WorldWideScience

Sample records for astm standard activities

  1. 47 CFR 90.379 - ASTM E2213-03 DSRC Standard (ASTM-DSRC Standard).

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false ASTM E2213-03 DSRC Standard (ASTM-DSRC Standard... Communications Service (dsrcs) § 90.379 ASTM E2213-03 DSRC Standard (ASTM-DSRC Standard). Roadside Units... incorporated by reference: American Society for Testing and Materials (ASTM) E2213-03, “Standard Specification...

  2. ASTM reference radiologic digital image standards

    International Nuclear Information System (INIS)

    Wysnewski, R.; Wysnewski, D.

    1996-01-01

    ASTM Reference Radiographs have been essential in defining industry's material defect grade levels for many years. ASTM Reference Radiographs are used extensively as even the American Society for Metals Nondestructive Inspection and Quality Control Metals Handbook, Volume 11, eighth edition refers to ASTM Standard Reference Radiographs. The recently published E 1648 Standard Reference Radiographs for Examination of Aluminum Fusion Welds is a prime example of the on-going need for these references. To date, 14 Standard Reference Radiographs have been published to characterize material defects. Standard Reference Radiographs do not adequately address film-less radiologic methods. There are differences in mediums to content with. On a computer CRT defect indications appear differently when compared to indications viewed in a radiograph on a view box. Industry that uses non-film radiologic methods of inspection can be burdened with additional time and money developing internal standard reference radiologic images. These references may be deemed necessary for grading levels of product defects. Because there are no ASTM Standard Reference Radiologic data files for addressing this need in the industry, the authors of this paper suggested implementing a method for their creation under ASTM supervision. ASTM can assure continuity to those users making the transition from analog radiographic images to digital image data by swiftly addressing the requirements for reference digital image standards. The current status and possible future activities regarding a method to create digital data files is presented in this paper summary

  3. 46 CFR 163.003-3 - ASTM standard.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false ASTM standard. 163.003-3 Section 163.003-3 Shipping...: SPECIFICATIONS AND APPROVAL CONSTRUCTION Pilot Ladder § 163.003-3 ASTM standard. The following standard of the American Society for Testing and Materials (ASTM) is incorporated by reference into this subpart: ASTM D...

  4. ASTM standards associated with PWR and BWR power plant licensing, operation and surveillance

    International Nuclear Information System (INIS)

    McElroy, W.N.; McElroy, R.J.; Gold, R.; Lippincott, E.P.; Lowe, A.L. Jr.

    1994-01-01

    This paper considers ASTM Standards that are available, under revision, and are being considered in support of Pressurized Water Reactor (PWR) and Boiling Water Reactor (BWR) Nuclear Power Plant (NPP) licensing, regulation, operation, surveillance and life attainment. The current activities of ASTM Committee E10 and its Subcommittees E10.02 and current activities of ASTM Committee E10 and its Subcommittees E10.02 and E10.05 and their Task Groups (TG) are described. A very important aspect of these efforts is the preparation, revision, and balloting of standards identified in the ASTM E706 Standard on Master Matrix for Light Water Reactor (LWR) Pressure Vessel (PV) Surveillance Standards. The current version (E706-87) of the Master Matrix identifies 21 ASTM LWR physics-dosimetry-metallurgy standards for Reactor Pressure Vessel (RPV) and Support Structure (SS) surveillance programs, whereas, for the next revision 34 standards are identified. The need for national and international coordination of Standards Technology Development, Transfer and Training (STDTT) is considered in this and other Symposium papers that address specific standards related physics-dosimetry-metallurgy issues. 69 refs

  5. The USCG/environment Canada/ASTM standards development program

    International Nuclear Information System (INIS)

    Whittaker, H.

    1992-01-01

    Environment Canada's Emergencies Engineering Division (EED) has been charged, as a result of the Public Review Panel on Tanker Safety and Marine Emergency Response report, with increased R ampersand D in marine oil spills. This activity will, of necessity, include development of standards and guidelines for the testing and/or usage of oil spill cleanup equipment. The United States Coast Guard (USCG) has been charged with implementing the provisions of the Oil Pollution Act of 1990 (OPA-90), as it pertains to marine transportation vessels and facilities. Among the provisions are requirements for vessel and facility owners and operators to develop comprehensive response plans that specifically match response resources to spill removal requirements. Meeting the response plan provisions of OPA-90 requires common standards for testing, selecting and assigning resources to anticipated response needs and objectively evaluating response plans for adequacy. In August of 1991, the USCG OPA-90 office approached ASTM to determine the feasibility of developing standards through that organizations procedures. Meetings were then held between the OPA-90 staff and members of the ASTM Committee F-20 on Hazardous Substances and Oil Spill Response. An agreement was reached to commence standards development in the areas of: Barriers, Skimmers, Treating Agents, Pumps, Beach Clean-up, Sorbents, Bioremediation, In-situ Burning, Temporary Storage Devices, Communications, Remote Sensing. It was recognized that ASTM and other organizational standards existed in several of these areas, but there were those where none were known to exist. Standards development was, therefore, expected to be a complicated and time-consuming process. Both the USCG OPA-90 and EC/EED offices required standards to be developed quickly, without subverting the ASTM process. Mechanical containment and recovery was considered to be the primary area of concern for both groups

  6. 47 CFR 95.1509 - ASTM E2213-03 DSRC Standard.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false ASTM E2213-03 DSRC Standard. 95.1509 Section 95... ASTM E2213-03 DSRC Standard. On-Board Units operating in the 5850-5925 MHz band shall comply with the... Materials (ASTM) E2213-03, Standard Specification for Telecommunications and Information Exchange Between...

  7. Annual Book of ASTM Standards, Part 23: Water; Atmospheric Analysis.

    Science.gov (United States)

    American Society for Testing and Materials, Philadelphia, PA.

    Standards for water and atmospheric analysis are compiled in this segment, Part 23, of the American Society for Testing and Materials (ASTM) annual book of standards. It contains all current formally approved ASTM standard and tentative test methods, definitions, recommended practices, proposed methods, classifications, and specifications. One…

  8. ASTM International Workshop on Standards & Measurements for Tissue Engineering Scaffolds

    Science.gov (United States)

    Simon, Carl G.; Yaszemski, Michael J.; Ratcliffe, Anthony; Tomlins, Paul; Luginbuehl, Reto; Tesk, John A.

    2016-01-01

    The “Workshop on Standards & Measurements for Tissue Engineering Scaffolds” was held on May 21, 2013 in Indianapolis, IN and was sponsored by the ASTM International (ASTM). The purpose of the workshop was to identify the highest priority items for future standards work for scaffolds used in the development and manufacture of tissue engineered medical products (TEMPs). Eighteen speakers and 78 attendees met to assess current scaffold standards and to prioritize needs for future standards. A key finding was that the ASTM TEMPs subcommittees (F04.41-46) have many active “guide” documents for educational purposes, but that few standard “test methods” or “practices” have been published. Overwhelmingly, the most clearly identified need was standards for measuring the structure of scaffolds, followed by standards for biological characterization, including in vitro testing, animal models and cell-material interactions. The third most pressing need was to develop standards for assessing the mechanical properties of scaffolds. Additional needs included standards for assessing scaffold degradation, clinical outcomes with scaffolds, effects of sterilization on scaffolds, scaffold composition and drug release from scaffolds. Discussions also highlighted the need for additional scaffold reference materials and the need to use them for measurement traceability. Finally, dialogue emphasized the needs to promote the use of standards in scaffold fabrication, characterization, and commercialization and to assess the use and impact of standards in the TEMPs community. Many scaffold standard needs have been identified and focus should now turn to generating these standards to support the use of scaffolds in TEMPs. PMID:25220952

  9. Standardization work by ASTM and DIN concerning test methods for metallic materials - comparative assessment with regard for practice

    International Nuclear Information System (INIS)

    Gerischer, K.

    1986-01-01

    The article explains the significant role of ASTM and marks out basic elements of the specification system of ASTM standards. Usefulness in practice is taken as the main criterion for the subsequent comparison of ASTM or DIN activities and procedures, and results, for standardization in the field of test methods for metallic materials. The main differences are shown to exist with regard to tropicality of test standards, presentation of useful information and background knowledge, and importance attached to formal questions. ASTM standardization work is shown to be more up-to-date, contain more information, and to be less concerned with formal matters. A closer cooperation between ASTM and DIN is strongly recommended. (orig.) [de

  10. ASTM Standards for Reactor Dosimetry and Pressure Vessel Surveillance

    International Nuclear Information System (INIS)

    GRIFFIN, PATRICK J.

    1999-01-01

    The ASTM standards provide guidance and instruction on how to field and interpret reactor dosimetry. They provide a roadmap towards understanding the current ''state-of-the-art'' in reactor dosimetry, as reflected by the technical community. The consensus basis to the ASTM standards assures the user of an unbiased presentation of technical procedures and interpretations of the measurements. Some insight into the types of standards and the way in which they are organized can assist one in using them in an expeditious manner. Two example are presented to help orient new users to the breadth and interrelationship between the ASTM nuclear metrology standards. One example involves the testing of a new ''widget'' to verify the radiation hardness. The second example involves quantifying the radiation damage at a pressure vessel critical weld location through surveillance dosimetry and calculation

  11. ASTM international workshop on standards and measurements for tissue engineering scaffolds.

    Science.gov (United States)

    Simon, Carl G; Yaszemski, Michael J; Ratcliffe, Anthony; Tomlins, Paul; Luginbuehl, Reto; Tesk, John A

    2015-07-01

    The "Workshop on Standards & Measurements for Tissue Engineering Scaffolds" was held on May 21, 2013 in Indianapolis, IN, and was sponsored by the ASTM International (ASTM). The purpose of the workshop was to identify the highest priority items for future standards work for scaffolds used in the development and manufacture of tissue engineered medical products (TEMPs). Eighteen speakers and 78 attendees met to assess current scaffold standards and to prioritize needs for future standards. A key finding was that the ASTM TEMPs subcommittees (F04.41-46) have many active "guide" documents for educational purposes, but few standard "test methods" or "practices." Overwhelmingly, the most clearly identified need was standards for measuring the structure of scaffolds, followed by standards for biological characterization, including in vitro testing, animal models and cell-material interactions. The third most pressing need was to develop standards for assessing the mechanical properties of scaffolds. Additional needs included standards for assessing scaffold degradation, clinical outcomes with scaffolds, effects of sterilization on scaffolds, scaffold composition, and drug release from scaffolds. Discussions highlighted the need for additional scaffold reference materials and the need to use them for measurement traceability. Workshop participants emphasized the need to promote the use of standards in scaffold fabrication, characterization, and commercialization. Finally, participants noted that standards would be more broadly accepted if their impact in the TEMPs community could be quantified. Many scaffold standard needs have been identified and focus is turning to generating these standards to support the use of scaffolds in TEMPs. © 2014 Wiley Periodicals, Inc.

  12. Method for Estimating Evaporative Potential (IM/CLO) from ASTM Standard Single Wind Velocity Measures

    Science.gov (United States)

    2016-08-10

    IM/CLO) FROM ASTM STANDARD SINGLE WIND VELOCITY MEASURES DISCLAIMER The opinions or assertions contained herein are the private views of the...USARIEM TECHNICAL REPORT T16-14 METHOD FOR ESTIMATING EVAPORATIVE POTENTIAL (IM/CLO) FROM ASTM STANDARD SINGLE WIND VELOCITY... ASTM STANDARD SINGLE WIND VELOCITY MEASURES Adam W. Potter Biophysics and Biomedical Modeling Division U.S. Army Research Institute of Environmental

  13. The role of the American Society for Testing and Materials (ASTM) in providing standards to support reliability technology for nuclear power plants

    International Nuclear Information System (INIS)

    Steele, L.E.

    1978-01-01

    ASTM is an international society for managing the development of standards on characteristics and performance of materials, products, systems and services and the promotion of related knowledge. This paper provides on overview of ASTM, emphasizing its contribution to nuclear systems reliability. In so doing, the author, from his perspective as chairman of ASTM committee E 10 on ''Nuclear Applications and the Measurement of Radiation Effects and the Committee on Standards'', illustrates ASTM contributions to the understanding and control of radiation embrittlement of light-water reactor pressure vessels. Four major related taks are summarized and pertinent standards identified. These include: (1) surveillance practice (5 standards), (2) neutron dosimetry (8 standards), (3) specification for steels for nuclear service (7 standards) and (4) basic guidelines for thermal annealing to correct radiation embrittlement (1 standard). This illustration, a specific accomplishment using ASTM standards, is cited within the context of the broader nuclear-related activities of ASTM. (author)

  14. Developing the (ASTM) voluntary consensus standards required to help implement the National Energy Plan

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    The recommended guide is the first American Society for Testing and Materials (ASTM) matrix in a family of such documents that combined, will help manage the development of the ASTM standards considered necessary to implement the current National Plan for Energy Research, Development, and Demonstration. It is expected that the guide will provide a framework for standards development to complement the nation's research and development in support of critical energy needs. The recommended guide identifies the energy-critical areas that are to be developed, the master ASTM recommended guide for developing the standards required to help the National Plan, the section in which each energy-critical area is covered, and the suggested ASTM lead committee responsible for each area (fossil, solar, geothermal, conservation, fusion, and fission reactor development). A comprehensive matrix to identify the areas of need for which ASTM standards will be required to help implement the National Energy Plan is also presented

  15. ASTM standards for fire debris analysis: a review.

    Science.gov (United States)

    Stauffer, Eric; Lentini, John J

    2003-03-12

    The American Society for Testing and Materials (ASTM) recently updated its standards E 1387 and E 1618 for the analysis of fire debris. The changes in the classification of ignitable liquids are presented in this review. Furthermore, a new standard on extraction of fire debris with solid phase microextraction (SPME) was released. Advantages and drawbacks of this technique are presented and discussed. Also, the standard on cleanup by acid stripping has not been reapproved. Fire debris analysts that use the standards should be aware of these changes.

  16. 77 FR 10358 - Acceptance of ASTM F963-11 as a Mandatory Consumer Product Safety Standard

    Science.gov (United States)

    2012-02-22

    ... CONSUMER PRODUCT SAFETY COMMISSION 16 CFR Chapter II Acceptance of ASTM F963-11 as a Mandatory... have accepted the revised ASTM F963-11 standard titled, Standard Consumer Safety Specifications for Toy Safety. Pursuant to section 106 of the Consumer Product Safety Improvement Act of 2008, ASTM F963-11 will...

  17. 76 FR 12370 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM...

    Science.gov (United States)

    2011-03-07

    ... Production Act of 1993--ASTM International Standards Notice is hereby given that, on February 4, 2011... seq. (``the Act''), ASTM International Standards (``ASTM'') has filed written notifications.... Specifically, ASTM has provided an updated list of current, ongoing ASTM standards activities originating...

  18. 76 FR 34252 - Notice Pursuant to the National Cooperative Research and Production Act of 1993; ASTM...

    Science.gov (United States)

    2011-06-13

    ... Production Act of 1993; ASTM International Standards Notice is hereby given that, on May 11, 2011, pursuant... seq. (``the Act''), ASTM International Standards (``ASTM'') has filed written notifications.... Specifically, ASTM has provided an updated list of current, ongoing ASTM standards activities originating...

  19. Recommendations for fluorescence instrument qualification: the new ASTM Standard Guide.

    Science.gov (United States)

    DeRose, Paul C; Resch-Genger, Ute

    2010-03-01

    Aimed at improving quality assurance and quantitation for modern fluorescence techniques, ASTM International (ASTM) is about to release a Standard Guide for Fluorescence, reviewed here. The guide's main focus is on steady state fluorometry, for which available standards and instrument characterization procedures are discussed along with their purpose, suitability, and general instructions for use. These include the most relevant instrument properties needing qualification, such as linearity and spectral responsivity of the detection system, spectral irradiance reaching the sample, wavelength accuracy, sensitivity or limit of detection for an analyte, and day-to-day performance verification. With proper consideration of method-inherent requirements and limitations, many of these procedures and standards can be adapted to other fluorescence techniques. In addition, procedures for the determination of other relevant fluorometric quantities including fluorescence quantum yields and fluorescence lifetimes are briefly introduced. The guide is a clear and concise reference geared for users of fluorescence instrumentation at all levels of experience and is intended to aid in the ongoing standardization of fluorescence measurements.

  20. 78 FR 1884 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM...

    Science.gov (United States)

    2013-01-09

    ... Production Act of 1993--ASTM International Standards Notice is hereby given that, on December 12, 2012... seq. (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between...

  1. 78 FR 35646 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM...

    Science.gov (United States)

    2013-06-13

    ... Production Act of 1993--ASTM International Standards Notice is hereby given that, on May 10, 2013, pursuant... seq. (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between...

  2. 77 FR 34069 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM...

    Science.gov (United States)

    2012-06-08

    ... Production Act of 1993--ASTM International Standards Notice is hereby given that, on May 11, 2012, pursuant... seq. (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between...

  3. 77 FR 61786 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM...

    Science.gov (United States)

    2012-10-11

    ... Production Act of 1993--ASTM International Standards Notice is hereby given that, on September 10, 2012... seq. (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between May...

  4. 78 FR 64248 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM...

    Science.gov (United States)

    2013-10-28

    ... Production Act of 1993--ASTM International Standards Notice is hereby given that, on September 16, 2013... seq. (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between May...

  5. 78 FR 14836 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM...

    Science.gov (United States)

    2013-03-07

    ... Production Act of 1993--ASTM International Standards Notice is hereby given that, on February 11, 2013... seq. (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between...

  6. 77 FR 14046 - Amended Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM...

    Science.gov (United States)

    2012-03-08

    ... Research and Production Act of 1993--ASTM International Standards Notice is hereby given that, on February..., 15 U.S.C. 4301 et seq. (``the Act''), ASTM International Standards (``ASTM'') has filed written... circumstances. Specifically, ASTM has provided an updated list of current, ongoing ASTM standards activities...

  7. Development of ASTM Standard for SiC-SiC Joint Testing Final Scientific/Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Jacobsen, George [General Atomics, San Diego, CA (United States); Back, Christina [General Atomics, San Diego, CA (United States)

    2015-10-30

    As the nuclear industry moves to advanced ceramic based materials for cladding and core structural materials for a variety of advanced reactors, new standards and test methods are required for material development and licensing purposes. For example, General Atomics (GA) is actively developing silicon carbide (SiC) based composite cladding (SiC-SiC) for its Energy Multiplier Module (EM2), a high efficiency gas cooled fast reactor. Through DOE funding via the advanced reactor concept program, GA developed a new test method for the nominal joint strength of an endplug sealed to advanced ceramic tubes, Fig. 1-1, at ambient and elevated temperatures called the endplug pushout (EPPO) test. This test utilizes widely available universal mechanical testers coupled with clam shell heaters, and specimen size is relatively small, making it a viable post irradiation test method. The culmination of this effort was a draft of an ASTM test standard that will be submitted for approval to the ASTM C28 ceramic committee. Once the standard has been vetted by the ceramics test community, an industry wide standard methodology to test joined tubular ceramic components will be available for the entire nuclear materials community.

  8. CCR+: Metadata Based Extended Personal Health Record Data Model Interoperable with the ASTM CCR Standard.

    Science.gov (United States)

    Park, Yu Rang; Yoon, Young Jo; Jang, Tae Hun; Seo, Hwa Jeong; Kim, Ju Han

    2014-01-01

    Extension of the standard model while retaining compliance with it is a challenging issue because there is currently no method for semantically or syntactically verifying an extended data model. A metadata-based extended model, named CCR+, was designed and implemented to achieve interoperability between standard and extended models. Furthermore, a multilayered validation method was devised to validate the standard and extended models. The American Society for Testing and Materials (ASTM) Community Care Record (CCR) standard was selected to evaluate the CCR+ model; two CCR and one CCR+ XML files were evaluated. In total, 188 metadata were extracted from the ASTM CCR standard; these metadata are semantically interconnected and registered in the metadata registry. An extended-data-model-specific validation file was generated from these metadata. This file can be used in a smartphone application (Health Avatar CCR+) as a part of a multilayered validation. The new CCR+ model was successfully evaluated via a patient-centric exchange scenario involving multiple hospitals, with the results supporting both syntactic and semantic interoperability between the standard CCR and extended, CCR+, model. A feasible method for delivering an extended model that complies with the standard model is presented herein. There is a great need to extend static standard models such as the ASTM CCR in various domains: the methods presented here represent an important reference for achieving interoperability between standard and extended models.

  9. Analysis and evaluation of the Electronic Health Record standard in China: a comparison with the American national standard ASTM E 1384.

    Science.gov (United States)

    Xu, Wei; Guan, Zhiyu; Cao, Hongxin; Zhang, Haiyan; Lu, Min; Li, Tiejun

    2011-08-01

    To analyze and evaluate the newly issued Electronic Health Record (EHR) Architecture and Data Standard of China (Chinese EHR Standard) and identify areas of improvement for future revisions. We compared the Chinese EHR Standard with the standard of the American Society for Testing and Materials Standard Practice for Content and Structure of Electronic Health Records in the United States (ASTM E 1384 Standard). The comparison comprised two steps: (1) comparing the conformance of the two standards to the international standard: Health Informatics-Requirements for an Electronic Health Record Architecture (ISO/TS 18308), and showing how the architectures of the two standards satisfy or deviate from the ISO requirements and (2) comparing the detailed data structures between the two standards. Of the 124 requirement items in ISO/TS 18308, the Chinese EHR Standard and the ASTM E 1384 Standard conformed to 77 (62.1%) and 111 (89.5%), respectively. The Chinese EHR Standard conformed to 34 of 50 Structure requirements (68.0%), 22 of 24 Process requirements (91.7%), and 21 of 50 Other requirements (42.0%). The ASTM E 1384 Standard conformed to 49 of 50 Structure requirements (98.0%), 23 of 24 Process requirements (95.8%), and 39 of 40 Other requirements (78.0%). Further development of the Chinese EHR Standard should focus on supporting privacy and security mechanism, diverse data types, more generic and extensible lower level data structures, and relational attributes for data elements. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  10. 77 FR 1085 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM International

    Science.gov (United States)

    2012-01-09

    ... Production Act of 1993--ASTM International Notice is hereby given that, on December 5, 2011, pursuant to.... (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with the..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between...

  11. Deriving allowable properties of lumber : a practical guide for interpretation of ASTM standards

    Science.gov (United States)

    Alan Bendtsen; William L. Galligan

    1978-01-01

    The ASTM standards for establishing clear wood mechanical properties and for deriving structural grades and related allowable properties for visually graded lumber can be confusing and difficult for the uninitiated to interpret. This report provides a practical guide to using these standards for individuals not familiar with their application. Sample stress...

  12. 75 FR 11196 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM International

    Science.gov (United States)

    2010-03-10

    ... Production Act of 1993--ASTM International Notice is hereby given that, on February 16, 2010, pursuant to.... (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with the..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between May...

  13. 75 FR 65657 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM International

    Science.gov (United States)

    2010-10-26

    ... Production Act of 1993--ASTM International Notice is hereby given that, on September 23, 2010, pursuant to.... (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with the..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between May...

  14. 76 FR 63658 - Notice Pursuant to the National Cooperative Research and Production Act of 1993; ASTM International

    Science.gov (United States)

    2011-10-13

    ... Production Act of 1993; ASTM International Notice is hereby given that, on August 31, 2011, pursuant to.... (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with the..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between May...

  15. Standard guide for high-resolution gamma-ray spectrometry of soil samples. ASTM standard

    International Nuclear Information System (INIS)

    1998-12-01

    This guide is under the jurisdiction of ASTM Committee C-26 on Nuclear Fuel Cycle and is the direct responsibility of Subcommittee C26.05 on Methods of Test. The current edition was approved on Jul. 10, 1998. It was published in December 1998. Copyright American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, West Conshohocken, PA, 19428, USA. This document is available from NTIS under license from ASTM

  16. Interpreting the ASTM 'content standard for digital geospatial metadata'

    Science.gov (United States)

    Nebert, Douglas D.

    1996-01-01

    ASTM and the Federal Geographic Data Committee have developed a content standard for spatial metadata to facilitate documentation, discovery, and retrieval of digital spatial data using vendor-independent terminology. Spatial metadata elements are identifiable quality and content characteristics of a data set that can be tied to a geographic location or area. Several Office of Management and Budget Circulars and initiatives have been issued that specify improved cataloguing of and accessibility to federal data holdings. An Executive Order further requires the use of the metadata content standard to document digital spatial data sets. Collection and reporting of spatial metadata for field investigations performed for the federal government is an anticipated requirement. This paper provides an overview of the draft spatial metadata content standard and a description of how the standard could be applied to investigations collecting spatially-referenced field data.

  17. Mobile Robot and Mobile Manipulator Research Towards ASTM Standards Development.

    Science.gov (United States)

    Bostelman, Roger; Hong, Tsai; Legowik, Steven

    2016-01-01

    Performance standards for industrial mobile robots and mobile manipulators (robot arms onboard mobile robots) have only recently begun development. Low cost and standardized measurement techniques are needed to characterize system performance, compare different systems, and to determine if recalibration is required. This paper discusses work at the National Institute of Standards and Technology (NIST) and within the ASTM Committee F45 on Driverless Automatic Guided Industrial Vehicles. This includes standards for both terminology, F45.91, and for navigation performance test methods, F45.02. The paper defines terms that are being considered. Additionally, the paper describes navigation test methods that are near ballot and docking test methods being designed for consideration within F45.02. This includes the use of low cost artifacts that can provide alternatives to using relatively expensive measurement systems.

  18. ASTM and VAMAS activities in titanium matrix composites test methods development

    Science.gov (United States)

    Johnson, W. S.; Harmon, D. M.; Bartolotta, P. A.; Russ, S. M.

    1994-01-01

    Titanium matrix composites (TMC's) are being considered for a number of aerospace applications ranging from high performance engine components to airframe structures in areas that require high stiffness to weight ratios at temperatures up to 400 C. TMC's exhibit unique mechanical behavior due to fiber-matrix interface failures, matrix cracks bridged by fibers, thermo-viscoplastic behavior of the matrix at elevated temperatures, and the development of significant thermal residual stresses in the composite due to fabrication. Standard testing methodology must be developed to reflect the uniqueness of this type of material systems. The purpose of this paper is to review the current activities in ASTM and Versailles Project on Advanced Materials and Standards (VAMAS) that are directed toward the development of standard test methodology for titanium matrix composites.

  19. Considerations on the ASTM standards 1789-04 and 1422-05 on the forensic examination of ink.

    Science.gov (United States)

    Neumann, Cedric; Margot, Pierre

    2010-09-01

    The ASTM standards on Writing Ink Identification (ASTM 1789-04) and on Writing Ink Comparison (ASTM 1422-05) are the most up-to-date guidelines that have been published on the forensic analysis of ink. The aim of these documents is to cover most aspects of the forensic analysis of ink evidence, from the analysis of ink samples, the comparison of the analytical profile of these samples (with the aim to differentiate them or not), through to the interpretation of the result of the examination of these samples in a forensic context. Significant evolutions in the technology available to forensic scientists, in the quality assurance requirements brought onto them, and in the understanding of frameworks to interpret forensic evidence have been made in recent years. This article reviews the two standards in the light of these evolutions and proposes some practical improvements in terms of the standardization of the analyses, the comparison of ink samples, and the interpretation of ink examination. Some of these suggestions have already been included in a DHS funded project aimed at creating a digital ink library for the United States Secret Service. © 2010 American Academy of Forensic Sciences.

  20. Systematic Approach to Design Tailor Made Fuel Blends That Meets ASTM Standards

    DEFF Research Database (Denmark)

    Intikhab, S.; Kalakul, Sawitree; H., Choudhury

    2015-01-01

    point, vapor pressure, and heat content were determined using analytical instruments according to their respective American Society for Testing and Materials (ASTM) standards. Most of the properties complied well with the industry standards. However, model gasoline had a comparatively low RVP....... On the other hand, model diesel had a significantly higher cloud point and pour point than what is recommended. This deviation will have an impact on the cold flow properties of the fuels. For both fuels, different additives along with their composition have also been determined using the same computational...

  1. Comparisons of ASTM standards cited in the NRC standard review plan, NUREG-0800 and related documents

    International Nuclear Information System (INIS)

    Ankrum, A.R.; Bohlander, K.L.; Gilbert, E.R.; Pawlowski, R.A.; Spiesman, J.B.

    1995-10-01

    This report provides the results of comparisons of the cited and latest versions of ASTM standards cited in the NRC Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants (NUREG 0800) and related documents. The comparisons were performed by Battelle Pacific Northwest Laboratories in support of the NRC's Standard Review Plan Update and Development Program. Significant changes to the standards, from the cited version to the latest version, are described and discussed in a tabular format for each standard. Recommendations for updating each citation in the Standard Review Plan are presented. Technical considerations and suggested changes are included for related regulatory documents (i.e., Regulatory Guides and the Code of Federal Regulations) citing the standard. The results and recommendations presented in this document have not been subjected to NRC staff review

  2. Validation of standard ASTM F2732 and comparison with ISO 11079 with respect to comfort temperature ratings for cold protective clothing.

    Science.gov (United States)

    Gao, Chuansi; Lin, Li-Yen; Halder, Amitava; Kuklane, Kalev; Holmér, Ingvar

    2015-01-01

    American standard ASTM F2732 estimates the lowest environmental temperature for thermal comfort for cold weather protective clothing. International standard ISO 11079 serves the same purpose but expresses cold stress in terms of required clothing insulation for a given cold climate. The objective of this study was to validate and compare the temperature ratings using human subject tests at two levels of metabolic rates (2 and 4 MET corresponding to 116.4 and 232.8 W/m(2)). Nine young and healthy male subjects participated in the cold exposure at 3.4 and -30.6 °C. The results showed that both standards predict similar temperature ratings for an intrinsic clothing insulation of 1.89 clo and for 2 MET activity. The predicted temperature rating for 2 MET activity is consistent with test subjects' thermophysiological responses, perceived thermal sensation and thermal comfort. For 4 MET activity, however, the whole body responses were on the cold side, particularly the responses of the extremities. ASTM F2732 is also limited due to its omission and simplification of three climatic variables (air velocity, radiant temperature and relative humidity) and exposure time in the cold which are of practical importance. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  3. ASTM STANDARD GUIDE FOR EVALUATING DISPOSAL OPTIONS FOR REUSE OF CONCRETE FROM NUCLEAR FACILITY DECOMMISSIONING

    International Nuclear Information System (INIS)

    Phillips, Ann Marie; Meservey, Richard H.

    2003-01-01

    Within the nuclear industry, many contaminated facilities that require decommissioning contain huge volumes of concrete. This concrete is generally disposed of as low-level waste at a high cost. Much of the concrete is lightly contaminated and could be reused as roadbed, fill material, or aggregate for new concrete, thus saving millions of dollars. However, because of the possibility of volumetric contamination and the lack of a method to evaluate the risks and costs of reusing concrete, reuse is rarely considered. To address this problem, Argonne National Laboratory-East (ANL-E) and the Idaho National Engineering and Environmental Laboratory teamed to write a ''concrete protocol'' to help evaluate the ramifications of reusing concrete within the U.S. Department of Energy (DOE). This document, titled the Protocol for Development of Authorized Release Limits for Concrete at U.S. Department of Energy Site (1) is based on ANL-E's previously developed scrap metal recycle protocols; on the 10-step method outlined in DOE's draft handbook, Controlling Release for Reuse or Recycle of Property Containing Residual Radioactive Material (2); and on DOE Order 4500.5, Radiation Protection of the Public and the Environment (3). The DOE concrete protocol was the basis for the ASTM Standard Guide for Evaluating Disposal Options for Concrete from Nuclear Facility Decommissioning, which was written to make the information available to a wider audience outside DOE. The resulting ASTM Standard Guide is a more concise version that can be used by the nuclear industry worldwide to evaluate the risks and costs of reusing concrete from nuclear facility decommissioning. The bulk of the ASTM Standard Guide focuses on evaluating the dose and cost for each disposal option. The user calculates these from the detailed formulas and tabulated data provided, then compares the dose and cost for each disposal option to select the best option that meets regulatory requirements. With this information

  4. Fretting-corrosion at the modular tapers interface: Inspection of standard ASTM F1875-98.

    Science.gov (United States)

    Bingley, Rachel; Martin, Alan; Manfredi, Olivia; Nejadhamzeeigilani, Mahdiyar; Oladokun, Abimbola; Beadling, Andrew Robert; Siddiqui, Sohail; Anderson, James; Thompson, Jonathan; Neville, Anne; Bryant, Michael

    2018-05-01

    Interest in the degradation mechanisms at the modular tapers interfaces has been renewed due to increased reported cases of adverse reactions to metal debris and the appearance of wear and corrosion at the modular tapers interfaces at revision. Over the past two decades, a lot of research has been expended to understand the degradation mechanisms, with two primary implant loading procedures and orientations used consistently across the literature. ASTM F1875-98 is often used as a guide to understand and benchmark the tribocorrosion processes occurring within the modular tapers interface. This article presents a comparison of the two methods outlined in ASTM F1875-98 as well as a critique of the standard considering the current paradigm in pre-clinical assessment of modular tapers.

  5. Impact of ASTM Standard E722 update on radiation damage metrics

    Energy Technology Data Exchange (ETDEWEB)

    DePriest, Kendall Russell [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-06-01

    The impact of recent changes to the ASTM Standard E722 is investigated. The methodological changes in the production of the displacement kerma factors for silicon has significant impact for some energy regions of the 1-MeV(Si) equivalent fluence response function. When evaluating the integral over all neutrons energies in various spectra important to the SNL electronics testing community, the change in the response results in an increase in the total 1-MeV(Si) equivalent fluence of 2 7%. Response functions have been produced and are available for users of both the NuGET and MCNP codes.

  6. Relation between the national handbook of recommended methods for water data acquisition and ASTM standards

    Science.gov (United States)

    Glysson, G. Douglas; Skinner, John V.

    1991-01-01

    In the late 1950's, intense demands for water and growing concerns about declines in the quality of water generated the need for more water-resources data. About thirty Federal agencies, hundreds of State, county and local agencies, and many private organizations had been collecting water data. However, because of differences in procedures and equipment, many of the data bases were incompatible. In 1964, as a step toward establishing more uniformity, the Bureau of the Budget (now the Office of Management and Budget, OMB) issued 'Circular A-67' which presented guidelines for collecting water data and also served as a catalyst for creating the Office of Water Data Coordination (OWDC) within the U.S. Geological Survey. This paper discusses past, present, and future aspects of the relation between methods in the National Handbook and standards published by ASTM (American Society for Testing and Materials) Committee D-19 on Water's Subcommittee D-19.07 on Sediment, Geomorphology, and Open Channel Flow. The discussion also covers historical aspects of standards - development work jointly conducted by OWDC and ASTM.

  7. HACCP: Integrating Science and Management through ASTM Standards

    Science.gov (United States)

    From a technical perspective, hazard analysis-critical control point (HACCP) evaluation may be considered a risk management tool suited to a wide range of applications. As one outcome of a symposium convened by American Society for Testing and Materials (ASTM) in August, 2005, th...

  8. ASTM Committee C28: International Standards for Properties and Performance of Advanced Ceramics-Three Decades of High-Quality, Technically-Rigorous Normalization

    Science.gov (United States)

    Jenkins, Michael G.; Salem, Jonathan A.

    2016-01-01

    Physical and mechanical properties and performance of advanced ceramics and glasses are difficult to measure correctly without the proper techniques. For over three decades, ASTM Committee C28 on Advanced Ceramics, has developed high-quality, technically-rigorous, full-consensus standards (e.g., test methods, practices, guides, terminology) to measure properties and performance of monolithic and composite ceramics that may be applied to glasses in some cases. These standards contain testing particulars for many mechanical, physical, thermal, properties and performance of these materials. As a result these standards are used to generate accurate, reliable, repeatable and complete data. Within Committee C28, users, producers, researchers, designers, academicians, etc. have written, continually updated, and validated through round-robin test programs, 50 standards since the Committee's founding in 1986. This paper provides a detailed retrospective of the 30 years of ASTM Committee C28 including a graphical pictogram listing of C28 standards along with examples of the tangible benefits of standards for advanced ceramics to demonstrate their practical applications.

  9. ASTM Committee C28: International Standards for Properties and Performance of Advanced Ceramics, Three Decades of High-quality, Technically-rigorous Normalization

    Science.gov (United States)

    Jenkins, Michael G.; Salem, Jonathan A.

    2016-01-01

    Physical and mechanical properties and performance of advanced ceramics and glasses are difficult to measure correctly without the proper techniques. For over three decades, ASTM Committee C28 on Advanced Ceramics, has developed high quality, rigorous, full-consensus standards (e.g., test methods, practices, guides, terminology) to measure properties and performance of monolithic and composite ceramics that may be applied to glasses in some cases. These standards testing particulars for many mechanical, physical, thermal, properties and performance of these materials. As a result these standards provide accurate, reliable, repeatable and complete data. Within Committee C28 users, producers, researchers, designers, academicians, etc. have written, continually updated, and validated through round-robin test programs, nearly 50 standards since the Committees founding in 1986. This paper provides a retrospective review of the 30 years of ASTM Committee C28 including a graphical pictogram listing of C28 standards along with examples of the tangible benefits of advanced ceramics standards to demonstrate their practical applications.

  10. Current and future neutron radiography standards

    International Nuclear Information System (INIS)

    Brenizer, J.S.

    1999-01-01

    Only two organizations are actively producing standards which are used in neutron radiology (NR): the American Society of Testing and Materials (ASTM) and the International Organization for Standardization (ISO). Six ASTM standards exist that address the neutron radiography method. Two of the ASTM standards have been extensively used world-wide. ISO has a working group which is developing three standards that also address the neutron radiography method. Two of these are currently making their way through the ISO approval system. No ASTM or ISO standards exist for the neutron radioscopic method. Future ASTM standards will address the neutron radioscopic method and neutron radiologic system characterization. It is expected that similar efforts will be undertaken in ISO. Given the relatively small community providing neutron radiologic services, international cooperation and the need for ISO standards will most likely continue to grow.(author)

  11. 78 FR 57818 - Commission Participation and Commission Employee Involvement in Voluntary Standards Activities

    Science.gov (United States)

    2013-09-20

    ... docket number for this rulemaking. All comments received may be posted without change, including any... found in in such locations as homes, schools, and recreational areas. Voluntary standards activity is an... handled primarily by three standards development/coordinating organizations: ASTM International...

  12. Standard specification for tantalum and tantalum alloy plate, sheet, and strip. ASTM standard

    International Nuclear Information System (INIS)

    1998-09-01

    This specification is under the jurisdiction of ASTM Committee B-10 on Reactive and Refractory Metals and Alloys and is the direct responsibility of Subcommittee B10.03 on Niobium and Tantalum. Current edition approved May 10, 1998 and published September 1998. Originally published as B 708-82. Last previous edition was B 708-92

  13. ASTM Validates Air Pollution Test Methods

    Science.gov (United States)

    Chemical and Engineering News, 1973

    1973-01-01

    The American Society for Testing and Materials (ASTM) has validated six basic methods for measuring pollutants in ambient air as the first part of its Project Threshold. Aim of the project is to establish nationwide consistency in measuring pollutants; determining precision, accuracy and reproducibility of 35 standard measuring methods. (BL)

  14. National standards for the nuclear industry

    International Nuclear Information System (INIS)

    Laing, W.R.; Corbin, L.T.

    1981-01-01

    Standards needs for the nuclear industry are being met by a number of voluntary organizations, such as ANS, ASTM, AWS, ASME, and IEEE. The American National Standards Institute (ANSI) coordinates these activities and approves completed standards as American National Standards. ASTM has two all-nuclear committees, E-10 and C-26. A C-26 subcommittee, Test Methods, has been active in writing analytical chemistry standards for twelve years. Thirteen have been approved as ANSI standards and others are ready for ballot. Work is continuing in all areas of the nuclear fuel cycle

  15. Status on the selection and development of an embrittlement trend curve to use in ASTM standard guide E900

    International Nuclear Information System (INIS)

    Kirk, M.; Brian Hall, J.; Server, W.; Lucon, E.; Erickson, M.; Stoller, R.

    2015-01-01

    ASTM E900-07, Standard Guide for Predicting Radiation-Induced Transition Temperature Shift in Reactor Vessel Materials, includes an embrittlement trend curve. The trend curve can be used to predict the effect of neutron irradiation on the embrittlement of ferritic pressure vessel steels, as quantified by the shift in the Charpy V-Notch transition curve at 41 Joules of absorbed energy (ΔT 41J ). The current E900 trend curve was first adopted in the 2002 revision. In 2011 ASTM Subcommittee E10.02 undertook an extensive effort to evaluate the adequacy of the E900 trend curve for continued use. This paper summarizes the current status of this effort, which has produced a trend curve calibrated using a database of over 1800 ΔT 41J values from the light water reactor surveillance programs in thirteen countries. (authors)

  16. An evaluation of efforts by nuclear power plants to use ASTM D3803-89

    International Nuclear Information System (INIS)

    Freeman, W.P.

    1995-01-01

    The number of nuclear power plants are now using ASTM D3803-89, open-quotes Standard Test Method for Nuclear-Grade Activated Carbonclose quotes for routine surveillance testing of adsorbents. In order to judge the impact of this change, we have gathered radioiodine removal test results from our data base on a system-by-system basis (i.e. control room, technical support center, and spent fuel pool) and compared test results obtained for the same kind of systems using the new and older test methods. Included in this comparison are systems with and without humidity control. Results are discussed from the standpoint of what to expect if a change to testing using ASTM D3803-89 is contemplated, especially regarding test results in light existing acceptance criteria. Additionally, the results are discussed from the standpoint of the sensitivity of the ASTM test method to detect when the performance of the carbon in air cleaning systems has been compromised (compared to the older methods). Finally, we offer some suggestions for how other plants might upgrade their carbon testing to incorporate testing to ASTM D3803-89

  17. An evaluation of efforts by nuclear power plants to use ASTM D3803-89

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, W.P.

    1995-02-01

    The number of nuclear power plants are now using ASTM D3803-89, {open_quotes}Standard Test Method for Nuclear-Grade Activated Carbon{close_quotes} for routine surveillance testing of adsorbents. In order to judge the impact of this change, we have gathered radioiodine removal test results from our data base on a system-by-system basis (i.e. control room, technical support center, and spent fuel pool) and compared test results obtained for the same kind of systems using the new and older test methods. Included in this comparison are systems with and without humidity control. Results are discussed from the standpoint of what to expect if a change to testing using ASTM D3803-89 is contemplated, especially regarding test results in light existing acceptance criteria. Additionally, the results are discussed from the standpoint of the sensitivity of the ASTM test method to detect when the performance of the carbon in air cleaning systems has been compromised (compared to the older methods). Finally, we offer some suggestions for how other plants might upgrade their carbon testing to incorporate testing to ASTM D3803-89.

  18. Spectrophotometric determination of the ASTM color of diesel oil

    Energy Technology Data Exchange (ETDEWEB)

    Douglas Willian Emanuel Alves Santana; Marcelle Prates Sepulveda; Paulo Jorge Sanches Barbeira

    2007-03-15

    One of the parameters analyzed to determine the quality of diesel oil is its ASTM color. Changes in color may be indicative of problems in the production process, contamination, degradation or the oxidation of diesel. The methodology recommended for determining the color of automotive diesel oil samples is the colorimetry according to standard ASTM D1500, in which a sample is introduced into a glass cell and the color of the sample is compared with an optical filter color scale. Although it is very simple, the manual method requires good visual acuity from the operator. This procedure becomes somewhat subjective in some cases since different operators can make distinct evaluations of the same sample. In this way, this work proposes the development of a spectrophotometric analysis methodology to eliminate the subjectiveness in the determination of ASTM color of diesel oil samples by using operator-independent parameters and making quality assay more accurate and precise. Short communication. 7 refs., 2 figs., 2 tabs.

  19. Measurement of susceptibility artifacts with histogram-based reference value on magnetic resonance images according to standard ASTM F2119.

    Science.gov (United States)

    Heinrich, Andreas; Teichgräber, Ulf K; Güttler, Felix V

    2015-12-01

    The standard ASTM F2119 describes a test method for measuring the size of a susceptibility artifact based on the example of a passive implant. A pixel in an image is considered to be a part of an image artifact if the intensity is changed by at least 30% in the presence of a test object, compared to a reference image in which the test object is absent (reference value). The aim of this paper is to simplify and accelerate the test method using a histogram-based reference value. Four test objects were scanned parallel and perpendicular to the main magnetic field, and the largest susceptibility artifacts were measured using two methods of reference value determination (reference image-based and histogram-based reference value). The results between both methods were compared using the Mann-Whitney U-test. The difference between both reference values was 42.35 ± 23.66. The difference of artifact size was 0.64 ± 0.69 mm. The artifact sizes of both methods did not show significant differences; the p-value of the Mann-Whitney U-test was between 0.710 and 0.521. A standard-conform method for a rapid, objective, and reproducible evaluation of susceptibility artifacts could be implemented. The result of the histogram-based method does not significantly differ from the ASTM-conform method.

  20. PROPOSED ASTM METHOD FOR THE DETERMINATION OF ASBESTOS IN AIR BY TEM AND INFORMATION ON INTERFERING FIBERS

    Science.gov (United States)

    The draft of the ASTM Test Method for air entitled: "Airborne Asbestos Concentration in Ambient and Indoor Atmospheres as Determined by Transmission Electron Microscopy Direct Transfer (TEM)" (ASTM Z7077Z) is an adaptation of the International Standard, ISO 10312. It is currently...

  1. ASTM and ASME-BPE Standards--Complying with the Needs of the Pharmaceutical Industry.

    Science.gov (United States)

    Huitt, William M

    2011-01-01

    Designing and building a pharmaceutical facility requires the owner, engineer of record, and constructor to be knowledgeable with regard to the industry codes and standards that apply to this effort. Up until 1997 there were no industry standards directed at the needs and requirements of the pharmaceutical industry. Prior to that time it was a patchwork effort at resourcing and adopting nonpharmaceutical-related codes and standards and then modifying them in order to meet the more stringent requirements of the Food and Drug Administration (FDA). In 1997 the American Society of Mechanical Engineers (ASME) published the first Bioprocessing Equipment (BPE) Standard. Through harmonization efforts this relatively new standard has brought together, scrutinized, and refined industry accepted methodologies together with FDA compliance requirements, and has established an American National Standard that provides a comprehensive set of standards that are integral to the pharmaceutical industry. This article describes various American National Standards, including those developed and published by the American Society for Testing and Materials (ASTM), and how they apply to the pharmaceutical industry. It goes on to discuss the harmonization effort that takes place between the various standards developers in an attempt to prevent conflicts and omissions between the many standards. Also included are examples of tables and figures taken from the ASME-BPE Standard. These examples provide the reader with insight to the relevant content of the ASME-BPE Standard. Designing and building a pharmaceutical facility requires the owner, engineer of record, and constructor to be knowledgeable with regard to the industry codes and standards that apply to this effort. Up until 1997 there were no industry standards directed at the needs and requirements of the pharmaceutical industry. Prior to that time it was a patchwork effort at resourcing and adopting nonpharmaceutical-related codes and

  2. Silicon Damage Response Function Derivation and Verification: Assessment of Impact on ASTM Standard E722

    Energy Technology Data Exchange (ETDEWEB)

    Depriest, Kendall [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-06-01

    Unsuccessful attempts by members of the radiation effects community to independently derive the Norgett-Robinson-Torrens (NRT) damage energy factors for silicon in ASTM standard E722-14 led to an investigation of the software coding and data that produced those damage energy factors. The ad hoc collaboration to discover the reason for lack of agreement revealed a coding error and resulted in a report documenting the methodology to produce the response function for the standard. The recommended changes in the NRT damage energy factors for silicon are shown to have significant impact for a narrow energy region of the 1-MeV(Si) equivalent fluence response function. However, when evaluating integral metrics over all neutrons energies in various spectra important to the SNL electronics testing community, the change in the response results in a small decrease in the total 1- MeV(Si) equivalent fluence of ~0.6% compared to the E722-14 response. Response functions based on the newly recommended NRT damage energy factors have been produced and are available for users of both the NuGET and MCNP codes.

  3. ASTM Committee D-7 : Wood : promoting safety and standardization for 100 years

    Science.gov (United States)

    David W. Green; Robert L. Ethington

    2004-01-01

    In October 2004, Committee D-7 on Wood of the American Society for Testing and Materials (ASTM) is celebrating 100 years of contributions to the safe and efficient use of wood as a building material. Born during a period of rapid social, economic, and technological change, the Committee faced controversial issues and the challenge of a changing forest resource. This...

  4. Standard test method for compressive strength of grouts for preplaced-aggregate concrete in the laboratory. ASTM standard

    International Nuclear Information System (INIS)

    1998-10-01

    DoD adopted. This test method is under the jurisdiction of ASTM Committee C-9 on Concrete and Concrete Aggregates and is the direct responsibility of Subcommittee C09.41 on Concrete for Radiation Shielding. Current edition approved Feb. 10, 1986 and published October 1998. Originally published as C 942-81. Last previous edition was C 942-86(1991)

  5. Standard test method for static leaching of monolithic waste forms for disposal of radioactive waste. ASTM standard

    International Nuclear Information System (INIS)

    1998-10-01

    This test method is under the jurisdiction of ASTM Committee C-26 on Nuclear Fuel Cycles and is the direct responsibility of Subcommittee C26.07 on Waste Materials. The current edition was approved July 10, 1998, and published in October 1998. It was originally published as C 1220-92. The last previous edition was C 1220-92

  6. Modification of ASTM Standard E1681 on Environmental Cracking to Include Bolt-Load Specimen Testing

    National Research Council Canada - National Science Library

    Underwood, Jean D. M

    1997-01-01

    Benet Laboratories experience with environmental cracking of cannon components has been combined with the technical expertise of various participants at ASTM technical meetings and symposia to develop...

  7. Empirical ranking of a wide range of WC-Co grades in terms of their abrasion resistance measured by the ASTM standard B 611-85 test

    CSIR Research Space (South Africa)

    O'Quigley, DGF

    1997-01-01

    Full Text Available This paper reports the results of a comprehensive investigation into the abrasion resistance of WC-Co alloys, as measured by the ASTM Standard B 611-85 test. The alloys ranged from 3 to 50 wt% and from 0.6 to 5 mu-m average grain size. Careful...

  8. Evaluation of ozonated water using ASTM E1174 for standardized testing of handwash formulations for healthcare personnel.

    Science.gov (United States)

    Nakamura, K; Saito, K; Kashiwazaki, J; Aoyagi, T; Arai, K; Hara, Y; Kobari, S; Mori, H; Ohashi, K; Takano, Y; Kaku, M; Kanemitsu, K

    2018-02-13

    Removal of bacteria by handwashing with ozonated water was evaluated using the ASTM E1174 standard test method. Thirty healthy volunteers were assigned randomly to three groups: ozonated water, antimicrobial soap and water, and non-antimicrobial soap and water. A 3 log 10  cfu reduction was achieved by washing hands with ozonated water or antimicrobial soap and water. However, ozonated water was not significantly superior to non-antimicrobial soap and water. Ozonated water may remove bacteria from the hands to at least a similar extent as that by non-antimicrobial soap and water in the absence of visible dirt or body fluid contamination. Copyright © 2018 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  9. International cooperative effort to establish ASTM [American Society for Testing and Materials] standards for the measurement of radiation dose for food processing

    International Nuclear Information System (INIS)

    Farrar, H. IV.

    1987-01-01

    A task group has been formed within the American Society for Testing and Materials (ASTM) specifically to develop standards for measuring radiation dose for food processing. The task group, which has 78 members, including 16 from Europe, consists of a broad cross section of food industry, government, regulatory, manufacturing, and university interests. The group is working on seven standards; three specifically for food irradiation applications, and four for using specific dosimeter types for all radiation applications, including food processing. Together, this set of standards will specify acceptable methods of accomplishing the required irradiation treatment of food and other products, and will be available for adoption by regulatory agencies in food irradiation protocols. 1 tab

  10. ASTM lights the way for tissue engineered medical products standards: jump start for combination medical products that restore biological function of human tissues.

    Science.gov (United States)

    Picciolo, G L; Stocum, D L

    2001-01-01

    Everybody hopes for better health and restoration of impaired bodily function, and now that hope is illuminated by the promise of powerful biological tools that make human cells grow and replace human tissue. ASTM Committee F04 on Medical and Surgical Materials and Devices is taking the lead by defining some of those tools as standards that can be used for the development, production, testing, and regulatory approval of medical products.

  11. Applying consensus standards to cask development

    International Nuclear Information System (INIS)

    Leatham, J.; Abbott, D.G.; Warrant, M.M.

    1987-01-01

    The Department of Energy's (DOE's) Office of Civilian Radioactive Waste Management is procuring cask systems for transporting commercial spent nuclear fuel and is encouraging development of innovative cask designs and materials to improve system efficiency. New designs and innovative materials require that consensus standards be established so that cask designers and regulators have criteria for determining acceptability. Recent DOE experience in certifying three spent fuel shipping casks, NUPAC-125B, TN-BRP, and TN-REG, is discussed. Certification of the NUPAC-125B was expedited because it was made of conventional American Society for Testing and Materials (ASTM) materials and complied with the American Society of Mechanical Engineers (ASME) Code and Nuclear Regulatory Commission Regulatory Guides. The TN-BRP and TN-REG cask designs are still being reviewed because baskets included in the casks are made of borated stainless steel, which has no ASTM Specification or ASME Code approval. The process of developing and approving consensus standards is discussed, including the role of ANSI and ANSI N14. Specific procedures for ASTM and ASME are described. A draft specification or standard must be prepared and then approved by the appropriate body. For new material applications to the ASME Code, an existing ASTM Specification is needed. These processes may require several years. The status of activities currently in progress to develop consensus standards for spent fuel casks is discussed, including (1) ASME NUPAC, and (2) ASTM Specifications for ductile cast iron and borated stainless steel

  12. Status of Standardization Projects

    Science.gov (United States)

    1993-12-31

    A5 B 942 943 943 ASM SA 69 D, 8115 056; ASTM D 5118 FABRICATION OF FIBERBOARD SM AS B 941 943 943 A SM SA 69 Di- N 8115 0562 ASTM D 5168 FAB AND...DR&E(AR)759 STANDARDIZATION PROJECTS REPORT - 1ST QTR FY 1994 PREPARING ACTIVITY LISTING PA AAPAA p BPP .A- G/ASA NC AC 21 RC G CSOL- Qý yqFyýFT7RL AL...941 943 943 A SM SA 69 DH N 8115 0562 ASTM D 5168 FAB AND CLOSURE TRIPLE WALL SM AS B 941 943 943 A SM SA 69 DH N 8125 0379 V’L-B-61000 BOTTLES

  13. Light-water reactor pressure vessel surveillance standards

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    The master matrix standard describes a series of standard practices, guides, and methods for the prediction of neutron-induced changes in light-water reactor (LWR) pressure vessel steels throughout a pressure vessel's service life. Some of these are existing American Society for Testing and Materials (ASTM) standards, some are ASTM standards that have been modified, and some are newly proposed ASTM standards. The current (1) scope, (2) areas of application, (3) interrelationships, and (4) status and time table of development, improvement, validation, and calibration for a series of 16 ASTM standards are defined. The standard also includes a discussion of LWR pressure vessel surveillance - justification, requirements, and status of work

  14. Standards in capstone design courses and the engineering curriculum.

    Science.gov (United States)

    Goldberg, Jay

    2012-01-01

    In 1990, I was the group leader of Research and Development for Surgitek, a urological device manufacturer in Racine, Wisconsin, which was the market leader in ureteral stents. I recognized the need for an industry standard for ureteral stents, felt that taking a leadership role in the development of a new standard would be a good professional development activity, and volunteered to serve as the chair of the American Society for Testing and Materials (ASTM, now known as ASTM International) Task Group on Ureteral Stents. After several years, the standard was approved, and I continue to serve as the chair of the ASTM Subcommittee on Urological Materials and Devices. This experience helped me understand the value of industry standards, expanded my professional network and visibility within the medical device industry, and helped develop my leadership skills.

  15. Standard specification for cobalt-chromium-nickel-molybdenum-tungsten alloy (UNS R31233) plate, sheet and strip. ASTM standard

    International Nuclear Information System (INIS)

    1998-09-01

    This specification is under the jurisdiction of ASTM Committee B-2 on Nonferrous Metals and Alloys and is the direct responsibility of Subcommittee B02.07 on Refined Nickel and Cobalt, and Alloys Containing Nickel or Cobalt or Both as Principal Constituents. Current edition approved Apr. 10, 1998 and published September 1998. Originally published as B 818-91. Last previous edition was B 818-93

  16. Overview (this manuscript is an overview of an ASTM ...

    Science.gov (United States)

    The Symposium on Developing Consensus Standards for Measuring Chemical Emissions from Spray Polyurethane Foam (SPF) Insulation was held on April 30th and May 1, 2015. Sponsored by ASTM Committee D22 on Air Quality, the symposium was held in Anaheim, CA, in conjunction with the standards development meetings of the Committee. ASTM D22.05 is developing tools to answer fundamental questions: what is emitted from SPF, how long do the emissions persist, how does ventilation impact concentrations and potential exposures? How can we model these processes to address the multiplicity of products, applications, and environmental conditions that may impact exposure to emissions over the life cycle of the material? These are complex and interrelated questions that have challenged the indoor environments research community for many years. Objectives of Symposium: Standardized methods are needed to assess the potential impacts of SPF insulation products on indoor air quality, establish re-entry times for trade workers or re-occupancy times for building occupants after product installation and to evaluate post-occupancy ventilation. The objective of the symposium was to provide a forum for the exchange of ideas from SPF manufacturers, regulatory agencies, indoor air quality professionals, testing labs, air quality consultants, instrument vendors and other stakeholders. Following the presentations on the current status of measuring emissions from SPF insulation, participants di

  17. An Evaluation of a Proposed Revision of the ASTM D 1990 Grouping Procedure

    Science.gov (United States)

    Steve P Verrill; James W. Evans; David E. Kretschmann; Cherilyn A. Hatfield

    2013-01-01

    Lum, Taylor, and Zidek have proposed a revised procedure for wood species grouping in ASTM standard D 1990. We applaud the authors’ recognition of the importance of considering a strength distribution’s variability as well as its fifth percentile. However, we have concerns about their proposed method of incorporating this information into a standard. We detail these...

  18. Comparison of ASTM D613 and ASTM D6890

    Science.gov (United States)

    2016-04-01

    cetane values outside of the routine range of traditional CN testing by ASTM D613, this is an important advantage in fuel blending and disposition...Number testing. Particular emphasis was placed on evaluating fuels, and blends thereof, having cetane values outside of the normal range of the...interest covers both petroleum-based and synthetic-based, as well as blends thereof in order to improve the confidence in using DCN as a replacement

  19. Comparing the Methodologies in ASTM G198: Is There an Easy Way Out?

    Science.gov (United States)

    Samuel L. Zelinka

    2013-01-01

    ASTM(1) G198, Standard test method for determining the relative corrosion performance of driven fasteners in contact with treated wood, was accepted by consensus and published in 2011. The method has two different exposure conditions for determining fastener corrosion performance in treated wood. The first method places the wood and embedded...

  20. Comparing the Methodologies in ASTM G198 Using Combined Hygrothermal-Corrosion Modeling

    Science.gov (United States)

    Samuel L. Zelinka

    2013-01-01

    ASTM G198, “Standard test method for determining the relative corrosion performance of driven fasteners in contact with treated wood,” was accepted by consensus and published in 2011. The method has two different exposure conditions for determining fastener corrosion performance in treated wood. The first method places the wood and embedded fasteners in a...

  1. 1991 annual book of ASTM standards

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    This book contains nuclear technology standards also features test methods and practices for solar and geotechnical energy. In the nuclear category, the primary emphasis of this volume is on analysis, dosimetry, and radiation effects in materials. Over eighty standards primarily test methods and practices are featured in this category

  2. Results of ASTM round robin testing for mode 1 interlaminar fracture toughness of composite materials

    Science.gov (United States)

    Obrien, T. Kevin; Martin, Roderick H.

    1992-01-01

    The results are summarized of several interlaboratory 'round robin' test programs for measuring the mode 1 interlaminar fracture toughness of advanced fiber reinforced composite materials. Double Cantilever Beam (DCB) tests were conducted by participants in ASTM committee D30 on High Modulus Fibers and their Composites and by representatives of the European Group on Fracture (EGF) and the Japanese Industrial Standards Group (JIS). DCB tests were performed on three AS4 carbon fiber reinforced composite materials: AS4/3501-6 with a brittle epoxy matrix; AS4/BP907 with a tough epoxy matrix; and AS4/PEEK with a tough thermoplastic matrix. Difficulties encountered in manufacturing panels, as well as conducting the tests are discussed. Critical issues that developed during the course of the testing are highlighted. Results of the round robin testing used to determine the precision of the ASTM DCB test standard are summarized.

  3. Standard practice for application of thermoluminescence-dosimetry (TLD) systems for determining absorbed dose in radiation-hardness testing of electronic devices. ASTM standard

    International Nuclear Information System (INIS)

    1998-05-01

    This practice is under the jurisdiction of ASTM Committee E-10 on Nuclear Technology and Applications and is the direct responsibility of Subcommittee E10.07 on Radiation Dosimetry for Radiation Effects on Materials and Devices. Current edition approved Jun. 10, 1997. Published May 1998. Originally published as E 668-78. Last previous edition E 668-93

  4. Standard Master Matrix for Light-Water Reactor Pressure Vessel Surveillance Standards, E706(0)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This master matrix standard describes a series of standard practices, guides, and methods for the prediction of neutron-induced changes in light-water reactor (LWR) pressure vessel (PV) and support structure steels throughout a pressure vessel's service life (Fig. 1). Some of these are existing ASTM standards, some are ASTM standards that have been modified, and some are proposed ASTM standards. General requirements of content and consistency are discussed in Section 6 . More detailed writers' and users' information, justification, and specific requirements for the nine practices, ten guides, and three methods are provided in Sections 3-5. Referenced documents are discussed in Section 2. The summary-type information that is provided in Sections 3 and 4 is essential for establishing proper understanding and communications between the writers and users of this set of matrix standards. It was extracted from the referenced documents, Section 2 and references (1-106) for use by individual writers and users. 1...

  5. Disinfectant wipes are appropriate to control microbial bioburden from surfaces: use of a new ASTM standard test protocol to demonstrate efficacy.

    Science.gov (United States)

    Sattar, S A; Bradley, C; Kibbee, R; Wesgate, R; Wilkinson, M A C; Sharpe, T; Maillard, J-Y

    2015-12-01

    The use of disinfectant pre-soaked wipes (DPW) to decontaminate high-touch environmental surfaces (HTES) by wiping is becoming increasingly widespread in the healthcare environment. However, DPW are rarely tested using conditions simulating their field use, and the label claims of environmental surface disinfectants seldom include wiping action. To evaluate the new E2967-15 standard test specific to wipes, particularly their ability to decontaminate surfaces and to transfer acquired contamination to clean surfaces. ASTM Standard E2967-15 was used by three independent laboratories to test the efficacy of five types of commercially available wipe products. All data generated were pulled together, and reproducibility and repeatability of the standard were measured. All the commercial DPW tested achieved a >4log10 (>99.99%) reduction in colony-forming units (CFU) of Staphylococcus aureus and Acinetobacter baumanii with 10s of wiping, but only one DPW containing 0.5% accelerated H2O2 prevented the transfer of bacteria to another surface. This newly introduced standard method represents a significant advance in assessing DPW for microbial decontamination of HTES, and should greatly assist research and development, and in making more relevant and reliable claims on marketed DPW. Copyright © 2015. Published by Elsevier Ltd.

  6. Use of Bayesian Methods to Analyze and Visualize Content Uniformity Capability Versus United States Pharmacopeia and ASTM Standards.

    Science.gov (United States)

    Hofer, Jeffrey D; Rauk, Adam P

    2017-02-01

    The purpose of this work was to develop a straightforward and robust approach to analyze and summarize the ability of content uniformity data to meet different criteria. A robust Bayesian statistical analysis methodology is presented which provides a concise and easily interpretable visual summary of the content uniformity analysis results. The visualization displays individual batch analysis results and shows whether there is high confidence that different content uniformity criteria could be met a high percentage of the time in the future. The 3 tests assessed are as follows: (a) United States Pharmacopeia Uniformity of Dosage Units , (b) a specific ASTM E2810 Sampling Plan 1 criterion to potentially be used for routine release testing, and (c) another specific ASTM E2810 Sampling Plan 2 criterion to potentially be used for process validation. The approach shown here could readily be used to create similar result summaries for other potential criteria. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  7. Evaluating the Sporicidal Activity of Disinfectants against Clostridium difficile and Bacillus amyloliquefaciens Spores by Using the Improved Methods Based on ASTM E2197-11.

    Science.gov (United States)

    Uwamahoro, Marie Christine; Massicotte, Richard; Hurtubise, Yves; Gagné-Bourque, François; Mafu, Akier Assanta; Yahia, L'Hocine

    2018-01-01

    Spore-forming pathogenic bacteria, such as Clostridium difficile , are associated with nosocomial infection, leading to the increased use of sporicidal disinfectants, which impacts socioeconomic costs. However, C. difficile can be prevented using microorganisms such as Bacillus amyloliquefaciens , a prophylactic agent that has been proven to be effective against it in recent tests or it can be controlled by sporicidal disinfectants. These disinfectants against spores should be evaluated according to a known and recommended standard. Unfortunately, some newly manufactured disinfectants like Bioxy products have not yet been tested. ASTM E2197-11 is a standard test that uses stainless steel disks (1 cm in diameter) as carriers, and the performance of the test formulation is calculated by comparing the number of viable test organisms to that on the control carriers. Surface tests are preferable for evaluating disinfectants with sporicidal effects on hard surfaces. This study applies improved methods, based on the ASTM E2197-11 standard, for evaluating and comparing the sporicidal efficacies of several disinfectants against spores of C. difficile and B. amyloliquefaciens , which are used as the test organisms. With the improved method, all spores were recovered through vortexing and membrane filtration. The results show that chlorine-based products are effective in 5 min and Bioxy products at 5% w/v are effective in 10 min. Although Bioxy products may take longer to prove their effectiveness, their non-harmful effects to hospital surfaces and people have been well established in the literature.

  8. Stress corrosion (Astm G30-90 standard) in 08x18H10T stainless steel of nuclear fuel storage pool in WWER reactors

    International Nuclear Information System (INIS)

    Herrera, V.; Zamora R, L.

    1997-01-01

    At the water storage of the irradiated nuclear fuel has been an important factor in its management. The actual pools have its walls covered with inoxidable steel and heat exchangers to dissipate the residual heat from fuel. It is essential to control the water purity to eliminate those conditions which aid to the corrosion process in fuel and at related components. The steel used in this research was obtained from an austenitic inoxidizable steel standardized with titanium 08x18H10T (Type 321) similar to one of the two steel coatings used to cover walls and the pools floor. the test consisted in the specimen deformation through an U ply according to the Astm G30-90 standard. The exposition of the deformed specimen it was realized in simulated conditions to the chemical regime used in pools. (Author)

  9. Summary: Update to ASTM guide E 1523 to charge control and charge referencing techniques in x-ray photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Baer, D.R.

    2005-01-01

    An updated version of the American Society for Testing and Materials (ASTM) guide E 1523 to the methods to charge control and charge referencing techniques in x-ray photoelectron spectroscopy has been released by ASTM [Annual Book of ASTM Standards Surface Analysis (American Society for Testing and Materials, West Conshohocken, PA, 2004), Vol. 03.06]. The guide is meant to acquaint x-ray photoelectron spectroscopy (XPS) users with the various charge control and charge referencing techniques that are and have been used in the acquisition and interpretation of XPS data from surfaces of insulating specimens. The current guide has been expanded to include new references as well as recommendations for reporting information on charge control and charge referencing. The previous version of the document had been published in 1997 [D. R. Baer and K. D. Bomben, J. Vac. Sci. Technol. A 16, 754 (1998)

  10. Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This document provides guidance in determining absorbed-dose distributions in products, materials or substances irradiated in gamma, X-ray (bremsstrahlung) and electron beam facilities. Note 1—For irradiation of food and the radiation sterilization of health care products, other specific ISO and ISO/ASTM standards containing dose mapping requirements exist. For food irradiation, see ISO/ASTM 51204, Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing and ISO/ASTM 51431, Practice for Dosimetry in Electron and Bremsstrahlung Irradiation Facilities for Food Processing. For the radiation sterilization of health care products, see ISO 11137: 1995, Sterilization of Health Care Products Requirements for Validation and Routine Control Radiation Sterilization. In those areas covered by ISO 11137, that standard takes precedence. ISO/ASTM Practice 51608, ISO/ASTM Practice 51649, and ISO/ASTM Practice 51702 also contain dose mapping requirements. 1.2 Methods of analyzing the dose map data ar...

  11. 24 CFR Appendix A to Part 200 - Standards Incorporated by Reference in the Minimum Property Standards for Housing (HUD Handbook...

    Science.gov (United States)

    2010-04-01

    ... 19103, Telephone (215) 299-5400. ASTM C 12-91 Standard Practice for Installing Vitrified Clay Pipe Lines... C 216-91c Standard Specification for Facing Brick (Solid Masonry Units Made from Clay or Shale) ASTM.../78 77a Cast Iron Sanitary Drainage System with Hubless Pipe and Fittings—3/28/80 78 Polyethylene (PE...

  12. Vacuum decay container/closure integrity testing technology. Part 1. ASTM F2338-09 precision and bias studies.

    Science.gov (United States)

    Wolf, Heinz; Stauffer, Tony; Chen, Shu-Chen Y; Lee, Yoojin; Forster, Ronald; Ludzinski, Miron; Kamat, Madhav; Godorov, Phillip; Guazzo, Dana Morton

    2009-01-01

    ASTM F2338-09 Standard Test Method for Nondestructive Detection of Leaks in Packages by Vacuum Decay Method is applicable for leak-testing rigid and semi-rigid non-lidded trays; trays or cups sealed with porous barrier lidding materials; rigid, nonporous packages; and flexible, nonporous packages. Part 1 of this series describes the precision and bias studies performed in 2008 to expand this method's scope to include rigid, nonporous packages completely or partially filled with liquid. Round robin tests using three VeriPac 325/LV vacuum decay leak testers (Packaging Technologies & Inspection, LLC, Tuckahoe, NY) were performed at three test sites. Test packages were 1-mL glass syringes. Positive controls had laser-drilled holes in the barrel ranging from about 5 to 15 microm in nominal diameter. Two different leak tests methods were performed at each site: a "gas leak test" performed at 250 mbar (absolute) and a "liquid leak test" performed at about 1 mbar (absolute). The gas leak test was used to test empty, air-filled syringes. All defects with holes > or = 5.0 microm and all no-defect controls were correctly identified. The only false negative result was attributed to a single syringe with a ASTM F2338-09 test method and the precision and bias study report are available by contacting ASTM International in West Conshohocken, PA, USA (www.astm.org).

  13. Standard Guide for Testing Polymer Matrix Composite Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This guide summarizes the application of ASTM standard test methods (and other supporting standards) to continuous-fiber reinforced polymer matrix composite materials. The most commonly used or most applicable ASTM standards are included, emphasizing use of standards of Committee D30 on Composite Materials. 1.2 This guide does not cover all possible standards that could apply to polymer matrix composites and restricts discussion to the documented scope. Commonly used but non-standard industry extensions of test method scopes, such as application of static test methods to fatigue testing, are not discussed. A more complete summary of general composite testing standards, including non-ASTM test methods, is included in the Composite Materials Handbook (MIL-HDBK-17). Additional specific recommendations for testing textile (fabric, braided) composites are contained in Guide D6856. 1.3 This guide does not specify a system of measurement; the systems specified within each of the referenced standards shall appl...

  14. Characterization of ASTM round-robin tungsten-powder samples

    International Nuclear Information System (INIS)

    Slettevold, C.A.; Biermann, A.H.

    1975-01-01

    The Lawrence Livermore Laboratory Particle Characterization Laboratory Group has participated in an industry-wide round-robin investigation on characterization of tungsten powder. sponsored by the ASTM Subcommittee on Refractory-Metal Powders (B-09.3). The analyses performed at the suggestion of the ASTM subcommittee included measurements of tap density, apparent density, true density, average particle size, and surface area. Determinations of particle-weight and size distributions were also performed and particle inspection conducted by microscopy. This report describes the equipment and procedures used and summarizes the results of these analyses. (9 tables, 17 fig) (U.S.)

  15. 77 FR 37587 - Updating OSHA Standards Based on National Consensus Standards; Head Protection

    Science.gov (United States)

    2012-06-22

    ... Z89.1-2003 as Appendix E, to the main text. Adds ``ASTM E1164-02 Colorimetry--Standard Practice for... National complete citations for standards on Standards Referred to in This colorimetry, headforms, and...

  16. 77 FR 37617 - Updating OSHA Standards Based on National Consensus Standards; Head Protection

    Science.gov (United States)

    2012-06-22

    ... Z89.1-2003 as Appendix E, to the main text. Adds ``ASTM E1164-02 Colorimetry--Standard Practice for... National complete citations for standards on Standards Referred to in This colorimetry, headforms, and...

  17. 75 FR 30440 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM International

    Science.gov (United States)

    2010-06-01

    ... Production Act of 1993--ASTM International Notice is hereby given that, on May 6, 2010, pursuant to Section 6... Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with the Attorney... recovery of antitrust plaintiffs to actual damages under specified circumstances. Specifically, ASTM has...

  18. Chronic ankle pain and fibrosis successfully treated with a new noninvasive augmented soft tissue mobilization technique (ASTM): a case report.

    Science.gov (United States)

    Melham, T J; Sevier, T L; Malnofski, M J; Wilson, J K; Helfst, R H

    1998-06-01

    This clinical case report demonstrates the clinical effectiveness of a new form of soft tissue mobilization in the treatment of excessive connective tissue fibrosis (scar tissue) around an athlete's injured ankle. The scar tissue was causing the athlete to have pain with activity, pain on palpation of the ankle, decreased range of motion, and loss of function. Surgery and several months of conventional physical therapy failed to alleviate the athlete's symptoms. As a final resort, augmented soft tissue mobilization (ASTM) was administered. ASTM is an alternative nonsurgical treatment modality that is being researched at Performance Dynamics (Muncip, IN). ASTM is a process that uses ergonomically designed instruments that assist therapists in the rapid localization and effective treatment of areas exhibiting excessive soft tissue fibrosis. This is followed by a stretching and strengthening program. Upon the completion of 6 wk of ASTM therapy, the athlete had no pain and had regained full range of motion and function. This case report is an example of how a noninvasive augmented form of soft tissue mobilization (ASTM) demonstrated impressive clinical results in treating a condition caused by connective tissue fibrosis.

  19. Corrosion resistance and microstructure of alloy 625 weld overlay on ASTM A516 grade 70

    Energy Technology Data Exchange (ETDEWEB)

    Moradi, Mohammad J. [Amirkabir Univ. of Technology, Tehran (Iran, Islamic Republic of). Petroleum Engineering Dept.; Ketabchi, Mostafa [Amirkabir Univ. of Technology, Tehran (Iran, Islamic Republic of). Mining and Metallurgical Engineering Dept.

    2016-02-01

    Nickel-based alloys are a crucial class of materials because of their excellent corrosion resistance. In the present study, single layer and two layers alloy 625 weld overlays were deposited by GTAW process on A516 grade 70 carbon steel. The dilution in terms of Fe, Ni, Mo and Nb content was calculated in 30 points of weld overlay. Microstructure observations showed that alloy 625 had austenitic structure with two types of Laves and NbC secondary phases. The uniform and pitting corrosion resistance of alloy 625 weld overlay as casted and as forged were evaluated in accordance with ASTM G48-2011 standard at different temperatures to determine the weight loss and critical pitting temperature. For achieving a better comparison, samples from alloy 625 as casted and as forged were tested under the same conditions. The results point out that single layer alloy 625 weld overlay is not suitable for chloride containing environments, two layers alloy 625 weld overlay and alloy 625 as casted have acceptable corrosion resistance and almost the same critical pitting temperature. Alloy 625 as forged has the best corrosion resistance and the highest critical pitting temperature among all test specimens. Also, the corrosion behavior was evaluated in accordance with ASTM G28 standard. The corrosion rate of single layer weld overlay was unacceptable. The average corrosion rate of two layers weld overlay and in casted condition were 35.82 and 33.01 mpy, respectively. [German] Nickellegierungen sind aufgrund ihres exzellenten Korrosionswiderstandes eine bedeutende Werkstoffklasse. In der diesem Beitrag zugrunde liegenden Studie wurden mittels WIG-Schweissens ein- und zweilagige Schweissplattierungen auf den Kohlenstoffstahl A516 (Grade 70) aufgebracht. Die Vermischung in Form des Fe-, Ni-, Mo- und Nb-Gehaltes wurde an 30 Punkten der Schweissplattierungen berechnet. Die mikrostrukturellen Untersuchungen ergaben, dass die Legierung 625 eine austenitische Struktur mit zwei Arten von

  20. 76 FR 1459 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM International

    Science.gov (United States)

    2011-01-10

    ... Production Act of 1993-ASTM International Notice is hereby given that, on December 6, 2010, pursuant to.... (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with the...

  1. Fracture toughness of welded joints of ASTM A543 steel plate

    International Nuclear Information System (INIS)

    Susukida, H.; Uebayashi, T.; Yoshida, K.; Ando, Y.

    1977-01-01

    Fracture toughness and weldability tests have been performed on a high strength steel which is a modification of ASTM A543 Grade B Class 1 steel, with a view to using it for nuclear reactor containment vessels. The results showed that fracture toughness of welded joints of ASTM A543 modified high strength steel is superior and the steel is suitable for manufacturing the containment vessels

  2. 78 FR 21850 - Federal Motor Vehicle Safety Standards; Matters Incorporated by Reference

    Science.gov (United States)

    2013-04-12

    ... to the 1985 Annual Book of ASTM Standards, Vol. 05.04, ``Test Methods for Rating Motor, Diesel... for Rating Motor, Diesel, Aviation Fuels, A2. Reference Materials and Blending Accessories, (``ASTM... [Docket No. NHTSA-2011-0185] RIN 2127-AL25 Federal Motor Vehicle Safety Standards; Matters Incorporated by...

  3. Improved ASTM G72 Test Method for Ensuring Adequate Fuel-to-Oxidizer Ratios

    Science.gov (United States)

    Juarez, Alfredo; Harper, Susana Tapia

    2016-01-01

    The ASTM G72/G72M-15 Standard Test Method for Autogenous Ignition Temperature of Liquids and Solids in a High-Pressure Oxygen-Enriched Environment is currently used to evaluate materials for the ignition susceptibility driven by exposure to external heat in an enriched oxygen environment. Testing performed on highly volatile liquids such as cleaning solvents has proven problematic due to inconsistent test results (non-ignitions). Non-ignition results can be misinterpreted as favorable oxygen compatibility, although they are more likely associated with inadequate fuel-to-oxidizer ratios. Forced evaporation during purging and inadequate sample size were identified as two potential causes for inadequate available sample material during testing. In an effort to maintain adequate fuel-to-oxidizer ratios within the reaction vessel during test, several parameters were considered, including sample size, pretest sample chilling, pretest purging, and test pressure. Tests on a variety of solvents exhibiting a range of volatilities are presented in this paper. A proposed improvement to the standard test protocol as a result of this evaluation is also presented. Execution of the final proposed improved test protocol outlines an incremental step method of determining optimal conditions using increased sample sizes while considering test system safety limits. The proposed improved test method increases confidence in results obtained by utilizing the ASTM G72 autogenous ignition temperature test method and can aid in the oxygen compatibility assessment of highly volatile liquids and other conditions that may lead to false non-ignition results.

  4. ASTM E 1559 method for measuring material outgassing/deposition kinetics has applications to aerospace, electronics, and semiconductor industries

    Science.gov (United States)

    Garrett, J. W.; Glassford, A. P. M.; Steakley, J. M.

    1994-01-01

    The American Society for Testing and Materials has published a new standard test method for characterizing time and temperature-dependence of material outgassing kinetics and the deposition kinetics of outgassed species on surfaces at various temperatures. This new ASTM standard, E 1559(1), uses the quartz crystal microbalance (QCM) collection measurement approach. The test method was originally developed under a program sponsored by the United States Air Force Materials Laboratory (AFML) to create a standard test method for obtaining outgassing and deposition kinetics data for spacecraft materials. Standardization by ASTM recognizes that the method has applications beyond aerospace. In particular, the method will provide data of use to the electronics, semiconductor, and high vacuum industries. In ASTM E 1559 the material sample is held in vacuum in a temperature-controlled effusion cell, while its outgassing flux impinges on several QCM's which view the orifice of the effusion cell. Sample isothermal total mass loss (TML) is measured as a function of time from the mass collected on one of the QCM's which is cooled by liquid nitrogen, and the view factor from this QCM to the cell. The amount of outgassed volatile condensable material (VCM) on surfaces at higher temperatures is measured as a function of time during the isothermal outgassing test by controlling the temperatures of the remaining QCM's to selected values. The VCM on surfaces at temperatures in between those of the collector QCM's is determined at the end of the isothermal test by heating the QCM's at a controlled rate and measuring the mass loss from the end of the QCM's as a function of time and temperature. This reevaporation of the deposit collected on the QCM's is referred to as QCM thermogravimetric analysis. Isothermal outgassing and deposition rates can be determined by differentiating the isothermal TML and VCM data, respectively, while the evaporation rates of the species can be obtained as a

  5. Verification of the ASTM G-124 Purge Equation

    Science.gov (United States)

    Robbins, Katherine E.; Davis, Samuel Eddie

    2009-01-01

    ASTM G-124 seeks to evaluate combustion characteristics of metals in high-purity (greater than 99%) oxygen atmospheres. ASTM G-124 provides the following equation to determine the minimum number of purges required to reach this level of purity in a test chamber: n = -4/log10(Pa/Ph), where "n" is the total number of purge cycles required, Ph is the absolute pressure used for the purge on each cycle and Pa is the atmospheric pressure or the vent pressure. The origin of this equation is not known and has been the source of frequent questions as to its accuracy and reliability. This paper shows the derivation of the G-124 purge equation, and experimentally explores the equation to determine if it accurately predicts the number of cycles required.

  6. 78 FR 79319 - Amendment to Standards and Practices for All Appropriate Inquiries Under CERCLA

    Science.gov (United States)

    2013-12-30

    ... Standard? The ASTM E1527-13 standard is similar to the ASTM E1527-05 standard in format, process, and areas... under Section 553 of the Administrative Procedure Act (APA) for this revision to become effective immediately. Section 553(d)(3) of the APA allows an effective date less than 30 days after publication ``as...

  7. Comparative study between EDXRF and ASTM E572 methods using two-way ANOVA

    Science.gov (United States)

    Krummenauer, A.; Veit, H. M.; Zoppas-Ferreira, J.

    2018-03-01

    Comparison with reference method is one of the necessary requirements for the validation of non-standard methods. This comparison was made using the experiment planning technique with two-way ANOVA. In ANOVA, the results obtained using the EDXRF method, to be validated, were compared with the results obtained using the ASTM E572-13 standard test method. Fisher's tests (F-test) were used to comparative study between of the elements: molybdenum, niobium, copper, nickel, manganese, chromium and vanadium. All F-tests of the elements indicate that the null hypothesis (Ho) has not been rejected. As a result, there is no significant difference between the methods compared. Therefore, according to this study, it is concluded that the EDXRF method was approved in this method comparison requirement.

  8. Evaluation of Instrumentation for Measuring Undissolved Water in Aviation Turbine Fuels per ASTM D3240

    Science.gov (United States)

    2015-11-05

    Undissolved Water in Aviation Turbine Fuels per ASTM D3240 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Joel Schmitigal... water ) in Aviation Turbine Fuels per ASTM D3240 15. SUBJECT TERMS fuel, JP-8, aviation fuel, contamination, free water , undissolved water , Aqua-Glo 16...Michigan 48397-5000 Evaluation of Instrumentation for Measuring Undissolved Water in Aviation Turbine Fuels per ASTM D3240 Joel Schmitigal Force

  9. White Paper Summary of 2nd ASTM International Workshop on Hydrides in Zirconium Alloy Cladding

    Energy Technology Data Exchange (ETDEWEB)

    Sindelar, R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Louthan, M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); PNNL, B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-05-29

    This white paper recommends that ASTM International develop standards to address the potential impact of hydrides on the long term performance of irradiated zirconium alloys. The need for such standards was apparent during the 2nd ASTM International Workshop on Hydrides in Zirconium Alloy Cladding and Assembly Components, sponsored by ASTM International Committee C26.13 and held on June 10-12, 2014, in Jackson, Wyoming. The potentially adverse impacts of hydrogen and hydrides on the long term performance of irradiated zirconium-alloy cladding on used fuel were shown to depend on multiple factors such as alloy chemistry and processing, irradiation and post irradiation history, residual and applied stresses and stress states, and the service environment. These factors determine the hydrogen content and hydride morphology in the alloy, which, in turn, influence the response of the alloy to the thermo-mechanical conditions imposed (and anticipated) during storage, transport and disposal of used nuclear fuel. Workshop presentations and discussions showed that although hydrogen/hydride induced degradation of zirconium alloys may be of concern, the potential for occurrence and the extent of anticipated degradation vary throughout the nuclear industry because of the variations in hydrogen content, hydride morphology, alloy chemistry and irradiation conditions. The tools and techniques used to characterize hydrides and hydride morphologies and their impacts on material performance also vary. Such variations make site-to-site comparisons of test results and observations difficult. There is no consensus that a single material or system characteristic (e.g., reactor type, burnup, hydrogen content, end-of life stress, alloy type, drying temperature, etc.) is an effective predictor of material response during long term storage or of performance after long term storage. Multi-variable correlations made for one alloy may not represent the behavior of another alloy exposed to

  10. Overview (this manuscript is an overview of an ASTM symposium. The authors, John Sebroski and Mark Mason, of the overview were the co-chairs of the symposium and co-editors of the manuscripts submitted for ASTM peer review and subsequent publication in the technical proceedings for the symposium)

    Science.gov (United States)

    The Symposium on Developing Consensus Standards for Measuring Chemical Emissions from Spray Polyurethane Foam (SPF) Insulation was held on April 30th and May 1, 2015. Sponsored by ASTM Committee D22 on Air Quality, the symposium was held in Anaheim, CA, in conjunction with the st...

  11. Nuclear reactor pressure vessel surveillance capsule examinations. Application of American Society for Testing and Materials Standards

    International Nuclear Information System (INIS)

    Perrin, J.S.

    1978-01-01

    A series of pressure vessel surveillance capsules is installed in each commercial nuclear power plant in the United States. A capsule typically contains neutron dose meters, thermal monitors, tensile specimens, and Charpy V-notch impact specimens. In order to determine property changes of the pressure vessel resulting from irradiation, surveillance capsules are periodically removed during the life of a reactor and examined. There are numerous standards, regulations, and codes governing US pressure vessel surveillance capsule programmes. These are put out by the US Nuclear Regulatory Commission, the Boiler and Pressure Vessel Committee of the American Society of Mechanical Engineers, and the American Society for Testing and Materials (ASTM). A majority of the pertinent ASTM standards are under the jurisdiction of ASTM Committee E-10 on Nuclear Applications and Measurements of Radiation Effects. The standards, regulations, and codes pertaining to pressure vessel surveillance play an important role in ensuring reliability of the nuclear pressure vessels. ASTM E 185-73 is the Standard Recommended Practice for Surveillance Tests for Nuclear Reactors. This standard recommends procedures for both the irradiation and subsequent testing of surveillance capsules. ASTM E 185-73 references many additional specialized ASTM standards to be followed in specific areas of a surveillance capsule examination. A key element of surveillance capsule programmes is the Charpy V-notch impact test, used to define curves of fracture behaviour over a range of temperatures. The data from these tests are used to define the adjusted reference temperature used in determining pressure-temperature operating curves for a nuclear power plant. (author)

  12. Use of ASTM D5304 in assessing unstable diesel fuel

    Energy Technology Data Exchange (ETDEWEB)

    Turner, L.M.; Martin, C.J. [Defense Fuel Supply Center, Alexandria, VA (United States); Beal, E.J.; Hardy, D.R. [Naval Research Lab., Washington, DC (United States)

    1995-05-01

    The storage stability, or the length of time a fuel can be stored, is of great concern to diesel fuel users. This paper reports on the use of the new ASTM accelerated test for storage stability by oxygen overpressure (D5304) to predict future storage life span of 63,000,000 gallons of a diesel fuel for US Naval vessel use. This paper demonstrates the use of ASTM D5304 at storage times of 16, 40 and 96 hours to accurately determine the length of time that this large quantity of diesel fuel could be stored at ambient temperatures before the maximum allowable amount of particulate contamination was reached.

  13. Integration of Nanofluids into Commercial Antifreeze Concentrates with ASTM D15 Corrosion Testing

    Science.gov (United States)

    2013-05-01

    Lockwood1 1 Valvoline New Product Development Laboratory, Ashland Consumer Markets , Lexington, Kentucky. 2 Tank Automotive Research, Development...Development Laboratory,Ashland Consumer Markets ,P.O. Box 14000,Lexington,KY,40512 8. PERFORMING ORGANIZATION REPORT NUMBER ; #23826 9. SPONSORING...Technology, Performance, and Life for Light-Duty Applications, Engine Coolant Testing: Fourth Volume, ASTM STP 1335, R.E. Beale ed., ASTM, Philadelphia

  14. Twenty new ISO standards on dosimetry for radiation processing

    International Nuclear Information System (INIS)

    Farrar IV, H.

    2000-01-01

    Twenty standards on essentially all aspects of dosimetry for radiation processing were published as new ISO standards in December 1998. The standards are based on 20 standard practices and guides developed over the past 14 years by Subcommittee E10.01 of the American Society for Testing and Materials (ASTM). The transformation to ISO standards using the 'fast track' process under ISO Technical Committee 85 (ISO/TC85) commenced in 1995 and resulted in some overlap of technical information between three of the new standards and the existing ISO Standard 11137 Sterilization of health care products - Requirements for validation and routine control - Radiation sterilization. Although the technical information in these four standards was consistent, compromise wording in the scopes of the three new ISO standards to establish precedence for use were adopted. Two of the new ISO standards are specifically for food irradiation applications, but the majority apply to all forms of gamma, X-ray, and electron beam radiation processing, including dosimetry for sterilization of health care products and the radiation processing of fruit, vegetables, meats, spices, processed foods, plastics, inks, medical wastes, and paper. Most of the standards provide exact procedures for using individual dosimetry systems or for characterizing various types of irradiation facilities, but one covers the selection and calibration of dosimetry systems, and another covers the treatment of uncertainties using the new ISO Type A and Type B evaluations. Unfortunately, nine of the 20 standards just adopted by the ISO are not the most recent versions of these standards and are therefore already out of date. To help solve this problem, efforts are being made to develop procedures to coordinate the ASTM and ISO development and revision processes for these and future ASTM-originating dosimetry standards. In the meantime, an additional four dosimetry standards have recently been published by the ASTM but have

  15. Interlaboratory Study (ILS) for F 548-01, The Standard Test Method for Intensity of Scratches on Aerospace Transparent Plastics

    National Research Council Canada - National Science Library

    Pinkus, Alan

    2003-01-01

    ...) as outlined in ASTM E 691. This report, which conforms to the ILS reporting format required by ASTM, describes the study that was conducted for ASTM test standard F 548-01, Intensity of Scratches on Aerospace Transparent Plastics...

  16. 76 FR 78614 - Welded ASTM A-312 Stainless Steel Pipe From South Korea and Taiwan: Continuation of Antidumping...

    Science.gov (United States)

    2011-12-19

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-580-810, A-583-815] Welded ASTM A-312... revocation of the antidumping duty orders on welded ASTM A-312 stainless steel pipe from South Korea (Korea... December 30, 1992, the Department published the antidumping duty orders on welded ASTM A-312 stainless...

  17. Spray Drift Reduction Evaluations of Spray Nozzles Using a Standardized Testing Protocol

    Science.gov (United States)

    2010-07-01

    Drop Size Characteristics in a Spray Using Optical Nonimaging Light-Scattering Instruments,” Annual Book of ASTM Standards, Vol. 14-02, ASTM...Test Method for Determining Liquid Drop Size Characteristics in a Spray Using Optical Non- imaging Light-Scattering Instruments 22. AGDISP Model

  18. Sources of Confusion in the Determination of ASTM Repetitive Member Factors for the Allowable Properties of Wood Products

    Science.gov (United States)

    S. Verrill; D. Kretschmann

    2012-01-01

    It is generally accepted that there should be an upward repetitive member allowable property adjustment. ASTM D245 (2011c) and ASTM D1990 (2011b) specify a 1.15 factor for allowable bending stress. This factor is also listed in ASTM D6555 (2011a, Table 1). In this technical note, sources of confusion regarding appropriate repetitive member factors are identified. This...

  19. Cavitation erosion - corrosion behaviour of ASTM A27 runner steel in natural river water

    International Nuclear Information System (INIS)

    Tôn-Thât, L

    2014-01-01

    Cavitation erosion is still one of the most important degradation modes in hydraulic turbine runners. Part of researches in this field focuses on finding new materials, coatings and surface treatments to improve the resistance properties of runners to this phenomenon. However, only few studies are focused on the deleterious effect of the environment. Actually, in some cases a synergistic effect between cavitation erosion mechanisms and corrosion kinetics can establish and increase erosion rate. In the present study, the cavitation erosion-corrosion behaviour of ASTM A27 steel in natural river water is investigated. This paper state the approach which has been used to enlighten the synergy between both phenomena. For this, a 20 kHz vibratory test according ASTM G32 standard is coupled to an electrochemical cell to be able to follow the different corrosion parameters during the tests to get evidence of the damaging mechanism. Moreover, mass losses have been followed during the exposure time. The classical degradation parameters (cumulative weight loss and erosion rate) are determined. Furthermore, a particular effort has been implemented to determine the evolution of surface damages in terms of pitting, surface cracking, material removal and surface corrosion. For this, scanning electron microscopy has been used to link the microstructure to the material removal mechanisms

  20. 76 FR 67673 - Welded ASTM A-312 Stainless Steel Pipe From South Korea and Taiwan: Final Results of Expedited...

    Science.gov (United States)

    2011-11-02

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-580-810, A-583-815] Welded ASTM A-312... the antidumping duty orders on welded ASTM A-312 stainless steel pipe from South Korea and Taiwan... duty orders on welded ASTM A-312 stainless steel pipe from South Korea and Taiwan pursuant to section...

  1. A Knowledge- Based Computer System for UO2 Characterization According to ASTM Requirements

    International Nuclear Information System (INIS)

    Afifi, Y.K.; El-Hakim, E.

    2000-01-01

    The uranium dioxde (UO 2 ) powder properties and the pellets fabrication processes determine the characteristics of the sintered UO 2 pellets. The powder properties include chemical and physical characteristics. The physical and chemical properties of UO 2 powder are normally checked to ensure consistency and reproducibility of the sintered UO 2 pellets. Powder characteristics are known to influence the subsequent manufacturing performance or the fuel properties. The aim of this paper is to provide the nuclear industry with a program dealing with the processes and the related requirements to determine the specifications of UO 2 powder according to the American Standards for Testing and Materials (ASTM). This program covers the physical and chemical characteristics of UO 2 powder. A group of logic flow charts dealing with the data and information available in the ASTM for each step in the characterization of UO 2 powder process and the technical assistance are constructed. These logic flow charts are collected to form a module of the software to qualify the UO 2 powder. The program contains 8 modules, each one deals with one object. This program saves time, is also considered as a collective schema for all the required UO 2 powder characterization and the related processes, and could be used as a training tool for less skilled personnel involved in UO 2 powder characterization laboratories

  2. An Automated Safe-to-Mate (ASTM) Tester

    Science.gov (United States)

    Nguyen, Phuc; Scott, Michelle; Leung, Alan; Lin, Michael; Johnson, Thomas

    2013-01-01

    Safe-to-mate testing is a common hardware safety practice where impedance measurements are made on unpowered hardware to verify isolation, continuity, or impedance between pins of an interface connector. A computer-based instrumentation solution has been developed to resolve issues. The ASTM is connected to the circuit under test, and can then quickly, safely, and reliably safe-to-mate the entire connector, or even multiple connectors, at the same time.

  3. Stress corrosion (Astm G30-90 standard) in 08x18H10T stainless steel of nuclear fuel storage pool in WWER reactors; Corrosion bajo esfuerzo (Norma ASTM G30-90) en acero inoxidable 08x18H10T de piscinas de almacenamiento de combustible nuclear en reactores V.V.E.R

    Energy Technology Data Exchange (ETDEWEB)

    Herrera, V.; Zamora R, L. [Centro de Estudios Aplicados al Desarrollo Nuclear (Cuba)

    1997-07-01

    At the water storage of the irradiated nuclear fuel has been an important factor in its management. The actual pools have its walls covered with inoxidable steel and heat exchangers to dissipate the residual heat from fuel. It is essential to control the water purity to eliminate those conditions which aid to the corrosion process in fuel and at related components. The steel used in this research was obtained from an austenitic inoxidizable steel standardized with titanium 08x18H10T (Type 321) similar to one of the two steel coatings used to cover walls and the pools floor. the test consisted in the specimen deformation through an U ply according to the Astm G30-90 standard. The exposition of the deformed specimen it was realized in simulated conditions to the chemical regime used in pools. (Author)

  4. Combating Wear of ASTM A36 Steel by Surface Modification Using Thermally Sprayed Cermet Coatings

    Directory of Open Access Journals (Sweden)

    Vineet Shibe

    2016-01-01

    Full Text Available Thermal spray coatings can be applied economically on machine parts to enhance their requisite surface properties like wear, corrosion, erosion resistance, and so forth. Detonation gun (D-Gun thermal spray coatings can be applied on the surface of carbon steels to improve their wear resistance. In the present study, alloy powder cermet coatings WC-12% Co and Cr3C2-25% NiCr have been deposited on ASTM A36 steel with D-Gun thermal spray technique. Sliding wear behavior of uncoated ASTM A36 steel and D-Gun sprayed WC-12% Co and Cr3C2-25% NiCr coatings on base material is observed on a Pin-On-Disc Wear Tester. Sliding wear performance of WC-12% Co coating is found to be better than the Cr3C2-25% NiCr coating. Wear performance of both these cermet coatings is found to be better than uncoated ASTM A36 steel. Thermally sprayed WC-12% Co and Cr3C2-25% NiCr cermet coatings using D-Gun thermal spray technique is found to be very useful in improving the sliding wear resistance of ASTM A36 steel.

  5. Impact of heat treatment on HSS cutting tool (ASTM A600) and its behaviour during machining of mild steel (ASTM A36)

    Science.gov (United States)

    Afolalu, S. A.; Abioye, O. P.; Salawu, E. Y.; Okokpujie, I. P.; Abioye, A. A.; Omotosho, O. A.; Ajayi., O. O.

    2018-04-01

    Carburization is one the best heat treatment that responded well to hardening with Palm Kernel Shell giving the best hardness value. This work studied the influence of carburization on HSStool(ASTM A600) and its behaviour during machining of mild steel (ASTM A36). Composition of the samples (12 pieces of 180 × 12 × 12 mm) HSS tools were checked using UV-VIS spectrometer and the tools were carburized with PKS at holding temperatures and time of 800, 850, 900, 950 °C and 60,90 120 minutes using muffle furnance. The micro structural analysis, surface and core hardnessof the treated samples gave better results than the untreated samples when checked withsoft driven and optical microscope. It wasalso observed that increase in the feed rate and depth for length of cut of 50 mm significantly reduces the wear progression and thereby gave best machining time at maximum carburizing temperature and time(950 °C / 120 minutes) when it was used to cut mild steelon the lathe machine.

  6. JST Thesaurus Headwords and Synonyms: ASTM [MeCab user dictionary for science technology term[Archive

    Lifescience Database Archive (English)

    Full Text Available MeCab user dictionary for science technology term ASTM 名詞 一般 * * * * 米国材料試験協会 ベイコクザ...イリョウシケンキョウカイ ベイコクザイリョーシケンキョーカイ Thesaurus2015 200906091611619997 C IA02 UNKNOWN_1 ASTM

  7. Ductile fracture toughness of heavy section pressure vessel steel plate. A specimen-size study of ASTM A 533 steels

    International Nuclear Information System (INIS)

    Williams, J.A.

    1979-09-01

    The ductile fracture toughness, J/sub Ic/, of ASTM A 533, Grade B, Class 1 and ASTM A 533, heat treated to simulate irradiation, was determined for 10- to 100-mm thick compact specimens. The toughness at maximum specimen load was also measured to determine the conservatism of J/sub Ic/. The toughness of ASTM A 533, Grade B, Class 1 steel was 349 kJ/m 2 and at the equivalent upper shelf temperature, the heat treated material exhibited 87 kJ/m 2 . The maximum load fracture toughness was found to be linearly proportional to specimen size, and only specimens which failed to meet ASTM size criteria exhibited maximum load toughness less than J/sub Ic/

  8. An Experimental Copyright Moratorium: Study of a Proposed Solution to the Copyright Photocopying Problem. Final Report to the American Society for Testing and Materials (ASTM).

    Science.gov (United States)

    Heilprin, Laurence B.

    The Committee to Investigate Copyright Problems (CICP), a non-profit organization dedicated to resolving the conflict known as the "copyright photocopying problem" was joined by the American Society for Testing and Materials (ASTM), a large national publisher of technical and scientific standards, in a plan to simulate a long-proposed…

  9. 75 FR 70074 - Consensus Standards, Light-Sport Aircraft

    Science.gov (United States)

    2010-11-16

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Consensus Standards, Light-Sport... accepted consensus standards relating to the provisions of the Sport Pilot and Light-Sport Aircraft rule issued July 16, 2004, and effective September 1, 2004. ASTM International Committee F37 on Light Sport...

  10. Data development for ASTM E24.06.02 round robin program on instability prediction

    Science.gov (United States)

    Mccabe, D. E.

    1979-01-01

    Basis data for use in an ASTM E24.06.02 task group round robin activity was developed. Compact specimens were made of 2024-T351, 7075-T651 aluminum alloys, and 304 stainless steel. All were 12.7 mm thick and planar dimension variables incorporated were for 1T, 2T and 4T sizes. Representative raw data for each material and specimen size are contained herein. R-curves plotted in terms of delta a physical and delta a effective are plotted for each material.

  11. Isothermal Bainite Processing of ASTM A723 Components

    Science.gov (United States)

    1993-09-01

    4 List of Illustrations 1. Photograph of typical cylinders used in the present study ................................. 7 2. CCT diagram for... CCT ) diagram obtained by thermal and magnetic analyses for the high nickel (-3 percent) ASTM A723 steel. The bainite knee for the 2 percent nickel...block. Also shown is the slope giving the average cooling rate in the critical region of the CCT diagram . This average rate happens to approximately

  12. 78 FR 13243 - Updates to Standards Incorporated by Reference; Reapproved ASTM Standards; Technical Amendment

    Science.gov (United States)

    2013-02-27

    ... Characteristics of Plastic Film 2009)[egr]1. and Sheeting. Standard Specification for F682-82a F682-82a 46 56.01-2... (Reapproved Standard Test Method for Determining Gas 2009)[egr]1. Permeability Characteristics of Plastic Film... Permeability Characteristics of Plastic Film and Sheeting (approved May 1, 2009), incorporation by reference...

  13. Cor ASTM: um método simples e rápido para determinar a qualidade do biodiesel produzido a partir de óleos residuais de fritura ASTM color: a simple and fast method for determining quality of biodiesel produced from used cooking oils

    Directory of Open Access Journals (Sweden)

    Verônica Santos de Morais

    2013-01-01

    Full Text Available In this study, 23 biodiesel samples were produced, 20 from used cooking oil and the remaining 3 from refined soybean oil. The following properties were determined in all of the samples (oil and its respective biodiesel: density; viscosity; total acid number and ASTM color. The results indicated high correlation (R > 0.6 between ASTM color of used cooking oil and total acid number of its resultant biodiesel. This high correlation allows prediction of the quality of the biodiesel produced using a simple and fast procedure such as ASTM color.

  14. 75 FR 48593 - Pipeline Safety: Periodic Updates of Regulatory References to Technical Standards and...

    Science.gov (United States)

    2010-08-11

    ... (ASTM): ASTM A53/A53M-07 (2007), ``Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless'' (September 1, 2007). Replaces IBR: 2004 edition; Referenced in 49 CFR 192...), we clarify that cast iron, malleable iron, or ductile iron may be used in the valve ball or plug...

  15. Final Report, Volume 2, The Development of Qualification Standards for Cast Duplex Stainless Steel

    Energy Technology Data Exchange (ETDEWEB)

    Russell, Steven, W.; Lundin, Carl, D.

    2005-09-30

    The scope of testing cast Duplex Stainless Steel (DSS) required testing to several ASTM specifications, while formulating and conducting industry round robin tests to verify and study the reproducibility of the results. ASTM E562 (Standard Test Method for Determining Volume Fraction by Systematic manual Point Count) and ASTM A923 (Standard Test Methods for Detecting Detrimental Intermetallic Phase in Wrought Duplex Austenitic/Ferritic Stainless Steels) were the specifications utilized in conducting this work. An ASTM E562 industry round robin, ASTM A923 applicability study, ASTM A923 industry round robin, and an ASTM A923 study of the effectiveness of existing foundry solution annealing procedures for producing cast DSS without intermetallic phases were implemented. In the ASTM E562 study, 5 samples were extracted from various cast austenitic and DSS in order to have varying amounts of ferrite. Each sample was metallographically prepared by UT and sent to each of 8 participants for volume fraction of ferrite measurements. Volume fraction of ferrite was measured using manual point count per ASTM E562. FN was measured from the Feritescope{reg_sign} and converted to volume fraction of ferrite. Results indicate that ASTM E562 is applicable to DSS and the results have excellent lab-to-lab reproducibility. Also, volume fraction of ferrite conversions from the FN measured by the Feritescope{reg_sign} were similar to volume fraction of ferrite measured per ASTM E562. In the ASTM A923 applicability to cast DSS study, 8 different heat treatments were performed on 3 lots of ASTM A890-4A (CD3MN) castings and 1 lot of 2205 wrought DSS. The heat treatments were selected to produce a wide range of cooling rates and hold times in order to study the suitability of ASTM A923 to the response of varying amounts on intermetallic phases [117]. The test parameters were identical to those used to develop ASTM A923 for wrought DSS. Charpy V-notch impact samples were extracted from the

  16. Final Report, Volume 2, The Development of Qualification Standards for Cast Duplex Stainless Steel

    Energy Technology Data Exchange (ETDEWEB)

    Russell, Steven, W.; Lundin, Carl, W.

    2005-09-30

    The scope of testing cast Duplex Stainless Steel (DSS) required testing to several ASTM specifications, while formulating and conducting industry round robin tests to verify and study the reproducibility of the results. ASTM E562 (Standard Test Method for Determining Volume Fraction by Systematic manual Point Count) and ASTM A923 (Standard Test Methods for Detecting Detrimental Intermetallic Phase in Wrought Duplex Austenitic/Ferritic Stainless Steels) were the specifications utilized in conducting this work. An ASTM E562 industry round robin, ASTM A923 applicability study, ASTM A923 industry round robin, and an ASTM A923 study of the effectiveness of existing foundry solution annealing procedures for producing cast DSS without intermetallic phases were implemented. In the ASTM E562 study, 5 samples were extracted from various cast austenitic and DSS in order to have varying amounts of ferrite. Each sample was metallographically prepared by UT and sent to each of 8 participants for volume fraction of ferrite measurements. Volume fraction of ferrite was measured using manual point count per ASTM E562. FN was measured from the Feritescope® and converted to volume fraction of ferrite. Results indicate that ASTM E562 is applicable to DSS and the results have excellent lab-to-lab reproducibility. Also, volume fraction of ferrite conversions from the FN measured by the Feritescope® were similar to volume fraction of ferrite measured per ASTM E562. In the ASTM A923 applicability to cast DSS study, 8 different heat treatments were performed on 3 lots of ASTM A890-4A (CD3MN) castings and 1 lot of 2205 wrought DSS. The heat treatments were selected to produce a wide range of cooling rates and hold times in order to study the suitability of ASTM A923 to the response of varying amounts on intermetallic phases [117]. The test parameters were identical to those used to develop ASTM A923 for wrought DSS. Charpy V-notch impact samples were extracted from the castings and wrought

  17. 46 CFR 164.015-1 - Applicable specifications and standards.

    Science.gov (United States)

    2010-10-01

    ..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL MATERIALS Plastic Foam, Unicellular, Buoyant, Sheet... following specification and standard, of the issue in effect on the date the plastic foam material is...) ASTM D4986-98, Standard Test Method for Horizontal Burning Characteristics of Cellular Polymeric...

  18. The Trends and Prospects of Health Information Standards : Standardization Analysis and Suggestions

    International Nuclear Information System (INIS)

    Kim, Chang Soo

    2008-01-01

    Ubiquitous health care system, which is one of the developing solution technologies of IT, BT and NT, could give us new medical environments in future. Implementing health information systems can be complex, expensive and frustrating. Healthcare professionals seeking to acquire or upgrade systems do not have a convenient, reliable way of specifying a level of adherence to communication standards sufficient to achieve truly efficient interoperability. Great progress has been made in establishing such standards-DICOM, IHE and HL7, notably, are now highly advanced. IHE has defined a common framework to deliver the basic interoperability needed for local and regional health information networks. It has developed a foundational set of standards-based integration profiles for information exchange with three interrelated efforts. HL7 is one of several ANSI-accredited Standards Developing Organizations operating in the healthcare arena. Most SDOs produce standards (protocols) for a particular healthcare domain such as pharmacy, medical devices, imaging or insurance transactions. HL7's domain is clinical and administrative data. HL7 is an international community of healthcare subject matter experts and information scientists collaborating to create standards for the exchange, management and integration of electronic healthcare information. The ASTM specification for Continuity of Care Record was developed by subcommittee E31.28 on electronic health records, which includes clinicians, provider institutions, administrators, patient advocates, vendors, and health industry. In this paper, there are suggestions that provide a test bed, demonstration and specification of how standards such a IHE, HL7, ASTM can be used to provide an integrated environment.

  19. The Trends and Prospects of Health Information Standards : Standardization Analysis and Suggestions

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Soo [Dept. of Radiological Science, College of Health Science, Catholic University of Pusan, Pusan (Korea, Republic of)

    2008-03-15

    Ubiquitous health care system, which is one of the developing solution technologies of IT, BT and NT, could give us new medical environments in future. Implementing health information systems can be complex, expensive and frustrating. Healthcare professionals seeking to acquire or upgrade systems do not have a convenient, reliable way of specifying a level of adherence to communication standards sufficient to achieve truly efficient interoperability. Great progress has been made in establishing such standards-DICOM, IHE and HL7, notably, are now highly advanced. IHE has defined a common framework to deliver the basic interoperability needed for local and regional health information networks. It has developed a foundational set of standards-based integration profiles for information exchange with three interrelated efforts. HL7 is one of several ANSI-accredited Standards Developing Organizations operating in the healthcare arena. Most SDOs produce standards (protocols) for a particular healthcare domain such as pharmacy, medical devices, imaging or insurance transactions. HL7's domain is clinical and administrative data. HL7 is an international community of healthcare subject matter experts and information scientists collaborating to create standards for the exchange, management and integration of electronic healthcare information. The ASTM specification for Continuity of Care Record was developed by subcommittee E31.28 on electronic health records, which includes clinicians, provider institutions, administrators, patient advocates, vendors, and health industry. In this paper, there are suggestions that provide a test bed, demonstration and specification of how standards such a IHE, HL7, ASTM can be used to provide an integrated environment.

  20. Combating Wear of ASTM A36 Steel by Surface Modification Using Thermally Sprayed Cermet Coatings

    OpenAIRE

    Shibe, Vineet; Chawla, Vikas

    2016-01-01

    Thermal spray coatings can be applied economically on machine parts to enhance their requisite surface properties like wear, corrosion, erosion resistance, and so forth. Detonation gun (D-Gun) thermal spray coatings can be applied on the surface of carbon steels to improve their wear resistance. In the present study, alloy powder cermet coatings WC-12% Co and Cr3C2-25% NiCr have been deposited on ASTM A36 steel with D-Gun thermal spray technique. Sliding wear behavior of uncoated ASTM A36 ste...

  1. 76 FR 47555 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line and Pressure Pipe From Japan...

    Science.gov (United States)

    2011-08-05

    ... Engineers (``ASME'') code stress levels. Alloy pipes made to ASTM A-335 standard must be used if temperatures and stress levels exceed those allowed for ASTM A-106. Seamless pressure pipes sold in the United..., or pressure pipe applications. B. Finished and unfinished oil country tubular goods (``OCTG''), if...

  2. Experimental and numerical study of a modified ASTM C633 adhesion test for strongly-bonded coatings

    Energy Technology Data Exchange (ETDEWEB)

    Bernardie, Raphaëlle; Berkouch, Reda; Valette, Stéphane; Absi, Joseph; Lefort, Pierre [University of Limoges, Limoges Cedex (France)

    2017-07-15

    When coatings are strongly bonded to their substrates it is often difficult to measure the adhesion values. The proposed method, which is suggested naming “silver print test”, consists in covering the central part of the samples with a thin layer of silver paint, before coating. The process used for testing this new method was the Air plasma spraying (APS), and the materials used were alumina coatings on C35 steel substrates, previously pre-oxidized in CO{sub 2}. The silver painted area was composed of small grains that did not oxidize but that significantly sintered during the APS process. The silver layer reduced the surface where the coating was linked to the substrate, which allowed its debonding, using the classical adhesion test ASTM C633-13, while the direct use of this test (without silver painting) led to ruptures inside the glue used in this test. The numerical modelling, based on the finite element method with the ABAQUS software, provided results in good agreement with the experimental measurements. This concordance validated the used method and allowed accessing to the values of adherence when the experimental test ASTM C633-13 failed, because of ruptures in the glue. After standardization, the “silver print test” might be used for other kinds of deposition methods, such as PVD, CVD, PECVD.

  3. New ASTM Standards for Nondestructive Testing of Aerospace Composites

    Science.gov (United States)

    Waller, Jess M.; Saulsberry, Regor L.

    2010-01-01

    Problem: Lack of consensus standards containing procedural detail for NDE of polymer matrix composite materials: I. Flat panel composites. II. Composite components with more complex geometries a) Pressure vessels: 1) composite overwrapped pressure vessels (COPVs). 2) composite pressure vessels (CPVs). III. Sandwich core constructions. Metal and brittle matrix composites are a possible subject of future effort.

  4. 77 FR 27428 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe (Over 41/2

    Science.gov (United States)

    2012-05-10

    ... (``ASME'') code stress levels. Alloy pipes made to ASTM A-335 standard must be used if temperatures and stress levels exceed those allowed for ASTM A-106. Seamless pressure pipes sold in the United States are..., or pressure pipe applications. B. Finished and unfinished oil country tubular goods (``OCTG''), if...

  5. 76 FR 66688 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe (Over 41/2

    Science.gov (United States)

    2011-10-27

    ... (``ASME'') code stress levels. Alloy pipes made to ASTM A-335 standard must be used if temperatures and stress levels exceed those allowed for ASTM A-106. Seamless pressure pipes sold in the United States are..., or pressure pipe applications. B. Finished and unfinished oil country tubular goods (``OCTG''), if...

  6. Comparative field permeability measurement of permeable pavements using ASTM C1701 and NCAT permeameter methods.

    Science.gov (United States)

    Li, Hui; Kayhanian, Masoud; Harvey, John T

    2013-03-30

    Fully permeable pavement is gradually gaining support as an alternative best management practice (BMP) for stormwater runoff management. As the use of these pavements increases, a definitive test method is needed to measure hydraulic performance and to evaluate clogging, both for performance studies and for assessment of permeability for construction quality assurance and maintenance needs assessment. Two of the most commonly used permeability measurement tests for porous asphalt and pervious concrete are the National Center for Asphalt Technology (NCAT) permeameter and ASTM C1701, respectively. This study was undertaken to compare measured values for both methods in the field on a variety of permeable pavements used in current practice. The field measurements were performed using six experimental section designs with different permeable pavement surface types including pervious concrete, porous asphalt and permeable interlocking concrete pavers. Multiple measurements were performed at five locations on each pavement test section. The results showed that: (i) silicone gel is a superior sealing material to prevent water leakage compared with conventional plumbing putty; (ii) both methods (NCAT and ASTM) can effectively be used to measure the permeability of all pavement types and the surface material type will not impact the measurement precision; (iii) the permeability values measured with the ASTM method were 50-90% (75% on average) lower than those measured with the NCAT method; (iv) the larger permeameter cylinder diameter used in the ASTM method improved the reliability and reduced the variability of the measured permeability. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Development and testing of standardized procedures and reference data for LWR surveillance

    International Nuclear Information System (INIS)

    McElroy, W.N.

    1979-02-01

    The resources and talents of many national and international organizations and laboratories, both governmental and industrial, are being used to establish analysis methods for predicting the embrittlement condition of light water reactor (LWR) primary systems. The exact interrelationships and responsibilities between those developing, understanding, combining, and applying state-of-the-art technology in dosimetry, metallurgy, and fracture mechanics for reactor systems analysis are being carefully reviewed and studied. This has resulted in a more comprehensive definition of the scope of new and updated ASTM standards required for the analysis and interpretation of LWR pressure vessel surveillance results. Fifteen new and updated ASTM standards have now been identified, together with a restructuring of the main interfaces between the individual standard practices, guides, and methods. The paper briefly discusses these standards and the initial results of multi-laboratory research work involved in their validation and calibration

  8. Mechanical properties of ASTM A508 Class 4 steel used in the LWBR closure head and support flange (LWBR Development Program)

    International Nuclear Information System (INIS)

    Allen, R.M.; Hall, J.F.

    1978-07-01

    The LWBR closure head and support flange are manufactured from forgings of ASTM A508 Class 4 steel rather than the ASTM A508 Class 2 forging material more commonly used in reactor vessels and closure heads. Forgings involved were approximately 300,000 pounds and 46,000 pounds. The extensive material test program conducted on ASTM A508 Class 4 LWBR forgings is described. The results of the tests confirm that the A508 Class 4 material used for the LWBR forgings has been quite good through thickness, fracture toughness, and strength properties and fully meet all specified requirements

  9. New standards for digital radiography and qualification of detectors; Neue Standards zur Digitalen Radiographie und Qualifizierung von Detektoren

    Energy Technology Data Exchange (ETDEWEB)

    Ewert, Uwe; Zscherpel, Uwe [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany)

    2017-08-01

    The contribution describes the most important standards for radiographic examinations that are revised in different committees. Information is given on new requirements esp. on revised parameters that have to be considered in practical testing procedures and classification. Actually for the revision of ISO 17636-1/2 in 2018 user questions are collected concerning weld seam testing. The DIN 25435 standards for weld seam testing in nuclear technology have been translated into English. Revisions of ASTM standards have to be considered in the actual EN and ISO standards. Since several years the International Institute of Welding (IIW) is also revising the international standards.

  10. The Status of silicosis in the world: Feedback on the ASTM Silica Symposium

    CSIR Research Space (South Africa)

    Pretorius, CJ

    2013-06-01

    Full Text Available The second ASTM Silica Symposium was held in Oct 2012 where speakers reported on the status of silicosis in their respective countries. Speakers reported on findings of research that they carried out on sampling equipment and analytical techniques...

  11. ASTM clustering for improving coal analysis by near-infrared spectroscopy.

    Science.gov (United States)

    Andrés, J M; Bona, M T

    2006-11-15

    Multivariate analysis techniques have been applied to near-infrared (NIR) spectra coals to investigate the relationship between nine coal properties (moisture (%), ash (%), volatile matter (%), fixed carbon (%), heating value (kcal/kg), carbon (%), hydrogen (%), nitrogen (%) and sulphur (%)) and the corresponding predictor variables. In this work, a whole set of coal samples was grouped into six more homogeneous clusters following the ASTM reference method for classification prior to the application of calibration methods to each coal set. The results obtained showed a considerable improvement of the error determination compared with the calibration for the whole sample set. For some groups, the established calibrations approached the quality required by the ASTM/ISO norms for laboratory analysis. To predict property values for a new coal sample it is necessary the assignation of that sample to its respective group. Thus, the discrimination and classification ability of coal samples by Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS) in the NIR range was also studied by applying Soft Independent Modelling of Class Analogy (SIMCA) and Linear Discriminant Analysis (LDA) techniques. Modelling of the groups by SIMCA led to overlapping models that cannot discriminate for unique classification. On the other hand, the application of Linear Discriminant Analysis improved the classification of the samples but not enough to be satisfactory for every group considered.

  12. 78 FR 35085 - Consensus Standards, Light-Sport Aircraft

    Science.gov (United States)

    2013-06-11

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Consensus Standards, Light-Sport... to the provisions of the Sport Pilot and Light-Sport Aircraft rule issued July 16, 2004, and effective September 1, 2004. ASTM International Committee F37 on Light Sport Aircraft developed the new and...

  13. 77 FR 24251 - Consensus Standards, Light-Sport Aircraft

    Science.gov (United States)

    2012-04-23

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Consensus Standards, Light-Sport... relating to the provisions of the Sport Pilot and Light-Sport Aircraft rule issued July 16, 2004, and effective September 1, 2004. ASTM International Committee F37 on Light Sport Aircraft developed the new and...

  14. Impact of standards and certification on environmental impairment liability insurance programs

    International Nuclear Information System (INIS)

    Gulledge, W.P.

    1993-01-01

    Environmental impairment liability (EIL) insurance is available for petroleum storage tank and other environmental exposures. Recent standards and performance criteria for leak detection for underground storage tanks (USTs) and other technical standards for USTs have been both a benefit and an interference to risk-based underwriting of storage tank EIL insurance programs. Insurance underwriters and state financial responsibility program administrators are confronted with confusing information to manage these environmental risks. Standards and certification are also key issues for site assessment programs. Recent activities from ASTM and the Institute for Environmental Auditing (IEA) have addressed the need to increase the professional stature of site assessments and environmental management. Reaction and acceptance of these efforts by the users have been mixed. Ultimately, these efforts will greatly impact insurance coverage for environmental risks

  15. Interim technical evaluation report of testing procedures for activated carbon adsorbers in ventilation filter assemblies in nuclear power plants

    International Nuclear Information System (INIS)

    Sill, C.W.; Scarpellino, C.D.; Tkachyk, J.W.; Grey, A.E.; Frank, C.W.

    1985-05-01

    Laboratory analysis of activated carbon is required by nuclear power plant technical specifications for use in Engineered Safety Feature (ESF) ventilation systems to determine the capability of those systems to remove radioiodines from air during normal operation and following a design basis accident (DBA). The lask of agreement of laboratory results from a recent round robin raised concerns regarding the adequacy of the analyses, using the ASTM D3803-79 standard, to assure compliance with plant technical specifications. EG and G Idaho was contracted by the NRC to conduct a program to provide the bases for resolving these concerns. This EG and G report serves as an interim Technical Evaluation Report (TER) of the program and presents reviews of the ASTM D3803-79 standard and the commercial testing laboratories. Results of EG and G laboratory studies and the NRC/EG and G Interlaboratory Comparison are presented with conclusions and recommendations concerning changes required to improve the standard and its application. Possible revisions to plant technical specifications required to reflect the true capability of activated carbon to remove radioiodines are also presented

  16. Standard practice for preparation and use of direct tension stress-corrosion test specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This practice covers procedures for designing, preparing, and using ASTM standard tension test specimens for investigating susceptibility to stress-corrosion cracking. Axially loaded specimens may be stressed quantitatively with equipment for application of either a constant load, constant strain, or with a continuously increasing strain. 1.2 Tension test specimens are adaptable for testing a wide variety of product forms as well as parts joined by welding, riveting, or various other methods. 1.3 The exposure of specimens in a corrosive environment is treated only briefly because other standards are being prepared to deal with this aspect. Meanwhile, the investigator is referred to Practices G35, G36, G37, and G44, and to ASTM Special Technical Publication 425 (1).

  17. Overview and comparative study of GPR international standards and guidelines - COST Action TU1208

    Science.gov (United States)

    Pajewski, Lara; Marciniak, Marian; Benedetto, Andrea; Tosti, Fabio

    2016-04-01

    for Determining the Thickness of Bound Pavement Layers Using Short-Pulse Radar, ASTM International, West Conshohocken, PA, 2010, www.astm.org, DOI: 10.1520/D4748-10. Further ASTM standards exist, not focused on GPR but including useful information (details are not provided here, for brevity reasons). There are no standards in Europe, instead, guiding the GPR use for subsurface prospecting and regulating the numerous applications of this non-destructive technique. The following Radio and Telecommunications Terminal Equipment (R&TTE) directive applies to GPR equipment and allows the placing of a GPR product on the European (EU) market for sale: Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999, on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity. Official Journal of the European Union, L 91, 7.4.1999, open access on ec.europa.eu. This document will be repealed, since 13 June 2016, by the following R&TTE directive: Directive 2014/53/EU of the European Parliament and of the Council of 16 April 2014, on the harmonisation of the laws of the Member States relating to the making available on the market of radio equipment, repealing Directive 1999/5/EC. Official Journal of the European Union, L 153, 22.5.2014, open access on ec.europa. Although conformance to the R&TTE directive allows the placing of a GPR product on the market for sale, it does not give authority for its use. In order to use the equipment, in the majority of EU member countries, a license is required. The license is controlled and issued by the radio administration in each of the member countries. The Electronic Communications Committee (ECC) of the European Conference of Postal and Telecommunications Administrations (CEPT) considers and develops policies on electronic communications activities in European context, taking account of European and international legislations and regulations. There are 48 European countries

  18. Autogenous shrinkage of Ducorit S5R ASTM C 1698-09 test method

    DEFF Research Database (Denmark)

    Damkilde, Lars

    The report deals with experimental measurement of autogenous shrinkage of Ducorit S5R according to the test method ASTM C 1698-09. This test method measures the bulk strain of a sealed cementitious specimen, at constant temperature and not subjected to external forces, from the time of final...

  19. Standardized Cost Structure for the Environmental Industry

    International Nuclear Information System (INIS)

    Skokan, B.; Melamed, D.; Guevara, K.; Mallick, P.; Bierman, G.; Marshall, H.E.

    2006-01-01

    The underlying key to developing successful estimates, tracking project costs, and utilizing historical project cost information is the development of standardized and well-defined hierarchical listing of cost categories. Committees within the U.S. Federal agencies have pioneered efforts toward developing the Environmental Cost Element Structure (ECES), which is key in achieving these goals. The ECES was developed using an iterative process with input from federal agencies and industry. Experts from several disciplines participated including engineers, cost estimators, project/program managers, and contract personnel. The ECES benefits from an intense analytical effort, the knowledge gained from the maturation of the environmental industry, and incorporation of past user's experiences. Building upon this foundation, the E06 committee of the ASTM International has now fully developed and published a standard (ASTM 2150-04) that provides standardized cost categories with complete cost category definitions. This standard affords environmental and nuclear D and D project managers the opportunity to have a well defined hierarchical listing of their estimates and actual costs, readily adapted to performing summations and roll-ups, supported by a multi-level dictionary specifically defining the content of the cost elements as well as the summations. Owing to the dynamic nature of the environmental technologies, efforts need to be made to continue to update this standard by adding new technologies and methods as they are developed and employed in the field. Lastly, the Environmental Cost Element Structure that is embodied in this standard also presents opportunities to develop historical cost databases and comprehensive life cycle cost estimates and standardized cost estimating tools. (authors)

  20. Fractionation and characterization of particles simulating wear of total joint replacement (TJR) following ASTM standards.

    Science.gov (United States)

    Saha, Subrata; Musib, Mrinal

    2011-01-01

    Reactions of bone cells to orthopedic wear debris produced by the articulating motion of total joint replacements (TJRs) are largely responsible for the long-term failure of such replacements. Metal and polyethylene (PE) wear particles isolated from fluids from total joint simulators, as well as particles that are fabricated by other methods, are widely used to study such in vitro cellular response. Prior investigations have revealed that cellular response to wear debris depends on the size, shape, and dose of the particles. Hence, to have a better understanding of the wear-mediated osteolytic process it is important that these particles are well characterized and clinically relevant, both qualitatively, and quantitatively. In this study we have fractionated both ultra-high molecular weight polyethylene (UHMWPE) and Ti particles, into micron (1.0-10.0 μm), submicron (0.2-1.0 μm), and nanoparticle (0.01-0.2 μm) fractions, and characterized them based on the following size-shape descriptors as put forth in ASTM F1877: i) equivalent circle diameter (ECD), ii) aspect ratio (AR), iii) elongation (E), iv) roundness (R), and v) form factor (FF). The mean (± SD) ECDs (in μm) for micron, submicron, and nanoparticles of UHMWPE were 1.652 ± 0.553, 0.270 ± 0.180, and 0.061 ± 0.035, respectively, and for Ti were 1.894 ± 0.667, 0.278 ± 0.180, and 0.055 ± 0.029, respectively. The values for other descriptors were similar (no statistically significant difference). The nanofraction particles were found to be more sphere-like (higher R and FF values, and lower E and AR values) as compared to larger particles. Future experiments will involve use of these well characterized particles for in vitro studies.

  1. 77 FR 73354 - Safety Standard for Hand-Held Infant Carriers

    Science.gov (United States)

    2012-12-10

    .... Edwards, Project Manager, Directorate for Engineering Sciences, U.S. Consumer Product Safety Commission, 5..., allergic reactions and near- choking episodes are the most common injuries reported in the remaining 58... modification of the ASTM standard to address the requirements for flammability, surface chemicals, cords...

  2. Activity and gamma-ray emission standards

    International Nuclear Information System (INIS)

    Debertin, K.

    1983-01-01

    The standards made available by PTB are standards defined with regard to their activity A. If standard and measuring sample do not contain the same nuclide, the comparison with the standard is made via the emission rate R of the photons of a given energy. For this comparison, the value recommended by PTB for PTB standards should be used, as this value in many cases has been derived by emission rate measurements on specimens whose activity has been directly correlated with the activity of the standards released. (orig./DG) [de

  3. SOFG: Standards requirements

    International Nuclear Information System (INIS)

    Gerganov, T.; Grigorov, S.; Kozhukharov, V.; Brashkova, N.

    2005-01-01

    It is well-known that Solid Oxide Fuel Cells will have industrial application in the nearest future. In this context, the problem of SOFC materials and SOFC systems standardization is of high level of priority. In the present study the attention is focused on the methods for physical and chemical characterization of the materials for SOFC components fabrication and about requirements on single SOFC cells tests. The status of the CEN, ISO, ASTM (ANSI, ASSN) and JIS class of standards has been verified. Standards regarding the test methods for physical-chemical characterization of vitreous materials (as sealing SOFC component), ceramic materials (as electrodes and electrolyte components, including alternative materials used) and metallic materials (interconnect components) are subject of overview. It is established that electrical, mechanical, surface and interfacial phenomena, chemical durability and thermal corrosion behaviour are the key areas for standardization of the materials for SOFC components

  4. 78 FR 73965 - Manufactured Home Construction and Safety Standards

    Science.gov (United States)

    2013-12-09

    ...-free number). Persons with hearing or speech impairments may access this number through TTY by calling... Steel, and Seals. U--ASTM D4635 2001 Standard Specification 3280.611(d). for Polyethylene Films Made... reduce burdens and maintain flexibility and freedom of choice for the public. This rule is not a...

  5. Effects of Tempering Temperature and Path on the Microstructural and Mechanical Properties of ASTM Gr.92 Steel

    International Nuclear Information System (INIS)

    Han, C. H.; Baek, J. H.; Kim, S. H.; Lee, C. B.; Kim, Y. K.; Hong, S. I.

    2009-01-01

    SFR (Sodium-Cooled Fast Reactor) is one of the prospective nuclear reactor for the next generation (Gen-IV) systems. The fuel claddings in the SFR are subject to a high fast nuclear irradiation and a high temperature. Fuel technology is a key aspect of an SFR system, with implications for reactor safety, reactor operations, fuel reprocessing technology, and overall system economics. ASTM Gr.92 steel has been considered as the one of the main candidate fuel cladding materials in the design of SFR in that it has higher thermal conductivity as well as dimensional stability under irradiation when compared as austenitic stainless steel. The changes in microstructure and heat-treatment varying M 23 C 6 , MX, M 2 X, and precipitation by ASTM Gr.92 steels to improve high temperature mechanical properties is the attention. According to several researchers, it plays an important role in the mechanical properties of precipitates V, Nb, Cr, C, N as a form of MX and M 2 X precipitates. These fine precipitates formed in the sub- grain by preventing the movement of dislocations in high-temperature mechanical properties will contribute effectively. This study investigated the effects of tempering temperature and heat-treatment path on microstructure and mechanical properties of ASTM Gr.92 steels

  6. A new method to determine J0-integral values (ASTM E 813) without any auxiliary equipment

    International Nuclear Information System (INIS)

    Ullrich, G.; Krompholz, K.

    1987-01-01

    In this contribution the path independent J-integral according to J.R. Rice, respective J.D. Landes and J.A. Begley due to ASTME 813 is calculated by the product J pl = d v J el for 3 point bend type specimen. Here d v is the load point displacement up to the point of the onset of stable crack growth V, which is taken from the load versus load point displacement diagram and J el a value which is equivalent to K 2 /E, where K is the stress intensity factor (ASTME 399) and E is Young's modulus. The advantage of the new procedure is the simplicity of the test arrangement and of the evaluation with the determination of initiation point V without computer or other auxiliary equipment. (orig.) [de

  7. Biocompatibility of metal injection molded versus wrought ASTM F562 (MP35N) and ASTM F1537 (CCM) cobalt alloys.

    Science.gov (United States)

    Chen, Hao; Sago, Alan; West, Shari; Farina, Jeff; Eckert, John; Broadley, Mark

    2011-01-01

    We present a comparative analysis between biocompatibility test results of wrought and Metal Injection Molded (MIM) ASTM F562-02 UNS R30035 (MP35N) and F1537 UNS R31538 (CCM) alloy samples that have undergone the same generic orthopedic implant's mechanical, chemical surface pre-treatment, and a designed pre-testing sample preparation method. Because the biocompatibility properties resulting from this new MIM cobalt alloy process are not well understood, we conducted tests to evaluate cytotoxicity (in vitro), hemolysis (in vitro), toxicity effects (in vivo), tissue irritation level (in vivo), and pyrogenicity count (in vitro) on such samples. We show that our developed MIM MP35N and CCM materials and treatment processes are biocompatible, and that both the MIM and wrought samples, although somewhat different in microstructure and surface, do not show significant differences in biocompatibility.

  8. 75 FR 39871 - Manufactured Home Construction and Safety Standards

    Science.gov (United States)

    2010-07-13

    ... (ANSI A208.2-2004) and would require no change in existing technology for either product to achieve the... certificates required by this section would be amended to refer to the 1997 edition of the ASHRAE Handbook of... for Bathing Facilities. U--ASTM C564 1997 Standard Specification for Rubber 3280.611(d) Gaskets for...

  9. Application of MCDM based hybrid optimization tool during turning of ASTM A588

    Directory of Open Access Journals (Sweden)

    Himadri Majumder

    2017-07-01

    Full Text Available Multi-criteria decision making approach is one of the most troublesome tools for solving the tangled optimization problems in the machining area due to its capability of solving the complex optimization problems in the production process. Turning is widely used in the manufacturing processes as it offers enormous advantages like good quality product, customer satisfaction, economical and relatively easy to apply. A contemporary approach, MOORA coupled with PCA, was used to ascertain an optimal combination of input parameters (spindle speed, depth of cut and feed rate for the given output parameters (power consumption, average surface roughness and frequency of tool vibration using L27 orthogonal array for turning on ASTM A588 mild steel. Comparison between MOORA-PCA and TOPSIS-PCA shows the effectiveness of MOORA over TOPSIS method. The optimum parameter combination for multi-performance characteristics has been established for ASTM A588 mild steel are spindle speed 160 rpm, depth of cut 0.1 mm and feed rate 0.08 mm/rev. Therefore, this study focuses on the application of the hybrid MCDM approach as a vital selection making tool to deal with multi objective optimization problems.

  10. An investigation of force components in orthogonal cutting of medical grade cobalt-chromium alloy (ASTM F1537).

    Science.gov (United States)

    Baron, Szymon; Ahearne, Eamonn

    2017-04-01

    An ageing population, increased physical activity and obesity are identified as lifestyle changes that are contributing to the ongoing growth in the use of in-vivo prosthetics for total hip and knee arthroplasty. Cobalt-chromium-molybdenum (Co-Cr-Mo) alloys, due to their mechanical properties and excellent biocompatibility, qualify as a class of materials that meet the stringent functional requirements of these devices. To cost effectively assure the required dimensional and geometric tolerances, manufacturers rely on high-precision machining. However, a comprehensive literature review has shown that there has been limited research into the fundamental mechanisms in mechanical cutting of these alloys. This article reports on the determination of the basic cutting-force coefficients in orthogonal cutting of medical grade Co-Cr-Mo alloy ASTM F1537 over an extended range of cutting speeds ([Formula: see text]) and levels of undeformed chip thickness ([Formula: see text]). A detailed characterisation of the segmented chip morphology over this range is also reported, allowing for an estimation of the shear plane angle and, overall, providing a basis for macro-mechanic modelling of more complex cutting processes. The results are compared with a baseline medical grade titanium alloy, Ti-6Al-4V ASTM F136, and it is shown that the tangential and thrust-force components generated were, respectively, ≈35% and ≈84% higher, depending primarily on undeformed chip thickness but with some influence of the cutting speed.

  11. MÉTODOS PARA CARACTERIZAR COMBUSTIBLES LÍQUIDOS Y GASEOSOS OBTENIDOS DE LLANTAS EN DESUSO A TRAVÉS DE LAS NORMAS ASTM.

    Directory of Open Access Journals (Sweden)

    JAIME ALEJANDRO OSPINA

    2011-12-01

    Full Text Available Este artículo muestra la importancia de la caracterización de la energía de combustibles líquidos y gaseosos obtenidos del conocido tratamiento térmico de pirolisis a través de un microondas. La caracterización de estos combustibles tomará en cuenta los estándares técnicos tales como ASTM D3452 – 93 para la cromatografía de gases (GC, ASTM D2549 para cromatografía de gas/ espectrometría de masa (GC/MS y ASTM D6370 -99 para termogravimetría en el análisis de la composición de llantas.También muestra que estos combustibles y gases de pirolisis tiene una alta valor calorífico de 42 MJ / Kg y un contenido de azufre entre 0.8 y 1.65 Wt%, dependiendo en el tipo de llanta y las condiciones del proceso.

  12. Model of ASTM Flammability Test in Microgravity: Iron Rods

    Science.gov (United States)

    Steinberg, Theodore A; Stoltzfus, Joel M.; Fries, Joseph (Technical Monitor)

    2000-01-01

    There is extensive qualitative results from burning metallic materials in a NASA/ASTM flammability test system in normal gravity. However, this data was shown to be inconclusive for applications involving oxygen-enriched atmospheres under microgravity conditions by conducting tests using the 2.2-second Lewis Research Center (LeRC) Drop Tower. Data from neither type of test has been reduced to fundamental kinetic and dynamic systems parameters. This paper reports the initial model analysis for burning iron rods under microgravity conditions using data obtained at the LERC tower and modeling the burning system after ignition. Under the conditions of the test the burning mass regresses up the rod to be detached upon deceleration at the end of the drop. The model describes the burning system as a semi-batch, well-mixed reactor with product accumulation only. This model is consistent with the 2.0-second duration of the test. Transient temperature and pressure measurements are made on the chamber volume. The rod solid-liquid interface melting rate is obtained from film records. The model consists of a set of 17 non-linear, first-order differential equations which are solved using MATLAB. This analysis confirms that a first-order rate, in oxygen concentration, is consistent for the iron-oxygen kinetic reaction. An apparent activation energy of 246.8 kJ/mol is consistent for this model.

  13. Comparative Study of API 5L X60 and ASTM 572 Gr50 Steel Exposed to Crude Oil and Seawater

    Directory of Open Access Journals (Sweden)

    Marcy Viviana Chiquillo Márquez

    2018-04-01

    Full Text Available In the petroleum industry, the biphasic conditions in storage and separation tanks allow that the material to remain exposed to two different environments, causing its deterioration. In this article, an evaluation is made of the corrosive behavior and Vickers microhardness (HV of two high strength low alloy (HSLA steels and how their surfaces are characterized. The ASTM 572 Gr50 steel showed a lower corrosion rate in all systems after being immersed for 720 and 1440 hours. Characterizing the surface by means of Scanning Electron Microscopy (SEM showed uniform and localized corrosion for the both steels, and revealed that the ASTM 572 Gr50 steel shows pitting corrosion in crude oil systems. The electrochemical results revealed that the corrosion potential of API X60 steel was more negative; however the ASTM 572 Gr50 steel had a higher current density and a lower polarization resistance when immersed in an oil/seawater mixture. It also observed that, after being immersed in the corrosive fluids, the microstructures of the steels were not modified and variations in their microhardness (HV were minute.

  14. Standard Practice for Dosimetry of Proton Beams for use in Radiation Effects Testing of Electronics

    Energy Technology Data Exchange (ETDEWEB)

    McMahan, Margaret A.; Blackmore, Ewart; Cascio, Ethan W.; Castaneda, Carlos; von Przewoski, Barbara; Eisen, Harvey

    2008-07-25

    Representatives of facilities that routinely deliver protons for radiation effect testing are collaborating to establish a set of standard best practices for proton dosimetry. These best practices will be submitted to the ASTM International for adoption.

  15. Standard Practice for Dosimetry of Proton Beams for use in Radiation Effects Testing of Electronics

    International Nuclear Information System (INIS)

    McMahan, Margaret A.; Blackmore, Ewart; Cascio, Ethan W.; Castaneda, Carlos; von Przewoski, Barbara; Eisen, Harvey

    2008-01-01

    Representatives of facilities that routinely deliver protons for radiation effect testing are collaborating to establish a set of standard best practices for proton dosimetry. These best practices will be submitted to the ASTM International for adoption

  16. 77 FR 70390 - Lifesaving Equipment: Production Testing and Harmonization With International Standards

    Science.gov (United States)

    2012-11-26

    ... components within the system to be made of corrosion-resistant materials without the need for galvanizing... resistant in the marine environment without the need for coatings or galvanizing,'' the current ASTM.... This standard would no longer be appropriate because these steels require coatings or galvanizing to be...

  17. A standardized evaluation of artifacts from metallic compounds during fast MR imaging

    DEFF Research Database (Denmark)

    Murakami, Shumei; Verdonschot, Rinus G; Kataoka, Miyoshi

    2016-01-01

    according to the ASTM-F2119 standard and artifact volumes were assessed using OsiriX MD software Results: Tukey-Kramer post-hoc tests were used for statistical comparisons. For most materials, scanning sequences eliciting artifact volumes in the following (ascending) order FSE-T1/FSE-T2

  18. 76 FR 55056 - Toy Safety Standard: Strategic Outreach and Education Plan

    Science.gov (United States)

    2011-09-06

    ... to test and certify to the toy safety standard. We plan to use traditional and social media to... testing and certification requirements for children's toys and toy chests and their compliance with ASTM... manufacturers of children's toys must ensure that covered toys are tested for compliance with the toy safety...

  19. Whole glove permeation of cyclohexanol through disposable nitrile gloves on a dextrous robot hand and comparison with the modified closed-loop ASTM F739 method 1. No fist clenching.

    Science.gov (United States)

    Mathews, Airek R; Que Hee, Shane S

    2017-04-01

    The aim was to develop a whole glove permeation method for cyclohexanol to generate permeation parameter data for a non-moving dextrous robot hand (normalized breakthrough time t b , standardized breakthrough time t s , steady state permeation rate P s , and diffusion coefficient D). Four types of disposable powderless, unsupported, and unlined nitrile gloves from the same producer were investigated: Safeskin Blue and Kimtech Science Blue, Purple, and Sterling. The whole glove method developed involved a peristaltic pump for water circulation through chemically resistant Viton tubing to continually wash the inner surface of the test glove via holes in the tubing, a dextrous robot hand operated by a microprocessor, a chemically protective nitrile glove to protect the robot hand, an incubator to maintain 35°C temperature, and a hot plate to maintain 35°C at the sampling point of the circulating water. Aliquots of 1.0 mL were sampled at regular time intervals for the first 60 min followed by removal of 0.5 mL aliquots every hour to 8 hr. Quantification was by the internal standard method after gas chromatography-selective ion electron impact mass spectrometry using a non-polar capillary column. The individual glove values of t b and t s differed for the ASTM closed loop method except for Safeskin Blue, but did not for the whole glove method. Most of the kinetic parameters agreed within an order of magnitude for the two techniques. The order of most protective to least protective glove was Blue and Safeskin, then Purple followed by Sterling for the whole gloves. The analogous order for the modified F739 ASTM closed loop method was: Safeskin, Blue, Purple, and Sterling, almost the same as for the whole glove. The Sterling glove was "not recommended" from the modified ASTM data, and was "poor" from the whole glove data.

  20. 77 FR 56809 - Certain Small Diameter Seamless Carbon and Alloy Steel Standard, Line, and Pressure Pipe From...

    Science.gov (United States)

    2012-09-14

    ... stress levels. Alloy pipes made to ASTM standard A-335 must be used if temperatures and stress levels... not used in standard, line or pressure applications. In addition, finished and unfinished oil country... antidumping duty order from the same country. If not covered by such an OCTG order, finished and unfinished...

  1. Nondestructive testing standards and the ASME code

    International Nuclear Information System (INIS)

    Spanner, J.C.

    1991-04-01

    Nondestructive testing (NDT) requirements and standards are an important part of the ASME Boiler and Pressure Vessel Code. In this paper, the evolution of these requirements and standards is reviewed in the context of the unique technical and legal stature of the ASME Code. The coherent and consistent manner by which the ASME Code rules are organized is described, and the interrelationship between the various ASME Code sections, the piping codes, and the ASTM Standards is discussed. Significant changes occurred in ASME Sections 5 and 11 during the 1980s, and these are highlighted along with projections and comments regarding future trends and changes in these important documents. 4 refs., 8 tabs

  2. Reactor pressure vessel steels ASTM A533B and A508 Cl.2

    International Nuclear Information System (INIS)

    Pelli, R.; Kemppainen, M.; Toerroenen, K.

    1979-11-01

    This report presents the tensile test results of steels ASTM A533B and A508 Cl.2 obtained in connection with a programme initiated to gather and create information needed for the assessment of the structural integrity of the reactor pressure vessels. The tensile properties were studied between -196 and 300 degC varying austenitizing and tempering temperatures and having two different carbon contents for the heats of A533B. (author)

  3. Recommendations for Autonomous Industrial Vehicle Performance Standards

    OpenAIRE

    Bostelman , Roger

    2016-01-01

    International audience; A workshop was held at the IEEE International Conference on Robotics and Automation, called: “Autonomous Industrial Vehicles: From the Laboratory to the Factory Floor”. Nine research papers were presented followed by a discussion session summarized in this paper. The workshop findings are intended to be useful for developing standards within the ASTM F45 Committee for Driverless Automatic Industrial Vehicles. This paper provides feedback from the discussion listing the...

  4. Ensaios MSCR segundo as normas ASTM D7405-10a e AASHTO T350-14: um estudo de caso envolvendo ligantes asfálticos modificados

    Directory of Open Access Journals (Sweden)

    Matheus David Inocente Domingos

    2016-12-01

    especially the AC+rubber and the AC+rubber+PPA. The AC+PPA showed low stress sensitivity and the best results for the parameters R and Jnr at 3,200 Pa either in the ASTM or the AASHTO protocols, which justifies its choice as the best formulation. The data from the modified asphalt binders suggest that the change from the ASTM protocol to the AASHTO one is recommended.

  5. Standardized physics-dosimetry for US pressure vessel cavity surveillance programs

    International Nuclear Information System (INIS)

    Ruddy, F.H.; McElroy, W.N.; Lippincott, E.P.

    1984-01-01

    This paper summarizes the applications of ASTM standard methods, guides and practices to define the selection and deployment of recommended dosimetry sets, the selection of dosimetry capsules and thermal neutron shields, the placement of dosimetry, the methods of measurement of dosimetry sensor reaction products, data analysis procedures, and uncertainty evaluation procedures. It also describes the validation of these standards both by in-reactor testing of advanced PV cavity surveillance physics-dosimetry and by data development. The use of these standards to guide selection and development of advanced dosimetry sets for commercial reactors is also summarized. (Auth.)

  6. Active Faraday optical frequency standard.

    Science.gov (United States)

    Zhuang, Wei; Chen, Jingbiao

    2014-11-01

    We propose the mechanism of an active Faraday optical clock, and experimentally demonstrate an active Faraday optical frequency standard based on narrow bandwidth Faraday atomic filter by the method of velocity-selective optical pumping of cesium vapor. The center frequency of the active Faraday optical frequency standard is determined by the cesium 6 (2)S(1/2) F=4 to 6 (2)P(3/2) F'=4 and 5 crossover transition line. The optical heterodyne beat between two similar independent setups shows that the frequency linewidth reaches 281(23) Hz, which is 1.9×10(4) times smaller than the natural linewidth of the cesium 852-nm transition line. The maximum emitted light power reaches 75 μW. The active Faraday optical frequency standard reported here has advantages of narrow linewidth and reduced cavity pulling, which can readily be extended to other atomic transition lines of alkali and alkaline-earth metal atoms trapped in optical lattices at magic wavelengths, making it useful for new generation of optical atomic clocks.

  7. Defense Standardization Program Journal. April/June 2011

    Science.gov (United States)

    2011-06-01

    years, the seven winners have played an integral part in keeping our men and women in uniform sate and in providing them the tools they need to get...supporting our men and women in uniform, helping to multiply capability through interoperability, and saving money tor the taxpayer. 1 hope that reading...committee chair of ASTM B687, "Standard Specifi- cation for Brass, Copper, and Chromium-Plated Pipe Nipples " (FSC 4730), to incor- porate eight additional

  8. Brain activity is related to individual differences in the number of items stored in auditory short-term memory for pitch: evidence from magnetoencephalography.

    Science.gov (United States)

    Grimault, Stephan; Nolden, Sophie; Lefebvre, Christine; Vachon, François; Hyde, Krista; Peretz, Isabelle; Zatorre, Robert; Robitaille, Nicolas; Jolicoeur, Pierre

    2014-07-01

    We used magnetoencephalography (MEG) to examine brain activity related to the maintenance of non-verbal pitch information in auditory short-term memory (ASTM). We focused on brain activity that increased with the number of items effectively held in memory by the participants during the retention interval of an auditory memory task. We used very simple acoustic materials (i.e., pure tones that varied in pitch) that minimized activation from non-ASTM related systems. MEG revealed neural activity in frontal, temporal, and parietal cortices that increased with a greater number of items effectively held in memory by the participants during the maintenance of pitch representations in ASTM. The present results reinforce the functional role of frontal and temporal cortices in the retention of pitch information in ASTM. This is the first MEG study to provide both fine spatial localization and temporal resolution on the neural mechanisms of non-verbal ASTM for pitch in relation to individual differences in the capacity of ASTM. This research contributes to a comprehensive understanding of the mechanisms mediating the representation and maintenance of basic non-verbal auditory features in the human brain. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Activities of Radiation Standard Section

    International Nuclear Information System (INIS)

    Kannan, A.; Rao, P.S.; Sachadev, R.N.; Shaha, V.V.; Sharma, D.; Srivastava, P.K.

    1992-01-01

    A brief account of the various facilities and services provided by the Radiation Standards Section (RSS) of the Bhabha Atomic Research Centre, Bombay is given. RSS maintains the primary and secondary standards of various parameters of radiation measurements. It ensures accurate radiological measurements as per international requirements, through periodic international intercomparisons of national standards. It also provides calibration services to various users of radiation sources and instruments. The activities of RSS are described under the headings: (1) Radiological Metrology Standards, (2) Radionuclide Standards, Neutron Metrology, (4) Instruments Calibration, (5) Non-ionizing Radiations, and (6) Instrumentation. (author). figs., tabs

  10. A proposed standard round compact specimen for plane strain fracture toughness testing

    Science.gov (United States)

    Underwood, J. H.; Newman, J. C., Jr.; Seeley, R. R.

    1980-01-01

    A round, disk-shaped specimen is proposed as a standard test specimen for addition to ASTM Test for Plane-Strain Fracture Toughness of Metallic Materials (E 399-78A). The specimen is diametrically cracked, and loaded in the same way as the existing standard compact specimen. Tests and analyses were performed to verify that the proposed round compact specimen and associated stress intensity factor K solution are appropriate for a standard plane strain fracture toughness test. The use of the round compact specimen for other fracture tests is described.

  11. COMPETITION BEETWEN DYNAMIC RECUPERATION AND RECRYSTALLIZATION OF ASTM F 138 AUSTENITIC STAINLESS STEEL UTILIZED IN MEDICAL DEVICES

    Directory of Open Access Journals (Sweden)

    Fabio Henrique Casarini Geronimo

    2013-06-01

    Full Text Available ASTM F 138 austenitic stainless steel has being used in the manufacture of orthopedical devices by hot forging. In this work, the flow stress curves are determined by hot torsion tests in a wide range of temperatures and strain rates. With the observed microestrutural evolution by optical microscopy in different hot forming conditions in addiction with EBSD (Electron Backscatter Diffraction techniques it is possible to obtained the recrystallized volume fraction and the misorientation angles of the samples. Due to the intermediate level of stacking fault energy of this material, during the dynamic softening occurs a competition between recrystallization and recovery. The aim of this work is to identify the softening mechanisms in this stainless steel, as well as in which hot work conditions they become more active.

  12. 76 FR 39852 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe (Over 41/2

    Science.gov (United States)

    2011-07-07

    ..., or equivalent, to the American Society for Testing and Materials (``ASTM'') A-53, ASTM A-106, ASTM A-333, ASTM A- 334, ASTM A-589, ASTM A-795, and the American Petroleum Institute (``API'') 5L... American Society of Mechanical Engineers (``ASME'') code stress levels. Alloy pipes made to ASTM A-335...

  13. 77 FR 13079 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe (Over 41/2

    Science.gov (United States)

    2012-03-05

    ... produced, or equivalent, to the American Society for Testing and Materials (``ASTM'') A-53, ASTM A-106, ASTM A-333, ASTM A- 334, ASTM A-589, ASTM A-795, and the American Petroleum Institute (``API'') 5L... American Society of Mechanical Engineers (``ASME'') code stress levels. Alloy pipes made to ASTM A-335...

  14. Simplification and transformation of ASTM F1292 measurement procedure for fall accident injury criteria.

    Science.gov (United States)

    Kato, Maki; Shimodaira, Yoshie; Sato, Takeshi; Iida, Hiromi

    2014-01-01

    Protecting children from injuries caused by fall accidents from playground equipment is important. Therefore, measures toward minimizing the risk of fall accident injuries are required. The risk of injury can be evaluated using ASTM F1292. In this test, G-max and the HIC are used to estimate the risk of injury. However, the measurement procedure is too complicated for application to a large number of installed equipment. F1292 requires simplified by reducing the number of phases, even with a small risk of loss in accuracy. With this in mind, this study proposes a shortened measurement procedure and a transformation equation to estimate the risk as same as F1292. As the result of experiments, it was revealed that G-max and the HIC values for both procedures linearly increase with drop height. The differences in outcomes between the regression equations of the standardized procedure and those of the shortened procedure can be used as a correction value. They can be added to the value measured by the shortened procedure. This suggests that the combination of the shortened procedure and transformation equation would be equivalent to F1292, with the advantage of being more easily and efficiently applied to the evaluation of installed playground equipment.

  15. State of the reactor vessel surveillance programs in Korea and foreign countries

    International Nuclear Information System (INIS)

    Kim, Jeong Kyu; Hwang, Jong Keun; Park, Keon Woo; Kim, Bum Sik; Jeong, Kyung Hoon

    1996-06-01

    ASTM standards are dominating all over the world in the field of the reactor vessel surveillance program. They are mainly used directly or that the national standards in use correspond quite well with ASTM. According to, however, increasing concerns about the protection of environment and safety of nuclear plant, various approaches to establish and reinforce the national standards are made actively in Europe. In addition, some methods to share the nuclear data by integrating the existing test, analysis procedures and units system are considered. For nuclear plants in Korea, MOST Notice No. 92-20 should be applied for all PWRs after UCN units 3 and 4 since it was promulgated at Dec. 1992. The notice almost reflects the contents of ASTM E 185. But, the notice has much to be desired to provide the technical back-ground for reactor vessel surveillance program because it is not a standard such as ASTM or ASME code but regulation such as CFR or RG. Several Korean Standards are also used in limited area of the surveillance program. Therefore, practical requirements and rules for surveillance program are in accordance with the ASTM and CFR. In this report, the state of application of the standards to the surveillance program in Korea and Europe are reviewed and their national standards re compared with US standards or regulations. Current level and the future prospect of surveillance technology for PWR vessel are discussed at this point of view. 15 tabs., 12 figs., 38 refs. (Author)

  16. Repeatability and Reproducibility of Compression Strength Measurements Conducted According to ASTM E9

    Science.gov (United States)

    Luecke, William E.; Ma, Li; Graham, Stephen M.; Adler, Matthew A.

    2010-01-01

    Ten commercial laboratories participated in an interlaboratory study to establish the repeatability and reproducibility of compression strength tests conducted according to ASTM International Standard Test Method E9. The test employed a cylindrical aluminum AA2024-T351 test specimen. Participants measured elastic modulus and 0.2 % offset yield strength, YS(0.2 % offset), using an extensometer attached to the specimen. The repeatability and reproducibility of the yield strength measurement, expressed as coefficient of variations were cv(sub r)= 0.011 and cv(sub R)= 0.020 The reproducibility of the test across the laboratories was among the best that has been reported for uniaxial tests. The reported data indicated that using diametrically opposed extensometers, instead of a single extensometer doubled the precision of the test method. Laboratories that did not lubricate the ends of the specimen measured yield stresses and elastic moduli that were smaller than those measured in laboratories that lubricated the specimen ends. A finite element analysis of the test specimen deformation for frictionless and perfect friction could not explain the discrepancy, however. The modulus measured from stress-strain data were reanalyzed using a technique that finds the optimal fit range, and applies several quality checks to the data. The error in modulus measurements from stress-strain curves generally increased as the fit range decreased to less than 40 % of the stress range.

  17. Anodic Protection performance of Steels ASTM A 516-60 And JIS G 3131 SPHC In Concentrated Sulfuric Acid

    International Nuclear Information System (INIS)

    Harsisto; Ginting, Immanuel; Eddy, D.C

    2001-01-01

    One of the methods to protect a carbon steel material from corrosion attack of sulfuric acid environment is with anodic protection. This research was intended to investigate the effect of anodic protection quickened with potential polarization, The material under investigation were ASTM A 516 and JIS G 3131-SPHC in highly concentrated H 2 SO 4 solution. The results showed that potential that was effective for anodic protection in ASTM A 516-60 were at 236-436 mV for 75%, 276-476 mV for 80%, 264-514 mV for 85%,285-485 mV for 90%, and 231-431 mV for 97% H 2 SO 4 so that in JlS G 3131-SPHC were at 303 -503 mV for 75%, 290-490 mV for 80%, 269- 516 mV for 85%, 264-514 mV for 90%, and 287 -487 mV for 97% H 2 SO 4

  18. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  19. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  20. Effect of C content on the mechanical properties of solution treated as-cast ASTM F-75 alloys.

    Science.gov (United States)

    Herrera, M; Espinoza, A; Méndez, J; Castro, M; López, J; Rendón, J

    2005-07-01

    The mechanical properties of solution treated ASTM F-75 alloys with various carbon contents have been studied. Alloys cast under the same conditions were subjected to solution treatment for several periods and then their tensile properties were evaluated. In the as-cast conditions, the alloys exhibited higher strength values with increasing carbon content whereas their ductility was not significantly affected. For the solution treated alloys, the variation of the strength was characterized by a progressive increase for short treatment times until a maximum value was achieved, which was followed by a diminution in this property for longer treatment times. This behavior was more accentuated for the case of the alloys with medium carbon contents, which also exhibited the highest values of strength. Furthermore, the alloy's ductility was enhanced progressively with increasing solution treatment time. This improvement in ductility was significantly higher for the medium carbon alloys compared with the rest of the studied alloys. Thus, high and low carbon contents in solution treated ASTM F-75 alloys did not produced sufficiently high tensile properties.

  1. 40 CFR 92.5 - Reference materials.

    Science.gov (United States)

    2010-07-01

    ..., Standard Test Method for Distillation of Petroleum Products § 92.113 ASTM D 93-94, Standard Test Methods... API Gravity of Crude Petroleum and Petroleum Products (Hydrometer Method) § 92.113 ASTM D 445-94... Viscosity) § 92.113 ASTM D 613-95, Standard Test Method for Cetane Number of Diesel Fuel Oil § 92.113 ASTM D...

  2. 76 FR 62762 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line and Pressure Pipe From Japan...

    Science.gov (United States)

    2011-10-11

    ... Fahrenheit, at various American Society of Mechanical Engineers (``ASME'') code stress levels. Alloy pipes made to ASTM A-335 standard must be used if temperatures and stress levels exceed those allowed for..., or pressure pipe applications. B. Finished and unfinished oil country tubular goods (``OCTG''), if...

  3. Corrosion resistant properties and weldabilities of ASTM Grade 12 titanium alloy

    International Nuclear Information System (INIS)

    Tsumori, Yoshikatsu; Itoh, Hideo

    1988-01-01

    Plates, sheets, bars, wires and thinner seam-welded tubings were manufactured from large-scaled ingot of ASTM Grade 12 alloy (Ti-0.8Ni-0.3Mo). The processability of G-12 alloy has proved almost similar to that of conventional commercially pure titanium grades. It has been clarified that the G-12 alloy showed several advantageous features: Chlorides-Crevice corrosion resistance of the alloy was almost equals to G-7 and Pd0/TiO 2 coated titanium, and the maximum allowable stress was able to be designed higher than that of commercially pure titanium. This alloy has been in applications also offers where such environments as seawater, brines and moist chlorine, various oil refinery and chemical industries, and others. (author)

  4. Photon and proton activation analysis of iron and steel standards using the internal standard method coupled with the standard addition method

    International Nuclear Information System (INIS)

    Masumoto, K.; Hara, M.; Hasegawa, D.; Iino, E.; Yagi, M.

    1997-01-01

    The internal standard method coupled with the standard addition method has been applied to photon activation analysis and proton activation analysis of minor elements and trace impurities in various types of iron and steel samples issued by the Iron and Steel Institute of Japan (ISIJ). Samples and standard addition samples were once dissolved to mix homogeneously, an internal standard and elements to be determined and solidified as a silica-gel to make a similar matrix composition and geometry. Cerium and yttrium were used as an internal standard in photon and proton activation, respectively. In photon activation, 20 MeV electron beam was used for bremsstrahlung irradiation to reduce matrix activity and nuclear interference reactions, and the results were compared with those of 30 MeV irradiation. In proton activation, iron was removed by the MIBK extraction method after dissolving samples to reduce the radioactivity of 56 Co from iron via 56 Fe(p, n) 56 Co reaction. The results of proton and photon activation analysis were in good agreement with the standard values of ISIJ. (author)

  5. 75 FR 38781 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe From Japan...

    Science.gov (United States)

    2010-07-06

    ... Fahrenheit, at various American Society of Mechanical Engineers (``ASME'') code stress levels. Alloy pipes made to ASTM A-335 standard must be used if temperatures and stress levels exceed those allowed for.... B. Finished and unfinished oil country tubular goods (``OCTG''), if covered by the scope of another...

  6. Analysis of standard fracture toughness test based on digital image correlation data

    Czech Academy of Sciences Publication Activity Database

    Jandejsek, Ivan; Gajdoš, Lubomír; Šperl, Martin; Vavřík, Daniel

    2017-01-01

    Roč. 182, September (2017), s. 607-620 ISSN 0013-7944 R&D Projects: GA ČR(CZ) GA15-07210S; GA TA ČR(CZ) TE02000162 Keywords : DIC * full-field measurement * J-integral * CTOD * ASTM standard Subject RIV: JL - Materials Fatigue, Friction Mechanics OBOR OECD: Audio engineering, reliability analysis Impact factor: 2.151, year: 2016 http://www.sciencedirect.com/science/article/pii/S0013794417305799

  7. Assessment of wrought ASTM F1058 cobalt alloy properties for permanent surgical implants.

    Science.gov (United States)

    Clerc, C O; Jedwab, M R; Mayer, D W; Thompson, P J; Stinson, J S

    1997-01-01

    The behavior of the ASTM F1058 wrought cobalt-chromium-nickel-molybdenum-iron alloy (commonly referred to as Elgiloy or Phynox) is evaluated in terms of mechanical properties, magnetic resonance imaging, corrosion resistance, and biocompatibility. The data found in the literature, the experimental corrosion and biocompatibility results presented in this article, and its long track record as an implant material demonstrate that the cobalt superalloy is an appropriate material for permanent surgical implants that require high yield strength and fatigue resistance combined with high elastic modulus, and that it can be safely imaged with magnetic resonance.

  8. Glove powder's carrying capacity for latex protein: analysis using the ASTM ELISA test.

    Science.gov (United States)

    Beezhold, D; Horton, K; Hickey, V; Daddona, J; Kostyal, D

    2003-01-01

    Glove donning powders carry latex proteins and disperse them into the workplace environment. We have used the ASTM D6499 ELISA to quantify the amount of latex antigen bound to and carried by glove powders. We could differentiate between a small amount of protein actually bound to the powders and a larger amount carried by the powder. Enhanced binding of a major allergen, Hev b 5, to the starch powders was demonstrated by Western blot. The D6499 ELISA is able to measure total latex antigen, soluble and powder bound, simultaneously without the need to centrifuge the samples.

  9. Standard Practice for Analysis and Interpretation of Light-Water Reactor Surveillance Results, E706(IA)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2001-01-01

    1.1 This practice covers the methodology, summarized in Annex A1, to be used in the analysis and interpretation of neutron exposure data obtained from LWR pressure vessel surveillance programs; and, based on the results of that analysis, establishes a formalism to be used to evaluate present and future condition of the pressure vessel and its support structures (1-70). 1.2 This practice relies on, and ties together, the application of several supporting ASTM standard practices, guides, and methods (see Master Matrix E 706) (1, 5, 13, 48, 49). In order to make this practice at least partially self-contained, a moderate amount of discussion is provided in areas relating to ASTM and other documents. Support subject areas that are discussed include reactor physics calculations, dosimeter selection and analysis, and exposure units. Note 1—(Figure 1 is deleted in the latest update. The user is refered to Master Matrix E 706 for the latest figure of the standards interconnectivity). 1.3 This practice is restri...

  10. Effects of Spray Mixtures on Droplet Size Under Aerial Application Conditions and Implications on Drift

    Science.gov (United States)

    2010-01-01

    Liquid Drop Size Characteristics in a Spray Using Optical Nonimaging Light‐Scattering Instruments (ASTM Standards, 2003). The most common term used to...using optical nonimaging light‐scattering instruments. West Conshohocken, Pa.: ASTM Intl. ASTM Standards. 2004. E 1620. Standard terminology relating

  11. Determination of ASTM 1016 structural welded joints fracture toughness through J integral

    International Nuclear Information System (INIS)

    Martins, Geraldo de Paula; Villela, Jefferson Jose; Terra, Jose Lucio; Rabello, Emerson Giovani; Martins, Geraldo Antonio Scoralick; Carneiro, Jose Rubens Goncalves

    2009-01-01

    Fracture toughness is an important parameter for studies of materials behavior in nuclear and conventional industry. Crack propagation resistance is, in general, evaluate using one of the fracture mechanics parameters K IC , for the case of the materials that exhibits a linear elastic behavior, the CTOD (crack tip opening displacement) and J IC , the critical value of J Integral, for the case of materials with elastic-plastic behavior. On this work the fracture mechanics parameters of the ASTM 1016 structural steel welded joints were obtained, using the J Integral. Charpy V tests at several temperatures were also obtained, with the purpose to obtain the curves of ductile-brittle of the regions of the welded joints: Base Metal, (MB), and Melted Zone (MZ). The joints were welded by Gas Metal Arc Welding (GMAW) with V bevel for evaluation the MZ toughness properties. The tests were accomplished at temperatures varying from -100 deg C to 100 deg C using the technical of compliance variation for J IC determination, the critical value that defines the initial stable crack growth, that applies to brittle and ductile materials. The J Integral alternative specimens has square cross section 10mmX10mm, according ASTM E 1820, with notch localized respectively at the BM and MZ. After the tests, the specimens fractured were analyzed in a scanning microscopic electronic (SME) for verification of the fracture surface. The fractography of the specimens at elevated temperatures presented dimples at the region of stable crack growth, characteristic of ductile fracture. The results of J Integral and Charpy V presented a good correlation between these two parameters. From these correlations it can be concluded that in some applications, the use Charpy V energy to infer fracture toughness can be substitute the Integral J tests. (author)

  12. Soils Project Risk-Based Corrective Action Evaluation Process with ROTC 1 and ROTC 2, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    Matthews, Patrick; Sloop, Christina

    2012-04-01

    This document formally defines and clarifies the NDEP-approved process the NNSA/NSO Soils Activity uses to fulfill the requirements of the FFACO and state regulations. This process is used to establish FALs in accordance with the risk-based corrective action (RBCA) process stipulated in Chapter 445 of the Nevada Administrative Code (NAC) as described in the ASTM International (ASTM) Method E1739-95 (NAC, 2008; ASTM, 1995). It is designed to provide a set of consistent standards for chemical and radiological corrective actions.

  13. Application of ASTM E-1559 Apparatus to Study H2O Desorption

    Science.gov (United States)

    Woronowicz, Michael; Perry, Radford, III; Meadows, George A.

    2015-01-01

    The NASA James Webb Space Telescope project identified a need to measure water vapor desorption from cryogenic surfaces in order to validate predictions of spacecraft design performance. A review of available scientific literature indicated no such measurements had been reported below 131 K. Contamination control personnel at NASA Goddard Space Flight Center recognized the possibility they readily possessed the means to collect these measurements at lower temperatures using an existing apparatus commonly employed for making outgassing observations. This presentation will relate how the ASTM E-1559 Molekit apparatus was used without physical modification to measure water vapor sublimation down to 120 K and compare this data to existing equilibrium vapor pressure models.

  14. DOE Technical Standards List. Directory of DOE and contractor personnel involved in non-government standards activities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-06-01

    This is a periodic report on the level of agency participation in non-Government standards activities. This technical standards list is intended to assist US Department of Energy (DOE) management and other personnel involved in the DOE technical Standards Program by identifying those participating individuals. The body of this document contains a listing of DOE employees and DOE contractors who have submitted a Record of Non-Government Standards Activity. Additional names were added from rosters supplied by non-Government standards bodies. Appendices to this document are provided to list the information by parent employment organization, by non-Government standards activity, and by the proper names of the non-Government standards organizations and committees.

  15. Dosimetry-adjusted reactor physics parameters for pressure vessel neutron exposure assessment

    International Nuclear Information System (INIS)

    McElroy, W.N.; Kellogg, L.S.

    1988-01-01

    The ASTM E706 master matrix standard describes a series of 20 American Society for Testing and Materials (ASTM) standard practices, guides, and methods for use in the prediction of neutron-induced changes in light water reactor (LWR) pressure vessel (PV) and support structure steels throughout a PV's service life. Some of these are existing ASTM standards, some are ASTM standards that have been modified, and some are new ASTM standards. These standards are periodically revised to assume their applicability during the 40-yr (32 effective full-power years) design license period for a nuclear power plant. They are now under review by two new ASTM plant life extension task groups: E10.05.11 on physics dosimetry and E10.02.11 on metallurgy. A brief review on the current application of these standards and a discussion of the status of work to verify the accuracy of derived physics-dosimetry parameter values is presented in this paper

  16. Influence of Chromium-Cobalt-Molybdenum Alloy (ASTM F75 on Bone Ingrowth in an Experimental Animal Model

    Directory of Open Access Journals (Sweden)

    Jésica Zuchuat

    2017-12-01

    Full Text Available Cr-Co-Mo (ASTM F75 alloy has been used in the medical environment, but its use as a rigid barrier membrane for supporting bone augmentation therapies has not been extensively investigated. In the present study, Cr-Co-Mo membranes of different heights were placed in New Zealand white, male rabbit tibiae to assess the quality and volume of new bone formation, without the use of additional factors. Animals were euthanized at 20, 30, 40, and 60 days. Bone formation was observed in all of the cases, although the tibiae implanted with the standard membranes reached an augmentation of bone volume that agreed with the density values over the timecourse. In all cases, plasmatic exudate was found under the membrane and in contact with the new bone. Histological analysis indicated the presence of a large number of chondroblasts adjacent to the inner membrane surface in the first stages, and osteoblasts and osteocytes were observed under them. The bone formation was appositional. The Cr-Co-Mo alloy provides a scaffold with an adequate microenvironment for vertical bone volume augmentation, and the physical dimensions and disposition of the membrane itself influence the new bone formation.

  17. Influence of Chromium-Cobalt-Molybdenum Alloy (ASTM F75) on Bone Ingrowth in an Experimental Animal Model.

    Science.gov (United States)

    Zuchuat, Jésica; Berli, Marcelo; Maldonado, Ysaí; Decco, Oscar

    2017-12-26

    Cr-Co-Mo (ASTM F75) alloy has been used in the medical environment, but its use as a rigid barrier membrane for supporting bone augmentation therapies has not been extensively investigated. In the present study, Cr-Co-Mo membranes of different heights were placed in New Zealand white, male rabbit tibiae to assess the quality and volume of new bone formation, without the use of additional factors. Animals were euthanized at 20, 30, 40, and 60 days. Bone formation was observed in all of the cases, although the tibiae implanted with the standard membranes reached an augmentation of bone volume that agreed with the density values over the timecourse. In all cases, plasmatic exudate was found under the membrane and in contact with the new bone. Histological analysis indicated the presence of a large number of chondroblasts adjacent to the inner membrane surface in the first stages, and osteoblasts and osteocytes were observed under them. The bone formation was appositional. The Cr-Co-Mo alloy provides a scaffold with an adequate microenvironment for vertical bone volume augmentation, and the physical dimensions and disposition of the membrane itself influence the new bone formation.

  18. Weldability examination of ASTM A 240 S41500 martensitic stainless steel by thermal cycles simulation testings

    Directory of Open Access Journals (Sweden)

    Alberto Velázquez-del Rosario

    2015-07-01

    Full Text Available The weldability assets of ASTM A 240 S41500 (ASTM A 240/A 240M martensitic stainless steel are presented through the study of the effects of single and double thermal weld cycles on mechanical properties and microstructure of base metal (BM and the artificial heat affected zone (HAZ created by thermal weld simulations. For single cycles, separate peak temperatures of 1000 ºC/12 s and 1350 ºC/12 s (cooling times: 12 s in both cases were evaluated, whilst two combinations of peak temperatures: (1350 ºC/5 s + 1000 ºC/5 s ºC and (1350 ºC/12 s + 1000 ºC/12 s ºC (cooling times: 5 s and 12 s, were applied for double cycles. Post weld heat treatment (PWHT with short and long holding times were applied and Vickers hardness, impact toughness and metallographic examinations were used in order to assess mechanical and metallographic properties in the as-simulated (no heat treated and postweld heat treated conditions. Best properties of the welded joint for double thermal weld cycles with long holding times were reached, which reveals the good weldability and applicability of the tested material in post weld heat treated conditions.

  19. Estimation of improved productivity based on materials substitution in high temperature applications. Use of alloy ASTM A-335 P91

    International Nuclear Information System (INIS)

    Serna, J A; Afanador, W

    2001-01-01

    In ECOPETROL-ICP was carried out an evaluation of the mechanical and micro structural properties of modified 9 Cr-1 Mo alloy, ASTM A-335 Gr. P91, finding higher strength mechanical properties, allowable stresses and creep rupture strength, than the conventional 9 Cr-1 Mo alloy, ASTM A-335 Gr. P9, recommending the alloy P91 as substitute tube material in the radiation zone of the Visbreaking heater of Cartagena's refinery (furnace in revamping process). The results obtained permit a thickness reduction of radiation tubes of material P91 close to 25% and increase the internal volume tube over up 8%, which is a parameter to consider in improving productivity and efficiency process. Also would be obtained a significant savings cost in the material among 5 and 10%. Additionally, expectations of both design and remaining useful life would be seen extensively favored with this change of alloy

  20. Mechanical behaviour of Astm A 297 grade Hp joints welded using different processes

    International Nuclear Information System (INIS)

    Emygdio, Paulo Roberto Oliveira; Zeemann, Annelise; Almeida, Luiz Henrique de

    1996-01-01

    The influence of different arc welding processes on mechanical behaviour was studied for cast heat resistant stainless steel welded joints, in the as welded conditions. ASTM A 297 grade HP with niobium and niobium/titanium additions were welded following three different welding procedures, using shielded metal arc welding gas tungsten arc welding and plasma arc welding, in six welded joints. The welded joint mechanical behaviour was evaluated by ambient temperature and 870 deg C tensile tests; and creep tests at 900 deg C and 50 MPa. Mechanical test results showed that the welding procedure qualification following welding codes is not suitable for high temperature service applications. (author)

  1. 78 FR 64475 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe (Over 41/2

    Science.gov (United States)

    2013-10-29

    ... stress levels. Alloy pipes made to ASTM A-335 standard must be used if temperatures and stress levels..., or pressure pipe applications. B. Finished and unfinished oil country tubular goods (OCTG), if covered by the scope of another antidumping duty order from the same country. If not covered by such an...

  2. 40 CFR 94.5 - Reference materials.

    Science.gov (United States)

    2010-07-01

    ... for Distillation of Petroleum Products at Atmospheric Pressure 94.108 ASTM D 93-02, Standard Test... Method for API Gravity of Crude Petroleum and Petroleum Products (Hydrometer Method) 94.108 ASTM D 445-01... Viscosity) 94.108 ASTM D 613-01, Standard Test Method for Cetane Number of Diesel Fuel Oil 94.108 ASTM D...

  3. Testing of adsorbents used in nuclear power plant air cleaning systems using the open-quotes Newclose quotes standards

    International Nuclear Information System (INIS)

    Freeman, W.P.

    1993-01-01

    Ever since the publication of the NRC Information Notice No. 87-32: Deficiencies in the Testing of Nuclear-Grade Activated Charcoal, nuclear power facilities in the US have struggled in their efforts to open-quotes...review the information for applicability to their facilities and consider action, if appropriate ...close quotes as stated in the notice. The encouragement of resident NRC inspectors at some nuclear power facilities has prompted a variety of responses ranging from no change at all in testing requirements to contemplated changes in plant technical specifications. This confusion is the result of a couple factors. The first factor is the lack of a current revision to NRC Regulatory Guide 1.52, the basic document used in nuclear power plant technical specifications for the testing of engineered-safety feature (ESF) post accident air cleaning systems. The second factor is the standards that have been written since the last revision of Reg. Guide 1.52 which include two revision of ANSI N509 and N510, two revisions of RDT M16-1T, two version of ASTM D3803, two versions of ASTM D4069, and three versions of an SME code AG-1. Few of the standards and codes listed above are commensurate with each other and, thus, present a nearly insolvable maze to the HVAC engineer asked to upgrade adsorbent testing requirements following the standards. This paper describes the authors experience with a number of nuclear power facilities in their efforts to meet the requirements of the new standards of testing adsorbents from nuclear power plant air cleaning systems. The existing standards are discussed in light of the current state of the art for adsorbent testing of adsorbent media from nuclear air treatment systems. Test results are presented showing the impact of new test requirements on acceptance criteria when compared to the old test requirements and recommendations are offered for solution of this testing problem in the future. 12 refs., 5 tabs

  4. Effects of the normalizing time and temperature on the impact properties of ASTM A-516 grade 70 steel

    International Nuclear Information System (INIS)

    Carneiro, T.; Cescon, T.

    1982-01-01

    The influence of normalizing time and temperature, as well as the plate thickness, on the impact properties of ASTM A-516 grade 70 steel, is studied. Results show that different normalizing conditions may lead to equivalent microstructure with different impact properties. Normalizing conditions that cause low cooling rate in the critical zone exhibit banded microstructure with inferior impact properties. (Author) [pt

  5. Advancements in internationally accepted standards for radiation processing

    International Nuclear Information System (INIS)

    Farrar, H. IV; Derr, D.D.; Vehar, D.W.

    1993-01-01

    Subcommittees of the American Society for Testing and Materials (ASTM) are developing standards on various aspects of radiation processing. Nine standards on how to select and calibrate dosimeters, where to put them, how many to use, and how to use individual types of dosimeter systems have been published. The group is also developing standards on how to use gamma, electron beam, and X-ray facilities for radiation processing, and a standard on how to treat dose uncertainties. Efforts are underway to promote inclusion of these standards into procedures now being developed by government agencies and by international groups such as the United Nations' International Consultative Group on Food Irradiation (ICGFI) in order to harmonize regulations and help avoid trade barriers. Standards on good irradiation practices for meat and poultry and for fresh fruits, and for the irradiation of seafood and spices have been developed. These food-related standards are based on practices previously published by ICGFI. Standards for determining doses for radiation hardness testing of electronics have been developed. Standards on the Fricke and TLD dosimetry systems are equally useful in other radiation processing applications. (Author)

  6. Standardizing Activation Analysis: New Software for Photon Activation Analysis

    Science.gov (United States)

    Sun, Z. J.; Wells, D.; Segebade, C.; Green, J.

    2011-06-01

    Photon Activation Analysis (PAA) of environmental, archaeological and industrial samples requires extensive data analysis that is susceptible to error. For the purpose of saving time, manpower and minimizing error, a computer program was designed, built and implemented using SQL, Access 2007 and asp.net technology to automate this process. Based on the peak information of the spectrum and assisted by its PAA library, the program automatically identifies elements in the samples and calculates their concentrations and respective uncertainties. The software also could be operated in browser/server mode, which gives the possibility to use it anywhere the internet is accessible. By switching the nuclide library and the related formula behind, the new software can be easily expanded to neutron activation analysis (NAA), charged particle activation analysis (CPAA) or proton-induced X-ray emission (PIXE). Implementation of this would standardize the analysis of nuclear activation data. Results from this software were compared to standard PAA analysis with excellent agreement. With minimum input from the user, the software has proven to be fast, user-friendly and reliable.

  7. Standardizing Activation Analysis: New Software for Photon Activation Analysis

    International Nuclear Information System (INIS)

    Sun, Z. J.; Wells, D.; Green, J.; Segebade, C.

    2011-01-01

    Photon Activation Analysis (PAA) of environmental, archaeological and industrial samples requires extensive data analysis that is susceptible to error. For the purpose of saving time, manpower and minimizing error, a computer program was designed, built and implemented using SQL, Access 2007 and asp.net technology to automate this process. Based on the peak information of the spectrum and assisted by its PAA library, the program automatically identifies elements in the samples and calculates their concentrations and respective uncertainties. The software also could be operated in browser/server mode, which gives the possibility to use it anywhere the internet is accessible. By switching the nuclide library and the related formula behind, the new software can be easily expanded to neutron activation analysis (NAA), charged particle activation analysis (CPAA) or proton-induced X-ray emission (PIXE). Implementation of this would standardize the analysis of nuclear activation data. Results from this software were compared to standard PAA analysis with excellent agreement. With minimum input from the user, the software has proven to be fast, user-friendly and reliable.

  8. Standard recommended practice for examination of fuel element cladding including the determination of the mechanical properties

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Guidelines are provided for the post-irradiation examination of fuel cladding and to achieve better correlation and interpretation of the data in the field of radiation effects. The recommended practice is applicable to metal cladding of all types of fuel elements. The tests cited are suitable for determining mechanical properties of the fuel elements cladding. Various ASTM standards and test methods are cited

  9. Standardization Efforts for Mechanical Testing and Design of Advanced Ceramic Materials and Components

    Science.gov (United States)

    Salem, Jonathan A.; Jenkins, Michael G.

    2003-01-01

    Advanced aerospace systems occasionally require the use of very brittle materials such as sapphire and ultra-high temperature ceramics. Although great progress has been made in the development of methods and standards for machining, testing and design of component from these materials, additional development and dissemination of standard practices is needed. ASTM Committee C28 on Advanced Ceramics and ISO TC 206 have taken a lead role in the standardization of testing for ceramics, and recent efforts and needs in standards development by Committee C28 on Advanced Ceramics will be summarized. In some cases, the engineers, etc. involved are unaware of the latest developments, and traditional approaches applicable to other material systems are applied. Two examples of flight hardware failures that might have been prevented via education and standardization will be presented.

  10. Biodiesel Fuel Quality and the ASTM Standard

    Science.gov (United States)

    Biodiesel is usually produced from vegetable oils, animal fats and used cooking oils with alternative feedstocks such as algae receiving increasing interest. The transesterification reaction which produces biodiesel also produces glycerol and proceeds stepwise via mono- and diacylglycerol intermedia...

  11. Collection Efficiencies of Various Airborne Spray Flux Samplers Used in Aerial Application Research

    Science.gov (United States)

    2008-01-01

    provided by ASTM Standard E1260: Standard Test Method for Determining Liquid Drop Size Characteristics in a Spray Using Optical Nonimaging Light...Size Characteristics in a Spray Using Optical Nonimaging Light-Scattering Instruments,” Annual Book of ASTM Stan- dards, ASTM International, West

  12. Final Report, Volume 4, The Development of Qualification Standards for Cast Super Duplex Stainless Steel (2507 Wrought Equivalent)

    Energy Technology Data Exchange (ETDEWEB)

    Hariharan, Vasudevan; Lundin, Carl, W.

    2005-09-30

    The objective of the program is to determine the suitability of ASTM A923 Standard Test methods for Detecting Detrimental Intermetallic Phase in Wrought Duplex Austenitic-Ferritic Stainless Steels for 25 Cr Cast Super Duplex Stainless Steels (ASTM A890-5A). Different tests were carried out on the materials procured from various steel foundries as stated in the ASTM A923. The foundries were designated as Foundry A, B, C and D. All the materials were foundry solution annealed. Materials from Foundry D were solution heat treated at The University of Tennessee also and then they were subjected to heat treatment schedule which was derived from the testing of wrought DSS to establish the A923 specification. This was possible because the material from the same heat was sufficient for conducting the full scope of heat treatment. This was done prior to carrying out various other tests. Charpy samples were machined. The Ferrite content was measured in all the Charpy samples using Feritscope® and ASTM E562 Manual Point Count Method. After the ferrite content was measured the samples were sent to AMC-Vulcan, Inc. in Alabama to conduct the Charpy impact test based on ASTM A923 Test Method B. This was followed by etch testing and corrosion analysis based on ASTM A923 Test Methods A and C respectively at University of Tennessee. Hardness testing using Rockwell B and C was also carried out on these samples. A correlation was derived between all the three test methods and the best method for evaluating the presence of intermetallic in the material was determined. The ferrite content was correlated with the toughness values. Microstructural analysis was carried out on the etch test samples using Scanning Electron Microscopy in order to determine if intermetallic phases were present. The fracture surfaces from Charpy test specimens were also observed under SEM in order to determine the presence of any cracks and whether it was a brittle or a ductile fracture. A correlation was

  13. Standard classification of uranium resources-an illustrative example

    International Nuclear Information System (INIS)

    Krishna, P.M.; Babitzke, H.R.; Curry, D.; Masters, C.D.; McCammon, R.B.; Noble, R.B.; Rodriguez, J.A.; Schanz, J.J.; Schreiber, H.W.

    1983-01-01

    An example illustrates the use of ASTM Standard E901-82, Classification System for Uranium Resources. The example demonstrates the dynamic nature of the process of classification and attests to the necessity of addressing both the aggregate needs of broad-scale resource planning and the specific needs of individual property evaluation. Problems that remain in fixing the classification of a given uranium resource include the uncertainty in estimating the quantity of undiscovered resources and resolving the differences that may exist in deciding when the drill-hole spacing is adequate to determine the tonnage and grade of discovered resources

  14. 46 CFR 175.600 - Incorporation by reference.

    Science.gov (United States)

    2010-10-01

    ... Vessels Under 61 Meters (200 feet) in Length, 1983 (“ABS Steel Vessel Rules (Meters)”) 177.300. Rules..., Standard Practice for Operating Salt Spray (Fog) Apparatus (“ASTM B 117”) 175.400. ASTM B 122/B 122M-95... (“ASTM D 93”) 175.400. ASTM D 635-97, Standard test Method for Rate of Burning and or Extent and Time of...

  15. standards used for quality control of nuclear fuels

    International Nuclear Information System (INIS)

    Guereli, L; Can, S.

    1997-01-01

    Nuclear fuels and fuel materials are subject to stringent restrictions as to their quality. The standards and regulations that apply vary according to reactor type and country and the standards are stated in the quality assurance documents. The concept of quality assurance has altered the conventional quality control tests and procedures, defining which control tests are to be applied and how. Although most of the tests and measurements allow the determination of tolerances to be decided according to the agreement between the buyer and the seller, exacting procedures apply to which instruments and equipment are used for these tests and measurements, how these instruments are standardized.Detailed explanations of test methods and their documentation is a requirement in all standards. The purpose of this work is to study which standards, tests and measurements apply to the nuclear fuel production. Only the standards that apply to various stages of the nuclear fuel production (powder preparation, pellet production, fuel element and fuel assembly fabrication) are reviewed. Process and documentation control, design and licensing requirements and the frequency of inspections are quality assurance subjects. Some ASTM standards are given as examples

  16. Standardized physics-dosimetry for US pressure vessel cavity surveillance programs

    International Nuclear Information System (INIS)

    Ruddy, F.H.; McElroy, W.N.; Lippincott, E.P.

    1984-01-01

    Standardized Physics-Dosimetry procedures and data are being developed and tested for monitoring the neutron doses accumulated by reactor pressure vessels (PV) and their support structures. These procedures and data are governed by a set of 21 ASTM standard practices, guides, and methods for the prediction of neutron-induced changes in light water reactor (LWR) PVs and support structure steels throughout the service life of the PV. This paper summarizes the applications of these standards to define the selection and deployment of recommended dosimetry sets, the selection of dosimetry capsules and thermal neutron shields, the placement of dosimetry, the methods of measurement of dosimetry sensor reaction products, data analysis procedures, and uncertainty evaluation procedures. It also describes the validation of these standards both by in-reactor testing of advanced PV cavity surveillance physics-dosimetry and by data development. The use of these standards to guide selection and deployment of advanced dosimetry sets for commercial reactors is also summarized

  17. Standard guide for conducting exfoliation corrosion tests in aluminum alloys

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1992-01-01

    1.1 This guide differs from the usual ASTM standard in that it does not address a specific test. Rather, it is an introductory guide for new users of other standard exfoliation test methods, (see Terminology G 15 for definition of exfoliation). 1.2 This guide covers aspects of specimen preparation, exposure, inspection, and evaluation for conducting exfoliation tests on aluminum alloys in both laboratory accelerated environments and in natural, outdoor atmospheres. The intent is to clarify any gaps in existent test methods. 1.3 The values stated in SI units are to be regarded as the standard. The inch-pound units given in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  18. Standard method of test for atom percent fission in uranium fuel - radiochemical method

    International Nuclear Information System (INIS)

    Anon.

    The determination of the U at. % fission that has occurred in U fuel from an analysis of the 137 Cs ratio to U ratio after irradiation is described. The method is applicable to high-density, clad U fuels (metal, alloys, or ceramic compounds) in which no separation of U and Cs has occurred. The fuels are best aged for several months after irradiation in order to reduce the 13-day 136 Cs activity. The fuel is dissolved and diluted to produce a solution containing a final concentration of U of 100 to 1000 mg U/l. The 137 Cs concentration is determined by ASTM method E 320, for Radiochemical Determination of Cesium-137 in Nuclear Fuel Solutions, and the U concentration is determined by ASTM method E 267, for Determination of Uranium and Plutonium Concentrations and Isotopic Abundances, ASTM method E 318, for Colorimetric Determination of Uranium by Controlled-Potential Coulometry. Calculations are given for correcting the 137 Cs concentration for decay during and after irradiation. The accuracy of this method is limited, not only by the experimental errors with which the fission yield and the half-life of 137 Cs are known

  19. Standardized accounting ashore for afloat activities

    OpenAIRE

    Burr, Michael J.

    1996-01-01

    With limited resources and reduced funding for Naval forces, there is a need to standardize accounting ashore for all afloat activities. The purpose of this thesis was to review the framework for standardization of inventory reporting afloat under one stores (inventory) accounting system, referred to as the Material Financial Control System-Retail (MFCS-Retail). Additional analysis was conducted on general funds obligational reporting for afloat Operating Targets (OPTARS) and the conversion t...

  20. Standard Guide for Preparing Characterization Plans for Decommissioning Nuclear Facilities

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This standard guide applies to developing nuclear facility characterization plans to define the type, magnitude, location, and extent of radiological and chemical contamination within the facility to allow decommissioning planning. This guide amplifies guidance regarding facility characterization indicated in ASTM Standard E 1281 on Nuclear Facility Decommissioning Plans. This guide does not address the methodology necessary to release a facility or site for unconditional use. This guide specifically addresses: 1.1.1 the data quality objective for characterization as an initial step in decommissioning planning. 1.1.2 sampling methods, 1.1.3 the logic involved (statistical design) to ensure adequate characterization for decommissioning purposes; and 1.1.4 essential documentation of the characterization information. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate saf...

  1. Evaluation of Suitability of Non-Standardized Test Block for Ultrasonic Testing

    International Nuclear Information System (INIS)

    Kwon, Ho Young; Lim, Jong Ho; Kang, Sei Sun

    2000-01-01

    Standard Test Block(STB) for UT(Ultrasonic Testing) is a block approved by authoritative for material, shape and quality. STB is used for characteristic tests, sensitivity calibration and control of the time base range of UT inspection devices. The material, size and chemical components of STB should be strictly controlled to meet the related standards such as ASTM and JIS because it has an effect upon sensitivity, resolution and reproductivity of UT. The STBs which are not approved are sometimes used because the qualified STBs are very expensive. So, the purpose of this study is to survey the characteristics, quality and usability of Non-Standardized Test Blocks. Non-Standardized Test Blocks did not meet the standard requirements in size or chemical components, and ultrasonic characteristics. Therefore if the Non-Standardized Test Blocks are used without being tested, it's likely to cause errors in detecting the location and measuring the size of the defects

  2. Evaluation of Cement, Lime, and Asphalt Amended Municipal Solid Waste Incinerator Residues

    Science.gov (United States)

    1989-09-01

    the lime column over time ( Atlas & Bartha , 1987). Certainly, a more extensive evaluation of the lime amended residue’s microbial activity is required...4.02 ASTM D 1559 (1988) Annual Book of ASTM Standards: Road & Paving Materials; Traveled Surface Characteristics, Sec 4, Vol 4.03 Atlas , R. & R. Bartha ...1987) Microbial Ecology : Fundamentals & Applications, Benjamin-Cummings, Menlo, CA Barrow N., J. Bowden, A. Posner, & J. Quirk (1981) Describing the

  3. Current global standards for chemical protective clothing: how to choose the right protection for the right job?

    Science.gov (United States)

    VAN WELY, Eric

    2017-01-01

    The first standards for chemical protective clothing (CPC) emerged mid to late 1980’s and have evolved since as most standards are revisited every 5 yr. Over the past years, we have also seen a strengthening of the chemical and worker protection legislation around the globe (various forms of REACH) but also protection of workers. The most prevalent standards originate under the auspices of the International Standards Organisation (ISO), European Committee for Standardisation (CEN) or under various US standards organisations (e.g. NFPA, ASTM). Protective clothing against hazardous materials is required in many of the professional and non-professional activities of everyday life. Effective and adequate protection is important in many scenarios from household (e.g. cleaning agents, peroxides, acids and bases, paints), to agricultural (e.g. fuel, pesticides), to medical (e.g. pharmaceuticals and active ingredients), to industrial production (e.g. petro-chemicals, chemicals, paints, adhesive and coatings) but also manufacturing of many products (e.g. light bulbs, cars, semi-conductors), during various emergency activities (e.g. boat, rail or road accidents as well as fire-fighting in an urban and industrial setting), and finally, military operations or response to incidents of terrorism. Nevertheless, CPC must remain the last line of defence whenever possible through a preference for less hazardous chemicals, less dangerous processes and handling operations, and by engineering controls to reduce and minimise human contact with the chemicals. This article provides information about the selection, use, care and maintenance (SUCAM) of protective clothing against chemical and microbiological hazards. PMID:29046493

  4. 40 CFR 761.19 - References.

    Science.gov (United States)

    2010-07-01

    ... Products (General Bomb Method) § 761.71(b)(2)(vi) ASTM D 240-87 Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuel by Bomb Calorimeter § 761.71(b)(2)(vi) ASTM D 482-87 Standard Test Method... in New and Used Petroleum Products (Bomb Method) § 761.71(b)(2)(vi) ASTM D 923-86 Standard Test...

  5. Moessbauer spectroscopy study on the corrosion resistance of plasma nitrided ASTM F138 stainless steel in chloride solution

    International Nuclear Information System (INIS)

    Souza, S.D. de; Olzon-Dionysio, M.; Basso, R.L.O.; Souza, S. de

    2010-01-01

    Plasma nitriding of ASTM F138 stainless steel samples has been carried out using dc glow discharge under 80% H 2 -20% N 2 gas mixture, at 673 K, and 2, 4, and 7 h time intervals, in order to investigate the influence of treatment time on the microstructure and the corrosion resistance properties. The samples were characterized by scanning electron microscopy, glancing angle X-ray diffraction and conversion electron Moessbauer spectroscopy, besides electrochemical tests in NaCl aerated solution. A modified layer of about 6 μm was observed for all the nitrided samples, independent of nitriding time. The X-ray diffraction analysis shows broad γ N phase peaks, signifying a great degree of nitrogen supersaturation. Besides γ N, the Moessbauer spectroscopy results indicated the occurrence of γ' and ε phases, as well as some other less important phases. Corrosion measurements demonstrate that the plasma nitriding time affects the corrosion resistance and the best performance is reached at 4 h treatment. It seems that the ε/γ' fraction ratio plays an important role on the resistance corrosion. Additionally, the Moessbauer spectroscopy was decisive in this study, since it was able to identify and quantify the iron phases that influence the corrosion resistance of plasma nitrided ASTM F138 samples.

  6. Phases Evolution of an ASTM 335 steel under continuous cooling P91

    International Nuclear Information System (INIS)

    Carrizo, D.A; Danon, C.A; Ramos, C.P

    2012-01-01

    This paper studies the influence of the cooling rate on phase transformations and the resulting microstructure in continuous cooling cycles for an ASTM A335 P91 steel, under fixed austenization conditions. The CCT (Continuous Cooling Transformation) diagram of this material is reported in the literature, so the main phase fields are known. The final structure of the samples depends on the austenitic grain size and the cooling rate. The studied samples were austenized at 1050 o C for 30 minutes and then cooled at different rates between 50 o C/h and 300 o C/h. The identification and characterization of the phases was carried out by using Scanning Electron Microscopy, X-ray Diffraction and Moessbauer Spectroscopy. From the results so obtained, additions to the CCT diagram of the material are proposed, providing new information to it

  7. Proposal and Evaluation of Subordinate Standard Solar Irradiance Spectra for Applications in Solar Energy Systems

    Energy Technology Data Exchange (ETDEWEB)

    Habte, Aron M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Jessen, Wilko [German Aerospace Center (DLR); Wilbert, Stefan [German Aerospace Center (DLR); Gueymard, Christian A. [Solar Consulting Services; Polo, Jesus [CIEMAT; Bian, Zeqiang [China Meteorological Administration; Driesse, Anton [Photovoltaic Performance Labs; Marzo, Aitor [University of Antofagasta; Armstrong, Peter [Masdar Institute of Science & Technology; Vignola, Frank [University of Oregon; Ramirez, Lourdes [CIEMAT

    2018-04-01

    Reference solar irradiance spectra are needed to specify key parameters of solar technologies such as photovoltaic cell efficiency, in a comparable way. The IEC 60904-3 and ASTM G173 standards present such spectra for Direct Normal Irradiance (DNI) and Global Tilted Irradiance (GTI) on a 37 degrees tilted sun-facing surface for one set of clear-sky conditions with an air mass of 1.5 and low aerosol content. The IEC/G173 standard spectra are the widely accepted references for these purposes. Hence, the authors support the future replacement of the outdated ISO 9845 spectra with the IEC spectra within the ongoing update of this ISO standard. The use of a single reference spectrum per component of irradiance is important for clarity when comparing and rating solar devices such as PV cells. However, at some locations the average spectra can differ strongly from those defined in the IEC/G173 standards due to widely different atmospheric conditions and collector tilt angles. Therefore, additional subordinate standard spectra for other atmospheric conditions and tilt angles are of interest for a rough comparison of product performance under representative field conditions, in addition to using the main standard spectrum for product certification under standard test conditions. This simplifies the product selection for solar power systems when a fully-detailed performance analysis is not feasible (e.g. small installations). Also, the effort for a detailed yield analyses can be reduced by decreasing the number of initial product options. After appropriate testing, this contribution suggests a number of additional spectra related to eight sets of atmospheric conditions and tilt angles that are currently considered within ASTM and ISO working groups. The additional spectra, called subordinate standard spectra, are motivated by significant spectral mismatches compared to the IEC/G173 spectra (up to 6.5%, for PV at 37 degrees tilt and 10-15% for CPV). These mismatches

  8. Activities of HPS standards committee in environmental remediation

    International Nuclear Information System (INIS)

    Stencel, J.R.

    1994-01-01

    The Health Physics Society (HPS) develops American National Standards in the area of radiation protection using methods approved by the American National Standards Institute (ANSI). Two of its sections, Environmental Health Physics and Contamination Limits, have ongoing standards development which are important to some environmental remediation efforts. This paper describes the role of the HPS standards process and indicates particular standards under development which will be of interest to the reader. In addition, the authors solicit readers to participate in the voluntary standards process by either joining active working groups (WG) or suggesting appropriate and relevant topics which should be placed into the standards process

  9. Changes of the mechanical properties of ASTM A 533 type B class 1 (JRQ) steel used in pressure vessels of nuclear power plants

    International Nuclear Information System (INIS)

    Balderrama, Juan J.; Iorio, Antonio F.

    1999-01-01

    The steels used in pressure vessels generally present a non-homogenous microstructure across the thickness of their walls due to their manufacturing process. Average thickness being between 200-250 mm also makes the problem more serious. These facts lead us to think that the variation affects not only microstructure, but also mechanical properties. For this reason the methodology for the evaluation of materials should be standardized for their use before and after radiation by means of a surveillance program which allows us to verify the conditions of the steel of the pressure vessel by using Charpy-v, tensile and fracto-mechanics specimens inside the reactor to obtain information about the condition of the pressure vessel material. In order to analyze these changes, tests were carried out using Charpy-v specimens with different orientation inside the block representing the wall thickness and the corresponding ductile-to-brittle transition curves were made for each direction. The orientations to be considered will be four in all and will be those called TL, LT, ST and LS by ASTM E 399 (1993). The conclusions reached arise from a comparative analysis of the results obtained for each orientation under study and confirm the recommendation by Standards regarding the selection of the TL orientation as the most conservative. (author)

  10. Control Systems Cyber Security Standards Support Activities

    Energy Technology Data Exchange (ETDEWEB)

    Robert Evans

    2009-01-01

    The Department of Homeland Security’s Control Systems Security Program (CSSP) is working with industry to secure critical infrastructure sectors from cyber intrusions that could compromise control systems. This document describes CSSP’s current activities with industry organizations in developing cyber security standards for control systems. In addition, it summarizes the standards work being conducted by organizations within the sector and provides a brief listing of sector meetings and conferences that might be of interest for each sector. Control systems cyber security standards are part of a rapidly changing environment. The participation of CSSP in the development effort for these standards has provided consistency in the technical content of the standards while ensuring that information developed by CSSP is included.

  11. Proposal and Evaluation of Subordinate Standard Solar Irradiance Spectra: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Habte, Aron M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Wilbert, Stefan [German Aerospace Center (DLR); Jessen, Wilko [German Aerospace Center (DLR); Gueymard, Chris [Solar Consulting Services; Polo, Jesus [CIEMAT; Bian, Zeqiang [China Meteorological Administration; Driesse, Anton [Photovoltaic Performance Labs; Marzo, Aitor [University of Antofagasta; Armstrong, Peter [Masdar Institute of Science & Technology; Vignola, Frank [University of Oregon; Ramirez, Lourdes [CIEMAT

    2018-04-12

    This paper introduces a concept for global tilted irradiance (GTI) subordinate standard spectra to supplement the current standard spectra used in solar photovoltaic applications as defined in ASTM G173 and IEC60904. The proposed subordinate standard spectra correspond to atmospheric conditions and tilt angles that depart significantly from the main standard spectrum, and they can be used to more accurately represent various local conditions. For the definition of subordinate standard spectra cases with an elevation 1.5 km above sea level, the question arises whether the air mass should be calculated including a pressure correction or not. This study focuses on the impact of air mass used in standard spectra, and it uses data from 29 locations to examine which air mass is most appropriate for GTI and direct normal irradiance (DNI) spectra. Overall, it is found that the pressure-corrected air mass of 1.5 is most appropriate for DNI spectra. For GTI, a non-pressure-corrected air mass of 1.5 was found to be more appropriate.

  12. Studies on the welding of heavy-section ASTM A542 Cl. 1 steel for large-sized pressure vessels

    International Nuclear Information System (INIS)

    Shimizu, Shigeki; Aota, Toshiichi; Kasahara, Masayuki

    1977-01-01

    ASTM A 542, Cl. 1 steel was developed and standardized recently, and is excellent in the high temperature strength and toughness as compared with conventionally used A 387, Grade 22 steel, accordingly the application to large pressure vessels is planned. This steel is a low alloy steel, and in case of large thickness, the possibility of cracking in the welded part is large. Also many times of annealing are required for the prevention of welding cracking, the relieving of residual stress, and the softening of hardened portion, but the possibility of cracking during stress-relieving annealing is large. In this study, Tekken type cracking test was carried out by coated electrode welding, and restricted cracking test was carried out by submerged arc welding of the A 542, Cl. 1 steel and A 387, Grade 22 steel, thus the welding cracking property was investigated, and the optimal welding conditions were selected. Also the test of cracking during the stress-relieving annealing of both steels was carried out, and the method of preventing the cracking was studied. The optimal conditions of stress-relieving annealing were selected, and the mechanism of the cracking was clarified. The mechanical properties of the joints welded and stress-relieved under the selected conditions were confirmed. (Kako, I.)

  13. Effect of using the double layer technique on the microstructure, microhardness and residual stress of welded ASTM A516 GR70 structural steel

    International Nuclear Information System (INIS)

    Oliveira, George Luiz Gomes de; Miranda, Helio Cordeiro de

    2010-01-01

    The aim of this work is to evaluate the effect of using the double layer technique on the microstructure, microhardness and residual stresses of welded ASTM A516 Gr70 structural steel. Samples were welded with the same welding parameters and two types of chamfers, while the samples welded using the double layer technique underwent a buttering process on their chamfer face. Residual stress measurement was accomplished through x-ray diffraction, using a mini diffractometer for measurement in field. Metallographic analysis was accomplished in the transverse section of the welded joint, using optic microscopy and scanning electron microscopy. The double layer technique showed that can be used in the welding of ASTM A516 Gr70 steel, because, besides promote a refinement and a drawing back of the CG-HAZ, it increased compressive residual stress in the whole surface of the analyzed samples.(author)

  14. Online purchases of an expanded range of condom sizes in comparison to current dimensional requirements allowable by US national standards.

    Science.gov (United States)

    Cecil, Michael; Warner, Lee; Siegler, Aaron J

    2013-11-01

    Across studies, 35-50% of men describe condoms as fitting poorly. Rates of condom use may be inhibited in part due to the inaccessibility of appropriately sized condoms. As regulated medical devices, condom sizes conform to national standards such as those developed by the American Society for Testing and Materials (ASTM) or international standards such as those developed by the International Organisation for Standardisation (ISO). We describe the initial online sales experience of an expanded range of condom sizes and assess uptake in relation to the current required standard dimensions of condoms. Data regarding the initial 1000 sales of an expanded range of condom sizes in the United Kingdom were collected from late 2011 through to early 2012. Ninety-five condom sizes, comprising 14 lengths (83-238mm) and 12 widths (41-69mm), were available. For the first 1000 condom six-pack units that were sold, a total of 83 of the 95 unique sizes were purchased, including all 14 lengths and 12 widths, and both the smallest and largest condoms. Initial condom purchases were made by 572 individuals from 26 countries. Only 13.4% of consumer sales were in the ASTM's allowable range of sizes. These initial sales data suggest consumer interest in an expanded choice of condom sizes that fall outside the range currently allowable by national and international standards organisations.

  15. Effect of increased fuel temperature on emissions of oxides of nitrogen from a gas turbine combustor burning ASTM jet-A fuel

    Science.gov (United States)

    Marchionna, N. R.

    1974-01-01

    An annular gas turbine combustor was tested with heated ASTM Jet-A fuel to determine the effect of increased fuel temperature on the formation of oxides of nitrogen. Fuel temperature ranged from ambient to 700 K. The NOx emission index increased at a rate of 6 percent per 100 K increase in fuel temperature.

  16. Technology transfer through a network of standard methods and recommended practices - The case of petrochemicals

    Science.gov (United States)

    Batzias, Dimitris F.; Karvounis, Sotirios

    2012-12-01

    Technology transfer may take place in parallel with cooperative action between companies participating in the same organizational scheme or using one another as subcontractor (outsourcing). In this case, cooperation should be realized by means of Standard Methods and Recommended Practices (SRPs) to achieve (i) quality of intermediate/final products according to specifications and (ii) industrial process control as required to guarantee such quality with minimum deviation (corresponding to maximum reliability) from preset mean values of representative quality parameters. This work deals with the design of the network of SRPs needed in each case for successful cooperation, implying also the corresponding technology transfer, effectuated through a methodological framework developed in the form of an algorithmic procedure with 20 activity stages and 8 decision nodes. The functionality of this methodology is proved by presenting the path leading from (and relating) a standard test method for toluene, as petrochemical feedstock in the toluene diisocyanate production, to the (6 generations distance upstream) performance evaluation of industrial process control systems (ie., from ASTM D5606 to BS EN 61003-1:2004 in the SRPs network).

  17. Dosimetry standards for radiation processing

    International Nuclear Information System (INIS)

    Farrar, H. IV

    1999-01-01

    For irradiation treatments to be reproducible in the laboratory and then in the commercial environment, and for products to have certified absorbed doses, standardized dosimetry techniques are needed. This need is being satisfied by standards being developed by experts from around the world under the auspices of Subcommittee E10.01 of the American Society for Testing and Materials (ASTM). In the time period since it was formed in 1984, the subcommittee has grown to 150 members from 43 countries, representing a broad cross-section of industry, government and university interests. With cooperation from other international organizations, it has taken the combined part-time effort of all these people more than 13 years to complete 24 dosimetry standards. Four are specifically for food irradiation or agricultural applications, but the majority apply to all forms of gamma, x-ray, Bremsstrahlung and electron beam radiation processing, including dosimetry for sterilization of health care products and the radiation processing of fruits, vegetables, meats, spices, processed foods, plastics, inks, medical wastes and paper. An additional 6 standards are under development. Most of the standards provide exact procedures for using individual dosimetry systems or for characterizing various types of irradiation facilities, but one covers the selection and calibration of dosimetry systems, and another covers the treatment of uncertainties. Together, this set of standards covers essentially all aspects of dosimetry for radiation processing. The first 20 of these standards have been adopted in their present form by the International Organization of Standardization (ISO), and will be published by ISO in 1999. (author)

  18. China and IEC international standardization activities

    Institute of Scientific and Technical Information of China (English)

    Su Zhongmin; Guo Chenguang

    2006-01-01

    @@ International Electrotechnical Commission (IEC), one of the currently worlswide largest and most authoritative international standardization organizations,is specialized in developing and promulgating international standards for the electric and electronic fields, which are widespread adopted through out the world and play an important role in the international trade of electric and electronic products. Moreover, according to the 2005 statistics by the World Bank, the population of countries participating in the IEC activities accounts for 92% of the world total and their trade volume accounts for 95% of the global total.

  19. Microstructure evolution of ASTM 335 P91 steel, subjected to continuous cooling

    International Nuclear Information System (INIS)

    Carrizo, D.A; Danon, C.A; Ramos, C.P

    2012-01-01

    This paper studies the influence of the cooling rate on an isothermal phase transformations in ASTM A335 P91 steel, by the analysis of the resulting microstructure after several continuous cooling cycles under fixed austenization conditions. The CCT (Continuous Cooling Transformation) diagram of this material has already been reported in the literature, so the main phase fields are known, and they depend on the austenitic grain size and the cooling rate. Five samples were tested in a dilatometer, they were austenized and then cooled at different rates between 50 o C/h and 300 o C/h. The identification and characterization of the resulting phases was carried out by using Scanning Electron Microscopy, X-ray Diffraction and Mossbauer Spectroscopy. The obtained results allowed to add information about the presence of retained austenite and (Fe,Cr) 3 C - type carbides to the CCT diagram of the material (author)

  20. Final Report, Volume 4, The Develpoment of Qualification Standards forCast Super Duplex Stainless Steel (2507 Wrought Equivalent)

    Energy Technology Data Exchange (ETDEWEB)

    Hariharan, Vasudevan; Lundin, Carl, D.

    2005-09-30

    The objective of the program is to determine the suitability of ASTM A923 Standard Test methods for Detecting Detrimental Intermetallic Phase in Wrought Duplex Austenitic-Ferritic Stainless Steels for 25 Cr Cast Super Duplex Stainless Steels (ASTM A890-5A). Different tests were carried out on the materials procured from various steel foundries as stated in the ASTM A923. The foundries were designated as Foundry A, B, C and D. All the materials were foundry solution annealed. Materials from Foundry D were solution heat treated at The University of Tennessee also and then they were subjected to heat treatment schedule which was derived from the testing of wrought DSS to establish the A923 specification. This was possible because the material from the same heat was sufficient for conducting the full scope of heat treatment. This was done prior to carrying out various other tests. Charpy samples were machined. The Ferrite content was measured in all the Charpy samples using Feritscope{reg_sign} and ASTM E562 Manual Point Count Method. After the ferrite content was measured the samples were sent to AMC-Vulcan, Inc. in Alabama to conduct the Charpy impact test based on ASTM A923 Test Method B. This was followed by etch testing and corrosion analysis based on ASTM A923 Test Methods A and C respectively at University of Tennessee. Hardness testing using Rockwell B and C was also carried out on these samples. A correlation was derived between all the three test methods and the best method for evaluating the presence of intermetallic in the material was determined. The ferrite content was correlated with the toughness values. Microstructural analysis was carried out on the etch test samples using Scanning Electron Microscopy in order to determine if intermetallic phases were present. The fracture surfaces from Charpy test specimens were also observed under SEM in order to determine the presence of any cracks and whether it was a brittle or a ductile fracture. A correlation

  1. Summary and recommendations of the NRC/INEL Activated Carbon Testing Program

    International Nuclear Information System (INIS)

    Scarpellino, C.D.; Sill, C.W.

    1986-01-01

    The Committee on Nuclear Air and Gas Treatment (CONAGT) of the American Society of Mechanical Engineers (ASME) sponsored an interlaboratory testing program, round-robin, of nuclear-grade activated carbon. The results of this round-robin revealed gross differences in penetration of radio-labeled methyl iodide as measured by the various laboratories when using Method A of the ASTM D-3803-79 Standard. These differences prompted the Nuclear Regulatory Commission (NRC) to establish the NRC/INEL Activated Carbon Testing Program to determine the causes of these discrepancies and to provide recommendations that could lead to an accurate and reliable testing procedure that would ensure an adequate method for assessing the capability of activated carbon to remove radioiodine from gas streams within commercial nuclear power plants. The NRC/INEL Activated Carbon Testing Program has conducted formal and informal interlaboratory comparisons to identify problems with the test method and its application and to assess the effectiveness of changes to procedures and equipment voluntarily implemented by commercial laboratories to mitigate the disparity of test results. The results of the first formal NRC/INEL Interlaboratory Comparison (IC) essentially verified the CONAGT round-robin results despite the use of a detailed test protocol. This data indicated that many of the participating laboratories probably had been operating outside the ASTM specifications for relative humidity (RH) and flow. In addition, this process provided information which was used to modify the testing protocol employed for the second NRC/INEL Interlaboratory Comparison (IC-2) to make it more rugged and reliable. These changes to the protocol together with the results of INEL sensitivity testing are the basis for the recommendations presented

  2. International cooperative effort to establish dosimetry standardization for radiation processing

    International Nuclear Information System (INIS)

    Farrar, H. IV.

    1989-01-01

    Radiation processing is a rapidly developing technology with numerous applications in food treatment, sterilization, and polymer modification. The effectiveness of the process depends, however, on the proper application of dose and its measurement. These aspects are being considered by a wide group of experts from around the world who have joined together to write a comprehensive set of standards for dosimetry for radiation processing. Originally formed in 1984 to develop standards for food processing dosimetry, the group has now expanded into a full subcommittee of the American Society for Testing and Materials (ASTM), with 97 members from 19 countries. The scope of the standards now includes dosimetry for all forms of radiation processing. The group has now completed and published four standards, and is working on an additional seven. Three are specifically for food applications and the others are for all radiation applications, including food processing. Together, this set of standards will specify acceptable guidelines and methods for accomplishing the required irradiation treatment, and will be available for adoption by national regulatory agencies in their procedures and protocols. 1 tab

  3. 25 CFR 36.43 - Standard XVI-Student activities.

    Science.gov (United States)

    2010-04-01

    ... § 36.43 Standard XVI—Student activities. All schools shall provide and maintain a well-balanced student..., and planned types of fund-raising activities. (c) School may participate in interscholastic sports and... sanctioned by the school. (g) All student activities involved only in fund raising are required to establish...

  4. Designing cathodic protection systems for marine structures and vehicles. ASTM special technical publication 1370

    Energy Technology Data Exchange (ETDEWEB)

    Hack, H.P. [ed.

    1999-07-01

    Cathodic protection is an important method of protecting structures and ships from the corrosive effects of seawater. Poor designs can be far more costly to implement than optimal designs, Improper design can cause overprotection, with resulting paint blistering and accelerated corrosion of some alloys, underprotection, with resultant structure corrosion, or stray current corrosion of nearby structures. The first ASTM symposium specifically aimed at cathodic protection in seawater was intended to compile all the criteria and philosophy for designing both sacrificial and impressed current cathodic protection systems for structures and vehicles in seawater. The papers which are included in this STP are significant in that they summarize the major seawater cathodic protection system design philosophies. Papers have been processed separately for inclusion on the database.

  5. 78 FR 73415 - Safety Standard for Hand-Held Infant Carriers

    Science.gov (United States)

    2013-12-06

    ... modifications to the ASTM test procedure set forth in ASTM F2050-12 so that the test produces more repeatable... skills necessary for the preparation of reports or records; and a description of the steps the agency has... the Rule on Small Business There are at least 47 firms currently known to be marketing hand- held...

  6. Standards development for fiber optic spectroscopic components for adverse environments

    Science.gov (United States)

    Saggese, Steven J.; Greenwell, Roger A.

    1994-09-01

    Optical fiber sensors are finding wider use in all types of applications involving adverse environments, including exposure to radiation. In order to effectively characterize and evaluate the performance of a fiber sensor system for a radiation environment, such as within a nuclear power plant or in a radioactive waste storage/disposal facility, it is beneficial to develop standard test procedures. Science & Engineering Associates (SEA) has developed two such procedures for the American Society for Testing and Materials (ASTM) which address the testing of optical fibers for remote Raman spectroscopic and broadband sensor applications in a steady state radiation environment.

  7. DOE technical standards list: Directory of DOE and contractor personnel involved in non-government standards activities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-05-01

    The body of this document contains a listing of DOE employees and DOE contractors who have submitted form DOE F 1300.2, Record of Non-Government Standards Activity, which is attached to the end of this document. Additional names were added from rosters supplied by non-Government standards bodies. The committees or governing bodies in which the person participates is listed after each name. An asterisk preceding the committee notation indicates that the person has identified himself or herself as the DOE representative on that committee. Appendices to this document are also provided to sort the information by the parent employment organization, by non-Government standards activity, and by the proper names of the non-Government standards organizations and committees. DOE employees and contractors listed in this technical standards list are those recorded as of May 1, 1999.

  8. Determination of the sensitization of two coatings by steel welding 308l by the EPR-Dl and Astm A-262 practice A techniques; Determinacion de la sensibilizacion de dos revestimientos por soldadura de acero 308L por las tecnicas EPR-DL y ASTM A-262 practica A

    Energy Technology Data Exchange (ETDEWEB)

    Arganis J, C. R.; Zenteno S, J. C.; Robles F, J. L.; Rodriguez M, E.; Vazquez P, A., E-mail: carlos.arganis@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2014-10-15

    A stainless steel 308l coating was deposited by the shielded metal arc welding (SMAW) on steel A36 with a thickness of 4.726 mm in three layers. The sensitization was measured with the technique of Electrochemical Potentiodynamic Reactivation of Double-loop (EPR-Dl), using a portable cell and other of conventional window. The standard Astm A-262, practice A was used to verify the sensitization values. Two samples were used, a welding on a plate of 323 x 172 x 76.2 mm and the second welding on the end of a plate of 12.7 mm of thickness and 280 mm of longitude, with a post-welding process with gas tungsten arc welding (GTAW) with electrode ERNiCr{sub 3} and a process SMAW with electrode ENICRFe{sub 3}. The coating on the plate showed low values of sensitization grade (DOS) in all the points, indicating a very quick heat extraction and an inter dendritic structure type step. The second sample presented DOS values that are related with a structure of low sensitization and the influence of the heat of the post-welding process and a structure of recrystallized grains. (Author)

  9. Fitting psychometric functions using a fixed-slope parameter: an advanced alternative for estimating odor thresholds with data generated by ASTM E679.

    Science.gov (United States)

    Peng, Mei; Jaeger, Sara R; Hautus, Michael J

    2014-03-01

    Psychometric functions are predominately used for estimating detection thresholds in vision and audition. However, the requirement of large data quantities for fitting psychometric functions (>30 replications) reduces their suitability in olfactory studies because olfactory response data are often limited (ASTM) E679. The slope parameter of the individual-judge psychometric function is fixed to be the same as that of the group function; the same-shaped symmetrical sigmoid function is fitted only using the intercept. This study evaluated the proposed method by comparing it with 2 available methods. Comparison to conventional psychometric functions (fitted slope and intercept) indicated that the assumption of a fixed slope did not compromise precision of the threshold estimates. No systematic difference was obtained between the proposed method and the ASTM method in terms of group threshold estimates or threshold distributions, but there were changes in the rank, by threshold, of judges in the group. Overall, the fixed-slope psychometric function is recommended for obtaining relatively reliable individual threshold estimates when the quantity of data is limited.

  10. Hardness optimization of boride diffusion layer on Astm F-75 alloy using response surface methodology

    Energy Technology Data Exchange (ETDEWEB)

    Arguelles O, J. L.; Corona R, M. A. [Universidad Autonoma de San Luis Potosi, Doctorado Institucional en Ingenieria y Ciencia de Materiales, San Luis Potosi 78000, SLP (Mexico); Marquez H, A.; Saldana R, A. L.; Saldana R, A. [Universidad de Guanajuato, Ingenieria Mecanica Agricola DICIVA, Irapuato, Guanajuato 36500 (Mexico); Moreno P, J., E-mail: amarquez@ugto.mx [Universidad de Guanajuato, Departamento de Minas, Metalurgia y Geologia, Ex-Hacienda San Matias s/n, Guanajuato, Guanajuato 36020 (Mexico)

    2017-11-01

    In this study, the Response Surface Methodology (Rsm) and Central Composite Design (Ccd) were used to optimize the hardness of boride diffusion layer on Astm F-75 alloy (also called Haynes alloy). A boronizing thermochemical treatment was carried out at different temperatures and for different time periods. Hardness tests were conducted. The boride diffusion layer was verified by the X-ray diffraction (XRD) analysis indicating the formation of Co B, Co{sub 2}B, Cr B and Mo{sub 2}B phases. An optimal hardness of 3139.7 Hv was obtained for the samples subjected to the boriding process for a duration of 6.86 h at 802.4 degrees Celsius. (Author)

  11. A trial fabrication of activity standard surface sources and positional standard surface sources for an imaging plate system

    International Nuclear Information System (INIS)

    Sato, Yasushi; Hino, Yoshio; Yamada, Takahiro; Matsumoto, Mikio

    2003-01-01

    An imaging plate system can detect low level activity, but quantitative analysis is difficult because there are no adequate standard surface sources. A new fabrication method was developed for standard surface sources by printing on a sheet of paper using an ink-jet printer with inks in which a radioactive material was mixed. The fabricated standard surface sources had high uniformity, high positional resolution arbitrary shapes and a broad intensity range. The standard sources were used for measurement of surface activity as an application. (H. Yokoo)

  12. ASTM F1717 standard for the preclinical evaluation of posterior spinal fixators: can we improve it?

    Science.gov (United States)

    La Barbera, Luigi; Galbusera, Fabio; Villa, Tomaso; Costa, Francesco; Wilke, Hans-Joachim

    2014-10-01

    Preclinical evaluation of spinal implants is a necessary step to ensure their reliability and safety before implantation. The American Society for Testing and Materials reapproved F1717 standard for the assessment of mechanical properties of posterior spinal fixators, which simulates a vertebrectomy model and recommends mimicking vertebral bodies using polyethylene blocks. This set-up should represent the clinical use, but available data in the literature are few. Anatomical parameters depending on the spinal level were compared to published data or measurements on biplanar stereoradiography on 13 patients. Other mechanical variables, describing implant design were considered, and all parameters were investigated using a numerical parametric finite element model. Stress values were calculated by considering either the combination of the average values for each parameter or their worst-case combination depending on the spinal level. The standard set-up represents quite well the anatomy of an instrumented average thoracolumbar segment. The stress on the pedicular screw is significantly influenced by the lever arm of the applied load, the unsupported screw length, the position of the centre of rotation of the functional spine unit and the pedicular inclination with respect to the sagittal plane. The worst-case combination of parameters demonstrates that devices implanted below T5 could potentially undergo higher stresses than those described in the standard suggestions (maximum increase of 22.2% at L1). We propose to revise F1717 in order to describe the anatomical worst case condition we found at L1 level: this will guarantee higher safety of the implant for a wider population of patients. © IMechE 2014.

  13. On-Board Monitoring of Engine Oil

    Science.gov (United States)

    2011-04-01

    methods involve potentiometric and colorimetric titrations , respectively. For both tests, a titration solvent is prepared and added to the oil. The...ASTM D 2896 and ASTM D 4739 [17]. Both methods involve potentiometric titrations . ASTM D 2896 uses a stronger acid and more polar solvent than ASTM D...Petroleum Products by Potentiometric Titration ASTM D 4739 Standard Test Method for Base Number Determination by Potentiometric Titration Gas

  14. International cooperative effort to establish dosimetry standardization for radiation processing

    International Nuclear Information System (INIS)

    Farrar, Harry IV

    1990-01-01

    Radiation processing is a rapidly developing technology with numerous applications in food treatment, sterilization, and polymer modification. The effectiveness of the process depends, however, on the proper application of dose and its measurement. These aspects are being considered by a wide group of experts from around the world who have joined together to write a comprehensive set of standards for dosimetry for radiation processing. Originally formed in 1984 to develop standards for food processing dosimetry, the group has now expanded into a full subcommittee of the American Society for Testing and Materials (ASTM), with 97 members from 19 countries. The scope of the standards now includes dosimetry for all forms and applications of radiation processing. To date, the group has completed and published four standards, and is working on an additional seven. Three are specifically for food applications and the others are for all radiation applications, including food processing. Together, this set of standards will specify acceptable guidelines and methods for accomplishing the required irradiation treatment. This set will be available for adoption by national regulatory agencies or other standards-setting organizations for their procedures and protocols. (author)

  15. 40 CFR 80.580 - What are the sampling and testing methods for sulfur?

    Science.gov (United States)

    2010-07-01

    ... [email protected] from the ASTM Web site of http://www.astm.org. (i) ASTM standard method D2622-05 (“ASTM... methods for sulfur? 80.580 Section 80.580 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... the sampling and testing methods for sulfur? The sulfur content of diesel fuel and diesel fuel...

  16. Geometric investigation of a gaming active device

    Science.gov (United States)

    Menna, Fabio; Remondino, Fabio; Battisti, Roberto; Nocerino, Erica

    2011-07-01

    3D imaging systems are widely available and used for surveying, modeling and entertainment applications, but clear statements regarding their characteristics, performances and limitations are still missing. The VDI/VDE and the ASTME57 committees are trying to set some standards but the commercial market is not reacting properly. Since many new users are approaching these 3D recording methodologies, clear statements and information clarifying if a package or system satisfies certain requirements before investing are fundamental for those users who are not really familiar with these technologies. Recently small and portable consumer-grade active sensors came on the market, like TOF rangeimaging cameras or low-cost triangulation-based range sensor. A quite interesting active system was produced by PrimeSense and launched on the market thanks to the Microsoft Xbox project with the name of Kinect. The article reports the geometric investigation of the Kinect active sensors, considering its measurement performances, the accuracy of the retrieved range data and the possibility to use it for 3D modeling application.

  17. Characterisation of middle-distillates by comprehensive two-dimensional gas chromatography (GC x GC): A powerful alternative for performing various standard analysis of middle-distillates.

    Science.gov (United States)

    Vendeuvre, Colombe; Ruiz-Guerrero, Rosario; Bertoncini, Fabrice; Duval, Laurent; Thiébaut, Didier; Hennion, Marie-Claire

    2005-09-09

    The detailed characterisation of middle distillates is essential for a better understanding of reactions involved in refining process. Owing to higher resolution power and enhanced sensitivity, comprehensive two-dimensional gas chromatography (GC x GC) is a powerful tool for improving characterisation of petroleum samples. The aim of this paper is to compare GC x GC and various ASTM methods -- gas chromatography (GC), liquid chromatography (LC) and mass spectrometry (MS) -- for group type separation and detailed hydrocarbon analysis. Best features of GC x GC are demonstrated and compared to these techniques in terms of cost, time consumption and accuracy. In particular, a new approach of simulated distillation (SimDis-GC x GC) is proposed: compared to the standard method ASTM D2887 it gives unequal information for better understanding of conversion process.

  18. Localized corrosion evaluation of the ASTM F139 stainless steel marked by laser using scanning vibrating electrode technique, X-ray photoelectron spectroscopy and Mott–Schottky techniques

    International Nuclear Information System (INIS)

    Pieretti, Eurico F.; Manhabosco, Sara M.; Dick, Luís F.P.; Hinder, Steve; Costa, Isolda

    2014-01-01

    Graphical abstract: SEM image of pits found at the centred marked area, where the laser beam focused twice. - Highlights: • The effect of laser engraving on the corrosion resistance of the ASTM F139 was studied. • Scanning vibrating electrode technique was used to identify the anodic zone. • Laser engraving of austenitic stainless steels produces highly defective surfaces. • Laser engraving causes large chemical modification of the surface. • Pitting nucleates at the interface between laser affected and unaffected areas. - Abstract: The effect of laser engraving on the corrosion resistance of ASTM F139 stainless steel (SS) has been investigated by electrochemical techniques. The nucleation of localized corrosion on this biomaterial was evaluated by scanning vibrating electrode technique (SVET) in a phosphate buffered saline solution (PBS) of pH 7.4. The Mott–Schottky approach was used to determine the electronic properties of the passive film, also chemically characterized by X-ray photoelectron spectroscopy (XPS). SVET allowed the identification of the anodic zones on the surface of the SS marked by laser technique that were associated with the heat-affected areas. Metallic drops solidified on the laser marked surface dissolved actively at OCP and favoured the nucleation of crevice corrosion, while at the pitting potential, pits nucleate preferentially on the laser marks. XPS results showed that laser engraving caused large chemical modification of the surface. Mott–Schottky results indicated a more defective oxide layer with a larger number of donors on the laser marked surface comparatively to that without marks

  19. Determination of CTOD C in Fibre Metal Laminates by ASTM and Schwalbe Methods

    Directory of Open Access Journals (Sweden)

    E.M. Castrodeza

    2002-06-01

    Full Text Available Fibre Metal Laminates (FMLs have arisen as a demand of the aeronautical industry to use thin sheets with high resistance to fatigue crack growth, high damage tolerance, corrosion resistance and high specific strength. Considering these requirements, FMLs are an advantageous choice when compared to metal alloys currently used. In order to employ FMLs in aircraft structures, designers must hold a deep knowledge of a wide set of their properties including fracture toughness. The aim of this work was to evaluate the available methodologies to measure fracture toughness at instability (CTOD C in unidirectional fibre metal laminates reinforced with aramid fibres (ARALL®. To achieve this, tests were performed to obtain traditional and Schwalbe CTODs by using experimental ASTM based techniques, especially adapted to these laminates. Results achieved point out that Schwalbe method is more appropriate and also that there are differences between both CTOD parameters.

  20. Biodiesel Fuel Quality and the ASTM Biodiesel Standard

    Science.gov (United States)

    Biodiesel is usually produced from vegetable oils, animal fats and used cooking oils with alternative feedstocks such as algae receiving increasing interest. The transesterification reaction which produces biodiesel also produces glycerol and proceeds stepwise via mono- and diacylglycerol intermedi...

  1. Sequestration Coating Performance Requirements for Mitigation of Contamination from a Radiological Dispersion Device

    International Nuclear Information System (INIS)

    Drake, J.

    2009-01-01

    Immediate action would be necessary to minimize the effects of a radiological 'dirty bomb' detonation in a major city. After a dirty bomb has been detonated, vehicular and pedestrian traffic, as well as weather effects, would increase the spread of loose contamination, making control and recovery more difficult and costly. While contaminant migration and chemical binding into surface materials can be relatively rapid, the immediate treatment of surfaces with large quantities of an appropriate compound could alleviate much of the difficulty in decontamination. The EPA's National Homeland Security Research Center (NHSRC), in collaboration with ASTM International, is currently developing performance standards for materials which could be applied to exterior surfaces contaminated by an RDD to mitigate the spread and migration of radioactive contamination. These performance standards are being promulgated via an ASTM Standard Specification to be published by ASTM International. Test methods will be developed to determine if candidate coatings meet the performance requirements stipulated in the ASTM performance standard. These test methods will be adapted from existing standard methods, or will be devised through laboratory research. The final set of test methods will be codified in an ASTM or other standard test method. The principal market for products described in the ASTM performance standard would be federal, state and local government emergency responders and response planners, decontamination service providers and those whose interests include protection and recovery of real estate potentially at risk from radiological terrorism. (authors)

  2. DOE technical standards list: Directory of DOE and contractor personnel involved in non-government standards activities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-08-01

    The body of this document contains a listing of DOE employees and DOE contractors who have submitted form DOE F 1300.2, Record of Non-Government Standards Activity, which is attached to the end of this document and to DOE Order 1300.2A. Additional names were added from rosters supplied by non-Government standards bodies. The committees or governing bodies in which the person participates is listed after each name. An asterisk preceding the committee notation indicates that the person has identified himself or herself as the DOE representative on that committee. Appendices to this document are also provided to sort the information by the parent employment organization, by non-Government standards activity, and by the proper names of the non-Government standards organizations and committees. DOE employees and contractors listed in this TSL are those recorded as of July 1, 1996.

  3. Standard practice for leaks using bubble emission techniques

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This practice describes accepted procedures for and factors that influence laboratory immersion corrosion tests, particularly mass loss tests. These factors include specimen preparation, apparatus, test conditions, methods of cleaning specimens, evaluation of results, and calculation and reporting of corrosion rates. This practice also emphasizes the importance of recording all pertinent data and provides a checklist for reporting test data. Other ASTM procedures for laboratory corrosion tests are tabulated in the Appendix. (Warning-In many cases the corrosion product on the reactive metals titanium and zirconium is a hard and tightly bonded oxide that defies removal by chemical or ordinary mechanical means. In many such cases, corrosion rates are established by mass gain rather than mass loss.) 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. This standard does not purport to address all of the safety concerns, if any, assoc...

  4. Sensitivities of a Standard Test Method for the Determination of the pHe of Bioethanol and Suggestions for Improvement

    Directory of Open Access Journals (Sweden)

    Paul J. Brewer

    2010-11-01

    Full Text Available An assessment of the sensitivities of the critical parameters in the ASTM D6423 documentary standard method for the measurement of pHe in (bioethanol has been undertaken. Repeatability of measurements made using the same glass electrode and reproducibility between different glass electrodes have been identified as the main contributors to the uncertainty of the values produced. Strategies to reduce the uncertainty of the measurement have been identified and tested. Both increasing the time after which the pHe measurement is made following immersion in the sample, and rinsing the glass electrode with ethanol prior to immersion in the sample, have been shown to be effective in reducing the uncertainty of the numerical value produced. However, it is acknowledged that the values produced using these modified approaches may not be directly compared with those obtained using the documentary ASTM method since pHe is defined operationally by the process used to measure it.

  5. Characterization of ASTM A335 P92 steel in continuous cooling cycles

    International Nuclear Information System (INIS)

    Xaubet, M. N.; Danón, C. A.; Ramos, C. P.

    2013-01-01

    The operating conditions demanded by Generation IV reactors include high temperatures, higher radiation doses and highly corrosive environments. Among the structural materials proposed both for in-core and out-of-core applications, elevated-temperature P91/P92 ferritic/martensitic steels have been considered. This work studies the transformation behavior and microstructural evolution of ASTM A335 P92 steel in continuous cooling cycles (CCT). The material was austenized at 1050 ºC and afterwards cooled down at controlled rates (300, 50 and 15 ºC/h). The determination and characterization of the phases present in the samples was performed by optical microscopy, field emission scanning electron microscopy, Mössbauer spectroscopy and X-ray diffraction. Samples whose cooling rates were on the limits of the studied range (300 and 15 ºC/h) presented completely martensitic and completely ferritic structures, respectively. The sample cooled down at intermediate rate exhibited, though, a mixed structure of martensite and ferrite. Second-phase precipitation has also been observed in all the samples. (author)

  6. Standard methods for sampling and sample preparation for gamma spectroscopy

    International Nuclear Information System (INIS)

    Taskaeva, M.; Taskaev, E.; Nikolov, P.

    1993-01-01

    The strategy for sampling and sample preparation is outlined: necessary number of samples; analysis and treatment of the results received; quantity of the analysed material according to the radionuclide concentrations and analytical methods; the minimal quantity and kind of the data needed for making final conclusions and decisions on the base of the results received. This strategy was tested in gamma spectroscopic analysis of radionuclide contamination of the region of Eleshnitsa Uranium Mines. The water samples was taken and stored according to the ASTM D 3370-82. The general sampling procedures were in conformity with the recommendations of ISO 5667. The radionuclides was concentrated by coprecipitation with iron hydroxide and ion exchange. The sampling of soil samples complied with the rules of ASTM C 998, and their sample preparation - with ASTM C 999. After preparation the samples were sealed hermetically and measured. (author)

  7. 75 FR 43107 - Revocation of Requirements for Full-Size Baby Cribs and Non-Full-Size Baby Cribs

    Science.gov (United States)

    2010-07-23

    ...] Revocation of Requirements for Full-Size Baby Cribs and Non-Full- Size Baby Cribs AGENCY: Consumer Product... standards, and include ASTM F 1169-10, ``Standard Consumer Safety Specification for Full-Size Baby Cribs,'' and ASTM F 406-10, ``Standard Consumer Safety Specification for Non-Full-Size Baby Cribs/Play Yards...

  8. Measuring the activity of BioBrick promoters using an in vivo reference standard

    Directory of Open Access Journals (Sweden)

    Kelly Jason R

    2009-03-01

    Full Text Available Abstract Background The engineering of many-component, synthetic biological systems is being made easier by the development of collections of reusable, standard biological parts. However, the complexity of biology makes it difficult to predict the extent to which such efforts will succeed. As a first practical example, the Registry of Standard Biological Parts started at MIT now maintains and distributes thousands of BioBrick™ standard biological parts. However, BioBrick parts are only standardized in terms of how individual parts are physically assembled into multi-component systems, and most parts remain uncharacterized. Standardized tools, techniques, and units of measurement are needed to facilitate the characterization and reuse of parts by independent researchers across many laboratories. Results We found that the absolute activity of BioBrick promoters varies across experimental conditions and measurement instruments. We choose one promoter (BBa_J23101 to serve as an in vivo reference standard for promoter activity. We demonstrated that, by measuring the activity of promoters relative to BBa_J23101, we could reduce variation in reported promoter activity due to differences in test conditions and measurement instruments by ~50%. We defined a Relative Promoter Unit (RPU in order to report promoter characterization data in compatible units and developed a measurement kit so that researchers might more easily adopt RPU as a standard unit for reporting promoter activity. We distributed a set of test promoters to multiple labs and found good agreement in the reported relative activities of promoters so measured. We also characterized the relative activities of a reference collection of BioBrick promoters in order to further support adoption of RPU-based measurement standards. Conclusion Relative activity measurements based on an in vivoreference standard enables improved measurement of promoter activity given variation in measurement

  9. The fatigue-crack propagation behavior of ASTM A533-B steel tested in vacuo at LWR operating temperatures

    International Nuclear Information System (INIS)

    James, L.A.

    1987-01-01

    The fatigue-crack propagation (FCP) behavior of ASTM A533-B-1 steel was characterized in vacuo at 288 0 C. Tests were conducted at two stress ratios: R = 0.05 and R = 0.7. Results of these tests were compared with results from previous studies for the same type of steel tested in an air environment, and FCP rates in vacuo were generally lower than those in air. Stress ratio effects in vacuo were not as great as those in air, and both stress ratio effects and environmental effects are discussed from the standpoint of crack closure concepts

  10. Effects of Water Hardness on Spray Droplet Size Under Aerial Application Conditions

    Science.gov (United States)

    2008-01-01

    Nonimaging Light‐Scattering Instruments (ASTM, 2003). Table 1. Spray formulations for water hardness levels. Hardness (ppm) Tank, L (gal) Kocide, kg (lb...characteristics in a spray using optical nonimaging light‐scattering instruments. W. Conshohocken, Pa.: ASTM Intl. ASTM. 2004. E1620‐97. Standard

  11. Comparative analysis of international standards for the fatigue testing of posterior spinal fixation systems: the importance of preload in ISO 12189.

    Science.gov (United States)

    La Barbera, Luigi; Ottardi, Claudia; Villa, Tomaso

    2015-10-01

    Preclinical evaluation of the mechanical reliability of fixation devices is a mandatory activity before their introduction into market. There are two standardized protocols for preclinical testing of spinal implants. The American Society for Testing Materials (ASTM) recommends the F1717 standard, which describes a vertebrectomy condition that is relatively simple to implement, whereas the International Organization for Standardization (ISO) suggests the 12189 standard, which describes a more complex physiological anterior support-based setup. Moreover, ASTM F1717 is nowadays well established, whereas ISO 12189 has received little attention: A few studies tried to accurately describe the ISO experimental procedure through numeric models, but these studies totally neglect the recommended precompression step. This study aimed to build up a reliable, validated numeric model capable of describing the stress on the rods of a spinal fixator assembled according to ISO 12189 standard procedure. Such a model would more adequately represent the in vitro testing condition. This study used finite element (FE) simulations and experimental validation testing. An FE model of the ISO setup was built to calculate the stress on the rods. Simulation was validated by comparison with experimental strain gauges measurements. The same fixator has been previously virtually mounted in an L2-L4 FE model of the lumbar spine, and stresses in the rods were calculated when the spine was subjected to physiological forces and moments. The comparison between the FE predictions and experimental measurements is in good agreement, thus confirming the suitability of the FE method to evaluate the stresses in the device. The initial precompression induces a significant extension of the assembled construct. As the applied load increases, the initial extension is gradually compensated, so that at peak load the rods are bent in flexion: The final stress value predicted is thus reduced to about 50%, if

  12. Determination of the sensitization of two coatings by steel welding 308l by the EPR-Dl and Astm A-262 practice A techniques

    International Nuclear Information System (INIS)

    Arganis J, C. R.; Zenteno S, J. C.; Robles F, J. L.; Rodriguez M, E.; Vazquez P, A.

    2014-10-01

    A stainless steel 308l coating was deposited by the shielded metal arc welding (SMAW) on steel A36 with a thickness of 4.726 mm in three layers. The sensitization was measured with the technique of Electrochemical Potentiodynamic Reactivation of Double-loop (EPR-Dl), using a portable cell and other of conventional window. The standard Astm A-262, practice A was used to verify the sensitization values. Two samples were used, a welding on a plate of 323 x 172 x 76.2 mm and the second welding on the end of a plate of 12.7 mm of thickness and 280 mm of longitude, with a post-welding process with gas tungsten arc welding (GTAW) with electrode ERNiCr 3 and a process SMAW with electrode ENICRFe 3 . The coating on the plate showed low values of sensitization grade (DOS) in all the points, indicating a very quick heat extraction and an inter dendritic structure type step. The second sample presented DOS values that are related with a structure of low sensitization and the influence of the heat of the post-welding process and a structure of recrystallized grains. (Author)

  13. Anti-inflammatory and antinociceptive activities of Phyllanthus niruri spray-dried standardized extract

    Directory of Open Access Journals (Sweden)

    Cínthia R. C. Porto

    2013-02-01

    Full Text Available Phyllanthus niruri L., Euphorbiaceae, spray-dried standardized extract was studied for its anti-inflammatory and antinociceptive activities in adult albino rats and mice. The anti-inflammatory effect of spray-dried standardized extract was observed in carrageenan-induced paw edema and thioglycolate-induced leukocyte migration, while antinociceptive effects were observed using Randall & Selitto, tail flick, and hot plate tests. This study showed that intraperitoneal spray-dried standardized extract at 100, 200, 800, or 1600 mg/kg reduced the vascular response in the inflammatory process of paw edema induced by 1% carrageenan. Oral spray-dried standardized extract at 100 or 200 mg/kg inhibited leukocyte migration to the site of inflammation induced by 3% thioglycolate. In rats, at 100 and 200 mg/kg intraperitoneally, the extract exhibited a marked peripheral analgesic effect in a Randall & Selitto assay and showed significant central analgesic activity in a hot plate and tail flick assay. In conclusion, this study suggested that Phyllanthus niruri spray-dried standardized extract has potent inflammatory and antinociceptive activities and that these activities are not modified by standard drying process, making it feasible to use the dry extract standardized to obtain a phytotherapic preparation and thus validating its use for the treatment of pain and inflammation disorders.

  14. Multielement analysis of biological standards by neutron activation analysis

    International Nuclear Information System (INIS)

    Nadkarni, R.A.

    1977-01-01

    Up to 28 elements were determined in two IAEA standards: Animal Muscle H4 and Fish Soluble A 6/74, and three NBS standards: Spinach: SRM-1570, Tomato Leaves: SRM-1573 and Pine Needles: SRM-1575 by instrumental neutron-activation analysis. Seven noble metals were determined in two NBS standards: Coal: SRM-1632 and Coal Fly Ash: SRM-1633 by radiochemical procedure while 11 rare earth elements were determined in NBS standard Orchard Leaves: SRM-1571 by instrumental neutron-activation analysis. The results are in good agreement with the certified and/or literature data where available. The irradiations were performed at the Cornell TRIGA Mark II nuclear reactor at a thermal neutron flux of 1-3x10 12 ncm -2 sec -1 . The short-lived species were determined after a 2-minute irradiation in the pneumatic rabbit tube, and the longer-lived species after an 8-hour irradiation in the central thimble facility. The standards and samples were counted on coaxial 56-cm 3 Ge(Li) detector. The system resolution was 1.96 keV (FWHM) with a peak to Compton ratio of 37:1 and counting efficiency of 13%, all compared to the 1.332 MeV photopeak of Co-60. (T.I.)

  15. [Comparison of susceptibility artifacts generated by microchips with different geometry at 1.5 Tesla magnet resonance imaging. A phantom pilot study referring to the ASTM standard test method F2119-07].

    Science.gov (United States)

    Dengg, S; Kneissl, S

    2013-01-01

    Ferromagnetic material in microchips, used for animal identification, causes local signal increase, signal void or distortion (susceptibility artifact) on MR images. To measure the impact of microchip geometry on the artifact's size, an MRI phantom study was performed. Microchips of the labels Datamars®, Euro-I.D.® and Planet-ID® (n  =  15) were placed consecutively in a phantom and examined with respect to the ASTM Standard Test Method F2119-07 using spin echo (TR 500 ms, TE 20 ms), gradient echo (TR 300 ms, TE 15 ms, flip angel 30°) and otherwise constant imaging parameters (slice thickness 3 mm, field of view 250 x 250 mm, acquisition matrix 256 x 256 pixel, bandwidth 32 kHz) at 1.5 Tesla. Image acquisition was undertaken with a microchip positioned in the x- and z-direction and in each case with a phase-encoding direction in the y- and z-direction. The artifact size was determined with a) a measurement according to the test method F2119-07 using a homogeneous point operation, b) signal intensity measurement according to Matsuura et al. and c) pixel counts in the artifact according to Port and Pomper. There was a significant difference in artifact size between the three microchips tested (Wilcoxon p = 0.032). A two- to three-fold increase in microchip volume generated an up to 76% larger artifact, depending on the sequence type, phase-encoding direction and chip position to B0. The smaller the microchip geometry, the less is the susceptibility artifact. Spin echoes (SE) generated smaller artifacts than gradient echoes (GE). In relation to the spatial measurement of the artifact, the switch in phase-encoding direction had less influence on the artifact size in GE- than in SE-sequences. However, the artifact shape and direction of SE-sequences can be changed by altering the phase. The artifact size, caused by the microchip, plays a major clinical role in the evaluation of MRI from the head, shoulder and neck regions.

  16. 29 CFR 1918.104 - Foot protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Foot protection. 1918.104 Section 1918.104 Labor... following consensus standards: (i) ASTM F-2412-2005, “Standard Test Methods for Foot Protection,” and ASTM F... footwear that is constructed in accordance with one of the above consensus standards will be deemed to be...

  17. 40 CFR 89.6 - Reference materials.

    Science.gov (United States)

    2010-07-01

    ... Distillation of Petroleum Products at Atmospheric Pressure” Appendix A to Subpart D. ASTM D93-97: “Standard... D287-92: “Standard Test Method for API Gravity of Crude Petroleum and Petroleum Products” (Hydrometer...: “Standard Test Method for Cetane Number of Diesel Fuel Oil” Appendix A to Subpart D. ASTM D1319-98...

  18. Spontaneous ignition in afterburner segment tests at an inlet temperature of 1240 K and a pressure of 1 atmosphere with ASTM jet-A fuel

    Science.gov (United States)

    Schultz, D. F.; Branstetter, J. R.

    1973-01-01

    A brief testing program was undertaken to determine if spontaneous ignition and stable combustion could be obtained in a jet engine afterburning operating with an inlet temperature of 1240 K and a pressure of 1 atmosphere with ASTM Jet-A fuel. Spontaneous ignition with 100-percent combustion efficiency and stable burning was obtained using water-cooled fuel spraybars as flameholders.

  19. Grazing incidence synchrotron X-ray diffraction and Moessbauer spectroscopy analyses of plasma nitrided ASTM F138 stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Danilo Olzon Dionysio de; Ardisson, Jose Domingos, E-mail: dolzon@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Silva, Edilaine Honorio [Studiecentrum voor Kernenergie (Belgium); Olzon-Dionysio, Maristela; Souza, Sylvio Dionysio de; Fabris, Jose Domingos [Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM), Diamantina, MG (Brazil); Martinez, L.G. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2016-07-01

    Full text: systematic investigation of samples of plasma-nitriding austenitic stainless steels ASTM F138 and AISI 316L is reported. The surface treatment of the steels through plasma-nitriding was used to improve further the hardness, wear and corrosion resistance of these stainless steels. The resulting layered crystallographic structure actually corresponds to several phases with close cell parameters, making their identification and quantification a real experimental challenge. The ASTM F138 and AISI 316L stainless steel disks were plasma nitrided for 4 h at 400 deg C in a 80% H{sub 2} -20% N2 atmosphere at 6 torr, using plasma current frequencies between 6 and 100 kHz. Data of Moessbauer (CEMS and CXMS) and grazing incidence synchrotron X-ray diffraction (XRD-SR) were systematically collected. The nitrided layer thickness were not in general influenced by the plasma frequency, except at 12 kHz, which produced a layer thickness of approximately 8.0 mm, being in average 40% thicker than for the other samples. CXMS and CEMS Moessbauer spectra for this 12 kHz-sample show a much more pronounced magnetic resonance lines than for the other samples. The Fe{sub 4}N phase presents a single magnetic hyperfine interaction; the other two (Fe{sub 2-3}N and the expanded austenite) present both paramagnetic and magnetic components, even though their hyperfine parameters may not be safely separated. We also present the results of XRD-SR that were probed at several depths. The data from these techniques may be consistently correlated and this leads to an improved model to explain the structure of the nitrided layers. (author)

  20. Evaluation of the EPA Drift Reduction Technology (DRT) Low-Speed Wind Tunnel Protocol

    Science.gov (United States)

    2009-01-01

    Characteristics in a Spray Using Optical Nonimaging Light-Scattering by ASTM Int’l (all rights reserved); Thu May 7 10:08:26 EDT 2009 ed/printed by itz...Spray Using Optical Nonimaging Light-Scattering Instruments,” Annual Book of ASTM Standards, ASTM International, West Conshohocken, PA, 2003. 9

  1. 40 CFR 98.254 - Monitoring and QA/QC requirements.

    Science.gov (United States)

    2010-07-01

    ...) Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuels by Bomb Calorimeter (incorporated... methods. (1) ASTM D4809-06 Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuels by Bomb...) Method 18 at 40 CFR part 60, appendix A-6. (2) ASTM D1945-03 Standard Test Method for Analysis of Natural...

  2. Heat treatment evaluation of steel ASTM A-131 grade A by X-Ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira Junior, Francisco; Feio, Luciana Gaspar; Costa, Ednelson Silva; Rodrigues, Lino Alberto Soares; Braga, Eduardo Magalhaes, E-mail: juniorferrer93@gmail.com [Universidade Federal do Pará (UFPA), Belém, PA (Brazil)

    2016-07-01

    Full text: This study evaluates the residual stress of naval steel ASTM A-131 grade A before and after heat treatment. Residual stresses were determined by the technique of X-ray diffraction (XRD). Before heat treatment the residual stress measurements were made at 36 (thirty six) points distributed in a specimen with dimensions of 400 mm long, 200 mm wide and 95 mm thick, then the plate under analysis was brought to the oven for the implementation of heat treatment. To check the performance of the heat treatment, the plate was again subjected to XRD measurements of the same points previously measured in order to compare the residual stresses. As result, there was a reduction of residual stresses with the application of heat treatment. References: [1] COLPAERT, H. Metalografia dos Produtos Siderurgicos Comuns. 4 Edição. Editora Blucher. Saõ Paulo, SP, 2008. [2] HILL, R. Princípios de Metalurgia Física, 1992. (author)

  3. The new ASTM Manual for scrubber linings the evolution of a consensus guide

    International Nuclear Information System (INIS)

    Spires, G.V.; Cavallo, J.R.

    1984-01-01

    Faced with spiraling fuel oil costs, power utilities turned to abundant and inexpensive domestic coal and lignite. Conversions and new units designed to burn solid fossil fuels were pursued at a near crisis pace to get out from under the economic penalties associated with the continued use of oil. Coal contains much more sulfur than oil; EPA limitations on SO 2 necessitated costly flue gas desulfurization (FGD) systems when burning coal. Scrubbed gas presented a particularly corrosive environment in and downstream from the FGD system. Problems which often accompany a new technology were soon evident. Materials and linings initially selected were often seen to be inadequate. Severe and rapid degradation was commonplace. This paper traces the development of the recently published ASTM Manual of Protective Linings From Flue Gas Desulfurization System. The scope of the Manual is outlined and some of the more commonly used FGD lining systems are reviewed. Finally some views on the impact of foreseeable changes in regulations and FGD technology on the use and maintenance of FGD system linings are discussed

  4. Gas chromatographic sulphur speciation in heavy crude oil using a modified standard D5623 method and microfluidic Deans switching.

    Science.gov (United States)

    Heshka, Nicole E; Choy, Joanne M; Chen, Jinwen

    2017-12-29

    A modification to American Society for Testing and Materials (ASTM) method D5623 is proposed to enable successful and repeatable analysis of heavy crude oil samples. A two-dimensional gas chromatography configuration was implemented, with separation of sulphur compounds occurring on two columns. A Deans switch is used to enable heart-cutting of volatile sulphur compounds onto a DB-Sulfur stationary phase, and separation occurs concurrently with the backflushing of the primary column. The use of a sulphur-selective detector increases selectivity, and 22 volatile sulphur species are quantified in less than 15min, which is almost half the time of the original ASTM method. Samples ranging from light distillation cuts to whole crudes (boiling from 100°C to >750°C) were analyzed with minimal sample preparation. The calculated limit of detection was 0.7mg/kg, repeatability was 3% relative standard deviation (RSD), and a linear range of 1-250mg/kg was obtained, with an R 2 value of 0.994 or better, depending on the compound. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  5. 40 CFR 90.7 - Reference materials.

    Science.gov (United States)

    2010-07-01

    .... ASTM D3231-89: Standard Test Method for Phosphorus in Gasoline Appendix A to subpart D, Table 3. ASTM D3606-92: Standard Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation... 770141, Optimization of a Flame Ionization Detector for Determination of Hydrocarbon in Diluted...

  6. Avaliação das propriedades termo-mecânicas de borracha nitrílica após ensaio de compatibilidade de acordo com ASTM D 3455 Thermal-mechanical properties evaluation of nitrilic rubber after compatibility test according to ASTM D 3455

    Directory of Open Access Journals (Sweden)

    Adailze L. Meyer

    2006-01-01

    Full Text Available O copolímero butadieno - acrilonitrila - NBR é comumente aplicado na confecção de gaxetas e anéis de vedação para transformadores elétricos isolados a óleo mineral. Durante o uso esses materiais permanecem em contato com óleo em temperaturas próximas a 90 ºC provocando alterações físicas e químicas no material elastomérico e no óleo. Neste trabalho, estudou-se a variação das propriedades mecânicas do elastômero resultantes do ensaio de compatibilidade (ASTM D 3455[3]. A caracterização mecânica foi realizada por ensaios de resistência a tração, dureza e análise dinâmico-mecânica (DMA. A verificação da estabilidade térmica e a composição do NBR foram obtidas através de análise termogravimétrica (TGA.The copolymer of acrylonitrile and butadiene - NBR is commonly used to manufacture gaskets and seals to be used in electrical transformers insulated by mineral oil. During operation those materials are constantly in contact with oil at temperatures that can reach 90 ºC, causing physical and chemicals changes in both gaskets and oil. In this paper the changes in elastomer mechanical properties after the compatibility test were studied (ASTM D 3455[3]. This characterization was done by tension properties, hardness and dynamical mechanical analysis (DMA. The evaluation of thermal stability and composition of the NBR was carried out through thermogravimetry analysis (TG.

  7. Application of Response Surface Methodology for Modeling of Postweld Heat Treatment Process in a Pressure Vessel Steel ASTM A516 Grade 70.

    Science.gov (United States)

    Peasura, Prachya

    2015-01-01

    This research studied the application of the response surface methodology (RSM) and central composite design (CCD) experiment in mathematical model and optimizes postweld heat treatment (PWHT). The material of study is a pressure vessel steel ASTM A516 grade 70 that is used for gas metal arc welding. PWHT parameters examined in this study included PWHT temperatures and time. The resulting materials were examined using CCD experiment and the RSM to determine the resulting material tensile strength test, observed with optical microscopy and scanning electron microscopy. The experimental results show that using a full quadratic model with the proposed mathematical model is YTS = -285.521 + 15.706X1 + 2.514X2 - 0.004X1(2) - 0.001X2(2) - 0.029X1X2. Tensile strength parameters of PWHT were optimized PWHT time of 5.00 hr and PWHT temperature of 645.75°C. The results show that the PWHT time is the dominant mechanism used to modify the tensile strength compared to the PWHT temperatures. This phenomenon could be explained by the fact that pearlite can contribute to higher tensile strength. Pearlite has an intensity, which results in increased material tensile strength. The research described here can be used as material data on PWHT parameters for an ASTM A516 grade 70 weld.

  8. Provenience studies using neutron activation analysis: the role of standardization

    International Nuclear Information System (INIS)

    Harbottle, G.

    1980-01-01

    This paper covers the historical background of chemical analysis of archaeological artifacts which dates back to 1790 to the first application of neutron activation analysis to archaeological ceramics and goes on to elaborate on the present day status of neutron activation analysis in provenience studies, and the role of standardization. In principle, the concentrations of elements in a neutron-activated specimen can be calculated from an exact knowledge of neutron flux, its intensity, duration and spectral (energy) distribution, plus an exact gamma ray count calibrated for efficiency, corrected for branching rates, etc. However, in practice it is far easier to compare one's unknown to a standard of known or assumed composition. The practice has been for different laboratories to use different standards. With analyses being run in the thousands throughout the world, a great benefit would be derived if analyses could be exchanged among all users and/or generators of data. The emphasis of this paper is on interlaboratory comparability of ceramic data; how far are we from it, what has been proposed in the past to achieve this goal, and what is being proposed. All of this may be summarized under the general heading of Analytical Quality Control - i.e., how to achieve precise and accurate analysis. The author proposes that anyone wishing to analyze archaeological ceramics should simply use his own standard, but attempt to calibrate that standard as nearly as possible to absolute (i.e., accurate) concentration values. The relationship of Analytical Quality Control to provenience location is also examined

  9. Primary activity standardization of {sup 57}Co by sum-peak method

    Energy Technology Data Exchange (ETDEWEB)

    Iwahara, A. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI)/Instituto de Radioprotecao e Dosimetria (IRD)/Comissao Nacional de Energia Nuclear - CNEN, Av. Salvador Allende, s/no. Recreio dos Bandeirantes - CEP 22780-160 Rio de Janeiro (Brazil)], E-mail: iwahara@ird.gov.br; Poledna, R.; Silva, C.J. da; Tauhata, L. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI)/Instituto de Radioprotecao e Dosimetria (IRD)/Comissao Nacional de Energia Nuclear - CNEN, Av. Salvador Allende, s/no. Recreio dos Bandeirantes - CEP 22780-160 Rio de Janeiro (Brazil)

    2009-10-15

    The sum-peak method was applied to standardize a {sup 57}Co solution within the framework of an international comparison organized by International Atomic Energy Agency, in 2008, aimed toward international traceability of activity measurements. A planar germanium detector was used with the sources placed on top of the detector for activity determination measurements. An analytical expression for accidental summing correction was derived and the effect of the germanium characteristic KX-ray escape peak of 112 keV was taken into account. The standard uncertainty associated to the activity concentration value was 0.37% and the result was compared with other measurement methods.

  10. 78 FR 38739 - Standard Format and Content for Post-Shutdown Decommissioning Activities Report

    Science.gov (United States)

    2013-06-27

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0299] Standard Format and Content for Post-Shutdown Decommissioning Activities Report AGENCY: Nuclear Regulatory Commission. ACTION: Regulatory guide; issuance..., ``Standard Format and Content for Post-shutdown Decommissioning Activities Report.'' This guide describes a...

  11. FY 2000 Project of developing international standards for supporting new industries. 'Standardization of multicolor measurement'; 2000 nendo shinki sangyo shiengata kokusai hyojun kaihatsu jigyo seika hokokusho. Multicolor no sokushoku no hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Described herein are the FY 2000 results of the study on and research and development of the testing methods for tones of anisotropic color materials (multi-colors) for proposing the international standard. USA has proposed the triangle colorimetry, based on the results of the visual tests with metallic paints, which is being incorporated in the ASTM standards. Germany seems to adopt the multi-angle colorimetery in the DIN standards. The FY 2000 efforts are directed to measurement of the reflection characteristics of the metallic and pearl-mica samples by a variable-angle spectrophotometer. The solid color and metallic color are being evaluated by a weather resistance tester QUV and outdoor tests, because of the anticipated different mechanisms by which they are aged. The functional test and analysis are also required to correlate the multi-color measurement results with visual evaluation results, and the preliminary tests are conducted to improve skill of the panelists. (NEDO)

  12. Hydrogen embrittlement of ASTM A 203 D nuclear structural steel

    International Nuclear Information System (INIS)

    Chakravartty, J.K.; Prasad, G.E.; Sinha, T.K.; Asundi, M.K.

    1986-01-01

    The influence of hydrogen on the mechanical properties of ASTM A 203 D nuclear structural steel has been studied by tension, bend and delayed-failure tests at room temperature. While the tension tests of hydrogen charged unnotched specimens reveal no change in ultimate strength and ductility, the effect of hydrogen is manifested in notched specimens (tensile and bend) as a decrease in ultimate strength (maximum load in bend test) and ductility; the effect increases with increasing hydrogen content. It is observed that for a given hydrogen concentration, the decrease in bend ductility is remarkably large compared to that in tensile ductility. Hydrogen charging does not cause any delayed-failure upto 200 h under an applied tensile stress, 0.85 times the notch tensile strength. However delayed failure occurs in hydrogen charged bend samples in less than 10 h under an applied bending load of about 0.80 times of the uncharged maximum load. Fractographs of hydrogen charged unnotched specimens show ductile dimple fracture, while those of notched tension and bend specimens under hydrogen-charged conditions show a mixture of ductile dimple and quasi-cleavage cracking. The proportion of quasi-cleavage cracking increases with increasing hydrogen content and this fracture mode is more predominant in bend specimens. The changes in tensile properties and fracture modes can reasonably be explained by existing theories of hydrogen embrittlement. An attempt is made to explain the significant difference in the embrittlement susceptibility of bend and tensile specimens in the light of difference in triaxiality and plastic zone size near the notch tip. (orig.)

  13. Method validation for uranium content analysis using a potentiometer T-90

    International Nuclear Information System (INIS)

    Torowati; Ngatijo; Rahmiati

    2016-01-01

    An experimental method validation has been conducted for uranium content analysis using Potentiometer T-90. The method validation experiment was performed in the quality control laboratory of Experiment Fuel Element Installation, PTBBN - BATAN. The objective is to determine the level of precision and accuracy of analytical results for uranium analysis referring to the latest American Standard Test Method (ASTM) of ASTM C1267-11, which is a modified reference method by reducing of reagent consumption by 10% of the amount used by the original method. The ASTM C 1267-11 reference is a new ASTM as a substitute for the older ASTM namely ASTM C799, Vol.12.01, 2003. It is, therefore, necessary to validate the renewed method. The tool used for the analysis of uranium was potentiometer T-90 and the material used was standard uranium oxide powder CRM (Certificate Reference Material). Validation of the method was done by analyzing standard uranium powder by 7 times weighing and 7 times analysis. Analysis results were used to determine the level of accuracy, precision, Relative Standard Deviation (RSD) and Horwitz coefficient Variation and limit detection and quantitation. The average uranium obtained for this method validation is 84.36% with Standard Deviation (SD) of 0.12%, Relative Standard Deviation (RSD) 0.14% and 2/3 Horwitz coefficient Variation (CV Horwitz) 2.05%. The results show that RSD value is smaller than the value of (2/3) CV Horwitz, which means that this method has a high precision. The accuracy value obtained is 0.48%, and since the acceptance limit of high level of accuracy is when the accuracy value is <2.00%, this method is regarded as having a high degree of accuracy [1]. The limit of detection (LOD) and and the limit of quantitation (LOQ) are 0.0145 g/L and 0.0446 g/L respectively. It is concluded that the ASTM C 1267-11 reference method is valid for use. (author)

  14. National Environmental Field Activities Program

    Science.gov (United States)

    2011-03-31

    holder community. –It is one of a kind! –Written for any type of field sampling  and testing  • Builds of the foundation of  ISO / IEC   17025 ! Why TNI...Why chose the TNI standard and not others – ISO  9000 – ISO / IEC  17020 – ISO  14000 – ASTM, USGS, EPA, Etc. – XXXXXX, XXX or XXXX REDUCE DATA VARIABILITY

  15. Investigating the effect of coil model losses on computational electromagnetic exposure of an ASTM phantom at 64 MHz MRI.

    Science.gov (United States)

    Kozlov, Mikhail; Horner, Marc; Kainz, Wolfgang; Angelone, Leonardo M

    2017-07-01

    The goal of this work is to investigate the effect of coil losses on the electromagnetic field generated in an ASTM phantom by a birdcage coil. The study was based on different numerical implementations of an RF body coil at 64 MHz, using the same 3D EM and RF circuit co-simulation procedure. The coil quality factor was evaluated with respect to losses due to power feed mismatch and to resistive losses of the coil components. The results of the study showed that the magnetic field at the coil iso-center, normalized to the square root of the whole body specific absorption rate, depends on the coil quality factor.

  16. Fuel and Fuel System Materials Compatibility Test Program for A JP-8+100 Fuel Additive. Volume 1: Thermal Stability Additive Package BetzDearborn Spec Aid(Registered) 8Q462

    Science.gov (United States)

    2001-10-01

    SAE Rings, Sealing, Butadiene-Acrylonitrile ( NBR ), Rubber Fuel and Low Temperature Resistant 60 - 70 MIL-R-83248C Rubber , Fluorocarbon...KAPTON/TEFLON (COMPOSITE) WIRE I.I.10 34 VI. REFERENCE DOCUMENTS Non-Metallics MIL-HDBK-149B Military Standardization Hand Book Rubber ...ASTM D-1414 Standard Test Methods for Rubber O-Rings ASTM D-412 Type II Standard Test Methods for Vulcanized Rubber and Thermoplastic

  17. DOE standard: Integration of environment, safety, and health into facility disposition activities. Volume 1 of 2: Technical standard

    International Nuclear Information System (INIS)

    1998-05-01

    This Department of Energy (DOE) technical standard (referred to as the Standard) provides guidance for integrating and enhancing worker, public, and environmental protection during facility disposition activities. It provides environment, safety, and health (ES and H) guidance to supplement the project management requirements and associated guidelines contained within DOE O 430.1A, Life-Cycle Asset Management (LCAM), and amplified within the corresponding implementation guides. In addition, the Standard is designed to support an Integrated Safety Management System (ISMS), consistent with the guiding principles and core functions contained in DOE P 450.4, Safety Management System Policy, and discussed in DOE G 450.4-1, Integrated Safety Management System Guide. The ISMS guiding principles represent the fundamental policies that guide the safe accomplishment of work and include: (1) line management responsibility for safety; (2) clear roles and responsibilities; (3) competence commensurate with responsibilities; (4) balanced priorities; (5) identification of safety standards and requirements; (6) hazard controls tailored to work being performed; and (7) operations authorization. This Standard specifically addresses the implementation of the above ISMS principles four through seven, as applied to facility disposition activities

  18. Next-generation services for e-traceability to ionizing radiation national standards

    International Nuclear Information System (INIS)

    Desrosiers, M.F.; Klemick, Mark; Puhl, J.M.; Uchida, David; Mallis, Steven

    2004-01-01

    An Internet-based system for fast, remote certification of high-dose radiation sources against the US national standard is being constructed at the National Institute of Standards and Technology (NIST). The new service will establish traceability (through transfer dosimetry) in real time at a lower cost by using automated routines and the Internet. A prototype of this service was successfully demonstrated in 2000 at the American Society for Testing and Materials (ASTM) Dosimetry Workshop in San Diego. Despite this impressive accomplishment, new developments demanded that several aspects of the service be modified. The new service has been completely redesigned to address these new demands and ensure greater accessibility. A description of the hardware and software configurations of this service as well as the communication and information management aspects will be presented. The Internet-based transfer certification program will provide industry with 24-h, 7-day-per-week, on-demand certifications, immediate turnaround times, and lower cost, ultimately improving the quality of the manufacturing process

  19. Next-generation services for e-traceability to ionizing radiation national standards

    Science.gov (United States)

    Desrosiers, Marc F.; Klemick, Mark; Puhl, James M.; Uchida, David; Mallis, Steven

    2004-09-01

    An Internet-based system for fast, remote certification of high-dose radiation sources against the US national standard is being constructed at the National Institute of Standards and Technology (NIST). The new service will establish traceability (through transfer dosimetry) in real time at a lower cost by using automated routines and the Internet. A prototype of this service was successfully demonstrated in 2000 at the American Society for Testing and Materials (ASTM) Dosimetry Workshop in San Diego. Despite this impressive accomplishment, new developments demanded that several aspects of the service be modified. The new service has been completely redesigned to address these new demands and ensure greater accessibility. A description of the hardware and software configurations of this service as well as the communication and information management aspects will be presented. The Internet-based transfer certification program will provide industry with 24-h, 7-day-per-week, on-demand certifications, immediate turnaround times, and lower cost, ultimately improving the quality of the manufacturing process.

  20. 46 CFR 193.01-3 - Incorporation by reference.

    Science.gov (United States)

    2010-10-01

    ... http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. Also, it is... Conshohocken, PA 19428-2959, telephone 610-832-9585, http://www.astm.org. (1) ASTM F 1121-87 (1993), Standard... Park, Quincy, MA 02269-9101, telephone 800-344-3555, http://www.nfpa.org. (1) NFPA 13-1996, Standard...

  1. 46 CFR 95.01-2 - Incorporation by reference.

    Science.gov (United States)

    2010-10-01

    ... http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. Also, it is..., PA 19428-2959, telephone 610-832-9585, http://www.astm.org. (1) ASTM F 1121-87 (1993), Standard... Park, Quincy, MA 02269-9101, telephone 800-344-3555, http://www.nfpa.org. (1) NFPA 13-1996, Standard...

  2. 46 CFR 34.01-15 - Incorporation by reference.

    Science.gov (United States)

    2010-10-01

    ... availability of this material at NARA, call 202-741-6030 or go to http://www.archives.gov/federal_register/code..., http://www.astm.org. (1) ASTM F 1121-87 (Reapproved 1993), Standard Specification for International...-9101, telephone 800-344-3555, http://www.nfpa.org. (1) NFPA 13-1996, Standard for the Installation of...

  3. 77 FR 75198 - Standard Format and Content for Post-Shutdown Decommissioning Activities Report

    Science.gov (United States)

    2012-12-19

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0299] Standard Format and Content for Post-Shutdown... regulatory guide (DG), DG-1272, ``Standard Format and Content for Post-shutdown Decommissioning Activities... Content for Post-shutdown Decommissioning Activities Report,'' which was issued in July 2000. DG-1271...

  4. Standard test method for tension testing of structural alloys in liquid helium

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method describes procedures for the tension testing of structural alloys in liquid helium. The format is similar to that of other ASTM tension test standards, but the contents include modifications for cryogenic testing which requires special apparatus, smaller specimens, and concern for serrated yielding, adiabatic heating, and strain-rate effects. 1.2 To conduct a tension test by this standard, the specimen in a cryostat is fully submerged in normal liquid helium (He I) and tested using crosshead displacement control at a nominal strain rate of 10−3 s−1 or less. Tests using force control or high strain rates are not considered. 1.3 This standard specifies methods for the measurement of yield strength, tensile strength, elongation, and reduction of area. The determination of the elastic modulus is treated in Test Method E 111. Note 1—The boiling point of normal liquid helium (He I) at sea level is 4.2 K (−269°C or −452.1°F or 7.6°R). It decreases with geographic elevation and is...

  5. DEVELOPING STANDARDS FOR ASSESSING ENVIRONMENTAL CHEMICAL, PHYSICAL, AND BIOLOGICAL STRESSORS THROUGH ASTM COMMITTEE E47: A PAST FOUNDATION OF PROVEN STANDARDS, A FUTURE OF GREAT POTENTIAL AND OPPORTUNITY

    Science.gov (United States)

    Development of standards associated with assessing the bioavailability of contaminants in sediment will be used as a case study for how standards have been developed through Committee E47. In 1987, Committee E47 established Subcommittee E47.03 on Sediment Assessment and Toxicity....

  6. Effects of thermal treatments on protein adsorption of Co-Cr-Mo ASTM-F75 alloys.

    Science.gov (United States)

    Duncan, L A; Labeed, F H; Abel, M-L; Kamali, A; Watts, J F

    2011-06-01

    Post-manufacturing thermal treatments are commonly employed in the production of hip replacements to reduce shrinkage voids which can occur in cast components. Several studies have investigated the consequences of these treatments upon the alloy microstructure and tribological properties but none have determined if there are any biological ramifications. In this study the adsorption of proteins from foetal bovine serum (FBS) on three Co-Cr-Mo ASTM-F75 alloy samples with different metallurgical histories, has been studied as a function of protein concentration. Adsorption isotherms have been plotted using the surface concentration of nitrogen as a diagnostic of protein uptake as measured by X-ray photoelectron spectroscopy. The data was a good fit to the Langmuir adsorption isotherm up to the concentration at which critical protein saturation occurred. Differences in protein adsorption on each alloy have been observed. This suggests that development of the tissue/implant interface, although similar, may differ between as-cast (AC) and heat treated samples.

  7. Tekken tests in a steel 'ASTM A 514 GR B' to determine the preheating temperature

    International Nuclear Information System (INIS)

    Quesada, Hector Juan; Zalazar, Monica; Asta, Eduardo Pablo

    2004-01-01

    Cold fissure tests are used to determine the proper preheating temperature in order to prevent fissures during the steel welding process. Tekken tests were carried out on a quenched and tempered high resistance 25.4 mm thick steel (ASTM A514 Gr.B) used in structural applications. The welding was carried out using a FCAW semiautomatic process with gas protection and low hydrogen tubular electrode E110T5-K4. Similar parameters and splicing design were later applied in production. The microstructures of the base material and the welding were determined by optic and electron microscopy. The thermal cycles of the welding were recorded in order to relate the preheating temperature with the cooling time from 800 o C - 500 o C (t 8/5 ) and from 800 o C - 100 o C (tg/1) and the presence or not of fissures. Preheating at 150 o C and t 8/5 greater than 17 s was found to guarantee fissure free welding (CW)

  8. Applying Standard Industrial Components for Active Magnetic Bearings

    Directory of Open Access Journals (Sweden)

    Bert-Uwe Koehler

    2017-02-01

    Full Text Available With the increasing number of active magnetic bearing applications, satisfying additional requirements is becoming increasingly more important. As for every technology, moving away from being a niche product and achieving a higher level of maturity, these requirements relate to robustness, reliability, availability, safety, security, traceability, certification, handling, flexibility, reporting, costs, and delivery times. Employing standard industrial components, such as those from flexible modular motion control drive systems, is an approach that allows these requirements to be satisfied while achieving rapid technological innovation. In this article, we discuss technical and non-technical aspects of using standard industrial components in magnetic bearing applications.

  9. Tekken testing to determine the preheating temperature on ASTM A514 GR B steel

    International Nuclear Information System (INIS)

    Asta, Eduardo; Zalazar, Monica; Quesada, Hector

    2003-01-01

    The cold cracking test methods are used to determine the preheating temperature in order to avoid cracking in steel welding.In this work Tekken tests on high strength quenching and tempering (ASTM A514 GrB) structural steel with a thickness of 25 mm have been made.The welds were done using a FCAW process with gas shielding and basic low hydrogen cored wire E 110T5-K4.The welding parameters and joint design applied in this work are similar to the ones used on site production.The base metal, HAZ and weld metal microstructure have been evaluated by optical and SEM microscopy.Thermal cycles records of each welding have been made to relate preheat temperature with the cooling time on the range of 800-500 degC (t8/5) or 800-100degC (t8/1) and the evidence of crack or no crack condition.Finally, a preheat temperature of 150degC and the cooling time larger than 17 s improve a welding integrity without cracks

  10. Automated acid and base number determination of mineral-based lubricants by fourier transform infrared spectroscopy: commercial laboratory evaluation.

    Science.gov (United States)

    Winterfield, Craig; van de Voort, F R

    2014-12-01

    The Fluid Life Corporation assessed and implemented Fourier transform infrared spectroscopy (FTIR)-based methods using American Society for Testing and Materials (ASTM)-like stoichiometric reactions for determination of acid and base number for in-service mineral-based oils. The basic protocols, quality control procedures, calibration, validation, and performance of these new quantitative methods are assessed. ASTM correspondence is attained using a mixed-mode calibration, using primary reference standards to anchor the calibration, supplemented by representative sample lubricants analyzed by ASTM procedures. A partial least squares calibration is devised by combining primary acid/base reference standards and representative samples, focusing on the main spectral stoichiometric response with chemometrics assisting in accounting for matrix variability. FTIR(AN/BN) methodology is precise, accurate, and free of most interference that affects ASTM D664 and D4739 results. Extensive side-by-side operational runs produced normally distributed differences with mean differences close to zero and standard deviations of 0.18 and 0.26 mg KOH/g, respectively. Statistically, the FTIR methods are a direct match to the ASTM methods, with superior performance in terms of analytical throughput, preparation time, and solvent use. FTIR(AN/BN) analysis is a viable, significant advance for in-service lubricant analysis, providing an economic means of trending samples instead of tedious and expensive conventional ASTM(AN/BN) procedures. © 2014 Society for Laboratory Automation and Screening.

  11. Standard specification for deuterium oxide

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Minimum requirements are set forth for D 2 O to be used as a moderator in heavy water moderated reactors. Requirements are specified for isotopic content, electrical conductivity, consumption of KMnO 4 , turbidity, total solids, and chlorides. ASTM test methods are cited for the determination of each of these requirements

  12. 40 CFR 264.1101 - Design and operating standards.

    Science.gov (United States)

    2010-07-01

    ... the American Concrete Institute (ACI) and the American Society of Testing Materials (ASTM) in judging... they are exposed; climatic conditions; and the stresses of daily operation, including the movement of...

  13. 76 FR 13631 - Food and Drug Administration Modernization Act of 1997: Modifications to the List of Recognized...

    Science.gov (United States)

    2011-03-14

    ... (Reapproved 2008). Ultra-High Molecular Weight Polyethylene Used in Surgical Implants. F. Nanotechnology 18-1... equipment. I. Tissue Engineering 15-25 ASTM F2312--10 Standard ASTM F2312-10. Terminology Relating to Tissue...

  14. 炭素繊維複合材料に対する無孔圧縮試験方法の相互比較と簡便な試験法(NAL-II法)の提案

    OpenAIRE

    Ogasawara, Toshio; Ishikawa, Takashi; 小笠原, 俊夫; 石川, 隆司

    2009-01-01

    A specific non-hole compressive (NHC) test method for advanced composite materials has not been widely authorized even now because of the essential difficulty of NHC tests. In this study, standard test methods such as SRM-1 (SACMA), Celanese (former ASTM D3410 A-method), ASTM D695, ASTM D6484 (SRM-3), ASTM D6641 (CLC), JIS K7076 (A method) were evaluated for three kinds of quasi-isotropic carbon/epoxy composites (CFRP). Furthermore, two kinds of original compressive test methods, i.e.NAL-I, I...

  15. 40 CFR 265.1101 - Design and operating standards.

    Science.gov (United States)

    2010-07-01

    ... industry such as the American Concrete Institute (ACI) and the American Society of Testing Materials (ASTM... wastes to which they are exposed; climatic conditions; and the stresses of daily operation, including the...

  16. Computer program for obtaining thermodynamic and transport properties of air and products of combustion of ASTM-A-1 fuel and air

    Science.gov (United States)

    Hippensteele, S. A.; Colladay, R. S.

    1978-01-01

    A computer program for determining desired thermodynamic and transport property values by means of a three-dimensional (pressure, fuel-air ratio, and either enthalpy or temperature) interpolation routine was developed. The program calculates temperature (or enthalpy), molecular weight, viscosity, specific heat at constant pressure, thermal conductivity, isentropic exponent (equal to the specific heat ratio at conditions where gases do not react), Prandtl number, and entropy for air and a combustion gas mixture of ASTM-A-1 fuel and air over fuel-air ratios from zero to stoichiometric, pressures from 1 to 40 atm, and temperatures from 250 to 2800 K.

  17. A new U.S. film system classification and image quality assessment

    International Nuclear Information System (INIS)

    Knell, M.

    1996-01-01

    The last ASTM Standard E94 which classified Industrial Radiography films was published in 1984. Since that time inspection contracts in US and worldwide have continued to specify Type 1 and Type 2 films--although these no longer exist. From 1990 there was discussion within ASTM and work was done by ASTM Committee E07-01. The method proposed used data on graininess and gradient to produce an index to represent quality. In the early version the author found that it was possible to have a very fine grain low-contrast film with the same index as a fine grain film, with high contrast. The draft standard was then developed, so that it is possible to classify both types of film in separate groups. The first is the Classical type of film and the second is a Wide Latitude film. In a Classical film, the contrast increases over the useable density range. The range of application standards specify densities generally from D = 2.0 to D = 4.0. A radiologist would expect contrast to be higher at D = 4.0 compared with contrast at D = 2.0. The new ASTM film classification uses a signal to noise ratio--with minimum values for each class for contrast and a maximum value for graininess. The ASTM Classification System uses the same parameters as the European Standard EN584-1 and ISO CD

  18. Directory of DOE and contractor personnel involved in non-government standards activities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    This document contains a listing of DOE employees and DOE contractors who have submitted form DOE F 1300.2, Record of Non-Government Standards Activity. Additional names were added from rosters supplied by non-Government standards bodies.

  19. Standardized reactors for the study of medical biofilms: a review of the principles and latest modifications.

    Science.gov (United States)

    Gomes, Inês B; Meireles, Ana; Gonçalves, Ana L; Goeres, Darla M; Sjollema, Jelmer; Simões, Lúcia C; Simões, Manuel

    2018-08-01

    Biofilms can cause severe problems to human health due to the high tolerance to antimicrobials; consequently, biofilm science and technology constitutes an important research field. Growing a relevant biofilm in the laboratory provides insights into the basic understanding of the biofilm life cycle including responses to antibiotic therapies. Therefore, the selection of an appropriate biofilm reactor is a critical decision, necessary to obtain reproducible and reliable in vitro results. A reactor should be chosen based upon the study goals and a balance between the pros and cons associated with its use and operational conditions that are as similar as possible to the clinical setting. However, standardization in biofilm studies is rare. This review will focus on the four reactors (Calgary biofilm device, Center for Disease Control biofilm reactor, drip flow biofilm reactor, and rotating disk reactor) approved by a standard setting organization (ASTM International) for biofilm experiments and how researchers have modified these standardized reactors and associated protocols to improve the study and understanding of medical biofilms.

  20. 46 CFR 56.01-2 - Incorporation by reference.

    Science.gov (United States)

    2010-10-01

    ... Welded Ferritic and Martensitic Stainless Steel Tubing for General Service (“ASTM A 268”), 56.60-1; (21) ASTM A 276-98, Standard Specification for Stainless Steel Bars and Shapes (“ASTM A 276”), 56.60-2; (22... (27) ASME B36.19M-2004 Stainless Steel Pipe (2004) (“ASME B36.19M”), 56.07-5; 56.60-1. (28) ASME SA...

  1. Laboratory Evaluation of Light Obscuration Particle Counter Contamination Limits for Aviation Fuel

    Science.gov (United States)

    2015-11-01

    assurance testing though conducting periodic fuel sampling for gravimetric analysis. The Army currently utilizes two methods for measuring particulate...contamination by gravimetric analysis: ASTM D2276 - Standard Test Method for Particulate Contaminant in Aviation Fuel by Line Sampling, and ASTM D5452...while filter effectiveness is checked every 30 days by gravimetric analysis (ASTM D2276). One of the problems with the gravimetric methods is the

  2. Laboratory Evaluation of Light Obscuration Particle Counters used to Establish use Limits for Aviation Fuel

    Science.gov (United States)

    2015-12-01

    The Army currently utilizes two methods for measuring particulate contamination by gravimetric analysis: ASTM D2276 - Standard Test Method for...is checked every 30 days by gravimetric analysis (ASTM D2276). One of the problems with the gravimetric methods is the poor repeatability and...ASTM D2276 testing is an artifact of that method . The correlation of particle counter data to the theoretical gravimetric concentration, and cross

  3. Protocol for Cohesionless Sample Preparation for Physical Experimentation

    Science.gov (United States)

    2016-05-01

    Standard test method for consolidated drained triaxial compression test for soils . In Annual book of ASTM standards. West Conshohocken, PA: ASTM...derived wherein uncertainties and laboratory scatter associated with soil fabric-behavior variance during sample preparation are mitigated. Samples of...wherein comparable analysis between different laboratory tests’ results can be made by ensuring a comparable soil fabric prior to laboratory testing

  4. Kinetic and morphological differentiation of ettringites in plain and blended Portland cements with metakaolin and the ASTM C 452-68 test. Part II: Morphological differentiation by SEM and XRD analysis

    Directory of Open Access Journals (Sweden)

    Talero, R.

    2009-03-01

    Full Text Available The same cementitious materials (OPCs, SRPCs and matekaolin, MK, the same blended cements and the same ASTM C 452-68 test than in Part I, were used. Other complementary determinations were: chemical analysis of cementing materials, SEM and XRD analysis of ettringites and specific properties of some cement tested and of their pastes.The experimental results have also demonstrated that when 7.0% SO3, equivalent to 15.05% of gypsum, was added to the M pozzolan-containing Portland cement and tested with the ASTM C 452-68 method, it was not found to behave aggressively but rather as “setting regulator ”, because the increase in mechanical strengths over time and setting times in these mixes were, therefore, similar to the pattern observed in any PC. However, when the gypsum content was raised to triple than that amount (21.0% SO3, it behaved aggressively. In both cases, logically, ettringite from both origins were involved in the resulting beneficial or adverse behavior.En esta Parte II se utilizaron los mismos materiales cementíceos (CPO, CPRS, y metakaolín, MK, los mismos cementos de mezcla y el mismo método de ensayo ASTM C 452-68 que en la Parte I. Otras determinaciones complementarias fueron: análisis químico de los materiales cementíceos, análisis por DRX y SEM de ettringitas y propiedades específicas de algunos cementos ensayados y de sus pastas.Los resultados experimentales obtenidos han demostrado también que, el 7.0% de SO3 presente en los 30 cementos de mezcla con MK, ensayados conforme el método ASTM C 452-68, no se comporta como agresivo sino como ”regulador de fraguado”, porque los tiempos de fraguado y el aumento de resistencias mecánicas fueron como los de cualquier CP. De aquí que algunos de esos cementos de mezcla puedan ser considerados “cementos hidráulicos expansivos”, el resto, no. Sin embargo, cuando la cantidad de yeso aportada fue el triple (21,0% SO3, se comportó como agresivo, motivo por el cual

  5. Standard test method for isotopic abundance analysis of uranium hexafluoride and uranyl nitrate solutions by multi-collector, inductively coupled plasma-mass spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2014-01-01

    1.1 This test method covers the isotopic abundance analysis of 234U, 235U, 236U and 238U in samples of hydrolysed uranium hexafluoride (UF6) by inductively coupled plasma source, multicollector, mass spectrometry (ICP-MC-MS). The method applies to material with 235U abundance in the range of 0.2 to 6 % mass. This test method is also described in ASTM STP 1344. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  6. Kinetic and morphological differentiation of Ettringites in plain and blended Portland cements using Metakaolin and the ASTM C 452-68 test. Part I: kinetic differentiation

    Directory of Open Access Journals (Sweden)

    Talero, R.

    2008-12-01

    Full Text Available In this first part of the study, the results obtained in prior research with XRD and SEM, as well as the Le Chatelier-Ansttet test were confirmed with the ASTM C 452-68 test. To this end, 20%, 30% and 40% metakaolin (MK was added to ten Portland cements, six OPCs and four SRPCs. Both the ten plain PCs and the 30 metakaolin (MK blends were tested for two years under ASTM C 452-68 specifications, determining not only the percentage increase in length, ΔL(%, of the specimens, but also the sulphate content in the curing water. Other parameters studied included: chemical analysis of the cementitious materials used and specific properties of some of the cements tested.The experimental results, ΔL(% versus time, re-confirmed that the formation rate of ettringite from the reactive alumina, Al2O3r-, present in the pozzolan must be substantially higher than the formation rate of ettringite from the C3A present in the PC. This was verified by the variation of the sulphate content in the specimen curing water throughout the test. In light of those findings, in this article these two types of ettringite are denominated rapid forming ettringite or ett-rf, and slow forming ettringite or ett-lf.En esta Parte I de la investigación, se han logrado verificar mediante el ensayo ASTM C 452-68, los resultados obtenidos en anteriores investigaciones realizadas con DRX y SEM y el ensayo Le Chatelier-Ansttet. Para ello, a 10 cementos Portland –6 CPO y 4 CPRS– se les añadió 20%, 30% y 40% de metakaolín (MK. Tanto los 10 CP como los 30 de sus mezclas con metakaolín (MK, se ensayaron durante 2 años, mediante dicho método ASTM C 452-68, y a sus probetas no sólo se les determinó su incremento porcentual de longitud, ΔL(%, sino además, el contenido de sulfatos de sus aguas de conservación. Otras determinaciones complementarias fueron: análisis químico de los materiales cementiceos utilizados y propiedades específicas de algunos cementos ensayados

  7. Effects of heat treatment to the sound velocity and microstructural changes of ASTM A516 steels

    International Nuclear Information System (INIS)

    Norasiah Abdul Kasim; Azali Muhammad; Amry Amin Abas; Zaiton Selamat

    2010-01-01

    Full-text: The used of ultrasonic testing as a thickness measurement for structural components (pipeline and pressure vessel) is among the popular inspection tool widely use in the industrial power plant such as at petrochemical and nuclear power plant. Currently, there are cases where the thickness grows and the result will affect the reliability of the test. There are many factors that can affect the reliability of measurement. One of it is the material under test itself. In the Malaysian Nuclear Agency, initial efforts are underway to study the understanding on the effects of heat treatment to the sound velocity and microstructure changes of ASTM A516 steel. Few samples of thin square shaped prepared were heat treated under the following conditions: austenitization at 9800 degree Celsius - 2 hours, quenching; tempering at various temperature 4000, 5000, 6000 and 7000 degree Celsius. The results show that the microstructure changes and samples exhibit different sound velocity at different heat treatment. (author)

  8. Defense Standardization Program Journal, July/December 2007

    Science.gov (United States)

    2007-12-01

    IeqLuirelleCnlts. About the Authors Robert Stenner , a toxicologist at Pacific Northwest National Laboratory (PNNL), has more than 30 years ot experience...in emergency response, environmental health risk analysis, and human health impact analysis of xenobiotic agents. Dr. Stenner also chairs ASTM

  9. The preparation of synthetic standards for use in instrumental neutron-activation analysis

    International Nuclear Information System (INIS)

    Eddy, B.T.; Watterson, J.I.W.; Erasmus, C.S.

    1979-01-01

    An account is given of the formulation and preparation of synthetic standards suitable for the routine analysis of minerals, ores, and ore concentrates by instrumental neutron activation. Fifteen standards were prepared, each containing from one to seven elements. The standards contain forty-four elements that produce isotopes with half-lives longer than 12 hours. An evaluation of the accuracy and precision of the method of preparation is given

  10. 78 FR 45051 - Small Business Size Standards; Support Activities for Mining; Correction

    Science.gov (United States)

    2013-07-26

    ... Regulations by increasing small business size standards for three of the four industries in North American... SMALL BUSINESS ADMINISTRATION 13 CFR Part 121 RIN 3245-AG44 Small Business Size Standards; Support Activities for Mining; Correction AGENCY: U.S. Small Business Administration. ACTION: Final rule; correction...

  11. Mechanical and thermal properties of prepacked aggregate ...

    Indian Academy of Sciences (India)

    Hossein Mohammadhosseini

    water to acquire stable, low-energy state, and the process is accompanied by the ... great quantity of activated silica. It is a byproduct of ... temperature of the water and inner side of the concrete specimens. ..... [24] ASTM C618 2015 Standard specification for coal fly ash and ... treated ground palm oil fuel ash. Constr. Build.

  12. Material specification for ductile cast iron in the United States

    International Nuclear Information System (INIS)

    Sorenson, K.B.

    1987-01-01

    The United States currently does not have formal design criteria for qualifying ductile cast iron (DCI) transportation casks. There is also no dedicated material standard for DCI for this particular application. A draft ASTM material specification has been written and is currently in the ASTM approval process. This paper reviews the brief history of the development of the specification, the technical basis for the material properties, the ASTM approval process and the current status of the draft specification. The expected implications of having an adopted ASTM specification on the licensing process are also discussed. (orig./DG)

  13. Reassessing the standard chest radiograph for intraparenchymal activity

    International Nuclear Information System (INIS)

    Putman, C.E.; Hoeck, B.

    1986-01-01

    Despite the recent enthusiasm for better means of determining the extent of the active inflammatory response in the lung parenchyma of sarcoidosis patients, standard chest radiography remains a reliable method of determining staging, and parenchymal activity as well. The chest radiograph is characteristically used to determine the severity and course of sarcoidosis, but most studies imply there are poor correlations between the radiographic opacities and other indicators such as physiological parameters, gallium scans, and computed tomography and bronchoalveolar lavage results. In this preliminary communication, the authors report a new method of determining sarcoidosis activity, as compared to gallium scan, based solely on the standard chest radiograph. This method is based on the presence or absence of air bronchogram abnormalities, peribronchial cuffing, and subpleural thickening. Adenopathy and linear, reticulonodular, and nodular opacities are not included in this system. In 85 recent studies, which were performed in 51 patients with biopsy-proven sarcoidosis, this staging method agreed with gallium scanning in 68.2% of the patients. This system failed in specific and identifiable subgroups of patients that we will delineate. The authors will not report the comparative indices with a pulmonary function analysis or bronchoalveolar lavage results. Their database has not been tabulated to conclusively present these results, but it is their belief that this methodology will probably have a better correlation with lavage results and small airway function than would results of gallium scans. Of singular importance is the fact that this method can, with a more than acceptable degree of accuracy, distinguish between ''low-intensity'' alveolitis and ''high-intensity'' alveolitis

  14. 77 FR 29757 - Guidelines Establishing Test Procedures for the Analysis of Pollutants Under the Clean Water Act...

    Science.gov (United States)

    2012-05-18

    ...: Inductively Coupled Plasma-Atomic Emission Spectroscopy ICP/MS: Inductively Coupled Plasma-Mass Spectrometry...): ``Determination of Trace Elements in Drinking Water by Axially Viewed Inductively Coupled Plasma--Atomic Emission... Committee, and ASTM International. Standard Methods and ASTM are available in printed or electronic...

  15. Development of standard ionization chamber counting system for activity measurements

    International Nuclear Information System (INIS)

    Pyun, Woong Beom; Lee, Hyun Koo; Lee, Hai Yong; Park, Tae Soon

    1998-01-01

    This study is to set up the activity measuring system using a 4π γ ionization chamber as used mainly in national standards laboratories that are responsible for radionuclide metrology. The software for automatic control between the electrometer and personal computer is developed using Microsoft visual basic 4.0 and IEEE488 Interface. The reproducibility of this 4π γ ionization chamber is about 0.02% and the background current is 0.054±0.024 pA. this 4π γ ionization chamber is calibrated by 6 standard gamma emitting radionuclides from KRISS. According to the result of this study, it is revealed that this 4π γ ionization chamber counting system can be used as a secondary standard instrument for radioactivity measurement

  16. Development of standard ionization chamber counting system for activity measurements

    CERN Document Server

    Pyun, W B; Lee, H Y; Park, T S

    1998-01-01

    This study is to set up the activity measuring system using a 4 pi gamma ionization chamber as used mainly in national standards laboratories that are responsible for radionuclide metrology. The software for automatic control between the electrometer and personal computer is developed using Microsoft visual basic 4.0 and IEEE488 Interface. The reproducibility of this 4 pi gamma ionization chamber is about 0.02% and the background current is 0.054+-0.024 pA. this 4 pi gamma ionization chamber is calibrated by 6 standard gamma emitting radionuclides from KRISS. According to the result of this study, it is revealed that this 4 pi gamma ionization chamber counting system can be used as a secondary standard instrument for radioactivity measurement.

  17. Development of healthy eating and physical activity quality standards for out-of-school time programs.

    Science.gov (United States)

    Wiecha, Jean L; Hall, Georgia; Gannett, Ellen; Roth, Barbara

    2012-12-01

    Out-of-school time (OST) programs serve over 8 million children per year and have ample opportunity to promote health through menu and physical activity choices. Until recently, however, the field has lacked a comprehensive set of operationalizable standards for healthy eating and physical activity. The National AfterSchool Association adopted voluntary healthy eating and physical activity quality standards (HEPAQS) in April, 2011. We describe the development of HEPAQS. This work reflects a social ecological model for changing children's eating and activity behaviors through program-level interventions. The standards were developed using a national, mixed-methods needs assessment, review of existing standards and expert recommendations, and a participatory process of discussion, review, and consensus engaging 19 influential service and policy organizations and agencies in the Healthy Out-of-School Time (HOST) coalition, which we convened in 2009. The HOST coalition approved a final version of the HEPAQS in January, 2011. The 11 standards address content, curriculum selection, staff training, program support, and environmental support for healthy eating and physical activity. In April, 2011, the HEPAQS were adopted by the National AfterSchool Association, and have subsequently been widely disseminated. Extensive adoption and implementation efforts are underway. The availability of a comprehensive set of standards for healthy eating and physical activity in OST provides practical information to help community-based youth-serving organizations participate in obesity and chronic disease prevention. A working awareness of their content will be useful to scientists undertaking health promotion studies in the out-of-school time setting.

  18. Synthetic multielement standards used for instrumental neutron activation analysis as rock imitations

    International Nuclear Information System (INIS)

    Leypunskaya, D.I.; Drynkin, V.I.; Belenky, B.V.; Kolomijtsev, M.A.; Dundera, V.Yu.; Pachulia, N.V.

    1975-01-01

    Complex (multielemental) standards representing microelement composition of standard rocks such as trap ST-1 (USSR), gabbrodiorite SGD-1 (USSR), albitized granite SG-1 (USSR), basalt BCR-1 (USA) and granodiorite GSP-1 (USA) have been synthesized. It has been shown that the concentration of each microelement in the synthetic standards can be given with a high precision. Comparative investigation has been carried out of the synthetic imitations and the above natural standard rocks. It has been found that the result of the instrumental neutron activation analysis using the synthetic standards is as good as in the case when natural standard rocks are used. The results obtained have been also used for substantiation of the versatility of the method used for standard preparation, i.e. a generalization has been made of a possibility of using this method for the preparation of synthetic standards representing the microelement composition of any natural rocks with various compositions and concentrations of microelements. (T.G.)

  19. OPTIMIZACION DE LAS PROPIEDADES DE TRANSPORTE IONICO DEL CONCRETO Y SIMULACION DEL ENSAYO ASTM C1202

    Directory of Open Access Journals (Sweden)

    JUAN LIZARAZO MARRIAGA

    2009-01-01

    Full Text Available En este artículo se presentan los resultados de la simulación computacional del flujo de los principales iones presentes (Cl-, OH-, Na+, y K+ en un ensayo ASTM C1202: "Indicación eléctrica de la resistencia del concreto a la penetración de Iones cloruro". Para la modelación se utilizó un esquema de diferencias finitas definido mediante la ecuación de Nernst - Plank con un campo eléctrico variable, la cual describe los movimientos iónicos en un material poroso saturado. Para lograr esto, los resultados de un nuevo ensayo electroquímico diseñado para medir el potencial de membrana, en compañía de la corriente eléctrica, fueron optimizados para obtener los coeficientes intrínsicos de difusión, la composición inicial de la solución de poros, la capacidad de fijación de cloruros y la porosidad de la mezcla de concreto.

  20. Argentine nuclear energy standardization activities

    International Nuclear Information System (INIS)

    Boero, Norma; Corcuera, Roberto; Palacios, Tulio A.; Hey, Alfredo M.; Berte, G.; Trama, L.

    2004-01-01

    The International Organization for Standardization (ISO) has more than 200 Technical Committees that develop technical standards. During April 2004 took place in Buenos Aires the 14th Plenary of the ISO/TC 85 Nuclear Energy Committee. During this Plenary issues as Nuclear Terminology, Radiation Protection, Nuclear Fuels, Nuclear Reactors and Irradiation Dosimetry was dealt with. 105 International delegates and 45 National delegates (belonging to CNEA, ARN, NASA, INVAP, CONUAR, IONICS and other organizations) attended the meetings. During this meeting ISO/TC 85 changed its scope; the new scope of the Committee is 'Standardization in the fields of peaceful applications of nuclear energy and of the protection of individuals against all sources of ionizing radiations'. This work summarizes the most important advances and resolutions about the development of standards taken during this meeting as well as the main conclusions. (author) [es

  1. Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns for New Instrument Standards

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stratton, Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-08-01

    This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The study team prepared a draft test method through ASTM International to determine the uncertainty of air flow measurements at residential heating ventilation and air conditioning returns and other terminals. This test method, when finalized, can be used by the Energy Commission and other entities to specify required accuracy of measurement devices used to show compliance with standards.

  2. Standard reference radiographs for steel castings up to 2 in. (50.8 mm) in thickness

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice describes accepted procedures for and factors that influence laboratory immersion corrosion tests, particularly mass loss tests. These factors include specimen preparation, apparatus, test conditions, methods of cleaning specimens, evaluation of results, and calculation and reporting of corrosion rates. This practice also emphasizes the importance of recording all pertinent data and provides a checklist for reporting test data. Other ASTM procedures for laboratory corrosion tests are tabulated in the Appendix. (Warning-In many cases the corrosion product on the reactive metals titanium and zirconium is a hard and tightly bonded oxide that defies removal by chemical or ordinary mechanical means. In many such cases, corrosion rates are established by mass gain rather than mass loss.) 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. This standard does not purport to address all of the safety concerns, if any, assoc...

  3. Caracterização microestrutural de soldas dissimilares dos aços ASTM A-508 e AISI 316L Characterization of dissimilar metal weld between low alloy steel ASTM A-508 and 316L stainless steel

    Directory of Open Access Journals (Sweden)

    Luciana Iglésias Lourenço Lima

    2010-06-01

    Full Text Available As soldas dissimilares (dissimilar metal welds - DMWs são utilizadas em diversos segmentos da indústria. No caso específico de usinas nucleares, tais soldas são necessárias para conectar tubulações de aço inoxidável com componentes fabricados em aços baixa liga. Os materiais de adição mais utilizados neste tipo de solda são as ligas de níquel 82 e 182. Este trabalho consistiu na soldagem de uma junta dissimilar de aço baixa liga ASTM A-508 G3 e aço inoxidável austenítico AISI 316L utilizando as ligas de níquel 82 e 182 como metais de adição. A soldagem foi realizada manualmente empregando os processos de soldagem ao arco SMAW (Shielded Metal Arc Welding e GTAW (Gas Tungsten Arc Welding. Os corpos de prova foram caracterizados microestruturalmente utilizando-se microscópio óptico e microscópio eletrônico de varredura com microanálise por dispersão de energia de raios X (EDS e ensaios de microdureza Vickers. Observou-se uma microestrutura constituída de dendritas de austenita com a presença de precipitados com formas e dimensões definidas pelo aporte térmico e pela direção de soldagem. Não houve variação significativa da dureza ao longo da junta soldada, demonstrando a adequação dos parâmetros de soldagem utilizados.The dissimilar metal welds (DMWs are used in several areas of the industries. In the nuclear power plant, this weld using nickel alloy welding wires is used to connect stainless steel pipes to low alloy steel components on the reactor pressured vessels. The filler materials commonly used in this type of weld are nickel alloys 82 and 182.. In this study, dissimilar metal welds composed of low alloy steel ASTM A-508 G3, nickel alloys 82 e 182 as weld metals, and austenitic stainless steel AISI 316L were prepared by manual shielded metal arc welding (SMAW and gas tungsten arc welding techniques (GTAW. Samples were microstructural characterized by optical microscopy and scanning electron microscopy

  4. 40 CFR 721.4215 - Hexanedioic acid, diethenyl ester.

    Science.gov (United States)

    2010-07-01

    ... SUBSTANCES CONTROL ACT SIGNIFICANT NEW USES OF CHEMICAL SUBSTANCES Significant New Uses for Specific Chemical... in accordance with the most current version of the American Society for Testing and Materials (ASTM... most current version of ASTM F1383 “Standard Test Method for Resistance of Protective Clothing...

  5. Filtration Effects Due to Bioassay Cage Design and Screen Type

    Science.gov (United States)

    2010-01-01

    Optical Nonimaging Light- Scattering Instruments (ASTM, 2003). Droplet sizing data included volume median diam (DV50), and the 10% and 90% diam (DV10 and...optical nonimaging light-scattering instru- ments. In: Annual book of ASTM standards. West Conshohocken, PA: American Society for Testing and Materials

  6. Application of Indenting Method for Calculation of Activation Energy

    International Nuclear Information System (INIS)

    Kim, Jong-Seog; Kim, Tae-Ryong

    2006-01-01

    For the calculation of activation energy of cable materials, we used to apply the break-elongation test in accordance with ASTM D412(Stand Test Methods for Rubber Properties in Tension). For the cable jacket and insulation which have regular thickness, break-elongation test had been preferred since it showed linear character in the activation energy curve. But, for the cable which has irregular thickness or rugged surface of cable inside, break-elongation test show scattered data which can not be used for the calculation of activation energy. It is not easy to prepare break-elongation specimen for the cable smaller than 13mm diameter in accordance with ASTM D412. In the cases of above, we sometime use TGA method which heat the specimen from 50 .deg. C to 700 .deg. C at heating rates of 10, 15, 20 .deg. C/min. But, TGA is suspected for the representative of natural aging in the plant since it measure the weight decreasing rate during burning which may have different aging mechanism with that of natural aging. To solve above problems, we investigated alternatives such as indenter test. Indenter test is very convenient since it does not ask for a special test specimen as the break-elongation test does. Regular surface of cable outside is the only requirement of indenter test. Experience of activation energy calculation by using the indenter test is described herein

  7. A generic standard for assessing and managing activities with significant risk to health and safety

    International Nuclear Information System (INIS)

    Wilde, T.S.; Sandquist, G.M.

    2005-01-01

    Some operations and activities in industry, business, and government can present an unacceptable risk to health and safety if not performed according to established safety practices and documented procedures. The nuclear industry has extensive experience and commitment to assessing and controlling such risks. This paper provides a generic standard based upon DOE Standard DOE-STD-3007- 93, Nov 1993, Change Notice No. 1, Sep 1998. This generic standard can be used to assess practices and procedures employed by any industrial and government entity to ensure that an acceptable level of safety and control prevail for such operations. When any activity and operation is determined to involve significant risk to health and safety to workers or the public, the organization should adopt and establish an appropriate standard and methodology to ensure that adequate health and safety prevail. This paper uses DOE experience and standards to address activities with recognized potential for impact upon health and safety. Existing and future assessments of health and safety issues can be compared and evaluated against this generic standard for insuring that proper planning, analysis, review, and approval have been made. (authors)

  8. Secondary standards (non-activation) for neutron data measurements above 20 MeV

    International Nuclear Information System (INIS)

    Haight, R.C.

    1991-01-01

    In addition to H(n,p) scattering and 235,238 U(n,f) reactions, secondary standards for neutron flux determination may be useful for neutron energies above 20 MeV. For experiments where gamma rays are detected, reference gamma-ray production cross sections are relevant. For neutron-induced charged particle production, standard (n,p) and (n,alpha) cross sections would be helpful. Total cross section standards would serve to check the accuracy of these measurements. These secondary standards are desirable because they can be used with the same detector systems employed in measuring the quantities of interest. Uncertainties due to detector efficiency, geometrical effects, timing and length of flight paths can therefore be significantly reduced. Several secondary standards that do not depend on activation techniques are proposed. 14 refs

  9. Neutron activation analysis for certification of standard reference materials

    International Nuclear Information System (INIS)

    Capote Rodriguez, G.; Perez Zayas, G.; Hernandez Rivero, A.; Ribeiro Guevara, S.

    1996-01-01

    Neutron activation analysis is used extensively as one of the analytical techniques in the certification of standard reference materials. Characteristics of neutron activation analysis which make it valuable in this role are: accuracy multielemental capability to asses homogeneity, high sensitivity for many elements, and essentially non-destructive method. This paper report the concentrations of 30 elements (major, minor and trace elements) in four Cuban samples. The samples were irradiated in a thermal neutron flux of 10 12- 10 13 n.cm 2. s -1. The gamma ray spectra were measured by HPGe detectors and were analyzed using ACTAN program development in Center of Applied Studies for Nuclear Development

  10. Effects of oxidation-nitridation in the presence of water vapor on ASTM A335 P92 steel using SEM-EDS and XPS characterization techniques

    Science.gov (United States)

    Orozco, J. C.; Kafarov, V.; Y Peña, D.; Alviz, A.

    2017-12-01

    This research studies the physical and chemical changes in steel ASTM A335 P92, produced from a typical refinery corrosion environment. The environment evaluated was oxidation-nitridation with the presence of water vapor. In this study five (5) exposure times were selected: 1, 20, 50, 100 and 200 hours; As well as two (2) analysis temperatures: 450 and 550°C. The working pressure used was one (1) atmosphere. Bearing in mind the kinetic study, the behaviour shown in ASTM A335 P92 steel describes an accelerated growth until 50 hours, after this time growth is less. For the tests carried out at 450°C, the kinetic constant was 2x10-8g2mm-4h-1, as well as for 550°C the calculated kinetic constant was 3.1×10-7g2mm-4h-1 through the SEM-EDS characterization techniques, it was possible to appreciate a good adhesion and homogeneity of the layers formed on the metal matrix until a time of exposure of 100 hours at 450 and 550°C, different from that evidenced to 200 hours of exposure where the layer formed near to the substrate showed detachment, this is attributed to the formation of hydroxides product of water vapor. Among the results obtained are the elemental composition, the presence of nitrides such as Si3N4, also NSiO2 and NSi2O, molybdenum oxides: MoO2 and MoO3 and iron oxides: FeO and Fe2O3 can be evidenced.

  11. 40 CFR 721.5310 - Neononanoic acid, ethenyl ester.

    Science.gov (United States)

    2010-07-01

    ... SUBSTANCES CONTROL ACT SIGNIFICANT NEW USES OF CHEMICAL SUBSTANCES Significant New Uses for Specific Chemical... accordance with the most current version of the American Society for Testing and Materials (ASTM) F739... current version of ASTM F1383 “Standard Test Method for Resistance of Protective Clothing Materials to...

  12. 40 CFR 721.4250 - Hexanoic acid, 2-ethyl-, ethenyl ester.

    Science.gov (United States)

    2010-07-01

    ... SUBSTANCES CONTROL ACT SIGNIFICANT NEW USES OF CHEMICAL SUBSTANCES Significant New Uses for Specific Chemical... accordance with the most current version of the American Society for Testing and Materials (ASTM) F739... current version of ASTM F1383 “Standard Test Method for Resistance of Protective Clothing Materials to...

  13. Applications of Automation Methods for Nonlinear Fracture Test Analysis

    Science.gov (United States)

    Allen, Phillip A.; Wells, Douglas N.

    2013-01-01

    Using automated and standardized computer tools to calculate the pertinent test result values has several advantages such as: 1. allowing high-fidelity solutions to complex nonlinear phenomena that would be impractical to express in written equation form, 2. eliminating errors associated with the interpretation and programing of analysis procedures from the text of test standards, 3. lessening the need for expertise in the areas of solid mechanics, fracture mechanics, numerical methods, and/or finite element modeling, to achieve sound results, 4. and providing one computer tool and/or one set of solutions for all users for a more "standardized" answer. In summary, this approach allows a non-expert with rudimentary training to get the best practical solution based on the latest understanding with minimum difficulty.Other existing ASTM standards that cover complicated phenomena use standard computer programs: 1. ASTM C1340/C1340M-10- Standard Practice for Estimation of Heat Gain or Loss Through Ceilings Under Attics Containing Radiant Barriers by Use of a Computer Program 2. ASTM F 2815 - Standard Practice for Chemical Permeation through Protective Clothing Materials: Testing Data Analysis by Use of a Computer Program 3. ASTM E2807 - Standard Specification for 3D Imaging Data Exchange, Version 1.0 The verification, validation, and round-robin processes required of a computer tool closely parallel the methods that are used to ensure the solution validity for equations included in test standard. The use of automated analysis tools allows the creation and practical implementation of advanced fracture mechanics test standards that capture the physics of a nonlinear fracture mechanics problem without adding undue burden or expense to the user. The presented approach forms a bridge between the equation-based fracture testing standards of today and the next generation of standards solving complex problems through analysis automation.

  14. XML and its impact on content and structure in electronic health care documents.

    Science.gov (United States)

    Sokolowski, R.; Dudeck, J.

    1999-01-01

    Worldwide information networks have the requirement that electronic documents must be easily accessible, portable, flexible and system-independent. With the development of XML (eXtensible Markup Language), the future of electronic documents, health care informatics and the Web itself are about to change. The intent of the recently formed ASTM E31.25 subcommittee, "XML DTDs for Health Care", is to develop standard electronic document representations of paper-based health care documents and forms. A goal of the subcommittee is to work together to enhance existing levels of interoperability among the various XML/SGML standardization efforts, products and systems in health care. The ASTM E31.25 subcommittee uses common practices and software standards to develop the implementation recommendations for XML documents in health care. The implementation recommendations are being developed to standardize the many different structures of documents. These recommendations are in the form of a set of standard DTDs, or document type definitions that match the electronic document requirements in the health care industry. This paper discusses recent efforts of the ASTM E31.25 subcommittee. PMID:10566338

  15. Methods for preparing comparative standards and field samples for neutron activation analysis of soil

    International Nuclear Information System (INIS)

    Glasgow, D.C.; Dyer, F.F.; Robinson, L.

    1995-01-01

    One of the more difficult problems associated with comparative neutron activation analysis (CNAA) is the preparation of standards which are tailor-made to the desired irradiation and counting conditions. Frequently, there simply is not a suitable standard available commercially, or the resulting gamma spectrum is convoluted with interferences. In a recent soil analysis project, the need arose for standards which contained about 35 elements. In response, a computer spreadsheet was developed to calculate the appropriate amount of each element so that the resulting gamma spectrum is relatively free of interferences. Incorporated in the program are options for calculating all of the irradiation and counting parameters including activity produced, necessary flux/bombardment time, counting time, and appropriate source-to-detector distance. The result is multi-element standards for CNAA which have optimal concentrations. The program retains ease of use without sacrificing capability. In addition to optimized standard production, a novel soil homogenization technique was developed which is a low cost, highly efficient alternative to commercially available homogenization systems. Comparative neutron activation analysis for large scale projects has been made easier through these advancements. This paper contains details of the design and function of the NAA spreadsheet and innovative sample handling techniques. (author) 7 refs.; 5 tabs

  16. Methods for preparing comparative standards and field samples for neutron activation analysis of soil

    International Nuclear Information System (INIS)

    Glasgow, D.C.; Dyer, F.F.; Robinson, L.

    1994-01-01

    One of the more difficult problems associated with comparative neutron activation analysis (CNAA) is the preparation of standards which are tailor-made to the desired irradiation and counting conditions. Frequently, there simply is not a suitable standard available commercially, or the resulting gamma spectrum is convoluted with interferences. In a recent soil analysis project, the need arose for standards which contained about 35 elements. In response, a computer spreadsheet was developed to calculate the appropriate amount of each element so that the resulting gamma spectrum is relatively free of interferences. Incorporated in the program are options for calculating all of the irradiation and counting parameters including activity produced, necessary flux/bombardment time, counting time, and appropriate source-to-detector distance. The result is multi-element standards for CNAA which have optimal concentrations. The program retains ease of use without sacrificing capability. In addition to optimized standard production, a novel soil homogenization technique was developed which is a low cost, highly efficient alternative to commercially available homogenization systems. Comparative neutron activation analysis for large scale projects has been made easier through these advancements. This paper contains details of the design and function of the NAA spreadsheet and innovative sample handling techniques

  17. Chitosan coatings onto polyethylene terephthalate for the development of potential active packaging material

    Energy Technology Data Exchange (ETDEWEB)

    Zemljic, Lidija Fras, E-mail: lidija.fras@uni-mb.si [Laboratory for Characterization and Processing of Polymers, Faculty of Mechanical Engineering, University of Maribor, Smetanova 17, 2000 Maribor (Slovenia); Tkavc, Tina [Laboratory for Characterization and Processing of Polymers, Faculty of Mechanical Engineering, University of Maribor, Smetanova 17, 2000 Maribor (Slovenia); Vesel, Alenka [Jozef Stefan Institute, Jamova 39, 1000 Ljubljana (Slovenia); Sauperl, Olivera [Laboratory for Characterization and Processing of Polymers, Faculty of Mechanical Engineering, University of Maribor, Smetanova 17, 2000 Maribor (Slovenia)

    2013-01-15

    Highlights: Black-Right-Pointing-Pointer The adsorption/desorption of chitosan onto PET plastic film was studied. Black-Right-Pointing-Pointer Chitosan was reversible attached onto PET plastic films. Black-Right-Pointing-Pointer Antimicrobial functionalized PET may provide potential active packaging material. - Abstract: In this paper advanced surface treatment of PET plastic film is presented for introduction of antimicrobial properties as a potential application for food (as for example meat) packaging material. Adsorption/desorption of chitosan onto PET plastic film surface was studied using several analytical techniques such as: X-Ray Photoelectron Spectroscopy (XPS), ATR-FTIR spectroscopy and titrations. Kinetic desorption of chitosan from PET surface was analysed by polyelectrolyte titration and spectrophotometric Ninhydrine reaction. Standard antimicrobial test ASTM E2149-01 was performed for functionalised PET materials in order to determine their antimicrobial properties; i. e. to measure the reductions of some of the meat pathogens; such as bacteria Salmonella enterica, Campylobacter spp., Escherichia coli, Listeria monocytogenes and fungi Candida albicans.

  18. Chitosan coatings onto polyethylene terephthalate for the development of potential active packaging material

    International Nuclear Information System (INIS)

    Zemljič, Lidija Fras; Tkavc, Tina; Vesel, Alenka; Šauperl, Olivera

    2013-01-01

    Highlights: ► The adsorption/desorption of chitosan onto PET plastic film was studied. ► Chitosan was reversible attached onto PET plastic films. ► Antimicrobial functionalized PET may provide potential active packaging material. - Abstract: In this paper advanced surface treatment of PET plastic film is presented for introduction of antimicrobial properties as a potential application for food (as for example meat) packaging material. Adsorption/desorption of chitosan onto PET plastic film surface was studied using several analytical techniques such as: X-Ray Photoelectron Spectroscopy (XPS), ATR-FTIR spectroscopy and titrations. Kinetic desorption of chitosan from PET surface was analysed by polyelectrolyte titration and spectrophotometric Ninhydrine reaction. Standard antimicrobial test ASTM E2149-01 was performed for functionalised PET materials in order to determine their antimicrobial properties; i. e. to measure the reductions of some of the meat pathogens; such as bacteria Salmonella enterica, Campylobacter spp., Escherichia coli, Listeria monocytogenes and fungi Candida albicans.

  19. Determination of gold and silver in geological standard samples MGI by instrument neutron activation analysis

    International Nuclear Information System (INIS)

    Lu Huijiuan; Zhou; Yunlu

    1987-01-01

    Gold and silver in geological standard samples MGI were determined by instrument neutron activation analysis. The various interferences of nuclides were considered. Corrected factors of the geometry in different positions have been determined. Using the geological standard sample MGM and radiochemical separation neutron activation method as reference, the reliability of this method is proved. Gold content in samples is 0.4-0.009 g/t, silver content is 9-0.3 g/t. Standard deviation is less than 3.5%, the precision of the measurement is 4.8-11.6%

  20. Oxidación a alta temperatura de un acero ASTM A335 P92 en contacto con una mezcla de sales de

    OpenAIRE

    Jessica Rodríguez Pérez; Eduardo Santos Sánchez; Darío Yesid Peña Ballesteros; Anderson Sandoval Amador; Hugo Armando Estupiñán Durán

    2016-01-01

    En esta investigación se evaluó la oxidación del acero ASTM A335 P92 en una mezcla de sales 40% K2SO4 - 60% NaCl a temperaturas de 500ºC a 700ºC, a intervalos de 50°C con tiempos de exposición de 1, 3, 10, 30, 100 y 150 horas, utilizando la norma estandarizada por la Federación Europea de Corrosión. Se realizó análisis metalográfico y de dureza antes y después del ensayo para identificar el posible cambio estructural; se realizan pruebas de difracción de rayos X (DRX), microscopía electrónica...

  1. Federal environmental standards of potential importance to operations and activities at US Department of Energy sites. Draft

    Energy Technology Data Exchange (ETDEWEB)

    Fowler, K.M.; Bilyard, G.R.; Davidson, S.A.; Jonas, R.J.; Joseph, J.

    1993-06-01

    The US Department of Energy (DOE) is now engaged in a program of environmental restoration nationwide across its 45 sites. It is also bringing its facilities into compliance with environmental regulations, decontaminating and decommissioning unwanted facilities, and constructing new waste management facilities. One of the most difficult questions that DOE must face in successfully remediating its inactive waste sites, decontaminating and decommissioning its inactive facilities, and operating its waste management facilities is: ``What criteria and standards should be met?`` Acceptable standards or procedures for determining standards will assist DOE in its conduct of ongoing waste management and pending cleanup activities by helping to ensure that those activities are conducted in compliance with applicable laws and regulations and are accepted by the regulatory community and the public. This document reports on the second of three baseline activities that are being conducted as prerequisites to either the development of quantitative standards that could be used by DOE, or consistent procedures for developing such standards. The first and third baseline activities are also briefly discussed in conjunction with the second of the three activities.

  2. Training to Support Standardization and Improvement of Configuration Management Activities

    Energy Technology Data Exchange (ETDEWEB)

    Dauber, V.; Scheffer, N.; Schoenfelder, C.

    2015-07-01

    In recent years AREVA has conducted several measures to enhance the effectiveness and efficiency of configuration management-related activities within a nuclear power plant (NPP) new build as well as modernization projects, thereby further strengthening its commitment to achieving the highest level of safety in nuclear facilities. This paper describes a new training course that shall support the standardization and improvement of configuration management activities. Recommendations will be given that should be considered when designing and developing comparable training programs to support change processes within engineering units. (Author)

  3. Effect of Decay on Ultrasonic Velocity and Attenuation Measurements in Wood

    Science.gov (United States)

    Megan McGovern; Adam Senalik; George Chen; Frank C. Beall; Henrique Reis

    2013-01-01

    The percentage mass loss of loblolly pine (pinus taeda) wood cube specimens exposed to Gloeophyllum fungus (Gloeophyllum trabeum) for increasing periods of time ranging from 1 to 12 weeks was recorded after being subjected to controlled decay following ASTM International standard ASTM D 1423-99. The specimens’ corresponding volume...

  4. UV scale calibration transfer from an improved pyroelectric detector standard to field UV-A meters and 365 nm excitation sources

    Science.gov (United States)

    Eppeldauer, G. P.; Podobedov, V. B.; Cooksey, C. C.

    2017-05-01

    Calibration of the emitted radiation from UV sources peaking at 365 nm, is necessary to perform the ASTM required 1 mW/cm2 minimum irradiance in certain military material (ships, airplanes etc) tests. These UV "black lights" are applied for crack-recognition using fluorescent liquid penetrant inspection. At present, these nondestructive tests are performed using Hg-lamps. Lack of a proper standard and the different spectral responsivities of the available UV meters cause significant measurement errors even if the same UV-365 source is measured. A pyroelectric radiometer standard with spectrally flat (constant) response in the UV-VIS range has been developed to solve the problem. The response curve of this standard determined from spectral reflectance measurement, is converted into spectral irradiance responsivity with UV sources (with different peaks and distributions) without using any source standard. Using this broadband calibration method, yearly spectral calibrations for the reference UV (LED) sources and irradiance meters is not needed. Field UV sources and meters can be calibrated against the pyroelectric radiometer standard for broadband (integrated) irradiance and integrated responsivity. Using the broadband measurement procedure, the UV measurements give uniform results with significantly decreased uncertainties.

  5. European experiences of the proposed ASTM test method for crack arrest toughness of ferritic materials

    International Nuclear Information System (INIS)

    Jutla, T.; Lidbury, D.P.G.; Ziebs, J.; Zimmermann, C.

    1986-01-01

    The proposed ASTM test method for measuring the crack arrest toughness of ferritic materials using wedge-loaded, side-grooved, compact specimens was applied to three steels: A514 bridge steel, A588 bridge steel, and A533B pressure vessel steel. Five sets of results from different laboratories are discussed here. Notches were prepared by spark erosion, although root radii varied from ∝0.1-1.5 mm. Although fast fractures were successfully initiated, arrest did not occur in a significant number of cases. The results showed no obvious dependence of crack arrest toughness, K a , (determined by a static analysis) on crack initiation toughness, K 0 . It was found that K a decreases markedly with increasing crack jump distance. A limited amount of further work on smaller specimens of the A533B steel showed that lower K a values tended to be recorded. It is concluded that a number of points relating to the proposed test method and notch preparation are worthy of further consideration. It is pointed out that the proposed validity criteria may screen out lower bound data. Nevertheless, for present practical purposes, K a values may be regarded as useful in providing an estimate of arrest toughness - although not necessarily a conservative estimate. (orig./HP)

  6. Damage characterization of an ASTM A 213 grade 91 tube after 116.000 h of service in a reforming plant

    International Nuclear Information System (INIS)

    Tonti, Andrea; Lega, Daniela; Antonini, Alessandra; Romitelli, Manuela; Alvino, Antonello

    2015-01-01

    ASTM A213 T91 steel is used in power plants and petrochemical industry, for long-term service components. The improved mechanical properties of grade 91 are strictly related to its specific microstructure: a tempered martensite matrix with fine precipitates embedded in. Despite low alloy heat resistant ferritic steels, that have a well known operational experience, T91 service performances are still faintly consolidated, because this material has serviced only in a limited number of plants, since the eighties. Most of the available data were obtained by laboratory tests on relatively short term creep strength and corrosion properties. The investigations reported in this paper represent an important opportunity to describe and better evaluate the damage evolution of the grade T91 steel after more than 100000 h of exposure in severe conditions (580 °C, 18–26 bar, combustion environment). Our results suggest that the steel suffered by different damage forms, which appear on definite portions of the tube cross section. The main degradation forms observed, in fact, into the tube bulk are both the martensite recovery and the microstructural evolution. This latter promoted mostly Laves phase precipitation and coarsening. On the other hand, both the outer and the inner wall side, suffered mainly by severe oxidation/carburization. Especially on the outer surface, the massive carbide precipitation has caused an evident loss of ductility so that the mechanical properties of the tube appear appreciably reduced. - Highlights: • ASTM A213 T91 steel is used in petrochemical industry, for long-term service components. • The investigations reported an evaluation of the damage evolution of the grade T91 steel. • Our results suggest that the steel suffered both the martensite recovery and the microstructural evolution. • The outer and the inner wall side, suffered mainly by severe oxidation/carburization. • Carbide precipitation caused loss of ductility so that the

  7. Calibration of ARI QC ionisation chambers using the Australian secondary standards for activity

    International Nuclear Information System (INIS)

    Mo, L.; Van Der Gaast, H.A.; Alexiev, D.; Butcher, K.S.A.; Davies, J.

    1999-01-01

    The Secondary Standard Activity Laboratory (SSAL) in ANSTO routinely provides standardised radioactive sources, traceable activity measurements and custom source preparation services to customers. The most important activity carried out is the calibration of ionisation chambers located in the Quality Control (QC) section of Australian Radioisotopes (ARI). This ensures that their activity measurements are traceable to the Australian primary methods of standardisation. ARI QC ionisation chambers are calibrated for 99m Tc, 67 Ga, 131 I, 201 Tl and 153 Sm. The SSAL has a TPA ionisation chamber, which has been directly calibrated against a primary standard for a variety of radioactive nuclides. Calibration factors for this chamber were determined specifically for the actual volumes (5ml for 99m Tc, 131 I, 2ml for 67 Ga, 201 Tl and 3 ml for 153 Sm) and types of vial (Wheaton) which are routinely used at ARI. These calibration factors can be used to accurately measure the activity of samples prepared by ARI. The samples can subsequently be used to calibrate the QC ionisation chambers. QC ionisation chambers are re-calibrated biannually

  8. 27 CFR 21.114 - Kerosene.

    Science.gov (United States)

    2010-04-01

    ... Kerosene. (a) Distillation range. (For applicable ASTM method, see 1980 Annual Book of ASTM Standards, Part... for aviation turbine fuels and D 86-78 for distillation of petroleum products; for incorporation by reference, see § 21.6(b).) No distillate should come over below 340 °F. and none above 570 °F. (b) Flash...

  9. 49 CFR Appendix B to Part 238 - Test Methods and Performance Criteria for the Flammability and Smoke Emission Characteristics of...

    Science.gov (United States)

    2010-10-01

    ... and Products Using an Oxygen Consumption Calorimeter. (x) ASTM E 1537-99, Standard Test Method for... Furniture for Use in Public Occupancies (January, 1991). (b) Definitions. As used in this appendix— Average... specified in the table, and (b) the ASTM E 662-01 smoke generation test procedure. Testing shall be at 50 kW...

  10. From policy to practice: strategies to meet physical activity standards in YMCA afterschool programs.

    Science.gov (United States)

    Beets, Michael W; Weaver, Robert G; Moore, Justin B; Turner-McGrievy, Gabriel; Pate, Russell R; Webster, Collin; Beighle, Aaron

    2014-03-01

    In 2011, the U.S. Young Men's Christian Association (YMCA) adopted activity standards recommending that afterschool programs (ASPs) ensure all children engage in a minimum of 30 minutes of moderate to vigorous physical activity (MVPA) daily during the ASP. ASPs decide how to accomplish this standard, for which few effective strategies exist. To evaluate strategies designed to help ASPs meet the MVPA standard. Single group intervention with pretest and three follow-up measures repeated-cross-sectional design with a subsample cohort. Four large-scale YMCA ASPs, serving approximately 500 children each day. Community-based participatory development of strategies focused on modification of program schedules, professional development training, and weekly checklists to evaluate activity opportunities. Accelerometry-derived MVPA classified as meet or fail-to-meet the 30 minutes' MVPA/day standard collected over a minimum of 4 nonconsecutive days at baseline (fall 2011) and three follow-up assessments (spring 2012, fall 2012, spring 2013). Random intercept logistic regression models evaluated the probability of meeting the standard for boys and girls, separately (analyzed summer 2013). A total of 895 children (aged 5-12 years, 48.4% girls) representing 3654 daily measures were collected across the four assessments. The percentage of girls and boys meeting the MVPA standard at baseline was 13.3% and 28.0%, respectively. By spring 2013, this increased to 29.3% and 49.6%. These changes represented an increase in the odds of meeting the 30 minutes' MVPA/day standard by 1.5 (95% CI=1.1, 2.0) and 2.4 (95% CI=1.2, 4.8) for girls and boys, respectively. The strategies developed herein represent an effective approach to enhancing current practice within YMCA ASPs to achieve existing MVPA standards. Additional work is necessary to evaluate the scalability of the strategies in a larger sample of ASPs. © 2014 American Journal of Preventive Medicine Published by American Journal of

  11. Recent activities on nuclear codes and standards

    International Nuclear Information System (INIS)

    Minematsu, Akiyoshi; Ishimoto, Shozaburo; Honjin, Masao

    2000-01-01

    The technical codes and standards relating to the nuclear power stations in Japan are prepared by shapes of laws (ministerial ordinances and bulletins) issued by the government and obliged to comply with by 'the Law concerning the Regulations of Nuclear Material Substances, Nuclear Fuel Substances and Nuclear Reactors' and 'the Electricity Business Act' and of guides defined by the Nuclear Safety Commission, and further some private standards have been issued at a shape of complement of these laws and guides by receiving national recommendation. On the other hand, in the fields of electricity and heat facilities except atomic energy, simplification and feature stipulation of the national technical codes and standards was recently carried out, by which a system usable for the private standards in and out of Japan were prepared through approval of the private Japan Electrotechnical Standards and Codes Committee (JESC). As the nuclear field was now excepted from simultaneous transfer to the private standard and the standard application system, it is expected in future to realize similar transfer if possible and preparation of the private standards is now being advanced. Here were introduced on present state on technical codes and standards relating to the nuclear power generation facilities and recent trends on their private standardization. (G.K.)

  12. 24 CFR 3280.706 - Oil piping systems.

    Science.gov (United States)

    2010-04-01

    ... the Standard Specification for Seamless Copper Water Tube, ASTM B88-93, or shall comply with ASTM B280... supply connection(s) shall be rigidly anchored to a structural member within 6 inches of the supply... shall be checked for oil leaks with fuel oil of the same grade that will be burned in the appliance. No...

  13. Data Processing and Measuring System for Studying the Cooling Capacity of Quenchants

    Science.gov (United States)

    Tsaplin, S. V.; Bolychev, S. A.; Shemanaev, D. V.; Mishagin, B. S.

    2014-09-01

    A domestically produced device for determining the cooling capacity of quenchants is developed on the basis of the ISO 9001, ISO 9950, ASTM D6200-01, and ASTM D6482-01 standards. Acomparison of the results of a determination of the parameters of cooling environments obtained by means of the present device and a foreign counterpart is carried out.

  14. Sensitization Behavior of Type 409 Ferritic Stainless Steel: Confronting DL-EPR Test and Practice W of ASTM A763

    Science.gov (United States)

    Scalise, Taís Campos; de Oliveira, Mara Cristina Lopes; Sayeg, Isaac Jamil; Antunes, Renato Altobelli

    2014-06-01

    Stainless steels employed for manufacturing automotive exhaust systems must withstand severe thermal cycles, corrosive environment due to urea decomposition, and welding operations. AISI 409 ferritic stainless steel can be considered a low-cost alternative for this application. However, depending on the manufacturing conditions during welding cycles, this material can be sensitized due to the precipitation of chromium carbides at grain boundaries. In this work, the intergranular corrosion resistances of the AISI 409 ferritic stainless steel were evaluated after annealing at 300, 500, and 700 °C for 2, 4, and 6 h. Solution-annealed samples were also tested for comparison purposes. Two methodologies were used to assess the sensitization behavior of the 409 stainless steel samples: the first one was based on the ASTM A763 (practice W), while the second one was based on the double-loop electrochemical potentiodynamic reactivation test. It was possible to identify that the annealing treatment performed at 500 °C was more critical to the occurrence of intergranular corrosion.

  15. The effect of water injection on nitric oxide emissions of a gas turbine combustor burning ASTM Jet-A fuel

    Science.gov (United States)

    Marchionna, N. R.; Diehl, L. A.; Trout, A. M.

    1973-01-01

    Tests were conducted to determine the effect of water injection on oxides of nitrogen (NOx) emissions of a full annular, ram induction gas turbine combustor burning ASTM Jet-A fuel. The combustor was operated at conditions simulating sea-level takeoff and cruise conditions. Water at ambient temperature was injected into the combustor primary zone at water-fuel ratios up to 2. At an inlet-air temperature of 589 K (600 F) water injection decreased the NOx emission index at a constant exponential rate: NOx = NOx (o) e to the -15 W/F power (where W/F is the water-fuel ratio and NOx(o) indicates the value with no injection). The effect of increasing combustor inlet-air temperature was to decrease the effect of the water injection. Other operating variables such as pressure and reference Mach number did not appear to significantly affect the percent reduction in NOx. Smoke emissions were found to decrease with increasing water injection.

  16. 77 FR 66703 - Safety Standard for Infant Swings

    Science.gov (United States)

    2012-11-07

    ...;Prices of new books are listed in the first FEDERAL REGISTER issue of each #0;week. #0; #0; #0; #0;#0..., compress the airway, and result in DEATH. 2. Warning Concerning Use of Cradle Swing (Comment 2) Five... the time of the NPR. CPSC staff has continued to work with ASTM to refine the seat deflection test for...

  17. Standard Practice for Measurement of Mechanical Properties During Charged-Particle Irradiation

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1996-01-01

    1.1 This practice covers the performance of mechanical tests on materials being irradiated with charged particles. These tests are designed to simulate or provide understanding of, or both, the mechanical behavior of materials during exposure to neutron irradiation. Practices are described that govern the test material, the particle beam, the experimental technique, and the damage calculations. Reference should be made to other ASTM standards, especially Practice E 521. Procedures are described that are applicable to creep and creep rupture tests made in tension and torsion test modes. 1.2 The word simulation is used here in a broad sense to imply an approximation of the relevant neutron irradiation environment. The degree of conformity can range from poor to nearly exact. The intent is to produce a correspondence between one or more aspects of the neutron and charged particle irradiations such that fundamental relationships are established between irradiation or material parameters and the material respons...

  18. Comparison of exertion required to perform standard and active compression-decompression cardiopulmonary resuscitation.

    Science.gov (United States)

    Shultz, J J; Mianulli, M J; Gisch, T M; Coffeen, P R; Haidet, G C; Lurie, K G

    1995-02-01

    Active compression-decompression (ACD) cardiopulmonary resuscitation (CPR) utilizes a hand-held suction device with a pressure gauge that enables the operator to compress as well as actively decompress the chest. This new CPR method improves hemodynamic and ventilatory parameters when compared with standard CPR. ACD-CPR is easy to perform but may be more labor intensive. The purpose of this study was to quantify and compare the work required to perform ACD and standard CPR. Cardiopulmonary testing was performed on six basic cardiac life support- and ACD-trained St. Paul, MN fire-fighter personnel during performance of 10 min each of ACD and standard CPR on a mannequin equipped with a compression gauge. The order of CPR techniques was determined randomly with > 1 h between each study. Each CPR method was performed at 80 compressions/min (timed with a metronome), to a depth of 1.5-2 inches, and with a 50% duty cycle. Baseline cardiopulmonary measurements were similar at rest prior to performance of both CPR methods. During standard and ACD-CPR, respectively, rate-pressure product was 18.2 +/- 3.0 vs. 23.8 +/- 1.7 (x 1000, P CPR compared with standard CPR. Both methods require subanaerobic energy expenditure and can therefore be sustained for a sufficient length of time by most individuals to optimize resuscitation efforts. Due to the slightly higher work requirement, ACD-CPR may be more difficult to perform compared with standard CPR for long periods of time, particularly by individuals unaccustomed to the workload requirement of CPR, in general.

  19. New internal standard method for activation analysis and its application. Determination of Co, Ni, Rb, Sr in pepperbush by means of photon activation

    Energy Technology Data Exchange (ETDEWEB)

    Yagi, M.; Masumoto, K. (Tohoku Univ., Sendai (Japan). Lab. of Nuclear Science)

    1984-08-01

    A new internal standard method for activation analysis has been developed. In this method a suitable element present originally in the sample is used as an internal standard and the comparative standard is prepared by applying the standard addition method to the duplicated sample. The present method has the great advantages that the comparative standard spiked with the element of interest has the same matrix as the sample, and then the amount of the element to be determined in the sample can be evaluated easily by using a very simple equation even though the sample and comparative standard are irradiated separately by particles with different flux. Neither correction of the inhomogeneities of flux between the sample and comparative standard, nor that of the self-shielding effects are necessary for the present method. The usefulness of the method was examined through the determination of Co, Ni, Rb and Sr in pepperbush by means of photon activation, and the precision and accuracy of the method were proved to be valid. 29 refs.

  20. Mechanical Properties of Post Irradiation Primary Cooling Piping of Bandung Research Reactor

    International Nuclear Information System (INIS)

    Histori; Renaningsih S; Sri Nitiswati; Ari Triyadi

    2003-01-01

    Testing on primary coolant piping of research reactor Bandung have been done. Primary coolant piping were made from Al 6061-T6. The goal of this activity is to investigate the mechanical properties changes caused by aging process after 33 years in irradiated. Type of testing i.e visual examination, thickness measurement, tensile and hardness test were done. The test data shown that there was a deposit at the inside surface of pipe, thickness decreased about 0.2 mm, tensile strength is 293 MPa, yield strength is 262 MPa, while the hardness is about 83 HRE (mean value). The test data than compared with ASTM standard. As the conclusion tensile and yield strength of pipe still fulfill the ASTM requirements, except the hardness is unsignificantly less/decreased. (author)

  1. Validation of the k0 standardization method in neutron activation analysis

    International Nuclear Information System (INIS)

    Kubesova, Marie

    2009-01-01

    The goal of this work was to validate the k 0 standardization method in neutron activation analysis for use by the Nuclear Physics Institute's NAA Laboratory. The precision and accuracy of the method were examined by using two types of reference materials: the one type comprised a set of synthetic materials and served to check the implementation of k 0 standardization, the other type consisted of matrix NIST SRMs comprising various different matrices. In general, a good agreement was obtained between the results of this work and the certified values, giving evidence of the accuracy of our results. In addition, the limits were evaluated for 61 elements

  2. Fire Safety Tests for Spherical Resorcinol Formaldehyde Resin: Data Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong-Sang; Peterson, Reid A.; Schweiger, Michael J.

    2012-07-30

    A draft safety evaluation of the scenario for spherical resorcinol-formaldehyde (SRF) resin fire inside the ion exchange column was performed by the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Fire Safety organization. The result of this draft evaluation suggested a potential change of the fire safety classification for the Cesium Ion Exchange Process System (CXP) emergency elution vessels, equipment, and piping, which may be overly bounding based on the fire performance data from the manufacturer of the ion exchange resin selected for use at the WTP. To resolve this question, the fire properties of the SRF resin were measured by Southwest Research Institute (SwRI), following the American Society for Testing and Materials (ASTM) standard procedures, through a subcontract managed by Pacific Northwest National Laboratory (PNNL). For some tests, the ASTM standard procedures were not entirely appropriate or practical for the SRF resin material, so the procedures were modified and deviations from the ASTM standard procedures were noted. This report summarizes the results of fire safety tests performed and reported by SwRI. The efforts by PNNL were limited to summarizing the test results provided by SwRI into one consolidated data report. All as-received SwRI reports are attached to this report in the Appendix. Where applicable, the precision and bias of each test method, as given by each ASTM standard procedure, are included and compared with the SwRI test results of the SRF resin.

  3. Evaluation of Systemic Antioxidant Level and Oxidative Stress In Relation to Lifestyle and Disease Progression in Asthmatic Patients/ Evaluacija nivoa antioksidanasa i oksidativnog stresa u sistemu u odnosu na životni stil i progresiju bolesti kod obolelih od astme

    Directory of Open Access Journals (Sweden)

    Singh Yadav Abhay

    2016-01-01

    Full Text Available Uvod: Astma je hronično oboljenje disajnih puteva. Oksi- dativni stres čini važan deo u patogenezi astme. Ima pre­sudnu ulogu u pogoršanju bolesti i predstavlja važnu posle- dicu upale disajnih puteva.

  4. 75 FR 22219 - Update of Revised and Reaffirmed Documents Incorporated by Reference

    Science.gov (United States)

    2010-04-28

    ... Standard 2172-09; Calculation of Gross Heating Value, Relative Density, Compressibility and Theoretical... Standard C 150-07, approved May 1, 2007, Standard Specification for Portland Cement. ASTM Standard C 330-05... Standard C 595-08, approved January 1, 2008, Standard Specification for Blended Hydraulic Cements...

  5. Review of ANS-10 standards and activities

    International Nuclear Information System (INIS)

    Poetschat, G.R.

    1981-01-01

    The ANS-10 Standards Subcommittee is sponsored by the Mathematics and Computations Division of the American Nuclear Society. The scope of the ANS-10 Subcommittee includes the development of standards which will promote effective utilization and enhance the reliability of computer programs throughout the nuclear community. The intent of such standards is to improve ease of use, facilitate the exchange, and simplify the conversion of programs. These standards are to be applied during the computer program development process. The development process is the mechanism that creates special properties such as adequate documentation, verification and validation results, ease of use and portability in computer programs which improve reliability and promote effective use. ANS-10 has developed standards for Documentation of Digital Computer Programs, Programming Practices to Facilitate the Interchange of Digital Computer Programs, and Guidelines for Considering User Needs in Computer Program Development. The Documentation and Programming Practices Standards are presently being revised. ANS-10 is presently writing a new standard on verification and validation of computer programs. (orig.) [de

  6. Hydraulic activity of belite cement from class C coal fly ash. Effect of curing and admixtures

    OpenAIRE

    Goñi, S., Guerrero, A.

    2006-01-01

    [EN] The effect of curing method and a water-reducing additive on the hydraulic activity of high lime content (ASTM type C) fly ash belite cement (FABC-2-W) is reported. A class C fly ash was subjected to hydrothermal treatment and subsequent calcination to synthesize FABC. Hydraulic activity was evaluated in the cement paste over 180 days from the physically bound water content as determined by thermogravimetric analysis and the degree of hydration, in turn found with...

  7. JBK-75 microstructure specification recommendation

    International Nuclear Information System (INIS)

    Brewer, A.W.

    1977-01-01

    Since the ASTM-E-45 standard for microcleanliness is not applicable to superalloys like JBK-75 stainless steel (Modified A-286), Rocky Flats should adopt the Ladish microcleanliness standard (APML Cleanliness Classification of High Temperature Alloys Chart, 1971), as a guide for setting material acceptance specifications for JBK-75. Inclusion ratings of S-2, N-2, C-2, and M-2 should be acceptable. The microstructure should have a grain size of 5 or finer, but not smaller than 9, and microsegregation (banding) should be kept to a minimum

  8. Validation Tests of a Non-Nuclear Combined Asphalt and Soil Density Gauge

    Science.gov (United States)

    2014-04-01

    2006) and ASTM D422 (ASTM 2007) standard grain-size distribution with hydrometer analysis for dissemination of silt and clay fractions, Atterberg...Research Development Center Figure ER D C/G SL TR -14-10 50 U.S. SIEVE OPENIN3 IN INCHES U.S. STANDARD SIEVE NUMBERS HYDROMETER &; 1!1 1ŕ... HYDROMETER l ~rt. % in. 318 in. ~ 1𔃺 6 ~. l in 2 in. 1 in. !~’: in. .. ••o ;lf20 .jf30 ~0 . 60 .. oo . 200 100 I "<{ I I I I 90 \\ 80 K \\ 70 \\ q_ ’I

  9. Rare earths analysis of rock samples by instrumental neutron activation analysis, internal standard method

    International Nuclear Information System (INIS)

    Silachyov, I.

    2016-01-01

    The application of instrumental neutron activation analysis for the determination of long-lived rare earth elements (REE) in rock samples is considered in this work. Two different methods are statistically compared: the well established external standard method carried out using standard reference materials, and the internal standard method (ISM), using Fe, determined through X-ray fluorescence analysis, as an element-comparator. The ISM proved to be the more precise method for a wide range of REE contents and can be recommended for routine practice. (author)

  10. Neutron activation analysis of reference materials by the k sub 0 standardization and relative methods

    Energy Technology Data Exchange (ETDEWEB)

    Freitas, M C; Martinho, E [LNETI/ICEN, Sacavem (Portugal)

    1989-04-15

    Instrumental neutron activation analysis with the k{sub o}-standardization method was applied to eight geological, environmental and biological reference materials, including leaves, blood, fish, sediments, soils and limestone. To a first approximation, the results were normally distributed around the certified values with a standard deviation of 10%. Results obtained by using the relative method based on well characterized multi-element standards for IAEA CRM Soil-7 are reported.

  11. Embrittlement of Intercritically Reheated Coarse Grain Heat-Affected Zone of ASTM4130 Steel

    Science.gov (United States)

    Li, Liying; Han, Tao; Han, Bin

    2018-04-01

    In this investigation, a thermal welding simulation technique was used to investigate the microstructures and mechanical properties of the intercritically reheated coarse grain heat-affected zone (IR CGHAZ) of ASTM4130 steel. The effect of post weld heat treatment (PWHT) on the toughness of IR CGHAZ was also analyzed. The toughness of IR CGHAZ was measured by means of Charpy impact, and it is found that IR CGHAZ has the lowest toughness which is much lower than that of the base metal regardless of whether PWHT is applied or not. The as-welded IR CGHAZ is mainly composed of ferrite, martensite, and many blocky M-A constituents distributing along grain boundaries and subgrain boundaries in a near-connected network. Also, the prior austenite grains are still as coarse as those in the coarse grain heat-affected zone (CGHAZ). The presence of the blocky M-A constituents and the coarsened austenite grains result in the toughness deterioration of the as-welded IR CGHAZ. Most of the blocky M-A constituents are decomposed to granular bainite due to the effect of the PWHT. However, PWHT cannot refine the prior austenite grains. Thus, the low toughness of IR CGHAZ after PWHT can be attributed to two factors, i.e., the coarsened austenite grains, and the presence of the remaining M-A constituents and granular bainite, which are located at grain boundaries and subgrain boundaries in a near-connected network. The absorbed energy of the IR CGHAZ was increased by about 3.75 times, which means that the PWHT can effectively improve the toughness but it cannot be recovered to the level of base metal.

  12. Initial testing of a neutron activation analysis system by analysing standard reference materials

    International Nuclear Information System (INIS)

    Suhaimi Hamzah; Roslan Idris; Abdul Khalik Haji Wood; Che Seman Mahmood; Abdul Rahim Mohamad Noor.

    1983-01-01

    This paper describes the data acquisition and processing system in our laboratories (ND6600), the methods of activation analysis and the results obtained from our analysis of IAEA standard reference material (SL-l lake sediments and NBS coal ash 1632a). These standards were analysed in order to check the capability of the system, which was designed in such a way as to enable the user to independently collect and process data from multiple radiation detectors. (author)

  13. Use of gold and silver standards based on phenol-formalde-hyde resin in assay-activation analysis of geological samples

    International Nuclear Information System (INIS)

    Aliev, A.I.; Drynkin, V.I.; Lejpunskaya, D.I.; Nedostup, T.V.

    1976-01-01

    Using standards on phenol-formaldehyde resin base for assaying-activation analysis of geological specimens for gold and silver has bee the advantage of uniformly distributing Au and Ag in spesimens and possible preparing tablets of practically any form or size. The validity and accuracy of these standards have been studied for the cases of short irradiation. Conventional point standards were used as reference standards. The experiments carried out have shown that tablet resol standards are suitable for a mass assaying-activation analysis for gold and silver at practically any concentrations

  14. Development of a Primary Standard for Calibration of [18F]FDG Activity Measurement Systems

    International Nuclear Information System (INIS)

    Capogni, M; Felice, P De; Fazio, A; Simonelli, F; Abbas, K

    2006-01-01

    The 18 F national primary standard was developed by the INMRI-ENEA using the 4πβ Liquid Scintillation Spectrometry Method with 3 H-Standard Efficiency Tracing. Measurements were performed at JRCIspra under a scientific collaboration between the Institute for Health and Consumer Production, the Amersham Health and the National Institute for Occupational Safety and Prevention (ISPESL). The goal of the work was to calibrate, with minimum uncertainty, the INMRI-ENEA transfer standard portable well-type ionisation chamber as well as other JRC-Ispra and Amersham Health reference Ionising Chambers used for FDG activity measurement

  15. Pesticide Active Ingredient Production Industry: National Emission Standards for Hazardous Air Pollutants (NESHAP)

    Science.gov (United States)

    This action promulgates national emission standards for hazardous air pollutants (NESHAP) for the pesticide active ingredient (PAI) production source category under section 112 of the Clean Air Act as amended (CAA or Act).

  16. Quality of Standard Reference Materials for Short Time Activation Analysis

    International Nuclear Information System (INIS)

    Ismail, S.S.; Oberleitner, W.

    2003-01-01

    Some environmental reference materials (CFA-1633 b, IAEA-SL-1, SARM-1,BCR-176, Coal-1635, IAEA-SL-3, BCR-146, and SRAM-5) were analysed by short-time activation analysis. The results show that these materials can be classified in three groups, according to their activities after irradiation. The obtained results were compared in order to create a quality index for determination of short-lived nuclides at high count rates. It was found that Cfta is not a suitable standard for determining very short-lived nuclides (half-lives<1 min) because the activity it produces is 15-fold higher than that SL-3. Biological reference materials, such as SRM-1571, SRM-1573, SRM-1575, SRM-1577, IAEA-392, and IAEA-393, were also investigated by a higher counting efficiency system. The quality of this system and its well-type detector for investigating short-lived nuclides was discussed

  17. Znaczenie edukacji w terapii pacjentów z astmą oskrzelową = Importance of education in treatment of patients with asthma

    Directory of Open Access Journals (Sweden)

    Iwona Czerwińska Pawluk

    2015-01-01

      Streszczenie   Edukacja pacjentów z astmą jest jednym z elementów warunkujących osiąganie celów leczenia, a w konsekwencji poprawia jakość życia chorych. Pośród wielu czynników warunkujących skuteczność edukacji prowadzonej wobec pacjentów z chorobą przewlekłą i / lub ich opiekunów na szczególną uwagę zasługują: partnerskie relacje między lekarzem a pacjentem/ jego opiekunem, dostosowanie zakresu wiedzy w zależności do wieku, poziomu wykształcenia oraz oczekiwań pacjentów/ opiekunów.  Istotna też jest ciągłość kształcenia, mająca na celu weryfikację zdobytej wiedzy  i nabytych umiejętności.  Chory na astmę musi zaakceptować chorobę i z pełnym przekonaniem podjąć zadanie współuczestnictwa w jej leczeniu. Edukacja jest podstawą interakcji między pracownikami opieki zdrowotnej a pacjentem. Może mieć charakter edukacji bezpośredniej,  szkoleń w małych grupach, seminariów, sympozjów, konferencji, dystrybucji materiałów edukacyjnych, kampanii medialnych,  portali internetowych.   Abstract   Education of patients with asthma is one of the prerequisites for achieving the goals of treatment and consequently improves the quality of life of patients. Among the many factors determining the effectiveness of education provided to patients with chronic disease and / or their carers deserve special attention: partnerships between doctor and patient / his guardian, adjust the scope of knowledge according to age, educational level and expectations of patients / caregivers. Also important is the continuity of education, in order to verify their knowledge and acquired skills. Suffering from asthma must accept the disease and confidently take on the task of participation in its treatment. Education is the basis of the interaction between health care professionals and patients. It may be of direct education, training in small groups, seminars, symposia, conferences, distribution of educational materials, media

  18. Effect of surface acidic oxides of activated carbon on adsorption of ammonia.

    Science.gov (United States)

    Huang, Chen-Chia; Li, Hong-Song; Chen, Chien-Hung

    2008-11-30

    The influence of surface acidity of activated carbon (AC) was experimentally studied on adsorption of ammonia (NH(3)). Coconut shell-based AC was modified by various acids at different concentrations. There were five different acids employed to modified AC, which included nitric acid, sulfuric acid, hydrochloric acid, phosphoric acid, and acetic acid. Acidic functional groups on the surface of ACs were determined by a Fourier transform infrared spectrograph (FTIR) and by the Boehm titration method. Specific surface area and pore volume of the ACs were measured by a nitrogen adsorption apparatus. Adsorption amounts of NH(3) onto the ACs were measured by a dynamic adsorption system at room temperature according to the principle of the ASTM standard test method. The concentration of NH(3) in the effluent stream was monitored by a gas-detecting tube technique. Experimental results showed that adsorption amounts of NH(3) on the modified ACs were all enhanced. The ammonia adsorption amounts on various activated carbons modified by different acids are in the following order: nitric acid>sulfuric acid>acetic acid approximately phosphoric acid>hydrochloric acid. It is worth to note that the breakthrough capacity of NH(3) is linearly proportional to the amount of acidic functional groups of the ACs.

  19. Standards update -- 1995

    Energy Technology Data Exchange (ETDEWEB)

    Mason, J.D.

    1995-12-31

    What a year this has been! Not since 1986, when SGML was being finished, has there been so much activity in the SGML world. In ISO, there are new standards being completed and old ones (some of which are not really all that old) being revised. As you`ll be hearing, there is lots of SGML activity in the applications world--particularly on the Internet--and that`s causing other kinds of standards activity. WG8 divides its work into five ``Rapporteur Groups`` (or ``RGs``) for DSSSL, Font Description and Interchange, SGML, SPDL, and Hypermedia Languages. Since interest is in DSSSL, SGML, and Hypermedia Languages, the author only mentions that the other groups have been active, too. The Fronts group has been doing amendments to its standards, ISO/IEC 9541 and ISO/IEC 10036. The Fronts groups has been active in providing support for ISO/IEC 10646, the massive character coding standard that has drawn a lot of attention in the SGML world. The SPDL group has at long last finished its standard, the Standard Page Description Language (ISO/IEC 10180) and is about to publish it. More detailed discussions are given for activity in SGML, DSSSL, and Hypermedia Languages.

  20. Status of conversion of NE standards to national consensus standards

    International Nuclear Information System (INIS)

    Jennings, S.D.

    1990-06-01

    One major goal of the Nuclear Standards Program is to convert existing NE standards into national consensus standards (where possible). This means that an NE standard in the same subject area using the national consensus process. This report is a summary of the activities that have evolved to effect conversion of NE standards to national consensus standards, and the status of current conversion activities. In some cases, all requirements in an NE standard will not be incorporated into the published national consensus standard because these requirements may be considered too restrictive or too specific for broader application by the nuclear industry. If these requirements are considered necessary for nuclear reactor program applications, the program standard will be revised and issued as a supplement to the national consensus standard. The supplemental program standard will contain only those necessary requirements not reflected by the national consensus standard. Therefore, while complete conversion of program standards may not always be realized, the standards policy has been fully supported in attempting to make maximum use of the national consensus standard. 1 tab

  1. 75 FR 35265 - Safety Standard for Infant Walkers: Final Rule

    Science.gov (United States)

    2010-06-21

    ... are walking (usually 6 to 15 months old). ASTM F 977-07 defines ``walker'' as ``a mobile unit that... attached to rigid trays. The trays are fastened to bases that have wheels or casters to make them mobile.../jumping. Occupant retention--intended to prevent entrapment by setting requirements for leg openings. The...

  2. Photospheric activity of the Sun with VIRGO and GOLF. Comparison with standard activity proxies

    Science.gov (United States)

    Salabert, D.; García, R. A.; Jiménez, A.; Bertello, L.; Corsaro, E.; Pallé, P. L.

    2017-12-01

    We study the variability of solar activity using new photospheric proxies originally developed for the analysis of stellar magnetism with the CoRoT and Kepler photometric observations. These proxies were obtained by tracking the temporal modulations in the observations associated with the spots and magnetic features as the Sun rotates. We analyzed 21 yr of observations, spanning solar cycles 23 and 24, collected by the space-based photometric VIRGO and radial velocity GOLF instruments on board the SoHO satellite. We then calculated the photospheric activity proxy Sph is for each of the three VIRGO photometers and the associated Svel proxy from the radial velocity GOLF observations. Comparisons with several standard solar activity proxies sensitive to different layers of the Sun demonstrate that these new activity proxies, Sph and Svel, provide a new manner to monitor solar activity. We show that both the long- and short-term magnetic variabilities respectively associated with the 11-yr cycle and the quasi-biennial oscillation are well monitored, and that the magnetic field interaction between the subsurface, photosphere, and chromosphere of the Sun was modified between Cycle 24 and Cycle 23. Furthermore, the photometric proxies show a wavelength dependence of the response function of the solar photosphere among the three channels of the VIRGO photometers, providing inputs for the study of the stellar magnetism of Sun-like stars.

  3. Strychnos nux-vomica seeds: Pharmacognostical standardization, extraction, and antidiabetic activity

    Directory of Open Access Journals (Sweden)

    Rajesh Bhati

    2012-01-01

    Full Text Available Background: Strychnos nux-vomica, commonly known as kuchla, contains strychnine and brucine as main constituents. Minor alkaloids present in the seeds are protostrychnine, vomicine, n-oxystrychnine, pseudostrychnine, isostrychnine, chlorogenic acid, and a glycoside. Seeds are used traditionally to treat diabetes, asthma, aphrodisiac and to improve appetite. Objective: The present study was aimed to evaluate the various pharmacognostical characters and antidiabetic activity of S. nux-vomica seed. Materials and Methods: Pharmacognostical characters were performed as per the WHO guideline. Extraction was carried out in petroleum ether, chloroform, alcohol, hydroalcoholic, aqueous, and phytochemical constituents present in extracts were detected by different chemical tests. Among these extracts hydroalcoholic, aqueous extracts were evaluated for antidiabetic activity on the basis of extractive yield and phytoconstituents, in alloxan-induced diabetic rats using gliclazide as standard. Results: Various analytical values of S. nux-vomica extract were established. Phytoconstituents present in S. nux-vomica extracts were detected. Conclusion: S. nux-vomica extracts show antihyperglycemic activity in experimental animals.

  4. Impact of a product-specific reference standard for the measurement of a PEGylated rFVIII activity: the Swiss Multicentre Field Study.

    Science.gov (United States)

    Bulla, O; Poncet, A; Alberio, L; Asmis, L M; Gähler, A; Graf, L; Nagler, M; Studt, J-D; Tsakiris, D A; Fontana, P

    2017-07-01

    Measuring factor VIII (FVIII) activity can be challenging when it has been modified, such as when FVIII is pegylated to increase its circulating half-life. Use of a product-specific reference standard may help avoid this issue. Evaluate the impact of using a product-specific reference standard for measuring the FVIII activity of BAX 855 - a pegylated FVIII - in eight of Switzerland's main laboratories. Factor VIII-deficient plasma, spiked with five different concentrations of BAX 855, plus a control FVIII sample, was sent to the participating laboratories. They measured FVIII activity by using either with a one-stage (OSA) or the chromogenic assay (CA) against their local or a product-specific reference standard. When using a local reference standard, there was an overestimation of BAX 855 activity compared to the target concentrations, both with the OSA and CA. The use of a product-specific reference standard reduced this effect: mean recovery ranged from 127.7% to 213.5% using the OSA with local reference standards, compared to 110% to 183.8% with a product-specific reference standard, and from 146.3% to 182.4% using the CA with local reference standards compared to 72.7% to 103.7% with a product-specific reference standard. In this in vitro study, the type of reference standard had a major impact on the measurement of BAX 855 activity. Evaluation was more accurate and precise when using a product-specific reference standard. © 2017 John Wiley & Sons Ltd.

  5. Development of Hospital-based Data Sets as a Vehicle for Implementation of a National Electronic Health Record.

    Science.gov (United States)

    Keikha, Leila; Farajollah, Seyede Sedigheh Seied; Safdari, Reza; Ghazisaeedi, Marjan; Mohammadzadeh, Niloofar

    2018-01-01

    In developing countries such as Iran, international standards offer good sources to survey and use for appropriate planning in the domain of electronic health records (EHRs). Therefore, in this study, HL7 and ASTM standards were considered as the main sources from which to extract EHR data. The objective of this study was to propose a hospital data set for a national EHR consisting of data classes and data elements by adjusting data sets extracted from the standards and paper-based records. This comparative study was carried out in 2017 by studying the contents of the paper-based records approved by the health ministry in Iran and the international ASTM and HL7 standards in order to extract a minimum hospital data set for a national EHR. As a result of studying the standards and paper-based records, a total of 526 data elements in 174 classes were extracted. An examination of the data indicated that the highest number of extracted data came from the free text elements, both in the paper-based records and in the standards related to the administrative data. The major sources of data extracted from ASTM and HL7 were the E1384 and Hl7V.x standards, respectively. In the paper-based records, data were extracted from 19 forms sporadically. By declaring the confidentiality of information, the ASTM standards acknowledge the issue of confidentiality of information as one of the main challenges of EHR development, and propose new types of admission, such as teleconference, tele-video, and home visit, which are inevitable with the advent of new technology for providing healthcare and treating diseases. Data related to finance and insurance, which were scattered in different categories by three organizations, emerged as the financial category. Documenting the role and responsibility of the provider by adding the authenticator/signature data element was deemed essential. Not only using well-defined and standardized data, but also adapting EHR systems to the local facilities and

  6. Guidelines on Active Content and Mobile Code: Recommendations of the National Institute of Standards and Technology

    National Research Council Canada - National Science Library

    Jansen, Wayne

    2001-01-01

    .... One such category of technologies is active content. Broadly speaking, active content refers to electronic documents that, unlike past character documents based on the American Standard Code for Information Interchange (ASCII...

  7. 30 CFR 250.901 - What industry standards must your platform meet?

    Science.gov (United States)

    2010-07-01

    ...) American Petroleum Institute (API) Bulletin 2INT-DG, Interim Guidance for Design of Offshore Structures for... (RP) 2A-WSD, RP for Planning, Designing, and Constructing Fixed Offshore Platforms—Working Stress..., (incorporated by reference as specified in § 250.198); (15) American Society for Testing and Materials (ASTM...

  8. Standard practice for analysis and interpretation of physics dosimetry results for test reactors

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    This practice describes the methodology summarized in Annex Al to be used in the analysis and interpretation of physics-dosimetry results from test reactors. This practice relies on, and ties together, the application of several supporting ASTM standard practices, guides, and methods that are in various stages of completion (see Fig. 1). Support subject areas that are discussed include reactor physics calculations, dosimeter selection and analysis, exposure units, and neutron spectrum adjustment methods. This practice is directed towards the development and application of physics-dosimetrymetallurgical data obtained from test reactor irradiation experiments that are performed in support of the operation, licensing, and regulation of LWR nuclear power plants. It specifically addresses the physics-dosimetry aspects of the problem. Procedures related to the analysis, interpretation, and application of both test and power reactor physics-dosimetry-metallurgy results are addressed in Practice E 853, Practice E 560, Matrix E 706(IE), Practice E 185, Matrix E 706(IG), Guide E 900, and Method E 646

  9. High-cycle notch sensitivity of alloy steel ASTM A743 CA6NM used in hydrogenator turbine components

    Directory of Open Access Journals (Sweden)

    José Alexander Araújo

    2010-10-01

    Full Text Available The presence of notches and other stress concentrations in turbine blades and other notch hydraulic components is a current problem in engineering. It causes a reduction of endurance limit of material. In that sense, specimens of the ASTM A743 CA6NM alloy steel using in several hydrogenator turbine components was tested. The specimens were tested under uniaxial fatigue loading with a load ratio equal to -1, and the considered stress concentration factors, Kt, values, calculated with respect to net area, were 1.55, 2.04 and 2.42. In order to determine the fatigue limit for such notch type, a reduction data method by Dixon and Mood, Staircase method was used. This approach is based on the assumed target distribution of the fatigue limit. For such geometry at least 8 specimens were tested. In addition, the Peterson and Neuber’s notch fatigue factor were compared through fatigue notch reduction factor, Kf, obtained from experimental data. According to results obtained it was possible to conclude that the tested material is less sensitive to notches than the prediction of the Peterson and Neuber’s empirical models.

  10. Initial Assessment of CSA Group Niobium Boron Based Coatings on 4340 Steel

    Science.gov (United States)

    2017-07-01

    1       2.3.   ASTM  Adhesion Testing...Model  Leptoskop 2040) on each coated plate. A minimum of five (5) measurements were taken on each side of  each plate.  2.3. ASTM  Adhesion Testing...Adhesion testing was conducted in accordance with  ASTM  B571, “Standard Practice for Qualitative  Adhesion Testing of Metallic Coatings”, using Method

  11. DOE technical standards list. Department of Energy standards index

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    This document was prepared for use by personnel involved in the selection and use of DOE technical standards and other Government and non-Government standards. This TSL provides listing of current DOE technical standards, non-Government standards that have been adopted by DOE, other Government documents in which DOE has a recorded interest, and canceled DOE technical standards. Information on new DOE technical standards projects, technical standards released for coordination, recently published DOE technical standards, and activities of non-Government standards bodies that may be of interest to DOE is published monthly in Standards Actions.

  12. Status of conversion of DOE standards to non-Government standards

    Energy Technology Data Exchange (ETDEWEB)

    Moseley, H.L.

    1992-07-01

    One major goal of the DOE Technical Standards Program is to convert existing DOE standards into non-Government standards (NGS's) where possible. This means that a DOE standard may form the basis for a standards-writing committee to produce a standard in the same subject area using the non-Government standards consensus process. This report is a summary of the activities that have evolved to effect conversion of DOE standards to NGSs, and the status of current conversion activities. In some cases, all requirements in a DOE standard will not be incorporated into the published non-Government standard because these requirements may be considered too restrictive or too specific for broader application by private industry. If requirements in a DOE standard are not incorporated in a non-Government standard and the requirements are considered necessary for DOE program applications, the DOE standard will be revised and issued as a supplement to the non-Government standard. The DOE standard will contain only those necessary requirements not reflected by the non-Government standard. Therefore, while complete conversion of DOE standards may not always be realized, the Department's technical standards policy as stated in Order 1300.2A has been fully supported in attempting to make maximum use of the non-Government standard.

  13. Status of conversion of DOE standards to non-Government standards

    Energy Technology Data Exchange (ETDEWEB)

    Moseley, H.L.

    1992-07-01

    One major goal of the DOE Technical Standards Program is to convert existing DOE standards into non-Government standards (NGS`s) where possible. This means that a DOE standard may form the basis for a standards-writing committee to produce a standard in the same subject area using the non-Government standards consensus process. This report is a summary of the activities that have evolved to effect conversion of DOE standards to NGSs, and the status of current conversion activities. In some cases, all requirements in a DOE standard will not be incorporated into the published non-Government standard because these requirements may be considered too restrictive or too specific for broader application by private industry. If requirements in a DOE standard are not incorporated in a non-Government standard and the requirements are considered necessary for DOE program applications, the DOE standard will be revised and issued as a supplement to the non-Government standard. The DOE standard will contain only those necessary requirements not reflected by the non-Government standard. Therefore, while complete conversion of DOE standards may not always be realized, the Department`s technical standards policy as stated in Order 1300.2A has been fully supported in attempting to make maximum use of the non-Government standard.

  14. Material specification for ductile cast iron in the United States

    International Nuclear Information System (INIS)

    Sorenson, K.B.

    1987-01-01

    The United States currently does not have formal design criteria for qualifying ductile cast iron (DCI) transportation casks. There is also no dedicated material standard for DCI for this particular application. Recognizing the importance of a material standard for this application, Lawrence Livermore Laboratories, in a report to the NRC, recommended that steps be taken to develop an ASTM material specification suitable for spent fuel shipping containers. A draft ASTM material specification has been written and is currently in the ASTM approval process. This paper reviews the brief history of the development of the specification, the technical basis for the material properties, the ASTM approval process and the current status of the draft specification. The expected implications of having an adopted ASTM specification on the licensing process are also discussed. The relationship of fracture toughness to composition, microstructure and tensile properties has been evaluated at Sandia National Laboratories. The first main conclusion reached is that static fracture toughness is essentially decoupled from tensile properties such as yield strength, tensile strength and ductility. The significance of this finding is that tensile properties provided for in existing DCI specifications should not be used as an indicator of a material's ability to resist crack initiation. A material specification which includes fracture toughness requirements is needed to address the brittle fracture concerns. Second, static fracture toughness was found to correlate well with material microstructure; specifically, graphite nodule count or nodule spacing

  15. Work related perceived stress and muscle activity during standardized computer work among female computer users

    DEFF Research Database (Denmark)

    Larsman, P; Thorn, S; Søgaard, K

    2009-01-01

    The current study investigated the associations between work-related perceived stress and surface electromyographic (sEMG) parameters (muscle activity and muscle rest) during standardized simulated computer work (typing, editing, precision, and Stroop tasks). It was part of the European case......-control study, NEW (Neuromuscular assessment in the Elderly Worker). The present cross-sectional study was based on a questionnaire survey and sEMG measurements among Danish and Swedish female computer users aged 45 or older (n=49). The results show associations between work-related perceived stress...... and trapezius muscle activity and rest during standardized simulated computer work, and provide partial empirical support for the hypothesized pathway of stress induced muscle activity in the association between an adverse psychosocial work environment and musculoskeletal symptoms in the neck and shoulder....

  16. What expects of academies. Activity of code and standard Div. in JSME, AESJ and JEA

    International Nuclear Information System (INIS)

    Miyano, Hiroshi

    2005-01-01

    The present states of establishment activities of standards by the three academies in the title are summarized from the viewpoint of 'explanation accountability'. Their roles and directions to go forward are also summarized. To be concrete, the trends of these establishment academies of standards relating to the nuclear industry are summarized. By focusing on the three indispensable conditions (neutrality, impartiality and transparency) for the establishment academy of standards and their implementation, the verifications of these conditions and 'explanation accountability' in these three academies are described. (K. Kato)

  17. Influence of relationship water/cement upon the processing of cements with pozzolana in standard mortar

    Directory of Open Access Journals (Sweden)

    Gener Rizo, M.

    2002-03-01

    Full Text Available The processing of standard mortar is completed following different methods in accordance with the country, but they exist two fundamental tendecies, the ISO and the ASTM. The cuban norm for mechanic-physic tests is based in ISO, and so they use a constant relationship water/cement in the processing of standard mortar a great problem concerning the cement users when they tested those mixed with puzzolanes, because they don't take care of the bigger water needs of those materials. In this work we present an study of the behaviour of Pozzolanic Portland cements (PP-250 elaborates with a fix and changeable relationship water/cement, obtained starting from the fluidity of the pure Portland cement. (P-350 The results obtained shows that the mechanical resistance decreased in cement mortars PP-250 realised with changeable relationship water/cement. So we recommend the adoption of an optional procedure to elaborate a quality mortar with pozzolana cements.

    La elaboración del mortero normalizado se realiza internacionalmente por diferentes métodos, pero existen dos tendencias fundamentales, la enunciada por ISO y por ASTM. La norma cubana de ensayos físico-mecánicos de cemento se basa en la norma ISO, por lo que para la elaboración del mortero normalizado se utiliza una relación agua/cemento constante. Esto ha provocado discrepancias con los usuarios del cemento, especialmente cuando se ensayan los cementos que contienen puzolanas, ya que se plantea que no se tiene en cuenta la mayor demanda de agua de estos materiales. En el presente trabajo se presenta un estudio del comportamiento de cementos Portland Puzolánicos (PP-250 elaborados con una relación agua/ cemento fija y variable, lograda a partir de la fluidez de la pasta de cemento Portland puro (P-350. Los resultados obtenidos indican que se producen disminuciones en la resistencia mecánica en los morteros de cemento PP-250 elaborados con agua/ cemento variable y recomienda la

  18. Certification of standard reference materials employing neutron activation analysis

    International Nuclear Information System (INIS)

    Capote Rodriguez, G.; Hernandez Rivero, A.; Molina Insfran, J.; Ribeiro Guevara, S.; Santana Encinosa, C.; Perez Zayas, G.

    1997-01-01

    Neutron activation analysis (Naa) is used extensively as one of the analytical techniques in the certification of standard reference materials (Srm). Characteristics of Naa which make it valuable in this role are: accuracy; multielemental capability; ability to assess homogeneity; high sensitivity for many elements, and essentially non-destructive method. This paper reports the concentrations of thirty elements (major, minor and trace elements) in four Cuban Srm's. The samples were irradiated in a thermal neutron flux of 10 12 -10 13 neutrons.cm -2 .s -1 . The gamma-ray spectra were measured by HPGe detectors and were analysed using ACTAN program, developed in CEADEN. (author) [es

  19. Data Collection Protocols for Adhesive Testing Results Using the Materials Selection and Analysis Tool

    Science.gov (United States)

    2012-06-01

    processing envelope will also be equally broad, as the Army employs thermosetting , thermoplastic, paste, and film adhesives cured using a variety of...Testing ASTM D 1002 13 was the basis standard used for the single-lap-joint testing. Aluminum adherends ( Alloy 2024-T3) were used with dimensions of...Surface Preparation of Aluminum Alloys to Be Adhesively Bonded in Honeycomb Shelter Panels." ASTM International, West Conshohocken, PA, 2001, DOI

  20. Light Obscuration Particle Counter Fuel Contamination Limits

    Science.gov (United States)

    2015-10-08

    two methods for measuring particulate contamination by gravimetric analysis: ASTM D2276 - Standard Test Method for Particulate Contaminant in Aviation...problems with the gravimetric methods is the poor repeatability and reproducibility of the methods , ASTM D2276 has a repeatability of 0.25 mg/L and...collected failing either the particle count or the gravimetric limit, 314 of which failed both methods . 245 false negatives were recorded where the

  1. Outlook on Standardization of Alternative Vehicle Fuels

    Energy Technology Data Exchange (ETDEWEB)

    Rehnlund, B [Atrax Energi AB (Sweden)

    2008-10-15

    methane i.e. compressed natural gas (CNG) and liquefied natural gas (LNG). 6) Bio methane (biogas from anaerobic fermentation or gasification of biomass), i.e. compressed biogas (CBG) and liquefied biogas (LBG). Standardization work on alternative fuels by the following organizations/countries and organizations/regions are presented in this report: 1) APEC (Asia-Pacific Economic Cooperation) 2) ASTM (the U.S. and Canada) 3) Brazil 4) CEN (Europe) 5) India 6) ISO 7) People's Republic of China 8) South Africa 9) Thailand. The information in this report is based on information from web sites, reports and personal contacts, enriched by the author's expertise. The report is not, however, necessarily all-embracing.

  2. Outlook on Standardization of Alternative Vehicle Fuels

    Energy Technology Data Exchange (ETDEWEB)

    Rehnlund, B. [Atrax Energi AB (Sweden)

    2008-10-15

    ) Fossil methane i.e. compressed natural gas (CNG) and liquefied natural gas (LNG). 6) Bio methane (biogas from anaerobic fermentation or gasification of biomass), i.e. compressed biogas (CBG) and liquefied biogas (LBG). Standardization work on alternative fuels by the following organizations/countries and organizations/regions are presented in this report: 1) APEC (Asia-Pacific Economic Cooperation) 2) ASTM (the U.S. and Canada) 3) Brazil 4) CEN (Europe) 5) India 6) ISO 7) People's Republic of China 8) South Africa 9) Thailand. The information in this report is based on information from web sites, reports and personal contacts, enriched by the author's expertise. The report is not, however, necessarily all-embracing.

  3. Thin coating thickness determination using radioisotope-excited x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Del Castillo, Lorena A.; Calix, Virginia S.

    2001-01-01

    Three different approaches on thin coating thickness determination using a radioisotope-excited x-ray fluorescence spectrometry were demonstrated and results were compared. A standard of thin layer of gold (Au) on a nickel (Ni) substrate from the US National Bureau of Standards (with a nominal thickness of 0.300505 microns of at least 99.9% Au electrodeposited over 2 nils of Ni) on low carbon steel (1010) was analyzed using a Cd 109-excited XRF system. Au thickness computations were done using the (a) thin standard approach, (b) thick standard approach, and (c) x-ray absorption method (ASTM A754-79 1982). These three methods yielded results within the limit set by the American Society for Testing Materials (ASTM), which is +/-3%. Of the three methods, the thick standard yielded the best result with 0.124% error. (Author)

  4. The influence of modification of elastomer compositions in polyethylene oxides on their resistance to mineral oils

    Directory of Open Access Journals (Sweden)

    E. P. Uss

    2017-01-01

    Full Text Available The influence of modifying of elastomer compositions based on nitrile rubber in the medium of low molecular weight polyethylene oxide on resistance of rubbers to liquid aggressive mediawas studied. Standard hydrocarbon oils – oil ASTM №1 and ASTM №3, having a constant chemical composition and properties, were used as aggressive fluids. Resistance of elastomer compositions to standard oil was evaluated by change in weight, volume and relative compression set after keeping the samples in these oils at elevated temperatures. The influence of aggressive environment on the degree of swelling and the value of compression set of compositions modified in polyethylene oxides medium was established. It has been shown that the mass/volume of modified rubbers during aging in oil ASTM №1 reduced to a lesser degree compared to unmodified samples, which is probably due to the influence of low molecular weight polyethylene oxides for the formation of vulcanizates structure. At the same time exposure to oil ASTM №3 of elastomer compositions increases the degree of swelling of modified rubber more than unmodified, which can be due to destruction by the action of aggressive medium additional intermolecular bonds between macromolecules of polyethylene oxide and rubber, resulting in increased flexibility of the elastomeric matrix segments. It revealed that modification of rubbers in low molecular weightpolyethylene oxides facilitates preparation of rubber with low compression set after aging in standard oils at elevated temperatures.

  5. Determinations of elements in pepperbush standard reference material by neutron activation and X-ray fluorescence analyses

    International Nuclear Information System (INIS)

    Mizumoto, Yoshihiko; Okada, Takayuki; Tatsumi, Toshiya; Kusakabe, Toshio; Katsurayama, Kousuke; Iwata, Shiro.

    1988-01-01

    Elemental contents in Pepperbush standard reference material have been determined by neutron activation and X-ray fluorescence analyses. The standard samples of orchard leaves, tomato leaves, pine needles and Kale are used for the experiment. In the neutron activation analysis, gamma-ray spectra of nuclei produced by (n,γ) reaction on Pepperbush and standard samples are measured with Ge detectors. In the X-ray fluorescence analysis, the samples are excited with X-rays from X-ray tube with rhodium anode, and the characteristic X-rays from samples are measured with a proportional counter or NaI(Tl) detector. From the gamma- and X-ray intensities, the elemental contents in Pepperbush are determined. As a result, the contents of seventeen elements, such as sodium, calcium, iron, etc., in Pepperbush are determined. (author)

  6. Section for Standard and Patents - Standardization and Patents

    International Nuclear Information System (INIS)

    Wojtowicz, S.; Trechcinski, R.; Rybka, M.; Ryszkowska, A.; Wardaszko, J.

    1997-01-01

    Full text: The most important tasks of the Section in 1996 were: preparation of national standards and program of future work on standards for nuclear instrumentation and electronic equipment in nuclear engineering; organization of activities and participation in the meetings of the Commissions for Standardization No 173 Microprocessor Systems, No 266 Nuclear Instrumentation; giving opinions and expertises on national and international standards for equipment in nuclear engineering; cooperation with the Commission for Standardization No 246 Radiological Protection; control of inventiveness activity; The quality of the technical products is being improved by: a) selection of the proper types of interface systems, technical coordination and quality control; b) creation of standards at a high technical level; The Section works mainly for the Polish Committee for Standardization, the National Atomic Energy Agency, Association of Polish Electrical Engineers and Research Institutes in Poland. The activity of the Section is useful for all national institutions where backplane busses and nuclear electronic equipment is produced or used. The Section participates in the following international organizations: IEC (International Electrotechnical Commission) TC 45 (Nuclear Instrumentation); ISO/IEC Joint Technical Committee ISO/IEC JTCl SC26 (Microprocessor systems); ESONE (European Studies on Norms for Electronics); The section takes part in popularization of nuclear technology and instrumentation in the following ways: distribution of standards and technical documentation to national institutions dealing with nuclear apparatus; collecting and distributing technical information from international organizations (e.g. ESONE); organization of technical and scientific, national and international conferences (New Generation Nuclear Power Plants - September 96, QNX in Real World - January 96); participation in the technical conference organized by the Polish Committee for

  7. Development of an ASTM standard glass durability test, the Product Consistency Test (PCT), for high level radioactive waste glass

    International Nuclear Information System (INIS)

    Jantzen, C.M.; Bibler, N.E.; Beam, D.C.; Ramsey, W.G.

    1994-01-01

    The nation's first, and the world's largest, facility to immobilize high-level nuclear waste in durable borosilicate glass has started operation at the Savannah River Site (SRS) in Aiken, South Carolina. The product specifications on the glass wasteform produced in the Defense Waste Processing Facility (DWPF) required extensive characterization of the glass product before actual production began and for continued characterization during production. To aid in this characterization, a glass durability (leach) test was needed that was easily reproducible, could be performed remotely on highly radioactive samples, and could yield results rapidly. Several standard leach tests were examined with a variety of test configurations. Using existing tests as a starting point, the DWPF Product Consistency Test (PCT was developed in which crushed glass samples are exposed to 90 ± 2 degree C deionized water for seven days. Based on extensive testing, including a seven-laboratory round robin and confirmatory testing with radioactive samples, the PCT is very reproducible, yields reliable results rapidly, and can be performed in shielded cell facilities with radioactive samples

  8. 49 CFR Appendix B to Part 192 - Qualification of Pipe

    Science.gov (United States)

    2010-10-01

    ..., “Standard Specification for Carbon and Alloy Steel Pipe, Electric-Fusion-Welded for High Pressure Service at... by reference, see § 192.7). ASTM D2517—Thermosetting plastic pipe and tubing, “Standard Specification...

  9. EG type radioactive calibration standards

    International Nuclear Information System (INIS)

    1980-01-01

    EG standards are standards with a radioactive substance deposited as a solution on filtration paper and after drying sealed into a plastic disc or cylinder shaped casing. They serve the official testing of X-ray and gamma spectrometers and as test sources. The table shows the types of used radionuclides, nominal values of activity and total error of determination not exceeding +-4%. Activity of standards is calculated from the charge and the specific activity of standard solution used for the preparation of the standard. Tightness and surface contamination is measured for each standard. The manufacturer, UVVVR Praha, gives a guarantee for the given values of activity and total error of determination. (M.D.)

  10. Standard Guide for Recording Mechanical Test Data of Fiber-Reinforced Composite Materials in Databases

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This guide provides a common format for mechanical test data for composite materials for two purposes: (1) to establish data reporting requirements for test methods and ( 2) to provide information for the design of material property databases. This guide should be used in combination with Guide E 1309 which provides similar information to identify the composite material tested. 1.2 These guidelines are specific to mechanical tests of high-modulus fiber-reinforced composite materials. Types of tests considered in this guide include tension, compression, shear, flexure, open/filled hole, bearing, fracture toughness, and fatigue. The ASTM standards for which this guide was developed are listed in . The guidelines may also be useful for additional tests or materials. 1.3 This guide is the second part of a modular approach for which the first part is Guide E 1309. Guide E 1309 serves to identify the material, and this guide serves to describe mechanical testing procedures and variables and to record results....

  11. A simple method for the measurement of reflective foil emissivity

    International Nuclear Information System (INIS)

    Ballico, M. J.; Ham, E. W. M. van der

    2013-01-01

    Reflective metal foil is widely used to reduce radiative heat transfer within the roof space of buildings. Such foils are typically mass-produced by vapor-deposition of a thin metallic coating onto a variety of substrates, ranging from plastic-coated reinforced paper to 'bubble-wrap'. Although the emissivity of such surfaces is almost negligible in the thermal infrared, typically less than 0.03, an insufficiently thick metal coating, or organic contamination of the surface, can significantly increase this value. To ensure that the quality of the installed insulation is satisfactory, Australian building code AS/NZS 4201.5:1994 requires a practical agreed method for measurement of the emissivity, and the standard ASTM-E408 is implied. Unfortunately this standard is not a 'primary method' and requires the use of specified expensive apparatus and calibrated reference materials. At NMIA we have developed a simple primary technique, based on an apparatus to thermally modulate the sample and record the apparent modulation in infra-red radiance with commercially available radiation thermometers. The method achieves an absolute accuracy in the emissivity of approximately 0.004 (k=2). This paper theoretically analyses the equivalence between the thermal emissivity measured in this manner, the effective thermal emissivity in application, and the apparent emissivity measured in accordance with ASTM-E408

  12. A simple method for the measurement of reflective foil emissivity

    Science.gov (United States)

    Ballico, M. J.; van der Ham, E. W. M.

    2013-09-01

    Reflective metal foil is widely used to reduce radiative heat transfer within the roof space of buildings. Such foils are typically mass-produced by vapor-deposition of a thin metallic coating onto a variety of substrates, ranging from plastic-coated reinforced paper to "bubble-wrap". Although the emissivity of such surfaces is almost negligible in the thermal infrared, typically less than 0.03, an insufficiently thick metal coating, or organic contamination of the surface, can significantly increase this value. To ensure that the quality of the installed insulation is satisfactory, Australian building code AS/NZS 4201.5:1994 requires a practical agreed method for measurement of the emissivity, and the standard ASTM-E408 is implied. Unfortunately this standard is not a "primary method" and requires the use of specified expensive apparatus and calibrated reference materials. At NMIA we have developed a simple primary technique, based on an apparatus to thermally modulate the sample and record the apparent modulation in infra-red radiance with commercially available radiation thermometers. The method achieves an absolute accuracy in the emissivity of approximately 0.004 (k=2). This paper theoretically analyses the equivalence between the thermal emissivity measured in this manner, the effective thermal emissivity in application, and the apparent emissivity measured in accordance with ASTM-E408.

  13. Effects of fabrication practices and techniques on the corrosion and mechanical properties of Ni-Cr-Mo nickel based alloys UNS N10276, N06022, N06686, and N06625

    International Nuclear Information System (INIS)

    Hinshaw, E.B.; Crum, J.R.

    1996-01-01

    Ni-Cr-Mo alloys have excellent resistance to both oxidizing and reducing type environments; however, heat treating, surface condition, welding, and type of welding consumable can have a significant affect on the corrosion resistance and mechanical properties of these alloys. It is also important when performing standard ASTM intergranular corrosion tests on welded test coupons to make an accurate comparison of alloys being tested. A standard weld procedure and consistent post-weld sample conditioning method should be incorporated into the comparison test program. An evaluation of the effect of various fabrication practices on the corrosion resistance of the alloy was performed using accelerated corrosion tests ASTM G28B. The fabrication conditions examined were as-welded, welded-pickled, welded-annealed-pickled, welded annealed ground, welded-ground, using over matching filler metals, and various levels of heat input. In addition to fabrication techniques, the effect of ASTM G28B test duration on corrosion rates of UNS N10276, N06022, N06686, and N06625 was evaluated. ASTM G28A intergranular corrosion and mechanical testing using welded coupons of UNS N06625 were also performed to determine the affect of post-weld annealing and aging heat treatments on the corrosion resistance and mechanical properties of UNS N06625

  14. Investigation of the effects on Charpy impact characteristics by shape of pendulum striking edge

    International Nuclear Information System (INIS)

    Kawai, Toshihiko; Etoh, Mikio; Hanawa, Namio; Shibaike, Masayuki; Inoue, Kazuo.

    1983-01-01

    Charpy impact test is used versatilely and practically as the method of evaluating the toughness of metals. In Japan, usually the JIS type testing machines are used, but recently, the test with ASTM type testing machines has been often demanded for steel materials for export or for nuclear use. Accordingly, the testing machines of both types must be installed, the testing works become troublesome, and the costs of initial investment, maintenance, management and so on increase. When the standards in various countries were investigated, the stipulation on the various particulars of the testing machines was almost similar except the shape of striking edges, which are 8mm radius in ASTM and 2mm radius in other standards. Recently it was clarified that there was some difference between the impact values of high toughness steel using JIS and ASTM machines. In order to clarify the cause of this difference and to unify the shape of edges, the investigation was carried out by the working group. The investigation of the effect of the difference of edge shapes on impact values, the analysis of fracture phenomena in impact test and the consideration on the results are reported. ASTM type testing machines should not be used for mild steel when absorbed energy exceeds 10kgf-m. (Kako, I.)

  15. Standard Test Method for Impact Resistance of Monolithic Polycarbonate Sheet by Means of a Falling Weight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1995-01-01

    1.1 This test method covers the determination of the energy required to initiate failure in monolithic polycarbonate sheet material under specified conditions of impact using a free falling weight. 1.2 Two specimen types are defined as follows: 1.2.1 Type A consists of a flat plate test specimen and employs a clamped ring support. 1.2.2 Type B consists of a simply supported three-point loaded beam specimen (Fig. 1) and is recommended for use with material which can not be failed using the Type A specimen. For a maximum drop height of 6.096 m (20 ft) and a maximum drop weight of 22.68 kg (50 lb), virgin polycarbonate greater than 12.70 mm (1/2 in.) thick will probably require use of the Type B specimen. Note 1 - See also ASTM Methods: D 1709, D 2444 and D 3029. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of reg...

  16. Estabilización química de suelos expansivos de san josé de cúcuta (colombia usando cenizas volantes

    Directory of Open Access Journals (Sweden)

    Carlos Humberto Florez-Gongora

    2008-07-01

    Full Text Available It presents the results of the chemical stabilization of a zone of San Jose de Cucuta, where it have been observed some damages in light buildings as a consequence of the expansion-shrinkage of the soil because of the change in moisture. To achieve soil stabilization, it will be used as chemical additive: fly ashes, analyzing possible advantages and drawbacks. The ashes were given by Termotasajero S.A, a company of the city. The Atterberg limits carried out in agreement to the standard ASTM D 4318-95 [1], moisture measurement (ASTM D 2216, shrinkage factors of soil (ASTM D 427-93/4943-95, particle size analysis of soils (ASTM D 422-63, specific gravity ASTM D 854-92 and Proctor standard test (ASTM D-698. From de moisture data, it is possible to observe its descending behaviour. The document shows information of specific surface area according to the procedure of blue of methylene described by Santamarina [2]. It was found that the clays, in this study case, has high plasticity (CH with a cation exchange capacity until 37 meq/100 g and high magnesium (Mg content. According to the norm NSR 98 (Title H [3], the swelling potential of the clays, is from high to very high. The behavior of the plasticity index is diminishing in values that range from thirty to forty per cent, for a percentage of mixing of 30 % in volume of ashes. This behavior confirms to us the formation of hydrates by means of pozzolanic reactions with the clayey soil. It was concluded the necessity to implement analysis of X-rays diffraction (XRD and electronic microscopy to determine mineralogical exact composition and microscopic structure, which would help to confirm or to reject the nature of high expansivity

  17. Development of a Primary Standard for Calibration of [{sup 18}F]FDG Activity Measurement Systems

    Energy Technology Data Exchange (ETDEWEB)

    Capogni, M [ENEA Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti (INMRI), Centro Ricerche Casaccia, I-00060 Rome (Italy); Felice, P De [ENEA Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti (INMRI), Centro Ricerche Casaccia, I-00060 Rome (Italy); Fazio, A [ENEA Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti (INMRI), Centro Ricerche Casaccia, I-00060 Rome (Italy); Simonelli, F [Institute for Health and Consumer Protection, Joint Research Centre (JRC), European Commission, I-21020 Ispra (Vatican City State, Holy See,), Italy; D' Ursi, V [Amersham Health Srl (AH), I-13040 Saluggia (Saint Vincent and the Grenadines), Italy; Pecorale, A [Amersham Health Srl (AH), I-13040 Saluggia (Saint Vincent and the Grenadines), Italy; Giliberti, C [Istituto Superiore per la Prevenzione e la Sicurezza del Lavoro (ISPESL), I-00184 Rome (Italy); Abbas, K [Institute for Health and Consumer Protection, Joint Research Centre (JRC), European Commission, I-21020 Ispra (Vatican City State, Holy See,), Italy

    2006-05-15

    The {sup 18}F national primary standard was developed by the INMRI-ENEA using the 4{pi}{beta} Liquid Scintillation Spectrometry Method with {sup 3}H-Standard Efficiency Tracing. Measurements were performed at JRCIspra under a scientific collaboration between the Institute for Health and Consumer Production, the Amersham Health and the National Institute for Occupational Safety and Prevention (ISPESL). The goal of the work was to calibrate, with minimum uncertainty, the INMRI-ENEA transfer standard portable well-type ionisation chamber as well as other JRC-Ispra and Amersham Health reference Ionising Chambers used for FDG activity measurement.

  18. EFAM GTP-CREEP 02 - the GKSS test procedure for determining the creep crack extension of materials

    International Nuclear Information System (INIS)

    Schwalbe, K.H.

    2002-01-01

    This document describes a fracture mechanics method in procedural form for determining the creep crack extension of materials. It is based on the unified fracture mechanics test method EFAM GTP 02, the ASTM standard E 1457-98, activities of VAMAS TWA 19, and GKSS experience in creep crack extension testing. It introduces novel features such as the rate of the δ 5 crack tip opening displacement, the crack tip opening angle, and the middle cracked tension specimen. (orig.) [de

  19. Best Technical Approach for the Petroleum Quality Analysis (PQA) System

    Science.gov (United States)

    1994-08-01

    two test methods for determination of water content in a fuel. The Karl Fischer titration method (ASTM D 1744) measures for total water, both...difficult to automate. ASTM D 664, "Standard Test Method for Acid Number of Petroleum Products by Potentiometric Titration," is simple to automate...release. distribution unlimnied 13. ABSTRACT (Maximum 2C3 words) Recent U.S. militar-y operations have identified a need for improved methods of fuel and

  20. Full-Scale Accelerated Testing of Multi-axial Geogrid Stabilized Flexible Pavements

    Science.gov (United States)

    2017-06-01

    a plastic limit (PL) of 27%, and a plasticity index (PI) of 37%, as determined by ASTM D4318. According to the Unified Soil Classification System...USCS), the soil was classified as a high- plasticity clay (CH) and an A-7-6 according to the American Association of State and Highway...Testing and Materials (ASTM). 2010. Standard test methods for liquid limit, plastic limit, and plasticity index of soils . Designation: D 4318-10e1

  1. Heat treatment temperature influence on ASTM A890 GR 6A super duplex stainless steel microstructure

    International Nuclear Information System (INIS)

    Martins, Marcelo; Casteletti, Luiz Carlos

    2005-01-01

    Duplex and super duplex stainless steels are ferrous alloys with up to 26% chromium, 8% nickel, 5% molybdenum and 0.3% nitrogen, which are largely used in applications in media containing ions from the halogen family, mainly the chloride ion (Cl - ). The emergence of this material aimed at substituting Copper-Nickel alloys (Cupro-Nickel) that despite presenting good corrosion resistance, has mechanical properties quite inferior to steel properties. The metallurgy of duplex and super duplex stainless steel is complex due to high sensitiveness to sigma phase precipitation that becomes apparent, due to the temperatures they are exposed on cooling from solidification as well as from heat treatment processes. The objective of this study was to verify the influence of heat treating temperatures on the microstructure and hardness of ASTM A890/A890M Gr 6A super duplex stainless steel type. Microstructure control is of extreme importance for castings, as the chemical composition and cooling during solidification inevitably provide conditions for precipitation of sigma phase. Higher hardness in these materials is directly associated to high sigma phase concentration in the microstructure, precipitated in the ferrite/austenite interface. While heat treatment temperature during solution treatment increases, the sigma phase content in the microstructure decreases and consequently, the material hardness diminishes. When the sigma phase was completely dissolved by the heat treatment, the material hardness was influenced only due to ferrite and austenite contents in the microstructure

  2. Development of a Standard Methodology for the Quantitative Measurement of Steel Phase Transformation Kinetics and Dilation Strains Using Dilatometric Methods, QMST (TRP 0015)

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Manish Metha; Dr. Tom Oakwood

    2004-04-28

    The purpose of this collaborative project was to develop a standard practice for obtaining and archiving quantitative steel transformation kinetic data and thermal strain data. Two families of dilatometric equipment were employed to develop this standard practice for testing bar product steels. These include high-speed quenching and deformation dilatometers and Gleeble{reg_sign} thermomechanical simulation instruments. Standard measurement, data interpretation and data reporting methods were developed and defined by the cross-industry QMST Consortium members consisting of steel-manufacturers, forgers, heat-treaters, modelers, automotive and heavy vehicle OEMs along with team expert technologists from the National Labs and academia. The team designed phase transformation experiments on two selected steel grades to validate the standard practices--a medium carbon grade SAE 1050 and an alloy steel SAE 8620. A final standard practice document was developed based on the two dilatometry methods, and was submitted to and approved by ASTM (available as A1033-04). The standard practice specifies a method for measuring austenite transformation under no elastic stress or plastic deformation. These methods will be an enabler for the development and electronic archiving of a quantitative database for process modeling using computer simulation software, and will greatly assist endusers in developing accurate process and product simulations during the thermo-mechanical processing of bar and rod product steels.

  3. Cryogenic Insulation Standard Data and Methodologies Project

    Science.gov (United States)

    Summerfield, Burton; Thompson, Karen; Zeitlin, Nancy; Mullenix, Pamela; Fesmire, James; Swanger, Adam

    2015-01-01

    for applications at sub-ambient to cryogenic temperatures. A growing need for energy efficiency and cryogenic applications is creating a worldwide demand for improved thermal insulation systems for low temperatures. The need for thermal characterization of these systems and materials raises a corresponding need for insulation test standards and thermal data targeted for cryogenic-vacuum applications. Such standards have a strong correlation to energy, transportation, and environment and the advancement of new materials technologies in these areas. In conjunction with this project, two new standards on cryogenic insulation were recently published by ASTM International: C1774 and C740. Following the requirements of NPR 7120.10, Technical Standards for NASA Programs and Projects, the appropriate information in this report can be provided to the NASA Chief Engineer as input for NASA's annual report to NIST, as required by OMB Circular No. A-119, describing NASA's use of voluntary consensus standards and participation in the development of voluntary consensus standards and bodies.

  4. Fuel quality control: Five years of activity in laboratories

    International Nuclear Information System (INIS)

    Bettinelli, M.; Cimini, G.; Durello, G.; Lucchesi, P.L.

    1991-01-01

    A description of how ENEL (Italian National Electricity Board) carries out the activity of fuel quality control is given, and the results of the Round Robin circuit which has been operating for five years in laboratories regulary performing the control analyses of these products are reported. The laboratories taking part in the Round Robin circuit are 41 (out of which 35 are ENEL laboratories and 6 are owned by external companies) and they are situated throughout Italy; the controlled parameters are the following: heat of combustion (PCS), sulphur (S), vanadium (V) and asphaltenes (ASF); the adopted methods are the official ASTM or IP ones. The statistical analysis of the results has permitted, for every parameter, the calculation of the repeatability and the reproducibility which, in most cases, have turned out to be in keeping with the values provided for in the regulations. Among the collateral initiatives promoted in the framework of this Round Robin, the following are reported: preparation of standards of fuel oil with a known content of a sulphur and vanadium; expediting visits to all the ENEL laboratories participating in the RRT; publication of a handbook of the adopted analysis methods (in Italian); definition of guide-lines on the right selection of new automatic equipment

  5. Organic filler from golden apple snails shells to improve the silicone rubber insulator properties

    Science.gov (United States)

    Tepsila, Sujirat; Suksri, Amnart

    2018-02-01

    This paper investigates the effect of an addition of filler compound using golden apple snail shell as an organic filler to the silicone rubber insulator. The filler obtained from golden apple snail shell is found mostly contained calcium carbonate. The organic calcium carbonate (CaCO3) with particle size of 45, 75, 100 and 300 micron were prepared. Sample of silicone rubber that were filled with fillers were tested under ASTM D638-02a type standard for mechanical test. Also, electrical test such as I-V characteristics (ASTM D257-07) and dry arc test according to ASTM D495-14 have been performed. The results revealed that using larger particle size of organic filler obtained from the golden apple snail shell resulted to higher value of dielectric constant as well as higher dielectric strength. Also, the filler helps slow down the tracking activity at an insulator surface due to its crystals of calcium carbonate. However, when using excessive amount of filler, the sample will have a drawbacks in mechanical properties. By using agriculture waste as a filler compound, one can reduced the usage of commercial CaCO3 as an inorganic materials and to lower the investment cost to a final silicone rubber product.

  6. Water quality - Determination of tritium activity concentration - Liquid scintillation counting method (International Standard Publication ISO 9698:1989)

    International Nuclear Information System (INIS)

    Stefanik, J.

    1999-01-01

    This International Standard specifies a method for the determination of tritiated water ([ 3 H]H 2 O) activity concentration in water by liquid scintillation counting. The method is applicable to all types of water including seawater with tritium activity concentrations of up to 10 6 Bq/m 3 when using 20 ml counting vials. Below tritium activity concentrations of about 5 x 10 4 Bq/m 3[ 8], a prior enrichment step and/or the measurement of larger sample volumes can significantly improve the accuracy of the determination and lower the limit of detection. Tritium activity concentrations higher than 10 6 Bq/m 3 may be determined after appropriate dilution with distilled water of proven low tritium content. An alternative method for the determination of these higher activities involves increasing the tritium activity concentrations of the internal standard solution. The method is not applicable to the analysis of organically bound tritium; its determination requires an oxidative digestion

  7. Prediction methods for the calculation of the flammability properties of gases and vapors: CHETAH and ASTM software. Part 1. Esters and Ethers

    International Nuclear Information System (INIS)

    Gigante, L.; Dellavedova, M.; Pasturenzi, C.; Lunghi, A.; Cardillo, P.

    2008-01-01

    After the law by decree of the 12. June 2003, N 233 (ATEX Directive) and REACH regulation (Regulation EC n. 2907/2006 of the European Parliament), several industrial fields, also not chemical, need the flammability data for the substances used. Perhaps, many of these data, especially for compounds with not common uses, are not easy to collect. It would be helpful to provide prediction methods in order to calculate these data without any experimentation that sometimes results time consuming, expensive and practically impossible for all the commercial compounds. In this research the ASTM software CHETAH (CHEmical Thermodynamic And Hazard evaluation) has been used in order to compute the lower flammability limit (L i ), the limiting oxygen concentration (LOC, using nitrogen as inert gas) as a function of temperature, the adiabatic flame temperature T flame , the fundamental burning velocity (S u ), the quenching distance (Q d ), the minimum ignition energy (MIE) for esters and ethers, substances highly used in industry. [it

  8. The relation between bone demineralization, physical activity and anthropometric standards

    Directory of Open Access Journals (Sweden)

    Milena Barbosa Camara

    2017-03-01

    Full Text Available This paper aimed to verify the correlation between bone mineral density and the level of physical activity, as well as the food intake and the anthropometric parameters. It intended to analyse the bone mineral density (BMD of menopausal women through the bone densitometry test (DO in the lumbar region (L1 to L4, femoral neck and total femur, and also use Bouchard’s self-recall of daily activities; employing the food record from Buker and Stuart to dose and quantify the daily intake of calcium and vitamin D. The data were analysed via Kolmogorov-Smirnov’s test, and default value of α = 0.05 was set to compare the BMD averages. It was observed that one hundred percent of the assessed individuals had a BMD level below the average fixed by WHO: 14.4% with osteopenia and 85.6% with osteoporosis; a lower BMD in the femoral area (0.721g and the biggest loss among the sedentary ones (0.698g. It was noticed that there was a correlation between the physical activities and the BMD only when associated with anthropometric standards and the daily ingestion of vitamin D.

  9. Preservice Secondary Teachers' Conceptions from a Mathematical Modeling Activity and Connections to the Common Core State Standards

    Science.gov (United States)

    Stohlmann, Micah; Maiorca, Cathrine; Olson, Travis A.

    2015-01-01

    Mathematical modeling is an essential integrated piece of the Common Core State Standards. However, researchers have shown that mathematical modeling activities can be difficult for teachers to implement. Teachers are more likely to implement mathematical modeling activities if they have their own successful experiences with such activities. This…

  10. Coating and Interface Degradation of Coated steel, Part 2: Accelerated Laboratory Tests

    International Nuclear Information System (INIS)

    Cambier, S.M.; Frankel, G.S.

    2014-01-01

    In a previous paper, it was demonstrated that the measurement of cathodic delamination by the Scanning Kelvin Probe can assess the interface stability of poly(vinyl butyral) (PVB) coated steel after field exposure. This technique was utilized to characterize the degradation of the polymer/metal interface in several outdoor climates. In this paper, the effects of environmental factors on the interface degradation were investigated in the laboratory. The mechanisms measured in the field were reproduced to provide input in the development of an appropriate accelerated test for PVB coated steel. The ASTM B117 and G154 standardized tests were investigated individually and sequentially. The interface stability improved after 24 h of ASTM G154 exposure. After 144 h of exposure to ASTM G154 exposure, polymer oxidation took place simultaneously with interface degradation. The condensation phase of the ASTM G154 test was responsible for the interface improvement while the ultraviolet radiation triggered the interface degradation. Pre-exposure to ASTM G154 delayed wet de-adhesion during ASTM B117 exposure. After wet de-adhesion caused by 6 h of ASTM B117, exposure to ASTM G154 for 24 h increased the interface stability. The effects of ultraviolet radiation, relative humidity, temperature and environment on interface degradation were investigated in a special chamber. Humidity was the primary factor found to influence the interface improvement during G154 exposure. A wet/dry salt fog cycle with irradiation by an ultraviolet or filtered xenon arc lamp around room temperature was suggested to reproduce the competition between the interface improvement and the interface degradation that takes place in the field

  11. Accurate determination of arsenic in arsenobetaine standard solutions of BCR-626 and NMIJ CRM 7901-a by neutron activation analysis coupled with internal standard method.

    Science.gov (United States)

    Miura, Tsutomu; Chiba, Koichi; Kuroiwa, Takayoshi; Narukawa, Tomohiro; Hioki, Akiharu; Matsue, Hideaki

    2010-09-15

    Neutron activation analysis (NAA) coupled with an internal standard method was applied for the determination of As in the certified reference material (CRM) of arsenobetaine (AB) standard solutions to verify their certified values. Gold was used as an internal standard to compensate for the difference of the neutron exposure in an irradiation capsule and to improve the sample-to-sample repeatability. Application of the internal standard method significantly improved linearity of the calibration curve up to 1 microg of As, too. The analytical reliability of the proposed method was evaluated by k(0)-standardization NAA. The analytical results of As in AB standard solutions of BCR-626 and NMIJ CRM 7901-a were (499+/-55)mgkg(-1) (k=2) and (10.16+/-0.15)mgkg(-1) (k=2), respectively. These values were found to be 15-20% higher than the certified values. The between-bottle variation of BCR-626 was much larger than the expanded uncertainty of the certified value, although that of NMIJ CRM 7901-a was almost negligible. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  12. DOE technical standards list: Department of Energy standards index

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-05-01

    This Department of Energy (DOE) technical standards list (TSL) has been prepared by the Office of Nuclear Safety Policy and Standards (EH-31) on the basis of currently available technical information. Periodic updates of this TSL will be issued as additional information is received on standardization documents being issued, adopted, or canceled by DOE. This document was prepared for use by personnel involved in the selection and use of DOE technical standards and other Government and non-Government standards. This TSL provides listings of current DOE technical standards, non-Government standards that have been adopted by DOE, other standards-related documents in which DOE has a recorded interest, and canceled DOE technical standards. Information on new DOE technical standards projects, technical standards released for coordination, recently published DOE technical standards, and activities of non-Government standards bodies that may be of interest to DOE is published monthly in Standards Actions.

  13. Determinations of silicon and phosphorus in Pepperbush standard reference material by neutron activation and x-ray fluorescence methods

    International Nuclear Information System (INIS)

    Mizumoto, Yoshihiko; Nishio, Hirofumi; Hayashi, Takeshi; Kusakabe, Toshio; Iwata, Shiro.

    1987-01-01

    Silicon and phosphorus contents in Pepperbush standard reference material were determined by neutron activation and X-ray fluorescence methods. In neutron activation analysis, β-ray spectra of 32 P produced by 31 P(n,γ) 32 P reaction on Pepperbush and standard samples were measured by a low background β-ray spectrometer. In X-ray fluorescence analysis, the standard samples were prepared by mixing the Pepperbush powder with silicon dioxide and diammonium hydrogenphosphate. Characteristic X-rays from the samples were analyzed by a wavelength dispersive X-ray fluorescence spectrometer. From the β and X-ray intensities, silicon and phosphorus contents in Pepperbush were determined to be 1840 ± 80 and 1200 ± 50 μg g -1 , respectively. (author)

  14. Large-scale performance and design for construction activity erosion control best management practices.

    Science.gov (United States)

    Faucette, L B; Scholl, B; Beighley, R E; Governo, J

    2009-01-01

    The National Pollutant Discharge Elimination System (NPDES) Phase II requires construction activities to have erosion and sediment control best management practices (BMPs) designed and installed for site storm water management. Although BMPs are specified on storm water pollution prevention plans (SWPPPs) as part of the construction general permit (GP), there is little evidence in the research literature as to how BMPs perform or should be designed. The objectives of this study were to: (i) comparatively evaluate the performance of common construction activity erosion control BMPs under a standardized test method, (ii) evaluate the performance of compost erosion control blanket thickness, (iii) evaluate the performance of compost erosion control blankets (CECBs) on a variety of slope angles, and (iv) determine Universal Soil Loss Equation (USLE) cover management factors (C factors) for these BMPs to assist site designers and engineers. Twenty-three erosion control BMPs were evaluated using American Society of Testing and Materials (ASTM) D-6459, standard test method for determination of ECB performance in protecting hill slopes from rainfall induced erosion, on 4:1 (H:V), 3:1, and 2:1 slopes. Soil loss reduction for treatments exposed to 5 cm of rainfall on a 2:1 slope ranged from-7 to 99%. For rainfall exposure of 10 cm, treatment soil loss reduction ranged from 8 to 99%. The 2.5 and 5 cm CECBs significantly reduced erosion on slopes up to 2:1, while CECBs or= 4:1 when rainfall totals reach 5 cm. Based on the soil loss results, USLE C factors ranged from 0.01 to 0.9. These performance and design criteria should aid site planners and designers in decision-making processes.

  15. Investigation of Hg volatile losses from samples and standards during neutron activation analysis

    International Nuclear Information System (INIS)

    Dubinskaya, N.; Dundua, V.; Chikhladze, N.

    1979-01-01

    The losses of Hg from phenol formaldehyde resin - bound standards and hair samples in neutron activation analysis in case of their irradiation in the water filled nuclear reactor channel is studied. The mean losses of Hg during 20-30 hrs irradiation at (2-3)x10 18 n/cm 2 are 15-20% with their stopping at double Al-covers. The mean losses of Hg from standards at 200, 250 and 300 deg C are 30, 61 and 86% respectively and do not occur at 150 deg C after their 5 hour heating. The losses of Hg from hair samples packed in polyethylene tubes through the package walls in experimental conditions are not observed

  16. Validity of consumer-grade activity monitor to identify manual wheelchair propulsion in standardized activities of daily living.

    Science.gov (United States)

    Leving, Marika T; Horemans, Henricus L D; Vegter, Riemer J K; de Groot, Sonja; Bussmann, Johannes B J; van der Woude, Lucas H V

    2018-01-01

    Hypoactive lifestyle contributes to the development of secondary complications and lower quality of life in wheelchair users. There is a need for objective and user-friendly physical activity monitors for wheelchair-dependent individuals in order to increase physical activity through self-monitoring, goal setting, and feedback provision. To determine the validity of Activ8 Activity Monitors to 1) distinguish two classes of activities: independent wheelchair propulsion from other non-propulsive wheelchair-related activities 2) distinguish five wheelchair-related classes of activities differing by the movement intensity level: sitting in a wheelchair (hands may be moving but wheelchair remains stationary), maneuvering, and normal, high speed or assisted wheelchair propulsion. Sixteen able-bodied individuals performed sixteen various standardized 60s-activities of daily living. Each participant was equipped with a set of two Activ8 Professional Activity Monitors, one at the right forearm and one at the right wheel. Task classification by the Active8 Monitors was validated using video recordings. For the overall agreement, sensitivity and positive predictive value, outcomes above 90% are considered excellent, between 70 and 90% good, and below 70% unsatisfactory. Division in two classes resulted in overall agreement of 82.1%, sensitivity of 77.7% and positive predictive value of 78.2%. 84.5% of total duration of all tasks was classified identically by Activ8 and based on the video material. Division in five classes resulted in overall agreement of 56.6%, sensitivity of 52.8% and positive predictive value of 51.9%. 59.8% of total duration of all tasks was classified identically by Activ8 and based on the video material. Activ8 system proved to be suitable for distinguishing between active wheelchair propulsion and other non-propulsive wheelchair-related activities. The ability of the current system and algorithms to distinguish five various wheelchair-related activities

  17. Improving the beam quality of the neutron radiography facility using the SLOWPOKE-2 at the Royal Military College of Canada

    International Nuclear Information System (INIS)

    Lewis, W.J.; Bennett, L.G.I.; Teshima, P.

    1996-01-01

    At the SLOWPOKE-2 Facility at the Royal Military College of Canada, a neutron radiography facility has been designed and installed, and the beam quality has been improved by performing a series of radiographs using American standard for testing and materials (ASTM) E 545 indicators. Other means of determining the progress such as bubble detectors and activation foils were used. Modifications to the nosepiece of the beam tube including shielding and linings for fast neutron and gamma radiation were made. (orig.)

  18. Development of a rapid procedure for the measurement of uranium in drinking water by PERALSR spectrometry

    International Nuclear Information System (INIS)

    Duffey, J.M.; Case, F.I.; Metzger, R.L.; Jessop, B.J.; Schweitzer, G.K.

    1997-01-01

    A new method has been developed for the measurement of U in water samples by selective and quantitative extraction from DTPA solution into an extractive scintillator containing HDEHP and alpha-counting by PERALS R spectrometry. Because this method offers several advantages over the current EPA and ASTM standard test methods for U in drinking water, including speed, simplicity and isotopic information, it has been proposed as a new ASTM standard test method. Sample preparation requires from 1-4 h. Less than 0.5% of Am, Pu, Po, Ra and Th were found to extract under the prescribed conditions. Typical backgrounds are ≤ 0.01 cpm. A comparison of this method with EPA standard method 908.0 and the results of two interlaboratory test of this method are reported. (author)

  19. Ketosteroid Standardized Cissus quadrangularis L. Extract and its Anabolic Activity: Time to Look Beyond Ketosteroid?

    Science.gov (United States)

    Jadhav, Atul N; Rafiq, Mohammed; Devanathan, Rajendran; Azeemuddin, Mohammed; Anturlikar, Suryakanth D; Ahmed, Akhil; Sundaram, Ramchandran; Babu, U V; Paramesh, Rangesh

    2016-05-01

    Cissus quadrangularis (CQ) L. reported to contain 3-ketosteroids and have bone health benefits. This study aimed at establishing the relationship between the ketosteroid content and anabolic as well as bone health-promoting activities of various Cissus extracts in well-established orchidectomized (ORX) rat model. Supercritical carbon dioxide, ethyl acetate, and aqueous extracts (AE) of CQ L. were prepared and standardized for ketosteroid content by two methods used in commerce. Moreover, ketosteroid standardized extracts of this plant were evaluated for anabolic activity in rats in well-established ORX rat model. The increase in the absolute weight was appreciable in the CQ-AE treated group. Similarly, with respect to bone parameters, a similar trend was seen. The mean bone density, strength, and calcium content were found to be highest in the group treated with CQ-AE compared to groups treated with other extracts. This study reveals for the first time that 3-ketosteroids are not linked to the beneficial activities on bone and highlights the need for extensive characterization of biological active principles from CQ L. In light of the above estimation studies, we believe that current standardization of Cissus extraction "3-ketosteroids" is incorrect. We also did not find any report suggesting the presence of androgenic steroids in this plant and hence the characterization based on "3-ketosteroids" is scientifically incorrect. This study highlights the insufficient understanding of biological active principles from CQ L. and underlines the need for extensive bioactivity guided studies. Cissus quadrangularis (CQ) L. reported to contain 3.ketosteroids and have bone health benefitsWe did not find correlation between ketosteroid content obtained by conventional methods and its biological effectStudies indicate that claims of ketosteroid content need not necessarily correlate to biological effects and hence warrants extensive phytochemical characterization of biological

  20. Activity of the Atomic Energy Society of Japan for compiling the consensus standard on nuclear criticality safety control

    International Nuclear Information System (INIS)

    Yamane, Yoshihiro; Matsumoto, Tadakuni

    2003-01-01

    Activity of the Atomic Energy Society of Japan for compiling the consensus standard on nuclear criticality safety control is presented. The standard recommends an enhancement of nuclear criticality safety throughout a life cycle of facility in terms of a concept of 'barriers against criticality'. (author)

  1. 75 FR 29990 - Seamless Refined Copper Pipe and Tube From Mexico: Correction to Notice of Preliminary...

    Science.gov (United States)

    2010-05-28

    ... Materials (``ASTM'') ASTM-B42, ASTM- B68, ASTM-B75, ASTM-B88, ASTM-B88M, ASTM-B188, ASTM-B251, ASTM-B251M, ASTM-B280, ASTM-B302, ASTM-B306, ASTM-359, ASTM-B743, ASTM-B819, and ASTM-B903 specifications and...

  2. 77 FR 59178 - Seamless Refined Copper Pipe and Tube From Mexico: Final Results of Antidumping Duty New Shipper...

    Science.gov (United States)

    2012-09-26

    ... (``ASTM'') ASTM-B42, ASTM-B68, ASTM- B75, ASTM-B88, ASTM-B88M, ASTM-B188, ASTM-B251, ASTM-B251M, ASTM-B280, ASTM-B302, ASTM-B306, ASTM-359, ASTM-B743, ASTM-B819, and ASTM-B903 specifications and meeting the...

  3. Risk assessment of manual material handling activities (case study: PT BRS Standard Industry)

    Science.gov (United States)

    Deviani; Triyanti, V.

    2017-12-01

    The process of moving material manually has the potential for injury to workers. The risk of injury will increase if we do not pay attention to the working conditions. The purpose of this study is to assess and analyze the injury risk level in manual handling material activity, as well as to improve the condition. The observed manual material handling activities is pole lifting and goods loading. These activities were analyzed using Job Strain Index method, Rapid Entire Body Assessment, and Chaffin’s 2D Planar Static Model. The results show that most workers who perform almost all activities have a high level of risk level with the score of JSI and REBA exceeds 9 points. For some activities, the estimated compression forces in the lumbar area also exceed the standard limits of 3400 N. Concerning this condition, several suggestions for improvement were made, improving the composition of packing, improving body posture, and making guideline posters.

  4. Improved material specifications for unsealed roads

    CSIR Research Space (South Africa)

    Paige-Green, P

    2007-01-01

    Full Text Available countries in the southern African region. However, American Standard Test Methods (ASTM), the test methods used in other countries are often based upon the British Standard (BS) methods. The inherent differences in these test methods need to be taken...

  5. 49 CFR 571.403 - Standard No. 403; Platform lift systems for motor vehicles.

    Science.gov (United States)

    2010-10-01

    ... the mobility aid or passenger rests while being raised or lowered. Platform lift means a level change... from ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. S5.6... lifts suitable for installation on buses, school buses, and MPVs other than motor homes with a GVWR...

  6. Calibration of a detector by activation with a continuous neutron source used as a transfer standard for measuring pulsed neutron beams

    International Nuclear Information System (INIS)

    Moreno, Jose; Silva, Patricio; Birstein, Lipo; Soto, Leopoldo

    2002-01-01

    This paper presents a method for calibrating activation detectors. These detectors will be used as transfer standard in measuring neutron fluxes produced by pulsed plasma sources. A standard neutron source is used as a secondary standard. The activation detector is being shielded in order to substantially reduce detection of gamma emission coming from the source. The detector's calibration factor is obtained by considering also the standard neutron source as a free source of gamma radiation so that the measurements can be done without quickly withdrawing the neutron source as it is usually done. This will substantially simplify the traditionally established method (JM)

  7. Identifying Strategies Programs Adopt to Meet Healthy Eating and Physical Activity Standards in Afterschool Programs.

    Science.gov (United States)

    Weaver, Robert G; Moore, Justin B; Turner-McGrievy, Brie; Saunders, Ruth; Beighle, Aaron; Khan, M Mahmud; Chandler, Jessica; Brazendale, Keith; Randell, Allison; Webster, Collin; Beets, Michael W

    2017-08-01

    The YMCA of USA has adopted Healthy Eating and Physical Activity (HEPA) Standards for its afterschool programs (ASPs). Little is known about strategies YMCA ASPs are implementing to achieve Standards and these strategies' effectiveness. (1) Identify strategies implemented in YMCA ASPs and (2) evaluate the relationship between strategy implementation and meeting Standards. HEPA was measured via accelerometer (moderate-to-vigorous-physical-activity [MVPA]) and direct observation (snacks served) in 20 ASPs. Strategies were identified and mapped onto a capacity building framework ( Strategies To Enhance Practice [STEPs]). Mixed-effects regression estimated increases in HEPA outcomes as implementation increased. Model-implied estimates were calculated for high (i.e., highest implementation score achieved), moderate (median implementation score across programs), and low (lowest implementation score achieved) implementation for both HEPA separately. Programs implemented a variety of strategies identified in STEPs. For every 1-point increase in implementation score 1.45% (95% confidence interval = 0.33% to 2.55%, p ≤ .001) more girls accumulated 30 min/day of MVPA and fruits and/or vegetables were served on 0.11 more days (95% confidence interval = 0.11-0.45, p ≤ .01). Relationships between implementation and other HEPA outcomes did not reach statistical significance. Still regression estimates indicated that desserts are served on 1.94 fewer days (i.e., 0.40 vs. 2.34) in the highest implementing program than the lowest implementing program and water is served 0.73 more days (i.e., 2.37 vs. 1.64). Adopting HEPA Standards at the national level does not lead to changes in routine practice in all programs. Practical strategies that programs could adopt to more fully comply with the HEPA Standards are identified.

  8. Estudo de Procedimentos de Soldagem MIG/MAG para Aplicação de Revestimentos de Liga de Níquel Inconel 625 em Aço Estrutural ASTM A387 Gr.11

    OpenAIRE

    Cavalcante, Nathália Escóssio; Andrade, Tathiane Caminha; Pinheiro, Pedro Helton Magalhães; Miranda, Hélio Cordeiro de; Motta, Marcelo Ferreira; Aguiar, Willys Machado

    2016-01-01

    Resumo O presente trabalho objetiva o estudo de técnicas de soldagem aplicadas a reparo de componentes fabricados em aço ASTM A387 Gr.11, largamente utilizado em aplicações da indústria do petróleo e gás. Devido ao regime de trabalho e necessidade de utilização de materiais com boa resistência mecânica e à corrosão, utilizou-se como metal de adição a liga UNS N06625 (Inconel 625). O processo de soldagem utilizado foi o MIG/MAG e a técnica de soldagem aplicada foi a dupla camada. A metodologia...

  9. GPR Activities in Italy: a Review

    Science.gov (United States)

    Tosti, Fabio; Ambrosanio, Michele; Battaglia, Enzo; Bianchini Ciampoli, Luca; De Carlo, Lorenzo; Matera, Loredana; Prontera, Santo; Sileo, Maria

    2015-04-01

    Ground-penetrating radar has been increasingly played an important role over the last 15 years in Italy due to its high reliability in assisting the assessment of the built environment for civil engineering purposes, and in being used for geophysical investigations within many other fields of application. In line with this, original works involving fundamental aspects of this technique and implementing its use more practically in a number of interesting projects have been developed over years, both under a research and an enterprise point of view. This paper will endeavour to review the current status of ground-penetrating radar activities in Italy. Efforts have been devoted to single out the most interesting national research projects, both recent and ongoing, involving ground-penetrating radar in Italy, such as the ARCHEO project in the 90s, funded by the Italian Ministry for Universities, wherein a stepped frequency ultra-wide band radar suited for archaeological surveys was manufactured. In this framework, it is worth citing another important and more recent project, European Community funded, namely, ORFEUS, which started in the late 2006 with the overall aim of providing the capability to locate buried infrastructure accurately and reliably by means of a bore-head ground-penetrating radar for horizontal directional drilling. A review on the main use of this non-destructive technique in management activities of national resources and infrastructures has been also performed, ranging from the applications made by Anas S.p.A., i.e., the main management authority for the Italian road and motorway network, up to private enterprises specialized in both services providing and ground-penetrating radar manufacturing such as, to cite a few, Sineco S.p.A. and IDS Ingegneria dei Sistemi S.p.A., respectively. Current national guidelines, rules or protocols to be followed during radar surveys have been also reviewed. Unlike well-established international standards such as

  10. Preliminary evaluation of the immobilization of simulated evaporator concentrate waste in low density polyethylene by extrusion process

    International Nuclear Information System (INIS)

    Cota, Stela; Oliveira, Tania Valeria S. de; Senne Junior, Murillo; Pacheco, Graziella

    2007-01-01

    Simulated evaporator concentrate was prepared by pre-treating sodium borate with calcium hydroxide to produce an insoluble borate salt. The resultant solid waste was blended by extrusion with virgin low density polyethylene (LDPE) in the proportion of 30 wt%. Samples were prepared to evaluate homogeneity, mechanical strength and leaching behavior. The homogeneity of each sample individually and in consecutive samples was indirectly estimated by sectioning each sample in four pieces and submitting each piece to density determination (ASTM standard D-792). Mechanical strength was evaluated through determination of compressive strength (ASTM standard D-695), and the results were compared to the value for the pure polymer and with the limit established by CNEN standard NN-6.09 for cement waste products. Samples were also tested for leaching by accelerated leaching test (ASTM standard C1308). Results showed a good homogeneity. Standard deviations of the density measurements were less than 1% for a single sample and less than 6% considering 3 samples. Polymer compressive strength at yield point and at 5% and 10% strain have increased after the mixture with the simulated waste, indicating an increase on the material strength. Estimated compressive strength was above CNEN standard limit for cement waste products if 5% strain could be considered a reasonable limit to assure structural integrity of the material. Cumulated leaching fraction after 11 days of accelerated leaching test was found to be below 10%, and diffusion coefficient was estimated as 9.06 x 10 -10 cm 2 /s, with deviation of 8.3%. (author)

  11. Preliminary evaluation of the immobilization of simulated evaporator concentrate waste in low density polyethylene by extrusion process

    Energy Technology Data Exchange (ETDEWEB)

    Cota, Stela; Oliveira, Tania Valeria S. de; Senne Junior, Murillo; Pacheco, Graziella [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)]. E-mail: sdsc@cdtn.br

    2007-07-01

    Simulated evaporator concentrate was prepared by pre-treating sodium borate with calcium hydroxide to produce an insoluble borate salt. The resultant solid waste was blended by extrusion with virgin low density polyethylene (LDPE) in the proportion of 30 wt%. Samples were prepared to evaluate homogeneity, mechanical strength and leaching behavior. The homogeneity of each sample individually and in consecutive samples was indirectly estimated by sectioning each sample in four pieces and submitting each piece to density determination (ASTM standard D-792). Mechanical strength was evaluated through determination of compressive strength (ASTM standard D-695), and the results were compared to the value for the pure polymer and with the limit established by CNEN standard NN-6.09 for cement waste products. Samples were also tested for leaching by accelerated leaching test (ASTM standard C1308). Results showed a good homogeneity. Standard deviations of the density measurements were less than 1% for a single sample and less than 6% considering 3 samples. Polymer compressive strength at yield point and at 5% and 10% strain have increased after the mixture with the simulated waste, indicating an increase on the material strength. Estimated compressive strength was above CNEN standard limit for cement waste products if 5% strain could be considered a reasonable limit to assure structural integrity of the material. Cumulated leaching fraction after 11 days of accelerated leaching test was found to be below 10%, and diffusion coefficient was estimated as 9.06 x 10{sup -10} cm{sup 2}/s, with deviation of 8.3%. (author)

  12. Use of sum-peak and coincidence counting methods for activity standardization of {sup 22}Na

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, E.M. de, E-mail: estela@ird.gov.br [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Iwahara, A.; Poledna, R. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Silva, M.A.L. da [Coordenacao Geral de Instalacoes Nucleares/Comissao Nacional de Energia Nuclear, R. Gal. Severiano, 90 - Botafogo, CEP 22290-901 Rio de Janeiro (Brazil); Tauhata, L. [Fundacao Carlos Chagas Filho de Amparo a Pesquisa do Estado do Rio de Janeiro (FAPERJ), Av. Erasmo Braga, 118-6 Degree-Sign andar, CEP 20020-000 Centro, Rio de Janeiro (Brazil); Delgado, J.U. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Lopes, R.T. [Laboratorio de Instrumentacao Nuclear (LIN/PEN/COPPE/UFRJ), Caixa Postal 68509, CEP 21945-970 Rio de Janeiro (Brazil)

    2012-09-21

    A solution containing the positron emitter {sup 22}Na has been absolutely standardized using the 4{pi}{beta}-{gamma} coincidence counting method and the sum-peak spectrometry counting method. In the 4{pi}{beta}-{gamma} coincidence method two ways for the activity concentration measurements were used: gating on the 1275 keV photopeak and on the 1786 keV sum-peak where the knowledge of the {beta}{sup +}-branching ratio is required. In the sum-peak method the measurements were carried out using three experimental arrangements: the first composed by a well type 5 in. Multiplication-Sign 5 in. NaI(Tl) scintillation crystal, the second by a 3 in. Multiplication-Sign 3 in. NaI(Tl) scintillation crystal placed on the top of the first, resulting in a 4{pi} counting geometry and the third arrangement is a high purity coaxial germanium detector. The results that are obtained by these two methods are compatible within the standard uncertainty values with a coverage factor of k=2 ({approx}95% of the confidence level). This means that the sum-peak counting with its more simple experimental setup than the complex coincidence 4{pi}{beta}-{gamma} counting system gives consistent results for the activity standardization of {sup 22}Na with smaller uncertainties. Besides, the time period involved to attain the result of the standardization was quite shorter than the coincidence measurements used in this work.

  13. 29 CFR 1917.94 - Foot protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Foot protection. 1917.94 Section 1917.94 Labor Regulations... protective footwear complies with any of the following consensus standards: (i) ASTM F-2412-2005, “Standard... above consensus standards will be deemed to be in compliance with the requirements of this section. [62...

  14. 29 CFR 1915.156 - Foot protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Foot protection. 1915.156 Section 1915.156 Labor... comply with any of the following consensus standards: (i) ASTM F-2412-2005, “Standard Test Methods for... effective as protective footwear that is constructed in accordance with one of the above consensus standards...

  15. Evaluation of Intensive Care Unit Ventilators at Altitude.

    Science.gov (United States)

    Blakeman, Thomas; Rodriquez, Dario; Petro, Michael; Branson, Richard

    Devices may forgo US military air worthiness and safety testing in an attempt to expedite the availability of critical assets such as mechanical ventilators with a waiver for one-time use in extenuating circumstances. We evaluated two Intensive Care Unit (ICU) level ventilators: Drager Evita XL and Puritan Bennett (PB) 840 in an altitude chamber at sea level and altitudes of 8,000 and 16,000 feet. Altitude affected delivered tidal volumes (VTs) in volume control mode (VCV) and Pressure Regulated Volume Controlled (PRVC) mode at altitude with the Evita XL but the differences were not considered clinically important with the PB 840. Sixty-seven percent of the V T s were outside the ASTM standard of ± 10% of set V T with the Evita XL at altitude. The PB 840 did not deliver V T s that were larger than the ASTM standard up to an altitude of 16,000 feet while the majority of the delivered V T s with the Därger XL were greater than the ASTM standard. This could present a patient safety issue. Caregivers must be aware of the capabilities and limitations of ICU ventilators when utilized in a hypobaric environment in order to provide safe care. Copyright © 2017 Air Medical Journal Associates. All rights reserved.

  16. The Genomic Standards Consortium

    DEFF Research Database (Denmark)

    Field, Dawn; Amaral-Zettler, Linda; Cochrane, Guy

    2011-01-01

    Standards Consortium (GSC), an open-membership organization that drives community-based standardization activities, Here we provide a short history of the GSC, provide an overview of its range of current activities, and make a call for the scientific community to join forces to improve the quality...

  17. Standardization process for pipeline right-of-way activities: the case of TRANSPETRO's Oil Pipeline and Terminals Business Unit

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Kassandra Senra de Morais M.; Goncalves, Bruno Martins [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil). Diretoria de Terminais e Oleodutos; Almeida, Maria Fatima Ludovico de [Pontificia Universidade Catolica do Rio de Janeiro (PUC-Rio/ITUC), Rio de Janeiro, RJ (Brazil). Instituto Tecnologico

    2009-07-01

    This paper describes the experience of PETROBRAS Transporte S.A. concerning the standardization process for its pipeline right-of-way (ROW) activities. This standardization initiative has been carried out within the Oil Pipelines and Terminals Standardization Program (PRONOT), focusing on planning, standardization and implementation of all norms and corporate procedures referring to TRANSPETRO's right-of-way activities. The process promoted the integration of isolated regional initiatives, a sense of unity and the creation of a learning network consisting of 60 employees. This paper presents the last phase's results concerning implementation of corporate standards, based upon achievements of previous phases. It covers the following topics: a general view of the whole process by way of introduction; the potential of integration of recent standardization results with TRANSPETRO's corporate management tools and information systems; definition of four performance indicators and their metrics related to pipeline right-of-way management, as well as a corporate standard for the requirements for contracting services related to rights-of-way inspection, maintenance and communication; challenges, barriers and benefits perceived by the team responsible for formulating and implementing standards and procedures in TRANSPETRO's Oil Pipelines and Terminals Unit. (author)

  18. Requirements of quality standards

    International Nuclear Information System (INIS)

    Mueller, J.

    1977-01-01

    The lecture traces the development of nuclear standards, codes, and Federal regulations on quality assurance (QA) for nuclear power plants and associated facilities. The technical evolution of the last twelve years, especially in the area of nuclear technology, led to different activities and regulatory initiatives, and the present result is: several nations have their own homemade standards. The lecture discusses the former and especially current activities in standard development, and gives a description of the requirements of QA-standards used in USA and Europe, especially Western Germany. Furthermore the lecture attempts to give a comparison and an evaluation of the international quality standards from the author's viewpoint. Finally the lecture presents an outlook for the future international implications of QA-standards. There is an urgent need within the nuclear industry for simplification and standardization of QA-standards. The relationship between the various standards, and the applicability of the standards need clarification and a better transparancy. To point out these problems is the purpose of the lecture. (orig.) [de

  19. Evaluation of a Proposed Drift Reduction Technology High-Speed Wind Tunnel Testing Protocol

    Science.gov (United States)

    2009-03-01

    05: “Standard Test Method for Determining Liquid Drop Size Characteristics in a Spray Using Optical Nonimaging Light- Scattering Instruments” 15...Method for Determining Liquid Drop Size Characteris- tics in a Spray Using Optical Nonimaging Light-Scattering Instruments,” Annual Book of ASTM Standards

  20. Standardization of Tragopogon graminifolius DC. Extract Based on Phenolic Compounds and Antioxidant Activity

    Directory of Open Access Journals (Sweden)

    Mohammad Hosein Farzaei

    2014-01-01

    Full Text Available Tragopogon graminifolius DC. (TG, Compositae family, is traditionally used for the treatment of various diseases like gastrointestinal and hepatic disorders. The aim of the present study is to standardize extracts from TG used for preparation of different dosage forms in traditional Iranian medicine (TIM based on phenolic compounds. For this purpose, total phenolic content and some phenolic compounds were determined in ethanolic extracts from aerial part and root of TG by HPLC method. Furthermore, antioxidant activity was evaluated using DPPH-HPLC methods. Caffeic acid, gallic acid, ρ-coumaric acid, ferulic acid, and catechin were detected in root and aerial part of TG. ρ-Coumaric acid (6.357 ± 0.014 mg·g−1 was dominant phenolic compound in aerial part followed by ferulic acid (1.24 ± 0.018 mg·g−1. Also, ρ-coumaric acid (2.685 ± 0.031 mg·g−1 was highly abundant in root, followed by catechin (2.067 ± 0.021 mg·g−1. Antioxidant activity of root extract (460.45 ± 0.78 µg Vit.E.E·mL−1 was better than that of aerial part. Generally, phenolic compounds are one of the major constituents of TG and could be used as markers for standardization of dosage forms prepared from this plant. Also, TG demonstrated significant antioxidant activity using DPPH-HPLC method. Phenolic compounds of TG may be responsible for its marked antioxidant properties.