WorldWideScience

Sample records for attenuated total reflectance

  1. Monitoring the catalytic synthesis of glycerol carbonate by real-time attenuated total reflection FTIR spectroscopy

    NARCIS (Netherlands)

    Calvino-Casilda, V.; Mul, G.; Fernandez, J.F.; Rubio-Marcos, F.; Banares, M.A.

    2011-01-01

    In situ Attenuated Total Reflectance FTIR spectroscopy was used to study the carbonylation of glycerol with urea. Cobalt oxide nanoparticles, Co3O4, hierarchically dispersed on zinc oxide microparticles, ZnO, were used as catalysts. The present work demonstrates that in situ real-time attenuated tot

  2. Orientation of melittin in phospholipid bilayers. A polarized attenuated total reflection infrared study.

    OpenAIRE

    Frey, S.; Tamm, L K

    1991-01-01

    The helical order parameter of the 26-residue amphiphilic bee venom peptide melittin was measured by polarized attenuated total reflection infrared spectroscopy (ATR-IR) in dry phospholipid multibilayers (MBLs) and when bound to single supported planar bilayers (SPBs) under D2O. Melittin adopted an alpha-helical conformation in MBLs of dipalmitoyl-phosphatidylcholine (DPPC), 1-palmitoyl-2-oleoyl-phosphatidylcholine (POPC), a 4:1 mixture of POPC and 1-palmitoyl-2-oleoyl-phosphatidylglycerol (P...

  3. Local temperature variation measurement by anti-Stokes luminescence in attenuated total reflection geometry.

    Science.gov (United States)

    Yamamoto, Ken; Togawa, Ryotaro; Fujimura, Ryushi; Kajikawa, Kotaro

    2016-08-22

    Strong temperature dependence of anti-Stokes luminescence intensity from Rhodamine 101 is used to probe local temperature variation at a surface region in the attenuated total reflection geometry (ATR), when heating with laser light. In this method, the measured region can be limited by observing evanescent luminescence. The near-field depth (penetration depth) was changed by the observation angle θout of the evanescent luminescence and the spatial temperature variation was observed. PMID:27557182

  4. Quantitative measurement of permeabilization of living cells by terahertz attenuated total reflection

    Science.gov (United States)

    Grognot, Marianne; Gallot, Guilhem

    2015-09-01

    Using Attenuated Total Reflection imaging technique in the terahertz domain, we demonstrate non-invasive, non-staining real time measurements of cytoplasm leakage during permeabilization of epithelial cells by saponin. The terahertz signal is mostly sensitive to the intracellular protein concentration in the cells, in a very good agreement with standard bicinchoninic acid protein measurements. It opens the way to in situ real time dynamics of protein content and permeabilization in live cells.

  5. Anisotropy in Thermo-Optic Coefficient of Different Polymer Systems by Attenuated Total Reflection Configuration

    Institute of Scientific and Technical Information of China (English)

    LI Xiang; CAO Zhuang-Qi; SHEN Qi-Shun; MENG Qing-Hua; HUANG De-Ying; GUO Kun-Peng; QIU Ling; SHEN Yu-Quan

    2006-01-01

    @@ Thermo-optic coefficient dn/dT as well as volume expansion coefficients β of different polymer systems are measured for both TE and TM polarizations in an attenuated total reflection (ATR) configuration. Experimental results indicate that cross-linked polymer systems exhibit the thermal expansion coefficients smaller than those of the original side-chain systems. Moreover, the anisotropies in thermo-optic coefficients of the polymer systems with small birefringence exhibit linear relationship with the anisotropies in volume expansion coefficients, but the polymer systems with larger birefringence exhibit more complicated relationship.

  6. Rapid determination of total trans fat content--an attenuated total reflection infrared spectroscopy international collaborative study.

    Science.gov (United States)

    Mossoba, M M; Adam, M; Lee, T; Bastyr, J

    2001-01-01

    Interest in trans fat labeling has prompted efforts to develop new, more efficient methods for rapidly and accurately determining trans fat content of foods. A novel and rapid (5 min) attenuated total reflection-Fourier transform infrared (ATR-FTIR) spectroscopic procedure was recently developed and applied to food products. This procedure was voted official method AOCS Cd 14d-99 by the American Oil Chemists' Society in 1999 after testing in a 12 laboratory international collaborative study. The results of the study are described in this paper. Analytical ATR-FTIR results exhibited high accuracy in the range 5-40% trans; results tended to have internal reflection method was found to be superior to the precision of transmission infrared official methods. It is recommended that the applicability of the ATR-FTIR method be limited to trans levels of >5% (as percent of total fat). PMID:11501916

  7. Modeling the attenuated total reflectance infrared (ATR-FTIR) spectrum of apatite

    Science.gov (United States)

    Aufort, Julie; Ségalen, Loïc; Gervais, Christel; Brouder, Christian; Balan, Etienne

    2016-06-01

    Attenuated total reflectance (ATR) infrared spectra were measured on a synthetic and a natural fluorapatite sample. A modeling approach based on the computation of the Fresnel reflection coefficient between the ATR crystal and the powder sample was used to analyze the line shape of the spectra. The dielectric properties of the samples were related to those of pure fluorapatite using an effective medium approach, based on Maxwell-Garnett and Bruggeman models. The Bruggeman effective medium model leads to a very good agreement with the experimental data recorded on the synthetic fluorapatite sample. The poorer agreement observed on the natural sample suggests a more significant heterogeneity of the sample at a characteristic length scale larger than the mid-infrared characteristic wavelength, i.e., about 10 micrometers. The results demonstrate the prominent role of macroscopic electrostatic effects over fine details of the microscopic structure in determining the line shape of strong ATR bands.

  8. Mix ratio measurements of pozzolanic blends by Fourier transform infrared-attenuated total reflectance method

    International Nuclear Information System (INIS)

    The disposal of low-level radioactive liquid wastes at the Hanford Site near Richland, Washington, involves mixing the wastes with pozzolanic grout-forming solid blends. Checking the quality of each blend component and its mix ratio will ensure processibility of the blend and the long-term performance of the resulting waste grout. In earlier work at Hanford laboratories, Fourier transform infrared-transmission method (FTIR-TR) using KBr pellet was applied successfully in the analysis of blends consisting of cement, fly ash, and clays. This method involves time-consuming sample preparation resulting in slow turnaround for repetitive sampling. Because reflection methods do not require elaborate sample preparation, they have the potential to reduce turnaround analysis time. Neat samples may be examined making these methods attractive for quality control. This study investigates the capability of Fourier transform infrared-attenuated total reflectance method (FTIR-ATR) to analyze pozzolanic blends

  9. Polarized infrared attenuated total reflection study of sapphire crystals with different crystallographic planes

    Science.gov (United States)

    Lee, S. C.; Ng, S. S.; Hassan, H. Abu; Dumelow, T.

    2015-04-01

    Polarized infrared (IR) attenuated total reflection (ATR) measurements were performed on c- (polar) and r-plane (semi-polar) sapphire crystals. For c-plane sapphire crystal, spectral features due to the surface phonon polariton (SPhP) modes are only observable in the p-polarized ATR spectrum. Calculation of the SPhP dispersion spectra revealed that the SPhP modes of r-plane sapphire crystal are possible to be observed in both the s- and p-polarized ATR spectra. ATR measurements verified that excitation of the SPhP modes are still easier in the p-polarized ATR spectra. Taking into account the effects of anisotropy and the crystal orientation of hexagonal crystal system, the ATR spectra of r-plane sapphire crystal with arbitrary orientations were simulated. Through a best fit of experimental with simulated spectra, information about the crystal orientation of sapphire crystals was deduced.

  10. [Application of Fourier transform attenuated total reflection infrared spectroscopy in analysis of pulp and paper industry].

    Science.gov (United States)

    Zhang, Yong; Cao, Chun-yu; Feng, Wen-ying; Xu, Ming; Su, Zhen-hua; Liu, Xiao-meng; Lü, Wei-jun

    2011-03-01

    As one of the most powerful tools to investigate the compositions of raw materials and the property of pulp and paper, infrared spectroscopy has played an important role in pulp and paper industry. However, the traditional transmission infrared spectroscopy has not met the requirements of the producing processes because of its disadvantages of time consuming and sample destruction. New technique would be needed to be found. Fourier transform attenuated total reflection infrared spectroscopy (ATR-FTIR) is an advanced spectroscopic tool for nondestructive evaluation and could rapidly, accurately estimate the production properties of each process in pulp and paper industry. The present review describes the application of ATR-FTIR in analysis of pulp and paper industry. The analysis processes will include: pulping, papermaking, environmental protecting, special processing and paper identifying. PMID:21595211

  11. In situ probing of surface hydrides on hydrogenated amorphous silicon using attenuated total reflection infrared spectroscopy

    CERN Document Server

    Kessels, W M M; Sanden, M C M; Aydil, E S

    2002-01-01

    An in situ method based on attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) is presented for detecting surface silicon hydrides on plasma deposited hydrogenated amorphous silicon (a-Si:H) films and for determining their surface concentrations. Surface silicon hydrides are desorbed by exposing the a-Si:H films to low energy ions from a low density Ar plasma and by comparing the infrared spectrum before and after this low energy ion bombardment, the absorptions by surface hydrides can sensitively be separated from absorptions by bulk hydrides incorporated into the film. An experimental comparison with other methods that utilize isotope exchange of the surface hydrogen with deuterium showed good agreement and the advantages and disadvantages of the different methods are discussed. Furthermore, the determination of the composition of the surface hydrogen bondings on the basis of the literature data on hydrogenated crystalline silicon surfaces is presented, and quantification of the h...

  12. Unidirectional excitation of graphene plasmon in attenuated total reflection (ATR) configuration

    Energy Technology Data Exchange (ETDEWEB)

    Dai, Wei [Hubei University of Education, Wuhan (China). School of Physics and Mechanical and Electrical Engineering; Wu, Yue-Chao [Nanyang Technological University, Singapore (Singapore). Div. of Physics and Applied Physics; Liu, Fang-Li [Maryland Univ., College Park, MD (United States). Joint Quantum Institute

    2016-08-01

    Graphene plasmon has been attracting interests from both theoretical and experimental research due to its gate tunability and potential applications in the terahertz frequency range. Here, we propose an effective scheme to unidirectionally excite the graphene plasmon by exploiting magneto-optical materials in the famous attenuated total reflection (ATR) configuration. We show that the graphene plasmon dispersion relation in such a device is asymmetric in different exciting directions, thus making it possible to couple the incident light unidirectionally to the propagating plasmon. The split of absorption spectrum of graphene clearly indicates that under a magnetic field for one single frequency, graphene plasmon can only be excited in one direction. The possible gate tunablity of excitation direction and the further application of the proposed scheme, such as optical isolator, also are discussed.

  13. Attenuated total reflection Fourier-transform infrared (ATR-FTIR) imaging of tissues and live cells.

    Science.gov (United States)

    Andrew Chan, K L; Kazarian, Sergei G

    2016-03-29

    FTIR spectroscopic imaging is a label-free, non-destructive and chemically specific technique that can be utilised to study a wide range of biomedical applications such as imaging of biopsy tissues, fixed cells and live cells, including cancer cells. In particular, the use of FTIR imaging in attenuated total reflection (ATR) mode has attracted much attention because of the small, but well controlled, depth of penetration and corresponding path length of infrared light into the sample. This has enabled the study of samples containing large amounts of water, as well as achieving an increased spatial resolution provided by the high refractive index of the micro-ATR element. This review is focused on discussing the recent developments in FTIR spectroscopic imaging, particularly in ATR sampling mode, and its applications in the biomedical science field as well as discussing the future opportunities possible as the imaging technology continues to advance. PMID:26488803

  14. Analytical model for the excitation of leaky surface plasmon polaritons in the attenuated total reflection configuration

    Science.gov (United States)

    Jia, Hongwei; Xie, Yunya; Liu, Haitao; Zhong, Ying

    2016-05-01

    We propose a fully-analytical model for the excitation of leaky surface plasmon polariton (SPP) in the attenuated total reflection (ATR) configuration under illumination by a finite-width beam of electromagnetic wave. The model is built up on the basis of the general unconjugated-form reciprocity theorem and is able to predict the excitation amplitude and phase of the leaky SPP at a quantitative level. The validity of the model is carefully supported through a comparison with the numerical results obtained with the mode orthogonality. With the model a physical understanding of the resonant excitation of the leaky SPP is achieved and the optimal parameters such as the incidence angle and the beam width to ensure an efficient SPP excitation are demonstrated for design tasks.

  15. Unidirectional Excitation of Graphene Plasmon in Attenuated Total Reflection (ATR) Configuration

    Science.gov (United States)

    Dai, Wei; Wu, Yue-Chao; Liu, Fang-Li

    2016-04-01

    Graphene plasmon has been attracting interests from both theoretical and experimental research due to its gate tunability and potential applications in the terahertz frequency range. Here, we propose an effective scheme to unidirectionally excite the graphene plasmon by exploiting magneto-optical materials in the famous attenuated total reflection (ATR) configuration. We show that the graphene plasmon dispersion relation in such a device is asymmetric in different exciting directions, thus making it possible to couple the incident light unidirectionally to the propagating plasmon. The split of absorption spectrum of graphene clearly indicates that under a magnetic field for one single frequency, graphene plasmon can only be excited in one direction. The possible gate tunablity of excitation direction and the further application of the proposed scheme, such as optical isolator, also are discussed.

  16. Polymer mediated capillary electrophoresis with attenuated total reflectance infrared microspectroscopy detection

    International Nuclear Information System (INIS)

    Polymer mediated capillary electrophoresis (CE) using poly(diallyldimethylammonium chloride) (PDDAC) in the electrolyte with end-column single reflection attenuated total internal reflectance (ATR) Fourier transform infrared (FT-IR) microspectroscopy is presented. The terminus of the capillary is placed ∼1 μm from the internal reflectance element (IRE), at the focus of the ATR infrared microscope. Electrophoretic separations of benzenesulfonate, 1-naphthalenesulfonate and 1,5-naphthalenesulfonate in a NaCl and PDDAC electrolyte using either -11 or -15 kV are demonstrated with the CE-ATR FT-IR spectra providing identification of these compounds. Running electrolyte salt concentrations in the 0.85-1.7 M range are required due to the 50-80 mg mL-1 sample concentrations. Increasing the NaCl salt concentration improves peak resolution but also increases analysis time. A PDDAC concentration as low as 0.0075% can facilitate the separation of the aromatic sulfonates while maintaining reasonable electroosmotic flow. Etching of the germanium IRE by the applied current, which can affect the intensity of the infrared beam, is corrected by fabrication of a plastic mounting post for the IRE to prevent current conduction through the IR instrument

  17. Simulation of attenuated total reflection infrared absorbance spectra: applications to automotive clear coat forensic analysis.

    Science.gov (United States)

    Lavine, Barry K; Fasasi, Ayuba; Mirjankar, Nikhil; Nishikida, Koichi; Campbell, Jay

    2014-01-01

    Attenuated total reflection (ATR) is a widely used sampling technique in infrared (IR) spectroscopy because minimal sample preparation is required. Since the penetration depth of the ATR analysis beam is quite shallow, the outer layers of a laminate or multilayered paint sample can be preferentially analyzed with the entire sample intact. For this reason, forensic laboratories are taking advantage of ATR to collect IR spectra of automotive paint systems that may consist of three or more layers. However, the IR spectrum of a paint sample obtained by ATR will exhibit distortions, e.g., band broadening and lower relative intensities at higher wavenumbers, compared with its transmission counterpart. This hinders library searching because most library spectra are measured in transmission mode. Furthermore, the angle of incidence for the internal reflection element, the refractive index of the clear coat, and surface contamination due to inorganic contaminants can profoundly influence the quality of the ATR spectrum obtained for automotive paints. A correction algorithm to allow ATR spectra to be searched using IR transmission spectra of the paint data query (PDQ) automotive database is presented. The proposed correction algorithm to convert transmission spectra from the PDQ library to ATR spectra is able to address distortion issues such as the relative intensities and broadening of the bands, and the introduction of wavelength shifts at lower frequencies, which prevent library searching of ATR spectra using archived IR transmission data. PMID:25014606

  18. Numerical studies of surface and bulk modes in attenuated total reflection spectra

    Institute of Scientific and Technical Information of China (English)

    Yan Bao-Rong; Lü Jian-Hong; Kong Ling-Hua; Hu Xi-Wei

    2011-01-01

    The dispersion relations of normal modes in the layered constructions are studied. In the frequency region with negative permittivity, we investigate the normal modes near the air-metal and the air-matematerial interfaces and compare them. An extra bulk mode appearing in a pass band of two media is found near the air-matematerial interface,which is different from the air-metal case. Moreover, the bulk mode will be further proved by the attenuated total reflection (ATR) technique, in which the coupling between the incident electromagnetic waves and the normal modes is studied. For p-polarized incident waves, the ATR spectra based on the Otto and the Kretschmann configurations are obtained numerically, where the dips present the excitations of the surface and bulk modes. Furthermore, we also discuss the influences of the middle layer thickness, the incident angle and the damping term on the reflection in detail. It is found that the coupling frequencies and the maximum strength are strongly dependent on the above media parameters.

  19. Characterization of Printing Inks Using DART-Q-TOF-MS and Attenuated Total Reflectance (ATR) FTIR.

    Science.gov (United States)

    Williamson, Rhett; Raeva, Anna; Almirall, Jose R

    2016-05-01

    The rise in improved and widely accessible printing technology has resulted in an interest to develop rapid and minimally destructive chemical analytical techniques that can characterize printing inks for forensic document analysis. Chemical characterization of printing inks allows for both discrimination of inks originating from different sources and the association of inks originating from the same source. Direct analysis in real-time mass spectrometry (DART-MS) and attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR) were used in tandem to analyze four different classes of printing inks: inkjets, toners, offset, and intaglio. A total of 319 samples or ~ 80 samples from each class were analyzed directly on a paper substrate using the two methods. DART-MS was found to characterize the semi-volatile polymeric vehicle components, while ATR-FTIR provided chemical information associated with the bulk components of these inks. Complimentary data results in improved discrimination when both techniques are used in succession resulting in >96% discrimination for all toners, 95% for all inkjets, >92% for all offset, and >54% for all intaglio inks. PMID:27122410

  20. Evaluation of various polyethylene as potential dosimeters by attenuated total reflectance-Fourier-transform infrared spectroscopy

    International Nuclear Information System (INIS)

    Various types of polyethylene (PE) have been evaluated in the past for use as a potential dosimeter, chiefly via the formation of an unsaturated transvinylene (TV) double-bond resulting from exposure to ionizing radiation. The utilization of attenuated total reflectance Fourier-transform infrared (ATR-FTIR) spectroscopy in characterizing TV formation in irradiated PE for a potential dosimeter has yet to be fully developed. In this initial investigation, various PE films/sheets were exposed to ionizing radiation in a high-energy 5 megaelectron volt (MeV) electron beam accelerator in the 10–500 kilogray (kGy) dose range, followed by ATR-FTIR analysis of TV peak formation at the 965 cm−1 wavenumber. There was an upward trend in TV formation for low-density polyethylene (LDPE) films and high-density polyethylene (HDPE) sheets as a function of absorbed dose in the 10–50 kGy dose range, however, the TV response could not be equated to a specific absorbed dose. LDPE film displayed a downward trend from 50 kGy to 250 kGy and then scattering up to 500 kGy; HDPE sheets demonstrated an upward trend in TV formation up to 500 kGy. For ultra-high molecular weight polyethylene (UHMWPE) sheets irradiated up to 150 kGy, TV response was equivalent to non-irradiated UHMWPE, and a minimal upward trend was observed for 200 kGy to 500 kGy. The scatter of the data for the irradiated PE films/sheets is such that the TV response could not be equated to a specific absorbed dose. A better correlation of the post-irradiation TV response to absorbed dose may be attained through a better understanding of variables. - Highlights: • Various types of PE films/sheets have been evaluated for use as a potential dosimeter. • Attenuated total reflectance FTIR spectroscopy was utilized to analyze transvinylene formation in irradiated PE films/sheets. • PE films/sheets were exposed to ionizing radiation using a 5 MeV high-energy electron beam accelerator. • Analysis of TV peak formation at

  1. [Discriminant Analysis of Lavender Essential Oil by Attenuated Total Reflectance Infrared Spectroscopy].

    Science.gov (United States)

    Tang, Jun; Wang, Qing; Tong, Hong; Liao, Xiang; Zhang, Zheng-fang

    2016-03-01

    This work aimed to use attenuated total reflectance Fourier transform infrared spectroscopy to identify the lavender essential oil by establishing a Lavender variety and quality analysis model. So, 96 samples were tested. For all samples, the raw spectra were pretreated as second derivative, and to determine the 1 750-900 cm(-1) wavelengths for pattern recognition analysis on the basis of the variance calculation. The results showed that principal component analysis (PCA) can basically discriminate lavender oil cultivar and the first three principal components mainly represent the ester, alcohol and terpenoid substances. When the orthogonal partial least-squares discriminant analysis (OPLS-DA) model was established, the 68 samples were used for the calibration set. Determination coefficients of OPLS-DA regression curve were 0.959 2, 0.976 4, and 0.958 8 respectively for three varieties of lavender essential oil. Three varieties of essential oil's the root mean square error of prediction (RMSEP) in validation set were 0.142 9, 0.127 3, and 0.124 9, respectively. The discriminant rate of calibration set and the prediction rate of validation set had reached 100%. The model has the very good recognition capability to detect the variety and quality of lavender essential oil. The result indicated that a model which provides a quick, intuitive and feasible method had been built to discriminate lavender oils. PMID:27400512

  2. Evaluation of various polyethylene as potential dosimeters by attenuated total reflectance-Fourier-transform infrared spectroscopy

    Science.gov (United States)

    Halperin, Fred; Collins, Greta; DiCicco, Michael; Logar, John

    2014-12-01

    Various types of polyethylene (PE) have been evaluated in the past for use as a potential dosimeter, chiefly via the formation of an unsaturated transvinylene (TV) double-bond resulting from exposure to ionizing radiation. The utilization of attenuated total reflectance Fourier-transform infrared (ATR-FTIR) spectroscopy in characterizing TV formation in irradiated PE for a potential dosimeter has yet to be fully developed. In this initial investigation, various PE films/sheets were exposed to ionizing radiation in a high-energy 5 megaelectron volt (MeV) electron beam accelerator in the 10-500 kilogray (kGy) dose range, followed by ATR-FTIR analysis of TV peak formation at the 965 cm-1 wavenumber. There was an upward trend in TV formation for low-density polyethylene (LDPE) films and high-density polyethylene (HDPE) sheets as a function of absorbed dose in the 10-50 kGy dose range, however, the TV response could not be equated to a specific absorbed dose. LDPE film displayed a downward trend from 50 kGy to 250 kGy and then scattering up to 500 kGy; HDPE sheets demonstrated an upward trend in TV formation up to 500 kGy. For ultra-high molecular weight polyethylene (UHMWPE) sheets irradiated up to 150 kGy, TV response was equivalent to non-irradiated UHMWPE, and a minimal upward trend was observed for 200 kGy to 500 kGy. The scatter of the data for the irradiated PE films/sheets is such that the TV response could not be equated to a specific absorbed dose. A better correlation of the post-irradiation TV response to absorbed dose may be attained through a better understanding of variables.

  3. Attenuated total reflection-Fourier transform infrared spectroscopic imaging of pharmaceuticals in microfluidic devices.

    Science.gov (United States)

    Ewing, Andrew V; Clarke, Graham S; Kazarian, Sergei G

    2016-03-01

    The poor aqueous solubility of many active pharmaceutical ingredients presents challenges for effective drug delivery. In this study, the combination of attenuated total reflection (ATR)-FTIR spectroscopic imaging with specifically designed polydimethylsiloxane microfluidic devices to study drug release from pharmaceutical formulations has been developed. First, the high-throughput analysis of the dissolution of micro-formulations studied under flowing conditions has been introduced using a model formulation of ibuprofen and polyethylene glycol. The behaviour and release of the drug was monitored in situ under different pH conditions. In contrast to the neutral solution, where both the drug and excipient dissolved at a similar rate, structural change from the molecularly dispersed to a crystalline form of ibuprofen was characterised in the obtained spectroscopic images and the corresponding ATR-FTIR spectra for the experiments carried out in the acidic medium. Further investigations into the behaviour of the drug after its release from formulations (i.e., dissolved drug) were also undertaken. Different solutions of sodium ibuprofen dissolved in a neutral medium were studied upon contact with acidic conditions. The phase transition from a dissolved species of sodium ibuprofen to the formation of solid crystalline ibuprofen was revealed in the microfluidic channels. This innovative approach could offer a promising platform for high-throughput analysis of a range of micro-formulations, which are of current interest due to the advent of 3D printed pharmaceutical and microparticulate delivery systems. Furthermore, the ability to study dissolved drug in solution under flowing conditions can be useful for the studies of the diffusion of drugs into tissues or live cells. PMID:27158293

  4. Modeling and Forecasting of Depletion of Additives in Car Engine Oils Using Attenuated Total Reflectance Fast Transform Infrared Spectroscopy

    OpenAIRE

    Ronald Nguele; Hikmat Said Al-Salim; Khalid Mohammad

    2014-01-01

    On average, additives make up to 7% of a typical lubricant base. Commonly, they are blended with lube oils to enhance specific features thereby improving their qualities. Ultimately, additives participate in the performance of car engine oils. Using an analytical tool, attenuated total reflectance fast transform infrared spectroscopy, various grades of car engine oils, at different mileages, were analyzed. Sulfate oxidation and wear were found to trigger chemical processes which, in the long ...

  5. Complexation of polyacrylates by Ca2+ ions. Time-resolved studies using attenuated total reflectance Fourier transform infrared dialysis spectroscopy.

    Science.gov (United States)

    Fantinel, Fabiana; Rieger, Jens; Molnar, Ferenc; Hübler, Patrick

    2004-03-30

    The attenuated total reflectance Fourier transform infrared dialysis technique is introduced for the time-resolved investigation of the binding processes of Ca2+ to polyacrylates dissolved in water. We observed transient formation of intermediates in water with various types of coordination of the carboxylate group to Ca2+ throughout the complexation steps. Time-resolved changes in the spectra were analyzed with principal component analysis, from which the spectral species were obtained as well as their formation kinetics. We propose a model for the mechanisms of Ca2+ coordination to polyacrylates. The polymer chain length plays an important role in Ca2+ binding. PMID:15835120

  6. Determination of Optical Constants in the Mid-Infrared Spectral Range by use of the Attenuated Total Reflection Method

    Directory of Open Access Journals (Sweden)

    Biliškov, N:

    2010-01-01

    Full Text Available Infrared (IR spectroscopy is one of the most useful experimental methods in the investigation of hydrogen-bonded systems. However, application of transmission IR spectroscopy to aqueous systems is only of limited value due to the very strong water absorption. The necessity of very short pathlengths to obtain quantitative spectra is accompanied by very low reproducibility of the spectra obtained in such a way. However, in the last two decades, a reliable procedure which allows the calculation of optical constants [real n and imaginary k part of the complex refraction index n] from the spectra obtained by use of the attenuated total reflection (ATR techniquepATR, has enabled a very accurate quantitative IR spectroscopy of liquid systems containing water.The use of calibrated infrared attenuated total reflection spectroscopy is discussed in the present work. The paper is organised as follows. After a short introduction, a theoretical clarification of processes corresponding to the attenuated total reflection is given. Here, an analysis of the processthrough Fresnel equations is followed by the discussion of the specific terms, such as effective number of reflections and penetration depth. In these terms, the difference between spectra obtained by transmission A and by ATR pATR was explained, specifying also the relation, through optical constants n and k, between these two forms of the IR spectra of the same system.The next section discusses the most reliable and up-to-date method for determining the optical constants of the ATR spectra, provided by Bertie and Lan (J. E. Bertie, Z. Lan, J. Chem. Phys. 105 (1996 8502. This method calculates optical constants from s-polarised ATR spectra by a modified Kramers-Krönig transform of the reflectance Rs to the phase shift on reflection Θs. However, the method is developed only for the specific conditions of the ATR experiment, i. e. for CIRCLE cell, with a 45° incident angle and with equal intensities

  7. p-polarized infrared attenuated total reflection study of InN thin films grown on Si(111) substrate

    Energy Technology Data Exchange (ETDEWEB)

    Ng, S.S.; Lee, S.C.; Ooi, P.K.; Hassan, Z.; Abu Hassan, H. [Nano-Optoelectronic Research Laboratory, School of Physics, Universiti Sains Malaysia, 11800 Penang (Malaysia); Chen, W.L. [Department of Electronic Engineering, National Changhua University of Education, Taiwan 500 (China)

    2010-09-15

    We report for the first time the surface phonon polariton (SPP) and interface phonon polariton (IPP) characteristics of InN thin films grown on AlN buffer layer on Si(111) substrate by molecular beam epitaxy. The p-polarized infrared attenuated total reflection technique was used to excite the SPP and IPP modes of the sample. It was found that the SPP mode of InN and the IPP mode of InN/AlN were clearly ob- served at 609 cm{sup -1} and 877 cm{sup -1}, respectively. The origins of the observed peaks were verified by theoretical simulations based on the anisotropic model. In general, a good agreement between the experimental and theoretical results was obtained. Finally, the effect of the free carriers on the SPP mode is discussed. (copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  8. Application of attenuated total reflectance Fourier transform infrared spectroscopy for determination of cefixime in oral pharmaceutical formulations

    Science.gov (United States)

    Kandhro, Aftab A.; Laghari, Abdul Hafeez; Mahesar, Sarfaraz A.; Saleem, Rubina; Nelofar, Aisha; Khan, Salman Tariq; Sherazi, S. T. H.

    2013-11-01

    A quick and reliable analytical method for the quantitative assessment of cefixime in orally administered pharmaceutical formulations is developed by using diamond cell attenuated total reflectance (ATR) Fourier transform infrared (FT-IR) spectroscopy as an easy procedure for quality control laboratories. The standards for calibration were prepared in aqueous medium ranging from 350 to 6000 mg/kg. The calibration model was developed based on partial least square (PLS) using finger print region of FT-IR spectrum in the range from 1485 to 887 cm-1. Excellent coefficient of determination (R2) was achieved as high as 0.99976 with root mean square error of 44.8 for calibration. The application of diamond cell (smart accessory) ATR FT-IR proves a reliable determination of cefixime in pharmaceutical formulations to assess the quality of the final product.

  9. Changes in the infrared attenuated total reflectance (ATR spectra of lignins from alfalfa stem with growth and development

    Directory of Open Access Journals (Sweden)

    JORDAN P. MARKOVIĆ

    2009-08-01

    Full Text Available Lignin is a poorly characterized polymer and its exact properties vary depending on both the species of the plant and its location within the plant. Three classes of lignins taken from alfalfa stem were examined. The investigation was concentrated on the determination of chemical changes in the lignins during growth and development by the attenuated total reflectance (ATR infrared (IR spectrometric technique. The spectrum of permanganate lignin was comparable to that of acid detergent lignin. The main differences were in the different relative absorbance of the peaks. The predominant component of acid detergent lignin and permanganate lignin was guaiacyl-type lignin. The predominant component of Klason lignin was syringyl-type lignin. A comparison between the signals from lignin in different development stages revealed the appearance of new peaks, which are indications of new bonds and changes in the structure of the lignins.

  10. Determination of antioxidant capacity and phenolic content of chocolate by attenuated total reflectance-Fourier transformed-infrared spectroscopy.

    Science.gov (United States)

    Hu, Yaxi; Pan, Zhi Jie; Liao, Wen; Li, Jiaqi; Gruget, Pierre; Kitts, David D; Lu, Xiaonan

    2016-07-01

    Antioxidant capacity and phenolic content of chocolate, containing different amounts of cacao (35-100%), were determined using attenuated total reflectance (ATR)-Fourier transformed-infrared (FT-IR) spectroscopy (4000-550cm(-1)). Antioxidant capacities were first characterized using DPPH (2,2-diphenyl-1-picrylhydrazyl) and ORAC (oxygen radical absorbance capacity) assays. Phenolic contents, including total phenol and procyanidins monomers, were quantified using the Folin-Ciocalteu assay and high performance liquid chromatography coupled with photodiode array detector (HPLC-DAD), respectively. Five partial least-squares regression (PLSR) models were constructed and cross-validated using FT-IR spectra from 18 types of chocolate and corresponding reference values determined using DPPH, ORAC, Folin-Ciocalteu, and HPLC assays. The models were validated using seven unknown samples of chocolate. PLSR models showed good prediction capability for DPPH [R(2)-P (prediction)=0.88, RMSEP (root mean squares error of prediction)=12.62μmol Trolox/g DFW], ORAC (R(2)-P=0.90, RMSEP=37.92), Folin-Ciocalteu (R(2)-P=0.88, RMSEP=5.08), and (+)-catechin (R(2)-P=0.86, RMSEP=0.10), but lacked accuracy in the prediction of (-)-epicatechin (R(2)-P=0.72, RMSEP=0.57). ATR-FT-IR spectroscopy can be used for rapid prediction of antioxidant capacity, total phenolic content, and (+)-catechin in chocolate. PMID:26920292

  11. Attenuated total reflection fourier transform infrared spectroscopy towards disclosing mechanism of bacterial adhesion on thermally stabilized titanium nano-interfaces.

    Science.gov (United States)

    Gopal, Judy; Chun, Sechul; Doble, Mukesh

    2016-08-01

    Titanium is widely used as medical implant material and as condenser material in the nuclear industry where its integrity is questioned due to its susceptibility to bacterial adhesion. A systematic investigation on the influence of thermally (50-800 °C) stabilized titanium (TS-Ti) nano oxide towards bacterial adhesion was carried out. The results showed that below 350 °C significant bacterio-phobicity was observed, while above 500 °C significant affinity towards bacterial cells was recorded. Conventional characterization tools such as HR-TEM and XRD did not provide much insight on the changes occurring on the oxide film with heat treatment, however, attenuated total reflection fourier transform infrared spectroscopy (ATR-FTIR) of the surface showed significant changes in the spectral pattern as a function of increasing heat treatment. It was observed that elevated OH, N-H and C=O groups and rutile titania on the TS-Ti oxide films led to higher affinity for bacterial adhesion. On the other hand low temperature TS-Ti nanooxide films (film grown at 50 °C was observed to be the most efficient anti-bacterial adhesion interface, while the 800 °C interface was the one showing highest affinity towards bacterial adhesion. This study confirms the successful application of ATR-FTIR technique for nano-oxide film characterization and towards understanding the variations in bacterial interaction of such nano interfaces. PMID:27412653

  12. Characterization of nasal paraffinoma following septorhinoplasty by attenuated total reflection--fourier transform infrared spectroscopy (ATR-FTIR).

    Science.gov (United States)

    Gil-Carcedo, Luis M; Martín-Gil, Jesús; Gil-Carcedo, Elisa S; Vallejo, Luis A; Martín-Gil, Francisco J

    2006-06-01

    Vaseline and paraffin have been injected into various parts of the body. Vaselinoma and paraffinoma are well-described complications, despite which nasal packing with Vaseline gauze is still common in the management of epistaxis, after rhinoplasty, endonasal surgery, to control bleeding and prevent synechiae or restenosis. Our aim is to highlight this complication, propose a safe method for its diagnosis and establish guidelines for its prevention. We report two cases of paraffinoma occurring after rhinoplasty and discuss prevention of this rare but serious complication, and suggest an alternative dressing. Attenuated total reflection (ATR) FI7R spectra have proven to be a definitive characterising tool for surgical extracts, guaranteeing detection of mineral products that histology does not offer. For these lesions we propose the name "petroleum oilomas" which we feel to be more appropriate than the more commonly used paraffinomas. Relevance of the work: a description of an innovative and safe method of diagnosis, and proposal of a procedure for postrhinoplasty packing (without mineral oils) to avoid this complication. PMID:16792177

  13. Modeling and Forecasting of Depletion of Additives in Car Engine Oils Using Attenuated Total Reflectance Fast Transform Infrared Spectroscopy

    Directory of Open Access Journals (Sweden)

    Ronald Nguele

    2014-11-01

    Full Text Available On average, additives make up to 7% of a typical lubricant base. Commonly, they are blended with lube oils to enhance specific features thereby improving their qualities. Ultimately, additives participate in the performance of car engine oils. Using an analytical tool, attenuated total reflectance fast transform infrared spectroscopy, various grades of car engine oils, at different mileages, were analyzed. Sulfate oxidation and wear were found to trigger chemical processes which, in the long run, cause lubricant degradation while carbonyl oxidation was observed to occur only at a slow rate. Based upon data obtained from infrared spectra and using a curve fitting technique, mathematical equations predicting the theoretical rates of chemical change due to the aforementioned processes were examined. Additive depletions were found to obey exponential regression rather than polynomial. Moreover, breakpoint (breakpoint is used here to denote the initiation of deterioration of additives and critical mileage (critical mileage defines the distance at which the lubricant is chemically unusable of both samples were determined.

  14. Application of multibounce attenuated total reflectance fourier transform infrared spectroscopy and chemometrics for determination of aspartame in soft drinks.

    Science.gov (United States)

    Khurana, Harpreet Kaur; Cho, Il Kyu; Shim, Jae Yong; Li, Qing X; Jun, Soojin

    2008-02-13

    Aspartame is a low-calorie sweetener commonly used in soft drinks; however, the maximum usage dose is limited by the U.S. Food and Drug Administration. Fourier transform infrared (FTIR) spectroscopy with attenuated total reflectance sampling accessory and partial least-squares regression (PLS) was used for rapid determination of aspartame in soft drinks. On the basis of spectral characterization, the highest R2 value, and lowest PRESS value, the spectral region between 1600 and 1900 cm(-1) was selected for quantitative estimation of aspartame. The potential of FTIR spectroscopy for aspartame quantification was examined and validated by the conventional HPLC method. Using the FTIR method, aspartame contents in four selected carbonated diet soft drinks were found to average from 0.43 to 0.50 mg/mL with prediction errors ranging from 2.4 to 5.7% when compared with HPLC measurements. The developed method also showed a high degree of accuracy because real samples were used for calibration, thus minimizing potential interference errors. The FTIR method developed can be suitably used for routine quality control analysis of aspartame in the beverage-manufacturing sector. PMID:18181572

  15. Analysis of changes in attenuated total reflection FTIR fingerprints of Pseudomonas fluorescens from planktonic state to nascent biofilm state

    Science.gov (United States)

    Quilès, Fabienne; Humbert, François; Delille, Anne

    2010-02-01

    Attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy is a useful method for monitoring biofilm in situ, non-destructively, in real time, and under fully hydrated conditions. In this work we focused on changes in Pseudomonas fluorescens ATR-FTIR fingerprint accompanying the very early stages of biofilm formation: initial bacterial adhesion and the very beginning of biofilm development in the presence of nutrients. To help interpreting variations in the ATR-FTIR fingerprint of sessile bacteria, ATR-FTIR spectra of planktonic bacteria in different growth phases were also examined, and the average surface coverage and spatial arrangement of bacteria on the ATR crystal were determined by epifluorescence microscopy. The proteins, nucleic acids and polysaccharides ATR-FTIR spectral data recorded during growth of sessile bacteria were shown to be linked to changes in the physiological state of the bacteria, possibly accompanied by extracellular polymeric substances production. This work clearly showed by spectroscopic method how bacteria change drastically their metabolism during the first hours of biofilm formation.

  16. Rapid quantification of methamphetamine: using attenuated total reflectance fourier transform infrared spectroscopy (ATR-FTIR and chemometrics.

    Directory of Open Access Journals (Sweden)

    Juanita Hughes

    Full Text Available In Australia and increasingly worldwide, methamphetamine is one of the most commonly seized drugs analysed by forensic chemists. The current well-established GC/MS methods used to identify and quantify methamphetamine are lengthy, expensive processes, but often rapid analysis is requested by undercover police leading to an interest in developing this new analytical technique. Ninety six illicit drug seizures containing methamphetamine (0.1%-78.6% were analysed using Fourier Transform Infrared Spectroscopy with an Attenuated Total Reflectance attachment and Chemometrics. Two Partial Least Squares models were developed, one using the principal Infrared Spectroscopy peaks of methamphetamine and the other a Hierarchical Partial Least Squares model. Both of these models were refined to choose the variables that were most closely associated with the methamphetamine % vector. Both of the models were excellent, with the principal peaks in the Partial Least Squares model having Root Mean Square Error of Prediction 3.8, R(2 0.9779 and lower limit of quantification 7% methamphetamine. The Hierarchical Partial Least Squares model had lower limit of quantification 0.3% methamphetamine, Root Mean Square Error of Prediction 5.2 and R(2 0.9637. Such models offer rapid and effective methods for screening illicit drug samples to determine the percentage of methamphetamine they contain.

  17. Analysis of H2O in silicate glass using attenuated total reflectance (ATR) micro-FTIR spectroscopy

    Science.gov (United States)

    Lowenstern, Jacob B.; Pitcher, Bradley W.

    2013-01-01

    We present a calibration for attenuated total reflectance (ATR) micro-FTIR for analysis of H2O in hydrous glass. A Ge ATR accessory was used to measure evanescent wave absorption by H2O within hydrous rhyolite and other standards. Absorbance at 3450 cm−1 (representing total H2O or H2Ot) and 1630 cm−1 (molecular H2O or H2Om) showed high correlation with measured H2O in the glasses as determined by transmission FTIR spectroscopy and manometry. For rhyolite, wt%H2O=245(±9)×A3450-0.22(±0.03) and wt%H2Om=235(±11)×A1630-0.20(±0.03) where A3450 and A1630 represent the ATR absorption at the relevant infrared wavelengths. The calibration permits determination of volatiles in singly polished glass samples with spot size down to ~5 μm (for H2O-rich samples) and detection limits of ~0.1 wt% H2O. Basaltic, basaltic andesite and dacitic glasses of known H2O concentrations fall along a density-adjusted calibration, indicating that ATR is relatively insensitive to glass composition, at least for calc-alkaline glasses. The following equation allows quantification of H2O in silicate glasses that range in composition from basalt to rhyolite: wt%H2O=(ω×A3450/ρ)+b where ω = 550 ± 21, b = −0.19 ± 0.03, ρ = density, in g/cm3, and A3450 is the ATR absorbance at 3450 cm−1. The ATR micro-FTIR technique is less sensitive than transmission FTIR, but requires only a singly polished sample for quantitative results, thus minimizing time for sample preparation. Compared with specular reflectance, it is more sensitive and better suited for imaging of H2O variations in heterogeneous samples such as melt inclusions. One drawback is that the technique can damage fragile samples and we therefore recommend mounting of unknowns in epoxy prior to polishing. Our calibration should hold for any Ge ATR crystals with the same incident angle (31°). Use of a different crystal type or geometry would require measurement of several H2O-bearing standards to provide a crystal

  18. Fourier transform infrared with attenuated total reflectance applied to the discrimination of freshwater planktonic coccoid green microalgae.

    Directory of Open Access Journals (Sweden)

    Guilherme Pavan de Moraes

    Full Text Available Despite the recent advances on fine taxonomic discrimination in microorganisms, namely using molecular biology tools, some groups remain particularly problematic. Fine taxonomy of green algae, a widely distributed group in freshwater ecosystems, remains a challenge, especially for coccoid forms. In this paper, we propose the use of the Fourier Transform Infrared (FTIR spectroscopy as part of a polyphasic approach to identify and classify coccoid green microalgae (mainly order Sphaeropleales, using triplicated axenic cultures. The attenuated total reflectance (ATR technique was tested to reproducibility of IR spectra of the biological material, a primary requirement to achieve good discrimination of microalgal strains. Spectral window selection was also tested, in conjunction with the first derivative treatment of spectra, to determine which regions of the spectrum provided better separation and clustering of strains. The non-metric multidimensional scaling (NMDS, analysis of similarities (ANOSIM and hierarchical clusters (HCA, demonstrated a correct discrimination and classification of closely related strains of chlorophycean coccoid microalgae, with respect to currently accepted classifications. FTIR-ATR was highly reproducible, and provided an excellent discrimination at the strain level. The best separation was achieved by analyzing the spectral windows of 1500-1200 cm(-1 and 900-675 cm(-1, which differs from those used in previously studies for the discrimination of broad algal groups, and excluding spectral regions related to storage compounds, which were found to give poor discrimination. Furthermore, hierarchical cluster analyses have positioned the strains tested into clades correctly, reproducing their taxonomic orders and families. This study demonstrates that FTIR-ATR has great potential to complement classical approaches for fine taxonomy of coccoid green microalgae, though a careful spectrum region selection is needed.

  19. Fourier Transform Infrared with Attenuated Total Reflectance Applied to the Discrimination of Freshwater Planktonic Coccoid Green Microalgae

    Science.gov (United States)

    de Moraes, Guilherme Pavan; Vieira, Armando Augusto Henriques

    2014-01-01

    Despite the recent advances on fine taxonomic discrimination in microorganisms, namely using molecular biology tools, some groups remain particularly problematic. Fine taxonomy of green algae, a widely distributed group in freshwater ecosystems, remains a challenge, especially for coccoid forms. In this paper, we propose the use of the Fourier Transform Infrared (FTIR) spectroscopy as part of a polyphasic approach to identify and classify coccoid green microalgae (mainly order Sphaeropleales), using triplicated axenic cultures. The attenuated total reflectance (ATR) technique was tested to reproducibility of IR spectra of the biological material, a primary requirement to achieve good discrimination of microalgal strains. Spectral window selection was also tested, in conjunction with the first derivative treatment of spectra, to determine which regions of the spectrum provided better separation and clustering of strains. The non-metric multidimensional scaling (NMDS), analysis of similarities (ANOSIM) and hierarchical clusters (HCA), demonstrated a correct discrimination and classification of closely related strains of chlorophycean coccoid microalgae, with respect to currently accepted classifications. FTIR-ATR was highly reproducible, and provided an excellent discrimination at the strain level. The best separation was achieved by analyzing the spectral windows of 1500–1200 cm−1 and 900–675 cm−1, which differs from those used in previously studies for the discrimination of broad algal groups, and excluding spectral regions related to storage compounds, which were found to give poor discrimination. Furthermore, hierarchical cluster analyses have positioned the strains tested into clades correctly, reproducing their taxonomic orders and families. This study demonstrates that FTIR-ATR has great potential to complement classical approaches for fine taxonomy of coccoid green microalgae, though a careful spectrum region selection is needed. PMID:25541701

  20. Dynamics of layer-by-layer growth of a polyelectrolyte multilayer studied in situ using attenuated total reflectance infrared spectroscopy.

    Science.gov (United States)

    Owusu-Nkwantabisah, Silas; Gammana, Madhira; Tripp, Carl P

    2014-10-01

    Attenuated total reflectance infrared spectroscopy (ATR-IR) was used to study the dynamic layer-by-layer (LBL) growth of a sodium polyacrylate (NaPA)/poly(diallydimethylammonium) chloride (PDADMAC) multilayer on TiO2 particles. Molecular weights (Mw) used were 30 and 60 kDa for NaPA and 8.5 and 150 kDa for PDADMAC. IR spectra were recorded in situ as a function of time and were used to obtain the dynamic mass adsorbed and bound fraction of the polymers during each deposition step. For 30 kDa NaPA layers, the dynamics of adsorption show an initial rapid rise in mass followed by a slow increase toward a plateau value upon LBL with 150 kDa PDADMAC. In contrast, the 60 kDa NaPA layers achieve a plateau quickly and do not show a slow increase toward a plateau. In the case of LBL with 150 kDa PDADMAC, the dynamics of the bound fraction of polymer per layer suggest that polymer diffusion and conformational rearrangement occur for the layers of 30 kDa NaPA but not for the 60 kDa NaPA layers. Furthermore, PDADMAC adsorption profiles show that there is no diffusion of the PDADMAC layers and that PDADMAC flattens onto the underlying layer. A linear growth in the mass adsorbed per layer was observed for 150 kDa PDADMAC with both molecular weights of NaPA. In the case of 8.5 kDa PDADMAC, smaller growth increments and the desorption of underlying layers were observed. This work demonstrates the use of ATR-IR in obtaining the dynamics of LBL multilayer formation. Furthermore, it provides an example in which polymer diffusion during LBL film formation does not lead to exponential growth. PMID:25203136

  1. Application of the Polynomial-Based Least Squares and Total Least Squares Models for the Attenuated Total Reflection Fourier Transform Infrared Spectra of Binary Mixtures of Hydroxyl Compounds.

    Science.gov (United States)

    Shan, Peng; Peng, Silong; Zhao, Yuhui; Tang, Liang

    2016-03-01

    An analysis of binary mixtures of hydroxyl compound by Attenuated Total Reflection Fourier transform infrared spectroscopy (ATR FT-IR) and classical least squares (CLS) yield large model error due to the presence of unmodeled components such as H-bonded components. To accommodate these spectral variations, polynomial-based least squares (LSP) and polynomial-based total least squares (TLSP) are proposed to capture the nonlinear absorbance-concentration relationship. LSP is based on assuming that only absorbance noise exists; while TLSP takes both absorbance noise and concentration noise into consideration. In addition, based on different solving strategy, two optimization algorithms (limited-memory Broyden-Fletcher-Goldfarb-Shanno (LBFGS) algorithm and Levenberg-Marquardt (LM) algorithm) are combined with TLSP and then two different TLSP versions (termed as TLSP-LBFGS and TLSP-LM) are formed. The optimum order of each nonlinear model is determined by cross-validation. Comparison and analyses of the four models are made from two aspects: absorbance prediction and concentration prediction. The results for water-ethanol solution and ethanol-ethyl lactate solution show that LSP, TLSP-LBFGS, and TLSP-LM can, for both absorbance prediction and concentration prediction, obtain smaller root mean square error of prediction than CLS. Additionally, they can also greatly enhance the accuracy of estimated pure component spectra. However, from the view of concentration prediction, the Wilcoxon signed rank test shows that there is no statistically significant difference between each nonlinear model and CLS. PMID:26810185

  2. Fourier transform infrared-attenuated total reflectance (FTIR-ATR) spectroscopy and chemometric techniques for the determination of adulteration in petrodiesel/biodiesel blends

    OpenAIRE

    Armando Guerrero Peña; Francisco Anguebes Franseschi; Mepivoseth Castelán Estrada; Victorino Morales Ramos; Reyes García Zarracino; José C. Zavala Loría; Atl V. Córdova Quiroz

    2014-01-01

    We propose an analytical method based on fourier transform infrared-attenuated total reflectance (FTIR-ATR) spectroscopy to detect the adulteration of petrodiesel and petrodiesel/palm biodiesel blends with African crude palm oil. The infrared spectral fingerprints from the sample analysis were used to perform principal components analysis (PCA) and to construct a prediction model using partial least squares (PLS) regression. The PCA results separated the samples into three groups, allowing id...

  3. Orientation and lipid-peptide interactions of gramicidin A in lipid membranes: Polarized attenuated total reflection infrared spectroscopy and spin-label electron spin resonance

    OpenAIRE

    Kota, Z.; Pali, T.; Marsh, D.

    2004-01-01

    Gramicidin A was incorporated at a peptide/lipid ratio of 1:10 mol/mol in aligned bilayers of dimyristoyl phosphatidylcholine (DMPC), phosphatidylserine (DMPS), phosphatidylglycerol (DMPG), and phosphatidylethanolamine (DMPE), from trifluoroethanol. Orientations of the peptide and lipid chains were determined by polarized attenuated total reflection infrared spectroscopy. Lipid-peptide interactions with gramicidin A in DMPC bilayers were studied with different spin-labeled lipid species by us...

  4. Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy and Artificial Neural Networks Applied to Differentiate Escherichia coli papG+/papG- Strains

    OpenAIRE

    Łukasz Lechowicz; Wioletta Adamus-Białek; Wiesław Kaca

    2013-01-01

    Fimbriae are an important pathogenic factor of Escherichia coli during development of urinary tract infections. Here, we describe a new method for identification of Escherichia coli papG+ from papG- strains using the attenuated total reflectance Fourier transform infrared Spectroscopy (ATR FT-IR). We applied artificial neural networks to the analysis of the ATR FT-IR results. These methods allowed to discriminate E. coli papG+ from papG- strains with accuracy of 99%.

  5. Use of total internal reflection Raman (TIR) and attenuated total reflection infrared (ATR-IR) spectroscopy to analyze component separation in thin offset ink films after setting on coated paper surfaces.

    Science.gov (United States)

    Kivioja, Antti; Hartus, Timo; Vuorinen, Tapani; Gane, Patrick; Jääskeläinen, Anna-Stiina

    2013-06-01

    The interactive behavior of ink constituents with porous substrates during and after the offset print process has an important effect on the quality of printed products. To help elucidate the distribution of ink components between the retained ink layer and the substrate, a variety of spectroscopic and microscopic analysis techniques have been developed. This paper describes for the first time the use of total internal reflection (TIR) Raman spectroscopy to analyze the penetration behavior of separated offset ink components (linseed oil, solid color pigment) in coated papers providing chemically intrinsic information rapidly, nondestructively, and with minimal sample preparation. In addition, the already widely applied technique of attenuated total reflection infrared spectroscopy (ATR-IR) was evaluated in parallel and compared. The results of the ATR-IR Raman clearly revealed an improvement in uppermost depth resolution compared with values previously published from other nondestructive techniques, and the method is shown to be capable of providing new knowledge of the setting of thin (0.25-2 μm) offset ink films, allowing the spreading and the penetration behavior on physically different paper coating surfaces to be studied. PMID:23735252

  6. Study of interfacial reactions and phase stabilization of mixed Sc, Dy, Hf high-k oxides by attenuated total reflectance infrared spectroscopy

    OpenAIRE

    Hardy, An; Adelmann, C; Van Elshocht, S.; Van den Rul, Heidi; Van Bael, Marlies; de Gendt, S.; D'Olieslaeger, Marc; Heyns, M.; Kittl, J. A.; Mullens, Jules

    2009-01-01

    Grazing angle attenuated total reflectance Fourier transform infrared spectroscopy is applied to study ultrathin film Hf4+, Sc3+ and Dy3+ oxides, due to its high surface sensitivity. The (multi) metal oxides studied, are of interest as high-k dielectrics. Important properties affecting the permittivity, such as the amorphous or crystalline phase and interfacial reactions, are characterized. Dy2O3 is prone to silicate formation on SiO2/Si substrates, which is expressed in DyScO3 as well, but s...

  7. Concomitant Use of Fourier Transform Infrared Attenuated Total Reflectance Spectroscopy and Chemometrics for Quantification of Multiple Adulterants in Roasted and Ground Coffee

    Directory of Open Access Journals (Sweden)

    Nádia Reis

    2016-01-01

    Full Text Available This paper proposed the joint use of Fourier Transform Infrared Attenuated Total Reflectance Spectroscopy (FTIR-ATR and Partial Least Square (PLS regression for the simultaneous quantification of four adulterants (coffee husks, spent coffee grounds, barley, and corn in roasted and ground coffee. Roasted coffee samples were intentionally blended with the adulterants, at adulteration levels ranging from 0.5 to 66% w/w. A robust methodology was implemented in which the identification of outliers was carried out. High correlation coefficients (0.99 for both calibration and validation coupled with low degrees of error (0.69% for calibration; 2.00% for validation confirmed that FTIR-ATR can be a valuable analytical tool for quantification of adulteration in roasted and ground coffee. This method is simple, fast, and reliable for the proposed purpose.

  8. Fourier transform infrared-attenuated total reflectance (FTIR-ATR spectroscopy and chemometric techniques for the determination of adulteration in petrodiesel/biodiesel blends

    Directory of Open Access Journals (Sweden)

    Armando Guerrero Peña

    2014-06-01

    Full Text Available We propose an analytical method based on fourier transform infrared-attenuated total reflectance (FTIR-ATR spectroscopy to detect the adulteration of petrodiesel and petrodiesel/palm biodiesel blends with African crude palm oil. The infrared spectral fingerprints from the sample analysis were used to perform principal components analysis (PCA and to construct a prediction model using partial least squares (PLS regression. The PCA results separated the samples into three groups, allowing identification of those subjected to adulteration with palm oil. The obtained model shows a good predictive capacity for determining the concentration of palm oil in petrodiesel/biodiesel blends. Advantages of the proposed method include cost-effectiveness and speed; it is also environmentally friendly.

  9. CO 2 Capture Capacity and Swelling Measurements of Liquid-like Nanoparticle Organic Hybrid Materials via Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy

    KAUST Repository

    Park, Youngjune

    2012-01-12

    Novel nanoparticle organic hybrid materials (NOHMs), which are comprised of organic oligomers or polymers tethered to an inorganic nanosized cores of various sizes, have been synthesized, and their solvating property for CO 2 was investigated using attenuated total reflectance (ATR) Fourier transform infrared (FT-IR) spectroscopy. Simultaneous measurements of CO 2 capture capacity and swelling behaviors of polyetheramine (Jeffamine M-2070) and its corresponding NOHMs (NOHM-I-PE2070) were reported at temperatures of (298, 308, 323 and 353) K and CO 2 pressure conditions ranging from (0 to 5.5) MPa. The polymeric canopy, or polymer bound to the nanoparticle surface, showed significantly less swelling behavior with enhanced or comparable CO 2 capture capacity compared to pure unbound polyetheramine. © 2011 American Chemical Society.

  10. Origin identification of dried distillers grains with solubles using attenuated total reflection Fourier transform mid-infrared spectroscopy after in situ oil extraction.

    Science.gov (United States)

    Vermeulen, Ph; Fernández Pierna, J A; Abbas, O; Dardenne, P; Baeten, V

    2015-12-15

    The ban on using processed animal proteins in feedstuffs led the feed sector to look for other sources of protein. Dried distillers grains with solubles (DDGS) could be considered as an important source in this regard. They are imported into Europe mainly for livestock feed. Identifying their origin is essential when labelling is missing and for feed safety, particularly in a crisis situation resulting from contamination. This study investigated applying attenuated total reflection Fourier transform mid-infrared spectroscopy (ATR-FT-MIR) to the oil fraction extracted from samples in situ in order to identify the origin of DDGS. The use of spectroscopic and chemometric tools enabled the botanical and geographical origins of DDGS, as well as the industrial process used to produce them, to be identified. The models developed during the study provided a classification higher than 95% using an external validation set. PMID:26190596

  11. Fluorescence, CD, attenuated total reflectance (ATR) FTIR, and sup 13 C NMR characterization of the structure and dynamics of synthetic melittin and melittin analogues in lipid environments

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, A.J.; Prendergast, F.G. (Mayo Foundation, Rochester, MN (United States)); Kemple, M.D. (Indiana Univ.-Purdue Univ., Indianapolis (United States)); Brauner, J.W.; Mendelsohn, R. (Rutgers, The State Univ. of New Jersey, Newark (United States))

    1992-02-11

    The structure and dynamics of synthetic melittin (MLT) and MLT analogues bound to monomyristoylphosphatidylcholine micelles, dimyristoylphosphatidylcholine vesicles, and diacylphosphatidylcholine films have been investigated by fluorescence, CD, attenuated total reflectance (ATR) FTIR, and {sup 13}C NMR spectroscopy. All of these methods provide information about peptide secondary structure and/or about the environment of the single tryptophan side chain in these lipid environments. ATR-FTIR data provide additional information about the orientation of helical peptide segments with respect to the bilayer plane. Steady-state fluorescence anisotropy, fluorescence lifetime, and {sup 13}C NMR relaxation data are used in concert to provide quantitative information about the dynamics of a single {sup 13}C{alpha}-labeled glycine incorporated into each of the MLT peptides at position 12. The cumulative structural and dynamic data are consistent with a model wherein the N-terminal {alpha}-helical segment of these peptides is oriented perpendicular to the bilayer plane. Correlation times for the lysolipid-peptide complexes provide evidence for binding of a single peptide monomer per micelle. A model for the membranolytic action of MLT and MLT-like peptides is proposed.

  12. A Catalytic Path for Electrolyte Reduction in Lithium-Ion Cells Revealed by in Situ Attenuated Total Reflection-Fourier Transform Infrared Spectroscopy

    KAUST Repository

    Shi, Feifei

    2015-03-11

    © 2015 American Chemical Society. Although controlling the interfacial chemistry of electrodes in Li-ion batteries (LIBs) is crucial for maintaining the reversibility, electrolyte decomposition has not been fully understood. In this study, electrolyte decomposition on model electrode surfaces (Au and Sn) was investigated by in situ attenuated total reflection-Fourier transform infrared (ATR-FTIR) spectroscopy. Simultaneously obtained ATR-FTIR spectra and cyclic voltammetry measurements show that lithium ethylene dicarbonate and lithium propionate form on the Au electrode at 0.6 V, whereas diethyl 2,5-dioxahexane dicarboxylate and lithium propionate form on the Sn electrode surface at 1.25 V. A noncatalytic reduction path on the Au surface and a catalytic reduction path on the Sn surface are introduced to explain the surface dependence of the overpotential and product selectivity. This represents a new concept for explaining electrolyte reactions on the anode of LIBs. The present investigation shows that catalysis plays a dominant role in the electrolyte decomposition process and has important implications in electrode surface modification and electrolyte recipe selection, which are critical factors for enhancing the efficiency, durability, and reliability of LIBs.

  13. Detection and quantification of soymilk in cow-buffalo milk using Attenuated Total Reflectance Fourier Transform Infrared spectroscopy (ATR-FTIR).

    Science.gov (United States)

    Jaiswal, Pranita; Jha, Shyam Narayan; Borah, Anjan; Gautam, Anuj; Grewal, Manpreet Kaur; Jindal, Gaurav

    2015-02-01

    Milk consumption is steadily increasing, especially in India and China, due to rising income. To bridge the gap between supply and demand, unscrupulous milk vendors add milk-like products from vegetable sources (soymilk) to milk without declaration. A rapid detection technique is required to enforce the safety norms of food regulatory authorities. Fourier Transform Infrared (FTIR) spectroscopy has demonstrated potential as a rapid quality monitoring method and was therefore explored for detection of soymilk in milk. In the present work, spectra of milk, soymilk (SM), and milk adulterated with known quantity of SM were acquired in the wave number range of 4000-500cm(-1) using Attenuated Total Reflectance (ATR)-FTIR. The acquired spectra revealed differences amongst milk, SM and adulterated milk (AM) samples in the wave number range of 1680-1058cm(-1). This region encompasses the absorption frequency of amide-I, amide-II, amide-III, beta-sheet protein, α-tocopherol and Soybean Kunitz Trypsin Inhibitor. Principal component analysis (PCA) showed clustering of samples based on SM concentration at 5% level of significance and thus SM could be detected in milk using ATR-FTIR. The SM was best predicted in the range of 1472-1241cm(-1) using multiple linear regression with coefficient of determination (R(2)) of 0.99 and 0.92 for calibration and validation, respectively. PMID:25172681

  14. Sensing cocaine in saliva with attenuated total reflection infrared (ATR-IR) spectroscopy combined with a one-step extraction method

    Science.gov (United States)

    Hans, Kerstin M.-C.; Gianella, Michele; Sigrist, Markus W.

    2012-03-01

    On-site drug tests have gained importance, e.g., for protecting the society from impaired drivers. Since today's drug tests are majorly only positive/negative, there is a great need for a reliable, portable and preferentially quantitative drug test. In the project IrSens we aim to bridge this gap with the development of an optical sensor platform based on infrared spectroscopy and focus on cocaine detection in saliva. We combine a one-step extraction method, a sample drying technique and infrared attenuated total reflection (ATR) spectroscopy. As a first step we have developed an extraction technique that allows us to extract cocaine from saliva to an almost infrared-transparent solvent and to record ATR spectra with a commercially available Fourier Transform-infrared spectrometer. To the best of our knowledge this is the first time that such a simple and easy-to-use one-step extraction method is used to transfer cocaine from saliva into an organic solvent and detect it quantitatively. With this new method we are able to reach a current limit of detection around 10 μg/ml. This new extraction method could also be applied to waste water monitoring and controlling caffeine content in beverages.

  15. Evaluation of the moisture prediction capability of near-infrared and attenuated total reflectance fourier transform infrared spectroscopy using superdisintegrants as model compounds.

    Science.gov (United States)

    Uppaluri, Sai G; Bompelliwar, Sai K; Johnson, Paul R; Gupta, Mali R; Al-Achi, Antoine; Stagner, William C; Haware, Rahul V

    2014-12-01

    The superdisintegrants (SDs) moisture content measurement by near-infrared (NIR) spectroscopy and attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy has been evaluated against thermogravimetric analysis as a reference method. SDs with varying moisture content were used to build calibration and independent model verification data sets. Calibration models were developed based on the water-specific NIR and ATR-FTIR spectral regions using partial least-square regression methods. Because of the NIR water low molar absorptivity, NIR spectroscopy handled higher moisture content (∼81%, w/w) than ATR-FTIR (∼25%, w/w). A two-way ANOVA test was performed to compare R(2) values obtained from measured and predicted moisture content (5%-25%, w/w) of SDs. No statistically significant difference was observed between the predictability of NIR and ATR-FTIR methods (p = 0.3504). However, the interactions between the two independent variables, SDs, and analytical methods were statistically significant (p = 0.0002), indicating that the predictability of the analytical method is material dependent. Thus, it would be important to recognize this highly dependent material and analytical method interaction when using NIR moisture analysis in process analytical technology to analyze and control critical quality and performance attributes of raw materials during processing with the goal of ensuring final product quality attributes. PMID:25332106

  16. Preparation and transmission characteristics of a mid-infrared attenuated total reflection hollow waveguide based on a stainless steel capillary tube.

    Science.gov (United States)

    Wang, Xu; Guo, Hong; Wang, Lin; Yue, Fangyu; Jing, Chengbin; Chu, Junhao

    2016-08-10

    Stainless steel (SUS) capillary tubes were examined as a category of structural tube for establishing a metallic attenuated total reflection (ATR) GeO2 hollow waveguide. GeO2 films were grown on the inner wall of SUS tubes by different liquid phase deposition (LPD) cycles. Fourier transform infrared (FTIR) spectra, scanning electronic microscope (SEM) image, and transmission loss for a CO2 laser were measured to investigate the effects of the LPD cycles on the transmission behavior of the hollow waveguide samples. The film thickness and surface roughness increase with every LPD cycle. The two LPD cycle sample has a film thickness equivalent to the CO2 laser wavelength, while the surface roughness is acceptable. This sample has the lowest transmission loss (0.27  dB/m) among these samples. The bending loss, output beam profile, and full divergence angle (FDA) were further studied. Higher-order modes are excited by bending the sample, inducing additional loss, decentralized beam profile, and larger FDA. PMID:27534486

  17. Electrochemical oxidation of 2-propanol over platinum and palladium electrodes in alkaline media studied by in situ attenuated total reflection infrared spectroscopy.

    Science.gov (United States)

    Okanishi, Takeou; Katayama, Yu; Ito, Ryota; Muroyama, Hiroki; Matsui, Toshiaki; Eguchi, Koichi

    2016-04-21

    The electrochemical oxidation of 2-propanol over Pt and Pd electrodes was evaluated in alkaline media. Linear sweep voltammograms (LSVs), chronoamperograms (CAs), and simultaneous time-resolved attenuated total reflection infrared (ATR-IR) spectra of both electrodes were obtained in a 0.25 M KOH solution containing 1 M 2-propanol. The onset potential of 2-propanol oxidation for Pt was lower than that for Pd in LSVs while the degree of performance degradation observed for Pd was significantly smaller than that observed for Pt in CAs. The main product of 2-propanol oxidation was acetone over both electrodes and, over Pt only, acetone produced was catalytically oxidized to the enolate ion, which was accumulated on the Pt surface, leading to significant performance degradation. Carbon dioxide and carbonate species (CO3(2-), HCO3(-)) were not observed during 2-propanol oxidation over both electrodes, indicating that the complete oxidation of 2-propanol to CO2 will be a minor reaction. PMID:27009749

  18. Development and validation of an environmentally friendly attenuated total reflectance in the mid-infrared region method for the determination of ethanol content in used engine lubrication oil.

    Science.gov (United States)

    Hatanaka, Rafael Rodrigues; Sequinel, Rodrigo; Gualtieri, Carlos Eduardo; Tercini, Antônio Carlos Bergamaschi; Flumignan, Danilo Luiz; de Oliveira, José Eduardo

    2013-05-15

    Lubricating oils are crucial in the operation of automotive engines because they both reduce friction between moving parts and protect against corrosion. However, the performance of lubricant oil may be affected by contaminants, such as gasoline, diesel, ethanol, water and ethylene glycol. Although there are many standard methods and studies related to the quantification of contaminants in lubricant oil, such as gasoline and diesel oil, to the best of our knowledge, no methods have been reported for the quantification of ethanol in used Otto cycle engine lubrication oils. Therefore, this work aimed at the development and validation of a routine method based on partial least-squares multivariate analysis combined with attenuated total reflectance in the mid-infrared region to quantify ethanol content in used lubrication oil. The method was validated based on its figures of merit (using the net analyte signal) as follows: limit of detection (0.049%), limit of quantification (0.16%), accuracy (root mean square error of prediction=0.089% w/w), repeatability (0.05% w/w), fit (R(2)=0.9997), mean selectivity (0.047), sensitivity (0.011), inverse analytical sensitivity (0.016% w/w(-1)) and signal-to-noise ratio (max: 812.4 and min: 200.9). The results show that the proposed method can be routinely implemented for the quality control of lubricant oils. PMID:23618159

  19. Fourier transform infra-red spectroscopy using an attenuated total reflection probe to distinguish between Japanese larch, pine and citrus plants in healthy and diseased states

    Science.gov (United States)

    Gandolfo, D. S.; Mortimer, H.; Woodhall, J. W.; Boonham, N.

    2016-06-01

    FTIR spectroscopy coupled with an Attenuated Total Reflection (ATR) sampling probe has been demonstrated as a technique for detecting disease in plants. Spectral differences were detected in Japanese Larch (Larix kaempferi) infected with Phytophthora ramorum at 3403 cm-1 and 1730 cm-1, from pine (Pinus spp.) infected with Bursaphelenchus xylophilus at 1070 cm-1, 1425 cm-1, 1621 cm-1 and 3403 cm-1 and from citrus (Citrus spp.) infected with 'Candidatus liberibacter' at 960 cm-1, 1087 cm-1, 1109 cm-1, 1154 cm-1, 1225 cm-1, 1385 cm-1, 1462 cm-1, 1707 cm-1, 2882 cm-1, 2982 cm-1 and 3650 cm-1. A spectral marker in healthy citrus has been identified as Pentanone but is absent from the diseased sample spectra. This agrees with recent work by Aksenov, 2014. Additionally, the spectral signature of Cutin was identified in the spectra of Pinus spp. and Citrus spp. and is consistent with work by Dubis, 1999 and Heredia-Guerrero, 2014.

  20. Simultaneous probing of bulk liquid phase and catalytic gas-liquid-solid interface under working conditions using attenuated total reflection infrared spectroscopy

    International Nuclear Information System (INIS)

    Design and performance of a reactor set-up for attenuated total reflection infrared (ATR-IR) spectroscopy suitable for simultaneous reaction monitoring of bulk liquid and catalytic solid-liquid-gas interfaces under working conditions are presented. As advancement of in situ spectroscopy an operando methodology for gas-liquid-solid reaction monitoring was developed that simultaneously combines catalytic activity and molecular level detection at the catalytically active site of the same sample. Semi-batch reactor conditions are achieved with the analytical set-up by implementing the ATR-IR flow-through cell in a recycle reactor system and integrating a specifically designed gas feeding system coupled with a bubble trap. By the use of only one spectrometer the design of the new ATR-IR reactor cell allows for simultaneous detection of the bulk liquid and the catalytic interface during the working reaction. Holding two internal reflection elements (IRE) the sample compartments of the horizontally movable cell are consecutively flushed with reaction solution and pneumatically actuated, rapid switching of the cell (<1 s) enables to quasi simultaneously follow the heterogeneously catalysed reaction at the catalytic interface on a catalyst-coated IRE and in the bulk liquid on a blank IRE. For a complex heterogeneous reaction, the asymmetric hydrogenation of 2,2,2-trifluoroacetophenone on chirally modified Pt catalyst the elucidation of catalytic activity/enantioselectivity coupled with simultaneous monitoring of the catalytic solid-liquid-gas interface is shown. Both catalytic activity and enantioselectivity are strongly dependent on the experimental conditions. The opportunity to gain improved understanding by coupling measurements of catalytic performance and spectroscopic detection is presented. In addition, the applicability of modulation excitation spectroscopy and phase-sensitive detection are demonstrated

  1. A simple, sensitive and non-destructive technique for characterizing bovine dental enamel erosion: attenuated total reflection Fourier transform infrared spectroscopy.

    Science.gov (United States)

    Kim, In-Hye; Son, Jun Sik; Min, Bong Ki; Kim, Young Kyoung; Kim, Kyo-Han; Kwon, Tae-Yub

    2016-01-01

    Although many techniques are available to assess enamel erosion in vitro, a simple, non-destructive method with sufficient sensitivity for quantifying dental erosion is required. This study characterized the bovine dental enamel erosion induced by various acidic beverages in vitro using attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy. Deionized water (control) and 10 acidic beverages were selected to study erosion, and the pH and neutralizable acidity were measured. Bovine anterior teeth (110) were polished with up to 1 200-grit silicon carbide paper to produce flat enamel surfaces, which were then immersed in 20 mL of the beverages for 30 min at 37 °C. The degree of erosion was evaluated using ATR-FTIR spectroscopy and Vickers' microhardness measurements. The spectra obtained were interpreted in two ways that focused on the ν1, ν3 phosphate contour: the ratio of the height amplitude of ν3 PO4 to that of ν1 PO4 (Method 1) and the shift of the ν3 PO4 peak to a higher wavenumber (Method 2). The percentage changes in microhardness after the erosion treatments were primarily affected by the pH of the immersion media. Regression analyses revealed highly significant correlations between the surface hardness change and the degree of erosion, as detected by ATR-FTIR spectroscopy (P<0.001). Method 1 was the most sensitive to these changes, followed by surface hardness change measurements and Method 2. This study suggests that ATR-FTIR spectroscopy is potentially advantageous over the microhardness test as a simple, non-destructive, sensitive technique for the quantification of enamel erosion. PMID:27025266

  2. Orientation and Lipid-Peptide Interactions of Gramicidin A in Lipid Membranes: Polarized Attenuated Total Reflection Infrared Spectroscopy and Spin-Label Electron Spin Resonance

    Science.gov (United States)

    Kóta, Zoltán; Páli, Tibor; Marsh, Derek

    2004-01-01

    Gramicidin A was incorporated at a peptide/lipid ratio of 1:10 mol/mol in aligned bilayers of dimyristoyl phosphatidylcholine (DMPC), phosphatidylserine (DMPS), phosphatidylglycerol (DMPG), and phosphatidylethanolamine (DMPE), from trifluoroethanol. Orientations of the peptide and lipid chains were determined by polarized attenuated total reflection infrared spectroscopy. Lipid-peptide interactions with gramicidin A in DMPC bilayers were studied with different spin-labeled lipid species by using electron spin resonance spectroscopy. In DMPC membranes, the orientation of the lipid chains is comparable to that in the absence of peptide, in both gel and fluid phases. In gel-phase DMPC, the effective tilt of the peptide exceeds that of the lipid chains, but in the fluid phase both are similar. For gramicidin A in DMPS, DMPG, and DMPE, the degree of orientation of the peptide and lipid chains is less than in DMPC. In the fluid phase of DMPS, DMPG, and DMPE, gramicidin A is also less well oriented than are the lipid chains. In DMPE especially, gramicidin A is largely disordered. In DMPC membranes, three to four lipids per monomer experience direct motional restriction on interaction with gramicidin A. This is approximately half the number of lipids expected to contact the intramembranous perimeter of the gramicidin A monomer. A selectivity for certain negatively charged lipids is found in the interaction with gramicidin A in DMPC. These results are discussed in terms of the integration of gramicidin A channels in lipid bilayers, and of the interactions of lipids with integral membrane proteins. PMID:14990479

  3. A simple, sensitive and non-destructive technique for characterizing bovine dental enamel erosion:attenuated total reflection Fourier transform infrared spectroscopy

    Institute of Scientific and Technical Information of China (English)

    In-Hye Kim; Jun Sik Son; Bong Ki Min; Young Kyoung Kim; Kyo-Han Kim; Tae-Yub Kwon

    2016-01-01

    Although many techniques are available to assess enamel erosion in vitro, a simple, non-destructive method with sufficient sensitivity for quantifying dental erosion is required. This study characterized the bovine dental enamel erosion induced by various acidic beverages in vitro using attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy. Deionized water (control) and 10 acidic beverages were selected to study erosion, and the pH and neutralizable acidity were measured. Bovine anterior teeth (110) were polished with up to 1 200-grit silicon carbide paper to produce flat enamel surfaces, which were then immersed in 20 mL of the beverages for 30 min at 37 °C. The degree of erosion was evaluated using ATR-FTIR spectroscopy and Vickers’ microhardness measurements. The spectra obtained were interpreted in two ways that focused on the ν1, ν3 phosphate contour: the ratio of the height amplitude of ν3 PO4 to that of ν1 PO4 (Method 1) and the shift of the ν3 PO4 peak to a higher wavenumber (Method 2). The percentage changes in microhardness after the erosion treatments were primarily affected by the pH of the immersion media. Regression analyses revealed highly significant correlations between the surface hardness change and the degree of erosion, as detected by ATR-FTIR spectroscopy (Po0.001). Method 1 was the most sensitive to these changes, followed by surface hardness change measurements and Method 2. This study suggests that ATRFTIR spectroscopy is potentially advantageous over the microhardness test as a simple, non-destructive, sensitive technique for the quantification of enamel erosion.

  4. Attenuated Total Reflection Fourier Transform Infrared Spectroscopy (ATR FT-IR) Mapping Coupled with Multivariate Curve Resolution (MCR) for Studying the Miscibility of Chlorobutyl Rubber/Polyamide-12 Blends.

    Science.gov (United States)

    Tang, Yongjiao; Jing, Nan; Zhang, Pudun

    2015-11-01

    A series of chlorobutyl rubber/polyamide-12 (CIIR/PA-12) blends compatibilized by different amounts of maleic anhydride (MAH) grafted polypropylene (PP-g-MAH) were investigated by attenuated total reflection Fourier transform infrared spectroscopy (ATR FT-IR) mapping. Multivariate curve resolution (MCR) was used to process the FT-IR images. Both the spectra of pure components in the blends and their concentration distributions in a micro-region were acquired. Our results demonstrated that the blend with 15 parts per hundred rubber PP-g-MAH showed the best miscibility. An amide interphase and an imide interphase were inferred by analyzing the spectra of MCR component 3 of the blends with and without PP-g-MAH, respectively. Correspondingly, two different compatibilizing mechanisms were proposed for these blends. PMID:26647055

  5. Label-Free Determination of Protein Binding in Aqueous Solution using Overlayer Enhanced Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy (OE-ATR-FTIR)

    Science.gov (United States)

    Ruthenburg, Travis; Aweda, Tolulope; Park, Simon; Meares, Claude; Land, Donald

    2009-03-01

    Protein binding/affinity studies are often performed using Surface Plasmon Resonance techniques that don't produce much spectral information. Measurement of protein binding affinity using FTIR is traditionally performed using high protein concentration or deuterated solvent. By immobilizing a protein near the surface of a gold-coated germanium internal reflection element interactions can be measured between an immobilized protein and free proteins or small molecules in aqueous solution. By monitoring the on and off rates of these interactions, the dissociation constant for the system can be determined. The dissociation constant for the molecule Yttrium-DOTA binding to the antibody 2D12.5 system was determined to be 100nM. Results will also be presented from our measurements of Bovine Serum Albumin (BSA) binding to anti-BSA.

  6. Application of Attenuated Total Reflectance-Fourier Transformed Infrared (ATR-FTIR) Spectroscopy To Determine the Chlorogenic Acid Isomer Profile and Antioxidant Capacity of Coffee Beans.

    Science.gov (United States)

    Liang, Ningjian; Lu, Xiaonan; Hu, Yaxi; Kitts, David D

    2016-01-27

    The chlorogenic acid isomer profile and antioxidant activity of both green and roasted coffee beans are reported herein using ATR-FTIR spectroscopy combined with chemometric analyses. High-performance liquid chromatography (HPLC) quantified different chlorogenic acid isomer contents for reference, whereas ORAC, ABTS, and DPPH were used to determine the antioxidant activity of the same coffee bean extracts. FTIR spectral data and reference data of 42 coffee bean samples were processed to build optimized PLSR models, and 18 samples were used for external validation of constructed PLSR models. In total, six PLSR models were constructed for six chlorogenic acid isomers to predict content, with three PLSR models constructed to forecast the free radical scavenging activities, obtained using different chemical assays. In conclusion, FTIR spectroscopy, coupled with PLSR, serves as a reliable, nondestructive, and rapid analytical method to quantify chlorogenic acids and to assess different free radical-scavenging capacities in coffee beans. PMID:26725502

  7. Identification of natural dyes on laboratory-dyed wool and ancient wool, silk, and cotton fibers using attenuated total reflection (ATR) Fourier transform infrared (FT-IR) spectroscopy and Fourier transform Raman spectroscopy.

    Science.gov (United States)

    Bruni, Silvia; De Luca, Eleonora; Guglielmi, Vittoria; Pozzi, Federica

    2011-09-01

    Attenuated total reflection (ATR) infrared and Fourier transform (FT) Raman spectra were obtained from wool threads dyed in the laboratory with natural dyes used in antiquity, following a procedure similar to ancient methods for dyeing wool. The ATR spectra were primarily dominated by the signals of the wool, making it difficult to identify the dye on the fibers only by visual inspection of the infrared spectrum. However, the Raman spectra showed more significant characteristics attributable to the dyes as previously studied in the literature on modern synthetic dyes. A library-search method was thus applied to the second derivatives of both the ATR and Raman spectra to verify the possibility of identifying the dye. Two libraries were constructed, one consisting of the ATR spectra of undyed wool (raw, washed, and mordanted) and the transmission spectra of pure dyes and the other consisting of the Raman spectra of undyed wool and of pure dyes. Correlation and first-derivative correlation search algorithms were used. The results presented here suggest that the two types of spectroscopy are complementary in this kind of work, allowing the almost complete identification of historic dyes on wool. In fact, through the combined use of the two searches, most dyes were identified with a good index of similarity and within the first five hits. Only for annatto was identification totally impossible using either technique. Subsequently the same method was applied to wool, silk, and cotton threads taken from ancient Caucasian and Chinese textiles. PMID:21929856

  8. A study of surface film formation on LiNi0.8Co0.15Al0.05O2 cathodes u sing attenuated total reflection infrared spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Song, S.-W.; Zhuang, G.V.; Ross Jr., P.N.

    2004-01-19

    The surface films formed on commercial LiNi0.8Co0.15Al0.05O2 cathodes (ATD Gen2) charged from 3.75V to 4.2V vs. Li/Li+ in EC:DEC - 1M LiPF6 were analyzed using ex-situ Fourier transform infrared spectroscopy (FTIR) with the attenuated total reflection (ATR) technique. A surface layer of Li2CO3 is present on the virgin cathode, probably from reaction of the active material with air during the cathode preparation procedure. The Li2CO3 layer disappeared even after soaking in the electrolyte, indicating that the layer dissolved into the electrolyte possibly even before potential cycling of the electrode. IR features only from the binder (PVdF) and a trace of polyamide from the Al current collector were observed on the surfaces of cathodes charged to below 4.2 V, i.e., no surface species from electrolyte oxidation. Some new IR features were, however, found on the cathode charged to 4.2 V and higher. An electrolyte oxidation product was observed that appeared to contain dicarbonyl anhydride and (poly)ester functionalities. The reaction appears to be an indirect electrochemical oxidation with overcharging (removal of > 0.6 Li ions) destabilizing oxygen in the oxide lattice resulting in oxygen transfer to the solvent molecules.

  9. Timing the total reflection of light

    International Nuclear Information System (INIS)

    We have identified for the first time the absolute delay at total reflection, envisioned by Newton. We show that there are in fact two divergent Wigner delays, depending on the polarisation of the incident light. These measurements give a new insight on the passage from total reflection to refraction

  10. Direct determination of sorbitol and sodium glutamate by attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR) in the thermostabilizer employed in the production of yellow-fever vaccine.

    Science.gov (United States)

    de Castro, Eduardo da S G; Cassella, Ricardo J

    2016-05-15

    Reference methods for quality control of vaccines usually require treatment of the samples before analysis. These procedures are expensive, time-consuming, unhealthy and require careful manipulation of the sample, making them a potential source of analytical errors. This work proposes a novel method for the quality control of thermostabilizer samples of the yellow fever vaccine employing attenuated total reflectance Fourier transform infrared spectrometry (ATR-FTIR). The main advantage of the proposed method is the possibility of direct determination of the analytes (sodium glutamate and sorbitol) without any pretreatment of the samples. Operational parameters of the FTIR technique, such as the number of accumulated scans and nominal resolution, were evaluated. The best conditions for sodium glutamate were achieved when 64 scans were accumulated using a nominal resolution of 4 cm(-1). The measurements for sodium glutamate were performed at 1347 cm(-1) (baseline correction between 1322 and 1369 cm(-1)). In the case of sorbitol, the measurements were done at 890cm(-1) (baseline correction between 825 and 910 cm(-1)) using a nominal resolution of 2 cm(-1) with 32 accumulated scans. In both cases, the quantitative variable was the band height. Recovery tests were performed in order to evaluate the accuracy of the method and recovery percentages in the range 93-106% were obtained. Also, the methods were compared with reference methods and no statistical differences were observed. The limits of detection and quantification for sodium glutamate were 0.20 and 0.62% (m/v), respectively, whereas for sorbitol they were 1 and 3.3% (m/v), respectively. PMID:26992492

  11. Quantitative determination of two polymorphic forms of imatinib mesylate in a drug substance and tablet formulation by X-ray powder diffraction, differential scanning calorimetry and attenuated total reflectance Fourier transform infrared spectroscopy.

    Science.gov (United States)

    Bellur Atici, Esen; Karlığa, Bekir

    2015-10-10

    Imatinib has been identified as a tyrosine kinase inhibitor that selectively inhibits the Abl tyrosine kinases, including Bcr-Abl. The active substance used in drug product is the mesylate salt form of imatinib, a phenylaminopyrimidine derivative and chemically named as N-(3-(4-(pyridin-3-yl) pyrimidin-2-ylamino)-4-methylphenyl)-4-((4-methylpiperazin-1-yl) methyl)-benzamide methanesulfonic acid salt. It exhibits many polymorphic forms and most stable and commercialized polymorphs are known as α and β forms. Molecules in α and β polymorphic forms exhibit significant conformational differences due to their different intra- and intermolecular interactions, which stabilize their molecular conformations and affect their physicochemical properties such as bulk density, melting point, solubility, stability, and processability. The manufacturing process of a drug tablet included granulation, compression, coating, and drying may cause polymorphic conversions. Therefore, polymorphic content of the drug substance should be controlled during quality control and stability testing. Attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy, differential scanning calorimetry (DSC), and powder X-ray diffraction (PXRD) methods were evaluated for determination of the polymorphic content of the drug substance and drug product; and PXRD was the most accurate technique and selected as preferred method and validated. Prior to development of a quantification method, pure α and β polymorphs were characterized and used throughout the method development and validation studies. Mixtures with different ratios of α and β forms were scanned using X-ray diffractometer with a scan rate of 0.250°/min over an angular range of 19.5-21.0° 2θ and the peak heights for characteristic peak of β form at 20.5 ± 0.2° 2θ diffraction angle were used to generate a calibration curve. The detection limit of β polymorph in α form imatinib mesylate tablets was found as 4% and

  12. Total internal reflection laser tools and methods

    Energy Technology Data Exchange (ETDEWEB)

    Zediker, Mark S.; Faircloth, Brian O.; Kolachalam, Sharath K.; Grubb, Daryl L.

    2016-02-02

    There is provided high power laser tools and laser heads that utilize total internal reflection ("TIR") structures to direct the laser beam along a laser beam path within the TIR structure. The TIR structures may be a TIR prism having its hypotenuse as a TIR surface.

  13. Total reflection X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    In the past few years, total reflection X-ray flourescence analysis (TXRF) has found an increasing number of assignments and applications. Experience of trace element analysis using TXRF and examples of applications are already widespread. Therefore, users of TXRF had the opportunity of an intensive exchange of their experience at the 1st workshop on total reflection X-ray fluorescence analysis which took place on May 27th and 28th 1986 at the GKSS Research Centre at Geesthacht. In a series of lectures and discussions dealing with the analytical principle itself, sample preparation techniques and applications as well as comuter programs for spectrum evaluation, the present state of development and the range of applications were outlined. 3 studies out of a total of 14 were included separately in the INIS and ENERGY databases. With 61 figs., 12 tabs

  14. Total internal reflection tomography of small objects

    International Nuclear Information System (INIS)

    The multiple signal classification (MUSIC) imaging method is applied to determine the locations of a collection of small anisotropic spherical scatterers in the framework of the total internal reflection tomography. Multiple scattering between scatterers is considered and the inverse scattering problem is nonlinear, which, however, is solved by the proposed fast analytical approach where no associated forward problem is iteratively evaluated. The paper also discusses the role of the polarization of incidence waves, the incidence angle, the separation of scatterers from the surface of the substrate, and the level of noise on the resolution of imaging.

  15. DEVELOPEMENT OF A LIGHT ATTENUATOR BASED ON GLASSY REFLECTIONS

    Directory of Open Access Journals (Sweden)

    K. Ferria

    2015-07-01

    Full Text Available The light intensity control of a luminous source is a very important operation in many optical applications. Several types of light attenuator exploiting different optical phenomena like diffraction, absorption, and reflection exist and they differ principally in the maximum attenuation rate, the control range, the sensitivity and the spectral band. In the presented work, we have developed and designed a light attenuator based on the progressive decrease of the transmitted light intensity, when it undergoes multiple vitreous reflections across eight plates glasses arranged in a roof shape. Several tests were carried out using a laser light as a source. We have shown that the attenuation rate can be controlled by the choice of the incidence angle on the glasses slides, in addition we have confirmed, for the case of perpendicular polarization of the laser light, that the attenuation obeys to a linear function. The obtained results are very close to those predicted theoretically.

  16. Study on Detection Methods of Interstitial Fluid Glucose Concentration Based on Infrared Attenuated Total Reflection%基于红外ATR光谱的组织液中葡萄糖信息检测方法研究

    Institute of Scientific and Technical Information of China (English)

    孙长月; 曹玉珍; 余松林; 于海霞; 徐可欣; 栗大超

    2014-01-01

    Measuring the glucose concentrations in the interstitial fluid is currently the main method to achieve the continuous blood glucose monitoring .The MIR-ATR(Mid-infrared ,Attenuated Total Reflection)Spectroscopy has prominent advantage on the analysis of small biological molecule for composition information like the glucose ,but it is still an unresolved problem that how to detect the subcutaneous glucose concentration by using the MIR-ATR Spectroscopy .In the present paper ,we carry out the experiment based on MIR-ATR for the detection of subcutaneous glucose information on both the natural state and the pene-tration state based on the theoryanalysis of MIR penetration depth .Firstly ,collect spectral data of the subcutaneous glucose con-centration of human finger on the natural state were collected as the light shined the skin directly ,and it was discussed whether the MIR can penetrate the skin to get the information of subcutaneous glucose .On this basis ,collect spectral data of the subcu-taneous glucose concentration of human finger at the penetration state were collected when the Interstitial fluid is permeated to the surface layer by using low-frequency ultrasound and vacuum ,then it analyzed that whether it can detect the glucose-specific information or not .As the two-dimensional correlation spectroscopy has high resolution and good versatility ,it is widely used to analyze the inter-molecular reaction and judge the absorption peaks information in many fields including the M IR spectroscopy field ,so we choose the Two-dimensional correlation spectroscopy to analyze the information of subcutaneous glucose concentra-tion at the natural state and the penetration state .The experiment result shows that the MIR-ATR spectroscopy can’t be applied in the detection of subcutaneous glucose concentrationdirectly ,and it is a promising direction to make the Interstitial fluid perme-ated to the surface layer by the physical methods or chemical methods .%通过测量

  17. 基于红外ATR光谱的组织液中葡萄糖信息检测方法研究%Study on Detection Methods of Interstitial Fluid Glucose Concentration Based on Infrared Attenuated Total Reflection

    Institute of Scientific and Technical Information of China (English)

    孙长月; 曹玉珍; 余松林; 于海霞; 徐可欣; 栗大超

    2014-01-01

    Measuring the glucose concentrations in the interstitial fluid is currently the main method to achieve the continuous blood glucose monitoring .The MIR-ATR(Mid-infrared ,Attenuated Total Reflection)Spectroscopy has prominent advantage on the analysis of small biological molecule for composition information like the glucose ,but it is still an unresolved problem that how to detect the subcutaneous glucose concentration by using the MIR-ATR Spectroscopy .In the present paper ,we carry out the experiment based on MIR-ATR for the detection of subcutaneous glucose information on both the natural state and the pene-tration state based on the theoryanalysis of MIR penetration depth .Firstly ,collect spectral data of the subcutaneous glucose con-centration of human finger on the natural state were collected as the light shined the skin directly ,and it was discussed whether the MIR can penetrate the skin to get the information of subcutaneous glucose .On this basis ,collect spectral data of the subcu-taneous glucose concentration of human finger at the penetration state were collected when the Interstitial fluid is permeated to the surface layer by using low-frequency ultrasound and vacuum ,then it analyzed that whether it can detect the glucose-specific information or not .As the two-dimensional correlation spectroscopy has high resolution and good versatility ,it is widely used to analyze the inter-molecular reaction and judge the absorption peaks information in many fields including the M IR spectroscopy field ,so we choose the Two-dimensional correlation spectroscopy to analyze the information of subcutaneous glucose concentra-tion at the natural state and the penetration state .The experiment result shows that the MIR-ATR spectroscopy can’t be applied in the detection of subcutaneous glucose concentrationdirectly ,and it is a promising direction to make the Interstitial fluid perme-ated to the surface layer by the physical methods or chemical methods .%通过测量

  18. Importance of Attenuating Quadriceps Activation Deficits after Total Knee Arthroplasty

    OpenAIRE

    Thomas, Abbey C.; Jennifer E Stevens-Lapsley

    2012-01-01

    Total knee arthroplasty (TKA) is associated with persistent quadriceps dysfunction. Since quadriceps dysfunction impairs functional performance, minimizing quadriceps dysfunction by attenuating central activation deficits early after surgery may improve function later in life. Rehabilitation strategies incorporating neuromuscular electrical stimulation and early, aggressive quadriceps strengthening may prove beneficial. Further, surgical approaches such as minimally invasive TKA may minimize ...

  19. Attenuation (1/Q) estimation in reflection seismic records

    Science.gov (United States)

    Raji, Wasiu; Rietbrock, Andreas

    2013-08-01

    Despite its numerous potential applications, the lack of a reliable method for determining attenuation (1/Q) in seismic data is an issue when utilizing attenuation for hydrocarbon exploration. In this paper, a new method for measuring attenuation in reflection seismic data is presented. The inversion process involves two key stages: computation of the centroid frequency for the individual signal using a variable window length and fast Fourier transform; and estimation of the difference in the centroid frequency and travel time for paired incident and transmitted signals. The new method introduces a shape factor and a constant which allows several spectral shapes to be used to represent a real seismic signal without altering the mathematical model. Application of the new method to synthetic data shows that it can provide reliable estimates of Q using any of the spectral shapes commonly assumed for real seismic signals. Tested against two published methods of Q measurement, the new method shows less sensitivity to interference from noise and change of frequency bandwidth. The method is also applied to a 3D data set from the Gullfaks field, North Sea, Norway. The trace length is divided into four intervals: AB, BC, CD, and DE. Results show that interval AB has the lowest 1/Q value, and that interval BC has the highest 1/Q value. The values of 1/Q measured in the CDP stack using the new method are consistent with those measured using the classical spectral ratio method.

  20. Plasmonically amplified bioassay - Total internal reflection fluorescence vs. epifluorescence geometry.

    Science.gov (United States)

    Hageneder, Simone; Bauch, Martin; Dostalek, Jakub

    2016-08-15

    This paper investigates plasmonic amplification in two commonly used optical configurations for fluorescence readout of bioassays - epifluorescence (EPF) and total internal reflection fluorescence (TIRF). The plasmonic amplification in the EPF configuration was implemented by using crossed gold diffraction grating and Kretschmann geometry of attenuated total reflection method (ATR) was employed in the TIRF configuration. Identical assay, surface architecture for analyte capture, and optics for the excitation, collection and detection of emitted fluorescence light intensity were used in both TIRF and EPF configurations. Simulations predict that the crossed gold diffraction grating (EPF) can amplify the fluorescence signal by a factor of 10(2) by the combination of surface plasmon-enhanced excitation and directional surface plasmon-coupled emission in the red part of spectrum. This factor is about order of magnitude higher than that predicted for the Kretschmann geometry (TIRF) which only took advantage of the surface plasmon-enhanced excitation. When applied for the readout of sandwich interleukin 6 (IL-6) immunoassay, the plasmonically amplified EPF geometry designed for Alexa Fluor 647 labels offered 4-times higher fluorescence signal intensity compared to TIRF. Interestingly, both geometries allowed reaching the same detection limit of 0.4pM despite of the difference in the fluorescence signal enhancement. This is attributed to inherently lower background of fluorescence signal for TIRF geometry compared to that for EPF which compensates for the weaker fluorescence signal enhancement. The analysis of the inflammation biomarker IL-6 in serum at medically relevant concentrations and the utilization of plasmonic amplification for the fluorescence measurement of kinetics of surface affinity reactions are demonstrated for both EPF and TIRF readout. PMID:27260457

  1. Total Internal Reflection of Orbital Angular Momentum Beams

    OpenAIRE

    Loffler W.; Hermosa N.; Aiello A.; Woerdman J.P.

    2012-01-01

    We investigate how beams with orbital angular momentum (OAM) behave under total internal reflection. This is studied in two complementary experiments: In the first experiment, we study geometric shifts of OAM beams upon total internal reflection (Goos-H\\"anchen and Imbert-Fedorov shifts, for each the spatial and angular variant), and in the second experiment we determine changes in the OAM mode spectrum of a beam, again upon total internal reflection. As a result we find that in the first cas...

  2. Seismic random noise attenuation using shearlet and total generalized variation

    Science.gov (United States)

    Kong, Dehui; Peng, Zhenming

    2015-12-01

    Seismic denoising from a corrupted observation is an important part of seismic data processing which improves the signal-to-noise ratio (SNR) and resolution. In this paper, we present an effective denoising method to attenuate seismic random noise. The method takes advantage of shearlet and total generalized variation (TGV) regularization. Different regularity levels of TGV improve the quality of the final result by suppressing Gibbs artifacts caused by the shearlet. The problem is formulated as mixed constraints in a convex optimization. A Bregman algorithm is proposed to solve the proposed model. Extensive experiments based on one synthetic datum and two post-stack field data are done to compare performance. The results demonstrate that the proposed method provides superior effectiveness and preserve the structure better.

  3. Coherent resonant scattering during a total external reflection

    International Nuclear Information System (INIS)

    We present the experimental results on coherent nuclear reflection from Moessbauer medium under the condition of total external reflection (TER). In order to obtain information about angle- and time- dependent reflectivity of the medium for both coherent and non-coherent radiation, we used both grazing incidence Moessbauer spectroscopy (GIMS) and synchrotron radiation (SR) to record the energy and time-domain spectra for the common samples. Multilayer samples with Fe-Cr alloy (60% Fe) were used as reflecting Moessbauer medium. (authors)

  4. Multiple attenuation to reflection seismic data using Radon filter and Wave Equation Multiple Rejection (WEMR) method

    Energy Technology Data Exchange (ETDEWEB)

    Erlangga, Mokhammad Puput [Geophysical Engineering, Institut Teknologi Bandung, Ganesha Street no.10 Basic Science B Buliding fl.2-3 Bandung, 40132, West Java Indonesia puput.erlangga@gmail.com (Indonesia)

    2015-04-16

    Separation between signal and noise, incoherent or coherent, is important in seismic data processing. Although we have processed the seismic data, the coherent noise is still mixing with the primary signal. Multiple reflections are a kind of coherent noise. In this research, we processed seismic data to attenuate multiple reflections in the both synthetic and real seismic data of Mentawai. There are several methods to attenuate multiple reflection, one of them is Radon filter method that discriminates between primary reflection and multiple reflection in the τ-p domain based on move out difference between primary reflection and multiple reflection. However, in case where the move out difference is too small, the Radon filter method is not enough to attenuate the multiple reflections. The Radon filter also produces the artifacts on the gathers data. Except the Radon filter method, we also use the Wave Equation Multiple Elimination (WEMR) method to attenuate the long period multiple reflection. The WEMR method can attenuate the long period multiple reflection based on wave equation inversion. Refer to the inversion of wave equation and the magnitude of the seismic wave amplitude that observed on the free surface, we get the water bottom reflectivity which is used to eliminate the multiple reflections. The WEMR method does not depend on the move out difference to attenuate the long period multiple reflection. Therefore, the WEMR method can be applied to the seismic data which has small move out difference as the Mentawai seismic data. The small move out difference on the Mentawai seismic data is caused by the restrictiveness of far offset, which is only 705 meter. We compared the real free multiple stacking data after processing with Radon filter and WEMR process. The conclusion is the WEMR method can more attenuate the long period multiple reflection than the Radon filter method on the real (Mentawai) seismic data.

  5. Nondestructive Determination of the Age of 20th-Century Oil-Binder Ink Prints Using Attenuated Total Reflection Fourier Transform Infrared Spectroscopy (ATR FT-IR): A Case Study with Postage Stamps from the Łódź Ghetto.

    Science.gov (United States)

    Bower, Nathan W; Blanchet, Conor J K; Epstein, Michael S

    2016-01-01

    The ability to determine the production date for a painting or print would be of great benefit in the forensic detection of fakes and forgeries as well as in art history and conservation. Changes in the pigments used at different times have been invaluable in detecting incongruities that suggest fraud, but relatively little work has been published that uses the chemical changes in oil binders as they dry to determine when an ink print or an oil painting was made. Using attenuated total reflectance-Fourier transform infrared (ATR FT-IR) spectroscopy and samples with known dates, we calibrate the drying of oil binders in inks and paints and cross-validate the paints with pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS). We apply the ink calibration to a case study involving the age determination of possible philatelic counterfeits from a World War II Jewish Ghetto in Occupied Poland, obtaining a date of 1946 ± 6 (1 s, n = 9) for the genuine stamps, and 1963 ± 16 (1 s, n = 19) for the various reproductions. PMID:26767642

  6. Total internal reflection of orbital angular momentum beams

    International Nuclear Information System (INIS)

    We investigate how beams with orbital angular momentum (OAM) behave under total internal reflection. This is studied in two complementary experiments: in the first experiment, we study geometric shifts of OAM beams upon total internal reflection (Goos–Hänchen and Imbert–Fedorov shifts, for each the spatial and angular variant), and in the second experiment we determine changes in the OAM mode spectrum of a beam, again upon total internal reflection. As a result we find that, in the first case, the shifts are independent of OAM and beam focusing, while in the second case, modifications in the OAM spectrum occur which depend on the input OAM mode as well as on the beam focusing. This is investigated by experiment and theory. We also show how the two methods, beam shifts on the one hand, and OAM spectrum changes on the other, are related theoretically. (paper)

  7. Total Internal Reflection of Orbital Angular Momentum Beams

    CERN Document Server

    Löffler, W; Aiello, Andrea; Woerdman, J P

    2012-01-01

    We investigate how beams with orbital angular momentum (OAM) behave under total internal reflection. This is studied in two complementary experiments: In the first experiment, we study geometric shifts of OAM beams upon total internal reflection (Goos-H\\"anchen and Imbert-Fedorov shifts, for each the spatial and angular variant), and in the second experiment we determine changes in the OAM mode spectrum of a beam, again upon total internal reflection. As a result we find that in the first case, the shifts are independent of OAM and beam focussing, while in the second case, modifications in the OAM spectrum occur which depend on the input OAM mode as well as on the beam focussing. This is investigated by experiment and theory. We also show how the two methods, beam shifts on the one hand, and OAM spectrum changes on the other, are related theoretically.

  8. Investigation of total reflection X-ray fluorescence analysis technique

    International Nuclear Information System (INIS)

    Total-Reflection X-ray Fluorescence spectrometry (TRXF) is known for its high sensitivity down to Pg-level or sub ppb level, respectively. Therefore the spectrometry is considered as a most competitive tool in the application of trace element analysis. The technique of TRXF was investigated in the laboratory. But small isotope X-γ source is chosen as an exciting source instead of general X-ray tube. From the primitive experiment the conclusion proved that the condition of total reflection can be built and the analysis sensitivity of TRXF is higher than that of normal x-ray analysis

  9. Versatile frustrated-total-reflection polarizer for the infrared

    Energy Technology Data Exchange (ETDEWEB)

    Lees, D.; Baumeister, P.

    1979-02-01

    A new type of thin-film polarizing beam splitter based on the frustrated-total reflection effect is described. The device may be designed to transmit either p or s linearly light. A polarization ratio on the order of 1000:1 is expected.

  10. Versatile frustrated-total-reflection polarizer for the infrared

    International Nuclear Information System (INIS)

    A new type of thin-film polarizing beam splitter based on the frustrated-total reflection effect is described. The device may be designed to transmit either p or s linearly light. A polarization ratio on the order of 1000:1 is expected

  11. Novel perspectives for the application of total internal reflection microscopy

    CERN Document Server

    Volpe, Giovanni; Helden, Laurent; Bechinger, Clemens

    2009-01-01

    Total Internal Reflection Microscopy (TIRM) is a sensitive non-invasive technique to measure the interaction potentials between a colloidal particle and a wall with femtonewton resolution. The equilibrium distribution of the particle-wall separation distance z is sampled monitoring the intensity I scattered by the Brownian particle under evanescent illumination. Central to the data analysis is the knowledge of the relation between I and the corresponding z, which typically must be known a priori. This poses considerable constraints to the experimental conditions where TIRM can be applied (short penetration depth of the evanescent wave, transparent surfaces). Here, we introduce a method to experimentally determine I(z) by relying only on the distance-dependent particle-wall hydrodynamic interactions. We demonstrate that this method largely extends the range of conditions accessible with TIRM, and even allows measurements on highly reflecting gold surfaces where multiple reflections lead to a complex I(z).

  12. Breakthroughs in Photonics 2014: Relaxed Total Internal Reflection

    CERN Document Server

    Jahani, Saman

    2015-01-01

    Total internal reflection (TIR) is a ubiquitous phenomenon used in photonic devices ranging from waveguides and resonators to lasers and optical sensors. Controlling this phenomenon and light confinement are keys to the future integration of nanoelectronics and nanophotonics on the same silicon platform. We introduced the concept of relaxed total internal reflection in 2014 to control evanescent waves generated during TIR. These unchecked evanescent waves are the fundamental reason photonic devices are inevitably diffraction-limited and cannot be miniaturized. Our key design concept is the engineered anisotropy of the medium into which the evanescent wave extends thus allowing for skin depth engineering without any metallic components. In this article, we give an overview of our approach and compare it to key classes of photonic devices such as plasmonic waveguides, photonic crystal waveguides and slot waveguides. We show how our work can overcome a long standing issue in photonics nanoscale light confinement...

  13. Total Reflection X Ray Fluorescence: an approach to nano analysis

    International Nuclear Information System (INIS)

    Within the last decade, Total Reflection X Ray Fluorescence (TXRF) has become an extremely powerful method of element analysis. It allows nanoanalytical investigations in three different ways: (i) use of minute sample amounts of only some 100 nanograms, (i i) determination of extreme traces down to nanograms per liter and (i i i) depth profiling of near surface layers of only 10 nanometer thickness. The basic principles of TXRF are described and examples of applications are demonstrated

  14. Total photon attenuation coefficients in some rare earth elements using selective excitation method

    International Nuclear Information System (INIS)

    The total mass attenuation coefficients were measured in the elements La, Nd, Sm, Gd and Dy belonging to rare earth region in the energy range 30–55 keV by employing the selective excitation method. This method facilitates selection of excitation energies near the K edge. The present experimental results were compared with the theoretical values due to Chantler and XCOM. - Highlights: • Total mass attenuation coefficients were measured for La, Nd, Sm, Gd and Dy. • Measured energy is 30–53 keV. • Accurate knowledge of attenuation coefficients is useful for shielding purpose. • Deviations at energies above K edge support the EXAFS effect

  15. Comment on 'Photonic tunneling time in frustrated total internal reflection'

    International Nuclear Information System (INIS)

    This is a comment on Stahlhofen's paper [Phys. Rev. A 62, 012112 (2000)]. It is shown by stationary-phase theory that the Goos-Haenchen shift in frustrated total internal reflection (FTIR) is not independent of the group delay (or phase time in the literature). The group delay involves the contribution of Goos-Haenchen shift and is always larger than zero in FTIR. It is also shown that the group delay in the two-dimensional (2D) optical FTIR can be written in the same form as that of the group delay in the 1D quantum tunneling in the sense that the group delay is the derivative of the total phase shift with respect to the angular frequency

  16. MEASUREMENTS OF RAIN DROP SIZE DISTRBUTION FROM RADAR REFLECTIVITY AND ASSOCIATED RAIN ATTENUATION OF RADIO WAVES

    Directory of Open Access Journals (Sweden)

    A. B. Bhattacharya,

    2011-05-01

    Full Text Available Radar measurements of rainfall at different climatological conditions have been taken into account emphasizing rain rate and associated radar reflectivity. It is observed from the analysis that thereflectivity measurement is being consistent at high rain intensities. From the knowledge of radar reflectivity, the rain drop size distribution is examined. The most probable drop size diameter and rain rate have been calculated wherefrom it appears that the most probable rain drop size vary exponentially with radar reflectivity and also with rain rate. The theoretical model implemented by using the measured rain drop sizes over the tropical sites also show similar kind of variation. For estimating rain attenuation two important parameters, viz., the point rainfall rates and the vertical and horizontal structures of rain have been considered. The elevation angle we have chosen is ~ 560 as most of the stations in India havethat value of elevation angle with geostationary satellite. Taking the frequencies 11 to 14 GHz separately and 00 C isotherm height as 5.0 km, the effective rain height values are determined. The attenuation of radio waves due to rain are calculated for different rain rates assigning different γ-values. The attenuation is found to vary significantly with the γ-values. Also the attenuation curves are closer when the γ-values are of low order. An increase in attenuation with the γ-values is found to be more prominent for higher rain rates.

  17. Determination of total mass attenuation coefficients, effective atomic numbers and electron densities for different shielding materials

    International Nuclear Information System (INIS)

    Highlights: • The gamma shielding properties of eight shielding materials have been investigated. • We calculated the total mass attenuation coefficients by using WinXCom program. • The values of effective atomic number and electron density are also calculated. • All parameters depend on chemical content and the incident photon energy. • The Field castable Heat Resistant is the most effective shielding material. - Abstract: In this paper, the interaction of gamma rays with some shielding materials has been studied. The total mass attenuation coefficient (μt) for eight shielding materials has been calculated by using WinXCOM program in the energy range from 1 keV to 100 GeV. Also, the effective atomic number (Zeff) and the effective electron density (Neff) were calculated using the values of the total mass attenuation coefficient. The dependence of these parameters on the incident photon energy and the chemical composition has been examined

  18. Frustrated total internal reflection and the illusion of superluminal propagation

    CERN Document Server

    Brudny, Vera L

    2008-01-01

    We analyze the propagation of a pulse across a vacuum gap separating opposite flat parallel faces of two transparent dielectrics by means of an explicitly causal and retarded propagator constructed directly from the free-space wave equation. Nevertheless, our approach yields apparently superluminal propagation for the case of frustrated total internal reflection (FTIR), that is, a transmitted wave packet appears on the far side of the gap at the same time that the corresponding incident packet crosses the front one. Thus, in this example superluminality is just an illusion, being consistent with both casuality and classical electrodynamics. We study the origin of the apparent superluminality in this case, which is inherent to light pulse propagation in free space and does not depend on the particulars of light-matter interaction, and find that it is due to propagation from the lateral wings of the incident pulse to the central part of the transmitted pulse. Thus, notwithstanding their similarities, FTIR is no...

  19. Single-Molecule Total Internal Reflection Fluorescence Microscopy.

    Science.gov (United States)

    Kudalkar, Emily M; Davis, Trisha N; Asbury, Charles L

    2016-01-01

    The advent of total internal reflection fluorescence (TIRF) microscopy has permitted visualization of biological events on an unprecedented scale: the single-molecule level. Using TIRF, it is now possible to view complex biological interactions such as cargo transport by a single molecular motor or DNA replication in real time. TIRF allows for visualization of single molecules by eliminating out-of-focus fluorescence and enhancing the signal-to-noise ratio. TIRF has been instrumental for studying in vitro interactions and has also been successfully implemented in live-cell imaging. Visualization of cytoskeletal structures and dynamics at the plasma membrane, such as endocytosis, exocytosis, and adhesion, has become much clearer using TIRF microscopy. Thanks to recent advances in optics and commercial availability, TIRF microscopy is becoming an increasingly popular and user-friendly technique. In this introduction, we describe the fundamental properties of TIRF microscopy and the advantages of using TIRF for single-molecule investigation. PMID:27140922

  20. Coverslip Cleaning and Functionalization for Total Internal Reflection Fluorescence Microscopy.

    Science.gov (United States)

    Kudalkar, Emily M; Deng, Yi; Davis, Trisha N; Asbury, Charles L

    2016-01-01

    Total internal reflection fluorescence (TIRF) microscopy allows visualization of biological events at the single-molecule level by restricting excitation to a precise focal plane near the coverslip and eliminating out-of-focus fluorescence. The quality of TIRF imaging relies on a high signal-to-noise ratio and therefore it is imperative to prevent adherence of molecules to the glass coverslip. Nonspecific interactions can make it difficult to distinguish true binding events and may also interfere with accurate quantification of background noise. In addition, nonspecific binding of the fluorescently tagged protein will lower the effective working concentration, thereby altering values used to calculate affinity constants. To prevent spurious interactions, we thoroughly clean the surface of the coverslip and then functionalize the glass either by applying a layer of silane or by coating with a lipid bilayer. PMID:27140911

  1. Absolute Position Total Internal Reflection Microscopy with an Optical Tweezer

    CERN Document Server

    Liu, Lulu; Rodriguez, Alejandro W; Capasso, Federico

    2014-01-01

    A non-invasive, in-situ calibration method for Total Internal Reflection Microscopy (TIRM) based on optical tweezing is presented which greatly expands the capabilities of this technique. We show that by making only simple modifications to the basic TIRM sensing setup and procedure, a probe particle's absolute position relative to a dielectric interface may be known with better than 10 nm precision out to a distance greater than 1 $\\mu$m from the surface. This represents an approximate 10x improvement in error and 3x improvement in measurement range over conventional TIRM methods. The technique's advantage is in the direct measurement of the probe particle's scattering intensity vs. height profile in-situ, rather than relying on calculations or inexact system analogs for calibration. To demonstrate the improved versatility of the TIRM method in terms of tunability, precision, and range, we show our results for the hindered near-wall diffusion coefficient for a spherical dielectric particle.

  2. Removal cross sections and total mass attenuation coefficients of fast neutrons and gamma rays for steel

    CERN Document Server

    Elsayed, A A

    2003-01-01

    The present work deals with the study of the attenuation properties and determination of the cross sections of fast neutrons and gamma rays for structure steel used in different applications in nuclear power plants, particle accelerators, research reactors and different radiation attenuation fields. Investigation has been performed by measuring the transmitted fast neutron and gamma ray spectra behind cylindrical samples of steel (rho=7.87 gem sup - sup 3) of different thicknesses. A reactor collimated beam and neutron - gamma spectrometer with stiblbene scintillator were used for measurements. The pluse shape disriminate technique based on zero cross over method was used to discriminate between neutron and gamma ray pulses. Effective removal cross-section (sigma sub R) and total mass attenuation coefficient (mu) of neureons and gamma rays have been achieved using the attenuation relations. Microscopic removal cross sections sigma sup 9 sup 8 and mass removal cross sections sigma sub R sub / subrho of fast ne...

  3. Attenuation of front-end reflections in an impulse radar using high-speed switching

    Science.gov (United States)

    Mazzaro, Gregory J.; Ressler, Marc A.; Smith, Gregory D.

    2011-06-01

    Pulse reflection between front-end components is a common problem for impulse radar systems. Such reflections arise because radio frequency components are rarely impedance-matched over an ultra-wide bandwidth. Any mismatch between components causes a portion of the impulse to reflect within the radar front-end. If the reflection couples into the transmit antenna, the radar emits an unintended, delayed and distorted replica of the intended radar transmission. These undesired transmissions reflect from the radar environment, produce echoes in the radar image, and generate false alarms in the vicinity of actual targets. The proposed solution for eliminating these echoes, without redesigning the transmit antenna, is to dissipate pulse reflections in a matched load before they are emitted. A high-speed switch directs the desired pulse to the antenna and redirects the undesired reflection from the antenna to a matched load. The Synchronous Impulse Reconstruction (SIRE) radar developed by the Army Research Laboratory (ARL) is the case-study. This paper reviews the current front-end design, provides a recent radar image which displays the aforementioned echoes, and describes the switch-cable-load circuit solution for eliminating the echoes. The consequences of inserting each portion of the new hardware into the radar front-end are explained. Measurements on the front-end with the high-speed switch show an attenuation of the undesired pulse transmissions of more than 18 dB and an attenuation in the desired pulse transmission of less than 3 dB.

  4. Removal cross sections and total mass attenuation coefficients of fast neutrons and gamma rays for steel

    International Nuclear Information System (INIS)

    The present work deals with the study of the attenuation properties and determination of the cross sections of fast neutrons and gamma rays for structure steel used in different applications in nuclear power plants, particle accelerators, research reactors and different radiation attenuation fields. Investigation has been performed by measuring the transmitted fast neutron and gamma ray spectra behind cylindrical samples of steel (ρ=7.87 gem-3) of different thicknesses. A reactor collimated beam and neutron - gamma spectrometer with stiblbene scintillator were used for measurements. The pluse shape disriminate technique based on zero cross over method was used to discriminate between neutron and gamma ray pulses. Effective removal cross-section (σR) and total mass attenuation coefficient (μ) of neureons and gamma rays have been achieved using the attenuation relations. Microscopic removal cross sections σ98 and mass removal cross sections σR/ρ of fast neutrons have been evaluated based on measured results and definite energies. Also, total mass attenuation coefficients (μ/σ) of gamma rays have been evalusted and calculated using measured results and XCOM code respectively. Comparison between measured and calculated results shows a resonable agreement between the two

  5. Measurement uncertainty in Total Reflection X-ray Fluorescence

    International Nuclear Information System (INIS)

    Total Reflection X-ray Fluorescence (TXRF) spectrometry is a multi-elemental technique using micro-volumes of sample. This work assessed the components contributing to the combined uncertainty budget associated with TXRF measurements using Cu and Fe concentrations in different spiked and natural water samples as an example. The results showed that an uncertainty estimation based solely on the count statistics of the analyte is not a realistic estimation of the overall uncertainty, since the depositional repeatability and the relative sensitivity between the analyte and the internal standard are important contributions to the uncertainty budget. The uncertainty on the instrumental repeatability and sensitivity factor could be estimated and as such, potentially relatively straightforward implemented in the TXRF instrument software. However, the depositional repeatability varied significantly from sample to sample and between elemental ratios and the controlling factors are not well understood. By a lack of theoretical prediction of the depositional repeatability, the uncertainty budget can be based on repeat measurements using different reflectors. A simple approach to estimate the uncertainty was presented. The measurement procedure implemented and the uncertainty estimation processes developed were validated from the agreement with results obtained by inductively coupled plasma — optical emission spectrometry (ICP-OES) and/or reference/calculated values. - Highlights: • The uncertainty of TXRF cannot be realistically described by the counting statistics. • The depositional repeatability is an important contribution to the uncertainty. • Total combined uncertainties for Fe and Cu in waste/mine water samples were 4–8%. • Obtained concentrations agree within uncertainty with reference values

  6. Measurement uncertainty in Total Reflection X-ray Fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Floor, G.H., E-mail: geerke.floor@gfz-potsdam.de [GFZ German Research Centre for Geosciences Section 3.4. Earth Surface Geochemistry, Telegrafenberg, 14473 Postdam (Germany); Queralt, I. [Institute of Earth Sciences Jaume Almera ICTJA-CSIC, Solé Sabaris s/n, 08028 Barcelona (Spain); Hidalgo, M.; Marguí, E. [Department of Chemistry, University of Girona, Campus Montilivi s/n, 17071 Girona (Spain)

    2015-09-01

    Total Reflection X-ray Fluorescence (TXRF) spectrometry is a multi-elemental technique using micro-volumes of sample. This work assessed the components contributing to the combined uncertainty budget associated with TXRF measurements using Cu and Fe concentrations in different spiked and natural water samples as an example. The results showed that an uncertainty estimation based solely on the count statistics of the analyte is not a realistic estimation of the overall uncertainty, since the depositional repeatability and the relative sensitivity between the analyte and the internal standard are important contributions to the uncertainty budget. The uncertainty on the instrumental repeatability and sensitivity factor could be estimated and as such, potentially relatively straightforward implemented in the TXRF instrument software. However, the depositional repeatability varied significantly from sample to sample and between elemental ratios and the controlling factors are not well understood. By a lack of theoretical prediction of the depositional repeatability, the uncertainty budget can be based on repeat measurements using different reflectors. A simple approach to estimate the uncertainty was presented. The measurement procedure implemented and the uncertainty estimation processes developed were validated from the agreement with results obtained by inductively coupled plasma — optical emission spectrometry (ICP-OES) and/or reference/calculated values. - Highlights: • The uncertainty of TXRF cannot be realistically described by the counting statistics. • The depositional repeatability is an important contribution to the uncertainty. • Total combined uncertainties for Fe and Cu in waste/mine water samples were 4–8%. • Obtained concentrations agree within uncertainty with reference values.

  7. Determination of technetium by total reflection x-ray fluorescence

    International Nuclear Information System (INIS)

    We describe a technique using total reflection x-ray fluorescence (TXRF) for determination of Technetium produced by elution of chromatography generators with physiological saline solutions. The analysis with the 18.41 keV Kα line of Technetium was accomplished with monochromatized Kα radiation from a silver anode x-ray tube operated at 45 keV and 20 mA. This radiation at 22.104 keV is efficiently coupled to the 21.054 keV absorption edge of Tc. It is also of advantage in the direct analysis of organic and saline properties of the Tc-bearing samples. Quantification was accomplished by internal standard addition of Ga and using an interpolated value of the sensitivity for Tc between Molybdenum and Rhenium. Data processing was carried out with the QXAS-AXIL software package. System sensitivity was found adequate for direct Tc determination of eluted saline solutions. The interest and advantages of the use of the technique as an auxiliary in the synthesis and characterization of Tc-labeled radiopharmaceuticals used for diagnosis in nuclear medicine are discussed. Detection limits in the matrices analyzed are reported. (author)

  8. Data Analysis for Total Internal Reflection Fluorescence Microscopy.

    Science.gov (United States)

    Asbury, Charles L

    2016-01-01

    In the microscopes we use to analyze total internal reflection fluorescence (TIRF), the emitted fluorescence is split chromatically, using dichroic filters, into either two or three different colors ("channels"). In our two-color instrument, the green emission wavelengths (405-488 nm; for imaging green fluorescent protein [GFP]-tagged proteins) and far-red emission wavelengths (650-800 nm; for imaging Alexa-647-labeled microtubules) are projected onto the upper and lower halves, respectively, of a single camera. A single filter can be swapped to collect near-red wavelengths (561-640 nm; for imaging mCherry, or Alexa-568-labeled microtubules) instead of far-red. Our three-color instrument is very similar except that the green, near-red, and far-red color ranges are projected onto three separate cameras. In either case, the different colors can be imaged simultaneously. Typically, we collect images at 10 frames/sec for ∼200 sec. We have developed a series of semiautomated image analysis programs, written in LabView, to obtain the brightness, residence time, and mobility of individual particles bound to single microtubules. The basic analysis steps are straightforward and could also be implemented using ImageJ or Matlab. For convenience, this protocol describes the analysis of a single microtubule. Data from many microtubules across many experimental trials are needed to obtain robust conclusions that are independent of stochastic and trial-to-trial variability. PMID:27140913

  9. The measurement of total mass attenuation coefficients of CoCuNi alloys

    International Nuclear Information System (INIS)

    The total mass attenuation coefficients for Co, Cu, Ni elements and CoCu, CoCuNi alloys were measured at different energies with 11.88, 13.93, 17.59, 21.09 and 26.00 keV emitted an 241Am point source using transmission arrangement. The gamma rays were counted by a Si(Li) detector with a resolution of 160 eV at 5.9 keV. Also the mass attenuation coefficients of each alloy (CoCu, CoCuNi) were estimated using mixture rule. The measured values were compared with estimated values for alloys

  10. Transmission, attenuation and reflection of shear waves in the human brain

    OpenAIRE

    Clayton, Erik H.; Guy M. Genin; Bayly, Philip V.

    2012-01-01

    Traumatic brain injuries (TBIs) are caused by acceleration of the skull or exposure to explosive blast, but the processes by which mechanical loads lead to neurological injury remain poorly understood. We adapted motion-sensitive magnetic resonance imaging methods to measure the motion of the human brain in vivo as the skull was exposed to harmonic pressure excitation (45, 60 and 80 Hz). We analysed displacement fields to quantify the transmission, attenuation and reflection of distortional (...

  11. Attenuator design for organs at risk in total body irradiation using a translation technique

    International Nuclear Information System (INIS)

    Total body irradiation (TBI) is an efficient part of the treatment for malignant hematological diseases. Dynamic TBI techniques provide great advantages (e.g., dose homogeneity, patient comfort) while overcoming treatment room space restrictions. However, with dynamic techniques come additional organs at risk (OAR) protection challenges. In most dynamic TBI techniques, lead attenuators are used to diminish the dose received by the OARs. The purpose of this study was to characterize the dose deposition under various shapes of attenuators in static and dynamic treatments. This characterization allows for the development of a correction method to improve attenuator design in dynamic treatments. The dose deposition under attenuators at different depths in dynamic treatment was compared with the static situation based on two definitions: the coverage areas and the penumbra regions. The coverage area decreases with depth in dynamic treatment while it is stable for the static situation. The penumbra increases with depth in both treatment modes, but the increasing rate is higher in the dynamic situation. Since the attenuator coverage is deficient in the dynamic treatment mode, a correction method was developed to modify the attenuator design in order to improve the OAR protection. The correction method is divided in two steps. The first step is based on the use of elongation charts, which provide appropriate attenuator coverage and acceptable penumbra for a specific depth. The second point is a correction method for the thoracic inclination, which can introduce an orientation problem in both static and dynamic treatments. This two steps correction method is simple to use and personalized to each patient's anatomy. It can easily be adapted to any dynamic TBI techniques

  12. Quo Vadis total reflection X-ray fluorescence?

    International Nuclear Information System (INIS)

    The multielement trace analytical method 'total reflection X-ray fluorescence' (TXRF) has become a successfully established method in the semiconductor industry, particularly, in the ultra trace element analysis of silicon wafer surfaces. TXRF applications can fulfill general industrial requirements on daily routine of monitoring wafer cleanliness up to 300 mm diameter under cleanroom conditions. Nowadays, TXRF and hyphenated TXRF methods such as 'vapor phase decomposition (VPD)-TXRF', i.e. TXRF with a preceding surface and acid digestion and preconcentration procedure, are automated routine techniques ('wafer surface preparation system', WSPS). A linear range from 108 to 1014 [atoms/cm2] for some elements is regularly controlled. Instrument uptime is higher than 90%. The method is not tedious and can automatically be operated for 24 h/7 days. Elements such as S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Br, Sn, Sb, Ba and Pb are included in the software for standard peak search. The detection limits of recovered elements are between 1x1011 and 1x107 [atoms/cm2] depending upon X-ray excitation energy and the element of interest. For the determination of low Z elements, i.e. Na, Al and Mg, TXRF has also been extended but its implementation for routine analysis needs further research. At present, VPD-TXRF determination of light elements is viable in a range of 109 [atoms/cm2]. Novel detectors such as silicon drift detectors (SDD) with an active area of 5 mm2, 10 mm2 or 20 mm2, respectively, and multi-array detectors forming up to 70 mm2 are commercially available. The first SDD with 100 mm2 (!) area and integrated backside FET is working under laboratory conditions. Applications of and comparison with ICP-MS, HR-ICP-MS and SR-TXRF, an extension of TXRF capabilities with an extremely powerful energy source, are also reported

  13. Total internal reflection and dynamic light scattering microscopy of gels

    Science.gov (United States)

    Gregor, Brian F.

    Two different techniques which apply optical microscopy in novel ways to the study of biological systems and materials were built and applied to several samples. The first is a system for adapting the well-known technique of dynamic light scattering (DLS) to an optical microscope. This can detect and scatter light from very small volumes, as compared to standard DLS which studies light scattering from volumes 1000x larger. The small scattering volume also allows for the observation of nonergodic dynamics in appropriate samples. Porcine gastric mucin (PGM) forms a gel at low pH which lines the epithelial cell layer and acts as a protective barrier against the acidic stomach environment. The dynamics and microscopic viscosity of PGM at different pH levels is studied using polystyrene microspheres as tracer particles. The microscopic viscosity and microrheological properties of the commercial basement membrane Matrigel are also studied with this instrument. Matrigel is frequently used to culture cells and its properties remain poorly determined. Well-characterized and purely synthetic Matrigel substitutes will need to have the correct rheological and morphological characteristics. The second instrument designed and built is a microscope which uses an interferometry technique to achieve an improvement in resolution 2.5x better in one dimension than the Abbe diffraction limit. The technique is based upon the interference of the evanescent field generated on the surface of a prism by a laser in a total internal reflection geometry. The enhanced resolution is demonstrated with fluorescent samples. Additionally. Raman imaging microscopy is demonstrated using the evanescent field in resonant and non-resonant samples, although attempts at applying the enhanced resolution technique to the Raman images were ultimately unsuccessful. Applications of this instrument include high resolution imaging of cell membranes and macroscopic structures in gels and proteins. Finally, a third

  14. Total mass attenuation coefficient evaluation of ten materials commonly used to simulate human tissue

    International Nuclear Information System (INIS)

    To study the doses received by patient submitted to ionizing radiation, several materials are used to simulate the human tissue and organs. The total mass attenuation coefficient is a reasonable way for evaluating the usage in dosimetry of these materials. The total mass attenuation coefficient is determined by photon energy and constituent elements of the material. Currently, the human phantoms are composed by a unique material that presents characteristics similar to the mean proprieties of the different tissues within the region. Therefore, the phantoms are usually homogeneous and filled with a material similar to soft tissue. We studied ten materials used as soft tissue-simulating. These materials were named: bolus, nylon, orange articulation wax, red articulation wax, PMMA, modelling clay, bee wax, paraffin 1, paraffin 2 and pitch. The objective of this study was to verify the best material to simulate the human cerebral tissue. We determined the elementary composition, mass density and, therefore, calculated the total mass attenuation coefficient of each material. The results were compared to the values established by the International Commission on Radiation Units and Measurements - ICRU, report n0 44, and by the International Commission on Radiation Protection - ICRP, report n0 89, to determine the best material for this energy interval. These results indicate that new head phantoms can be constructed with nylon.

  15. Total mass attenuation coefficient evaluation of ten materials commonly used to simulate human tissue

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, C C; Ximenes, R E; Garcia, C A B; Vieira, J W; Maia, A F, E-mail: ccosta@fisica.ufs.b

    2010-11-01

    To study the doses received by patient submitted to ionizing radiation, several materials are used to simulate the human tissue and organs. The total mass attenuation coefficient is a reasonable way for evaluating the usage in dosimetry of these materials. The total mass attenuation coefficient is determined by photon energy and constituent elements of the material. Currently, the human phantoms are composed by a unique material that presents characteristics similar to the mean proprieties of the different tissues within the region. Therefore, the phantoms are usually homogeneous and filled with a material similar to soft tissue. We studied ten materials used as soft tissue-simulating. These materials were named: bolus, nylon, orange articulation wax, red articulation wax, PMMA, modelling clay, bee wax, paraffin 1, paraffin 2 and pitch. The objective of this study was to verify the best material to simulate the human cerebral tissue. We determined the elementary composition, mass density and, therefore, calculated the total mass attenuation coefficient of each material. The results were compared to the values established by the International Commission on Radiation Units and Measurements - ICRU, report n0 44, and by the International Commission on Radiation Protection - ICRP, report n0 89, to determine the best material for this energy interval. These results indicate that new head phantoms can be constructed with nylon.

  16. Depth and Reflection Total Variation for Single Image Dehazing

    OpenAIRE

    Wang, Wei; He, Chuanjiang

    2016-01-01

    Haze removal has been a very challenging problem due to its ill-posedness, which is more ill-posed if the input data is only a single hazy image. In this paper, we present a new approach for removing haze from a single input image. The proposed method combines the model widely used to describe the formation of a haze image with the assumption in Retinex that an image is the product of the illumination and the reflection. We assume that the depth and reflection functions are spatially piecewis...

  17. Received Power Attenuation Analysis Based on Wavelet for Reflection-Style Optical Antenna Deformations in Free-Space Laser Communications

    OpenAIRE

    Wanqing Xie; Liying Tan; Jing Ma; Yang Liu

    2011-01-01

    Diversified deformations on reflection-style optical antennas caused by processing technique and complex outer-space environment in free-space laser communications are modeled by wavelet analysis. Influence due to the deformations on received power is studied by distortion attenuation factor based on the model. Theoretical and numerical analysis shows that distortion attenuation factor increases with shift factor of the model, decreases with dilation factor of the model, and decreases with ir...

  18. A visual classroom demonstration of frustrated total internal reflection as an analogue to optical tunnelling

    Science.gov (United States)

    Salman, Rabiya; Rashid, Shama; Sabieh Anwar, Muhammad

    2013-11-01

    Frustrated total internal reflection is presented as a visually attractive and convenient classroom demonstration. Optical evanescent waves penetrating through a dielectric barrier is a classical analogue to quantum mechanical tunnelling. We use the traditional double prism arrangement to demonstrate the pickup and relaunching of the evanescent wave. Total internal reflection could be completely frustrated by the insertion of an index matching fluid.

  19. Effective atomic numbers and mass attenuation coefficients of some thermoluminescent dosimetric compounds for total photon interaction

    International Nuclear Information System (INIS)

    Effective atomic numbers for total gamma-ray interaction with some selected thermoluminescent dosimetric compounds such as barium acetate, barium sulfate, calcium carbonate, calcium sulfate, calcium sulfate dihydrate, cadmium sulfate (anhydrous), cadmium sulfate, strontium sulfate, and lithium fluoride have been calculated in the 1-keV to 20-MeV energy region. Experimental mass attenuation coefficients and effective atomic numbers for these compounds at selected photon energies of 26.3, 33.2, 59.54, and 661.6 keV have been obtained from good geometry transmission measurements and compared with theoretical values. The effect of absorption edge on effective atomic numbers and its variation with energy, and nonvalidity of the Bragg's mixture rule at incident photon energies closer to the absorption edges of constituent elements of compounds are discussed

  20. Total transmission and total reflection of acoustic wave by zero index metamaterials loaded with general solid defects

    OpenAIRE

    Wang, Ziyu; Yang, Fan; Liu, Libing; Kang, Ming; Liu, Fengming

    2013-01-01

    This work investigates acoustic wave transmission property through a zero index metamaterials (ZIM) waveguide embedded with a general solid defect. Total transmission and total reflection can be achieved by adjusting the parameters of the solid defect. We comprehensively study how longitudinal/transverse wave speeds of the solid defect affect the acoustic wave propagation through the waveguide. A two-dimensional (2D) acoustic crystals (ACs) system with zero index is used to realize these intr...

  1. Visco-thermal effects in acoustic metamaterials: from total transmission to total reflection and high absorption

    Science.gov (United States)

    Molerón, Miguel; Serra-Garcia, Marc; Daraio, Chiara

    2016-03-01

    We theoretically and experimentally investigate visco-thermal effects on the acoustic propagation through metamaterials consisting of rigid slabs with subwavelength slits embedded in air. We demonstrate that this unavoidable loss mechanism is not merely a refinement, but that it plays a dominant role in the actual acoustic response of the structure. Specifically, in the case of very narrow slits, the visco-thermal losses avoid completely the excitation of Fabry-Perot resonances, leading to 100% reflection. This is exactly opposite to the perfect transmission predicted in the idealised lossless case. Moreover, for a wide range of geometrical parameters, there exists an optimum slit width at which the energy dissipated in the structure can be as high as 50%. This work provides a clear evidence that visco-thermal effects are necessary to describe realistically the acoustic response of locally resonant metamaterials.

  2. Visco-thermal effects in acoustic metamaterials: from total transmission to total reflection and high absorption

    CERN Document Server

    Molerón, Miguel; Daraio, Chiara

    2015-01-01

    We theoretically and experimentally investigate visco-thermal effects on the acoustic propagation through metamaterials consisting of rigid slabs with subwavelength slits embedded in air. We demonstrate that this unavoidable loss mechanism is not merely a refinement, but it plays a dominant role in the actual acoustic response of the structure. Specifically, in the case of very narrow slits, the visco-thermal losses avoid completely the excitation of Fabry-Perot resonances, leading to 100% reflection. This is exactly opposite to the perfect transmission predicted in the idealised lossless case. Moreover, for a wide range of geometrical parameters, there exists an optimum slit width at which the energy dissipated in the structure can be as high as 50%. This work provides a clear evidence that visco-thermal effects are necessary to describe realistically the acoustic response of locally resonant metamaterials.

  3. An ice-sheet wide framework for englacial attenuation and basal reflection from ice penetrating radar data

    Science.gov (United States)

    Jordan, Thomas; Bamber, Jonathan; Williams, Chris; Paden, John; Siegert, Martin; Huybrechts, Philippe; Gagliardini, Olivier; Gillet-Chaulet, Fabien

    2016-04-01

    Radar-inference of the bulk material properties of glacier beds, most notably identifying basal melting, is, in general, derived from the basal reflection coefficient. Unambiguous determination of basal reflection is primarily limited by uncertainty in the spatial variation of the englacial attenuation of the radio wave. Arrhenius temperature models predict that, over the extent of an ice-sheet, the depth-averaged attenuation rate can vary by a factor of ~ 6-8. However, existing `bed-returned power' radar algorithms for basal reflection assume stationarity in the depth-averaged attenuation rate. These radar algorithms are therefore only applicable to local regions of ice-sheets, and are suspected to yield erroneous values for basal reflection. Here we introduce an automated, Greenland wide, framework for radar-inference of englacial attenuation and basal reflection. To demonstrate its efficacy we apply it to recent, (2011-2014), Operation Ice Bridge data. A central feature is the use of a prior Arrhenius temperature model to estimate the spatial variation in radar attenuation as a first guess input for the radar algorithm. Specifically, this estimate is used to test for sample regions where the assumption of stationarity is valid within some specified tolerance, and to modify the bed-returned power method for local attenuation variation within each sample region. The radar algorithm is validated in a number of different ways. Firstly, we demonstrate regions of solution convergence for two different input temperature fields; the steady-state temperature fields for the SICOPOLIS and GISM ice-sheet models. Secondly, we show that, for regions of data coverage overlap, the algorithm is repeatable for different field campaign years. Thirdly, we illustrate that, for the coverage achieved, the predicted range for the basal reflection coefficient is ~ 20 dB, which is consistent with the predicted range for the basal material interface (~15 dB) and our uncertainty estimate

  4. Optical computation based on nonlinear total reflectional optical switch at the interface

    Indian Academy of Sciences (India)

    Jianqi Zhang; Huan Xu

    2009-03-01

    A new scheme of binary half adder and full adder is proposed. It realizes a kind of all-optical computation which is based on the polarization coding technique and the nonlinear total reflectional optical switches.

  5. Forensic application of total reflection X-ray fluorescence spectrometry for elemental characterization of ink samples

    Energy Technology Data Exchange (ETDEWEB)

    Dhara, Sangita [Fuel Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Misra, N.L., E-mail: nlmisra@barc.gov.i [Fuel Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Maind, S.D. [NAA Unit of Central Forensic Science Laboratory Hyderabad at Analytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Kumar, Sanjukta A. [Analytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Chattopadhyay, N. [NAA Unit of Central Forensic Science Laboratory Hyderabad at Analytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Aggarwal, S.K. [Fuel Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India)

    2010-02-15

    The possibility of applying Total Reflection X-ray Fluorescence for qualitative and quantitative differentiation of documents printed with rare earth tagged and untagged inks has been explored in this paper. For qualitative differentiation, a very small amount of ink was loosened from the printed documents by smoothly rubbing with a new clean blade without destroying the manuscript. 50 muL of Milli-Q water was put on this loose powder, on the manuscript, and was agitated by sucking and releasing the suspension two to three times with the help of a micropipette. The resultant dispersion was deposited on quartz sample support for Total Reflection X-ray Fluorescence measurements. The Total Reflection X-ray Fluorescence spectrum of tagged and untagged inks could be clearly differentiated. In order to see the applicability of Total Reflection X-ray Fluorescence for quantitative determinations of rare earths and also to countercheck such determinations in ink samples, the amounts of rare earth in painted papers with single rare earth tagged inks were determined by digesting the painted paper in HNO{sub 3}/HClO{sub 4}, mixing this solution with the internal standard and recording their Total Reflection X-ray Fluorescence spectra after calibration of the instrument. The results thus obtained were compared with those obtained by Inductively Coupled Plasma Mass Spectrometry and were found in good agreement. The average precision of the Total Reflection X-ray Fluorescence determinations was 5.5% (1sigma) and the average deviation of Total Reflection X-ray Fluorescence determined values with that of Inductively Coupled Plasma Mass Spectrometry was 7.3%. These studies have shown that Total Reflection X-ray Fluorescence offers a promising and potential application in forensic work of this nature.

  6. Forensic application of total reflection X-ray fluorescence spectrometry for elemental characterization of ink samples

    International Nuclear Information System (INIS)

    The possibility of applying Total Reflection X-ray Fluorescence for qualitative and quantitative differentiation of documents printed with rare earth tagged and untagged inks has been explored in this paper. For qualitative differentiation, a very small amount of ink was loosened from the printed documents by smoothly rubbing with a new clean blade without destroying the manuscript. 50 μL of Milli-Q water was put on this loose powder, on the manuscript, and was agitated by sucking and releasing the suspension two to three times with the help of a micropipette. The resultant dispersion was deposited on quartz sample support for Total Reflection X-ray Fluorescence measurements. The Total Reflection X-ray Fluorescence spectrum of tagged and untagged inks could be clearly differentiated. In order to see the applicability of Total Reflection X-ray Fluorescence for quantitative determinations of rare earths and also to countercheck such determinations in ink samples, the amounts of rare earth in painted papers with single rare earth tagged inks were determined by digesting the painted paper in HNO3/HClO4, mixing this solution with the internal standard and recording their Total Reflection X-ray Fluorescence spectra after calibration of the instrument. The results thus obtained were compared with those obtained by Inductively Coupled Plasma Mass Spectrometry and were found in good agreement. The average precision of the Total Reflection X-ray Fluorescence determinations was 5.5% (1σ) and the average deviation of Total Reflection X-ray Fluorescence determined values with that of Inductively Coupled Plasma Mass Spectrometry was 7.3%. These studies have shown that Total Reflection X-ray Fluorescence offers a promising and potential application in forensic work of this nature.

  7. Amplitude Variation of Bottom Simulating Reflection with Respect to Frequency - Transitional Base or Attenuation?

    Science.gov (United States)

    Lee, Myung W.

    2007-01-01

    The amplitude of a bottom simulating reflection (BSR), which occurs near the phase boundary between gas hydrate-bearing sediments and underlying gas-filled sediments, strongly depends on the frequency content of a seismic signal, as well as the impedance contrast across the phase boundary. A strong-amplitude BSR, detectable in a conventional seismic profile, is a good indicator of the presence of free gas beneath the phase boundary. However, the BSR as observed in low-frequency multichannel seismic data is generally difficult to identify in high-frequency, single-channel seismic data. To investigate the frequency dependence of BSR amplitudes, single-channel seismic data acquired with an air gun source at Blake Ridge, which is located off the shore of South Carolina, were analyzed in the frequency range of 10-240 Hz. The frequency-dependent impedance contrast caused by the velocity dispersion in partially gas saturated sediments is important to accurately analyze BSR amplitude. Analysis indicates that seismic attenuation of gas hydrate-bearing sediments, velocity dispersion, and a transitional base all contribute to the frequency-dependent BSR amplitude variation in the frequency range of 10-500 Hz. When velocity dispersion is incorporated into the BSR amplitude analysis, the frequency-dependent BSR amplitude at Blake Ridge can be explained with gas hydrate-bearing sediments having a quality factor of about 250 and a transitional base with a thickness of about 1 meter.

  8. Frustrated Total Internal Reflection: Resonant and Negative Goos-H\\"anchen Shifts in Microwave Regime

    CERN Document Server

    Qu, Min

    2010-01-01

    It is well-known that the variations of Goos-H\\"anchen shifts (GHSs) are closely associated with the enengy-flux provided by evanescent states in the case of total internal reflection. However, when the frustrated internal total reflection (FTIR) is realized with a Polymethyl Methacrylate (PMMA) double-prism system operated in the microwave frequency range of 8.2 GHz to 12.4 GHz, we observe that the GH shifts for the reflected beam show periodic resonances with varying the operation frequency or the air layer thickness, which is different from the variation of the corresponding reflected energy. Moreover, in another FTIR based system introduced by a composite absorptive material slab with a two-dimensional top layer of frequency selective surface (FSS), the GHSs for reflected beam are discovered as not only resonant but also negative with the incidence of transverse electric that is TE polarized.

  9. Quantitative Total and Diffuse Reflectance Laboratory Measurements for Remote, Standoff, and Point Sensing

    Energy Technology Data Exchange (ETDEWEB)

    Blake, Thomas A.; Johnson, Timothy J.; Tonkyn, Russell G.; Forland, Brenda M.; Myers, Tanya L.; Brauer, Carolyn S.; Su, Yin-Fong

    2014-06-10

    Methods for making total and diffuse directional/hemispherical reflectance measurements in the shortwave to longwave infrared using an integrating sphere are described. The sphere is a commercial, off-the-shelf optical device with its sample port at the bottom, which is essential for examining powdered samples without using a cover glass. The reflectance spectra of recently-developed National Institute of Standards and Technology (NIST, USA) infrared reflectance standards have been measured using the sphere. Reflectance spectra of other materials such as Spectralon and Infragold were also measured. The relative systematic error for the total reflectance measurements is estimated to be on the order of 3%, and random measurement error for multiple samples of each material is on the order of 0.5%.

  10. Reflective variable optical attenuators and fibre ring lasers for wavelength-division multiplexing systems

    Science.gov (United States)

    Liu, He Liang

    Wavelength division multiplexing (WDM) optical fibre system is an important enabling technology to fulfill the demands for bandwidth in the modern information age. The main objective of this project is to study novel devices with the potential to enhance the performance of WDM systems. In particular, a novel reflective variable optical attenuator (RVOA) used for dynamic gain equalization (DGE) and fibre lasers based on an entirely new type of erbium-doped fibres with ultrawide tuning range were investigated theoretically and experimentally. We proposed a new type of RVOA device which could be potentially integrated with arrayed waveguide grating (AWG) to reduce the cost of DGE substantially. Initially, fibre-based RVOAs, fabricated with optical fibre components such as fibre coupler and Faraday rotator mirror, were investigated theoretically and experimentally. Larger attenuation range up to 22 dB was realized for fibre coupler-based ROVA with a Faraday rotator mirror and its polarization-dependent loss is about 0.5 dB. Then polymeric waveguide-based RVOAs were investigated theoretically and experimentally. Using an epoxy Novolak resin as core material and an UV-cured resin (Norland's NOA61) as cladding material, a polymeric waveguide RVOA was successfully fabricated. The dynamic 15 dB attenuation range was achieved and the PDL was less than 0.2 dB. The measured insertion loss of the polymeric waveguide RVOA was too large (about 18 dB) and was mainly induced by coupling loss, material loss and poor alignment. In the second part of the study, fibre ring lasers with continuous wavelength tuning over wide wavelength range and fibre ring lasers with discrete wavelength tuning were investigated. Tunable lasers are important devices in WDM systems because they could be employed as reserved sources and therefore avoiding the need to stock large inventory of lasers to cover the ITU-wavelength grid. In this project, erbium ions doped bismuth oxide glass fibres instead of

  11. Dynamical measurement of refractive index distribution using digital holographic interferometry based on total internal reflection.

    Science.gov (United States)

    Zhang, Jiwei; Di, Jianglei; Li, Ying; Xi, Teli; Zhao, Jianlin

    2015-10-19

    We present a method for dynamically measuring the refractive index distribution in a large range based on the combination of digital holographic interferometry and total internal reflection. A series of holograms, carrying the index information of mixed liquids adhered on a total reflection prism surface, are recorded with CCD during the diffusion process. Phase shift differences of the reflected light are reconstructed exploiting the principle of double-exposure holographic interferometry. According to the relationship between the reflection phase shift difference and the liquid index, two dimensional index distributions can be directly figured out, assuming that the index of air near the prism surface is constant. The proposed method can also be applied to measure the index of solid media and monitor the index variation during some chemical reaction processes. PMID:26480394

  12. Computed-tomography attenuation values of the peritoneum reflect the severity of peritonitis due to upper gastrointestinal perforations

    International Nuclear Information System (INIS)

    The aim of this study was to evaluate computed tomography (CT) attenuation values of the peritoneum and to relate these values to the severity of peritonitis in patients with upper gastrointestinal tract (UGI) perforations. A total of 27 consecutive patients with UGI perforations who underwent CT and emergency laparotomy in our hospital were enrolled in this study. The CT attenuation values of the peritoneum were measured at a workstation by 2 independent investigators, and these values were analyzed in relation to the severity of illness. There were significant negative correlations between the peritoneal CT attenuation values and the sequential organ failure assessment score, acute physiology and chronic health evaluation II score, and the Mannheim peritonitis index. There was a significant negative correlation between the peritoneal CT attenuation values and the length of stay in the intensive care unit. Furthermore, patients with dysfunctions in ≥3 organs had significantly lower peritoneal CT attenuation values than those with dysfunction in ≤2 organs. In conclusion, evaluation of peritoneal CT attenuation values in peritonitis patients is simple and can be employed for objective assessment of the severity of peritonitis. (author)

  13. Total-reflection active-mirror laser with cryogenic Yb:YAG ceramics.

    Science.gov (United States)

    Furuse, Hiroaki; Kawanaka, Junji; Takeshita, Kenji; Miyanaga, Noriaki; Saiki, Taku; Imasaki, Kazuo; Fujita, Masayuki; Ishii, Shinya

    2009-11-01

    An efficient high-power laser operation has been demonstrated by using a cryogenic Yb:YAG composite ceramic with a total-reflection active-mirror arrangement. The composite ceramic, which had no high-reflection coating and was cooled with liquid nitrogen directly, showed four-level operation even at 67 kW/cm(3) of high pump density. A 273 W cw output power was obtained with 65% optical efficiency and 72% slope efficiency. PMID:19881620

  14. Monte Carlo simulation applied in total reflection x-ray fluorescence: Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Meira, Luiza L. C.; Inocente, Guilherme F.; Vieira, Leticia D.; Mesa, Joel [Departamento de Fisica e Biofisica - Instituto de Biociencias de Botucatu, Universidade Estadual Paulista Julio de Mesquita Filho (Brazil)

    2013-05-06

    The X-ray Fluorescence (XRF) analysis is a technique for the qualitative and quantitative determination of chemical constituents in a sample. This method is based on detection of the characteristic radiation intensities emitted by the elements of the sample, when properly excited. A variant of this technique is the Total Reflection X-ray Fluorescence (TXRF) that utilizes electromagnetic radiation as excitation source. In total reflection of X-ray, the angle of refraction of the incident beam tends to zero and the refracted beam is tangent to the sample support interface. Thus, there is a minimum angle of incidence at which no refracted beam exists and all incident radiation undergoes total reflection. In this study, we evaluated the influence of the energy variation of the beam of incident x-rays, using the MCNPX code (Monte Carlo NParticle) based on Monte Carlo method.

  15. Analysis of archaeological ceramics by total-reflection X-ray fluorescence: Quantitative approaches

    International Nuclear Information System (INIS)

    This paper reports the quantitative methodologies developed for the compositional characterization of archaeological ceramics by total-reflection X-ray fluorescence at two levels. A first quantitative level which comprises an acid leaching procedure, and a second selective level, which seeks to increase the number of detectable elements by eliminating the iron present in the acid leaching procedure. Total-reflection X-ray fluorescence spectrometry has been compared, at a quantitative level, with Instrumental Neutron Activation Analysis in order to test its applicability to the study of this kind of materials. The combination of a solid chemical homogenization procedure previously reported with the quantitative methodologies here presented allows the total-reflection X-ray fluorescence to analyze 29 elements with acceptable analytical recoveries and accuracies

  16. Analysis of archaeological ceramics by total-reflection X-ray fluorescence: Quantitative approaches

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Ruiz, R. [Servicio Interdepartamental de Investigacion, Facultad de Ciencias, Universidad Autonoma de Madrid, Modulo C-9, Laboratorio de TXRF, Crta. Colmenar, Km 15, Cantoblanco, E-28049, Madrid (Spain)], E-mail: ramon.fernandez@uam.es; Garcia-Heras, M. [Grupo de Arqueometria de Vidrios y Materiales Ceramicos, Instituto de Historia, Centro de Ciencias Humanas y Sociales, CSIC, C/ Albasanz, 26-28, 28037 Madrid (Spain)

    2008-09-15

    This paper reports the quantitative methodologies developed for the compositional characterization of archaeological ceramics by total-reflection X-ray fluorescence at two levels. A first quantitative level which comprises an acid leaching procedure, and a second selective level, which seeks to increase the number of detectable elements by eliminating the iron present in the acid leaching procedure. Total-reflection X-ray fluorescence spectrometry has been compared, at a quantitative level, with Instrumental Neutron Activation Analysis in order to test its applicability to the study of this kind of materials. The combination of a solid chemical homogenization procedure previously reported with the quantitative methodologies here presented allows the total-reflection X-ray fluorescence to analyze 29 elements with acceptable analytical recoveries and accuracies.

  17. Total-reflection X-ray fluorescence analysis of Austrian wine

    International Nuclear Information System (INIS)

    The concentration of major, minor and trace elements in Austrian wine was determined by total-reflection X-ray fluorescence using gallium as internal standard. A multi-elemental analysis was possible by pipetting 6 μl of wine directly on the reflector and drying. Total-reflection X-ray fluorescence analysis was performed with Atomika EXTRA II A (Cameca) X-rays from a Mo tube with a high-energy cut-off at 20 keV in total-reflection geometry. The results showed that it was possible to identify only by the elemental analysis as fingerprint the vineyards and year of vintage among 11 different wines

  18. Magneto-optical effects in multilayers illuminated by total internal reflection

    Science.gov (United States)

    Richard, N.; Dereux, A.; David, T.; Bourillot, E.; Goudonnet, J. P.; Scheurer, F.; Beaurepaire, E.; Garreau, G.

    1999-02-01

    This paper describes the magneto-optical effects of metallic multilayers under the condition of total internal reflection. In the framework of Green's dyadic technique, we detail a practical and at time-consuming scheme to compute accurately the optical properties of anisotropic multilayers deposited on a substrate. We present numerical simulations which account for the variation of the angle of incidence at a fixed wavelength and for the variation of the wavelength at fixed angle of incidence. The Kerr rotation is found to increase significantly around the critical angle for total reflection. We also discuss the importance of plasmon effects in the structure of the Kerr rotation spectra.

  19. Detection of Citrus Huanglongbing by Fourier Transform Infrared-Attenuated Total Reflection (FTIR-ATR) Spectroscopy

    Science.gov (United States)

    Citrus Huanglongbing (HLB, also known as citrus greening disease) was discovered in Florida in 2005 and is spreading rapidly amongst the citrus growing regions of the state. Detection via visual symptoms of the disease is not a long term viable option. New techniques are being developed to test fo...

  20. Attenuated total reflectance Fourier-transform infrared spectroscopic investigation of silicon heterojunction solar cells

    Czech Academy of Sciences Publication Activity Database

    Holovský, Jakub; De Wolf, S.; Jiříček, Petr; Ballif, C.

    2015-01-01

    Roč. 86, č. 7 (2015), "073108-1"-"073108-6". ISSN 0034-6748 R&D Projects: GA ČR(CZ) GA14-05053S; GA MŠk 7E12029; GA MŠk(CZ) LM2011026 EU Projects: European Commission(XE) 283501 - FAST TRACK Institutional support: RVO:68378271 Keywords : FTIR * ATR * solar cells Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.614, year: 2014

  1. Preliminary Method for Direct Quantification of Colistin Methanesulfonate by Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy

    OpenAIRE

    Niece, Krista L.; Akers, Kevin S.

    2015-01-01

    Colistin use has increased in response to the advent of infections caused by multidrug-resistant organisms. It is administered parenterally as an inactive prodrug, colistin methanesulfonate (CMS). Various formulations of CMS and labeling conventions can lead to confusion about colistin dosing, and questions remain about the pharmacokinetics of CMS. Since CMS does not have strong UV absorbance, current methods employ a laborious process of chemical conversion to colistin followed by precolumn ...

  2. Rapid identification and classification of Staphylococcus aureus by attenuated total reflectance fourier transform infrared spectroscopy

    Science.gov (United States)

    Staphylococcus aureus is an important bacterium that can cause serious infections in humans such as pneumonia and bacteremia. Rapid detection of this pathogen is crucial in food industries and clinical laboratories to control S. aureus food poisoning and human infections. In this study, fourier tran...

  3. An Attenuated Total Reflectance Sensor for Copper: An Experiment for Analytical or Physical Chemistry

    Science.gov (United States)

    Shtoyko, Tanya; Zudans, Imants; Seliskar, Carl J.; Heineman, William R.; Richardson, John N.

    2004-01-01

    A sensor experiment which can be applied to advanced undergraduate laboratory course in physical or analytical chemistry is described along with certain concepts like the demonstration of chemical sensing, preparation of thin films on a substrate, microtitration, optical determination of complex ion stoichiometry and isosbestic point. It is seen…

  4. Correcting attenuated total reflection-fourier transform infrared spectra for water vapor and carbon dioxide

    DEFF Research Database (Denmark)

    Bruun, Susanne Wrang; Kohler, Achim; Adt, Isabelle;

    2006-01-01

    . albicans) growing on an ATR crystal, respectively). The amounts of the atmospheric gases as expressed by the model spectra were estimated by regression, using second-derivative transformed spectra, and the estimated gas spectra could subsequently be subtracted from the sample spectra. For spectra of the...

  5. ATTENUATED TOTAL REFLECTANCE-FOURIER-TRANSFORM INFRARED MICROSPECTROSCOPY A RAPID METHOD FOR MICROBIAL STRAIN CHARACTERIZATION

    Directory of Open Access Journals (Sweden)

    Meshref Awad Alruwaili

    2013-01-01

    Full Text Available Fourier-Transform Infrared (FTIR spectroscopy and BHI 50CH were used to identify bacteria of the Lactobacillus (L. at the species level. A previously developed method for measuring FTIR spectra and a strategy for their analysis provided the basis for selecting the FTIR spectra of reference bacterial strains and created a spectral library. The research was launched in which the spectra collected in the above library were used for developing a spectral reference for known reference bacterial strains and the practical value of the generated library was verified based on the results of identification of four bacterial strains viz. L. plantarum, L. casei, L. lactis and L. fermentum of known taxonomy as well as identification of 15 bacterial strains isolated from rumen extracts and identified on the basis of their taxonomy and biochemical tests. The application of prepared lactic acid bacteria reference library for analysis of advanced analysis of FTIR was provided an accurate identification of 90% of bacterial strains of the genus Lactic acid bacteria identified by FTIR-microspectroscopy.

  6. Total reflection and cloaking by zero index metamaterials loaded with rectangular dielectric defects

    KAUST Repository

    Wu, Ying

    2013-05-06

    In this work, we investigate wave transmission property through a zero index metamaterial (ZIM) waveguide embedded with rectangular dielectric defects. We show that total reflection and total transmission (cloaking) can be achieved by adjusting the geometric sizes and/or permittivities of the defects. Our work provides another possibility of manipulating wave propagation through ZIM in addition to the widely studied dielectric defects with cylindrical geometries.

  7. Optical Waveguide Switches Employing Total-Internal-Reflection (TIR) Effect (Invited Paper)

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    In this paper, our recent research work on the total-internal-reflection optical switch is presented. The thermo-optic effect of polymeric materials and the photon-induced carrier effect of GaAlAs/GaAs are used in our devices.

  8. Total internal reflection fluorescence microscopy imaging-guided confocal single-molecule fluorescence spectroscopy

    OpenAIRE

    Zheng, Desheng; Kaldaras, Leonora; Lu, H. Peter

    2012-01-01

    We have developed an integrated spectroscopy system combining total internal reflection fluorescence microscopy imaging with confocal single-molecule fluorescence spectroscopy for two-dimensional interfaces. This spectroscopy approach is capable of both multiple molecules simultaneously sampling and in situ confocal fluorescence dynamics analyses of individual molecules of interest. We have demonstrated the calibration with fluorescent microspheres, and carried out single-molecule spectroscop...

  9. Super hydrophobic surface of polytetrafluoroethylene fabricated by picosecond laser and phenomenon of total internal reflection underwater

    Science.gov (United States)

    Jiang, Yijian; Cao, Wenshen; Zhao, Yan; Wu, Yan; Ji, Lingfei

    2015-03-01

    A groove-shaped array with average 25 μm interval, 25 μm wall thickness, 75 μm depth and a columnar array with average 30 μm side length, 25 μm interval, 43 μm depth are processed by 1064 nm picosecond laser on polytetrafluoroethylene (PTFE) surface at room temperature. The water contact angle of modified PTFE surface can reach 167°, which show super hydrophobic surface of PTFE is prepared. It is observed super hydrophobic surface reflects metal luster underwater through the glassware when super hydrophobic PTFE entirely immerses in pure water. The experiment conducts super hydrophobic surface will enhance intensity of reflection of visible light underwater, which is due to total internal reflection of super hydrophobic surface und erwater.

  10. Characterization of structure of surface and interface of matter using X-ray total reflection phenomenon

    International Nuclear Information System (INIS)

    A total reflection x-ray surface analysis makes possible to practice the structure analysis of surface of matter under the atmosphere. In this paper, the principle, equipments and the examples of measurements are explained. As the application of new X-ray structure analysis method, the determination of very accurate surface number density by the anomalous grazing X-ray reflectometry (AGXR) developed by us and the X-ray scattering apparatus to study the surface and interface of liquid are explained. The number densities of Cr and Fe atom in the passive film on the surface of stainless steel are 11.8 ± 0.4 and 7.4 ± 0.3 atoms/nm3, respectively. The reflection curve of water/mercury interface can be measured and the difference of reflectance from that of the free surface of mercury was found. (J.P.N.)

  11. Fabrication and evaluation of high-precision total-reflection mirrors for coherent X-rays

    International Nuclear Information System (INIS)

    Ultrahigh figure accuracy and atomic smoothness will be required for the surfaces of X-ray total-reflection mirrors with the realization of coherent X-rays at 3rd and upcoming 4th generation synchrotron facilities. In this study, we report the application of EEM (Elastic Emission Machining) and PCVM (Plasma Chemical Vaporization Machining) being newly developed ultraprecision machining methods to the fabrication of high-quality total-reflection mirrors for use in advanced X-ray instruments, the evaluation of the fabricated minors at the 1 km-long beamline of SPring-8 (BL29XUL) having the highest degree of coherency, and the world-record performance of the mirrors in the focusing of hard X-rays. (author)

  12. Total reflection X-Ray Fluorescence in medicine. Technique and applications

    International Nuclear Information System (INIS)

    The developments Total reflection X-Ray Fluorescence techniques is make the method appropriate for sample, accurate and precise analysis of heavy element in organic fluid and tissue in health related and pollutions problems, Application include analysis as an advantageous aid in drug synthesis and characterization, trace elements determination in amniotic fluid in fetus malformation studies, analysis of brain specimens and cerebrospinal fluid in central nervous system disorders, the influence of trace elements in cataract genesis and blood, body fluids and tissue drug level- monitoring. Accuracy, precision and detection limits attained in the analysis of platinum in minute amounts of serum from oncological pediatric patients undergoing chemotherapy which Pt-containing drugs shows Total reflection X-Ray Fluorescence could be used for routine analysis as an aid in clinical practice

  13. Design of plasmonic nano-antenna for total internal reflection fluorescence microscopy.

    Science.gov (United States)

    Lee, Eun-Khwang; Song, Jung-Hwan; Jeong, Kwang-Yong; Seo, Min-Kyo

    2013-10-01

    We propose a gold modified bow-tie plasmonic nano-antenna, which can be suitably used in combination with total internal reflection fluorescence microscopy. The plasmonic nano-antenna, supporting well-separated multiple resonances, not only concentrates the total internal reflection evanescent field at the deep subwavelength scale, but also enhances fluorescence emission by the Purcell effect. Finite-difference time-domain computations show that the enhancement of the excitation light strongly correlates with the far-field radiation pattern radiated from the antenna. Depending on the antenna geometry, the resonant modes are widely tuned and their wavelengths can be easily matched to the diverse emission or excitation wavelengths of fluorophores. PMID:24104219

  14. Development and state of total reflection X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Since the first application of total reflection in X-ray fluorescence analysis at the beginning of the 1970's this method has been subject to continual modifications and improvements and has frequently competed with NAA, ICP and AAS as a micro-analysis process for traces in the nanogram and picogram range. A survey is given of the many applications published in the literature, particularly of applications in environmental research practised at the GKSS Research Centre. (RB)

  15. Investigation And Application Of The Frustrated-Total-Internal-Reflection Phenomenon in Optical Fibers

    OpenAIRE

    Rahnavardy, K.; Arya, Vivek; Wang, A.; Weiss, J.M.

    1997-01-01

    A detailed investigation of the frustrated-total-internal-reflection (FTIR) phenomenon in silica-glass-based optical fibers and its application to simple intensity-modulated strain and pressure sensors is presented. Such sensors may be readily fabricated with silica-based fibers and can be easily modified with sapphire fibers for high-temperature industrial applications where conventional silica-based fiber sensors are not feasible. We present the all-fiber FTIR sensor and show good correlati...

  16. Variable-angle total internal reflection fluorescence microscopy of intact cells of Arabidopsis thaliana

    OpenAIRE

    Kim Myung K; Hao Huaiqin; Fan Lusheng; Ash William M; Wan Yinglang; Lin Jinxing

    2011-01-01

    Abstract Background Total internal reflection fluorescence microscopy (TIRFM) is a powerful tool for observing fluorescently labeled molecules on the plasma membrane surface of animal cells. However, the utility of TIRFM in plant cell studies has been limited by the fact that plants have cell walls, thick peripheral layers surrounding the plasma membrane. Recently, a new technique known as variable-angle epifluorescence microscopy (VAEM) was developed to circumvent this problem. However, the ...

  17. Efficient optical path folding by using multiple total internal reflections in a microcavity

    CERN Document Server

    Shinohara, Susumu; Fukushima, Takehiro; Harayama, Takahisa; Arai, Kenichi; Yoshimura, Kazuyuki

    2014-01-01

    We propose using an asymmetric resonant microcavity for the efficient generation of an optical path that is much longer than the diameter of the cavity. The path is formed along a star polygonal periodic orbit within the cavity, which is stable and confined by total internal reflection. We fabricated a semiconductor device based on this idea with an average diameter of 0.3 mm, and achieved a path length of 2.79 mm experimentally.

  18. TX 2000: total reflection and 45o energy dispersive x-ray fluorescence spectrometer

    International Nuclear Information System (INIS)

    This equipment, developed by Ital Structures, combines two kinds of energy dispersive X-ray fluorescence techniques, the first using total reflection geometry and the second conventional 45o geometry. The equipment is completely controlled by a PC and to reach the condition of total reflection is very easy because it is enough to load the file with the right position for the corresponding energy. In this apparatus we used an x-ray tube with an alloy anode of Mo/W with a long fine focus at 2200 W. To monochromatize the x-ray beam while choosing, for example, the Mo K alpha or W L alpha or a piece of white spectrum of 33 keV, we use a highly reflective multilayer made of Si/W with 2d = 45.5 Ao. The detector used in the equipment is a lithium drifted silicon detector (Si(Li)) with an excellent energy resolution of 135 eV at 5.9 keV and 1000 cps. We developed two programs written in Windows 95, 98 and NT for a 32 bit microprocessor. The first one is called TYACQ32 and has the following functions: first, complete control of the hardware, second automatic alignment of the TX 2000 spectrometer and third acquisition of spectra. The second program is EDXRF32. This is a program to accomplish spectrum and quantitative analysis for TXRF and EDXRF 45o degrees analysis. (author)

  19. Development of thin-film total-reflection mirrors for the XUV FEL

    Science.gov (United States)

    Jacobi, Sandra; Wiesmann, Joerg; Steeg, Barbara; Feldhaus, Josef; Michaelsen, Carsten

    2001-12-01

    A free electron laser for the XUV spectral range is currently under test at the TESLA Test Facility at DESY. High gain has been demonstrated below 100nm wavelength, and it is expected that the FEL will provide intense, sub-picosecond radiation pulses with photon energies up to 200eV. Thin film optical elements required for this facility are currently being developed by the X-ray optics group of the GKSS research center near Hamburg. Sputter-deposited coatings have been prepared for the use as total reflection X-ray mirrors for FEL beam optics. Coatings of low Z elements with the lowest possible absorption and high reflectivity have been investigated. Silicon substrates have been coated with carbon using different deposition conditions. The films were investigated using the soft X-ray reflectometer at the HASYLAB beamline G1. The measurements show that the reflectivity of the films is typically 90% at energies below 200eV and a grazing incidence angle of 4 degrees. The optical constants of these coatings obtained from the reflectivity measurements and are in agreement with tabulated values. The deposition parameters have been optimized resulting in argon contamination free films with near-theoretical performance. Preliminary investigations concerning the heat resistance of the films were also carried out.

  20. Total-internal-reflection-based photomask for large-area photolithography

    Science.gov (United States)

    Hung, Shao-Kang; Lin, Kung-Hsuan; Chen, Cheng-Lung; Chou, Chen-Hsun; Lin, You-Chuan

    2016-05-01

    Photolithography has been widely implemented with a photomask in contact or in close proximity to the photoresist layer. The flatness of the substrates is a crucial factor to guarantee the quality of the entire patterned photoresist (PR) layer especially for large-area photolithography. However, some substrates, such as sapphire wafers, do not possess highly uniform thickness as silicon wafer does. In this work, we demonstrate that a flexible polydimethylsiloxane (PDMS) photomask with optical total-internal-reflection structure can effectively circumvent this problem for mass production. Different from conventional photomask that the light is blocked by the patterned reflective/absorbing materials, the distributions of light intensity on the PR is engineered by the geometric structure of the transparent PDMS photomask. We demonstrate that 4 in. patterned sapphire wafers can be successfully fabricated by using this PDMS photomask, which can be easily integrated into the present techniques in industry for mass production of substrates for GaN-based optoelectronic devices.

  1. Bromine and bromide content in soils: Analytical approach from total reflection X-ray fluorescence spectrometry.

    Science.gov (United States)

    Gallardo, Helena; Queralt, Ignasi; Tapias, Josefina; Candela, Lucila; Margui, Eva

    2016-08-01

    Monitoring total bromine and bromide concentrations in soils is significant in many environmental studies. Thus fast analytical methodologies that entail simple sample preparation and low-cost analyses are desired. In the present work, the possibilities and drawbacks of low-power total reflection X-ray fluorescence spectrometry (TXRF) for the determination of total bromine and bromide contents in soils were evaluated. The direct analysis of a solid suspension using 20 mg of fine ground soil (water soil extracts. In this case, the TXRF analysis can be directly performed by depositing 10 μL of the internal standardized soil extract sample on a quartz glass reflector in a measuring time of 1500 s. The bromide limit of detection by this approach was 10 μg L(-1). Good agreement was obtained between the TXRF results for the total bromine and bromide determinations in soils and those obtained by other popular analytical techniques, e.g. energy dispersive X-ray fluorescence spectrometry (total bromine) and ionic chromatography (bromide). As a study case, the TXRF method was applied to study bromine accumulation in two agricultural soils fumigated with a methyl bromide pesticide and irrigated with regenerated waste water. PMID:27179429

  2. Theory of frustrated total internal reflection: Superluminal singularities of optical waveguides

    International Nuclear Information System (INIS)

    Classical approach to frustrated total internal reflection (FTIR) does not describe its temporal properties, that are additionally considered and their superluminal singularity is shown. The transition to quantum electrodynamics shows that momenta of photons are reduced at FTIR relative to energy, i.e. it is the tunnel process, the nonlocal manifestation of near field. The tunneling consists in the instantaneous jump of excitations (virtual photons) onto definite distance, and can be described by equation having certain instanton features. Thus, the possibility of signal transfer with superluminal group velocity via optical fibers is substantiated that conforms to certain supervisions. Such properties of FTIR near field may explain, in principle, some other observed phenomena

  3. Study of the interaction between HSA and oligo-DNA using total internal reflection ellipsometry

    Science.gov (United States)

    Jung, Y. W.; Byun, J. S.; Kim, Y. D.; Hemzal, D.; Humliček, J.

    2012-04-01

    Techniques of quantitative analysis are very important for studies of the interactions between bio-molecules in the field of biotechnology and drug development. The total internal reflection ellipsometry system (TIRE) is an attractive label-free procedure for the quantitative analysis of biomolecules because it combines the analytic ability of ellipsometry and the high surface sensitivity of surface plasmon resonance. In this work, we have used TIRE to study the optical properties of an aquatic monolayer of human serum albumin (HSA) and oligo-DNA. Also, we have monitored the adsorption and the interaction processes of protein layers.

  4. Integrated optic polarization splitter based on total internal reflection from a birefringent polymer.

    Science.gov (United States)

    Huang, Guanghao; Park, Tae-Hyun; Chu, Woo-Sung; Oh, Min-Cheol

    2016-09-01

    An integrated optic polarization splitter with large fabrication tolerance and high reliability is required for optical signal processing in quantum-encrypted communication systems. A polarization splitter based on total internal reflection from a highly birefringent polymer-reactive mesogen-is proposed and demonstrated in this work. The device consists of a mode expander for reducing the wave vector distribution of the guided mode, and an interface with a large birefringence. Several polymers with suitable refractive indexes were used for fabricating the device. We obtained a polarization splitter with a low crosstalk (less than -30 dB), and a large fabrication tolerance. PMID:27607704

  5. Microplate-compatible total internal reflection fluorescence microscopy for receptor pharmacology

    Science.gov (United States)

    Chen, Minghan; Zaytseva, Natalya V.; Wu, Qi; Li, Min; Fang, Ye

    2013-05-01

    We report the use of total internal reflection fluorescence (TIRF) microscopy for analyzing receptor pharmacology and the development of a microplate-compatible TIRF imaging system. Using stably expressed green fluorescence protein tagged β2-adrenergic receptor as the reporter, we found that the activation of different receptors results in distinct kinetic signatures of the TIRF intensity of cells. These TIRF signatures closely resemble the characteristics of their respective label-free dynamic mass redistribution signals in the same cells. This suggests that TIRF in microplate can be used for profiling and screening drugs.

  6. Synchrotron total reflection X-ray fluorescence at BL-16 microfocus beamline of Indus-2

    Energy Technology Data Exchange (ETDEWEB)

    Tiwari, M. K., E-mail: mktiwari@rrcat.gov.in; Singh, A. K., E-mail: mktiwari@rrcat.gov.in; Das, Gangadhar, E-mail: mktiwari@rrcat.gov.in; Chowdhury, Anupam, E-mail: mktiwari@rrcat.gov.in; Lodha, G. S., E-mail: mktiwari@rrcat.gov.in [Indus Synchrotrons Utilisation Division, Raja Ramanna Centre for Advanced Technology, Indore-452013 (India)

    2014-04-24

    Determination of ultra trace elements is important in many disciplines both in basic and applied sciences. Numerous applications show their importance in medical science, environmental science, materials science, food processing and semiconductor industries and in maintaining the quality control of ultra pure chemicals and reagents. We report commissioning of a synchrotron based total reflection x-ray fluorescence (TXRF) facility on the BL-16 microfocus beamline of Indus-2. This paper describes the performance of the BL-16 TXRF spectrometer and the detailed description of its capabilities through examples of measured results.

  7. Synchrotron total reflection X-ray fluorescence at BL-16 microfocus beamline of Indus-2

    International Nuclear Information System (INIS)

    Determination of ultra trace elements is important in many disciplines both in basic and applied sciences. Numerous applications show their importance in medical science, environmental science, materials science, food processing and semiconductor industries and in maintaining the quality control of ultra pure chemicals and reagents. We report commissioning of a synchrotron based total reflection x-ray fluorescence (TXRF) facility on the BL-16 microfocus beamline of Indus-2. This paper describes the performance of the BL-16 TXRF spectrometer and the detailed description of its capabilities through examples of measured results

  8. Langmuir monolayers on water surface investigated by X-ray total reflection fluorescence

    International Nuclear Information System (INIS)

    Langmuir monolayers of metal-rich phthalocyanines (Pc) and phospholipid at air/water interface have been studied by X-ray total reflection fluorescence at SR beam line ID 10B (ESRF). Experimental fluorescence angular dependences from 'heavy' ions of a monolayer alone on water surface modulated by evanescent wave/X-ray standing wave pattern have been detected for the first time, are in good agreement with calculations and provide information about the position of metal ions in organic molecule with respect to water surface

  9. Langmuir monolayers on water surface investigated by X-ray total reflection fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Zheludeva, S.I.; Novikova, N.N.; Konovalov, O.V.; Kovalchuk, M.V.; Stepina, N.D.; Tereschenko, E.Yu

    2003-10-15

    Langmuir monolayers of metal-rich phthalocyanines (Pc) and phospholipid at air/water interface have been studied by X-ray total reflection fluorescence at SR beam line ID 10B (ESRF). Experimental fluorescence angular dependences from 'heavy' ions of a monolayer alone on water surface modulated by evanescent wave/X-ray standing wave pattern have been detected for the first time, are in good agreement with calculations and provide information about the position of metal ions in organic molecule with respect to water surface.

  10. Energy dispersive X-ray fluorescence analysis with multiple total reflection

    International Nuclear Information System (INIS)

    The development of a total reflection XRF analyzer and the performance data of this instrument are described. The drastic reduction of the scattered radiation is the outstanding property of the method. Detection limits of elements and matrix effects are discussed. The competition with other methods of analysis has proven its advantages in a wide range. In addition to its multi-element features down to the picogram level, particularly its universal calibration function has turned out to be a great help in the analytical practice. (orig./RB)

  11. Clinical applications of total reflection X-Ray Fluorescence in the treatment of cancer, Preliminary results

    International Nuclear Information System (INIS)

    A simple procedure is presents in which direct irradiation of small (10 ?l) quantities of blood serum, without chemical treatment or internal standard addition, allows reliable quantification of the PT plasma level with a 300 ppb detection limit and precision of 7% (n=7) It is shown that the method allows determination of the time evolution of the drug concentration and the drug half life in the patient the results indicated the viability of an improvement in the clinical practice of chemotherapy by the routine analysis of platinum with total reflection X-Ray Fluorescence

  12. Frustrated total internal reflection and critical coupling in a thick plasmonic grating with narrow slits

    International Nuclear Information System (INIS)

    We demonstrate the possibility of critical coupling through frustrated total internal reflection in a thick plasmonic grating below the first diffraction order. Differently from conventional approaches relying on the excitation of surface plasmon-polaritons, here we exploit the light coupling with the leaky modes supported by the grating. This mechanism entails a wide-angle coupling and effectively access spectral bands that would otherwise be difficult to probe using conventional plasmonic critical coupling techniques, such as the Otto configuration. Our finding may pave the way to efficient plasmonic bio-sensor devices.

  13. The effect of surface texture on total reflection of neutrons and X-rays from modified interfaces

    DEFF Research Database (Denmark)

    Goldar, A.; Roser, S.J.; Hughes, A.; Edler, K.; Gerstenberg, M.C.

    2002-01-01

    X-ray and neutron scattering from macroscopically rough surfaces and interfaces is considered and a new method of analysis based on the variation of the shape of the total reflection edge in the reflectivity profile is proposed. It was shown that in the limit that the correlation length and the...... height of the surface roughness are larger than the wavelength (at least 100 times bigger) of the incoming beam, the total reflection edge in the reflection profile becomes rounded. This technique allows direct analysis of the variation of the reflectivity pro le in terms of the structure of the surface...

  14. Total Glucosides of Danggui Buxue Tang Attenuate BLM-Induced Pulmonary Fibrosis via Regulating Oxidative Stress by Inhibiting NOX4

    Directory of Open Access Journals (Sweden)

    Ping Zhao

    2015-01-01

    Full Text Available Pulmonary fibrosis (PF is a serious chronic lung disease with unknown pathogenesis. Researches have confirmed that oxidative stress which is regulated by NADPH oxidase-4 (NOX4, a main source of reactive oxygen species (ROS, is an important molecular mechanism underlying PF. Previous studies showed that total glucosides of Danggui Buxue Tang (DBTG, an extract from a classical traditional Chinese herbal formula, Danggui Buxue Tang (DBT, attenuated bleomycin-induced PF in rats. However, the mechanisms of DBTG are still not clear. We hypothesize that DBTG attenuates PF through regulating the level of oxidative stress by inhibiting NOX4. And we found that fibrosis indexes hydroxyproline (HYP and type I collagen (Col-I were lower in DBTG groups compared with the model group. In addition, the expression of transforming growth factor-β1 (TGF-β1 and expression of alpha smooth muscle actin (α-SMA were also much more decreased than the model group. For oxidative stress indicators, DBTG blunted the decrease of superoxide dismutase (SOD activity, total antioxidant capacity (T-AOC, and the increase in malondialdehyde (MDA, 8-iso-prostaglandin in lung homogenates. Treatment with DBTG restrained the expression of NOX4 compared to the model group. Present study confirms that DBTG inhibits BLM-induced PF by modulating the level of oxidative stress via suppressing NOX4.

  15. Determination of total mass attenuation coefficients, effective atomic numbers and electron densities for different shielding materials used in radiation protection

    Energy Technology Data Exchange (ETDEWEB)

    Almeida J, A. T. [FUNDACENTRO, Centro Regional de Minas Gerais, Brazilian Institute for Safety and Health at Work, Belo Horizonte, 30180-100 Minas Gerais (Brazil); Nogueira, M. S. [Center of Development of Nuclear Technology / CNEN, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil); Santos, M. A. P., E-mail: mnogue@cdtn.br [Regional Center for Nuclear Science / CNEN, 50.740-540 Recife, Pernambuco (Brazil)

    2015-10-15

    Full text: In this paper, the interaction of X-rays with some shielding materials has been studied for materials containing different amounts of barite and aggregates. The total mass attenuation coefficient (μ{sub t}) for three shielding materials has been calculated by using WinXCOM program in the energy range from RQR qualities (RQR-4, RQR-6, RQR-9, and RQR-10). They were: cream barite (density 2.99 g/cm{sup 3} collected in the State of Sao Paulo), purple barite (density 2.95 g/cm{sup 3} collected in the State of Bahia) and white barite (density 3.10 g/cm{sup 3} collected in the State of Paraiba). The chemical analysis was carried out by an X-ray fluorescence spectrometer model EDX-720, through dispersive energy. The six elements of the higher concentration found in the sample and analyzed by Spectrophotometry of Energy Dispersive X-ray for the samples were Ba(60.9% - white barite), Ca(17,92% - cream barite), Ce(3,60% - white barite), Fe(17,16% - purple barite), S(12,11% - white barite) and Si(29,61% - purple barite). Also, the effective atomic number (Z{sub eff}) and the effective electron density (N{sub eff}) were calculated using the values of the total mass attenuation coefficient. The dependence of these parameters on the incident photon energy and the chemical composition has been examined. (Author)

  16. Determination of total mass attenuation coefficients, effective atomic numbers and electron densities for different shielding materials used in radiation protection

    International Nuclear Information System (INIS)

    Full text: In this paper, the interaction of X-rays with some shielding materials has been studied for materials containing different amounts of barite and aggregates. The total mass attenuation coefficient (μt) for three shielding materials has been calculated by using WinXCOM program in the energy range from RQR qualities (RQR-4, RQR-6, RQR-9, and RQR-10). They were: cream barite (density 2.99 g/cm3 collected in the State of Sao Paulo), purple barite (density 2.95 g/cm3 collected in the State of Bahia) and white barite (density 3.10 g/cm3 collected in the State of Paraiba). The chemical analysis was carried out by an X-ray fluorescence spectrometer model EDX-720, through dispersive energy. The six elements of the higher concentration found in the sample and analyzed by Spectrophotometry of Energy Dispersive X-ray for the samples were Ba(60.9% - white barite), Ca(17,92% - cream barite), Ce(3,60% - white barite), Fe(17,16% - purple barite), S(12,11% - white barite) and Si(29,61% - purple barite). Also, the effective atomic number (Zeff) and the effective electron density (Neff) were calculated using the values of the total mass attenuation coefficient. The dependence of these parameters on the incident photon energy and the chemical composition has been examined. (Author)

  17. Direct elemental analysis of cancer cell lines by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    The elemental content of Cu, Fe and Zn in two human adenocarcinoma cell lines was investigated by total reflection X-ray fluorescence (TXRF) spectrometry. Cancer cells were sedimented directly to the quartz plates using a modified cytospin slide holder setup. Special glass stands and caps were also constructed to hold the quartz plates with the cells during the vapour-phase microwave assisted digestion. The method was validated by analysis of certified reference materials. The signal-to-noise ratio was optimized by washing the cells with different solutions. The technique was applied to the determination of Cu, Fe and Zn content of HT-29 and HCA-7 colorectal adenocarcinoma cell lines. Dry mass of the centrifuged cells were determined and the elemental analysis data reported for the two cell lines were referred either to cell numbers, to the total protein content or to the dry mass

  18. Total reflection coefficients of low-energy photons presented as universal functions

    International Nuclear Information System (INIS)

    The possibility of expressing the total particle and energy reflection coefficients of low-energy photons in the form of universal functions valid for different shielding materials is investigated in this paper. The analysis is based on the results of Monte Carlo simulations of photon reflection by using MCNP, FOTELP, and PENELOPE codes. The normal incidence of the narrow monoenergetic photon beam of the unit intensity and of initial energies from 20 keV up to 100 keV is considered, and particle and energy reflection coefficients from the plane homogenous targets of water, aluminum, and iron are determined and compared. The representations of albedo coefficients on the initial photon energy, on the probability of large-angle photon scattering, and on the mean number of photon scatterings are examined. It is found out that only the rescaled albedo coefficients dependent on the mean number of photon scatterings have the form of universal functions and these functions are determined by applying the least square method. (author)

  19. Variable-angle total internal reflection fluorescence microscopy of intact cells of Arabidopsis thaliana

    Directory of Open Access Journals (Sweden)

    Kim Myung K

    2011-09-01

    Full Text Available Abstract Background Total internal reflection fluorescence microscopy (TIRFM is a powerful tool for observing fluorescently labeled molecules on the plasma membrane surface of animal cells. However, the utility of TIRFM in plant cell studies has been limited by the fact that plants have cell walls, thick peripheral layers surrounding the plasma membrane. Recently, a new technique known as variable-angle epifluorescence microscopy (VAEM was developed to circumvent this problem. However, the lack of a detailed analysis of the optical principles underlying VAEM has limited its applications in plant-cell biology. Results Here, we present theoretical and experimental evidence supporting the use of variable-angle TIRFM in observations of intact plant cells. We show that when total internal reflection occurs at the cell wall/cytosol interface with an appropriate angle of incidence, an evanescent wave field of constant depth is produced inside the cytosol. Results of experimental TIRFM observations of the dynamic behaviors of phototropin 1 (a membrane receptor protein and clathrin light chain (a vesicle coat protein support our theoretical analysis. Conclusions These findings demonstrate that variable-angle TIRFM is appropriate for quantitative live imaging of cells in intact tissues of Arabidopsis thaliana.

  20. Small-Angle Measurement of Laser Beam Steering Based on Total Internal-Reflection Effect

    International Nuclear Information System (INIS)

    A precision small-angle measurement system is introduced based on optical total internal reflection effect. When the incident angle of a polarized beam is larger than the critical angle, and the beam has a small steering angle in the vicinity of the critical angle, the total internal reflection will take place and a relative phased shift between the s- and the p-polarized components is produced. By utilizing the characteristics we could measure the small angle displacement of the incident beam. A differential optical system including four right-angle prisms is set up based on above, and we take the difference of the interference intensity of sand p-components divided by their sum as the output signal. A good linearity between the output signal and the angular displacement is proved by the theoretical simulation. The system result and error analysis are given as well. The experiment shows that the measurement range of this system is ±20, and a resolution of 10'' is achieved. This method has many advantages, such as simple configuration, high sensitivity, good linearity and high antinoise ability

  1. Empirical versus theoretical calibration of a total reflection X-ray fluorescence spectrometer

    International Nuclear Information System (INIS)

    Total Reflection X-Ray Fluorescence Spectrometry (TXRF) is a well established technique for trace analysis. It has been developed in the last ten years, being applied in a wide range of analytical problems. Most of the literature regarding TXRF analysis for quantification reports the use of a relative sensitivity calibration curve. This means internal standardization is required with an element that is not present in the sample. In the present work the quantification of different samples was done by TXRF using two methods of calibration and calculation of the sensitivity factors: a) multielemental solutions were prepared and measured in the TXRF unit to calculate the relative sensitivity factors with respect to selenium chosen as reference; b) fundamental parameters for molybdenum excitation were taken from tables reported in the literature to calculate the sensitivities. Reference materials were analyzed to establish the adecuacy of both methods of calibration. It was concluded that the method of multielemental solutions is adecuate for quantification using a TXRF system. Due to the special excitation conditions in the total reflection geometry, the use of fundamental parameters reported in the literature cited is an incorrect procedure for TXRF calibration if direct gross radiation is applied to the samples (not filtered radiation) because the excitation beam is not monoenergetic. (author)

  2. Smooth and rough Proteus mirabilis lipopolysaccharides studied by total internal reflection ellipsometry

    Energy Technology Data Exchange (ETDEWEB)

    Gleńska-Olender, J., E-mail: joannaglenska@wp.pl [Institute of Biology, Jan Kochanowski University, 25-406 Kielce (Poland); Świętokrzyski Biobank, Regional Science and Technology Center, 26-060 Chęciny (Poland); Dworecki, K. [Institute of Physics, Jan Kochanowski University, 25-406 Kielce (Poland); Sęk, S. [Department of Chemistry, University of Warsaw, 02-093 Warsaw (Poland); Kwinkowski, M.; Kaca, W. [Institute of Biology, Jan Kochanowski University, 25-406 Kielce (Poland)

    2013-12-02

    Total internal reflection ellipsometry (TIRE), a label-free optical detection technique for studying interactions between biomolecules, was used to examine the adsorption of various forms of lipopolysaccharides (LPSs) isolated from Proteus mirabilis S1959, R110, and R45 strains on a gold surface. The thickness of the adsorbed layers was determined by TIRE, with the average values for S1959, R110, and R45 LPS layers being 78 ± 5, 39 ± 3, and 12 ± 2 nm, respectively. The thickness of LPS layers corresponds to the presence and length of O-specific parts in P. mirabilis LPS molecules. Atomic force microscopy was used as a complementary technique for visualizing lipopolysaccharides on the surface. Force measurements seem to confirm the data obtained from TIRE experiments. - Highlights: • Proteus mirabilis lipopolysaccharides were adsorbed on the gold surface. • Thickness of adsorbed layers was determined by total internal reflection ellipsometry. • Atomic force microscopy was used to visualize lipopolysaccharide build-up on gold surface. • Time is important in the evolution of biomolecular film thickness created on gold surface.

  3. Estimating soil total nitrogen contents from visible/near-infrared reflectance based on successive projections algorithm

    International Nuclear Information System (INIS)

    The Visible/near-infrared reflectance (Vis/NIR) spectroscopy combined with multiple regression methods have been employed to assess various soil properties quantitatively. However, useless or irrelevant information in some bands worsen the performances of the calibrated models. Successive projections algorithm (SPA) is an effective technique for selecting informative variables, and its application potential in estimating soil contents using visible/near-infrared reflectance (Vis/NIR) spectroscopy has not been explored. This paper aimed to explore the effect of SPA combined with support vector machine regression (SVMR) on soil total nitrogen (TN) contents estimation using Vis/NIR spectroscopy. For this purpose, SPA-SVMR was compared with full spectrum based SVMR (FS-SVMR) for soil total nitrogen (TN) estimation, respectively. The results showed that the SPA-SVMR model (R2v = 0.58, RMSEV = 0.364) performed better than the FS-SVMR model (R2v = 0.49, RMSEV = 0.394). We concluded that the SPA could eliminate the uninformative variables and improve the performance of SVMR on estimating TN contents. In further study, using the SPA-SVMR method to estimate other soil properties is necessary to test this finding

  4. Smooth and rough Proteus mirabilis lipopolysaccharides studied by total internal reflection ellipsometry

    International Nuclear Information System (INIS)

    Total internal reflection ellipsometry (TIRE), a label-free optical detection technique for studying interactions between biomolecules, was used to examine the adsorption of various forms of lipopolysaccharides (LPSs) isolated from Proteus mirabilis S1959, R110, and R45 strains on a gold surface. The thickness of the adsorbed layers was determined by TIRE, with the average values for S1959, R110, and R45 LPS layers being 78 ± 5, 39 ± 3, and 12 ± 2 nm, respectively. The thickness of LPS layers corresponds to the presence and length of O-specific parts in P. mirabilis LPS molecules. Atomic force microscopy was used as a complementary technique for visualizing lipopolysaccharides on the surface. Force measurements seem to confirm the data obtained from TIRE experiments. - Highlights: • Proteus mirabilis lipopolysaccharides were adsorbed on the gold surface. • Thickness of adsorbed layers was determined by total internal reflection ellipsometry. • Atomic force microscopy was used to visualize lipopolysaccharide build-up on gold surface. • Time is important in the evolution of biomolecular film thickness created on gold surface

  5. Characterization of amorphous carbon films as total-reflection mirrors for XUV free-electron lasers

    Science.gov (United States)

    Jacobi, Sandra; Steeg, Barbara; Wiesmann, Jorg; Stormer, Michael; Feldhaus, Josef; Bormann, R.'diger; Michaelsen, Carsten

    2002-12-01

    As part of the TESLA (TeV-Energy Superconducting Linear Accelerator) project a free electron laser (FEL) in the XUV (Extreme Ultra-Violet, (6-200 eV)) and X-ray (0.5-15 keV) range is being developed at DESY (Deutsches Elektronen Synchrotron, Hamburg). At the TESLA Test Facility (TTF) a prototype FEL has recently demonstrated maximum light amplification in the range of 80 nm to 120 nm. It is expected that the FEL will provide intense, sub-picosecond radiation pulses with photon energies up to 200 eV in the next development stage. In a joint project between DESY and GKSS, thin film optical elements with very high radiation stability, as required for FEL applications, are currently being developed. Sputter-deposited amorphous carbon coatings have been prepared for use as total reflection X-ray mirrors. The optical characterization of the mirrors has been carried out using the soft X-ray reflectometer at HASYLAB (Hamburger Synchrotronstrahlungslabor) beamline G1. The reflectivity of the carbon films at 2 deg incidence angle is close to the theoretical reflectivity of 95.6 %, demonstrating the high quality of the coatings. For comparison, layers produced by different methods (e.g. Chemical vapor deposition, Pulsed laser deposition) have been characterized as well. Annealing experiments have been performed to evaluate the thermal stability of the amorphous carbon films. Further investigations concerning the radiation stability of the X-ray mirrors have also been conducted. The mirrors were irradiated in the FELIS (Free Electron Laser-Interaction with Solids) experiment at the TTF-FEL. Microscopic investigations demonstrate that the carbon mirrors are fairly stable.

  6. Redistribution of fluorescent molecules at the solid/liquid interface with total internal reflection illumination.

    Science.gov (United States)

    Wei, Lin; Ye, Zhongju; Luo, Wenjuan; Chen, Bo; Xiao, Lehui

    2016-08-01

    Many intriguing physical and chemical processes commonly take place at the solid/liquid interface. Total internal reflection illumination, together with single molecule spectroscopy, provides a robust platform for the selective exploration of kinetic processes close the interface. With these techniques, it was observed that the distribution of Rhodamine B molecules close to a solid/liquid interface could be regulated in a photo-induced route. The laser-induced repulsion force at this interface is enough to compromise the Brownian diffusion of single molecules in a range of several hundred nanometers normal to the solid/liquid interface. This observation is fundamentally and practically interesting because moderate laser intensity is enough to initiate this repulsion effect. Therefore, it might display extensive applications in the development of photo-modulation technique with high throughput capability. PMID:27216678

  7. Goos-H\\"anchen shifts in frustrated total internal reflection studied with wave packet propagation

    CERN Document Server

    Chen, Xi; Wei, Rong-Rong; Zhang, Yan

    2009-01-01

    We have investigated that the Goos-H\\"anchen (GH) shifts in frustrated total internal reflection (FTIR) studied with wave packet propagation. In the first-order approximation of the transmission coefficient, the GH shift is exactly the expression given by stationary phase method, thus saturates an asymptotic constant in two different ways depending on the angle of incidence. Taking account into the second-order approximation, the GH shift always depends on the width of the air gap due to the modification of the beam width. It is further shown that the GH shift with second-order correction increases with decreasing the beam width at the small incidence angles, while for the large incidence angles it reveals a strong decrease with decreasing the beam width. These phenomena offers the better understanding of the tunneling delay time in FTIR.

  8. Watch your step! A frustrated total internal reflection approach to forensic footwear imaging

    Science.gov (United States)

    Needham, J. A.; Sharp, J. S.

    2016-02-01

    Forensic image retrieval and processing are vital tools in the fight against crime e.g. during fingerprint capture. However, despite recent advances in machine vision technology and image processing techniques (and contrary to the claims of popular fiction) forensic image retrieval is still widely being performed using outdated practices involving inkpads and paper. Ongoing changes in government policy, increasing crime rates and the reduction of forensic service budgets increasingly require that evidence be gathered and processed more rapidly and efficiently. A consequence of this is that new, low-cost imaging technologies are required to simultaneously increase the quality and throughput of the processing of evidence. This is particularly true in the burgeoning field of forensic footwear analysis, where images of shoe prints are being used to link individuals to crime scenes. Here we describe one such approach based upon frustrated total internal reflection imaging that can be used to acquire images of regions where shoes contact rigid surfaces.

  9. Total reflection X-ray fluorescence analysis of airborne particulate matter

    Energy Technology Data Exchange (ETDEWEB)

    Klockenkaemper, R.; Bayer, H.; Bohlen, A. von [Institut fuer Spektrochemie und Angewandte Spektroskopie, Dortmund (Germany)

    1995-03-01

    The collection of air dust by a `Berner`- and a `Battelle`-impactor was adapted to the subsequent analysis by Total reflection X-Ray Fluorescence (TXRF). A suitable impactor material has to be chosen in order to avoid high blank values, collection losses and memory effects. Stainless steel even coated by TiN is not at all suitable. Titanium and aluminium are less favourable than makrolon or another high polymer which may even be antistatic. Small sampling volumes of only 1 m{sup 3} and short sampling times of about 1 h are sufficient for a multielement analysis by TXRF. Low detection limits of ng/m{sup 3} and a repeatability of some % can be realized. (author).

  10. Observation of Insulin Exocytosis by a Pancreatic (3 Cell Line with Total Internal Reflection Fluorescence Microscopy

    Institute of Scientific and Technical Information of China (English)

    Zhao-ying Fu; Ya-ping Wang; Yu Chen

    2011-01-01

    @@ INSULIN secretion was traditionally measured with biochemical and immunological methods such as enzyme linked immunosorbant assay and radio-immunoassay.However,these methods can only tell the amount of insulin secreted; they give no information about the secretion process or mechanism of exocytosis.In recent years,an imaging technique known as total internal reflection fluorescence (TIRF) microscopy has been employed to study insulin secretion.1-4 This imaging technique can explore events taking place near or on live cell membrane,such as secretory granule movement,exocytosis,vesicle content release,and membrane fusion.5-10 In the present paper,we applied TIRF microscopy to the observation of insulin exocytosis by the pancreatic β cell line Ins-1.

  11. Colouration of medieval glass bracelets studied by total reflection x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    The contents of 3d-transition metals (Ti, V, Cr, Mn, Fe, Co, Ni, Cu and Zn) in fragments of medieval glass bracelets, found in the necropolis of Stambolovo and the castle of Mezek, Bulgaria, were determined by total reflection X-ray fluorescence (TXRF) analysis using gallium as internal standard. The samples were analysed as slurries in Triton X 114. The experimental parameters: grain size of the glass sample, concentrations of glass sample, Triton X114 and internal standard in the slurry, volume of the slurry aliquot taken for analysis, as well as the excitation time, were optimised. For method validation the certified reference material BAM-S005 Type A soda-lime glass was used. It was proven that the elements Co, Mn and Fe are responsible for colour generation in the investigated glass samples. The precision of the determinations is characterised by an RSD in the range 3–11%

  12. Metals determination in coffee sample by total reflection X-ray fluorescence analysis (TXRF)

    International Nuclear Information System (INIS)

    The objective of this study was to evaluate the inorganic concentration in five brands of coffee, three of them nationally marketed and the others of an exportation kind. The samples were prepared by infusion with deionized water. To carry out the calibration, standard solutions were prepared with different concentrations of Al, Si, K, Ca, Ti, Cr, Fe, Ni, Zn and Se. The measurements were carried out using a white beam of synchrotron radiation for excitation and a Si (Li) semiconductor detector for detection. By employing Synchrotron Radiation Total Reflection X-Ray Fluorescence Analysis (SR-TXRF) it was possible to evaluate the concentrations of P, S, Cl, K, Ca, Mn, Fe, Cu, Zn, Rb and Ba. The detection limits for 300 s counting time were in the range of 0.03 (Ca) to 30 ng.g-1 (Rb), respectively. (author)

  13. First Total Reflection X-Ray Fluorescence round-robin test of water samples: Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Borgese, Laura; Bilo, Fabjola [Chemistry for Technologies Laboratory, University of Brescia, Brescia (Italy); Tsuji, Kouichi [Graduate School of Engineering, Osaka City University, Osaka (Japan); Fernández-Ruiz, Ramón [Servicio Interdepartamental de Investigación (SIdI), Laboratorio de TXRF, Universidad Autónoma de Madrid, Madrid (Spain); Margui, Eva [Department of Chemistry, University of Girona, Girona (Spain); Streli, Christina [TU Wien, Atominstitut,Radiation Physics, Vienna (Austria); Pepponi, Giancarlo [Fondazione Bruno Kessler, Povo, Trento (Italy); Stosnach, Hagen [Bruker Nano GmbH, Berlin (Germany); Yamada, Takashi [Rigaku Corporation, Takatsuki, Osaka (Japan); Vandenabeele, Peter [Department of Archaeology, Ghent University, Ghent (Belgium); Maina, David M.; Gatari, Michael [Institute of Nuclear Science and Technology, University of Nairobi, Nairobi (Kenya); Shepherd, Keith D.; Towett, Erick K. [World Agroforestry Centre (ICRAF), Nairobi (Kenya); Bennun, Leonardo [Laboratorio de Física Aplicada, Departamento de Física, Universidad de Concepción (Chile); Custo, Graciela; Vasquez, Cristina [Gerencia Química, Laboratorio B025, Centro Atómico Constituyentes, San Martín (Argentina); Depero, Laura E., E-mail: laura.depero@unibs.it [Chemistry for Technologies Laboratory, University of Brescia, Brescia (Italy)

    2014-11-01

    Total Reflection X-Ray Fluorescence (TXRF) is a mature technique to evaluate quantitatively the elemental composition of liquid samples deposited on clean and well polished reflectors. In this paper the results of the first worldwide TXRF round-robin test of water samples, involving 18 laboratories in 10 countries are presented and discussed. The test was performed within the framework of the VAMAS project, interlaboratory comparison of TXRF spectroscopy for environmental analysis, whose aim is to develop guidelines and a standard methodology for biological and environmental analysis by means of the TXRF analytical technique. - Highlights: • The discussion of the first worldwide TXRF round-robin test of water samples (18 laboratories of 10 countries) is reported. • Drinking, waste, and desalinated water samples were tested. • Data dispersion sources were identified: sample concentration, preparation, fitting procedure, and quantification. • The protocol for TXRF analysis of drinking water is proposed.

  14. Recent trends in total reflection X-ray fluorescence spectrometry for biological applications

    International Nuclear Information System (INIS)

    This review is focused on the application of total reflection X-ray fluorescence (TXRF) spectrometry in the field of biological research. In the last decade, most papers were published by authors who applied laboratory-scale TXRF equipments. The application of synchrotron radiation as excitation source (SR-TXRF) shows a slowly increasing tendency. In the cited papers the micro-, trace and multielement capability of these TXRF techniques was demonstrated in the clinical and medical laboratory practice, as well as in various plant physiological studies. For speciation of elements in biological matrices, the TXRF was used as element specific detector following an off-line separation step (e.g., thin layer chromatography, high performance liquid chromatography), however, these off-line methods are not competitive with the on-line coupled HPLC-inductively coupled plasma mass spectrometry

  15. Calibration method for measurement of linear nanometric distances by scattered total internal reflection

    International Nuclear Information System (INIS)

    Scattered total internal reflection of visible light is used to measure linear nanometric distance to as small as 10 nm. Specifically, we measure the height of magnetic transducer heads above a rotating glass disk. A breakthrough in the approach to calibration, based on combining the second derivative of the transmittance of the scattered light and parameter fitting, substantially improves the quality of the measurement relative to previous demonstrations of this method. The results agree to 1 nm with an industry-standard three-color interferometer to and including the lowest values measured. The technique in principle remains robust to as low as the zero height. Furthermore the calibration point can be as low as 10 nm, which is especially attractive in practice

  16. Characterization of nuclear materials by total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Nuclear energy is one of the available energy options for long term energy security of world. In order to produce electricity using this mode of energy generation in an efficient and safe manner, it is necessary that the materials used for such energy generation comply with the specifications assigned. The major and trace composition of these materials is an important specification for their quality control. Different analytical techniques are used for such quality control. Total reflection X-ray fluorescence (TXRF) is a comparatively new technique having several features well suited for trace and major element determinations in nuclear materials. However, this technique has not been used so far extensively for characterization of nuclear materials. The present paper gives a brief introduction of TXRF, its suitability for nuclear material characterization and some details of the TXRF studies made in our laboratory for the characterization of nuclear materials. (author)

  17. Nanoscale characterization of vesicle adhesion by normalized total internal reflection fluorescence microscopy.

    Science.gov (United States)

    Cardoso Dos Santos, Marcelina; Vézy, Cyrille; Jaffiol, Rodolphe

    2016-06-01

    We recently proposed a straightforward fluorescence microscopy technique to study adhesion of Giant Unilamellar Vesicles. This technique is based on dual observations which combine epi-fluorescence microscopy and total internal reflection fluorescence (TIRF) microscopy: TIRF images are normalized by epi-fluorescence ones. By this way, it is possible to map the membrane/substrate separation distance with a nanometric resolution, typically ~20nm, with a maximal working range of 300-400nm. The purpose of this paper is to demonstrate that this technique is useful to quantify vesicle adhesion from ultra-weak to strong membrane-surface interactions. Thus, we have examined unspecific and specific adhesion conditions. Concerning unspecific adhesion, we have controlled the strength of electrostatic forces between negatively charged vesicles and various functionalized surfaces which exhibit a positive or a negative effective charge. Specific adhesion was highlighted with lock-and-key forces mediated by the well defined biotin/streptavidin recognition. PMID:26972045

  18. Observation of high heat flux boiling structures in a horizontal pool by a total reflection technique

    International Nuclear Information System (INIS)

    The experiments were carried out for a horizontal pool boiling of saturated water using a transparent ITO heating surface. Details of boiling structure near the heated surface have been clearly observed by applying the total reflection and diagonal view techniques in a synchronized manner. Mechanisms for the bubble coalescence and dry area expansion processes were clearly identified. The base of the large massive bubble was mostly dry with some trapped liquid. The appearance of this large dry area at high heat flux close to CHF was basically resulted from the multiple steps of bubble coalescences which occur while the bubbles are growing, attached to the boiling surface not before they depart from the boiling surface. The thin liquid layer with distributed vapor stems was not observed under the large massive bubble. (author)

  19. Total-Internal-Reflection Platforms for Chemical and Biological Sensing Applications

    Science.gov (United States)

    Sapsford, Kim E.

    Sensing platforms based on the principle of total internal reflection (TIR) represent a fairly mature yet still expanding and exciting field of research. Sensor development has mainly been driven by the need for rapid, stand-alone, automated devices for application in the fields of clinical diagnosis and screening, food and water safety, environmental monitoring, and chemical and biological warfare agent detection. The technologies highlighted in this chapter are continually evolving, taking advantage of emerging advances in microfabrication, lab-on-a-chip, excitation, and detection techniques. This chapter describes many of the underlying principles of TIR-based sensing platforms and additionally focusses on planar TIR fluorescence (TIRF)-based chemical and biological sensors.

  20. Metals determination in coffee sample by total reflection X-ray fluorescence analysis (TXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Vives, Ana Elisa Sirito de [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo]. E-mail: aesvives@unimep.br; Moreira, Silvana [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Civil, Arquitetura e Urbanismo]. E-mail: Silvana@fec.unicamp.br; Brienza, Sandra Maria Boscolo [ Universidade Metodista de Piracicaba (UNIMEP), Piracicaba, SP (Brazil). Faculdade de Ciencias Matematicas, da Natureza e de Tecnologia da Informacao]. E-mail: sbrienza@unimep.br; Zucchi, Orgheda Luiza Araujo Domingues [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Ciencias Farmaceuticas]. E-mail: olzucchi@fcfrp.usp.br; Nascimento Filho, Virgilio Franco do [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil)]. E-mail: virgilio@cena.usp.br

    2005-07-01

    The objective of this study was to evaluate the inorganic concentration in five brands of coffee, three of them nationally marketed and the others of an exportation kind. The samples were prepared by infusion with deionized water. To carry out the calibration, standard solutions were prepared with different concentrations of Al, Si, K, Ca, Ti, Cr, Fe, Ni, Zn and Se. The measurements were carried out using a white beam of synchrotron radiation for excitation and a Si (Li) semiconductor detector for detection. By employing Synchrotron Radiation Total Reflection X-Ray Fluorescence Analysis (SR-TXRF) it was possible to evaluate the concentrations of P, S, Cl, K, Ca, Mn, Fe, Cu, Zn, Rb and Ba. The detection limits for 300 s counting time were in the range of 0.03 (Ca) to 30 ng.g{sup -1} (Rb), respectively. (author)

  1. Trace elements determination in red and white wines using total-reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Several wines produced in different regions from south of Brazil and available in markets in Rio de Janeiro were analyzed for their contents of elements such as: P, S, Cl, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Rb and Sr. Multi-element analysis was possible with simple sample preparation and subsequent analysis by total-reflection X-ray fluorescence using synchrotron radiation. The measurement was carried at the X-ray fluorescence beamline in the Synchrotron Light Source Laboratory in Campinas, Brazil. The levels of the various elements obtained were lower in the Brazilian wines than the values generally found in the literature. The present study indicates the capability of multi-element analysis for determining the contents of various elements present in wines coming from Brazil vineyards by using a simple, sensitive and precise method

  2. Ambiental applications of Total Reflection X-Ray Fluorescence in Mexico

    International Nuclear Information System (INIS)

    Full text: The National Institute of Nuclear Investigations, through the Management of Environmental Sciences has recently acquired a Total Reflection X Ray Fluorescence equipment, Ital Structures I T-2000. This is the first reflection equipment that operates in Mexico, and it allows to increase the analytic capacity in the environmental surface area of the country. This completely automated equipment is used in the environmental samples analysis, which means natural and wastewaters, silts and soils, blood, urine, fish, plankton, vegetables, filters with particulated matter, among other, using as quantification method the one called internal standard. The limits of detection vary from 4 up to 100 μg/L depending of the element and the used x-rays tube. This equipment allows to give support to different projects related with the contamination and the environmental protection in Mexico, just as the study of the distribution heavy metals in water and silt from different bodies of water, the metal accumulation in plankton, aquatic flowers, fish and birds, the study of particulate matter in Mexico City atmosphere, and in the identification of heavy metals in ground waters polluted with leached derived from mining industry

  3. The Mixture of Salvianolic Acids from Salvia miltiorrhiza and Total Flavonoids from Anemarrhena asphodeloides Attenuate Sulfur Mustard-Induced Injury

    Directory of Open Access Journals (Sweden)

    Jianzhong Li

    2015-10-01

    Full Text Available Sulfur mustard (SM is a vesicating chemical warfare agent used in numerous military conflicts and remains a potential chemical threat to the present day. Exposure to SM causes the depletion of cellular antioxidant thiols, mainly glutathione (GSH, which may lead to a series of SM-associated toxic responses. MSTF is the mixture of salvianolic acids (SA of Salvia miltiorrhiza and total flavonoids (TFA of Anemarrhena asphodeloides. SA is the main water-soluble phenolic compound in Salvia miltiorrhiza. TFA mainly includes mangiferin, isomangiferin and neomangiferin. SA and TFA possess diverse activities, including antioxidant and anti-inflammation activities. In this study, we mainly investigated the therapeutic effects of MSTF on SM toxicity in Sprague Dawley rats. Treatment with MSTF 1 h after subcutaneous injection with 3.5 mg/kg (equivalent to 0.7 LD50 SM significantly increased the survival levels of rats and attenuated the SM-induced morphological changes in the testis, small intestine and liver tissues. Treatment with MSTF at doses of 60 and 120 mg/kg caused a significant (p < 0.05 reversal in SM-induced GSH depletion. Gene expression profiles revealed that treatment with MSTF had a dramatic effect on gene expression changes caused by SM. Treatment with MSTF prevented SM-induced differential expression of 93.8% (973 genes of 1037 genes. Pathway enrichment analysis indicated that these genes were mainly involved in a total of 36 pathways, such as the MAPK signaling pathway, pathways in cancer, antigen processing and presentation. These data suggest that MSTF attenuates SM-induced injury by increasing GSH and targeting multiple pathways, including the MAPK signaling pathway, as well as antigen processing and presentation. These results suggest that MSTF has the potential to be used as a potential therapeutic agent against SM injuries.

  4. New attenuation correction for the HRRT using transmission scatter correction and total variation regularization

    DEFF Research Database (Denmark)

    Sibomana, Merence; Keller, Sune Høgild; Svarer, Claus; Olesen, Oline Vinter; Andersen, Flemming; Holm, Søren; Højgaard, Liselotte

    2009-01-01

    In the standard software for the Siemens HRRT PET scanner the most commonly used segmentation in the μ-map reconstruction for human brain scans is MAP-TR. Problems with bias in the lower cerebellum and pons in HRRT brain images have been reported. The main source of the problem is poor bone / soft......, it introduces the use of scatter correction, and secondly, it uses a simple threshold in combination with nonlinear total variation μ-map filtering. To validate the new transmission μ-map reconstruction with scatter correction and TXTV segmentation, we compared the average activity in 50 RoIs average...... on emission images reconstructed with the new TXTV and old MAP-TR μ-maps to images reconstructed with co-registered CT-based μ-maps on four 18F FDG scans. The CT μ-maps is considered a gold standard. The comparison show a significant decrease in the bias in cerebellum and pons, and a better agreement...

  5. Analysis of total oil and fatty acids composition by near infrared reflectance spectroscopy in edible nuts

    Science.gov (United States)

    Kandala, Chari V.; Sundaram, Jaya

    2014-10-01

    Near Infrared (NIR) Reflectance spectroscopy has established itself as an important tool in quantifying water and oil present in various food materials. It is rapid and nondestructive, easier to use, and does not require processing the samples with corrosive chemicals that would render them non-edible. Earlier, the samples had to be ground into powder form before making any measurements. With the development of new soft ware packages, NIR techniques could now be used in the analysis of intact grain and nuts. While most of the commercial instruments presently available work well with small grain size materials such as wheat and corn, the method present here is suitable for large kernel size products such as shelled or in-shell peanuts. Absorbance spectra were collected from 400 nm to 2500 nm using a NIR instrument. Average values of total oil contents (TOC) of peanut samples were determined by standard extraction methods, and fatty acids were determined using gas chromatography. Partial least square (PLS) analysis was performed on the calibration set of absorption spectra, and models were developed for prediction of total oil and fatty acids. The best model was selected based on the coefficient of determination (R2), Standard error of prediction (SEP) and residual percent deviation (RPD) values. Peanut samples analyzed showed RPD values greater than 5.0 for both absorbance and reflectance models and thus could be used for quality control and analysis. Ability to rapidly and nondestructively measure the TOC, and analyze the fatty acid composition, will be immensely useful in peanut varietal improvement as well as in the grading process of grain and nuts.

  6. Total reflection X-ray fluorescence and archaeometry: Application in the Argentinean cultural heritage

    International Nuclear Information System (INIS)

    Archaeometry is an interdisciplinary research area involved in the development and use of scientific methods in order to answer questions concerned with the human history. In this way the knowledge of archaeological objects through advanced chemical and physical analyses permits a better preservation and conservation of the cultural heritage and also reveals materials and technologies used in the past. In this sense, analytical techniques play an important role in order to provide chemical information about cultural objects. Considering the non destructive characteristic of this study, analytical techniques must be adequate in order to prevent any alteration or damage and in addition to allow the conservation of their integrity. Taking into account the irreplaceable character of the archaeological and artistic materials considered in this study, analytical techniques must be adequate in order to prevent any alteration or damage and in addition to allow the conservation of their integrity. Total Reflection X-ray Fluorescence Spectrometry as a geometric variant of conventional X-ray fluorescence is a proved microanalytical technique considering the small amount of sample required for the analysis. A few micrograms are enough in order to reveal valuable information about elemental composition and in this context it is highly recommended for artwork studies. In this paper a case study is presented in which Total Reflection X-Ray Fluorescence Spectrometry has been successfully employed in the archaeometry field. Examples from Argentinean cultural heritage sites related with the determination of pigments in paintings on canvas and in rock sites as well as in underwater archaeology research are shown

  7. Three approaches for direct analysis of biological samples by Total reflection X-Ray Fluorescence analysis

    International Nuclear Information System (INIS)

    One of the main advantages of the Total reflection X-Ray Fluorescence technique is feasibility of the direct analysis of the sample. taking in account this fact, three methods for the direct analysis of biological samples were evaluated For the evaluation of the method of Compton peak standardization serum, brain tissue, urine and amniotic fluid matrices were analyzed using compton Peak and the elements Co, and V as internal standard. In the case the sample itself is used as calibration standard. The method is reliable for the analysis of serum and brain tissue samples. The analytical quality of the results was similar to that obtained by the conventional method. The results were in good agreements with those obtained by the atomic absorption technique. The second method was applied to the certified Bovine Liver Standard sample 1577a. Experimental conditions for the microwave acid digestion of the solid sample directly on the quartz reflector were found, The percent of recovery of the elements S, Ci, K, Ca, Mn, Fe, Cu, Zn, Se, Br, and Rb carried between 85% and 115% and The precision was below the 10% of relative standards deviations for ten independent replicates. In the third method the concept of chemical modifications is adapted to the Total reflection X-Ray Fluorescence technique. In these experiments the main objective was the elimination of Chlorine from the matrix following the in situ addition of the reactive ammonium nitrate and heating. The method was applied to high saline content samples, i.e. amniotic fluid samples, Special care was given to the volatile elements and to the quality of the thin layer. an enhancement of the sensitivity was found for those elements with signals near the chlorine k-Alfa signal after the modifications procedure

  8. Total reflection X-ray fluorescence and archaeometry: Application in the Argentinean cultural heritage

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez, Cristina [Comision Nacional de Energia Atomica, Av. Gral Paz 1499 (B1650KNA) San Martin, Buenos Aires (Argentina); Laboratorio de Quimica de Sistemas Heterogeneos, Facultad de Ingenieria, Universidad de Buenos Aires, P. Colon 850 (C1063ACU), Buenos Aires (Argentina)], E-mail: Cristina.Vazquez@cnea.gov.ar; Albornoz, Ana [Agencia Rio Negro Cultura, Museo de la Patagonia F.P.Moreno, Centro Civico s/n Bariloche, Rio Negro (Argentina); Hajduk, Adam [CONICET, Museo de la Patagonia F.P.Moreno, Centro Civico s/n Bariloche, Rio Negro (Argentina); Elkin, Dolores [CONICET Instituto Nacional de Antropologia y Pensamiento Latinoamericano, 3 de febrero 1378 (C1426AEL) Buenos Aires (Argentina); Custo, Graciela; Obrustky, Alba [Comision Nacional de Energia Atomica, Av. Gral Paz 1499 (B1650KNA) San Martin, Buenos Aires (Argentina)

    2008-12-15

    Archaeometry is an interdisciplinary research area involved in the development and use of scientific methods in order to answer questions concerned with the human history. In this way the knowledge of archaeological objects through advanced chemical and physical analyses permits a better preservation and conservation of the cultural heritage and also reveals materials and technologies used in the past. In this sense, analytical techniques play an important role in order to provide chemical information about cultural objects. Considering the non destructive characteristic of this study, analytical techniques must be adequate in order to prevent any alteration or damage and in addition to allow the conservation of their integrity. Taking into account the irreplaceable character of the archaeological and artistic materials considered in this study, analytical techniques must be adequate in order to prevent any alteration or damage and in addition to allow the conservation of their integrity. Total Reflection X-ray Fluorescence Spectrometry as a geometric variant of conventional X-ray fluorescence is a proved microanalytical technique considering the small amount of sample required for the analysis. A few micrograms are enough in order to reveal valuable information about elemental composition and in this context it is highly recommended for artwork studies. In this paper a case study is presented in which Total Reflection X-Ray Fluorescence Spectrometry has been successfully employed in the archaeometry field. Examples from Argentinean cultural heritage sites related with the determination of pigments in paintings on canvas and in rock sites as well as in underwater archaeology research are shown.

  9. Total reflection x-ray fluorescence: Determination of an optimum geometry

    International Nuclear Information System (INIS)

    Total reflection X-Ray Fluorescence (TXRF) is a widely used technique in which the normal trace element detection capability of hard x-ray fluorescence (XRF) is enhanced by use of an x-ray reflective substrate. TXRF is more sensitive than normal photon induced XRF due to the reduction of the substrate scattering and fluorescence signals. This reduction comes about because in total external reflection, the photon field only penetrates about 20 angstrom into the surface, instead of typically 50 μm for a silicon substrate at normal incidence for 10 KeV photons. The technique is used in many fields of trace element analysis, and is widely used in the determination of metal impurity concentrations on and in the surface of silicon wafers. The Semiconductor Industry Association roadmap (SIA) indicates a need for wafer contamination detection at the 107atoms/cm2 level in the next few years. Current commercial systems using rotating anode x-ray sources presently routinely operate with a sensitivity level of around 1010 atoms/cm2 and this has led to interest in the use of synchrotron radiation to extend the sensitivity by three orders of magnitude. The pioneering work of Pianetta and co-workers at SSRL has clearly shown that this should be possible, using a fully optimized source and detector. The purpose of this work is to determine whether ALS would be a suitable source for this type of highly sensitive wafer TXRF. At first look it appears improbable as the SSRL work used a high flux multipole wiggler source, and it is clear that the detected fluorescence for relevant concentrations is small. In addition, SSRL operates at 3.0 GeV rather than 1.9 GeV, and is therefore more naturally suited to hard x-ray experiments. The aim of this work was therefore to establish a theoretical model for the scattering and fluorescence processes, so that one could predict the differences between alternative geometries and select an optimum configuration

  10. Collection of airborne particulate matter for a subsequent analysis by total reflection X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Klockenkaemper, R.; Bayer, H.; Bohlen, A. von; Schmeling, M.; Klockow, D. [Institut fuer Spektrochemie und Angewandte Spektroskopie, Dortmund (Germany)

    1995-06-01

    The collection of airborne particulate matter by filtration and impaction was adapted to total reflection X-ray fluorescence analysis (TXRF). Cellulose nitrate filters were used for collecting in a Berner impactor. Single filter spots were punched out, placed on quartz-glass carriers, dissolved by tetrahydrofuran and re-precipitated prior to element determinations by TXRF. In a Battelle-type impactor, airborne dust was collected on Plexiglass carriers coated with medical Vaseline. The loaded carriers were directly analyzed by TXRF. In both cases, quantification was simply performed by the addition of an internal standard after sampling. Impactors were made of a suitable material in order to investigate high blank values, collection losses and memory effects. It could be shown that stainless steel, even coated with TiN, is less suitable and should be avoided as an impactor material. Although aluminum is partly recommendable, titanium and the polymer Makrolon are quite appropriate. By using an impactor made of these materials, a reliable multielement determination in airborne dust is made possible with low detection limits as low as 1 ng/m{sup 3} and a satisfactory repeatability of a few %. Short sampling times of only 1 h or less can be realized. The total procedure is simple and time-saving, and can be recommended for routine investigations of airborne particulate matter. (author).

  11. Determination of carbon in natural freshwater biofilms with total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    There is a growing interest in determination of low Z elements, i.e., carbon to phosphorus, in biological samples. Total reflection X-ray fluorescence spectrometry (TXRF) has been already established as suitable trace element analytical method with low sample demand and quite good quantification limits. Recently, the determinable element range was extended towards Z = 6 (carbon). Biofilms can be used for biomonioring purposes in the aquatic environment. Besides the trace metals, especially the determination of the carbon content is important for the better understanding of the early stage of biofilm formation. For this, an ATI low Z spectrometer equipped with Cr-anode X-ray tube, multilayer monochromator, vacuum chamber, and a Si(Li) detector with ultra thin window was used. Biofilms were grown on two different artificial supports (granite and plexiglass), freeze dried, suspended in high purity water and analyzed. As an internal standard the natural titanium content of the biofilms was used. The accuracy of the method was checked by total carbon measurement using a combusting carbon analyzer.

  12. Considerations on the ideal sample shape for Total Reflection X-ray Fluorescence Analysis

    International Nuclear Information System (INIS)

    Total Reflection X-ray Fluorescence analysis (TXRF) is widely used in semiconductor industry for the analysis of silicon wafer surfaces. Typically an external standard is used for the calibration of the spectrometer. This is sensitive to errors in quantification. For small sample amounts the thin film approximation is valid, absorption effects of the exciting and the detected radiation are neglected and the relation between sample amount and fluorescence intensity is linear. For higher total sample amounts deviations from linearity have been observed (saturation effect). These deviations are one of the difficulties for external standard quantification. A theoretical determination of the ideal TXRF sample shape is content of the presented work with the aim to improve the calibration process and therefore the quantification. The fluorescence intensity emitted by different theoretical sample shapes was calculated, whereby several parameters have been varied (excitation energy, density, diameter/height ratio of the sample). It was investigated which sample shape leads to the highest fluorescence intensity and exhibits the lowest saturation effect. The comparison of the different sample shapes showed that the ring shape matches the ideal TXRF sample shape best. - Highlights: ► In this work the ideal TXRF sample shape is theoretically determined. ► Different theoretical sample shapes were investigated. ► The ring shape matches the ideal TXRF sample shape best. ► It leads to the highest fluorescence intensity and the lowest saturation effect.

  13. Optical absorption under total internal reflection in the characterization of soot in diesel engine oils

    International Nuclear Information System (INIS)

    Optical absorption of infrared radiation under total internal reflection in a novel sensor has been utilized to investigate the soot contamination of diesel engine oil by response surface methodology in factorial experiments. Sensor response showed highly significant dependence on oil soot concentration and temperature, in which the effect of the soot was greatest. The soot contamination of the optical rod in engine oil was found to be a surface phenomenon which showed little or no dependence on bulk oil shearing displacement below 500 rpm. The quadratic effect of sensor response to soot concentration was very high due to the agglomeration of soot particles, derived from the high surface energy of carbon soot. Test results of this optical absorption technique were in conformance with those other oil analysis techniques such as UV spectrophotometry, total acid number, viscosimetry, optical microscopy and EPMA. The technique proved to be more reliable than RDE emission spectrometry which showed ambiguous results due to colloidal suspension of soot particles in oil. Optical absorption proved to be an effective criterion in characterizing the soot contamination of diesel engine oil

  14. Novel Propagation Properties of Total Internal Reflection Photonic Crystal Fibres with Rhombic Air Holes

    Institute of Scientific and Technical Information of China (English)

    YAN Hai-Feng; YU Zhong-Yuan; LIU Yu-Min; TIAN Hong-Da; HAN Li-Hong

    2011-01-01

    We investigate the propagation properties of a multi-layer photonic crystal fiber with novel rhombic air holes using the finite element method,and calculate the dependence of the propagation properties on the wavelength in the fiber with different geometrical structural parameters,including the internal angle and the external arrangement of the rhombic air holes.Optimizing these parameters,we design a photonic crystal which exhibits both a small dispersion value and low loss near the wavelength of 1.55 μm.Photonic crystal fibers are known as microstructured optical fibers or multi-hole optical fibers,and their cross sections have periodic structures with hollows in the centers due to one or more missing air holes as shown in Fig.1.The light wave can propagate along this hollow structure,which can be considered as the core of the fiber.According to the light-guiding mechanism,there are two types of photonic crystal fibers:total internal reflection photonic crystal fibers and photonic bandgap photonic crystal fibers.[1] The propagation properties of total internal reflection photonic crystal fibers are determined by the arrangements of holes in the transverse field.[1,2] With the flexibility to control the arrangement,size and shape of the air holes,various photonic crystal fibers with different optical properties can be designed as desired.Recently the microstructural design of photonic crystal fibers has drawn extensive attention over the world.[3] As a novel kind of optical fiber,photonic crystal fibers have been widely used for optoelectronic devices.%We investigate the propagation properties of a multi-layer photonic crystal fiber with novel rhombic air holes using the finite element method, and calculate the dependence of the propagation properties on the wavelength in the fiber with different geometrical structural parameters, including the internal angle and the external arrangement of the rhombic air holes. Optimizing these parameters, we design a photonic

  15. Production of the ideal sample shape for Total Reflection X-ray Fluorescence analysis

    International Nuclear Information System (INIS)

    Total Reflection X-ray Fluorescence analysis (TXRF) is a well-established analytical method in the semiconductor industry for the analysis of silicon wafer surfaces. For the calibration of the spectrometer typically an external standard is used which is sensitive to quantification errors. In general TXRF is known to allow for linear calibration. For small sample amounts (pg to ng region) the thin film approximation is valid neglecting absorption effects of the exciting and the detected radiation. For higher total amounts of sample the relation between fluorescence intensity and sample amount diverges from linearity (saturation effect). These deviations lead to difficulties in quantification with external standard. Content of the presented work is the production of the ideal TXRF sample shape, which was theoretically determined to be ring shaped. A possibility for the production of samples with ring shape is the use of a nanodispensing system combined with a positioning device. Therewith it is possible to produce ring shaped samples in a controlled way with the ring consisting of individual nanodroplets, so that the wanted diameter of the ring can be chosen. A comparison of the fluorescence intensities emitted by contracted and ring shaped samples shows that the ring shape is not only theoretically the best TXRF shape but also experimentally. It could be proven that for contracted samples the saturation effect occurs at a lower sample mass than for samples with ring shape. - Highlights: ► The ring shape was found to be the theoretically ideal TXRF sample in a former study. ► A nanodispensing system enables the production of ring shaped samples. ► Contracted and ring shaped samples were compared. ► The ring shape was also experimentally proven to be the best TXRF shape.

  16. High nitrate to phosphorus regime attenuates negative effects of rising pCO2 on total population carbon accumulation

    Science.gov (United States)

    Matthiessen, B.; Eggers, S. L.; Krug, S. A.

    2012-03-01

    The ongoing rise in atmospheric pCO2 and consequent increase in ocean acidification have direct effects on marine calcifying phytoplankton, which potentially alters carbon export. To date it remains unclear, firstly, how nutrient regime, in particular by coccolithophores preferred phosphate limitation, interacts with pCO2 on particulate carbon accumulation; secondly, how direct physiological responses on the cellular level translate into total population response. In this study, cultures of Emiliania huxleyi were full-factorially exposed to two different N:P regimes and three different pCO2 levels. Cellular biovolume and PIC and POC content significantly declined in response to pCO2 in both nutrient regimes. Cellular PON content significantly increased in the Redfield treatment and decreased in the high N:P regime. Cell abundance significantly declined in the Redfield and remained constant in the high N:P regime. We hypothesise that in the high N:P regime severe phosphorous limitation could be compensated either by reduced inorganic phosphorous demand and/or by enzymatic uptake of organic phosphorous. In the Redfield regime we suggest that enzymatic phosphorous uptake to supplement enhanced phosphorous demand with pCO2 was not possible and thus cell abundance declined. These hypothesised different physiological responses of E. huxleyi among the nutrient regimes significantly altered population carrying capacities along the pCO2 gradient. This ultimately led to the attenuated total population response in POC and PIC content and biovolume to increased pCO2 in the high N:P regime. Our results point to the fact that the physiological (i.e. cellular) PIC and POC response to ocean acidification cannot be linearly extrapolated to total population response and thus carbon export. It is therefore necessary to consider both effects of nutrient limitation on cell physiology and their consequences for population size when predicting the influence of coccolithophores on

  17. Characterization and classification of spirituous beverages by total reflection x-ray fluorescence

    International Nuclear Information System (INIS)

    The total reflection x-ray fluorescence (TXRF) technique was applied for the multi-elemental analysis of spirituous beverages like rum, cocuy (typical spirituous beverage in Venezuela), whiskey and wine, in order to classify the samples by product processing and geographical origin by chemometric analysis. Special attention was paid to the cocuy samples, since there is a lack of quality control of this beverage, mainly due to the home-made product processing. The use of the Compton peak information was evaluated for the determination of organic content in samples. In the specifically case of cocuy samples the Compton peak area was correlated to the ash content for detection of adulteration with sugar syrup. Cocuy samples were also analyzed using gas chromatography, for pH, acidity, ash content and refractometry, in order to develop the recognition pattern. The TXRF analysis was carried out in a Canberra spectrometer, using the K α-line of a Motube, by a direct procedure previously developed. The analysis of the data was done by using principal components analysis and a confidence test. The results show that TXRF and chemometric analysis is a useful tool for quality control of spirituous beverages, not only concerning to metal content, but also in the evaluation of sugar and non volatile organic content. (author)

  18. Characterization of nuclear materials by total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Nuclear energy is one of the available energy options for long term energy security of world. In order to produce electricity using this mode of energy generation in an efficient and safe manner, it is necessary that the materials used for such energy generation comply with the specifications assigned. The major and trace composition of these materials is an important specification for their quality control. Different analytical techniques are used for such quality control. Total Reflection X-ray Fluorescence is a comparatively new technique having several features well suited for trace and major element determinations in nuclear materials. However, this technique has not been used so far extensively for characterization of nuclear materials. Some studies for characterization of nuclear materials using TXRF has been carried out in Fuel Chemistry Division, BARC. A brief introduction of TXRF, its suitability for nuclear material characterization and some details of the TXRF studies made in Fuel Chemistry Division for the characterization of nuclear materials are described in the present paper. (author)

  19. Investigation of polyelectrolytes by total reflection x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Water soluble polyelectrolyte samples containing mono-, bi- and trivalent metal ions were investigated without any pretreatment. Acid digestion of linear polymers may lead to a product insoluble in water so the digestion has to be avoided. The aim of this paper was the determination of analytical characteristics and limitations of the total reflection x-ray fluorescence (TXRF) analysis for poly (vinylalcohol-vinylsulphate) salts and poly (acrylic acid, acrylamide) copolymers containing the following cations: K+, Cs+, Ba2+, Cu2+ and La3+. On the basis of our results efficiency of ion-exchange during preparation of polyelectrolytes and stoichiometry of the end-product were determined. TXRF results were compared with data gained by inductively coupled plasma atomic emission spectrometry (ICP-AES) measurements except in the case of Cs+ which has poor sensitivity in ICP-AES. Good agreement was found between the results of the two techniques and calculations from titrimetric data. Concentration of Li+ and Mg2+ in polymer samples was measured by ICP-AES. In majority of cases film-like dry residues of aqueous solutions of polyelectrolytes can be characterized by homogeneous spatial distribution of metal ions within the organic matrix. This is because the migration of the ions is hindered during drying process. Determination of metals in polyelectrolyte films by TXRF is quite ideal as model for analysis of plant, animal or human tissues which is a frequent task in environmental and inorganic biomedical analytical chemistry. (author)

  20. Portable total reflection x-ray fluorescence spectrometer for ultra trace elemental determination

    International Nuclear Information System (INIS)

    It has been believed that the use of high power monochromatic incident X-rays such as monochromatic synchrotron radiation is essential for improving detection limits in the total reflection X-ray fluorescence (TXRF) analysis. On the other hand, we have reported that polychromatic excitation improves detection limits in the TXRF analysis compared with monochromatic excitation. We have developed portable TXRF spectrometers using polychromatic X-rays from a low power (several watts) X-ray tube, and a 10 pg (10-11 g) detection limit is achieved with the weak polychromatic X-rays. This low detection limit is obtained using the following methods with polychromatic excitation: (1) measuring smaller amounts of a sample, (2) optimization of a tube voltage, and tube current, (3) optimization of a glancing angle, (4) the use of an appropriate target material of an X-ray tube, and (5) the use of an X-ray waveguide. In the present paper, experimental set-up of the present portable spectrometer and the change of detection sensitivity by changing experimental conditions such as tube voltage are explained. Applications to trace elemental analysis of urine and pigments are also shown. (author)

  1. Analysis of mineral water from Brazil using total reflection X-ray fluorescence by synchrotron radiation

    International Nuclear Information System (INIS)

    The total reflection X-ray fluorescence using synchrotron radiation (SRTXRF) has become a competitive technique for the determination of trace elements in samples that the concentrations are lower than 100 ng ml-1. In this work, thirty-seven mineral waters commonly available in supermarkets of Rio de Janeiro, Brazil, were analyzed by SRTXRF. The measurements were performed at the X-Ray Fluorescence Beamline at Brazilian National Synchrotron Light Laboratory (LNLS), in Campinas, Sao Paulo, using a polychromatic beam with maximum energy of 20 keV for the excitation. Standard solutions with gallium as internal standard were prepared for calibration of the system. Mineral water samples of 10 μl were added to Perspex sample carrier, dried under infrared lamp and analyzed for 200 s measuring time. It was possible to determine the concentrations of the following elements: Si, S, K, Ca, Ti, Cr, Mn, Ni, Cu, Zn, Ge, Rb, Sr, Ba and Pb. The elemental concentration values were compared with the limits established by the Brazilian legislation

  2. Visualizing substructure of Ca2+ waves by total internal reflection fluorescence microscopy

    Science.gov (United States)

    Bai, Yongqiang; Tang, Aihui; Wang, Shiqiang; Zhu, Xing

    2005-02-01

    Total internal reflection fluorescence microscope is a new optical microscopic system based on near-field optical theory. Its character of illumination by evanescent wave, together with the great signal-to-noise ratio and temporal resolution achieved by high quality CCD, allows us to analyze the spatiotemporal details of local Ca2+ dynamics within the nanoscale microdomain surrounding different Ca2+ channels. We have recently constructed a versatile objective TIRFM equipped with a high numerical aperture (NA=1.45) objective. Using fluo-4 as the Ca2+ indicator, we visualized the near-membrane profiles of Ca2+ waves and elementary Ca2+ sparks generated by Ca2+ release channels in rat ventricular myocytes. Different from those detected using conventional and confocal microscopy, Ca2+ waves observed with TIRFM exhibited fine inhomogenous substructures composed of fluctuating Ca2+ sparks. The anfractuous routes of spark recruitment suggested that the propagation of Ca2+ waves is much more complicated than previously imagined. We believe that TIRFM will provide a unique tool for dissecting the microscopic mechanisms of intracellular Ca2+ signaling.

  3. Near-wall nanovelocimetry based on Total Internal Reflection Fluorescence with continuous tracking

    CERN Document Server

    Li, Zhenzhen; Lee, Choongyeop; Monti, Fabrice; Yonger, Marc; Chollet, Benjamin; Bresson, Bruno; Tran, Yvette; Tabeling, Patrick

    2014-01-01

    The goal of this work is to make progress in the domain of near-wall velocimetry. The technique we use is based on the tracking of nanoparticles in an evanescent field, close to a wall, a technique called TIRF (Total Internal Reflection Fluorescence)-based velocimetry. At variance with the methods developed in the literature, we permanently keep track of the light emitted by each particle during the time the measurements of their positions ('altitudes') and speeds are performed. By performing the Langevin simulation, we quantified effect of biases such as Brownian motion, heterogeneities induced by the walls, statistical biases, photo bleaching, polydispersivity and limited depth of field. Using this method, we obtained slip length on hydrophilic surfaces of 1$ \\pm $5 nm for sucrose solution, and 9$ \\pm $10 nm for water; On hydrophobic surface, 32$ \\pm $5 nm for sucrose solution, and 55$ \\pm $9 nm for water. The errors (based on 95% confidence intervals) are significantly smaller than the state-of-the-art, bu...

  4. Preparation of Reactions for Imaging with Total Internal Reflection Fluorescence Microscopy.

    Science.gov (United States)

    Kudalkar, Emily M; Davis, Trisha N; Asbury, Charles L

    2016-01-01

    Here we present our standard protocol for studying the binding of kinetochore proteins to microtubules as a paradigm for designing single-molecule total internal reflection fluorescence (TIRF) microscopy experiments. Several aspects of this protocol require empirical optimization, including the method for anchoring the polymer or substrate to the coverslip, the type and amount of blocking protein to prevent nonspecific protein adsorption to the glass, the appropriate protein concentration, the laser power, and the duration of imaging. Our method uses bovine serum albumin and κ-casein as blocking agents to coat any imperfections in the coverslip silanization and thereby prevent protein adsorption to the coverslip. Protein concentration and duration of imaging must be optimized for each experiment and protein of interest. Ideally, a range is determined that allows for resolution of single complexes binding to microtubules to ensure proper measurement of kinetic off rates and diffusion along microtubules. Excessively high concentrations may lead to overlapping binding of proteins on microtubules, making it impossible to resolve single binding events. The duration of imaging must be long enough to capture very low off rates (long residence time on microtubules) and we typically image at 10 frames/sec for 200 sec. The laser power can be adjusted to prevent photobleaching, but must be high enough to achieve a sufficient signal/noise ratio. PMID:27140912

  5. Total reflection X-ray fluorescence as a tool for food screening

    Science.gov (United States)

    Borgese, Laura; Bilo, Fabjola; Dalipi, Rogerta; Bontempi, Elza; Depero, Laura E.

    2015-11-01

    This review provides a comprehensive overview of the applications of total reflection X-ray fluorescence (TXRF) in the field of food analysis. Elemental composition of food is of great importance, since food is the main source of essential, major and trace elements for animals and humans. Some potentially toxic elements, dangerous for human health may contaminate food, entering the food chain from the environment, processing, and storage. For this reason the elemental analysis of food is fundamental for safety assessment. Fast and sensitive analytical techniques, able to detect major and trace elements, are required as a result of the increasing demand on multi-elemental information and product screening. TXRF is suitable for elemental analysis of food, since it provides simultaneous multi-elemental identification in a wide dynamic range of concentrations. Several different matrices may be analyzed obtaining results with a good precision and accuracy. In this review, the most recent literature about the use of TXRF for the analysis of food is reported. The focus is placed on the applications within food quality monitoring of drinks, beverages, vegetables, fruits, cereals, animal derivatives and dietary supplements. Furthermore, this paper provides a critical outlook on the developments required to transfer these methods from research to the industrial and analytical laboratories contexts.

  6. Multielemental analysis in cigarettes using total reflection X-ray fluorescence with synchrotron radiation

    International Nuclear Information System (INIS)

    Full text: It is well known that trace elements have important ejects in the life processes. Some of these elements are toxic for the human even at a very low level of intake. It is known that tobacco plant easily absorbs the heavy metals from the soil, especially Cd and Ni, accumulating them in its leaves. Part of these metals are transferred from tobacco to human body where they will be accumulated and damage some organs, mainly kidneys and liver. In this way, cigarettes are responsible for the death of millions of people in the world, about one death every eight seconds. The aim of this work was to determine the elemental concentrations of ten different elements in tobacco of Brazilian cigarettes used Total Reflection X-Ray Fluorescence with Synchrotron Radiation method. The fluorescence measurements were carried out at Brazilian Synchrotron Light Laboratory, Campinas - Sao Paulo. A qualitative analysis of spectral peaks showed that the samples contained potassium, calcium, titanium, chromium, manganese, iron, copper, rubidium and strontium. Among these elements, calcium, potassium and iron presented the highest concentrations. There was a wide range in the elemental concentrations in the tobacco, due various factors, such as agricultural practices, soil characteristics, climatic conditions and plant varieties. Our results are in good concern with the results reported by the scientific literature

  7. Optical design and laser ablation of surface textures: demonstrating total internal reflection

    Science.gov (United States)

    Gommans, Hans; Booij, Silvia; Pijlman, Fetze; Krijn, Marcel; de Zwart, Siebe; Sepkhanov, Ruslan; Beaumont, Dave; van der Schaft, Hans; Sanders, Rene

    2015-09-01

    In lighting applications key drivers for optical design of surface textures are integration of optical elements, the disentanglement of optical functionality and appearance and late stage configuration. We investigated excimer laser ablation as a mastering technology for micro textured surfaces, where we targeted an increase in correspondence between surface design and ablated surface for high aspect ratio structures. To achieve this we have improved the photo mask design using a heuristic algorithm that corrects for the angular dependence of the ablation process and the loss of image resolution at ablation depths that exceed the depth of field. Using this approach we have been able to demonstrate close correspondence between designed and ablated facet structures up to 75° inclination at 75 μm depth. These facet design parameters allow for total internal reflection (TIR) as a means of beam deflection which is demonstrated in a range of mono shaped cone arrays in hexagonal tessellation. BSDF analysis was used to characterize the narrow TIR deflection beams that matched the peak positions of the design down to 28° apex. In addition, a single surface TIR-Fresnel lens design with focal distance 5 mm has been manufactured using this photo mask design algorithm and beam collimation up to 12° beam angle and 32° field angle is shown. These outcomes demonstrate that the laser ablation process intrinsically yields sufficient small dispersion in structure and fillet radii for lighting applications.

  8. Total Reflection X-ray Fluorescence Analysis (TXRF) using the high flux SAXS camera

    CERN Document Server

    Wobrauschek, P; Pepponi, G; Bergmann, A; Glatter, O

    2002-01-01

    Combining the high photon flux from a rotating anode X-ray tube with an X-ray optical component to focus and monochromatize the X-ray beam is the most promising instrumentation for best detection limits in the modern XRF laboratory. This is realized by using the design of a high flux SAXS camera in combination with a 4 kW high brilliant rotating Cu anode X-ray tube with a graded elliptically bent multilayer and including a new designed module for excitation in total reflection geometry within the beam path. The system can be evacuated thus reducing absorption and scattering of air and removing the argon peak in the spectra. Another novelty is the use of a Peltier cooled drift detector with an energy resolution of 148 eV at 5.9 keV and 5 mm sup 2 area. For Co detection limits of about 300 fg determined by a single element standard have been achieved. Testing a real sample NIST 1643d led to detection limits in the range of 300 ng/l for the medium Z.

  9. Development of a total reflection X-ray fluorescence spectrometer for ultra-trace element analysis

    Indian Academy of Sciences (India)

    M K Tiwari; B Gowrishankar; V K Raghuvanshi; R V Nandedkar; K J S Sawhney

    2002-10-01

    A simple and fairly inexpensive total reflection X-ray fluorescence (TXRF) spectrometer has been designed, constructed and realized. The spectrometer is capable of ultra-trace multielement analysis as well as performs surface characterization of thin films. The TXRF setup comprises of an X-ray generator, a slitcollimator arrangement, a monochromator/cutoff-stage, a sample reflector stage and an X-ray detection system. The glancing angle of incidence on the two reflectors is implemented using a sine-bar mechanism that enables precise angle adjustments. An energy dispersive detector and a GM counter are employed for measuring respectively the fluorescence intensities and the direct X-ray beam intensity. A Cu-target X-ray generator with its line focus window is used as an excitation source. The spectrometer is quite portable with its compact design and use of a peltier cooled solid state detector for energy dispersive detection. Alignment and characterization of the TXRF system has been performed and the minimum detection limits for various elements have been determined to be in the range of 100 pg to 5 ng even at low X-ray generator powers of 30 kV, 5 mA. The capability of the TXRF system developed for thin film characterization is also demonstrated.

  10. A new approach for archaeological ceramics analysis using total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    The purpose of this study is to investigate the use of a new quantitative analysis method in case total reflection X-ray fluorescence (TXRF) is applied to archaeological ceramics. This method is alternative to and simpler than traditional TXRF quantitative analysis or typical techniques of elemental analysis such as atomic emission and absorption spectrometry (AES and AAS) which implies the chemical digestion of the sample. A new procedure which allows to obtain an homogeneous sample has been successfully applied. This way it was possible to obtain quantitative results for the elements present in the sedimentation obtained from a suspension prepared with the ceramic sample, by resorting to addition of an internal standard. The archaeological ceramic shards have been also chemically digested and analyzed by inductively coupled plasma-atomic emission spectrometry, AES with flame atomization and electrothermal atomic absorption spectrometry. The quantitative data obtained by means of both TXRF, AAS and AES were compared and worked out by multivariate statistical techniques, such as principal components analysis and hierarchical cluster analysis in order to achieve information concerning pottery provenance

  11. Use of liposomal amplifiers in total internal reflection fluorescence fiber-optic biosensors for protein detection.

    Science.gov (United States)

    Chang, Ying-Feng; Fu, Chen; Chen, Yi-Ting; Fang-Ju Jou, Amily; Chen, Chii-Chang; Chou, Chien; Annie Ho, Ja-An

    2016-03-15

    Evanescent-wave excited fluorescence technology has been demonstrated to enhance sensitivity and reduce matrix effects, making it suitable for biosensor development. In this study, we developed a liposome-based, total internal reflection fluorescence, fiber-optic biosensor (TIRF-FOB) for protein detection, which integrates a liposomal amplifier and sandwich immunoassay format with TIRF-FOB. In addition, the antibody-tagged and fluorophore-entrapped liposomes for heterogeneous detection of target molecules were designed and synthesized. This biosensor successfully detected the target protein (model analyzed here is IgG) with a limit of detection (LOD) of 2.0 attomoles for the target protein (equivalent to 2.0 pg/mL of protein presented in 150 μL of sample solution). The features of this ultra-sensitive liposomal TIRF-FOB are (i) fluorescence is excited via evanescent waves and amplified via liposomes; (ii) the use of two polyclonal antibodies in the sandwich assay format increases the specificity and lowers the cost of our assay. Based on the exceptional detection sensitivity and cost-effectiveness, we believe that the proposed biosensor has great potential as a practical, clinical diagnostic tool in the near future. PMID:26595485

  12. Sample pretreatment strategies for total reflection X-ray fluorescence analysis: A tutorial review

    Energy Technology Data Exchange (ETDEWEB)

    De La Calle, I.; Cabaleiro, N.; Romero, V.; Lavilla, I.; Bendicho, C., E-mail: bendicho@uvigo.es

    2013-12-01

    In the last years, there has been a revival of total reflection X-ray fluorescence spectrometry (TXRF), which was firstly applied for analytical purposes in the late 80s. The aim of this work is to discuss and compare the current approaches for sample pretreatment including in situ microdigestion, slurry preparation, acid digestion, extraction, etc. prior to TXRF analysis. Advantages and drawbacks inherent to each of those procedures are considered. A comprehensive revision in the period January 2008–July 2013 about different sample preparation strategies prior to TXRF analysis apart from early pioneering reports dealing with sample pretreatment are included in the review. Non-conventional sample pretreatment approaches such as microflow online preconcentration, lab-on-a-chip, etc., are also discussed. Finally, future prospects in sample preparation prior to TXRF analysis are outlined. - Highlights: • We review sample pretreatment for TXRF in a comprehensive way. • Strategies for analysis of solid, liquid and gaseous samples are discussed. • A tutorial review is presented covering the period January 2008–July 2013. • Future prospects for sample pretreament approaches in TXRF are outlined.

  13. Metal ions diffusion through polymeric matrices: A total reflection X-ray fluorescence study

    International Nuclear Information System (INIS)

    This work proposes the use of X-ray fluorescence with total reflection geometry to explore the metal ions transport in aqueous hydrophilic polymer solutions. It is centered in the study of polymer concentration influence on ion diffusion. This subject is relevant to various and diverse applications, such as drug controlled release, microbiologic corrosion protection and enhanced oil recovery. It is anticipated that diffusion is influenced by various factors in these systems, including those specific to the diffusing species, such as charge, shape, molecular size, and those related to the structural complexity of the matrix as well as any specific interaction between the diffusing species and the matrix. The diffusion of nitrate salts of Ba and Mn (same charge, different hydrodynamic radii) through water-swollen polymeric solutions and gels in the 0.01% to 1% concentration ranges was investigated. The measurements of the metal concentration were performed by TXRF analysis using the scattered radiation by the sample as internal standard. Results are discussed according to different physical models for solute diffusion in polymeric solutions

  14. Radio-frequency Attenuation Length, Basal-Reflectivity, Depth, and Polarization Measurements from Moore's Bay in the Ross Ice-Shelf

    CERN Document Server

    Barwick, S W; Besson, D; Duffin, T; Hanson, J C; Klein, S R; Kleinfelder, S A; Reed, C; Roumi, M; Stezelberger, T; Tatar, J; Walker, J; Zou, L

    2014-01-01

    Radio-glaciological parameters from Moore's Bay, in the Ross Ice Shelf, have been measured. The thickness of the ice shelf in Moore's Bay was measured from reflection times of radio-frequency pulses propagating vertically through the shelf and reflecting from the ocean. The average depth obtained is $576\\pm8$ m. The temperature-averaged attenuation length of the ice column, $\\langle L \\rangle$, is derived from the returned power assuming 100\\% reflection. A linear fit to the data yields $\\langle L(\

  15. Thermal dissociation cavity attenuated phase shift spectroscopy for continuous measurement of total peroxy and organic nitrates in the clean atmosphere

    Science.gov (United States)

    Sadanaga, Yasuhiro; Takaji, Ryo; Ishiyama, Ayana; Nakajima, Kazuo; Matsuki, Atsushi; Bandow, Hiroshi

    2016-07-01

    A thermal dissociation cavity attenuated phase shift spectroscopy (TD-CAPS) instrument was developed for measuring total peroxy nitrates (PNs) and organic nitrates (ONs) concentrations in the clean atmosphere. This instrument is easy to operate and can be applied to continuous measurement of PNs and ONs. A continuously measurable system is convenient to perform observations, especially in remote areas. Three lines (NO2, PNs, and ONs lines) were used for thermal dissociation. The NO2 line contains a quartz tube that is not heated, while the PN and ON lines contain quartz tubes that are heated at 433 K and 633 K, respectively. The concentrations of NO2, NO2 + PNs, and NO2 + PNs + ONs can be obtained from the NO2, PN, and ON lines, respectively. The lower limit values of the detection limit (3σ) for PNs and ONs were estimated to be 21 parts per trillion by volume with an integration time of 2 min. PNs were selectively thermally decomposed in the PNs line and formed NO2 quantitatively. In the ONs line, both PNs and ONs were thermally decomposed to produce NO2 quantitatively, but partial decomposition of HNO3 at 633 K interfered with the ONs measurement. Therefore, a HNO3 scrubber is required before the ONs line. Continuous observations were conducted with the TD-CAPS instrument in a remote area, and the instrument performed well for obtaining PNs and ONs concentrations.

  16. Total reflection X-ray fluorescence spectrometers for multielement analysis: status of equipment

    Science.gov (United States)

    Ayala Jiménez, Rony E.

    2001-11-01

    Multielement analysis by total reflection X-ray fluorescence spectrometry has evolved during two decades. At present commercial equipment is available for chemical analysis of all types of biological and mineral samples. The electronic industry has also benefited from scientific and technological developments in this field due to new instrumentation to determine contamination on the surface of silicon wafers (the equipment will not be covered in this paper). The basic components of the spectrometers can be summarized as follows: (a) excitation source; (b) geometric arrangement (optics) for collimation and monochromatization of the primary radiation; (c) X-ray detector; and (d) software for operation of the instrument, data acquisition and spectral deconvolution to determine the concentrations of the elements (quantitative analysis). As an optional feature one manufacturer offers a conventional 45° geometry for direct excitation. Personal communications of the author and commercial brochures available have allowed us to list the components used in TXRF for multielement analysis. Excitation source: high-power sealed X-ray tubes, output from 1300 to 3000 W, different mixed alloy anodes Mo/W are used but molybdenum, tungsten and copper are common; single anode metal ceramic low power X-ray tubes, output up to 40 W. Excitation systems can be customized according to the requirements of the laboratory. Detector: silicon-lithium drifted semiconductor detector liquid nitrogen cooled; or silicon solid state thermoelectrically cooled detector (silicon drift detector SDD and silicon-PIN diode detector). Optics: multilayer monochromator of silicon-tungsten, nickel-carbon or double multilayer monochromator. Electronics: spectroscopy amplifier, analog to digital converter adapted to a PC compatible computer with software in a Windows environment for the whole operation of the spectrometer and for qualitative/quantitative analysis of samples are standard features in the

  17. Deconstructing the late phase of vimentin assembly by total internal reflection fluorescence microscopy (TIRFM.

    Directory of Open Access Journals (Sweden)

    Stefan Winheim

    Full Text Available Quantitative imaging of intermediate filaments (IF during the advanced phase of the assembly process is technically difficult, since the structures are several µm long and therefore they exceed the field of view of many electron (EM or atomic force microscopy (AFM techniques. Thereby quantitative studies become extremely laborious and time-consuming. To overcome these difficulties, we prepared fluorescently labeled vimentin for visualization by total internal reflection fluorescence microscopy (TIRFM. In order to investigate if the labeling influences the assembly properties of the protein, we first determined the association state of unlabeled vimentin mixed with increasing amounts of labeled vimentin under low ionic conditions by analytical ultracentrifugation. We found that bona fide tetrameric complexes were formed even when half of the vimentin was labeled. Moreover, we demonstrate by quantitative atomic force microscopy and electron microscopy that the morphology and the assembly properties of filaments were not affected when the fraction of labeled vimentin was below 10%. Using fast frame rates we observed the rapid deposition of fluorescently labeled IFs on glass supports by TIRFM in real time. By tracing their contours, we have calculated the persistence length of long immobilized vimentin IFs to 1 µm, a value that is identical to those determined for shorter unlabeled vimentin. These results indicate that the structural properties of the filaments were not affected significantly by the dye. Furthermore, in order to analyze the late elongation phase, we mixed long filaments containing either Alexa 488- or Alexa 647-labeled vimentin. The 'patchy' structure of the filaments obtained unambiguously showed the elongation of long IFs through direct end-to-end annealing of individual filaments.

  18. Total-reflection x-ray fluorescence with a brillant undulator x-ray source

    International Nuclear Information System (INIS)

    Total-reflection x-ray fluorescence (TXRF) is a highly sensitive technique for analyzing trace elements, because of the very low background from the sample support. Use of third-generation synchrotron x-ray source could further enhance the detection power. However, while such high sensitivity permits the detection of signals from trace elements of interest, it also means that one can observe weak parasitic x-rays as well. If the sample surface becomes even slightly contaminated, owing to air particulates near the beamline, x-ray fluorescence lines of iron, zinc, copper, nickel, chromium, and titanium can be observed even for a blank sample. Another critical problem is the low-energy-side tail of the scattering x-rays, which ultimately restricts the detection capability of the technique using a TXRF spectrometer based on a Si(Li) detector. The present paper describes our experiments with brilliant undulator x-ray beams at BL39XU and BL40XU, at the SPring-8, Harima, Japan. The emphasis is on the development of instruments to analyze a droplet of 0.1 μl containing trace elements of ppb level. Although the beamline is not a clean room, we have employed equipment for preparing a clean sample and also for avoiding contamination during transferring the sample into the spectrometer. We will report on the successful detection of the peak from 0.8 ppb selenium in a droplet (absolute amount 80 fg). We will also present the results of recent experiments obtained from a Johansson spectrometer rather than a Si(Li) detector. (author)

  19. Determination of total As in onion plants growing in contaminated substrates by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    The onion (Allium cepa L.) is one of the most important cultivars in the world and its production level occupies the second place in Venezuela. It becomes important to develop analytical procedures for arsenic determination and to study the effect of this element on the cultures, as well the absorption, transport and translocation processes. A TXRF method for As determination in onions was developed. Two treatments were applied to the onion plants, As contaminated and control. The contaminant was added to the plants to an amount of 100 μg, in a single time 3 weeks after the transplant of plantlets. The green leaves bulbs, and roots together with the stems were separated 45 days after transplant and analyzed by TXRF and HG-AAS for total Arsenic determination. A good agreement was found between these two techniques, demonstrating the accuracy of the TXRF procedure. It was found that the highest concentration corresponded to the root and stems (37 ± 31 μg g-1), followed by the bulbs (11 ± 7 μg g-1), being the smallest level found in the green leaves (4 ± 3 μg g-1). At low As contamination levels of 0.25 μg g-1, a risk for translocation of the toxic element to the edible parts of the onion plants exists. At this level the normal development of the plant is not affected, being the only exception the root length, which is significantly higher in the contaminated treatment. (author)

  20. Study of archaeological ceramics by total-reflection X-ray fluorescence spectrometry: Semi-quantitative approach

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Ruiz, R. [Universidad Autonoma de Madrid, Facultad de Ciencias, Servicio Interdepartamental de Investigacion, Modulo C-9, Laboratorio de TXRF, Crta. Colmenar, Km 15, Cantoblanco, E-28049, Madrid (Spain)], E-mail: ramon.fernandez@uam.es; Garcia-Heras, M. [Instituto de Historia-CSIC, C/Serrano, 13. E-28001, Madrid (Spain); CENIM-CSIC, Avda. Gregorio del Amo, 8. E-28040, Madrid (Spain)

    2007-10-15

    Total-reflection X-ray fluorescence spectrometry has been compared with Instrumental Neutron Activation Analysis in order to test its potential application to the study of archaeological ceramics in the archaeometric field. Two direct solid non-chemical sample preparation procedures have been checked: solid sedimentation and solid chemical homogenization. For sedimentation procedure, total-reflection X-ray fluorescence allows the analysis of the elemental composition with respect to the size fraction but not the average evaluation of the composition. For solid chemical homogenization procedure, total-reflection X-ray fluorescence provides precise (from 0.8% to 27% of coefficient of variation) and accurate results (from 91% to 110% of recovery) for 15 elements (Cr, Hf, Ni, Rb, Al, Ba, Ca, K, Mn, Ti, V, Cu, Ga, Y and Fe) with an easy sample preparation process of the solid clay and without previous chemical treatment. The influence of the particle sizes has been checked by total-reflection X-ray fluorescence sample angle scans and anomalous behaviors have been found for three additional detected elements: As, Sr and Zn, which can be attributed to interference effects of the mineral grain sizes of their associated chemical phases in the total-reflection X-ray fluorescence interference region. The solid chemical homogenization procedure produces data useful for archaeological interpretation, which is briefly illustrated by a case-study. Finally, the decantation procedure data can be also useful for size chemical speciation and, consequently, for alternative environmental total-reflection X-ray fluorescence applications.

  1. Study of archaeological ceramics by total-reflection X-ray fluorescence spectrometry: Semi-quantitative approach

    International Nuclear Information System (INIS)

    Total-reflection X-ray fluorescence spectrometry has been compared with Instrumental Neutron Activation Analysis in order to test its potential application to the study of archaeological ceramics in the archaeometric field. Two direct solid non-chemical sample preparation procedures have been checked: solid sedimentation and solid chemical homogenization. For sedimentation procedure, total-reflection X-ray fluorescence allows the analysis of the elemental composition with respect to the size fraction but not the average evaluation of the composition. For solid chemical homogenization procedure, total-reflection X-ray fluorescence provides precise (from 0.8% to 27% of coefficient of variation) and accurate results (from 91% to 110% of recovery) for 15 elements (Cr, Hf, Ni, Rb, Al, Ba, Ca, K, Mn, Ti, V, Cu, Ga, Y and Fe) with an easy sample preparation process of the solid clay and without previous chemical treatment. The influence of the particle sizes has been checked by total-reflection X-ray fluorescence sample angle scans and anomalous behaviors have been found for three additional detected elements: As, Sr and Zn, which can be attributed to interference effects of the mineral grain sizes of their associated chemical phases in the total-reflection X-ray fluorescence interference region. The solid chemical homogenization procedure produces data useful for archaeological interpretation, which is briefly illustrated by a case-study. Finally, the decantation procedure data can be also useful for size chemical speciation and, consequently, for alternative environmental total-reflection X-ray fluorescence applications

  2. Total reflection x-ray fluorescence spectrometers for multielemental analysis: status of commercial equipment

    International Nuclear Information System (INIS)

    Multi-elemental analysis by total reflection x-ray fluorescence spectrometry has evolved during two decades. At the present there are commercial equipment available for the chemical analysis in all kind of biological and mineral samples. The electronic industry has also been benefited from the scientific and technological developments in the field of TXRF. The basic components of the spectrometers can be summarized as follow: a) excitation source; b) geometric arrangement (optics) for collimation and monochromatization of the primary radiation; c) x-ray detector; d) hardware and software for operation of the instrument, data acquisition and spectral deconvolution to determine the concentrations of the element present in the sample (quantitative analysis). As optional there are manufacturers offering the conventional 45 degrees geometry for direct excitation of bulky liquid or solid samples. Personal communications of the author and the commercial brochures available at the moment of writing this presentation have allowed to list the following type of components used in the TXRF spectrometers for multi-elemental analysis (the devices used in the electronic industry to analyze silicon wafers are excluded). Excitation: high power x-ray tube, output from 1300 to 2000 watts; metal ceramic low power-ray tube, output up to 50 watts. Different anodes are used but molybdenum, tungsten and copper are frequent. The excitation systems can be customized according to the requirements of the laboratory. Detector: Si-Li semi-conductor liquid nitrogen cooled; silicon solid state thermoelectrically cooled (silicon drift detector SDD and Si-PIN diode). Optics: multilayer monochromator of Si-W or Ni-C; double multilayer monochromator. Electronics: spectroscopy amplifier, analog to digital converter adapted to a PC compatible computer with software in Windows environment for the whole operation of the spectrometer and for qualy/quantitative analysis of samples are standards in the

  3. Characterization of urban air pollution by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Besides photochemical smog, particulate air pollution is a constantly growing problem in urban areas. The particulate matter present in pollution events contains often toxic or health impacting elements and is responsible for low visibility, might be triggering respiratory diseases like asthma, and can play an important role in formation or duration of smog events. To characterize particulate pollution in two different cities, samples were taken during intensive field campaigns in Chicago, IL, in 2002 and Phoenix, AZ, in 2001. Both cities experience regularly photochemical smog events as well as particulate pollution, but show very different meteorological and topographical conditions. Therefore it is expected that the particulate composition varies significantly, providing information about different pollution forms. Sampling took place in both cases at elevated locations and had a temporal resolution of 1.5 h and 1 h, respectively. The samples were analyzed by total reflection X-ray fluorescence after digestion of the filter matrix. As expected the elemental composition of particulate matter varied between both cities substantially with Phoenix showing a higher abundance of crustal elements, and Chicago enrichment in anthropogenically produced ones. In both cities diurnal patterns were found, exerting maxima in the morning and minima in the early afternoon. The diurnal pattern was much more regularly and also more strongly pronounced in Phoenix. Phoenix's valley location permits for a more stable nocturnal boundary layer to build up during the night thus trapping particulates efficiently during this time, until mixing occurs in the early morning hours and the residual layer lifts. In Chicago, the diurnal variation was less extreme, but another pattern determines the situation with the lake breeze. The lake breeze corresponds to a shift in wind direction towards the east, i.e. from Lake Michigan during the late morning. It was found that certain elemental species

  4. Determination of lead in clay enameled by X-ray fluorescence technique in Total reflection and by Scanning Electron Microscopy

    International Nuclear Information System (INIS)

    This work has the objective of determining lead free in the glazed commercial stewing pans using the X-ray fluorescence technique in Total reflection (FRX) and the observation and semiquantitative determination of lead by Analytical Scanning Electron Microscopy (ASEM). (Author)

  5. A plastic total internal reflection-based photoluminescence device for enzymatic biosensors

    Science.gov (United States)

    Thakkar, Ishan G.

    Growing concerns for quality of water, food and beverages in developing and developed countries drive sizeable markets for mass-producible, low cost devices that can measure the concentration of contaminant chemicals in water, food, and beverages rapidly and accurately. Several fiber-optic enzymatic biosensors have been reported for these applications, but they exhibit very strong presence of scattered excitation light in the signal for sensing, requiring expensive thin-film filters, and their non-planar structure makes them challenging to mass-produce. Several other planar optical waveguide-based biosensors prove to be relatively costly and more fragile due to constituent materials and the techniques involved in their fabrication. So, a plastic total internal reflection (TIR)-based low cost, low scatter, field-portable device for enzymatic biosensors is fabricated and demonstrated. The design concept of the TIR-based photoluminescent enzymatic biosensor device is explained. An analysis of economical materials with appropriate optical and chemical properties is presented. PMMA and PDMS are found to be appropriate due to their high chemical resistance, low cost, high optical transmittance and low auto-fluorescence. The techniques and procedures used for device fabrication are discussed. The device incorporated a PMMA-based optical waveguide core and PDMS-based fluid cell with simple multi-mode fiber-optics using cost-effective fabrication techniques like molding and surface modification. Several techniques of robustly depositing photoluminescent dyes on PMMA core surface are discussed. A pH-sensitive fluorescent dye, fluoresceinamine, and an O2-sensitive phosphorescent dye, Ru(dpp) both are successfully deposited using Si-adhesive gel-based as well as HydroThane-based deposition methods. Two different types of pH-sensors using two different techniques of depositing fluoresceinamine are demonstrated. Also, the effect of concentration of fluoresceinamine-dye molecules

  6. Controllable transmission and total reflection through an impedance-matched acoustic metasurface

    International Nuclear Information System (INIS)

    A general design paradigm for a novel type of acoustic metasurface is proposed by introducing periodically repeated supercells on a rigid thin plate, where each supercell contains multiple cut-through slits that are filled with materials possessing different refractive indices but the same impedance as that of the host medium. When the wavelength of the incident wave is smaller than the periodicity, the direction of the transmitted wave with nearly unity transmittance can be chosen by engineering the phase discontinuities along the transverse direction. When the wavelength is larger than the periodicity, even though the metasurface is impedance matched to the host medium, most of the incident energy is reflected back and the remaining portion is converted into a surface-bound mode. We show that both the transmitted wave control and the high reflection with the surface mode excitation can be interpreted by a unified analytic model based on mode-coupling theory. Our general design principle not only supplies the functionalities of reflection-type acoustic metasurfaces, but also exhibits unprecedented flexibility and efficiency in various domains of wave manipulation for possible applications in fields like refracting, collimating, focusing or absorbing wave energy. (paper)

  7. Controllable transmission and total reflection through an impedance-matched acoustic metasurface

    KAUST Repository

    Mei, Jun

    2014-12-02

    A general design paradigm for a novel type of acoustic metasurface is proposed by introducing periodically repeated supercells on a rigid thin plate, where each supercell contains multiple cut-through slits that are filled with materials possessing different refractive indices but the same impedance as that of the host medium. When the wavelength of the incident wave is smaller than the periodicity, the direction of the transmitted wave with nearly unity transmittance can be chosen by engineering the phase discontinuities along the transverse direction. When the wavelength is larger than the periodicity, even though the metasurface is impedance matched to the host medium, most of the incident energy is reflected back and the remaining portion is converted into a surface-bound mode. We show that both the transmitted wave control and the high reflection with the surface mode excitation can be interpreted by a unified analytic model based on mode-coupling theory. Our general design principle not only supplies the functionalities of reflection-type acoustic metasurfaces, but also exhibits unprecedented flexibility and efficiency in various domains of wave manipulation for possible applications in fields like refracting, collimating, focusing or absorbing wave energy.

  8. Determination of Optical Constants in the Mid-Infrared Spectral Range by use of the Attenuated Total Reflection Method

    OpenAIRE

    Biliškov, N.

    2010-01-01

    Infrared (IR) spectroscopy is one of the most useful experimental methods in the investigation of hydrogen-bonded systems. However, application of transmission IR spectroscopy to aqueous systems is only of limited value due to the very strong water absorption. The necessity of very short pathlengths to obtain quantitative spectra is accompanied by very low reproducibility of the spectra obtained in such a way. However, in the last two decades, a reliable procedure which allows the calculation...

  9. Rapid evaluation and quantitative analysis of eugenol derivatives in essential oils and cosmetic formulations on human skin using attenuated total reflectance–infrared spectroscopy

    OpenAIRE

    Wang, Lai-Hao; Sung, Wei-Chien

    2011-01-01

    We studied the fragrances 4-allylbenzenes (eugenol, methyl eugenol, acetyl eugenol) as well as 4-propenylbenzenes (isoeugenol) in commercial essential oils using a fast and nondestructive attenuated total reflectance–infrared (ATR–IR) spectroscopy method. The method was based on ATR–IR utilizing partial least square regression. The calibrations were modeled in the characteristic region for eugenol (1430–1432 cm−1), isoeugenol (960–970 cm−1) and methyl eugenol (803–807 cm−1). The models were t...

  10. On the tunneling of full-vector X-Waves through a slab under frustrated total reflection condition

    KAUST Repository

    Salem, Mohamed

    2012-07-01

    Tunneling of full-vector X-Waves through a dielectric slab under frustrated total reflection condition is investigated. Full-vector X-Waves are obtained by superimposing transverse electric and magnetic polarization components, which are derived from the scalar X-Wave solution. The analysis of reflection and transmission at the dielectric interfaces is carried out analytically in a straightforward fashion using vector Bessel beam expansion. Investigation of the fields propagating away from the farther end of the slab (transmitted fields) shows an advanced (superluminal) transmission of the X-Wave peak. Additionally, a similar advanced reflection is also observed. The apparent tunneling of the peak is shown to be due to the phase shift in the fields\\' spectra and not to be causally related to the incident peak. © 2012 IEEE.

  11. Assessment of serum selenium levels in 2-month-old sucking calves using Total Reflection Technique

    International Nuclear Information System (INIS)

    The assessment of selenium status of livestock is an important aspect of production medicine as evidence for the influence of low Se levels on disease resistance in ruminants is reviewed with emphasis on susceptibility to various pathologies (such as infections, exudative diathesis, pneumonia, pancreatic degeneration). Additional evidence suggests that Se deficiency may cause muscular dystrophy in calves, while, severe deficiency has been associated with cardiomyopathy and even death. Serum Se content is a good indicator of the short term Se status and reflects the recent dietary intake of the element. Since Serum Se content is a good indicator of the short term status of the element and reflects the its recent dietary intake, the present work is aimed to determine Se concentration in serum from a group of 2 month old sucking calves suspected to be severely deficient. We used the TX 2000 X-ray spectrometer manufactured by Ital Structures. The energy resolution (FWHM) of the Si(Li) detector was 137 eV for Mn Kα. Among nuclear techniques the TXRF method is the best suitable for trace element analysis in liquid or dissolved samples and can deal much easier with elemental investigation. Physical basis of used analytical method, experimental set up and the sample preparation procedure are described. The concentration data obtained are presented and discussed

  12. Assessment of serum selenium levels in 2-month-old sucking calves using total reflection technique

    International Nuclear Information System (INIS)

    The assessment of selenium status of livestock is an important aspect of production medicine as evidence for the influence of low Se levels on disease resistance in ruminants is reviewed with emphasis on susceptibility to various pathologies (such as infections, exudative diathesis, pneumonia, pancreatic degeneration). Additional evidence suggests that Se deficiency may cause muscular dystrophy in calves, while, severe deficiency has been associated with cardiomyopathy and even death. Serum Se content is a good indicator of the short term Se status and reflects the recent dietary intake of the element. Since serum Se content is a good indicator of the short term status of the element and reflects the its recent dietary intake, the present work is aimed to determine Se concentration in serum from a group of 2 months old sucking calves suspected to be severely deficient. We used the TX 2000 X-ray spectrometer manufactured by Ital Structures. The energy resolution (FWHM) of the Si(Li) detector was 137 eV for Mn Kα. Among nuclear techniques the TXRF method is the best suitable for trace element analysis in liquid or dissolved samples and can deal much easier with elemental investigation. Physical basis of used analytical method, experimental set up and the sample preparation procedure are described. The concentration data obtained are presented and discussed. (author)

  13. 1. Latin American Workshop on Total Reflection X-Ray Fluorescence (TXRF) and its Applications: TARABANA 99. Programme and Abstracts

    International Nuclear Information System (INIS)

    It concerns about the advances in Total Reflection X-Ray Fluorescence (TXRF) instrumentation; structure, characteristic and potential of TXRF equipment used for chemical multielemental survey; TXRF: an approach to nano analysis; microanalytical investigation of environmental samples by TXRF spectrometry; TXRF of low Z elements; assessment of serum selenium levels in 2 month old sucking calves using TXRF: A powerful method to investigate the elemental composition of spheroids; environmental applications of TXRF; use of modifiers for the elimination in situ of chlorides in the analysis of TXRF; experimental methodology and analysis spectra for the determination of mercury by means of TXRF using amalgamation with gold; multielemental analysis of human amniotic fluid by use of Total Reflection X-Ray Fluorescence and rutherford forward scattering; determination of metal in samples of handmade penca; determination of oligo elements, platinum and relationship Zn/Cu in samples of blood serum and urine in oncological pediatric patient

  14. Total Reducing Capacity in Aquifer Minerals and Sediments: Quantifying the Potential to Attenuate Cr(VI) in Groundwater

    Energy Technology Data Exchange (ETDEWEB)

    Sisman, S. Lara [Univ. of Virginia, Charlottesville, VA (United States); Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-07-20

    Hexavalent chromium, Cr(VI), is present in the environment as a byproduct of industrial processes. Due to its mobility and toxicity, it is crucial to attenuate or remove Cr(VI) from the environment. The objective of this investigation was to quantify potential natural attenuation, or reduction capacity, of reactive minerals and aquifer sediments. Samples of reduced-iron containing minerals such as ilmenite, as well as Puye Formation sediments representing a contaminated aquifer in New Mexico, were reacted with chromate. The change in Cr(VI) during the reaction was used to calculate reduction capacity. This study found that minerals that contain reduced iron, such as ilmenite, have high reducing capacities. The data indicated that sample history may impact reduction capacity tests due to surface passivation. Further, this investigation identified areas for future research including: a) refining the relationships between iron content, magnetic susceptibility and reduction capacity, and b) long term kinetic testing using fresh aquifer sediments.

  15. Total Reducing Capacity in Aquifer Minerals and Sediments: Quantifying the Potential to Attenuate Cr(VI) in Groundwater

    International Nuclear Information System (INIS)

    Hexavalent chromium, Cr(VI), is present in the environment as a byproduct of industrial processes. Due to its mobility and toxicity, it is crucial to attenuate or remove Cr(VI) from the environment. The objective of this investigation was to quantify potential natural attenuation, or reduction capacity, of reactive minerals and aquifer sediments. Samples of reduced-iron containing minerals such as ilmenite, as well as Puye Formation sediments representing a contaminated aquifer in New Mexico, were reacted with chromate. The change in Cr(VI) during the reaction was used to calculate reduction capacity. This study found that minerals that contain reduced iron, such as ilmenite, have high reducing capacities. The data indicated that sample history may impact reduction capacity tests due to surface passivation. Further, this investigation identified areas for future research including: a) refining the relationships between iron content, magnetic susceptibility and reduction capacity, and b) long term kinetic testing using fresh aquifer sediments.

  16. Progress of standardization activity of Total reflection X-Ray Fluorescence method ISO TC 201 W62

    International Nuclear Information System (INIS)

    The measurement of metal impurities on the surface of silicon wafer by Total reflection X-Ray Fluorescence is commonly accepted by the semiconductor industry ISO TC 201 W62 was organized in 1993 as a secretary country in Japan ISO 14706 specified a Total reflection X-Ray Fluorescence method for measurements of metal impurities on the silicon wafer surface with atomic surface density from 1x1010 atoms/cm2 to 1x1014 atoms/cm2 at Dec 2000. In ULSI manufacturing, the measurements for metal impurities of less than 1010 atoms/cm2 are currently required on the silicon wafer of Total reflection X-Ray Fluorescence chemical preparation method (DADD) has been adopted to collected and concentrate metal impurities into a small area on the surface of silicon wafer. In order to certificate the accuracy of quantification of metal impurities in the drying residue that is obtained by chemical preparation method we are going to specify this chemical preparation method. The results of the firsts round robin test RRT) carried out with three experimental conditions depended on each laboratories had pretty big measurement error the second RRT was done under the experimental conditions used with the recovery solution of HF(2%) H2O2(2%) and the addition of vanadium of scandium as a internal standard. 20 Laboratories (Japan: 11, US: 3, Europe: 6)gave a combination of the chemical preparation method and Total reflection X-Ray Fluorescence, AAS or ICP-MS results good reproducibility of less than 20 % Cv and repeatability of less than 10 % Cv

  17. Application of a CdTe solid-state detector to polarization-dependent total-reflection fluorescence XAFS measurements

    International Nuclear Information System (INIS)

    A CdTe solid-state detector was applied to the measurement of polarization-dependent total-reflection fluorescence XAFS spectra. The data revealed that the detector has good sensitivity, and this, together with its compact size, make it appropriate for in-situ measurements and removal of X-ray Bragg diffraction. The detector efficiently recorded the high-energy K-edge XAFS spectra for molybdenum oxides supported on TiO2 (110). (au) 10 refs

  18. Investigation of effect of different total area coverage values of inks on reflection spectra and color gamut

    Science.gov (United States)

    Spiridonov, I.; Shopova, M.; Boeva, R.

    2013-03-01

    The paper presents investigation of the effect of different values of total area coverage of inks (TAC) on reflection spectra and color gamut. Total area coverage is a key factor for achieving of maximal volume of color gamut. The reflection spectra of color surfaces in entire visible spectrum are used for determination the effect of different values of TAC. For study the effect of TAC values on color gamut, we have used special test form that contains many components and test charts with over 1500 color patches. According to measurement of reflectance spectrum of test charts, we have compared the color gamuts with different values of TAC to obtain comprehensive information of all colors, which could be reproduced in the specific conditions. In addition we have converted the reflection spectra data to CIE L*a*b* coordinates, and we have calculated the color difference ΔE* ab to determine the effect of TAC on color reproduction accuracy. The main goal of this study is development of methodology, which gives objective and analytical assessment, for determining the optimal value of total area coverage (TAC). A practical implementation of the correct and optimal value of total area coverage should improve the printability, better ink layers adhesion, biggest number of trapping values and reduce the quantity of process inks. The optimal value of the TAC determined by this new methodology helps to achieve a significant reduction of ink cost and a maximal color gamut volume, i.e. improve the quality of printed image and reduce financial costs.

  19. Methods for the measurement of the refractive index of MeV photons using total internal and external reflection

    International Nuclear Information System (INIS)

    Recently it has been theoretically and experimentally shown that for 1-10 MeV and 1-2 MeV photons, respectively, the refractive index of Si is greater than 1. Taking into account the difficulties of the carried out experiment it is proposed to measure directly the refractive index of Si and other materials detecting the total internal and external reflections.

  20. Effect of weight fraction of different constituent elements on the total mass attenuation coefficients of biological materials

    Indian Academy of Sciences (India)

    Karamjit Singh; Charanjeet Singh; Parjit S Singh; Gurmel S Mudahar

    2002-07-01

    The mass attenuation coefficients, m, of biological materials have been studied as a function of weight fraction of constituent elements (hydrogen, carbon, oxygen and nitrogen). A considerable change in m is seen only in low energy region whereas no change is observed with the increasing percentage of constituent elements in high energy region up to 10 MeV. The results have been presented in graphical form.

  1. Mapping of healthy oral mucosal tissue using diffuse reflectance spectroscopy: ratiometric-based total hemoglobin comparative study.

    Science.gov (United States)

    Hafez, Razan; Hamadah, Omar; Bachir, Wesam

    2015-11-01

    The objective of this study is to clinically evaluate the diffuse reflectance spectroscopy (DRS) ratiometric method for differentiation of normal oral mucosal tissues with different histological natures and vascularizations in the oral cavity. Twenty-one healthy patients aged 20-44 years were diagnosed as healthy and probed with a portable DRS system. Diffuse reflectance spectra were recorded in vivo in the range (450-650 nm). In this study, the following three oral mucosal tissues were considered: masticatory mucosa, lining mucosa, and specialized mucosa. Spectral features based on spectral intensity ratios were determined at five specific wavelengths (512, 540, 558, 575, and 620 nm). Total hemoglobin based on spectral ratios for the three anatomical regions have also been evaluated. The three studied groups representing different anatomical regions in the oral cavity were compared using analysis of variance and post hoc least significant difference tests. Statistical analysis showed a significant difference in the mean of diffuse spectral ratios between the groups (P oral sites in terms of total hemoglobin content. Diffuse reflectance spectroscopy might be used for creating a DRS databank of normal oral mucosal tissue with specific spectral ratios featuring the total hemoglobin concentrations. That would further enhance the discrimination of oral tissue for examining the histological nature of oral mucosa and diagnosis of early precancerous changes in the oral cavity based on non-invasive monitoring of neovascularization. PMID:25987341

  2. Surface characterization of selected polymer thin films by total-reflection x-ray fluorescence spectroscopy and x-ray reflectivity

    International Nuclear Information System (INIS)

    Development of available x-ray characterizations tools for grazing incidence techniques was done to be able to probe nano-size thin films. Alignment of a Philips x-ray powder diffractometer was improved to let it perform as an x-ray reflectometer. X-ray reflectometry was coupled with total-reflection x-ray fluorescence spectroscopy. Evaluation of the performance of this grazing incidence techniques was done by preparing polymer thin films of carboxymethylcellulose, carrageenan and polyvinylpyrrolidone (PVP). The thickness of the films were varied by varying the process parameters such as concentration, spin speed and spin time. Angle-dispersive total-reflection x-ray fluorescence spectroscopy profiles of three films showed film formation only in carrageenan and PVP. For both carrageenan and PVP, an increase in concentration yielded a corresponding increase in intensity of the fluorescent or scattered peaks. XRR profiles of carrageenan thin films yielded a mean value for the critical angle close to quartz substrate. Thickness measurements of the prepared carrageenan thin films showed that concentration was the main determinant for final film thickness over the other process parameters. Sulfur fluorescent intensity derived from the TXRF measurement showed a linear relationship with the measured thickness by XRR. For PVP, measured critical angle is lower than quartz. Poor adhesion of the polymer onto the substrate yielded a limited number of thickness measurements made from the XRR profiles. (Author)

  3. A Theory of Intelligence and Total Factor Productivity: Value Added Reflects the Fruits of Fluid Intelligence

    OpenAIRE

    Harashima, Taiji

    2012-01-01

    In this paper, a theory of total factor productivity (TFP) that incorporates a model of intelligence is formulated and described. In particular, the fluid intelligence of ordinary workers is emphasized as an important element in TFP because such workers have the intelligence to innovate, even though their innovations are minor. Nevertheless, these innovations are essential for production because they solve many small but unexpected problems that ordinary workers must address. The TFP model is...

  4. l-Citrulline supplementation attenuates blood pressure, wave reflection and arterial stiffness responses to metaboreflex and cold stress in overweight men.

    Science.gov (United States)

    Figueroa, Arturo; Alvarez-Alvarado, Stacey; Jaime, Salvador J; Kalfon, Roy

    2016-07-01

    Combined isometric exercise or metaboreflex activation (post-exercise muscle ischaemia (PEMI)) and cold pressor test (CPT) increase cardiac afterload, which may lead to adverse cardiovascular events. l-Citrulline supplementation (l-CIT) reduces systemic arterial stiffness (brachial-ankle pulse wave velocity (baPWV)) at rest and aortic haemodynamic responses to CPT. The aim of this study was to determine the effect of l-CIT on aortic haemodynamic and baPWV responses to PEMI+CPT. In all, sixteen healthy, overweight/obese males (age 24 (sem 6) years; BMI 29·3 (sem 4·0) kg/m2) were randomly assigned to placebo or l-CIT (6 g/d) for 14 d in a cross-over design. Brachial and aortic systolic blood pressure (SBP), diastolic blood pressure (DBP) and mean arterial pressure (MAP), aortic augmented pressure (AP), augmentation index (AIx), baPWV, reflection timing (Tr) and heart rate (HR) were evaluated at rest and during isometric handgrip exercise (IHG), PEMI and PEMI+CPT at baseline and after 14 d. No significant effects were evident after l-CIT at rest. l-CIT attenuated the increases in aortic SBP and wave reflection (AP and AIx) during IHG, aortic DBP, MAP and AIx during PEMI, and aortic SBP, DBP, MAP, AP, AIx and baPWV during PEMI+CPT compared with placebo. HR and Tr were unaffected by l-CIT in all conditions. Our findings demonstrate that l-CIT attenuates aortic blood pressure and wave reflection responses to exercise-related metabolites. Moreover, l-CIT attenuates the exaggerated arterial stiffness response to combined metaboreflex activation and cold exposure, suggesting a protective effect against increased cardiac afterload during physical stress. PMID:27160957

  5. Recent results of synchrotron radiation induced total reflection X-ray fluorescence analysis at HASYLAB, beamline L

    Energy Technology Data Exchange (ETDEWEB)

    Streli, C. [Atominstitut, Vienna University of Technology, Stadionallee 2, A-1020 Vienna (Austria)]. E-mail: streli@ati.ac.at; Pepponi, G. [ITC-irst, Povo (Italy); Wobrauschek, P. [Atominstitut, Vienna University of Technology, Stadionallee 2, A-1020 Vienna (Austria); Jokubonis, C. [Atominstitut, Vienna University of Technology, Stadionallee 2, A-1020 Vienna (Austria); Falkenberg, G. [Hamburger Synchrotronstrahlungslabor at Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, D-22603 Hamburg (Germany); Zaray, G. [Institute of Inorganic and Applied Chemistry, 3 EOTVOS Univ, Budapest (Hungary); Broekaert, J. [Institute of Anorganic and Applied Chemistry, University Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany); Fittschen, U. [Institute of Anorganic and Applied Chemistry, University Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany); Peschel, B. [Institute of Anorganic and Applied Chemistry, University Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany)

    2006-11-15

    At the Hamburger Synchrotronstrahlungslabor (HASYLAB), Beamline L, a vacuum chamber for synchrotron radiation-induced total reflection X-ray fluorescence analysis, is now available which can easily be installed using the adjustment components for microanalysis present at this beamline. The detector is now in the final version of a Vortex silicon drift detector with 50-mm{sup 2} active area from Radiant Detector Technologies. With the Ni/C multilayer monochromator set to 17 keV extrapolated detection limits of 8 fg were obtained using the 50-mm{sup 2} silicon drift detector with 1000 s live time on a sample containing 100 pg of Ni. Various applications are presented, especially of samples which are available in very small amounts: As synchrotron radiation-induced total reflection X-ray fluorescence analysis is much more sensitive than tube-excited total reflection X-ray fluorescence analysis, the sampling time of aerosol samples can be diminished, resulting in a more precise time resolution of atmospheric events. Aerosols, directly sampled on Si reflectors in an impactor were investigated. A further application was the determination of contamination elements in a slurry of high-purity Al{sub 2}O{sub 3}. No digestion is required; the sample is pipetted and dried before analysis. A comparison with laboratory total reflection X-ray fluorescence analysis showed the higher sensitivity of synchrotron radiation-induced total reflection X-ray fluorescence analysis, more contamination elements could be detected. Using the Si-111 crystal monochromator also available at beamline L, XANES measurements to determine the chemical state were performed. This is only possible with lower sensitivity as the flux transmitted by the crystal monochromator is about a factor of 100 lower than that transmitted by the multilayer monochromator. Preliminary results of X-ray absorption near-edge structure measurements for As in xylem sap from cucumber plants fed with As(III) and As(V) are

  6. Total reflection X-ray fluorescence analysis of trace-elements in candies marketed in Mexico

    International Nuclear Information System (INIS)

    Trace metals concentrations in food are significant for nutrition, due either to their nature or toxicity. Sweets, including chewing gum and candies, are not exactly a food, but they usually are unwearied consumed by children, the most vulnerable age-group to any kind of metal contamination in the food chain. The presence of relatively high concentrations of heavy metals such as Lead elicits concern since children are highly susceptible to heavy metals poisoning. Trace-metals concentrations were determined for six different flavors of a Mexican candy by means of Total X-ray Fluorescence Spectrometry. Triplicate samples of the various candy's flavours (strawberry, pineapple, lemon, blackberry, orange and chilli) were digested in 8 mL of a mix of supra-pure HNO3 and H2O2 (6 mL: 2 mL) in a microwave oven MARS-X. Results show the presence of essential and toxic elements such as Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, and Pb. All metal concentrations were higher and significantly different (α = 0.05) in chilli candy, compared to other candy flavours. Lead concentration fluctuated in the range of 0.102 to 0.342 μg g-1. A discussion about risk consumption and concentration allowed by Mexican and International Norms is made. As a part of the Quality Control Program, a NIST standard of 'Citrus Leaves' and a blank were treated in the same way.

  7. Total reflection X-ray fluorescence analysis of trace-elements in candies marketed in Mexico

    Science.gov (United States)

    Martinez, T.; Lartigue, J.; Zarazua, G.; Avila-Perez, P.; Navarrete, M.; Tejeda, S.

    2010-06-01

    Trace metals concentrations in food are significant for nutrition, due either to their nature or toxicity. Sweets, including chewing gum and candies, are not exactly a food, but they usually are unwearied consumed by children, the most vulnerable age-group to any kind of metal contamination in the food chain. The presence of relatively high concentrations of heavy metals such as Lead elicits concern since children are highly susceptible to heavy metals poisoning. Trace-metals concentrations were determined for six different flavors of a Mexican candy by means of Total X-ray Fluorescence Spectrometry. Triplicate samples of the various candy's flavours (strawberry, pineapple, lemon, blackberry, orange and chilli) were digested in 8 mL of a mix of supra-pure HNO 3 and H 2O 2 (6 mL: 2 mL) in a microwave oven MARS-X. Results show the presence of essential and toxic elements such as Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, and Pb. All metal concentrations were higher and significantly different ( α = 0.05) in chilli candy, compared to other candy flavours. Lead concentration fluctuated in the range of 0.102 to 0.342 μg g - 1 . A discussion about risk consumption and concentration allowed by Mexican and International Norms is made. As a part of the Quality Control Program, a NIST standard of "Citrus Leaves" and a blank were treated in the same way.

  8. Quantitative Analysis of Total Petroleum Hydrocarbons in Soils: Comparison between Reflectance Spectroscopy and Solvent Extraction by 3 Certified Laboratories

    Directory of Open Access Journals (Sweden)

    Guy Schwartz

    2012-01-01

    Full Text Available The commonly used analytic method for assessing total petroleum hydrocarbons (TPH in soil, EPA method 418.1, is usually based on extraction with 1,1,2-trichlorotrifluoroethane (Freon 113 and FTIR spectroscopy of the extracted solvent. This method is widely used for initial site investigation, due to the relative low price per sample. It is known that the extraction efficiency varies depending on the extracting solvent and other sample properties. This study’s main goal was to evaluate reflectance spectroscopy as a tool for TPH assessment, as compared with three commercial certified laboratories using traditional methods. Large variations were found between the results of the three commercial laboratories, both internally (average deviation up to 20%, and between laboratories (average deviation up to 103%. Reflectance spectroscopy method was found be as good as the commercial laboratories in terms of accuracy and could be a viable field-screening tool that is rapid, environmental friendly, and cost effective.

  9. Total reflection X-ray fluorescence analysis of trace-elements in candies marketed in Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, T., E-mail: tmc@servidor.unam.m [Facultad de Quimica, Departamento de Quimica Inorganica y Nuclear. Universidad Nacional Autonoma de Mexico, Mexico D.F. 04510 (Mexico); Lartigue, J. [Facultad de Quimica, Departamento de Quimica Inorganica y Nuclear. Universidad Nacional Autonoma de Mexico, Mexico, D.F. 04510 (Mexico); Zarazua, G.; Avila-Perez, P. [National Institute of Nuclear Research. Ocoyoacac, Edo. de Mexico, 05045 (Mexico); Navarrete, M. [Facultad de Quimica, Departamento de Quimica Inorganica y Nuclear. Universidad Nacional Autonoma de Mexico, Mexico, D.F. 04510 (Mexico); Tejeda, S. [National Institute of Nuclear Research. Ocoyoacac, Edo. de Mexico, 05045 (Mexico)

    2010-06-15

    Trace metals concentrations in food are significant for nutrition, due either to their nature or toxicity. Sweets, including chewing gum and candies, are not exactly a food, but they usually are unwearied consumed by children, the most vulnerable age-group to any kind of metal contamination in the food chain. The presence of relatively high concentrations of heavy metals such as Lead elicits concern since children are highly susceptible to heavy metals poisoning. Trace-metals concentrations were determined for six different flavors of a Mexican candy by means of Total X-ray Fluorescence Spectrometry. Triplicate samples of the various candy's flavours (strawberry, pineapple, lemon, blackberry, orange and chilli) were digested in 8 mL of a mix of supra-pure HNO{sub 3} and H{sub 2}O{sub 2} (6 mL: 2 mL) in a microwave oven MARS-X. Results show the presence of essential and toxic elements such as Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, and Pb. All metal concentrations were higher and significantly different ({alpha} = 0.05) in chilli candy, compared to other candy flavours. Lead concentration fluctuated in the range of 0.102 to 0.342 {mu}g g{sup -1}. A discussion about risk consumption and concentration allowed by Mexican and International Norms is made. As a part of the Quality Control Program, a NIST standard of 'Citrus Leaves' and a blank were treated in the same way.

  10. A method for thickness determination of thin films of amalgamable metals by total-reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    A method for thickness determination of thin amalgamable metallic films by total-reflection X-ray fluorescence (TXRF) is presented. The peak's intensity in TXRF spectra are directly related to the surface density of the sample, i.e. to its thickness in a homogeneous film. Performing a traditional TXRF analysis on a thin film of an amalgamated metal, and determining the relative peak intensity of a specific metal line, the layer thickness can be precisely obtained. In the case of gold thickness determination, mercury and gold peaks overlap, hence we have developed a general data processing scheme to achieve the most precise results.

  11. High accuracy subwavelength distance measurements: A variable-angle standing-wave total-internal-reflection optical microscope

    International Nuclear Information System (INIS)

    We describe an extension of the total-internal-reflection microscopy technique that permits direct in-plane distance measurements with high accuracy (<10 nm) over a wide range of separations. This high position accuracy arises from the creation of a standing evanescent wave and the ability to sweep the nodal positions (intensity minima of the standing wave) in a controlled manner via both the incident angle and the relative phase of the incoming laser beams. Some control over the vertical resolution is available through the ability to scan the incoming angle and with it the evanescent penetration depth.

  12. Multiplex detection of histone-modifying enzymes by total internal reflection fluorescence-based single-molecule detection.

    Science.gov (United States)

    Ma, Fei; Liu, Meng; Wang, Zi-yue; Zhang, Chun-yang

    2016-01-21

    We develop a sensitive and selective method for the multiplex detection of histone-modifying enzymes (HMEs) through the integration of antibody-based fluorescence labeling with total internal reflection fluorescence (TIRF)-based single-molecule detection. This method exhibits excellent specificity and high sensitivity with a detection limit of 21 pM for histone acetyltransferase GcN5 and 12 pM for histone methyltransferase G9a, and it can be applied for the screening of HME inhibitors as well. PMID:26608941

  13. Ganoderma lucidum total triterpenes attenuate DLA induced ascites and EAC induced solid tumours in Swiss albino mice.

    Science.gov (United States)

    Smina, T P; Mathew, J; Janardhanan, K K

    2016-01-01

    G. lucidum total triterpenes were assessed for its apoptosis-inducing and anti-tumour activities. The ability of the total triterpenes to induce apoptosis was evaluated in Dalton's lymphoma ascites (DLA) and Ehrlich's ascites carcinoma (EAC) cell lines. Total triterpenes were found to be highly cytotoxic to DLA and EAC cell lines with IC50 values 5 ± 0.32 and 7.9 ± 0.2 µg/ml respectively. Total triterpenes induced apoptosis in both cell lines which is evident from the DNA fragmentation assay. Anti-tumour activity was accessed using DLA induced solid and EAC induced ascites tumour models in Swiss albino mice. Administration of 10, 50 and 100 mg/kg b. wt. total triterpenes showed 11.86, 27.27 and 40.57% increase in life span of animals in ascites tumour model. Treatment with 10, 50 and 100 mg/kg b. wt. total triterpenes exhibited 76.86, 85.01 and 91.03% inhibition in tumour volume and 67.96, 72.38 and 77.90% inhibition in tumour weight respectively in the solid tumour model. The study reveals the significant dose-dependent anti-tumour activity of total triterpenes in both models. Total triterpenes were more active against the solid tumour than the ascites tumour. The anti-oxidant potential and ability to induce cell-specific apoptosis could be contributing to its anti-tumour activities. PMID:27188870

  14. Approximate analytical formulas for total cross sections and for mass attenuation coefficients of narrow gamma beams for 3 to 100 MeV

    International Nuclear Information System (INIS)

    Tabulated data by Storm and Israel for total cross sections and mass attenuation coefficients for narrow gamma beams of 3 to 100 MeV and elements with Z equal to 26 to 94 were approximated by an analytical formula analogous to the ultrarelativistic case of Compton scattering and pair creation. The reproduction accuracy of the tabulated data is better than 1 to 2% in a region of 3 to 60 MeV and better than 3 to 4% from 60 to 100 MeV. In the analytical formula three constants were needed for each Z, the tables of which are given. (author)

  15. Total reflection X-ray fluorescence analysis of river waters in its stream across the city of Cordoba, in Argentina

    International Nuclear Information System (INIS)

    The aim of this work was to analyze the composition of river waters and to study their quality by detecting possible contaminants. The samples were taken at 32 points of the Suquia River in its stream across the city of Cordoba (in the Province of Cordoba, Argentina). The samples were analyzed with total reflection X-ray fluorescence (TXRF) using beam guides. Beam guides made of two Si plate reflectors were used as sample carriers and to guide the X-ray photons to the sample; the measurements were taken using the characteristic configuration that ensures the best excitation and detection conditions (in TXRF). The analyses were carried out by preconcentration of the water samples and by adding an internal standard (Gallium); small amounts of samples (30 μl) were deposited on the Si reflector plate and they were then analyzed in the total reflection regime. Spectra were analyzed with standard methods using conventional programs. The results show interesting behaviors of the concentration of trace elements along the river: elements of low atomic number (such as Ca, Cl, S, K) present higher concentrations as compared to high Z elements (such as Fe, Zn, Br, Sr); the concentrations of light elements follow a similar behavior along the stream, the same situation is observed in the set of elements with high atomic number. Some samples present high concentrations in certain elements indicating possible sources of contamination

  16. Clonorchis sinensis-derived total protein attenuates airway inflammation in murine asthma model by inducing regulatory T cells and modulating dendritic cell functions

    International Nuclear Information System (INIS)

    Highlights: → Treatment with Clonorchis sinensis-derived total protein attenuates OVA-induced airway inflammation and AHR to methacholine. → Induction of CD4+CD25+Foxp3+ T cells and IL-10 along with suppression of splenocyte proliferation by C. sinensis-derived total protein. → C. sinensis-derived total protein interferes with the expression of co-stimulatory molecules in DCs. -- Abstract: Asthma is characterized by Th2-mediated inflammation, resulting in airway hyperresponsiveness (AHR) through airway remodeling. Recent epidemiological and experimental reports have suggested an inverse relationship between the development of allergy and helminth infections. Infection by Clonorchis sinensis, a liver fluke that resides in the bile duct of humans, is endemic predominantly in Asia including Korea and China. Using a murine model for asthma, we investigated the effects of C. sinensis-derived total protein (Cs-TP) on allergen-induced airway inflammation and the mechanism underlying the protective effects of Cs-TP administration on asthma. Treatment with Cs-TP attenuated OVA-induced airway inflammation and methacholine-induced AHR, as well as eosinophilia development, lymphocyte infiltration into the lung, and goblet cell metaplasia. This protective effect of Cs-TP is associated with markedly reduced OVA-specific IgE and Th1/Th2 cytokine production. Moreover, Cs-TP increased the number of CD4+CD25+Foxp3+ regulatory T (Treg) cells as well as their suppressive activity. In fact, proliferation of OVA-restimulated splenocytes was suppressed significantly. Cs-TP also inhibited the expression of such co-stimulatory molecules as CD80, CD86, and CD40 in LPS- or OVA-stimulated dendritic cells (DCs), suggesting that Cs-TP could interfere with the capacity of airway DCs to prime naive T cells. These data demonstrate the capacity of C. sinensis to ameliorate allergic asthma and broaden our understanding of the paradoxical relationship between the allergic immune response and

  17. Seasonal variation in trace and minor elements in Brazilian honey by total reflection X-ray fluorescence.

    Science.gov (United States)

    de Oliveira Resende Ribeiro, Roberta; Mársico, Eliane Teixeira; da Silva Carneiro, Carla; Simoes, Julia Siqueira; da Silva Ferreira, Micheli; de Jesus, Edgar Francisco Oliveira; Almeida, Eduardo; Junior, Carlos Adam Conte

    2015-03-01

    Honey is used as an alternative medicine and is a constituent of a healthy diet worldwide. Its composition is associated with botanical origin and, to some extent, geographical origin because soil and climate characteristics determine the melliferous flora. Also, the elements content in honey samples could give an indication of environmental pollution or geographical origin. The main purpose of this study was to evaluate seasonal patterns of essential elements of Brazilian honey. Honey was collected during spring, summer, autumn, and winter for 2 years to quantify K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Se, Br, and Sr using total reflection X-ray fluorescence spectroscopy (TXRF). Our results indicate no seasonal differences in concentration of Cr, Ni, Se, and Ti, although there were significant seasonal patterns in the composition of essential elements in honey, with higher concentrations of minor and trace elements, especially K and Ca of samples collected in spring and summer. PMID:25663399

  18. Multielement analysis by total reflection X-ray fluorescence spectrometry for the certification of lichen research material

    International Nuclear Information System (INIS)

    Total reflection X-ray fluorescence spectrometry was applied for the certification of IAEA lichen-336. The elements Ca, Mn, Fe, Cu, Zn, Rb, Sr and Pb were determined simultaneously. The concentrations range from 1.8 mg/kg for Rb to 2360 mg/kg for Ca. The results were compared with those of other methods and laboratories having participated in this certification for the International Atomic Energy Agency (IAEA): emission spectrometry, mass spectrometry, atomic absorption spectrometry, X-ray spectrometry, neutron activation analysis and voltammetry. The results determined by TXRF are in good agreement with the overall means of accepted values and differ from the means by 1 to 10%. (orig.). With 2 figs., 1 tab

  19. Fish samples as bioindicator of environmental quality: synchrotron radiation total reflection X-ray fluorescence analysis (SR-TXRF)

    International Nuclear Information System (INIS)

    In this study fish were used as bioindicators of environmental contamination. The species were collected in Piracicaba River, Sao Paulo state, Brazil and the toxic elements concentrations were determined in muscle tissue and viscus (liver, intestine and stomach) by Synchrotron Radiation Total Reflection X-Ray Fluorescence Analysis (SR-TXRF). Were determined the elements Ti, Cr, Mn, Fe, Ni, Cu, Zn and Ba. The results were compared with values established by Brazilian Legislation for general food. The elements concentrations evidenced potential risk to human health and environmental quality alteration of the studied area. The measurements were realized at the 'Laboratorio Nacional de Luz Sincrotron' (LNLS) located in Campinas, Sao Paulo State, Brazil. (author)

  20. In-situ analysis of fruit anthocyanins by means of total internal reflectance, continuous wave and time-resolved spectroscopy

    Science.gov (United States)

    Zude, Manuela; Spinelli, Lorenzo; Dosche, Carsten; Torricelli, Alessandro

    2009-08-01

    In sweet cherry (Prunus avium), the red pigmentation is correlated with the fruit maturity stage and can be measured by non-invasive spectroscopy. In the present study, the influence of varying fruit scattering coefficients on the fruit remittance spectrum (cw) were corrected with the effective pathlength and refractive index in the fruit tissue obtained with distribution of time-of-flight (DTOF) readings and total internal reflection fluorescence (TIRF) analysis, respectively. The approach was validated on fruits providing variation in the scattering coefficient outside the calibration sample set. In the validation, the measuring uncertainty when non-invasively analyzing fruits with cw method in comparison with combined application of cw, DTOF, and TIRF measurements showed an increase in r2 up to 22.7 % with, however, high errors in all approaches.

  1. A total internal reflection fluorescence microscopy study of mass diffusion enhancement in water-based alumina nanofluids

    Science.gov (United States)

    Veilleux, Jocelyn; Coulombe, Sylvain

    2010-11-01

    Mass diffusion of rhodamine 6G (R6G) in water-based alumina nanofluids is studied by means of total internal reflection fluorescence (TIRF) microscopy. We report a mass diffusivity enhancement that reaches an order of magnitude in a 2 vol % nanofluid when compared to the value in deionized water. Since experiments were performed with positively charged R6G, interfacial complexation between the dye and the nanoparticles was not observed. The effect of local density variations on mass diffusivity measurements is also addressed. An explanation for the enhancement of mass diffusion is presented using arguments based on dispersion, and it is shown that it correctly describes the order of magnitude differences between the thermal conductivity and mass diffusivity enhancements reported in the literature.

  2. Application of a portable total reflection x-ray fluorescence spectrometer to a trace elemental analysis of wines

    International Nuclear Information System (INIS)

    A portable total reflection X-ray fluorescence (TXRF) spectrometer has been applied to a trace elemental analysis of wines. Sulfur, K, Mn, Fe, and Rb were detected. These five elements were quantified by using 1 ppm of Co as an internal standard. The quantified concentrations ranged from sub-ppm to several hundred ppm. Because of organic substances in wines, the scattering of the incident X-rays from the dry residues of wines becomes strong. Therefore, a high spectral background appears in TXRF spectra of wines. Because of this background, relative standard deviations of the quantified concentrations were from 4 to 28%. Although the high spectral background appeared in the TXRF spectra of the wines, a detection limit down to several tens of ppb was achieved. The present portable spectrometer can be applied to screening for trace elements in wines before an accurate and precise analysis using a large elemental analyzer. (author)

  3. Elemental concentration analysis in the brain of young and old Wistar rats by total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    It is well known that aging is associated with neurobehavioral deficits. The aging process of human brain is characterized by progressive neuronal loss. Furthermore, certain brain areas are more vulnerable to neuronal degeneration than others, reflecting an altered resistance to stress of the tissue itself and/or the lack of adequate immunological defense mechanisms in these regions. About the elemental levels in the brain, it is known that the excess ou deficiency of some elements are toxic for human healthy, being also related to several neurodegenerative diseases. In this way, the main goal of this work was to determine the elemental concentration in the hippocampus of young and old male (n = 10) and female (n = 10) Wistar rats by total reflection X-ray fluorescence spectrometry with synchrotron radiation (SR-TXRF). These measurements were carried out at XRF beam line at Light Synchrotron Brazilian Laboratory, Campinas, Brazil. About the results, we could observe that Al, Fe, Cu, Zn and Br levels were higher in the hippocampus of the old female rats than the young ones. On the other hand, only Cu levels were higher in the hippocampus of the old male rats than the young ones. Therefore, the aging of the hippocampus of the female rats can be characterized by an accumulate for Al, Fe, Cu, Zn and Br. The excess in these elements levels are also associated with several neurodegenerative disorders, such as Alzheimer' disease, Parkinson's disease and Huntington's disease. (author)

  4. Elemental concentration analysis in the brain of young and old Wistar rats by total reflection X-ray fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Serpa, Renata F.B.; Jesus, Edgar F.O. de; Lopes, Ricardo T. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia (COPPE). Nuclear Instrumentation Lab.]. E-mail: renata@lin.ufrj.br; Anjos, Marcelino J. dos [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Physics Inst.]. E-mail: marcelin@lin.ufrj.br; Carmo, Maria G.T. do [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Nutrition Inst.; Rocha, Monica S. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Dept. of Basics and Clinic Pharmacy; Moreira, Silvana [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Civil Engineering Dept.; Martinez, Ana M.B. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Dept. of Histology and Embryology

    2007-07-01

    It is well known that aging is associated with neurobehavioral deficits. The aging process of human brain is characterized by progressive neuronal loss. Furthermore, certain brain areas are more vulnerable to neuronal degeneration than others, reflecting an altered resistance to stress of the tissue itself and/or the lack of adequate immunological defense mechanisms in these regions. About the elemental levels in the brain, it is known that the excess ou deficiency of some elements are toxic for human healthy, being also related to several neurodegenerative diseases. In this way, the main goal of this work was to determine the elemental concentration in the hippocampus of young and old male (n = 10) and female (n = 10) Wistar rats by total reflection X-ray fluorescence spectrometry with synchrotron radiation (SR-TXRF). These measurements were carried out at XRF beam line at Light Synchrotron Brazilian Laboratory, Campinas, Brazil. About the results, we could observe that Al, Fe, Cu, Zn and Br levels were higher in the hippocampus of the old female rats than the young ones. On the other hand, only Cu levels were higher in the hippocampus of the old male rats than the young ones. Therefore, the aging of the hippocampus of the female rats can be characterized by an accumulate for Al, Fe, Cu, Zn and Br. The excess in these elements levels are also associated with several neurodegenerative disorders, such as Alzheimer' disease, Parkinson's disease and Huntington's disease. (author)

  5. Determination of V, Fe, Ni and S in petroleum crude oil by total-reflection x-ray fluorescence

    International Nuclear Information System (INIS)

    The use of total-reflection X-ray fluorescence (TXRF) for the determination of S, V, Fe, and Ni in crude petroleum oil samples is described. The advantages and limitations of the technique for this particular type of analysis are discussed. The method consists of the deposition of milligram or microliter quantities of the sample on a sample holder of a high-quality, optically flat surface made of pure fused SiO2. The sample is irradiated with a collimated, filtered beam of X-rays at a small incident angle so that total reflection takes place at the specimen holder surface. The analysis is carried out on the crude petroleum oils with very little sample treatment. Homogenization is required to improve reproducibility of the measurements. Excitation was achieved with the Lα lines of tungsten X-ray tube operated at 45 kV and at 20 mA. Quantification was carried out using the scattered X-radiation of the exciting L-line of the tungsten tube as internal standard. Detection limits obtained were 20 ppm (= μg g-1) for S, 0.6 ppm for V, 0.1 ppm for Fe and 0.4 ppm for Ni. Reproducibility, expressed as relative standard deviation (RSD), was in the range of 2-6%. Accuracy within the range of 4% was confirmed by the analysis of the standard reference material NIST 1634a and of samples that had been previously analyzed by atomic absorption or neutron activation techniques. Further confirmation of the accuracy of the method was obtained by wavelength dispersive XRF analysis of a range of light and heavy Venezuelan crude oil samples. (author)

  6. Attenuation of global ultraviolet and visible irradiance over Greece during the total solar eclipse of 29 March 2006

    Directory of Open Access Journals (Sweden)

    A. Kazantzidis

    2007-12-01

    Full Text Available The variability of ultraviolet and photosynthetically active radiation (PAR during the total solar eclipse of 29 March 2006 was examined in this study. The measurements from NILU-UV multichannel radiometers at 7 stations of the Greek UV Network were used, where the maximum eclipse percentage ranged from 73.1% to 94.8%. In addition, an extra instrument was established at a remote Greek island, Kastelorizo, which was within the Moon's umbral shadow. The reduction of irradiance at 305 and 312 nm relative to non-eclipse conditions at all sites was almost 1.5 times more than the corresponding decrease in the UVA and visible part of the spectrum and reached 98% for eclipse percentage equal to 94%. The availability of several instruments in close proximity to the path of the umbral shadow provided a challenging test for the models. The measured changes in UV and visible irradiance were compared with 1-D model calculations accounting for the limb darkening effect. The agreement between measurements and modeled values at all sites is within 3% for eclipse percentages of less than 30% and becomes worse as the eclipse progresses. The 1-D model reproduced the spectral effect of the eclipse in UVA and PAR wavelength regions within 3% for eclipse percentages up to 50%, but only the half of the observed change was captured as the eclipse progressed. At three sites, where the eclipse maximum was more than 94%, the measured irradiance at 305 nm for eclipse percentages of more than 85% decreased with slower rates than for longer wavelengths. As a result, the total ozone values, derived from the 305/320 nm ratios, apparently decreased significantly for high eclipse percentages. The effect is similar at all three sites, but the interpretation of this observation remains a challenge. Comparison results with 3-D model calculations shortly before, during and shortly after totality were performed for the first time and revealed an agreement with measurements

  7. Worldwide distribution of Total Reflection X-ray Fluorescence instrumentation and its different fields of application: A survey

    International Nuclear Information System (INIS)

    A survey was carried out with users and manufacturers of Total Reflection X-ray Fluorescence instrumentation in order to demonstrate the worldwide distribution of TXRF equipment and the different fields of applications. In general, TXRF users come from universities and scientific institutes, from working places at synchrotron beam-lines, or laboratories in semiconductor fabs. TXRF instrumentation is distributed in more than 50 countries on six continents and is applied at about 200 institutes and laboratories. The number of running desktop instruments amounts to nearly 300 units. About 60 beamlines run working places dedicated to TXRF. About 300 floor-mounted instruments are estimated to be used in about 150 fabs of the semiconductor industry. In total, 13 different fields of applications could be registered statistically from three different aspects. - Highlights: • According to the survey world maps show the distribution of TXRF equipment. • Nearly 700 individual units are running actually in 57 countries of 6 continents. • Users work at 200 universities, 60 synchrotron-beamlines, and 150 semiconductor fabs. • 13 fields of applications (e.g. environmental, chemical) are evaluated statistically. • Manufacturers, conference members and authors lead to 3 different pie-charts

  8. Structure, characteristics and potential of commercial equipment Total Reflection X Ray Fluorescence for multielemental chemical analysis: Current State

    International Nuclear Information System (INIS)

    The method Total Reflection X-Ray Fluorescence for chemical multielemental analysis has evolved in the last years with the availability of commercial systems for applications in the field of electronics and chemical multielemental analysis in samples of mineral and biological origin. The basic components of these equipment cam be summarized in a system of excitement, a geometric arrangement (optics) for collimate and monochromatize the primary radiation, a X-rays detector, and the electronic si stem for spectral data acquisition including the software for spectra unfolding, qualitative and quantitative analysis, and the complete instrument operation. Additionally the makers offer the conventional 45 degrees geometry for the excitement solid and liquid samples of bigger volume in direct form. The available bibliographical and commercial information to the moment of preparing this lecture, basically reports the following types of components for the X-rays spectrometers in geometry of total reflection chemical multielemental analysis (they are excluded those RTFX equipment dedicated to the electronic industry for quality control of Si wafers purity used for the production of circuits (chips). Excitation: X-rays tube of high vacuum with power among 1300 to 2000 watts and different types of anode; X-rays ceramic metal tube, with power up to 40 watts, and anode of molybdenum, tug steno, etc. Detection: detector semiconductor of silicon-lithium cooled with liquid nitrogen; detector of solid state silicon cooled electrically (Si-PI N diode or detector of diffused silicon Sdd). Optics: multi stratum monochromator; multi stratum Ni-C monochromator; double multi stratum monochromator. Electronic: spectroscopical amplifier espectroscopico and ana logical digital convertor adapted to a personal computer IBM compatible, with software for qualitative and quantitative analysis of samples by means of Windows, and for the complete operation of the analyzer from the Pc. In this work

  9. Clonorchis sinensis-derived total protein attenuates airway inflammation in murine asthma model by inducing regulatory T cells and modulating dendritic cell functions

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Young-Il [Div. of Malaria and Parasitic Diseases, Korea Centers for Disease Control and Prevention, Osong (Korea, Republic of); Kim, Seung Hyun [Div. of AIDS, National Institute of Health, Korea Centers for Disease Control and Prevention, Osong (Korea, Republic of); Ju, Jung Won; Cho, Shin Hyeong; Lee, Won Ja [Div. of Malaria and Parasitic Diseases, Korea Centers for Disease Control and Prevention, Osong (Korea, Republic of); Park, Jin Wook; Park, Yeong-Min [Dept. of Microbiology and Immunology, College of Medicine, Pusan National University, Yang-San (Korea, Republic of); Lee, Sang Eun, E-mail: ondalgl@cdc.go.kr [Div. of Malaria and Parasitic Diseases, Korea Centers for Disease Control and Prevention, Osong (Korea, Republic of)

    2011-04-22

    Highlights: {yields} Treatment with Clonorchis sinensis-derived total protein attenuates OVA-induced airway inflammation and AHR to methacholine. {yields} Induction of CD4{sup +}CD25{sup +}Foxp3{sup +} T cells and IL-10 along with suppression of splenocyte proliferation by C. sinensis-derived total protein. {yields} C. sinensis-derived total protein interferes with the expression of co-stimulatory molecules in DCs. -- Abstract: Asthma is characterized by Th2-mediated inflammation, resulting in airway hyperresponsiveness (AHR) through airway remodeling. Recent epidemiological and experimental reports have suggested an inverse relationship between the development of allergy and helminth infections. Infection by Clonorchis sinensis, a liver fluke that resides in the bile duct of humans, is endemic predominantly in Asia including Korea and China. Using a murine model for asthma, we investigated the effects of C. sinensis-derived total protein (Cs-TP) on allergen-induced airway inflammation and the mechanism underlying the protective effects of Cs-TP administration on asthma. Treatment with Cs-TP attenuated OVA-induced airway inflammation and methacholine-induced AHR, as well as eosinophilia development, lymphocyte infiltration into the lung, and goblet cell metaplasia. This protective effect of Cs-TP is associated with markedly reduced OVA-specific IgE and Th1/Th2 cytokine production. Moreover, Cs-TP increased the number of CD4{sup +}CD25{sup +}Foxp3{sup +} regulatory T (Treg) cells as well as their suppressive activity. In fact, proliferation of OVA-restimulated splenocytes was suppressed significantly. Cs-TP also inhibited the expression of such co-stimulatory molecules as CD80, CD86, and CD40 in LPS- or OVA-stimulated dendritic cells (DCs), suggesting that Cs-TP could interfere with the capacity of airway DCs to prime naive T cells. These data demonstrate the capacity of C. sinensis to ameliorate allergic asthma and broaden our understanding of the paradoxical

  10. Hydrochemistry study of Ambohimangakely and Ambohimanambola phreatic aquifers using total reflection X-ray fluorescence and ion chromatography analysis methods

    International Nuclear Information System (INIS)

    Nowadays, the human being activities are increasing and enlarging quickly in different domains. These activities can affect the water quality, which is the basis of all living creature. Regular and continuous studies on water quality are therefore necessary so that potable water is available for use. In the framework of the present study, Ambohimangakely and of Ambohimanambola phreatic aquifers are investigated. The objectives of the research work are the determination of the water quality and the mechanism responsible for this quality. Ground water sample were collected to better understand the mechanism that controls the chemical composition of the surficial aquifers. Total Reflection X-ray Fluorescence and Ion chromatography were used for trace elements and major ions analyses, respectively. The principal component analysis (PCA), the Scholler-Berkaloff diagram and the Piper diagram were used for hydrochemical studies. The results showed (1) ground waters are characterized by eight chemical facies : Na-(Ca, Mg)-HCO3, Na-HCO3, Ca-Cl, Ca-HCO3, Mg-HCO3, Mg-Na-Cl-HCO3, Na-Cl-NO3 et Na-NO3-Cl. (2) ground waters composition would be of two different origins, namely water-rock interaction and anthropogenic

  11. Determination of arsenic in water samples by Total Reflection X-Ray Fluorescence using pre-concentration with alumina

    International Nuclear Information System (INIS)

    The determination of arsenic in water samples requires techniques of high sensitivity. Total Reflection X-Ray Fluorescence (TXRF) allows the determination but a prior separation and pre-concentration procedure is necessary. Alumina is a suitable substrate for the selective separation of the analytes. A method for separation and pre-concentration in alumina, followed by direct analysis of the alumina is evaluated. Quantification was performed using the Al-Kα and Co-Kα lines as internal standard in samples prepared on an alumina matrix, and compared to a calibration with aqueous standards. Artificial water samples of As (III) and As (V) were analyzed after the treatment. Fifty milliliters of the sample at ppb concentration levels were mixed with 10 mg of alumina. The pH, time and temperature were controlled. The alumina was separated from the slurry by centrifugation, washed with de-ionized water and analyzed directly on the sample holder. A pre-concentration factor of 100 was found, with detection limit of 0.7 μgL-1. The percentage of recovery was 98% for As (III) and 95% for As (V) demonstrating the suitability of the procedure.

  12. Multielemental analysis of human amniotic fluid by use of Total Reflection X-Ray Fluorescence and Rutherford Forward Scattering

    International Nuclear Information System (INIS)

    Full text: Correlation studies between the concentrations of certain elements present in human amniotic fluid (A F) and fetal disorders are important. There is a need for a technique or a group of complementary techniques for the reliable elemental analysis of A F. In order to study the reliability of Total Reflection X-Ray Fluorescence (TXRF), a comparison between TXRF and the well established technique of Proton Induced X-Ray Emission (PIXE) has been carried out by measuring the concentrations of Cl, K, Ca, Fe, Cu, Zn and Br in 10 common samples of A F. Different degrees of consistency have been obtained depending on the element being analyzed. There is a need to establish the experimental conditions under which a complete agreement between TXRF and PIXE is achieved. A common weakness of TXRF and PIXE is the difficulty to obtain adequate signals from elements lighter than Aluminum. To overcome this problem, a method based on Rutherford Forward Scattering (RFS) for the quantification of elements as light as Lithium is under development. Details on the experimental configuration (beam type, beam energy, detector angle, sample preparation, etc) that leads to an appropriate mass separation by using RFS will be given. Both TXRF and RFS are extremely convenient for correlating physical and medical data because they are non-destructive multielemental techniques which require small amounts of the sample to be analyzed

  13. Determination of platinum group metal catalyst residues in active pharmaceutical ingredients by means of total reflection X-ray spectrometry

    Science.gov (United States)

    Marguí, Eva; Queralt, Ignasi; Hidalgo, Manuela

    2013-08-01

    The control of metal catalyst residues (i.e., platinum group metals (PGMs)) in different stages of the manufacturing processes of the active pharmaceutical ingredients (APIs) and, especially, in the final product is crucial. For API specimens, there are strict guidelines to limit the levels of metal residues based on their individual levels of safety concern. For PGMs the concentration limit has been established at 10 mg/kg in the API. Therefore great effort is currently being devoted to the development of new and simple procedures to control metals in pharmaceuticals. In the present work, an analytical methodology based on benchtop total reflection X-ray fluorescence spectrometry (TXRF) has been developed for the rapid and simple determination of some PGM catalyst impurities (Rh, Pd, Ir and Pt) in different types of API samples. An evaluation of different sample treatments (dissolution and digestion of the solid pharmaceutical samples) has been carried out and the developed methodologies have been validated according to the analytical parameters to be considered and acceptance criteria for PGM determination according to the United States Pharmacopeia (USP). Limits of quantification obtained for PGM metals were in the range of 2-4 mg/kg which are satisfactory according to current legislation. From the obtained results it is shown that the developed TXRF method can be implemented in the pharmaceutical industries to increase productivity of the laboratory; offering an interesting and complementary analytical tool to other atomic spectroscopic methods.

  14. Determination of trace element distribution in cancerous and normal human tissues by total reflection X-ray fluorescence analysis

    Science.gov (United States)

    von Czarnowski, D.; Denkhaus, E.; Lemke, K.

    1997-07-01

    The intention of this study was to establish a method for cancer diagnosis. For this purpose, different trace element distributions in carcinomas of the digestive tract and in normal tissues of human stomach, colon and rectum in correlation to the type of cancer were determined by total reflection X-ray fluorescence analysis (TXRF). The tissue samples were frozen and cut by a microtome into 10 μm sections, and a modified sample excision technique was introduced according to the aim of this research. After drying and spiking of the tissue sections, more than 20 elements, especially biologically relevant ones, were determined. The repeatabilities of measurements of element concentrations in malignant and normal tissues were calculated to be 10-30% (RSD) depending on the specific element. The concentration of Ca was found to be virtually constant (0.250±0.025 μg per 0.1 mm 3) in normal tissue and in carcinoma of the digestive organs. A significant diminution of Cr, Fe and Ni in carcinoma of the stomach, of Cr and Co in carcinoma of the colon and a significant accumulation of K in cancerous tissue of the colon and of Fe and K in neoplastic tissue of the rectum were discovered for a very limited population of patients.

  15. Inorganic pigment study of the San Pedro Gonzalez Telmo Sibyls using total reflection X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez, Cristina, E-mail: vazquez@cnea.gov.a [Universidad de Buenos Aires, Facultad de Ingenieria, Paseo Colon 850. C1063ACU, Buenos Aires (Argentina); Comision Nacional de Energia Atomica, Gerencia Quimica, Av. Gral Paz 1499, B1650KNA, San Martin (Argentina); Custo, Graciela, E-mail: custo@cnea.gov.a [Comision Nacional de Energia Atomica, Gerencia Quimica, Av. Gral Paz 1499, B1650KNA, San Martin (Argentina); Barrio, Nestor, E-mail: nbarrio@unsam.edu.a [CEIRCAB-TAREA, Universidad Nacional de San Martin (UNSAM), Escuela de Humanidades, Campus Miguelete, 25 de Mayo y Francia, B1650KNA, San Martin (Argentina); Burucua, Jose, E-mail: gburucua@unsam.edu.a [CEIRCAB-TAREA, Universidad Nacional de San Martin (UNSAM), Escuela de Humanidades, Campus Miguelete, 25 de Mayo y Francia, B1650KNA, San Martin (Argentina); Boeykens, Susana [Universidad de Buenos Aires, Facultad de Ingenieria, Paseo Colon 850. C1063ACU, Buenos Aires (Argentina); Marte, Fernando, E-mail: fmarte@unsam.edu.a [CEIRCAB-TAREA, Universidad Nacional de San Martin (UNSAM), Escuela de Humanidades, Campus Miguelete, 25 de Mayo y Francia, B1650KNA, San Martin (Argentina)

    2010-09-15

    This article describes the study carried out on a series of oil paintings on canvas from the eighteenth century that were restored at Centro de Produccion e Investigacion en Restauracion y Conservacion Artistica y Bibliografica - Tarea (CEIRCAB-Tarea), Buenos Aires, Argentina: the San Pedro Gonzalez Telmo Sibyls. Experimental study was undertaken to identify inorganic pigments and the technique used in their confection; and, in this way, try to add information about their local origin. Therefore special emphasis was put to infer technologies used in the manufacturing of these paintings. Elemental analysis was performed by total reflection X-ray fluorescence spectrometry (TXRF) and complemented by optical and polarized light microscopy. Microsampling was carefully done over areas of the paintings which were damaged and where a small additional loss will not be noticed. This investigation has shown that a variety of pigments were used, namely earth pigments (red and yellow ochres), white lead, vermilion, etc., and they were used either pure or in mixtures. This characterization helped conservators in their decisions regarding a better understanding of the deterioration processes. In addition, this research about the material composition allowed the art historians and restorers the possibility to obtain information about where, when or by whom The San Pedro Gonzalez Telmo Sibyls may have been painted.

  16. Vapor phase treatment–total reflection X-ray fluorescence for trace elemental analysis of silicon wafer surface

    International Nuclear Information System (INIS)

    Vapor phase treatment (VPT) was under investigation by the International Organization for Standardization/Technical Committee 201/Working Group 2 (ISO/TC201/WG2) to improve the detection limit of total reflection X-ray fluorescence spectroscopy (TXRF) for trace metal analysis of silicon wafers. Round robin test results have confirmed that TXRF intensity increased by VPT for intentional contamination with 5 × 109 and 5 × 1010 atoms/cm2 Fe and Ni. The magnification of intensity enhancement varied greatly (1.2–4.7 in VPT factor) among the participating laboratories, though reproducible results could be obtained for average of mapping measurement. SEM observation results showed that various features, sizes, and surface densities of particles formed on the wafer after VPT. The particle morphology seems to have some impact on the VPT efficiency. High resolution SEM observation revealed that a certain number of dots with SiO2, silicate and/or carbon gathered to form a particle and heavy metals, Ni and Fe in this study were segregated on it. The amount and shape of the residue should be important to control VPT factor. - Highlights: • This paper presents a summary of study results of VPT–TXRF using ISO/TC201/WG2. • Our goal is to analyze the trace metallic contamination on silicon wafer with concentrations below 1 × 1010 atoms/cm2. • The efficiency and mechanism of VPT are discussed under several round robin tests and systematic studies

  17. Assessment of serum selenium levels in 2-month-old sucking calves using total reflection X-ray fluorescence technique

    Science.gov (United States)

    Buoso, M. C.; Ceccato, D.; Moschini, G.; Bernardini, D.; Testoni, S.; Torboli, A.; Valdes, M.

    2001-11-01

    The assessment of selenium status of livestock plays an important role in the production of medicine since low serum Se levels influence disease resistance in ruminants. It has been proved that Se deficiency may cause muscular dystrophy, cardiomyopathy and even death. Serum level has been widely used to evaluate the Se short-term status in animals since there is a good association between serum Se level and the dietary intake of the element over a wide range. The purpose of this work was to determine the Se serum concentration in a population of 78 sucking 2-month-old calves, in order to corroborate a clinical diagnosis of severe deficiency status. The samples were analyzed by total reflection X-ray fluorescence (TXRF) at the ITAL STRUCTURES Research Laboratory. The results obtained from the serum samples presented Se concentrations varying from 10 to 66 ng/ml. The comparison between the obtained values and the expected serum selenium values (60-80 ng/ml), confirmed a mild to severe deficiency status in the investigated population.

  18. Pharmacokinetic detection of penicillin excreted in urine using a totally internally reflected resonance light scattering technique with cetyltrimethylammonium bromide.

    Science.gov (United States)

    Huang, Cheng Zhi; Feng, Ping; Li, Yuan Fang; Tan, Ke Jun

    2005-05-01

    A quantitative analysis method for penicillins including ampicillin (AmP), benzyl penicillin (BP), oxacillin (OA) and amoxycillin (AmO) is proposed that makes use of the totally internally reflected resonance light scattering (TIR-RLS) signal from the penicillin at the H2O/CCl4 interface in the presence of cetyltrimethylammonium bromide (CTMAB), and enables the pharmacokinetics of penicillin taken orally and excreted through urine to be monitored. Penicillin is coadsorbed with CTMAB at the H2O/CCl4 interface in neutral solution, resulting in the formation of ion associates that display greatly enhanced TIR-RLS signals (maximum at 368-372 nm). This enhanced TIR-RLS intensity was found to be proportional to the penicillin concentration over the range 0.2 x 10(-6) to 2.2 x 10(-6) mol L(-1), with limits of determination (3sigma) of 5.0 x 10(-8) to 7.0 x 10(-8) mol L(-1). Pharmacokinetics studies performed using the present method show that the excretion of orally-taken ampicillin through urine has a half-time of 1.05 h and an excremental quantum over 8 h of 49.3%, respectively. PMID:15900456

  19. Characterization of GLUT4-containing vesicles in 3T3-L1 adipocytes by total internal reflection fluorescence microscopy

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Insulin-responsive GLUT4(glucose transporter 4) translocation plays a major role in regulating glucose uptake in adipose tissue and muscle.Whether or not there is a specialized secretory GSV(GLUT4 storage vesicle) pool,and more importantly how GSVs are translocated to the PM(plasma membrane) under insulin stimulation is still under debate.In the present study,we systematically analyzed the dynamics of a large number of single GLUT4-containing vesicles in 3T3-L1 adipocytes by TIRFM(total internal reflection fluorescence microscopy).We found that GLUT4-containing vesicles can be classified into three groups according to their mobility,namely vertical,stable,and lateral GLUT4-containing vesicles.Among these groups,vertical GLUT4-containing vesicles exclude transferrin receptors and move towards the PM specifically in response to insulin stimulation,while stable and lateral GLUT4-containing vesicles contain transferrin receptors and show no insulin responsiveness.These data demonstrate that vertical GLUT4-containing vesicles correspond to specialized secretory GSVs,which approach the PM directly and bypass the constitutive recycling pathway.

  20. Intelligent Simultaneous Quantitative Online Analysis of Environmental Trace Heavy Metals with Total-Reflection X-Ray Fluorescence

    Directory of Open Access Journals (Sweden)

    Junjie Ma

    2015-05-01

    Full Text Available Total-reflection X-ray fluorescence (TXRF has achieved remarkable success with the advantages of simultaneous multi-element analysis capability, decreased background noise, no matrix effects, wide dynamic range, ease of operation, and potential of trace analysis. Simultaneous quantitative online analysis of trace heavy metals is urgently required by dynamic environmental monitoring and management, and TXRF has potential in this application domain. However, it calls for an online analysis scheme based on TXRF as well as a robust and rapid quantification method, which have not been well explored yet. Besides, spectral overlapping and background effects may lead to loss of accuracy or even faulty results during practical quantitative TXRF analysis. This paper proposes an intelligent, multi-element quantification method according to the established online TXRF analysis platform. In the intelligent quantification method, collected characteristic curves of all existing elements and a pre-estimated background curve in the whole spectrum scope are used to approximate the measured spectrum. A novel hybrid algorithm, PSO-RBFN-SA, is designed to solve the curve-fitting problem, with offline global optimization and fast online computing. Experimental results verify that simultaneous quantification of trace heavy metals, including Cr, Mn, Fe, Co, Ni, Cu and Zn, is realized on the online TXRF analysis platform, and both high measurement precision and computational efficiency are obtained.

  1. Inorganic pigment study of the San Pedro Gonzalez Telmo Sibyls using total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    This article describes the study carried out on a series of oil paintings on canvas from the eighteenth century that were restored at Centro de Produccion e Investigacion en Restauracion y Conservacion Artistica y Bibliografica - Tarea (CEIRCAB-Tarea), Buenos Aires, Argentina: the San Pedro Gonzalez Telmo Sibyls. Experimental study was undertaken to identify inorganic pigments and the technique used in their confection; and, in this way, try to add information about their local origin. Therefore special emphasis was put to infer technologies used in the manufacturing of these paintings. Elemental analysis was performed by total reflection X-ray fluorescence spectrometry (TXRF) and complemented by optical and polarized light microscopy. Microsampling was carefully done over areas of the paintings which were damaged and where a small additional loss will not be noticed. This investigation has shown that a variety of pigments were used, namely earth pigments (red and yellow ochres), white lead, vermilion, etc., and they were used either pure or in mixtures. This characterization helped conservators in their decisions regarding a better understanding of the deterioration processes. In addition, this research about the material composition allowed the art historians and restorers the possibility to obtain information about where, when or by whom The San Pedro Gonzalez Telmo Sibyls may have been painted.

  2. Depth profiling using total reflection X-ray fluorescence spectrometry alone and in combination with ion beam sputtering

    Science.gov (United States)

    Schwenke, H.; Knoth, J.; Günther, R.; Wiener, G.; Bormann, R.

    1997-07-01

    The capability of total reflection X-ray fluorescence spectrometry (TXRF) for depth profiling is examined by means of selected examples including organometallic layers, an implantation profile of arsenic in silicon and a layered nickel/cobalt structure. For structures without density differences that are deeper than 20 nm or so, and also for buried layers and for the examination of sharp interfaces, which require the highest resolution, two different combinations of ion beam sputtering with TXRF have been employed. A microsectioning technique was investigated in which samples were etched to a bevel shape and subsequently scanned by TXRF. A depth resolution of 2.5 nm was obtained. Alternatively, the so called "transfer technique" was investigated. This involves surface atoms being sputtered by an ion beam and immediately deposited on a silicon wafer rotated behind a slit which is moved in step with the sputter progress. Subsequently, the wafer is scanned by TXRF. Using this technique, the width of a coherent Ti/Al interface within a layered structure was measured to be 1.4 nm. The depth resolutions of the "microsectioning" and the "transfer" techniques are compared with data from RBS, XPS, SIMS and SNMS.

  3. Element determination in natural biofilms of mine drainage water by total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Human impacts like mining activities lead to higher element concentration in surface waters. For different pollution levels, the consequences for aquatic organisms are not yet investigated in detail. Therefore, the aim of this investigation is to determine the influence of mining affected surface waters on biofilms. Elements like heavy metals can be absorbed on cell walls and on polymeric substances or enter the cytoplasm of the cells. Thus, they are important for the optimization of industrial biotechnological processes and the environmental biotechnology. Beyond this, biofilms can also play an important role in wastewater treatment processes and serve as bioindicators in the aquatic environment. The presented total reflection X-ray fluorescence spectroscopic investigation was performed to compare the element accumulation behavior of biofilms grown on natural or on artificial materials of drainage water affected by former copper mining activities. A high salt and heavy metal pollution is characteristic for the drainage water. For an assessment of these results, samples from stream Schlenze upstream the confluence with the drainage water, a small tributary of the Saale River in central Germany, were analyzed, too

  4. Element determination in natural biofilms of mine drainage water by total reflection X-ray fluorescence spectrometry

    Science.gov (United States)

    Mages, Margarete; von Tümpling, Wolf; van der Veen, Andrea; Baborowski, Martina

    2006-11-01

    Human impacts like mining activities lead to higher element concentration in surface waters. For different pollution levels, the consequences for aquatic organisms are not yet investigated in detail. Therefore, the aim of this investigation is to determine the influence of mining affected surface waters on biofilms. Elements like heavy metals can be absorbed on cell walls and on polymeric substances or enter the cytoplasm of the cells. Thus, they are important for the optimization of industrial biotechnological processes and the environmental biotechnology. Beyond this, biofilms can also play an important role in wastewater treatment processes and serve as bioindicators in the aquatic environment. The presented total reflection X-ray fluorescence spectroscopic investigation was performed to compare the element accumulation behavior of biofilms grown on natural or on artificial materials of drainage water affected by former copper mining activities. A high salt and heavy metal pollution is characteristic for the drainage water. For an assessment of these results, samples from stream Schlenze upstream the confluence with the drainage water, a small tributary of the Saale River in central Germany, were analyzed, too.

  5. Total reflection X-ray fluorescence applied to the chemical elements analysis of the mate tea infusion (Ilex-paraguariensis)

    International Nuclear Information System (INIS)

    The purpose was to evaluate simultaneously the chemical element concentrations from K to Sr (19≤Z≤38) range in six samples of mate tea (Ilex paraguariensis) infusion, commercially available in Paraguay and South of Brazil. The chemical analysis of this beverage has a great nutritional importance for the native people of these areas, due to their large daily consumption. For the determination of these elements the dry-ashing and total reflection X-rays fluorescence (TXRF) were used. The methodology showed limits of detection among 81 ng.mL-1 for K to 10 ng.mL-1 for Zn. Six infusion samples were prepared in triplicate, and the concentration was 3,8 to 10,2 μg.mL-1 for K, Ca and Mn, 0,21 to 1,07 μg. mL-1 for Fe and Zn and 0.03 to 0,17 μg.mL-1 for Ni, Cu, Br, Rb and Sr. The Mn and Ni concentrations are above the maximum permissible values for drinking water established by World Health Organization and Brazilian legislation (these organisms do not regulate the maximum permissible values for chemical elements in mate tea infusion). (author)

  6. Determination of arsenic in water samples by Total Reflection X-Ray Fluorescence using pre-concentration with alumina

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Haydn [Laboratorio de Fisica Nuclear, Dpto. De Fisica, Universidad Simon Bolivar, Sartenejas, Baruta (Venezuela, Bolivarian Republic of); Marco Parra, Lue-Meru, E-mail: luemerumarco@yahoo.e [Universidad Centroccidental Lisandro Alvarado, Dpto. Quimica y Suelos, Decanato de Agronomia, Tarabana, Cabudare, Edo.Lara (Venezuela, Bolivarian Republic of); Bennun, Leonardo [Universidad de Concepcion, Concepcion (Chile); Greaves, Eduardo D. [Laboratorio de Fisica Nuclear, Dpto. De Fisica, Universidad Simon Bolivar, Sartenejas, Baruta (Venezuela, Bolivarian Republic of)

    2010-06-15

    The determination of arsenic in water samples requires techniques of high sensitivity. Total Reflection X-Ray Fluorescence (TXRF) allows the determination but a prior separation and pre-concentration procedure is necessary. Alumina is a suitable substrate for the selective separation of the analytes. A method for separation and pre-concentration in alumina, followed by direct analysis of the alumina is evaluated. Quantification was performed using the Al-K{alpha} and Co-K{alpha} lines as internal standard in samples prepared on an alumina matrix, and compared to a calibration with aqueous standards. Artificial water samples of As (III) and As (V) were analyzed after the treatment. Fifty milliliters of the sample at ppb concentration levels were mixed with 10 mg of alumina. The pH, time and temperature were controlled. The alumina was separated from the slurry by centrifugation, washed with de-ionized water and analyzed directly on the sample holder. A pre-concentration factor of 100 was found, with detection limit of 0.7 {mu}gL{sup -1}. The percentage of recovery was 98% for As (III) and 95% for As (V) demonstrating the suitability of the procedure.

  7. Analytical performance of benchtop total reflection X-ray fluorescence instrumentation for multielemental analysis of wine samples

    Science.gov (United States)

    Dalipi, Rogerta; Marguí, Eva; Borgese, Laura; Bilo, Fabjola; Depero, Laura E.

    2016-06-01

    Recent technological improvements have led to a widespread adoption of benchtop total reflection X-ray fluorescence systems (TXRF) for analysis of liquid samples. However, benchtop TXRF systems usually present limited sensitivity compared with high-scale instrumentation which can restrict its application in some fields. The aim of the present work was to evaluate and compare the analytical capabilities of two TXRF systems, equipped with low power Mo and W target X-ray tubes, for multielemental analysis of wine samples. Using the Mo-TXRF system, the detection limits for most elements were one order of magnitude lower than those attained using the W-TXRF system. For the detection of high Z elements like Cd and Ag, however, W-TXRF remains a very good option due to the possibility of K-Lines detection. Accuracy and precision of the obtained results have been evaluated analyzing spiked real wine samples and comparing the TXRF results with those obtained by inductively coupled plasma emission spectroscopy (ICP-OES). In general, good agreement was obtained between ICP-OES and TXRF results for the analysis of both red and white wine samples except for light elements (i.e., K) which TXRF concentrations were underestimated. However, a further achievement of analytical quality of TXRF results can be achieved if wine analysis is performed after dilution of the sample with de-ionized water.

  8. Herschel PEP/HerMES: the redshift evolution (0 ≤ z ≤ 4) of dust attenuation and of the total (UV+IR) star formation rate density

    Science.gov (United States)

    Burgarella, D.; Buat, V.; Gruppioni, C.; Cucciati, O.; Heinis, S.; Berta, S.; Béthermin, M.; Bock, J.; Cooray, A.; Dunlop, J. S.; Farrah, D.; Franceschini, A.; Le Floc'h, E.; Lutz, D.; Magnelli, B.; Nordon, R.; Oliver, S. J.; Page, M. J.; Popesso, P.; Pozzi, F.; Riguccini, L.; Vaccari, M.; Viero, M.

    2013-06-01

    Using new homogeneous luminosity functions (LFs) in the far-ultraviolet (FUV) from VVDS and in the far-infrared (FIR) from Herschel/PEP and Herschel/HerMES, we studied the evolution of the dust attenuation with redshift. With this information, we were able to estimate the redshift evolution of the total (FUV + FIR) star formation rate density (SFRDTOT). By integrating SFRDTOT, we followed the mass building and analyzed the redshift evolution of the stellar mass density (SMD). This article aims at providing a complete view of star formation from the local Universe to z ~ 4 and, using assumptions on earlier star formation history, compares this evolution with previously published data in an attempt to draw a homogeneous picture of the global evolution of star formation in galaxies. Our main conclusions are that: 1) the dust attenuation AFUV is found to increase from z = 0 to z ~ 1.2 and then starts to decrease until our last data point at z = 3.6; 2) the estimated SFRD confirms published results to z ~ 2. At z > 2, we observe either a plateau or a small increase up to z ~ 3 and then a likely decrease up to z = 3.6; 3) the peak of AFUV is delayed with respect to the plateau of SFRDTOT and a probable origin might be found in the evolution of the bright ends of the FUV and FIR LFs; 4) using assumptions (exponential rise and linear rise with time) for the evolution of the star formation density from z = 3.6 to zform = 10, we integrated SFRDTOT and obtained a good agreement with the published SMDs. Herschel is an ESA space observatory with science instruments provided by European-led Principal Investigator consortia and with important participation from NASA.

  9. Total reflection X-ray fluorescence analysis of oral fluids of women affected by osteoporosis and osteopenia

    International Nuclear Information System (INIS)

    Osteoporosis is a disease characterized by low bone mass and microarchitectural deterioration of bone tissue, leading to bone fragility and an increased susceptibility to fractures; the early stage of decreased bone density is called osteopenia. More than 200 million people are affected and about 50% of post-menopausic women are expected to develop the disease. Osteoporosis, osteopenia and periodontal disease have in common several risk factors, being hyperthyroidism and smoking habits the most important ones. There is scarce information in the literature about the association between periodontal disease and osteoporosis and/or osteopenia. Some works suggest that osteoporotic women are susceptible to a higher loss of periodontal insertion, alveolar bones, and teeth. Thirty adult post-menopausic women were studied; some of them were healthy (control group) and the rest of them were undergoing some stage of osteoporosis or osteopenia. All the subjects were healthy, non-smokers, not having dental implants, and with communitarian periodontal index higher than 1(CPI > 1). Samples of saliva and gingival crevice fluid were extracted with calibrated micro-capillaries and deposited on Si reflectors. Known amounts of Ga were added to the samples in order to act as internal standard for quantification by the total reflection x-ray fluorescence technique. Experimental concentrations of several elements (P, S, Cl, K, Ca, Cr, Fe, NI, Cu, and Zn) were determined. The concentration of some elements in saliva showed different behavior as compared to gingival crevice fluid. Some critical elements of bone composition, such as Ca and Zn, present very distinguishable behavior. Improvements in the statistics are required for a better assessment of a routine method and to establish some correlation with periodontal disease. TXRF seems to be a promising method to evaluate the evolution of osteoporosis

  10. Determination of platinum group metal catalyst residues in active pharmaceutical ingredients by means of total reflection X-ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Marguí, Eva, E-mail: eva.margui@udg.edu [Department of Chemistry, University of Girona, Campus Montilivi, 17071 Girona (Spain); Queralt, Ignasi, E-mail: iqueralt@ictja.csic.es [Laboratory of X-ray Analytical Applications, Institute of Earth Sciences “Jaume Almera”, CSIC, Solé Sabarís s/n, 08028 Barcelona (Spain); Hidalgo, Manuela, E-mail: manuela.hidalgo@udg.edu [Department of Chemistry, University of Girona, Campus Montilivi, 17071 Girona (Spain)

    2013-08-01

    The control of metal catalyst residues (i.e., platinum group metals (PGMs)) in different stages of the manufacturing processes of the active pharmaceutical ingredients (APIs) and, especially, in the final product is crucial. For API specimens, there are strict guidelines to limit the levels of metal residues based on their individual levels of safety concern. For PGMs the concentration limit has been established at 10 mg/kg in the API. Therefore great effort is currently being devoted to the development of new and simple procedures to control metals in pharmaceuticals. In the present work, an analytical methodology based on benchtop total reflection X-ray fluorescence spectrometry (TXRF) has been developed for the rapid and simple determination of some PGM catalyst impurities (Rh, Pd, Ir and Pt) in different types of API samples. An evaluation of different sample treatments (dissolution and digestion of the solid pharmaceutical samples) has been carried out and the developed methodologies have been validated according to the analytical parameters to be considered and acceptance criteria for PGM determination according to the United States Pharmacopeia (USP). Limits of quantification obtained for PGM metals were in the range of 2–4 mg/kg which are satisfactory according to current legislation. From the obtained results it is shown that the developed TXRF method can be implemented in the pharmaceutical industries to increase productivity of the laboratory; offering an interesting and complementary analytical tool to other atomic spectroscopic methods. - Highlights: • A TXRF method for PGM catalyst residue determination in API samples is presented. • Analysis can be performed using 10 μL of the internal standardized dissolved API. • The method is rapid, simple and suitable according to the USP requirements.

  11. Vapor phase treatment–total reflection X-ray fluorescence for trace elemental analysis of silicon wafer surface

    Energy Technology Data Exchange (ETDEWEB)

    Takahara, Hikari, E-mail: hikari@rigaku.co.jp [Rigaku Corp., 14-8 Akaoji-cho, Takatsuki, Osaka 569-1146 (Japan); Mori, Yoshihiro [Horiba Ltd., 2 Miyanohigashi, Kisshoin, Minami-ku, Kyoto 601-8510 (Japan); Shibata, Harumi [SUMCO Corporation, Seavance North, 1-2-1 Shibaura, Minato-ku, Tokyo 105-8634 (Japan); Shimazaki, Ayako [Toshiba Corporation, 8, Shinsugita-cho, Isogo-ku, Yokohama 235-8522 (Japan); Shabani, Mohammad B. [Mitsubishi Material Corporation, 1-297, Kitabukuro-cho, Omiya-ku, Saitama 330-8508 (Japan); Yamagami, Motoyuki [Rigaku Corp., 14-8 Akaoji-cho, Takatsuki, Osaka 569-1146 (Japan); Yabumoto, Norikuni [Analysis Atelier Co., 4-36-4, Yoyogi, Shibuya-ku, Tokyo 151-0053 (Japan); Nishihagi, Kazuo [Horiba Ltd., 2 Miyanohigashi, Kisshoin, Minami-ku, Kyoto 601-8510 (Japan); Gohshi, Yohichi [Tsukuba University, 1-1-1, Tennodai, Tsukuba, Ibaraki 305-8571 (Japan)

    2013-12-01

    Vapor phase treatment (VPT) was under investigation by the International Organization for Standardization/Technical Committee 201/Working Group 2 (ISO/TC201/WG2) to improve the detection limit of total reflection X-ray fluorescence spectroscopy (TXRF) for trace metal analysis of silicon wafers. Round robin test results have confirmed that TXRF intensity increased by VPT for intentional contamination with 5 × 10{sup 9} and 5 × 10{sup 10} atoms/cm{sup 2} Fe and Ni. The magnification of intensity enhancement varied greatly (1.2–4.7 in VPT factor) among the participating laboratories, though reproducible results could be obtained for average of mapping measurement. SEM observation results showed that various features, sizes, and surface densities of particles formed on the wafer after VPT. The particle morphology seems to have some impact on the VPT efficiency. High resolution SEM observation revealed that a certain number of dots with SiO{sub 2}, silicate and/or carbon gathered to form a particle and heavy metals, Ni and Fe in this study were segregated on it. The amount and shape of the residue should be important to control VPT factor. - Highlights: • This paper presents a summary of study results of VPT–TXRF using ISO/TC201/WG2. • Our goal is to analyze the trace metallic contamination on silicon wafer with concentrations below 1 × 10{sup 10} atoms/cm{sup 2}. • The efficiency and mechanism of VPT are discussed under several round robin tests and systematic studies.

  12. X-ray fluorescence in Member States: Argentina. Synchrotron radiation total reflection X-ray fluorescence study of gums

    International Nuclear Information System (INIS)

    Full text: Over the years, the term gums has been used for a wide range of compounds including polysaccharides, terpenes, proteins, and synthetic polymers. In the 1990s, the term more specifically denotes a group of industrially useful polysaccharides or their derivatives that hydrate in hot or cold water to form viscous solutions, dispersions, or gels. Gums are used in industry because their aqueous solutions or dispersions have suspending and stabilizing properties. In addition, gums may produce gels or act as emulsifiers, adhesives, flocculants, binders, film formers, lubricants, or friction reducers, depending on the shape and chemical nature of the particular gum. They have increasingly been used in recent years by industry due to their controlled, reproducible and economical biosynthesis, and their biodegradability. Gums are classified as natural or modified. Natural gums include seaweed extracts, plant exudates, gums from seed or root, and gums obtained by microbial fermentation. Modified (semi-synthetic) gums include cellulose and starch derivatives and certain synthetic gums such as low methoxyl pectin, propylene glycol alginate, and carboxymethyl and hydroxypropyl guar gum. Selected polymers from the different groups were characterised in this work. Specifications of these polymers have to be controlled by European Community, Mercosur, etc. especially for toxic metals in food and pharmaceutical products. Synchrotron Radiation (SR) induced Total Reflection X-ray Fluorescence (SRTXRF) analysis expands the possibilities of conventional TXRF based on X-ray tube excitation. In this study the SRTXRF technique was successfully applied for the quantification of F, Na, Mg, S, K, Ca, V, Cr, Mn, Fe, Ni, Cu, Zn, As and Pb in high-viscosity gum aqueous solutions. The results were analysed from both toxic and alimentary point of view. (author)

  13. Planar solar concentrator featuring alignment-free total-internal-reflection collectors and an innovative compound tracker.

    Science.gov (United States)

    Teng, Tun-Chien; Lai, Wei-Che

    2014-12-15

    This study proposed a planar solar concentrator featuring alignment-free total-internal-reflection (TIR) collectors and an innovative compound tracker. The compound tracker, combining a mechanical single-axis tracker and scrollable prism sheets, can achieve a performance on a par with dual-axis tracking while reducing the cost of the tracking system and increasing its robustness. The alignment-free TIR collectors are assembled on the waveguide without requiring alignment, so the planar concentrator is relatively easily manufactured and markedly increases the feasibility for use in large concentrators. Further, the identical TIR collector is applicable to various-sized waveguide slab without requiring modification, which facilitates flexibility regarding the size of the waveguide slab. In the simulation model, the thickness of the slab was 2 mm, and its maximal length reached 6 m. With an average angular tolerance of ±0.6°, and after considering both the Fresnel loss and the angular spread of the sun, the simulation indicates that the waveguide concentrator of a 1000-mm length provides the optical efficiencies of 62-77% at the irradiance concentrations of 387-688, and the one of a 2000-mm length provides the optical efficiencies of 52-64.5% at the irradiance concentrations of 645-1148. Alternatively, if a 100-mm horizontally staggered waveguide slab is collocated with the alignment-free TIR collectors, the optical efficiency would be greatly improved up to 91.5% at an irradiance concentration of 1098 (C(geo) = 1200X). PMID:25607496

  14. Total reflection X-ray fluorescence analysis of oral fluids of women affected by osteoporosis and osteopenia

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Hector Jorge [Facultad de Matematica Astronomia y Fisica, Universidad Nacional de Cordoba, 5000 Cordoba (Argentina)], E-mail: jsan@famaf.unc.edu.ar; Valentinuzzi, Maria Cecilia [Facultad de Matematica Astronomia y Fisica, Universidad Nacional de Cordoba, 5000 Cordoba (Argentina); Grenon, Miram [Facultad de Odontologia, Universidad Nacional de Cordoba, 5000 Cordoba (Argentina); Abraham, Jose [Facultad de Matematica Astronomia y Fisica, Universidad Nacional de Cordoba, 5000 Cordoba (Argentina)

    2008-12-15

    Osteoporosis is a disease characterized by low bone mass and microarchitectural deterioration of bone tissue, leading to bone fragility and an increased susceptibility to fractures; the early stage of decreased bone density is called osteopenia. More than 200 million people are affected and about 50% of post-menopausic women are expected to develop the disease. Osteoporosis, osteopenia and periodontal disease have in common several risk factors, being hyperthyroidism and smoking habits the most important ones. There is scarce information in the literature about the association between periodontal disease and osteoporosis and/or osteopenia. Some works suggest that osteoporotic women are susceptible to a higher loss of periodontal insertion, alveolar bones, and teeth. Thirty adult post-menopausic women were studied; some of them were healthy (control group) and the rest of them were undergoing some stage of osteoporosis or osteopenia. All the subjects were healthy, non-smokers, not having dental implants, and with communitarian periodontal index higher than 1(CPI > 1). Samples of saliva and gingival crevice fluid were extracted with calibrated micro-capillaries and deposited on Si reflectors. Known amounts of Ga were added to the samples in order to act as internal standard for quantification by the total reflection x-ray fluorescence technique. Experimental concentrations of several elements (P, S, Cl, K, Ca, Cr, Fe, NI, Cu, and Zn) were determined. The concentration of some elements in saliva showed different behavior as compared to gingival crevice fluid. Some critical elements of bone composition, such as Ca and Zn, present very distinguishable behavior. Improvements in the statistics are required for a better assessment of a routine method and to establish some correlation with periodontal disease. TXRF seems to be a promising method to evaluate the evolution of osteoporosis.

  15. Application of CO2 Snow Jet Cleaning in Conjunction with Laboratory Based Total Reflection X-Ray Fluorescence

    Science.gov (United States)

    Schmeling, M.; Burnett, D. S.; Allton, J. H.; Rodriquez, M.; Tripa, C. E.; Veryovkin, I. V.

    2013-01-01

    The Genesis mission was the first mission returning solar material to Earth since the Apollo program [1,2]. Unfortunately the return of the space craft on September 8, 2004 resulted in a crash landing, which shattered the samples into small fragments and exposed them to desert soil and other debris. Thus only small fragments of the original collectors are available, each having different degrees of surface contamination. Thorough surface cleaning is required to allow for subsequent analysis of solar wind material embedded within. An initial cleaning procedure was developed in coordination with Johnson Space Center which focused on removing larger sized particulates and a thin film organic contamination acquired during collection in space [3]. However, many of the samples have additional residues and more rigorous and/or innovative cleaning steps might be necessary. These cleaning steps must affect only the surface to avoid leaching and re-distribution of solar wind material from the bulk of the collectors. To aid in development and identification of the most appropriate cleaning procedures each sample has to be thoroughly inspected before and after each cleaning step. Laboratory based total reflection X-ray fluorescence (TXRF) spectrometry lends itself to this task as it is a non-destructive and surface sensitive analytical method permitting analysis of elements from aluminum onward present at and near the surface of a flat substrate [4]. The suitability of TXRF has been demonstrated for several Genesis solar wind samples before and after various cleaning methods including acid treatment, gas cluster ion beam, and CO2 snow jet [5 - 7]. The latter one is non-invasive and did show some promise on one sample [5]. To investigate the feasibility of CO2 snow jet cleaning further, several flown Genesis samples were selected to be characterized before and after CO2 snow application with sample 61052 being discussed below.

  16. Total reflection X-ray fluorescence analysis of oral fluids of women affected by osteoporosis and osteopenia

    Science.gov (United States)

    Sánchez, Héctor Jorge; Valentinuzzi, María Cecilia; Grenón, Miram; Abraham, José

    2008-12-01

    Osteoporosis is a disease characterized by low bone mass and microarchitectural deterioration of bone tissue, leading to bone fragility and an increased susceptibility to fractures; the early stage of decreased bone density is called osteopenia. More than 200 million people are affected and about 50% of post-menopausic women are expected to develop the disease. Osteoporosis, osteopenia and periodontal disease have in common several risk factors, being hyperthyroidism and smoking habits the most important ones. There is scarce information in the literature about the association between periodontal disease and osteoporosis and/or osteopenia. Some works suggest that osteoporotic women are susceptible to a higher loss of periodontal insertion, alveolar bones, and teeth. Thirty adult post-menopausic women were studied; some of them were healthy (control group) and the rest of them were undergoing some stage of osteoporosis or osteopenia. All the subjects were healthy, non-smokers, not having dental implants, and with communitarian periodontal index higher than 1(CPI > 1). Samples of saliva and gingival crevice fluid were extracted with calibrated micro-capillaries and deposited on Si reflectors. Known amounts of Ga were added to the samples in order to act as internal standard for quantification by the total reflection x-ray fluorescence technique. Experimental concentrations of several elements (P, S, Cl, K, Ca, Cr, Fe, NI, Cu, and Zn) were determined. The concentration of some elements in saliva showed different behavior as compared to gingival crevice fluid. Some critical elements of bone composition, such as Ca and Zn, present very distinguishable behavior. Improvements in the statistics are required for a better assessment of a routine method and to establish some correlation with periodontal disease. TXRF seems to be a promising method to evaluate the evolution of osteoporosis.

  17. Determination of platinum group metal catalyst residues in active pharmaceutical ingredients by means of total reflection X-ray spectrometry

    International Nuclear Information System (INIS)

    The control of metal catalyst residues (i.e., platinum group metals (PGMs)) in different stages of the manufacturing processes of the active pharmaceutical ingredients (APIs) and, especially, in the final product is crucial. For API specimens, there are strict guidelines to limit the levels of metal residues based on their individual levels of safety concern. For PGMs the concentration limit has been established at 10 mg/kg in the API. Therefore great effort is currently being devoted to the development of new and simple procedures to control metals in pharmaceuticals. In the present work, an analytical methodology based on benchtop total reflection X-ray fluorescence spectrometry (TXRF) has been developed for the rapid and simple determination of some PGM catalyst impurities (Rh, Pd, Ir and Pt) in different types of API samples. An evaluation of different sample treatments (dissolution and digestion of the solid pharmaceutical samples) has been carried out and the developed methodologies have been validated according to the analytical parameters to be considered and acceptance criteria for PGM determination according to the United States Pharmacopeia (USP). Limits of quantification obtained for PGM metals were in the range of 2–4 mg/kg which are satisfactory according to current legislation. From the obtained results it is shown that the developed TXRF method can be implemented in the pharmaceutical industries to increase productivity of the laboratory; offering an interesting and complementary analytical tool to other atomic spectroscopic methods. - Highlights: • A TXRF method for PGM catalyst residue determination in API samples is presented. • Analysis can be performed using 10 μL of the internal standardized dissolved API. • The method is rapid, simple and suitable according to the USP requirements

  18. Zinc and cadmium accumulation in single zebrafish (Danio rerio) embryos - A total reflection X-ray fluorescence spectrometry application

    International Nuclear Information System (INIS)

    Trace metals such as Cadmium (Cd) and Zinc (Zn) are known to exhibit adverse effects on many aquatic organisms including early life stages of fish. In contact with contaminated sediment, fish eggs and embryos may be exposed to metals via the water phase as well as via direct contact with contaminated particles. This may result in body burdens that are difficult to predict and may vary according to individual micro scale exposure conditions. The highly sensitive total reflection X-ray fluorescence spectrometry (TXRF) may provide a tool to analyse individual embryos for internal contaminant concentrations and thus helps to develop a better understanding of dose-response relationships. To test this hypothesis, embryos of Danio rerio were exposed to Cd and Zn spiked sediment in different treatments applying an ion exchange resin for modification of bioavailable concentrations. The TXRF analysis indicated individual embryos with dramatically enhanced exposure compared to other individuals despite uniform exposure conditions on a macro scale. Ion exchanger reduced embryo Zn concentrations to values close to control value with a comparably low standard deviation. Cadmium concentrations in embryos were in the range of 4000 to 7000 μg/g with a median of 5740 μg/g. A commercial ion exchanger reduced individual body burdens by a factor 50 to 100. Individual peak body burdens of up to 3160 μg/g were accompanied by reduced weight of the fish eggs due to early death i.e. coagulation. The investigation of exposure and effects on an individual-based scale may significantly help to reduce uncertainty and inconsistencies occurring in conventional analysis of pooled fish embryo samples

  19. Zinc and cadmium accumulation in single zebrafish (Danio rerio) embryos - A total reflection X-ray fluorescence spectrometry application

    Energy Technology Data Exchange (ETDEWEB)

    Mages, Margarete [UFZ - Helmholtz Centre for Environmental Research, Dept. River Ecology Brueckstr. 3a/39114 Magdeburg/Germany (Germany); University of Lueneburg, Institute of Ecology and Environmental Chemistry, Department Environmental Chemistry, Scharnhorststrasse 1/21335 Lueneburg/Germany (Germany)], E-mail: margarete.mages@ufz.de; Bandow, Nicole [UFZ - Helmholtz Centre for Environmental Research, Dept. Effect Directed Analysis, Permoser Strasse 15/ 04318 Leipzig/Germany (Germany); Kuester, Eberhard [UFZ - Helmholtz Centre for Environmental Research, Dept. Bioanalytical Ecotoxicology, Permoser Strasse 15/ 04318 Leipzig/Germany (Germany); Brack, Werner [UFZ - Helmholtz Centre for Environmental Research, Dept. Effect Directed Analysis, Permoser Strasse 15/ 04318 Leipzig/Germany (Germany); Tuempling, Wolf von [UFZ - Helmholtz Centre for Environmental Research, Dept. River Ecology Brueckstr. 3a/39114 Magdeburg/Germany (Germany)

    2008-12-15

    Trace metals such as Cadmium (Cd) and Zinc (Zn) are known to exhibit adverse effects on many aquatic organisms including early life stages of fish. In contact with contaminated sediment, fish eggs and embryos may be exposed to metals via the water phase as well as via direct contact with contaminated particles. This may result in body burdens that are difficult to predict and may vary according to individual micro scale exposure conditions. The highly sensitive total reflection X-ray fluorescence spectrometry (TXRF) may provide a tool to analyse individual embryos for internal contaminant concentrations and thus helps to develop a better understanding of dose-response relationships. To test this hypothesis, embryos of Danio rerio were exposed to Cd and Zn spiked sediment in different treatments applying an ion exchange resin for modification of bioavailable concentrations. The TXRF analysis indicated individual embryos with dramatically enhanced exposure compared to other individuals despite uniform exposure conditions on a macro scale. Ion exchanger reduced embryo Zn concentrations to values close to control value with a comparably low standard deviation. Cadmium concentrations in embryos were in the range of 4000 to 7000 {mu}g/g with a median of 5740 {mu}g/g. A commercial ion exchanger reduced individual body burdens by a factor 50 to 100. Individual peak body burdens of up to 3160 {mu}g/g were accompanied by reduced weight of the fish eggs due to early death i.e. coagulation. The investigation of exposure and effects on an individual-based scale may significantly help to reduce uncertainty and inconsistencies occurring in conventional analysis of pooled fish embryo samples.

  20. Use of total-reflection x-ray fluorescence in search of a biomonitor for environmental pollution in Vietnam

    International Nuclear Information System (INIS)

    The concentration of trace elements in tissues of several animals collected in the Ha Nam province, about 25 km south of Hanoi, Vietnam, has been investigated using total-reflection x-ray fluorescence (TXRF). With this study we wanted to address whether any of the animals were possible candidates for being bio-monitors for the pollution situation in a selected area of Vietnam. We also aim to compare the measured trace element concentrations to those representative to other provinces in Vietnam as well as to other parts of the world. An extensive bio-diversity of animals exists in Vietnam, where many of them play an important economic role in the agricultural breeding and production. The accumulation process of trace elements is still not known for a large number of animals. The parts of the collected animals chosen for analysis were muscle tissue and liver. The specimens were dried under vacuum and kept frozen. Before the TXRF analysis, the solid and dried samples were digested in nitric acid. The analysis was made at the Department of Physics at Chalmers University of Technology and Goeteborg University, Sweden, where a TXRF spectrometer has been developed by the Environmental Physics group. The results show that there could be a large variation in the concentration of trace elements, not only between the different animals but also between tissue parts of the same animal. Obviously, when selecting an organism to be used as a bio-monitor, other factors than the mere concentration of trace elements must be considered. (author)

  1. Variable laser attenuator

    Science.gov (United States)

    Foltyn, Stephen R.

    1988-01-01

    The disclosure relates to low loss, high power variable attenuators comprng one or more transmissive and/or reflective multilayer dielectric filters. The attenuator is particularly suitable to use with unpolarized lasers such as excimer lasers. Beam attenuation is a function of beam polarization and the angle of incidence between the beam and the filter and is controlled by adjusting the angle of incidence the beam makes to the filter or filters. Filters are selected in accordance with beam wavelength.

  2. Impulsive solar X-ray bursts. 4: Polarization, directivity and spectrum of the reflected and total bremsstrahlung radiation from a beam of electrons directed toward the photosphere

    Science.gov (United States)

    Langer, S. H.; Petrosian, V.

    1976-01-01

    A Monte Carlo method is described for evaluation of the spectrum, directivity and polarization of X-rays diffusely reflected from stellar photospheres. the accuracy of the technique is evaluated through comparison with analytic results. Using the characteristics of the incident X-rays of the model for solar X-ray flares, the spectrum, directivity and polarization of the reflected and the total X-ray fluxes are evaluated. The results are compared with observations.

  3. VERTEX: biological implications of total attenuation and chlorophyll and phycoerythrin fluorescence distributions along a 2000 m deep section in the Gulf of Alaska

    Science.gov (United States)

    Broenkow, William W.; Yuen, Marilyn A.; Yarbrough, Mark A.

    1992-04-01

    A 2000 m deep section of total attenuation and chlorophyll and phycoerythrin fluorescence from 26° to 59°N latitude in the northeast Pacific is discussed in terms of inferred biological processes. Photic zone distributions of these quantities vary from nutrient-limited conditions in the subtropics to light-limited conditions in the subarctic. Phycoerythrin-containing organisms, probably Synechococcus, contribute to a strong, near-surface orange fluorescence signal in the Gulf of Alaska. We now recognize that the fluorescence minimum (about 300 m) between the photic zone and the tertiary fluorescence maximum may be related to secondary producers that "repackage" organic matter produced in the photic zone. The tertiary fluorescence maximum (about 1000 m) is a continuous feature of the oxygen minimum zone in the North Pacific. The presence of phycoerythrin in the tertiary maximum is consistent with heterotrophic cyanobacteria and other unidentified microbial assemblages in the oxygen minimum, though there is no strong biological evidence that this is true.

  4. Total reflection x-ray fluorescence (TXRF) - a tool to obtain information about different air masses and air pollution

    International Nuclear Information System (INIS)

    Aerosols are solid particles dissolved in the atmosphere and have strong influence in the earth climate. Their solid surfaces are the only atmospheric medium for condensation of water leading to cloud formation and ultimately to precipitation. Besides their role in cloud formation, the elemental composition of aerosols reveals useful information about air masses and their transport patterns as well as air pollution. The elemental composition can be considered like a fingerprint of an air mass telling the story about its origin and fate. The presence of Al, Ti and Fe for instance indicates a source located in a highly exposed soil or often desert region, whereas Ni, V and Pb can be traced back to anthropogenic activities like fuel combustion or industrial processes. Other important source regions are the oceans, which emit the main aerosol constituents Na, Cl, and S. The concentrations of these elements in the atmosphere are extremely low and long sampling times are necessary to gain reliable results with most of the common analysis techniques. In contrast to this total reflection x-ray fluorescence (TXRF), as a technique capable to cope with tiny sample amounts, offers the unique possibility to reduce collection times to a minimum of minutes to hours. Such short sampling times in turn render it possible to monitor different air masses either passing through a ground based station or -in the ideal case- flown into by a small research aircraft. Different aerosol samples were taken by aircraft during the second aerosol characterization experiment (ACE-2) with sampling times ranging from 15 minutes up to one hour. These filter samples were analyzed by TXRF for trace elements subsequently. Together with background information about back trajectories and size distribution covering the time of sampling the presence of different air masses could be detected. In another project, short-term samples in the Chicago/Lake Michigan area are collected to study the air mass

  5. Determination of lead in clay enameled by X-ray fluorescence technique in Total reflection and by Scanning Electron Microscopy; Determinacion de plomo en esmaltado de barro por Fluorescencia de rayos X en reflexion total y Microscopia Electronica de Barrido

    Energy Technology Data Exchange (ETDEWEB)

    Zarazua O, G.; Carapia M, L. [Instituto Nacional de Investigaciones Nucleares, C.P. 52045 Estado de Mexico (Mexico)

    2000-07-01

    This work has the objective of determining lead free in the glazed commercial stewing pans using the X-ray fluorescence technique in Total reflection (FRX) and the observation and semiquantitative determination of lead by Analytical Scanning Electron Microscopy (ASEM). (Author)

  6. Clonorchis sinensis-derived total protein attenuates airway inflammation in murine asthma model by inducing regulatory T cells and modulating dendritic cell functions.

    Science.gov (United States)

    Jeong, Young-Il; Kim, Seung Hyun; Ju, Jung Won; Cho, Shin Hyeong; Lee, Won Ja; Park, Jin Wook; Park, Yeong-Min; Lee, Sang Eun

    2011-04-22

    Asthma is characterized by Th2-mediated inflammation, resulting in airway hyperresponsiveness (AHR) through airway remodeling. Recent epidemiological and experimental reports have suggested an inverse relationship between the development of allergy and helminth infections. Infection by Clonorchis sinensis, a liver fluke that resides in the bile duct of humans, is endemic predominantly in Asia including Korea and China. Using a murine model for asthma, we investigated the effects of C. sinensis-derived total protein (Cs-TP) on allergen-induced airway inflammation and the mechanism underlying the protective effects of Cs-TP administration on asthma. Treatment with Cs-TP attenuated OVA-induced airway inflammation and methacholine-induced AHR, as well as eosinophilia development, lymphocyte infiltration into the lung, and goblet cell metaplasia. This protective effect of Cs-TP is associated with markedly reduced OVA-specific IgE and Th1/Th2 cytokine production. Moreover, Cs-TP increased the number of CD4(+)CD25(+)Foxp3(+) regulatory T (Treg) cells as well as their suppressive activity. In fact, proliferation of OVA-restimulated splenocytes was suppressed significantly. Cs-TP also inhibited the expression of such co-stimulatory molecules as CD80, CD86, and CD40 in LPS- or OVA-stimulated dendritic cells (DCs), suggesting that Cs-TP could interfere with the capacity of airway DCs to prime naïve T cells. These data demonstrate the capacity of C. sinensis to ameliorate allergic asthma and broaden our understanding of the paradoxical relationship between the allergic immune response and helminth infection. PMID:21440530

  7. Experimental infection of commercial layers with wild or attenuated Salmonella Gallinarum mutant strains: anatomic pathology, total blood cell count and serum protein levels

    Directory of Open Access Journals (Sweden)

    KO Garcia

    2013-06-01

    Full Text Available The aim of the present study was to comparatively evaluate hemogram, blood serum components and anatomopathologic alterations in commercial layers experimentally challenged with an attenuated vaccine candidate strain (SG∆cobS∆cbiA and other two pathogenic strains (SGDcobS and SGNalr of Gallinarum (SG. In total, 280 commercial layers were randomly divided into 4 groups (G1, G2, G3 and G4. At five days of age, birds from groups G1 received approximately 107 colony forming units (CFU of SGDcobS; meanwhile birds from group G2 and G3 received the same dose of SGNalr and SG∆cobS∆cbiA, respectively. Birds from G4 were not infected. At 24 hours before (DBI and 24 hours after (1 DAI, and three (3 DAI, five (5 DAI, seven (7 DAI ten (10 DAI, and fifteen (15 DAI days after the infection, 10 birds of each group were humanely killed and blood samples collected to hematological and serum tests. Samples of liver, spleen, thymus, bursa of Fabricius, kidney and heart were also collected for the histological examination. Birds inoculated with SGDcobS and SGNalr showed similar alterations in hemogram, blood serum components and anatomopathologic exams. On the other hand, the exams of birds inoculated with SG∆cobS∆cbiA strain were similar to those of the uninfected birds. However, changes could be noticed in levels of uric acid and cholesterol during the course of the infection of birds from G3. Decrease in levels of light IgG 3 DAI was also observed in birds from this group. Pyknosis in kidney cells was a microscopic alteration found in birds from G3. Further studies must be done to verify if these alterations will not interfere in the performance of the vaccinate birds with SG∆cobS∆cbiA strain.

  8. Novel Folding Large-Scale Optical Switch Matrix with Total Internal Reflection Mirrors on Silicon-on-Insulator by Anisotropy Chemical Etching

    Institute of Scientific and Technical Information of China (English)

    LIU Jing-Wei; YU Jin-Zhong; CHEN Shao-Wu

    2005-01-01

    A compact optical switch matrix was designed, in which light circuits were folded by total internal reflective (TIR) mirrors. Two key elements, 2 × 2 switch and TIR mirror, have been fabricated on silicon-on-insulator wafer by anisotropy chemical etching. The 2 × 2 switch showed very low power consumption of 140mW and avery high speed of 8 ± 1 μs. An improved design for the TIR mirror was developed, and the fabricated mirror with smooth and vertical reflective facet showed low excess loss of 0.7 ± 0.3 dB at 1.55μm.

  9. Impulsive solar X-ray bursts. III - Polarization, directivity, and spectrum of the reflected and total bremsstrahlung radiation from a beam of electrons directed toward the photosphere

    Science.gov (United States)

    Langer, S. H.; Petrosian, V.

    1977-01-01

    The paper presents the spectrum, directivity, and state of polarization of the bremsstrahlung radiation expected from a beam of high-energy electrons spiraling along radial magnetic field lines toward the photosphere. A Monte Carlo method is then described for evaluation of the spectrum, directivity, and polarization of X-rays diffusely reflected from stellar photospheres. The accuracy of the technique is evaluated through comparison with analytic results. The calculated characteristics of the incident X-rays are used to evaluate the spectrum, directivity, and polarization of the reflected and total X-ray fluxes. The results are compared with observations.

  10. Serum Cystatin C Reflects Angiographic Coronary Collateralization in Stable Coronary Artery Disease Patients with Chronic Total Occlusion

    OpenAIRE

    Shen, Ying; Ding, Feng Hua; Zhang, Rui Yan; Zhang, Qi; Lu, Lin; Shen, Wei Feng

    2015-01-01

    Objective We investigated whether and to what extent cystatin C was associated with angiographic coronary collateralization in patients with stable coronary artery disease and chronic total occlusion. Methods Serum levels of cystatin C and high-sensitive C-reactive protein (hsCRP) and glomerular filtration rate (GFR) were determined in 866 patients with stable angina and angiographic total occlusion of at least one major coronary artery. The degree of collaterals supplying the distal aspect o...

  11. Optical interrupter based in the internal total reflection of spatial solitons at nonlinear saturable interfaces; Interruptores opticos basados en reflexion interna total de solitones espaciales en interfaces no lineales saturables

    Energy Technology Data Exchange (ETDEWEB)

    Alvarado-Mendez, E.; Torres-Cisneros, M.; Gutierrez-Hernandez, D. A.; Andrade-Lucio, J. A.; Rojas-Lagunas, R.; Pedraza-Ortega, J. C.; Torres Cisneros, G. E. [Universidad de Guanajuato, Guanajuato (Mexico); Sanchez Mondragon, J. J. [Universidad Autonoma del Estado de Morelos, Morelos (Mexico); Flores-Alvarado, G. [Preparatoria por Cooperacion Domingo Arenas, Tlaxcala (Mexico)

    2001-06-01

    We study the reflection of one-dimensional spatial soliton at the nonlinear interface between a saturable type medium and linear medium. Our study makes emphasis on determining the physical conditions under which the beam reflected by the interface is still a spatial soliton. Depended the incidence angle we find three critical regions for spatial solitons in the interface. We observed nonlinear Goos- Haechen shift is determined if reflection angle are conserved. Finally, we present preliminary experimental results in SBN61:Ce of the total internal reflection of one dimensional beam. [Spanish] Estudiamos la reflexion de un soliton espacial unidimensional en una interfase formada por un medio no lineal saturable y un medio lineal. Nuestros estudios hacen enfasis en determinar las condiciones fisicas bajo las cuales el haz reflejado por la interfase no lineal sigue siendo soliton. Encontramos tres regiones criticas para un soliton especial en la interfase, dependiendo del valor que tome el angulo de incidencia. Asi mismo observamos corrimiento Goos-Haechen no lineal que es determinante para la conservacion del angulo de reflexion. Finalmente, presentamos resultados preliminares experimentales en SBN61:Ce de la reflexion interna total de un haz unidimensional.

  12. Direct analysis of blood serum by total reflection X-ray fluorescence spectrometry and application of an artificial neural network approach for cancer diagnosis*1

    Science.gov (United States)

    Hernández-Caraballo, Edwin A.; Marcó-Parra, Lué M.

    2003-12-01

    Iron, copper, zinc and selenium were determined directly in serum samples from healthy individuals ( n=33) and cancer patients ( n=27) by total reflection X-ray fluorescence spectrometry using the Compton peak as internal standard [L.M. Marcó P. et al., Spectrochim. Acta Part B 54 (1999) 1469-1480]. The standardized concentrations of these elements were used as input data for two-layer artificial neural networks trained with the generalized delta rule in order to classify such individuals according to their health status. Various artificial neural networks, comprising a linear function in the input layer, a hyperbolic tangent function in the hidden layer and a sigmoid function in the output layer, were evaluated for such a purpose. Of the networks studied, the (4:4:1) gave the highest estimation (98%) and prediction rates (94%). The latter demonstrates the potential of the total reflection X-ray fluorescence spectrometry/artificial neural network approach in clinical chemistry.

  13. Direct analysis of blood serum by total reflection X-ray fluorescence spectrometry and application of an artificial neural network approach for cancer diagnosis

    International Nuclear Information System (INIS)

    Iron, copper, zinc and selenium were determined directly in serum samples from healthy individuals (n=33) and cancer patients (n=27) by total reflection X-ray fluorescence spectrometry using the Compton peak as internal standard [L.M. Marco P. et al., Spectrochim. Acta Part B 54 (1999) 1469-1480]. The standardized concentrations of these elements were used as input data for two-layer artificial neural networks trained with the generalized delta rule in order to classify such individuals according to their health status. Various artificial neural networks, comprising a linear function in the input layer, a hyperbolic tangent function in the hidden layer and a sigmoid function in the output layer, were evaluated for such a purpose. Of the networks studied, the (4:4:1) gave the highest estimation (98%) and prediction rates (94%). The latter demonstrates the potential of the total reflection X-ray fluorescence spectrometry/artificial neural network approach in clinical chemistry

  14. Comparative study of multi-element determination using inductively coupled plasma mass spectrometry, total reflection X-ray fluorescence spectrometry and neutron activation analysis

    International Nuclear Information System (INIS)

    The analytical capabilities of inductively coupled plasma mass spectrometry, total reflection X-ray fluorescence spectrometry and neutron activation analysis were compared. The data originated from the parallel analyses of spinach, cabbage and domestic sludge samples, which were used in inter-laboratory tests to monitor precision and accuracy. The determined concentrations range from 40 mg g-1 to 20 ng g-1 and the analytical errors from 2 to 30%. The extensive results and the reliability of the techniques are discussed. (orig.)

  15. Total reflection X-ray fluorescence spectrometric determination of elements in water hyacinth from the Lerma River

    International Nuclear Information System (INIS)

    The Lerma River is one of the most polluted body water in Mexico. For this reason, only the highly resistant organisms such as water hyacinth are able to reproduce in this river. The aim of this work was to evaluate the concentration of K, S, Fe, Ca, Mn, Ti, Zn, Sr, Rb, Cu, Cr, Ni, Pb and Br in roots of water hyacinth (Eichhornia crassipes) from the Lerma River. The samples were collected from five sites in the river and analyzed in triplicate using a TXRF Spectrometer 'TX-2000 Ital Structures' with a Si(Li) detector and a resolution of 140 eV (FWHM) at Mn Kα. A Mo tube (40 kV, 30 mA) with 17.4 KeV excitation energy was used for a counting time of 500 s. Results show that the average metal concentration in the water hyacinth roots decrease in the following order: K (9698.2 μg/g) > S (7593.3 μg/g) > Fe (4406.6 μg/g) > Ca (2601.8 μg/g) > Mn (604.2 μg/g) > Ti (230.7 μg/g) > Zn (51.65 μg/g) > Sr (43.55 μg/g) > Rb (18.61 μg/g) > Cu (12.78 μg/g) > Cr (6.45 μg/g) > Ni (4.68 μg/g) > Pb (4.32 μg/g) > Br (4.31 μg/g) and the bioconcentration factors in the water hyacinth decrease in the sequence: Ti > Fe > Mn > Cu > Ni > Zn > S > Pb > Rb > K > Cr > Sr > Br > Ca. The concentrations in roots of water hyacinth reflect the high pollution level of the river.

  16. Total reflection X-ray fluorescence spectrometric determination of elements in water hyacinth from the Lerma River

    Energy Technology Data Exchange (ETDEWEB)

    Tejeda, S. [Instituto Nacional de Investigaciones Nucleares, Gerencia de Ciencias Ambientales, Apartado Postal 18-1027, Mexico D.F., C.P. 11801 (Mexico); Instituto Tecnologico de Toluca, Division de Estudios de Posgrado e Investigacion, Apartado Postal 890, Metepec, C.P. 52149 (Mexico); Zarazua, G., E-mail: graciela.zarazua@inin.gob.m [Instituto Nacional de Investigaciones Nucleares, Gerencia de Ciencias Ambientales, Apartado Postal 18-1027, Mexico D.F., C.P. 11801 (Mexico); Avila-Perez, P. [Instituto Nacional de Investigaciones Nucleares, Gerencia de Ciencias Ambientales, Apartado Postal 18-1027, Mexico D.F., C.P. 11801 (Mexico); Instituto Tecnologico de Toluca, Division de Estudios de Posgrado e Investigacion, Apartado Postal 890, Metepec, C.P. 52149 (Mexico); Carapia-Morales, L. [Instituto Nacional de Investigaciones Nucleares, Gerencia de Ciencias Ambientales, Apartado Postal 18-1027, Mexico D.F., C.P. 11801 (Mexico); Martinez, T. [Universidad Nacional Autonoma de Mexico, Facultad de Quimica, Mexico D.F. (Mexico)

    2010-06-15

    The Lerma River is one of the most polluted body water in Mexico. For this reason, only the highly resistant organisms such as water hyacinth are able to reproduce in this river. The aim of this work was to evaluate the concentration of K, S, Fe, Ca, Mn, Ti, Zn, Sr, Rb, Cu, Cr, Ni, Pb and Br in roots of water hyacinth (Eichhornia crassipes) from the Lerma River. The samples were collected from five sites in the river and analyzed in triplicate using a TXRF Spectrometer 'TX-2000 Ital Structures' with a Si(Li) detector and a resolution of 140 eV (FWHM) at Mn K{alpha}. A Mo tube (40 kV, 30 mA) with 17.4 KeV excitation energy was used for a counting time of 500 s. Results show that the average metal concentration in the water hyacinth roots decrease in the following order: K (9698.2 {mu}g/g) > S (7593.3 {mu}g/g) > Fe (4406.6 {mu}g/g) > Ca (2601.8 {mu}g/g) > Mn (604.2 {mu}g/g) > Ti (230.7 {mu}g/g) > Zn (51.65 {mu}g/g) > Sr (43.55 {mu}g/g) > Rb (18.61 {mu}g/g) > Cu (12.78 {mu}g/g) > Cr (6.45 {mu}g/g) > Ni (4.68 {mu}g/g) > Pb (4.32 {mu}g/g) > Br (4.31 {mu}g/g) and the bioconcentration factors in the water hyacinth decrease in the sequence: Ti > Fe > Mn > Cu > Ni > Zn > S > Pb > Rb > K > Cr > Sr > Br > Ca. The concentrations in roots of water hyacinth reflect the high pollution level of the river.

  17. Total reflection X-ray fluorescence spectrometric determination of elements in water hyacinth from the Lerma River

    Science.gov (United States)

    Tejeda, S.; Zarazúa, G.; Ávila-Pérez, P.; Carapia-Morales, L.; Martínez, T.

    2010-06-01

    The Lerma River is one of the most polluted body water in Mexico. For this reason, only the highly resistant organisms such as water hyacinth are able to reproduce in this river. The aim of this work was to evaluate the concentration of K, S, Fe, Ca, Mn, Ti, Zn, Sr, Rb, Cu, Cr, Ni, Pb and Br in roots of water hyacinth ( Eichhornia crassipes) from the Lerma River. The samples were collected from five sites in the river and analyzed in triplicate using a TXRF Spectrometer 'TX-2000 Ital Structures' with a Si(Li) detector and a resolution of 140 eV (FWHM) at Mn Kα. A Mo tube (40 kV, 30 mA) with 17.4 KeV excitation energy was used for a counting time of 500 s. Results show that the average metal concentration in the water hyacinth roots decrease in the following order: K (9698.2 µg/g) > S (7593.3 µg/g) > Fe (4406.6 µg/g) > Ca (2601.8 µg/g) > Mn (604.2 µg/g) > Ti (230.7 µg/g) > Zn (51.65 µg/g) > Sr (43.55 µg/g) > Rb (18.61 µg/g) > Cu (12.78 µg/g) > Cr (6.45 µg/g) > Ni (4.68 µg/g) > Pb (4.32 µg/g) > Br (4.31 µg/g) and the bioconcentration factors in the water hyacinth decrease in the sequence: Ti > Fe > Mn > Cu > Ni > Zn > S > Pb > Rb > K > Cr > Sr > Br > Ca. The concentrations in roots of water hyacinth reflect the high pollution level of the river.

  18. Total internal reflection fluorescence (TIRF) microscopy for real-time imaging of nanoparticle-cell plasma membrane interaction

    DEFF Research Database (Denmark)

    Parhamifar, Ladan; Moghimi, Seyed Moien

    2012-01-01

    Nanoparticulate systems are widely used for site-specific drug and gene delivery as well as for medical imaging. The mode of nanoparticle-cell interaction may have a significant effect on the pathway of nanoparticle internalization and subsequent intracellular trafficking. Total internal reflecti...... effect by lasers in TIRF microscopy is considerably less when using fluorescent nanoparticles and it reduces photo-induced cytotoxicity during visualization of live-cell events since it only illuminates the specific area near or at the plasma membrane....... fluorescence (TIRF) microscopy allows for real-time monitoring of nanoparticle-membrane interaction events, which can provide vital information in relation to design and surface engineering of therapeutic nanoparticles for cell-specific targeting. In contrast to other microscopy techniques, the bleaching...

  19. Estimation of direct, diffuse, and total FPARs from Landsat surface reflectance data and ground-based estimates over six FLUXNET sites

    Science.gov (United States)

    Li, Wenjuan; Fang, Hongliang

    2015-04-01

    The fraction of photosynthetically active radiation (PAR) absorbed by green elements (FPAR) is an essential climate variable (ECV) in quantifying canopy absorbed PAR (APAR) and gross and net primary production. It has been demonstrated that FPAR is larger under totally diffuse than clear sky conditions because all canopy parts can absorb lights effectively under diffuse conditions. The direct and diffuse FPARs are defined, therefore, as the FPAR values obtained under clear (most sunny) and overcast (most cloudy) conditions, respectively, and FPAR represents the summed canopy absorption efficiency for both direct and diffuse PAR. Satellite FPAR products, such as MODIS, GEOV1, MERIS, and JRC-TIP, have been generated at different temporal and spatial resolutions. Except for JRC-TIP which generates direct and diffuse FPARs separately, all the other products typically correspond to the instantaneous black-sky FPAR under direct illumination only. However, even under fully clear sky conditions, the proportion of diffuse PAR over the surface cannot be ignored. Otherwise, FPAR will be underestimated, especially for small leaf area index (LAI) region. To address this, the present study developed a new approach to estimate direct, diffuse, and total FPARs, separately, from Landsat 30m surface reflectance data. Field-measured direct and diffuse FPARs were first derived for crops, deciduous broadleaf forests, and evergreen needleleaf forests at six FLUXNET sites. Then, a coupled soil-leaf-canopy (SLC) radiative transfer model was used to simulate surface reflectance under direct and diffuse illumination conditions, respectively. Direct, diffuse, and total FPARs were estimated by comparing Landsat-5 Thematic Mapper (TM) data and simulated surface reflectances using a lookup table approach. The differences between the Landsat-estimated and the field-measured FPARs are less than 0.05 (10%). The diffuse FPAR is higher than the direct FPAR by up to 19.38%, whereas the total FPAR is

  20. Real-time feedback control using online attenuated total reflection Fourier transform infrared (ATR FT-IR) spectroscopy for continuous flow optimization and process knowledge.

    Science.gov (United States)

    Skilton, Ryan A; Parrott, Andrew J; George, Michael W; Poliakoff, Martyn; Bourne, Richard A

    2013-10-01

    The use of automated continuous flow reactors is described, with real-time online Fourier transform infrared spectroscopy (FT-IR) analysis to enable rapid optimization of reaction yield using a self-optimizing feedback algorithm. This technique has been applied to the solvent-free methylation of 1-pentanol with dimethyl carbonate using a γ-alumina catalyst. Calibration of the FT-IR signal was performed using gas chromatography to enable quantification of yield over a wide variety of flow rates and temperatures. The use of FT-IR as a real-time analytical technique resulted in an order of magnitude reduction in the time and materials required compared to previous studies. This permitted a wide exploration of the parameter space to provide process understanding and validation of the optimization algorithms. PMID:24067568

  1. Monitoring of an esterification reaction by on-line direct liquid sampling mass spectrometry and in-line mid infrared spectrometry with an attenuated total reflectance probe

    Energy Technology Data Exchange (ETDEWEB)

    Owen, Andrew W.; McAulay, Edith A.J. [WestCHEM, Department of Pure and Applied Chemistry and CPACT, University of Strathclyde, 295 Cathedral Street, Glasgow, G1 1XL (United Kingdom); Nordon, Alison, E-mail: alison.nordon@strath.ac.uk [WestCHEM, Department of Pure and Applied Chemistry and CPACT, University of Strathclyde, 295 Cathedral Street, Glasgow, G1 1XL (United Kingdom); Littlejohn, David, E-mail: d.littlejohn@strath.ac.uk [WestCHEM, Department of Pure and Applied Chemistry and CPACT, University of Strathclyde, 295 Cathedral Street, Glasgow, G1 1XL (United Kingdom); Lynch, Thomas P. [WestCHEM, Department of Pure and Applied Chemistry and CPACT, University of Strathclyde, 295 Cathedral Street, Glasgow, G1 1XL (United Kingdom); Lancaster, J. Steven [Hull Research and Technology Centre, BP Chemicals, Hull, HU12 8DS (United Kingdom); Wright, Robert G. [Thermo Fisher Scientific, Winsford, Cheshire, CW7 3GA (United Kingdom)

    2014-11-07

    Highlights: • High efficiency thermal vaporiser designed and used for on-line reaction monitoring. • Concentration profiles of all reactants and products obtained from mass spectra. • By-product formed from the presence of an impurity detected by MS but not MIR. • Mass spectrometry can detect trace and bulk components unlike molecular spectrometry. - Abstract: A specially designed thermal vaporiser was used with a process mass spectrometer designed for gas analysis to monitor the esterification of butan-1-ol and acetic anhydride. The reaction was conducted at two scales: in a 150 mL flask and a 1 L jacketed batch reactor, with liquid delivery flow rates to the vaporiser of 0.1 and 1.0 mL min{sup −1}, respectively. Mass spectrometry measurements were made at selected ion masses, and classical least squares multivariate linear regression was used to produce concentration profiles for the reactants, products and catalyst. The extent of reaction was obtained from the butyl acetate profile and found to be 83% and 76% at 40 °C and 20 °C, respectively, at the 1 L scale. Reactions in the 1 L reactor were also monitored by in-line mid-infrared (MIR) spectrometry; off-line gas chromatography (GC) was used as a reference technique when building partial least squares (PLS) multivariate calibration models for prediction of butyl acetate concentrations from the MIR spectra. In validation experiments, good agreement was achieved between the concentration of butyl acetate obtained from in-line MIR spectra and off-line GC. In the initial few minutes of the reaction the profiles for butyl acetate derived from on-line direct liquid sampling mass spectrometry (DLSMS) differed from those of in-line MIR spectrometry owing to the 2 min transfer time between the reactor and mass spectrometer. As the reaction proceeded, however, the difference between the concentration profiles became less noticeable. DLSMS had advantages over in-line MIR spectrometry as it was easier to generate concentration profiles for all the components in the reaction. Also, it was possible to detect the presence of a simulated impurity of ethanol (at levels of 2.6 and 9.1% mol/mol) in butan-1-ol, and the resulting production of ethyl acetate, by DLSMS, but not by in-line MIR spectrometry.

  2. Monitoring of an esterification reaction by on-line direct liquid sampling mass spectrometry and in-line mid infrared spectrometry with an attenuated total reflectance probe

    International Nuclear Information System (INIS)

    Highlights: • High efficiency thermal vaporiser designed and used for on-line reaction monitoring. • Concentration profiles of all reactants and products obtained from mass spectra. • By-product formed from the presence of an impurity detected by MS but not MIR. • Mass spectrometry can detect trace and bulk components unlike molecular spectrometry. - Abstract: A specially designed thermal vaporiser was used with a process mass spectrometer designed for gas analysis to monitor the esterification of butan-1-ol and acetic anhydride. The reaction was conducted at two scales: in a 150 mL flask and a 1 L jacketed batch reactor, with liquid delivery flow rates to the vaporiser of 0.1 and 1.0 mL min−1, respectively. Mass spectrometry measurements were made at selected ion masses, and classical least squares multivariate linear regression was used to produce concentration profiles for the reactants, products and catalyst. The extent of reaction was obtained from the butyl acetate profile and found to be 83% and 76% at 40 °C and 20 °C, respectively, at the 1 L scale. Reactions in the 1 L reactor were also monitored by in-line mid-infrared (MIR) spectrometry; off-line gas chromatography (GC) was used as a reference technique when building partial least squares (PLS) multivariate calibration models for prediction of butyl acetate concentrations from the MIR spectra. In validation experiments, good agreement was achieved between the concentration of butyl acetate obtained from in-line MIR spectra and off-line GC. In the initial few minutes of the reaction the profiles for butyl acetate derived from on-line direct liquid sampling mass spectrometry (DLSMS) differed from those of in-line MIR spectrometry owing to the 2 min transfer time between the reactor and mass spectrometer. As the reaction proceeded, however, the difference between the concentration profiles became less noticeable. DLSMS had advantages over in-line MIR spectrometry as it was easier to generate concentration profiles for all the components in the reaction. Also, it was possible to detect the presence of a simulated impurity of ethanol (at levels of 2.6 and 9.1% mol/mol) in butan-1-ol, and the resulting production of ethyl acetate, by DLSMS, but not by in-line MIR spectrometry

  3. Rapid Identification of Thermoplastic Elastomer of Polyvinyl Chloride by Attenuated Total Reflection Infrared Spectrography%FTIR-ATR法快速鉴定T-PVC

    Institute of Scientific and Technical Information of China (English)

    俞雄飞; 张伟

    2005-01-01

    以环己酮为溶剂,无水乙醇为沉淀剂,溶解-沉淀法消除增塑剂的干扰,以锗晶体为反射晶体,衰减全反射红外光谱法定性测定聚氯乙烯成分.该法简单、快速、安全、准确.

  4. Systematic Assessment of Attenuated Total Reflectance-Fourier Transforms Infrared Spectroscopy Coupled with Multivariate Analysis for Forensic Analysis of Black Ball-point Pen Inks

    International Nuclear Information System (INIS)

    This manuscript aims to provide a new and non-destructive method for systematic analysis of inks on a questioned document. Ink samples were analyzed in situ on the paper substrate by micro-ATR-FTIR spectroscopy and the data obtained was processed and evaluated by a series of multivariate chemometrics. Absorbance value from wavenumbers of 2000-675 cm-1 were first processed by cluster analysis (CA), followed by principal component analysis (PCA) to form a set of new variables. Subsequently, the variables set was used for classification, differentiation and identification of 155 sample pens that comprise nine different brands. Results show that nine black ball-point pen brands could be classified into three main groups via discriminant analysis (DA). Differentiation analyses of nine different pen brands performed using one-way ANOVA indicated only two pairs of brands cannot be differentiated at 95 % confidence interval. Finally an identification flow chart was proposed to determine the brand of unknown pen inks. As a conclusion, the proposed method for extracting and creating a new variable set from infrared spectrum was evaluated to be satisfactory for systematic analysis of inks based on their infrared spectrum. (author)

  5. Attenuated total reflectance-Fourier transform infrared spectroscopy coupled with multivariate analysis for measurement of acesulfame-K in diet foods.

    Science.gov (United States)

    Shim, J Y; Cho, I K; Khurana, H K; Li, Q X; Jun, S

    2008-06-01

    Fourier transform infrared (FTIR) spectroscopy was investigated as a method for analysis of acesulfame-K content after a simple extraction procedure for certain commercial diet food samples. Partial least squares (PLS) models were developed for prediction of acesulfame-K using select spectral ranges on the basis of relevant IR absorption bands associated with acesulfame-K. The acesulfame-K content of test food samples was predicted accurately in the fingerprint region between 1100 and 1300 cm(-1) with a maximum prediction error of 9.82% when compared with conventional HPLC method. The PLS was found to be a consistently better predictor when both PLS and principal component regression (PCR) analyses were used for quantification of acesulfame-K. The developed procedure was further validated by comparing with HPLC results as well as recovery studies. As a quick tool, the method developed is expected to be used for routine estimation of acesulfame-K in commercial products. PMID:18576989

  6. Trace element analysis of mineral and tap water samples using total reflection x-ray fluorescence (TXRF)

    International Nuclear Information System (INIS)

    Results of trace element analysis by TXRF of tap water and various brands of bottled mineral water samples which are representative of local and imported brands sold in Nairobi are reported. The variation in elemental concentrations in water samples analyzed were as follows: potassium (K) 0.2 to 28.9 μg/ml; calcium (Ca) 2.2 to 120 μg/ml; titanium (Ti) 11 to 60 μg/l; manganese (Mn) 8 to 670 μg/l; iron (Fe) 31 to 540 μg/l; copper (Cu) 8 to 30 μg/l; zinc (Zn) 8 to 4730 μg/l; bromine (Br) 9 to 248 μg/l; rubidium (Rb) 10 to 40 μg/l and strontium (Sr) 10 to 1000 μg/l. Local mineral water samples contain higher levels of trace elements; manganese (Mn), zinc (Zn), bromine (Br), rubidium (Rb) and strontium (Sr) as compared to the imported brands. Principal component analysis of the results revealed three component loading factors clusters for: rubidium (Rb), strontium (Sr) and calcium (Ca); titanium (Ti), iron (Fe), bromine (Br), and zinc (Zn); zinc (Zn), manganese (Mn) and potassium (K) respectively. The percentage of total variance explained by the components was 31.4, 27.3, and 14.8 respectively. In this study, we also found that a limited spread of 5-6 mm for a 10 μl sample was achieved when the quartz sample carrier was dried in a low pressure (300 mbar) oven at 70 oC for 10 hours. (author)

  7. The use of multilayer monochromators and rotating-anode X-ray tubes in total-reflection X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Total-reflection x-ray fluorescence analysis (TXRF) has become a powerful analytical tool for ultra trace element analysis down to the ppt - level (parts per trillion). A further improvement of the method is achieved by monoenergetic excitation of the sample using synthetic multilayer structures as monochromators. These multilayers are better suited than crystal monochromators in TXRF due to their broader relative energy bandwidth. Advantages and disadvantages of using a W/C multilayer structure in TXRF are discussed. A new multifunctional vacuum chamber was constructed to compare monoenergetic and full spectrum excitation under optimized measuring geometries using rotating and standing anode x-ray tubes as primary radiation sources. Detection limits (extrapolated for a measuring time of 1000 s) of 170 femtogram (170 x 10-15 g) were obtained for the element Mn with full spectrum excitation (rotating Cu-anode). The quantitative analysis is substantially simplified applying monoenergetic excitation since fundamental parameters from tables can be used for elemental sensitivities. No more multielement standards are necessary for establishing calibration curves. Corrections for absorption of the fluorescence radiation in the sample can be neglected due to minute sample masses in TXRF (thin film approximation). The excitation energy is tuned by the multilayer using the bremsstrahlung and characteristic lines of different anode materials (W, Mo) to obtain selective excitation of certain elements in the sample. The multilayer monochromator is compared to total-reflection high energy cut-off filters as a device for modifying the primary spectrum

  8. Adjustable Optical-Fiber Attenuator

    Science.gov (United States)

    Buzzetti, Mike F.

    1994-01-01

    Adjustable fiber-optic attenuator utilizes bending loss to reduce strength of light transmitted along it. Attenuator functions without introducing measurable back-reflection or insertion loss. Relatively insensitive to vibration and changes in temperature. Potential applications include cable television, telephone networks, other signal-distribution networks, and laboratory instrumentation.

  9. Prediction of purine derivatives, creatinine and total nitrogen concentrations in urine by FT-Near-lnfrared Reflectance spectroscopy (FT-NIR)

    International Nuclear Information System (INIS)

    The objective of this study was to provide an alternative method for the determination of purine derivatives (PD, which include allantoin, uric acid, hypoxanthine and xanthine), creatinine and total nitrogen (N) concentrations in urine. About 180 urine samples from cattle, buffaloes and rabbit were collected and analyzed for PD by HPLC, creatinine by spectrophotometry and N by Kjeldahl method. The urine samples were then analyzed by Fourier Transformed Near Infrared Reflectance Spectroscopy (FT-NIR) to find conformity between this technique and the HPLC and colorimetric methods. FT-NIR can predict allantoin, uric acid, hypoxanthine, xanthine, creatinine, total N and sum of N in both allantoin and uric acid with a satisfactory level of accuracy: the determination coefficient (r2) of validation ranged from 0.888% for uric acid to 0.982% for total N. The coefficients of determination for allantoin, creatinine and sum of N in both allantoin and uric acid were 0.92, 0.894 and 0.90%, respectively. Hypoxanthine and xanthine in urine samples were not detectable by NIRS, probably because of their low concentrations, and therefore they were not considered for instrumental calibration. (author)

  10. A sensitive method for determining total vanadium in water samples using colorimetric-solid-phase extraction-fiber optic reflectance spectroscopy

    International Nuclear Information System (INIS)

    A selective colorimetric-solid-phase extraction (C-SPE) method for the determination of total vanadium in water samples was developed. This method introduced a new variation of C-SPE. The colour reaction is based on the reaction of vanadium(V) ternary complex formed with 1-(2-Pyridylazo)-2-naphtol (PAN) in the presence hydrogen peroxide (H2O2). In this technique, the target analytes in samples are extracted onto solid matrix loaded with a colorimetric reagent and then quantified directly on the adsorbent surface by using a miniature fiber optic reflectance spectrometer. The measurements were carried out at a wavelength of 589.4 nm since it yielded the largest divergence different in reflectance spectra before and after reaction with the vanadium. The overall time required for the C-SPE procedure was ∼20 min. The amount of concentrated V is then determined in a few seconds by using miniature reflectance spectrometer. At the optimal conditions, a calibration curve was constructed, revealing a linear range of 0.05-0.52 mg L-1 and a detection limit as low as 0.01 mg L-1 while the RSD lower than 2.8%. In order to verify the accuracy of the method, a certified reference water samples (TMDA) were analysed and the results obtained were in good agreement with the certified values. The proposed method was applied to the determination of vanadium in tap water, seawater samples with a recovery for the spiked samples in the range of 98-102%.

  11. Imaging exocytosis of single glucagon-like peptide-1 containing granules in a murine enteroendocrine cell line with total internal reflection fluorescent microscopy

    International Nuclear Information System (INIS)

    To analyze the exocytosis of glucagon-like peptide-1 (GLP-1) granules, we imaged the motion of GLP-1 granules labeled with enhanced yellow fluorescent protein (Venus) fused to human growth hormone (hGH-Venus) in an enteroendocrine cell line, STC-1 cells, by total internal reflection fluorescent (TIRF) microscopy. We found glucose stimulation caused biphasic GLP-1 granule exocytosis: during the first phase, fusion events occurred from two types of granules (previously docked granules and newcomers), and thereafter continuous fusion was observed mostly from newcomers during the second phase. Closely similar to the insulin granule fusion from pancreatic β cells, the regulated biphasic exocytosis from two types of granules may be a common mechanism in glucose-evoked hormone release from endocrine cells.

  12. Three-dimensional particle tracking around microstructures in water via total internal reflection fluorescence microscopy and refractive-index-matching method

    Science.gov (United States)

    Unno, Noriyuki; Nakata, Shuichiro; Satake, Shin-ichi; Taniguchi, Jun

    2016-07-01

    Multilayer nanoparticle image velocimetry (MnPIV) with a refractive-index-matching method is powerful technique for x- y- z (3D) flow measurement, because it can detect the 3D position of fluorescent particles with submicron resolution. In MnPIV, the intensity of fluorescence of a particle is used to estimate its z-position. However, it has been difficult to measure 3D flows around microstructures in water by total internal reflection fluorescence microscopy because of light scattering caused by the different refractive indices of the structures and the working fluid. By using a thermal nanoimprinting technique, we succeeded in fabricating microstructures from a polymer resin whose refractive index is equal to that of water, and we used these microstructures to perform MnPIV in water. As a result of the match between the refractive index of water and that of the microstructures, we were able to perform 3D tracking of nanoparticles around the microstructures in water.

  13. Efficient isotope ratio analysis of uranium particles in swipe samples by total-reflection x-ray fluorescence spectrometry and secondary ion mass spectrometry

    International Nuclear Information System (INIS)

    A new particle recovery method and a sensitive screening method were developed for subsequent isotope ratio analysis of uranium particles in safeguards swipe samples. The particles in the swipe sample were recovered onto a carrier by means of vacuum suction-impact collection method. When grease coating was applied to the carrier, the recovery efficiency was improved to 48±9%, which is superior to that of conventionally-used ultrasoneration method. Prior to isotope ratio analysis with secondary ion mass spectrometry (SIMS), total reflection X-ray fluorescence spectrometry (TXRF) was applied to screen the sample for the presence of uranium particles. By the use of Si carriers in TXRF analysis, the detection limit of 22 pg was achieved for uranium. By combining these methods with SIMS, the isotope ratios of 235U/238U for individual uranium particles were efficiently determined. (author)

  14. Application of the total reflection X-ray fluorescence method to the elemental analysis of brain tumors of different types and grades of malignancy

    Energy Technology Data Exchange (ETDEWEB)

    Lankosz, M.W., E-mail: Marek.Lankosz@fis.agh.edu.pl [Faculty of Physics and Applied Computer Science, AGH University of Science and Technology, Krakow (Poland); Grzelak, M.; Ostachowicz, B.; Wandzilak, A.; Szczerbowska-Boruchowska, M.; Wrobel, P. [Faculty of Physics and Applied Computer Science, AGH University of Science and Technology, Krakow (Poland); Radwanska, E.; Adamek, D. [Department of Neuropathology, Chair of Pathomorphology, Faculty of Medicine. Jagiellonian University, Krakow (Poland)

    2014-11-01

    The process of carcinogenesis may influence normal biochemical reactions leading to alterations in the elemental composition of the tissue. Total reflection X-ray fluorescence analysis (TXRF) was applied to the elemental analysis of different brain tumors. The following elements were present in all the neoplastic tissues analyzed: K, Ca, Fe, Cu, Zn and Rb. The results of the analysis showed that the elemental composition of a relatively small fragment of tissue represents satisfactorily the biochemical “signature” of a cancer. On the basis of the element concentrations determined, it was possible to differentiate between some types of brain tumors. - Highlights: • Elemental composition represents the biochemical signature of brain cancer. • The element levels differentiate some types of brain tumors. • TXRF spectrometry is a useful tool for elemental trace analysis of brain cancer.

  15. Application of the total reflection X-ray fluorescence method to the elemental analysis of brain tumors of different types and grades of malignancy

    International Nuclear Information System (INIS)

    The process of carcinogenesis may influence normal biochemical reactions leading to alterations in the elemental composition of the tissue. Total reflection X-ray fluorescence analysis (TXRF) was applied to the elemental analysis of different brain tumors. The following elements were present in all the neoplastic tissues analyzed: K, Ca, Fe, Cu, Zn and Rb. The results of the analysis showed that the elemental composition of a relatively small fragment of tissue represents satisfactorily the biochemical “signature” of a cancer. On the basis of the element concentrations determined, it was possible to differentiate between some types of brain tumors. - Highlights: • Elemental composition represents the biochemical signature of brain cancer. • The element levels differentiate some types of brain tumors. • TXRF spectrometry is a useful tool for elemental trace analysis of brain cancer

  16. Monitoring environmental pollution of trace elements in tree-rings by synchrotron radiation total reflection X-ray fluorescence analysis (SR-TXRF)

    International Nuclear Information System (INIS)

    This paper aims to study the environmental pollution in the tree development, as a manner to evaluate its use as bioindicator in urban and country sides. The sample collecting was carry out in Piracicaba city, Sao Paulo State, that presents high level of environmental contamination of the water, soil and air, due industrial activities, vehicles combustion, sugar-cane leaves burning in the harvesting, etc. It was selected the Caesalpinia peltophoroides ('Sibipiruna') specie because its very used in urban arborization. It was employed the analytical technique named total reflection X-ray fluorescence (TXRF) to identify and quantify the elements and metals of nutritional and toxicological importance in the wood samples. The analysis was done in the Brazilian Synchrotron Light Laboratory, using a white beam for excitation and a Si(Li) detector for characteristic X-ray detection. It was quantified the P, K, Ca, Ti, Fe, Sr, Ba e Pb elements. (author)

  17. First combined total reflection X-ray fluorescence and grazing incidence X-ray absorption spectroscopy characterization of aeolian dust archived in Antarctica and Alpine deep ice cores

    International Nuclear Information System (INIS)

    Aeolian mineral dust archived in polar and mid latitude ice cores represents a precious proxy for assessing environmental and climatic variations at different timescales. In this respect, the identification of dust mineralogy plays a key role. In this work we performed the first preliminary X-ray absorption spectroscopy (XAS) experiments on mineral dust particles extracted from Antarctic and from Alpine firn cores using grazing incidence geometry at the Fe K-edge. A dedicated high vacuum experimental chamber was set up for normal-incidence and total-reflection X-Ray Fluorescence and Absorption Spectroscopy analyses on minor amounts of mineral materials at the Stanford Synchrotron Radiation Laboratory. Results show that this experimental technique and protocol allows recognizing iron inclusion mineral fraction on insoluble dust in the 1-10 μg range

  18. Portable ultrahigh-vacuum sample storage system for polarization-dependent total-reflection fluorescence x-ray absorption fine structure spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Yoshihide, E-mail: e0827@mosk.tytlabs.co.jp; Nishimura, Yusaku F.; Suzuki, Ryo; Beniya, Atsushi; Isomura, Noritake [Toyota Central R& D Labs., Inc., Yokomichi 41-1, Nagakute, Aichi 480-1192 (Japan); Uehara, Hiromitsu; Asakura, Kiyotaka; Takakusagi, Satoru [Catalysis Research Center, Hokkaido University, Kita 21-10, Sapporo, Hokkaido 001-0021 (Japan); Nimura, Tomoyuki [AVC Co., Ltd., Inada 1450-6, Hitachinaka, Ibaraki 312-0061 (Japan)

    2016-03-15

    A portable ultrahigh-vacuum sample storage system was designed and built to investigate the detailed geometric structures of mass-selected metal clusters on oxide substrates by polarization-dependent total-reflection fluorescence x-ray absorption fine structure spectroscopy (PTRF-XAFS). This ultrahigh-vacuum (UHV) sample storage system provides the handover of samples between two different sample manipulating systems. The sample storage system is adaptable for public transportation, facilitating experiments using air-sensitive samples in synchrotron radiation or other quantum beam facilities. The samples were transferred by the developed portable UHV transfer system via a public transportation at a distance over 400 km. The performance of the transfer system was demonstrated by a successful PTRF-XAFS study of Pt{sub 4} clusters deposited on a TiO{sub 2}(110) surface.

  19. Fermat's Principle in Curved Space-time, No Emission from Schwarzschild Black Holes as Total Internal Reflection and Black Hole Unruh effect

    CERN Document Server

    Mitra, Soma

    2015-01-01

    Using the Fermat's principle in curved space-time with stationary type metric, we have obtained the speed of light as a function of spatial coordinates and hence the corresponding refractive index. The whole region with space dependent gravity is divided into a number of overlapping transparent refracting media with varying refractive index. The refractive index is found to be increasing with the strength of gravitational field. Hence using the laws of refraction, we have explained the gravitational bending of light. Further using the conventional idea of total internal reflection of light while going from denser to rarer medium, in the present scenario it is the propagation of light from the region of ultra-strong gravitational field to relatively weaker gravitational field region, we have proposed an alternative approach for no emission of any kind of electromagnetic radiation from the surface of a classical Schwarzschild Black Hole. We have further noticed that for an observer in a uniformly accelerated fr...

  20. Multielement analysis of aerosols by means of neutron activation analysis and X-ray fluorescence analysis with totally reflecting sample holders

    International Nuclear Information System (INIS)

    For the analysis of aerosol samples on filters several methods for the energy dispersive X-ray Fluorescence Analysis with Totally Reflecting Sample Holder (TRXFA) with Mo-exitation were developed and investigated for systematic errors. The elements K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Br, Rb, Sr, Pb and Ba are detectable with high sensitivity. For the improved detection of short lifed nuclides (tsub(1/2) = 2 - 50 h) with the Neutron Activation Analysis (NAA) a radiochemical procedure for the separation of Na-24 and Br-82 was developed. The results of TRXFA and NAA correspond well. The capabilities of the developed methods were demonstrated on a set of size-fractionated aerosol samples. (orig.)

  1. Quantification of modifiers in advanced materials based on zinc oxide by total reflection X-ray fluorescence and inductively coupled plasma mass spectrometry

    Science.gov (United States)

    Filatova, Daria G.; Alov, Nikolai V.; Vorobyeva, Natalia A.; Rumyantseva, Marina N.; Sharanov, Pavel Yu.; Seregina, Irina F.; Gaskov, Alexander M.

    2016-04-01

    A novel approach to quantification of Ga and Zn modifiers in advanced materials based on zinc oxide is presented. The approach includes a combination of total reflection X-ray fluorescence (TXRF) and inductively coupled plasma mass spectrometry (ICP-MS) for determination and validation of the results. It is suggested to use aqueous standards for the direct determination of elements in powder samples by TXRF with a relative standard deviation no more than sr = 0.11. The accuracy of these results was proved by ICP-MS after the sample decomposition, sr(In) = 0.05, sr(Ga) = 0.06 and sr(Zn) = 0.06. It was established that there is a possibility to determine indium above 300 ppb on the background of K-M3 line of argon.

  2. Quantification of biomineralization: An in-vitro tissue culture system and microanalysis of calcium, phosphorus and trace elements by total-reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    An in-vitro tissue culture system with folded periostea of 17-day-old fetal chick calvaria was combined with analytical methods to achieve quantification of biomineralization. A scanning electron microscope with an energy-dispersive X-ray detector was applied to show the distribution of calcium, phosphorus and trace elements. Calcium and phosphorus were concentrated in the zone of the mineralized matrix. Strontium was distributed similar to calcium. Zinc was distributed equally in the soft tissue and the mineralized matrix. Total-reflection X-ray fluorescence was used for quantification. Thyroxine in high concentration reduces the calcium content of the samples. One week after incubation magnesium chloride (1.8 mM) or zinc chloride (.1 mM) were found to reduce the calcium content by 38% or 82%, respectively

  3. Portable ultrahigh-vacuum sample storage system for polarization-dependent total-reflection fluorescence x-ray absorption fine structure spectroscopy

    International Nuclear Information System (INIS)

    A portable ultrahigh-vacuum sample storage system was designed and built to investigate the detailed geometric structures of mass-selected metal clusters on oxide substrates by polarization-dependent total-reflection fluorescence x-ray absorption fine structure spectroscopy (PTRF-XAFS). This ultrahigh-vacuum (UHV) sample storage system provides the handover of samples between two different sample manipulating systems. The sample storage system is adaptable for public transportation, facilitating experiments using air-sensitive samples in synchrotron radiation or other quantum beam facilities. The samples were transferred by the developed portable UHV transfer system via a public transportation at a distance over 400 km. The performance of the transfer system was demonstrated by a successful PTRF-XAFS study of Pt4 clusters deposited on a TiO2(110) surface

  4. Making use of x-ray optical effects in photoelectron-, Auger electron-, and x-ray emission spectroscopies: Total reflection, standing-wave excitation, and resonant effects

    International Nuclear Information System (INIS)

    We present a general theoretical methodology and related open-access computer program for carrying out the calculation of photoelectron, Auger electron, and x-ray emission intensities in the presence of several x-ray optical effects, including total reflection at grazing incidence, excitation with standing-waves produced by reflection from synthetic multilayers and at core-level resonance conditions, and the use of variable polarization to produce magnetic circular dichroism. Calculations illustrating all of these effects are presented, including in some cases comparisons to experimental results. Sample types include both semi-infinite flat surfaces and arbitrary multilayer configurations, with interdiffusion/roughness at their interfaces. These x-ray optical effects can significantly alter observed photoelectron, Auger, and x-ray intensities, and in fact lead to several generally useful techniques for enhancing surface and buried-layer sensitivity, including layer-resolved densities of states and depth profiles of element-specific magnetization. The computer program used in this study should thus be useful for a broad range of studies in which x-ray optical effects are involved or are to be exploited in next-generation surface and interface studies of nanoscale systems.

  5. Total reflection X-ray fluorescence and energy-dispersive X-ray fluorescence analysis of runoff water and vegetation from abandoned mining of Pb-Zn ores

    International Nuclear Information System (INIS)

    The present work reports on the heavy metal content: Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Cd and Pb in running waters and vegetation around abandoned mining areas. Two species of mosses (Dicranum sp. and Pleurocarpus sp.) and three different species of wild grass (Bromus sp., Rumex sp. and Pseudoavena sp.) growing on the surrounding areas of old lead-zinc mines (Aran Valley, Pyrenees, NE Spain) have been analyzed. Both water and vegetation were collected in two different sampling places: (a) near the mine gallery water outlets and (b) on the landfill close to the abandoned mineral concentration factories. For the heavy metal content determination, two different techniques were used: total reflection X-ray fluorescence for water analysis and energy-dispersive X-ray fluorescence for vegetation study. Surface waters around mine outlets exhibit anomalous content of Co, Ni, Zn, Cd. Stream waters running on mining landfills exhibit higher Cu, Zn, Cd and Pb than those of the waters at the mine gallery outlets. The results allow us to assess the extent of the environmental impact of the mining activities on the water quality. The intake of these elements by vegetation was related with the sampling place, reflecting the metal water content and the substrate chemistry. Accumulation of metals in mosses is higher than those exhibited in wild grasses. Furthermore, different levels of accumulation were found in different wild grass. Rumex sp. presented the lowest metal concentrations, while Pseudoavena sp. reported the highest metal content

  6. Total reflection X-ray fluorescence and energy-dispersive X-ray fluorescence analysis of runoff water and vegetation from abandoned mining of Pb Zn ores

    Science.gov (United States)

    Marques, A. F.; Queralt, I.; Carvalho, M. L.; Bordalo, M.

    2003-12-01

    The present work reports on the heavy metal content: Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Cd and Pb in running waters and vegetation around abandoned mining areas. Two species of mosses ( Dicranum sp. and Pleurocarpus sp.) and three different species of wild grass ( Bromus sp., Rumex sp. and Pseudoavena sp.) growing on the surrounding areas of old lead-zinc mines (Aran Valley, Pyrenees, NE Spain) have been analyzed. Both water and vegetation were collected in two different sampling places: (a) near the mine gallery water outlets and (b) on the landfill close to the abandoned mineral concentration factories. For the heavy metal content determination, two different techniques were used: total reflection X-ray fluorescence for water analysis and energy-dispersive X-ray fluorescence for vegetation study. Surface waters around mine outlets exhibit anomalous content of Co, Ni, Zn, Cd. Stream waters running on mining landfills exhibit higher Cu, Zn, Cd and Pb than those of the waters at the mine gallery outlets. The results allow us to assess the extent of the environmental impact of the mining activities on the water quality. The intake of these elements by vegetation was related with the sampling place, reflecting the metal water content and the substrate chemistry. Accumulation of metals in mosses is higher than those exhibited in wild grasses. Furthermore, different levels of accumulation were found in different wild grass. Rumex sp. presented the lowest metal concentrations, while Pseudoavena sp. reported the highest metal content.

  7. Total internal reflection without change of polarization using a right-angle prism with half-wavelength-thick optical interference coating.

    Science.gov (United States)

    Azzam, R M A

    2009-02-01

    Monochromatic light, which is polarized in an arbitrary state, is totally internally reflected at angle of incidence phi=45 degrees without change of polarization by a right-angle prism of refractive index n0=1+1/Square root of 2=1.70711 (e.g., N-LAK8 Schott glass at wavelength lambda=706 nm), which is coated with a transparent thin film of refractive index n1=(1+1/2)1/2=1.30656 (e.g., vacuum-deposited fluoride material) and of metric thickness equal to half of the vacuum wavelength of incident light, d=lambda/2. The ambient medium of evanescent refraction is assumed to be vacuum, air, or an inert gas. Wavelength shifts of +/-50 nm, or changes of the internal angle of incidence of +/-1 degrees around 45 degrees, cause phase errors of only a few degrees. The reflected and incident polarization states are nearly identical in the presence of such small phase errors. PMID:19183662

  8. Room temperature trapping of stibine and bismuthine onto quartz substrates coated with nanostructured palladium for total reflection X-ray fluorescence analysis

    Energy Technology Data Exchange (ETDEWEB)

    Romero, Vanesa; Costas-Mora, Isabel; Lavilla, Isela; Bendicho, Carlos, E-mail: bendicho@uvigo.es

    2015-05-01

    In this work, a novel method for determining Sb and Bi based on the trapping of their covalent hydrides onto quartz reflectors coated with immobilized palladium nanoparticles (Pd NPs) followed by total reflection X-ray fluorescence (TXRF) analysis is proposed. Pd NPs were synthesized by chemical reduction of the metal precursor using a mixture of water:ethanol as mild reducing agent. Silanization using 3-mercaptopropyltrimethoxysilane (MPTMS) was performed for the immobilization of Pd NPs onto the quartz substrates. Volatile hydrides (stibine and bismuthine) generated by means of a continuous flow system were flushed onto the immobilized Pd NPs and retained by catalytic decomposition. As a result of the high catalytic activity of the nanostructured film, trapping can be performed at ambient temperature with good efficiency. Limits of detection (LODs) were 2.3 and 0.70 μg L{sup −1} for Sb and Bi, respectively. Enrichment factors of 534 and 192 were obtained for Sb and Bi, respectively. The new method was applied for the analysis of several matrices (milk, soil, sediment, cutaneous powder). Recoveries were in the range of 98.4–101% for both elements with a relative standard deviation of 2.5% (N = 5). - Highlights: • A novel method for trapping covalent hydrides of antimony and bismuth is proposed. • Emphasis is placed on the application of Pd nanoparticles as trapping surface. • The nanostructured surface provides high catalytic activity at ambient temperature. • Analysis by total reflection X-ray fluorescence is performed. • Determination of Bi and Sb in different matrices is carried out.

  9. Attenuation of the Disruptive Effect induced by the Insecticide Fenvalerate on Total Monoamine Content and Testosterone Level in Adult Male Albino Rats Using Salvia aegyptiaca Extract

    International Nuclear Information System (INIS)

    Administration of fenvalerate (90 mg/kg) to rats resulted in a significant decrease in dopamine (OA) content in most of brain areas under investigation. Its content in pons + medulla oblongata was the most affected recording - 62.98 %, on day 7, compared to control. Furthermore, norepinephrine (NE) content gradually decreased in different brain areas showing its maximal decrease in cerebellum with percentage change -64.89% on day 7. Serotonin (5-HT) and its metabolite 5-hydroxyindoleacetic acid (5-HIAA) showed maximal significant decrease, in the cortex with percentage differences -78.33 and -72.61%, respectively. Similarly, fen valerate resulted in a gradual decrease in serum testosterone level recording its maximal effect (-46. 58 %) at the end of the experimental period. On the other hand, administration of Salvia aegyptiaca (2 g/kg) caused a significant increase in monoamine contents (DA, NE, 5-HT and 5- HlAA) in most of the brain areas under investigation, throughout the experimental period. Moreover, Salvia extract administration resulted in a significant elevation in serum testosterone level, one day after administration, recording its maximal effect (55.75%) on day 7. Animals that received the combined treatment (Salvia extract one hour after fen valerate administration) showed that monoamine contents in most of the brain areas were more or less near to the control values. Furthermore, no significant change was noticed in serum testosterone level throughout the experiment in the combined treatment. From the present study, it can be concluded that Salvia aegyptiaca extract seems to be potentially promising for attenuating the disruption that occurred in monoamine and testosterone levels. This could highly recommend Salvia aegyptiaca to be a potential herb for further studies in the future for extracting compounds of medical use

  10. Determination of Proteins by Measuring Total Internal-reflected Resonance Light Scattering Signals on Water/Tetrachloromethane Interface with Evans Blue and Cetyltrimethylammonium Bromide

    Institute of Scientific and Technical Information of China (English)

    HUANG Cheng-zhi; FENG Ping; LI Yuan-fang; ZHAO Hua-wen

    2005-01-01

    A sensitive and selective assay of proteins is proposed based on measuring the total internal-reflected resonance light scattering(TIR-RLS) signals produced on the water/tetrachloromethane(H2O/CCl4) interface. In an aqueous medium with pH value in the range of 3.29-3.78, electrostatic attraction occurs between the negatively charged Evans Blue(EB) and positively charged proteins, forming hydrophobic ion associates and resulting in EB-protein adsorption on H2O/CCl4 interface. The presence of cetyltrimethylammonium bromide prompts this adsorption, resulting in strongly enhanced TIR-RLS signals. The intensity of the enhanced TIR-RLS at 360-370 nm was found to be proportional to the concentration of proteins. For bovine serum albumin and human serum albumin, the linear range of detection is 0.07-1.2 μg/mL and the limits of detection are 6.68 and 6.30 ng/mL(3σ), respectively, while for lysozyme, the linear range of detection is 0.06-1.0 μg/mL and the limit of detection is 6.0 ng/mL(3σ). The content of the total albumin in a human urine sample could be directly determined by using the standard addition method with a percent recovery of 97.6%-104.1%, and the RSD ranging from 1.9% to 4.2%.

  11. Is there seismic attenuation in the mantle?

    Science.gov (United States)

    Ricard, Y.; Durand, S.; Montagner, J.-P.; Chambat, F.

    2014-02-01

    The small scale heterogeneity of the mantle is mostly due to the mixing of petrological heterogeneities by a smooth but chaotic convection and should consist in a laminated structure (marble cake) with a power spectrum S(k) varying as 1/k, where k is the wavenumber of the anomalies. This distribution of heterogeneities during convective stirring with negligible diffusion, called Batchelor regime is documented by fluid dynamic experiments and corresponds to what can be inferred from geochemistry and seismic tomography. This laminated structure imposes density, seismic velocity and potentially, anisotropic heterogeneities with similar 1/k spectra. A seismic wave of wavenumber k0 crossing such a medium is partly reflected by the heterogeneities and we show that the scattered energy is proportional to k0S(2k0). The reduction of energy for the propagating wave appears therefore equivalent to a quality factor 1/Q∝k0S(2k0). With the specific 1/k spectrum of the mantle, the resulting apparent attenuation should therefore be frequency independent. We show that the total contribution of 6-9% RMS density, velocity and anisotropy would explain the observed S and P attenuation of the mantle. Although these values are large, they are not unreasonable and we discuss how they depend on the range of frequencies over which the attenuation is explained. If such a level of heterogeneity were present, most of the attenuation of the Earth would be due to small scale scattering by laminations, not by intrinsic dissipation. Intrinsic dissipation must certainly exist but might correspond to a larger, yet unobserved Q. This provocative result would explain the very weak frequency dependence of the attenuation, and the fact that bulk attenuation seems negligible, two observations that have been difficult to explain for 50 years.

  12. Precision Model for Microwave Rotary Vane Attenuator

    DEFF Research Database (Denmark)

    Guldbrandsen, Tom

    1979-01-01

    A model for a rotary vane attenuator is developed to describe the attenuator reflection and transmission coefficients in detail. All the parameters of the model can be measured in situ, i.e., without diassembling any part. The tranmission errors caused by internal reflections are calculated from...

  13. Attenuation Correction of Reflectivity for X-Band Dual-Polarization Radar%X波段双线偏振气象雷达反射率的衰减订正

    Institute of Scientific and Technical Information of China (English)

    毕永恒; 刘锦丽; 段树; 吕达仁; 苏德斌; 陈羿辰

    2012-01-01

    X波段天气雷达的强衰减是影响其探测精度与应用推广的主要问题.本文旨在寻求适用于降水过程中对X波段双偏振雷达进行衰减订正的一种方法.在订正前先对雷达数据进行了质量控制和预处理;在分析了国内外已有订正方法的基础上,选择并改进了自适应约束算法作为雷达反射率进行衰减订正的方法;最后进行方法的效果验证.既对衰减订正前后反射率与同时段S波段雷达反射率作对比,又对偏振参数KDP~ZH、AH~ZH之间关系的变化进行分析,不仅如此,还直接与地面降水实况作比较等.分析表明,对X波段双线偏振雷达进行反射率衰减订正后的效果显著优于订正前,特别是,当存在较大范围(含对流型)降雨时,采用此种订正方法可以明显提高降水的估测精度.%Strong attenuation in rain affects the detection accuracy and application of the X-band radar. This paper aims to seek a method of attenuation correction for X-band dual-polarization radar in precipitation. Before correction, the radar data are pre-processed with quality controls after analyzing all the methods from the past works, an attenuation correction algorithm is developed which is based on the self-consistent method with constraints; finally some validation methods are studied. Some comparisons are made between the corrected composite reflectivity of the X-band radar and a nearby S-band radar observed at the same time; moreover, the corrected relationships between KDP vs. Zh and Ah vs. Zh are also similar to the theoretical values predicted by scattering simulation. In addition, the authors also compare the corrected reflectivity with the surface rain-gauge observations. The analysis results indicate that the corrected reflectivity is more significant than the uncorrected one; specially for the larger area of rainfall (including convective rainfall) using the above attenuation correction algorithm for X-band radar

  14. Application of total-reflection X-ray fluorescence spectrometry and high-performance liquid chromatography for the chemical characterization of xylem saps of nickel contaminated cucumber plants

    Science.gov (United States)

    Mihucz, Victor G.; Tatár, Eniko; Varga, Anita; Záray, Gyula; Cseh, Edit

    2001-11-01

    Total-reflection X-ray fluorescence (TXRF) spectrometry, reversed-phase (RP) and size-exclusion (SE) high-performance liquid chromatography (HPLC) methods were applied for the characterization of low-volume xylem sap of control and nickel contaminated cucumber plants growing in hydroponics containing urea as the sole nitrogen source. In these saps collected for 1 h, Ca, K, Fe, Mn, Ni, Zn, as well as malic, citric and fumaric acids were determined. The SEC measurements showed that macromolecules were not detectable in the samples. Nickel contamination had minimum impact on the organic acid transport, however, the transport of Zn, K and Fe was reduced by 50, 22 and 11%, respectively. This observation supports the results of our earlier experiments when nitrate ions were used as the sole nitrogen form. At the same time, the fresh root weight and the volume of the collected xylem sap increased by 36 and 85%, respectively. Therefore, nickel addition seemed to decrease the urea toxicity of the plants. By pooling the eluting fractions of the SEC column, which were 10-fold concentrated by freeze-drying, the series of the resulted samples were analyzed by the TXRF spectrometry and RP-HPLC. The three organic acids could be identified in only one of the fractions, which contained Fe and, in the case of the contaminated plants, Ni in detectable concentration. However, considerable parts of these two elements and Mn, as well as practically the total amounts of Cu may be transported by unidentified organic compounds in the xylem.

  15. Use of total reflection X-ray fluorescence to determine micro- and macroelements in the plasma of animals parasitized by Tripanossoma cruzi

    International Nuclear Information System (INIS)

    The mineral levels of S, Cl, K, Ca, Cr, Fe, Cu, and Zn in the plasma of mice (line BALB/c) infected with strains Bolivia and Y of Trypanosoma cruzi were determined by Total Reflection X-Ray Fluorescence technique (TXRF), with concentration raging from 0.2 (Cu) to 2650 (S) μg/g. Three experimental groups were used: a control group, a group of infected females, and a group of infected males. The plasma of the animals was obtained before, during, and after the parasitemic peak for each of the three groups and for each strain used. Sample excitation was performed using an X-ray tube with a Mo target and Zr filter, operating at 40 kV and 30 mA, at an incidence angle of 6.4 min. In general, the elements evaluated showed small variations between the different groups, without statistical difference. Significant alterations were observed in the Bolivia strain, demonstrating that a relation between this strain and changes in the levels determined for the elements might exist. (author)

  16. Three empirical cases of the deposition morphology influence in the analytical quality of direct solid suspension measurements by total-reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    This work describes three empirical cases where the influence of the microscopic and macroscopic morphology of the sample depositions analyzed by total-reflection X-ray fluorescence with respect to the accuracy and uncertainties of its analytical results is shown. The first case was the direct solid analysis of reference clay, where a strong dependence between the accuracy and the uncertainty of the evaluated elements with respect to the microscopic morphology of the depositions obtained in water and toluene liquid medium was observed. The second case was the analysis of a solid suspension of magnetite nanoparticles, where the evaluation of the different macroscopic deposition morphologies, for different kinds of sample carriers and evaporation processes, produces an important variation of the uncertainty associated to the Fe measurements but not for its nominal values. Finally, the third case was the analysis of Ru and Se impregnated in carbon nanoparticles. In this case, the ultrasonic modifications of the particle size distributions in the solid suspensions, together with the macroscopic morphology variation of its solid depositions, produce drastic consequences in the uncertainties associated with the metallic content.

  17. Total internal reflection plasmonic scattering-based fluorescence-free nanoimmunosensor probe for ultra-sensitive detection of cancer antigen 125.

    Science.gov (United States)

    Chakkarapani, Suresh Kumar; Zhang, Peng; Ahn, Sujin; Kang, Seong Ho

    2016-07-15

    Highly sensitive detection of cancer antigen 125 (CA125) on nanoarray chips was carried out by means of total internal reflection (TIR) microscopy based on fluorescent labeling (i.e., TIR fluorescence microscopy; TIRFM) and fluorescent-free labeling (TIR scattering microscopy; TIRSM). TIR plasmonic scattering of nanoparticles (NPs) as a fluorescence-free immunosensor probe potentially superior to fluorescent probes was applied to quantify CA125 on a nanoarray chip. NP-labeled CA125 (NP-CA125) was immunoreacted on chips, and the TIR scattering illumination of NP-CA125 allowed quantitative TIRSM measurement of wavelength-dependent plasmonic scattering detection of CA125. In addition, Alexafluor 488-labeled CA125 was immunoreacted on the same chips for comparison of detection sensitivity. TIRSM showed less photobleaching and higher photostability and detection sensitivity than TIRFM, as well as a lower limit of detection (LOD), 0.0018U/mL. This LOD was ~144 times lower than that of previously reported detection methods. These results demonstrated that the wavelength-dependent TIR plasmon NPs can be used as an enhanced nanoimmunosensor probe, providing ultra-sensitive fluorescence-free biomolecule detection to enable earliest-stage disease diagnosis. PMID:26913504

  18. Iron speciation in human cancer cells by K-edge total reflection X-ray fluorescence-X-ray absorption near edge structure analysis

    Science.gov (United States)

    Polgári, Zs.; Meirer, F.; Sasamori, S.; Ingerle, D.; Pepponi, G.; Streli, C.; Rickers, K.; Réti, A.; Budai, B.; Szoboszlai, N.; Záray, G.

    2011-03-01

    X-ray absorption near edge structure (XANES) analysis in combination with synchrotron radiation induced total reflection X-ray fluorescence (SR-TXRF) acquisition was used to determine the oxidation state of Fe in human cancer cells and simultaneously their elemental composition by applying a simple sample preparation procedure consisting of pipetting the cell suspension onto the quartz reflectors. XANES spectra of several inorganic and organic iron compounds were recorded and compared to that of different cell lines. The XANES spectra of cells, independently from the phase of cell growth and cell type were very similar to that of ferritin, the main Fe store within the cell. The spectra obtained after CoCl 2 or NiCl 2 treatment, which could mimic a hypoxic state of cells, did not differ noticeably from that of the ferritin standard. After 5-fluorouracil administration, which could also induce an oxidative-stress in cells, the absorption edge position was shifted toward higher energies representing a higher oxidation state of Fe. Intense treatment with antimycin A, which inhibits electron transfer in the respiratory chain, resulted in minor changes in the spectrum, resembling rather the N-donor Fe-α,α'-dipyridyl complex at the oxidation energy of Fe(III), than ferritin. The incorporation of Co and Ni in the cells was followed by SR-TXRF measurements.

  19. Total reflection X-ray fluorescence measurements of S and P in proteins using a vacuum chamber specially designed for low Z elements

    International Nuclear Information System (INIS)

    As the ratio of phosphorus and sulfur in proteins allows the determination of the phosphorylation degree in proteins, the absolute determination of phosphorus and sulfur in organic samples is of growing interest. While it takes some effort to quantify phosphorus and sulfur with inductively coupled quadrupole plasma mass spectrometry (ICP-QMS), total reflection X-ray fluorescence analysis (TXRF) allows easy quantification. In the presented work, the low Z TXRF spectrometer at the Atominstitut was used to analyze phosphorus and sulfur in proteins. Although the preparation of the protein samples proved to be more difficult than originally expected, it could be shown that TXRF is well suited for the determination of P and S in proteins. The obtained lower limits of detection (LLD) for P and S in proteins were extrapolated for 1000s and were 34 pg and 19 pg, respectively. The importance of height scans for each sample to exclude heterogeneities was demonstrated. - Highlights: • Low Z TXRF spectrometry was used to analyze phosphorus and sulfur in proteins. • TXRF is well suited for the determination of P and S in proteins. • Good detection limits for P (34 pg) and S (19 pg) were achieved. • Due to the detection limits, we propose that TXRF is a suitable method to analyze protein fractions

  20. Characterization by Total Reflection X-ray Fluorescence Spectrometry of filtered water into the cave under the Sun Pyramid in Teotihuacan City

    International Nuclear Information System (INIS)

    Teotihuacan (50 km north-east Mexico City) was the most important ancient city in Mesoamerica and it flourished 200-750 AC. It is situated in the central part of the Valley of Teotihuacan, in Central Mexico. This study was carried out in the 102 m-long cave under the largest single construction, the massive Sun Pyramid, being located on the east side of the 'Avenue of the Dead', in the northern half-part of the city. The study shows the results of Total Reflection X-ray Fluorescence Spectrometry analysis and other techniques of a water sample obtained from the inside of the cave. The inside temperature ranged between 19 and 22 deg. C; relative humidity was between 98 and 99.3%; water-dropping velocity (water de-sorption capability) was 13.5 μL min-1. Water samples from wells around the site were analyzed too. Metal concentration in all of the water samples matches the characteristics of the sampling site, well's depth, soil and minerals

  1. Quantification of potentially toxic elements in sewage and sludge from treatment plants in the cities of Campinas and Jaguariuna using synchrotron radiation total reflection X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Luciana Carla Ferreira de; Canteras, Felippe Benavente; Moreira, Silvana, E-mail: silvana@fec.unicamp.br, E-mail: felippe.canteras@gmail.com, E-mail: lucarla24@gmail.com [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil). Inst. Politecnico. Dept. de Saneamento e Ambiente

    2013-07-01

    The rapid urban and industrial development in last decades has brought as one of the consequences, changes in the environment. The lack of planning of city growth is, today, one of the major causes of water pollution including residential, industrial, agricultural, and hospital waste. The metals contamination is a major problem, causing serious changes to the environment, causing harm to human health. The sludge generated at sewage treatment plants, is an important source of nutrients and organic matter, and therefore it can also be reused mainly for agricultural use, since contaminants are removed. The cities of Campinas and Jaguariuna are inserted in the Campinas Metropolitan Region (CMR), one of the most dynamic regions in the Brazilian economy. Therefore, to study the anthropogenic influences of the cities, evaluated the quality of raw and treated effluent and the sludge generated in sewage treatment plants, especially with regard to heavy metals. Measurements of metals were performed by Synchrotron Radiation Total Reflection X-ray Fluorescence. For treated effluent data were compared to CONAMA 357 law and Cr, Mn, Fe, Ni, Cu, Zn, Ba and Pb showed concentrations in according with the law. To reuse in agriculture the contents were compared to the limits defined by CETESB and some elements had concentrations above to the permitted preventing its reuse. For sludge, Cr, Ni, Cu, Zn, Ba and Pb, in the two treatment plants studied, the concentrations were lower than the maximum permissible values established by CONAMA 375 law allowing the sludge application sludge on agricultural land. (author)

  2. Characterization of high-k gate dielectric and metal gate electrode semiconductor samples with a total reflection X-ray fluorescence spectrometer

    International Nuclear Information System (INIS)

    The versatility of a total reflection X-ray fluorescence (TXRF) spectrometer in the analysis of semiconductor samples will be demonstrated. While TXRF has a well-established place in trace metals analysis on silicon wafers, the practice of characterizing new films with TXRF is not routine in the semiconductor industry. In this paper, we will examine the monitoring of high-k film growth on silicon wafers by TXRF. We will show that a linear relationship between cycles of film deposition and TXRF signal is possible with proper analytical conditions. This signal can be converted to film thickness by normalizing to cross-sectional measurement from transmission electron microscopy (TEM). Information about the interface between the deposited high-k layer and the silicon substrate can also be determined from TXRF data. Secondary ion mass spectrometry data of a chlorine species at the interface of the high-k and silicon were collaborated with TXRF data. Critical angle measurements were taken on ruthenium and ruthenium dioxide films to extract physical characteristics and these results were compared to those from other techniques

  3. Elemental changes in hemolymph and urine of Rhodnius prolixus induced by in-vivo exposure to mercury: A study using synchrotron radiation total reflection X-ray fluorescence

    Science.gov (United States)

    Mantuano, Andrea; Pickler, Arissa; Barroso, Regina C.; de Almeida, André P.; Braz, Delson; Cardoso, Simone C.; Gonzalez, Marcelo S.; Figueiredo, Marcela B.; Garcia, Eloi S.; Azambuja, Patricia

    2012-05-01

    In recent years, the effects of pollution on the health of humans and other vertebrates were extensively studied. However, the effects on some invertebrates are comparatively unknown. Recent studies have demonstrated that toxic metals interfere with the reproduction, development and immune defenses of some terrestrial and marine invertebrates. Some environmental conditions including pollution produce chronic and acute effects on different animal's organs and systems. In this work, we investigated changes in the concentrations of Cl, K, Ca, Fe and Zn in Rhodnius prolixus as insect model. The elements were quantified using urine and hemolymph samples collected on different days after feeding the insects with blood containing HgCl2. The synchrotron radiation total reflection X-ray fluorescence measurements were carried at the X-ray fluorescence beamline facility in Brazilian Synchrotron Light Laboratory. The observation reveals that the calcium level was higher in the hemolymph than in urine. On the other hand, the urine collected from insects treated with HgCl2 showed higher level of Cl than hemolymph samples. Ca, Fe and Zn concentrations decrease drastically in urine samples collected after 2 days of HgCl2 treatment. The regulation of triatomines excretion was discussed pointing out the importance of trace elements.

  4. Polarized total-reflection x-ray absorption fine structure for self-assembled monolayer of zinc porphyrin at air-water interface

    International Nuclear Information System (INIS)

    A new x-ray absorption fine structure (XAFS) method is applied to the air-solution interface. Under the total reflection condition, the XAFS method becomes surface sensitive, enabling the self-assembled monolayer of a metal complex at the solution surface to analyze in situ. Furthermore the introduction of two types of linearly polarized x rays allows us to determine the selective orientation of a planar metal complex at the surface. We obtain spectra for a square planar complex, 5,10,15,20-tetrakis(4-carboxyphenyl)porphyrinato zinc(II) (ZnTPPC) adsorbed on the aqueous solution surface forming a monolayer with two polarized x rays and compared them with spectra of the same compound in a bulk solution and in solid powder. The polarized XAFS spectra exhibit different features leading to the unambiguous conclusion that the plane of the ZnTPPC molecule is oriented parallel to the air-water interface and that there is no coordination to the axial sites of the zinc atom

  5. Elemental concentration analysis in brain of young, adult and old wistar rats by X-ray total reflection fluorescence with synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Serpa, Renata F.B.; Jesus, Edgar F.O. de; Lopes, Ricardo T. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Lab. de Instrumentacao Nuclear]. E-mail: renata@lin.ufrj.br; Anjos, Marcelino J. dos [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Inst. de Fisica]. E-mail: marcelin@lin.ufrj.br; Carmo, Maria da Graca T. do [Universidade Federal, Rio de Janeiro, RJ (Brazil). Inst. de Nutricao]. E-mail: tcarmo@editema.com.br; Rocha, Monica S. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Dept. de Farmacologia]. E-mail: mrocha@farmaco.ufrj.br; Moreira, Silvana [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Civil]. E-mail: silvana@fec.unicamp.br; Martinez, Ana Maria B. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Dept. de Histologia]. E-mail: martinez@histo.ufrj.br

    2005-07-01

    The mainly goal of this work is to compare the elemental concentrations with different postnatal ages (2, 8, 20, 48 and 72 weeks) at three different regions of the rat brain, namely temporal cortex, entorhinal cortex and hippocampus by X-Ray Total Reflection Fluorescence with Synchrotron Radiation (SR-TXRF). The advantages for this analytical multielemental technique are: low background, linear relation in the quantification analysis and low detection limit (ngg{sup -1}). The fluorescence measurements were carried out at XRF beamline at the Brazilian Light Synchrotron Laboratory (Campinas, Brazil). It was possible to determine the following elements: Ti, Mn, Fe, Cu, Zn, Br, Rb and Sr (at trace level) and P, S, Cl, K and Ca (at major levels) were determined in the brain. In general, Fe levels were more pronounced in entorhinal cortex. There was also observed that the hippocampus of the old female rat presented the highest concentrations for Al, P, S, K, and Zn. In contrast to this, the hippocampus and entorhinal cortex presented the less levels for Al and K in the young animals. On the other hand, Cl levels were more conspicuous in the entorhinal cortex of the oldest male animal studied. (author)

  6. Determination of calcium, potassium, manganese, iron, copper and zinc levels in representative samples of two onion cultivars using total reflection X-ray fluorescence and ultrasound extraction procedure

    International Nuclear Information System (INIS)

    The chemical characterization of onion cultivar samples is an important tool for the enhancement of their productivity due to the fact that chemical composition is closed related to the quality of the products. A new sample preparation procedure for elemental characterization is proposed, involving the acid extraction of the analytes from crude samples by means of an ultrasonic bath, avoiding the required digestion of samples in vegetable tissue analysis. The technique of total reflection X-ray fluorescence (TXRF) was successfully applied for the simultaneous determination of the elements Ca, K, Mn, Fe, Cu and Zn. The procedure was compared with the wet ashing and dry ashing procedures for all the elements using multivariate analysis and the Scheffe test. The technique of flame atomic absorption spectrometry (FAAS) was employed for comparison purposes and accuracy evaluation of the proposed analysis method. A good agreement between the two techniques was found when using the dry ashing and ultrasound leaching procedures. The levels of each element found for representative samples of two onion cultivars (Yellow Granex PRR 502 and 438 Granex) were also compared by the same method. Levels of K, Mn and Zn were significantly higher in the 438 Granex cultivar, while levels of Ca, Fe and Cu were significantly higher in the Yellow Granex PRR 502 cultivar

  7. Total reflection X-ray fluorescence measurements of S and P in proteins using a vacuum chamber specially designed for low Z elements

    Energy Technology Data Exchange (ETDEWEB)

    Rauwolf, M., E-mail: mrauwolf@ati.ac.at [Atominstitut, Technische Universität Wien, Stadionallee 2, Vienna 1020 (Austria); Vanhoof, C.; Tirez, K.; Maes, E. [Flemish Institute for Technological Research NV, Boeretang 200, Mol 2400 (Belgium); Ingerle, D.; Wobrauschek, P.; Streli, C. [Atominstitut, Technische Universität Wien, Stadionallee 2, Vienna 1020 (Austria)

    2014-11-01

    As the ratio of phosphorus and sulfur in proteins allows the determination of the phosphorylation degree in proteins, the absolute determination of phosphorus and sulfur in organic samples is of growing interest. While it takes some effort to quantify phosphorus and sulfur with inductively coupled quadrupole plasma mass spectrometry (ICP-QMS), total reflection X-ray fluorescence analysis (TXRF) allows easy quantification. In the presented work, the low Z TXRF spectrometer at the Atominstitut was used to analyze phosphorus and sulfur in proteins. Although the preparation of the protein samples proved to be more difficult than originally expected, it could be shown that TXRF is well suited for the determination of P and S in proteins. The obtained lower limits of detection (LLD) for P and S in proteins were extrapolated for 1000s and were 34 pg and 19 pg, respectively. The importance of height scans for each sample to exclude heterogeneities was demonstrated. - Highlights: • Low Z TXRF spectrometry was used to analyze phosphorus and sulfur in proteins. • TXRF is well suited for the determination of P and S in proteins. • Good detection limits for P (34 pg) and S (19 pg) were achieved. • Due to the detection limits, we propose that TXRF is a suitable method to analyze protein fractions.

  8. Characterization by Total Reflection X-ray Fluorescence Spectrometry of filtered water into the cave under the Sun Pyramid in Teotihuacan City

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, T. [National University of Mexico, Faculty of Chemistry, Building D, CU, O4510, Mexico, D.F. (Mexico)], E-mail: tmc@servidor.unam.mx; Zarazua, G.; Avila-Perez, P. [National Institute of Nuclear Research, Carr. Mexico-Toluca Km 36.5, 52045, Salazar, Ocoyoacac, Edo. de Mexico (Mexico); Juarez, F. [National University of Mexico, Institute of Geophysics, Circuito Institutos, CU, 04510 Mexico, D.F. (Mexico); Cabrera, L. [National University of Mexico, Faculty of Chemistry, Building D, CU, O4510, Mexico, D.F. (Mexico); Martinez, G. [Coordinacion Nacional de Conservacion del Patrimonio Cultural, Xicotencatl y General Anaya s/n., 04120, Mexico, D.F. (Mexico)

    2008-12-15

    Teotihuacan (50 km north-east Mexico City) was the most important ancient city in Mesoamerica and it flourished 200-750 AC. It is situated in the central part of the Valley of Teotihuacan, in Central Mexico. This study was carried out in the 102 m-long cave under the largest single construction, the massive Sun Pyramid, being located on the east side of the 'Avenue of the Dead', in the northern half-part of the city. The study shows the results of Total Reflection X-ray Fluorescence Spectrometry analysis and other techniques of a water sample obtained from the inside of the cave. The inside temperature ranged between 19 and 22 deg. C; relative humidity was between 98 and 99.3%; water-dropping velocity (water de-sorption capability) was 13.5 {mu}L min{sup -1}. Water samples from wells around the site were analyzed too. Metal concentration in all of the water samples matches the characteristics of the sampling site, well's depth, soil and minerals.

  9. Characterization by Total Reflection X-ray Fluorescence Spectrometry of filtered water into the cave under the Sun Pyramid in Teotihuacan City

    Science.gov (United States)

    Martinez, T.; Zarazua, G.; Avila-Perez, P.; Juarez, F.; Cabrera, L.; Martinez, G.

    2008-12-01

    Teotihuacan (50 km north-east Mexico City) was the most important ancient city in Mesoamerica and it flourished 200-750 AC. It is situated in the central part of the Valley of Teotihuacan, in Central México. This study was carried out in the 102 m-long cave under the largest single construction, the massive Sun Pyramid, being located on the east side of the "Avenue of the Dead", in the northern half-part of the city. The study shows the results of Total Reflection X-ray Fluorescence Spectrometry analysis and other techniques of a water sample obtained from the inside of the cave. The inside temperature ranged between 19 and 22 °C; relative humidity was between 98 and 99.3%; water-dropping velocity (water de-sorption capability) was 13.5 μL min - 1 . Water samples from wells around the site were analyzed too. Metal concentration in all of the water samples matches the characteristics of the sampling site, well's depth, soil and minerals.

  10. Iron speciation in human cancer cells by K-edge total reflection X-ray fluorescence-X-ray absorption near edge structure analysis

    International Nuclear Information System (INIS)

    X-ray absorption near edge structure (XANES) analysis in combination with synchrotron radiation induced total reflection X-ray fluorescence (SR-TXRF) acquisition was used to determine the oxidation state of Fe in human cancer cells and simultaneously their elemental composition by applying a simple sample preparation procedure consisting of pipetting the cell suspension onto the quartz reflectors. XANES spectra of several inorganic and organic iron compounds were recorded and compared to that of different cell lines. The XANES spectra of cells, independently from the phase of cell growth and cell type were very similar to that of ferritin, the main Fe store within the cell. The spectra obtained after CoCl2 or NiCl2 treatment, which could mimic a hypoxic state of cells, did not differ noticeably from that of the ferritin standard. After 5-fluorouracil administration, which could also induce an oxidative-stress in cells, the absorption edge position was shifted toward higher energies representing a higher oxidation state of Fe. Intense treatment with antimycin A, which inhibits electron transfer in the respiratory chain, resulted in minor changes in the spectrum, resembling rather the N-donor Fe-α,α'-dipyridyl complex at the oxidation energy of Fe(III), than ferritin. The incorporation of Co and Ni in the cells was followed by SR-TXRF measurements.

  11. North Sea research projects ZISCH and PRISMA: application of total-reflection x-ray spectrometry in sea-water analysis

    International Nuclear Information System (INIS)

    Since 1986, the ''Bundesamt fur Seeschiffahrt und Hydrographie'' (BSH), has participated in two interdisciplinary North Sea research projects involving trace heavy metal analysis in sea-water. The analysis of heavy metals (such as manganese, iron, nickel, copper, zinc and lead) in sea-water samples has been performed previously by application of total-reflection X-ray fluorescence spectrometry (TXRF). Samples obtained on the first cruise of the following project ''Processes in the Pollutant Transfer between Sea and Atmosphere'' (PRISMA) in September and October 1990, covering parts of the northern North Sea and Atlantic Ocean, were also analysed by TXRF. Results from these two surveys and from the first PRISMA drift experiments in the German Bight in April 1991 show the concentration ranges and variabilities of some heavy metals and are presented here. The ability of TXRF, in connection with tested procedures for sampling, matrix separation and enrichment, to master large quantities of trace heavy metal analyses in sea-water with sufficient analytical quality is demonstrated. (author)

  12. Quantification of potentially toxic elements in sewage and sludge from treatment plants in the cities of Campinas and Jaguariuna using synchrotron radiation total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    The rapid urban and industrial development in last decades has brought as one of the consequences, changes in the environment. The lack of planning of city growth is, today, one of the major causes of water pollution including residential, industrial, agricultural, and hospital waste. The metals contamination is a major problem, causing serious changes to the environment, causing harm to human health. The sludge generated at sewage treatment plants, is an important source of nutrients and organic matter, and therefore it can also be reused mainly for agricultural use, since contaminants are removed. The cities of Campinas and Jaguariuna are inserted in the Campinas Metropolitan Region (CMR), one of the most dynamic regions in the Brazilian economy. Therefore, to study the anthropogenic influences of the cities, evaluated the quality of raw and treated effluent and the sludge generated in sewage treatment plants, especially with regard to heavy metals. Measurements of metals were performed by Synchrotron Radiation Total Reflection X-ray Fluorescence. For treated effluent data were compared to CONAMA 357 law and Cr, Mn, Fe, Ni, Cu, Zn, Ba and Pb showed concentrations in according with the law. To reuse in agriculture the contents were compared to the limits defined by CETESB and some elements had concentrations above to the permitted preventing its reuse. For sludge, Cr, Ni, Cu, Zn, Ba and Pb, in the two treatment plants studied, the concentrations were lower than the maximum permissible values established by CONAMA 375 law allowing the sludge application sludge on agricultural land. (author)

  13. Study on trace elements behaviour in cancerous and healthy tissues of colon, breast and stomach: Total reflection X-ray fluorescence applications

    Energy Technology Data Exchange (ETDEWEB)

    Magalhaes, T. [Centro de Fisica Atomica da Univeridade de Lisboa, Departamento de Fisica da Faculdade de Ciencias, Av. Prof. Gama Pinto, 2, 1649-00, Lisboa (Portugal); Carvalho, M.L., E-mail: luisa@cii.fc.ul.p [Centro de Fisica Atomica da Univeridade de Lisboa, Departamento de Fisica da Faculdade de Ciencias, Av. Prof. Gama Pinto, 2, 1649-00, Lisboa (Portugal); Von Bohlen, A.; Becker, M. [Institute for Analytical Sciences (ISAS), Bunsen-Kirchhoff-Str. 11, 44139 Dortmund (Germany)

    2010-06-15

    In this work Total-reflection X-ray fluorescence (TXRF) was used to analyse healthy and cancerous tissues of the same individual along several contiguous thin sections of each tissue. Thirty two samples (16 pairs) of breast tissue, 30 samples (15 pairs) of intestine tissue and 10 samples (5 pairs) of stomach tissue were analysed. The samples were obtained in Civil Hospitals of Germany (Dortmund) and Portugal (Lisbon). The elemental distribution of P, S, Cl, K, Ca, Cr, Mn, Fe, Ni, Cu, Zn, Se, Br, Rb, Sr and Pb in these samples was studied. Descriptive statistics based on bar graphics and hypotheses tests and also an automatic classification based on hierarchical grouping analysis was used for the several analysed tissues. It was shown that the behaviour of the elements is tissue dependent. Some elements, like P and K exhibit the same behaviour in all the analysed tissue types. They have increased concentrations in all cancerous tissues. Unlike, other elements like Br show completely different behaviour depending on the tissue: similar concentration in healthy and cancerous stomach, decreased levels in colon cancerous tissues and enhanced concentrations in breast was observed. Moreover cancer tissues present decreased Se concentrations on colon and increased on breast.

  14. Analysis of heavy metals and minerals elements in the turmeric using Total-Reflection X-ray Fluorescence analysis technique and Atomic Absorption Spectrometry

    International Nuclear Information System (INIS)

    Currently, many studies demonstrate anti-cancer and anti-inflammatory benefits of turmeric. The aims of this work is to perform analysis of metals such as calcium, chromium, manganese, iron, cobalt, nickel, copper, zinc, arsenic, bromine, rubidium, strontium, cadmium and lead in the turmeric collected from various places in Madagascar. The analysis by total reflection X-ray fluorescence technique is used to determine the concentrations of heavy metals, while the atomic absorption spectrometry is used for the determination of trace elements. Analysis results show that the concentration of calcium in the turmeric is very high, its average concentration is 1025.8 mg.kg-1. The average concentrations of manganese, of copper and of iron are respectively 44.7 mg.kg-1; 19.7 mg.kg-1 and 53.6 mg.kg-1. The average concentrations of zinc, of rubidium and of strontium are respectively 17.3 mg.kg-1; 35.2 mg.kg-1 and 21.7 mg.kg-1

  15. Control algorithms for dynamic attenuators

    Energy Technology Data Exchange (ETDEWEB)

    Hsieh, Scott S., E-mail: sshsieh@stanford.edu [Department of Radiology, Stanford University, Stanford, California 94305 and Department of Electrical Engineering, Stanford University, Stanford, California 94305 (United States); Pelc, Norbert J. [Department of Radiology, Stanford University, Stanford California 94305 and Department of Bioengineering, Stanford University, Stanford, California 94305 (United States)

    2014-06-15

    Purpose: The authors describe algorithms to control dynamic attenuators in CT and compare their performance using simulated scans. Dynamic attenuators are prepatient beam shaping filters that modulate the distribution of x-ray fluence incident on the patient on a view-by-view basis. These attenuators can reduce dose while improving key image quality metrics such as peak or mean variance. In each view, the attenuator presents several degrees of freedom which may be individually adjusted. The total number of degrees of freedom across all views is very large, making many optimization techniques impractical. The authors develop a theory for optimally controlling these attenuators. Special attention is paid to a theoretically perfect attenuator which controls the fluence for each ray individually, but the authors also investigate and compare three other, practical attenuator designs which have been previously proposed: the piecewise-linear attenuator, the translating attenuator, and the double wedge attenuator. Methods: The authors pose and solve the optimization problems of minimizing the mean and peak variance subject to a fixed dose limit. For a perfect attenuator and mean variance minimization, this problem can be solved in simple, closed form. For other attenuator designs, the problem can be decomposed into separate problems for each view to greatly reduce the computational complexity. Peak variance minimization can be approximately solved using iterated, weighted mean variance (WMV) minimization. Also, the authors develop heuristics for the perfect and piecewise-linear attenuators which do not requirea priori knowledge of the patient anatomy. The authors compare these control algorithms on different types of dynamic attenuators using simulated raw data from forward projected DICOM files of a thorax and an abdomen. Results: The translating and double wedge attenuators reduce dose by an average of 30% relative to current techniques (bowtie filter with tube current

  16. Evaluation of growth tree rings of Tipuana Tipu as biomonitoring of environmental pollution by synchrotron radiation total reflection X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Silvana; Geraldo, Simoni Michetti; Canteras, Felippe Benavente, E-mail: silvana@fec.unicamp.br, E-mail: felippe.canteras@gmail.com [Universidade Estadual de Campinas (FEC/UNICAMP), Campinas, SP (Brazil). Dept. de Saneamento e Ambiente

    2013-07-01

    The bioindicators, plants or animals capable to present qualitative and/or quantitative answers, when exposed to pollutant substances. Trees record and incorporate in their log, developed year after year, the impressions of the environment, becoming possible the study of the different environmental changes, including contamination, that have occurred over the life of these trees. The selected species, Tipuana Tipu, of the Leguminosae family, is native of Argentina and Bolivia and was introduced in Brazil as an ornamental plant. It is one of the most common trees in the urban landscaping in Sao Paulo city. The present project has as main objective the determination of the content of potentially toxic elements in samples of growth the tree rings of Tipuana Tipu, previously dated, collected in strategically locations of Sao Paulo, using Synchrotron Radiation Total Reflection X-Ray Fluorescence. Samples were also collected in the Piracicaba (SP), local of little access and small flow traffic. The SR-TXRF analysis was carried out in the X-ray Fluorescence Beamline at the Brazilian Synchrotron Light Source Laboratory, located in Campinas city, Sao Paulo State, Brazil. Some trace elements present concentrations higher than considered as normal in some periods. In this paper the highest value for Pb was 123.54 μg.g{sup -1} considered as threshold value was observed for the period 1998 to 2000 for University of Sao Paulo, Butanta site. For the same period excessive level was also observed for samples collected in Piracicaba city. In Sao Paulo city, sample collected in the campus of University of Sao Paulo (Butanta), showed the highest toxicity, with concentration above the tolerable limit for Ti, Cr and Cu. For the samples collected in Piracicaba city the concentrations of Cr, Ni, Cu, and Pb exceeding the toxicity limits. (author)

  17. Experimental methodology and spectral analysis for the determination of mercury by means of Total Reflection X-Ray Fluorescence, using gold amalgams

    International Nuclear Information System (INIS)

    Full text: In this work is described an experimental and statistical method for the determination of ionic mercury in liquid samples by means of Total Reflection X-Ray Fluorescence. The obtained results by the application of this technique provide reliable results, that have been verified by means of the measurement of benchmarks prepared ad hoc. The usual procedure for the preparation of a sample for TXRF is not applicable for the determination of mercury, because the high vapor pressure of this element causes its evaporation and lost of the target holder. To avoid this effect, the developed method proposes a plaster or previous deposition of a thin layer of gold in the reflector. Later on, it is left in contact with an ionic solution of mercury with the gold, to facilitate the formation of an amalgam. Finally, an analysis is carried out by means of traditional form of TXRF. As the peaks of mercury and gold are overlapped, we developed a formulation that describes the obtained spectrum, in order to derive a data handling that allows to access to precise results; at the same time, it estimates the detection of the method. Two equations are proposed for the analysis, which are applied to the obtained spectra and compare the results. Using a X-ray tube with anode of molybdenum, at 40 kV and 20 mA, the limit of detection obtained for a sample of 10 ml (with 2000 s of counting time) is 250 ppb, lower indeed than the lower limit of ppm units recommended by the EPA

  18. Evaluation of Fe and Zn/Cu ratio in serum of patients with sickle cell anemia by total reflection X-ray fluorescence using synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Canellas, Catarine G.L.; Leitao, Roberta G.; Lopes, Ricardo T., E-mail: catarine@lin.ufrj.b, E-mail: ricardo@lin.ufrj.b [Universidade Federal do Rio de Janeiro (PEN/COPPE/UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-Graduacao de Engenharia. Programa de Engenharia Nuclear. Lab. de Instrumentaco Nuclear; Carvalho, Silvia M.F., E-mail: silvia@hemorio.rj.gov.b [State Institute of Hematology Arthur de Siqueira Cavalcanti (HEMORIO), Rio de Janeiro, RJ (Brazil); Bellido, Alfredo Victor B., E-mail: alfredo@ien.gov.b [Federal Fluminense University (UFF), Niteroi, RJ (Brazil). Chemistry Inst.; Anjos, Marcelino J., E-mail: marcelin@lin.ufrj.b [State University of Rio de Janeiro (UERJ), RJ (Brazil). Physics Inst.

    2011-07-01

    Sickle cell anemia (SCA) is a blood disorder that affects hemoglobin, the protein found in red blood cells that help carry oxygen throughout the body. In this work we have analyzed serum samples from patients with SCA by using total reflection X-ray fluorescence using synchrotron radiation (SRTXRF). The SRTXRF measurements were performed at the X-ray fluorescence beamline at Brazilian National Synchrotron Light Laboratory (LNLS), in Campinas, Sao Paulo using a polychromatic beam. We have studied forty-three patients aged 18-50 years old, suffering from SCA and Sixty healthy volunteers aged 18-60 years old. It was possible to determine the concentrations of the following elements: P, S, Cl, K, Ca, Fe, Cu, Zn, Br and Rb. Student's t-test was applied in order to check whether the two populations (CG x SCA) had the same mean values. It was observed that elemental concentration of P, Cl, K, Fe, Cu, Zn and Br differed significantly ({alpha} = 0.05) between groups of healthy subjects and SCA. The concentrations of K, Fe and Cu in the serum samples of patients with SCA were larger 15%, 120 % and 20 %, respectively, when compared with the CG. On the other hand, the concentrations of P (-20 %), Cl (-6 %), Zn (-25 %) and Br (-22 %) were smaller than the values determined for the control group. The serum level Cu/Zn ratio was significantly higher (60%) in the serum samples of patients with SCA group than the CG. So, the Cu/Zn ratio can be used as an adjuvant index in enhancement for diagnosis of SCA. There are evidences of an association among Fe, Cu, Zn and Cu/Zn in the SCA pathogenesis process. (author)

  19. EXAFS in total reflection (reflEXAFS) for the study of organometallic Pd(II) thiol complexes based self-assembled monolayers on gold

    International Nuclear Information System (INIS)

    Graphical abstract: The molecular structure and organization of organometallic Pd(II) thiolates SAMs and multilayers on Au/Si(1 1 1) were investigated by reflEXAFS. For SAMs, S-Au bond lengths, Pd-S-Au bond angles and molecular orientations were assessed. Research highlights: → Organometallic Pt(II) thiolates deposited as SAMs and multilayers on gold. → Molecular structure and organization of SAMs and multilayers studied by reflEXAFS. → SAMs S-Au bond lengths, Pd-S-Au bond angles and molecular orientations are assessed. - Abstract: The molecular structure and organization of self-assembled monolayers (SAMs) and multilayer films grafted onto Au/Si(1 1 1) surfaces of mononuclear transition metal dialkynyl bridged Pd(II) complexes trans-[HS-Pd(PBu3)2-SH] (1), trans-[HS-Pd(PBu3)2(-C≡C-C6H5)] (2) and of the binuclear complex trans, trans-[HS-Pd(PBu3)2(-C≡C-C6H4-C6H4-C≡C-Pd(PBu3)2-SH] (3), have been investigated by extended X-ray absorption fine structure spectroscopy in total reflection conditions (reflEXAFS). ReflEXAFS analysis of the data lead to determine the local structure around Pd atoms, assessing the square-planar geometry around the transition metal in the multilayers case, preserved in the monolayer regime. The investigation on the SAMs also provided the assessment of the S-Au bond length and Pd-S-Au bond angle and on the molecular orientation on the gold substrate of the complexes, confirmed by quantum chemical calculations.

  20. Elemental changes in hemolymph and urine of Rhodnius prolixus induced by in-vivo exposure to mercury: A study using synchrotron radiation total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    In recent years, the effects of pollution on the health of humans and other vertebrates were extensively studied. However, the effects on some invertebrates are comparatively unknown. Recent studies have demonstrated that toxic metals interfere with the reproduction, development and immune defenses of some terrestrial and marine invertebrates. Some environmental conditions including pollution produce chronic and acute effects on different animal's organs and systems. In this work, we investigated changes in the concentrations of Cl, K, Ca, Fe and Zn in Rhodnius prolixus as insect model. The elements were quantified using urine and hemolymph samples collected on different days after feeding the insects with blood containing HgCl2. The synchrotron radiation total reflection X-ray fluorescence measurements were carried at the X-ray fluorescence beamline facility in Brazilian Synchrotron Light Laboratory. The observation reveals that the calcium level was higher in the hemolymph than in urine. On the other hand, the urine collected from insects treated with HgCl2 showed higher level of Cl than hemolymph samples. Ca, Fe and Zn concentrations decrease drastically in urine samples collected after 2 days of HgCl2 treatment. The regulation of triatomines excretion was discussed pointing out the importance of trace elements. - Highlights: ► Changes in Cl, K, Ca, Fe and Zn contents in Rhodnius prolixus were evaluated. ► In triatomines these elements have not been previously described. ► Cl, Ca, Zn levels were lower than control in hemolymph after 5 days of HgCl2 fed. ► Cl, Ca, Zn levels were higher than control in urine after 2 days of HgCl2 fed.

  1. Elemental changes in hemolymph and urine of Rhodnius prolixus induced by in-vivo exposure to mercury: A study using synchrotron radiation total reflection X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Mantuano, Andrea, E-mail: mantuanoandrea@gmail.com [Physics Institute, State University of Rio de Janeiro (Brazil); Pickler, Arissa; Barroso, Regina C. [Physics Institute, State University of Rio de Janeiro (Brazil); Almeida, Andre P. de; Braz, Delson [Nuclear Engineering Program, Federal University of Rio de Janeiro (Brazil); Cardoso, Simone C. [Physics Institute, Federal University of Rio de Janeiro (Brazil); Gonzalez, Marcelo S. [Department of General Biology, Fluminense Federal University (Brazil); Figueiredo, Marcela B.; Garcia, Eloi S.; Azambuja, Patricia [Laboratory of Biochemistry and Physiology of Insects, Oswaldo Cruz Foundation (Brazil)

    2012-05-15

    In recent years, the effects of pollution on the health of humans and other vertebrates were extensively studied. However, the effects on some invertebrates are comparatively unknown. Recent studies have demonstrated that toxic metals interfere with the reproduction, development and immune defenses of some terrestrial and marine invertebrates. Some environmental conditions including pollution produce chronic and acute effects on different animal's organs and systems. In this work, we investigated changes in the concentrations of Cl, K, Ca, Fe and Zn in Rhodnius prolixus as insect model. The elements were quantified using urine and hemolymph samples collected on different days after feeding the insects with blood containing HgCl{sub 2}. The synchrotron radiation total reflection X-ray fluorescence measurements were carried at the X-ray fluorescence beamline facility in Brazilian Synchrotron Light Laboratory. The observation reveals that the calcium level was higher in the hemolymph than in urine. On the other hand, the urine collected from insects treated with HgCl{sub 2} showed higher level of Cl than hemolymph samples. Ca, Fe and Zn concentrations decrease drastically in urine samples collected after 2 days of HgCl{sub 2} treatment. The regulation of triatomines excretion was discussed pointing out the importance of trace elements. - Highlights: Black-Right-Pointing-Pointer Changes in Cl, K, Ca, Fe and Zn contents in Rhodnius prolixus were evaluated. Black-Right-Pointing-Pointer In triatomines these elements have not been previously described. Black-Right-Pointing-Pointer Cl, Ca, Zn levels were lower than control in hemolymph after 5 days of HgCl{sub 2} fed. Black-Right-Pointing-Pointer Cl, Ca, Zn levels were higher than control in urine after 2 days of HgCl{sub 2} fed.

  2. Fluorescently-Labeled Estradiol Internalization and Membrane Trafficking in Live N-38 Neuronal Cells Visualized with Total Internal Reflection Fluorescence Microscopy.

    Science.gov (United States)

    Kisler, Kassandra; Chow, Robert H; Dominguez, Reymundo

    2013-04-20

    Estradiol is a steroid hormone that binds and activates estradiol receptors. Activation of these receptors is known to modulate neuronal physiology and provide neuroprotection, but it is not completely understood how estradiol mediates these actions on the nervous system. Activation of a sub-population of estradiol receptor-α (ERα), originally identified as a nuclear protein, localizes to the plasma membrane and appears to be a critical step in neuroprotection against brain injury and disease. Previously we showed that estradiol stimulates the rapid and transient trafficking of plasma membrane ERα in primary hypothalamic neurons, and internalization of membrane-impermeant estradiol (E6BSA-FITC) into cortical neuron endosomes in vitro. These findings support the concept that estradiol activates and down-regulates plasma membrane ERα by triggering endocytosis. Here, we use TIRFM (total internal reflection fluorescence microscopy) to image the trafficking of E6BSA-FITC, and GFP-labeled ERα, in live cells in real time. We show that activation of plasma membrane ERs by E6BSA-FITC result in internalization of the fluorescent ligand in live N-38 neurons, an immortalized hypothalamic cell line. Pretreatment with ER antagonist ICI 182,780 decreased the number of E6BSA-FITC labeled puncta observed. We also observed in live N-38 neurons that E6BSA-FITC co-localized with FM4-64 and LysoTracker fluorescent dyes that label endosomes and lysosomes. Our results provide further evidence that plasma membrane ERα activation results in endocytosis of the receptor. PMID:24353903

  3. Evaluation of growth tree rings of Tipuana Tipu as biomonitoring of environmental pollution by synchrotron radiation total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    The bioindicators, plants or animals capable to present qualitative and/or quantitative answers, when exposed to pollutant substances. Trees record and incorporate in their log, developed year after year, the impressions of the environment, becoming possible the study of the different environmental changes, including contamination, that have occurred over the life of these trees. The selected species, Tipuana Tipu, of the Leguminosae family, is native of Argentina and Bolivia and was introduced in Brazil as an ornamental plant. It is one of the most common trees in the urban landscaping in Sao Paulo city. The present project has as main objective the determination of the content of potentially toxic elements in samples of growth the tree rings of Tipuana Tipu, previously dated, collected in strategically locations of Sao Paulo, using Synchrotron Radiation Total Reflection X-Ray Fluorescence. Samples were also collected in the Piracicaba (SP), local of little access and small flow traffic. The SR-TXRF analysis was carried out in the X-ray Fluorescence Beamline at the Brazilian Synchrotron Light Source Laboratory, located in Campinas city, Sao Paulo State, Brazil. Some trace elements present concentrations higher than considered as normal in some periods. In this paper the highest value for Pb was 123.54 μg.g-1 considered as threshold value was observed for the period 1998 to 2000 for University of Sao Paulo, Butanta site. For the same period excessive level was also observed for samples collected in Piracicaba city. In Sao Paulo city, sample collected in the campus of University of Sao Paulo (Butanta), showed the highest toxicity, with concentration above the tolerable limit for Ti, Cr and Cu. For the samples collected in Piracicaba city the concentrations of Cr, Ni, Cu, and Pb exceeding the toxicity limits. (author)

  4. Evaluation of Fe and Zn/Cu ratio in serum of patients with sickle cell anemia by total reflection X-ray fluorescence using synchrotron radiation

    International Nuclear Information System (INIS)

    Sickle cell anemia (SCA) is a blood disorder that affects hemoglobin, the protein found in red blood cells that help carry oxygen throughout the body. In this work we have analyzed serum samples from patients with SCA by using total reflection X-ray fluorescence using synchrotron radiation (SRTXRF). The SRTXRF measurements were performed at the X-ray fluorescence beamline at Brazilian National Synchrotron Light Laboratory (LNLS), in Campinas, Sao Paulo using a polychromatic beam. We have studied forty-three patients aged 18-50 years old, suffering from SCA and Sixty healthy volunteers aged 18-60 years old. It was possible to determine the concentrations of the following elements: P, S, Cl, K, Ca, Fe, Cu, Zn, Br and Rb. Student's t-test was applied in order to check whether the two populations (CG x SCA) had the same mean values. It was observed that elemental concentration of P, Cl, K, Fe, Cu, Zn and Br differed significantly (α = 0.05) between groups of healthy subjects and SCA. The concentrations of K, Fe and Cu in the serum samples of patients with SCA were larger 15%, 120 % and 20 %, respectively, when compared with the CG. On the other hand, the concentrations of P (-20 %), Cl (-6 %), Zn (-25 %) and Br (-22 %) were smaller than the values determined for the control group. The serum level Cu/Zn ratio was significantly higher (60%) in the serum samples of patients with SCA group than the CG. So, the Cu/Zn ratio can be used as an adjuvant index in enhancement for diagnosis of SCA. There are evidences of an association among Fe, Cu, Zn and Cu/Zn in the SCA pathogenesis process. (author)

  5. TOMS/Earth-Probe Total Ozone Aerosol Index UV-Reflectivity UV-B Erythemal Irradiance Daily L3 Global 1x1.25 deg V008

    Data.gov (United States)

    National Aeronautics and Space Administration — The Total Ozone Mapping Spectrometer (TOMS) version 8 daily global gridded data consist of total column ozone, aerosol index, Lambertian effective surface...

  6. Characterizations of the mirror attenuator mosaic - Solar diffuser plate

    Science.gov (United States)

    Lee, Robert B., III; Avis, Lee M.; Gibson, M. A.; Kopia, Leonard P.

    1992-01-01

    The mirror attenuator mosaic (MAM), a solar diffuser plate, was used for the flight calibration of the broadband shortwave (0.2-5-microns) and total (0.2 to greater than 200-microns) Earth Radiation Budget Experiment scanning thermistor bolometer radiometers. The MAM solar-reflecting surface consisted of a tightly packed array of vacuum-deposited aluminum, concave spherical mirrors, while its solar-absorbing surface consisted of black chrome. The effective reflectance of the MAM was constant to within +/- 2 percent after almost 2 years in orbit, a marked improvement over earlier solar diffusers.

  7. Stress Wave Reflecting Attenuation to Improve Anti-shock Capacity by Gasket%垫片提高抗冲击能力的应力波衰减机理

    Institute of Scientific and Technical Information of China (English)

    徐蓬朝; 黄惠东; 张龙山; 周平; 许冉

    2012-01-01

    Most of researches on anti-shock for penetrating fuze suggests that elasto-plastic gasket materials can be used because of their properties of cushion and energy-absorption. But the theory of cushion can hardly explain that why the gasket can improve fuze parts anti-shock capacity. In this paper, stress wave attenuating by gasket was regarded as the major factor of anti-shock. The large percentage of stress wave was reflected at fuze-shell/gasket interface. The gasket had few effects on acceleration but significant on attenuating fluctuation of stress wave. The simulation results indicateed that (1) the less of the impedance, the better of attenuation; (2) the thickness of the gaskets had few effects on attenuations (3)multilayer different gaskets were much better.%引信零部件抗高过载冲击,目前大多文献和资料提到用弹塑性垫片材料进行缓冲、吸能,但是缓冲理论并不能解释垫片提高引信零部件耐高过载能力.为此,提出垫片提高引信零部件抗冲击能力的机理主要是应力波反射衰减,即机械滤波.根据应力波在不同界面的反射与透射理论,冲击应力波在通过结构件与垫片的分界面时,因大部分被反射而衰减,垫片提高被保护件抗冲击能力的主要原因不是弹性缓冲,而是机械滤波;垫片对于被保护件质心惯性加速度影响很小,却能显著衰减骑在质心加速度曲线上的应力波,降低二者的合力尖峰,并减少往复振动冲击的破坏.仿真表明:垫片滤波说比缓冲说更合理,并且,波阻抗越小的垫片,机械滤波效果越好;只要远小于有效缓冲厚度,垫片厚度对机械滤波贡献不大;使用不同材料的两层垫片优于同厚度的单一材质垫片,多层更好.

  8. Analyses of heavy metals in sewage and sludge from treatment plants in the cities of Campinas and Jaguariúna, using synchrotron radiation total reflection X-rayfluorescence

    International Nuclear Information System (INIS)

    A major consequence of accelerated urban and industrial development in the last decades is water pollution. In particular, metal contamination is a significant problem, causing serious changes to the environment and adversely affecting human health. The cities of Campinas and Jaguariúna are inserted in the Campinas Metropolitan Region (CMR), one of the most dynamic regions in the Brazilian economy, accounting for 2.7% of Gross National Product (GNP) and 7.83% of São Paulo State Product—or approximately $ 70.7 billion per year. Besides having a strong economy, the region also presents an infrastructure that provides the development of the entire metropolitan area. Therefore, to study the anthropogenic influences of the cities, the evaluation of the quality of raw and treated effluent and, the sludge generated in sewage treatment plants (STP), especially with regard to heavy metals was performed by Total Reflection X-Ray Fluorescence with Synchrotron Radiation technique. The results were compared with the allowed values established by Brazilian Legislation. For raw and treated effluents collected in Jaguariúna and Campinas city in the Stations of Treatment of Sewage (Camanducaia and Anhumas), Cr presented higher concentrations than the maximum allowed values established by CONAMA 357. However, it is necessary to do other studies to define the fraction of Cr+3 and Cr+6 to compare to the new legislation. The other elements were in agreement with established regulations. For sludge sampled in the same locations, the concentrations of Cr, Cu, Pb, Ni and Zn were compared with the CONAMA 375 and showed values smaller than the maximum allowed values, indicating the possibility to re-use the sludge. - Highlights: ► Analysis of sewage and sludge composition using SR-TXRF. ► Determination of the potentially toxic elements like Cr, Ni, Cu, Zn and Pb. ► Concentrations determined were compared with Brazilian quality standards. ► It was discovered possible illegal

  9. Determination of metals in samples of Cocuy hand craft penca, produced in Lara State, Venezuela, by use of Total Reflection X-Ray Fluorescence

    International Nuclear Information System (INIS)

    Full text: The cocuy is a hydro alcoholic mixture coming from the distillation of fermented juice of agave cocuy. It is originate from Venezuela and it is produced in arid and semi-arid regions of that Country. In the last years, government has been concerned to obtain the legalization of the cocuy produced by peasants from the Municipality Urdaneta. The characterization of the cocuy produced in this municipality is an important contribution for the community and for the health of the consumers. To study the characteristics of the process of cocuy production in that region, it was carried out a census of producers, and a survey was applied in order to obtain information about raw material, process and storage of the cocuy. Samples were taken from different producers, to which it was determined p H, acidity, alcoholic degree, dry extract, refraction index, and content of Cu, Zn, Fe and Pb. The determination of metal in samples of cocuy was carried out by the method of Total Reflection X-Ray Fluorescence. This technique is very appropriate for alcoholic matrices, since effects of matrices are not observed, contrary to the technique of Atomic Absorption, which is the suitable one for the quality standards for this kind of drinks. The method TXRF has the additional advantage of the simultaneous determination with sample volumes of microliters order. The in situ internal standardization (in the reflector) was investigated by use of two methodologies, and the traditional procedure of addition of the internal pattern was compared. The analytic quality of the obtained results for each procedure it was object of analysis and it will be discussed. The concentration of metal Zn, Fe and Pb was near to limit of detection of the technique. The accuracy of the obtained results for Cu was determined by comparison with the technique of Atomic Absorption and it will also be object of discussion. They were found differences between the content of metal and the alcoholic degree, among

  10. Single molecule investigations of DNA looping using the tethered particle method and translocation by acto-myosin using polarized total internal reflection fluorescence microscopy

    Science.gov (United States)

    Beausang, John F.

    Single molecule biophysics aims to understand biological processes by studying them at the single molecule level in real time. The proteins and nucleic acids under investigation typically exist in an aqueous environment within ˜ ten degrees of room temperature. These seemingly benign conditions are actually quite chaotic at the nanoscale, where single bio-molecules perform their function. As a result, sensitive experiments and statistical analyses are required to separate the weak single molecule signal from its background. Protein-DNA interactions were investigated by monitoring DNA looping events in tethered particle experiments. A new analysis technique, called the Diffusive hidden Markov method, was developed to extract kinetic rate constants from experimental data without any filtering of the raw data; a common step that improves the signal to noise ratio, but at the expense of lower time resolution. In the second system, translocation of the molecular motor myosin along its actin filament track was studied using polarized total internal reflection (polTIRF) microscopy, a technique that determines the orientation and wobble of a single fluorophore attached to the bio-molecule of interest. The range of resolvable angles was increased 4-fold to include a hemisphere of possible orientations. As a result, the handedness of actin filament twirling as it translocated along a myosin-coated surface was determined to be left-handed. The maximum time resolution of a polTIRF setup was increased 50-fold, in part by recording the arrival times and polarization state of single photons using a modified time-correlated single photon counting device. A new analysis, the Multiple Intensity Change Point algorithm, was developed to detect changes in molecular orientation and wobble using the raw time-stamped data with no user-defined bins or thresholds. The analysis objectively identified changes in the orientation of a bifunctional-rhodamine labeled calmodulin that was attached

  11. Ultrasound transmission attenuation tomography using energy-scaled amplitude ratios

    Science.gov (United States)

    Chen, Ting; Shin, Junseob; Huang, Lianjie

    2016-04-01

    Ultrasound attenuation of breast tumors is related to their types and pathological states, and can be used to detect and characterize breast cancer. Particularly, ultrasound scattering attenuation can infer the margin properties of breast tumors. Ultrasound attenuation tomography quantitatively reconstructs the attenuation properties of the breast. Our synthetic-aperture breast ultrasound tomography system with two parallel transducer arrays records both ultrasound reflection and transmission signals. We develop an ultrasound attenuation tomography method using ultrasound energy-scaled amplitude decays of ultrasound transmission signals and conduct ultrasound attenuation tomography using a known sound-speed model. We apply our ultrasound transmission attenuation tomography method to a breast phantom dataset, and compare the ultrasound attenuation tomography results with conventional beamforming ultrasound images obtained using reflection signals. We show that ultrasound transmission attenuation tomography complements beamforming images in identifying breast lesions.

  12. Reflecting Reflective Practice

    Science.gov (United States)

    Galea, Simone

    2012-01-01

    This paper demystifies reflective practice on teaching by focusing on the idea of reflection itself and how it has been conceived by two philosophers, Plato and Irigaray. It argues that reflective practice has become a standardized method of defining the teacher in teacher education and teacher accreditation systems. It explores how practices of…

  13. Reflecting reflection in supervision

    DEFF Research Database (Denmark)

    Lystbæk, Christian Tang

    Reflection has moved from the margins to the mainstream in supervision. Notions of reflection have become well established since the late 1980s. These notions have provided useful framing devices to help conceptualize some important processes in guidance and counseling. However, some applications...... previously associated with reflection and an exploration of alternative conceptions that view reflection within the context of settings which have a more group- and team-based orientation. Drawing on an action research project on health care supervision, the paper questions whether we should reject earlier...... views of reflection, rehabilitate them in order to capture broader connotations or move to new ways of regarding reflection that are more in keeping with not only reflective but also emotive, normative and formative views on supervision. The paper presents a critical perspective on supervision that...

  14. Total and free insulin-like growth factor I, insulin-like growth factor binding protein 3 and acid-labile subunit reflect clinical activity in acromegaly

    DEFF Research Database (Denmark)

    Sneppen, S B; Lange, Merete Wolder; Pedersen, L M;

    2001-01-01

    insulin-like growth factor binding protein-3 (IGFBP-3) with PV(pos) of 0.69 and 0.71 and PV(neg) of 0.91 and 0.92 respectively. We conclude that free IGF-I is more closely related than total IGF-I to perceived disease activity and is as such useful when evaluating previously treated acromegaly for disease...... activity. Total IGF-I, IGFBP-3 and ALS possess a higher PV(neg) for the clinical disease activity. None of the parameters can at present be claimed to be superior to the others and thus all the measured parameters are recommended to be part of the evaluation of acromegalic patients....

  15. Total and free insulin-like growth factor I, insulin-like growth factor binding protein 3 and acid-labile subunit reflect clinical activity in acromegaly

    DEFF Research Database (Denmark)

    Sneppen, S B; Lange, Merete Wolder; Pedersen, L M; Kristensen L, L Ø; Main, K M; Juul, A; Skakkebaek, N E; Feldt-Rasmussen, U

    2001-01-01

    insulin-like growth factor binding protein-3 (IGFBP-3) with PV(pos) of 0.69 and 0.71 and PV(neg) of 0.91 and 0.92 respectively. We conclude that free IGF-I is more closely related than total IGF-I to perceived disease activity and is as such useful when evaluating previously treated acromegaly for disease...... the inactive and the active groups, we found that positive and negative predictive values (PV(pos), PV(neg)) for clinical disease activity of total and free insulin-like growth factor-I (IGF-I) were 0.59, 0.90 and 1.00, 0.82 respectively. Acid-labile subunit (ALS) showed diagnostic merit similar to...... activity. Total IGF-I, IGFBP-3 and ALS possess a higher PV(neg) for the clinical disease activity. None of the parameters can at present be claimed to be superior to the others and thus all the measured parameters are recommended to be part of the evaluation of acromegalic patients....

  16. Reflecting on Cherenkov reflections

    OpenAIRE

    Fargion, D.; Gaug, M.; Oliva, P.

    2007-01-01

    Magic Telescope may observe and reveal at horizons lights from air-shower Cherenkov reflections. The ground, the sea, the cloudy sky (below the mountain) may reflect PeVs-EeV UHECR Cherenkov lights observable by MAGIC telescopes. Even rarest UHE neutrino skimming the atmosphere or skimming the Earth may induce upward-horizontal airshowers: a new Neutrino Astronomy. These fluorescence signals or the Cherenkov reflections in upper cloudy sky may flash in correlated BL-Lac or GRB shining at oppo...

  17. Rotary antenna attenuator

    Science.gov (United States)

    Dickinson, R. M.; Hardy, J. C.

    1969-01-01

    Radio frequency attenuator, having negligible insertion loss at minimum attenuation, can be used for making precise antenna gain measurements. It is small in size compared to a rotary-vane attenuator.

  18. Mapping of Total Carbon and Clay Contents in Glacial Till Soil Using On-the-Go Near-Infrared Reflectance Spectroscopy and Partial Least Squares Regression

    Institute of Scientific and Technical Information of China (English)

    SHEN Zhang-Quan; SHAN Ying-Jie; PENG Li; JIANG Yu-Gen

    2013-01-01

    Characterizing spatial variability of soil attributes,using traditional soil sampling and laboratory analysis,is cost prohibitive.The potential benefit of managing soils on a site-specific basis is well established.High variations in glacial till soil render detailed soil mapping difficult with limited number of soil samples.To overcome this problem,this paper demonstrates the feasibility of soil carbon and clay mapping using the newly developed on-the-go near-infrared reflectance spectroscopy (NIRS).Compared with the geostatistics method,the partial least squares regression (PLSR),with NIRS measurements,could yield a more detailed map for both soil carbon and clay.Further,by using independent validation dataset,the accuracy of predicting could be improved significantly for soil clay content and only slightly for soil carbon content.Owing to the complexity of field conditions,more work on data processing and calibration modeling might be necessary for using on-the-go NIRS measurements.

  19. Carbon monoxide total columns from SCIAMACHY 2.3 μm atmospheric reflectance measurements: towards a full-mission data product (2003-2012)

    Science.gov (United States)

    Borsdorff, T.; Tol, P.; Williams, J. E.; de Laat, J.; aan de Brugh, J.; Nédélec, P.; Aben, I.; Landgraf, J.

    2015-09-01

    We present a full-mission data product of carbon monoxide (CO) vertical column densities using the 2310-2338 nm SCIAMACHY reflectance measurements over clear sky land scenes for the period January 2003-April 2012. The retrieval employs the SICOR algorithm, which will be used for operational data processing of the Sentinel-5 Precursor mission, combined with a SCIAMACHY specific radiometric soft-calibration to mitigate instrumental issues. The retrieval approach infers simultaneously carbon monoxide, methane and water vapour column densities together with a Lambertian surface albedo from individual SCIAMACHY measurements employing a non-scattering radiative transfer model. To account for the radiometric instrument degradation including the formation of an ice-layer on the 2.3 μm detector-array, we consider clear sky measurements over the Sahara as a natural calibration target. For these specific measurements, we spectrally calibrate the SCIAMACHY measurements and determine a spectral radiometric offset and the width of the instrument spectral response function as a function of time for the entire operational phase of the mission. We show that the smoothing error of individual clear sky CO retrievals is less than ±1 ppb and thus this error contribution has not to be accounted for in the validation considering the much higher retrieval noise. The CO data product is validated against measurements of ground-based Fourier transform infrared spectrometers at 27 stations of the NDACC-IRWG and TCCON network and MOZAIC/IAGOS aircraft measurements at 26 airports worldwide. Overall, we find a good agreement with TCCON measurements with a mean bias b = -1.2 ppb and a station-to-station bias with σ = 7.2 ppb. For the NDACC-IRWG network, we obtain a larger mean station bias of b = -9.2 ppb with σ = 8.1 ppb and for the MOZAIC/IAGOS measurements we find b = -6.4 ppb with σ = 5.6 ppb. The SCIAMACHY data set is subject to a small but significant trend of 1.47 ± 0.25 ppb yr-1

  20. Carbon monoxide total columns from SCIAMACHY 2.3 µm atmospheric reflectance measurements: towards a full-mission data product (2003-2012)

    Science.gov (United States)

    Borsdorff, T.; Tol, P.; Williams, J. E.; de Laat, J.; aan de Brugh, J.; Nédélec, P.; Aben, I.; Landgraf, J.

    2016-01-01

    We present a full-mission data product of carbon monoxide (CO) vertical column densities using the 2310-2338 nm SCIAMACHY reflectance measurements over clear-sky land scenes for the period January 2003-April 2012. The retrieval employs the SICOR algorithm, which will be used for operational data processing of the Sentinel-5 Precursor mission. The retrieval approach infers simultaneously carbon monoxide, methane and water vapour column densities together with a Lambertian surface albedo from individual SCIAMACHY measurements employing a non-scattering radiative transfer model. To account for the radiometric instrument degradation including the formation of an ice-layer on the 2.3 µm detector array, we consider clear-sky measurements over the Sahara as a natural calibration target. For these specific measurements, we spectrally calibrate the SCIAMACHY measurements and determine a spectral radiometric offset and the width of the instrument spectral response function as a function of time for the entire operational phase of the mission. We show that the smoothing error of individual clear-sky CO retrievals is less than ±1 ppb and thus this error contribution does not need to be accounted for in the validation considering the much higher retrieval noise. The CO data product is validated against measurements of ground-based Fourier transform infrared spectrometers at 27 stations of the NDACC-IRWG and TCCON network and MOZAIC/IAGOS aircraft measurements at 26 airports worldwide. Overall, we find a good agreement with TCCON measurements with a mean bias b = -1.2 ppb and a station-to-station bias with σ = 7.2 ppb. The negative sign of the bias means a low bias of SCIAMACHY CO with respect to TCCON. For the NDACC-IRWG network, we obtain a larger mean station bias of b = -9.2 ppb with σ = 8.1 ppb and for the MOZAIC/IAGOS measurements we find b = -6.4 ppb with σ = 5.6 ppb. The SCIAMACHY data set is subject to a small but significant bias trend of 1.47 ± 0.25 ppb yr-1

  1. DC attenuation meter

    Science.gov (United States)

    Hargrove, Douglas L.

    2004-09-14

    A portable, hand-held meter used to measure direct current (DC) attenuation in low impedance electrical signal cables and signal attenuators. A DC voltage is applied to the signal input of the cable and feedback to the control circuit through the signal cable and attenuators. The control circuit adjusts the applied voltage to the cable until the feedback voltage equals the reference voltage. The "units" of applied voltage required at the cable input is the system attenuation value of the cable and attenuators, which makes this meter unique. The meter may be used to calibrate data signal cables, attenuators, and cable-attenuator assemblies.

  2. Characterization of the impurity profile at the SiO2/Si interface using a combination of total reflection X-ray fluorescence spectrometry and successive etching of silicon

    International Nuclear Information System (INIS)

    During the fabrication process of integrated circuits, dopant atoms segregate to energetically favorable sites at the interface between silicon and silicon dioxide. Because of the continuously shrinking device dimensions, this effect becomes even more significant. To describe it quantitatively within the framework of Technology Computer-Aided Design, the concentration profile at and near the SiO2/Si interface has to be characterized accurately. Total Reflection X-ray Fluorescence Spectrometry (TXRF) with successive etching was used to determine the impurity profile at the SiO2/Si interface with a resolution on the order of a nanometer

  3. Formation of binary and ternary metal deposits on glass-ceramic carbon electrode surfaces: electron-probe X-ray microanalysis, total-reflection X-ray fluorescence analysis, X-ray photoelectron spectroscopy and scanning electron microscopy study

    International Nuclear Information System (INIS)

    The features of the formation of binary and ternary alloys during the electrochemical deposition and co-deposition of copper, cadmium and lead from aqueous solutions on disc glass-ceramic carbon electrode surfaces were studied by electron-probe X-ray microanalysis, total-reflection X-ray fluorescence analysis, X-ray photoelectron spectroscopy and scanning electron microscopy. The macroscopic properties of electrodeposits such as morphology, lateral distribution of the elements along the disc electrode surface and depth distribution of the elements in the electrodeposit bulk were established. The mechanisms of metal nucleation and growth of thin films of electrodeposits were discussed

  4. Trace metal determination by total-reflection x-ray fluorescence (TXRF) for the differentiation between pure fuel oil (bunker oil) and waste oil (sludge) in maritime shipping legal cases

    International Nuclear Information System (INIS)

    Using a simple sample preparation technique, the concentrations of Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn and Pb in several bunker and sludge oils have been measured simultaneously by total-reflection X-ray fluorescence analysis (TXRF) in the mg/kg range. As a result, five elements are suitable in distinguishing between both types of oil: Ca, V, Fe, Ni and Zn. This differentiation can be used in cases where shipping vessel captains or chiefs attempt to conceal illegal waste oil discharge at sea by wrongly declaring bunker oil as sludge. (author)

  5. Trace metal determination by total-reflection X-ray fluorescence (TXRF) for the differentiation between pure fuel oil (bunker oil) and waste oil (sludge) in maritime shipping legal cases

    Science.gov (United States)

    Schirmacher, Martina; Freimann, Peter; Schmidt, Diether; Dahlmann, Gerhard

    1993-02-01

    Using a simple sample preparation technique, the concentrations of Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn and Pb in several bunker and sludge oils have been measured simultaneously by total-reflection X-ray fluorescence analysis (TXRF) in the mg/kg range. As a result, five elements are suitable in distinguishing between both types of oil: Ca, V, Fe, Ni and Zn. This differentiation can be used in cases where shipping vessel captains or chiefs attempt to conceal illegal waste oil discharge at sea by wrongly declaring bunker oil as sludge.

  6. Investigation of photon attenuation coefficients for marble

    International Nuclear Information System (INIS)

    The total linear attenuation coefficients μ (cm-1) have been obtained using the XCOM program at photon energies of 1 keV to 1 GeV for six different natural marbles produced in different places in Turkey. The individual contribution of photon interaction processes to the total linear attenuation coefficients for marble has been investigated. The calculated results were also compared with the measurements. The results obtained for marble were also compared with concrete. (note)

  7. Reflective Teaching

    Science.gov (United States)

    Farrell, Thomas S. C.

    2013-01-01

    Thomas Farrell's "Reflective Teaching" outlines four principles that take teachers from just doing reflection to making it a way of being. Using the four principles, Reflective Practice Is Evidence Based, Reflective Practice Involves Dialogue, Reflective Practice Links Beliefs and Practices, and Reflective Practice Is a Way of Life,…

  8. Pressure surge attenuator

    Science.gov (United States)

    Christie, Alan M.; Snyder, Kurt I.

    1985-01-01

    A pressure surge attenuation system for pipes having a fluted region opposite crushable metal foam. As adapted for nuclear reactor vessels and heads, crushable metal foam is disposed to attenuate pressure surges.

  9. Photonic Crystal Fiber Attenuator

    Institute of Scientific and Technical Information of China (English)

    Joo Beom Eom; Hokyung Kim; Jinchae Kim; Un-Chul Paek; Byeong Ha Lee

    2003-01-01

    We propose a novel fiber attenuator based on photonic crystal fibers. The difference in the modal field diameters of a conventional single mode fiber and a photonic crystal fiber was used. A variable optical attenuator was also achieved by applying macro-bending on the PCF part of the proposed attenuator

  10. Reflection, Reflective Practice and Embodied Reflective Practice

    OpenAIRE

    Leigh, Jennifer S; Bailey, Richard

    2013-01-01

    Although widely employed in professional practice of all kinds, ‘reflection’ and ‘reflective practice’ can be considered ‘success words’. That is, they elicit positive and supportive responses and yet the concepts are vague, ill-defined, contradictory and reflective skills can be hard to teach. Using examples from education and somatic movement therapy, we argue that a purely analytical approach to reflective practice that involves reflecting on thoughts alone is likely to lead into a negativ...

  11. Reflection Coefficients.

    Science.gov (United States)

    Greenslade, Thomas B., Jr.

    1994-01-01

    Discusses and provides an example of reflectivity approximation to determine whether reflection will occur. Provides a method to show thin-film interference on a projection screen. Also applies the reflectivity concepts to electromagnetic wave systems. (MVL)

  12. Attenuation layer for magnetostatic wave (MSW) absorbers

    Science.gov (United States)

    Glass, H. L.; Adkins, L. R.; Stearns, F. S.

    1984-09-01

    A new technique has been developed for the suppression of MSW end reflections which give rise to passband ripple. The basic idea is to provide a thin film of highly attenuating epitaxial material at the ends of a MSW delay line while preserving high quality YIG in the active region of the device. The GGG wafer preparation is a three step process which involves: (1) the growth of the attenuation layer, (2) the removal of this layer from the central region of the wafer and (3) the growth of high quality YIG on the remaining structure. Delay lines using the attenuation layer for end terminations have been evaluated experimentally and compared to devices utilizing other termination methods. The results indicate that the attenuation layer method produces ripple suppression characteristics which are the equal of those obtained with other termination techniques. The advantage of this new method lies in its suitability for large quantity fabrication requirements.

  13. Aspects of flow attenuation performance of retention ponds

    Science.gov (United States)

    Wallis, S. G.; Morgan, C. T.; Heal, K.

    2003-04-01

    was used in all simulations, based on the results of a time step analysis, undertaken to ensure that accurate solutions were being obtained. As expected, the total outflow volume was found to be related only to the total inflow volume and the static storage available at the start of the inflow hydrograph. The peak outflow was found to reduce with increasing static storage and to reduce with decreasing weir angle. All three time delays were found to increase with increasing static storage, which simply reflects the increasing time required for the inflow to occupy the storage available. Decreasing the weir angle increased the peak and centroid time delays but had no effect on the initial time delay. This reflects the control exercised by the weir once outflow begins, and illustrates the role of the dynamic storage (i.e. the temporary storage available above the weir crest elevation). In summary, the flow attenuation performance of the pond was improved (reduced peak outflow and increased time delays) by reducing the weir angle but was worsened by reducing the static storage. Although the nature of these results are entirely predictable, they highlight two key aspects of the long term performance of retention ponds. Firstly, accumulation of sediment will eventually reduce a pond’s ability to attenuate flows and secondly short dry periods between storms adversely affects their attenuation performance. Neither of these features are routinely taken into account during the design of SUDS in Scotland, yet the effect on the receiving water course could be significant. For example, the earlier occurrence of a larger peak outflow (compared to the design condition) could lead to local flooding if it were to coincide with the time of the peak flow in the watercourse. Currently SUDS are designed for individual sites, but, as they become more prevalent, catchment management will need to examine the design and performance of SUDS within the context of the whole catchment.

  14. Quantitative analysis of X-band weather radar attenuation correction accuracy

    Directory of Open Access Journals (Sweden)

    A. Berne

    2006-01-01

    Full Text Available At short wavelengths, especially C-, X-, and K-band, weather radar signals are attenuated by the precipitation along their paths. This constitutes a major source of error for radar rainfall estimation, in particular for intense precipitation. A recently developed stochastic simulator of range profiles of raindrop size distributions (DSD provides a controlled experiment framework to investigate the accuracy and robustness of attenuation correction algorithms. The work presented here focuses on the quantification of the influence of uncertainties concerning radar calibration, the parameterization of power law relations between the integral variables (radar reflectivity Z and specific attenuation k, and total path integrated attenuation (PIA estimates at X-band. The analysis concerns single frequency, incoherent and non-polarimetric radar systems. Two attenuation correction algorithms, based on a forward and a backward implementation respectively, are studied. From DSD range profiles, the corresponding profiles of integral radar variables are derived. Using a Monte Carlo approach, the accuracy and robustness of the two algorithms are quantified for the different sources of error previously mentioned. This framework of realistic DSD variability provides a robust way to confirm that, under realistic assumptions concerning the PIA estimation uncertainty, the forward algorithm outperforms the backward algorithm for PIA values below 10 dB.

  15. The photon attenuation coefficients of barite, marble and limra

    International Nuclear Information System (INIS)

    The linear attenuation coefficients μ (cm-1) and total mass attenuation coefficients ((μ)/(ρ)) (cm2 g-1) of γ-rays for barite, marble and limra have been calculated using the XCOM program (Version 3.1) at energies from 1 keV to 300 MeV. The calculated results were compared with the estimation coefficients ((μ)/(ρ)) based on the measured total linear attenuation coefficients (μ)

  16. Microwave attenuation with composite of copper microwires

    Energy Technology Data Exchange (ETDEWEB)

    Gorriti, A.G.; Marin, P. [Instituto de Magnetismo Aplicado, (UCM-ADIF-CSIC) and Departamento de Fisica de Materiales (UCM). P.O. Box 155, Las Rozas, Madrid 28230 (Spain); Cortina, D. [Micromag S.L., Las Rozas, Madrid 28230 (Spain); Hernando, A., E-mail: antonio.hernando@adif.e [Instituto de Magnetismo Aplicado, (UCM-ADIF-CSIC) and Departamento de Fisica de Materiales (UCM). P.O. Box 155, Las Rozas, Madrid 28230 (Spain); Micromag S.L., Las Rozas, Madrid 28230 (Spain)

    2010-05-15

    It is shown that copper microwires composite media attenuates microwave reflection of metallic surfaces. We show how the distance to the metallic surface, as well as the length and volume fraction of microwires, determine the frequency of maximum absorption and the return loss level. Furthermore, we were able to fit the experimental results with a theoretical model based on Maxwell-Garnett mixing formula.

  17. A new technique for the deposition of standard solutions in total reflection X-ray fluorescence spectrometry (TXRF) using pico-droplets generated by inkjet printers and its applicability for aerosol analysis with SR-TXRF

    International Nuclear Information System (INIS)

    A new technique for the deposition of standard solutions on particulate aerosol samples using pico-droplets for elemental determinations with total reflection X-ray fluorescence spectrometry (TXRF) is described. It enables short analysis times without influencing the sample structure and avoids time consuming scanning of the sample with the exciting beam in SR-TXRF analysis. Droplets of picoliter volume (∼ 5-130 pL) were generated with commercially available and slightly modified inkjet printers operated with popular image processing software. The size of the dried droplets on surfaces of different polarity namely silicone coated and untreated quartz reflectors, was determined for five different printer types and ten different cartridge types. The results show that droplets generated by inkjet printers are between 50 and 200 μm in diameter (corresponding to volumes of 5 to 130 pL) depending on the cartridge type, which is smaller than the width of the synchrotron beam used in the experiments (< 1 mm at an energy of 17 keV at the beamline L at HASYLAB, Hamburg). The precision of the printing of a certain amount of a single element standard solution was found to be comparable to aliquoting with micropipettes in TXRF, where for 2.5 ng of cobalt relative standard deviations of 12% are found. However, it could be shown that the printing of simple patterns is possible, which is important when structured samples have to be analysed

  18. Assessment of the contamination problems resulting from the use of stainless steel needles in liver biopsies by total reflection X-ray fluorescence and inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Percutaneous human liver biopsies taken from living patients could not be repeated; therefore considerable contamination was indirectly disproved. In the present study, the possible contamination of biopsy samples during sample collection was determined using a porcine liver model. Portions of porcine liver were cut by a quartz blade and treated the same as the steel needle biopsy samples. Concentrations determined in samples taken by a quartz device represented the non-contaminated values and were used to determine reproducibility of measurement and intra-individual variations. Additionally, multiple samples taken from a human liver of a patient suffering steatosis during autopsy were used to determine intra-individual variation of element concentrations. Concentration data of non-contaminated samples were compared to data of steel needle biopsy samples. To investigate the possible release of elements from the steel needles the samples were allowed to contact with the needle for different time in a refrigerator at 4 deg. C. Total reflection X-ray fluorescence spectrometry (TXRF) and inductively coupled plasma-mass spectrometry (ICP-MS) were applied for simultaneous determination of Cr, Mn, Fe, Co, Ni, Cu, Zn, Rb, Mo and Pb because of the very low sample demand of the two selected techniques. Although the steel needles in the present study could not be substituted by polypropylene or Teflon utensils, it was demonstrated that the application of needle biopsy sampling in the reported analysis does not involve measurable contamination if contact time is kept to several minutes as usual in the clinical practice

  19. Evaluation of water and sediment of the Graminha and Águas da Serra streams in the city of Limeira (Sp-Brazil) by Synchrotron Radiation Total Reflection X-ray Fluorescence

    Science.gov (United States)

    Moreira, Silvana; Fazza, Elizete Vieira

    2008-12-01

    The city of Limeira is located in the state of São Paulo, Brazil and has the second largest economy and demographic growth of the state. It comprises an expressive economy with industries in several productive sectors. The source of the Graminha and Águas da Serra streams is located within the Limeira urban zone. The streams cross part of the rural zone and unite by draining into the Piracicaba River. It is possible that these basins suffer or have already suffered the impacts of environmental pollution caused by anthropogenic factors. Since the city has galvanization industries for the production of precious and semi-precious jewels as well as imitation jewelry, the concentration descriptions and interpretations of heavy metals in waters and sediments indicate anthropogenic influence and the dumping of these compounds into the Piracicaba River. The Synchrotron Radiation Total Reflection X-Ray Fluorescence (SR-TXRF) was used for determining the metals. All measurements were performed using a white beam of synchrotron radiation for excitation and a Ge hyperpure detector. Detection limits for water samples were 0.04 μg L - 1 and in sediment samples 0.03 μg g - 1 for Cu and Zn elements. In the water samples, concentrations higher than permissible as established by the Brazilian legislation (CONAMA) for Al, Fe, Zn, Cr, Ni, Cu and Pb, were observed. For sediment samples, values higher than quality reference values defined by the Brazilian legislation (CETESB) were verified for Cr, Zn, Cu, Ni and Pb.

  20. Quantitative determination on heavy metals in different stages of wine production by Total Reflection X-ray Fluorescence and Energy Dispersive X-ray Fluorescence: Comparison on two vineyards

    Energy Technology Data Exchange (ETDEWEB)

    Pessanha, Sofia [Centro Fisica Atomica, Departamento de Fisica, Faculdade de Ciencias, Universidade de Lisboa, Av. Prof. Gama Pinto, 2, 1649-003 Lisboa (Portugal); Carvalho, Maria Luisa, E-mail: luisa@cii.fc.ul.p [Centro Fisica Atomica, Departamento de Fisica, Faculdade de Ciencias, Universidade de Lisboa, Av. Prof. Gama Pinto, 2, 1649-003 Lisboa (Portugal); Becker, Maria; Bohlen, Alex von [Institute for analytical Sciences, Bunsen-Kirchhoff-Str. 11, 44139 Dortmund (Germany)

    2010-06-15

    The purpose of this study is to determine the elemental content, namely heavy metals, of samples of vine-leaves, grapes must and wine. In order to assess the influence of the vineyard age on the elemental content throughout the several stages of wine production, elemental determinations of trace elements were made on products obtained from two vineyards aged 6 and 14 years from Douro region. The elemental content of vine-leaves and grapes was determined by Energy Dispersive X-Ray Fluorescence (EDXRF), while analysis of the must and wine was performed by Total Reflection X-ray Fluorescence (TXRF). Almost all elements present in wine and must samples did not exceed the recommended values found in literature for wine. Bromine was present in the 6 years old wine in a concentration 1 order of magnitude greater than what is usually detected. The Cu content in vine-leaves from the older vineyard was found to be extremely high probably due to excessive use of Cu-based fungicides to control vine downy mildew. Higher Cu content was also detected in grapes although not so pronounced. Concerning the wine a slightly higher level was detected on the older vineyard, even so not exceeding the recommended value.

  1. Determination of trace amounts of hexavalent chromium in drinking waters by dispersive microsolid-phase extraction using modified multiwalled carbon nanotubes combined with total reflection X-ray fluorescence spectrometry

    Science.gov (United States)

    Bahadir, Z.; Bulut, V. N.; Hidalgo, M.; Soylak, M.; Marguí, E.

    2015-05-01

    A methodology based on the combination of dispersive microsolid-phase extraction (DMSPE) with total reflection X-ray fluorescence (TXRF) spectrometry is proposed for the determination of hexavalent chromium in drinking waters. Multiwalled carbon nanotubes (MWCNTs) modified with the anionic exchanger tricaprylmethylammonium chloride (Aliquat 336) were used as solid sorbents. After the sorption process of Cr(VI) on the modified MWCNTs, the aqueous sample was separated by centrifugation and the loaded MWCNTs were suspended using a small volume of an internal standard solution and analyzed directly by a benchtop TXRF spectrometer, without any elution step. Parameters affecting the extraction process (pH and volume of the aqueous sample, amount of MWCNTs, extraction time) and TXRF analysis (volume of internal standard, volume of deposited suspension on the reflector, drying mode, and instrumental parameters) have been carefully evaluated to test the real capability of the developed methodology for the determination of Cr(VI) at trace levels. Using the best analytical conditions, it was found that the minimum Cr(VI) content that can be detected in an aqueous solution was 3 μg L- 1. This value is almost 20 times lower than the maximum hexavalent chromium content permissible in drinking waters, according to the World Health Organization (WHO). Recoveries for spiked tap and mineral water samples were, in most cases, in the range of 101-108% which demonstrates the suitability of the TXRF methodology for monitoring Cr(VI) at trace levels in drinking water samples.

  2. Quantitative determination on heavy metals in different stages of wine production by Total Reflection X-ray Fluorescence and Energy Dispersive X-ray Fluorescence: Comparison on two vineyards

    International Nuclear Information System (INIS)

    The purpose of this study is to determine the elemental content, namely heavy metals, of samples of vine-leaves, grapes must and wine. In order to assess the influence of the vineyard age on the elemental content throughout the several stages of wine production, elemental determinations of trace elements were made on products obtained from two vineyards aged 6 and 14 years from Douro region. The elemental content of vine-leaves and grapes was determined by Energy Dispersive X-Ray Fluorescence (EDXRF), while analysis of the must and wine was performed by Total Reflection X-ray Fluorescence (TXRF). Almost all elements present in wine and must samples did not exceed the recommended values found in literature for wine. Bromine was present in the 6 years old wine in a concentration 1 order of magnitude greater than what is usually detected. The Cu content in vine-leaves from the older vineyard was found to be extremely high probably due to excessive use of Cu-based fungicides to control vine downy mildew. Higher Cu content was also detected in grapes although not so pronounced. Concerning the wine a slightly higher level was detected on the older vineyard, even so not exceeding the recommended value.

  3. Evaluation of water and sediment of the Graminha and Aguas da Serra streams in the city of Limeira (Sp-Brazil) by Synchrotron Radiation Total Reflection X-ray Fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Silvana [University of Campinas, School of Civil Engineering, Architecture and Urban Design, P. O. Box 602, Zip Code 13083-852, Campinas, SP (Brazil)], E-mail: silvana@fec.unicamp.br; Fazza, Elizete Vieira [University of Campinas, School of Civil Engineering, Architecture and Urban Design, P. O. Box 602, Zip Code 13083-852, Campinas, SP (Brazil)], E-mail: fazzaelizete@yahoo.com

    2008-12-15

    The city of Limeira is located in the state of Sao Paulo, Brazil and has the second largest economy and demographic growth of the state. It comprises an expressive economy with industries in several productive sectors. The source of the Graminha and Aguas da Serra streams is located within the Limeira urban zone. The streams cross part of the rural zone and unite by draining into the Piracicaba River. It is possible that these basins suffer or have already suffered the impacts of environmental pollution caused by anthropogenic factors. Since the city has galvanization industries for the production of precious and semi-precious jewels as well as imitation jewelry, the concentration descriptions and interpretations of heavy metals in waters and sediments indicate anthropogenic influence and the dumping of these compounds into the Piracicaba River. The Synchrotron Radiation Total Reflection X-Ray Fluorescence (SR-TXRF) was used for determining the metals. All measurements were performed using a white beam of synchrotron radiation for excitation and a Ge hyperpure detector. Detection limits for water samples were 0.04 {mu}g L{sup -1} and in sediment samples 0.03 {mu}g g{sup -1} for Cu and Zn elements. In the water samples, concentrations higher than permissible as established by the Brazilian legislation (CONAMA) for Al, Fe, Zn, Cr, Ni, Cu and Pb, were observed. For sediment samples, values higher than quality reference values defined by the Brazilian legislation (CETESB) were verified for Cr, Zn, Cu, Ni and Pb.

  4. Total protein

    Science.gov (United States)

    The total protein test measures the total amount of two classes of proteins found in the fluid portion of your ... nutritional problems, kidney disease or liver disease . If total protein is abnormal, you will need to have more ...

  5. Total protein

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003483.htm Total protein To use the sharing features on this page, please enable JavaScript. The total protein test measures the total amount of two classes ...

  6. Green approach for ultratrace determination of divalent metal ions and arsenic species using total-reflection X-ray fluorescence spectrometry and mercapto-modified graphene oxide nanosheets as a novel adsorbent.

    Science.gov (United States)

    Sitko, Rafal; Janik, Paulina; Zawisza, Beata; Talik, Ewa; Margui, Eva; Queralt, Ignasi

    2015-03-17

    A new method based on dispersive microsolid phase extraction (DMSPE) and total-reflection X-ray fluorescence spectrometry (TXRF) is proposed for multielemental ultratrace determination of heavy metal ions and arsenic species. In the developed methodology, the crucial issue is a novel adsorbent synthesized by grafting 3-mercaptopropyl trimethoxysilane on a graphene oxide (GO) surface. Mercapto-modified graphene oxide (GO-SH) can be applied in quantitative adsorption of cobalt, nickel, copper, cadmium, and lead ions. Moreover, GO-SH demonstrates selectivity toward arsenite in the presence of arsenate. Due to such features of GO-SH nanosheets as wrinkled structure and excellent dispersibility in water, GO-SH seems to be ideal for fast and simple preconcentration and determination of heavy metal ions using methodology based on DMSPE and TXRF measurement. The suspension of GO-SH was injected into an analyzed water sample; after filtration, the GO-SH nanosheets with adsorbed metal ions were redispersed in a small volume of internal standard solution and deposited onto a quartz reflector. The high enrichment factor of 150 allows obtaining detection limits of 0.11, 0.078, 0.079, 0.064, 0.054, and 0.083 ng mL(-1) for Co(II), Ni(II), Cu(II), As(III), Cd(II), and Pb(II), respectively. Such low detection limits can be obtained using a benchtop TXRF system without cooling media and gas consumption. The method is suitable for the analysis of water, including high salinity samples difficult to analyze using other spectroscopy techniques. Moreover, GO-SH can be applied to the arsenic speciation due to its selectivity toward arsenite. PMID:25707847

  7. A novel vacuum spectrometer for total reflection x-ray fluorescence analysis with two exchangeable low power x-ray sources for the analysis of low, medium, and high Z elements in sequence

    Energy Technology Data Exchange (ETDEWEB)

    Wobrauschek, P., E-mail: wobi@ati.ac.at; Prost, J.; Ingerle, D.; Kregsamer, P.; Streli, C. [Atominstitut, TU Wien, Stadionallee 2, 1020 Vienna (Austria); Misra, N. L. [Fuel Chemistry Division, Bhabha Atomic Research Centre (BARC), Mumbai 400085 (India)

    2015-08-15

    The extension of the detectable elemental range with Total Reflection X-ray Fluorescence (TXRF) analysis is a challenging task. In this paper, it is demonstrated how a TXRF spectrometer is modified to analyze elements from carbon to uranium. Based on the existing design of a vacuum TXRF spectrometer with a 12 specimen sample changer, the following components were renewed: the silicon drift detector with 20 mm{sup 2} active area and having a special ultra-thin polymer window allowing the detection of elements from carbon upwards. Two exchangeable X-ray sources guarantee the efficient excitation of both low and high Z elements. These X-ray sources were two light-weighted easily mountable 35 W air-cooled low-power tubes with Cr and Rh anodes, respectively. The air cooled tubes and the Peltier-cooled detector allowed to construct a transportable tabletop spectrometer with compact dimensions, as neither liquid nitrogen cooling for the detector nor a water cooling circuit and a bulky high voltage generator for the X-ray tubes are required. Due to the excellent background conditions as a result of the TXRF geometry, detection limits of 150 ng for C, 12 ng for F, and 3.3 ng for Na have been obtained using Cr excitation in vacuum. For Rh excitation, the detection limits of 90 pg could be achieved for Sr. Taking 10 to 20 μl of sample volume, extrapolated detection limits in the ng/g (ppb) range are resulting in terms of concentration.

  8. A novel vacuum spectrometer for total reflection x-ray fluorescence analysis with two exchangeable low power x-ray sources for the analysis of low, medium, and high Z elements in sequence

    International Nuclear Information System (INIS)

    The extension of the detectable elemental range with Total Reflection X-ray Fluorescence (TXRF) analysis is a challenging task. In this paper, it is demonstrated how a TXRF spectrometer is modified to analyze elements from carbon to uranium. Based on the existing design of a vacuum TXRF spectrometer with a 12 specimen sample changer, the following components were renewed: the silicon drift detector with 20 mm2 active area and having a special ultra-thin polymer window allowing the detection of elements from carbon upwards. Two exchangeable X-ray sources guarantee the efficient excitation of both low and high Z elements. These X-ray sources were two light-weighted easily mountable 35 W air-cooled low-power tubes with Cr and Rh anodes, respectively. The air cooled tubes and the Peltier-cooled detector allowed to construct a transportable tabletop spectrometer with compact dimensions, as neither liquid nitrogen cooling for the detector nor a water cooling circuit and a bulky high voltage generator for the X-ray tubes are required. Due to the excellent background conditions as a result of the TXRF geometry, detection limits of 150 ng for C, 12 ng for F, and 3.3 ng for Na have been obtained using Cr excitation in vacuum. For Rh excitation, the detection limits of 90 pg could be achieved for Sr. Taking 10 to 20 μl of sample volume, extrapolated detection limits in the ng/g (ppb) range are resulting in terms of concentration

  9. Determination of trace amounts of hexavalent chromium in drinking waters by dispersive microsolid-phase extraction using modified multiwalled carbon nanotubes combined with total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    A methodology based on the combination of dispersive microsolid-phase extraction (DMSPE) with total reflection X-ray fluorescence (TXRF) spectrometry is proposed for the determination of hexavalent chromium in drinking waters. Multiwalled carbon nanotubes (MWCNTs) modified with the anionic exchanger tricaprylmethylammonium chloride (Aliquat 336) were used as solid sorbents. After the sorption process of Cr(VI) on the modified MWCNTs, the aqueous sample was separated by centrifugation and the loaded MWCNTs were suspended using a small volume of an internal standard solution and analyzed directly by a benchtop TXRF spectrometer, without any elution step. Parameters affecting the extraction process (pH and volume of the aqueous sample, amount of MWCNTs, extraction time) and TXRF analysis (volume of internal standard, volume of deposited suspension on the reflector, drying mode, and instrumental parameters) have been carefully evaluated to test the real capability of the developed methodology for the determination of Cr(VI) at trace levels. Using the best analytical conditions, it was found that the minimum Cr(VI) content that can be detected in an aqueous solution was 3 μg L−1. This value is almost 20 times lower than the maximum hexavalent chromium content permissible in drinking waters, according to the World Health Organization (WHO). Recoveries for spiked tap and mineral water samples were, in most cases, in the range of 101–108% which demonstrates the suitability of the TXRF methodology for monitoring Cr(VI) at trace levels in drinking water samples. - Highlights: • A method using DMSPE and TXRF is proposed for Cr(VI) determination in water. • CNTs modified with a commercial anionic exchanger are used for the DMSPE. • The detection limit for hexavalent chromium is 3 μg L−1. • Accuracy and precision are suitable for the analysis of tap and mineral waters

  10. Determination of trace amounts of hexavalent chromium in drinking waters by dispersive microsolid-phase extraction using modified multiwalled carbon nanotubes combined with total reflection X-ray fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Bahadir, Z. [Department of Chemistry, Giresun University, Giresun (Turkey); Bulut, V.N. [Macka Vocational School, Karadeniz Technical University, Macka, Trabzon (Turkey); Hidalgo, M. [Department of Chemistry, Faculty of Sciences, University of Girona, Girona (Spain); Soylak, M. [Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri (Turkey); Marguí, E., E-mail: eva.margui@udg.edu [Department of Chemistry, Faculty of Sciences, University of Girona, Girona (Spain)

    2015-05-01

    A methodology based on the combination of dispersive microsolid-phase extraction (DMSPE) with total reflection X-ray fluorescence (TXRF) spectrometry is proposed for the determination of hexavalent chromium in drinking waters. Multiwalled carbon nanotubes (MWCNTs) modified with the anionic exchanger tricaprylmethylammonium chloride (Aliquat 336) were used as solid sorbents. After the sorption process of Cr(VI) on the modified MWCNTs, the aqueous sample was separated by centrifugation and the loaded MWCNTs were suspended using a small volume of an internal standard solution and analyzed directly by a benchtop TXRF spectrometer, without any elution step. Parameters affecting the extraction process (pH and volume of the aqueous sample, amount of MWCNTs, extraction time) and TXRF analysis (volume of internal standard, volume of deposited suspension on the reflector, drying mode, and instrumental parameters) have been carefully evaluated to test the real capability of the developed methodology for the determination of Cr(VI) at trace levels. Using the best analytical conditions, it was found that the minimum Cr(VI) content that can be detected in an aqueous solution was 3 μg L{sup −1}. This value is almost 20 times lower than the maximum hexavalent chromium content permissible in drinking waters, according to the World Health Organization (WHO). Recoveries for spiked tap and mineral water samples were, in most cases, in the range of 101–108% which demonstrates the suitability of the TXRF methodology for monitoring Cr(VI) at trace levels in drinking water samples. - Highlights: • A method using DMSPE and TXRF is proposed for Cr(VI) determination in water. • CNTs modified with a commercial anionic exchanger are used for the DMSPE. • The detection limit for hexavalent chromium is 3 μg L{sup −1}. • Accuracy and precision are suitable for the analysis of tap and mineral waters.

  11. Landing gear noise attenuation

    Science.gov (United States)

    Moe, Jeffrey W. (Inventor); Whitmire, Julia (Inventor); Kwan, Hwa-Wan (Inventor); Abeysinghe, Amal (Inventor)

    2011-01-01

    A landing gear noise attenuator mitigates noise generated by airframe deployable landing gear. The noise attenuator can have a first position when the landing gear is in its deployed or down position, and a second position when the landing gear is in its up or stowed position. The noise attenuator may be an inflatable fairing that does not compromise limited space constraints associated with landing gear retraction and stowage. A truck fairing mounted under a truck beam can have a compliant edge to allow for non-destructive impingement of a deflected fire during certain conditions.

  12. RADIO FREQUENCY ATTENUATOR

    Science.gov (United States)

    Giordano, S.

    1963-11-12

    A high peak power level r-f attenuator that is readily and easily insertable along a coaxial cable having an inner conductor and an outer annular conductor without breaking the ends thereof is presented. Spaced first and second flares in the outer conductor face each other with a slidable cylindrical outer conductor portion therebetween. Dielectric means, such as water, contact the cable between the flares to attenuate the radio-frequency energy received thereby. The cylindrical outer conductor portion is slidable to adjust the voltage standing wave ratio to a low level, and one of the flares is slidable to adjust the attenuation level. An integral dielectric container is also provided. (AFC)

  13. Flight solar calibrations using the Mirror Attenuator Mosaic (MAM): Low scattering mirror

    Science.gov (United States)

    Lee, Robert B., III

    1992-01-01

    Measurements of solar radiances reflected from the mirror attenuator mosaic (MAM) were used to calibrate the shortwave portions of the Earth Radiation Budget Experiment (ERBE) thermistor bolometer scanning radiometers. The MAM is basically a low scattering mirror which has been used to attenuate and reflect solar radiation into the fields of view for the broadband shortwave (0.2 to 5 micrometers) and total (0.2 to 50.0+ micrometers) ERBE scanning radiometers. The MAM assembly consists of a tightly packed array of aluminum, 0.3175-cm diameter concave spherical mirrors and field of view limiting baffles. The spherical mirrors are masked by a copper plate, electro-plated with black chrome. Perforations (0.14 centimeter in diameter) in the copper plate serve as apertures for the mirrors. Black anodized aluminum baffles limit the MAM clear field of view to 7.1 degrees. The MAM assemblies are located on the Earth Radiation Budget Satellite (ERBS) and on the National Oceanic and Atmospheric Administration NOAA-9 and NOAA-10 spacecraft. The 1984-1985 ERBS and 1985-1986 NOAA-9 solar calibration datasets are presented. Analyses of the calibrations indicate that the MAM exhibited no detectable degradation in its reflectance properties and that the gains of the shortwave scanners did not change. The stability of the shortwave radiometers indicates that the transmission of the Suprasil W1 filters did not degrade detectably when exposed to Earth/atmosphere-reflected solar radiation.

  14. Attenuator And Conditioner

    Science.gov (United States)

    Anderson, Gene R.; Armendariz, Marcelino G.; Carson, Richard F.; Bryan, Robert P.; Duckett, III, Edwin B.; Kemme, Shanalyn Adair; McCormick, Frederick B.; Peterson, David W.

    2006-04-04

    An apparatus and method of attenuating and/or conditioning optical energy for an optical transmitter, receiver or transceiver module is disclosed. An apparatus for attenuating the optical output of an optoelectronic connector including: a mounting surface; an array of optoelectronic devices having at least a first end; an array of optical elements having at least a first end; the first end of the array of optical elements optically aligned with the first end of the array of optoelectronic devices; an optical path extending from the first end of the array of optoelectronic devices and ending at a second end of the array of optical elements; and an attenuator in the optical path for attenuating the optical energy emitted from the array of optoelectronic devices. Alternatively, a conditioner may be adapted in the optical path for conditioning the optical energy emitted from the array of optoelectronic devices.

  15. Total algorithms

    NARCIS (Netherlands)

    Tel, G.

    1993-01-01

    We define the notion of total algorithms for networks of processes. A total algorithm enforces that a "decision" is taken by a subset of the processes, and that participation of all processes is required to reach this decision. Total algorithms are an important building block in the design of distri

  16. Reflection groups

    International Nuclear Information System (INIS)

    In 2005, PISA organised proactive meetings of reflection groups on involvement in decision making, expert culture and ethical aspects of radiation protection.All reflection group meetings address particular targeted audiences while the output publication in book form is put forward

  17. X-Ray Form Factor, Attenuation and Scattering Tables

    Science.gov (United States)

    SRD 66 X-Ray Form Factor, Attenuation and Scattering Tables (Web, free access)   This database collects tables and graphs of the form factors, the photoabsorption cross section, and the total attenuation coefficient for any element (Z <= 92).

  18. Elemental analysis of human amniotic fluid and placenta by total-reflection X-ray fluorescence and energy-dispersive X-ray fluorescence: child weight and maternal age dependence

    Science.gov (United States)

    Carvalho, M. L.; Custódio, P. J.; Reus, U.; Prange, A.

    2001-11-01

    This work is an attempt to evaluate the possible influence of the mother's age in trace element concentrations in human amniotic fluid and placenta and whether these concentrations are correlated to the weight of the newborn infants. Total-reflection X-ray fluorescence (TXRF) was used to analyze 16 amniotic fluid samples, and the placenta samples were analyzed by energy dispersive X-ray fluorescence (EDXRF). The whole samples were collected during delivery from healthy mothers and healthy infants and full-term pregnancies. According to the age of the mother, three different groups were considered: 20-25, 25-30 and 30-40 years old. Only two mothers were aged more than 35 years. The weight of the infants ranged from 2.56 to 4.05 kg and three groups were also considered: 2.5-3, 3-3.5 and 3.5-4 kg. The organic matrix of the amniotic fluid samples was removed by treatment with HNO 3 followed by oxygen plasma ashing. Yttrium was used as the internal standard for TXRF analysis. Placenta samples were lyophilized and analyzed by EDXRF without any chemical treatment. Very low levels of Ni and Sr were found in the amniotic fluid samples, and were independent of the age of the mother and weight of the child. Cr, Mn, Se and Pb were at the level of the detection limit. Zn, considered one of the key elements in neonatal health, was not significantly different in the samples analyzed; however, it was weakly related to birth weigh. The concentrations obtained ranged from 0.11 to 0.92 mg/l and 30 to 65 μg/g in amniotic fluid and placenta, respectively. The only two elements which seemed to be significantly correlated with mother's age and newborn weight were Ca and Fe for both types of sample: Ca levels were increased in heavier children and older mothers; however, Fe increased with increasing maternal age, but decreased for heavier babies. The same conclusions were obtained for placenta and amniotic fluid samples. Cu is closely associated with Fe in its function in the organism

  19. Quantifying Reflection

    DEFF Research Database (Denmark)

    Alcock, Gordon Lindsay

    2013-01-01

    This paper documents 1st semester student reflections on “learning to learn” in a team-based PBL environment with quantitative and qualitative student reflective feedback on the learning gains of 60 Architectural Technology and Construction Management students at VIA University College, Denmark. It...... contrasts the students’ self-assessment in a range of ‘product’ skills such as Revit, Structural Design, Mathematics of construction, Technical Installations; as well as ‘process’ competencies such as ‘Working in a team’, Sharing knowledge, Maintaining a portfolio and Reflecting ON learning and FOR learning...

  20. Radiofrequency attenuator and method

    Science.gov (United States)

    Warner, Benjamin P.; McCleskey, T. Mark; Burrell, Anthony K.; Agrawal, Anoop; Hall, Simon B.

    2009-11-10

    Radiofrequency attenuator and method. The attenuator includes a pair of transparent windows. A chamber between the windows is filled with molten salt. Preferred molten salts include quarternary ammonium cations and fluorine-containing anions such as tetrafluoroborate (BF.sub.4.sup.-), hexafluorophosphate (PF.sub.6.sup.-), hexafluoroarsenate (AsF.sub.6.sup.-), trifluoromethylsulfonate (CF.sub.3SO.sub.3.sup.-), bis(trifluoromethylsulfonyl)imide ((CF.sub.3SO.sub.2).sub.2N.sup.-), bis(perfluoroethylsulfonyl)imide ((CF.sub.3CF.sub.2SO.sub.2).sub.2N.sup.-) and tris(trifluoromethylsulfonyl)methide ((CF.sub.3SO.sub.2).sub.3 C.sup.-). Radicals or radical cations may be added to or electrochemically generated in the molten salt to enhance the RF attenuation.

  1. Study of RF Signal Attenuation of Human Heart

    OpenAIRE

    Kedar Nath Sahu; Challa Dhanunjaya Naidu; M. Satyam; K. Jaya Sankar

    2015-01-01

    A study of ultrawideband pulse propagation modeling through human body for all frequencies from 0.1 to 10.5 GHz is presented. Reflection coefficient and signal attenuation are computed from the model considering the variation of heart dimension with respect to time unlike a fixed dimension of heart used in earlier models. The performance of cardiac activity is studied from the change of signal attenuation. This estimation may help in the design of a noninvasive diagnostic system using ultrawi...

  2. Attenuation of the gamma rays in tissues

    International Nuclear Information System (INIS)

    The mass and lineal attenuation coefficient and of hepatic tissue, muscular, osseous and of brain before gamma rays of 10-3 to 105 MeV were calculated. For the case of the osseous tissue the calculation was made for the cartilage, the cortical tissue and the bone marrow. During the calculations the elementary composition of the tissues of human origin was used. The calculations include by separate the Photoelectric effect, the Compton scattering and the Pair production, as well as the total. For to establish a comparison with the attenuation capacities, the coefficients of the water, the aluminum and the lead also were calculated. The study was complemented measuring the attenuation coefficient of hepatic tissue of bovine before gamma rays of 0.662 MeV of a source of 137 Cs. The measurement was made through of an experiment of photons transmission through samples frozen of hepatic tissue and with a Geiger-Mueller detector. (Author)

  3. Pressure surge attenuator

    International Nuclear Information System (INIS)

    A pressure surge attenuation arrangement comprises crushable metal foam disposed adjacent regions adapted to be expanded by a pressure surge. In a pipe system such region consists of a thin walled inner pipe surrounded by a housing with crushable metal foam disposed in the space between the housing and the inner pipe. (author)

  4. Tritium Attenuation by Distillation

    International Nuclear Information System (INIS)

    The objective of this study was to determine how a 100 Area distillation system could be used to reduce to a satisfactory low value the tritium content of the dilute moderator produced in the 100 Area stills, and whether such a tritium attenuator would have sufficient capacity to process all this material before it is sent to the 400 Area for reprocessing

  5. Natural attenuation of herbicides

    DEFF Research Database (Denmark)

    Tuxen, Nina; Højberg, Anker Lajer; Broholm, Mette Martina;

    2002-01-01

    A field injection experiment in a sandy, aerobic aquifer showed that two phenoxy acids MCPP (mecoprop) and dichlorprop were degraded within I in downgradient of the injection wells after an apparent lag period. The plume development and microbial measurements indicated that microbial growth gover...... observations may be important for application of natural attenuation as a remedy in field scale systems....

  6. Reflective optics

    CERN Document Server

    Korsch, Dietrich

    1991-01-01

    This is the first book dedicated exclusively to all-reflective imaging systems. It is a teaching tool as well as a practical design tool for anyone who specializes in optics, particularly for those interested in telescopes, infrared, and grazing-incidence systems. The first part of the book describes a unified geometric optical theory of all-reflective imaging systems (from near-normal to grazing incidence) developed from basic principles. The second part discusses correction methods and a multitude of closed-form solutions of well-corrected systems, supplemented with many conventional and unc

  7. GPR measurements of attenuation in concrete

    International Nuclear Information System (INIS)

    Ground-penetrating radar (GPR) signals from concrete structures are affected by several phenomenon, including: (1) transmission and reflection coefficients at interfaces; (2) the radiation patterns of the antenna(s) being used; and (3) the material properties of concrete and any embedded objects. In this paper we investigate different schemes for determining the electromagnetic (EM) attenuation of concrete from measured signals obtained using commercially-available GPR equipment. We adapt procedures commonly used in ultrasonic inspections where one compares the relative strengths of two or more signals having different travel paths through the material of interest. After correcting for beam spread (i.e., diffraction), interface phenomena, and equipment amplification settings, any remaining signal differences are assumed to be due to attenuation thus allowing the attenuation coefficient (say, in dB of loss per inch of travel) to be estimated. We begin with a brief overview of our approach, and then discuss how diffraction corrections were determined for our two 1.6 GHz GPR antennas. We then present results of attenuation measurements for two types of concrete using both pulse/echo and pitch/catch measurement setups

  8. A compact rotary vane attenuator

    Science.gov (United States)

    Nixon, D. L.; Otosh, T. Y.; Stelzried, C. T.

    1969-01-01

    Rotary vane attenuator, when used as a front end attenuator, introduces an insertion loss that is proportional to the angle of rotation. New technique allows the construction of a shortened compact unit suitable for most installations.

  9. Photon attenuation by intensifying screens

    International Nuclear Information System (INIS)

    The photon attenuation by intensifying screens of different chemical composition has been determined. The attenuation of photons between 20 keV and 120 keV was measured by use of a multi-channel analyzer and a broad bremsstrahlung distribution. The attenuation by the intensifying screens was hereby determined simultaneously at many different monoenergetic photon energies. Experimentally determined attenuations were found to agree well with attenuation calculated from mass attenuation coefficients. The attenuation by the screens was also determined at various bremsstrahlung distributions, simulating those occurring behind the patient in various diagnostic X-ray examinations. The high attenuation in some of the intensifying screens form the basis for an analysis of the construction of asymmetric screen pairs. Single screen systems are suggested as a favourable alternative to thick screen pair systems. (Author)

  10. Variable CO2 laser attenuator. [for infrared wavelengths

    Science.gov (United States)

    Klein, B. J.; Degnan, J. J.; Walker, H. E.; Zagwodzki, T.

    1974-01-01

    An infrared wavelength variable attenuator based on contra-rotating germanium wedges is examined theoretically. The device redirects the paths of internal reflections associated with an optical flat to avoid closely spaced parallel beams at the output. Complementary wedges separated by an air gap compose an optical flat which, when combined with a masking arrangement, restricts unwanted reflections. A model of the device was built and experimentally evaluated. The results compare favorably with the dynamic range of attenuation of 2 to 50 db from theoretical calculations, and show a substantial reduction in the etalon effect associated with pairs of optical flats.

  11. Downhole pressure attenuation apparatus

    International Nuclear Information System (INIS)

    This patent describes a process for preventing damage to tool strings and other downhole equipment in a well caused by pressures produced during detonation of one or more downhole explosive devices. It comprises adding to a tool string at least one pressure attenuating apparatus for attenuating the peak pressure wave and quasi-static pressure pulse produced by the explosive devices, the pressure attenuating apparatus including an initially closed relief vent including tubing means supporting a plurality of charge port assemblies each including an explosive filled shaped charge and a prestressed disc, the shaped charges interconnected by a detonating cord, the amount of explosive in each shaped charge being sufficient to rupture its associated disc without damaging surrounding tubular bodies in the well, and a vent chamber defined by the tubing means and providing a liquid free volume, and opening the relief vent substantially contemporaneously with downhole explosive device detonation by detonating the shaped charges to rupture the discs of the charge port assemblies

  12. Flexible graphene based microwave attenuators.

    Science.gov (United States)

    Byun, Kisik; Ju Park, Yong; Ahn, Jong-Hyun; Min, Byung-Wook

    2015-02-01

    We demonstrate flexible 3 dB and 6 dB microwave attenuators using multilayer graphene grown by the chemical vapor deposition method. On the basis of the characterized results of multilayer graphene and graphene-Au ohmic contacts, the graphene attenuators are designed and measured. The flexible graphene-based attenuators have 3 dB and 6 dB attenuation with a return loss of less than -15 dB at higher than 5 GHz. The devices have shown durability in a bending cycling test of 100 times. The circuit model of the attenuator based on the characterized results matches the experimental results well. PMID:25590144

  13. Flexible graphene based microwave attenuators

    International Nuclear Information System (INIS)

    We demonstrate flexible 3 dB and 6 dB microwave attenuators using multilayer graphene grown by the chemical vapor deposition method. On the basis of the characterized results of multilayer graphene and graphene–Au ohmic contacts, the graphene attenuators are designed and measured. The flexible graphene-based attenuators have 3 dB and 6 dB attenuation with a return loss of less than −15 dB at higher than 5 GHz. The devices have shown durability in a bending cycling test of 100 times. The circuit model of the attenuator based on the characterized results matches the experimental results well. (paper)

  14. The attenuation of the periodic table

    International Nuclear Information System (INIS)

    Unique among models of nuclear structure, the face-centered-cubic (FCC) lattice model predicts the attenuation of the periodic table at Z < 110 and the impossibility of superheavy nuclei. The total binding energies of superheavy nuclei in the FCC model (109 < Z < 127) were calculated on the basis of parameters obtained from a least-squares best-fit for 914 nuclei (Z < 99). No indication of increased stability is found for any of the transuranic elements

  15. Action-related auditory ERP attenuation: Paradigms and hypotheses.

    Science.gov (United States)

    Horváth, János

    2015-11-11

    A number studies have shown that the auditory N1 event-related potential (ERP) is attenuated when elicited by self-induced or self-generated sounds. Because N1 is a correlate of auditory feature- and event-detection, it was generally assumed that N1-attenuation reflected the cancellation of auditory re-afference, enabled by the internal forward modeling of the predictable sensory consequences of the given action. Focusing on paradigms utilizing non-speech actions, the present review summarizes recent progress on action-related auditory attenuation. Following a critical analysis of the most widely used, contingent paradigm, two further hypotheses on the possible causes of action-related auditory ERP attenuation are presented. The attention hypotheses suggest that auditory ERP attenuation is brought about by a temporary division of attention between the action and the auditory stimulation. The pre-activation hypothesis suggests that the attenuation is caused by the activation of a sensory template during the initiation of the action, which interferes with the incoming stimulation. Although each hypothesis can account for a number of findings, none of them can accommodate the whole spectrum of results. It is suggested that a better understanding of auditory ERP attenuation phenomena could be achieved by systematic investigations of the types of actions, the degree of action-effect contingency, and the temporal characteristics of action-effect contingency representation-buildup and -deactivation. This article is part of a Special Issue entitled SI: Prediction and Attention. PMID:25843932

  16. Pulse transducer with artifact signal attenuator. [heart rate sensors

    Science.gov (United States)

    Cash, W. H., Jr.; Polhemus, J. T. (Inventor)

    1980-01-01

    An artifact signal attenuator for a pulse rate sensor is described. The circuit for attenuating background noise signals is connected with a pulse rate transducer which has a light source and a detector for light reflected from blood vessels of a living body. The heart signal provided consists of a modulated dc signal voltage indicative of pulse rate. The artifact signal resulting from light reflected from the skin of the body comprises both a constant dc signal voltage and a modulated dc signal voltage. The amplitude of the artifact signal is greater and the frequency less than that of the heart signal. The signal attenuator circuit includes an operational amplifier for canceling the artifact signal from the output signal of the transducer and has the capability of meeting packaging requirements for wrist-watch-size packages.

  17. Murine immunization by cesium-137 irradiation attenuated Schistosoma mansoni cercariae

    International Nuclear Information System (INIS)

    Cesium-137, becoming a more readily available ionizing gamma radiation source for laboratory use, was shown to effectively attenuate Schistosoma mansoni cercariae for vaccine production. In parallel comparison studies with the murine model, cesium-137 attenuated cercariae consistently afforded better protection than did the cobalt-60 prepared vaccine. Dose-response data indicated that the optimal total irradiation with cesium-137 was between 45 and 50 Krad

  18. Murine immunization by cesium-137 irradiation attenuated Schistosoma mansoni cercariae

    Energy Technology Data Exchange (ETDEWEB)

    Stek, M. Jr.; Minard, P.; Cruess, D.F.

    1984-06-01

    Cesium-137, becoming a more readily available ionizing gamma radiation source for laboratory use, was shown to effectively attenuate Schistosoma mansoni cercariae for vaccine production. In parallel comparison studies with the murine model, cesium-137 attenuated cercariae consistently afforded better protection than did the cobalt-60 prepared vaccine. Dose-response data indicated that the optimal total irradiation with cesium-137 was between 45 and 50 Krad.

  19. Monte Carlo simulation of diffuse attenuation coefficient in presence of non uniform profiles

    Digital Repository Service at National Institute of Oceanography (India)

    Desa, E.S.; Desai, R.G.P.; Desa, B.A.E.

    This paper presents a Monte Carlo simulation of the vertical depth structure of the downward attenuation coefficient (K sub(d)), and the irradiance reflectance (R) for a given profile of chlorophyll. The results are in quantitaive agreement...

  20. Inspiring Reflections

    DEFF Research Database (Denmark)

    Muchie, Mammo

    2011-01-01

    life is not free from fluctuations, cycles, disruptions, crises and destructions both human and ecological. Innovation research ought to position itself to address environmental, financial and economic crises. The third is innovation research for development by addressing not only poverty erdaication......A numberof Chris Freeman's colleagues were asked to reflect on what they thought describes his life and work in a few words. Some of the colleagues replied including former SPRU students that were taught or supervised by Chris Freeman. Their views on what they thought were Chris Freeman's defining...... contributions have been put together. There are a number of ways to continue Chris Freeman's legacy on innovation research. The first is to build in a critical tradition in the economics of innovation research by introducing fearlessly emancipatory epistemology. Second the economic system that dominates social...

  1. Ultrasonic Attenuation in Zircaloy-4

    International Nuclear Information System (INIS)

    In this work the relationship between Zircaloy-4 grain size and ultrasonic attenuation behavior was studied for longitudinal waves in the frequency range of 10-90 MHz. The attenuation was analyzed as a function of frequency for samples with different mechanical and heat treatments having recrystallized and Widmanstatten structures with different grain size. The attenuation behavior was analyzed by different scattering models, depending on grain size, wavelength and frequency

  2. Chopping-Wheel Optical Attenuator

    Science.gov (United States)

    Leviton, Douglas B.

    1988-01-01

    Star-shaped rotating chopping wheel provides adjustable time-averaged attenuation of narrow beam of light without changing length of optical path or spectral distribution of light. Duty cycle or attenuation factor of chopped beam controlled by adjusting radius at which beam intersects wheel. Attenuation factor independent of wavelength. Useful in systems in which chopping frequency above frequency-response limits of photodetectors receiving chopped light. Used in systems using synchronous detection with lock-in amplifiers.

  3. LINE-ABOVE-GROUND ATTENUATOR

    Science.gov (United States)

    Wilds, R.B.; Ames, J.R.

    1957-09-24

    The line-above-ground attenuator provides a continuously variable microwave attenuator for a coaxial line that is capable of high attenuation and low insertion loss. The device consists of a short section of the line-above- ground plane type transmission lime, a pair of identical rectangular slabs of lossy material like polytron, whose longitudinal axes are parallel to and indentically spaced away from either side of the line, and a geared mechanism to adjust amd maintain this spaced relationship. This device permits optimum fineness and accuracy of attenuator control which heretofore has been difficult to achieve.

  4. Fiber optic attenuator

    Science.gov (United States)

    Buzzetti, Mike F. (Inventor)

    1994-01-01

    A fiber optic attenuator of the invention is a mandrel structure through which a bundle of optical fibers is wrapped around in a complete circle. The mandrel structure includes a flexible cylindrical sheath through which the bundle passes. A set screw on the mandrel structure impacts one side of the sheath against two posts on the opposite side of the sheath. By rotating the screw, the sheath is deformed to extend partially between the two posts, bending the fiber optic bundle to a small radius controlled by rotating the set screw. Bending the fiber optic bundle to a small radius causes light in each optical fiber to be lost in the cladding, the amount depending upon the radius about which the bundle is bent.

  5. Reflecting on Čerenkov reflections

    Science.gov (United States)

    Fargion, D.; Gaug, M.; Oliva, P.

    2008-05-01

    particles whose escape in air and decay in flight may blaze Magic or reflect Čerenkov light at opposite far cloudy sky edges. Any collaboration (MAGIC,HESS,VERITAS) will be willing to dedicate cloudy time to UHECR physics since nothing else can be done in that time. These reflections may open a totally new UHECR spectroscopy while unveiling a rare, but loud Tau Neutrino astronomy [10, 8].

  6. Studies of Scattering, Reflectivity, and Transmitivity in WBAN Channel: Feasibility of Using UWB

    Directory of Open Access Journals (Sweden)

    Md. Humaun Kabir

    2010-06-01

    Full Text Available The Wireless Personal Area Network (WPAN is one of the fledging paradigms that the next generation of wireless systems is sprouting towards. Among them, a more specific category is the Wireless Body Area Network (WBAN used for health monitoring. On the other hand, Ultra-Wideband (UWB comes with a number of desirable features at the physical layer for wireless communications. One big challenge in adoption of UWB in WBAN is the fact that signals get attenuated exponentially. Due to the intrinsic structural complexity in human body, electromagnetic waves show a profound variation during propagation through it. The reflection and transmission coefficients of human body are highly dependent upon the dielectric constants as well as upon the frequency. The difference in structural materials such as fat, muscles and blood essentially makes electromagnetic wave attenuation to be different along the way. Thus, a complete characterization of body channel is a challenging task. The connection between attenuation and frequency of the signal makes the investigation of UWB in WBAN an interesting proposition. In this paper, we study analytically the impact of body channels on electromagnetic signal propagation with reference to UWB. In the process, scattering, reflectivity and transmitivity have been addressed with analysis of approximate layer-wise modeling, and with numerical depictions. Pulses with Gaussian profile have been employed in our analysis. It shows that, under reasonable practical approximations, the human body channel can be modeled in layers so as to have the effects of total reflections or total transmissions in certain frequency bands. This could help decide such design issues as antenna characteristics of implant devices for WBAN employing UWB.

  7. Studies of scattering, reflectivity, and transmitivity in WBAN channel: feasibility of using UWB.

    Science.gov (United States)

    Kabir, Md Humaun; Ashrafuzzaman, Kazi; Chowdhury, M Sanaullah; Kwak, Kyung Sup

    2010-01-01

    The Wireless Personal Area Network (WPAN) is one of the fledging paradigms that the next generation of wireless systems is sprouting towards. Among them, a more specific category is the Wireless Body Area Network (WBAN) used for health monitoring. On the other hand, Ultra-Wideband (UWB) comes with a number of desirable features at the physical layer for wireless communications. One big challenge in adoption of UWB in WBAN is the fact that signals get attenuated exponentially. Due to the intrinsic structural complexity in human body, electromagnetic waves show a profound variation during propagation through it. The reflection and transmission coefficients of human body are highly dependent upon the dielectric constants as well as upon the frequency. The difference in structural materials such as fat, muscles and blood essentially makes electromagnetic wave attenuation to be different along the way. Thus, a complete characterization of body channel is a challenging task. The connection between attenuation and frequency of the signal makes the investigation of UWB in WBAN an interesting proposition. In this paper, we study analytically the impact of body channels on electromagnetic signal propagation with reference to UWB. In the process, scattering, reflectivity and transmitivity have been addressed with analysis of approximate layer-wise modeling, and with numerical depictions. Pulses with Gaussian profile have been employed in our analysis. It shows that, under reasonable practical approximations, the human body channel can be modeled in layers so as to have the effects of total reflections or total transmissions in certain frequency bands. This could help decide such design issues as antenna characteristics of implant devices for WBAN employing UWB. PMID:22219673

  8. PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients

    International Nuclear Information System (INIS)

    The CT data acquired in combined PET/CT studies provide a fast and essentially noiseless source for the correction of photon attenuation in PET emission data. To this end, the CT values relating to attenuation of photons in the range of 40-140 keV must be transformed into linear attenuation coefficients at the PET energy of 511 keV. As attenuation depends on photon energy and the absorbing material, an accurate theoretical relation cannot be devised. The transformation implemented in the Discovery LS PET/CT scanner (GE Medical Systems, Milwaukee, Wis.) uses a bilinear function based on the attenuation of water and cortical bone at the CT and PET energies. The purpose of this study was to compare this transformation with experimental CT values and corresponding PET attenuation coefficients. In 14 patients, quantitative PET attenuation maps were calculated from germanium-68 transmission scans, and resolution-matched CT images were generated. A total of 114 volumes of interest were defined and the average PET attenuation coefficients and CT values measured. From the CT values the predicted PET attenuation coefficients were calculated using the bilinear transformation. When the transformation was based on the narrow-beam attenuation coefficient of water at 511 keV (0.096 cm-1), the predicted attenuation coefficients were higher in soft tissue than the measured values. This bias was reduced by replacing 0.096 cm-1 in the transformation by the linear attenuation coefficient of 0.093 cm-1 obtained from germanium-68 transmission scans. An analysis of the corrected emission activities shows that the resulting transformation is essentially equivalent to the transmission-based attenuation correction for human tissue. For non-human material, however, it may assign inaccurate attenuation coefficients which will also affect the correction in neighbouring tissue. (orig.)

  9. Fracture diagnostics with tube wave reflection logs

    International Nuclear Information System (INIS)

    This paper reports on the Tube Wave Reflection Log (TWRL) which is acoustic logging method which provides information about the height, location and conductivity of hydraulically induced fractures behind perforated casing. The TWRL tool consists of a transmitter and closely spaced receiver. The transmitter is driven with a short, low frequency tone burst to generate long wavelength tube waves which are little attenuated in unperforated casing. They are partially reflected when they pass perforated intervals communicating with a hydraulically induced fracture. The tool listens for such reflections for 0.1 seconds following each excitation burst. As the tool is moved uphole at logging speed, the transmitter is excited at each foot of depth. VDL displays of the TWRL records provide reflection traces whose projections define the uppermost and lower-most perforations communicating with the fracture. The strength of the reflections depends on the ease of fluid flow into the fracture and thus, is an indicator of fracture conductivity

  10. A Reflective Look at Reflecting Teams

    Science.gov (United States)

    Pender, Rebecca L.; Stinchfield, Tracy

    2012-01-01

    This article reviewed existing literature and research on the reflecting team process. There is a dearth of empirical research that explores the reflecting team process and the outcome of counseling that uses reflecting teams. Implications of using reflecting teams for counselors, counselor educators, and clients will be discussed. A call for…

  11. Seismic attenuation in fractured media

    International Nuclear Information System (INIS)

    The prime objective of this paper is to quantitatively estimate seismic attenuation caused by fractures with different physical parameters. In seismic wave simulation, the fractured media are treated as the anisotropic media and fractures are represented by frequency-dependent elastic constants. Based on numerical experiments with three different parameters, namely viscosity, porosity and the Lamé parameters, this paper has the following observations. First, seismic attenuation is not affected by the viscosity within fractures, although it increases with the increase of porosity and decreases with the increase of the Lamé parameters within fractures. Among the latter two parameters, seismic attenuation is more sensitive to the Lamé parameters than to the porosity. Second, for the attenuation anisotropy, low frequencies have more anisotropic effect than high frequencies. For example, a 50 Hz wavefield has the strongest anisotropy effect if compared to 100 and 150 Hz wavefields. The attenuation anisotropy for low frequency (say 50 Hz) is more sensitive to the viscosity than the porosity and the Lamé parameters have the weakest effect among these three parameters. These observations suggest that low-frequency seismic attenuation, and especially the attenuation anisotropy in low frequency, would have great potential for fluid discrimination within fractured media. (paper)

  12. Hollow optical-fiber based infrared spectroscopy for measurement of blood glucose level by using multi-reflection prism.

    Science.gov (United States)

    Kino, Saiko; Omori, Suguru; Katagiri, Takashi; Matsuura, Yuji

    2016-02-01

    A mid-infrared attenuated total reflection (ATR) spectroscopy system employing hollow optical fibers and a trapezoidal multi-reflection ATR prism has been developed to measure blood glucose levels. Using a multi-reflection prism brought about higher sensitivity, and the flat and wide contact surface of the prism resulted in higher measurement reproducibility. An analysis of in vivo measurements of human inner lip mucosa revealed clear signatures of glucose in the difference spectra between ones taken during the fasting state and ones taken after ingestion of glucose solutions. A calibration plot based on the absorption peak at 1155 cm(-1) that originates from the pyranose ring structure of glucose gave measurement errors less than 20%. PMID:26977373

  13. Development of electrothermal actuation based planar variable optical attenuators (VOAs)

    International Nuclear Information System (INIS)

    Several sorts of MEMS (Microelectromechanical Systems) based have been demonstrated by using electrostatic actuation scheme up to date. The comb drive and parallel plate are the two most common electrostatic actuators that have been well studied in variable optical attenuator (VOA) applications. In addition to the known retro-reflection type of optical attenuation being realized by our new devices driven by electrothermal actuators in present study, a novel planar tilted mirror with rotational and translation moving capability is proposed by using electrothermal actuators as well. Using electrothermal actuators to provide said planar tilted mirror with rotational and translational displacement has granted us a more efficient way to perform the light attenuation for in-plane structure. The static and transient characteristics of devices operated at ambient room temperature environment show good repeatability and stability

  14. The new approach of polarimetric attenuation correction for improving radar quantitative precipitation estimation(QPE)

    Science.gov (United States)

    Gu, Ji-Young; Suk, Mi-Kyung; Nam, Kyung-Yeub; Ko, Jeong-Seok; Ryzhkov, Alexander

    2016-04-01

    To obtain high-quality radar quantitative precipitation estimation data, reliable radar calibration and efficient attenuation correction are very important. Because microwave radiation at shorter wavelength experiences strong attenuation in precipitation, accounting for this attenuation is the essential work at shorter wavelength radar. In this study, the performance of different attenuation/differential attenuation correction schemes at C band is tested for two strong rain events which occurred in central Oklahoma. And also, a new attenuation correction scheme (combination of self-consistency and hot-spot concept methodology) that separates relative contributions of strong convective cells and the rest of the storm to the path-integrated total and differential attenuation is among the algorithms explored. A quantitative use of weather radar measurement such as rainfall estimation relies on the reliable attenuation correction. We examined the impact of attenuation correction on estimates of rainfall in heavy rain events by using cross-checking with S-band radar measurements which are much less affected by attenuation and compared the storm rain totals obtained from the corrected Z and KDP and rain gages in these cases. This new approach can be utilized at shorter wavelength radars efficiently. Therefore, it is very useful to Weather Radar Center of Korea Meteorological Administration preparing X-band research dual Pol radar network.

  15. Guiding light by and beyond the total internal reflection mechanism

    NARCIS (Netherlands)

    Uranus, Henri Putra

    2005-01-01

    This thesis reports a series of techniques the author has developed to model various waveguiding structures, including the conventional planar and channel waveguides working by, and the advanced structures working beyond the TIR mechanism. Hence, this thesis contains both the methods and their appli

  16. Utilization of ilmenite/epoxy composite for neutrons and gamma rays attenuation

    International Nuclear Information System (INIS)

    This work deals with the study of ilmenite/epoxy composite as an injecting mortar for cracks developed in biological concrete shields, as well as, neutrons and gamma rays attenuation. Effects of the particle size on the mechanical strengths have been studied for epoxy resin filled with crushed ilmenite with different maximum particle sizes ranging from 32 to 500 μm. Thermal neutrons and gamma rays attenuation in ilmenite/epoxy composites with 75 and 80 wt.% of ilmenite concentration have been investigated. The total mass attenuation coefficients μ/ρ (cm2 g-1) of gamma ray for five ilmenite/epoxy composites have been calculated using the XCOM program (version 3.1) at energies from 10 keV to 100 MeV. Also, the total mass attenuation coefficients (μ/ρ) have estimated based on the measured total linear attenuation coefficients (μ) and compared with the calculated results where, a reasonable agreement was found

  17. Gamma and neutron attenuation behaviours of boron carbide–silicon carbide composites

    International Nuclear Information System (INIS)

    Highlights: • Gamma and neutron attenuation behaviours of B4C–SiC composites were investigated. • Increasing SiC ratio increases gamma attenuation behaviour of the B4C–SiC composites. • Increasing SiC ratio decrease attenuation behaviour of the B4C–SiC composites. • HVT values of the B4C–SiC composites were calculated for Cs-137, Co-60 and Pu–Be sources. • Experimental mass attenuation coefficient are compatible with theoretical (XCOM) values. - Abstract: In this study, the gamma and neutron attenuation behaviors of pure boron carbide and boron carbide–silicon carbide composites which include three different silicon carbide ratios (20%, 30%, and 40%) by volume were investigated against Cs-137, Co-60 gamma radioisotope sources and Pu–Be neutron source. Transmission technique was used in the experiments to investigate the gamma and neutron attenuation properties of the materials. Linear and mass attenuation coefficients of the samples were determined for 0.662 (Cs-137) and 1.25 MeV (Co-60) energetic gamma rays. In addition the total macroscopic cross-sections (∑T) were calculated for the materials against Pu–Be neutron source. Theoretical mass attenuation coefficients were calculated from XCOM computer code. The experimental and theoretical mass attenuation coefficients were compared and evaluated with each other. In addition half value thickness (HVT) calculations were carried out by using linear attenuation coefficients and total macroscopic cross-sections. The results showed that increasing silicon carbide ratio decreases HVTs against Cs-137 and Co-60 gamma radioisotope sources whereas increases HVTs against Pu–Be neutron source. The mass attenuation coefficients were compatible with the theoretical (XCOM) values. Increasing silicon carbide ratio in boron carbide–silicon carbide composites causes higher gamma attenuation and lower neutron attenuation values

  18. Design and performance analysis of total reflection-type secondary optics in concentrated photovoltaic module%应用于聚光光伏模组的全反射式二次聚光器的设计与性能分析

    Institute of Scientific and Technical Information of China (English)

    茹占强; 安志勇; 宋贺伦; 李望; 卢鑫; 于秋水; 张耀辉

    2011-01-01

    当前聚光光伏系统存在很多问题,比如跟踪器的跟踪精度偏低、聚焦光斑强度分布不均匀、聚焦光斑的形状跟太阳电池不匹配等,二次聚光器可以解决这些问题,从而提高高倍聚光光伏系统的光电转换效率.对高倍聚光光伏系统中的菲涅耳透镜和二次聚光器的聚光原理进行了简要分析,重点对全反射式二次聚光器进行了二维聚光的理论分析,并配合非成像光学的光线追迹方法,设计并加工了应用于某高倍聚光光伏系统的全反射式二次聚光器.对该二次聚光器的主要性能进行了仿真分析及评价,结果表明:该聚光器能提高高倍聚光光伏系统的整体性能.%At present, the high concentrated photovoltaic system has a lot of problems, for example,tracking accuracy of tracker is too low, focused spot irradiation distribution is ununiform, the shape of focused spot is different from the shape of solar cell, and so on.Secondary optics can improve the photoelectric conversion efficiency of the high concentrated photovoltaic system by solving these problems.The condensation principles of Fresnel lens and secondary optics were analyzed, in particularly twodimensional condensation theory about the total reflection-type secondary optics was analyzed.According to the results of theoretical analysis and the approach of ray trace of nonimaging optics, the total reflection-type secondary optics used in a high concentrated photovoltaic system was designed and processed.And some main performance of the secondary optics were analyzed and evaluated by simulation software.The conclusion is drawn that the total reflection-type secondary optics can improve the whole performance of the high concentrated photovoltaic system.

  19. IMPROVED RAIN ATTENUATION ESTIMATION BASED ON DSD AND RADAR DATA

    Czech Academy of Sciences Publication Activity Database

    Fišer, Ondřej

    Toulouse: Centre national d'études spatiales, 2006, ---. [CNES Workshop on Earth-Space Propagation /3./. Toulouse (FR), 25.09.2006-27.09.2006] R&D Projects: GA ČR GA102/04/2153 Institutional research plan: CEZ:AV0Z30420517 Keywords : rain attenuation estimation * radar reflectivity * MWS systems * satellite links * terrestlrial links Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  20. Baroreceptor activation attenuates attentional effects on pain-evoked potentials

    OpenAIRE

    Gray, Marcus A.; Minati, Ludovico; Paoletti, Giulia; Critchley, Hugo D.

    2010-01-01

    Focused attention typically enhances neural nociceptive responses, reflected electroencephalographically as increased amplitude of pain-evoked event-related potentials (ERPs). Additionally, pain-evoked ERPs are attenuated by hypertension and baroreceptor activity, through as yet unclear mechanisms. There is indirect evidence that these two effects may interact, suggesting that baroreceptor-related modulation of nociception is more than a low-level gating phenomenon. To address this hypothesis...