WorldWideScience

Sample records for astm standard guide

  1. Recommendations for fluorescence instrument qualification: the new ASTM Standard Guide.

    Science.gov (United States)

    DeRose, Paul C; Resch-Genger, Ute

    2010-03-01

    Aimed at improving quality assurance and quantitation for modern fluorescence techniques, ASTM International (ASTM) is about to release a Standard Guide for Fluorescence, reviewed here. The guide's main focus is on steady state fluorometry, for which available standards and instrument characterization procedures are discussed along with their purpose, suitability, and general instructions for use. These include the most relevant instrument properties needing qualification, such as linearity and spectral responsivity of the detection system, spectral irradiance reaching the sample, wavelength accuracy, sensitivity or limit of detection for an analyte, and day-to-day performance verification. With proper consideration of method-inherent requirements and limitations, many of these procedures and standards can be adapted to other fluorescence techniques. In addition, procedures for the determination of other relevant fluorometric quantities including fluorescence quantum yields and fluorescence lifetimes are briefly introduced. The guide is a clear and concise reference geared for users of fluorescence instrumentation at all levels of experience and is intended to aid in the ongoing standardization of fluorescence measurements.

  2. Deriving allowable properties of lumber : a practical guide for interpretation of ASTM standards

    Science.gov (United States)

    Alan Bendtsen; William L. Galligan

    1978-01-01

    The ASTM standards for establishing clear wood mechanical properties and for deriving structural grades and related allowable properties for visually graded lumber can be confusing and difficult for the uninitiated to interpret. This report provides a practical guide to using these standards for individuals not familiar with their application. Sample stress...

  3. Standard guide for high-resolution gamma-ray spectrometry of soil samples. ASTM standard

    International Nuclear Information System (INIS)

    1998-12-01

    This guide is under the jurisdiction of ASTM Committee C-26 on Nuclear Fuel Cycle and is the direct responsibility of Subcommittee C26.05 on Methods of Test. The current edition was approved on Jul. 10, 1998. It was published in December 1998. Copyright American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, West Conshohocken, PA, 19428, USA. This document is available from NTIS under license from ASTM

  4. 47 CFR 90.379 - ASTM E2213-03 DSRC Standard (ASTM-DSRC Standard).

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false ASTM E2213-03 DSRC Standard (ASTM-DSRC Standard... Communications Service (dsrcs) § 90.379 ASTM E2213-03 DSRC Standard (ASTM-DSRC Standard). Roadside Units... incorporated by reference: American Society for Testing and Materials (ASTM) E2213-03, “Standard Specification...

  5. ASTM STANDARD GUIDE FOR EVALUATING DISPOSAL OPTIONS FOR REUSE OF CONCRETE FROM NUCLEAR FACILITY DECOMMISSIONING

    International Nuclear Information System (INIS)

    Phillips, Ann Marie; Meservey, Richard H.

    2003-01-01

    Within the nuclear industry, many contaminated facilities that require decommissioning contain huge volumes of concrete. This concrete is generally disposed of as low-level waste at a high cost. Much of the concrete is lightly contaminated and could be reused as roadbed, fill material, or aggregate for new concrete, thus saving millions of dollars. However, because of the possibility of volumetric contamination and the lack of a method to evaluate the risks and costs of reusing concrete, reuse is rarely considered. To address this problem, Argonne National Laboratory-East (ANL-E) and the Idaho National Engineering and Environmental Laboratory teamed to write a ''concrete protocol'' to help evaluate the ramifications of reusing concrete within the U.S. Department of Energy (DOE). This document, titled the Protocol for Development of Authorized Release Limits for Concrete at U.S. Department of Energy Site (1) is based on ANL-E's previously developed scrap metal recycle protocols; on the 10-step method outlined in DOE's draft handbook, Controlling Release for Reuse or Recycle of Property Containing Residual Radioactive Material (2); and on DOE Order 4500.5, Radiation Protection of the Public and the Environment (3). The DOE concrete protocol was the basis for the ASTM Standard Guide for Evaluating Disposal Options for Concrete from Nuclear Facility Decommissioning, which was written to make the information available to a wider audience outside DOE. The resulting ASTM Standard Guide is a more concise version that can be used by the nuclear industry worldwide to evaluate the risks and costs of reusing concrete from nuclear facility decommissioning. The bulk of the ASTM Standard Guide focuses on evaluating the dose and cost for each disposal option. The user calculates these from the detailed formulas and tabulated data provided, then compares the dose and cost for each disposal option to select the best option that meets regulatory requirements. With this information

  6. Developing the (ASTM) voluntary consensus standards required to help implement the National Energy Plan

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    The recommended guide is the first American Society for Testing and Materials (ASTM) matrix in a family of such documents that combined, will help manage the development of the ASTM standards considered necessary to implement the current National Plan for Energy Research, Development, and Demonstration. It is expected that the guide will provide a framework for standards development to complement the nation's research and development in support of critical energy needs. The recommended guide identifies the energy-critical areas that are to be developed, the master ASTM recommended guide for developing the standards required to help the National Plan, the section in which each energy-critical area is covered, and the suggested ASTM lead committee responsible for each area (fossil, solar, geothermal, conservation, fusion, and fission reactor development). A comprehensive matrix to identify the areas of need for which ASTM standards will be required to help implement the National Energy Plan is also presented

  7. 46 CFR 163.003-3 - ASTM standard.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false ASTM standard. 163.003-3 Section 163.003-3 Shipping...: SPECIFICATIONS AND APPROVAL CONSTRUCTION Pilot Ladder § 163.003-3 ASTM standard. The following standard of the American Society for Testing and Materials (ASTM) is incorporated by reference into this subpart: ASTM D...

  8. ASTM reference radiologic digital image standards

    International Nuclear Information System (INIS)

    Wysnewski, R.; Wysnewski, D.

    1996-01-01

    ASTM Reference Radiographs have been essential in defining industry's material defect grade levels for many years. ASTM Reference Radiographs are used extensively as even the American Society for Metals Nondestructive Inspection and Quality Control Metals Handbook, Volume 11, eighth edition refers to ASTM Standard Reference Radiographs. The recently published E 1648 Standard Reference Radiographs for Examination of Aluminum Fusion Welds is a prime example of the on-going need for these references. To date, 14 Standard Reference Radiographs have been published to characterize material defects. Standard Reference Radiographs do not adequately address film-less radiologic methods. There are differences in mediums to content with. On a computer CRT defect indications appear differently when compared to indications viewed in a radiograph on a view box. Industry that uses non-film radiologic methods of inspection can be burdened with additional time and money developing internal standard reference radiologic images. These references may be deemed necessary for grading levels of product defects. Because there are no ASTM Standard Reference Radiologic data files for addressing this need in the industry, the authors of this paper suggested implementing a method for their creation under ASTM supervision. ASTM can assure continuity to those users making the transition from analog radiographic images to digital image data by swiftly addressing the requirements for reference digital image standards. The current status and possible future activities regarding a method to create digital data files is presented in this paper summary

  9. Standard Guide for Testing Polymer Matrix Composite Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This guide summarizes the application of ASTM standard test methods (and other supporting standards) to continuous-fiber reinforced polymer matrix composite materials. The most commonly used or most applicable ASTM standards are included, emphasizing use of standards of Committee D30 on Composite Materials. 1.2 This guide does not cover all possible standards that could apply to polymer matrix composites and restricts discussion to the documented scope. Commonly used but non-standard industry extensions of test method scopes, such as application of static test methods to fatigue testing, are not discussed. A more complete summary of general composite testing standards, including non-ASTM test methods, is included in the Composite Materials Handbook (MIL-HDBK-17). Additional specific recommendations for testing textile (fabric, braided) composites are contained in Guide D6856. 1.3 This guide does not specify a system of measurement; the systems specified within each of the referenced standards shall appl...

  10. Status on the selection and development of an embrittlement trend curve to use in ASTM standard guide E900

    International Nuclear Information System (INIS)

    Kirk, M.; Brian Hall, J.; Server, W.; Lucon, E.; Erickson, M.; Stoller, R.

    2015-01-01

    ASTM E900-07, Standard Guide for Predicting Radiation-Induced Transition Temperature Shift in Reactor Vessel Materials, includes an embrittlement trend curve. The trend curve can be used to predict the effect of neutron irradiation on the embrittlement of ferritic pressure vessel steels, as quantified by the shift in the Charpy V-Notch transition curve at 41 Joules of absorbed energy (ΔT 41J ). The current E900 trend curve was first adopted in the 2002 revision. In 2011 ASTM Subcommittee E10.02 undertook an extensive effort to evaluate the adequacy of the E900 trend curve for continued use. This paper summarizes the current status of this effort, which has produced a trend curve calibrated using a database of over 1800 ΔT 41J values from the light water reactor surveillance programs in thirteen countries. (authors)

  11. ASTM international workshop on standards and measurements for tissue engineering scaffolds.

    Science.gov (United States)

    Simon, Carl G; Yaszemski, Michael J; Ratcliffe, Anthony; Tomlins, Paul; Luginbuehl, Reto; Tesk, John A

    2015-07-01

    The "Workshop on Standards & Measurements for Tissue Engineering Scaffolds" was held on May 21, 2013 in Indianapolis, IN, and was sponsored by the ASTM International (ASTM). The purpose of the workshop was to identify the highest priority items for future standards work for scaffolds used in the development and manufacture of tissue engineered medical products (TEMPs). Eighteen speakers and 78 attendees met to assess current scaffold standards and to prioritize needs for future standards. A key finding was that the ASTM TEMPs subcommittees (F04.41-46) have many active "guide" documents for educational purposes, but few standard "test methods" or "practices." Overwhelmingly, the most clearly identified need was standards for measuring the structure of scaffolds, followed by standards for biological characterization, including in vitro testing, animal models and cell-material interactions. The third most pressing need was to develop standards for assessing the mechanical properties of scaffolds. Additional needs included standards for assessing scaffold degradation, clinical outcomes with scaffolds, effects of sterilization on scaffolds, scaffold composition, and drug release from scaffolds. Discussions highlighted the need for additional scaffold reference materials and the need to use them for measurement traceability. Workshop participants emphasized the need to promote the use of standards in scaffold fabrication, characterization, and commercialization. Finally, participants noted that standards would be more broadly accepted if their impact in the TEMPs community could be quantified. Many scaffold standard needs have been identified and focus is turning to generating these standards to support the use of scaffolds in TEMPs. © 2014 Wiley Periodicals, Inc.

  12. 47 CFR 95.1509 - ASTM E2213-03 DSRC Standard.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false ASTM E2213-03 DSRC Standard. 95.1509 Section 95... ASTM E2213-03 DSRC Standard. On-Board Units operating in the 5850-5925 MHz band shall comply with the... Materials (ASTM) E2213-03, Standard Specification for Telecommunications and Information Exchange Between...

  13. Summary: Update to ASTM guide E 1523 to charge control and charge referencing techniques in x-ray photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Baer, D.R.

    2005-01-01

    An updated version of the American Society for Testing and Materials (ASTM) guide E 1523 to the methods to charge control and charge referencing techniques in x-ray photoelectron spectroscopy has been released by ASTM [Annual Book of ASTM Standards Surface Analysis (American Society for Testing and Materials, West Conshohocken, PA, 2004), Vol. 03.06]. The guide is meant to acquaint x-ray photoelectron spectroscopy (XPS) users with the various charge control and charge referencing techniques that are and have been used in the acquisition and interpretation of XPS data from surfaces of insulating specimens. The current guide has been expanded to include new references as well as recommendations for reporting information on charge control and charge referencing. The previous version of the document had been published in 1997 [D. R. Baer and K. D. Bomben, J. Vac. Sci. Technol. A 16, 754 (1998)

  14. Annual Book of ASTM Standards, Part 23: Water; Atmospheric Analysis.

    Science.gov (United States)

    American Society for Testing and Materials, Philadelphia, PA.

    Standards for water and atmospheric analysis are compiled in this segment, Part 23, of the American Society for Testing and Materials (ASTM) annual book of standards. It contains all current formally approved ASTM standard and tentative test methods, definitions, recommended practices, proposed methods, classifications, and specifications. One…

  15. Mobile Robot and Mobile Manipulator Research Towards ASTM Standards Development.

    Science.gov (United States)

    Bostelman, Roger; Hong, Tsai; Legowik, Steven

    2016-01-01

    Performance standards for industrial mobile robots and mobile manipulators (robot arms onboard mobile robots) have only recently begun development. Low cost and standardized measurement techniques are needed to characterize system performance, compare different systems, and to determine if recalibration is required. This paper discusses work at the National Institute of Standards and Technology (NIST) and within the ASTM Committee F45 on Driverless Automatic Guided Industrial Vehicles. This includes standards for both terminology, F45.91, and for navigation performance test methods, F45.02. The paper defines terms that are being considered. Additionally, the paper describes navigation test methods that are near ballot and docking test methods being designed for consideration within F45.02. This includes the use of low cost artifacts that can provide alternatives to using relatively expensive measurement systems.

  16. ASTM Standards for Reactor Dosimetry and Pressure Vessel Surveillance

    International Nuclear Information System (INIS)

    GRIFFIN, PATRICK J.

    1999-01-01

    The ASTM standards provide guidance and instruction on how to field and interpret reactor dosimetry. They provide a roadmap towards understanding the current ''state-of-the-art'' in reactor dosimetry, as reflected by the technical community. The consensus basis to the ASTM standards assures the user of an unbiased presentation of technical procedures and interpretations of the measurements. Some insight into the types of standards and the way in which they are organized can assist one in using them in an expeditious manner. Two example are presented to help orient new users to the breadth and interrelationship between the ASTM nuclear metrology standards. One example involves the testing of a new ''widget'' to verify the radiation hardness. The second example involves quantifying the radiation damage at a pressure vessel critical weld location through surveillance dosimetry and calculation

  17. The USCG/environment Canada/ASTM standards development program

    International Nuclear Information System (INIS)

    Whittaker, H.

    1992-01-01

    Environment Canada's Emergencies Engineering Division (EED) has been charged, as a result of the Public Review Panel on Tanker Safety and Marine Emergency Response report, with increased R ampersand D in marine oil spills. This activity will, of necessity, include development of standards and guidelines for the testing and/or usage of oil spill cleanup equipment. The United States Coast Guard (USCG) has been charged with implementing the provisions of the Oil Pollution Act of 1990 (OPA-90), as it pertains to marine transportation vessels and facilities. Among the provisions are requirements for vessel and facility owners and operators to develop comprehensive response plans that specifically match response resources to spill removal requirements. Meeting the response plan provisions of OPA-90 requires common standards for testing, selecting and assigning resources to anticipated response needs and objectively evaluating response plans for adequacy. In August of 1991, the USCG OPA-90 office approached ASTM to determine the feasibility of developing standards through that organizations procedures. Meetings were then held between the OPA-90 staff and members of the ASTM Committee F-20 on Hazardous Substances and Oil Spill Response. An agreement was reached to commence standards development in the areas of: Barriers, Skimmers, Treating Agents, Pumps, Beach Clean-up, Sorbents, Bioremediation, In-situ Burning, Temporary Storage Devices, Communications, Remote Sensing. It was recognized that ASTM and other organizational standards existed in several of these areas, but there were those where none were known to exist. Standards development was, therefore, expected to be a complicated and time-consuming process. Both the USCG OPA-90 and EC/EED offices required standards to be developed quickly, without subverting the ASTM process. Mechanical containment and recovery was considered to be the primary area of concern for both groups

  18. Comparisons of ASTM standards cited in the NRC standard review plan, NUREG-0800 and related documents

    International Nuclear Information System (INIS)

    Ankrum, A.R.; Bohlander, K.L.; Gilbert, E.R.; Pawlowski, R.A.; Spiesman, J.B.

    1995-10-01

    This report provides the results of comparisons of the cited and latest versions of ASTM standards cited in the NRC Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants (NUREG 0800) and related documents. The comparisons were performed by Battelle Pacific Northwest Laboratories in support of the NRC's Standard Review Plan Update and Development Program. Significant changes to the standards, from the cited version to the latest version, are described and discussed in a tabular format for each standard. Recommendations for updating each citation in the Standard Review Plan are presented. Technical considerations and suggested changes are included for related regulatory documents (i.e., Regulatory Guides and the Code of Federal Regulations) citing the standard. The results and recommendations presented in this document have not been subjected to NRC staff review

  19. ASTM standards associated with PWR and BWR power plant licensing, operation and surveillance

    International Nuclear Information System (INIS)

    McElroy, W.N.; McElroy, R.J.; Gold, R.; Lippincott, E.P.; Lowe, A.L. Jr.

    1994-01-01

    This paper considers ASTM Standards that are available, under revision, and are being considered in support of Pressurized Water Reactor (PWR) and Boiling Water Reactor (BWR) Nuclear Power Plant (NPP) licensing, regulation, operation, surveillance and life attainment. The current activities of ASTM Committee E10 and its Subcommittees E10.02 and current activities of ASTM Committee E10 and its Subcommittees E10.02 and E10.05 and their Task Groups (TG) are described. A very important aspect of these efforts is the preparation, revision, and balloting of standards identified in the ASTM E706 Standard on Master Matrix for Light Water Reactor (LWR) Pressure Vessel (PV) Surveillance Standards. The current version (E706-87) of the Master Matrix identifies 21 ASTM LWR physics-dosimetry-metallurgy standards for Reactor Pressure Vessel (RPV) and Support Structure (SS) surveillance programs, whereas, for the next revision 34 standards are identified. The need for national and international coordination of Standards Technology Development, Transfer and Training (STDTT) is considered in this and other Symposium papers that address specific standards related physics-dosimetry-metallurgy issues. 69 refs

  20. Fretting-corrosion at the modular tapers interface: Inspection of standard ASTM F1875-98.

    Science.gov (United States)

    Bingley, Rachel; Martin, Alan; Manfredi, Olivia; Nejadhamzeeigilani, Mahdiyar; Oladokun, Abimbola; Beadling, Andrew Robert; Siddiqui, Sohail; Anderson, James; Thompson, Jonathan; Neville, Anne; Bryant, Michael

    2018-05-01

    Interest in the degradation mechanisms at the modular tapers interfaces has been renewed due to increased reported cases of adverse reactions to metal debris and the appearance of wear and corrosion at the modular tapers interfaces at revision. Over the past two decades, a lot of research has been expended to understand the degradation mechanisms, with two primary implant loading procedures and orientations used consistently across the literature. ASTM F1875-98 is often used as a guide to understand and benchmark the tribocorrosion processes occurring within the modular tapers interface. This article presents a comparison of the two methods outlined in ASTM F1875-98 as well as a critique of the standard considering the current paradigm in pre-clinical assessment of modular tapers.

  1. Method for Estimating Evaporative Potential (IM/CLO) from ASTM Standard Single Wind Velocity Measures

    Science.gov (United States)

    2016-08-10

    IM/CLO) FROM ASTM STANDARD SINGLE WIND VELOCITY MEASURES DISCLAIMER The opinions or assertions contained herein are the private views of the...USARIEM TECHNICAL REPORT T16-14 METHOD FOR ESTIMATING EVAPORATIVE POTENTIAL (IM/CLO) FROM ASTM STANDARD SINGLE WIND VELOCITY... ASTM STANDARD SINGLE WIND VELOCITY MEASURES Adam W. Potter Biophysics and Biomedical Modeling Division U.S. Army Research Institute of Environmental

  2. ASTM International Workshop on Standards & Measurements for Tissue Engineering Scaffolds

    Science.gov (United States)

    Simon, Carl G.; Yaszemski, Michael J.; Ratcliffe, Anthony; Tomlins, Paul; Luginbuehl, Reto; Tesk, John A.

    2016-01-01

    The “Workshop on Standards & Measurements for Tissue Engineering Scaffolds” was held on May 21, 2013 in Indianapolis, IN and was sponsored by the ASTM International (ASTM). The purpose of the workshop was to identify the highest priority items for future standards work for scaffolds used in the development and manufacture of tissue engineered medical products (TEMPs). Eighteen speakers and 78 attendees met to assess current scaffold standards and to prioritize needs for future standards. A key finding was that the ASTM TEMPs subcommittees (F04.41-46) have many active “guide” documents for educational purposes, but that few standard “test methods” or “practices” have been published. Overwhelmingly, the most clearly identified need was standards for measuring the structure of scaffolds, followed by standards for biological characterization, including in vitro testing, animal models and cell-material interactions. The third most pressing need was to develop standards for assessing the mechanical properties of scaffolds. Additional needs included standards for assessing scaffold degradation, clinical outcomes with scaffolds, effects of sterilization on scaffolds, scaffold composition and drug release from scaffolds. Discussions also highlighted the need for additional scaffold reference materials and the need to use them for measurement traceability. Finally, dialogue emphasized the needs to promote the use of standards in scaffold fabrication, characterization, and commercialization and to assess the use and impact of standards in the TEMPs community. Many scaffold standard needs have been identified and focus should now turn to generating these standards to support the use of scaffolds in TEMPs. PMID:25220952

  3. ASTM standards for fire debris analysis: a review.

    Science.gov (United States)

    Stauffer, Eric; Lentini, John J

    2003-03-12

    The American Society for Testing and Materials (ASTM) recently updated its standards E 1387 and E 1618 for the analysis of fire debris. The changes in the classification of ignitable liquids are presented in this review. Furthermore, a new standard on extraction of fire debris with solid phase microextraction (SPME) was released. Advantages and drawbacks of this technique are presented and discussed. Also, the standard on cleanup by acid stripping has not been reapproved. Fire debris analysts that use the standards should be aware of these changes.

  4. 77 FR 10358 - Acceptance of ASTM F963-11 as a Mandatory Consumer Product Safety Standard

    Science.gov (United States)

    2012-02-22

    ... CONSUMER PRODUCT SAFETY COMMISSION 16 CFR Chapter II Acceptance of ASTM F963-11 as a Mandatory... have accepted the revised ASTM F963-11 standard titled, Standard Consumer Safety Specifications for Toy Safety. Pursuant to section 106 of the Consumer Product Safety Improvement Act of 2008, ASTM F963-11 will...

  5. ASTM Committee C28: International Standards for Properties and Performance of Advanced Ceramics-Three Decades of High-Quality, Technically-Rigorous Normalization

    Science.gov (United States)

    Jenkins, Michael G.; Salem, Jonathan A.

    2016-01-01

    Physical and mechanical properties and performance of advanced ceramics and glasses are difficult to measure correctly without the proper techniques. For over three decades, ASTM Committee C28 on Advanced Ceramics, has developed high-quality, technically-rigorous, full-consensus standards (e.g., test methods, practices, guides, terminology) to measure properties and performance of monolithic and composite ceramics that may be applied to glasses in some cases. These standards contain testing particulars for many mechanical, physical, thermal, properties and performance of these materials. As a result these standards are used to generate accurate, reliable, repeatable and complete data. Within Committee C28, users, producers, researchers, designers, academicians, etc. have written, continually updated, and validated through round-robin test programs, 50 standards since the Committee's founding in 1986. This paper provides a detailed retrospective of the 30 years of ASTM Committee C28 including a graphical pictogram listing of C28 standards along with examples of the tangible benefits of standards for advanced ceramics to demonstrate their practical applications.

  6. ASTM Committee C28: International Standards for Properties and Performance of Advanced Ceramics, Three Decades of High-quality, Technically-rigorous Normalization

    Science.gov (United States)

    Jenkins, Michael G.; Salem, Jonathan A.

    2016-01-01

    Physical and mechanical properties and performance of advanced ceramics and glasses are difficult to measure correctly without the proper techniques. For over three decades, ASTM Committee C28 on Advanced Ceramics, has developed high quality, rigorous, full-consensus standards (e.g., test methods, practices, guides, terminology) to measure properties and performance of monolithic and composite ceramics that may be applied to glasses in some cases. These standards testing particulars for many mechanical, physical, thermal, properties and performance of these materials. As a result these standards provide accurate, reliable, repeatable and complete data. Within Committee C28 users, producers, researchers, designers, academicians, etc. have written, continually updated, and validated through round-robin test programs, nearly 50 standards since the Committees founding in 1986. This paper provides a retrospective review of the 30 years of ASTM Committee C28 including a graphical pictogram listing of C28 standards along with examples of the tangible benefits of advanced ceramics standards to demonstrate their practical applications.

  7. Standardization work by ASTM and DIN concerning test methods for metallic materials - comparative assessment with regard for practice

    International Nuclear Information System (INIS)

    Gerischer, K.

    1986-01-01

    The article explains the significant role of ASTM and marks out basic elements of the specification system of ASTM standards. Usefulness in practice is taken as the main criterion for the subsequent comparison of ASTM or DIN activities and procedures, and results, for standardization in the field of test methods for metallic materials. The main differences are shown to exist with regard to tropicality of test standards, presentation of useful information and background knowledge, and importance attached to formal questions. ASTM standardization work is shown to be more up-to-date, contain more information, and to be less concerned with formal matters. A closer cooperation between ASTM and DIN is strongly recommended. (orig.) [de

  8. Standard Guide for Preparing Characterization Plans for Decommissioning Nuclear Facilities

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This standard guide applies to developing nuclear facility characterization plans to define the type, magnitude, location, and extent of radiological and chemical contamination within the facility to allow decommissioning planning. This guide amplifies guidance regarding facility characterization indicated in ASTM Standard E 1281 on Nuclear Facility Decommissioning Plans. This guide does not address the methodology necessary to release a facility or site for unconditional use. This guide specifically addresses: 1.1.1 the data quality objective for characterization as an initial step in decommissioning planning. 1.1.2 sampling methods, 1.1.3 the logic involved (statistical design) to ensure adequate characterization for decommissioning purposes; and 1.1.4 essential documentation of the characterization information. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate saf...

  9. The role of the American Society for Testing and Materials (ASTM) in providing standards to support reliability technology for nuclear power plants

    International Nuclear Information System (INIS)

    Steele, L.E.

    1978-01-01

    ASTM is an international society for managing the development of standards on characteristics and performance of materials, products, systems and services and the promotion of related knowledge. This paper provides on overview of ASTM, emphasizing its contribution to nuclear systems reliability. In so doing, the author, from his perspective as chairman of ASTM committee E 10 on ''Nuclear Applications and the Measurement of Radiation Effects and the Committee on Standards'', illustrates ASTM contributions to the understanding and control of radiation embrittlement of light-water reactor pressure vessels. Four major related taks are summarized and pertinent standards identified. These include: (1) surveillance practice (5 standards), (2) neutron dosimetry (8 standards), (3) specification for steels for nuclear service (7 standards) and (4) basic guidelines for thermal annealing to correct radiation embrittlement (1 standard). This illustration, a specific accomplishment using ASTM standards, is cited within the context of the broader nuclear-related activities of ASTM. (author)

  10. Standard guide for conducting exfoliation corrosion tests in aluminum alloys

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1992-01-01

    1.1 This guide differs from the usual ASTM standard in that it does not address a specific test. Rather, it is an introductory guide for new users of other standard exfoliation test methods, (see Terminology G 15 for definition of exfoliation). 1.2 This guide covers aspects of specimen preparation, exposure, inspection, and evaluation for conducting exfoliation tests on aluminum alloys in both laboratory accelerated environments and in natural, outdoor atmospheres. The intent is to clarify any gaps in existent test methods. 1.3 The values stated in SI units are to be regarded as the standard. The inch-pound units given in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. CCR+: Metadata Based Extended Personal Health Record Data Model Interoperable with the ASTM CCR Standard.

    Science.gov (United States)

    Park, Yu Rang; Yoon, Young Jo; Jang, Tae Hun; Seo, Hwa Jeong; Kim, Ju Han

    2014-01-01

    Extension of the standard model while retaining compliance with it is a challenging issue because there is currently no method for semantically or syntactically verifying an extended data model. A metadata-based extended model, named CCR+, was designed and implemented to achieve interoperability between standard and extended models. Furthermore, a multilayered validation method was devised to validate the standard and extended models. The American Society for Testing and Materials (ASTM) Community Care Record (CCR) standard was selected to evaluate the CCR+ model; two CCR and one CCR+ XML files were evaluated. In total, 188 metadata were extracted from the ASTM CCR standard; these metadata are semantically interconnected and registered in the metadata registry. An extended-data-model-specific validation file was generated from these metadata. This file can be used in a smartphone application (Health Avatar CCR+) as a part of a multilayered validation. The new CCR+ model was successfully evaluated via a patient-centric exchange scenario involving multiple hospitals, with the results supporting both syntactic and semantic interoperability between the standard CCR and extended, CCR+, model. A feasible method for delivering an extended model that complies with the standard model is presented herein. There is a great need to extend static standard models such as the ASTM CCR in various domains: the methods presented here represent an important reference for achieving interoperability between standard and extended models.

  12. Analysis and evaluation of the Electronic Health Record standard in China: a comparison with the American national standard ASTM E 1384.

    Science.gov (United States)

    Xu, Wei; Guan, Zhiyu; Cao, Hongxin; Zhang, Haiyan; Lu, Min; Li, Tiejun

    2011-08-01

    To analyze and evaluate the newly issued Electronic Health Record (EHR) Architecture and Data Standard of China (Chinese EHR Standard) and identify areas of improvement for future revisions. We compared the Chinese EHR Standard with the standard of the American Society for Testing and Materials Standard Practice for Content and Structure of Electronic Health Records in the United States (ASTM E 1384 Standard). The comparison comprised two steps: (1) comparing the conformance of the two standards to the international standard: Health Informatics-Requirements for an Electronic Health Record Architecture (ISO/TS 18308), and showing how the architectures of the two standards satisfy or deviate from the ISO requirements and (2) comparing the detailed data structures between the two standards. Of the 124 requirement items in ISO/TS 18308, the Chinese EHR Standard and the ASTM E 1384 Standard conformed to 77 (62.1%) and 111 (89.5%), respectively. The Chinese EHR Standard conformed to 34 of 50 Structure requirements (68.0%), 22 of 24 Process requirements (91.7%), and 21 of 50 Other requirements (42.0%). The ASTM E 1384 Standard conformed to 49 of 50 Structure requirements (98.0%), 23 of 24 Process requirements (95.8%), and 39 of 40 Other requirements (78.0%). Further development of the Chinese EHR Standard should focus on supporting privacy and security mechanism, diverse data types, more generic and extensible lower level data structures, and relational attributes for data elements. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  13. Interpreting the ASTM 'content standard for digital geospatial metadata'

    Science.gov (United States)

    Nebert, Douglas D.

    1996-01-01

    ASTM and the Federal Geographic Data Committee have developed a content standard for spatial metadata to facilitate documentation, discovery, and retrieval of digital spatial data using vendor-independent terminology. Spatial metadata elements are identifiable quality and content characteristics of a data set that can be tied to a geographic location or area. Several Office of Management and Budget Circulars and initiatives have been issued that specify improved cataloguing of and accessibility to federal data holdings. An Executive Order further requires the use of the metadata content standard to document digital spatial data sets. Collection and reporting of spatial metadata for field investigations performed for the federal government is an anticipated requirement. This paper provides an overview of the draft spatial metadata content standard and a description of how the standard could be applied to investigations collecting spatially-referenced field data.

  14. Light-water reactor pressure vessel surveillance standards

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    The master matrix standard describes a series of standard practices, guides, and methods for the prediction of neutron-induced changes in light-water reactor (LWR) pressure vessel steels throughout a pressure vessel's service life. Some of these are existing American Society for Testing and Materials (ASTM) standards, some are ASTM standards that have been modified, and some are newly proposed ASTM standards. The current (1) scope, (2) areas of application, (3) interrelationships, and (4) status and time table of development, improvement, validation, and calibration for a series of 16 ASTM standards are defined. The standard also includes a discussion of LWR pressure vessel surveillance - justification, requirements, and status of work

  15. Considerations on the ASTM standards 1789-04 and 1422-05 on the forensic examination of ink.

    Science.gov (United States)

    Neumann, Cedric; Margot, Pierre

    2010-09-01

    The ASTM standards on Writing Ink Identification (ASTM 1789-04) and on Writing Ink Comparison (ASTM 1422-05) are the most up-to-date guidelines that have been published on the forensic analysis of ink. The aim of these documents is to cover most aspects of the forensic analysis of ink evidence, from the analysis of ink samples, the comparison of the analytical profile of these samples (with the aim to differentiate them or not), through to the interpretation of the result of the examination of these samples in a forensic context. Significant evolutions in the technology available to forensic scientists, in the quality assurance requirements brought onto them, and in the understanding of frameworks to interpret forensic evidence have been made in recent years. This article reviews the two standards in the light of these evolutions and proposes some practical improvements in terms of the standardization of the analyses, the comparison of ink samples, and the interpretation of ink examination. Some of these suggestions have already been included in a DHS funded project aimed at creating a digital ink library for the United States Secret Service. © 2010 American Academy of Forensic Sciences.

  16. Standard Master Matrix for Light-Water Reactor Pressure Vessel Surveillance Standards, E706(0)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This master matrix standard describes a series of standard practices, guides, and methods for the prediction of neutron-induced changes in light-water reactor (LWR) pressure vessel (PV) and support structure steels throughout a pressure vessel's service life (Fig. 1). Some of these are existing ASTM standards, some are ASTM standards that have been modified, and some are proposed ASTM standards. General requirements of content and consistency are discussed in Section 6 . More detailed writers' and users' information, justification, and specific requirements for the nine practices, ten guides, and three methods are provided in Sections 3-5. Referenced documents are discussed in Section 2. The summary-type information that is provided in Sections 3 and 4 is essential for establishing proper understanding and communications between the writers and users of this set of matrix standards. It was extracted from the referenced documents, Section 2 and references (1-106) for use by individual writers and users. 1...

  17. Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This document provides guidance in determining absorbed-dose distributions in products, materials or substances irradiated in gamma, X-ray (bremsstrahlung) and electron beam facilities. Note 1—For irradiation of food and the radiation sterilization of health care products, other specific ISO and ISO/ASTM standards containing dose mapping requirements exist. For food irradiation, see ISO/ASTM 51204, Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing and ISO/ASTM 51431, Practice for Dosimetry in Electron and Bremsstrahlung Irradiation Facilities for Food Processing. For the radiation sterilization of health care products, see ISO 11137: 1995, Sterilization of Health Care Products Requirements for Validation and Routine Control Radiation Sterilization. In those areas covered by ISO 11137, that standard takes precedence. ISO/ASTM Practice 51608, ISO/ASTM Practice 51649, and ISO/ASTM Practice 51702 also contain dose mapping requirements. 1.2 Methods of analyzing the dose map data ar...

  18. Systematic Approach to Design Tailor Made Fuel Blends That Meets ASTM Standards

    DEFF Research Database (Denmark)

    Intikhab, S.; Kalakul, Sawitree; H., Choudhury

    2015-01-01

    point, vapor pressure, and heat content were determined using analytical instruments according to their respective American Society for Testing and Materials (ASTM) standards. Most of the properties complied well with the industry standards. However, model gasoline had a comparatively low RVP....... On the other hand, model diesel had a significantly higher cloud point and pour point than what is recommended. This deviation will have an impact on the cold flow properties of the fuels. For both fuels, different additives along with their composition have also been determined using the same computational...

  19. 76 FR 12370 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM...

    Science.gov (United States)

    2011-03-07

    ... Production Act of 1993--ASTM International Standards Notice is hereby given that, on February 4, 2011... seq. (``the Act''), ASTM International Standards (``ASTM'') has filed written notifications.... Specifically, ASTM has provided an updated list of current, ongoing ASTM standards activities originating...

  20. Development of ASTM Standard for SiC-SiC Joint Testing Final Scientific/Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Jacobsen, George [General Atomics, San Diego, CA (United States); Back, Christina [General Atomics, San Diego, CA (United States)

    2015-10-30

    As the nuclear industry moves to advanced ceramic based materials for cladding and core structural materials for a variety of advanced reactors, new standards and test methods are required for material development and licensing purposes. For example, General Atomics (GA) is actively developing silicon carbide (SiC) based composite cladding (SiC-SiC) for its Energy Multiplier Module (EM2), a high efficiency gas cooled fast reactor. Through DOE funding via the advanced reactor concept program, GA developed a new test method for the nominal joint strength of an endplug sealed to advanced ceramic tubes, Fig. 1-1, at ambient and elevated temperatures called the endplug pushout (EPPO) test. This test utilizes widely available universal mechanical testers coupled with clam shell heaters, and specimen size is relatively small, making it a viable post irradiation test method. The culmination of this effort was a draft of an ASTM test standard that will be submitted for approval to the ASTM C28 ceramic committee. Once the standard has been vetted by the ceramics test community, an industry wide standard methodology to test joined tubular ceramic components will be available for the entire nuclear materials community.

  1. 76 FR 34252 - Notice Pursuant to the National Cooperative Research and Production Act of 1993; ASTM...

    Science.gov (United States)

    2011-06-13

    ... Production Act of 1993; ASTM International Standards Notice is hereby given that, on May 11, 2011, pursuant... seq. (``the Act''), ASTM International Standards (``ASTM'') has filed written notifications.... Specifically, ASTM has provided an updated list of current, ongoing ASTM standards activities originating...

  2. Standard Guide for Recording Mechanical Test Data of Fiber-Reinforced Composite Materials in Databases

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This guide provides a common format for mechanical test data for composite materials for two purposes: (1) to establish data reporting requirements for test methods and ( 2) to provide information for the design of material property databases. This guide should be used in combination with Guide E 1309 which provides similar information to identify the composite material tested. 1.2 These guidelines are specific to mechanical tests of high-modulus fiber-reinforced composite materials. Types of tests considered in this guide include tension, compression, shear, flexure, open/filled hole, bearing, fracture toughness, and fatigue. The ASTM standards for which this guide was developed are listed in . The guidelines may also be useful for additional tests or materials. 1.3 This guide is the second part of a modular approach for which the first part is Guide E 1309. Guide E 1309 serves to identify the material, and this guide serves to describe mechanical testing procedures and variables and to record results....

  3. 77 FR 14046 - Amended Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM...

    Science.gov (United States)

    2012-03-08

    ... Research and Production Act of 1993--ASTM International Standards Notice is hereby given that, on February..., 15 U.S.C. 4301 et seq. (``the Act''), ASTM International Standards (``ASTM'') has filed written... circumstances. Specifically, ASTM has provided an updated list of current, ongoing ASTM standards activities...

  4. Impact of ASTM Standard E722 update on radiation damage metrics

    Energy Technology Data Exchange (ETDEWEB)

    DePriest, Kendall Russell [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-06-01

    The impact of recent changes to the ASTM Standard E722 is investigated. The methodological changes in the production of the displacement kerma factors for silicon has significant impact for some energy regions of the 1-MeV(Si) equivalent fluence response function. When evaluating the integral over all neutrons energies in various spectra important to the SNL electronics testing community, the change in the response results in an increase in the total 1-MeV(Si) equivalent fluence of 2 7%. Response functions have been produced and are available for users of both the NuGET and MCNP codes.

  5. 78 FR 1884 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM...

    Science.gov (United States)

    2013-01-09

    ... Production Act of 1993--ASTM International Standards Notice is hereby given that, on December 12, 2012... seq. (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between...

  6. 78 FR 35646 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM...

    Science.gov (United States)

    2013-06-13

    ... Production Act of 1993--ASTM International Standards Notice is hereby given that, on May 10, 2013, pursuant... seq. (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between...

  7. 77 FR 34069 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM...

    Science.gov (United States)

    2012-06-08

    ... Production Act of 1993--ASTM International Standards Notice is hereby given that, on May 11, 2012, pursuant... seq. (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between...

  8. 77 FR 61786 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM...

    Science.gov (United States)

    2012-10-11

    ... Production Act of 1993--ASTM International Standards Notice is hereby given that, on September 10, 2012... seq. (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between May...

  9. 78 FR 64248 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM...

    Science.gov (United States)

    2013-10-28

    ... Production Act of 1993--ASTM International Standards Notice is hereby given that, on September 16, 2013... seq. (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between May...

  10. 78 FR 14836 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM...

    Science.gov (United States)

    2013-03-07

    ... Production Act of 1993--ASTM International Standards Notice is hereby given that, on February 11, 2013... seq. (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between...

  11. Relation between the national handbook of recommended methods for water data acquisition and ASTM standards

    Science.gov (United States)

    Glysson, G. Douglas; Skinner, John V.

    1991-01-01

    In the late 1950's, intense demands for water and growing concerns about declines in the quality of water generated the need for more water-resources data. About thirty Federal agencies, hundreds of State, county and local agencies, and many private organizations had been collecting water data. However, because of differences in procedures and equipment, many of the data bases were incompatible. In 1964, as a step toward establishing more uniformity, the Bureau of the Budget (now the Office of Management and Budget, OMB) issued 'Circular A-67' which presented guidelines for collecting water data and also served as a catalyst for creating the Office of Water Data Coordination (OWDC) within the U.S. Geological Survey. This paper discusses past, present, and future aspects of the relation between methods in the National Handbook and standards published by ASTM (American Society for Testing and Materials) Committee D-19 on Water's Subcommittee D-19.07 on Sediment, Geomorphology, and Open Channel Flow. The discussion also covers historical aspects of standards - development work jointly conducted by OWDC and ASTM.

  12. HACCP: Integrating Science and Management through ASTM Standards

    Science.gov (United States)

    From a technical perspective, hazard analysis-critical control point (HACCP) evaluation may be considered a risk management tool suited to a wide range of applications. As one outcome of a symposium convened by American Society for Testing and Materials (ASTM) in August, 2005, th...

  13. 77 FR 1085 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM International

    Science.gov (United States)

    2012-01-09

    ... Production Act of 1993--ASTM International Notice is hereby given that, on December 5, 2011, pursuant to.... (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with the..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between...

  14. 75 FR 11196 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM International

    Science.gov (United States)

    2010-03-10

    ... Production Act of 1993--ASTM International Notice is hereby given that, on February 16, 2010, pursuant to.... (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with the..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between May...

  15. 75 FR 65657 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM International

    Science.gov (United States)

    2010-10-26

    ... Production Act of 1993--ASTM International Notice is hereby given that, on September 23, 2010, pursuant to.... (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with the..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between May...

  16. 76 FR 63658 - Notice Pursuant to the National Cooperative Research and Production Act of 1993; ASTM International

    Science.gov (United States)

    2011-10-13

    ... Production Act of 1993; ASTM International Notice is hereby given that, on August 31, 2011, pursuant to.... (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with the..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between May...

  17. Standard specification for tantalum and tantalum alloy plate, sheet, and strip. ASTM standard

    International Nuclear Information System (INIS)

    1998-09-01

    This specification is under the jurisdiction of ASTM Committee B-10 on Reactive and Refractory Metals and Alloys and is the direct responsibility of Subcommittee B10.03 on Niobium and Tantalum. Current edition approved May 10, 1998 and published September 1998. Originally published as B 708-82. Last previous edition was B 708-92

  18. Applying consensus standards to cask development

    International Nuclear Information System (INIS)

    Leatham, J.; Abbott, D.G.; Warrant, M.M.

    1987-01-01

    The Department of Energy's (DOE's) Office of Civilian Radioactive Waste Management is procuring cask systems for transporting commercial spent nuclear fuel and is encouraging development of innovative cask designs and materials to improve system efficiency. New designs and innovative materials require that consensus standards be established so that cask designers and regulators have criteria for determining acceptability. Recent DOE experience in certifying three spent fuel shipping casks, NUPAC-125B, TN-BRP, and TN-REG, is discussed. Certification of the NUPAC-125B was expedited because it was made of conventional American Society for Testing and Materials (ASTM) materials and complied with the American Society of Mechanical Engineers (ASME) Code and Nuclear Regulatory Commission Regulatory Guides. The TN-BRP and TN-REG cask designs are still being reviewed because baskets included in the casks are made of borated stainless steel, which has no ASTM Specification or ASME Code approval. The process of developing and approving consensus standards is discussed, including the role of ANSI and ANSI N14. Specific procedures for ASTM and ASME are described. A draft specification or standard must be prepared and then approved by the appropriate body. For new material applications to the ASME Code, an existing ASTM Specification is needed. These processes may require several years. The status of activities currently in progress to develop consensus standards for spent fuel casks is discussed, including (1) ASME NUPAC, and (2) ASTM Specifications for ductile cast iron and borated stainless steel

  19. ASTM Validates Air Pollution Test Methods

    Science.gov (United States)

    Chemical and Engineering News, 1973

    1973-01-01

    The American Society for Testing and Materials (ASTM) has validated six basic methods for measuring pollutants in ambient air as the first part of its Project Threshold. Aim of the project is to establish nationwide consistency in measuring pollutants; determining precision, accuracy and reproducibility of 35 standard measuring methods. (BL)

  20. Technical Review of Law Enforcement Standards and Guides Relative to Incident Management

    Energy Technology Data Exchange (ETDEWEB)

    Stenner, Robert D.; Salter, R.; Stanton, J. R.; Fisher, D.

    2009-03-24

    In an effort to locate potential law enforcement-related standards that support incident management, a team from the Pacific Northwest National Laboratory (PNNL) contacted representatives from the National Institute of Standards-Office of Law Enforcement Standards (NIST-OLES), National Institute of Justice (NIJ), Federal Bureau of Investigation (FBI), Secret Service, ASTM International committees that have a law enforcement focus, and a variety of individuals from local and regional law enforcement organizations. Discussions were held with various state and local law enforcement organizations. The NIJ has published several specific equipment-related law enforcement standards that were included in the review, but it appears that law enforcement program and process-type standards are developed principally by organizations that operate at the state and local level. Input is provided from state regulations and codes and from external non-government organizations (NGOs) that provide national standards. The standards that are adopted from external organizations or developed independently by state authorities are available for use by local law enforcement agencies on a voluntary basis. The extent to which they are used depends on the respective jurisdictions involved. In some instances, use of state and local disseminated standards is mandatory, but in most cases, use is voluntary. Usually, the extent to which these standards are used appears to depend on whether or not jurisdictions receive certification from a “governing” entity due to their use and compliance with the standards. In some cases, these certification-based standards are used in principal but without certification or other compliance monitoring. In general, these standards appear to be routinely used for qualification, selection for employment, and training. In these standards, the term “Peace Officer” is frequently used to refer to law enforcement personnel. This technical review of national law

  1. Validation of standard ASTM F2732 and comparison with ISO 11079 with respect to comfort temperature ratings for cold protective clothing.

    Science.gov (United States)

    Gao, Chuansi; Lin, Li-Yen; Halder, Amitava; Kuklane, Kalev; Holmér, Ingvar

    2015-01-01

    American standard ASTM F2732 estimates the lowest environmental temperature for thermal comfort for cold weather protective clothing. International standard ISO 11079 serves the same purpose but expresses cold stress in terms of required clothing insulation for a given cold climate. The objective of this study was to validate and compare the temperature ratings using human subject tests at two levels of metabolic rates (2 and 4 MET corresponding to 116.4 and 232.8 W/m(2)). Nine young and healthy male subjects participated in the cold exposure at 3.4 and -30.6 °C. The results showed that both standards predict similar temperature ratings for an intrinsic clothing insulation of 1.89 clo and for 2 MET activity. The predicted temperature rating for 2 MET activity is consistent with test subjects' thermophysiological responses, perceived thermal sensation and thermal comfort. For 4 MET activity, however, the whole body responses were on the cold side, particularly the responses of the extremities. ASTM F2732 is also limited due to its omission and simplification of three climatic variables (air velocity, radiant temperature and relative humidity) and exposure time in the cold which are of practical importance. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  2. Spectrophotometric determination of the ASTM color of diesel oil

    Energy Technology Data Exchange (ETDEWEB)

    Douglas Willian Emanuel Alves Santana; Marcelle Prates Sepulveda; Paulo Jorge Sanches Barbeira

    2007-03-15

    One of the parameters analyzed to determine the quality of diesel oil is its ASTM color. Changes in color may be indicative of problems in the production process, contamination, degradation or the oxidation of diesel. The methodology recommended for determining the color of automotive diesel oil samples is the colorimetry according to standard ASTM D1500, in which a sample is introduced into a glass cell and the color of the sample is compared with an optical filter color scale. Although it is very simple, the manual method requires good visual acuity from the operator. This procedure becomes somewhat subjective in some cases since different operators can make distinct evaluations of the same sample. In this way, this work proposes the development of a spectrophotometric analysis methodology to eliminate the subjectiveness in the determination of ASTM color of diesel oil samples by using operator-independent parameters and making quality assay more accurate and precise. Short communication. 7 refs., 2 figs., 2 tabs.

  3. Guide for dosimetry in radiation research on food and agricultural products

    International Nuclear Information System (INIS)

    2002-01-01

    This guide covers the minimum requirements for dosimetry and absorbed-dose validation needed to conduct research on the irradiation of food and agricultural products. Such research includes establishment of the quantitative relationship between the absorbed dose and the relevant effects in these products. This guide also describes the overall need for dosimetry in such research, and in reporting of the results. This guide is intended for use by research scientists in the food and agricultural communities, and not just scientists conducting irradiation research. It, therefore, includes more tutorial information than most other ASTM and ISO/ASTM dosimetry standards for radiation processing. This guide is in no way intended to limit the flexibility of the experimenter in the experimental design. However, the radiation source and experimental set up should be chosen such that the results of the experiment will be beneficial and understandable to other scientists, regulatory agencies, and the food and agricultural communities. The effects produced by ionizing radiation in biological systems depend on a large number of factors which may be physical, physiological, or chemical. Although not treated in detail in this guide, quantitative data of environmental factors that may affect the absorbed-dose response of dosimeters, such as temperature and moisture content in the food or agricultural products should be reported. The overall uncertainty in the absorbed-dose measurement and the inherent absorbed-dose range within the specimen should be taken into account in the design of an experiment. The guide covers research conducted using the following types of ionizing radiation: gamma rays, bremsstrahlung X-rays, and electron beams. This guide does not include other aspects of radiation processing research, such as planning of the experimental design. Dosimetry must be considered as an integral part of the experimental design. The guide does not include dosimetry for irradiator

  4. Measurement of susceptibility artifacts with histogram-based reference value on magnetic resonance images according to standard ASTM F2119.

    Science.gov (United States)

    Heinrich, Andreas; Teichgräber, Ulf K; Güttler, Felix V

    2015-12-01

    The standard ASTM F2119 describes a test method for measuring the size of a susceptibility artifact based on the example of a passive implant. A pixel in an image is considered to be a part of an image artifact if the intensity is changed by at least 30% in the presence of a test object, compared to a reference image in which the test object is absent (reference value). The aim of this paper is to simplify and accelerate the test method using a histogram-based reference value. Four test objects were scanned parallel and perpendicular to the main magnetic field, and the largest susceptibility artifacts were measured using two methods of reference value determination (reference image-based and histogram-based reference value). The results between both methods were compared using the Mann-Whitney U-test. The difference between both reference values was 42.35 ± 23.66. The difference of artifact size was 0.64 ± 0.69 mm. The artifact sizes of both methods did not show significant differences; the p-value of the Mann-Whitney U-test was between 0.710 and 0.521. A standard-conform method for a rapid, objective, and reproducible evaluation of susceptibility artifacts could be implemented. The result of the histogram-based method does not significantly differ from the ASTM-conform method.

  5. Standardized physics-dosimetry for US pressure vessel cavity surveillance programs

    International Nuclear Information System (INIS)

    Ruddy, F.H.; McElroy, W.N.; Lippincott, E.P.

    1984-01-01

    This paper summarizes the applications of ASTM standard methods, guides and practices to define the selection and deployment of recommended dosimetry sets, the selection of dosimetry capsules and thermal neutron shields, the placement of dosimetry, the methods of measurement of dosimetry sensor reaction products, data analysis procedures, and uncertainty evaluation procedures. It also describes the validation of these standards both by in-reactor testing of advanced PV cavity surveillance physics-dosimetry and by data development. The use of these standards to guide selection and development of advanced dosimetry sets for commercial reactors is also summarized. (Auth.)

  6. PROPOSED ASTM METHOD FOR THE DETERMINATION OF ASBESTOS IN AIR BY TEM AND INFORMATION ON INTERFERING FIBERS

    Science.gov (United States)

    The draft of the ASTM Test Method for air entitled: "Airborne Asbestos Concentration in Ambient and Indoor Atmospheres as Determined by Transmission Electron Microscopy Direct Transfer (TEM)" (ASTM Z7077Z) is an adaptation of the International Standard, ISO 10312. It is currently...

  7. ASTM and ASME-BPE Standards--Complying with the Needs of the Pharmaceutical Industry.

    Science.gov (United States)

    Huitt, William M

    2011-01-01

    Designing and building a pharmaceutical facility requires the owner, engineer of record, and constructor to be knowledgeable with regard to the industry codes and standards that apply to this effort. Up until 1997 there were no industry standards directed at the needs and requirements of the pharmaceutical industry. Prior to that time it was a patchwork effort at resourcing and adopting nonpharmaceutical-related codes and standards and then modifying them in order to meet the more stringent requirements of the Food and Drug Administration (FDA). In 1997 the American Society of Mechanical Engineers (ASME) published the first Bioprocessing Equipment (BPE) Standard. Through harmonization efforts this relatively new standard has brought together, scrutinized, and refined industry accepted methodologies together with FDA compliance requirements, and has established an American National Standard that provides a comprehensive set of standards that are integral to the pharmaceutical industry. This article describes various American National Standards, including those developed and published by the American Society for Testing and Materials (ASTM), and how they apply to the pharmaceutical industry. It goes on to discuss the harmonization effort that takes place between the various standards developers in an attempt to prevent conflicts and omissions between the many standards. Also included are examples of tables and figures taken from the ASME-BPE Standard. These examples provide the reader with insight to the relevant content of the ASME-BPE Standard. Designing and building a pharmaceutical facility requires the owner, engineer of record, and constructor to be knowledgeable with regard to the industry codes and standards that apply to this effort. Up until 1997 there were no industry standards directed at the needs and requirements of the pharmaceutical industry. Prior to that time it was a patchwork effort at resourcing and adopting nonpharmaceutical-related codes and

  8. Silicon Damage Response Function Derivation and Verification: Assessment of Impact on ASTM Standard E722

    Energy Technology Data Exchange (ETDEWEB)

    Depriest, Kendall [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-06-01

    Unsuccessful attempts by members of the radiation effects community to independently derive the Norgett-Robinson-Torrens (NRT) damage energy factors for silicon in ASTM standard E722-14 led to an investigation of the software coding and data that produced those damage energy factors. The ad hoc collaboration to discover the reason for lack of agreement revealed a coding error and resulted in a report documenting the methodology to produce the response function for the standard. The recommended changes in the NRT damage energy factors for silicon are shown to have significant impact for a narrow energy region of the 1-MeV(Si) equivalent fluence response function. However, when evaluating integral metrics over all neutrons energies in various spectra important to the SNL electronics testing community, the change in the response results in a small decrease in the total 1- MeV(Si) equivalent fluence of ~0.6% compared to the E722-14 response. Response functions based on the newly recommended NRT damage energy factors have been produced and are available for users of both the NuGET and MCNP codes.

  9. ASTM Committee D-7 : Wood : promoting safety and standardization for 100 years

    Science.gov (United States)

    David W. Green; Robert L. Ethington

    2004-01-01

    In October 2004, Committee D-7 on Wood of the American Society for Testing and Materials (ASTM) is celebrating 100 years of contributions to the safe and efficient use of wood as a building material. Born during a period of rapid social, economic, and technological change, the Committee faced controversial issues and the challenge of a changing forest resource. This...

  10. Standard test method for compressive strength of grouts for preplaced-aggregate concrete in the laboratory. ASTM standard

    International Nuclear Information System (INIS)

    1998-10-01

    DoD adopted. This test method is under the jurisdiction of ASTM Committee C-9 on Concrete and Concrete Aggregates and is the direct responsibility of Subcommittee C09.41 on Concrete for Radiation Shielding. Current edition approved Feb. 10, 1986 and published October 1998. Originally published as C 942-81. Last previous edition was C 942-86(1991)

  11. Standard test method for static leaching of monolithic waste forms for disposal of radioactive waste. ASTM standard

    International Nuclear Information System (INIS)

    1998-10-01

    This test method is under the jurisdiction of ASTM Committee C-26 on Nuclear Fuel Cycles and is the direct responsibility of Subcommittee C26.07 on Waste Materials. The current edition was approved July 10, 1998, and published in October 1998. It was originally published as C 1220-92. The last previous edition was C 1220-92

  12. Modification of ASTM Standard E1681 on Environmental Cracking to Include Bolt-Load Specimen Testing

    National Research Council Canada - National Science Library

    Underwood, Jean D. M

    1997-01-01

    Benet Laboratories experience with environmental cracking of cannon components has been combined with the technical expertise of various participants at ASTM technical meetings and symposia to develop...

  13. Empirical ranking of a wide range of WC-Co grades in terms of their abrasion resistance measured by the ASTM standard B 611-85 test

    CSIR Research Space (South Africa)

    O'Quigley, DGF

    1997-01-01

    Full Text Available This paper reports the results of a comprehensive investigation into the abrasion resistance of WC-Co alloys, as measured by the ASTM Standard B 611-85 test. The alloys ranged from 3 to 50 wt% and from 0.6 to 5 mu-m average grain size. Careful...

  14. Evaluation of ozonated water using ASTM E1174 for standardized testing of handwash formulations for healthcare personnel.

    Science.gov (United States)

    Nakamura, K; Saito, K; Kashiwazaki, J; Aoyagi, T; Arai, K; Hara, Y; Kobari, S; Mori, H; Ohashi, K; Takano, Y; Kaku, M; Kanemitsu, K

    2018-02-13

    Removal of bacteria by handwashing with ozonated water was evaluated using the ASTM E1174 standard test method. Thirty healthy volunteers were assigned randomly to three groups: ozonated water, antimicrobial soap and water, and non-antimicrobial soap and water. A 3 log 10  cfu reduction was achieved by washing hands with ozonated water or antimicrobial soap and water. However, ozonated water was not significantly superior to non-antimicrobial soap and water. Ozonated water may remove bacteria from the hands to at least a similar extent as that by non-antimicrobial soap and water in the absence of visible dirt or body fluid contamination. Copyright © 2018 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  15. Current and future neutron radiography standards

    International Nuclear Information System (INIS)

    Brenizer, J.S.

    1999-01-01

    Only two organizations are actively producing standards which are used in neutron radiology (NR): the American Society of Testing and Materials (ASTM) and the International Organization for Standardization (ISO). Six ASTM standards exist that address the neutron radiography method. Two of the ASTM standards have been extensively used world-wide. ISO has a working group which is developing three standards that also address the neutron radiography method. Two of these are currently making their way through the ISO approval system. No ASTM or ISO standards exist for the neutron radioscopic method. Future ASTM standards will address the neutron radioscopic method and neutron radiologic system characterization. It is expected that similar efforts will be undertaken in ISO. Given the relatively small community providing neutron radiologic services, international cooperation and the need for ISO standards will most likely continue to grow.(author)

  16. International cooperative effort to establish ASTM [American Society for Testing and Materials] standards for the measurement of radiation dose for food processing

    International Nuclear Information System (INIS)

    Farrar, H. IV.

    1987-01-01

    A task group has been formed within the American Society for Testing and Materials (ASTM) specifically to develop standards for measuring radiation dose for food processing. The task group, which has 78 members, including 16 from Europe, consists of a broad cross section of food industry, government, regulatory, manufacturing, and university interests. The group is working on seven standards; three specifically for food irradiation applications, and four for using specific dosimeter types for all radiation applications, including food processing. Together, this set of standards will specify acceptable methods of accomplishing the required irradiation treatment of food and other products, and will be available for adoption by regulatory agencies in food irradiation protocols. 1 tab

  17. Twenty new ISO standards on dosimetry for radiation processing

    International Nuclear Information System (INIS)

    Farrar IV, H.

    2000-01-01

    Twenty standards on essentially all aspects of dosimetry for radiation processing were published as new ISO standards in December 1998. The standards are based on 20 standard practices and guides developed over the past 14 years by Subcommittee E10.01 of the American Society for Testing and Materials (ASTM). The transformation to ISO standards using the 'fast track' process under ISO Technical Committee 85 (ISO/TC85) commenced in 1995 and resulted in some overlap of technical information between three of the new standards and the existing ISO Standard 11137 Sterilization of health care products - Requirements for validation and routine control - Radiation sterilization. Although the technical information in these four standards was consistent, compromise wording in the scopes of the three new ISO standards to establish precedence for use were adopted. Two of the new ISO standards are specifically for food irradiation applications, but the majority apply to all forms of gamma, X-ray, and electron beam radiation processing, including dosimetry for sterilization of health care products and the radiation processing of fruit, vegetables, meats, spices, processed foods, plastics, inks, medical wastes, and paper. Most of the standards provide exact procedures for using individual dosimetry systems or for characterizing various types of irradiation facilities, but one covers the selection and calibration of dosimetry systems, and another covers the treatment of uncertainties using the new ISO Type A and Type B evaluations. Unfortunately, nine of the 20 standards just adopted by the ISO are not the most recent versions of these standards and are therefore already out of date. To help solve this problem, efforts are being made to develop procedures to coordinate the ASTM and ISO development and revision processes for these and future ASTM-originating dosimetry standards. In the meantime, an additional four dosimetry standards have recently been published by the ASTM but have

  18. Guide for use of radiation-sensitive indicators. 2. ed.

    International Nuclear Information System (INIS)

    2002-01-01

    This guide covers the use of radiation-sensitive indicators in radiation processing. These indicators may be labels, papers, inks or packaging materials which undergo a color change or become colored when exposed to ionizing radiation. The purpose of these indicators is to determine visually whether or not a product has been irradiated, rather than to measure different dose levels. Such materials are not dosimeters and should not be used as a substitute for proper dosimetry. Information about dosimetry systems for ionizing radiation is provided in other ASTM and ISO/ASTM documents (see ISO/ASTM Guide 51261

  19. ASTM lights the way for tissue engineered medical products standards: jump start for combination medical products that restore biological function of human tissues.

    Science.gov (United States)

    Picciolo, G L; Stocum, D L

    2001-01-01

    Everybody hopes for better health and restoration of impaired bodily function, and now that hope is illuminated by the promise of powerful biological tools that make human cells grow and replace human tissue. ASTM Committee F04 on Medical and Surgical Materials and Devices is taking the lead by defining some of those tools as standards that can be used for the development, production, testing, and regulatory approval of medical products.

  20. Development and testing of standardized procedures and reference data for LWR surveillance

    International Nuclear Information System (INIS)

    McElroy, W.N.

    1979-02-01

    The resources and talents of many national and international organizations and laboratories, both governmental and industrial, are being used to establish analysis methods for predicting the embrittlement condition of light water reactor (LWR) primary systems. The exact interrelationships and responsibilities between those developing, understanding, combining, and applying state-of-the-art technology in dosimetry, metallurgy, and fracture mechanics for reactor systems analysis are being carefully reviewed and studied. This has resulted in a more comprehensive definition of the scope of new and updated ASTM standards required for the analysis and interpretation of LWR pressure vessel surveillance results. Fifteen new and updated ASTM standards have now been identified, together with a restructuring of the main interfaces between the individual standard practices, guides, and methods. The paper briefly discusses these standards and the initial results of multi-laboratory research work involved in their validation and calibration

  1. Standard specification for cobalt-chromium-nickel-molybdenum-tungsten alloy (UNS R31233) plate, sheet and strip. ASTM standard

    International Nuclear Information System (INIS)

    1998-09-01

    This specification is under the jurisdiction of ASTM Committee B-2 on Nonferrous Metals and Alloys and is the direct responsibility of Subcommittee B02.07 on Refined Nickel and Cobalt, and Alloys Containing Nickel or Cobalt or Both as Principal Constituents. Current edition approved Apr. 10, 1998 and published September 1998. Originally published as B 818-91. Last previous edition was B 818-93

  2. Overview (this manuscript is an overview of an ASTM ...

    Science.gov (United States)

    The Symposium on Developing Consensus Standards for Measuring Chemical Emissions from Spray Polyurethane Foam (SPF) Insulation was held on April 30th and May 1, 2015. Sponsored by ASTM Committee D22 on Air Quality, the symposium was held in Anaheim, CA, in conjunction with the standards development meetings of the Committee. ASTM D22.05 is developing tools to answer fundamental questions: what is emitted from SPF, how long do the emissions persist, how does ventilation impact concentrations and potential exposures? How can we model these processes to address the multiplicity of products, applications, and environmental conditions that may impact exposure to emissions over the life cycle of the material? These are complex and interrelated questions that have challenged the indoor environments research community for many years. Objectives of Symposium: Standardized methods are needed to assess the potential impacts of SPF insulation products on indoor air quality, establish re-entry times for trade workers or re-occupancy times for building occupants after product installation and to evaluate post-occupancy ventilation. The objective of the symposium was to provide a forum for the exchange of ideas from SPF manufacturers, regulatory agencies, indoor air quality professionals, testing labs, air quality consultants, instrument vendors and other stakeholders. Following the presentations on the current status of measuring emissions from SPF insulation, participants di

  3. An evaluation of efforts by nuclear power plants to use ASTM D3803-89

    International Nuclear Information System (INIS)

    Freeman, W.P.

    1995-01-01

    The number of nuclear power plants are now using ASTM D3803-89, open-quotes Standard Test Method for Nuclear-Grade Activated Carbonclose quotes for routine surveillance testing of adsorbents. In order to judge the impact of this change, we have gathered radioiodine removal test results from our data base on a system-by-system basis (i.e. control room, technical support center, and spent fuel pool) and compared test results obtained for the same kind of systems using the new and older test methods. Included in this comparison are systems with and without humidity control. Results are discussed from the standpoint of what to expect if a change to testing using ASTM D3803-89 is contemplated, especially regarding test results in light existing acceptance criteria. Additionally, the results are discussed from the standpoint of the sensitivity of the ASTM test method to detect when the performance of the carbon in air cleaning systems has been compromised (compared to the older methods). Finally, we offer some suggestions for how other plants might upgrade their carbon testing to incorporate testing to ASTM D3803-89

  4. An evaluation of efforts by nuclear power plants to use ASTM D3803-89

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, W.P.

    1995-02-01

    The number of nuclear power plants are now using ASTM D3803-89, {open_quotes}Standard Test Method for Nuclear-Grade Activated Carbon{close_quotes} for routine surveillance testing of adsorbents. In order to judge the impact of this change, we have gathered radioiodine removal test results from our data base on a system-by-system basis (i.e. control room, technical support center, and spent fuel pool) and compared test results obtained for the same kind of systems using the new and older test methods. Included in this comparison are systems with and without humidity control. Results are discussed from the standpoint of what to expect if a change to testing using ASTM D3803-89 is contemplated, especially regarding test results in light existing acceptance criteria. Additionally, the results are discussed from the standpoint of the sensitivity of the ASTM test method to detect when the performance of the carbon in air cleaning systems has been compromised (compared to the older methods). Finally, we offer some suggestions for how other plants might upgrade their carbon testing to incorporate testing to ASTM D3803-89.

  5. An Evaluation of a Proposed Revision of the ASTM D 1990 Grouping Procedure

    Science.gov (United States)

    Steve P Verrill; James W. Evans; David E. Kretschmann; Cherilyn A. Hatfield

    2013-01-01

    Lum, Taylor, and Zidek have proposed a revised procedure for wood species grouping in ASTM standard D 1990. We applaud the authors’ recognition of the importance of considering a strength distribution’s variability as well as its fifth percentile. However, we have concerns about their proposed method of incorporating this information into a standard. We detail these...

  6. Standard guide for computed radiography

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This guide provides general tutorial information regarding the fundamental and physical principles of computed radiography (CR), definitions and terminology required to understand the basic CR process. An introduction to some of the limitations that are typically encountered during the establishment of techniques and basic image processing methods are also provided. This guide does not provide specific techniques or acceptance criteria for specific end-user inspection applications. Information presented within this guide may be useful in conjunction with those standards of 1.2. 1.2 CR techniques for general inspection applications may be found in Practice E2033. Technical qualification attributes for CR systems may be found in Practice E2445. Criteria for classification of CR system technical performance levels may be found in Practice E2446. Reference Images Standards E2422, E2660, and E2669 contain digital reference acceptance illustrations. 1.3 The values stated in SI units are to be regarded as the st...

  7. Standard Guide for Conducting Supplemental Surveillance Tests for Nuclear Power Reactor Vessels, E 706 (IH)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This guide discusses test procedures that can be used in conjunction with, but not as alternatives to, those required by Practices E185 and E2215 for the surveillance of nuclear reactor vessels. The supplemental mechanical property tests outlined permit the acquisition of additional information on radiation-induced changes in fracture toughness, notch ductility, and yield strength properties of the reactor vessel steels. 1.2 This guide provides recommendations for the preparation of test specimens for irradiation, and identifies special precautions and requirements for reactor surveillance operations and postirradiation test planning. Guidance on data reduction and computational procedures is also given. Reference is made to other ASTM test methods for the physical conduct of specimen tests and for raw data acquisition.

  8. Comparison of ASTM D613 and ASTM D6890

    Science.gov (United States)

    2016-04-01

    cetane values outside of the routine range of traditional CN testing by ASTM D613, this is an important advantage in fuel blending and disposition...Number testing. Particular emphasis was placed on evaluating fuels, and blends thereof, having cetane values outside of the normal range of the...interest covers both petroleum-based and synthetic-based, as well as blends thereof in order to improve the confidence in using DCN as a replacement

  9. Standard guide for digital detector array radiology

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This standard is a user guide, which is intended to serve as a tutorial for selection and use of various digital detector array systems nominally composed of the detector array and an imaging system to perform digital radiography. This guide also serves as an in-detail reference for the following standards: Practices E2597, , and E2737. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. Comparing the Methodologies in ASTM G198: Is There an Easy Way Out?

    Science.gov (United States)

    Samuel L. Zelinka

    2013-01-01

    ASTM(1) G198, Standard test method for determining the relative corrosion performance of driven fasteners in contact with treated wood, was accepted by consensus and published in 2011. The method has two different exposure conditions for determining fastener corrosion performance in treated wood. The first method places the wood and embedded...

  11. Standardized physics-dosimetry for US pressure vessel cavity surveillance programs

    International Nuclear Information System (INIS)

    Ruddy, F.H.; McElroy, W.N.; Lippincott, E.P.

    1984-01-01

    Standardized Physics-Dosimetry procedures and data are being developed and tested for monitoring the neutron doses accumulated by reactor pressure vessels (PV) and their support structures. These procedures and data are governed by a set of 21 ASTM standard practices, guides, and methods for the prediction of neutron-induced changes in light water reactor (LWR) PVs and support structure steels throughout the service life of the PV. This paper summarizes the applications of these standards to define the selection and deployment of recommended dosimetry sets, the selection of dosimetry capsules and thermal neutron shields, the placement of dosimetry, the methods of measurement of dosimetry sensor reaction products, data analysis procedures, and uncertainty evaluation procedures. It also describes the validation of these standards both by in-reactor testing of advanced PV cavity surveillance physics-dosimetry and by data development. The use of these standards to guide selection and deployment of advanced dosimetry sets for commercial reactors is also summarized

  12. Comparing the Methodologies in ASTM G198 Using Combined Hygrothermal-Corrosion Modeling

    Science.gov (United States)

    Samuel L. Zelinka

    2013-01-01

    ASTM G198, “Standard test method for determining the relative corrosion performance of driven fasteners in contact with treated wood,” was accepted by consensus and published in 2011. The method has two different exposure conditions for determining fastener corrosion performance in treated wood. The first method places the wood and embedded fasteners in a...

  13. 1991 annual book of ASTM standards

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    This book contains nuclear technology standards also features test methods and practices for solar and geotechnical energy. In the nuclear category, the primary emphasis of this volume is on analysis, dosimetry, and radiation effects in materials. Over eighty standards primarily test methods and practices are featured in this category

  14. Results of ASTM round robin testing for mode 1 interlaminar fracture toughness of composite materials

    Science.gov (United States)

    Obrien, T. Kevin; Martin, Roderick H.

    1992-01-01

    The results are summarized of several interlaboratory 'round robin' test programs for measuring the mode 1 interlaminar fracture toughness of advanced fiber reinforced composite materials. Double Cantilever Beam (DCB) tests were conducted by participants in ASTM committee D30 on High Modulus Fibers and their Composites and by representatives of the European Group on Fracture (EGF) and the Japanese Industrial Standards Group (JIS). DCB tests were performed on three AS4 carbon fiber reinforced composite materials: AS4/3501-6 with a brittle epoxy matrix; AS4/BP907 with a tough epoxy matrix; and AS4/PEEK with a tough thermoplastic matrix. Difficulties encountered in manufacturing panels, as well as conducting the tests are discussed. Critical issues that developed during the course of the testing are highlighted. Results of the round robin testing used to determine the precision of the ASTM DCB test standard are summarized.

  15. Standard practice for application of thermoluminescence-dosimetry (TLD) systems for determining absorbed dose in radiation-hardness testing of electronic devices. ASTM standard

    International Nuclear Information System (INIS)

    1998-05-01

    This practice is under the jurisdiction of ASTM Committee E-10 on Nuclear Technology and Applications and is the direct responsibility of Subcommittee E10.07 on Radiation Dosimetry for Radiation Effects on Materials and Devices. Current edition approved Jun. 10, 1997. Published May 1998. Originally published as E 668-78. Last previous edition E 668-93

  16. Disinfectant wipes are appropriate to control microbial bioburden from surfaces: use of a new ASTM standard test protocol to demonstrate efficacy.

    Science.gov (United States)

    Sattar, S A; Bradley, C; Kibbee, R; Wesgate, R; Wilkinson, M A C; Sharpe, T; Maillard, J-Y

    2015-12-01

    The use of disinfectant pre-soaked wipes (DPW) to decontaminate high-touch environmental surfaces (HTES) by wiping is becoming increasingly widespread in the healthcare environment. However, DPW are rarely tested using conditions simulating their field use, and the label claims of environmental surface disinfectants seldom include wiping action. To evaluate the new E2967-15 standard test specific to wipes, particularly their ability to decontaminate surfaces and to transfer acquired contamination to clean surfaces. ASTM Standard E2967-15 was used by three independent laboratories to test the efficacy of five types of commercially available wipe products. All data generated were pulled together, and reproducibility and repeatability of the standard were measured. All the commercial DPW tested achieved a >4log10 (>99.99%) reduction in colony-forming units (CFU) of Staphylococcus aureus and Acinetobacter baumanii with 10s of wiping, but only one DPW containing 0.5% accelerated H2O2 prevented the transfer of bacteria to another surface. This newly introduced standard method represents a significant advance in assessing DPW for microbial decontamination of HTES, and should greatly assist research and development, and in making more relevant and reliable claims on marketed DPW. Copyright © 2015. Published by Elsevier Ltd.

  17. Use of Bayesian Methods to Analyze and Visualize Content Uniformity Capability Versus United States Pharmacopeia and ASTM Standards.

    Science.gov (United States)

    Hofer, Jeffrey D; Rauk, Adam P

    2017-02-01

    The purpose of this work was to develop a straightforward and robust approach to analyze and summarize the ability of content uniformity data to meet different criteria. A robust Bayesian statistical analysis methodology is presented which provides a concise and easily interpretable visual summary of the content uniformity analysis results. The visualization displays individual batch analysis results and shows whether there is high confidence that different content uniformity criteria could be met a high percentage of the time in the future. The 3 tests assessed are as follows: (a) United States Pharmacopeia Uniformity of Dosage Units , (b) a specific ASTM E2810 Sampling Plan 1 criterion to potentially be used for routine release testing, and (c) another specific ASTM E2810 Sampling Plan 2 criterion to potentially be used for process validation. The approach shown here could readily be used to create similar result summaries for other potential criteria. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  18. National standards for the nuclear industry

    International Nuclear Information System (INIS)

    Laing, W.R.; Corbin, L.T.

    1981-01-01

    Standards needs for the nuclear industry are being met by a number of voluntary organizations, such as ANS, ASTM, AWS, ASME, and IEEE. The American National Standards Institute (ANSI) coordinates these activities and approves completed standards as American National Standards. ASTM has two all-nuclear committees, E-10 and C-26. A C-26 subcommittee, Test Methods, has been active in writing analytical chemistry standards for twelve years. Thirteen have been approved as ANSI standards and others are ready for ballot. Work is continuing in all areas of the nuclear fuel cycle

  19. Stress corrosion (Astm G30-90 standard) in 08x18H10T stainless steel of nuclear fuel storage pool in WWER reactors

    International Nuclear Information System (INIS)

    Herrera, V.; Zamora R, L.

    1997-01-01

    At the water storage of the irradiated nuclear fuel has been an important factor in its management. The actual pools have its walls covered with inoxidable steel and heat exchangers to dissipate the residual heat from fuel. It is essential to control the water purity to eliminate those conditions which aid to the corrosion process in fuel and at related components. The steel used in this research was obtained from an austenitic inoxidizable steel standardized with titanium 08x18H10T (Type 321) similar to one of the two steel coatings used to cover walls and the pools floor. the test consisted in the specimen deformation through an U ply according to the Astm G30-90 standard. The exposition of the deformed specimen it was realized in simulated conditions to the chemical regime used in pools. (Author)

  20. Standard guide for sampling radioactive tank waste

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This guide addresses techniques used to obtain grab samples from tanks containing high-level radioactive waste created during the reprocessing of spent nuclear fuels. Guidance on selecting appropriate sampling devices for waste covered by the Resource Conservation and Recovery Act (RCRA) is also provided by the United States Environmental Protection Agency (EPA) (1). Vapor sampling of the head-space is not included in this guide because it does not significantly affect slurry retrieval, pipeline transport, plugging, or mixing. 1.2 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  1. ASTM and VAMAS activities in titanium matrix composites test methods development

    Science.gov (United States)

    Johnson, W. S.; Harmon, D. M.; Bartolotta, P. A.; Russ, S. M.

    1994-01-01

    Titanium matrix composites (TMC's) are being considered for a number of aerospace applications ranging from high performance engine components to airframe structures in areas that require high stiffness to weight ratios at temperatures up to 400 C. TMC's exhibit unique mechanical behavior due to fiber-matrix interface failures, matrix cracks bridged by fibers, thermo-viscoplastic behavior of the matrix at elevated temperatures, and the development of significant thermal residual stresses in the composite due to fabrication. Standard testing methodology must be developed to reflect the uniqueness of this type of material systems. The purpose of this paper is to review the current activities in ASTM and Versailles Project on Advanced Materials and Standards (VAMAS) that are directed toward the development of standard test methodology for titanium matrix composites.

  2. Nonreactor nuclear facilities: standards and criteria guide

    International Nuclear Information System (INIS)

    Brynda, W.J.; Junker, L.; Karol, R.C.; Lobner, P.R.; Goldman, L.A.

    1981-09-01

    This guide is a source document that identifies standards, codes, and guides that address the nuclear safety considerations pertinent to nuclear facilities as defined in DOE Order 5480.1, Chapter V, Safety of Nuclear Facilities. The guidance and criteria provided are directed toward areas of safety usually addressed in a Safety Analysis Report. The areas of safety include, but are not limited to, siting, principal design criteria and safety system design guidelines, radiation protection, accident analysis, and quality assurance. The guide is divided into two sections: general guidelines and appendices. Those guidelines that are broadly applicable to most nuclear facilities are presented in the general guidelines. These general guidelines may have limited applicability to subsurface facilities such as waste repositories. Guidelines specific to the various types or categories of nuclear facilities are presented in the appendices. These facility-specific appendices provide guidelines and identify standards and criteria that should be considered in addition to, or in lieu of, the general guidelines

  3. Nonreactor nuclear facilities: Standards and criteria guide

    International Nuclear Information System (INIS)

    Brynda, W.J.; Scarlett, C.H.; Tanguay, G.E.; Lobner, P.R.

    1986-09-01

    This guide is a source document that identifies standards, codes, and guides that address the nuclear safety considerations pertinent to nuclear facilities as defined in DOE 5480.1A, Chapter V, ''Safety of Nuclear Facilities.'' The guidance and criteria provided is directed toward areas of safety usually addressed in a Safety Analysis Report. The areas of safety include, but are not limited to, siting, principal design criteria and safety system design guidelines, radiation protection, accident analysis, conduct of operations, and quality assurance. The guide is divided into two sections: general guidelines and appendices. Those guidelines that are broadly applicable to most nuclear facilities are presented in the general guidelines. Guidelines specific to the various types or categories of nuclear facilities are presented in the appendices. These facility-specific appendices provide guidelines and identify standards and criteria that should be considered in addition to, or in lieu of, the general guidelines. 25 figs., 62 tabs

  4. 24 CFR Appendix A to Part 200 - Standards Incorporated by Reference in the Minimum Property Standards for Housing (HUD Handbook...

    Science.gov (United States)

    2010-04-01

    ... 19103, Telephone (215) 299-5400. ASTM C 12-91 Standard Practice for Installing Vitrified Clay Pipe Lines... C 216-91c Standard Specification for Facing Brick (Solid Masonry Units Made from Clay or Shale) ASTM.../78 77a Cast Iron Sanitary Drainage System with Hubless Pipe and Fittings—3/28/80 78 Polyethylene (PE...

  5. Vacuum decay container/closure integrity testing technology. Part 1. ASTM F2338-09 precision and bias studies.

    Science.gov (United States)

    Wolf, Heinz; Stauffer, Tony; Chen, Shu-Chen Y; Lee, Yoojin; Forster, Ronald; Ludzinski, Miron; Kamat, Madhav; Godorov, Phillip; Guazzo, Dana Morton

    2009-01-01

    ASTM F2338-09 Standard Test Method for Nondestructive Detection of Leaks in Packages by Vacuum Decay Method is applicable for leak-testing rigid and semi-rigid non-lidded trays; trays or cups sealed with porous barrier lidding materials; rigid, nonporous packages; and flexible, nonporous packages. Part 1 of this series describes the precision and bias studies performed in 2008 to expand this method's scope to include rigid, nonporous packages completely or partially filled with liquid. Round robin tests using three VeriPac 325/LV vacuum decay leak testers (Packaging Technologies & Inspection, LLC, Tuckahoe, NY) were performed at three test sites. Test packages were 1-mL glass syringes. Positive controls had laser-drilled holes in the barrel ranging from about 5 to 15 microm in nominal diameter. Two different leak tests methods were performed at each site: a "gas leak test" performed at 250 mbar (absolute) and a "liquid leak test" performed at about 1 mbar (absolute). The gas leak test was used to test empty, air-filled syringes. All defects with holes > or = 5.0 microm and all no-defect controls were correctly identified. The only false negative result was attributed to a single syringe with a ASTM F2338-09 test method and the precision and bias study report are available by contacting ASTM International in West Conshohocken, PA, USA (www.astm.org).

  6. Characterization of ASTM round-robin tungsten-powder samples

    International Nuclear Information System (INIS)

    Slettevold, C.A.; Biermann, A.H.

    1975-01-01

    The Lawrence Livermore Laboratory Particle Characterization Laboratory Group has participated in an industry-wide round-robin investigation on characterization of tungsten powder. sponsored by the ASTM Subcommittee on Refractory-Metal Powders (B-09.3). The analyses performed at the suggestion of the ASTM subcommittee included measurements of tap density, apparent density, true density, average particle size, and surface area. Determinations of particle-weight and size distributions were also performed and particle inspection conducted by microscopy. This report describes the equipment and procedures used and summarizes the results of these analyses. (9 tables, 17 fig) (U.S.)

  7. 77 FR 37587 - Updating OSHA Standards Based on National Consensus Standards; Head Protection

    Science.gov (United States)

    2012-06-22

    ... Z89.1-2003 as Appendix E, to the main text. Adds ``ASTM E1164-02 Colorimetry--Standard Practice for... National complete citations for standards on Standards Referred to in This colorimetry, headforms, and...

  8. 77 FR 37617 - Updating OSHA Standards Based on National Consensus Standards; Head Protection

    Science.gov (United States)

    2012-06-22

    ... Z89.1-2003 as Appendix E, to the main text. Adds ``ASTM E1164-02 Colorimetry--Standard Practice for... National complete citations for standards on Standards Referred to in This colorimetry, headforms, and...

  9. 75 FR 30440 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM International

    Science.gov (United States)

    2010-06-01

    ... Production Act of 1993--ASTM International Notice is hereby given that, on May 6, 2010, pursuant to Section 6... Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with the Attorney... recovery of antitrust plaintiffs to actual damages under specified circumstances. Specifically, ASTM has...

  10. Dosimetry-adjusted reactor physics parameters for pressure vessel neutron exposure assessment

    International Nuclear Information System (INIS)

    McElroy, W.N.; Kellogg, L.S.

    1988-01-01

    The ASTM E706 master matrix standard describes a series of 20 American Society for Testing and Materials (ASTM) standard practices, guides, and methods for use in the prediction of neutron-induced changes in light water reactor (LWR) pressure vessel (PV) and support structure steels throughout a PV's service life. Some of these are existing ASTM standards, some are ASTM standards that have been modified, and some are new ASTM standards. These standards are periodically revised to assume their applicability during the 40-yr (32 effective full-power years) design license period for a nuclear power plant. They are now under review by two new ASTM plant life extension task groups: E10.05.11 on physics dosimetry and E10.02.11 on metallurgy. A brief review on the current application of these standards and a discussion of the status of work to verify the accuracy of derived physics-dosimetry parameter values is presented in this paper

  11. Corrosion resistance and microstructure of alloy 625 weld overlay on ASTM A516 grade 70

    Energy Technology Data Exchange (ETDEWEB)

    Moradi, Mohammad J. [Amirkabir Univ. of Technology, Tehran (Iran, Islamic Republic of). Petroleum Engineering Dept.; Ketabchi, Mostafa [Amirkabir Univ. of Technology, Tehran (Iran, Islamic Republic of). Mining and Metallurgical Engineering Dept.

    2016-02-01

    Nickel-based alloys are a crucial class of materials because of their excellent corrosion resistance. In the present study, single layer and two layers alloy 625 weld overlays were deposited by GTAW process on A516 grade 70 carbon steel. The dilution in terms of Fe, Ni, Mo and Nb content was calculated in 30 points of weld overlay. Microstructure observations showed that alloy 625 had austenitic structure with two types of Laves and NbC secondary phases. The uniform and pitting corrosion resistance of alloy 625 weld overlay as casted and as forged were evaluated in accordance with ASTM G48-2011 standard at different temperatures to determine the weight loss and critical pitting temperature. For achieving a better comparison, samples from alloy 625 as casted and as forged were tested under the same conditions. The results point out that single layer alloy 625 weld overlay is not suitable for chloride containing environments, two layers alloy 625 weld overlay and alloy 625 as casted have acceptable corrosion resistance and almost the same critical pitting temperature. Alloy 625 as forged has the best corrosion resistance and the highest critical pitting temperature among all test specimens. Also, the corrosion behavior was evaluated in accordance with ASTM G28 standard. The corrosion rate of single layer weld overlay was unacceptable. The average corrosion rate of two layers weld overlay and in casted condition were 35.82 and 33.01 mpy, respectively. [German] Nickellegierungen sind aufgrund ihres exzellenten Korrosionswiderstandes eine bedeutende Werkstoffklasse. In der diesem Beitrag zugrunde liegenden Studie wurden mittels WIG-Schweissens ein- und zweilagige Schweissplattierungen auf den Kohlenstoffstahl A516 (Grade 70) aufgebracht. Die Vermischung in Form des Fe-, Ni-, Mo- und Nb-Gehaltes wurde an 30 Punkten der Schweissplattierungen berechnet. Die mikrostrukturellen Untersuchungen ergaben, dass die Legierung 625 eine austenitische Struktur mit zwei Arten von

  12. Standard Practice for Analysis and Interpretation of Light-Water Reactor Surveillance Results, E706(IA)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2001-01-01

    1.1 This practice covers the methodology, summarized in Annex A1, to be used in the analysis and interpretation of neutron exposure data obtained from LWR pressure vessel surveillance programs; and, based on the results of that analysis, establishes a formalism to be used to evaluate present and future condition of the pressure vessel and its support structures (1-70). 1.2 This practice relies on, and ties together, the application of several supporting ASTM standard practices, guides, and methods (see Master Matrix E 706) (1, 5, 13, 48, 49). In order to make this practice at least partially self-contained, a moderate amount of discussion is provided in areas relating to ASTM and other documents. Support subject areas that are discussed include reactor physics calculations, dosimeter selection and analysis, and exposure units. Note 1—(Figure 1 is deleted in the latest update. The user is refered to Master Matrix E 706 for the latest figure of the standards interconnectivity). 1.3 This practice is restri...

  13. The new ASTM Manual for scrubber linings the evolution of a consensus guide

    International Nuclear Information System (INIS)

    Spires, G.V.; Cavallo, J.R.

    1984-01-01

    Faced with spiraling fuel oil costs, power utilities turned to abundant and inexpensive domestic coal and lignite. Conversions and new units designed to burn solid fossil fuels were pursued at a near crisis pace to get out from under the economic penalties associated with the continued use of oil. Coal contains much more sulfur than oil; EPA limitations on SO 2 necessitated costly flue gas desulfurization (FGD) systems when burning coal. Scrubbed gas presented a particularly corrosive environment in and downstream from the FGD system. Problems which often accompany a new technology were soon evident. Materials and linings initially selected were often seen to be inadequate. Severe and rapid degradation was commonplace. This paper traces the development of the recently published ASTM Manual of Protective Linings From Flue Gas Desulfurization System. The scope of the Manual is outlined and some of the more commonly used FGD lining systems are reviewed. Finally some views on the impact of foreseeable changes in regulations and FGD technology on the use and maintenance of FGD system linings are discussed

  14. Standard Guide for Wet Sieve Analysis of Ceramic Whiteware Clays

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This guide covers the wet sieve analysis of ceramic whiteware clays. This guide is intended for use in testing shipments of clay as well as for plant control tests. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  15. 76 FR 1459 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM International

    Science.gov (United States)

    2011-01-10

    ... Production Act of 1993-ASTM International Notice is hereby given that, on December 6, 2010, pursuant to.... (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with the...

  16. Fracture toughness of welded joints of ASTM A543 steel plate

    International Nuclear Information System (INIS)

    Susukida, H.; Uebayashi, T.; Yoshida, K.; Ando, Y.

    1977-01-01

    Fracture toughness and weldability tests have been performed on a high strength steel which is a modification of ASTM A543 Grade B Class 1 steel, with a view to using it for nuclear reactor containment vessels. The results showed that fracture toughness of welded joints of ASTM A543 modified high strength steel is superior and the steel is suitable for manufacturing the containment vessels

  17. Standards in capstone design courses and the engineering curriculum.

    Science.gov (United States)

    Goldberg, Jay

    2012-01-01

    In 1990, I was the group leader of Research and Development for Surgitek, a urological device manufacturer in Racine, Wisconsin, which was the market leader in ureteral stents. I recognized the need for an industry standard for ureteral stents, felt that taking a leadership role in the development of a new standard would be a good professional development activity, and volunteered to serve as the chair of the American Society for Testing and Materials (ASTM, now known as ASTM International) Task Group on Ureteral Stents. After several years, the standard was approved, and I continue to serve as the chair of the ASTM Subcommittee on Urological Materials and Devices. This experience helped me understand the value of industry standards, expanded my professional network and visibility within the medical device industry, and helped develop my leadership skills.

  18. Status of Standardization Projects

    Science.gov (United States)

    1993-12-31

    A5 B 942 943 943 ASM SA 69 D, 8115 056; ASTM D 5118 FABRICATION OF FIBERBOARD SM AS B 941 943 943 A SM SA 69 Di- N 8115 0562 ASTM D 5168 FAB AND...DR&E(AR)759 STANDARDIZATION PROJECTS REPORT - 1ST QTR FY 1994 PREPARING ACTIVITY LISTING PA AAPAA p BPP .A- G/ASA NC AC 21 RC G CSOL- Qý yqFyýFT7RL AL...941 943 943 A SM SA 69 DH N 8115 0562 ASTM D 5168 FAB AND CLOSURE TRIPLE WALL SM AS B 941 943 943 A SM SA 69 DH N 8125 0379 V’L-B-61000 BOTTLES

  19. Standard guide for design criteria for plutonium gloveboxes

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This guide defines criteria for the design of glovebox systems to be used for the handling of plutonium in any chemical or physical form or isotopic composition or when mixed with other elements or compounds. Not included in the criteria are systems auxiliary to the glovebox systems such as utilities, ventilation, alarm, and waste disposal. Also not addressed are hot cells or open-face hoods. The scope of this guide excludes specific license requirements relating to provisions for criticality prevention, hazards control, safeguards, packaging, and material handling. Observance of this guide does not relieve the user of the obligation to conform to all federal, state, and local regulations for design and construction of glovebox systems. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user...

  20. State Standards and State Assessment Systems: A Guide to Alignment. Series on Standards and Assessments.

    Science.gov (United States)

    La Marca, Paul M.; Redfield, Doris; Winter, Phoebe C.

    Alignment of content standards, performance standards, and assessments is crucial. This guide contains information to assist states and districts in aligning their assessment systems to their content and performance standards. It includes a review of current literature, both published and fugitive. The research is woven together with a few basic…

  1. DOE interpretations Guide to OSH standards. Update to the Guide

    Energy Technology Data Exchange (ETDEWEB)

    1994-03-31

    Reflecting Secretary O`Leary`s focus on occupational safety and health, the Office of Occupational Safety is pleased to provide you with the latest update to the DOE Interpretations Guide to OSH Standards. This Guide was developed in cooperation with the Occupational Safety and Health Administration, which continued it`s support during this last revision by facilitating access to the interpretations found on the OSHA Computerized Information System (OCIS). This March 31, 1994 update contains 123 formal in letter written by OSHA. As a result of the unique requests received by the 1-800 Response Line, this update also contains 38 interpretations developed by DOE. This new occupational safety and health information adds still more important guidance to the four volume reference set that you presently have in your possession.

  2. DOE interpretations Guide to OSH standards. Update to the Guide

    Energy Technology Data Exchange (ETDEWEB)

    1994-03-31

    Reflecting Secretary O`Leary`s focus on occupational safety and health, the Office of Occupational Safety is pleased to provide you with the latest update to the DOE Interpretations Guide to OSH Standards. This Guide was developed in cooperation with the Occupational Safety and Health Administration, which continued its support during this last revision by facilitating access to the interpretations found on the OSHA Computerized Information System (OCIS). This March 31, 1994 update contains 123 formal interpretation letters written by OSHA. As a result of the unique requests received by the 1-800 Response Line, this update also contains 38 interpretations developed by DOE. This new occupational safety and health information adds still more important guidance to the four volume reference set that you presently have in your possession.

  3. DOE interpretations Guide to OSH standards. Update to the Guide

    Energy Technology Data Exchange (ETDEWEB)

    1994-03-31

    Reflecting Secretary O`Leary`s focus on occupational safety and health, the Office of Occupational Safety is pleased to provide you with the latest update to the DOE Interpretations Guide to OSH Standards. This Guide was developed in cooperation with the Occupational Safety and Health Administration, which continued its support during this last revision by facilitating access to the interpretations found on the OSHA Computerized Information System (OCIS). This March 31, 1994 update contains 123 formal interpretation letters written OSHA. As a result of the unique requests received by the 1-800 Response Line, this update also contains 38 interpretations developed by DOE. This new occupational safety and health information adds still more important guidance to the four volume reference set that you presently have in your possession.

  4. 78 FR 21850 - Federal Motor Vehicle Safety Standards; Matters Incorporated by Reference

    Science.gov (United States)

    2013-04-12

    ... to the 1985 Annual Book of ASTM Standards, Vol. 05.04, ``Test Methods for Rating Motor, Diesel... for Rating Motor, Diesel, Aviation Fuels, A2. Reference Materials and Blending Accessories, (``ASTM... [Docket No. NHTSA-2011-0185] RIN 2127-AL25 Federal Motor Vehicle Safety Standards; Matters Incorporated by...

  5. Improved ASTM G72 Test Method for Ensuring Adequate Fuel-to-Oxidizer Ratios

    Science.gov (United States)

    Juarez, Alfredo; Harper, Susana Tapia

    2016-01-01

    The ASTM G72/G72M-15 Standard Test Method for Autogenous Ignition Temperature of Liquids and Solids in a High-Pressure Oxygen-Enriched Environment is currently used to evaluate materials for the ignition susceptibility driven by exposure to external heat in an enriched oxygen environment. Testing performed on highly volatile liquids such as cleaning solvents has proven problematic due to inconsistent test results (non-ignitions). Non-ignition results can be misinterpreted as favorable oxygen compatibility, although they are more likely associated with inadequate fuel-to-oxidizer ratios. Forced evaporation during purging and inadequate sample size were identified as two potential causes for inadequate available sample material during testing. In an effort to maintain adequate fuel-to-oxidizer ratios within the reaction vessel during test, several parameters were considered, including sample size, pretest sample chilling, pretest purging, and test pressure. Tests on a variety of solvents exhibiting a range of volatilities are presented in this paper. A proposed improvement to the standard test protocol as a result of this evaluation is also presented. Execution of the final proposed improved test protocol outlines an incremental step method of determining optimal conditions using increased sample sizes while considering test system safety limits. The proposed improved test method increases confidence in results obtained by utilizing the ASTM G72 autogenous ignition temperature test method and can aid in the oxygen compatibility assessment of highly volatile liquids and other conditions that may lead to false non-ignition results.

  6. ASTM E 1559 method for measuring material outgassing/deposition kinetics has applications to aerospace, electronics, and semiconductor industries

    Science.gov (United States)

    Garrett, J. W.; Glassford, A. P. M.; Steakley, J. M.

    1994-01-01

    The American Society for Testing and Materials has published a new standard test method for characterizing time and temperature-dependence of material outgassing kinetics and the deposition kinetics of outgassed species on surfaces at various temperatures. This new ASTM standard, E 1559(1), uses the quartz crystal microbalance (QCM) collection measurement approach. The test method was originally developed under a program sponsored by the United States Air Force Materials Laboratory (AFML) to create a standard test method for obtaining outgassing and deposition kinetics data for spacecraft materials. Standardization by ASTM recognizes that the method has applications beyond aerospace. In particular, the method will provide data of use to the electronics, semiconductor, and high vacuum industries. In ASTM E 1559 the material sample is held in vacuum in a temperature-controlled effusion cell, while its outgassing flux impinges on several QCM's which view the orifice of the effusion cell. Sample isothermal total mass loss (TML) is measured as a function of time from the mass collected on one of the QCM's which is cooled by liquid nitrogen, and the view factor from this QCM to the cell. The amount of outgassed volatile condensable material (VCM) on surfaces at higher temperatures is measured as a function of time during the isothermal outgassing test by controlling the temperatures of the remaining QCM's to selected values. The VCM on surfaces at temperatures in between those of the collector QCM's is determined at the end of the isothermal test by heating the QCM's at a controlled rate and measuring the mass loss from the end of the QCM's as a function of time and temperature. This reevaporation of the deposit collected on the QCM's is referred to as QCM thermogravimetric analysis. Isothermal outgassing and deposition rates can be determined by differentiating the isothermal TML and VCM data, respectively, while the evaporation rates of the species can be obtained as a

  7. CSA guide to Canadian wind turbine codes and standards

    International Nuclear Information System (INIS)

    2008-01-01

    The Canadian wind energy sector has become one of the fastest-growing wind energy markets in the world. Growth of the industry has been supported by various government agencies. However, many projects have experienced cost over-runs or cancellations as a result of unclear regulatory requirements, and wind energy developers are currently subject to a variety of approval processes involving several different authorities. This Canadian Standards Association (CSA) guide provided general information on codes and standards related to the design, approval, installation, operation, and maintenance of wind turbines in Canada. CSA codes and standards were developed by considering 5 new standards adopted by the International Electrotechnical Commission (IEC) Technical Committee on Wind Turbines. The standards described in this document related to acoustic noise measurement techniques; power performance measurements of electricity-producing wind turbines; lightning protection for wind turbine generator systems; design requirements for turbines; and design requirements for small wind turbines. The guide addressed specific subject areas related to the development of wind energy projects that involve formal or regulatory approval processes. Subject areas included issues related to safety, environmental design considerations, site selection, and mechanical systems. Information on associated standards and codes was also included

  8. Verification of the ASTM G-124 Purge Equation

    Science.gov (United States)

    Robbins, Katherine E.; Davis, Samuel Eddie

    2009-01-01

    ASTM G-124 seeks to evaluate combustion characteristics of metals in high-purity (greater than 99%) oxygen atmospheres. ASTM G-124 provides the following equation to determine the minimum number of purges required to reach this level of purity in a test chamber: n = -4/log10(Pa/Ph), where "n" is the total number of purge cycles required, Ph is the absolute pressure used for the purge on each cycle and Pa is the atmospheric pressure or the vent pressure. The origin of this equation is not known and has been the source of frequent questions as to its accuracy and reliability. This paper shows the derivation of the G-124 purge equation, and experimentally explores the equation to determine if it accurately predicts the number of cycles required.

  9. 78 FR 79319 - Amendment to Standards and Practices for All Appropriate Inquiries Under CERCLA

    Science.gov (United States)

    2013-12-30

    ... Standard? The ASTM E1527-13 standard is similar to the ASTM E1527-05 standard in format, process, and areas... under Section 553 of the Administrative Procedure Act (APA) for this revision to become effective immediately. Section 553(d)(3) of the APA allows an effective date less than 30 days after publication ``as...

  10. Overview and comparative study of GPR international standards and guidelines - COST Action TU1208

    Science.gov (United States)

    Pajewski, Lara; Marciniak, Marian; Benedetto, Andrea; Tosti, Fabio

    2016-04-01

    Ground Penetrating Radar (GPR) can be effectively used for non-destructive testing of composite structures and diagnostics affecting the whole life-cycle of civil engineering works. Nevertheless, few recognised international standards exist in this field and inhomogeneous recommendations are present in different countries. Moreover, the levels of knowledge, awareness and experience regarding the use of GPR in civil engineering vary strongly across different European areas. The COST Action TU1208 is working hard on leveraging these differences, by sharing and disseminating knowledge and experience, as well as by developing guidelines and protocols for a safe and effective use of GPR in civil engineering. GPR users need to know which is the best way to conduct GPR measurements and what the quality level for the results should be. The TU1208 guidelines will ensure a higher efficiency and quality of GPR services and they will constitute a scientific basis for the introduction of European Standards on the application of GPR in civil engineering. The aim of this contribution is to present an in-depth overview and critical analysis of the existing GPR international and national standards and guidelines. The main documents considered in our work are listed and briefly described in the following. Three standards are provided by the American Society for Testing and Materials (ASTM), to guide the GPR use for subsurface investigation, evaluation of asphalt-covered concrete bridge decks, and determination of pavement-layer thickness: 1. ASTM D6432-11, Standard Guide for Using the Surface Ground Penetrating Radar Method for Subsurface Investigation, ASTM International, West Conshohocken, PA, 2011, www.astm.org, DOI: 10.1520/D6432-11. 2. ASTM D6087-08, Standard Test Method for Evaluating Asphalt-Covered Concrete Bridge Decks Using Ground Penetrating Radar, ASTM International, West Conshohocken, PA, 2008, www.astm.org, DOI: 10.1520/D6087-08. 3. ASTM D4748-10, Standard Test Method

  11. Comparative study between EDXRF and ASTM E572 methods using two-way ANOVA

    Science.gov (United States)

    Krummenauer, A.; Veit, H. M.; Zoppas-Ferreira, J.

    2018-03-01

    Comparison with reference method is one of the necessary requirements for the validation of non-standard methods. This comparison was made using the experiment planning technique with two-way ANOVA. In ANOVA, the results obtained using the EDXRF method, to be validated, were compared with the results obtained using the ASTM E572-13 standard test method. Fisher's tests (F-test) were used to comparative study between of the elements: molybdenum, niobium, copper, nickel, manganese, chromium and vanadium. All F-tests of the elements indicate that the null hypothesis (Ho) has not been rejected. As a result, there is no significant difference between the methods compared. Therefore, according to this study, it is concluded that the EDXRF method was approved in this method comparison requirement.

  12. Evaluation of Instrumentation for Measuring Undissolved Water in Aviation Turbine Fuels per ASTM D3240

    Science.gov (United States)

    2015-11-05

    Undissolved Water in Aviation Turbine Fuels per ASTM D3240 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Joel Schmitigal... water ) in Aviation Turbine Fuels per ASTM D3240 15. SUBJECT TERMS fuel, JP-8, aviation fuel, contamination, free water , undissolved water , Aqua-Glo 16...Michigan 48397-5000 Evaluation of Instrumentation for Measuring Undissolved Water in Aviation Turbine Fuels per ASTM D3240 Joel Schmitigal Force

  13. White Paper Summary of 2nd ASTM International Workshop on Hydrides in Zirconium Alloy Cladding

    Energy Technology Data Exchange (ETDEWEB)

    Sindelar, R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Louthan, M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); PNNL, B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-05-29

    This white paper recommends that ASTM International develop standards to address the potential impact of hydrides on the long term performance of irradiated zirconium alloys. The need for such standards was apparent during the 2nd ASTM International Workshop on Hydrides in Zirconium Alloy Cladding and Assembly Components, sponsored by ASTM International Committee C26.13 and held on June 10-12, 2014, in Jackson, Wyoming. The potentially adverse impacts of hydrogen and hydrides on the long term performance of irradiated zirconium-alloy cladding on used fuel were shown to depend on multiple factors such as alloy chemistry and processing, irradiation and post irradiation history, residual and applied stresses and stress states, and the service environment. These factors determine the hydrogen content and hydride morphology in the alloy, which, in turn, influence the response of the alloy to the thermo-mechanical conditions imposed (and anticipated) during storage, transport and disposal of used nuclear fuel. Workshop presentations and discussions showed that although hydrogen/hydride induced degradation of zirconium alloys may be of concern, the potential for occurrence and the extent of anticipated degradation vary throughout the nuclear industry because of the variations in hydrogen content, hydride morphology, alloy chemistry and irradiation conditions. The tools and techniques used to characterize hydrides and hydride morphologies and their impacts on material performance also vary. Such variations make site-to-site comparisons of test results and observations difficult. There is no consensus that a single material or system characteristic (e.g., reactor type, burnup, hydrogen content, end-of life stress, alloy type, drying temperature, etc.) is an effective predictor of material response during long term storage or of performance after long term storage. Multi-variable correlations made for one alloy may not represent the behavior of another alloy exposed to

  14. Standard guide for metallographic preparation of thermal sprayed coatings

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This guide covers recommendations for sectioning, cleaning, mounting, grinding, and polishing to reveal the microstructural features of thermal sprayed coatings (TSCs) and the substrates to which they are applied when examined microscopically. Because of the diversity of available equipment, the wide variety of coating and substrate combinations, and the sensitivity of these specimens to preparation technique, the existence of a series of recommended methods for metallographic preparation of thermal sprayed coating specimens is helpful. Adherence to this guide will provide practitioners with consistent and reproducible results. Additional information concerning standard practices for metallographic preparation can be found in Practice E 3. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitatio...

  15. Overview (this manuscript is an overview of an ASTM symposium. The authors, John Sebroski and Mark Mason, of the overview were the co-chairs of the symposium and co-editors of the manuscripts submitted for ASTM peer review and subsequent publication in the technical proceedings for the symposium)

    Science.gov (United States)

    The Symposium on Developing Consensus Standards for Measuring Chemical Emissions from Spray Polyurethane Foam (SPF) Insulation was held on April 30th and May 1, 2015. Sponsored by ASTM Committee D22 on Air Quality, the symposium was held in Anaheim, CA, in conjunction with the st...

  16. Nuclear reactor pressure vessel surveillance capsule examinations. Application of American Society for Testing and Materials Standards

    International Nuclear Information System (INIS)

    Perrin, J.S.

    1978-01-01

    A series of pressure vessel surveillance capsules is installed in each commercial nuclear power plant in the United States. A capsule typically contains neutron dose meters, thermal monitors, tensile specimens, and Charpy V-notch impact specimens. In order to determine property changes of the pressure vessel resulting from irradiation, surveillance capsules are periodically removed during the life of a reactor and examined. There are numerous standards, regulations, and codes governing US pressure vessel surveillance capsule programmes. These are put out by the US Nuclear Regulatory Commission, the Boiler and Pressure Vessel Committee of the American Society of Mechanical Engineers, and the American Society for Testing and Materials (ASTM). A majority of the pertinent ASTM standards are under the jurisdiction of ASTM Committee E-10 on Nuclear Applications and Measurements of Radiation Effects. The standards, regulations, and codes pertaining to pressure vessel surveillance play an important role in ensuring reliability of the nuclear pressure vessels. ASTM E 185-73 is the Standard Recommended Practice for Surveillance Tests for Nuclear Reactors. This standard recommends procedures for both the irradiation and subsequent testing of surveillance capsules. ASTM E 185-73 references many additional specialized ASTM standards to be followed in specific areas of a surveillance capsule examination. A key element of surveillance capsule programmes is the Charpy V-notch impact test, used to define curves of fracture behaviour over a range of temperatures. The data from these tests are used to define the adjusted reference temperature used in determining pressure-temperature operating curves for a nuclear power plant. (author)

  17. Standard guide for preparation of plastics and polymeric specimens for microstructural examination

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This guide covers recommended procedures and guidelines for the preparation of plastic and polymeric specimens for microstructural examination by light and electron microscopy. 1.2 This guide is applicable to most semi-rigid and rigid plastics, including engineering plastics. This guide is also applicable to some non-rigid plastics. 1.3 The procedures and guidelines presented in this guide are those which generally produce satisfactory specimens. This guide does not describe the variations in techniques required to solve individual problems. 1.4 Many detailed descriptions of grinding and polishing of plastics and polymers are available (1-7). 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  18. Use of ASTM D5304 in assessing unstable diesel fuel

    Energy Technology Data Exchange (ETDEWEB)

    Turner, L.M.; Martin, C.J. [Defense Fuel Supply Center, Alexandria, VA (United States); Beal, E.J.; Hardy, D.R. [Naval Research Lab., Washington, DC (United States)

    1995-05-01

    The storage stability, or the length of time a fuel can be stored, is of great concern to diesel fuel users. This paper reports on the use of the new ASTM accelerated test for storage stability by oxygen overpressure (D5304) to predict future storage life span of 63,000,000 gallons of a diesel fuel for US Naval vessel use. This paper demonstrates the use of ASTM D5304 at storage times of 16, 40 and 96 hours to accurately determine the length of time that this large quantity of diesel fuel could be stored at ambient temperatures before the maximum allowable amount of particulate contamination was reached.

  19. Integration of Nanofluids into Commercial Antifreeze Concentrates with ASTM D15 Corrosion Testing

    Science.gov (United States)

    2013-05-01

    Lockwood1 1 Valvoline New Product Development Laboratory, Ashland Consumer Markets , Lexington, Kentucky. 2 Tank Automotive Research, Development...Development Laboratory,Ashland Consumer Markets ,P.O. Box 14000,Lexington,KY,40512 8. PERFORMING ORGANIZATION REPORT NUMBER ; #23826 9. SPONSORING...Technology, Performance, and Life for Light-Duty Applications, Engine Coolant Testing: Fourth Volume, ASTM STP 1335, R.E. Beale ed., ASTM, Philadelphia

  20. Standard Guide for Testing Materials for Aerospace Plastic Transparent Enclosures

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This guide is intended to summarize the standard test methods available on individual and composite materials utilized in fabrication of aerospace plastic transparent enclosures. As such, it is intended to specifically include transparent thermoplastics, transparent elastomers, and reinforced plastics, whether thermoplastic or thermosetting. 1.2 This guide is intended as an aid in the search for test methods pertinent to Aerospace Plastic Transparent Enclosures. It should be understood that all methods listed may not apply to all enclosures. 1.3 The standards included refer to the properties or aspects listed in Table 1. The properties or aspects are listed in alphabetical order and the descriptions used are intended to facilitate the search. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limi...

  1. Interlaboratory Study (ILS) for F 548-01, The Standard Test Method for Intensity of Scratches on Aerospace Transparent Plastics

    National Research Council Canada - National Science Library

    Pinkus, Alan

    2003-01-01

    ...) as outlined in ASTM E 691. This report, which conforms to the ILS reporting format required by ASTM, describes the study that was conducted for ASTM test standard F 548-01, Intensity of Scratches on Aerospace Transparent Plastics...

  2. Standard guide for installation of Walk-Through metal detectors

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 Some facilities require that personnel entering designated areas be screened for concealed weapons and other metallic materials. Also, personnel exiting designated areas are often screened for metallic shielding material and other types of metallic contraband. Walk-through metal detectors are widely used to implement these requirements. This guide describes various elements to be considered when planning to install walk-through metal detectors. 1.2 This guide is not intended to set performance levels, nor is it intended to limit or constrain operational technologies. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  3. 76 FR 78614 - Welded ASTM A-312 Stainless Steel Pipe From South Korea and Taiwan: Continuation of Antidumping...

    Science.gov (United States)

    2011-12-19

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-580-810, A-583-815] Welded ASTM A-312... revocation of the antidumping duty orders on welded ASTM A-312 stainless steel pipe from South Korea (Korea... December 30, 1992, the Department published the antidumping duty orders on welded ASTM A-312 stainless...

  4. Spray Drift Reduction Evaluations of Spray Nozzles Using a Standardized Testing Protocol

    Science.gov (United States)

    2010-07-01

    Drop Size Characteristics in a Spray Using Optical Nonimaging Light-Scattering Instruments,” Annual Book of ASTM Standards, Vol. 14-02, ASTM...Test Method for Determining Liquid Drop Size Characteristics in a Spray Using Optical Non- imaging Light-Scattering Instruments 22. AGDISP Model

  5. Sources of Confusion in the Determination of ASTM Repetitive Member Factors for the Allowable Properties of Wood Products

    Science.gov (United States)

    S. Verrill; D. Kretschmann

    2012-01-01

    It is generally accepted that there should be an upward repetitive member allowable property adjustment. ASTM D245 (2011c) and ASTM D1990 (2011b) specify a 1.15 factor for allowable bending stress. This factor is also listed in ASTM D6555 (2011a, Table 1). In this technical note, sources of confusion regarding appropriate repetitive member factors are identified. This...

  6. Cavitation erosion - corrosion behaviour of ASTM A27 runner steel in natural river water

    International Nuclear Information System (INIS)

    Tôn-Thât, L

    2014-01-01

    Cavitation erosion is still one of the most important degradation modes in hydraulic turbine runners. Part of researches in this field focuses on finding new materials, coatings and surface treatments to improve the resistance properties of runners to this phenomenon. However, only few studies are focused on the deleterious effect of the environment. Actually, in some cases a synergistic effect between cavitation erosion mechanisms and corrosion kinetics can establish and increase erosion rate. In the present study, the cavitation erosion-corrosion behaviour of ASTM A27 steel in natural river water is investigated. This paper state the approach which has been used to enlighten the synergy between both phenomena. For this, a 20 kHz vibratory test according ASTM G32 standard is coupled to an electrochemical cell to be able to follow the different corrosion parameters during the tests to get evidence of the damaging mechanism. Moreover, mass losses have been followed during the exposure time. The classical degradation parameters (cumulative weight loss and erosion rate) are determined. Furthermore, a particular effort has been implemented to determine the evolution of surface damages in terms of pitting, surface cracking, material removal and surface corrosion. For this, scanning electron microscopy has been used to link the microstructure to the material removal mechanisms

  7. 76 FR 67673 - Welded ASTM A-312 Stainless Steel Pipe From South Korea and Taiwan: Final Results of Expedited...

    Science.gov (United States)

    2011-11-02

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-580-810, A-583-815] Welded ASTM A-312... the antidumping duty orders on welded ASTM A-312 stainless steel pipe from South Korea and Taiwan... duty orders on welded ASTM A-312 stainless steel pipe from South Korea and Taiwan pursuant to section...

  8. A Knowledge- Based Computer System for UO2 Characterization According to ASTM Requirements

    International Nuclear Information System (INIS)

    Afifi, Y.K.; El-Hakim, E.

    2000-01-01

    The uranium dioxde (UO 2 ) powder properties and the pellets fabrication processes determine the characteristics of the sintered UO 2 pellets. The powder properties include chemical and physical characteristics. The physical and chemical properties of UO 2 powder are normally checked to ensure consistency and reproducibility of the sintered UO 2 pellets. Powder characteristics are known to influence the subsequent manufacturing performance or the fuel properties. The aim of this paper is to provide the nuclear industry with a program dealing with the processes and the related requirements to determine the specifications of UO 2 powder according to the American Standards for Testing and Materials (ASTM). This program covers the physical and chemical characteristics of UO 2 powder. A group of logic flow charts dealing with the data and information available in the ASTM for each step in the characterization of UO 2 powder process and the technical assistance are constructed. These logic flow charts are collected to form a module of the software to qualify the UO 2 powder. The program contains 8 modules, each one deals with one object. This program saves time, is also considered as a collective schema for all the required UO 2 powder characterization and the related processes, and could be used as a training tool for less skilled personnel involved in UO 2 powder characterization laboratories

  9. Standard Guide for Specifying Thermal Performance of Geothermal Power Systems

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This guide covers power plant performance terms and criteria for use in evaluation and comparison of geothermal energy conversion and power generation systems. The special nature of these geothermal systems makes performance criteria commonly used to evaluate conventional fossil fuel-fired systems of limited value. This guide identifies the limitations of the less useful criteria and defines an equitable basis for measuring the quality of differing thermal cycles and plant equipment for geothermal resources. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. An Automated Safe-to-Mate (ASTM) Tester

    Science.gov (United States)

    Nguyen, Phuc; Scott, Michelle; Leung, Alan; Lin, Michael; Johnson, Thomas

    2013-01-01

    Safe-to-mate testing is a common hardware safety practice where impedance measurements are made on unpowered hardware to verify isolation, continuity, or impedance between pins of an interface connector. A computer-based instrumentation solution has been developed to resolve issues. The ASTM is connected to the circuit under test, and can then quickly, safely, and reliably safe-to-mate the entire connector, or even multiple connectors, at the same time.

  11. Stress corrosion (Astm G30-90 standard) in 08x18H10T stainless steel of nuclear fuel storage pool in WWER reactors; Corrosion bajo esfuerzo (Norma ASTM G30-90) en acero inoxidable 08x18H10T de piscinas de almacenamiento de combustible nuclear en reactores V.V.E.R

    Energy Technology Data Exchange (ETDEWEB)

    Herrera, V.; Zamora R, L. [Centro de Estudios Aplicados al Desarrollo Nuclear (Cuba)

    1997-07-01

    At the water storage of the irradiated nuclear fuel has been an important factor in its management. The actual pools have its walls covered with inoxidable steel and heat exchangers to dissipate the residual heat from fuel. It is essential to control the water purity to eliminate those conditions which aid to the corrosion process in fuel and at related components. The steel used in this research was obtained from an austenitic inoxidizable steel standardized with titanium 08x18H10T (Type 321) similar to one of the two steel coatings used to cover walls and the pools floor. the test consisted in the specimen deformation through an U ply according to the Astm G30-90 standard. The exposition of the deformed specimen it was realized in simulated conditions to the chemical regime used in pools. (Author)

  12. Standard test method for guided bend test for ductility of welds

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers a guided bend test for the determination of soundness and ductility of welds in ferrous and nonferrous products. Defects, not shown by X rays, may appear in the surface of a specimen when it is subjected to progressive localized overstressing. This guided bend test has been developed primarily for plates and is not intended to be substituted for other methods of bend testing. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. Note 1—For additional information see Terminology E 6, and American Welding Society Standard D 1.1. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  13. Standard guide for conducting and evaluating galvanic corrosion tests in electrolytes

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1981-01-01

    1.1 This guide covers conducting and evaluating galvanic corrosion tests to characterize the behavior of two dissimilar metals in electrical contact in an electrolyte under low-flow conditions. It can be adapted to wrought or cast metals and alloys. 1.2 This guide covers the selection of materials, specimen preparation, test environment, method of exposure, and method for evaluating the results to characterize the behavior of galvanic couples in an electrolyte. Note 1—Additional information on galvanic corrosion testing and examples of the conduct and evaluation of galvanic corrosion tests in electrolytes are given in Refs (1) through (7). 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicabil...

  14. Comparison of the General Electric BWR/6 standard plant design to the IAEA NUSS codes and guides

    International Nuclear Information System (INIS)

    D'Ardenne, W.H.; Sherwood, G.G.

    1985-01-01

    The General Electric BWR/6 Mark III standard plant design meets or exceeds current requirements of published International Atomic Energy Agency (IAEA) Nuclear Safety Standards (NUSS) codes and guides. This conclusion is based on a review of the NUSS codes and guides by General Electric and by the co-ordinated US review of the NUSS codes and guides during their development. General Electric compared the published IAEA NUSS codes and guides with the General Electric design. The applicability of each code and guide to the BWR/6 Mark III standard plant design was determined. Each code or guide was reviewed by a General Electric engineer knowledgeable about the structures, systems and components addressed and the technical area covered by that code or guide. The results of this review show that the BWR/6 Mark III standard plant design meets or exceeds the applicable requirements of the published IAEA NUSS codes and guides. The co-ordinated US review of the IAEA NUSS codes and guides corroborates the General Electric review. In the co-ordinated US review, the USNRC and US industry organizations (including General Electric) review the NUSS codes and guides during their development. This review ensures that the NUSS codes and guides are consistent with the current US government regulations, guidance and regulatory practices, US voluntary industry codes and standards, and accepted US industry design, construction and operational practices. If any inconsistencies are identified, comments are submitted to the IAEA by the USNRC. All US concerns submitted to the IAEA have been resolved. General Electric design reviews and the Final Design Approval (FDA) issued by the USNRC have verified that the General Electric BWR/6 Mark III standard plant design meets or exceeds the current US requirements, guidance and practices. Since these requirements, guidance and practices meet or exceed those of the NUSS codes and guides, so does the General Electric design. (author)

  15. Standard guide for reflected–light photomicrography

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This guide outlines various methods which may be followed in the photography of metals and materials with the reflected-light microscope. Methods are included for preparation of prints and transparencies in black-and-white and in color, using both direct rapid and wet processes. 1.2 Guidelines are suggested to yield photomicrographs of typical subjects and, to the extent possible, of atypical subjects as well. Information is included concerning techniques for the enhanced display of specific material features. Descriptive material is provided where necessary to clarify procedures. References are cited where detailed descriptions may be helpful. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use. Specific precautionary statements are given in X1.7. 1.4 The sections appear ...

  16. Testing of adsorbents used in nuclear power plant air cleaning systems using the open-quotes Newclose quotes standards

    International Nuclear Information System (INIS)

    Freeman, W.P.

    1993-01-01

    Ever since the publication of the NRC Information Notice No. 87-32: Deficiencies in the Testing of Nuclear-Grade Activated Charcoal, nuclear power facilities in the US have struggled in their efforts to open-quotes...review the information for applicability to their facilities and consider action, if appropriate ...close quotes as stated in the notice. The encouragement of resident NRC inspectors at some nuclear power facilities has prompted a variety of responses ranging from no change at all in testing requirements to contemplated changes in plant technical specifications. This confusion is the result of a couple factors. The first factor is the lack of a current revision to NRC Regulatory Guide 1.52, the basic document used in nuclear power plant technical specifications for the testing of engineered-safety feature (ESF) post accident air cleaning systems. The second factor is the standards that have been written since the last revision of Reg. Guide 1.52 which include two revision of ANSI N509 and N510, two revisions of RDT M16-1T, two version of ASTM D3803, two versions of ASTM D4069, and three versions of an SME code AG-1. Few of the standards and codes listed above are commensurate with each other and, thus, present a nearly insolvable maze to the HVAC engineer asked to upgrade adsorbent testing requirements following the standards. This paper describes the authors experience with a number of nuclear power facilities in their efforts to meet the requirements of the new standards of testing adsorbents from nuclear power plant air cleaning systems. The existing standards are discussed in light of the current state of the art for adsorbent testing of adsorbent media from nuclear air treatment systems. Test results are presented showing the impact of new test requirements on acceptance criteria when compared to the old test requirements and recommendations are offered for solution of this testing problem in the future. 12 refs., 5 tabs

  17. Combating Wear of ASTM A36 Steel by Surface Modification Using Thermally Sprayed Cermet Coatings

    Directory of Open Access Journals (Sweden)

    Vineet Shibe

    2016-01-01

    Full Text Available Thermal spray coatings can be applied economically on machine parts to enhance their requisite surface properties like wear, corrosion, erosion resistance, and so forth. Detonation gun (D-Gun thermal spray coatings can be applied on the surface of carbon steels to improve their wear resistance. In the present study, alloy powder cermet coatings WC-12% Co and Cr3C2-25% NiCr have been deposited on ASTM A36 steel with D-Gun thermal spray technique. Sliding wear behavior of uncoated ASTM A36 steel and D-Gun sprayed WC-12% Co and Cr3C2-25% NiCr coatings on base material is observed on a Pin-On-Disc Wear Tester. Sliding wear performance of WC-12% Co coating is found to be better than the Cr3C2-25% NiCr coating. Wear performance of both these cermet coatings is found to be better than uncoated ASTM A36 steel. Thermally sprayed WC-12% Co and Cr3C2-25% NiCr cermet coatings using D-Gun thermal spray technique is found to be very useful in improving the sliding wear resistance of ASTM A36 steel.

  18. Impact of heat treatment on HSS cutting tool (ASTM A600) and its behaviour during machining of mild steel (ASTM A36)

    Science.gov (United States)

    Afolalu, S. A.; Abioye, O. P.; Salawu, E. Y.; Okokpujie, I. P.; Abioye, A. A.; Omotosho, O. A.; Ajayi., O. O.

    2018-04-01

    Carburization is one the best heat treatment that responded well to hardening with Palm Kernel Shell giving the best hardness value. This work studied the influence of carburization on HSStool(ASTM A600) and its behaviour during machining of mild steel (ASTM A36). Composition of the samples (12 pieces of 180 × 12 × 12 mm) HSS tools were checked using UV-VIS spectrometer and the tools were carburized with PKS at holding temperatures and time of 800, 850, 900, 950 °C and 60,90 120 minutes using muffle furnance. The micro structural analysis, surface and core hardnessof the treated samples gave better results than the untreated samples when checked withsoft driven and optical microscope. It wasalso observed that increase in the feed rate and depth for length of cut of 50 mm significantly reduces the wear progression and thereby gave best machining time at maximum carburizing temperature and time(950 °C / 120 minutes) when it was used to cut mild steelon the lathe machine.

  19. JST Thesaurus Headwords and Synonyms: ASTM [MeCab user dictionary for science technology term[Archive

    Lifescience Database Archive (English)

    Full Text Available MeCab user dictionary for science technology term ASTM 名詞 一般 * * * * 米国材料試験協会 ベイコクザ...イリョウシケンキョウカイ ベイコクザイリョーシケンキョーカイ Thesaurus2015 200906091611619997 C IA02 UNKNOWN_1 ASTM

  20. Ductile fracture toughness of heavy section pressure vessel steel plate. A specimen-size study of ASTM A 533 steels

    International Nuclear Information System (INIS)

    Williams, J.A.

    1979-09-01

    The ductile fracture toughness, J/sub Ic/, of ASTM A 533, Grade B, Class 1 and ASTM A 533, heat treated to simulate irradiation, was determined for 10- to 100-mm thick compact specimens. The toughness at maximum specimen load was also measured to determine the conservatism of J/sub Ic/. The toughness of ASTM A 533, Grade B, Class 1 steel was 349 kJ/m 2 and at the equivalent upper shelf temperature, the heat treated material exhibited 87 kJ/m 2 . The maximum load fracture toughness was found to be linearly proportional to specimen size, and only specimens which failed to meet ASTM size criteria exhibited maximum load toughness less than J/sub Ic/

  1. Standard Guide for Packaging Materials for Foods to Be Irradiated

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This guide provides a format to assist producers and users of food packaging materials in selecting materials that have the desirable characteristics for their intended use and comply with applicable standards or government authorizations. It outlines parameters that should be considered when selecting food-contact packaging materials intended for use during irradiation of prepackaged foods and it examines the criteria for fitness for their use. 1.2 This guide identifies known regulations and regulatory frameworks worldwide pertaining to packaging materials for holding foods during irradiation; but it does not address all regulatory issues associated with the selection and use of packaging materials for foods to be irradiated. It is the responsibility of the user of this guide to determine the pertinent regulatory issues in each country where foods are to be irradiated and where irradiated foods are distributed. 1.3 This guide does not address all of the food safety issues associated with the synergisti...

  2. An Experimental Copyright Moratorium: Study of a Proposed Solution to the Copyright Photocopying Problem. Final Report to the American Society for Testing and Materials (ASTM).

    Science.gov (United States)

    Heilprin, Laurence B.

    The Committee to Investigate Copyright Problems (CICP), a non-profit organization dedicated to resolving the conflict known as the "copyright photocopying problem" was joined by the American Society for Testing and Materials (ASTM), a large national publisher of technical and scientific standards, in a plan to simulate a long-proposed…

  3. 75 FR 70074 - Consensus Standards, Light-Sport Aircraft

    Science.gov (United States)

    2010-11-16

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Consensus Standards, Light-Sport... accepted consensus standards relating to the provisions of the Sport Pilot and Light-Sport Aircraft rule issued July 16, 2004, and effective September 1, 2004. ASTM International Committee F37 on Light Sport...

  4. Standard practice for analysis and interpretation of physics dosimetry results for test reactors

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    This practice describes the methodology summarized in Annex Al to be used in the analysis and interpretation of physics-dosimetry results from test reactors. This practice relies on, and ties together, the application of several supporting ASTM standard practices, guides, and methods that are in various stages of completion (see Fig. 1). Support subject areas that are discussed include reactor physics calculations, dosimeter selection and analysis, exposure units, and neutron spectrum adjustment methods. This practice is directed towards the development and application of physics-dosimetrymetallurgical data obtained from test reactor irradiation experiments that are performed in support of the operation, licensing, and regulation of LWR nuclear power plants. It specifically addresses the physics-dosimetry aspects of the problem. Procedures related to the analysis, interpretation, and application of both test and power reactor physics-dosimetry-metallurgy results are addressed in Practice E 853, Practice E 560, Matrix E 706(IE), Practice E 185, Matrix E 706(IG), Guide E 900, and Method E 646

  5. Isothermal Bainite Processing of ASTM A723 Components

    Science.gov (United States)

    1993-09-01

    4 List of Illustrations 1. Photograph of typical cylinders used in the present study ................................. 7 2. CCT diagram for... CCT ) diagram obtained by thermal and magnetic analyses for the high nickel (-3 percent) ASTM A723 steel. The bainite knee for the 2 percent nickel...block. Also shown is the slope giving the average cooling rate in the critical region of the CCT diagram . This average rate happens to approximately

  6. A compendium of major US radiation protection standards and guides

    International Nuclear Information System (INIS)

    Mills, W.A.; Flack, D.S.; Arsenault, F.J.; Conti, E.F.

    1988-07-01

    Following discussion of the general issue, the CIRRPC Executive Committee approved, with concurrence of the full Committee, an Oak Ridge Associated Universities (ORAU) staff proposal to develop a compendium of Fact Sheets on the major US radiation protection standards and guides, existing or proposed. The compendium contains relevant legal or statutory information and detailed technical requirements that state and describe the protection to be achieved. The report provides appropriate legislative citations; notes any legislative language that gave direction to the development of standards promulgated under the legislation; cites rationales for the standards promulgated; and provides a listing of related standards. Two consultants with considerable experience in radiation protection regulations were contracted to assist the ORAU staff in developing the report. This report has been reviewed twice by the CIRRPC member agencies; once to ensure the accuracy of all the legal and technical facts in the compendium, and once to comment on the entire document, including the accompanying text. This final report reflects consideration of all the agencies' comments received during the reviews. Part I of this report presents information on the selection, preparation and content of the Fact Sheets; an overview of their scopes, applications and modes of control; and the ORAU conclusions and recommendations. Part II contains the Fact Sheets and a User's Guide to finding relevant information in the Fact Sheets

  7. 78 FR 13243 - Updates to Standards Incorporated by Reference; Reapproved ASTM Standards; Technical Amendment

    Science.gov (United States)

    2013-02-27

    ... Characteristics of Plastic Film 2009)[egr]1. and Sheeting. Standard Specification for F682-82a F682-82a 46 56.01-2... (Reapproved Standard Test Method for Determining Gas 2009)[egr]1. Permeability Characteristics of Plastic Film... Permeability Characteristics of Plastic Film and Sheeting (approved May 1, 2009), incorporation by reference...

  8. Cor ASTM: um método simples e rápido para determinar a qualidade do biodiesel produzido a partir de óleos residuais de fritura ASTM color: a simple and fast method for determining quality of biodiesel produced from used cooking oils

    Directory of Open Access Journals (Sweden)

    Verônica Santos de Morais

    2013-01-01

    Full Text Available In this study, 23 biodiesel samples were produced, 20 from used cooking oil and the remaining 3 from refined soybean oil. The following properties were determined in all of the samples (oil and its respective biodiesel: density; viscosity; total acid number and ASTM color. The results indicated high correlation (R > 0.6 between ASTM color of used cooking oil and total acid number of its resultant biodiesel. This high correlation allows prediction of the quality of the biodiesel produced using a simple and fast procedure such as ASTM color.

  9. 75 FR 48593 - Pipeline Safety: Periodic Updates of Regulatory References to Technical Standards and...

    Science.gov (United States)

    2010-08-11

    ... (ASTM): ASTM A53/A53M-07 (2007), ``Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless'' (September 1, 2007). Replaces IBR: 2004 edition; Referenced in 49 CFR 192...), we clarify that cast iron, malleable iron, or ductile iron may be used in the valve ball or plug...

  10. Final Report, Volume 2, The Development of Qualification Standards for Cast Duplex Stainless Steel

    Energy Technology Data Exchange (ETDEWEB)

    Russell, Steven, W.; Lundin, Carl, D.

    2005-09-30

    The scope of testing cast Duplex Stainless Steel (DSS) required testing to several ASTM specifications, while formulating and conducting industry round robin tests to verify and study the reproducibility of the results. ASTM E562 (Standard Test Method for Determining Volume Fraction by Systematic manual Point Count) and ASTM A923 (Standard Test Methods for Detecting Detrimental Intermetallic Phase in Wrought Duplex Austenitic/Ferritic Stainless Steels) were the specifications utilized in conducting this work. An ASTM E562 industry round robin, ASTM A923 applicability study, ASTM A923 industry round robin, and an ASTM A923 study of the effectiveness of existing foundry solution annealing procedures for producing cast DSS without intermetallic phases were implemented. In the ASTM E562 study, 5 samples were extracted from various cast austenitic and DSS in order to have varying amounts of ferrite. Each sample was metallographically prepared by UT and sent to each of 8 participants for volume fraction of ferrite measurements. Volume fraction of ferrite was measured using manual point count per ASTM E562. FN was measured from the Feritescope{reg_sign} and converted to volume fraction of ferrite. Results indicate that ASTM E562 is applicable to DSS and the results have excellent lab-to-lab reproducibility. Also, volume fraction of ferrite conversions from the FN measured by the Feritescope{reg_sign} were similar to volume fraction of ferrite measured per ASTM E562. In the ASTM A923 applicability to cast DSS study, 8 different heat treatments were performed on 3 lots of ASTM A890-4A (CD3MN) castings and 1 lot of 2205 wrought DSS. The heat treatments were selected to produce a wide range of cooling rates and hold times in order to study the suitability of ASTM A923 to the response of varying amounts on intermetallic phases [117]. The test parameters were identical to those used to develop ASTM A923 for wrought DSS. Charpy V-notch impact samples were extracted from the

  11. Final Report, Volume 2, The Development of Qualification Standards for Cast Duplex Stainless Steel

    Energy Technology Data Exchange (ETDEWEB)

    Russell, Steven, W.; Lundin, Carl, W.

    2005-09-30

    The scope of testing cast Duplex Stainless Steel (DSS) required testing to several ASTM specifications, while formulating and conducting industry round robin tests to verify and study the reproducibility of the results. ASTM E562 (Standard Test Method for Determining Volume Fraction by Systematic manual Point Count) and ASTM A923 (Standard Test Methods for Detecting Detrimental Intermetallic Phase in Wrought Duplex Austenitic/Ferritic Stainless Steels) were the specifications utilized in conducting this work. An ASTM E562 industry round robin, ASTM A923 applicability study, ASTM A923 industry round robin, and an ASTM A923 study of the effectiveness of existing foundry solution annealing procedures for producing cast DSS without intermetallic phases were implemented. In the ASTM E562 study, 5 samples were extracted from various cast austenitic and DSS in order to have varying amounts of ferrite. Each sample was metallographically prepared by UT and sent to each of 8 participants for volume fraction of ferrite measurements. Volume fraction of ferrite was measured using manual point count per ASTM E562. FN was measured from the Feritescope® and converted to volume fraction of ferrite. Results indicate that ASTM E562 is applicable to DSS and the results have excellent lab-to-lab reproducibility. Also, volume fraction of ferrite conversions from the FN measured by the Feritescope® were similar to volume fraction of ferrite measured per ASTM E562. In the ASTM A923 applicability to cast DSS study, 8 different heat treatments were performed on 3 lots of ASTM A890-4A (CD3MN) castings and 1 lot of 2205 wrought DSS. The heat treatments were selected to produce a wide range of cooling rates and hold times in order to study the suitability of ASTM A923 to the response of varying amounts on intermetallic phases [117]. The test parameters were identical to those used to develop ASTM A923 for wrought DSS. Charpy V-notch impact samples were extracted from the castings and wrought

  12. Standard Guide for Preparing Waste Management Plans for Decommissioning Nuclear Facilities

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This guide addresses the development of waste management plans for potential waste streams resulting from decommissioning activities at nuclear facilities, including identifying, categorizing, and handling the waste from generation to final disposal. 1.2 This guide is applicable to potential waste streams anticipated from decommissioning activities of nuclear facilities whose operations were governed by the Nuclear Regulatory Commission (NRC) or Agreement State license, under Department of Energy (DOE) Orders, or Department of Defense (DoD) regulations. 1.3 This guide provides a description of the key elements of waste management plans that if followed will successfully allow for the characterization, packaging, transportation, and off-site treatment or disposal, or both, of conventional, hazardous, and radioactive waste streams. 1.4 This guide does not address the on-site treatment, long term storage, or on-site disposal of these potential waste streams. 1.5 This standard does not purport to address ...

  13. 46 CFR 164.015-1 - Applicable specifications and standards.

    Science.gov (United States)

    2010-10-01

    ..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL MATERIALS Plastic Foam, Unicellular, Buoyant, Sheet... following specification and standard, of the issue in effect on the date the plastic foam material is...) ASTM D4986-98, Standard Test Method for Horizontal Burning Characteristics of Cellular Polymeric...

  14. Guide for dosimetry for sterile insect release programs. 2. ed.

    International Nuclear Information System (INIS)

    2004-01-01

    This guide outlines dosimetric procedures to be followed for the radiation sterilization of live insects for use in pest management programs. The primary use of irradiated, reproductively sterile insects is in the Sterile Insect Technique, where large numbers of sterile insects are released into the field to mate with and thus control pest populations of the same species. A secondary use of sterile insects is as benign hosts for rearing insect parasitoids. The procedures outlined in this guide will help ensure that insects processed with ionizing radiation from gamma, electron, or X-ray sources receive absorbed doses within a predetermined range. Information on effective dose ranges for specific applications of insect sterilization, or on methodology for determining effective dose ranges, is not within the scope of this guide. Note: Dosimetry is only one component of a total quality control program to ensure that irradiated insects are adequately sterilized and sufficiently competitive or otherwise suitable for their intended purpose. This guide covers dosimetry in the irradiation of insects for these types of irradiators: self-contained dry-storage 137 Cs or 60 Co irradiators, large-scale gamma irradiators, and electron accelerators. Additional, detailed information on dosimetric procedures to be followed in installation qualification, operational qualification, performance qualification, and routine product processing can be found in ISO/ASTM Practices 51608 (X-ray [bremsstrahlung] facilities), 51649 (electron beam facilities), 51702 (large-scale gamma facilities), and ASTM Practice E 2116 (self-contained dry-storage gamma facilities). The absorbed dose for insect sterilization is typically within the range of 20 Gy to 600 Gy

  15. The Trends and Prospects of Health Information Standards : Standardization Analysis and Suggestions

    International Nuclear Information System (INIS)

    Kim, Chang Soo

    2008-01-01

    Ubiquitous health care system, which is one of the developing solution technologies of IT, BT and NT, could give us new medical environments in future. Implementing health information systems can be complex, expensive and frustrating. Healthcare professionals seeking to acquire or upgrade systems do not have a convenient, reliable way of specifying a level of adherence to communication standards sufficient to achieve truly efficient interoperability. Great progress has been made in establishing such standards-DICOM, IHE and HL7, notably, are now highly advanced. IHE has defined a common framework to deliver the basic interoperability needed for local and regional health information networks. It has developed a foundational set of standards-based integration profiles for information exchange with three interrelated efforts. HL7 is one of several ANSI-accredited Standards Developing Organizations operating in the healthcare arena. Most SDOs produce standards (protocols) for a particular healthcare domain such as pharmacy, medical devices, imaging or insurance transactions. HL7's domain is clinical and administrative data. HL7 is an international community of healthcare subject matter experts and information scientists collaborating to create standards for the exchange, management and integration of electronic healthcare information. The ASTM specification for Continuity of Care Record was developed by subcommittee E31.28 on electronic health records, which includes clinicians, provider institutions, administrators, patient advocates, vendors, and health industry. In this paper, there are suggestions that provide a test bed, demonstration and specification of how standards such a IHE, HL7, ASTM can be used to provide an integrated environment.

  16. The Trends and Prospects of Health Information Standards : Standardization Analysis and Suggestions

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Soo [Dept. of Radiological Science, College of Health Science, Catholic University of Pusan, Pusan (Korea, Republic of)

    2008-03-15

    Ubiquitous health care system, which is one of the developing solution technologies of IT, BT and NT, could give us new medical environments in future. Implementing health information systems can be complex, expensive and frustrating. Healthcare professionals seeking to acquire or upgrade systems do not have a convenient, reliable way of specifying a level of adherence to communication standards sufficient to achieve truly efficient interoperability. Great progress has been made in establishing such standards-DICOM, IHE and HL7, notably, are now highly advanced. IHE has defined a common framework to deliver the basic interoperability needed for local and regional health information networks. It has developed a foundational set of standards-based integration profiles for information exchange with three interrelated efforts. HL7 is one of several ANSI-accredited Standards Developing Organizations operating in the healthcare arena. Most SDOs produce standards (protocols) for a particular healthcare domain such as pharmacy, medical devices, imaging or insurance transactions. HL7's domain is clinical and administrative data. HL7 is an international community of healthcare subject matter experts and information scientists collaborating to create standards for the exchange, management and integration of electronic healthcare information. The ASTM specification for Continuity of Care Record was developed by subcommittee E31.28 on electronic health records, which includes clinicians, provider institutions, administrators, patient advocates, vendors, and health industry. In this paper, there are suggestions that provide a test bed, demonstration and specification of how standards such a IHE, HL7, ASTM can be used to provide an integrated environment.

  17. Combating Wear of ASTM A36 Steel by Surface Modification Using Thermally Sprayed Cermet Coatings

    OpenAIRE

    Shibe, Vineet; Chawla, Vikas

    2016-01-01

    Thermal spray coatings can be applied economically on machine parts to enhance their requisite surface properties like wear, corrosion, erosion resistance, and so forth. Detonation gun (D-Gun) thermal spray coatings can be applied on the surface of carbon steels to improve their wear resistance. In the present study, alloy powder cermet coatings WC-12% Co and Cr3C2-25% NiCr have been deposited on ASTM A36 steel with D-Gun thermal spray technique. Sliding wear behavior of uncoated ASTM A36 ste...

  18. 76 FR 47555 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line and Pressure Pipe From Japan...

    Science.gov (United States)

    2011-08-05

    ... Engineers (``ASME'') code stress levels. Alloy pipes made to ASTM A-335 standard must be used if temperatures and stress levels exceed those allowed for ASTM A-106. Seamless pressure pipes sold in the United..., or pressure pipe applications. B. Finished and unfinished oil country tubular goods (``OCTG''), if...

  19. Experimental and numerical study of a modified ASTM C633 adhesion test for strongly-bonded coatings

    Energy Technology Data Exchange (ETDEWEB)

    Bernardie, Raphaëlle; Berkouch, Reda; Valette, Stéphane; Absi, Joseph; Lefort, Pierre [University of Limoges, Limoges Cedex (France)

    2017-07-15

    When coatings are strongly bonded to their substrates it is often difficult to measure the adhesion values. The proposed method, which is suggested naming “silver print test”, consists in covering the central part of the samples with a thin layer of silver paint, before coating. The process used for testing this new method was the Air plasma spraying (APS), and the materials used were alumina coatings on C35 steel substrates, previously pre-oxidized in CO{sub 2}. The silver painted area was composed of small grains that did not oxidize but that significantly sintered during the APS process. The silver layer reduced the surface where the coating was linked to the substrate, which allowed its debonding, using the classical adhesion test ASTM C633-13, while the direct use of this test (without silver painting) led to ruptures inside the glue used in this test. The numerical modelling, based on the finite element method with the ABAQUS software, provided results in good agreement with the experimental measurements. This concordance validated the used method and allowed accessing to the values of adherence when the experimental test ASTM C633-13 failed, because of ruptures in the glue. After standardization, the “silver print test” might be used for other kinds of deposition methods, such as PVD, CVD, PECVD.

  20. Evaluation of a standard shade guide for color change after disinfection.

    Science.gov (United States)

    Pohjola, Randall M; Hackman, Steven T; Browning, William D

    2007-09-01

    To determine if surface disinfectants cause a change in the shade perception of a standard Classic Vitapan shade guide. Consistency in shade selection for dental restorations involves many factors, and one of the most important is the shade tabs used in the selection process. Ten shade tabs each of shades B2, D2, C1, and A3.5 were selected from the Classic Vitapan shade guide (Vident). All tabs were measured with the EasyShade shade device (Vident) at baseline. Three tabs of each shade were set aside as controls. The other 7 tabs of each shade were treated with the surface disinfectant Cavicide (Metrex Research) for 480 cycles to simulate a year's usage. After each 480 cycles, all the tabs were again measured with the EasyShade. This process was repeated to simulate 2 and 3 years of use. The data were analyzed to calculate the delta E 2000 for any change. A statistically significant increase was observed in the value (L*) and chroma (C*) after 2 and 3 years of simulated treatments. These changes were not perceptible to the clinician. The authors suggest that 1 standard shade guide be set aside to compare against those in clinical use to determine when they should be replaced.

  1. New ASTM Standards for Nondestructive Testing of Aerospace Composites

    Science.gov (United States)

    Waller, Jess M.; Saulsberry, Regor L.

    2010-01-01

    Problem: Lack of consensus standards containing procedural detail for NDE of polymer matrix composite materials: I. Flat panel composites. II. Composite components with more complex geometries a) Pressure vessels: 1) composite overwrapped pressure vessels (COPVs). 2) composite pressure vessels (CPVs). III. Sandwich core constructions. Metal and brittle matrix composites are a possible subject of future effort.

  2. Chronic ankle pain and fibrosis successfully treated with a new noninvasive augmented soft tissue mobilization technique (ASTM): a case report.

    Science.gov (United States)

    Melham, T J; Sevier, T L; Malnofski, M J; Wilson, J K; Helfst, R H

    1998-06-01

    This clinical case report demonstrates the clinical effectiveness of a new form of soft tissue mobilization in the treatment of excessive connective tissue fibrosis (scar tissue) around an athlete's injured ankle. The scar tissue was causing the athlete to have pain with activity, pain on palpation of the ankle, decreased range of motion, and loss of function. Surgery and several months of conventional physical therapy failed to alleviate the athlete's symptoms. As a final resort, augmented soft tissue mobilization (ASTM) was administered. ASTM is an alternative nonsurgical treatment modality that is being researched at Performance Dynamics (Muncip, IN). ASTM is a process that uses ergonomically designed instruments that assist therapists in the rapid localization and effective treatment of areas exhibiting excessive soft tissue fibrosis. This is followed by a stretching and strengthening program. Upon the completion of 6 wk of ASTM therapy, the athlete had no pain and had regained full range of motion and function. This case report is an example of how a noninvasive augmented form of soft tissue mobilization (ASTM) demonstrated impressive clinical results in treating a condition caused by connective tissue fibrosis.

  3. JBK-75 microstructure specification recommendation

    International Nuclear Information System (INIS)

    Brewer, A.W.

    1977-01-01

    Since the ASTM-E-45 standard for microcleanliness is not applicable to superalloys like JBK-75 stainless steel (Modified A-286), Rocky Flats should adopt the Ladish microcleanliness standard (APML Cleanliness Classification of High Temperature Alloys Chart, 1971), as a guide for setting material acceptance specifications for JBK-75. Inclusion ratings of S-2, N-2, C-2, and M-2 should be acceptable. The microstructure should have a grain size of 5 or finer, but not smaller than 9, and microsegregation (banding) should be kept to a minimum

  4. Guide: Monitoring Programme for unannounced inspections undertaken against the National Standards for the Prevention and Control of Healthcare Associated Infections

    OpenAIRE

    2014-01-01

    This is a guide to the Health Information and Quality Authority?s (the Authority) programme of monitoring service providers? compliance with the National Standards for the Prevention and Control of Healthcare Associated Infections (referred to in this guide as the Infection, Prevention and Control Standards). This guide explains the approach that the Authority takes when monitoring the compliance of service providers ? including hospitals ? with the Infection, Prevention and Control Standards...

  5. Standard Guide for Conducting Corrosion Tests in Field Applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This guide covers procedures for conducting corrosion tests in plant equipment or systems under operating conditions to evaluate the corrosion resistance of engineering materials. It does not cover electrochemical methods for determining corrosion rates. 1.1.1 While intended primarily for immersion tests, general guidelines provided can be applicable for exposure of test specimens in plant atmospheres, provided that placement and orientation of the test specimens is non-restrictive to air circulation. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See also 10.4.2.

  6. 77 FR 27428 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe (Over 41/2

    Science.gov (United States)

    2012-05-10

    ... (``ASME'') code stress levels. Alloy pipes made to ASTM A-335 standard must be used if temperatures and stress levels exceed those allowed for ASTM A-106. Seamless pressure pipes sold in the United States are..., or pressure pipe applications. B. Finished and unfinished oil country tubular goods (``OCTG''), if...

  7. 76 FR 66688 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe (Over 41/2

    Science.gov (United States)

    2011-10-27

    ... (``ASME'') code stress levels. Alloy pipes made to ASTM A-335 standard must be used if temperatures and stress levels exceed those allowed for ASTM A-106. Seamless pressure pipes sold in the United States are..., or pressure pipe applications. B. Finished and unfinished oil country tubular goods (``OCTG''), if...

  8. Comparative field permeability measurement of permeable pavements using ASTM C1701 and NCAT permeameter methods.

    Science.gov (United States)

    Li, Hui; Kayhanian, Masoud; Harvey, John T

    2013-03-30

    Fully permeable pavement is gradually gaining support as an alternative best management practice (BMP) for stormwater runoff management. As the use of these pavements increases, a definitive test method is needed to measure hydraulic performance and to evaluate clogging, both for performance studies and for assessment of permeability for construction quality assurance and maintenance needs assessment. Two of the most commonly used permeability measurement tests for porous asphalt and pervious concrete are the National Center for Asphalt Technology (NCAT) permeameter and ASTM C1701, respectively. This study was undertaken to compare measured values for both methods in the field on a variety of permeable pavements used in current practice. The field measurements were performed using six experimental section designs with different permeable pavement surface types including pervious concrete, porous asphalt and permeable interlocking concrete pavers. Multiple measurements were performed at five locations on each pavement test section. The results showed that: (i) silicone gel is a superior sealing material to prevent water leakage compared with conventional plumbing putty; (ii) both methods (NCAT and ASTM) can effectively be used to measure the permeability of all pavement types and the surface material type will not impact the measurement precision; (iii) the permeability values measured with the ASTM method were 50-90% (75% on average) lower than those measured with the NCAT method; (iv) the larger permeameter cylinder diameter used in the ASTM method improved the reliability and reduced the variability of the measured permeability. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Evaluating the Sporicidal Activity of Disinfectants against Clostridium difficile and Bacillus amyloliquefaciens Spores by Using the Improved Methods Based on ASTM E2197-11.

    Science.gov (United States)

    Uwamahoro, Marie Christine; Massicotte, Richard; Hurtubise, Yves; Gagné-Bourque, François; Mafu, Akier Assanta; Yahia, L'Hocine

    2018-01-01

    Spore-forming pathogenic bacteria, such as Clostridium difficile , are associated with nosocomial infection, leading to the increased use of sporicidal disinfectants, which impacts socioeconomic costs. However, C. difficile can be prevented using microorganisms such as Bacillus amyloliquefaciens , a prophylactic agent that has been proven to be effective against it in recent tests or it can be controlled by sporicidal disinfectants. These disinfectants against spores should be evaluated according to a known and recommended standard. Unfortunately, some newly manufactured disinfectants like Bioxy products have not yet been tested. ASTM E2197-11 is a standard test that uses stainless steel disks (1 cm in diameter) as carriers, and the performance of the test formulation is calculated by comparing the number of viable test organisms to that on the control carriers. Surface tests are preferable for evaluating disinfectants with sporicidal effects on hard surfaces. This study applies improved methods, based on the ASTM E2197-11 standard, for evaluating and comparing the sporicidal efficacies of several disinfectants against spores of C. difficile and B. amyloliquefaciens , which are used as the test organisms. With the improved method, all spores were recovered through vortexing and membrane filtration. The results show that chlorine-based products are effective in 5 min and Bioxy products at 5% w/v are effective in 10 min. Although Bioxy products may take longer to prove their effectiveness, their non-harmful effects to hospital surfaces and people have been well established in the literature.

  10. Recent development in the ASME O and M committee codes, standards, and guides

    International Nuclear Information System (INIS)

    Rowley, C.W.

    1999-01-01

    The ASME O and M Committee continues to expand and update its code, standards, and guides as contained in the ASME OM Code and the ASME OM Standards/Guides. This paper will describe recent changes to these two ASME documents, including technical inquiries, code cases, and the major reformat of the ASME OM Code 1998 Edition. Also two new Parts to the ASME OM S/G will be discussed: OM Part 23 and OM Part 24, which are close to being initially published. A third new Part to the ASME OM S/G has been authorized and has recently started to get organized: Part 26, 'Thermal Calibration of RTDs'. In addition this paper will describe the future plans for these two documents as provided in the O and M Committee Strategic Plan. (author)

  11. Mechanical properties of ASTM A508 Class 4 steel used in the LWBR closure head and support flange (LWBR Development Program)

    International Nuclear Information System (INIS)

    Allen, R.M.; Hall, J.F.

    1978-07-01

    The LWBR closure head and support flange are manufactured from forgings of ASTM A508 Class 4 steel rather than the ASTM A508 Class 2 forging material more commonly used in reactor vessels and closure heads. Forgings involved were approximately 300,000 pounds and 46,000 pounds. The extensive material test program conducted on ASTM A508 Class 4 LWBR forgings is described. The results of the tests confirm that the A508 Class 4 material used for the LWBR forgings has been quite good through thickness, fracture toughness, and strength properties and fully meet all specified requirements

  12. Standard guide for precision electroformed wet sieve analysis of nonplastic ceramic powders

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This guide covers the determination of the particle size distribution of pulverized alumina and quartz for particle sizes from 45 to 5 μm by wet sieving. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.2.1 The only exception is in the Section 5, Apparatus, 5.1 where there is no relevant SI equivalent. 1.3 This standard does not purport to address the safety concerns associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  13. 78 FR 57818 - Commission Participation and Commission Employee Involvement in Voluntary Standards Activities

    Science.gov (United States)

    2013-09-20

    ... docket number for this rulemaking. All comments received may be posted without change, including any... found in in such locations as homes, schools, and recreational areas. Voluntary standards activity is an... handled primarily by three standards development/coordinating organizations: ASTM International...

  14. Standard Guide for Irradiation of Fresh Agricultural Produce as a Phytosanitary Treatment

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This guide provides procedures for the radiation processing of fresh agricultural produce, for example, fruits, vegetables, and cut flowers, as a phytosanitary treatment. This guide is directed primarily toward the treatment needed to control regulated pests commonly associated with fresh agricultural produce. 1.2 The typical absorbed dose range used for phytosanitary treatments is between 150 gray (Gy) and 600 gray (Gy). The practical minimum or maximum dose of a treatment may be higher or lower than this range, depending on the type of pest to be controlled and the radiation tolerance of a particular type of fruit. If the minimum effective dose necessary to achieve the desired phytosanitary effect is greater than the radiation tolerance of the produce, then irradiation is not an appropriate treatment (see ). This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and hea...

  15. New standards for digital radiography and qualification of detectors; Neue Standards zur Digitalen Radiographie und Qualifizierung von Detektoren

    Energy Technology Data Exchange (ETDEWEB)

    Ewert, Uwe; Zscherpel, Uwe [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany)

    2017-08-01

    The contribution describes the most important standards for radiographic examinations that are revised in different committees. Information is given on new requirements esp. on revised parameters that have to be considered in practical testing procedures and classification. Actually for the revision of ISO 17636-1/2 in 2018 user questions are collected concerning weld seam testing. The DIN 25435 standards for weld seam testing in nuclear technology have been translated into English. Revisions of ASTM standards have to be considered in the actual EN and ISO standards. Since several years the International Institute of Welding (IIW) is also revising the international standards.

  16. The Status of silicosis in the world: Feedback on the ASTM Silica Symposium

    CSIR Research Space (South Africa)

    Pretorius, CJ

    2013-06-01

    Full Text Available The second ASTM Silica Symposium was held in Oct 2012 where speakers reported on the status of silicosis in their respective countries. Speakers reported on findings of research that they carried out on sampling equipment and analytical techniques...

  17. ASTM clustering for improving coal analysis by near-infrared spectroscopy.

    Science.gov (United States)

    Andrés, J M; Bona, M T

    2006-11-15

    Multivariate analysis techniques have been applied to near-infrared (NIR) spectra coals to investigate the relationship between nine coal properties (moisture (%), ash (%), volatile matter (%), fixed carbon (%), heating value (kcal/kg), carbon (%), hydrogen (%), nitrogen (%) and sulphur (%)) and the corresponding predictor variables. In this work, a whole set of coal samples was grouped into six more homogeneous clusters following the ASTM reference method for classification prior to the application of calibration methods to each coal set. The results obtained showed a considerable improvement of the error determination compared with the calibration for the whole sample set. For some groups, the established calibrations approached the quality required by the ASTM/ISO norms for laboratory analysis. To predict property values for a new coal sample it is necessary the assignation of that sample to its respective group. Thus, the discrimination and classification ability of coal samples by Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS) in the NIR range was also studied by applying Soft Independent Modelling of Class Analogy (SIMCA) and Linear Discriminant Analysis (LDA) techniques. Modelling of the groups by SIMCA led to overlapping models that cannot discriminate for unique classification. On the other hand, the application of Linear Discriminant Analysis improved the classification of the samples but not enough to be satisfactory for every group considered.

  18. Standard format and content guide for financial assurance mechanisms required for decommissioning under 10 CFR parts 30, 40, 70, and 72

    International Nuclear Information System (INIS)

    1989-08-01

    The Standard Format and Content Guide for Financial Assurance Mechanisms Required for Decommissioning under 10 CFR Parts 30, 40, 70, and 72, discusses the information to be provided in a license application and established a uniform format for presenting the information required to meet the decommissioning licensing requirements. The use of the Standard Format and Content Guide will (1) help ensure that the license application contains the information required by the regulations, (2) aid the applicant in ensuring that the information is complete, (3) help persons reading the Standard Format and Content Guide to locate information, and (4) contribute to shortening the time required for the review process. The Standard Format and Content Guide ensures that the information required to perform the review is provided, and in a useable format

  19. 77 FR 25721 - Small Entity Compliance Guide: Bottled Water: Quality Standard: Establishing an Allowable Level...

    Science.gov (United States)

    2012-05-01

    ...] Small Entity Compliance Guide: Bottled Water: Quality Standard: Establishing an Allowable Level for di(2... ``Bottled Water: Quality Standard: Establishing an Allowable Level for di(2- ethylhexyl)phthalate--Small... an allowable level for di(2- ethylhexyl)phthalate (DEHP). This final rule is effective April 16, 2012...

  20. 78 FR 35085 - Consensus Standards, Light-Sport Aircraft

    Science.gov (United States)

    2013-06-11

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Consensus Standards, Light-Sport... to the provisions of the Sport Pilot and Light-Sport Aircraft rule issued July 16, 2004, and effective September 1, 2004. ASTM International Committee F37 on Light Sport Aircraft developed the new and...

  1. 77 FR 24251 - Consensus Standards, Light-Sport Aircraft

    Science.gov (United States)

    2012-04-23

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Consensus Standards, Light-Sport... relating to the provisions of the Sport Pilot and Light-Sport Aircraft rule issued July 16, 2004, and effective September 1, 2004. ASTM International Committee F37 on Light Sport Aircraft developed the new and...

  2. Standard guide for the determination of technetium-99 in Soil

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This guide is intended to serve as a reference for laboratories wishing to perform Tc-99 analyses in soil. Several options are given for selection of a tracer and for the method of extracting the Tc from the soil matrix. Separation of Tc from the sample matrix is performed using an extraction chromatography resin. Options are then given for the determination of the Tc-99 activity in the original sample. It is up to the user to determine which options are appropriate for use, and to generate acceptance data to support the chosen procedure. 1.2 Due to the various extraction methods available, various tracers used, variable detection methods used, and lack of certified reference materials for Tc-99 in soil, there is insufficient data to support a single method written as a standard method. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

  3. Standard Guide for Evaluating Disposal Options for Concrete from Nuclear Facility Decommissioning

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This standard guide defines the process for developing a strategy for dispositioning concrete from nuclear facility decommissioning. It outlines a 10-step method to evaluate disposal options for radioactively contaminated concrete. One of the steps is to complete a detailed analysis of the cost and dose to nonradiation workers (the public); the methodology and supporting data to perform this analysis are detailed in the appendices. The resulting data can be used to balance dose and cost and select the best disposal option. These data, which establish a technical basis to apply to release the concrete, can be used in several ways: (1) to show that the release meets existing release criteria, (2) to establish a basis to request release of the concrete on a case-by-case basis, (3) to develop a basis for establishing release criteria where none exists. 1.2 This standard guide is based on the “Protocol for Development of Authorized Release Limits for Concrete at U.S. Department of Energy Sites,” (1) from ...

  4. Standard guide for hot cell specialized support equipment and tools

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 Intent: 1.1.1 This guide presents practices and guidelines for the design and implementation of equipment and tools to assist assembly, disassembly, alignment, fastening, maintenance, or general handling of equipment in a hot cell. Operating in a remote hot cell environment significantly increases the difficulty and time required to perform a task compared to completing a similar task directly by hand. Successful specialized support equipment and tools minimize the required effort, reduce risks, and increase operating efficiencies. 1.2 Applicability: 1.2.1 This guide may apply to the design of specialized support equipment and tools anywhere it is remotely operated, maintained, and viewed through shielding windows or by other remote viewing systems. 1.2.2 Consideration should be given to the need for specialized support equipment and tools early in the design process. 1.2.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conv...

  5. Safety critical systems handbook a straightforward guide to functional safety : IEC 61508 (2010 edition) and related standards

    CERN Document Server

    Smith, David J

    2010-01-01

    Electrical, electronic and programmable electronic systems increasingly carry out safety functions to guard workers and the public against injury or death and the environment against pollution. The international functional safety standard IEC 61508 was revised in 2010, and this is the first comprehensive guide available to the revised standard. As functional safety is applicable to many industries, this book will have a wide readership beyond the chemical and process sector, including oil and gas, power generation, nuclear, aircraft, and automotive industries, plus project, instrumentation, design, and control engineers. * The only comprehensive guide to IEC 61508, updated to cover the 2010 amendments, that will ensure engineers are compliant with the latest process safety systems design and operation standards* Helps readers understand the process required to apply safety critical systems standards* Real-world approach helps users to interpret the standard, with case studies and best practice design examples...

  6. Standard practice for preparation and use of direct tension stress-corrosion test specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This practice covers procedures for designing, preparing, and using ASTM standard tension test specimens for investigating susceptibility to stress-corrosion cracking. Axially loaded specimens may be stressed quantitatively with equipment for application of either a constant load, constant strain, or with a continuously increasing strain. 1.2 Tension test specimens are adaptable for testing a wide variety of product forms as well as parts joined by welding, riveting, or various other methods. 1.3 The exposure of specimens in a corrosive environment is treated only briefly because other standards are being prepared to deal with this aspect. Meanwhile, the investigator is referred to Practices G35, G36, G37, and G44, and to ASTM Special Technical Publication 425 (1).

  7. Handbook on Life Cycle Assessment. Operational Guide to the ISO Standards

    Energy Technology Data Exchange (ETDEWEB)

    Guinee, J.B. [Centre of Environmental Studies, Leiden University, Leiden (Netherlands)

    2002-04-01

    In 1992 the Centre of Environmental Science (CML) at Leiden University, The Netherlands, published a Guide on Environmental Life Cycle Assessment (LCA) methodology, setting the standard for a long time. Since then LCA methodology has progressed enormously and the International Organization for Standardization (ISO) has published a series of Standards on LCA. These developments have now been incorporated into a new Handbook on LCA authored by CML in cooperation with a number of other important institutes in the area of LCA. The general aim of this Handbook on LCA is to provide a stepwise 'cookbook' with operational guidelines for conducting an LCA study step-by-step, justified by a scientific background document, based on the ISO Standards for LCA. The different ISO elements and requirements are made operational to the 'best available practice' for each step. CML is strongly involved in the development of a standard methodology to determine environmental impacts of products, i.e., LCA. This is done within international fora such as the Society for Environmental Toxicology and Chemistry (SETAC), the International Organization for Standardization (ISO), and the United Nations Environmental Programme (UNEP)

  8. Autogenous shrinkage of Ducorit S5R ASTM C 1698-09 test method

    DEFF Research Database (Denmark)

    Damkilde, Lars

    The report deals with experimental measurement of autogenous shrinkage of Ducorit S5R according to the test method ASTM C 1698-09. This test method measures the bulk strain of a sealed cementitious specimen, at constant temperature and not subjected to external forces, from the time of final...

  9. Standard guide for corrosion-related failure analysis

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This guide covers key issues to be considered when examining metallic failures when corrosion is suspected as either a major or minor causative factor. 1.2 Corrosion-related failures could include one or more of the following: change in surface appearance (for example, tarnish, rust, color change), pin hole leak, catastrophic structural failure (for example, collapse, explosive rupture, implosive rupture, cracking), weld failure, loss of electrical continuity, and loss of functionality (for example, seizure, galling, spalling, swelling). 1.3 Issues covered include overall failure site conditions, operating conditions at the time of failure, history of equipment and its operation, corrosion product sampling, environmental sampling, metallurgical and electrochemical factors, morphology (mode) or failure, and by considering the preceding, deducing the cause(s) of corrosion failure. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibili...

  10. Standardized Cost Structure for the Environmental Industry

    International Nuclear Information System (INIS)

    Skokan, B.; Melamed, D.; Guevara, K.; Mallick, P.; Bierman, G.; Marshall, H.E.

    2006-01-01

    The underlying key to developing successful estimates, tracking project costs, and utilizing historical project cost information is the development of standardized and well-defined hierarchical listing of cost categories. Committees within the U.S. Federal agencies have pioneered efforts toward developing the Environmental Cost Element Structure (ECES), which is key in achieving these goals. The ECES was developed using an iterative process with input from federal agencies and industry. Experts from several disciplines participated including engineers, cost estimators, project/program managers, and contract personnel. The ECES benefits from an intense analytical effort, the knowledge gained from the maturation of the environmental industry, and incorporation of past user's experiences. Building upon this foundation, the E06 committee of the ASTM International has now fully developed and published a standard (ASTM 2150-04) that provides standardized cost categories with complete cost category definitions. This standard affords environmental and nuclear D and D project managers the opportunity to have a well defined hierarchical listing of their estimates and actual costs, readily adapted to performing summations and roll-ups, supported by a multi-level dictionary specifically defining the content of the cost elements as well as the summations. Owing to the dynamic nature of the environmental technologies, efforts need to be made to continue to update this standard by adding new technologies and methods as they are developed and employed in the field. Lastly, the Environmental Cost Element Structure that is embodied in this standard also presents opportunities to develop historical cost databases and comprehensive life cycle cost estimates and standardized cost estimating tools. (authors)

  11. Wavefront-guided versus standard laser in situ keratomileusis to correct low to moderate myopia.

    NARCIS (Netherlands)

    Nuijts, R.M.; Nabar, V.A.; Hament, W.J.; Eggink, F.A.G.J.

    2002-01-01

    To evaluate the 6-month refractive outcomes of wavefront-guided laser in situ keratomileusis (LASIK) (Zyoptix, Bausch & Lomb) versus standard LASIK (PlanoScan, Bausch & Lomb).Department of Ophthalmology, University Hospital Maastricht, Maastricht, The Netherlands.In a prospective randomized study,

  12. Guide to nondestructive assay standards: Preparation criteria, availability, and practical considerations

    International Nuclear Information System (INIS)

    Hsue, S.T.; Stewart, J.E.; Sampson, T.E.; Butler, G.W.; Rudy, C.R.; Rinard, P.M.

    1997-10-01

    For certification and measurement control, nondestructive assay (NDA) instruments and methods used for verification measurements of special nuclear materials (SNMs) require calibrations based on certified reference materials (CRMs), or working reference materials (WRMs), traceable to the national system of measurements, and adequately characteristic of the unknowns. The Department of Energy Office of Safeguards and Security is sponsoring production of a comprehensive guide to preparation of NDA standards. The scope of the report includes preparation criteria, current availability of CRMs and WRMs, practical considerations for preparation and characterization, and an extensive bibliography. In preparing the report, based primarily on experience at Los Alamos, they have found that standards preparation is highly dependent on the particular NDA method being applied. They therefore include sections that contain information specific to commonly used neutron and gamma-ray NDA techniques. They also present approaches that are alternatives to, or minimize requirements for physical standards

  13. Fractionation and characterization of particles simulating wear of total joint replacement (TJR) following ASTM standards.

    Science.gov (United States)

    Saha, Subrata; Musib, Mrinal

    2011-01-01

    Reactions of bone cells to orthopedic wear debris produced by the articulating motion of total joint replacements (TJRs) are largely responsible for the long-term failure of such replacements. Metal and polyethylene (PE) wear particles isolated from fluids from total joint simulators, as well as particles that are fabricated by other methods, are widely used to study such in vitro cellular response. Prior investigations have revealed that cellular response to wear debris depends on the size, shape, and dose of the particles. Hence, to have a better understanding of the wear-mediated osteolytic process it is important that these particles are well characterized and clinically relevant, both qualitatively, and quantitatively. In this study we have fractionated both ultra-high molecular weight polyethylene (UHMWPE) and Ti particles, into micron (1.0-10.0 μm), submicron (0.2-1.0 μm), and nanoparticle (0.01-0.2 μm) fractions, and characterized them based on the following size-shape descriptors as put forth in ASTM F1877: i) equivalent circle diameter (ECD), ii) aspect ratio (AR), iii) elongation (E), iv) roundness (R), and v) form factor (FF). The mean (± SD) ECDs (in μm) for micron, submicron, and nanoparticles of UHMWPE were 1.652 ± 0.553, 0.270 ± 0.180, and 0.061 ± 0.035, respectively, and for Ti were 1.894 ± 0.667, 0.278 ± 0.180, and 0.055 ± 0.029, respectively. The values for other descriptors were similar (no statistically significant difference). The nanofraction particles were found to be more sphere-like (higher R and FF values, and lower E and AR values) as compared to larger particles. Future experiments will involve use of these well characterized particles for in vitro studies.

  14. iCloud standard guide

    CERN Document Server

    Alfi, Fauzan

    2013-01-01

    An easy-to-use guide, filled with tutorials that will teach you how to set up and use iCloud, and profit from all of its marvellous features.This book is for anyone with basic knowledge of computers and mobile operations. Prior knowledge of cloud computing or iCloud is not expected.

  15. 77 FR 73354 - Safety Standard for Hand-Held Infant Carriers

    Science.gov (United States)

    2012-12-10

    .... Edwards, Project Manager, Directorate for Engineering Sciences, U.S. Consumer Product Safety Commission, 5..., allergic reactions and near- choking episodes are the most common injuries reported in the remaining 58... modification of the ASTM standard to address the requirements for flammability, surface chemicals, cords...

  16. NAGC Pre-K-Grade 12 Gifted Education Programming Standards: A Guide to Planning and Implementing High-Quality Services

    Science.gov (United States)

    Johnsen, Susan K., Ed.

    2012-01-01

    The new Pre-K-Grade 12 Gifted Education Programming Standards should be part of every school district's repertoire of standards to ensure that the learning needs of advanced students are being met. "NAGC Pre-K-Grade 12 Gifted Education Programming Standards: A Guide to Planning and Implementing High-Quality Services" details six standards that…

  17. SOFG: Standards requirements

    International Nuclear Information System (INIS)

    Gerganov, T.; Grigorov, S.; Kozhukharov, V.; Brashkova, N.

    2005-01-01

    It is well-known that Solid Oxide Fuel Cells will have industrial application in the nearest future. In this context, the problem of SOFC materials and SOFC systems standardization is of high level of priority. In the present study the attention is focused on the methods for physical and chemical characterization of the materials for SOFC components fabrication and about requirements on single SOFC cells tests. The status of the CEN, ISO, ASTM (ANSI, ASSN) and JIS class of standards has been verified. Standards regarding the test methods for physical-chemical characterization of vitreous materials (as sealing SOFC component), ceramic materials (as electrodes and electrolyte components, including alternative materials used) and metallic materials (interconnect components) are subject of overview. It is established that electrical, mechanical, surface and interfacial phenomena, chemical durability and thermal corrosion behaviour are the key areas for standardization of the materials for SOFC components

  18. 78 FR 73965 - Manufactured Home Construction and Safety Standards

    Science.gov (United States)

    2013-12-09

    ...-free number). Persons with hearing or speech impairments may access this number through TTY by calling... Steel, and Seals. U--ASTM D4635 2001 Standard Specification 3280.611(d). for Polyethylene Films Made... reduce burdens and maintain flexibility and freedom of choice for the public. This rule is not a...

  19. Standard Guide for On-Site Inspection and Verification of Operation of Solar Domestic Hot Water Systems

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1987-01-01

    1.1 This guide covers procedures and test methods for conducting an on-site inspection and acceptance test of an installed domestic hot water system (DHW) using flat plate, concentrating-type collectors or tank absorber systems. 1.2 It is intended as a simple and economical acceptance test to be performed by the system installer or an independent tester to verify that critical components of the system are functioning and to acquire baseline data reflecting overall short term system heat output. 1.3 This guide is not intended to generate accurate measurements of system performance (see ASHRAE standard 95-1981 for a laboratory test) or thermal efficiency. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine th...

  20. Co-operative development of nuclear safety regulations, guides and standards based on NUSS

    International Nuclear Information System (INIS)

    Pachner, J.; Boyd, F.C.; Yaremy, E.M.

    1985-01-01

    A major need of developing Member States building nuclear power plants (NPPs) of foreign origin is to acquire a capability to regulate such nuclear plants independently. Among other things, this requires the development of national nuclear safety regulations, guides and standards to govern the development and use of nuclear technology. Recognizing the importance and complexity of this task, it seems appropriate that the NPP-exporting Member States share their experience and assist the NPP-importing Member States in the development of their national regulations and guides. In 1983, the Atomic Energy Control Board and Atomic Energy of Canada Ltd. conducted a study of a possible joint programme involving Canada, an NPP-importing Member State and the IAEA for the development of the national nuclear safety regulations and guides based on NUSS documents. During the study, a work plan with manpower estimates for the development of design regulations, safety guides and a guide for regulatory evaluation of design was prepared as an investigatory exercise. The work plan suggests that a successful NUSS implementation in developing Member States will require availability of significant resources at the start of the programme. The study showed that such a joint programme could provide an effective mechanism for transfer of nuclear safety know-how to the developing Member States through NUSS implementation. (author)

  1. Standard guide for qualification of measurement methods by a laboratory within the nuclear industry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This guide provides guidance for selecting, validating, and qualifying measurement methods when qualification is required for a specific program. The recommended practices presented in this guide provide a major part of a quality assurance program for the laboratory data (see Fig. 1). Qualification helps to assure that the data produced will meet established requirements. 1.2 The activities intended to assure the quality of analytical laboratory measurement data are diagrammed in Fig. 1. Discussion and guidance related to some of these activities appear in the following sections: Section Selection of Measurement Methods 5 Validation of Measurement Methods 6 Qualification of Measurement Methods 7 Control 8 Personnel Qualification 9 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitati...

  2. Effects of Tempering Temperature and Path on the Microstructural and Mechanical Properties of ASTM Gr.92 Steel

    International Nuclear Information System (INIS)

    Han, C. H.; Baek, J. H.; Kim, S. H.; Lee, C. B.; Kim, Y. K.; Hong, S. I.

    2009-01-01

    SFR (Sodium-Cooled Fast Reactor) is one of the prospective nuclear reactor for the next generation (Gen-IV) systems. The fuel claddings in the SFR are subject to a high fast nuclear irradiation and a high temperature. Fuel technology is a key aspect of an SFR system, with implications for reactor safety, reactor operations, fuel reprocessing technology, and overall system economics. ASTM Gr.92 steel has been considered as the one of the main candidate fuel cladding materials in the design of SFR in that it has higher thermal conductivity as well as dimensional stability under irradiation when compared as austenitic stainless steel. The changes in microstructure and heat-treatment varying M 23 C 6 , MX, M 2 X, and precipitation by ASTM Gr.92 steels to improve high temperature mechanical properties is the attention. According to several researchers, it plays an important role in the mechanical properties of precipitates V, Nb, Cr, C, N as a form of MX and M 2 X precipitates. These fine precipitates formed in the sub- grain by preventing the movement of dislocations in high-temperature mechanical properties will contribute effectively. This study investigated the effects of tempering temperature and heat-treatment path on microstructure and mechanical properties of ASTM Gr.92 steels

  3. A new method to determine J0-integral values (ASTM E 813) without any auxiliary equipment

    International Nuclear Information System (INIS)

    Ullrich, G.; Krompholz, K.

    1987-01-01

    In this contribution the path independent J-integral according to J.R. Rice, respective J.D. Landes and J.A. Begley due to ASTME 813 is calculated by the product J pl = d v J el for 3 point bend type specimen. Here d v is the load point displacement up to the point of the onset of stable crack growth V, which is taken from the load versus load point displacement diagram and J el a value which is equivalent to K 2 /E, where K is the stress intensity factor (ASTME 399) and E is Young's modulus. The advantage of the new procedure is the simplicity of the test arrangement and of the evaluation with the determination of initiation point V without computer or other auxiliary equipment. (orig.) [de

  4. Computed-tomography-guided anatomic standardization for quantitative assessment of dopamine transporter SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Yokoyama, Kota [National Center of Neurology and Psychiatry, Department of Radiology, Tokyo (Japan); National Center of Neurology and Psychiatry, Integrative Brain Imaging Center, Tokyo (Japan); Imabayashi, Etsuko; Matsuda, Hiroshi [National Center of Neurology and Psychiatry, Integrative Brain Imaging Center, Tokyo (Japan); Sumida, Kaoru; Sone, Daichi; Kimura, Yukio; Sato, Noriko [National Center of Neurology and Psychiatry, Department of Radiology, Tokyo (Japan); Mukai, Youhei; Murata, Miho [National Center of Neurology and Psychiatry, Department of Neurology, Tokyo (Japan)

    2017-03-15

    For the quantitative assessment of dopamine transporter (DAT) using [{sup 123}I]FP-CIT single-photon emission computed tomography (SPECT) (DaTscan), anatomic standardization is preferable for achieving objective and user-independent quantification of striatal binding using a volume-of-interest (VOI) template. However, low accumulation of DAT in Parkinson's disease (PD) would lead to a deformation error when using a DaTscan-specific template without any structural information. To avoid this deformation error, we applied computed tomography (CT) data obtained using SPECT/CT equipment to anatomic standardization. We retrospectively analyzed DaTscan images of 130 patients with parkinsonian syndromes (PS), including 80 PD and 50 non-PD patients. First we segmented gray matter from CT images using statistical parametric mapping 12 (SPM12). These gray-matter images were then anatomically standardized using the diffeomorphic anatomical registration using exponentiated Lie algebra (DARTEL) algorithm. Next, DaTscan images were warped with the same parameters used in the CT anatomic standardization. The target striatal VOIs for decreased DAT in PD were generated from the SPM12 group comparison of 20 DaTscan images from each group. We applied these VOIs to DaTscan images of the remaining patients in both groups and calculated the specific binding ratios (SBRs) using nonspecific counts in a reference area. In terms of the differential diagnosis of PD and non-PD groups using SBR, we compared the present method with two other methods, DaTQUANT and DaTView, which have already been released as software programs for the quantitative assessment of DaTscan images. The SPM12 group comparison showed a significant DAT decrease in PD patients in the bilateral whole striatum. Of the three methods assessed, the present CT-guided method showed the greatest power for discriminating PD and non-PD groups, as it completely separated the two groups. CT-guided anatomic standardization using

  5. Biocompatibility of metal injection molded versus wrought ASTM F562 (MP35N) and ASTM F1537 (CCM) cobalt alloys.

    Science.gov (United States)

    Chen, Hao; Sago, Alan; West, Shari; Farina, Jeff; Eckert, John; Broadley, Mark

    2011-01-01

    We present a comparative analysis between biocompatibility test results of wrought and Metal Injection Molded (MIM) ASTM F562-02 UNS R30035 (MP35N) and F1537 UNS R31538 (CCM) alloy samples that have undergone the same generic orthopedic implant's mechanical, chemical surface pre-treatment, and a designed pre-testing sample preparation method. Because the biocompatibility properties resulting from this new MIM cobalt alloy process are not well understood, we conducted tests to evaluate cytotoxicity (in vitro), hemolysis (in vitro), toxicity effects (in vivo), tissue irritation level (in vivo), and pyrogenicity count (in vitro) on such samples. We show that our developed MIM MP35N and CCM materials and treatment processes are biocompatible, and that both the MIM and wrought samples, although somewhat different in microstructure and surface, do not show significant differences in biocompatibility.

  6. Value-Based Standards Guide Sexism Inferences for Self and Others.

    Science.gov (United States)

    Mitamura, Chelsea; Erickson, Lynnsey; Devine, Patricia G

    2017-09-01

    People often disagree about what constitutes sexism, and these disagreements can be both socially and legally consequential. It is unclear, however, why or how people come to different conclusions about whether something or someone is sexist. Previous research on judgments about sexism has focused on the perceiver's gender and attitudes, but neither of these variables identifies comparative standards that people use to determine whether any given behavior (or person) is sexist. Extending Devine and colleagues' values framework (Devine, Monteith, Zuwerink, & Elliot, 1991; Plant & Devine, 1998), we argue that, when evaluating others' behavior, perceivers rely on the morally-prescriptive values that guide their own behavior toward women. In a series of 3 studies we demonstrate that (1) people's personal standards for sexism in their own and others' behavior are each related to their values regarding sexism, (2) these values predict how much behavioral evidence people need to infer sexism, and (3) people with stringent, but not lenient, value-based standards get angry and try to regulate a sexist perpetrator's behavior to reduce sexism. Furthermore, these personal values are related to all outcomes in the present work above and beyond other person characteristics previously used to predict sexism inferences. We discuss the implications of differing value-based standards for explaining and reconciling disputes over what constitutes sexist behavior.

  7. 75 FR 39871 - Manufactured Home Construction and Safety Standards

    Science.gov (United States)

    2010-07-13

    ... (ANSI A208.2-2004) and would require no change in existing technology for either product to achieve the... certificates required by this section would be amended to refer to the 1997 edition of the ASHRAE Handbook of... for Bathing Facilities. U--ASTM C564 1997 Standard Specification for Rubber 3280.611(d) Gaskets for...

  8. Standard guide for determining corrosivity of crude oils

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This guide presents some generally accepted laboratory methodologies that are used for determining the corrosivity of crude oil. 1.2 This guide does not cover detailed calculations and methods, but rather a range of approaches that have found application in evaluating the corrosivity of crude oil. 1.3 Only those methodologies that have found wide acceptance in crude oil corrosivity evaluation are considered in this guide. 1.4 This guide does not address the change in oil/water ratio caused by accumulation of water at low points in a pipeline system. 1.5 This guide is intended to assist in the selection of methodologies that can be used for determining the corrosivity of crude oil under conditions in which water is present in the liquid state (typically up to 100°C). These conditions normally occur during oil and gas production, storage, and transportation in the pipelines. 1.6 This guide does not cover the evaluation of corrosivity of crude oil at higher temperatures (typically above 300°C) that oc...

  9. Application of MCDM based hybrid optimization tool during turning of ASTM A588

    Directory of Open Access Journals (Sweden)

    Himadri Majumder

    2017-07-01

    Full Text Available Multi-criteria decision making approach is one of the most troublesome tools for solving the tangled optimization problems in the machining area due to its capability of solving the complex optimization problems in the production process. Turning is widely used in the manufacturing processes as it offers enormous advantages like good quality product, customer satisfaction, economical and relatively easy to apply. A contemporary approach, MOORA coupled with PCA, was used to ascertain an optimal combination of input parameters (spindle speed, depth of cut and feed rate for the given output parameters (power consumption, average surface roughness and frequency of tool vibration using L27 orthogonal array for turning on ASTM A588 mild steel. Comparison between MOORA-PCA and TOPSIS-PCA shows the effectiveness of MOORA over TOPSIS method. The optimum parameter combination for multi-performance characteristics has been established for ASTM A588 mild steel are spindle speed 160 rpm, depth of cut 0.1 mm and feed rate 0.08 mm/rev. Therefore, this study focuses on the application of the hybrid MCDM approach as a vital selection making tool to deal with multi objective optimization problems.

  10. Living Traditions--A Teacher's Guide: Teaching Local History Using State and National Learning Standards.

    Science.gov (United States)

    Skelding, Mark; Kemple, Martin; Kiefer, Joseph

    This guide is designed to take teachers through a step-by-step process for developing an integrated, standards-based curriculum that focuses on the stories, history, folkways, and agrarian traditions of the local community. Such a place-based curriculum helps students to become culturally literate, makes learning relevant and engaging, draws on…

  11. Guide to nondestructive assay standards: Preparation criteria, availability, and practical considerations

    International Nuclear Information System (INIS)

    Stewart, J.E.; Hsue, S.T.; Sampson, T.E.

    1997-01-01

    For certification and measurement control, nondestructive assay (NDA) instruments and methods used for verification measurement of special nuclear materials (SNMs) require calibrations based on certified reference materials (CRMs), or working reference materials (WRMs), traceable to the national system of measurements, and adequately characteristic of the unknowns. The Department of Energy Office of Safeguards and Security is sponsoring production of a comprehensive guide to preparation of NDA standards. The scope of the report includes preparation criteria, current availability of CRMs and WRMs, practical considerations for preparation and characterization, and an extensive bibliography. In preparing the report, based primarily on experience at Los Alamos, we have found that standards preparation is highly dependent on the particular NDA method being applied. We therefore include sections that contain information specific to commonly used neutron and gamma-ray NDA techniques. 16 refs., 4 figs., 2 tabs

  12. Adding Bite to the Bark: Using LibGuides2 Migration as Impetus to Introduce Strong Content Standards

    Science.gov (United States)

    Fritch, Melia; Pitts, Joelle E.

    2016-01-01

    The authors discuss the long-term accumulation of unstandardized and inaccessible content within the Libguides system and the decision-making process to create and implement a set of standards using the migration to the LibGuides2 platform as a vehicle for change. Included in the discussion are strategies for the creation of standards and…

  13. MÉTODOS PARA CARACTERIZAR COMBUSTIBLES LÍQUIDOS Y GASEOSOS OBTENIDOS DE LLANTAS EN DESUSO A TRAVÉS DE LAS NORMAS ASTM.

    Directory of Open Access Journals (Sweden)

    JAIME ALEJANDRO OSPINA

    2011-12-01

    Full Text Available Este artículo muestra la importancia de la caracterización de la energía de combustibles líquidos y gaseosos obtenidos del conocido tratamiento térmico de pirolisis a través de un microondas. La caracterización de estos combustibles tomará en cuenta los estándares técnicos tales como ASTM D3452 – 93 para la cromatografía de gases (GC, ASTM D2549 para cromatografía de gas/ espectrometría de masa (GC/MS y ASTM D6370 -99 para termogravimetría en el análisis de la composición de llantas.También muestra que estos combustibles y gases de pirolisis tiene una alta valor calorífico de 42 MJ / Kg y un contenido de azufre entre 0.8 y 1.65 Wt%, dependiendo en el tipo de llanta y las condiciones del proceso.

  14. Standard Guide for Irradiation of Dried Spices, Herbs, and Vegetable Seasonings to Control Pathogens and Other Microorganisms

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This guide covers procedures for irradiation of dried spices, herbs, and vegetable seasonings for microbiological control. Generally, these items have moisture content of 4.5 to 12 % and are available in whole, ground, chopped, or other finely divided forms, or as blends. The blends may contain sodium chloride and minor amounts of dry food materials ordinarily used in such blends. 1.2 This guide covers absorbed doses ranging from 3 to 30 kiloGray (kGy). Note 1—U.S. regulations permit a maximum dose of 30 kGy. (See 21CFR 179.26 Irradiation in the Production, Processing and Handling of Food.) 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  15. Comparative Study of API 5L X60 and ASTM 572 Gr50 Steel Exposed to Crude Oil and Seawater

    Directory of Open Access Journals (Sweden)

    Marcy Viviana Chiquillo Márquez

    2018-04-01

    Full Text Available In the petroleum industry, the biphasic conditions in storage and separation tanks allow that the material to remain exposed to two different environments, causing its deterioration. In this article, an evaluation is made of the corrosive behavior and Vickers microhardness (HV of two high strength low alloy (HSLA steels and how their surfaces are characterized. The ASTM 572 Gr50 steel showed a lower corrosion rate in all systems after being immersed for 720 and 1440 hours. Characterizing the surface by means of Scanning Electron Microscopy (SEM showed uniform and localized corrosion for the both steels, and revealed that the ASTM 572 Gr50 steel shows pitting corrosion in crude oil systems. The electrochemical results revealed that the corrosion potential of API X60 steel was more negative; however the ASTM 572 Gr50 steel had a higher current density and a lower polarization resistance when immersed in an oil/seawater mixture. It also observed that, after being immersed in the corrosive fluids, the microstructures of the steels were not modified and variations in their microhardness (HV were minute.

  16. Standard guide for estimating the atmospheric corrosion resistance of low-alloy steels

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This guide presents two methods for estimating the atmospheric corrosion resistance of low-alloy weathering steels, such as those described in Specifications A242/A242M, A588/A588M, A606 Type 4, A709/A709M grades 50W, HPS 70W, and 100W, A852/A852M, and A871/A871M. One method gives an estimate of the long-term thickness loss of a steel at a specific site based on results of short-term tests. The other gives an estimate of relative corrosion resistance based on chemical composition. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

  17. Standard Guide for Acousto-Ultrasonic Assessment of Composites, Laminates, and Bonded Joints

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This guide explains the rationale and basic technology for the acousto-ultrasonic (AU) method. Guidelines are given for nondestructive evaluation (NDE) of flaws and physical characteristics that influence the mechanical properties and relative strength of composite structures (for example, filament-wound pressure vessels), adhesive bonds (for example, joints between metal plates), and interlaminar and fiber/matrix bonds in man-made composites and natural composites (for example, wood products). 1.2 This guide covers technical details and rules that must be observed to ensure reliable and reproducible quantitative AU assessments of laminates, composites, and bonded structures. The underlying principles, prototype apparatus, instrumentation, standardization, examination methods, and data analysis for such assessments are covered. Limitations of the AU method and guidelines for taking advantage of its capabilities are cited. 1.3 The objective of AU is to assess subtle flaws and associated strength variations...

  18. Standard Practice for Dosimetry of Proton Beams for use in Radiation Effects Testing of Electronics

    Energy Technology Data Exchange (ETDEWEB)

    McMahan, Margaret A.; Blackmore, Ewart; Cascio, Ethan W.; Castaneda, Carlos; von Przewoski, Barbara; Eisen, Harvey

    2008-07-25

    Representatives of facilities that routinely deliver protons for radiation effect testing are collaborating to establish a set of standard best practices for proton dosimetry. These best practices will be submitted to the ASTM International for adoption.

  19. Standard Practice for Dosimetry of Proton Beams for use in Radiation Effects Testing of Electronics

    International Nuclear Information System (INIS)

    McMahan, Margaret A.; Blackmore, Ewart; Cascio, Ethan W.; Castaneda, Carlos; von Przewoski, Barbara; Eisen, Harvey

    2008-01-01

    Representatives of facilities that routinely deliver protons for radiation effect testing are collaborating to establish a set of standard best practices for proton dosimetry. These best practices will be submitted to the ASTM International for adoption

  20. A Guide for Developing Standard Operating Job Procedures for the Screening & Grinding Process Wastewater Treatment Facility. SOJP No. 1.

    Science.gov (United States)

    Deal, Gerald A.; Montgomery, James A.

    This guide describes standard operating job procedures for the screening and grinding process of wastewater treatment facilities. The objective of this process is the removal of coarse materials from the raw waste stream for the protection of subsequent equipment and processes. The guide gives step-by-step instructions for safety inspection,…

  1. A non-freaked out guide to teaching the common core using the 32 literacy anchor standards to develop college- and career-ready students

    CERN Document Server

    Stuart, Dave

    2014-01-01

    Implement the Common Core for ELA without all the stress A Non-Freaked Out Guide to Teaching the Common Core uses the often-neglected anchor standards to get to the heart of the Common Core State Standards (CCSS)-teaching students the skills they need to be college and career ready. Each anchor standard is broken down into its key points, and a discussion of each anchor standard''s central purpose helps outline the context for each required skill. This easy-to-read guide gives educators the kind of clear explanations, examples, and strategies they need to feel comfortable teaching the CCSS, an

  2. 77 FR 70390 - Lifesaving Equipment: Production Testing and Harmonization With International Standards

    Science.gov (United States)

    2012-11-26

    ... components within the system to be made of corrosion-resistant materials without the need for galvanizing... resistant in the marine environment without the need for coatings or galvanizing,'' the current ASTM.... This standard would no longer be appropriate because these steels require coatings or galvanizing to be...

  3. A standardized evaluation of artifacts from metallic compounds during fast MR imaging

    DEFF Research Database (Denmark)

    Murakami, Shumei; Verdonschot, Rinus G; Kataoka, Miyoshi

    2016-01-01

    according to the ASTM-F2119 standard and artifact volumes were assessed using OsiriX MD software Results: Tukey-Kramer post-hoc tests were used for statistical comparisons. For most materials, scanning sequences eliciting artifact volumes in the following (ascending) order FSE-T1/FSE-T2

  4. Mode II Interlaminar Fracture Toughness and Fatigue Characterization of a Graphite Epoxy Composite Material

    Science.gov (United States)

    O'Brien, T. Kevin; Johnston, William M.; Toland, Gregory J.

    2010-01-01

    Mode II interlaminar fracture toughness and delamination onset and growth characterization data were generated for IM7/8552 graphite epoxy composite materials from two suppliers for use in fracture mechanics analyses. Both the fracture toughness testing and the fatigue testing were conducted using the End-notched Flexure (ENF) test. The ENF test for mode II fracture toughness is currently under review by ASTM as a potential standard test method. This current draft ASTM protocol was used as a guide to conduct the tests on the IM7/8552 material. This report summarizes the test approach, methods, procedures and results of this characterization effort.

  5. 76 FR 55056 - Toy Safety Standard: Strategic Outreach and Education Plan

    Science.gov (United States)

    2011-09-06

    ... to test and certify to the toy safety standard. We plan to use traditional and social media to... testing and certification requirements for children's toys and toy chests and their compliance with ASTM... manufacturers of children's toys must ensure that covered toys are tested for compliance with the toy safety...

  6. Whole glove permeation of cyclohexanol through disposable nitrile gloves on a dextrous robot hand and comparison with the modified closed-loop ASTM F739 method 1. No fist clenching.

    Science.gov (United States)

    Mathews, Airek R; Que Hee, Shane S

    2017-04-01

    The aim was to develop a whole glove permeation method for cyclohexanol to generate permeation parameter data for a non-moving dextrous robot hand (normalized breakthrough time t b , standardized breakthrough time t s , steady state permeation rate P s , and diffusion coefficient D). Four types of disposable powderless, unsupported, and unlined nitrile gloves from the same producer were investigated: Safeskin Blue and Kimtech Science Blue, Purple, and Sterling. The whole glove method developed involved a peristaltic pump for water circulation through chemically resistant Viton tubing to continually wash the inner surface of the test glove via holes in the tubing, a dextrous robot hand operated by a microprocessor, a chemically protective nitrile glove to protect the robot hand, an incubator to maintain 35°C temperature, and a hot plate to maintain 35°C at the sampling point of the circulating water. Aliquots of 1.0 mL were sampled at regular time intervals for the first 60 min followed by removal of 0.5 mL aliquots every hour to 8 hr. Quantification was by the internal standard method after gas chromatography-selective ion electron impact mass spectrometry using a non-polar capillary column. The individual glove values of t b and t s differed for the ASTM closed loop method except for Safeskin Blue, but did not for the whole glove method. Most of the kinetic parameters agreed within an order of magnitude for the two techniques. The order of most protective to least protective glove was Blue and Safeskin, then Purple followed by Sterling for the whole gloves. The analogous order for the modified F739 ASTM closed loop method was: Safeskin, Blue, Purple, and Sterling, almost the same as for the whole glove. The Sterling glove was "not recommended" from the modified ASTM data, and was "poor" from the whole glove data.

  7. 77 FR 56809 - Certain Small Diameter Seamless Carbon and Alloy Steel Standard, Line, and Pressure Pipe From...

    Science.gov (United States)

    2012-09-14

    ... stress levels. Alloy pipes made to ASTM standard A-335 must be used if temperatures and stress levels... not used in standard, line or pressure applications. In addition, finished and unfinished oil country... antidumping duty order from the same country. If not covered by such an OCTG order, finished and unfinished...

  8. Standard guide for use of UV-A and visible light sources and meters used in the liquid penetrant and magnetic particle methods

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This guide describes the use of UV-A/Visible light sources and meters used for the examination of materials by the liquid penetrant and magnetic particle processes. This guide may be used to help support the needs for appropriate light intensities and light measurement. 1.2 This guide also provides a reference: 1.2.1 To assist in the selection of light sources and meters that meet the applicable specifications or standards. 1.2.2 For use in the preparation of internal documentation dealing with liquid penetrant or magnetic particle examination of materials and parts. 1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and det...

  9. How to achieve ultrasound-guided femoral venous access: the new standard of care in the electrophysiology laboratory.

    Science.gov (United States)

    Wiles, Benedict M; Child, Nicholas; Roberts, Paul R

    2017-06-01

    Bedside vascular ultrasound machines are increasingly available. They are used to facilitate safer vascular access across a number of different specialties. In the electrophysiology laboratory however, where patients are frequently anticoagulated and require the insertion of multiple venous sheaths, anatomical landmark techniques predominate. Despite the high number of vascular complications associated with electrophysiological procedures and the increasing evidence to support its use in electrophysiology, ultrasound remains underutilised. A new standard of care is required. A comprehensive technical report, providing a detailed explanation of this important technique, will provide other electrophysiology centres with the knowledge and justification for adopting ultrasound guidance as their standard practice. We review the increasing body of evidence which demonstrates that routine ultrasound usage can substantially improve the safety of femoral venous access in the electrophysiology laboratory. We offer a comprehensive technical report to guide operators through the process of ultrasound-guided venous access, with a specific focus on the electrophysiology laboratory. Additionally, we detail a novel technique which utilises real-time colour Doppler ultrasound to accurately identify needle tip location during venous puncture. The use of vascular ultrasound to guide femoral venous cannulation is rapid, inexpensive and easily learnt. Ultrasound is readily available and offers the potential to significantly reduce vascular complications in the unique setting of the electrophysiology laboratory. Ultrasound guidance to achieve femoral venous access should be the new standard of care in electrophysiology.

  10. VALIDATION OF ANALYTICAL METHODS AND INSTRUMENTATION FOR BERYLLIUM MEASUREMENT: REVIEW AND SUMMARY OF AVAILABLE GUIDES, PROCEDURES, AND PROTOCOLS

    Energy Technology Data Exchange (ETDEWEB)

    Ekechukwu, A.

    2008-12-17

    This document proposes to provide a listing of available sources which can be used to validate analytical methods and/or instrumentation for beryllium determination. A literature review was conducted of available standard methods and publications used for method validation and/or quality control. A comprehensive listing of the articles, papers, and books reviewed is given in Appendix 1. Available validation documents and guides are listed in the appendix; each has a brief description of application and use. In the referenced sources, there are varying approaches to validation and varying descriptions of validation at different stages in method development. This discussion focuses on validation and verification of fully developed methods and instrumentation that have been offered up for use or approval by other laboratories or official consensus bodies such as ASTM International, the International Standards Organization (ISO) and the Association of Official Analytical Chemists (AOAC). This review was conducted as part of a collaborative effort to investigate and improve the state of validation for measuring beryllium in the workplace and the environment. Documents and publications from the United States and Europe are included. Unless otherwise specified, all documents were published in English.

  11. Nondestructive testing standards and the ASME code

    International Nuclear Information System (INIS)

    Spanner, J.C.

    1991-04-01

    Nondestructive testing (NDT) requirements and standards are an important part of the ASME Boiler and Pressure Vessel Code. In this paper, the evolution of these requirements and standards is reviewed in the context of the unique technical and legal stature of the ASME Code. The coherent and consistent manner by which the ASME Code rules are organized is described, and the interrelationship between the various ASME Code sections, the piping codes, and the ASTM Standards is discussed. Significant changes occurred in ASME Sections 5 and 11 during the 1980s, and these are highlighted along with projections and comments regarding future trends and changes in these important documents. 4 refs., 8 tabs

  12. Standard Guide for Use of Melt Wire Temperature Monitors for Reactor Vessel Surveillance, E 706 (IIIE)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This guide describes the application of melt wire temperature monitors and their use for reactor vessel surveillance of light-water power reactors as called for in Practice E 185. 1.2 The purpose of this guide is to recommend the selection and use of the common melt wire technique where the correspondence between melting temperature and composition of different alloys is used as a passive temperature monitor. Guidelines are provided for the selection and calibration of monitor materials; design, fabrication, and assembly of monitor and container; post-irradiation examinations; interpretation of the results; and estimation of uncertainties. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (See Note 1.)

  13. Reactor pressure vessel steels ASTM A533B and A508 Cl.2

    International Nuclear Information System (INIS)

    Pelli, R.; Kemppainen, M.; Toerroenen, K.

    1979-11-01

    This report presents the tensile test results of steels ASTM A533B and A508 Cl.2 obtained in connection with a programme initiated to gather and create information needed for the assessment of the structural integrity of the reactor pressure vessels. The tensile properties were studied between -196 and 300 degC varying austenitizing and tempering temperatures and having two different carbon contents for the heats of A533B. (author)

  14. Recommendations for Autonomous Industrial Vehicle Performance Standards

    OpenAIRE

    Bostelman , Roger

    2016-01-01

    International audience; A workshop was held at the IEEE International Conference on Robotics and Automation, called: “Autonomous Industrial Vehicles: From the Laboratory to the Factory Floor”. Nine research papers were presented followed by a discussion session summarized in this paper. The workshop findings are intended to be useful for developing standards within the ASTM F45 Committee for Driverless Automatic Industrial Vehicles. This paper provides feedback from the discussion listing the...

  15. Image-guided Tumor Ablation: Standardization of Terminology and Reporting Criteria—A 10-Year Update

    Science.gov (United States)

    Solbiati, Luigi; Brace, Christopher L.; Breen, David J.; Callstrom, Matthew R.; Charboneau, J. William; Chen, Min-Hua; Choi, Byung Ihn; de Baère, Thierry; Dodd, Gerald D.; Dupuy, Damian E.; Gervais, Debra A.; Gianfelice, David; Gillams, Alice R.; Lee, Fred T.; Leen, Edward; Lencioni, Riccardo; Littrup, Peter J.; Livraghi, Tito; Lu, David S.; McGahan, John P.; Meloni, Maria Franca; Nikolic, Boris; Pereira, Philippe L.; Liang, Ping; Rhim, Hyunchul; Rose, Steven C.; Salem, Riad; Sofocleous, Constantinos T.; Solomon, Stephen B.; Soulen, Michael C.; Tanaka, Masatoshi; Vogl, Thomas J.; Wood, Bradford J.; Goldberg, S. Nahum

    2014-01-01

    Image-guided tumor ablation has become a well-established hallmark of local cancer therapy. The breadth of options available in this growing field increases the need for standardization of terminology and reporting criteria to facilitate effective communication of ideas and appropriate comparison among treatments that use different technologies, such as chemical (eg, ethanol or acetic acid) ablation, thermal therapies (eg, radiofrequency, laser, microwave, focused ultrasound, and cryoablation) and newer ablative modalities such as irreversible electroporation. This updated consensus document provides a framework that will facilitate the clearest communication among investigators regarding ablative technologies. An appropriate vehicle is proposed for reporting the various aspects of image-guided ablation therapy including classification of therapies, procedure terms, descriptors of imaging guidance, and terminology for imaging and pathologic findings. Methods are addressed for standardizing reporting of technique, follow-up, complications, and clinical results. As noted in the original document from 2003, adherence to the recommendations will improve the precision of communications in this field, leading to more accurate comparison of technologies and results, and ultimately to improved patient outcomes. © RSNA, 2014 Online supplemental material is available for this article. PMID:24927329

  16. Ensaios MSCR segundo as normas ASTM D7405-10a e AASHTO T350-14: um estudo de caso envolvendo ligantes asfálticos modificados

    Directory of Open Access Journals (Sweden)

    Matheus David Inocente Domingos

    2016-12-01

    especially the AC+rubber and the AC+rubber+PPA. The AC+PPA showed low stress sensitivity and the best results for the parameters R and Jnr at 3,200 Pa either in the ASTM or the AASHTO protocols, which justifies its choice as the best formulation. The data from the modified asphalt binders suggest that the change from the ASTM protocol to the AASHTO one is recommended.

  17. Standard guide for making quality nondestructive assay measurements

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This guide is a compendium of Quality Measurement Practices for performing measurements of radioactive material using nondestructive assay (NDA) instruments. The primary purpose of the guide is to assist users in arriving at quality NDA results, that is, results that satisfy the end user’s needs. This is accomplished by providing an acceptable and uniform basis for the collection, analysis, comparison, and application of data. The recommendations are not compulsory or prerequisites to achieving quality NDA measurements, but are considered contributory in most areas. 1.2 This guide applies to the use of NDA instrumentation for the measurement of nuclear materials by the observation of spontaneous or stimulated nuclear radiations, including photons, neutrons, or the flow of heat. Recommended calibration, operating, and assurance methods represent guiding principles based on current NDA technology. The diversity of industry-wide nuclear materials measurement applications and instrumentation precludes disc...

  18. Pocket companion to PMI's PMBOK guide

    CERN Document Server

    Snijders, Paul; Zandhuis, Anton

    2010-01-01

    This pocket guide is based on the PMBOK Guide® Fourth Edition.This pocket guide supplies a summary of the PMBOK Guide® , to provide a quick introduction as well as a structured overview of this method for project management.This pocket guide deals with the key issues and themes within project management and PMBOK:A short overview of the activities of PMI Inc., The organization and its standards: PMBOK Guide®, Standard for Project Portfolio Management, Standard for Program Management, OPM3.The essentials of the Project Lifecycle and Organization.What are the key project management knowledge ar

  19. Safety guides development process in Spain

    International Nuclear Information System (INIS)

    Butragueno, J.L.; Perello, M.

    1979-01-01

    Safety guides have become a major factor in the licensing process of nuclear power plants and related nuclear facilities of the fuel cycle. As far as the experience corroborates better and better engineering methodologies and procedures, the results of these are settled down in form of standards, guides, and similar issues. This paper presents the actual Spanish experience in nuclear standards and safety guides development. The process to develop a standard or safety guide is shown. Up to date list of issued and on development nuclear safety guides is included and comments on the future role of nuclear standards in the licensing process are made. (author)

  20. Standard guide for application of radiation monitors to the control and physical security of special nuclear material

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    This guide briefly describes the state-of-the-art of radiation monitors for detecting special nuclear material (SNM) in order to establish the context in which to write performance standards for the monitors. This guide extracts information from technical documentation to provide information for selecting, calibrating, testing, and operating such radiation monitors when they are used for the control and protection of SNM. This guide offers an unobtrusive means of searching pedestrians, packages, and motor vehicles for concealed SNM as one part of a nuclear material control or security plan for nuclear materials. The radiation monitors can provide an efficient, sensitive, and reliable means of detecting the theft of small quantities of SNM while maintaining a low likelihood of nuisance alarms

  1. Rationale and development of image-guided intensity-modulated radiotherapy post-prostatectomy: the present standard of care?

    Directory of Open Access Journals (Sweden)

    Murray JR

    2015-11-01

    Full Text Available Julia R Murray,1,2 Helen A McNair,2 David P Dearnaley1,2 1Academic Urology Unit, Institute of Cancer Research, London, 2Department of Radiotherapy, The Royal Marsden NHS Foundation Trust, Sutton, UK Abstract: The indications for post-prostatectomy radiotherapy have evolved over the last decade, although the optimal timing, dose, and target volume remain to be well defined. The target volume is susceptible to anatomical variations with its borders interfacing with the rectum and bladder. Image-guided intensity-modulated radiotherapy has become the gold standard for radical prostate radiotherapy. Here we review the current evidence for image-guided techniques with intensity-modulated radiotherapy to the prostate bed and describe current strategies to reduce or account for interfraction and intrafraction motion. Keywords: radiotherapy, prostate cancer, post-prostatectomy, image-guided radiation therapy

  2. Defense Standardization Program Journal. April/June 2011

    Science.gov (United States)

    2011-06-01

    years, the seven winners have played an integral part in keeping our men and women in uniform sate and in providing them the tools they need to get...supporting our men and women in uniform, helping to multiply capability through interoperability, and saving money tor the taxpayer. 1 hope that reading...committee chair of ASTM B687, "Standard Specifi- cation for Brass, Copper, and Chromium-Plated Pipe Nipples " (FSC 4730), to incor- porate eight additional

  3. A proposed standard round compact specimen for plane strain fracture toughness testing

    Science.gov (United States)

    Underwood, J. H.; Newman, J. C., Jr.; Seeley, R. R.

    1980-01-01

    A round, disk-shaped specimen is proposed as a standard test specimen for addition to ASTM Test for Plane-Strain Fracture Toughness of Metallic Materials (E 399-78A). The specimen is diametrically cracked, and loaded in the same way as the existing standard compact specimen. Tests and analyses were performed to verify that the proposed round compact specimen and associated stress intensity factor K solution are appropriate for a standard plane strain fracture toughness test. The use of the round compact specimen for other fracture tests is described.

  4. Standard Guide for Radiation Protection Program for Decommissioning Operations

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1987-01-01

    1.1 This guide provides instruction to the individual charged with the responsibility for developing and implementing the radiation protection program for decommissioning operations. 1.2 This guide provides a basis for the user to develop radiation protection program documentation that will support both the radiological engineering and radiation safety aspects of the decommissioning project. 1.3 This guide presents a description of those elements that should be addressed in a specific radiation protection plan for each decommissioning project. The plan would, in turn, form the basis for development of the implementation procedures that execute the intent of the plan. 1.4 This guide applies to the development of radiation protection programs established to control exposures to radiation and radioactive materials associated with the decommissioning of nuclear facilities. The intent of this guide is to supplement existing radiation protection programs as they may pertain to decommissioning workers, members of...

  5. Standard guide for establishing a quality assurance program for uranium conversion facilities

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This guide provides guidance and recommended practices for establishing a comprehensive quality assurance program for uranium conversion facilities. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate health and safety practices and determine the applicability of regulatory limitations prior to use. 1.3 The basic elements of a quality assurance program appear in the following order: FUNCTION SECTION Organization 5 Quality Assurance Program 6 Design Control 7 Instructions, Procedures & Drawings 8 Document Control 9 Procurement 10 Identification and Traceability 11 Processes 12 Inspection 13 Control of Measuring and Test Equipment 14 Handling, Storage and Shipping 15 Inspection, Test and Operating Status 16 Control of Nonconforming Items 17 Corrective Actions 18 Quality Assurance Records 19 Audits 20 TABLE 1 NQA-1 Basic Requirements Relat...

  6. IC3 Internet and Computing Core Certification Global Standard 4 study guide

    CERN Document Server

    Rusen, Ciprian Adrian

    2015-01-01

    Hands-on IC3 prep, with expert instruction and loads of tools IC3: Internet and Computing Core Certification Global Standard 4 Study Guide is the ideal all-in-one resource for those preparing to take the exam for the internationally-recognized IT computing fundamentals credential. Designed to help candidates pinpoint weak areas while there's still time to brush up, this book provides one hundred percent coverage of the exam objectives for all three modules of the IC3-GS4 exam. Readers will find clear, concise information, hands-on examples, and self-paced exercises that demonstrate how to per

  7. 76 FR 39852 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe (Over 41/2

    Science.gov (United States)

    2011-07-07

    ..., or equivalent, to the American Society for Testing and Materials (``ASTM'') A-53, ASTM A-106, ASTM A-333, ASTM A- 334, ASTM A-589, ASTM A-795, and the American Petroleum Institute (``API'') 5L... American Society of Mechanical Engineers (``ASME'') code stress levels. Alloy pipes made to ASTM A-335...

  8. 77 FR 13079 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe (Over 41/2

    Science.gov (United States)

    2012-03-05

    ... produced, or equivalent, to the American Society for Testing and Materials (``ASTM'') A-53, ASTM A-106, ASTM A-333, ASTM A- 334, ASTM A-589, ASTM A-795, and the American Petroleum Institute (``API'') 5L... American Society of Mechanical Engineers (``ASME'') code stress levels. Alloy pipes made to ASTM A-335...

  9. Simplification and transformation of ASTM F1292 measurement procedure for fall accident injury criteria.

    Science.gov (United States)

    Kato, Maki; Shimodaira, Yoshie; Sato, Takeshi; Iida, Hiromi

    2014-01-01

    Protecting children from injuries caused by fall accidents from playground equipment is important. Therefore, measures toward minimizing the risk of fall accident injuries are required. The risk of injury can be evaluated using ASTM F1292. In this test, G-max and the HIC are used to estimate the risk of injury. However, the measurement procedure is too complicated for application to a large number of installed equipment. F1292 requires simplified by reducing the number of phases, even with a small risk of loss in accuracy. With this in mind, this study proposes a shortened measurement procedure and a transformation equation to estimate the risk as same as F1292. As the result of experiments, it was revealed that G-max and the HIC values for both procedures linearly increase with drop height. The differences in outcomes between the regression equations of the standardized procedure and those of the shortened procedure can be used as a correction value. They can be added to the value measured by the shortened procedure. This suggests that the combination of the shortened procedure and transformation equation would be equivalent to F1292, with the advantage of being more easily and efficiently applied to the evaluation of installed playground equipment.

  10. Repeatability and Reproducibility of Compression Strength Measurements Conducted According to ASTM E9

    Science.gov (United States)

    Luecke, William E.; Ma, Li; Graham, Stephen M.; Adler, Matthew A.

    2010-01-01

    Ten commercial laboratories participated in an interlaboratory study to establish the repeatability and reproducibility of compression strength tests conducted according to ASTM International Standard Test Method E9. The test employed a cylindrical aluminum AA2024-T351 test specimen. Participants measured elastic modulus and 0.2 % offset yield strength, YS(0.2 % offset), using an extensometer attached to the specimen. The repeatability and reproducibility of the yield strength measurement, expressed as coefficient of variations were cv(sub r)= 0.011 and cv(sub R)= 0.020 The reproducibility of the test across the laboratories was among the best that has been reported for uniaxial tests. The reported data indicated that using diametrically opposed extensometers, instead of a single extensometer doubled the precision of the test method. Laboratories that did not lubricate the ends of the specimen measured yield stresses and elastic moduli that were smaller than those measured in laboratories that lubricated the specimen ends. A finite element analysis of the test specimen deformation for frictionless and perfect friction could not explain the discrepancy, however. The modulus measured from stress-strain data were reanalyzed using a technique that finds the optimal fit range, and applies several quality checks to the data. The error in modulus measurements from stress-strain curves generally increased as the fit range decreased to less than 40 % of the stress range.

  11. Standard guide for fretting fatigue testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This guide defines terminology and covers general requirements for conducting fretting fatigue tests and reporting the results. It describes the general types of fretting fatigue tests and provides some suggestions on developing and conducting fretting fatigue test programs. 1.2 Fretting fatigue tests are designed to determine the effects of mechanical and environmental parameters on the fretting fatigue behavior of metallic materials. This guide is not intended to establish preference of one apparatus or specimen design over others, but will establish guidelines for adherence in the design, calibration, and use of fretting fatigue apparatus and recommend the means to collect, record, and reporting of the data. 1.3 The number of cycles to form a fretting fatigue crack is dependent on both the material of the fatigue specimen and fretting pad, the geometry of contact between the two, and the method by which the loading and displacement are imposed. Similar to wear behavior of materials, it is important t...

  12. Anodic Protection performance of Steels ASTM A 516-60 And JIS G 3131 SPHC In Concentrated Sulfuric Acid

    International Nuclear Information System (INIS)

    Harsisto; Ginting, Immanuel; Eddy, D.C

    2001-01-01

    One of the methods to protect a carbon steel material from corrosion attack of sulfuric acid environment is with anodic protection. This research was intended to investigate the effect of anodic protection quickened with potential polarization, The material under investigation were ASTM A 516 and JIS G 3131-SPHC in highly concentrated H 2 SO 4 solution. The results showed that potential that was effective for anodic protection in ASTM A 516-60 were at 236-436 mV for 75%, 276-476 mV for 80%, 264-514 mV for 85%,285-485 mV for 90%, and 231-431 mV for 97% H 2 SO 4 so that in JlS G 3131-SPHC were at 303 -503 mV for 75%, 290-490 mV for 80%, 269- 516 mV for 85%, 264-514 mV for 90%, and 287 -487 mV for 97% H 2 SO 4

  13. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  14. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  15. Effect of C content on the mechanical properties of solution treated as-cast ASTM F-75 alloys.

    Science.gov (United States)

    Herrera, M; Espinoza, A; Méndez, J; Castro, M; López, J; Rendón, J

    2005-07-01

    The mechanical properties of solution treated ASTM F-75 alloys with various carbon contents have been studied. Alloys cast under the same conditions were subjected to solution treatment for several periods and then their tensile properties were evaluated. In the as-cast conditions, the alloys exhibited higher strength values with increasing carbon content whereas their ductility was not significantly affected. For the solution treated alloys, the variation of the strength was characterized by a progressive increase for short treatment times until a maximum value was achieved, which was followed by a diminution in this property for longer treatment times. This behavior was more accentuated for the case of the alloys with medium carbon contents, which also exhibited the highest values of strength. Furthermore, the alloy's ductility was enhanced progressively with increasing solution treatment time. This improvement in ductility was significantly higher for the medium carbon alloys compared with the rest of the studied alloys. Thus, high and low carbon contents in solution treated ASTM F-75 alloys did not produced sufficiently high tensile properties.

  16. 40 CFR 92.5 - Reference materials.

    Science.gov (United States)

    2010-07-01

    ..., Standard Test Method for Distillation of Petroleum Products § 92.113 ASTM D 93-94, Standard Test Methods... API Gravity of Crude Petroleum and Petroleum Products (Hydrometer Method) § 92.113 ASTM D 445-94... Viscosity) § 92.113 ASTM D 613-95, Standard Test Method for Cetane Number of Diesel Fuel Oil § 92.113 ASTM D...

  17. 76 FR 62762 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line and Pressure Pipe From Japan...

    Science.gov (United States)

    2011-10-11

    ... Fahrenheit, at various American Society of Mechanical Engineers (``ASME'') code stress levels. Alloy pipes made to ASTM A-335 standard must be used if temperatures and stress levels exceed those allowed for..., or pressure pipe applications. B. Finished and unfinished oil country tubular goods (``OCTG''), if...

  18. Standard Guide for Selection of Test Methods for Interlayer Materials for Aerospace Transparent Enclosures

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This guide summarizes the standard test methods available for determining physical and mechanical characteristics of interlayer materials used in multi-ply aerospace transparent enclosures. 1.2 Interlayer materials are used to laminate glass-to-glass, glass-to-plastic, and plastic-to-plastic. Interlayer materials are basically transparent adhesives with high-quality optical properties. They can also serve as an energy absorbing medium, a fail-safe membrane to contain cockpit pressure and to prevent entry of impact debris; a strain insulator to accommodate different thermal expansion rates of members being laminated and as an adherent to prevent spalling of inner surface ply material fragments. The relative importance of an interlayer characteristic will be a function of the prime use it serves in its particular application. 1.3 This guide, as a summary of various methods in Section 2, is intended to facilitate the selection of tests that can be applied to interlayer materials. 1.4 The test methods list...

  19. Corrosion resistant properties and weldabilities of ASTM Grade 12 titanium alloy

    International Nuclear Information System (INIS)

    Tsumori, Yoshikatsu; Itoh, Hideo

    1988-01-01

    Plates, sheets, bars, wires and thinner seam-welded tubings were manufactured from large-scaled ingot of ASTM Grade 12 alloy (Ti-0.8Ni-0.3Mo). The processability of G-12 alloy has proved almost similar to that of conventional commercially pure titanium grades. It has been clarified that the G-12 alloy showed several advantageous features: Chlorides-Crevice corrosion resistance of the alloy was almost equals to G-7 and Pd0/TiO 2 coated titanium, and the maximum allowable stress was able to be designed higher than that of commercially pure titanium. This alloy has been in applications also offers where such environments as seawater, brines and moist chlorine, various oil refinery and chemical industries, and others. (author)

  20. Standard Guide for Benchmark Testing of Light Water Reactor Calculations

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This guide covers general approaches for benchmarking neutron transport calculations in light water reactor systems. A companion guide (Guide E2005) covers use of benchmark fields for testing neutron transport calculations and cross sections in well controlled environments. This guide covers experimental benchmarking of neutron fluence calculations (or calculations of other exposure parameters such as dpa) in more complex geometries relevant to reactor surveillance. Particular sections of the guide discuss: the use of well-characterized benchmark neutron fields to provide an indication of the accuracy of the calculational methods and nuclear data when applied to typical cases; and the use of plant specific measurements to indicate bias in individual plant calculations. Use of these two benchmark techniques will serve to limit plant-specific calculational uncertainty, and, when combined with analytical uncertainty estimates for the calculations, will provide uncertainty estimates for reactor fluences with ...

  1. Data development for ASTM E24.06.02 round robin program on instability prediction

    Science.gov (United States)

    Mccabe, D. E.

    1979-01-01

    Basis data for use in an ASTM E24.06.02 task group round robin activity was developed. Compact specimens were made of 2024-T351, 7075-T651 aluminum alloys, and 304 stainless steel. All were 12.7 mm thick and planar dimension variables incorporated were for 1T, 2T and 4T sizes. Representative raw data for each material and specimen size are contained herein. R-curves plotted in terms of delta a physical and delta a effective are plotted for each material.

  2. MATE standardization

    Science.gov (United States)

    Farmer, R. E.

    1982-11-01

    The MATE (Modular Automatic Test Equipment) program was developed to combat the proliferation of unique, expensive ATE within the Air Force. MATE incorporates a standard management approach and a standard architecture designed to implement a cradle-to-grave approach to the acquisition of ATE and to significantly reduce the life cycle cost of weapons systems support. These standards are detailed in the MATE Guides. The MATE Guides assist both the Air Force and Industry in implementing the MATE concept, and provide the necessary tools and guidance required for successful acquisition of ATE. The guides also provide the necessary specifications for industry to build MATE-qualifiable equipment. The MATE architecture provides standards for all key interfaces of an ATE system. The MATE approach to the acquisition and management of ATE has been jointly endorsed by the commanders of Air Force Systems Command and Air Force Logistics Command as the way of doing business in the future.

  3. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking.......To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  4. 75 FR 38781 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe From Japan...

    Science.gov (United States)

    2010-07-06

    ... Fahrenheit, at various American Society of Mechanical Engineers (``ASME'') code stress levels. Alloy pipes made to ASTM A-335 standard must be used if temperatures and stress levels exceed those allowed for.... B. Finished and unfinished oil country tubular goods (``OCTG''), if covered by the scope of another...

  5. Analysis of standard fracture toughness test based on digital image correlation data

    Czech Academy of Sciences Publication Activity Database

    Jandejsek, Ivan; Gajdoš, Lubomír; Šperl, Martin; Vavřík, Daniel

    2017-01-01

    Roč. 182, September (2017), s. 607-620 ISSN 0013-7944 R&D Projects: GA ČR(CZ) GA15-07210S; GA TA ČR(CZ) TE02000162 Keywords : DIC * full-field measurement * J-integral * CTOD * ASTM standard Subject RIV: JL - Materials Fatigue, Friction Mechanics OBOR OECD: Audio engineering, reliability analysis Impact factor: 2.151, year: 2016 http://www.sciencedirect.com/science/article/pii/S0013794417305799

  6. Assessment of wrought ASTM F1058 cobalt alloy properties for permanent surgical implants.

    Science.gov (United States)

    Clerc, C O; Jedwab, M R; Mayer, D W; Thompson, P J; Stinson, J S

    1997-01-01

    The behavior of the ASTM F1058 wrought cobalt-chromium-nickel-molybdenum-iron alloy (commonly referred to as Elgiloy or Phynox) is evaluated in terms of mechanical properties, magnetic resonance imaging, corrosion resistance, and biocompatibility. The data found in the literature, the experimental corrosion and biocompatibility results presented in this article, and its long track record as an implant material demonstrate that the cobalt superalloy is an appropriate material for permanent surgical implants that require high yield strength and fatigue resistance combined with high elastic modulus, and that it can be safely imaged with magnetic resonance.

  7. Glove powder's carrying capacity for latex protein: analysis using the ASTM ELISA test.

    Science.gov (United States)

    Beezhold, D; Horton, K; Hickey, V; Daddona, J; Kostyal, D

    2003-01-01

    Glove donning powders carry latex proteins and disperse them into the workplace environment. We have used the ASTM D6499 ELISA to quantify the amount of latex antigen bound to and carried by glove powders. We could differentiate between a small amount of protein actually bound to the powders and a larger amount carried by the powder. Enhanced binding of a major allergen, Hev b 5, to the starch powders was demonstrated by Western blot. The D6499 ELISA is able to measure total latex antigen, soluble and powder bound, simultaneously without the need to centrifuge the samples.

  8. Standard guide for application of radiation monitors to the control and physical security of special nuclear material

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This guide briefly describes the state-of-the-art of radiation monitors for detecting special nuclear material (SNM) (see 3.1.11) in order to establish the context in which to write performance standards for the monitors. This guide extracts information from technical documentation to provide information for selecting, calibrating, testing, and operating such radiation monitors when they are used for the control and protection of SNM. This guide offers an unobtrusive means of searching pedestrians, packages, and motor vehicles for concealed SNM as one part of a nuclear material control or security plan for nuclear materials. The radiation monitors can provide an efficient, sensitive, and reliable means of detecting the theft of small quantities of SNM while maintaining a low likelihood of nuisance alarms. 1.2 Dependable operation of SNM radiation monitors rests on selecting appropriate monitors for the task, operating them in a hospitable environment, and conducting an effective program to test, calibrat...

  9. Evaluation of a Standardized Program for Training Practicing Anesthesiologists in Ultrasound-Guided Regional Anesthesia Skills.

    Science.gov (United States)

    Mariano, Edward R; Harrison, T Kyle; Kim, T Edward; Kan, Jack; Shum, Cynthia; Gaba, David M; Ganaway, Toni; Kou, Alex; Udani, Ankeet D; Howard, Steven K

    2015-10-01

    Practicing anesthesiologists have generally not received formal training in ultrasound-guided perineural catheter insertion. We designed this study to determine the efficacy of a standardized teaching program in this population. Anesthesiologists in practice for 10 years or more were recruited and enrolled to participate in a 1-day program: lectures and live-model ultrasound scanning (morning) and faculty-led iterative practice and mannequin-based simulation (afternoon). Participants were assessed and recorded while performing ultrasound-guided perineural catheter insertion at baseline, at midday (interval), and after the program (final). Videos were scored by 2 blinded reviewers using a composite tool and global rating scale. Participants were surveyed every 3 months for 1 year to report the number of procedures, efficacy of teaching methods, and implementation obstacles. Thirty-two participants were enrolled and completed the program; 31 of 32 (97%) completed the 1-year follow-up. Final scores [median (10th-90th percentiles)] were 21.5 (14.5-28.0) of 30 points compared to 14.0 (9.0-20.0) at interval (P < .001 versus final) and 12.0 (8.5-17.5) at baseline (P < .001 versus final), with no difference between interval and baseline. The global rating scale showed an identical pattern. Twelve of 26 participants without previous experience performed at least 1 perineural catheter insertion after training (P < .001). However, there were no differences in the monthly average number of procedures or complications after the course when compared to baseline. Practicing anesthesiologists without previous training in ultrasound-guided regional anesthesia can acquire perineural catheter insertion skills after a 1-day standardized course, but changing clinical practice remains a challenge. © 2015 by the American Institute of Ultrasound in Medicine.

  10. Agile practice guide

    CERN Document Server

    2017-01-01

    Agile Practice Guide – First Edition has been developed as a resource to understand, evaluate, and use agile and hybrid agile approaches. This practice guide provides guidance on when, where, and how to apply agile approaches and provides practical tools for practitioners and organizations wanting to increase agility. This practice guide is aligned with other PMI standards, including A Guide to the Project Management Body of Knowledge (PMBOK® Guide) – Sixth Edition, and was developed as the result of collaboration between the Project Management Institute and the Agile Alliance.

  11. Effects of Spray Mixtures on Droplet Size Under Aerial Application Conditions and Implications on Drift

    Science.gov (United States)

    2010-01-01

    Liquid Drop Size Characteristics in a Spray Using Optical Nonimaging Light‐Scattering Instruments (ASTM Standards, 2003). The most common term used to...using optical nonimaging light‐scattering instruments. West Conshohocken, Pa.: ASTM Intl. ASTM Standards. 2004. E 1620. Standard terminology relating

  12. Determination of ASTM 1016 structural welded joints fracture toughness through J integral

    International Nuclear Information System (INIS)

    Martins, Geraldo de Paula; Villela, Jefferson Jose; Terra, Jose Lucio; Rabello, Emerson Giovani; Martins, Geraldo Antonio Scoralick; Carneiro, Jose Rubens Goncalves

    2009-01-01

    Fracture toughness is an important parameter for studies of materials behavior in nuclear and conventional industry. Crack propagation resistance is, in general, evaluate using one of the fracture mechanics parameters K IC , for the case of the materials that exhibits a linear elastic behavior, the CTOD (crack tip opening displacement) and J IC , the critical value of J Integral, for the case of materials with elastic-plastic behavior. On this work the fracture mechanics parameters of the ASTM 1016 structural steel welded joints were obtained, using the J Integral. Charpy V tests at several temperatures were also obtained, with the purpose to obtain the curves of ductile-brittle of the regions of the welded joints: Base Metal, (MB), and Melted Zone (MZ). The joints were welded by Gas Metal Arc Welding (GMAW) with V bevel for evaluation the MZ toughness properties. The tests were accomplished at temperatures varying from -100 deg C to 100 deg C using the technical of compliance variation for J IC determination, the critical value that defines the initial stable crack growth, that applies to brittle and ductile materials. The J Integral alternative specimens has square cross section 10mmX10mm, according ASTM E 1820, with notch localized respectively at the BM and MZ. After the tests, the specimens fractured were analyzed in a scanning microscopic electronic (SME) for verification of the fracture surface. The fractography of the specimens at elevated temperatures presented dimples at the region of stable crack growth, characteristic of ductile fracture. The results of J Integral and Charpy V presented a good correlation between these two parameters. From these correlations it can be concluded that in some applications, the use Charpy V energy to infer fracture toughness can be substitute the Integral J tests. (author)

  13. Application of ASTM E-1559 Apparatus to Study H2O Desorption

    Science.gov (United States)

    Woronowicz, Michael; Perry, Radford, III; Meadows, George A.

    2015-01-01

    The NASA James Webb Space Telescope project identified a need to measure water vapor desorption from cryogenic surfaces in order to validate predictions of spacecraft design performance. A review of available scientific literature indicated no such measurements had been reported below 131 K. Contamination control personnel at NASA Goddard Space Flight Center recognized the possibility they readily possessed the means to collect these measurements at lower temperatures using an existing apparatus commonly employed for making outgassing observations. This presentation will relate how the ASTM E-1559 Molekit apparatus was used without physical modification to measure water vapor sublimation down to 120 K and compare this data to existing equilibrium vapor pressure models.

  14. Influence of Chromium-Cobalt-Molybdenum Alloy (ASTM F75 on Bone Ingrowth in an Experimental Animal Model

    Directory of Open Access Journals (Sweden)

    Jésica Zuchuat

    2017-12-01

    Full Text Available Cr-Co-Mo (ASTM F75 alloy has been used in the medical environment, but its use as a rigid barrier membrane for supporting bone augmentation therapies has not been extensively investigated. In the present study, Cr-Co-Mo membranes of different heights were placed in New Zealand white, male rabbit tibiae to assess the quality and volume of new bone formation, without the use of additional factors. Animals were euthanized at 20, 30, 40, and 60 days. Bone formation was observed in all of the cases, although the tibiae implanted with the standard membranes reached an augmentation of bone volume that agreed with the density values over the timecourse. In all cases, plasmatic exudate was found under the membrane and in contact with the new bone. Histological analysis indicated the presence of a large number of chondroblasts adjacent to the inner membrane surface in the first stages, and osteoblasts and osteocytes were observed under them. The bone formation was appositional. The Cr-Co-Mo alloy provides a scaffold with an adequate microenvironment for vertical bone volume augmentation, and the physical dimensions and disposition of the membrane itself influence the new bone formation.

  15. Influence of Chromium-Cobalt-Molybdenum Alloy (ASTM F75) on Bone Ingrowth in an Experimental Animal Model.

    Science.gov (United States)

    Zuchuat, Jésica; Berli, Marcelo; Maldonado, Ysaí; Decco, Oscar

    2017-12-26

    Cr-Co-Mo (ASTM F75) alloy has been used in the medical environment, but its use as a rigid barrier membrane for supporting bone augmentation therapies has not been extensively investigated. In the present study, Cr-Co-Mo membranes of different heights were placed in New Zealand white, male rabbit tibiae to assess the quality and volume of new bone formation, without the use of additional factors. Animals were euthanized at 20, 30, 40, and 60 days. Bone formation was observed in all of the cases, although the tibiae implanted with the standard membranes reached an augmentation of bone volume that agreed with the density values over the timecourse. In all cases, plasmatic exudate was found under the membrane and in contact with the new bone. Histological analysis indicated the presence of a large number of chondroblasts adjacent to the inner membrane surface in the first stages, and osteoblasts and osteocytes were observed under them. The bone formation was appositional. The Cr-Co-Mo alloy provides a scaffold with an adequate microenvironment for vertical bone volume augmentation, and the physical dimensions and disposition of the membrane itself influence the new bone formation.

  16. Weldability examination of ASTM A 240 S41500 martensitic stainless steel by thermal cycles simulation testings

    Directory of Open Access Journals (Sweden)

    Alberto Velázquez-del Rosario

    2015-07-01

    Full Text Available The weldability assets of ASTM A 240 S41500 (ASTM A 240/A 240M martensitic stainless steel are presented through the study of the effects of single and double thermal weld cycles on mechanical properties and microstructure of base metal (BM and the artificial heat affected zone (HAZ created by thermal weld simulations. For single cycles, separate peak temperatures of 1000 ºC/12 s and 1350 ºC/12 s (cooling times: 12 s in both cases were evaluated, whilst two combinations of peak temperatures: (1350 ºC/5 s + 1000 ºC/5 s ºC and (1350 ºC/12 s + 1000 ºC/12 s ºC (cooling times: 5 s and 12 s, were applied for double cycles. Post weld heat treatment (PWHT with short and long holding times were applied and Vickers hardness, impact toughness and metallographic examinations were used in order to assess mechanical and metallographic properties in the as-simulated (no heat treated and postweld heat treated conditions. Best properties of the welded joint for double thermal weld cycles with long holding times were reached, which reveals the good weldability and applicability of the tested material in post weld heat treated conditions.

  17. Estimation of improved productivity based on materials substitution in high temperature applications. Use of alloy ASTM A-335 P91

    International Nuclear Information System (INIS)

    Serna, J A; Afanador, W

    2001-01-01

    In ECOPETROL-ICP was carried out an evaluation of the mechanical and micro structural properties of modified 9 Cr-1 Mo alloy, ASTM A-335 Gr. P91, finding higher strength mechanical properties, allowable stresses and creep rupture strength, than the conventional 9 Cr-1 Mo alloy, ASTM A-335 Gr. P9, recommending the alloy P91 as substitute tube material in the radiation zone of the Visbreaking heater of Cartagena's refinery (furnace in revamping process). The results obtained permit a thickness reduction of radiation tubes of material P91 close to 25% and increase the internal volume tube over up 8%, which is a parameter to consider in improving productivity and efficiency process. Also would be obtained a significant savings cost in the material among 5 and 10%. Additionally, expectations of both design and remaining useful life would be seen extensively favored with this change of alloy

  18. The first clinical implementation of real-time image-guided adaptive radiotherapy using a standard linear accelerator.

    Science.gov (United States)

    Keall, Paul J; Nguyen, Doan Trang; O'Brien, Ricky; Caillet, Vincent; Hewson, Emily; Poulsen, Per Rugaard; Bromley, Regina; Bell, Linda; Eade, Thomas; Kneebone, Andrew; Martin, Jarad; Booth, Jeremy T

    2018-04-01

    Until now, real-time image guided adaptive radiation therapy (IGART) has been the domain of dedicated cancer radiotherapy systems. The purpose of this study was to clinically implement and investigate real-time IGART using a standard linear accelerator. We developed and implemented two real-time technologies for standard linear accelerators: (1) Kilovoltage Intrafraction Monitoring (KIM) that finds the target and (2) multileaf collimator (MLC) tracking that aligns the radiation beam to the target. Eight prostate SABR patients were treated with this real-time IGART technology. The feasibility, geometric accuracy and the dosimetric fidelity were measured. Thirty-nine out of forty fractions with real-time IGART were successful (95% confidence interval 87-100%). The geometric accuracy of the KIM system was -0.1 ± 0.4, 0.2 ± 0.2 and -0.1 ± 0.6 mm in the LR, SI and AP directions, respectively. The dose reconstruction showed that real-time IGART more closely reproduced the planned dose than that without IGART. For the largest motion fraction, with real-time IGART 100% of the CTV received the prescribed dose; without real-time IGART only 95% of the CTV would have received the prescribed dose. The clinical implementation of real-time image-guided adaptive radiotherapy on a standard linear accelerator using KIM and MLC tracking is feasible. This achievement paves the way for real-time IGART to be a mainstream treatment option. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Mechanical behaviour of Astm A 297 grade Hp joints welded using different processes

    International Nuclear Information System (INIS)

    Emygdio, Paulo Roberto Oliveira; Zeemann, Annelise; Almeida, Luiz Henrique de

    1996-01-01

    The influence of different arc welding processes on mechanical behaviour was studied for cast heat resistant stainless steel welded joints, in the as welded conditions. ASTM A 297 grade HP with niobium and niobium/titanium additions were welded following three different welding procedures, using shielded metal arc welding gas tungsten arc welding and plasma arc welding, in six welded joints. The welded joint mechanical behaviour was evaluated by ambient temperature and 870 deg C tensile tests; and creep tests at 900 deg C and 50 MPa. Mechanical test results showed that the welding procedure qualification following welding codes is not suitable for high temperature service applications. (author)

  20. 78 FR 64475 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe (Over 41/2

    Science.gov (United States)

    2013-10-29

    ... stress levels. Alloy pipes made to ASTM A-335 standard must be used if temperatures and stress levels..., or pressure pipe applications. B. Finished and unfinished oil country tubular goods (OCTG), if covered by the scope of another antidumping duty order from the same country. If not covered by such an...

  1. 40 CFR 94.5 - Reference materials.

    Science.gov (United States)

    2010-07-01

    ... for Distillation of Petroleum Products at Atmospheric Pressure 94.108 ASTM D 93-02, Standard Test... Method for API Gravity of Crude Petroleum and Petroleum Products (Hydrometer Method) 94.108 ASTM D 445-01... Viscosity) 94.108 ASTM D 613-01, Standard Test Method for Cetane Number of Diesel Fuel Oil 94.108 ASTM D...

  2. Effects of the normalizing time and temperature on the impact properties of ASTM A-516 grade 70 steel

    International Nuclear Information System (INIS)

    Carneiro, T.; Cescon, T.

    1982-01-01

    The influence of normalizing time and temperature, as well as the plate thickness, on the impact properties of ASTM A-516 grade 70 steel, is studied. Results show that different normalizing conditions may lead to equivalent microstructure with different impact properties. Normalizing conditions that cause low cooling rate in the critical zone exhibit banded microstructure with inferior impact properties. (Author) [pt

  3. IAEA Safety Standards

    International Nuclear Information System (INIS)

    2016-09-01

    The IAEA Safety Standards Series comprises publications of a regulatory nature covering nuclear safety, radiation protection, radioactive waste management, the transport of radioactive material, the safety of nuclear fuel cycle facilities and management systems. These publications are issued under the terms of Article III of the IAEA’s Statute, which authorizes the IAEA to establish “standards of safety for protection of health and minimization of danger to life and property”. Safety standards are categorized into: • Safety Fundamentals, stating the basic objective, concepts and principles of safety; • Safety Requirements, establishing the requirements that must be fulfilled to ensure safety; and • Safety Guides, recommending measures for complying with these requirements for safety. For numbering purposes, the IAEA Safety Standards Series is subdivided into General Safety Requirements and General Safety Guides (GSR and GSG), which are applicable to all types of facilities and activities, and Specific Safety Requirements and Specific Safety Guides (SSR and SSG), which are for application in particular thematic areas. This booklet lists all current IAEA Safety Standards, including those forthcoming

  4. Advancements in internationally accepted standards for radiation processing

    International Nuclear Information System (INIS)

    Farrar, H. IV; Derr, D.D.; Vehar, D.W.

    1993-01-01

    Subcommittees of the American Society for Testing and Materials (ASTM) are developing standards on various aspects of radiation processing. Nine standards on how to select and calibrate dosimeters, where to put them, how many to use, and how to use individual types of dosimeter systems have been published. The group is also developing standards on how to use gamma, electron beam, and X-ray facilities for radiation processing, and a standard on how to treat dose uncertainties. Efforts are underway to promote inclusion of these standards into procedures now being developed by government agencies and by international groups such as the United Nations' International Consultative Group on Food Irradiation (ICGFI) in order to harmonize regulations and help avoid trade barriers. Standards on good irradiation practices for meat and poultry and for fresh fruits, and for the irradiation of seafood and spices have been developed. These food-related standards are based on practices previously published by ICGFI. Standards for determining doses for radiation hardness testing of electronics have been developed. Standards on the Fricke and TLD dosimetry systems are equally useful in other radiation processing applications. (Author)

  5. Standard guide for drying behavior of spent nuclear fuel

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This guide is organized to discuss the three major components of significance in the drying behavior of spent nuclear fuel: evaluating the need for drying, drying spent nuclear fuel, and confirmation of adequate dryness. 1.1.1 The guide addresses drying methods and their limitations in drying spent nuclear fuels that have been in storage at water pools. The guide discusses sources and forms of water that remain in SNF, its container, or both, after the drying process and discusses the importance and potential effects they may have on fuel integrity, and container materials. The effects of residual water are discussed mechanistically as a function of the container thermal and radiological environment to provide guidance on situations that may require extraordinary drying methods, specialized handling, or other treatments. 1.1.2 The basic issue in drying is to determine how dry the SNF must be in order to prevent issues with fuel retrievability, container pressurization, or container corrosion. Adequate d...

  6. Removal of Non-metallic Inclusions from Nickel Base Superalloys by Electromagnetic Levitation Melting in a Slag

    Science.gov (United States)

    Manjili, Mohsen Hajipour; Halali, Mohammad

    2018-02-01

    Samples of INCONEL 718 were levitated and melted in a slag by the application of an electromagnetic field. The effects of temperature, time, and slag composition on the inclusion content of the samples were studied thoroughly. Samples were compared with the original alloy to study the effect of the process on inclusions. Size, shape, and chemical composition of remaining non-metallic inclusions were investigated. The samples were prepared by Standard Guide for Preparing and Evaluating Specimens for Automatic Inclusion Assessment of Steel (ASTM E 768-99) method and the results were reported by means of the Standard Test Methods for Determining the Inclusion Content of Steel (ASTM E 45-97). Results indicated that by increasing temperature and processing time, greater level of cleanliness could be achieved, and numbers and size of the remaining inclusions decreased significantly. It was also observed that increasing calcium fluoride content of the slag helped reduce inclusion content.

  7. Measurement uncertainty. A practical guide for Secondary Standards Dosimetry Laboratories

    International Nuclear Information System (INIS)

    2008-05-01

    necessary that they conform to given safety and performance criteria. The demonstration of the competence of calibration laboratories is achieved through comparisons and the establishment of a quality system following the International Organization for Standardization (ISO) Guide 17025. One of the requirements of the quality system of a calibration laboratory is the assessment of the measurement uncertainty for all its calibration services. General guidance on the estimation of measurement uncertainty was published by ISO in 1995. However, that document addresses all calibration and testing laboratories and not specifically dosimetry calibration laboratories. To provide SSDLs of the IAEA/WHO Network with a practical guide on the assessment of the measurement uncertainty, two consultants meetings were held at IAEA Headquarters on 26-30 April, 2004 and 19-23 September 2005. The present publication was prepared during these meetings. It is addressed to scientists working in calibration laboratories and to physicists involved in radiation dosimetry measurement

  8. Standard recommended practice for examination of fuel element cladding including the determination of the mechanical properties

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Guidelines are provided for the post-irradiation examination of fuel cladding and to achieve better correlation and interpretation of the data in the field of radiation effects. The recommended practice is applicable to metal cladding of all types of fuel elements. The tests cited are suitable for determining mechanical properties of the fuel elements cladding. Various ASTM standards and test methods are cited

  9. Standardization Efforts for Mechanical Testing and Design of Advanced Ceramic Materials and Components

    Science.gov (United States)

    Salem, Jonathan A.; Jenkins, Michael G.

    2003-01-01

    Advanced aerospace systems occasionally require the use of very brittle materials such as sapphire and ultra-high temperature ceramics. Although great progress has been made in the development of methods and standards for machining, testing and design of component from these materials, additional development and dissemination of standard practices is needed. ASTM Committee C28 on Advanced Ceramics and ISO TC 206 have taken a lead role in the standardization of testing for ceramics, and recent efforts and needs in standards development by Committee C28 on Advanced Ceramics will be summarized. In some cases, the engineers, etc. involved are unaware of the latest developments, and traditional approaches applicable to other material systems are applied. Two examples of flight hardware failures that might have been prevented via education and standardization will be presented.

  10. Biodiesel Fuel Quality and the ASTM Standard

    Science.gov (United States)

    Biodiesel is usually produced from vegetable oils, animal fats and used cooking oils with alternative feedstocks such as algae receiving increasing interest. The transesterification reaction which produces biodiesel also produces glycerol and proceeds stepwise via mono- and diacylglycerol intermedia...

  11. Standard Guide for Identification of Fiber-Reinforced Polymer-Matrix Composite Materials in Databases

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This guide establishes essential and desirable data elements for fiber-reinforced composite materials for two purposes: to establish the material identification component of data-reporting requirements for test reporting and to provide information for the design of material property databases. 1.1.1 This guide is the first part of a two-part modular approach. The first part serves to identify the material and the second part serves to describe testing procedures and variables and to record results. 1.1.2 For mechanical testing, the related document is Guide E 1434. The interaction of this guide with Guide E 1434 is emphasized by the common numbering of data elements. Data Elements A1 through G13 are included in this guide, and numbering of data elements in Guide E 1434 begins with H1 for the next data element block. This guide is most commonly used in combination with a guide for reporting the test procedures and results such as Guide E 1434. 1.2 These guidelines are specific to fiber-reinforced polyme...

  12. The Higgs hunter's guide

    CERN Document Server

    Gunion, John F; Haber, Howard E; Kane, Gordon L

    1989-01-01

    The Higgs Hunter's Guide is a definitive and comprehensive guide to the physics of Higgs bosons. In particular, it discusses the extended Higgs sectors required by those recent theoretical approaches that go beyond the Standard Model, including supersymmetry and superstring-inspired models.

  13. Regulations and guides for nuclear power plants

    International Nuclear Information System (INIS)

    1984-01-01

    The purpose of the present Guide is to provide information, guidance and recommendations to assist the regulatory body of a Member State in establishing its own regulations and guides. It discusses the purpose, the method and procedure of establishment, and the content and legal status of these documents, and it explains how to use the Codes of Practice and Safety Guides issued by the IAEA under the Nuclear Safety Standards (NUSS) programme. Certain aspects of how to use other international standards and appropriate regulations and guides from other countries are discussed

  14. An isotope-dilution standard GC/MS/MS method for steroid hormones in water

    Science.gov (United States)

    Foreman, William T.; Gray, James L.; ReVello, Rhiannon C.; Lindley, Chris E.; Losche, Scott A.

    2013-01-01

    An isotope-dilution quantification method was developed for 20 natural and synthetic steroid hormones and additional compounds in filtered and unfiltered water. Deuterium- or carbon-13-labeled isotope-dilution standards (IDSs) are added to the water sample, which is passed through an octadecylsilyl solid-phase extraction (SPE) disk. Following extract cleanup using Florisil SPE, method compounds are converted to trimethylsilyl derivatives and analyzed by gas chromatography with tandem mass spectrometry. Validation matrices included reagent water, wastewater-affected surface water, and primary (no biological treatment) and secondary wastewater effluent. Overall method recovery for all analytes in these matrices averaged 100%; with overall relative standard deviation of 28%. Mean recoveries of the 20 individual analytes for spiked reagent-water samples prepared along with field samples analyzed in 2009–2010 ranged from 84–104%, with relative standard deviations of 6–36%. Detection levels estimated using ASTM International’s D6091–07 procedure range from 0.4 to 4 ng/L for 17 analytes. Higher censoring levels of 100 ng/L for bisphenol A and 200 ng/L for cholesterol and 3-beta-coprostanol are used to prevent bias and false positives associated with the presence of these analytes in blanks. Absolute method recoveries of the IDSs provide sample-specific performance information and guide data reporting. Careful selection of labeled compounds for use as IDSs is important because both inexact IDS-analyte matches and deuterium label loss affect an IDS’s ability to emulate analyte performance. Six IDS compounds initially tested and applied in this method exhibited deuterium loss and are not used in the final method.

  15. Collection Efficiencies of Various Airborne Spray Flux Samplers Used in Aerial Application Research

    Science.gov (United States)

    2008-01-01

    provided by ASTM Standard E1260: Standard Test Method for Determining Liquid Drop Size Characteristics in a Spray Using Optical Nonimaging Light...Size Characteristics in a Spray Using Optical Nonimaging Light-Scattering Instruments,” Annual Book of ASTM Stan- dards, ASTM International, West

  16. Final Report, Volume 4, The Development of Qualification Standards for Cast Super Duplex Stainless Steel (2507 Wrought Equivalent)

    Energy Technology Data Exchange (ETDEWEB)

    Hariharan, Vasudevan; Lundin, Carl, W.

    2005-09-30

    The objective of the program is to determine the suitability of ASTM A923 Standard Test methods for Detecting Detrimental Intermetallic Phase in Wrought Duplex Austenitic-Ferritic Stainless Steels for 25 Cr Cast Super Duplex Stainless Steels (ASTM A890-5A). Different tests were carried out on the materials procured from various steel foundries as stated in the ASTM A923. The foundries were designated as Foundry A, B, C and D. All the materials were foundry solution annealed. Materials from Foundry D were solution heat treated at The University of Tennessee also and then they were subjected to heat treatment schedule which was derived from the testing of wrought DSS to establish the A923 specification. This was possible because the material from the same heat was sufficient for conducting the full scope of heat treatment. This was done prior to carrying out various other tests. Charpy samples were machined. The Ferrite content was measured in all the Charpy samples using Feritscope® and ASTM E562 Manual Point Count Method. After the ferrite content was measured the samples were sent to AMC-Vulcan, Inc. in Alabama to conduct the Charpy impact test based on ASTM A923 Test Method B. This was followed by etch testing and corrosion analysis based on ASTM A923 Test Methods A and C respectively at University of Tennessee. Hardness testing using Rockwell B and C was also carried out on these samples. A correlation was derived between all the three test methods and the best method for evaluating the presence of intermetallic in the material was determined. The ferrite content was correlated with the toughness values. Microstructural analysis was carried out on the etch test samples using Scanning Electron Microscopy in order to determine if intermetallic phases were present. The fracture surfaces from Charpy test specimens were also observed under SEM in order to determine the presence of any cracks and whether it was a brittle or a ductile fracture. A correlation was

  17. Standard classification of uranium resources-an illustrative example

    International Nuclear Information System (INIS)

    Krishna, P.M.; Babitzke, H.R.; Curry, D.; Masters, C.D.; McCammon, R.B.; Noble, R.B.; Rodriguez, J.A.; Schanz, J.J.; Schreiber, H.W.

    1983-01-01

    An example illustrates the use of ASTM Standard E901-82, Classification System for Uranium Resources. The example demonstrates the dynamic nature of the process of classification and attests to the necessity of addressing both the aggregate needs of broad-scale resource planning and the specific needs of individual property evaluation. Problems that remain in fixing the classification of a given uranium resource include the uncertainty in estimating the quantity of undiscovered resources and resolving the differences that may exist in deciding when the drill-hole spacing is adequate to determine the tonnage and grade of discovered resources

  18. 46 CFR 175.600 - Incorporation by reference.

    Science.gov (United States)

    2010-10-01

    ... Vessels Under 61 Meters (200 feet) in Length, 1983 (“ABS Steel Vessel Rules (Meters)”) 177.300. Rules..., Standard Practice for Operating Salt Spray (Fog) Apparatus (“ASTM B 117”) 175.400. ASTM B 122/B 122M-95... (“ASTM D 93”) 175.400. ASTM D 635-97, Standard test Method for Rate of Burning and or Extent and Time of...

  19. standards used for quality control of nuclear fuels

    International Nuclear Information System (INIS)

    Guereli, L; Can, S.

    1997-01-01

    Nuclear fuels and fuel materials are subject to stringent restrictions as to their quality. The standards and regulations that apply vary according to reactor type and country and the standards are stated in the quality assurance documents. The concept of quality assurance has altered the conventional quality control tests and procedures, defining which control tests are to be applied and how. Although most of the tests and measurements allow the determination of tolerances to be decided according to the agreement between the buyer and the seller, exacting procedures apply to which instruments and equipment are used for these tests and measurements, how these instruments are standardized.Detailed explanations of test methods and their documentation is a requirement in all standards. The purpose of this work is to study which standards, tests and measurements apply to the nuclear fuel production. Only the standards that apply to various stages of the nuclear fuel production (powder preparation, pellet production, fuel element and fuel assembly fabrication) are reviewed. Process and documentation control, design and licensing requirements and the frequency of inspections are quality assurance subjects. Some ASTM standards are given as examples

  20. Standardization Documents

    Science.gov (United States)

    2011-08-01

    Specifications and Standards; Guide Specifications; CIDs; and NGSs . Learn. Perform. Succeed. STANDARDIZATION DOCUMENTS Federal Specifications Commercial...national or international standardization document developed by a private sector association, organization, or technical society that plans ...Maintain lessons learned • Examples: Guidance for application of a technology; Lists of options Learn. Perform. Succeed. DEFENSE HANDBOOK

  1. Standard Guide for Environmental Monitoring Plans for Decommissioning of Nuclear Facilities

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This guide covers the development or assessment of environmental monitoring plans for decommissioning nuclear facilities. This guide addresses: (1) development of an environmental baseline prior to commencement of decommissioning activities; (2) determination of release paths from site activities and their associated exposure pathways in the environment; and (3) selection of appropriate sampling locations and media to ensure that all exposure pathways in the environment are monitored appropriately. This guide also addresses the interfaces between the environmental monitoring plan and other planning documents for site decommissioning, such as radiation protection, site characterization, and waste management plans, and federal, state, and local environmental protection laws and guidance. This guide is applicable up to the point of completing D&D activities and the reuse of the facility or area for other purposes.

  2. Standard guide for in-plant performance evaluation of automatic pedestrian SNM monitors

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This guide is affiliated with Guide C1112 on special nuclear material (SNM) monitors, Guide C1169 on laboratory performance evaluation, and Guide C1189 on calibrating pedestrian SNM monitors. This guide to in-plant performance evaluation is a comparatively rapid way to verify whether a pedestrian SNM monitor performs as expected for detecting SNM or SNM-like test sources. 1.1.1 In-plant performance evaluation should not be confused with the simple daily functional test recommended in Guide C1112. In-plant performance evaluation takes place less often than daily tests, usually at intervals ranging from weekly to once every three months. In-plant evaluations are also more extensive than daily tests and may examine both a monitor's nuisance alarm record and its detection sensitivity for a particular SNM or alternative test source. 1.1.2 In-plant performance evaluation also should not be confused with laboratory performance evaluation. In-plant evaluation is comparatively rapid, takes place in the monitor...

  3. Evaluation of Suitability of Non-Standardized Test Block for Ultrasonic Testing

    International Nuclear Information System (INIS)

    Kwon, Ho Young; Lim, Jong Ho; Kang, Sei Sun

    2000-01-01

    Standard Test Block(STB) for UT(Ultrasonic Testing) is a block approved by authoritative for material, shape and quality. STB is used for characteristic tests, sensitivity calibration and control of the time base range of UT inspection devices. The material, size and chemical components of STB should be strictly controlled to meet the related standards such as ASTM and JIS because it has an effect upon sensitivity, resolution and reproductivity of UT. The STBs which are not approved are sometimes used because the qualified STBs are very expensive. So, the purpose of this study is to survey the characteristics, quality and usability of Non-Standardized Test Blocks. Non-Standardized Test Blocks did not meet the standard requirements in size or chemical components, and ultrasonic characteristics. Therefore if the Non-Standardized Test Blocks are used without being tested, it's likely to cause errors in detecting the location and measuring the size of the defects

  4. Human factors guides

    International Nuclear Information System (INIS)

    Penington, J.

    1995-10-01

    This document presents human factors guides, which have been developed in order to provide licensees of the AECB with advice as to how to address human factors issues within the design and assessment process. This documents presents the results of a three part study undertaken to develop three guides which are enclosed in this document as Parts B, C and D. As part of the study human factors standards, guidelines, handbooks and other texts were researched, to define those which would be most useful to the users of the guides and for the production of the guides themselves. Detailed specifications were then produced to outline the proposed contents and format of the three guides. (author). 100 refs., 3 tabs., 11 figs

  5. Human factors guides

    Energy Technology Data Exchange (ETDEWEB)

    Penington, J [PHF Services Inc., (Canada)

    1995-10-01

    This document presents human factors guides, which have been developed in order to provide licensees of the AECB with advice as to how to address human factors issues within the design and assessment process. This documents presents the results of a three part study undertaken to develop three guides which are enclosed in this document as Parts B, C and D. As part of the study human factors standards, guidelines, handbooks and other texts were researched, to define those which would be most useful to the users of the guides and for the production of the guides themselves. Detailed specifications were then produced to outline the proposed contents and format of the three guides. (author). 100 refs., 3 tabs., 11 figs.

  6. [Usefulness of the guide of standards for the duration of processes of transient work disability published by Insalud for the attending physician].

    Science.gov (United States)

    Berriochoa Martínez de Pisón, C; Sanz Carabaña, P; Flores Ortueta, L; Soto Fernández, S; Villagrasa Ferrer, J R

    1996-09-30

    To compare the duration average of the ten most frequent causes of unfitness for work (ILT) observed in a services company's staff, with the duration standards registered in the guide published by the Insalud. Besides, some of the factors that could influence these ten diseases duration will be analyzed. An observational, retrospective, population-based study. Sanitary district in Madrid area. Hospital Universitario de la Princesa's staff. From 1-1-93 to 31-12-94, a total of 1835 ILTs have been registered among the 2147 workers. Among the ten most frequent causes of ILT analysed, influenza, acute gastroenteritis, lumbalgia, anide sprain, lumbociatica, contusions, tonsillitis and bronchitis have a duration median included within the Insalud's references. Acute respiratory infection duration is situated out of the intervals. Depressive syndrome does not appear in the guide. It has been proved that all the previous causes have a greater incidence on women except for contusions, tonsillitis and bronchitis. Ankle sprain has a longer duration in workers over fifty years old. We consider that Insalud's standards guide should be promoted and improved in order to be used as a reference handbook by general practitioners.

  7. La puissance prescriptive des guides à Paris The prescriptive power of tour guides in Paris. Standardizing elements of tourism ?

    Directory of Open Access Journals (Sweden)

    Gwendal Simon

    2008-10-01

    Full Text Available Les « guide-interprètes » constituent des médiateurs entre les touristes et les espaces. Incarnant une présence physique en mesure d’aider les touristes en les informant sur la ville, ils opèrent comme prescripteurs de choses à voir et à faire. S’ils officient très diversement selon les touristes qu’ils accompagnent, ils exercent toujours leur pratique dans une logique de production de discours sur la ville. À Paris, la dimension muséale et patrimoniale constitue depuis longtemps le socle de l’attractivité touristique, qui continue de capitaliser sur des imaginaires et des pratiques liés à la grande ville d’Art et d’Histoire. Face à la constitution de ce référentiel dominant qui opère comme une force d’ « imposition », les guide-interprètes tentent néanmoins de décentrer le regard par des prescriptions délestées des symboles. C’est cette « tension » entre cet ensemble de références touristiques « à voir » et le souci de montrer la ville dans sa pluralité que nous analysons. Ces éléments nourrissent la réflexion actuelle sur les formes polarisées du tourisme à Paris et l’importance de la production de référents urbains plus contemporains que promeut la municipalité.Tour guides are mediators between tourists and spaces. As they embody a physical presence helping tourists and informing them about the city, they also act as prescribers, laying down what is supposed to be seen and to be done. If their recommendations depend on the tourists they travel with, they always mean to produce a discourse on the city. Paris’ museums and heritage have long since been two cornerstones of her enduring appeal. Confronted with this phenomenon, which tends to standardize the way of visiting a city, tour guides try to free their guidelines of symbolic references. This contribution focuses on the tension between must-see tourist references and the desire to show the city in all its diversity. These

  8. 40 CFR 761.19 - References.

    Science.gov (United States)

    2010-07-01

    ... Products (General Bomb Method) § 761.71(b)(2)(vi) ASTM D 240-87 Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuel by Bomb Calorimeter § 761.71(b)(2)(vi) ASTM D 482-87 Standard Test Method... in New and Used Petroleum Products (Bomb Method) § 761.71(b)(2)(vi) ASTM D 923-86 Standard Test...

  9. Experiment Design and Analysis Guide - Neutronics & Physics

    Energy Technology Data Exchange (ETDEWEB)

    Misti A Lillo

    2014-06-01

    The purpose of this guide is to provide a consistent, standardized approach to performing neutronics/physics analysis for experiments inserted into the Advanced Test Reactor (ATR). This document provides neutronics/physics analysis guidance to support experiment design and analysis needs for experiments irradiated in the ATR. This guide addresses neutronics/physics analysis in support of experiment design, experiment safety, and experiment program objectives and goals. The intent of this guide is to provide a standardized approach for performing typical neutronics/physics analyses. Deviation from this guide is allowed provided that neutronics/physics analysis details are properly documented in an analysis report.

  10. Impact of standards and certification on environmental impairment liability insurance programs

    International Nuclear Information System (INIS)

    Gulledge, W.P.

    1993-01-01

    Environmental impairment liability (EIL) insurance is available for petroleum storage tank and other environmental exposures. Recent standards and performance criteria for leak detection for underground storage tanks (USTs) and other technical standards for USTs have been both a benefit and an interference to risk-based underwriting of storage tank EIL insurance programs. Insurance underwriters and state financial responsibility program administrators are confronted with confusing information to manage these environmental risks. Standards and certification are also key issues for site assessment programs. Recent activities from ASTM and the Institute for Environmental Auditing (IEA) have addressed the need to increase the professional stature of site assessments and environmental management. Reaction and acceptance of these efforts by the users have been mixed. Ultimately, these efforts will greatly impact insurance coverage for environmental risks

  11. Moessbauer spectroscopy study on the corrosion resistance of plasma nitrided ASTM F138 stainless steel in chloride solution

    International Nuclear Information System (INIS)

    Souza, S.D. de; Olzon-Dionysio, M.; Basso, R.L.O.; Souza, S. de

    2010-01-01

    Plasma nitriding of ASTM F138 stainless steel samples has been carried out using dc glow discharge under 80% H 2 -20% N 2 gas mixture, at 673 K, and 2, 4, and 7 h time intervals, in order to investigate the influence of treatment time on the microstructure and the corrosion resistance properties. The samples were characterized by scanning electron microscopy, glancing angle X-ray diffraction and conversion electron Moessbauer spectroscopy, besides electrochemical tests in NaCl aerated solution. A modified layer of about 6 μm was observed for all the nitrided samples, independent of nitriding time. The X-ray diffraction analysis shows broad γ N phase peaks, signifying a great degree of nitrogen supersaturation. Besides γ N, the Moessbauer spectroscopy results indicated the occurrence of γ' and ε phases, as well as some other less important phases. Corrosion measurements demonstrate that the plasma nitriding time affects the corrosion resistance and the best performance is reached at 4 h treatment. It seems that the ε/γ' fraction ratio plays an important role on the resistance corrosion. Additionally, the Moessbauer spectroscopy was decisive in this study, since it was able to identify and quantify the iron phases that influence the corrosion resistance of plasma nitrided ASTM F138 samples.

  12. Good research guide, second edition

    CSIR Research Space (South Africa)

    Scholes, RJ

    2003-01-01

    Full Text Available This guide informs CSIR staff about the standards that they are expected to meet when doing research. Researchers who follow this guide will have satisfied the legal requirement for 'due diligence' in their work....

  13. Phases Evolution of an ASTM 335 steel under continuous cooling P91

    International Nuclear Information System (INIS)

    Carrizo, D.A; Danon, C.A; Ramos, C.P

    2012-01-01

    This paper studies the influence of the cooling rate on phase transformations and the resulting microstructure in continuous cooling cycles for an ASTM A335 P91 steel, under fixed austenization conditions. The CCT (Continuous Cooling Transformation) diagram of this material is reported in the literature, so the main phase fields are known. The final structure of the samples depends on the austenitic grain size and the cooling rate. The studied samples were austenized at 1050 o C for 30 minutes and then cooled at different rates between 50 o C/h and 300 o C/h. The identification and characterization of the phases was carried out by using Scanning Electron Microscopy, X-ray Diffraction and Moessbauer Spectroscopy. From the results so obtained, additions to the CCT diagram of the material are proposed, providing new information to it

  14. 30 CFR 75.1429 - Guide ropes.

    Science.gov (United States)

    2010-07-01

    ... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Hoisting and Mantrips Wire Ropes § 75.1429 Guide ropes. If guide... strength (manufacturer's published catalog strength) of the guide rope at installation shall meet the...

  15. Proposal and Evaluation of Subordinate Standard Solar Irradiance Spectra for Applications in Solar Energy Systems

    Energy Technology Data Exchange (ETDEWEB)

    Habte, Aron M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Jessen, Wilko [German Aerospace Center (DLR); Wilbert, Stefan [German Aerospace Center (DLR); Gueymard, Christian A. [Solar Consulting Services; Polo, Jesus [CIEMAT; Bian, Zeqiang [China Meteorological Administration; Driesse, Anton [Photovoltaic Performance Labs; Marzo, Aitor [University of Antofagasta; Armstrong, Peter [Masdar Institute of Science & Technology; Vignola, Frank [University of Oregon; Ramirez, Lourdes [CIEMAT

    2018-04-01

    Reference solar irradiance spectra are needed to specify key parameters of solar technologies such as photovoltaic cell efficiency, in a comparable way. The IEC 60904-3 and ASTM G173 standards present such spectra for Direct Normal Irradiance (DNI) and Global Tilted Irradiance (GTI) on a 37 degrees tilted sun-facing surface for one set of clear-sky conditions with an air mass of 1.5 and low aerosol content. The IEC/G173 standard spectra are the widely accepted references for these purposes. Hence, the authors support the future replacement of the outdated ISO 9845 spectra with the IEC spectra within the ongoing update of this ISO standard. The use of a single reference spectrum per component of irradiance is important for clarity when comparing and rating solar devices such as PV cells. However, at some locations the average spectra can differ strongly from those defined in the IEC/G173 standards due to widely different atmospheric conditions and collector tilt angles. Therefore, additional subordinate standard spectra for other atmospheric conditions and tilt angles are of interest for a rough comparison of product performance under representative field conditions, in addition to using the main standard spectrum for product certification under standard test conditions. This simplifies the product selection for solar power systems when a fully-detailed performance analysis is not feasible (e.g. small installations). Also, the effort for a detailed yield analyses can be reduced by decreasing the number of initial product options. After appropriate testing, this contribution suggests a number of additional spectra related to eight sets of atmospheric conditions and tilt angles that are currently considered within ASTM and ISO working groups. The additional spectra, called subordinate standard spectra, are motivated by significant spectral mismatches compared to the IEC/G173 spectra (up to 6.5%, for PV at 37 degrees tilt and 10-15% for CPV). These mismatches

  16. Teaching Standard English as a Second Dialect to Primary School Children in Hilo, Hawaii. Appendix B: Teacher's Guide and Lessons. Volume II of II Volumes. Final Report.

    Science.gov (United States)

    Sugai, Elaine E.; Sugano, Miyoko

    This document comprises the teacher's guide and lessons for teaching standard English to kindergarten through third grade children in Hilo, Hawaii. Sections are (1) Teacher's Guide, (2) Audio-Visual Aids, (3) Phonemic Symbol List, (4) Phonology Lesson Section, and (5) Structure Lesson Section. Appended are a short glossary of terms,…

  17. Changes of the mechanical properties of ASTM A 533 type B class 1 (JRQ) steel used in pressure vessels of nuclear power plants

    International Nuclear Information System (INIS)

    Balderrama, Juan J.; Iorio, Antonio F.

    1999-01-01

    The steels used in pressure vessels generally present a non-homogenous microstructure across the thickness of their walls due to their manufacturing process. Average thickness being between 200-250 mm also makes the problem more serious. These facts lead us to think that the variation affects not only microstructure, but also mechanical properties. For this reason the methodology for the evaluation of materials should be standardized for their use before and after radiation by means of a surveillance program which allows us to verify the conditions of the steel of the pressure vessel by using Charpy-v, tensile and fracto-mechanics specimens inside the reactor to obtain information about the condition of the pressure vessel material. In order to analyze these changes, tests were carried out using Charpy-v specimens with different orientation inside the block representing the wall thickness and the corresponding ductile-to-brittle transition curves were made for each direction. The orientations to be considered will be four in all and will be those called TL, LT, ST and LS by ASTM E 399 (1993). The conclusions reached arise from a comparative analysis of the results obtained for each orientation under study and confirm the recommendation by Standards regarding the selection of the TL orientation as the most conservative. (author)

  18. DOE standard: Integration of environment, safety, and health into facility disposition activities. Volume 1 of 2: Technical standard

    International Nuclear Information System (INIS)

    1998-05-01

    This Department of Energy (DOE) technical standard (referred to as the Standard) provides guidance for integrating and enhancing worker, public, and environmental protection during facility disposition activities. It provides environment, safety, and health (ES and H) guidance to supplement the project management requirements and associated guidelines contained within DOE O 430.1A, Life-Cycle Asset Management (LCAM), and amplified within the corresponding implementation guides. In addition, the Standard is designed to support an Integrated Safety Management System (ISMS), consistent with the guiding principles and core functions contained in DOE P 450.4, Safety Management System Policy, and discussed in DOE G 450.4-1, Integrated Safety Management System Guide. The ISMS guiding principles represent the fundamental policies that guide the safe accomplishment of work and include: (1) line management responsibility for safety; (2) clear roles and responsibilities; (3) competence commensurate with responsibilities; (4) balanced priorities; (5) identification of safety standards and requirements; (6) hazard controls tailored to work being performed; and (7) operations authorization. This Standard specifically addresses the implementation of the above ISMS principles four through seven, as applied to facility disposition activities

  19. Proposal and Evaluation of Subordinate Standard Solar Irradiance Spectra: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Habte, Aron M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Wilbert, Stefan [German Aerospace Center (DLR); Jessen, Wilko [German Aerospace Center (DLR); Gueymard, Chris [Solar Consulting Services; Polo, Jesus [CIEMAT; Bian, Zeqiang [China Meteorological Administration; Driesse, Anton [Photovoltaic Performance Labs; Marzo, Aitor [University of Antofagasta; Armstrong, Peter [Masdar Institute of Science & Technology; Vignola, Frank [University of Oregon; Ramirez, Lourdes [CIEMAT

    2018-04-12

    This paper introduces a concept for global tilted irradiance (GTI) subordinate standard spectra to supplement the current standard spectra used in solar photovoltaic applications as defined in ASTM G173 and IEC60904. The proposed subordinate standard spectra correspond to atmospheric conditions and tilt angles that depart significantly from the main standard spectrum, and they can be used to more accurately represent various local conditions. For the definition of subordinate standard spectra cases with an elevation 1.5 km above sea level, the question arises whether the air mass should be calculated including a pressure correction or not. This study focuses on the impact of air mass used in standard spectra, and it uses data from 29 locations to examine which air mass is most appropriate for GTI and direct normal irradiance (DNI) spectra. Overall, it is found that the pressure-corrected air mass of 1.5 is most appropriate for DNI spectra. For GTI, a non-pressure-corrected air mass of 1.5 was found to be more appropriate.

  20. Studies on the welding of heavy-section ASTM A542 Cl. 1 steel for large-sized pressure vessels

    International Nuclear Information System (INIS)

    Shimizu, Shigeki; Aota, Toshiichi; Kasahara, Masayuki

    1977-01-01

    ASTM A 542, Cl. 1 steel was developed and standardized recently, and is excellent in the high temperature strength and toughness as compared with conventionally used A 387, Grade 22 steel, accordingly the application to large pressure vessels is planned. This steel is a low alloy steel, and in case of large thickness, the possibility of cracking in the welded part is large. Also many times of annealing are required for the prevention of welding cracking, the relieving of residual stress, and the softening of hardened portion, but the possibility of cracking during stress-relieving annealing is large. In this study, Tekken type cracking test was carried out by coated electrode welding, and restricted cracking test was carried out by submerged arc welding of the A 542, Cl. 1 steel and A 387, Grade 22 steel, thus the welding cracking property was investigated, and the optimal welding conditions were selected. Also the test of cracking during the stress-relieving annealing of both steels was carried out, and the method of preventing the cracking was studied. The optimal conditions of stress-relieving annealing were selected, and the mechanism of the cracking was clarified. The mechanical properties of the joints welded and stress-relieved under the selected conditions were confirmed. (Kako, I.)

  1. Effect of using the double layer technique on the microstructure, microhardness and residual stress of welded ASTM A516 GR70 structural steel

    International Nuclear Information System (INIS)

    Oliveira, George Luiz Gomes de; Miranda, Helio Cordeiro de

    2010-01-01

    The aim of this work is to evaluate the effect of using the double layer technique on the microstructure, microhardness and residual stresses of welded ASTM A516 Gr70 structural steel. Samples were welded with the same welding parameters and two types of chamfers, while the samples welded using the double layer technique underwent a buttering process on their chamfer face. Residual stress measurement was accomplished through x-ray diffraction, using a mini diffractometer for measurement in field. Metallographic analysis was accomplished in the transverse section of the welded joint, using optic microscopy and scanning electron microscopy. The double layer technique showed that can be used in the welding of ASTM A516 Gr70 steel, because, besides promote a refinement and a drawing back of the CG-HAZ, it increased compressive residual stress in the whole surface of the analyzed samples.(author)

  2. Standard guide for radioactive pathway methodology for release of sites following decommissioning

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    The purpose of this guide is to provide guidance in determining site-specific conversion factors for translating between dose limits and residual radioactive contamination levels on equipment structures, and land areas. This guide is to serve as a guide to acceptable methodology for translating the yet to be determined dose limits into allowable levels of residual radioactive materials that can be left at a site following decommissioning

  3. Online purchases of an expanded range of condom sizes in comparison to current dimensional requirements allowable by US national standards.

    Science.gov (United States)

    Cecil, Michael; Warner, Lee; Siegler, Aaron J

    2013-11-01

    Across studies, 35-50% of men describe condoms as fitting poorly. Rates of condom use may be inhibited in part due to the inaccessibility of appropriately sized condoms. As regulated medical devices, condom sizes conform to national standards such as those developed by the American Society for Testing and Materials (ASTM) or international standards such as those developed by the International Organisation for Standardisation (ISO). We describe the initial online sales experience of an expanded range of condom sizes and assess uptake in relation to the current required standard dimensions of condoms. Data regarding the initial 1000 sales of an expanded range of condom sizes in the United Kingdom were collected from late 2011 through to early 2012. Ninety-five condom sizes, comprising 14 lengths (83-238mm) and 12 widths (41-69mm), were available. For the first 1000 condom six-pack units that were sold, a total of 83 of the 95 unique sizes were purchased, including all 14 lengths and 12 widths, and both the smallest and largest condoms. Initial condom purchases were made by 572 individuals from 26 countries. Only 13.4% of consumer sales were in the ASTM's allowable range of sizes. These initial sales data suggest consumer interest in an expanded choice of condom sizes that fall outside the range currently allowable by national and international standards organisations.

  4. The IAEA safety standards

    International Nuclear Information System (INIS)

    Karbassioun, Ahmad

    1995-01-01

    During the development of the NUSS standards, wide consultation was carried out with all the Member States to obtain a consensus and the programme was supervised by a Senior Advisory Group consisting of senior safety experts from 13 countries. This group of senior regulators later became what is now known as the Nuclear Safety Standards Advisory Group (NUSSAG) and comprises of senior regulatory experts from 16 countries. The standards that were developed comprise of four types of documents: safety fundamentals; codes of practice; safety guides; and safety practices. The safety fundamentals set out the basic objectives, concepts and principles for nuclear safety in nuclear power plants. The codes of practice, are of a legislative nature, and establish the general objectives that must be fulfilled to ensure adequate nuclear power plant safety. They cover five areas: governmental organization; siting, design, operation and quality assurance. The safety guides, administrative in character, recommend procedures and acceptable technical solutions to implement the codes and guides by presenting further details gained from Member States, on the application and interpretation of individual concepts in the NUSS codes and guides. In total in the NUSS series there is currently one Fundamentals document, five Codes of Practice and fifty-six Safety Guides

  5. Effect of increased fuel temperature on emissions of oxides of nitrogen from a gas turbine combustor burning ASTM jet-A fuel

    Science.gov (United States)

    Marchionna, N. R.

    1974-01-01

    An annular gas turbine combustor was tested with heated ASTM Jet-A fuel to determine the effect of increased fuel temperature on the formation of oxides of nitrogen. Fuel temperature ranged from ambient to 700 K. The NOx emission index increased at a rate of 6 percent per 100 K increase in fuel temperature.

  6. Dosimetry standards for radiation processing

    International Nuclear Information System (INIS)

    Farrar, H. IV

    1999-01-01

    For irradiation treatments to be reproducible in the laboratory and then in the commercial environment, and for products to have certified absorbed doses, standardized dosimetry techniques are needed. This need is being satisfied by standards being developed by experts from around the world under the auspices of Subcommittee E10.01 of the American Society for Testing and Materials (ASTM). In the time period since it was formed in 1984, the subcommittee has grown to 150 members from 43 countries, representing a broad cross-section of industry, government and university interests. With cooperation from other international organizations, it has taken the combined part-time effort of all these people more than 13 years to complete 24 dosimetry standards. Four are specifically for food irradiation or agricultural applications, but the majority apply to all forms of gamma, x-ray, Bremsstrahlung and electron beam radiation processing, including dosimetry for sterilization of health care products and the radiation processing of fruits, vegetables, meats, spices, processed foods, plastics, inks, medical wastes and paper. An additional 6 standards are under development. Most of the standards provide exact procedures for using individual dosimetry systems or for characterizing various types of irradiation facilities, but one covers the selection and calibration of dosimetry systems, and another covers the treatment of uncertainties. Together, this set of standards covers essentially all aspects of dosimetry for radiation processing. The first 20 of these standards have been adopted in their present form by the International Organization of Standardization (ISO), and will be published by ISO in 1999. (author)

  7. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  8. Microstructure evolution of ASTM 335 P91 steel, subjected to continuous cooling

    International Nuclear Information System (INIS)

    Carrizo, D.A; Danon, C.A; Ramos, C.P

    2012-01-01

    This paper studies the influence of the cooling rate on an isothermal phase transformations in ASTM A335 P91 steel, by the analysis of the resulting microstructure after several continuous cooling cycles under fixed austenization conditions. The CCT (Continuous Cooling Transformation) diagram of this material has already been reported in the literature, so the main phase fields are known, and they depend on the austenitic grain size and the cooling rate. Five samples were tested in a dilatometer, they were austenized and then cooled at different rates between 50 o C/h and 300 o C/h. The identification and characterization of the resulting phases was carried out by using Scanning Electron Microscopy, X-ray Diffraction and Mossbauer Spectroscopy. The obtained results allowed to add information about the presence of retained austenite and (Fe,Cr) 3 C - type carbides to the CCT diagram of the material (author)

  9. Final Report, Volume 4, The Develpoment of Qualification Standards forCast Super Duplex Stainless Steel (2507 Wrought Equivalent)

    Energy Technology Data Exchange (ETDEWEB)

    Hariharan, Vasudevan; Lundin, Carl, D.

    2005-09-30

    The objective of the program is to determine the suitability of ASTM A923 Standard Test methods for Detecting Detrimental Intermetallic Phase in Wrought Duplex Austenitic-Ferritic Stainless Steels for 25 Cr Cast Super Duplex Stainless Steels (ASTM A890-5A). Different tests were carried out on the materials procured from various steel foundries as stated in the ASTM A923. The foundries were designated as Foundry A, B, C and D. All the materials were foundry solution annealed. Materials from Foundry D were solution heat treated at The University of Tennessee also and then they were subjected to heat treatment schedule which was derived from the testing of wrought DSS to establish the A923 specification. This was possible because the material from the same heat was sufficient for conducting the full scope of heat treatment. This was done prior to carrying out various other tests. Charpy samples were machined. The Ferrite content was measured in all the Charpy samples using Feritscope{reg_sign} and ASTM E562 Manual Point Count Method. After the ferrite content was measured the samples were sent to AMC-Vulcan, Inc. in Alabama to conduct the Charpy impact test based on ASTM A923 Test Method B. This was followed by etch testing and corrosion analysis based on ASTM A923 Test Methods A and C respectively at University of Tennessee. Hardness testing using Rockwell B and C was also carried out on these samples. A correlation was derived between all the three test methods and the best method for evaluating the presence of intermetallic in the material was determined. The ferrite content was correlated with the toughness values. Microstructural analysis was carried out on the etch test samples using Scanning Electron Microscopy in order to determine if intermetallic phases were present. The fracture surfaces from Charpy test specimens were also observed under SEM in order to determine the presence of any cracks and whether it was a brittle or a ductile fracture. A correlation

  10. RestKit for iOS standard guide

    CERN Document Server

    Kalapun, Taras

    2013-01-01

    A step-by-step, example-based guide to learning how you can link your apps and web services using RestKit.This book is for iOS developers of all levels who are interested in boosting their productivity by utilizing third party libraries and who have a willingness to learn how to build RESTful apps using the RestKit framework. A basic knowledge of Objective-C is required as well as a simple understanding of how to use CoreData.

  11. Standard guide for high-resolution gamma-ray spectrometry of soil samples

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This guide covers the identification and quantitative determination of gamma-ray emitting radionuclides in soil samples by means of gamma-ray spectrometry. It is applicable to nuclides emitting gamma rays with an approximate energy range of 20 to 2000 keV. For typical gamma-ray spectrometry systems and sample types, activity levels of about 5 Bq (135 pCi) are measured easily for most nuclides, and activity levels as low as 0.1 Bq (2.7 pCi) can be measured for many nuclides. It is not applicable to radionuclides that emit no gamma rays such as the pure beta-emitting radionuclides hydrogen-3, carbon-14, strontium-90, and becquerel quantities of most transuranics. This guide does not address the in situ measurement techniques, where soil is analyzed in place without sampling. Guidance for in situ techniques can be found in Ref (1) and (2). This guide also does not discuss methods for determining lower limits of detection. Such discussions can be found in Refs (3), (4), (5), and (6). 1.2 This guide can be us...

  12. An investigation of force components in orthogonal cutting of medical grade cobalt-chromium alloy (ASTM F1537).

    Science.gov (United States)

    Baron, Szymon; Ahearne, Eamonn

    2017-04-01

    An ageing population, increased physical activity and obesity are identified as lifestyle changes that are contributing to the ongoing growth in the use of in-vivo prosthetics for total hip and knee arthroplasty. Cobalt-chromium-molybdenum (Co-Cr-Mo) alloys, due to their mechanical properties and excellent biocompatibility, qualify as a class of materials that meet the stringent functional requirements of these devices. To cost effectively assure the required dimensional and geometric tolerances, manufacturers rely on high-precision machining. However, a comprehensive literature review has shown that there has been limited research into the fundamental mechanisms in mechanical cutting of these alloys. This article reports on the determination of the basic cutting-force coefficients in orthogonal cutting of medical grade Co-Cr-Mo alloy ASTM F1537 over an extended range of cutting speeds ([Formula: see text]) and levels of undeformed chip thickness ([Formula: see text]). A detailed characterisation of the segmented chip morphology over this range is also reported, allowing for an estimation of the shear plane angle and, overall, providing a basis for macro-mechanic modelling of more complex cutting processes. The results are compared with a baseline medical grade titanium alloy, Ti-6Al-4V ASTM F136, and it is shown that the tangential and thrust-force components generated were, respectively, ≈35% and ≈84% higher, depending primarily on undeformed chip thickness but with some influence of the cutting speed.

  13. Standard guide for high-temperature static strain measurement

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1998-01-01

    1.1 This guide covers the selection and application of strain gages for the measurement of static strain up to and including the temperature range from 425 to 650°C (800 to 1200°F). This guide reflects some current state-of-the-art techniques in high temperature strain measurement, and will be expanded and updated as new technology develops. 1.2 This practice assumes that the user is familiar with the use of bonded strain gages and associated signal conditioning and instrumentation as discussed in Refs. (1) and (2). The strain measuring systems described are those that have proven effective in the temperature range of interest and were available at the time of issue of this practice. It is not the intent of this practice to limit the user to one of the gage types described nor is it the intent to specify the type of system to be used for a specific application. However, in using any strain measuring system including those described, the proposer must be able to demonstrate the capability of the proposed sy...

  14. International cooperative effort to establish dosimetry standardization for radiation processing

    International Nuclear Information System (INIS)

    Farrar, H. IV.

    1989-01-01

    Radiation processing is a rapidly developing technology with numerous applications in food treatment, sterilization, and polymer modification. The effectiveness of the process depends, however, on the proper application of dose and its measurement. These aspects are being considered by a wide group of experts from around the world who have joined together to write a comprehensive set of standards for dosimetry for radiation processing. Originally formed in 1984 to develop standards for food processing dosimetry, the group has now expanded into a full subcommittee of the American Society for Testing and Materials (ASTM), with 97 members from 19 countries. The scope of the standards now includes dosimetry for all forms of radiation processing. The group has now completed and published four standards, and is working on an additional seven. Three are specifically for food applications and the others are for all radiation applications, including food processing. Together, this set of standards will specify acceptable guidelines and methods for accomplishing the required irradiation treatment, and will be available for adoption by national regulatory agencies in their procedures and protocols. 1 tab

  15. Designing cathodic protection systems for marine structures and vehicles. ASTM special technical publication 1370

    Energy Technology Data Exchange (ETDEWEB)

    Hack, H.P. [ed.

    1999-07-01

    Cathodic protection is an important method of protecting structures and ships from the corrosive effects of seawater. Poor designs can be far more costly to implement than optimal designs, Improper design can cause overprotection, with resulting paint blistering and accelerated corrosion of some alloys, underprotection, with resultant structure corrosion, or stray current corrosion of nearby structures. The first ASTM symposium specifically aimed at cathodic protection in seawater was intended to compile all the criteria and philosophy for designing both sacrificial and impressed current cathodic protection systems for structures and vehicles in seawater. The papers which are included in this STP are significant in that they summarize the major seawater cathodic protection system design philosophies. Papers have been processed separately for inclusion on the database.

  16. 78 FR 73415 - Safety Standard for Hand-Held Infant Carriers

    Science.gov (United States)

    2013-12-06

    ... modifications to the ASTM test procedure set forth in ASTM F2050-12 so that the test produces more repeatable... skills necessary for the preparation of reports or records; and a description of the steps the agency has... the Rule on Small Business There are at least 47 firms currently known to be marketing hand- held...

  17. Standards development for fiber optic spectroscopic components for adverse environments

    Science.gov (United States)

    Saggese, Steven J.; Greenwell, Roger A.

    1994-09-01

    Optical fiber sensors are finding wider use in all types of applications involving adverse environments, including exposure to radiation. In order to effectively characterize and evaluate the performance of a fiber sensor system for a radiation environment, such as within a nuclear power plant or in a radioactive waste storage/disposal facility, it is beneficial to develop standard test procedures. Science & Engineering Associates (SEA) has developed two such procedures for the American Society for Testing and Materials (ASTM) which address the testing of optical fibers for remote Raman spectroscopic and broadband sensor applications in a steady state radiation environment.

  18. Standard guide for the selection, training and qualification of nondestructive assay (NDA) personnel

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This guide contains good practices for the selection, training, qualification, and professional development of personnel performing analysis, calibration, physical measurements, or data review using nondestructive assay equipment, methods, results, or techniques. The guide also covers NDA personnel involved with NDA equipment setup, selection, diagnosis, troubleshooting, or repair. Selection, training, and qualification programs based on this guide are intended to provide assurance that NDA personnel are qualified to perform their jobs competently. This guide presents a series of options but does not recommend a specific course of action.

  19. A Guide for Developing Standard Operating Job Procedures for the Tertiary Chemical Treatment - Lime Precipitation Process Wastewater Treatment Facility. SOJP No. 6.

    Science.gov (United States)

    Petrasek, Al, Jr.

    This guide describes the standard operating job procedures for the tertiary chemical treatment - lime precipitation process of wastewater treatment plants. Step-by-step instructions are given for pre-start up, start-up, continuous operation, and shut-down procedures. In addition, some theoretical material is presented along with some relevant…

  20. Determination of the sensitization of two coatings by steel welding 308l by the EPR-Dl and Astm A-262 practice A techniques; Determinacion de la sensibilizacion de dos revestimientos por soldadura de acero 308L por las tecnicas EPR-DL y ASTM A-262 practica A

    Energy Technology Data Exchange (ETDEWEB)

    Arganis J, C. R.; Zenteno S, J. C.; Robles F, J. L.; Rodriguez M, E.; Vazquez P, A., E-mail: carlos.arganis@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2014-10-15

    A stainless steel 308l coating was deposited by the shielded metal arc welding (SMAW) on steel A36 with a thickness of 4.726 mm in three layers. The sensitization was measured with the technique of Electrochemical Potentiodynamic Reactivation of Double-loop (EPR-Dl), using a portable cell and other of conventional window. The standard Astm A-262, practice A was used to verify the sensitization values. Two samples were used, a welding on a plate of 323 x 172 x 76.2 mm and the second welding on the end of a plate of 12.7 mm of thickness and 280 mm of longitude, with a post-welding process with gas tungsten arc welding (GTAW) with electrode ERNiCr{sub 3} and a process SMAW with electrode ENICRFe{sub 3}. The coating on the plate showed low values of sensitization grade (DOS) in all the points, indicating a very quick heat extraction and an inter dendritic structure type step. The second sample presented DOS values that are related with a structure of low sensitization and the influence of the heat of the post-welding process and a structure of recrystallized grains. (Author)

  1. Model of ASTM Flammability Test in Microgravity: Iron Rods

    Science.gov (United States)

    Steinberg, Theodore A; Stoltzfus, Joel M.; Fries, Joseph (Technical Monitor)

    2000-01-01

    There is extensive qualitative results from burning metallic materials in a NASA/ASTM flammability test system in normal gravity. However, this data was shown to be inconclusive for applications involving oxygen-enriched atmospheres under microgravity conditions by conducting tests using the 2.2-second Lewis Research Center (LeRC) Drop Tower. Data from neither type of test has been reduced to fundamental kinetic and dynamic systems parameters. This paper reports the initial model analysis for burning iron rods under microgravity conditions using data obtained at the LERC tower and modeling the burning system after ignition. Under the conditions of the test the burning mass regresses up the rod to be detached upon deceleration at the end of the drop. The model describes the burning system as a semi-batch, well-mixed reactor with product accumulation only. This model is consistent with the 2.0-second duration of the test. Transient temperature and pressure measurements are made on the chamber volume. The rod solid-liquid interface melting rate is obtained from film records. The model consists of a set of 17 non-linear, first-order differential equations which are solved using MATLAB. This analysis confirms that a first-order rate, in oxygen concentration, is consistent for the iron-oxygen kinetic reaction. An apparent activation energy of 246.8 kJ/mol is consistent for this model.

  2. Fitting psychometric functions using a fixed-slope parameter: an advanced alternative for estimating odor thresholds with data generated by ASTM E679.

    Science.gov (United States)

    Peng, Mei; Jaeger, Sara R; Hautus, Michael J

    2014-03-01

    Psychometric functions are predominately used for estimating detection thresholds in vision and audition. However, the requirement of large data quantities for fitting psychometric functions (>30 replications) reduces their suitability in olfactory studies because olfactory response data are often limited (ASTM) E679. The slope parameter of the individual-judge psychometric function is fixed to be the same as that of the group function; the same-shaped symmetrical sigmoid function is fitted only using the intercept. This study evaluated the proposed method by comparing it with 2 available methods. Comparison to conventional psychometric functions (fitted slope and intercept) indicated that the assumption of a fixed slope did not compromise precision of the threshold estimates. No systematic difference was obtained between the proposed method and the ASTM method in terms of group threshold estimates or threshold distributions, but there were changes in the rank, by threshold, of judges in the group. Overall, the fixed-slope psychometric function is recommended for obtaining relatively reliable individual threshold estimates when the quantity of data is limited.

  3. BTS statistical standards manual

    Science.gov (United States)

    2005-10-01

    The Bureau of Transportation Statistics (BTS), like other federal statistical agencies, establishes professional standards to guide the methods and procedures for the collection, processing, storage, and presentation of statistical data. Standards an...

  4. Hardness optimization of boride diffusion layer on Astm F-75 alloy using response surface methodology

    Energy Technology Data Exchange (ETDEWEB)

    Arguelles O, J. L.; Corona R, M. A. [Universidad Autonoma de San Luis Potosi, Doctorado Institucional en Ingenieria y Ciencia de Materiales, San Luis Potosi 78000, SLP (Mexico); Marquez H, A.; Saldana R, A. L.; Saldana R, A. [Universidad de Guanajuato, Ingenieria Mecanica Agricola DICIVA, Irapuato, Guanajuato 36500 (Mexico); Moreno P, J., E-mail: amarquez@ugto.mx [Universidad de Guanajuato, Departamento de Minas, Metalurgia y Geologia, Ex-Hacienda San Matias s/n, Guanajuato, Guanajuato 36020 (Mexico)

    2017-11-01

    In this study, the Response Surface Methodology (Rsm) and Central Composite Design (Ccd) were used to optimize the hardness of boride diffusion layer on Astm F-75 alloy (also called Haynes alloy). A boronizing thermochemical treatment was carried out at different temperatures and for different time periods. Hardness tests were conducted. The boride diffusion layer was verified by the X-ray diffraction (XRD) analysis indicating the formation of Co B, Co{sub 2}B, Cr B and Mo{sub 2}B phases. An optimal hardness of 3139.7 Hv was obtained for the samples subjected to the boriding process for a duration of 6.86 h at 802.4 degrees Celsius. (Author)

  5. ASTM F1717 standard for the preclinical evaluation of posterior spinal fixators: can we improve it?

    Science.gov (United States)

    La Barbera, Luigi; Galbusera, Fabio; Villa, Tomaso; Costa, Francesco; Wilke, Hans-Joachim

    2014-10-01

    Preclinical evaluation of spinal implants is a necessary step to ensure their reliability and safety before implantation. The American Society for Testing and Materials reapproved F1717 standard for the assessment of mechanical properties of posterior spinal fixators, which simulates a vertebrectomy model and recommends mimicking vertebral bodies using polyethylene blocks. This set-up should represent the clinical use, but available data in the literature are few. Anatomical parameters depending on the spinal level were compared to published data or measurements on biplanar stereoradiography on 13 patients. Other mechanical variables, describing implant design were considered, and all parameters were investigated using a numerical parametric finite element model. Stress values were calculated by considering either the combination of the average values for each parameter or their worst-case combination depending on the spinal level. The standard set-up represents quite well the anatomy of an instrumented average thoracolumbar segment. The stress on the pedicular screw is significantly influenced by the lever arm of the applied load, the unsupported screw length, the position of the centre of rotation of the functional spine unit and the pedicular inclination with respect to the sagittal plane. The worst-case combination of parameters demonstrates that devices implanted below T5 could potentially undergo higher stresses than those described in the standard suggestions (maximum increase of 22.2% at L1). We propose to revise F1717 in order to describe the anatomical worst case condition we found at L1 level: this will guarantee higher safety of the implant for a wider population of patients. © IMechE 2014.

  6. On-Board Monitoring of Engine Oil

    Science.gov (United States)

    2011-04-01

    methods involve potentiometric and colorimetric titrations , respectively. For both tests, a titration solvent is prepared and added to the oil. The...ASTM D 2896 and ASTM D 4739 [17]. Both methods involve potentiometric titrations . ASTM D 2896 uses a stronger acid and more polar solvent than ASTM D...Petroleum Products by Potentiometric Titration ASTM D 4739 Standard Test Method for Base Number Determination by Potentiometric Titration Gas

  7. 75 FR 28073 - Draft Regulatory Guide: Issuance, Availability

    Science.gov (United States)

    2010-05-19

    ... ``Regulatory Guides'' collection of the NRC's Electronic Reading Room at http://www.nrc.gov/reading-rm/doc... NUCLEAR REGULATORY COMMISSION [NRC-2010-0181] Draft Regulatory Guide: Issuance, Availability... Guide, DG-3039, ``Standard Format and Content for Emergency Plans for Fuel Cycle and Materials...

  8. 75 FR 45166 - Draft Regulatory Guide: Issuance, Availability

    Science.gov (United States)

    2010-08-02

    ... ``Regulatory Guides'' collection of the NRC's Electronic Reading Room at http://www.nrc.gov/reading-rm/doc... NUCLEAR REGULATORY COMMISSION [NRC-2010-0265] Draft Regulatory Guide: Issuance, Availability... Guide, DG-3030, ``Nuclear Criticality Safety Standards for Fuels and Material Facilities.'' [[Page 45167...

  9. International cooperative effort to establish dosimetry standardization for radiation processing

    International Nuclear Information System (INIS)

    Farrar, Harry IV

    1990-01-01

    Radiation processing is a rapidly developing technology with numerous applications in food treatment, sterilization, and polymer modification. The effectiveness of the process depends, however, on the proper application of dose and its measurement. These aspects are being considered by a wide group of experts from around the world who have joined together to write a comprehensive set of standards for dosimetry for radiation processing. Originally formed in 1984 to develop standards for food processing dosimetry, the group has now expanded into a full subcommittee of the American Society for Testing and Materials (ASTM), with 97 members from 19 countries. The scope of the standards now includes dosimetry for all forms and applications of radiation processing. To date, the group has completed and published four standards, and is working on an additional seven. Three are specifically for food applications and the others are for all radiation applications, including food processing. Together, this set of standards will specify acceptable guidelines and methods for accomplishing the required irradiation treatment. This set will be available for adoption by national regulatory agencies or other standards-setting organizations for their procedures and protocols. (author)

  10. 40 CFR 80.580 - What are the sampling and testing methods for sulfur?

    Science.gov (United States)

    2010-07-01

    ... [email protected] from the ASTM Web site of http://www.astm.org. (i) ASTM standard method D2622-05 (“ASTM... methods for sulfur? 80.580 Section 80.580 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... the sampling and testing methods for sulfur? The sulfur content of diesel fuel and diesel fuel...

  11. Characterisation of middle-distillates by comprehensive two-dimensional gas chromatography (GC x GC): A powerful alternative for performing various standard analysis of middle-distillates.

    Science.gov (United States)

    Vendeuvre, Colombe; Ruiz-Guerrero, Rosario; Bertoncini, Fabrice; Duval, Laurent; Thiébaut, Didier; Hennion, Marie-Claire

    2005-09-09

    The detailed characterisation of middle distillates is essential for a better understanding of reactions involved in refining process. Owing to higher resolution power and enhanced sensitivity, comprehensive two-dimensional gas chromatography (GC x GC) is a powerful tool for improving characterisation of petroleum samples. The aim of this paper is to compare GC x GC and various ASTM methods -- gas chromatography (GC), liquid chromatography (LC) and mass spectrometry (MS) -- for group type separation and detailed hydrocarbon analysis. Best features of GC x GC are demonstrated and compared to these techniques in terms of cost, time consumption and accuracy. In particular, a new approach of simulated distillation (SimDis-GC x GC) is proposed: compared to the standard method ASTM D2887 it gives unequal information for better understanding of conversion process.

  12. Determination of CTOD C in Fibre Metal Laminates by ASTM and Schwalbe Methods

    Directory of Open Access Journals (Sweden)

    E.M. Castrodeza

    2002-06-01

    Full Text Available Fibre Metal Laminates (FMLs have arisen as a demand of the aeronautical industry to use thin sheets with high resistance to fatigue crack growth, high damage tolerance, corrosion resistance and high specific strength. Considering these requirements, FMLs are an advantageous choice when compared to metal alloys currently used. In order to employ FMLs in aircraft structures, designers must hold a deep knowledge of a wide set of their properties including fracture toughness. The aim of this work was to evaluate the available methodologies to measure fracture toughness at instability (CTOD C in unidirectional fibre metal laminates reinforced with aramid fibres (ARALL®. To achieve this, tests were performed to obtain traditional and Schwalbe CTODs by using experimental ASTM based techniques, especially adapted to these laminates. Results achieved point out that Schwalbe method is more appropriate and also that there are differences between both CTOD parameters.

  13. Biodiesel Fuel Quality and the ASTM Biodiesel Standard

    Science.gov (United States)

    Biodiesel is usually produced from vegetable oils, animal fats and used cooking oils with alternative feedstocks such as algae receiving increasing interest. The transesterification reaction which produces biodiesel also produces glycerol and proceeds stepwise via mono- and diacylglycerol intermedi...

  14. Zyoptix wavefront-guided versus standard photorefractive keratectomy (PRK) in low and moderate myopia: randomized controlled 6-month study.

    Science.gov (United States)

    Mastropasqua, L; Toto, L; Zuppardi, E; Nubile, M; Carpineto, P; Di Nicola, M; Ballone, E

    2006-01-01

    To evaluate the refractive and aberrometric outcome of wavefront-guided photorefractive keratectomy (PRK) compared to standard PRK in myopic patients. Fifty-six eyes of 56 patients were included in the study and were randomly divided into two groups. The study group consisted of 28 eyes with a mean spherical equivalent (SE) of -2.25+/-0.76 diopters (D) (range: -1.5 to -3.5 D) treated with wavefront-guided PRK using the Zywave ablation profile and the Bausch & Lomb Technolas 217z excimer laser (Zyoptix system) and the control group included 28 eyes with a SE of -2.35+/-1.01 D (range: -1.5 to -3.5 D) treated with standard PRK (PlanoScan ablation) using the same laser. A Zywave aberrometer was used to analyze and calculate the root-mean-square (RMS) of total high order aberrations (HOA) and Zernike coefficients of third and fourth order before and after (over a 6-month follow-up period) surgery in both groups. Preoperative and postoperative SE, un-corrected visual acuity (UCVA), and best-corrected visual acuity (BCVA) were evaluated in all cases. There was a high correlation between achieved and intended correction. The differences between the two treatment groups were not statistically significant for UCVA, BCVA, or SE cycloplegic refraction . Postoperatively the RMS value of high order aberrations was raised in both groups. At 6-month control, on average it increased by a factor of 1.17 in the Zyoptix PRK group and 1.54 in the PlanoScan PRK group (p=0.22). In the Zyoptix group there was a decrease of coma aberration, while in the PlanoScan group this third order aberration increased. The difference between postoperative and preoperative values between the two groups was statistically significant for coma aberration (p=0.013). No statistically significant difference was observed for spherical-like aberration between the two groups. In the study group eyes with a low amount of preoperative aberrations (HOA RMS lower than the median value; PRK is as safe and

  15. Sequestration Coating Performance Requirements for Mitigation of Contamination from a Radiological Dispersion Device

    International Nuclear Information System (INIS)

    Drake, J.

    2009-01-01

    Immediate action would be necessary to minimize the effects of a radiological 'dirty bomb' detonation in a major city. After a dirty bomb has been detonated, vehicular and pedestrian traffic, as well as weather effects, would increase the spread of loose contamination, making control and recovery more difficult and costly. While contaminant migration and chemical binding into surface materials can be relatively rapid, the immediate treatment of surfaces with large quantities of an appropriate compound could alleviate much of the difficulty in decontamination. The EPA's National Homeland Security Research Center (NHSRC), in collaboration with ASTM International, is currently developing performance standards for materials which could be applied to exterior surfaces contaminated by an RDD to mitigate the spread and migration of radioactive contamination. These performance standards are being promulgated via an ASTM Standard Specification to be published by ASTM International. Test methods will be developed to determine if candidate coatings meet the performance requirements stipulated in the ASTM performance standard. These test methods will be adapted from existing standard methods, or will be devised through laboratory research. The final set of test methods will be codified in an ASTM or other standard test method. The principal market for products described in the ASTM performance standard would be federal, state and local government emergency responders and response planners, decontamination service providers and those whose interests include protection and recovery of real estate potentially at risk from radiological terrorism. (authors)

  16. Practice for dosimetry for a self-contained dry-storage gamma-ray irradiator

    International Nuclear Information System (INIS)

    2002-01-01

    This practice outlines dosimetric procedures to be followed with self-contained dry-storage gamma-ray irradiators. If followed, these procedures will help to ensure that calibration and testing will be carried out with acceptable precision and accuracy and that the samples processed with ionizing radiation from gamma rays in a self-contained dry-storage irradiator receive absorbed doses within a predetermined range. This practice covers dosimetry in the use of dry-storage gamma-ray irradiators, namely self-contained dry storage 137 Cs or 60 Co irradiators (shielded free-standing irradiators). It does not cover underwater pool sources, panoramic gamma-ray sources such as those raised mechanically or pneumatically to irradiate isotropically into a room or through a collimator, nor does it cover self-contained bremsstrahlung x-ray units. The absorbed dose range for the use of the dry-storage self-contained gamma-ray irradiators covered by this practice is typically 1 to 10 5 Gy, depending on the application. The absorbed-dose rate range typically is from 10 -2 to 10 3 Gy/min. This practice describes general procedures applicable to all self-contained dry-storage gamma-ray irradiators. For procedures specific to dosimetry in blood irradiation, see ISO/ ASTM Practice 51939. For procedures specific to dosimetry in radiation research on food and agricultural products, see ISO/ASTM Practice 51900. For procedures specific to radiation hardness testing, see ASTM Practice E 1249. For procedures specific to the dosimetry in the irradiation of insects for sterile release programs, see ISO/ASTM Guide 51940. In those cases covered by ISO/ASTM Practices 51939, 51900, 51940, or ASTM E 1249, those standards take precedence. In addition, this practice does not cover absorbed-dose rate calibrations of radiation protection instrumentation

  17. IEEE guide for the analysis of human reliability

    International Nuclear Information System (INIS)

    Dougherty, E.M. Jr.

    1987-01-01

    The Institute of Electrical and Electronics Engineers (IEEE) working group 7.4 of the Human Factors and Control Facilities Subcommittee of the Nuclear Power Engineering Committee (NPEC) has released its fifth draft of a Guide for General Principles of Human Action Reliability Analysis for Nuclear Power Generating Stations, for approval of NPEC. A guide is the least mandating in the IEEE hierarchy of standards. The purpose is to enhance the performance of an human reliability analysis (HRA) as a part of a probabilistic risk assessment (PRA), to assure reproducible results, and to standardize documentation. The guide does not recommend or even discuss specific techniques, which are too rapidly evolving today. Considerable maturation in the analysis of human reliability in a PRA context has taken place in recent years. The IEEE guide on this subject is an initial step toward bringing HRA out of the research and development arena into the toolbox of standard engineering practices

  18. Standard guide for laboratory simulation of corrosion under insulation

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This guide covers the simulation of corrosion under insulation (CUI), including both general and localized attack, on insulated specimens cut from pipe sections exposed to a corrosive environment usually at elevated temperature. It describes a CUI exposure apparatus (hereinafter referred to as a CUI-Cell), preparation of specimens, simulation procedures for isothermal or cyclic temperature, or both, and wet/dry conditions, which are parameters that need to be monitored during the simulation and the classification of simulation type. 1.2 The application of this guide is broad and can incorporate a range of materials, environments and conditions that are beyond the scope of a single test method. The apparatus and procedures contained herein are principally directed at establishing acceptable procedures for CUI simulation for the purposes of evaluating the corrosivity of CUI environments on carbon and low alloy pipe steels, and may possibly be applicable to other materials as well. However, the same or simi...

  19. Radiological design guide

    International Nuclear Information System (INIS)

    Evans, R.A.

    1994-01-01

    The purpose of this design guide is to provide radiological safety requirements, standards, and information necessary for designing facilities that will operate without unacceptable risk to personnel, the public, or the environment as required by the US Department of Energy (DOE). This design guide, together with WHC-CM-4-29, Nuclear Criticality Safety, WHC-CM-4-46, Nonreactor Facility Safety Analysis, and WHC-CM-7-5, Environmental Compliance, covers the radiation safety design requirements at Westinghouse Hanford Company (WHC). This design guide applies to the design of all new facilities. The WHC organization with line responsibility for design shall determine to what extent this design guide shall apply to the modifications to existing facilities. In making this determination, consideration shall include a cost versus benefit study. Specifically, facilities that store, handle, or process radioactive materials will be covered. This design guide replaces WHC-CM-4-9 and is designated a living document. This design guide is intended for design purposes only. Design criteria are different from operational criteria and often more stringent. Criteria that might be acceptable for operations might not be adequate for design

  20. Standard practice for leaks using bubble emission techniques

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This practice describes accepted procedures for and factors that influence laboratory immersion corrosion tests, particularly mass loss tests. These factors include specimen preparation, apparatus, test conditions, methods of cleaning specimens, evaluation of results, and calculation and reporting of corrosion rates. This practice also emphasizes the importance of recording all pertinent data and provides a checklist for reporting test data. Other ASTM procedures for laboratory corrosion tests are tabulated in the Appendix. (Warning-In many cases the corrosion product on the reactive metals titanium and zirconium is a hard and tightly bonded oxide that defies removal by chemical or ordinary mechanical means. In many such cases, corrosion rates are established by mass gain rather than mass loss.) 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. This standard does not purport to address all of the safety concerns, if any, assoc...

  1. Standard guide to In-Plant performance evaluation of Hand-Held SNM monitors

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This guide is one of a series on the application and evaluation of special nuclear material (SNM) monitors. Other guides in the series are listed in Section 2, and the relationship of in-plant performance evaluation to other procedures described in the series is illustrated in Fig. 1. Hand-held SNM monitors are described in of Guide C1112, and performance criteria illustrating their capabilities can be found in Appendix X1. 1.2 The purpose of this guide to in-plant performance evaluation is to provide a comparatively rapid procedure to verify that a hand-held SNM monitor performs as expected for detecting SNM or alternative test sources or to disclose the need for repair. The procedure can be used as a routine operational evaluation or it can be used to verify performance after a monitor is calibrated. 1.3 In-plant performance evaluations are more comprehensive than daily functional tests. They take place less often, at intervals ranging from weekly to once every three months, and derive their result fr...

  2. Structural integrity assessment and stress measurement of CHASNUPP-1 fuel assembly

    Directory of Open Access Journals (Sweden)

    Waseem

    2016-01-01

    less than the design stress limit of the materials used for the grid [ASTM, Standard specification for precipitation hardening nickel alloy (UNSN07718 plate, sheet, and strip for high temperature service, B 670-80, USA, 2013], fuel rod [ASTM, Standard specification for wrought zirconium alloy seamless tubes for nuclear reactor fuel cladding, B 811-02, USA, 2002] and the guide thimble [ASTM, Standard specification for seamless stainless steel mechanical tubing, A 511-04, USA, 2004]. Therefore, the structural integrity criterion of CHASNUPP-1 fuel assembly is fulfilled safely at the specified tensile load.

  3. Sensitivities of a Standard Test Method for the Determination of the pHe of Bioethanol and Suggestions for Improvement

    Directory of Open Access Journals (Sweden)

    Paul J. Brewer

    2010-11-01

    Full Text Available An assessment of the sensitivities of the critical parameters in the ASTM D6423 documentary standard method for the measurement of pHe in (bioethanol has been undertaken. Repeatability of measurements made using the same glass electrode and reproducibility between different glass electrodes have been identified as the main contributors to the uncertainty of the values produced. Strategies to reduce the uncertainty of the measurement have been identified and tested. Both increasing the time after which the pHe measurement is made following immersion in the sample, and rinsing the glass electrode with ethanol prior to immersion in the sample, have been shown to be effective in reducing the uncertainty of the numerical value produced. However, it is acknowledged that the values produced using these modified approaches may not be directly compared with those obtained using the documentary ASTM method since pHe is defined operationally by the process used to measure it.

  4. Guide to Permitting Hydrogen Motor Fuel Dispensing Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Rivkin, Carl [National Renewable Energy Lab. (NREL), Golden, CO (United States); Buttner, William [National Renewable Energy Lab. (NREL), Golden, CO (United States); Burgess, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-03-28

    The purpose of this guide is to assist project developers, permitting officials, code enforcement officials, and other parties involved in developing permit applications and approving the implementation of hydrogen motor fuel dispensing facilities. The guide facilitates the identification of the elements to be addressed in the permitting of a project as it progresses through the approval process; the specific requirements associated with those elements; and the applicable (or potentially applicable) codes and standards by which to determine whether the specific requirements have been met. The guide attempts to identify all applicable codes and standards relevant to the permitting requirements.

  5. Characterization of ASTM A335 P92 steel in continuous cooling cycles

    International Nuclear Information System (INIS)

    Xaubet, M. N.; Danón, C. A.; Ramos, C. P.

    2013-01-01

    The operating conditions demanded by Generation IV reactors include high temperatures, higher radiation doses and highly corrosive environments. Among the structural materials proposed both for in-core and out-of-core applications, elevated-temperature P91/P92 ferritic/martensitic steels have been considered. This work studies the transformation behavior and microstructural evolution of ASTM A335 P92 steel in continuous cooling cycles (CCT). The material was austenized at 1050 ºC and afterwards cooled down at controlled rates (300, 50 and 15 ºC/h). The determination and characterization of the phases present in the samples was performed by optical microscopy, field emission scanning electron microscopy, Mössbauer spectroscopy and X-ray diffraction. Samples whose cooling rates were on the limits of the studied range (300 and 15 ºC/h) presented completely martensitic and completely ferritic structures, respectively. The sample cooled down at intermediate rate exhibited, though, a mixed structure of martensite and ferrite. Second-phase precipitation has also been observed in all the samples. (author)

  6. Standard methods for sampling and sample preparation for gamma spectroscopy

    International Nuclear Information System (INIS)

    Taskaeva, M.; Taskaev, E.; Nikolov, P.

    1993-01-01

    The strategy for sampling and sample preparation is outlined: necessary number of samples; analysis and treatment of the results received; quantity of the analysed material according to the radionuclide concentrations and analytical methods; the minimal quantity and kind of the data needed for making final conclusions and decisions on the base of the results received. This strategy was tested in gamma spectroscopic analysis of radionuclide contamination of the region of Eleshnitsa Uranium Mines. The water samples was taken and stored according to the ASTM D 3370-82. The general sampling procedures were in conformity with the recommendations of ISO 5667. The radionuclides was concentrated by coprecipitation with iron hydroxide and ion exchange. The sampling of soil samples complied with the rules of ASTM C 998, and their sample preparation - with ASTM C 999. After preparation the samples were sealed hermetically and measured. (author)

  7. Standard guide for measuring the wear volumes of piston ring segments run against flat coupons in reciprocating wear tests

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This guide covers and describes a profiling method for use accurately measuring the wear loss of compound-curved (crowned) piston ring specimens that run against flat counterfaces. It does not assume that the wear scars are ideally flat, as do some alternative measurement methods. Laboratory-scale wear tests have been used to evaluate the wear of materials, coatings, and surface treatments that are candidates for piston rings and cylinder liners in diesel engines or spark ignition engines. Various loads, temperatures, speeds, lubricants, and durations are used for such tests, but some of them use a curved piston ring segment as one sliding partner and a flat or curved specimen (simulating the cylinder liner) as its counterface. The goal of this guide is to provide more accurate wear measurements than alternative approaches involving weight loss or simply measuring the length and width of the wear marks. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its ...

  8. U.S. Air Force School of Aerospace Medicine Laboratory Sampling and Analysis Guide

    Science.gov (United States)

    2016-11-15

    Clay Sand Gravel Page | 63 DISTRIBUTION STATEMENT A. Approved for public release. Distribution is unlimited. Cleared, 88PA, # 2014-0577...solid/liquid, media will collect semi-liquid only. Not for high viscosity liquids. Dipper (or “pond sampler”) ASTM D5358 ASTM D5013 USEPA...decontamination may be difficult. Limited by length of sampler, small volume of sample collected, and viscosity of fluids. Page | 71

  9. Development and Evaluation of a Novel Curved Biopsy Device for CT-Guided Biopsy of Lesions Unreachable Using Standard Straight Needle Trajectories

    Energy Technology Data Exchange (ETDEWEB)

    Schulze-Hagen, Maximilian Franz, E-mail: mschulze@ukaachen.de; Pfeffer, Jochen; Zimmermann, Markus; Liebl, Martin [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology (Germany); Stillfried, Saskia Freifrau von [University Hospital RWTH Aachen, Department of Pathology (Germany); Kuhl, Christiane; Bruners, Philipp; Isfort, Peter [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology (Germany)

    2017-06-15

    PurposeTo evaluate the feasibility of a novel curved CT-guided biopsy needle prototype with shape memory to access otherwise not accessible biopsy targets.Methods and MaterialsA biopsy needle curved by 90° with specific radius was designed. It was manufactured using nitinol to acquire shape memory, encased in a straight guiding trocar to be driven out for access of otherwise inaccessible targets. Fifty CT-guided punctures were conducted in a biopsy phantom and 10 CT-guided punctures in a swine corpse. Biposies from porcine liver and muscle tissue were separately gained using the biopsy device, and histological examination was performed subsequently.ResultsMean time for placement of the trocar and deployment of the inner biopsy needle was ~205 ± 69 and ~93 ± 58 s, respectively, with a mean of ~4.5 ± 1.3 steps to reach adequate biopsy position. Mean distance from the tip of the needle to the target was ~0.7 ± 0.8 mm. CT-guided punctures in the swine corpse took relatively longer and required more biopsy steps (~574 ± 107 and ~380 ± 148 s, 8 ± 2.6 steps). Histology demonstrated appropriate tissue samples in nine out of ten cases (90%).ConclusionsTargets that were otherwise inaccessible via standard straight needle trajectories could be successfully reached with the curved biopsy needle prototype. Shape memory and preformed size with specific radius of the curved needle simplify the target accessibility with a low risk of injuring adjacent structures.

  10. 75 FR 43107 - Revocation of Requirements for Full-Size Baby Cribs and Non-Full-Size Baby Cribs

    Science.gov (United States)

    2010-07-23

    ...] Revocation of Requirements for Full-Size Baby Cribs and Non-Full- Size Baby Cribs AGENCY: Consumer Product... standards, and include ASTM F 1169-10, ``Standard Consumer Safety Specification for Full-Size Baby Cribs,'' and ASTM F 406-10, ``Standard Consumer Safety Specification for Non-Full-Size Baby Cribs/Play Yards...

  11. The fatigue-crack propagation behavior of ASTM A533-B steel tested in vacuo at LWR operating temperatures

    International Nuclear Information System (INIS)

    James, L.A.

    1987-01-01

    The fatigue-crack propagation (FCP) behavior of ASTM A533-B-1 steel was characterized in vacuo at 288 0 C. Tests were conducted at two stress ratios: R = 0.05 and R = 0.7. Results of these tests were compared with results from previous studies for the same type of steel tested in an air environment, and FCP rates in vacuo were generally lower than those in air. Stress ratio effects in vacuo were not as great as those in air, and both stress ratio effects and environmental effects are discussed from the standpoint of crack closure concepts

  12. Standard guide for characterization of radioactive and/or hazardous wastes for thermal treatment

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This guide identifies methods to determine the physical and chemical characteristics of radioactive and/or hazardous wastes before a waste is processed at high temperatures, for example, vitrification into a homogeneous glass ,glass-ceramic, or ceramic waste form. This includes waste forms produced by ex-situ vitrification (ESV), in-situ vitrification (ISV), slagging, plasma-arc, hot-isostatic pressing (HIP) and/or cold-pressing and sintering technologies. Note that this guide does not specifically address high temperature waste treatment by incineration but several of the analyses described in this guide may be useful diagnostic methods to determine incinerator off-gas composition and concentrations. The characterization of the waste(s) recommended in this guide can be used to (1) choose and develop the appropriate thermal treatment methodology, (2) determine if waste pretreatment is needed prior to thermal treatment, (3) aid in development of thermal treatment process control, (4) develop surrogate wa...

  13. 75 FR 12804 - Withdrawal of Regulatory Guide 8.6

    Science.gov (United States)

    2010-03-17

    ... ``Regulatory Guides'' in the NRC's Electronic Reading Room at http://www.nrc.gov/reading-rm/doc-collections... NUCLEAR REGULATORY COMMISSION [NRC-2010-0103] Withdrawal of Regulatory Guide 8.6 AGENCY: Nuclear Regulatory Commission. ACTION: Withdrawal of Regulatory Guide 8.6, ``Standard Test Procedure for Geiger-M...

  14. [Development of a standardized guide for optimizing drug adherence information to be dispensed during a pharmaceutical counseling with a multiple myeloma patient: Initial validation].

    Science.gov (United States)

    Favier-Archinard, Camille; Leguelinel-Blache, Géraldine; Dubois, Florent; Le Gall, Tanguy; Bourquard, Pascal; Passemard, Nadège; Tora, Sandrine; Rey, Aurélie; Rossi, Marie; Chevallier, Thierry; Cousin, Christelle; Favier, Mireille

    2018-05-01

    The safety of the community treatment with oral anticancer therapies is a strong theme of the cancer plan 2014-2019. The objective of this study was to develop a Pharmaceutical Counseling Guide to improve medication adherence in patients treated for multiple myeloma with oral anticancer therapies. A multidisciplinary professional working group selected a list of relevant medication adherence-related items that served as the framework for the design of the pharmaceutical counseling support materials in patient-accessible language. The readability, understanding and memorization of the information were validated in ten patients treated for myeloma. Twelve items were selected for treatment information (5 items), treatment planning (5 items), and adverse drug effects (2 items). A pharmacist guide, a patient guide, a medication schedule, and three self-questionnaires to evaluate medication knowledge and understanding of patients were developed. The patient test resulted in changes in these documents. This study carried out the initial validation of documents to standardize the pharmaceutical counseling for patients treated for myeloma so that it can be reproduced from one patient to another regardless of the pharmacist, by standardizing the information issued. This study needs to be completed by a final validation in myeloma patients, free from oral anticancer therapies. Copyright © 2018 Société Française du Cancer. Published by Elsevier Masson SAS. All rights reserved.

  15. Effects of Water Hardness on Spray Droplet Size Under Aerial Application Conditions

    Science.gov (United States)

    2008-01-01

    Nonimaging Light‐Scattering Instruments (ASTM, 2003). Table 1. Spray formulations for water hardness levels. Hardness (ppm) Tank, L (gal) Kocide, kg (lb...characteristics in a spray using optical nonimaging light‐scattering instruments. W. Conshohocken, Pa.: ASTM Intl. ASTM. 2004. E1620‐97. Standard

  16. Determination of the sensitization of two coatings by steel welding 308l by the EPR-Dl and Astm A-262 practice A techniques

    International Nuclear Information System (INIS)

    Arganis J, C. R.; Zenteno S, J. C.; Robles F, J. L.; Rodriguez M, E.; Vazquez P, A.

    2014-10-01

    A stainless steel 308l coating was deposited by the shielded metal arc welding (SMAW) on steel A36 with a thickness of 4.726 mm in three layers. The sensitization was measured with the technique of Electrochemical Potentiodynamic Reactivation of Double-loop (EPR-Dl), using a portable cell and other of conventional window. The standard Astm A-262, practice A was used to verify the sensitization values. Two samples were used, a welding on a plate of 323 x 172 x 76.2 mm and the second welding on the end of a plate of 12.7 mm of thickness and 280 mm of longitude, with a post-welding process with gas tungsten arc welding (GTAW) with electrode ERNiCr 3 and a process SMAW with electrode ENICRFe 3 . The coating on the plate showed low values of sensitization grade (DOS) in all the points, indicating a very quick heat extraction and an inter dendritic structure type step. The second sample presented DOS values that are related with a structure of low sensitization and the influence of the heat of the post-welding process and a structure of recrystallized grains. (Author)

  17. 45 CFR 162.1302 - Standards for referral certification and authorization transaction.

    Science.gov (United States)

    2010-10-01

    ... Standards for Electronic Data Interchange Technical Report Type 3, April 2008, ASC X12N/005010X217E1... authorization. The NCPDP Telecommunication Standard Implementation Guide, Version 5, Release 1 (Version 5.1... (Version 1.1), January 2000, supporting Telecommunications Standard Implementation Guide, Version 5...

  18. [Comparison of susceptibility artifacts generated by microchips with different geometry at 1.5 Tesla magnet resonance imaging. A phantom pilot study referring to the ASTM standard test method F2119-07].

    Science.gov (United States)

    Dengg, S; Kneissl, S

    2013-01-01

    Ferromagnetic material in microchips, used for animal identification, causes local signal increase, signal void or distortion (susceptibility artifact) on MR images. To measure the impact of microchip geometry on the artifact's size, an MRI phantom study was performed. Microchips of the labels Datamars®, Euro-I.D.® and Planet-ID® (n  =  15) were placed consecutively in a phantom and examined with respect to the ASTM Standard Test Method F2119-07 using spin echo (TR 500 ms, TE 20 ms), gradient echo (TR 300 ms, TE 15 ms, flip angel 30°) and otherwise constant imaging parameters (slice thickness 3 mm, field of view 250 x 250 mm, acquisition matrix 256 x 256 pixel, bandwidth 32 kHz) at 1.5 Tesla. Image acquisition was undertaken with a microchip positioned in the x- and z-direction and in each case with a phase-encoding direction in the y- and z-direction. The artifact size was determined with a) a measurement according to the test method F2119-07 using a homogeneous point operation, b) signal intensity measurement according to Matsuura et al. and c) pixel counts in the artifact according to Port and Pomper. There was a significant difference in artifact size between the three microchips tested (Wilcoxon p = 0.032). A two- to three-fold increase in microchip volume generated an up to 76% larger artifact, depending on the sequence type, phase-encoding direction and chip position to B0. The smaller the microchip geometry, the less is the susceptibility artifact. Spin echoes (SE) generated smaller artifacts than gradient echoes (GE). In relation to the spatial measurement of the artifact, the switch in phase-encoding direction had less influence on the artifact size in GE- than in SE-sequences. However, the artifact shape and direction of SE-sequences can be changed by altering the phase. The artifact size, caused by the microchip, plays a major clinical role in the evaluation of MRI from the head, shoulder and neck regions.

  19. 29 CFR 1918.104 - Foot protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Foot protection. 1918.104 Section 1918.104 Labor... following consensus standards: (i) ASTM F-2412-2005, “Standard Test Methods for Foot Protection,” and ASTM F... footwear that is constructed in accordance with one of the above consensus standards will be deemed to be...

  20. 40 CFR 89.6 - Reference materials.

    Science.gov (United States)

    2010-07-01

    ... Distillation of Petroleum Products at Atmospheric Pressure” Appendix A to Subpart D. ASTM D93-97: “Standard... D287-92: “Standard Test Method for API Gravity of Crude Petroleum and Petroleum Products” (Hydrometer...: “Standard Test Method for Cetane Number of Diesel Fuel Oil” Appendix A to Subpart D. ASTM D1319-98...

  1. Development of format and contents of safety analysis report for the KNGR standard design

    International Nuclear Information System (INIS)

    Lee, J. H.; Kim, H. S.; Yun, Y. K. and others

    1999-01-01

    Referring to the USNRC Regulatory Guide 1.70 which has been used in the preparation of the SAR for conventional nuclear power plants, the draft guide for format and contents of the SAR for the KNGR standard design was developed based on new regulatory information related to advanced reactors. The draft guide will enable the regulator to make an effective and consistent review on the safety of the KNGR, when this draft guide is used, since the draft guide requires more specific and additional safety information for the standardized NPPs than RG 1.70. In addition, it is expected that the guide for the format and contents of the COL's SAR will be more easily developed using the draft guide suggested in this report. Also, the draft guide can serve as the Korean national guide, with the exception to some industry codes and standards. The experts' review will be performed during the next stage of the project to ensure the objectivity and consistency of the draft guide developed in this study. After reflecting the experts' comments in the guide and revising the contents, it will be utilized in the licensing activities for the KNGR standard design

  2. Guide for selection and calibration of dosimetry systems for radiation processing

    International Nuclear Information System (INIS)

    2002-01-01

    This guide covers the basis for selecting and calibrating dosimetry systems used to measure absorbed dose in gamma ray or X-ray fields and in electron beams used for radiation processing. It discusses the types of dosimetry systems that may be employed during calibration or on a routine basis as part of quality assurance in commercial radiation processing of products. This guide also discusses interpretation of absorbed dose and briefly outlines measurements of the uncertainties associated with the dosimetry. The details of the calibration of the analytical instrumentation are addressed in individual dosimetry system standard practices. The absorbed-dose range covered is up to 1 MGy (100 Mrad). Source energies covered are from 0.1 to 50 MeV photons and electrons. This guide should be used along with standard practices and guides for specific dosimetry systems and applications covered in other standards. Dosimetry for radiation processing with neutrons or heavy charged particles is not covered in this guide

  3. Ornamental Horticulture Production Occupations. Curriculum Guide.

    Science.gov (United States)

    Reneau, Fred; And Others

    This curriculum guide contains guidesheets for the ornamental horticulture production occupations. Each guidesheet provides a job-relevant task; performance objective, with task, performance standard, source of standard, and conditions for performance of task; enabling objectives; a list of resources; teaching activities; a criterion-referenced…

  4. COMPOZ data guide

    International Nuclear Information System (INIS)

    Knight, J.R.

    1984-01-01

    The COMPOZ Data Guide used to create the Standard Composition Library is described. Of particular importance is documentation of the COMPOZ input data file structure. Knowledge of the file structure allows users to edit the data file and subsequently create their own site-specific composition library

  5. VALIDATION OF ANALYTICAL METHODS AND INSTRUMENTATION FOR BERYLLIUM MEASUREMENT: REVIEW AND SUMMARY OF AVAILABLE GUIDES, PROCEDURES, AND PROTOCOLS

    Energy Technology Data Exchange (ETDEWEB)

    Ekechukwu, A

    2009-05-27

    Method validation is the process of evaluating whether an analytical method is acceptable for its intended purpose. For pharmaceutical methods, guidelines from the United States Pharmacopeia (USP), International Conference on Harmonisation (ICH), and the United States Food and Drug Administration (USFDA) provide a framework for performing such valications. In general, methods for regulatory compliance must include studies on specificity, linearity, accuracy, precision, range, detection limit, quantitation limit, and robustness. Elements of these guidelines are readily adapted to the issue of validation for beryllium sampling and analysis. This document provides a listing of available sources which can be used to validate analytical methods and/or instrumentation for beryllium determination. A literature review was conducted of available standard methods and publications used for method validation and/or quality control. A comprehensive listing of the articles, papers and books reviewed is given in the Appendix. Available validation documents and guides are listed therein; each has a brief description of application and use. In the referenced sources, there are varying approches to validation and varying descriptions of the valication process at different stages in method development. This discussion focuses on valication and verification of fully developed methods and instrumentation that have been offered up for use or approval by other laboratories or official consensus bodies such as ASTM International, the International Standards Organization (ISO) and the Association of Official Analytical Chemists (AOAC). This review was conducted as part of a collaborative effort to investigate and improve the state of validation for measuring beryllium in the workplace and the environment. Documents and publications from the United States and Europe are included. Unless otherwise specified, all referenced documents were published in English.

  6. Spontaneous ignition in afterburner segment tests at an inlet temperature of 1240 K and a pressure of 1 atmosphere with ASTM jet-A fuel

    Science.gov (United States)

    Schultz, D. F.; Branstetter, J. R.

    1973-01-01

    A brief testing program was undertaken to determine if spontaneous ignition and stable combustion could be obtained in a jet engine afterburning operating with an inlet temperature of 1240 K and a pressure of 1 atmosphere with ASTM Jet-A fuel. Spontaneous ignition with 100-percent combustion efficiency and stable burning was obtained using water-cooled fuel spraybars as flameholders.

  7. Grazing incidence synchrotron X-ray diffraction and Moessbauer spectroscopy analyses of plasma nitrided ASTM F138 stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Danilo Olzon Dionysio de; Ardisson, Jose Domingos, E-mail: dolzon@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Silva, Edilaine Honorio [Studiecentrum voor Kernenergie (Belgium); Olzon-Dionysio, Maristela; Souza, Sylvio Dionysio de; Fabris, Jose Domingos [Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM), Diamantina, MG (Brazil); Martinez, L.G. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2016-07-01

    Full text: systematic investigation of samples of plasma-nitriding austenitic stainless steels ASTM F138 and AISI 316L is reported. The surface treatment of the steels through plasma-nitriding was used to improve further the hardness, wear and corrosion resistance of these stainless steels. The resulting layered crystallographic structure actually corresponds to several phases with close cell parameters, making their identification and quantification a real experimental challenge. The ASTM F138 and AISI 316L stainless steel disks were plasma nitrided for 4 h at 400 deg C in a 80% H{sub 2} -20% N2 atmosphere at 6 torr, using plasma current frequencies between 6 and 100 kHz. Data of Moessbauer (CEMS and CXMS) and grazing incidence synchrotron X-ray diffraction (XRD-SR) were systematically collected. The nitrided layer thickness were not in general influenced by the plasma frequency, except at 12 kHz, which produced a layer thickness of approximately 8.0 mm, being in average 40% thicker than for the other samples. CXMS and CEMS Moessbauer spectra for this 12 kHz-sample show a much more pronounced magnetic resonance lines than for the other samples. The Fe{sub 4}N phase presents a single magnetic hyperfine interaction; the other two (Fe{sub 2-3}N and the expanded austenite) present both paramagnetic and magnetic components, even though their hyperfine parameters may not be safely separated. We also present the results of XRD-SR that were probed at several depths. The data from these techniques may be consistently correlated and this leads to an improved model to explain the structure of the nitrided layers. (author)

  8. User's guide for the implementation of level one of the proposed American National Standard Specifications for an information interchange data descriptive file on control data 6000/7000 series computers

    CERN Document Server

    Wiley, R A

    1977-01-01

    User's guide for the implementation of level one of the proposed American National Standard Specifications for an information interchange data descriptive file on control data 6000/7000 series computers

  9. State of the reactor vessel surveillance programs in Korea and foreign countries

    International Nuclear Information System (INIS)

    Kim, Jeong Kyu; Hwang, Jong Keun; Park, Keon Woo; Kim, Bum Sik; Jeong, Kyung Hoon

    1996-06-01

    ASTM standards are dominating all over the world in the field of the reactor vessel surveillance program. They are mainly used directly or that the national standards in use correspond quite well with ASTM. According to, however, increasing concerns about the protection of environment and safety of nuclear plant, various approaches to establish and reinforce the national standards are made actively in Europe. In addition, some methods to share the nuclear data by integrating the existing test, analysis procedures and units system are considered. For nuclear plants in Korea, MOST Notice No. 92-20 should be applied for all PWRs after UCN units 3 and 4 since it was promulgated at Dec. 1992. The notice almost reflects the contents of ASTM E 185. But, the notice has much to be desired to provide the technical back-ground for reactor vessel surveillance program because it is not a standard such as ASTM or ASME code but regulation such as CFR or RG. Several Korean Standards are also used in limited area of the surveillance program. Therefore, practical requirements and rules for surveillance program are in accordance with the ASTM and CFR. In this report, the state of application of the standards to the surveillance program in Korea and Europe are reviewed and their national standards re compared with US standards or regulations. Current level and the future prospect of surveillance technology for PWR vessel are discussed at this point of view. 15 tabs., 12 figs., 38 refs. (Author)

  10. Evaluation of the EPA Drift Reduction Technology (DRT) Low-Speed Wind Tunnel Protocol

    Science.gov (United States)

    2009-01-01

    Characteristics in a Spray Using Optical Nonimaging Light-Scattering by ASTM Int’l (all rights reserved); Thu May 7 10:08:26 EDT 2009 ed/printed by itz...Spray Using Optical Nonimaging Light-Scattering Instruments,” Annual Book of ASTM Standards, ASTM International, West Conshohocken, PA, 2003. 9

  11. 40 CFR 98.254 - Monitoring and QA/QC requirements.

    Science.gov (United States)

    2010-07-01

    ...) Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuels by Bomb Calorimeter (incorporated... methods. (1) ASTM D4809-06 Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuels by Bomb...) Method 18 at 40 CFR part 60, appendix A-6. (2) ASTM D1945-03 Standard Test Method for Analysis of Natural...

  12. Comparison of 22G reverse-beveled versus standard needle for endoscopic ultrasound-guided sampling of solid pancreatic lesions

    Science.gov (United States)

    Alatawi, Abdullah; Beuvon, Frédéric; Grabar, Sophie; Leblanc, Sarah; Chaussade, Stanislas; Terris, Benoit; Barret, Maximilien

    2015-01-01

    Objectives Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) using standard needles has a high diagnostic value in the evaluation of solid pancreatic masses. Fenestrated needles have been developed to improve the quality of EUS-guided tissue sampling by providing core biopsies (FNB). Methods Patients with solid pancreatic masses of >2 cm were prospectively included in our study and randomized to receive EUS sampling, using either a standard 22G FNA or a 22G Procore® FNB needle. The main study endpoint was the number of needle passes required to obtain a diagnosis in more than 90% of cases. Results We included 100 patients (male = 63, female = 37; mean age = 68.4 years) in our study. We found that 88% of the lesions were malignant, with a mean size of 32 mm. A sample adequate for diagnosis was obtained in more than 90% of cases after the second needle pass in the FNB group, versus the third needle pass in the FNA group. Slide cellularity and presence of tissue microfragments were significantly higher in the FNB group. Sensitivity for the diagnosis of malignancy was 88.4% versus 97.8% for the EUS-FNA and EUS-FNB group, respectively, while specificity for both techniques was 100%. No complications were recorded. Conclusions Although the accuracy of both needle types for proving malignancy was similar, a lower number of passes was required with the FNB needles to achieve the same contributive sample rate as with the FNA needles. FNB also improved the histopathological quality of specimens, suggesting an overall superiority of FNB sampling. PMID:26279842

  13. ULTRASOUND GUIDED TRANSVERSUS ABDOMINIS PLANE BLOCK VERSUS STANDARD ANALGESIC CARE FOR POSTOPERATIVE PAIN RELIEF FOLLOWING TOTAL ABDOMINAL HYSTERECTOMY, AN OBSERVATIONAL STUDY

    Directory of Open Access Journals (Sweden)

    Elizabeth Joseph

    2018-02-01

    Full Text Available BACKGROUND The transversus abdominis plane (TAP block is a technique which blocks the sensory nerves supplying the anterior abdominal wall. This prospective cohort study was done to evaluate the effectiveness of TAP block for postoperative pain in patients undergoing total abdominal hysterectomy. MATERIALS AND METHODS Sixty patients of ASA Grade 1 and 2 undergoing open abdominal hysterectomy were prospectively allocated into Group A and Group B. Group A patients (n = 30, received ultrasound guided TAP block along with 1 gm paracetamol 8th hourly and tramadol 1 mg/ kg as rescue analgesic. Group B patients (n = 30 received standard analgesic care with 1 gm paracetamol 8th hourly and tramadol 1 mg/ kg as rescue analgesic. TAP block was performed on completion of surgery in Group A patients by instilling 20 ml of 0.25% levobupivacaine into the transversus abdominis plane on each side under ultrasound guidance. Postoperatively Verbal Numerical Rating Scale, Sedation score, Nausea categorical scoring scale at 2, 4, 6, 12 and 24 hours and total tramadol requirement in first 24 hours were assessed in each group. RESULTS Verbal Numerical Rating Scale score was significantly reduced in Group A compared to Group B at 2, 4, 6 and 24 hours postoperatively and there was no difference in scores 12 hours postoperatively. Nausea was significantly lower in Group A patients at 2, 4 and 6 hours postoperatively with no difference at 12 and 24 hours postoperatively. There was significant difference in the sedation scale at 4, 6 and 24 hours postoperatively and no difference between both groups at 2 hours and 12 hours postoperatively. Total tramadol requirement in first 24 hours postoperatively was significantly lower in Group A compared to Group B (60.83 ± 14.208 mg Vs. 121.67 ± 19.402 mg, P value< 0.00. CONCLUSION Ultrasound guided TAP block along with standard analgesic care provided better analgesia as compared to standard analgesic care alone in the first 24

  14. Consensus standards utilized and implemented for nuclear criticality safety in Japan

    International Nuclear Information System (INIS)

    Nomura, Yasushi; Okuno, Hiroshi; Naito, Yoshitaka

    1996-01-01

    The fundamental framework for the criticality safety of nuclear fuel facilities regulations is, in many advanced countries, generally formulated so that technical standards or handbook data are utilized to support the licensing safety review and to implement its guidelines. In Japan also, adequacy of the safety design of nuclear fuel facilities is checked and reviewed on the basis of licensing safety review guides. These guides are, first, open-quotes The Basic Guides for Licensing Safety Review of Nuclear Fuel Facilities,close quotes and as its subsidiaries, open-quotes The Uranium Fuel Fabrication Facility Licensing Safety Review Guidesclose quotes and open-quotes The Reprocessing Facility Licensing Safety Review Guides.close quotes The open-quotes Nuclear Criticality Safety Handbook close-quote of Japan and the Technical Data Collection are published and utilized to supply related data and information for the licensing safety review, such as for the Rokkasho reprocessing plant. The well-established technical standards and data abroad such as those by the American Nuclear Society and the American National Standards Institute are also utilized to complement the standards in Japan. The basic principles of criticality safety control for nuclear fuel facilities in Japan are duly stipulated in the aforementioned basic guides as follows: 1. Guide 10: Criticality control for a single unit; 2. Guide 11: Criticality control for multiple units; 3. Guide 12: Consideration for a criticality accident

  15. Topography-modified refraction: adjustment of treated cylinder amount and axis to the topography versus standard clinical refraction in myopic topography-guided LASIK

    OpenAIRE

    Alpins, Noel

    2017-01-01

    Noel Alpins1,2 1NewVision Clinics, Melbourne, VIC, Australia; 2Department Ophthalmology, Melbourne University, Melbourne, VIC, Australia It is encouraging to see the results in the article by Kanellopoulos “Topography-modified refraction (TMR): adjustment of treated cylinder amount and axis to the topography versus standard clinical refraction in myopic topography-guided LASIK”,1 where the combination of refractive and corneal data in the treatment parameters pro...

  16. Standard Guide for Simulation of Helium Effects in Irradiated Metals

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1996-01-01

    1.1 This guide provides advice for conducting experiments to investigate the effects of helium on the properties of metals where the technique for introducing the helium differs in some way from the actual mechanism of introduction of helium in service. Simulation techniques considered for introducing helium shall include charged particle implantation, exposure to α-emitting radioisotopes, and tritium decay techniques. Procedures for the analysis of helium content and helium distribution within the specimen are also recommended. 1.2 Two other methods for introducing helium into irradiated materials are not covered in this guide. They are the enhancement of helium production in nickel-bearing alloys by spectral tailoring in mixed-spectrum fission reactors, and isotopic tailoring in both fast and mixed-spectrum fission reactors. These techniques are described in Refs (1-5). Dual ion beam techniques (6) for simultaneously implanting helium and generating displacement damage are also not included here. This lat...

  17. Standard guide for three methods of assessing buried steel tanks

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1998-01-01

    1.1 This guide covers procedures to be implemented prior to the application of cathodic protection for evaluating the suitability of a tank for upgrading by cathodic protection alone. 1.2 Three procedures are described and identified as Methods A, B, and C. 1.2.1 Method A—Noninvasive with primary emphasis on statistical and electrochemical analysis of external site environment corrosion data. 1.2.2 Method B—Invasive ultrasonic thickness testing with external corrosion evaluation. 1.2.3 Method C—Invasive permanently recorded visual inspection and evaluation including external corrosion assessment. 1.3 This guide presents the methodology and the procedures utilizing site and tank specific data for determining a tank's condition and the suitability for such tanks to be upgraded with cathodic protection. 1.4 The tank's condition shall be assessed using Method A, B, or C. Prior to assessing the tank, a preliminary site survey shall be performed pursuant to Section 8 and the tank shall be tightness test...

  18. Standards development status. Summary report

    International Nuclear Information System (INIS)

    1981-12-01

    The Standards Development Status Summary Report is designed for scheduling, monitoring, and controlling the process by which Regulatory Standards, Guides, Reports, Petitions, and Environmental Statements are written. It is a summary of the current schedule plans for development of the above products

  19. Heat treatment evaluation of steel ASTM A-131 grade A by X-Ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira Junior, Francisco; Feio, Luciana Gaspar; Costa, Ednelson Silva; Rodrigues, Lino Alberto Soares; Braga, Eduardo Magalhaes, E-mail: juniorferrer93@gmail.com [Universidade Federal do Pará (UFPA), Belém, PA (Brazil)

    2016-07-01

    Full text: This study evaluates the residual stress of naval steel ASTM A-131 grade A before and after heat treatment. Residual stresses were determined by the technique of X-ray diffraction (XRD). Before heat treatment the residual stress measurements were made at 36 (thirty six) points distributed in a specimen with dimensions of 400 mm long, 200 mm wide and 95 mm thick, then the plate under analysis was brought to the oven for the implementation of heat treatment. To check the performance of the heat treatment, the plate was again subjected to XRD measurements of the same points previously measured in order to compare the residual stresses. As result, there was a reduction of residual stresses with the application of heat treatment. References: [1] COLPAERT, H. Metalografia dos Produtos Siderurgicos Comuns. 4 Edição. Editora Blucher. Saõ Paulo, SP, 2008. [2] HILL, R. Princípios de Metalurgia Física, 1992. (author)

  20. Standard Guide for Application of Neutron Transport Methods for Reactor Vessel Surveillance, E706 (IID)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 Need for Neutronics Calculations—An accurate calculation of the neutron fluence and fluence rate at several locations is essential for the analysis of integral dosimetry measurements and for predicting irradiation damage exposure parameter values in the pressure vessel. Exposure parameter values may be obtained directly from calculations or indirectly from calculations that are adjusted with dosimetry measurements; Guide E944 and Practice E853 define appropriate computational procedures. 1.2 Methodology—Neutronics calculations for application to reactor vessel surveillance encompass three essential areas: (1) validation of methods by comparison of calculations with dosimetry measurements in a benchmark experiment, (2) determination of the neutron source distribution in the reactor core, and (3) calculation of neutron fluence rate at the surveillance position and in the pressure vessel. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is th...

  1. A multicenter, primary-care-based, open-label study to assess the success of converting opioid-experienced patients with chronic moderate-to-severe pain to morphine sulfate and naltrexone hydrochloride extended-release capsules using a standardized conversion guide.

    Science.gov (United States)

    Setnik, Beatrice; Roland, Carl L; Sommerville, Kenneth W; Pixton, Glenn C; Berke, Robert; Calkins, Anne; Goli, Veeraindar

    2015-01-01

    To evaluate the conversion of opioid-experienced patients with chronic moderate-to-severe pain to extended-release morphine sulfate with sequestered naltrexone hydrochloride (MSN) using a standardized conversion guide. This open-label, single-arm study was conducted in 157 primary care centers in the United States. A total of 684 opioid-experienced adults with chronic moderate-to-severe pain were converted to oral administration of MSN from transdermal fentanyl and oral formulations of hydrocodone, hydromorphone, methadone, oxycodone, oxymorphone, and other morphine products using a standardized conversion guide. The primary endpoint was the percentage of patients achieving a stable MSN dose within a 6-week titration phase. Secondary endpoints included duration of time to stable dose, number of titration steps, safety and efficacy measures, and investigator assessment of conversion guide utility. Of the 684 patients, 51.3% were converted to a stable dose of MSN (95% confidence interval: 47.5%, 55.1%). The mean (standard deviation) number of days to stable dose was 20 (8.94), and number of titration steps to stable dose was 2.4 (1.37). The majority of adverse events were mild/moderate and consistent with opioid therapy. Mean pain scores at stable dose decreased from baseline. Investigators were generally satisfied with the conversion guide and, in 94% of cases, reported they would use it again. Conversion to MSN treatment using the standardized MSN conversion guide was an attainable goal in approximately half of the population of opioid-experienced patients with chronic moderate-to-severe pain. Investigators found the guide to be a useful tool to assist conversion of opioid-experienced patients to MSN.

  2. 45 CFR 162.1202 - Standards for eligibility for a health plan transaction.

    Science.gov (United States)

    2010-10-01

    ... benefit inquiry and response. The ASC X12 Standards for Electronic Data Interchange Technical Report Type... Telecommunication Standard Implementation Guide, Version 5, Release 1 (Version 5.1), September 1999, and equivalent... supporting Telecommunications Standard Implementation Guide, Version 5, Release 1 (Version 5.1) for the NCPDP...

  3. Gas chromatographic sulphur speciation in heavy crude oil using a modified standard D5623 method and microfluidic Deans switching.

    Science.gov (United States)

    Heshka, Nicole E; Choy, Joanne M; Chen, Jinwen

    2017-12-29

    A modification to American Society for Testing and Materials (ASTM) method D5623 is proposed to enable successful and repeatable analysis of heavy crude oil samples. A two-dimensional gas chromatography configuration was implemented, with separation of sulphur compounds occurring on two columns. A Deans switch is used to enable heart-cutting of volatile sulphur compounds onto a DB-Sulfur stationary phase, and separation occurs concurrently with the backflushing of the primary column. The use of a sulphur-selective detector increases selectivity, and 22 volatile sulphur species are quantified in less than 15min, which is almost half the time of the original ASTM method. Samples ranging from light distillation cuts to whole crudes (boiling from 100°C to >750°C) were analyzed with minimal sample preparation. The calculated limit of detection was 0.7mg/kg, repeatability was 3% relative standard deviation (RSD), and a linear range of 1-250mg/kg was obtained, with an R 2 value of 0.994 or better, depending on the compound. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  4. 40 CFR 90.7 - Reference materials.

    Science.gov (United States)

    2010-07-01

    .... ASTM D3231-89: Standard Test Method for Phosphorus in Gasoline Appendix A to subpart D, Table 3. ASTM D3606-92: Standard Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation... 770141, Optimization of a Flame Ionization Detector for Determination of Hydrocarbon in Diluted...

  5. Culinary Arts Hospitality Symposium Planning Guide.

    Science.gov (United States)

    Borgie, Karen; Wang, Yeimei

    This guide was developed as part of a project to standardize California's statewide culinary arts curriculum based on industry guidelines and standards. It details a process that California community colleges can use to plan a hospitality symposium that will accomplish the following objectives: provide students with a forum to demonstrate their…

  6. Designing and conducting survey research a comprehensive guide

    CERN Document Server

    Rea, Louis M

    2014-01-01

    The industry standard guide, updated with new ideas and SPSS analysis techniques Designing and Conducting Survey Research: A Comprehensive Guide Fourth Edition is the industry standard resource that covers all major components of the survey process, updated to include new data analysis techniques and SPSS procedures with sample data sets online. The book offers practical, actionable guidance on constructing the instrument, administrating the process, and analyzing and reporting the results, providing extensive examples and worksheets that demonstrate the appropriate use of survey and data tech

  7. Avaliação das propriedades termo-mecânicas de borracha nitrílica após ensaio de compatibilidade de acordo com ASTM D 3455 Thermal-mechanical properties evaluation of nitrilic rubber after compatibility test according to ASTM D 3455

    Directory of Open Access Journals (Sweden)

    Adailze L. Meyer

    2006-01-01

    Full Text Available O copolímero butadieno - acrilonitrila - NBR é comumente aplicado na confecção de gaxetas e anéis de vedação para transformadores elétricos isolados a óleo mineral. Durante o uso esses materiais permanecem em contato com óleo em temperaturas próximas a 90 ºC provocando alterações físicas e químicas no material elastomérico e no óleo. Neste trabalho, estudou-se a variação das propriedades mecânicas do elastômero resultantes do ensaio de compatibilidade (ASTM D 3455[3]. A caracterização mecânica foi realizada por ensaios de resistência a tração, dureza e análise dinâmico-mecânica (DMA. A verificação da estabilidade térmica e a composição do NBR foram obtidas através de análise termogravimétrica (TGA.The copolymer of acrylonitrile and butadiene - NBR is commonly used to manufacture gaskets and seals to be used in electrical transformers insulated by mineral oil. During operation those materials are constantly in contact with oil at temperatures that can reach 90 ºC, causing physical and chemicals changes in both gaskets and oil. In this paper the changes in elastomer mechanical properties after the compatibility test were studied (ASTM D 3455[3]. This characterization was done by tension properties, hardness and dynamical mechanical analysis (DMA. The evaluation of thermal stability and composition of the NBR was carried out through thermogravimetry analysis (TG.

  8. Application of Response Surface Methodology for Modeling of Postweld Heat Treatment Process in a Pressure Vessel Steel ASTM A516 Grade 70.

    Science.gov (United States)

    Peasura, Prachya

    2015-01-01

    This research studied the application of the response surface methodology (RSM) and central composite design (CCD) experiment in mathematical model and optimizes postweld heat treatment (PWHT). The material of study is a pressure vessel steel ASTM A516 grade 70 that is used for gas metal arc welding. PWHT parameters examined in this study included PWHT temperatures and time. The resulting materials were examined using CCD experiment and the RSM to determine the resulting material tensile strength test, observed with optical microscopy and scanning electron microscopy. The experimental results show that using a full quadratic model with the proposed mathematical model is YTS = -285.521 + 15.706X1 + 2.514X2 - 0.004X1(2) - 0.001X2(2) - 0.029X1X2. Tensile strength parameters of PWHT were optimized PWHT time of 5.00 hr and PWHT temperature of 645.75°C. The results show that the PWHT time is the dominant mechanism used to modify the tensile strength compared to the PWHT temperatures. This phenomenon could be explained by the fact that pearlite can contribute to higher tensile strength. Pearlite has an intensity, which results in increased material tensile strength. The research described here can be used as material data on PWHT parameters for an ASTM A516 grade 70 weld.

  9. Evolution. Teacher's Guide.

    Science.gov (United States)

    Bershad, Carol

    This teacher's guide was developed to assist teachers in the use of multimedia resources for the Public Broadcasting System (PBS) program, "Evolution." Each unit uses an inquiry-based approach to meet the National Science Education Standards. Units include: (1) "What is the Nature of Science?"; (2) "Who Was Charles Darwin?"; (3) "What is the…

  10. Standardized Curriculum for Service Station Retailing.

    Science.gov (United States)

    Mississippi State Dept. of Education, Jackson. Office of Vocational, Technical and Adult Education.

    This curriculum guide for service station retailing was developed by the state of Mississippi to standardize vocational education course titles and core contents. The objectives contained in this document are common to all service station retailing programs in the state. The guide contains objectives for service station retailing I and II courses.…

  11. FY 2000 Project of developing international standards for supporting new industries. 'Standardization of multicolor measurement'; 2000 nendo shinki sangyo shiengata kokusai hyojun kaihatsu jigyo seika hokokusho. Multicolor no sokushoku no hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Described herein are the FY 2000 results of the study on and research and development of the testing methods for tones of anisotropic color materials (multi-colors) for proposing the international standard. USA has proposed the triangle colorimetry, based on the results of the visual tests with metallic paints, which is being incorporated in the ASTM standards. Germany seems to adopt the multi-angle colorimetery in the DIN standards. The FY 2000 efforts are directed to measurement of the reflection characteristics of the metallic and pearl-mica samples by a variable-angle spectrophotometer. The solid color and metallic color are being evaluated by a weather resistance tester QUV and outdoor tests, because of the anticipated different mechanisms by which they are aged. The functional test and analysis are also required to correlate the multi-color measurement results with visual evaluation results, and the preliminary tests are conducted to improve skill of the panelists. (NEDO)

  12. Hydrogen embrittlement of ASTM A 203 D nuclear structural steel

    International Nuclear Information System (INIS)

    Chakravartty, J.K.; Prasad, G.E.; Sinha, T.K.; Asundi, M.K.

    1986-01-01

    The influence of hydrogen on the mechanical properties of ASTM A 203 D nuclear structural steel has been studied by tension, bend and delayed-failure tests at room temperature. While the tension tests of hydrogen charged unnotched specimens reveal no change in ultimate strength and ductility, the effect of hydrogen is manifested in notched specimens (tensile and bend) as a decrease in ultimate strength (maximum load in bend test) and ductility; the effect increases with increasing hydrogen content. It is observed that for a given hydrogen concentration, the decrease in bend ductility is remarkably large compared to that in tensile ductility. Hydrogen charging does not cause any delayed-failure upto 200 h under an applied tensile stress, 0.85 times the notch tensile strength. However delayed failure occurs in hydrogen charged bend samples in less than 10 h under an applied bending load of about 0.80 times of the uncharged maximum load. Fractographs of hydrogen charged unnotched specimens show ductile dimple fracture, while those of notched tension and bend specimens under hydrogen-charged conditions show a mixture of ductile dimple and quasi-cleavage cracking. The proportion of quasi-cleavage cracking increases with increasing hydrogen content and this fracture mode is more predominant in bend specimens. The changes in tensile properties and fracture modes can reasonably be explained by existing theories of hydrogen embrittlement. An attempt is made to explain the significant difference in the embrittlement susceptibility of bend and tensile specimens in the light of difference in triaxiality and plastic zone size near the notch tip. (orig.)

  13. Method validation for uranium content analysis using a potentiometer T-90

    International Nuclear Information System (INIS)

    Torowati; Ngatijo; Rahmiati

    2016-01-01

    An experimental method validation has been conducted for uranium content analysis using Potentiometer T-90. The method validation experiment was performed in the quality control laboratory of Experiment Fuel Element Installation, PTBBN - BATAN. The objective is to determine the level of precision and accuracy of analytical results for uranium analysis referring to the latest American Standard Test Method (ASTM) of ASTM C1267-11, which is a modified reference method by reducing of reagent consumption by 10% of the amount used by the original method. The ASTM C 1267-11 reference is a new ASTM as a substitute for the older ASTM namely ASTM C799, Vol.12.01, 2003. It is, therefore, necessary to validate the renewed method. The tool used for the analysis of uranium was potentiometer T-90 and the material used was standard uranium oxide powder CRM (Certificate Reference Material). Validation of the method was done by analyzing standard uranium powder by 7 times weighing and 7 times analysis. Analysis results were used to determine the level of accuracy, precision, Relative Standard Deviation (RSD) and Horwitz coefficient Variation and limit detection and quantitation. The average uranium obtained for this method validation is 84.36% with Standard Deviation (SD) of 0.12%, Relative Standard Deviation (RSD) 0.14% and 2/3 Horwitz coefficient Variation (CV Horwitz) 2.05%. The results show that RSD value is smaller than the value of (2/3) CV Horwitz, which means that this method has a high precision. The accuracy value obtained is 0.48%, and since the acceptance limit of high level of accuracy is when the accuracy value is <2.00%, this method is regarded as having a high degree of accuracy [1]. The limit of detection (LOD) and and the limit of quantitation (LOQ) are 0.0145 g/L and 0.0446 g/L respectively. It is concluded that the ASTM C 1267-11 reference method is valid for use. (author)

  14. Investigating the effect of coil model losses on computational electromagnetic exposure of an ASTM phantom at 64 MHz MRI.

    Science.gov (United States)

    Kozlov, Mikhail; Horner, Marc; Kainz, Wolfgang; Angelone, Leonardo M

    2017-07-01

    The goal of this work is to investigate the effect of coil losses on the electromagnetic field generated in an ASTM phantom by a birdcage coil. The study was based on different numerical implementations of an RF body coil at 64 MHz, using the same 3D EM and RF circuit co-simulation procedure. The coil quality factor was evaluated with respect to losses due to power feed mismatch and to resistive losses of the coil components. The results of the study showed that the magnetic field at the coil iso-center, normalized to the square root of the whole body specific absorption rate, depends on the coil quality factor.

  15. Fuel and Fuel System Materials Compatibility Test Program for A JP-8+100 Fuel Additive. Volume 1: Thermal Stability Additive Package BetzDearborn Spec Aid(Registered) 8Q462

    Science.gov (United States)

    2001-10-01

    SAE Rings, Sealing, Butadiene-Acrylonitrile ( NBR ), Rubber Fuel and Low Temperature Resistant 60 - 70 MIL-R-83248C Rubber , Fluorocarbon...KAPTON/TEFLON (COMPOSITE) WIRE I.I.10 34 VI. REFERENCE DOCUMENTS Non-Metallics MIL-HDBK-149B Military Standardization Hand Book Rubber ...ASTM D-1414 Standard Test Methods for Rubber O-Rings ASTM D-412 Type II Standard Test Methods for Vulcanized Rubber and Thermoplastic

  16. Next-generation services for e-traceability to ionizing radiation national standards

    International Nuclear Information System (INIS)

    Desrosiers, M.F.; Klemick, Mark; Puhl, J.M.; Uchida, David; Mallis, Steven

    2004-01-01

    An Internet-based system for fast, remote certification of high-dose radiation sources against the US national standard is being constructed at the National Institute of Standards and Technology (NIST). The new service will establish traceability (through transfer dosimetry) in real time at a lower cost by using automated routines and the Internet. A prototype of this service was successfully demonstrated in 2000 at the American Society for Testing and Materials (ASTM) Dosimetry Workshop in San Diego. Despite this impressive accomplishment, new developments demanded that several aspects of the service be modified. The new service has been completely redesigned to address these new demands and ensure greater accessibility. A description of the hardware and software configurations of this service as well as the communication and information management aspects will be presented. The Internet-based transfer certification program will provide industry with 24-h, 7-day-per-week, on-demand certifications, immediate turnaround times, and lower cost, ultimately improving the quality of the manufacturing process

  17. Next-generation services for e-traceability to ionizing radiation national standards

    Science.gov (United States)

    Desrosiers, Marc F.; Klemick, Mark; Puhl, James M.; Uchida, David; Mallis, Steven

    2004-09-01

    An Internet-based system for fast, remote certification of high-dose radiation sources against the US national standard is being constructed at the National Institute of Standards and Technology (NIST). The new service will establish traceability (through transfer dosimetry) in real time at a lower cost by using automated routines and the Internet. A prototype of this service was successfully demonstrated in 2000 at the American Society for Testing and Materials (ASTM) Dosimetry Workshop in San Diego. Despite this impressive accomplishment, new developments demanded that several aspects of the service be modified. The new service has been completely redesigned to address these new demands and ensure greater accessibility. A description of the hardware and software configurations of this service as well as the communication and information management aspects will be presented. The Internet-based transfer certification program will provide industry with 24-h, 7-day-per-week, on-demand certifications, immediate turnaround times, and lower cost, ultimately improving the quality of the manufacturing process.

  18. 46 CFR 193.01-3 - Incorporation by reference.

    Science.gov (United States)

    2010-10-01

    ... http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. Also, it is... Conshohocken, PA 19428-2959, telephone 610-832-9585, http://www.astm.org. (1) ASTM F 1121-87 (1993), Standard... Park, Quincy, MA 02269-9101, telephone 800-344-3555, http://www.nfpa.org. (1) NFPA 13-1996, Standard...

  19. 46 CFR 95.01-2 - Incorporation by reference.

    Science.gov (United States)

    2010-10-01

    ... http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. Also, it is..., PA 19428-2959, telephone 610-832-9585, http://www.astm.org. (1) ASTM F 1121-87 (1993), Standard... Park, Quincy, MA 02269-9101, telephone 800-344-3555, http://www.nfpa.org. (1) NFPA 13-1996, Standard...

  20. 46 CFR 34.01-15 - Incorporation by reference.

    Science.gov (United States)

    2010-10-01

    ... availability of this material at NARA, call 202-741-6030 or go to http://www.archives.gov/federal_register/code..., http://www.astm.org. (1) ASTM F 1121-87 (Reapproved 1993), Standard Specification for International...-9101, telephone 800-344-3555, http://www.nfpa.org. (1) NFPA 13-1996, Standard for the Installation of...

  1. PCI DSS a practical guide to implementing and maintaining compliance

    CERN Document Server

    Wright, Steve

    2011-01-01

    This newly revised, practical guide, gives you a step by step guide to achieving Payment Card Industry Data Security Standard (PCI DSS) compliance - showing you how to create, design and build a PCI compliance framework.

  2. Making It Happen: Common Core Standards

    Science.gov (United States)

    National Council of Teachers of Mathematics, 2011

    2011-01-01

    This one-of-a-kind guide identifies and highlights the ways in which NCTM (National Council of Teachers of Mathematics) resources can support teachers as they implement and supplement the Common Core State Standards for Mathematics (CCSSM) in their states. The guide and accompanying charts are tools to help educators as they continue to make…

  3. Adobe Edge Quickstart Guide

    CERN Document Server

    Labrecque, Joseph

    2012-01-01

    Adobe Edge Quickstart Guide is a practical guide on creating engaging content for the Web with Adobe's newest HTML5 tool. By taking a chapter-by-chapter look at each major aspect of Adobe Edge, the book lets you digest the available features in small, easily understandable chunks, allowing you to start using Adobe Edge for your web design needs immediately. If you are interested in creating engaging motion and interactive compositions using web standards with professional tooling, then this book is for you. Those with a background in Flash Professional wanting to get started quickly with Adobe

  4. Standard Guide for Post-Deactivation Surveillance and Maintenance of Radiologically Contaminated Facilities

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This guide outlines a method for developing a Surveillance and Maintenance (S&M) plan for inactive nuclear facilities. It describes the steps and activities necessary to prevent loss or release of radioactive or hazardous materials, and to minimize physical risks between the deactivation phase and the start of facility decontamination and decommissioning (D&D). 1.2 The primary concerns for S&M are related to (1) animal intrusion, (2) structural integrity degradation, (3) water in-leakage, (4) contamination migration, (5) unauthorized personnel entry, and (6) theft/intrusion. This document is intended to serve as a guide only, and is not intended to modify existing regulations.

  5. Standard test method for tension testing of structural alloys in liquid helium

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method describes procedures for the tension testing of structural alloys in liquid helium. The format is similar to that of other ASTM tension test standards, but the contents include modifications for cryogenic testing which requires special apparatus, smaller specimens, and concern for serrated yielding, adiabatic heating, and strain-rate effects. 1.2 To conduct a tension test by this standard, the specimen in a cryostat is fully submerged in normal liquid helium (He I) and tested using crosshead displacement control at a nominal strain rate of 10−3 s−1 or less. Tests using force control or high strain rates are not considered. 1.3 This standard specifies methods for the measurement of yield strength, tensile strength, elongation, and reduction of area. The determination of the elastic modulus is treated in Test Method E 111. Note 1—The boiling point of normal liquid helium (He I) at sea level is 4.2 K (−269°C or −452.1°F or 7.6°R). It decreases with geographic elevation and is...

  6. DEVELOPING STANDARDS FOR ASSESSING ENVIRONMENTAL CHEMICAL, PHYSICAL, AND BIOLOGICAL STRESSORS THROUGH ASTM COMMITTEE E47: A PAST FOUNDATION OF PROVEN STANDARDS, A FUTURE OF GREAT POTENTIAL AND OPPORTUNITY

    Science.gov (United States)

    Development of standards associated with assessing the bioavailability of contaminants in sediment will be used as a case study for how standards have been developed through Committee E47. In 1987, Committee E47 established Subcommittee E47.03 on Sediment Assessment and Toxicity....

  7. SEAPOWER: A GUIDE FOR THE TWENTY- FIRST CENTURY

    African Journals Online (AJOL)

    Abel

    $154,37 (amazon.com hardback). With the publication of Seapower: A Guide for the Twenty-First Century. Geoffrey Till has set the standard for publications on all things maritime. The updated and expanded new edition of the book is an essential guide for students of naval history and maritime strategy and provides ...

  8. Intelligence Level Performance Standards Research for Autonomous Vehicles.

    Science.gov (United States)

    Bostelman, Roger B; Hong, Tsai H; Messina, Elena

    2015-01-01

    United States and European safety standards have evolved to protect workers near Automatic Guided Vehicles (AGV's). However, performance standards for AGV's and mobile robots have only recently begun development. Lessons can be learned from research and standards efforts for mobile robots applied to emergency response and military applications. Research challenges, tests and evaluations, and programs to develop higher intelligence levels for vehicles can also used to guide industrial AGV developments towards more adaptable and intelligent systems. These other efforts also provide useful standards development criteria for AGV performance test methods. Current standards areas being considered for AGVs are for docking, navigation, obstacle avoidance, and the ground truth systems that measure performance. This paper provides a look to the future with standards developments in both the performance of vehicles and the dynamic perception systems that measure intelligent vehicle performance.

  9. Effects of thermal treatments on protein adsorption of Co-Cr-Mo ASTM-F75 alloys.

    Science.gov (United States)

    Duncan, L A; Labeed, F H; Abel, M-L; Kamali, A; Watts, J F

    2011-06-01

    Post-manufacturing thermal treatments are commonly employed in the production of hip replacements to reduce shrinkage voids which can occur in cast components. Several studies have investigated the consequences of these treatments upon the alloy microstructure and tribological properties but none have determined if there are any biological ramifications. In this study the adsorption of proteins from foetal bovine serum (FBS) on three Co-Cr-Mo ASTM-F75 alloy samples with different metallurgical histories, has been studied as a function of protein concentration. Adsorption isotherms have been plotted using the surface concentration of nitrogen as a diagnostic of protein uptake as measured by X-ray photoelectron spectroscopy. The data was a good fit to the Langmuir adsorption isotherm up to the concentration at which critical protein saturation occurred. Differences in protein adsorption on each alloy have been observed. This suggests that development of the tissue/implant interface, although similar, may differ between as-cast (AC) and heat treated samples.

  10. Tekken tests in a steel 'ASTM A 514 GR B' to determine the preheating temperature

    International Nuclear Information System (INIS)

    Quesada, Hector Juan; Zalazar, Monica; Asta, Eduardo Pablo

    2004-01-01

    Cold fissure tests are used to determine the proper preheating temperature in order to prevent fissures during the steel welding process. Tekken tests were carried out on a quenched and tempered high resistance 25.4 mm thick steel (ASTM A514 Gr.B) used in structural applications. The welding was carried out using a FCAW semiautomatic process with gas protection and low hydrogen tubular electrode E110T5-K4. Similar parameters and splicing design were later applied in production. The microstructures of the base material and the welding were determined by optic and electron microscopy. The thermal cycles of the welding were recorded in order to relate the preheating temperature with the cooling time from 800 o C - 500 o C (t 8/5 ) and from 800 o C - 100 o C (tg/1) and the presence or not of fissures. Preheating at 150 o C and t 8/5 greater than 17 s was found to guarantee fissure free welding (CW)

  11. Tekken testing to determine the preheating temperature on ASTM A514 GR B steel

    International Nuclear Information System (INIS)

    Asta, Eduardo; Zalazar, Monica; Quesada, Hector

    2003-01-01

    The cold cracking test methods are used to determine the preheating temperature in order to avoid cracking in steel welding.In this work Tekken tests on high strength quenching and tempering (ASTM A514 GrB) structural steel with a thickness of 25 mm have been made.The welds were done using a FCAW process with gas shielding and basic low hydrogen cored wire E 110T5-K4.The welding parameters and joint design applied in this work are similar to the ones used on site production.The base metal, HAZ and weld metal microstructure have been evaluated by optical and SEM microscopy.Thermal cycles records of each welding have been made to relate preheat temperature with the cooling time on the range of 800-500 degC (t8/5) or 800-100degC (t8/1) and the evidence of crack or no crack condition.Finally, a preheat temperature of 150degC and the cooling time larger than 17 s improve a welding integrity without cracks

  12. COMPETITION BEETWEN DYNAMIC RECUPERATION AND RECRYSTALLIZATION OF ASTM F 138 AUSTENITIC STAINLESS STEEL UTILIZED IN MEDICAL DEVICES

    Directory of Open Access Journals (Sweden)

    Fabio Henrique Casarini Geronimo

    2013-06-01

    Full Text Available ASTM F 138 austenitic stainless steel has being used in the manufacture of orthopedical devices by hot forging. In this work, the flow stress curves are determined by hot torsion tests in a wide range of temperatures and strain rates. With the observed microestrutural evolution by optical microscopy in different hot forming conditions in addiction with EBSD (Electron Backscatter Diffraction techniques it is possible to obtained the recrystallized volume fraction and the misorientation angles of the samples. Due to the intermediate level of stacking fault energy of this material, during the dynamic softening occurs a competition between recrystallization and recovery. The aim of this work is to identify the softening mechanisms in this stainless steel, as well as in which hot work conditions they become more active.

  13. Automated acid and base number determination of mineral-based lubricants by fourier transform infrared spectroscopy: commercial laboratory evaluation.

    Science.gov (United States)

    Winterfield, Craig; van de Voort, F R

    2014-12-01

    The Fluid Life Corporation assessed and implemented Fourier transform infrared spectroscopy (FTIR)-based methods using American Society for Testing and Materials (ASTM)-like stoichiometric reactions for determination of acid and base number for in-service mineral-based oils. The basic protocols, quality control procedures, calibration, validation, and performance of these new quantitative methods are assessed. ASTM correspondence is attained using a mixed-mode calibration, using primary reference standards to anchor the calibration, supplemented by representative sample lubricants analyzed by ASTM procedures. A partial least squares calibration is devised by combining primary acid/base reference standards and representative samples, focusing on the main spectral stoichiometric response with chemometrics assisting in accounting for matrix variability. FTIR(AN/BN) methodology is precise, accurate, and free of most interference that affects ASTM D664 and D4739 results. Extensive side-by-side operational runs produced normally distributed differences with mean differences close to zero and standard deviations of 0.18 and 0.26 mg KOH/g, respectively. Statistically, the FTIR methods are a direct match to the ASTM methods, with superior performance in terms of analytical throughput, preparation time, and solvent use. FTIR(AN/BN) analysis is a viable, significant advance for in-service lubricant analysis, providing an economic means of trending samples instead of tedious and expensive conventional ASTM(AN/BN) procedures. © 2014 Society for Laboratory Automation and Screening.

  14. Standard specification for deuterium oxide

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Minimum requirements are set forth for D 2 O to be used as a moderator in heavy water moderated reactors. Requirements are specified for isotopic content, electrical conductivity, consumption of KMnO 4 , turbidity, total solids, and chlorides. ASTM test methods are cited for the determination of each of these requirements

  15. 40 CFR 264.1101 - Design and operating standards.

    Science.gov (United States)

    2010-07-01

    ... the American Concrete Institute (ACI) and the American Society of Testing Materials (ASTM) in judging... they are exposed; climatic conditions; and the stresses of daily operation, including the movement of...

  16. 78 FR 38739 - Standard Format and Content for Post-Shutdown Decommissioning Activities Report

    Science.gov (United States)

    2013-06-27

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0299] Standard Format and Content for Post-Shutdown Decommissioning Activities Report AGENCY: Nuclear Regulatory Commission. ACTION: Regulatory guide; issuance..., ``Standard Format and Content for Post-shutdown Decommissioning Activities Report.'' This guide describes a...

  17. 76 FR 13631 - Food and Drug Administration Modernization Act of 1997: Modifications to the List of Recognized...

    Science.gov (United States)

    2011-03-14

    ... (Reapproved 2008). Ultra-High Molecular Weight Polyethylene Used in Surgical Implants. F. Nanotechnology 18-1... equipment. I. Tissue Engineering 15-25 ASTM F2312--10 Standard ASTM F2312-10. Terminology Relating to Tissue...

  18. 炭素繊維複合材料に対する無孔圧縮試験方法の相互比較と簡便な試験法(NAL-II法)の提案

    OpenAIRE

    Ogasawara, Toshio; Ishikawa, Takashi; 小笠原, 俊夫; 石川, 隆司

    2009-01-01

    A specific non-hole compressive (NHC) test method for advanced composite materials has not been widely authorized even now because of the essential difficulty of NHC tests. In this study, standard test methods such as SRM-1 (SACMA), Celanese (former ASTM D3410 A-method), ASTM D695, ASTM D6484 (SRM-3), ASTM D6641 (CLC), JIS K7076 (A method) were evaluated for three kinds of quasi-isotropic carbon/epoxy composites (CFRP). Furthermore, two kinds of original compressive test methods, i.e.NAL-I, I...

  19. WWC Study Review Guide: Group Design Studies

    Science.gov (United States)

    What Works Clearinghouse, 2018

    2018-01-01

    Underlying all What Works Clearinghouse (WWC) products are WWC Study Review Guides, which are intended for use by WWC certified reviewers to assess studies against the WWC evidence standards. As part of an ongoing effort to increase transparency, promote collaboration, and encourage widespread use of the WWC standards, the Institute of Education…

  20. Civil Engineering Technology Program Guide.

    Science.gov (United States)

    Georgia Univ., Athens. Dept. of Vocational Education.

    This program guide presents civil engineering technology curriculum for technical institutes in Georgia. The general information section contains the following: purpose and objectives; program description, including admissions, typical job titles, and accreditation and certification; and curriculum model, including standard curriculum sequence and…

  1. 40 CFR 265.1101 - Design and operating standards.

    Science.gov (United States)

    2010-07-01

    ... industry such as the American Concrete Institute (ACI) and the American Society of Testing Materials (ASTM... wastes to which they are exposed; climatic conditions; and the stresses of daily operation, including the...

  2. A user's manual to the PMBOK guide

    CERN Document Server

    Stackpole Snyder, Cynthia

    2013-01-01

    The must-have manual to understand and use the latest edition of the Fifth Edition The professional standard in the field of project management, A Guide to the Project Management Body of Knowledge (PMBOK® Guide-Fifth Edition) published by the Project Management Institute (PMI) serves as the ultimate resource for professionals and as a valuable studying and training device for students taking the PMP® Exam. A User''s Manual to the PMBOK® Guide takes the next logical step to act as a true user''s manual. With an accessible format and easy-to-understand language, it helps to not only distill es

  3. Computer program for obtaining thermodynamic and transport properties of air and products of combustion of ASTM-A-1 fuel and air

    Science.gov (United States)

    Hippensteele, S. A.; Colladay, R. S.

    1978-01-01

    A computer program for determining desired thermodynamic and transport property values by means of a three-dimensional (pressure, fuel-air ratio, and either enthalpy or temperature) interpolation routine was developed. The program calculates temperature (or enthalpy), molecular weight, viscosity, specific heat at constant pressure, thermal conductivity, isentropic exponent (equal to the specific heat ratio at conditions where gases do not react), Prandtl number, and entropy for air and a combustion gas mixture of ASTM-A-1 fuel and air over fuel-air ratios from zero to stoichiometric, pressures from 1 to 40 atm, and temperatures from 250 to 2800 K.

  4. Procurement Contracting Officer’s Guide to Cost Accounting Standards,

    Science.gov (United States)

    1977-09-01

    ACCESSION MO r P.R0CUR2K2NT CONTRACTING ^FFICDR’S %UID2 TO COST ACCOUNTING STANDARDS. .-IB’ i 4fiSj irPBVPWra ONOANIZATION NAME MB AOONESS...discussing the history and development of Cost Accounting Standards, the functions of the Cost Accounting Standards Board, and the methodology...20. Abstract (continued) the tasks that Cost Accounting Standards have placed on the procurement officer. 3y understanding these tasks the

  5. A new U.S. film system classification and image quality assessment

    International Nuclear Information System (INIS)

    Knell, M.

    1996-01-01

    The last ASTM Standard E94 which classified Industrial Radiography films was published in 1984. Since that time inspection contracts in US and worldwide have continued to specify Type 1 and Type 2 films--although these no longer exist. From 1990 there was discussion within ASTM and work was done by ASTM Committee E07-01. The method proposed used data on graininess and gradient to produce an index to represent quality. In the early version the author found that it was possible to have a very fine grain low-contrast film with the same index as a fine grain film, with high contrast. The draft standard was then developed, so that it is possible to classify both types of film in separate groups. The first is the Classical type of film and the second is a Wide Latitude film. In a Classical film, the contrast increases over the useable density range. The range of application standards specify densities generally from D = 2.0 to D = 4.0. A radiologist would expect contrast to be higher at D = 4.0 compared with contrast at D = 2.0. The new ASTM film classification uses a signal to noise ratio--with minimum values for each class for contrast and a maximum value for graininess. The ASTM Classification System uses the same parameters as the European Standard EN584-1 and ISO CD

  6. Catalogue of standards at the Safety Analysis department library, the first of March 1987

    International Nuclear Information System (INIS)

    1987-01-01

    This report is a compilation of ANS and ANSI/ANS, ANSI/ASME american standards, Regulatory guides (Power Reactor Division), IEEE standards, to which are added ANSI american standards, AFNOR french standards, all of them being updated until to day. This computed compilation is divided into three parts: 1) main descriptor categories; 2) list of american standards in chronological order, list of AFNOR french standards, list of Regulatory guides in numerical order. 3) list of descriptors in alphabetic order [fr

  7. Standardized reactors for the study of medical biofilms: a review of the principles and latest modifications.

    Science.gov (United States)

    Gomes, Inês B; Meireles, Ana; Gonçalves, Ana L; Goeres, Darla M; Sjollema, Jelmer; Simões, Lúcia C; Simões, Manuel

    2018-08-01

    Biofilms can cause severe problems to human health due to the high tolerance to antimicrobials; consequently, biofilm science and technology constitutes an important research field. Growing a relevant biofilm in the laboratory provides insights into the basic understanding of the biofilm life cycle including responses to antibiotic therapies. Therefore, the selection of an appropriate biofilm reactor is a critical decision, necessary to obtain reproducible and reliable in vitro results. A reactor should be chosen based upon the study goals and a balance between the pros and cons associated with its use and operational conditions that are as similar as possible to the clinical setting. However, standardization in biofilm studies is rare. This review will focus on the four reactors (Calgary biofilm device, Center for Disease Control biofilm reactor, drip flow biofilm reactor, and rotating disk reactor) approved by a standard setting organization (ASTM International) for biofilm experiments and how researchers have modified these standardized reactors and associated protocols to improve the study and understanding of medical biofilms.

  8. Hearing aid user guides: suitability for older adults.

    Science.gov (United States)

    Caposecco, Andrea; Hickson, Louise; Meyer, Carly

    2014-02-01

    The aim of this study was to analyse the content, design, and readability of printed hearing aid user guides to determine their suitability for older adults, who are the main users of hearing aids. Hearing aid user guides were assessed using four readability formulae and a standardized tool to assess content and design (SAM - Suitability Assessment of Materials). A sample of 36 hearing aid user guides (four user guides from nine different hearing aid manufacturers) were analysed. Sixty nine percent of user guides were rated 'not suitable' and 31% were rated 'adequate' for their suitability. Many scored poorly for scope, vocabulary, aspects of layout and typography, and learning stimulation and motivation. The mean reading grade level for all user guides was grade 9.6 which is too high for older adults. The content, design, and readability of hearing aid user guides are not optimal for older adults and thus may serve as a barrier to successful hearing aid outcomes for this population.

  9. Recent activities on nuclear codes and standards

    International Nuclear Information System (INIS)

    Minematsu, Akiyoshi; Ishimoto, Shozaburo; Honjin, Masao

    2000-01-01

    The technical codes and standards relating to the nuclear power stations in Japan are prepared by shapes of laws (ministerial ordinances and bulletins) issued by the government and obliged to comply with by 'the Law concerning the Regulations of Nuclear Material Substances, Nuclear Fuel Substances and Nuclear Reactors' and 'the Electricity Business Act' and of guides defined by the Nuclear Safety Commission, and further some private standards have been issued at a shape of complement of these laws and guides by receiving national recommendation. On the other hand, in the fields of electricity and heat facilities except atomic energy, simplification and feature stipulation of the national technical codes and standards was recently carried out, by which a system usable for the private standards in and out of Japan were prepared through approval of the private Japan Electrotechnical Standards and Codes Committee (JESC). As the nuclear field was now excepted from simultaneous transfer to the private standard and the standard application system, it is expected in future to realize similar transfer if possible and preparation of the private standards is now being advanced. Here were introduced on present state on technical codes and standards relating to the nuclear power generation facilities and recent trends on their private standardization. (G.K.)

  10. A case of standardization?

    DEFF Research Database (Denmark)

    Rod, Morten Hulvej; Høybye, Mette Terp

    2016-01-01

    the ones envisioned by the makers of standards. In 2012, the Danish National Health Authorities introduced a set of health promotion guidelines that were meant to guide the decision making and priority setting of Denmark's 98 local governments. The guidelines provided recommendations for health promotion...... and standardization. It remains an open question whether or not the guidelines lead to more standardized policies and interventions, but we suggest that the guidelines promote a risk factor-oriented approach as the dominant frame for knowledge, reasoning, decision making and priority setting in health promotion. We...

  11. 46 CFR 56.01-2 - Incorporation by reference.

    Science.gov (United States)

    2010-10-01

    ... Welded Ferritic and Martensitic Stainless Steel Tubing for General Service (“ASTM A 268”), 56.60-1; (21) ASTM A 276-98, Standard Specification for Stainless Steel Bars and Shapes (“ASTM A 276”), 56.60-2; (22... (27) ASME B36.19M-2004 Stainless Steel Pipe (2004) (“ASME B36.19M”), 56.07-5; 56.60-1. (28) ASME SA...

  12. Laboratory Evaluation of Light Obscuration Particle Counter Contamination Limits for Aviation Fuel

    Science.gov (United States)

    2015-11-01

    assurance testing though conducting periodic fuel sampling for gravimetric analysis. The Army currently utilizes two methods for measuring particulate...contamination by gravimetric analysis: ASTM D2276 - Standard Test Method for Particulate Contaminant in Aviation Fuel by Line Sampling, and ASTM D5452...while filter effectiveness is checked every 30 days by gravimetric analysis (ASTM D2276). One of the problems with the gravimetric methods is the

  13. Laboratory Evaluation of Light Obscuration Particle Counters used to Establish use Limits for Aviation Fuel

    Science.gov (United States)

    2015-12-01

    The Army currently utilizes two methods for measuring particulate contamination by gravimetric analysis: ASTM D2276 - Standard Test Method for...is checked every 30 days by gravimetric analysis (ASTM D2276). One of the problems with the gravimetric methods is the poor repeatability and...ASTM D2276 testing is an artifact of that method . The correlation of particle counter data to the theoretical gravimetric concentration, and cross

  14. Design Guide for Category I reactors critical facilities

    International Nuclear Information System (INIS)

    Brynda, W.J.; Powell, R.W.

    1978-08-01

    The purpose of this Design Guide is to provide additional guidance to aid the DOE facility contractor in meeting the requirement that the siting, design, construction, modification, operation, maintenance, and decommissioning of DOE-owned critical facilities be in accordance with generally uniform standards, guides, and codes which are comparable to those applied to similar reactors licensed by the Nuclear Regulatory Commission

  15. Standard guide for preparing and interpreting precision and bias statements in test method standards used in the nuclear industry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1992-01-01

    1.1 This guide covers terminology useful for the preparation and interpretation of precision and bias statements. 1.2 In formulating precision and bias statements, it is important to understand the statistical concepts involved and to identify the major sources of variation that affect results. Appendix X1 provides a brief summary of these concepts. 1.3 To illustrate the statistical concepts and to demonstrate some sources of variation, a hypothetical data set has been analyzed in Appendix X2. Reference to this example is made throughout this guide. 1.4 It is difficult and at times impossible to ship nuclear materials for interlaboratory testing. Thus, precision statements for test methods relating to nuclear materials will ordinarily reflect only within-laboratory variation.

  16. Protocol for Cohesionless Sample Preparation for Physical Experimentation

    Science.gov (United States)

    2016-05-01

    Standard test method for consolidated drained triaxial compression test for soils . In Annual book of ASTM standards. West Conshohocken, PA: ASTM...derived wherein uncertainties and laboratory scatter associated with soil fabric-behavior variance during sample preparation are mitigated. Samples of...wherein comparable analysis between different laboratory tests’ results can be made by ensuring a comparable soil fabric prior to laboratory testing

  17. Ultrasound-guided versus computed tomography-scan guided biopsy of pleural-based lung lesions.

    Science.gov (United States)

    Khosla, Rahul; McLean, Anna W; Smith, Jessica A

    2016-01-01

    Computed tomography (CT) guided biopsies have long been the standard technique to obtain tissue from the thoracic cavity and is traditionally performed by interventional radiologists. Ultrasound (US) guided biopsy of pleural-based lesions, performed by pulmonologists is gaining popularity and has the advantage of multi-planar imaging, real-time technique, and the absence of radiation exposure to patients. In this study, we aim to determine the diagnostic accuracy, the time to diagnosis after the initial consult placement, and the complications rates between the two different modalities. A retrospective study of electronic medical records was done of patients who underwent CT-guided biopsies and US-guided biopsies for pleural-based lesions between 2005 and 2014 and the data collected were analyzed for comparing the two groups. A total of 158 patients underwent 162 procedures during the study period. 86 patients underwent 89 procedures in the US group, and 72 patients underwent 73 procedures in the CT group. The overall yield in the US group was 82/89 (92.1%) versus 67/73 (91.8%) in the CT group (P = 1.0). Average days to the procedure was 7.2 versus 17.5 (P = 0.00001) in the US and CT group, respectively. Complication rate was higher in CT group 17/73 (23.3%) versus 1/89 (1.1%) in the US group (P guided biopsy is similar to that of CT-guided biopsy, with a lower complication rate and a significantly reduced time to the procedure.

  18. Radical Recentering: Equity in Educational Leadership Standards

    Science.gov (United States)

    Galloway, Mollie K.; Ishimaru, Ann M.

    2015-01-01

    Background: The widely adopted Interstate School Leaders Licensure Consortium standards are designed to guide the preparation and professional development of educational leaders. However, the standards' limited mention of race, class, ethnicity, ability, gender, sexuality, or other marginalized identities suggests that addressing persistent…

  19. Kinetic and morphological differentiation of ettringites in plain and blended Portland cements with metakaolin and the ASTM C 452-68 test. Part II: Morphological differentiation by SEM and XRD analysis

    Directory of Open Access Journals (Sweden)

    Talero, R.

    2009-03-01

    Full Text Available The same cementitious materials (OPCs, SRPCs and matekaolin, MK, the same blended cements and the same ASTM C 452-68 test than in Part I, were used. Other complementary determinations were: chemical analysis of cementing materials, SEM and XRD analysis of ettringites and specific properties of some cement tested and of their pastes.The experimental results have also demonstrated that when 7.0% SO3, equivalent to 15.05% of gypsum, was added to the M pozzolan-containing Portland cement and tested with the ASTM C 452-68 method, it was not found to behave aggressively but rather as “setting regulator ”, because the increase in mechanical strengths over time and setting times in these mixes were, therefore, similar to the pattern observed in any PC. However, when the gypsum content was raised to triple than that amount (21.0% SO3, it behaved aggressively. In both cases, logically, ettringite from both origins were involved in the resulting beneficial or adverse behavior.En esta Parte II se utilizaron los mismos materiales cementíceos (CPO, CPRS, y metakaolín, MK, los mismos cementos de mezcla y el mismo método de ensayo ASTM C 452-68 que en la Parte I. Otras determinaciones complementarias fueron: análisis químico de los materiales cementíceos, análisis por DRX y SEM de ettringitas y propiedades específicas de algunos cementos ensayados y de sus pastas.Los resultados experimentales obtenidos han demostrado también que, el 7.0% de SO3 presente en los 30 cementos de mezcla con MK, ensayados conforme el método ASTM C 452-68, no se comporta como agresivo sino como ”regulador de fraguado”, porque los tiempos de fraguado y el aumento de resistencias mecánicas fueron como los de cualquier CP. De aquí que algunos de esos cementos de mezcla puedan ser considerados “cementos hidráulicos expansivos”, el resto, no. Sin embargo, cuando la cantidad de yeso aportada fue el triple (21,0% SO3, se comportó como agresivo, motivo por el cual

  20. Standard test method for isotopic abundance analysis of uranium hexafluoride and uranyl nitrate solutions by multi-collector, inductively coupled plasma-mass spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2014-01-01

    1.1 This test method covers the isotopic abundance analysis of 234U, 235U, 236U and 238U in samples of hydrolysed uranium hexafluoride (UF6) by inductively coupled plasma source, multicollector, mass spectrometry (ICP-MC-MS). The method applies to material with 235U abundance in the range of 0.2 to 6 % mass. This test method is also described in ASTM STP 1344. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  1. Nevada Compliance Implementation and Evaluation Guide

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Pamala C.

    2012-08-30

    This Guide is designed to assist state and local code jurisdictions in achieving statewide compliance with the 2009 International Energy Conservation Code (IECC) for residential buildings and ANSI/ASHRAE/IESNA Standard 90.1-2007 for commercial buildings.

  2. Utah Compliance Implementation and Evaluation Guide

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Pamala C.

    2012-08-30

    This Guide is designed to assist state and local code jurisdictions in achieving statewide compliance with the 2009 International Energy Conservation Code (IECC) for residential buildings and ANSI/ASHRAE/IESNA Standard 90.1-2007 for commercial buildings.

  3. Iowa Compliance Implementation and Evaluation Guide

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Pamala C.

    2012-09-04

    This Guide is designed to assist state and local code jurisdictions in achieving statewide compliance with the 2009 International Energy Conservation Code (IECC) for residential buildings and ANSI/ASHRAE/IESNA Standard 90.1-2007 for commercial buildings.

  4. Kinetic and morphological differentiation of Ettringites in plain and blended Portland cements using Metakaolin and the ASTM C 452-68 test. Part I: kinetic differentiation

    Directory of Open Access Journals (Sweden)

    Talero, R.

    2008-12-01

    Full Text Available In this first part of the study, the results obtained in prior research with XRD and SEM, as well as the Le Chatelier-Ansttet test were confirmed with the ASTM C 452-68 test. To this end, 20%, 30% and 40% metakaolin (MK was added to ten Portland cements, six OPCs and four SRPCs. Both the ten plain PCs and the 30 metakaolin (MK blends were tested for two years under ASTM C 452-68 specifications, determining not only the percentage increase in length, ΔL(%, of the specimens, but also the sulphate content in the curing water. Other parameters studied included: chemical analysis of the cementitious materials used and specific properties of some of the cements tested.The experimental results, ΔL(% versus time, re-confirmed that the formation rate of ettringite from the reactive alumina, Al2O3r-, present in the pozzolan must be substantially higher than the formation rate of ettringite from the C3A present in the PC. This was verified by the variation of the sulphate content in the specimen curing water throughout the test. In light of those findings, in this article these two types of ettringite are denominated rapid forming ettringite or ett-rf, and slow forming ettringite or ett-lf.En esta Parte I de la investigación, se han logrado verificar mediante el ensayo ASTM C 452-68, los resultados obtenidos en anteriores investigaciones realizadas con DRX y SEM y el ensayo Le Chatelier-Ansttet. Para ello, a 10 cementos Portland –6 CPO y 4 CPRS– se les añadió 20%, 30% y 40% de metakaolín (MK. Tanto los 10 CP como los 30 de sus mezclas con metakaolín (MK, se ensayaron durante 2 años, mediante dicho método ASTM C 452-68, y a sus probetas no sólo se les determinó su incremento porcentual de longitud, ΔL(%, sino además, el contenido de sulfatos de sus aguas de conservación. Otras determinaciones complementarias fueron: análisis químico de los materiales cementiceos utilizados y propiedades específicas de algunos cementos ensayados

  5. 76 FR 65544 - Standard Format and Content of License Applications for Mixed Oxide Fuel Fabrication Facilities

    Science.gov (United States)

    2011-10-21

    ... NUCLEAR REGULATORY COMMISSION [NRC-2009-0323] Standard Format and Content of License Applications... revision to regulatory guide (RG) 3.39, ``Standard Format and Content of License Applications for Mixed Oxide Fuel Fabrication Facilities.'' This guide endorses the standard format and content for license...

  6. Effects of heat treatment to the sound velocity and microstructural changes of ASTM A516 steels

    International Nuclear Information System (INIS)

    Norasiah Abdul Kasim; Azali Muhammad; Amry Amin Abas; Zaiton Selamat

    2010-01-01

    Full-text: The used of ultrasonic testing as a thickness measurement for structural components (pipeline and pressure vessel) is among the popular inspection tool widely use in the industrial power plant such as at petrochemical and nuclear power plant. Currently, there are cases where the thickness grows and the result will affect the reliability of the test. There are many factors that can affect the reliability of measurement. One of it is the material under test itself. In the Malaysian Nuclear Agency, initial efforts are underway to study the understanding on the effects of heat treatment to the sound velocity and microstructure changes of ASTM A516 steel. Few samples of thin square shaped prepared were heat treated under the following conditions: austenitization at 9800 degree Celsius - 2 hours, quenching; tempering at various temperature 4000, 5000, 6000 and 7000 degree Celsius. The results show that the microstructure changes and samples exhibit different sound velocity at different heat treatment. (author)

  7. Defense Standardization Program Journal, July/December 2007

    Science.gov (United States)

    2007-12-01

    IeqLuirelleCnlts. About the Authors Robert Stenner , a toxicologist at Pacific Northwest National Laboratory (PNNL), has more than 30 years ot experience...in emergency response, environmental health risk analysis, and human health impact analysis of xenobiotic agents. Dr. Stenner also chairs ASTM

  8. IAEA codes and guides for safety of nuclear power plants

    International Nuclear Information System (INIS)

    Raisic, N.

    1980-01-01

    The objectives and scope of the Agency's programme of nuclear safety standards are described and the role of these documents in regulation of nuclear power im Member States is discussed. For each of the five areas of safety standards development, i.e. siting, design, operation, quality assurance and governmental organization, a set of principles underlying requirements and recommendations contained in the Code of Practice and Safety Guides will be presented. Safety Guides in each of the five areas will be reviewed in respect of the scope and content. A consideration will be given to the future development of the safety standards and to the revision and updating of the published documents. (orig./RW)

  9. Radiation: a guide for the layman

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    A brief non-technical guide to ionizing and non-ionizing radiations including sources of these radiations, particularly at work, and their biological effects; radiological protection measures, standards and regulations; the nuclear power industry and safety organization in Britain. (author)

  10. Measure Guideline: Guide to Attic Air Sealing

    Energy Technology Data Exchange (ETDEWEB)

    Lstiburek, J.

    2014-09-01

    The Guide to Attic Air Sealing was completed in 2010 and although not in the standard Measure Guideline format, is intended to be a Measure Guideline on Attic Air Sealing. The guide was reviewed during two industry stakeholders meetings held on December 18th, 2009 and January 15th, 2010, and modified based on the comments received. Please do not make comments on the Building America format of this document. The purpose of the Guide to Attic Air Sealing is to provide information and recommendations for the preparation work necessary prior to adding attic insulation. Even though the purpose of this guide is to save energy - health, safety and durability should not be compromised by energy efficiency. Accordingly, combustion safety and ventilation for indoor air quality are addressed first. Durability and attic ventilation then follow. Finally, to maximize energy savings, air sealing is completed prior to insulating. The guide is intended for home remodelers, builders, insulation contractors, mechanical contractors, general contractors who have previously done remodeling and homeowners as a guide to the work that needs to be done.

  11. Access Structures in a Standard Translation Dictionary | Louw ...

    African Journals Online (AJOL)

    The access structure is the primary guide structure in the central texts of any standard translation dictionary. The metalexicographical term "guide structures" refers to the set of structures that provides a framework within which the accessibility and availability of information types in the dictionary can be evaluated. The access ...

  12. Decommissioning of Medical, Industrial and Research Facilities. Safety Guide

    International Nuclear Information System (INIS)

    2010-01-01

    Radioactive waste is produced in the generation of nuclear power and the use of radioactive materials in industry, research and medicine. The importance of the safe management of radioactive waste for the protection of human health and the environment has long been recognized, and considerable experience has been gained in this field. The IAEA's Radioactive Waste Safety Standards Programme aimed at establishing a coherent and comprehensive set of principles and requirements for the safe management of waste and formulating the guidelines necessary for their application. This is accomplished within the IAEA Safety Standards Series in an internally consistent set of publications that reflect an international consensus. The publications will provide Member States with a comprehensive series of internationally agreed publications to assist in the derivation of, and to complement, national criteria, standards and practices. The Safety Standards Series consists of three categories of publications: Safety Fundamentals, Safety Requirements and Safety Guides. With respect to the Radioactive Waste Safety Standards Programme, the set of publications is currently undergoing review to ensure a harmonized approach throughout the Safety Standards Series. This Safety Guide addresses the subject of decommissioning of medical, industrial and research facilities where radioactive materials and sources are produced, received, used and stored. It is intended to provide guidance to national authorities and operating organizations, particularly to those in developing countries (as such facilities are predominant in these countries), for the planning and safe management of the decommissioning of such facilities. The Safety Guide has been prepared through a series of Consultants meetings and a Technical Committee meeting

  13. Decommissioning of medical, industrial and research facilities. Safety guide

    International Nuclear Information System (INIS)

    2005-01-01

    Radioactive waste is produced in the generation of nuclear power and the use of radioactive materials in industry, research and medicine. The importance of the safe management of radioactive waste for the protection of human health and the environment has long been recognized, and considerable experience has been gained in this field. The IAEA's Radioactive Waste Safety Standards Programme aimed at establishing a coherent and comprehensive set of principles and requirements for the safe management of waste and formulating the guidelines necessary for their application. This is accomplished within the IAEA Safety Standards Series in an internally consistent set of publications that reflect an international consensus. The publications will provide Member States with a comprehensive series of internationally agreed publications to assist in the derivation of, and to complement, national criteria, standards and practices. The Safety Standards Series consists of three categories of publications: Safety Fundamentals, Safety Requirements and Safety Guides. With respect to the Radioactive Waste Safety Standards Programme, the set of publications is currently undergoing review to ensure a harmonized approach throughout the Safety Standards Series. This Safety Guide addresses the subject of decommissioning of medical, industrial and research facilities where radioactive materials and sources are produced, received, used and stored. It is intended to provide guidance to national authorities and operating organizations, particularly to those in developing countries (as such facilities are predominant in these countries), for the planning and safe management of the decommissioning of such facilities. The Safety Guide has been prepared through a series of Consultants meetings and a Technical Committee meeting

  14. Illinois Occupational Skill Standards: Welding Cluster.

    Science.gov (United States)

    Illinois Occupational Skill Standards and Credentialing Council, Carbondale.

    These Illinois skill standards for the welding cluster are intended to serve as a guide to workforce preparation program providers as they define content for their programs and to employers as they establish the skills and standards necessary for job acquisition. They could also serve as a mechanism for communication among education, business,…

  15. Generic Guide Specification for Geothermal Heat Pump Systems

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, WKT

    2000-04-12

    The attached Geothermal (Ground-Source) Heat Pump (GHP) Guide Specifications have been developed by Oak Ridge National Laboratory (ORNL) with the intent to assist federal agency sites and engineers in the preparation of construction specifications for GHP projects. These specifications have been developed in the industry-standard Construction Specification Institute (CSI) format and cover several of the most popular members of the family of GHP systems. These guide specifications are applicable to projects whether the financing is with conventional appropriations, arranged by GHP specialty ESCOs under the U.S. Department of Energy's Technology-Specific GHP Super ESPCs, arranged by utilities under Utility Energy Service Contracts (UESCs) or arranged by generalist ESCOs under the various regional ESPCs. These specifications can provide several benefits to the end user that will help ensure successful GHP system installations. GHP guide specifications will help to streamline the specification development, review, and approval process because the architecture and engineering (AE) firm will be working from the familiar CSI format instead of developing the specifications from other sources. The guide specifications help to provide uniformity, standardization, and consistency in both the construction specifications and system installations across multiple federal sites. This standardization can provide future benefits to the federal sites in respect to both maintenance and operations. GHP guide specifications can help to ensure that the agency is getting its money's worth from the GHP system by preventing the use of marginal or inferior components and equipment. The agency and its AE do not have to start from scratch when developing specifications and can use the specification as a template and/or a checklist in developing both the design and the contract documents. The guide specifications can save project costs by reducing the engineering effort required

  16. Standard guide for mutual inductance bridge applications for wall thickness determinations in boiler tubing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This guide describes a procedure for obtaining relative wall thickness indications in ferromagnetic and non-ferromagnetic steels using the mutual inductance bridge method. The procedure is intended for use with instruments capable of inducing two substantially identical magnetic fields and noting the change in inductance resulting from differing amounts of steel. It is used to distinguish acceptable wall thickness conditions from those which could place tubular vessels or piping at risk of bursting under high temperature and pressure conditions. 1.2 This guide is intended to satisfy two general needs for users of industrial Mutual Inductance Bridge (MIB) equipment: (1) the need for a tutorial guide addressing the general principles of Mutual Inductance Bridges as they apply to industrial piping; and (2) the need for a consistent set of MIB performance parameter definitions, including how these performance parameters relate to MIB system specifications. Potential users and buyers, as well as experienced M...

  17. Standard guide for evaluating performance characteristics of phased-Array ultrasonic testing instruments and systems

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This guide describes procedures for evaluating some performance characteristics of phased-array ultrasonic examination instruments and systems. 1.2 Evaluation of these characteristics is intended to be used for comparing instruments and systems or, by periodic repetition, for detecting long-term changes in the characteristics of a given instrument or system that may be indicative of impending failure, and which, if beyond certain limits, will require corrective maintenance. Instrument characteristics measured in accordance with this guide are expressed in terms that relate to their potential usefulness for ultrasonic examinations. Other electronic instrument characteristics in phased-array units are similar to non-phased-array units and may be measured as described in E 1065 or E 1324. 1.3 Ultrasonic examination systems using pulsed-wave trains and A-scan presentation (rf or video) may be evaluated. 1.4 This guide establishes no performance limits for examination systems; if such acceptance criteria ar...

  18. Decommissioning of nuclear power plants and research reactors. Safety guide

    International Nuclear Information System (INIS)

    1999-01-01

    Radioactive waste is produced in the generation of nuclear power and the use of radioactive materials in industry, research and medicine. The importance of the safe management of radioactive waste for the protection of human health and the environment has long been recognized, and considerable experience has been gained in this field. The IAEA's Radioactive Waste Safety Standards Programme aimed at establishing a coherent and comprehensive set of principles and requirements for the safe management of waste and formulating the guidelines necessary for their application. This is accomplished within the IAEA Safety Standards Series in an internally consistent set of publications that reflect an international consensus. The publications will provide Member States with a comprehensive series of internationally agreed publications to assist in the derivation of, and to complement, national criteria, standards and practices. The Safety Standards Series consists of three categories of publications: Safety Fundamentals, Safety Requirements and Safety Guides. With respect to the Radioactive Waste Safety Standards Programme, the set of publications is currently undergoing review to ensure a harmonized approach throughout the Safety Standards Series. This Safety Guide addresses the subject of decommissioning of nuclear power plants and research reactors. It is intended to provide guidance to national authorities and operating organizations for the planning and safe management of the decommissioning of such installations. This Safety Guide has been prepared through a series of Consultants and Technical Committee meetings. It supersedes former Safety Series publications Nos 52, 74 and 105

  19. Decommissioning of nuclear power plants and research reactors. Safety guide

    International Nuclear Information System (INIS)

    2004-01-01

    Radioactive waste is produced in the generation of nuclear power and the use of radioactive materials in industry, research and medicine. The importance of the safe management of radioactive waste for the protection of human health and the environment has long been recognized, and considerable experience has been gained in this field. The IAEA's Radioactive Waste Safety Standards Programme aimed at establishing a coherent and comprehensive set of principles and requirements for the safe management of waste and formulating the guidelines necessary for their application. This is accomplished within the IAEA Safety Standards Series in an internally consistent set of publications that reflect an international consensus. The publications will provide Member States with a comprehensive series of internationally agreed publications to assist in the derivation of, and to complement, national criteria, standards and practices. The Safety Standards Series consists of three categories of publications: Safety Fundamentals, Safety Requirements and Safety Guides. With respect to the Radioactive Waste Safety Standards Programme, the set of publications is currently undergoing review to ensure a harmonized approach throughout the Safety Standards Series. This Safety Guide addresses the subject of decommissioning of nuclear power plants and research reactors. It is intended to provide guidance to national authorities and operating organizations for the planning and safe management of the decommissioning of such installations. This Safety Guide has been prepared through a series of Consultants and Technical Committee meetings. It supersedes former Safety Series publications Nos 52, 74 and 105

  20. Decommissioning of nuclear power plants and research reactors. Safety guide

    International Nuclear Information System (INIS)

    2001-01-01

    Radioactive waste is produced in the generation of nuclear power and the use of radioactive materials in industry, research and medicine. The importance of the safe management of radioactive waste for the protection of human health and the environment has long been recognized, and considerable experience has been gained in this field. The IAEA's Radioactive Waste Safety Standards Programme aimed at establishing a coherent and comprehensive set of principles and requirements for the safe management of waste and formulating the guidelines necessary for their application. This is accomplished within the IAEA Safety Standards Series in an internally consistent set of publications that reflect an international consensus. The publications will provide Member States with a comprehensive series of internationally agreed publications to assist in the derivation of, and to complement, national criteria, standards and practices. The Safety Standards Series consists of three categories of publications: Safety Fundamentals, Safety Requirements and Safety Guides. With respect to the Radioactive Waste Safety Standards Programme, the set of publications is currently undergoing review to ensure a harmonized approach throughout the Safety Standards Series. This Safety Guide addresses the subject of decommissioning of nuclear power plants and research reactors. It is intended to provide guidance to national authorities and operating organizations for the planning and safe management of the decommissioning of such installations. This Safety Guide has been prepared through a series of Consultants and Technical Committee meetings. It supersedes former Safety Series publications Nos 52, 74 and 105