WorldWideScience

Sample records for astm standard activities

  1. ASTM reference radiologic digital image standards

    International Nuclear Information System (INIS)

    Wysnewski, R.; Wysnewski, D.

    1996-01-01

    ASTM Reference Radiographs have been essential in defining industry's material defect grade levels for many years. ASTM Reference Radiographs are used extensively as even the American Society for Metals Nondestructive Inspection and Quality Control Metals Handbook, Volume 11, eighth edition refers to ASTM Standard Reference Radiographs. The recently published E 1648 Standard Reference Radiographs for Examination of Aluminum Fusion Welds is a prime example of the on-going need for these references. To date, 14 Standard Reference Radiographs have been published to characterize material defects. Standard Reference Radiographs do not adequately address film-less radiologic methods. There are differences in mediums to content with. On a computer CRT defect indications appear differently when compared to indications viewed in a radiograph on a view box. Industry that uses non-film radiologic methods of inspection can be burdened with additional time and money developing internal standard reference radiologic images. These references may be deemed necessary for grading levels of product defects. Because there are no ASTM Standard Reference Radiologic data files for addressing this need in the industry, the authors of this paper suggested implementing a method for their creation under ASTM supervision. ASTM can assure continuity to those users making the transition from analog radiographic images to digital image data by swiftly addressing the requirements for reference digital image standards. The current status and possible future activities regarding a method to create digital data files is presented in this paper summary

  2. 47 CFR 90.379 - ASTM E2213-03 DSRC Standard (ASTM-DSRC Standard).

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false ASTM E2213-03 DSRC Standard (ASTM-DSRC Standard... Communications Service (dsrcs) § 90.379 ASTM E2213-03 DSRC Standard (ASTM-DSRC Standard). Roadside Units... incorporated by reference: American Society for Testing and Materials (ASTM) E2213-03, “Standard Specification...

  3. 46 CFR 163.003-3 - ASTM standard.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false ASTM standard. 163.003-3 Section 163.003-3 Shipping...: SPECIFICATIONS AND APPROVAL CONSTRUCTION Pilot Ladder § 163.003-3 ASTM standard. The following standard of the American Society for Testing and Materials (ASTM) is incorporated by reference into this subpart: ASTM D...

  4. Annual Book of ASTM Standards, Part 23: Water; Atmospheric Analysis.

    Science.gov (United States)

    American Society for Testing and Materials, Philadelphia, PA.

    Standards for water and atmospheric analysis are compiled in this segment, Part 23, of the American Society for Testing and Materials (ASTM) annual book of standards. It contains all current formally approved ASTM standard and tentative test methods, definitions, recommended practices, proposed methods, classifications, and specifications. One…

  5. The USCG/environment Canada/ASTM standards development program

    International Nuclear Information System (INIS)

    Whittaker, H.

    1992-01-01

    Environment Canada's Emergencies Engineering Division (EED) has been charged, as a result of the Public Review Panel on Tanker Safety and Marine Emergency Response report, with increased R ampersand D in marine oil spills. This activity will, of necessity, include development of standards and guidelines for the testing and/or usage of oil spill cleanup equipment. The United States Coast Guard (USCG) has been charged with implementing the provisions of the Oil Pollution Act of 1990 (OPA-90), as it pertains to marine transportation vessels and facilities. Among the provisions are requirements for vessel and facility owners and operators to develop comprehensive response plans that specifically match response resources to spill removal requirements. Meeting the response plan provisions of OPA-90 requires common standards for testing, selecting and assigning resources to anticipated response needs and objectively evaluating response plans for adequacy. In August of 1991, the USCG OPA-90 office approached ASTM to determine the feasibility of developing standards through that organizations procedures. Meetings were then held between the OPA-90 staff and members of the ASTM Committee F-20 on Hazardous Substances and Oil Spill Response. An agreement was reached to commence standards development in the areas of: Barriers, Skimmers, Treating Agents, Pumps, Beach Clean-up, Sorbents, Bioremediation, In-situ Burning, Temporary Storage Devices, Communications, Remote Sensing. It was recognized that ASTM and other organizational standards existed in several of these areas, but there were those where none were known to exist. Standards development was, therefore, expected to be a complicated and time-consuming process. Both the USCG OPA-90 and EC/EED offices required standards to be developed quickly, without subverting the ASTM process. Mechanical containment and recovery was considered to be the primary area of concern for both groups

  6. ASTM International Workshop on Standards & Measurements for Tissue Engineering Scaffolds

    Science.gov (United States)

    Simon, Carl G.; Yaszemski, Michael J.; Ratcliffe, Anthony; Tomlins, Paul; Luginbuehl, Reto; Tesk, John A.

    2016-01-01

    The “Workshop on Standards & Measurements for Tissue Engineering Scaffolds” was held on May 21, 2013 in Indianapolis, IN and was sponsored by the ASTM International (ASTM). The purpose of the workshop was to identify the highest priority items for future standards work for scaffolds used in the development and manufacture of tissue engineered medical products (TEMPs). Eighteen speakers and 78 attendees met to assess current scaffold standards and to prioritize needs for future standards. A key finding was that the ASTM TEMPs subcommittees (F04.41-46) have many active “guide” documents for educational purposes, but that few standard “test methods” or “practices” have been published. Overwhelmingly, the most clearly identified need was standards for measuring the structure of scaffolds, followed by standards for biological characterization, including in vitro testing, animal models and cell-material interactions. The third most pressing need was to develop standards for assessing the mechanical properties of scaffolds. Additional needs included standards for assessing scaffold degradation, clinical outcomes with scaffolds, effects of sterilization on scaffolds, scaffold composition and drug release from scaffolds. Discussions also highlighted the need for additional scaffold reference materials and the need to use them for measurement traceability. Finally, dialogue emphasized the needs to promote the use of standards in scaffold fabrication, characterization, and commercialization and to assess the use and impact of standards in the TEMPs community. Many scaffold standard needs have been identified and focus should now turn to generating these standards to support the use of scaffolds in TEMPs. PMID:25220952

  7. ASTM Standards for Reactor Dosimetry and Pressure Vessel Surveillance

    International Nuclear Information System (INIS)

    GRIFFIN, PATRICK J.

    1999-01-01

    The ASTM standards provide guidance and instruction on how to field and interpret reactor dosimetry. They provide a roadmap towards understanding the current ''state-of-the-art'' in reactor dosimetry, as reflected by the technical community. The consensus basis to the ASTM standards assures the user of an unbiased presentation of technical procedures and interpretations of the measurements. Some insight into the types of standards and the way in which they are organized can assist one in using them in an expeditious manner. Two example are presented to help orient new users to the breadth and interrelationship between the ASTM nuclear metrology standards. One example involves the testing of a new ''widget'' to verify the radiation hardness. The second example involves quantifying the radiation damage at a pressure vessel critical weld location through surveillance dosimetry and calculation

  8. 1991 annual book of ASTM standards

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    This book contains nuclear technology standards also features test methods and practices for solar and geotechnical energy. In the nuclear category, the primary emphasis of this volume is on analysis, dosimetry, and radiation effects in materials. Over eighty standards primarily test methods and practices are featured in this category

  9. ASTM standards associated with PWR and BWR power plant licensing, operation and surveillance

    International Nuclear Information System (INIS)

    McElroy, W.N.; McElroy, R.J.; Gold, R.; Lippincott, E.P.; Lowe, A.L. Jr.

    1994-01-01

    This paper considers ASTM Standards that are available, under revision, and are being considered in support of Pressurized Water Reactor (PWR) and Boiling Water Reactor (BWR) Nuclear Power Plant (NPP) licensing, regulation, operation, surveillance and life attainment. The current activities of ASTM Committee E10 and its Subcommittees E10.02 and current activities of ASTM Committee E10 and its Subcommittees E10.02 and E10.05 and their Task Groups (TG) are described. A very important aspect of these efforts is the preparation, revision, and balloting of standards identified in the ASTM E706 Standard on Master Matrix for Light Water Reactor (LWR) Pressure Vessel (PV) Surveillance Standards. The current version (E706-87) of the Master Matrix identifies 21 ASTM LWR physics-dosimetry-metallurgy standards for Reactor Pressure Vessel (RPV) and Support Structure (SS) surveillance programs, whereas, for the next revision 34 standards are identified. The need for national and international coordination of Standards Technology Development, Transfer and Training (STDTT) is considered in this and other Symposium papers that address specific standards related physics-dosimetry-metallurgy issues. 69 refs

  10. ASTM standards for fire debris analysis: a review.

    Science.gov (United States)

    Stauffer, Eric; Lentini, John J

    2003-03-12

    The American Society for Testing and Materials (ASTM) recently updated its standards E 1387 and E 1618 for the analysis of fire debris. The changes in the classification of ignitable liquids are presented in this review. Furthermore, a new standard on extraction of fire debris with solid phase microextraction (SPME) was released. Advantages and drawbacks of this technique are presented and discussed. Also, the standard on cleanup by acid stripping has not been reapproved. Fire debris analysts that use the standards should be aware of these changes.

  11. 47 CFR 95.1509 - ASTM E2213-03 DSRC Standard.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false ASTM E2213-03 DSRC Standard. 95.1509 Section 95... ASTM E2213-03 DSRC Standard. On-Board Units operating in the 5850-5925 MHz band shall comply with the... Materials (ASTM) E2213-03, Standard Specification for Telecommunications and Information Exchange Between...

  12. Standardization work by ASTM and DIN concerning test methods for metallic materials - comparative assessment with regard for practice

    International Nuclear Information System (INIS)

    Gerischer, K.

    1986-01-01

    The article explains the significant role of ASTM and marks out basic elements of the specification system of ASTM standards. Usefulness in practice is taken as the main criterion for the subsequent comparison of ASTM or DIN activities and procedures, and results, for standardization in the field of test methods for metallic materials. The main differences are shown to exist with regard to tropicality of test standards, presentation of useful information and background knowledge, and importance attached to formal questions. ASTM standardization work is shown to be more up-to-date, contain more information, and to be less concerned with formal matters. A closer cooperation between ASTM and DIN is strongly recommended. (orig.) [de

  13. Recommendations for fluorescence instrument qualification: the new ASTM Standard Guide.

    Science.gov (United States)

    DeRose, Paul C; Resch-Genger, Ute

    2010-03-01

    Aimed at improving quality assurance and quantitation for modern fluorescence techniques, ASTM International (ASTM) is about to release a Standard Guide for Fluorescence, reviewed here. The guide's main focus is on steady state fluorometry, for which available standards and instrument characterization procedures are discussed along with their purpose, suitability, and general instructions for use. These include the most relevant instrument properties needing qualification, such as linearity and spectral responsivity of the detection system, spectral irradiance reaching the sample, wavelength accuracy, sensitivity or limit of detection for an analyte, and day-to-day performance verification. With proper consideration of method-inherent requirements and limitations, many of these procedures and standards can be adapted to other fluorescence techniques. In addition, procedures for the determination of other relevant fluorometric quantities including fluorescence quantum yields and fluorescence lifetimes are briefly introduced. The guide is a clear and concise reference geared for users of fluorescence instrumentation at all levels of experience and is intended to aid in the ongoing standardization of fluorescence measurements.

  14. Mobile Robot and Mobile Manipulator Research Towards ASTM Standards Development.

    Science.gov (United States)

    Bostelman, Roger; Hong, Tsai; Legowik, Steven

    2016-01-01

    Performance standards for industrial mobile robots and mobile manipulators (robot arms onboard mobile robots) have only recently begun development. Low cost and standardized measurement techniques are needed to characterize system performance, compare different systems, and to determine if recalibration is required. This paper discusses work at the National Institute of Standards and Technology (NIST) and within the ASTM Committee F45 on Driverless Automatic Guided Industrial Vehicles. This includes standards for both terminology, F45.91, and for navigation performance test methods, F45.02. The paper defines terms that are being considered. Additionally, the paper describes navigation test methods that are near ballot and docking test methods being designed for consideration within F45.02. This includes the use of low cost artifacts that can provide alternatives to using relatively expensive measurement systems.

  15. Interpreting the ASTM 'content standard for digital geospatial metadata'

    Science.gov (United States)

    Nebert, Douglas D.

    1996-01-01

    ASTM and the Federal Geographic Data Committee have developed a content standard for spatial metadata to facilitate documentation, discovery, and retrieval of digital spatial data using vendor-independent terminology. Spatial metadata elements are identifiable quality and content characteristics of a data set that can be tied to a geographic location or area. Several Office of Management and Budget Circulars and initiatives have been issued that specify improved cataloguing of and accessibility to federal data holdings. An Executive Order further requires the use of the metadata content standard to document digital spatial data sets. Collection and reporting of spatial metadata for field investigations performed for the federal government is an anticipated requirement. This paper provides an overview of the draft spatial metadata content standard and a description of how the standard could be applied to investigations collecting spatially-referenced field data.

  16. The role of the American Society for Testing and Materials (ASTM) in providing standards to support reliability technology for nuclear power plants

    International Nuclear Information System (INIS)

    Steele, L.E.

    1978-01-01

    ASTM is an international society for managing the development of standards on characteristics and performance of materials, products, systems and services and the promotion of related knowledge. This paper provides on overview of ASTM, emphasizing its contribution to nuclear systems reliability. In so doing, the author, from his perspective as chairman of ASTM committee E 10 on ''Nuclear Applications and the Measurement of Radiation Effects and the Committee on Standards'', illustrates ASTM contributions to the understanding and control of radiation embrittlement of light-water reactor pressure vessels. Four major related taks are summarized and pertinent standards identified. These include: (1) surveillance practice (5 standards), (2) neutron dosimetry (8 standards), (3) specification for steels for nuclear service (7 standards) and (4) basic guidelines for thermal annealing to correct radiation embrittlement (1 standard). This illustration, a specific accomplishment using ASTM standards, is cited within the context of the broader nuclear-related activities of ASTM. (author)

  17. Method for Estimating Evaporative Potential (IM/CLO) from ASTM Standard Single Wind Velocity Measures

    Science.gov (United States)

    2016-08-10

    IM/CLO) FROM ASTM STANDARD SINGLE WIND VELOCITY MEASURES DISCLAIMER The opinions or assertions contained herein are the private views of the...USARIEM TECHNICAL REPORT T16-14 METHOD FOR ESTIMATING EVAPORATIVE POTENTIAL (IM/CLO) FROM ASTM STANDARD SINGLE WIND VELOCITY... ASTM STANDARD SINGLE WIND VELOCITY MEASURES Adam W. Potter Biophysics and Biomedical Modeling Division U.S. Army Research Institute of Environmental

  18. ASTM international workshop on standards and measurements for tissue engineering scaffolds.

    Science.gov (United States)

    Simon, Carl G; Yaszemski, Michael J; Ratcliffe, Anthony; Tomlins, Paul; Luginbuehl, Reto; Tesk, John A

    2015-07-01

    The "Workshop on Standards & Measurements for Tissue Engineering Scaffolds" was held on May 21, 2013 in Indianapolis, IN, and was sponsored by the ASTM International (ASTM). The purpose of the workshop was to identify the highest priority items for future standards work for scaffolds used in the development and manufacture of tissue engineered medical products (TEMPs). Eighteen speakers and 78 attendees met to assess current scaffold standards and to prioritize needs for future standards. A key finding was that the ASTM TEMPs subcommittees (F04.41-46) have many active "guide" documents for educational purposes, but few standard "test methods" or "practices." Overwhelmingly, the most clearly identified need was standards for measuring the structure of scaffolds, followed by standards for biological characterization, including in vitro testing, animal models and cell-material interactions. The third most pressing need was to develop standards for assessing the mechanical properties of scaffolds. Additional needs included standards for assessing scaffold degradation, clinical outcomes with scaffolds, effects of sterilization on scaffolds, scaffold composition, and drug release from scaffolds. Discussions highlighted the need for additional scaffold reference materials and the need to use them for measurement traceability. Workshop participants emphasized the need to promote the use of standards in scaffold fabrication, characterization, and commercialization. Finally, participants noted that standards would be more broadly accepted if their impact in the TEMPs community could be quantified. Many scaffold standard needs have been identified and focus is turning to generating these standards to support the use of scaffolds in TEMPs. © 2014 Wiley Periodicals, Inc.

  19. Developing the (ASTM) voluntary consensus standards required to help implement the National Energy Plan

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    The recommended guide is the first American Society for Testing and Materials (ASTM) matrix in a family of such documents that combined, will help manage the development of the ASTM standards considered necessary to implement the current National Plan for Energy Research, Development, and Demonstration. It is expected that the guide will provide a framework for standards development to complement the nation's research and development in support of critical energy needs. The recommended guide identifies the energy-critical areas that are to be developed, the master ASTM recommended guide for developing the standards required to help the National Plan, the section in which each energy-critical area is covered, and the suggested ASTM lead committee responsible for each area (fossil, solar, geothermal, conservation, fusion, and fission reactor development). A comprehensive matrix to identify the areas of need for which ASTM standards will be required to help implement the National Energy Plan is also presented

  20. HACCP: Integrating Science and Management through ASTM Standards

    Science.gov (United States)

    From a technical perspective, hazard analysis-critical control point (HACCP) evaluation may be considered a risk management tool suited to a wide range of applications. As one outcome of a symposium convened by American Society for Testing and Materials (ASTM) in August, 2005, th...

  1. 77 FR 10358 - Acceptance of ASTM F963-11 as a Mandatory Consumer Product Safety Standard

    Science.gov (United States)

    2012-02-22

    ... CONSUMER PRODUCT SAFETY COMMISSION 16 CFR Chapter II Acceptance of ASTM F963-11 as a Mandatory... have accepted the revised ASTM F963-11 standard titled, Standard Consumer Safety Specifications for Toy Safety. Pursuant to section 106 of the Consumer Product Safety Improvement Act of 2008, ASTM F963-11 will...

  2. Comparisons of ASTM standards cited in the NRC standard review plan, NUREG-0800 and related documents

    International Nuclear Information System (INIS)

    Ankrum, A.R.; Bohlander, K.L.; Gilbert, E.R.; Pawlowski, R.A.; Spiesman, J.B.

    1995-10-01

    This report provides the results of comparisons of the cited and latest versions of ASTM standards cited in the NRC Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants (NUREG 0800) and related documents. The comparisons were performed by Battelle Pacific Northwest Laboratories in support of the NRC's Standard Review Plan Update and Development Program. Significant changes to the standards, from the cited version to the latest version, are described and discussed in a tabular format for each standard. Recommendations for updating each citation in the Standard Review Plan are presented. Technical considerations and suggested changes are included for related regulatory documents (i.e., Regulatory Guides and the Code of Federal Regulations) citing the standard. The results and recommendations presented in this document have not been subjected to NRC staff review

  3. 76 FR 12370 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM...

    Science.gov (United States)

    2011-03-07

    ... Production Act of 1993--ASTM International Standards Notice is hereby given that, on February 4, 2011... seq. (``the Act''), ASTM International Standards (``ASTM'') has filed written notifications.... Specifically, ASTM has provided an updated list of current, ongoing ASTM standards activities originating...

  4. 76 FR 34252 - Notice Pursuant to the National Cooperative Research and Production Act of 1993; ASTM...

    Science.gov (United States)

    2011-06-13

    ... Production Act of 1993; ASTM International Standards Notice is hereby given that, on May 11, 2011, pursuant... seq. (``the Act''), ASTM International Standards (``ASTM'') has filed written notifications.... Specifically, ASTM has provided an updated list of current, ongoing ASTM standards activities originating...

  5. Deriving allowable properties of lumber : a practical guide for interpretation of ASTM standards

    Science.gov (United States)

    Alan Bendtsen; William L. Galligan

    1978-01-01

    The ASTM standards for establishing clear wood mechanical properties and for deriving structural grades and related allowable properties for visually graded lumber can be confusing and difficult for the uninitiated to interpret. This report provides a practical guide to using these standards for individuals not familiar with their application. Sample stress...

  6. 78 FR 1884 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM...

    Science.gov (United States)

    2013-01-09

    ... Production Act of 1993--ASTM International Standards Notice is hereby given that, on December 12, 2012... seq. (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between...

  7. 78 FR 35646 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM...

    Science.gov (United States)

    2013-06-13

    ... Production Act of 1993--ASTM International Standards Notice is hereby given that, on May 10, 2013, pursuant... seq. (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between...

  8. 77 FR 34069 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM...

    Science.gov (United States)

    2012-06-08

    ... Production Act of 1993--ASTM International Standards Notice is hereby given that, on May 11, 2012, pursuant... seq. (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between...

  9. 77 FR 61786 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM...

    Science.gov (United States)

    2012-10-11

    ... Production Act of 1993--ASTM International Standards Notice is hereby given that, on September 10, 2012... seq. (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between May...

  10. 78 FR 64248 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM...

    Science.gov (United States)

    2013-10-28

    ... Production Act of 1993--ASTM International Standards Notice is hereby given that, on September 16, 2013... seq. (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between May...

  11. 78 FR 14836 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM...

    Science.gov (United States)

    2013-03-07

    ... Production Act of 1993--ASTM International Standards Notice is hereby given that, on February 11, 2013... seq. (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between...

  12. New ASTM Standards for Nondestructive Testing of Aerospace Composites

    Science.gov (United States)

    Waller, Jess M.; Saulsberry, Regor L.

    2010-01-01

    Problem: Lack of consensus standards containing procedural detail for NDE of polymer matrix composite materials: I. Flat panel composites. II. Composite components with more complex geometries a) Pressure vessels: 1) composite overwrapped pressure vessels (COPVs). 2) composite pressure vessels (CPVs). III. Sandwich core constructions. Metal and brittle matrix composites are a possible subject of future effort.

  13. Standard guide for high-resolution gamma-ray spectrometry of soil samples. ASTM standard

    International Nuclear Information System (INIS)

    1998-12-01

    This guide is under the jurisdiction of ASTM Committee C-26 on Nuclear Fuel Cycle and is the direct responsibility of Subcommittee C26.05 on Methods of Test. The current edition was approved on Jul. 10, 1998. It was published in December 1998. Copyright American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, West Conshohocken, PA, 19428, USA. This document is available from NTIS under license from ASTM

  14. CCR+: Metadata Based Extended Personal Health Record Data Model Interoperable with the ASTM CCR Standard.

    Science.gov (United States)

    Park, Yu Rang; Yoon, Young Jo; Jang, Tae Hun; Seo, Hwa Jeong; Kim, Ju Han

    2014-01-01

    Extension of the standard model while retaining compliance with it is a challenging issue because there is currently no method for semantically or syntactically verifying an extended data model. A metadata-based extended model, named CCR+, was designed and implemented to achieve interoperability between standard and extended models. Furthermore, a multilayered validation method was devised to validate the standard and extended models. The American Society for Testing and Materials (ASTM) Community Care Record (CCR) standard was selected to evaluate the CCR+ model; two CCR and one CCR+ XML files were evaluated. In total, 188 metadata were extracted from the ASTM CCR standard; these metadata are semantically interconnected and registered in the metadata registry. An extended-data-model-specific validation file was generated from these metadata. This file can be used in a smartphone application (Health Avatar CCR+) as a part of a multilayered validation. The new CCR+ model was successfully evaluated via a patient-centric exchange scenario involving multiple hospitals, with the results supporting both syntactic and semantic interoperability between the standard CCR and extended, CCR+, model. A feasible method for delivering an extended model that complies with the standard model is presented herein. There is a great need to extend static standard models such as the ASTM CCR in various domains: the methods presented here represent an important reference for achieving interoperability between standard and extended models.

  15. 77 FR 14046 - Amended Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM...

    Science.gov (United States)

    2012-03-08

    ... Research and Production Act of 1993--ASTM International Standards Notice is hereby given that, on February..., 15 U.S.C. 4301 et seq. (``the Act''), ASTM International Standards (``ASTM'') has filed written... circumstances. Specifically, ASTM has provided an updated list of current, ongoing ASTM standards activities...

  16. Fretting-corrosion at the modular tapers interface: Inspection of standard ASTM F1875-98.

    Science.gov (United States)

    Bingley, Rachel; Martin, Alan; Manfredi, Olivia; Nejadhamzeeigilani, Mahdiyar; Oladokun, Abimbola; Beadling, Andrew Robert; Siddiqui, Sohail; Anderson, James; Thompson, Jonathan; Neville, Anne; Bryant, Michael

    2018-05-01

    Interest in the degradation mechanisms at the modular tapers interfaces has been renewed due to increased reported cases of adverse reactions to metal debris and the appearance of wear and corrosion at the modular tapers interfaces at revision. Over the past two decades, a lot of research has been expended to understand the degradation mechanisms, with two primary implant loading procedures and orientations used consistently across the literature. ASTM F1875-98 is often used as a guide to understand and benchmark the tribocorrosion processes occurring within the modular tapers interface. This article presents a comparison of the two methods outlined in ASTM F1875-98 as well as a critique of the standard considering the current paradigm in pre-clinical assessment of modular tapers.

  17. Systematic Approach to Design Tailor Made Fuel Blends That Meets ASTM Standards

    DEFF Research Database (Denmark)

    Intikhab, S.; Kalakul, Sawitree; H., Choudhury

    2015-01-01

    point, vapor pressure, and heat content were determined using analytical instruments according to their respective American Society for Testing and Materials (ASTM) standards. Most of the properties complied well with the industry standards. However, model gasoline had a comparatively low RVP....... On the other hand, model diesel had a significantly higher cloud point and pour point than what is recommended. This deviation will have an impact on the cold flow properties of the fuels. For both fuels, different additives along with their composition have also been determined using the same computational...

  18. ASTM and VAMAS activities in titanium matrix composites test methods development

    Science.gov (United States)

    Johnson, W. S.; Harmon, D. M.; Bartolotta, P. A.; Russ, S. M.

    1994-01-01

    Titanium matrix composites (TMC's) are being considered for a number of aerospace applications ranging from high performance engine components to airframe structures in areas that require high stiffness to weight ratios at temperatures up to 400 C. TMC's exhibit unique mechanical behavior due to fiber-matrix interface failures, matrix cracks bridged by fibers, thermo-viscoplastic behavior of the matrix at elevated temperatures, and the development of significant thermal residual stresses in the composite due to fabrication. Standard testing methodology must be developed to reflect the uniqueness of this type of material systems. The purpose of this paper is to review the current activities in ASTM and Versailles Project on Advanced Materials and Standards (VAMAS) that are directed toward the development of standard test methodology for titanium matrix composites.

  19. Standard specification for tantalum and tantalum alloy plate, sheet, and strip. ASTM standard

    International Nuclear Information System (INIS)

    1998-09-01

    This specification is under the jurisdiction of ASTM Committee B-10 on Reactive and Refractory Metals and Alloys and is the direct responsibility of Subcommittee B10.03 on Niobium and Tantalum. Current edition approved May 10, 1998 and published September 1998. Originally published as B 708-82. Last previous edition was B 708-92

  20. 75 FR 11196 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM International

    Science.gov (United States)

    2010-03-10

    ... Production Act of 1993--ASTM International Notice is hereby given that, on February 16, 2010, pursuant to.... (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with the..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between May...

  1. 75 FR 65657 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM International

    Science.gov (United States)

    2010-10-26

    ... Production Act of 1993--ASTM International Notice is hereby given that, on September 23, 2010, pursuant to.... (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with the..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between May...

  2. 76 FR 63658 - Notice Pursuant to the National Cooperative Research and Production Act of 1993; ASTM International

    Science.gov (United States)

    2011-10-13

    ... Production Act of 1993; ASTM International Notice is hereby given that, on August 31, 2011, pursuant to.... (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with the..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between May...

  3. 77 FR 1085 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM International

    Science.gov (United States)

    2012-01-09

    ... Production Act of 1993--ASTM International Notice is hereby given that, on December 5, 2011, pursuant to.... (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with the..., ASTM has provided an updated list of current, ongoing ASTM standards activities originating between...

  4. Development of ASTM Standard for SiC-SiC Joint Testing Final Scientific/Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Jacobsen, George [General Atomics, San Diego, CA (United States); Back, Christina [General Atomics, San Diego, CA (United States)

    2015-10-30

    As the nuclear industry moves to advanced ceramic based materials for cladding and core structural materials for a variety of advanced reactors, new standards and test methods are required for material development and licensing purposes. For example, General Atomics (GA) is actively developing silicon carbide (SiC) based composite cladding (SiC-SiC) for its Energy Multiplier Module (EM2), a high efficiency gas cooled fast reactor. Through DOE funding via the advanced reactor concept program, GA developed a new test method for the nominal joint strength of an endplug sealed to advanced ceramic tubes, Fig. 1-1, at ambient and elevated temperatures called the endplug pushout (EPPO) test. This test utilizes widely available universal mechanical testers coupled with clam shell heaters, and specimen size is relatively small, making it a viable post irradiation test method. The culmination of this effort was a draft of an ASTM test standard that will be submitted for approval to the ASTM C28 ceramic committee. Once the standard has been vetted by the ceramics test community, an industry wide standard methodology to test joined tubular ceramic components will be available for the entire nuclear materials community.

  5. ASTM STANDARD GUIDE FOR EVALUATING DISPOSAL OPTIONS FOR REUSE OF CONCRETE FROM NUCLEAR FACILITY DECOMMISSIONING

    International Nuclear Information System (INIS)

    Phillips, Ann Marie; Meservey, Richard H.

    2003-01-01

    Within the nuclear industry, many contaminated facilities that require decommissioning contain huge volumes of concrete. This concrete is generally disposed of as low-level waste at a high cost. Much of the concrete is lightly contaminated and could be reused as roadbed, fill material, or aggregate for new concrete, thus saving millions of dollars. However, because of the possibility of volumetric contamination and the lack of a method to evaluate the risks and costs of reusing concrete, reuse is rarely considered. To address this problem, Argonne National Laboratory-East (ANL-E) and the Idaho National Engineering and Environmental Laboratory teamed to write a ''concrete protocol'' to help evaluate the ramifications of reusing concrete within the U.S. Department of Energy (DOE). This document, titled the Protocol for Development of Authorized Release Limits for Concrete at U.S. Department of Energy Site (1) is based on ANL-E's previously developed scrap metal recycle protocols; on the 10-step method outlined in DOE's draft handbook, Controlling Release for Reuse or Recycle of Property Containing Residual Radioactive Material (2); and on DOE Order 4500.5, Radiation Protection of the Public and the Environment (3). The DOE concrete protocol was the basis for the ASTM Standard Guide for Evaluating Disposal Options for Concrete from Nuclear Facility Decommissioning, which was written to make the information available to a wider audience outside DOE. The resulting ASTM Standard Guide is a more concise version that can be used by the nuclear industry worldwide to evaluate the risks and costs of reusing concrete from nuclear facility decommissioning. The bulk of the ASTM Standard Guide focuses on evaluating the dose and cost for each disposal option. The user calculates these from the detailed formulas and tabulated data provided, then compares the dose and cost for each disposal option to select the best option that meets regulatory requirements. With this information

  6. Impact of ASTM Standard E722 update on radiation damage metrics

    Energy Technology Data Exchange (ETDEWEB)

    DePriest, Kendall Russell [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-06-01

    The impact of recent changes to the ASTM Standard E722 is investigated. The methodological changes in the production of the displacement kerma factors for silicon has significant impact for some energy regions of the 1-MeV(Si) equivalent fluence response function. When evaluating the integral over all neutrons energies in various spectra important to the SNL electronics testing community, the change in the response results in an increase in the total 1-MeV(Si) equivalent fluence of 2 7%. Response functions have been produced and are available for users of both the NuGET and MCNP codes.

  7. Relation between the national handbook of recommended methods for water data acquisition and ASTM standards

    Science.gov (United States)

    Glysson, G. Douglas; Skinner, John V.

    1991-01-01

    In the late 1950's, intense demands for water and growing concerns about declines in the quality of water generated the need for more water-resources data. About thirty Federal agencies, hundreds of State, county and local agencies, and many private organizations had been collecting water data. However, because of differences in procedures and equipment, many of the data bases were incompatible. In 1964, as a step toward establishing more uniformity, the Bureau of the Budget (now the Office of Management and Budget, OMB) issued 'Circular A-67' which presented guidelines for collecting water data and also served as a catalyst for creating the Office of Water Data Coordination (OWDC) within the U.S. Geological Survey. This paper discusses past, present, and future aspects of the relation between methods in the National Handbook and standards published by ASTM (American Society for Testing and Materials) Committee D-19 on Water's Subcommittee D-19.07 on Sediment, Geomorphology, and Open Channel Flow. The discussion also covers historical aspects of standards - development work jointly conducted by OWDC and ASTM.

  8. Modification of ASTM Standard E1681 on Environmental Cracking to Include Bolt-Load Specimen Testing

    National Research Council Canada - National Science Library

    Underwood, Jean D. M

    1997-01-01

    Benet Laboratories experience with environmental cracking of cannon components has been combined with the technical expertise of various participants at ASTM technical meetings and symposia to develop...

  9. ASTM and ASME-BPE Standards--Complying with the Needs of the Pharmaceutical Industry.

    Science.gov (United States)

    Huitt, William M

    2011-01-01

    Designing and building a pharmaceutical facility requires the owner, engineer of record, and constructor to be knowledgeable with regard to the industry codes and standards that apply to this effort. Up until 1997 there were no industry standards directed at the needs and requirements of the pharmaceutical industry. Prior to that time it was a patchwork effort at resourcing and adopting nonpharmaceutical-related codes and standards and then modifying them in order to meet the more stringent requirements of the Food and Drug Administration (FDA). In 1997 the American Society of Mechanical Engineers (ASME) published the first Bioprocessing Equipment (BPE) Standard. Through harmonization efforts this relatively new standard has brought together, scrutinized, and refined industry accepted methodologies together with FDA compliance requirements, and has established an American National Standard that provides a comprehensive set of standards that are integral to the pharmaceutical industry. This article describes various American National Standards, including those developed and published by the American Society for Testing and Materials (ASTM), and how they apply to the pharmaceutical industry. It goes on to discuss the harmonization effort that takes place between the various standards developers in an attempt to prevent conflicts and omissions between the many standards. Also included are examples of tables and figures taken from the ASME-BPE Standard. These examples provide the reader with insight to the relevant content of the ASME-BPE Standard. Designing and building a pharmaceutical facility requires the owner, engineer of record, and constructor to be knowledgeable with regard to the industry codes and standards that apply to this effort. Up until 1997 there were no industry standards directed at the needs and requirements of the pharmaceutical industry. Prior to that time it was a patchwork effort at resourcing and adopting nonpharmaceutical-related codes and

  10. Silicon Damage Response Function Derivation and Verification: Assessment of Impact on ASTM Standard E722

    Energy Technology Data Exchange (ETDEWEB)

    Depriest, Kendall [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-06-01

    Unsuccessful attempts by members of the radiation effects community to independently derive the Norgett-Robinson-Torrens (NRT) damage energy factors for silicon in ASTM standard E722-14 led to an investigation of the software coding and data that produced those damage energy factors. The ad hoc collaboration to discover the reason for lack of agreement revealed a coding error and resulted in a report documenting the methodology to produce the response function for the standard. The recommended changes in the NRT damage energy factors for silicon are shown to have significant impact for a narrow energy region of the 1-MeV(Si) equivalent fluence response function. However, when evaluating integral metrics over all neutrons energies in various spectra important to the SNL electronics testing community, the change in the response results in a small decrease in the total 1- MeV(Si) equivalent fluence of ~0.6% compared to the E722-14 response. Response functions based on the newly recommended NRT damage energy factors have been produced and are available for users of both the NuGET and MCNP codes.

  11. 78 FR 13243 - Updates to Standards Incorporated by Reference; Reapproved ASTM Standards; Technical Amendment

    Science.gov (United States)

    2013-02-27

    ... Characteristics of Plastic Film 2009)[egr]1. and Sheeting. Standard Specification for F682-82a F682-82a 46 56.01-2... (Reapproved Standard Test Method for Determining Gas 2009)[egr]1. Permeability Characteristics of Plastic Film... Permeability Characteristics of Plastic Film and Sheeting (approved May 1, 2009), incorporation by reference...

  12. ASTM Committee D-7 : Wood : promoting safety and standardization for 100 years

    Science.gov (United States)

    David W. Green; Robert L. Ethington

    2004-01-01

    In October 2004, Committee D-7 on Wood of the American Society for Testing and Materials (ASTM) is celebrating 100 years of contributions to the safe and efficient use of wood as a building material. Born during a period of rapid social, economic, and technological change, the Committee faced controversial issues and the challenge of a changing forest resource. This...

  13. Considerations on the ASTM standards 1789-04 and 1422-05 on the forensic examination of ink.

    Science.gov (United States)

    Neumann, Cedric; Margot, Pierre

    2010-09-01

    The ASTM standards on Writing Ink Identification (ASTM 1789-04) and on Writing Ink Comparison (ASTM 1422-05) are the most up-to-date guidelines that have been published on the forensic analysis of ink. The aim of these documents is to cover most aspects of the forensic analysis of ink evidence, from the analysis of ink samples, the comparison of the analytical profile of these samples (with the aim to differentiate them or not), through to the interpretation of the result of the examination of these samples in a forensic context. Significant evolutions in the technology available to forensic scientists, in the quality assurance requirements brought onto them, and in the understanding of frameworks to interpret forensic evidence have been made in recent years. This article reviews the two standards in the light of these evolutions and proposes some practical improvements in terms of the standardization of the analyses, the comparison of ink samples, and the interpretation of ink examination. Some of these suggestions have already been included in a DHS funded project aimed at creating a digital ink library for the United States Secret Service. © 2010 American Academy of Forensic Sciences.

  14. Status on the selection and development of an embrittlement trend curve to use in ASTM standard guide E900

    International Nuclear Information System (INIS)

    Kirk, M.; Brian Hall, J.; Server, W.; Lucon, E.; Erickson, M.; Stoller, R.

    2015-01-01

    ASTM E900-07, Standard Guide for Predicting Radiation-Induced Transition Temperature Shift in Reactor Vessel Materials, includes an embrittlement trend curve. The trend curve can be used to predict the effect of neutron irradiation on the embrittlement of ferritic pressure vessel steels, as quantified by the shift in the Charpy V-Notch transition curve at 41 Joules of absorbed energy (ΔT 41J ). The current E900 trend curve was first adopted in the 2002 revision. In 2011 ASTM Subcommittee E10.02 undertook an extensive effort to evaluate the adequacy of the E900 trend curve for continued use. This paper summarizes the current status of this effort, which has produced a trend curve calibrated using a database of over 1800 ΔT 41J values from the light water reactor surveillance programs in thirteen countries. (authors)

  15. Validation of standard ASTM F2732 and comparison with ISO 11079 with respect to comfort temperature ratings for cold protective clothing.

    Science.gov (United States)

    Gao, Chuansi; Lin, Li-Yen; Halder, Amitava; Kuklane, Kalev; Holmér, Ingvar

    2015-01-01

    American standard ASTM F2732 estimates the lowest environmental temperature for thermal comfort for cold weather protective clothing. International standard ISO 11079 serves the same purpose but expresses cold stress in terms of required clothing insulation for a given cold climate. The objective of this study was to validate and compare the temperature ratings using human subject tests at two levels of metabolic rates (2 and 4 MET corresponding to 116.4 and 232.8 W/m(2)). Nine young and healthy male subjects participated in the cold exposure at 3.4 and -30.6 °C. The results showed that both standards predict similar temperature ratings for an intrinsic clothing insulation of 1.89 clo and for 2 MET activity. The predicted temperature rating for 2 MET activity is consistent with test subjects' thermophysiological responses, perceived thermal sensation and thermal comfort. For 4 MET activity, however, the whole body responses were on the cold side, particularly the responses of the extremities. ASTM F2732 is also limited due to its omission and simplification of three climatic variables (air velocity, radiant temperature and relative humidity) and exposure time in the cold which are of practical importance. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  16. Analysis and evaluation of the Electronic Health Record standard in China: a comparison with the American national standard ASTM E 1384.

    Science.gov (United States)

    Xu, Wei; Guan, Zhiyu; Cao, Hongxin; Zhang, Haiyan; Lu, Min; Li, Tiejun

    2011-08-01

    To analyze and evaluate the newly issued Electronic Health Record (EHR) Architecture and Data Standard of China (Chinese EHR Standard) and identify areas of improvement for future revisions. We compared the Chinese EHR Standard with the standard of the American Society for Testing and Materials Standard Practice for Content and Structure of Electronic Health Records in the United States (ASTM E 1384 Standard). The comparison comprised two steps: (1) comparing the conformance of the two standards to the international standard: Health Informatics-Requirements for an Electronic Health Record Architecture (ISO/TS 18308), and showing how the architectures of the two standards satisfy or deviate from the ISO requirements and (2) comparing the detailed data structures between the two standards. Of the 124 requirement items in ISO/TS 18308, the Chinese EHR Standard and the ASTM E 1384 Standard conformed to 77 (62.1%) and 111 (89.5%), respectively. The Chinese EHR Standard conformed to 34 of 50 Structure requirements (68.0%), 22 of 24 Process requirements (91.7%), and 21 of 50 Other requirements (42.0%). The ASTM E 1384 Standard conformed to 49 of 50 Structure requirements (98.0%), 23 of 24 Process requirements (95.8%), and 39 of 40 Other requirements (78.0%). Further development of the Chinese EHR Standard should focus on supporting privacy and security mechanism, diverse data types, more generic and extensible lower level data structures, and relational attributes for data elements. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  17. Standard test method for compressive strength of grouts for preplaced-aggregate concrete in the laboratory. ASTM standard

    International Nuclear Information System (INIS)

    1998-10-01

    DoD adopted. This test method is under the jurisdiction of ASTM Committee C-9 on Concrete and Concrete Aggregates and is the direct responsibility of Subcommittee C09.41 on Concrete for Radiation Shielding. Current edition approved Feb. 10, 1986 and published October 1998. Originally published as C 942-81. Last previous edition was C 942-86(1991)

  18. Standard test method for static leaching of monolithic waste forms for disposal of radioactive waste. ASTM standard

    International Nuclear Information System (INIS)

    1998-10-01

    This test method is under the jurisdiction of ASTM Committee C-26 on Nuclear Fuel Cycles and is the direct responsibility of Subcommittee C26.07 on Waste Materials. The current edition was approved July 10, 1998, and published in October 1998. It was originally published as C 1220-92. The last previous edition was C 1220-92

  19. Measurement of susceptibility artifacts with histogram-based reference value on magnetic resonance images according to standard ASTM F2119.

    Science.gov (United States)

    Heinrich, Andreas; Teichgräber, Ulf K; Güttler, Felix V

    2015-12-01

    The standard ASTM F2119 describes a test method for measuring the size of a susceptibility artifact based on the example of a passive implant. A pixel in an image is considered to be a part of an image artifact if the intensity is changed by at least 30% in the presence of a test object, compared to a reference image in which the test object is absent (reference value). The aim of this paper is to simplify and accelerate the test method using a histogram-based reference value. Four test objects were scanned parallel and perpendicular to the main magnetic field, and the largest susceptibility artifacts were measured using two methods of reference value determination (reference image-based and histogram-based reference value). The results between both methods were compared using the Mann-Whitney U-test. The difference between both reference values was 42.35 ± 23.66. The difference of artifact size was 0.64 ± 0.69 mm. The artifact sizes of both methods did not show significant differences; the p-value of the Mann-Whitney U-test was between 0.710 and 0.521. A standard-conform method for a rapid, objective, and reproducible evaluation of susceptibility artifacts could be implemented. The result of the histogram-based method does not significantly differ from the ASTM-conform method.

  20. Standard specification for cobalt-chromium-nickel-molybdenum-tungsten alloy (UNS R31233) plate, sheet and strip. ASTM standard

    International Nuclear Information System (INIS)

    1998-09-01

    This specification is under the jurisdiction of ASTM Committee B-2 on Nonferrous Metals and Alloys and is the direct responsibility of Subcommittee B02.07 on Refined Nickel and Cobalt, and Alloys Containing Nickel or Cobalt or Both as Principal Constituents. Current edition approved Apr. 10, 1998 and published September 1998. Originally published as B 818-91. Last previous edition was B 818-93

  1. Fractionation and characterization of particles simulating wear of total joint replacement (TJR) following ASTM standards.

    Science.gov (United States)

    Saha, Subrata; Musib, Mrinal

    2011-01-01

    Reactions of bone cells to orthopedic wear debris produced by the articulating motion of total joint replacements (TJRs) are largely responsible for the long-term failure of such replacements. Metal and polyethylene (PE) wear particles isolated from fluids from total joint simulators, as well as particles that are fabricated by other methods, are widely used to study such in vitro cellular response. Prior investigations have revealed that cellular response to wear debris depends on the size, shape, and dose of the particles. Hence, to have a better understanding of the wear-mediated osteolytic process it is important that these particles are well characterized and clinically relevant, both qualitatively, and quantitatively. In this study we have fractionated both ultra-high molecular weight polyethylene (UHMWPE) and Ti particles, into micron (1.0-10.0 μm), submicron (0.2-1.0 μm), and nanoparticle (0.01-0.2 μm) fractions, and characterized them based on the following size-shape descriptors as put forth in ASTM F1877: i) equivalent circle diameter (ECD), ii) aspect ratio (AR), iii) elongation (E), iv) roundness (R), and v) form factor (FF). The mean (± SD) ECDs (in μm) for micron, submicron, and nanoparticles of UHMWPE were 1.652 ± 0.553, 0.270 ± 0.180, and 0.061 ± 0.035, respectively, and for Ti were 1.894 ± 0.667, 0.278 ± 0.180, and 0.055 ± 0.029, respectively. The values for other descriptors were similar (no statistically significant difference). The nanofraction particles were found to be more sphere-like (higher R and FF values, and lower E and AR values) as compared to larger particles. Future experiments will involve use of these well characterized particles for in vitro studies.

  2. Evaluation of ozonated water using ASTM E1174 for standardized testing of handwash formulations for healthcare personnel.

    Science.gov (United States)

    Nakamura, K; Saito, K; Kashiwazaki, J; Aoyagi, T; Arai, K; Hara, Y; Kobari, S; Mori, H; Ohashi, K; Takano, Y; Kaku, M; Kanemitsu, K

    2018-02-13

    Removal of bacteria by handwashing with ozonated water was evaluated using the ASTM E1174 standard test method. Thirty healthy volunteers were assigned randomly to three groups: ozonated water, antimicrobial soap and water, and non-antimicrobial soap and water. A 3 log 10  cfu reduction was achieved by washing hands with ozonated water or antimicrobial soap and water. However, ozonated water was not significantly superior to non-antimicrobial soap and water. Ozonated water may remove bacteria from the hands to at least a similar extent as that by non-antimicrobial soap and water in the absence of visible dirt or body fluid contamination. Copyright © 2018 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  3. Empirical ranking of a wide range of WC-Co grades in terms of their abrasion resistance measured by the ASTM standard B 611-85 test

    CSIR Research Space (South Africa)

    O'Quigley, DGF

    1997-01-01

    Full Text Available This paper reports the results of a comprehensive investigation into the abrasion resistance of WC-Co alloys, as measured by the ASTM Standard B 611-85 test. The alloys ranged from 3 to 50 wt% and from 0.6 to 5 mu-m average grain size. Careful...

  4. ASTM F1717 standard for the preclinical evaluation of posterior spinal fixators: can we improve it?

    Science.gov (United States)

    La Barbera, Luigi; Galbusera, Fabio; Villa, Tomaso; Costa, Francesco; Wilke, Hans-Joachim

    2014-10-01

    Preclinical evaluation of spinal implants is a necessary step to ensure their reliability and safety before implantation. The American Society for Testing and Materials reapproved F1717 standard for the assessment of mechanical properties of posterior spinal fixators, which simulates a vertebrectomy model and recommends mimicking vertebral bodies using polyethylene blocks. This set-up should represent the clinical use, but available data in the literature are few. Anatomical parameters depending on the spinal level were compared to published data or measurements on biplanar stereoradiography on 13 patients. Other mechanical variables, describing implant design were considered, and all parameters were investigated using a numerical parametric finite element model. Stress values were calculated by considering either the combination of the average values for each parameter or their worst-case combination depending on the spinal level. The standard set-up represents quite well the anatomy of an instrumented average thoracolumbar segment. The stress on the pedicular screw is significantly influenced by the lever arm of the applied load, the unsupported screw length, the position of the centre of rotation of the functional spine unit and the pedicular inclination with respect to the sagittal plane. The worst-case combination of parameters demonstrates that devices implanted below T5 could potentially undergo higher stresses than those described in the standard suggestions (maximum increase of 22.2% at L1). We propose to revise F1717 in order to describe the anatomical worst case condition we found at L1 level: this will guarantee higher safety of the implant for a wider population of patients. © IMechE 2014.

  5. ASTM lights the way for tissue engineered medical products standards: jump start for combination medical products that restore biological function of human tissues.

    Science.gov (United States)

    Picciolo, G L; Stocum, D L

    2001-01-01

    Everybody hopes for better health and restoration of impaired bodily function, and now that hope is illuminated by the promise of powerful biological tools that make human cells grow and replace human tissue. ASTM Committee F04 on Medical and Surgical Materials and Devices is taking the lead by defining some of those tools as standards that can be used for the development, production, testing, and regulatory approval of medical products.

  6. ASTM Committee C28: International Standards for Properties and Performance of Advanced Ceramics-Three Decades of High-Quality, Technically-Rigorous Normalization

    Science.gov (United States)

    Jenkins, Michael G.; Salem, Jonathan A.

    2016-01-01

    Physical and mechanical properties and performance of advanced ceramics and glasses are difficult to measure correctly without the proper techniques. For over three decades, ASTM Committee C28 on Advanced Ceramics, has developed high-quality, technically-rigorous, full-consensus standards (e.g., test methods, practices, guides, terminology) to measure properties and performance of monolithic and composite ceramics that may be applied to glasses in some cases. These standards contain testing particulars for many mechanical, physical, thermal, properties and performance of these materials. As a result these standards are used to generate accurate, reliable, repeatable and complete data. Within Committee C28, users, producers, researchers, designers, academicians, etc. have written, continually updated, and validated through round-robin test programs, 50 standards since the Committee's founding in 1986. This paper provides a detailed retrospective of the 30 years of ASTM Committee C28 including a graphical pictogram listing of C28 standards along with examples of the tangible benefits of standards for advanced ceramics to demonstrate their practical applications.

  7. ASTM Committee C28: International Standards for Properties and Performance of Advanced Ceramics, Three Decades of High-quality, Technically-rigorous Normalization

    Science.gov (United States)

    Jenkins, Michael G.; Salem, Jonathan A.

    2016-01-01

    Physical and mechanical properties and performance of advanced ceramics and glasses are difficult to measure correctly without the proper techniques. For over three decades, ASTM Committee C28 on Advanced Ceramics, has developed high quality, rigorous, full-consensus standards (e.g., test methods, practices, guides, terminology) to measure properties and performance of monolithic and composite ceramics that may be applied to glasses in some cases. These standards testing particulars for many mechanical, physical, thermal, properties and performance of these materials. As a result these standards provide accurate, reliable, repeatable and complete data. Within Committee C28 users, producers, researchers, designers, academicians, etc. have written, continually updated, and validated through round-robin test programs, nearly 50 standards since the Committees founding in 1986. This paper provides a retrospective review of the 30 years of ASTM Committee C28 including a graphical pictogram listing of C28 standards along with examples of the tangible benefits of advanced ceramics standards to demonstrate their practical applications.

  8. Use of Bayesian Methods to Analyze and Visualize Content Uniformity Capability Versus United States Pharmacopeia and ASTM Standards.

    Science.gov (United States)

    Hofer, Jeffrey D; Rauk, Adam P

    2017-02-01

    The purpose of this work was to develop a straightforward and robust approach to analyze and summarize the ability of content uniformity data to meet different criteria. A robust Bayesian statistical analysis methodology is presented which provides a concise and easily interpretable visual summary of the content uniformity analysis results. The visualization displays individual batch analysis results and shows whether there is high confidence that different content uniformity criteria could be met a high percentage of the time in the future. The 3 tests assessed are as follows: (a) United States Pharmacopeia Uniformity of Dosage Units , (b) a specific ASTM E2810 Sampling Plan 1 criterion to potentially be used for routine release testing, and (c) another specific ASTM E2810 Sampling Plan 2 criterion to potentially be used for process validation. The approach shown here could readily be used to create similar result summaries for other potential criteria. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  9. International cooperative effort to establish ASTM [American Society for Testing and Materials] standards for the measurement of radiation dose for food processing

    International Nuclear Information System (INIS)

    Farrar, H. IV.

    1987-01-01

    A task group has been formed within the American Society for Testing and Materials (ASTM) specifically to develop standards for measuring radiation dose for food processing. The task group, which has 78 members, including 16 from Europe, consists of a broad cross section of food industry, government, regulatory, manufacturing, and university interests. The group is working on seven standards; three specifically for food irradiation applications, and four for using specific dosimeter types for all radiation applications, including food processing. Together, this set of standards will specify acceptable methods of accomplishing the required irradiation treatment of food and other products, and will be available for adoption by regulatory agencies in food irradiation protocols. 1 tab

  10. Standard practice for application of thermoluminescence-dosimetry (TLD) systems for determining absorbed dose in radiation-hardness testing of electronic devices. ASTM standard

    International Nuclear Information System (INIS)

    1998-05-01

    This practice is under the jurisdiction of ASTM Committee E-10 on Nuclear Technology and Applications and is the direct responsibility of Subcommittee E10.07 on Radiation Dosimetry for Radiation Effects on Materials and Devices. Current edition approved Jun. 10, 1997. Published May 1998. Originally published as E 668-78. Last previous edition E 668-93

  11. Stress corrosion (Astm G30-90 standard) in 08x18H10T stainless steel of nuclear fuel storage pool in WWER reactors

    International Nuclear Information System (INIS)

    Herrera, V.; Zamora R, L.

    1997-01-01

    At the water storage of the irradiated nuclear fuel has been an important factor in its management. The actual pools have its walls covered with inoxidable steel and heat exchangers to dissipate the residual heat from fuel. It is essential to control the water purity to eliminate those conditions which aid to the corrosion process in fuel and at related components. The steel used in this research was obtained from an austenitic inoxidizable steel standardized with titanium 08x18H10T (Type 321) similar to one of the two steel coatings used to cover walls and the pools floor. the test consisted in the specimen deformation through an U ply according to the Astm G30-90 standard. The exposition of the deformed specimen it was realized in simulated conditions to the chemical regime used in pools. (Author)

  12. Disinfectant wipes are appropriate to control microbial bioburden from surfaces: use of a new ASTM standard test protocol to demonstrate efficacy.

    Science.gov (United States)

    Sattar, S A; Bradley, C; Kibbee, R; Wesgate, R; Wilkinson, M A C; Sharpe, T; Maillard, J-Y

    2015-12-01

    The use of disinfectant pre-soaked wipes (DPW) to decontaminate high-touch environmental surfaces (HTES) by wiping is becoming increasingly widespread in the healthcare environment. However, DPW are rarely tested using conditions simulating their field use, and the label claims of environmental surface disinfectants seldom include wiping action. To evaluate the new E2967-15 standard test specific to wipes, particularly their ability to decontaminate surfaces and to transfer acquired contamination to clean surfaces. ASTM Standard E2967-15 was used by three independent laboratories to test the efficacy of five types of commercially available wipe products. All data generated were pulled together, and reproducibility and repeatability of the standard were measured. All the commercial DPW tested achieved a >4log10 (>99.99%) reduction in colony-forming units (CFU) of Staphylococcus aureus and Acinetobacter baumanii with 10s of wiping, but only one DPW containing 0.5% accelerated H2O2 prevented the transfer of bacteria to another surface. This newly introduced standard method represents a significant advance in assessing DPW for microbial decontamination of HTES, and should greatly assist research and development, and in making more relevant and reliable claims on marketed DPW. Copyright © 2015. Published by Elsevier Ltd.

  13. Development of an ASTM standard glass durability test, the Product Consistency Test (PCT), for high level radioactive waste glass

    International Nuclear Information System (INIS)

    Jantzen, C.M.; Bibler, N.E.; Beam, D.C.; Ramsey, W.G.

    1994-01-01

    The nation's first, and the world's largest, facility to immobilize high-level nuclear waste in durable borosilicate glass has started operation at the Savannah River Site (SRS) in Aiken, South Carolina. The product specifications on the glass wasteform produced in the Defense Waste Processing Facility (DWPF) required extensive characterization of the glass product before actual production began and for continued characterization during production. To aid in this characterization, a glass durability (leach) test was needed that was easily reproducible, could be performed remotely on highly radioactive samples, and could yield results rapidly. Several standard leach tests were examined with a variety of test configurations. Using existing tests as a starting point, the DWPF Product Consistency Test (PCT was developed in which crushed glass samples are exposed to 90 ± 2 degree C deionized water for seven days. Based on extensive testing, including a seven-laboratory round robin and confirmatory testing with radioactive samples, the PCT is very reproducible, yields reliable results rapidly, and can be performed in shielded cell facilities with radioactive samples

  14. Evaluating the Sporicidal Activity of Disinfectants against Clostridium difficile and Bacillus amyloliquefaciens Spores by Using the Improved Methods Based on ASTM E2197-11.

    Science.gov (United States)

    Uwamahoro, Marie Christine; Massicotte, Richard; Hurtubise, Yves; Gagné-Bourque, François; Mafu, Akier Assanta; Yahia, L'Hocine

    2018-01-01

    Spore-forming pathogenic bacteria, such as Clostridium difficile , are associated with nosocomial infection, leading to the increased use of sporicidal disinfectants, which impacts socioeconomic costs. However, C. difficile can be prevented using microorganisms such as Bacillus amyloliquefaciens , a prophylactic agent that has been proven to be effective against it in recent tests or it can be controlled by sporicidal disinfectants. These disinfectants against spores should be evaluated according to a known and recommended standard. Unfortunately, some newly manufactured disinfectants like Bioxy products have not yet been tested. ASTM E2197-11 is a standard test that uses stainless steel disks (1 cm in diameter) as carriers, and the performance of the test formulation is calculated by comparing the number of viable test organisms to that on the control carriers. Surface tests are preferable for evaluating disinfectants with sporicidal effects on hard surfaces. This study applies improved methods, based on the ASTM E2197-11 standard, for evaluating and comparing the sporicidal efficacies of several disinfectants against spores of C. difficile and B. amyloliquefaciens , which are used as the test organisms. With the improved method, all spores were recovered through vortexing and membrane filtration. The results show that chlorine-based products are effective in 5 min and Bioxy products at 5% w/v are effective in 10 min. Although Bioxy products may take longer to prove their effectiveness, their non-harmful effects to hospital surfaces and people have been well established in the literature.

  15. 78 FR 57818 - Commission Participation and Commission Employee Involvement in Voluntary Standards Activities

    Science.gov (United States)

    2013-09-20

    ... docket number for this rulemaking. All comments received may be posted without change, including any... found in in such locations as homes, schools, and recreational areas. Voluntary standards activity is an... handled primarily by three standards development/coordinating organizations: ASTM International...

  16. DEVELOPING STANDARDS FOR ASSESSING ENVIRONMENTAL CHEMICAL, PHYSICAL, AND BIOLOGICAL STRESSORS THROUGH ASTM COMMITTEE E47: A PAST FOUNDATION OF PROVEN STANDARDS, A FUTURE OF GREAT POTENTIAL AND OPPORTUNITY

    Science.gov (United States)

    Development of standards associated with assessing the bioavailability of contaminants in sediment will be used as a case study for how standards have been developed through Committee E47. In 1987, Committee E47 established Subcommittee E47.03 on Sediment Assessment and Toxicity....

  17. ASTM Validates Air Pollution Test Methods

    Science.gov (United States)

    Chemical and Engineering News, 1973

    1973-01-01

    The American Society for Testing and Materials (ASTM) has validated six basic methods for measuring pollutants in ambient air as the first part of its Project Threshold. Aim of the project is to establish nationwide consistency in measuring pollutants; determining precision, accuracy and reproducibility of 35 standard measuring methods. (BL)

  18. Stress corrosion (Astm G30-90 standard) in 08x18H10T stainless steel of nuclear fuel storage pool in WWER reactors; Corrosion bajo esfuerzo (Norma ASTM G30-90) en acero inoxidable 08x18H10T de piscinas de almacenamiento de combustible nuclear en reactores V.V.E.R

    Energy Technology Data Exchange (ETDEWEB)

    Herrera, V.; Zamora R, L. [Centro de Estudios Aplicados al Desarrollo Nuclear (Cuba)

    1997-07-01

    At the water storage of the irradiated nuclear fuel has been an important factor in its management. The actual pools have its walls covered with inoxidable steel and heat exchangers to dissipate the residual heat from fuel. It is essential to control the water purity to eliminate those conditions which aid to the corrosion process in fuel and at related components. The steel used in this research was obtained from an austenitic inoxidizable steel standardized with titanium 08x18H10T (Type 321) similar to one of the two steel coatings used to cover walls and the pools floor. the test consisted in the specimen deformation through an U ply according to the Astm G30-90 standard. The exposition of the deformed specimen it was realized in simulated conditions to the chemical regime used in pools. (Author)

  19. Current and future neutron radiography standards

    International Nuclear Information System (INIS)

    Brenizer, J.S.

    1999-01-01

    Only two organizations are actively producing standards which are used in neutron radiology (NR): the American Society of Testing and Materials (ASTM) and the International Organization for Standardization (ISO). Six ASTM standards exist that address the neutron radiography method. Two of the ASTM standards have been extensively used world-wide. ISO has a working group which is developing three standards that also address the neutron radiography method. Two of these are currently making their way through the ISO approval system. No ASTM or ISO standards exist for the neutron radioscopic method. Future ASTM standards will address the neutron radioscopic method and neutron radiologic system characterization. It is expected that similar efforts will be undertaken in ISO. Given the relatively small community providing neutron radiologic services, international cooperation and the need for ISO standards will most likely continue to grow.(author)

  20. An evaluation of efforts by nuclear power plants to use ASTM D3803-89

    International Nuclear Information System (INIS)

    Freeman, W.P.

    1995-01-01

    The number of nuclear power plants are now using ASTM D3803-89, open-quotes Standard Test Method for Nuclear-Grade Activated Carbonclose quotes for routine surveillance testing of adsorbents. In order to judge the impact of this change, we have gathered radioiodine removal test results from our data base on a system-by-system basis (i.e. control room, technical support center, and spent fuel pool) and compared test results obtained for the same kind of systems using the new and older test methods. Included in this comparison are systems with and without humidity control. Results are discussed from the standpoint of what to expect if a change to testing using ASTM D3803-89 is contemplated, especially regarding test results in light existing acceptance criteria. Additionally, the results are discussed from the standpoint of the sensitivity of the ASTM test method to detect when the performance of the carbon in air cleaning systems has been compromised (compared to the older methods). Finally, we offer some suggestions for how other plants might upgrade their carbon testing to incorporate testing to ASTM D3803-89

  1. An evaluation of efforts by nuclear power plants to use ASTM D3803-89

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, W.P.

    1995-02-01

    The number of nuclear power plants are now using ASTM D3803-89, {open_quotes}Standard Test Method for Nuclear-Grade Activated Carbon{close_quotes} for routine surveillance testing of adsorbents. In order to judge the impact of this change, we have gathered radioiodine removal test results from our data base on a system-by-system basis (i.e. control room, technical support center, and spent fuel pool) and compared test results obtained for the same kind of systems using the new and older test methods. Included in this comparison are systems with and without humidity control. Results are discussed from the standpoint of what to expect if a change to testing using ASTM D3803-89 is contemplated, especially regarding test results in light existing acceptance criteria. Additionally, the results are discussed from the standpoint of the sensitivity of the ASTM test method to detect when the performance of the carbon in air cleaning systems has been compromised (compared to the older methods). Finally, we offer some suggestions for how other plants might upgrade their carbon testing to incorporate testing to ASTM D3803-89.

  2. Comparison of ASTM D613 and ASTM D6890

    Science.gov (United States)

    2016-04-01

    cetane values outside of the routine range of traditional CN testing by ASTM D613, this is an important advantage in fuel blending and disposition...Number testing. Particular emphasis was placed on evaluating fuels, and blends thereof, having cetane values outside of the normal range of the...interest covers both petroleum-based and synthetic-based, as well as blends thereof in order to improve the confidence in using DCN as a replacement

  3. Transferability of ASTM/NIST alanine-polyethylene recipe at ISS. American Society for Testing and Materials/National Institute for Standards and Technology. Istituto Superiore de Sanita

    Science.gov (United States)

    De Angelis C; Fattibene; Onori; Petetti; Bartolotta; Sansone Santamaria A

    2000-05-01

    Alanine-polyethylene solid state dosimeters were prepared at Istituto Superiore di Sanita (ISS) following the recipe proposed by National Institute of Standards and Technology (NIST) with the goal of testing its transferability. Dosimeters were prepared using 95% alanine and 5% polyethylene, by weight. They are rugged and of increased sensitivity, repeatability and reproducibility as respect to the ISS alanine-paraffin pellets. Reproducibility of about 1% was obtained at 10 Gy and at 3 Gy if one single pellet or a stack of five dosimeters were used, respectively.

  4. Activities of Radiation Standard Section

    International Nuclear Information System (INIS)

    Kannan, A.; Rao, P.S.; Sachadev, R.N.; Shaha, V.V.; Sharma, D.; Srivastava, P.K.

    1992-01-01

    A brief account of the various facilities and services provided by the Radiation Standards Section (RSS) of the Bhabha Atomic Research Centre, Bombay is given. RSS maintains the primary and secondary standards of various parameters of radiation measurements. It ensures accurate radiological measurements as per international requirements, through periodic international intercomparisons of national standards. It also provides calibration services to various users of radiation sources and instruments. The activities of RSS are described under the headings: (1) Radiological Metrology Standards, (2) Radionuclide Standards, Neutron Metrology, (4) Instruments Calibration, (5) Non-ionizing Radiations, and (6) Instrumentation. (author). figs., tabs

  5. Biodiesel Fuel Quality and the ASTM Standard

    Science.gov (United States)

    Biodiesel is usually produced from vegetable oils, animal fats and used cooking oils with alternative feedstocks such as algae receiving increasing interest. The transesterification reaction which produces biodiesel also produces glycerol and proceeds stepwise via mono- and diacylglycerol intermedia...

  6. Spectrophotometric determination of the ASTM color of diesel oil

    Energy Technology Data Exchange (ETDEWEB)

    Douglas Willian Emanuel Alves Santana; Marcelle Prates Sepulveda; Paulo Jorge Sanches Barbeira

    2007-03-15

    One of the parameters analyzed to determine the quality of diesel oil is its ASTM color. Changes in color may be indicative of problems in the production process, contamination, degradation or the oxidation of diesel. The methodology recommended for determining the color of automotive diesel oil samples is the colorimetry according to standard ASTM D1500, in which a sample is introduced into a glass cell and the color of the sample is compared with an optical filter color scale. Although it is very simple, the manual method requires good visual acuity from the operator. This procedure becomes somewhat subjective in some cases since different operators can make distinct evaluations of the same sample. In this way, this work proposes the development of a spectrophotometric analysis methodology to eliminate the subjectiveness in the determination of ASTM color of diesel oil samples by using operator-independent parameters and making quality assay more accurate and precise. Short communication. 7 refs., 2 figs., 2 tabs.

  7. Active Faraday optical frequency standard.

    Science.gov (United States)

    Zhuang, Wei; Chen, Jingbiao

    2014-11-01

    We propose the mechanism of an active Faraday optical clock, and experimentally demonstrate an active Faraday optical frequency standard based on narrow bandwidth Faraday atomic filter by the method of velocity-selective optical pumping of cesium vapor. The center frequency of the active Faraday optical frequency standard is determined by the cesium 6 (2)S(1/2) F=4 to 6 (2)P(3/2) F'=4 and 5 crossover transition line. The optical heterodyne beat between two similar independent setups shows that the frequency linewidth reaches 281(23) Hz, which is 1.9×10(4) times smaller than the natural linewidth of the cesium 852-nm transition line. The maximum emitted light power reaches 75 μW. The active Faraday optical frequency standard reported here has advantages of narrow linewidth and reduced cavity pulling, which can readily be extended to other atomic transition lines of alkali and alkaline-earth metal atoms trapped in optical lattices at magic wavelengths, making it useful for new generation of optical atomic clocks.

  8. [Comparison of susceptibility artifacts generated by microchips with different geometry at 1.5 Tesla magnet resonance imaging. A phantom pilot study referring to the ASTM standard test method F2119-07].

    Science.gov (United States)

    Dengg, S; Kneissl, S

    2013-01-01

    Ferromagnetic material in microchips, used for animal identification, causes local signal increase, signal void or distortion (susceptibility artifact) on MR images. To measure the impact of microchip geometry on the artifact's size, an MRI phantom study was performed. Microchips of the labels Datamars®, Euro-I.D.® and Planet-ID® (n  =  15) were placed consecutively in a phantom and examined with respect to the ASTM Standard Test Method F2119-07 using spin echo (TR 500 ms, TE 20 ms), gradient echo (TR 300 ms, TE 15 ms, flip angel 30°) and otherwise constant imaging parameters (slice thickness 3 mm, field of view 250 x 250 mm, acquisition matrix 256 x 256 pixel, bandwidth 32 kHz) at 1.5 Tesla. Image acquisition was undertaken with a microchip positioned in the x- and z-direction and in each case with a phase-encoding direction in the y- and z-direction. The artifact size was determined with a) a measurement according to the test method F2119-07 using a homogeneous point operation, b) signal intensity measurement according to Matsuura et al. and c) pixel counts in the artifact according to Port and Pomper. There was a significant difference in artifact size between the three microchips tested (Wilcoxon p = 0.032). A two- to three-fold increase in microchip volume generated an up to 76% larger artifact, depending on the sequence type, phase-encoding direction and chip position to B0. The smaller the microchip geometry, the less is the susceptibility artifact. Spin echoes (SE) generated smaller artifacts than gradient echoes (GE). In relation to the spatial measurement of the artifact, the switch in phase-encoding direction had less influence on the artifact size in GE- than in SE-sequences. However, the artifact shape and direction of SE-sequences can be changed by altering the phase. The artifact size, caused by the microchip, plays a major clinical role in the evaluation of MRI from the head, shoulder and neck regions.

  9. National standards for the nuclear industry

    International Nuclear Information System (INIS)

    Laing, W.R.; Corbin, L.T.

    1981-01-01

    Standards needs for the nuclear industry are being met by a number of voluntary organizations, such as ANS, ASTM, AWS, ASME, and IEEE. The American National Standards Institute (ANSI) coordinates these activities and approves completed standards as American National Standards. ASTM has two all-nuclear committees, E-10 and C-26. A C-26 subcommittee, Test Methods, has been active in writing analytical chemistry standards for twelve years. Thirteen have been approved as ANSI standards and others are ready for ballot. Work is continuing in all areas of the nuclear fuel cycle

  10. PROPOSED ASTM METHOD FOR THE DETERMINATION OF ASBESTOS IN AIR BY TEM AND INFORMATION ON INTERFERING FIBERS

    Science.gov (United States)

    The draft of the ASTM Test Method for air entitled: "Airborne Asbestos Concentration in Ambient and Indoor Atmospheres as Determined by Transmission Electron Microscopy Direct Transfer (TEM)" (ASTM Z7077Z) is an adaptation of the International Standard, ISO 10312. It is currently...

  11. Argentine nuclear energy standardization activities

    International Nuclear Information System (INIS)

    Boero, Norma; Corcuera, Roberto; Palacios, Tulio A.; Hey, Alfredo M.; Berte, G.; Trama, L.

    2004-01-01

    The International Organization for Standardization (ISO) has more than 200 Technical Committees that develop technical standards. During April 2004 took place in Buenos Aires the 14th Plenary of the ISO/TC 85 Nuclear Energy Committee. During this Plenary issues as Nuclear Terminology, Radiation Protection, Nuclear Fuels, Nuclear Reactors and Irradiation Dosimetry was dealt with. 105 International delegates and 45 National delegates (belonging to CNEA, ARN, NASA, INVAP, CONUAR, IONICS and other organizations) attended the meetings. During this meeting ISO/TC 85 changed its scope; the new scope of the Committee is 'Standardization in the fields of peaceful applications of nuclear energy and of the protection of individuals against all sources of ionizing radiations'. This work summarizes the most important advances and resolutions about the development of standards taken during this meeting as well as the main conclusions. (author) [es

  12. Activity and gamma-ray emission standards

    International Nuclear Information System (INIS)

    Debertin, K.

    1983-01-01

    The standards made available by PTB are standards defined with regard to their activity A. If standard and measuring sample do not contain the same nuclide, the comparison with the standard is made via the emission rate R of the photons of a given energy. For this comparison, the value recommended by PTB for PTB standards should be used, as this value in many cases has been derived by emission rate measurements on specimens whose activity has been directly correlated with the activity of the standards released. (orig./DG) [de

  13. Status of Standardization Projects

    Science.gov (United States)

    1993-12-31

    A5 B 942 943 943 ASM SA 69 D, 8115 056; ASTM D 5118 FABRICATION OF FIBERBOARD SM AS B 941 943 943 A SM SA 69 Di- N 8115 0562 ASTM D 5168 FAB AND...DR&E(AR)759 STANDARDIZATION PROJECTS REPORT - 1ST QTR FY 1994 PREPARING ACTIVITY LISTING PA AAPAA p BPP .A- G/ASA NC AC 21 RC G CSOL- Qý yqFyýFT7RL AL...941 943 943 A SM SA 69 DH N 8115 0562 ASTM D 5168 FAB AND CLOSURE TRIPLE WALL SM AS B 941 943 943 A SM SA 69 DH N 8125 0379 V’L-B-61000 BOTTLES

  14. Overview (this manuscript is an overview of an ASTM ...

    Science.gov (United States)

    The Symposium on Developing Consensus Standards for Measuring Chemical Emissions from Spray Polyurethane Foam (SPF) Insulation was held on April 30th and May 1, 2015. Sponsored by ASTM Committee D22 on Air Quality, the symposium was held in Anaheim, CA, in conjunction with the standards development meetings of the Committee. ASTM D22.05 is developing tools to answer fundamental questions: what is emitted from SPF, how long do the emissions persist, how does ventilation impact concentrations and potential exposures? How can we model these processes to address the multiplicity of products, applications, and environmental conditions that may impact exposure to emissions over the life cycle of the material? These are complex and interrelated questions that have challenged the indoor environments research community for many years. Objectives of Symposium: Standardized methods are needed to assess the potential impacts of SPF insulation products on indoor air quality, establish re-entry times for trade workers or re-occupancy times for building occupants after product installation and to evaluate post-occupancy ventilation. The objective of the symposium was to provide a forum for the exchange of ideas from SPF manufacturers, regulatory agencies, indoor air quality professionals, testing labs, air quality consultants, instrument vendors and other stakeholders. Following the presentations on the current status of measuring emissions from SPF insulation, participants di

  15. Interlaboratory Study (ILS) for F 548-01, The Standard Test Method for Intensity of Scratches on Aerospace Transparent Plastics

    National Research Council Canada - National Science Library

    Pinkus, Alan

    2003-01-01

    ...) as outlined in ASTM E 691. This report, which conforms to the ILS reporting format required by ASTM, describes the study that was conducted for ASTM test standard F 548-01, Intensity of Scratches on Aerospace Transparent Plastics...

  16. Control Systems Cyber Security Standards Support Activities

    Energy Technology Data Exchange (ETDEWEB)

    Robert Evans

    2009-01-01

    The Department of Homeland Security’s Control Systems Security Program (CSSP) is working with industry to secure critical infrastructure sectors from cyber intrusions that could compromise control systems. This document describes CSSP’s current activities with industry organizations in developing cyber security standards for control systems. In addition, it summarizes the standards work being conducted by organizations within the sector and provides a brief listing of sector meetings and conferences that might be of interest for each sector. Control systems cyber security standards are part of a rapidly changing environment. The participation of CSSP in the development effort for these standards has provided consistency in the technical content of the standards while ensuring that information developed by CSSP is included.

  17. Applying consensus standards to cask development

    International Nuclear Information System (INIS)

    Leatham, J.; Abbott, D.G.; Warrant, M.M.

    1987-01-01

    The Department of Energy's (DOE's) Office of Civilian Radioactive Waste Management is procuring cask systems for transporting commercial spent nuclear fuel and is encouraging development of innovative cask designs and materials to improve system efficiency. New designs and innovative materials require that consensus standards be established so that cask designers and regulators have criteria for determining acceptability. Recent DOE experience in certifying three spent fuel shipping casks, NUPAC-125B, TN-BRP, and TN-REG, is discussed. Certification of the NUPAC-125B was expedited because it was made of conventional American Society for Testing and Materials (ASTM) materials and complied with the American Society of Mechanical Engineers (ASME) Code and Nuclear Regulatory Commission Regulatory Guides. The TN-BRP and TN-REG cask designs are still being reviewed because baskets included in the casks are made of borated stainless steel, which has no ASTM Specification or ASME Code approval. The process of developing and approving consensus standards is discussed, including the role of ANSI and ANSI N14. Specific procedures for ASTM and ASME are described. A draft specification or standard must be prepared and then approved by the appropriate body. For new material applications to the ASME Code, an existing ASTM Specification is needed. These processes may require several years. The status of activities currently in progress to develop consensus standards for spent fuel casks is discussed, including (1) ASME NUPAC, and (2) ASTM Specifications for ductile cast iron and borated stainless steel

  18. Standardized accounting ashore for afloat activities

    OpenAIRE

    Burr, Michael J.

    1996-01-01

    With limited resources and reduced funding for Naval forces, there is a need to standardize accounting ashore for all afloat activities. The purpose of this thesis was to review the framework for standardization of inventory reporting afloat under one stores (inventory) accounting system, referred to as the Material Financial Control System-Retail (MFCS-Retail). Additional analysis was conducted on general funds obligational reporting for afloat Operating Targets (OPTARS) and the conversion t...

  19. Comparing the Methodologies in ASTM G198: Is There an Easy Way Out?

    Science.gov (United States)

    Samuel L. Zelinka

    2013-01-01

    ASTM(1) G198, Standard test method for determining the relative corrosion performance of driven fasteners in contact with treated wood, was accepted by consensus and published in 2011. The method has two different exposure conditions for determining fastener corrosion performance in treated wood. The first method places the wood and embedded...

  20. Comparing the Methodologies in ASTM G198 Using Combined Hygrothermal-Corrosion Modeling

    Science.gov (United States)

    Samuel L. Zelinka

    2013-01-01

    ASTM G198, “Standard test method for determining the relative corrosion performance of driven fasteners in contact with treated wood,” was accepted by consensus and published in 2011. The method has two different exposure conditions for determining fastener corrosion performance in treated wood. The first method places the wood and embedded fasteners in a...

  1. China and IEC international standardization activities

    Institute of Scientific and Technical Information of China (English)

    Su Zhongmin; Guo Chenguang

    2006-01-01

    @@ International Electrotechnical Commission (IEC), one of the currently worlswide largest and most authoritative international standardization organizations,is specialized in developing and promulgating international standards for the electric and electronic fields, which are widespread adopted through out the world and play an important role in the international trade of electric and electronic products. Moreover, according to the 2005 statistics by the World Bank, the population of countries participating in the IEC activities accounts for 92% of the world total and their trade volume accounts for 95% of the global total.

  2. Stress corrosion cracking (Standard Astm G 30-90) in stainless steel 08X18H10T of swimming-pool that contain nuclear fuel in reactors V.V.E.R.-440

    International Nuclear Information System (INIS)

    Zamora R, L.; Herrera, V.

    1998-01-01

    The standard recommended practice for making and using 'U' bend stress corrosion test specimens; Designation G30-90 has been used as a laboratory tool to study the susceptibility of austenitic stainless steels and the other materials of test of intergranular stress corrosion cracking (IGSCC). The experiment has been development in a similar conditions of the chemical regime, the swimming-pool that containing nuclear fuel in borated water reactors VVER-440 in general this cladding by two films, one of carbon steel (04T26) and other with austenitic stainless steel 08X18HT (similar type 321) stabilized with titanium, the thickness of filler metals was to 4 to 8 mm. The specimens was prepare one plate with this characteristics, the welding was put in the part central with the following measurements of 160x15x5 mm. The specimens strips bent approximately 180 degrees around radius of curvature of R=14.5 mm and ε 1 = 17.2% and maintained in this plastically deformed condition during the test. And then preparing metallographically and exposure in environment of 12 and 40 gr./l of H 3 BO 3 70 Centigrade with or noting contaminants of NaCl. The results showed the initial cracks. (Author)

  3. An Evaluation of a Proposed Revision of the ASTM D 1990 Grouping Procedure

    Science.gov (United States)

    Steve P Verrill; James W. Evans; David E. Kretschmann; Cherilyn A. Hatfield

    2013-01-01

    Lum, Taylor, and Zidek have proposed a revised procedure for wood species grouping in ASTM standard D 1990. We applaud the authors’ recognition of the importance of considering a strength distribution’s variability as well as its fifth percentile. However, we have concerns about their proposed method of incorporating this information into a standard. We detail these...

  4. Standards in capstone design courses and the engineering curriculum.

    Science.gov (United States)

    Goldberg, Jay

    2012-01-01

    In 1990, I was the group leader of Research and Development for Surgitek, a urological device manufacturer in Racine, Wisconsin, which was the market leader in ureteral stents. I recognized the need for an industry standard for ureteral stents, felt that taking a leadership role in the development of a new standard would be a good professional development activity, and volunteered to serve as the chair of the American Society for Testing and Materials (ASTM, now known as ASTM International) Task Group on Ureteral Stents. After several years, the standard was approved, and I continue to serve as the chair of the ASTM Subcommittee on Urological Materials and Devices. This experience helped me understand the value of industry standards, expanded my professional network and visibility within the medical device industry, and helped develop my leadership skills.

  5. Laboratory testing of hemolytic properties of materials that come in contact with blood: Comparative application testing method’s two variants according to the standard ASTM F756 in accordance with ISO 10993-4

    Directory of Open Access Journals (Sweden)

    Pavlović Katarina B.

    2010-01-01

    Full Text Available The presence of hemolytic material in contact with blood may produce increased levels of blood cell lysis and increased levels of plasma hemoglobin. This may induce toxic effects or other effects which may stress the kidneys or other organs. In this paper two variants of in vitro method and obtained results’ comparison were presented for testing of hemolytic properties of six raw materials (Polipropylene Moplen EP 540 P, Policarbonate colorless 164 R-112, Policarbonate brown 164 R-51918, Polietylene NG 3026 K, Polietylene NG - Purell GB 7250, Polietylene VG - Hiplex 5502 for medical device manufacturing and one raw material (Polietylen NG granulate used for infusion solutions’s plastic bottles manufacturing. One of method’s variants relies on raw material direct contact with swine blood and the other on extract of the material contact with swine blood. Both method’s variants imply reading of the absorbance of the supernatant after tubes were incubated and centrifuged. According to values obtained and using the standard curve free hemoglobin concentration is determined and based on this percentage hemolysis of raw material. Positive and negative controls were used in both variants where water for injection (WFI was used as positive control in which partial or complete hemolysis of erythrocytes occurs due to osmotic shock and phosphate buffer saline was used as negative control with no hemolytic property. In this paper comparison of results obtained by both method’s variants for testing of seven raw materials was presented, while these conclusions can not be used neither for all materials, nor for all applications without preliminary testing using both variants and then choosing more sensitive and more reliable one. It was shown and stated in the paper as well that incubation time being 3, 15 or 24 h, had no impact on the variant’s with direct contact sensitivity. This comparative approach was used for drawing conclusions in terms of

  6. Biodiesel Fuel Quality and the ASTM Biodiesel Standard

    Science.gov (United States)

    Biodiesel is usually produced from vegetable oils, animal fats and used cooking oils with alternative feedstocks such as algae receiving increasing interest. The transesterification reaction which produces biodiesel also produces glycerol and proceeds stepwise via mono- and diacylglycerol intermedi...

  7. Results of ASTM round robin testing for mode 1 interlaminar fracture toughness of composite materials

    Science.gov (United States)

    Obrien, T. Kevin; Martin, Roderick H.

    1992-01-01

    The results are summarized of several interlaboratory 'round robin' test programs for measuring the mode 1 interlaminar fracture toughness of advanced fiber reinforced composite materials. Double Cantilever Beam (DCB) tests were conducted by participants in ASTM committee D30 on High Modulus Fibers and their Composites and by representatives of the European Group on Fracture (EGF) and the Japanese Industrial Standards Group (JIS). DCB tests were performed on three AS4 carbon fiber reinforced composite materials: AS4/3501-6 with a brittle epoxy matrix; AS4/BP907 with a tough epoxy matrix; and AS4/PEEK with a tough thermoplastic matrix. Difficulties encountered in manufacturing panels, as well as conducting the tests are discussed. Critical issues that developed during the course of the testing are highlighted. Results of the round robin testing used to determine the precision of the ASTM DCB test standard are summarized.

  8. Standardizing Activation Analysis: New Software for Photon Activation Analysis

    Science.gov (United States)

    Sun, Z. J.; Wells, D.; Segebade, C.; Green, J.

    2011-06-01

    Photon Activation Analysis (PAA) of environmental, archaeological and industrial samples requires extensive data analysis that is susceptible to error. For the purpose of saving time, manpower and minimizing error, a computer program was designed, built and implemented using SQL, Access 2007 and asp.net technology to automate this process. Based on the peak information of the spectrum and assisted by its PAA library, the program automatically identifies elements in the samples and calculates their concentrations and respective uncertainties. The software also could be operated in browser/server mode, which gives the possibility to use it anywhere the internet is accessible. By switching the nuclide library and the related formula behind, the new software can be easily expanded to neutron activation analysis (NAA), charged particle activation analysis (CPAA) or proton-induced X-ray emission (PIXE). Implementation of this would standardize the analysis of nuclear activation data. Results from this software were compared to standard PAA analysis with excellent agreement. With minimum input from the user, the software has proven to be fast, user-friendly and reliable.

  9. Standardizing Activation Analysis: New Software for Photon Activation Analysis

    International Nuclear Information System (INIS)

    Sun, Z. J.; Wells, D.; Green, J.; Segebade, C.

    2011-01-01

    Photon Activation Analysis (PAA) of environmental, archaeological and industrial samples requires extensive data analysis that is susceptible to error. For the purpose of saving time, manpower and minimizing error, a computer program was designed, built and implemented using SQL, Access 2007 and asp.net technology to automate this process. Based on the peak information of the spectrum and assisted by its PAA library, the program automatically identifies elements in the samples and calculates their concentrations and respective uncertainties. The software also could be operated in browser/server mode, which gives the possibility to use it anywhere the internet is accessible. By switching the nuclide library and the related formula behind, the new software can be easily expanded to neutron activation analysis (NAA), charged particle activation analysis (CPAA) or proton-induced X-ray emission (PIXE). Implementation of this would standardize the analysis of nuclear activation data. Results from this software were compared to standard PAA analysis with excellent agreement. With minimum input from the user, the software has proven to be fast, user-friendly and reliable.

  10. Recent activities on nuclear codes and standards

    International Nuclear Information System (INIS)

    Minematsu, Akiyoshi; Ishimoto, Shozaburo; Honjin, Masao

    2000-01-01

    The technical codes and standards relating to the nuclear power stations in Japan are prepared by shapes of laws (ministerial ordinances and bulletins) issued by the government and obliged to comply with by 'the Law concerning the Regulations of Nuclear Material Substances, Nuclear Fuel Substances and Nuclear Reactors' and 'the Electricity Business Act' and of guides defined by the Nuclear Safety Commission, and further some private standards have been issued at a shape of complement of these laws and guides by receiving national recommendation. On the other hand, in the fields of electricity and heat facilities except atomic energy, simplification and feature stipulation of the national technical codes and standards was recently carried out, by which a system usable for the private standards in and out of Japan were prepared through approval of the private Japan Electrotechnical Standards and Codes Committee (JESC). As the nuclear field was now excepted from simultaneous transfer to the private standard and the standard application system, it is expected in future to realize similar transfer if possible and preparation of the private standards is now being advanced. Here were introduced on present state on technical codes and standards relating to the nuclear power generation facilities and recent trends on their private standardization. (G.K.)

  11. Summary: Update to ASTM guide E 1523 to charge control and charge referencing techniques in x-ray photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Baer, D.R.

    2005-01-01

    An updated version of the American Society for Testing and Materials (ASTM) guide E 1523 to the methods to charge control and charge referencing techniques in x-ray photoelectron spectroscopy has been released by ASTM [Annual Book of ASTM Standards Surface Analysis (American Society for Testing and Materials, West Conshohocken, PA, 2004), Vol. 03.06]. The guide is meant to acquaint x-ray photoelectron spectroscopy (XPS) users with the various charge control and charge referencing techniques that are and have been used in the acquisition and interpretation of XPS data from surfaces of insulating specimens. The current guide has been expanded to include new references as well as recommendations for reporting information on charge control and charge referencing. The previous version of the document had been published in 1997 [D. R. Baer and K. D. Bomben, J. Vac. Sci. Technol. A 16, 754 (1998)

  12. Model of ASTM Flammability Test in Microgravity: Iron Rods

    Science.gov (United States)

    Steinberg, Theodore A; Stoltzfus, Joel M.; Fries, Joseph (Technical Monitor)

    2000-01-01

    There is extensive qualitative results from burning metallic materials in a NASA/ASTM flammability test system in normal gravity. However, this data was shown to be inconclusive for applications involving oxygen-enriched atmospheres under microgravity conditions by conducting tests using the 2.2-second Lewis Research Center (LeRC) Drop Tower. Data from neither type of test has been reduced to fundamental kinetic and dynamic systems parameters. This paper reports the initial model analysis for burning iron rods under microgravity conditions using data obtained at the LERC tower and modeling the burning system after ignition. Under the conditions of the test the burning mass regresses up the rod to be detached upon deceleration at the end of the drop. The model describes the burning system as a semi-batch, well-mixed reactor with product accumulation only. This model is consistent with the 2.0-second duration of the test. Transient temperature and pressure measurements are made on the chamber volume. The rod solid-liquid interface melting rate is obtained from film records. The model consists of a set of 17 non-linear, first-order differential equations which are solved using MATLAB. This analysis confirms that a first-order rate, in oxygen concentration, is consistent for the iron-oxygen kinetic reaction. An apparent activation energy of 246.8 kJ/mol is consistent for this model.

  13. Review of ANS-10 standards and activities

    International Nuclear Information System (INIS)

    Poetschat, G.R.

    1981-01-01

    The ANS-10 Standards Subcommittee is sponsored by the Mathematics and Computations Division of the American Nuclear Society. The scope of the ANS-10 Subcommittee includes the development of standards which will promote effective utilization and enhance the reliability of computer programs throughout the nuclear community. The intent of such standards is to improve ease of use, facilitate the exchange, and simplify the conversion of programs. These standards are to be applied during the computer program development process. The development process is the mechanism that creates special properties such as adequate documentation, verification and validation results, ease of use and portability in computer programs which improve reliability and promote effective use. ANS-10 has developed standards for Documentation of Digital Computer Programs, Programming Practices to Facilitate the Interchange of Digital Computer Programs, and Guidelines for Considering User Needs in Computer Program Development. The Documentation and Programming Practices Standards are presently being revised. ANS-10 is presently writing a new standard on verification and validation of computer programs. (orig.) [de

  14. Chronic ankle pain and fibrosis successfully treated with a new noninvasive augmented soft tissue mobilization technique (ASTM): a case report.

    Science.gov (United States)

    Melham, T J; Sevier, T L; Malnofski, M J; Wilson, J K; Helfst, R H

    1998-06-01

    This clinical case report demonstrates the clinical effectiveness of a new form of soft tissue mobilization in the treatment of excessive connective tissue fibrosis (scar tissue) around an athlete's injured ankle. The scar tissue was causing the athlete to have pain with activity, pain on palpation of the ankle, decreased range of motion, and loss of function. Surgery and several months of conventional physical therapy failed to alleviate the athlete's symptoms. As a final resort, augmented soft tissue mobilization (ASTM) was administered. ASTM is an alternative nonsurgical treatment modality that is being researched at Performance Dynamics (Muncip, IN). ASTM is a process that uses ergonomically designed instruments that assist therapists in the rapid localization and effective treatment of areas exhibiting excessive soft tissue fibrosis. This is followed by a stretching and strengthening program. Upon the completion of 6 wk of ASTM therapy, the athlete had no pain and had regained full range of motion and function. This case report is an example of how a noninvasive augmented form of soft tissue mobilization (ASTM) demonstrated impressive clinical results in treating a condition caused by connective tissue fibrosis.

  15. Use of ASTM D5304 in assessing unstable diesel fuel

    Energy Technology Data Exchange (ETDEWEB)

    Turner, L.M.; Martin, C.J. [Defense Fuel Supply Center, Alexandria, VA (United States); Beal, E.J.; Hardy, D.R. [Naval Research Lab., Washington, DC (United States)

    1995-05-01

    The storage stability, or the length of time a fuel can be stored, is of great concern to diesel fuel users. This paper reports on the use of the new ASTM accelerated test for storage stability by oxygen overpressure (D5304) to predict future storage life span of 63,000,000 gallons of a diesel fuel for US Naval vessel use. This paper demonstrates the use of ASTM D5304 at storage times of 16, 40 and 96 hours to accurately determine the length of time that this large quantity of diesel fuel could be stored at ambient temperatures before the maximum allowable amount of particulate contamination was reached.

  16. Characterization of ASTM round-robin tungsten-powder samples

    International Nuclear Information System (INIS)

    Slettevold, C.A.; Biermann, A.H.

    1975-01-01

    The Lawrence Livermore Laboratory Particle Characterization Laboratory Group has participated in an industry-wide round-robin investigation on characterization of tungsten powder. sponsored by the ASTM Subcommittee on Refractory-Metal Powders (B-09.3). The analyses performed at the suggestion of the ASTM subcommittee included measurements of tap density, apparent density, true density, average particle size, and surface area. Determinations of particle-weight and size distributions were also performed and particle inspection conducted by microscopy. This report describes the equipment and procedures used and summarizes the results of these analyses. (9 tables, 17 fig) (U.S.)

  17. Activities of HPS standards committee in environmental remediation

    International Nuclear Information System (INIS)

    Stencel, J.R.

    1994-01-01

    The Health Physics Society (HPS) develops American National Standards in the area of radiation protection using methods approved by the American National Standards Institute (ANSI). Two of its sections, Environmental Health Physics and Contamination Limits, have ongoing standards development which are important to some environmental remediation efforts. This paper describes the role of the HPS standards process and indicates particular standards under development which will be of interest to the reader. In addition, the authors solicit readers to participate in the voluntary standards process by either joining active working groups (WG) or suggesting appropriate and relevant topics which should be placed into the standards process

  18. Light-water reactor pressure vessel surveillance standards

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    The master matrix standard describes a series of standard practices, guides, and methods for the prediction of neutron-induced changes in light-water reactor (LWR) pressure vessel steels throughout a pressure vessel's service life. Some of these are existing American Society for Testing and Materials (ASTM) standards, some are ASTM standards that have been modified, and some are newly proposed ASTM standards. The current (1) scope, (2) areas of application, (3) interrelationships, and (4) status and time table of development, improvement, validation, and calibration for a series of 16 ASTM standards are defined. The standard also includes a discussion of LWR pressure vessel surveillance - justification, requirements, and status of work

  19. Neutron Activation Analysis with k0 Standardization

    International Nuclear Information System (INIS)

    Pomme, S.

    1998-01-01

    SCK-CEN's programme on Neutron Activation Analysis with k 0 -standardisation aims to: (1) develop and implement k 0 -standardisation method for NAA; (2) to exploit the inherent qualities of NAA such as accuracy, traceability, and multi-element capability; (3) to acquire technical spin-off for nuclear measurements services. Main achievements in 1997 are reported

  20. Vacuum decay container/closure integrity testing technology. Part 1. ASTM F2338-09 precision and bias studies.

    Science.gov (United States)

    Wolf, Heinz; Stauffer, Tony; Chen, Shu-Chen Y; Lee, Yoojin; Forster, Ronald; Ludzinski, Miron; Kamat, Madhav; Godorov, Phillip; Guazzo, Dana Morton

    2009-01-01

    ASTM F2338-09 Standard Test Method for Nondestructive Detection of Leaks in Packages by Vacuum Decay Method is applicable for leak-testing rigid and semi-rigid non-lidded trays; trays or cups sealed with porous barrier lidding materials; rigid, nonporous packages; and flexible, nonporous packages. Part 1 of this series describes the precision and bias studies performed in 2008 to expand this method's scope to include rigid, nonporous packages completely or partially filled with liquid. Round robin tests using three VeriPac 325/LV vacuum decay leak testers (Packaging Technologies & Inspection, LLC, Tuckahoe, NY) were performed at three test sites. Test packages were 1-mL glass syringes. Positive controls had laser-drilled holes in the barrel ranging from about 5 to 15 microm in nominal diameter. Two different leak tests methods were performed at each site: a "gas leak test" performed at 250 mbar (absolute) and a "liquid leak test" performed at about 1 mbar (absolute). The gas leak test was used to test empty, air-filled syringes. All defects with holes > or = 5.0 microm and all no-defect controls were correctly identified. The only false negative result was attributed to a single syringe with a ASTM F2338-09 test method and the precision and bias study report are available by contacting ASTM International in West Conshohocken, PA, USA (www.astm.org).

  1. 76 FR 1459 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM International

    Science.gov (United States)

    2011-01-10

    ... Production Act of 1993-ASTM International Notice is hereby given that, on December 6, 2010, pursuant to.... (``the Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with the...

  2. Coordination and standardization of federal sedimentation activities

    Science.gov (United States)

    Glysson, G. Douglas; Gray, John R.

    1997-01-01

    In August 1964, the Bureau of the Budget issued Circular A-67 to set forth guidelines for the coordination of water-data acquisition activities throughout the Federal government. The U.S. Department of the Interior was assigned the task of implementing Circular A-67, which in turn redelegated this responsibility to the U.S. Geological Survey (USGS). Delegation of the lead responsibility for water-data coordination to the USGS occurred because of its historical role as the primary agency for water-data acquisition in the United States. To provide overall leadership for implementing the provisions of Circular A-67, the USGS established the Office of Water Data Coordination in the Water Resources Division (WRD). In addition, regional and district offices of the WRD were delegated responsibility for coordinating water data within their geographic areas of responsibility. On December 10, 1991, the Office of Management and Budget issued OMB Number Memorandum M-92-01, which expands the USGS's coordination role to encompass all water information. This includes data critical to water resources in the following categories: - surface- and ground-water quality and quantity,

  3. Verification of the ASTM G-124 Purge Equation

    Science.gov (United States)

    Robbins, Katherine E.; Davis, Samuel Eddie

    2009-01-01

    ASTM G-124 seeks to evaluate combustion characteristics of metals in high-purity (greater than 99%) oxygen atmospheres. ASTM G-124 provides the following equation to determine the minimum number of purges required to reach this level of purity in a test chamber: n = -4/log10(Pa/Ph), where "n" is the total number of purge cycles required, Ph is the absolute pressure used for the purge on each cycle and Pa is the atmospheric pressure or the vent pressure. The origin of this equation is not known and has been the source of frequent questions as to its accuracy and reliability. This paper shows the derivation of the G-124 purge equation, and experimentally explores the equation to determine if it accurately predicts the number of cycles required.

  4. Isothermal Bainite Processing of ASTM A723 Components

    Science.gov (United States)

    1993-09-01

    4 List of Illustrations 1. Photograph of typical cylinders used in the present study ................................. 7 2. CCT diagram for... CCT ) diagram obtained by thermal and magnetic analyses for the high nickel (-3 percent) ASTM A723 steel. The bainite knee for the 2 percent nickel...block. Also shown is the slope giving the average cooling rate in the critical region of the CCT diagram . This average rate happens to approximately

  5. An Automated Safe-to-Mate (ASTM) Tester

    Science.gov (United States)

    Nguyen, Phuc; Scott, Michelle; Leung, Alan; Lin, Michael; Johnson, Thomas

    2013-01-01

    Safe-to-mate testing is a common hardware safety practice where impedance measurements are made on unpowered hardware to verify isolation, continuity, or impedance between pins of an interface connector. A computer-based instrumentation solution has been developed to resolve issues. The ASTM is connected to the circuit under test, and can then quickly, safely, and reliably safe-to-mate the entire connector, or even multiple connectors, at the same time.

  6. Improved ASTM G72 Test Method for Ensuring Adequate Fuel-to-Oxidizer Ratios

    Science.gov (United States)

    Juarez, Alfredo; Harper, Susana Tapia

    2016-01-01

    The ASTM G72/G72M-15 Standard Test Method for Autogenous Ignition Temperature of Liquids and Solids in a High-Pressure Oxygen-Enriched Environment is currently used to evaluate materials for the ignition susceptibility driven by exposure to external heat in an enriched oxygen environment. Testing performed on highly volatile liquids such as cleaning solvents has proven problematic due to inconsistent test results (non-ignitions). Non-ignition results can be misinterpreted as favorable oxygen compatibility, although they are more likely associated with inadequate fuel-to-oxidizer ratios. Forced evaporation during purging and inadequate sample size were identified as two potential causes for inadequate available sample material during testing. In an effort to maintain adequate fuel-to-oxidizer ratios within the reaction vessel during test, several parameters were considered, including sample size, pretest sample chilling, pretest purging, and test pressure. Tests on a variety of solvents exhibiting a range of volatilities are presented in this paper. A proposed improvement to the standard test protocol as a result of this evaluation is also presented. Execution of the final proposed improved test protocol outlines an incremental step method of determining optimal conditions using increased sample sizes while considering test system safety limits. The proposed improved test method increases confidence in results obtained by utilizing the ASTM G72 autogenous ignition temperature test method and can aid in the oxygen compatibility assessment of highly volatile liquids and other conditions that may lead to false non-ignition results.

  7. 25 CFR 36.43 - Standard XVI-Student activities.

    Science.gov (United States)

    2010-04-01

    ... § 36.43 Standard XVI—Student activities. All schools shall provide and maintain a well-balanced student..., and planned types of fund-raising activities. (c) School may participate in interscholastic sports and... sanctioned by the school. (g) All student activities involved only in fund raising are required to establish...

  8. Data development for ASTM E24.06.02 round robin program on instability prediction

    Science.gov (United States)

    Mccabe, D. E.

    1979-01-01

    Basis data for use in an ASTM E24.06.02 task group round robin activity was developed. Compact specimens were made of 2024-T351, 7075-T651 aluminum alloys, and 304 stainless steel. All were 12.7 mm thick and planar dimension variables incorporated were for 1T, 2T and 4T sizes. Representative raw data for each material and specimen size are contained herein. R-curves plotted in terms of delta a physical and delta a effective are plotted for each material.

  9. White Paper Summary of 2nd ASTM International Workshop on Hydrides in Zirconium Alloy Cladding

    Energy Technology Data Exchange (ETDEWEB)

    Sindelar, R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Louthan, M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); PNNL, B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-05-29

    This white paper recommends that ASTM International develop standards to address the potential impact of hydrides on the long term performance of irradiated zirconium alloys. The need for such standards was apparent during the 2nd ASTM International Workshop on Hydrides in Zirconium Alloy Cladding and Assembly Components, sponsored by ASTM International Committee C26.13 and held on June 10-12, 2014, in Jackson, Wyoming. The potentially adverse impacts of hydrogen and hydrides on the long term performance of irradiated zirconium-alloy cladding on used fuel were shown to depend on multiple factors such as alloy chemistry and processing, irradiation and post irradiation history, residual and applied stresses and stress states, and the service environment. These factors determine the hydrogen content and hydride morphology in the alloy, which, in turn, influence the response of the alloy to the thermo-mechanical conditions imposed (and anticipated) during storage, transport and disposal of used nuclear fuel. Workshop presentations and discussions showed that although hydrogen/hydride induced degradation of zirconium alloys may be of concern, the potential for occurrence and the extent of anticipated degradation vary throughout the nuclear industry because of the variations in hydrogen content, hydride morphology, alloy chemistry and irradiation conditions. The tools and techniques used to characterize hydrides and hydride morphologies and their impacts on material performance also vary. Such variations make site-to-site comparisons of test results and observations difficult. There is no consensus that a single material or system characteristic (e.g., reactor type, burnup, hydrogen content, end-of life stress, alloy type, drying temperature, etc.) is an effective predictor of material response during long term storage or of performance after long term storage. Multi-variable correlations made for one alloy may not represent the behavior of another alloy exposed to

  10. A Knowledge- Based Computer System for UO2 Characterization According to ASTM Requirements

    International Nuclear Information System (INIS)

    Afifi, Y.K.; El-Hakim, E.

    2000-01-01

    The uranium dioxde (UO 2 ) powder properties and the pellets fabrication processes determine the characteristics of the sintered UO 2 pellets. The powder properties include chemical and physical characteristics. The physical and chemical properties of UO 2 powder are normally checked to ensure consistency and reproducibility of the sintered UO 2 pellets. Powder characteristics are known to influence the subsequent manufacturing performance or the fuel properties. The aim of this paper is to provide the nuclear industry with a program dealing with the processes and the related requirements to determine the specifications of UO 2 powder according to the American Standards for Testing and Materials (ASTM). This program covers the physical and chemical characteristics of UO 2 powder. A group of logic flow charts dealing with the data and information available in the ASTM for each step in the characterization of UO 2 powder process and the technical assistance are constructed. These logic flow charts are collected to form a module of the software to qualify the UO 2 powder. The program contains 8 modules, each one deals with one object. This program saves time, is also considered as a collective schema for all the required UO 2 powder characterization and the related processes, and could be used as a training tool for less skilled personnel involved in UO 2 powder characterization laboratories

  11. Cavitation erosion - corrosion behaviour of ASTM A27 runner steel in natural river water

    International Nuclear Information System (INIS)

    Tôn-Thât, L

    2014-01-01

    Cavitation erosion is still one of the most important degradation modes in hydraulic turbine runners. Part of researches in this field focuses on finding new materials, coatings and surface treatments to improve the resistance properties of runners to this phenomenon. However, only few studies are focused on the deleterious effect of the environment. Actually, in some cases a synergistic effect between cavitation erosion mechanisms and corrosion kinetics can establish and increase erosion rate. In the present study, the cavitation erosion-corrosion behaviour of ASTM A27 steel in natural river water is investigated. This paper state the approach which has been used to enlighten the synergy between both phenomena. For this, a 20 kHz vibratory test according ASTM G32 standard is coupled to an electrochemical cell to be able to follow the different corrosion parameters during the tests to get evidence of the damaging mechanism. Moreover, mass losses have been followed during the exposure time. The classical degradation parameters (cumulative weight loss and erosion rate) are determined. Furthermore, a particular effort has been implemented to determine the evolution of surface damages in terms of pitting, surface cracking, material removal and surface corrosion. For this, scanning electron microscopy has been used to link the microstructure to the material removal mechanisms

  12. Comparative study between EDXRF and ASTM E572 methods using two-way ANOVA

    Science.gov (United States)

    Krummenauer, A.; Veit, H. M.; Zoppas-Ferreira, J.

    2018-03-01

    Comparison with reference method is one of the necessary requirements for the validation of non-standard methods. This comparison was made using the experiment planning technique with two-way ANOVA. In ANOVA, the results obtained using the EDXRF method, to be validated, were compared with the results obtained using the ASTM E572-13 standard test method. Fisher's tests (F-test) were used to comparative study between of the elements: molybdenum, niobium, copper, nickel, manganese, chromium and vanadium. All F-tests of the elements indicate that the null hypothesis (Ho) has not been rejected. As a result, there is no significant difference between the methods compared. Therefore, according to this study, it is concluded that the EDXRF method was approved in this method comparison requirement.

  13. 75 FR 30440 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-ASTM International

    Science.gov (United States)

    2010-06-01

    ... Production Act of 1993--ASTM International Notice is hereby given that, on May 6, 2010, pursuant to Section 6... Act''), ASTM International (``ASTM'') has filed written notifications simultaneously with the Attorney... recovery of antitrust plaintiffs to actual damages under specified circumstances. Specifically, ASTM has...

  14. An Experimental Copyright Moratorium: Study of a Proposed Solution to the Copyright Photocopying Problem. Final Report to the American Society for Testing and Materials (ASTM).

    Science.gov (United States)

    Heilprin, Laurence B.

    The Committee to Investigate Copyright Problems (CICP), a non-profit organization dedicated to resolving the conflict known as the "copyright photocopying problem" was joined by the American Society for Testing and Materials (ASTM), a large national publisher of technical and scientific standards, in a plan to simulate a long-proposed…

  15. 77 FR 37587 - Updating OSHA Standards Based on National Consensus Standards; Head Protection

    Science.gov (United States)

    2012-06-22

    ... Z89.1-2003 as Appendix E, to the main text. Adds ``ASTM E1164-02 Colorimetry--Standard Practice for... National complete citations for standards on Standards Referred to in This colorimetry, headforms, and...

  16. 77 FR 37617 - Updating OSHA Standards Based on National Consensus Standards; Head Protection

    Science.gov (United States)

    2012-06-22

    ... Z89.1-2003 as Appendix E, to the main text. Adds ``ASTM E1164-02 Colorimetry--Standard Practice for... National complete citations for standards on Standards Referred to in This colorimetry, headforms, and...

  17. Evaluation of Instrumentation for Measuring Undissolved Water in Aviation Turbine Fuels per ASTM D3240

    Science.gov (United States)

    2015-11-05

    Undissolved Water in Aviation Turbine Fuels per ASTM D3240 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Joel Schmitigal... water ) in Aviation Turbine Fuels per ASTM D3240 15. SUBJECT TERMS fuel, JP-8, aviation fuel, contamination, free water , undissolved water , Aqua-Glo 16...Michigan 48397-5000 Evaluation of Instrumentation for Measuring Undissolved Water in Aviation Turbine Fuels per ASTM D3240 Joel Schmitigal Force

  18. Corrosion resistance and microstructure of alloy 625 weld overlay on ASTM A516 grade 70

    Energy Technology Data Exchange (ETDEWEB)

    Moradi, Mohammad J. [Amirkabir Univ. of Technology, Tehran (Iran, Islamic Republic of). Petroleum Engineering Dept.; Ketabchi, Mostafa [Amirkabir Univ. of Technology, Tehran (Iran, Islamic Republic of). Mining and Metallurgical Engineering Dept.

    2016-02-01

    Nickel-based alloys are a crucial class of materials because of their excellent corrosion resistance. In the present study, single layer and two layers alloy 625 weld overlays were deposited by GTAW process on A516 grade 70 carbon steel. The dilution in terms of Fe, Ni, Mo and Nb content was calculated in 30 points of weld overlay. Microstructure observations showed that alloy 625 had austenitic structure with two types of Laves and NbC secondary phases. The uniform and pitting corrosion resistance of alloy 625 weld overlay as casted and as forged were evaluated in accordance with ASTM G48-2011 standard at different temperatures to determine the weight loss and critical pitting temperature. For achieving a better comparison, samples from alloy 625 as casted and as forged were tested under the same conditions. The results point out that single layer alloy 625 weld overlay is not suitable for chloride containing environments, two layers alloy 625 weld overlay and alloy 625 as casted have acceptable corrosion resistance and almost the same critical pitting temperature. Alloy 625 as forged has the best corrosion resistance and the highest critical pitting temperature among all test specimens. Also, the corrosion behavior was evaluated in accordance with ASTM G28 standard. The corrosion rate of single layer weld overlay was unacceptable. The average corrosion rate of two layers weld overlay and in casted condition were 35.82 and 33.01 mpy, respectively. [German] Nickellegierungen sind aufgrund ihres exzellenten Korrosionswiderstandes eine bedeutende Werkstoffklasse. In der diesem Beitrag zugrunde liegenden Studie wurden mittels WIG-Schweissens ein- und zweilagige Schweissplattierungen auf den Kohlenstoffstahl A516 (Grade 70) aufgebracht. Die Vermischung in Form des Fe-, Ni-, Mo- und Nb-Gehaltes wurde an 30 Punkten der Schweissplattierungen berechnet. Die mikrostrukturellen Untersuchungen ergaben, dass die Legierung 625 eine austenitische Struktur mit zwei Arten von

  19. Multielement analysis of biological standards by neutron activation analysis

    International Nuclear Information System (INIS)

    Nadkarni, R.A.

    1977-01-01

    Up to 28 elements were determined in two IAEA standards: Animal Muscle H4 and Fish Soluble A 6/74, and three NBS standards: Spinach: SRM-1570, Tomato Leaves: SRM-1573 and Pine Needles: SRM-1575 by instrumental neutron-activation analysis. Seven noble metals were determined in two NBS standards: Coal: SRM-1632 and Coal Fly Ash: SRM-1633 by radiochemical procedure while 11 rare earth elements were determined in NBS standard Orchard Leaves: SRM-1571 by instrumental neutron-activation analysis. The results are in good agreement with the certified and/or literature data where available. The irradiations were performed at the Cornell TRIGA Mark II nuclear reactor at a thermal neutron flux of 1-3x10 12 ncm -2 sec -1 . The short-lived species were determined after a 2-minute irradiation in the pneumatic rabbit tube, and the longer-lived species after an 8-hour irradiation in the central thimble facility. The standards and samples were counted on coaxial 56-cm 3 Ge(Li) detector. The system resolution was 1.96 keV (FWHM) with a peak to Compton ratio of 37:1 and counting efficiency of 13%, all compared to the 1.332 MeV photopeak of Co-60. (T.I.)

  20. Applying Standard Industrial Components for Active Magnetic Bearings

    Directory of Open Access Journals (Sweden)

    Bert-Uwe Koehler

    2017-02-01

    Full Text Available With the increasing number of active magnetic bearing applications, satisfying additional requirements is becoming increasingly more important. As for every technology, moving away from being a niche product and achieving a higher level of maturity, these requirements relate to robustness, reliability, availability, safety, security, traceability, certification, handling, flexibility, reporting, costs, and delivery times. Employing standard industrial components, such as those from flexible modular motion control drive systems, is an approach that allows these requirements to be satisfied while achieving rapid technological innovation. In this article, we discuss technical and non-technical aspects of using standard industrial components in magnetic bearing applications.

  1. ASTM E 1559 method for measuring material outgassing/deposition kinetics has applications to aerospace, electronics, and semiconductor industries

    Science.gov (United States)

    Garrett, J. W.; Glassford, A. P. M.; Steakley, J. M.

    1994-01-01

    The American Society for Testing and Materials has published a new standard test method for characterizing time and temperature-dependence of material outgassing kinetics and the deposition kinetics of outgassed species on surfaces at various temperatures. This new ASTM standard, E 1559(1), uses the quartz crystal microbalance (QCM) collection measurement approach. The test method was originally developed under a program sponsored by the United States Air Force Materials Laboratory (AFML) to create a standard test method for obtaining outgassing and deposition kinetics data for spacecraft materials. Standardization by ASTM recognizes that the method has applications beyond aerospace. In particular, the method will provide data of use to the electronics, semiconductor, and high vacuum industries. In ASTM E 1559 the material sample is held in vacuum in a temperature-controlled effusion cell, while its outgassing flux impinges on several QCM's which view the orifice of the effusion cell. Sample isothermal total mass loss (TML) is measured as a function of time from the mass collected on one of the QCM's which is cooled by liquid nitrogen, and the view factor from this QCM to the cell. The amount of outgassed volatile condensable material (VCM) on surfaces at higher temperatures is measured as a function of time during the isothermal outgassing test by controlling the temperatures of the remaining QCM's to selected values. The VCM on surfaces at temperatures in between those of the collector QCM's is determined at the end of the isothermal test by heating the QCM's at a controlled rate and measuring the mass loss from the end of the QCM's as a function of time and temperature. This reevaporation of the deposit collected on the QCM's is referred to as QCM thermogravimetric analysis. Isothermal outgassing and deposition rates can be determined by differentiating the isothermal TML and VCM data, respectively, while the evaporation rates of the species can be obtained as a

  2. Development of standard ionization chamber counting system for activity measurements

    International Nuclear Information System (INIS)

    Pyun, Woong Beom; Lee, Hyun Koo; Lee, Hai Yong; Park, Tae Soon

    1998-01-01

    This study is to set up the activity measuring system using a 4π γ ionization chamber as used mainly in national standards laboratories that are responsible for radionuclide metrology. The software for automatic control between the electrometer and personal computer is developed using Microsoft visual basic 4.0 and IEEE488 Interface. The reproducibility of this 4π γ ionization chamber is about 0.02% and the background current is 0.054±0.024 pA. this 4π γ ionization chamber is calibrated by 6 standard gamma emitting radionuclides from KRISS. According to the result of this study, it is revealed that this 4π γ ionization chamber counting system can be used as a secondary standard instrument for radioactivity measurement

  3. Development of standard ionization chamber counting system for activity measurements

    CERN Document Server

    Pyun, W B; Lee, H Y; Park, T S

    1998-01-01

    This study is to set up the activity measuring system using a 4 pi gamma ionization chamber as used mainly in national standards laboratories that are responsible for radionuclide metrology. The software for automatic control between the electrometer and personal computer is developed using Microsoft visual basic 4.0 and IEEE488 Interface. The reproducibility of this 4 pi gamma ionization chamber is about 0.02% and the background current is 0.054+-0.024 pA. this 4 pi gamma ionization chamber is calibrated by 6 standard gamma emitting radionuclides from KRISS. According to the result of this study, it is revealed that this 4 pi gamma ionization chamber counting system can be used as a secondary standard instrument for radioactivity measurement.

  4. Provenience studies using neutron activation analysis: the role of standardization

    International Nuclear Information System (INIS)

    Harbottle, G.

    1980-01-01

    This paper covers the historical background of chemical analysis of archaeological artifacts which dates back to 1790 to the first application of neutron activation analysis to archaeological ceramics and goes on to elaborate on the present day status of neutron activation analysis in provenience studies, and the role of standardization. In principle, the concentrations of elements in a neutron-activated specimen can be calculated from an exact knowledge of neutron flux, its intensity, duration and spectral (energy) distribution, plus an exact gamma ray count calibrated for efficiency, corrected for branching rates, etc. However, in practice it is far easier to compare one's unknown to a standard of known or assumed composition. The practice has been for different laboratories to use different standards. With analyses being run in the thousands throughout the world, a great benefit would be derived if analyses could be exchanged among all users and/or generators of data. The emphasis of this paper is on interlaboratory comparability of ceramic data; how far are we from it, what has been proposed in the past to achieve this goal, and what is being proposed. All of this may be summarized under the general heading of Analytical Quality Control - i.e., how to achieve precise and accurate analysis. The author proposes that anyone wishing to analyze archaeological ceramics should simply use his own standard, but attempt to calibrate that standard as nearly as possible to absolute (i.e., accurate) concentration values. The relationship of Analytical Quality Control to provenience location is also examined

  5. Overview (this manuscript is an overview of an ASTM symposium. The authors, John Sebroski and Mark Mason, of the overview were the co-chairs of the symposium and co-editors of the manuscripts submitted for ASTM peer review and subsequent publication in the technical proceedings for the symposium)

    Science.gov (United States)

    The Symposium on Developing Consensus Standards for Measuring Chemical Emissions from Spray Polyurethane Foam (SPF) Insulation was held on April 30th and May 1, 2015. Sponsored by ASTM Committee D22 on Air Quality, the symposium was held in Anaheim, CA, in conjunction with the st...

  6. Neutron activation analysis for certification of standard reference materials

    International Nuclear Information System (INIS)

    Capote Rodriguez, G.; Perez Zayas, G.; Hernandez Rivero, A.; Ribeiro Guevara, S.

    1996-01-01

    Neutron activation analysis is used extensively as one of the analytical techniques in the certification of standard reference materials. Characteristics of neutron activation analysis which make it valuable in this role are: accuracy multielemental capability to asses homogeneity, high sensitivity for many elements, and essentially non-destructive method. This paper report the concentrations of 30 elements (major, minor and trace elements) in four Cuban samples. The samples were irradiated in a thermal neutron flux of 10 12- 10 13 n.cm 2. s -1. The gamma ray spectra were measured by HPGe detectors and were analyzed using ACTAN program development in Center of Applied Studies for Nuclear Development

  7. Training to Support Standardization and Improvement of Configuration Management Activities

    Energy Technology Data Exchange (ETDEWEB)

    Dauber, V.; Scheffer, N.; Schoenfelder, C.

    2015-07-01

    In recent years AREVA has conducted several measures to enhance the effectiveness and efficiency of configuration management-related activities within a nuclear power plant (NPP) new build as well as modernization projects, thereby further strengthening its commitment to achieving the highest level of safety in nuclear facilities. This paper describes a new training course that shall support the standardization and improvement of configuration management activities. Recommendations will be given that should be considered when designing and developing comparable training programs to support change processes within engineering units. (Author)

  8. Biocompatibility of metal injection molded versus wrought ASTM F562 (MP35N) and ASTM F1537 (CCM) cobalt alloys.

    Science.gov (United States)

    Chen, Hao; Sago, Alan; West, Shari; Farina, Jeff; Eckert, John; Broadley, Mark

    2011-01-01

    We present a comparative analysis between biocompatibility test results of wrought and Metal Injection Molded (MIM) ASTM F562-02 UNS R30035 (MP35N) and F1537 UNS R31538 (CCM) alloy samples that have undergone the same generic orthopedic implant's mechanical, chemical surface pre-treatment, and a designed pre-testing sample preparation method. Because the biocompatibility properties resulting from this new MIM cobalt alloy process are not well understood, we conducted tests to evaluate cytotoxicity (in vitro), hemolysis (in vitro), toxicity effects (in vivo), tissue irritation level (in vivo), and pyrogenicity count (in vitro) on such samples. We show that our developed MIM MP35N and CCM materials and treatment processes are biocompatible, and that both the MIM and wrought samples, although somewhat different in microstructure and surface, do not show significant differences in biocompatibility.

  9. 24 CFR Appendix A to Part 200 - Standards Incorporated by Reference in the Minimum Property Standards for Housing (HUD Handbook...

    Science.gov (United States)

    2010-04-01

    ... 19103, Telephone (215) 299-5400. ASTM C 12-91 Standard Practice for Installing Vitrified Clay Pipe Lines... C 216-91c Standard Specification for Facing Brick (Solid Masonry Units Made from Clay or Shale) ASTM.../78 77a Cast Iron Sanitary Drainage System with Hubless Pipe and Fittings—3/28/80 78 Polyethylene (PE...

  10. Quality of Standard Reference Materials for Short Time Activation Analysis

    International Nuclear Information System (INIS)

    Ismail, S.S.; Oberleitner, W.

    2003-01-01

    Some environmental reference materials (CFA-1633 b, IAEA-SL-1, SARM-1,BCR-176, Coal-1635, IAEA-SL-3, BCR-146, and SRAM-5) were analysed by short-time activation analysis. The results show that these materials can be classified in three groups, according to their activities after irradiation. The obtained results were compared in order to create a quality index for determination of short-lived nuclides at high count rates. It was found that Cfta is not a suitable standard for determining very short-lived nuclides (half-lives<1 min) because the activity it produces is 15-fold higher than that SL-3. Biological reference materials, such as SRM-1571, SRM-1573, SRM-1575, SRM-1577, IAEA-392, and IAEA-393, were also investigated by a higher counting efficiency system. The quality of this system and its well-type detector for investigating short-lived nuclides was discussed

  11. DEVELOPMENT OF STANDARDS FOR EVALUATING THE IMPORTANCE OF CONTAMINANTS IN THE ENVIRONMENT: FIERY DISCUSSIONS, COMMON PURPOSE, A PROVEN WIN-WIN PARTNERSHIP BETWEEN THE U.S. ENVIRONMENTAL PROTECTION AGENCY AND ASTM COMMITTEE E47 (NON-PEER REV'D. JOURNAL)

    Science.gov (United States)

    The development of standards through the consensus based process is often a long and arduous process even in the best of circumstances. The impetus to develop standards is a need to obtain high quality data for the evaluation of questions that often pertain to the development of...

  12. Certification of standard reference materials employing neutron activation analysis

    International Nuclear Information System (INIS)

    Capote Rodriguez, G.; Hernandez Rivero, A.; Molina Insfran, J.; Ribeiro Guevara, S.; Santana Encinosa, C.; Perez Zayas, G.

    1997-01-01

    Neutron activation analysis (Naa) is used extensively as one of the analytical techniques in the certification of standard reference materials (Srm). Characteristics of Naa which make it valuable in this role are: accuracy; multielemental capability; ability to assess homogeneity; high sensitivity for many elements, and essentially non-destructive method. This paper reports the concentrations of thirty elements (major, minor and trace elements) in four Cuban Srm's. The samples were irradiated in a thermal neutron flux of 10 12 -10 13 neutrons.cm -2 .s -1 . The gamma-ray spectra were measured by HPGe detectors and were analysed using ACTAN program, developed in CEADEN. (author) [es

  13. DOE Technical Standards List. Directory of DOE and contractor personnel involved in non-government standards activities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-06-01

    This is a periodic report on the level of agency participation in non-Government standards activities. This technical standards list is intended to assist US Department of Energy (DOE) management and other personnel involved in the DOE technical Standards Program by identifying those participating individuals. The body of this document contains a listing of DOE employees and DOE contractors who have submitted a Record of Non-Government Standards Activity. Additional names were added from rosters supplied by non-Government standards bodies. Appendices to this document are provided to list the information by parent employment organization, by non-Government standards activity, and by the proper names of the non-Government standards organizations and committees.

  14. Sources of Confusion in the Determination of ASTM Repetitive Member Factors for the Allowable Properties of Wood Products

    Science.gov (United States)

    S. Verrill; D. Kretschmann

    2012-01-01

    It is generally accepted that there should be an upward repetitive member allowable property adjustment. ASTM D245 (2011c) and ASTM D1990 (2011b) specify a 1.15 factor for allowable bending stress. This factor is also listed in ASTM D6555 (2011a, Table 1). In this technical note, sources of confusion regarding appropriate repetitive member factors are identified. This...

  15. 76 FR 78614 - Welded ASTM A-312 Stainless Steel Pipe From South Korea and Taiwan: Continuation of Antidumping...

    Science.gov (United States)

    2011-12-19

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-580-810, A-583-815] Welded ASTM A-312... revocation of the antidumping duty orders on welded ASTM A-312 stainless steel pipe from South Korea (Korea... December 30, 1992, the Department published the antidumping duty orders on welded ASTM A-312 stainless...

  16. 76 FR 67673 - Welded ASTM A-312 Stainless Steel Pipe From South Korea and Taiwan: Final Results of Expedited...

    Science.gov (United States)

    2011-11-02

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-580-810, A-583-815] Welded ASTM A-312... the antidumping duty orders on welded ASTM A-312 stainless steel pipe from South Korea and Taiwan... duty orders on welded ASTM A-312 stainless steel pipe from South Korea and Taiwan pursuant to section...

  17. Reassessing the standard chest radiograph for intraparenchymal activity

    International Nuclear Information System (INIS)

    Putman, C.E.; Hoeck, B.

    1986-01-01

    Despite the recent enthusiasm for better means of determining the extent of the active inflammatory response in the lung parenchyma of sarcoidosis patients, standard chest radiography remains a reliable method of determining staging, and parenchymal activity as well. The chest radiograph is characteristically used to determine the severity and course of sarcoidosis, but most studies imply there are poor correlations between the radiographic opacities and other indicators such as physiological parameters, gallium scans, and computed tomography and bronchoalveolar lavage results. In this preliminary communication, the authors report a new method of determining sarcoidosis activity, as compared to gallium scan, based solely on the standard chest radiograph. This method is based on the presence or absence of air bronchogram abnormalities, peribronchial cuffing, and subpleural thickening. Adenopathy and linear, reticulonodular, and nodular opacities are not included in this system. In 85 recent studies, which were performed in 51 patients with biopsy-proven sarcoidosis, this staging method agreed with gallium scanning in 68.2% of the patients. This system failed in specific and identifiable subgroups of patients that we will delineate. The authors will not report the comparative indices with a pulmonary function analysis or bronchoalveolar lavage results. Their database has not been tabulated to conclusively present these results, but it is their belief that this methodology will probably have a better correlation with lavage results and small airway function than would results of gallium scans. Of singular importance is the fact that this method can, with a more than acceptable degree of accuracy, distinguish between ''low-intensity'' alveolitis and ''high-intensity'' alveolitis

  18. The relation between bone demineralization, physical activity and anthropometric standards

    Directory of Open Access Journals (Sweden)

    Milena Barbosa Camara

    2017-03-01

    Full Text Available This paper aimed to verify the correlation between bone mineral density and the level of physical activity, as well as the food intake and the anthropometric parameters. It intended to analyse the bone mineral density (BMD of menopausal women through the bone densitometry test (DO in the lumbar region (L1 to L4, femoral neck and total femur, and also use Bouchard’s self-recall of daily activities; employing the food record from Buker and Stuart to dose and quantify the daily intake of calcium and vitamin D. The data were analysed via Kolmogorov-Smirnov’s test, and default value of α = 0.05 was set to compare the BMD averages. It was observed that one hundred percent of the assessed individuals had a BMD level below the average fixed by WHO: 14.4% with osteopenia and 85.6% with osteoporosis; a lower BMD in the femoral area (0.721g and the biggest loss among the sedentary ones (0.698g. It was noticed that there was a correlation between the physical activities and the BMD only when associated with anthropometric standards and the daily ingestion of vitamin D.

  19. Hydrogen embrittlement of ASTM A 203 D nuclear structural steel

    International Nuclear Information System (INIS)

    Chakravartty, J.K.; Prasad, G.E.; Sinha, T.K.; Asundi, M.K.

    1986-01-01

    The influence of hydrogen on the mechanical properties of ASTM A 203 D nuclear structural steel has been studied by tension, bend and delayed-failure tests at room temperature. While the tension tests of hydrogen charged unnotched specimens reveal no change in ultimate strength and ductility, the effect of hydrogen is manifested in notched specimens (tensile and bend) as a decrease in ultimate strength (maximum load in bend test) and ductility; the effect increases with increasing hydrogen content. It is observed that for a given hydrogen concentration, the decrease in bend ductility is remarkably large compared to that in tensile ductility. Hydrogen charging does not cause any delayed-failure upto 200 h under an applied tensile stress, 0.85 times the notch tensile strength. However delayed failure occurs in hydrogen charged bend samples in less than 10 h under an applied bending load of about 0.80 times of the uncharged maximum load. Fractographs of hydrogen charged unnotched specimens show ductile dimple fracture, while those of notched tension and bend specimens under hydrogen-charged conditions show a mixture of ductile dimple and quasi-cleavage cracking. The proportion of quasi-cleavage cracking increases with increasing hydrogen content and this fracture mode is more predominant in bend specimens. The changes in tensile properties and fracture modes can reasonably be explained by existing theories of hydrogen embrittlement. An attempt is made to explain the significant difference in the embrittlement susceptibility of bend and tensile specimens in the light of difference in triaxiality and plastic zone size near the notch tip. (orig.)

  20. 78 FR 79319 - Amendment to Standards and Practices for All Appropriate Inquiries Under CERCLA

    Science.gov (United States)

    2013-12-30

    ... Standard? The ASTM E1527-13 standard is similar to the ASTM E1527-05 standard in format, process, and areas... under Section 553 of the Administrative Procedure Act (APA) for this revision to become effective immediately. Section 553(d)(3) of the APA allows an effective date less than 30 days after publication ``as...

  1. Standardization activities of the Euratom Neutron Radiography Working Group

    International Nuclear Information System (INIS)

    Domanus, J.

    1982-06-01

    In 1979 a working group on neutron radiography was formed at Euratom. The purpose of this group is the standardization of neutron radiographic methods in the field of nuclear fuel. Activities of this Neutron Radiography Working Group are revised. Classification of defects revealed by neutron radiography is illustrated in a special atlas. Beam purity and sensitivity indicators are tested together with a special calibration fuel pin. All the Euratom neutron radiography centers will perform comparative neutron radiography with those items. The measuring results obtained, using various measuring aparatus will form the basis to formulate conclusions about the best measuring methods and instruments to be used in that field. Besides the atlas of neutron radiographic findings in light water reactor fuel, the Euratom Neutron Radiogrphy Working Group has published a neutron radiography handbook in which the neutron radiography installations in the European Community are also described. (author)

  2. A trial fabrication of activity standard surface sources and positional standard surface sources for an imaging plate system

    International Nuclear Information System (INIS)

    Sato, Yasushi; Hino, Yoshio; Yamada, Takahiro; Matsumoto, Mikio

    2003-01-01

    An imaging plate system can detect low level activity, but quantitative analysis is difficult because there are no adequate standard surface sources. A new fabrication method was developed for standard surface sources by printing on a sheet of paper using an ink-jet printer with inks in which a radioactive material was mixed. The fabricated standard surface sources had high uniformity, high positional resolution arbitrary shapes and a broad intensity range. The standard sources were used for measurement of surface activity as an application. (H. Yokoo)

  3. Fracture toughness of welded joints of ASTM A543 steel plate

    International Nuclear Information System (INIS)

    Susukida, H.; Uebayashi, T.; Yoshida, K.; Ando, Y.

    1977-01-01

    Fracture toughness and weldability tests have been performed on a high strength steel which is a modification of ASTM A543 Grade B Class 1 steel, with a view to using it for nuclear reactor containment vessels. The results showed that fracture toughness of welded joints of ASTM A543 modified high strength steel is superior and the steel is suitable for manufacturing the containment vessels

  4. Integration of Nanofluids into Commercial Antifreeze Concentrates with ASTM D15 Corrosion Testing

    Science.gov (United States)

    2013-05-01

    Lockwood1 1 Valvoline New Product Development Laboratory, Ashland Consumer Markets , Lexington, Kentucky. 2 Tank Automotive Research, Development...Development Laboratory,Ashland Consumer Markets ,P.O. Box 14000,Lexington,KY,40512 8. PERFORMING ORGANIZATION REPORT NUMBER ; #23826 9. SPONSORING...Technology, Performance, and Life for Light-Duty Applications, Engine Coolant Testing: Fourth Volume, ASTM STP 1335, R.E. Beale ed., ASTM, Philadelphia

  5. Simplification and transformation of ASTM F1292 measurement procedure for fall accident injury criteria.

    Science.gov (United States)

    Kato, Maki; Shimodaira, Yoshie; Sato, Takeshi; Iida, Hiromi

    2014-01-01

    Protecting children from injuries caused by fall accidents from playground equipment is important. Therefore, measures toward minimizing the risk of fall accident injuries are required. The risk of injury can be evaluated using ASTM F1292. In this test, G-max and the HIC are used to estimate the risk of injury. However, the measurement procedure is too complicated for application to a large number of installed equipment. F1292 requires simplified by reducing the number of phases, even with a small risk of loss in accuracy. With this in mind, this study proposes a shortened measurement procedure and a transformation equation to estimate the risk as same as F1292. As the result of experiments, it was revealed that G-max and the HIC values for both procedures linearly increase with drop height. The differences in outcomes between the regression equations of the standardized procedure and those of the shortened procedure can be used as a correction value. They can be added to the value measured by the shortened procedure. This suggests that the combination of the shortened procedure and transformation equation would be equivalent to F1292, with the advantage of being more easily and efficiently applied to the evaluation of installed playground equipment.

  6. Repeatability and Reproducibility of Compression Strength Measurements Conducted According to ASTM E9

    Science.gov (United States)

    Luecke, William E.; Ma, Li; Graham, Stephen M.; Adler, Matthew A.

    2010-01-01

    Ten commercial laboratories participated in an interlaboratory study to establish the repeatability and reproducibility of compression strength tests conducted according to ASTM International Standard Test Method E9. The test employed a cylindrical aluminum AA2024-T351 test specimen. Participants measured elastic modulus and 0.2 % offset yield strength, YS(0.2 % offset), using an extensometer attached to the specimen. The repeatability and reproducibility of the yield strength measurement, expressed as coefficient of variations were cv(sub r)= 0.011 and cv(sub R)= 0.020 The reproducibility of the test across the laboratories was among the best that has been reported for uniaxial tests. The reported data indicated that using diametrically opposed extensometers, instead of a single extensometer doubled the precision of the test method. Laboratories that did not lubricate the ends of the specimen measured yield stresses and elastic moduli that were smaller than those measured in laboratories that lubricated the specimen ends. A finite element analysis of the test specimen deformation for frictionless and perfect friction could not explain the discrepancy, however. The modulus measured from stress-strain data were reanalyzed using a technique that finds the optimal fit range, and applies several quality checks to the data. The error in modulus measurements from stress-strain curves generally increased as the fit range decreased to less than 40 % of the stress range.

  7. Physical Activity Stories: Assessing the "Meaning Standard" in Physical Education

    Science.gov (United States)

    Johnson, Tyler G.

    2016-01-01

    The presence of the "meaning standard" in both national and state content standards suggests that professionals consider it an important outcome of a quality physical education program. However, only 10 percent of states require an assessment to examine whether students achieve this standard. The purpose of this article is to introduce…

  8. Experimental and numerical study of a modified ASTM C633 adhesion test for strongly-bonded coatings

    Energy Technology Data Exchange (ETDEWEB)

    Bernardie, Raphaëlle; Berkouch, Reda; Valette, Stéphane; Absi, Joseph; Lefort, Pierre [University of Limoges, Limoges Cedex (France)

    2017-07-15

    When coatings are strongly bonded to their substrates it is often difficult to measure the adhesion values. The proposed method, which is suggested naming “silver print test”, consists in covering the central part of the samples with a thin layer of silver paint, before coating. The process used for testing this new method was the Air plasma spraying (APS), and the materials used were alumina coatings on C35 steel substrates, previously pre-oxidized in CO{sub 2}. The silver painted area was composed of small grains that did not oxidize but that significantly sintered during the APS process. The silver layer reduced the surface where the coating was linked to the substrate, which allowed its debonding, using the classical adhesion test ASTM C633-13, while the direct use of this test (without silver painting) led to ruptures inside the glue used in this test. The numerical modelling, based on the finite element method with the ABAQUS software, provided results in good agreement with the experimental measurements. This concordance validated the used method and allowed accessing to the values of adherence when the experimental test ASTM C633-13 failed, because of ruptures in the glue. After standardization, the “silver print test” might be used for other kinds of deposition methods, such as PVD, CVD, PECVD.

  9. Wound Healing Activity and Chemical Standardization of Eugenia pruniformis Cambess

    Science.gov (United States)

    de Albuquerque, Ricardo Diego Duarte Galhardo; Perini, Jamila Alessandra; Machado, Daniel Escorsim; Angeli-Gamba, Thaís; Esteves, Ricardo dos Santos; Santos, Marcelo Guerra; Oliveira, Adriana Passos; Rocha, Leandro

    2016-01-01

    . Chemical standardization of the active wound healing extract was done. The total flavonoid content was 43% (w/w) and quercetin, kaempferol and hyperoside were identified as main compounds. SUMMARY Wound excision model in rats showed the potential wound healing activity of E. pruniformis by collagen deposition increase, higher levels of hidroxyproline, better tissue reorganization and complete remodeling of epidermis.Flavonoids are the main compounds of the endemic E. pruniformis and quercetin, kaempferol and hyperoside were identified in ethyl acetate extract by TLC, HPLC-PDA and HRESI-MS analysis.The ethyl acetate extract of E. pruniformis showed a potent antioxidant activity by ORAC and DPPH assays Abbreviation used: NC: Negative control, PC: Positive control, CH: Crude hydroethanolic extract, EA: Ethyl acetate extract, TE: Trolox equivalent, mg: Milligram, mM: Millimolar, mL: Milliliter, HPLC-PDA: High performance liquid chromatography with a photodiode array detector, HRESI-MS: High-resolution electrospray ionization mass spectrometry analysis, TLC: Thin layer chromatography, ORAC: Oxygen radical absorbance capacity, w/v: Weight per volume PMID:27867271

  10. Photon and proton activation analysis of iron and steel standards using the internal standard method coupled with the standard addition method

    International Nuclear Information System (INIS)

    Masumoto, K.; Hara, M.; Hasegawa, D.; Iino, E.; Yagi, M.

    1997-01-01

    The internal standard method coupled with the standard addition method has been applied to photon activation analysis and proton activation analysis of minor elements and trace impurities in various types of iron and steel samples issued by the Iron and Steel Institute of Japan (ISIJ). Samples and standard addition samples were once dissolved to mix homogeneously, an internal standard and elements to be determined and solidified as a silica-gel to make a similar matrix composition and geometry. Cerium and yttrium were used as an internal standard in photon and proton activation, respectively. In photon activation, 20 MeV electron beam was used for bremsstrahlung irradiation to reduce matrix activity and nuclear interference reactions, and the results were compared with those of 30 MeV irradiation. In proton activation, iron was removed by the MIBK extraction method after dissolving samples to reduce the radioactivity of 56 Co from iron via 56 Fe(p, n) 56 Co reaction. The results of proton and photon activation analysis were in good agreement with the standard values of ISIJ. (author)

  11. DOE technical standards list: Directory of DOE and contractor personnel involved in non-government standards activities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-05-01

    The body of this document contains a listing of DOE employees and DOE contractors who have submitted form DOE F 1300.2, Record of Non-Government Standards Activity, which is attached to the end of this document. Additional names were added from rosters supplied by non-Government standards bodies. The committees or governing bodies in which the person participates is listed after each name. An asterisk preceding the committee notation indicates that the person has identified himself or herself as the DOE representative on that committee. Appendices to this document are also provided to sort the information by the parent employment organization, by non-Government standards activity, and by the proper names of the non-Government standards organizations and committees. DOE employees and contractors listed in this technical standards list are those recorded as of May 1, 1999.

  12. Linguistic culture – active attitude toward (standard) language norm

    OpenAIRE

    Nikolovska, Violeta

    2013-01-01

    Ever since the respectable Prague School of Linguistics the issues of standard language have been getting serious treatment in linguistics. These issues are addressed in sociolinguistics, language policy and language planning - domains that are receiving the treatment of specific scientific disciplines today. This paper deals with one segment of the language standard functioning, and that is its cultivation. This segment of the functioning of the language standard begins with its codification...

  13. Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This document provides guidance in determining absorbed-dose distributions in products, materials or substances irradiated in gamma, X-ray (bremsstrahlung) and electron beam facilities. Note 1—For irradiation of food and the radiation sterilization of health care products, other specific ISO and ISO/ASTM standards containing dose mapping requirements exist. For food irradiation, see ISO/ASTM 51204, Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing and ISO/ASTM 51431, Practice for Dosimetry in Electron and Bremsstrahlung Irradiation Facilities for Food Processing. For the radiation sterilization of health care products, see ISO 11137: 1995, Sterilization of Health Care Products Requirements for Validation and Routine Control Radiation Sterilization. In those areas covered by ISO 11137, that standard takes precedence. ISO/ASTM Practice 51608, ISO/ASTM Practice 51649, and ISO/ASTM Practice 51702 also contain dose mapping requirements. 1.2 Methods of analyzing the dose map data ar...

  14. 78 FR 21850 - Federal Motor Vehicle Safety Standards; Matters Incorporated by Reference

    Science.gov (United States)

    2013-04-12

    ... to the 1985 Annual Book of ASTM Standards, Vol. 05.04, ``Test Methods for Rating Motor, Diesel... for Rating Motor, Diesel, Aviation Fuels, A2. Reference Materials and Blending Accessories, (``ASTM... [Docket No. NHTSA-2011-0185] RIN 2127-AL25 Federal Motor Vehicle Safety Standards; Matters Incorporated by...

  15. An investigation of force components in orthogonal cutting of medical grade cobalt-chromium alloy (ASTM F1537).

    Science.gov (United States)

    Baron, Szymon; Ahearne, Eamonn

    2017-04-01

    An ageing population, increased physical activity and obesity are identified as lifestyle changes that are contributing to the ongoing growth in the use of in-vivo prosthetics for total hip and knee arthroplasty. Cobalt-chromium-molybdenum (Co-Cr-Mo) alloys, due to their mechanical properties and excellent biocompatibility, qualify as a class of materials that meet the stringent functional requirements of these devices. To cost effectively assure the required dimensional and geometric tolerances, manufacturers rely on high-precision machining. However, a comprehensive literature review has shown that there has been limited research into the fundamental mechanisms in mechanical cutting of these alloys. This article reports on the determination of the basic cutting-force coefficients in orthogonal cutting of medical grade Co-Cr-Mo alloy ASTM F1537 over an extended range of cutting speeds ([Formula: see text]) and levels of undeformed chip thickness ([Formula: see text]). A detailed characterisation of the segmented chip morphology over this range is also reported, allowing for an estimation of the shear plane angle and, overall, providing a basis for macro-mechanic modelling of more complex cutting processes. The results are compared with a baseline medical grade titanium alloy, Ti-6Al-4V ASTM F136, and it is shown that the tangential and thrust-force components generated were, respectively, ≈35% and ≈84% higher, depending primarily on undeformed chip thickness but with some influence of the cutting speed.

  16. European standardization activities on safety of liquid helium cryostats

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    This talk gives a general overview on the challenges of designing safety units for liquid helium cryostats with regard to existing industry standards. It reviews the work of a national working group that published the technical guideline DIN SPEC 4683 in April 2015, which is dedicated to the particular conditions in liquid helium cryostats. Based on both this guideline and equivalent documents from e.g. CEA, CERN, a working group is being formed at the European Committee for Standardization, associated to CEN/TC 268, which will work on a European standard on safety of liquid helium cryostats. The actual status and the schedule of this project are presented.

  17. Standardization by ISO to Ensure the Sustainability of Space Activities

    Science.gov (United States)

    Kato, A.; Lazare, B.; Oltrogge, D.; Stokes, H.

    2013-08-01

    The ISO / Technical Committee 20 / Sub-committee 14 develops debris-related standards and technical reports to mitigate debris and help ensure mission and space sustainability. While UN Guidelines and the IADC Guidelines encourage national governments and agencies to promote debris mitigation design and operation, the ISO standards will help the global space industry promote and sustain its space-related business. In this paper the scope and status of each ISO standard is discussed within an overall framework. A comparison with international guidelines is also provided to demonstrate the level of consistency. Finally, as a case study, the ISO standards are applied to a CubeSat mission, thus demonstrating their usability on a relatively recent and popular class of satellite.

  18. free radical scavenging and cytotoxic activity of standardized extracts

    African Journals Online (AJOL)

    Ledy

    cancer cell line HeLa of five commercial standardized extracts rich in phenolic compounds: red wine ... and used as feedstock in nutritional supplement manu- .... pharmaceutical, food, or cosmetic products, as ..... cancer stem-like cell.

  19. DOE technical standards list: Directory of DOE and contractor personnel involved in non-government standards activities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-08-01

    The body of this document contains a listing of DOE employees and DOE contractors who have submitted form DOE F 1300.2, Record of Non-Government Standards Activity, which is attached to the end of this document and to DOE Order 1300.2A. Additional names were added from rosters supplied by non-Government standards bodies. The committees or governing bodies in which the person participates is listed after each name. An asterisk preceding the committee notation indicates that the person has identified himself or herself as the DOE representative on that committee. Appendices to this document are also provided to sort the information by the parent employment organization, by non-Government standards activity, and by the proper names of the non-Government standards organizations and committees. DOE employees and contractors listed in this TSL are those recorded as of July 1, 1996.

  20. Activity standardization of 134Cs and 137Cs

    International Nuclear Information System (INIS)

    Sochorová, Jana; Auerbach, Pavel

    2014-01-01

    The paper presents the results from a primary standardization of 137 Cs using two independent methods – efficiency tracing using PC-NaI coincidence and the TDCR method. The nuclides 60 Co and 134 Cs were used as the tracers. Primary standardization of the 134 Cs is also discussed. The efficiency extrapolation was carried out by measuring samples of varying mass and using the wet extrapolation method. The results obtained are in good agreement; the differences did not exceed 0.5%. The advantages, pitfalls and also possibilities for improvement of the procedures are discussed

  1. Combating Wear of ASTM A36 Steel by Surface Modification Using Thermally Sprayed Cermet Coatings

    OpenAIRE

    Shibe, Vineet; Chawla, Vikas

    2016-01-01

    Thermal spray coatings can be applied economically on machine parts to enhance their requisite surface properties like wear, corrosion, erosion resistance, and so forth. Detonation gun (D-Gun) thermal spray coatings can be applied on the surface of carbon steels to improve their wear resistance. In the present study, alloy powder cermet coatings WC-12% Co and Cr3C2-25% NiCr have been deposited on ASTM A36 steel with D-Gun thermal spray technique. Sliding wear behavior of uncoated ASTM A36 ste...

  2. Directory of DOE and contractor personnel involved in non-government standards activities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    This document contains a listing of DOE employees and DOE contractors who have submitted form DOE F 1300.2, Record of Non-Government Standards Activity. Additional names were added from rosters supplied by non-Government standards bodies.

  3. 30 CFR 229.123 - Standards for audit activities.

    Science.gov (United States)

    2010-07-01

    ... 229.123 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR MINERALS REVENUE... required, including a knowledge of accounting, auditing, agency regulations, and industry operations. (ii... statement of standards. (iii) The auditor's report should contain a statement of positive assurance on those...

  4. Photospheric activity of the Sun with VIRGO and GOLF. Comparison with standard activity proxies

    Science.gov (United States)

    Salabert, D.; García, R. A.; Jiménez, A.; Bertello, L.; Corsaro, E.; Pallé, P. L.

    2017-12-01

    We study the variability of solar activity using new photospheric proxies originally developed for the analysis of stellar magnetism with the CoRoT and Kepler photometric observations. These proxies were obtained by tracking the temporal modulations in the observations associated with the spots and magnetic features as the Sun rotates. We analyzed 21 yr of observations, spanning solar cycles 23 and 24, collected by the space-based photometric VIRGO and radial velocity GOLF instruments on board the SoHO satellite. We then calculated the photospheric activity proxy Sph is for each of the three VIRGO photometers and the associated Svel proxy from the radial velocity GOLF observations. Comparisons with several standard solar activity proxies sensitive to different layers of the Sun demonstrate that these new activity proxies, Sph and Svel, provide a new manner to monitor solar activity. We show that both the long- and short-term magnetic variabilities respectively associated with the 11-yr cycle and the quasi-biennial oscillation are well monitored, and that the magnetic field interaction between the subsurface, photosphere, and chromosphere of the Sun was modified between Cycle 24 and Cycle 23. Furthermore, the photometric proxies show a wavelength dependence of the response function of the solar photosphere among the three channels of the VIRGO photometers, providing inputs for the study of the stellar magnetism of Sun-like stars.

  5. DOE standard: Integration of environment, safety, and health into facility disposition activities. Volume 1 of 2: Technical standard

    International Nuclear Information System (INIS)

    1998-05-01

    This Department of Energy (DOE) technical standard (referred to as the Standard) provides guidance for integrating and enhancing worker, public, and environmental protection during facility disposition activities. It provides environment, safety, and health (ES and H) guidance to supplement the project management requirements and associated guidelines contained within DOE O 430.1A, Life-Cycle Asset Management (LCAM), and amplified within the corresponding implementation guides. In addition, the Standard is designed to support an Integrated Safety Management System (ISMS), consistent with the guiding principles and core functions contained in DOE P 450.4, Safety Management System Policy, and discussed in DOE G 450.4-1, Integrated Safety Management System Guide. The ISMS guiding principles represent the fundamental policies that guide the safe accomplishment of work and include: (1) line management responsibility for safety; (2) clear roles and responsibilities; (3) competence commensurate with responsibilities; (4) balanced priorities; (5) identification of safety standards and requirements; (6) hazard controls tailored to work being performed; and (7) operations authorization. This Standard specifically addresses the implementation of the above ISMS principles four through seven, as applied to facility disposition activities

  6. Comparative field permeability measurement of permeable pavements using ASTM C1701 and NCAT permeameter methods.

    Science.gov (United States)

    Li, Hui; Kayhanian, Masoud; Harvey, John T

    2013-03-30

    Fully permeable pavement is gradually gaining support as an alternative best management practice (BMP) for stormwater runoff management. As the use of these pavements increases, a definitive test method is needed to measure hydraulic performance and to evaluate clogging, both for performance studies and for assessment of permeability for construction quality assurance and maintenance needs assessment. Two of the most commonly used permeability measurement tests for porous asphalt and pervious concrete are the National Center for Asphalt Technology (NCAT) permeameter and ASTM C1701, respectively. This study was undertaken to compare measured values for both methods in the field on a variety of permeable pavements used in current practice. The field measurements were performed using six experimental section designs with different permeable pavement surface types including pervious concrete, porous asphalt and permeable interlocking concrete pavers. Multiple measurements were performed at five locations on each pavement test section. The results showed that: (i) silicone gel is a superior sealing material to prevent water leakage compared with conventional plumbing putty; (ii) both methods (NCAT and ASTM) can effectively be used to measure the permeability of all pavement types and the surface material type will not impact the measurement precision; (iii) the permeability values measured with the ASTM method were 50-90% (75% on average) lower than those measured with the NCAT method; (iv) the larger permeameter cylinder diameter used in the ASTM method improved the reliability and reduced the variability of the measured permeability. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. The Status of silicosis in the world: Feedback on the ASTM Silica Symposium

    CSIR Research Space (South Africa)

    Pretorius, CJ

    2013-06-01

    Full Text Available The second ASTM Silica Symposium was held in Oct 2012 where speakers reported on the status of silicosis in their respective countries. Speakers reported on findings of research that they carried out on sampling equipment and analytical techniques...

  8. Combating Wear of ASTM A36 Steel by Surface Modification Using Thermally Sprayed Cermet Coatings

    Directory of Open Access Journals (Sweden)

    Vineet Shibe

    2016-01-01

    Full Text Available Thermal spray coatings can be applied economically on machine parts to enhance their requisite surface properties like wear, corrosion, erosion resistance, and so forth. Detonation gun (D-Gun thermal spray coatings can be applied on the surface of carbon steels to improve their wear resistance. In the present study, alloy powder cermet coatings WC-12% Co and Cr3C2-25% NiCr have been deposited on ASTM A36 steel with D-Gun thermal spray technique. Sliding wear behavior of uncoated ASTM A36 steel and D-Gun sprayed WC-12% Co and Cr3C2-25% NiCr coatings on base material is observed on a Pin-On-Disc Wear Tester. Sliding wear performance of WC-12% Co coating is found to be better than the Cr3C2-25% NiCr coating. Wear performance of both these cermet coatings is found to be better than uncoated ASTM A36 steel. Thermally sprayed WC-12% Co and Cr3C2-25% NiCr cermet coatings using D-Gun thermal spray technique is found to be very useful in improving the sliding wear resistance of ASTM A36 steel.

  9. Autogenous shrinkage of Ducorit S5R ASTM C 1698-09 test method

    DEFF Research Database (Denmark)

    Damkilde, Lars

    The report deals with experimental measurement of autogenous shrinkage of Ducorit S5R according to the test method ASTM C 1698-09. This test method measures the bulk strain of a sealed cementitious specimen, at constant temperature and not subjected to external forces, from the time of final...

  10. Regulatory Endorsement Activities for ASME Nuclear Codes and Standards

    International Nuclear Information System (INIS)

    West, Raymond A.

    2006-01-01

    The ASME Board on Nuclear Codes and Standards (BNCS) has formed a Task Group on Regulatory Endorsement (TG-RE) that is currently in discussions with the United States Nuclear Regulatory Commission (NRC) to look at suggestions and recommendations that can be used to help with the endorsement of new and revised ASME Nuclear Codes and Standards (NC and S). With the coming of new reactors in the USA in the very near future we need to look at both the regulations and all the ASME NC and S to determine where we need to make changes to support these new plants. At the same time it is important that we maintain our operating plants while addressing ageing management needs of our existing reactors. This is going to take new thinking, time, resources, and money. For all this to take place the regulations and requirements that we use must be clear concise and necessary for safety and to that end both the NRC and ASME are working together to make this happen. Because of the influence that the USA has in the world in dealing with these issues, this paper is written to inform the international nuclear engineering community about the issues and what actions are being addressed under this effort. (author)

  11. COMPETITION BEETWEN DYNAMIC RECUPERATION AND RECRYSTALLIZATION OF ASTM F 138 AUSTENITIC STAINLESS STEEL UTILIZED IN MEDICAL DEVICES

    Directory of Open Access Journals (Sweden)

    Fabio Henrique Casarini Geronimo

    2013-06-01

    Full Text Available ASTM F 138 austenitic stainless steel has being used in the manufacture of orthopedical devices by hot forging. In this work, the flow stress curves are determined by hot torsion tests in a wide range of temperatures and strain rates. With the observed microestrutural evolution by optical microscopy in different hot forming conditions in addiction with EBSD (Electron Backscatter Diffraction techniques it is possible to obtained the recrystallized volume fraction and the misorientation angles of the samples. Due to the intermediate level of stacking fault energy of this material, during the dynamic softening occurs a competition between recrystallization and recovery. The aim of this work is to identify the softening mechanisms in this stainless steel, as well as in which hot work conditions they become more active.

  12. Guidelines on Active Content and Mobile Code: Recommendations of the National Institute of Standards and Technology

    National Research Council Canada - National Science Library

    Jansen, Wayne

    2001-01-01

    .... One such category of technologies is active content. Broadly speaking, active content refers to electronic documents that, unlike past character documents based on the American Standard Code for Information Interchange (ASCII...

  13. 75 FR 48593 - Pipeline Safety: Periodic Updates of Regulatory References to Technical Standards and...

    Science.gov (United States)

    2010-08-11

    ... (ASTM): ASTM A53/A53M-07 (2007), ``Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless'' (September 1, 2007). Replaces IBR: 2004 edition; Referenced in 49 CFR 192...), we clarify that cast iron, malleable iron, or ductile iron may be used in the valve ball or plug...

  14. Spray Drift Reduction Evaluations of Spray Nozzles Using a Standardized Testing Protocol

    Science.gov (United States)

    2010-07-01

    Drop Size Characteristics in a Spray Using Optical Nonimaging Light-Scattering Instruments,” Annual Book of ASTM Standards, Vol. 14-02, ASTM...Test Method for Determining Liquid Drop Size Characteristics in a Spray Using Optical Non- imaging Light-Scattering Instruments 22. AGDISP Model

  15. Wound healing activity and chemical standardization of Eugenia pruniformis Cambess

    OpenAIRE

    Ricardo Diego Duarte Galhardo de Albuquerque; Jamila Alessandra Perini; Daniel Escorsim Machado; Thaís Angeli-Gamba; Ricardo dos Santos Esteves; Marcelo Guerra Santos; Adriana Passos Oliveira; Leandro Rocha

    2016-01-01

    Background: Eugenia pruniformis is an endemic species from Brazil. Eugenia genus has flavonoids as one of the remarkable chemical classes which are related to the improvement of the healing process. Aims: To evaluate of wound healing activity of E. pruniformis leaves and to identify and quantify its main flavonoids compounds. Materials And Methods: Wound excision model in rats was used to verify the hydroethanolic and ethyl acetate extracts potential. The animals were divided in four groups o...

  16. 77 FR 75198 - Standard Format and Content for Post-Shutdown Decommissioning Activities Report

    Science.gov (United States)

    2012-12-19

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0299] Standard Format and Content for Post-Shutdown... regulatory guide (DG), DG-1272, ``Standard Format and Content for Post-shutdown Decommissioning Activities... Content for Post-shutdown Decommissioning Activities Report,'' which was issued in July 2000. DG-1271...

  17. 78 FR 38739 - Standard Format and Content for Post-Shutdown Decommissioning Activities Report

    Science.gov (United States)

    2013-06-27

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0299] Standard Format and Content for Post-Shutdown Decommissioning Activities Report AGENCY: Nuclear Regulatory Commission. ACTION: Regulatory guide; issuance..., ``Standard Format and Content for Post-shutdown Decommissioning Activities Report.'' This guide describes a...

  18. Materials for Consideration in Standardized Canister Design Activities.

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, Charles R.; Ilgen, Anastasia Gennadyevna; Enos, David George; Teich-McGoldrick, Stephanie; Hardin, Ernest

    2014-10-01

    This document identifies materials and material mitigation processes that might be used in new designs for standardized canisters for storage, transportation, and disposal of spent nuclear fuel. It also addresses potential corrosion issues with existing dual-purpose canisters (DPCs) that could be addressed in new canister designs. The major potential corrosion risk during storage is stress corrosion cracking of the weld regions on the 304 SS/316 SS canister shell due to deliquescence of chloride salts on the surface. Two approaches are proposed to alleviate this potential risk. First, the existing canister materials (304 and 316 SS) could be used, but the welds mitigated to relieve residual stresses and/or sensitization. Alternatively, more corrosion-resistant steels such as super-austenitic or duplex stainless steels, could be used. Experimental testing is needed to verify that these alternatives would successfully reduce the risk of stress corrosion cracking during fuel storage. For disposal in a geologic repository, the canister will be enclosed in a corrosion-resistant or corrosion-allowance overpack that will provide barrier capability and mechanical strength. The canister shell will no longer have a barrier function and its containment integrity can be ignored. The basket and neutron absorbers within the canister have the important role of limiting the possibility of post-closure criticality. The time period for corrosion is much longer in the post-closure period, and one major unanswered question is whether the basket materials will corrode slowly enough to maintain structural integrity for at least 10,000 years. Whereas there is extensive literature on stainless steels, this evaluation recommends testing of 304 and 316 SS, and more corrosion-resistant steels such as super-austenitic, duplex, and super-duplex stainless steels, at repository-relevant physical and chemical conditions. Both general and localized corrosion testing methods would be used to

  19. Impact of heat treatment on HSS cutting tool (ASTM A600) and its behaviour during machining of mild steel (ASTM A36)

    Science.gov (United States)

    Afolalu, S. A.; Abioye, O. P.; Salawu, E. Y.; Okokpujie, I. P.; Abioye, A. A.; Omotosho, O. A.; Ajayi., O. O.

    2018-04-01

    Carburization is one the best heat treatment that responded well to hardening with Palm Kernel Shell giving the best hardness value. This work studied the influence of carburization on HSStool(ASTM A600) and its behaviour during machining of mild steel (ASTM A36). Composition of the samples (12 pieces of 180 × 12 × 12 mm) HSS tools were checked using UV-VIS spectrometer and the tools were carburized with PKS at holding temperatures and time of 800, 850, 900, 950 °C and 60,90 120 minutes using muffle furnance. The micro structural analysis, surface and core hardnessof the treated samples gave better results than the untreated samples when checked withsoft driven and optical microscope. It wasalso observed that increase in the feed rate and depth for length of cut of 50 mm significantly reduces the wear progression and thereby gave best machining time at maximum carburizing temperature and time(950 °C / 120 minutes) when it was used to cut mild steelon the lathe machine.

  20. Synthetic multielement standards used for instrumental neutron activation analysis as rock imitations

    International Nuclear Information System (INIS)

    Leypunskaya, D.I.; Drynkin, V.I.; Belenky, B.V.; Kolomijtsev, M.A.; Dundera, V.Yu.; Pachulia, N.V.

    1975-01-01

    Complex (multielemental) standards representing microelement composition of standard rocks such as trap ST-1 (USSR), gabbrodiorite SGD-1 (USSR), albitized granite SG-1 (USSR), basalt BCR-1 (USA) and granodiorite GSP-1 (USA) have been synthesized. It has been shown that the concentration of each microelement in the synthetic standards can be given with a high precision. Comparative investigation has been carried out of the synthetic imitations and the above natural standard rocks. It has been found that the result of the instrumental neutron activation analysis using the synthetic standards is as good as in the case when natural standard rocks are used. The results obtained have been also used for substantiation of the versatility of the method used for standard preparation, i.e. a generalization has been made of a possibility of using this method for the preparation of synthetic standards representing the microelement composition of any natural rocks with various compositions and concentrations of microelements. (T.G.)

  1. Standard Guide for Testing Polymer Matrix Composite Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This guide summarizes the application of ASTM standard test methods (and other supporting standards) to continuous-fiber reinforced polymer matrix composite materials. The most commonly used or most applicable ASTM standards are included, emphasizing use of standards of Committee D30 on Composite Materials. 1.2 This guide does not cover all possible standards that could apply to polymer matrix composites and restricts discussion to the documented scope. Commonly used but non-standard industry extensions of test method scopes, such as application of static test methods to fatigue testing, are not discussed. A more complete summary of general composite testing standards, including non-ASTM test methods, is included in the Composite Materials Handbook (MIL-HDBK-17). Additional specific recommendations for testing textile (fabric, braided) composites are contained in Guide D6856. 1.3 This guide does not specify a system of measurement; the systems specified within each of the referenced standards shall appl...

  2. A new method to determine J0-integral values (ASTM E 813) without any auxiliary equipment

    International Nuclear Information System (INIS)

    Ullrich, G.; Krompholz, K.

    1987-01-01

    In this contribution the path independent J-integral according to J.R. Rice, respective J.D. Landes and J.A. Begley due to ASTME 813 is calculated by the product J pl = d v J el for 3 point bend type specimen. Here d v is the load point displacement up to the point of the onset of stable crack growth V, which is taken from the load versus load point displacement diagram and J el a value which is equivalent to K 2 /E, where K is the stress intensity factor (ASTME 399) and E is Young's modulus. The advantage of the new procedure is the simplicity of the test arrangement and of the evaluation with the determination of initiation point V without computer or other auxiliary equipment. (orig.) [de

  3. Reactor pressure vessel steels ASTM A533B and A508 Cl.2

    International Nuclear Information System (INIS)

    Pelli, R.; Kemppainen, M.; Toerroenen, K.

    1979-11-01

    This report presents the tensile test results of steels ASTM A533B and A508 Cl.2 obtained in connection with a programme initiated to gather and create information needed for the assessment of the structural integrity of the reactor pressure vessels. The tensile properties were studied between -196 and 300 degC varying austenitizing and tempering temperatures and having two different carbon contents for the heats of A533B. (author)

  4. Neutron activation analysis of reference materials by the k sub 0 standardization and relative methods

    Energy Technology Data Exchange (ETDEWEB)

    Freitas, M C; Martinho, E [LNETI/ICEN, Sacavem (Portugal)

    1989-04-15

    Instrumental neutron activation analysis with the k{sub o}-standardization method was applied to eight geological, environmental and biological reference materials, including leaves, blood, fish, sediments, soils and limestone. To a first approximation, the results were normally distributed around the certified values with a standard deviation of 10%. Results obtained by using the relative method based on well characterized multi-element standards for IAEA CRM Soil-7 are reported.

  5. The preparation of synthetic standards for use in instrumental neutron-activation analysis

    International Nuclear Information System (INIS)

    Eddy, B.T.; Watterson, J.I.W.; Erasmus, C.S.

    1979-01-01

    An account is given of the formulation and preparation of synthetic standards suitable for the routine analysis of minerals, ores, and ore concentrates by instrumental neutron activation. Fifteen standards were prepared, each containing from one to seven elements. The standards contain forty-four elements that produce isotopes with half-lives longer than 12 hours. An evaluation of the accuracy and precision of the method of preparation is given

  6. 78 FR 45051 - Small Business Size Standards; Support Activities for Mining; Correction

    Science.gov (United States)

    2013-07-26

    ... Regulations by increasing small business size standards for three of the four industries in North American... SMALL BUSINESS ADMINISTRATION 13 CFR Part 121 RIN 3245-AG44 Small Business Size Standards; Support Activities for Mining; Correction AGENCY: U.S. Small Business Administration. ACTION: Final rule; correction...

  7. Pesticide Active Ingredient Production Industry: National Emission Standards for Hazardous Air Pollutants (NESHAP)

    Science.gov (United States)

    This action promulgates national emission standards for hazardous air pollutants (NESHAP) for the pesticide active ingredient (PAI) production source category under section 112 of the Clean Air Act as amended (CAA or Act).

  8. Activities of the data centers on atomic spectroscopy at the National Institute of Standards and Technology

    International Nuclear Information System (INIS)

    Wiese, W.L.

    1990-01-01

    The activities concerning Atomic Energy Levels and Wavelengths, Atomic Transition Probabilities and Spectral Line Shapes and Shifts at the National Institute of Standards and Technology (Gaithersburg, USA) are listed together with the corresponding lists of publications

  9. 77 FR 27428 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe (Over 41/2

    Science.gov (United States)

    2012-05-10

    ... (``ASME'') code stress levels. Alloy pipes made to ASTM A-335 standard must be used if temperatures and stress levels exceed those allowed for ASTM A-106. Seamless pressure pipes sold in the United States are..., or pressure pipe applications. B. Finished and unfinished oil country tubular goods (``OCTG''), if...

  10. 76 FR 66688 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe (Over 41/2

    Science.gov (United States)

    2011-10-27

    ... (``ASME'') code stress levels. Alloy pipes made to ASTM A-335 standard must be used if temperatures and stress levels exceed those allowed for ASTM A-106. Seamless pressure pipes sold in the United States are..., or pressure pipe applications. B. Finished and unfinished oil country tubular goods (``OCTG''), if...

  11. 76 FR 47555 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line and Pressure Pipe From Japan...

    Science.gov (United States)

    2011-08-05

    ... Engineers (``ASME'') code stress levels. Alloy pipes made to ASTM A-335 standard must be used if temperatures and stress levels exceed those allowed for ASTM A-106. Seamless pressure pipes sold in the United..., or pressure pipe applications. B. Finished and unfinished oil country tubular goods (``OCTG''), if...

  12. Ductile fracture toughness of heavy section pressure vessel steel plate. A specimen-size study of ASTM A 533 steels

    International Nuclear Information System (INIS)

    Williams, J.A.

    1979-09-01

    The ductile fracture toughness, J/sub Ic/, of ASTM A 533, Grade B, Class 1 and ASTM A 533, heat treated to simulate irradiation, was determined for 10- to 100-mm thick compact specimens. The toughness at maximum specimen load was also measured to determine the conservatism of J/sub Ic/. The toughness of ASTM A 533, Grade B, Class 1 steel was 349 kJ/m 2 and at the equivalent upper shelf temperature, the heat treated material exhibited 87 kJ/m 2 . The maximum load fracture toughness was found to be linearly proportional to specimen size, and only specimens which failed to meet ASTM size criteria exhibited maximum load toughness less than J/sub Ic/

  13. Measuring the activity of BioBrick promoters using an in vivo reference standard

    Directory of Open Access Journals (Sweden)

    Kelly Jason R

    2009-03-01

    Full Text Available Abstract Background The engineering of many-component, synthetic biological systems is being made easier by the development of collections of reusable, standard biological parts. However, the complexity of biology makes it difficult to predict the extent to which such efforts will succeed. As a first practical example, the Registry of Standard Biological Parts started at MIT now maintains and distributes thousands of BioBrick™ standard biological parts. However, BioBrick parts are only standardized in terms of how individual parts are physically assembled into multi-component systems, and most parts remain uncharacterized. Standardized tools, techniques, and units of measurement are needed to facilitate the characterization and reuse of parts by independent researchers across many laboratories. Results We found that the absolute activity of BioBrick promoters varies across experimental conditions and measurement instruments. We choose one promoter (BBa_J23101 to serve as an in vivo reference standard for promoter activity. We demonstrated that, by measuring the activity of promoters relative to BBa_J23101, we could reduce variation in reported promoter activity due to differences in test conditions and measurement instruments by ~50%. We defined a Relative Promoter Unit (RPU in order to report promoter characterization data in compatible units and developed a measurement kit so that researchers might more easily adopt RPU as a standard unit for reporting promoter activity. We distributed a set of test promoters to multiple labs and found good agreement in the reported relative activities of promoters so measured. We also characterized the relative activities of a reference collection of BioBrick promoters in order to further support adoption of RPU-based measurement standards. Conclusion Relative activity measurements based on an in vivoreference standard enables improved measurement of promoter activity given variation in measurement

  14. JST Thesaurus Headwords and Synonyms: ASTM [MeCab user dictionary for science technology term[Archive

    Lifescience Database Archive (English)

    Full Text Available MeCab user dictionary for science technology term ASTM 名詞 一般 * * * * 米国材料試験協会 ベイコクザ...イリョウシケンキョウカイ ベイコクザイリョーシケンキョーカイ Thesaurus2015 200906091611619997 C IA02 UNKNOWN_1 ASTM

  15. Determination of gold and silver in geological standard samples MGI by instrument neutron activation analysis

    International Nuclear Information System (INIS)

    Lu Huijiuan; Zhou; Yunlu

    1987-01-01

    Gold and silver in geological standard samples MGI were determined by instrument neutron activation analysis. The various interferences of nuclides were considered. Corrected factors of the geometry in different positions have been determined. Using the geological standard sample MGM and radiochemical separation neutron activation method as reference, the reliability of this method is proved. Gold content in samples is 0.4-0.009 g/t, silver content is 9-0.3 g/t. Standard deviation is less than 3.5%, the precision of the measurement is 4.8-11.6%

  16. Anti-inflammatory and antinociceptive activities of Phyllanthus niruri spray-dried standardized extract

    Directory of Open Access Journals (Sweden)

    Cínthia R. C. Porto

    2013-02-01

    Full Text Available Phyllanthus niruri L., Euphorbiaceae, spray-dried standardized extract was studied for its anti-inflammatory and antinociceptive activities in adult albino rats and mice. The anti-inflammatory effect of spray-dried standardized extract was observed in carrageenan-induced paw edema and thioglycolate-induced leukocyte migration, while antinociceptive effects were observed using Randall & Selitto, tail flick, and hot plate tests. This study showed that intraperitoneal spray-dried standardized extract at 100, 200, 800, or 1600 mg/kg reduced the vascular response in the inflammatory process of paw edema induced by 1% carrageenan. Oral spray-dried standardized extract at 100 or 200 mg/kg inhibited leukocyte migration to the site of inflammation induced by 3% thioglycolate. In rats, at 100 and 200 mg/kg intraperitoneally, the extract exhibited a marked peripheral analgesic effect in a Randall & Selitto assay and showed significant central analgesic activity in a hot plate and tail flick assay. In conclusion, this study suggested that Phyllanthus niruri spray-dried standardized extract has potent inflammatory and antinociceptive activities and that these activities are not modified by standard drying process, making it feasible to use the dry extract standardized to obtain a phytotherapic preparation and thus validating its use for the treatment of pain and inflammation disorders.

  17. Studies on the welding of heavy-section ASTM A542 Cl. 1 steel for large-sized pressure vessels

    International Nuclear Information System (INIS)

    Shimizu, Shigeki; Aota, Toshiichi; Kasahara, Masayuki

    1977-01-01

    ASTM A 542, Cl. 1 steel was developed and standardized recently, and is excellent in the high temperature strength and toughness as compared with conventionally used A 387, Grade 22 steel, accordingly the application to large pressure vessels is planned. This steel is a low alloy steel, and in case of large thickness, the possibility of cracking in the welded part is large. Also many times of annealing are required for the prevention of welding cracking, the relieving of residual stress, and the softening of hardened portion, but the possibility of cracking during stress-relieving annealing is large. In this study, Tekken type cracking test was carried out by coated electrode welding, and restricted cracking test was carried out by submerged arc welding of the A 542, Cl. 1 steel and A 387, Grade 22 steel, thus the welding cracking property was investigated, and the optimal welding conditions were selected. Also the test of cracking during the stress-relieving annealing of both steels was carried out, and the method of preventing the cracking was studied. The optimal conditions of stress-relieving annealing were selected, and the mechanism of the cracking was clarified. The mechanical properties of the joints welded and stress-relieved under the selected conditions were confirmed. (Kako, I.)

  18. Influence of Chromium-Cobalt-Molybdenum Alloy (ASTM F75) on Bone Ingrowth in an Experimental Animal Model.

    Science.gov (United States)

    Zuchuat, Jésica; Berli, Marcelo; Maldonado, Ysaí; Decco, Oscar

    2017-12-26

    Cr-Co-Mo (ASTM F75) alloy has been used in the medical environment, but its use as a rigid barrier membrane for supporting bone augmentation therapies has not been extensively investigated. In the present study, Cr-Co-Mo membranes of different heights were placed in New Zealand white, male rabbit tibiae to assess the quality and volume of new bone formation, without the use of additional factors. Animals were euthanized at 20, 30, 40, and 60 days. Bone formation was observed in all of the cases, although the tibiae implanted with the standard membranes reached an augmentation of bone volume that agreed with the density values over the timecourse. In all cases, plasmatic exudate was found under the membrane and in contact with the new bone. Histological analysis indicated the presence of a large number of chondroblasts adjacent to the inner membrane surface in the first stages, and osteoblasts and osteocytes were observed under them. The bone formation was appositional. The Cr-Co-Mo alloy provides a scaffold with an adequate microenvironment for vertical bone volume augmentation, and the physical dimensions and disposition of the membrane itself influence the new bone formation.

  19. Influence of Chromium-Cobalt-Molybdenum Alloy (ASTM F75 on Bone Ingrowth in an Experimental Animal Model

    Directory of Open Access Journals (Sweden)

    Jésica Zuchuat

    2017-12-01

    Full Text Available Cr-Co-Mo (ASTM F75 alloy has been used in the medical environment, but its use as a rigid barrier membrane for supporting bone augmentation therapies has not been extensively investigated. In the present study, Cr-Co-Mo membranes of different heights were placed in New Zealand white, male rabbit tibiae to assess the quality and volume of new bone formation, without the use of additional factors. Animals were euthanized at 20, 30, 40, and 60 days. Bone formation was observed in all of the cases, although the tibiae implanted with the standard membranes reached an augmentation of bone volume that agreed with the density values over the timecourse. In all cases, plasmatic exudate was found under the membrane and in contact with the new bone. Histological analysis indicated the presence of a large number of chondroblasts adjacent to the inner membrane surface in the first stages, and osteoblasts and osteocytes were observed under them. The bone formation was appositional. The Cr-Co-Mo alloy provides a scaffold with an adequate microenvironment for vertical bone volume augmentation, and the physical dimensions and disposition of the membrane itself influence the new bone formation.

  20. Primary activity standardization of {sup 57}Co by sum-peak method

    Energy Technology Data Exchange (ETDEWEB)

    Iwahara, A. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI)/Instituto de Radioprotecao e Dosimetria (IRD)/Comissao Nacional de Energia Nuclear - CNEN, Av. Salvador Allende, s/no. Recreio dos Bandeirantes - CEP 22780-160 Rio de Janeiro (Brazil)], E-mail: iwahara@ird.gov.br; Poledna, R.; Silva, C.J. da; Tauhata, L. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI)/Instituto de Radioprotecao e Dosimetria (IRD)/Comissao Nacional de Energia Nuclear - CNEN, Av. Salvador Allende, s/no. Recreio dos Bandeirantes - CEP 22780-160 Rio de Janeiro (Brazil)

    2009-10-15

    The sum-peak method was applied to standardize a {sup 57}Co solution within the framework of an international comparison organized by International Atomic Energy Agency, in 2008, aimed toward international traceability of activity measurements. A planar germanium detector was used with the sources placed on top of the detector for activity determination measurements. An analytical expression for accidental summing correction was derived and the effect of the germanium characteristic KX-ray escape peak of 112 keV was taken into account. The standard uncertainty associated to the activity concentration value was 0.37% and the result was compared with other measurement methods.

  1. Assessment of wrought ASTM F1058 cobalt alloy properties for permanent surgical implants.

    Science.gov (United States)

    Clerc, C O; Jedwab, M R; Mayer, D W; Thompson, P J; Stinson, J S

    1997-01-01

    The behavior of the ASTM F1058 wrought cobalt-chromium-nickel-molybdenum-iron alloy (commonly referred to as Elgiloy or Phynox) is evaluated in terms of mechanical properties, magnetic resonance imaging, corrosion resistance, and biocompatibility. The data found in the literature, the experimental corrosion and biocompatibility results presented in this article, and its long track record as an implant material demonstrate that the cobalt superalloy is an appropriate material for permanent surgical implants that require high yield strength and fatigue resistance combined with high elastic modulus, and that it can be safely imaged with magnetic resonance.

  2. Glove powder's carrying capacity for latex protein: analysis using the ASTM ELISA test.

    Science.gov (United States)

    Beezhold, D; Horton, K; Hickey, V; Daddona, J; Kostyal, D

    2003-01-01

    Glove donning powders carry latex proteins and disperse them into the workplace environment. We have used the ASTM D6499 ELISA to quantify the amount of latex antigen bound to and carried by glove powders. We could differentiate between a small amount of protein actually bound to the powders and a larger amount carried by the powder. Enhanced binding of a major allergen, Hev b 5, to the starch powders was demonstrated by Western blot. The D6499 ELISA is able to measure total latex antigen, soluble and powder bound, simultaneously without the need to centrifuge the samples.

  3. Application of ASTM E-1559 Apparatus to Study H2O Desorption

    Science.gov (United States)

    Woronowicz, Michael; Perry, Radford, III; Meadows, George A.

    2015-01-01

    The NASA James Webb Space Telescope project identified a need to measure water vapor desorption from cryogenic surfaces in order to validate predictions of spacecraft design performance. A review of available scientific literature indicated no such measurements had been reported below 131 K. Contamination control personnel at NASA Goddard Space Flight Center recognized the possibility they readily possessed the means to collect these measurements at lower temperatures using an existing apparatus commonly employed for making outgassing observations. This presentation will relate how the ASTM E-1559 Molekit apparatus was used without physical modification to measure water vapor sublimation down to 120 K and compare this data to existing equilibrium vapor pressure models.

  4. Mechanical behaviour of Astm A 297 grade Hp joints welded using different processes

    International Nuclear Information System (INIS)

    Emygdio, Paulo Roberto Oliveira; Zeemann, Annelise; Almeida, Luiz Henrique de

    1996-01-01

    The influence of different arc welding processes on mechanical behaviour was studied for cast heat resistant stainless steel welded joints, in the as welded conditions. ASTM A 297 grade HP with niobium and niobium/titanium additions were welded following three different welding procedures, using shielded metal arc welding gas tungsten arc welding and plasma arc welding, in six welded joints. The welded joint mechanical behaviour was evaluated by ambient temperature and 870 deg C tensile tests; and creep tests at 900 deg C and 50 MPa. Mechanical test results showed that the welding procedure qualification following welding codes is not suitable for high temperature service applications. (author)

  5. Secondary standards (non-activation) for neutron data measurements above 20 MeV

    International Nuclear Information System (INIS)

    Haight, R.C.

    1991-01-01

    In addition to H(n,p) scattering and 235,238 U(n,f) reactions, secondary standards for neutron flux determination may be useful for neutron energies above 20 MeV. For experiments where gamma rays are detected, reference gamma-ray production cross sections are relevant. For neutron-induced charged particle production, standard (n,p) and (n,alpha) cross sections would be helpful. Total cross section standards would serve to check the accuracy of these measurements. These secondary standards are desirable because they can be used with the same detector systems employed in measuring the quantities of interest. Uncertainties due to detector efficiency, geometrical effects, timing and length of flight paths can therefore be significantly reduced. Several secondary standards that do not depend on activation techniques are proposed. 14 refs

  6. Initial testing of a neutron activation analysis system by analysing standard reference materials

    International Nuclear Information System (INIS)

    Suhaimi Hamzah; Roslan Idris; Abdul Khalik Haji Wood; Che Seman Mahmood; Abdul Rahim Mohamad Noor.

    1983-01-01

    This paper describes the data acquisition and processing system in our laboratories (ND6600), the methods of activation analysis and the results obtained from our analysis of IAEA standard reference material (SL-l lake sediments and NBS coal ash 1632a). These standards were analysed in order to check the capability of the system, which was designed in such a way as to enable the user to independently collect and process data from multiple radiation detectors. (author)

  7. Standard Practice for Dosimetry of Proton Beams for use in Radiation Effects Testing of Electronics

    International Nuclear Information System (INIS)

    McMahan, Margaret A.; Blackmore, Ewart; Cascio, Ethan W.; Castaneda, Carlos; von Przewoski, Barbara; Eisen, Harvey

    2008-01-01

    Representatives of facilities that routinely deliver protons for radiation effect testing are collaborating to establish a set of standard best practices for proton dosimetry. These best practices will be submitted to the ASTM International for adoption

  8. Standard Practice for Dosimetry of Proton Beams for use in Radiation Effects Testing of Electronics

    Energy Technology Data Exchange (ETDEWEB)

    McMahan, Margaret A.; Blackmore, Ewart; Cascio, Ethan W.; Castaneda, Carlos; von Przewoski, Barbara; Eisen, Harvey

    2008-07-25

    Representatives of facilities that routinely deliver protons for radiation effect testing are collaborating to establish a set of standard best practices for proton dosimetry. These best practices will be submitted to the ASTM International for adoption.

  9. What expects of academies. Activity of code and standard Div. in JSME, AESJ and JEA

    International Nuclear Information System (INIS)

    Miyano, Hiroshi

    2005-01-01

    The present states of establishment activities of standards by the three academies in the title are summarized from the viewpoint of 'explanation accountability'. Their roles and directions to go forward are also summarized. To be concrete, the trends of these establishment academies of standards relating to the nuclear industry are summarized. By focusing on the three indispensable conditions (neutrality, impartiality and transparency) for the establishment academy of standards and their implementation, the verifications of these conditions and 'explanation accountability' in these three academies are described. (K. Kato)

  10. Development of a Primary Standard for Calibration of [18F]FDG Activity Measurement Systems

    International Nuclear Information System (INIS)

    Capogni, M; Felice, P De; Fazio, A; Simonelli, F; Abbas, K

    2006-01-01

    The 18 F national primary standard was developed by the INMRI-ENEA using the 4πβ Liquid Scintillation Spectrometry Method with 3 H-Standard Efficiency Tracing. Measurements were performed at JRCIspra under a scientific collaboration between the Institute for Health and Consumer Production, the Amersham Health and the National Institute for Occupational Safety and Prevention (ISPESL). The goal of the work was to calibrate, with minimum uncertainty, the INMRI-ENEA transfer standard portable well-type ionisation chamber as well as other JRC-Ispra and Amersham Health reference Ionising Chambers used for FDG activity measurement

  11. Rare earths analysis of rock samples by instrumental neutron activation analysis, internal standard method

    International Nuclear Information System (INIS)

    Silachyov, I.

    2016-01-01

    The application of instrumental neutron activation analysis for the determination of long-lived rare earth elements (REE) in rock samples is considered in this work. Two different methods are statistically compared: the well established external standard method carried out using standard reference materials, and the internal standard method (ISM), using Fe, determined through X-ray fluorescence analysis, as an element-comparator. The ISM proved to be the more precise method for a wide range of REE contents and can be recommended for routine practice. (author)

  12. Development of a Primary Standard for Calibration of [{sup 18}F]FDG Activity Measurement Systems

    Energy Technology Data Exchange (ETDEWEB)

    Capogni, M [ENEA Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti (INMRI), Centro Ricerche Casaccia, I-00060 Rome (Italy); Felice, P De [ENEA Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti (INMRI), Centro Ricerche Casaccia, I-00060 Rome (Italy); Fazio, A [ENEA Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti (INMRI), Centro Ricerche Casaccia, I-00060 Rome (Italy); Simonelli, F [Institute for Health and Consumer Protection, Joint Research Centre (JRC), European Commission, I-21020 Ispra (Vatican City State, Holy See,), Italy; D' Ursi, V [Amersham Health Srl (AH), I-13040 Saluggia (Saint Vincent and the Grenadines), Italy; Pecorale, A [Amersham Health Srl (AH), I-13040 Saluggia (Saint Vincent and the Grenadines), Italy; Giliberti, C [Istituto Superiore per la Prevenzione e la Sicurezza del Lavoro (ISPESL), I-00184 Rome (Italy); Abbas, K [Institute for Health and Consumer Protection, Joint Research Centre (JRC), European Commission, I-21020 Ispra (Vatican City State, Holy See,), Italy

    2006-05-15

    The {sup 18}F national primary standard was developed by the INMRI-ENEA using the 4{pi}{beta} Liquid Scintillation Spectrometry Method with {sup 3}H-Standard Efficiency Tracing. Measurements were performed at JRCIspra under a scientific collaboration between the Institute for Health and Consumer Production, the Amersham Health and the National Institute for Occupational Safety and Prevention (ISPESL). The goal of the work was to calibrate, with minimum uncertainty, the INMRI-ENEA transfer standard portable well-type ionisation chamber as well as other JRC-Ispra and Amersham Health reference Ionising Chambers used for FDG activity measurement.

  13. A generic standard for assessing and managing activities with significant risk to health and safety

    International Nuclear Information System (INIS)

    Wilde, T.S.; Sandquist, G.M.

    2005-01-01

    Some operations and activities in industry, business, and government can present an unacceptable risk to health and safety if not performed according to established safety practices and documented procedures. The nuclear industry has extensive experience and commitment to assessing and controlling such risks. This paper provides a generic standard based upon DOE Standard DOE-STD-3007- 93, Nov 1993, Change Notice No. 1, Sep 1998. This generic standard can be used to assess practices and procedures employed by any industrial and government entity to ensure that an acceptable level of safety and control prevail for such operations. When any activity and operation is determined to involve significant risk to health and safety to workers or the public, the organization should adopt and establish an appropriate standard and methodology to ensure that adequate health and safety prevail. This paper uses DOE experience and standards to address activities with recognized potential for impact upon health and safety. Existing and future assessments of health and safety issues can be compared and evaluated against this generic standard for insuring that proper planning, analysis, review, and approval have been made. (authors)

  14. Development of healthy eating and physical activity quality standards for out-of-school time programs.

    Science.gov (United States)

    Wiecha, Jean L; Hall, Georgia; Gannett, Ellen; Roth, Barbara

    2012-12-01

    Out-of-school time (OST) programs serve over 8 million children per year and have ample opportunity to promote health through menu and physical activity choices. Until recently, however, the field has lacked a comprehensive set of operationalizable standards for healthy eating and physical activity. The National AfterSchool Association adopted voluntary healthy eating and physical activity quality standards (HEPAQS) in April, 2011. We describe the development of HEPAQS. This work reflects a social ecological model for changing children's eating and activity behaviors through program-level interventions. The standards were developed using a national, mixed-methods needs assessment, review of existing standards and expert recommendations, and a participatory process of discussion, review, and consensus engaging 19 influential service and policy organizations and agencies in the Healthy Out-of-School Time (HOST) coalition, which we convened in 2009. The HOST coalition approved a final version of the HEPAQS in January, 2011. The 11 standards address content, curriculum selection, staff training, program support, and environmental support for healthy eating and physical activity. In April, 2011, the HEPAQS were adopted by the National AfterSchool Association, and have subsequently been widely disseminated. Extensive adoption and implementation efforts are underway. The availability of a comprehensive set of standards for healthy eating and physical activity in OST provides practical information to help community-based youth-serving organizations participate in obesity and chronic disease prevention. A working awareness of their content will be useful to scientists undertaking health promotion studies in the out-of-school time setting.

  15. Application of MCDM based hybrid optimization tool during turning of ASTM A588

    Directory of Open Access Journals (Sweden)

    Himadri Majumder

    2017-07-01

    Full Text Available Multi-criteria decision making approach is one of the most troublesome tools for solving the tangled optimization problems in the machining area due to its capability of solving the complex optimization problems in the production process. Turning is widely used in the manufacturing processes as it offers enormous advantages like good quality product, customer satisfaction, economical and relatively easy to apply. A contemporary approach, MOORA coupled with PCA, was used to ascertain an optimal combination of input parameters (spindle speed, depth of cut and feed rate for the given output parameters (power consumption, average surface roughness and frequency of tool vibration using L27 orthogonal array for turning on ASTM A588 mild steel. Comparison between MOORA-PCA and TOPSIS-PCA shows the effectiveness of MOORA over TOPSIS method. The optimum parameter combination for multi-performance characteristics has been established for ASTM A588 mild steel are spindle speed 160 rpm, depth of cut 0.1 mm and feed rate 0.08 mm/rev. Therefore, this study focuses on the application of the hybrid MCDM approach as a vital selection making tool to deal with multi objective optimization problems.

  16. ASTM clustering for improving coal analysis by near-infrared spectroscopy.

    Science.gov (United States)

    Andrés, J M; Bona, M T

    2006-11-15

    Multivariate analysis techniques have been applied to near-infrared (NIR) spectra coals to investigate the relationship between nine coal properties (moisture (%), ash (%), volatile matter (%), fixed carbon (%), heating value (kcal/kg), carbon (%), hydrogen (%), nitrogen (%) and sulphur (%)) and the corresponding predictor variables. In this work, a whole set of coal samples was grouped into six more homogeneous clusters following the ASTM reference method for classification prior to the application of calibration methods to each coal set. The results obtained showed a considerable improvement of the error determination compared with the calibration for the whole sample set. For some groups, the established calibrations approached the quality required by the ASTM/ISO norms for laboratory analysis. To predict property values for a new coal sample it is necessary the assignation of that sample to its respective group. Thus, the discrimination and classification ability of coal samples by Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS) in the NIR range was also studied by applying Soft Independent Modelling of Class Analogy (SIMCA) and Linear Discriminant Analysis (LDA) techniques. Modelling of the groups by SIMCA led to overlapping models that cannot discriminate for unique classification. On the other hand, the application of Linear Discriminant Analysis improved the classification of the samples but not enough to be satisfactory for every group considered.

  17. Weldability examination of ASTM A 240 S41500 martensitic stainless steel by thermal cycles simulation testings

    Directory of Open Access Journals (Sweden)

    Alberto Velázquez-del Rosario

    2015-07-01

    Full Text Available The weldability assets of ASTM A 240 S41500 (ASTM A 240/A 240M martensitic stainless steel are presented through the study of the effects of single and double thermal weld cycles on mechanical properties and microstructure of base metal (BM and the artificial heat affected zone (HAZ created by thermal weld simulations. For single cycles, separate peak temperatures of 1000 ºC/12 s and 1350 ºC/12 s (cooling times: 12 s in both cases were evaluated, whilst two combinations of peak temperatures: (1350 ºC/5 s + 1000 ºC/5 s ºC and (1350 ºC/12 s + 1000 ºC/12 s ºC (cooling times: 5 s and 12 s, were applied for double cycles. Post weld heat treatment (PWHT with short and long holding times were applied and Vickers hardness, impact toughness and metallographic examinations were used in order to assess mechanical and metallographic properties in the as-simulated (no heat treated and postweld heat treated conditions. Best properties of the welded joint for double thermal weld cycles with long holding times were reached, which reveals the good weldability and applicability of the tested material in post weld heat treated conditions.

  18. Methods for preparing comparative standards and field samples for neutron activation analysis of soil

    International Nuclear Information System (INIS)

    Glasgow, D.C.; Dyer, F.F.; Robinson, L.

    1994-01-01

    One of the more difficult problems associated with comparative neutron activation analysis (CNAA) is the preparation of standards which are tailor-made to the desired irradiation and counting conditions. Frequently, there simply is not a suitable standard available commercially, or the resulting gamma spectrum is convoluted with interferences. In a recent soil analysis project, the need arose for standards which contained about 35 elements. In response, a computer spreadsheet was developed to calculate the appropriate amount of each element so that the resulting gamma spectrum is relatively free of interferences. Incorporated in the program are options for calculating all of the irradiation and counting parameters including activity produced, necessary flux/bombardment time, counting time, and appropriate source-to-detector distance. The result is multi-element standards for CNAA which have optimal concentrations. The program retains ease of use without sacrificing capability. In addition to optimized standard production, a novel soil homogenization technique was developed which is a low cost, highly efficient alternative to commercially available homogenization systems. Comparative neutron activation analysis for large scale projects has been made easier through these advancements. This paper contains details of the design and function of the NAA spreadsheet and innovative sample handling techniques

  19. Methods for preparing comparative standards and field samples for neutron activation analysis of soil

    International Nuclear Information System (INIS)

    Glasgow, D.C.; Dyer, F.F.; Robinson, L.

    1995-01-01

    One of the more difficult problems associated with comparative neutron activation analysis (CNAA) is the preparation of standards which are tailor-made to the desired irradiation and counting conditions. Frequently, there simply is not a suitable standard available commercially, or the resulting gamma spectrum is convoluted with interferences. In a recent soil analysis project, the need arose for standards which contained about 35 elements. In response, a computer spreadsheet was developed to calculate the appropriate amount of each element so that the resulting gamma spectrum is relatively free of interferences. Incorporated in the program are options for calculating all of the irradiation and counting parameters including activity produced, necessary flux/bombardment time, counting time, and appropriate source-to-detector distance. The result is multi-element standards for CNAA which have optimal concentrations. The program retains ease of use without sacrificing capability. In addition to optimized standard production, a novel soil homogenization technique was developed which is a low cost, highly efficient alternative to commercially available homogenization systems. Comparative neutron activation analysis for large scale projects has been made easier through these advancements. This paper contains details of the design and function of the NAA spreadsheet and innovative sample handling techniques. (author) 7 refs.; 5 tabs

  20. Standardization of the Manufacturing Process of Bee Venom Pharmacopuncture Containing Melittin as the Active Ingredient

    OpenAIRE

    Yoonmi Lee; Sung-Geun Kim; In-Su Kim; Hwa-Dong Lee

    2018-01-01

    Background. Pharmacopuncture is a unique treatment in oriental medicine that combines chemical stimulation with conventional acupuncture. However, there are no standardized methods for preparing the herbal medicines used in pharmacopuncture, and it is not clear whether the active ingredients are safe and stable. Several studies have investigated nonstandardized preparation processes, but few investigations have addressed safety and preparation methods. Pharmacopuncture may provide an alternat...

  1. Validity of consumer-grade activity monitor to identify manual wheelchair propulsion in standardized activities of daily living.

    Science.gov (United States)

    Leving, Marika T; Horemans, Henricus L D; Vegter, Riemer J K; de Groot, Sonja; Bussmann, Johannes B J; van der Woude, Lucas H V

    2018-01-01

    Hypoactive lifestyle contributes to the development of secondary complications and lower quality of life in wheelchair users. There is a need for objective and user-friendly physical activity monitors for wheelchair-dependent individuals in order to increase physical activity through self-monitoring, goal setting, and feedback provision. To determine the validity of Activ8 Activity Monitors to 1) distinguish two classes of activities: independent wheelchair propulsion from other non-propulsive wheelchair-related activities 2) distinguish five wheelchair-related classes of activities differing by the movement intensity level: sitting in a wheelchair (hands may be moving but wheelchair remains stationary), maneuvering, and normal, high speed or assisted wheelchair propulsion. Sixteen able-bodied individuals performed sixteen various standardized 60s-activities of daily living. Each participant was equipped with a set of two Activ8 Professional Activity Monitors, one at the right forearm and one at the right wheel. Task classification by the Active8 Monitors was validated using video recordings. For the overall agreement, sensitivity and positive predictive value, outcomes above 90% are considered excellent, between 70 and 90% good, and below 70% unsatisfactory. Division in two classes resulted in overall agreement of 82.1%, sensitivity of 77.7% and positive predictive value of 78.2%. 84.5% of total duration of all tasks was classified identically by Activ8 and based on the video material. Division in five classes resulted in overall agreement of 56.6%, sensitivity of 52.8% and positive predictive value of 51.9%. 59.8% of total duration of all tasks was classified identically by Activ8 and based on the video material. Activ8 system proved to be suitable for distinguishing between active wheelchair propulsion and other non-propulsive wheelchair-related activities. The ability of the current system and algorithms to distinguish five various wheelchair-related activities

  2. Work related perceived stress and muscle activity during standardized computer work among female computer users

    DEFF Research Database (Denmark)

    Larsman, P; Thorn, S; Søgaard, K

    2009-01-01

    The current study investigated the associations between work-related perceived stress and surface electromyographic (sEMG) parameters (muscle activity and muscle rest) during standardized simulated computer work (typing, editing, precision, and Stroop tasks). It was part of the European case......-control study, NEW (Neuromuscular assessment in the Elderly Worker). The present cross-sectional study was based on a questionnaire survey and sEMG measurements among Danish and Swedish female computer users aged 45 or older (n=49). The results show associations between work-related perceived stress...... and trapezius muscle activity and rest during standardized simulated computer work, and provide partial empirical support for the hypothesized pathway of stress induced muscle activity in the association between an adverse psychosocial work environment and musculoskeletal symptoms in the neck and shoulder....

  3. Validation of the k0 standardization method in neutron activation analysis

    International Nuclear Information System (INIS)

    Kubesova, Marie

    2009-01-01

    The goal of this work was to validate the k 0 standardization method in neutron activation analysis for use by the Nuclear Physics Institute's NAA Laboratory. The precision and accuracy of the method were examined by using two types of reference materials: the one type comprised a set of synthetic materials and served to check the implementation of k 0 standardization, the other type consisted of matrix NIST SRMs comprising various different matrices. In general, a good agreement was obtained between the results of this work and the certified values, giving evidence of the accuracy of our results. In addition, the limits were evaluated for 61 elements

  4. Hardness optimization of boride diffusion layer on Astm F-75 alloy using response surface methodology

    Energy Technology Data Exchange (ETDEWEB)

    Arguelles O, J. L.; Corona R, M. A. [Universidad Autonoma de San Luis Potosi, Doctorado Institucional en Ingenieria y Ciencia de Materiales, San Luis Potosi 78000, SLP (Mexico); Marquez H, A.; Saldana R, A. L.; Saldana R, A. [Universidad de Guanajuato, Ingenieria Mecanica Agricola DICIVA, Irapuato, Guanajuato 36500 (Mexico); Moreno P, J., E-mail: amarquez@ugto.mx [Universidad de Guanajuato, Departamento de Minas, Metalurgia y Geologia, Ex-Hacienda San Matias s/n, Guanajuato, Guanajuato 36020 (Mexico)

    2017-11-01

    In this study, the Response Surface Methodology (Rsm) and Central Composite Design (Ccd) were used to optimize the hardness of boride diffusion layer on Astm F-75 alloy (also called Haynes alloy). A boronizing thermochemical treatment was carried out at different temperatures and for different time periods. Hardness tests were conducted. The boride diffusion layer was verified by the X-ray diffraction (XRD) analysis indicating the formation of Co B, Co{sub 2}B, Cr B and Mo{sub 2}B phases. An optimal hardness of 3139.7 Hv was obtained for the samples subjected to the boriding process for a duration of 6.86 h at 802.4 degrees Celsius. (Author)

  5. Determination of CTOD C in Fibre Metal Laminates by ASTM and Schwalbe Methods

    Directory of Open Access Journals (Sweden)

    E.M. Castrodeza

    2002-06-01

    Full Text Available Fibre Metal Laminates (FMLs have arisen as a demand of the aeronautical industry to use thin sheets with high resistance to fatigue crack growth, high damage tolerance, corrosion resistance and high specific strength. Considering these requirements, FMLs are an advantageous choice when compared to metal alloys currently used. In order to employ FMLs in aircraft structures, designers must hold a deep knowledge of a wide set of their properties including fracture toughness. The aim of this work was to evaluate the available methodologies to measure fracture toughness at instability (CTOD C in unidirectional fibre metal laminates reinforced with aramid fibres (ARALL®. To achieve this, tests were performed to obtain traditional and Schwalbe CTODs by using experimental ASTM based techniques, especially adapted to these laminates. Results achieved point out that Schwalbe method is more appropriate and also that there are differences between both CTOD parameters.

  6. Heat treatment evaluation of steel ASTM A-131 grade A by X-Ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira Junior, Francisco; Feio, Luciana Gaspar; Costa, Ednelson Silva; Rodrigues, Lino Alberto Soares; Braga, Eduardo Magalhaes, E-mail: juniorferrer93@gmail.com [Universidade Federal do Pará (UFPA), Belém, PA (Brazil)

    2016-07-01

    Full text: This study evaluates the residual stress of naval steel ASTM A-131 grade A before and after heat treatment. Residual stresses were determined by the technique of X-ray diffraction (XRD). Before heat treatment the residual stress measurements were made at 36 (thirty six) points distributed in a specimen with dimensions of 400 mm long, 200 mm wide and 95 mm thick, then the plate under analysis was brought to the oven for the implementation of heat treatment. To check the performance of the heat treatment, the plate was again subjected to XRD measurements of the same points previously measured in order to compare the residual stresses. As result, there was a reduction of residual stresses with the application of heat treatment. References: [1] COLPAERT, H. Metalografia dos Produtos Siderurgicos Comuns. 4 Edição. Editora Blucher. Saõ Paulo, SP, 2008. [2] HILL, R. Princípios de Metalurgia Física, 1992. (author)

  7. Designing cathodic protection systems for marine structures and vehicles. ASTM special technical publication 1370

    Energy Technology Data Exchange (ETDEWEB)

    Hack, H.P. [ed.

    1999-07-01

    Cathodic protection is an important method of protecting structures and ships from the corrosive effects of seawater. Poor designs can be far more costly to implement than optimal designs, Improper design can cause overprotection, with resulting paint blistering and accelerated corrosion of some alloys, underprotection, with resultant structure corrosion, or stray current corrosion of nearby structures. The first ASTM symposium specifically aimed at cathodic protection in seawater was intended to compile all the criteria and philosophy for designing both sacrificial and impressed current cathodic protection systems for structures and vehicles in seawater. The papers which are included in this STP are significant in that they summarize the major seawater cathodic protection system design philosophies. Papers have been processed separately for inclusion on the database.

  8. Phases Evolution of an ASTM 335 steel under continuous cooling P91

    International Nuclear Information System (INIS)

    Carrizo, D.A; Danon, C.A; Ramos, C.P

    2012-01-01

    This paper studies the influence of the cooling rate on phase transformations and the resulting microstructure in continuous cooling cycles for an ASTM A335 P91 steel, under fixed austenization conditions. The CCT (Continuous Cooling Transformation) diagram of this material is reported in the literature, so the main phase fields are known. The final structure of the samples depends on the austenitic grain size and the cooling rate. The studied samples were austenized at 1050 o C for 30 minutes and then cooled at different rates between 50 o C/h and 300 o C/h. The identification and characterization of the phases was carried out by using Scanning Electron Microscopy, X-ray Diffraction and Moessbauer Spectroscopy. From the results so obtained, additions to the CCT diagram of the material are proposed, providing new information to it

  9. Corrosion resistant properties and weldabilities of ASTM Grade 12 titanium alloy

    International Nuclear Information System (INIS)

    Tsumori, Yoshikatsu; Itoh, Hideo

    1988-01-01

    Plates, sheets, bars, wires and thinner seam-welded tubings were manufactured from large-scaled ingot of ASTM Grade 12 alloy (Ti-0.8Ni-0.3Mo). The processability of G-12 alloy has proved almost similar to that of conventional commercially pure titanium grades. It has been clarified that the G-12 alloy showed several advantageous features: Chlorides-Crevice corrosion resistance of the alloy was almost equals to G-7 and Pd0/TiO 2 coated titanium, and the maximum allowable stress was able to be designed higher than that of commercially pure titanium. This alloy has been in applications also offers where such environments as seawater, brines and moist chlorine, various oil refinery and chemical industries, and others. (author)

  10. Effects of heat treatment to the sound velocity and microstructural changes of ASTM A516 steels

    International Nuclear Information System (INIS)

    Norasiah Abdul Kasim; Azali Muhammad; Amry Amin Abas; Zaiton Selamat

    2010-01-01

    Full-text: The used of ultrasonic testing as a thickness measurement for structural components (pipeline and pressure vessel) is among the popular inspection tool widely use in the industrial power plant such as at petrochemical and nuclear power plant. Currently, there are cases where the thickness grows and the result will affect the reliability of the test. There are many factors that can affect the reliability of measurement. One of it is the material under test itself. In the Malaysian Nuclear Agency, initial efforts are underway to study the understanding on the effects of heat treatment to the sound velocity and microstructure changes of ASTM A516 steel. Few samples of thin square shaped prepared were heat treated under the following conditions: austenitization at 9800 degree Celsius - 2 hours, quenching; tempering at various temperature 4000, 5000, 6000 and 7000 degree Celsius. The results show that the microstructure changes and samples exhibit different sound velocity at different heat treatment. (author)

  11. Microstructure evolution of ASTM 335 P91 steel, subjected to continuous cooling

    International Nuclear Information System (INIS)

    Carrizo, D.A; Danon, C.A; Ramos, C.P

    2012-01-01

    This paper studies the influence of the cooling rate on an isothermal phase transformations in ASTM A335 P91 steel, by the analysis of the resulting microstructure after several continuous cooling cycles under fixed austenization conditions. The CCT (Continuous Cooling Transformation) diagram of this material has already been reported in the literature, so the main phase fields are known, and they depend on the austenitic grain size and the cooling rate. Five samples were tested in a dilatometer, they were austenized and then cooled at different rates between 50 o C/h and 300 o C/h. The identification and characterization of the resulting phases was carried out by using Scanning Electron Microscopy, X-ray Diffraction and Mossbauer Spectroscopy. The obtained results allowed to add information about the presence of retained austenite and (Fe,Cr) 3 C - type carbides to the CCT diagram of the material (author)

  12. Risk assessment of manual material handling activities (case study: PT BRS Standard Industry)

    Science.gov (United States)

    Deviani; Triyanti, V.

    2017-12-01

    The process of moving material manually has the potential for injury to workers. The risk of injury will increase if we do not pay attention to the working conditions. The purpose of this study is to assess and analyze the injury risk level in manual handling material activity, as well as to improve the condition. The observed manual material handling activities is pole lifting and goods loading. These activities were analyzed using Job Strain Index method, Rapid Entire Body Assessment, and Chaffin’s 2D Planar Static Model. The results show that most workers who perform almost all activities have a high level of risk level with the score of JSI and REBA exceeds 9 points. For some activities, the estimated compression forces in the lumbar area also exceed the standard limits of 3400 N. Concerning this condition, several suggestions for improvement were made, improving the composition of packing, improving body posture, and making guideline posters.

  13. Determination of ASTM 1016 structural welded joints fracture toughness through J integral

    International Nuclear Information System (INIS)

    Martins, Geraldo de Paula; Villela, Jefferson Jose; Terra, Jose Lucio; Rabello, Emerson Giovani; Martins, Geraldo Antonio Scoralick; Carneiro, Jose Rubens Goncalves

    2009-01-01

    Fracture toughness is an important parameter for studies of materials behavior in nuclear and conventional industry. Crack propagation resistance is, in general, evaluate using one of the fracture mechanics parameters K IC , for the case of the materials that exhibits a linear elastic behavior, the CTOD (crack tip opening displacement) and J IC , the critical value of J Integral, for the case of materials with elastic-plastic behavior. On this work the fracture mechanics parameters of the ASTM 1016 structural steel welded joints were obtained, using the J Integral. Charpy V tests at several temperatures were also obtained, with the purpose to obtain the curves of ductile-brittle of the regions of the welded joints: Base Metal, (MB), and Melted Zone (MZ). The joints were welded by Gas Metal Arc Welding (GMAW) with V bevel for evaluation the MZ toughness properties. The tests were accomplished at temperatures varying from -100 deg C to 100 deg C using the technical of compliance variation for J IC determination, the critical value that defines the initial stable crack growth, that applies to brittle and ductile materials. The J Integral alternative specimens has square cross section 10mmX10mm, according ASTM E 1820, with notch localized respectively at the BM and MZ. After the tests, the specimens fractured were analyzed in a scanning microscopic electronic (SME) for verification of the fracture surface. The fractography of the specimens at elevated temperatures presented dimples at the region of stable crack growth, characteristic of ductile fracture. The results of J Integral and Charpy V presented a good correlation between these two parameters. From these correlations it can be concluded that in some applications, the use Charpy V energy to infer fracture toughness can be substitute the Integral J tests. (author)

  14. From policy to practice: strategies to meet physical activity standards in YMCA afterschool programs.

    Science.gov (United States)

    Beets, Michael W; Weaver, Robert G; Moore, Justin B; Turner-McGrievy, Gabriel; Pate, Russell R; Webster, Collin; Beighle, Aaron

    2014-03-01

    In 2011, the U.S. Young Men's Christian Association (YMCA) adopted activity standards recommending that afterschool programs (ASPs) ensure all children engage in a minimum of 30 minutes of moderate to vigorous physical activity (MVPA) daily during the ASP. ASPs decide how to accomplish this standard, for which few effective strategies exist. To evaluate strategies designed to help ASPs meet the MVPA standard. Single group intervention with pretest and three follow-up measures repeated-cross-sectional design with a subsample cohort. Four large-scale YMCA ASPs, serving approximately 500 children each day. Community-based participatory development of strategies focused on modification of program schedules, professional development training, and weekly checklists to evaluate activity opportunities. Accelerometry-derived MVPA classified as meet or fail-to-meet the 30 minutes' MVPA/day standard collected over a minimum of 4 nonconsecutive days at baseline (fall 2011) and three follow-up assessments (spring 2012, fall 2012, spring 2013). Random intercept logistic regression models evaluated the probability of meeting the standard for boys and girls, separately (analyzed summer 2013). A total of 895 children (aged 5-12 years, 48.4% girls) representing 3654 daily measures were collected across the four assessments. The percentage of girls and boys meeting the MVPA standard at baseline was 13.3% and 28.0%, respectively. By spring 2013, this increased to 29.3% and 49.6%. These changes represented an increase in the odds of meeting the 30 minutes' MVPA/day standard by 1.5 (95% CI=1.1, 2.0) and 2.4 (95% CI=1.2, 4.8) for girls and boys, respectively. The strategies developed herein represent an effective approach to enhancing current practice within YMCA ASPs to achieve existing MVPA standards. Additional work is necessary to evaluate the scalability of the strategies in a larger sample of ASPs. © 2014 American Journal of Preventive Medicine Published by American Journal of

  15. Status report on activities of ASTM E10.05.01 Task Group on Uncertainty Analysis

    International Nuclear Information System (INIS)

    Kam, F.B.K.; Stallman, F.W.

    1979-01-01

    Uncertainties in the field of reactor dosimetry are analyzed. A survey on uncertainty analysis as it is practiced at leading laboratories which are involved in reactor dosimetry is described. A questionnaire was prepared and mailed to about 45 installations and researchers. Nine replies were received, several of them were prepared by more than one author. Three of the nine came from installations outside the US. Results and the questionnaire are presented

  16. Comparison of exertion required to perform standard and active compression-decompression cardiopulmonary resuscitation.

    Science.gov (United States)

    Shultz, J J; Mianulli, M J; Gisch, T M; Coffeen, P R; Haidet, G C; Lurie, K G

    1995-02-01

    Active compression-decompression (ACD) cardiopulmonary resuscitation (CPR) utilizes a hand-held suction device with a pressure gauge that enables the operator to compress as well as actively decompress the chest. This new CPR method improves hemodynamic and ventilatory parameters when compared with standard CPR. ACD-CPR is easy to perform but may be more labor intensive. The purpose of this study was to quantify and compare the work required to perform ACD and standard CPR. Cardiopulmonary testing was performed on six basic cardiac life support- and ACD-trained St. Paul, MN fire-fighter personnel during performance of 10 min each of ACD and standard CPR on a mannequin equipped with a compression gauge. The order of CPR techniques was determined randomly with > 1 h between each study. Each CPR method was performed at 80 compressions/min (timed with a metronome), to a depth of 1.5-2 inches, and with a 50% duty cycle. Baseline cardiopulmonary measurements were similar at rest prior to performance of both CPR methods. During standard and ACD-CPR, respectively, rate-pressure product was 18.2 +/- 3.0 vs. 23.8 +/- 1.7 (x 1000, P CPR compared with standard CPR. Both methods require subanaerobic energy expenditure and can therefore be sustained for a sufficient length of time by most individuals to optimize resuscitation efforts. Due to the slightly higher work requirement, ACD-CPR may be more difficult to perform compared with standard CPR for long periods of time, particularly by individuals unaccustomed to the workload requirement of CPR, in general.

  17. Use of sum-peak and coincidence counting methods for activity standardization of {sup 22}Na

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, E.M. de, E-mail: estela@ird.gov.br [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Iwahara, A.; Poledna, R. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Silva, M.A.L. da [Coordenacao Geral de Instalacoes Nucleares/Comissao Nacional de Energia Nuclear, R. Gal. Severiano, 90 - Botafogo, CEP 22290-901 Rio de Janeiro (Brazil); Tauhata, L. [Fundacao Carlos Chagas Filho de Amparo a Pesquisa do Estado do Rio de Janeiro (FAPERJ), Av. Erasmo Braga, 118-6 Degree-Sign andar, CEP 20020-000 Centro, Rio de Janeiro (Brazil); Delgado, J.U. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Lopes, R.T. [Laboratorio de Instrumentacao Nuclear (LIN/PEN/COPPE/UFRJ), Caixa Postal 68509, CEP 21945-970 Rio de Janeiro (Brazil)

    2012-09-21

    A solution containing the positron emitter {sup 22}Na has been absolutely standardized using the 4{pi}{beta}-{gamma} coincidence counting method and the sum-peak spectrometry counting method. In the 4{pi}{beta}-{gamma} coincidence method two ways for the activity concentration measurements were used: gating on the 1275 keV photopeak and on the 1786 keV sum-peak where the knowledge of the {beta}{sup +}-branching ratio is required. In the sum-peak method the measurements were carried out using three experimental arrangements: the first composed by a well type 5 in. Multiplication-Sign 5 in. NaI(Tl) scintillation crystal, the second by a 3 in. Multiplication-Sign 3 in. NaI(Tl) scintillation crystal placed on the top of the first, resulting in a 4{pi} counting geometry and the third arrangement is a high purity coaxial germanium detector. The results that are obtained by these two methods are compatible within the standard uncertainty values with a coverage factor of k=2 ({approx}95% of the confidence level). This means that the sum-peak counting with its more simple experimental setup than the complex coincidence 4{pi}{beta}-{gamma} counting system gives consistent results for the activity standardization of {sup 22}Na with smaller uncertainties. Besides, the time period involved to attain the result of the standardization was quite shorter than the coincidence measurements used in this work.

  18. The k0-based neutron activation analysis: a mono standard to standardless approach of NAA

    International Nuclear Information System (INIS)

    Acharya, R.; Nair, A.G.C.; Sudarshan, K.; Goswami, A.; Reddy, A.V.R.

    2006-01-01

    The k 0 -based neutron activation analysis (k 0 -NAA) uses neutron flux parameters, detection efficiency and nuclear constants namely k 0 and Q 0 for the determination of concentration of elements. Gold ( 197 Au) or any other element having suitable nuclear properties is used as external or internal single comparator. This article describes the principle of k 0 -NAA and standardization of method by characterization of reactor irradiation sites and calibration of efficiency of the detector and applications. The method was validated using CRMs obtained from USGS, IAEA and NIST. The applications of method includes samples like gemstones (ruby, beryl and emerald), sediments, manganese nodules and encrustations, cereals, and medicinal and edible leaves. Recently, a k-o-based internal mono standard INAA (IM-NAA) method using in-situ relative efficiency has been standardized by us for the analysis of small and large samples of different shapes and sizes. The method was applied to a new meteorite sample and large size wheat samples. Non-standard size and shape samples of nuclear cladding materials namely zircaloy 2 and 4, stainless steels (SS 316M and D9) and 1S aluminium were analysed. Standard-less analysis of these cladding materials was possible by mass balance approach since all the major and minor elements were amenable to NAA. (author)

  19. Ketosteroid Standardized Cissus quadrangularis L. Extract and its Anabolic Activity: Time to Look Beyond Ketosteroid?

    Science.gov (United States)

    Jadhav, Atul N; Rafiq, Mohammed; Devanathan, Rajendran; Azeemuddin, Mohammed; Anturlikar, Suryakanth D; Ahmed, Akhil; Sundaram, Ramchandran; Babu, U V; Paramesh, Rangesh

    2016-05-01

    Cissus quadrangularis (CQ) L. reported to contain 3-ketosteroids and have bone health benefits. This study aimed at establishing the relationship between the ketosteroid content and anabolic as well as bone health-promoting activities of various Cissus extracts in well-established orchidectomized (ORX) rat model. Supercritical carbon dioxide, ethyl acetate, and aqueous extracts (AE) of CQ L. were prepared and standardized for ketosteroid content by two methods used in commerce. Moreover, ketosteroid standardized extracts of this plant were evaluated for anabolic activity in rats in well-established ORX rat model. The increase in the absolute weight was appreciable in the CQ-AE treated group. Similarly, with respect to bone parameters, a similar trend was seen. The mean bone density, strength, and calcium content were found to be highest in the group treated with CQ-AE compared to groups treated with other extracts. This study reveals for the first time that 3-ketosteroids are not linked to the beneficial activities on bone and highlights the need for extensive characterization of biological active principles from CQ L. In light of the above estimation studies, we believe that current standardization of Cissus extraction "3-ketosteroids" is incorrect. We also did not find any report suggesting the presence of androgenic steroids in this plant and hence the characterization based on "3-ketosteroids" is scientifically incorrect. This study highlights the insufficient understanding of biological active principles from CQ L. and underlines the need for extensive bioactivity guided studies. Cissus quadrangularis (CQ) L. reported to contain 3.ketosteroids and have bone health benefitsWe did not find correlation between ketosteroid content obtained by conventional methods and its biological effectStudies indicate that claims of ketosteroid content need not necessarily correlate to biological effects and hence warrants extensive phytochemical characterization of biological

  20. Calibration and consistency of results of an ionization-chamber secondary standard measuring system for activity

    International Nuclear Information System (INIS)

    Schrader, Heinrich

    2000-01-01

    Calibration in terms of activity of the ionization-chamber secondary standard measuring systems at the PTB is described. The measurement results of a Centronic IG12/A20, a Vinten ISOCAL IV and a radionuclide calibrator chamber for nuclear medicine applications are discussed, their energy-dependent efficiency curves established and the consistency checked using recently evaluated radionuclide decay data. Criteria for evaluating and transferring calibration factors (or efficiencies) are given

  1. Calibration of ARI QC ionisation chambers using the Australian secondary standards for activity

    International Nuclear Information System (INIS)

    Mo, L.; Van Der Gaast, H.A.; Alexiev, D.; Butcher, K.S.A.; Davies, J.

    1999-01-01

    The Secondary Standard Activity Laboratory (SSAL) in ANSTO routinely provides standardised radioactive sources, traceable activity measurements and custom source preparation services to customers. The most important activity carried out is the calibration of ionisation chambers located in the Quality Control (QC) section of Australian Radioisotopes (ARI). This ensures that their activity measurements are traceable to the Australian primary methods of standardisation. ARI QC ionisation chambers are calibrated for 99m Tc, 67 Ga, 131 I, 201 Tl and 153 Sm. The SSAL has a TPA ionisation chamber, which has been directly calibrated against a primary standard for a variety of radioactive nuclides. Calibration factors for this chamber were determined specifically for the actual volumes (5ml for 99m Tc, 131 I, 2ml for 67 Ga, 201 Tl and 3 ml for 153 Sm) and types of vial (Wheaton) which are routinely used at ARI. These calibration factors can be used to accurately measure the activity of samples prepared by ARI. The samples can subsequently be used to calibrate the QC ionisation chambers. QC ionisation chambers are re-calibrated biannually

  2. Effects of the normalizing time and temperature on the impact properties of ASTM A-516 grade 70 steel

    International Nuclear Information System (INIS)

    Carneiro, T.; Cescon, T.

    1982-01-01

    The influence of normalizing time and temperature, as well as the plate thickness, on the impact properties of ASTM A-516 grade 70 steel, is studied. Results show that different normalizing conditions may lead to equivalent microstructure with different impact properties. Normalizing conditions that cause low cooling rate in the critical zone exhibit banded microstructure with inferior impact properties. (Author) [pt

  3. 75 FR 70074 - Consensus Standards, Light-Sport Aircraft

    Science.gov (United States)

    2010-11-16

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Consensus Standards, Light-Sport... accepted consensus standards relating to the provisions of the Sport Pilot and Light-Sport Aircraft rule issued July 16, 2004, and effective September 1, 2004. ASTM International Committee F37 on Light Sport...

  4. 46 CFR 164.015-1 - Applicable specifications and standards.

    Science.gov (United States)

    2010-10-01

    ..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL MATERIALS Plastic Foam, Unicellular, Buoyant, Sheet... following specification and standard, of the issue in effect on the date the plastic foam material is...) ASTM D4986-98, Standard Test Method for Horizontal Burning Characteristics of Cellular Polymeric...

  5. Identifying Strategies Programs Adopt to Meet Healthy Eating and Physical Activity Standards in Afterschool Programs.

    Science.gov (United States)

    Weaver, Robert G; Moore, Justin B; Turner-McGrievy, Brie; Saunders, Ruth; Beighle, Aaron; Khan, M Mahmud; Chandler, Jessica; Brazendale, Keith; Randell, Allison; Webster, Collin; Beets, Michael W

    2017-08-01

    The YMCA of USA has adopted Healthy Eating and Physical Activity (HEPA) Standards for its afterschool programs (ASPs). Little is known about strategies YMCA ASPs are implementing to achieve Standards and these strategies' effectiveness. (1) Identify strategies implemented in YMCA ASPs and (2) evaluate the relationship between strategy implementation and meeting Standards. HEPA was measured via accelerometer (moderate-to-vigorous-physical-activity [MVPA]) and direct observation (snacks served) in 20 ASPs. Strategies were identified and mapped onto a capacity building framework ( Strategies To Enhance Practice [STEPs]). Mixed-effects regression estimated increases in HEPA outcomes as implementation increased. Model-implied estimates were calculated for high (i.e., highest implementation score achieved), moderate (median implementation score across programs), and low (lowest implementation score achieved) implementation for both HEPA separately. Programs implemented a variety of strategies identified in STEPs. For every 1-point increase in implementation score 1.45% (95% confidence interval = 0.33% to 2.55%, p ≤ .001) more girls accumulated 30 min/day of MVPA and fruits and/or vegetables were served on 0.11 more days (95% confidence interval = 0.11-0.45, p ≤ .01). Relationships between implementation and other HEPA outcomes did not reach statistical significance. Still regression estimates indicated that desserts are served on 1.94 fewer days (i.e., 0.40 vs. 2.34) in the highest implementing program than the lowest implementing program and water is served 0.73 more days (i.e., 2.37 vs. 1.64). Adopting HEPA Standards at the national level does not lead to changes in routine practice in all programs. Practical strategies that programs could adopt to more fully comply with the HEPA Standards are identified.

  6. Validation of five minimally obstructive methods to estimate physical activity energy expenditure in young adults in semi-standardized settings

    DEFF Research Database (Denmark)

    Schneller, Mikkel Bo; Pedersen, Mogens Theisen; Gupta, Nidhi

    2015-01-01

    We compared the accuracy of five objective methods, including two newly developed methods combining accelerometry and activity type recognition (Acti4), against indirect calorimetry, to estimate total energy expenditure (EE) of different activities in semi-standardized settings. Fourteen particip...

  7. SOFG: Standards requirements

    International Nuclear Information System (INIS)

    Gerganov, T.; Grigorov, S.; Kozhukharov, V.; Brashkova, N.

    2005-01-01

    It is well-known that Solid Oxide Fuel Cells will have industrial application in the nearest future. In this context, the problem of SOFC materials and SOFC systems standardization is of high level of priority. In the present study the attention is focused on the methods for physical and chemical characterization of the materials for SOFC components fabrication and about requirements on single SOFC cells tests. The status of the CEN, ISO, ASTM (ANSI, ASSN) and JIS class of standards has been verified. Standards regarding the test methods for physical-chemical characterization of vitreous materials (as sealing SOFC component), ceramic materials (as electrodes and electrolyte components, including alternative materials used) and metallic materials (interconnect components) are subject of overview. It is established that electrical, mechanical, surface and interfacial phenomena, chemical durability and thermal corrosion behaviour are the key areas for standardization of the materials for SOFC components

  8. Standardized phenology monitoring methods to track plant and animal activity for science and resource management applications

    Science.gov (United States)

    Denny, Ellen G.; Gerst, Katharine L.; Miller-Rushing, Abraham J.; Tierney, Geraldine L.; Crimmins, Theresa M.; Enquist, Carolyn A.F.; Guertin, Patricia; Rosemartin, Alyssa H.; Schwartz, Mark D.; Thomas, Kathryn A.; Weltzin, Jake F.

    2014-01-01

    Phenology offers critical insights into the responses of species to climate change; shifts in species’ phenologies can result in disruptions to the ecosystem processes and services upon which human livelihood depends. To better detect such shifts, scientists need long-term phenological records covering many taxa and across a broad geographic distribution. To date, phenological observation efforts across the USA have been geographically limited and have used different methods, making comparisons across sites and species difficult. To facilitate coordinated cross-site, cross-species, and geographically extensive phenological monitoring across the nation, the USA National Phenology Network has developed in situ monitoring protocols standardized across taxonomic groups and ecosystem types for terrestrial, freshwater, and marine plant and animal taxa. The protocols include elements that allow enhanced detection and description of phenological responses, including assessment of phenological “status”, or the ability to track presence–absence of a particular phenophase, as well as standards for documenting the degree to which phenological activity is expressed in terms of intensity or abundance. Data collected by this method can be integrated with historical phenology data sets, enabling the development of databases for spatial and temporal assessment of changes in status and trends of disparate organisms. To build a common, spatially, and temporally extensive multi-taxa phenological data set available for a variety of research and science applications, we encourage scientists, resources managers, and others conducting ecological monitoring or research to consider utilization of these standardized protocols for tracking the seasonal activity of plants and animals.

  9. Applicability of ISO 9001: 2000 standard to design and research activities in nuclear objectives and installations

    International Nuclear Information System (INIS)

    Stamatopol, M.; Patticu, C.

    2001-01-01

    The ISO 9001: 2000 standard contains the results of the latest studies concerning the design and implementation of quality management systems. The continuous improvement of these systems required a new approach, namely, the process-based approach. A process-based model of quality management is presented in terms of client request, input data, management responsibility, resource management, product realisation, measurement / analysis and optimization, product, output data and client request fulfilment. Thus, the quality management system becomes an ensemble of interconnected or interacting processes. Consequently, to implement such a system the necessary processes have to be identified and their ISO 9001: 2000 standard based management ensured. Process based approach also allows better evidencing the input and output data specific to each process. Such an approach grants a wider applicability to the design and research activities in nuclear objectives and installations. This work aims at identifying additional requirements implied in design and research activities in nuclear field, as stipulated in the following standards / documents: - IAEA SG Q8 'Quality assurance in research and development'; - IAEA SG Q10 'Quality assurance in design'; - CAN / CSA N 286.2 - 00 'Design Quality Assurance for Nuclear Power Plants'; CAN 3 - CSA Z 299.1 'Quality Assurance Program - Category 1'; - NQA - 1, SUPPLEMENT 3S-1 'Supplementary requirements for design control'

  10. Anti-inflammatory activity of standardized dichloromethane extract of Salvia connivens on macrophages stimulated by LPS.

    Science.gov (United States)

    González-Chávez, Marco Martín; Ramos-Velázquez, Cinthia Saraí; Serrano-Vega, Roberto; Pérez-González, Cuauhtemoc; Sánchez-Mendoza, Ernesto; Pérez-Gutiérrez, Salud

    2017-12-01

    A previous study demonstrated that the chloroform extract of Salvia connivens Epling (Lamiaceae) has anti-inflammatory activity. Identification of the active components in the dicholorometane extract (DESC), and, standardization of the extract based in ursolic acid. DESC was prepared by percolation with dichlromethane and after washed with hot hexane, its composition was determined by CG-MS and NMR, and standardized by HPLC. The anti-inflammatory activity was tested on acute TPA-induced mouse ear oedema at doses of 2.0 mg/ear. The cell viability of macrophages was evaluated by MTT method, and pro- and anti-inflammatory interleukin levels were measured using an ELISA kit. Ursolic acid, oleanolic acid, dihydroursolic acid and eupatorin were identified in DESC, which was standardized based on the ursolic acid concentration (126 mg/g). The anti-inflammatory activities of DESC, the acid mixture, and eupatorin (2 mg/ear) were 60.55, 57.20 and 56.40% inhibition, respectively, on TPA-induced ear oedema. The IC 50 of DESC on macrophages was 149.4 μg/mL. DESC (25 μg/mL) significantly reduced TNF-α (2.0-fold), IL-1β (2.2-fold) and IL-6 (2.0-fold) in macrophages stimulated with LPS and increased the production of IL-10 (1.9-fold). Inflammation is a basic response to injuries, and macrophages are involved in triggering inflammation. Macrophage cells exhibit a response to LPS, inducing inflammatory mediators, and DESC inhibits the biosynthesis of the pro-inflammatory and promote anti-inflammatory cytokines. DESC has an anti-inflammatory effect; reduced the levels of IL-1β, Il-6 and TNF-α; and increases IL-10 in macrophages stimulated with LPS. Ursolic acid is a good phytochemical marker.

  11. [Validity of a standard questionnaire to assess physical activity for specific medical checkups and health guidance].

    Science.gov (United States)

    Kawakami, Ryoko; Miyachi, Motohiko

    2010-10-01

    This study aimed to determine the validity of a standard questionnaire to assess amount of physical activity (PA) and cardiorespiratory fitness (VO2peak). A total of 483 men and women, aged 20 to 69 years, participated. The standard questionnaire included 3 items about exercise, PA, and walking speed. All questions were designed to require an answer of Yes or No. Subjects were classified into one of four groups regarding the number of Yes answers to the three questions, giving activity levels of 0 to 3. The amount of PA was measured objectively with a tn-axial accelerometer which could also calculate daily step counts, and the amounts of PA under 3 metabolic equivalents (METs) and at 3 METs or more. VO2peak. was measured by incremental cycle exercise tests with indirect calorimetry. The daily step counts, the amount of PA at 3 METs or more, and the VO2peak. were significantly higher in subjects who answered Yes to each question than in those who answered No. Sensitivity and specificity of each question were 62-73% and 45-71% for the amount of PA established with the "Exercise and Physical Activity Reference for Health Promotion 2006 (EPAR2006)". The sum of sensitivity and specificity was the highest when the cutoff value was activity level 2 (sensitivity 73%, specificity 68%). Sensitivity and specificity for VO2max established by EPAR2006 were lower than those for the amount of PA. These results suggest that only answering simple questions with a standard questionnaire is sufficient for estimation of PA levels for specific medical checkups and health guidance, even though the accuracy is somewhat limited.

  12. Investigation of Hg volatile losses from samples and standards during neutron activation analysis

    International Nuclear Information System (INIS)

    Dubinskaya, N.; Dundua, V.; Chikhladze, N.

    1979-01-01

    The losses of Hg from phenol formaldehyde resin - bound standards and hair samples in neutron activation analysis in case of their irradiation in the water filled nuclear reactor channel is studied. The mean losses of Hg during 20-30 hrs irradiation at (2-3)x10 18 n/cm 2 are 15-20% with their stopping at double Al-covers. The mean losses of Hg from standards at 200, 250 and 300 deg C are 30, 61 and 86% respectively and do not occur at 150 deg C after their 5 hour heating. The losses of Hg from hair samples packed in polyethylene tubes through the package walls in experimental conditions are not observed

  13. Whole glove permeation of cyclohexanol through disposable nitrile gloves on a dextrous robot hand and comparison with the modified closed-loop ASTM F739 method 1. No fist clenching.

    Science.gov (United States)

    Mathews, Airek R; Que Hee, Shane S

    2017-04-01

    The aim was to develop a whole glove permeation method for cyclohexanol to generate permeation parameter data for a non-moving dextrous robot hand (normalized breakthrough time t b , standardized breakthrough time t s , steady state permeation rate P s , and diffusion coefficient D). Four types of disposable powderless, unsupported, and unlined nitrile gloves from the same producer were investigated: Safeskin Blue and Kimtech Science Blue, Purple, and Sterling. The whole glove method developed involved a peristaltic pump for water circulation through chemically resistant Viton tubing to continually wash the inner surface of the test glove via holes in the tubing, a dextrous robot hand operated by a microprocessor, a chemically protective nitrile glove to protect the robot hand, an incubator to maintain 35°C temperature, and a hot plate to maintain 35°C at the sampling point of the circulating water. Aliquots of 1.0 mL were sampled at regular time intervals for the first 60 min followed by removal of 0.5 mL aliquots every hour to 8 hr. Quantification was by the internal standard method after gas chromatography-selective ion electron impact mass spectrometry using a non-polar capillary column. The individual glove values of t b and t s differed for the ASTM closed loop method except for Safeskin Blue, but did not for the whole glove method. Most of the kinetic parameters agreed within an order of magnitude for the two techniques. The order of most protective to least protective glove was Blue and Safeskin, then Purple followed by Sterling for the whole gloves. The analogous order for the modified F739 ASTM closed loop method was: Safeskin, Blue, Purple, and Sterling, almost the same as for the whole glove. The Sterling glove was "not recommended" from the modified ASTM data, and was "poor" from the whole glove data.

  14. Final Report, Volume 2, The Development of Qualification Standards for Cast Duplex Stainless Steel

    Energy Technology Data Exchange (ETDEWEB)

    Russell, Steven, W.; Lundin, Carl, D.

    2005-09-30

    The scope of testing cast Duplex Stainless Steel (DSS) required testing to several ASTM specifications, while formulating and conducting industry round robin tests to verify and study the reproducibility of the results. ASTM E562 (Standard Test Method for Determining Volume Fraction by Systematic manual Point Count) and ASTM A923 (Standard Test Methods for Detecting Detrimental Intermetallic Phase in Wrought Duplex Austenitic/Ferritic Stainless Steels) were the specifications utilized in conducting this work. An ASTM E562 industry round robin, ASTM A923 applicability study, ASTM A923 industry round robin, and an ASTM A923 study of the effectiveness of existing foundry solution annealing procedures for producing cast DSS without intermetallic phases were implemented. In the ASTM E562 study, 5 samples were extracted from various cast austenitic and DSS in order to have varying amounts of ferrite. Each sample was metallographically prepared by UT and sent to each of 8 participants for volume fraction of ferrite measurements. Volume fraction of ferrite was measured using manual point count per ASTM E562. FN was measured from the Feritescope{reg_sign} and converted to volume fraction of ferrite. Results indicate that ASTM E562 is applicable to DSS and the results have excellent lab-to-lab reproducibility. Also, volume fraction of ferrite conversions from the FN measured by the Feritescope{reg_sign} were similar to volume fraction of ferrite measured per ASTM E562. In the ASTM A923 applicability to cast DSS study, 8 different heat treatments were performed on 3 lots of ASTM A890-4A (CD3MN) castings and 1 lot of 2205 wrought DSS. The heat treatments were selected to produce a wide range of cooling rates and hold times in order to study the suitability of ASTM A923 to the response of varying amounts on intermetallic phases [117]. The test parameters were identical to those used to develop ASTM A923 for wrought DSS. Charpy V-notch impact samples were extracted from the

  15. Final Report, Volume 2, The Development of Qualification Standards for Cast Duplex Stainless Steel

    Energy Technology Data Exchange (ETDEWEB)

    Russell, Steven, W.; Lundin, Carl, W.

    2005-09-30

    The scope of testing cast Duplex Stainless Steel (DSS) required testing to several ASTM specifications, while formulating and conducting industry round robin tests to verify and study the reproducibility of the results. ASTM E562 (Standard Test Method for Determining Volume Fraction by Systematic manual Point Count) and ASTM A923 (Standard Test Methods for Detecting Detrimental Intermetallic Phase in Wrought Duplex Austenitic/Ferritic Stainless Steels) were the specifications utilized in conducting this work. An ASTM E562 industry round robin, ASTM A923 applicability study, ASTM A923 industry round robin, and an ASTM A923 study of the effectiveness of existing foundry solution annealing procedures for producing cast DSS without intermetallic phases were implemented. In the ASTM E562 study, 5 samples were extracted from various cast austenitic and DSS in order to have varying amounts of ferrite. Each sample was metallographically prepared by UT and sent to each of 8 participants for volume fraction of ferrite measurements. Volume fraction of ferrite was measured using manual point count per ASTM E562. FN was measured from the Feritescope® and converted to volume fraction of ferrite. Results indicate that ASTM E562 is applicable to DSS and the results have excellent lab-to-lab reproducibility. Also, volume fraction of ferrite conversions from the FN measured by the Feritescope® were similar to volume fraction of ferrite measured per ASTM E562. In the ASTM A923 applicability to cast DSS study, 8 different heat treatments were performed on 3 lots of ASTM A890-4A (CD3MN) castings and 1 lot of 2205 wrought DSS. The heat treatments were selected to produce a wide range of cooling rates and hold times in order to study the suitability of ASTM A923 to the response of varying amounts on intermetallic phases [117]. The test parameters were identical to those used to develop ASTM A923 for wrought DSS. Charpy V-notch impact samples were extracted from the castings and wrought

  16. Localized corrosion evaluation of the ASTM F139 stainless steel marked by laser using scanning vibrating electrode technique, X-ray photoelectron spectroscopy and Mott–Schottky techniques

    International Nuclear Information System (INIS)

    Pieretti, Eurico F.; Manhabosco, Sara M.; Dick, Luís F.P.; Hinder, Steve; Costa, Isolda

    2014-01-01

    Graphical abstract: SEM image of pits found at the centred marked area, where the laser beam focused twice. - Highlights: • The effect of laser engraving on the corrosion resistance of the ASTM F139 was studied. • Scanning vibrating electrode technique was used to identify the anodic zone. • Laser engraving of austenitic stainless steels produces highly defective surfaces. • Laser engraving causes large chemical modification of the surface. • Pitting nucleates at the interface between laser affected and unaffected areas. - Abstract: The effect of laser engraving on the corrosion resistance of ASTM F139 stainless steel (SS) has been investigated by electrochemical techniques. The nucleation of localized corrosion on this biomaterial was evaluated by scanning vibrating electrode technique (SVET) in a phosphate buffered saline solution (PBS) of pH 7.4. The Mott–Schottky approach was used to determine the electronic properties of the passive film, also chemically characterized by X-ray photoelectron spectroscopy (XPS). SVET allowed the identification of the anodic zones on the surface of the SS marked by laser technique that were associated with the heat-affected areas. Metallic drops solidified on the laser marked surface dissolved actively at OCP and favoured the nucleation of crevice corrosion, while at the pitting potential, pits nucleate preferentially on the laser marks. XPS results showed that laser engraving caused large chemical modification of the surface. Mott–Schottky results indicated a more defective oxide layer with a larger number of donors on the laser marked surface comparatively to that without marks

  17. Standardization of 32P activity determination method in soil-root cores for root distribution studies

    International Nuclear Information System (INIS)

    Sharma, R.B.; Ghildyal, B.P.

    1976-01-01

    The root distribution of wheat variety UP 301 was obtained by determining the 32 P activity in soil-root cores by two methods, viz., ignition and triacid digestion. Root distribution obtained by these two methods was compared with that by standard root core washing procedure. The percent error in root distribution as determined by triacid digestion method was within +- 2.1 to +- 9.0 as against +- 5.5 to +- 21.2 by ignition method. Thus triacid digestion method proved better over the ignition method. (author)

  18. IAEA standard syllabus of a course to acquire competence on ionizing radiation sources activities

    International Nuclear Information System (INIS)

    Antonova, M.

    2004-01-01

    The specialized training for Ionizing Radiation Sources (IRS) activities is conducted according to educational syllabuses developed for every job position in compliance with art. 12, (3) of new Regulation of the conditions and procedure for acquiring professional qualification and for the procedure for issuing licenses for specialized training and certificates for qualification for use of nuclear energy. A brief review of the modular structure of the standard syllabus of the Postgraduate Educational Course in Radiation Protection and the Safe Use of Radiation Sources is presented in this paper. The content and level of training for categories of persons engaged in different practices are also listed

  19. 76 FR 2056 - Incorporation of Revised ASTM Standards That Provide Flexibility in the Use of Alternatives to...

    Science.gov (United States)

    2011-01-12

    ... development of the nervous system, resulting in learning disabilities. Elemental mercury and other forms of... use of mercury- containing thermometers for certain temperature measurement applications. EPA seeks to... in high temperature applications, such as the use of thermometers in autoclaves, traditionally...

  20. 77 FR 2456 - Incorporation of Revised ASTM Standards That Provide Flexibility in the Use of Alternatives to...

    Science.gov (United States)

    2012-01-18

    ... will be publicly available only in hard copy form. Publicly available docket materials are available in the electronic docket at http://www.regulations.gov , or, if only available in hard copy, at the OPPT... 40 CFR part 86. B. Formatting Changes to Final Rule The regulatory text of this final rule is...

  1. Impact of standards and certification on environmental impairment liability insurance programs

    International Nuclear Information System (INIS)

    Gulledge, W.P.

    1993-01-01

    Environmental impairment liability (EIL) insurance is available for petroleum storage tank and other environmental exposures. Recent standards and performance criteria for leak detection for underground storage tanks (USTs) and other technical standards for USTs have been both a benefit and an interference to risk-based underwriting of storage tank EIL insurance programs. Insurance underwriters and state financial responsibility program administrators are confronted with confusing information to manage these environmental risks. Standards and certification are also key issues for site assessment programs. Recent activities from ASTM and the Institute for Environmental Auditing (IEA) have addressed the need to increase the professional stature of site assessments and environmental management. Reaction and acceptance of these efforts by the users have been mixed. Ultimately, these efforts will greatly impact insurance coverage for environmental risks

  2. European experiences of the proposed ASTM test method for crack arrest toughness of ferritic materials

    International Nuclear Information System (INIS)

    Jutla, T.; Lidbury, D.P.G.; Ziebs, J.; Zimmermann, C.

    1986-01-01

    The proposed ASTM test method for measuring the crack arrest toughness of ferritic materials using wedge-loaded, side-grooved, compact specimens was applied to three steels: A514 bridge steel, A588 bridge steel, and A533B pressure vessel steel. Five sets of results from different laboratories are discussed here. Notches were prepared by spark erosion, although root radii varied from ∝0.1-1.5 mm. Although fast fractures were successfully initiated, arrest did not occur in a significant number of cases. The results showed no obvious dependence of crack arrest toughness, K a , (determined by a static analysis) on crack initiation toughness, K 0 . It was found that K a decreases markedly with increasing crack jump distance. A limited amount of further work on smaller specimens of the A533B steel showed that lower K a values tended to be recorded. It is concluded that a number of points relating to the proposed test method and notch preparation are worthy of further consideration. It is pointed out that the proposed validity criteria may screen out lower bound data. Nevertheless, for present practical purposes, K a values may be regarded as useful in providing an estimate of arrest toughness - although not necessarily a conservative estimate. (orig./HP)

  3. OPTIMIZACION DE LAS PROPIEDADES DE TRANSPORTE IONICO DEL CONCRETO Y SIMULACION DEL ENSAYO ASTM C1202

    Directory of Open Access Journals (Sweden)

    JUAN LIZARAZO MARRIAGA

    2009-01-01

    Full Text Available En este artículo se presentan los resultados de la simulación computacional del flujo de los principales iones presentes (Cl-, OH-, Na+, y K+ en un ensayo ASTM C1202: "Indicación eléctrica de la resistencia del concreto a la penetración de Iones cloruro". Para la modelación se utilizó un esquema de diferencias finitas definido mediante la ecuación de Nernst - Plank con un campo eléctrico variable, la cual describe los movimientos iónicos en un material poroso saturado. Para lograr esto, los resultados de un nuevo ensayo electroquímico diseñado para medir el potencial de membrana, en compañía de la corriente eléctrica, fueron optimizados para obtener los coeficientes intrínsicos de difusión, la composición inicial de la solución de poros, la capacidad de fijación de cloruros y la porosidad de la mezcla de concreto.

  4. The new ASTM Manual for scrubber linings the evolution of a consensus guide

    International Nuclear Information System (INIS)

    Spires, G.V.; Cavallo, J.R.

    1984-01-01

    Faced with spiraling fuel oil costs, power utilities turned to abundant and inexpensive domestic coal and lignite. Conversions and new units designed to burn solid fossil fuels were pursued at a near crisis pace to get out from under the economic penalties associated with the continued use of oil. Coal contains much more sulfur than oil; EPA limitations on SO 2 necessitated costly flue gas desulfurization (FGD) systems when burning coal. Scrubbed gas presented a particularly corrosive environment in and downstream from the FGD system. Problems which often accompany a new technology were soon evident. Materials and linings initially selected were often seen to be inadequate. Severe and rapid degradation was commonplace. This paper traces the development of the recently published ASTM Manual of Protective Linings From Flue Gas Desulfurization System. The scope of the Manual is outlined and some of the more commonly used FGD lining systems are reviewed. Finally some views on the impact of foreseeable changes in regulations and FGD technology on the use and maintenance of FGD system linings are discussed

  5. Characterization of ASTM A335 P92 steel in continuous cooling cycles

    International Nuclear Information System (INIS)

    Xaubet, M. N.; Danón, C. A.; Ramos, C. P.

    2013-01-01

    The operating conditions demanded by Generation IV reactors include high temperatures, higher radiation doses and highly corrosive environments. Among the structural materials proposed both for in-core and out-of-core applications, elevated-temperature P91/P92 ferritic/martensitic steels have been considered. This work studies the transformation behavior and microstructural evolution of ASTM A335 P92 steel in continuous cooling cycles (CCT). The material was austenized at 1050 ºC and afterwards cooled down at controlled rates (300, 50 and 15 ºC/h). The determination and characterization of the phases present in the samples was performed by optical microscopy, field emission scanning electron microscopy, Mössbauer spectroscopy and X-ray diffraction. Samples whose cooling rates were on the limits of the studied range (300 and 15 ºC/h) presented completely martensitic and completely ferritic structures, respectively. The sample cooled down at intermediate rate exhibited, though, a mixed structure of martensite and ferrite. Second-phase precipitation has also been observed in all the samples. (author)

  6. Tekken tests in a steel 'ASTM A 514 GR B' to determine the preheating temperature

    International Nuclear Information System (INIS)

    Quesada, Hector Juan; Zalazar, Monica; Asta, Eduardo Pablo

    2004-01-01

    Cold fissure tests are used to determine the proper preheating temperature in order to prevent fissures during the steel welding process. Tekken tests were carried out on a quenched and tempered high resistance 25.4 mm thick steel (ASTM A514 Gr.B) used in structural applications. The welding was carried out using a FCAW semiautomatic process with gas protection and low hydrogen tubular electrode E110T5-K4. Similar parameters and splicing design were later applied in production. The microstructures of the base material and the welding were determined by optic and electron microscopy. The thermal cycles of the welding were recorded in order to relate the preheating temperature with the cooling time from 800 o C - 500 o C (t 8/5 ) and from 800 o C - 100 o C (tg/1) and the presence or not of fissures. Preheating at 150 o C and t 8/5 greater than 17 s was found to guarantee fissure free welding (CW)

  7. Tekken testing to determine the preheating temperature on ASTM A514 GR B steel

    International Nuclear Information System (INIS)

    Asta, Eduardo; Zalazar, Monica; Quesada, Hector

    2003-01-01

    The cold cracking test methods are used to determine the preheating temperature in order to avoid cracking in steel welding.In this work Tekken tests on high strength quenching and tempering (ASTM A514 GrB) structural steel with a thickness of 25 mm have been made.The welds were done using a FCAW process with gas shielding and basic low hydrogen cored wire E 110T5-K4.The welding parameters and joint design applied in this work are similar to the ones used on site production.The base metal, HAZ and weld metal microstructure have been evaluated by optical and SEM microscopy.Thermal cycles records of each welding have been made to relate preheat temperature with the cooling time on the range of 800-500 degC (t8/5) or 800-100degC (t8/1) and the evidence of crack or no crack condition.Finally, a preheat temperature of 150degC and the cooling time larger than 17 s improve a welding integrity without cracks

  8. Heat treatment temperature influence on ASTM A890 GR 6A super duplex stainless steel microstructure

    International Nuclear Information System (INIS)

    Martins, Marcelo; Casteletti, Luiz Carlos

    2005-01-01

    Duplex and super duplex stainless steels are ferrous alloys with up to 26% chromium, 8% nickel, 5% molybdenum and 0.3% nitrogen, which are largely used in applications in media containing ions from the halogen family, mainly the chloride ion (Cl - ). The emergence of this material aimed at substituting Copper-Nickel alloys (Cupro-Nickel) that despite presenting good corrosion resistance, has mechanical properties quite inferior to steel properties. The metallurgy of duplex and super duplex stainless steel is complex due to high sensitiveness to sigma phase precipitation that becomes apparent, due to the temperatures they are exposed on cooling from solidification as well as from heat treatment processes. The objective of this study was to verify the influence of heat treating temperatures on the microstructure and hardness of ASTM A890/A890M Gr 6A super duplex stainless steel type. Microstructure control is of extreme importance for castings, as the chemical composition and cooling during solidification inevitably provide conditions for precipitation of sigma phase. Higher hardness in these materials is directly associated to high sigma phase concentration in the microstructure, precipitated in the ferrite/austenite interface. While heat treatment temperature during solution treatment increases, the sigma phase content in the microstructure decreases and consequently, the material hardness diminishes. When the sigma phase was completely dissolved by the heat treatment, the material hardness was influenced only due to ferrite and austenite contents in the microstructure

  9. DOE standard: Integration of environment, safety, and health into facility disposition activities. Volume 2: Appendices

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-05-01

    This volume contains the appendices that provide additional environment, safety, and health (ES and H) information to complement Volume 1 of this Standard. Appendix A provides a set of candidate DOE ES and H directives and external regulations, organized by hazard types that may be used to identify potentially applicable directives to a specific facility disposition activity. Appendix B offers examples and lessons learned that illustrate implementation of ES and H approaches discussed in Section 3 of Volume 1. Appendix C contains ISMS performance expectations to guide a project team in developing and implementing an effective ISMS and in developing specific performance criteria for use in facility disposition. Appendix D provides guidance for identifying potential Applicable or Relevant and Appropriate Requirements (ARARs) when decommissioning facilities fall under the Comprehensive Environmental Response, Compensation, Liability Act (CERCLA) process. Appendix E discusses ES and H considerations for dispositioning facilities by privatization. Appendix F is an overview of the WSS process. Appendix G provides a copy of two DOE Office of Nuclear Safety Policy and Standards memoranda that form the bases for some of the guidance discussed within the Standard. Appendix H gives information on available hazard analysis techniques and references. Appendix I provides a supplemental discussion to Sections 3.3.4, Hazard Baseline Documentation, and 3.3.6, Environmental Permits. Appendix J presents a sample readiness evaluation checklist.

  10. Antibacterial activity of Achillea tenuifolia Lam. extract against standard bacteria and isolated strains

    Directory of Open Access Journals (Sweden)

    Sahar Omidpanah

    2016-12-01

    Full Text Available Researchers have been trying to develop new broad-spectrum antibiotics against the infectious diseases caused by bacteria, fungi, viruses, and parasites for many decades. Prolonged usage of the antibiotics has led to the emergence of drug resistance among bacteria; therefore, there is a tremendous need for novel antimicrobial agents from different sources such as plants which are used in traditional medicine. The aim of this study was to evaluate antibacterial effect of Achillea tenuifolia. The plant material was extracted by maceration method using methanol three times at room temperature. The extract was concentrated after removing the solvent by rotary evaporator and then lyophilized using freeze dryer. Inhibitory effect of the extract was examined against four standard bacteria strains and two isolated strains from diseased hen using disk diffusion method and microdilution method to evaluate their inhibition zone diameter (IZD and minimum inhibitory concentration (MIC, respectively. The results showed that the extract of the plant was active against standard strains including Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus and Enterococcus faecalis with IZDs of 10.3±0.5, 14±0.0, 12±0.0 and 11.6±0.5, respectively. However, growths of isolated strains were not inhibited in the presence of the extract. Although, the growths of isolated strains were not inhibited by the plant extract, the standard strains were moderately susceptible to the extract; among those P. aeroginosa was more sensible than other tested strains

  11. DOE standard: Integration of environment, safety, and health into facility disposition activities. Volume 2: Appendices

    International Nuclear Information System (INIS)

    1998-05-01

    This volume contains the appendices that provide additional environment, safety, and health (ES and H) information to complement Volume 1 of this Standard. Appendix A provides a set of candidate DOE ES and H directives and external regulations, organized by hazard types that may be used to identify potentially applicable directives to a specific facility disposition activity. Appendix B offers examples and lessons learned that illustrate implementation of ES and H approaches discussed in Section 3 of Volume 1. Appendix C contains ISMS performance expectations to guide a project team in developing and implementing an effective ISMS and in developing specific performance criteria for use in facility disposition. Appendix D provides guidance for identifying potential Applicable or Relevant and Appropriate Requirements (ARARs) when decommissioning facilities fall under the Comprehensive Environmental Response, Compensation, Liability Act (CERCLA) process. Appendix E discusses ES and H considerations for dispositioning facilities by privatization. Appendix F is an overview of the WSS process. Appendix G provides a copy of two DOE Office of Nuclear Safety Policy and Standards memoranda that form the bases for some of the guidance discussed within the Standard. Appendix H gives information on available hazard analysis techniques and references. Appendix I provides a supplemental discussion to Sections 3.3.4, Hazard Baseline Documentation, and 3.3.6, Environmental Permits. Appendix J presents a sample readiness evaluation checklist

  12. Standardization of the Manufacturing Process of Bee Venom Pharmacopuncture Containing Melittin as the Active Ingredient.

    Science.gov (United States)

    Lee, Yoonmi; Kim, Sung-Geun; Kim, In-Su; Lee, Hwa-Dong

    2018-01-01

    Pharmacopuncture is a unique treatment in oriental medicine that combines chemical stimulation with conventional acupuncture. However, there are no standardized methods for preparing the herbal medicines used in pharmacopuncture, and it is not clear whether the active ingredients are safe and stable. Several studies have investigated nonstandardized preparation processes, but few investigations have addressed safety and preparation methods. Pharmacopuncture may provide an alternative treatment for incurable diseases. However, it must be as valid and safe as standardized medicine. In this way, the present project may contribute to the industrialization of medicine in Korea. It may also expand health insurance coverage by promoting evidence-based medical insurance benefits. Thus, the present study attempted to standardize and improve the raw materials, preparation, and efficacy of bee venom pharmacopuncture (BVP), which is a highly effective technique in oriental medicine. To purify the crude bee venom, the extract was subjected to a stepped-gradient open column (ODS-A; 120 Å, 150 mesh). Using this method, the yield of melittin was significantly increased and the allergen proteins were effectively removed. The melittin content of the purified bee venom was determined using HPLC, and the product was then diluted to 0.1 mg/mL using injection water in preparation for BVP. In the present study, we standardized the purification process to provide safe and stable BVP by increasing the main effective components and eliminating allergens. This study will be seminal in the industrialization and regulation of BVP. We developed an effective strategy for melittin purification and allergen removal from bee venom to create safe BVP.

  13. Standardization of the Manufacturing Process of Bee Venom Pharmacopuncture Containing Melittin as the Active Ingredient

    Directory of Open Access Journals (Sweden)

    Yoonmi Lee

    2018-01-01

    Full Text Available Background. Pharmacopuncture is a unique treatment in oriental medicine that combines chemical stimulation with conventional acupuncture. However, there are no standardized methods for preparing the herbal medicines used in pharmacopuncture, and it is not clear whether the active ingredients are safe and stable. Several studies have investigated nonstandardized preparation processes, but few investigations have addressed safety and preparation methods. Pharmacopuncture may provide an alternative treatment for incurable diseases. However, it must be as valid and safe as standardized medicine. In this way, the present project may contribute to the industrialization of medicine in Korea. It may also expand health insurance coverage by promoting evidence-based medical insurance benefits. Thus, the present study attempted to standardize and improve the raw materials, preparation, and efficacy of bee venom pharmacopuncture (BVP, which is a highly effective technique in oriental medicine. Method. To purify the crude bee venom, the extract was subjected to a stepped-gradient open column (ODS-A; 120 Å, 150 mesh. Using this method, the yield of melittin was significantly increased and the allergen proteins were effectively removed. The melittin content of the purified bee venom was determined using HPLC, and the product was then diluted to 0.1 mg/mL using injection water in preparation for BVP. Results. In the present study, we standardized the purification process to provide safe and stable BVP by increasing the main effective components and eliminating allergens. This study will be seminal in the industrialization and regulation of BVP. Conclusion. We developed an effective strategy for melittin purification and allergen removal from bee venom to create safe BVP.

  14. A standardized approach to study human variability in isometric thermogenesis during low-intensity physical activity

    Directory of Open Access Journals (Sweden)

    Delphine eSarafian

    2013-07-01

    Full Text Available Limitations of current methods: The assessment of human variability in various compartments of daily energy expenditure (EE under standardized conditions is well defined at rest (as basal metabolic rate and thermic effect of feeding, and currently under validation for assessing the energy cost of low-intensity dynamic work. However, because physical activities of daily life consist of a combination of both dynamic and isometric work, there is also a need to develop standardized tests for assessing human variability in the energy cost of low-intensity isometric work.Experimental objectives: Development of an approach to study human variability in isometric thermogenesis by incorporating a protocol of intermittent leg press exercise of varying low-intensity isometric loads with measurements of EE by indirect calorimetry. Results: EE was measured in the seated position with the subject at rest or while intermittently pressing both legs against a press-platform at 5 low-intensity isometric loads (+5, +10, + 15, +20 and +25 kg force, each consisting of a succession of 8 cycles of press (30 s and rest (30 s. EE, integrated over each 8-min period of the intermittent leg press exercise, was found to increase linearly across the 5 isometric loads with a correlation coefficient (r > 0.9 for each individual. The slope of this EE-Load relationship, which provides the energy cost of this standardized isometric exercise expressed per kg force applied intermittently (30 s in every min, was found to show good repeatability when assessed in subjects who repeated the same experimental protocol on 3 separate days: its low intra-individual coefficient of variation (CV of ~ 10% contrasted with its much higher inter-individual CV of 35%; the latter being mass-independent but partly explained by height. Conclusion: This standardized approach to study isometric thermogenesis opens up a new avenue for research in EE phenotyping and metabolic predisposition to obesity

  15. Determination of 25 elements in biological standard reference materials by neutron activation analysis

    International Nuclear Information System (INIS)

    Guzzi, G.; Pietra, R.; Sabbioni, E.

    1974-12-01

    Standard and Certified Reference Materials programme of the JRC includes the determination of trace elements in complex biological samples delivered by the U.S. National Bureau of Standards: Bovine liver (NBS SRM 1577), Orchard Leaves (NBS SRM 1571) and Tomato Leaves. The study has been performed by the use of neutron activation analysis. Due to the very low concentration of some elements, radiochemical groups or elemental separation procedures were necessary. The paper describes the techniques used to analyse 25 elements. Computer assisted instrumental neutron activation analysis with high resolution Ge(Li) spectrometry was considerably advantageous in the determination of Na, K, Cl, Mn, Fe, Rb and Co and in some cases of Ca, Zn, Cs, Sc, and Cr. For low contents of Ca, Mg, Ni and Si special chemical separation schemes, followed by Cerenkov counting have been developped. Two other separation procedures allowing the determination of As, Cd, Ga, Hg, Mo, Cu, Sr Se, Ba and P have been set up. The first, the simplified one involves the use of high resolution Ge(Li) detectors, the second, the more complete one involves a larger number of shorter measurements performed by simpler and more sensitive techniques, such as NaI(Tl) scintillation spectrometry and Cerenkov counting. The results obtained are presented and discussed

  16. Effects of electromyographic and mechanomyographic biofeedback on upper trapezius muscle activity during standardized computer work

    DEFF Research Database (Denmark)

    Madeleine, Pascal; Vedsted, Pernille; Blangsted, Anne Katrine

    2006-01-01

    The purpose of this laboratory study was to investigate the effects of surface electromyography (EMG)- and mechanomyography (MMG)-based audio and visual biofeedback during computer work. Standardized computer work was performed for 3 min with/without time constraint and biofeedback in a randomize...... alternative to EMG in ergonomics. A lowering of the trapezius muscle activity may contribute to diminish the risk of work related musculoskeletal disorders development.......The purpose of this laboratory study was to investigate the effects of surface electromyography (EMG)- and mechanomyography (MMG)-based audio and visual biofeedback during computer work. Standardized computer work was performed for 3 min with/without time constraint and biofeedback in a randomized......) values as well as the work performance in terms of number of completed graph/mouse clicks/errors, the rating of perceived exertion (RPE) and the usefulness of the biofeedback were assessed. The duration of muscle activity above the threshold was significantly lower with MMG compared with EMG as source...

  17. FAKIR: a user-friendly standard for decay heat and activity calculation of LWR fuel

    International Nuclear Information System (INIS)

    Pretesacque, P.; Nimal, J.C.; Huynh, T.D.; Zachar, M.

    1993-01-01

    The shipping casks owned by the transporters and the unloading and storage facilities are subjected by their design safety report to decay heat and activity limits. It is the responsibility of the consignor or the consignee to check the compliance of the fuel assemblies to the shipped or stored with regard to these limiting safety parameters. Considering the diversity of the parties involved in the transport and storage cycle, a standardization has become necessary. This has been achieved by the FAKIR code. The FAKIR development started in 1984 in collaboration between COGEMA, CEA-SERMA and NTL. Its main specifications were to be a user-friendly code, to use the contractual data given in the COGEMA transport and reprocessing sheet 1 as input, and to over-estimate decay heat and activity. Originally based on computerizable standards such as ANSI or USNRC, the FAKIR equations and data libraries are now based on the fully qualified PEPIN/APOLLO calculation codes. FAKIR is applicable to all patterns of irradiation histories, with burn up from 1000 MWd/TeU to 70.000 MWd/TeU and cooling times from 1 second to 100 years. (J.P.N.)

  18. Estimation of improved productivity based on materials substitution in high temperature applications. Use of alloy ASTM A-335 P91

    International Nuclear Information System (INIS)

    Serna, J A; Afanador, W

    2001-01-01

    In ECOPETROL-ICP was carried out an evaluation of the mechanical and micro structural properties of modified 9 Cr-1 Mo alloy, ASTM A-335 Gr. P91, finding higher strength mechanical properties, allowable stresses and creep rupture strength, than the conventional 9 Cr-1 Mo alloy, ASTM A-335 Gr. P9, recommending the alloy P91 as substitute tube material in the radiation zone of the Visbreaking heater of Cartagena's refinery (furnace in revamping process). The results obtained permit a thickness reduction of radiation tubes of material P91 close to 25% and increase the internal volume tube over up 8%, which is a parameter to consider in improving productivity and efficiency process. Also would be obtained a significant savings cost in the material among 5 and 10%. Additionally, expectations of both design and remaining useful life would be seen extensively favored with this change of alloy

  19. Accurate determination of arsenic in arsenobetaine standard solutions of BCR-626 and NMIJ CRM 7901-a by neutron activation analysis coupled with internal standard method.

    Science.gov (United States)

    Miura, Tsutomu; Chiba, Koichi; Kuroiwa, Takayoshi; Narukawa, Tomohiro; Hioki, Akiharu; Matsue, Hideaki

    2010-09-15

    Neutron activation analysis (NAA) coupled with an internal standard method was applied for the determination of As in the certified reference material (CRM) of arsenobetaine (AB) standard solutions to verify their certified values. Gold was used as an internal standard to compensate for the difference of the neutron exposure in an irradiation capsule and to improve the sample-to-sample repeatability. Application of the internal standard method significantly improved linearity of the calibration curve up to 1 microg of As, too. The analytical reliability of the proposed method was evaluated by k(0)-standardization NAA. The analytical results of As in AB standard solutions of BCR-626 and NMIJ CRM 7901-a were (499+/-55)mgkg(-1) (k=2) and (10.16+/-0.15)mgkg(-1) (k=2), respectively. These values were found to be 15-20% higher than the certified values. The between-bottle variation of BCR-626 was much larger than the expanded uncertainty of the certified value, although that of NMIJ CRM 7901-a was almost negligible. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  20. Mechanical properties of ASTM A508 Class 4 steel used in the LWBR closure head and support flange (LWBR Development Program)

    International Nuclear Information System (INIS)

    Allen, R.M.; Hall, J.F.

    1978-07-01

    The LWBR closure head and support flange are manufactured from forgings of ASTM A508 Class 4 steel rather than the ASTM A508 Class 2 forging material more commonly used in reactor vessels and closure heads. Forgings involved were approximately 300,000 pounds and 46,000 pounds. The extensive material test program conducted on ASTM A508 Class 4 LWBR forgings is described. The results of the tests confirm that the A508 Class 4 material used for the LWBR forgings has been quite good through thickness, fracture toughness, and strength properties and fully meet all specified requirements

  1. Twenty new ISO standards on dosimetry for radiation processing

    International Nuclear Information System (INIS)

    Farrar IV, H.

    2000-01-01

    Twenty standards on essentially all aspects of dosimetry for radiation processing were published as new ISO standards in December 1998. The standards are based on 20 standard practices and guides developed over the past 14 years by Subcommittee E10.01 of the American Society for Testing and Materials (ASTM). The transformation to ISO standards using the 'fast track' process under ISO Technical Committee 85 (ISO/TC85) commenced in 1995 and resulted in some overlap of technical information between three of the new standards and the existing ISO Standard 11137 Sterilization of health care products - Requirements for validation and routine control - Radiation sterilization. Although the technical information in these four standards was consistent, compromise wording in the scopes of the three new ISO standards to establish precedence for use were adopted. Two of the new ISO standards are specifically for food irradiation applications, but the majority apply to all forms of gamma, X-ray, and electron beam radiation processing, including dosimetry for sterilization of health care products and the radiation processing of fruit, vegetables, meats, spices, processed foods, plastics, inks, medical wastes, and paper. Most of the standards provide exact procedures for using individual dosimetry systems or for characterizing various types of irradiation facilities, but one covers the selection and calibration of dosimetry systems, and another covers the treatment of uncertainties using the new ISO Type A and Type B evaluations. Unfortunately, nine of the 20 standards just adopted by the ISO are not the most recent versions of these standards and are therefore already out of date. To help solve this problem, efforts are being made to develop procedures to coordinate the ASTM and ISO development and revision processes for these and future ASTM-originating dosimetry standards. In the meantime, an additional four dosimetry standards have recently been published by the ASTM but have

  2. Changes of the mechanical properties of ASTM A 533 type B class 1 (JRQ) steel used in pressure vessels of nuclear power plants

    International Nuclear Information System (INIS)

    Balderrama, Juan J.; Iorio, Antonio F.

    1999-01-01

    The steels used in pressure vessels generally present a non-homogenous microstructure across the thickness of their walls due to their manufacturing process. Average thickness being between 200-250 mm also makes the problem more serious. These facts lead us to think that the variation affects not only microstructure, but also mechanical properties. For this reason the methodology for the evaluation of materials should be standardized for their use before and after radiation by means of a surveillance program which allows us to verify the conditions of the steel of the pressure vessel by using Charpy-v, tensile and fracto-mechanics specimens inside the reactor to obtain information about the condition of the pressure vessel material. In order to analyze these changes, tests were carried out using Charpy-v specimens with different orientation inside the block representing the wall thickness and the corresponding ductile-to-brittle transition curves were made for each direction. The orientations to be considered will be four in all and will be those called TL, LT, ST and LS by ASTM E 399 (1993). The conclusions reached arise from a comparative analysis of the results obtained for each orientation under study and confirm the recommendation by Standards regarding the selection of the TL orientation as the most conservative. (author)

  3. Standardization of Tragopogon graminifolius DC. Extract Based on Phenolic Compounds and Antioxidant Activity

    Directory of Open Access Journals (Sweden)

    Mohammad Hosein Farzaei

    2014-01-01

    Full Text Available Tragopogon graminifolius DC. (TG, Compositae family, is traditionally used for the treatment of various diseases like gastrointestinal and hepatic disorders. The aim of the present study is to standardize extracts from TG used for preparation of different dosage forms in traditional Iranian medicine (TIM based on phenolic compounds. For this purpose, total phenolic content and some phenolic compounds were determined in ethanolic extracts from aerial part and root of TG by HPLC method. Furthermore, antioxidant activity was evaluated using DPPH-HPLC methods. Caffeic acid, gallic acid, ρ-coumaric acid, ferulic acid, and catechin were detected in root and aerial part of TG. ρ-Coumaric acid (6.357 ± 0.014 mg·g−1 was dominant phenolic compound in aerial part followed by ferulic acid (1.24 ± 0.018 mg·g−1. Also, ρ-coumaric acid (2.685 ± 0.031 mg·g−1 was highly abundant in root, followed by catechin (2.067 ± 0.021 mg·g−1. Antioxidant activity of root extract (460.45 ± 0.78 µg Vit.E.E·mL−1 was better than that of aerial part. Generally, phenolic compounds are one of the major constituents of TG and could be used as markers for standardization of dosage forms prepared from this plant. Also, TG demonstrated significant antioxidant activity using DPPH-HPLC method. Phenolic compounds of TG may be responsible for its marked antioxidant properties.

  4. Comparative Study of API 5L X60 and ASTM 572 Gr50 Steel Exposed to Crude Oil and Seawater

    Directory of Open Access Journals (Sweden)

    Marcy Viviana Chiquillo Márquez

    2018-04-01

    Full Text Available In the petroleum industry, the biphasic conditions in storage and separation tanks allow that the material to remain exposed to two different environments, causing its deterioration. In this article, an evaluation is made of the corrosive behavior and Vickers microhardness (HV of two high strength low alloy (HSLA steels and how their surfaces are characterized. The ASTM 572 Gr50 steel showed a lower corrosion rate in all systems after being immersed for 720 and 1440 hours. Characterizing the surface by means of Scanning Electron Microscopy (SEM showed uniform and localized corrosion for the both steels, and revealed that the ASTM 572 Gr50 steel shows pitting corrosion in crude oil systems. The electrochemical results revealed that the corrosion potential of API X60 steel was more negative; however the ASTM 572 Gr50 steel had a higher current density and a lower polarization resistance when immersed in an oil/seawater mixture. It also observed that, after being immersed in the corrosive fluids, the microstructures of the steels were not modified and variations in their microhardness (HV were minute.

  5. Effects of Tempering Temperature and Path on the Microstructural and Mechanical Properties of ASTM Gr.92 Steel

    International Nuclear Information System (INIS)

    Han, C. H.; Baek, J. H.; Kim, S. H.; Lee, C. B.; Kim, Y. K.; Hong, S. I.

    2009-01-01

    SFR (Sodium-Cooled Fast Reactor) is one of the prospective nuclear reactor for the next generation (Gen-IV) systems. The fuel claddings in the SFR are subject to a high fast nuclear irradiation and a high temperature. Fuel technology is a key aspect of an SFR system, with implications for reactor safety, reactor operations, fuel reprocessing technology, and overall system economics. ASTM Gr.92 steel has been considered as the one of the main candidate fuel cladding materials in the design of SFR in that it has higher thermal conductivity as well as dimensional stability under irradiation when compared as austenitic stainless steel. The changes in microstructure and heat-treatment varying M 23 C 6 , MX, M 2 X, and precipitation by ASTM Gr.92 steels to improve high temperature mechanical properties is the attention. According to several researchers, it plays an important role in the mechanical properties of precipitates V, Nb, Cr, C, N as a form of MX and M 2 X precipitates. These fine precipitates formed in the sub- grain by preventing the movement of dislocations in high-temperature mechanical properties will contribute effectively. This study investigated the effects of tempering temperature and heat-treatment path on microstructure and mechanical properties of ASTM Gr.92 steels

  6. Preservice Secondary Teachers' Conceptions from a Mathematical Modeling Activity and Connections to the Common Core State Standards

    Science.gov (United States)

    Stohlmann, Micah; Maiorca, Cathrine; Olson, Travis A.

    2015-01-01

    Mathematical modeling is an essential integrated piece of the Common Core State Standards. However, researchers have shown that mathematical modeling activities can be difficult for teachers to implement. Teachers are more likely to implement mathematical modeling activities if they have their own successful experiences with such activities. This…

  7. Administered activity of Tc-99m MDP for bone scintigraphy, standard or individual dosage?

    International Nuclear Information System (INIS)

    Vestergren, E.; Gretarsdottir, J.; Jacobsson, L.

    2002-01-01

    Background and Aim: Adult patients are generally, irrespective of size, given the same amount of activity for a certain type of nuclear medicine examination, a standard dosage. Identical image quality is essential when comparing different patient studies. The aim of this study is to evaluate different dosage methods for Tc-99m-MDP bone scintigraphy and to investigate whether individual dosage will decrease the variations in image quality between different patients. Material and Methods: 100 consecutive adult patients (aged between 40 and 89 years) undergoing whole body bone scintigraphy were studied. Eight patients were excluded from the study because of abnormal high uptake in the areas of interest. The patient weight and height were registered. The activity in the syringes was measured before and after the injection of about 600 MBq Tc-99m MDP. Scanning was performed, with a dual head gamma camera (Maxxus or Millennium VG, General Electric) equipped with a high-resolution collimator, at approximately 4 hours (mean 3.8 h) post-injection. Regions of interest (ROI) were drawn over the lumbar spine (posterior view), the right femur (anterior view) and also soft tissue background regions for each area. The total counts, maximum counts/pixel and number of pixels in the ROIs were registered. The maximum number of counts/pixel (background-subtracted), SPINEmax and FEMURmax were chosen as the image quality parameters. For each patient, SPINEmax and FEMURmax where recalculated to the number that would have been obtained with standard dosage (exactly 600 MBq), and dosage proportional to body weight, body surface area and body height. All values were corrected to a scanning time 3.8 h after injection. Results: Both with a standard activity dosage and a dosage proportional to body height, SPINEmax decreases with increasing body weight. Dosage proportional to body weight gives increasing values of SPINEmax with increasing body weight. Dosage proportional to body surface area

  8. Validation of a motor activity system by a robotically controlled vehicle and using standard reference compounds.

    Science.gov (United States)

    Patterson, John P; Markgraf, Carrie G; Cirino, Maria; Bass, Alan S

    2005-01-01

    A series of experiments were undertaken to evaluate the accuracy, precision, specificity, and sensitivity of an automated, infrared photo beam-based open field motor activity system, the MotorMonitor v. 4.01, Hamilton-Kinder, LLC, for use in a good laboratory practices (GLP) Safety Pharmacology laboratory. This evaluation consisted of two phases: (1) system validation, employing known inputs using the EM-100 Controller Photo Beam Validation System, a robotically controlled vehicle representing a rodent and (2) biologic validation, employing groups of rats treated with the standard pharmacologic agents diazepam or D-amphetamine. The MotorMonitor's parameters that described the open-field activity of a subject were: basic movements, total distance, fine movements, x/y horizontal ambulations, rearing, and total rest time. These measurements were evaluated over a number of zones within each enclosure. System validation with the EM-100 Controller Photo Beam Validation System showed that all the parameters accurately and precisely measured what they were intended to measure, with the exception of fine movements and x/y ambulations. Biologic validation using the central nervous system depressant diazepam at 1, 2, or 5 mg/kg, i.p. produced the expected dose-dependent reduction in rat motor activity. In contrast, the central nervous system stimulant D-amphetamine produced the expected increases in rat motor activity at 0.1 and 1 mg/kg, i.p, demonstrating the specificity and sensitivity of the system. Taken together, these studies of the accuracy, precision, specificity, and sensitivity show the importance of both system and biologic validation in the evaluation of an automated open field motor activity system for use in a GLP compliant laboratory.

  9. Embrittlement of Intercritically Reheated Coarse Grain Heat-Affected Zone of ASTM4130 Steel

    Science.gov (United States)

    Li, Liying; Han, Tao; Han, Bin

    2018-04-01

    In this investigation, a thermal welding simulation technique was used to investigate the microstructures and mechanical properties of the intercritically reheated coarse grain heat-affected zone (IR CGHAZ) of ASTM4130 steel. The effect of post weld heat treatment (PWHT) on the toughness of IR CGHAZ was also analyzed. The toughness of IR CGHAZ was measured by means of Charpy impact, and it is found that IR CGHAZ has the lowest toughness which is much lower than that of the base metal regardless of whether PWHT is applied or not. The as-welded IR CGHAZ is mainly composed of ferrite, martensite, and many blocky M-A constituents distributing along grain boundaries and subgrain boundaries in a near-connected network. Also, the prior austenite grains are still as coarse as those in the coarse grain heat-affected zone (CGHAZ). The presence of the blocky M-A constituents and the coarsened austenite grains result in the toughness deterioration of the as-welded IR CGHAZ. Most of the blocky M-A constituents are decomposed to granular bainite due to the effect of the PWHT. However, PWHT cannot refine the prior austenite grains. Thus, the low toughness of IR CGHAZ after PWHT can be attributed to two factors, i.e., the coarsened austenite grains, and the presence of the remaining M-A constituents and granular bainite, which are located at grain boundaries and subgrain boundaries in a near-connected network. The absorbed energy of the IR CGHAZ was increased by about 3.75 times, which means that the PWHT can effectively improve the toughness but it cannot be recovered to the level of base metal.

  10. Strychnos nux-vomica seeds: Pharmacognostical standardization, extraction, and antidiabetic activity

    Directory of Open Access Journals (Sweden)

    Rajesh Bhati

    2012-01-01

    Full Text Available Background: Strychnos nux-vomica, commonly known as kuchla, contains strychnine and brucine as main constituents. Minor alkaloids present in the seeds are protostrychnine, vomicine, n-oxystrychnine, pseudostrychnine, isostrychnine, chlorogenic acid, and a glycoside. Seeds are used traditionally to treat diabetes, asthma, aphrodisiac and to improve appetite. Objective: The present study was aimed to evaluate the various pharmacognostical characters and antidiabetic activity of S. nux-vomica seed. Materials and Methods: Pharmacognostical characters were performed as per the WHO guideline. Extraction was carried out in petroleum ether, chloroform, alcohol, hydroalcoholic, aqueous, and phytochemical constituents present in extracts were detected by different chemical tests. Among these extracts hydroalcoholic, aqueous extracts were evaluated for antidiabetic activity on the basis of extractive yield and phytoconstituents, in alloxan-induced diabetic rats using gliclazide as standard. Results: Various analytical values of S. nux-vomica extract were established. Phytoconstituents present in S. nux-vomica extracts were detected. Conclusion: S. nux-vomica extracts show antihyperglycemic activity in experimental animals.

  11. The {sup 124}Sb activity standardization by gamma spectrometry for medical applications

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, M.C.M. de, E-mail: marcandida@yahoo.com.b [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes, Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear (SEMRA/LNMRI/IRD/CNEN), Av. Salvador Allende s/n, Recreio, Rio de Janeiro, RJ, CEP 22780-160 (Brazil); Iwahara, A.; Delgado, J.U.; Poledna, R.; Silva, R.L. da [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes, Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear (SEMRA/LNMRI/IRD/CNEN), Av. Salvador Allende s/n, Recreio, Rio de Janeiro, RJ, CEP 22780-160 (Brazil)

    2010-07-21

    This work describes a metrological activity determination of {sup 124}Sb, which can be used as radiotracer, applying gamma spectrometry methods with hyper pure germanium detector and efficiency curves. This isotope with good activity and high radionuclidic purity is employed in the form of meglumine antimoniate (Glucantime) or sodium stibogluconate (Pentostam) to treat leishmaniasis. {sup 124}Sb is also applied in animal organ distribution studies to solve some questions in pharmacology. {sup 124}Sb decays by {beta}-emission and it produces several photons (X and gamma rays) with energy varying from 27 to 2700 keV. Efficiency curves to measure point {sup 124}Sb solid sources were obtained from a {sup 166m}Ho standard that is a multi-gamma reference source. These curves depend on radiation energy, sample geometry, photon attenuation, dead time and sample-detector position. Results for activity determination of {sup 124}Sb samples using efficiency curves and a high purity coaxial germanium detector were consistent in different counting geometries. Also uncertainties of about 2% (k=2) were obtained.

  12. Activity of the Atomic Energy Society of Japan for compiling the consensus standard on nuclear criticality safety control

    International Nuclear Information System (INIS)

    Yamane, Yoshihiro; Matsumoto, Tadakuni

    2003-01-01

    Activity of the Atomic Energy Society of Japan for compiling the consensus standard on nuclear criticality safety control is presented. The standard recommends an enhancement of nuclear criticality safety throughout a life cycle of facility in terms of a concept of 'barriers against criticality'. (author)

  13. A standardized procedure for using human corpus cavernosum strips to evaluate drug activity.

    Science.gov (United States)

    Mirone, V; Sorrentino, R; di Villa Bianca, R; Imbimbo, C; Palmieri, A; Fusco, F; Tajana, G; Cirino, G

    2000-01-01

    The main problem of using human corpus cavernosum (HCC) tissue to perform bioassay is linked to its limited availability further complicated by the heterogeneous source of the tissues used. Here, we show that gender reassignment is a reliable source of human tissue without major ethical problems. Indeed, the entire corpus cavernosum is obtained from the surgery procedure, which allows creating a standardized procedure to prepare HCC strip. In addition, human tissue, if kept in the fridge in the condition described, does not loose its ability to contract to phenylephrine (PE; alpha agonist), angiotensin II (AG II) and KCl up to 4 days. Furthermore, once contracted with PE, HCC relaxes to acetylcholine (endothelium-dependent mechanism); sodium nitroprusside (endothelium-independent mechanism); cromakalim (CRK), a K(ATP) channel opener; or alprostadil, a synthetic PGE2 (ALPR). In conclusion, we have standardized a procedure that allows the use of HCC strips to evaluate drug activity and/or to study pathophysiological mechanisms with an intact functional human tissue up to 4 days from the surgery procedure.

  14. [Guidelines for certification of Activated clotting time (ACT) according to the EN ISO 22870 standards].

    Science.gov (United States)

    Lasne, Dominique; Bauters, Anne; Le Querrec, Agnès; Bourdin, Carole; Voisin, Sophie

    2015-01-01

    Point of care testing (POCT) must comply with regulatory requirements according to standard EN ISO 22870, which identify biologists as responsible for POCT. Activated clotting time (ACT) is mandatory to monitor on whole blood, anticoagulation achieved by unfractionated heparin during cardiopulmonary bypass (CPB) or cardiac catheterization. This test has no equivalent in the laboratory. With the aim to help the multidisciplinary groups for POCT supervision when they have to analyse the wish of medical departments to use ACT and to help the biologists to be in accordance with the standard, we present the guidelines of the GEHT (Groupe d'étude d'hémostase et thrombose) subcommittee "CEC et Biologie délocalisée" for the certification of ACT. These guidelines are based on the SFBC guidelines for the certification of POCT and on the analysis of the literature to ascertain the justification of clinical need and assess the analytical performance of main analyzers used in France, as well as on a survey conducted with French and Belgian biologists.

  15. Epilobi Hirsuti Herba Extracts Influence the In Vitro Activity of Common Antibiotics on Standard Bacteria

    Directory of Open Access Journals (Sweden)

    Pirvu Lucia

    2016-01-01

    Full Text Available Epilobium genus has been confirmed as an effective source of natural antimicrobials. However, the influence of Epilobi hirsuti herba derived products on usual antibiotics activity has not been studied. In this study, several standardized Epilobi hirsuti herba extracts (EHE were evaluated in order to asses their potential effects on usual antibiotics tested on standard Gram-positive and Gram-negative bacterial strains in vitro. The results emphasized that the bacterial strains ranged from sensitive (MIC values between 50–200 μg GAE mL-1 (S. epidermidis ATCC 12228 to very resistant (E. coli strains, E. faecalis ATCC 29212 being practically immune to EHE. In terms of synergistic interaction, Tetracycline and Ampicillin combinations lead to the most important stimulatory effects, the diameters of the inhibition zone being even 60% bigger compared to the antibiotic alone. Synergistic effects between myricetin(galloyl derivates and Tetracycline were also revealed on P. aeruginosa and E. coli strains. Together, it clearly demonstrated not only EHE’s own antimicrobial properties, but also their capacity to influence the antimicrobial potency of some common antibiotics. These results could be useful for the area of herbal medicines and as potential candidates in managing microbial resistance, but also for physicians and pharmacists using combined antibacterial therapy.

  16. A Standard-Compliant Virtual Meeting System with Active Video Object Tracking

    Science.gov (United States)

    Lin, Chia-Wen; Chang, Yao-Jen; Wang, Chih-Ming; Chen, Yung-Chang; Sun, Ming-Ting

    2002-12-01

    This paper presents an H.323 standard compliant virtual video conferencing system. The proposed system not only serves as a multipoint control unit (MCU) for multipoint connection but also provides a gateway function between the H.323 LAN (local-area network) and the H.324 WAN (wide-area network) users. The proposed virtual video conferencing system provides user-friendly object compositing and manipulation features including 2D video object scaling, repositioning, rotation, and dynamic bit-allocation in a 3D virtual environment. A reliable, and accurate scheme based on background image mosaics is proposed for real-time extracting and tracking foreground video objects from the video captured with an active camera. Chroma-key insertion is used to facilitate video objects extraction and manipulation. We have implemented a prototype of the virtual conference system with an integrated graphical user interface to demonstrate the feasibility of the proposed methods.

  17. A Standard-Compliant Virtual Meeting System with Active Video Object Tracking

    Directory of Open Access Journals (Sweden)

    Chang Yao-Jen

    2002-01-01

    Full Text Available This paper presents an H.323 standard compliant virtual video conferencing system. The proposed system not only serves as a multipoint control unit (MCU for multipoint connection but also provides a gateway function between the H.323 LAN (local-area network and the H.324 WAN (wide-area network users. The proposed virtual video conferencing system provides user-friendly object compositing and manipulation features including 2D video object scaling, repositioning, rotation, and dynamic bit-allocation in a 3D virtual environment. A reliable, and accurate scheme based on background image mosaics is proposed for real-time extracting and tracking foreground video objects from the video captured with an active camera. Chroma-key insertion is used to facilitate video objects extraction and manipulation. We have implemented a prototype of the virtual conference system with an integrated graphical user interface to demonstrate the feasibility of the proposed methods.

  18. MARS-KS code validation activity through the atlas domestic standard problem

    International Nuclear Information System (INIS)

    Choi, K. Y.; Kim, Y. S.; Kang, K. H.; Park, H. S.; Cho, S.

    2012-01-01

    The 2 nd Domestic Standard Problem (DSP-02) exercise using the ATLAS integral effect test data was executed to transfer the integral effect test data to domestic nuclear industries and to contribute to improving the safety analysis methodology for PWRs. A small break loss of coolant accident of a 6-inch break at the cold leg was determined as a target scenario by considering its technical importance and by incorporating interests from participants. Ten calculation results using MARS-KS code were collected, major prediction results were described qualitatively and code prediction accuracy was assessed quantitatively using the FFTBM. In addition, special code assessment activities were carried out to find out the area where the model improvement is required in the MARS-KS code. The lessons from this DSP-02 and recommendations to code developers are described in this paper. (authors)

  19. 75 FR 39871 - Manufactured Home Construction and Safety Standards

    Science.gov (United States)

    2010-07-13

    ... (ANSI A208.2-2004) and would require no change in existing technology for either product to achieve the... certificates required by this section would be amended to refer to the 1997 edition of the ASHRAE Handbook of... for Bathing Facilities. U--ASTM C564 1997 Standard Specification for Rubber 3280.611(d) Gaskets for...

  20. 78 FR 73965 - Manufactured Home Construction and Safety Standards

    Science.gov (United States)

    2013-12-09

    ...-free number). Persons with hearing or speech impairments may access this number through TTY by calling... Steel, and Seals. U--ASTM D4635 2001 Standard Specification 3280.611(d). for Polyethylene Films Made... reduce burdens and maintain flexibility and freedom of choice for the public. This rule is not a...

  1. 78 FR 35085 - Consensus Standards, Light-Sport Aircraft

    Science.gov (United States)

    2013-06-11

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Consensus Standards, Light-Sport... to the provisions of the Sport Pilot and Light-Sport Aircraft rule issued July 16, 2004, and effective September 1, 2004. ASTM International Committee F37 on Light Sport Aircraft developed the new and...

  2. 77 FR 24251 - Consensus Standards, Light-Sport Aircraft

    Science.gov (United States)

    2012-04-23

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Consensus Standards, Light-Sport... relating to the provisions of the Sport Pilot and Light-Sport Aircraft rule issued July 16, 2004, and effective September 1, 2004. ASTM International Committee F37 on Light Sport Aircraft developed the new and...

  3. Ensaios MSCR segundo as normas ASTM D7405-10a e AASHTO T350-14: um estudo de caso envolvendo ligantes asfálticos modificados

    Directory of Open Access Journals (Sweden)

    Matheus David Inocente Domingos

    2016-12-01

    especially the AC+rubber and the AC+rubber+PPA. The AC+PPA showed low stress sensitivity and the best results for the parameters R and Jnr at 3,200 Pa either in the ASTM or the AASHTO protocols, which justifies its choice as the best formulation. The data from the modified asphalt binders suggest that the change from the ASTM protocol to the AASHTO one is recommended.

  4. Standard Master Matrix for Light-Water Reactor Pressure Vessel Surveillance Standards, E706(0)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This master matrix standard describes a series of standard practices, guides, and methods for the prediction of neutron-induced changes in light-water reactor (LWR) pressure vessel (PV) and support structure steels throughout a pressure vessel's service life (Fig. 1). Some of these are existing ASTM standards, some are ASTM standards that have been modified, and some are proposed ASTM standards. General requirements of content and consistency are discussed in Section 6 . More detailed writers' and users' information, justification, and specific requirements for the nine practices, ten guides, and three methods are provided in Sections 3-5. Referenced documents are discussed in Section 2. The summary-type information that is provided in Sections 3 and 4 is essential for establishing proper understanding and communications between the writers and users of this set of matrix standards. It was extracted from the referenced documents, Section 2 and references (1-106) for use by individual writers and users. 1...

  5. Instrumental neutron activation analysis of river habitants by the k(0)-standardization method

    International Nuclear Information System (INIS)

    Momoshima, N.; Toyoshima, T.; Matsushita, R.; Fukuda, A.; Hibino, K.

    2005-01-01

    Analysis of metal concentrations in samples use reference materials for determination, which means elements out of the references are not possible to be determined. The instrumental neutron activation analysis (INAA) with k(O)-standardization method makes possible to determine metals without use of reference materials, which is very attractive for environmental sample analysis, River habitants would be available as a bio-indicator from which river water quality or metal contamination level could be evaluated. We analyzed river fishes and river insects by INAA with k(O)-standardization to examine the possibility of these habitants as a bio-indicator of water system. Small fishes, Oryzias latipes and Gambusia affinis were collected at 3 different rivers every month and river insects, families of Heptageniidae, Baetidae, Perlidae, Hydropsychidae, Psephenidae were collected at a fixed point of the river. The dried samples were irradiated at the research reactor, JRR-4 (3.5MW), JAERI for 10 min and 3 h. 17 elements (Na, K, Ca, Sc, Cr, Mn, Fe, Co, Zn, As, Se, Br, Rb, Sr, Ba, Ce and Sm) were determined by the NAA-k(0) method, showing effectiveness of the present method for environmental sample analysis. The metals observed in the fishes were the highest in Ca and the lowest in Sc, ranging from 10 5 mg/kg-dry weigh in Ca to 10 -2 mg/kg-dry weight in Sc. The differences in metal concentrations were examined by statistical analysis with t-test. Ca, Na and Br concentrations differ between species, Oryzias latipes and Gambusia, and Fe, Sc, Co, Zn and Se concentrations differ among rivers. No difference was observed on K, Rb and Sr concentrations.

  6. Determination of the sensitization of two coatings by steel welding 308l by the EPR-Dl and Astm A-262 practice A techniques

    International Nuclear Information System (INIS)

    Arganis J, C. R.; Zenteno S, J. C.; Robles F, J. L.; Rodriguez M, E.; Vazquez P, A.

    2014-10-01

    A stainless steel 308l coating was deposited by the shielded metal arc welding (SMAW) on steel A36 with a thickness of 4.726 mm in three layers. The sensitization was measured with the technique of Electrochemical Potentiodynamic Reactivation of Double-loop (EPR-Dl), using a portable cell and other of conventional window. The standard Astm A-262, practice A was used to verify the sensitization values. Two samples were used, a welding on a plate of 323 x 172 x 76.2 mm and the second welding on the end of a plate of 12.7 mm of thickness and 280 mm of longitude, with a post-welding process with gas tungsten arc welding (GTAW) with electrode ERNiCr 3 and a process SMAW with electrode ENICRFe 3 . The coating on the plate showed low values of sensitization grade (DOS) in all the points, indicating a very quick heat extraction and an inter dendritic structure type step. The second sample presented DOS values that are related with a structure of low sensitization and the influence of the heat of the post-welding process and a structure of recrystallized grains. (Author)

  7. Recommendations for Autonomous Industrial Vehicle Performance Standards

    OpenAIRE

    Bostelman , Roger

    2016-01-01

    International audience; A workshop was held at the IEEE International Conference on Robotics and Automation, called: “Autonomous Industrial Vehicles: From the Laboratory to the Factory Floor”. Nine research papers were presented followed by a discussion session summarized in this paper. The workshop findings are intended to be useful for developing standards within the ASTM F45 Committee for Driverless Automatic Industrial Vehicles. This paper provides feedback from the discussion listing the...

  8. 20 CFR 667.274 - What health and safety standards apply to the working conditions of participants in activities...

    Science.gov (United States)

    2010-04-01

    ... and safety standards apply to the working conditions of participants in activities under title I of... working conditions of participants in activities under title I of WIA? 667.274 Section 667.274 Employees... working conditions of employees are equally applicable to working conditions of participants engaged in...

  9. Neutron activation analysis of Standard Materials of Comparison IAEA- the corn and soya flour

    International Nuclear Information System (INIS)

    Dadakhanov, J.A.; Sadykov, I.I.; Salimov, M.I.

    2005-01-01

    It is known that maintenance of quality of results of neutron activation analysis (NAA), no less than in other analytical methods, is one of key problems. Thus first of all it is necessary to provide correctness of results. The most correct way of revealing and elimination of regular errors is carrying out of analyses of Standard Samples of Comparison (SSC) by the developed techniques and comparison of the received results with the certificated results. Therefore, the analysis and certification of various SSC is one of the most actual tasks of modern analytical chemistry. One of few organizations engaged in manufacture SSC for NAA, is IAEA which has organized the Project on certification of samples of comparison - a corn and soya flour. Among many laboratories worldwide, in this Project the Laboratory of the Activation Analysis of Pure Materials of Institute of Nuclear Physics Academy of Sciences Republic of Uzbekistan also participated. We carry out series of analyses of samples of corn and soya flour, candidates for standard samples of comparison, by the method of instrumental NAA. The preparing of samples was carried out by the technique described in the technical project applied to these materials. Samples before the analysis dried up at temperature 80 degree C during 24 h. Cooled, weighed and irradiated in the vertical channel of a nuclear reactor of VVR-SM of Institute of Nuclear Physics Academy of Sciences Republic of Uzbekistan during 0,5-1 h (depending on determined elements) with density of a stream of neutrons 1 x 10 14 neutrons/cm 2 sec. Time of cooling from 10 min up to 10 days. Time of measurement from 100 sec up to 3000 sec. Measurements were carried out on gamma spectrometer consisting of HPGe detector GC1518 and digital multichannel analyzer DSA-1000('Canberra', USA). Processing of the spectrometer information carried out with the help of software package Genie-2000. As a result of the carried out analyses we determine contents of 21 elements in

  10. Standardized methods for the production of high specific-activity zirconium-89

    Science.gov (United States)

    Holland, Jason P.; Sheh, Yiauchung; Lewis, Jason S.

    2009-01-01

    Zirconium-89 is an attractive metallo-radionuclide for use in immunoPET due to the favorable decay characteristics. Standardized methods for the routine production and isolation of high purity and high specific-activity 89Zr using a small cyclotron are reported. Optimized cyclotron conditions reveal high average yields of 1.52 ± 0.11 mCi/μA·h at a proton beam energy of 15 MeV and current of 15 μA using a solid, commercially available 89Y-foil target (0.1 mm, 100% natural abundance). 89Zr was isolated in high radionuclidic and radiochemical purity (>99.99%) as [89Zr]Zr-oxalate by using a solid-phase hydroxamate resin with >99.5% recovery of the radioactivity. The effective specific-activity of 89Zr was found to be in the range 5.28 – 13.43 mCi/μg (470 – 1195 Ci/mmol) of zirconium. New methods for the facile production of [89Zr]Zr-chloride are reported. Radiolabeling studies using the trihydroxamate ligand desferrioxamine B (DFO) gave 100% radiochemical yields in 7 days. Small-animal PET imaging studies have demonstrated that free 89Zr(IV) ions administered as [89Zr]Zr-chloride accumulate in the liver whilst [89Zr]Zr-DFO is excreted rapidly via the kidneys within <20 min. These results have important implication for the analysis of immunoPET imaging of 89Zr-labeled monoclonal antibodies. The detailed methods described can be easily translated to other radiochemistry facilities and will facilitate the use of 89Zr in both basic science and clinical investigations. PMID:19720285

  11. Water quality - Determination of tritium activity concentration - Liquid scintillation counting method (International Standard Publication ISO 9698:1989)

    International Nuclear Information System (INIS)

    Stefanik, J.

    1999-01-01

    This International Standard specifies a method for the determination of tritiated water ([ 3 H]H 2 O) activity concentration in water by liquid scintillation counting. The method is applicable to all types of water including seawater with tritium activity concentrations of up to 10 6 Bq/m 3 when using 20 ml counting vials. Below tritium activity concentrations of about 5 x 10 4 Bq/m 3[ 8], a prior enrichment step and/or the measurement of larger sample volumes can significantly improve the accuracy of the determination and lower the limit of detection. Tritium activity concentrations higher than 10 6 Bq/m 3 may be determined after appropriate dilution with distilled water of proven low tritium content. An alternative method for the determination of these higher activities involves increasing the tritium activity concentrations of the internal standard solution. The method is not applicable to the analysis of organically bound tritium; its determination requires an oxidative digestion

  12. A multi-standard active-RC filter with accurate tuning system

    International Nuclear Information System (INIS)

    Ma Heping; Yuan Fang; Shi Yin; Dai, F F

    2009-01-01

    A low-power, highly linear, multi-standard, active-RC filter with an accurate and novel tuning architecture is presented. It exhibits IEEE 802.11 a/b/g (9.5 MHz) and DVB-H (3 MHz, 4 MHz) application. The filter exploits digitally-controlled polysilicon resistor banks and a phase lock loop type automatic tuning system. The novel and complex automatic frequency calibration scheme provides better than 4 corner frequency accuracy, and it can be powered down after calibration to save power and avoid digital signal interference. The filter achieves OIP3 of 26 dBm and the measured group delay variation of the receiver filter is 50 ns (WLAN mode). Its dissipation is 3.4 mA in RX mode and 2.3 mA (only for one path) in TX mode from a 2.85 V supply. The dissipation of calibration consumes 2 mA. The circuit has been fabricated in a 0.35 μm 47 GHz SiGe BiCMOS technology; the receiver and transmitter filter occupy 0.21 mm 2 and 0.11 mm 2 (calibration circuit excluded), respectively.

  13. Novel activities by ebolavirus and marburgvirus interferon antagonists revealed using a standardized in vitro reporter system.

    Science.gov (United States)

    Guito, Jonathan C; Albariño, César G; Chakrabarti, Ayan K; Towner, Jonathan S

    2017-01-15

    Filoviruses are highly lethal in humans and nonhuman primates, likely due to potent antagonism of host interferon (IFN) responses early in infection. Filoviral protein VP35 is implicated as the major IFN induction antagonist, while Ebola virus (EBOV) VP24 or Marburg virus (MARV) VP40 are known to block downstream IFN signaling. Despite progress elucidating EBOV and MARV antagonist function, those for most other filoviruses, including Reston (RESTV), Sudan (SUDV), Taï Forest (TAFV), Bundibugyo (BDBV) and Ravn (RAVV) viruses, remain largely neglected. Thus, using standardized vectors and reporter assays, we characterized activities by each IFN antagonist from all known ebolavirus and marburgvirus species side-by-side. We uncover noncanonical suppression of IFN induction by ebolavirus VP24, differing potencies by MARV and RAVV proteins, and intriguingly, weaker antagonism by VP24 of RESTV. These underlying molecular explanations for differential virulence in humans could guide future investigations of more-neglected filoviruses as well as treatment and vaccine studies. Published by Elsevier Inc.

  14. Application of Scharer's quantitative method for the determination of residual alkaline phosphatase activity in standard Minas

    Directory of Open Access Journals (Sweden)

    C.F. Soares

    2013-08-01

    Full Text Available Milk pasteurization is a critical issue in the dairy industry, and failures in this process can affect final product safety. Scharer's enzymatic method is still traditionally used to verify pasteurization efficiency compliance, and it is based on screening for residual alkaline phosphatase in milk. Although several methods are used to quantify enzymatic activity to assess milk pasteurization efficiency, there is a small amount of published data regarding the use of these methods to quantify alkaline phosphatase in cheese. In this study, the Scharer's modified method was used to determine the levels of residual alkaline phosphatase in standard minas cheese, before and after 20 days of ripening. The cheeses were made using raw or pasteurized milk with the addition of different concentrations of raw milk (0; 0.05%; 0.10%; 0.20%; and 0.50%. In the fresh cheese samples, the method showed a sensitivity of only 0.50% with the addition of raw milk to the pasteurized milk used to make cheese. In addition, levels of up 0.20% of raw milk in pasteurized milk, the concentrations of phenol was inferior to 1μg phenol/g of dairy product which is the preconized indicator value for adequate pasteurization.

  15. A multi-standard active-RC filter with accurate tuning system

    Energy Technology Data Exchange (ETDEWEB)

    Ma Heping; Yuan Fang; Shi Yin [Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083 (China); Dai, F F, E-mail: hpma@semi.ac.c [Department of Electrical and Computer Engineering, Auburn University, Auburn, AL 36849-5201 (United States)

    2009-09-15

    A low-power, highly linear, multi-standard, active-RC filter with an accurate and novel tuning architecture is presented. It exhibits IEEE 802.11 a/b/g (9.5 MHz) and DVB-H (3 MHz, 4 MHz) application. The filter exploits digitally-controlled polysilicon resistor banks and a phase lock loop type automatic tuning system. The novel and complex automatic frequency calibration scheme provides better than 4 corner frequency accuracy, and it can be powered down after calibration to save power and avoid digital signal interference. The filter achieves OIP3 of 26 dBm and the measured group delay variation of the receiver filter is 50 ns (WLAN mode). Its dissipation is 3.4 mA in RX mode and 2.3 mA (only for one path) in TX mode from a 2.85 V supply. The dissipation of calibration consumes 2 mA. The circuit has been fabricated in a 0.35 {mu}m 47 GHz SiGe BiCMOS technology; the receiver and transmitter filter occupy 0.21 mm{sup 2} and 0.11 mm{sup 2} (calibration circuit excluded), respectively.

  16. Federal environmental standards of potential importance to operations and activities at US Department of Energy sites. Draft

    Energy Technology Data Exchange (ETDEWEB)

    Fowler, K.M.; Bilyard, G.R.; Davidson, S.A.; Jonas, R.J.; Joseph, J.

    1993-06-01

    The US Department of Energy (DOE) is now engaged in a program of environmental restoration nationwide across its 45 sites. It is also bringing its facilities into compliance with environmental regulations, decontaminating and decommissioning unwanted facilities, and constructing new waste management facilities. One of the most difficult questions that DOE must face in successfully remediating its inactive waste sites, decontaminating and decommissioning its inactive facilities, and operating its waste management facilities is: ``What criteria and standards should be met?`` Acceptable standards or procedures for determining standards will assist DOE in its conduct of ongoing waste management and pending cleanup activities by helping to ensure that those activities are conducted in compliance with applicable laws and regulations and are accepted by the regulatory community and the public. This document reports on the second of three baseline activities that are being conducted as prerequisites to either the development of quantitative standards that could be used by DOE, or consistent procedures for developing such standards. The first and third baseline activities are also briefly discussed in conjunction with the second of the three activities.

  17. Investigating the effect of coil model losses on computational electromagnetic exposure of an ASTM phantom at 64 MHz MRI.

    Science.gov (United States)

    Kozlov, Mikhail; Horner, Marc; Kainz, Wolfgang; Angelone, Leonardo M

    2017-07-01

    The goal of this work is to investigate the effect of coil losses on the electromagnetic field generated in an ASTM phantom by a birdcage coil. The study was based on different numerical implementations of an RF body coil at 64 MHz, using the same 3D EM and RF circuit co-simulation procedure. The coil quality factor was evaluated with respect to losses due to power feed mismatch and to resistive losses of the coil components. The results of the study showed that the magnetic field at the coil iso-center, normalized to the square root of the whole body specific absorption rate, depends on the coil quality factor.

  18. The fatigue-crack propagation behavior of ASTM A533-B steel tested in vacuo at LWR operating temperatures

    International Nuclear Information System (INIS)

    James, L.A.

    1987-01-01

    The fatigue-crack propagation (FCP) behavior of ASTM A533-B-1 steel was characterized in vacuo at 288 0 C. Tests were conducted at two stress ratios: R = 0.05 and R = 0.7. Results of these tests were compared with results from previous studies for the same type of steel tested in an air environment, and FCP rates in vacuo were generally lower than those in air. Stress ratio effects in vacuo were not as great as those in air, and both stress ratio effects and environmental effects are discussed from the standpoint of crack closure concepts

  19. High Classification Rates for Continuous Cow Activity Recognition using Low-cost GPS Positioning Sensors and Standard Machine Learning Techniques

    DEFF Research Database (Denmark)

    Godsk, Torben; Kjærgaard, Mikkel Baun

    2011-01-01

    activities. By preprocessing the raw cow position data, we obtain high classification rates using standard machine learning techniques to recognize cow activities. Our objectives were to (i) determine to what degree it is possible to robustly recognize cow activities from GPS positioning data, using low...... and their activities manually logged to serve as ground truth. For our dataset we managed to obtain an average classification success rate of 86.2% of the four activities: eating/seeking (90.0%), walking (100%), lying (76.5%), and standing (75.8%) by optimizing both the preprocessing of the raw GPS data...

  20. Cor ASTM: um método simples e rápido para determinar a qualidade do biodiesel produzido a partir de óleos residuais de fritura ASTM color: a simple and fast method for determining quality of biodiesel produced from used cooking oils

    Directory of Open Access Journals (Sweden)

    Verônica Santos de Morais

    2013-01-01

    Full Text Available In this study, 23 biodiesel samples were produced, 20 from used cooking oil and the remaining 3 from refined soybean oil. The following properties were determined in all of the samples (oil and its respective biodiesel: density; viscosity; total acid number and ASTM color. The results indicated high correlation (R > 0.6 between ASTM color of used cooking oil and total acid number of its resultant biodiesel. This high correlation allows prediction of the quality of the biodiesel produced using a simple and fast procedure such as ASTM color.

  1. Instrumental charged-particle activation analysis of several selected elements in biological materials using the internal standard method

    International Nuclear Information System (INIS)

    Yagi, M.; Masumoto, K.

    1987-01-01

    In order to study instrumental charged-particle activation analysis using the internal standard method, simultaneous determinations of several selected elements such as Ca, Ti, V, Fe, Zn, As, Sr, Zr and Mo, in oyster tissue, brewer's yeast and mussel were carried out by using the respective (p, n) reactions and a personal computer-based gamma-ray spectrometer equipped with a micro-robot for sample changing. In the determination constant amounts of Y and La were added to the sample and comparative standard as exotic internal standards. As a result, it was demonstrated that concentrations of the above elements could be determined accurately and precisely. (author)

  2. Nuclear reactor pressure vessel surveillance capsule examinations. Application of American Society for Testing and Materials Standards

    International Nuclear Information System (INIS)

    Perrin, J.S.

    1978-01-01

    A series of pressure vessel surveillance capsules is installed in each commercial nuclear power plant in the United States. A capsule typically contains neutron dose meters, thermal monitors, tensile specimens, and Charpy V-notch impact specimens. In order to determine property changes of the pressure vessel resulting from irradiation, surveillance capsules are periodically removed during the life of a reactor and examined. There are numerous standards, regulations, and codes governing US pressure vessel surveillance capsule programmes. These are put out by the US Nuclear Regulatory Commission, the Boiler and Pressure Vessel Committee of the American Society of Mechanical Engineers, and the American Society for Testing and Materials (ASTM). A majority of the pertinent ASTM standards are under the jurisdiction of ASTM Committee E-10 on Nuclear Applications and Measurements of Radiation Effects. The standards, regulations, and codes pertaining to pressure vessel surveillance play an important role in ensuring reliability of the nuclear pressure vessels. ASTM E 185-73 is the Standard Recommended Practice for Surveillance Tests for Nuclear Reactors. This standard recommends procedures for both the irradiation and subsequent testing of surveillance capsules. ASTM E 185-73 references many additional specialized ASTM standards to be followed in specific areas of a surveillance capsule examination. A key element of surveillance capsule programmes is the Charpy V-notch impact test, used to define curves of fracture behaviour over a range of temperatures. The data from these tests are used to define the adjusted reference temperature used in determining pressure-temperature operating curves for a nuclear power plant. (author)

  3. Accession Medical Standards Analysis and Research Activity (AMSARA), 2015 Annual Report

    Science.gov (United States)

    2016-03-01

    disorders are listed under the same standard within the medical standards for enlistment regardless of the type of curvature: scoliosis, lordosis ...spinal curvature disorders are referred to generically as scoliosis, estimates of the prevalence of lordosis and kyphosis are difficult to obtain...the specific type of spinal curvature disorder (i.e. scoliosis, lordosis , kyphosis) associated with disqualification or waiver could be

  4. Regulations, guidelines, standards, and policies pertaining to decontamination and decommissioning activities: A literature review

    International Nuclear Information System (INIS)

    Cowgill, M.G.

    1993-09-01

    A literature review has been conducted of the existing rules, regulations, and guidelines pertaining to the decontamination and decommissioning of nuclear facilities. Included in the survey are US Government documents, national (industrial) standards, international standards and guidelines, and the regulations issued by various national governments, such as the United Kingdom, Canada, and Germany

  5. 76 FR 30970 - Agency Information Collection Activities; Submission for OMB Review; Comment Request; Standard on...

    Science.gov (United States)

    2011-05-27

    ... for OMB Review; Comment Request; Standard on the Control of Hazardous Energy-- Lockout/Tagout ACTION... Hazardous Energy--Lockout/Tagout,'' to the Office of Management and Budget (OMB) for review and approval for... of Collection: Standard on the Control of Hazardous Energy-- Lockout/Tagout. OMB Control Number: 1218...

  6. Capturing the Complex, Situated, and Active Nature of Teaching through Inquiry-Oriented Standards for Teaching

    Science.gov (United States)

    Sinnema, Claire; Meyer, Frauke; Aitken, Graeme

    2017-01-01

    Given widespread acceptance of the role of teaching in improving student outcomes, it is not surprising that policy makers have turned to teaching standards as a lever for educational improvement. There are, however, long-standing critiques of standards that suggest they are reductionist and promote a dualism between theory and practice. Our…

  7. Evaluation of antifungal activity of standardized extract of Salvia rhytidea Benth. (Lamiaceae) against various Candida isolates.

    Science.gov (United States)

    Salari, S; Bakhshi, T; Sharififar, F; Naseri, A; Ghasemi Nejad Almani, P

    2016-12-01

    Salvia species have long been described in traditional medicine for various indications. Owing to the widespread use of this genus by ethnic populations, especially for various infections ranging from skin disease to gastrointestinal disorders, we were encouraged to determine whether Salvia rhytidea could be effective against fungal infections. Given the increased incidence of candidiasis in the past decade, limits on the use of antifungal drugs, emergence of azole-resistant Candida species and increased incidence of treatment failures, it is necessary to identify a novel agent with antifungal properties. Aim of the study was to evaluate the antifungal properties of S. rhytidea against various Candida isolates. In this study, at first rosmarinic acid content of plant extract was determined. A total of 96 Candida isolates were tested, including the following species: Candida albicans (n=42), Candida glabrata (n=16), Candida tropicalis (n=11), Candida krusei (n=9), Candida parapsilosis (n=9), Candida lusitaniae (n=7) and Candida guilliermondii (n=2). The in vitro antifungal activity of methanolic extracts of S. rhytidea Benth. was evaluated against Candida isolates and compared with that of the standard antifungal drug nystatin by using a broth microdilution method, according to CLSI. Phytochemical screening results showed that the methanolic extract of S. rhytidea Benth. was rich in flavonoids and tannins. The minimal inhibitory concentration (MIC) and minimum fungicidal concentration (MFC) values of S. rhytidea Benth. ranged from 3.125 to>100μg/ml and 6.25 to>100μg/ml respectively. The growth inhibition value displayed that C. tropicalis, C. krusei and C. albicans isolates were most susceptible to S. rhytidea. Findings show that S. rhytidea possesses an antifungal effect against Candida isolates. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  8. Nondestructive testing standards and the ASME code

    International Nuclear Information System (INIS)

    Spanner, J.C.

    1991-04-01

    Nondestructive testing (NDT) requirements and standards are an important part of the ASME Boiler and Pressure Vessel Code. In this paper, the evolution of these requirements and standards is reviewed in the context of the unique technical and legal stature of the ASME Code. The coherent and consistent manner by which the ASME Code rules are organized is described, and the interrelationship between the various ASME Code sections, the piping codes, and the ASTM Standards is discussed. Significant changes occurred in ASME Sections 5 and 11 during the 1980s, and these are highlighted along with projections and comments regarding future trends and changes in these important documents. 4 refs., 8 tabs

  9. Moessbauer spectroscopy study on the corrosion resistance of plasma nitrided ASTM F138 stainless steel in chloride solution

    International Nuclear Information System (INIS)

    Souza, S.D. de; Olzon-Dionysio, M.; Basso, R.L.O.; Souza, S. de

    2010-01-01

    Plasma nitriding of ASTM F138 stainless steel samples has been carried out using dc glow discharge under 80% H 2 -20% N 2 gas mixture, at 673 K, and 2, 4, and 7 h time intervals, in order to investigate the influence of treatment time on the microstructure and the corrosion resistance properties. The samples were characterized by scanning electron microscopy, glancing angle X-ray diffraction and conversion electron Moessbauer spectroscopy, besides electrochemical tests in NaCl aerated solution. A modified layer of about 6 μm was observed for all the nitrided samples, independent of nitriding time. The X-ray diffraction analysis shows broad γ N phase peaks, signifying a great degree of nitrogen supersaturation. Besides γ N, the Moessbauer spectroscopy results indicated the occurrence of γ' and ε phases, as well as some other less important phases. Corrosion measurements demonstrate that the plasma nitriding time affects the corrosion resistance and the best performance is reached at 4 h treatment. It seems that the ε/γ' fraction ratio plays an important role on the resistance corrosion. Additionally, the Moessbauer spectroscopy was decisive in this study, since it was able to identify and quantify the iron phases that influence the corrosion resistance of plasma nitrided ASTM F138 samples.

  10. Anodic Protection performance of Steels ASTM A 516-60 And JIS G 3131 SPHC In Concentrated Sulfuric Acid

    International Nuclear Information System (INIS)

    Harsisto; Ginting, Immanuel; Eddy, D.C

    2001-01-01

    One of the methods to protect a carbon steel material from corrosion attack of sulfuric acid environment is with anodic protection. This research was intended to investigate the effect of anodic protection quickened with potential polarization, The material under investigation were ASTM A 516 and JIS G 3131-SPHC in highly concentrated H 2 SO 4 solution. The results showed that potential that was effective for anodic protection in ASTM A 516-60 were at 236-436 mV for 75%, 276-476 mV for 80%, 264-514 mV for 85%,285-485 mV for 90%, and 231-431 mV for 97% H 2 SO 4 so that in JlS G 3131-SPHC were at 303 -503 mV for 75%, 290-490 mV for 80%, 269- 516 mV for 85%, 264-514 mV for 90%, and 287 -487 mV for 97% H 2 SO 4

  11. Effect of C content on the mechanical properties of solution treated as-cast ASTM F-75 alloys.

    Science.gov (United States)

    Herrera, M; Espinoza, A; Méndez, J; Castro, M; López, J; Rendón, J

    2005-07-01

    The mechanical properties of solution treated ASTM F-75 alloys with various carbon contents have been studied. Alloys cast under the same conditions were subjected to solution treatment for several periods and then their tensile properties were evaluated. In the as-cast conditions, the alloys exhibited higher strength values with increasing carbon content whereas their ductility was not significantly affected. For the solution treated alloys, the variation of the strength was characterized by a progressive increase for short treatment times until a maximum value was achieved, which was followed by a diminution in this property for longer treatment times. This behavior was more accentuated for the case of the alloys with medium carbon contents, which also exhibited the highest values of strength. Furthermore, the alloy's ductility was enhanced progressively with increasing solution treatment time. This improvement in ductility was significantly higher for the medium carbon alloys compared with the rest of the studied alloys. Thus, high and low carbon contents in solution treated ASTM F-75 alloys did not produced sufficiently high tensile properties.

  12. New internal standard method for activation analysis and its application. Determination of Co, Ni, Rb, Sr in pepperbush by means of photon activation

    Energy Technology Data Exchange (ETDEWEB)

    Yagi, M.; Masumoto, K. (Tohoku Univ., Sendai (Japan). Lab. of Nuclear Science)

    1984-08-01

    A new internal standard method for activation analysis has been developed. In this method a suitable element present originally in the sample is used as an internal standard and the comparative standard is prepared by applying the standard addition method to the duplicated sample. The present method has the great advantages that the comparative standard spiked with the element of interest has the same matrix as the sample, and then the amount of the element to be determined in the sample can be evaluated easily by using a very simple equation even though the sample and comparative standard are irradiated separately by particles with different flux. Neither correction of the inhomogeneities of flux between the sample and comparative standard, nor that of the self-shielding effects are necessary for the present method. The usefulness of the method was examined through the determination of Co, Ni, Rb and Sr in pepperbush by means of photon activation, and the precision and accuracy of the method were proved to be valid. 29 refs.

  13. Hydrogen Codes and Standards: An Overview of U.S. DOE Activities

    International Nuclear Information System (INIS)

    James M Ohi

    2006-01-01

    The Hydrogen, Fuel Cells, and Infrastructure Technologies (HFCIT) Program of the U.S. Department of Energy (DOE) and the National Renewable Energy Laboratory (NREL), with the help of leading standards and model code development organizations, other national laboratories, and key stakeholders, are developing a coordinated and collaborative government-industry effort to prepare, review, and promulgate hydrogen codes and standards needed to expedite hydrogen infrastructure development. The focus of this effort is to put in place a coordinated and comprehensive hydrogen codes and standards program at the national and international levels. This paper updates an overview of the U.S. program to facilitate and coordinate the development of hydrogen codes and standards that was presented by the author at WHEC 15. (authors)

  14. 76 FR 16728 - Announcement of the American Petroleum Institute's Standards Activities

    Science.gov (United States)

    2011-03-25

    ... (Specific Gravity), or API Gravity of Crude Petroleum and Liquid Petroleum Products by Hydrometer Method... by Pressure Hydrometer, 3rd Ed. MPMS Chapter 9.3, Standard Test Method for Density, Relative Density...

  15. Evolution of activities in international biological standardization since the early days of the Health Organisation of the League of Nations.

    Science.gov (United States)

    Sizaret, P

    1988-01-01

    The main activities in international biological standardization during the 18 years that followed the first international biological standardization meeting in London in 1921 were concerned with expressing the potencies of test preparations in comparison with reference materials. After the Second World War, however, it became clear that the testing of biological substances against international reference materials was only one among several measures for obtaining safe and potent products. The activities in international biological standardization were therefore widened so that, by the strict observance of specific manufacturing and control requirements, it was possible to gain further in safety and efficacy. At the end of 1987, 42 international requirements for biological substances were available and were being used as national requirements, sometimes after minor modification, by the majority of WHO's Member States. This is of utmost importance for the worldwide use of safe and potent biological products, including vaccines.

  16. Determinations of silicon and phosphorus in Pepperbush standard reference material by neutron activation and x-ray fluorescence methods

    International Nuclear Information System (INIS)

    Mizumoto, Yoshihiko; Nishio, Hirofumi; Hayashi, Takeshi; Kusakabe, Toshio; Iwata, Shiro.

    1987-01-01

    Silicon and phosphorus contents in Pepperbush standard reference material were determined by neutron activation and X-ray fluorescence methods. In neutron activation analysis, β-ray spectra of 32 P produced by 31 P(n,γ) 32 P reaction on Pepperbush and standard samples were measured by a low background β-ray spectrometer. In X-ray fluorescence analysis, the standard samples were prepared by mixing the Pepperbush powder with silicon dioxide and diammonium hydrogenphosphate. Characteristic X-rays from the samples were analyzed by a wavelength dispersive X-ray fluorescence spectrometer. From the β and X-ray intensities, silicon and phosphorus contents in Pepperbush were determined to be 1840 ± 80 and 1200 ± 50 μg g -1 , respectively. (author)

  17. Determinations of elements in pepperbush standard reference material by neutron activation and X-ray fluorescence analyses

    International Nuclear Information System (INIS)

    Mizumoto, Yoshihiko; Okada, Takayuki; Tatsumi, Toshiya; Kusakabe, Toshio; Katsurayama, Kousuke; Iwata, Shiro.

    1988-01-01

    Elemental contents in Pepperbush standard reference material have been determined by neutron activation and X-ray fluorescence analyses. The standard samples of orchard leaves, tomato leaves, pine needles and Kale are used for the experiment. In the neutron activation analysis, gamma-ray spectra of nuclei produced by (n,γ) reaction on Pepperbush and standard samples are measured with Ge detectors. In the X-ray fluorescence analysis, the samples are excited with X-rays from X-ray tube with rhodium anode, and the characteristic X-rays from samples are measured with a proportional counter or NaI(Tl) detector. From the gamma- and X-ray intensities, the elemental contents in Pepperbush are determined. As a result, the contents of seventeen elements, such as sodium, calcium, iron, etc., in Pepperbush are determined. (author)

  18. Internal standard method for determination of gallium and some trace elements in bauxite by neutron activation analysis

    International Nuclear Information System (INIS)

    Chen, S.G.; Tsai, H.T.

    1983-01-01

    A method is described for the determination of gallium and other trace elements such as Ce, Cr, Hf, Lu and Th in bauxite by the technique of neutron activation analysis using gold as internal standard. Isopropyl ether was used as organic extractant radioactive gallium from the sample. This method yields very good accuracy with a relative error of +-3%. (author)

  19. Standardization of quantum technologies and QKD activities within ETSI (Conference Presentation)

    Science.gov (United States)

    Lenhart, Gaby

    2016-04-01

    In order to establish new ICT technologies successfully on the market it is essential to build trust within any potential users. This is especially true for technologies which are based upon paradigms that are not yet familiar to these users, such as quantum technologies. Technical standards are an excellent means to offer a certain degree of legal reliability and technical interoperability that is required by industry for commercial take up. While such standards on the one hand must be clear enough to provide strict rules for implementers, on the other hand they also must remain flexible enough to not restrict progress in further research and development on the standardized technology. Hence such standards have to be produced by a wide variety of stakeholders taking into account all their different needs. The paper will provide some insight into the general mechanisms of standardization and their relation to quantum technologies. Alongside with the relevance of standardization as an enabler for certification of quantum based technologies it will explain its potential for securing intellectual property. In its first part paper will concentrate on the advantages of standardization and discuss fears some of the stakeholders share, in detail. The second part will focus on the technical work going on in ETSI in relation to quantum technologies. In 2008 ETSI created a standards work group on Quantum Key Distribution, the ETSI ISG QKD and more recently a group on Quantum-Safe Cryptography, the ETSI ISG QSC. A significant part of the technical work of these groups has already been published and will be introduced in the following. However a big share of work is still ongoing and lot more is planned for the future, as are continuous revisions and updates of the published specifications. This standardization work covers several levels: It starts of by problem statements in the form of use cases, from which technical requirements can be derived. These requirements then form

  20. Development of departmental standard for traceability of measured activity for 131I therapy capsules used in nuclear medicine

    International Nuclear Information System (INIS)

    Ravichandran, Ramamoorthy; Binukumar, J.P.

    2011-01-01

    International Basic Safety Standards (International Atomic Energy Agency, IAEA) provide guidance levels for diagnostic procedures in nuclear medicine indicating the maximum usual activity for various diagnostic tests in terms of activities of injected radioactive formulations. An accuracy of ± 10% in the activities of administered radio-pharmaceuticals is being recommended, for expected outcome in diagnostic and therapeutic nuclear medicine procedures. It is recommended that the long-term stability of isotope calibrators used in nuclear medicine is to be checked periodically for their performance using a long-lived check source, such as 137 Cs, of suitable activity. In view of the un-availability of such a radioactive source, we tried to develop methods to maintain traceability of these instruments, for certifying measured activities for human use. Two re-entrant chambers ((HDR 1000 and Selectron Source Dosimetry System (SSDS)) with 125 I and 192 Ir calibration factors in the Department of Radiotherapy were used to measure Iodine-131 ( 131 I) therapy capsules to establish traceability to Mark V isotope calibrator of the Department of Nuclear Medicine. Special nylon jigs were fabricated to keep 131 I capsule holder in position. Measured activities in all the chambers showed good agreement. The accuracy of SSDS chamber in measuring 192 Ir activities in the last 5 years was within 0.5%, validating its role as departmental standard for measuring activity. The above method is adopted because mean energies of 131 I and 192 Ir are comparable. (author)

  1. 76 FR 39852 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe (Over 41/2

    Science.gov (United States)

    2011-07-07

    ..., or equivalent, to the American Society for Testing and Materials (``ASTM'') A-53, ASTM A-106, ASTM A-333, ASTM A- 334, ASTM A-589, ASTM A-795, and the American Petroleum Institute (``API'') 5L... American Society of Mechanical Engineers (``ASME'') code stress levels. Alloy pipes made to ASTM A-335...

  2. 77 FR 13079 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe (Over 41/2

    Science.gov (United States)

    2012-03-05

    ... produced, or equivalent, to the American Society for Testing and Materials (``ASTM'') A-53, ASTM A-106, ASTM A-333, ASTM A- 334, ASTM A-589, ASTM A-795, and the American Petroleum Institute (``API'') 5L... American Society of Mechanical Engineers (``ASME'') code stress levels. Alloy pipes made to ASTM A-335...

  3. Standard of care of erectile dysfunction in U.S. Air Force aircrew and active duty not on flying status.

    Science.gov (United States)

    Nast, Justin B

    2014-11-01

    In 2011, over 3,000 active duty U.S. Air Force (USAF) members were prescribed a phosphodiesterase inhibitor (PDEI). PDEIs are first-line therapy for treating erectile dysfunction and can have significant side effects that could impact aircrew performance. In total, 200 eligible subject records were randomly sampled from the active duty USAF population of those males filling a prescription for a PDEI in June 2011; 100 of those records were from aviators. The electronic records were reviewed and scored to determine if USAF aeromedical standards for prescribing PDEIs were followed, with a minimum score of 0 for no standards met and a maximum of 3 for all standards met. The average score for both groups was 1, with no significant difference between the group scores. A proper aeromedical disposition was documented in 67% of the aviator records. Although there was no significant difference in standard of care for aviators and nonaviators, the overall documented standard of care was poor. Lack of documentation was the primary reason for the low scores and the low percentage of properly rendered aeromedical dispositions. Proper medical record documentation is important for evaluating quality of care and ensuring compliance with regulations in an Air Force aviator population. Reprint & Copyright © 2014 Association of Military Surgeons of the U.S.

  4. Trend report on international and Japanese standardization activities for bioceramics and tissue engineered medical products

    Directory of Open Access Journals (Sweden)

    Sadami Tsutsumi

    2010-01-01

    Full Text Available Since porous and injectable bioceramics have recently been utilized often as scaffolds for bone regenerative medicine, the need for their standardization has increased. One of the standard proposals in ISO/TC150 and JIS has been a draft for characterization of the porous bioceramic scaffolds in both micro- and macro-scopic aspects. ISO/TC150/SC7 (Tissue engineered medical products has been co-chaired by Professor J E Lemons, Department of Surgery, University of Alabama at Birmingham and Dr R Nakaoka, Division of Medical Devices, National Institute of Health Sciences, Japan. The scope of SC7 has been specified as 'Standardization for the general requirements and performance of tissue engineered medical products with the exclusion of gene therapy, transplantation and transfusion'.

  5. Determination of multielement in optical waveguide and standard reference materials by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Kobayashi, K.; Kudo, K.

    1979-01-01

    Trace amounts of transition elements (Co, Cr, Cu, Fe, Mn and V) and other seven elements in optical waveguide samples were determined by INAA. The contents of impurities in ultre-pure materials are less than those of high-purity materials and of G.R. grade. The increase of contamination of trace transition elements and iridium from furnace or crucible are observed in the production of optical glass fibers. Up to seventeen elements were determined in five NBS biological standard reference materials: Oyster Tissue: SRM-1566, Brewers Yeast: SRM-1569, Spinach: SRM-1570, Orchard Leaves: SRM-1571 and Tuna Fish, and in four Japanese biological standard reference materials: Tea Leaves B and C, Pepperbush and Shark Meat. The analytical results in NBS and Japanese standard reference materials are in good agreement with published values and certified values by NBS. (author)

  6. Photon activation analysis using internal standards: some studies of the analysis of environmental materials

    Energy Technology Data Exchange (ETDEWEB)

    Masumoto, K; Yagi, M

    1986-01-01

    The authors report the application of the internal standard method to the simultaneous determination of trace elements in environmental reference materials. The standard soil material used was IAEA CRM Soil-5. The power plant fly ash reference used was NBS SRM-1633a. Fifteen target elements, including As, Ba and Ce, were determined. Internal standards were supplied by six elements, including Na and Mg. Although there were several interfering elements, their effect could be eliminated by utilizing more than one gamma-ray peak and carrying out appropriate corrections. The values determined for most of the target elements were well within the certified range. Measured concentrations were of the orders of 10 to 1000 ..mu..g/g. 6 references, 2 figures, 5 tables.

  7. Math starters 5- to 10-minute activities aligned with the common core math standards, grades 6-12

    CERN Document Server

    Muschla, Judith A; Muschla, Erin

    2013-01-01

    A revised edition of the bestselling activities guide for math teachers Now updated with new math activities for computers and mobile devices-and now organized by the Common Core State Standards-this book includes more than 650 ready-to-use math starter activities that get kids quickly focused and working as soon as they enter the classroom. Ideally suited for any math curriculum, these high-interest problems spark involvement in the day's lesson, help students build skills, and allow teachers to handle daily management tasks without wasting valuable instructional time. A newly updated edit

  8. Solar wind and geomagnetism: toward a standard classification of geomagnetic activity from 1868 to 2009

    Directory of Open Access Journals (Sweden)

    J. L. Zerbo

    2012-02-01

    Full Text Available We examined solar activity with a large series of geomagnetic data from 1868 to 2009. We have revisited the geomagnetic activity classification scheme of Legrand and Simon (1989 and improve their scheme by lowering the minimum Aa index value for shock and recurrent activity from 40 to 20 nT. This improved scheme allows us to clearly classify about 80% of the geomagnetic activity in this time period instead of only 60% for the previous Legrand and Simon classification.

  9. Determination of the sensitization of two coatings by steel welding 308l by the EPR-Dl and Astm A-262 practice A techniques; Determinacion de la sensibilizacion de dos revestimientos por soldadura de acero 308L por las tecnicas EPR-DL y ASTM A-262 practica A

    Energy Technology Data Exchange (ETDEWEB)

    Arganis J, C. R.; Zenteno S, J. C.; Robles F, J. L.; Rodriguez M, E.; Vazquez P, A., E-mail: carlos.arganis@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2014-10-15

    A stainless steel 308l coating was deposited by the shielded metal arc welding (SMAW) on steel A36 with a thickness of 4.726 mm in three layers. The sensitization was measured with the technique of Electrochemical Potentiodynamic Reactivation of Double-loop (EPR-Dl), using a portable cell and other of conventional window. The standard Astm A-262, practice A was used to verify the sensitization values. Two samples were used, a welding on a plate of 323 x 172 x 76.2 mm and the second welding on the end of a plate of 12.7 mm of thickness and 280 mm of longitude, with a post-welding process with gas tungsten arc welding (GTAW) with electrode ERNiCr{sub 3} and a process SMAW with electrode ENICRFe{sub 3}. The coating on the plate showed low values of sensitization grade (DOS) in all the points, indicating a very quick heat extraction and an inter dendritic structure type step. The second sample presented DOS values that are related with a structure of low sensitization and the influence of the heat of the post-welding process and a structure of recrystallized grains. (Author)

  10. Harmonization of standards for permissible radionuclide activity concentrations in foodstuffs in the long term after the Chernobyl accident.

    Science.gov (United States)

    Balonov, Mikhail I; Kashparov, Valery; Nikolaenko, Elena; Berkovsky, Volodymyr; Fesenko, Sergey

    2018-04-16

    The article critically examines the practice of post-Chernobyl standardization of radionuclide concentrations (mainly 137Cs and 90Sr) in food products in the USSR and the successor countries of Belarus, Russia and Ukraine. Recommendations are given on potential harmonization of these standards of radionuclide concentrations in food products among three countries, taking into account substantial international experience. We propose to reduce the number of product groups for standardization purpose from the current several dozens to three to five groups to optimize radiation control and increase the transparency of the process. We recommend five product groups for the standardization of 137Cs and three groups for 90Sr in food in radiocontaminated areas. The values of standards for individual product groups are recommended to be set proportionally to the measured specific activity in each of these groups, which will reduce unreasonable food rejection. The standards might be set for the entire country, and could be also used to control imports from other countries as well as exports to other countries. The developed recommendations were transferred in 2015-2016 to the regulatory authorities of the three countries. © 2018 IOP Publishing Ltd.

  11. Testing of adsorbents used in nuclear power plant air cleaning systems using the open-quotes Newclose quotes standards

    International Nuclear Information System (INIS)

    Freeman, W.P.

    1993-01-01

    Ever since the publication of the NRC Information Notice No. 87-32: Deficiencies in the Testing of Nuclear-Grade Activated Charcoal, nuclear power facilities in the US have struggled in their efforts to open-quotes...review the information for applicability to their facilities and consider action, if appropriate ...close quotes as stated in the notice. The encouragement of resident NRC inspectors at some nuclear power facilities has prompted a variety of responses ranging from no change at all in testing requirements to contemplated changes in plant technical specifications. This confusion is the result of a couple factors. The first factor is the lack of a current revision to NRC Regulatory Guide 1.52, the basic document used in nuclear power plant technical specifications for the testing of engineered-safety feature (ESF) post accident air cleaning systems. The second factor is the standards that have been written since the last revision of Reg. Guide 1.52 which include two revision of ANSI N509 and N510, two revisions of RDT M16-1T, two version of ASTM D3803, two versions of ASTM D4069, and three versions of an SME code AG-1. Few of the standards and codes listed above are commensurate with each other and, thus, present a nearly insolvable maze to the HVAC engineer asked to upgrade adsorbent testing requirements following the standards. This paper describes the authors experience with a number of nuclear power facilities in their efforts to meet the requirements of the new standards of testing adsorbents from nuclear power plant air cleaning systems. The existing standards are discussed in light of the current state of the art for adsorbent testing of adsorbent media from nuclear air treatment systems. Test results are presented showing the impact of new test requirements on acceptance criteria when compared to the old test requirements and recommendations are offered for solution of this testing problem in the future. 12 refs., 5 tabs

  12. 77 FR 14343 - Announcement of the American Petroleum Institute's Standards Activities

    Science.gov (United States)

    2012-03-09

    ... Welding Ends, 7th Edition. Standard 603, Corrosion-Resistant, Bolted Bonnet Gate Valves-- Flanged and Butt... Practice 756, Management of Hazards Associated with Location of Process Plant Tents and Fabric Structures....org/meetings/ for more information regarding participation in these meetings. Safety and Fire...

  13. 78 FR 16538 - Agency Information Collection Activities; Submission for OMB Review; Comment Request; Standard on...

    Science.gov (United States)

    2013-03-15

    ... (OSHA) sponsored information collection request (ICR) titled, ``Standard on 4,4'-Methylenedianiline in... this request to the Office of Information and Regulatory Affairs, Attn: OMB Desk Officer for DOL-OSHA...'-Methylenedianiline (MDA) in Construction protects workers from adverse health effects associated with occupational...

  14. 75 FR 75573 - Standards Governing the Release of a Suspicious Activity Report

    Science.gov (United States)

    2010-12-03

    ... Part III Department of the Treasury Comptroller of the Currency 12 CFR Parts 4 and 21 Office of Thrift Supervision 12 CFR Parts 510 and 563 31 CFR Part 103 Standards Governing the Release of a... THE TREASURY Office of the Comptroller of the Currency 12 CFR Part 4 [Docket ID OCC-2010-0018] RIN...

  15. 30 CFR 942.816 - Performance standards-Surface mining activities.

    Science.gov (United States)

    2010-07-01

    ...: (1) Channel lining shall be designed using standard engineering practices to pass safely the design... specified in the approved reclamation plan. To minimize competition with woody plants, herbaceous ground... compacted fill to a minimum depth of one foot. (2) Ancillary Roads. (i) Field design methods may be utilized...

  16. 30 CFR 942.817 - Performance standards-Underground mining activities.

    Science.gov (United States)

    2010-07-01

    ...: (1) Channel lining shall be designed using standards engineering practices to pass safely the design... at least equal to the rates specified in the approved reclamation plan. To minimize competition with...) Culverts shall be covered by compacted fill to a minimum depth of one foot. (2) Ancillary roads. (i) Field...

  17. 75 FR 35286 - Agency Information Collection Activities; Proposed Collection; Comment Request; Safety Standard...

    Science.gov (United States)

    2010-06-21

    ... the retail package. There are seven known firms supplying walkers to the United States market. Four of... instructional literature requirements in the Safety Standard for Infant walkers. DATES: Submit written or... for marking and instructional literature. We estimate the burden of this collection of information as...

  18. 75 FR 30783 - Agency Information Collection Activities; Proposed Collection; Comment Request; Safety Standard...

    Science.gov (United States)

    2010-06-02

    ... product and the retail package. There are three known firms supplying bath seats to the United States... marking and instructional literature requirements in the Safety Standard for Infant Bath Seats. DATES... for marking and instructional literature. We estimate the burden of this collection of information as...

  19. 78 FR 37404 - Small Business Size Standards: Support Activities for Mining

    Science.gov (United States)

    2013-06-20

    ... assistance programs, SBA establishes small business size definitions (referred to as size standards) for... million should be the limit of a small business definition and anything larger than that, such as that SBA... Business Act (15 U.S.C. 632(a)) (Act) requires that small business size definitions vary to reflect...

  20. 77 FR 72766 - Small Business Size Standards: Support Activities for Mining

    Science.gov (United States)

    2012-12-06

    ... eligibility for Federal small business assistance, SBA establishes small business size definitions (referred... operation; and (3) within a specific small business definition or size standard established by SBA... to SBA's Administrator the responsibility for establishing small business definitions. The Act also...

  1. 78 FR 12037 - Announcement of the American Petroleum Institute's Standards Activities

    Science.gov (United States)

    2013-02-21

    ... Execution, 1st Edition Standard 2CCU, Offshore Cargo Container Design, Manufacturing and Inspection, 1st... Integrity Management of Fixed Offshore Structures, 1st Edition Recommended Practice 2SM, Design, Manufacture... Offshore Production Platforms, 8th Edition Specification 14F, Design and Installation of Electrical Systems...

  2. 75 FR 8039 - Announcement of the American Petroleum Institute's Standards Activities

    Science.gov (United States)

    2010-02-23

    ...: RP 10B-6, Recommended Practice on Determining the Static Gel Strength of Cement Formulations, 1st Ed... Transportation of Line Pipe, 1st Ed. Spec 10A, Specification for Cements and Materials for Well Cementing, 24th..., Standard Test Method for Density, Relative Density (Specific Gravity), or API Gravity of Crude Petroleum...

  3. Examining English Language Arts Common Core State Standards Instruction through Cultural Historical Activity Theory

    Science.gov (United States)

    Barrett-Tatum, Jennifer

    2015-01-01

    The English Language Arts Common Core State Standards and corresponding assessments brought about many changes for educators, their literacy instruction, and the literacy learning of their students. This study examined the day-to-day literacy instruction of two primary grade teachers during their first year of full CCSS implementation. Engestr?m's…

  4. Overview and comparative study of GPR international standards and guidelines - COST Action TU1208

    Science.gov (United States)

    Pajewski, Lara; Marciniak, Marian; Benedetto, Andrea; Tosti, Fabio

    2016-04-01

    for Determining the Thickness of Bound Pavement Layers Using Short-Pulse Radar, ASTM International, West Conshohocken, PA, 2010, www.astm.org, DOI: 10.1520/D4748-10. Further ASTM standards exist, not focused on GPR but including useful information (details are not provided here, for brevity reasons). There are no standards in Europe, instead, guiding the GPR use for subsurface prospecting and regulating the numerous applications of this non-destructive technique. The following Radio and Telecommunications Terminal Equipment (R&TTE) directive applies to GPR equipment and allows the placing of a GPR product on the European (EU) market for sale: Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999, on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity. Official Journal of the European Union, L 91, 7.4.1999, open access on ec.europa.eu. This document will be repealed, since 13 June 2016, by the following R&TTE directive: Directive 2014/53/EU of the European Parliament and of the Council of 16 April 2014, on the harmonisation of the laws of the Member States relating to the making available on the market of radio equipment, repealing Directive 1999/5/EC. Official Journal of the European Union, L 153, 22.5.2014, open access on ec.europa. Although conformance to the R&TTE directive allows the placing of a GPR product on the market for sale, it does not give authority for its use. In order to use the equipment, in the majority of EU member countries, a license is required. The license is controlled and issued by the radio administration in each of the member countries. The Electronic Communications Committee (ECC) of the European Conference of Postal and Telecommunications Administrations (CEPT) considers and develops policies on electronic communications activities in European context, taking account of European and international legislations and regulations. There are 48 European countries

  5. The effect of standard heat and filtration processing procedures on antimicrobial activity and hydrogen peroxide levels in honey.

    Science.gov (United States)

    Chen, Cuilan; Campbell, Leona T; Blair, Shona E; Carter, Dee A

    2012-01-01

    There is increasing interest in the antimicrobial properties of honey. In most honey types, antimicrobial activity is due to the generation of hydrogen peroxide (H(2)O(2)), but this can vary greatly among samples. Honey is a complex product and other components may modulate activity, which can be further affected by commercial processing procedures. In this study we examined honey derived from three native Australian floral sources that had previously been associated with H(2)O(2)-dependent activity. Antibacterial activity was seen in four red stringybark samples only, and ranged from 12 to 21.1% phenol equivalence against Staphylococcus aureus. Antifungal activity ranged from MIC values of 19-38.3% (w/v) against Candida albicans, and all samples were significantly more active than an osmotically equivalent sugar solution. All honey samples were provided unprocessed and following commercial processing. Processing was usually detrimental to antimicrobial activity, but occasionally the reverse was seen and activity increased. H(2)O(2) levels varied from 0 to 1017 μM, and although samples with no H(2)O(2) had little or no antimicrobial activity, some samples had relatively high H(2)O(2) levels yet no antimicrobial activity. In samples where H(2)O(2) was detected, the correlation with antibacterial activity was greater in the processed than in the unprocessed samples, suggesting other factors present in the honey influence this activity and are sensitive to heat treatment. Antifungal activity did not correlate with the level of H(2)O(2) in honey samples, and overall it appeared that H(2)O(2) alone was not sufficient to inhibit C. albicans. We conclude that floral source and H(2)O(2) levels are not reliable predictors of the antimicrobial activity of honey, which currently can only be assessed by standardized antimicrobial testing. Heat processing should be reduced where possible, and honey destined for medicinal use should be retested post-processing to ensure that

  6. Grazing incidence synchrotron X-ray diffraction and Moessbauer spectroscopy analyses of plasma nitrided ASTM F138 stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Danilo Olzon Dionysio de; Ardisson, Jose Domingos, E-mail: dolzon@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Silva, Edilaine Honorio [Studiecentrum voor Kernenergie (Belgium); Olzon-Dionysio, Maristela; Souza, Sylvio Dionysio de; Fabris, Jose Domingos [Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM), Diamantina, MG (Brazil); Martinez, L.G. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2016-07-01

    Full text: systematic investigation of samples of plasma-nitriding austenitic stainless steels ASTM F138 and AISI 316L is reported. The surface treatment of the steels through plasma-nitriding was used to improve further the hardness, wear and corrosion resistance of these stainless steels. The resulting layered crystallographic structure actually corresponds to several phases with close cell parameters, making their identification and quantification a real experimental challenge. The ASTM F138 and AISI 316L stainless steel disks were plasma nitrided for 4 h at 400 deg C in a 80% H{sub 2} -20% N2 atmosphere at 6 torr, using plasma current frequencies between 6 and 100 kHz. Data of Moessbauer (CEMS and CXMS) and grazing incidence synchrotron X-ray diffraction (XRD-SR) were systematically collected. The nitrided layer thickness were not in general influenced by the plasma frequency, except at 12 kHz, which produced a layer thickness of approximately 8.0 mm, being in average 40% thicker than for the other samples. CXMS and CEMS Moessbauer spectra for this 12 kHz-sample show a much more pronounced magnetic resonance lines than for the other samples. The Fe{sub 4}N phase presents a single magnetic hyperfine interaction; the other two (Fe{sub 2-3}N and the expanded austenite) present both paramagnetic and magnetic components, even though their hyperfine parameters may not be safely separated. We also present the results of XRD-SR that were probed at several depths. The data from these techniques may be consistently correlated and this leads to an improved model to explain the structure of the nitrided layers. (author)

  7. 16 CFR 1031.7 - Commission support of voluntary standards activities.

    Science.gov (United States)

    2010-01-01

    ... government or industrial model code development activities, so as to develop uniformity and minimize... as hosting meetings and secretarial assistance. (11) Providing funding support for voluntary...

  8. Review and Outlook of China Electronic and IT Industry Footprints in IEC International Standardization Activities

    Institute of Scientific and Technical Information of China (English)

    Hu Jingping

    2006-01-01

    @@ Year 2006 is the year marking the 100th anniversary of the founding of International Electrotechnical Commission (IEC). IEC is mainly engaged in the international standardization for electrical and electronic technology field aiming at promoting international trade and technology cooperation and exchange, improving product and service quality, upgrading productivity and protecting the environment as well as human health and safety. Most countries worldwide adopt standards developed and promulgated by IEC, providing a platform to international trade and technical exchange. China has being a member since 1957. Electronic and IT are the most developed and energetic filed in recent decades. Number of IEC TC/SC specialized in electronic and IT amounts up to 52.

  9. Role of hydrogen ions in standard and activation heap leaching of gold

    Science.gov (United States)

    Rubtsov, YuI

    2017-02-01

    The role of hydrogen ions in activation heap leaching of gold from rebellious ore has been studied, which has allowed enhancing gold recovery. The author puts forward a gold leaching circuit with the use of activated oxygen-saturated solutions acidified to pH = 6-9.

  10. Studying of the standardization principles of pharmacological activity of recombinant erythropoietin preparations

    OpenAIRE

    A. K. Yakovlev; L. A. Gayderova; N. A. Alpatova; T. N. Lobanova; E. L. Postnova; E. I. Yurchikova; T. A. Batuashvili; R. A. Volkova; V. N. Podkuiko; Yu. V. Olefir

    2016-01-01

    Analysis of the publications devoted to the structure, functions, mechanism of action of erythropoietin is given in the article. Erythropoietin preparations derived from recombinant DNA technology are a mixture of isoforms with different biological activity, which determine the biological properties pharmacological activity, pharmacokinetics, efficacy and safety of medicinal product. Erythropoietin preparations derived by using recombinant DNA technology are a mixture of isoforms with differe...

  11. University Students Meeting the Recommended Standards of Physical Activity and Body Mass Index

    Science.gov (United States)

    Deng, Xiaofen; Castelli, Darla; Castro-Pinero, Jose; Guan, Hongwei

    2011-01-01

    This study investigated student physical activity (PA) and body mass index (BMI) in relation to the "Healthy Campus 2010" objectives set by the American College Health Association in 2002. Students (N = 1125) at a U.S. southern state university participated in the study. The percentages of students who were physically active and whose…

  12. Electroluminescent TCC, C3dg and fB/Bb epitope assays for profiling complement cascade activation in vitro using an activated complement serum calibration standard.

    Science.gov (United States)

    van Vuuren, B Jansen; Bergseth, G; Mollnes, T E; Shaw, A M

    2014-01-15

    Electroluminescent assays for epitopes on the complement components C3dg, terminal complement complex (TCC) and factor B/Bb (fB/Bb) have been developed with capture and detection antibodies to produce detection limits C3dg=91±9ng/mL, TCC=3±0.1ng/mL and fB=55.7±0.1ng/mL. The assay performance was assessed against a series of zymosan and heat aggregated IgG (HAIgG) in vitro activations of complement using a calibrated activated complement serum (ACS) as calibration standard. The ACS standard was stable within 20% accuracy over a 6-month period with freeze-thaw cycles as required. Differential activation of the complement cascade was observed for TCC showing a pseudo-first order formation half-life of 3.5h after activation with zymosan. The C3dg activation fragment indicates a 10% total activation for both activation agents. The kinetic-epitope analysis for fB indicates that the capture epitope is on the fB/Bb protein fragment which can then become covered by the formation of C3bBb or C3bBbP complexes during the time course of the cascade. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. 77 FR 56809 - Certain Small Diameter Seamless Carbon and Alloy Steel Standard, Line, and Pressure Pipe From...

    Science.gov (United States)

    2012-09-14

    ... stress levels. Alloy pipes made to ASTM standard A-335 must be used if temperatures and stress levels... not used in standard, line or pressure applications. In addition, finished and unfinished oil country... antidumping duty order from the same country. If not covered by such an OCTG order, finished and unfinished...

  14. Comparison of Kayzero for Windows and k0-IAEA software packages for k0 standardization in neutron activation analysis

    Czech Academy of Sciences Publication Activity Database

    Kubešová, Marie; Kučera, Jan

    2011-01-01

    Roč. 654, č. 1 (2011), s. 206-212 ISSN 0168-9002 R&D Projects: GA ČR GA202/09/0363 Institutional research plan: CEZ:AV0Z10480505 Keywords : neutron activation analysis * ko standardization * Kayzero for Windows program * ko-IAEA program Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.207, year: 2011

  15. A study of the feasibility of using standards of performance funding to support investment in active solar heating systems

    International Nuclear Information System (INIS)

    1999-01-01

    This report summarises the results of studies examining the feasibility of starting Standards of Performance (SOP) programmes to support investment in solar heating systems and develop tools for helping the implementation of the programmes. The background to the project is traced, and the scope for an active solar heating SOP scheme, the market potential for the SOP schemes in Great Britain, and the purchasing of the associated hardware within the SOP scheme are examined. (UK)

  16. New standards for digital radiography and qualification of detectors; Neue Standards zur Digitalen Radiographie und Qualifizierung von Detektoren

    Energy Technology Data Exchange (ETDEWEB)

    Ewert, Uwe; Zscherpel, Uwe [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany)

    2017-08-01

    The contribution describes the most important standards for radiographic examinations that are revised in different committees. Information is given on new requirements esp. on revised parameters that have to be considered in practical testing procedures and classification. Actually for the revision of ISO 17636-1/2 in 2018 user questions are collected concerning weld seam testing. The DIN 25435 standards for weld seam testing in nuclear technology have been translated into English. Revisions of ASTM standards have to be considered in the actual EN and ISO standards. Since several years the International Institute of Welding (IIW) is also revising the international standards.

  17. Time and Frequency Activities at the Lithuanian National Time Standard Laboratory

    National Research Council Canada - National Science Library

    Miskinis, Rimantas

    2007-01-01

    ...), the Datum 2001 and SyncServer S250 NTP servers are used. Laboratory activities on coordination of the BALTICTIME project Reinforcing e-Government services in Baltic States through legal and accountable Digital Time Stamps...

  18. Effect of increased fuel temperature on emissions of oxides of nitrogen from a gas turbine combustor burning ASTM jet-A fuel

    Science.gov (United States)

    Marchionna, N. R.

    1974-01-01

    An annular gas turbine combustor was tested with heated ASTM Jet-A fuel to determine the effect of increased fuel temperature on the formation of oxides of nitrogen. Fuel temperature ranged from ambient to 700 K. The NOx emission index increased at a rate of 6 percent per 100 K increase in fuel temperature.

  19. Spontaneous ignition in afterburner segment tests at an inlet temperature of 1240 K and a pressure of 1 atmosphere with ASTM jet-A fuel

    Science.gov (United States)

    Schultz, D. F.; Branstetter, J. R.

    1973-01-01

    A brief testing program was undertaken to determine if spontaneous ignition and stable combustion could be obtained in a jet engine afterburning operating with an inlet temperature of 1240 K and a pressure of 1 atmosphere with ASTM Jet-A fuel. Spontaneous ignition with 100-percent combustion efficiency and stable burning was obtained using water-cooled fuel spraybars as flameholders.

  20. Automation of the ANSTO working standard of measurement for the activity of radionuclides

    International Nuclear Information System (INIS)

    Buckman, S.M.

    1990-08-01

    The ANSTO working standard ion chamber is used routinely for the standardisation of a range of gamma emitting radio-isotopes. The ion chamber has recently been automated by replacing the AAEC type 292 Recycling Discriminator, timer module and model 43 teletype printer with the HP86B computer, HP-59501B voltage programmer and HP-6181C current source. The program 'MEASION', running on the Deltacom IBM AT clone, calculates the radioactivity, with full error statements, from the ion chamber measurements. Each of these programs is listed and discussed. 13 refs., 5 figs., tabs

  1. Etalon (standard) for surface potential distribution produced by electric activity of the heart.

    Science.gov (United States)

    Szathmáry, V; Ruttkay-Nedecký, I

    1981-01-01

    The authors submit etalon (standard) equipotential maps as an aid in the evaluation of maps of surface potential distributions in living subjects. They were obtained by measuring potentials on the surface of an electrolytic tank shaped like the thorax. The individual etalon maps were determined in such a way that the parameters of the physical dipole forming the source of the electric field in the tank corresponded to the mean vectorcardiographic parameters measured in a healthy population sample. The technique also allows a quantitative estimate of the degree of non-dipolarity of the heart as the source of the electric field.

  2. Evaluation of Cholesterol-lowering Activity of Standardized Extract of Mangifera indica in Albino Wistar Rats.

    Science.gov (United States)

    Gururaja, G M; Mundkinajeddu, Deepak; Kumar, A Senthil; Dethe, Shekhar Michael; Allan, J Joshua; Agarwal, Amit

    2017-01-01

    Cholesterol lowering activity of Mangifera indica L. has been determined by earlier researchers and kernel, leaf and bark have shown significant activity. However, the specific cholesterol lowering activity of leaf methanol extract has not been determined. The present study involved evaluation of cholesterol lowering potential of methanol extract of M. indica leaves using high cholesterol diet model in albino Wistar rats. The acute oral toxicity at a dose of 5000 mg/ kg body weight was also determined in female albino Wistar rats. Phytoconstituents Iriflophenone 3-C-β-D-glucoside and mangiferin were quantified in methanol extracts of different varieties of mango leaves using high performance liquid chromatography. Significant cholesterol lowering activity was observed with methanol extract of M. indica leaves, at dose of 90 mg/kg body weight in rats and it was also found to be safe at dose of 5000 mg/kg rat body. Iriflophenone 3-C-β-D-glucoside and mangiferin were found to be in the range of 1.2 to 2.8% w/w and 3.9 to 4.6% w/w, respectively which along with 3 β taraxerol and other sterols could be contributing to the cholesterol lowering activity of mango leaves extract. The phytosterols rich extract of Mangifera indica leaves is a good source of nutraceutical ingredient that have the potential to lower serum cholesterol levels. The Mangifera indica leaves methanolic extract showed significant cholesterol lowering activity in high cholesterol diet induced hypercholesterolaemia model in rats when evaluated at a dose of 90 mg/kg rat body weight. The extract was found to contain Iriflophenone 3-C-β-D-glucoside and mangiferin which along with 3 β taraxerol and other sterols could be contributing to the cholesterol lowering activity.

  3. Holmium-166m: multi-gamma standard to determine the activity of radionuclides in semiconductor detectors

    International Nuclear Information System (INIS)

    Bernardes, Estela Maria de Oliveira

    2001-01-01

    The efficiency and calibration curves as function of gamma-ray energy for a germanium detector are usually established by using many standard gamma ray sources of radionuclides decaying with few gamma rays or radionuclides having complex decay scheme, as 152 Eu or 133 Ba. But these radionuclides cannot be used alone, because they have a few gamma lines with high intensity and these lines have a irregular distribution in the energy spectrum. 166m Ho is found to be a convenient single source for such calibration, because it decays by β - with subsequent emission of about 40 strong and well distributed gamma lines between 80 and 1500 keV. Moreover, its long half - life (1200 years) and X-rays characteristics between 40 and 50 keV makes it a good standard for calibration of germanium detectors. However, it is necessary to know with accuracy and precision the gamma ray intensities of their main lines, due to the fact that literature has showed discrepant values. Then, a methodology to determine the emission probability of its main lines is proposed by means of combined use of gamma spectrometry and coincidence 4πβ -γ techniques. The experimental results show consistence to the others authors, with lower or compatible uncertainties. (author)

  4. Standard recommended practice for examination of fuel element cladding including the determination of the mechanical properties

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Guidelines are provided for the post-irradiation examination of fuel cladding and to achieve better correlation and interpretation of the data in the field of radiation effects. The recommended practice is applicable to metal cladding of all types of fuel elements. The tests cited are suitable for determining mechanical properties of the fuel elements cladding. Various ASTM standards and test methods are cited

  5. 77 FR 73354 - Safety Standard for Hand-Held Infant Carriers

    Science.gov (United States)

    2012-12-10

    .... Edwards, Project Manager, Directorate for Engineering Sciences, U.S. Consumer Product Safety Commission, 5..., allergic reactions and near- choking episodes are the most common injuries reported in the remaining 58... modification of the ASTM standard to address the requirements for flammability, surface chemicals, cords...

  6. 77 FR 70390 - Lifesaving Equipment: Production Testing and Harmonization With International Standards

    Science.gov (United States)

    2012-11-26

    ... components within the system to be made of corrosion-resistant materials without the need for galvanizing... resistant in the marine environment without the need for coatings or galvanizing,'' the current ASTM.... This standard would no longer be appropriate because these steels require coatings or galvanizing to be...

  7. 76 FR 55056 - Toy Safety Standard: Strategic Outreach and Education Plan

    Science.gov (United States)

    2011-09-06

    ... to test and certify to the toy safety standard. We plan to use traditional and social media to... testing and certification requirements for children's toys and toy chests and their compliance with ASTM... manufacturers of children's toys must ensure that covered toys are tested for compliance with the toy safety...

  8. A standardized evaluation of artifacts from metallic compounds during fast MR imaging

    DEFF Research Database (Denmark)

    Murakami, Shumei; Verdonschot, Rinus G; Kataoka, Miyoshi

    2016-01-01

    according to the ASTM-F2119 standard and artifact volumes were assessed using OsiriX MD software Results: Tukey-Kramer post-hoc tests were used for statistical comparisons. For most materials, scanning sequences eliciting artifact volumes in the following (ascending) order FSE-T1/FSE-T2

  9. Use of gold and silver standards based on phenol-formalde-hyde resin in assay-activation analysis of geological samples

    International Nuclear Information System (INIS)

    Aliev, A.I.; Drynkin, V.I.; Lejpunskaya, D.I.; Nedostup, T.V.

    1976-01-01

    Using standards on phenol-formaldehyde resin base for assaying-activation analysis of geological specimens for gold and silver has bee the advantage of uniformly distributing Au and Ag in spesimens and possible preparing tablets of practically any form or size. The validity and accuracy of these standards have been studied for the cases of short irradiation. Conventional point standards were used as reference standards. The experiments carried out have shown that tablet resol standards are suitable for a mass assaying-activation analysis for gold and silver at practically any concentrations

  10. A Delphi Study to Develop a Standard List of Activities that Comprise Routine Clinical Pharmacy Services

    Science.gov (United States)

    2012-06-08

    Denzin and Lincoln propose that “Qualitative research is a situated activity that locates the observer in the world. It consists of a set of......Publications, 2003. Davies, Martin Brett. Doing a Successful Research Project. New York: Palgrave Macmillan, 2007. Denzin , Norman K., and Yvonna S

  11. Training to Support Standardization and Improvement of Safety I and C Related Verification and Validation Activities

    Energy Technology Data Exchange (ETDEWEB)

    Ammon, G.; Schoenfelder, C.

    2014-07-01

    In recent years AREVA has conducted several measures to enhance the effectiveness of safety I and C related verification and validation activities within nuclear power plant (NPP) new build as well as modernization projects, thereby further strengthening its commitment to achieving the highest level of safety in nuclear facilities. (Author)

  12. Analysis of interoperability requirements and of relevant activities in standards bodies and fora

    DEFF Research Database (Denmark)

    Guarneri, R.; Skouby, Knud Erik; Falch, Morten

    1999-01-01

    The aim of this deliverable is to provide the summary of the standardisation activities considered of most relevance for the work of the PRIME project with respect to interoperability; this information is of prime importance for the planning of further PRIME technical work in this area....

  13. Evaluation of muscle activity during a standardized shoulder resistance training bout in novice individuals

    DEFF Research Database (Denmark)

    Jakobsen, Markus D; Sundstrup, Emil; Andersen, Christoffer H

    2012-01-01

    training bout. The purpose of this study was to evaluate muscle activity during a shoulder resistance training bout with 15 repetitions maximum (RM) loadings in novice individuals. Twelve healthy sedentary women (age = 27-58 years; weight = 54-85 kg; height = 160-178 cm) were recruited for this study...

  14. A data base and a standard material for use in acceptance testing of low-activity waste products

    International Nuclear Information System (INIS)

    Wolf, S.F.; Ebert, W.L.; Luo, J.S.; Strachan, D.M.

    1998-04-01

    The authors have conducted replicate dissolution tests following the product consistency test (PCT) procedure to measure the mean and standard deviation of the solution concentrations of B, Na, and Si at various combinations of temperature, duration, and glass/water mass ratio. Tests were conducted with a glass formulated to be compositionally similar to low-activity waste products anticipated for Hanford to evaluate the adequacy of test methods that have been designated in privatization contracts for use in product acceptance. An important finding from this set of tests is that the solution concentrations generated in tests at 20 C will likely be too low to measure the dissolution rates of waste products reliably. Based on these results, the authors recommend that the acceptance test be conducted at 40 C. Tests at 40 C generated higher solution concentrations, were more easily conducted, and the measured rates were easily related to those at 20 C. Replicate measurements of other glass properties were made to evaluate the possible use of LRM-1 as a standard material. These include its composition, homogeneity, density, compressive strength, the Na leachability index with the ANSI/ANS 16.1 leach test, and if the glass is characteristically hazardous with the toxicity characteristic leach procedure. The values of these properties were within the acceptable limits identified for Hanford low-activity waste products. The reproducibility of replicate tests and analyses indicates that the glass would be a suitable standard material

  15. Interim technical evaluation report of testing procedures for activated carbon adsorbers in ventilation filter assemblies in nuclear power plants

    International Nuclear Information System (INIS)

    Sill, C.W.; Scarpellino, C.D.; Tkachyk, J.W.; Grey, A.E.; Frank, C.W.

    1985-05-01

    Laboratory analysis of activated carbon is required by nuclear power plant technical specifications for use in Engineered Safety Feature (ESF) ventilation systems to determine the capability of those systems to remove radioiodines from air during normal operation and following a design basis accident (DBA). The lask of agreement of laboratory results from a recent round robin raised concerns regarding the adequacy of the analyses, using the ASTM D3803-79 standard, to assure compliance with plant technical specifications. EG and G Idaho was contracted by the NRC to conduct a program to provide the bases for resolving these concerns. This EG and G report serves as an interim Technical Evaluation Report (TER) of the program and presents reviews of the ASTM D3803-79 standard and the commercial testing laboratories. Results of EG and G laboratory studies and the NRC/EG and G Interlaboratory Comparison are presented with conclusions and recommendations concerning changes required to improve the standard and its application. Possible revisions to plant technical specifications required to reflect the true capability of activated carbon to remove radioiodines are also presented

  16. THE IMPACT OF PENSIONS SAVING AND EDUCATION DEFICIT ON THE LIVING STANDARDS IN ROMANIA, IN THE POST-ACTIVITY PERIOD

    Directory of Open Access Journals (Sweden)

    SANDRA TEODORESCU

    2011-04-01

    Full Text Available The present paper starts with the study on the annual pension deficit in the EU member states, elaborated by AVIVA and DELOITTE companies in 2010. The paper analyzes the impact of pensions saving and education deficit on the living standards in Romania, in the post-activity period. It comprises the following sections: an introduction to the analysis, several definitions and the calculation method employed in the above-mentioned study, comparisons between Romania and other EU members states, focusing on the pension deficit, as well as a brief overview on the pension systems in Romania. In the end of the paper, we propose a debate on good financial planning that can make the difference between poverty and a decent standard of living at the time of retirement.

  17. Design and construction of a cryogenic facility providing absolute measurements of radon 222 activity for developing a primary standard

    International Nuclear Information System (INIS)

    Picolo, Jean-Louis

    1995-06-01

    Radon 222 metrology is required to obtain higher accuracy in assessing human health risks from exposure to natural radiation. This paper describes the development of a cryogenic facility that allows absolute measurements of radon 222 in order to obtain a primary standard. The method selected is the condensation of a radon 222 sample on a geometrically defined cold surface with a constant, well known and adjustable temperature and facing an alpha particles detector. Counting of the alpha particles reaching the detector and the precisely known detection geometry provide an absolute measurement of the source activity. After describing the cryogenic facility, the measurement accuracy and precision are discussed and a comparison made with other measurement systems. The relative uncertainty is below 1 pc (1 σ). The facility can also be used to improve our knowledge of the nuclear properties of radon 222 and to produce secondary standards. (author) [fr

  18. Phytochemical standardization and biological activities of certain desert plants growing in Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Muneera S. Al-Saleem

    2018-02-01

    Full Text Available The phytochemical screening, antimicrobial and antitumor activities of Calendula tripterocarpa, Centarea sinaica, Centaurea pseudosinaica, Koelpinia linearis, Plectranthus arabicus, Plectranthus asirensis and Tripleurospermum auriculatum determined. The best antibacterial activity; 41.8 ± 0.23 mm, 39.7 ± 0.25 mm, 35.8 ± 0.58 mm, 34.7 ± 0.51 mm and 32.7 ± 0.25 mm was obtained by Plectranthus arabicus against Klebsiella pneumonia, Tripleurospermum auriculatum against Bacillus subtilis, Centaurea pseudosinaica against Bacillus subtilis, Centaurea pseudosinaica against Stroptococcus pyogenes and Plectranthus arabicus against Staphylococcus epidermidis, respectively. While the highest antifungal activity; 35.9 ± 1.15 mm, 34.6 ± 0.34, 30.6 ± 0.26 mm and 29.9 ± 0.63 mm was obtained by Tripleurospermum auriculatum against Geotricum candidum, Candida albicans, C. tropicalis and Aspergillus fumigatus, respectively. The antitumor activity (IC50 obtained by Centarea sinaica; 3.1 ± 6.9 µg/ml, 14.3 ± 3.1 µg/ml and 22.7 ± 4.1 µg/ml was better than activity of vinblastine sulphate; 5.9 ± 0.4 µg/ml, 59.7 ± 2.1 µg/ml and 30.3 ± 1.4 µg/ml against breast carcinoma (MCF-7, cervical carcinoma (Hela and colorectal carcinoma (CACO, respectively. Plectranthus arabicus alcoholic extract showed higher antitumor activity; 15.3 ± 5.3 µg/ml, 28.6 ± 3.6 µg/ml and 24.3 ± 4.1 µg/ml than vinblastine; 21.2 ± 0.9 µg/ml, 59.7 ± 2.1 µg/ml and 30.3 ± 1.4 µg/ml against prostate carcinoma (Pc3, cervical carcinoma (Hela and colorectal carcinoma (CACO, respectively. Also, the antitumor activity of Plectranthus asirensis against cervical carcinoma (Hela (37.1 ± 2.6 µg/ml was potent than vinblastine sulphate (59.7 ± 2.1 µg/ml. The obtained results of LD50 and sub-chronic toxicity revealed that the plants have no

  19. Nanotechnology Standardization Activities – Support of U.S. Representation on ISO/TC 229 Nanotechnologies

    Energy Technology Data Exchange (ETDEWEB)

    Benko, Heather [American National Standards Inst. (ANSI), Washington, DC (United States)

    2017-03-14

    In carrying out its responsibilities on behalf of the United States, ANSI provides comprehensive, administrative support and expertise on international protocols and procedures to: (1) the U.S. Technical Advisory Group (TAG) to the International Organization for Standardization’s (ISO) Technical Committee (TC) 229 Nanotechnologies, and (2) the corresponding U.S. TAG Working Groups tasked with formulating U.S. positions on topics relevant to nanotechnology standardization. Additionally, secretariat and procedural support is provided for the ISO/TC 229 WG 3 on health, safety and environment, for which the United States was assigned leadership by the participating national body members of ISO/TC 229. As the official entity that serves as the U.S. representative to ISO, ANSI provides not only expert coordination of U.S. positions and representation at ISO but also strategic direction, advice and procedural expertise to facilitate navigation of international issues to promote U.S. positions for incorporation into the ISO/TC 229 program of work necessary to support U.S. objectives.

  20. Determination of radioisotopic contents of high-active materials in non-standard conditions

    International Nuclear Information System (INIS)

    Klupak, V.; Viererbl, L.; Lahodova, Z.; Vins, M.

    2014-01-01

    The light-water research reactor LVR-15, operated by Research |Centre Rez, serves as a source of neutrons for applied and basic research. One of the main areas of applied research is the influence of neutron radiation field on the physical and mechanical properties of construction materials used in reactor technology. The presented contribution deals with the determination of a radioisotopic composition and the estimate of its activity.The determination is based on gamma spectrometry measurements. The purpose of the measurements was the determination of the main sources of radiation and the result was used to prepare a procedure for the handling, transport and testing of samples in the rigs. (authors)

  1. High sensitivity neutron activation analysis of environmental and biological standard reference materials

    International Nuclear Information System (INIS)

    Greenberg, R.R.; Fleming, R.F.; Zeisler, R.

    1984-01-01

    Neutron activation analysis is a sensitive method with unique capabilities for the analysis of environmental and biological samples. Since it is based upon the nuclear properties of the elements, it does not suffer from many of the chemical effects that plague other methods of analysis. Analyses can be performed either with no chemical treatment of the sample (instrumentally), or with separations of the elements of interest after neutron irradiation (radiochemically). Typical examples of both types of analysis are discussed, and data obtained for a number of environmental and biological SRMs are presented. (author)

  2. Regulations, guidelines, standards, and policies pertaining to decontamination and decommissioning activities: A literature review. Informal report, Revision 1

    International Nuclear Information System (INIS)

    Cowgill, M.G.

    1994-09-01

    A literature review of the existing rules, regulations, and guidelines pertaining to the decontamination and decommissioning of nuclear facilities has been updated. Included in the survey are US Government documents, national (industrial) standards, international standards and guidelines, and the regulations issued by various national governments, such as the United Kingdom, Canada, and Germany. The Department of Energy (DOE) complex contains within it almost 1,000 nuclear facilities which will require decommissioning in the coming years. This action will entail activities in many different areas, one of which will involve the development of the basic safety principles to be applied to the process as a whole. These principles will be used to guide personnel in the development of safety assessment procedures for decontamination and decommissioning (D and D) activities and in conducting safety assessments of such activities at the facilities themselves. The present report represents an updating of the original report. It retains all the information that appeared in the original report with the new material integrated into the applicable sections. Future revisions will be made as additional information becomes available

  3. Defense Standardization Program Journal. April/June 2011

    Science.gov (United States)

    2011-06-01

    years, the seven winners have played an integral part in keeping our men and women in uniform sate and in providing them the tools they need to get...supporting our men and women in uniform, helping to multiply capability through interoperability, and saving money tor the taxpayer. 1 hope that reading...committee chair of ASTM B687, "Standard Specifi- cation for Brass, Copper, and Chromium-Plated Pipe Nipples " (FSC 4730), to incor- porate eight additional

  4. Abnormal brain activation and connectivity to standardized disorder-related visual scenes in social anxiety disorder.

    Science.gov (United States)

    Heitmann, Carina Yvonne; Feldker, Katharina; Neumeister, Paula; Zepp, Britta Maria; Peterburs, Jutta; Zwitserlood, Pienie; Straube, Thomas

    2016-04-01

    Our understanding of altered emotional processing in social anxiety disorder (SAD) is hampered by a heterogeneity of findings, which is probably due to the vastly different methods and materials used so far. This is why the present functional magnetic resonance imaging (fMRI) study investigated immediate disorder-related threat processing in 30 SAD patients and 30 healthy controls (HC) with a novel, standardized set of highly ecologically valid, disorder-related complex visual scenes. SAD patients rated disorder-related as compared with neutral scenes as more unpleasant, arousing and anxiety-inducing than HC. On the neural level, disorder-related as compared with neutral scenes evoked differential responses in SAD patients in a widespread emotion processing network including (para-)limbic structures (e.g. amygdala, insula, thalamus, globus pallidus) and cortical regions (e.g. dorsomedial prefrontal cortex (dmPFC), posterior cingulate cortex (PCC), and precuneus). Functional connectivity analysis yielded an altered interplay between PCC/precuneus and paralimbic (insula) as well as cortical regions (dmPFC, precuneus) in SAD patients, which emphasizes a central role for PCC/precuneus in disorder-related scene processing. Hyperconnectivity of globus pallidus with amygdala, anterior cingulate cortex (ACC) and medial prefrontal cortex (mPFC) additionally underlines the relevance of this region in socially anxious threat processing. Our findings stress the importance of specific disorder-related stimuli for the investigation of altered emotion processing in SAD. Disorder-related threat processing in SAD reveals anomalies at multiple stages of emotion processing which may be linked to increased anxiety and to dysfunctionally elevated levels of self-referential processing reported in previous studies. © 2016 Wiley Periodicals, Inc.

  5. The preparation and measurement of activity for 57Co standard solution

    International Nuclear Information System (INIS)

    Yang Jingxia; Yu Yiguang; Du Hongshan; Chen Xilin

    1994-12-01

    In the preparation of 57 Co, the reactions of 56 Fe (d, n) 57 Co and 56 Fe(d,2n) 57 Co were selected by using 8.7 MeV deuteron to radiate natural iron which was electroplated on copper target. The methods of TBP-Benzene extraction and cation exchange were used for separating and purifying 57 Co. The purity of the solution was checked by HPGe γ spectrometer and the total contents of γ impurities were below 0.2%. To prepare the source, silicon gel suspension was electrosprayed on VYNS thin film which was metallized by gold to form a proper source pad. Weighing balance was used to quantitatively prepare the sources. Research on the effects of the working gas pressure and the working voltage on the plateau curve was carried on by the pressurized 4 πβ-γ coincidence equipment. Finally, efficiency extrapolation method was used to accurately measure the specific activity of 57 Co solution by means of changing the discrimination threshold. The total uncertainty is about 1.2%(3σ) . It is shown that the solution is uniform, stable and accuracy with the reliable specific activity through the domestic comparison. (6 figs.; 6 tabs.)

  6. Double standards for community sports: promoting active lifestyles but unhealthy diets.

    Science.gov (United States)

    Kelly, Bridget; Chapman, Kathy; King, Lesley; Hardy, Louise; Farrell, Louise

    2008-12-01

    Overweight and obesity in Australia is an emerging health concern. Obesity prevention initiatives must consider both physical activity and nutrition to be effective. Community sports venues have the capacity to promote healthy lifestyles through physical activity as well as healthy food choices. A telephone survey was conducted on parents of children aged 5-17 years in NSW to determine the nature of food and beverages purchased by children at community sporting venues and to determine parent's perception of the role that government should play in regulating the types of food and beverages sold at these outlets. The majority of canteens at children's sporting venues were considered to sell mostly unhealthy food and beverages (53%). Very few parents reported that canteens sold mostly healthy food and beverages. Parents reported that their child's most frequently purchased food and beverage items at outdoor sports fields were water, chocolate and confectionery, soft drink and sports drinks, and ice cream. At community swimming pools the most frequently purchased items were ice cream, followed by snack foods, including chips, cakes and biscuits. Most parents (63%) agreed that government should restrict the types of food and beverages that can be sold at children's sporting venues. Children are receiving inconsistent health messages at sporting venues, with healthy lifestyles being promoted through sports participation, but unhealthy dietary choices being provided at sports canteens.

  7. The standardisation of trace elements in international biological standard reference materials with neutron activation analysis and atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Pieterse, H.

    1981-12-01

    An investigation was undertaken into the analytical procedures and the identification of problem areas, for the certification of a new biological standard reference material supplied by the International Atomic Energy Agency, namely, a human hair sample designated as HH-I. The analyses comprised the determination of the elements As, Cd, Co, Cr, Cu, Fe, Hg, Mn, Ni, Sb, Se, and Zn in the hair sample by using two analytical techniques, namely, Instrumental Neutron Activation Analysis and Atomic Absorption. Three other certified biological reference materials, namely, Orchard Leaves (ORCH-L), Sea Plant Material (SPM-I) and Copepod (MAA-I) were used as control standards. Determinations were made of the moisture content of the samples, using varying conditions of drying, and the necessary corrections were applied to all analytical results so that the final elemental values related to dry weight of samples. Attention was also given to the possible loss of specific elements during ashing of the samples prior to the actual instrumental analysis. The results obtained for the hair sample by the two techniques were in good agreement for the elements Co, Fe, Mn, and Zn, but did not agree for the elements Cr and Sb. As, Hg and Se could only be determined with Instrumental Neutron Activation Analysis, and Cd, Cu and Ni only with Atomic Absorption. Most of the results obtained for the three control standard reference materials were within the ranges specified for the individual elements in each sample. The analytical procedures used for determining Cd, Cr, Cu, Ni and Sb with Instrumental Neutron Activation Analysis and As, Cr, Sb and Se with Atomic Absorption, need further investigation. The measurement of the moisture content and the ashing of samples also require further investigation with a view to improving accuracy

  8. Oliveria decumbens essential oil: Chemical compositions and antimicrobial activity against the growth of some clinical and standard strains causing infection.

    Science.gov (United States)

    Alizadeh Behbahani, Behrooz; Tabatabaei Yazdi, Farideh; Vasiee, Alireza; Mortazavi, Seyed Ali

    2018-01-01

    Oliveria decumbens as a valuable medicinal plant is extensively used in traditional medicine. clinical and standard strains causing infection resistance to antimicrobial agents, is one of the important problems in medicine. The aim of this study was to investigate the antibacterial activities and phytochemical analysis of Oliveria decumbens essential oil on the growth of some clinical and standard strains causing infection (Pseudomonas aerogenes, Escherichia coli, Streptococcus pyogenes and Staphylococcus epidermidis). Oliveria decumbens essential oil composition was identified by gas chromatography/mass spectrometry. Phytochemical analysis (alkaloids, saponins, flavone and phenolic) essential oil of the Oliveria decumbens were appraised based on qualitative methods. Several methods (disk diffusion, minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC)) were used to appraise the antibacterial activity of the Oliveria decumbens essential oil. Thymol (28.45%) was the major compound of Oliveria decumbens essential oil. The total phenolics content (TPC) of the essential oil positively correlated with antioxidant activity (AA). The TPC and AA of Oliveria decumbens essential oil was equal to 92.45 ± 0.70 μg GAE/mg and 164.45 ± 1.20 μg/ml, respectively. The MIC of Oliveria decumbens essential oil ranged from 1 to 8 mg/ml depending on the type of bacteria (clinical and standard strains). The MBC of Oliveria decumbens essential oil varied from 1 mg/ml to 16 mg/ml. The smallest inhibition zone diameter (IZD) on different Oliveria decumbens essential oil concentrations on P. aeruginosa. Results indicate that Oliveria decumbens essential oil can prove to be an important source of AA and antibacterial and may be used for the treatment of infection diseases. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. THE STUDY OF ACTIVITY REGARDING THE PROCESSES QUALITY ACCORDING TO ISO STANDARD 9004-2.1

    Directory of Open Access Journals (Sweden)

    OANA Ioan – Pavel

    2016-05-01

    Full Text Available Among the activities regarding processes quality according to ISO 9004-2.1 there is one refering to planning to keep under control the processes, achieved by: documentation of current activities, development of documented work instructions, establishing checkpoints and quality inspection techniques, assess the potential effectiveness of technological processes. A first step in this direction represents the presentation of the general elements that contribute to insuring the quality of each stage of manufacturing processes, the data being possible to suit for individual cases. It shall be noted that in industrial practice these quality assurance measures are designed interdependent. Preventive control during the technological processes has an important role in improving the technological processes in textiles and also increasing the quality performance of products in order to improve production and creating a recognizable brand in the world market. Quality of products manufactured in textiles has a decisive role in the present, when facing with an excess of production in this domain and a special competition between firms in the world market. A company that wants to continue to exist and develop must regularly check the quality/satisfaction degree obtained for the products manufactured. The application of quality control system implies a reference system compared to what can be measured by which we obtain “the quality level required and expected.” The referential system can be formed in a set of performance indicators so we can say that a company continues to be competitive as far as it established and achieved a series of performance indicators and in addition it controls these indicators every day.

  10. Anti-cholinesterase activity of the standardized extract of Syzygium aromaticum L.

    Science.gov (United States)

    Dalai, Manoj K; Bhadra, Santanu; Chaudhary, Sushil K; Bandyopadhyay, Arun; Mukherjee, Pulok K

    2014-04-01

    Clove (Syzygium aromaticum) is a well-known culinary spice with strong aroma; contains a high amount of oil known as clove oil. The major phyto-constituent of the clove oil is eugenol. Clove and its oil possess various medicinal uses in indigenous medicine as an antiseptic, anti-oxidant, analgesic and neuroprotective properties. Thus, it draws much attention among researchers from pharmaceutical, food and cosmetic industries. The aim of the present study was to determine the anti-cholinesterase activity of the methanol extract of clove, its oil and eugenol. In vitro anti-cholinesterase activity of S. aromaticum was performed by a thin layer chromatography bio autography, 96 well micro titer plate and kinetic methods. Reverse phase high performance liquid chromatography (RP-HPLC) analysis was carried out to identify the biomarker compound eugenol in clove oil. Acetylcholinesterase (AChE) and butyrylcholinesterase (BChE) inhibition study revealed that eugenol possess better inhibition of the enzymes than extract and oil. Clove extract, its oil and eugenol showed better inhibition of AChE than BChE. Polyphenolic compound eugenol was detected through RP-HPLC analysis. The content of eugenol in essential oil was found to be 0.5 μg/ml. Kinetic analysis of the cholinesterase inhibition study of the extract; clove oil and eugenol have shown that they possess mixed type of inhibition for AChE and non-competitive type of inhibition for BChE. These results might be useful in explaining the effect of clove as anti-cholinesterase agent for the management of cognitive ailments like Alzheimer's disease.

  11. Sensitization Behavior of Type 409 Ferritic Stainless Steel: Confronting DL-EPR Test and Practice W of ASTM A763

    Science.gov (United States)

    Scalise, Taís Campos; de Oliveira, Mara Cristina Lopes; Sayeg, Isaac Jamil; Antunes, Renato Altobelli

    2014-06-01

    Stainless steels employed for manufacturing automotive exhaust systems must withstand severe thermal cycles, corrosive environment due to urea decomposition, and welding operations. AISI 409 ferritic stainless steel can be considered a low-cost alternative for this application. However, depending on the manufacturing conditions during welding cycles, this material can be sensitized due to the precipitation of chromium carbides at grain boundaries. In this work, the intergranular corrosion resistances of the AISI 409 ferritic stainless steel were evaluated after annealing at 300, 500, and 700 °C for 2, 4, and 6 h. Solution-annealed samples were also tested for comparison purposes. Two methodologies were used to assess the sensitization behavior of the 409 stainless steel samples: the first one was based on the ASTM A763 (practice W), while the second one was based on the double-loop electrochemical potentiodynamic reactivation test. It was possible to identify that the annealing treatment performed at 500 °C was more critical to the occurrence of intergranular corrosion.

  12. Effects of thermal treatments on protein adsorption of Co-Cr-Mo ASTM-F75 alloys.

    Science.gov (United States)

    Duncan, L A; Labeed, F H; Abel, M-L; Kamali, A; Watts, J F

    2011-06-01

    Post-manufacturing thermal treatments are commonly employed in the production of hip replacements to reduce shrinkage voids which can occur in cast components. Several studies have investigated the consequences of these treatments upon the alloy microstructure and tribological properties but none have determined if there are any biological ramifications. In this study the adsorption of proteins from foetal bovine serum (FBS) on three Co-Cr-Mo ASTM-F75 alloy samples with different metallurgical histories, has been studied as a function of protein concentration. Adsorption isotherms have been plotted using the surface concentration of nitrogen as a diagnostic of protein uptake as measured by X-ray photoelectron spectroscopy. The data was a good fit to the Langmuir adsorption isotherm up to the concentration at which critical protein saturation occurred. Differences in protein adsorption on each alloy have been observed. This suggests that development of the tissue/implant interface, although similar, may differ between as-cast (AC) and heat treated samples.

  13. The effect of water injection on nitric oxide emissions of a gas turbine combustor burning ASTM Jet-A fuel

    Science.gov (United States)

    Marchionna, N. R.; Diehl, L. A.; Trout, A. M.

    1973-01-01

    Tests were conducted to determine the effect of water injection on oxides of nitrogen (NOx) emissions of a full annular, ram induction gas turbine combustor burning ASTM Jet-A fuel. The combustor was operated at conditions simulating sea-level takeoff and cruise conditions. Water at ambient temperature was injected into the combustor primary zone at water-fuel ratios up to 2. At an inlet-air temperature of 589 K (600 F) water injection decreased the NOx emission index at a constant exponential rate: NOx = NOx (o) e to the -15 W/F power (where W/F is the water-fuel ratio and NOx(o) indicates the value with no injection). The effect of increasing combustor inlet-air temperature was to decrease the effect of the water injection. Other operating variables such as pressure and reference Mach number did not appear to significantly affect the percent reduction in NOx. Smoke emissions were found to decrease with increasing water injection.

  14. High-cycle notch sensitivity of alloy steel ASTM A743 CA6NM used in hydrogenator turbine components

    Directory of Open Access Journals (Sweden)

    José Alexander Araújo

    2010-10-01

    Full Text Available The presence of notches and other stress concentrations in turbine blades and other notch hydraulic components is a current problem in engineering. It causes a reduction of endurance limit of material. In that sense, specimens of the ASTM A743 CA6NM alloy steel using in several hydrogenator turbine components was tested. The specimens were tested under uniaxial fatigue loading with a load ratio equal to -1, and the considered stress concentration factors, Kt, values, calculated with respect to net area, were 1.55, 2.04 and 2.42. In order to determine the fatigue limit for such notch type, a reduction data method by Dixon and Mood, Staircase method was used. This approach is based on the assumed target distribution of the fatigue limit. For such geometry at least 8 specimens were tested. In addition, the Peterson and Neuber’s notch fatigue factor were compared through fatigue notch reduction factor, Kf, obtained from experimental data. According to results obtained it was possible to conclude that the tested material is less sensitive to notches than the prediction of the Peterson and Neuber’s empirical models.

  15. Evaluation and standardization of neutron activation analysis according to the K0 method in the RP-10 reactor

    International Nuclear Information System (INIS)

    Montoya R, E.

    1995-01-01

    It has been characterized and standardized an irradiation of the RP-10 Research Nuclear Reactor for use of the K 0 method of neutron activation analysis using the Hoegdahl convention; also it has been evaluate the behaviour of such method in regard to the accuracy and precision of the results obtained in the quantitative multi elemental analysis of several certified materials of reference. In order to prove that the analytical method is totally under statistical control, it has been used the Heydorn method. It has been verified that the method is exact, precise and reliable to determine the aluminium, antimuonium, arsenic, bromine, calcium, chloride, copper, magnesium, manganese, sodium, titanium, vanadium, zinc and other elements. Also, they are discussed, in regard to the use of K 0 constants, the different formalisms employed to calculate the integral of the reaction rate by nucleus in the activation. (author). 58 refs., 18 tabs., 6 figs

  16. Investigation of two slag samples using k0 neutron activation analysis through different standardization methods

    Directory of Open Access Journals (Sweden)

    M. Abd El-Samad

    2010-12-01

    Full Text Available Instrumental neutron activation analysis was used to determine concentrations of several major and trace elements in two slag samples. One slag supplied by one of Steel factory and the other one by an Aluminum factory of Egypt. The aim of the present work is to study the accuracy and precision of Internal Comparator k0 and external comparator k0 methods in industrial application. The two slag samples together with an international reference material Soil-7 and two thin gold foils samples (one bare and the other covered with cadmium were irradiated at the core of the Second Research Egyptian Reactor ET-RR-2 of about 13x10 13n/(cm s. The elemental concentration of 46Sc, 51Cr, 60Co, 65Zn, 74As, 82Br, 85Sr, 86Zr, 110mAg, 122Sb, 134Cs, 131Ba, 140La, 141Ce, 147Nd, 153Sm, 152Eu, 153Gd, 166Ho, 169Yb, 175Hf, 182Ta, 198Au and 233Pa (232Th-series were calculated.

  17. A multistate examination of partnership activity among local public health systems using the National Public Health Performance Standards.

    Science.gov (United States)

    Barnes, Priscilla A; Curtis, Amy B; Hall-Downey, Laura; Moonesinghe, Ramal

    2012-01-01

    This study examines whether partnership-related measures in the second version of the National Public Health Performance Standards (NPHPS) are useful in evaluating level of activity as well as identifying latent constructs that exist among local public health systems (LPHSs). In a sample of 110 LPHSs, descriptive analysis was conducted to determine frequency and percentage of 18 partnership-related NPHPS measures. Principal components factor analysis was conducted to identify unobserved characteristics that promote effective partnerships among LPHSs. Results revealed that 13 of the 18 measures were most frequently reported at the minimal-moderate level (conducted 1%-49% of the time). Coordination of personal health and social services to optimize access (74.6%) was the most frequently reported measure at minimal-moderate levels. Optimal levels (conducted >75% of the time) were reported most frequently in 2 activities: participation in emergency preparedness coalitions and local health departments ensuring service provision by working with state health departments (67% and 61% of respondents, respectively) and the least optimally reported activity was review partnership effectiveness (4% of respondents). Factor analysis revealed categories of partnership-related measures in 4 domains: resources and activities contributing to relationship building, evaluating community leadership activities, research, and state and local linkages to support public health activities. System-oriented public health assessments may have questions that serve as proxy measures to examine levels of interorganizational partnerships. Several measures from the NPHPS were useful in establishing a national baseline of minimal and optimal activity levels as well as identifying factors to enhance the delivery of the 10 essential public health services among organizations and individuals in public health systems.

  18. Calibration of a detector by activation with a continuous neutron source used as a transfer standard for measuring pulsed neutron beams

    International Nuclear Information System (INIS)

    Moreno, Jose; Silva, Patricio; Birstein, Lipo; Soto, Leopoldo

    2002-01-01

    This paper presents a method for calibrating activation detectors. These detectors will be used as transfer standard in measuring neutron fluxes produced by pulsed plasma sources. A standard neutron source is used as a secondary standard. The activation detector is being shielded in order to substantially reduce detection of gamma emission coming from the source. The detector's calibration factor is obtained by considering also the standard neutron source as a free source of gamma radiation so that the measurements can be done without quickly withdrawing the neutron source as it is usually done. This will substantially simplify the traditionally established method (JM)

  19. Evaluation of Antibacterial Activity of Satureja Khuzestanica J. Essential Oil against Standard and Isolated Strains of Listeria monocytogenes

    Directory of Open Access Journals (Sweden)

    Sheida Akbari-Shahabi

    2014-10-01

    Full Text Available Background: The purpose of this study was to determine antibacterial activity of essential oil of Satureja khuzestanica against Listeria monocytogenes (PTCC1295 and strains isolated from breast milk show that. Materials and Methods: In this descriptive-analytic study, Essence of leave’s plant was extracted and identified its compounds and then carvacrol was isolated. Antibacterial activities were examined by agar dilution method against L. monocytogenes. Minimum inhibitory concentration (MIC and minimum bacterial concentration (MBC were carried out by micro dilution method. Then bacterial suspension injected the BALB/c mice. Forty-eight h after seeing the listeriosis disease signs were started the treatment. Ampicillin (10 μg/disc and trimethoprim (5 g were used as controls. Results: The results showed that the inhibitory zone diameter standard and essential oils for strains isolated species were respectively 59 and 50 mm. This amount was determined by carvacrol, respectively, 60 and 48 mm. Inhibition zone diameter measurements for standard strains of ampicillin and trimethoprim tedious strains, respectively, 21, 40, 18 and 33 mm, respectively. The minimum inhibitory concentration of essential oils, carvacrol and ampicillin than standard strains, respectively 1.56, 1.56 and 155×10˗8 μg/mL and MBC 3.125, 3.125 and 125×10-7 μg/mL was determined by the ratio of the strain 3.125, 3.125 and 0.0062 μg/mL and MBC was 6.25, 6.25 and 0.025 μg/mL. Conclusion: This study showed that bacterial cleansing properties of essential oil of this plant have a strong and effective combination that is carvacrol.

  20. Caracterização microestrutural de soldas dissimilares dos aços ASTM A-508 e AISI 316L Characterization of dissimilar metal weld between low alloy steel ASTM A-508 and 316L stainless steel

    Directory of Open Access Journals (Sweden)

    Luciana Iglésias Lourenço Lima

    2010-06-01

    Full Text Available As soldas dissimilares (dissimilar metal welds - DMWs são utilizadas em diversos segmentos da indústria. No caso específico de usinas nucleares, tais soldas são necessárias para conectar tubulações de aço inoxidável com componentes fabricados em aços baixa liga. Os materiais de adição mais utilizados neste tipo de solda são as ligas de níquel 82 e 182. Este trabalho consistiu na soldagem de uma junta dissimilar de aço baixa liga ASTM A-508 G3 e aço inoxidável austenítico AISI 316L utilizando as ligas de níquel 82 e 182 como metais de adição. A soldagem foi realizada manualmente empregando os processos de soldagem ao arco SMAW (Shielded Metal Arc Welding e GTAW (Gas Tungsten Arc Welding. Os corpos de prova foram caracterizados microestruturalmente utilizando-se microscópio óptico e microscópio eletrônico de varredura com microanálise por dispersão de energia de raios X (EDS e ensaios de microdureza Vickers. Observou-se uma microestrutura constituída de dendritas de austenita com a presença de precipitados com formas e dimensões definidas pelo aporte térmico e pela direção de soldagem. Não houve variação significativa da dureza ao longo da junta soldada, demonstrando a adequação dos parâmetros de soldagem utilizados.The dissimilar metal welds (DMWs are used in several areas of the industries. In the nuclear power plant, this weld using nickel alloy welding wires is used to connect stainless steel pipes to low alloy steel components on the reactor pressured vessels. The filler materials commonly used in this type of weld are nickel alloys 82 and 182.. In this study, dissimilar metal welds composed of low alloy steel ASTM A-508 G3, nickel alloys 82 e 182 as weld metals, and austenitic stainless steel AISI 316L were prepared by manual shielded metal arc welding (SMAW and gas tungsten arc welding techniques (GTAW. Samples were microstructural characterized by optical microscopy and scanning electron microscopy

  1. Effect of using the double layer technique on the microstructure, microhardness and residual stress of welded ASTM A516 GR70 structural steel

    International Nuclear Information System (INIS)

    Oliveira, George Luiz Gomes de; Miranda, Helio Cordeiro de

    2010-01-01

    The aim of this work is to evaluate the effect of using the double layer technique on the microstructure, microhardness and residual stresses of welded ASTM A516 Gr70 structural steel. Samples were welded with the same welding parameters and two types of chamfers, while the samples welded using the double layer technique underwent a buttering process on their chamfer face. Residual stress measurement was accomplished through x-ray diffraction, using a mini diffractometer for measurement in field. Metallographic analysis was accomplished in the transverse section of the welded joint, using optic microscopy and scanning electron microscopy. The double layer technique showed that can be used in the welding of ASTM A516 Gr70 steel, because, besides promote a refinement and a drawing back of the CG-HAZ, it increased compressive residual stress in the whole surface of the analyzed samples.(author)

  2. MÉTODOS PARA CARACTERIZAR COMBUSTIBLES LÍQUIDOS Y GASEOSOS OBTENIDOS DE LLANTAS EN DESUSO A TRAVÉS DE LAS NORMAS ASTM.

    Directory of Open Access Journals (Sweden)

    JAIME ALEJANDRO OSPINA

    2011-12-01

    Full Text Available Este artículo muestra la importancia de la caracterización de la energía de combustibles líquidos y gaseosos obtenidos del conocido tratamiento térmico de pirolisis a través de un microondas. La caracterización de estos combustibles tomará en cuenta los estándares técnicos tales como ASTM D3452 – 93 para la cromatografía de gases (GC, ASTM D2549 para cromatografía de gas/ espectrometría de masa (GC/MS y ASTM D6370 -99 para termogravimetría en el análisis de la composición de llantas.También muestra que estos combustibles y gases de pirolisis tiene una alta valor calorífico de 42 MJ / Kg y un contenido de azufre entre 0.8 y 1.65 Wt%, dependiendo en el tipo de llanta y las condiciones del proceso.

  3. Impact of a product-specific reference standard for the measurement of a PEGylated rFVIII activity: the Swiss Multicentre Field Study.

    Science.gov (United States)

    Bulla, O; Poncet, A; Alberio, L; Asmis, L M; Gähler, A; Graf, L; Nagler, M; Studt, J-D; Tsakiris, D A; Fontana, P

    2017-07-01

    Measuring factor VIII (FVIII) activity can be challenging when it has been modified, such as when FVIII is pegylated to increase its circulating half-life. Use of a product-specific reference standard may help avoid this issue. Evaluate the impact of using a product-specific reference standard for measuring the FVIII activity of BAX 855 - a pegylated FVIII - in eight of Switzerland's main laboratories. Factor VIII-deficient plasma, spiked with five different concentrations of BAX 855, plus a control FVIII sample, was sent to the participating laboratories. They measured FVIII activity by using either with a one-stage (OSA) or the chromogenic assay (CA) against their local or a product-specific reference standard. When using a local reference standard, there was an overestimation of BAX 855 activity compared to the target concentrations, both with the OSA and CA. The use of a product-specific reference standard reduced this effect: mean recovery ranged from 127.7% to 213.5% using the OSA with local reference standards, compared to 110% to 183.8% with a product-specific reference standard, and from 146.3% to 182.4% using the CA with local reference standards compared to 72.7% to 103.7% with a product-specific reference standard. In this in vitro study, the type of reference standard had a major impact on the measurement of BAX 855 activity. Evaluation was more accurate and precise when using a product-specific reference standard. © 2017 John Wiley & Sons Ltd.

  4. Problems of drawing up standards for persons simultaneously engaged in more than one activity involving radiation hazards

    International Nuclear Information System (INIS)

    Lucci, F.; Pelliccioni, M.

    1979-01-01

    The authors examine, from the points of view of the ICRP recommendations and of national and international standards, radiation protection problems posed by persons simultaneously engaged in professional activities involving radiation hazards in more than one place. The consequences of this type of situation, for the radiological protection classification of workers and for the evaluation and recording of doses received, are described in detail. In order to ensure proper monitoring of doses, agreements must be reached in advance between those in charge of the different areas of activity. Three cases seem to be of particular relevance: (a) that of workers who, while working for a single employer, perform in more than one place activities in which they are exposed to ionizing radiation (scientists working at different research centres, employees of companies specialized in the nuclear field, including the use of isotopes, accelerators, etc.); (b) that of workers who are engaged by more than one employer and are exposed to ionizing radiations as a result of their activities at different establishments (a special case is that of doctors who are radiologists or specialists in some other branch of nuclear medicine and work both as employees and independently in their own practices); and (c) that of employees of outside organizations not directly concerned with nuclear activities who are only exposed to ionizing radiation when called upon to work in establishments possessing sources of radiation. Finally, the authors suggest some ways of solving these problems - though they are rather difficult to define objectively (for example the case of medical practioners). (author)

  5. Microstructural evolution of ASTM P91 after 100,000 hours exposure at 550 C and 600 C

    Energy Technology Data Exchange (ETDEWEB)

    Cipolla, L.; Venditti, D.; Di Gianfrancesco, A. [Centro Sviluppo Materiali SpA, Rome (Italy); Caminada, S. [TenarisDalmine, Dalmine (Italy); Danielsen, H.K. [Technical Univ. of Denmark, Lyngby (Denmark)

    2010-07-01

    ASTM A335 P91 samples were investigated after creep testing at 550 C and 600 C for over 10{sup 5} h. X-Ray Diffraction, Scanning and Transmission Electron Microscopy were adopted to assess the microstructural evolution of the material in terms of precipitation changes during high temperature exposure. Mean equivalent diameters and average chemical compositions of MX and M{sub 23}C{sub 6} precipitates and Laves phases were assessed through the analysis of a large number of particles. Their growth and coarsening kinetics were determined at 600 C on many samples with increasing exposure times up to 100,000 hours. Also the presence of modified Z-phase, Cr(V, Nb)N, was investigated. The high microstructural stability of Grade 91 is related to the presence of fine and distributed MX carbonitrides, always present even after very long term temperature exposure. The mean size of MX carbonitrides remains almost constant and stays below 45 nm after 10{sup 5} h at 600 C. Although MX particles exhibit a Cr enrichment with increasing ageing times, indicating that they are absorbing Cr atoms from the surrounding matrix, their transformation into Z-phase is still at a very preliminary stage: only a few hybrid MX/Z particles and a few Z-phase precipitates were identified in the most aged sample after 10{sup 5} at 600 C. Coarsening of M{sub 23}C{sub 6} occurs during thermal exposure, but their average equivalent diameter, initially of 140 nm in the as-treated material, remains below 200 nm after 10{sup 5} h at 600 C. Laves particles form at grain boundaries after a relatively short time and soon become the largest precipitates. (orig.)

  6. Anti-allergic activity of standardized extract of Albizia lebbeck with reference to catechin as a phytomarker.

    Science.gov (United States)

    Venkatesh, Pichairajan; Mukherjee, Pulok K; Kumar, Nanjappan Satheesh; Bandyopadhyay, Arun; Fukui, Hiroyuki; Mizuguchi, Hiroyuki; Islam, Nurul

    2010-06-01

    The major groups of phytonutrients found in plants include polyphenols, flavonoids, terpenes, amines, etc., all of which are observed to have potential anti-allergic activity. In this study, we evaluated the anti-allergic activity of the standardized extract of Albizia lebbeck with respect to the catechin, a polyphenolic phytomarker. The percentage of catechin in the ethanolic extract was found to be 14.72 mg/g. We administered Albizia lebbeck (50-300 mg/kg) and 50 mg/kg of catechin to mice to evaluate the mast cell stabilization and estimation of histamine elevation in the plasma. Results support the conclusion that Albizia lebbeck at different concentrations has got potent mast cell stabilizing property and the IC(50) value of Albizia lebbeck was found to be 85 microg/ml. This inhibitory potential of catechin from Albizia lebbeck is perhaps due to modulation of two important effector's functions, histamine release and cytokine expression of antigen -IgE activated mast cells.

  7. Prediction of landslide activation at locations in Beskidy Mountains using standard and real-time monitoring methods

    Science.gov (United States)

    Bednarczyk, Z.

    2012-04-01

    The paper presents landslide monitoring methods used for prediction of landslide activity at locations in the Carpathian Mountains (SE Poland). Different types of monitoring methods included standard and real-time early warning measurement with use of hourly data transfer to the Internet were used. Project financed from the EU funds was carried out for the purpose of public road reconstruction. Landslides with low displacement rates (varying from few mm to over 5cm/year) had size of 0.4-2.2mln m3. Flysch layers involved in mass movements represented mixture of clayey soils and sandstones of high moisture content and plasticity. Core sampling and GPR scanning were used for recognition of landslide size and depths. Laboratory research included index, IL oedometer, triaxial and direct shear laboratory tests. GPS-RTK mapping was employed for actualization of landslide morphology. Instrumentation consisted of standard inclinometers, piezometers and pore pressure transducers. Measurements were carried 2006-2011, every month. In May 2010 the first in Poland real-time monitoring system was installed at landslide complex over the Szymark-Bystra public road. It included in-place uniaxial sensors and 3D continuous inclinometers installed to the depths of 12-16m with tilt sensors every 0.5m. Vibrating wire pore pressure and groundwater level transducers together with automatic meteorological station analyzed groundwater and weather conditions. Obtained monitoring and field investigations data provided parameters for LEM and FEM slope stability analysis. They enabled prediction and control of landslide behaviour before, during and after stabilization or partly stabilization works. In May 2010 after the maximum precipitation (100mm/3hours) the rates of observed displacements accelerated to over 11cm in a few days and damaged few standard inclinometer installations. However permanent control of the road area was possible by continuous inclinometer installations. Comprehensive

  8. A multicenter study to standardize reporting and analyses of fluorescence-activated cell-sorted murine intestinal epithelial cells

    Science.gov (United States)

    Magness, Scott T.; Puthoff, Brent J.; Crissey, Mary Ann; Dunn, James; Henning, Susan J.; Houchen, Courtney; Kaddis, John S.; Kuo, Calvin J.; Li, Linheng; Lynch, John; Martin, Martin G.; May, Randal; Niland, Joyce C.; Olack, Barbara; Qian, Dajun; Stelzner, Matthias; Swain, John R.; Wang, Fengchao; Wang, Jiafang; Wang, Xinwei; Yan, Kelley; Yu, Jian

    2013-01-01

    Fluorescence-activated cell sorting (FACS) is an essential tool for studies requiring isolation of distinct intestinal epithelial cell populations. Inconsistent or lack of reporting of the critical parameters associated with FACS methodologies has complicated interpretation, comparison, and reproduction of important findings. To address this problem a comprehensive multicenter study was designed to develop guidelines that limit experimental and data reporting variability and provide a foundation for accurate comparison of data between studies. Common methodologies and data reporting protocols for tissue dissociation, cell yield, cell viability, FACS, and postsort purity were established. Seven centers tested the standardized methods by FACS-isolating a specific crypt-based epithelial population (EpCAM+/CD44+) from murine small intestine. Genetic biomarkers for stem/progenitor (Lgr5 and Atoh 1) and differentiated cell lineages (lysozyme, mucin2, chromogranin A, and sucrase isomaltase) were interrogated in target and control populations to assess intra- and intercenter variability. Wilcoxon's rank sum test on gene expression levels showed limited intracenter variability between biological replicates. Principal component analysis demonstrated significant intercenter reproducibility among four centers. Analysis of data collected by standardized cell isolation methods and data reporting requirements readily identified methodological problems, indicating that standard reporting parameters facilitate post hoc error identification. These results indicate that the complexity of FACS isolation of target intestinal epithelial populations can be highly reproducible between biological replicates and different institutions by adherence to common cell isolation methods and FACS gating strategies. This study can be considered a foundation for continued method development and a starting point for investigators that are developing cell isolation expertise to study physiology and

  9. Standardization of metachromatic staining method of myofibrillar ATPase activity of myosin to skeletal striated muscle of mules and donkeys

    Directory of Open Access Journals (Sweden)

    Flora H.F. D'Angelis

    2014-09-01

    Full Text Available This study aims at standardizing the pre-incubation and incubation pH and temperature used in the metachromatic staining method of myofibrillar ATPase activity of myosin (mATPase used for asses and mules. Twenty four donkeys and 10 mules, seven females and three males, were used in the study. From each animal, fragments from the Gluteus medius muscle were collected and percutaneous muscle biopsy was performed using a 6.0-mm Bergström-type needle. In addition to the metachromatic staining method of mATPase, the technique of nicotinamide adenine dinucleotide tetrazolium reductase (NADH-TR was also performed to confirm the histochemical data. The histochemical result of mATPase for acidic pre-incubation (pH=4.50 and alkaline incubation (pH=10.50, at a temperature of 37ºC, yielded the best differentiation of fibers stained with toluidine blue. Muscle fibers were identified according to the following colors: type I (oxidative, light blue, type IIA (oxidative-glycolytic, intermediate blue and type IIX (glycolytic, dark blue. There are no reports in the literature regarding the characterization and distribution of different types of muscle fibers used by donkeys and mules when performing traction work, cargo transportation, endurance sports (horseback riding and marching competitions. Therefore, this study is the first report on the standardization of the mATPase technique for donkeys and mules.

  10. Hepatoprotective Activity of Herbal Composition SAL, a Standardize Blend Comprised of Schisandra chinensis, Artemisia capillaris, and Aloe barbadensis

    Directory of Open Access Journals (Sweden)

    Mesfin Yimam

    2016-01-01

    Full Text Available Some botanicals have been reported to possess antioxidative activities acting as scavengers of free radicals rendering their usage in herbal medicine. Here we describe the potential use of “SAL,” a standardized blend comprised of three extracts from Schisandra chinensis, Artemisia capillaris, and Aloe barbadensis, in mitigating chemically induced acute liver toxicities. Acetaminophen and carbon tetrachloride induced acute liver toxicity models in mice were utilized. Hepatic functional tests from serum collected at T24 and hepatic glutathione and superoxide dismutases from liver homogenates were evaluated. Histopathology analysis and merit of blending 3 standardized extracts were also confirmed. Statistically significant and dose-correlated inhibitions in serum ALT ranging from 52.5% (p=0.004 to 34.6% (p=0.05 in the APAP and 46.3% (p<0.001 to 29.9% (p=0.02 in the CCl4 models were observed for SAL administered at doses of 400–250 mg/kg. Moreover, SAL resulted in up to 60.6% and 80.2% reductions in serums AST and bile acid, respectively. The composition replenished depleted hepatic glutathione in association with an increase of hepatic superoxide dismutase. Unexpected synergistic protection from liver damage was also observed. Therefore, the composition SAL could be potentially utilized as an effective hepatic-detoxification agent for the protection from liver damage.

  11. Development and testing of standardized procedures and reference data for LWR surveillance

    International Nuclear Information System (INIS)

    McElroy, W.N.

    1979-02-01

    The resources and talents of many national and international organizations and laboratories, both governmental and industrial, are being used to establish analysis methods for predicting the embrittlement condition of light water reactor (LWR) primary systems. The exact interrelationships and responsibilities between those developing, understanding, combining, and applying state-of-the-art technology in dosimetry, metallurgy, and fracture mechanics for reactor systems analysis are being carefully reviewed and studied. This has resulted in a more comprehensive definition of the scope of new and updated ASTM standards required for the analysis and interpretation of LWR pressure vessel surveillance results. Fifteen new and updated ASTM standards have now been identified, together with a restructuring of the main interfaces between the individual standard practices, guides, and methods. The paper briefly discusses these standards and the initial results of multi-laboratory research work involved in their validation and calibration

  12. Standards for gene therapy clinical trials based on pro-active risk assessment in a London NHS Teaching Hospital Trust.

    Science.gov (United States)

    Bamford, K B; Wood, S; Shaw, R J

    2005-02-01

    Conducting gene therapy clinical trials with genetically modified organisms as the vectors presents unique safety and infection control issues. The area is governed by a range of legislation and guidelines, some unique to this field, as well as those pertinent to any area of clinical work. The relevant regulations covering gene therapy using genetically modified vectors are reviewed and illustrated with the approach taken by a large teaching hospital NHS Trust. Key elements were Trust-wide communication and involvement of staff in a pro-active approach to risk management, with specific emphasis on staff training and engagement, waste management, audit and record keeping. This process has led to the development of proposed standards for clinical trials involving genetically modified micro-organisms.

  13. 78 FR 64475 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe (Over 41/2

    Science.gov (United States)

    2013-10-29

    ... stress levels. Alloy pipes made to ASTM A-335 standard must be used if temperatures and stress levels..., or pressure pipe applications. B. Finished and unfinished oil country tubular goods (OCTG), if covered by the scope of another antidumping duty order from the same country. If not covered by such an...

  14. 76 FR 62762 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line and Pressure Pipe From Japan...

    Science.gov (United States)

    2011-10-11

    ... Fahrenheit, at various American Society of Mechanical Engineers (``ASME'') code stress levels. Alloy pipes made to ASTM A-335 standard must be used if temperatures and stress levels exceed those allowed for..., or pressure pipe applications. B. Finished and unfinished oil country tubular goods (``OCTG''), if...

  15. 75 FR 38781 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe From Japan...

    Science.gov (United States)

    2010-07-06

    ... Fahrenheit, at various American Society of Mechanical Engineers (``ASME'') code stress levels. Alloy pipes made to ASTM A-335 standard must be used if temperatures and stress levels exceed those allowed for.... B. Finished and unfinished oil country tubular goods (``OCTG''), if covered by the scope of another...

  16. Combined antibacterial activity of stingless bee (Apis mellipodae) honey and garlic (Allium sativum) extracts against standard and clinical pathogenic bacteria

    Science.gov (United States)

    Andualem, Berhanu

    2013-01-01

    Objective To investigate the synergic antibacterial activity of garlic and tazma honey against standard and clinical pathogenic bacteria. Methods Antimicrobial activity of tazma honey, garlic and mixture of them against pathogenic bacteria were determined. Chloramphenicol and water were used as positive and negative controls, respectively. Minimum inhibitory concentration (MIC) and minimum bactericidal concentration of antimicrobial samples were determined using standard methods. Results Inhibition zone of mixture of garlic and tazma honey against all tested pathogens was significantly (P≤0.05) greater than garlic and tazma honey alone. The diameter zone of inhibition ranged from (18±1) to (35±1) mm for mixture of garlic and tazma honey, (12±1) to (20±1) mm for tazma honey and (14±1) to (22±1) mm for garlic as compared with (10±1) to (30±1) mm for chloramphenicol. The combination of garlic and tazma honey (30-35 mm) was more significantly (P≤0.05) effective against Salmonella (NCTC 8385), Staphylococcus aureus (ATCC 25923), Lyesria moncytogenes (ATCC 19116) and Streptococcus pneumonia (ATCC 63). Results also showed considerable antimicrobial activity of garlic and tazma honey. MIC of mixture of garlic and tazma honey at 6.25% against total test bacteria was 88.9%. MIC of mixture of garlic and tazma honey at 6.25% against Gram positive and negative were 100% and 83.33%, respectively. The bactericidal activities of garlic, tazma honey, and mixture of garlic and tazma honey against all pathogenic bacteria at 6.25% concentration were 66.6%, 55.6% and 55.6%, respectively. Conclusions This finding strongly supports the claim of the local community to use the combination of tazma honey and garlic for the treatment of different pathogenic bacterial infections. Therefore, garlic in combination with tazma honey can serve as an alternative natural antimicrobial drug for the treatment of pathogenic bacterial infections. Further in vivo study is recommended to come

  17. Effluent standards

    Energy Technology Data Exchange (ETDEWEB)

    Geisler, G C [Pennsylvania State University (United States)

    1974-07-01

    At the conference there was a considerable interest in research reactor standards and effluent standards in particular. On the program, this is demonstrated by the panel discussion on effluents, the paper on argon 41 measured by Sims, and the summary paper by Ringle, et al. on the activities of ANS research reactor standards committee (ANS-15). As a result, a meeting was organized to discuss the proposed ANS standard on research reactor effluents (15.9). This was held on Tuesday evening, was attended by members of the ANS-15 committee who were present at the conference, participants in the panel discussion on the subject, and others interested. Out of this meeting came a number of excellent suggestions for changes which will increase the utility of the standard, and a strong recommendation that the effluent standard (15.9) be combined with the effluent monitoring standard. It is expected that these suggestions and recommendations will be incorporated and a revised draft issued for comment early this summer. (author)

  18. Standard Test Method for Oxygen Content Using a 14-MeV Neutron Activation and Direct-Counting Technique

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method covers the measurement of oxygen concentration in almost any matrix by using a 14-MeV neutron activation and direct-counting technique. Essentially, the same system may be used to determine oxygen concentrations ranging from over 50 % to about 10 g/g, or less, depending on the sample size and available 14-MeV neutron fluence rates. Note 1 - The range of analysis may be extended by using higher neutron fluence rates, larger samples, and higher counting efficiency detectors. 1.2 This test method may be used on either solid or liquid samples, provided that they can be made to conform in size, shape, and macroscopic density during irradiation and counting to a standard sample of known oxygen content. Several variants of this method have been described in the technical literature. A monograph is available which provides a comprehensive description of the principles of activation analysis using a neutron generator (1). 1.3 The values stated in either SI or inch-pound units are to be regarded...

  19. Standardized Cost Structure for the Environmental Industry

    International Nuclear Information System (INIS)

    Skokan, B.; Melamed, D.; Guevara, K.; Mallick, P.; Bierman, G.; Marshall, H.E.

    2006-01-01

    The underlying key to developing successful estimates, tracking project costs, and utilizing historical project cost information is the development of standardized and well-defined hierarchical listing of cost categories. Committees within the U.S. Federal agencies have pioneered efforts toward developing the Environmental Cost Element Structure (ECES), which is key in achieving these goals. The ECES was developed using an iterative process with input from federal agencies and industry. Experts from several disciplines participated including engineers, cost estimators, project/program managers, and contract personnel. The ECES benefits from an intense analytical effort, the knowledge gained from the maturation of the environmental industry, and incorporation of past user's experiences. Building upon this foundation, the E06 committee of the ASTM International has now fully developed and published a standard (ASTM 2150-04) that provides standardized cost categories with complete cost category definitions. This standard affords environmental and nuclear D and D project managers the opportunity to have a well defined hierarchical listing of their estimates and actual costs, readily adapted to performing summations and roll-ups, supported by a multi-level dictionary specifically defining the content of the cost elements as well as the summations. Owing to the dynamic nature of the environmental technologies, efforts need to be made to continue to update this standard by adding new technologies and methods as they are developed and employed in the field. Lastly, the Environmental Cost Element Structure that is embodied in this standard also presents opportunities to develop historical cost databases and comprehensive life cycle cost estimates and standardized cost estimating tools. (authors)

  20. Standardization process for pipeline right-of-way activities: the case of TRANSPETRO's Oil Pipeline and Terminals Business Unit

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Kassandra Senra de Morais M.; Goncalves, Bruno Martins [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil). Diretoria de Terminais e Oleodutos; Almeida, Maria Fatima Ludovico de [Pontificia Universidade Catolica do Rio de Janeiro (PUC-Rio/ITUC), Rio de Janeiro, RJ (Brazil). Instituto Tecnologico

    2009-07-01

    This paper describes the experience of PETROBRAS Transporte S.A. concerning the standardization process for its pipeline right-of-way (ROW) activities. This standardization initiative has been carried out within the Oil Pipelines and Terminals Standardization Program (PRONOT), focusing on planning, standardization and implementation of all norms and corporate procedures referring to TRANSPETRO's right-of-way activities. The process promoted the integration of isolated regional initiatives, a sense of unity and the creation of a learning network consisting of 60 employees. This paper presents the last phase's results concerning implementation of corporate standards, based upon achievements of previous phases. It covers the following topics: a general view of the whole process by way of introduction; the potential of integration of recent standardization results with TRANSPETRO's corporate management tools and information systems; definition of four performance indicators and their metrics related to pipeline right-of-way management, as well as a corporate standard for the requirements for contracting services related to rights-of-way inspection, maintenance and communication; challenges, barriers and benefits perceived by the team responsible for formulating and implementing standards and procedures in TRANSPETRO's Oil Pipelines and Terminals Unit. (author)

  1. Hypoglycemic and Hypotensive Activity of a Root Extract of Smilax aristolochiifolia, Standardized on N-trans-Feruloyl-Tyramine

    Directory of Open Access Journals (Sweden)

    Carol Arely Botello Amaro

    2014-07-01

    Full Text Available The metabolic syndrome (MS is a condition consisting of various metabolic abnormalities that are risk factors for developing kidney failure, cardiovascular, vascular and cerebrovascular diseases, among others. The prevalence of this syndrome shows a marked increase. The aim of this study was to investigate the pharmacological effect of Smilax aristolochiifolia root on some components of MS and obtain some of the active principle using chromatographic techniques. The compound isolated was N-trans-feruloyl tyramine NTF (1, and its structure was determined by spectroscopic and spectrometric analyses. The whole extract and the standardized fractions were able to control the weight gain around 30%; the fraction rich in NTF was able to decrease the hypertriglyceridemia by 60%. The insulin resistance decreased by approximately 40%; the same happened with blood pressure, since the values of systolic and diastolic pressure fell on average 31% and 37% respectively, to levels comparable to normal value. The treatment also had an immunomodulatory effect on the low-grade inflammation associated with obesity, since it significantly decreased the relative production of pro-inflammatory cytokines regarding anti-inflammatory cytokines, both kidney and adipose tissue. Therefore it can be concluded that the extract and fractions of Smilax aristolochiifolia root with NTF are useful to counteract some symptoms of MS in animal models.

  2. Multielement analysis of human hair and kidney stones by instrumental neutron activation analysis with the k0-standardization method

    International Nuclear Information System (INIS)

    Abugassa, I.; Sarmani, S.B.; Samat, S.B.

    1999-01-01

    This paper focuses on the evaluation of the k 0 method of instrumental neutron activation analysis in biological materials. The method has been applied in multielement analysis of human hair standard reference materials from IAEA, No. 085, No. 086 and from NIES (National Institute for Environmental Sciences) No. 5. Hair samples from people resident in different parts of Malaysia, in addition to a sample from Japan, were analyzed. In addition, human kidney stones from members of the Malaysian population have been analyzed for minor and trace elements. More than 25 elements have been determined. The samples were irradiated in the rotary rack (Lazy Susan) at the TRIGA Mark II reactor of the Malaysian Institute for Nuclear Technology and Research (MINT). The accuracy of the method was ascertained by analysis of other reference materials, including 1573 tomato leaves and 1572 citrus leaves. In this method the deviation of the 1/E 1+α epithermal neutron flux distribution from the 1/E law (P/T ratio) for true coincidence effects of the γ-ray cascade and the HPGe detector efficiency were determined and corrected for

  3. Determination of multi-element composition of Vietnamese marine sediment and tuna fish by k0-standardized neutron activation analysis

    International Nuclear Information System (INIS)

    Manh-Dung Ho; Quang-Thien Tran; Van-Doanh Ho; Thi-Sy Nguyen

    2016-01-01

    The k 0 -standardized neutron activation analysis (k 0 -NAA) has been applied for determination of multiple elements (25 elements: Al, As, Ba, Br, Ca, Cl, Co, Cr, Cs, Cu, Eu, Fe, Hg, K, La, Mg, Na, Rb, Sc, Se, Sm, Th, Ti, V and Zn) in marine sediment and tuna fish. About 50 marine sediment and 9 tuna fish samples were collected in two coastal areas of Vietnam. The health risk index (HRI) values of As and Br were higher than 1.0 for the tuna fish. Also, HRI value of Hg was 8.92 × 10 -1 indicating a relatively high potential health risk, whiles Co and Mn with HRIs = 1.56 × 10 -4 and 8.56 × 10 -4 , respectively, have the lowest potential health risks. Average enrichment factors using Al as a reference element (EF Al ) were higher than 1.5 for Eu, La, Zn, Th, Cs and As in which the highest EF Al value for As was higher than 10. This study showed that the HRI value of As in the tuna fish correlated positively with the EF Al value for the element in the marine sediment. (author)

  4. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  5. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  6. Computer program for obtaining thermodynamic and transport properties of air and products of combustion of ASTM-A-1 fuel and air

    Science.gov (United States)

    Hippensteele, S. A.; Colladay, R. S.

    1978-01-01

    A computer program for determining desired thermodynamic and transport property values by means of a three-dimensional (pressure, fuel-air ratio, and either enthalpy or temperature) interpolation routine was developed. The program calculates temperature (or enthalpy), molecular weight, viscosity, specific heat at constant pressure, thermal conductivity, isentropic exponent (equal to the specific heat ratio at conditions where gases do not react), Prandtl number, and entropy for air and a combustion gas mixture of ASTM-A-1 fuel and air over fuel-air ratios from zero to stoichiometric, pressures from 1 to 40 atm, and temperatures from 250 to 2800 K.

  7. Dosimetry standards for radiation processing

    International Nuclear Information System (INIS)

    Farrar, H. IV

    1999-01-01

    For irradiation treatments to be reproducible in the laboratory and then in the commercial environment, and for products to have certified absorbed doses, standardized dosimetry techniques are needed. This need is being satisfied by standards being developed by experts from around the world under the auspices of Subcommittee E10.01 of the American Society for Testing and Materials (ASTM). In the time period since it was formed in 1984, the subcommittee has grown to 150 members from 43 countries, representing a broad cross-section of industry, government and university interests. With cooperation from other international organizations, it has taken the combined part-time effort of all these people more than 13 years to complete 24 dosimetry standards. Four are specifically for food irradiation or agricultural applications, but the majority apply to all forms of gamma, x-ray, Bremsstrahlung and electron beam radiation processing, including dosimetry for sterilization of health care products and the radiation processing of fruits, vegetables, meats, spices, processed foods, plastics, inks, medical wastes and paper. An additional 6 standards are under development. Most of the standards provide exact procedures for using individual dosimetry systems or for characterizing various types of irradiation facilities, but one covers the selection and calibration of dosimetry systems, and another covers the treatment of uncertainties. Together, this set of standards covers essentially all aspects of dosimetry for radiation processing. The first 20 of these standards have been adopted in their present form by the International Organization of Standardization (ISO), and will be published by ISO in 1999. (author)

  8. Involvement of monoaminergic systems in anxiolytic and antidepressive activities of the standardized extract of Cocos nucifera L.

    Science.gov (United States)

    Lima, Eliane Brito Cortez; de Sousa, Caren Nádia Soares; Meneses, Lucas Nascimento; E Silva Pereira, Yuri Freitas; Matos, Natália Castelo Branco; de Freitas, Rayanne Brito; Lima, Nycole Brito Cortez; Patrocínio, Manoel Cláudio Azevedo; Leal, Luzia Kalyne Almeida Moreira; Viana, Glauce Socorro Barros; Vasconcelos, Silvânia Maria Mendes

    2017-01-01

    Extracts from the husk fiber of Cocos nucifera are used in folk medicine, but their actions on the central nervous system have not been studied. Here, the anxiolytic and antidepressant effects of the standardized hydroalcoholic extract of C. nucifera husk fiber (HECN) were evaluated. Male Swiss mice were treated with HECN (50, 100, or 200 mg/kg) 60 min before experiments involving the plus maze test, hole-board test, tail suspension test, and forced swimming test (FST). HECN was administered orally (p.o.) in acute and repeated-dose treatments. The forced swimming test was performed with dopaminergic and noradrenergic antagonists, as well as a serotonin release inhibitor. Administration of HECN in the FST after intraperitoneal (i.p.) pretreatment of mice with sulpiride (50 mg/kg), prazosin (1 mg/kg), or p-chlorophenylalanine (PCPA, 100 mg/kg) caused the actions of these three agents to be reversed. However, this effect was not observed after pretreating the animals with SCH23390 (15 µg/kg, i.p.) or yohimbine (1 mg/kg, i.p.) The dose chosen for HECN was 100 mg/kg, p.o., which increased the number of entries as well as the permanence in the open arms of the maze after acute and repeated doses. In both the forced swimming and the tail suspension tests, the same dose decreased the time spent immobile but did not disturb locomotor activity in an open-field test. The anxiolytic effect of HECN appears to be related to the GABAergic system, while its antidepressant effect depends upon its interaction with the serotoninergic, noradrenergic (α1 receptors), and dopaminergic (D2 dopamine receptors) systems.

  9. The Trends and Prospects of Health Information Standards : Standardization Analysis and Suggestions

    International Nuclear Information System (INIS)

    Kim, Chang Soo

    2008-01-01

    Ubiquitous health care system, which is one of the developing solution technologies of IT, BT and NT, could give us new medical environments in future. Implementing health information systems can be complex, expensive and frustrating. Healthcare professionals seeking to acquire or upgrade systems do not have a convenient, reliable way of specifying a level of adherence to communication standards sufficient to achieve truly efficient interoperability. Great progress has been made in establishing such standards-DICOM, IHE and HL7, notably, are now highly advanced. IHE has defined a common framework to deliver the basic interoperability needed for local and regional health information networks. It has developed a foundational set of standards-based integration profiles for information exchange with three interrelated efforts. HL7 is one of several ANSI-accredited Standards Developing Organizations operating in the healthcare arena. Most SDOs produce standards (protocols) for a particular healthcare domain such as pharmacy, medical devices, imaging or insurance transactions. HL7's domain is clinical and administrative data. HL7 is an international community of healthcare subject matter experts and information scientists collaborating to create standards for the exchange, management and integration of electronic healthcare information. The ASTM specification for Continuity of Care Record was developed by subcommittee E31.28 on electronic health records, which includes clinicians, provider institutions, administrators, patient advocates, vendors, and health industry. In this paper, there are suggestions that provide a test bed, demonstration and specification of how standards such a IHE, HL7, ASTM can be used to provide an integrated environment.

  10. The Trends and Prospects of Health Information Standards : Standardization Analysis and Suggestions

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Soo [Dept. of Radiological Science, College of Health Science, Catholic University of Pusan, Pusan (Korea, Republic of)

    2008-03-15

    Ubiquitous health care system, which is one of the developing solution technologies of IT, BT and NT, could give us new medical environments in future. Implementing health information systems can be complex, expensive and frustrating. Healthcare professionals seeking to acquire or upgrade systems do not have a convenient, reliable way of specifying a level of adherence to communication standards sufficient to achieve truly efficient interoperability. Great progress has been made in establishing such standards-DICOM, IHE and HL7, notably, are now highly advanced. IHE has defined a common framework to deliver the basic interoperability needed for local and regional health information networks. It has developed a foundational set of standards-based integration profiles for information exchange with three interrelated efforts. HL7 is one of several ANSI-accredited Standards Developing Organizations operating in the healthcare arena. Most SDOs produce standards (protocols) for a particular healthcare domain such as pharmacy, medical devices, imaging or insurance transactions. HL7's domain is clinical and administrative data. HL7 is an international community of healthcare subject matter experts and information scientists collaborating to create standards for the exchange, management and integration of electronic healthcare information. The ASTM specification for Continuity of Care Record was developed by subcommittee E31.28 on electronic health records, which includes clinicians, provider institutions, administrators, patient advocates, vendors, and health industry. In this paper, there are suggestions that provide a test bed, demonstration and specification of how standards such a IHE, HL7, ASTM can be used to provide an integrated environment.

  11. Fitting psychometric functions using a fixed-slope parameter: an advanced alternative for estimating odor thresholds with data generated by ASTM E679.

    Science.gov (United States)

    Peng, Mei; Jaeger, Sara R; Hautus, Michael J

    2014-03-01

    Psychometric functions are predominately used for estimating detection thresholds in vision and audition. However, the requirement of large data quantities for fitting psychometric functions (>30 replications) reduces their suitability in olfactory studies because olfactory response data are often limited (ASTM) E679. The slope parameter of the individual-judge psychometric function is fixed to be the same as that of the group function; the same-shaped symmetrical sigmoid function is fitted only using the intercept. This study evaluated the proposed method by comparing it with 2 available methods. Comparison to conventional psychometric functions (fitted slope and intercept) indicated that the assumption of a fixed slope did not compromise precision of the threshold estimates. No systematic difference was obtained between the proposed method and the ASTM method in terms of group threshold estimates or threshold distributions, but there were changes in the rank, by threshold, of judges in the group. Overall, the fixed-slope psychometric function is recommended for obtaining relatively reliable individual threshold estimates when the quantity of data is limited.

  12. Application of Response Surface Methodology for Modeling of Postweld Heat Treatment Process in a Pressure Vessel Steel ASTM A516 Grade 70.

    Science.gov (United States)

    Peasura, Prachya

    2015-01-01

    This research studied the application of the response surface methodology (RSM) and central composite design (CCD) experiment in mathematical model and optimizes postweld heat treatment (PWHT). The material of study is a pressure vessel steel ASTM A516 grade 70 that is used for gas metal arc welding. PWHT parameters examined in this study included PWHT temperatures and time. The resulting materials were examined using CCD experiment and the RSM to determine the resulting material tensile strength test, observed with optical microscopy and scanning electron microscopy. The experimental results show that using a full quadratic model with the proposed mathematical model is YTS = -285.521 + 15.706X1 + 2.514X2 - 0.004X1(2) - 0.001X2(2) - 0.029X1X2. Tensile strength parameters of PWHT were optimized PWHT time of 5.00 hr and PWHT temperature of 645.75°C. The results show that the PWHT time is the dominant mechanism used to modify the tensile strength compared to the PWHT temperatures. This phenomenon could be explained by the fact that pearlite can contribute to higher tensile strength. Pearlite has an intensity, which results in increased material tensile strength. The research described here can be used as material data on PWHT parameters for an ASTM A516 grade 70 weld.

  13. Standard practice for preparation and use of direct tension stress-corrosion test specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This practice covers procedures for designing, preparing, and using ASTM standard tension test specimens for investigating susceptibility to stress-corrosion cracking. Axially loaded specimens may be stressed quantitatively with equipment for application of either a constant load, constant strain, or with a continuously increasing strain. 1.2 Tension test specimens are adaptable for testing a wide variety of product forms as well as parts joined by welding, riveting, or various other methods. 1.3 The exposure of specimens in a corrosive environment is treated only briefly because other standards are being prepared to deal with this aspect. Meanwhile, the investigator is referred to Practices G35, G36, G37, and G44, and to ASTM Special Technical Publication 425 (1).

  14. Development and evaluation of Standard Operating Procedures (SOPs) for quality control tests and radiological protection activities in a Nuclear Medicine Service

    Energy Technology Data Exchange (ETDEWEB)

    Krempser, Alexandre R., E-mail: krempser@peb.ufrj.br [Universidade Federal do Rio de Janeiro (PEB/COPPE/UFRJ), RJ (Brazil). Programa de Engenharia Biomedica; Soares, Alexandre B. [Universidade Federal do Rio de Janeiro (IF/UFRJ), Rio de Janeiro, RJ (Brazil). Inst. de Fisica; Corbo, Rossana [Universidade Federal do Rio de Janeiro (FM/UFRJ), Rio de Janeiro, RJ (Brazil). Dept. de Radiologia

    2011-07-01

    The quality management in Nuclear Medicine Services is a requirement of national and international standards. The Brazilian regulatory agency in health surveillance, the Agencia Nacional de Vigilancia Sanitaria (ANVISA), in its Resolucao de Diretoria Colegiada (Collegiate Directory Resolution) no. 38, requires the elaboration of documents describing the technical and clinical routine activities. This study aimed to elaborate, implement and evaluate Standard Operating Procedures (SOPs) for quality control tests and radiological protection activities in the Nuclear Medicine Service of a university hospital. Eighteen SOPs were developed, involving tasks related to dose calibrator, gamma camera, Geiger-Muller detectors and radiological protection activities. The performance of its application was evaluated for a period of six months. It was observed a reduction in 75% of reported operational errors and 42% of the number of reported incidents with contamination by radioactive material. The SOPs were adequate and successful in its application. New procedures involving clinical activities will also be developed and evaluated. (author)

  15. Technology transfer through a network of standard methods and recommended practices - The case of petrochemicals

    Science.gov (United States)

    Batzias, Dimitris F.; Karvounis, Sotirios

    2012-12-01

    Technology transfer may take place in parallel with cooperative action between companies participating in the same organizational scheme or using one another as subcontractor (outsourcing). In this case, cooperation should be realized by means of Standard Methods and Recommended Practices (SRPs) to achieve (i) quality of intermediate/final products according to specifications and (ii) industrial process control as required to guarantee such quality with minimum deviation (corresponding to maximum reliability) from preset mean values of representative quality parameters. This work deals with the design of the network of SRPs needed in each case for successful cooperation, implying also the corresponding technology transfer, effectuated through a methodological framework developed in the form of an algorithmic procedure with 20 activity stages and 8 decision nodes. The functionality of this methodology is proved by presenting the path leading from (and relating) a standard test method for toluene, as petrochemical feedstock in the toluene diisocyanate production, to the (6 generations distance upstream) performance evaluation of industrial process control systems (ie., from ASTM D5606 to BS EN 61003-1:2004 in the SRPs network).

  16. (60)Co in cast steel matrix: A European interlaboratory comparison for the characterisation of new activity standards for calibration of gamma-ray spectrometers in metallurgy.

    Science.gov (United States)

    Tzika, Faidra; Burda, Oleksiy; Hult, Mikael; Arnold, Dirk; Marroyo, Belén Caro; Dryák, Pavel; Fazio, Aldo; Ferreux, Laurent; García-Toraño, Eduardo; Javornik, Andrej; Klemola, Seppo; Luca, Aurelian; Moser, Hannah; Nečemer, Marijan; Peyrés, Virginia; Reis, Mario; Silva, Lidia; Šolc, Jaroslav; Svec, Anton; Tyminski, Zbigniew; Vodenik, Branko; Wätjen, Uwe

    2016-08-01

    Two series of activity standards of (60)Co in cast steel matrix, developed for the calibration of gamma-ray spectrometry systems in the metallurgical sector, were characterised using a European interlaboratory comparison among twelve National Metrology Institutes and one international organisation. The first standard, consisting of 14 disc shaped samples, was cast from steel contaminated during production ("originally"), and the second, consisting of 15 similar discs, from artificially-contaminated ("spiked") steel. The reference activity concentrations of (60)Co in the cast steel standards were (1.077±0.019) Bqg(-1) on 1 January 2013 12h00 UT and (1.483±0.022) Bqg(-1) on 1 June 2013 12h00 UT, respectively. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Validation of ammonia diffusive and active samplers in a controlled atmosphere test facility using traceable Primary Standard Gas Mixtures

    Science.gov (United States)

    Martin, Nicholas A.; Ferracci, Valerio; Cassidy, Nathan; Hook, Josh; Battersby, Ross M.; Tang, Yuk S.; Stevens, Amy C. M.; Jones, Matthew R.; Braban, Christine F.; Gates, Linda; Hangartner, Markus; Stoll, Jean-Marc; Sacco, Paolo; Pagani, Diego; Hoffnagle, John A.

    2017-04-01

    Intensive animal farming, the increased use of fertilizers, and certain industrial processes are believed to be responsible for the observed increases in the amount fraction of ammonia (NH3) found in Europe. NH3 contributes to eutrophication and acidification of land and freshwater, potentially leading to a loss of biodiversity and undesirable changes to the ecosystem. It also contributes to the formation of secondary particulate matter (PM) formation, which is associated with poor air quality and adverse health outcomes. Measurements of ambient ammonia are principally carried out with low-cost diffusive samplers or by active sampling with denuders, with each method delivering time-integrated values over the monitoring period. However, such techniques have not yet been extensively validated. The goal of this work was to provide improvements in the metrological traceability through the determination of NH3 diffusive sampling rates. Five different designs of commercial diffusive samplers (FSM Radiello radial sampler, Gradko diffusion tube, Gradko DIFRAM-400, Passam ammonia sampler, and CEH ALPHA sampler) were employed, together with a pumped denuder sampler (CEH DELTA denuder) for comparison. All devices were simultaneously exposed for either 28 days or 14 days (dependent on sampler type) in a controlled atmosphere test facility (CATFAC) containing traceable amount fractions of humidified ammonia using new stable ammonia Primary Standard Gas Mixtures developed by gravimetry at NPL, under a wide range of conditions that are relevant to ambient monitoring. Online continuous monitoring of the ammonia test atmospheres was carried out by extractive sampling, employing a calibrated cavity ring-down spectrometer, which had been modified to account for cross interference by water vapour. Each manufacturer extracted the captured ammonia on the exposed samplers in the form of ammonium (NH4+) using their own accredited traceable wet chemical techniques, and then reported data

  18. Analysis of standard fracture toughness test based on digital image correlation data

    Czech Academy of Sciences Publication Activity Database

    Jandejsek, Ivan; Gajdoš, Lubomír; Šperl, Martin; Vavřík, Daniel

    2017-01-01

    Roč. 182, September (2017), s. 607-620 ISSN 0013-7944 R&D Projects: GA ČR(CZ) GA15-07210S; GA TA ČR(CZ) TE02000162 Keywords : DIC * full-field measurement * J-integral * CTOD * ASTM standard Subject RIV: JL - Materials Fatigue, Friction Mechanics OBOR OECD: Audio engineering, reliability analysis Impact factor: 2.151, year: 2016 http://www.sciencedirect.com/science/article/pii/S0013794417305799

  19. Chitosan–tripolyphosphate nanoparticles as Arrabidaea chica standardized extract carrier: synthesis, characterization, biocompatibility, and antiulcerogenic activity

    Directory of Open Access Journals (Sweden)

    Servat-Medina L

    2015-06-01

    Full Text Available Leila Servat-Medina,1,2 Alvaro González-Gómez,2,3 Felisa Reyes-Ortega,2 Ilza Maria Oliveira Sousa,1 Nubia de Cássia Almeida Queiroz,1 Patricia Maria Wiziack Zago,1 Michelle Pedrosa Jorge,1 Karin Maia Monteiro,1,4 João Ernesto de Carvalho,1 Julio San Román,2,3 Mary Ann Foglio1 1Chemical, Biological and Agricultural Pluridisciplinary Research Center-State University of Campinas (CPQBA-UNICAMP, Campinas-SP, Brazil; 2Biomaterials Group, Polymer Science and Technology Institute-Spanish National Research Council (ICTP-CSIC, 3CIBER-BBN, Centro de Investigación Biomédica en Red, Madrid, Spain; 4Department of Medical Clinics, Faculty of Medical Sciences, University of Campinas, Campinas-SP, Brazil Abstract: Natural products using plants have received considerable attention because of their potential to treat various diseases. Arrabidaea chica (Humb. & Bonpl. B. Verlot is a native tropical American vine with healing properties employed in folk medicine for wound healing, inflammation, and gastrointestinal colic. Applying nanotechnology to plant extracts has revealed an advantageous strategy for herbal drugs considering the numerous features that nanostructured systems offer, including solubility, bioavailability, and pharmacological activity enhancement. The present study reports the preparation and characterization of chitosan–sodium tripolyphosphate nanoparticles (NPs charged with A. chica standardized extract (AcE. Particle size and zeta potential were measured using a Zetasizer Nano ZS. The NP morphological characteristics were observed using scanning electron microscopy. Our studies indicated that the chitosan/sodium tripolyphosphate mass ratio of 5 and volume ratio of 10 were found to be the best condition to achieve the lowest NP sizes, with an average hydrodynamic diameter of 150±13 nm and a zeta potential of +45±2 mV. Particle size decreased with AcE addition (60±10.2 nm, suggesting an interaction between the extract’s composition

  20. Brain activity is related to individual differences in the number of items stored in auditory short-term memory for pitch: evidence from magnetoencephalography.

    Science.gov (United States)

    Grimault, Stephan; Nolden, Sophie; Lefebvre, Christine; Vachon, François; Hyde, Krista; Peretz, Isabelle; Zatorre, Robert; Robitaille, Nicolas; Jolicoeur, Pierre

    2014-07-01

    We used magnetoencephalography (MEG) to examine brain activity related to the maintenance of non-verbal pitch information in auditory short-term memory (ASTM). We focused on brain activity that increased with the number of items effectively held in memory by the participants during the retention interval of an auditory memory task. We used very simple acoustic materials (i.e., pure tones that varied in pitch) that minimized activation from non-ASTM related systems. MEG revealed neural activity in frontal, temporal, and parietal cortices that increased with a greater number of items effectively held in memory by the participants during the maintenance of pitch representations in ASTM. The present results reinforce the functional role of frontal and temporal cortices in the retention of pitch information in ASTM. This is the first MEG study to provide both fine spatial localization and temporal resolution on the neural mechanisms of non-verbal ASTM for pitch in relation to individual differences in the capacity of ASTM. This research contributes to a comprehensive understanding of the mechanisms mediating the representation and maintenance of basic non-verbal auditory features in the human brain. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Using an ACTIVE teaching format versus a standard lecture format for increasing resident interaction and knowledge achievement during noon conference: a prospective, controlled study

    Science.gov (United States)

    2014-01-01

    Background The traditional lecture is used by many residency programs to fulfill the mandate for regular didactic sessions, despite limited evidence to demonstrate its effectiveness. Active teaching strategies have shown promise in improving medical knowledge but have been challenging to implement within the constraints of residency training. We developed and evaluated an innovative structured format for interactive teaching within the residency noon conference. Methods We developed an ACTIVE teaching format structured around the following steps: assemble (A) into groups, convey (C) learning objectives, teach (T) background information, inquire (I) through cases and questions, verify (V) understanding, and explain (E) answer choices and educate on the learning points. We conducted a prospective, controlled study of the ACTIVE teaching format versus the standard lecture format, comparing resident satisfaction, immediate knowledge achievement and long-term knowledge retention. We qualitatively assessed participating faculty members’ perspectives on the faculty development efforts and the feasibility of teaching using the ACTIVE format. Results Sixty-nine internal medicine residents participated in the study. Overall, there was an improvement in perceived engagement using the ACTIVE teaching format (4.78 vs. 3.80, P teaching format (overall absolute score increase of 11%, P = 0.04) and a trend toward improvement in long-term knowledge retention. Faculty members felt adequately prepared to use the ACTIVE teaching format, and enjoyed teaching with the ACTIVE teaching format more than the standard lecture. Conclusions A structured ACTIVE teaching format improved resident engagement and initial knowledge, and required minimal resources. The ACTIVE teaching format offers an exciting alternative to the standard lecture for resident noon conference and is easy to implement. PMID:24985781

  2. Standard guide for conducting exfoliation corrosion tests in aluminum alloys

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1992-01-01

    1.1 This guide differs from the usual ASTM standard in that it does not address a specific test. Rather, it is an introductory guide for new users of other standard exfoliation test methods, (see Terminology G 15 for definition of exfoliation). 1.2 This guide covers aspects of specimen preparation, exposure, inspection, and evaluation for conducting exfoliation tests on aluminum alloys in both laboratory accelerated environments and in natural, outdoor atmospheres. The intent is to clarify any gaps in existent test methods. 1.3 The values stated in SI units are to be regarded as the standard. The inch-pound units given in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  3. {sup 226}Ra activity standardization by 4παβ(LS)-γ(NaI-Tl) anticoincidence counting

    Energy Technology Data Exchange (ETDEWEB)

    Silva, C.J. da; Poledna, R.; Santos, A.R.L.; Gomes, R.S., E-mail: carlos@ird.gov.br [Instituto de Radioproteção e Dosimetria (LNMRI/IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Laboratório Nacional de Metrologia das Radiações Ionizantes

    2017-07-01

    From a commercial supplier a solution containing {sup 226}Ra has been standardized at National Laboratory for Ionizing Radiation Metrology (LNMRI) for the first time using Liquid scintillation based measurement. The measurement methods are 4παβ-γ live-timed anticoincidence counting. The results obtained by anticoincidence counting were adopted as reference value and its combined uncertainty was 0.94 %. The agreement of this reference value with reference system with ionization chamber was 0.56 %. This standardization was made in order to reduce the uncertainty in {sup 226}Ra measurement in Brazil. (author)

  4. Non-destructive alpha-particle activation analysis of P, Cl, K and Ca in marine macro-alga samples using synthetic multielement reference material as comparative standard

    International Nuclear Information System (INIS)

    Iwata, Y.; Naitoh, H.; Suzuki, N.

    1992-01-01

    A Synthetic Reference Material (SyRM) composed with accurately known amounts of 12 elements has been prepared. The elemental composition of the SyRM is closely similar to that of marine macro-algae sample. The elemental composition of the SyRM was regulated by the starting materials used for the synthesis. The SyRM was used as a comparative standard for non-destructive alpha-particle activation analysis of marine macro-alga samples. P, Cl, K and Ca were determined simultaneously without correction for alpha range due to difference in the elemental composition between the analytical samples and the comparative standard. (author) 19 refs.; 4 tabs

  5. Internal-standard method for the determination of uranium, thorium, lanthanum and europium in carbonaceous shale and monazite by epithermal neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Shuenn-Gang; Tsai, Hui-Tuh; Wu, Shaw-Chii [Institute of Nuclear Energy Research, Lung-Tan (Taiwan, Republic of China)

    1981-10-03

    An internal-standard method was applied for the determination of uranium, thorium, lanthanum and europium is carbonaceous shale samples and monazite sand by epithermal neutron activation analysis using gold as an internal standard element. The samples were irradiated in a zero-power reactor at the Institute of Nuclear Energy Research and measured with a high-resolution Ge(Li) detector. The detection limit is 0.1 ppm for uranium and europium, 1 ppm for thorium, 5 ppm for lanthanum, and the realative error of all elements is within +-2.6%.

  6. Activity on non-destructive testing as constituent element of the quality management in accordance with ISO 9001:2000 standard at The Institute of Nuclear Physics, Kazakhstan

    International Nuclear Information System (INIS)

    Kadyrzhanov, K.K.; Kislitsin, S.B.; Ablanov, M.B.

    2004-01-01

    An increase of technical and public safety requirements for facilities of nuclear industries, an efficient quality control based on non-destructive testing (NDT) techniques is crucial. Therefore, Institute of Nuclear Physics (INP) through NDT Division makes efforts towards a competent NDT inspection of its facilities starting from research reactor of WWR-K type with a further activity according to the National Program for Development in Nuclear Industry. The additional objective is to harmonize the present codes and standards for Nuclear Industry as an integral part of the INP policy in a quality management according ISO 9001:2000 Standard. (author)

  7. Current global standards for chemical protective clothing: how to choose the right protection for the right job?

    Science.gov (United States)

    VAN WELY, Eric

    2017-01-01

    The first standards for chemical protective clothing (CPC) emerged mid to late 1980’s and have evolved since as most standards are revisited every 5 yr. Over the past years, we have also seen a strengthening of the chemical and worker protection legislation around the globe (various forms of REACH) but also protection of workers. The most prevalent standards originate under the auspices of the International Standards Organisation (ISO), European Committee for Standardisation (CEN) or under various US standards organisations (e.g. NFPA, ASTM). Protective clothing against hazardous materials is required in many of the professional and non-professional activities of everyday life. Effective and adequate protection is important in many scenarios from household (e.g. cleaning agents, peroxides, acids and bases, paints), to agricultural (e.g. fuel, pesticides), to medical (e.g. pharmaceuticals and active ingredients), to industrial production (e.g. petro-chemicals, chemicals, paints, adhesive and coatings) but also manufacturing of many products (e.g. light bulbs, cars, semi-conductors), during various emergency activities (e.g. boat, rail or road accidents as well as fire-fighting in an urban and industrial setting), and finally, military operations or response to incidents of terrorism. Nevertheless, CPC must remain the last line of defence whenever possible through a preference for less hazardous chemicals, less dangerous processes and handling operations, and by engineering controls to reduce and minimise human contact with the chemicals. This article provides information about the selection, use, care and maintenance (SUCAM) of protective clothing against chemical and microbiological hazards. PMID:29046493

  8. Field Demonstration of Active Desiccant Modules Designed to Integrate with Standard Unitary Rooftop Package Equipment - Final Report: Phase 3

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, J

    2004-03-15

    This report summarizes the investigation of two active desiccant module (ADM) pilot site installations initiated in 2001. Both pilot installations were retrofits at existing facilities served by conventional heating, ventilating, and air-conditioning (HVAC) systems that had encountered frequent humidity control, indoor air quality (IAQ), and other operational problems. Each installation involved combining a SEMCO, Inc., ADM (as described in Fischer and Sand 2002) with a standard packaged rooftop unit built by the Trane Company. A direct digital control (DDC) system integral to the ADM performed the dual function of controlling the ADM/rooftop combination and facilitating data collection, trending, and remote performance monitoring. The first installation involved providing preconditioned outdoor air to replace air exhausted from the large kitchen hood and bathrooms of a Hooters restaurant located in Rome, Georgia. This facility had previously added an additional rooftop unit in an attempt to achieve occupant comfort without success. The second involved conditioning the outdoor air delivered to each room of a wing of the Mountain Creek Inn at the Callaway Gardens resort. This hotel, designed in the ''motor lodge'' format with each room opening to the outdoors, is located in southwest Georgia. Controlling the space humidity always presented a serious challenge. Uncomfortable conditions and musty odors had caused many guests to request to move to other areas within the resort. This is the first field demonstration performed by Oak Ridge National Laboratory where significant energy savings, operating cost savings, and dramatically improved indoor environmental conditions can all be claimed as the results of a retrofit desiccant equipment field installation. The ADM/rooftop combination installed at the restaurant resulted in a reduction of about 34% in the electricity used by the building's air-conditioning system. This represents a reduction of

  9. Standard classification of uranium resources-an illustrative example

    International Nuclear Information System (INIS)

    Krishna, P.M.; Babitzke, H.R.; Curry, D.; Masters, C.D.; McCammon, R.B.; Noble, R.B.; Rodriguez, J.A.; Schanz, J.J.; Schreiber, H.W.

    1983-01-01

    An example illustrates the use of ASTM Standard E901-82, Classification System for Uranium Resources. The example demonstrates the dynamic nature of the process of classification and attests to the necessity of addressing both the aggregate needs of broad-scale resource planning and the specific needs of individual property evaluation. Problems that remain in fixing the classification of a given uranium resource include the uncertainty in estimating the quantity of undiscovered resources and resolving the differences that may exist in deciding when the drill-hole spacing is adequate to determine the tonnage and grade of discovered resources

  10. Standards development for fiber optic spectroscopic components for adverse environments

    Science.gov (United States)

    Saggese, Steven J.; Greenwell, Roger A.

    1994-09-01

    Optical fiber sensors are finding wider use in all types of applications involving adverse environments, including exposure to radiation. In order to effectively characterize and evaluate the performance of a fiber sensor system for a radiation environment, such as within a nuclear power plant or in a radioactive waste storage/disposal facility, it is beneficial to develop standard test procedures. Science & Engineering Associates (SEA) has developed two such procedures for the American Society for Testing and Materials (ASTM) which address the testing of optical fibers for remote Raman spectroscopic and broadband sensor applications in a steady state radiation environment.

  11. Kinetic and morphological differentiation of Ettringites in plain and blended Portland cements using Metakaolin and the ASTM C 452-68 test. Part I: kinetic differentiation

    Directory of Open Access Journals (Sweden)

    Talero, R.

    2008-12-01

    Full Text Available In this first part of the study, the results obtained in prior research with XRD and SEM, as well as the Le Chatelier-Ansttet test were confirmed with the ASTM C 452-68 test. To this end, 20%, 30% and 40% metakaolin (MK was added to ten Portland cements, six OPCs and four SRPCs. Both the ten plain PCs and the 30 metakaolin (MK blends were tested for two years under ASTM C 452-68 specifications, determining not only the percentage increase in length, ΔL(%, of the specimens, but also the sulphate content in the curing water. Other parameters studied included: chemical analysis of the cementitious materials used and specific properties of some of the cements tested.The experimental results, ΔL(% versus time, re-confirmed that the formation rate of ettringite from the reactive alumina, Al2O3r-, present in the pozzolan must be substantially higher than the formation rate of ettringite from the C3A present in the PC. This was verified by the variation of the sulphate content in the specimen curing water throughout the test. In light of those findings, in this article these two types of ettringite are denominated rapid forming ettringite or ett-rf, and slow forming ettringite or ett-lf.En esta Parte I de la investigación, se han logrado verificar mediante el ensayo ASTM C 452-68, los resultados obtenidos en anteriores investigaciones realizadas con DRX y SEM y el ensayo Le Chatelier-Ansttet. Para ello, a 10 cementos Portland –6 CPO y 4 CPRS– se les añadió 20%, 30% y 40% de metakaolín (MK. Tanto los 10 CP como los 30 de sus mezclas con metakaolín (MK, se ensayaron durante 2 años, mediante dicho método ASTM C 452-68, y a sus probetas no sólo se les determinó su incremento porcentual de longitud, ΔL(%, sino además, el contenido de sulfatos de sus aguas de conservación. Otras determinaciones complementarias fueron: análisis químico de los materiales cementiceos utilizados y propiedades específicas de algunos cementos ensayados

  12. Prediction methods for the calculation of the flammability properties of gases and vapors: CHETAH and ASTM software. Part 1. Esters and Ethers

    International Nuclear Information System (INIS)

    Gigante, L.; Dellavedova, M.; Pasturenzi, C.; Lunghi, A.; Cardillo, P.

    2008-01-01

    After the law by decree of the 12. June 2003, N 233 (ATEX Directive) and REACH regulation (Regulation EC n. 2907/2006 of the European Parliament), several industrial fields, also not chemical, need the flammability data for the substances used. Perhaps, many of these data, especially for compounds with not common uses, are not easy to collect. It would be helpful to provide prediction methods in order to calculate these data without any experimentation that sometimes results time consuming, expensive and practically impossible for all the commercial compounds. In this research the ASTM software CHETAH (CHEmical Thermodynamic And Hazard evaluation) has been used in order to compute the lower flammability limit (L i ), the limiting oxygen concentration (LOC, using nitrogen as inert gas) as a function of temperature, the adiabatic flame temperature T flame , the fundamental burning velocity (S u ), the quenching distance (Q d ), the minimum ignition energy (MIE) for esters and ethers, substances highly used in industry. [it

  13. Oxidación a alta temperatura de un acero ASTM A335 P92 en contacto con una mezcla de sales de

    OpenAIRE

    Jessica Rodríguez Pérez; Eduardo Santos Sánchez; Darío Yesid Peña Ballesteros; Anderson Sandoval Amador; Hugo Armando Estupiñán Durán

    2016-01-01

    En esta investigación se evaluó la oxidación del acero ASTM A335 P92 en una mezcla de sales 40% K2SO4 - 60% NaCl a temperaturas de 500ºC a 700ºC, a intervalos de 50°C con tiempos de exposición de 1, 3, 10, 30, 100 y 150 horas, utilizando la norma estandarizada por la Federación Europea de Corrosión. Se realizó análisis metalográfico y de dureza antes y después del ensayo para identificar el posible cambio estructural; se realizan pruebas de difracción de rayos X (DRX), microscopía electrónica...

  14. Damage characterization of an ASTM A 213 grade 91 tube after 116.000 h of service in a reforming plant

    International Nuclear Information System (INIS)

    Tonti, Andrea; Lega, Daniela; Antonini, Alessandra; Romitelli, Manuela; Alvino, Antonello

    2015-01-01

    ASTM A213 T91 steel is used in power plants and petrochemical industry, for long-term service components. The improved mechanical properties of grade 91 are strictly related to its specific microstructure: a tempered martensite matrix with fine precipitates embedded in. Despite low alloy heat resistant ferritic steels, that have a well known operational experience, T91 service performances are still faintly consolidated, because this material has serviced only in a limited number of plants, since the eighties. Most of the available data were obtained by laboratory tests on relatively short term creep strength and corrosion properties. The investigations reported in this paper represent an important opportunity to describe and better evaluate the damage evolution of the grade T91 steel after more than 100000 h of exposure in severe conditions (580 °C, 18–26 bar, combustion environment). Our results suggest that the steel suffered by different damage forms, which appear on definite portions of the tube cross section. The main degradation forms observed, in fact, into the tube bulk are both the martensite recovery and the microstructural evolution. This latter promoted mostly Laves phase precipitation and coarsening. On the other hand, both the outer and the inner wall side, suffered mainly by severe oxidation/carburization. Especially on the outer surface, the massive carbide precipitation has caused an evident loss of ductility so that the mechanical properties of the tube appear appreciably reduced. - Highlights: • ASTM A213 T91 steel is used in petrochemical industry, for long-term service components. • The investigations reported an evaluation of the damage evolution of the grade T91 steel. • Our results suggest that the steel suffered both the martensite recovery and the microstructural evolution. • The outer and the inner wall side, suffered mainly by severe oxidation/carburization. • Carbide precipitation caused loss of ductility so that the

  15. Effects of oxidation-nitridation in the presence of water vapor on ASTM A335 P92 steel using SEM-EDS and XPS characterization techniques

    Science.gov (United States)

    Orozco, J. C.; Kafarov, V.; Y Peña, D.; Alviz, A.

    2017-12-01

    This research studies the physical and chemical changes in steel ASTM A335 P92, produced from a typical refinery corrosion environment. The environment evaluated was oxidation-nitridation with the presence of water vapor. In this study five (5) exposure times were selected: 1, 20, 50, 100 and 200 hours; As well as two (2) analysis temperatures: 450 and 550°C. The working pressure used was one (1) atmosphere. Bearing in mind the kinetic study, the behaviour shown in ASTM A335 P92 steel describes an accelerated growth until 50 hours, after this time growth is less. For the tests carried out at 450°C, the kinetic constant was 2x10-8g2mm-4h-1, as well as for 550°C the calculated kinetic constant was 3.1×10-7g2mm-4h-1 through the SEM-EDS characterization techniques, it was possible to appreciate a good adhesion and homogeneity of the layers formed on the metal matrix until a time of exposure of 100 hours at 450 and 550°C, different from that evidenced to 200 hours of exposure where the layer formed near to the substrate showed detachment, this is attributed to the formation of hydroxides product of water vapor. Among the results obtained are the elemental composition, the presence of nitrides such as Si3N4, also NSiO2 and NSi2O, molybdenum oxides: MoO2 and MoO3 and iron oxides: FeO and Fe2O3 can be evidenced.

  16. Knee Flexion and Daily Activities in Patients following Total Knee Replacement: A Comparison with ISO Standard 14243

    Directory of Open Access Journals (Sweden)

    Markus A. Wimmer

    2015-01-01

    Full Text Available Walking is only one of many daily activities performed by patients following total knee replacement (TKR. The purpose of this study was to examine the hypotheses (a that subject activity characteristics are correlated with knee flexion range of motion (ROM and (b that there is a significant difference between the subject’s flexion/extension excursion throughout the day and the ISO specified input for knee wear testing. In order to characterize activity, the number of walking and stair stepping cycles, the time spent with dynamic and stationary activities, the number of activity sequences, and the knee flexion/extension excursion of 32 TKR subjects were collected during daily activity. Flexion/extension profiles were compared with the ISO 14243 simulator input profile using a level crossing classification algorithm. Subjects took an average of 3102 (range: 343–5857 walking cycles including 65 (range: 0–319 stair stepping cycles. Active and passive ROMs were positively correlated with stair walking time, stair step counts, and stair walking sequences. Simulated knee motion according to ISO showed significantly fewer level crossings at the flexion angles 20–40° and beyond 50° than those measured with the monitor. This suggests that implant wear testing protocols should contain more cycles and a variety of activities requiring higher knee flexion angles with incorporated resting/transition periods to account for the many activity sequences.

  17. Chitosan coatings onto polyethylene terephthalate for the development of potential active packaging material

    International Nuclear Information System (INIS)

    Zemljič, Lidija Fras; Tkavc, Tina; Vesel, Alenka; Šauperl, Olivera

    2013-01-01

    Highlights: ► The adsorption/desorption of chitosan onto PET plastic film was studied. ► Chitosan was reversible attached onto PET plastic films. ► Antimicrobial functionalized PET may provide potential active packaging material. - Abstract: In this paper advanced surface treatment of PET plastic film is presented for introduction of antimicrobial properties as a potential application for food (as for example meat) packaging material. Adsorption/desorption of chitosan onto PET plastic film surface was studied using several analytical techniques such as: X-Ray Photoelectron Spectroscopy (XPS), ATR-FTIR spectroscopy and titrations. Kinetic desorption of chitosan from PET surface was analysed by polyelectrolyte titration and spectrophotometric Ninhydrine reaction. Standard antimicrobial test ASTM E2149-01 was performed for functionalised PET materials in order to determine their antimicrobial properties; i. e. to measure the reductions of some of the meat pathogens; such as bacteria Salmonella enterica, Campylobacter spp., Escherichia coli, Listeria monocytogenes and fungi Candida albicans.

  18. Study of specific pharmacological activity of standardized composition of bee product substances for treatment of urogenital system

    Directory of Open Access Journals (Sweden)

    V. M. Koval

    2017-10-01

    Full Text Available Introduction. The work presents review of the data literature, which indicate the prospects of creation new highly efficient drugs for the treatment of chronic prostatitis and prostate gland adenoma based bioactive standardized substances of bee products, including powdered honey (PH, propolis phenolic hydrophobic drug (PPHD and bee pollen (BP. Materials and methods. Results of discussion of preclinical pharmacological studies of standardized substances of bee products composition – PH, PPHD and BP for the treatment of specified pathology is given in the experimental part. Results. It was found that the most pronounced anti-inflammatory effect on the level 40 % the mixture of APIs (PH, PPHD and BP detects at a dose of 100 mg/kg in relation to the reference drug – trianom capsules in doses of 100 and 130 mg/kg. Conclusions. Usage of bee products is grounded in creation of the new drug on their basis in the form of standardized substances of bee products composition –PH, PPHD and BP for chronic prostatitis and prostate gland adenoma. It was found that the most pronounced anti-inflammatory effect on 40 % the mixture of APIs (PH, PPHD and BP detects at a dose of 100 mg/kg. It was established that the composition of standard substances of bee products – PH, PPHD and BP at a dose of 100 mg/kg shows a more pronounced specific pharmacological effect in comparison to the reference product – trianom capsules at doses of 100 and 130 mg/kg, which positively affect the course of the pilot prostatitis in male rats caused by dichloroethyl.

  19. Instrumental neutron activation analysis of geochemical samples by k{sub 0} standardization method using short lived nuclides

    Energy Technology Data Exchange (ETDEWEB)

    Oura, Yasuji; Kanzaki, Chinatsu; Ebihara, Mitsuru [Tokyo Metropolitan Univ., Graduate School of Science, Tokyo (Japan)

    2003-03-01

    Mg, Al, Ca, Ti, V, and Mn contents in geochemical and cosmochemical samples were analyzed by both k{sub 0} standardization INAA and conventional INAA by a comparison method. The contents of Mg, Al, and Mn by k{sub 0} method were consistent with recommended values and ones by comparison methods. For Ti and V their values are slightly higher than recommended ones. The values by k{sub 0} method were reliable within {+-}10%. (author)

  20. A mixed-method study of the efficacy of physical activity consultation as an adjunct to standard smoking cessation treatment among male smokers in Malaysia.

    Science.gov (United States)

    Lee, Yuin Yi; Khoo, Selina; Morris, Tony; Hanlon, Clare; Wee, Lei-Hum; Teo, Eng Wah; Adnan, Yuhanis

    2016-01-01

    This study examined the effectiveness of using Physical Activity Consultation (PAC) as an addition to the standard smoking cessation treatment in Malaysia. We explored participants' experiences in terms of physical activity and smoking abstinence with the combined PAC and smoking cessation intervention. Walk-in smokers from a local smoking cessation clinic volunteered for the 8-week intervention program, while undergoing standard smoking cessation treatment. In Week 1, a facilitator conducted a face-to-face intervention to explore participants' involvement in physical activity and helped to set physical activity strategies and goals for participants to increase physical activity levels. Participants were provided with follow-up phone calls at Weeks 3 and 6. Participants answered questionnaires that measured smoking withdrawal (Shiffman-Jarvik Withdrawal Scale), cessation self-efficacy (Cessation Self-efficacy Questionnaire), physical activity involvement (International Physical Activity Questionnaire), and mood (Brunel Mood Scale) upon recruitment, at post-intervention and at follow-up 3 months after the intervention ended. Participants also responded to interviews about their experiences with the PAC and smoking cessation treatment at post-intervention and at 3-month follow-up. Seven participants completed the program until follow-up. All were successfully abstinent. Only two participants increased physical activity levels, whereas others maintained their physical activity levels or showed slight decreases. Several themes were identified in this study, including participants' experiences with withdrawal symptoms, smoking cessation self-efficacy, triggers to smoking cessation, thoughts on standard smoking cessation treatment in Malaysia, physical activity involvement, mood, and thoughts and beliefs on combining smoking cessation and physical activity. This study suggests PAC was helpful in maintaining or increasing the overall physical activity levels of