of the lack of interfering matrix effects.

  15. Development of Membrane Selective Electrode for Determination of the Antipsychotic Sulpiride in Pharmaceuticals and Urine

    Directory of Open Access Journals (Sweden)

    Mª Isabel Albero

    2009-06-01

    Full Text Available The construction and electrochemical response characteristics of a poly(vinyl chloride (PVC membrane selective electrode for the determination of sulpiride (SPD are described. The sensing membrane comprised an ion-exchanger formed between the protonated drug and tetraphenylborate (TPB- in a plasticized PVC matrix. The influence of membrane composition on the electrode response was studied. The electrode showed a fast, stable and Nernstian response over a sulpiride concentration range (1 × 10-4– 1 × 10-2 M with a mean slope of 58.4 ± 0.9 mV dec-1 of concentration, a mean detection limit of 4.2 × 10-5 ± 1.2 × 10-5 M, a wide working pH range (2 – 8 and a fast response time (< 15 s. The electrode showed good selectivity towards sulpiride with respect to some inorganic and organic compounds. When the electrode was applied to the determination of sulpiride in pharmaceuticals and human urine, a high percentage of recovery was attained with no need for sample pretreatment procedures because of the lack of interfering matrix effects.

  16. Tunneling magnetoresistance phenomenon utilizing graphene magnet electrode

    DEFF Research Database (Denmark)

    Hashimoto, T.; Kamikawa, S.; Soriano, D.

    2014-01-01

    Using magnetic rare-metals for spintronic devices is facing serious problems for the environmental contamination and the limited material-resource. In contrast, by fabricating ferromagnetic graphene nanopore arrays (FGNPAs) consisting of honeycomb-like array of hexagonal nanopores with hydrogen....../SiO2/FGNPA electrode, serving as a prototype structure for future rare-metal free TMR devices using magnetic graphene electrodes. Gradual change in TMR ratios is observed across zero-magnetic field, arising from specified alignment between pore-edge- and cobalt-spins. The TMR ratios can be controlled...

  17. Electrode potential and selective ionic adsorption

    Energy Technology Data Exchange (ETDEWEB)

    Alexe-Ionescu, A.L. [University Politehnica of Bucharest, Faculty of Applied Sciences, Splaiul Independentei 313, 060042 Bucharest (Romania); Dipartimento di Fisica, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino (Italy); Laboratory for Engineering of the Neuromuscular System, and Dipartimento di Elettronica, Corso Duca degli Abruzzi 24, 10129 Torino (Italy); Barbero, G. [Dipartimento di Fisica, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino (Italy)], E-mail: giovanni.barbero@polito.it; Merletti, R. [Laboratory for Engineering of the Neuromuscular System, and Dipartimento di Elettronica, Corso Duca degli Abruzzi 24, 10129 Torino (Italy)

    2009-04-27

    A simple description of the electrode potential based on the selective ionic adsorption is proposed. It is shown that if the adsorption-desorption coefficients entering in the Langmuir kinetic equation for the adsorption at the limiting surfaces are not identical, a difference of potential between the electrode and the bulk of the solution exists. In the case where the thickness of the sample is large with respect to the length of Debye, this difference of potential depends only on the adsorption-desorption coefficients and on the length of Debye of the ionic solution.

  18. Plasma electrode pockels cell for ICF lasers

    International Nuclear Information System (INIS)

    Rhodes, M.A.; Boley, C.D.; Tarditi, A.G.; Bauer, B.S.

    1995-01-01

    In a plasma-electrode Pockels cell (PEPC), plasma discharges serve as transparent electrodes on each side of, an electrooptic crystal such as KDP. These plasmas facilitate rapid and uniform charging and discharging of the crystal. The authors describe PEPC technology deployed on Beamlet and envisioned for the National Ignition Facility. Performance on Beamlet is discussed in detail. They also discuss models which have shed light on PEPC operation. These models describe both the high-voltage sheath that forms near the crystal surface and the characteristics of the bulk plasma column

  19. The electrochemical impedance of metal hydride electrodes

    DEFF Research Database (Denmark)

    Valøen, Lars Ole; Lasia, Andrzej; Jensen, Jens Oluf

    2002-01-01

    , explaining the experimental impedances in a wide frequency range for electrodes of hydride forming materials mixed with copper powder, were obtained. Both charge transfer and spherical diffusion of hydrogen in the particles are important sub processes that govern the total rate of the electrochemical...... hydrogen absorption/desorption reaction. To approximate the experimental data, equations describing the current distribution in porous electrodes were needed. Indications of one or more parallel reduction/oxidation processes competing with the electrochemical hydrogen absorption/desorption reaction were...

  20. Effect of oxidation of carbon material on suspension electrodes for flow electrode capacitive deionization.

    Science.gov (United States)

    Hatzell, Kelsey B; Hatzell, Marta C; Cook, Kevin M; Boota, Muhammad; Housel, Gabrielle M; McBride, Alexander; Kumbur, E Caglan; Gogotsi, Yury

    2015-03-03

    Flow electrode deionization (FCDI) is an emerging area for continuous and scalable deionization, but the electrochemical and flow properties of the flow electrode need to be improved to minimize energy consumption. Chemical oxidation of granular activated carbon (AC) was examined here to study the role of surface heteroatoms on rheology and electrochemical performance of a flow electrode (carbon slurry) for deionization processes. Moreover, it was demonstrated that higher mass densities could be used without increasing energy for pumping when using oxidized active material. High mass-loaded flow electrodes (28% carbon content) based on oxidized AC displayed similar viscosities (∼21 Pa s) to lower mass-loaded flow electrodes (20% carbon content) based on nonoxidized AC. The 40% increased mass loading (from 20% to 28%) resulted in a 25% increase in flow electrode gravimetric capacitance (from 65 to 83 F g(-1)) without sacrificing flowability (viscosity). The electrical energy required to remove ∼18% of the ions (desalt) from of the feed solution was observed to be significantly dependent on the mass loading and decreased (∼60%) from 92 ± 7 to 28 ± 2.7 J with increased mass densities from 5 to 23 wt %. It is shown that the surface chemistry of the active material in a flow electrode effects the electrical and pumping energy requirements of a FCDI system.