WorldWideScience

Sample records for assessing ventricular size

  1. Potential usefulness of an artificial neural network for assessing ventricular size

    International Nuclear Information System (INIS)

    Fukuda, Haruyuki; Nakajima, Hideyuki; Usuki, Noriaki; Saiwai, Shigeo; Miyamoto, Takeshi; Inoue, Yuichi; Onoyama, Yasuto.

    1995-01-01

    An artificial neural network approach was applied to assess ventricular size from computed tomograms. Three layer, feed-forward neural networks with a back propagation algorithm were designed to distinguish between three degree of enlargement of the ventricles on the basis of patient's age and six items of computed tomographic information. Data for training and testing the neural network were created with computed tomograms of the brains selected at random from daily examinations. Four radiologists decided by mutual consent subjectively based on their experience whether the ventricles were within normal limits, slightly enlarged, or enlarged for the patient's age. The data for training was obtained from 38 patients. The data for testing was obtained from 47 other patients. The performance of the neural network trained using the data for training was evaluated by the rate of correct answers to the data for testing. The valid solution ratio to response of the test data obtained from the trained neural networks was more than 90% for all conditions in this study. The solutions were completely valid in the neural networks with two or three units at the hidden layer with 2,200 learning iterations, and with two units at the hidden layer with 11,000 learning iterations. The squared error decreased remarkably in the range from 0 to 500 learning iterations, and was close to a contrast over two thousand learning iterations. The neural network with a hidden layer having two or three units showed high decision performance. The preliminary results strongly suggest that the neural network approach has potential utility in computer-aided estimation of enlargement of the ventricles. (author)

  2. Assessing ventricular size: is subjective evaluation accurate enough? New MRI-based normative standards for 19-year-olds

    Energy Technology Data Exchange (ETDEWEB)

    Aukland, Stein Magnus [Haukeland University Hospital, Department of Radiology, Bergen (Norway); University of Bergen, Institute of Surgical Sciences, Section for Radiology, Bergen (Norway); Odberg, Morten Duus [University of Bergen, Institute of Clinical Medicine, Section for Paediatrics, Bergen (Norway); Gunny, Roxanna; Chong, W.K. [Great Ormond Street Hospital for Children, Department of Radiology, London (United Kingdom); Eide, Geir Egil [Haukeland University Hospital, Centre for Clinical Research, Bergen (Norway); University of Bergen, Department of Public Health and Primary Health Care, Bergen (Norway); Rosendahl, Karen [University of Bergen, Institute of Surgical Sciences, Section for Radiology, Bergen (Norway); Great Ormond Street Hospital for Children, Department of Radiology, London (United Kingdom)

    2008-12-15

    To create new standards for radiological indices of dilated ventricles and to compare these with subjectively assessed ventricular size. One hundred healthy controls (54 females), birth weight above 3,000 g, were followed throughout childhood as part of a longitudinal study of ex-prematures. All had a 3 Tesla brain magnetic resonance scan at age 17-20, and the following measurements were performed: biparietal and occipitofrontal diameters, width and depth of the frontal and occipital horns, diameter of the third ventricle and the frontal sub-arachnoid space. Ventricular size was judged subjectively by two neuroradiologists as being normal, or mildly, moderately or severely dilated. Head circumference was 31 mm higher for males than for females (95% confidence interval (CI) 25-28, p < 0.001). Similar, ventricular size except for the depth of the right frontal horn was larger for male; however, the observed differences were partly accounted for by the larger head circumference. Normative sex specific standards for different cerebral measurements were presented as mean and ranges and additional 2.5, 10, 50, 90, 97.5 percentiles. The mean depth of the left ventricle was larger than the right for males, with an observed difference of 0.6 mm in male (95% CI 0.2-0.9, p = 0.005). The mean width of the left ventricle was larger than the right for females, with an observed difference of 0.4 mm in male (95% CI 0.1-0.7, p = 0.018). Two subjects were judged to have moderately and 36 to have mildly dilated ventricles by observer one, while figures for observer two were one and 14. Overall, the two observers agreed on 15 having either mild or moderate dilatation (kappa 0.43). For both sexes, the mean depth of the frontal horns as well as of the larger occipital horns differed significantly between the no dilatation and the mild/moderate dilatation groups. In our unselected cohort of healthy 19-year-olds, a high total of 14% was diagnosed to have dilated cerebral ventricles when

  3. Assessing ventricular size: is subjective evaluation accurate enough? New MRI-based normative standards for 19-year-olds

    International Nuclear Information System (INIS)

    Aukland, Stein Magnus; Odberg, Morten Duus; Gunny, Roxanna; Chong, W.K.; Eide, Geir Egil; Rosendahl, Karen

    2008-01-01

    To create new standards for radiological indices of dilated ventricles and to compare these with subjectively assessed ventricular size. One hundred healthy controls (54 females), birth weight above 3,000 g, were followed throughout childhood as part of a longitudinal study of ex-prematures. All had a 3 Tesla brain magnetic resonance scan at age 17-20, and the following measurements were performed: biparietal and occipitofrontal diameters, width and depth of the frontal and occipital horns, diameter of the third ventricle and the frontal sub-arachnoid space. Ventricular size was judged subjectively by two neuroradiologists as being normal, or mildly, moderately or severely dilated. Head circumference was 31 mm higher for males than for females (95% confidence interval (CI) 25-28, p < 0.001). Similar, ventricular size except for the depth of the right frontal horn was larger for male; however, the observed differences were partly accounted for by the larger head circumference. Normative sex specific standards for different cerebral measurements were presented as mean and ranges and additional 2.5, 10, 50, 90, 97.5 percentiles. The mean depth of the left ventricle was larger than the right for males, with an observed difference of 0.6 mm in male (95% CI 0.2-0.9, p = 0.005). The mean width of the left ventricle was larger than the right for females, with an observed difference of 0.4 mm in male (95% CI 0.1-0.7, p = 0.018). Two subjects were judged to have moderately and 36 to have mildly dilated ventricles by observer one, while figures for observer two were one and 14. Overall, the two observers agreed on 15 having either mild or moderate dilatation (kappa 0.43). For both sexes, the mean depth of the frontal horns as well as of the larger occipital horns differed significantly between the no dilatation and the mild/moderate dilatation groups. In our unselected cohort of healthy 19-year-olds, a high total of 14% was diagnosed to have dilated cerebral ventricles when

  4. Accuracy and interobserver concordance of echocardiographic assessment of right ventricular size and systolic function: a quality control exercise.

    Science.gov (United States)

    Ling, Lee Fong; Obuchowski, Nancy A; Rodriguez, Leonardo; Popovic, Zoran; Kwon, Deborah; Marwick, Thomas H

    2012-07-01

    Accurate assessment of right ventricular (RV) size (RVS) and RV systolic function (RVSF) is vital in the management of various conditions, but their assessment is challenging using echocardiography. The aim of this study was to determine the accuracy and interobserver concordance of qualitative and quantitative RV echocardiography. Fifteen readers evaluated RV function in 12 patients (360 readings) who underwent echocardiography and cardiac magnetic resonance for RV assessment. Readers qualitatively estimated RVS and RVSF as normal, mild, moderate, or severe and then reassessed quantitatively by adding RV dimensions, fractional area change, S', tricuspid annular plane systolic excursion, and RV index of myocardial performance. Cardiac magnetic resonance was used as the reference standard for grading RVS and RVSF. Quantitative measurements increased accuracy and interreader agreement compared to qualitative assessment alone, especially in normal categories. Readers' accuracy for diagnosing normal and severe RVS increased from 38% to 78% (P = .001) and from 70% to 97% (P = .018), and readers' accuracy for diagnosing normal and mild RVSF increased from 52% to 84% (P value of 0.40 to 0.77 (fair to good agreement) for RVS and from 0.43 to 0.66 (moderate to good agreement) for RVSF. Visual estimation of RVS and RVSF is inaccurate and has wide interobserver variability. Quantitation improves accuracy and reliability, especially in distinction of normal and abnormal. The reliability of mild and moderate grades remains inadequate, and further guidance is needed for the classification of abnormal categories. Copyright © 2012 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

  5. Cardiothoracic ratio may be misleading in the assessment of right- and left-ventricular size in patients with repaired tetralogy of Fallot

    International Nuclear Information System (INIS)

    Śpiewak, M.; Małek, Ł.A.; Biernacka, E.K.; Kowalski, M.; Michałowska, I.; Hoffman, P.; Miśko, J.; Demkow, M.; Rużyłło, W.; Marczak, M.

    2014-01-01

    Aim: To assess the relationship between cardiothoracic ratio (CTR) and ventricular and atrial volumes in patients with repaired tetralogy of Fallot (TOF). Materials and methods: Patients with repaired TOF undergoing cardiac magnetic resonance (CMR) and chest radiography within 1 day were included (n = 82; median age: 24.7 years, interquartile range: 21.5–35.9). The CTR was obtained from upright posteroanterior chest roentgenograms. Analyses of CMR images and radiographs were performed in a blinded fashion. Results: There were 35.1% (13/37) of patients with normal CTR (<0.5) who had severe right ventricular (RV) dilatation. There were six patients (13.3%, 6/45) with high CTR with both normal RV and left-ventricular (LV) volumes. CTR did not correlate with either RV or LV volumes but showed a weak correlation with right- and left-atrial volumes (r = 0.43, p = 0.0001; r = 0.27, p = 0.01, respectively). CTR ≥0.5 showed poor ability in the identification of severe RV dilatation (sensitivity: 61.8%, specificity: 50%). The combination of CTR and signs of RV enlargement on lateral radiographs did not improve the diagnostic accuracy of any of those parameters alone. Conclusion: CTR in patients with repaired TOF reflected atrial rather than ventricular dilatation. The use of CTR or lateral radiographs in patients with repaired TOF may lead to false conclusions concerning ventricular size. - Highlights: • Cardiothoracic ratio did not correlate with either right- or left-ventricular volumes. • Cardiothoracic ratio reflected atrial rather than ventricular dilatation. • Normal cardiothoracic ratio did not exclude severe right ventricular dilatation. • Neither RVEF nor LVEF showed correlation with cardiothoracic ratio

  6. Performance of two-dimensional Doppler echocardiography for the assessment of infarct size and left ventricular function in rats

    Directory of Open Access Journals (Sweden)

    Nozawa E.

    2006-01-01

    Full Text Available Although echocardiography has been used in rats, few studies have determined its efficacy for estimating myocardial infarct size. Our objective was to estimate the myocardial infarct size, and to evaluate anatomic and functional variables of the left ventricle. Myocardial infarction was produced in 43 female Wistar rats by ligature of the left coronary artery. Echocardiography was performed 5 weeks later to measure left ventricular diameter and transverse area (mean of 3 transverse planes, infarct size (percentage of the arc with infarct on 3 transverse planes, systolic function by the change in fractional area, and diastolic function by mitral inflow parameters. The histologic measurement of myocardial infarction size was similar to the echocardiographic method. Myocardial infarct size ranged from 4.8 to 66.6% when determined by histology and from 5 to 69.8% when determined by echocardiography, with good correlation (r = 0.88; P < 0.05; Pearson correlation coefficient. Left ventricular diameter and mean diastolic transverse area correlated with myocardial infarct size by histology (r = 0.57 and r = 0.78; P < 0.0005. The fractional area change ranged from 28.5 ± 5.6 (large-size myocardial infarction to 53.1 ± 1.5% (control and correlated with myocardial infarct size by echocardiography (r = -0.87; P < 0.00001 and histology (r = -0.78; P < 00001. The E/A wave ratio of mitral inflow velocity for animals with large-size myocardial infarction (5.6 ± 2.7 was significantly higher than for all others (control: 1.9 ± 0.1; small-size myocardial infarction: 1.9 ± 0.4; moderate-size myocardial infarction: 2.8 ± 2.3. There was good agreement between echocardiographic and histologic estimates of myocardial infarct size in rats.

  7. Influence of left ventricular hypertrophy on infarct size and left ventricular ejection fraction in ST-elevation myocardial infarction

    International Nuclear Information System (INIS)

    Małek, Łukasz A.; Śpiewak, Mateusz; Kłopotowski, Mariusz; Petryka, Joanna; Mazurkiewicz, Łukasz; Kruk, Mariusz; Kępka, Cezary; Miśko, Jolanta; Rużyłło, Witold; Witkowski, Adam

    2012-01-01

    Background: Left ventricular hypertrophy (LVH) predisposes to larger infarct size, which may be underestimated by the left ventricular ejection fraction (LVEF) due to supranormal systolic performance often present in patients with LVH. The aim of the study was to compare infarct size and LVEF in patients with ST-segment elevation myocardial infarction (STEMI) and increased left ventricular mass on cardiac magnetic resonance (CMR). Methods: The study included unselected group of 52 patients (61 ± 11 years, 69% male) with first STEMI who had CMR after median 5 days from the onset of the event. Left ventricular hypertrophy (LVH) was defined as left ventricular mass index exceeding 95th percentile of references values for age and gender. Infarct size was assessed with means of late gadolinium enhancement (LGE). Results: LVH was found in 16 patients (31%). In comparison to the rest of the group, patients with LVH had higher absolute and relative infarct mass (p = 0.002 and p = 0.02, respectively). LVH was related to higher prevalence of microvascular obstruction and myocardial haemorrhage and higher number of LV segments with transmural necrosis (p = 0.02, p = 0.01 and p = 0.01, respectively). Despite marked difference in the infarct size between both studied subgroups there was no difference in LVEF and mean number of dysfunctional LV segments. Conclusions: Patients with LVH undergoing STEMI have larger infarct size underestimated by the LV systolic performance in comparison to patients without LVH.

  8. Routine Chest X-ray: Still Valuable for the Assessment of Left Ventricular Size and Function in the Era of Super Machines?

    Science.gov (United States)

    Morales, Maria-Aurora; Prediletto, Renato; Rossi, Giuseppe; Catapano, Giosuè; Lombardi, Massimo; Rovai, Daniele

    2012-01-01

    The development of technologically advanced, expensive techniques has progressively reduced the value of chest X-ray in clinical practice for the assessment of left ventricular (LV) dilatation and dysfunction. Although controversial data are reported on the role of this widely available technique in cardiac assessment, it is known that the cardio-thoracic ratio is predictive of risk of progression in the NYHA Class, hospitalization, and outcome in patients with LV dysfunction. This study aimed to evaluate the reliability of the transverse diameter of heart shadow [TDH] by chest X-ray for detecting LV dilatation and dysfunction as compared to Magnetic Resonance Imaging (MRI) performed for different clinical reasons. In 101 patients, TDH was measured in digital chest X-ray and LV volumes and ejection fraction (EF) by MRI, both exams performed within 2 days. A direct correlation between TDH and end-diastolic volumes (r = .75, Pvalues of 14.5 mm in females identified LV end-diastolic volumes >150 mL (sensitivity: 82%, specificity: 69%); in males a cut-off value of 15.5 mm identified LV end-diastolic volumes >210 mL (sensitivity: 84%; specificity: 72%). A negative relation was found between TDH and LVEF (r = -.54, Pvalues of TDH discriminated patients with LV systolic dysfunction - LVEF <35% (sensitivity and specificity: 67% and 57% in females; 76% and 59% in males, respectively). Chest X-ray may still be considered a reliable technique in predicting LV dilatation by the accurate measurement of TDH as compared to cardiac MRI. Technologically advanced, expensive, and less available imaging techniques should be performed on the basis of sound clinical requests.

  9. Mitral regurgitation in myocardial infarction complicated by heart failure, left ventricular dysfunction, or both: prognostic significance and relation to ventricular size and function

    DEFF Research Database (Denmark)

    Amigoni, Maria; Meris, Alessandra; Thune, Jens Jakob

    2007-01-01

    AIMS: Mitral regurgitation (MR) confers independent risk in patients with acute myocardial infarction. We utilized data from the VALsartan In Acute myocardial iNfarcTion echo study to relate baseline MR to left ventricular (LV) size, shape, and function, and to assess the relationship between...

  10. Effect of endurance exercise training on left ventricular size and remodeling in older adults with hypertension.

    Science.gov (United States)

    Turner, M J; Spina, R J; Kohrt, W M; Ehsani, A A

    2000-04-01

    It is not known whether exercise training can induce a reduction of blood pressure (BP) and a regression of left ventricular hypertrophy (LVH) in older hypertensive subjects. This study was designed to determine whether endurance exercise training, by lowering BP, can induce regression of LVH and left ventricular (LV) concentric remodeling in older hypertensive adults. We studied 11 older adults with mild to moderate hypertension (BP 152.0 +/- 2.5/91.3 +/- 1.5 mm Hg, mean +/- SE), 65.5 +/- 1.2 years old, who exercised for 6.8 +/- 3.8 months. Seven sedentary hypertensive (BP 153 +/- 3/89 +/- 2 mm Hg) subjects, 68.5 +/- 1 years old, served as controls. LV size and geometry and function were assessed with the use of two-dimensional echocardiography. Exercise training increased aerobic power by 16% (p hypertension.

  11. Ventricular kinetic energy may provide a novel noninvasive way to assess ventricular performance in patients with repaired tetralogy of Fallot.

    Science.gov (United States)

    Jeong, Daniel; Anagnostopoulos, Petros V; Roldan-Alzate, Alejandro; Srinivasan, Shardha; Schiebler, Mark L; Wieben, Oliver; François, Christopher J

    2015-05-01

    Ventricular kinetic energy measurements may provide a novel imaging biomarker of declining ventricular efficiency in patients with repaired tetralogy of Fallot. Our purpose was to assess differences in ventricular kinetic energy with 4-dimensional flow magnetic resonance imaging between patients with repaired tetralogy of Fallot and healthy volunteers. Cardiac magnetic resonance, including 4-dimensional flow magnetic resonance imaging, was performed at rest in 10 subjects with repaired tetralogy of Fallot and 9 healthy volunteers using clinical 1.5T and 3T magnetic resonance imaging scanners. Right and left ventricular kinetic energy (KERV and KELV), main pulmonary artery flow (QMPA), and aortic flow (QAO) were quantified using 4-dimensional flow magnetic resonance imaging data. Right and left ventricular size and function were measured using standard cardiac magnetic resonance techniques. Differences in peak systolic KERV and KELV in addition to the QMPA/KERV and QAO/KELV ratios between groups were assessed. Kinetic energy indices were compared with conventional cardiac magnetic resonance parameters. Peak systolic KERV and KELV were higher in patients with repaired tetralogy of Fallot (6.06 ± 2.27 mJ and 3.55 ± 2.12 mJ, respectively) than in healthy volunteers (5.47 ± 2.52 mJ and 2.48 ± 0.75 mJ, respectively), but were not statistically significant (P = .65 and P = .47, respectively). The QMPA/KERV and QAO/KELV ratios were lower in patients with repaired tetralogy of Fallot (7.53 ± 5.37 mL/[cycle mJ] and 9.65 ± 6.61 mL/[cycle mJ], respectively) than in healthy volunteers (19.33 ± 18.52 mL/[cycle mJ] and 35.98 ± 7.66 mL/[cycle mJ], respectively; P tetralogy of Fallot. Quantification of ventricular kinetic energy in patients with repaired tetralogy of Fallot is a new observation. Future studies are needed to determine whether changes in ventricular kinetic energy can provide earlier evidence of ventricular dysfunction and guide future medical and

  12. Left ventricular mass in borderline hypertension assessed by echo cardiography

    International Nuclear Information System (INIS)

    Mezzasalma, L.; Ghione, S.; Palonebo, C.

    1989-01-01

    The relationship between clinical measurement of blood pressure (BP) and left ventricular hypertrophy in arterial hypertension appears to be weak in most studies. On the contrary, stronger correlations with target organ damage in general, and left ventricular hypertrophy in particular, have been reported for blood pressure measurements obtained by ambulatory monitoring; this finding may indicate a possible role for blood pressure response to naturally occurring stresses in determining left ventricular hypertrophy. Aim of this study was to investigate, in 18 patients with borderline arterial hypertension, the relationships between echocardiographically assessed left ventricular mass and, respectively, casual BP and BP responses to some standardized stress tests. Only three patients had a diastolic wall thickness of the interventricular septum and of the posterior wall ≥1.2 cm and none had a pathologically increased left ventricular mass index. The following statistically significant correlations were found: casual diastolic BP vs. left ventricular mass index (r=0.53, p<0.02), systolic BP response to bicycle exercise test vs. left ventricular mass index (r=0.55, p<0.05). Multiple regression analysis showed that almost fifty percent of the variability of left ventricular mass index could be predicted by these two BP measurements. These findings suggest that besides the chronically increased afterload, also the transient hypertensive responses to naturally occuring physical stresses may have a role in determining the extent of cardiac structural changes in borderline hypertensive patients. In addition, they indicate a direct relation between left ventricular mass and blood pressure levels also in borderline hypertension, as previously shown for established hypertension, despite the fact that left ventricular hypertrophy represents only an occasional finding in early stages of hypertension

  13. Assessment of right ventricular systolic function by tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Kjærgaard, Jesper

    2012-01-01

    This thesis summarizes a series of studies performed in order to assess the clinical usefulness of a novel echocardiographic technology that allows non-invasive assessment of regional right ventricular myocardial velocities and deformation: tissue Doppler echocardiography. While the technology...... is a promising tool for improving our understanding of right ventricular hemodynamics, several aspects of the technology must be evaluated. The accuracy and reproducibility of the technology is evaluated in vitro, and normal values, impact of changes in loading of the right ventricle, response to exercise...... on right ventricular hemodynamics: pulmonary embolism, Arrhythmogenic right ventricular cardiomyopathy and pulmonary regurgitation, the latter in an animal model. The conclusions of the thesis are: Color tissue Doppler echocardiography accurately measures velocities, SR and strain in vitro. No systematic...

  14. Assessment of inter-atrial, inter-ventricular, and atrio-ventricular interactions in tetralogy of Fallot patients after surgical correction. Insights from two-dimensional speckle tracking and three-dimensional echocardiography.

    Science.gov (United States)

    Abd El Rahman, Mohamed; Raedle-Hurst, Tanja; Rentzsch, Axel; Schäfers, Hans-Joachim; Abdul-Khaliq, Hashim

    2015-10-01

    We aimed to assess biatrial size and function, interactions on atrial and ventricular levels, and atrio-ventricular coupling in patients after tetralogy of Fallot repair. A total of 34 patients with a mean age of 20.9±9 years, and 35 healthy controls, underwent two-dimensional speckle tracking echocardiography for ventricular and atrial strain measurements and real-time three-dimensional echocardiography to assess ventricular and atrial volumes. When compared with controls, tetralogy of Fallot patients had significantly reduced right atrial peak atrial longitudinal strain (ptetralogy of Fallot group, left ventricular ejection fraction was negatively related to the right ventricular end-systolic volume normalised to body surface area (r=-0.62, ptetralogy of Fallot patients, biatrial dysfunction exists and can be quantified via two-dimensional speckle tracking echocardiography as well as real-time three-dimensional echocardiography. Different forms of interactions on atrial and ventricular levels are evident among such cohorts.

  15. Assessment of left ventricular global function

    International Nuclear Information System (INIS)

    Breuel, H.-P.; Baehre, M.

    1985-01-01

    Radionuclide ventriculography (RNV), i.e. noninvasive evaluation of left venticular performance following the application of radionuclides has had a major impact on many aspects of cardiology and has proven its clinical value and reliability in the last few years. This article deals mainly with the changes in global left ventricular function. The clinical applications of RNV for coronary artery diseases and valvular heart diseases are described. (Auth.)

  16. Noninvasive assessment of right ventricular wall motion by radionuclide cardioangiography

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Uehara, Toshiisa; Naito, Hiroaki; Hayashida, Kohei; Kozuka, Takahiro

    1981-01-01

    Radionuclide cardioangiography is a useful method to evaluate the left ventricular wall motion in various heart diseases. It has been also attempted to assess the right ventricular wall motion simultaneously by radionuclide method. In this study, using the combination of first-pass (RAO 30 0 ) and multi-gate (LAO 40 0 ) method, the site of right vetricle was classified in five. (1 inflow, 2 sinus, 3 outflow, 4 septal, 5 lateral) and the degree of wall motion was classified in four stages (dyskinesis, akinesis, hypokinesis, normal) according to the AHA committee report. These methods were applied clinically to forty-eight patients with various heart diseases. In the cases with right ventricular pressure or volume overload such as COLD, pulmonary infarction, the right ventricle was dilated and the wall motion was reduced in all portions. Especially, in the cases with right ventricular infarction, the right ventricular wall motion was reduced in the infarcted area. The findings of radionuclide method were in good agreement with those of contrast right ventriculography or echocardiography. In conclusion, radionuclide cardioangiography is a useful and noninvasive method to assess not only the left but also the right ventricular wall motion. (author)

  17. Indications for CSF shunting in normal pressure hydrocephalus following subarachnoid hemorrhage with lateral ventricular size change on cine-MR

    Energy Technology Data Exchange (ETDEWEB)

    Fujitsuka, Mitsuyuki [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    2002-09-01

    To clarify the indications for cerebrospinal fluid (CSF) shunting in normal pressure hydrocephalus (NPH) following subarachnoid hemorrhage (SAH), the author investigated changes in the pulsatile brain motions during a cardiac cycle in 17 cases with ventriculomegaly following SAH on cardiac gated cine MR images comparing with those in 50 normal adults. In 15 of these seventeen cases, the lateral ventricles not only constricted immediately following the R-wave related to brain expansion but also expanded paradoxically over the initial size during a cardiac diastole. These patterns were different from those of normal adults, and eleven of them showed excellent response to CSF shunting. Theses findings in ventricular motion during a cardiac cycle indicate that the forceful intraventricular CSF flows and stagnancy expand the ventricular walls causing compression of the surrounding brain against the skull. In the remaining two, the lateral ventricles only constricted immediately following the R-wave and the ventricular size change was similar to those of normal adults, and they were diagnosed as not requiring CSF shunting. Assessing ventricular size change on cine-MR enables non-invasive differentiation of NPH from other form of ventriculomegaly, and evaluation of the benefit of CSF shunting is also possible by this technique preoperatively. (author)

  18. Sympathetic stimulation alters left ventricular relaxation and chamber size.

    Science.gov (United States)

    Burwash, I G; Morgan, D E; Koilpillai, C J; Blackmore, G L; Johnstone, D E; Armour, J A

    1993-01-01

    Alterations in left ventricular (LV) contractility, relaxation, and chamber dimensions induced by efferent sympathetic nerve stimulation were investigated in nine anesthetized open-chest dogs in sinus rhythm. Supramaximal stimulation of acutely decentralized left stellate ganglia augmented heart rate, LV systolic pressure, and rate of LV pressure rise (maximum +dP/dt, 1,809 +/- 191 to 6,304 +/- 725 mmHg/s) and fall (maximum -dP/dt, -2,392 +/- 230 to -4,458 +/- 482 mmHg/s). It also reduced the time constant of isovolumic relaxation, tau (36.5 +/- 4.8 to 14.9 +/- 1.1 ms). Simultaneous two-dimensional echocardiography recorded reductions in end-diastolic and end-systolic LV cross-sectional chamber areas (23 and 31%, respectively), an increase in area ejection fraction (32%), and increases in end-diastolic and end-systolic wall thicknesses (14 and 13%, respectively). End-systolic and end-diastolic wall stresses were unchanged by stellate ganglion stimulation (98 +/- 12 to 95 +/- 9 dyn x 10(3)/cm2; 6.4 +/- 2.4 to 2.4 +/- 0.3 dyn x 10(3)/cm2, respectively). Atrial pacing to similar heart rates did not alter monitored indexes of contractility. Dobutamine and isoproterenol induced changes similar to those resulting from sympathetic neuronal stimulation. These data indicate that when the efferent sympathetic nervous system increases left ventricular contractility and relaxation, concomitant reductions in systolic and diastolic dimensions of that chamber occur that are associated with increasing wall thickness such that LV wall stress changes are minimized.

  19. Ventricular dysfunction in children with obstructive sleep apnea: radionuclide assessment

    International Nuclear Information System (INIS)

    Tal, A.; Leiberman, A.; Margulis, G.; Sofer, S.

    1988-01-01

    Ventricular function was evaluated using radionuclide ventriculography in 27 children with oropharyngeal obstruction and clinical features of obstructive sleep apnea. Their mean age was 3.5 years (9 months to 7.5 years). Conventional clinical assessment did not detect cardiac involvement in 25 of 27 children; however, reduced right ventricular ejection fraction (less than 35%) was found in 10 (37%) patients (mean: 19.5 +/- 2.3% SE, range: 8-28%). In 18 patients wall motion abnormality was detected. In 11 children in whom radionuclide ventriculography was performed before and after adenotonsillectomy, right ventricular ejection fraction rose from 24.4 +/- 3.6% to 46.7 +/- 3.4% (P less than 0.005), and in all cases wall motion showed a definite improvement. In five children, left ventricular ejection fraction rose greater than 10% after removal of oropharyngeal obstruction. It is concluded that right ventricular function may be compromised in children with obstructive sleep apnea secondary to adenotonsillar hypertrophy, even before clinical signs of cardiac involvement are present

  20. Fetal cerebral biometry: normal parenchymal findings and ventricular size

    International Nuclear Information System (INIS)

    Garel, C.

    2005-01-01

    Assessing fetal cerebral biometry is one means of ascertaining that the development of the fetal central nervous system is normal. Norms have been established on large cohorts of fetuses by sonographic and neurofetopathological studies. Biometric standards have been established in MR in much smaller cohorts. The purpose of this paper is to analyse methods of measuring a few parameters in MR [biparietal diameter (BPD), fronto-occipital diameter (FOD), length of the corpus callosum (LCC), atrial diameter, transverse cerebellar diameter, height, anteroposterior diameter and surface of the vermis] and to compare US and MR in the assessment of fetal cerebral biometry. (orig.)

  1. An Echocardiographic Study of Left Ventricular Size and Cardiac Function in Adolescent Females with Anorexia Nervosa.

    Science.gov (United States)

    Escudero, Carolina A; Potts, James E; Lam, Pei-Yoong; De Souza, Astrid M; Mugford, Gerald J; Sandor, George G S

    2016-01-01

    This retrospective case-control study investigated cardiac dimensions and ventricular function in female adolescents with anorexia nervosa (AN) compared with controls. Echocardiographic measurements of left ventricular (LV) dimensions, LV mass index, left atrial size and cardiac index were made. Detailed measures of systolic and diastolic ventricular function were made including tissue Doppler imaging. Patients were stratified by body mass index ≤10th percentile (AN ≤ 10th) and >10th percentile (AN > 10th). Ninety-five AN patients and 58 controls were included. AN and AN ≤ 10th groups had reduced LV dimensions, LV mass index, left atrial size and cardiac index compared with controls. There were no differences between groups in measures of systolic function. Measures of diastolic tissue Doppler imaging were decreased in AN and AN ≤ 10th. No differences in echocardiographic measurements existed between controls and AN > 10th. Female adolescents with AN have preserved systolic function and abnormalities of diastolic ventricular function. AN ≤ 10th may be a higher risk group. Copyright © 2015 John Wiley & Sons, Ltd and Eating Disorders Association.

  2. The effect of acute mechanical left ventricular unloading on ovine tricuspid annular size and geometry.

    Science.gov (United States)

    Malinowski, Marcin; Wilton, Penny; Khaghani, Asghar; Brown, Michael; Langholz, David; Hooker, Victoria; Eberhart, Lenora; Hooker, Robert L; Timek, Tomasz A

    2016-09-01

    Left ventricular assist device (LVAD) implantation may alter right ventricular shape and function and lead to tricuspid regurgitation. This in turn has been reported to be a determinant of right ventricular (RV) failure after LVAD implantation, but the effect of mechanical left ventricular (LV) unloading on the tricuspid annulus is unknown. The aim of the study was to provide insight into the effect of LVAD support on tricuspid annular geometry and dynamics that may help to optimize LV unloading with the least deleterious effect on the right-sided geometry. In seven open-chest anaesthetized sheep, nine sonomicrometry crystals were implanted on the right ventricle. Additional nine crystals were implanted around the tricuspid annulus, with one crystal at each commissure defining three separate annular regions: anterior, posterior and septal. Left ventricular unloading was achieved by connecting a cannula in the left atrium and the aorta to a continuous-flow pump. The pump was used for 15 min at a full flow of 3.8 ± 0.3 l/min. Epicardial echocardiography was used to assess the degree of tricuspid insufficiency. Haemodynamic, echocardiographic and sonomicrometry data were collected before and during full unloading. Tricuspid annular area, and the regional and total perimeter were calculated from crystal coordinates, while 3D annular geometry was expressed as the orthogonal distance of each annular crystal to the least squares plane of all annular crystals. There was no significant tricuspid regurgitation observed either before or during LV unloading. Right ventricular free wall to septum diameter increased significantly at end-diastole during unloading from 23.6 ± 5.8 to 26.3 ± 6.5 mm (P = 0.009), but the right ventricular volume, tricuspid annular area and total perimeter did not change from baseline. However, the septal part of the annulus significantly decreased its maximal length (38.6 ± 8.1 to 37.9 ± 8.2 mm, P = 0.03). Annular contraction was not altered. The

  3. Serial Doppler echocardiographic assessment of left and right ventricular performance after a first myocardial infarction

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Poulsen, S H

    2001-01-01

    We sought to investigate the relation between left ventricular (LV) and right ventricular (RV) function assessed with the Doppler-derived myocardial performance index (MPI), to assess serial changes, and to investigate the prognostic value of biventricular assessment of cardiac function after a f...

  4. Quantitative thallium-201 myocardial imaging in assessing right ventricular pressure in patients with congenital heart defects

    International Nuclear Information System (INIS)

    Rabinovitch, M.; Fischer, K.C.; Treves, S.

    1981-01-01

    Thallium-201 myocardial scintigraphy was performed in patients with congenital heart defects to determine whether, by quantification of right ventricular isotope uptake, one could assess the degree of right ventricular hypertrophy and so predict the level of right ventricular pressure. It is shown that quantitative analysis of myocardial imaging with thallium-201 is of use clinically in patients with congenital heart defects, in assessing the severity of pulmonary stenosis or the presence of pulmonary artery hypertension. (author)

  5. Right ventricular function: methodologic and clinical considerations in noninvasive scintigraphic assessment

    International Nuclear Information System (INIS)

    Manno, B.V.; Iskandrian, A.S.; Hakki, A.H.

    1984-01-01

    Right ventricular function plays an important role in many cardiac disorders. Changes in left ventricular function, right ventricular afterload and preload, cardiac medications and ischemia may affect right ventricular function. Radionuclide ventriculography permits quantitative assessment of regional and global function of the right ventricle. This assessment can be made at rest, during exercise or after pharmacologic interventions. The overlap between right ventricle and right atrium is a major limitation for gated scintigraphic techniques. The use of imaging with newer short-lived radionuclides may permit more accurate and reproducible assessment of right ventricular function by means of the first pass method. Further work in areas related to improvement of techniques and the impact of right ventricular function on prognosis is needed

  6. Regression in left ventricular mass after aortic valve replacement for chronic aortic regurgitation is unrelated to prosthetic valve size.

    Science.gov (United States)

    Brown, Morgan L; Schaff, Hartzell V; Suri, Rakesh M; Li, Zhuo; Sundt, Thoralf M; Dearani, Joseph A; Enriquez-Sarano, Maurice

    2011-08-01

    We examined the role of prosthesis-patient mismatch on left ventricular mass regression after aortic valve replacement for chronic aortic valve regurgitation. We selected patients who had complete preoperative and follow-up echocardiograms with measurement of left ventricular mass. Patients were excluded who had moderate or greater aortic valve stenosis, concomitant coronary artery bypass grafting, or mitral valve procedures. Patients' mean age was 55 ± 17 years; 21% were female. The mean preoperative indexed left ventricular mass was 150 ± 45 g/m(2). Patients with mildly (n = 44; mean indexed mass, 126 ± 15 g/m(2)), moderately (n = 31; mean indexed mass, 168 ± 11 g/m(2)), or severely (n = 15; mean indexed mass, 241 ± 34 g/m(2)) increased preoperative indexed left ventricular mass, were similar, except for lower ejection fractions, larger end-diastolic dimensions, and larger ventricular wall thicknesses in the severely enlarged group (P regression was unrelated to labeled valve size, prosthesis-patient mismatch, or measured indexed effective aortic valve area. A greater preoperative indexed left ventricular mass (P regression. Despite having greater left ventricular mass regression, patients with severe preoperative indexed left ventricular mass did not return to normal values (mean, 142 ± 25 g/m(2)). Left ventricular mass regression after aortic valve replacement for chronic aortic regurgitation is unrelated to indexed prosthetic valve area. Although incomplete, regression is greatest in patients with the largest preoperative indexed left ventricular mass. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  7. Comparing impedance cardiography and echocardiography in the assessment of reduced left ventricular systolic function

    DEFF Research Database (Denmark)

    Kaszuba, Elzbieta; Scheel, Sergej; Odeberg, Håkan

    2013-01-01

    An early and accurate diagnosis of chronic heart failure is a big challenge for a general practitioner. Assessment of left ventricular function is essential for the diagnosis of heart failure and the prognosis. A gold standard for identifying left ventricular function is echocardiography...

  8. Assessment of ventricular function by radionuclide ventriculography in hyperthyroidism

    International Nuclear Information System (INIS)

    Dong Weiyu; He Pinyu; Zhuang Weite

    1996-01-01

    Left ventricular(LV) and right ventricular(RV) function were determined using radionuclide ventriculography in 50 patients with hyperthyroidism. LVEF, LVPFR, SV of the hyperthyroidism group were decreased in comparison with the normal group (P<0.01), whereas CO of the hyperthyroidism patients were higher than that of normal (P<0.01). Except LVPER, the LVEF, SV had significant difference between two groups. Compared to normal group, RVEF, RVPER, RVPFR were also decreased (P<0.01). Besides 30 cases of the hyperthyroidism were examined by impedance cardiogram (ICG) and impedance pulmonary rheogram (IPR), all showed closely correlation with the parameters determined by ventriculography. There was the involvement of right ventricular function insufficiency, especially in ejection phase. When compared with pre-therapy, pos-therapy cases showed significant improvement in EF, PER, PFR of left and right ventricular

  9. Contemporary Assessment of Left Ventricular Diastolic Function in Older Adults

    DEFF Research Database (Denmark)

    Shah, Amil M.; Claggett, Brian; Kitzman, Dalane

    2017-01-01

    Background: Although age-Associated changes in left ventricular diastolic function are well recognized, limited data exist characterizing measures of diastolic function in older adults, including both reference ranges reflecting the older adult population and prognostically relevant values...

  10. Stable right ventricular size and function during short-term follow-up in patients with pulmonary regurgitation after tetralogy of Fallot repair

    International Nuclear Information System (INIS)

    Śpiewak, M.; Małek, Ł.A.; Petryka, J.; Biernacka, E.K.; Hoffman, P.; Demkow, M.; Miśko, J.; Rużyłło, W.

    2013-01-01

    Aim: To assess changes in ventricular size and function over time in conservatively treated adult patients with repaired tetralogy of Fallot (TOF) and significant pulmonary regurgitation (PR). Materials and methods: Patients with repaired TOF who had undergone more than one cardiac magnetic resonance study were identified. To confine the cause of ventricular size and function deviation to PR, patients with residual ventricular septal defect, more than mild regurgitation at a valve other than the pulmonary valve, and known coronary artery disease were excluded. Results: The final analysis included 27 adults with PR fraction >20%. During a follow-up of mean 2.1 ± 0.8 years, there was no change in right ventricular (RV) end-diastolic volume (EDV; 162.1 ± 27.6 versus 164 ± 29.6 ml/m 2 , p = 0.5). Left ventricular (LV) EDV showed a small decrease (85.1 ± 16.2 versus 81.5 ± 14.1 ml/m 2 , p = 0.02). The mean PR fraction, PR volume, and peak RV outflow tract gradient did not change. Additionally, both RV ejection fraction (EF) and LVEF remained stable over the follow-up period (48.1 ± 6.5 versus 48.4 ± 6.7%, p = 0.83, and 57.3 ± 5.4 versus 57.2 ± 5.1 %, p = 0.91, respectively). Only two asymptomatic patients (7.4% of the study group) developed symptoms and the remaining did not deteriorate. Conclusion: The RVEDV, RVEF, and LVEF remained stable over a mean follow-up of approximately 2 years in the majority of adult patients after TOF repair with significant PR and a wide range of RVEDV

  11. Ventricular arrhythmia burst is an independent indicator of larger infarct size even in optimal reperfusion in STEMI

    NARCIS (Netherlands)

    van der Weg, Kirian; Majidi, Mohamed; Haeck, Joost D. E.; Tijssen, Jan G. P.; Green, Cynthia L.; Koch, Karel T.; Kuijt, Wichert J.; Krucoff, Mitchell W.; Gorgels, Anton P. M.; de Winter, Robbert J.

    2016-01-01

    We hypothesized that ventricular arrhythmia (VA) bursts during reperfusion phase are a marker of larger infarct size despite optimal epicardial and microvascular perfusion. 126 STEMI patients were studied with 24h continuous, 12-lead Holter monitoring. Myocardial blush grade (MBG) was determined and

  12. Patterns of ventricular dysfunction in patients receiving cardiotoxic chemotherapy as assessed with gated blood pool imaging

    International Nuclear Information System (INIS)

    Spies, S.M.; Parikh, S.R.; Spies, W.G.; Zimmer, A.M.; Silverstein, E.A.

    1989-01-01

    Clinical concern over significant cardiotoxicity of commonly employed chemotherapeutic regimens is a common indication for gated blood pool imaging. The authors have undertaken a review of 102 patients referred for such evaluation during a 14-month period. Ventricular ejection fractions, cine displays, and phase analysis were performed on each patient study. Approximately one-third of the cases showed significant abnormalities in wall motion or global ejection fraction. Many abnormal cases had isolated left ventricular findings, while fewer had isolated right ventricular findings. Left ventricular wall motion abnormalities were often focal. The patterns of ventricular dysfunction in patients receiving cardiotoxic chemotherapy are diverse, and awareness of the various possibilities is important for accurate clinical assessment of these patients

  13. Videodensitometric assessment of right and left ventricular functions by digital subtraction angiography

    International Nuclear Information System (INIS)

    Ikeda, Hisao; Yoshiga, Osamu; Shibao, Keigo

    1987-01-01

    Intravenous digital subtraction (DS) ventriculography was performed in a series of 50 patients with heart diseases to determine right and left ventricular volumes and systolic indices. Right ventricular volume and right ventricular ejection fraction obtained by DS ventriculography were well correlated with those by geometric methods. In 43 patients with left ventricular ejection fraction of 55 % or greater, end-diastolic volume, stroke volume, and ejection fraction in the right ventricle did not differ from those in the left ventricle ; however, both the 1/3 ejection fraction and the peak ejection rate of the right ventricle were significantly lower than those of the left ventricle, suggesting the different modes of left and right ventricular contraction. In the other seven patients with chronic left ventricular failure, right ventricular systolic function may be preserved, even when left ventricular function is severely impaired. Digital subtraction ventriculography has proved to be a simple, useful method in the quanlitative and quantitative assessments of the right and left ventricles. (Namekawa, K.)

  14. Assessment of the left ventricular function with the nuclear stethoscope

    Energy Technology Data Exchange (ETDEWEB)

    Tarkowska, A.; Adam, W.E.; Bitter, F.

    1980-08-01

    The evaluation of the left ventricular function with the Nuclear Stethoscope was performed on 27 patients with heart diseases. The reproducibility of the measurements was good. Repetitions of EF, ER and EDV estimations yielded errors of 2.63%, 1.45% and 0.31%. The comparison with the results of camera ventriculography showed a good agreement of EF, contraction velocity parameters and relaxation velocity parameters, with a cor. coeff. of greater or equal to 0.750. A particularly high correlation was found between the NS EF and NS ER (r = 0.968). It was concluded that the Nuclear Stethoscope provides a reliable evaluation of left ventricular function.

  15. Assessment of the left ventricular function with the nuclear stethoscope

    International Nuclear Information System (INIS)

    Tarkowska, A.; Adam, W.E.; Bitter, F.

    1980-01-01

    The evaluation of the left ventricular function with the Nuclear Stethoscope was performed on 27 patients with heart diseases. The reproducibility of the measurements was good. Repetitions of EF, ER and EDV estimations yielded errors of 2.63%, 1.45% and 0.31%. The comparison with the results of camera ventriculography showed a good agreement of EF, contraction velocity parameters and relaxation velocity parameters, with a cor. coeff. of greater or equal to 0.750. A particularly high correlation was found between the NS EF and NS ER (r = 0.968). It was concluded that the Nuclear Stethoscope provides a reliable evaluation of left ventricular function. (orig.) [de

  16. Assessment of right ventricular function using gated blood pool single photon emission computed tomography in inferior myocardial infarction with or without hemodynamically significant right ventricular infarction

    International Nuclear Information System (INIS)

    Takahashi, Masaharu

    1992-01-01

    Right ventricular function was assessed using gated blood pool single photon emission computed tomography (GSPECT) in 10 normal subjects and 14 patients with inferior myocardial infarction. Three-dimensional backbround subtraction was achieved by applying an optimal cut off level. The patient group consisted of 6 patients with definite hemodynamic abnormalities indicative of right ventricular infarction (RVI) and 8 other patients with significant obstructive lesion at the proximal portion of right coronary artery without obvious hemodynamic signs of RVI. Right ventricular regional wall motion abnormalities were demonstrated on GSPECT functional images and the indices of right ventricular function (i.e the right ventricular ejection fraction (RVEF), the right ventricular peak ejection rate (RVPER) and the right ventricular peak filling rate (RVPFR)) were significantly reduced in the patient group, not only in the patients with definite RVI but also in those without hemodynamic signs of RVI, even in the absence of definite hemodynamic signs, when the proximal portion of right coronary artery is obstructed. It is concluded that GSPECT is reliable for the assessment of right ventricular function and regional wall motion, and is also useful for the diagnosis of RVI. (author)

  17. Radionuclide stroke count ratios for assessment of right and left ventricular volume overload in children

    International Nuclear Information System (INIS)

    Parrish, M.D.; Graham, T.P. Jr.; Born, M.L.; Jones, J.P.; Boucek, R.J. Jr.; Artman, M.; Partain, C.L.

    1983-01-01

    The ratio of left ventricular to right ventricular stroke counts measured by radionuclide angiography has been used in adults to estimate the severity of left-sided valvular regurgitation. The validation of this technique in children for assessment of right and left ventricular volume overload is reported herein. Radionuclide stroke count ratios in 60 children aged 0.5 to 19 years (mean 11) were determined. Based on their diagnoses, the patients were divided into 3 groups: (1) normal--40 patients with no shunts or valvular regurgitation, (2) left ventricular volume overload--13 patients with mitral or aortic regurgitation, or both, and (3) right ventricular volume overload--7 patients, 2 with severe tricuspid regurgitation, 3 with atrial septal defects, and 2 with total anomalous pulmonary venous drainage. The radionuclide stroke count ratio clearly differentiated these groups (p less than 0.05): normal patients had a stroke count ratio of 1.04 +/- 0.17 (mean +/- 1 standard deviation), the left ventricular volume overload group had a stroke count ratio of 2.43 +/- 0.86, and the right ventricular volume overload group had a stroke count ratio of 0.44 +/- 0.17. In 22 of our 60 patients, radionuclide stroke count ratios were compared with cineangiographic stroke volume ratios, resulting in a correlation coefficient of 0.88. It is concluded that radionuclide ventriculography is an excellent tool for qualitative and quantitative assessment of valvular regurgitation in children

  18. Aortopulmonary collateral flow is related to pulmonary artery size and affects ventricular dimensions in patients after the fontan procedure.

    Directory of Open Access Journals (Sweden)

    Heiner Latus

    Full Text Available BACKGROUND: Aortopulmonary collaterals (APCs are frequently found in patients with a single-ventricle (SV circulation. However, knowledge about the clinical significance of the systemic-to-pulmonary shunt flow in patients after the modified Fontan procedure and its potential causes is limited. Accordingly, the aim of our study was to detect and quantify APC flow using cardiovascular magnetic resonance (CMR and assess its impact on SV volume and function as well as to evaluate the role of the size of the pulmonary arteries in regard to the development of APCs. METHODS: 60 patients (mean age 13.3 ± 6.8 years after the Fontan procedure without patent tunnel fenestration underwent CMR as part of their routine clinical assessment that included ventricular functional analysis and flow measurements in the inferior vena cava (IVC, superior vena cava (SVC and ascending aorta (Ao. APC flow was quantified using the systemic flow estimator: (Ao - (IVC + SVC. Pulmonary artery index (Nakata index was calculated as RPA + LPA area/body surface area using contrast enhanced MR angiography. The patient cohort was divided into two groups according to the median APC flow: group 1 0.495 l/min/m(2. RESULTS: Group 1 patients had significant smaller SV enddiastolic (71 ± 16 vs 87 ± 25 ml/m(2; p=0.004 and endsystolic volumes (29 ± 11 vs 40 ± 21 ml/m(2; p=0.02 whereas ejection fraction (59 ± 9 vs 56 ± 13%; p=0.38 differed not significantly. Interestingly, pulmonary artery size showed a significant inverse correlation with APC flow (r=-0.50, p=0.002. CONCLUSIONS: Volume load due to APC flow in Fontan patients affected SV dimensions, but did not result in an impairment of SV function. APC flow was related to small pulmonary artery size, suggesting that small pulmonary arteries represent a potential stimulus for the development of APCs.

  19. Simple area-based measurement for multidetector computed tomography to predict left ventricular size

    International Nuclear Information System (INIS)

    Schlett, Christopher L.; Kwait, Dylan C.; Mahabadi, Amir A.; Hoffmann, Udo; Bamberg, Fabian; O'Donnell, Christopher J.; Fox, Caroline S.

    2010-01-01

    Measures of left ventricular (LV) mass and dimensions are independent predictors of morbidity and mortality. We determined whether an axial area-based method by computed tomography (CT) provides an accurate estimate of LV mass and volume. A total of 45 subjects (49% female, 56.0 ± 12 years) with a wide range of LV geometry underwent contrast-enhanced 64-slice CT. LV mass and volume were derived from 3D data. 2D images were analysed to determine LV area, the direct transverse cardiac diameter (dTCD) and the cardiothoracic ratio (CTR). Furthermore, feasibility was confirmed in 100 Framingham Offspring Cohort subjects. 2D measures of LV area, dTCD and CTR were 47.3 ± 8 cm 2 , 14.7 ± 1.5 cm and 0.54 ± 0.05, respectively. 3D-derived LV volume (end-diastolic) and mass were 148.9 ± 45 cm 3 and 124.2 ± 34 g, respectively. Excellent inter- and intra-observer agreement were shown for 2D LV area measurements (both intraclass correlation coefficients (ICC) = 0.99, p 0.27). Compared with traditionally used CTR, LV size can be accurately predicted based on a simple and highly reproducible axial LV area-based measurement. (orig.)

  20. Right ventricular function assessment in single LAD lesion patients ...

    African Journals Online (AJOL)

    Rania Gaber

    2015-10-09

    Oct 9, 2015 ... Doppler method in patients with single LAD lesion. Methods: The patient group was ... Results: The right ventricular tissue Doppler parameters (Sm, E, A, E/A ratio, IVA, E/E00) of the patients group were significantly .... cardial interaction effect of tethered LV anterior myocardium. Mittal et al. reported that Left ...

  1. Quantitative assessment of regional left ventricular motion using endocardial landmarks

    NARCIS (Netherlands)

    C.J. Slager (Cornelis); T.E.H. Hooghoudt (Ton); P.W.J.C. Serruys (Patrick); J.C.H. Schuurbiers (Johan); J.H.C. Reiber (Johan); G.T. Meester (Geert); P.D. Verdouw (Pieter); P.G. Hugenholtz (Paul)

    1986-01-01

    textabstractIn this study the hypothesis is tested that the motion pattern of small anatomic landmarks, recognizable at the left ventricular endocardial border in the contrast angiocardiogram, reflects the motion of the endocardial wall. To verify this, minute metal markers were inserted in the

  2. Normal ventricular size and changes with age in pediatric groups on computed tomography

    International Nuclear Information System (INIS)

    Nakada, Yoshitaka; Nose, Tadao; Enomoto, Takao; Maki, Yutaka

    1980-01-01

    The purpose of this report is to determine the normal value of the ventricular size on CT, snd analyze its changes with age in normal pediatric group. Materials and Methods: We searched through our 240 normal pediatric CT film files, aged 4 months to 14 years. Scans were performed on Hitachi CT-II scanner, using 10 mm collimation. Results: 1. The width of the third ventricle showed the same value in all pediatric groups, the mean value of its being 4.8 mm (SD 1.3 mm). 2. Bicaudate cerebroventricular indexes of the anterior horns of lateral ventricles (interecarlate distance/transverse diameter of the brain x100) were 15.3 in infants under one year, 13.8 in the age of one year and 12.7 in the children over two years. The indexes were almost the same in old age group over the age of three years. 3. The upper limit of the normal inverse cella media index (minium width of cella media/transverse diameter of the brain x100) was 31. Therefore the cases with the index above this range can be diagnosed as hydrocephalic. 4. The shape of the anterior horns of lateral ventricles was Y-shaped in infants under one year. II-shaped (paralied shaped) in the age of 1 - 12 years, and again it was Y-shaped in the group over 12 years. 5. In the age group under one year, the temporal horns of the lateral ventricles were visualized in about 60% cases, while the figure decreased to 20% in the older group. (author)

  3. Assessment of right ventricular afterload in mitral valve diseases with radionuclide angiography

    International Nuclear Information System (INIS)

    Shimizu, Mitsuharu; Nakagawa, Tomio; Kohno, Yoshihiro; Kuroda, Masahiro; Takeda, Yoshihiro; Hiraki, Yoshio; Nagaya, Isao; Senoh, Yoshimasa; Teramoto, Shigeru

    1991-01-01

    Right ventricular function at rest and during exercise was studied in 33 patients with mitral valve disease by equilibrium gated radionuclide angiography using 99m Tc in vivo labeled red blood cells. Radionuclide measurements of right ventricular ejection fraction (RVEF) were correlated with mean pulmonary arterial pressure (mPAP). RVEF decreased significantly with exercise. There was no significant correlation between RVEF at rest and mPAP. However, mPAP showed significant negative correlation with RVEF during exercise and with the changes of RVEF from rest to exercise. It is concluded that RVEF during exercise in mitral valve disease is affected by right ventricular afterload, and the measurements of RVEF at rest and during exercise by equilibrium gated radionuclide angiography is useful to assess right ventricular afterload. (author)

  4. Prognostic significance of radionuclide-assessed right ventricular function in dilated cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, Akira; Nishimura, Tsunehiko; Uehara, Toshiisa; Shimonagata, Tsuyoshi; Kumita, Shinichiro; Ogawa, Youji; Nagata, Seiki; Miyatake, Kunio [National Cardiovascular Center, Suita, Osaka (Japan)

    1991-09-01

    To assess the prognostic significance of right ventricular function in dilated cardiomyopathy (DCM), we studied consecutive 57 DCM patients. There were 41 men and 16 women, whose mean age was 48 years (range 3-68 years). The mean left ventricular ejection fraction (LVEF) in all patients was 29{+-}11%, and the mean interval from the onset of symptom of cardiac failure (CHF history) was 4 years (range 0-33 years). With follow-up of 3.8 years, five patients had died until the first year, and 14 had died until the third year. By using multivariate regression analysis, there were no prognostic significance in clinical parameters such as age, CHF history, sex, atrial fibrillation, except for NYHA class, and medication at the third year. In survival curves according to Kaplan-Meier method, right ventricular ejection fraction (RVEF) and mean pulmonary artery (PA) had predictive value (p<0.05), while LVEF did not. The patients with RVEF<45% had poor survival rate compared to those with RVEF{>=}45%. The patients with RVEF<45% showed lower LVEF and left ventricular end-systolic volume index. RVEF may offer prognostic predictive value through the effect of not only mean PA but also left ventricular parameter. In conclusion, radionuclide assessment of right ventricular function should be valuable for the prognostic evaluation of DCM patients. (author).

  5. Prognostic significance of radionuclide-assessed right ventricular function in dilated cardiomyopathy

    International Nuclear Information System (INIS)

    Ohno, Akira; Nishimura, Tsunehiko; Uehara, Toshiisa; Shimonagata, Tsuyoshi; Kumita, Shinichiro; Ogawa, Youji; Nagata, Seiki; Miyatake, Kunio

    1991-01-01

    To assess the prognostic significance of right ventricular function in dilated cardiomyopathy (DCM), we studied consecutive 57 DCM patients. There were 41 men and 16 women, whose mean age was 48 years (range 3-68 years). The mean left ventricular ejection fraction (LVEF) in all patients was 29±11%, and the mean interval from the onset of symptom of cardiac failure (CHF history) was 4 years (range 0-33 years). With follow-up of 3.8 years, five patients had died until the first year, and 14 had died until the third year. By using multivariate regression analysis, there were no prognostic significance in clinical parameters such as age, CHF history, sex, atrial fibrillation, except for NYHA class, and medication at the third year. In survival curves according to Kaplan-Meier method, right ventricular ejection fraction (RVEF) and mean pulmonary artery (PA) had predictive value (p<0.05), while LVEF did not. The patients with RVEF<45% had poor survival rate compared to those with RVEF≥45%. The patients with RVEF<45% showed lower LVEF and left ventricular end-systolic volume index. RVEF may offer prognostic predictive value through the effect of not only mean PA but also left ventricular parameter. In conclusion, radionuclide assessment of right ventricular function should be valuable for the prognostic evaluation of DCM patients. (author)

  6. The application of phase analysis of gated myocardial perfusion imaging to assess left ventricular mechanical dyssynchrony in cardiovascular disease

    International Nuclear Information System (INIS)

    Wang Jianfeng; Wang Yuetao

    2013-01-01

    Left ventricular mechanical dyssynchrony is closely related to the severity of cardiovascular disease, it is essential to assess left ventricular mechanical dyssynchrony accurately for early prediction of adverse cardiac events and prognosis assessment of the cardiac resynchronization therapy. As a new technology to assess left ventricular mechanical dyssynchrony, the phase analysis of gated myocardial perfusion imaging (GMPI) can get both quantitative indicators of regional myocardial perfusion, evaluation of regional myocardial viability and scar tissue, as well as quantitative analysis of left ventricular function and left ventricular mechanical synchrony, it has broad application prospects in cardiovascular disease to assess left ventricular mechanical dyssynchrony and prognosis assessment. This review mainly described the applications of GMPI phase analysis in the cardiovascular disease. (authors)

  7. Applications of magnetic resonance imaging in the assessment of left ventricular dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Beacock, David John

    2002-07-01

    This thesis has described the use of Magnetic Resonance Imaging (MRI) in the investigation of left ventricular dimensions and systolic function. This has been performed in conditions of left ventricular dysfunction, in congestive cardiac failure and following anterior myocardial infarction. The reproducibility of measurements of left ventricular dimensions using MRI has been presented. Such measurements were shown to be reproducible between different MRI studies of normal volunteers and patients with congestive heart failure. Furthermore, measurements from different MRI studies obtained from two commercially different systems were reproducible for the same subject groups. Ventricular dimensions and systolic function was evaluated in adult normal volunteers of different ages. Although left ventricular volumes and mass remained unchanged, detailed studies of the systolic images revealed significant differences between the two age groups. Differences in left ventricular cavity volumes and mass between patients with congestive heart failure and age-matched normal volunteers were also investigated. Left ventricular volumes and myocardial mass were assessed in a group of patients following anterior myocardial infarction. End-systolic volume was significantly increased compared to age-matched volunteers, but no changes in end-diastolic volume or myocardial mass was observed. Serial re-evaluation of these patients revealed no other changes over the subsequent six months. All these patients were treated with optimal medical therapy (thrombolysis, aspirin, beta-blockade and angiotensin converting enzyme inhibition). Thus, the use of this therapy may attenuate the process of left ventricular remodelling. Regional wall thickness was measured in the post-infarct patients. Wall thickening was significantly reduced both in the infarcted regions and in myocardium remote to the infarction. In contrast to previous echocardiographic studies, no 'hypercontractility' was

  8. Correlation of radiological assessment of congestive heart failure with left ventricular end-diastolic pressure

    International Nuclear Information System (INIS)

    Herman, P.G.; Kahn, A.; Kallman, C.E.; Rojas, K.A.; Bodenheimer, M.M.

    1988-01-01

    Left ventricular end-diastolic pressure (LVEDP) has been considered a reliable indicator of left ventricular function. The purpose of this study was to correlate the radiologic assessment of congestive heart failure with LVEDP. The population of the study consisted of 85 consecutive cases in four ranges of LVEDP ( 24). The PA chest radiographs obtained 1 day prior to cardiac catherization were assessed for radiological evidence of congestive heart failure and were graded from normal to abnormal (0-3). The results will be summarized in the authors' presentation. The discordance of radiological assessment of congestive heart failure in patients with elevated LVEDP will be discussed in light of recent advances in pathophysiologic understanding of left ventricular function and the impact of new classes of drugs in the management of these patients

  9. Mental Condition and Ventricular Size in Arrested Hydrocephalus: an Analysis of 29 Shunt‐independent Children

    NARCIS (Netherlands)

    HOLTZER, G.J.; de LANGE, S.A.; ORBAAN, I.J.C.; GELSEMA, R.

    1971-01-01

    textabstractMeasurement of the diameter of the ventricular system, in a series of 29 patients with arrested hydrocephalus who had become shunt‐independent, showed that enlargement of the ventricles does not necessarily play a part in the arrest of hydrocephalus, for in many of these cases the

  10. Quantitative assessment of left ventricular systolic wall thickening using multidetector computed tomography

    DEFF Research Database (Denmark)

    Kristensen, Thomas S; Kofoed, Klaus F; Møller, Daniel V

    2009-01-01

    BACKGROUND: Multidetector computed tomography (MDCT) of the heart provides both anatomical and functional information. The objective of this study was to evaluate the accuracy of quantitative assessment of left ventricular contractile function in relation to two-dimensional transthoracic echocard......BACKGROUND: Multidetector computed tomography (MDCT) of the heart provides both anatomical and functional information. The objective of this study was to evaluate the accuracy of quantitative assessment of left ventricular contractile function in relation to two-dimensional transthoracic...... echocardiography (TTE). MATERIALS AND METHODS: Sixty-four patients with known or suspected coronary artery disease underwent ECG-gated 64-slice MDCT and TTE. Regional left ventricular contractile function was measured by percent systolic wall thickening (SWT) in 16 myocardial segments using MDCT, and compared...

  11. Left ventricular synchrony assessed by phase analysis of gated myocardial perfusion SPECT imaging in healthy subjects

    International Nuclear Information System (INIS)

    Wang Yuetao; Wang Jianfeng; Yang Minfu; Niu Rong

    2013-01-01

    Objective: To investigate the value of Cedars-Sinai quantitative gated SPECT (QGS) phase analysis for left ventricular synchrony assessment in healthy subjects. Methods: Seventy-four healthy subjects (41 males, 33 females,average age: (60±13) years) underwent both rest and exercise 99 Tc m -MIBI G-MPI. QGS software was used to analyze the reconstructed rest gated SPECT images automatically, and then the parameters of left ventricular synchrony including phase bandwidth (BW) and phase standard deviation (SD) were obtained. The influences of gender and age (age<60 years, n=36; age ≥ 60 years, n=38) on left ventricular systolic synchronicity were analyzed. The phase angle for original segmental contraction was measured to determine the onset of the ventricular contraction using 17-segment model. Forty healthy subjects were selected by simple random sampling method to evaluate the intra-observer and interobserver repeatability of QGS phase analysis software. Two-sample t test and linear correlation analysis were used to analyze the data. Results: The BW and SD of left ventricular in healthy subjects were (37.22 ±11.71)°, (11.84±5.39)° respectively. Comparisons between male and female for BW and SD yielded no statistical significance (BW: (36.00±9.70)°, (38.73±13.84)°; SD: (11.88±5.56)°, (11.79±5.26)°; t=0.96 and-0.07, both P>0.05); whereas the older subjects (age≥60 years) had larger BW than the others (age<60 years ; (39.95± 12.65)°, (34.33± 10.00)°; t=-2.11, P<0.05) and no statistical significance was shown for SD between the two age groups ((11.18±4.31)°, (12.54±6.33)°; t=1.08, P>0.05). Of the 74 subjects, the mechanical activation started from the ventricular base to apex in 54 subjects (73%), and from apex to base in only 20 subjects (27%). High repeatability of phase analysis was observed for both intra-observer and inter-observer (r=0.867-0.906, all P<0.001). Conclusions: Good left ventricular segmental synchrony is shown in healthy

  12. Echocardiographic assessment of the different left ventricular geometric patterns in hypertensive patients

    Directory of Open Access Journals (Sweden)

    Delma Maria Cunha

    2001-01-01

    Full Text Available OBJECTIVE: To identiy left ventricular geometric patterns in hypertensive patients on echocardiography, and to correlate those patterns with casual blood pressure measurements and with the parameters obtained on a 24-hour ambulatory blood pressure monitoring. METHODS: We studied sixty hypertensive patients, grouped according to the Joint National Committee stages of hypertension.. Using the single- and two-dimensional Doppler Echocardiography, we analyzed the left ventricular mass and the geometric patterns through the correlation of left ventricular mass index and relative wall thickness. On ambulatory blood pressure monitoring we assessed the means and pressure loads in the different geometric patterns detected on echocardiography RESULTS: We identified three left ventricular geometric patterns: 1 concentric hypertrophy, in 25% of the patients; 2 concentric remodeling, in 25%; and 3 normal geometry, in 50%. Casual systolic blood pressure was higher in the group with concentric hypertrophy than in the other groups (p=0.001. Mean systolic pressure in the 24h, daytime and nighttime periods was also higher in patients with concentric hypertrophy, as compared to the other groups (p=0.003, p=0.004 and p=0.007. Daytime systolic load and nighttime diastolic load were higher in patients with concentric hypertrophy ( p=0.004 and p=0.01, respectively. CONCLUSIONS: Left ventricular geometric patterns show significant correlation with casual systolic blood pressure, and with means and pressure loads on ambulatory blood pressure monitoring.

  13. Left Ventricular Electromechanical Mapping: A Case Study of Functional Assessment in Coronary Intervention

    OpenAIRE

    Perin, Emerson C.; Silva, Guilherme V.; Sarmento-Leite, Rogerio

    2000-01-01

    Electromechanical mapping is a new diagnostic tool that can be used to identify viable myocardium. In the case reported here, the technique was used before intervention to map areas of viable myocardium; post-intervention mapping showed improved mechanical function of the revascularized areas. Electromechanical mapping offers the potential of assessing left ventricular function in the cardiac catheterization laboratory before and after interventional procedures.

  14. [Assessment of the right ventricular anatomy and function by advanced echocardiography: pathological and physiological insights].

    Science.gov (United States)

    Lakatos, Bálint; Kovács, Attila; Tokodi, Márton; Doronina, Alexandra; Merkely, Béla

    2016-07-01

    Accurate assessment of right ventricular geometry and function is of high clinical importance. However, several limitations have to be taken into consideration if using conventional echocardiographic parameters. Advanced echocardiographic techniques, such as speckle-tracking analysis or 3D echocardiography are reliable and simple tools providing a cost-effective and non-invasive alternative of current modalities used to characterize the right ventricle. There is a growing interest in the diagnostic and prognostic value of these methods regarding pathological (right ventricular infarction, pulmonary hypertension, arrhythmogenic right ventricular dysplasia, follow-up of heart transplantation) and even physiological (athlete's heart) alterations of the right ventricle. Orv. Hetil., 2016, 157(29), 1139-1146.

  15. Limitation of myocardial infarct size and preservation of left ventricular function by early administration of APSAC in myocardial infarction.

    Science.gov (United States)

    Bassand, J P; Machecourt, J; Cassagnes, J; Lusson, J R; Borel, E; Schiele, F

    1989-07-05

    In cases of acute myocardial infarction (MI), it has been shown that preserving left ventricular function and limiting infarct size with early reperfusion of the occluded artery by means of a thrombolytic agent could eventually result in a reduced mortality rate. The aim of the APSIM study (anisoylated plasminogen streptokinase activator complex [APSAC] dans l'infarctus du Myocarde) was to demonstrate that early administration of APSAC in patients with recent acute MI could limit the infarct size and preserve left ventricular systolic function. In all, 231 patients with a first acute MI were randomly allocated to either APSAC (30 U over 5 minutes) or to conventional heparin therapy (5,000 IU in bolus injection) within 5 hours of the onset of symptoms. Of these patients, 112 received APSAC and 119 received heparin within a mean period of 188 +/- 62 minutes after the onset of symptoms. The patency rate of the infarct-related artery was 77% in the APSAC group and 36% in the heparin group (p less than 0.001). Left ventricular ejection fraction determined from contrast angiography was significantly higher in the APSAC than in the heparin group. This was true for the entire population (0.53 +/- 0.13 vs 0.47 +/- 0.13, p = 0.002) as well as for the subgroups of anterior and inferior wall infarctions (0.47 +/- 0.13 vs 0.4 +/- 0.16, p = 0.004 and 0.56 +/- 0.11 vs 0.51 +/- 0.09, p = 0.02). At 3 weeks, the difference remained significant for patients with anterior MI.(ABSTRACT TRUNCATED AT 250 WORDS)

  16. Size, shape, and stamina: the impact of left ventricular geometry on exercise capacity.

    Science.gov (United States)

    Lam, Carolyn S P; Grewal, Jasmine; Borlaug, Barry A; Ommen, Steve R; Kane, Garvan C; McCully, Robert B; Pellikka, Patricia A

    2010-05-01

    Although several studies have examined the cardiac functional determinants of exercise capacity, few have investigated the effects of structural remodeling. The current study evaluated the association between cardiac geometry and exercise capacity. Subjects with ejection fraction > or = 50% and no valvular disease, myocardial ischemia, or arrhythmias were identified from a large prospective exercise echocardiography database. Left ventricular mass index and relative wall thickness were used to classify geometry into normal, concentric remodeling, eccentric hypertrophy, and concentric hypertrophy. All of the subjects underwent symptom-limited treadmill exercise according to standard Bruce protocol. Maximal exercise tolerance was measured in metabolic equivalents. Of 366 (60+/-14 years; 57% male) subjects, 166 (45%) had normal geometry, 106 (29%) had concentric remodeling, 40 (11%) had eccentric hypertrophy, and 54 (15%) had concentric hypertrophy. Geometry was related to exercise capacity: in descending order, the maximum achieved metabolic equivalents were 9.9+/-2.8 in normal, 8.9+/-2.6 in concentric remodeling, 8.6+/-3.1 in eccentric hypertrophy, and 8.0+/-2.7 in concentric hypertrophy (all P<0.02 versus normal). Left ventricular mass index and relative wall thickness were negatively correlated with exercise tolerance in metabolic equivalents (r=-0.14; P=0.009 and r=-0.21; P<0.001, respectively). Augmentation of heart rate and ejection fraction with exercise were blunted in concentric hypertrophy compared with normal, even after adjusting for medications. In conclusion, the pattern of ventricular remodeling is related to exercise capacity among low-risk adults. Subjects with concentric hypertrophy display the greatest limitation, and this is related to reduced systolic and chronotropic reserve. Reverse remodeling strategies may prevent or treat functional decline in patients with structural heart disease.

  17. Left ventricular thrombus formation after acute myocardial infarction as assessed by cardiovascular magnetic resonance imaging

    International Nuclear Information System (INIS)

    Delewi, Ronak; Nijveldt, Robin; Hirsch, Alexander; Marcu, Constantin B.; Robbers, Lourens; Hassell, Marriela E.C.J.; Bruin, Rianne H.A. de; Vleugels, Jim; Laan, Anja M. van der; Bouma, Berto J.; Tio, René A.; Tijssen, Jan G.P.; Rossum, Albert C. van; Zijlstra, Felix; Piek, Jan J.

    2012-01-01

    Introduction: Left ventricular (LV) thrombus formation is a feared complication of myocardial infarction (MI). We assessed the prevalence of LV thrombus in ST-segment elevated MI patients treated with percutaneous coronary intervention (PCI) and compared the diagnostic accuracy of transthoracic echocardiography (TTE) to cardiovascular magnetic resonance imaging (CMR). Also, we evaluated the course of LV thrombi in the modern era of primary PCI. Methods: 200 patients with primary PCI underwent TTE and CMR, at baseline and at 4 months follow-up. Studies were analyzed by two blinded examiners. Patients were seen at 1, 4, 12, and 24 months for assessment of clinical status and adverse events. Results: On CMR at baseline, a thrombus was found in 17 of 194 (8.8%) patients. LV thrombus resolution occurred in 15 patients. Two patients had persistence of LV thrombus on follow-up CMR. On CMR at four months, a thrombus was found in an additional 12 patients. In multivariate analysis, thrombus formation on baseline CMR was independently associated with, baseline infarct size (g) (B = 0.02, SE = 0.02, p < 0.001). Routine TTE had a sensitivity of 21–24% and a specificity of 95–98% compared to CMR for the detection of LV thrombi. Intra- and interobserver variation for detection of LV thrombus were lower for CMR (κ = 0.91 and κ = 0.96) compared to TTE (κ = 0.74 and κ = 0.53). Conclusion: LV thrombus still occurs in a substantial amount of patients after PCI-treated MI, especially in larger infarct sizes. Routine TTE had a low sensitivity for the detection of LV thrombi and the interobserver variation of TTE was large.

  18. Left ventricular thrombus formation after acute myocardial infarction as assessed by cardiovascular magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Delewi, Ronak [Department of Cardiology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands); Interuniversity Cardiology Institute of the Netherlands (Netherlands); Nijveldt, Robin [Department of Cardiology, VU University Medical Center, Amsterdam (Netherlands); Hirsch, Alexander [Department of Cardiology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands); Marcu, Constantin B.; Robbers, Lourens [Department of Cardiology, VU University Medical Center, Amsterdam (Netherlands); Hassell, Marriela E.C.J.; Bruin, Rianne H.A. de; Vleugels, Jim; Laan, Anja M. van der; Bouma, Berto J. [Department of Cardiology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands); Tio, René A. [Thorax Center, University Medical Center Groningen, Groningen (Netherlands); Tijssen, Jan G.P. [Department of Cardiology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands); Rossum, Albert C. van [Department of Cardiology, VU University Medical Center, Amsterdam (Netherlands); Zijlstra, Felix [Thorax Center, Department of Cardiology, Erasmus University Medical Center, Rotterdam (Netherlands); Piek, Jan J., E-mail: j.j.piek@amc.uva.nl [Department of Cardiology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands)

    2012-12-15

    Introduction: Left ventricular (LV) thrombus formation is a feared complication of myocardial infarction (MI). We assessed the prevalence of LV thrombus in ST-segment elevated MI patients treated with percutaneous coronary intervention (PCI) and compared the diagnostic accuracy of transthoracic echocardiography (TTE) to cardiovascular magnetic resonance imaging (CMR). Also, we evaluated the course of LV thrombi in the modern era of primary PCI. Methods: 200 patients with primary PCI underwent TTE and CMR, at baseline and at 4 months follow-up. Studies were analyzed by two blinded examiners. Patients were seen at 1, 4, 12, and 24 months for assessment of clinical status and adverse events. Results: On CMR at baseline, a thrombus was found in 17 of 194 (8.8%) patients. LV thrombus resolution occurred in 15 patients. Two patients had persistence of LV thrombus on follow-up CMR. On CMR at four months, a thrombus was found in an additional 12 patients. In multivariate analysis, thrombus formation on baseline CMR was independently associated with, baseline infarct size (g) (B = 0.02, SE = 0.02, p < 0.001). Routine TTE had a sensitivity of 21–24% and a specificity of 95–98% compared to CMR for the detection of LV thrombi. Intra- and interobserver variation for detection of LV thrombus were lower for CMR (κ = 0.91 and κ = 0.96) compared to TTE (κ = 0.74 and κ = 0.53). Conclusion: LV thrombus still occurs in a substantial amount of patients after PCI-treated MI, especially in larger infarct sizes. Routine TTE had a low sensitivity for the detection of LV thrombi and the interobserver variation of TTE was large.

  19. Focused review on transthoracic echocardiographic assessment of patients with continuous axial left ventricular assist devices.

    Science.gov (United States)

    Topilsky, Yan; Maltais, Simon; Oh, Jae K; Atchison, Fawn W; Perrault, Louis P; Carrier, Michel; Park, Soon J

    2011-02-08

    Left ventricular assist devices (LVADs) are systems for mechanical support for patients with end-stage heart failure. Preoperative, postoperative and comprehensive followup with transthoracic echocardiography has a major role in LVAD patient management. In this paper, we will present briefly the hemodynamics of axial-flow LVAD, the rationale, and available data for a complete and organized echocardiographic assessment in these patients including preoperative assessment, postoperative and long-term evaluation.

  20. Assessment of cardiac performance with quantitative radionuclide angiocardiography: sequential left ventricular ejection fraction, normalized left ventricular ejection rate, and regional wall motion

    International Nuclear Information System (INIS)

    Marshall, R.C.; Berger, H.J.; Costin, J.C.; Freedman, G.S.; Wolberg, J.; Cohen, L.S.; Gotischalk, A.; Zaret, B.L.

    1977-01-01

    Sequential quantitative first pass radionuclide angiocardiograms (RA) were used to measure left ventricular ejection fraction (LVEF) and left ventricular ejection rate (LVER), and to assess regional wall motion (RWM) in the anterior (ANT) and left anterior oblique (LAO) positions. Studies were obtained with a computerized multicrystal scintillation camera suitable for acquiring high count-rate data. Background was determined in a new fashion by selecting frames temporally from the left ventricular region of interest time-activity curve. A ''representative'' cardiac cycle was formed by summing together counts over three to six cardiac cycles. From this background corrected, high count-rate ''representative''cardiac cycle, LVEF, LVER, and RWM were determined. In 22 patients with normal sinus rhythm in the absence of significant valvular regurgitation, RA LVEF correlated well with that measured by contrast angiography (r = 0.95). LVER correlated well with LVEF measured at contrast angiography (r = 0.90) and allowed complete separation of those with normal (LVER = 3.4 +- 0.17 sec -1 ) and abnormal (LVER = 1.22 +- 0.11 sec -1 ) (P < 0.001) left ventricular performance. This separation was independent of background. Isoproterenol infusion in five normal subjects caused LVER to increase by 81 +- 17% while LVEF increased by 10 +- 2.0%. RWM was correctly defined in 21/22 patients and 89% of left ventricular segments with abnormal wall motion

  1. Assessment of left ventricular function: comparison between radionuclide angiography and semiquantitative two-dimensional echocardiographic analysis

    International Nuclear Information System (INIS)

    Gottsauner-Wolf, M.; Schedlmayer-Duit, J.; Porenta, G.; Gwechenberger, M.; Huber, K.; Glogar, D.; Probst, P.; Sochor, H.

    1996-01-01

    Measurement of global left ventricular function is important in the follow-up of cardiac patients and is a good prognostic indicator in acute cardiac situations. We compared quantitative measurements of global left ventricular function made with radionuclide angiography (RNA) and contrast cardiac ventriculography (CVG) to visual semiquantitative estimates from two-dimensional echocardiographic images (2D-echo). Three hundred and thirty-nine consecutive patients who underwent RNA were assessed with 2D-echo within 3 months. In addition, 92 of these patients also underwent CVG (correlation of ejection fraction between CVG and RNA: r=0.82; P<0.0001). The RNA mean ejection fractions in the four 2D-echo groups (0=normal, 1=slightly, 2=moderate, or 3=severe reduced left ventricular function) differed markedly (P<0.0001); however, there was overlapping among the groups (2D-echo score/RNA ejection fraction: 0=57.3%±12.8%; 1=46.0%±12.9%; 2=29.6%± 12.2%; and 3=24.6%±11.5%) and the difference between 2D-echo scores 2 and 3 was not significant. 2D-echo showed a good concordance in RNA classes (0=≥505; 1=35%-49%; 2=21%-34%; and 3=≤20% ejection fraction) 0 (133/166; 80%) and 3 (18/30; 60%) but low concordance in classes 1 (27/82; 33%) and 2 (21/61; 34%). For accurate assessment of global left ventricular ejection fraction, visual semiquantitative judgement of a 2D echocardiographic image is limited in comparison to CVG or RNA, especially in patients with a slight or moderate reduction in left ventricular ejection fraction. (orig.). With 2 figs., 2 tabs

  2. Point-of-Care Ultrasonography to Assess Portal Vein Pulsatility and the Effect of Inhaled Milrinone and Epoprostenol in Severe Right Ventricular Failure: A Report of 2 Cases.

    Science.gov (United States)

    Tremblay, Jan-Alexis; Beaubien-Souligny, William; Elmi-Sarabi, Mahsa; Desjardins, Georges; Denault, André Y

    2017-10-15

    This article describes 2 patients with severe acute right ventricular failure causing circulatory shock. Portal vein pulsatility assessed by bedside ultrasonography suggested clinically relevant venous congestion. Management included cardiac preload reduction and combined inhalation of milrinone and epoprostenol to reduce right ventricular afterload. Portal vein ultrasonography may be useful in assessing right ventricular function in the acutely ill patient.

  3. Pressure-volume Relationship in the Stress-echocardiography Laboratory: Does (Left Ventricular End-diastolic) Size Matter?

    Science.gov (United States)

    Bombardini, Tonino; Mulieri, Louis A; Salvadori, Stefano; Costantino, Marco Fabio; Scali, Maria Chiara; Marzilli, Mario; Picano, Eugenio

    2017-02-01

    The variation between rest and peak stress end-systolic pressure-volume relation is an afterload-independent index of left ventricular contractility. Whether and to what extent it depends on end-diastolic volume remains unclear. The aim of this study was to assess the dependence of the delta rest-stress end-systolic pressure-volume relation on end-diastolic volume in patients with negative stress echo and all ranges of resting left ventricular function. We analyzed interpretable data obtained in 891 patients (593 men, age 63 ± 12 years) with ejection fraction 47% ± 12%: 338 were normal or near-normal or hypertensive; 229 patients had coronary artery disease; and 324 patients had ischemic or nonischemic dilated cardiomyopathy. They were studied with exercise (n = 172), dipyridamole (n = 482) or dobutamine (n = 237) stress echocardiography. The end-systolic pressure-volume relation was evaluated at rest and peak stress from raw measurement of systolic arterial pressure by cuff sphygmomanometer and end-systolic volume by biplane Simpson rule 2-dimensional echocardiography. Absolute values of delta rest-stress end-systolic pressure-volume relation were higher for exercise and dobutamine than for dipyridamole. In the overall population, an inverse relationship between end-systolic pressure-volume relation and end-diastolic volume was present at rest (r 2 = 0.69, P stress (r 2 = 0.56, P stress end-systolic pressure-volume relation was considered (r 2 = 0.13). Left ventricular end-diastolic volume does not affect the rest-stress changes in end-systolic pressure-volume relation in either normal or abnormal left ventricles during physical or pharmacological stress. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  4. Right and left ventricular ejection fraction at rest and during exercise assessed with radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Dahlstroem, J.A.

    1982-01-01

    Right (RVEF) and left ventricular ejection fraction (LVEF) assessed with radionuclide angiocardiography were compared to simultaneously obtained catheterization results at rest and during exercise in patients with pulmonary hypertension and ischemic heart disease. Blood pool imaging was performed with red blood cells (RBC) labelled with 99 Tcsup(m) in vivo as this method gave more stable 99 Tcsup(m) levels in blood compared to 99 Tcsup(m)-labelled human serum albumin and because it was more convenient than labelling RBC in vitro. RVEF measured with first pass (FP) technique and equilibrium (EQ) technique correlated well at rest, r = 0.86, and during exercise, r = 0.91. The FP technique had the best reproducibility and reference values at rest were 49+-5 per cent increasing with exercise. When 99 Tcsup(m) and 133 Xe were compared to assess RVEF with FP technique, the correlation was good, r = 0.88. LVEF assessed with EQ technique and a fixed end-diastolic region of interest was very reproducible at rest and during exercise; reference values at rest were 56+-8 per cent increasing with exercise. In 10 patients with pulmonary hypertension significant negative correlations were found between RVEF assessed with FP technique and pressures in pulmonary artery and right atrium. Abnormal RVEF was found in all patients with right ventricular disfunction. In 22 patients with recent myocardial infarction measurements of LVEF detected left ventricular disfunction better than did measurement of pulmonary artery diastolic pressure. During effort angina in another 10 patients all had abnormal LVEF and abnormal hemodynamics. By combining ejection fraction and stroke volume, ventricular volumes were calculated at rest and during exercise. (author)

  5. Effect of ventricular size and function on exercise performance and the electrocardiogram in repaired tetralogy of Fallot with pure pulmonary regurgitation

    International Nuclear Information System (INIS)

    Menon, Shaji C; Kaza, Aditya K; Puchalski, Michael D

    2012-01-01

    In repaired tetralogy of Fallot (TOF), exercise test parameters like peak oxygen uptake and ventilatory efficiency predict mortality. Studies have also suggested cardiac magnetic resonance (CMR)-derived right ventricular (RV) size threshold values for pulmonary valve replacement in repaired TOF. However, effects of proposed RV size on exercise capacity and morbidity are not known. The relationship between CMR-derived ventricular size, function, and pulmonary regurgitation (PR) and NYHA class, exercise performance, and electrocardiogram (ECG) was studied in patients of repaired TOF with pure PR in a retrospective review of records. 46 patients (22 females), mean age 14 years (8–30.8), were studied. There was no relationship between CMR-derived ventricular size, function, or PR and exercise test parameters, or NYHA class. RV end systolic and end diastolic volume correlated positively with the degree of PR. QRS duration on ECG correlated positively with RV end-diastolic volume (P < 0.01, r 2 = 0.34) and PR (P < 0.01, r 2 = 0.52). In repaired TOF and pure PR, there is no correlation between ventricular size or function and exercise performance. RV size increases with increasing PR. Timing of pulmonary valve replacement in TOF with pure PR needs further prospective evaluation for its effect on morbidity and mortality

  6. Optimal sizing for SAPIEN 3 transcatheter aortic valve replacement in patients with or without left ventricular outflow tract calcification.

    Science.gov (United States)

    Maeno, Yoshio; Abramowitz, Yigal; Jilaihawi, Hasan; Israr, Sharjeel; Yoon, Sunghan; Sharma, Rahul P; Kazuno, Yoshio; Kawamori, Hiroyuki; Miyasaka, Masaki; Rami, Tanya; Mangat, Geeteshwar; Takahashi, Nobuyuki; Okuyama, Kazuaki; Kashif, Mohammad; Chakravarty, Tarun; Nakamura, Mamoo; Cheng, Wen; Makkar, Raj R

    2017-04-07

    The impact of left ventricular outflow tract calcification (LVOT-CA) on SAPIEN 3 transcatheter aortic valve replacement (S3-TAVR) is not well understood. The aims of the present study were to determine optimal device sizing for S3-TAVR in patients with or without LVOT-CA and to evaluate the influence of residual paravalvular leak (PVL) on survival after S3-TAVR in these patients. This study analysed 280 patients (LVOT-CA=144, no LVOT-CA=136) undergoing S3-TAVR. Optimal annular area sizing was defined as % annular area sizing related to lower rates of ≥mild PVL. Annular area sizing was determined as follows: (prosthesis area/CT annulus area-1)×100. Overall, ≥mild PVL was present in 25.7%. Receiver operating characteristic curve analysis for prediction of ≥mild PVL in patients with LVOT-CA showed that 7.2% annular area sizing was identified as the optimal threshold (area under the curve [AUC] 0.71). Conversely, annular area sizing for no LVOT-CA appeared unrelated to PVL (AUC 0.58). Aortic annular injury was seen in four patients (average 15.5% annular area oversizing), three of whom had LVOT-CA. Although there was no difference in one-year survival between patients with ≥mild PVL and without PVL (log-rank p=0.91), subgroup analysis demonstrated that patients with ≥moderate LVOT-CA who had ≥mild PVL had lower survival compared to patients with ≥mild PVL and none or mild LVOT-CA (log-rank p=0.010). In the setting of LVOT-CA, an optimally sized S3 valve is required to reduce PVL and to increase survival following TAVR.

  7. Ventricular size and cortical atrophy in normal elderly volunteers and demented patients

    International Nuclear Information System (INIS)

    Chiba, Kazuo; Yamada, Hideo; Endoh, Kazuo

    1985-01-01

    Review of papers for methods of measuring sizes of ventricles and CSF space on CT revealed many different ways including subjective, linear, planimetric and volumetric methods. Results of these measurements were also reviewed and discussed together with our own study about normally acting elderly volunteers and patients with dimentia. The left lateral ventricle was significantly larger than the right. Sizes of ventricles and CSF spaces increased with aging. These differences were significant among five different age groups in female (younger than 60, sixties, seventies, eighties and older than 90). In male these differences were not significant among several age groups mainly because of a small number in an age group. There was no significant difference of sizes of ventricles and CSF space between male and female. The two variates analysis between sizes of ventricles and CSF space showed rightward shift of two main components in dementia compared with normal group. (author)

  8. Comparison of left ventricular function assessment between echocardiography and MRI in Duchenne muscular dystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Buddhe, Sujatha; Lewin, Mark; Olson, Aaron; Soriano, Brian D. [University of Washington School of Medicine and Seattle Children' s Hospital, Division of Cardiology, Department of Pediatrics, Seattle, WA (United States); Ferguson, Mark [University of Washington School of Medicine and Seattle Children' s Hospital, Department of Radiology, Seattle, WA (United States)

    2016-09-15

    Cardiomyopathy in Duchenne muscular dystrophy (DMD) is associated with death in approximately 40% of patients. Echocardiography is routinely used to assess left ventricular (LV) function; however, it has limitations in these patients. We compared echocardiographic measures of cardiac function assessment to cardiac MRI. We included children and young adults with DMD who had MRI performed between January 2010 and July 2015. We measured echocardiographic and MRI parameters of function assessment, including strain. Presence of late gadolinium enhancement (LGE) was assessed by MRI. Subjects were divided into two groups based on MRI left ventricular ejection fraction (LVEF): group I, LVEF ≥55% and group II, LVEF <55%. We included 41 studies in 33 subjects, with 25 in group I and 16 in group II. Mean age of subjects was 13.6 ± 2.8 years and mean duration between echocardiogram and MRI was 7.6 ± 4.1 months. Only 8 of 16 (50%) patients in group II had diminished function on echocardiogram. Echocardiographic images were suboptimal in 16 subjects (39%). Overall, echocardiographic parameters had weak correlation with MRI-derived ejection fraction percentage. MRI-derived myocardial strain assessment has better correlation with MRI ejection fraction as compared to echocardiography-derived strain parameters. Echocardiography-based ventricular functional assessment has weak correlation with MRI parameters in children and young adults with Duchenne muscular dystrophy. While this correlation improves in the subset of subjects with adequate echocardiographic image quality, it remains modest and potentially suboptimal for clinical management. Accordingly, we conclude that MRI should be performed routinely and early in children with DMD, not only for LGE imaging but also for functional assessment. (orig.)

  9. Comparison of left ventricular function assessment between echocardiography and MRI in Duchenne muscular dystrophy

    International Nuclear Information System (INIS)

    Buddhe, Sujatha; Lewin, Mark; Olson, Aaron; Soriano, Brian D.; Ferguson, Mark

    2016-01-01

    Cardiomyopathy in Duchenne muscular dystrophy (DMD) is associated with death in approximately 40% of patients. Echocardiography is routinely used to assess left ventricular (LV) function; however, it has limitations in these patients. We compared echocardiographic measures of cardiac function assessment to cardiac MRI. We included children and young adults with DMD who had MRI performed between January 2010 and July 2015. We measured echocardiographic and MRI parameters of function assessment, including strain. Presence of late gadolinium enhancement (LGE) was assessed by MRI. Subjects were divided into two groups based on MRI left ventricular ejection fraction (LVEF): group I, LVEF ≥55% and group II, LVEF <55%. We included 41 studies in 33 subjects, with 25 in group I and 16 in group II. Mean age of subjects was 13.6 ± 2.8 years and mean duration between echocardiogram and MRI was 7.6 ± 4.1 months. Only 8 of 16 (50%) patients in group II had diminished function on echocardiogram. Echocardiographic images were suboptimal in 16 subjects (39%). Overall, echocardiographic parameters had weak correlation with MRI-derived ejection fraction percentage. MRI-derived myocardial strain assessment has better correlation with MRI ejection fraction as compared to echocardiography-derived strain parameters. Echocardiography-based ventricular functional assessment has weak correlation with MRI parameters in children and young adults with Duchenne muscular dystrophy. While this correlation improves in the subset of subjects with adequate echocardiographic image quality, it remains modest and potentially suboptimal for clinical management. Accordingly, we conclude that MRI should be performed routinely and early in children with DMD, not only for LGE imaging but also for functional assessment. (orig.)

  10. [Implantable sensors for outpatient assessment of ventricular filling pressure in advanced heart failure : Which telemonitoring design is optimal?

    Science.gov (United States)

    Herrmann, E; Fichtlscherer, S; Hohnloser, S H; Zeiher, A M; Aßmus, B

    2016-12-01

    Patients with advanced heart failure suffer from frequent hospitalizations. Non-invasive hemodynamic telemonitoring for assessment of ventricular filling pressure has been shown to reduce hospitalizations. We report on the right ventricular (RVP), the pulmonary artery (PAP) and the left atrial pressure (LAP) sensor for non-invasive assessment of the ventricular filling pressure. A literature search concerning the available implantable pressure sensors for noninvasive haemodynamic telemonitoring in patients with advanced heart failure was performed. Until now, only implantation of the PAP-sensor was able to reduce hospitalizations for cardiac decompensation and to improve quality of life. The right ventricular pressure sensor missed the primary endpoint of a significant reduction of hospitalizations, clinical data using the left atrial pressure sensor are still pending. The implantation of a pressure sensor for assessment of pulmonary artery filling pressure is suitable for reducing hospitalizations for heart failure and for improving quality of life in patients with advanced heart failure.

  11. Impact of aortic root size on left ventricular afterload and stroke volume.

    Science.gov (United States)

    Sahlén, Anders; Hamid, Nadira; Amanullah, Mohammed Rizwan; Fam, Jiang Ming; Yeo, Khung Keong; Lau, Yee How; Lam, Carolyn S P; Ding, Zee Pin

    2016-07-01

    The left ventricle (LV) ejects blood into the proximal aorta. Age and hypertension are associated with stiffening and dilation of the aortic root, typically viewed as indicative of adverse remodeling. Based on analytical considerations, we hypothesized that a larger aortic root should be associated with lower global afterload (effective arterial elastance, EA) and larger stroke volume (SV). Moreover, as antihypertensive drugs differ in their effect on central blood pressure, we examined the role of antihypertensive drugs for the relation between aortic root size and afterload. We studied a large group of patients (n = 1250; 61 ± 12 years; 78 % males; 64 % hypertensives) from a single-center registry with known or suspected coronary artery disease. Aortic root size was measured by echocardiography as the diameter of the tubular portion of the ascending aorta. LV outflow tract Doppler was used to record SV. In the population as a whole, after adjusting for key covariates in separate regression models, aortic root size was an independent determinant of both SV and EA. This association was found to be heterogeneous and stronger in patients taking a calcium channel blocker (CCB; 10.6 % of entire population; aortic root size accounted for 8 % of the explained variance of EA). Larger aortic root size is an independent determinant of EA and SV. This association was heterogeneous and stronger in patients on CCB therapy.

  12. Dynamic changes in left ventricular function during cold pressor stimulation assessed with gold-195m

    International Nuclear Information System (INIS)

    Dymond, D.S.; Caplin, J.; Flatman, W.

    1985-01-01

    The temporal changes in left ventricular function induced by cold pressor stimulation were assessed in 12 normal controls and 12 patients with coronary artery disease (CAD) by rapid, sequential first-pass nuclear angiography with gold-195m. Imaging was performed at rest, after 1, 2.5, and 4 min of cold pressor and after 2 min of recovery. After 1 min, LVEF (left ventricular ejection fraction) fell significantly in normals and in patients but only in the coronary patients was a significant fall maintained at 2.5 and 4 min. The number of new abnormalities on the regional ejection fraction images for normals and those with CAD, respectively, was 12 and 19 at 1 min, 1 and 21 at 2.5 min, 2 and 13 at 4 min, and 0 and 8 during recovery. The authors conclude that (1) cold pressor-induced depression of left ventricular function is transient in normals but often prolonged in patients with CAD and (2) the temporal dissociation between rise in blood pressure and fall in LVEF suggests factors other than afterload changes may be involved in depression of cardiac function

  13. Serial assessment of left ventricular function following coronary bypass surgery by radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Kawasuji, Michio; Sawa, Shigeharu; Sakakibara, Naoki; Iwa, Takashi; Taki, Junichi; Bunko, Hisashi

    1988-01-01

    The serial change in left ventricular function was investigated by radionuclide angiocardiography in 25 patients undergoing coronary artery bypass grafting (CABG). Multiple gated equilibrium blood pool imaging was performed at rest before, and at 1, 2 and 4 weeks after the operation and also during exercise on a supine bicycle ergometer before and 4 weeks after surgery. Global ejection fraction at rest was unchanged after CABG while peak ejection rate increased significantly at 1 and 2 weeks (p < 0.01 and p < 0.05 respectively) after the operation. Peak filling rate at rest was generally unchanged after surgery but peak filling rate during the first third of diastole at rest decreased significantly at 1 and 2 weeks (p < 0.01 and p < 0.05). After CABG, the increases in ejection fraction and peak ejection rate with exercise were significantly greater than those values measured before surgery. The increases, due to exercise, in peak filling rate and peak filling rate during the first third of diastole were unchanged after the operation. Radionuclide angiocardiography affords a safe, noninvasive, and highly reproducible procedure for serially assessing ventricular function in patients undergoing CABG. Our study revealed early diastolic dysfunction within 2 weeks of surgery and that CABG abolished abnormalities in left ventricular function induced by exercise. (author)

  14. Ventricular dyssynchrony assessed by gated myocardial perfusion SPECT using a geometrical approach: a feasibility study

    International Nuclear Information System (INIS)

    Veen, Berlinda J. van der; Younis, Imad Al; Ajmone-Marsan, Nina; Bax, Jeroen J.; Westenberg, Jos J.M.; Roos, Albert de; Stokkel, Marcel P.M.

    2012-01-01

    Left ventricular dyssynchrony may predict response to cardiac resynchronization therapy and may well predict adverse cardiac events. Recently, a geometrical approach for dyssynchrony analysis of myocardial perfusion scintigraphy (MPS) was introduced. In this study the feasibility of this geometrical method to detect dyssynchrony was assessed in a population with a normal MPS and in patients with documented ventricular dyssynchrony. For the normal population 80 patients (40 men and 40 women) with normal perfusion (summed stress score ≤2 and summed rest score ≤2) and function (left ventricular ejection fraction 55-80%) on MPS were selected; 24 heart failure patients with proven dyssynchrony on MRI were selected for comparison. All patients underwent a 2-day stress/rest MPS protocol. Perfusion, function and dyssynchrony parameters were obtained by the Corridor4DM software package (Version 6.1). For the normal population time to peak motion was 42.8 ± 5.1% RR cycle, SD of time to peak motion was 3.5 ± 1.4% RR cycle and bandwidth was 18.2 ± 6.0% RR cycle. No significant gender-related differences or differences between rest and post-stress acquisition were found for the dyssynchrony parameters. Discrepancies between the normal and abnormal populations were most profound for the mean wall motion (p value <0.001), SD of time to peak motion (p value <0.001) and bandwidth (p value <0.001). It is feasible to quantify ventricular dyssynchrony in MPS using the geometrical approach as implemented by Corridor4DM. (orig.)

  15. 2D-speckle tracking right ventricular strain to assess right ventricular systolic function in systolic heart failure. Analysis of the right ventricular free and posterolateral walls.

    Science.gov (United States)

    Mouton, Stéphanie; Ridon, Héléne; Fertin, Marie; Pentiah, Anju Duva; Goémine, Céline; Petyt, Grégory; Lamblin, Nicolas; Coisne, Augustin; Foucher-Hossein, Claude; Montaigne, David; de Groote, Pascal

    2017-10-15

    Right ventricular (RV) systolic function is a powerful prognostic factor in patients with systolic heart failure. The accurate estimation of RV function remains difficult. The aim of the study was to determine the diagnostic accuracy of 2D-speckle tracking RV strain in patients with systolic heart failure, analyzing both free and posterolateral walls. Seventy-six patients with dilated cardiopathy (left ventricular end-diastolic volume≥75ml/m 2 ) and left ventricular ejection fraction≤45% had an analysis of the RV strain. Feasibility, reproducibility and diagnostic accuracy of RV strain were analyzed and compared to other echocardiographic parameters of RV function. RV dysfunction was defined as a RV ejection fraction≤40% measured by radionuclide angiography. RV strain feasibility was 93.9% for the free-wall and 79.8% for the posterolateral wall. RV strain reproducibility was good (intra-observer and inter-observer bias and limits of agreement of 0.16±1.2% [-2.2-2.5] and 0.84±2.4 [-5.5-3.8], respectively). Patients with left heart failure have a RV systolic dysfunction that can be unmasked by advanced echocardiographic imaging: mean RV strain was -21±5.7% in patients without RV dysfunction and -15.8±5.1% in patients with RV dysfunction (p=0.0001). Mean RV strain showed the highest diagnostic accuracy to predict depressed RVEF (area under the curve (AUC) 0.75) with moderate sensitivity (60.5%) but high specificity (87.5%) using a cutoff value of -16%. RV strain seems to be a promising and more efficient measure than previous RV echocardiographic parameters for the diagnosis of RV systolic dysfunction. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Assessment of right ventricular function with nonimaging first pass ventriculography and comparison of results with gamma camera studies.

    Science.gov (United States)

    Zhang, Z; Liu, X J; Liu, Y Z; Lu, P; Crawley, J C; Lahiri, A

    1990-08-01

    A new technique has been developed for measuring right ventricular function by nonimaging first pass ventriculography. The right ventricular ejection fraction (RVEF) obtained by non-imaging first pass ventriculography was compared with that obtained by gamma camera first pass and equilibrium ventriculography. The data has demonstrated that the correlation of RVEFs obtained by the nonimaging nuclear cardiac probe and by gamma camera first pass ventriculography in 15 subjects was comparable (r = 0.93). There was also a good correlation between RVEFs obtained by the nonimaging nuclear probe and by equilibrium gated blood pool studies in 33 subjects (r = 0.89). RVEF was significantly reduced in 15 patients with right ventricular and/or inferior myocardial infarction compared to normal subjects (28 +/- 9% v. 45 +/- 9%). The data suggests that nonimaging probes may be used for assessing right ventricular function accurately.

  17. [Assessment of left ventricular twist in type 2 diabetes mellitus by using two-dimensional ultrasound speckle tracking imaging].

    Science.gov (United States)

    Zhu, Pei-hua; Huang, Jing-yuan; Ye, Meng; Zheng, Zhe-lan

    2014-09-01

    To evaluate the left ventricular twist characteristics in patients with type 2 diabetes by using two-dimensional speckle tracking imaging (STI). Ninety-three patients with type 2 diabetes admitted in Zhejiang Hospital from May 2012 to September 2013 were enrolled. According to left ventricular ejection fraction (LVEF), patients were divided into two groups: normal left ventricular systolic function group (group A, LVEF≥0.50, n=46) and abnormal left ventricular systolic function group (group B, LVEF Consistency check for STI was conducted to assess its stability and reliability. The Peaktw, AVCtw, and MVOtw in group A were significantly elevated than those in normal controls (Pconsistency limit=-2.8-2.7; within measurer: R=0.964, bias=-0.2, 95% consistency limits=-2.7-2.2). STI can be used for early recognition of abnormal changes of cardiac function in type 2 diabetic mellitus patients, with high stability and reliability.

  18. Assessment of the right ventricular function in patients with chronic obstructive pulmonary disease using MRI

    International Nuclear Information System (INIS)

    Gao Yan; Du Xiangying; Qin Wen; Li Kuncheng

    2011-01-01

    Background: Chronic obstructive pulmonary disease (COPD) is often associated with changes of the structure and the function of the right ventricle (RV). Therefore, the assessment of right ventricular function and myocardial mass (MM) is clinically important for the evaluation of the severity of COPD, which may provide an objective basis for therapeutic strategy. Purpose: To assess the right ventricular function and RV MM in patients with mild to severe COPD using magnetic resonance imaging (MRI). Material and Methods: We prospectively studied 49 COPD patients determined by the pulmonary function test (PFT). Using the Global Initiative for COPD classification, the COPD patients were divided into three groups according to the severity of the disease: group I = mild (n = 18); group II = moderate (n = 16); and group III = severe (n = 15). The patient groups were compared to a control group consisting of 30 age-matched, healthy, non-smoking subjects. The RV function and RV MM were obtained by 1.5T cardiac MRI in all of the four groups. The results were compared among the four groups using the ANOVA. Pearson's correlation was used to evaluate the relationship between the right ventricular ejection fraction (RVEF) and MM with the PFT results in COPD patients. Results: The RVEF was significantly lower in group III than in the other groups (P < 0.01). The RV MM differed significantly among all groups (P < 0.01) and gradually increased with the severity of COPD (P < 0.01). The correlation was significant between the MRI results and forced expiratory volume in 1 s (r = 0.860 for RVEF, r = -0.838 for RV MM) in COPD patients. Conclusion: The RVEF and RV MM measured by MRI correlate significantly with the severity of disease as determined by PFT in patients with COPD

  19. Assessment of the right ventricular function in patients with chronic obstructive pulmonary disease using MRI

    Energy Technology Data Exchange (ETDEWEB)

    Gao Yan; Du Xiangying; Qin Wen; Li Kuncheng (Dept. of Radiology, Xuanwu Hospital of Capital Medical Univ., Beijing (China)), email: kuncheng.li@gmail.com

    2011-09-15

    Background: Chronic obstructive pulmonary disease (COPD) is often associated with changes of the structure and the function of the right ventricle (RV). Therefore, the assessment of right ventricular function and myocardial mass (MM) is clinically important for the evaluation of the severity of COPD, which may provide an objective basis for therapeutic strategy. Purpose: To assess the right ventricular function and RV MM in patients with mild to severe COPD using magnetic resonance imaging (MRI). Material and Methods: We prospectively studied 49 COPD patients determined by the pulmonary function test (PFT). Using the Global Initiative for COPD classification, the COPD patients were divided into three groups according to the severity of the disease: group I = mild (n = 18); group II = moderate (n = 16); and group III = severe (n = 15). The patient groups were compared to a control group consisting of 30 age-matched, healthy, non-smoking subjects. The RV function and RV MM were obtained by 1.5T cardiac MRI in all of the four groups. The results were compared among the four groups using the ANOVA. Pearson's correlation was used to evaluate the relationship between the right ventricular ejection fraction (RVEF) and MM with the PFT results in COPD patients. Results: The RVEF was significantly lower in group III than in the other groups (P < 0.01). The RV MM differed significantly among all groups (P < 0.01) and gradually increased with the severity of COPD (P < 0.01). The correlation was significant between the MRI results and forced expiratory volume in 1 s (r = 0.860 for RVEF, r = -0.838 for RV MM) in COPD patients. Conclusion: The RVEF and RV MM measured by MRI correlate significantly with the severity of disease as determined by PFT in patients with COPD

  20. Variability of left ventricular ejection fraction and volumes with quantitative gated SPECT: influence of algorithm, pixel size and reconstruction parameters in small and normal-sized hearts

    International Nuclear Information System (INIS)

    Hambye, Anne-Sophie; Vervaet, Ann; Dobbeleir, Andre

    2004-01-01

    Several software packages are commercially available for quantification of left ventricular ejection fraction (LVEF) and volumes from myocardial gated single-photon emission computed tomography (SPECT), all of which display a high reproducibility. However, their accuracy has been questioned in patients with a small heart. This study aimed to evaluate the performances of different software and the influence of modifications in acquisition or reconstruction parameters on LVEF and volume measurements, depending on the heart size. In 31 patients referred for gated SPECT, 64 2 and 128 2 matrix acquisitions were consecutively obtained. After reconstruction by filtered back-projection (Butterworth, 0.4, 0.5 or 0.6 cycles/cm cut-off, order 6), LVEF and volumes were computed with different software [three versions of Quantitative Gated SPECT (QGS), the Emory Cardiac Toolbox (ECT) and the Stanford University (SU-Segami) Medical School algorithm] and processing workstations. Depending upon their end-systolic volume (ESV), patients were classified into two groups: group I (ESV>30 ml, n=14) and group II (ESV 2 to 128 2 were associated with significantly larger volumes as well as lower LVEF values. Increasing the filter cut-off frequency had the same effect. With SU-Segami, a larger matrix was associated with larger end-diastolic volumes and smaller ESVs, resulting in a highly significant increase in LVEF. Increasing the filter sharpness, on the other hand, had no influence on LVEF though the measured volumes were significantly larger. (orig.)

  1. Echocardiographic assessment of right ventricular contractile reserve in patients with pulmonary hypertension.

    Science.gov (United States)

    Almeida, Ana Rita; Loureiro, Maria José; Lopes, Liliana; Cotrim, Carlos; Lopes, Luís; Repolho, Débora; Pereira, Hélder

    2014-03-01

    Right ventricular function is a major determinant of prognosis in pulmonary hypertension. The aim of this study was to assess and compare right ventricular contractile reserve in healthy subjects (controls) and in subjects with pulmonary hypertension (cases). In this prospective study of seven cases and seven controls undergoing treadmill stress echocardiography, right ventricular S-wave velocity, tricuspid annular plane systolic excursion (TAPSE), right ventricular fractional area change (RVFAC) and stroke volume index were assessed at rest and with exercise. The increase in each parameter between rest and exercise for cases and controls was analyzed and the magnitude of change in each parameter with exercise between cases and controls was compared. A significant increase in S-wave velocity was observed in cases (rest: 9.4 ± 3.1; exercise: 13.7 ± 4.8 cm/s [p < 0.05]). In controls there was a statistically significant increase in S-wave velocity (12.9 ± 2.3 to 23.0 ± 7.2 cm/s [p < 0.005]), TAPSE (25.7 ± 2.4 to 31.0 ± 3.5 mm [p < 0.05]) and RVFAC (53.8 ± 14.7% to 64.4 ± 9.9% [p < 0.005]). The magnitude of change in S-wave velocity (cases: 4.3 ± 3.3; controls: 10.1 ± 5.5 cm/s [p < 0.05]), TAPSE (cases: 0.6 ± 2.5; controls: 5.3 ± 3.8 mm [p < 0.05]) and RVFAC (cases: -0.4 ± 11.8; controls: 10.6 ± 5.9% [p < 0.05]) was significantly different between cases and controls. S-wave velocity, TAPSE and RVFAC increased significantly with exercise in controls. S-wave velocity was the only parameter that showed a significant increase in cases, although the magnitude of this increase was significantly less than in controls. Copyright © 2013 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  2. Clinical assessment of the effect of digital filtering on the detection of ventricular late potentials

    Directory of Open Access Journals (Sweden)

    P.R. Benchimol-Barbosa

    2002-11-01

    Full Text Available Ventricular late potentials are low-amplitude signals originating from damaged myocardium and detected on the body surface by ECG filtering and averaging. Digital filters present in commercial equipment may interfere with the ability of arrhythmia stratification. We compared 40-Hz BiSpec (BI and classical 40- to 250-Hz band-pass Butterworth bidirectional (BD filters in terms of impact on time domain variables and diagnostic properties. In a transverse retrospective age-adjusted case-control study, 221 subjects with sinus rhythm without bundle branch block were divided into three groups after signal-averaged ECG acquisition: GI (N = 40, clinically normal controls, GII (N = 158, subjects with coronary heart disease without sustained monomorphic ventricular tachycardia (SMVT, and GIII (N = 23, subjects with heart disease and documented SMVT. Conventional variables analyzed from vector magnitude data after averaging to 0.3 µV final noise were obtained by application of each filter to the averaged signal, and evaluated in pairs by numerical comparison and by diagnostic agreement assessment, using conventional and optimized thresholds of normality. Significant differences were found between BI and BD variables in all groups, with diagnostic results showing significant disagreement between both filters [kappa value of 0.61 (P<0.05 for GII and 0.31 for GIII (P = NS]. Sensitivity for SMVT was lower with BI than with BD (65.2 vs 91.3%, respectively, P<0.05. Filters provided significantly different numerical and diagnostic results and the BI filter showed only limited clinical application to risk stratification of ventricular arrhythmia.

  3. EVALUACIÓN ECOCARDIOGRÁFICA DE LA FUNCIÓN VENTRICULAR IZQUIERDA EN CENTENARIOS / Echocardiographic assessment of left ventricular function in centenarians

    Directory of Open Access Journals (Sweden)

    Vanessa Peña-Bofill

    2013-10-01

    General Calixto García University Hospital, to whom echocardiography was performed to assess left ventricular function. Results: The mean age was 102 years old, females were predominant with 15 patients (75% and 50% had white skin color. The most prevalent coronary risk factor was hypertension (40%; diabetes mellitus type 2, dyslipidemia, and smoking followed in this order. Centenarians had preserved systolic function of the left ventricle (90% with little tendency to supernormality, one patient had segmental contractility disorders in the underside, which corresponded to a history of myocardial infarction. Four centenarians had normal filling pattern, 11 had impaired ventricular relaxation and five pseudonormal patterns. Conclusions: In the centenarians studied, the left ventricular systolic function as assessed by echocardiography is maintained within normal parameters, with signs of mild diastolic dysfunction.

  4. Beat-to-beat assessment of left ventricular ejection in atrial fibrillation

    Energy Technology Data Exchange (ETDEWEB)

    Benjelloun, H; Brochier, M; Itti, R; Philippe, L; Lorgeron, J M

    1983-05-01

    Beat-to-beat left ventricular ejection was evaluated in a group of 20 patients with chronic atrial fibrillation using a computerized single probe detector. The reference group consisted of 10 patients with sinus rhythm. For each patient 30 successive cardiac cycles were analyzed and the relative variations of four parameters were assessed: R-R interval, diastolic and systolic time intervals, and ejection amplitude, corresponding to the left ventricular stroke volume. The mean variations were respectively 3.4%, 10.4%, 8.4%, and 11.8% in patients with sinus rhythm, and 21.9%, 37.9%, 10.6% and 30.5% in patients with artrial fibrillation. This demonstrates that changes in ejection are mainly related to the duration of the filling phase, with nearly constant systolic times. Correlations between R-R intervals and systolic ejection amplitudes were highly significant (P<0.001) in patients with atrial fibrillation in 85% of cases. This information complements the average ejection fraction obtained from multiple cycle superimposition.

  5. Beat-to-beat assessment of left ventricular ejection in atrial fibrillation

    International Nuclear Information System (INIS)

    Benjelloun, H.; Brochier, M.; Itti, R.; Philippe, L.; Lorgeron, J.M.

    1983-01-01

    Beat-to-beat left ventricular ejection was evaluated in a group of 20 patients with chronic atrial fibrillation using a computerized single probe detector. The reference group consisted of 10 patients with sinus rhythm. For each patient 30 successive cardiac cycles were analyzed and the relative variations of four parameters were assessed: R-R interval, diastolic and systolic time intervals, and ejection amplitude, corresponding to the left ventricular stroke volume. The mean variations were respectively 3.4%, 10.4%, 8.4%, and 11.8% in patients with sinus rhythm, and 21.9%, 37.9%, 10.6% and 30.5% in patients with artrial fibrillation. This demonstrates that changes in ejection are mainly related to the duration of the filling phase, with nearly constant systolic times. Correlations between R-R intervals and systolic ejection amplitudes were highly significant (P<0.001) in patients with atrial fibrillation in 85% of cases. This information complements the average ejection fraction obtained from multiple cycle superimposition. (orig.)

  6. Internal medicine point-of-care ultrasound assessment of left ventricular function correlates with formal echocardiography.

    Science.gov (United States)

    Johnson, Benjamin K; Tierney, David M; Rosborough, Terry K; Harris, Kevin M; Newell, Marc C

    2016-02-01

    Although focused cardiac ultrasonographic (FoCUS) examination has been evaluated in emergency departments and intensive care units with good correlation to formal echocardiography, accuracy for the assessment of left ventricular systolic function (LVSF) when performed by internal medicine physicians still needs independent evaluation. This prospective observational study in a 640-bed, academic, quaternary care center, included 178 inpatients examined by 10 internal medicine physicians who had completed our internal medicine bedside ultrasound training program. The ability to estimate LVSF with FoCUS as "normal," "mild to moderately decreased," or "severely decreased" was compared with left ventricular ejection fraction (>50%, 31-49%, and internal medicine physician-performed FoCUS and formal echocardiography for any LVSF impairment was "good/substantial" with κ = 0.77 (p Internal medicine physicians using FoCUS identify normal versus decreased LVSF with high sensitivity, specificity, and "good/substantial" interrater agreement when compared with formal echocardiography. These results support the role of cardiac FoCUS by properly trained internal medicine physicians for discriminating normal from reduced LVSF. © 2015 Wiley Periodicals, Inc.

  7. Assessment of left ventricular hemodynamics by Gd-DTPA enhanced high speed cine MRI

    International Nuclear Information System (INIS)

    Matsumura, Kentaro; Nakase, Emiko; Kawai, Ichiro

    1992-01-01

    To assess the validity of Gd-DTPA enhanced high speed cine MRI in left ventricular (LV) volumes and ejection fraction (EF), high speed cine MRI was compared with intra-venous digital subtraction left ventriculography (IV-DSA) in 14 patients. All patients underwent conventional cine MRI and Gd-DTPA enhanced high speed MRI, simultaneously. The pulse sequences of high speed MRI were TR 8 ms (TR 6 ms plus rewind pulse 2 ms), TE 3.2 ms, matrix 128, phase encode 8 or 6 and NEX 1. Comparison with LV-volume showed a high correlation (y = 0.854x + 1,699, r = 0.985) between high speed cine MRI and VI-DSA. To make left ventricular volume curve by area-length method in cine MRI, manual tracing of LV-cavity was more difficult in conventional cine MRI-method than enhanced high speed cine MRI-method. In conclusion, first pass-Gd-DTPA enhanced high speed cine MRI, using the horizontal long axis approach and the multiphase study, is a highly, accurate reproducible method of evaluating LV-volumetry. (author)

  8. Right ventricular function assessed by 2D strain analysis predicts ventricular arrhythmias and sudden cardiac death in patients after acute myocardial infarction

    DEFF Research Database (Denmark)

    Risum, Niels; Valeur, Nana; Søgaard, Peter

    2017-01-01

    Aims: Left ventricular function is a well-established predictor of malignant ventricular arrhythmias, but little is known about the importance of right ventricular (RV) function. The aim of this study was to investigate the importance of RV function for prediction of sudden cardiac death (SCD) or...

  9. Assessment of left ventricular function and volumes by myocardial perfusion scintigraphy - comparison of two algorithms

    International Nuclear Information System (INIS)

    Zajic, T.; Fischer, R.; Brink, I.; Moser, E.; Krause, T.; Saurbier, B.

    2001-01-01

    Aim: Left ventricular volume and function can be computed from gated SPECT myocardial perfusion imaging using emory cardiac toolbox (ECT) or gated SPECT quantification (GS-Quant). The aim of this study was to compare both programs with respect to their practical application, stability and precision on heart-models as well as in clinical use. Methods: The volumes of five cardiac models were calculated by ECT and GS-Quant. 48 patients (13 female, 35 male) underwent a one day stress-rest protocol and gated SPECT. From these 96 gated SPECT images, left ventricular ejection fraction (LVEF), end-diastolic volume (EDV) and end-systolic volume (ESV) were estimated by ECT and GS-Quant. For 42 patients LVEF was also determined by echocardiography. Results: For the cardiac models the computed volumes showed high correlation with the model-volumes as well as high correlation between ECT and GS-Quant (r ≥0.99). Both programs underestimated the volume by approximately 20-30% independent of the ventricle-size. Calculating LVEF, EDV and ESV, GS-Quant and ECT correlated well to each other and to the LVEF estimated by echocardiography (r ≥0.86). LVEF values determined with ECT were about 10% higher than values determined with GS-Quant or echocardiography. The incorrect surfaces calculated by the automatic algorithm of GS-Quant for three examinations could not be corrected manually. 34 of the ECT studies were optimized by the operator. Conclusion: GS-Quant and ECT are two reliable programs in estimating LVEF. Both seem to underestimate the cardiac volume. In practical application GS-Quant was faster and easier to use. ECT allows the user to define the contour of the ventricle and thus is less susceptible to artifacts. (orig.) [de

  10. Influence of Maternal Undernutrition and Overfeeding on Cardiac Ciliary Neurotrophic Factor Receptor and Ventricular Size in Fetal Sheep

    Science.gov (United States)

    Dong, Feng; Ford, Stephen P.; Nijland, Mark J.; Nathanielsz, Peter W.; Ren, Jun

    2008-01-01

    Intrauterine nutrition status is reported to correlate with risk of cardiovascular diseases in adulthood. Either under- or over-nutrition during early to mid gestation contributes to altered fetal growth and ventricular geometry. This study was designed to examine myocardial expression of ciliary neurotrophic factor receptor α (CTNFRα) and its down-stream mediator signal transducer and activator of transcription 3 (STAT3) on maternal under- or over-nutrition-induced changes in fetal heart weight. Multiparous ewes were fed with 50% (nutrient-restricted, NR), 100% (control) or 150% (overfed, OF) of NRC requirements from 28 to 78 days of gestation (dG; Term 148 dG). Ewes were euthanized on day 78, and the gravid uteri and fetuses recovered. Ventricular protein expression of CTNFRα, STAT3, phosphorylated STAT3, insulin-like growth factor I receptor (IGF-1R) and IGF binding protein 3 (IGFBP3) were quantitated using western blot. Plasma cortisol levels were higher in both NR and OF fetuses whereas plasma IGF-1 levels were lower and higher, in NR and OF fetuses. Fetal weights were reduced by 29.9% in NR ewes and were increased by 22.2% in fetuses from OF ewes compared to control group. Nutrient restriction did not affect fetal heart or ventricular weights whereas overfeeding increased heart and ventricular weights. Protein expression of CTNFRα in fetal ventricular tissue was reduced in OF group whereas STAT3 and pSTAT3 levels were reduced in both NR and OF groups. Expression of IGF-1R and IGFBP3 was unaffected in either NR or OF group. These data suggested that compared with maternal undernutrition, intrauterine overfeeding during early to mid gestation is associated with increases fetal blood concentrations of cortisol and IGF-1 in association with ventricular hypertrophy where reduced expression of CNTFRα and STAT3 may play a role. PMID:17869083

  11. Assessment of right ventricular function by myocardial performance index in diabetic patients

    Directory of Open Access Journals (Sweden)

    Ayman Ahmed Abdelaziz

    2011-09-01

    Conclusion: Myocardial performance index is a useful noninvasive tool for the detection of early right ventricular systolic and diastolic dysfunction in diabetic patients, regardless of coexisting hypertension.

  12. The repeatability of left ventricular volume assessment by a new ambulatory radionuclide monitoring system during head-up tilt

    International Nuclear Information System (INIS)

    Takase, Bonpei; Hosaka, Haruhiko; Kitamura, Katsuhiro

    2001-01-01

    The precise measurement of changes in left ventricular volume is important to elucidate the mechanisms of neurally mediated syncope. This study was conducted to determine whether or not a brand-new ambulatory radionuclide monitoring system (C-VEST system) can be clinically used to easily and precisely measure left ventricular volume and function in tilt testing. To assess the repeatability of the C-VEST system, 12 healthy volunteers (mean age 24±4 years old) underwent 20 minute head-up tilt testing and we measured the temporal changes in left ventricular volume and ejection fraction twice a day (first and second studies). To investigate the changes in the C-VEST measurements and the detector position in the first and second studies, tilt testing was performed with an 80-degree passive tilt, which is the same as the standard procedure used in diagnosing neurally mediated syncope. The coefficient of repeatability for both the C-VEST and detector position was well within the clinical range (coefficient of repeatability in left ventricular volume ranged from 1.7 to 2.8; coefficient of repeatability in the detector position ranged from 2.3 to 3.1). Precise evaluation of the left ventricular volume can be achieved by an ambulatory radionuclide monitoring system in tilt testing. (author)

  13. Assessment of left ventricular function using 201Tl electrocardiogram-gated myocardial single photon emission computed tomography

    International Nuclear Information System (INIS)

    Nishikubo, Naotsugu; Tamai, Hiroyuki

    2013-01-01

    Advances in computed tomography (CT) technology make it possible to obtain left ventricular wall motion using 3D reconstruction. In this study, we compared the images obtained from CT and 201 Tl electrocardiogram (ECG) gated single photon emission computed tomography (SPECT). In 20 patients with ischemic heart disease, we performed 201 Tl ECG gated SPECT (GE Healthcare Millennium VG) and ECG gated CT (Philips Medical Systems Brilliance iCT) to evaluate of left ventricular wall motion during the resting phase. In SPECT, left ventricular images were reconstructed using quantitative gated SPECT (QGS) software. In CT, the images were reconstructed using Virtual Place (AZE Software). The left ventricle was classified into five regions (anterior, lateral, inferior, septal, and apical). The amplitude of the wall motion was classified into five grades according to AHA classification. The values of the wall motion were separately checked by two radiographers. Assessment of left ventricular function myocardial wall movement using the three-dimensional movie display with ECG gated myocardial SPECT data was in agreement with the evaluation by cardiac CT inspection, and corresponded with wall motion in 88 of all 100 segments. SPECT analysis has the same quantity as that of obtained from CT for evaluation of left ventricular wall motion. (author)

  14. Assessment and Mapping of Forest Parcel Sizes

    Science.gov (United States)

    Brett J. Butler; Susan L. King

    2005-01-01

    A method for analyzing and mapping forest parcel sizes in the Northeastern United States is presented. A decision tree model was created that predicts forest parcel size from spatially explicit predictor variables: population density, State, percentage forest land cover, and road density. The model correctly predicted parcel size for 60 percent of the observations in a...

  15. Impacts of acute severe pulmonary regurgitation on right ventricular geometry and contractility assessed by tissue-Doppler echocardiography

    DEFF Research Database (Denmark)

    Kjaergaard, Jesper; K. Iversen, Kasper; G Vejlstrup, Niels

    2010-01-01

    AIMS: Little is known of the impact of acute right ventricular (RV) volume overload on RV function. We assessed the impact of acute severe pulmonary regurgitation (PR) on global and regional RV function by applying novel quantitative echocardiographic markers of myocardial performance in an animal...

  16. Virtual reality 3D echocardiography in the assessment of tricuspid valve function after surgical closure of ventricular septal defect

    NARCIS (Netherlands)

    G. Bol-Raap (Goris); A.H.J. Koning (Anton); T.V. Scohy (Thierry); A.D.J. ten Harkel (Arend); F.J. Meijboom (Folkert); A.P. Kappetein (Arie Pieter); P.J. van der Spek (Peter); A.J.J.C. Bogers (Ad)

    2007-01-01

    textabstractBackground. This study was done to investigate the potential additional role of virtual reality, using three-dimensional (3D) echocardiographic holograms, in the postoperative assessment of tricuspid valve function after surgical closure of ventricular septal defect (VSD). Methods. 12

  17. Impacts of acute severe pulmonary regurgitation on right ventricular geometry and contractility assessed by tissue-Doppler echocardiography

    DEFF Research Database (Denmark)

    Kjaergaard, Jesper; Iversen, Kasper K; Vejlstrup, Niels G

    2010-01-01

    Little is known of the impact of acute right ventricular (RV) volume overload on RV function. We assessed the impact of acute severe pulmonary regurgitation (PR) on global and regional RV function by applying novel quantitative echocardiographic markers of myocardial performance in an animal model....

  18. Clinical impact of left ventricular eccentricity index using cardiac MRI in assessment of right ventricular hemodynamics and myocardial fibrosis in congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Yamasaki, Yuzo; Kamitani, Takeshi; Yamanouchi, Torahiko; Honda, Hiroshi [Kyushu University, Departments of Clinical Radiology, Graduate School of Medical Sciences, Fukuoka (Japan); Nagao, Michinobu; Kawanami, Satoshi [Kyushu University, Molecular Imaging and Diagnosis, Graduate School of Medical Sciences, Fukuoka (Japan); Yamamura, Kenichiro [Kyushu University, Pediatrics, Graduate School of Medical Sciences, Fukuoka (Japan); Sakamoto, Ichiro [Kyushu University, Cardiovascular Medicine, Graduate School of Medical Sciences, Fukuoka (Japan); Yabuuchi, Hidetake [Kyushu University, Health SciencesGraduate School of Medical Sciences, Fukuoka (Japan)

    2016-10-15

    To investigate the utility of eccentricity index (EI) using cardiac cine MRI for the assessment of right ventricular (RV) hemodynamics in congenital heart disease (CHD). Fifty-five patients with CHD (32 women; mean age, 40.7 ± 20.9 years) underwent both cardiac MRI and right heart catheterization. EI was defined as the ratio of the distance between the anterior-posterior wall and the septal-lateral wall measured in the short-axis of mid-ventricular cine MRI. Correlations between EIs and RV hemodynamic parameters were analyzed. EIs were compared between patients with and without late gadolinium enhancement (LGE). A strong correlation between mean pulmonary artery pressure (PAP) and systolic EI (r = 0.81, p < 0.0001) and a moderate negative correlation between diastolic EI and RV ejection fraction (EF) (r = -0.62, p < 0.0001) were observed. Receiver operating characteristic analysis revealed optimal EI thresholds for detecting patients with mean PAP ≥40 mmHg with C-statistics of 0.90 and patients with RVEF <40 % with C-statistics of 0.78. Systolic EIs were significantly greater for patients with LGE (1.45 ± 0.05) than for those without LGE (1.15 ± 0.07; p < 0.001). EI offers a simple, comprehensive index that can predict pulmonary hypertension and RV dysfunction in CHD. (orig.)

  19. The Assessment of Left Ventricular Time-Varying Radius Using Tissue Doppler Imaging

    Directory of Open Access Journals (Sweden)

    Fardin Mirbolouk

    2012-03-01

    Full Text Available Background: Left ventricular twist/torsion is believed to be a sensitive indicator of systolic and diastolic performance. To obtain circumferential rotation using tissue Doppler imaging, we need to estimate the time-varying radius of the left ventricle throughout the cardiac cycle to convert the tangential velocity into angular velocity. Objectives: The aim of this study was to investigate accuracy of measured LV radius using tissue Doppler imaging throughout the cardiac cycle compared to two-dimensional (2D imaging. Methods: A total of 35 subjects (47±12 years old underwent transthoracic echocardiographic standard examinations. Left ventricular radius during complete cardiac cycle measured using tissue Doppler and 2D-imaging at basal and apical short axis levels. For this reason, the 2D-images and velocity-time data derived and transferred to a personal computer for off-line analysis. 2D image frames analyzed via a program written in the MATLAB software. Velocity-time data from anteroseptal at basal level (or anterior wall at apical level and posterior walls transferred to a spreadsheet Excel program for the radius calculations. Linear correlation and Bland-Altman analysis were calculated to assess the relationships and agreements between the tissue Doppler and 2D-measured radii throughout the cardiac cycle. Results: There was significant correlation between tissue Doppler and 2D-measured radii and the Pearson correlation coefficients were 0.84 to 0.97 (P<0.05. Bland-Altman analysis by constructing the 95% limits of agreement showed that the good agreements existed between the two methods. Conclusion: It can be concluded from our experience that the tissue Doppler imaging can reasonably estimate radius of the left ventricle throughout the cardiac cycle.

  20. Assessment of ventricular wall motion with focused echocardiography during cardiac arrest to predict survival

    Directory of Open Access Journals (Sweden)

    Can Ozen

    2016-03-01

    Full Text Available Objectives: Our primary goal is to investigate the hypothesis that in patients with a detectable ventricular wall motion (VWM in cardiac ultrasonography (US during cardiopulmonary resuscitation (CPR, survival rate is significantly more than in patients without VWM in US. Material and methods: In our prospective, single center study, 129 adult cardiac arrest (CA patients were enrolled. Cardiac US according to Focus Assessed Transthoracic Echo (FATE protocol was performed before CPR. Presence of VWM was recorded on forms along with demographic data, initial rhythm, CA location, presence of return of spontaneous circulation (ROSC and time until ROSC was obtained. Results: 129 patients were included. ROSC was obtained in 56/77 (72.7% patients with VWM and 3/52 (5.8% patients without VWM which is statistically significant (p > 0.001. Presence of VWM is 95% (95% CI: 0.95–0.99 sensitive and 70% (95% CI: 0.58–0.80 specific for ROSC. 43/77 (55.8% patients with VWM and 1 (1.9% of 52 patients without VWM survived to hospital admission which was statistically significant (p < 0.001. Presence of VWM was 100% (95% CI: 0.87–1.00 sensitive and 54% (95% CI: 0.43–0.64 specific for survival to hospital admission. Conclusion: No patient without VWM in US survived to hospital discharge. Only 3 had ROSC in emergency department and only 1 survived to hospital admission. This data suggests no patient without VWM before the onset of CPR survived to hospital discharge and this may be an indication to end resuscitative efforts early in these patients. Keywords: Cardiopulmonary resuscitation, Ultrasonography, Echocardiography, Ventricular wall motion

  1. Effects on infarct size and left ventricular function of early intravenous injection of anistreplase in acute myocardial infarction. The APSIM Study Investigators.

    Science.gov (United States)

    Bassand, J P; Bernard, Y; Lusson, J R; Machecourt, J; Cassagnes, J; Borel, E

    1990-03-01

    A total of 231 patients suffering from a first acute myocardial infarction were randomly allocated within 4 hours following the onset of symptoms either to anistreplase or anisoylated plasminogen streptokinase activator complex (APSAC), 30 U over 5 minutes, or to conventional heparin therapy, 5000 IU in bolus injection. Heparin was reintroduced in both groups 4 h after initial therapy at a dosage of 500 IU/kg per day. A total of 112 patients received anistreplase and 119 received heparin within a mean period of 188 +/- 62 min following the onset of symptoms. Infarct size was estimated from single photon emission computerized tomography and expressed in percentage of the total myocardial volume. The patency rate of the infarct-related artery was 77% in the anistreplase group and 36% in the heparin group (p less than 0.001). Left ventricular ejection fraction determined from contrast angiography was significantly higher in the anistreplase group than in the heparin group (6 absolute percentage point difference). A significant 31% reduction in infarct size was found in the anistreplase group (33% for the anterior wall infarction subgroup [p less than 0.05] and 16% for the inferior wall infarction subgroup, NS). A close inverse relation was found between the values of left ventricular ejection fraction and infarct size (r = -.73, p less than 0.01). In conclusion, early infusion of anistreplase in acute myocardial infarction produced a high early patency rate, a significant limitation of infarct size, and a significant preservation of left ventricular systolic function, mainly in the anterior wall infarctions.

  2. Computed tomographic pulmonary angiography in the assessment of severity of chronic thromboembolic pulmonary hypertension and right ventricular dysfunction

    International Nuclear Information System (INIS)

    Liu Min; Ma Zhanhong; Guo Xiaojuan; Zhang Hongxia; Yang Yuanhua; WangChen

    2011-01-01

    Purpose: The aim was to investigate the role of computed tomographic pulmonary angiography (CTPA) in the assessment of severity and right ventricular function in chronic thromboembolic pulmonary hypertension (CTEPH). Materials and methods: Clinical and radiological data of 56 patients with CTEPH January 2006–October 2009 were retrospectively reviewed in the present study. All patients received CTPA with a 64-row CT using the retrospective ECG-Gated mode before digital subtraction pulmonary angiography and right-heart catheterization. CTPA findings including Right Ventricular diameter (RVd) and left ventricular diameter (LVd) were measured at the end diastole. CT Pulmonary Artery Obstruction Indexes including Qanadli Index and Mastora Index were used in the assessment of severity of pulmonary arterial obstruction. Hemodynamic parameters and pulmonary hypertension classification were evaluated by right-heart catheterization in all patients. Right ventricular function was measured with echocardiography in 49 patients. Results: Qanadli Index and Mastora Index respectively were (37.93 ± 14.74)% and (30.92 ± 16.91)%, which showed a significant difference (Z = −5.983, P = 0.000) and a good correlation (r = 0.881, P = 0.000). Neither Qanadli nor Mastora Index correlated with pulmonary hypertension classification (r = −0.009, P = 0.920) or New York Heart Association heart function classification (r = −0.031, P = 0.756). Neither Qanadli nor Mastora Index correlated with any echocardiographic right ventricular parameters (P > 0.05), while RVd/LVd by CTPA correlated with echocardiographic right ventricular functional parameters (P 2 . CTPA findings correlated with hemodynamic variables. Backward linear regression analysis revealed that the RVd/LVd, Right Ventricular Anterior Wall Thickness (RVAWT), Main Pulmonary Artery trunk diameter (MPAd) were shown to be independently associated with mean Pulmonary Artery Pressure (mPAP) levels (model: r 2 = 0.351, P = 0.025; RVd

  3. Quantitative assessment of left ventricular systolic function using 3-dimensional echocardiography

    Directory of Open Access Journals (Sweden)

    Rahul Mehrotra

    2013-09-01

    Full Text Available Assessment of left ventricular systolic function is the commonest and one of the most important indications for performance of echocardiography. It is important for prognostication, determination of treatment plan, for decisions related to expensive device therapies and for assessing response to treatment. The current methods based on two-dimensional echocardiography are not reliable, have high degree of inter-observer and intra-observer variability and are based on presumptions about the geometry of left ventricle (LV. Real-time three-dimensional echocardiography (RT3DE on the other hand is fast, easy, accurate, relatively operator independent and is not based on any assumptions related to the shape of LV. Owing to these advantages, it is the Echocardiographic modality of choice for assessment of systolic function of the LV. We describe here a step by step approach to evaluation of LV volumes, ejection fraction, regional systolic function and Dyssynchrony analysis based on RT3DE. It has been well validated in clinical studies and is rapidly being incorporated in routine clinical practice.

  4. Computer-assisted determination of left ventricular endocardial borders reduces variability in the echocardiographic assessment of ejection fraction

    Directory of Open Access Journals (Sweden)

    Lindstrom Lena

    2008-11-01

    Full Text Available Abstract Background Left ventricular size and function are important prognostic factors in heart disease. Their measurement is the most frequent reason for sending patients to the echo lab. These measurements have important implications for therapy but are sensitive to the skill of the operator. Earlier automated echo-based methods have not become widely used. The aim of our study was to evaluate an automatic echocardiographic method (with manual correction if needed for determining left ventricular ejection fraction (LVEF based on an active appearance model of the left ventricle (syngo®AutoEF, Siemens Medical Solutions. Comparisons were made with manual planimetry (manual Simpson, visual assessment and automatically determined LVEF from quantitative myocardial gated single photon emission computed tomography (SPECT. Methods 60 consecutive patients referred for myocardial perfusion imaging (MPI were included in the study. Two-dimensional echocardiography was performed within one hour of MPI at rest. Image quality did not constitute an exclusion criterion. Analysis was performed by five experienced observers and by two novices. Results LVEF (%, end-diastolic and end-systolic volume/BSA (ml/m2 were for uncorrected AutoEF 54 ± 10, 51 ± 16, 24 ± 13, for corrected AutoEF 53 ± 10, 53 ± 18, 26 ± 14, for manual Simpson 51 ± 11, 56 ± 20, 28 ± 15, and for MPI 52 ± 12, 67 ± 26, 35 ± 23. The required time for analysis was significantly different for all four echocardiographic methods and was for uncorrected AutoEF 79 ± 5 s, for corrected AutoEF 159 ± 46 s, for manual Simpson 177 ± 66 s, and for visual assessment 33 ± 14 s. Compared with the expert manual Simpson, limits of agreement for novice corrected AutoEF was lower than for novice manual Simpson (0.8 ± 10.5 vs. -3.2 ± 11.4 LVEF percentage points. Calculated for experts and with LVEF (% categorized into Conclusion Corrected AutoEF reduces the variation in measurements compared with

  5. Non-invasive assessment of right ventricular function at rest and on exercise in obstructive airways disease

    International Nuclear Information System (INIS)

    Tweddel, A.; Martin, W.; McGhie, I.; Neilly, B.; Stevenson, R.; Hutton, I.

    1985-01-01

    Non-invasive assessment of right ventricular function is of clinical interest in the patient with obstructive airways disease. Gated Xenon 133 scanning allows right ventricular function to be evaluated in isolation from the left ventricle, and with rapid clearance from the lungs, scans may be repeated within 5 minutes. 400mBq of Xenon 133 were injected intravenously over 20 seconds and images were obtained using a mobile gamma camera. Maximal symptom limited exercise was performed on a supine bicycle ergometer. The normal range for right ventricular ejection fraction (RVEF) was obtained from 10 volunteers - 40-55% at rest rising by 5-15% during exercise. In 10 patients with acute obstructive airways disease, all had reduced RVEF 21 +- 3%. In chronic obstructive airways disease, if resting RVEF was greater than 30%, ejection fraction increased on exercise. If resting ejection fraction was abnormal than RVEF was reduced or unchanged on exercise (mean 15 +- 9%), and this was associated with dilatation of both the right ventricle and atrium. In conclusion, gated Xenon 133 offers a simple method of assessing right ventricular function at rest and on exercise in the patient with obstructive airways disease

  6. Assessment of left ventricular function by 201Tl FCG-gated myocardial SPECT

    International Nuclear Information System (INIS)

    Toba, Masahiro; Ishida, Yoshio; Fukuchi, Kazuki; Fukushima, Kazuhito; Katafuchi, Tetsurou; Hayashida, Kohei; Oka, Hisashi; Takamiya, Makoto

    1999-01-01

    We applied the QGS program for LV function analysis (described by Germano, 1995) to a 201 Tl SPECT study at rest, and estimated its accuracy. We performed 201 Tl ECG-gated myocardial SPECT in 25 patients with ischemic heart disease under an acquisition time used in the routine 99m Tc ECG-gated SPECT study. The quality of the gated images was visually assessed with a 4-point grading system. LVEDV, LVESV, LVEF determined by the QGS program were compared with those by Simpson's method on biplane LVG in 25 patients. Regional wall motion scores in 7 myocardial segments were assessed on the three-dimensional display created by the QGS program and the cine display of biplane LVG with a 5-point grading system. Wall motion scores obtained by the QGS program were compared with those by LVG. Although 72.0% of 201 Tl ECG-gated SPECT images were fair or poor in image quality, there were good correlations between the values obtained by the QGS program and LVG (LVEDV: r=0.82, LVESV: r=0.88, LVEF: r=0.89). In addition, wall motion scores by the QGS program were correspondent to those by LVG in 77.1% of all 175 myocardial segments. We conclude that the QGS program provides high accuracy in evaluating left ventricular function even from 201 Tl ECG-gated myocardial SPECT data. (author)

  7. Impedance cardiography: a comparison of cardiac output vs waveform analysis for assessing left ventricular systolic dysfunction.

    Science.gov (United States)

    DeMarzo, Arthur P; Kelly, Russell F; Calvin, James E

    2007-01-01

    Early detection of asymptomatic left ventricular systolic dysfunction (LVSD) is beneficial in managing heart failure. Recent studies have cast doubt on the usefulness of cardiac output as an indicator of LVSD. In impedance cardiography (ICG), the dZ/dt waveform has a systolic wave called the E wave. This study looked at measurements of the amplitude and area of the E wave compared with ICG-derived cardiac output, stroke volume, cardiac index, and stroke index as methods of assessing LVSD. ICG data were obtained from patients (n=26) admitted to a coronary care unit. Clinical LVSD severity was stratified into 4 groups (none, mild, moderate, and severe) based on echocardiography data and standard clinical assessment by a cardiologist blinded to ICG data. Statistical analysis showed that the E wave amplitude and area were better indicators of the level of LVSD than cardiac output, stroke volume, cardiac index, or stroke index. ICG waveform analysis has potential as a simple point-of-care test for detecting LVSD in asymptomatic patients at high risk for developing heart failure and for monitoring LVSD in patients being treated for heart failure.

  8. Left atrial strain: a new parameter for assessment of left ventricular filling pressure.

    Science.gov (United States)

    Cameli, Matteo; Mandoli, Giulia Elena; Loiacono, Ferdinando; Dini, Frank Lloyd; Henein, Michael; Mondillo, Sergio

    2016-01-01

    In order to obtain accurate diagnosis, treatment and prognostication in many cardiac conditions, there is a need for assessment of left ventricular (LV) filling pressure. While systole depends on ejection function of LV, diastole and its disturbances influence filling function and pressures. The commonest condition that represents the latter is heart failure with preserved ejection fraction in which LV ejection is maintained, but diastole is disturbed and hence filling pressures are raised. Significant diastolic dysfunction results in raised LV end-diastolic pressure, mean left atrial (LA) pressure and pulmonary capillary wedge pressure, all referred to as LV filling pressures. Left and right heart catheterization has traditionally been used as the gold standard investigation for assessing these pressures. More recently, Doppler echocardiography has taken over such application because of its noninvasive nature and for being patient friendly. A number of indices are used to achieve accurate assessment of filling pressures including: LV pulsed-wave filling velocities (E/A ratio, E wave deceleration time), pulmonary venous flow (S wave and D wave), tissue Doppler imaging (E' wave and E/E' ratio) and LA volume index. LA longitudinal strain derived from speckle tracking echocardiography (STE) is also sensitive in estimating intracavitary pressures. It is angle-independent, thus overcomes Doppler limitations and provides highly reproducible measures of LA deformation. This review examines the application of various Doppler echocardiographic techniques in assessing LV filling pressures, in particular the emerging role of STE in assessing LA pressures in various conditions, e.g., HF, arterial hypertension and atrial fibrillation.

  9. Assessment of the left ventricular systolic and diastolic function by the left ventricular density curve derived from intravenous digital subtraction angiography in children

    International Nuclear Information System (INIS)

    Horigome, Hitoshi; Satoh, Hideo; Isobe, Takeshi; Takita, Hitoshi

    1991-01-01

    To evaluate the left ventricular (LV) systolic and diastolic function, fifty-four children with various heart diseases underwent intravenous digital subtraction angiography (IV-DSA). Global left ventricular density curve was obtained through densitometry of the DSA images. The curve was smoothed by a third-degree Fourier transformation and systolic and diastolic indexes were obtained. In the control group, consisting of Kawasaki disease without coronary lesion and mild pulmonary stenosis, the peak ejection rate (PER) and the peak filling rate in early diastole (PFR-E) correlated positively with the heart rate (HR) in a quadratic curve manner [PER: r= 0.93 p<0.01, PFR-E: r= 0.94 p<0.01]. Time from end-diastolic to PER (T-PER) and time from end-systolic to PFR (T-PFR) were correlated negatively with HR [T-PER: r=-0.86 p<0.01, T-PFR: r=-0.91 p<0.01]. However, T-PER/RR and T-PFR/RR values were rather constant (20.9±3.2%, 17.0±2.6%, respectively). We also found significant correlations of PER and PFR-E with left ventricular ejection fraction (LVEF). Patients with corrected tetralogy of Fallot and with cardiomyopaties showed not only abnormal systolic indexes but some depressed diastolic indexes. LV density curve also disclosed isolated diastolic dysfunction in a group of aortic stenosis and in two patients with coronary lesions. A correlation of LVEF derived from the density curve and conventional area-length method was high [r= 0.91 p<0.001]. To evaluate the reproducibility, we were able to obtain the digital data twice with over one month interval on 24 patients. The intraobserver correlation was satisfactory. We applied the remasking method, resulting in improving the quality of digital images under spontaneous breathing. Our results indicated that IV-DSA was a less-invasive and clinically reliable method for assessment of LV function in children. (author)

  10. Assessment of the left ventricular systolic and diastolic function by the left ventricular density curve derived from intravenous digital subtraction angiography in children

    Energy Technology Data Exchange (ETDEWEB)

    Horigome, Hitoshi; Satoh, Hideo; Isobe, Takeshi; Takita, Hitoshi (Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine)

    1991-05-01

    To evaluate the left ventricular (LV) systolic and diastolic function, fifty-four children with various heart diseases underwent intravenous digital subtraction angiography (IV-DSA). Global left ventricular density curve was obtained through densitometry of the DSA images. The curve was smoothed by a third-degree Fourier transformation and systolic and diastolic indexes were obtained. In the control group, consisting of Kawasaki disease without coronary lesion and mild pulmonary stenosis, the peak ejection rate (PER) and the peak filling rate in early diastole (PFR-E) correlated positively with the heart rate (HR) in a quadratic curve manner (PER: r= 0.93 p<0.01, PFR-E: r= 0.94 p<0.01). Time from end-diastolic to PER (T-PER) and time from end-systolic to PFR (T-PFR) were correlated negatively with HR (T-PER: r=-0.86 p<0.01, T-PFR: r=-0.91 p<0.01). However, T-PER/RR and T-PFR/RR values were rather constant (20.9+-3.2%, 17.0+-2.6%, respectively). We also found significant correlations of PER and PFR-E with left ventricular ejection fraction (LVEF). Patients with corrected tetralogy of Fallot and with cardiomyopaties showed not only abnormal systolic indexes but some depressed diastolic indexes. LV density curve also disclosed isolated diastolic dysfunction in a group of aortic stenosis and in two patients with coronary lesions. A correlation of LVEF derived from the density curve and conventional area-length method was high (r= 0.91 p<0.001). To evaluate the reproducibility, we were able to obtain the digital data twice with over one month interval on 24 patients. The intraobserver correlation was satisfactory. We applied the remasking method, resulting in improving the quality of digital images under spontaneous breathing. Our results indicated that IV-DSA was a less-invasive and clinically reliable method for assessment of LV function in children. (author).

  11. Echocardiographic assessment with right ventricular function improvement following ultrasound-accelerated catheter-directed thrombolytic therapy in submassive pulmonary embolism.

    Science.gov (United States)

    Doheny, Charles; Gonzalez, Lorena; Duchman, Stanley M; Varon, Joseph; Bechara, Carlos F; Cheung, Mathew; Lin, Peter H

    2018-06-01

    Introduction The objective of this study was to evaluate the efficacy of ultrasound-accelerated catheter-directed thrombolytic therapy in patients with submassive pulmonary embolism. Methods Clinical records of 46 patients with submassive pulmonary embolism who underwent ultrasound-accelerated catheter-directed pulmonary thrombolysis using tissue plasminogen activator, from 2007 to 2017, were analyzed. All patients experienced clinical symptoms with computed tomography evidence of pulmonary thrombus burden. Right ventricular dysfunction was present in all patients by echocardiographic finding of right ventricle-to-left ventricle ratio > 0.9. Treatment outcome, procedural complications, right ventricular pressures, and thrombus clearance were evaluated. Follow-up evaluation included echocardiographic assessment of right ventricle-to-left ventricle ratio at one month, six months, and one year. Results Technical success was achieved in all patients ( n = 46, 100%). Our patients received an average of 18.4 ± 4.7 mg of tissue plasminogen activator using ultrasound-accelerated thrombolytic catheter with an average infusion time of 16.5± 5.4 h. Clinical success was achieved in all patients (100%). Significant reduction of mean pulmonary artery pressure occurred following the treatment, which decreased from 36 ± 8 to 21 ± 5 mmHg ( p right ventricular dysfunction based on echocardiographic assessment. The right ventricle-to-left ventricle ratio decreased from 1.32 ± 0.18 to 0.91 ± 0.13 at the time of hospital discharge ( p right ventricular function remained improved at 6 months and 12 months of follow-up, as right ventricle-to-left ventricle ratio were 0.92 ± 0.14 ( p right ventricular function in patients with submassive pulmonary embolism.

  12. Assessment of left ventricular function in patients with atrial fibrillation by left ventricular filling and function curves determined by ECG gated blood pool scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Suetsugu

    1986-06-01

    Accurate cardiac function in patients with atrial fibrillation (Af) is difficult to assess, since a wide fluctuation of cardiac cycle makes the ventricular hemodynamics variable. Although ECG gated blood pool scintigraphy (EGBPS) is useful to evaluate left ventricular (LV) function, a conventional EGBPS might have a problem in applying to Af. Therefore, a new processing algorithm was devised to make multiple gated images discriminated by preceding R-R intervals (PRR), and LV filling and function curves were obtained in 62 patients with Af to evaluate LV function. LV filling curve, obtained by plotting end-diastolic volume (EDV) againt PRR, demonstrated that the blood filling was impaired in mitral stenosis and constrictive pericarditis, but recovered after mitral commissurotomy. LV function curve, by plotting stroke volume (SV) againt EDV, was quantitatively analysed by the indices such as Slope and Position. Both indices reduced significantly in heart failure. When compared among underlying diseases individually, the indices decreased in the following order; lone Af, hyperthyroidism, senile Af, hypertension, mitral valve disease, ischemic heart disease, dilated cardiomyopathy and aortic regurgitation. After the treatment with digitalis and/or diuretics, left and upward shift of function curve was observed. The rise in heart rate by atropine infusion made Slope and Position unchanged, and which implied that function curve was little influenced by heart rate per se. The rise in systolic blood pressure by angiotensin-II infusion caused shifts in function curve to rightward and downward. Downward shift, mostly seen in patients with gentler slope in control state, may imply afterload mismatch due to a decrease in preload reserve. (J.P.N.).

  13. Added clinical value of applying myocardial deformation imaging to assess right ventricular function.

    Science.gov (United States)

    Sokalskis, Vladislavs; Peluso, Diletta; Jagodzinski, Annika; Sinning, Christoph

    2017-06-01

    Right heart dysfunction has been found to be a strong prognostic factor predicting adverse outcome in various cardiopulmonary diseases. Conventional echocardiographic measurements can be limited by geometrical assumptions and impaired reproducibility. Speckle tracking-derived strain provides a robust quantification of right ventricular function. It explicitly evaluates myocardial deformation, as opposed to tissue Doppler-derived strain, which is computed from tissue velocity gradients. Right ventricular longitudinal strain provides a sensitive tool for detecting right ventricular dysfunction, even at subclinical levels. Moreover, the longitudinal strain can be applied for prognostic stratification of patients with pulmonary hypertension, pulmonary embolism, and congestive heart failure. Speckle tracking-derived right atrial strain, right ventricular longitudinal strain-derived mechanical dyssynchrony, and three-dimensional echocardiography-derived strain are emerging imaging parameters and methods. Their application in research is paving the way for their clinical use. © 2017, Wiley Periodicals, Inc.

  14. Assessment of left ventricular function and mass in dual-source computed tomography coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Christoph J., E-mail: c.jensen@contilia.d [Department of Cardiology and Angiology, Elisabeth Hospital, Essen (Germany); Jochims, Markus [Department of Cardiology and Angiology, Elisabeth Hospital, Essen (Germany); Hunold, Peter; Forsting, Michael; Barkhausen, Joerg [Department of Diagnostic and Interventional Radiology and Neuroradiology, University of Essen (Germany); Sabin, Georg V.; Bruder, Oliver [Department of Cardiology and Angiology, Elisabeth Hospital, Essen (Germany); Schlosser, Thomas [Department of Diagnostic and Interventional Radiology and Neuroradiology, University of Essen (Germany)

    2010-06-15

    Purpose: To quantify left ventricular (LV) function and mass (LVM) derived from dual-source computed tomography (DSCT) and the influence of beta-blocker administration compared to cardiac magnetic resonance imaging (CMR). Methods: Thirty-two patients undergoing cardiac DSCT and CMR were included, where of fifteen received metoprolol intravenously before DSCT. LV parameters were calculated by the disc-summation method (DSM) and by a segmented region-growing algorithm (RGA). All data sets were analyzed by two blinded observers. Interobserver agreement was tested by the intraclass correlation coefficient. Results.: 1. Using DSM LV parameters were not statistically different between DSCT and CMR in all patients (DSCT vs. CMR: EF 63 {+-} 8% vs. 64 {+-} 8%, p = 0.47; EDV 136 {+-} 36 ml vs. 138 {+-} 35 ml, p = 0.66; ESV 52 {+-} 21 ml vs. 52 {+-} 22 ml, p = 0.61; SV 83 {+-} 22 ml vs. 87 {+-} 19 ml, p = 0.22; CO 5.4 {+-} 0.9 l/min vs. 5.7 {+-} 1.2 l/min, p = 0.09, LVM 132 {+-} 33 g vs. 132 {+-} 33 g, p = 0.99). 2. In a subgroup of 15 patients beta-blockade prior to DSCT resulted in a lower ejection fraction (EF), stroke volume (SV), cardiac output (CO) and increase in end systolic volume (ESV) in DSCT (EF 59 {+-} 8% vs. 62 {+-} 9%; SV 73 {+-} 17 ml vs. 81 {+-} 15 ml; CO 5.7 {+-} 1.2 l/min vs. 5.0 {+-} 0.8 l/min; ESV 52 {+-} 27 ml vs. 57 {+-} 24 ml, all p < 0.05). 3. Analyzing the RGA parameters LV volumes were not significantly different compared to DSM, whereas LVM was higher using RGA (177 {+-} 31 g vs. 132 {+-} 33 g, p < 0.05). Interobserver agreement was excellent comparing DSM values with best agreement between RGA calculations. Conclusion: Left ventricular volumes and mass can reliably be assessed by DSCT compared to CMR. However, beta-blocker administration leads to statistically significant reduced EF, SV and CO, whereas ESV significantly increases. DSCT RGA reliably analyzes LV function, whereas LVM is overestimated compared to DSM.

  15. Exploratory assessment of left ventricular strain–volume loops in severe aortic valve diseases

    Science.gov (United States)

    Hulshof, Hugo G.; van Dijk, Arie P.; George, Keith P.; Hopman, Maria T. E.; Thijssen, Dick H. J.

    2017-01-01

    Key points Severe aortic valve diseases are common cardiac abnormalities that are associated with poor long‐term survival.Before any reduction in left ventricular (LV) function, the left ventricle undergoes structural remodelling under the influence of changing haemodynamic conditions.In this study, we combined temporal changes in LV structure (volume) with alterations in LV functional characteristics (strain, ԑ) into a ԑ–volume loop, in order to provide novel insight into the haemodynamic cardiac consequences of aortic valve diseases in those with preserved LV ejection fraction.We showed that our novel ԑ–volume loop and the specific loop characteristics provide additional insight into the functional and mechanical haemodynamic consequences of severe aortic valve diseases (with preserved LV ejection fraction).Finally, we showed that the ԑ–volume loop characteristics provide discriminative capacity compared with conventional measures of LV function. Abstract The purpose of this study was to examine left ventricular (LV) strain (ԑ)–volume loops to provide novel insight into the haemodynamic cardiac consequences of aortic valve stenosis (AS) and aortic valve regurgitation (AR). Twenty‐seven participants were retrospectively recruited: AR (n = 7), AS (n = 10) and control subjects (n = 10). Standard transthoracic echocardiography was used to obtain apical four‐chamber images to construct ԑ–volume relationships, which were assessed using the following parameters: early systolic ԑ (ԑ_ES); slope of ԑ–volume relationship during systole (Sslope); end‐systolic peak ԑ (peak ԑ); and diastolic uncoupling (systolic ԑ–diastolic ԑ at same volume) during early diastole (UNCOUP_ED) and late diastole (UNCOUP_LD). Receiver operating characteristic curves were used to determine the ability to detect impaired LV function. Although LV ejection fraction was comparable between groups, longitudinal peak ԑ was reduced compared with control subjects

  16. Exploratory assessment of left ventricular strain-volume loops in severe aortic valve diseases.

    Science.gov (United States)

    Hulshof, Hugo G; van Dijk, Arie P; George, Keith P; Hopman, Maria T E; Thijssen, Dick H J; Oxborough, David L

    2017-06-15

    Severe aortic valve diseases are common cardiac abnormalities that are associated with poor long-term survival. Before any reduction in left ventricular (LV) function, the left ventricle undergoes structural remodelling under the influence of changing haemodynamic conditions. In this study, we combined temporal changes in LV structure (volume) with alterations in LV functional characteristics (strain, ԑ) into a ԑ-volume loop, in order to provide novel insight into the haemodynamic cardiac consequences of aortic valve diseases in those with preserved LV ejection fraction. We showed that our novel ԑ-volume loop and the specific loop characteristics provide additional insight into the functional and mechanical haemodynamic consequences of severe aortic valve diseases (with preserved LV ejection fraction). Finally, we showed that the ԑ-volume loop characteristics provide discriminative capacity compared with conventional measures of LV function. The purpose of this study was to examine left ventricular (LV) strain (ԑ)-volume loops to provide novel insight into the haemodynamic cardiac consequences of aortic valve stenosis (AS) and aortic valve regurgitation (AR). Twenty-seven participants were retrospectively recruited: AR (n = 7), AS (n = 10) and control subjects (n = 10). Standard transthoracic echocardiography was used to obtain apical four-chamber images to construct ԑ-volume relationships, which were assessed using the following parameters: early systolic ԑ (ԑ_ES); slope of ԑ-volume relationship during systole (Sslope); end-systolic peak ԑ (peak ԑ); and diastolic uncoupling (systolic ԑ-diastolic ԑ at same volume) during early diastole (UNCOUP_ED) and late diastole (UNCOUP_LD). Receiver operating characteristic curves were used to determine the ability to detect impaired LV function. Although LV ejection fraction was comparable between groups, longitudinal peak ԑ was reduced compared with control subjects. In contrast, ԑ_ES and Sslope were

  17. Assessment of left ventricular function and mass in dual-source computed tomography coronary angiography

    International Nuclear Information System (INIS)

    Jensen, Christoph J.; Jochims, Markus; Hunold, Peter; Forsting, Michael; Barkhausen, Joerg; Sabin, Georg V.; Bruder, Oliver; Schlosser, Thomas

    2010-01-01

    Purpose: To quantify left ventricular (LV) function and mass (LVM) derived from dual-source computed tomography (DSCT) and the influence of beta-blocker administration compared to cardiac magnetic resonance imaging (CMR). Methods: Thirty-two patients undergoing cardiac DSCT and CMR were included, where of fifteen received metoprolol intravenously before DSCT. LV parameters were calculated by the disc-summation method (DSM) and by a segmented region-growing algorithm (RGA). All data sets were analyzed by two blinded observers. Interobserver agreement was tested by the intraclass correlation coefficient. Results.: 1. Using DSM LV parameters were not statistically different between DSCT and CMR in all patients (DSCT vs. CMR: EF 63 ± 8% vs. 64 ± 8%, p = 0.47; EDV 136 ± 36 ml vs. 138 ± 35 ml, p = 0.66; ESV 52 ± 21 ml vs. 52 ± 22 ml, p = 0.61; SV 83 ± 22 ml vs. 87 ± 19 ml, p = 0.22; CO 5.4 ± 0.9 l/min vs. 5.7 ± 1.2 l/min, p = 0.09, LVM 132 ± 33 g vs. 132 ± 33 g, p = 0.99). 2. In a subgroup of 15 patients beta-blockade prior to DSCT resulted in a lower ejection fraction (EF), stroke volume (SV), cardiac output (CO) and increase in end systolic volume (ESV) in DSCT (EF 59 ± 8% vs. 62 ± 9%; SV 73 ± 17 ml vs. 81 ± 15 ml; CO 5.7 ± 1.2 l/min vs. 5.0 ± 0.8 l/min; ESV 52 ± 27 ml vs. 57 ± 24 ml, all p < 0.05). 3. Analyzing the RGA parameters LV volumes were not significantly different compared to DSM, whereas LVM was higher using RGA (177 ± 31 g vs. 132 ± 33 g, p < 0.05). Interobserver agreement was excellent comparing DSM values with best agreement between RGA calculations. Conclusion: Left ventricular volumes and mass can reliably be assessed by DSCT compared to CMR. However, beta-blocker administration leads to statistically significant reduced EF, SV and CO, whereas ESV significantly increases. DSCT RGA reliably analyzes LV function, whereas LVM is overestimated compared to DSM.

  18. Assessment of cardiac morphology and ventricular function in healthy Chinese individuals using MRI

    International Nuclear Information System (INIS)

    Lu Minjie; Zhao Shihua; Jiang Shiliang

    2011-01-01

    Objective: To investigate reproducibility of cardiac MRI for assessment of cardiac morphology and ventricular function in selected normal Chinese Han population. Methods: Two hundred and sixty-nine normal volunteers underwent cardiac MRI using a 1.5 T MR system. HASTE and steady state free precession imaging were performed with long and short axis images and cine mode through the ventricle with wireless vector cardiac gating. The images were reviewed by two independent observers. The dimensions of cardiac chambers and ventricular function including ejection fraction (EF), end diastolic volume (EDV) , end systolic volume (ESV) and myocardial mass were evaluated. The data between male and female were compared by using two-tailed unpaired t test. Results: Total imaging time was (15±3) min. The anteroposterior diameter of the left atrium was (2.87±0.77) cm, the right atrial diameter perpendicular to the atrial septum was (3.61±0.57) cm, the end diastolic diameter of the left ventricle was (4.97± 0.52) cm, the end diastolic diameter of the right ventricle was (2.65±0.48) cm. On the left ventricle, EF was (60.62±7.08)%, EDV was (115.37±26.71) ml, ESV was (46.02±15.72) ml and LV mass was (82.97±24.03) g. On the right ventricle, EF was (47.73±6.50)%, EDV was (128.27±32.16) ml, ESV was (67.7±21.07) ml and RV mass was (48.24±13.42) g. There were no statistically significant differences in LVESV (P=0.144), LVEDV index (P=0.714), LVESV index (P=0.113), LVCI (P=0.199), RVEF (P=0.296) and RV mass (P=0.093), and statistically significant differences in other cardiac parameters between male and female. Conclusion: Cardiac MRI can provide useful information about cardiac function and morphology with a high level of reproducibility in normal Chinese Han population. (authors)

  19. Normal nonuniformity of left ventricular contraction. Assessment by cine MR imaging with presaturation myocardial tagging

    International Nuclear Information System (INIS)

    Naito, H.; Arisawa, J.; Harada, K.; Yamagami, H.; Kozuka, T.; Tamura, S.

    1996-01-01

    Purpose: To identify the normal performance of left ventricular (LV) regional contraction using cine MR imaging with presaturation myocardial tagging. Material and Methods: Sixteen normal volunteers were examined on a 1.5 T MR system with tagging cine sequences. Tags were applied at end-diastole as 2 parallel black lines on short-axis and 4-chamber sections, and the fractional shortenings were calculated at 7 LV locations. Results: The following results were obtained with significance: A transmural gradient of contractility in the short-axis section; prolonged late-systolic endocardial shortening and epicardial early termination in the free wall; initial delay of shortening in the anterior wall; apical predominance of contractility; predominance of circumferential shortening in the free wall and of meridional shortening in the septum. These findings could be associated with myocardial fiber architecture, presumed wall stress and temporal asynergy of excitation. Conclusion: Cine MR imaging with myocardial tagging proved to be useful in assessing the nonuniformity of LV contraction. (orig.)

  20. Performance of Noninvasive Assessment in the Diagnosis of Right Heart Failure After Left Ventricular Assist Device.

    Science.gov (United States)

    Joly, Joanna M; El-Dabh, Ashraf; Marshell, Ramey; Chatterjee, Arka; Smith, Michelle G; Tresler, Margaret; Kirklin, James K; Acharya, Deepak; Rajapreyar, Indranee N; Tallaj, José A; Pamboukian, Salpy V

    2018-06-01

    Right heart failure (RHF) after left ventricular assist device (LVAD) is associated with poor outcomes. Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) defines RHF as elevated right atrial pressure (RAP) plus venous congestion. The purpose of this study was to examine the diagnostic performance of the noninvasive INTERMACS criteria using RAP as the gold standard. We analyzed 108 patients with LVAD who underwent 341 right heart catheterizations (RHC) between January 1, 2006, and December 31, 2013. Physical exam, echocardiography, and laboratory data at the time of RHC were collected. Conventional two-by-two tables were used and missing data were excluded. The noninvasive INTERMACS definition of RHF is 32% sensitive (95% CI, 0.21-0.44) and 97% specific (95% CI, 0.95-0.99) for identifying elevated RAP. Clinical assessment failed to identify two-thirds of LVAD patients with RAP > 16 mm Hg. More than half of patients with elevated RAP did not have venous congestion, which may represent a physiologic opportunity to mitigate the progression of disease before end-organ damage occurs. One-quarter of patients who met the noninvasive definition of RHF did not actually have elevated RAP, potentially exposing patients to unnecessary therapies. In practice, if any component of the INTERMACS definition is present or equivocal, our data suggest RHC is warranted to establish the diagnosis.

  1. Assessment of left ventricular myocardial scar with three-dimensional MRI

    International Nuclear Information System (INIS)

    Yin Gang; Zhao Shihua; Lu Minjie

    2011-01-01

    Objective: To assess the value of free-breathing 3D phase sensitive inversion recovery (PSIR) turbo FLASH for demonstrating the left ventricular myocardial scar in patients with myocardial infarction. Methods: Twenty-three patients with myocardial infarction underwent 2D and 3D phase sensitive inversion recovery (PSIR) Turbo FLASH sequences 10-15 minutes after injection of dimeglumine gadopentetate. The image quality, the area, location and volume of hyperenhanced scar were independently assessed by two experienced radiologists. Student's t test or rank sum test and Pearson linear correlation were used for the statistics. Results: There were no significant differences in the overall image quality (2.57± 0.59 vs 2.39±0.66, Z=-0.93, P=0.35), the area (24.48±10.83 vs 29.00±11.56, Z=-1.41, P=0.16) and location (16.78±6.51 vs 18.87±6.76, Z=-1.17, P=0.24) of hyperenhanced scar between 2D and 3D PSIR sequences. The mean volume of hyperenhanced scar was significantly greater in 3D PSIR sequence than that in 2D PSIR sequence [(23.46±10.61) vs (31.65±13.86) cm 3 , t=-2.25, P= 0.03]. There was a good correlation in the volume of hyperenhanced scar between 2D PSIR and 3D PSIR sequences (r=0.940, P 2 =0.883). Conclusion: Free-breathing 3D PSIR Turbo FLASH is a promising new imaging technique for accurate assessment of myocardial scar. (authors)

  2. Optimal left ventricular lead position assessed with phase analysis on gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Boogers, Mark J.; Chen, Ji; Garcia, Ernest V.; Bommel, Rutger J. van; Borleffs, C.J.W.; Schalij, Martin J.; Wall, Ernst E. van der; Bax, Jeroen J.; Dibbets-Schneider, Petra; Hiel, Bernies van der; Younis, Imad Al

    2011-01-01

    The aim of the current study was to evaluate the relationship between the site of latest mechanical activation as assessed with gated myocardial perfusion SPECT (GMPS), left ventricular (LV) lead position and response to cardiac resynchronization therapy (CRT). The patient population consisted of consecutive patients with advanced heart failure in whom CRT was currently indicated. Before implantation, 2-D echocardiography and GMPS were performed. The echocardiography was performed to assess LV end-systolic volume (LVESV), LV end-diastolic volume (LVEDV) and LV ejection fraction (LVEF). The site of latest mechanical activation was assessed by phase analysis of GMPS studies and related to LV lead position on fluoroscopy. Echocardiography was repeated after 6 months of CRT. CRT response was defined as a decrease of ≥15% in LVESV. Enrolled in the study were 90 patients (72% men, 67±10 years) with advanced heart failure. In 52 patients (58%), the LV lead was positioned at the site of latest mechanical activation (concordant), and in 38 patients (42%) the LV lead was positioned outside the site of latest mechanical activation (discordant). CRT response was significantly more often documented in patients with a concordant LV lead position than in patients with a discordant LV lead position (79% vs. 26%, p<0.01). After 6 months, patients with a concordant LV lead position showed significant improvement in LVEF, LVESV and LVEDV (p<0.05), whereas patients with a discordant LV lead position showed no significant improvement in these variables. Patients with a concordant LV lead position showed significant improvement in LV volumes and LV systolic function, whereas patients with a discordant LV lead position showed no significant improvements. (orig.)

  3. Virtual reality 3D echocardiography in the assessment of tricuspid valve function after surgical closure of ventricular septal defect

    Directory of Open Access Journals (Sweden)

    Kappetein A Pieter

    2007-02-01

    Full Text Available Abstract Background This study was done to investigate the potential additional role of virtual reality, using three-dimensional (3D echocardiographic holograms, in the postoperative assessment of tricuspid valve function after surgical closure of ventricular septal defect (VSD. Methods 12 data sets from intraoperative epicardial echocardiographic studies in 5 operations (patient age at operation 3 weeks to 4 years and bodyweight at operation 3.8 to 17.2 kg after surgical closure of VSD were included in the study. The data sets were analysed as two-dimensional (2D images on the screen of the ultrasound system as well as holograms in an I-space virtual reality (VR system. The 2D images were assessed for tricuspid valve function. In the I-Space, a 6 degrees-of-freedom controller was used to create the necessary projectory positions and cutting planes in the hologram. The holograms were used for additional assessment of tricuspid valve leaflet mobility. Results All data sets could be used for 2D as well as holographic analysis. In all data sets the area of interest could be identified. The 2D analysis showed no tricuspid valve stenosis or regurgitation. Leaflet mobility was considered normal. In the virtual reality of the I-Space, all data sets allowed to assess the tricuspid leaflet level in a single holographic representation. In 3 holograms the septal leaflet showed restricted mobility that was not appreciated in the 2D echocardiogram. In 4 data sets the posterior leaflet and the tricuspid papillary apparatus were not completely included. Conclusion This report shows that dynamic holographic imaging of intraoperative postoperative echocardiographic data regarding tricuspid valve function after VSD closure is feasible. Holographic analysis allows for additional tricuspid valve leaflet mobility analysis. The large size of the probe, in relation to small size of the patient, may preclude a complete data set. At the moment the requirement of an I

  4. The assessment of size in fossil felidae

    Directory of Open Access Journals (Sweden)

    O' Regan, H.

    2002-04-01

    Full Text Available Estimations of body size in fossil vertebrates depend on establishing the relationships between body mass, overall length or some measure of stature and measurements taken on skeletal elements in living relatives or close proxies. However, most osteological collections lack information on body size for individual specimens, and published investigations usually fa11 back on summary data derived from the literature to plot against measurements taken directly on the skeletal material. The utility of such approaches beyond very general indications of size is open to question. In an effort to reduce these problems we attempt to establish some objective basis for using skeletal elements for the purpose of size estimation in the larger Felidae of the genus Panthera, using data for the jaguar, Panthera onca. We show that cranial length offers a good indication of overall size in the living animal, and that various other cranial dimensions correlate closely with that measurement, while individual teeth, despite their frequent occurrence in assemblages, show a looser relationship and therefore appear less useful for size estimations of fossil material than has been thought.Las estimaciones de la talla corporal en vertebrados fósiles depende de las relaciones establecidas entre el peso corporal, la longitud total o alguna medida de estatura tomada de los elementos esqueléticos de animales actuales emparentados o muy afines. Sin embargo, en muchas colecciones osteológicas falta información sobre la talla corporal de los ejemplares, de forma que las investigaciones publicadas usualmente recurren a datos sintetizados de la literatura que se relacionan con medidas tomadas directamente del material esquelético. La utilidad de estas aproximaciones más allá de indicaciones generales sobre la talla es discutible. En un esfuerzo de minimizar estos problemas intentamos establecer bases objetivas para el uso de los elementos esqueléticos con el propósito de

  5. Assessment of cardiac blood pool imaging in patients with left ventricular outflow tract stenosis

    International Nuclear Information System (INIS)

    Nakamura, Yutaka; Ono, Yasuo; Kohata, Tohru; Tsubata, Shinichi; Kamiya, Tetsuroh.

    1993-01-01

    We performed cardiac blood pool imagings with Tc-99m at rest and during supine ergometer exercise to evaluate left ventricular performance in 14 patients with left ventricular outflow tract stenosis. All catheterized patients were divided into two subgroups: 8 patients with peak systolic left ventricular to descending aortic pressure gradients of less than 50 mmHg (LPG group) and 6 patients with peak systolic gradients of more than 50 mmHg (HPG group). Control group included 10 patients without stenotic coronary lesions after Kawasaki disease. Left ventricular ejection fraction (LVEF) was obtained as systolic index; both filling fraction during the first third of diastole (1/3FF) and mean filling rate during the first third of diastole (1/3FR mean) were obtained as diastolic indices. None of the patients had abnormal findings on 201 Tl imaging. LVEF at rest in HPG group was significantly higher than those in control group, but LVEF in HPG group did not increase after exercise. It increased significantly in control group and LPG group. 1/3 FF in HPG group was significantly lower not only at rest but also during exercise. 1/3 FR mean at rest was not different significantly among the 3 groups. However, 1/3FR mean during exercise in LPG group was significantly lower; and 1/3 FR mean during exercise was significantly lower in HPG group than LPG group. The ratio of left ventricular muscular mass to left ventricular end-diastolic volume (M/V) calculated from left ventricular cineangiograms was different significantly among the 3 groups. The M/V ratio showed a correlation with LVEF and 1/3 FF both at rest and during exercise. These results would indicate that systolic function was impaired on exercise in severe left ventricular outflow tract stenosis and diastolic function was impaired on exercise in mild and severe left ventricular outflow tract stenosis. This may correlate with left ventricular hypertrophy and interaction of systolic function. (author)

  6. Response of left ventricular volume to exercise in man assessed by radionuclide equilibrium angiography

    International Nuclear Information System (INIS)

    Slutsky, R.; Karliner, J.; Ricci, D.; Schuler, G.; Pfisterer, M.; Peterson, K.; Ashburn, W.

    1979-01-01

    To assess the effects of exercise on left ventricular volumes we studied 10 normal men, 15 patients with coronary disease who developed angina pectoris during exercise, and 10 patients with known coronary disease who did not develop angina during exercise. Each subject performed supine bicycle exercise under a mobile, single-crystal scintillation camera until angina or fatigue occurred. Technetium-99m bound to human serum albumin was the imaging agent. Data were collected at rest and during the last 2 minutes of each 3-minute stage of exercise and for 10 minutes after exercise. Volumes were calculated by a new radionuclide technique that correlated well with cineangiography and is expressed in nondimensional units. In normal subjects, the end-diastolic volume (EDV) at rest was not different from that a peak exercise. The end-systolic volume (ESV) decreased at peak exercise. ESV decreased progressively in all but two of 30 exercise periods. Angina patients had a larger EDV at rest and during chest pain than normals. Angina patients increased their ESV during chest pain resulting in a decreased ejection fraction (EF). All angina patients had a higher ESV during chest pain than during the exercise stage before chest pain. As a group, patients who did not develop angina had a lower EDV at rest and peak exercise than those who did develop angina. We conclude: that the EF increases during exercise due to a decrease in ESV; that the EF in patients with angina decreases because of an increase in ESV; and that the EF in coronary disease patients without angina shows no change because there is no significant change in the ESV. Radionuclide equilibrium angiography may prove useful for assessing EF and volume changes in patients with coronary artery disease

  7. "3D fusion" echocardiography improves 3D left ventricular assessment: comparison with 2D contrast echocardiography.

    Science.gov (United States)

    Augustine, Daniel; Yaqub, Mohammad; Szmigielski, Cezary; Lima, Eduardo; Petersen, Steffen E; Becher, Harald; Noble, J Alison; Leeson, Paul

    2015-02-01

    Three-dimensional fusion echocardiography (3DFE) is a novel postprocessing approach that utilizes imaging data acquired from multiple 3D acquisitions. We assessed image quality, endocardial border definition, and cardiac wall motion in patients using 3DFE compared to standard 3D images (3D) and results obtained with contrast echocardiography (2DC). Twenty-four patients (mean age 66.9 ± 13 years, 17 males, 7 females) undergoing 2DC had three, noncontrast, 3D apical volumes acquired at rest. Images were fused using an automated image fusion approach. Quality of the 3DFE was compared to both 3D and 2DC based on contrast-to-noise ratio (CNR) and endocardial border definition. We then compared clinical wall-motion score index (WMSI) calculated from 3DFE and 3D to those obtained from 2DC images. Fused 3D volumes had significantly improved CNR (8.92 ± 1.35 vs. 6.59 ± 1.19, P echocardiography (1.06 ± 0.09 vs. 1.07 ± 0.15, P = 0.69), whereas unfused images produced significantly more variable results (1.19 ± 0.30). This was confirmed by a better intraclass correlation coefficient (ICC 0.72; 95% CI 0.32-0.88) relative to comparisons with unfused images (ICC 0.56; 95% CI 0.02-0.81). 3DFE significantly improves left ventricular image quality compared to unfused 3D in a patient population and allows noncontrast assessment of wall motion that approaches that achieved with 2D contrast echocardiography. © 2014, Wiley Periodicals, Inc.

  8. Changes in right ventricular function assessed by echocardiography in dog models of mild RV pressure overload.

    Science.gov (United States)

    Morita, Tomoya; Nakamura, Kensuke; Osuga, Tatsuyuki; Yokoyama, Nozomu; Morishita, Keitaro; Sasaki, Noboru; Ohta, Hiroshi; Takiguchi, Mitsuyoshi

    2017-07-01

    The assessment of hemodynamic change by echocardiography is clinically useful in patients with pulmonary hypertension. Recently, mild elevation of the mean pulmonary arterial pressure (PAP) has been shown to be associated with increased mortality. However, changes in the echocardiographic indices of right ventricular (RV) function are still unknown. The objective of this study was to validate the relationship between echocardiographic indices of RV function and right heart catheterization variables under a mild RV pressure overload condition. Echocardiography and right heart catheterization were performed in dog models of mild RV pressure overload induced by thromboxane A 2 analog (U46619) (n=7). The mean PAP was mildly increased (19.3±1.1 mm Hg), and the cardiac index was decreased. Most echocardiographic indices of RV function were significantly impaired even under a mild RV pressure overload condition. Multivariate analysis revealed that the RV free wall longitudinal strain (RVLS), standard deviation of the time-to-peak longitudinal strain of RV six segments (RV-SD) by speckle-tracking echocardiography, and Tei index were independent echocardiographic predictors of the mean PAP (free wall RVLS, β=-0.60, P<.001; RV-SD, β=0.40, P=.011), pulmonary vascular resistance (free wall RVLS, β=-0.39, P=.020; RV-SD, β=0.47, P=.0086; Tei index, β=0.34, P=.047), and cardiac index (Tei index, β=-0.65, P<.001). Free wall RVLS, RV-SD, and Tei index are useful for assessing the hemodynamic change under a mild RV pressure overload condition. © 2017, Wiley Periodicals, Inc.

  9. Assessment of left ventricular function using dobutamine stress echocardiography and myocardial scintigraphy in valvular heart disease

    International Nuclear Information System (INIS)

    Ozaki, Nobuchika; Sugimoto, Takaki; Okada, Masayoshi

    1999-01-01

    To assess the left ventricular (LV) function in valvular heart disease, we employed the preoperative dobutamine stress echocardiography and the myocardial scintigraphy. During the past 13 years, 37 of 324 the patients showed LV dysfunction with the % fractional shortening (%FS) of 25% or less in the preoperative echocardiogram. These patients were retrospectively divided into two groups; Group A (n=21): %FS has improved late after operation; Group B (n=16): %FS has deteriorated or LV failure occurred. The mean follow-up period was 84±54 months after valve surgery. No significant differences were observed in the preoperative characteristics and operative variables between these two groups. The dobutamine stress test had been performed in 8 patients in Group A and 9 patients in Group B preoperatively, and the maximum increase ratio of %FS (Δ%FS) was used for assessment. Seven patients in Group A had showed Δ%FS of more than 9%, while all patients in Group B had showed Δ%FS of less than 9%. Myocardial scintigraphy was performed in 11 patients of them, and another 22 patients with %FS of above 25% acted as the control group. The Defect Score, which was defined as the sum of defect scales in 25 LV segments, showed a significant difference between 11 patients with LV dysfunction and control group. The distribution of the Defect Score in each myocardial segment, showed significantly higher in the posterior and inferior LV segments. In addition, the perfusion defect on myocardial imaging was initiated in the junction between the septal and LV free wall, and extended from the posterior to the lateral wall along with deterioration of LV function. In conclusion, preoperative dobutamine stress echocardiography proved to be very useful for prediction of the postoperative LV function, and myocardial scintigraphy might be indicative of LV function even in valvular heart disease. (author)

  10. Assessment of left ventricular function using dobutamine stress echocardiography and myocardial scintigraphy in valvular heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Ozaki, Nobuchika; Sugimoto, Takaki; Okada, Masayoshi [Kobe Univ. (Japan). School of Medicine

    1999-02-01

    To assess the left ventricular (LV) function in valvular heart disease, we employed the preoperative dobutamine stress echocardiography and the myocardial scintigraphy. During the past 13 years, 37 of 324 the patients showed LV dysfunction with the % fractional shortening (%FS) of 25% or less in the preoperative echocardiogram. These patients were retrospectively divided into two groups; Group A (n=21): %FS has improved late after operation; Group B (n=16): %FS has deteriorated or LV failure occurred. The mean follow-up period was 84{+-}54 months after valve surgery. No significant differences were observed in the preoperative characteristics and operative variables between these two groups. The dobutamine stress test had been performed in 8 patients in Group A and 9 patients in Group B preoperatively, and the maximum increase ratio of %FS ({delta}%FS) was used for assessment. Seven patients in Group A had showed {delta}%FS of more than 9%, while all patients in Group B had showed {delta}%FS of less than 9%. Myocardial scintigraphy was performed in 11 patients of them, and another 22 patients with %FS of above 25% acted as the control group. The Defect Score, which was defined as the sum of defect scales in 25 LV segments, showed a significant difference between 11 patients with LV dysfunction and control group. The distribution of the Defect Score in each myocardial segment, showed significantly higher in the posterior and inferior LV segments. In addition, the perfusion defect on myocardial imaging was initiated in the junction between the septal and LV free wall, and extended from the posterior to the lateral wall along with deterioration of LV function. In conclusion, preoperative dobutamine stress echocardiography proved to be very useful for prediction of the postoperative LV function, and myocardial scintigraphy might be indicative of LV function even in valvular heart disease. (author)

  11. Single-photon emission computed tomography for the assessment of ventricular perfusion and function

    International Nuclear Information System (INIS)

    Gonzalez, Patricio; Dussaillant, Gaston; Gutierrez, Daniela; Berrocal, Isabel; Alay, Rita; Otarola, Sonia

    2013-01-01

    Background: Single-photon emission computed tomography (SPECT) can be used as a non-invasive tool for the assessment of coronary perfusion. Aim: To assess ventricular perfusion and function by SPECT in patients with single vessel coronary artery disease. Material and Methods: Among patients with indications for a coronary artery angiography, those with significant lesions in one vessel, were selected for the study. Within 24 hours, cardiac SPECT examinations on basal conditions and after high doses of dipyridamole, were performed. SPECT data from 38 patients with a low probability of coronary artery disease was used for comparisons. Results:Ten patients aged 61 ± 8 years (seven men) were studied. Visual analysis of SPECT revealed signs suggestive of ischemia in eight patients. The remaining two patients did not have perfusion disturbances. SPECT detected eight of ten abnormal vessels reported in the coronary artery angiography. There were two false negative results Summed stress, summed rest and summed difference scores were 9.78 ± 6.51, 3.22 ± 5.07 and 6.33 ± 4.97, respectively. The ejection fractions under stress and at rest were 53 ± 11.7% and 61 ± 15.7% respectively (p ≤ 0.01). The figures for the control group were 69.1 ± 13.5% and 75.2 ± 12.04% respectively (significantly different from patients). Two patients had a summed motion score above 14.9. Likewise, two patients had a summed thickening score above 10.9. Conclusions: SPECT detected 80% of coronary lesions found during coronary artery angiography. Visual analysis of perfusion is highly reliable for diagnosis. Quantitative parameters must be considered only as reference parameters

  12. The Prognostic Value of Left Atrial Peak Reservoir Strain in Acute Myocardial Infarction Is Dependent on Left Ventricular Longitudinal Function and Left Atrial Size

    DEFF Research Database (Denmark)

    Ersbøll, Mads; Andersen, Mads J; Valeur, Nana

    2013-01-01

    of PALS and left ventricular longitudinal strain (global longitudinal strain) in large-scale populations in regard to prognosis. METHODS AND RESULTS: We prospectively included 843 patients (mean age 62.1+/-11.8; 74% male) with acute myocardial infarction and measured global longitudinal strain, left......BACKGROUND: Peak atrial longitudinal strain (PALS) during the reservoir phase has been proposed as a measure of left atrium function in a range of cardiac conditions, with the potential for added pathophysiological insight and prognostic value. However, no studies have assessed the interrelation...

  13. Detection of infarct size safety threshold for left ventricular ejection fraction impairment in acute myocardial infarction successfully treated with primary percutaneous coronary intervention.

    Science.gov (United States)

    Sciagrà, Roberto; Cipollini, Fabrizio; Berti, Valentina; Migliorini, Angela; Antoniucci, David; Pupi, Alberto

    2013-04-01

    In acute myocardial infarction (AMI) treated by primary percutaneous coronary intervention (PCI), there is a direct relationship between myocardial damage and consequent left ventricular (LV) functional impairment. It is however unclear whether there is a safety threshold below which infarct size does not significantly affect LV ejection fraction (EF). The aim of this study was to evaluate the relationship between infarct size and LVEF in AMI patients treated by successful PCI using a specific statistical approach to identify a possible safety threshold. Among patients with recent AMI submitted to perfusion gated single photon emission computed tomography (SPECT) to define the infarct size, the data of 427 subjects with sizable infarct size were considered. The relationship between infarct size and LVEF was analysed using a simple segmented regression (SSR) model and an iterative algorithm based on robust least squares (RLS) for parameter estimation. The RLS algorithm detected two break points in the SSR model, set at infarct size values of 11.0 and 51.5 %. Because the slope coefficients of the two extreme segments of the regression line were not significant, by constraining such segments to zero slope in the SSR model, the lower break point was identified at infarct size = 8 % and the upper one at 45 %. Using a rigorous statistical approach, it is possible to demonstrate that below a threshold of 8 % the infarct size apparently does not affect the LVEF and therefore a safety threshold could be set at this value. Furthermore, the same analysis suggests that the relationship between infarct size and LVEF impairment is lost for an infarct size > 45 %.

  14. Genome-wide assessment for genetic variants associated with ventricular dysfunction after primary coronary artery bypass graft surgery.

    Directory of Open Access Journals (Sweden)

    Amanda A Fox

    Full Text Available BACKGROUND: Postoperative ventricular dysfunction (VnD occurs in 9-20% of coronary artery bypass graft (CABG surgical patients and is associated with increased postoperative morbidity and mortality. Understanding genetic causes of postoperative VnD should enhance patient risk stratification and improve treatment and prevention strategies. We aimed to determine if genetic variants associate with occurrence of in-hospital VnD after CABG surgery. METHODS: A genome-wide association study identified single nucleotide polymorphisms (SNPs associated with postoperative VnD in male subjects of European ancestry undergoing isolated primary CABG surgery with cardiopulmonary bypass. VnD was defined as the need for ≥2 inotropes or mechanical ventricular support after CABG surgery. Validated SNPs were assessed further in two replication CABG cohorts and meta-analysis was performed. RESULTS: Over 100 SNPs were associated with VnD (P2.1 of developing in-hospital VnD after CABG surgery. However, three genetic loci identified by meta-analysis were more modestly associated with development of postoperative VnD. Studies of larger cohorts to assess these loci as well as to define other genetic mechanisms and related biology that link genetic variants to postoperative ventricular dysfunction are warranted.

  15. Angiotensin infusion effects on left ventricular function. Assessment in normal subjects and in patients with coronary disease.

    Science.gov (United States)

    Bianco, J A; Laskey, W K; Makey, D G; Shafer, R B

    1980-02-01

    Radionuclide multigating of the cardiac cycle was employed to assess effects of angiotensin infusion on left ventricular function. In six normal subjects, angiotensin infusion decreased heart rate (HR) from 72 +/- SEM 2 to 57 +/- 2 beats/min (P less than 0.001); while systolic blood pressure (BP) increased from 119 +/- 2 to 178 +/- 1 mm Hg (P less than 0.001), and ejection fraction (EF) declined from 58 +/- 1 to 47 +/- 2 percent (P less than 0.05). In contrast, in 11 normal subjects, supine exercise increased HR and systolic BP by 55 and 49 percent, whereas EF increased from 64 +/- 1 to 71 +/- 1 (P less than 0.001). In ten patients with CAD, angiotensin infusion produced no change in HR, increased systolic BP by 34 percent, and decreased EF by 11 percent. Angiotensin infusion induced left ventricular depression in normal subjects and in patients with CAD. It cannot substitute for exercise in intervention radionuclide ventriculography.

  16. Assessment of left ventricular wall motion and function by cross-sectional echocardiography

    International Nuclear Information System (INIS)

    Ono, Akifumi; Hirata, Shunkichi; Ishikawa, Kyozo

    1982-01-01

    The clinical efficacy of cross-sectional echocardiography (CSE) was evaluated with M-mode echocardiography and radionuclide cardioangiography (RCG) in 50 cases including 30 patients with myocardial infarction. Segmental wall motion by CSE was highly correlated with segmental wall motion and left ventricular ejection fraction by RCG (r = 0.89 in the former, r = -0.84 in the latter). On the other hand, the left ventricular ejection fraction by M-mode echocardiography revealed a fairly well correlation with that by RCG ( r = 0.68). These results suggest that, as compared with RCG, CSE is quite useful in an evaluation of left ventricular function and in a detection of segmental wall motion abnormalities. (author)

  17. Echocardiographic assessment of fetal left ventricular function in hypertensive disorder of pregnancy

    International Nuclear Information System (INIS)

    Liu Xiaozhen; Liu Shaozhong

    2011-01-01

    Objective: To investigate fetal left ventricular function in hypertensive disorder of pregnancy (HDP). Methods: Fetuses of hypertensive (84) and normotensive (147) mothers were enrolled in this study. The fetal left ventricular ejection fractions, E/A ratios of mitral valves, left atrial shortening fractions and Tei indexes of the two groups were measured on fetal echocardiography. Results: The left ventricular ejection fractions (P=0.040), E/A ratios of the mitral valves (P=0.042) and the left atrial shortening fractions (P=0.036) in fetuses of HDP were significantly smaller than those of the normal group whereas the Tei indexes (P=0.030) were significantly larger than those of the normal group. Conclusion: The hypertensive disorder of pregnancy may cause decreased systolic, diastolic and global function of the fetal left ventricle. (authors)

  18. Assessing learning in small sized physics courses

    Directory of Open Access Journals (Sweden)

    Emanuela Ene

    2018-01-01

    Full Text Available We describe the construction, validation, and testing of a concept inventory for an Introduction to Physics of Semiconductors course offered by the department of physics to undergraduate engineering students. By design, this inventory addresses both content knowledge and the ability to interpret content via different cognitive processes outlined in Bloom’s revised taxonomy. The primary challenge comes from the low number of test takers. We describe the Rasch modeling analysis for this concept inventory, and the results of the calibration on a small sample size, with the intention of providing a useful blueprint to other instructors. Our study involved 101 students from Oklahoma State University and fourteen faculty teaching or doing research in the field of semiconductors at seven universities. The items were written in four-option multiple-choice format. It was possible to calibrate a 30-item unidimensional scale precisely enough to characterize the student population enrolled each semester and, therefore, to allow the tailoring of the learning activities of each class. We show that this scale can be employed as an item bank from which instructors could extract short testlets and where we can add new items fitting the existing calibration.

  19. Assessing learning in small sized physics courses

    Science.gov (United States)

    Ene, Emanuela; Ackerson, Bruce J.

    2018-01-01

    We describe the construction, validation, and testing of a concept inventory for an Introduction to Physics of Semiconductors course offered by the department of physics to undergraduate engineering students. By design, this inventory addresses both content knowledge and the ability to interpret content via different cognitive processes outlined in Bloom's revised taxonomy. The primary challenge comes from the low number of test takers. We describe the Rasch modeling analysis for this concept inventory, and the results of the calibration on a small sample size, with the intention of providing a useful blueprint to other instructors. Our study involved 101 students from Oklahoma State University and fourteen faculty teaching or doing research in the field of semiconductors at seven universities. The items were written in four-option multiple-choice format. It was possible to calibrate a 30-item unidimensional scale precisely enough to characterize the student population enrolled each semester and, therefore, to allow the tailoring of the learning activities of each class. We show that this scale can be employed as an item bank from which instructors could extract short testlets and where we can add new items fitting the existing calibration.

  20. Serial Noninvasive Assessment of Apoptosis During Right Ventricular Disease Progression in Rats

    NARCIS (Netherlands)

    Campian, Maria E.; Verberne, Hein J.; Hardziyenka, Maxim; de Bruin, Kora; Selwaness, Mariana; van den Hoff, Maurice J. B.; Ruijter, Jan M.; van Eck-Smit, Berthe L. F.; de Bakker, Jacques M. T.; Tan, Hanno L.

    2009-01-01

    Right ventricular (RV) function is the major determinant of survival in patients with pulmonary hypertension. Yet, the pathophysiologic basis of RV disease is unresolved. We aimed to study the role of apoptosis in RV disease by monitoring it serially during disease progression using in vivo

  1. Pathophysiologic assessment of left ventricular hypertrophy and strain in asymptomatic patients with essential hypertension

    International Nuclear Information System (INIS)

    Pringle, S.D.; Macfarlane, P.W.; McKillop, J.H.; Lorimer, A.R.; Dunn, F.G.

    1989-01-01

    To investigate the significance of the electrocardiographic (ECG) pattern of left ventricular hypertrophy and strain, two groups of asymptomatic patients with essential hypertension were compared. The patients were similar in terms of age, smoking habit, serum cholesterol and blood pressure levels, but differed in the presence (Group I, n = 23) or absence (Group II, n = 23) of the ECG pattern of left ventricular hypertrophy and strain. Group I patients had significantly more episodes of exercise-induced ST segment depression (14 versus 4, p less than 0.05) and reversible thallium perfusion abnormalities (11 of 23 versus 3 of 23, p less than 0.05) despite similar exercise capacity and absence of chest pain. Nonsustained ventricular tachycardia was detected on 24 h ambulatory ECG monitoring in two patients in Group I, but no patient in Group II. Coronary arteriography performed in 20 Group I patients demonstrated significant coronary artery disease in 8 patients. This study has shown that there is a subgroup of hypertensive patients with ECG left ventricular hypertrophy and strain who have covert coronary artery disease. This can be detected by thallium perfusion scintigraphy, and may contribute to the increased risk known to be associated with this ECG abnormality

  2. Assessment of subclinical right ventricular systolic dysfunction in coal miners using myocardial isovolumic acceleration.

    Science.gov (United States)

    Ozcan Abacıoglu, Ozge; Kaplan, Mehmet; Abacıoglu, Serkan; Quisi, Ala

    2017-09-01

    Several studies have been conducted regarding the effects of coal mining on the respiratory system. However, there is a lack of data concerning potential effects of coal mining on the cardiovascular system. In this study, we aimed to evaluate the potential subclinical right and left ventricular dysfunction in coal miners. This single-center, prospective study included a total of 102 patients. Patient and control groups consisted of 54 coal miners and 48 healthy men, respectively. All patients underwent 12-lead electrocardiography, transthoracic echocardiography, and pulmonary function test. As compared to control group, coal miners had significantly higher right ventricular myocardial performance index (RVMPI) (0.41 ± 0.03 vs 0.37 ± 0.02, P right ventricular fractional area change (RVFAC) (33.55% ± 6.70% vs 37.04 ± 9.26 P right and left ventricular dysfunction, including RVMPI, RVFAC, TAPSE, IVA, and AD, are impaired in coal miners. © 2017 The Authors Echocardiography Published by Wiley Periodicals, Inc.

  3. Accuracy of endoscopic intraoperative assessment of urologic stone size.

    Science.gov (United States)

    Patel, Nishant; Chew, Ben; Knudsen, Bodo; Lipkin, Michael; Wenzler, David; Sur, Roger L

    2014-05-01

    Endoscopic treatment of renal calculi relies on surgeon assessment of residual stone fragment size for either basket removal or for the passage of fragments postoperatively. We therefore sought to determine the accuracy of endoscopic assessment of renal calculi size. Between January and May 2013, five board-certified endourologists participated in an ex vivo artificial endoscopic simulation. A total of 10 stones (pebbles) were measured (mm) by nonparticipating urologist (N.D.P.) with electronic calibers and placed into separate labeled opaque test tubes to prevent visualization of the stones through the side of the tube. Endourologists were blinded to the actual size of the stones. A flexible digital ureteroscope with a 200-μm core sized laser fiber in the working channel as a size reference was placed through the ureteroscope into the test tube to estimate the stone size (mm). Accuracy was determined by obtaining the correlation coefficient (r) and constructing an Altman-Bland plot. Endourologists tended to overestimate actual stone size by a margin of 0.05 mm. The Pearson correlation coefficient was r=0.924, with a p-valuestones (stones (≥4 mm), r=0.911 vs r=0.666. Altman-bland plot analysis suggests that surgeons are able to accurately estimate stone size within a range of -1.8 to +1.9 mm. This ex vivo simulation study demonstrates that endoscopic assessment is reliable when assessing stone size. On average, there was a slight tendency to overestimate stone size by 0.05 mm. Most endourologists could visually estimate stone size within 2 mm of the actual size. These findings could be generalized to state that endourologists are accurately able to intraoperatively assess residual stone fragment size to guide decision making.

  4. Longitudinal Assessment of Left Ventricular Mass in Autosomal Dominant Polycystic Kidney Disease

    Directory of Open Access Journals (Sweden)

    Taimur Dad

    2018-05-01

    Full Text Available Introduction: The high burden of cardiovascular morbidity and mortality in autosomal dominant polycystic kidney disease (ADPKD is related to development of hypertension and left ventricular hypertrophy. Blood pressure reduction has been shown to reduce left ventricular mass in ADPKD; however, moderators and predictors of response to lower blood pressure are unknown. Methods: This was a post hoc cohort analysis of HALT PKD study A, a randomized placebo controlled trial examining the effect of low blood pressure and single versus dual renin−angiotensin blockade in early ADPKD. Participants were hypertensive ADPKD patients 15 to 49 years of age with estimated glomerular filtration rate (eGFR > 60 ml/min per 1.73 m2 across 7 centers in the United States. Predictors included age, sex, baseline eGFR, systolic blood pressure, total kidney volume, serum potassium, and urine sodium, potassium, albumin, and aldosterone. Outcome was left ventricular mass index (LVMI measured using 1.5-T magnetic resonance imaging at months 0, 24, 48, and 60. Results: Reduction in LVMI was associated with higher baseline systolic blood pressure and larger kidney volume regardless of blood pressure control group assignment (P < 0.001 for both. Male sex and baseline eGFR were associated with a positive annual slope in LVMI (P < 0.001 and P = 0.07, respectively. Conclusion: Characteristics associated with higher risk of progression in ADPKD, including higher systolic blood pressure, larger kidney volume, and lower eGFR are associated with improvement in LVMI with intensive blood pressure control, whereas male sex is associated with a smaller slope of reduction in LVMI. Keywords: autosomal dominant polycystic kidney disease, hypertension, left ventricular hypertrophy, left ventricular mass index

  5. Effect of recombinant tissue-type plasminogen activator on acute myocardial infarction; Limitation of infarct size and preservation of left ventricular function evaluated by radionuclide methods

    Energy Technology Data Exchange (ETDEWEB)

    Fukuyama, Takaya; Inou, Tetsuji; Ashihara, Toshiaki; Ogata, Ikuo; Nabeyama, Shouzou; Yamada, Akira; Murakami, Satoshi; Kodama, Mayuko; Matsui, Kanji (Matsuyama Red Cross Hospital, Ehime (Japan))

    1989-12-01

    Radionuclide studies were performed in 18 patients with acute myocardial infarction receiving i.v. injection of recombinant tissue-type plasminogen activator (rt-PA) within 12 hr after an attack. Thallium-201 single photon emission computed tomography revealed that infarct size decreased by 42% in the rt-PA treated group, as compared with 25% in the control group. Left ventricular ejection fraction, as found on first-pass radionuclide angiography with Tc-99m PYP, was significantly higher in the rt-PA treated group than the control group (49% vs 38%). Radionuclide imagings were helpful in confirming myocardial salvage after rt-PA intravenous therapy. It was also considered necessary to perform rt-PA therapy as early as possible after an acute myocardial attack. (N.K.).

  6. Assessment of regional left ventricular function by Dual Source Computed Tomography: Interobserver variability and validation to laevocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Pflederer, T. [Department of Internal Medicine 2 (Cardiology), University of Erlangen (Germany)], E-mail: tobiaspflederer@web.de; Ho, K.T. [Department of Cardiology, Tan Tock Seng Hospital (Singapore)], E-mail: contact@ttsh.com.sg; Anger, T. [Department of Internal Medicine 2 (Cardiology), University of Erlangen (Germany)], E-mail: thomas.anger@uk-erlangen.de; Kraehner, R. [Department of Internal Medicine 2 (Cardiology), University of Erlangen (Germany)], E-mail: robert.kraehner@uk-erlangen.de; Ropers, D. [Department of Internal Medicine 2 (Cardiology), University of Erlangen (Germany)], E-mail: dieter.ropers@uk-erlangen.de; Muschiol, G. [Department of Internal Medicine 2 (Cardiology), University of Erlangen (Germany)], E-mail: gerd.muschiol@uk-erlangen.de; Renz, A. [Department of Internal Medicine 2 (Cardiology), University of Erlangen (Germany)], E-mail: alexandra.renz@uk-erlangen.de; Daniel, W.G. [Department of Internal Medicine 2 (Cardiology), University of Erlangen (Germany)], E-mail: werner.daniel@uk-erlangen.de; Achenbach, S. [Department of Internal Medicine 2 (Cardiology), University of Erlangen (Germany)], E-mail: stephan.achenbach@uk-erlangen.de

    2009-10-15

    Objective: Assessment of left ventricular function is possible in contrast-enhanced cardiac CT data sets. However, rapid ventricular motion especially in systole can lead to artifacts. Dual Source Computed Tomography (DSCT) has high temporal resolution which effectively limits motion artifact. We therefore assessed the accuracy of DSCT to detect regional left ventricular wall motion abnormalities in comparison to invasive cine angiocardiography. Methods: We analyzed DSCT data sets of 50 patients (39 male, 11 female, mean age: 61 {+-} 10 years) which were acquired after intravenous injection of 55-70 mL contrast agent (rotation time: 330 ms, collimation: 2 mm x 64 mm x 0.6 mm, 120 kV, 380 mAs, ECG-correlated tube current modulation). 10 data sets consisting of transaxial slices with a slice thickness of 1.5 mm, an increment of 1.0 mm and a matrix of 256 x 256 pixels were reconstructed at 10 time instants during the cardiac cycle (0-90% in 10% increments). The data sets were analyzed visually by two independent readers, using standard left ventricular planes, concerning regional wall motion abnormalities. DSCT was verified in a blinded fashion against cine ventriculography performed during cardiac catheterization (RAO and LAO projection), using a 7-segment model. Analysis was performed on a per-patient (presence of at least one hypo-, a- or dyskinetic segment) and on a per-segment basis. Results: Concerning the presence of a wall motion abnormality, the two observers agreed in 340/350 segments (97%) and 48/50 patients (96%). In invasive cine angiocardiography, 22 of 50 patients displayed at least one segment with abnormal contraction. To detect these patients, DSCT showed a sensitivity of 95% (21/22), specificity of 96% (27/28), positive predictive value of 95% and negative predictive value of 96%. Out of a total of 350 left ventricular segments, 66 segments had abnormal contraction in cine angiocardiography (34 hypokinetic, 26 akinetic, 6 dyskinetic). For detection

  7. Assessment of relationship between regional perfusion and ventricular function in patients with severely depressed ejection fraction

    International Nuclear Information System (INIS)

    Teresinska, A.; Konieczna, S.; Szumilak, B.; Gosiewska-Marcinkowska, E.; Potocka, J.

    1998-01-01

    Patients with low ventricular (LV) ejection fraction (EF) and with regional or global LV dysfunction, considered for myocardial revascularization, are often submitted to myocardial perfusion study to ptrove perfusion preserved and to approximate viability. The aim of this work is to evaluate, to what extent SPECT with Tc-99m-MIBI (SPECT-MIBI) additionally differentiatesa and enlarges the information on LV contractility achieved from radioisotopic ventriculography (RNV). Seventy-three patients with EF=0.11-0.35 (mean: 0.26 ± 0.06, calculated from RNV) were studied. Planar gated RNV and SPECT-MIBI were performed within 2 months (mean: 15 ± 14 days). RNV, after in vivo red cells labeling with Tc-99m, was recorded in rest in LAO45 and RAO30 views. Global EF and contractility of 5 regions (anterior, posterior, lateral walls, septum and apex) were evaluated. Assessment was performed by means of LV in 'cine' mode,m ED and ES outlines and amplitude-phase images. Regional contractility abnormalities were classified as dyskinesis, akinesis and hypokinesis. SPECT-MIBI was performed in rest and stress. Perfusion abnormalities in 5 above mentioned regions was classified as large (more intense than 50% of myocardial maximum) or small persistent defects (DEFpers), large or small partially reversible defects (DEFpart-rev), large or small completely reversible defects (DEFrev). Hypokinesis was detected in 23-35 regions (65%) , dyskinesis - in 63 (17%), akinesis - in 37 (10%), normokinesis - in 27 (7%). In dyskinetic regions, there existed large DEFpers (79%) or large DEFpart-rev (21%). In akinetic regions, there also existed large DEFpers (68%) or large DEFpart-rev (32%). In hypokinetic regions, there were no perfusion defects (31% of regions), small DEFpers, DEFrev and DEFpart-rev (42%) and also large DEFpers (27%). In most of normokinetic regions, different types of perfusion defects were observed (large DEFpers existed in 26% of regions). In summary: In dyskinetic and akinetic

  8. Echocardiographic evaluation of changes in left ventricular size and valvular regurgitation associated with physical training during and after maturity in standardbred trotters

    DEFF Research Database (Denmark)

    Buhl, Rikke; Ersbøll, Annette Kjær

    2012-01-01

    To assess whether physical training induces cardiac hypertrophy and valvular regurgitation in maturing Standardbred trotters and to establish a prediction model for the size of the left ventricle.......To assess whether physical training induces cardiac hypertrophy and valvular regurgitation in maturing Standardbred trotters and to establish a prediction model for the size of the left ventricle....

  9. Kidney size in infants and children assessed by area measurement

    International Nuclear Information System (INIS)

    Jorulf, H.; Nordmark, J.; Jonsson, A.

    1978-01-01

    A method for assessment of the kidney size in infants and children is described based on measurement of the renal parenchymal area determined planimetrically, using for reference the height of the column of the upper three lumbar vertebrae or the body weight. The kidney size is expressed in standard deviation in the appropriate nomograms. (Auth.)

  10. Age-related normal structural and functional ventricular values in cardiac function assessed by magnetic resonance

    International Nuclear Information System (INIS)

    Fiechter, Michael; Gaemperli, Oliver; Kaufmann, Philipp A; Fuchs, Tobias A; Gebhard, Catherine; Stehli, Julia; Klaeser, Bernd; Stähli, Barbara E; Manka, Robert; Manes, Costantina; Tanner, Felix C

    2013-01-01

    The heart is subject to structural and functional changes with advancing age. However, the magnitude of cardiac age-dependent transformation has not been conclusively elucidated. This retrospective cardiac magnetic resonance (CMR) study included 183 subjects with normal structural and functional ventricular values. End systolic volume (ESV), end diastolic volume (EDV), and ejection fraction (EF) were obtained from the left and the right ventricle in breath-hold cine CMR. Patients were classified into four age groups (20–29, 30–49, 50–69, and ≥70 years) and cardiac measurements were compared using Pearson’s rank correlation over the four different groups. With advanced age a slight but significant decrease in ESV (r=−0.41 for both ventricles, P<0.001) and EDV (r=−0.39 for left ventricle, r=−0.35 for right ventricle, P<0.001) were observed associated with a significant increase in left (r=0.28, P<0.001) and right (r=0.27, P<0.01) ventricular EF reaching a maximal increase in EF of +8.4% (P<0.001) for the left and +6.1% (P<0.01) for the right ventricle in the oldest compared to the youngest patient group. Left ventricular myocardial mass significantly decreased over the four different age groups (P<0.05). The aging process is associated with significant changes in left and right ventricular EF, ESV and EDV in subjects with no cardiac functional and structural abnormalities. These findings underline the importance of using age adapted values as standard of reference when evaluating CMR studies

  11. Assessment of the background count to measure the left ventricular ejection fraction with a nuclear stethoscope

    International Nuclear Information System (INIS)

    Doi, Mayumi; Hiroe, Michiaki; Marumo, Fumiaki; Itoh, Haruki; Taniguchi, Koichi.

    1993-01-01

    The nuclear stethoscope is a newly developed device for monitoring left ventricular ejection fraction (EF) with a pair of cadmium telluride detector for both left ventricular count (first channel) and background count (second channel). Although it is useful for evaluating the cardiac function during exercise, the methodology of the calculation for distinguishing the net ventricular blood count from the background count has not been established yet. In order to establish a reasonable method to calculate EF, we measured EF using a nuclear stethoscope and conventional gated blood pool scintigraphy in 20 healthy volunteers. All subjects underwent two supine ergometer exercise tests consisting of the 3 stages for the nuclear stethoscope and blood pool scintigraphy. The EF was determined with the following three methods for the nuclear stethoscope: 1) Cut-off level was fixed at 70% of first channel, 2) Cut-off level at 75%, and 3) Cut-off level was determined by the background count obtained from second channel. There was a poor relationship between the EFs obtained from gated blood scintigraphy and the EFs from the nuclear stethoscope calculated by any of these methods. Regarding the EF calculated using the background count, however, the delta values of EF between rest and any of the 3 stages during exercise correlated closely to those EF from blood scintigraphy. When we apply the EF-at-rest value obtained from blood pool scintigraphy to analysis with the nuclear stethoscope, the EFs of 3 stages indicated good correlation (Stage I r=0.91, Stage II r=0.82, Stage III r=0.69). These results suggest that detecting the background count is useful in order to measure the left ventricular EF with the nuclear stethoscope. Since the absolute value of EF does not necessarily correlate to that from blood pool scintigraphy in this mehod, it is recommended to evaluate only the changing values of the EF. (author)

  12. Assessment of the background count to measure the left ventricular ejection fraction with a nuclear stethoscope

    Energy Technology Data Exchange (ETDEWEB)

    Doi, Mayumi; Hiroe, Michiaki; Marumo, Fumiaki (Tokyo Medical and Dental Univ. (Japan). School of Medicine); Itoh, Haruki; Taniguchi, Koichi

    1993-06-01

    The nuclear stethoscope is a newly developed device for monitoring left ventricular ejection fraction (EF) with a pair of cadmium telluride detector for both left ventricular count (first channel) and background count (second channel). Although it is useful for evaluating the cardiac function during exercise, the methodology of the calculation for distinguishing the net ventricular blood count from the background count has not been established yet. In order to establish a reasonable method to calculate EF, we measured EF using a nuclear stethoscope and conventional gated blood pool scintigraphy in 20 healthy volunteers. All subjects underwent two supine ergometer exercise tests consisting of the 3 stages for the nuclear stethoscope and blood pool scintigraphy. The EF was determined with the following three methods for the nuclear stethoscope: (1) Cut-off level was fixed at 70% of first channel, (2) Cut-off level at 75%, and (3) Cut-off level was determined by the background count obtained from second channel. There was a poor relationship between the EFs obtained from gated blood scintigraphy and the EFs from the nuclear stethoscope calculated by any of these methods. Regarding the EF calculated using the background count, however, the delta values of EF between rest and any of the 3 stages during exercise correlated closely to those EF from blood scintigraphy. When we apply the EF-at-rest value obtained from blood pool scintigraphy to analysis with the nuclear stethoscope, the EFs of 3 stages indicated good correlation (Stage I r=0.91, Stage II r=0.82, Stage III r=0.69). These results suggest that detecting the background count is useful in order to measure the left ventricular EF with the nuclear stethoscope. Since the absolute value of EF does not necessarily correlate to that from blood pool scintigraphy in this mehod, it is recommended to evaluate only the changing values of the EF. (author).

  13. Assessment of left ventricular function by thallium-201 quantitative gated cardiac SPECT

    International Nuclear Information System (INIS)

    Baba, Akira; Hano, Takuzo; Ohmori, Hisashi; Ibata, Masayo; Kawabe, Tetsuya; Kubo, Takashi; Kimura, Keizo; Nishio, Ichiro

    2002-01-01

    Present study was designed to evaluate the accuracy of the measurement of left ventricular volume by quantitative gated SPECT (QGS) software using 201 Tl and the effect of cutoff frequency of Butterworth prereconstruction filter on the calculation of volume. The RH-2 type cardiac phantom and 20 patients with ischemic heart disease were studied. Left ventricular end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were calculated by the QGS software using the various frequency of Butterworth filter. These parameters were evaluated by Simpson's method using left ventriculography (LVG). The volume of the phantom calculated by QGS was under-estimated by 14%. In the clinical study, EDV and ESV measured by QGS were smaller than those obtained from LVG by 10%. When the cutoff frequency of Butterworth filter was 0.43 cycles/cm, the values measured by QGS were best correlated with those by LVG (EDV: r=0.80, p 201 Tl quantitative gated cardiac SPECT can estimate myocardial ischemia and left ventricular function simultaneously. (author)

  14. Assessment of left ventricular function by thallium-201 quantitative gated cardiac SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Baba, Akira; Hano, Takuzo; Ohmori, Hisashi; Ibata, Masayo; Kawabe, Tetsuya; Kubo, Takashi; Kimura, Keizo; Nishio, Ichiro [Wakayama Medical Coll. (Japan)

    2002-02-01

    Present study was designed to evaluate the accuracy of the measurement of left ventricular volume by quantitative gated SPECT (QGS) software using {sup 201}Tl and the effect of cutoff frequency of Butterworth prereconstruction filter on the calculation of volume. The RH-2 type cardiac phantom and 20 patients with ischemic heart disease were studied. Left ventricular end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were calculated by the QGS software using the various frequency of Butterworth filter. These parameters were evaluated by Simpson's method using left ventriculography (LVG). The volume of the phantom calculated by QGS was under-estimated by 14%. In the clinical study, EDV and ESV measured by QGS were smaller than those obtained from LVG by 10%. When the cutoff frequency of Butterworth filter was 0.43 cycles/cm, the values measured by QGS were best correlated with those by LVG (EDV: r=0.80, p<0.001; ESV: r=0.86, p<0.001; EF: r=0.80, p<0.001). These data suggest that {sup 201}Tl quantitative gated cardiac SPECT can estimate myocardial ischemia and left ventricular function simultaneously. (author)

  15. Measurement of ventricular function using Doppler ultrasound

    International Nuclear Information System (INIS)

    Teague, S.M.

    1986-01-01

    Doppler has wide application in the evaluation of valvular heart disease. The need to know ventricular function is a much more common reason for an echocardiographic evaluation. Interestingly, Doppler examinations can assess ventricular function from many perspectives. Description of ventricular function entails measurement of the timing, rate and volume of ventricular filling and ejection. Doppler ultrasound examination reveals all of these aspects of ventricular function noninvasively, simply, and without great expense or radiation exposure, as described in this chapter

  16. Identification and Assessment of Paradoxical Ventricular Wall Motion Using ECG Gated Blood Pool Scan - Comparison of cine Loop , Phase Analysis and Paradox Image -

    International Nuclear Information System (INIS)

    Lee, Jae Tae; Kim, Gwang Weon; Lee, Kyu Bo; Chung, Byung Chun; Whang, Kee Suk; Chae, Sung Chul; Paek, Wee Hyun; Cheon, Jae Eun; Lee, Hyong Woo; Chung, Jin Hong

    1990-01-01

    Sixty-four patients with paradoxical ventricular wall motion noticed both in angiocardiography or 2-dimensional echocardiography were assessed by ECG gated blood pool scan (GBPS). Endless cine loop image, phase and amplitude images and paradox image obtained by visual inspection of each cardiac beat or Fourier transformation of acquired raw data were investigated to determine the incremental value of GBPS with these processing methods for identification of paradoxical ventricular wall motion. The results were as follows:1) Paradoxical wall motions were observed on interventricular septum in 34 cases, left ventricular free wall in 26 and right ventricular wall in 24. Underlying heart diseases were is chemic (23 cases) valvular(9), congenital heart disease (12), cardiomyopathy (5), pericardial effusion(5), post cardiac surgery(3), corpulmonale (2), endocarditis (l) and right ventricular tumor(l). 2) Left ventricular ejection fractions of patients with paradoxical left ventricular wall motion were significantly lower than those with paradoxical septal motion (p <0.005). 3) The sensitivity of each processing methods for detecting paradoxical wall motion was 76.9% by phase analysis, 74.6% by endless cine loop mapping and 68.4% by paradox image manipulation respectively. Paradoxial motions visualized only in phase, paradox or both images were appeared as hypokinesia or akinesia in cine loop image. 4) All events could be identified by at least one of above three processing methods, however only 34 cases (48.4%) showed the paradoxical motions in all of the three images. By these findings, we concluded that simultaneous inspection of all above three processing methods-endless cine loop, phase analysis and paradox image is necessary for accurate identification and assessment of paradoxical ventricular wall motion when performing GBPS.

  17. Identification and Assessment of Paradoxical Ventricular Wall Motion Using ECG Gated Blood Pool Scan - Comparison of cine Loop , Phase Analysis and Paradox Image -

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Tae; Kim, Gwang Weon; Lee, Kyu Bo; Chung, Byung Chun; Whang, Kee Suk; Chae, Sung Chul; Paek, Wee Hyun; Cheon, Jae Eun [Kyungpook National University School of Medicine, Daegu (Korea, Republic of); Lee, Hyong Woo; Chung, Jin Hong [Yeongnam National University College of Medicine, Daegu (Korea, Republic of)

    1990-07-15

    Sixty-four patients with paradoxical ventricular wall motion noticed both in angiocardiography or 2-dimensional echocardiography were assessed by ECG gated blood pool scan (GBPS). Endless cine loop image, phase and amplitude images and paradox image obtained by visual inspection of each cardiac beat or Fourier transformation of acquired raw data were investigated to determine the incremental value of GBPS with these processing methods for identification of paradoxical ventricular wall motion. The results were as follows:1) Paradoxical wall motions were observed on interventricular septum in 34 cases, left ventricular free wall in 26 and right ventricular wall in 24. Underlying heart diseases were is chemic (23 cases) valvular(9), congenital heart disease (12), cardiomyopathy (5), pericardial effusion(5), post cardiac surgery(3), corpulmonale (2), endocarditis (l) and right ventricular tumor(l). 2) Left ventricular ejection fractions of patients with paradoxical left ventricular wall motion were significantly lower than those with paradoxical septal motion (p <0.005). 3) The sensitivity of each processing methods for detecting paradoxical wall motion was 76.9% by phase analysis, 74.6% by endless cine loop mapping and 68.4% by paradox image manipulation respectively. Paradoxial motions visualized only in phase, paradox or both images were appeared as hypokinesia or akinesia in cine loop image. 4) All events could be identified by at least one of above three processing methods, however only 34 cases (48.4%) showed the paradoxical motions in all of the three images. By these findings, we concluded that simultaneous inspection of all above three processing methods-endless cine loop, phase analysis and paradox image is necessary for accurate identification and assessment of paradoxical ventricular wall motion when performing GBPS.

  18. Assessment of 123I-β-methyl iodophenyl pentadecanoic acid (BMIPP) myocardial scintigraphy in patients of chronic right ventricular overload. Fatty acid metabolism in right ventricular myocardium

    International Nuclear Information System (INIS)

    Mutoh, Hiroshi

    1997-01-01

    An investigation on the right ventricular pressure level and the abnormalities in the fatty acid metabolism of myocardium was made using 123 I-βmethyl-iodophenyl pentadecanoic acid (BMIPP) myocardial SPECT in patients with chronic right ventricular overloading. Twenty patients who presented with right ventricular systolic pressure (RVSP) of 35 mmHg or more were used as the subjects. Dual myocardial SPECT with 201 TlCl (Tl) and BMIPP was carried out for the subjects and RVc/LVc, a ratio of radioactivity count incorporated in the right ventricular free wall to the left one was determined for Tl and BMIPP. And the correlations between RVc/LVc and RVSP, and RVc/LVc and RVSP/LVSP were examined. The subjects were classified into 3 groups based on the RVSP levels and the count ratio, BMIPP/Tl was compared among the three groups. With respect of Tl uptake, there were significant, positive correlations between RVc/LVc and RVSP (correlation coefficient r=0.51, p<0.05) and between RVc/LVc and RVSP/LVSP (correlation coefficient r=0.59, p<0.01). On the other hand, no significant correlation was found between them with respect of the uptake of BMIPP. The BMIPP/Tl ratio in the group with higher than 80 mmHg of RVSP was 0.82±0.06, which was significantly lower than the ratio's for two groups of less than 80 mmHg; 0.91±0.07 and 0.98±0.04 in the group with 35-49 and 50-79 mmHg of RVSP, respectively. These results show that when compared with BMIPP, Tl is superior for the estimation of right ventricular pressure. For the patients with right ventricular overloading, it was suggested that when RVSP reaches 80 mmHg or more, there appear some disorders in the fatty acid metabolism in the right ventricular myocardium. (author)

  19. Impact of early, late, and no ST-segment resolution measured by continuous ST Holter monitoring on left ventricular ejection fraction and infarct size as determined by cardiovascular magnetic resonance imaging

    NARCIS (Netherlands)

    Haeck, Joost D. E.; Verouden, Niels J. W.; Kuijt, Wichert J.; Koch, Karel T.; Majidi, Mohamed; Hirsch, Alexander; Tijssen, Jan G. P.; Krucoff, Mitchell W.; de Winter, Robbert J.

    2011-01-01

    Background: The goal of this study is to determine the predictive value of ST-segment resolution (STR) early after percutaneous coronary intervention (PCI), late STR, and no STR for left ventricular ejection fraction (LVEF) and infarct size (IS) by cardiovascular magnetic resonance (CMR) at

  20. Photographic assessment of burn size and depth: reliability and validity

    NARCIS (Netherlands)

    Hop, M.; Moues, C.; Bogomolova, K.; Nieuwenhuis, M.; Oen, I.; Middelkoop, E.; Breederveld, R.; de Baar, M.

    2014-01-01

    Objective: The aim of this study was to examine the reliability and validity of using photographs of burns to assess both burn size and depth. Method: Fifty randomly selected photographs taken on day 0-1 post burn were assessed by seven burn experts and eight referring physicians. Inter-rater

  1. Cardiac MRI assessment of right ventricular function: impact of right bundle branch block on the evaluation of cardiac performance parameters

    Energy Technology Data Exchange (ETDEWEB)

    Marterer, Robert; Tschauner, Sebastian; Sorantin, Erich [Medical University of Graz, Division of Pediatric Radiology, Department of Radiology, Graz (Austria); Zeng, Hongchun [First Affiliated Hospital of Xinjiang Medical University, Department of Ultrasonography, Urumqi (China); Koestenberger, Martin [Medical University of Graz, Division of Pediatric Cardiology, Department of Pediatrics and Adolescent Medicine, Graz (Austria)

    2015-12-15

    Right ventricular (RV) function represents a prognostic marker in patients with corrected congenital heart disease. In up to 80 % of these patients, right branch bundle block (RBBB) exists and leads to asynchronous ventricular contraction. The aim of this retrospective study was to evaluate the change of RV performance parameters considering delayed RV end-systolic contraction. RV volumes of 33 patients were assessed twice: 1) not taking account of RBBB (group I), and 2) considering RBBB (group II). According to the RV ejection fraction (EF) for both groups, RV function was classified in different categories (>50 % = normal, 40-50 % = mildly-, 30-40 % = moderately-, <30 % = severely-reduced). The mean time difference between maximal systolic contraction of the septum and RV free wall was 90.7 ms ± 42.6. Consequently, RV end-systolic volume was significantly decreased in group II (p < 0.001). Accordingly, RV stroke volume and RV EF were significantly higher in group II (p < 0.001). There was also a significant change in the assessment of RV function (p < 0.02). RBBB induced delayed RV contraction can be detected at CMR. Ignoring the RV physiology in RBBB patients leads to a statistically significant underscoring of RV performance parameters. (orig.)

  2. Quantitative relationships between thallium-201 estimated myocardial infarct size and left ventricular function in the acute or convalescent phase of the first attack of myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Kataoka, Hajime (Kagoshima Univ. (Japan). Faculty of Medicine); Ueda, Keiji; Sakai, Makoto (and others)

    1983-07-01

    Correlations between left ventricular (LV) function and infarct size estimated by computer-assisted thallium (Tl)-201 scintigraphy were studied in 16 patients in the acute or convalescent phase of the first attack of transmural myocardial infarction (MI). Tl-201 estimation of the infarct size was done using a ''corrected'' circumferential profile method, by which the total defect score could be obtained. The LV function was evaluated by radionuclide angiography, echocardiography and cardiac catheterization study. The following results were obtained: 1) A close inverse relationship was found between the defect score and the ejection fraction (r = -0.649, p < 0.01). 2) The linear correlation coefficient was 0.540 (p < 0.05) between the defect score and the pulmonary arterial end-diastolic pressure and -0.616 (p < 0.02) between the defect score and the stroke volume index. There was no significant correlation between the defect score and the cardiac index. 3) There was a linear correlation between the defect score and the LV end-diastolic dimension (r = -0.852, p < 0.001). However, there was no relation between the defect score and the left atrial dimension. When the LV indices were compared between the small (S) and the large (L) defect score group, the L defect group had faster heart rate, larger LV chamber size and the smaller stroke volume index than the S defect group. However, there was no significant difference in the cardiac index between these 2 groups. These results suggest that the LV dilatation in acute or convalescent phase of the first attack of transmural MI is an ominous sign because it was usually accompanied by large infarct size. The present study also indicates that LV dilatation accompanying a large infarct does not satisfactorily compensate for LV dysfunction by Frank-Starling mechanism.

  3. Can blind persons accurately assess body size from the voice?

    Science.gov (United States)

    Pisanski, Katarzyna; Oleszkiewicz, Anna; Sorokowska, Agnieszka

    2016-04-01

    Vocal tract resonances provide reliable information about a speaker's body size that human listeners use for biosocial judgements as well as speech recognition. Although humans can accurately assess men's relative body size from the voice alone, how this ability is acquired remains unknown. In this study, we test the prediction that accurate voice-based size estimation is possible without prior audiovisual experience linking low frequencies to large bodies. Ninety-one healthy congenitally or early blind, late blind and sighted adults (aged 20-65) participated in the study. On the basis of vowel sounds alone, participants assessed the relative body sizes of male pairs of varying heights. Accuracy of voice-based body size assessments significantly exceeded chance and did not differ among participants who were sighted, or congenitally blind or who had lost their sight later in life. Accuracy increased significantly with relative differences in physical height between men, suggesting that both blind and sighted participants used reliable vocal cues to size (i.e. vocal tract resonances). Our findings demonstrate that prior visual experience is not necessary for accurate body size estimation. This capacity, integral to both nonverbal communication and speech perception, may be present at birth or may generalize from broader cross-modal correspondences. © 2016 The Author(s).

  4. Automated Assessment of Left Ventricular Function and Mass Using Heart Deformation Analysis: Initial Experience in 160 Older Adults.

    Science.gov (United States)

    Lin, Kai; Collins, Jeremy D; Lloyd-Jones, Donald M; Jolly, Marie-Pierre; Li, Debiao; Markl, Michael; Carr, James C

    2016-03-01

    To assess the performance of automated quantification of left ventricular function and mass based on heart deformation analysis (HDA) in asymptomatic older adults. This study complied with Health Insurance Portability and Accountability Act regulations. Following the approval of the institutional review board, 160 asymptomatic older participants were recruited for cardiac magnetic resonance imaging including two-dimensional cine images covering the entire left ventricle in short-axis view. Data analysis included the calculation of left ventricular ejection fraction (LVEF), left ventricular mass (LVM), and cardiac output (CO) using HDA and standard global cardiac function analysis (delineation of end-systolic and end-diastolic left ventricle epi- and endocardial borders). The agreement between methods was evaluated using intraclass correlation coefficient (ICC) and coefficient of variation (CoV). HDA had a shorter processing time than the standard method (1.5 ± 0.3 min/case vs. 5.8 ± 1.4 min/case, P HDA. There was a systemic bias toward lower LVEF (62.8% ± 8.3% vs. 69.3% ± 6.7%, P HDA compared to the standard technique. Conversely, HDA overestimated LVM (114.8 ± 30.1 g vs. 100.2 ± 29.0 g, P HDA has the potential to measure LVEF, CO, and LVM without the need for user interaction based on standard cardiac two-dimensional cine images. Copyright © 2015 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  5. Assessment of ventricular excitation propagation velocity using intramyocardial electrograms and electron beam tomography images

    International Nuclear Information System (INIS)

    Kraft, A.; Schreier, G.; Hutten, H.; Kastner, P.; Rienmueller, R.; Grasser, B; Iberer, F.; Tscheliessnigg, K.H.

    1999-01-01

    The combination of intramyocardial electrogram (IEGM) recordings and 3D-reconstruction of the heart allows to relate electrophysiological with geometrical parameters of the heart. In 12 Heart transplants the distance of two epimyocardially implanted pacemaker leads d x and the propagation time f x have been correlated. Linear regression analysis revealed significant (p < 0,002) and strong (r = 0,82) correlation. The ventricular excitation propagation velocity (VEPV) within the examined patient group was found to be 0,53 m/s with an offset of 14.25 mm, which is caused by the extent of the electrodes and the region of early capture immediately after stimulation. (author)

  6. Thallium-201 myocardial imaging in children with heart disease. Quantitative assessment of right ventricular pressure

    Energy Technology Data Exchange (ETDEWEB)

    Mitomori, Toshihiro; Ono, Yasuo; Kamiya, Tetsuro; Nishimura, Tsunehiko; Kozuka, Takahiro (National Cardiovascular Center, Suita, Osaka (Japan)); Kohata, Tohru; Tanimoto, Takeshi

    1985-02-01

    201-TlCl myocardial imaging studies were performed to evaluate systolic pressure of right ventricle on 107 patients including 89 patients with congenital cardiac disease, patients with primary pulmonary hypertension and 13 patients with history of MCLS with the age range of 2 months to 17 years. The congenital cardiac disease group included 30 patients with tetralogy of Fallot, 8 patients with pulmonary stenosis (included 1 patient with double chambered right ventricle), 20 patients with ventricular septal defect, 10 patients with patent ductus arteriosus, 9 patients with atrial septal defect and 12 patients with complete transposition of great arteries. None of the patients with history of MCLS had coronary involvement. 50 ..mu..Ci/kg of 201-TlCl was infused intravenously and after 15 minutes the images were obtained from 5 directions (anterior, LAO 30, LAO 45, LAO 60 and lateral). The angle was determined to demonstrate the intraventricular septum and ventricular free walls cleary separated. The image of end-diastolic phase was obtained with ECG synchronized gated method from that direction. The ROI (region of interest) was defined as a slice line by drawing two lines perpendicular to the septum and the counts of the left and right ventricular free wall (Cl and Cr) were analyzed to evaluate the pressure of right ventricle. The pressure of ventricles were obtained by cardiac catheterization performed at the same time with myocardial imaging. The ratio of Cl and Cr (Cr/Cl) had good correlation with the ratio of peak systolic pressure of left ventricle and right ventricle (regression equation Y=0.84X + 0.08, r=0.87). In each congenital heart disease group, very good correlation was also demonstrated (Y=1.46X - 0.30, r=0.96 in PS; Y=0.70X0.20, r=0.91 in VSD; Y=0.86X + 0.15, r=0.78 in ASD and Y=0.72X + 0.24, r=0.80 in PDA). Thus 201-TlCl myocardial imaging was useful method to evaluate right ventricular pressure noninvasively in congenital cardiac disease.

  7. Left ventricular diastolic performance at rest in patients with angina and normal systolic function - assessment by equilibrium radionuclide angiography

    International Nuclear Information System (INIS)

    Maini, C.L.; Bonetti, M.G.; Valle, G.; Antonelli Incalzi, R.; Montenero, A.S.

    1985-01-01

    The aim of the study was to correlate diastolic function, as evaluated by peak filling rate (PFR) and relative time (TPFR), with the severity of ischemic heart disease, as evaluated by exercise electrocardiography. Accordingly, 83 ischemic patients with effort angina, but normal ejection function at rest and normal left ventricular size, were studied by equilibrium radionuclide angiocardiography within two weeks from the exercise ECG. Diastolic dysfunction, as determined from PFR and, to a lesser extent, from TPFR, is common in patients with ischemic heart disease and normal systolic function. The prevalence and severity of such dysfunction is related more to the severity of the ischemia, as evaluated by the exercise ECG, than to the presence of an old myocardial infarction. Such findings are consistent with the hypothesis that PFR reflects mainly the early diastolic active uncoupling process. (orig.) [de

  8. Association between the resolution of the ST with microvascular obstruction and the size of the infarction assessed by cardiac magnetic resonance imaging

    International Nuclear Information System (INIS)

    Lluveras, N.; Parma, G.; Florio, L; Zamoro, J

    2012-01-01

    The absence of ST-segment resolution (STR) in patients with an ST-elevation myocardial infarction (STEMI) after reperfusion strategy has been related to impaired myocardial perfusion. This is likely due to extensive microvascular obstruction (MVO) and reperfusion tissue injury. The aim of the study was to analyze the value of STR in the prediction of infarct size, perfusion impairment and left ventricular function assessed with cardiac magnetic resonance (CMR) in acute STEMI

  9. Problems in clinical assessment of left ventricular peak filling rate with radionuclide ventriculography

    Energy Technology Data Exchange (ETDEWEB)

    Ishida, Yoshio; Kim, Bong-Ha; Tsuneoka, Yutaka

    1987-02-01

    With an increased clinical application of early peak diastolic filling rate (PFR) using radionuclide ventriculography, problems of its clinical significance have emerged. The study was designed to answer the following questions: 1) accuracy of PFR measurement, 2) normalization of PFR, and 3) whether PFR may reflect left ventricular relaxation rate (LVRR). In measuring PFR, an elevated framing rate was required, and the optimal rate was 20 msec/F. Second sound heart gating technique proved to be complementary to conventional ECG R wave gating technique in the evaluation of left ventricular diastolic volume curves and mean filling rate associated with changes in the range of R-R interval. PFR which was normalized with end-diastolic volume (EDV) did not necessarily reflect measured PFR because of individual differences of EDV. An experiment on the relationship of mitral valve pressure to blood flow in dogs revealed that PFR was influenced by not only LVRR but also left atrial pressure. These results may raise a question of the rationale for using the measurement of PFR, as well as its technical problems, in the objective evaluation of LVRR. (Namekawa, K.).

  10. Improved left ventricular function after growth hormone replacement in patients with hypopituitarism: assessment with radionuclide angiography

    International Nuclear Information System (INIS)

    Cuocolo, A.; Nicolai, E.; Colao, A.; Longobardi, S.; Cardei, S.; Fazio, S.; Merola, B.; Lombardi, G.; Sacca, L.; Salvatore, M.

    1996-01-01

    Prolonged growth hormone deficiency (GHD) leads to marked cardiac dysfunction; however, whether reversal of this abnormality may be achieved after specific replacement therapy has not yet been completely clarified. Fourteen patients with childhood-onset GHD (nine men and five women, mean age 27±4 years) and 12 normal control subjects underwent equilibrium radionuclide angiography under control conditions at rest. Patients with GHD were also studied 6 months after recombinant human (rh) GH treatment (0.05 IU/kg per day). Normal control subjects and patients with GHD did not differ with respect to age, gender and heart rate. In contrast, left ventricular ejection fraction (53%±9% vs 66%±6%, P 2 , P 2 , P 2 , P 2 , P <0.01) was observed in GHD patients. In conclusion, prolonged lack of GH leads to impaired left ventricular function at rest. Reversal of this abnormality may be observed after 6 months of specific replacement therapy in patients with childhood-onset GHD. (orig.). With 4 figs., 1 tab

  11. Experimental Assessment of the Hydraulics of a Miniature Axial-Flow Left Ventricular Assist Device

    Science.gov (United States)

    Smith, P. Alex; Cohn, William; Metcalfe, Ralph

    2017-11-01

    A minimally invasive partial-support left ventricular assist device (LVAD) has been proposed with a flow path from the left atrium to the arterial system to reduce left ventricular stroke work. In LVAD design, peak and average efficiency must be balanced over the operating range to reduce blood trauma. Axial flow pumps have many geometric parameters. Until recently, testing all these parameters was impractical, but modern 3D printing technology enables multi-parameter studies. Following theoretical design, experimental hydraulic evaluation in steady state conditions examines pressure, flow, pressure-flow gradient, efficiency, torque, and axial force as output parameters. Preliminary results suggest that impeller blades and stator vanes with higher inlet angles than recommended by mean line theory (MLT) produce flatter gradients and broader efficiency curves, increasing compatibility with heart physiology. These blades also produce less axial force, which reduces bearing load. However, they require slightly higher torque, which is more demanding of the motor. MLT is a low order, empirical model developed on large pumps. It does not account for the significant viscous losses in small pumps like LVADs. This emphasizes the importance of experimental testing for hydraulic design. Roderick D MacDonald Research Fund.

  12. Using impedance cardiography to assess left ventricular systolic function via postural change in patients with heart failure.

    Science.gov (United States)

    DeMarzo, Arthur P; Calvin, James E; Kelly, Russell F; Stamos, Thomas D

    2005-01-01

    For the diagnosis and management of heart failure, it would be useful to have a simple point-of-care test for assessing ventricular function that could be performed by a nurse. An impedance cardiography (ICG) parameter called systolic amplitude (SA) can serve as an indicator of left ventricular systolic function (LVSF). This study tested the hypothesis that patients with normal LVSF should have a significant increase in SA in response to an increase in end-diastolic volume caused by postural change from sitting upright to supine, while patients with depressed LVSF associated with heart failure should have a minimal increase or a decrease in SA from upright to supine. ICG data were obtained in 12 patients without heart disease and with normal LVSF and 18 patients with clinically diagnosed heart failure. Consistent with the hypothesis, patients with normal LVSF had a significant increase in SA from upright to supine, whereas heart failure patients had a minimal increase or a decrease in SA from upright to supine. This ICG procedure may be useful for monitoring the trend of patient response to titration of beta blockers and other medications. ICG potentially could be used to detect worsening LVSF and provide a means of measurement for adjusting treatment.

  13. Quantitative assessment of left ventricular function with dual-source CT in comparison to cardiac magnetic resonance imaging: initial findings

    Energy Technology Data Exchange (ETDEWEB)

    Busch, S.; Johnson, T.R.C.; Wintersperger, B.J.; Minaifar, N.; Bhargava, A.; Rist, C.; Reiser, M.F.; Becker, C.; Nikolaou, K. [University of Munich, Department of Clinical Radiology, Munich (Germany)

    2008-03-15

    Cardiac magnetic resonance imaging and echocardiography are currently regarded as standard modalities for the quantification of left ventricular volumes and ejection fraction. With the recent introduction of dual-source computedtomography (DSCT), the increased temporal resolution of 83 ms should also improve the assessment of cardiac function in CT. The aim of this study was to evaluate the accuracy of DSCT in the assessment of left ventricular functional parameters with cardiac magnetic resonance imaging (MRI) as standard of reference. Fifteen patients (two female, 13 male; mean age 50.8 {+-} 19.2 years) underwent CT and MRI examinations on a DSCT (Somatom Definition; Siemens Medical Solutions, Forchheim, Germany) and a 3.0-Tesla MR scanner (Magnetom Trio; Siemens Medical Solutions), respectively. Multiphase axial CT images were analysed with a semiautomatic region growing algorithms (Syngo Circulation; Siemens Medical Solutions) by two independent blinded observers. In MRI, dynamic cine loops of short axis slices were evaluated with semiautomatic contour detection software (ARGUS; Siemens Medical Solutions) independently by two readers. End-systolic volume (ESV), end-diastolic volume (EDV), ejection fraction (EF) and stroke volume (SV) were determined for both modalities, and correlation coefficient, systematic error, limits of agreement and inter-observer variability were assessed. In DSCT, EDV and ESV were 135.8 {+-} 41.9 ml and 54.9 {+-} 29.6 ml, respectively, compared with 132.1 {+-} 40.8 ml EDV and 57.6 {+-} 27.3 ml ESV in MRI. Thus, EDV was overestimated by 3.7 ml (limits of agreement -46.1/+53.6), while ESV was underestimated by 2.6 ml (-36.6/+31.4). Mean EF was 61.6 {+-} 12.4% in DSCT and 57.9 {+-} 9.0% in MRI, resulting in an overestimation of EF by 3.8% with limits of agreement at -14.7 and +22.2%. Rank correlation rho values were 0.81 for EDV (P = 0.0024), 0.79 for ESV (P = 0.0031) and 0.64 for EF (P = 0.0168). The kappa value of inter

  14. Quantitative assessment of left ventricular function with dual-source CT in comparison to cardiac magnetic resonance imaging: initial findings

    International Nuclear Information System (INIS)

    Busch, S.; Johnson, T.R.C.; Wintersperger, B.J.; Minaifar, N.; Bhargava, A.; Rist, C.; Reiser, M.F.; Becker, C.; Nikolaou, K.

    2008-01-01

    Cardiac magnetic resonance imaging and echocardiography are currently regarded as standard modalities for the quantification of left ventricular volumes and ejection fraction. With the recent introduction of dual-source computedtomography (DSCT), the increased temporal resolution of 83 ms should also improve the assessment of cardiac function in CT. The aim of this study was to evaluate the accuracy of DSCT in the assessment of left ventricular functional parameters with cardiac magnetic resonance imaging (MRI) as standard of reference. Fifteen patients (two female, 13 male; mean age 50.8 ± 19.2 years) underwent CT and MRI examinations on a DSCT (Somatom Definition; Siemens Medical Solutions, Forchheim, Germany) and a 3.0-Tesla MR scanner (Magnetom Trio; Siemens Medical Solutions), respectively. Multiphase axial CT images were analysed with a semiautomatic region growing algorithms (Syngo Circulation; Siemens Medical Solutions) by two independent blinded observers. In MRI, dynamic cine loops of short axis slices were evaluated with semiautomatic contour detection software (ARGUS; Siemens Medical Solutions) independently by two readers. End-systolic volume (ESV), end-diastolic volume (EDV), ejection fraction (EF) and stroke volume (SV) were determined for both modalities, and correlation coefficient, systematic error, limits of agreement and inter-observer variability were assessed. In DSCT, EDV and ESV were 135.8 ± 41.9 ml and 54.9 ± 29.6 ml, respectively, compared with 132.1 ± 40.8 ml EDV and 57.6 ± 27.3 ml ESV in MRI. Thus, EDV was overestimated by 3.7 ml (limits of agreement -46.1/+53.6), while ESV was underestimated by 2.6 ml (-36.6/+31.4). Mean EF was 61.6 ± 12.4% in DSCT and 57.9 ± 9.0% in MRI, resulting in an overestimation of EF by 3.8% with limits of agreement at -14.7 and +22.2%. Rank correlation rho values were 0.81 for EDV (P = 0.0024), 0.79 for ESV (P 0.0031) and 0.64 for EF (P = 0.0168). The kappa value of inter-observer variability were

  15. Left ventricular torsion assessed by two-dimensional echocardiography speckle tracking as a predictor of left ventricular remodeling and short-term outcome following primary percutaneous coronary intervention for acute myocardial infarction: A single-center experience.

    Science.gov (United States)

    Awadalla, Hany; Saleh, Mohamed Ayman; Abdel Kader, Mohamed; Mansour, Amr

    2017-08-01

    Left ventricular (LV) torsion is a novel method to assess systolic LV function. This study aimed at exploring the utility of 2D speckle tracking-based assessment of left ventricular torsion in patients with acute myocardial infarction (AMI) undertaking primary percutaneous intervention (pPCI) in predicting left ventricular remodeling. The study included 115 patients (mean±SD, age 52.2±9.67, males 84.3%) who underwent pPCI for AMI. Echocardiographic assessment of LV torsion by two-dimensional speckle tracking was performed early after the index pPCI. Patients underwent repeat echocardiography at 6 months to detect remodeling. LV torsion in the acute setting was significantly lower in those who demonstrated LV remodeling at follow-up compared to those without remodeling (7.56±1.95 vs 15.16±4.65; P<.005). Multivariate analysis identified peak CK & CK-MB elevation (β=-0.767 and -0.725; P<.001), SWMA index (β=-0.843; P<.001), and Simpson's derived LV ejection fraction (LVEF; β=0.802; P<.001) as independent predictors of baseline LV torsion. It also identified peak LV torsion (β: 0.27; 95% CI: 0.15-0.5, P=.001) and SWMA index (β: 1.07, 95% CI: 1.03-1.12, P=.005) as independent predictors of LV remodeling. Baseline Killip's grades II and higher (β: 48.6; 95% CI 5.5-428, P<.001) and diabetes mellitus (β: 29.7; 95% CI 1.1-763, P<.05) were independent predictors of mortality. Left ventricular torsion in acute MI setting is impaired and predicts subsequent LV remodeling at 6-month follow-up. © 2017, Wiley Periodicals, Inc.

  16. Estimation of portion size in children's dietary assessment: lessons learnt.

    Science.gov (United States)

    Foster, E; Adamson, A J; Anderson, A S; Barton, K L; Wrieden, W L

    2009-02-01

    Assessing the dietary intake of young children is challenging. In any 1 day, children may have several carers responsible for providing them with their dietary requirements, and once children reach school age, traditional methods such as weighing all items consumed become impractical. As an alternative to weighed records, food portion size assessment tools are available to assist subjects in estimating the amounts of foods consumed. Existing food photographs designed for use with adults and based on adult portion sizes have been found to be inappropriate for use with children. This article presents a review and summary of a body of work carried out to improve the estimation of portion sizes consumed by children. Feasibility work was undertaken to determine the accuracy and precision of three portion size assessment tools; food photographs, food models and a computer-based Interactive Portion Size Assessment System (IPSAS). These tools were based on portion sizes served to children during the National Diet and Nutrition Survey. As children often do not consume all of the food served to them, smaller portions were included in each tool for estimation of leftovers. The tools covered 22 foods, which children commonly consume. Children were served known amounts of each food and leftovers were recorded. They were then asked to estimate both the amount of food that they were served and the amount of any food leftover. Children were found to estimate food portion size with an accuracy approaching that of adults using both the food photographs and IPSAS. Further development is underway to increase the number of food photographs and to develop IPSAS to cover a much wider range of foods and to validate the use of these tools in a 'real life' setting.

  17. Myocardial perfusion SPECT for assessment of left ventricular function and volume- comparison with echocardiography

    International Nuclear Information System (INIS)

    Cheng Xu; Huang Gang

    2004-01-01

    Objective: The purpose of this study was to evaluate left ventricular volume and function by gated SPECT and comparison of the results with echocardiography. Methods: 65 Consecutive patients (49 male, 16 female; mean age 61+11 years) who underwent both gated 99m Tc-MIBI myocardial perfusion SPECT and echocardiography within a 15 days period were included in the study. Exclusion criteria were any change in clinical status between acquisition of the gated SPECT and echocardiography studies, acute myocardial infarction occurring less than 7 days before study, and surgical procedures occurring within 30 days of the study. The clinical diagnosis of each patient was not considered, as this was not relevant to the purpose of the study. The diagnoses were as follows: coronary artery disease (n=46), hypertensive heart disease (n=8), old myocardial infarction (n=5), myocarditis (n=2), and routine medical examination(n=4). A dose of 740 MBq of 99 Tc m -sestamibi was administered in resting condition. Gated SPECT images were obtained with ADAC Vertex MCD-AC SPECT system. The raw projection images were reconstructed with filtered back-projection (ramp filter), without attenuation correction. The data, including left ventricular ejection fraction (LVEF), end-diastolic volume (EDV), end-systolic volume (ESV) were obtained using AUTOQUANT software (ADAC corporation). The echocardiography study used its standard techniques. Two nuclear medicine physicians processed the raw images respectively to evaluate internal reproducibility of gated SPECT. In order to compare the results of gated SPECT with echocardiography on different left ventricular volumes, all patients were divided into two groups (EDV 90 ml, n=34) based by EDV measurements in echocardiography. Results: The correlation coefficient of LVEF, EDV, ESV between SPECT and echocardiography were 0.77, 0.86 and 0.90 respectively. P 0.07). The reproducibility of gated SPECT was excellent. There were no significant differences in

  18. Beat-to-beat left ventricular performance in atrial fibrillation: radionuclide assessment with the computerized nuclear probe

    International Nuclear Information System (INIS)

    Schneider, J.; Berger, H.J.; Sands, M.J.; Lachman, A.B.; Zaret, B.L.

    1983-01-01

    There is wide beat-to-beat variability in cycle length and left ventricular performance in patients with atrial fibrillation. In this study, left ventricular ejection fraction and relative left ventricular volumes were evaluated on a beat-to-beat basis with the computerized nuclear probe, an instrument with sufficiently high sensitivity to allow continuous evaluation of the radionuclide time-activity curve. Of 18 patients with atrial fibrillation, 5 had mitral stenosis, 6 had mitral regurgitation, and 7 had coronary artery disease. Fifty consecutive beats were analyzed in each patient. The mean left ventricular ejection fraction ranged from 17 to 51%. There was substantial beat-to-beat variation in cycle length and left ventricular ejection fraction in all patients, including those with marked left ventricular dysfunction. In 14 patients who also underwent multiple gated cardiac blood pool imaging, there was an excellent correlation between mean ejection fraction derived from the nuclear probe and gated ejection fraction obtained by gamma camera imaging (r . 0.90). Based on beat-to-beat analysis, left ventricular function was dependent on relative end-diastolic volume and multiple preceding cycle lengths, but not preceding end-systolic volumes. This study demonstrates that a single value for left ventricular ejection fraction does not adequately characterize left ventricular function in patients with atrial fibrillation. Furthermore, both the mean beat-to-beat and the gated ejection fraction may underestimate left ventricular performance at rest in such patients

  19. Quantitative assessment of pulmonary regurgitation in patients with and without right ventricular tract obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Spiewak, Mateusz, E-mail: mspiewak@ikard.pl [Department of Coronary Artery Disease and Structural Heart Diseases, Institute of Cardiology, ul. Alpejska 42, 04-628 Warsaw (Poland); Cardiovascular Magnetic Resonance Unit, Institute of Cardiology, ul. Alpejska 42, 04-628 Warsaw (Poland); Biernacka, Elzbieta K., E-mail: kbiernacka@ikard.pl [Department of Congenital Heart Diseases, Institute of Cardiology, ul. Alpejska 42, 04-628 Warsaw (Poland); Malek, Lukasz A., E-mail: lmalek@ikard.pl [Cardiovascular Magnetic Resonance Unit, Institute of Cardiology, ul. Alpejska 42, 04-628 Warsaw (Poland); Department of Interventional Cardiology and Angiology, Institute of Cardiology, ul. Alpejska 42, 04-628 Warsaw (Poland); Misko, Jolanta, E-mail: jmisko@wp.pl [Cardiovascular Magnetic Resonance Unit, Institute of Cardiology, ul. Alpejska 42, 04-628 Warsaw (Poland); Department of Radiology, Institute of Cardiology, ul. Alpejska 42, 04-628 Warsaw (Poland); Kowalski, Miroslaw, E-mail: mkowalski@ikard.pl [Department of Congenital Heart Diseases, Institute of Cardiology, ul. Alpejska 42, 04-628 Warsaw (Poland); Milosz, Barbara, E-mail: barbara-milosz@o2.pl [Cardiovascular Magnetic Resonance Unit, Institute of Cardiology, ul. Alpejska 42, 04-628 Warsaw (Poland); Department of Radiology, Institute of Cardiology, ul. Alpejska 42, 04-628 Warsaw (Poland); Petryka, Joanna, E-mail: joannapetryka@hotmail.com [Department of Coronary Artery Disease and Structural Heart Diseases, Institute of Cardiology, ul. Alpejska 42, 04-628 Warsaw (Poland); Cardiovascular Magnetic Resonance Unit, Institute of Cardiology, ul. Alpejska 42, 04-628 Warsaw (Poland); Zabicka, Magdalena, E-mail: mzabicka@onet.eu [Cardiovascular Magnetic Resonance Unit, Institute of Cardiology, ul. Alpejska 42, 04-628 Warsaw (Poland); Dept. of Radiology, Inst. of Cardiology, ul. Alpejska 42, 04-628 Warsaw (Poland); Ruzyllo, Witold, E-mail: wruzyllo@ikard.pl [Inst. of Cardiology, ul. Alpejska 42, 04-628 Warsaw (Poland)

    2011-11-15

    Background: There are concerns whether there is a difference in clinical utility of pulmonary regurgitation (PR) fraction (PRF) and PR volume (PRV) in subgroups of patients with isolated PR and individuals with combined PR and right ventricular outflow tract obstruction (RVOTO). The aim of the study was to compare PRF and PRV in patients with or without RVOTO. Methods and results: 82 consecutive patients after repair of tetralogy of Fallot (TOF) who underwent cardiovascular magnetic resonance and echocardiography were studied. There was no difference in PRF between patients with moderate and severe right ventricular (RV) dilatation (32 {+-} 13% vs. 37 {+-} 12%; p = 0.18). Significant difference in PRV was observed between these groups (23 {+-} 10 ml/m{sup 2} vs. 31 {+-} 12 ml/m{sup 2}, respectively; p = 0.02). PRV had better ability than PRF in identification of severe RV dilatation, both in group with RVOTO [area under the curve (AUC) 0.82 vs. 0.72, p = 0.005] and in patients without RVOTO (AUC 0.83 vs. 0.77, p = 0.04). A strong correlation was seen between PRF and PRV both in patients with and without RVOTO [r = 0.93, p < 0.0001 and r = 0.92, p < 0.0001, respectively]. In both subgroups high variability of PRF was found in subjects with similar degree of PRV. Conclusions: PRV shows better ability than PRF in evaluating influence of PR on RV in patients after TOF repair, both in population with and without concomitant RVOTO.

  20. Quantitative assessment of pulmonary regurgitation in patients with and without right ventricular tract obstruction

    International Nuclear Information System (INIS)

    Spiewak, Mateusz; Biernacka, Elzbieta K.; Malek, Lukasz A.; Misko, Jolanta; Kowalski, Miroslaw; Milosz, Barbara; Petryka, Joanna; Zabicka, Magdalena; Ruzyllo, Witold

    2011-01-01

    Background: There are concerns whether there is a difference in clinical utility of pulmonary regurgitation (PR) fraction (PRF) and PR volume (PRV) in subgroups of patients with isolated PR and individuals with combined PR and right ventricular outflow tract obstruction (RVOTO). The aim of the study was to compare PRF and PRV in patients with or without RVOTO. Methods and results: 82 consecutive patients after repair of tetralogy of Fallot (TOF) who underwent cardiovascular magnetic resonance and echocardiography were studied. There was no difference in PRF between patients with moderate and severe right ventricular (RV) dilatation (32 ± 13% vs. 37 ± 12%; p = 0.18). Significant difference in PRV was observed between these groups (23 ± 10 ml/m 2 vs. 31 ± 12 ml/m 2 , respectively; p = 0.02). PRV had better ability than PRF in identification of severe RV dilatation, both in group with RVOTO [area under the curve (AUC) 0.82 vs. 0.72, p = 0.005] and in patients without RVOTO (AUC 0.83 vs. 0.77, p = 0.04). A strong correlation was seen between PRF and PRV both in patients with and without RVOTO [r = 0.93, p < 0.0001 and r = 0.92, p < 0.0001, respectively]. In both subgroups high variability of PRF was found in subjects with similar degree of PRV. Conclusions: PRV shows better ability than PRF in evaluating influence of PR on RV in patients after TOF repair, both in population with and without concomitant RVOTO.

  1. Small-sized conduits in the right ventricular outflow tract in young children: bicuspidalized homografts are a good alternative to standard conduits.

    Science.gov (United States)

    François, Katrien; De Groote, Katya; Vandekerckhove, Kristof; De Wilde, Hans; De Wolf, Daniel; Bové, Thierry

    2017-10-03

    Downsizing a homograft (HG) through bicuspidalization has been used for more than 2 decades to overcome the shortage of small-sized conduits for reconstruction of the right ventricular outflow tract (RVOT) in young children. Our goal was to investigate the durability of bicuspidalized HGs compared with other small HGs. A retrospective analysis of 93 conduits ≤20 mm, implanted over 23 years, was performed. The end-points were survival, structural valve degeneration and conduit replacement. The conduits comprised 40 pulmonary HGs, 12 aortic HGs, 17 bicuspidalized HGs and 24 xenografts. The median age, mean conduit diameter and z-value at implantation were 1.4 (interquartile range 0.3-3) years, 16.5 ± 2.7 mm and 2.8 ± 1.3, respectively. Valve position was heterotopic in 59 patients and orthotopic in 34 patients. At a mean follow-up period of 7.6 ± 5.9 years, the hospital survival rate was 89%. Freedom from explant at 5 and 10 years was 83 ± 5% and 52 ± 6%, respectively. Freedom from structural valve degeneration was 79 ± 5% at 5 years and 47 ± 6% at 10 years [68 ± 8% for pulmonary HG, 42 ± 16% for bicuspidalized HG, 31 ± 15% for aortic HG and 20 ± 9% for xenografts (log rank P right ventricular outflow tract conduit in young children. However, when a small pulmonary HG is unavailable, bicuspidalization offers a valid alternative, preferable to xenograft conduits, at mid-term follow-up. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  2. Research Note Pilot survey to assess sample size for herbaceous ...

    African Journals Online (AJOL)

    A pilot survey to determine sub-sample size (number of point observations per plot) for herbaceous species composition assessments, using a wheel-point apparatus applying the nearest-plant method, was conducted. Three plots differing in species composition on the Zululand coastal plain were selected, and on each plot ...

  3. Indium-111 platelet scintigraphy and two-dimensional echocardiography for detection of left ventricular thrombus: influence of clot size and age

    International Nuclear Information System (INIS)

    Seabold, J.E.; Schroeder, E.C.; Conrad, G.R.

    1987-01-01

    Two-dimensional echocardiography and indium-111 platelet scintigraphy were performed on 50 dogs to determine the influence of clot age and size on the detection of experimentally induced left ventricular mural thrombus. Thrombus was induced by apical infarction and injection of a sclerosing agent and thrombin. The animals were classified into four groups according to the time of indium-111 platelet injection after thrombus induction: Group I (17 dogs, 1/2 hour after induction; 3 dogs, before induction), Group II (12 dogs, 24 hours after induction) and Group III (12 dogs, 1 week after induction). In Group IV (six control dogs) apical infarction was produced, but thrombin was not injected; indium-111 platelets were injected 1/2 to 1 hour after infarction. The dogs were studied by indium-111 platelet scintigraphy and by two-dimensional echocardiography 1/2 to 5 hours (Group I) and 1 to 5 and up to 72 hours (Groups II to IV) after platelet administration and before death was induced. Two-dimensional echocardiography showed the best overall sensitivity for detection of acute thrombus (97%; 29 of 30). The sensitivity of indium-111 platelet scintigraphy was 86% (18 of 21) for clots greater than or equal to 0.08 ml in size, and 67% (20 of 30) for detection of all clots. Thrombus did not form in 14 dogs of Groups I to III and in 6 of 6 control dogs. The specificity of scintigraphy was 100% (20 of 20) compared with 80% (16 of 20) for echocardiography. Echocardiography was more sensitive than scintigraphy for detecting very small clots in this experimental model

  4. Comparison of gated radionuclide scans and chest radiographs. Assessment of left ventricular impairment in patients with coronary disease.

    Science.gov (United States)

    Bianco, J A; Reinke, D B; Makey, D G; Shafer, R B

    1980-03-01

    Diagnostic efficacy of gated cardiac blood pool imaging was studied in 41 consecutive patients with LV ejection fractions (LVEF) less than or equal to 0.50. Eighty percent of patients were receiving therapy for LV failure at the time of the study. All patients had documented coronary-artery disease (CAD). Chest x-ray films were interpreted blindly by a senior radiologist. Cardiothoracic ratio of less than or equal to 0.50 was recorded as normal. Radionuclide assessment of LV function contributes importantly to the diagnostic and screening value of chest x-ray films. Patients with coronary disease and clinical evidence of heart failure should have radioisotopic studies even if chest x-ray film findings are normal. In patients with coronary artery disease and enlarged LV on chest films, radionuclide study of left ventricular performance aids in defining LV impairment, and in the prognostication of subsequent clinical course.

  5. Assessment of left ventricular mass in sequential studies with cine MR imaging

    International Nuclear Information System (INIS)

    Tomei, E.; Semelka, R.; Wagner, S.; Mayo, J.; Chatterjee, K.; Parmley, W.W.; O'Sullivan, M.; Wolfe, C.L.; Caputo, G.; Higgins, C.B.

    1989-01-01

    The aim of this study was to measure left ventricular (LV) mass in 11 healthy volunteers, 10 patients with dilated cardiomyopathy, and eight patients with LV hypertrophy (LVH), using two sequential studies to compare the characteristics of LV mass in the same subject and in different clinical situations. All subjects underwent short- axis cine MR imaging at 1.5 T. Each subject had two separate studies: the healthy volunteers within 6 months and those with cardiac disease within 1 week. Measurements (both end- systolic and end-diastolic) included LV mass, LV mass index, and wall thickness. LV mass was substantially increased in both DCM and LVH. The interstudy variability for end- systolic and end-diastolic mass was 5.2% and 3.8%, respectively, for healthy volunteers, 5.2% and 4.0% for LVH, and 3.8% and 6.1% for DCM. The low variability indicates the reproducibility of this technique in sequential studies when no change is expected

  6. Assessment of left ventricular performance by ECG-gated SPECT. Comparison with magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tadamura, Eiji; Inubushi, Masayuki; Kubo, Shigeto; Matsumoto, Keiichi; Yokoyama, Hiroshi; Fujita, Toru; Konishi, Junji [Kyoto Univ. (Japan). Faculty of Medicine

    1999-10-01

    In the measurement of a left ventricular volume, MIBI-QGS was compared with MRI. Because it became clear by the experiment using phantom that a volume calculated with QGS was smaller than the actual volume, data of clinical study were corrected. Subjects were 20 patients with coronary artery disease. Fourteen patients had anamnesis of myocardial infarct. ECG-gated SPECT was performed one hour after intravenous injection of MIBI (600 MBq) in rest. End diastolic volume (EDV), end systolic volume (ESV) and ejection fraction (EF) were calculated using QGS. Cine-MR image was obtained by using MR system of 1.5 Tesla within 1 week after SPECT. A condition was as follows; segmented k-space gradient echo with view sharing, TR=11 ms, TE=1.4 ms, flip angle 20 degree, field of view 32 cm, matrix 256 x 196, 8 lines per segment. LVEF, ESV and EF were analysed by Bland-Altman method, and the difference between MIBI-gated-SPECT and MRI was no problem. Horizontal dislocation image and vertical major axis dislocation image were provided. Minor axis crossing images of 10-12 slice were also filmed in order to cover all left ventricles. As a result, availability of MIBI-QGS became clear. Some factors which produces the measurement error are examined. (K.H.)

  7. Three-dimensional speckle tracking imaging assessment of left ventricular change in patient with coronary heart disease and its correlation with serum indexes

    Directory of Open Access Journals (Sweden)

    Jian-Li Fu

    2016-10-01

    Full Text Available Objective: To analyze the three-dimensional speckle tracking imaging assessment of left ventricular change in patient with coronary heart disease and its correlation with serum indexes. Methods: A total of 152 patients first diagnosed with coronary heart disease were the observation group of the study and 117 healthy subjects were the control group. Threedimensional speckle tracking imaging (3D-STI was used to evaluate the left ventricular function parameters of two groups, the serum content of endothelial function indexes and platelet function indexes were detected, and the correlation between left ventricular function parameters under 3D-STI and serum indexes was further analyzed. Results: Absolute values of left ventricular function parameters LVGLS, LVGRS, LVGCS and LVGAS from 3D-STI of observation group were significantly less than those of control group while Ptw and Torsion levels were greater than those of control group; endothelial function indexes vWF, sICAM-1, sVCAM-1 and ET-1 content in serum were significantly higher than those of control group while vWF-cp and NO content were significantly lower than those of control group; platelet function indexes CD62P, GMP-140, CD63, sP-selectin, sCD40L and PAC-1 content in serum were significantly higher than those of control group. The levels of left ventricular function parameters from 3D-STI in patients with coronary heart disease were directly correlated with serum indexes. Conclusion: 3D-STI can accurately assess the left ventricular function and the overall disease severity in patients with coronary heart disease, and it is expected to become an effective method for early diagnosis of diseases and guidance of clinical treatment.

  8. Significance assessment of small-medium sized reactors

    Energy Technology Data Exchange (ETDEWEB)

    Kanno, Minoru [Japan Atomic Power Co., Research and Development Dept., Tokyo (Japan)

    2002-12-01

    Preliminary assessment for deployment of small-medium sized reactor (S and M reactor) as a future option has been conducted at the JAPCO (Japan Atomic Power Company) under the cooperation with the CRIERI (Central Research Institute of Electric Power Industry). Significance of the S and M reactor introduction is listed as follows; lower investment cost, possible siting near demand side, enlarged freedom of siting, shorter transmission line, good compatibility with slow increase of demand and plain explanation of safety using simpler system such as integral type vessel without piping, natural convection core cooling and passive safety system. The deployment of simpler plant system, modular shop fabrication, ship-shell structured building and longer operation period can assure economics comparable with that of a large sized reactor, coping with scale-demerit. Also the S and M reactor is preferable in size for the nuclear heat utilization such as hydrogen production. (T. Tanaka)

  9. Sample size determination for equivalence assessment with multiple endpoints.

    Science.gov (United States)

    Sun, Anna; Dong, Xiaoyu; Tsong, Yi

    2014-01-01

    Equivalence assessment between a reference and test treatment is often conducted by two one-sided tests (TOST). The corresponding power function and sample size determination can be derived from a joint distribution of the sample mean and sample variance. When an equivalence trial is designed with multiple endpoints, it often involves several sets of two one-sided tests. A naive approach for sample size determination in this case would select the largest sample size required for each endpoint. However, such a method ignores the correlation among endpoints. With the objective to reject all endpoints and when the endpoints are uncorrelated, the power function is the production of all power functions for individual endpoints. With correlated endpoints, the sample size and power should be adjusted for such a correlation. In this article, we propose the exact power function for the equivalence test with multiple endpoints adjusted for correlation under both crossover and parallel designs. We further discuss the differences in sample size for the naive method without and with correlation adjusted methods and illustrate with an in vivo bioequivalence crossover study with area under the curve (AUC) and maximum concentration (Cmax) as the two endpoints.

  10. Diffuse interstitial fibrosis assessed by cardiac magnetic resonance is associated with dispersion of ventricular repolarization in patients with hypertrophic cardiomyopathy

    Directory of Open Access Journals (Sweden)

    David Hurtado-de-Mendoza, MD

    2017-06-01

    Conclusion: Diffuse interstitial fibrosis is associated with increased dispersion of ventricular repolarization in leads, reflecting electrical activity in the hypertrophied septum. Interstitial fibrosis combined with ion channel/gap junction remodeling in the septum could lead to inhomogeneity of ventricular refractoriness, resulting in increased QTc dispersion in leads V1–V4.

  11. Radionuclide assessment of left ventricular function in patients requiring intraoperative balloon pump assistance

    International Nuclear Information System (INIS)

    Davies, R.A.; Laks, H.; Wackers, F.J.; Berger, H.J.; Williams, B.; Hammond, G.L.; Geha, A.S.; Gottschalk, A.; Zaret, B.L.

    1982-01-01

    Twenty-three surviving patients who were weaned from cardiopulmonary bypass with intraaortic balloon pump assistance returned for follow-up radionuclide left ventricular (LV) function and thallium 201 perfusion studies at a mean of 23 +/- 3 months following operation. It was found that despite profound intraoperative myocardial depression requiring intraaortic balloon assistance, 13 patients had no change (within 10%) in the resting LV ejection fraction compared with the preoperative measurement. Among all 23 patients, there was no difference between mean (+/- standard error of the mean) preoperative and postoperative resting LV ejection fraction (48 +/- 4 vs 46 +/- 4%, p . not significant [NS]). Only 11 patients had perioperative myocardial infarction documented by new Q waves in the electrocardiogram, by elevation of creatine kinase-MB fraction, or by defects on thallium 201 imaging not explained by documented myocardial infarction before operation. Overall, postoperative resting LV ejection fraction was not different from the preoperative value in patients with perioperative myocardial infarction (44 +/- 7 vs 47 +/- 5%, p . NS). Postoperative resting LV ejection fraction rose by greater than 10% compared with preoperative values in 4 patients (3 with aortic valve replacement), remained within the 10% limit in 9 patients, and fell by greater than 10% in 10 patients (7 with perioperative myocardial infarction). Only 4 out of 16 patients studied at follow-up with exercise radionuclide studies demonstrated a normal LV response to exercise (greater than 5% increase in LV ejection fraction). Thus, among survivors requiring intraaortic balloon pump assistance for weaning from cardiopulmonary bypass, LV performance at rest is frequently preserved. In addition, 11 of the 23 patients had evidence of perioperative myocardial infarction, indicating a component of reversible intraoperative LV dysfunction

  12. Assessment of poststress left ventricular ejection fraction by gated SPECT: comparison with equilibrium radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Acampa, Wanda; Liuzzi, Raffaele; De Luca, Serena; Capasso, Enza; Luongo, Luca; Cuocolo, Alberto; Caprio, Maria Grazia; Nicolai, Emanuele; Petretta, Mario

    2010-01-01

    We compared left ventricular (LV) ejection fraction obtained by gated SPECT with that obtained by equilibrium radionuclide angiocardiography in a large cohort of patients. Within 1 week, 514 subjects with suspected or known coronary artery disease underwent same-day stress-rest 99m Tc-sestamibi gated SPECT and radionuclide angiocardiography. For both studies, data were acquired 30 min after completion of exercise and after 3 h rest. In the overall study population, a good correlation between ejection fraction measured by gated SPECT and by radionuclide angiocardiography was observed at rest (r=0.82, p<0.0001) and after stress (r=0.83, p<0.0001). In Bland-Altman analysis, the mean differences in ejection fraction (radionuclide angiocardiography minus gated SPECT) were -0.6% at rest and 1.7% after stress. In subjects with normal perfusion (n=362), a good correlation between ejection fraction measured by gated SPECT and by radionuclide angiocardiography was observed at rest (r=0.72, p<0.0001) and after stress (r=0.70, p<0.0001) and the mean differences in ejection fraction were -0.9% at rest and 1.4% after stress. Also in patients with abnormal perfusion (n=152), a good correlation between the two techniques was observed both at rest (r=0.89, p<0.0001) and after stress (r=0.90, p<0.0001) and the mean differences in ejection fraction were 0.1% at rest and 2.5% after stress. In a large study population, a good agreement was observed in the evaluation of LV ejection fraction between gated SPECT and radionuclide angiocardiography. However, in patients with perfusion abnormalities, a slight underestimation in poststress LV ejection fraction was observed using gated SPECT as compared to equilibrium radionuclide angiocardiography. (orig.)

  13. Speckle-tracking strain assessment of left ventricular dysfunction in synthetic cannabinoid and heroin users.

    Science.gov (United States)

    Demirkıran, Aykut; Albayrak, Neslihan; Albayrak, Yakup; Zorkun, Cafer Sadık

    2018-06-01

    There is growing evidence regarding the numerous adverse effects of synthetic cannabinoids (SCBs) on the cardiovascular system; however, no studies have shown the cardiovascular effects of opioids using strain echocardiography. This study examines the cardiac structure and function using echocardiographic strain imaging in heroin and synthetic cannabinoid users. This double-blind study included patients who were admitted or referred to a rehabilitation center for heroin (n=31) and synthetic cannabinoid users (n=30). Heroin users and synthetic cannabinoid users were compared with healthy volunteers (n=32) using two-dimensional (2D) speckle-tracking (ST) echocardiography. No differences were found in the baseline characteristics and 2D echocardiography values. The mean global longitudinal strain value was -20.5%±2.4% for SCB users, -22.3%±2.4% for opioid users, and -22.5%±2.2% for healthy volunteers (p=0.024). The mean apical 2-chamber (AP2C) L-strain values were -20.1%±3.1%, -22.4%±3.0%, and -22.3%±2.8% for SCB users, opioid users, and healthy volunteers, respectively (p=0.032). The mean apical 4-chamber (AP4C) L-strain values were -20.7%±2.5% for SCB users, -23.2%±3.2% for opioid users, and -23.8%±3.1% for healthy volunteers (p<0.001). SCBs are potential causes of subclinical left ventricular dysfunction.

  14. Assessment of global and regional left ventricular function using 64-slice multislice computed tomography and 2D echocardiography: A comparison with cardiac magnetic resonance

    International Nuclear Information System (INIS)

    Annuar, Bin Rapaee; Liew, Chee Khoon; Chin, Sze Piaw; Ong, Tiong Kiam; Seyfarth, M. Tobias; Chan, Wei Ling; Fong, Yean Yip; Ang, Choon Kiat; Lin, Naing; Liew, Houng Bang; Sim, Kui Hian

    2008-01-01

    Objectives: To compare the assessment of global and regional left ventricular (LV) function using 64-slice multislice computed tomography (MSCT), 2D echocardiography (2DE) and cardiac magnetic resonance (CMR). Methods: Thirty-two consecutive patients (mean age, 56.5 ± 9.7 years) referred for evaluation of coronary artery using 64-slice MSCT also underwent 2DE and CMR within 48 h. The global left ventricular function which include left ventricular ejection fraction (LVEF), left ventricular end diastolic volume (LVdV) and left ventricular end systolic volume (LVsV) were determine using the three modalities. Regional wall motion (RWM) was assessed visually in all three modalities. The CMR served as the gold standard for the comparison between 64-slice MSCT with CMR and 2DE with CMR. Statistical analysis included Pearson correlation coefficient, Bland-Altman plots and κ-statistics. Results: The 64-slice MSCT agreed well with CMR for assessment of LVEF (r = 0.92; p < 0.0001), LVdV (r = 0.98; p < 0.0001) and LVsV (r = 0.98; p < 0.0001). In comparison with 64-slice MSCT, 2DE showed moderate correlation with CMR for the assessment of LVEF (r = 0.84; p < 0.0001), LVdV (r = 0.83; p < 0.0001) and LVsV (r = 0.80; p < 0.0001). However in RWM analysis, 2DE showed better accuracy than 64-slice MSCT (94.3% versus 82.4%) and closer agreement (κ = 0.89 versus 0.63) with CMR. Conclusion: 64-Slice MSCT correlates strongly with CMR in global LV function however in regional LV function 2DE showed better agreement with CMR than 64-slice MSCT

  15. Assessment of global and regional left ventricular function using 64-slice multislice computed tomography and 2D echocardiography: A comparison with cardiac magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Annuar, Bin Rapaee [Faculty of Medicine, University Malaysia Sarawak (Malaysia); Department of Cardiology, Sarawak General Hospital (Malaysia)], E-mail: rannuar@fmhs.unimas.my; Liew, Chee Khoon; Chin, Sze Piaw; Ong, Tiong Kiam [Department of Cardiology, Sarawak General Hospital (Malaysia); Seyfarth, M. Tobias [Sieman Medical Solution (Germany); Chan, Wei Ling; Fong, Yean Yip; Ang, Choon Kiat [Department of Cardiology, Sarawak General Hospital (Malaysia); Lin, Naing [Universiti Sains Malaysia (Malaysia); Liew, Houng Bang; Sim, Kui Hian [Department of Cardiology, Sarawak General Hospital (Malaysia)

    2008-01-15

    Objectives: To compare the assessment of global and regional left ventricular (LV) function using 64-slice multislice computed tomography (MSCT), 2D echocardiography (2DE) and cardiac magnetic resonance (CMR). Methods: Thirty-two consecutive patients (mean age, 56.5 {+-} 9.7 years) referred for evaluation of coronary artery using 64-slice MSCT also underwent 2DE and CMR within 48 h. The global left ventricular function which include left ventricular ejection fraction (LVEF), left ventricular end diastolic volume (LVdV) and left ventricular end systolic volume (LVsV) were determine using the three modalities. Regional wall motion (RWM) was assessed visually in all three modalities. The CMR served as the gold standard for the comparison between 64-slice MSCT with CMR and 2DE with CMR. Statistical analysis included Pearson correlation coefficient, Bland-Altman plots and {kappa}-statistics. Results: The 64-slice MSCT agreed well with CMR for assessment of LVEF (r = 0.92; p < 0.0001), LVdV (r = 0.98; p < 0.0001) and LVsV (r = 0.98; p < 0.0001). In comparison with 64-slice MSCT, 2DE showed moderate correlation with CMR for the assessment of LVEF (r = 0.84; p < 0.0001), LVdV (r = 0.83; p < 0.0001) and LVsV (r = 0.80; p < 0.0001). However in RWM analysis, 2DE showed better accuracy than 64-slice MSCT (94.3% versus 82.4%) and closer agreement ({kappa} = 0.89 versus 0.63) with CMR. Conclusion: 64-Slice MSCT correlates strongly with CMR in global LV function however in regional LV function 2DE showed better agreement with CMR than 64-slice MSCT.

  16. Assessment of global and regional left ventricular function using 64-slice multislice computed tomography and 2D echocardiography: a comparison with cardiac magnetic resonance.

    Science.gov (United States)

    Annuar, Bin Rapaee; Liew, Chee Khoon; Chin, Sze Piaw; Ong, Tiong Kiam; Seyfarth, M Tobias; Chan, Wei Ling; Fong, Yean Yip; Ang, Choon Kiat; Lin, Naing; Liew, Houng Bang; Sim, Kui Hian

    2008-01-01

    To compare the assessment of global and regional left ventricular (LV) function using 64-slice multislice computed tomography (MSCT), 2D echocardiography (2DE) and cardiac magnetic resonance (CMR). Thirty-two consecutive patients (mean age, 56.5+/-9.7 years) referred for evaluation of coronary artery using 64-slice MSCT also underwent 2DE and CMR within 48h. The global left ventricular function which include left ventricular ejection fraction (LVEF), left ventricular end diastolic volume (LVdV) and left ventricular end systolic volume (LVsV) were determine using the three modalities. Regional wall motion (RWM) was assessed visually in all three modalities. The CMR served as the gold standard for the comparison between 64-slice MSCT with CMR and 2DE with CMR. Statistical analysis included Pearson correlation coefficient, Bland-Altman plots and kappa-statistics. The 64-slice MSCT agreed well with CMR for assessment of LVEF (r=0.92; p<0.0001), LVdV (r=0.98; p<0.0001) and LVsV (r=0.98; p<0.0001). In comparison with 64-slice MSCT, 2DE showed moderate correlation with CMR for the assessment of LVEF (r=0.84; p<0.0001), LVdV (r=0.83; p<0.0001) and LVsV (r=0.80; p<0.0001). However in RWM analysis, 2DE showed better accuracy than 64-slice MSCT (94.3% versus 82.4%) and closer agreement (kappa=0.89 versus 0.63) with CMR. 64-Slice MSCT correlates strongly with CMR in global LV function however in regional LV function 2DE showed better agreement with CMR than 64-slice MSCT.

  17. Serial assessment of left ventricular function in various patient groups with Tl-201 gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Wei Lingge; Kadoya, Masumi; Momose, Mitsuhiro; Kurozumi, Masahiro; Matsushita, Tsuyoshi; Yamada, Akira

    2007-01-01

    The present study was performed to assess stress-related left ventricular (LV) function variations in various patient groups and to determine if they were affected by sex or the type of stress experienced. We used thallium (Tl)-201 gated myocardial perfusion single-photon emission computed tomography (SPECT) for the analysis. A total of 270 patients were examined by electrocardiography-gated myocardial perfusion SPECT imaging to assess LV function. After injection of Tl-201 at a dose of 111 MBq at peak stress, SPECT scans were acquired at 10 min (after stress) and 3 h (rest) after injection on a three-headed camera. In the normal perfusion group, the mean LV ejection fraction (LVEF) was significantly higher, and both the end-diastolic volume index (EDVI) and end-systolic volume index (ESVI) were significantly lower in women than in men (P<0.05). Poststress stunning occurred in 29 of 98 patients (30.0%) in the ischemia group and in 42 of 90 patients (46.7%) in the fixed group. There was a significant difference in poststress stunning between bicycle ergometer stress and dipyridamole stress (P<0.05). In patients with normal perfusion, LVEF, EDVI, and ESVI determined by gated Tl-201 SPECT should be corrected for sex. In addition, the influence of the type of stress should be considered when assessing stress-related LV function variations. (author)

  18. Left ventricular long axis function assessed during cine-cardiovascular magnetic resonance is an independent predictor of adverse cardiac events.

    Science.gov (United States)

    Rangarajan, Vibhav; Chacko, Satish Jacob; Romano, Simone; Jue, Jennifer; Jariwala, Nikhil; Chung, Jaehoon; Farzaneh-Far, Afshin

    2016-06-07

    Left ventricular pump function requires a complex interplay involving myocardial fibers orientated in the longitudinal, oblique and circumferential directions. Long axis dysfunction appears to be an early marker for a number of pathological states. We hypothesized that mitral annular plane systolic excursion (MAPSE) measured during cine-cardiovascular magnetic resonance (CMR) reflects changes in long axis function and may be an early marker for adverse cardiovascular outcomes. The aims of this study were therefore: 1) To assess the feasibility and reproducibility of MAPSE measurements during routine cine-CMR; and 2) To assess whether MAPSE, as a surrogate for long axis function, is a predictor of major adverse cardiovascular events (MACE). Four hundred consecutive patients undergoing CMR were prospectively enrolled. MAPSE was measured in the 4-chamber cine view. Patients were prospectively followed for major adverse cardiac events (MACE) - death, non-fatal myocardial infarction, hospitalization for heart failure or unstable angina, and late revascularization. Cox proportional hazards regression modeling was used to identify factors independently associated with MACE. Net reclassification improvement (NRI) was calculated to assess whether addition of MAPSE resulted in improved risk reclassification of MACE. Seventy-two MACE occurred during a median follow-up of 14.5 months. By Kaplan-Meier analysis, patients with lateral MAPSE cine-CMR is an independent predictor of MACE.

  19. Heart rate index: an indicator of left ventricular ejection fraction. Comparison of left ventricular ejection fraction and variables assessed by exercise test in patients studied early after acute myocardial infarction

    DEFF Research Database (Denmark)

    Haedersdal, C; Pedersen, F H; Svendsen, Jesper Hastrup

    1992-01-01

    The present study compares the variables assessed by standard exercise test with the left ventricular ejection fraction (LVEF) measured by multigated radionuclide angiocardiography (MUGA) in 77 patients early after myocardial infarction. The exercise test and MUGA were performed within two weeks...... at rest, 4) rise in systolic blood pressure, 5) rate pressure product at rest, 6) rise in rate pressure product, 7) ratio (rHR) between maximal rate pressure product and rate pressure product at rest, 8) total exercise time. The heart rate was corrected for effects caused by age (heart index (HR...

  20. Effects of antithrombotic drugs in patients with left ventricular thrombi: assessment with indium-111 platelet imaging and two-dimensional echocardiography

    International Nuclear Information System (INIS)

    Stratton, J.R.; Ritchie, J.L.

    1984-01-01

    Patients with left ventricular thrombi not caused by recent myocardial infarction were prospectively studied by indium-111 platelet imaging and two-dimensional echocardiography to determine the reproducibility of these techniques and the short-term effects of sulfinpyrazone (200 mg four times daily), aspirin (325 mg three times daily) plus dipyridamole (75 mg three times daily), and full-dose warfarin. At baseline, all patients underwent indium-111 platelet imaging and echocardiography, and the results were positive for thrombus. In six patients on no antithrombotic drug therapy, repeat platelet scans and echocardiographic studies at 6.0 +/- 3.3 weeks remained positive and were unchanged. In seven patients studied on sulfinpyrazone, three platelet scans became negative, two became equivocal, and two were unchanged; the presence and size of thrombus was constant by echocardiography in all seven patients. Of the six patients studied on aspirin plus dipyridamole, one platelet scan became negative, those of three became equivocal, and two were unchanged; all echocardiographic findings remained positive, but one patient had decreased thrombus size. Among four warfarin-treated patients, three had resolution of platelet deposition and one was unchanged; by echocardiography, thrombus resolved in one patient, was decreased in size in one, and was unchanged in two. We conclude that, in the absence of antithrombotic drug therapy, platelet imaging and echocardiographic findings are stable in patients with left ventricular thrombi not caused by recent myocardial infarction. Sulfinpyrazone, aspirin plus dipyridamole, and warfarin all interrupt platelet deposition in some patients with chronic left ventricular thrombi

  1. Feasibility of free-breathing, GRAPPA-based, real-time cardiac cine assessment of left-ventricular function in cardiovascular patients at 3T.

    Science.gov (United States)

    Zhu, Xiaomei; Schwab, Felix; Marcus, Roy; Hetterich, Holger; Theisen, Daniel; Kramer, Harald; Notohamiprodjo, Mike; Schlett, Christopher L; Nikolaou, Konstantin; Reiser, Maximilian F; Bamberg, Fabian

    2015-05-01

    To determine the feasibility of free-breathing, GRAPPA-based, real-time (RT) cine 3T cardiac magnetic resonance imaging (MRI) with high acceleration factors for the assessment of left-ventricular function in a cohort of patients as compared to conventional segmented cine imaging. In this prospective cohort study, subjects with various cardiac conditions underwent MRI involving two RT cine sequences (high resolution and low resolution) and standard segmented cine imaging. Standard qualitative and quantitative parameters of left-ventricular function were quantified. Among 25 subjects, 24 were included in the analysis (mean age: 50.5±21 years, 67% male, 25% with cardiomyopathy). RT cine derived quantitative parameters of volumes and left ventricular mass were strongly correlated with segmented cine imaging (intraclass correlation coefficient [ICC]: >0.72 for both RT cines) but correlation for peak ejection and filling rates were moderate to poor for both RT cines (ICCcines significantly underestimated peak ejection and filling rates (>103.2±178 ml/s). Among patient-related factors, heart rate was strongly predictive for deviation of measurements (pcine MRI at 3T is feasible for qualitative and quantitative assessment of left ventricular function for low and high-resolution sequences but results in significant underestimation of systolic function, peak ejection and filling rates. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. Feasibility of free-breathing, GRAPPA-based, real-time cardiac cine assessment of left-ventricular function in cardiovascular patients at 3 T

    International Nuclear Information System (INIS)

    Zhu, Xiaomei; Schwab, Felix; Marcus, Roy; Hetterich, Holger; Theisen, Daniel; Kramer, Harald; Notohamiprodjo, Mike; Schlett, Christopher L.; Nikolaou, Konstantin; Reiser, Maximilian F.

    2015-01-01

    Highlights: • Grappa-based real time cine cardiac MRI is feasible for assessment of left ventricular function. • Significant underestimation of systolic function, peak ejection and filling rates needs to be considered. • Heart rate is the only positive predictor of the deviation of obtained parameters. - Abstract: Objectives: To determine the feasibility of free-breathing, GRAPPA-based, real-time (RT) cine 3 T cardiac magnetic resonance imaging (MRI) with high acceleration factors for the assessment of left-ventricular function in a cohort of patients as compared to conventional segmented cine imaging. Materials and methods: In this prospective cohort study, subjects with various cardiac conditions underwent MRI involving two RT cine sequences (high resolution and low resolution) and standard segmented cine imaging. Standard qualitative and quantitative parameters of left-ventricular function were quantified. Results: Among 25 subjects, 24 were included in the analysis (mean age: 50.5 ± 21 years, 67% male, 25% with cardiomyopathy). RT cine derived quantitative parameters of volumes and left ventricular mass were strongly correlated with segmented cine imaging (intraclass correlation coefficient [ICC]: >0.72 for both RT cines) but correlation for peak ejection and filling rates were moderate to poor for both RT cines (ICC < 0.40). Similarly, RT cines significantly underestimated peak ejection and filling rates (>103.2 ± 178 ml/s). Among patient-related factors, heart rate was strongly predictive for deviation of measurements (p < 0.05). Conclusions: RT cine MRI at 3 T is feasible for qualitative and quantitative assessment of left ventricular function for low and high-resolution sequences but results in significant underestimation of systolic function, peak ejection and filling rates

  3. Assessment of left ventricular regional function in affected and carrier dogs with duchenne muscular dystrophy using speckle tracking echocardiography

    Directory of Open Access Journals (Sweden)

    Yugeta Naoko

    2011-05-01

    Full Text Available Abstract Background Two-dimensional speckle tracking echocardiography (STE is a relatively new method to detect regional myocardial dysfunction. To assess left ventricular (LV regional myocardial dysfunction using STE in Duchenne muscular dystrophy model dogs (CXMDJ without overt clinical signs of heart failure. Methods Six affected dogs, 8 carrier dogs with CXMDJ, and 8 control dogs were used. Conventional echocardiography, systolic and diastolic function by Doppler echocardiography, tissue Doppler imaging (TDI, and strain indices using STE, were assessed and compared among the 3 groups. Results Significant differences were seen in body weight, transmitral E wave and E' wave derived from TDI among the 3 groups. Although no significant difference was observed in any global strain indices, in segmental analysis, the peak radial strain rate during early diastole in posterior segment at chordae the tendineae level showed significant differences among the 3 groups. Conclusions The myocardial strain rate by STE served to detect the impaired cardiac diastolic function in CXMDJ without any obvious LV dilation or clinical signs. The radial strain rate may be a useful parameter to detect early myocardial impairment in CXMDJ.

  4. Computer-based assessment of right ventricular regional ejection fraction in patients with repaired Tetralogy of Fallot

    Science.gov (United States)

    Teo, S.-K.; Wong, S. T.; Tan, M. L.; Su, Y.; Zhong, L.; Tan, Ru-San

    2015-03-01

    After surgical repair for Tetralogy of Fallot (TOF), most patients experience long-term complications as the right ventricle (RV) undergoes progressive remodeling that eventually affect heart functions. Thus, post-repair surgery is required to prevent further deterioration of RV functions that may result in malignant ventricular arrhythmias and mortality. The timing of such post-repair surgery therefore depends crucially on the quantitative assessment of the RV functions. Current clinical indices for such functional assessment measure global properties such as RV volumes and ejection fraction. However, these indices are less than ideal as regional variations and anomalies are obscured. Therefore, we sought to (i) develop a quantitative method to assess RV regional function using regional ejection fraction (REF) based on a 13-segment model, and (ii) evaluate the effectiveness of REF in discriminating 6 repaired TOF patients and 6 normal control based on cardiac magnetic resonance (CMR) imaging. We observed that the REF for the individual segments in the patient group is significantly lower compared to the control group (P < 0.05 using a 2-tail student t-test). In addition, we also observed that the aggregated REF at the basal, mid-cavity and apical regions for the patient group is significantly lower compared to the control group (P < 0.001 using a 2-tail student t-test). The results suggest that REF could potentially be used as a quantitative index for assessing RV regional functions. The computational time per data set is approximately 60 seconds, which demonstrates our method's clinical potential as a real-time cardiac assessment tool.

  5. Interaction of Left Ventricular Size and Sex on Outcome of Cardiac Resynchronization Therapy Among Patients With a Narrow QRS Duration in the EchoCRT Trial

    DEFF Research Database (Denmark)

    Varma, Niraj; Sogaard, Peter; Bax, Jeroen J

    2018-01-01

    BACKGROUND: Longer QRS duration (QRSd) improves, but increased left ventricular (LV) end-diastolic volume (LVEDV) reduces, efficacy of cardiac resynchronization therapy (CRT). QRSd/LVEDV ratios differ between sexes. We hypothesized that in the EchoCRT (Echocardiography Guided Cardiac Resynchroniz......BACKGROUND: Longer QRS duration (QRSd) improves, but increased left ventricular (LV) end-diastolic volume (LVEDV) reduces, efficacy of cardiac resynchronization therapy (CRT). QRSd/LVEDV ratios differ between sexes. We hypothesized that in the EchoCRT (Echocardiography Guided Cardiac...... Resynchronization Therapy) trial enrolling patients with heart failure with QRSd New York Heart Association class III, QRSd

  6. Assessment of left ventricular function with single breath-hold highly accelerated cine MRI combined with guide-point modeling

    International Nuclear Information System (INIS)

    Heilmaier, Christina; Nassenstein, Kai; Nielles-Vallespin, Sonia; Zuehlsdorff, Sven; Hunold, Peter; Barkhausen, Joerg

    2010-01-01

    Purpose: To prospectively assess the performance of highly accelerated cine MRI in multi-orientations combined with a new guide-point modeling post-processing technique (GPM approach) for assessment of left ventricular (LV) function compared to the standard summation of slices method based on a stack of short axis views (SoS approach). Materials and methods: 33 consecutive patients were examined on a 1.5 T scanner with a standard steady state free precession (SSFP) sequence (TR, 3.0 ms; TE, 1.5 m; flip angle (FA), 60 o ; acceleration factor (AF), 2) analyzed with the SoS method and a highly accelerated, single breath-hold temporal parallel acquisition SSFP sequence (TR, 4.6 ms; TE, 1.1 ms; AF, 3) post-processed with the GPM method. LV function values were measured by two independent readers with different experience in cardiac MRI and compared by using the paired t-test and F-test. Inter- and intraobserver agreements were calculated using Bland-Altman-Plots. Results: Mean acquisition and post-processing time was significantly shorter with the GPM approach (15 s/3 min versus 360 s/6 min). For all LV function parameters interobserver agreement between the experienced and non-experienced reader was significantly improved when the GPM approach was used. However, end-diastolic and end-systolic volumes were larger for the GPM technique when compared to the SoS method (P 0.121). In both readers and for all parameters variances did not differ significantly (P ≥ 0.409) and the two approaches showed an excellent linear correlation (r > 0.951). Conclusion: Due to its accurate, fast and reproducible assessment of LV function parameters highly accelerated MRI combined with the GPM technique may become the technique of first choice for assessment of LV function in clinical routine.

  7. Left ventricular hypertrophy is associated with increased infarct size and decreased myocardial salvage in patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Nepper-Christensen, Lars; Lønborg, Jacob; Ahtarovski, Kiril Aleksov

    2017-01-01

    Background--Approximately one third of patients with ST-segment elevation myocardial infarction (STEMI) have left ventricular hypertrophy (LVH), which is associated with impaired outcome. However, the causal association between LVH and outcome in STEMI is unknown. We evaluated the association bet...

  8. Mechanisms of Left Ventricular Dysfunction Assessed by Layer-Specific Strain Analysis in Patients With Repaired Tetralogy of Fallot.

    Science.gov (United States)

    Yamada, Mariko; Takahashi, Ken; Kobayashi, Maki; Yazaki, Kana; Takayasu, Hirobumi; Akimoto, Katsumi; Kishiro, Masahiko; Inage, Akio; Yoshikawa, Tadahiro; Park, In-Sam; Nakanishi, Keisuke; Kawasaki, Shiori; Shimizu, Toshiaki

    2017-05-25

    Left ventricular (LV) dysfunction in patients with repaired tetralogy of Fallot (rTOF) is an important risk factor for adverse outcomes. The aim of this study was to assess the details and time course of such LV dysfunction using layer-specific strain analysis by echocardiography.Methods and Results:The 66 patients with rTOF (mean age, 16.3±9.3 years) were divided into 3 groups (T1: 4-10 years, T2: 11-20 years, T3: 21-43 years), and 113 controls of similar age (mean age, 17.2±9.3 years) were divided into 3 corresponding groups (C1, C2, and C3). Layer-specific longitudinal strain (LS) and circumferential strain (CS) of 3 myocardial layers (endocardial, midmyocardial, and epicardial) were determined by echocardiography. Basal and papillary endocardial CS values were decreased in T1 compared with C1. With the exception of papillary epicardial CS, basal/papillary CS and LS of all 3 layers decreased in T2 compared with C2. Excepting papillary epicardial CS, all other values were decreased in T3 compared with C3. Potential myocardial damage was found in the endocardium at the basal and papillary levels of the LV in young patients with rTOF, extending from the endocardium to the epicardium and from the base to the apex. This is the possible time course of LV dysfunction in patients with rTOF.

  9. Assessment of Left Ventricular Function and Mass on Free-Breathing Compressed Sensing Real-Time Cine Imaging.

    Science.gov (United States)

    Kido, Tomoyuki; Kido, Teruhito; Nakamura, Masashi; Watanabe, Kouki; Schmidt, Michaela; Forman, Christoph; Mochizuki, Teruhito

    2017-09-25

    Compressed sensing (CS) cine magnetic resonance imaging (MRI) has the advantage of being inherently insensitive to respiratory motion. This study compared the accuracy of free-breathing (FB) CS and breath-hold (BH) standard cine MRI for left ventricular (LV) volume assessment.Methods and Results:Sixty-three patients underwent cine MRI with both techniques. Both types of images were acquired in stacks of 8 short-axis slices (temporal/spatial resolution, 41 ms/1.7×1.7×6 mm 3 ) and compared for ejection fraction, end-diastolic and systolic volumes, stroke volume, and LV mass. Both BH standard and FB CS cine MRI provided acceptable image quality for LV volumetric analysis (score ≥3) in all patients (4.7±0.5 and 3.7±0.5, respectively; Pcine MRI (median, IQR: BH standard, 83.8 mL, 64.7-102.7 mL; FB CS, 79.0 mL, 66.0-101.0 mL; P=0.0006). The total acquisition times for BH standard and FB CS cine MRI were 113±7 s and 24±4 s, respectively (Pcine MRI is a clinically useful alternative to BH standard cine MRI in patients with impaired BH capacity.

  10. Experimental assessment of valve performance in healthy and diseased right ventricular outflow tracts using magnetic resonance velocimetry

    Science.gov (United States)

    Schiavone, Nicole; Elkins, Christopher; McElhinney, Doff; Eaton, John K.; Marsden, Alison

    2017-11-01

    Tetralogy of Fallot (ToF), the most common type of cyanotic congenital heart defect, affects 1 in every 2500 newborns annually and typically requires surgical repair of the right ventricular outflow tract (RVOT) and placement of an artificial pulmonary valve. All artificial valves are subject to dysfunction, but their longevity is highly variable. Clinical observation reveals large variations in RVOT anatomy in ToF patients, which may affect longevity. This work aims to experimentally assess the performance of artificial pulmonary valves in anatomically realistic healthy and diseased RVOT geometries using magnetic resonance velocimetry (MRV). With MRV, we can capture 3D, three-component, phase-averaged velocity fields in 3D printed RVOT geometries. The experiment is designed to ensure physiological flow rate and pressure waveforms, while the RVOT geometries are based on anatomies seen clinically in ToF patients. Two models are used in the current work: an idealized RVOT based on healthy subjects aged eleven to thirteen and a diseased geometry with a dilation of 150% in vessel diameter downstream of the pulmonary valve. We will also present preliminary rigid-wall blood flow simulations in each model, towards the ultimate goal of experimental validation of valve simulations.

  11. Clinical evaluation of 64-slice CT assessment of global left ventricular function using automated cardiac phase selection

    International Nuclear Information System (INIS)

    Joemai, Raoul M.S.; Geleijns, Joemai; Veldkamp, Wouter J.H.; Kroft, Lucia J.M.

    2008-01-01

    Left ventricular (LV) function provides prognostic information regarding the morbidity and mortality of patients. An automated cardiac phase selection algorithm has the potential to support the assessment of LV function with computed tomography (CT). This algorithm is clinically evaluated for 64-slice cardiac CT. Examinations of twenty consecutive patients were selected. Electrocardiogram gated contrast-enhanced CT was performed. Reconstructions were performed using an automated and a manual method, followed by the determination of the global LV function. Significances were tested using 2-sided Student's t-tests. Reduction in post processing time and storage capacity were estimated. A slightly smaller mean end-systolic volume was found with the automated method (52±18 ml vs 54±17 ml, p=0.02, r=0.99). The mean LV ejection fraction was slightly larger with the automated method (65±8% vs 64±8%, p=0.004, r=0.99). The estimated reduction in post processing time was maximal 5 min per patient with a potential 80% data storage reduction. Results of the automated phase selection algorithm are similar to the manual method. The automated tool reduces post processing time, reconstruction time and transfer time. (author)

  12. Performance of Thallium-201 Electrocardiography-gated Myocardial Perfusion Single Photon Emission Computed Tomography to Assess Left Ventricular Function

    Directory of Open Access Journals (Sweden)

    Guang-Uei Hung

    2005-05-01

    Full Text Available This study evaluated the performance of gated single photon emission computed tomography (SPECT with thallium-201 (201Tl in assessing left ventricular ejection fraction (LVEF, end-diastolic volume (EDV, and end-systolic volume (ESV in Taiwanese by determining repeatability and correlation with two-dimensional (2D echocardiography. A total of 18 patients underwent two sequential gated SPECT acquisitions within 30 minutes in the resting state to assess repeatability. Another 28 patients who underwent gated SPECT and 2D echocardiography within 7 days were included for comparison. The two sequential measurements were well correlated with respect to LVEF, EDV, and ESV (r = 0.97, 0.95, and 0.97, respectively, all p < 0.0001. Bland-Altman analysis revealed that two standard deviations of the absolute difference between the two sequential measurements for LVEF, EDV, and ESV were 6.4%, 16.8 mL, and 8.6 mL, respectively. For LVEF, EDV, and ESV, correlations between redistribution 201Tl-gated SPECT and echocardiography were also excellent (all r = 0.83, p < 0.0001. LVEF was similar with 201Tl-gated SPECT and echocardiography, but EDV and ESV were significantly higher with echocardiography (p < 0.05. Our study revealed that 201Tl-gated SPECT has high repeatability and excellent correlation with echocardiography for the assessment of LVEF and volumes in Taiwanese. These results support the clinical application of gated SPECT in routine 201Tl myocardial perfusion imaging in Taiwanese.

  13. Assessment of vasodilator therapy in patients with severe congestive heart failure: limitations of measurements of left ventricular ejection fraction and volumes

    International Nuclear Information System (INIS)

    Firth, B.G.; Dehmer, G.J.; Markham, R.V. Jr.; Willerson, J.T.; Hillis, L.D.

    1982-01-01

    Although noninvasive techniques are often used to assess the effect of vasodilator therapy in patients with congestive heart failure, it is unknown whether changes in noninvasively determined left ventricular ejection fraction, volume, or dimension reliably reflect alterations in intracardiac pressure and flow. Accordingly, we compared the acute effect of sodium nitroprusside on left ventricular volume and ejection fraction (determined scintigraphically) with its effect on intracardiac pressure and forward cardiac index (determined by thermodilution) in 12 patients with severe, chronic congestive heart failure and a markedly dilated left ventricle. Nitroprusside (infused at 1.3 +/- 1.1 [mean +/- standard deviation] microgram/kg/min) caused a decrease in mean systemic arterial, mean pulmonary arterial, and mean pulmonary capillary wedge pressure as well as a concomitant increase in forward cardiac index. Simultaneously, left ventricular end-diastolic and end-systolic volume indexes decreased, but the scintigraphically determined cardiac index did not change significantly. Left ventricular ejection fraction averaged 0.19 +/- 0.05 before nitroprusside administration and increased by less than 0.05 units in response to nitroprusside in 11 of 12 patients. The only significant correlation between scintigraphically and invasively determined variables was that between the percent change in end-diastolic volume index and the percent change in pulmonary capillary wedge pressure (r . 0.68, p . 0.01). Although nitroprusside produced changes in scintigraphically determined left ventricular ejection fraction, end-systolic volume index, and cardiac index, these alterations bore no predictable relation to changes in intracardiac pressure, forward cardiac index, or vascular resistance. Furthermore, nitroprusside produced a considerably greater percent change in the invasively measured variables than in the scintigraphically determined ones

  14. Brain ventricular wall movement assessed by a gated cine MR trueFISP sequence in patients treated with endoscopic third ventriculostomy

    International Nuclear Information System (INIS)

    Hodel, Jerome; Decq, Philippe; Rahmouni, Alain; Bastuji-Garin, Sylvie; Maraval, Anne; Combes, Catherine; Gaston, Andre; Jarraya, Bechir; Le Guerinel, Caroline

    2009-01-01

    The purpose of this study was to investigate the value of brain ventricular wall movement assessment with a gated cine trueFISP MR sequence for the diagnosis of endoscopic third ventriculostomy (ETV) patency. Sixteen healthy volunteers and ten consecutive patients with noncommunicating hydrocephalus were explored with a MR scanner (Siemens, Avanto 1.5 T) before, 1 week and 3 months after ETV. TrueFISP was evaluated qualitatively (ventricular wall movement and CSF flow through ETV) and quantitatively [distance moved (DMLT) during a cardiac cycle by the lamina terminalis]. The third ventricle volume (TVV) was assessed. Statistical analysis was performed using nonparametric tests. There was no motion of the lamina terminalis (LT) detected on preoperative data. A pulsatile motion of the LT was found for patients with a patent ETV and for controls. DMLT and TVV were correlated (r = 0.79, P = 0.006). A transient dysfunction of ETV was successfully diagnosed on the trueFISP sequence with no motion of the LT or CSF flow observed. The trueFISP sequence appears reliable for the diagnosis of ETV patency and provides non-invasive assessment of the movement of the ventricular wall related to CSF pressure changes. (orig.)

  15. Brain ventricular wall movement assessed by a gated cine MR trueFISP sequence in patients treated with endoscopic third ventriculostomy

    Energy Technology Data Exchange (ETDEWEB)

    Hodel, Jerome [Unite Analyse et Restauration du mouvement, UMR-CNRS, Paris (France); Faculte de Medecine Paris XII, Paris (France); Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Henri MONDOR, Department of Neuroradiology, Creteil (France); Hopital Henri Mondor, Creteil (France); Decq, Philippe [Unite Analyse et Restauration du mouvement, UMR-CNRS, Paris (France); Faculte de Medecine Paris XII, Paris (France); Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Henri MONDOR, Department of Neurosurgery, Creteil (France); Rahmouni, Alain [Faculte de Medecine Paris XII, Paris (France); Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Henri MONDOR, Department of Radiology, Creteil (France); Bastuji-Garin, Sylvie [Faculte de Medecine Paris XII, Paris (France); Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Henri MONDOR, Department of Public Health, Creteil (France); Maraval, Anne; Combes, Catherine; Gaston, Andre [Faculte de Medecine Paris XII, Paris (France); Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Henri MONDOR, Department of Neuroradiology, Creteil (France); Jarraya, Bechir [Faculte de Medecine Paris XII, Paris (France); Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Henri MONDOR, Department of Neurosurgery, Creteil (France); Le Guerinel, Caroline [Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Henri MONDOR, Department of Neurosurgery, Creteil (France)

    2009-12-15

    The purpose of this study was to investigate the value of brain ventricular wall movement assessment with a gated cine trueFISP MR sequence for the diagnosis of endoscopic third ventriculostomy (ETV) patency. Sixteen healthy volunteers and ten consecutive patients with noncommunicating hydrocephalus were explored with a MR scanner (Siemens, Avanto 1.5 T) before, 1 week and 3 months after ETV. TrueFISP was evaluated qualitatively (ventricular wall movement and CSF flow through ETV) and quantitatively [distance moved (DMLT) during a cardiac cycle by the lamina terminalis]. The third ventricle volume (TVV) was assessed. Statistical analysis was performed using nonparametric tests. There was no motion of the lamina terminalis (LT) detected on preoperative data. A pulsatile motion of the LT was found for patients with a patent ETV and for controls. DMLT and TVV were correlated (r = 0.79, P = 0.006). A transient dysfunction of ETV was successfully diagnosed on the trueFISP sequence with no motion of the LT or CSF flow observed. The trueFISP sequence appears reliable for the diagnosis of ETV patency and provides non-invasive assessment of the movement of the ventricular wall related to CSF pressure changes. (orig.)

  16. Assessment of right ventricular function and anatomy using peripheral vein infusion of krypton 81m

    Energy Technology Data Exchange (ETDEWEB)

    Sugrue, D.D.; Kamal, S.; Deanfield, J.E.; McKenna, W.J.; Myers, M.J.; Watson, I.A.; Oakley, C.M.; Lavender, J.P. (Royal Postgraduate Medical School, London (UK))

    1983-09-01

    A method for imaging the right side of the heart (atrium, ventricle and main pulmonary artery) and for assessment of RV systolic function (ejection fraction and ejection rate) is described. An ultra-short-lived isotope (/sup 81/Krsup(m)) is continuously eluted in 5% dextrose and infused into an ante-cubital arm vein; standard multigated images are acquired using a gamma camera and commercially available software. Preliminary evaluation of the method in 55 subjects (20 with repaired tetralogy of Fallot, 14 with dilated cardiomyopathy and 21 normal volunteers) showed that the technical success rate was 100%; that RV boundaries free from LV overlap can be clearly visualised due to efficient exhalation of /sup 81/Krsup(m) through the lungs and that /sup 81/Krsup(m) measurements of RVEF are reproducible. The technique offers considerable potential for serial non-invasive assessment of RV function.

  17. Assessment of right ventricular function and anatomy using peripheral vein infusion of krypton 81m

    International Nuclear Information System (INIS)

    Sugrue, D.D.; Kamal, S.; Deanfield, J.E.; McKenna, W.J.; Myers, M.J.; Watson, I.A.; Oakley, C.M.; Lavender, J.P.

    1983-01-01

    A method for imaging the right side of the heart (atrium, ventricle and main pulmonary artery) and for assessment of RV systolic function (ejection fraction and ejection rate) is described. An ultra-short-lived isotope ( 81 Krsup(m)) is continuously eluted in 5% dextrose and infused into an ante-cubital arm vein; standard multigated images are acquired using a gamma camera and commercially available software. Preliminary evaluation of the method in 55 subjects (20 with repaired tetralogy of Fallot, 14 with dilated cardiomyopathy and 21 normal volunteers) showed that the technical success rate was 100%; that RV boundaries free from LV overlap can be clearly visualised due to efficient exhalation of 81 Krsup(m) through the lungs and that 81 Krsup(m) measurements of RVEF are reproducible. The technique offers considerable potential for serial non-invasive assessment of RV function. (author)

  18. Left ventricular diastolic dyssynchrony assessed with phase analysis of gated myocardial perfusion SPECT: a comparison with tissue Doppler imaging

    International Nuclear Information System (INIS)

    Boogers, Mark J.; Veltman, Caroline E.; Chen, Ji; Garcia, Ernest V.; Bommel, Rutger J. van; Mooyaart, Eline A.Q.; Wall, Ernst E. van der; Schalij, Martin J.; Bax, Jeroen J.; Delgado, Victoria; Younis, Imad Al; Hiel, Bernies van der; Dibbets-Schneider, Petra

    2011-01-01

    The aim of the current study was to evaluate the feasibility of phase analysis on gated myocardial perfusion SPECT (GMPS) for the assessment of left ventricular (LV) diastolic dyssynchrony in a head-to-head comparison with tissue Doppler imaging (TDI). The population consisted of patients with end-stage heart failure of New York Heart Association functional class III or IV with a reduced LV ejection fraction of ≤35%. LV diastolic dyssynchrony was calculated using TDI as the maximal time delay between early peak diastolic velocities of two opposing left ventricle walls (diastolic mechanical delay). Significant LV diastolic dyssynchrony was defined as a diastolic mechanical delay of >55 ms on TDI. Furthermore, phase analysis on GMPS was performed to evaluate LV diastolic dyssynchrony; diastolic phase standard deviation (SD) and histogram bandwidth (HBW) were used as markers of LV diastolic dyssynchrony. A total of 150 patients (114 men, mean age 66.0 ± 10.4 years) with end-stage heart failure were enrolled. Both diastolic phase SD (r = 0.81, p 55 ms) showed significantly larger diastolic phase SD (68.1 ± 13.4 vs. 40.7 ± 14.0 , p < 0.01) and diastolic HBW (230.6 ± 54.3 vs. 129.0 ± 55.6 , p < 0.01) as compared to patients without LV diastolic dyssynchrony on TDI (≤55 ms). Finally, phase analysis on GMPS showed a good intra- and interobserver reproducibility for the determination of diastolic phase SD (ICC 0.97 and 0.88) and diastolic HBW (ICC 0.98 and 0.93). Phase analysis on GMPS showed good correlations with TDI for the assessment of LV diastolic dyssynchrony. (orig.)

  19. Ventricular Assist Device implant (AB 5000 prototype cannula: In vitro assessment of MRI issues at 3-Tesla

    Directory of Open Access Journals (Sweden)

    Valencerina Samuel

    2008-05-01

    Full Text Available Abstract Purpose To evaluate MRI issues at 3-Tesla for a ventricular assist device (VAD. Methods The AB5000 Ventricle with a prototype Nitinol wire-reinforced In-Flow Cannula and Out-Flow Cannula attached (Abiomed, Inc., Danvers, MA was evaluated for magnetic field interactions, heating, and artifacts at 3-Tesla. MRI-related heating was assessed with the device in a gelled-saline-filled, head/torso phantom using a transmit/received RF body coil while performing MRI at a whole body averaged SAR of 3-W/kg for 15-min. Artifacts were assessed for the main metallic component of this VAD (atrial cannula using T1-weighted, spin echo and gradient echo pulse sequences. Results The AB5000 Ventricle with the prototype In-Flow Cannula and Out-Flow Cannula attached showed relatively minor magnetic field interactions that will not cause movement in situ. Heating was not excessive (highest temperature change, +0.8°C. Artifacts may create issues for diagnostic imaging if the area of interest is in the same area or close to the implanted metallic component of this VAD (i.e., the venous cannula. Conclusion The results of this investigation demonstrated that it would be acceptable for a patient with this VAD (AB5000 Ventricle with a prototype Nitinol wire-reinforced In-Flow Cannula and Out-Flow Cannula attached to undergo MRI at 3-Tesla or less. Notably, it is likely that the operation console for this device requires positioning a suitable distance (beyond the 100 Gauss line or in the MR control room from the 3-Tesla MR system to ensure proper function of the VAD.

  20. Strain-encoding cardiovascular magnetic resonance for assessment of right-ventricular regional function

    Directory of Open Access Journals (Sweden)

    Abraham M Roselle

    2008-07-01

    Full Text Available Abstract Background Tissue tagging by cardiovascular magnetic resonance (CMR is a comprehensive method for the assessment of cardiac regional function. However, imaging the right ventricle (RV using this technique is problematic due to the thin wall of the RV relative to tag spacing which limits assessment of regional function using conventional in-plane tagging. Hypothesis We hypothesize that the use of through-plane tags in the strain-encoding (SENC CMR technique would result in reproducible measurements of the RV regional function due to the high image quality and spatial resolution possible with SENC. Aim To test the intra- and inter-observer variabilities of RV peak systolic strain measurements with SENC CMR for assessment of RV regional function (systolic strain in healthy volunteers. Methods Healthy volunteers (n = 21 were imaged using SENC. A four-chamber view was acquired in a single breath-hold. Circumferential strain was measured during systole at six equidistant points along the RV free wall. Peak contraction is defined as the maximum value of circumferential strain averaged from the six points, and regional function is defined as the strain value at each point at the time of peak contraction. Results Mean values for peak circumferential strain (± standard deviation of the basal, mid, and apical regions of the RV free wall were -20.4 ± 2.9%, -18.8 ± 3.9%, and -16.5 ± 5.7%, Altman plots showed good intra- and inter-observer agreements with mean difference of 0.11% and 0.32% and limits of agreement of -4.038 to 4.174 and -4.903 to 5.836, respectively. Conclusion SENC CMR allows for rapid quantification of RV regional function with low intra- and inter-observer variabilities, which could permit accurate quantification of regional strain in patients with RV dysfunction.

  1. Echocardiographic assessment of right ventricular functions in healthy subjects who migrated from the sea level to a moderate altitude.

    Science.gov (United States)

    Arısoy, Arif; Topçu, Selim; Demirelli, Selami; Altunkaş, Fatih; Karayakalı, Metin; Çelik, Ataç; Tanboğa, İbrahim Halil; Aksakal, Enbiya; Sevimli, Serdar; Gürlertop, Hanefi Yekta

    2015-11-25

    The aim of this study was to evaluate right ventricle (RV) functions using echocardiography in healthy subjects who migrated from the sea level to moderate altitude (1890 m). The prospective observational in this study population consisted of 33 healthy subjects (23 men; mean age 20.4±3.2 years) who migrated from the sea level to a moderate altitude (Erzurum city centre, 1890 m above sea level) for long-term stay. Subjects underwent echocardiographic evaluation within the first 48 h of exposure to the moderate altitude and at the sixth month of arrival. Conventional echocardiographic parameters such as RV sizes and areas, systolic, and diastolic functional indices [fractional area change (FAC), tricuspid flow velocities, myocardial performance index (MPI), and tricuspid annular plane systolic excursion (TAPSE)] were obtained. Systolic (S) and diastolic (E', A') velocities were acquired from the apical fourchamber view using tissue Doppler imaging. Kolmogorov-Smirnov test, student's t-test, Wilcoxon test, and chi-square test were used in this study. There were no significant changes in RV size, FAC, MPI, TAPSE, inferior inspiratory vena cava collapse, tricuspid E velocity, and tricuspid annulus E' velocity. Compared with the baseline, there was a significant increase in mean pulmonary artery pressure (p=0.001); RV end systolic area (p=0.014); right atrial end diastolic area (p=0.021); tricuspid A velocity (p=0.013); tricuspid annulus S and A' velocity (p=0.031 and p=0.006, respectively); and RV free wall S, E', and A' velocity (p=0.007, pa significant decrease in tricuspid E/A ratio (1.61±0.3 vs. 1.45±0.2, p=0.038) and tricuspid annulus E'/A' ratio (1.52±0.5 vs. 1.23±0.4, p=0.002) at the sixth month. Our study revealed that right ventricular diastolic function was altered while the systolic function was preserved in healthy subjects who migrated from the sea level to a moderate altitude.

  2. Noninvasive assessment of changes in myocardial perfusion and ventricular performance following exercise training

    International Nuclear Information System (INIS)

    Tubau, J.; Witztum, K.; Froelicher, V.; Jensen, D.; Atwood, E.; McKirnan, M.D.; Reynolds, J.; Ashburn, W.

    1982-01-01

    Seventeen coronary patients (CAD) underwent 201 Tl treadmill and radionuclide (RNV) ejection fraction supine bicycle testing before and after 5.6 +/- 1.6 (mean +/- SD) months of an exercise program. Thallium data were assessed both using analog images and a computerized circumferential profile technique. Patients exercised on the treadmill to a higher workload after the exercise program, but achieved a similar pressure-rate product. When interpreting the analog thallium images, only 50% agreement was obtained for the assessment of changes in myocardial perfusion (pre/post-training). The computer technique, however, had low inter-intraobserver variability (6%) and better agreement (90.5%). Using the circumferential profile method, five patients improved (a total of 11 regions) and one patient worsened (with two regions). Before the exercise program, the ejection fraction (EF) response to supine bike exercise was normal (an increase greater than 11%) in four, flat in seven, and severely abnormal (a decrease of more than 4%) in six patients. After the exercise program, even though achieving similar or higher pressure-rate products, six patients improved their EF response, nine did not change, and two worsened. Of the five patients who improved their thallium images, one improved his EF response, two remained normal, and two did not change. One patient worsened both his thallium study and the EF response after the exercise program. Changes in thallium exercise images and the EF response to supine exercise occurred in our patients after an exercise program, but were not always concordant. Indeed, of five patients with exercise-induced ischemic ST changes before and after training, the EF response improved in three whereas myocardial perfusion was unchanged. Reasons for this lack of agreement are discussed, and have been considered in the planning of a randomized trial of the effects of an exercise program on myocardial perfusion and function

  3. Tricuspid annular plane systolic excursion in the assessment of right ventricular function in children and adolescents after repair of tetralogy of Fallot.

    Science.gov (United States)

    Mercer-Rosa, Laura; Parnell, Aimee; Forfia, Paul R; Yang, Wei; Goldmuntz, Elizabeth; Kawut, Steven M

    2013-11-01

    Assessing right ventricular (RV) performance is essential for patients with tetralogy of Fallot (TOF). The aim of this study was to investigate the reliability and validity of tricuspid annular plane systolic excursion (TAPSE) against cardiac magnetic resonance imaging measures and cardiopulmonary exercise testing. A retrospective study was performed in 125 outpatients with repaired TOF with available protocol-driven echocardiography, cardiac magnetic resonance imaging, and exercise stress testing obtained as part of a cross-sectional study. TAPSE was measured on the two-dimensional apical four-chamber view on echocardiography by two readers. Multivariate linear regression was used to examine the association between TAPSE and measures of RV function and exercise capacity. The mean age was 12.6 ± 3.3 years, 41 patients (33%) were female, and 104 (83%) were white. TAPSE averaged 1.6 ± 0.37 cm, with an interreader intraclass correlation coefficient of 0.78 (n = 18). TAPSE was significantly associated with cardiac magnetic resonance-based RV stroke volume after adjustment for gender and body surface area (β = 13.8; 95% confidence interval, 2.25-25.30; P = .02). TAPSE was not associated with cardiac magnetic resonance-based RV ejection fraction (P = .77). On exercise testing, TAPSE was not associated with peak oxygen consumption, percentage of predicted oxygen consumption, oxygen pulse, or the ventilatory equivalent for carbon dioxide in patients with maximal exercise stress testing (n = 73 [58%]). TAPSE is reproducibly measured by echocardiography in patients with TOF. It is not associated with RV ejection fraction or exercise performance, and its association with RV stroke volume may be confounded by body size. On the basis of these results, TAPSE is not representative of global RV performance in patients with TOF. Copyright © 2013 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

  4. Assessment of sustained effects of levosimendan and dobutamine on left ventricular systolic functions by using novel tissue Doppler derived indices in patients with advanced heart failure.

    Science.gov (United States)

    Oner, Ender; Erturk, Mehmet; Birant, Ali; Kurtar Mansıroglu, Aslı; Akturk, Ibrahim Faruk; Karakurt, Huseyin; Yalcin, Ahmet Arif; Uzun, Fatih; Somuncu, Mustafa Umut; Yildirim, Aydin

    2015-01-01

    Previous studies comparing levosimendan vs. dobutamine have revealed that levosimendan is better in relieving symptoms. Echocardiographic studies have been done using second measurements immediately following a dobutamine infusion or while it was still being administered. The aim of our study was assessment of sustained effects of 24 h levosimendan and dobutamine infusions on left ventricular systolic functions. A total of 61 patients with acutely decompensated heart failure with New York Heart Association (NYHA) class III or IV symptoms were randomized to receive either levosimendan or dobutamine 2:1 in an open label fashion. Before and 5 days after the initiation of infusions, functional class was assessed, N-terminal prohormone of B-type natriuretic peptide (NT-proBNP) levels and left ventricular ejection fraction (LVEF), mitral inflow peak E and A wave velocity, and E/A ratios were measured; using tissue Doppler imaging, isovolumic myocardial acceleration (IVA), peak myocardial velocity during isovolumic contraction (IVV), peak systolic velocity during ejection period (Sa), early (E') and late (A') diastolic velocities, and E'/A' and E/E' ratios were measured. The NYHA class improved in both groups, but improvements were prominent in the levosimendan group. NT-proBNP levels were significantly reduced in the levosimendan group. Improvements in LVEF and diastolic indices were significant in the levosimendan group. Tissue Doppler-derived systolic indices of IVV and IVA increased significantly in the levosimendan group. Improvements in left ventricular systolic and diastolic functions continue after a levosimendan infusion.

  5. Response of right ventricular size, function, and pressure to supine exercise: a comparison of patients with chronic obstructive lung disease and normal subjects

    Energy Technology Data Exchange (ETDEWEB)

    Slutsky, R; Hooper, W; Ackerman, W; Moser, K

    1982-12-01

    The response of right ventricular ejection fraction (RVEF) and right ventricular end-diastolic volume (RVEDV) to exercise was studied in 11 patients with severe (FEV/sub 25/sub(%)sub(-)/sub 75/sub(%)=0.32+-0.13, mean+-SD) chronic obstructive pulmonary disease (COPD). Using gated radionuclide cardiac blood pool imaging techniques, the response of the patients with COPD was compared with that of 15 control subjects. Arterial blood gases, pulmonary arterial pressures, wedge pressure, and right ventricular pressures also were monitored in patients with COPD. The resting RVEF was lower and the resting RVEDV was higher in patients with COPD than in normals (both, P<0.01). Two of the 11 COPD patients had a RVEF during rest that was below lower limits, while 10 of 11 patients had RV dilation. Right ventricular end-diastolic pressure, measured during rest in patients with COPD, was normal (6.1+-2.1 mm Hg) and cardiac index was within normal limits (3.55+-0.82 l/min/m/sup 2/). With exercise this cardiac index rose to 5.52+-1.7/min/m/sup 2/(P<0.01) due to the increase in heart rate (83+-18 to 125+-25 beats/min; P<0.01) while stroke volume did not significantly change. During exercise, normal subjects showed an increase in RVEF while RVEDV did not change; in patients with COPD, the RVEF fell and the RVEDV increased. In the patients with COPD, mild resting arterial hypoxemia and hypercapnia were both exaggerated during exercise; and mild resting pulmonary arterial hypertension (PAm=24.3+-7.65 mm Hg) also worsened with exercise (PAm=41+-19 mm Hg, P<0.01). Correlation between change in RVEF and PAm was -0.58, and between change in RVEDV and PAm was 0.63. We conclude that patients with severe COPD often have right ventricular dilation at rest and commonly respond to supine exercise with a fall in FV ejection fraction and further dilation of the right ventricle.

  6. The successful implantation of continuous-flow left ventricular assist device as a destination therapy in Korea: echocardiographic assessment.

    Science.gov (United States)

    Lee, Ga Yeon; Park, Sung-Ji; Kim, Sujin; Choi, Namgyung; Jeong, Dong Seop; Jeon, Eun-Seok; Lee, Young Tak

    2014-01-01

    Left ventricular assist device (LVAD) is a good treatment option for the patients ineligible for cardiac transplantation. Several studies have demonstrated that a ventricular assist device improves the quality of life and prognosis of the patients with end-stage heart failure. A 75-yr-old man debilitated with New York Heart Association (NYHA) functional class III-IV due to severe left ventricular systolic dysfunction received LVAD implantation as a destination therapy. The patient was discharged with improved functional status (NYHA functional class II) after appropriate cardiac rehabilitation and education about how to manage the device and potential emergency situations. This is the first case of successful continuous-flow LVAD implantation as a destination therapy in Korea.

  7. Approaches to Assess Competitiveness of Small and Medium Sized Reactors

    International Nuclear Information System (INIS)

    Kuznetsov, V.; Barkatullah, N.

    2011-01-01

    There is continuing interest in Member States concerning the development and application of small and medium sized reactors (SMRs), i.e., reactors with the equivalent electric power of less than 700 MW. Currently, developed SMRs are in most cases intended for markets different than those in which large nuclear power plants operate. Such markets have essentially different investment requirements, siting flexibility, grid connections and infrastructure restrictions. Therefore, economic factors affecting the competitiveness or competition of SMRs in such markets would also be different from those observed in established markets for electricity production. For example, investment capability may be limited, which would favour capacity addition in smaller increments; grids may be small or weak, which would favour capacities exactly matching the demand; infrastructure and human resource may be insufficient, which would favour less complex operation and maintenance requirements; and non-electrical energy products, such as potable water, may be in demand, which would favour reasonably close plant location to the customer. In practice it is futile to compare a single SMR needs to a single larger capacity plant on an economy of scale basis because SMRs are suitable for those locations that might not be appropriate for larger plants. However, a series of SMRs could be considered comparable to fewer larger plants to achieve the same overall power station capacity. In this case, SMRs have a potential to be competitive by employing alternative design strategies, taking advantage of smaller reactor size, offering a less complex design and operation and maintenance, relying on deployment-in-series approaches, taking an advantage of the accelerated learning, multiple unit factors and shorter construction duration. Reflecting on developments in member states, the International Atomic Energy Agency (IAEA) is finalizing the preparation of a report highlighting the economics and

  8. Application of the four formula of software ECToolbox for the assessment of left ventricular ejection fraction in myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Xia Wei; Ni Jing; Zhuang Juhua; Hu Cuihua

    2014-01-01

    Objective: To compare the four formula of software programs ECToolbox for the assessment of left ventricular ejection fraction (LVEF) with equilibrium radionuclide ventriculography. And to calculate the normal cutoff values for the four formula. Methods: A total of 103 patients (59 men, 44 women) were recruited into the study. Thirty-eight patients had known CAD and sixty-five were referred with suspicion of CAD. All the patients underwent equilibrium radionuclide ventriculograph (ERNV) and ECG-gated myocardial perfusion SPECT (GMPS) as the standard protocol. LVEF values were separately calculated with formula R_0, R_1, R_2, R_3 of ECToolbox software, and the results were compared with LVEF values from ERNV. The normal cutoff values for the four formula were calculated by using normal cutoff values greater than or equal to 50% in ERNV as the classifying variable. Results: The mean LVEF on ERNV was 54.6% ± 17.5%. The mean LVEF values for formula R_0, R_1, R_2, R_3 were 64.1% ± 15.7%, 56.3% ± 15.1%, 69.9% ± 17.9%, 56.3% ± 13.6%, respectively. On correlation analysis, a very strong positive correlation was observed between LVEF values derived by ERNV and those derived by the four formula (all of r values were greater than 0.85, P O.05). Normal cutoff values for LVEF on R_0, R_1, R_2, R_3 were 56.5%, 51.5%, 64.5%, 52.5%, respectively, using a 50% or more cutoff value on ERNV. Conclusion: A strong correlation was observed among the four formula of ECToolbox software programs when compared with ERNV. However, there are subtle differences in the objective values of LVEF generated by individual calculation methods, which must be taken into account for clinical studies. (authors)

  9. Two-dimensional color Doppler echocardiography for left ventricular stroke volume assessment: a comparison study with three-dimensional echocardiography.

    Science.gov (United States)

    Silva, Cristina Da; Pedro, Fátima; Deister, Lizandra; Sahlén, Anders; Manouras, Aristomenis; Shahgaldi, Kambiz

    2012-08-01

    Whether measurement of left ventricular outflow tract diameter (LVOTd) using color Doppler (CD) in order to more accurately define LVOTd is more accurate for determination of stroke volume (SV) than gray scale and compare it with direct measurement of LVOT area (a) using three-dimensional echocardiography (3DE) for SV determination. Twenty-one volunteers were examined. LVOTa was calculated by two-dimensional echocardiography (2DE) using the following formula: π× (d/2)(2) , d = LVOT diameter by gray scale and CD, respectively. Planimetry of LVOTa was performed in parasternal long axis using 3DE. Eccentricity Index was calculated using the lateral and anterior-posterior LVOTd. SV was obtained by four different methods: (1) 2D gray scale, (2) 2D color, (3) LVOTa × LVOT velocity time integral, and (4) SV by Simpson's biplane method. Gray scale LVOTd was significantly smaller compared to LVOTd obtained with CD (P vs 3.67 ± 0.70 cm(2) , P vs 3.61 ± 0.89 cm(2) , P = 0.011). Half of the subjects had at least 17% difference between the lateral and anterior-posterior LVOTd. There were significant differences between SV by 2D gray scale and 2D CD (82.8 ± 17.1 mL vs 92.4 ± 16.8 mL, P vs 90.7 ± 19.8 mL, P = 0.025). Our study demonstrates LVOT being frequently elliptical. SV and LVOTa were found to be similar when comparing 2DE CD and 3DE planimetry and showed higher values in comparison to 2DE gray scale, which suggests 2DE CD to be an alternative approach for SV assessment. © 2012, Wiley Periodicals, Inc.

  10. Assessment of left ventricular mechanical dyssynchrony in left bundle branch block canine model: Comparison between cine and tagged MRI.

    Science.gov (United States)

    Saporito, Salvatore; van Assen, Hans C; Houthuizen, Patrick; Aben, Jean-Paul M M; Strik, Marc; van Middendorp, Lars B; Prinzen, Frits W; Mischi, Massimo

    2016-10-01

    To compare cine and tagged magnetic resonance imaging (MRI) for left ventricular dyssynchrony assessment in left bundle branch block (LBBB), using the time-to-peak contraction timing, and a novel approach based on cross-correlation. We evaluated a canine model dataset (n = 10) before (pre-LBBB) and after induction of isolated LBBB (post-LBBB). Multislice short-axis tagged and cine MRI images were acquired using a 1.5 T scanner. We computed contraction time maps by cross-correlation, based on the timing of radial wall motion and of circumferential strain. Finally, we estimated dyssynchrony as the standard deviation of the contraction time over the different regions of the myocardium. Induction of LBBB resulted in a significant increase in dyssynchrony (cine: 13.0 ± 3.9 msec for pre-LBBB, and 26.4 ± 5.0 msec for post-LBBB, P = 0.005; tagged: 17.1 ± 5.0 msec at for pre-LBBB, and 27.9 ± 9.8 msec for post-LBBB, P = 0.007). Dyssynchrony assessed by cine and tagged MRI were in agreement (r = 0.73, P = 0.0003); differences were in the order of time difference between successive frames of 20 msec (bias: -2.9 msec; limit of agreement: 10.1 msec). Contraction time maps were derived; agreement was found in the contraction patterns derived from cine and tagged MRI (mean difference in contraction time per segment: 3.6 ± 13.7 msec). This study shows that the proposed method is able to quantify dyssynchrony after induced LBBB in an animal model. Cine-assessed dyssynchrony agreed with tagged-derived dyssynchrony, in terms of magnitude and spatial direction. J. MAGN. RESON. IMAGING 2016;44:956-963. © 2016 International Society for Magnetic Resonance in Medicine.

  11. Correlation between coronary artery disease severity, left ventricular mass index and carotid intima media thickness, assessed by radio-frequency

    Directory of Open Access Journals (Sweden)

    Ciccone Marco M

    2011-11-01

    Full Text Available Abstract Background Intima-media thickness of the common carotid artery (CCA-IMT is a validated marker of systemic atherosclerosis process. The aim of this study was to evaluate the association between coronary artery disease (CAD, left ventricular hypertrophy (LVH and CCA-IMT, assessed by Radio Frequency-Quality Intima Media Thickness (RFQIMT method, the next generation of IMT real-time measurement, based on the direct analysis of the radiofrequency signal and endowed with high accuracy and reproducibility in early detection of arterial wall thickness. Methods 115 patients (76 men, mean age: 65.1 ± 12 years referred to our department and shown significant (≥ 70% luminal obstruction stenosis at least in one major epicardial coronary artery were studied. Coronary angiograms were divided for severity and extent of the disease: 79 patients (69% had one, 24 patients (21% two, 12 patients (10% three major epicardial coronary arteries with ≥ 70% stenosis. All patients underwent echocardiography and carotid ultrasound examination, assessed by RF. Results Dividing RFQIMT data in tertiles, dyslipidaemia (31 patients with IMT ≥ 1.20 mm vs 16 with IMT = 0.91-1.19 vs 25 with IMT ≤ 0.9, p = 0.004, LVMI (153.5 ± 20.6 g/m2 in IMT ≥ 1.20 mm vs 131.2 ± 8.4 g/m2 in IMT = 0.91-1.19 mm vs 114.3 ± 11.1 g/m2 in IMT ≤ 0.9 mm, P 2 = 0.88, RFQIMT remained significantly associated with the dyslipidemia (regression coefficient ± standard error [SE]: 0.057 ± 0.023; p = 0.017, LVMI (regression coefficient ± SE: 0.01 ± 0.001; P Conclusions RFQIMT is a sophisticated method for carotid ultrasound evaluation. Its evaluation in patients with at least one important major epicardial coronary vessel stenosis would help the accuracy in the general assessment of the number of coronary lesions in these patients.

  12. Left Ventricular Systolic Function Assessed by Global Longitudinal Strain is Impaired in Atrial Fibrillation Compared to Sinus Rhythm

    DEFF Research Database (Denmark)

    Agner, Bue Fridolin Ross; Katz, Michael G; Williams, Zachary R

    2018-01-01

    Background: Atrial fibrillation (AF) is the most common aberrant cardiac arrhythmia. Many AF patients present with symptoms of dyspnea and fatigue, but have normal left ventricular ejection fraction (LVEF). Purpose: To determine the reproducibility of measurements of global longitudinal strain (GLS...

  13. Myocardial Steatosis and Left Ventricular Function in Type 2 Diabetes Mellitus : Assessed with Magnetic Resonance Imaging and Spectroscopy

    NARCIS (Netherlands)

    Meer, Rutger Wouter van der

    2008-01-01

    The aim of the thesis was to provide more insight into the influence of myocardial steatosis on left ventricular function in healthy volunteers and in patients with type 2 diabetes mellitus. Therefore we developed a reproducible proton magnetic resonance (MR) spectroscopic technique with respiratory

  14. High interobserver variability in the assessment of epsilon waves : Implications for diagnosis of arrhythmogenic right ventricular cardiomyopathy/dysplasia

    NARCIS (Netherlands)

    Platonov, Pyotr G; Calkins, Hugh; Hauer, Richard N; Corrado, Domenico; Svendsen, Jesper H; Wichter, Thomas; Biernacka, Elżbieta Katarzyna; Saguner, Ardan M; Te Riele, Anneline S J M; Zareba, Wojciech

    BACKGROUND: Revision of the Task Force diagnostic criteria for arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVC/D) has increased their sensitivity for the diagnosis of early and familial forms of the disease. The epsilon wave is a major diagnostic criterion in the context of ARVC/D,

  15. Epicardial fat thickness correlates with P-wave duration, left atrial size and decreased left ventricular systolic function in morbid obesity.

    Science.gov (United States)

    Fernandes-Cardoso, A; Santos-Furtado, M; Grindler, J; Ferreira, L A; Andrade, J L; Santo, M A

    2017-08-01

    Epicardial fat (EF) is increased in obesity and has important interactions with atrial and ventricular myocardium. Most of the evidence in this scenario can be confused by the presence of comorbidities such as hypertension, diabetes and dyslipidemia, which are very common in this population. The influence of EF on atrial remodeling and cardiac function demands further investigation on morbidly obese without these comorbidities. We prospectively recruited 20 metabolically healthy morbidly obese and 20 normo-weights controls. The maximum P-wave duration (PWD) was analyzed by 12-lead electrocardiogram. Left atrial diameter (LAD), left ventricular ejection fraction (LVEF) and EF thickness (EFT) were evaluated by two-dimensional echocardiography. The mean of maximum PWD and LAD were significantly larger in the obese group as compared to the control group: 109.55 ± 11.52 ms × 89.38 ± 11.19 ms and 36.12 ± 3.46 mm × 31.45 ± 2.64 mm, (p function. Copyright © 2017 The Italian Society of Diabetology, the Italian Society for the Study of Atherosclerosis, the Italian Society of Human Nutrition, and the Department of Clinical Medicine and Surgery, Federico II University. Published by Elsevier B.V. All rights reserved.

  16. Assessment of left ventricular deformation in patients with Ebstein’s anomaly by cardiac magnetic resonance tissue tracking

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xi; Zhang, Qin [Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Yang, Zhi-gang, E-mail: yangzg666@163.com [Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Shi, Ke; Xu, Hua-yan [Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Xie, Lin-jun [Department of Radiology, West China Second University Hospital, Sichuan University, 20# Section 3 South Renmin Road, Chengdu, Sichuan 610041 (China); Jiang, Li; Diao, Kai-yue [Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Guo, Ying-kun [Department of Radiology, West China Second University Hospital, Sichuan University, 20# Section 3 South Renmin Road, Chengdu, Sichuan 610041 (China)

    2017-04-15

    Purpose: The aim of this study was to clarify the feasibility of myocardial strain using cardiovascular magnetic resonance (CMR) for the evaluation of left ventricular (LV) deformation in patients with Ebstein’s anomaly (EA). Materials and methods: We recruited 32 patients with EA and 30 controls for CMR examination and measured LV function, dimension and tissue tracking parameters (the global and regional radial, circumferential and longitudinal peak strain), together with the right ventricle (RV) dimension. LV strain parameters were compared among the controls, patients with preserved LV ejection fraction (LVEF; ≥55%), and patients with reduced LVEF (<55%). Pearson’s correlation was used to evaluate relationships between tissue tracking parameters with the RVEDD/LVEDD index and LVEF. An ROC analysis was also performed to determine whether the cut-off values for PS could be used to differentiate LV dysfunction between patients with EA and controls. The intraclass correlation coefficient (ICC) was used to assess the inter- and intra-observer variability. Results: The global strain parameters all decreased significantly in the EA group compared with the control group (all P < 0.05). Furthermore, the global radial and circumferential peak strain (PS) were obviously even lower in the reduced LVEF group than the strain measured in preserved LVEF groups (28.64% vs. 37.39%, p < 0.05; and −8.20% vs. −17.89%; p < 0.05; respectively). The regional strain abnormalities in EA patients were mainly involved in basal and middle segments. The results also demonstrated a significant correlation between the ratio of the RV end-diastolic dimension to the LV end-diastolic dimension (RVEDD/LVEDD index) with the global circumferential PS (r = 0.508) and the longitudinal PS (r = 0.474), as well as a good correlation between radial PS and LVEF (r = 0.465). The ICCs for intra- and inter-observer variability were 0.797–0.904 and 0.701–0.896. Conclusions: LV strain serves an

  17. Left Ventricular Function Assessed by One-Point Carotid Wave Intensity in Newly Diagnosed Untreated Hypertensive Patients.

    Science.gov (United States)

    Vriz, Olga; Favretto, Serena; Jaroch, Joanna; Wojciech, Rychard; Bossone, Eduardo; Driussi, Caterina; Antonini-Canterin, Francesco; Palatini, Paolo; Loboz-Grudzien, Krystyna

    2017-01-01

    To investigate whether newly diagnosed untreated hypertensive patients show higher left ventricular (LV) contractility, as assessed by traditional echocardiographic indices and carotid wave intensity (WI) parameters, including amplitude of the peak during early (W 1 ) and late systole (W 2 ). A total of 145 untreated hypertensive patients were compared with 145 age- and sex-matched normotensive subjects. They underwent comprehensive echocardiography and WI analysis. WI analysis was performed at the level of the common carotid artery. The diameter changes were the difference between the displacement of the anterior and posterior walls, with the cursors set to track the media-adventitia boundaries 2 cm proximal to the carotid bulb and calibrated by systolic and diastolic BP. Peak acceleration was derived from blood flow velocity measured by Doppler sonography with the range-gate positioned at the center of the vessel diameter. WI was based on the calculation of (dP/dt)×(dU/dt), where dP/dt and dU/dt were the derivatives of BP (P) and velocity (U) with respect to time. One-point pulse wave velocity (PWVβ) and the interval between the R wave on ECG and the first peak of WI (R-W 1 ), using a high definition echo-tracking system implemented in the ultrasound machine (Aloka), were also derived. After adjustment for body weight, heart rate, and physical activity, the two groups had similar general characteristics and diastolic function. However, hypertensives showed significantly higher LV mass, LV ejection fraction (LVEF), circumferential and LV end-systolic stress, and one-point PWV as well as W 1 (13.646 ± 7.368 vs 9.308 ± 4.675 mmHg m/s 3 , P =.001) and W 2 (4.289 ± 2.017 vs 2.995 ± 1.868 mmHg m/s 3 , P =.001). Hypertensives were divided into tertiles according to LVEF: W 1 (11.934 ± 5.836 vs 11.576 ± 5.857 vs 17.227 ± 8.889 mmHg m/s 3 , P function. © 2016 by the American Institute of Ultrasound in Medicine.

  18. Do Effect-Size Measures Measure up?: A Brief Assessment

    Science.gov (United States)

    Onwuegbuzie, Anthony J.; Levin, Joel R.; Leech, Nancy L.

    2003-01-01

    Because of criticisms leveled at statistical hypothesis testing, some researchers have argued that measures of effect size should replace the significance-testing practice. We contend that although effect-size measures have logical appeal, they are also associated with a number of limitations that may result in problematic interpretations of them…

  19. Diagnostic accuracy of cardiovascular magnetic resonance imaging of right ventricular morphology and function in the assessment of suspected pulmonary hypertension results from the ASPIRE registry

    Directory of Open Access Journals (Sweden)

    Swift Andrew J

    2012-06-01

    Full Text Available Abstract Background Cardiovascular Magnetic Resonance (CMR imaging is accurate and reproducible for the assessment of right ventricular (RV morphology and function. However, the diagnostic accuracy of CMR derived RV measurements for the detection of pulmonary hypertension (PH in the assessment of patients with suspected PH in the clinic setting is not well described. Methods We retrospectively studied 233 consecutive treatment naïve patients with suspected PH including 39 patients with no PH who underwent CMR and right heart catheterisation (RHC within 48hours. The diagnostic accuracy of multiple CMR measurements for the detection of mPAP ≥ 25 mmHg was assessed using Fisher’s exact test and receiver operating characteristic (ROC analysis. Results Ventricular mass index (VMI was the CMR measurement with the strongest correlation with mPAP (r = 0.78 and the highest diagnostic accuracy for the detection of PH (area under the ROC curve of 0.91 compared to an ROC of 0.88 for echocardiography calculated mPAP. Late gadolinium enhancement, VMI ≥ 0.4, retrograde flow ≥ 0.3 L/min/m2 and PA relative area change ≤ 15% predicted the presence of PH with a high degree of diagnostic certainty with a positive predictive value of 98%, 97%, 95% and 94% respectively. No single CMR parameter could confidently exclude the presence of PH. Conclusion CMR is a useful alternative to echocardiography in the evaluation of suspected PH. This study supports a role for the routine measurement of ventricular mass index, late gadolinium enhancement and the use of phase contrast imaging in addition to right heart functional indices in patients undergoing diagnostic CMR evaluation for suspected pulmonary hypertension.

  20. Early evaluation of cerebral metabolic rate of glucose (CMRglu) with {sup 18}F-FDG PET/CT and clinical assessment in idiopathic normal pressure hydrocephalus (INPH) patients before and after ventricular shunt placement: preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Calcagni, Maria Lucia; Lavalle, Mariadea; Leccisotti, Lucia; Giordano, Alessandro [Universita Cattolica del Sacro Cuore, Institute of Nuclear Medicine, Rome (Italy); Mangiola, Annunziato; De Bonis, Pasquale; Anile, Carmelo [Universita Cattolica del Sacro Cuore, Institute of Neurosurgery, Rome (Italy); Indovina, Luca [Universita Cattolica del Sacro Cuore, Institute of Physics, Rome (Italy); Marra, Camillo [Universita Cattolica del Sacro Cuore, Institute of Neurology, Rome (Italy); Pelliccioni, Armando [Istituto Nazionale per l' Assicurazione contro gli Infortuni sul Lavoro (INAIL), Rome (Italy)

    2012-02-15

    We evaluated the relationships between the cerebral metabolic rate of glucose (CMRglu) measured by dynamic {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) and the clinical and neuropsychological assessment before and after the surgical procedure in idiopathic normal pressure hydrocephalus (INPH) patients. Eleven selected INPH patients underwent clinical assessment (modified Rankin scale, Krauss scale, Larsson categorization system and Stein-Langfitt scale), cognitive evaluation (Mini-Mental State Examination, MMSE) and dynamic {sup 18}F-FDG PET/CT scan 3 days before and 1 week after ventricular shunt placement. After shunting, the global CMRglu significantly increased (2.95 {+-} 0.44 vs 4.38 {+-} 0.68, p = 10{sup -7}) in all INPH patients with a mean percentage value of 48.7%. After shunting, no significant change was found in the Evans ratio whereas a significant decrease in all clinical scale scores was observed. Only a slight reduction in the MMSE was found. After shunting, a significant correlation between the global CMRglu value and clinical assessment was found (R {sup 2} = 0.75, p = 0.024); indeed all clinical scale scores varied (decreasing) and the CMRglu value also varied (increasing) in all INPH patients. Our preliminary data show that changes in the CMRglu are promptly reversible after surgery and that there is a relationship between the early metabolic changes and clinical symptoms, independently from the simultaneous changes in the ventricular size. The remarkable and prompt improvement in the global CMRglu and in symptoms may also have important implications for the current concept of ''neuronal plasticity'' and for the cells' reactivity in order to recover their metabolic function. (orig.)

  1. Early evaluation of cerebral metabolic rate of glucose (CMRglu) with 18F-FDG PET/CT and clinical assessment in idiopathic normal pressure hydrocephalus (INPH) patients before and after ventricular shunt placement: preliminary experience

    International Nuclear Information System (INIS)

    Calcagni, Maria Lucia; Lavalle, Mariadea; Leccisotti, Lucia; Giordano, Alessandro; Mangiola, Annunziato; De Bonis, Pasquale; Anile, Carmelo; Indovina, Luca; Marra, Camillo; Pelliccioni, Armando

    2012-01-01

    We evaluated the relationships between the cerebral metabolic rate of glucose (CMRglu) measured by dynamic 18 F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) and the clinical and neuropsychological assessment before and after the surgical procedure in idiopathic normal pressure hydrocephalus (INPH) patients. Eleven selected INPH patients underwent clinical assessment (modified Rankin scale, Krauss scale, Larsson categorization system and Stein-Langfitt scale), cognitive evaluation (Mini-Mental State Examination, MMSE) and dynamic 18 F-FDG PET/CT scan 3 days before and 1 week after ventricular shunt placement. After shunting, the global CMRglu significantly increased (2.95 ± 0.44 vs 4.38 ± 0.68, p = 10 -7 ) in all INPH patients with a mean percentage value of 48.7%. After shunting, no significant change was found in the Evans ratio whereas a significant decrease in all clinical scale scores was observed. Only a slight reduction in the MMSE was found. After shunting, a significant correlation between the global CMRglu value and clinical assessment was found (R 2 = 0.75, p = 0.024); indeed all clinical scale scores varied (decreasing) and the CMRglu value also varied (increasing) in all INPH patients. Our preliminary data show that changes in the CMRglu are promptly reversible after surgery and that there is a relationship between the early metabolic changes and clinical symptoms, independently from the simultaneous changes in the ventricular size. The remarkable and prompt improvement in the global CMRglu and in symptoms may also have important implications for the current concept of ''neuronal plasticity'' and for the cells' reactivity in order to recover their metabolic function. (orig.)

  2. Clinical values of left ventricular mechanical dyssynchrony assessment by gated myocardial perfusion SPECT in patients with acute myocardial infarction and multivessel disease

    International Nuclear Information System (INIS)

    Cho, Sang-Geon; Park, Ki Seong; Kim, Jahae; Kim, Jong Sang; Song, Ho-Chun; Jabin, Zeenat; Kang, Sae-Ryung; Kwon, Seong Young; Jeong, Geum-Cheol; Song, Minchul; Min, Jung-Joon; Bom, Hee-Seung; Cho, Jae Yeong; Kim, Hyun Kuk

    2017-01-01

    The aim of this study was to evaluate the prognostic value of additional evaluation of left ventricular mechanical dyssynchrony (LVMD) by gated myocardial perfusion single-photon emission computed tomography (GMPS) in patients with acute myocardial infarction (MI) and multivessel disease. One hundred and nine acute MI patients with >50 % stenosis in at least one non-culprit artery who underwent GMPS within 2 weeks were enrolled. All patients underwent successful revascularization of the culprit arteries. Those with previous MI, atrial fibrillation, or frequent ventricular premature complexes, cardiac devices, significant patient motion, or procedure-related events were excluded. Phase standard deviation (PSD) and phase histogram bandwidth (PBW) were measured for assessment of LVMD. Patients were followed up for a median of 26 months after index MI, for composite major adverse cardiac events (MACE), which consisted with all-cause death, unplanned hospitalization due to heart failure and severe ventricular arrhythmias (sustained ventricular tachycardia or ventricular fibrillation). Independent predictors of MACE were evaluated. MACE occurred in 22 patients (20 %). Stress PSD (53.3 ± 17.3 vs. 35.3 ± 18.9 ; p <0.001), stress PBW (147.6 ± 54.6 vs. 96.8 ± 59.2 ; p = 0.001) and resting PBW (126.8 ± 37.5 vs. 96.6 ± 48.9 ; p = 0.001) were significantly higher in patients with MACE compared to those without. Multivariate analysis revealed that stress PSD ≥45.5 and stress PBW ≥126.0 were predictive of MACE, as well as suboptimal non-culprit artery revascularization (SNR) and renin-angiotensin system (RAS) blockade medication. Higher stress PSD and stress PBW were associated with poorer prognosis both in patients with and without SNR, and those with RAS blockade medication, but not in those without RAS blockade medication. LVMD measured by GMPS showed added prognostic value in acute MI with multivessel disease. GMPS could serve as a comprehensive evaluation imaging

  3. Clinical values of left ventricular mechanical dyssynchrony assessment by gated myocardial perfusion SPECT in patients with acute myocardial infarction and multivessel disease

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Sang-Geon; Park, Ki Seong; Kim, Jahae; Kim, Jong Sang; Song, Ho-Chun [Chonnam National University Hospital, Department of Nuclear Medicine, Gwang-ju (Korea, Republic of); Jabin, Zeenat; Kang, Sae-Ryung; Kwon, Seong Young; Jeong, Geum-Cheol; Song, Minchul; Min, Jung-Joon; Bom, Hee-Seung [Chonnam National University Hwasun Hospital, Department of Nuclear Medicine, Hwasun-gun, Jeonnam (Korea, Republic of); Cho, Jae Yeong; Kim, Hyun Kuk [Chonnam National University Hospital, Department of Cardiology, Gwang-ju (Korea, Republic of)

    2017-02-15

    The aim of this study was to evaluate the prognostic value of additional evaluation of left ventricular mechanical dyssynchrony (LVMD) by gated myocardial perfusion single-photon emission computed tomography (GMPS) in patients with acute myocardial infarction (MI) and multivessel disease. One hundred and nine acute MI patients with >50 % stenosis in at least one non-culprit artery who underwent GMPS within 2 weeks were enrolled. All patients underwent successful revascularization of the culprit arteries. Those with previous MI, atrial fibrillation, or frequent ventricular premature complexes, cardiac devices, significant patient motion, or procedure-related events were excluded. Phase standard deviation (PSD) and phase histogram bandwidth (PBW) were measured for assessment of LVMD. Patients were followed up for a median of 26 months after index MI, for composite major adverse cardiac events (MACE), which consisted with all-cause death, unplanned hospitalization due to heart failure and severe ventricular arrhythmias (sustained ventricular tachycardia or ventricular fibrillation). Independent predictors of MACE were evaluated. MACE occurred in 22 patients (20 %). Stress PSD (53.3 ± 17.3 vs. 35.3 ± 18.9 ; p <0.001), stress PBW (147.6 ± 54.6 vs. 96.8 ± 59.2 ; p = 0.001) and resting PBW (126.8 ± 37.5 vs. 96.6 ± 48.9 ; p = 0.001) were significantly higher in patients with MACE compared to those without. Multivariate analysis revealed that stress PSD ≥45.5 and stress PBW ≥126.0 were predictive of MACE, as well as suboptimal non-culprit artery revascularization (SNR) and renin-angiotensin system (RAS) blockade medication. Higher stress PSD and stress PBW were associated with poorer prognosis both in patients with and without SNR, and those with RAS blockade medication, but not in those without RAS blockade medication. LVMD measured by GMPS showed added prognostic value in acute MI with multivessel disease. GMPS could serve as a comprehensive evaluation imaging

  4. Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure

    International Nuclear Information System (INIS)

    Maier, Joscha; Sawall, Stefan; Kachelrieß, Marc

    2014-01-01

    Purpose: Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levels from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Methods: Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Results: Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the

  5. Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure.

    Science.gov (United States)

    Maier, Joscha; Sawall, Stefan; Kachelrieß, Marc

    2014-05-01

    Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levels from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the HDTV algorithm shows the

  6. Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure

    Energy Technology Data Exchange (ETDEWEB)

    Maier, Joscha, E-mail: joscha.maier@dkfz.de [Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Sawall, Stefan; Kachelrieß, Marc [Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany and Institute of Medical Physics, University of Erlangen–Nürnberg, 91052 Erlangen (Germany)

    2014-05-15

    Purpose: Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levels from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Methods: Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Results: Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the

  7. Equilibrium radionuclide assessment of left ventricular ejection and filling. Comparison of list mode-and multigated frame-mode measurements

    Energy Technology Data Exchange (ETDEWEB)

    Sugrue, D.D.; McKenna, W.J.; Dickie, S.; Oakley, C.M.; Myers, M.J.; Lavender, J.P. (Royal Postgraduate Medical School, London (UK))

    1983-10-01

    The relationship as studied between radionuclide indices of left ventricular systolic and diastolic function acquired in conventional multigated frame-mode compared to list-mode in patients with sinus rhythm. The study showed that frame-mode and list-mode measurements of ejection and filling indices are not significantly different in these patients but that backward reformatting of data acquired in list-mode is necessary to measure the atrial contribution to LV stroke counts. It was concluded that valid measurements of left ventricular systolic ejection and diastolic filling can be made in patients in sinus rhythm using frame-mode acquisition with the exception of measurements of the contribution from atrial systole to stroke volume.

  8. Phase analysis of regional and global ventricular contraction patterns in Wolff-Parkinson-White syndrome. Assessment by radionuclide ventriculography

    Energy Technology Data Exchange (ETDEWEB)

    Konishi, Tokuji; Koyama, Takao; Ichikawa, Takehiko and others

    1989-04-01

    Multigated blood pool scintigraphy was performed in 20 normal subjects and 39 patients with various intraventricular conduction abnormalities, including 25 patients with Wolff-Parkinson-White (WPW) syndrome. Cardiac imaging was performed in the modified left anterior oblique, right anterior oblique, and left lateral projections. In WPW syndrome, early contraction sites which were not seen in normal subjects were detected at the ventricular base in phase images. These anomalous early contraction sites disappeared after successful suppression of conduction through an accessory pathway by intravenous procainamide. These sites are believed to correspond to the location of the bundle of Kent and were consistent with the electrocardiographic findings. Phase mapping is a suitable noninvasive method to locate the position of the bundle of Kent and evaluate the ventricular contraction pattern in WPW syndrome and other intraventricular conduction abnormalities. (author).

  9. Cine MR imaging assessment of regional left ventricular systolic wall thickening in patients with remote myocardial infarction

    International Nuclear Information System (INIS)

    Pfugfelder, P.; White, R.D.; Sechtem, U.; Gould, R.G.; Higgins, C.B.

    1986-01-01

    Cine MR imaging, a new rapid imaging technique, was used to acquire transverse images of the heart at a rate of 16-30 frames per cardiac cycle. Left ventricular wall thickness was measured at end diastole and end systole in six regions in the midventricular section of 13 healthy subjects and seven patients with previously documented myocardial infarction. Mean percent systolic wall thickening (%SWT) was 51% +- 26% in healthy subjects. In patients, %SWT was -8% +- 22% in the infarct zone and 42% +- 22% in the normal myocardium. In addition to the qualitative information derived from the cinematic display, determination of regional %SWT by cine-MR imaging may be useful for quantifying regional left ventricular dysfunction

  10. Assessment of injection bolus in first-pass radionuclide angiography. Evaluation of injection site and needle size

    International Nuclear Information System (INIS)

    Tonami, Syuichi; Inagaki, Syoichi; Yasui, Masakazu; Sugishita, Kouki; Yoshita, Hisashi; Nakamura, Mamoru; Kuranishi, Makoto

    1996-01-01

    First-pass radionuclide angiography (FPRNA) using a multi-crystal gamma camera can correctly provide many quantitative and qualitative indices of left ventricular function as well as anatomic information. A compact injection bolus of radiotracer is, however, essential to the first-pass study since the temporal separation of cardiac chambers is required for the first-pass acquisition. To examine which factors affect the quality of an injection bolus, 327 patients who had FPRNA in the anterior projection were randomized for injection site of radiotracer (right or left external jugular veins, and right antecubital vein) and needle size (19- or 21-gauge). The injected bolus was assessed from the full width at half maximum (FWHM) of the bolus time-activity curve in the superior vena cava. As to injection site using a 19-gauge needle, an attemption through right external jugular vein (EJV) revealed the shortest FWHM of an injection bolus, followed by left EJV and right antecubital vein (AV). In right EJV 91% of injected bolus FWHM was less than 1.5 sec, which was significantly higher (p<0.001) than those of the other sites (left EJV: 70%. right AV: 65%). Approximately 7% of injection from left EJV and right AV, showed a split bolus of radiotracer. However, no split bolus was observed from right EJV. There was no significant difference in FWHM of an injection bolus between 19- and 21-gauge needle from EJV. Our present study demonstrated that the quality of an injection bolus from left EJV and AV was affected by RVEF in a case of low right ventricular function. In conclusion, right EJV is the first choice of injection site to obtain a compact bolus of radiotracer for the first-pass cardiac study. A 21-gauge needle can also be inserted from the external jugular vein to perform a good bolus injection. (author)

  11. Assessment of injection bolus in first-pass radionuclide angiography. Evaluation of injection site and needle size

    Energy Technology Data Exchange (ETDEWEB)

    Tonami, Syuichi; Inagaki, Syoichi; Yasui, Masakazu; Sugishita, Kouki; Yoshita, Hisashi; Nakamura, Mamoru; Kuranishi, Makoto [Toyama Medical and Pharmaceutical Univ. (Japan). Hospital

    1996-09-01

    First-pass radionuclide angiography (FPRNA) using a multi-crystal gamma camera can correctly provide many quantitative and qualitative indices of left ventricular function as well as anatomic information. A compact injection bolus of radiotracer is, however, essential to the first-pass study since the temporal separation of cardiac chambers is required for the first-pass acquisition. To examine which factors affect the quality of an injection bolus, 327 patients who had FPRNA in the anterior projection were randomized for injection site of radiotracer (right or left external jugular veins, and right antecubital vein) and needle size (19- or 21-gauge). The injected bolus was assessed from the full width at half maximum (FWHM) of the bolus time-activity curve in the superior vena cava. As to injection site using a 19-gauge needle, an attemption through right external jugular vein (EJV) revealed the shortest FWHM of an injection bolus, followed by left EJV and right antecubital vein (AV). In right EJV 91% of injected bolus FWHM was less than 1.5 sec, which was significantly higher (p<0.001) than those of the other sites (left EJV: 70%. right AV: 65%). Approximately 7% of injection from left EJV and right AV, showed a split bolus of radiotracer. However, no split bolus was observed from right EJV. There was no significant difference in FWHM of an injection bolus between 19- and 21-gauge needle from EJV. Our present study demonstrated that the quality of an injection bolus from left EJV and AV was affected by RVEF in a case of low right ventricular function. In conclusion, right EJV is the first choice of injection site to obtain a compact bolus of radiotracer for the first-pass cardiac study. A 21-gauge needle can also be inserted from the external jugular vein to perform a good bolus injection. (author)

  12. Assessment of global left ventricular function with dual-source computed tomography in patients with valvular heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Bak, So Hyeon; Jeon, Hae Jeong (Dept. of Radiology, Konkuk Univ. Hospital, Konkuk Univ. School of Medicine, Seoul (Korea, Republic of)); Ko, Sung Min (Dept. of Radiology, Konkuk Univ. Hospital, Konkuk Univ. School of Medicine, Seoul (Korea, Republic of); Research Inst. of Medical Science, Konkuk Univ. Hospital, Konkuk Univ. School of Medicine, Seoul (Korea, Republic of)), Email: 20070437@kuh.ac.kr; Yang, Hyun Suk; Hwang, Hweung Kon (Dept. of Cardiology, Konkuk Univ. Hospital, Konkuk Univ. School of Medicine, Seoul (Korea, Republic of)); Song, Meong Gun (Dept. of Thoracic Surgery, Konkuk Univ. Hospital, Konkuk Univ. School of Medicine, Seoul (Korea, Republic of))

    2012-04-15

    Background: Left ventricular (LV) function is a vital parameter for prognosis, therapy guidance, and follow-up of cardiovascular disease. Dual-source computed tomography (DSCT) provides an accurate analysis of global LV function. Purpose: To assess the performance of DSCT in the determination of global LV functional parameters in comparison with cardiovascular magnetic resonance (CMR) and two-dimensional transthoracic echocardiography (2D-TTE) in patients with valvular heart disease (VHD). Material and Methods: A total of 111 patients (58 men, mean age 49.9 years) with known VHD and who underwent DSCT, 2D-TTE, and CMR a period of 2 weeks before undergoing valve surgery were included in this study. LV end-systolic volume (ESV), end-diastolic volume (EDV), stroke volume (SV), and ejection fraction (EF) were calculated by DSCT using the threshold-based technique, by 2D-TTE using a modified Simpson's method, and by CMR using Simpson's method. Agreement for parameters of LV global function was determined with the Pearson's correlation coefficient (r) and Bland-Altman analysis. All the DSCT and CMR data-sets were assessed independently by two readers. Results: Fifty of the total 111 patients had aortic VHD, 29 patients had mitral VHD, and 32 patients had mixed aortic and mitral VHD. An excellent inter-observer agreement was seen for the assessment of global LV function using DSCT (r 0.910-0.983) and CMR (r = 0.854-0.965). An excellent or good correlation (r 0.93, 0.95, 0.87, and 0.71, respectively, P < 0.001) was noted between the DSCT and 2D-TTE values for EDV, ESV, SV, and EF. EDV (33.7 mL, P < 0.001), ESV (12.1 mL, P < 0.001), SV (21.2 mL, P < 0.001), and EF (1.6%, P = 0.019) were significantly overestimated by DSCT when compared with 2D-TTE. An excellent correlation (r = 0.96, 0.97, 0.91, and 0.94, respectively, P < 0.001) between DSCT and CMR was seen in the evaluation of EDV, ESV, SV, and EF. EDV (15.9 mL, P < 0.001), ESV (7.3 mL, P < 0.001), and SV

  13. Assessment of global left ventricular function with dual-source computed tomography in patients with valvular heart disease

    International Nuclear Information System (INIS)

    Bak, So Hyeon; Jeon, Hae Jeong; Ko, Sung Min; Yang, Hyun Suk; Hwang, Hweung Kon; Song, Meong Gun

    2012-01-01

    Background: Left ventricular (LV) function is a vital parameter for prognosis, therapy guidance, and follow-up of cardiovascular disease. Dual-source computed tomography (DSCT) provides an accurate analysis of global LV function. Purpose: To assess the performance of DSCT in the determination of global LV functional parameters in comparison with cardiovascular magnetic resonance (CMR) and two-dimensional transthoracic echocardiography (2D-TTE) in patients with valvular heart disease (VHD). Material and Methods: A total of 111 patients (58 men, mean age 49.9 years) with known VHD and who underwent DSCT, 2D-TTE, and CMR a period of 2 weeks before undergoing valve surgery were included in this study. LV end-systolic volume (ESV), end-diastolic volume (EDV), stroke volume (SV), and ejection fraction (EF) were calculated by DSCT using the threshold-based technique, by 2D-TTE using a modified Simpson's method, and by CMR using Simpson's method. Agreement for parameters of LV global function was determined with the Pearson's correlation coefficient (r) and Bland-Altman analysis. All the DSCT and CMR data-sets were assessed independently by two readers. Results: Fifty of the total 111 patients had aortic VHD, 29 patients had mitral VHD, and 32 patients had mixed aortic and mitral VHD. An excellent inter-observer agreement was seen for the assessment of global LV function using DSCT (r 0.910-0.983) and CMR (r = 0.854-0.965). An excellent or good correlation (r 0.93, 0.95, 0.87, and 0.71, respectively, P < 0.001) was noted between the DSCT and 2D-TTE values for EDV, ESV, SV, and EF. EDV (33.7 mL, P < 0.001), ESV (12.1 mL, P < 0.001), SV (21.2 mL, P < 0.001), and EF (1.6%, P = 0.019) were significantly overestimated by DSCT when compared with 2D-TTE. An excellent correlation (r = 0.96, 0.97, 0.91, and 0.94, respectively, P < 0.001) between DSCT and CMR was seen in the evaluation of EDV, ESV, SV, and EF. EDV (15.9 mL, P < 0.001), ESV (7.3 mL, P < 0.001), and SV (8.5 mL, P < 0

  14. Left Ventricular Assist Devices

    Directory of Open Access Journals (Sweden)

    Khuansiri Narajeenron

    2017-04-01

    Full Text Available Audience: The audience for this classic team-based learning (cTBL session is emergency medicine residents, faculty, and students; although this topic is applicable to internal medicine and family medicine residents. Introduction: A left ventricular assist device (LVAD is a mechanical circulatory support device that can be placed in critically-ill patients who have poor left ventricular function. After LVAD implantation, patients have improved quality of life.1 The number of LVAD patients worldwide continues to rise. Left-ventricular assist device patients may present to the emergency department (ED with severe, life-threatening conditions. It is essential that emergency physicians have a good understanding of LVADs and their complications. Objectives: Upon completion of this cTBL module, the learner will be able to: 1 Properly assess LVAD patients’ circulatory status; 2 appropriately resuscitate LVAD patients; 3 identify common LVAD complications; 4 evaluate and appropriately manage patients with LVAD malfunctions. Method: The method for this didactic session is cTBL.

  15. Qualitative and quantitative assessment of step size adaptation rules

    DEFF Research Database (Denmark)

    Krause, Oswin; Glasmachers, Tobias; Igel, Christian

    2017-01-01

    We present a comparison of step size adaptation methods for evolution strategies, covering recent developments in the field. Following recent work by Hansen et al. we formulate a concise list of performance criteria: a) fast convergence of the mean, b) near-optimal fixed point of the normalized s...... that cumulative step size adaptation (CSA) and twopoint adaptation (TPA) provide reliable estimates of the optimal step size. We further find that removing the evolution path of CSA still leads to a reliable algorithm without the computational requirements of CSA.......We present a comparison of step size adaptation methods for evolution strategies, covering recent developments in the field. Following recent work by Hansen et al. we formulate a concise list of performance criteria: a) fast convergence of the mean, b) near-optimal fixed point of the normalized...

  16. Children's estimates of food portion size: the development and evaluation of three portion size assessment tools for use with children.

    Science.gov (United States)

    Foster, E; Matthews, J N S; Lloyd, J; Marshall, L; Mathers, J C; Nelson, M; Barton, K L; Wrieden, W L; Cornelissen, P; Harris, J; Adamson, A J

    2008-01-01

    A number of methods have been developed to assist subjects in providing an estimate of portion size but their application in improving portion size estimation by children has not been investigated systematically. The aim was to develop portion size assessment tools for use with children and to assess the accuracy of children's estimates of portion size using the tools. The tools were food photographs, food models and an interactive portion size assessment system (IPSAS). Children (n 201), aged 4-16 years, were supplied with known quantities of food to eat, in school. Food leftovers were weighed. Children estimated the amount of each food using each tool, 24 h after consuming the food. The age-specific portion sizes represented were based on portion sizes consumed by children in a national survey. Significant differences were found between the accuracy of estimates using the three tools. Children of all ages performed well using the IPSAS and food photographs. The accuracy and precision of estimates made using the food models were poor. For all tools, estimates of the amount of food served were more accurate than estimates of the amount consumed. Issues relating to reporting of foods left over which impact on estimates of the amounts of foods actually consumed require further study. The IPSAS has shown potential for assessment of dietary intake with children. Before practical application in assessment of dietary intake of children the tool would need to be expanded to cover a wider range of foods and to be validated in a 'real-life' situation.

  17. Cardiac structure and function, and ventricular-arterial interaction 11 years following a pregnancy with preeclampsia.

    Science.gov (United States)

    Al-Nashi, Maha; Eriksson, Maria J; Östlund, Eva; Bremme, Katarina; Kahan, Thomas

    2016-04-01

    Preeclampsia (PE) is associated with acute left ventricular dysfunction. Whether these changes eventually resolve remains unclear. This study assessed left and right ventricular structure and function, and ventricular-arterial interaction in 15 women 11 years after a pregnancy with PE and 16 matched control subjects with a normal pregnancy. We found normal left and right ventricular dimensions, systolic function, and global left ventricular strain, with no differences between the groups. In addition, indices of diastolic function, left and right atrial size, and amino-terminal pro-brain natriuretic peptide were normal and did not differ between the groups. Women with a previous PE had impaired night/day ratios for systolic and diastolic ambulatory blood pressure. However, indices of aortic stiffness or ventricular-arterial coupling did not differ between the groups. In conclusion, we could not demonstrate remaining alterations in systolic or diastolic left or right ventricular function, or in ventricular-arterial interaction in women 11 years after PE. Copyright © 2016 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.

  18. Myocardial viability assessed with fluorodeoxyglucose and PET in patients with Q wave myocardial infarction receiving thrombolysis: relationship to coronary anatomy and ventricular function.

    Science.gov (United States)

    Fragasso, G; Chierchia, S L; Rossetti, E; Sciammarella, M G; Conversano, A; Lucignani, G; Landoni, C; Calori, G; Margonato, A; Fazio, F

    1997-03-01

    In previously thrombolysed patients, we analysed residual myocardial viability using the PET-FDG technique and correlated its presence and extent to the angiographic appearance of the infarct-related vessel and left ventricular function. Thirty-six patients who had undergone intravenous thromboloysis for acute myocardial infarction 4.8 +/- 7.2 months previously were studied. Coronary angiography, left ventriculography, and assessment of myocardial perfusion and metabolism were all performed within 1 week. All patients exhibited perfusion defects consistent with the clinically identified myocardial infarction site. Residual viability, as assessed by the PET-FDG technique, was present in 53% of cases. The infarct-related coronary artery was patent in 19 (53%) patients (TIMI grade 3, 79%); of the remaining 17 with occluded infarct-related arteries, 11 had collaterals to the infarct area. Significant FDG uptake was observed in 63% of patients with a patent infarct-related artery and in 41% of those with an occluded infarct-related artery. The same study protocol was adopted in a control group of 30 patients with myocardial infarction who did not receive thrombolysis. The number of infarct-related patent vessels was significantly lower in these patients (30 vs 53%) (TIMI grade 3, 56%), but the overall percentage of PET viability was again 53%. Qualitative analysis of the regional perfusion pattern showed that the magnitude and severity of the perfusion defect was similar in the two groups, regardless of the presence or absence of FDG uptake. Global left ventricular function was also similar in the two groups. However, regional wall motion was significantly better in the thrombolysed patients with a patent infarct-related artery than in those who had not received thrombolysis and whose culprit vessel was also patent. In conclusion, the results of our study support the notion that early recanalization of the infarct-related artery is critical for preserving left

  19. Ventricular enlargement in multiple sclerosis: a comparison of three-dimensional and linear MRI estimates

    International Nuclear Information System (INIS)

    Turner, B.; Blumhardt, L.D.; Ramli, N.; Jaspan, T.

    2001-01-01

    Atrophy of central white matter is related to irreversible clinical disability in multiple sclerosis (MS) and ventricular enlargement may be a sensitive marker of this tissue loss. Therapeutic trials in MS have provided MRI data for investigation of cerebral atrophy in MS. These studies use almost exclusively two-dimensional (2-D) images, which may be limited in the assessment of three-dimensional (3-D) structures. We used 3-D MRI data to estimate ventricular volumes in 40 patients with MS and 10 healthy controls, to look at associations with clinical disability and the stage of the disease. We then compared simple linear measures of ventricular size from conventional 2-D images, with 3-D volume estimates to establish the best available linear indices of ventricular volume. Mean ventricular volumes were increased in the patients and significantly larger in the more disabled patients. The estimated volume of the third ventricle obtained from 3-D MRI showed the strongest association with the clinical stage of the disease, duration of symptoms and levels of disability. Finally, we confirmed that in patients with MS accurate data on ventricular size can be obtained from 2-D images by two simple and convenient linear measures, the width of the third ventricle and of the anterior horn of the lateral ventricle. (orig.)

  20. Methods of assessing grain-size distribution during grain growth

    DEFF Research Database (Denmark)

    Tweed, Cherry J.; Hansen, Niels; Ralph, Brian

    1985-01-01

    This paper considers methods of obtaining grain-size distributions and ways of describing them. In order to collect statistically useful amounts of data, an automatic image analyzer is used, and the resulting data are subjected to a series of tests that evaluate the differences between two related...... distributions (before and after grain growth). The distributions are measured from two-dimensional sections, and both the data and the corresponding true three-dimensional grain-size distributions (obtained by stereological analysis) are collected. The techniques described here are illustrated by reference...

  1. Quantitative assessment of right ventricular function and pulmonary regurgitation in surgically repaired tetralogy of Fallot using 256-slice CT: comparison with 3-Tesla MRI

    Energy Technology Data Exchange (ETDEWEB)

    Yamasaki, Yuzo; Yonezawa, Masato; Matsuo, Yoshio; Kamitani, Takeshi; Higuchi, Ko; Honda, Hiroshi [Graduate School of Medical Sciences, Kyushu University, Department of Clinical Radiology, Higashi-ku, Fukuoka (Japan); Nagao, Michinobu; Kawanami, Satoshi [Graduate School of Medical Sciences, Kyushu University, Department of Molecular Imaging and Diagnosis, Higashi-ku, Fukuoka (Japan); Yamamura, Kenichiro [Graduate School of Medical Sciences, Kyushu University, Department of Pediatrics, Higashi-ku, Fukuoka (Japan); Sakamoto, Ichiro [Graduate School of Medical Sciences, Kyushu University, Department of Cardiovascular Medicine, Higashi-ku, Fukuoka (Japan); Shiokawa, Yuichi [Graduate School of Medical Sciences, Kyushu University, Department of Cardiovascular Surgery, Higashi-ku, Fukuoka (Japan); Yabuuchi, Hidetake [Graduate School of Medical Sciences, Kyushu University, Department of Health Sciences, Higashi-ku, Fukuoka (Japan)

    2014-12-15

    To compare 256-slice cardiac computed tomography (CCT) with cardiac magnetic resonance (CMR) imaging to assess right ventricular (RV) function and pulmonary regurgitant fraction (PRF) in patients with repaired tetralogy of Fallot (TOF). Thirty-three consecutive patients with repaired TOF underwent retrospective ECG-gated CCT and 3-Tesla CMR. RV and left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and ejection fraction (EF) were measured using CCT and CMR. PRF-CCT (%) was defined as (RVSV - LVSV)/RVSV. PRF-CMR (%) was measured by the phase-contrast method. Repeated measurements were performed to determine intra- and interobserver variability. CCT measurements, including PRF, correlated highly with the CMR reference (r = 0.71-0.96). CCT overestimated RVEDV (mean difference, 17.1 ± 2.9 ml), RVESV (12.9 ± 2.1 ml) and RVSV (4.2 ± 2.0 ml), and underestimated RVEF (-2.6 ± 1.0 %) and PRF (-9.1 ± 2.0 %) compared with CMR. The limits of agreement between CCT and CMR were in a good range for all measurements. The variability in CCT measurements was lower than those in CMR. The estimated effective radiation dose was 7.6 ± 2.6 mSv. 256-slice CCT can assess RV function and PRF with relatively low dose radiation exposure in patients with repaired TOF, but overestimates RV volume and underestimates PRF. (orig.)

  2. Quantitative assessment of right ventricular function and pulmonary regurgitation in surgically repaired tetralogy of Fallot using 256-slice CT: comparison with 3-Tesla MRI

    International Nuclear Information System (INIS)

    Yamasaki, Yuzo; Yonezawa, Masato; Matsuo, Yoshio; Kamitani, Takeshi; Higuchi, Ko; Honda, Hiroshi; Nagao, Michinobu; Kawanami, Satoshi; Yamamura, Kenichiro; Sakamoto, Ichiro; Shiokawa, Yuichi; Yabuuchi, Hidetake

    2014-01-01

    To compare 256-slice cardiac computed tomography (CCT) with cardiac magnetic resonance (CMR) imaging to assess right ventricular (RV) function and pulmonary regurgitant fraction (PRF) in patients with repaired tetralogy of Fallot (TOF). Thirty-three consecutive patients with repaired TOF underwent retrospective ECG-gated CCT and 3-Tesla CMR. RV and left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and ejection fraction (EF) were measured using CCT and CMR. PRF-CCT (%) was defined as (RVSV - LVSV)/RVSV. PRF-CMR (%) was measured by the phase-contrast method. Repeated measurements were performed to determine intra- and interobserver variability. CCT measurements, including PRF, correlated highly with the CMR reference (r = 0.71-0.96). CCT overestimated RVEDV (mean difference, 17.1 ± 2.9 ml), RVESV (12.9 ± 2.1 ml) and RVSV (4.2 ± 2.0 ml), and underestimated RVEF (-2.6 ± 1.0 %) and PRF (-9.1 ± 2.0 %) compared with CMR. The limits of agreement between CCT and CMR were in a good range for all measurements. The variability in CCT measurements was lower than those in CMR. The estimated effective radiation dose was 7.6 ± 2.6 mSv. 256-slice CCT can assess RV function and PRF with relatively low dose radiation exposure in patients with repaired TOF, but overestimates RV volume and underestimates PRF. (orig.)

  3. Determining sample size for assessing species composition in ...

    African Journals Online (AJOL)

    Species composition is measured in grasslands for a variety of reasons. Commonly, observations are made using the wheel-point apparatus, but the problem of determining optimum sample size has not yet been satisfactorily resolved. In this study the wheel-point apparatus was used to record 2 000 observations in each of ...

  4. Assessment of particle size distribution in CO 2 accidental releases

    NARCIS (Netherlands)

    Hulsbosch-Dam, C.E.C.; Spruijt, M.P.N.; Necci, A.; Cozzani, V.

    2012-01-01

    A model was developed to calculate the particle size distribution following the release of pressurised supercritical CO 2. The model combines several sub-models for the different stages of jet break-up and specifically addresses the possible formation of solid particles, which is important for CO 2

  5. Assessment of left ventricular function at different levels of exercise using gold-195m in asymptomatic diabetics

    International Nuclear Information System (INIS)

    Fazio, F.; Margonato, A.; Gerundini, P.; Vicedomini, G.; Gilardi, M.C.; Fregoso, A.; Bencivelli, W.; Milanesi, L.; Pozza, G.

    1985-01-01

    Left ventricular ejection fraction (LVEF) was evaluated by gold-195m first pass ventriculography in 10 diabetic patients with microangiopathy, in 10 diabetics without any complications, and in 10 healthy controls during maximum exercise. No differences among groups were present at rest, but at maximal exercise LVEF was significantly lower in microangiopathic patients than in the other two groups. Also muscle blood flow measured by xenon-133 washout was significantly lower during exercise in microangiopathic subjects. Small-vessel involvement of myocardium and muscle could play a role in the development of cardiovascular abnormalities during exercise in diabetics

  6. Quantitative Assessment of Left Ventricular Function and Myocardial Mass: A Comparison of Coronary CT Angiography with Cardiac MRI and Echocardiography

    International Nuclear Information System (INIS)

    Kara, Bedia; Nayman, Alaaddin; Guler, Ibrahim; Gul, Enes Elvin; Koplay, Mustafa; Paksoy, Yahya

    2016-01-01

    The purpose of this study was to compare the left ventricular parameters obtained from multi-detector row computed tomography (MDCT) studies with two-dimensional echocardiography (2DE), and magnetic resonance imaging (MRI), which is accepted as the gold standard in the evaluation of left ventricular functions. The study also aimed to evaluate whether or not there is a relationship between the MR-Argus and CMR tools software programs which are used in post-process calculations of data obtained by MRI. Forty patients with an average age of 51.4±14.9 years who had been scanned with cardiac MDCT were evaluated with cardiac MRI and 2DE. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), cardiac output (CO), and myocardial mass values calculated by MDCT, MRI, and 2DE were compared with each other. Two different MR software programs were used to compare left ventricular functions. The CMR tools LV tutorials method is accepted as the gold standard because it can be used in three-dimensional functional evaluation. The Pearson Correlation and Bland-Altman analysis were performed to compare the results from the two MR methods (MR-Argus and CMR tools) and the results from both the MDCT and the 2DE with the CMR tools results. Strong positive correlations for EF values were found between the MDCT and CMR tools (r=0.702 p<0.001), and between the MR-Argus and CMR tools (r=0.746 p<0.001). The correlation between the 2DE and CMR tools (r=0.449 p<0.004), however, was only moderate. Similar results were obtained for the other parameters. The strongest correlation for ESV, EDV, and EF was between the two MR software programs. The correlation coefficient between the MDCT and CMR tools is close to the correlation coefficient between the two software programs. While the correlation between 2DE and CMR tools was satisfactory for ESV, EDV, and CO values, it was at a moderate level for the other parameters. Left ventricular functional analysis

  7. Radionuclide angiographical assessment of the effects of aorto-coronary bypass grafting on ventricular function during rest and exercise

    International Nuclear Information System (INIS)

    Kito, Yoshitsugu; Fujita, Tsuyoshi; Ohara, Kuniyoshi

    1983-01-01

    Ventricular function was measured by radionuclide angiography during rest and exercise in 27 patients before and after aorto-coronary bypass grafting (AC bypass). The patients were divided in three groups: 6 patients in complete revascularisation (group A), 8 patients in surgical complete revascularisation (group B), and 13 patients in incomplete revascularisation (group C). Heart rate increased by exercise from 58 +- 5 bpm to 87 +- 5 bpm, from 60 +- 5 bpm to 90 +- 15 bpm, and from 61 +- 8 bpm to 84 +- 7 bpm before AC bypass, and increased from 81 +- 7 bpm to 116 +- 11 bpm, from 86 +- 13 bpm to 114 +- 12 bpm, and from 80 +- 11 bpm to 106 +- 13 bpm after AC bypass in group A, B and C, respecitively. EF decreased by exercise from 61 +- 7 % to 58 +- 12 %, from 53 +- 10 % to 49 +- 7 %, and from 54 +- 8 % to 52 +- 8 % before AC bypass, and increased by exercise from 66 +- 7 % to 77 +- 6 %, from 49 +- 11 % to 56 +- 13 %, and from 54 +- 8 % to 59 +- 10 % after AC bypass in group A,FB and C, respectively. dV/dt(Vmax/sec) increased by exercise from 4.0 +- 1.0 to 4.4 +- 1.0, from 2.5 +- 1.0 to 3.4 +- 1.5 and from 3.5 +- 0.5 to 3.4 +- 0.6 before AC bypass, and increased from 3.9 +- 0.5 to 6.2 +- 0.7, from 3.5 +- 0.9 to 5.0 +- 0.7, and from 3.6 +- 1.0 to 5.4 +- 1.5 after AC bypass in group A,B and C, respectively. In conclusion, left ventricular performance during exercise was significantly increased after AC bypass in all patients. However, the rate of increase in left ventricular performance during exercise after AC bypass was more significant in the group of complete revascularisation than in the group of others. Serial application of radionuclide angiography to patients after AC bypass appears promising in evaluating the long-term effects of operation on ventricular function. (author)

  8. The influence of percutaneous closure of patent ductus arteriosus on left ventricular size and function: a prospective study using two- and three-dimensional echocardiography and measurements of serum natriuretic peptides.

    Science.gov (United States)

    Eerola, Anneli; Jokinen, Eero; Boldt, Talvikki; Pihkala, Jaana

    2006-03-07

    We aimed to evaluate the effect of percutaneous closure of patent ductus arteriosus (PDA) on left ventricular (LV) hemodynamics. Today, most PDAs are closed percutaneously. Little is known, however, about hemodynamic changes after the procedure. Of 37 children (ages 0.6 to 10.6 years) taken to the catheterization laboratory for percutaneous PDA closure, the PDA was closed in 33. Left ventricular diastolic and systolic dimensions, volumes, and function were examined by two-dimensional (2D) and three-dimensional (3D) echocardiography and serum concentrations of natriuretic peptides measured before PDA closure, on the following day, and 6 months thereafter. Control subjects comprised 36 healthy children of comparable ages. At baseline, LV diastolic diameter measured >+2 SD in 5 of 33 patients. In 3D echocardiography, a median LV diastolic volume measured 54.0 ml/m2 in the control subjects and 58.4 ml/m2 (p closure and 57.2 ml/m2 (p = NS) 6 months after closure. A median N-terminal brain natriuretic peptide (pro-BNP) concentration measured 72 ng/l in the control group and 141 ng/l in the PDA group before closure (p = 0.001) and 78.5 ng/l (p = NS) 6 months after closure. Patients differed from control subjects in indices of LV systolic and diastolic function at baseline. By the end of follow-up, all these differences had disappeared. Even in the subgroup of patients with normal-sized LV at baseline, the LV diastolic volume decreased significantly during follow-up. Changes in LV volume and function caused by PDA disappear by 6 months after percutaneous closure. Even the children with normal-sized LV benefit from the procedure.

  9. CT assessment of normal splenic size in children

    International Nuclear Information System (INIS)

    Prassopoulos, P.; Cavouras, D.

    1994-01-01

    The size of the normal spleen was estimated by CT in 153 children, examined with indication unrelated to splenic disease. In each patient the width, thickness, length and volume of the spleen were calculated. Measurements were also normalized to the transverse diameter of the body of the first lumbar vertebra. The spleen underwent significant growth during the first 4 years of life and reached maximum size at the age of 13. There were no differences in splenic volume between boys and girls. Splenic thickness correlated best with normal splenic volume. The strongest correlation was also found between splenic thickness and volume in a group of 45 children with clinically evident splenomegaly. Splenic thickness, an easy-to-use measurement, may be employed in everyday practice to represent splenic volume on CT. (orig.)

  10. The value of right ventricular longitudinal strain in the evaluation of adult patients with repaired tetralogy of Fallot: a new tool for a contemporary challenge.

    Science.gov (United States)

    Almeida-Morais, Luís; Pereira-da-Silva, Tiago; Branco, Luísa; Timóteo, Ana T; Agapito, Ana; de Sousa, Lídia; Oliveira, José A; Thomas, Boban; Jalles-Tavares, Nuno; Soares, Rui; Galrinho, Ana; Cruz-Ferreira, Rui

    2017-04-01

    The role of right ventricular longitudinal strain for assessing patients with repaired tetralogy of Fallot is not fully understood. In this study, we aimed to evaluate its relation with other structural and functional parameters in these patients. Patients followed-up in a grown-up CHD unit, assessed by transthoracic echocardiography, cardiac MRI, and treadmill exercise testing, were retrospectively evaluated. Right ventricular size and function and pulmonary regurgitation severity were assessed by echocardiography and MRI. Right ventricular longitudinal strain was evaluated in the four-chamber view using the standard semiautomatic method. In total, 42 patients were included (61% male, 32±8 years). The mean right ventricular longitudinal strain was -16.2±3.7%, and the right ventricular ejection fraction, measured by MRI, was 42.9±7.2%. Longitudinal strain showed linear correlation with tricuspid annular systolic excursion (r=-0.40) and right ventricular ejection fraction (r=-0.45) (all ptetralogy of Fallot. It correlated with echocardiographic right ventricular function parameters and was independently associated with right ventricular ejection fraction derived by MRI.

  11. Assessment of Nugget Size of Spot Weld using Neutron Radiography

    Directory of Open Access Journals (Sweden)

    Triyono

    2011-08-01

    Full Text Available Resistance spot welding (RSW has been widely used for many years in the fabrication of car body structures, mainly due to the cost and time considerations. The weld quality as well as the nugget size is an issue in various manufacturing and processes due to the strong link between the weld quality and safety. It has led to the development of various destructive and non-destructive tests for spot welding such as peel testing, ultrasonic inspections, digital shearography, and infrared thermography. However, such methods cannot show spot weld nugget visually and the results are very operator’s skill dependent. The present work proposes a method to visualize the nugget size of spot welds using neutron radiography. Water, oil and various concentrations of gadolinium oxide-alcohol mixture were evaluated as a contrast media to obtain the best quality of radiography. Results show that mixture of 5 g gadolinium oxide (Gd2O3 in 25 ml alcohol produces the best contrast. It provides the possibility to visualize the shape and size of the nugget spot weld. Furthermore, it can discriminate between nugget and corona bond. The result of neutron radiography evaluation shows reasonable agreement with that of destructive test.

  12. Assessment of pathophysiology based on the left ventricular shape in five patients with midventricular obstructive hypertrophic cardiomyopathy

    International Nuclear Information System (INIS)

    Aoki, Mayumi; Uekita, Kazumi; Obata, Hiromi; Makiguchi, Noriko; Mitsuoka, Takao; Kikuchi, Kenjiro

    2007-01-01

    The pathophysiology of midventricular obstructive hypertrophic cardiomyopathy (MVO) is unknown. Patients with MVO and MVO-like cardiomyopathy were classified into three groups based on the cardioimaging morphological characteristics of the left ventricle to investigate their complications and treatment. Four patients with MVO and one patient with disease-like MVO were admitted in our hospital from 1999 to 2005. Group A consisted of one patient with indications of pressure gradient at mid-ventricle without apical aneurysm, Group B consisted of three patients with indications of pressure gradient and apical aneurysm, and Group C consisted of one patient with hour-glass appearance with apical aneurysm and decreased left ventricular systolic function without pressure gradient. The diagnosis was established during examination for sustained ventricular tachycardia (SVT, three patients), paroxysmal atrial fibrillation (one patient), and coronary artery disease (one patient). Cardiogenic embolization was observed in all cases which originated from atrial fibrillation (one case) and apical aneurysm (two cases). No embolic event occurred in any patient after warfarin therapy. SVT occurred in patients in Groups B and C. SVT refractory to beta-blocker and mexiletine was treated by amiodarone. Apical aneurysmectomy and cryoablation could prevent recurrent SVT with drug resistance. Four of the five patients with MVO had arrhythmia (atrial fibrillation, SVT) and three had cardiogenic embolization. MVO could be classified into three groups depending on the morphological characteristics and complications. Treatment of MVO should be based on these characteristics. (author)

  13. Phase analysis of gated blood pool SPECT for multiple stress testing assessments of ventricular mechanical dyssynchrony in a tachycardia-induced dilated cardiomyopathy canine model.

    Science.gov (United States)

    Salimian, Samaneh; Thibault, Bernard; Finnerty, Vincent; Grégoire, Jean; Harel, François

    2017-02-01

    Stress-induced dyssynchrony has been shown to be independently correlated with clinical outcomes in patients with dilated cardiomyopathy (DCM) and narrow QRS complexes. However, the extent to which stress levels affect inter- and intraventricular dyssynchrony parameters remains unknown. Ten large dogs were submitted to tachycardia-induced DCM by pacing the right ventricular apex for 3-4 weeks to reach a target ejection fraction (EF) of 35% or less. Stress was then induced in DCM dogs by administering intravenous dobutamine up to a maximum of 20 μg·kg -1 ·min -1 . Hemodynamic and ventricular dyssynchrony data were analyzed by left ventricular (LV) pressure measurements and gated blood pool SPECT (GBPS) imaging. In order to assess mechanical dyssynchrony in DCM subjects and compare it with that of 8 normal counterparts, we extracted the following data: count-based indices of LV contraction homogeneity index (CHI), entropy and phase standard deviation, and interventricular dyssynchrony index. A significant LV intraventricular dyssynchrony (CHI: 96.4 ± 1.3% in control vs 78.6% ± 10.9% in DCM subjects) resulted in an intense LV dysfunction in DCM subjects (EF: 49.5% ± 8.4% in control vs 22.6% ± 6.0% in DCM), compared to control subjects. However, interventricular dyssynchrony did not vary significantly between the two groups. Under stress, DCM subjects showed a significant improvement in ventricular functional parameters at each level (EF: 22.6% ± 6.0% at rest vs 48.1% ± 5.8% at maximum stress). All intraventricular dyssynchrony indices showed a significant increase in magnitude of synchrony from baseline to stress levels of greater than or equal to 5 μg·kg -1 ·min -1 dobutamine. There were individual differences in the magnitude and pattern of change in interventricular dyssynchrony during the various levels of stress. Based on GBPS analyses, different levels of functional stress, even in close intervals, can have a significant impact on

  14. Assessment value of 3-dimensional speckle tracking imaging for changes of early left ventricular longitudinal systolic function in patients with primary hypertension

    Directory of Open Access Journals (Sweden)

    Jing Yu

    2016-08-01

    Full Text Available Objective: To study the assessment value of 3-dimensional speckle tracking imaging for changes of early left ventricular longitudinal systolic function in patients with primary hypertension. Methods: Patients with primary hypertension who were treated in our hospital from May 2012 to October 2015 were selected, and 40 patients with left ventricular normal (LVN primary hypertension and 40 patients with left ventricular remodeling (LVR primary hypertension were screened according to Ganau typing and enrolled in the LVN group and LVR group of the study respectively; 40 cases of healthy volunteers who received physical examination in our hospital during the same period were selected as control group. Ultrasonic testing was conducted to determine conventional ultrasonic indicators and 3D-STI parameters, and serum was collected to determine AngII, ALD, TGF-β1 and Ang1-7 levels. Results: LVEDd, LVPWT and LVEF of LVN group were not significantly different from those of control group, LVEF of LVR group was not significantly different from those of LVN group and control group, and LVEDd and LVPWT of LVR group were significantly higher than those of LVN group and control group; absolute values of GLS, GCS, GRS and GAS as well as serum Ang1-7 level of LVN group was significantly lower than those of control group, serum AngII, ALD and TGF-β1 levels were higher than those of control group, absolute values of GLS, GCS, GRS and GAS as well as serum Ang1-7 level of LVR group was significantly lower than those of LVN group and control group, and serum AngII, ALD and TGF-β1 levels were higher than those of LVN group and control group; absolute values of GLS, GCS, GRS and GAS were negatively correlated with serum AngII, ALD and TGF-β1 levels, and positively correlated with serum Ang1-7 level. Conclusion: 3-dimensional speckle tracking imaging can be used for early evaluation of left ventricular longitudinal systolic function in patients with primary

  15. Use of a simple intraoperative hydrostatic pressure test to assess the relationship between mobility of the ventricular stoma and success of third ventriculostomy.

    LENUS (Irish Health Repository)

    Kamel, Mahmoud Hamdy

    2012-02-03

    OBJECT: Neuroendoscopists often note pulsatility or flabbiness of the floor of the third ventricle during endoscopic third ventriculostomy (ETV) and believe that either is a good indication of the procedure\\'s success. Note, however, that this belief has never been objectively measured or proven in a prospective study. The authors report on a simple test-the hydrostatic test-to assess the mobility of the floor of the third ventricle and confirm adequate ventricular flow. They also analyzed the relationship between a mobile floor (a positive hydrostatic test) and prospective success of ETV. METHODS: During a period of 3 years between July 2001 and July 2004, 30 ETVs for obstructive hydrocephalus were performed in 22 male and eight female patients. Once the stoma had been created, the irrigating Ringer lactate solution was set at a 30-cm height from the external auditory meatus, and the irrigation valve was opened while the other ports on the endoscope were closed. The ventricular floor ballooned downward and stabilized. The irrigation valve was then closed and ports of the endoscope were opened. The magnitude of the upward displacement of the floor was then assessed. Funneling of the stoma was deemed to be a good indicator of floor mobility, adequate flow, and a positive hydrostatic test. All endoscopic procedures were recorded using digital video and recordings were subsequently assessed separately by two blinded experienced neuroendoscopists. Patients underwent prospective clinical follow up during a mean period of 11.2 months (range 1 month-3 years), computerized tomography and\\/or magnetic resonance imaging studies of the brain, and measurements of cerebrospinal fluid pressure through a ventricular reservoir when present. Failure of ETV was defined as the subsequent need for shunt implantation. The overall success rate of the ETV was 70% and varied from 86.9% in patients with a mobile stoma and a positive hydrostatic test to only 14.2% in patients with a

  16. Assessment of breast tumor size in electrical impedance scanning

    International Nuclear Information System (INIS)

    Kim, Sungwhan

    2012-01-01

    Electrical impedance scanning (EIS) is a newly introduced imaging technique for early breast cancer detection. In EIS, we apply a sinusoidal voltage between a hand-held electrode and a scanning probe placed on the breast skin to make current travel through the breast. We measure induced currents (Neumann data) through the scanning probe. In this paper, we investigate the frequency-dependent behavior of the induced complex potential and show how the frequency differential of the current measurement on the scanning probe reflects the contrast in complex conductivity values between surrounding and cancerous tissues. Furthermore, we develop the formula for breast tumor size using the frequency differential of the current measurement and provide its feasibility. (paper)

  17. Assessment of Competence in EVAR Stent Graft Sizing and Selection

    DEFF Research Database (Denmark)

    Strøm, M; Lönn, L.; Bech, B.

    2017-01-01

    Objectives and background: The aims of this study were to develop a test of competence in endovascular aortic repair (EVAR) stent graft sizing and selection; to examine the test for evidence of validity; and to explore the experience required for the task. Methods: The test was developed based...... measurements, Mann-Whitney U test could discriminate between experts and novices (p = .002), between experts and intermediates (p = .010), and between novices and intermediates (p = .036). In stent selection the experts performed significantly better than both the novices and the intermediates (p = .002 and p...... of competence in vessel analysis and stent graft selection for endovascular aortic repair. This was supported by strong validity evidence with good internal consistency and discriminatory ability. The tool may be used to facilitate training and certification of future endovascular specialists....

  18. The full size validation of remanent life assessment methods

    International Nuclear Information System (INIS)

    Hepworth, J.K.; Williams, J.A.

    1988-03-01

    A range of possible life assessment techniques for the remanent life appraisal of creeping structures is available in the published literature. However, due to the safety implications, the true conservatism of such methods cannot be assessed on operating plant. Consequently, the CEGB set up a four vessel programme in the Pressure Vessel Test Facility at the Marchwood Engineering Laboratories of the CEGB to underwrite and quantify the accuracy of these methods. The application of two non-destructive methods, namely strain monitoring and hardness measurement, to the data generated during about 12,000 hours of testing is examined. The current state of development of these methods is reviewed. Finally, the future CEGB programme relating to these vessels is discussed. (author)

  19. The left ventricle as a mechanical engine: from Leonardo da Vinci to the echocardiographic assessment of peak power output-to-left ventricular mass.

    Science.gov (United States)

    Dini, Frank L; Guarini, Giacinta; Ballo, Piercarlo; Carluccio, Erberto; Maiello, Maria; Capozza, Paola; Innelli, Pasquale; Rosa, Gian M; Palmiero, Pasquale; Galderisi, Maurizio; Razzolini, Renato; Nodari, Savina

    2013-03-01

    The interpretation of the heart as a mechanical engine dates back to the teachings of Leonardo da Vinci, who was the first to apply the laws of mechanics to the function of the heart. Similar to any mechanical engine, whose performance is proportional to the power generated with respect to weight, the left ventricle can be viewed as a power generator whose performance can be related to left ventricular mass. Stress echocardiography may provide valuable information on the relationship between cardiac performance and recruited left ventricular mass that may be used in distinguishing between adaptive and maladaptive left ventricular remodeling. Peak power output-to-mass, obtained during exercise or pharmacological stress echocardiography, is a measure that reflects the number of watts that are developed by 100 g of left ventricular mass under maximal stimulation. Power output-to-mass may be calculated as left ventricular power output per 100 g of left ventricular mass: 100× left ventricular power output divided by left ventricular mass (W/100 g). A simplified formula to calculate power output-to-mass is as follows: 0.222 × cardiac output (l/min) × mean blood pressure (mmHg)/left ventricular mass (g). When the integrity of myocardial structure is compromised, a mismatch becomes apparent between maximal cardiac power output and left ventricular mass; when this occurs, a reduction of the peak power output-to-mass index is observed.

  20. Assessment of tenascin-C levels in ventricular noncompaction/hypertrabeculation patients: a cross-sectional study.

    Science.gov (United States)

    Erer, Hatice Betul; Guvenc, Tolga Sinan; Kemik, Ahu Sarbay; Yilmaz, Hale; Kul, Seref; Altay, Servet; Oz, Dilaver; Zeren, Gonul; Ekmekci, Ahmet; Zencirci, Aycan Esen; Sayar, Nurten; Eren, Mehmet

    2014-02-01

    Ventricular noncompaction/hypertrabeculation (NC/HT) is a rare form of congenital cardiomyopathy. We aimed to investigate the presence of serum tenascin-C (TN-C) in adult patients with NC/HT and evaluate its value. Serum TN-C levels were measured by ELISA in 50 NC/HT patients both with/without systolic dysfunction and in 23 normal controls. Systolic dysfunction was defined as ejection fraction (EF) ≤ 40. Mann-Whitney U-test and ROC curve analysis were done. Of 49 NC/HT patients, 24 (49%) patients had systolic dysfunction (mean age 36 ± 15) and 25 patients (51%) had normal systolic function (mean age 36 ± 17). The ages between groups were not different. The mean levels of serum TN-C in patients with or without systolic dysfunction were 26 ± 10 ng/mL and 26 ± 8 ng/mL respectively, compared to normal controls, 7 ± 2 ng/mL (P < 0.001). No significance was observed between 2 groups of NC/HT patients regarding TN-C levels (P = 0.8). The ROC curve analysis revealed that a TN-C value of 11.7 ng/mL identified patients with NC/HT with 100% sensitivity and specifity. High serum TN-C levels are present in adult NC/HT cardiomyopathy even when left ventricular systolic function remains normal. Also, serum TN-C levels could be regarded as a candidate biomarker in the diagnosis of NC/HT which needs to be tested in larger prospective studies. © 2013, Wiley Periodicals, Inc.

  1. Importance of ventricular rate after mode switching during low intensity exercise as assessed by clinical symptoms and ventilatory gas exchange.

    Science.gov (United States)

    Brunner-La Rocca, H P; Rickli, H; Weilenmann, D; Duru, F; Candinas, R

    2000-01-01

    Automatic mode switching from DDD(R) to DDI(R) or VVI(R) pacing modes has improved dual chamber pacing in patients at high risk for supraventricular tachyarrhythmias. However, little is known about the effect of ventricular pacing rate adaptation after mode switching. We conducted a single-blinded, crossover study in 15 patients (58 +/- 21 years) with a DDD pacemaker who had AV block and normal sinus node function to investigate the influence of pacing rate adaptation to intrinsic heart rate during low intensity exercise. Patients performed two tests (A/B) of low intensity treadmill exercise (0.5 W/kg) in randomized order. They initially walked for 6 minutes while paced in DDD mode. The pacing mode was then switched to VVI with a pacing rate of either 70 beats/min (test A) or matched to the intrinsic heart rate (95 +/- 11 beats/min test B). Respiratory gas exchange variables were determined and patients classified the effort before and after mode switching on a Borg scale from 6 to 20. Percentage changes of respiratory gas exchange measurements were significantly larger (O2 consumption: -8.2 +/- 5.0% vs. -0.6 +/- 7.2%; ventilatory equivalent of CO2 exhalation: 5.3 +/- 4.9% vs. 1.5 +/- 4.3%; respiratory exchange ratio: 7.0 +/- 2.2% vs. 3.5 +/- 3.0%; end-tidal CO2: -5.7 +/- 2.9% vs. -1.8 +/- 2.7%; all P rate unadjusted than after adjusted mode switching. Mode switching from DDD to VVI pacing is better tolerated and gas exchange measurements are less influenced if ventricular pacing rate is adjusted to the level of physical activity. Thus, pacing rate adjustment should be considered as part of automatic mode switch algorithms.

  2. Left ventricular dyssynchrony assessed by gated SPECT phase analysis is an independent predictor of death in patients with advanced coronary artery disease and reduced left ventricular function not undergoing cardiac resynchronization therapy

    Energy Technology Data Exchange (ETDEWEB)

    Uebleis, Christopher; Hellweger, Stefan; Lehner, Sebastian; Haug, Alexander; Bartenstein, Peter; Cumming, Paul; Hacker, Marcus [Ludwig-Maximilians University, Department of Nuclear Medicine, Munich (Germany); Laubender, Ruediger Paul [Ludwig-Maximilians University, Institute of Medical Informatics, Biometry, and Epidemiology (IBE), Munich (Germany); Becker, Alexander [Ludwig-Maximilians University, Medical Department I, Munich (Germany); Sohn, Hae-Young [Ludwig-Maximilians University, Medical Department Innenstadt, Munich (Germany); Van Kriekinge, Serge D.; Slomka, Piotr J. [Cedars-Sinai Medical Center, Los Angeles, CA (United States); UCLA, David Geffen School of Medicine, Los Angeles, CA (United States)

    2012-10-15

    Left ventricular (LV) mechanical dyssynchrony (LVMD) was assessed by gated single-photon emission CT myocardial perfusion imaging (MPI) as an independent predictor of death from any cause in patients with known coronary artery disease (CAD) and reduced LV function. Between 2001 and 2010, 135 patients (64 {+-} 11 years of age, 84 % men) with known CAD, reduced LV ejection fraction (LVEF, 38 {+-} 15 %) and without an implanted cardiac resynchronization therapy device underwent gated MPI at rest. LV functional evaluation, which included phase analysis, was conducted to identify patients with LVMD. Kaplan-Meier survival curves were calculated for death of any cause during a mean follow-up of 2.0 {+-} 1.7 years. Uni- and multivariate Cox proportional hazards regression models were calculated to identify independent predictors of death from any cause. Of the 135 patients, 30 (22 %) died during follow-up (18 cardiac deaths and 12 deaths from other causes). Kaplan-Meier curves showed a significantly shorter survival time in the patients with severely reduced LVEF (<30 %, n = 45) or with LVMD (n = 81, log-rank test P <0.005). Cox models identified LVMD, LVEF <30 % and a total perfusion deficit at rest of {>=}20 % as independent predictors of death from any cause. While patients with LVEF <30 % in conjunction with LVMD had similar survival times irrespective of whether they had early revascularization or medical therapy, those patients with LVEF {>=}30% and LVMD who underwent revascularization had significantly longer survival. In patients with known CAD and reduced LV function, dyssynchrony of the LV is an independent predictor of death from any cause. (orig.)

  3. Shear-wave elastography contributes to accurate tumour size estimation when assessing small breast cancers

    International Nuclear Information System (INIS)

    Mullen, R.; Thompson, J.M.; Moussa, O.; Vinnicombe, S.; Evans, A.

    2014-01-01

    Aim: To assess whether the size of peritumoural stiffness (PTS) on shear-wave elastography (SWE) for small primary breast cancers (≤15 mm) was associated with size discrepancies between grey-scale ultrasound (GSUS) and final histological size and whether the addition of PTS size to GSUS size might result in more accurate tumour size estimation when compared to final histological size. Materials and methods: A retrospective analysis of 86 consecutive patients between August 2011 and February 2013 who underwent breast-conserving surgery for tumours of size ≤15 mm at ultrasound was carried out. The size of PTS stiffness was compared to mean GSUS size, mean histological size, and the extent of size discrepancy between GSUS and histology. PTS size and GSUS were combined and compared to the final histological size. Results: PTS of >3 mm was associated with a larger mean final histological size (16 versus 11.3 mm, p < 0.001). PTS size of >3 mm was associated with a higher frequency of underestimation of final histological size by GSUS of >5 mm (63% versus 18%, p < 0.001). The combination of PTS and GSUS size led to accurate estimation of the final histological size (p = 0.03). The size of PTS was not associated with margin involvement (p = 0.27). Conclusion: PTS extending beyond 3 mm from the grey-scale abnormality is significantly associated with underestimation of tumour size of >5 mm for small invasive breast cancers. Taking into account the size of PTS also led to accurate estimation of the final histological size. Further studies are required to assess the relationship of the extent of SWE stiffness and margin status. - Highlights: • Peritumoural stiffness of greater than 3 mm was associated with larger tumour size. • Underestimation of tumour size by ultrasound was associated with peri-tumoural stiffness size. • Combining peri-tumoural stiffness size to ultrasound produced accurate tumour size estimation

  4. Assessment of left ventricular function and mass by MR imaging: a stereological study based on the systematic slice sampling procedure.

    Science.gov (United States)

    Mazonakis, Michalis; Sahin, Bunyamin; Pagonidis, Konstantin; Damilakis, John

    2011-06-01

    The aim of this study was to combine the stereological technique with magnetic resonance (MR) imaging data for the volumetric and functional analysis of the left ventricle (LV). Cardiac MR examinations were performed in 13 consecutive subjects with known or suspected coronary artery disease. The end-diastolic volume (EDV), end-systolic volume, ejection fraction (EF), and mass were estimated by stereology using the entire slice set depicting LV and systematic sampling intensities of 1/2 and 1/3 that provided samples with every second and third slice, respectively. The repeatability of stereology was evaluated. Stereological assessments were compared with the reference values derived by manually tracing the endocardial and epicardial contours on MR images. Stereological EDV and EF estimations obtained by the 1/3 systematic sampling scheme were significantly different from those by manual delineation (P sampling intensity of 1/2 (P > .05). For these stereological approaches, a high correlation (r(2) = 0.80-0.93) and clinically acceptable limits of agreement were found with the reference method. Stereological estimations obtained by both sample sizes presented comparable coefficient of variation values of 2.9-5.8%. The mean time for stereological measurements on the entire slice set was 3.4 ± 0.6 minutes and it was reduced to 2.5 ± 0.5 minutes with the 1/2 systematic sampling scheme. Stereological analysis on systematic samples of MR slices generated by the 1/2 sampling intensity provided efficient and quick assessment of LV volumes, function, and mass. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  5. Factors of Formation of Various Types of Left Ventricular Diastolic Filling in Adolescents with Myocardium Pathology

    Directory of Open Access Journals (Sweden)

    L.F. Bogmat

    2016-08-01

    Full Text Available Objective: to study the main components of the formation of impaired left ventricular diastolic filling in adolescents with myocardial pathology. Materials and methods. The study involved 110 adolescents with myocardial pathology aged 13–18 years, of which 40 — with heart rhythm disorder, 40 — with dysplastic cardiomyopathy, 30 — with primary hypertension. Morphological and functional parameters of the heart were studied using ultrasound according to standard procedure. Left ventricular diastolic function has been studied in the pulsed wave Doppler mode with transmitral flow mapping from the apical access of four-chambered heart. For an adequate assessment of left ventricular diastolic function and detection of its earliest disorders, adolescents underwent tests with isometric exercise. Based on these results, adolescents were divided in terms of the E/A ratio. In order to identify common latent factors that explain the correlation between indicators, we have used the factor analysis, namely, the principal component analysis. All statistical procedures were performed using application packages Statgraphics Centurion. Results. On the initial stages of formation of diastolic dysfunction of the left ventricular myocardium in adolescents, a significant role is played by a number of factors, which can be conditionally defined as the geometric, functional and neurohumoral factors consistently included in the pathological process. Thus, during the formation of left ventricular diastolic dysfunction type 1, the number one is neurohumoral factor, namely, the activation of the sympathoadrenal system, then peripheral vascular tone is being involved in the pathological process, and, consequently, a geometric factor — changing the sizes of the left atrium. In the formation of left ventricular diastolic dysfunction type 2, the process consistently involves the renin-angiotensin system, namely, renin, a functional factor is presented by the indices

  6. Echocardiographic left ventricular masses in distance runners and weight lifters

    Science.gov (United States)

    Longhurst, J. C.; Gonyea, W. J.; Mitchell, J. H.; Kelly, A. R.

    1980-01-01

    The relationships of different forms of exercise training to left ventricular mass and body mass are investigated by echocardiographic studies of weight lifters, long-distance runners, and comparatively sized untrained control subjects. Left ventricular mass determinations by the Penn convention reveal increased absolute left ventricular masses in long-distance runners and competitive weight lifters with respect to controls matched for age, body weight, and body surface area, and a significant correlation between ventricular mass and lean body mass. When normalized to lean body mass, the ventricular masses of distance runners are found to be significantly higher than those of the other groups, suggesting that dynamic training elevates left ventricular mass compared to static training and no training, while static training increases ventricular mass only to the extent that lean body mass is increased.

  7. Assessment of right ventricular oxidative metabolism by PET in patients with idiopathic dilated cardiomyopathy undergoing cardiac resynchronisation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Knuuti, Juhani; Naum, Alexandru; Stolen, Kira Q.; Kalliokoski, Riikka [University of Turku, Turku PET Centre, P.O. Box 52, Turku (Finland); Sundell, Jan [University of Turku, Turku PET Centre, P.O. Box 52, Turku (Finland); University of Turku, Department of Medicine, Turku (Finland); Engblom, Erik; Koistinen, Juhani; Airaksinen, K.E. Juhani [University of Turku, Department of Medicine, Turku (Finland); Ylitalo, Antti [Satakunta Central Hospital, Department of Medicine, Pori (Finland); Nekolla, Stephan G. [Klinikum rechts der Isar der Technischen Universitaet Muenchen, Klinik und Poliklinik fuer Nuklearmedizin, Munich (Germany); Bax, K.E. Jeroen J. [Leiden University, Department of Cardiology, Leiden (Netherlands)

    2004-12-01

    Right ventricular (RV) performance is known to have prognostic value in patients with congestive heart failure (CHF). Cardiac resynchronisation therapy (CRT) has been found to enhance left ventricular (LV) energetics and metabolic reserve in patients with heart failure. The interplay between the LV and RV may play an important role in CRT response. The purpose of the study was to investigate RV oxidative metabolism, metabolic reserve and the effects of CRT in patients with CHF and left bundle brach block. In addition, the role of the RV in the response to CRT was evaluated. Ten patients with idiopathic dilated cardiomyopathy who had undergone implantation of a biventricular pacemaker 8{+-}5 months earlier were studied under two conditions: CRT ON and after CRT had been switched OFF for 24 h. Oxidative metabolism was measured using [{sup 11}C]acetate positron emission tomography (K{sub mono}). The measurements were performed at rest and during dobutamine-induced stress (5 {mu}g/kg per minute). LV performance and interventricular mechanical delay (interventricular asynchrony) were measured using echocardiography. CRT had no effect on RV K{sub mono} at rest (ON: 0.052{+-}0.014, OFF: 0.047{+-}0.018, NS). Dobutamine-induced stress increased RV K{sub mono} significantly under both conditions but oxidative metabolism was more enhanced when CRT was ON (0.076{+-}0.026 vs 0.065{+-}0.027, p=0.003). CRT shortened interventricular delay significantly (45{+-}33 vs 19{+-}35 ms, p=0.05). In five patients the response to CRT was striking (32% increase in mean LV stroke volume, range 18-36%), while in the other five patients no response was observed (mean change +2%, range -6% to +4%). RV K{sub mono} and LV stroke volume response to CRT correlated inversely (r=-0.66, p=0.034). None of the other measured parameters, including all LV parameters and electromechanical parameters, were associated with the response to CRT. In responders, RV K{sub mono} with CRT OFF was significantly lower

  8. Assessment of Diffuse Ventricular Myocardial Fibrosis Using Native T1 in Children With Repaired Tetralogy of Fallot.

    Science.gov (United States)

    Yim, Deane; Riesenkampff, Eugenie; Caro-Dominguez, Pablo; Yoo, Shi-Joon; Seed, Mike; Grosse-Wortmann, Lars

    2017-03-01

    Myocardial fibrosis is linked with adverse clinical outcomes in adults after tetralogy of Fallot repair (rTOF). Native T1 times (T1) by cardiac magnetic resonance have been shown to be a surrogate marker of diffuse myocardial fibrosis. The objective was to quantify native T1 in children post-rTOF and to evaluate their relationship with surgical, imaging, and clinical factors. A retrospective cross-sectional study was performed. Midventricular native T1 were obtained in 100 children post-rTOF using a modified look-locker inversion recovery cardiac magnetic resonance sequence and compared with 35 pediatric controls. rTOF patients, aged 13.0±2.9 years, had higher indexed right ventricular (RV) end-diastolic (range 85-326 mL/m 2 , mean 148 mL/m 2 ) volumes, and lower RV and left ventricular (LV) ejection fractions compared with controls. RV, but not LV, T1 were higher in patients than in controls (1031±74 versus 954±32 ms, P <0.001) and female patients had higher RV T1 compared with males (1051±79 versus 1017±68 ms, P =0.02). LV T1 correlated with RV T1 ( r =0.45, P <0.001), cardiopulmonary bypass ( r =0.30, P =0.007), and aortic cross-clamp times ( r =0.32, P =0.004). RV T1 correlated inversely with RV outflow tract gradient ( r =-0.28, P =0.02). Longer aortic cross-clamp times were independently associated with LV and RV T1 on multivariable analysis. There was no association between exercise intolerance, arrhythmia, and native T1 or LV extracellular volume. Children after rTOF do not have elevated LV native T1 or LV extracellular volume, but show evidence of increased RV native T1 suggestive of diffuse RV fibrosis, for which volume loading seems to be a risk factor. Surgical bypass and cross-clamp times are associated with fibrotic remodeling over a decade later. © 2017 American Heart Association, Inc.

  9. Assessment of left ventricular torsion and untwisting in patients suffering from dilated cardiomyopathy by velocity vector imaging

    Directory of Open Access Journals (Sweden)

    Xiao-juan ZHANG

    2015-10-01

    Full Text Available Objective To evaluate the characteristics of left ventricular twisting (LVtw and untwisting (LVuntw in patients with dilated cardiomyopathy (DCM. Methods Nineteen DCM patients (aged 18-82 years, mean 50.52±17.52 years, 2 females and 21 normal controls (aged 18-80 years, mean 49.05±16.94 years, 5 females were enrolled in present study. Basal and apical short axis view of two-dimensional images of left ventricle were obtained to analyze LV rotation, and the LV rotation velocity was detected by velocity vector imaging (VVI. LVtw, LVtw velocity, untwisting velocity and untwisting rate (untwR were calculated. Results The rotated degree and velocity of the basal and apical parts of LV myocardium were irregularly changed along with the cardiac cycle in the DCM group. The rotation degree and rotation velocity at the basal and apex axis decreased in DCM group compared with that in normal group, while the peak of twisting (Ptw [(6.49±1.82°] and the peak of twisting velocity (PTV [(67.84±15.60°/s] decreased significantly in DCM group. The untwR and peak of untwisting velocity (PUV were also decreased significantly in DCM patients. Conclusion The Ptw, PTV and PUV decrease significantly, and the LV untwR, impacted by the preload, is also decreased significantly in DCM patients. DOI: 10.11855/j.issn.0577-7402.2015.09.13

  10. Radionuclide left ventricular dV/dt for the assessment of cardiac function in patients with coronary disease.

    Science.gov (United States)

    Bianco, J A; Makey, D G; Laskey, W K; Shafer, R B

    1979-01-01

    To investigate potential uses of left-ventricular (LV) systolic ejection rate (LV dV/dt) in the evaluation of LV function, we examined the effect of exercise, angiotensin, and leg raising on LV ejection fraction and LV dV/dt in patients with coronary-artery disease. The following observations were made: a) LV ejection fraction and dV/dt changed proportionately, but in opposite directions, during supine exercise; b) LV ejection fraction and dV/dt decreased to a similar extent during angiotensin infusions; and c) LV ejection fraction and dV/dt were unchanged by leg raising. The changes in peak and mean LV dV/dt were similar. Regardless of the physiologic state, peak LV dV/dt occurred during the first third of systole. These data imply that in this population there were no specific advantages of LV dV/dt over LV ejection fraction in the evaluation of LV performance.

  11. Radionuclide left ventricular dV/dt for the assessment of cardiac function in patients with coronary disease

    International Nuclear Information System (INIS)

    Bianco, J.A.; Makey, D.G.; Laskey, W.K.; Shafer, R.B.

    1979-01-01

    To investigate potential uses of left-ventricular (LV) systolic ejection rate (LV dV/dt) in the evaluation of LV function, we examined the effect of exercise, angiotensin, and leg raising on LV ejection fraction and LV dV/dt in patients with coronary-artery disease. The following observations were made: (a) LV ejection fraction and dV/dt changed proportionately, but in opposite directions, during supine exercise; (b) LV ejection fraction and dV/dt decreased to a similar extent during angiotensin infusions; and (c) LV ejection fraction and dV/dt were unchanged by leg raising. The changes in peak and mean LV dV/dt were similar. Regardless of the physiologic state, peak LV dV/dt occurred during the first third of systole. These data imply that in this population there were no specific advantages of LV dV/dt over LV ejection fraction in the evaluation of LV performance

  12. Assessment of left ventricular function by electrocardiogram-gated myocardial single photon emission computed tomography using quantitative gated single photon emission computed tomography software

    International Nuclear Information System (INIS)

    Morita, Koichi; Adachi, Itaru; Konno, Masanori

    1999-01-01

    Electrocardiogram (ECG)-gated myocardial single photon emission computed tomography (SPECT) can assess left ventricular (LV) perfusion and function easily using quantitative gated SPECT (QGS) software. ECG-gated SPECT was performed in 44 patients with coronary artery disease under post-stress and resting conditions to assess the values of LV functional parameters, by comparison to LV ejection fraction derived from gated blood pool scan and myocardial characteristics. A good correlation was obtained between ejection fraction using QGS and that using cardiac blood pool scan (r=0.812). Some patients with myocardial ischemia had lower ejection fraction under post-stress compared to resting conditions, indicating post-stress LV dysfunction. LV wall motion and wall thickening were significantly impaired in ischemic and infarcted myocardium, and the degree of abnormality in the infarcted areas was greater than in the ischemia area. LV functional parameters derived using QGS were useful to assess post-stress LV dysfunction and myocardial viability. In conclusion, ECG-gated myocardial SPECT permits simultaneous quantitative assessment of myocardial perfusion and function. (author)

  13. Rest and exercise ventricular function in adults with congenital ventricular septal defects

    International Nuclear Information System (INIS)

    Jablonsky, G.; Hilton, J.D.; Liu, P.P.; Morch, J.E.; Druck, M.N.; Bar-Shlomo, B.Z.; McLaughlin, P.R.

    1983-01-01

    Rest and exercise right and left ventricular function were compared using equilibrium gated radionuclide angiography in 19 normal sedentary control subjects and 34 patients with hemodynamically documented congenital ventricular septal defect (VSD). Gated radionuclide angiography was performed at rest and during each level of graded supine bicycle exercise to fatigue. Heart rate, blood pressure, maximal work load achieved, and right and left ventricular ejection fractions were assessed. The control subjects demonstrated an increase in both the left and right ventricular ejection fractions with exercise. All study groups failed to demonstrate an increase in ejection fraction in either ventricle with exercise. Furthermore, resting left ventricular ejection fraction in Groups 2 and 3 was lower than that in the control subjects and resting right ventricular ejection fraction was lower in Group 3 versus control subjects. Thus left and right ventricular function on exercise were abnormal in patients with residual VSD as compared with control subjects; rest and exercise left ventricular ejection fractions remained abnormal despite surgical closure of VSD in the remote past; resting left and right ventricular function was abnormal in patients with Eisenmenger's complex; lifelong volume overload may be detrimental to myocardial function

  14. Left and right ventricular dyssynchrony and strains from cardiovascular magnetic resonance feature tracking do not predict deterioration of ventricular function in patients with repaired tetralogy of Fallot.

    Science.gov (United States)

    Jing, Linyuan; Wehner, Gregory J; Suever, Jonathan D; Charnigo, Richard J; Alhadad, Sudad; Stearns, Evan; Mojsejenko, Dimitri; Haggerty, Christopher M; Hickey, Kelsey; Valente, Anne Marie; Geva, Tal; Powell, Andrew J; Fornwalt, Brandon K

    2016-08-22

    Patients with repaired tetralogy of Fallot (rTOF) suffer from progressive ventricular dysfunction decades after their surgical repair. We hypothesized that measures of ventricular strain and dyssynchrony would predict deterioration of ventricular function in patients with rTOF. A database search identified all patients at a single institution with rTOF who underwent cardiovascular magnetic resonance (CMR) at least twice, >6 months apart, without intervening surgical or catheter procedures. Seven primary predictors were derived from the first CMR using a custom feature tracking algorithm: left (LV), right (RV) and inter-ventricular dyssynchrony, LV and RV peak global circumferential strains, and LV and RV peak global longitudinal strains. Three outcomes were defined, whose changes were assessed over time: RV end-diastolic volume, and RV and LV ejection fraction. Multivariate linear mixed models were fit to investigate relationships of outcomes to predictors and ten potential baseline confounders. One hundred fifty-three patients with rTOF (23 ± 14 years, 50 % male) were included. The mean follow-up duration between the first and last CMR was 2.9 ± 1.3 years. After adjustment for confounders, none of the 7 primary predictors were significantly associated with change over time in the 3 outcome variables. Only 1-17 % of the variability in the change over time in the outcome variables was explained by the baseline predictors and potential confounders. In patients with repaired tetralogy of Fallot, ventricular dyssynchrony and global strain derived from cine CMR were not significantly related to changes in ventricular size and function over time. The ability to predict deterioration in ventricular function in patients with rTOF using current methods is limited.

  15. Study of the Myocardial Contraction and Relaxation Velocities through Doppler Tissue Imaging Echocardiography: A New Alternative in the Assessment of the Segmental Ventricular Function

    Directory of Open Access Journals (Sweden)

    Silva Carlos Eduardo Suaide

    2002-01-01

    Full Text Available OBJECTIVE: Doppler tissue imaging (DTI enables the study of the velocity of contraction and relaxation of myocardial segments. We established standards for the peak velocity of the different myocardial segments of the left ventricle in systole and diastole, and correlated them with the electrocardiogram. METHODS: We studied 35 healthy individuals (27 were male with ages ranging from 12 to 59 years (32.9 ± 10.6. Systolic and diastolic peak velocities were assessed by Doppler tissue imaging in 12 segments of the left ventricle, establishing their mean values and the temporal correlation with the cardiac cycle. RESULTS: The means (and standard deviation of the peak velocities in the basal, medial, and apical regions (of the septal, anterior, lateral, and posterior left ventricle walls were respectively, in cm/s, 7.35(1.64, 5.26(1.88, and 3.33(1.58 in systole and 10.56(2.34, 7.92(2.37, and 3.98(1.64 in diastole. The mean time in which systolic peak velocity was recorded was 131.59ms (±19.12ms, and diastolic was 459.18ms (±18.13ms based on the peak of the R wave of the electrocardiogram. CONCLUSION: In healthy individuals, maximum left ventricle segment velocities decreased from the bases to the ventricular apex, with certain proportionality between contraction and relaxation (P<0.05. The use of Doppler tissue imaging may be very helpful in detecting early alterations in ventricular contraction and relaxation.

  16. Impact of system delay on infarct size, myocardial salvage index, and left ventricular function in patients with ST-segment elevation myocardial infarction

    DEFF Research Database (Denmark)

    Lønborg, Jacob Thomsen; Schoos, Mikkel Malby; Kelbæk, Henning Skov

    2012-01-01

    The association between reperfusion delay and myocardial damage has previously been assessed by evaluation of the duration from symptom onset to invasive treatment, but results have been conflicting. System delay defined as the duration from first medical contact to first balloon dilatation is less...

  17. Arrhythmogenic right ventricular cardiomyopathy in a dog : case report

    Directory of Open Access Journals (Sweden)

    A.J. Möhr

    2000-07-01

    Full Text Available An 8-month-old Labrador retriever bitch was evaluated for sudden-onset, progressive abdominal distension. Physical examination revealed an exaggerated inspiratory effort, severe ascites, bilateral jugular vein distension, and hypokinetic femoral arterial pulses. Thoracic auscultation detected tachycardia with muffled heart sounds, without audible cardiac murmurs. Thoracic radiographs identified severe right ventricular enlargement and pleural effusion. The electrocardiogram was consistent with incomplete right bundle branch block or right ventricular enlargement. Echocardiography demonstrated severe right ventricular and atrial dilation, secondary tricuspid regurgitation, and thinning and hypocontractility of the right ventricular myocardium. Left heart chamber sizes were slightly decreased, with normal left ventricular contractility. Adiagnosis of arrhythmogenic right ventricular cardiomyopathy was reached, based on the characteristic clinical, electrocardiographic, radiographic and echocardiographic findings, and the exclusion of other causes of isolated right ventricular failure. Treatment effected good control of clinical signs, until acutely decompensated congestive right heart failure led to euthanasia after 4 months. Arrhythmogenic right ventricular cardiomyopathy is a well-described clinical entity in humans, and has previously been documented in 3 male dogs. The condition is characterised by progressive fibro-adipose replacement of right ventricular myocardium, while the left ventricle usually remains unaffected. It should be considered a differential diagnosis in any young dog presented with isolated right heart failure, syncope, or unexplained ventricular tachyarrhythmias. This article reports the 1st case of arrhythmogenic right ventricular cardiomyopathy in a female dog, and highlights its echocardiographic features.

  18. Integrated Assessment of Left Ventricular Electrical Activation and Myocardial Strain Mapping in Heart Failure Patients: A Holistic Diagnostic Approach for Endocardial Cardiac Resynchronization Therapy, Ablation of Ventricular Tachycardia, and Biological Therapy.

    Science.gov (United States)

    Maffessanti, Francesco; Prinzen, Frits W; Conte, Giulio; Regoli, François; Caputo, Maria Luce; Suerder, Daniel; Moccetti, Tiziano; Faletra, Francesco; Krause, Rolf; Auricchio, Angelo

    2018-01-01

    This study sought to test the accuracy of strain measurements based on anatomo-electromechanical mapping (AEMM) measurements compared with magnetic resonance imaging (MRI) tagging, to evaluate the diagnostic value of AEMM-based strain measurements in the assessment of myocardial viability, and the additional value of AEMM over peak-to-peak local voltages. The in vivo identification of viable tissue, evaluation of mechanical contraction, and simultaneous left ventricular activation is currently achieved using multiple complementary techniques. In 33 patients, AEMM maps (NOGA XP, Biologic Delivery Systems, Division of Biosense Webster, a Johnson & Johnson Company, Irwindale, California) and MRI images (Siemens 3T, Siemens Healthcare, Erlangen, Germany) were obtained within 1 month. MRI tagging was used to determine circumferential strain (E cc ) and delayed enhancement to obtain local scar extent (%). Custom software was used to measure E cc and local area strain (LAS) from the motion field of the AEMM catheter tip. Intertechnique agreement for E cc was good (R 2  = 0.80), with nonsignificant bias (0.01 strain units) and narrow limits of agreement (-0.03 to 0.06). Scar segments showed lower absolute strain amplitudes compared with nonscar segments: E cc (median [first to third quartile]: nonscar -0.10 [-0.15 to -0.06] vs. scar -0.04 [-0.06 to -0.02]) and LAS (-0.20 [-0.27 to -0.14] vs. -0.09 [-0.14 to -0.06]). AEMM strains accurately discriminated between scar and nonscar segments, in particular LAS (area under the curve: 0.84, accuracy = 0.76), which was superior to peak-to-peak voltages (nonscar 9.5 [6.5 to 13.3] mV vs. scar 5.6 [3.4 to 8.3] mV; area under the curve: 0.75). Combination of LAS and peak-to-peak voltages resulted in 86% accuracy. An integrated AEMM approach can accurately determine local deformation and correlates with the scar extent. This approach has potential immediate application in the diagnosis, delivery of intracardiac therapies, and their

  19. Left ventricular performance at rest and during peak exercise in never-treated hypertensive female - an assessment with radionuclide ventriculography

    International Nuclear Information System (INIS)

    Topuzovic, N.; Karner, I.; Rusic, A.; Krstonosic, B.

    2002-01-01

    Aim: The aim of this study was to investigate left ventricular performance and exercise tolerance in never-treated female hypertensive patients. Materials and Methods: Seventeen female patients with newly established, uncomplicated essential hypertension (aged 25 to 57 years) were evaluated with rest-stress radionuclide gated ventriculography, and were compared to 23 age-matched normotensive female volunteers. Results: Mean blood pressure was significantly higher in patients at rest and during exercise than in controls (121±13 vs. 89±7 mm Hg, and 143±11 vs. 122±9 mm Hg, respectively, p 2 , respectively, p<0.01), while ESV was similar in both groups. Ejection fraction (EF) at rest and stress did not differ significantly (54±10 vs. 55±8%, and 70±10 vs. 66±8%, respectively), but % rise in EF during exercise was significantly higher in patients. At rest and during exercise, there were no significant difference in peak ejection rate (PER) and time to PER (TPER) between patients and controls. Patients had similar peak filling rate (PFR) at rest (2.88±0.79 vs. 2.76±0.76 EDV/s) and during exercise (5.85±1.86 vs. 6.21±1.97 EDV/s), in addition to nonsignificant difference in time to PFR (at rest 143±62 vs. 146±42 ms at rest, and 97±20 vs. 91±19 ms during exercise). Conclusion: Female patients with newly diagnosed, never-treated hypertension have preserved maximal exercise performance, systolic function and diastolic function, but they have significant enlargement of EDV and elevated cardiac output during exercise

  20. Usefulness of scoring right ventricular function for assessment of prognostic factors in patients with chronic thromboembolic pulmonary hypertension.

    Science.gov (United States)

    Kamimura, Yoshihiro; Okumura, Naoki; Adachi, Shiro; Shimokata, Shigetake; Tajima, Fumitaka; Nakano, Yoshihisa; Hirashiki, Akihiro; Murohara, Toyoaki; Kondo, Takahisa

    2018-04-27

    Right ventricular (RV) function is associated with prognosis in chronic thromboembolic pulmonary hypertension (CTEPH). This study aimed to establish an RV dysfunction score using RV echocardiographic parameters to clarify the clinical characteristics in patients with CTEPH and to compare RV dysfunction score with parameters such as World Health Organization (WHO) functional class, hemodynamics, exercise capacity, and plasma BNP level. We enrolled 35 inpatients with CTEPH (mean age, 62 ± 15 years, 15 males). We constructed 'an RV dysfunction score' calculated as the summation of each point awarded for the presence of four parameters: tricuspid annular plane systolic excursion (TAPSE)  0.4, 1 point. TAPSE, S', RVFAC, and RV-MPI was 18.7 ± 4.8 mm, 11.9 ± 3.1 cm/s, 33.5 ± 13.9%, and 0.39 ± 0.2, respectively. The RV dysfunction score was associated with symptom [WHO functional class (p = 0.026)], hemodynamics [mean PAP (p = 0.01), cardiac index (p = 0.009), pulmonary vascular resistance (p = 0.001), and SvO 2 (p = 0.039)], exercise capacity [6-min walk distance (p = 0.046), peakVO 2 (p = 0.016), and VE/VCO 2 slope (p = 0.031)], and plasma BNP level (p = 0.005). This RV dysfunction score using the four RV echocardiographic parameters could be a simple and useful scoring system to evaluate prognostic factors in patients with CTEPH.

  1. Assessment of automatic quantification of myocardial perfusion and left ventricular function derived from ECG gated myocardial SPECT with {sup 99m}Tc-tetrofosmin in ischemic heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Abe, Mitsunori; Habara, Hirokazu; Tatsuno, Hironari; Fukuda, Hiroshi; Hamada, Noriko; Kazatani, Yukio [Ehime Prefectural Central Hospital (Japan)

    1999-09-01

    Non-invasive assessment of ischemic heart disease (IHD) requires information of both myocardial perfusion and left ventricular (LV) function. Recently, automatic quantification of ECG-gated myocardial scintigraphy with {sup 99m}Tc-tetrofosmin (QGS) can provide both of them. QGS, coronary angiograms (CAG) and left venticulograms (LVG) were performed in 83 patients with severe IHD in same period. Significant stenosis of coronary artery in CAG were assessed by QGS. The sensitivity, specificity and accuracy of significant stenosis by QGS was excellent (85%, 93% and 88%). The LV end-distolic and end-systolic volumes (EDV and ESV), LV ejection fraction (EF) and regional LV wall motion determined by QGS were compared to LVG. There was a good correlation between the values obtained from QGS and LVG (EDV: r=0.86, ESV: r=0.94, EF: r=0.84, p<0.0001), but QGS tended to underestimate EDV and EF. High complete agreement of regional LV wall motion was gained with 427 (74.0%) out of total 581 segments. In conclusion, QGS data was considered to be useful for assessment of determine significant stenosis and LV function in severe IHD. (author)

  2. Grain Size Data from the NOAA Outer Continental Shelf Environmental Assessment Program (OCSEAP)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains grain size data from samples acquired under the NOAA Outer Continental Shelf Environmental Assessment Program (OCSEAP) from the Outer...

  3. Lone ventricular cardiomyopathy,

    African Journals Online (AJOL)

    ... (I) cardiac catheterisation, including coronary arteriography and pulmonary ... described existence of lone ventricular idiopathic ... spectrum of classic idiopathic dilated cardiomyopathy. ... endomyocardial fibrosis, and from discussions at an.

  4. Stress induced right ventricular dysfunction: An indication of reversible right ventricular ischaemia

    International Nuclear Information System (INIS)

    Underwood, S.R.; Walton, S.; Emanuel, R.W.; Swanton, R.H.; Campos Costa, D.; Laming, P.J.; Ell, P.J.

    1987-01-01

    Stress induced changes in left ventricular ejection fraction are widely used in the detection and assessment of coronary artery disease. This study demonstrates that right ventricular dysfunction may also occur, and assesses its significance in terms of coronary artery anatomy. This study involved 14 normal subjects and 26 with coronary artery disease investigated by equilibrium radionuclide ventriculography, at rest and during maximal dynamic exercise. Mean normal resting right ventricular ejection fraction (RVEF) was 0.40 (SD 0.118), and all normal subjects increased RVEF with stress (mean ΔRVEF+0.13 SD 0.099). Mean ΔRVEF in the subjects with coronary artery disease was significantly lower at 0.00 (SD 0.080), but there was overlap between the two groups. The largest falls in RVEF were seen if the right coronary artery was occluded without retrograde filling. In this subgroup with the most severely compromised right ventricular perfusion (nine subjects), RVEF always fell with stress, and mean ΔRVEF was -0.08 (SD 0.050). There was no significant correlation between ΔLVEF and ΔRVEF, implying that the right ventricular dysfunction was due to right ventricular ischaemia, rather than secondary to left ventricular dysfunction. Stress induced right ventricular ischaemia can therefore be detected readily by radionuclide ventriculography. (orig.)

  5. β1-Adrenoceptor blocker aggravated ventricular arrhythmia.

    Science.gov (United States)

    Wang, Yan; Patel, Dimpi; Wang, Dao Wu; Yan, Jiang Tao; Hsia, Henry H; Liu, Hao; Zhao, Chun Xia; Zuo, Hou Juan; Wang, Dao Wen

    2013-11-01

    To assess the impact of β1 -adrenoceptor blockers (β1 -blocker) and isoprenaline on the incidence of idiopathic repetitive ventricular arrhythmia that apparently decreases with preprocedural anxiety. From January 2010 to July 2012, six patients were identified who had idiopathic ventricular arrhythmias that apparently decreased (by greater than 90%) with preprocedural anxiety. The number of ectopic ventricular beats per hour (VPH) was calculated from Holter or telemetry monitoring to assess the ectopic burden. The mean VPH of 24 hours from Holter before admission (VPH-m) was used as baseline (100%) for normalization. β1 -Blockers, isoprenaline, and/or aminophylline were administrated successively on the ward and catheter lab to evaluate their effects on the ventricular arrhythmias. Among 97 consecutive patients with idiopathic ventricular arrhythmias, six had reduction in normalized VPHs in the hour before the scheduled procedure time from (104.6 ± 4.6%) to (2.8 ± 1.6%) possibly due to preprocedural anxiety (P < 0.05), then increased to (97.9 ± 9.7%) during β1 -blocker administration (P < 0.05), then quickly reduced to (1.6 ± 1.0%) during subsequent isoprenaline infusion. Repeated β1 -blocker quickly counteracted the inhibitory effect of isoprenaline, and VPHs increased to (120.9 ± 2.4%) from (1.6 ± 1.0%; P < 0.05). Isoprenaline and β1 -blocker showed similar effects on the arrhythmias in catheter lab. In some patients with structurally normal heart and ventricular arrhythmias there is a marked reduction of arrhythmias associated with preprocedural anxiety. These patients exhibit a reproducible sequence of β1 -blocker aggravation and catecholamine inhibition of ventricular arrhythmias, including both repetitive ventricular premature beats and monomorphic ventricular tachycardia. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  6. Assessment of left ventricular function by gated cardiac blood-pool emission computed tomography using a rotating gamma camera

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa; Honda, Minoru

    1991-01-01

    To elucidate the usefulness of gated cardiac blood-pool single photon emission CT (SPECT) with Tc-99m for the evaluation of left ventricular (LV) global and regional functions, 18 patients with coronary artery disease were studied. Thirty-two gated projection images were obtained over 360-degree at 16 frames per cardiac cycle. As LV volume was calculated by integrating the numbers of voxels which constituted LV and multiplying by the volume of a single voxel (0.1143 ml), we performed phantom studies to determine the appropriate cut-off level to detect LV outline. These cut-off levels were affected by the background activity and organ volume itself. So we constructed Volume-Cut-Level-Curve at each background activity. In clinical studies, short axis images which constituted LV were selected and provisional LV volumes were calculated at the cut-off levels of 45, 50 and 55%. These volumes were plotted on the Volume-Cut-Level-Curve and the true cut-off levels were obtained to calculate LV end-diastolic or end-systolic volume (EDV, ESV). The cut-off levels were different at every patient and ED or ES. EDV, ESV and LV ejection fraction obtained by SPECT were correlatd well with those obtained by contrast ventriculography (LVG) (r=0.89, 0.94, 0.94 each, p<0.01). For the LV wall motion analysis, LVGs obtained at two projections were compared with SPECT or gated cardiac blood-pool planar imaging (Planar) in 5 segments. In addition to visual comparison, wall motion scores (WMS) based on the degree of wall motion abnormality were calculated in each segment. Correlation of WMS between LVG and SPECT (r=0.84) was significantly (p<0.01) superior to that between LVG and Planar (r=0.62). Especially in SPECT, wall motion analyses at septal and infero-posterior segments were superior to those in Planar. Although gated SPECT requires relatively long time to perform, it is a useful method to detect LV global and regional functions. (author)

  7. Assessment of congenital heart disease by a thallium-201 SPECT study in children; Accuracy of estimated right to left ventricular pressure ratio

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, Iwao; Nakajima, Kenichi; Taki, Junichi; Taniguchi, Mitsuru; Bunko, Hisashi; Tonami, Norihisa; Hisada, Kinichi; Ohno, Takashi (Kanazawa Univ. (Japan). School of Medicine)

    1993-01-01

    The characteristics of correlation between the right-to-left ventricular systolic pressure ratios (RVp/LVp) and the thallium-201 right-to-left ventricular ([sup 201]Tl R/L) count ratios was investigated in children with various congenital heart diseases. High-resolution three-headed SPECT system equipped with either parallel-hole or fan-beam collimators was used. In a total of 102 patients, the correlation between RVp/LVp and [sup 201]Tl R/L average count ratios was good in both planar (r=0.89, p=0.0001) and SPECT studies (r=0.80, p=0.0001). Quantitative analysis of myocardial uptake by SPECT demonstrated the characteristic pattern of each disease as well as the differences in the right ventricular overload types. When the linear regression analysis was performed in each heart disease, ventricular septal defect showed most excellent correlation. Complex heart anomalies also showed positive correlation (r=0.51, p=0.05) with RVp/LVp, and it can be used to estimate right ventricular pressure. After surgical treatment of tetralogy of Fallot and pulmonary stenosis, the decrease of [sup 201]Tl R/L count ratio was in accordance with improvement of right ventricular overload. We conclude that [sup 201]Tl SPECT study can be a good indicator for estimation of right ventricular pressure. (author).

  8. Utilizing Three-Dimensional Printing Technology to Assess the Feasibility of High-Fidelity Synthetic Ventricular Septal Defect Models for Simulation in Medical Education.

    Science.gov (United States)

    Costello, John P; Olivieri, Laura J; Krieger, Axel; Thabit, Omar; Marshall, M Blair; Yoo, Shi-Joon; Kim, Peter C; Jonas, Richard A; Nath, Dilip S

    2014-07-01

    The current educational approach for teaching congenital heart disease (CHD) anatomy to students involves instructional tools and techniques that have significant limitations. This study sought to assess the feasibility of utilizing present-day three-dimensional (3D) printing technology to create high-fidelity synthetic heart models with ventricular septal defect (VSD) lesions and applying these models to a novel, simulation-based educational curriculum for premedical and medical students. Archived, de-identified magnetic resonance images of five common VSD subtypes were obtained. These cardiac images were then segmented and built into 3D computer-aided design models using Mimics Innovation Suite software. An Objet500 Connex 3D printer was subsequently utilized to print a high-fidelity heart model for each VSD subtype. Next, a simulation-based educational curriculum using these heart models was developed and implemented in the instruction of 29 premedical and medical students. Assessment of this curriculum was undertaken with Likert-type questionnaires. High-fidelity VSD models were successfully created utilizing magnetic resonance imaging data and 3D printing. Following instruction with these high-fidelity models, all students reported significant improvement in knowledge acquisition (P 3D printing technology to create high-fidelity heart models with complex intracardiac defects. Furthermore, this tool forms the foundation for an innovative, simulation-based educational approach to teach students about CHD and creates a novel opportunity to stimulate their interest in this field. © The Author(s) 2014.

  9. Semi-quantitative assessment of right ventricular function in comparison to a 3D volumetric approach: A cardiovascular magnetic resonance study

    Energy Technology Data Exchange (ETDEWEB)

    Nijveldt, Robin; Germans, Tjeerd; Rossum, Albert C. van [VU University Medical Center, Department of Cardiology, Amsterdam (Netherlands); Interuniversity Cardiology Institute of the Netherlands, Utrecht (Netherlands); McCann, Gerald P. [University Hospitals Leicester, Department of Cardiology, Leicester (United Kingdom); Beek, Aernout M. [VU University Medical Center, Department of Cardiology, Amsterdam (Netherlands)

    2008-11-15

    Right ventricular (RV) volume measurements with cardiovascular magnetic resonance (CMR) is considered the gold standard, but acquisition and analysis remain time-consuming. The aim of our study was therefore to investigate the accuracy and performance of a semi-quantitative assessment of RV function in CMR, compared to the standard quantitative approach. Seventy-five subjects with pulmonary hypertension (15), anterior myocardial infarction (15), inferior myocardial infarction (15), Brugada syndrome (15) and normal subjects (15) underwent cine CMR. RV end-systolic and end-diastolic volumes were determined to calculate RV ejection fraction (EF). Four-chamber cine images were used to measure tricuspid annular plane systolic excursion (TAPSE). RV fractional shortening (RVFS) was calculated by dividing TAPSE by the RV end-diastolic length. RV EF correlated significantly with TAPSE (r = 0.62, p < 0.01) and RVFS (r = 0.67, p < 0.01). Sensitivity to predict RV dysfunction was comparable between TAPSE and RVFS, with higher specificity for RVFS, but comparable areas under the ROC curve. Intra- and inter-observer variability of RV EF was better than TAPSE (3%/4% versus 7%/15%, respectively). For routine screening in clinical practice, TAPSE and RVFS seem reliable and easy methods to identify patients with RV dysfunction. The 3D volumetric approach is preferred to assess RV function for research purposes or to evaluate treatment response. (orig.)

  10. Avaliação quantitativa da movimentação parietal regional do ventrículo esquerdo na endomiocardiofibrose Quantitative assessment of left ventricular regional wall motion in endomyocardial fibrosis

    Directory of Open Access Journals (Sweden)

    Charles Mady

    2005-03-01

    motion in patients with endomyocardial fibrosis (EMF. METHODS: The study comprised 88 patients, 59 of the female sex, with a mean age of 39±13 years (range, 9 to 65 and with echocardiographic and angiographic evidence of left ventricular EMF. The intensity of fibrous tissue buildup on contrast cineventriculography was classified as mild, moderate, or severe. The overall left ventricular ejection fraction (LVEF was determined by using the area-length method on ventriculography. The motion was measured in 100 equidistant chords perpendicular to the centerline drawn in the middle of the final diastolic and systolic contours and normalized to cardiac size. Five left ventricular segments were analyzed: A - apical; AL - anterolateral; AB - anterobasal; IA - inferoapical; IB - inferobasal. Abnormality was expressed in units of standard deviation of the mean motion in a normal population of reference, comprised of 103 patients with normal LV according to clinical and electrocardiographic data, and angiographic standards. RESULTS: Mean LVEF was 0.47±0.12. Fibrous tissue buildup in the left ventricle was mild in 12 patients, moderate in 40, and severe in 36. The regions with the poorest ventricular wall motion were A (-1.4±1.6 standard deviation/chords and IA (-1.6±1.8 standard deviation/chords compared with that in AB (-0.3±1.9 standard deviation/chords, AL (-0.5±1.8 standard deviation/chords and IB (-0.9±1.3 standard deviation/chords. No relation was observed between the intensity of fibrous tissue buildup and regional ventricular wall motion. CONCLUSION: A change in LV regional wall motion exists in EMF, and it is independent of the intensity of fibrous tissue buildup qualitatively assessed. Nonuniform involvement of the LV should be considered when planning surgery for this disease.

  11. CT provides precise size assessment of implanted titanium alloy pedicle screws.

    Science.gov (United States)

    Elliott, Michael J; Slakey, Joseph B

    2014-05-01

    After performing instrumented spinal fusion with pedicle screws, postoperative imaging using CT to assess screw position may be necessary. Stainless steel implants produce significant metal artifact on CT, and the degree of distortion is at least partially dependent on the cross-sectional area of the implanted device. If the same effect occurs with titanium alloy implants, ability to precisely measure proximity of screws to adjacent structures may be adversely affected as screw size increases. We therefore asked whether (1) CT provides precise measurements of true screw widths; and (2) precision degrades based on the size of the titanium implant imaged. CT scans performed on 20 patients after instrumented spinal fusion for scoliosis were reviewed. The sizes of 151 titanium alloy pedicle screws were measured and compared with known screw size. The amount of metal bloom artifact was determined for each of the four screw sizes. ANOVA with Tukey's post hoc test were performed to evaluate differences in scatter, and Spearman's rho coefficient was used to measure relationship between screw size and scatter. All screws measured larger than their known size, but even with larger 7-mm screws the size differential was less than 1 mm. The four different screw sizes produced scatter amounts that were different from each other (p titanium alloy pedicle screws produces minimal artifact, thus making this the preferred imaging modality to assess screw position after surgery. Although the amount of artifact increases with the volume of titanium present, the degree of distortion is minimal and is usually less than 1 mm.

  12. Comparison of left ventricular function assessment using phonocardiogram- and electrocardiogram-triggered 2D SSFP CINE MR imaging at 1.5 T and 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Meike [University Hospital, RWTH Aachen, Department of Diagnostic Radiology, Aachen (Germany); Humboldt-University, Experimental and Clinical Research Center (ECRC), Charite Campus Buch, Berlin (Germany); Frauenrath, Tobias; Hezel, Fabian [University Hospital, RWTH Aachen, Department of Diagnostic Radiology, Aachen (Germany); Berlin Ultrahigh Field Facility, Max-Delbrueck Center for Molecular Medicine, Berlin (Germany); Krombach, Gabriele A.; Kremer, Ute; Koppers, Benedikt [University Hospital, RWTH Aachen, Department of Diagnostic Radiology, Aachen (Germany); Butenweg, Christoph; Goemmel, Andreas [Chair of Structural Statics and Dynamics, RWTH Aachen, Aachen (Germany); Utting, Jane F. [MRI, NHS Grampian, Aberdeen Royal Infirmary, Aberdeen (United Kingdom); Schulz-Menger, Jeanette [Humboldt-University, Working Group Cardiovascular MR, Franz-Volhard-Klinik, Department of Cardiology, HELIOS-Klinikum Berlin-Buch and Charite Campus Buch, Berlin (Germany); Niendorf, Thoralf [University Hospital, RWTH Aachen, Department of Diagnostic Radiology, Aachen (Germany); Humboldt-University, Experimental and Clinical Research Center (ECRC), Charite Campus Buch, Berlin (Germany); Berlin Ultrahigh Field Facility, Max-Delbrueck Center for Molecular Medicine, Berlin (Germany)

    2010-06-15

    As high-field cardiac MRI (CMR) becomes more widespread the propensity of ECG to interference from electromagnetic fields (EMF) and to magneto-hydrodynamic (MHD) effects increases and with it the motivation for a CMR triggering alternative. This study explores the suitability of acoustic cardiac triggering (ACT) for left ventricular (LV) function assessment in healthy subjects (n = 14). Quantitative analysis of 2D CINE steady-state free precession (SSFP) images was conducted to compare ACT's performance with vector ECG (VCG). Endocardial border sharpness (EBS) was examined paralleled by quantitative LV function assessment. Unlike VCG, ACT provided signal traces free of interference from EMF or MHD effects. In the case of correct R-wave recognition, VCG-triggered 2D CINE SSFP was immune to cardiac motion effects - even at 3.0 T. However, VCG-triggered 2D SSFP CINE imaging was prone to cardiac motion and EBS degradation if R-wave misregistration occurred. ACT-triggered acquisitions yielded LV parameters (end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF) and left ventricular mass (LVM)) comparable with those derived from VCG-triggered acquisitions (1.5 T: ESV{sub VCG} = (56 {+-} 17) ml, EDV{sub VCG} = (151 {+-} 32) ml, LVM{sub VCG} = (97 {+-} 27) g, SV{sub VCG} = (94 {+-} 19) ml, EF{sub VCG} = (63 {+-} 5)% cf. ESV{sub ACT} = (56 {+-} 18) ml, EDV{sub ACT} = (147 {+-} 36) ml, LVM{sub ACT} = (102 {+-} 29) g, SV{sub ACT} = (91 {+-} 22) ml, EF{sub ACT} = (62 {+-} 6)%; 3.0 T: ESV{sub VCG} = (55 {+-} 21) ml, EDV{sub VCG} = (151 {+-} 32) ml, LVM{sub VCG} = (101 {+-} 27) g, SV{sub VCG} = (96 {+-} 15) ml, EF{sub VCG} = (65 {+-} 7)% cf. ESV{sub ACT} = (54 {+-} 20) ml, EDV{sub ACT} = (146 {+-} 35) ml, LVM{sub ACT} = (101 {+-} 30) g, SV{sub ACT} = (92 {+-} 17) ml, EF{sub ACT} = (64 {+-} 6)%). ACT's intrinsic insensitivity to interference from electromagnetic fields renders it suitable for clinical CMR. (orig.)

  13. Diagnostic accuracy of cardiovascular magnetic resonance imaging for assessment of right ventricular morphology and function in pulmonary artery hypertension

    Directory of Open Access Journals (Sweden)

    Eman Ramzy Ali

    2017-07-01

    Conclusions: CMR imaging is likely to increase in importance as the optimal reference method for assessment of early structural (morphological and functional parameters of the right ventricle for evaluation of patients with suspected PH valuable for assessment of treatment response, follow up and prognosis.

  14. Left ventricular function assessment using a fast 3D gradient echo pulse sequence: comparison to standard multi-breath hold 2D steady state free precession imaging and accounting for papillary muscles and trabeculations.

    Science.gov (United States)

    Sievers, Burkhard; Schrader, Sebastian; Rehwald, Wolfgang; Hunold, Peter; Barkhausen, Joerg; Erbel, Raimund

    2011-06-01

    Papillary muscles and trabeculae for ventricular function analysis are known to significantly contribute to accurate volume and mass measurements. Fast imaging techniques such as three-dimensional steady-state free precession (3D SSFP) are increasingly being used to speed up imaging time, but sacrifice spatial resolution. It is unknown whether 3D SSFP, despite its reduced spatial resolution, allows for exact delineation of papillary muscles and trabeculations. We therefore compared 3D SSFP ventricular function measurements to those measured from standard multi-breath hold two-dimensional steady-state free precession cine images (standard 2D SSFP). 14 healthy subjects and 14 patients with impaired left ventricularfunction underwent 1.5 Tesla cine imaging. A stack of short axis images covering the left ventricle was acquired with 2D SSFP and 3D SSFP. Left ventricular volumes, ejection fraction, and mass were determined. Analysis was performed by substracting papillary muscles and trabeculae from left ventricular volumes. In addition, reproducibility was assessed. EDV, ESV, EF, and mass were not significantly different between 2D SSFP and 3D SSFP (mean difference healthy subjects: -0.06 +/- 3.2 ml, 0.54 +/- 2.2 ml, -0.45 +/- 1.8%, and 1.13 +/- 0.8 g, respectively; patients: 1.36 +/- 2.8 ml, -0.15 3.5 ml, 0.86 +/- 2.5%, and 0.91 +/- 0.9 g, respectively; P > or = 0.095). Intra- and interobserver variability was not different for 2D SSFP (P > or = 0.64 and P > or = 0.397) and 3D SSFP (P > or = 0.53 and P > or = 0.47). Differences in volumes, EF, and mass measurements between 3D SSFP and standard 2D SSFP are very small, and not statistically significant. 3D SSFP may be used for accurate ventricular function assessment when papillary muscles and trabeculations are to be taken into account.

  15. Reduced variability of visual left ventricular ejection fraction assessment with reference images: The Japanese Association of Young Echocardiography Fellows multicenter study.

    Science.gov (United States)

    Kusunose, Kenya; Shibayama, Kentaro; Iwano, Hiroyuki; Izumo, Masaki; Kagiyama, Nobuyuki; Kurosawa, Koji; Mihara, Hirotsugu; Oe, Hiroki; Onishi, Tetsuari; Onishi, Toshinari; Ota, Mitsuhiko; Sasaki, Shunsuke; Shiina, Yumi; Tsuruta, Hikaru; Tanaka, Hidekazu

    2018-07-01

    Visual estimation of left ventricular ejection fraction (LVEF) is widely applied to confirm quantitative EF. However, visual assessment is subjective, and variability may be influenced by observer experience. We hypothesized that a learning session might reduce the misclassification rate. Protocol 1: Visual LVEFs for 30 cases were measured by 79 readers from 13 cardiovascular tertiary care centers. Readers were divided into 3 groups by their experience: limited (1-5 years, n=28), intermediate (6-11 years, n=26), and highly experienced (12-years, n=25). Protocol 2: All readers were randomized to assess the effect of a learning session with reference images only or feedback plus reference images. After the session, 20 new cases were shown to all readers following the same methodology. To assess the concordance and accuracy pre- and post-intervention, each visual LVEF measurement was compared to overall average values as a reference. Experience affected the concordance in visual EF values among the readers. Groups with intermediate and high experience showed significantly better mean difference (MD), standard deviation (SD), and coefficient of variation (CV) than those with limited experience at baseline. The learning session with reference image reduced the MD, SD, and CV in readers with limited experience. The learning session with reference images plus feedback also reduced proportional bias. Importantly, the misclassification rate for mid-range EF cases was reduced regardless of experience. This large multicenter study suggested that a simple learning session with reference images can successfully reduce the misclassification rate for LVEF assessment. Copyright © 2018 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  16. Effects of chronic severe pulmonary regurgitation and percutaneous valve repair on right ventricular geometry and contractility assessed by tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Kjaergaard, Jesper; Iversen, Kasper K; Vejlstrup, Niels G

    2010-01-01

    Pulmonary regurgitation (PR) following repair of right ventricular (RV) outflow obstruction is related to slowly progressive RV dilatation and heart failure and will eventually require surgical intervention, but optimal timing of pulmonary valve replacement is challenging. Tissue Doppler based...

  17. Assessment of left ventricular myocardial function using 16-slice multidetector-row computed tomography: comparison with magnetic resonance imaging and echocardiography

    International Nuclear Information System (INIS)

    Heuschmid, Martin; Rothfuss, Julia K.; Fenchel, Michael; Stauder, Norbert; Kuettner, Axel; Miller, Stephan; Claussen, Claus D.; Kopp, Andreas F.; Schroeder, Stephen; Burgstahler, Christof; Franow, Andreas; Kuzo, Ronald S.

    2006-01-01

    To assess functional parameters using multidetector-row computed tomography (MDCT) and echocardiography and to compare the results with magnetic resonance imaging (MRI). End-diastolic-volume (EDV), end-systolic-volume (ESV), stroke-volume (SV), ejection-fraction (EF), and myocardial mass (MM) were calculated based on CT data sets from 52 patients. Echocardiography was performed in 24 of the 52 patients. The results from MDCT and echocardiography were compared with MRI. A strong correlation between MDCT and MRI (r=0.66-0.90) was found for all parameters. Echocardiography revealed a low or moderate correlation (0.05-0.59). Compared to MRI the average differences with MDCT were for EDV 15.1 ml, ESV 10.6 ml, SV 4.5 ml, EF 1.8%, and MM 8.2 g, for EDV determined by echocardiography 36.2 ml, ESV 6.8 ml, and EF 13.9%. Bland-Altman analysis revealed acceptable limits of agreement between MRI and MDCT. MDCT enables reliable quantification of left ventricular function. Echocardiography was found to have only a moderate agreement of functional parameters with MRI. (orig.)

  18. [Assessment of the right ventricular function in healthy volunteers with one beat full-volume real-time three-dimensional echocardiography].

    Science.gov (United States)

    Zhu, Wei-hong; Zhang, Jin; Tong, Kai; Zhi, Guang; He, Kun-lun

    2012-08-01

    To determine the normal value of right ventricle using one beat full-volume real-time three-dimensional echocardiography (RT-3DE) and assess the feasibility of this technique. One beat full volume images were acquired at the apical 4 chamber view in 129 healthy volunteers. The right and left ventricular volumes were examined with the eSie LVA and RVA. The subjects were divided into 2 gender groups (male and female) and 3 age groups (20 - 39 years old, 40 - 59 years old, 60 years old and above). Adequate data were obtained in 129 subjects. The RV-EDV was (92.4 ± 21.3) ml, RV-ESV (34.6 ± 9.2) ml, RV-SV (57.8 ± 13.9) ml, RV-EF (62.5 ± 5.0) ml. EDV, ESV, and EF were significant different while SV was similar between RV and LV (all P Right ventricle function can be measured noninvasively by RT-3DE with high feasibility. This novel method contributes to the detailed study of right heart function in various cardiovascular diseases.

  19. Cardiac MRI: evaluation of phonocardiogram-gated cine imaging for the assessment of global und regional left ventricular function in clinical routine

    International Nuclear Information System (INIS)

    Nassenstein, Kai; Schlosser, Thomas; Orzada, Stephan; Haering, Lars; Czylwik, Andreas; Zenge, Michael; Mueller, Edgar; Eberle, Holger; Bruder, Oliver; Ladd, Mark E.; Maderwald, Stefan

    2012-01-01

    To validate a phonocardiogram (PCG)-gated cine imaging approach for the assessment of left ventricular (LV) function. In this prospective study, cine MR imaging of the LV was performed twice in 79 patients by using retrospectively PCG- and retrospectively ECG-gated cine SSFP sequences at 1.5 T. End-diastolic volumes (EDV), end-systolic volumes (ESV), stroke volumes (SV), ejection fraction (EF), muscle mass (MM), as well as regional wall motion were assessed. Subgroup analyses were performed for patients with valvular defects and for patients with dysrhythmia. PCG-gated imaging was feasible in 75 (95%) patients, ECG-gating in all patients. Excellent correlations were observed for all volumetric parameters (r > 0.98 for all variables analysed). No significant differences were observed for EDV (-0.24 ± 3.14 mL, P = 0.5133), ESV (-0.04 ± 2.36 mL, P = 0.8951), SV (-0.20 ± 3.41 mL, P = 0.6083), EF (-0.16 ± 1.98%, P = 0.4910), or MM (0.31 ± 4.2 g, P = 0.7067) for the entire study cohort, nor for either of the subgroups. PCG- and ECG-gated cine imaging revealed similar results for regional wall motion analyses (115 vs. 119 segments with wall motion abnormalities, P = 0.3652). The present study demonstrates that PCG-gated cine imaging enables accurate assessment of global and regional LV function in the vast majority of patients in clinical routine. (orig.)

  20. Antarctic krill; assessment of mesh size selectivity and escape mortality from trawls

    DEFF Research Database (Denmark)

    Krafft, Bjørn A.; Krag, Ludvig Ahm; Herrmann, Bent

    2015-01-01

    Marine AS. The project will examine krill escape mortality from the codend during a full scale field experiment, model size selectivity and escape mortality in codends including different designs and assess the size selectivity in the trawl body forward of the codend. Based on end results from the preceding...... examinations we will be able to predict size selectivity and escape mortality from the entire trawl body with the appurtenant mortality for different trawl designs......This working paper presents the aims and methodology for a three-year-project (commenced in 2015) assessing size selectivity and escape mortality of Antarctic krill from trawl nets. The project is widely based on acquired experiences from a completed study Net Escapement of Antarctic krill...

  1. Assessment of left ventricular volumes by magnetic resonance in comparison with radionuclide angiography, contrast angiography and echocardiography

    DEFF Research Database (Denmark)

    Møgelvang, J; Stokholm, K H; Saunamäki, K

    1992-01-01

    The present study shows that for assessment of LVEF, MRI and the standard methods seem to provide information of similar value. For absolute volume measurements, MRI and RNA are superior to single plane angiography and 2 DE using the modified Simpson-rule. The time consuming transversal MRI method...... quality, which is crucial especially in dilated ventricles containing stagnant or slowly moving blood....

  2. Undersampling power-law size distributions: effect on the assessment of extreme natural hazards

    Science.gov (United States)

    Geist, Eric L.; Parsons, Thomas E.

    2014-01-01

    The effect of undersampling on estimating the size of extreme natural hazards from historical data is examined. Tests using synthetic catalogs indicate that the tail of an empirical size distribution sampled from a pure Pareto probability distribution can range from having one-to-several unusually large events to appearing depleted, relative to the parent distribution. Both of these effects are artifacts caused by limited catalog length. It is more difficult to diagnose the artificially depleted empirical distributions, since one expects that a pure Pareto distribution is physically limited in some way. Using maximum likelihood methods and the method of moments, we estimate the power-law exponent and the corner size parameter of tapered Pareto distributions for several natural hazard examples: tsunamis, floods, and earthquakes. Each of these examples has varying catalog lengths and measurement thresholds, relative to the largest event sizes. In many cases where there are only several orders of magnitude between the measurement threshold and the largest events, joint two-parameter estimation techniques are necessary to account for estimation dependence between the power-law scaling exponent and the corner size parameter. Results indicate that whereas the corner size parameter of a tapered Pareto distribution can be estimated, its upper confidence bound cannot be determined and the estimate itself is often unstable with time. Correspondingly, one cannot statistically reject a pure Pareto null hypothesis using natural hazard catalog data. Although physical limits to the hazard source size and by attenuation mechanisms from source to site constrain the maximum hazard size, historical data alone often cannot reliably determine the corner size parameter. Probabilistic assessments incorporating theoretical constraints on source size and propagation effects are preferred over deterministic assessments of extreme natural hazards based on historic data.

  3. Non-invasive assessment of the effects of drugs on acute myocardial infarct size in man

    Energy Technology Data Exchange (ETDEWEB)

    Maclean, D [Ninewells Hospital and Medical School, Dundee (UK)

    1979-06-01

    The amount of necrotic myocardium following acute coronary artery occlusion influences both the early and long-term consequences of myocardial infarction. Experiments, however, indicate that several drugs given early after the occlusion can substantially alter final infarct size. Clinical assessment of the effects of these drugs poses difficulties and an awareness of the limitations of existing methods is essential for their successful application. This discussion is restricted largely to the advantages and disadvantages of the three main methods currently used for assessing acute myocardial infarct size:-praecordial electrocardiographic mapping, serial estimates of serum creatine kinase activity, and radionuclide scintigraphy.

  4. Echocardiographic Assessment of Left Ventricular Function in Healthy Horses and in Horses with Heart Disease Using Pulsed-Wave Tissue Doppler Imaging.

    Science.gov (United States)

    Koenig, T R; Mitchell, K J; Schwarzwald, C C

    2017-03-01

    Assessment of left ventricular (LV) function by tissue Doppler imaging (TDI) is not well established in horses with heart disease. To describe the use of pulsed-wave (PW) TDI for the assessment of LV function, establish reference intervals, investigate effects of mitral regurgitation (MR), aortic regurgitation (AR), and primary myocardial disease (MD), and provide proof of concept for the use of PW TDI in Warmblood horses with heart disease. Thirty healthy horses, 38 horses with MR, 25 with AR, 8 with MD. Echocardiograms were retrospectively analyzed. Reference intervals were calculated. PW TDI indices of healthy horses and horses with MR, AR, and MD were compared by one-way ANOVA and Dunnett's test. A complete set of PW TDI variables could be obtained in 94 of 101 horses. Variables corresponding to isovolumic intervals were most difficult to measure. Valvular regurgitation influenced variables describing isovolumic contraction and ejection. Horses with MD had significantly shortened ET m (-118.5 [-154.1 to -82.9] ms; mean difference [95% CI of difference of means]), increased PEP m /ET m (0.11 [0.05 to 0.17]), prolonged IMP m (0.28 [0.18 to 0.37]), increased S 1 (8.9 [5.2 to 12.6] cm/s), and decreased E 1 (-2.6 [-4.7 to -0.5] cm/s), E m (-14.2 [-19.9 to -8.5] cm/s), and E m /A m ratio (-1.6 [-2.6 to -0.6]). Pulsed-wave TDI might be useful for detection of LV dysfunction in horses with primary MD. The clinical value of TDI in horses with MR and AR remains uncertain. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  5. Ventricular Septal Defect (VSD)

    Science.gov (United States)

    ... Call your doctor if your baby or child: Tires easily when eating or playing Is not gaining ... heart procedures. Risk factors Ventricular septal defects may run in families and sometimes may occur with other ...

  6. The influence of type 2 diabetes and gender on ventricular repolarization dispersion in patients with sub-clinic left ventricular diastolic dysfunction

    OpenAIRE

    Jani, Ylber; Kamberi, Ahmet; Xhunga, Sotir; Pocesta, Bekim; Ferati, Fatmir; Lala, Dali; Zeqiri, Agim; Rexhepi, Atila

    2015-01-01

    Objective: To assess the influence of type 2 DM and gender, on the QT dispersion, Tpeak-Tend dispersion of ventricular repolarization, in patients with sub-clinic left ventricular diastolic dysfunction of the heart. Background: QT dispersion, that reflects spatial inhomogeneity in ventricular repolarization, Tpeak-Tend dispersion, this on the other hand reflects transmural inhomogeneity in ventricular repolarization, that is increased in an early stage of cardiomyopathy, and in patients with ...

  7. Exercise thallium testing in ventricular preexcitation

    Energy Technology Data Exchange (ETDEWEB)

    Archer, S.; Gornick, C.; Grund, F.; Shafer, R.; Weir, E.K.

    1987-05-01

    Ventricular preexcitation, as seen in Wolff-Parkinson-White syndrome, results in a high frequency of positive exercise electrocardiographic responses. Why this occurs is unknown but is not believed to reflect myocardial ischemia. Exercise thallium testing is often used for noninvasive assessment of coronary artery disease in patients with conditions known to result in false-positive electrocardiographic responses. To assess the effects of ventricular preexcitation on exercise thallium testing, 8 men (aged 42 +/- 4 years) with this finding were studied. No subject had signs or symptoms of coronary artery disease. Subjects exercised on a bicycle ergometer to a double product of 26,000 +/- 2,000 (+/- standard error of mean). All but one of the subjects had at least 1 mm of ST-segment depression. Tests were terminated because of fatigue or dyspnea and no patient had chest pain. Thallium test results were abnormal in 5 patients, 2 of whom had stress defects as well as abnormally delayed thallium washout. One of these subjects had normal coronary arteries on angiography with a negative ergonovine challenge, and both had normal exercise radionuclide ventriculographic studies. Delayed thallium washout was noted in 3 of the subjects with ventricular preexcitation and normal stress images. This study suggests that exercise thallium testing is frequently abnormal in subjects with ventricular preexcitation. Ventricular preexcitation may cause dyssynergy of ventricular activation, which could alter myocardial thallium handling, much as occurs with left bundle branch block. Exercise radionuclide ventriculography may be a better test for noninvasive assessment of coronary artery disease in patients with ventricular preexcitation.

  8. Exercise thallium testing in ventricular preexcitation

    International Nuclear Information System (INIS)

    Archer, S.; Gornick, C.; Grund, F.; Shafer, R.; Weir, E.K.

    1987-01-01

    Ventricular preexcitation, as seen in Wolff-Parkinson-White syndrome, results in a high frequency of positive exercise electrocardiographic responses. Why this occurs is unknown but is not believed to reflect myocardial ischemia. Exercise thallium testing is often used for noninvasive assessment of coronary artery disease in patients with conditions known to result in false-positive electrocardiographic responses. To assess the effects of ventricular preexcitation on exercise thallium testing, 8 men (aged 42 +/- 4 years) with this finding were studied. No subject had signs or symptoms of coronary artery disease. Subjects exercised on a bicycle ergometer to a double product of 26,000 +/- 2,000 (+/- standard error of mean). All but one of the subjects had at least 1 mm of ST-segment depression. Tests were terminated because of fatigue or dyspnea and no patient had chest pain. Thallium test results were abnormal in 5 patients, 2 of whom had stress defects as well as abnormally delayed thallium washout. One of these subjects had normal coronary arteries on angiography with a negative ergonovine challenge, and both had normal exercise radionuclide ventriculographic studies. Delayed thallium washout was noted in 3 of the subjects with ventricular preexcitation and normal stress images. This study suggests that exercise thallium testing is frequently abnormal in subjects with ventricular preexcitation. Ventricular preexcitation may cause dyssynergy of ventricular activation, which could alter myocardial thallium handling, much as occurs with left bundle branch block. Exercise radionuclide ventriculography may be a better test for noninvasive assessment of coronary artery disease in patients with ventricular preexcitation

  9. Laser cutting of various materials: Kerf width size analysis and life cycle assessment of cutting process

    Science.gov (United States)

    Yilbas, Bekir Sami; Shaukat, Mian Mobeen; Ashraf, Farhan

    2017-08-01

    Laser cutting of various materials including Ti-6Al-4V alloy, steel 304, Inconel 625, and alumina is carried out to assess the kerf width size variation along the cut section. The life cycle assessment is carried out to determine the environmental impact of the laser cutting in terms of the material waste during the cutting process. The kerf width size is formulated and predicted using the lump parameter analysis and it is measured from the experiments. The influence of laser output power and laser cutting speed on the kerf width size variation is analyzed using the analytical tools including scanning electron and optical microscopes. In the experiments, high pressure nitrogen assisting gas is used to prevent oxidation reactions in the cutting section. It is found that the kerf width size predicted from the lump parameter analysis agrees well with the experimental data. The kerf width size variation increases with increasing laser output power. However, this behavior reverses with increasing laser cutting speed. The life cycle assessment reveals that material selection for laser cutting is critical for the environmental protection point of view. Inconel 625 contributes the most to the environmental damages; however, recycling of the waste of the laser cutting reduces this contribution.

  10. Influence of Sample Size on Automatic Positional Accuracy Assessment Methods for Urban Areas

    Directory of Open Access Journals (Sweden)

    Francisco J. Ariza-López

    2018-05-01

    Full Text Available In recent years, new approaches aimed to increase the automation level of positional accuracy assessment processes for spatial data have been developed. However, in such cases, an aspect as significant as sample size has not yet been addressed. In this paper, we study the influence of sample size when estimating the planimetric positional accuracy of urban databases by means of an automatic assessment using polygon-based methodology. Our study is based on a simulation process, which extracts pairs of homologous polygons from the assessed and reference data sources and applies two buffer-based methods. The parameter used for determining the different sizes (which range from 5 km up to 100 km has been the length of the polygons’ perimeter, and for each sample size 1000 simulations were run. After completing the simulation process, the comparisons between the estimated distribution functions for each sample and population distribution function were carried out by means of the Kolmogorov–Smirnov test. Results show a significant reduction in the variability of estimations when sample size increased from 5 km to 100 km.

  11. Assessment of the right ventricular function in patients with chronic obstructive pulmonary disease and cor pulmonale using cardiac 64-slice spiral CT comparing with 1.7 T MRI

    International Nuclear Information System (INIS)

    Gao Yan; Li Kuncheng; Du Xiangying; Liang Lei; Cao Lizhen; Li Yan; Zhao Shen; Guo Ying

    2009-01-01

    Objective: To assess the right ventricular function in patients with moderate to severe chronic obstructive pulmonary disease (COPD) and eor pulmonale using cardiac 64 MSCT comparing with MRI. Methods: Forty-six patients with COPD determined by pulmonary function test (PFT) were prospectively studied. According to the Global Initiative for COPD classification, the COPD patients were divided into three groups depending on the severity of the disease: mild COPD (16 cases), moderate COPD (16 cases) and severe COPD (14 cases). Twenty age-matched subjects were included as the controls. The RV function was assessed by 64-MSCT and 1.5 T cardiac MRI in all four groups. Pearson correlation analysis was used to evaluate the relationship between the right ventricular ejection fraction (RVEF), myocardial mass (MM) and the PFT results in COPD patients. AP value of less than 0.05 was considered statistically significant. End-diastolic volume (EDV), end-systolic volume (ESV), RVEF and MM on MSCT were compared with that on MRI using Pearson correlation analysis. Bland-Airman plot was used to evaluate the correlation between MSCT and MRI. Results: The RVEF was (51.6 ± 5.6)% in mild COPD, (49.8 ± 6.0)% in moderate COPD, (39.4 ± 7.2)% in severe COPD, and (53 ± 5.9)% in controls, respectively. The MM was (44.5 ± 5.4) g in mild COPD, (49.6 ± 5.0) g in moderate COPD, (57.1 ± 3.4) g in severe COPD, and (40.8 ± 3.9) g in controls, respectively. The EDV was (139.9 ± 25.0), (130.2 ± 21.2), (107.6 ± 18.4) and (149.2 ± 27.9) ml, the SV was (72.1 ± 16.1), (64.3 ± 11.0), (42.5 ± 16.5) and (77.0 ± 11.7) ml in four groups, respectively. The values of RVEF and RVEDV were significantly lower in severe COPD than that in mild COPD, moderate COPD and controls (F RVEF =143, F RVEDV =38.07, P RVEF = 1.03, F EDV =3.22, F EFV =0.44, F SV =2.77, P>0.05). The MM of the RV was significantly different between controls and the other three groups (F=66.34, P<0.01). All parameters of the RV

  12. Sample Size Requirements for Assessing Statistical Moments of Simulated Crop Yield Distributions

    NARCIS (Netherlands)

    Lehmann, N.; Finger, R.; Klein, T.; Calanca, P.

    2013-01-01

    Mechanistic crop growth models are becoming increasingly important in agricultural research and are extensively used in climate change impact assessments. In such studies, statistics of crop yields are usually evaluated without the explicit consideration of sample size requirements. The purpose of

  13. Class Size Reduction or Rapid Formative Assessment?: A Comparison of Cost-Effectiveness

    Science.gov (United States)

    Yeh, Stuart S.

    2009-01-01

    The cost-effectiveness of class size reduction (CSR) was compared with the cost-effectiveness of rapid formative assessment, a promising alternative for raising student achievement. Drawing upon existing meta-analyses of the effects of student-teacher ratio, evaluations of CSR in Tennessee, California, and Wisconsin, and RAND cost estimates, CSR…

  14. Is there a correlation between operative results and change in ventricular volume after shunt placement? A study of 60 cases of idiopathic normal-pressure hydrocephalus

    Energy Technology Data Exchange (ETDEWEB)

    Meier, U.; Graewe, A.; Hajdukova, A. [Department of Neurosurgery, Unfallkrankenhaus Berlin, Warener Strasse 7, 12683, Berlin (Germany); Paris, S.; Stockheim, D.; Mutze, S. [Department of Radiology, Unfallkrankenhaus Berlin, Warener Strasse 7, 12683, Berlin (Germany)

    2003-06-01

    In patients with communicating or normal-pressure hydrocephalus, ventricular volume decreases following implantation of differential pressure valves. We implanted hydrostatic (Miethke dual-switch) valves in 60 patients with normal-pressure hydrocephalus (NPH) between September 1997 and December 2001. The patients underwent CT 1 year after operation, and we measured the Evans index. Although 83% of the patients showed no change in ventricular volume as assessed by this index, 72% nevertheless showed good to excellent and 16% satisfactory clinical improvement, while 12% showed no improvement. Moderate or marked reduction in ventricular size was observed in 17%, of whom 40% of these patients showed good to excellent and 20% satisfactory clinical improvement; 40% showed unsatisfactory improvement. The favourable outcome following implantation of a hydrostatic shunt thus did not correlate with decreased ventricular volume 1 year after operation, better outcomes being observed in patients with little or no alteration in ventricular size than in those with a marked decrease. Postoperative change in ventricular volume in NPH thus does not have the same significance as in patients with high-pressure hydrocephalus. (orig.)

  15. Is there a correlation between operative results and change in ventricular volume after shunt placement? A study of 60 cases of idiopathic normal-pressure hydrocephalus

    International Nuclear Information System (INIS)

    Meier, U.; Graewe, A.; Hajdukova, A.; Paris, S.; Stockheim, D.; Mutze, S.

    2003-01-01

    In patients with communicating or normal-pressure hydrocephalus, ventricular volume decreases following implantation of differential pressure valves. We implanted hydrostatic (Miethke dual-switch) valves in 60 patients with normal-pressure hydrocephalus (NPH) between September 1997 and December 2001. The patients underwent CT 1 year after operation, and we measured the Evans index. Although 83% of the patients showed no change in ventricular volume as assessed by this index, 72% nevertheless showed good to excellent and 16% satisfactory clinical improvement, while 12% showed no improvement. Moderate or marked reduction in ventricular size was observed in 17%, of whom 40% of these patients showed good to excellent and 20% satisfactory clinical improvement; 40% showed unsatisfactory improvement. The favourable outcome following implantation of a hydrostatic shunt thus did not correlate with decreased ventricular volume 1 year after operation, better outcomes being observed in patients with little or no alteration in ventricular size than in those with a marked decrease. Postoperative change in ventricular volume in NPH thus does not have the same significance as in patients with high-pressure hydrocephalus. (orig.)

  16. Assessment of ventriculo-vascular properties in repaired coarctation using cardiac magnetic resonance-derived aortic, left atrial and left ventricular strain

    Energy Technology Data Exchange (ETDEWEB)

    Shang, Quanliang [University of Nebraska College of Medicine and Children' s Hospital and Medical Center, Division of Pediatric Cardiology, Omaha, NE (United States); Central South University, Department of Radiology, Second Xiangya Hospital, Changsha, Hunan Province (China); Sarikouch, Samir; Beerbaum, Philipp [Hannover Medical School, Hannover (Germany); Patel, Shivani; Danford, David A.; Kutty, Shelby [University of Nebraska College of Medicine and Children' s Hospital and Medical Center, Division of Pediatric Cardiology, Omaha, NE (United States); Schuster, Andreas [Department of Cardiology and Pneumonology, Georg-August-University and German Center for Cardiovascular Research (DZHK, Partner Site), Goettingen (Germany); Steinmetz, Michael [Department of Pediatric Cardiology, Georg-August-University and German Center for Cardiovascular Research (DZHK, Partner Site), Goettingen (Germany); Ou, Phalla [University Paris Diderot, Department of Radiology, Hospital Bichat, APHP, Paris (France)

    2017-01-15

    In patients with repaired coarctation of aorta (CoA), we assessed ventriculo-vascular characteristics using CMR-derived aortic area strain (AAS), left atrial (LA) and left ventricular (LV) longitudinal and circumferential strain (LS, CS). Seventy-five subjects including 50 with repaired CoA divided into hypertensive (n = 25), normotensive (n = 25) and 25 controls were studied. AAS was measured at 3 levels: ascending aorta, proximal descending and descending aorta. LA and LV LS were measured using CMR-feature tracking. LA and LV end-diastolic volumes, ejection fraction (EF) and mass were measured. Mean patient age was 19.7 ± 6.7 and controls 23 ± 15 (years). All strains (LA, LV, ascending and descending aortic) were lower in CoA subgroups compared to controls except the AAS at diaphragm, which was not different. Comparisons between hypertensive and normotensive CoA showed no differences in LV mass, LV volumetric indices, and LA and LV strain indices; however, ascending AAS was lower in hypertensive subgroup (p = 0.02). Ascending AAS was correlated with LV mass (r = -0.4, p = 0.005), LVEF (r = -0.4, p = 0.004), systolic blood pressure (r = -0.5, p = 0.0001) and LVLS (r = 0.5, p = 0.001). Ascending AAS correlated with LV mass, EF and LVLS. In hypertensive CoA, ascending AAS was reduced compared to normotensive CoA and controls, indicating vascular remodelling differences influenced by ongoing hypertension. (orig.)

  17. Systolic ventricular filling.

    Science.gov (United States)

    Torrent-Guasp, Francisco; Kocica, Mladen J; Corno, Antonio; Komeda, Masashi; Cox, James; Flotats, A; Ballester-Rodes, Manel; Carreras-Costa, Francesc

    2004-03-01

    The evidence of the ventricular myocardial band (VMB) has revealed unavoidable coherence and mutual coupling of form and function in the ventricular myocardium, making it possible to understand the principles governing electrical, mechanical and energetical events within the human heart. From the earliest Erasistratus' observations, principal mechanisms responsible for the ventricular filling have still remained obscured. Contemporary experimental and clinical investigations unequivocally support the attitude that only powerful suction force, developed by the normal ventricles, would be able to produce an efficient filling of the ventricular cavities. The true origin and the precise time frame for generating such force are still controversial. Elastic recoil and muscular contraction were the most commonly mentioned, but yet, still not clearly explained mechanisms involved in the ventricular suction. Classical concepts about timing of successive mechanical events during the cardiac cycle, also do not offer understandable insight into the mechanism of the ventricular filling. The net result is the current state of insufficient knowledge of systolic and particularly diastolic function of normal and diseased heart. Here we summarize experimental evidence and theoretical backgrounds, which could be useful in understanding the phenomenon of the ventricular filling. Anatomy of the VMB, and recent proofs for its segmental electrical and mechanical activation, undoubtedly indicates that ventricular filling is the consequence of an active muscular contraction. Contraction of the ascendent segment of the VMB, with simultaneous shortening and rectifying of its fibers, produces the paradoxical increase of the ventricular volume and lengthening of its long axis. Specific spatial arrangement of the ascendent segment fibers, their interaction with adjacent descendent segment fibers, elastic elements and intra-cavitary blood volume (hemoskeleton), explain the physical principles

  18. Left ventricular function in right ventricular overload

    International Nuclear Information System (INIS)

    Iwanaga, Shiro; Handa, Shunnosuke; Abe, Sumihisa; Onishi, Shohei; Nakamura, Yoshiro; Kunieda, Etsuo; Ogawa, Koichi; Kubo, Atsushi

    1989-01-01

    This study clarified regional and global functions of the distorted left ventricle due to right ventricular overload by gated radionuclide ventriculography (RNV). Cardiac catheterization and RNV were performed in 13 cases of atrial septal defect (ASD), 13 of pure mitral stenosis (MS), 10 of primary pulmonary hypertension (PPH), and 10 of normal subjects (NL). Right ventricular systolic pressure (RVSP) was 32.9±13.9, 45.0±12.2, 88.3±17.1, and 21.2±4.5 mmHg, respectively. The end-systolic LAO view of the left ventricle was halved into septal and free-wall sides. The end-diastolic halves were determined in the same plane. Ejection fractions of the global left ventricle (LVEF), global right ventricle (RVEF), the septal half of the left ventricle (SEPEF), and the free-wall half of the left ventricle (FWEF) were obtained. LVEF was 56.8±9.8% in NL, 52.8±10.5% in ASD, and 49.5±12.9% in PPH. In MS, LVEF (47.0±13.0%) was smaller than those in the other groups. RVEF was 37.0±5.2% in NL, 43.7±15.5% in ASD, and 32.8±11.5% in MS. In PPH, RVEF (25.0±10.6%) was smaller than those in the other groups. SEPEF was smaller in ASD (42.5±13.2%), MS (40.4±13.1%), PPH (40.5±12.5%) than in NL (53.5±8.5%). Systolic function of the septal half of the left ventricle was disturbed by right ventricular overload. RVEF (r=-0.35, p<0.05) and SEPEF (r=-0.51, p<0.01) had negative correlations with RVSP. As RVSP rose, systolic function of the septal half of the left ventricle was more severely disturbed. FWEF was the same among the four groups; NL (57.0±12.6%), ASD (48.6±15.2%), MS (50.5±12.0%), and PPH (51.1±12.3%). There was a good correlation between SEPEF and LVEF in NL (r=0.81), although in PPH this correlation was poor (r=0.64). These data showed that the distorted left ventricular due to right ventricular overload maintains its global function with preserved function of the free-wall side. (J.P.N.)

  19. Relationship between Fibrosis and Ventricular Arrhythmias in Chagas Heart Disease Without Ventricular Dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Tassi, Eduardo Marinho, E-mail: etassi@ibest.com.br [Instituto de Cardiologia Edson Saad - Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil); Continentino, Marcelo Abramoff [Hospital Frei Galvão, Guaratinguetá, SP (Brazil); Nascimento, Emília Matos do; Pereira, Basílio de Bragança [Instituto de Cardiologia Edson Saad - Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil); Coppe - Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia - UFRJ, Rio de Janeiro, RJ (Brazil); Pedrosa, Roberto Coury [Instituto de Cardiologia Edson Saad - Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil)

    2014-05-15

    Patients with Chagas disease and segmental wall motion abnormality (SWMA) have worse prognosis independent of left ventricular ejection fraction (LVEF). Cardiac magnetic resonance (CMR) is currently the best method to detect SWMA and to assess fibrosis. To quantify fibrosis by using late gadolinium enhancement CMR in patients with Chagas disease and preserved or minimally impaired ventricular function (> 45%), and to detect patterns of dependence between fibrosis, SWMA and LVEF in the presence of ventricular arrhythmia. Electrocardiogram, treadmill exercise test, Holter and CMR were carried out in 61 patients, who were divided into three groups as follows: (1) normal electrocardiogram and CMR without SWMA; (2) abnormal electrocardiogram and CMR without SWMA; (3) CMR with SWMA independently of electrocardiogram. The number of patients with ventricular arrhythmia in relation to the total of patients, the percentage of fibrosis, and the LVEF were, respectively: Group 1, 4/26, 0.74% and 74.34%; Group 2, 4/16, 3.96% and 68.5%; and Group 3, 11/19, 14.07% and 55.59%. Ventricular arrhythmia was found in 31.1% of the patients. Those with and without ventricular arrhythmia had mean LVEF of 59.87% and 70.18%, respectively, and fibrosis percentage of 11.03% and 3.01%, respectively. Of the variables SWMA, groups, age, LVEF and fibrosis, only the latter was significant for the presence of ventricular arrhythmia, with a cutoff point of 11.78% for fibrosis mass (p < 0.001). Even in patients with Chagas disease and preserved or minimally impaired ventricular function, electrical instability can be present. Regarding the presence of ventricular arrhythmia, fibrosis is the most important variable, its amount being proportional to the complexity of the groups.

  20. Relationship between Fibrosis and Ventricular Arrhythmias in Chagas Heart Disease Without Ventricular Dysfunction

    International Nuclear Information System (INIS)

    Tassi, Eduardo Marinho; Continentino, Marcelo Abramoff; Nascimento, Emília Matos do; Pereira, Basílio de Bragança; Pedrosa, Roberto Coury

    2014-01-01

    Patients with Chagas disease and segmental wall motion abnormality (SWMA) have worse prognosis independent of left ventricular ejection fraction (LVEF). Cardiac magnetic resonance (CMR) is currently the best method to detect SWMA and to assess fibrosis. To quantify fibrosis by using late gadolinium enhancement CMR in patients with Chagas disease and preserved or minimally impaired ventricular function (> 45%), and to detect patterns of dependence between fibrosis, SWMA and LVEF in the presence of ventricular arrhythmia. Electrocardiogram, treadmill exercise test, Holter and CMR were carried out in 61 patients, who were divided into three groups as follows: (1) normal electrocardiogram and CMR without SWMA; (2) abnormal electrocardiogram and CMR without SWMA; (3) CMR with SWMA independently of electrocardiogram. The number of patients with ventricular arrhythmia in relation to the total of patients, the percentage of fibrosis, and the LVEF were, respectively: Group 1, 4/26, 0.74% and 74.34%; Group 2, 4/16, 3.96% and 68.5%; and Group 3, 11/19, 14.07% and 55.59%. Ventricular arrhythmia was found in 31.1% of the patients. Those with and without ventricular arrhythmia had mean LVEF of 59.87% and 70.18%, respectively, and fibrosis percentage of 11.03% and 3.01%, respectively. Of the variables SWMA, groups, age, LVEF and fibrosis, only the latter was significant for the presence of ventricular arrhythmia, with a cutoff point of 11.78% for fibrosis mass (p < 0.001). Even in patients with Chagas disease and preserved or minimally impaired ventricular function, electrical instability can be present. Regarding the presence of ventricular arrhythmia, fibrosis is the most important variable, its amount being proportional to the complexity of the groups

  1. Nanometer-sized emissions from municipal waste incinerators: A qualitative risk assessment

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, David R., E-mail: david.r.johnson@ghd.com

    2016-12-15

    Municipal waste incinerators (MWI) are beneficial alternatives to landfills for waste management. A recent constituent of concern in emissions from these facilities is incidental nanometer-sized particles (INP{sub MWI}), i.e., particles smaller than 1 micrometer in size that may deposit in the deepest parts of the lungs, cross into the bloodstream, and affect different regions of the body. With limited data, the public may fear INP{sub MWI} due to uncertainty, which may affect public acceptance, regulatory permitting, and the increased lowering of air quality standards. Despite limited data, a qualitative risk assessment paradigm can be applied to determine the relative risk due to INP{sub MWI} emissions. This review compiles existing data on nanometer-sized particle generation by MWIs, emissions control technologies used at MWIs, emission releases into the atmosphere, human population exposure, and adverse health effects of nanometer-sized particles to generate a qualitative risk assessment and identify data gaps. The qualitative risk assessment conservatively concludes that INP{sub MWI} pose a low to moderate risk to individuals, primarily due to the lack of relevant toxicological data on INP{sub MWI} mixtures in ambient particulate matter.

  2. Developing an interactive portion size assessment system (IPSAS) for use with children.

    Science.gov (United States)

    Foster, E; Hawkins, A; Simpson, E; Adamson, A J

    2014-01-01

    Novel methods of assessing dietary intake are required to reduce the participant burden in dietary surveys, improve participation rates and thereby improve the representativeness of the sample and minimise the impact of measuring dietary intake on a subject's food intake during the recording period. One method of reducing the burden placed on participants in recording dietary intake is to replace weighing of foods with estimation of portion size using tools such as food photographs. The interactive portion size assessment system (IPSAS) is an interactive portion size assessment system for use in assessing portion sizes of foods consumed by children aged 18 months to 16 years. The system is computer-based and is designed to be administered during an interview for a food diary or 24-h recall. The portion sizes depicted are age-specific and based on the weights of foods served to children during the UK National Diet and Nutrition Surveys. The system displays digital images of food used to estimate the amount of each food served to the child and the amount of any food left over. Foods are categorised within the system using a three-tier structure. Twenty-seven food group icons are used with two further drop-down menus to select first the food group, then the food category and, finally, the actual food product. Each food is linked to UK food composition codes and all photographs are linked to the weight of the food depicted. Nutritional output is via a companion database. The present study describes the development of the IPSAS and the structure of the system. © 2013 The Authors Journal of Human Nutrition and Dietetics © 2013 The British Dietetic Association Ltd.

  3. Methods of assessing the functional status of patients with left ventricular systolic dysfunction in interventional studies: can brain natriuretic peptide measurement be used as surrogate for the traditional methods?

    DEFF Research Database (Denmark)

    Abdulla, Jawdat; Køber, Lars; Torp-Pedersen, Christian

    2004-01-01

    AIM: To review whether brain natriuretic peptides (BNP) can be used as a surrogate for the traditional methods of assessing functional status in interventional studies of patients with left ventricular systolic dysfunction (LVSD). METHODS AND RESULTS: The traditional methods for assessing...... functional status including New York Heart Association (NYHA) class, exercise intolerance and quality of life were reviewed in relation to BNP measurements in patients with LVSD. A meta-analysis of four studies evaluating BNP levels versus exercise peak oxygen uptake or 6-minute walking distance showed...

  4. Environmental assessment of sewer construction in small to medium sized cities using life cycle assessment

    OpenAIRE

    Petit, Anna

    2014-01-01

    In a world with an increasing urban population, analysing the construction impacts of sanitation infrastructures through Life Cycle Assessment (LCA) is necessary for defining the best environmental management strategies. In this study, the environmental impacts of one linear meter of sewer constructive solution were analysed for different pipe materials and diameters used in Southern Europe; a unit of different sewer appurtenances (pump, manhole and inspection chamber) was also considered. Th...

  5. Delayed-enhancement MRI of apical hypertrophic cardiomyopathy: assessment of the intramural distribution and comparison with clinical symptoms, ventricular arrhythmias, and cine MRI

    International Nuclear Information System (INIS)

    Amano, Yasuo; Fukushima, Yoshimitsu; Kumita, Shinichiro; Takayama, Morimasa; Kitamura, Mitsunobu

    2011-01-01

    Background: Hypertrophic cardiomyopathy (HCM) is reported to show patchy midwall myocardial hyper enhancement on delayed-enhancement magnetic resonance imaging (DE-MRI). The intramural distribution of myocardial hyper enhancement and its correlation with clinical symptoms, ventricular arrhythmias, and cardiac function have not been described for symptomatic apical HCM. Purpose: To evaluate the features and significance of myocardial hyper enhancement on DE-MRI in symptomatic apical HCM. Material and Methods: Thirteen patients with symptomatic apical HCM and their 65 apical segments were investigated. Myocardial hyper enhancement and regional and global functional parameters were determined with MRI. We investigated the intramural distribution and frequencies of this myocardial hyper enhancement and compared them with the patients' clinical symptoms, the presence of ventricular arrhythmias, and cine MRI. Results: Eight (61.5%) patients with symptomatic apical HCM displayed apical myocardial hyper enhancement, and 22 (33.8%) of the 65 apical segments examined showed myocardial hyper enhancement. Of the myocardial hyper enhancement observed, 81.8% showed a subendocardial pattern.The Hyperenhanced apical myocardium had a lower percentage of systolic myocardial thickening, and was associated with serious symptoms (e.g. syncope) and ventricular arrhythmias. Conclusion: Patients with symptomatic apical HCM showed myocardial hyper enhancement involving the subendocardial layer, which might be related to regional systolic dysfunction, serious clinical symptoms, and ventricular arrhythmias

  6. Short-term assessment of left ventricular function, coronary hemodynamics, and catecholamine balance in severe congestive heart failure after a single oral dose of milrinone

    NARCIS (Netherlands)

    F. Piscione; B.E. Jaski; P.W.J.C. Serruys (Patrick)

    1988-01-01

    textabstractSystemic and coronary hemodynamics were measured before and every 10 min after oral milrinone (10 mg) administration for 50 min, together with the drug plasma level in 14 patients with congestive heart failure. Left ventricular pressure (tip manometry), volume (angiography), and derived

  7. Risk assessment and comparative effectiveness of left ventricular assist device and medical management in ambulatory heart failure patients: design and rationale of the ROADMAP clinical trial.

    Science.gov (United States)

    Rogers, Joseph G; Boyle, Andrew J; O'Connell, John B; Horstmanshof, Douglas A; Haas, Donald C; Slaughter, Mark S; Park, Soon J; Farrar, David J; Starling, Randall C

    2015-02-01

    Mechanical circulatory support is now a proven therapy for the treatment of patients with advanced heart failure and cardiogenic shock. The role for this therapy in patients with less severe heart failure is unknown. The objective of this study is to examine the impact of mechanically assisted circulation using the HeartMate II left ventricular assist device in patients who meet current US Food and Drug Administration-defined criteria for treatment but are not yet receiving intravenous inotropic therapy. This is a prospective, nonrandomized clinical trial of 200 patients treated with either optimal medical management or a mechanical circulatory support device. This trial will be the first prospective clinical evaluation comparing outcomes of patients with advanced ambulatory heart failure treated with either ongoing medical therapy or a left ventricular assist device. It is anticipated to provide novel insights regarding relative outcomes with each treatment and an understanding of patient and provider acceptance of the ventricular assist device therapy. This trial will also provide information regarding the risk of events in "stable" patients with advanced heart failure and guidance for the optimal timing of left ventricular assist device therapy. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. N-terminal-pro-brain natriuretic peptide elevations in the course of septic and non-septic shock reflect systolic left ventricular dysfunction assessed by transpulmonary thermodilution

    Directory of Open Access Journals (Sweden)

    A.B. Johan Groeneveld

    2016-03-01

    Conclusions: In septic and non-septic shock, NT-proBNP elevations reflect systolic left ventricular dysfunction and are associated with a poor outcome. They may help recognition of cardiac dysfunction in shock and its management when invasive hemodynamic monitoring is not yet instituted.

  9. Highly-accelerated self-gated free-breathing 3D cardiac cine MRI: validation in assessment of left ventricular function.

    Science.gov (United States)

    Liu, Jing; Feng, Li; Shen, Hsin-Wei; Zhu, Chengcheng; Wang, Yan; Mukai, Kanae; Brooks, Gabriel C; Ordovas, Karen; Saloner, David

    2017-08-01

    This work presents a highly-accelerated, self-gated, free-breathing 3D cardiac cine MRI method for cardiac function assessment. A golden-ratio profile based variable-density, pseudo-random, Cartesian undersampling scheme was implemented for continuous 3D data acquisition. Respiratory self-gating was achieved by deriving motion signal from the acquired MRI data. A multi-coil compressed sensing technique was employed to reconstruct 4D images (3D+time). 3D cardiac cine imaging with self-gating was compared to bellows gating and the clinical standard breath-held 2D cine imaging for evaluation of self-gating accuracy, image quality, and cardiac function in eight volunteers. Reproducibility of 3D imaging was assessed. Self-gated 3D imaging provided an image quality score of 3.4 ± 0.7 vs 4.0 ± 0 with the 2D method (p = 0.06). It determined left ventricular end-systolic volume as 42.4 ± 11.5 mL, end-diastolic volume as 111.1 ± 24.7 mL, and ejection fraction as 62.0 ± 3.1%, which were comparable to the 2D method, with bias ± 1.96 × SD of -0.8 ± 7.5 mL (p = 0.90), 2.6 ± 3.3 mL (p = 0.84) and 1.4 ± 6.4% (p = 0.45), respectively. The proposed 3D cardiac cine imaging method enables reliable respiratory self-gating performance with good reproducibility, and provides comparable image quality and functional measurements to 2D imaging, suggesting that self-gated, free-breathing 3D cardiac cine MRI framework is promising for improved patient comfort and cardiac MRI scan efficiency.

  10. Impact of diastolic dysfunction severity on global left ventricular volumetric filling - assessment by automated segmentation of routine cine cardiovascular magnetic resonance

    Directory of Open Access Journals (Sweden)

    Mendoza Dorinna D

    2010-07-01

    Full Text Available Abstract Objectives To examine relationships between severity of echocardiography (echo -evidenced diastolic dysfunction (DD and volumetric filling by automated processing of routine cine cardiovascular magnetic resonance (CMR. Background Cine-CMR provides high-resolution assessment of left ventricular (LV chamber volumes. Automated segmentation (LV-METRIC yields LV filling curves by segmenting all short-axis images across all temporal phases. This study used cine-CMR to assess filling changes that occur with progressive DD. Methods 115 post-MI patients underwent CMR and echo within 1 day. LV-METRIC yielded multiple diastolic indices - E:A ratio, peak filling rate (PFR, time to peak filling rate (TPFR, and diastolic volume recovery (DVR80 - proportion of diastole required to recover 80% stroke volume. Echo was the reference for DD. Results LV-METRIC successfully generated LV filling curves in all patients. CMR indices were reproducible (≤ 1% inter-reader differences and required minimal processing time (175 ± 34 images/exam, 2:09 ± 0:51 minutes. CMR E:A ratio decreased with grade 1 and increased with grades 2-3 DD. Diastolic filling intervals, measured by DVR80 or TPFR, prolonged with grade 1 and shortened with grade 3 DD, paralleling echo deceleration time (p 80 identified 71% of patients with echo-evidenced grade 1 but no patients with grade 3 DD, and stroke-volume adjusted PFR identified 67% with grade 3 but none with grade 1 DD (matched specificity = 83%. The combination of DVR80 and PFR identified 53% of patients with grade 2 DD. Prolonged DVR80 was associated with grade 1 (OR 2.79, CI 1.65-4.05, p = 0.001 with a similar trend for grade 2 (OR 1.35, CI 0.98-1.74, p = 0.06, whereas high PFR was associated with grade 3 (OR 1.14, CI 1.02-1.25, p = 0.02 DD. Conclusions Automated cine-CMR segmentation can discern LV filling changes that occur with increasing severity of echo-evidenced DD. Impaired relaxation is associated with prolonged

  11. Quantitative assessment of primary mitral regurgitation using left ventricular volumes obtained with new automated three-dimensional transthoracic echocardiographic software: A comparison with 3-Tesla cardiac magnetic resonance.

    Science.gov (United States)

    Levy, Franck; Marechaux, Sylvestre; Iacuzio, Laura; Schouver, Elie Dan; Castel, Anne Laure; Toledano, Manuel; Rusek, Stephane; Dor, Vincent; Tribouilloy, Christophe; Dreyfus, Gilles

    2018-03-30

    Quantitative assessment of primary mitral regurgitation (MR) using left ventricular (LV) volumes obtained with three-dimensional transthoracic echocardiography (3D TTE) recently showed encouraging results. Nevertheless, 3D TTE is not incorporated into everyday practice, as current LV chamber quantification software products are time consuming. To investigate the accuracy and reproducibility of new automated fast 3D TTE software (HeartModel A.I. ; Philips Healthcare, Andover, MA, USA) for the quantification of LV volumes and MR severity in patients with isolated degenerative primary MR; and to compare regurgitant volume (RV) obtained with 3D TTE with a cardiac magnetic resonance (CMR) reference. Fifty-three patients (37 men; mean age 64±12 years) with at least mild primary isolated MR, and having comprehensive 3D TTE and CMR studies within 24h, were eligible for inclusion. MR RV was calculated using the proximal isovelocity surface area (PISA) method and the volumetric method (total LV stroke volume minus aortic stroke volume) with either CMR or 3D TTE. Inter- and intraobserver reproducibility of 3D TTE was excellent (coefficient of variation≤10%) for LV volumes. MR RV was similar using CMR and 3D TTE (57±23mL vs 56±28mL; P=0.22), but was significantly higher using the PISA method (69±30mL; P<0.05 compared with CMR and 3D TTE). The PISA method consistently overestimated MR RV compared with CMR (bias 12±21mL), while no significant bias was found between 3D TTE and CMR (bias 2±14mL). Concordance between echocardiography and CMR was higher using 3D TTE MR grading (intraclass correlation coefficient [ICC]=0.89) than with PISA MR grading (ICC=0.78). Complete agreement with CMR grading was more frequent with 3D TTE than with the PISA method (76% vs 63%). 3D TTE RV assessment using the new generation of automated software correlates well with CMR in patients with isolated degenerative primary MR. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  12. ONE APPROACH TO ASSESSING THE SIZE AND CAPACITY OF THE MARKET

    Directory of Open Access Journals (Sweden)

    Anatoly V. Korotkov

    2013-01-01

    Full Text Available The aim of the article is to study the economic and statistical essence and development of methods of calculation of the market’s size and capacity. Described further material is focused on experts on statistics of the market of goods and services, as well as marketers. Evaluation of size and capacity market is an extremely demanded in practice. However, a review of publications, scientific direction of research is the size and capacity of the market is not yet complete. Researchers are working to develop new approaches to the assessment of the market and to develop relevant procedures. Problems arise distinction between the notions of demand and market capacity. Theoretical basis of the research are the provisions of the economic theory, statistics of the market of goods and services, and marketing.

  13. Electrocardiographic infarct size assessment after thrombolysis: insights from the Acute Myocardial Infarction STudy ADenosine (AMISTAD) trial.

    Science.gov (United States)

    Barbagelata, Alejandro; Di Carli, Marcelo F; Califf, Robert M; Garg, Jyotsna; Birnbaum, Yochai; Grinfeld, Liliana; Gibbons, Raymond J; Granger, Christopher B; Goodman, Shaun G; Wagner, Galen S; Mahaffey, Kenneth W

    2005-10-01

    Noninvasive methods are needed to evaluate reperfusion success in patients with acute myocardial infarction (MI). The AMISTAD trial was analyzed to compare MI size and myocardial salvage determined by electrocardiogram (ECG) with technetium Tc 99m sestamibi single-photon emission computerized tomography (SPECT) imaging. Of 236 patients enrolled in AMISTAD, 166 (70 %) with no ECG confounding factors and no prior MI were included in this analysis. Of these, group 1 (126 patients, 53%) had final infarct size (FIS) available by both ECG and SPECT. Group 2 (56 patients, 24%) had myocardium at risk, FIS, and salvage index (SI) assessed by both SPECT and ECG techniques. Aldrich/Clemmensen scores for myocardium at risk and the Selvester QRS score for final MI size were used. Salvage index was calculated as follows: SI = (myocardium at risk-FIS)/(myocardium at risk). In group 1, FIS was 15% (6, 24) as measured by ECG and 11% (2, 27) as measured by SPECT. In the adenosine group, FIS was 12% (6, 21) and 11% (2, 22). In the placebo group, FIS was 16.5% (7.5, 24) and 11.5% (3.0, 38.5) by ECG and SPECT, respectively. The overall correlation between SPECT and ECG for FIS was 0.58 (P = .0001): 0.60 in the placebo group (P = .0001) and 0.54 (P = .0001) in the adenosine group. In group 2, myocardium at risk was 23% (17, 30) and 26% (10, 50) with ECG and SPECT, respectively (P = .0066). Final infarct size was 17% (6, 21) and 12% (1, 24) (P < .0001). The SI was 29% (-7, 57) and 46% (15, 79) with ECG and SPECT, respectively (P = .0510). The ECG measurement of infarct size has a moderate relationship with SPECT infarct size measurements in the population with available assessments. This ECG algorithm must further be validated on clinical outcomes.

  14. Assessment of relative individual renal function based on DMSA uptake corrected for renal size

    International Nuclear Information System (INIS)

    Estorch, M.; Camacho, V.; Tembl, A.; Mena, I.; Hernandez, A.; Flotats, A.; Carrio, I.; Torres, G.; Prat, L.

    2002-01-01

    Decreased relative renal DMSA uptake can be a consequence of abnormal kidney size, associated with normal or impaired renal function. The quantification of relative renal function based on DMSA uptake in both kidneys is an established method for the assessment of individual renal function. Aim: To assess relative renal function by means of quantification of renal DMSA uptake corrected for kidney size. Results were compared with relative renal DMSA uptake without size correction, and were validated against the absolute renal DMSA uptake. Material and Methods: Four-hundred-forty-four consecutive patients (147 adults, mean age 14 years) underwent a DMSA study for several renal diseases. The relative renal function, based on the relative DMSA uptake uncorrected and corrected for renal size, and the absolute renal DMSA uptake were calculated. In order to relate the relative DMSA uptake uncorrected and corrected for renal size with the absolute DMSA uptake, subtraction of uncorrected (SU) and corrected (SC) relative uptake percentages of each pair of kidneys was obtained, and these values were correlated to the matched subtraction percentages of absolute uptake (SA). If the individual relative renal function is normal (45%-55%), the subtraction value is less or equal to 10%. Results: In 227 patients (51%) the relative renal DMSA uptake value was normal either uncorrected or corrected for renal size (A), and in 149 patients (34%) it was abnormal by both quantification methods (B). Seventy-seven patients (15%) had the relative renal DMSA uptake abnormal only by the uncorrected method (C). Subtraction value of absolute DMSA uptake percentages was not significantly different of subtraction value of relative DMSA uptake percentages corrected for renal size when relative uncorrected uptake was abnormal and corrected normal. where * p<0.0001, and p=NS. Conclusion: When uncorrected and corrected relative DMSA uptake are abnormal, the absolute uptake is also impaired, while when

  15. A toughness and defect size assessment of welded stainless steel components

    International Nuclear Information System (INIS)

    Chipperfield, C.G.

    1978-01-01

    The results of an investigation of the effect of test temperature, stress relieving temperature and weld profile on the initiation toughness of 316 type steels are described. The data indicate that little improvement in weld metal toughness is obtained by stress relieving at temperatures of up to 850 0 C and the magnitude of the toughness is significantly below that of wrought 316 steel. The observed trends in toughness with test temperature or stress relieving temperature have been explained in terms of the effect of these variables on yield strength and work hardening rate. A defect size assessment of a particular component has been made for stress relieved and non-stress relieved conditions. Simple addition of residual to applied stress values indicated that the defect size is in many cases essentially controlled by the magnitude of the residual stress. The possible conservatism of this assessment and the use of initiation toughness values are discussed. (author)

  16. Use of the truncated shifted Pareto distribution in assessing size distribution of oil and gas fields

    Science.gov (United States)

    Houghton, J.C.

    1988-01-01

    The truncated shifted Pareto (TSP) distribution, a variant of the two-parameter Pareto distribution, in which one parameter is added to shift the distribution right and left and the right-hand side is truncated, is used to model size distributions of oil and gas fields for resource assessment. Assumptions about limits to the left-hand and right-hand side reduce the number of parameters to two. The TSP distribution has advantages over the more customary lognormal distribution because it has a simple analytic expression, allowing exact computation of several statistics of interest, has a "J-shape," and has more flexibility in the thickness of the right-hand tail. Oil field sizes from the Minnelusa play in the Powder River Basin, Wyoming and Montana, are used as a case study. Probability plotting procedures allow easy visualization of the fit and help the assessment. ?? 1988 International Association for Mathematical Geology.

  17. Arrhythmogenic right ventricular dysplasia

    International Nuclear Information System (INIS)

    Vignolo Puglia, W.; Freire Colla, D.; Rivara Urrutia, D.; Lujambio Grene, M.; Arbiza Bruno, T.; Oliveira, G.; Cobas Rodriguez, J.

    1997-01-01

    The arrhythmogenic right ventricular dysplasia is a condition predominantly well defined with arrhythmic events. We analyze three cases diagnosed by the group. These cases were presented as ventricular tachycardia with a morphology of left bundle branch block, presenting one of them aborted sudden death in evolution. The baseline electrocardiogram and signal averaging were abnormal in two of the three cases, like the echocardiogram. The electrophysiological study was able to induce in the three patients with sustained monomorphic ventricular tachycardia morphology of left bundle branch block. The definitive diagnosis was made by right ventriculography in two cases and magnetic resonance imaging in the other. Treatment included antiarrhythmic drugs in the three cases and the placement of an automatic defibrillator which survived a sudden death (Author)

  18. MR assessment of the repaired rotator cuff: prevalence, size, location, and clinical relevance of tendon rerupture

    International Nuclear Information System (INIS)

    Mellado, J.M.; Calmet, J.; Ballabriga, J.; Gine, J.; Olona, M.; Camins, A.; Perez del Palomar, L.

    2006-01-01

    The objectives of this study were to use magnetic resonance (MR) imaging to evaluate the prevalence, size, location, and clinical relevance of tendon rerupture following complete repair of full-thickness rotator cuff tear (RCT). A total of 78 surgically proven full-thickness rotator cuff tears in 74 patients were retrospectively included in the study. Clinical assessment was performed using the University of California at Los Angeles score. Postoperative MR imaging was evaluated to determine prevalence, size, and location of tendon rerupture. At a mean 48.4 months' follow-up, 62 shoulders (79.5%) had favorable outcomes and 45 shoulders (57.6%) showed rerupture on MR imaging studies. Reruptures were significantly more prevalent among patients with intermediate-to-bad outcomes (81.3%), with surgically demonstrated two-tendon tears (78.9%) or three-tendon tears (100%), and with preoperative fatty degeneration of the supraspinatus muscle greater than 1 (91.6%). Reruptures were also significantly larger in those subgroups. Complete repair of RCT of all sizes may have favorable outcomes in a significant proportion of patients in spite of a high prevalence of reruptures. Preoperative tear size and degree of muscle fatty degeneration influence the prevalence and rerupture size. After repair of supraspinatus tears, reruptures tend to invade the posterior aspect of the tendon. (orig.)

  19. MR assessment of the repaired rotator cuff: prevalence, size, location, and clinical relevance of tendon rerupture

    Energy Technology Data Exchange (ETDEWEB)

    Mellado, J.M. [Hospital Reina Sofia de Tudela, Servicio de Radiodiagnostico, Tudela, Navarra (Spain); Calmet, J.; Ballabriga, J.; Gine, J. [Hospital Universitari de Tarragona Joan XXIII, Servei de Cirurgia Ortopedica i Traumatologia, Tarragona (Spain); Olona, M. [Hospital Universitari de Tarragona Joan XXIII, Servei de Medicina Preventiva i Epidemiologia, Tarragona (Spain); Camins, A. [Hospital Universitari de Tarragona Joan XXIII, Institut de Diagnostic per la Imatge, Tarragona (Spain); Perez del Palomar, L. [Hospital Ernest Lluch, Servicio de Radiologia, Calatayud, Zaragoza (Spain)

    2006-10-15

    The objectives of this study were to use magnetic resonance (MR) imaging to evaluate the prevalence, size, location, and clinical relevance of tendon rerupture following complete repair of full-thickness rotator cuff tear (RCT). A total of 78 surgically proven full-thickness rotator cuff tears in 74 patients were retrospectively included in the study. Clinical assessment was performed using the University of California at Los Angeles score. Postoperative MR imaging was evaluated to determine prevalence, size, and location of tendon rerupture. At a mean 48.4 months' follow-up, 62 shoulders (79.5%) had favorable outcomes and 45 shoulders (57.6%) showed rerupture on MR imaging studies. Reruptures were significantly more prevalent among patients with intermediate-to-bad outcomes (81.3%), with surgically demonstrated two-tendon tears (78.9%) or three-tendon tears (100%), and with preoperative fatty degeneration of the supraspinatus muscle greater than 1 (91.6%). Reruptures were also significantly larger in those subgroups. Complete repair of RCT of all sizes may have favorable outcomes in a significant proportion of patients in spite of a high prevalence of reruptures. Preoperative tear size and degree of muscle fatty degeneration influence the prevalence and rerupture size. After repair of supraspinatus tears, reruptures tend to invade the posterior aspect of the tendon. (orig.)

  20. Examples from P2 and energy assessments at small to medium size manufacturers

    International Nuclear Information System (INIS)

    Fleischman, M.; Watters, J.C.; Cobourn, W.G.; Collins, D.J.

    1996-01-01

    Using engineering student-faculty teams, the U.S. Department of energy sponsored industrial assessment center (IAC) at the university of louisville does free pollution prevention and energy assessments at small to medium size manufacturers (SIC 20-39) in kentucky and indiana. Each client plant must meet three of the following four criteria: Annual energy bills less than $1, 750, 000 and more than $50, 00. Gross annual sales of less than $75 million. Less than 500 employees. Lack a dedicated energy/waste engineer. Lack of in-house staff to perform these analyses. The program criteria and assessment procedures are briefly described and summaries of assessment at a sheet fed offset (lithographic) printing plant and 2 denim jeans pre washing plants are presented. 4 figs., 8 tabs

  1. Comparison of gated blood pool SPECT and spiral multidetector computed tomography in the assessment of right ventricular functional parameters. Validation with first-pass radionuclide angiography

    International Nuclear Information System (INIS)

    Lee, Jung S.; Kim, Seong-Jang; Kim, In-Ju; Kim, Yong-Ki; Choo, Ki S.; Lee, Jun S.

    2007-01-01

    The aim of this study was to compare gated blood pool single photon emission computed tomography (SPECT) (GBPS) and multidetector row computed tomography (MDCT) for the determination of right ventricular ejection fraction (RVEF) and right ventricular volumes (RVV) and to compare first-pass radionuclide angiography (FP-RNA) as the gold standard. Twenty consecutive patients (11 men, 9 women) referred for MDCT for the evaluation of the presence of coronary artery disease underwent FP-RNA and GBPS. The mean right ventricular end-diastolic volume (EDV) calculated with GBPS revealed a statistically significant lower value than that of MDCT. The mean right ventricular end-systolic volume (ESV) calculated with GBPS was also lower than that of MDCT. A comparison of right ventricular EDV from GBPS and MDCT yielded a correlation coefficient of 0.5972. Right ventricular ESV between GBPS and MDCT showed a correlation coefficient of 0.5650. The mean RVEFs calculated with FP-RNA (39.8%±4.0%), GBPS (43.7%±6.9%), and MDCT (40.4%±7.7%) showed no statistical differences (Kruskal-Wallis statistics 4.538, P=0.1034). A comparison of RVEFs from FP-RNA and GBPS yielded a correlation coefficient of 0.7251; RVEFs between FP-RNA and MDCT showed a correlation coefficient of 0.6166 and between GBPS and MDCT showed a correlation coefficient of 0.6367. The RVEF, EDV, and ESV calculated by GBPS had good correlation with those obtained with MDCT. In addition, there were no statistical differences of RVEF calculated from FP-RNA, GBPS, and MDCT. However, with regard to RVV, EDV and ESV from GBPS revealed statistically significantly lower values than those of MDCT. Although reasonable correlations among these modalities were obtained, the agreement among these three modalities was not good enough for interchangeable use in the clinical setting. Also, these results should be confirmed in patients with cardiac diseases in future larger population-based studies. (author)

  2. The angulation of the septal structures impacts ventricular imbalance in atrioventricular septal defects with a common atrioventricular junction.

    Science.gov (United States)

    Ahmad, Zaheer; Lim, Zek; Roman, Kevin; Haw, Marcus; Anderson, Robert H; Vettukattil, Joseph

    2016-02-01

    Multiplanar re-formatting of full-volume three-dimensional echocardiography data sets offers new insights into the morphology of atrioventricular septal defects. We hypothesised that distortion of the alignment between the atrial and ventricular septums results in imbalanced venous return to the ventricles, with consequent proportional ventricular hypoplasia. A single observer evaluated 31 patients, with a mean age of 52.09 months, standard deviation of 55, and with a range from 2 to 264 months, with atrioventricular septal defects, of whom 17 were boys. Ventricular imbalance, observed in nine patients, was determined by two-dimensional assessment, and confirmed at surgical inspection in selected cases when a univentricular strategy was undertaken. Offline analysis using multiplanar re-formatting was performed. A line was drawn though the length of the ventricular septum and a second line along the plane of the atrial septum, taking the angle between these two lines as the atrioventricular septal angle. We compared the angle between 22 patients with adequately sized ventricles, and those with ventricular imbalance undergoing univentricular repair. In the 22 patients undergoing biventricular repair, the septal angle was 0 in 14 patients; the other eight patients having angles ranging from 1 to 36, with a mean angle of 7.4°, and standard deviation of 11.1°.The mean angle in the nine patients with ventricle imbalance was 28.6°, with a standard deviation of 3.04°, and with a range from 26 to 35°. Of those undergoing univentricular repair, two patients died, with angles of 26 and 30°, respectively. The atrioventricular septal angle derived via multiplanar formatting gives important information regarding the degree of ventricular hypoplasia and imbalance. When this angle is above 25°, patients are likely to have ventricular imbalance requiring univentricular repair.

  3. Evaluation of Right Ventricular Function with Radionuclide Cardiac Angiography - Right Ventricular Ejection Fraction in Chronic Obstructive Lung Disease

    International Nuclear Information System (INIS)

    Sohn, In; Shin, Sung Hae; Chung, June Key; Lee, Myung Chul; Cho, Bo Youn; Lee, Young Woo; Han, Yong Cheol; Koh, Chang Soon

    1982-01-01

    To evaluate the usefulness of radionuclide cardiac angiography in the assessment of the right ventricular function, we measured right ventricular ejection fraction (RVEF) using single pass method. In 12 normal persons, RVEF averaged 52.7±5.9% (mean±S.D.). In 25 patients with chronic obstructive lung disease, RVEF was 37.2±10.6% and significantly lower than that of normal person (p<0.01). All 10 patients with right ventricular failure had abnormal RVEF, which was significantly lower than that of 14 persons without right ventricular failure (27.6±5.7%, 43.9±8.5%, respectively, p<0.01). It concluded that RVEF measured by single pass radionuclide cardiac angiography was a useful, noninvasive method to assess right ventricular function.

  4. Evaluation of left ventricular function using digital subtraction ventriculography

    International Nuclear Information System (INIS)

    Yiannikas, J.; Detrano, R.

    1986-01-01

    Digital subtraction ventriculography following injections of contrast via peripheral veins provides excellent images to assess left ventricular function. The images are essentially identical to those following DCV, but allow more uniform mixing of contrast in the left ventricular chamber. Furthermore, few, if any, cardiac arrhythmias occur, hence obviating difficulties that arise from DCV. The spatial resolution of the method is such that regional wall motion assessment of ventricular function is more accurate than that of other noninvasive imaging methods. The use of video-densitometry allows accurate assessment of left ventricular function even when the left ventricular cavity is nonsymmetrically deformed and aneurysmal. In the setting of the cardiac catheterization laboratory, digital ventriculography may provide a safer means of assessing left ventricular function when critical coronary or myocardial disease is present and allows multiple assessments of ventricular function during the same study. Although excellent correlations with standard ventriculography have been noted by all workers, significant discrepancies still exist in individual patients, particularly in the calculations of end diastolic volumes. In the authors experience and in those of most workers, the largest discrepancies existed in patients in whom suboptimal studies are included for analysis. The most frequent reason for the occasional suboptimal study as with all digital subtraction work is the misregistration that results from motion

  5. ASSESSMENT OF KNOWLEDGE REGARDING FAMILY PLANNING METHODS AND INTENDED FAMILY SIZE AMONG MEN OF URBAN SLUM

    Directory of Open Access Journals (Sweden)

    Anand Mohan Dixit

    2013-12-01

    Full Text Available Objective: To assess the knowledge of contraceptive methods and intended family size among the men of urban slum.Material and Method: Present study conducted in urban slum area of Jaipur. Information from 400 married men of age group 18-49 years collected on semi structured schedule during June to October 2012.House to house survey conducted to achieve defined sample size. Data were analyzed by using SPSS 12 soft ware. Chi square, t test and ANOVA were used for interpretation.Result and Conclusion: Most commonly known methods of family planning were female sterilization (95.2%, condom (94.7% and Male sterilization (93.5%.  IUCD (57% was still not popularly known method of contraception. Emergency contraceptive pills (12.2% and Injectables (25.7% were least known methods among men. Knowledge of different contraceptive differs according to educational status and caste of men.  TV and radio were main source of information. Only 16% men said that they got information from health personnel. On analysis present family size was 3.125 while desired family size was 2.63, it shows that two child norm is not ideal to all. Men who had already two children 53 % of them still want to expand their family. Approximately half of the men feel that they have larger family size and the main reasons were inappropriate knowledge (37% and ignorance (21%. Those men who want to expand their family size, son preference was the major reason. Only 3% men show the intention of one child as ideal in family, which indicate that one child norm is too far to reach.

  6. ASSESSMENT OF KNOWLEDGE REGARDING FAMILY PLANNING METHODS AND INTENDED FAMILY SIZE AMONG MEN OF URBAN SLUM

    Directory of Open Access Journals (Sweden)

    Anand Mohan Dixit

    2013-09-01

    Full Text Available Objective: To assess the knowledge of contraceptive methods and intended family size among the men of urban slum.Material and Method: Present study conducted in urban slum area of Jaipur. Information from 400 married men of age group 18-49 years collected on semi structured schedule during June to October 2012.House to house survey conducted to achieve defined sample size. Data were analyzed by using SPSS 12 soft ware. Chi square, t test and ANOVA were used for interpretation.Result and Conclusion: Most commonly known methods of family planning were female sterilization (95.2%, condom (94.7% and Male sterilization (93.5%.  IUCD (57% was still not popularly known method of contraception. Emergency contraceptive pills (12.2% and Injectables (25.7% were least known methods among men. Knowledge of different contraceptive differs according to educational status and caste of men.  TV and radio were main source of information. Only 16% men said that they got information from health personnel. On analysis present family size was 3.125 while desired family size was 2.63, it shows that two child norm is not ideal to all. Men who had already two children 53 % of them still want to expand their family. Approximately half of the men feel that they have larger family size and the main reasons were inappropriate knowledge (37% and ignorance (21%. Those men who want to expand their family size, son preference was the major reason. Only 3% men show the intention of one child as ideal in family, which indicate that one child norm is too far to reach.

  7. Echocardiographic assessment of right ventricular function in routine practice: Which parameters are useful to predict one-year outcome in advanced heart failure patients with dilated cardiomyopathy?

    Science.gov (United States)

    Kawata, Takayuki; Daimon, Masao; Kimura, Koichi; Nakao, Tomoko; Lee, Seitetsu L; Hirokawa, Megumi; Kato, Tomoko S; Watanabe, Masafumi; Yatomi, Yutaka; Komuro, Issei

    2017-10-01

    Right ventricular (RV) function has recently gained attention as a prognostic predictor of outcome even in patients who have left-sided heart failure. Since several conventional echocardiographic parameters of RV systolic function have been proposed, our aim was to determine if any of these parameters (tricuspid annular plane systolic excursion: TAPSE, tissue Doppler derived systolic tricuspid annular motion velocity: S', fractional area change: FAC) are associated with outcome in advanced heart failure patients with dilated cardiomyopathy (DCM). We retrospectively enrolled 68 DCM patients, who were New York Heart Association (NYHA) Class III or IV and had a left ventricular (LV) ejection fraction functional class IV, plasma brain natriuretic peptide concentration, intravenous inotrope use, left atrial volume index, and FAC were associated with outcome, whereas TAPSE and S' were not. Receiver-operating characteristic curve analysis showed that the optimal FAC cut-off value to identify patients with an event was rights reserved.

  8. Relation between N-terminal pro-brain natriuretic peptide and cardiac remodeling and function assessed by cardiovascular magnetic resonance imaging in patients with arrhythmogenic right ventricular cardiomyopathy.

    Science.gov (United States)

    Cheng, Huaibing; Lu, Minjie; Hou, Cuihong; Chen, Xuhua; Wang, Jing; Yin, Gang; Chu, Jianmin; Zhang, Shu; Prasad, Sanjay K; Pu, Jielin; Zhao, Shihua

    2015-02-01

    Although N-terminal pro-brain natriuretic peptide (NT-proBNP) is a useful screening test of impaired right ventricular (RV) function in conditions affecting the right-sided cardiac muscle, the role of NT-proBNP remains unclear in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC). This study was designed to clarify the relation between the plasma NT-proBNP level and the RV function evaluated by cardiovascular magnetic resonance (CMR) imaging. We selected 56 patients with confirmed ARVC only when their blood specimens for NT-proBNP measurements were collected within 48 hours of a CMR scan. The NT-proBNP level was significantly higher in patients with RV dysfunction than in patients without RV dysfunction (median of 655.3 [interquartile range 556.4 to 870.0] vs 347.0 [interquartile range 308.0 to 456.2] pmol/L, p rights reserved.

  9. Threshold-dependent sample sizes for selenium assessment with stream fish tissue

    Science.gov (United States)

    Hitt, Nathaniel P.; Smith, David R.

    2015-01-01

    Natural resource managers are developing assessments of selenium (Se) contamination in freshwater ecosystems based on fish tissue concentrations. We evaluated the effects of sample size (i.e., number of fish per site) on the probability of correctly detecting mean whole-body Se values above a range of potential management thresholds. We modeled Se concentrations as gamma distributions with shape and scale parameters fitting an empirical mean-to-variance relationship in data from southwestern West Virginia, USA (63 collections, 382 individuals). We used parametric bootstrapping techniques to calculate statistical power as the probability of detecting true mean concentrations up to 3 mg Se/kg above management thresholds ranging from 4 to 8 mg Se/kg. Sample sizes required to achieve 80% power varied as a function of management thresholds and Type I error tolerance (α). Higher thresholds required more samples than lower thresholds because populations were more heterogeneous at higher mean Se levels. For instance, to assess a management threshold of 4 mg Se/kg, a sample of eight fish could detect an increase of approximately 1 mg Se/kg with 80% power (given α = 0.05), but this sample size would be unable to detect such an increase from a management threshold of 8 mg Se/kg with more than a coin-flip probability. Increasing α decreased sample size requirements to detect above-threshold mean Se concentrations with 80% power. For instance, at an α-level of 0.05, an 8-fish sample could detect an increase of approximately 2 units above a threshold of 8 mg Se/kg with 80% power, but when α was relaxed to 0.2, this sample size was more sensitive to increasing mean Se concentrations, allowing detection of an increase of approximately 1.2 units with equivalent power. Combining individuals into 2- and 4-fish composite samples for laboratory analysis did not decrease power because the reduced number of laboratory samples was compensated for by increased

  10. Intracardiac echo-facilitated 3D electroanatomical mapping of ventricular arrhythmias from the papillary muscles: assessing the 'fourth dimension' during ablation.

    Science.gov (United States)

    Proietti, Riccardo; Rivera, Santiago; Dussault, Charles; Essebag, Vidal; Bernier, Martin L; Ayala-Paredes, Felix; Badra-Verdu, Mariano; Roux, Jean-François

    2017-01-01

    Ventricular arrhythmias (VA) originating from a papillary muscle (PM) have recently been described as a distinct clinical entity with peculiar features that make its treatment with catheter ablation challenging. Here, we report our experience using an intracardiac echo-facilitated 3D electroanatomical mapping approach in a case series of patients undergoing ablation for PM VA. Sixteen patients who underwent catheter ablation for ventricular tachycardia (VT) or symptomatic premature ventricular contractions originating from left ventricular PMs were included in the study. A total of 24 procedures (mean 1.5 per patient) were performed: 15 using a retrograde aortic approach and 9 using a transseptal approach. Integrated intracardiac ultrasound for 3D electroanatomical mapping was used in 15 of the 24 procedures. The posteromedial PM was the most frequent culprit for the clinical arrhythmia, and the body was the part of the PM most likely to be the successful site for ablation. The site of ablation was identified based on the best pace map matching the clinical arrhythmia and the site of earliest the activation. At a mean follow-up of 10.5 ± 7 months, only two patients had recurrent arrhythmias following a repeat ablation procedure. An echo-facilitated 3D electroanatomical mapping allows for real-time creation of precise geometries of cardiac chambers and endocavitary structures. This is useful during procedures such as catheter ablation of VAs originating from PMs, which require detailed representation of anatomical landmarks. Routine adoption of this technique should be considered to improve outcomes of PM VA ablation. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  11. Nuclear cardiology. I - Radionuclide angiographic assessment of left ventricular contraction: uses, limitations and future directions. II - The role of myocardial perfusion imaging using thallium-201 in diagnosis of coronary heart disease

    International Nuclear Information System (INIS)

    Bodenheimer, M.M.; Banka, V.S.; Helfant, R.H.; Pennsylvania, University, Philadelphia, PA)

    1980-01-01

    The current status of radionuclide angiography is reviewed. First pass and gated equilibrium methods for determining left ventricular contraction are compared. Some clinical applications of radionuclide angiography are then examined, including the detection of discrete versus diffuse asynergy and the assessment of myocardial infarction. The second part of this work reviews the uses and limitations of thallium-201 perfusion imaging in the diagnosis of the acute and chronic manifestations of coronary heart disease. Theoretical and technical considerations of thallium-201 imaging are reviewed along with the clinical implications of the technique

  12. Raman spectroscopic identification of size-selected airborne particles for quantitative exposure assessment

    International Nuclear Information System (INIS)

    Steer, Brian; Gorbunov, Boris; Price, Mark C; Podoleanu, Adrian

    2016-01-01

    In this paper we present a method for the quantification of chemically distinguished airborne particulate matter, required for health risk assessment. Rather than simply detecting chemical compounds in a sample, we demonstrate an approach for the quantification of exposure to airborne particles and nanomaterials. In line with increasing concerns over the proliferation of engineered particles we consider detection of synthetically produced ZnO crystals. A multi-stage approach is presented whereby the particles are first aerodynamically size segregated from a lab-generated single component aerosol in an impaction sampler. These size fractionated samples are subsequently analysed by Raman spectroscopy. Imaging analysis is applied to Raman spatial maps to provide chemically specific quantification of airborne exposure against background which is critical for health risk evaluation of exposure to airborne particles. Here we present a first proof-of-concept study of the methodology utilising particles in the 2–4 μm aerodynamic diameter range to allow for validation of the approach by comparison to optical microscopy. The results show that the combination of these techniques provides independent size and chemical discrimination of particles. Thereby a method is provided to allow quantitative and chemically distinguished measurements of aerosol concentrations separated into exposure relevant size fractions. (paper)

  13. Female brain size affects the assessment of male attractiveness during mate choice.

    Science.gov (United States)

    Corral-López, Alberto; Bloch, Natasha I; Kotrschal, Alexander; van der Bijl, Wouter; Buechel, Severine D; Mank, Judith E; Kolm, Niclas

    2017-03-01

    Mate choice decisions are central in sexual selection theory aimed to understand how sexual traits evolve and their role in evolutionary diversification. We test the hypothesis that brain size and cognitive ability are important for accurate assessment of partner quality and that variation in brain size and cognitive ability underlies variation in mate choice. We compared sexual preference in guppy female lines selected for divergence in relative brain size, which we have previously shown to have substantial differences in cognitive ability. In a dichotomous choice test, large-brained and wild-type females showed strong preference for males with color traits that predict attractiveness in this species. In contrast, small-brained females showed no preference for males with these traits. In-depth analysis of optomotor response to color cues and gene expression of key opsins in the eye revealed that the observed differences were not due to differences in visual perception of color, indicating that differences in the ability to process indicators of attractiveness are responsible. We thus provide the first experimental support that individual variation in brain size affects mate choice decisions and conclude that differences in cognitive ability may be an important underlying mechanism behind variation in female mate choice.

  14. Empirical assessment of published effect sizes and power in the recent cognitive neuroscience and psychology literature.

    Science.gov (United States)

    Szucs, Denes; Ioannidis, John P A

    2017-03-01

    We have empirically assessed the distribution of published effect sizes and estimated power by analyzing 26,841 statistical records from 3,801 cognitive neuroscience and psychology papers published recently. The reported median effect size was D = 0.93 (interquartile range: 0.64-1.46) for nominally statistically significant results and D = 0.24 (0.11-0.42) for nonsignificant results. Median power to detect small, medium, and large effects was 0.12, 0.44, and 0.73, reflecting no improvement through the past half-century. This is so because sample sizes have remained small. Assuming similar true effect sizes in both disciplines, power was lower in cognitive neuroscience than in psychology. Journal impact factors negatively correlated with power. Assuming a realistic range of prior probabilities for null hypotheses, false report probability is likely to exceed 50% for the whole literature. In light of our findings, the recently reported low replication success in psychology is realistic, and worse performance may be expected for cognitive neuroscience.

  15. Breast tumor size assessment: comparison of conventional ultrasound and contrast-enhanced ultrasound.

    Science.gov (United States)

    Jiang, Yu-Xin; Liu, He; Liu, Ji-Bin; Zhu, Qing-Li; Sun, Qiang; Chang, Xiao-Yan

    2007-12-01

    Accurate assessment of tumor size is necessary when selecting patients for breast-conserving surgery. In the study of breast contrast-enhanced ultrasound (CEUS), we found that tumor size discrepancy between CEUS and conventional ultrasound (US) existed in some breast lesions, for which the reasons are not clear. Breast CEUS examinations were performed in 104 patients with breast lesions. The measurement of the 104 breast tumors on conventional US was obtained and compared with the measurement on CEUS. A difference in measuring tumor size of >3 mm for tumors up to 1.7 cm and 4 mm for tumors >or=1.7 cm, was defined as a significant discrepancy between conventional US and CEUS. The histopathological examination of size discrepancy was performed and the margin characteristics of breast cancers with larger measurements were compared with those with unchanged measurements. Among the 104 lesions (43 malignant, 60 benign, 1 borderline), the size of 27 breast cancers and one granulomatous mastitis appeared larger at CEUS. Pathologic examinations of the region corresponding to the measurement discrepancy were mainly ductal carcinomas in situ (DCIS), invasive carcinoma with a DCIS component, adenosis with lobular hyperplasia in breast cancers and inflammatory cell infiltration in one granulomatous mastitis. Well-defined margin characteristics were significantly different between breast cancers with larger measurements at CEUS and those with unchanged measurements of size (p = 0.002), whereas no significant difference was found between the two groups in ill-defined, spiculated, hyperechoic halo, microlobulated and angulated margins (p = 0.463, 0.117, 0.194, 0.666 and 0.780, respectively). This initial study suggests that significant discrepancy of breast lesion measurement between conventional US and CEUS is more likely presented in breast cancer than benign lesions. The pathologic findings corresponding to the region of size increased at CEUS are malignant in most malignant

  16. Assessing terpene content variability of whitebark pine in order to estimate representative sample size

    Directory of Open Access Journals (Sweden)

    Stefanović Milena

    2013-01-01

    Full Text Available In studies of population variability, particular attention has to be paid to the selection of a representative sample. The aim of this study was to assess the size of the new representative sample on the basis of the variability of chemical content of the initial sample on the example of a whitebark pine population. Statistical analysis included the content of 19 characteristics (terpene hydrocarbons and their derivates of the initial sample of 10 elements (trees. It was determined that the new sample should contain 20 trees so that the mean value calculated from it represents a basic set with a probability higher than 95 %. Determination of the lower limit of the representative sample size that guarantees a satisfactory reliability of generalization proved to be very important in order to achieve cost efficiency of the research. [Projekat Ministarstva nauke Republike Srbije, br. OI-173011, br. TR-37002 i br. III-43007

  17. New Atrophic Acne Scar Classification: Reliability of Assessments Based on Size, Shape, and Number.

    Science.gov (United States)

    Kang, Sewon; Lozada, Vicente Torres; Bettoli, Vincenzo; Tan, Jerry; Rueda, Maria Jose; Layton, Alison; Petit, Lauren; Dréno, Brigitte

    2016-06-01

    Post-acne atrophic scarring is a major concern for which standardized outcome measures are needed. Traditionally, this type of scar has been classified based on shape; but survey of practicing dermatologists has shown that atrophic scar morphology has not been well enough defined to allow good agreement in clinical classification. Reliance on clinical assessment is still needed at the current time, since objective tools are not yet available in routine practice. Evaluate classification for atrophic acne scars by shape, size, and facial location and establish reliability in assessments. We conducted a non-interventional study with dermatologists performing live clinical assessments of atrophic acne scars. To objectively compare identification of lesions, individual lesions were marked on a high-resolution photo of the patient that was displayed on a computer during the clinical evaluation. The Jacob clinical classification system was used to define three primary shapes of scars 1) icepick, 2) boxcar, and 3) rolling. To determine agreement for classification by size, independent technicians assessed the investigators' markings on digital images. Identical localization of scars was denoted if the maximal distance between their centers was ≤ 60 pixels (approximately 3 mm). Raters assessed scars on the same patients twice (morning/afternoon). Aggregate models of rater assessments were created and analyzed for agreement. Raters counted a mean scar count per subject ranging from 15.75 to 40.25 scars. Approximately 50% of scars were identified by all raters and ~75% of scars were identified by at least 2 of 3 raters (weak agreement, Kappa pairwise agreement 0.30). Agreement between consecutive counts was moderate, with Kappa index ranging from 0.26 to 0.47 (after exclusion of one outlier investigator who had significantly higher counts than all others). Shape classifications of icepick, boxcar, and rolling differed significantly between raters and even for same raters at

  18. Quantitation of global and regional left ventricular function by MRI

    NARCIS (Netherlands)

    van der Geest, RJ; Reiber, JHC; Reiber, JHC; VanDerWall, EE

    1998-01-01

    Magnetic resonance imaging (MRI) provides several imaging strategies for assessing left ventricular function. As a three-dimensional imaging technique, all measurements can be performed without relying on geometrical assumptions. Global and regional function parameters can be derived from

  19. Final infarct size measured by cardiovascular magnetic resonance in patients with ST elevation myocardial infarction predicts long-term clinical outcome

    DEFF Research Database (Denmark)

    Lønborg, Jacob Thomsen; Vejlstrup, Niels Grove; Kelbæk, Henning Skov

    2013-01-01

    AIMS: Tailored heart failure treatment and risk assessment in patients following ST-segment elevation myocardial infarction (STEMI) is mainly based on the assessment of the left ventricular (LV) ejection fraction (EF). Assessment of the final infarct size in addition to the LVEF may improve...

  20. Preclinical safety assessments of nano-sized constructs on cardiovascular system toxicity: A case for telemetry.

    Science.gov (United States)

    Cheah, Hoay Yan; Kiew, Lik Voon; Lee, Hong Boon; Japundžić-Žigon, Nina; Vicent, Marίa J; Hoe, See Ziau; Chung, Lip Yong

    2017-11-01

    While nano-sized construct (NSC) use in medicine has grown significantly in recent years, reported unwanted side effects have raised safety concerns. However, the toxicity of NSCs to the cardiovascular system (CVS) and the relative merits of the associated evaluation methods have not been thoroughly studied. This review discusses the toxicological profiles of selected NSCs and provides an overview of the assessment methods, including in silico, in vitro, ex vivo and in vivo models and how they are related to CVS toxicity. We conclude the review by outlining the merits of telemetry coupled with spectral analysis, baroreceptor reflex sensitivity analysis and echocardiography as an appropriate integrated strategy for the assessment of the acute and chronic impact of NSCs on the CVS. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  1. Critical defect size assessment in pipelines on a nuclear power plant

    Directory of Open Access Journals (Sweden)

    Dimova Galya

    2018-01-01

    Full Text Available In many energy industry structures, pipeline systems are subject to the impact of mechanical forces, moments of forces and fluid flows of high pressure and temperature. These load factors cause defects in the pipeline metal. As the years of operation increase, defects may occur and grow, which may lead to the destruction of pipeline walls. Special measures have been planned and implemented to ensure the safe operation of high-energy facilities. This study focused on pipelines and nozzles of nuclear power plant equipment with bimetal welded joints on which the size of critical defects was assessed. The base of assessment covers material properties, temperature and stress fields, fracture mechanics calculations. This study involves developing of finite element models and implementing simulations on them in order to obtain temperature fields and determine the stress-strain state of the component.

  2. Assessing cancer drugs for reimbursement: methodology, relationship between effect size and medical need.

    Science.gov (United States)

    de Sahb-Berkovitch, Rima; Woronoff-Lemsi, Marie-Christine; Molimard, Mathieu

    2010-01-01

    Reimbursement is assessed by the Transparency Commission from the Health Authority (HAS) using a medical benefit (SMR) score that gives access to reimbursement, an "improvement of medical service rendered" (ASMR) that determines the added therapeutic value, and the target population. Assessing cancer drugs for reimbursement raises the same issues as other therapeutic classes, with some key differences. Overall survival (OS) is considered by the Transparency Commission as the endpoint for assessing clinical benefit, and yet it is not an applicable primary endpoint in all types of cancer. Later lines of treatment, particularly during the development process, may make it difficult to interpret OS as the primary endpoint. Therefore, progression-free survival (PFS) for metastatic situations and disease-free survival (DFS) in adjuvant situations are wholly relevant endpoints for decisions on the reimbursement of a new cancer drug. Effect size is assessed using actuarial survival curves of the product versus the comparator, and it is difficult to summarise them into one single parameter. Results are generally interpreted based on median survival, which is fragmented because it only measures one point of the curve. The hazard ratio measures the effect of treatment throughout the duration of survival and is therefore more comprehensive in quantifying clinical benefit. Determining an effect size threshold for granting reimbursement is difficult given the diversity of cancer settings and the level of medical need, which influences assessment of the clinical relevance of the observed difference. Rapid progress in comparators (700 molecules in development) and the identification of predictive factors of efficacy (biomarkers, histology, etc.) during development may lead to different ASMR scores per population, or to the restriction of the target population to a subgroup of the marketing authorisation (MA) population in which the expected effect size is greater. To address these

  3. Assessment of crown angulations, crown inclinations, and tooth size discrepancies in a South Indian population

    Directory of Open Access Journals (Sweden)

    Geeta Maruti Doodamani

    2011-01-01

    Full Text Available Aims and Objective: The aim of this study was to assess crown angulations, crown inclinations, and tooth size discrepancy in a sample population from Davangere, South India. Materials and Methods: One hundred adults (50 male and 50 female of age 18-30 years, with Angle′s class I ideal occlusion and balanced profiles, were selected for the study. Study models were prepared and crown angulations and crown inclinations were measured using a customized protractor device. Bolton′s analysis was used to measure the tooth size discrepancies. Results: Maxillary and mandibular teeth had less crown angulations. Maxillary and mandibular incisors and maxillary molars showed increased crown inclinations, whereas mandibular molars and premolars had less crown inclinations than the original Andrews sample. The mean maxillary and mandibular tooth size ratios, overall and anterior, were similar to Bolton′s ratios. Conclusions: The finding of this study indicates that there are possible racial and ethnic factors contributing to variations in crown angulations and crown inclinations.

  4. Predictors of the left ventricular dysfunction induced by ventricular arrhythmia

    Directory of Open Access Journals (Sweden)

    А. І. Vytryhovskiy

    2016-08-01

    Full Text Available The most powerful predictor of life-threatening arrhythmia risk is a combination of low heart rate variability with low ejection fraction (EF of the left ventricle. Aim. To identify predictors of left ventricle dysfunction which is induced by ventricular arrhythmia. Materials and methods. To diagnose structural changes of left ventricular functional capacity and reserves in patients with previous myocardial infarction and patients with high and very high cardiovascular risk by SCORE scale and for establishment the relationship between morphological heart changes and pathological phenomenon of heart turbulence echocardiography and study of heart rate turbulence variability were performed. 603 patients were selected for the research. All patients were divided into groups: group 1 – patients with coronary heart disease, but without associated risk factors, such as smoking, obesity, metabolic syndrome; group 2 – patients who smoke tobacco more than 2 years (very high cardiovascular risk by scale SCORE; group 3 – patients with metabolic syndrome without coronary heart disease or arterial hypertension (very high cardiovascular risk by scale SCORE. The control group consisted of 149 persons. Results. The feature of structural changes in patients with myocardial infarction and in patients with a high cardiovascular risk by SCORE with heart rate turbulence compared with cases without НRT is considerably thickening of the left interventricular septum in systole. Based on this, it can be argued that the emergence of ventricular arrhythmia and accordingly phenomenon of heart rate turbulence in patients with existing cardiovascular diseases and risk factors has both morphological and functional character. Significant difference of echocardioscopy parameters in patients with postinfarction cardiosclerosis and risk factors by the SCORE system was established by index of intraventricular septum thickness in systole, and in persons with high risk – in

  5. Left Ventricular Hypertrophy in Children with Hypertension: in Search of a Definition.

    Science.gov (United States)

    Sethna, Christine B; Leisman, Daniel E

    2016-08-01

    The purpose of this review is to provide background on the importance of left ventricular hypertrophy (LVH) in children with hypertension, to highlight various diagnostic modalities and measures for defining LVH, and to demonstrate the need for standardization and a consensus definition for LVH in the pediatric population. There is no clear consensus among specialists performing echocardiograms and treating clinicians on the definition of LVH in children with hypertension. In fact, there is considerable variation in every step of the evaluation of pediatric LVH. There is variation in every step of the assessment of LVH in the pediatric population. This variation exists in imaging modality, the type of measurement used, the method of calculating left ventricular mass (LVM), the method of indexing LVM to body size, the normalization method for the index used, the reference data used, the inclusion of confounders, the implementation in clinical practice, and the format for echocardiography reporting.

  6. Compressed sensing real-time cine cardiovascular magnetic resonance: accurate assessment of left ventricular function in a single-breath-hold.

    Science.gov (United States)

    Kido, Tomoyuki; Kido, Teruhito; Nakamura, Masashi; Watanabe, Kouki; Schmidt, Michaela; Forman, Christoph; Mochizuki, Teruhito

    2016-08-24

    Cardiovascular cine magnetic resonance (CMR) accelerated by compressed sensing (CS) is used to assess left ventricular (LV) function. However, it is difficult for prospective CS cine CMR to capture the complete end-diastolic phase, which can lead to underestimation of the end-diastolic volume (EDV), stroke volume (SV), and ejection fraction (EF), compared to retrospective standard cine CMR. This prospective study aimed to evaluate the diagnostic quality and accuracy of single-breath-hold full cardiac cycle CS cine CMR, acquired over two heart beats, to quantify LV volume in comparison to multi-breath-hold standard cine CMR. Eighty-one participants underwent standard segmented breath-hold cine and CS real-time cine CMR examinations to obtain a stack of eight contiguous short-axis images with same high spatial (1.7 × 1.7 mm(2)) and temporal resolution (41 ms). Two radiologists independently performed qualitative analysis of image quality (score, 1 [i.e., "nondiagnostic"] to 5 [i.e., "excellent"]) and quantitative analysis of the LV volume measurements. The total examination time was 113 ± 7 s for standard cine CMR and 24 ± 4 s for CS cine CMR (p cine image quality was slightly lower than standard cine (4.8 ± 0.5 for standard vs. 4.4 ± 0.5 for CS; p cine were above 4 (i.e., good). No significant differences existed between standard and CS cine MR for all quantitative LV measurements. The mean differences with 95 % confidence interval (CI), based on Bland-Altman analysis, were 1.3 mL (95 % CI, -14.6 - 17.2) for LV end-diastolic volume, 0.2 mL (95 % CI, -9.8 to10.3) for LV end-systolic volume, 1.1 mL (95 % CI, -10.5 to 12.7) for LV stroke volume, 1.0 g (95 % CI, -11.2 to 13.3) for LV mass, and 0.4 % (95 % CI, -4.8 - 5.6) for LV ejection fraction. The interobserver and intraobserver variability for CS cine MR ranged from -4.8 - 1.6 % and from -7.3 - 9.3 %, respectively, with slopes of the regressions ranging 0.88-1.0 and 0

  7. Detection of impaired fatty acid metabolism in right ventricular hypertrophy. Assessment by I-123 {beta}-methyl iodophenyl pentadecanoic acid (BMIPP) myocardial single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong-ih; Goto, Hideki; Kobayashi, Katsuhiro; Sawada, Yoshihiro; Miyake, Yoshitaka; Fujiwara, Go [Nishiyodo Hospital, Osaka (Japan); Chiba, Hiroshi; Okada, Tomoya; Nishimura, Tsunehiko

    1997-08-01

    The subjects consisted of 6 patients with chronic obstructive pulmonary disease, 4 with primary pulmonary hypertension, 2 each with refractory pulmonary tuberculosis, tricuspid insufficiency, pulmonary embolism, 1 each with atrial septal defect, ventricular septal defect (Eisenmenger complex), Ebstein anomaly, and endocardial defect, and 7 healthy controls. SPECT imaging with Tl-201 (Tl) and I-123 BMIPP, and Tc-99m RBC first pass and gated blood pool scintigraphy were performed. Based on Tl planar images, the subjects were classified into 3 groups: 7 patients with no RV visualization (Group A), 11 with moderate RV visualization (Group B) and 9 with marked RV visualization (Group C). As a semi-quantitative evaluation by a myocardial SPECT, 3 regions in 3 representative short axial images were divided into 9 segments, each of which was graded from 0 to +3, and their sum was calculated as the RV score. The right ventricular ejection fraction (RVEF) and the left ventricular ejection fraction were obtained by Tc-99m RBC cardiac scintigraphy. The groups with marked visualization of the right ventricle had lower RVEF, and there was a good correlation between the RVEF and the RV score with both a and BMIPP. Although a good correlation was demonstrated between the RV score with Tl and BMIPP in Groups A and B, in Group C, in which there was marked RV Tl visualization, the RV score with BMIPP was significantly smaller than with Tl. These findings suggest that impaired fatty acid metabolism may exist in severely hypertrophic right ventricle due to RV overload. (K.H.)

  8. Detection of impaired fatty acid metabolism in right ventricular hypertrophy. Assessment by I-123 β-methyl iodophenyl pentadecanoic acid (BMIPP) myocardial single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Kim, Yong-ih; Goto, Hideki; Kobayashi, Katsuhiro; Sawada, Yoshihiro; Miyake, Yoshitaka; Fujiwara, Go; Chiba, Hiroshi; Okada, Tomoya; Nishimura, Tsunehiko.

    1997-01-01

    The subjects consisted of 6 patients with chronic obstructive pulmonary disease, 4 with primary pulmonary hypertension, 2 each with refractory pulmonary tuberculosis, tricuspid insufficiency, pulmonary embolism, 1 each with atrial septal defect, ventricular septal defect (Eisenmenger complex), Ebstein anomaly, and endocardial defect, and 7 healthy controls. SPECT imaging with Tl-201 (Tl) and I-123 BMIPP, and Tc-99m RBC first pass and gated blood pool scintigraphy were performed. Based on Tl planar images, the subjects were classified into 3 groups: 7 patients with no RV visualization (Group A), 11 with moderate RV visualization (Group B) and 9 with marked RV visualization (Group C). As a semi-quantitative evaluation by a myocardial SPECT, 3 regions in 3 representative short axial images were divided into 9 segments, each of which was graded from 0 to +3, and their sum was calculated as the RV score. The right ventricular ejection fraction (RVEF and the left ventricular ejection fraction were obtained by Tc-99m RBC cardiac scintigraphy. The groups with marked visualization of the right ventricle had lower RVEF, and there was a good correlation between the RVEF and the RV score with both a and BMIPP. Although a good correlation was demonstrated between the RV score with Tl and BMIPP in Groups A and B, in Group C, in which there was marked RV Tl visualization, the RV score with BMIPP was significantly smaller than with Tl. These findings suggest that impaired fatty acid metabolism may exist in severely hypertrophic right ventricle due to RV overload. (K.H.)

  9. Right ventricular ejection fraction during exercise in normal subjects and in coronary artery disease patients: assessment by multiple-gated equilibrium scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Maddahi, J.; Berman, D.S.; Matsuoka, D.T.; Waxman, A.D.; Forrester, J.S.; Swan, H.J.C.

    1980-07-01

    The response of right ventricular ejection fraction (RVEF) during exercise and its relationship to the location and extent of coronary artery disease are not fully understood. We have recently developed and validated a new method for scintigraphic evaluation of RVEF using rapid multiple-gated equilibrium scintigraphy and multiple right ventricular regions of interest. The technique has been applied during upright bicycle exercise in 10 normal subjects and 20 patients with coronary artery disease. Resting RVEF was not significantly different between the groups (0.49 +- 0.04 vs 0.47 +- 0.09, respectively, mean +- SD). In all 10 normal subjects RVEF rose (0.49 +- 0.04 to 0.66 +- 0.08, p < 0.01) at peak exercise. At peak exercise in coronary artery disease patients, the group RVEF remained unchanged (0.47 +- 0.09 to 0.50 +- 0.11, p = NS), but the individual responses varied. In the coronary artery disease patients, the relationship between RVEF response to exercise and exercise left ventricular function, septal motion and right coronary artery stenosis were studied. Significant statistical association was found only between exercise RVEF and right coronary artery stenosis. RVEF rose during exercise in seven of seven patients without right coronary artery stenosis (0.42 +- 0.06 to 0.58 +- 0.08, p = 0.001) and was unchanged or fell in 12 of 13 patients with right coronary artery stenosis (0.50 +- 0.09 to 0.45 +- 0.10, p = NS). We conclude that (1) in normal subjects RVEF increases during upright exercise and (2) although RVEF at rest is not necessarily affected by coronary artery disease, failure of RVEF to increase during exercise, in the absence of chronic obstructive pulmonary disease or valvular heart disease, may be related to the presence of significant right coronary artery stenosis.

  10. Right ventricular ejection fraction during exercise in normal subjects and in coronary artery disease patients: assessment by multiple-gated equilibrium scintigraphy

    International Nuclear Information System (INIS)

    Maddahi, J.; Berman, D.S.; Matsuoka, D.T.; Waxman, A.D.; Forrester, J.S.; Swan, H.J.C.

    1980-01-01

    The response of right ventricular ejection fraction (RVEF) during exercise and its relationship to the location and extent of coronary artery disease are not fully understood. We have recently developed and validated a new method for scintigraphic evaluation of RVEF using rapid multiple-gated equilibrium scintigraphy and multiple right ventricular regions of interest. The technique has been applied during upright bicycle exercise in 10 normal subjects and 20 patients with coronary artery disease. Resting RVEF was not significantly different between the groups (0.49 +- 0.04 vs 0.47 +- 0.09, respectively, mean +- SD). In all 10 normal subjects RVEF rose (0.49 +- 0.04 to 0.66 +- 0.08, p < 0.01) at peak exercise. At peak exercise in coronary artery disease patients, the group RVEF remained unchanged (0.47 +- 0.09 to 0.50 +- 0.11, p = NS), but the individual responses varied. In the coronary artery disease patients, the relationship between RVEF response to exercise and exercise left ventricular function, septal motion and right coronary artery stenosis were studied. Significant statistical association was found only between exercise RVEF and right coronary artery stenosis. RVEF rose during exercise in seven of seven patients without right coronary artery stenosis (0.42 +- 0.06 to 0.58 +- 0.08, p = 0.001) and was unchanged or fell in 12 of 13 patients with right coronary artery stenosis (0.50 +- 0.09 to 0.45 +- 0.10, p = NS). We conclude that (1) in normal subjects RVEF increases during upright exercise and (2) although RVEF at rest is not necessarily affected by coronary artery disease, failure of RVEF to increase during exercise, in the absence of chronic obstructive pulmonary disease or valvular heart disease, may be related to the presence of significant right coronary artery stenosis

  11. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    International Nuclear Information System (INIS)

    Christianson, Olav; Li Xiang; Frush, Donald; Samei, Ehsan

    2012-01-01

    Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED adj ). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED adj between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED adj that differed by up to 44% from effective dose estimates that were not

  12. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    Energy Technology Data Exchange (ETDEWEB)

    Christianson, Olav; Li Xiang; Frush, Donald; Samei, Ehsan [Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 and Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States) and Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Department of Physics, Duke University, Durham, North Carolina 27710 (United States); and Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States)

    2012-11-15

    Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED{sub adj}). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED{sub adj} between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED{sub adj} that differed by up to 44% from effective dose

  13. LEFT VENTRICULAR ROTATION, TWIST AND UNTWIST: PHYSIOLOGICAL ROLE AND CLINICAL RELEVANCE

    Directory of Open Access Journals (Sweden)

    E. N. Pavlyukova

    2015-09-01

    Full Text Available The helical ventricular myocardial band of Torrent-Guasp is a new concept, which provides strong grounds for reconciliation of some important aspects in cardiovascular medicine. Oblique fiber orientation provides left ventricular rotation, which in addition to radial thickening and longitudinal shortening, is predicted as an essential component of the effective left ventricular pumping. Left ventricular rotation can be measured in clinical practice noninvasively using echocardiography and this provides new opportunities for the assessment of different aspects of left ventricular mechanical function.

  14. Ventricular Repolarization Evaluation From Surface ECG for Identification of the Patients With Increased Myocardial Electrical Instability

    National Research Council Canada - National Science Library

    Lass, Jaanus

    2001-01-01

    In order to reveal the possible correlation between the level of myocardial electrical instability assessed at Holter monitoring and certain ECG parameters characterizing ventricular repolarization...

  15. Comparison of regional versus global assessment of left ventricular function in patients with left ventricular dysfunction, heart failure, or both after myocardial infarction: the valsartan in acute myocardial infarction echocardiographic study

    DEFF Research Database (Denmark)

    Thune, Jens Jakob; Køber, Lars; Pfeffer, Marc A

    2006-01-01

    or complementary information about prognosis after MI. METHODS: Echocardiography was performed in 610 patients with LV dysfunction, heart failure, or both after MI enrolled in the Valsartan in Acute MI trial. LVEF was estimated by biplane Simpson's rule, and WMI was assessed using a 16-segment model in 502...

  16. MRI of the Breast for the Detection and Assessment of the Size of Ductal Carcinoma in Situ

    International Nuclear Information System (INIS)

    Kim, Do Youn; Moon, Woo Kyung; Cho, Nariya

    2007-01-01

    The aim of the study was to compare the accuracy of magnetic resonance imaging (MRI) and mammography for the detection and assessment of the size of ductal carcinoma in situ (DCIS). The preoperative contrast-enhanced MRI and mammography were analyzed in respect of the detection and assessment of the size of DCIS in 72 patients (age range: 30 67 years, mean age: 47 years). The MRI and mammographic measurements were compared with the histopathologic size with using the Pearson's correlation coefficients and the Mann-Whitney u test. We evaluated whether the breast density, the tumor nuclear grade, the presence of comedo necrosis and microinvasion influenced the MRI and mammographic size estimates by using the chi-square test. Of the 72 DCIS lesions, 68 (94%) were detected by MRI and 62 (86%) were detected by mammography. Overall, the Pearson's correlation of the size between MRI and histopathology was 0.786 versus 0.633 between mammography and histopathology (p < 0.001). MRI underestimated the size by more than 1 cm (including false negative examination) in 12 patients (17%), was accurate in 52 patients (72%) and overestimated the size by more than 1 cm in eight patients (11%) whereas mammography underestimated the size in 25 patients (35%), was accurate in 31 patients (43%) and overestimated the size in 16 patients (22%). The MRI, but not the mammography, showed significant correlation for the assessment of the size of tumor in noncomedo DCIS (p < 0.001 vs p = 0.060). The assessment of tumor size by MRI was affected by the nuclear grade (p = 0.008) and the presence of comedo necrosis (p = 0.029), but not by the breast density (p 0.747) or microinvasion (p = 0.093). MRI was more accurate for the detection and assessment of the size of DCIS than mammography

  17. Evaluation of ventricular function in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Rocco, T.P.; Dilsizian, V.; Fischman, A.J.; Strauss, H.W.

    1989-01-01

    The recent expansion of interventional cardiovascular technologies has stimulated a concomitant expansion of noninvasive cardiac studies, both to assist in diagnosis and to evaluate treatment outcomes. Radionuclide ventricular function studies provide a reliable, reproducible means to quantify global left ventricular systolic performance, a critical determinant of prognosis in patients with cardiovascular disease. In addition, the ability to evaluate regional left ventricular wall motion and to assess ventricular performance during exercise have secured a fundamental role for such studies in the screening and treatment of patients with coronary artery disease. Radionuclide techniques have been extended to the evaluation of left ventricular relaxation/filling events, left ventricular systolic/diastolic function in the ambulatory setting, and with appropriate technical modifications, to the assessment of right ventricular performance at rest and with exercise. As a complement to radionuclide perfusion studies, cardiac blood-pool imaging allows for thorough noninvasive description of cardiac physiology and function in both normal subjects and in patients with a broad range of cardiovascular diseases. 122 references

  18. Beat-to-beat ECG restitution: A review and proposal for a new biomarker to assess cardiac stress and ventricular tachyarrhythmia vulnerability.

    Science.gov (United States)

    Fossa, Anthony A

    2017-09-01

    Cardiac restitution is the ability of the heart to recover from one beat to the next. Ventricular arrhythmia vulnerability can occur when the heart does not properly adjust to sudden changes in rate or in hemodynamics leading to excessive temporal and/or spatial heterogeneity in conduction or repolarization. Restitution has historically been used to study, by invasive means, the dynamics of the relationship between action potential duration (APD) and diastolic interval (DI) in sedated subjects using various pacing protocols. Even though the analogous measures of APD and DI can be obtained using the surface ECG to acquire the respective QT and TQ intervals for ECG restitution, this methodology has not been widely adopted for a number of reasons. Recent development of more advanced software algorithms enables ECG intervals to be measured accurately, on a continuous beat-to-beat basis, in an automated manner, and under highly dynamic conditions (i.e., ambulatory or exercise) providing information beyond that available in the typical resting state. Current breakthroughs in ECG technology will allow ECG restitution measures to become a practical approach for providing quantitative measures of the risks for ventricular arrhythmias as well as cardiac stress in general. In addition to a review of the underlying principles and caveats of ECG restitution, a new approach toward an advancement of more integrated restitution biomarkers is proposed. © 2017 Wiley Periodicals, Inc.

  19. Effect of right ventricular electrode location (outflow tract vs. apex) on mechanical Ventricular synchrony in patients that underwent pacemaker implant therapy

    International Nuclear Information System (INIS)

    Rincon, Oscar S; Saenz, Luis C; Salazar, Gabriel; Hernandez, Edgar

    2008-01-01

    Objective: to assess in depth the effect of ventricular stimulation from the right ventricular outflow tract and the apex on mechanical ventricular synchrony. Materials And Methods: cohort analytical study. 20 patients with indication of definitive pacemaker indication underwent trans thoracic echocardiogram before and after pacemaker implant with electrode implantation in the right ventricular outflow tract and in the apex (10 patients in each group). There was no structural cardiopathy, ejection fraction was ? 50%, QRS and AV conduction were normal. Mechanical ventricular asynchrony (M mode and tissue doppler) and implant and device parameters were evaluated. Statistical Analysis: results are given as mean values, standard deviation or percentages.Continuous variables were compared using Chi-square test and ANOVA. A p <0.05 value was considered statistically significant. Results: in five patients (25%) a pre-implant ventricular asynchrony was found; in seven (70%) ventricular asynchrony post-implant in the right ventricle outflow tract and in 5 (50%) in the apex. Mean interventricular pot-implant delay was 21,6 ms in the right ventricular outflow tract and 11,5 ms in the apex (p = 0,8); mean septal to lateral wall delay was 73 ms in the right ventricular outflow tract and 26 ms in the apex (p = 0,8). QRS post-implant delay was 134 ms in the right ventricular outflow tract and 140 ms in the apex (p = 0,1). No differences between implant parameters and device programming were found. Conclusions: presence of ventricular asynchrony was evidenced in patients with normal QRS and structurally healthy heart. Ventricular stimulation with pacemaker from the apex or the right ventricular outflow tract suggests acute ventricular asynchrony at least in 60% of the cases, without statistically significant difference between both groups.

  20. Assessment of right ventricular adaptability to loading conditions can improve the timing of listing to transplantation in patients with pulmonary arterial hypertension.

    Science.gov (United States)

    Dandel, Michael; Knosalla, Christoph; Kemper, Dagmar; Stein, Julia; Hetzer, Roland

    2015-03-01

    Right ventricle (RV) performance is load dependent, and right-sided heart failure (RHF) is the main cause of death in pulmonary arterial hypertension (PAH). Prediction of RV worsening for timely identification of patients needing transplantation (Tx) is paramount. Assessment of RV adaptability to load has proved useful in certain clinical circumstances. This study assessed its predictive value for RHF-free and Tx-free outcome with PAH. Between 2006 and 2012, all potential Tx candidates with PAH, without RHF at the first evaluation, were selected for follow-up (except congenital heart diseases). At selection and at each follow-up, N-terminal prohormone brain natriuretic peptide (NT-proBNP) and the 6-minute walk distance were measured, and RV adaptability to load was assessed by echocardiography. Collected data were tested for the ability to predict RV stability and Tx-free survival. During a 12-month to 92-month follow-up, RHF developed in 23 of 79 evaluated patients, despite similar medication and no differences in initial RV size and ejection fraction compared with the patients who remained stable. However, unstable patients had an initially lower RV load-adaptation index and afterload-corrected peak global systolic longitudinal strain-rate values as well as higher RV dyssynchrony, tricuspid regurgitation, and NT-proBNP levels (p ≤ 0.01). At certain cutoff values, these variables appeared predictive for 1-year and 3-year freedom from RHF and 3-year Tx-free survival. An RV load-adaptation index reduction of ≥20% showed the highest predictive value (90.0%) for short-term (≤1 year) RV decompensation. Assessment of RV adaptability to load allows prediction of RV function and Tx-free survival with severe PAH during the next 1 to 3 years. This can improve the timing of listing for Tx. Copyright © 2015 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  1. Radionuclide assessment of left ventricular diastolic function in patients with mitral stenosis before and after percutaneous transvenous mitral commissurotomy; Use of list mode method in patients with atrial fibrillation

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Seishi; Iwasaka, Toshiji; Kimura, Yutaka; Ohkubo, Naohiko; Matsuura, Takashi; Inada, Mitsuo; Shiraishi, Tomokuni [Kansai Medical School, Moriguchi, Osaka (Japan)

    1991-07-01

    To evaluate the effect of percutaneous transvenous mitral commissurotomy (PTMC), equilibrium radionuclide angiocardiography was performed in eight patients with mitral stenosis who had atrial fibrillation. Accurate cardiac function in patients with atrial fibrillation is difficult to assess, since the wide fluctation of cardiac cycle makes the ventricular hemodynamics variable. A new processing algorhythm was devised to make multiple gated images discriminated from a heart rate distribution histogram. We obtained about 1,000 beats data by list mode acquisition, and processed a heart rate distribution histogram. The data in the area {+-}5% of the most frequent heart rate were converted into frame mode and a representative time activity curve was derived. Mitral valve area calculated by echocardiography increased from 1.3{+-}0.5 to 2.0{+-}0.6 (cm{sup 2}) significantly (p<0.01). The mean transmitral pressure gradient measured by catheterization decreased from 12.4{+-}5.9 to 4.9{+-}3.7 (mmHg) significantly (p<0.01) and the clinical symptoms improved in all patients. The change in left ventricular ejection fraction from 43{+-}9 to 48{+-}13 (%) was not statistically significant, but peak filling rate (PFR) derived from the time activity curve increased from 1.5{+-}0.3 to 2.0{+-}0.4 (EDV/sec) significantly (p<0.01). Thus PFR is a noninvasive parameter that can evaluate the effect of PTMC. (author).

  2. Systolic left ventricular function according to left ventricular concentricity and dilatation in hypertensive patients

    DEFF Research Database (Denmark)

    Bang, Casper; Gerdts, Eva; Aurigemma, Gerard P

    2013-01-01

    Left ventricular hypertrophy [LVH, high left ventricular mass (LVM)] is traditionally classified as concentric or eccentric based on left ventricular relative wall thickness. We evaluated left ventricular systolic function in a new four-group LVH classification based on left ventricular dilatation...... [high left ventricular end-diastolic volume (EDV) index and concentricity (LVM/EDV)] in hypertensive patients....

  3. Assessing T cell clonal size distribution: a non-parametric approach.

    Directory of Open Access Journals (Sweden)

    Olesya V Bolkhovskaya

    Full Text Available Clonal structure of the human peripheral T-cell repertoire is shaped by a number of homeostatic mechanisms, including antigen presentation, cytokine and cell regulation. Its accurate tuning leads to a remarkable ability to combat pathogens in all their variety, while systemic failures may lead to severe consequences like autoimmune diseases. Here we develop and make use of a non-parametric statistical approach to assess T cell clonal size distributions from recent next generation sequencing data. For 41 healthy individuals and a patient with ankylosing spondylitis, who undergone treatment, we invariably find power law scaling over several decades and for the first time calculate quantitatively meaningful values of decay exponent. It has proved to be much the same among healthy donors, significantly different for an autoimmune patient before the therapy, and converging towards a typical value afterwards. We discuss implications of the findings for theoretical understanding and mathematical modeling of adaptive immunity.

  4. Assessing T cell clonal size distribution: a non-parametric approach.

    Science.gov (United States)

    Bolkhovskaya, Olesya V; Zorin, Daniil Yu; Ivanchenko, Mikhail V

    2014-01-01

    Clonal structure of the human peripheral T-cell repertoire is shaped by a number of homeostatic mechanisms, including antigen presentation, cytokine and cell regulation. Its accurate tuning leads to a remarkable ability to combat pathogens in all their variety, while systemic failures may lead to severe consequences like autoimmune diseases. Here we develop and make use of a non-parametric statistical approach to assess T cell clonal size distributions from recent next generation sequencing data. For 41 healthy individuals and a patient with ankylosing spondylitis, who undergone treatment, we invariably find power law scaling over several decades and for the first time calculate quantitatively meaningful values of decay exponent. It has proved to be much the same among healthy donors, significantly different for an autoimmune patient before the therapy, and converging towards a typical value afterwards. We discuss implications of the findings for theoretical understanding and mathematical modeling of adaptive immunity.

  5. Determination of Matrix Pore Size Distribution in Fractured Clayey Till and Assessment of Matrix Migration of Dechlorinationg Bacteria

    DEFF Research Database (Denmark)

    Cong, Lu; Broholm, Mette Martina; Fabricius, Ida Lykke

    2014-01-01

    The pore structure and pore size distribution (PSD) in the clayey till matrix from three Danish field sites were investigated by image analysis to assess the matrix migration of dechlorinating bacteria in clayey till. Clayey till samples had a wide range of pore sizes, with diameters of 0.1–100 μ...

  6. Assessing market competition and vendors' size and scope on AlphaBay.

    Science.gov (United States)

    Paquet-Clouston, Masarah; Décary-Hétu, David; Morselli, Carlo

    2018-04-01

    Since 2011, drug market participants have traded illegal drugs through cryptomarkets, a user-friendly infrastructure in which drug market participants can conduct business transactions. This study assesses market competition and the size and scope of drug vendors' activities on one of the largest cryptomarkets, AlphaBay, in order to better understand the challenges that drug vendors face when selling on this venue. Relying on data collected from AlphaBay, we calculate the degree of competition within the drug market using the Herfindhal-Hirshmann Index (HHI). We then follow a micro analytical approach and assess the size and scope of vendors' accounts. This is done by evaluating each vendor's market share over time using a group-based trajectory model (GBTM). Results from the GBTM are then used to assess vendors' exposure, diversity and experience based on their selling position in the market. The HHI scores demonstrate that cryptomarkets offer a highly competitive environment that fits in a top-heavy market structure. However, the distribution of vendors' market share trajectories shows that only a small portion of vendors (referred to as high-level vendors) succeed in generating regular sales, whereas the majority of vendors are relegated to being mere market spectators with almost zero sales. This inequality is exacerbated by the aggressive advertising of high-level vendors who post many listings. Overall, product diversity and experience is limited for all market participants regardless of their level of success. We interpret these results through Reuter's work on traditional illegal markets, e-commerce studies and the growing field of cryptomarket research. We conclude that, while offering a new venue for illegal drug transactions, in many ways, the economics of cryptomarkets for drug dealing are consistent with Reuter's classic assessment of illegal markets and the consequences of product illegality that underlie it. Cryptomarkets conflicting features, a

  7. A case of short-coupled premature ventricular beat-induced ventricular fibrillation with early repolarization in the inferolateral leads

    Directory of Open Access Journals (Sweden)

    Hidekazu Kondo, MD

    2015-02-01

    Full Text Available This case report describes a 19-year-old man with early repolarization (ER in the inferolateral leads and a normal QT interval who survived a cardiac arrest that was likely related to polymorphic ventricular tachycardia (VT. Electrocardiograms (ECGs also showed unifocal premature ventricular beats (PVBs with a relatively narrow QRS duration. A Holter ECG documented occasional short-coupled PVBs following non-sustained VTs. Pharmacological stress testing was also performed to assess the effects of anti-arrhythmic drugs on ER (the J wave and PVBs. We performed successful radiofrequency catheter ablation to prevent the recurrence of ventricular fibrillation after cardioverter-defibrillator implantation.

  8. Left Ventricular Function after Arterial Switch Operation as Assessed by Two-Dimensional Speckle-Tracking Echocardiography in Patients with Simple Transposition of the Great Arteries.

    Science.gov (United States)

    Malakan Rad, Elaheh; Ghandi, Yazdan; Kocharian, Armen; Mirzaaghayan, Mohammadreza

    2016-07-06

    Background: The late postoperative course for children with transposition of the great arteries (TGA) with an intact ventricular septum (IVS) is very important because the coronary arteries may be at risk of damage during arterial switch operation (ASO). We sought to investigate left ventricular function in patients with TGA/IVS by echocardiography. Methods: From March 2011 to December 2012, totally 20 infants (12 males and 8 females) with TGA/IVS were evaluated via 2-dimensional speckle-tracking echocardiography (2D STE) more than 6 months after they underwent ASO. A control group of age-matched infants and children was also studied. Left ventricular longitudinal strain (S), strain rate (SR), time to peak systolic longitudinal strain (TPS), and time to peak systolic longitudinal strain rate (TPSR) were measured and compared between the 2 groups. Results: Mean ± SD of age at the time of study in the patients with TGA/IVS was 15 ± 5 months, and also age at the time of ASO was 12 ± 3 days. Weight was 3.13 ± 0.07 kg at birth and 8.83 ± 1.57 kg at the time of ASO. Global strain (S), Time to peak strain rate (TPSR), and Time to peak strain (TPS) were not significantly different between the 2 groups, whereas global strain rate (SR) was significantly different (p value < 0.001). In the 3-chamber view, the values of S in the lateral, septal, inferior, and anteroseptal walls were significantly different between the 2 groups (p value < 0.001), and SR in the posterior wall was significantly different between the 2 groups (p value < 0.001). There were no positive correlations between S and SR in terms of the variables of heart rate, total cardiopulmonary bypass time, and aortic cross-clamp time. There were no statistically significant differences between the 2 groups regarding S, SR, TPS, and TPSR in the anteroseptal and posterior walls in the 3-chamber view and in the lateral and septal walls in the 4-chamber view. Conclusion: We showed that between 6 and 18 months after

  9. Effect of beta-blockade on low-dose dobutamine-induced changes in left ventricular function in healthy volunteers: assessment by gated SPET myocardial perfusion scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Everaert, H.; Vanhove, C.; Franken, P.R. [Division of Nuclear Medicine, University Hospital, Free University of Brussels (AZ VUB), Brussels (Belgium)

    2000-04-01

    Viability studies are often performed in patients receiving beta-blocking agents. However, the intake of beta-blocking agents could influence the identification of viable myocardium when low-dose dobutamine is used to demonstrate inotropic reserve. The aim of this study was to quantify the effect of beta-blockade on global and regional left ventricular function in healthy volunteers using low-dose dobutamine gated single-photon emission tomographic (SPET) myocardial perfusion scintigraphy. Ten subjects were studied once ''on'' and once ''off'' beta-blocker therapy (metoprolol succinate, 100 mg day{sup -1}). On each occasion four consecutive gated SPET acquisitions (of 7 min duration) were recorded after injection of 925 MBq technetium-99m tetrofosmin on a triple-headed camera equipped with focussing (Cardiofocal) collimators. Acquisitions were made at rest (baseline 1 and 2) and 5 min after the beginning of the infusion of 5 and 10 {mu}g kg{sup -1} min{sup -1} dobutamine. Wall thickening (WT) was quantified using a method based on circumferential profile analysis. Left ventricular ejection fraction (LVEF) was obtained using the Cedars-Sinai algorithm. Blood pressure (BP) and heart rate (HR) were recorded at the end of each acquisition. At baseline LVEF, WT and systolic BP values under beta-blockade were not significantly different from those obtained in the non-beta-blocked state. The mean HR and diastolic BP at baseline were lower under beta-blockade. Dobutamine administration (at 5 and 10 {mu}g kg{sup -1} min{sup -1}) induced a significant increase in WT, LVEF and systolic BP in all subjects both on and off beta-blockade. The increases in WT, LVEF and systolic BP in the beta-blocked state were less pronounced but not significantly different. HR increased significantly at 10 {mu}g kg{sup -1} min{sup -1} dobutamine without beta-blocker administration, while no increase in HR was observed in the beta-blocked state. Beta

  10. Assessment of right ventricular overload using 99mTc-hexakis-methoxy-2-isobutylisonitrile (MIBI) and 123I-β-methyl iodophenyl pentadecanoic acid (BMIPP) myocardial scintigraphy

    International Nuclear Information System (INIS)

    Matsumoto, Katsushige

    2002-01-01

    Thallium-201 myocardial imaging is known to be useful for evaluating right ventricular (RV) overload. The degree of RV wall visualization has been shown to reflect RV myocardial mass and the right-to-left ventricular pressure ratio. Recently, 99m Tc-hexakis-methoxy-2-isobutylisonitrile (MIBI) and 123 I-β-methyl iodophenyl pentadecanoic acid (BMIPP) were developed and have been used to evaluate ischemic heart disease. The purpose of this study was to evaluate the RV pressure and myocardial fatty acid metabolism in the right ventricle in patients with chronic RV overloading using 99m Tc-MIBI and 123 I-BMIPP myocardial imaging. 99m Tc-MIBI myocardial scintigraphy (planar and SPECT) was performed in 76 patients with RV overloading, and 123 I-BMIPP SPECT was performed in 33 patients with RV overloading. The degree of RV wall visualization using 99m Tc-MIBI planar imaging was correlated with the elevation of RV systolic pressure. The right atrium was visualized with a high frequency in patients with RV overloading, and the degree of the right atrial wall visualization was correlated with the elevation of RV end-diastolic pressure. A count ratio of right-to-left ventricular free wall (RV/LV ratio) using 99m Tc-MIBI SPECT correlated well with a systolic pressure ratio of right-to-left ventricle (sRVp/sLVp). On the other hand, no significant correlation was found between RV/LV ratio using 123 I-BMIPP SPECT and sRVp/sLVp. For the patients with RV overloading at a RV systolic pressure of 70 mmHg or more, impaired fatty acid metabolism in the RV myocardium was noted using the quantitative analysis of 123 I-BMIPP SPECT. In conclusion, RV pressure can be evaluated by quantitative analysis using 99m Tc-MIBI myocardial scintigraphy. Myocardial metabolism in the RV wall may be impaired in patients with severe RV overloading. (author)

  11. ULTRASONOGRAPHIC ASSESSMENT OF NECK MUSCULAR SIZE AND RANGE OF MOTION IN RUGBY PLAYERS.

    Science.gov (United States)

    Hemelryck, Walter; Calistri, Josselin; Papadopoulou, Virginie; Theunissen, Sigrid; Dugardeyn, Christian; Balestra, Costantino

    2018-02-01

    World Rugby Union laws are constantly evolving towards stringent injury-prevention, particularly for contested scrums, since front row players are most at risk of cervical spine injuries. Recently, some countries have also introduced tailored training programs and minimum performance requirements for playing in the front row. Nevertheless, these approaches lack an objective assessment of each cervical muscle that would provide protective support. Since front row players are the most at risk for cervical spine injuries due to the specific type of contact during scrums, the purpose of this study was to ascertain whether significant differences exist in neck muscle size and range of motion between front row players and players of other positions, across playing categories. Cross-sectional controlled laboratory study. 129 sub-elite male subjects from various first-team squads of Belgian Rugby clubs were recruited. Subjects were grouped according to age: Junior (J)  35 years old; as well as playing position: Front row players (J = 10, S = 12, V = 11 subjects), (Rest of the) pack (J = 12, S = 12, V = 10), backs (J = 10, S = 11, V = 11). An age-matched control group of non-rugby players was also recruited (J = 10, S = 10, V = 10).For each subject, the total neck circumference (NC) and the cervical range of motion (CROM) were measured. In addition, the thickness of the trapezius (T), splenius capitis (SCa), semispinalis capitis (SCb), semispinalis cervicis (SPC), sternocleidomastoid muscles (SCOM), and the total thickness of all four structures (TT), were measured using ultrasonography. In each age category, compared to controls, rugby players were found to have decreased CROM, an increase in neck circumference (NC), and increased total thickness (TT), trapezius (T), semispinalis capitis (SCb) and sternocleidomastoid muscles (SCOM) sizes. For junior players, the thickness of the semispinalis cervicis (SPC) was also increased compared to controls. The CROM was decreased

  12. The role of business size in assessing the uptake of health promoting workplace initiatives in Australia

    Directory of Open Access Journals (Sweden)

    A. W. Taylor

    2016-04-01

    Full Text Available Abstract Background Worksite health promotion (WHP initiatives are increasingly seen as having potential for large-scale health gains. While health insurance premiums are directly linked to workplaces in the USA, other countries with universal health coverage, have less incentive to implement WHP programs. Size of the business is an important consideration with small worksites less likely to implement WHP programs. The aim of this study was to identify key intervention points and to provide policy makers with evidence for targeted interventions. Methods The worksites (n = 218 of randomly selected, working participants, aged between 30 and 65 years, in two South Australian cohort studies were surveyed to assess the practices, beliefs, and attitudes regarding WHP. A survey was sent electronically or by mail to management within each business. Results Smaller businesses (<20 employees had less current health promotion activies (mean 1.0 compared to medium size businesses (20–200 employees – mean 2.4 and large businesses (200+ employees – mean 2.9. Management in small businesses were less likely (31.0 % to believe that health promotion belonged in the workplace (compared to 55.7 % of medium businesses and 73.9 % of large businesses although half of small businesses did not know or were undecided (compared to 36.4 and 21.6 % of medium and large businesses. In total, 85.0 % of smaller businesses believed the health promotion activities currently employed in the worksite were effective (compared to 89.2 % of medium businesses and 83.1 % of large businesses. Time and funding were the most cited responses to the challenges to implementing health promoting strategies regardless of business size. Small businesses ranked morale and work/life balance the highest among a range of health promotion activities that were important for their workplace while work-related injury was the highest ranked consideration for large businesses. Conclusion

  13. Avaliação dos resultados tardios da operação de derivação cavo-pulmonar bidirecional, no tratamento paliativo de cardiopatias congênitas com câmara ventricular única Assessment of late results of bidirecional cavopulmonary shunt on paliative treatment of congenital heart disease with functional isolated ventricular chamber

    Directory of Open Access Journals (Sweden)

    Miguel Angel Maluf

    1994-06-01

    patients 1 to 13 years old (mean 7 years, who had congenital heart disease with functional isolated ventricular chamber, were submitted to bidirectional cavopulmonary shunts. Nine cases had Tricuspid Atresia (TA (7 type Ib, 1 type Ic and 1 type IIb. Five cases had Double Inlet Right ventricle (Dl RV; two cases had multiple Ventricular Septal Defects (VSD plus RV hypoplasia. One case had pulmonary atresia with Intact Ventricular septum (PA/IVS. Nine (52,9% patients had been submitted, to previous paliative operations. The operations in 12 (70,5% cases were with extracorporeal circulation (ECC and in 5 (29,4% cases with superior vena cava (SVC to right atrio (RA temporary shunt. In all cases the SVC was anastomosed to right pulmonary artery (RPA closing the pulmonary valve (PV or linking the Blalock-Taussig shunt to interrupt the pulmonary flow. There are three (17,6% deaths in the immediate postoperative period and 2 (14,2% late deaths. Twelve (70,5% patients were followed-up for 2 to 46 months. One patient was submitted to the 2 nd operation, tunnelating the inferior vena cava (IVC to RPA, with success. The assessment of bidirectional cavopulmonary flow was made with Doppler echocardiography and magnetic resonance and the pulmonary perfusion was made with radioisotopic cintilography. The indication tor the 2 nd, operation depended on the clinical evolution and assessment of arterial saturation during the cicloergometric test. The bidirectional cavo pulmonary shunt allows the progressive adaptation of the venous flow to lung and reduced ventricular volume load, preparing the patient to total venous shunt.

  14. Assessment of right ventricular longitudinal strain by 2D speckle tracking imaging compared with RV function and hemodynamics in pulmonary hypertension.

    Science.gov (United States)

    Li, Yidan; Wang, Yidan; Meng, Xiangli; Zhu, Weiwei; Lu, Xiuzhang

    2017-11-01

    The right ventricular longitudinal strain (RVLS) of pulmonary hypertension (PH) patients and its relationship with RV function parameters measured by echocardiography and hemodynamic parameters measured by right heart catheterization was investigated. According to the WHO functional class (FC), 66 PH patients were divided into FC I/II (group 1) and III/IV (group 2). RV function parameters were measured by echocardiographic examinations. Hemodynamic parameters were obtained by right heart catheterization. Patients in group 2 had higher systolic pulmonary artery pressure (sPAP; P good sensitivity and specificity. Evidence has shown that RVLS measurement can provide the much-needed and reliable information on RV function and hemodynamics. Therefore, this qualifies as a patient-friendly approach for the clinical management of PH patients.

  15. [Idiopathic ventricular arrhythmia in children. Apropos of 24 cases].

    Science.gov (United States)

    Coeurderoy, A; Almange, C; Laurent, M; Biron, Y; Leborgne, P

    1985-12-01

    The severity and prognosis of idiopathic ventricular arrhythmias in childhood were studied in 24 patients (12 boys, 12 girls) with an average age of 8 years at the time of diagnosis of the arrhythmia. Investigations included clinical assessment and analysis of basal ECG (morphology of the arrhythmias) and dynamic recordings (Holter and exercise stress testing). The clinical course was followed for an average of 3.8 years. The patients were classified in two groups: monomorphic arrhythmias (Group I) and polymorphic arrhythmias (Group II). Group I was divided into 4 subgroups: isolated ventricular extrasystoles (IA), 11 patients; ventricular extrasystoles with bursts of ventricular tachycardia (IB), 6 patients; sustained ventricular tachycardia without intercritical extrasystoles (IC), 1 patient; accelerated idioventricular rhythm (ID), 2 patients. Subgroups IA, IB and ID were characterised by the absence of symptoms, the disappearance of the arrhythmia on exercise, the decreased efficacy of antiarrhythmic drugs and an excellent prognosis. Therapeutic abstention was the rule in these patients. Patients in Group IC were characterised by the variability of their symptoms, the absence of exercise induced arrhythmias, the need for treatment in most cases and a good long-term prognosis. Group II was divided into 2 subgroups: adrenergic polymorphic ventricular tachycardia (IIA), 2 patients, and non-adrenergic polymorphic ventricular tachycardia (IIB), 2 patients. Patients in Subgroup IIA were characterised by syncope on exercise or emotion, the need for betablocker therapy which considerably improved the patients symptoms but which did not usually prevent sudden death.(ABSTRACT TRUNCATED AT 250 WORDS)

  16. Is 16-frame really superior to 8-frame gated SPECT for the assessment of left ventricular volumes and ejection fraction? Comparison of two simultaneously acquired gated SPECT studies

    International Nuclear Information System (INIS)

    Montelatici, Giulia; Sciagra, Roberto; Passeri, Alessandro; Dona, Manjola; Pupi, Alberto

    2008-01-01

    Conflicting data exist about the difference between 8- and 16-frame gated single-photon emission computed tomography (SPECT) left ventricular volumes and ejection fraction (EF); moreover, the influence of framing on detection of stress-induced functional changes is unknown. In 133 patients, two separate gated SPECT studies, one with 8 and one with 16 frames, were simultaneously acquired during a single gantry orbit using dedicated software. In 33 of 133 patients, two additional studies (with 8 and 16 frames, respectively) were acquired using arrhythmia rejection. Left ventricular EF and volumes were calculated using the QGS software. Stress-induced ischemia was identified on summed perfusion images. Arrhythmia-rejection did not influence volumes and EF independently of framing rate. Using data without arrhythmia-rejection, there was a significant difference in volumes and EF between 8 and 16 frames both in resting and post-stress gated SPECT. However, the difference was small: 2.6% for resting and 2.8% for post-stress EF. Both using 8 and 16 frames, there were significantly larger volumes and lower EF in patients with than without stress-induced ischemia. A stress-induced decrease >5 EF units was observed in 26 of 133 patients using 8 and in 23 of 133 using 16 frames, respectively, with finding agreement in 19 patients. Comparing two simultaneously acquired studies, the use of 16 instead of 8 frames has minor and predictable influence on functional data. Furthermore, there are no differences in the detection of stress-induced functional changes. The advantage of 16 over 8 frames in the daily clinical practice appears questionable. (orig.)

  17. Assessment Studies regarding the Optimal Sizing of Wind Integrated Hybrid Power Plants for Off-Grid Systems

    DEFF Research Database (Denmark)

    Petersen, Lennart; Iov, Florin; Tarnowski, German Claudio

    2018-01-01

    The paper focusses on the optimal sizing of off-grid hybrid power plants including wind power generation. A modular and scalable system topology as well as an optimal sizing algorithm for the HPP has been presented in a previous publication. In this paper, the sizing process is evaluated by means...... of assessment studies. The aim is to address the impact of renewable resource data, the required power supply availability and reactive power load demand on the optimal sizing of wind integrated off-grid HPPs....

  18. Influence of mammographic density on the diagnostic accuracy of tumor size assessment and association with breast cancer tumor characteristics

    International Nuclear Information System (INIS)

    Fasching, Peter A.; Heusinger, Katharina; Loehberg, Christian R.; Wenkel, Evelyn; Lux, Michael P.; Schrauder, Michael; Koscheck, Thomas; Bautz, Werner; Schulz-Wendtland, Ruediger; Beckmann, Matthias W.; Bani, Mayada R.

    2006-01-01

    Purpose: The accuracy of breast cancer staging involves the estimation of the tumor size for the initial decision-making in the treatment. We investigated the accuracy of tumor size estimation and the association between tumor characteristics and breast density (BD). Materials and methods: A total of 434 women with a primary diagnosis of breast cancer were included in this prospective study at a specialist breast unit. Estimated tumor characteristics included tumor size, nodal status, estrogen/progesterone receptor status, Ki-67, HER2/neu, vascular invasion. Radiomorphological data included tumor size as assessed by mammography, breast ultrasonography, and clinical examination, and American College of Radiology (ACR) categories for BD. Results: BD did not have a significant impact on the assessment of tumor size using breast ultrasound (deviation from ACR categories 1-4: 0.55-0.68 cm; P = 0.331). The deviation in mammography was significantly different dependent on BD (0.42-0.9 cm; P 2 cm). Conclusion: Breast ultrasonography is more accurate than mammography for assessing tumor size in breasts with a higher BD. The difference in tumor size assessment needs to be taken into consideration in the design of clinical trials and treatment decisions

  19. Skin Sodium Concentration Correlates with Left Ventricular Hypertrophy in CKD.

    Science.gov (United States)

    Schneider, Markus P; Raff, Ulrike; Kopp, Christoph; Scheppach, Johannes B; Toncar, Sebastian; Wanner, Christoph; Schlieper, Georg; Saritas, Turgay; Floege, Jürgen; Schmid, Matthias; Birukov, Anna; Dahlmann, Anke; Linz, Peter; Janka, Rolf; Uder, Michael; Schmieder, Roland E; Titze, Jens M; Eckardt, Kai-Uwe

    2017-06-01

    The pathogenesis of left ventricular hypertrophy in patients with CKD is incompletely understood. Sodium intake, which is usually assessed by measuring urinary sodium excretion, has been inconsistently linked with left ventricular hypertrophy. However, tissues such as skin and muscle may store sodium. Using 23 sodium-magnetic resonance imaging, a technique recently developed for the assessment of tissue sodium content in humans, we determined skin sodium content at the level of the calf in 99 patients with mild to moderate CKD (42 women; median [range] age, 65 [23-78] years). We also assessed total body overhydration (bioimpedance spectroscopy), 24-hour BP, and left ventricular mass (cardiac magnetic resonance imaging). Skin sodium content, but not total body overhydration, correlated with systolic BP ( r =0.33, P =0.002). Moreover, skin sodium content correlated more strongly than total body overhydration did with left ventricular mass ( r =0.56, P skin sodium content is a strong explanatory variable for left ventricular mass, unaffected by BP and total body overhydration. In conclusion, we found skin sodium content to be closely linked to left ventricular mass in patients with CKD. Interventions that reduce skin sodium content might improve cardiovascular outcomes in these patients. Copyright © 2017 by the American Society of Nephrology.

  20. Standardization and validation of a novel and simple method to assess lumbar dural sac size

    International Nuclear Information System (INIS)

    Daniels, M.L.A.; Lowe, J.R.; Roy, P.; Patrone, M.V.; Conyers, J.M.; Fine, J.P.; Knowles, M.R.; Birchard, K.R.

    2015-01-01

    Aim: To develop and validate a simple, reproducible method to assess dural sac size using standard imaging technology. Materials and methods: This study was institutional review board-approved. Two readers, blinded to the diagnoses, measured anterior–posterior (AP) and transverse (TR) dural sac diameter (DSD), and AP vertebral body diameter (VBD) of the lumbar vertebrae using MRI images from 53 control patients with pre-existing MRI examinations, 19 prospectively MRI-imaged healthy controls, and 24 patients with Marfan syndrome with prior MRI or CT lumbar spine imaging. Statistical analysis utilized linear and logistic regression, Pearson correlation, and receiver operating characteristic (ROC) curves. Results: AP-DSD and TR-DSD measurements were reproducible between two readers (r = 0.91 and 0.87, respectively). DSD (L1–L5) was not different between male and female controls in the AP or TR plane (p = 0.43; p = 0.40, respectively), and did not vary by age (p = 0.62; p = 0.25) or height (p = 0.64; p = 0.32). AP-VBD was greater in males versus females (p = 1.5 × 10 −8 ), resulting in a smaller dural sac ratio (DSR) (DSD/VBD) in males (p = 5.8 × 10 −6 ). Marfan patients had larger AP-DSDs and TR-DSDs than controls (p = 5.9 × 10 −9 ; p = 6.5 × 10 −9 , respectively). Compared to DSR, AP-DSD and TR-DSD better discriminate Marfan from control subjects based on area under the curve (AUC) values from unadjusted ROCs (AP-DSD p < 0.01; TR-DSD p = 0.04). Conclusion: Individual vertebrae and L1–L5 (average) AP-DSD and TR-DSD measurements are simple, reliable, and reproducible for quantitating dural sac size without needing to control for gender, age, or height. - Highlights: • DSD (L1-L5) does not differ in the AP or TR plane by gender, height, or age. • AP- and TR-DSD measures correlate well between readers with different experience. • Height is positively correlated to AP-VBD in both males and females. • Varying

  1. Genetics Home Reference: arrhythmogenic right ventricular cardiomyopathy

    Science.gov (United States)

    ... cardiomyopathy Merck Manual Consumer Version: Cardiomyopathy Merck Manual Consumer Version: Overview of Abnormal Heart Rhythms Orphanet: Arrhythmogenic right ventricular cardiomyopathy Orphanet: Familial isolated arrhythmogenic right ventricular ...

  2. Genotoxicity assessment of magnetic iron oxide nanoparticles with different particle sizes and surface coatings

    International Nuclear Information System (INIS)

    Liu, Yanping; Xia, Qiyue; Liu, Ying; Zhang, Shuyang; Cheng, Feng; Wang, Li; Li, Hongxia; Xiao, Kai; Zhong, Zhihui

    2014-01-01

    Magnetic iron oxide nanoparticles (IONPs) have been widely used for various biomedical applications such as magnetic resonance imaging and drug delivery. However, their potential toxic effects, including genotoxicity, need to be thoroughly understood. In the present study, the genotoxicity of IONPs with different particle sizes (10, 30 nm) and surface coatings (PEG, PEI) were assessed using three standard genotoxicity assays, the Salmonella typhimurium reverse mutation assay (Ames test), the in vitro mammalian chromosome aberration test, and the in vivo micronucleus assay. In the Ames test, SMG-10 (PEG coating, 10 nm) showed a positive mutagenic response in all the five test bacterial strains with and without metabolic activation, whereas SEI-10 (PEI coating, 10 nm) showed no mutagenesis in all tester strains regardless of metabolic activation. SMG-30 (PEG coating, 30 nm) was not mutagenic in the absence of metabolic activation, and became mutagenic in the presence of metabolic activation. In the chromosomal aberration test, no increase in the incidence of chromosomal aberrations was observed for all three IONPs. In the in vivo micronucleus test, there was no evidence of increased micronuclei frequencies for all three IONPs, indicating that they were not clastogenic in vivo. Taken together, our results demonstrated that IONPs with PEG coating exhibited mutagenic activity without chromosomal and clastogenic abnormalities, and smaller IONPs (SMG-10) had stronger mutagenic potential than larger ones (SMG-30); whereas, IONPs with SEI coating (SEI-10) were not genotoxic in all three standard genotoxicity assays. This suggests that the mutagenicity of IONPs depends on their particle size and surface coating. (paper)

  3. Guiding automated left ventricular chamber segmentation in cardiac imaging using the concept of conserved myocardial volume.

    Science.gov (United States)

    Garson, Christopher D; Li, Bing; Acton, Scott T; Hossack, John A

    2008-06-01

    The active surface technique using gradient vector flow allows semi-automated segmentation of ventricular borders. The accuracy of the algorithm depends on the optimal selection of several key parameters. We investigated the use of conservation of myocardial volume for quantitative assessment of each of these parameters using synthetic and in vivo data. We predicted that for a given set of model parameters, strong conservation of volume would correlate with accurate segmentation. The metric was most useful when applied to the gradient vector field weighting and temporal step-size parameters, but less effective in guiding an optimal choice of the active surface tension and rigidity parameters.

  4. The role of business size in assessing the uptake of health promoting workplace initiatives in Australia.

    Science.gov (United States)

    Taylor, A W; Pilkington, R; Montgomerie, A; Feist, H

    2016-04-21

    Worksite health promotion (WHP) initiatives are increasingly seen as having potential for large-scale health gains. While health insurance premiums are directly linked to workplaces in the USA, other countries with universal health coverage, have less incentive to implement WHP programs. Size of the business is an important consideration with small worksites less likely to implement WHP programs. The aim of this study was to identify key intervention points and to provide policy makers with evidence for targeted interventions. The worksites (n = 218) of randomly selected, working participants, aged between 30 and 65 years, in two South Australian cohort studies were surveyed to assess the practices, beliefs, and attitudes regarding WHP. A survey was sent electronically or by mail to management within each business. Smaller businesses (businesses (20-200 employees - mean 2.4) and large businesses (200+ employees - mean 2.9). Management in small businesses were less likely (31.0 %) to believe that health promotion belonged in the workplace (compared to 55.7 % of medium businesses and 73.9 % of large businesses) although half of small businesses did not know or were undecided (compared to 36.4 and 21.6 % of medium and large businesses). In total, 85.0 % of smaller businesses believed the health promotion activities currently employed in the worksite were effective (compared to 89.2 % of medium businesses and 83.1 % of large businesses). Time and funding were the most cited responses to the challenges to implementing health promoting strategies regardless of business size. Small businesses ranked morale and work/life balance the highest among a range of health promotion activities that were important for their workplace while work-related injury was the highest ranked consideration for large businesses. This study found that smaller workplaces had many barriers, beliefs and challenges regarding WHP. Often small businesses find health promotion activities a

  5. Assessment of Safety and Effectiveness of the Extracorporeal Continuous-Flow Ventricular Assist Device (BR16010) Use as a Bridge-to-Decision Therapy for Severe Heart Failure or Refractory Cardiogenic Shock: Study Protocol for Single-Arm Non-randomized, Uncontrolled, and Investigator-Initiated Clinical Trial.

    Science.gov (United States)

    Fukushima, Norihide; Tatsumi, Eisuke; Seguchi, Osamu; Takewa, Yoshiaki; Hamasaki, Toshimitsu; Onda, Kaori; Yamamoto, Haruko; Hayashi, Teruyuki; Fujita, Tomoyuki; Kobayashi, Junjiro

    2018-06-08

    The management of heart failure patients presenting in a moribund state remains challenging, despite significant advances in the field of ventricular assist systems. Bridge to decision involves using temporary devices to stabilize the hemodynamic state of such patients while further assessment is performed and a decision can be made regarding patient management. The purpose of this study (NCVC-BTD_01, National Cerebral and Cardiovascular Center-Bridge to Dicision_01) is to assess the safety and effectiveness of the newly developed extracorporeal continuous-flow ventricular assist system employing a disposable centrifugal pump with a hydrodynamically levitated bearing (BR16010) use as a bridge-to-decision therapy for patients with severe heart failure or refractory cardiogenic shock. NCVC-BTD_01 is a single-center, single-arm, open-label, exploratory, medical device, investigator-initiated clinical study. It is conducted at the National Cerebral and Cardiovascular Center in Japan. A total of nine patients will be enrolled in the study. The study was planned using Simon's minimax two-stage phase design. The primary endpoint is a composite of survival free of device-related serious adverse events and complications during device support. For left ventricular assistance, withdrawal of a trial device due to cardiac function recovery or exchange to other ventricular assist devices (VADs) for the purpose of bridge to transplantation (BTT) during 30 days after implantation will be considered study successes. For right ventricular assistance, withdrawal of tal device due to right ventricular function recovery within 30 days after implantation will be considered a study success. Secondary objectives include changes in brain natriuretic peptide levels (7 days after implantation of a trial device and the day of withdrawal of a trial device), period of mechanical ventricular support, changes in left ventricular ejection fraction (7 days after implantation of a trial device

  6. Assessment of bone biopsy needles for sample size, specimen quality and ease of use

    International Nuclear Information System (INIS)

    Roberts, C.C.; Liu, P.T.; Morrison, W.B.; Leslie, K.O.; Carrino, J.A.; Lozevski, J.L.

    2005-01-01

    To assess whether there are significant differences in ease of use and quality of samples among several bone biopsy needles currently available. Eight commonly used, commercially available bone biopsy needles of different gauges were evaluated. Each needle was used to obtain five consecutive samples from a lamb lumbar pedicle. Subjective assessment of ease of needle use, ease of sample removal from the needle and sample quality, before and after fixation, was graded on a 5-point scale. The number of attempts necessary to reach a 1 cm depth was recorded. Each biopsy specimen was measured in the gross state and after fixation. The RADI Bonopty 15 g and Kendall Monoject J-type 11 g needles were rated the easiest to use, while the Parallax Core-Assure 11 g and the Bard Ostycut 16 g were rated the most difficult. Parallax Core-Assure and Kendall Monoject needles had the highest quality specimen in the gross state; Cook Elson/Ackerman 14 g and Bard Ostycut 16 g needles yielded the lowest. The MD Tech without Trap-Lok 11 g needle had the highest quality core after fixation, while the Bard Ostycut 16 g had the lowest. There was a significant difference in pre-fixation sample length between needles (P<0.0001), despite acquiring all cores to a standard 1 cm depth. Core length and width decrease in size by an average of 28% and 42% after fixation. Bone biopsy needles vary significantly in performance. Detailed knowledge of the strengths and weaknesses of different needles is important to make an appropriate selection for each individual's practice. (orig.)

  7. Operational Risk Assessment and Management in Small and Medium-sized Enterprises

    Directory of Open Access Journals (Sweden)

    Viktorija Stasytytė

    2015-07-01

    Full Text Available Modern organizations have raised a need to actively and quickly react to the changes in external business environment, as well as in internal processes considering not only the present situation, but also evaluating possible changes and forecasting the future. Enterprise risk assessment and management, which is strongly related with foreseeing the uncertain future, becomes topical not only scientifically, but also practically seeking to reveal new and unique solutions. Operational risk management in small and medium enterprises, creating the largest part of value added in the whole European Union, demands a separate attention and coordinated decisions and means. The objective of the paper – to analyse the process of enterprise risk management in small and medium-sized enterprises, as well as to propose adequate risk management solutions for these companies. After performing a research, it was found out that small and medium enterprises more than big organizations require a risk management strategy and methodology, need to distinguish activity objectives and events influencing them, and they can efficiently apply a risk portfolio method to manage risk. In small and medium enterprises it is recommended to incorporate a risk management system based on COSO ERM model that can be modified depending on company needs and possibilities, turning it into less formal and structured and easily applicable.

  8. Assessing Statistical Competencies in Clinical and Translational Science Education: One Size Does Not Fit All

    Science.gov (United States)

    Lindsell, Christopher J.; Welty, Leah J.; Mazumdar, Madhu; Thurston, Sally W.; Rahbar, Mohammad H.; Carter, Rickey E.; Pollock, Bradley H.; Cucchiara, Andrew J.; Kopras, Elizabeth J.; Jovanovic, Borko D.; Enders, Felicity T.

    2014-01-01

    Abstract Introduction Statistics is an essential training component for a career in clinical and translational science (CTS). Given the increasing complexity of statistics, learners may have difficulty selecting appropriate courses. Our question was: what depth of statistical knowledge do different CTS learners require? Methods For three types of CTS learners (principal investigator, co‐investigator, informed reader of the literature), each with different backgrounds in research (no previous research experience, reader of the research literature, previous research experience), 18 experts in biostatistics, epidemiology, and research design proposed levels for 21 statistical competencies. Results Statistical competencies were categorized as fundamental, intermediate, or specialized. CTS learners who intend to become independent principal investigators require more specialized training, while those intending to become informed consumers of the medical literature require more fundamental education. For most competencies, less training was proposed for those with more research background. Discussion When selecting statistical coursework, the learner's research background and career goal should guide the decision. Some statistical competencies are considered to be more important than others. Baseline knowledge assessments may help learners identify appropriate coursework. Conclusion Rather than one size fits all, tailoring education to baseline knowledge, learner background, and future goals increases learning potential while minimizing classroom time. PMID:25212569

  9. Assessing food appeal and desire to eat: the effects of portion size & energy density.

    Science.gov (United States)

    Burger, Kyle S; Cornier, Marc A; Ingebrigtsen, Jan; Johnson, Susan L

    2011-09-25

    Visual presentation of food provides considerable information such as its potential for palatability and availability, both of which can impact eating behavior. We investigated the subjective ratings for food appeal and desire to eat when exposed to food pictures in a fed sample (n=129) using the computer paradigm ImageRate. Food appeal and desire to eat were analyzed for the effects of food group, portion size and energy density of the foods presented as well as by participant characteristics. Food appeal ratings were significantly higher than those for desire to eat (57.9±11.6 v. 44.7±18.0; pappeal. Food category analyses revealed that fruit was the highest rated food category for both appeal and desire, followed by discretionary foods. Additionally, overweight individuals reported higher ratings of desire to eat large portions of food compared to smaller portions (pappeal and desire (r's=-0.27; p'sappeal and desire to eat foods when assessing these ratings using the same type of metric. Additionally, relations among food appeal and desire to eat ratings and body mass show overweight individuals could be more responsive to visual foods cues in a manner that contributes to obesity.

  10. Assessing food appeal and desire to eat: the effects of portion size & energy density

    Directory of Open Access Journals (Sweden)

    Cornier Marc A

    2011-09-01

    Full Text Available Abstract Background Visual presentation of food provides considerable information such as its potential for palatability and availability, both of which can impact eating behavior. Methods We investigated the subjective ratings for food appeal and desire to eat when exposed to food pictures in a fed sample (n = 129 using the computer paradigm ImageRate. Food appeal and desire to eat were analyzed for the effects of food group, portion size and energy density of the foods presented as well as by participant characteristics. Results Food appeal ratings were significantly higher than those for desire to eat (57.9 ± 11.6 v. 44.7 ± 18.0; p r = 0.20; p p r's = - 0.27; p's Conclusions Results support the hypothesis that individuals differentiate between food appeal and desire to eat foods when assessing these ratings using the same type of metric. Additionally, relations among food appeal and desire to eat ratings and body mass show overweight individuals could be more responsive to visual foods cues in a manner that contributes to obesity.

  11. Sonographic assessment of spleen size in Saudi patients with sickle cell disease

    International Nuclear Information System (INIS)

    Al-Salem, Ahmed H.; Al-Aithan, S.; Al-Jama, A.; Al-Dabbous, I.; Bhamidipati, P.

    1998-01-01

    In patients with SCD, the spleen commonly enlarges during the first two decades of life but then undergoes autosplenectomy due to repeated attacks of vaso-occlusion and infarction. This, however, is not the case in Saudi patients with SCD (340 SCD and 23-sickle beta-thalassemia). A total of 363 patients were evaluated. There ages ranged from 1-60 years (mean 60 years). Only 24 (6.6%) of our patients had autosplenectomy. The splenic index increased with age until about 40 years of age and then gradually decreased indicating persistence of splenomegaly in our patients into an older age group. Forty-three patients (11.8%) had marked-massive splenomegaly (splenic index >120cm) and these had higher HbF levels (mean HbF=22.2%) when compared with those who had autosplenectomy (mean HbF=14.6). This is significant (P-value=0.0169) and confirms the effect of HbF on persistence of splenomegaly in SCD patients. Ultrasonography is a simple, safe and accurate method of assessing splenic size in patients with sickle cell disease. Patients with persistent splenomegaly should be followed closely for development of complications which may necessitate splenectomy. (author)

  12. Use of the Electronic Medical Record to Assess Pancreas Size in Type 1 Diabetes

    Science.gov (United States)

    Virostko, John; Hilmes, Melissa; Eitel, Kelsey; Moore, Daniel J.; Powers, Alvin C.

    2016-01-01

    Aims This study harnessed the electronic medical record to assess pancreas volume in patients with type 1 diabetes (T1D) and matched controls to determine whether pancreas volume is altered in T1D and identify covariates that influence pancreas volume. Methods This study included 25 patients with T1D and 25 age-, sex-, and weight-matched controls from the Vanderbilt University Medical Center enterprise data warehouse. Measurements of pancreas volume were made from medical imaging studies using magnetic resonance imaging (MRI) or computed tomography (CT). Results Patients with T1D had a pancreas volume 47% smaller than matched controls (41.16 ml vs. 77.77 ml, P pancreas volume normalized by subject body weight, body mass index, or body surface area (all P pancreas volume over time (~ 6% of volume/year), whereas five controls scanned a year apart did not exhibit a decline in pancreas size (P = 0.03). The pancreas was uniformly smaller on the right and left side of the abdomen. Conclusions Pancreas volume declines with disease duration in patients with T1D, suggesting a protracted pathological process that may include the exocrine pancreas. PMID:27391588

  13. Who receives bank loans? A study of lending officers' assessments of loans to growing small and medium-sized enterprises

    OpenAIRE

    Bruns, Volker

    2004-01-01

    This thesis explores factors that influence lending officers' assessments of credit requests from growing small and medium-sized enterprises (SMEs). Building on asymmetric information theory, factors identified in previous research are grouped into the theoretical categories of risk-assessment, risk-alignment, and risk-shifting. Hypotheses are developed as to what influences lending officers' credit assessments. In addition, it is hypothesized that risk-taking proclivity interacts with other ...

  14. Particle size: a missing factor in risk assessment of human exposure to toxic chemicals in settled indoor dust.

    Science.gov (United States)

    Cao, Zhi-Guo; Yu, Gang; Chen, Yong-Shan; Cao, Qi-Ming; Fiedler, Heidelore; Deng, Shu-Bo; Huang, Jun; Wang, Bin

    2012-11-15

    For researches on toxic chemicals in settled indoor dust, selection of dust fraction is a critical influencing factor to the accuracy of human exposure risk assessment results. However, analysis of the selection of dust fraction in recent studies revealed that there is no consensus. This study classified and presented researches on distribution of toxic chemicals according to dust particle size and on relationship between dust particle size and human exposure possibility. According to the literature, beyond the fact that there were no consistent conclusions on particle size distribution of adherent fraction, dust with particle size less than 100 μm should be paid more attention and that larger than 250 μm is neither adherent nor proper for human exposure risk assessment. Calculation results based on literature data show that with different selections of dust fractions, analytical results of toxic chemicals would vary up to 10-fold, which means that selecting dust fractions arbitrarily will lead to large errors in risk assessment of human exposure to toxic chemicals in settled dust. Taking into account the influence of dust particle size on risk assessment of human exposure to toxic chemicals, a new methodology for risk assessment of human exposure to toxic chemicals in settled indoor dust is proposed and human exposure parameter systems to settled indoor dust are advised to be established at national and regional scales all over the world. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Three-dimensional echocardiography: assessment of inter- and intra-operator variability and accuracy in the measurement of left ventricular cavity volume and myocardial mass

    International Nuclear Information System (INIS)

    Nadkarni, S.K.; Drangova, M.; Boughner, D.R.; Fenster, A.; Department of Medical Biophysics, Medical Sciences Building, University of Western Ontario, London, Ontario N6A 5C1

    2000-01-01

    Accurate left ventricular (LV) volume and mass estimation is a strong predictor of cardiovascular morbidity and mortality. We propose that our technique of 3D echocardiography provides an accurate quantification of LV volume and mass by the reconstruction of 2D images into 3D volumes, thus avoiding the need for geometric assumptions. We compared the accuracy and variability in LV volume and mass measurement using 3D echocardiography with 2D echocardiography, using in vitro studies. Six operators measured the LV volume and mass of seven porcine hearts, using both 3D and 2D techniques. Regression analysis was used to test the accuracy of results and an ANOVA test was used to compute variability in measurement. LV volume measurement accuracy was 9.8% (3D) and 18.4% (2D); LV mass measurement accuracy was 5% (3D) and 9.2% (2D). Variability in LV volume quantification with 3D echocardiography was %SEM inter = 13.5%, %SEM intra = 11.4%, and for 2D echocardiography was %SEM inter = 21.5%, %SEM intra = 19.1%. We derived an equation to predict uncertainty in measurement of LV volume and mass using 3D echocardiography, the results of which agreed with our experimental results to within 13%. 3D echocardiography provided twice the accuracy for LV volume and mass measurement and half the variability for LV volume measurement as compared with 2D echocardiography. (author)

  16. Comparative Assessment of the Preventive Use of Intra-Aortic Baloon Counterpulsation and Levosimendan in Patients with Coronary Heart Disease and Low Left Ventricular Ejection Fraction

    Directory of Open Access Journals (Sweden)

    V. A. Boboshko

    2012-01-01

    Full Text Available The aim of our study was to compare the efficiency of the use of intraaortic balloon counterpulsation (IABP and levosi-mendan in patients with low left ventricular ejection fraction operated on under cardiopulmonary bypass. The study included 90 patients who were randomized into three groups according to the strategy of hemodynamic support. Group A patients received IABP 24 hours before surgery. In group B, preventive IABP was combined with intraoperative levosimendan infusion. Group C patients received intraoperative levosimendan infusion only. Hemodynamics, the markers of myocardial damage and heart failure, postoperative complications and length of hospital stay were observed. The patients treated with lev-osimendan had a more stable hemodynamic profile. Troponin I level was significantly lower in Group C six hours after cardiopulmonary bypass than that in group A. Length of stay in intensive care was significantly lower in Group C. The pre-operative concentration of BNP (>360 pg/ml is a predictor of inotropic support in the postoperative period. The results of our study indicate that the use of levosimendan in high-risk patients is effective and shows the results comparable with those of intra-aortic balloon counterpulsation.

  17. Left ventricular responses to dopamine in dilated cardiomyopathy as assessed by two-dimensional echocardiography and compared with findings of thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Oda, Hirotaka

    1987-01-01

    The effects of dopamine on the left ventricular regional wall motion were studied in 11 patients with dilated cardiomyopathy by use of two-dimentional echocardiography and compared with the findings on the uptake of thallium-201. There were no significant changes in heart rate after dopamine infusion (6 μg/kg/min). However, the administration of dopamine significantly reduced PEP/ET and increased the systolic blood pressure, fractional shortening, ejection fraction and mV cf. The percentage of segments with reduced thallium-uptake area was significantly higher in abnormal wall motion segments than in normal wall segments both before and after dopamine administration. The percentage of segments with reduced thallium-uptake area was significantly higher in abnormal wall motion segments after loading than in normal wall segments before loading or in dopamine responding segments. However, in reduced uptake area, the asynergy of the left ventricle was improved significantly after dopamine administration. These results demonstrated that the abnormality of Tl-uptake was correlated roughly to the asynergy of the left ventricle, but that the state of remaining myocardium was not necessarily evaluated correctly by Tl-uptake. Dopamine loading seemed to be useful for more accurate evaluation of myocardial residual function. (author)

  18. Assessment of global and regional LV function obtained by quantitative gated SPECT using {sup 99m}Tc-tetrofosmin. Comparison with left ventricular cineangiography and echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Ban, Kazunobu; Nakajima, Toru; Aoki, Naoto; Abe, Sumihisa; Handa, Shunnosuke; Suzuki, Yutaka [Tokai Univ., Isehara, Kanagawa (Japan). School of Medicine

    1998-11-01

    The quantitative gated SPECT (QGS) software that has automatic edge detection algorithm of the left ventricle, is able to calculate LV volumes and visualize LV wall motion with perfusion throughout the cardiac cycle. We evaluated the reliability of global and regional LV function derived from QGS using {sup 99m}Tc-tetrofosmin by comparing with left ventricular cineangiography (LVG) and echocardiography (ECHO). In 22 cardiac patients, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (LVEF) were calculated. Using cinematic display, regional LV wall motion were scored on a 3-point scale (1=normal, 2=hypokinesis, 3=akinesis; WMS). EDV, ESV and LVEF correlated well with those by LVG (p<0.001 for each). Correlation between WMS derived from QGS and ECHO was high (r=0.85, p<0.001). There was an inverse correlation between WMS and LVEF (r=0.77, p<0.001). In conclusion, QGS is useful to evaluate global LV function. Regional wall motion evaluated by QGS is good enough for clinical application. (author)

  19. Resting electrocardiogram and stress myocardial perfusion imaging in the determination of left ventricular systolic function: an assessment enhancing the performance of gated SPET.

    Science.gov (United States)

    Moralidis, Efstratios; Spyridonidis, Tryfon; Arsos, Georgios; Skeberis, Vassilios; Anagnostopoulos, Constantinos; Gavrielidis, Stavros

    2010-01-01

    This study aimed to determine systolic dysfunction and estimate resting left ventricular ejection fraction (LVEF) from information collected during routine evaluation of patients with suspected or known coronary heart disease. This approach was then compared to gated single photon emission tomography (SPET). Patients having undergone stress (201)Tl myocardial perfusion imaging followed by equilibrium radionuclide angiography (ERNA) were separated into derivation (n=954) and validation (n=309) groups. Logistic regression analysis was used to develop scoring systems, containing clinical, electrocardiographic (ECG) and scintigraphic data, for the discrimination of an ERNA-LVEFstatistic (mean+/-2SD) provided values of 0.001+/-0.176, 0.071+/-0.196 and 0.040+/-0.152, respectively. The average LVEF was a better discriminator of systolic dysfunction than gated SPET-LVEF in receiver operating characteristic (ROC) analysis and identified more patients (89%) with a stress myocardial perfusion imaging variables. This model provides reliable LVEF estimations, comparable to those from (201)Tl gated SPET, and can enhance the clinical performance of the latter.

  20. Effects of sedation on echocardiographic variables of left atrial and left ventricular function in healthy cats.

    Science.gov (United States)

    Ward, Jessica L; Schober, Karsten E; Fuentes, Virginia Luis; Bonagura, John D

    2012-10-01

    Although sedation is frequently used to facilitate patient compliance in feline echocardiography, the effects of sedative drugs on echocardiographic variables have been poorly documented. This study investigated the effects of two sedation protocols on echocardiographic indices in healthy cats, with special emphasis on the assessment of left atrial size and function, as well as left ventricular diastolic performance. Seven cats underwent echocardiography (transthoracic two-dimensional, spectral Doppler, color flow Doppler and tissue Doppler imaging) before and after sedation with both acepromazine (0.1 mg/kg IM) and butorphanol (0.25 mg/kg IM), or acepromazine (0.1 mg/kg IM), butorphanol (0.25 mg/kg IM) and ketamine (1.5 mg/kg IV). Heart rate increased significantly following acepromazine/butorphanol/ketamine (mean±SD of increase, 40±26 beats/min) and non-invasive systolic blood pressure decreased significantly following acepromazine/butorphanol (mean±SD of decrease, 12±19 mmHg). The majority of echocardiographic variables were not significantly different after sedation compared with baseline values. Both sedation protocols resulted in mildly decreased left ventricular end-diastolic dimension and mildly increased left ventricular end-diastolic wall thickness. This study therefore failed to demonstrate clinically meaningful effects of these sedation protocols on echocardiographic measurements, suggesting that sedation with acepromazine, butorphanol and/or ketamine can be used to facilitate echocardiography in healthy cats.