WorldWideScience

Sample records for assay package insert

  1. Patients Comprehension of Pharmaceutical Package Inserts ...

    African Journals Online (AJOL)

    Purpose: To investigate the knowledge and attitude of outpatients regarding pharmaceutical package inserts (PPIs) in Karachi, Pakistan. Methods: The study design was cross-sectional and conducted from August to December 2013. A previously validated questionnaire was adopted, modified and revalidated. Outpatients ...

  2. A critical appraisal of medication package inserts

    Directory of Open Access Journals (Sweden)

    Pranjit Narzaree

    2015-10-01

    Full Text Available Introduction: Package Inserts (PIs refers to officially specified document that accompanies a drug for relevant, updated and unbiased information for rational drug use based on regulatory guidelines as per section 6.2 and 6.3 of schedule D of Indian Drug and cosmetic Act 1945. But some studies had shown non-uniformity with suboptimal level of informations which frequently can lead to medication errors. Hence this study was conducted to evaluate the completeness of PIs.Aim: To critically evaluate package inserts of allopathic medicines.Material and Methods: 100 allopathic drug PIs were collected from pharmacies in Rohtak and were checked for the presence of each heading as per schedule D criteria, followed by scrutiny of the information included under the heading. Indian guidelines were also compared with US FDA guidelines for PIs.Scoring of package inserts: The informations were evaluated for completeness and scored as 1 if present otherwise scored as zero for no information or partial information. Scores for each heading were calculated by totaling the scores of all the package inserts. The total scores were expressed as absolute numbers and percentages.Results:  On an average PIs analyzed for the completeness of the criteria scored 10 (Mean± SD = 9.73±2.48 out of 16. Absence of common layout and headings caused inconvenience. In comparison to US FDA guidelines it lacked, disclaimer statement, boxed warning, revision date, approval date, toll-free number etc.Conclusion: PIs don’t seem to be serving effectively because of multiple deficiencies like completeness, uniformity, absence of headings.Keywords: Critical appraisal, package inserts.

  3. Clinical information in drug package inserts in India

    Directory of Open Access Journals (Sweden)

    Shivkar Y

    2009-01-01

    Full Text Available Background: It is widely recognized that accurate and reliable product information is essential for the safe and effective use of medications. Pharmaceutical companies are the primary source of most drug information, including package inserts. Package inserts are printed leaflets accompanying marketed drug products and contain information approved by the regulatory agencies. Studies on package inserts in India, in 1996, had shown that crucial information was often missing and they lacked uniformity. Aim: To assess the presentation and completeness of clinically important information provided in the currently available package inserts in India. Materials and Methods: Package inserts accompanying allopathic drug products marketed by pharmaceutical companies in India were collected. These package inserts were analyzed for the content of clinically important information in various sections. Statistical Analysis: The results were expressed as absolute numbers and percentages. Results: Preliminary analyses revealed that most package inserts did contain information under headings, such as, therapeutic indications, contraindications, undesirable effects, etc., listed in the Drugs and Cosmetics Rules 1945. The findings indicated considerable improvement in package inserts since 1996. However, on critical evaluation it was revealed that clinically important information was not well presented and was often incomplete. Information with regard to pediatric and geriatric use was present in only 44% and 13% of the package inserts, respectively. Only five of the inserts had information on the most frequent adverse drug reactions associated with the drug. Also, information on interactions and overdosage was often missing. Conclusion: Although the package inserts appear to have improved over the past decade there is still a definite need to further refine the clinical information contained, to minimize the risks to patients. This could be brought about by self

  4. 21 CFR 310.515 - Patient package inserts for estrogens.

    Science.gov (United States)

    2010-04-01

    ... package inserts for estrogens. (a) Requirement for a patient package insert. FDA concludes that the safe... the Federal Food, Drug, and Cosmetic Act. (b) Distribution requirements. (1) For estrogen drug...) Exemptions. This section does not apply to estrogen-progestogen oral contraceptives. Labeling requirements...

  5. Evaluation of medication package inserts in Saudi Arabia

    National Research Council Canada - National Science Library

    Al-Aqeel, Sinaa A

    2012-01-01

    The aim of this study was to examine if package inserts (PIs) supplied with prescribed and over-the-counter medications in Saudi Arabia contain information relevant for the safe and appropriate use of these medications...

  6. Comparative Analysis of Patient Package Inserts of Local and ...

    African Journals Online (AJOL)

    Background and Objective: The patient package insert is an important source of drug information. The aim of this study was to evaluate and compare the PPI of the anti-infective agents manufactured in Palestine with the imported equivalents. Method: The selection criteria generated 15 different antiinfective agents available ...

  7. 21 CFR 310.501 - Patient package inserts for oral contraceptives.

    Science.gov (United States)

    2010-04-01

    ... comparing the effectiveness of oral contraceptives to other methods of contraception. (4) A boxed warning... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Patient package inserts for oral contraceptives... Patient package inserts for oral contraceptives. (a) Requirement for a patient package insert. The safe...

  8. Evaluation of medication package inserts in Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Al-aqeel SA

    2012-03-01

    Full Text Available Sinaa A Al-aqeelClinical Pharmacy Department, King Saud University, Riyadh, Kingdom of Saudi ArabiaPurpose: The aim of this study was to examine if package inserts (PIs supplied with prescribed and over-the-counter medications in Saudi Arabia contain information relevant for the safe and appropriate use of these medications.Methods: Sixty PIs for prescription-only medications (n = 37 and over-the-counter medications (n = 23 were evaluated against a set of safety criteria compiled from the literature.Results: Analyzed PIs were defective in many aspects. Particularly of concern were unclear dosage instructions, lack of measures to be taken when an administrative error was made, inappropriate presentation of side effects, and lack of measures to be taken if serious side effects occurred.Conclusion: This study indicated that information relevant to the safe and appropriate use of medications was not uniformly mentioned in the PIs analyzed. To avoid medication errors due to deficits in the current PIs, we recommend improvement in the existing PIs based on best practice for information content and design.Keywords: drug information, patient education, patient information leaflets, package inserts

  9. Controlled language and information on vaccines: application to package inserts.

    Science.gov (United States)

    Renahy, Julie; Vuitton, Dominique A; Rath, Barbara; Thomas, Izabella; de Grivel, Valerie; Cardey, Sylviane

    2015-01-01

    Any ambiguity in texts used in the communication about vaccines can not only interfere with comprehension, but also generate safety and liability issues. Within a survey on the quality of written protocols for at-risk interventional procedures and sanitary crises, we analyzed documents relating to vaccination, and among them, the "package-leaflet" of an anti-H1N1 influenza vaccine, widely disseminated to the public in 2009-2010. Among the most common mistakes, we observed that 1) language was not always adjusted to the non-specialist's level of knowledge; 2) chronology, logic, consistency, and homogeneity were often missing; 3) crucial pieces of information were disseminated all over the text, 4) use of the passive voice did not distinguish between instructions and information; 5) use of synonyms could be misleading and impair translation. We propose the use of "Controlled language" (CL) to improve the situation. By constraining lexicon, grammar and syntax, CL is a way to write documents that are clear, accurate and devoid of ambiguity. However, the set of rules necessary to write in CL is difficult to memorize. We thus developed authoring software (Rédacticiel Prolipsia) to make the creation of a CL by linguists and its use by health professionals easy and adapted to any domain. It may considerably improve the writing of vaccine package inserts/leaflets. It could be used to write information documents about vaccines and their safety, and operating procedures for professionals to prepare, store, and administer vaccines, decide upon proper indication of vaccines, and follow patients after vaccine injection.

  10. Patient-friendly medication information: Package inserts as a case in point

    OpenAIRE

    Wermuth, Cornelia; Verplaetse, Heidi

    2014-01-01

    Patient-friendly medication information: package inserts as a case in point The European Union authorization of medicinal products, following the European Medicines Agency guidelines (2009), prescribes package inserts, which are intended to provide understandable and legible scientific information for patients on safe usage of medicines (Fuchs 2009). The informational content of these inserts is derived from the scientific description of a medicinal product’s properties and the conditions ...

  11. A proposal for a drug information database and text templates for generating package inserts

    Directory of Open Access Journals (Sweden)

    Okuya R

    2013-07-01

    Full Text Available Ryo Okuya,1 Masaomi Kimura,2 Michiko Ohkura,2 Fumito Tsuchiya3 1Graduate School of Engineering and Science, 2Faculty of Engineering, Shibaura Institute of Technology, Tokyo, 3School of Pharmacy, International University of Health and Welfare, Tokyo, Japan Abstract: To prevent prescription errors caused by information systems, a database to store complete and accurate drug information in a user-friendly format is needed. In previous studies, the primary method for obtaining data stored in a database is to extract drug information from package inserts by employing pattern matching or more sophisticated methods such as text mining. However, it is difficult to obtain a complete database because there is no strict rule concerning expressions used to describe drug information in package inserts. The authors' strategy was to first build a database and then automatically generate package inserts by embedding data in the database using templates. To create this database, the support of pharmaceutical companies to input accurate data is required. It is expected that this system will work, because these companies can earn merit for newly developed drugs to decrease the effort to create package inserts from scratch. This study designed the table schemata for the database and text templates to generate the package inserts. To handle the variety of drug-specific information in the package inserts, this information in drug composition descriptions was replaced with labels and the replacement descriptions utilizing cluster analysis were analyzed. To improve the method by which frequently repeated ingredient information and/or supplementary information are stored, the method was modified by introducing repeat tags in the templates to indicate repetition and improving the insertion of data into the database. The validity of this method was confirmed by inputting the drug information described in existing package inserts and checking that the method could

  12. Evaluation of Knowledge and Awareness of Patients about Prescribed Drugs and their Package Inserts: A Cross-sectional Study

    National Research Council Canada - National Science Library

    Uma A Bhosale

    2016-01-01

      Introduction: The package insert (PI) is an officially approved mandatory document inside the package with the intention to provide relevant, recent and unbiased information for rational drug use...

  13. Analysis on descriptions of precautionary statements in package inserts of medicines

    Directory of Open Access Journals (Sweden)

    Tsuchiya F

    2012-02-01

    Full Text Available Keita Nabeta1, Masaomi Kimura2, Michiko Ohkura2, Fumito Tsuchiya31Graduate School of Engineering and Science, Shibaura Institute of Technology, Toyosu 3-7-5, Koto-ku, Tokyo, 135-8548 Japan; 2Faculty of Engineering, Shibaura Institute of Technology, Toyosu 3-7-5, Koto-ku, Tokyo, 135-8548 Japan; 3School of Pharmacy, International University of Health and Welfare, Minami-Aoyama 1-24-1, Minato-ku, Tokyo, 107-0062 JapanBackground: To prevent medical accidents, users must be informed of the cautions written in medical package inserts. To realize countermeasures by utilizing information systems, we must also implement a drug information database. However, this is not easy to develop, since the descriptions in package inserts are too complex and their information poorly structured. It is necessary to analyze package insert information and propose a data structure.Methods: We analyzed the descriptions of 'precautions for application' in package inserts via text mining methods. In order to summarize statements, we applied dependency analysis to statements and visualized their relations between predicate words and other words. Furthermore, we extracted words representing timing to execute the order.Results: We found that there are four types of statements: direct orders such as "使用する" (use, causative orders such as "使用させる" (make someone use, direct interdictions such as "使用しない" (do not use, and causative interdictions such as "使用させない" (do not make user use. As for words representing timing, we extracted six groups: "at the time of delivery," "at the time of preparation," "in use," "after use," and "at the time of storage." From these results, we obtained points of consideration concerning the subjects of orders in the statements and timing of their execution.Conclusion: From the obtained knowledge, we can define the information structure used to describe the precautionary statement. It should contain information such

  14. Membrane Insertion for the Detection of Lipopolysaccharides: Exploring the Dynamics of Amphiphile-in-Lipid Assays.

    Directory of Open Access Journals (Sweden)

    Loreen R Stromberg

    Full Text Available Shiga toxin-producing Escherichia coli is an important cause of foodborne illness, with cases attributable to beef, fresh produce and other sources. Many serotypes of the pathogen cause disease, and differentiating one serotype from another requires specific identification of the O antigen located on the lipopolysaccharide (LPS molecule. The amphiphilic structure of LPS poses a challenge when using classical detection methods, which do not take into account its lipoglycan biochemistry. Typically, detection of LPS requires heat or chemical treatment of samples and relies on bioactivity assays for the conserved lipid A portion of the molecule. Our goal was to develop assays to facilitate the direct and discriminative detection of the entire LPS molecule and its O antigen in complex matrices using minimal sample processing. To perform serogroup identification of LPS, we used a method called membrane insertion on a waveguide biosensor, and tested three serogroups of LPS. The membrane insertion technique allows for the hydrophobic association of LPS with a lipid bilayer, where the exposed O antigen can be targeted for specific detection. Samples of beef lysate were spiked with LPS to perform O antigen specific detection of LPS from E. coli O157. To validate assay performance, we evaluated the biophysical interactions of LPS with lipid bilayers both in- and outside of a flow cell using fluorescence microscopy and fluorescently doped lipids. Our results indicate that membrane insertion allows for the qualitative and reliable identification of amphiphilic LPS in complex samples like beef homogenates. We also demonstrated that LPS-induced hole formation does not occur under the conditions of the membrane insertion assays. Together, these findings describe for the first time the serogroup-specific detection of amphiphilic LPS in complex samples using a membrane insertion assay, and highlight the importance of LPS molecular conformations in detection

  15. Bacteriophage P1 pac sites inserted into the chromosome greatly increase packaging and transduction of Escherichia coli genomic DNA.

    Science.gov (United States)

    Huang, Haomin; Masters, Millicent

    2014-11-01

    The Escherichia coli bacteriophage P1 packages host chromosome separately from phage DNA, and transfers it to recipient cells at low frequency in a process called generalized transduction. Phage genomes are packaged from concatemers beginning at a specific site, pac. To increase transduction rate, we have inserted pac into the chromosome at up to five equally spaced positions; at least this many are fully tolerated in the absence of P1 infection. A single chromosomal pac greatly increases transduction of downstream markers without decreasing phage yields; 3.5 × as much total chromosomal DNA is packaged. Additional insertions decrease phage yield by > 90% and also decrease phage DNA synthesis, although less dramatically. Packaging of chromosomal markers near to and downstream of each inserted pac site is, at the same time, increased by greater than 10 fold. Transduction of markers near an inserted pac site can be increased by over 1000-fold, potentially allowing identification of such transductants by screening. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Attitudes of consumers and healthcare professionals towards the patient package inserts - a study in Palestine

    Directory of Open Access Journals (Sweden)

    Al-Ramahi R

    2012-03-01

    Full Text Available Reading the patient package inserts (PPIs is a key source of information about medications for patients. They should be clear and understandable to the general population. Objectives: The aims of this study were to obtain base-line data on the extent of reading PPIs by consumers and possible factors that might affect this; to explore the attitude of the Palestinian public and healthcare professionals towards the patient package inserts (PPIs; and to review a random sample of PPIs for the availability of different information.Methods: The first part of the study was a cross-sectional self-administered questionnaire. The questionnaire for consumers included 15 items. The questionnaire for healthcare professionals included 10 items and it was very similar to that of consumers with some modifications. In the second part, a random sample of PPIs was reviewed. In our community pharmacies, where medications are arranged according to their producing company, a researcher was asked to choose randomly 10-15 medications for every company to check for the availability of pharmacological, pharmaceutical and clinical information. Results: A total of 304 healthcare professionals out of 320 (95.0% and 223 consumers out of 240 (92.9% accepted to answer the survey. Forty five percent consumers reported that they always read the PPIs, and 29.3% said that they read the PPIs most of the times. Increased rate of reading the leaflet was found among females (P = 0.047. The preferred language for the PPIs was Arabic for most of the consumers (89.6% while it was English for most of the healthcare professionals (80.8%. 35.9% of the consumers and 43.6% of the healthcare professionals found the font size suitable. 42.3% of the consumers and 25.5% of the healthcare professionals said that they found the information in the PPIs useful and enough. The PPIs of 135 randomly sampled medications were reviewed. Many important sections were not found in the PPIs' sample. Conclusion

  17. Qualidade das bulas de fitoterápicos no Brasil | Quality of the package inserts of phytomedicines in Brazil

    Directory of Open Access Journals (Sweden)

    Marcia Maria Barros dos Passos

    2016-05-01

    Full Text Available O objetivo deste trabalho foi avaliar se as bulas de medicamentos fitoterápicos industrializados estão de acordo com a legislação nacional vigente. Foram analisadas 41 bulas dos medicamentos fitoterápicos compostos por alcachofra, castanha da Índia, ginkgo e sene, adquiridas nos sites das empresas titulares dos registros. A análise foi feita quanto à presença de itens segundo a RDC nº 47 de 2009 e ao conteúdo de indicação de uso, posologia e reações adversas comparada às bulas padrão e à literatura científica. A análise quantitativa provou que as bulas têm cumprido o que é exigido pela legislação vigente. No entanto, quanto à análise qualitativa, todos os fitoterápicos analisados neste trabalho possuíam pelo menos uma bula com erro relacionado à posologia, indicações de uso e reações adversas. Houve uma melhora gradativa das bulas dos medicamentos fitoterápicos, porém mesmo com as bulas padrão ainda existem erros, que podem induzir o paciente ao uso incorreto do medicamento. -----------------------------------------------------------------------------------------------The objective of this study was to assess whether the package inserts of industrialized phytomedicines are in line with current Brazilian legislation or not. Forty-one package inserts of phytomedicines containing artichoke, horse chestnut, ginkgo and senna were accessed in the respective proprietary websites and then analyzed. The analysis aimed to verify the presence of items required by the normative RDC 47/2009 and the usage indication, dosage and side effects compared to standard package inserts and to the scientific literature. Quantitative analysis proved that the package inserts are in accordance with the current legislation. However, in qualitative analysis, all phytomedicines analyzed in this study had at least one error related to dosage, posology or adverse reactions. A gradual improvement of the package inserts of phytomedicines has

  18. Comparative analysis of package inserts of local and imported antihypertensive medications in Palestine

    Directory of Open Access Journals (Sweden)

    Sandra A. Qatmosh

    2017-09-01

    Full Text Available Abstract Background Package inserts (PIs as a reliable reference for patients and health care providers should provide accurate, complete and up-to-date information. The purpose of the current study is to assess and compare the PIs of antihypertensive agents locally produced in Palestine and their imported counterparts. Methods Thirty-five PIs were assessed for the presence of 31 information statements using a scoring method. Word counting of 20 headings and subheadings was used to evaluate and compare local and imported PIs for information quantity. Results None of the analysed PIs fulfilled the criteria. All of them included the brand name, active ingredients, indications, directions for use, adverse drug reactions, drug–drug interactions, pregnancy and lactation considerations, and storage. Whereas none of them, either local or imported PIs, included the shelf life and instructions to convert tablets or capsules into liquid forms. Additionally, only one (5% imported and no (0% local PIs mentioned the duration of therapy. Moreover, 93.4% of local PIs were deficient in areas regarding the inactive ingredients and date of last revision, and 86.7% did not mention the drug dose and possibility of tablet splitting. Furthermore, the maximum dose was not indicated in 90% of imported and 86.7% of local PIs. In general, imported PIs contained more detailed information than their local counterparts, where the range of differences in medians between the local and imported PIs was from 1.5-fold for pregnancy considerations to >42.00-fold for the effect on the ability to drive and use machines. Conclusions The findings of this study revealed the superiority of imported over local PIs in both quality and quantity of information provided. This emphasises the need for appropriate measures to be taken by the Ministry of Health and local manufacturers to ensure efficiency of local PIs in providing accurate, complete and up-to-date information.

  19. Comparative analysis of package inserts of local and imported antihypertensive medications in Palestine.

    Science.gov (United States)

    Qatmosh, Sandra A; Koni, Amer A; Qeeno, Baraa G; Arandy, Dina A; Abu-Hashia, Maysa W; Al-Hroub, Bahaa M; Zyoud, Sa'ed H

    2017-09-25

    Package inserts (PIs) as a reliable reference for patients and health care providers should provide accurate, complete and up-to-date information. The purpose of the current study is to assess and compare the PIs of antihypertensive agents locally produced in Palestine and their imported counterparts. Thirty-five PIs were assessed for the presence of 31 information statements using a scoring method. Word counting of 20 headings and subheadings was used to evaluate and compare local and imported PIs for information quantity. None of the analysed PIs fulfilled the criteria. All of them included the brand name, active ingredients, indications, directions for use, adverse drug reactions, drug-drug interactions, pregnancy and lactation considerations, and storage. Whereas none of them, either local or imported PIs, included the shelf life and instructions to convert tablets or capsules into liquid forms. Additionally, only one (5%) imported and no (0%) local PIs mentioned the duration of therapy. Moreover, 93.4% of local PIs were deficient in areas regarding the inactive ingredients and date of last revision, and 86.7% did not mention the drug dose and possibility of tablet splitting. Furthermore, the maximum dose was not indicated in 90% of imported and 86.7% of local PIs. In general, imported PIs contained more detailed information than their local counterparts, where the range of differences in medians between the local and imported PIs was from 1.5-fold for pregnancy considerations to >42.00-fold for the effect on the ability to drive and use machines. The findings of this study revealed the superiority of imported over local PIs in both quality and quantity of information provided. This emphasises the need for appropriate measures to be taken by the Ministry of Health and local manufacturers to ensure efficiency of local PIs in providing accurate, complete and up-to-date information.

  20. Differences in pharmacogenomic biomarker information in package inserts from the United States, the United Kingdom and Japan.

    Science.gov (United States)

    Shimazawa, R; Ikeda, M

    2013-12-01

    The provision of pharmacogenomic information in drug package inserts (PIs) has become more common in recent years. The content of PIs can be tailored to meet specific requirements of the target populations. Our objective was to identify, assess and report on differences in pharmacogenomic information in PIs from the United States (USA), the United Kingdom (UK) and Japan. Package inserts were obtained from the US Food and Drug Administration (FDA) Table of Pharmacogenomic Biomarkers in Drug Labels on 1 October 2012. Corresponding PIs were obtained concurrently from Japan and the UK. We compared the pharmacogenomic information included, where the information was located, the therapeutic class of the drug, the type and purpose of the biomarker and the initial US approval year. One hundred eighteen PIs were included in the FDA table. Of the 118 PIs, 29 provided information on drug targets, 69 on metabolizing enzymes and 20 on other aspects. Genomic biomarkers were described in 71 PIs from the UK and 44 from Japan. Consistency in labelling across the three jurisdictions was greater in the 'Indications' section of the PIs than that in the 'Precautions' section. There appears to be greater concordance across countries for the biomarker information in the 'Indications' sections (UK 65% and Japan 48% relative to the US information) than that in the 'Precautions' sections (UK 41% and Japan 17%). There are substantial differences in the pharmacogenomic information included in PIs from the USA, the UK and Japan. The differences varied according to the PI sections, and type and purpose of the biomarkers. The differences appeared to vary according to the strength of the evidence supporting use of the biomarkers. Further analyses are necessary to determine the causes of these differences. © 2013 John Wiley & Sons Ltd.

  1. SLDAssay: A software package and web tool for analyzing limiting dilution assays.

    Science.gov (United States)

    Trumble, Ilana M; Allmon, Andrew G; Archin, Nancie M; Rigdon, Joseph; Francis, Owen; Baldoni, Pedro L; Hudgens, Michael G

    2017-11-01

    Serial limiting dilution (SLD) assays are used in many areas of infectious disease related research. This paper presents SLDAssay, a free and publicly available R software package and web tool for analyzing data from SLD assays. SLDAssay computes the maximum likelihood estimate (MLE) for the concentration of target cells, with corresponding exact and asymptotic confidence intervals. Exact and asymptotic goodness of fit p-values, and a bias-corrected (BC) MLE are also provided. No other publicly available software currently implements the BC MLE or the exact methods. For validation of SLDAssay, results from Myers et al. (1994) are replicated. Simulations demonstrate the BC MLE is less biased than the MLE. Additionally, simulations demonstrate that exact methods tend to give better confidence interval coverage and goodness-of-fit tests with lower type I error than the asymptotic methods. Additional advantages of using exact methods are also discussed. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Feline leukemia virus integrase and capsid packaging functions do not change the insertion profile of standard Moloney retroviral vectors.

    Science.gov (United States)

    Métais, J-Y; Topp, S; Doty, R T; Borate, B; Nguyen, A-D; Wolfsberg, T G; Abkowitz, J L; Dunbar, C E

    2010-06-01

    Adverse events linked to perturbations of cellular genes by vector insertion reported in gene therapy trials and animal models have prompted attempts to better understand the mechanisms directing viral vector integration. The integration profiles of vectors based on MLV, ASLV, SIV and HIV have all been shown to be non-random, and novel vectors with a safer integration pattern have been sought. Recently, we developed a producer cell line called CatPac that packages standard MoMLV vectors with feline leukemia virus (FeLV) gag, pol and env gene products. We now report the integration profile of this vector, asking if the FeLV integrase and capsid proteins could modify the MoMLV integration profile, potentially resulting in a less genotoxic pattern. We transduced rhesus macaque CD34+ hematopoietic progenitor cells with CatPac or standard MoMLV vectors, and determined their integration profile by LAM-PCR. We obtained 184 and 175 unique integration sites (ISs) respectively for CatPac and standard MoMLV vectors, and these were compared with 10 000 in silico-generated random IS. The integration profile for CatPac vector was similar to MoMLV and equally non-random, with a propensity for integration near transcription start sites and in highly dense gene regions. We found an IS for CatPac vector localized 715 nucleotides upstream of LMO-2, the gene involved in the acute lymphoblastic leukemia developed by X-SCID patients treated by gene therapy using MoMLV vectors. In conclusion, we found that replacement of MoMLV env, gag and pol gene products with FeLV did not alter the basic integration profile. Thus, there appears to be no safety advantage for this packaging system. However, considering the stability and efficacy of CatPac vectors, further development is warranted, using potentially safer vector backbones, for instance those with a SIN configuration.

  3. Lexis in Chinese-English Translation of Drug Package Inserts: Corpus-based Error Analysis and Its Translation Strategies.

    Science.gov (United States)

    Ying, Lin; Yumei, Zhou

    2010-12-01

    Error analysis (EA) has been broadly applied to the researches of writing, speaking, second language acquisition (SLA) and translation. This study was carried out based on Carl James' error taxonomy to investigate the distribution of lexical errors in Chinese-English (C-E) translation of drug package inserts (DPIs)(1), explore the underlying causes and propose some translation strategies for correction and reduction of lexical errors in DPIs. A translation corpus consisting of 25 DPIs translated from Chinese into English was established. Lexical errors in the corpus and the error causes were analyzed qualitatively and quantitatively. Some examples were used to analyze the lexical errors and their causes, and some strategies for translating vocabulary in DPIs were proposed according to Eugene Nida's translation theory. This study will not only help translators and medical workers reduce errors in C-E translation of vocabulary in DPIs and other types of medical texts but also shed light on the learning and teaching of C-E translation of medical texts.

  4. Cigarette package inserts can promote efficacy beliefs and sustained smoking cessation attempts: A longitudinal assessment of an innovative policy in Canada

    Science.gov (United States)

    Thrasher, James F.; Swayampakala, Kamala; Cummings, K. Michael; Hammond, David; Anshari, Dien; Krugman, Dean M.; Hardin, James W.

    2016-01-01

    Background In June 2012, Canada implemented new pictorial warnings on cigarette packages, along with package inserts with messages to promote response efficacy (i.e., perceived quitting benefits) and self-efficacy (i.e., confidence to quit). This study assessed smokers’ attention towards warnings and inserts and its relationship with efficacy beliefs, risk perceptions and cessation at follow-up. Methods Data were analysed in 2015 from a prospective online consumer panel of adult Canadian smokers surveyed every four months between September 2012 and September 2014. Generalized Estimating Equation models assessed associations between reading inserts, reading warnings and efficacy beliefs (self-efficacy, response efficacy), risk perceptions, quit attempts of any length, and sustained quit attempts (i.e., 30 days or more) at follow-up. Models adjusted for socio-demographics, smoking-related variables, and time-in-sample effects. Results Over the study period, reading warnings significantly decreased (p<0.0001) while reading inserts increased (p=0.004). More frequent reading of warnings was associated independently with stronger response efficacy (Boften/very often vs never=0.28, 95% CI: 0.11–0.46) and risk perceptions at follow-up (Boften/very often vs never=0.31, 95% CI: 0.06–0.56). More frequent reading of inserts was associated independently with stronger self-efficacy to quit at follow-up (Btwice or more vs none=0.30, 95% CI: 0.14–0.47), quit attempts (ORtwice or more vs none= 1.68, 95% CI: 1.28–2.19), and quit attempts lasting 30 days or longer (ORtwice or more vs none=1.48, 95% CI: 1.01 – 2.17). Conclusions More frequent reading of inserts was associated with self-efficacy to quit, quit attempts, and sustained quitting at follow-up, suggesting that inserts complement pictorial HWLs. PMID:26970037

  5. Cigarette package inserts can promote efficacy beliefs and sustained smoking cessation attempts: A longitudinal assessment of an innovative policy in Canada.

    Science.gov (United States)

    Thrasher, James F; Swayampakala, Kamala; Cummings, K Michael; Hammond, David; Anshari, Dien; Krugman, Dean M; Hardin, James W

    2016-07-01

    In June 2012, Canada implemented new pictorial warnings on cigarette packages, along with package inserts with messages to promote response efficacy (i.e., perceived quitting benefits) and self-efficacy (i.e., confidence to quit). This study assessed smokers' attention toward warnings and inserts and its relationship with efficacy beliefs, risk perceptions and cessation at follow-up. Data were analyzed in 2015 from a prospective online consumer panel of adult Canadian smokers surveyed every four months between September 2012 and September 2014. Generalized Estimating Equation models were estimated to assess associations between reading inserts, reading warnings and efficacy beliefs (self-efficacy, response efficacy), risk perceptions, quit attempts of any length, and sustained quit attempts (i.e., 30days or more) at follow-up. Models adjusted for socio-demographics, smoking-related variables, and time-in-sample effects. Over the study period, reading warnings significantly decreased (p<0.0001) while reading inserts increased (p=0.004). More frequent reading of warnings was associated independently with stronger response efficacy (Boften/very often vs never=0.28, 95% CI: 0.11-0.46) and risk perceptions at follow-up (Boften/very often vs never=0.31, 95% CI: 0.06-0.56). More frequent reading of inserts was associated independently with stronger self-efficacy to quit at follow-up (Btwice or more vs none=0.30, 95% CI: 0.14-0.47), quit attempts (ORtwice or more vs none=1.68, 95% CI: 1.28-2.19), and sustained quit attempts (ORtwice or more vs none=1.48, 95% CI: 1.01-2.17). More frequent reading of inserts was associated with self-efficacy to quit, quit attempts, and sustained quitting at follow-up, suggesting that inserts complement pictorial HWLs. Copyright © 2016. Published by Elsevier Inc.

  6. Malaria rapid diagnostic kits: quality of packaging, design and labelling of boxes and components and readability and accuracy of information inserts

    Directory of Open Access Journals (Sweden)

    Bruggeman Cathrien

    2011-02-01

    Full Text Available Abstract Background The present study assessed malaria RDT kits for adequate and correct packaging, design and labelling of boxes and components. Information inserts were studied for readability and accuracy of information. Methods Criteria for packaging, design, labelling and information were compiled from Directive 98/79 of the European Community (EC, relevant World Health Organization (WHO documents and studies on end-users' performance of RDTs. Typography and readability level (Flesch-Kincaid grade level were assessed. Results Forty-two RDT kits from 22 manufacturers were assessed, 35 of which had evidence of good manufacturing practice according to available information (i.e. CE-label affixed or inclusion in the WHO list of ISO13485:2003 certified manufacturers. Shortcomings in devices were (i insufficient place for writing sample identification (n = 40 and (ii ambiguous labelling of the reading window (n = 6. Buffer vial labels were lacking essential information (n = 24 or were of poor quality (n = 16. Information inserts had elevated readability levels (median Flesch Kincaid grade 8.9, range 7.1 - 12.9 and user-unfriendly typography (median font size 8, range 5 - 10. Inadequacies included (i no referral to biosafety (n = 18, (ii critical differences between depicted and real devices (n = 8, (iii figures with unrealistic colours (n = 4, (iv incomplete information about RDT line interpretations (n = 31 and no data on test characteristics (n = 8. Other problems included (i kit names that referred to Plasmodium vivax although targeting a pan-species Plasmodium antigen (n = 4, (ii not stating the identity of the pan-species antigen (n = 2 and (iii slight but numerous differences in names displayed on boxes, device packages and information inserts. Three CE labelled RDT kits produced outside the EC had no authorized representative affixed and the shape and relative dimensions of the CE symbol affixed did not comply with the Directive 98/79/EC

  7. Malaria rapid diagnostic kits: quality of packaging, design and labelling of boxes and components and readability and accuracy of information inserts.

    Science.gov (United States)

    Gillet, Philippe; Maltha, Jessica; Hermans, Veerle; Ravinetto, Raffaella; Bruggeman, Cathrien; Jacobs, Jan

    2011-02-13

    The present study assessed malaria RDT kits for adequate and correct packaging, design and labelling of boxes and components. Information inserts were studied for readability and accuracy of information. Criteria for packaging, design, labelling and information were compiled from Directive 98/79 of the European Community (EC), relevant World Health Organization (WHO) documents and studies on end-users' performance of RDTs. Typography and readability level (Flesch-Kincaid grade level) were assessed. Forty-two RDT kits from 22 manufacturers were assessed, 35 of which had evidence of good manufacturing practice according to available information (i.e. CE-label affixed or inclusion in the WHO list of ISO13485:2003 certified manufacturers). Shortcomings in devices were (i) insufficient place for writing sample identification (n=40) and (ii) ambiguous labelling of the reading window (n=6). Buffer vial labels were lacking essential information (n=24) or were of poor quality (n=16). Information inserts had elevated readability levels (median Flesch Kincaid grade 8.9, range 7.1-12.9) and user-unfriendly typography (median font size 8, range 5-10). Inadequacies included (i) no referral to biosafety (n=18), (ii) critical differences between depicted and real devices (n=8), (iii) figures with unrealistic colours (n=4), (iv) incomplete information about RDT line interpretations (n=31) and no data on test characteristics (n=8). Other problems included (i) kit names that referred to Plasmodium vivax although targeting a pan-species Plasmodium antigen (n=4), (ii) not stating the identity of the pan-species antigen (n=2) and (iii) slight but numerous differences in names displayed on boxes, device packages and information inserts. Three CE labelled RDT kits produced outside the EC had no authorized representative affixed and the shape and relative dimensions of the CE symbol affixed did not comply with the Directive 98/79/EC. Overall, RDTs with evidence of GMP scored better

  8. Consumer and health literacy: The need to better design tobacco-cessation product packaging, labels, and inserts.

    Science.gov (United States)

    Weiss, Stephanie M; Smith-Simone, Stephanie Y

    2010-03-01

    Tobacco-cessation product packaging and instruction materials may not be appropriate for some smokers and may contribute to the underuse and misuse of evidence-based treatments. The dual goals of this project are to analyze literacy levels of Food and Drug Administration (FDA)-approved and non-approved tobacco-cessation product packaging, directions, and claims, and to identify and categorize claims found on product packaging. The Campaign for Tobacco Free Kids (CTFK) maintains the Quitting and Reducing Tobacco Use Inventory of Products (QuiTIP) database, which catalogs products marketed and sold to consumers to reduce or quit use of tobacco products. It also includes all medications approved by the FDA for tobacco cessation as well as a sample of non-approved products such as homeopathic, herbal, nutritional, or dietary supplements commonly marketed as either cessation aids or alternative tobacco/nicotine products. This paper assesses the reading levels required to understand product packaging, labeling, and instructions using the Simple Measure of Gobbledygook (SMOG) and identifies claims on the product package labels using standard qualitative methods. Key findings show that the average reading levels needed to understand instructions for both FDA-approved and non-approved cessation products are above the reading levels recommended to ensure maximum comprehension. Improving the packaging and directions of evidence-based tobacco-cessation products so that they are preferably at or below a fifth-grade reading level, along with using consumer-based design principles to develop packaging, may help smokers take advantage of and correctly use products that will greatly increase their chances of successful quitting. 2010 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  9. Regulation of the statements in the information on drug metabolizing enzyme in the package insert--the present regulation and its history in Japan, the U.S. and the U.K.

    Science.gov (United States)

    Watanabe, Shinichi; Misu, Takashi; Kurihara, Teruko; Suzuki, Satoko; Sakurada, Tomoya; Satoh, Nobunori; Ueda, Shiro

    2008-01-01

    The information about a drug interaction is specified as a section which should be printed on the package insert in Japan, the U.S. and the U.K. In Japan, the information on drug metabolizing enzymes is described in the precautions for use in the package insert of many pharmaceutical agents following the incidence of the harmful effects of sorivudine. Since many elderly people suffer from two or more diseases as a result of aging and multiple pharmaceuticals are prescribed for them, the risk of drug interactions is increased. The therapeutic category where the most statements regarding drug metabolizing enzyme were in the package inserts, is hypnotics and sedatives, and anxiolytics; 100 out of 306 drugs include a statement about drug metabolizing enzymes. In the elderly aged 75 and over, regardless of whether the medicine is received in the hospital or by pharmacy preparation, in about 70 percent of the patients, three or more types of pharmaceutical agents are prescribed. Thus, although the information about the drug metabolizing enzyme is provided to the medical staff, in order to properly utilize the information, it is necessary to check whether the information about the same drug metabolizing enzyme is described in the package insert of the other pharmaceuticals that the patient is concurrently receiving. A means by which to quickly and easily retrieve the information about the drug metabolizing enzyme printed in the package is necessary and such a tool will be developed in the near future.

  10. Evolução histórica das bulas de medicamentos no Brasil Historical evolution of package inserts in Brazil

    Directory of Open Access Journals (Sweden)

    Telma Rodrigues Caldeira

    2008-04-01

    Full Text Available No Brasil, a bula é usada como fonte de informação sobre medicamentos. O estudo desenvolveu uma análise de sua evolução histórica, procurando observar a influência do desenvolvimento científico, da globalização da informação e das diferentes políticas de saúde. Procedeu-se uma revisão retrospectiva da legislação sanitária brasileira até 1920, ano da instituição do Departamento Nacional de Saúde Pública. A análise documental sobre a evolução da regulamentação sanitária no Brasil se iniciou pela Coleção Farmácia Brasileira - Portarias Sanitárias. Na segunda etapa as normas foram pesquisadas nos portais: VISALEGIS - Legislação em Vigilância Sanitária, Portal de Legislação do Sistema de Informações do Congresso Nacional e Sistema de Legislação da Saúde - Saúde Legis. A bula tornou-se um importante veículo informativo no Brasil, passou por profundas transformações regulamentares na segunda metade do século XX. Entre 1946 e 2006 o número de itens obrigatórios aumentou e sua descrição aprofundou. Entretanto, a padronização da informação para os medicamentos com o mesmo princípio ativo não se efetivou, não obstante sua importância e apesar das diferentes iniciativas observadas nas normas legais.In Brazil, package inserts provide key information on pharmaceuticals. The current study analyzes the evolution of package inserts and the impact on this process by scientific research and development, globalization of information, and various health policies. The study began with a retrospective review of Brazilian health legislation until 1920, the year when the National Public Health Department was created. The analysis of documents on the evolution of health regulation in Brazil began with the Brazilian Pharmaceutical Collection - Health Rulings. The second stage of the study involved a search of standards and norms in VISALEGIS: Health Surveillance Legislation, Portal for Legislation from the

  11. Mistaken identity of an open reading frame proposed for PCR-based identification of Mycoplasma bovis and the effect of polymorphisms and insertions on assay performance

    Science.gov (United States)

    Mycoplasma bovis is an important cause of disease in cattle and bison. Because the bacterium requires specialized growth conditions many diagnostic laboratories routinely use PCR to replace or complement conventional isolation and identification methods. A frequently used target of such assays is th...

  12. Insertion devices

    CERN Document Server

    Bahrdt, J

    2006-01-01

    The interaction of an insertion device with the electron beam in a storage ring is discussed. The radiation property including brightness, ux and polarization of an ideal and real planar and helical / elliptical device is described. The magnet design of planar, helical, quasiperiodic devices and of devices with a reduced on axis power density are resumed.

  13. Calorimeter insertion

    CERN Multimedia

    2006-01-01

    Calorimeter insertion between toroids in the ATLAS experiment detector Calorimeters are surrounding the inner detector. Calorimeters will absorb and measure the energies of the most charged and neutral particles after the collisions. The saved energy in the calorimeter is detected and converted to signals that are taken out with data taking electronics.

  14. Packaging fluency

    DEFF Research Database (Denmark)

    Mocanu, Ana; Chrysochou, Polymeros; Bogomolova, Svetlana

    2011-01-01

    Research on packaging stresses the need for packaging design to read easily, presuming fast and accurate processing of product-related information. In this paper we define this property of packaging as “packaging fluency”. Based on the existing marketing and cognitive psychology literature...

  15. Microelectronic packaging

    CERN Document Server

    Datta, M; Schultze, J Walter

    2004-01-01

    Microelectronic Packaging analyzes the massive impact of electrochemical technologies on various levels of microelectronic packaging. Traditionally, interconnections within a chip were considered outside the realm of packaging technologies, but this book emphasizes the importance of chip wiring as a key aspect of microelectronic packaging, and focuses on electrochemical processing as an enabler of advanced chip metallization.Divided into five parts, the book begins by outlining the basics of electrochemical processing, defining the microelectronic packaging hierarchy, and emphasizing the impac

  16. MEMS packaging

    CERN Document Server

    Hsu , Tai-Ran

    2004-01-01

    MEMS Packaging discusses the prevalent practices and enabling techniques in assembly, packaging and testing of microelectromechanical systems (MEMS). The entire spectrum of assembly, packaging and testing of MEMS and microsystems, from essential enabling technologies to applications in key industries of life sciences, telecommunications and aerospace engineering is covered. Other topics included are bonding and sealing of microcomponents, process flow of MEMS and microsystems packaging, automated microassembly, and testing and design for testing.The Institution of Engineering and Technology is

  17. Watermarking spot colors in packaging

    Science.gov (United States)

    Reed, Alastair; Filler, TomáÅ.¡; Falkenstern, Kristyn; Bai, Yang

    2015-03-01

    In January 2014, Digimarc announced Digimarc® Barcode for the packaging industry to improve the check-out efficiency and customer experience for retailers. Digimarc Barcode is a machine readable code that carries the same information as a traditional Universal Product Code (UPC) and is introduced by adding a robust digital watermark to the package design. It is imperceptible to the human eye but can be read by a modern barcode scanner at the Point of Sale (POS) station. Compared to a traditional linear barcode, Digimarc Barcode covers the whole package with minimal impact on the graphic design. This significantly improves the Items per Minute (IPM) metric, which retailers use to track the checkout efficiency since it closely relates to their profitability. Increasing IPM by a few percent could lead to potential savings of millions of dollars for retailers, giving them a strong incentive to add the Digimarc Barcode to their packages. Testing performed by Digimarc showed increases in IPM of at least 33% using the Digimarc Barcode, compared to using a traditional barcode. A method of watermarking print ready image data used in the commercial packaging industry is described. A significant proportion of packages are printed using spot colors, therefore spot colors needs to be supported by an embedder for Digimarc Barcode. Digimarc Barcode supports the PANTONE spot color system, which is commonly used in the packaging industry. The Digimarc Barcode embedder allows a user to insert the UPC code in an image while minimizing perceptibility to the Human Visual System (HVS). The Digimarc Barcode is inserted in the printing ink domain, using an Adobe Photoshop plug-in as the last step before printing. Since Photoshop is an industry standard widely used by pre-press shops in the packaging industry, a Digimarc Barcode can be easily inserted and proofed.

  18. A real-time PCR assay with improved specificity for detection and discrimination of all clinically relevant Bordetella species by the presence and distribution of three insertion sequence elements

    NARCIS (Netherlands)

    L.D. Roorda (Lieuwe); J. Buitenwerf (Johannes); J.M. Ossewaarde (Jacobus); A. van der Zee (Anneke)

    2011-01-01

    textabstractBackground: In Dutch laboratories molecular detection of B. pertussis and B. parapertussis is commonly based on insertion sequences IS481 and IS1001, respectively. Both IS elements are more widely spread among Bordetella species. Both Bordetella holmesii, and B. bronchiseptica can

  19. Environmental packaging

    OpenAIRE

    Davies, Gareth Benjamin Harverd

    2006-01-01

    This thesis was submitted for the degree of Doctor of Philosophy and awarded by Brunel University. The food packaging industry is a £300bn global industry growing at a rate of 12% per year and increasingly favouring polymer or polymer-based materials. This generates 58m tonnes of "plastic" packaging waste annually in the EU and poses significant challenges for management given existing legislative constraints and increasing concerns surrounding the environmental impacts. The government, co...

  20. Yucca Mountain Waste Package Closure System

    Energy Technology Data Exchange (ETDEWEB)

    Herschel Smartt; Arthur Watkins; David Pace; Rodney Bitsoi; Eric Larsen; Timothy McJunkin; Charles Tolle

    2006-04-01

    The current disposal path for high-level waste is to place the material into secure waste packages that are inserted into a repository. The Idaho National Laboratory has been tasked with the development, design, and demonstration of the waste package closure system for the repository project. The closure system design includes welding three lids and a purge port cap, four methods of nondestructive examination, and evacuation and backfill of the waste package, all performed in a remote environment. A demonstration of the closure system will be performed with a full-scale waste package.

  1. Yucca Mountain Waste Package Closure System

    Energy Technology Data Exchange (ETDEWEB)

    shelton-davis; Colleen Shelton-Davis; Greg Housley

    2005-10-01

    The current disposal path for high-level waste is to place the material into secure waste packages that are inserted into a repository. The Idaho National Laboratory has been tasked with the development, design, and demonstration of the waste package closure system for the repository project. The closure system design includes welding three lids and a purge port cap, four methods of nondestructive examination, and evacuation and backfill of the waste package, all performed in a remote environment. A demonstration of the closure system will be performed with a full-scale waste package.

  2. Tie rod insertion test

    CERN Multimedia

    B. LEVESY

    2002-01-01

    The superconducting coil is inserted in the outer vaccum tank and supported by a set of tie rods. These tie rods are made of titanium alloy. This test reproduce the final insertion of the tie rods inside the outer vacuum tank.

  3. Measurement of dabigatran: previously demonstrated Hemoclot® Thrombin Inhibitor assay reagent instability on Sysmex CS-2100i is no longer an issue

    DEFF Research Database (Denmark)

    Comuth, Willemijn; Faaborg, Louise; Henriksen, Linda Østervig

    2017-01-01

    The Hemoclot® Thrombin Inhibitor (HTI) assay has been recommended for measurement of dabigatran concentrations in specific clinical situations. Traditionally, reagents for biochemical assays are prepared from instructions found in the package insert. For the HTI reagents the manufacturer recommends...... incubating the reagents much longer than indicated in the package insert. These recommendations are added to the application sheets designed for different analyzers. Many clinicians and laboratory personnel may be unaware of the discrepancy between the two instructions, resulting in incorrect handling...... of the reagents. The aim of this study was to investigate the effect of the two different preparation methods on reagent stability and test results. For the standard concentration range, reagent stability on Sysmex CS-2100i was only two hours instead of the eight hours indicated by the producer when following...

  4. A real-time PCR assay with improved specificity for detection and discrimination of all clinically relevant Bordetella species by the presence and distribution of three Insertion Sequence elements

    Directory of Open Access Journals (Sweden)

    Ossewaarde Jacobus M

    2011-01-01

    Full Text Available Abstract Background In Dutch laboratories molecular detection of B. pertussis and B. parapertussis is commonly based on insertion sequences IS481 and IS1001, respectively. Both IS elements are more widely spread among Bordetella species. Both Bordetella holmesii, and B. bronchiseptica can harbour IS481. Also, IS1001 is found among B. bronchiseptica. IS481, and IS1001 based PCR thus lacks specificity when used for detection of specific Bordetella spp. Findings We designed a PCR based on IS1002, another IS element that is present among Bordetella species, and exploited it as a template in combination with PCR for IS481, and IS1001. In combining the PCRs for IS481, IS1001, and IS1002, and including an inhibition control, we were able to detect and discriminate all clinically relevant Bordetella species. Conclusions We developed an improved PCR method for specific detection of B. pertussis, B. parapertussis, B. holmesii, and B. bronchiseptica.

  5. Circular permutant GFP insertion folding reporters

    Science.gov (United States)

    Waldo, Geoffrey S [Santa Fe, NM; Cabantous, Stephanie [Los Alamos, NM

    2008-06-24

    Provided are methods of assaying and improving protein folding using circular permutants of fluorescent proteins, including circular permutants of GFP variants and combinations thereof. The invention further provides various nucleic acid molecules and vectors incorporating such nucleic acid molecules, comprising polynucleotides encoding fluorescent protein circular permutants derived from superfolder GFP, which polynucleotides include an internal cloning site into which a heterologous polynucleotide may be inserted in-frame with the circular permutant coding sequence, and which when expressed are capable of reporting on the degree to which a polypeptide encoded by such an inserted heterologous polynucleotide is correctly folded by correlation with the degree of fluorescence exhibited.

  6. Comparing Leaf and Root Insertion

    Directory of Open Access Journals (Sweden)

    Jaco Geldenhuys

    2010-07-01

    Full Text Available We consider two ways of inserting a key into a binary search tree: leaf insertion which is the standard method, and root insertion which involves additional rotations. Although the respective cost of constructing leaf and root insertion binary search trees trees, in terms of comparisons, are the same in the average case, we show that in the worst case the construction of a root insertion binary search tree needs approximately 50% of the number of comparisons required by leaf insertion.

  7. Mars Observer Orbit Insertion Briefing

    Science.gov (United States)

    1993-01-01

    Steve Wall is the host of this video entitled, "Return to the Red Planet". Live animation of the Mars Observer orbiting Mars is presented. Steve Wall explains the spacecraft insertion maneuver and also explains the purpose for the Mars Observer launch. Live coverage of the Cape Canaveral launch of the Mars Observer is also presented. Suzanne Dodd, Chief of the Mission Planning team describes the burn start and how the spacecraft will be captured by Mars' gravity. Glenn Cunningham, Mars Observer Project Manager, gives background information on the Mars Observer and describes the organizations behind the Mars Observer Spacecraft, such as the Deep Space Network, the Mission Operation Support Office, Science Investigators, the Flight Engineering Office, Operations Office, and the Ground Data System Office. Dr. William Piotrowski, Acting Director, Solar System Exploration Division, NASA, talks about the purpose of the Mars Pathfinder which is to develop the technology and systems for landing small science packages on Mars. Mr. Roger Gibbs, Former Mars Observer Spacecraft Systems Engineer, tells us how the Mars Observer was built and describes the structural elements on the Mars Observer. The 11-month cruise period for the spacecraft is given by Joseph Beerer, Manager of the Engineering office. The thrust for the Mars Orbit Insertion is described by Ronald Klemetson, Technical Manager, Propulsion Subsystem Jet Propulsion Laboratory (JPL). George Chen, Lead Engineer Attitude and Articulation Subsystem Spacecraft Team, explains the importance of the attitude control engines on the Spacecraft. Marvin Traxler, Manager of Tracking and Data Acquisition, describes how searching for a signal from the Mars Observer works. See NONP-NASA-VT-2000081555 for a continuation of this discussion with Marvin Traxler.

  8. The LHC Insertion Magnets

    CERN Document Server

    Ostojic, R

    2002-01-01

    The Large Hadron Collider comprises eight insertions, four of which are dedicated to the LHC experiments while the others are used for the major collider systems. The various functions of the insertions are fulfilled by a variety of magnet systems, most of them based on the technology of NbTi superconductors cooled by superfluid helium at 1.9 K. A number of stand-alone magnets in the matching sections are operated at 4.5 K, while in the high radiation areas specialised resistive magnets are used. In this paper, we review the concepts underlying the design of the LHC insertions, and report on the design, procurement and testing of the various specialised magnet systems.

  9. ISABELLE insertion quadrupoles

    Energy Technology Data Exchange (ETDEWEB)

    Kaugerts, J.; Polk, I.; Sampson, W.; Dahl, P.F.

    1979-01-01

    Beam focussing and control at the beam intersection regions of ISABELLE is accomplished by a number of superconducting insertion quadrupoles. These magnets differ from the standard ISABELLE quadrupoles in various ways. In particular, the requirements of limited space near the intersections and aperture for beam extraction impose constraints on their configuration. To achieve optimum beam focussing and provide tuning flexibility calls for stronger quadrupole trim windings than those in the standard quadrupoles. The magnetic and mechanical design of the insertion quadrupoles and their associated correction and steering windings to accomplish the above tasks is presented.

  10. The Composite Insertion Electrode

    DEFF Research Database (Denmark)

    Atlung, Sven; Zachau-Christiansen, Birgit; West, Keld

    1984-01-01

    . The theoretical basis for such electrodes is discussedand, using a simplified model, equations are derived to describe the distribution of potential and current duringdischarge/charge operation. Under the assumption that the insertion compound particles are small enough to ensureequilibrium, and that the local...... electrode potential depends linearly on the degree of insertion, these equations are solvedto obtain analytical expressions for the discharge curve. It is shown that the parameters which determine the dischargebehavior for a given discharge current are simply related to the effective ionic and electronic...... conductivities, the thicknessof the electrode, the volume fractions, and the slope of the potential curve....

  11. Insertion in Persian

    Science.gov (United States)

    Kambuziya, Aliyeh Kord-e Zafaranlu; Dehghan, Masoud

    2011-01-01

    This paper investigates epenthesis process in Persian to catch some results in relating to vowel and consonant insertion in Persian lexicon. This survey has a close relationship to the description of epenthetic consonants and the conditions in which these consonants are used. Since no word in Persian may begin with a vowel, so that hiatus can't be…

  12. Inserting the CMS solenoid

    CERN Multimedia

    Maximilien Brice

    2005-01-01

    The huge superconducting solenoid for CMS is inserted into the cryostat barrel. CMS uses the world's largest thin solenoid, in terms of energy stored, and is 12 m long, with a diameter of 6 m and weighing 220 tonnes. When turned on the magnet will produce a field strength of 4 T using superconducting niobium-titanium material at 4.5 K.

  13. Pixel detector insertion

    CERN Multimedia

    CMS

    2015-01-01

    Insertion of the Pixel Tracker, the 66-million-channel device used to pinpoint the vertex of each colliding proton pair, located at the heart of the detector. The geometry of CMS is a cylinder lying on its side (22 meters long and 15 meters high in dia

  14. 48 CFR 1852.211-70 - Packaging, handling, and transportation.

    Science.gov (United States)

    2010-10-01

    ... transportation. 1852.211-70 Section 1852.211-70 Federal Acquisition Regulations System NATIONAL AERONAUTICS AND... and Clauses 1852.211-70 Packaging, handling, and transportation. As prescribed in 1811.404-70, insert the following clause: Packaging, Handling, and Transportation (SEPT 2005) (a) The Contractor shall...

  15. Parent Training Packages

    Science.gov (United States)

    Stowitschek, Joseph J.; Hofmeister, Alan

    1975-01-01

    Discusses the current development of training packages for educating parents to help their children develop self-help, math, reading, and spelling skills. Two packages are described: (1) a multimedia package monitored by a professional in training workshops for parents of mentally retarded children; and (2) pencil and paper packages in which…

  16. Using PATIMDB to create bacterial transposon insertion mutant libraries.

    Science.gov (United States)

    Urbach, Jonathan M; Wei, Tao; Liberati, Nicole; Grenfell-Lee, Daniel; Villanueva, Jacinto; Wu, Gang; Ausubel, Frederick M

    2009-04-01

    PATIMDB is a software package for facilitating the generation of transposon mutant insertion libraries. The software has two main functions: process tracking and automated sequence analysis. The process tracking function specifically includes recording the status and fates of multiwell plates and samples in various stages of library construction. Automated sequence analysis refers specifically to the pipeline of sequence analysis starting with ABI files from a sequencing facility and ending with insertion location identifications. The protocols in this unit describe installation and use of PATIMDB software.

  17. Mechanisms for Complex Chromosomal Insertions.

    Science.gov (United States)

    Gu, Shen; Szafranski, Przemyslaw; Akdemir, Zeynep Coban; Yuan, Bo; Cooper, Mitchell L; Magriñá, Maria A; Bacino, Carlos A; Lalani, Seema R; Breman, Amy M; Smith, Janice L; Patel, Ankita; Song, Rodger H; Bi, Weimin; Cheung, Sau Wai; Carvalho, Claudia M B; Stankiewicz, Paweł; Lupski, James R

    2016-11-01

    Chromosomal insertions are genomic rearrangements with a chromosome segment inserted into a non-homologous chromosome or a non-adjacent locus on the same chromosome or the other homologue, constituting ~2% of nonrecurrent copy-number gains. Little is known about the molecular mechanisms of their formation. We identified 16 individuals with complex insertions among 56,000 individuals tested at Baylor Genetics using clinical array comparative genomic hybridization (aCGH) and fluorescence in situ hybridization (FISH). Custom high-density aCGH was performed on 10 individuals with available DNA, and breakpoint junctions were fine-mapped at nucleotide resolution by long-range PCR and DNA sequencing in 6 individuals to glean insights into potential mechanisms of formation. We observed microhomologies and templated insertions at the breakpoint junctions, resembling the breakpoint junction signatures found in complex genomic rearrangements generated by replication-based mechanism(s) with iterative template switches. In addition, we analyzed 5 families with apparently balanced insertion in one parent detected by FISH analysis and found that 3 parents had additional small copy-number variants (CNVs) at one or both sides of the inserting fragments as well as at the inserted sites. We propose that replicative repair can result in interchromosomal complex insertions generated through chromothripsis-like chromoanasynthesis involving two or three chromosomes, and cause a significant fraction of apparently balanced insertions harboring small flanking CNVs.

  18. Mechanisms for Complex Chromosomal Insertions.

    Directory of Open Access Journals (Sweden)

    Shen Gu

    2016-11-01

    Full Text Available Chromosomal insertions are genomic rearrangements with a chromosome segment inserted into a non-homologous chromosome or a non-adjacent locus on the same chromosome or the other homologue, constituting ~2% of nonrecurrent copy-number gains. Little is known about the molecular mechanisms of their formation. We identified 16 individuals with complex insertions among 56,000 individuals tested at Baylor Genetics using clinical array comparative genomic hybridization (aCGH and fluorescence in situ hybridization (FISH. Custom high-density aCGH was performed on 10 individuals with available DNA, and breakpoint junctions were fine-mapped at nucleotide resolution by long-range PCR and DNA sequencing in 6 individuals to glean insights into potential mechanisms of formation. We observed microhomologies and templated insertions at the breakpoint junctions, resembling the breakpoint junction signatures found in complex genomic rearrangements generated by replication-based mechanism(s with iterative template switches. In addition, we analyzed 5 families with apparently balanced insertion in one parent detected by FISH analysis and found that 3 parents had additional small copy-number variants (CNVs at one or both sides of the inserting fragments as well as at the inserted sites. We propose that replicative repair can result in interchromosomal complex insertions generated through chromothripsis-like chromoanasynthesis involving two or three chromosomes, and cause a significant fraction of apparently balanced insertions harboring small flanking CNVs.

  19. Waste Package Lifting Calculation

    Energy Technology Data Exchange (ETDEWEB)

    H. Marr

    2000-05-11

    The objective of this calculation is to evaluate the structural response of the waste package during the horizontal and vertical lifting operations in order to support the waste package lifting feature design. The scope of this calculation includes the evaluation of the 21 PWR UCF (pressurized water reactor uncanistered fuel) waste package, naval waste package, 5 DHLW/DOE SNF (defense high-level waste/Department of Energy spent nuclear fuel)--short waste package, and 44 BWR (boiling water reactor) UCF waste package. Procedure AP-3.12Q, Revision 0, ICN 0, calculations, is used to develop and document this calculation.

  20. Packaging for Food Service

    Science.gov (United States)

    Stilwell, E. J.

    1985-01-01

    Most of the key areas of concern in packaging the three principle food forms for the space station were covered. It can be generally concluded that there are no significant voids in packaging materials availability or in current packaging technology. However, it must also be concluded that the process by which packaging decisions are made for the space station feeding program will be very synergistic. Packaging selection will depend heavily on the preparation mechanics, the preferred presentation and the achievable disposal systems. It will be important that packaging be considered as an integral part of each decision as these systems are developed.

  1. Insertion device and method for accurate and repeatable target insertion

    Science.gov (United States)

    Gubeli, III, Joseph F.; Shinn, Michelle D.; Bevins, Michael E.; Dillon-Townes, Lawrence; Neil, George R.

    2017-07-04

    The present invention discloses a device and a method for inserting and positioning a target within a free electron laser, particle accelerator, or other such device that generates or utilizes a beam of energy or particles. The system includes a three-point registration mechanism that insures angular and translational accuracy and repeatability of positioning upon multiple insertions within the same structure.

  2. Enzyme assays

    OpenAIRE

    Bisswanger, Hans

    2014-01-01

    The essential requirements for enzyme assays are described and frequently occurring errors and pitfalls as well as their avoidance are discussed. The main factors, which must be considered for assaying enzymes, are temperature, pH, ionic strength and the proper concentrations of the essential components like substrates and enzymes. Standardization of these parameters would be desirable, but the diversity of the features of different enzymes prevents unification of assay conditions. Neverthele...

  3. Dual Use Packaging Project

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA seeks down-weighted packaging compatible with microwave preparation and perhaps high hydrostatic pressure processing. New packaging must satisfy NASA's 3-year...

  4. Merganser Download Package

    Data.gov (United States)

    U.S. Environmental Protection Agency — This data download package contains an Esri 10.0 MXD, file geodatabase and copy of this FGDC metadata record. The data in this package are used in support of the...

  5. Comparative Packaging Study

    Science.gov (United States)

    Perchonok, Michele; Antonini, David

    2008-01-01

    This viewgraph presentation describes a comparative packaging study for use on long duration space missions. The topics include: 1) Purpose; 2) Deliverables; 3) Food Sample Selection; 4) Experimental Design Matrix; 5) Permeation Rate Comparison; and 6) Packaging Material Information.

  6. Openability of tamperproof packaging

    OpenAIRE

    Del Castillo C., A.; Wever, R; Buijs, P.J.; Stevels, A.

    2007-01-01

    Communication, product protection and presentation are three key aspects in the world of packaging nowadays. Due to a retail landscape consisting of large stores, displaying packed products on the shelves in self-service environments, these aspects become increasingly important, not only for Fast Moving Consumer Goods, but for consumer durables as well. In the communication aspect, the package delivers a promise to the customer contained in the package, but the package itself is part of this ...

  7. Packaging Printing Today

    OpenAIRE

    Bolanča, Stanislav; Majnarić, Igor; Golubović, Kristijan

    2015-01-01

    Printing packaging covers today about 50% of all the printing products. Among the printing products there are printing on labels, printing on flexible packaging, printing on folding boxes, printing on the boxes of corrugated board, printing on glass packaging, synthetic and metal ones. The mentioned packaging are printed in flexo printing technique, offset printing technique, intaglio halftone process, silk – screen printing, ink ball printing, digital printing and hybrid printing process. T...

  8. Trends in Food Packaging.

    Science.gov (United States)

    Ott, Dana B.

    1988-01-01

    This article discusses developments in food packaging, processing, and preservation techniques in terms of packaging materials, technologies, consumer benefits, and current and potential food product applications. Covers implications due to consumer life-style changes, cost-effectiveness of packaging materials, and the ecological impact of…

  9. Central heating: package boilers

    Energy Technology Data Exchange (ETDEWEB)

    Farahan, E.

    1977-05-01

    Performance and cost data for electrical and fossil-fired package boilers currently available from manufacturers are provided. Performance characteristics investigated include: unit efficiency, rated capacity, and average expected lifetime of units. Costs are tabulated for equipment and installation of various package boilers. The information supplied in this report will simplify the process of selecting package boilers required for industrial, commercial, and residential applications.

  10. Nucleosome packaging and nucleosome positioning of genomic DNA

    OpenAIRE

    Lowary, P. T.; Widom, J

    1997-01-01

    The goals of this study were to assess the extent to which bulk genomic DNA sequences contribute to their own packaging in nucleosomes and to reveal the relationship between nucleosome packaging and positioning. Using a competitive nucleosome reconstitution assay, we found that at least 95% of bulk DNA sequences have an affinity for histone octamer in nucleosomes that is similar to that of randomly synthesized DNA; they contribute little to their own packaging at the level of individual nucle...

  11. Edible packaging materials.

    Science.gov (United States)

    Janjarasskul, Theeranun; Krochta, John M

    2010-01-01

    Research groups and the food and pharmaceutical industries recognize edible packaging as a useful alternative or addition to conventional packaging to reduce waste and to create novel applications for improving product stability, quality, safety, variety, and convenience for consumers. Recent studies have explored the ability of biopolymer-based food packaging materials to carry and control-release active compounds. As diverse edible packaging materials derived from various by-products or waste from food industry are being developed, the dry thermoplastic process is advancing rapidly as a feasible commercial edible packaging manufacturing process. The employment of nanocomposite concepts to edible packaging materials promises to improve barrier and mechanical properties and facilitate effective incorporation of bioactive ingredients and other designed functions. In addition to the need for a more fundamental understanding to enable design to desired specifications, edible packaging has to overcome challenges such as regulatory requirements, consumer acceptance, and scaling-up research concepts to commercial applications.

  12. Mechanisms of human immunodeficiency virus type 2 RNA packaging

    DEFF Research Database (Denmark)

    Ni, Na; Nikolaitchik, Olga A; Dilley, Kari A

    2011-01-01

    Human immunodeficiency virus type 2 (HIV-2) has been reported to have a distinct RNA packaging mechanism, referred to as cis packaging, in which Gag proteins package the RNA from which they were translated. We examined the progeny generated from dually infected cell lines that contain two HIV-2...... that specifically recognize stem-loop motifs in the viral genomes, an assay termed single virion analysis. These studies revealed that >90% of the HIV-2 particles contained viral RNAs and that RNAs derived from different viruses were copackaged frequently. Furthermore, the frequencies of heterozygous particles...... do not support the cis-packaging hypothesis but instead indicate that trans packaging is the major mechanism of HIV-2 RNA packaging. To further characterize the mechanisms of HIV-2 RNA packaging, we visualized HIV-2 RNA in individual particles by using fluorescent protein-tagged RNA-binding proteins...

  13. Gas turbine vane cooling air insert

    Energy Technology Data Exchange (ETDEWEB)

    North, W.E.; Hultgren, K.G.; Dishman, C.D.; Van Heusden, G.S.

    1992-09-08

    This patent describes a gas turbine. It comprises turbine vanes, each of the vanes supplied with cooling air and having: an airfoil portion forming a first cavity having an insert disposed therein for directing the flow of the cooling air, the insert having first and second insert ends; a shroud portion from which the airfoil portion extends, the insert attached to the shroud portion at the first insert end; an insert extension extending through a portion of the insert and extending beyond the first insert end, the insert extension and the insert forming an annular gap therebetween separating the insert from the insert extension; a plate covering at least a portion of the shroud, the plate having a first hole formed therein through which the insert extension extends; and at least a first seal extending between the insert extension and the insert, and sealing the annular gap therebetween. This patent also describes a method of making a gas turbine. It comprises welding a first tubular insert adjacent its first end to a vane outer shroud; partially inserting a second tubular insert into the first tubular member and attaching the second tubular insert thereto; placing a plate having a hole formed therein on the outer shroud so that the hole surrounds the second tubular insert; and attaching the second tubular insert to the plate by placing a first seal between the first and second tubular inserts and attaching the first seal to each of the first and second tubular inserts, and placing a second seal between the second tubular insert and the plate and welding the second seal to the second tubular insert and the plate.

  14. Packaging for Sustainability

    CERN Document Server

    Lewis, Helen; Fitzpatrick, Leanne

    2012-01-01

    The packaging industry is under pressure from regulators, customers and other stakeholders to improve packaging’s sustainability by reducing its environmental and societal impacts. This is a considerable challenge because of the complex interactions between products and their packaging, and the many roles that packaging plays in the supply chain. Packaging for Sustainability is a concise and readable handbook for practitioners who are trying to implement sustainability strategies for packaging. Industry case studies are used throughout the book to illustrate possible applications and scenarios. Packaging for Sustainability draws on the expertise of researchers and industry practitioners to provide information on business benefits, environmental issues and priorities, environmental evaluation tools, design for environment, marketing strategies, and challenges for the future.

  15. [Intracavitary electrocardiogram during the insertion of peripherally inserted central catheters].

    Science.gov (United States)

    Ortiz-Miluy, Gloria; Sánchez-Guerra, Carmen

    2013-01-01

    To evaluate the applicability, feasibility and accuracy of the IC-ECG with column of saline technique for verifying the final tip position of peripherally inserted central catheters (PICC) by specialist nurses. A total of 99 consecutive PICC were inserted. Patients with no superficial ECG P wave, atrial fibrillation, or a pacemaker were excluded. The IC-ECG technique was performed on 84 patients. A chest x-ray was performed after insertion in all cases, in order to compare images with IC-ECG. The technique showed an applicability of 84.4%, an feasibility of 88%, and an accuracy of 87.8%. The IC-ECG technique for verification of catheter PICC tip locations with column of saline is easy to apply, is cost-effective, is achievable by nurses, and does not involve any risk for patients. The technique involves a learning curve, and it must be performed by qualified health care professionals. The technique is performed during the insertion of the catheter, so verification of the tip is made in situ. It reduces future re-insertions due to wrong positioning of the tip. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  16. Millimetre-wave MMIC packaging compatible with surface-mount technology (SMT)

    OpenAIRE

    Galière, J; Valard, J.L.; Estèbe, E.

    2004-01-01

    This paper presents an interconnect and packaging solution for millimetre-wave MMIC, based on collective wiring and surface mount technologies. The designed structure consists of an SMT CSP (Chip Scale Package) mounted on printed circuit board (PCB). This packaging concept has been applied to a millimetre-wave LNA and has been measured up to 60 GHz, exhibiting results close to bare die measurements (insertion loss per millimetre-wave transition lower than 0.5dB) and dem...

  17. Gene Insertion Patterns and Sites

    Science.gov (United States)

    Vain, Philippe; Thole, Vera

    During the past 25 years, the molecular analysis of transgene insertion patterns and sites in plants has greatly contributed to our understanding of the mechanisms underlying transgene integration, expression, and stability in the nuclear genome. Molecular characterization is also an essential step in the safety assessment of genetically modified crops. This chapter describes the standard experimental procedures used to analyze transgene insertion patterns and loci in cereals and grasses transformed using Agrobacterium tumefaciens or direct transfer of DNA. Methods and protocols enabling the determination of the number and configuration of transgenic loci via a combination of inheritance studies, polymerase chain reaction, and Southern analyses are presented. The complete characterization of transgenic inserts in plants is, however, a holistic process relying on a wide variety of experimental approaches. In this chapter, these additional approaches are not detailed but references to relevant bibliographic records are provided.

  18. WASTE PACKAGE TRANSPORTER DESIGN

    Energy Technology Data Exchange (ETDEWEB)

    D.C. Weddle; R. Novotny; J. Cron

    1998-09-23

    The purpose of this Design Analysis is to develop preliminary design of the waste package transporter used for waste package (WP) transport and related functions in the subsurface repository. This analysis refines the conceptual design that was started in Phase I of the Viability Assessment. This analysis supports the development of a reliable emplacement concept and a retrieval concept for license application design. The scope of this analysis includes the following activities: (1) Assess features of the transporter design and evaluate alternative design solutions for mechanical components. (2) Develop mechanical equipment details for the transporter. (3) Prepare a preliminary structural evaluation for the transporter. (4) Identify and recommend the equipment design for waste package transport and related functions. (5) Investigate transport equipment interface tolerances. This analysis supports the development of the waste package transporter for the transport, emplacement, and retrieval of packaged radioactive waste forms in the subsurface repository. Once the waste containers are closed and accepted, the packaged radioactive waste forms are termed waste packages (WP). This terminology was finalized as this analysis neared completion; therefore, the term disposal container is used in several references (i.e., the System Description Document (SDD)) (Ref. 5.6). In this analysis and the applicable reference documents, the term ''disposal container'' is synonymous with ''waste package''.

  19. User friendly packaging

    DEFF Research Database (Denmark)

    Geert Jensen, Birgitte

    2010-01-01

    “User-friendly Packaging” aims to create a platform for developing more user-friendly packaging. One intended outcome of the project is a guideline that industry can use in development efforts. The project also points the way for more extended collaboration between companies and design researchers. How...... can design research help industry in packaging innovation?...

  20. The BINSYN Program Package

    Directory of Open Access Journals (Sweden)

    Albert P. Linnell

    2012-06-01

    Full Text Available The BINSYN program package, recently expanded to calculate synthetic spectra of cataclysmic variables, is being further extended to include synthetic photometry of ordinary binary stars in addition to binary stars with optically thick accretion disks. The package includes a capability for differentials correction optimization of eclipsing binary systems using synthetic photometry.

  1. 21 CFR 864.7375 - Glutathione reductase assay.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Glutathione reductase assay. 864.7375 Section 864...) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864.7375 Glutathione reductase assay. (a) Identification. A glutathione reductase assay is a device used to determine the...

  2. New Finsler package

    Science.gov (United States)

    Youssef, Nabil L.; Elgendi, S. G.

    2014-03-01

    The book “Handbook of Finsler geometry” has been included with a CD containing an elegant Maple package, FINSLER, for calculations in Finsler geometry. Using this package, an example concerning a Finsler generalization of Einstein’s vacuum field equations was treated. In this example, the calculation of the components of the hv-curvature of Cartan connection leads to wrong expressions. On the other hand, the FINSLER package works only in dimension four. We introduce a new Finsler package in which we fix the two problems and solve them. Moreover, we extend this package to compute not only the geometric objects associated with Cartan connection but also those associated with Berwald, Chern and Hashiguchi connections in any dimension. These improvements have been illustrated by a concrete example. Furthermore, the problem of simplifying tensor expressions is treated. This paper is intended to make calculations in Finsler geometry more easier and simpler.

  3. Concepts for stereoselective acrylate insertion

    KAUST Repository

    Neuwald, Boris

    2013-01-23

    Various phosphinesulfonato ligands and the corresponding palladium complexes [{((PaO)PdMeCl)-μ-M}n] ([{( X1-Cl)-μ-M}n], (PaO) = κ2- P,O-Ar2PC6H4SO2O) with symmetric (Ar = 2-MeOC6H4, 2-CF3C6H4, 2,6-(MeO)2C6H3, 2,6-(iPrO)2C 6H3, 2-(2′,6′-(MeO)2C 6H3)C6H4) and asymmetric substituted phosphorus atoms (Ar1 = 2,6-(MeO)2C6H 3, Ar2 = 2′-(2,6-(MeO)2C 6H3)C6H4; Ar1 = 2,6-(MeO)2C6H3, Ar2 = 2-cHexOC 6H4) were synthesized. Analyses of molecular motions and dynamics by variable temperature NMR studies and line shape analysis were performed for the free ligands and the complexes. The highest barriers of ΔGa = 44-64 kJ/mol were assigned to an aryl rotation process, and the flexibility of the ligand framework was found to be a key obstacle to a more effective stereocontrol. An increase of steric bulk at the aryl substituents raises the motional barriers but diminishes insertion rates and regioselectivity. The stereoselectivity of the first and the second methyl acrylate (MA) insertion into the Pd-Me bond of in situ generated complexes X1 was investigated by NMR and DFT methods. The substitution pattern of the ligand clearly affects the first MA insertion, resulting in a stereoselectivity of up to 6:1 for complexes with an asymmetric substituted phosphorus. In the consecutive insertion, the stereoselectivity is diminished in all cases. DFT analysis of the corresponding insertion transition states revealed that a selectivity for the first insertion with asymmetric (P aO) complexes is diminished in the consecutive insertions due to uncooperatively working enantiomorphic and chain end stereocontrol. From these observations, further concepts are developed. © 2012 American Chemical Society.

  4. Packaging Printing Today

    Directory of Open Access Journals (Sweden)

    Stanislav Bolanča

    2015-12-01

    Full Text Available Printing packaging covers today about 50% of all the printing products. Among the printing products there are printing on labels, printing on flexible packaging, printing on folding boxes, printing on the boxes of corrugated board, printing on glass packaging, synthetic and metal ones. The mentioned packaging are printed in flexo printing technique, offset printing technique, intaglio halftone process, silk – screen printing, ink ball printing, digital printing and hybrid printing process. The possibilities of particular printing techniques for optimal production of the determined packaging were studied in the paper. The problem was viewed from the technological and economical aspect. The possible printing quality and the time necessary for the printing realization were taken as key parameters. An important segment of the production and the way of life is alocation value and it had also found its place in this paper. The events in the field of packaging printing in the whole world were analyzed. The trends of technique developments and the printing technology for packaging printing in near future were also discussed.

  5. Consumer response to packaging design

    NARCIS (Netherlands)

    Steenis, Nigel D.; Herpen, van Erica; Lans, van der Ivo A.; Ligthart, Tom N.; Trijp, van Hans C.M.

    2017-01-01

    Building on theories of cue utilization, this paper investigates whether and how packaging sustainability influences consumer perceptions, inferences and attitudes towards packaged products. A framework is tested in an empirical study among 249 students using soup products varying in packaging

  6. Hermeticity of electronic packages

    CERN Document Server

    Greenhouse, Hal; Romenesco, Bruce

    2011-01-01

    This is a book about the integrity of sealed packages to resist foreign gases and liquids penetrating the seal or an opening (crack) in the packageùespecially critical to the reliability and longevity of electronics. The author explains how to predict the reliability and the longevity of the packages based on leak rate measurements and the assumptions of impurities. Non-specialists in particular will benefit from the author's long involvement in the technology. Hermeticity is a subject that demands practical experience, and solving one problem does not necessarily give one the background to so

  7. Hermeticity of electronic packages

    CERN Document Server

    Greenhouse, Hal

    2000-01-01

    This is a book about the integrity of sealed packages to resist foreign gases and liquids penetrating the seal or an opening (crack) in the package-especially critical to the reliability and longevity of electronics. The author explains how to predict the reliability and the longevity of the packages based on leak rate measurements and the assumptions of impurities. Non-specialists in particular will benefit from the author's long involvement in the technology. Hermeticity is a subject that demands practical experience, and solving one problem does not necessarily give one the background to so

  8. White LED with High Package Extraction Efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Yi Zheng; Matthew Stough

    2008-09-30

    generated in the package may cause a deterioration of encapsulant materials, affecting the performance of both the LED die and phosphor, leading to a decrease in the luminous efficacy over lifetime. Recent studies from research groups at Rensselaer Polytechnic Institute found that, under the condition to obtain a white light, about 40% of the light is transmitted outward of the phosphor layer and 60% of the light is reflected inward.1,2 It is claimed that using scattered photon extraction (SPE) technique, luminous efficacy is increased by 60%. In this project, a transparent/translucent monolithic phosphor was used to replace the powdered phosphor layer. In the normal pcLED package, the powdered phosphor is mixed with silicone either to be deposited on the top of LED die forming a chip level conversion (CLC) white LED or to be casted in the package forming a volume conversion white LED. In the monolithic phosphors there are no phosphor powder/silicone interfaces so it can reduce the light scattering caused by phosphor particles. Additionally, a multi-layer thin film selectively reflecting filter is inserted in the white LED package between the blue LED die and phosphor layer. It will selectively transmit the blue light from the LED die and reflect the phosphor's yellow inward emission outward. The two technologies try to recover backward light to the outward direction in the pcLED package thereby improving the package extraction efficiency.

  9. Materials for advanced packaging

    CERN Document Server

    Wong, CP

    2017-01-01

    This second edition continues to be the most comprehensive review on the developments in advanced electronic packaging technologies, with a focus on materials and processing. Recognized experts in the field contribute to 22 updated and new chapters that provide comprehensive coverage on various 3D package architectures, novel bonding and joining techniques, wire bonding, wafer thinning techniques, organic substrates, and novel approaches to make electrical interconnects between integrated circuit and substrates. Various chapters also address advances in several key packaging materials, including: Lead-free solders Flip chip underfills Epoxy molding compounds Conductive adhesives Die attach adhesives/films Thermal interface materials (TIMS) Materials for fabricating embedded passives including capacitors, inductors, and resistors Materials and processing aspects on wafer-level chip scale package (CSP) and MicroElectroMechanical system (MEMS) Contributors also review new and emerging technologies such as Light ...

  10. Orbital heat rate package

    Science.gov (United States)

    Lovin, J. K.; Spradley, L. W.

    1979-01-01

    Package consisting of three separate programs used to accurately predict temperature distribution of spacecraft in planetary orbit is invaluable tool for design and analysis of other structures that must function in complex thermal environment.

  11. FLEXIBLE FOOD PACKAGING LABORATORY

    Data.gov (United States)

    Federal Laboratory Consortium — This laboratory contains equipment to fabricate and test prototype packages of many types and sizes (e.g., bags, pouches, trays, cartons, etc.). This equipment can...

  12. Packaging for Posterity.

    Science.gov (United States)

    Sias, Jim

    1990-01-01

    A project in which students designed environmentally responsible food packaging is described. The problem definition; research on topics such as waste paper, plastic, metal, glass, incineration, recycling, and consumer preferences; and the presentation design are provided. (KR)

  13. Dual Use Packaging Project

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA calculation that over a kg of packaging waste are generated per day for a 6 member crew. This represents over 1.5 metric tons of waste during a Mars mission....

  14. Informative document packaging waste

    NARCIS (Netherlands)

    Joosten JM; Nagelhout D; Duvoort GL; Weerd M de

    1989-01-01

    This "informative document packaging waste" forms part of a series of "informative documents waste materials". These documents are conducted by RIVM on the instructions of the Direcotrate General for the Environment, Waste Materials Directorate, in behalf of the program of

  15. The ENSDF Java Package

    Science.gov (United States)

    Sonzogni, A. A.

    2005-05-01

    A package of computer codes has been developed to process and display nuclear structure and decay data stored in the ENSDF (Evaluated Nuclear Structure Data File) library. The codes were written in an object-oriented fashion using the java language. This allows for an easy implementation across multiple platforms as well as deployment on web pages. The structure of the different java classes that make up the package is discussed as well as several different implementations.

  16. CH Packaging Program Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Washington TRU Solutions LLC

    2002-03-04

    The purpose of this document is to provide the technical requirements for preparation for use, operation, inspection, and maintenance of a Transuranic Package Transporter Model II (TRUPACT-II), a HalfPACT Shipping Package, and directly related components. This document complies with the minimum requirements as specified in TRUPACT-II Safety Analysis Report for Packaging (SARP), HalfPACT SARP, and Nuclear Regulatory Commission (NRC) Certificates of Compliance (C of C) 9218 and 9279, respectively. In the event there is a conflict between this document and the SARP or C of C, the SARP and/or C of C shall govern. C of Cs state: ''each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the application.'' They further state: ''each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application.'' Chapter 9.0 of the SAR P charges the WIPP Management and Operation (M&O) contractor with assuring packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with 10 CFR 71.11. Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the Carlsbad Field Office (CBFO) shall be notified immediately. CBFO will evaluate the issue and notify the NRC if required. This document details the instructions to be followed to operate, maintain, and test the TRUPACT-II and HalfPACT packaging. The intent of these instructions is to standardize these operations. All users will follow these instructions or equivalent instructions that assure operations are safe and meet the requirements of the SARPs.

  17. CH Packaging Program Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Washington TRU Solutions LLC

    2003-04-30

    The purpose of this document is to provide the technical requirements for preparation for use, operation, inspection, and maintenance of a Transuranic Package Transporter Model II (TRUPACT-II), a HalfPACT shipping package, and directly related components. This document complies with the minimum requirements as specified in the TRUPACT-II Safety Analysis Report for Packaging (SARP), HalfPACT SARP, and Nuclear Regulatory Commission (NRC) Certificates of Compliance (C of C) 9218 and 9279, respectively. In the event of a conflict between this document and the SARP or C of C, the C of C shall govern. The C of Cs state: ''each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the application.'' They further state: ''each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application.'' Chapter 9.0 of the SARP charges the WIPP management and operating (M&O) contractor with assuring packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with 10 CFR 71.11. Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the Carlsbad Field Office (CBFO) shall be notified immediately. CBFO will evaluate the issue and notify the NRC if required. This document provides the instructions to be followed to operate, maintain, and test the TRUPACT-II and HalfPACT packaging. The intent of these instructions is to standardize operations. All users will follow these instructions or equivalent instructions that assure operations are safe and meet the requirements of the SARPs.

  18. The first LHC insertion quadrupole

    CERN Multimedia

    2004-01-01

    An important milestone was reached in December 2003 at the CERN Magnet Assembly Facility. The team from the Accelerator Technology - Magnet and Electrical Systems group, AT-MEL, completed the first special superconducting quadrupole for the LHC insertions which house the experiments and major collider systems. The magnet is 8 metres long and contains two matching quadrupole magnets and an orbit corrector, a dipole magnet, used to correct errors in quadrupole alignment. All were tested in liquid helium and reached the ultimate performance criteria required for the LHC. After insertion in the cryostat, the superconducting magnet will be installed as the Q9 quadrupole in sector 7-8, the first sector of the LHC to be put in place in 2004. Members of the quadrupole team, from the AT-MEL group, gathered around the Q9 quadrupole at its inauguration on 12 December 2003 in building 181.

  19. RH Packaging Program Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Washington TRU Solutions LLC

    2008-01-12

    The purpose of this program guidance document is to provide the technical requirements for use, operation, inspection, and maintenance of the RH-TRU 72-B Waste Shipping Package (also known as the "RH-TRU 72-B cask") and directly related components. This document complies with the requirements as specified in the RH-TRU 72-B Safety Analysis Report for Packaging (SARP), and Nuclear Regulatory Commission (NRC) Certificate of Compliance (C of C) 9212. If there is a conflict between this document and the SARP and/or C of C, the C of C shall govern. The C of C states: "...each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the application." It further states: "...each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application." Chapter 9.0 of the SARP tasks the Waste Isolation Pilot Plant (WIPP) Management and Operating (M&O) Contractor with assuring the packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with Title 10 Code of Federal Regulations (CFR) §71.8, "Deliberate Misconduct." Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the U.S. Department of Energy (DOE) Carlsbad Field Office (CBFO) shall be notified immediately. The CBFO will evaluate the issue and notify the NRC if required.In accordance with 10 CFR Part 71, "Packaging and Transportation of Radioactive Material," certificate holders, packaging users, and contractors or subcontractors who use, design, fabricate, test, maintain, or modify the packaging shall post copies of (1) 10 CFR Part 21, "Reporting of Defects and Noncompliance," regulations, (2) Section 206 of the Energy Reorganization Act of 1974, and (3) NRC Form 3, Notice to Employees. These documents must be posted in a

  20. CH Packaging Program Guidance

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2009-06-01

    The purpose of this document is to provide the technical requirements for preparation for use, operation, inspection, and maintenance of a Transuranic Package Transporter Model II (TRUPACT-II), a HalfPACT shipping package, and directly related components. This document complies with the minimum requirements as specified in the TRUPACT-II Safety Analysis Report for Packaging (SARP), HalfPACT SARP, and U.S. Nuclear Regulatory Commission (NRC) Certificates of Compliance (C of C) 9218 and 9279, respectively. In the event of a conflict between this document and the SARP or C of C, the C of C shall govern. The C of Cs state: "each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the application." They further state: "each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application." Chapter 9.0 of the SARP charges the U.S. Department of Energy (DOE) or the Waste Isolation Pilot Plant (WIPP) management and operating (M&O) contractor with assuring packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with Title 10 Code of Federal Regulations (CFR) §71.8. Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the Carlsbad Field Office (CBFO) shall be notified immediately. The CBFO will evaluate the issue and notify the NRC if required. In accordance with 10 CFR Part 71, certificate holders, packaging users, and contractors or subcontractors who use, design, fabricate, test, maintain, or modify the packaging shall post copies of (1) 10 CFR Part 21 regulations, (2) Section 206 of the Energy Reorganization Act of 1974, and (3) NRC Form 3, Notice to Employees. These documents must be posted in a conspicuous location where the activities subject to these regulations are

  1. CH Packaging Program Guidance

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2008-09-11

    The purpose of this document is to provide the technical requirements for preparation for use, operation, inspection, and maintenance of a Transuranic Package Transporter Model II (TRUPACT-II), a HalfPACT shipping package, and directly related components. This document complies with the minimum requirements as specified in the TRUPACT-II Safety Analysis Report for Packaging (SARP), HalfPACT SARP, and U.S. Nuclear Regulatory Commission (NRC) Certificates of Compliance (C of C) 9218 and 9279, respectively. In the event of a conflict between this document and the SARP or C of C, the C of C shall govern. The C of Cs state: "each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the pplication." They further state: "each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application." Chapter 9.0 of the SARP charges the U.S. Department of Energy (DOE) or the Waste Isolation Pilot Plant (WIPP) management and operating (M&O) contractor with assuring packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with Title 10 Code of Federal Regulations (CFR) §71.8. Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the Carlsbad Field Office (CBFO) shall be notified immediately. The CBFO will evaluate the issue and notify the NRC if required. In accordance with 10 CFR Part 71, certificate holders, packaging users, and contractors or subcontractors who use, design, fabricate, test, maintain, or modify the packaging shall post copies of (1) 10 CFR Part 21 regulations, (2) Section 206 of the Energy Reorganization Act of 1974, and (3) NRC Form 3, Notice to Employees. These documents must be posted in a conspicuous location where the activities subject to these regulations are

  2. RH Packaging Program Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Washington TRU Solutions LLC

    2006-11-07

    The purpose of this program guidance document is to provide the technical requirements for use, operation, inspection, and maintenance of the RH-TRU 72-B Waste Shipping Package and directly related components. This document complies with the requirements as specified in the RH-TRU 72-B Safety Analysis Report for Packaging (SARP), and Nuclear Regulatory Commission (NRC) Certificate of Compliance (C of C) 9212. If there is a conflict between this document and the SARP and/or C of C, the C of C shall govern. The C of C states: "...each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the application." It further states: "...each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application." Chapter 9.0 of the SARP tasks the Waste Isolation Pilot Plant (WIPP) Management and Operating (M&O) Contractor with assuring the packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with 10 Code of Federal Regulations (CFR) §71.8, "Deliberate Misconduct." Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the U.S. Department of Energy (DOE) Carlsbad Field Office (CBFO) shall be notified immediately. CBFO will evaluate the issue and notify the NRC if required. In accordance with 10 CFR Part 71, "Packaging and Transportation of Radioactive Material," certificate holders, packaging users, and contractors or subcontractors who use, design, fabricate, test, maintain, or modify the packaging shall post copies of (1) 10 CFR Part 21, "Reporting of Defects and Noncompliance," regulations, (2) Section 206 of the Energy Reorganization Act of 1974, and (3) NRC Form 3, Notice to Employees. These documents must be posted in a conspicuous location where the activities subject to

  3. CH Packaging Program Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Washington TRU Solutions LLC

    2005-02-28

    The purpose of this document is to provide the technical requirements for preparation for use, operation, inspection, and maintenance of a Transuranic Package Transporter Model II (TRUPACT-II), a HalfPACT shipping package, and directly related components. This document complies with the minimum requirements as specified in the TRUPACT-II Safety Analysis Report for Packaging (SARP), HalfPACT SARP, and U.S. Nuclear Regulatory Commission (NRC) Certificates of Compliance (C of C) 9218 and 9279, respectively. In the event of a conflict between this document and the SARP or C of C, the C of C shall govern. The C of Cs state: "each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the application." They further state: "each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application." Chapter 9.0 of the SARP charges the Waste Isolation Pilot Plant (WIPP) management and operating (M&O) contractor with assuring packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with Title 10 Code of Federal Regulations (CFR) §71.8. Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the Carlsbad Field Office (CBFO) shall be notified immediately. The CBFO will evaluate the issue and notify the NRC if required.

  4. Food Packaging Materials

    Science.gov (United States)

    1978-01-01

    The photos show a few of the food products packaged in Alure, a metallized plastic material developed and manufactured by St. Regis Paper Company's Flexible Packaging Division, Dallas, Texas. The material incorporates a metallized film originally developed for space applications. Among the suppliers of the film to St. Regis is King-Seeley Thermos Company, Winchester, Ma'ssachusetts. Initially used by NASA as a signal-bouncing reflective coating for the Echo 1 communications satellite, the film was developed by a company later absorbed by King-Seeley. The metallized film was also used as insulating material for components of a number of other spacecraft. St. Regis developed Alure to meet a multiple packaging material need: good eye appeal, product protection for long periods and the ability to be used successfully on a wide variety of food packaging equipment. When the cost of aluminum foil skyrocketed, packagers sought substitute metallized materials but experiments with a number of them uncovered problems; some were too expensive, some did not adequately protect the product, some were difficult for the machinery to handle. Alure offers a solution. St. Regis created Alure by sandwiching the metallized film between layers of plastics. The resulting laminated metallized material has the superior eye appeal of foil but is less expensive and more easily machined. Alure effectively blocks out light, moisture and oxygen and therefore gives the packaged food long shelf life. A major packaging firm conducted its own tests of the material and confirmed the advantages of machinability and shelf life, adding that it runs faster on machines than materials used in the past and it decreases product waste; the net effect is increased productivity.

  5. Dual Use of Packaging on the Moon: Logistics-2-Living

    Science.gov (United States)

    Howe, A. Scott; Howard, Robert

    2010-01-01

    This paper describes a modular packaging system for logistics that can be reconfigured into internal outfitting for a lunar outpost, including desks, chairs, partitions, cabinets, and radiation shielding. Logistics include clothes, equipment, food, and other consumables needed to sustain the crew for the duration of the mission. A significant mass penalty is required for the packaging and handling of logistics for re-supply of short to long-term space missions that must be brought out of the gravity well on a launch vehicle. Once the supplies have been exhausted, the packaging material is typically of no further use and is discarded. If a scheme can be developed that reuses the logistics packaging, the mass penalty can be reduced. In this research, a modular packaging system has been devised as a kit-of-parts that can be used for both handling logistics supplies, and then reconfigured into desks, chairs, partitions, cabinets, and radiation shielding. The system is derived from a standard International Space Station (ISS)-type Cargo Transfer Bag (CTB), using soft, unfoldable box-like containers with stiff metal inserts. The empty hydrogen-impregnated CTBs can be used as-is for cabinets, opened up for use as partitions, or draped over the habitat as layers of radiation shielding. Stiff metal inserts can be reconfigured into desks and other useful outfitting.

  6. Food packages for Space Shuttle

    Science.gov (United States)

    Fohey, M. F.; Sauer, R. L.; Westover, J. B.; Rockafeller, E. F.

    1978-01-01

    The paper reviews food packaging techniques used in space flight missions and describes the system developed for the Space Shuttle. Attention is directed to bite-size food cubes used in Gemini, Gemini rehydratable food packages, Apollo spoon-bowl rehydratable packages, thermostabilized flex pouch for Apollo, tear-top commercial food cans used in Skylab, polyethylene beverage containers, Skylab rehydratable food package, Space Shuttle food package configuration, duck-bill septum rehydration device, and a drinking/dispensing nozzle for Space Shuttle liquids. Constraints and testing of packaging is considered, a comparison of food package materials is presented, and typical Shuttle foods and beverages are listed.

  7. Vegetable crops deformation assays for package height definition: a new approach Ensaios de deformação mecânica de hortaliças para a definição da altura de embalagens: um novo enfoque

    Directory of Open Access Journals (Sweden)

    Rita de Fátima Alves Luengo

    2008-02-01

    Full Text Available In the present work one determined the threshold pile height below which cracking and other deformations do not occur in products with low apparent density such as lettuce, collard greens and bell pepper. Initially the threshold pile height was sought applying decreasing compression stresses equivalent to pile loads of 160, 120 and 80 cm, with four replicates in four hour assays. The safe threshold pile height which protects the products against cracking rupture in these three commodities were of 80 cm. In a complementary study, plastic and elastic deformations induced by this safe pile threshold height were measured. The irreversible deformation, plastic deformation component, were lower in bell pepper (3.8 %, medium in lettuce (4.23 % and had the higher values in collard greens (10.2 %. The reversible deformations, the elastic component, was also the lower in bell pepper (4.14 %, medium in lettuce (7.41 % and the higher in collard greens (8.17 %. Considering these modest plastic deformations, the safe pile threshold heights were accepted and the safe package heights were defined as the pile threshold height multiplied by a factor of 0.5. This safety factor incorporates protection against accelerations of impact and vibration which occur during handling and transportation, as it was previously used for the development of packages for compact fruits and vegetables with higher apparent density. According to the method used the maximum package height should be of 40 cm, for the low density model products of this study.Neste trabalho, determinou-se a altura limiar de pilha, altura abaixo da qual não ocorrem rachaduras e outras deformações que são prejudiciais em alface, couve e pimentão, três produtos de baixa densidade aparente. Primeiramente, determinou-se a altura da pilha abaixo da qual não ocorrem rachaduras. Para isso os tratamentos foram compressões decrescentes. Essas compressões decrescentes foram 160, 120 e 80 cm de pilha

  8. CH Packaging Program Guidance

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2007-12-13

    The purpose of this document is to provide the technical requirements for preparation for use, operation, inspection, and maintenance of a Transuranic Package Transporter Model II (TRUPACT-II), a HalfPACT shipping package, and directly related components. This document complies with the minimum requirements as specified in the TRUPACT-II Safety Analysis Report for Packaging (SARP), HalfPACT SARP, and U.S. Nuclear Regulatory Commission (NRC) Certificates of Compliance (C of C) 9218 and 9279, respectively. In the event of a conflict between this document and the SARP or C of C, the C of C shall govern. The C of Cs state: "each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the application." They further state: "each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application." Chapter 9.0 of the SARP charges the U.S. Department of Energy (DOE) or the Waste Isolation Pilot Plant (WIPP) management and operating (M&O) contractor with assuring packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with Title 10 Code of Federal Regulations (CFR) §71.8. Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the Carlsbad Field Office (CBFO) shall be notified immediately. The CBFO will evaluate the issue and notify the NRC if required.In accordance with 10 CFR Part 71, certificate holders, packaging users, and contractors or subcontractors who use, design, fabricate, test, maintain, or modify the packaging shall post copies of (1) 10 CFR Part 21 regulations, (2) Section 206 of the Energy Reorganization Act of 1974, and (3) NRC Form 3, Notice to Employees. These documents must be posted in a conspicuous location where the activities subject to these regulations are

  9. CH Packaging Program Guidance

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2006-04-25

    The purpose of this document is to provide the technical requirements for preparation for use, operation, inspection, and maintenance of a Transuranic Package TransporterModel II (TRUPACT-II), a HalfPACT shipping package, and directly related components. This document complies with the minimum requirements as specified in the TRUPACT-II Safety Analysis Report for Packaging (SARP), HalfPACT SARP, and U.S. Nuclear Regulatory Commission (NRC) Certificates of Compliance (C of C) 9218 and 9279, respectively. In the event of a conflict between this document and the SARP or C of C, the C of C shall govern. The C of Cs state: "each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the application." They further state: "each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application." Chapter 9.0 of the SARP charges the U.S. Department of Energy (DOE) or the Waste Isolation Pilot Plant| (WIPP) management and operating (M&O) contractor with assuring packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with Title 10 Code of Federal Regulations(CFR) §71.8. Any time a user suspects or has indications that the conditions ofapproval in the C of C were not met, the Carlsbad Field Office (CBFO) shall be notified immediately. The CBFO will evaluate the issue and notify the NRC if required.In accordance with 10 CFR Part 71, certificate holders, packaging users, and contractors or subcontractors who use, design, fabricate, test, maintain, or modify the packaging shall post copies of (1) 10 CFR Part 21 regulations, (2) Section 206 of the Energy Reorganization Act of 1974, and (3) NRC Form 3, Notice to Employees. These documents must be posted in a conspicuous location where the activities subject to these regulations are

  10. A Review of Patents for the Smart Packaging of Meat and Muscle-based Food Products.

    Science.gov (United States)

    Holman, Benjamin; Kerry, Joseph P; Hopkins, David L

    2017-10-31

    Meat packaging once acted primarily as an inert barrier to protect its contents against contamination and this function has shifted. Packaging now includes complementary functions that improve product quality, longevity and customer/retail appeal. The devices and methods applied to achieve these functions may be categorised as smart packaging, which includes intelligent packaging, devised to monitor and communicate packaged content status, and active packaging, to provide passive adjustment of in-pack conditions from its interactions with the packaged meat. Smart packaging examples already available from recent patents include antimicrobial and antioxidant packaging coatings and inserts; sensors or indicators that identify spoilage and freshness; functional engineering customisations; improvements to packaging integrity; leak or tamper detectors; and, environmentally sustainable options. Together, these inventions respond to industry and customer demands for meat packaging and are therefore the focus of this review, in which we discuss their applications and limitations in meat packaging. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  11. Single-molecule packaging initiation in real time by a viral DNA packaging machine from bacteriophage T4

    Science.gov (United States)

    Vafabakhsh, Reza; Kondabagil, Kiran; Earnest, Tyler; Lee, Kyung Suk; Zhang, Zhihong; Dai, Li; Dahmen, Karin A.; Rao, Venigalla B.; Ha, Taekjip

    2014-01-01

    Viral DNA packaging motors are among the most powerful molecular motors known. A variety of structural, biochemical, and single-molecule biophysical approaches have been used to understand their mechanochemistry. However, packaging initiation has been difficult to analyze because of its transient and highly dynamic nature. Here, we developed a single-molecule fluorescence assay that allowed visualization of packaging initiation and reinitiation in real time and quantification of motor assembly and initiation kinetics. We observed that a single bacteriophage T4 packaging machine can package multiple DNA molecules in bursts of activity separated by long pauses, suggesting that it switches between active and quiescent states. Multiple initiation pathways were discovered including, unexpectedly, direct DNA binding to the capsid portal followed by recruitment of motor subunits. Rapid succession of ATP hydrolysis was essential for efficient initiation. These observations have implications for the evolution of icosahedral viruses and regulation of virus assembly. PMID:25288726

  12. Future trends in electronic packaging

    Science.gov (United States)

    Elshabini, Aicha; Wang, Gangqiang; Barlow, Fred

    2006-03-01

    Electronic packaging is traditionally defined as the back-end process that transforms bare integrated circuits (IC) into functional products. As the IC feature size decreases and the size of silicon wafer increases, the cost per IC is reduced and the performance is enhanced. The future IC chips will be larger in size, have more input/output terminals (I/Os), and require higher power. In addition to the advancements in IC technology, electronic packaging is also driven by the market requirements for low cost, small size, and multi-functional electronic products. In response to these requirements, packaging related areas such as design, packaging architectures, materials, processes, and manufacturing equipment are all changing rapidly. Wafer-level packaging (WLP) offers the benefits of low cost and smallest size for single chip packages, since the package is done at wafer level other than individual die. After packages reach the horizontal limit of dimensions, 3D stacking solution provides more efficient packages through expanding packages in the vertical dimension. Functional integration is achieved with 3D stacking architectures. System in package (SiP), one of the solutions to system integration, incorporates electronics, non-electronic devices such as optical devices, biological devices, micro-electro-mechanical systems (MEMS), etc, and interconnection in a single package, to form smart structures or microsystems. MEMS devices require specialized packaging to serve new market applications. This paper and presentation describe the technology requirements and challenges of these advancing packaging areas. The potential solutions and future trends are presented.

  13. Evaluation ofrapid enzyme immunobinding assays for the detection ...

    African Journals Online (AJOL)

    and the Rapid HIV1/HIV2 AB (Clonatec, France) required reconstitution of reagents; once reconstituted, the specimen diluem and conjugate in the Clonatec kit were stable at 2 - 8°C for 'one month at the most'. (package insert). The kit contained 2 vials of lyophilised diluent and 2 vials of the lyophilised conjugate_ In the.

  14. Geothermal Greenhouse Information Package

    Energy Technology Data Exchange (ETDEWEB)

    Rafferty, K. [P.E.; Boyd, T. [ed.

    1997-01-01

    This package of information is intended to provide a foundation of background information for developers of geothermal greenhouses. The material is divided into seven sections covering such issues as crop culture and prices, operating costs for greenhouses, heating system design, vendors and a list of other sources of information.

  15. Aquaculture Information Package

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, T.; Rafferty, K. [editors

    1998-01-01

    This package of information is intended to provide background to developers of geothermal aquaculture projects. The material is divided into eight sections and includes information on market and price information for typical species, aquaculture water quality issues, typical species culture information, pond heat loss calculations, an aquaculture glossary, regional and university aquaculture offices and state aquaculture permit requirements.

  16. Waste disposal package

    Science.gov (United States)

    Smith, M.J.

    1985-06-19

    This is a claim for a waste disposal package including an inner or primary canister for containing hazardous and/or radioactive wastes. The primary canister is encapsulated by an outer or secondary barrier formed of a porous ceramic material to control ingress of water to the canister and the release rate of wastes upon breach on the canister. 4 figs.

  17. Openability of tamperproof packaging

    NARCIS (Netherlands)

    Del Castillo C., A.; Wever, R.; Buijs, P.J.; Stevels, A.

    2007-01-01

    Communication, product protection and presentation are three key aspects in the world of packaging nowadays. Due to a retail landscape consisting of large stores, displaying packed products on the shelves in self-service environments, these aspects become increasingly important, not only for Fast

  18. Radioactive waste disposal package

    Science.gov (United States)

    Lampe, Robert F.

    1986-11-04

    A radioactive waste disposal package comprising a canister for containing vitrified radioactive waste material and a sealed outer shell encapsulating the canister. A solid block of filler material is supported in said shell and convertible into a liquid state for flow into the space between the canister and outer shell and subsequently hardened to form a solid, impervious layer occupying such space.

  19. High Efficiency Integrated Package

    Energy Technology Data Exchange (ETDEWEB)

    Ibbetson, James

    2013-09-15

    Solid-state lighting based on LEDs has emerged as a superior alternative to inefficient conventional lighting, particularly incandescent. LED lighting can lead to 80 percent energy savings; can last 50,000 hours – 2-50 times longer than most bulbs; and contains no toxic lead or mercury. However, to enable mass adoption, particularly at the consumer level, the cost of LED luminaires must be reduced by an order of magnitude while achieving superior efficiency, light quality and lifetime. To become viable, energy-efficient replacement solutions must deliver system efficacies of ≥ 100 lumens per watt (LPW) with excellent color rendering (CRI > 85) at a cost that enables payback cycles of two years or less for commercial applications. This development will enable significant site energy savings as it targets commercial and retail lighting applications that are most sensitive to the lifetime operating costs with their extended operating hours per day. If costs are reduced substantially, dramatic energy savings can be realized by replacing incandescent lighting in the residential market as well. In light of these challenges, Cree proposed to develop a multi-chip integrated LED package with an output of > 1000 lumens of warm white light operating at an efficacy of at least 128 LPW with a CRI > 85. This product will serve as the light engine for replacement lamps and luminaires. At the end of the proposed program, this integrated package was to be used in a proof-of-concept lamp prototype to demonstrate the component’s viability in a common form factor. During this project Cree SBTC developed an efficient, compact warm-white LED package with an integrated remote color down-converter. Via a combination of intensive optical, electrical, and thermal optimization, a package design was obtained that met nearly all project goals. This package emitted 1295 lm under instant-on, room-temperature testing conditions, with an efficacy of 128.4 lm/W at a color temperature of ~2873

  20. An empirical study on the relationship of purchasing a chocolate based on its packaging

    Directory of Open Access Journals (Sweden)

    Yasaman Giyahi

    2012-04-01

    Full Text Available Chocolate is one of popular gifts among people in many societies. Packaging of such product plays an important role on marketing this item and the primary question of this survey is to determine the impact of packaging on better introducing a product. The inference statistical tests show that packaging is an important item in selection of chocolate as a gift. Percentage of chocolate is the most important information on packaging and color of packaging is of paramount significance when customers purchase chocolate for individuals with official relationship. In this paper, we present an empirical study to measure the effects of chocolates' packaging on purchasing them. The proposed study of this paper designs a questionnaire and distributes them among different people. The results are analyzed using some non-parametric tests and they are discussed. The preliminary results indicate that the number of purchased packages within a year, cost of purchasing chocolate within a year, type of relationship of recipients of chocolate as gift, gender of recipient of chocolate as gift, age group of recipient of gift, type of store, nationality of chocolate, significance of packaging in various price ranges, type of packaging, insertion of information on package and color of packaging, are important factors influencing people to buy more.

  1. In-Package Chemistry Abstraction

    Energy Technology Data Exchange (ETDEWEB)

    P.S. Domski

    2003-07-21

    The work associated with the development of this model report was performed in accordance with the requirements established in ''Technical Work Plan for Waste Form Degradation Modeling, Testing, and Analyses in Support of SR and LA'' (BSC 2002a). The in-package chemistry model and in-package chemistry model abstraction are developed to predict the bulk chemistry inside of a failed waste package and to provide simplified expressions of that chemistry. The purpose of this work is to provide the abstraction model to the Performance Assessment Project and the Waste Form Department for development of geochemical models of the waste package interior. The scope of this model report is to describe the development and validation of the in-package chemistry model and in-package chemistry model abstraction. The in-package chemistry model will consider chemical interactions of water with the waste package materials and the waste form for commercial spent nuclear fuel (CSNF) and codisposed high-level waste glass (HLWG) and N Reactor spent fuel (CDNR). The in-package chemistry model includes two sub-models, the first a water vapor condensation (WVC) model, where water enters a waste package as vapor and forms a film on the waste package components with subsequent film reactions with the waste package materials and waste form--this is a no-flow model, the reacted fluids do not exit the waste package via advection. The second sub-model of the in-package chemistry model is the seepage dripping model (SDM), where water, water that may have seeped into the repository from the surrounding rock, enters a failed waste package and reacts with the waste package components and waste form, and then exits the waste package with no accumulation of reacted water in the waste package. Both of the submodels of the in-package chemistry model are film models in contrast to past in-package chemistry models where all of the waste package pore space was filled with water. The

  2. Lakes Ecosystem Services Download Package

    Data.gov (United States)

    U.S. Environmental Protection Agency — This data download package contains Esri 10.0 MXDs, file geodatabases and copy of this FGDC metadata record. The data in this package are used in support of the Lake...

  3. Food packaging history and innovations.

    Science.gov (United States)

    Risch, Sara J

    2009-09-23

    Food packaging has evolved from simply a container to hold food to something today that can play an active role in food quality. Many packages are still simply containers, but they have properties that have been developed to protect the food. These include barriers to oxygen, moisture, and flavors. Active packaging, or that which plays an active role in food quality, includes some microwave packaging as well as packaging that has absorbers built in to remove oxygen from the atmosphere surrounding the product or to provide antimicrobials to the surface of the food. Packaging has allowed access to many foods year-round that otherwise could not be preserved. It is interesting to note that some packages have actually allowed the creation of new categories in the supermarket. Examples include microwave popcorn and fresh-cut produce, which owe their existence to the unique packaging that has been developed.

  4. Anticounterfeit packaging technologies

    Directory of Open Access Journals (Sweden)

    Ruchir Y Shah

    2010-01-01

    Full Text Available Packaging is the coordinated system that encloses and protects the dosage form. Counterfeit drugs are the major cause of morbidity, mortality, and failure of public interest in the healthcare system. High price and well-known brands make the pharma market most vulnerable, which accounts for top priority cardiovascular, obesity, and antihyperlipidemic drugs and drugs like sildenafil. Packaging includes overt and covert technologies like barcodes, holograms, sealing tapes, and radio frequency identification devices to preserve the integrity of the pharmaceutical product. But till date all the available techniques are synthetic and although provide considerable protection against counterfeiting, have certain limitations which can be overcome by the application of natural approaches and utilization of the principles of nanotechnology.

  5. RH Packaging Program Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Washington TRU Solutions, LLC

    2003-08-25

    The purpose of this program guidance document is to provide technical requirements for use, operation, inspection, and maintenance of the RH-TRU 72-B Waste Shipping Package and directly related components. This document complies with the requirements as specified in the RH-TRU 72-B Safety Analysis Report for Packaging (SARP), and Nuclear Regulatory Commission (NRC) Certificate of Compliance (C of C) 9212. If there is a conflict between this document and the SARP and/or C of C, the SARP and/or C of C shall govern. The C of C states: ''...each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, ''Operating Procedures,'' of the application.'' It further states: ''...each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, ''Acceptance Tests and Maintenance Program of the Application.'' Chapter 9.0 of the SARP tasks the Waste Isolation Pilot Plant (WIPP) Management and Operating (M&O) contractor with assuring the packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC approved, users need to be familiar with 10 CFR {section} 71.11, ''Deliberate Misconduct.'' Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the Carlsbad Field Office (CBFO) shall be notified immediately. CBFO will evaluate the issue and notify the NRC if required. This document details the instructions to be followed to operate, maintain, and test the RH-TRU 72-B packaging. This Program Guidance standardizes instructions for all users. Users shall follow these instructions. Following these instructions assures that operations are safe and meet the requirements of the SARP. This document is available on the Internet at: ttp://www.ws/library/t2omi/t2omi.htm. Users are responsible for ensuring they are using the current

  6. The Swarm Magnetometry Package

    DEFF Research Database (Denmark)

    Merayo, José M.G.; Jørgensen, John Leif; Friis-Christensen, Eigil

    2008-01-01

    The Swarm mission under the ESA's Living Planet Programme is planned for launch in 2010 and consists of a constellation of three satellites at LEO. The prime objective of Swarm is to measure the geomagnetic field with unprecedented accuracy in space and time. The magnetometry package consists of ...... of an extremely accurate and stable vector magnetometer, which is co-mounted in an optical bench together with a start tracker system to ensure mechanical stability of the measurements....

  7. Amdahl 470 Chip Package

    CERN Multimedia

    1975-01-01

    In the late 70s the larger IBM computers were water cooled. Amdahl, an IBM competitor, invented an air cooling technology for it's computers. His company worked hard, developing a computer that was faster and less expensive than the IBM System/360 mainframe computer systems. This object contains an actual Amdahl series 470 computer logic chip with an air cooling device mounted on top. The package leads and cooling tower are gold-plated.

  8. Aquaculture information package

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, T.; Rafferty, K.

    1998-08-01

    This package of information is intended to provide background information to developers of geothermal aquaculture projects. The material is divided into eight sections and includes information on market and price information for typical species, aquaculture water quality issues, typical species culture information, pond heat loss calculations, an aquaculture glossary, regional and university aquaculture offices and state aquaculture permit requirements. A bibliography containing 68 references is also included.

  9. Sequential cooling insert for turbine stator vane

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Russel B

    2017-04-04

    A sequential flow cooling insert for a turbine stator vane of a small gas turbine engine, where the impingement cooling insert is formed as a single piece from a metal additive manufacturing process such as 3D metal printing, and where the insert includes a plurality of rows of radial extending impingement cooling air holes alternating with rows of radial extending return air holes on a pressure side wall, and where the insert includes a plurality of rows of chordwise extending second impingement cooling air holes on a suction side wall. The insert includes alternating rows of radial extending cooling air supply channels and return air channels that form a series of impingement cooling on the pressure side followed by the suction side of the insert.

  10. A HTS dipole insert coil constructed

    CERN Document Server

    Ballarino, A; Rey, J M; Stenvall, A; Sorbi, M; Tixador, P

    2013-01-01

    This report is the deliverable report 7.4.1 “A HTS dipole insert coil constructed“. The report has three parts: “Design report for the HTS dipole insert”, “One insert pancake prototype coil constructed with the setup for a high field test”, and “All insert components ordered”. The three report parts show that, although the insert construction will be only completed by end 2013, all elements are present for a successful completion and that, given the important investments done by the participants, there is a full commitment of all of them to finish the project

  11. Packaging based on polymeric materials

    Directory of Open Access Journals (Sweden)

    Jovanović Slobodan M.

    2005-01-01

    Full Text Available In the past two years the consumption of common in the developed countries world wide (high tonnage polymers for packaging has approached a value of 50 wt.%. In the same period more than 50% of the packaging units on the world market were made of polymeric materials despite the fact that polymeric materials present 17 wt.% of all packaging materials. The basic properties of polymeric materials and their environmental and economical advantages, providing them such a position among packaging materials, are presented in this article. Recycling methods, as well as the development trends of polymeric packaging materials are also presented.

  12. Plutonium stabilization and packaging system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-05-01

    This document describes the functional design of the Plutonium Stabilization and Packaging System (Pu SPS). The objective of this system is to stabilize and package plutonium metals and oxides of greater than 50% wt, as well as other selected isotopes, in accordance with the requirements of the DOE standard for safe storage of these materials for 50 years. This system will support completion of stabilization and packaging campaigns of the inventory at a number of affected sites before the year 2002. The package will be standard for all sites and will provide a minimum of two uncontaminated, organics free confinement barriers for the packaged material.

  13. Genome-wide LORE1 retrotransposon mutagenesis and high-throughput insertion detection in Lotus japonicus

    DEFF Research Database (Denmark)

    Urbanski, Dorian Fabian; Malolepszy, Anna; Stougaard, Jens

    2012-01-01

    and insertion site identification. So far, only floral dip T-DNA transformation of Arabidopsis has produced independent germinal insertions, thereby allowing generation of mutant populations from seeds of single plants. In addition, advances in insertion detection have been hampered by a lack of protocols...... including software for automated data analysis, which take full advantage of high next-generation sequencing throughput. Here we address these challenges by developing the FSTpoolit protocol and software package and we demonstrate its efficacy by detecting 8,935 LORE1 insertions in 3,744 Lotus japonicus...

  14. Mother-baby package.

    Science.gov (United States)

    Tamburlini, G

    1995-07-01

    The World Health Organization (WHO) Maternal Health and Safe Motherhood Programme developed the Mother-Baby package to facilitate the development of national strategies and plans of action. It was presented at an international meeting in Geneva in April 1994. The goals of the package are by the year 2000 to reduce maternal mortality by half and perinatal and neonatal mortality by 30-40% of 1990 levels. The package comprises: 1) a section on the technical basis and underlying strategies, 2) a section describing intervention before and during pregnancy, and during and after delivery, and 3) detailed recommendations on operating the program. The underlying strategy aims to reduce the number of high-risk and unwanted pregnancies; the number of obstetric complications; and the case fatality rate in women with complications. Interventions are based on a fourfold approach of family planning, quality antenatal care, clean and safe delivery, and access to essential obstetric care for high-risk pregnancies and complications. The district health system is the basic unit for planning and implementing the interventions. Midwives who live in the community are best equipped to provide appropriate community-based care to pregnant women. Pregnancy and obstetric complications requiring surgery and anesthesia should be available in the district hospital with an adequate referral system. Upgrading the skills of traditional birth attendants is also essential. National authorities should undertake a series of steps to carry out the interventions. A basic infrastructure, the upgrading of peripheral facilities, the development of human resources for safe motherhood, the effective delegation of responsibility, information, education, and communication (IEC), the involvement of nongovernmental organizations and women's groups, and the monitoring of results are other important elements in carrying out the interventions.

  15. Packaging - Materials review

    Science.gov (United States)

    Herrmann, Matthias

    2014-06-01

    Nowadays, a large number of different electrochemical energy storage systems are known. In the last two decades the development was strongly driven by a continuously growing market of portable electronic devices (e.g. cellular phones, lap top computers, camcorders, cameras, tools). Current intensive efforts are under way to develop systems for automotive industry within the framework of electrically propelled mobility (e.g. hybrid electric vehicles, plug-in hybrid electric vehicles, full electric vehicles) and also for the energy storage market (e.g. electrical grid stability, renewable energies). Besides the different systems (cell chemistries), electrochemical cells and batteries were developed and are offered in many shapes, sizes and designs, in order to meet performance and design requirements of the widespread applications. Proper packaging is thereby one important technological step for designing optimum, reliable and safe batteries for operation. In this contribution, current packaging approaches of cells and batteries together with the corresponding materials are discussed. The focus is laid on rechargeable systems for industrial applications (i.e. alkaline systems, lithium-ion, lead-acid). In principle, four different cell types (shapes) can be identified - button, cylindrical, prismatic and pouch. Cell size can be either in accordance with international (e.g. International Electrotechnical Commission, IEC) or other standards or can meet application-specific dimensions. Since cell housing or container, terminals and, if necessary, safety installations as inactive (non-reactive) materials reduce energy density of the battery, the development of low-weight packages is a challenging task. In addition to that, other requirements have to be fulfilled: mechanical stability and durability, sealing (e.g. high permeation barrier against humidity for lithium-ion technology), high packing efficiency, possible installation of safety devices (current interrupt device

  16. New package for CMOS sensors

    Science.gov (United States)

    Diot, Jean-Luc; Loo, Kum Weng; Moscicki, Jean-Pierre; Ng, Hun Shen; Tee, Tong Yan; Teysseyre, Jerome; Yap, Daniel

    2004-02-01

    Cost is the main drawback of existing packages for C-MOS sensors (mainly CLCC family). Alternative packages are thus developed world-wide. And in particular, S.T.Microelectronics has studied a low cost alternative packages based on QFN structure, still with a cavity. Intensive work was done to optimize the over-molding operation forming the cavity onto a metallic lead-frame (metallic lead-frame is a low cost substrate allowing very good mechanical definition of the final package). Material selection (thermo-set resin and glue for glass sealing) was done through standard reliability tests for cavity packages (Moisture Sensitivity Level 3 followed by temperature cycling, humidity storage and high temperature storage). As this package concept is new (without leads protruding the molded cavity), the effect of variation of package dimensions, as well as board lay-out design, are simulated on package life time (during temperature cycling, thermal mismatch between board and package leads to thermal fatigue of solder joints). These simulations are correlated with an experimental temperature cycling test with daisy-chain packages.

  17. Safety Analysis Report for packaging (onsite) steel waste package

    Energy Technology Data Exchange (ETDEWEB)

    BOEHNKE, W.M.

    2000-07-13

    The steel waste package is used primarily for the shipment of remote-handled radioactive waste from the 324 Building to the 200 Area for interim storage. The steel waste package is authorized for shipment of transuranic isotopes. The maximum allowable radioactive material that is authorized is 500,000 Ci. This exceeds the highway route controlled quantity (3,000 A{sub 2}s) and is a type B packaging.

  18. Intradermal normal saline solution, self-selected music, and insertion difficulty effects on intravenous insertion pain.

    Science.gov (United States)

    Jacobson, A F

    1999-01-01

    To examine the effect of listening to self-selected music versus an intradermal injection of normal saline solution on the intensity and distress of intravenous (IV) catheter insertion pain. Prospective, randomized, controlled study. Inpatient and outpatient units in 2 university-affiliated southwestern medical centers. One hundred ten adult inpatients and outpatients undergoing IV therapy. Pain intensity, pain distress, and IV insertion difficulty visual analog scales. Patients were randomly assigned to receive an intradermal injection of normal saline solution, listen with headphones to self-selected music, or be in a control group for IV insertion. A MANOVA revealed no statistically significant multivariate or univariate differences in pain by treatment group, but significantly higher pain distress scores with failed IV insertions. The pain intensity and distress scores were significantly higher in the saline solution group when compared with the music and control groups combined. Insertion difficulty was significantly positively correlated with pain intensity and distress for the entire sample, with weak, nonsignificant correlations in the music group. Intradermal unpreserved saline solution contributes to greater pain intensity and distress, greater insertion difficulty, and a higher failure rate than the use of music or routine IV insertion. Listening to preferred music attenuates the effect of insertion difficulty on IV insertion pain. Intravenous insertion attempts were unsuccessful in more than one third of the subjects, resulting in higher pain distress scores. Further research is needed on interventions to reduce IV insertion pain and on factors contributing to IV insertion failure.

  19. BOK-Underfill Optimization for FPGA Package/Assembly

    Science.gov (United States)

    Ghaffarian, Reza

    2011-01-01

    Commercial-off-the-shelf area array package technologies in high-reliability versions are being considered for NASA electronic systems. These packages are prone to early failure due to the severe mechanical shock and vibration of launch, as well as other less severe conditions, such as mechanical loading during descent, rough terrain mobility, handling, and ground tests. As the density of these packages increases and the size of ball interconnections decrease, susceptibility to mechanical loading and cycling fatigue grows. This report presents a summary of the body of knowledge developed for the evaluation of area array packages and is based on surveys of literature from industry and academia. For high-reliability applications, the limited data that exists will be presented. Most data from industry deals with mechanical fatigue caused by four-point bend tests, as well as from drop tests for hand-held electronics; the most recent data will be presented, along with a brief background of prior literature. Understanding the key design guidelines and failure mechanisms from past tests is critical to developing an approach that will minimize future failures. Additional specific testing enables low-risk insertion of these advanced electronic packages.

  20. Long-distance effects of insertional mutagenesis.

    Directory of Open Access Journals (Sweden)

    Ruchi Singhal

    2011-01-01

    Full Text Available Most common systems of genetic engineering of mammalian cells are associated with insertional mutagenesis of the modified cells. Insertional mutagenesis is also a popular approach to generate random alterations for gene discovery projects. A better understanding of the interaction of the structural elements within an insertional mutagen and the ability of such elements to influence host genes at various distances away from the insertion site is a matter of considerable practical importance.We observed that, in the context of a lentiviral construct, a transcript, which is initiated at an internal CMV promoter/enhancer region and incorporates a splice donor site, is able to extend past a collinear viral LTR and trap exons of host genes, while the polyadenylation signal, which is naturally present in the LTR, is spliced out. Unexpectedly, when a vector, which utilizes this phenomenon, was used to produce mutants with elevated activity of NF-κB, we found mutants, which owed their phenotype to the effect of the insert on a gene located tens or even hundreds of kilobases away from the insertion site. This effect did not result from a CMV-driven transcript, but was sensitive to functional suppression of the insert. Interestingly, despite the long-distance effect, expression of loci most closely positioned to the insert appeared unaffected.We concluded that a polyadenylation signal in a retroviral LTR, when occurring within an intron, is an inefficient barrier against the formation of a hybrid transcript, and that a vector containing a strong enhancer may selectively affect the function of genes far away from its insertion site. These phenomena have to be considered when experimental or therapeutic transduction is performed. In particular, the long-distance effects of insertional mutagenesis bring into question the relevance of the lists of disease-associated retroviral integration targets, which did not undergo functional validation.

  1. CH Packaging Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2008-09-11

    This document provides the user with instructions for assembling a payload. All the steps in Subsections 1.2, Preparing 55-Gallon Drum Payload Assembly; 1.3, Preparing "Short" 85-Gallon Drum Payload Assembly (TRUPACT-II and HalfPACT); 1.4, Preparing "Tall" 85-gallon Drum Payload Assembly (HalfPACT only); 1.5, Preparing 100-Gallon Drum Payload Assembly; 1.6, Preparing SWB Payload Assembly; and 1.7, Preparing TDOP Payload Assembly, must be completed, but may be performed in any order as long as radiological control steps are not bypassed. Transport trailer operations, package loading and unloading from transport trailers, hoisting and rigging activities such as ACGLF operations, equipment checkout and shutdown, and component inspection activities must be performed, but may be performed in any order and in parallel with other activities as long as radiological control steps are not bypassed. Steps involving OCA/ICV lid removal/installation and payload removal/loading may be performed in parallel if there are multiple operators working on the same packaging. Steps involving removal/installation of OCV/ICV upper and lower main O-rings must be performed in sequence.

  2. CH Packaging Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2009-05-27

    This document provides the user with instructions for assembling a payload. All the steps in Subsections 1.2, Preparing 55-Gallon Drum Payload Assembly; 1.3, Preparing "Short" 85-Gallon Drum Payload Assembly (TRUPACT-II and HalfPACT); 1.4, Preparing "Tall" 85-Gallon Drum Payload Assembly (HalfPACT only); 1.5, Preparing 100-Gallon Drum Payload Assembly; 1.6, Preparing Shielded Container Payload Assembly; 1.7, Preparing SWB Payload Assembly; and 1.8, Preparing TDOP Payload Assembly, must be completed, but may be performed in any order as long as radiological control steps are not bypassed. Transport trailer operations, package loading and unloading from transport trailers, hoisting and rigging activities such as ACGLF operations, equipment checkout and shutdown, and component inspection activities must be performed, but may be performed in any order and in parallel with other activities as long as radiological control steps are not bypassed. Steps involving OCA/ICV lid removal/installation and payload removal/loading may be performed in parallel if there are multiple operators working on the same packaging. Steps involving removal/installation of OCV/ICV upper and lower main O-rings must be performed in sequence, except as noted.

  3. Teres major muscle - insertion footprint.

    Science.gov (United States)

    Dancker, Malte; Lambert, Simon; Brenner, Erich

    2017-05-01

    Teres major muscle (TM) and latissimus dorsi muscle (LD) are frequently used in muscle transfers around the shoulder girdle. Some authors have suggested harvesting techniques in which the muscle is detached in continuity with a bone segment. Information on the bony attachment footprint of these muscles is lacking. The purpose of this study was to investigate the region of attachment of the TM to facilitate safe and complete harvesting with a bone segment where it is indicated, and to determine the relationship of the TM footprint with that of the LD. Twenty-eight upper extremities of 14 human cadavers (six female, eight male) were investigated during the students' dissection course in the winter term 2012. The attachment footprints were photographed and the images were processed with ImageJ Version 1.46r. The TM attachment footprint at the crest of the lesser tubercle had an average dimension of 187 ± 89 mm2 . It was 49.6 ± 7.9 mm long and 7.4 ± 2.5 mm wide. The bony attachment of the LD within the bicipital groove, just below the tendon of the long head of the biceps muscle, had an area of 94 ± 37 mm2 . It was 36.5 ± 8 mm long and 3.7 ± 1.2 mm wide. Both muscles were separated by 4.4 ± 1.7 mm and their attachments overlapped in the craniocaudal direction by 24.4 ± 12.4 mm. Earlier studies have investigated the dimensions of the muscles' tendons close to the attachment not the bony attachment itself. The dimension of the attachment of the TM was larger than that of the LD. The ratio between the footprint areas was approximately 2:1. This information should be considered by surgeons undertaking transfers, which include a bony segment of the muscle insertion. © 2017 The Authors. Journal of Anatomy published by John Wiley & Sons Ltd on behalf of Anatomical Society.

  4. Central Solenoid Insert Technical Specification

    Energy Technology Data Exchange (ETDEWEB)

    Martovetsky, Nicolai N [ORNL; Smirnov, Alexandre [ORNL

    2011-09-01

    The US ITER Project Office (USIPO) is responsible for the ITER central solenoid (CS) contribution to the ITER project. The Central Solenoid Insert (CSI) project will allow ITER validation the appropriate lengths of the conductors to be used in the full-scale CS coils under relevant conditions. The ITER Program plans to build and test a CSI to verify the performance of the CS conductor. The CSI is a one-layer solenoid with an inner diameter of 1.48 m and a height of 4.45 m between electric terminal ends. The coil weight with the terminals is approximately 820 kg without insulation. The major goal of the CSI is to measure the temperature margin of the CS under the ITER direct current (DC) operating conditions, including determining sensitivity to load cycles. Performance of the joints, ramp rate sensitivity, and stability against thermal or electromagnetic disturbances, electrical insulation, losses, and instrumentation are addressed separately and therefore are not major goals in this project. However, losses and joint performance will be tested during the CSI testing campaign. The USIPO will build the CSI that will be tested at the Central Solenoid Model Coil (CSMC) Test Facility at the Japan Atomic Energy Agency (JAEA), Naka, Japan. The industrial vendors (the Suppliers) will report to the USIPO (the Company). All approvals to proceed will be issued by the Company, which in some cases, as specified in this document, will also require the approval of the ITER Organization. Responsibilities and obligations will be covered by respective contracts between the USIPO, called Company interchangeably, and the industrial Prime Contractors, called Suppliers. Different stages of work may be performed by more than one Prime Contractor, as described in this specification. Technical requirements of the contract between the Company and the Prime Contractor will be covered by the Fabrication Specifications developed by the Prime Contractor based on this document and approved by

  5. Functional Package Management with Guix

    OpenAIRE

    Courtès, Ludovic

    2013-01-01

    International audience; We describe the design and implementation of GNU Guix, a purely functional package manager designed to support a complete GNU/Linux distribution. Guix supports transactional upgrades and roll-backs, unprivileged package management, per-user profiles, and garbage collection. It builds upon the low-level build and deployment layer of the Nix package manager. Guix uses Scheme as its programming interface. In particular, we devise an embedded domain-specific language (EDSL...

  6. Biodegradable packaging materials : case: PLA

    OpenAIRE

    Jama, Mohamed

    2017-01-01

    The main aim of this bachelor thesis was to investigate the possibility of biodegradable packaging materials. Plastics and other non-degradable packaging materials have been used for many years and they have a negative impact on the environment since they do not degrade. Different research methods are used to get authentic results, which simplifies using biodegradable packaging materials. There were two biodegradability testing methods, which has been applied to this task:-, testing biode...

  7. IN-PACKAGE CHEMISTRY ABSTRACTION

    Energy Technology Data Exchange (ETDEWEB)

    E. Thomas

    2005-07-14

    This report was developed in accordance with the requirements in ''Technical Work Plan for Postclosure Waste Form Modeling'' (BSC 2005 [DIRS 173246]). The purpose of the in-package chemistry model is to predict the bulk chemistry inside of a breached waste package and to provide simplified expressions of that chemistry as a function of time after breach to Total Systems Performance Assessment for the License Application (TSPA-LA). The scope of this report is to describe the development and validation of the in-package chemistry model. The in-package model is a combination of two models, a batch reactor model, which uses the EQ3/6 geochemistry-modeling tool, and a surface complexation model, which is applied to the results of the batch reactor model. The batch reactor model considers chemical interactions of water with the waste package materials, and the waste form for commercial spent nuclear fuel (CSNF) waste packages and codisposed (CDSP) waste packages containing high-level waste glass (HLWG) and DOE spent fuel. The surface complexation model includes the impact of fluid-surface interactions (i.e., surface complexation) on the resulting fluid composition. The model examines two types of water influx: (1) the condensation of water vapor diffusing into the waste package, and (2) seepage water entering the waste package as a liquid from the drift. (1) Vapor-Influx Case: The condensation of vapor onto the waste package internals is simulated as pure H{sub 2}O and enters at a rate determined by the water vapor pressure for representative temperature and relative humidity conditions. (2) Liquid-Influx Case: The water entering a waste package from the drift is simulated as typical groundwater and enters at a rate determined by the amount of seepage available to flow through openings in a breached waste package.

  8. Mould Design and Material selection for Film Insert Moulding of Direct Methanol Fuel Cell Packaging

    DEFF Research Database (Denmark)

    Wöhner, Timo; Senkbeil, S.; Olesen, T. L.

    2015-01-01

    This paper presents the mould design for an injection moulding (IM) process for the production of a methanol container for the use in small, passive Direct Methanol Fuel Cell (DMFC) systems, which are intended to be used in behind-the-ear hearing aid systems. One of the crucial properties...

  9. About the ZOOM minimization package

    Energy Technology Data Exchange (ETDEWEB)

    Fischler, M.; Sachs, D.; /Fermilab

    2004-11-01

    A new object-oriented Minimization package is available for distribution in the same manner as CLHEP. This package, designed for use in HEP applications, has all the capabilities of Minuit, but is a re-write from scratch, adhering to modern C++ design principles. A primary goal of this package is extensibility in several directions, so that its capabilities can be kept fresh with as little maintenance effort as possible. This package is distinguished by the priority that was assigned to C++ design issues, and the focus on producing an extensible system that will resist becoming obsolete.

  10. The LISA Technology Package

    Science.gov (United States)

    Livas, Jeff

    2009-01-01

    The LISA Technology Package (LTP) is the payload of the European Space Agency's LISA Pathfinder mission. LISA Pathfinder was instigated to test, in a flight environment, the critical technologies required by LISA; namely, the inertial sensing subsystem and associated control laws and micro-Newton thrusters required to place a macroscopic test mass in pure free-fall. The UP is in the late stages of development -- all subsystems are currently either in the final stages of manufacture or in test. Available flight units are being integrated into the real-time testbeds for system verification tests. This poster will describe the UP and its subsystems, give the current status of the hardware and test campaign, and outline the future milestones leading to the UP delivery.

  11. Tritium waste package

    Science.gov (United States)

    Rossmassler, Rich; Ciebiera, Lloyd; Tulipano, Francis J.; Vinson, Sylvester; Walters, R. Thomas

    1995-01-01

    A containment and waste package system for processing and shipping tritium xide waste received from a process gas includes an outer drum and an inner drum containing a disposable molecular sieve bed (DMSB) seated within outer drum. The DMSB includes an inlet diffuser assembly, an outlet diffuser assembly, and a hydrogen catalytic recombiner. The DMSB absorbs tritium oxide from the process gas and converts it to a solid form so that the tritium is contained during shipment to a disposal site. The DMSB is filled with type 4A molecular sieve pellets capable of adsorbing up to 1000 curies of tritium. The recombiner contains a sufficient amount of catalyst to cause any hydrogen add oxygen present in the process gas to recombine to form water vapor, which is then adsorbed onto the DMSB.

  12. Electronic equipment packaging technology

    CERN Document Server

    Ginsberg, Gerald L

    1992-01-01

    The last twenty years have seen major advances in the electronics industry. Perhaps the most significant aspect of these advances has been the significant role that electronic equipment plays in almost all product markets. Even though electronic equipment is used in a broad base of applications, many future applications have yet to be conceived. This versatility of electron­ ics has been brought about primarily by the significant advances that have been made in integrated circuit technology. The electronic product user is rarely aware of the integrated circuits within the equipment. However, the user is often very aware of the size, weight, mod­ ularity, maintainability, aesthetics, and human interface features of the product. In fact, these are aspects of the products that often are instrumental in deter­ mining its success or failure in the marketplace. Optimizing these and other product features is the primary role of Electronic Equipment Packaging Technology. As the electronics industry continues to pr...

  13. HB+ inserted into the CMS Solenoid

    CERN Multimedia

    Tejinder S. Virdee, CERN

    2006-01-01

    The first half of the barrel hadron calorimeter (HB+) has been inserted into the superconducting solenoid of CMS, in preparation for the magnet test and cosmic challenge. The operation went smoothly, lasting a couple of days.

  14. Prescription Custom Orthotics and Shoe Inserts

    Science.gov (United States)

    ... cost more than shoe inserts purchased in a retail store, but the additional cost is usually well worth ... supports that you can order online or at retail stores. Unless the device has been prescribed by a ...

  15. Bulkhead insert for an internal combustion engine

    Energy Technology Data Exchange (ETDEWEB)

    Maki, Clifford E.; Chottiner, Jeffrey Eliot; Williams, Rick L.; Thibault, Mark W.; Ervin, James Douglas; Boileau, James Maurice; McKeough, Bryan

    2017-08-01

    An engine includes a cylinder block defining at least one main bearing bulkhead adjacent to a cylinder, and a crankshaft rotatably housed within the block by a main bearing. A bulkhead insert has a cap portion, and an insert portion provided within the bulkhead. The insert portion has having first and second end regions connected by first and second straps. Each strap having a flanged beam cross section. The first and second ends of the insert portion are configured to connect a main bearing cap column to a cylinder head column. Each of the first and second end regions define at least one protrusion having a surface substantially normal to engine combustion and reactive loads. The cap portion is configured to mate with the first end region at the main bearing cap column and support the main bearing.

  16. Immediate postabortal insertion of intrauterine devices.

    Science.gov (United States)

    Grimes, D; Schulz, K; Stanwood, N

    2004-10-18

    Insertion of an intrauterine device (IUD) immediately after an abortion has several potential advantages. The woman is known not to be pregnant, a major concern for clinicians. For example, many clinicians refuse to insert an IUD in a woman who is not menstruating. After induced abortion, a woman's motivation to use contraception may be high. However, insertion of an IUD immediately after a pregnancy ends carries potential risks as well. For example, the risk of spontaneous expulsion may be increased due to recent cervical dilation. To assess the safety and efficacy of IUD insertion immediately after spontaneous or induced abortion. We used MEDLINE, Popline, and EMBASE computer searches, supplemented by review articles and contacts with investigators. We sought all randomized controlled trials that had at least one treatment arm that involved IUD insertion immediately after an induced abortion or after curettage for spontaneous abortion. We identified 12 trials which described random assignment but excluded three from this review. Two of these revealed unethical research conduct, and one used alternate assignment to treatments. We evaluated the methodological quality of each report and abstracted information onto a data collection form. We focused on gross discontinuation rates (single-decrement life table analysis) for accidental pregnancy, perforation, expulsion, and pelvic inflammatory disease. We entered the data into RevMan 3.1 for analysis of Peto odds ratios. In large multicenter trials, the TCu 220C device proved superior to either the Lippes Loop D or the Copper 7 IUDs for immediate postabortal insertion. In single-center trials, the Nova T IUD had a significantly higher discontinuation rate for pregnancy than did the Multiload 250 (OR 4.5; 95% CI 1.0-19.8), while the Nova T had a significantly lower discontinuation rate for pregnancy than did the TCu 200 (OR 0.3; 95% CI 0.1-0.9). The levonorgestrel-releasing device was more effective in preventing

  17. Ensuring socially responsible packaging design

    DEFF Research Database (Denmark)

    Geert Jensen, Birgitte

    Most consumers have experienced occasional problems with opening packaging. Tomato sauce from the tinned mackerel splattered all over the kitchen counter, the unrelenting pickle jar lid, and the package of sliced ham that cannot be opened without a knife or a pair of scissors. The research project...

  18. Packaging perspective, 1910-1985

    Science.gov (United States)

    John W. Koning; James F. Laundrie

    1985-01-01

    For 75 years the Forest Products Laboratory has been concerned for the wise use of wood. One of the major uses of wood is packaging. This report summarizes the research reports completed in packaging and relates the output in terms of forest management and return on the taxpayer’s investment.

  19. Gentoo package dependencies over time

    NARCIS (Netherlands)

    Bloemen, Remco; Amrit, Chintan Amrit; Kuhlmann, Stefan; Ordonez Matamoros, Hector Gonzalo

    2014-01-01

    Open source distributions such as Gentoo need to accurately track dependency relations between software packages in order to install working systems. To do this, Gentoo has a carefully authored database containing those relations. In this paper, we extract the Gentoo package dependency graph and its

  20. Packaging Software Assets for Reuse

    Science.gov (United States)

    Mattmann, C. A.; Marshall, J. J.; Downs, R. R.

    2010-12-01

    The reuse of existing software assets such as code, architecture, libraries, and modules in current software and systems development projects can provide many benefits, including reduced costs, in time and effort, and increased reliability. Many reusable assets are currently available in various online catalogs and repositories, usually broken down by disciplines such as programming language (Ibiblio for Maven/Java developers, PyPI for Python developers, CPAN for Perl developers, etc.). The way these assets are packaged for distribution can play a role in their reuse - an asset that is packaged simply and logically is typically easier to understand, install, and use, thereby increasing its reusability. A well-packaged asset has advantages in being more reusable and thus more likely to provide benefits through its reuse. This presentation will discuss various aspects of software asset packaging and how they can affect the reusability of the assets. The characteristics of well-packaged software will be described. A software packaging domain model will be introduced, and some existing packaging approaches examined. An example case study of a Reuse Enablement System (RES), currently being created by near-term Earth science decadal survey missions, will provide information about the use of the domain model. Awareness of these factors will help software developers package their reusable assets so that they can provide the most benefits for software reuse.

  1. Insertional Polymorphism and Antiquity of PDR1 Retrotransposon Insertions in Pisum Species

    Science.gov (United States)

    Jing, Runchun; Knox, Maggie R.; Lee, Jennifer M.; Vershinin, Alexander V.; Ambrose, Michael; Ellis, T. H. Noel; Flavell, Andrew J.

    2005-01-01

    Sequences flanking 73 insertions of the retrotransposon PDR1 have been characterized, together with an additional 270 flanking regions from one side alone, from a diverse collection of Pisum germ plasm. Most of the identified flanking sequences are repetitious DNAs but more than expected (7%) lie within nuclear gene protein-coding regions. The approximate age of 52 of the PDR1 insertions has been determined by measuring sequence divergence among LTR pairs. These data show that PDR1 transpositions occurred within the last 5 MY, with a peak at 1–2.5 MYA. The insertional polymorphism of 68 insertions has been assessed across 47 selected Pisum accessions, representing the diversity of the genus. None of the insertions are fixed, showing that PDR1 insertions can persist in a polymorphic state for millions of years in Pisum. The insertional polymorphism data have been compared with the age estimations to ask what rules control the proliferation of PDR1 insertions in Pisum. Relatively recent insertions ( ∼2.5 MYA) are mostly found in small subsets of Pisum. Finally, the average age estimate for PDR1 insertions, together with an existing data set for PDR1 retrotransposon SSAP markers, has been used to derive an estimate of the effective population size for Pisum of ∼7.5 × 105. PMID:16085698

  2. Non-insertional tendinopathy of the subscapularis

    OpenAIRE

    Dierckman, Brian D.; Shah, Nirav R.; Larose, Connor R.; Stacey Gerbrandt; Getelman, Mark H.

    2013-01-01

    Purpose: (1) Describe a previously unreported finding involving the intra-articular portion of the subscapularis, the Conrad lesion. (2) Describe a novel classification system for the spectrum of non-insertional tendinopathy of the subscapularis. (3) Report the outcomes of surgical treatment of this spectrum of pathology. Materials and Methods: Outcomes of 34 patients (23 males and 11 females, mean age 60.5 ± 7.5) with non-insertional tendinopathy of the subscapularis treated arthroscopic...

  3. 19 CFR 191.13 - Packaging materials.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Packaging materials. 191.13 Section 191.13 Customs... (CONTINUED) DRAWBACK General Provisions § 191.13 Packaging materials. (a) Imported packaging material... packaging material when used to package or repackage merchandise or articles exported or destroyed pursuant...

  4. Response of antioxidant activity and sensory quality in fresh-cut pear as affected by high O(2) active packaging in comparison with low O(2) packaging.

    Science.gov (United States)

    Li, W L; Li, X H; Fan, X; Tang, Y; Yun, J

    2012-06-01

    Effects of active modified atmosphere packaging (initial O(2)/CO(2): 5/5; 30/5; and 80/0) and passive packaging [initial O(2)/CO(2): 20.8/0 (air)] on the antioxidant capacity and sensory quality of fresh-cut 'Yaoshan' pear stored at 4 °C for 12 days were investigated. Samples stored in high O(2) (30% and 80%) packages had higher phenolics and anthocyanin contents compared with those in passive and low O(2) packages. After 12 days of storage, phenolics and anthocyanin contents of 80% O(2) samples were 2.5 and 12 times, respectively, higher than those in the passive package and 3 and 2 times higher than those in low O(2) package. High O(2) modified atmosphere packaging was effective in keeping free radical scavenging capacity as measured by the DPPH assay. The sensory evaluation indicated that surface color of cut fruits were stable for at least 12 days in the high O(2) modified atmosphere packaging. The results suggested that high O(2) modified atmosphere packaging could be used to inhibit browning and prolong the shelf life of fresh-cut 'Yaoshan' pears in spite of more than 50% loss in vitamin C content.

  5. Device-packaging method and apparatus for optoelectronic circuits

    Science.gov (United States)

    Zortman, William A.; Henry, Michael David; Jarecki, Jr., Robert L.

    2017-04-25

    An optoelectronic device package and a method for its fabrication are provided. The device package includes a lid die and an active die that is sealed or sealable to the lid die and in which one or more optical waveguides are integrally defined. The active die includes one or more active device regions, i.e. integral optoelectronic devices or etched cavities for placement of discrete optoelectronic devices. Optical waveguides terminate at active device regions so that they can be coupled to them. Slots are defined in peripheral parts of the active dies. At least some of the slots are aligned with the ends of integral optical waveguides so that optical fibers or optoelectronic devices inserted in the slots can optically couple to the waveguides.

  6. Nucleosome Packaging and Nucleosome Positioning of Genomic DNA

    Science.gov (United States)

    Lowary, P. T.; Widom, J.

    1997-02-01

    The goals of this study were to assess the extent to which bulk genomic DNA sequences contribute to their own packaging in nucleosomes and to reveal the relationship between nucleosome packaging and positioning. Using a competitive nucleosome reconstitution assay, we found that at least 95% of bulk DNA sequences have an affinity for histone octamer in nucleosomes that is similar to that of randomly synthesized DNA; they contribute little to their own packaging at the level of individual nucleosomes. An equation was developed that relates the measured free energy to the fractional occupancy of specific nucleosome positions. Evidently, the bulk of eukaryotic genomic DNA is also not evolved or constrained for significant sequence-directed nucleosome positioning at the level of individual nucleosomes. Implications for gene regulation in vivo are discussed.

  7. Bidirectional Conditional Insertion Sort algorithm; An efficient progress on the classical insertion sort

    OpenAIRE

    Mohammed, Adnan Saher; Amrahov, Şahin Emrah; Çelebi, Fatih V.

    2016-01-01

    In this paper, we proposed a new efficient sorting algorithm based on insertion sort concept. The proposed algorithm called Bidirectional Conditional Insertion Sort (BCIS). It is in-place sorting algorithm and it has remarkably efficient average case time complexity when compared with classical insertion sort (IS). By comparing our new proposed algorithm with the Quicksort algorithm, BCIS indicated faster average case time for relatively small size arrays up to 1500 elements. Furthermore, BCI...

  8. Readability of medicinal package leaflets: a systematic review.

    Science.gov (United States)

    Pires, Carla; Vigário, Marina; Cavaco, Afonso

    2015-01-01

    OBJECTIVE To review studies on the readability of package leaflets of medicinal products for human use. METHODS We conducted a systematic literature review between 2008 and 2013 using the keywords "Readability and Package Leaflet" and "Readability and Package Insert" in the academic search engine Biblioteca do Conhecimento Online, comprising different bibliographic resources/databases. The preferred reporting items for systematic reviews and meta-analyses criteria were applied to prepare the draft of the report. Quantitative and qualitative original studies were included. Opinion or review studies not written in English, Portuguese, Italian, French, or Spanish were excluded. RESULTS We identified 202 studies, of which 180 were excluded and 22 were enrolled [two enrolling healthcare professionals, 10 enrolling other type of participants (including patients), three focused on adverse reactions, and 7 descriptive studies]. The package leaflets presented various readability problems, such as complex and difficult to understand texts, small font size, or few illustrations. The main methods to assess the readability of the package leaflet were usability tests or legibility formulae. Limitations with these methods included reduced number of participants; lack of readability formulas specifically validated for specific languages (e.g., Portuguese); and absence of an assessment on patients literacy, health knowledge, cognitive skills, levels of satisfaction, and opinions. CONCLUSIONS Overall, the package leaflets presented various readability problems. In this review, some methodological limitations were identified, including the participation of a limited number of patients and healthcare professionals, the absence of prior assessments of participant literacy, humor or sense of satisfaction, or the predominance of studies not based on role-plays about the use of medicines. These limitations should be avoided in future studies and be considered when interpreting the results.

  9. In-Package Chemistry Abstraction

    Energy Technology Data Exchange (ETDEWEB)

    E. Thomas

    2004-11-09

    This report was developed in accordance with the requirements in ''Technical Work Plan for: Regulatory Integration Modeling and Analysis of the Waste Form and Waste Package'' (BSC 2004 [DIRS 171583]). The purpose of the in-package chemistry model is to predict the bulk chemistry inside of a breached waste package and to provide simplified expressions of that chemistry as function of time after breach to Total Systems Performance Assessment for the License Application (TSPA-LA). The scope of this report is to describe the development and validation of the in-package chemistry model. The in-package model is a combination of two models, a batch reactor model that uses the EQ3/6 geochemistry-modeling tool, and a surface complexation model that is applied to the results of the batch reactor model. The batch reactor model considers chemical interactions of water with the waste package materials and the waste form for commercial spent nuclear fuel (CSNF) waste packages and codisposed waste packages that contain both high-level waste glass (HLWG) and DOE spent fuel. The surface complexation model includes the impact of fluid-surface interactions (i.e., surface complexation) on the resulting fluid composition. The model examines two types of water influx: (1) the condensation of water vapor that diffuses into the waste package, and (2) seepage water that enters the waste package from the drift as a liquid. (1) Vapor Influx Case: The condensation of vapor onto the waste package internals is simulated as pure H2O and enters at a rate determined by the water vapor pressure for representative temperature and relative humidity conditions. (2) Water Influx Case: The water entering a waste package from the drift is simulated as typical groundwater and enters at a rate determined by the amount of seepage available to flow through openings in a breached waste package. TSPA-LA uses the vapor influx case for the nominal scenario for simulations where the waste

  10. Naval Waste Package Design Sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    T. Schmitt

    2006-12-13

    The purpose of this calculation is to determine the sensitivity of the structural response of the Naval waste packages to varying inner cavity dimensions when subjected to a comer drop and tip-over from elevated surface. This calculation will also determine the sensitivity of the structural response of the Naval waste packages to the upper bound of the naval canister masses. The scope of this document is limited to reporting the calculation results in terms of through-wall stress intensities in the outer corrosion barrier. This calculation is intended for use in support of the preliminary design activities for the license application design of the Naval waste package. It examines the effects of small changes between the naval canister and the inner vessel, and in these dimensions, the Naval Long waste package and Naval Short waste package are similar. Therefore, only the Naval Long waste package is used in this calculation and is based on the proposed potential designs presented by the drawings and sketches in References 2.1.10 to 2.1.17 and 2.1.20. All conclusions are valid for both the Naval Long and Naval Short waste packages.

  11. Perfume Packaging, Seduction and Gender

    Directory of Open Access Journals (Sweden)

    Magdalena Petersson McIntyre

    2013-06-01

    Full Text Available This article examines gender and cultural sense-making in relation to perfumes and their packaging. Gendered meanings of seduction, choice, consumption and taste are brought to the fore with the use of go-along interviews with consumers in per-fume stores. Meeting luxury packages in this feminized environment made the interviewed women speak of bottles as objects to fall in love with and they de-scribed packages as the active part in an act of seduction where they were expect-ing packages to persuade them into consumption. The interviewed men on the other hand portrayed themselves as active choice-makers and stressed that they were always in control and not seduced by packaging. However, while their ways of explaining their relationship with packaging on the surface seems to confirm cultural generalizations in relation to gender and seduction, the article argues that letting oneself be seduced is no less active than seducing. Based on a combination of actor network theories and theories of gender performativity the article points to the agency of packaging for constructions of gender and understands the inter-viewees as equally animated by the flows of passion which guide their actions.

  12. Insertion Sort is O(n log n)

    OpenAIRE

    Bender, Michael A.; Farach-Colton, Martin; Mosteiro, Miguel

    2004-01-01

    Traditional Insertion Sort runs in O(n^2) time because each insertion takes O(n) time. When people run Insertion Sort in the physical world, they leave gaps between items to accelerate insertions. Gaps help in computers as well. This paper shows that Gapped Insertion Sort has insertion times of O(log n) with high probability, yielding a total running time of O(n log n) with high probability.

  13. Method of forming a package for MEMS-based fuel cell

    Science.gov (United States)

    Morse, Jeffrey D; Jankowski, Alan F

    2013-05-21

    A MEMS-based fuel cell package and method thereof is disclosed. The fuel cell package comprises seven layers: (1) a sub-package fuel reservoir interface layer, (2) an anode manifold support layer, (3) a fuel/anode manifold and resistive heater layer, (4) a Thick Film Microporous Flow Host Structure layer containing a fuel cell, (5) an air manifold layer, (6) a cathode manifold support structure layer, and (7) a cap. Fuel cell packages with more than one fuel cell are formed by positioning stacks of these layers in series and/or parallel. The fuel cell package materials such as a molded plastic or a ceramic green tape material can be patterned, aligned and stacked to form three dimensional microfluidic channels that provide electrical feedthroughs from various layers which are bonded together and mechanically support a MEMS-based miniature fuel cell. The package incorporates resistive heating elements to control the temperature of the fuel cell stack. The package is fired to form a bond between the layers and one or more microporous flow host structures containing fuel cells are inserted within the Thick Film Microporous Flow Host Structure layer of the package.

  14. Safety evaluation for packaging (onsite) concrete-lined waste packaging

    Energy Technology Data Exchange (ETDEWEB)

    Romano, T.

    1997-09-25

    The Pacific Northwest National Laboratory developed a package to ship Type A, non-transuranic, fissile excepted quantities of liquid or solid radioactive material and radioactive mixed waste to the Central Waste Complex for storage on the Hanford Site.

  15. Characterization of integrated circuit packaging materials

    CERN Document Server

    Moore, Thomas

    1993-01-01

    Chapters in this volume address important characteristics of IC packages. Analytical techniques appropriate for IC package characterization are demonstrated through examples of the measurement of critical performance parameters and the analysis of key technological problems of IC packages. Issues are discussed which affect a variety of package types, including plastic surface-mount packages, hermetic packages, and advanced designs such as flip-chip, chip-on-board and multi-chip models.

  16. Hamstring tendons insertion - an anatomical study

    Directory of Open Access Journals (Sweden)

    Cristiano Antonio Grassi

    2013-09-01

    Full Text Available OBJECTIVE: To study the anatomy of the hamstring tendons insertion and anatomical rela-tionships. METHODS: Ten cadaver knees with medial and anterior intact structures were selected. The dissection was performed from anteromedial access to exposure of the insertion of the flexor tendons (FT, tibial plateau (TP and tibial tuberosity (TT. A needle of 40 × 12 and a caliper were used to measure the distance of the tibial plateau of the knee flexor tendons insertion at 15 mm from the medial border of the patellar tendon and tibial tuberosity to the insertion of the flexor tendons of the knee. The angle between tibial plateau and the insertion of the flexor tendons of the knee (A-TP-FT was calculated using Image Pro Plus software. RESULTS: The mean distance TP-FT was 41 ± 4.6 mm. The distance between the TT-FT was 6.88 ± 1 mm. The (A-TP-FT was 20.3 ± 4.9°. CONCLUSION: In the anterior tibial flexor tendons are about 40 mm from the plateau with an average of 20°.

  17. Large area LED package

    Science.gov (United States)

    Goullon, L.; Jordan, R.; Braun, T.; Bauer, J.; Becker, F.; Hutter, M.; Schneider-Ramelow, M.; Lang, K.-D.

    2015-03-01

    Solid state lighting using LED-dies is a rapidly growing market. LED-dies with the needed increasing luminous flux per chip area produce a lot of heat. Therefore an appropriate thermal management is required for general lighting with LEDdies. One way to avoid overheating and shorter lifetime is the use of many small LED-dies on a large area heat sink (down to 70 μm edge length), so that heat can spread into a large area while at the same time light also appears on a larger area. The handling with such small LED-dies is very difficult because they are too small to be picked with common equipment. Therefore a new concept called collective transfer bonding using a temporary carrier chip was developed. A further benefit of this new technology is the high precision assembly as well as the plane parallel assembly of the LED-dies which is necessary for wire bonding. It has been shown that hundred functional LED-dies were transferred and soldered at the same time. After the assembly a cost effective established PCB-technology was applied to produce a large-area light source consisting of many small LED-dies and electrically connected on a PCB-substrate. The top contacts of the LED-dies were realized by laminating an adhesive copper sheet followed by LDI structuring as known from PCB-via-technology. This assembly can be completed by adding converting and light forming optical elements. In summary two technologies based on standard SMD and PCB technology have been developed for panel level LED packaging up to 610x 457 mm2 area size.

  18. Packaging systems for animal origin food

    Directory of Open Access Journals (Sweden)

    2011-03-01

    Full Text Available The main task of food packaging is to protect the product during storage and transport against the action of biological, chemical and mechanical factors. The paper presents packaging systems for food of animal origin. Vacuum and modified atmosphere packagings were characterised together with novel types of packagings, referred to as intelligent packaging and active packaging. The aim of this paper was to present all advantages and disadvantages of packaging used for meat products. Such list enables to choose the optimal type of packaging for given assortment of food and specific conditions of the transport and storing.

  19. Applications of Active Packaging in Breads

    Directory of Open Access Journals (Sweden)

    Ali Göncü

    2017-10-01

    Full Text Available Changes on consumer preferences lead to innovations and improvements in new packaging technologies. With these new developments passive packaging technologies aiming to protect food nowadays have left their place to active and intelligent packaging technologies that have other various functions beside protection of food. Active packaging is defined as an innovative packaging type and its usage increases the shelf life of food significantly. Applications of active packaging have begun to be used for packaging of breads. In this study active packaging applications in breads have been reviewed.

  20. Rack Insertion End Effector (RIEE) automation

    Science.gov (United States)

    Malladi, Narasimha

    1993-01-01

    NASA is developing a mechanism to manipulate and insert Racks into the Space Station Logistic modules. The mechanism consists of the following: a base with three motorized degrees of freedom, a 3 section motorized boom that goes from 15 to 44 feet in length, and a Rack Insertion End Effector (RIEE) with 5 hand wheels for precise alignment. The robotics section was tasked with the automation of the RIEE unit. In this report, for the automation of the RIEE unit, application of the Perceptics Vision System was conceptually developed to determine the position and orientation of the RIEE relative to the logistic module, and a MathCad program is written to display the needed displacements for precise alignment and final insertion of the Rack. The uniqueness of this report is that the whole report is in fact a MathCad program including text, derivations, and executable equations with example inputs and outputs.

  1. Emotional response towards food packaging

    DEFF Research Database (Denmark)

    Liao, Lewis Xinwei; Corsi, Armando M.; Chrysochou, Polymeros

    2015-01-01

    In this paper we investigate consumers’ emotional responses to food packaging. More specifically, we use self-report and physiological measures to jointly assess emotional responses to three typical food packaging elements: colours (lowwavelength vs. high-wavelength), images (positive vs. negative......) and typefaces (simple vs. ornate). A sample of 120 participants was exposed to mock package design concepts of chocolate blocks. The results suggest that images generate an emotional response that can be measured by both self-report and physiological measures, whereas colours and typefaces generate emotional...... response that can only be measured by self-report measures. We propose that a joint application of selfreport and physiological measures can lead to richer information and wider interpretation of consumer emotional responses to food packaging elements than using either measure alone....

  2. New Packaging for Amplifier Slabs

    Energy Technology Data Exchange (ETDEWEB)

    Riley, M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Thorsness, C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Suratwala, T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Steele, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Rogowski, G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-03-18

    The following memo provides a discussion and detailed procedure for a new finished amplifier slab shipping and storage container. The new package is designed to maintain an environment of <5% RH to minimize weathering.

  3. Packaging Review Guide for Reviewing Safety Analysis Reports for Packagings

    Energy Technology Data Exchange (ETDEWEB)

    DiSabatino, A; Biswas, D; DeMicco, M; Fisher, L E; Hafner, R; Haslam, J; Mok, G; Patel, C; Russell, E

    2007-04-12

    This Packaging Review Guide (PRG) provides guidance for Department of Energy (DOE) review and approval of packagings to transport fissile and Type B quantities of radioactive material. It fulfills, in part, the requirements of DOE Order 460.1B for the Headquarters Certifying Official to establish standards and to provide guidance for the preparation of Safety Analysis Reports for Packagings (SARPs). This PRG is intended for use by the Headquarters Certifying Official and his or her review staff, DOE Secretarial offices, operations/field offices, and applicants for DOE packaging approval. This PRG is generally organized at the section level in a format similar to that recommended in Regulatory Guide 7.9 (RG 7.9). One notable exception is the addition of Section 9 (Quality Assurance), which is not included as a separate chapter in RG 7.9. Within each section, this PRG addresses the technical and regulatory bases for the review, the manner in which the review is accomplished, and findings that are generally applicable for a package that meets the approval standards. This Packaging Review Guide (PRG) provides guidance for DOE review and approval of packagings to transport fissile and Type B quantities of radioactive material. It fulfills, in part, the requirements of DOE O 460.1B for the Headquarters Certifying Official to establish standards and to provide guidance for the preparation of Safety Analysis Reports for Packagings (SARPs). This PRG is intended for use by the Headquarters Certifying Official and his review staff, DOE Secretarial offices, operations/field offices, and applicants for DOE packaging approval. The primary objectives of this PRG are to: (1) Summarize the regulatory requirements for package approval; (2) Describe the technical review procedures by which DOE determines that these requirements have been satisfied; (3) Establish and maintain the quality and uniformity of reviews; (4) Define the base from which to evaluate proposed changes in scope

  4. AliPDU Package Upgrade

    CERN Document Server

    "Martin, Michael

    2015-01-01

    "AliPDU Package" is a set of script, panels, and datapoints designed in WinCC to manage and monitor PDU's. PDU is an essential component in the data center, in order to make data center working properly through the monitoring of power distribution and environmental condition of the data center. In this project "AliPDU Package" is upgraded so it can be used to monitor environmental condition of data center using PDU's and external environmental sensor connected to PDU.

  5. AliPDU Package Upgrade

    CERN Document Server

    Martin, Michael

    2015-01-01

    AliPDU Package is a set of script, panels, and datapoints designed in WinCC to manage and monitor PDU's. PDU is an essential component in the data center, in order to make data center working properly through the monitoring of power distribution and environmental condition of the data center. In this project "AliPDU Package" is upgraded so it can be used to monitor environmental condition of data center using PDU's and external environmental sensor connected to PDU.

  6. Food Packaging for Sustainable Development

    OpenAIRE

    Williams, Helén

    2011-01-01

    Packaging has been on the environmental agenda for decades. It has been discussed and debated within the society mainly as an environmental problem. Production, distribution and consumption of food and drinks contribute significant to the environmental impact. However, consumers in the EU waste about 20% of the food they buy. The function of packaging in reducing the amount of food losses is an important but often neglected environmental issue. This thesis focuses on the functions of packagin...

  7. Packaging food for radiation processing

    Science.gov (United States)

    Komolprasert, Vanee

    2016-12-01

    Irradiation can play an important role in reducing pathogens that cause food borne illness. Food processors and food safety experts prefer that food be irradiated after packaging to prevent post-irradiation contamination. Food irradiation has been studied for the last century. However, the implementation of irradiation on prepackaged food still faces challenges on how to assess the suitability and safety of these packaging materials used during irradiation. Irradiation is known to induce chemical changes to the food packaging materials resulting in the formation of breakdown products, so called radiolysis products (RP), which may migrate into foods and affect the safety of the irradiated foods. Therefore, the safety of the food packaging material (both polymers and adjuvants) must be determined to ensure safety of irradiated packaged food. Evaluating the safety of food packaging materials presents technical challenges because of the range of possible chemicals generated by ionizing radiation. These challenges and the U.S. regulations on food irradiation are discussed in this article.

  8. Antimicrobial Food Packaging: Potential & Pitfalls

    Directory of Open Access Journals (Sweden)

    BHANU eMALHOTRA

    2015-06-01

    Full Text Available Nowadays food preservation, quality maintenance, and safety are major growing concerns of the food industry. It is evident that over time consumers’ demand for natural and safe food products with stringent regulations to prevent food-borne infectious diseases. Antimicrobial packaging which is thought to be a subset of active packaging and controlled release packaging is one such promising technology which effectively impregnates the antimicrobial into the food packaging film material and subsequently delivers it over the stipulated period of time to kill the pathogenic microorganisms affecting food products thereby increasing the shelf life to severe folds. This paper presents a picture of the recent research on antimicrobial agents that are aimed at enhancing and improving food quality and safety by reduction of pathogen growth and extension of shelf life, in a form of a comprehensive review. Examination of the available antimicrobial packaging technologies is also presented along with their significant impact on food safety. This article entails various antimicrobial agents for commercial applications, as well as the difference between the use of antimicrobials under laboratory scale and real time applications. Development of resistance amongst microorganisms is considered as a future implication of antimicrobials with an aim to come up with actual efficacies in extension of shelf life as well as reduction in bacterial growth through the upcoming and promising use of antimicrobials in food packaging for the forthcoming research down the line.

  9. The Engineered SVA Trans-mobilization Assay.

    Science.gov (United States)

    Bock, Anja; Schumann, Gerald G

    2016-01-01

    Mammalian genomes harbor autonomous retrotransposons coding for the proteins required for their own mobilization, and nonautonomous retrotransposons, such as the human SVA element, which are transcribed but do not have any coding capacity. Mobilization of nonautonomous retrotransposons depends on the recruitment of the protein machinery encoded by autonomous retrotransposons. Here, we summarize the experimental details of SVA trans-mobilization assays which address multiple questions regarding the biology of both nonautonomous SVA elements and autonomous LINE-1 (L1) retrotransposons. The assay evaluates if and to what extent a noncoding SVA element is mobilized in trans by the L1-encoded protein machinery, the structural organization of the resulting marked de novo insertions, if they mimic endogenous SVA insertions and what the roles of individual domains of the nonautonomous retrotransposon for SVA mobilization are. Furthermore, the highly sensitive trans-mobilization assay can be used to verify the presence of otherwise barely detectable endogenously expressed functional L1 proteins via their marked SVA trans-mobilizing activity.

  10. Rapid Active Sampling Package

    Science.gov (United States)

    Peters, Gregory

    2010-01-01

    A field-deployable, battery-powered Rapid Active Sampling Package (RASP), originally designed for sampling strong materials during lunar and planetary missions, shows strong utility for terrestrial geological use. The technology is proving to be simple and effective for sampling and processing materials of strength. Although this originally was intended for planetary and lunar applications, the RASP is very useful as a powered hand tool for geologists and the mining industry to quickly sample and process rocks in the field on Earth. The RASP allows geologists to surgically acquire samples of rock for later laboratory analysis. This tool, roughly the size of a wrench, allows the user to cut away swaths of weathering rinds, revealing pristine rock surfaces for observation and subsequent sampling with the same tool. RASPing deeper (.3.5 cm) exposes single rock strata in-situ. Where a geologist fs hammer can only expose unweathered layers of rock, the RASP can do the same, and then has the added ability to capture and process samples into powder with particle sizes less than 150 microns, making it easier for XRD/XRF (x-ray diffraction/x-ray fluorescence). The tool uses a rotating rasp bit (or two counter-rotating bits) that resides inside or above the catch container. The container has an open slot to allow the bit to extend outside the container and to allow cuttings to enter and be caught. When the slot and rasp bit are in contact with a substrate, the bit is plunged into it in a matter of seconds to reach pristine rock. A user in the field may sample a rock multiple times at multiple depths in minutes, instead of having to cut out huge, heavy rock samples for transport back to a lab for analysis. Because of the speed and accuracy of the RASP, hundreds of samples can be taken in one day. RASP-acquired samples are small and easily carried. A user can characterize more area in less time than by using conventional methods. The field-deployable RASP used a Ni

  11. Insertional Achilles tendinitis and Haglund's deformity.

    Science.gov (United States)

    Kang, Steve; Thordarson, David B; Charlton, Timothy P

    2012-06-01

    Haglund's deformity is an enlargement of the posterosuperior prominence of the calcaneus, which is frequently associated with insertional Achilles tendinitis. To our knowledge, no study has been done successfully correlating the characteristics of a Haglund's deformity with insertional Achilles tendinitis. The purpose of our study was to analyze the characteristics of a Haglund's deformity in patients with and without insertional Achilles tendinitis to see if there was a correlation. The study was a retrospective radiographic review of a single surgeon's patients with insertional Achilles tendinitis from 2005 to 2008. Our study population consisted of 44 patients, 48 heels (22 male, 22 female) with insertional Achilles tendinitis, with a mean age of 52 (range, 23 to 79) years. Our control population consisted of 50 patients (25 males, 25 females) and 50 heels without insertional Achilles tendinitis with a mean age of 55.6 (range, 18 to 89) years. We introduced two new measurements of the Haglund's deformity in this study: the Haglund's deformity height and peak angle. A standing lateral foot or ankle radiograph was analyzed for each patient and the following measurements were made: Haglund deformity height and peak angle; Bohler's angle; Fowler-Philip angle; and parallel pitch sign. We also looked for the presence of calcification in the study group and the length and width of the calcification. Unpaired t-test was used to analyze the measurements between the groups. Ten patients' radiographs were re-measured and correlation coefficients were obtained to assess the reliability of the measuring techniques. For the insertional Achilles tendinitis group, the mean Haglund's deformity height was 9.6 (range, 5.3 to 15.3) mm and the mean Haglund's deformity peak angle was 105 (range, 87 to 123) degrees. Calcification was present in 35 of 48 or (73%) of patients with a mean length of 13.3 (range, 3.2 to 41.9) mm and mean width of 4.5 (range, 1.0 to 10.4) mm. In the control

  12. Prevention policies addressing packaging and packaging waste: Some emerging trends.

    Science.gov (United States)

    Tencati, Antonio; Pogutz, Stefano; Moda, Beatrice; Brambilla, Matteo; Cacia, Claudia

    2016-10-01

    Packaging waste is a major issue in several countries. Representing in industrialized countries around 30-35% of municipal solid waste yearly generated, this waste stream has steadily grown over the years even if, especially in Europe, specific recycling and recovery targets have been fixed. Therefore, an increasing attention starts to be devoted to prevention measures and interventions. Filling a gap in the current literature, this explorative paper is a first attempt to map the increasingly important phenomenon of prevention policies in the packaging sector. Through a theoretical sampling, 11 countries/states (7 in and 4 outside Europe) have been selected and analyzed by gathering and studying primary and secondary data. Results show evidence of three specific trends in packaging waste prevention policies: fostering the adoption of measures directed at improving packaging design and production through an extensive use of the life cycle assessment; raising the awareness of final consumers by increasing the accountability of firms; promoting collaborative efforts along the packaging supply chains. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Microbead agglutination based assays

    KAUST Repository

    Kodzius, Rimantas

    2013-01-21

    We report a simple and rapid room temperature assay for point-of-care (POC) testing that is based on specific agglutination. Agglutination tests are based on aggregation of microbeads in the presence of a specific analyte thus enabling the macroscopic observation. Such tests are most often used to explore antibody-antigen reactions. Agglutination has been used for protein assays using a biotin/streptavidin system as well as a hybridization based assay. The agglutination systems are prone to selftermination of the linking analyte, prone to active site saturation and loss of agglomeration at high analyte concentrations. We investigated the molecular target/ligand interaction, explaining the common agglutination problems related to analyte self-termination, linkage of the analyte to the same bead instead of different microbeads. We classified the agglutination process into three kinds of assays: a two- component assay, a three-component assay and a stepped three- component assay. Although we compared these three kinds of assays for recognizing DNA and protein molecules, the assay can be used for virtually any molecule, including ions and metabolites. In total, the optimized assay permits detecting analytes with high sensitivity in a short time, 5 min, at room temperature. Such a system is appropriate for POC testing.

  14. Aspects of insertion in random trees

    NARCIS (Netherlands)

    Bagchi, Arunabha; Reingold, E.M.

    1982-01-01

    A method formulated by Yao and used by Brown has yielded bounds on the fraction of nodes with specified properties in trees bult by a sequence of random internal nodes in a random tree built by binary search and insertion, and show that in such a tree about bounds better than those now known. We

  15. SOLVENTLESS MIGRATORY-INSERTION REACTIONS OF ...

    African Journals Online (AJOL)

    Preferred Customer

    Solventless migratory-insertion reactions of substituted cyclopentadienyl iron complexes. Bull. Chem. Soc. Ethiop. 2009, 23(3). 401. A homemade glass heating device was pre-calibrated with crystals of known melting points. An optical microscope fitted with a JVC Digital Camera was used to monitor the reaction, performed ...

  16. Intraoperative precautionary insertion of external ventricular ...

    African Journals Online (AJOL)

    Only eight cases (19%) needed permanent CSF shunting, seven of which were ependymomas and medulloblastomas. None of the cases in this series acquired any EVD related infection, nor did those who required subsequent permanent CSF diversion. Conclusion: Intra-operative insertion of EVD catheter during surgery ...

  17. Angiotensin Converting Enzyme Insertion/Deletion Gene ...

    African Journals Online (AJOL)

    Erah

    Pharmacotherapy Group,. Faculty of Pharmacy, University of Benin,. Benin City, 300001 Nigeria. All rights reserved. Available online at http://www.tjpr.org. Research Article. Angiotensin Converting Enzyme Insertion/Deletion. Gene Polymorphism: An Observational Study among. Diabetic Hypertensive Subjects in Malaysia.

  18. Atomistic Galois insertions for flow sensitive integrity

    DEFF Research Database (Denmark)

    Nielson, Flemming; Nielson, Hanne Riis

    2017-01-01

    and to obtain full automation we shall explore the over-approximating nature of static analysis. We demonstrate that the use of atomistic Galois insertions constitutes a stable framework in which to obtain sound and fully automatic enforcement of flow sensitive integrity. The framework is illustrated...

  19. Anaesthetic management for ventriculoperitoneal shunt insertion in ...

    African Journals Online (AJOL)

    http://creativecommons.org/licenses/by-nc/3.0. Anaesthetic management for ventriculoperitoneal shunt insertion in an infant with Dandy–Walker Syndrome. Alastair Wayne Moodleya*, Steven Nelac , Eduard Oosthuizenac and Christina Lundgrenbc. aDepartment of Anaesthesia, Charlotte Maxeke Johannesburg Academic ...

  20. Evaluation of apicultural characteristics of first-year colonies initiated from packaged honey bees (Hymenoptera: Apidae).

    Science.gov (United States)

    Strange, James P; Calderone, Nicholas W

    2009-04-01

    We evaluated the performance of six named types of package honey bees, Apis mellifera L (Hymenoptera: Apidae), from four commercial producers. We examined the effects of levels of the parasitic mite Varroa destructor Anderson & Trueman, the endoparasitic mite Acarapis woodi (Rennie), the gut parasite Nosema (species not determined) in samples from bees in 48 packages, and levels of adult drones in the same packages on corresponding levels of those same traits in the fall in colonies that developed from those 48 packages. After package installation, we measured the rate of queen failure, the removal of freeze-killed brood (an assay to assess hygienic behavior), varroa-sensitive hygiene, and short-term weight gain in all colonies. We examined the correlations among these traits and the effect of initial package conditions and package-type on the expression of these traits. In general, differences among sources were not significant, except that we did observe significant differences in the proportion of mite infected worker brood in the fall. There was no significant difference in weight gain in colonies established from nosema-infected packages versus those established from noninfected packages. Freeze-killed hygienic behavior and varroa-sensitive hygienic behavior were positively correlated, suggesting that both traits could be selected simultaneously. Neither trait was correlated with colony weight gain, suggesting that both traits could be selected without compromising honey production.

  1. 9 CFR 381.144 - Packaging materials.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Packaging materials. 381.144 Section... Packaging materials. (a) Edible products may not be packaged in a container which is composed in whole or in... to health. All packaging materials must be safe for the intended use within the meaning of section...

  2. A Pre- and Post-Evaluation of Integrating Sustainability Curriculum by Inserting Okala Modules into an Interior Design Materials and Methods Course

    Science.gov (United States)

    Schneiderman, Deborah; Freihoefer, Kara

    2012-01-01

    Purpose: The purpose of this paper is to examine the integration of Okala curriculum into Interior Design coursework. Okala, as a teaching package, is utilized extensively in industrial design education. However, this study examines the expansion and insertion of Okala modules in an existing interior design curriculum. The Okala modules included…

  3. Consolidation and disposal of PWR fuel inserts

    Energy Technology Data Exchange (ETDEWEB)

    Wakeman, B.H. (Virginia Electric and Power Co., Glen Allen, VA (United States))

    1992-08-01

    Design and licensing of the Surry Power Station Independent Spent Fuel Storage Installation was initiated in 1982 by Virginia Power as part of a comprehensive strategy to increase spent fuel storage capacity at the Station. Designed to use large, metal dry storage casks, the Surry Installation will accommodate 84 such casks with a total storage capacity of 811 MTU of spent pressurized water reactor fuel assemblies. Virginia Power provided three storage casks for testing at the Idaho National Engineerinq Laboratory's Test Area North and the testing results have been published by the Electric Power Research Institute. Sixty-nine spent fuel assemblies were transported in truck casks from the Surry Power Station to Test Area North for testing in the three casks. Because of restrictions imposed by the cask testing equipment at Test Area North, the irradiated insert components stored in these fuel assemblies at Surry were removed prior to transport of the fuel assemblies. Retaining these insert components proved to be a problem because of a shortage of spent fuel assemblies in the spent fuel storage pool that did not already contain insert components. In 1987 Virginia Power contracted with Chem-Nuclear Systems, Inc. to process and dispose of 136 irradiated insert components consisting of 125 burnable poison rod assemblies, 10 thimble plugging devices and 1 part-length rod cluster control assembly. This work was completed in August and September 1987, culminating in the disposal at the Barnwell, SC low-level radioactive waste facility of two CNS 3-55 liners containing the consolidated insert components.

  4. Absolute nuclear material assay

    Science.gov (United States)

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2012-05-15

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  5. Absolute nuclear material assay

    Science.gov (United States)

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2010-07-13

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  6. Nanocellulose in green food packaging.

    Science.gov (United States)

    Vilarinho, Fernanda; Sanches Silva, Ana; Vaz, M Fátima; Farinha, José Paulo

    2017-01-26

    The development of packaging materials with new functionalities and lower environmental impact is now an urgent need of our society. On one hand, the shelf-life extension of packaged products can be an answer to the exponential increase of worldwide demand for food. On the other hand, uncertainty of crude oil prices and reserves has imposed the necessity to find raw materials to replace oil-derived polymers. Additionally, consumers' awareness toward environmental issues increasingly pushes industries to look with renewed interest to "green" solutions. In response to these issues, numerous polymers have been exploited to develop biodegradable food packaging materials. Although the use of biopolymers has been limited due to their poor mechanical and barrier properties, these can be enhanced by adding reinforcing nanosized components to form nanocomposites. Cellulose is probably the most used and well-known renewable and sustainable raw material. The mechanical properties, reinforcing capabilities, abundance, low density, and biodegradability of nanosized cellulose make it an ideal candidate for polymer nanocomposites processing. Here we review the potential applications of cellulose based nanocomposites in food packaging materials, highlighting the several types of biopolymers with nanocellulose fillers that have been used to form bio-nanocomposite materials. The trends in nanocellulose packaging applications are also addressed.

  7. The reduction of packaging waste

    Energy Technology Data Exchange (ETDEWEB)

    Raney, E.A.; Hogan, J.J.; McCollom, M.L.; Meyer, R.J.

    1994-04-01

    Nationwide, packaging waste comprises approximately one-third of the waste disposed in sanitary landfills. the US Department of Energy (DOE) generated close to 90,000 metric tons of sanitary waste. With roughly one-third of that being packaging waste, approximately 30,000 metric tons are generated per year. The purpose of the Reduction of Packaging Waste project was to investigate opportunities to reduce this packaging waste through source reduction and recycling. The project was divided into three areas: procurement, onsite packaging and distribution, and recycling. Waste minimization opportunities were identified and investigated within each area, several of which were chosen for further study and small-scale testing at the Hanford Site. Test results, were compiled into five ``how-to`` recipes for implementation at other sites. The subject of the recipes are as follows: (1) Vendor Participation Program; (2) Reusable Containers System; (3) Shrink-wrap System -- Plastic and Corrugated Cardboard Waste Reduction; (4) Cardboard Recycling ; and (5) Wood Recycling.

  8. Package power stations for export

    Energy Technology Data Exchange (ETDEWEB)

    1985-01-01

    The cheap and efficient generation of power is an essential requirement for the success and prosperity of any community and is especially important to third world countries. It is therefore logical that the more technologically advanced nations should seek to produce power stations for the developing countries. Power plant can now be designed into a packaged form that may be readily exported and commissioned. This valuable and interesting collection of papers were originally presented at a seminar organised by the Power Industries Division of the Institution of Mechanical Engineers. Topics considered include the developing world market for packaged power stations using indigenous fuels; multi-fuel systems for power generation; packaging, modularisation, and containerisation of equipment for power boilers for export; compact coal-fired industrial plant; rural woodburning power stations; biomass gasification based power generation technology and potential; gas fed reciprocating engine development; packaged heavy duty gas turbines for power generation; and criteria for assessing the appropriateness of package power technologies in developing countries.

  9. Package inspection using inverse diffraction

    Science.gov (United States)

    McAulay, Alastair D.

    2008-08-01

    More efficient cost-effective hand-held methods of inspecting packages without opening them are in demand for security. Recent new work in TeraHertz sources,1 millimeter waves, presents new possibilities. Millimeter waves pass through cardboard and styrofoam, common packing materials, and also pass through most materials except those with high conductivity like metals which block light and are easily spotted. Estimating refractive index along the path of the beam through the package from observations of the beam passing out of the package provides the necessary information to inspect the package and is a nonlinear problem. So we use a generalized linear inverse technique that we first developed for finding oil by reflection in geophysics.2 The computation assumes parallel slices in the packet of homogeneous material for which the refractive index is estimated. A beam is propagated through this model in a forward computation. The output is compared with the actual observations for the package and an update computed for the refractive indices. The loop is repeated until convergence. The approach can be modified for a reflection system or to include estimation of absorption.

  10. Standardised Packaging of Tobacco Products Evidence Review

    OpenAIRE

    Department of Health (Ireland)

    2014-01-01

    The current report reviews the scientific evidence on standardised or “plain” packaging, and the extent to which plain packaging regulations would help Ireland to achieve its tobacco control objectives.   Plain packaging is a form of marketing restriction that prohibits the use of logos, colours, brand images and promotional information on tobacco packaging. Under plain packaging regulations, the colour of the pack is uniform across different brands and varieties. Regulations ma...

  11. Advanced organics for electronic substrates and packages

    CERN Document Server

    Fletcher, Andrew E

    1992-01-01

    Advanced Organics for Electronic Substrates and Packages provides information on packaging, which is one of the most technologically intensive activities in the electronics industry. The electronics packaging community has realized that while semiconductor devices continue to be improved upon for performance, cost, and reliability, it is the interconnection or packaging of these devices that will limit the performance of the systems. Technology must develop packaging for transistor chips, with high levels of performance and integration providing cooling, power, and interconnection, and yet pre

  12. Semiconductor packaging materials interaction and reliability

    CERN Document Server

    Chen, Andrea

    2012-01-01

    In semiconductor manufacturing, understanding how various materials behave and interact is critical to making a reliable and robust semiconductor package. Semiconductor Packaging: Materials Interaction and Reliability provides a fundamental understanding of the underlying physical properties of the materials used in a semiconductor package. The book focuses on an important step in semiconductor manufacturing--package assembly and testing. It covers the basics of material properties and explains how to determine which behaviors are important to package performance. The authors also discuss how

  13. The paradox of packaging optimization – a characterization of packaging source reduction in the Netherlands

    NARCIS (Netherlands)

    van Sluisveld, M.A.E.; Worrell, E.|info:eu-repo/dai/nl/106856715

    2013-01-01

    The European Council Directive 94/62/EC for Packaging and Packaging Waste requires that Member States implement packaging waste prevention measures. However, consumption and subsequently packaging waste figures are still growing annually. It suggests that policies to accomplish packaging waste

  14. Human transposon insertion profiling: Analysis, visualization and identification of somatic LINE-1 insertions in ovarian cancer

    Science.gov (United States)

    Tang, Zuojian; Steranka, Jared P.; Ma, Sisi; Grivainis, Mark; Rodić, Nemanja; Huang, Cheng Ran Lisa; Shih, Ie-Ming; Wang, Tian-Li; Fenyö, David

    2017-01-01

    Mammalian genomes are replete with interspersed repeats reflecting the activity of transposable elements. These mobile DNAs are self-propagating, and their continued transposition is a source of both heritable structural variation as well as somatic mutation in human genomes. Tailored approaches to map these sequences are useful to identify insertion alleles. Here, we describe in detail a strategy to amplify and sequence long interspersed element-1 (LINE-1, L1) retrotransposon insertions selectively in the human genome, transposon insertion profiling by next-generation sequencing (TIPseq). We also report the development of a machine-learning–based computational pipeline, TIPseqHunter, to identify insertion sites with high precision and reliability. We demonstrate the utility of this approach to detect somatic retrotransposition events in high-grade ovarian serous carcinoma. PMID:28096347

  15. Comparison of conventional Injection Mould Inserts to Additively Manufactured Inserts using Life Cycle Assessment

    DEFF Research Database (Denmark)

    Hofstätter, Thomas; Bey, Niki; Mischkot, Michael

    2016-01-01

    Polymer Additive Manufacturing can be used to produce soft tooling inserts for injection moulding. Compared to conventional tooling, the energy and time consumption during production are significantly lower. As the life time of such inserts is significantly shorter than the life time of traditional...... of their potential environmental impact and yield throughout the development and pilot phase. Insert geometry is particularly advantageous for pilot production and small production sizes. In this research, Life Cycle Assessment is used to compare the environmental impact of soft tooling by Additive Manufacturing...... (using Digital Light Processing) and three traditional methods for the manufacture of inserts (milling of brass, steel, and aluminium) for injection moulds during the pre-production phase....

  16. Flexible packaging for PV modules

    Science.gov (United States)

    Dhere, Neelkanth G.

    2008-08-01

    Economic, flexible packages that provide needed level of protection to organic and some other PV cells over >25-years have not yet been developed. However, flexible packaging is essential in niche large-scale applications. Typical configuration used in flexible photovoltaic (PV) module packaging is transparent frontsheet/encapsulant/PV cells/flexible substrate. Besides flexibility of various components, the solder bonds should also be flexible and resistant to fatigue due to cyclic loading. Flexible front sheets should provide optical transparency, mechanical protection, scratch resistance, dielectric isolation, water resistance, UV stability and adhesion to encapsulant. Examples are Tefzel, Tedlar and Silicone. Dirt can get embedded in soft layers such as silicone and obscure light. Water vapor transmittance rate (WVTR) of polymer films used in the food packaging industry as moisture barriers are ~0.05 g/(m2.day) under ambient conditions. In comparison, light emitting diodes employ packaging components that have WVTR of ~10-6 g/(m2.day). WVTR of polymer sheets can be improved by coating them with dense inorganic/organic multilayers. Ethylene vinyl acetate, an amorphous copolymer used predominantly by the PV industry has very high O2 and H2O diffusivity. Quaternary carbon chains (such as acetate) in a polymer lead to cleavage and loss of adhesional strength at relatively low exposures. Reactivity of PV module components increases in presence of O2 and H2O. Adhesional strength degrades due to the breakdown of structure of polymer by reactive, free radicals formed by high-energy radiation. Free radical formation in polymers is reduced when the aromatic rings are attached at regular intervals. This paper will review flexible packaging for PV modules.

  17. Plastic food packaging and health

    OpenAIRE

    Raika Durusoy; Ali Osman Karababa

    2011-01-01

    Plastics have a wide usage in our daily lives. One of their uses is for food packaging and food containers. The aim of this review is to introduce different types of chemicals that can leach from food packaging plastics into foods and cause human exposure and to mention their effects on health. The types of plastics were reviewed under the 13 headings in Turkish Codex Alimentarius and plastics recycling symbols were provided to enable the recognition of the type of plastic when applicable. Ch...

  18. GNS-12 Packaging design criteria

    Energy Technology Data Exchange (ETDEWEB)

    Clements, E.P., Westinghouse Hanford

    1996-07-24

    The purpose of this Packaging Design Criteria (PDC) is to provide criteria for the Safety Analysis Report for Packaging (SARP)(Onsite). The SARP provides the evaluation to demonstrate that the onsite transportation safety criteria are met for the transport and storage of the 324 Building vitrified encapsulated material in the GNS-12 cask. In this application, the approved PDC provides a formal set of standards for the payload requirements, and guidance for the current cask transport configuration and a revised storage seal and primary lid modification design.

  19. Family of Packaged Water/Packaged Water System

    Science.gov (United States)

    1994-03-01

    equipment were surveyed. These companies were selected from: a. Thomas Register - Pharmaceutical , Blood Processing Equipment, and Intravenous Equipment...Engineering Center, ASTM- CCM , Fort Lee, VA. 4. U.S. Army Quartermaster Center and School. 1992. Draft Study Plan for the Packaged Water System

  20. Plasmids containing insertion elements are potential transposons.

    OpenAIRE

    Ohtsubo, E; Zenilman, M; Ohtsubo, H

    1980-01-01

    We studied in vivo recombination between the plasmid pHS1, a temperature-sensitive replication mutant carrying tetracycline resistance, and pSM1, a small plasmid carrying one copy of the insertion element IS1. Recombinant plasmids were found by selection for tetracycline resistance at 42 degrees C. Their formation was independent of recA function. Analysis of the physical structures of various recombinant DNA molecules with electron microscopy and restriction endonucleases revealed that pSMI ...

  1. Aspergillus arachnoiditis post intrathecal baclofen pump insertion.

    Science.gov (United States)

    Vivek, V; Kavar, B; Hogg, M; Eisen, D P; Butzkueven, H

    2013-08-01

    This report describes an unusual fungal infection of an intrathecal baclofen pump which, to our knowledge, has not been reported previously. We describe a 39-year-old man with severe lower limb spasticity due to secondary progressive multiple sclerosis that was managed with insertion of an intrathecal baclofen pump. He subsequently presented with distinct neurological decline secondary to an intrathecal baclofen pump infection with Aspergillus terreus. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  2. Comparison of Insertional RNA Editing in Myxomycetes

    Science.gov (United States)

    Chen, Cai; Frankhouser, David; Bundschuh, Ralf

    2012-01-01

    RNA editing describes the process in which individual or short stretches of nucleotides in a messenger or structural RNA are inserted, deleted, or substituted. A high level of RNA editing has been observed in the mitochondrial genome of Physarum polycephalum. The most frequent editing type in Physarum is the insertion of individual Cs. RNA editing is extremely accurate in Physarum; however, little is known about its mechanism. Here, we demonstrate how analyzing two organisms from the Myxomycetes, namely Physarum polycephalum and Didymium iridis, allows us to test hypotheses about the editing mechanism that can not be tested from a single organism alone. First, we show that using the recently determined full transcriptome information of Physarum dramatically improves the accuracy of computational editing site prediction in Didymium. We use this approach to predict genes in the mitochondrial genome of Didymium and identify six new edited genes as well as one new gene that appears unedited. Next we investigate sequence conservation in the vicinity of editing sites between the two organisms in order to identify sites that harbor the information for the location of editing sites based on increased conservation. Our results imply that the information contained within only nine or ten nucleotides on either side of the editing site (a distance previously suggested through experiments) is not enough to locate the editing sites. Finally, we show that the codon position bias in C insertional RNA editing of these two organisms is correlated with the selection pressure on the respective genes thereby directly testing an evolutionary theory on the origin of this codon bias. Beyond revealing interesting properties of insertional RNA editing in Myxomycetes, our work suggests possible approaches to be used when finding sequence motifs for any biological process fails. PMID:22383871

  3. Thought insertion, cognitivism, and inner space.

    Science.gov (United States)

    Thornton, Tim

    2002-08-01

    Whatever its underlying causes, even the description of the phenomenon of thought insertion, of the content of the delusion, presents difficulty. It may seem that the best hope of a description comes from a broadly cognitivist approach to the mind which construes content-laden mental states as internal mental representations within what is literally an inner space: the space of the brain or nervous system. Such an approach objectifies thoughts in a way which might seem to hold out the prospect of describing the ''alienated'' relation to one's own thoughts that seems to be present in thought insertion.1 Firstly, I examine the general structure of cognitivist accounts of intentional or content-laden mental states. I raise the general difficulty of explaining how free-standing, and thus world-independent, inner states can still have bearing on the outer world. Secondly, I briefly examine Frith's model for explaining thought insertion and other passivity phenomena by postulating a failure of an internal monitoring mechanism of inner states. I question what account can be given of non-pathological cases and raise two specific objects. Cognitivist accounts of the mind face a general, and possibly insuperable, challenge: explaining the intentionality of mental states in non-intentional, nonquestion-begging terms. There have so far been no satisfactory solutions. Cognitivist accounts of passivity phenomena in terms of a failure of internal monitoring face two objections. Firstly, accounting for non-pathological cases generates an infinite regress. Secondly, no account can be given of the paradoxical nature of utterances of the form of Moore's paradox: ''it is raining but I do not believe it''. A cognitivist approach presents an alienated account of thought in normal, non-pathological cases and is no help in accounting for thought insertion.

  4. Ninety-Nine Is Not Enough: Molecular Characterization of Inhibitor-Resistant Human Immunodeficiency Virus Type 1 Protease Mutants with Insertions in the Flap Region

    Energy Technology Data Exchange (ETDEWEB)

    Koiek, Milan; Saskova, Klara Grantz; Rezaova, Pavlina; Brynda, Jii; van Maarseveen, Noortje M.; De Jong, Dorien; Boucher, Charles A.; Kagan, Ron M.; Nijhuis, Monique; Konvalinka, Jan (Quest); (Charles U); (Utrecht)

    2008-07-21

    While the selection of amino acid insertions in human immunodeficiency virus (HIV) reverse transcriptase (RT) is a known mechanism of resistance against RT inhibitors, very few reports on the selection of insertions in the protease (PR) coding region have been published. It is still unclear whether these insertions impact protease inhibitor (PI) resistance and/or viral replication capacity. We show that the prevalence of insertions, especially between amino acids 30 to 41 of HIV type 1 (HIV-1) PR, has increased in recent years. We identified amino acid insertions at positions 33 and 35 of the PR of HIV-1-infected patients who had undergone prolonged treatment with PIs, and we characterized the contribution of these insertions to viral resistance. We prepared the corresponding mutated, recombinant PR variants with or without insertions at positions 33 and 35 and characterized them in terms of enzyme kinetics and crystal structures. We also engineered the corresponding recombinant viruses and analyzed the PR susceptibility and replication capacity by recombinant virus assay. Both in vitro methods confirmed that the amino acid insertions at positions 33 and 35 contribute to the viral resistance to most of the tested PIs. The structural analysis revealed local structural rearrangements in the flap region and in the substrate binding pockets. The enlargement of the PR substrate binding site together with impaired flap dynamics could account for the weaker inhibitor binding by the insertion mutants. Amino acid insertions in the vicinity of the binding cleft therefore represent a novel mechanism of HIV resistance development.

  5. Experimental insertions made of two symmetric triplets

    CERN Document Server

    D'Amico, T E

    1998-01-01

    The reported study is based on the analytical treatment developed for an experimental collider insertion made of two symmetric triplets,the inner triplet located near the interaction point (IP) and th e outer triplet preceding a regular lattice. These two triplets are assumed to be symmetric in their geometry and quadrupole strengths, but not in their Twiss parameters. The method is applied to an i nsertion of the type of an experimental LHC insertion. The drift between the IP and the first quadrupole is fixed and the inner triplet is constrained to achieve a beta-crossing with equal and opposit e slopes (alpha-values) in the two planes. The outer triplet acts then as a FODO transformer from beta-crossing to beta-crossing in order to match the lattice. The analysis provides in a given paramet er interval all the existing solutions for the distance between triplets and the total insertion length, as functions of one gradient and the quadrupole separation in the inner triplet. The variation of the quadrupole st...

  6. Intelligent food packaging - research and development

    Directory of Open Access Journals (Sweden)

    Renata Dobrucka

    2015-03-01

    Full Text Available Packaging also fosters effective marketing of the food through distribution and sale channels. It is of the utmost importance to optimize the protection of the food, a great quality and appearance - better than typical packaged foods. In recent years, intelligent packaging became very popular. Intelligent packaging is becoming more and more widely used for food products. Application of this type of solution contributes to improvement of the quality consumer life undoubtedly. Intelligent packaging refers to a package that can sense environmental changes, and in turn, informs the users about the changes. These packaging systems contain devices that are capable of sensing and providing information about the functions and properties of the packaged foods. Also, this paper will review intelligent packaging technologies and describe different types of indicators (time-temperature indicators, freshness indicators.

  7. Effects of freezing on tissue factor activity in a thromboelastography assay.

    Science.gov (United States)

    Scruggs, Jennifer L; Flatland, Bente; Reed, Ann

    2014-09-01

    Human recombinant tissue factor (TF) can be used to activate viscoelastic coagulation assays. Although the package insert indicates that TF should not be frozen, published scientific data are not available. Ability to store frozen aliquots of TF would increase laboratory efficiency and decrease costs associated with performing TF-activated assays. The objectives of this study were to determine the effects of freezing and storage time on TF's ability to activate commercially available quality control material in thromboelastography (TEG). TF was diluted and frozen at -20°C and -70°C for 72 hours, one week, 2 weeks, 3 months, and 6 months, and used for TEG after thawing. TF activation of control material was also assessed after TF storage at room temperature for 0, 24, and 48 hours. Time to fibrin formation (R), rate of clot formation (K and angle α), and clot strength (MA) were measured, and ANOVA used to identify differences. There were no significant differences in mean α and MA regardless of storage time or temperature. Means for R were not significantly increased at any time point after storage at room temperature or -70°C, but significant increases in mean R were observed after storage at -20°C starting after one week and continuing up to 6 months. TF can be stored at room temperature for at least 48 hours, stored at -20°C for 72 hours, and stored at -70°C for up to 6 months without significant loss of activity for TEG. © 2014 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.

  8. Cognitive-behavioral interventions for IV insertion pain.

    Science.gov (United States)

    Jacobson, Ann F

    2006-12-01

    INSERTION OF AN IV CATHETER is a commonly performed and painful procedure. The use of cognitive-behavioral interventions (CBIs) may decrease pain by diverting the patient's attention to stimuli other than pain. THIS RANDOMIZED, CONTROLLED TRIAL examined the effect of three CBIs--music, kaleidoscope, and guided imagery--on IV insertion pain in 324 patients. NO STATISTICALLY SIGNIFICANT differences in IV insertion pain were found among the treatment and control groups or between choosing versus being assigned a CBI. Insertion attempts were more difficult in women, and insertion difficulty was correlated with pain intensity and pain distress. Pain intensity was related to insertion site and catheter gauge.

  9. Assessing Information on Food Packages

    DEFF Research Database (Denmark)

    Clement, Jesper; Smith, Viktor; Zlatev, Jordan

    2017-01-01

    Purpose: This paper presents an experimental study which aims at assessing the potentially misleading effect of graphic elements on food packaging. We call these elements potentially misleading elements (PMEs) as they can give customers false expectations. They are either (a) highlighted numerical...

  10. Annual Symposium in Electronics Packaging

    CERN Document Server

    1991-01-01

    Each May, the Continuing Education Division of the T.J.Watson School of Engineering, Applied Science and Technology at the State University of New York at Binghamton sponsors an Annual Symposium in Electronics Packaging in cooperation with local professional societies (IEEE, ASME, SME, IEPS) and UnlPEG (the University-Industry Partnership for Economic Growth.) Each volume of this Electronics Packaging Forum series is based on the the preceding Symposium, with Volume Two based on the 1990 presentations. The Preface to Volume One included a brief definition of the broad scope of the electronics packaging field with some comments on why it has recently assumed such a more prominent priority for research and development. Those remarks will not be repeated here; at this point it is assumed that the reader is a professional in the packaging field, or possibly a student of one of the many academic disciplines which contribute to it. It is worthwhile repeating the series objectives, however, so the reader will be cle...

  11. The ssWavelets package

    Science.gov (United States)

    Jeffrey H. Gove

    2017-01-01

    This package adds several classes, generics and associated methods as well as a few various functions to help with wavelet decomposition of sampling surfaces generated using sampSurf. As such, it can be thought of as an extension to sampSurf for wavelet analysis.

  12. Food Nanotechnology - Food Packaging Applications

    Science.gov (United States)

    Astonishing growth in the market for nanofoods is predicted in the future, from the current market of $2.6 billion to $20.4 billion in 2010. The market for nanotechnology in food packaging alone is expected to reach $360 million in 2008. In large part, the impetus for this predicted growth is the ...

  13. Packaging Aspects of Photodetector Modules for 100 Gbit/s Ethernet Applications

    DEFF Research Database (Denmark)

    Jiang, Chenhui; Mekonnen, G.G.; Krozer, Viktor

    2008-01-01

    Packaging is a major problem at millimetre-wave frequencies approaching 100 GHz. In this paper we present that insertion losses in a multi-chip module (MCM) can be less IL ...-backed coplanar waveguides (CBCPWs) with vias is accurately analyzed using 3D electromagnetic (EM) simulation over a wide frequency range. Patch antenna mode resonances are identified as a major origin of resonances in simulated and measured transmission characteristics of the CBCPW with vias. Based on EM...

  14. Hanford Site radioactive hazardous materials packaging directory

    Energy Technology Data Exchange (ETDEWEB)

    McCarthy, T.L.

    1995-12-01

    The Hanford Site Radioactive Hazardous Materials Packaging Directory (RHMPD) provides information concerning packagings owned or routinely leased by Westinghouse Hanford Company (WHC) for offsite shipments or onsite transfers of hazardous materials. Specific information is provided for selected packagings including the following: general description; approval documents/specifications (Certificates of Compliance and Safety Analysis Reports for Packaging); technical information (drawing numbers and dimensions); approved contents; areas of operation; and general information. Packaging Operations & Development (PO&D) maintains the RHMPD and may be contacted for additional information or assistance in obtaining referenced documentation or assistance concerning packaging selection, availability, and usage.

  15. SMART PACKAGING FOR FOOD PRESERVATION

    Directory of Open Access Journals (Sweden)

    Raquel Rodríguez-Sauceda

    2014-07-01

    Full Text Available One of the biggest challenges of the food industry is the preservation of its products, that is, to prevent them from being attacked by microorganisms that decompose them hauling economic losses and severe health damage to the consumer. Today, competition in the food industry is very high and any company that does not offer the quality products is doomed to fail. Consumers demand more and the industry still stands offering what is asked: quality, security and safety. The package, in addition to fulfilling its core functions is becoming a means of sophisticated interactions with content and a record of relevant information for both the end consumer and intermediate players in the value chain and concepts are born of active and intelligent packaging. A smart container is defined as a system that monitors the condition of the packaged product, being able to register and provide information about product quality or condition of the container, showing the possible "abnormal" practices that have suffered the product or the container during the entire supply chain, such as transportation or storage. These systems monitor the mechanisms of altered food due to physiological, chemical and biological processes that respond and communicate changes in the status of the product as time-temperature, Oxygen, Carbon dioxide, microbial growth, etc. There are different types of smart packaging such as time-temperature indicators, color indicators, indicators of pathogens and indicators of leaks, to name a few. Through literature review, arguments that demonstrate the usefulness and necessity of the use of smart packaging to preserve the quality and safety of the product it contains, from manufacturing to the time it is used by consumers were found, as these besides communicating or providing information about their state, acting as a marketing tool.

  16. Plastic food packaging and health

    Directory of Open Access Journals (Sweden)

    Raika Durusoy

    2011-02-01

    Full Text Available Plastics have a wide usage in our daily lives. One of their uses is for food packaging and food containers. The aim of this review is to introduce different types of chemicals that can leach from food packaging plastics into foods and cause human exposure and to mention their effects on health. The types of plastics were reviewed under the 13 headings in Turkish Codex Alimentarius and plastics recycling symbols were provided to enable the recognition of the type of plastic when applicable. Chemicals used during the production and that can cause health risks are investigated under the heading of the relevant type of plastic. The most important chemicals from plastic food packaging that can cause toxicity are styrene, 1,3-butadiene, melamine, formaldehyde, acrylamide, di-2-ethylhexyl phthalate, di-2-ethylhexyl adipate, vinyl chloride and bisphenol A. These chemicals have endocrine disrupting, carcinogenic and/or development disrupting effects. These chemicals may leach into foods depending on the chemical properties of the plastic or food, temperature during packaging, processing and storage, exposure to UV and duration of storage. Contact with fatty/oily or acidic foods, heating of the food inside the container, or drinking hot drinks from plastic cups, use of old and scratched plastics and some detergents increase the risk of leaching. The use of plastic containers and packaging for food and beveradges should be avoided whenever possible and when necessary, less harmful types of plastic should be preferred. [TAF Prev Med Bull 2011; 10(1.000: 87-96

  17. Cross-packaging of genetically distinct mouse and primate retroviral RNAs

    Directory of Open Access Journals (Sweden)

    Jaballah Soumeya

    2009-07-01

    Full Text Available Abstract Background The mouse mammary tumor virus (MMTV is unique from other retroviruses in having multiple viral promoters, which can be regulated by hormones in a tissue specific manner. This unique property has lead to increased interest in studying MMTV replication with the hope of developing MMTV based vectors for human gene therapy. However, it has recently been reported that related as well as unrelated retroviruses can cross-package each other's genome raising safety concerns towards the use of candidate retroviral vectors for human gene therapy. Therefore, using a trans complementation assay, we looked at the ability of MMTV RNA to be cross-packaged and propagated by an unrelated primate Mason-Pfizer monkey virus (MPMV that has intracellular assembly process similar to that of MMTV. Results Our results revealed that MMTV and MPMV RNAs could be cross-packaged by the heterologous virus particles reciprocally suggesting that pseudotyping between two genetically distinct retroviruses can take place at the RNA level. However, the cross-packaged RNAs could not be propagated further indicating a block at post-packaging events in the retroviral life cycle. To further confirm that the specificity of cross-packaging was conferred by the packaging sequences (ψ, we cloned the packaging sequences of these viruses on expression plasmids that generated non-viral RNAs. Test of these non-viral RNAs confirmed that the reciprocal cross-packaging was primarily due to the recognition of ψ by the heterologous virus proteins. Conclusion The results presented in this study strongly argue that MPMV and MMTV are promiscuous in their ability to cross-package each other's genome suggesting potential RNA-protein interactions among divergent retroviral RNAs proposing that these interactions are more complicated than originally thought. Furthermore, these observations raise the possibility that MMTV and MPMV genomes could also co-package providing substrates for

  18. [Efficient packaging retrovirus and construction of transgenic chicken technical platform].

    Science.gov (United States)

    Man, Chaolai; Zhang, Qing; Chen, Yan; Zhu, Dahai

    2007-10-01

    Transgenic chicken and oviduct bioreactor are growing to be one of the hotspot of scientific study in the field of biology. The most successful method of producing transgenic chicken is pseudotyped retrovirus vector system, but no one has reported the production of transgenic chicken by retrovirus system recently in our country. In order to accelerate our study in this field, we introduced the relevant technical methods such as packaging retrovirus and vesicular stomatitis virus G glycoprotein (VSV-G) pseudotyped retrovirus, optimizing the conditions of packaging retrovirus, concentrating VSV-G pseudotyped retrovirus, helper virus assays, and microinjection of retrovirus. Furthermore, we successfully conducted in vivo study for detecting the marker gene EGFP of chicken embryo as well as in vitro study for detecting that gene of chicken embryo myoblast (CFM), thus we have provided an applied technical platform for studies of transgenic chicken in the future.

  19. The NF1 gene contains hotspots for L1 endonuclease-dependent de novo insertion.

    Directory of Open Access Journals (Sweden)

    Katharina Wimmer

    2011-11-01

    Full Text Available Long interspersed (L1 and Alu elements are actively amplified in the human genome through retrotransposition of their RNA intermediates by the -100 still retrotranspositionally fully competent L1 elements. Retrotransposition can cause inherited disease if such an element is inserted near or within a functional gene. Using direct cDNA sequencing as the primary assay for comprehensive NF1 mutation analysis, we uncovered in 18 unrelated index patients splicing alterations not readily explained at the genomic level by an underlying point-mutation or deletion. Improved PCR protocols avoiding allelic drop-out of the mutant alleles uncovered insertions of fourteen Alu elements, three L1 elements, and one poly(T stretch to cause these splicing defects. Taken together, the 18 pathogenic L1 endonuclease-mediated de novo insertions represent the largest number of this type of mutations characterized in a single human gene. Our findings show that retrotransposon insertions account for as many as -0.4% of all NF1 mutations. Since altered splicing was the main effect of the inserted elements, the current finding was facilitated by the use of RNA-based mutation analysis protocols, resulting in improved detection compared to gDNA-based approaches. Six different insertions clustered in a relatively small 1.5-kb region (NF1 exons 21(16-23(18 within the 280-kb NF1 gene. Furthermore, three different specific integration sites, one of them located in this cluster region, were each used twice, i.e. NM_000267.3(NF1:c.1642-1_1642 in intron 14(10c, NM_000267.3(NF1:c.2835_2836 in exon 21(16, and NM_000267.3(NF1:c.4319_4320 in exon 33(25. Identification of three loci that each served twice as integration site for independent retrotransposition events as well as 1.5-kb cluster region harboring six independent insertions supports the notion of non-random insertion of retrotransposons in the human genome. Currently, little is known about which features make sites

  20. Lateral flow assays.

    Science.gov (United States)

    Koczula, Katarzyna M; Gallotta, Andrea

    2016-06-30

    Lateral flow assays (LFAs) are the technology behind low-cost, simple, rapid and portable detection devices popular in biomedicine, agriculture, food and environmental sciences. This review presents an overview of the principle of the method and the critical components of the assay, focusing on lateral flow immunoassays. This type of assay has recently attracted considerable interest because of its potential to provide instantaneous diagnosis directly to patients. The range and interpretation of results and parameters used for evaluation of the assay will also be discussed. The main advantages and disadvantages of LFAs will be summarized and relevant future improvements to testing devices and strategies will be proposed. Finally, the major recent advances and future diagnostic applications in the LFA field will be explored. © 2016 The Author(s). Published by Portland Press Limited on behalf of the Biochemical Society.

  1. Lateral flow assays

    Science.gov (United States)

    Koczula, Katarzyna M.

    2016-01-01

    Lateral flow assays (LFAs) are the technology behind low-cost, simple, rapid and portable detection devices popular in biomedicine, agriculture, food and environmental sciences. This review presents an overview of the principle of the method and the critical components of the assay, focusing on lateral flow immunoassays. This type of assay has recently attracted considerable interest because of its potential to provide instantaneous diagnosis directly to patients. The range and interpretation of results and parameters used for evaluation of the assay will also be discussed. The main advantages and disadvantages of LFAs will be summarized and relevant future improvements to testing devices and strategies will be proposed. Finally, the major recent advances and future diagnostic applications in the LFA field will be explored. PMID:27365041

  2. Tube-Forming Assays.

    Science.gov (United States)

    Brown, Ryan M; Meah, Christopher J; Heath, Victoria L; Styles, Iain B; Bicknell, Roy

    2016-01-01

    Angiogenesis involves the generation of new blood vessels from the existing vasculature and is dependent on many growth factors and signaling events. In vivo angiogenesis is dynamic and complex, meaning assays are commonly utilized to explore specific targets for research into this area. Tube-forming assays offer an excellent overview of the molecular processes in angiogenesis. The Matrigel tube forming assay is a simple-to-implement but powerful tool for identifying biomolecules involved in angiogenesis. A detailed experimental protocol on the implementation of the assay is described in conjunction with an in-depth review of methods that can be applied to the analysis of the tube formation. In addition, an ImageJ plug-in is presented which allows automatic quantification of tube images reducing analysis times while removing user bias and subjectivity.

  3. Through-glass copper via using the glass reflow and seedless electroplating processes for wafer-level RF MEMS packaging

    Science.gov (United States)

    Lee, Ju-Yong; Lee, Sung-Woo; Lee, Seung-Ki; Park, Jae-Hyoung

    2013-08-01

    We present a novel method for the fabrication of void-free copper-filled through-glass-vias (TGVs), and their application to the wafer-level radio frequency microelectromechanical systems (RF MEMS) packaging scheme. By using the glass reflow process with a patterned silicon mold, a vertical TGV with smooth sidewall and fine pitch could be achieved. Bottom-up void-free filling of the TGV is successfully demonstrated through the seedless copper electroplating process. In addition, the proposed process allows wafer-level packaging with glass cap encapsulation using the anodic bonding process, since the reflowed glass interposer is only formed in the device area surrounded with silicon substrate. A simple coplanar waveguide (CPW) line was employed as the packaged device to evaluate the electrical characteristics and thermo-mechanical reliability of the proposed packaging structure. The fabricated packaging structure showed a low insertion loss of 0.116 dB and a high return loss of 35.537 dB at 20 GHz, which were measured through the whole electrical path, including the CPW line, TGVs and contact pads. An insertion loss lower than 0.1 dB and a return loss higher than 30 dB could be achieved at frequencies of up to 15 GHz, and the resistance of the single copper via was measured to be 36 mΩ. Furthermore, the thermo-mechanical reliability of the proposed packaging structure was also verified through thermal shock and pressure cooker test.

  4. The impact of packaging on product competition

    Directory of Open Access Journals (Sweden)

    Maryam Masoumi

    2012-09-01

    Full Text Available The primary objective of this paper is to detect important factors, which are influencing competitive advantage. The proposed model of this paper uses sampling technique to measure characteristics of society. There are eight independent variables for the proposed study of this paper including packaging endurance, easy distribution, customer promotion through packaging, packaging structure, packaging as silent advertiser, diversity of packaging, clean and healthy packaging and innovation in packaging. The proposed study uses structural equation modeling to either accept or reject all hypotheses associated with the proposed study of this paper. The population of this study includes all managers and experts who are involved in packaging products. We used simple sampling technique and chooses 300 from a population of 450 people who are considered as the population of this survey. Cronbach alpha was determined as 0.732, which is above the minimum acceptable level. The results confirm that all mentioned factors influence competitiveness, effectively.

  5. Integrated Approach to Industrial Packaging Design

    Science.gov (United States)

    Vorobeva, O.

    2017-11-01

    The article reviews studies in the field of industrial packaging design. The major factors which influence technological, ergonomic, economic and ecological features of packaging are established. The main modern trends in packaging design are defined, the principles of marketing communications and their influence on consumers’ consciousness are indicated, and the function of packaging as a transmitter of brand values is specified. Peculiarities of packaging technology and printing techniques in modern printing industry are considered. The role of designers in the stage-by-stage development of the construction, form and graphic design concept of packaging is defined. The examples of authentic packaging are given and the mention of the tetrahedron packaging history is made. At the end of the article, conclusions on the key research aspects are made.

  6. Automated packaging employing real-time vision

    Science.gov (United States)

    Chang, Wen-Chung; Wu, Chia-Hung

    2016-07-01

    Existing packaging systems rely on human operation to position a box in the packaging device perform do the packaging task. Current facilities are not capable of handling boxes with different sizes in a flexible way. In order to improve the above-mentioned problems, an eye-to-hand visual servo automated packaging approach is proposed in this paper. The system employs two cameras to observe the box and the gripper mounted on the robotic manipulator to precisely control the manipulator to complete the packaging task. The system first employs two-camera vision to determine the box pose. With appropriate task encoding, a closed-loop visual servoing controller is designed to drive a manipulator to accomplish packaging tasks. The proposed approach can be used to complete automated packaging tasks in the case of uncertain location and size of the box. The system has been successfully validated by experimenting with an industrial robotic manipulator for postal box packaging.

  7. Packaging glass with hierarchically nanostructured surface

    KAUST Repository

    He, Jr-Hau

    2017-08-03

    An optical device includes an active region and packaging glass located on top of the active region. A top surface of the packaging glass includes hierarchical nanostructures comprised of honeycombed nanowalls (HNWs) and nanorod (NR) structures extending from the HNWs.

  8. GRIP LIGHTNING INSTRUMENT PACKAGE (LIP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Lightning Instrument Package (LIP) dataset was collected by the Lightning Instrument Package (LIP), which consists of 6 rotating vane type electric field...

  9. Multimedia package for LRFD concrete bridge design.

    Science.gov (United States)

    2009-02-01

    This Project developed a Load and Resistance Factor Design (LRFD) multimedia package to provide a practical introduction and an in-depth understanding of the technological advances in the design of concrete bridges. This package can be used to train ...

  10. 7 CFR 33.6 - Package.

    Science.gov (United States)

    2010-01-01

    ... the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... ISSUED UNDER AUTHORITY OF THE EXPORT APPLE ACT Definitions § 33.6 Package. Package means any container of apples. ...

  11. Development in the Active Packaging of Foods

    African Journals Online (AJOL)

    Active packaging is one of the innovative food packaging concepts that has been introduced as a ... dioxide, flavours/odours and those which release carbon dioxide, .... potential risk could be accidental .... moulds and aerobic bacteria.

  12. Sensory impacts of food-packaging interactions.

    Science.gov (United States)

    Duncan, Susan E; Webster, Janet B

    2009-01-01

    Sensory changes in food products result from intentional or unintentional interactions with packaging materials and from failure of materials to protect product integrity or quality. Resolving sensory issues related to plastic food packaging involves knowledge provided by sensory scientists, materials scientists, packaging manufacturers, food processors, and consumers. Effective communication among scientists and engineers from different disciplines and industries can help scientists understand package-product interactions. Very limited published literature describes sensory perceptions associated with food-package interactions. This article discusses sensory impacts, with emphasis on oxidation reactions, associated with the interaction of food and materials, including taints, scalping, changes in food quality as a function of packaging, and examples of material innovations for smart packaging that can improve sensory quality of foods and beverages. Sensory evaluation is an important tool for improved package selection and development of new materials.

  13. Experimental testing of exchangeable cutting inserts cutting ability

    OpenAIRE

    Čep, Robert; Janásek, Adam; Čepová, Lenka; Petrů, Jana; Hlavatý, Ivo; Car, Zlatan; Hatala, Michal

    2013-01-01

    The article deals with experimental testing of the cutting ability of exchangeable cutting inserts. Eleven types of exchangeable cutting inserts from five different manufacturers were tested. The tested cutting inserts were of the same shape and were different especially in material and coating types. The main aim was both to select a suitable test for determination of the cutting ability of exchangeable cutting inserts and to design such testing procedure that could make it possible...

  14. Modelling the comet assay.

    Science.gov (United States)

    McArt, Darragh G; McKerr, George; Howard, C Vyvyan; Saetzler, Kurt; Wasson, Gillian R

    2009-08-01

    The single-cell gel electrophoresis technique or comet assay is widely regarded as a quick and reliable method of analysing DNA damage in individual cells. It has a proven track record from the fields of biomonitoring to nutritional studies. The assay operates by subjecting cells that are fixed in agarose to high salt and detergent lysis, thus removing all the cellular content except the DNA. By relaxing the DNA in an alkaline buffer, strands containing breaks are released from supercoiling. Upon electrophoresis, these strands are pulled out into the agarose, forming a tail which, when stained with a fluorescent dye, can be analysed by fluorescence microscopy. The intensity of this tail reflects the amount of DNA damage sustained. Despite being such an established and widely used assay, there are still many aspects of the comet assay which are not fully understood. The present review looks at how the comet assay is being used, and highlights some of its limitations. The protocol itself varies among laboratories, so results from similar studies may vary. Given such discrepancies, it would be attractive to break the assay into components to generate a mathematical model to investigate specific parameters.

  15. First installation of DT and RPC packages into the CMS iron yoke

    CERN Multimedia

    Jesus Puerta-Pelayo

    2004-01-01

    These pictures illustrate the installation process of muon barrel packages (DT + RPC) into the pockets of the CMS iron yoke at SX5. The chambers are first transported in groups of four from the ISR area (where they are certified and coupled together) to the construction hall in Cessy (neighbouring France), called Point 5 (or SX5). Once there, they pass through a fast high voltage and electronic certification test, before being slid into the insertion cradle. This cradle is attached to the yoke and aligned to the chamber rails, allowing an easy insertion. A rate of 3 chambers per day can be achieved. This set of pictures was taken during the first final insertion round at Point 5, where most chambers for the lower part of YB+2 were installed.

  16. Photograph of moon after transearth insertion

    Science.gov (United States)

    1969-01-01

    This photograph of the moon was taken after transearth insertion when the Apollo 10 spacecraft was high above the lunar equator near 27 degrees east longitude. North is about 20 degrees left of the top of the photograph. Apollo Landing Site 3 is on the lighted side of the terminator in a dark area just north of the equator. Apollo Landing Site 2 is near the lower left margin of the Sea of Tranquility (Mare Tranquillitatis), which is the large, dark area near the center of the photograph.

  17. An adaptive transposable element insertion in the regulatory region of the EO gene in the domesticated silkworm, Bombyx mori.

    Science.gov (United States)

    Sun, Wei; Shen, Yi-Hong; Han, Min-Jin; Cao, Yun-Feng; Zhang, Ze

    2014-12-01

    Although there are many studies to show a key role of transposable elements (TEs) in adaptive evolution of higher organisms, little is known about the molecular mechanisms. In this study, we found that a partial TE (Taguchi) inserted in the cis-regulatory region of the silkworm ecdysone oxidase (EO) gene, which encodes a crucial enzyme to reduce the titer of molting hormone (20-hydroxyecdysone, 20E). The TE insertion occurred during domestication of silkworm and the frequency of the TE insertion in the domesticated silkworm (Bombyx mori) is high, 54.24%. The linkage disequilibrium in the TE inserted strains of the domesticated silkworm was elevated. Molecular population genetics analyses suggest that this TE insertion is adaptive for the domesticated silkworm. Luminescent reporter assay shows that the TE inserted in the cis-regulatory region of the EO gene functions as a 20E-induced enhancer of the gene expression. Further, phenotypic bioassay indicates that the silkworm with the TE insertion exhibited more stable developmental phenotype than the silkworm without the TE insertion when suffering from food shortage. Thus, the inserted TE in the cis-regulatory region of the EO gene increased developmental uniformity of silkworm individuals through regulating 20E metabolism, partially explaining transformation of a domestication developmental trait in the domesticated silkworm. Our results emphasize the exceptional role of gene expression regulation in developmental transition of domesticated animals. © The Author 2014. Published by Oxford University Press on behalf of the Society for Molecular Biology and Evolution. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Introducing Experience Goals into Packaging Design

    OpenAIRE

    Joutsela, Markus; Roto, Virpi; Lloyd, Peter; Bohemia, Erik

    2016-01-01

    Consumer experiences are an increasingly important driving force for commerce, affecting also packaging design. Yet, experience design for packages is rarely studied. Specifically, there is a gap in research regarding the integration of experiential goals, Xgoals, into the packaging design process. Open questions include how to describe Xgoals in design briefs when package design is outsourced, how to deal with changes during the design process, and how to evaluate whether the delivered desig...

  19. Comparison of environmental sustainability of pharmaceutical packaging

    OpenAIRE

    Geo Raju; Prabir Sarkar; Ekta Singla; Harpreet Singh; Rachit Kumar Sharma

    2016-01-01

    Pharmaceutical companies are increasingly imparting a lot of importance on becoming more sustainable by developing medicines that are having same medicinal value but with reduced environmental impact. Type of packaging of tablets affects the emission generated during packaging of medicines. Selection of an appropriate packaging of medicine also influences the emission added to the environment. This paper aims at the comparison of environmental impacts of two different types of packaging of ta...

  20. Can Peripheral Central Venous Lines be inserted safely and ...

    African Journals Online (AJOL)

    Background: Primary care settings often lack facilities for radiological evaluation of the position of supra-and infra-clavicularly inserted central venous catheters. If peripherally inserted central venous lines could reliably be successfully inserted this would make the need for immediate confirmatory radiological studies less ...

  1. 21 CFR 886.5420 - Contact lens inserter/remover.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Contact lens inserter/remover. 886.5420 Section 886.5420 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5420 Contact lens inserter/remover. (a) Identification. A contact lens inserter...

  2. The Development of Chronic Insertable Oxygen Electrodes.

    Science.gov (United States)

    1979-07-01

    in defining the aging process that occurs at the working electrode of a blood oxygen electro - chemical sensor. A specific pre-treatment protocol was...transducer) or acCO vol tage input ( EKG , EEG). This telemetry package has been fabricated, bench tested and field tested (see below). Two sets of in vivo...Transport to TiP.sue Ill. Ed. by l.A. Silver, Plenum Publ. Curp., New York. 3. Delahay, P. (19Si4) New lnstiumental Methods in Electro - cheinistry

  3. Developments in the active packaging of foods

    NARCIS (Netherlands)

    Vermeiren, L.; Devlieghere, F.; Beest, M. van; Kruijf, N. de; Debevere, J.

    1999-01-01

    Active packaging is one of the innovative food packaging concepts that has been introduced as a response to the continuous changes in current consumer demands and market trends. Major active packaging techniques are concerned with substances that absorb oxygen, ethylene, moisture, carbon dioxide,

  4. 9 CFR 317.24 - Packaging materials.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Packaging materials. 317.24 Section... INSPECTION AND CERTIFICATION LABELING, MARKING DEVICES, AND CONTAINERS General § 317.24 Packaging materials... packaging materials must be safe for their intended use within the meaning of section 409 of the Federal...

  5. Packaging of Sin Goods - Commitment or Exploitation?

    DEFF Research Database (Denmark)

    Nafziger, Julia

    to such self-control problems, and possibly exploit them, by offering different package sizes. In a competitive market, either one or three (small, medium and large) packages are offered. In contrast to common intuition, the large, and not the small package is a commitment device. The latter serves to exploit...

  6. 27 CFR 30.43 - Packaged spirits.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Packaged spirits. 30.43... Packaged spirits. When the quantity of spirits (including denatured spirits when gauged by weight) in... by weighing each package on an accurate weighing beam or platform scale having a beam or dial showing...

  7. Consumer perception: attributes considered important in packaging

    Directory of Open Access Journals (Sweden)

    Nara Medianeira Stefano

    2012-08-01

    Full Text Available Packaging has been considered the main vehicle for sales, brand building and product identity, since it is the first contact with the product that the consumer has, it is fundamental when choosing and buying a product. In this sense, the packaging is a silent salesperson, because it is up to the package to attract attention, create interest and desire, show the quality of the product and close the sale within seconds. Packaging has contributed to corporate communication with consumers; it provides product protection, storage and convenience, as products move through the value chain. Thinking about it, the product cannot be planned separately from its packaging, and it should not be defined based only on engineering, marketing, communications or economics. The packaging concept has expanded and gained product status; packaging is able to communicate the same language of convenience wherever it goes. Today, packaging industries are taking advantage of this opportunity to differentiate their products through packaging, finding that it is not enough for the package to be beautiful, unbreakable, or preserve the flavor and freshness of foods. Within this context, the objective of this research is to analyze, from the point of view of consumers, the most important product packaging attributes at the time of purchase. For this purpose, the data obtained in this study was run through the Statistica 8.0 and SPSS 16 (Statistical Package Social Sciences software’s.

  8. ICT and the paperboard and packaging industry

    Science.gov (United States)

    Peter Ince; Sanna Kallioranta; Richard Vlosky

    2005-01-01

    The purpose of this chapter is to describe the reasons for the development of ICT and e-business systems in the paper and paperboard packaging industry and to discuss future scenarios that may serve to guide forest- sector research in this topical area. The paper and paperboard packaging industry encompasses producers of primary paper and paperboard packaging materials...

  9. 7 CFR 65.130 - Consumer package.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Consumer package. 65.130 Section 65.130 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards..., PEANUTS, AND GINSENG General Provisions Definitions § 65.130 Consumer package. Consumer package means any...

  10. 7 CFR 993.22 - Consumer package.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Consumer package. 993.22 Section 993.22 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Order Regulating Handling Definitions § 993.22 Consumer package. Consumer package means: (a) Any...

  11. Packaging of high power semiconductor lasers

    CERN Document Server

    Liu, Xingsheng; Xiong, Lingling; Liu, Hui

    2014-01-01

    This book introduces high power semiconductor laser packaging design. The characteristics and challenges of the design and various packaging, processing, and testing techniques are detailed by the authors. New technologies, in particular thermal technologies, current applications, and trends in high power semiconductor laser packaging are described at length and assessed.

  12. Magnetic Package data quality overview

    DEFF Research Database (Denmark)

    Qamili, Enkelejda; Ottavianelli, Giuseppe; Olsen, Nils

    The ESA Swarm satellites, launched in November 2013, carry on-board instuments devoted to measure extremely accurate data necessary to improve our understanding of Earth’s magnetic field. The Swarm instrument package is made by two magnetometers (one vector and one scalar), one Electric field Ins...... Instrument (EFI), one Accelerometer and one GPS reciever. This presentation aims at providing an extensive overview of the magnetic instrument status, magnetic data availability and quality.......The ESA Swarm satellites, launched in November 2013, carry on-board instuments devoted to measure extremely accurate data necessary to improve our understanding of Earth’s magnetic field. The Swarm instrument package is made by two magnetometers (one vector and one scalar), one Electric field...

  13. Construction of Small-Insert and Large-Insert Metagenomic Libraries.

    Science.gov (United States)

    Simon, Carola; Daniel, Rolf

    2017-01-01

    The vast majority of the Earth's biological diversity is hidden in uncultured and yet uncharacterized microbial genomes. The construction of metagenomic libraries is a cultivation-independent molecular approach to assess this unexplored genetic reservoir. High numbers of novel biocatalysts have been identified by function-based or sequence-based screening of metagenomic libraries derived from various environments. Here, we describe detailed protocols for the construction of metagenomic small-insert and large-insert libraries in plasmids and fosmids, respectively, from environmental DNA.

  14. Transportation and packaging resource guide

    Energy Technology Data Exchange (ETDEWEB)

    Arendt, J.W.; Gove, R.M.; Welch, M.J.

    1994-12-01

    The purpose of this resource guide is to provide a convenient reference document of information that may be useful to the U.S. Department of Energy (DOE) and DOE contractor personnel involved in packaging and transportation activities. An attempt has been made to present the terminology of DOE community usage as it currently exists. DOE`s mission is changing with emphasis on environmental cleanup. The terminology or nomenclature that has resulted from this expanded mission is included for the packaging and transportation user for reference purposes. Older terms still in use during the transition have been maintained. The Packaging and Transportation Resource Guide consists of four sections: Sect. 1, Introduction; Sect. 2, Abbreviations and Acronyms; Sect. 3, Definitions; and Sect. 4, References for packaging and transportation of hazardous materials and related activities, and Appendices A and B. Information has been collected from DOE Orders and DOE documents; U.S Department of Transportation (DOT), U.S. Environmental Protection Agency (EPA), and U.S. Nuclear Regulatory Commission (NRC) regulations; and International Atomic Energy Agency (IAEA) standards and other international documents. The definitions included in this guide may not always be a regulatory definition but are the more common DOE usage. In addition, the definitions vary among regulatory agencies. It is, therefore, suggested that if a definition is to be used in a regulatory or a legal compliance issue, the definition should be verified with the appropriate regulation. To assist in locating definitions in the regulations, a listing of all definition sections in the regulations are included in Appendix B. In many instances, the appropriate regulatory reference is indicated in the right-hand margin.

  15. Small Cold Temperature Instrument Packages

    Science.gov (United States)

    Clark, P. E.; Millar, P. S.; Yeh, P. S.; Feng, S.; Brigham, D.; Beaman, B.

    We are developing a small cold temperature instrument package concept that integrates a cold temperature power system with ultra low temperature ultra low power electronics components and power supplies now under development into a 'cold temperature surface operational' version of a planetary surface instrument package. We are already in the process of developing a lower power lower temperature version for an instrument of mutual interest to SMD and ESMD to support the search for volatiles (the mass spectrometer VAPoR, Volatile Analysis by Pyrolysis of Regolith) both as a stand alone instrument and as part of an environmental monitoring package. We build on our previous work to develop strategies for incorporating Ultra Low Temperature/Ultra Low Power (ULT/ULP) electronics, lower voltage power supplies, as well as innovative thermal design concepts for instrument packages. Cryotesting has indicated that our small Si RHBD CMOS chips can deliver >80% of room temperature performance at 40K (nominal minimum lunar surface temperature). We leverage collaborations, past and current, with the JPL battery development program to increase power system efficiency in extreme environments. We harness advances in MOSFET technology that provide lower voltage thresholds for power switching circuits incorporated into our low voltage power supply concept. Conventional power conversion has a lower efficiency. Our low power circuit concept based on 'synchronous rectification' could produce stable voltages as low as 0.6 V with 85% efficiency. Our distributed micro-battery-based power supply concept incorporates cold temperature power supplies operating with a 4 V or 8 V battery. This work will allow us to provide guidelines for applying the low temperature, low power system approaches generically to the widest range of surface instruments.

  16. Lithium Insertion Chemistry of Some Iron Vanadates

    Energy Technology Data Exchange (ETDEWEB)

    Patoux, Sebastien; Richardson, Thomas J.

    2007-02-02

    Lithium insertion into various iron vanadates has been investigated. Fe{sub 2}V{sub 4}O{sub 13} and Fe{sub 4}(V{sub 2}O{sub 7}){sub 3} {center_dot} 3H{sub 2}O have discharge capacities approaching 200 mAh/g above 2.0 V vs. Li{sup +}/Li. Although the potential profiles change significantly between the first and subsequent discharges, capacity retention is unexpectedly good. Other phases, structurally related to FeVO{sub 4}, containing copper and/or sodium ions were also studied. One of these, {beta}-Cu{sub 3}Fe{sub 4}(VO{sub 4}){sub 6}, reversibly consumes almost 10 moles of electrons per formula unit (ca. 240 mAh g{sup -1}) between 3.6 and 2.0 V vs. Li{sup +}/Li, in a non-classical insertion process. It is proposed that both copper and vanadium are electrochemically active, whereas iron(III) reacts to form LiFe{sup III}O{sub 2}. The capacity of the Cu{sub 3}Fe{sub 4}(VO{sub 4}){sub 6}/Li system is nearly independent of cycling rate, stabilizing after a few cycles at 120-140 mAh g{sup -1}. Iron vanadates exhibit better capacities than their phosphate analogues, whereas the latter display more constant discharge potentials.

  17. Polymeric Biodegradable Stent Insertion in the Esophagus

    Directory of Open Access Journals (Sweden)

    Kai Yang

    2016-04-01

    Full Text Available Esophageal stent insertion has been used as a well-accepted and effective alternative to manage and improve the quality of life for patients diagnosed with esophageal diseases and disorders. Current stents are either permanent or temporary and are fabricated from either metal or plastic. The partially covered self-expanding metal stent (SEMS has a firm anchoring effect and prevent stent migration, however, the hyperplastic tissue reaction cause stent restenosis and make it difficult to remove. A fully covered SEMS and self-expanding plastic stent (SEPS reduced reactive hyperplasia but has a high migration rate. The main advantage that polymeric biodegradable stents (BDSs have over metal or plastic stents is that removal is not require and reduce the need for repeated stent insertion. But the slightly lower radial force of BDS may be its main shortcoming and a post-implant problem. Thus, strengthening support of BDS is a content of the research in the future. BDSs are often temporarily effective in esophageal stricture to relieve dysphagia. In the future, it can be expect that biodegradable drug-eluting stents (DES will be available to treat benign esophageal stricture, perforations or leaks with additional use as palliative modalities for treating malignant esophageal stricture, as the bridge to surgery or to maintain luminal patency during neoadjuvant chemoradiation.

  18. Cigarette Mouth Insertion Depths Among Chinese Smokers

    Directory of Open Access Journals (Sweden)

    Hu Q

    2014-12-01

    Full Text Available Vent blocking - where filter ventilation holes are intentionally or unintentionally, partly or completely covered by smokers’ lips during smoking - is an aspect of smoking behavior which can alter mainstream smoke yields. This study was designed to determine if, and to what extent ventilation holes were blocked by smokers’ lips in two cohorts of Chinese smokers. In this study, two groups of samples were collected. One group (1742 butts was collected randomly from public places in six chosen cities. Another (1037 butts was obtained by collecting the butts from identified smokers in Kunming. In this paper, the mouth insertion depth among Chinese smokers was studied for the first time by a staining method employing ninhydrin in ethanol. The results indicate that Chinese smokers exhibit a mouth insertion depth ranging from 1 to 17 mm with an average value of 7.5 AA± 2 mm. In this study, 95% of the ventilated filters examined showed that the vent zone was neither completely nor partially covered by smokers’ lips.

  19. Waste Package Design Methodology Report

    Energy Technology Data Exchange (ETDEWEB)

    D.A. Brownson

    2001-09-28

    The objective of this report is to describe the analytical methods and processes used by the Waste Package Design Section to establish the integrity of the various waste package designs, the emplacement pallet, and the drip shield. The scope of this report shall be the methodology used in criticality, risk-informed, shielding, source term, structural, and thermal analyses. The basic features and appropriateness of the methods are illustrated, and the processes are defined whereby input values and assumptions flow through the application of those methods to obtain designs that ensure defense-in-depth as well as satisfy requirements on system performance. Such requirements include those imposed by federal regulation, from both the U.S. Department of Energy (DOE) and U.S. Nuclear Regulatory Commission (NRC), and those imposed by the Yucca Mountain Project to meet repository performance goals. The report is to be used, in part, to describe the waste package design methods and techniques to be used for producing input to the License Application Report.

  20. Hazardous Material Packaging and Transportation

    Energy Technology Data Exchange (ETDEWEB)

    Hypes, Philip A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-02-04

    This is a student training course. Some course objectives are to: recognize and use standard international and US customary units to describe activities and exposure rates associated with radioactive material; determine whether a quantity of a single radionuclide meets the definition of a class 7 (radioactive) material; determine, for a given single radionuclide, the shipping quantity activity limits per 49 Code of Federal Regulations (CFR) 173.435; determine the appropriate radioactive material hazard class proper shipping name for a given material; determine when a single radionuclide meets the DOT definition of a hazardous substance; determine the appropriate packaging required for a given radioactive material; identify the markings to be placed on a package of radioactive material; determine the label(s) to apply to a given radioactive material package; identify the entry requirements for radioactive material labels; determine the proper placement for radioactive material label(s); identify the shipping paper entry requirements for radioactive material; select the appropriate placards for a given radioactive material shipment or vehicle load; and identify allowable transport limits and unacceptable transport conditions for radioactive material.

  1. Active packaging with antifungal activities.

    Science.gov (United States)

    Nguyen Van Long, N; Joly, Catherine; Dantigny, Philippe

    2016-03-02

    There have been many reviews concerned with antimicrobial food packaging, and with the use of antifungal compounds, but none provided an exhaustive picture of the applications of active packaging to control fungal spoilage. Very recently, many studies have been done in these fields, therefore it is timely to review this topic. This article examines the effects of essential oils, preservatives, natural products, chemical fungicides, nanoparticles coated to different films, and chitosan in vitro on the growth of moulds, but also in vivo on the mould free shelf-life of bread, cheese, and fresh fruits and vegetables. A short section is also dedicated to yeasts. All the applications are described from a microbiological point of view, and these were sorted depending on the name of the species. Methods and results obtained are discussed. Essential oils and preservatives were ranked by increased efficacy on mould growth. For all the tested molecules, Penicillium species were shown more sensitive than Aspergillus species. However, comparison between the results was difficult because it appeared that the efficiency of active packaging depended greatly on the environmental factors of food such as water activity, pH, temperature, NaCl concentration, the nature, the size, and the mode of application of the films, in addition to the fact that the amount of released antifungal compounds was not constant with time. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Package security recorder of vibration

    Science.gov (United States)

    Wang, Xiao-na; Hu, Jin-liang; Song, Shi-de

    2013-08-01

    This paper introduces a new kind of electronic product — Package Security Recorder of Vibration. It utilizes STC89C54RD+ LQFP-44 MCU as its main controller. At the same time, it also utilizes Freescale MMA845A 3-Axis 8-bit/12-bit Digital Accelerometer and Maxim DS1302 Trickle Charge Timekeeping Chip. It utilizes the MCU to read the value of the accelerometer and the value of the timekeeping chip, and records the data into the inner E2PROM of MCU. The whole device achieves measuring, reading and recording the time of the vibration and the intensity of the vibration. When we need the data, we can read them out. The data can be used in analyzing the condition of the cargo when it transported. The device can be applied to monitor the security of package. It solves the problem of responsibility affirming, when the valuable cargo are damaged while it transported. It offers powerful safeguard for the package. It's very value for application.

  3. Insertion of coherence requests for debugging a multiprocessor

    Science.gov (United States)

    Blumrich, Matthias A.; Salapura, Valentina

    2010-02-23

    A method and system are disclosed to insert coherence events in a multiprocessor computer system, and to present those coherence events to the processors of the multiprocessor computer system for analysis and debugging purposes. The coherence events are inserted in the computer system by adding one or more special insert registers. By writing into the insert registers, coherence events are inserted in the multiprocessor system as if they were generated by the normal coherence protocol. Once these coherence events are processed, the processing of coherence events can continue in the normal operation mode.

  4. Examination of SR101 shipping packages

    Energy Technology Data Exchange (ETDEWEB)

    Daugherty, W. L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-03-01

    Four SR101 shipping packages were removed from service and provided for disassembly and examination of the internal fiberboard assemblies. These packages were 20 years old, and had experienced varying levels of degradation. Two of the packages were successfully disassembled and fiberboard samples were removed from these packages and tested. Mechanical and thermal property values are generally comparable to or higher than baseline values measured on fiberboard from 9975 packages, which differs primarily in the specified density range. While baseline data for the SR101 material is not available, this comparison with 9975 material suggests that the material properties of the SR101 fiberboard have not significantly degraded.

  5. The Model 9977 Radioactive Material Packaging Primer

    Energy Technology Data Exchange (ETDEWEB)

    Abramczyk, G. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-10-09

    The Model 9977 Packaging is a single containment drum style radioactive material (RAM) shipping container designed, tested and analyzed to meet the performance requirements of Title 10 the Code of Federal Regulations Part 71. A radioactive material shipping package, in combination with its contents, must perform three functions (please note that the performance criteria specified in the Code of Federal Regulations have alternate limits for normal operations and after accident conditions): Containment, the package must “contain” the radioactive material within it; Shielding, the packaging must limit its users and the public to radiation doses within specified limits; and Subcriticality, the package must maintain its radioactive material as subcritical

  6. Challenges in the Packaging of MEMS

    Energy Technology Data Exchange (ETDEWEB)

    Malshe, A.P.; Singh, S.B.; Eaton, W.P.; O' Neal, C.; Brown, W.D.; Miller, W.M.

    1999-03-26

    The packaging of Micro-Electro-Mechanical Systems (MEMS) is a field of great importance to anyone using or manufacturing sensors, consumer products, or military applications. Currently much work has been done in the design and fabrication of MEMS devices but insufficient research and few publications have been completed on the packaging of these devices. This is despite the fact that packaging is a very large percentage of the total cost of MEMS devices. The main difference between IC packaging and MEMS packaging is that MEMS packaging is almost always application specific and greatly affected by its environment and packaging techniques such as die handling, die attach processes, and lid sealing. Many of these aspects are directly related to the materials used in the packaging processes. MEMS devices that are functional in wafer form can be rendered inoperable after packaging. MEMS dies must be handled only from the chip sides so features on the top surface are not damaged. This eliminates most current die pick-and-place fixtures. Die attach materials are key to MEMS packaging. Using hard die attach solders can create high stresses in the MEMS devices, which can affect their operation greatly. Low-stress epoxies can be high-outgassing, which can also affect device performance. Also, a low modulus die attach can allow the die to move during ultrasonic wirebonding resulting to low wirebond strength. Another source of residual stress is the lid sealing process. Most MEMS based sensors and devices require a hermetically sealed package. This can be done by parallel seam welding the package lid, but at the cost of further induced stress on the die. Another issue of MEMS packaging is the media compatibility of the packaged device. MEMS unlike ICS often interface with their environment, which could be high pressure or corrosive. The main conclusion we can draw about MEMS packaging is that the package affects the performance and reliability of the MEMS devices. There is a

  7. Lunar Dust Analysis Package - LDAP

    Science.gov (United States)

    Chalkley, S. A.; Richter, L.; Goepel, M.; Sovago, M.; Pike, W. T.; Yang, S.; Rodenburg, J.; Claus, D.

    2012-09-01

    The Lunar Dust Analysis package (L-DAP) is a suite of payloads which have been designed to operate in synergy with each other at the Lunar Surface. The benefits of combining these payloads in a single package allow very precise measurements of a particular regolith sample. At the same time the integration allows mass savings since common resources are shared and this also means that interfaces with the Lander are simplified significantly leading to benefits of integration and development of the overall mission. Lunar Dust represents a real hazard for lunar exploration due to its invasive, fine microscopic structure and toxic properties. However it is also valuable resource which could be exploited for future exploration if the characteristics and chemical composition is well known. Scientifically, the regolith provides an insight into the moon formation process and there are areas on the Moon which have never been ex-plored before. For example the Lunar South Pole Aitken Basin is the oldest and largest on the moon, providing excavated deep crust which has not been found on the previous lunar landing missions. The SEA-led team has been designing a compact package, known as LDAP, which will provide key data on the lunar dust properties. The intention is for this package to be part of the payload suite deployed on the ESA Lunar Lander Mission in 2018. The LDAP has a centralised power and data electronics, including front end electronics for the detectors as well as sample handling subsystem for the following set of internal instruments : • Optical Microscope - with a 1μm resolution to provide context of the regolith samples • Raman and LIBS spectrographic instrumentation providing quantification of mineral and elemental composition information of the soil at close to grain scale. This includes the capability to detect (and measure abundance of) crystalline and adsorbed volatile phases, from their Raman signature. The LIBS equipment will also allow chemical

  8. Rover waste assay system

    Energy Technology Data Exchange (ETDEWEB)

    Akers, D.W.; Stoots, C.M.; Kraft, N.C.; Marts, D.J. [Idaho National Engineering Lab., Idaho Falls, ID (United States)

    1997-11-01

    The Rover Waste Assay System (RWAS) is a nondestructive assay system designed for the rapid assay of highly-enriched {sup 235}U contaminated piping, tank sections, and debris from the Rover nuclear rocket fuel processing facility at the Idaho Chemical Processing Plant. A scanning system translates a NaI(Tl) detector/collimator system over the structural components where both relative and calibrated measurements for {sup 137}Cs are made. Uranium-235 concentrations are in operation and is sufficiently automated that most functions are performed by the computer system. These functions include system calibration, problem identification, collimator control, data analysis, and reporting. Calibration of the system was done through a combination of measurements on calibration standards and benchmarked modeling. A description of the system is presented along with the methods and uncertainties associated with the calibration and analysis of the system for components from the Rover facility. 4 refs., 2 figs., 4 tabs.

  9. The art of packaging: An investigation into the role of color in packaging, marketing, and branding

    OpenAIRE

    Behzad Mohebbi

    2014-01-01

    The purpose of this study is to contribute to the existing research in the field of packaging and marketing and shed more light on the psychology of colors and their effect on packaging and marketing. Nowadays, packaging is proved to be one of the significant factors in the success of promoting product sale. However, there is a perceived gap with respect to the different aspects of packaging, in particular the graphics, design, and color of packaging. The current study provides...

  10. Safety analysis report -- Packages LP-50 tritium package (Packaging of fissile and other radioactive materials)

    Energy Technology Data Exchange (ETDEWEB)

    Gates, A.A.; McCarthy, P.G.; Edl, J.W.; Chalfant, G.G. (comps.); Cadelli, G.

    1975-05-01

    Elemental tritium is shipped at low pressure in a stainless steel container (LP-50) surrounded by an aluminum vessel and Celotex insulation at least 4 in. thick in a steel drum. Each package contains a large quantity (greater than a Type A quantity) of nonfissile material, as defined in AECM 0529. This report provides the details of the safety analysis performed for this type container.

  11. Antimicrobial packaging with natural compunds - a review

    Directory of Open Access Journals (Sweden)

    Renata Dobrucka

    2016-12-01

    Full Text Available Background:  Packaging problems are an integral part of logistics and the implementation of packaging significantly affects the effectiveness of logistics processes, as a factor which increases the safety and the quality of products being transported. Active packaging is an area of technology needed to meet the requirements of the contemporary consumer. Active packaging creates additional opportunities in systems for packing goods, as well as offering a solution in which the packaging, the product and surroundings interact. Furthermore, active packaging allows packaging to interact with food and the environment and play a dynamic role in food preservation. The main role of antimicrobial packaging is to inhibit the growth of microorganisms that reduce the quality of the packaged product. Methods: The application of natural antimicrobial agents appears to be safe for food products. Also, these compounds have potential applications as a natural preservative in the food packaging industry. This study presents some antibacterial agents, namely chitosan, nisin and pectins. Results and conclusion: Natural substances used in active packaging can eliminate the danger of chemical substances migrating to food.

  12. Non-insertional tendinopathy of the subscapularis.

    Science.gov (United States)

    Dierckman, Brian D; Shah, Nirav R; Larose, Connor R; Gerbrandt, Stacey; Getelman, Mark H

    2013-07-01

    (1) Describe a previously unreported finding involving the intra-articular portion of the subscapularis, the Conrad lesion. (2) Describe a novel classification system for the spectrum of non-insertional tendinopathy of the subscapularis. (3) Report the outcomes of surgical treatment of this spectrum of pathology. Outcomes of 34 patients (23 males and 11 females, mean age 60.5 ± 7.5) with non-insertional tendinopathy of the subscapularis treated arthroscopically were retrospectively reviewed. All patients had anterior shoulder pain with no weakness during belly-press testing and no subscapularis footprint involvement on magnetic resonance imaging. All patients were managed with subscapularis tendon debridement and side-to-side repair along with treatment of concomitant pathology. Seven patients had a Type I lesion (so-called Conrad lesion) - a nodule on the leading edge of the subscapularis. Eighteen patients had a Type II lesion - a visible split tear with degeneration in the upper ½ of the intra-articular tendon. Nine patients had a Type III lesion - more extensive splitting in the tendon with advanced tendon degeneration. At a mean follow-up of 24 months, 97% of patients were completely satisfied. Significant improvements were seen in forward elevation (152 ± 12° to 172 ± 5°, P < 0.001) and visual analog scale pain scores (5.9 ± 1.7-0.6 ± 1.0, P < 0.001). Internal rotation strength and external rotation motion at the side were maintained. ASES scores averaged 95.4 ± 7.4, disabilities of arm, shoulder and hand scores averaged 6.19 ± 9.8, Western Ontario Rotator Cuff scores averaged 91.7 ± 9.3 and the average University of California at Los Angeles score was 33.1 ± 2.4. We present a previously unreported finding of the subscapularis, the Conrad lesion, along with a novel classification system for non-insertional tendinopathy of the subscapularis. Arthroscopic treatment of this spectrum of tendinopathy along with concomitant shoulder pathology eliminated

  13. IMS Content Packaging v1.2 public draft specification

    NARCIS (Netherlands)

    Burgos, Daniel; Tattersall, Colin; Vogten, Hubert

    2006-01-01

    The IMS Content Packaging Specification provides the functionality to describe and package learning materials, such as an individual course or a collection of courses, into interoperable, distributable packages. Content Packaging addresses the description, structure, and location of online learning

  14. Package Formats for Preserved Digital Material

    DEFF Research Database (Denmark)

    Zierau, Eld

    2012-01-01

    This paper presents an investigation of the best suitable package formats for long term digital preservation. The choice of a package format for preservation is crucial for future access, thus a thorough analysis of choice is important. The investigation presented here covers setting up requireme......This paper presents an investigation of the best suitable package formats for long term digital preservation. The choice of a package format for preservation is crucial for future access, thus a thorough analysis of choice is important. The investigation presented here covers setting up...... requirements for package formats used for long term preserved digital material, and using these requirements as the basis for analysing a range of package formats. The result of the concrete investigation is that the WARC format is the package format best suited for the listed requirements. Fulfilling......, e.g. if there are specific forensic or direct access to files....

  15. Examination of shipping package 9975-02403

    Energy Technology Data Exchange (ETDEWEB)

    Daugherty, W. L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-03-01

    SRNL examined shipping package 9975-02403 following storage of nuclear material in K-Area Complex (KAC). As a result of field surveillance activities in KAC, this package was identified to contain several non-conforming and other conditions. Further examination of this package in SRNL confirmed significant moisture and mold in the bottom layers of the lower fiberboard assembly, and identified additional corrosion along the seam weld and on the bottom of the drum. It was recently recommended that checking for corrosion along the bottom edge of the drum be implemented for packages that are removed from storage, as well as high wattage packages remaining in storage. The appearance of such corrosion on 9975-02403 further indicates that such corrosion may provide an indication of significant moisture concentration and related degradation within the package. This condition is more likely to develop in packages with higher internal heat loads.

  16. RF and microwave microelectronics packaging II

    CERN Document Server

    Sturdivant, Rick

    2017-01-01

    Reviews RF, microwave, and microelectronics assembly process, quality control, and failure analysis Bridges the gap between low cost commercial and hi-res RF/Microwave packaging technologies Engages in an in-depth discussion of challenges in packaging and assembly of advanced high-power amplifiers This book presents the latest developments in packaging for high-frequency electronics. It is a companion volume to “RF and Microwave Microelectronics Packaging” (2010) and covers the latest developments in thermal management, electrical/RF/thermal-mechanical designs and simulations, packaging and processing methods, and other RF and microwave packaging topics. Chapters provide detailed coverage of phased arrays, T/R modules, 3D transitions, high thermal conductivity materials, carbon nanotubes and graphene advanced materials, and chip size packaging for RF MEMS. It appeals to practicing engineers in the electronic packaging and high-frequency electronics domain, and to academic researchers interested in underst...

  17. Lateral flow strip assay

    Science.gov (United States)

    Miles, Robin R [Danville, CA; Benett, William J [Livermore, CA; Coleman, Matthew A [Oakland, CA; Pearson, Francesca S [Livermore, CA; Nasarabadi, Shanavaz L [Livermore, CA

    2011-03-08

    A lateral flow strip assay apparatus comprising a housing; a lateral flow strip in the housing, the lateral flow strip having a receiving portion; a sample collection unit; and a reagent reservoir. Saliva and/or buccal cells are collected from an individual using the sample collection unit. The sample collection unit is immersed in the reagent reservoir. The tip of the lateral flow strip is immersed in the reservoir and the reagent/sample mixture wicks up into the lateral flow strip to perform the assay.

  18. Impact of Orthodontic Decompensation on Bone Insertion

    Directory of Open Access Journals (Sweden)

    Fabio Pinto Guedes

    2014-01-01

    Full Text Available There has always been concern in determining the relationship between orthodontic tooth movement and the consequent biological costs to the periodontium and tooth root. The possibility of evaluating the tooth and bone morphology by CBCT allows more accurate analysis of qualitative and quantitative aspects of these processes. This paper presents a case report of a 20-year-old male patient with Class III malocclusion and hyperdivergent facial pattern, who was surgically treated. A significant amount of labial movement of mandibular incisors was performed during orthodontic treatment before surgery. CBCT was used for evaluation of buccal and lingual bone plates before and after tooth decompensation. The changes in the bone insertion level of maxillary and mandibular incisors in the present case encourage a reflection on the treatment protocol in individuals with dentoskeletal discrepancies.

  19. Polymorphic Alu insertions among Mayan populations.

    Science.gov (United States)

    Herrera, R J; Rojas, D P; Terreros, M C

    2007-01-01

    The Mayan homeland within Mesoamerica spans five countries: Belize, El Salvador, Guatemala, Honduras and Mexico. There are indications that the people we call the Maya migrated from the north to the highlands of Guatemala as early as 4000 B.C. Their existence was village-based and agricultural. The culture of these Preclassic Mayans owes much to the earlier Olmec civilization, which flourished in the southern portion of North America. In this study, four different Mayan groups were examined to assess their genetic variability. Ten polymorphic Alu insertion (PAI) loci were employed to ascertain the genetic affinities among these Mayan groups. North American, African, European and Asian populations were also examined as reference populations. Our results suggest that the Mayan groups examined in this study are not genetically homogeneous.

  20. Reinforcing cast iron with composite insert

    Directory of Open Access Journals (Sweden)

    Dulska A.

    2017-03-01

    Full Text Available The paper presents a proprietary method of making composite cast iron (eutectic locally reinforced with ceramics. The research included making casts with a ceramic layer, its percentage of the surface was 30%. The research included abrasive wear resistance according to ASTM G 65-00. As a result of the research it has been found that the infiltration of the molten metal into the ceramic preform mainly affects the correct production of the cast with local reinforcement. The research results also have proven that the application of a lattice ceramic insert placed in the mould is the most appropriate option, due to the even distribution of the particles in the cast and obtaining a sound cast.

  1. Regulatory perspective on incomplete control rod insertions

    Energy Technology Data Exchange (ETDEWEB)

    Chatterton, M.

    1997-01-01

    The incomplete control rod insertions experienced at South Texas Unit 1 and Wolf Creek are of safety concern to the NRC staff because they represent potential precursors to loss of shutdown margin. Even before it was determined if these events were caused by the control rods or by the fuel there was an apparent correlation of the problem with high burnup fuel. It was determined that there was also a correlation between high burnup and high drag forces as well as with rod drop time histories and lack of rod recoil. The NRC staff initial actions were aimed at getting a perspective on the magnitude of the problem as far as the number of plants and the amount of fuel that could be involved, as well as the safety significance in terms of shutdown margin. As tests have been performed and data has been analyzed the focus has shifted more toward understanding the problem and the ways to eliminate it. At this time the staff`s understanding of the phenomena is that it was a combination of factors including burnup, power history and temperature. The problem appears to be very sensitive to these factors, the interaction of which is not clearly understood. The model developed by Westinghouse provides a possible explanation but there is not sufficient data to establish confidence levels and sensitivity studies involving the key parameters have not been done. While several fixes to the problem have been discussed, no definitive fixes have been proposed. Without complete understanding of the phenomena, or fixes that clearly eliminate the problem the safety concern remains. The safety significance depends on the amount of shutdown margin lost due to incomplete insertion of the control rods. Were the control rods to stick high in the core, the reactor could not be shutdown by the control rods and other means such as emergency boration would be required.

  2. Automated insertion of preformed cochlear implant electrodes: evaluation of curling behaviour and insertion forces on an artificial cochlear model.

    Science.gov (United States)

    Rau, Thomas S; Hussong, Andreas; Leinung, Martin; Lenarz, Thomas; Majdani, Omid

    2010-03-01

    As a substantial part of our concept of a minimally invasive cochlear implant (CI) surgery, we developed an automated insertion tool. Studies on an artificial scala tympani model were performed in order to evaluate force application when using the insertion tool. Contour electrodes were automatically inserted into a transparent cochlea model in Advance Off-Stylet technique. Occurring forces were measured by the use of a load cell and correlated with observed intracochlear movement of the electrode carriers. Mean insertion forces were measured up to 20 mN comparable to previous studies on temporal bones. The most influencing factor is the implant's 2D curling behaviour in comparison to the 3D helical shape of the cochlea. The study confirms the functionality and reliability of the automated insertion tool for insertion of preformed CI. Improved insertion strategies considering patient-specific anatomy become possible.

  3. (MTT) dye reduction assay.

    African Journals Online (AJOL)

    to inhibit proliferation of HeLa cells was determined using the 3443- dimethylthiazol-2-yl)-2,5-diphenyl-tetrazolium bromide (MTT) dye reduction assay. Extracts from roots of Agathisanthemum bojeri, Synaptolepis kirkii and Zanha africana and the leaf extract of Physalis peruviana at a concentration of 10 pg/ml inhibited cell ...

  4. Hyaluronic Acid Assays

    DEFF Research Database (Denmark)

    Itenov, Theis S; Kirkby, Nikolai S; Bestle, Morten H

    2015-01-01

    BACKGROUD: Hyaluronic acid (HA) is proposed as a marker of functional liver capacity. The aim of the present study was to compare a new turbidimetric assay for measuring HA with the current standard method. METHODS: HA was measured by a particle-enhanced turbidimetric immunoassay (PETIA) and enzyme...

  5. The loss-of-allele assay for ES cell screening and mouse genotyping.

    Science.gov (United States)

    Frendewey, David; Chernomorsky, Rostislav; Esau, Lakeisha; Om, Jinsop; Xue, Yingzi; Murphy, Andrew J; Yancopoulos, George D; Valenzuela, David M

    2010-01-01

    Targeting vectors used to create directed mutations in mouse embryonic stem (ES) cells consist, in their simplest form, of a gene for drug selection flanked by mouse genomic sequences, the so-called homology arms that promote site-directed homologous recombination between the vector and the target gene. The VelociGene method for the creation of targeted mutations in ES cells employs targeting vectors, called BACVecs, that are based on bacterial artificial chromosomes. Compared with conventional short targeting vectors, BacVecs provide two major advantages: (1) their much larger homology arms promote high targeting efficiencies without the need for isogenicity or negative selection strategies; and (2) they enable deletions and insertions of up to 100kb in a single targeting event, making possible gene-ablating definitive null alleles and other large-scale genomic modifications. Because of their large arm sizes, however, BACVecs do not permit screening by conventional assays, such as long-range PCR or Southern blotting, that link the inserted targeting vector to the targeted locus. To exploit the advantages of BACVecs for gene targeting, we inverted the conventional screening logic in developing the loss-of-allele (LOA) assay, which quantifies the number of copies of the native locus to which the mutation was directed. In a correctly targeted ES cell clone, the LOA assay detects one of the two native alleles (for genes not on the X or Y chromosome), the other allele being disrupted by the targeted modification. We apply the same principle in reverse as a gain-of-allele assay to quantify the copy number of the inserted targeting vector. The LOA assay reveals a correctly targeted clone as having lost one copy of the native target gene and gained one copy of the drug resistance gene or other inserted marker. The combination of these quantitative assays makes LOA genotyping unequivocal and amenable to automated scoring. We use the quantitative polymerase chain reaction

  6. Trends in packaged steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Ganapathy, V. [ABCO Industries, Abilene, TX (United States)

    1996-09-01

    Oil and gas-fired packaged steam generators are used in many industrial plants. They generate saturated or superheated steam up to 250,000 lb/hr, 1000 psig, and 950 F. They may be used for continuous steam generation or as standby boilers in cogeneration systems. Numerous variables affect the design of this equipment. A few important considerations should be addressed at an early point by the plant engineer specifying or evaluating equipment options. These considerations include trends such as customized designs that minimize operating costs and ensure emissions regulations are met. The paper discusses efficiency considerations first.

  7. Identification of pathogenic retrotransposon insertions in cancer predisposition genes.

    Science.gov (United States)

    Qian, Yaping; Mancini-DiNardo, Debora; Judkins, Thaddeus; Cox, Hannah C; Brown, Krystal; Elias, Maria; Singh, Nanda; Daniels, Courtney; Holladay, Jayson; Coffee, Bradford; Bowles, Karla R; Roa, Benjamin B

    2017-10-01

    Cancer risks have been previously reported for some retrotransposon element (RE) insertions; however, detection of these insertions is technically challenging and very few oncogenic RE insertions have been reported. Here we evaluate RE insertions identified during hereditary cancer genetic testing using a comprehensive testing strategy. Individuals who had single-syndrome or pan-cancer hereditary cancer genetic testing from February 2004 to March 2017 were included. RE insertions were identified using Sanger sequencing, Next Generation Sequencing, or multiplex quantitative PCR, and further characterized using targeted PCR and sequencing analysis. Personal cancer history, ancestry, and haplotype were evaluated. A total of 37 unique RE insertions were identified in 10 genes, affecting 211 individuals. BRCA2 accounted for 45.9% (17/37) of all unique RE insertions. Several RE insertions were detected with high frequency in populations of conserved ancestry wherein up to 100% of carriers shared a high degree of haplotype conservation, suggesting founder effects. Our comprehensive testing strategy resulted in a substantial increase in the number of reported oncogenic RE insertions, several of which may have possible founder effects. Collectively, these data show that the detection of RE insertions is an important component of hereditary cancer genetic testing and may be more prevalent than previously reported. Copyright © 2017 Myriad Genetics, Inc. Published by Elsevier Inc. All rights reserved.

  8. Safety evaluation for packaging (onsite) for concrete-shielded RHTRU waste drum for the 327 postirradiation testing laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Adkins, H.E.

    1996-10-29

    This safety evaluation for packaging authorizes onsite transport of Type B quantities of radioactive material in the Concrete- Shielded Remote-Handled Transuranic Waste (RH TRU) Drum per WHC-CM-2-14, Hazardous Material Packaging and Shipping. The drum will be used for transport of 327 Building legacy waste from the 300 Area to the Transuranic Waste Storage and Assay Facility in the 200 West Area and on to a Solid Waste Storage Facility, also in the 200 Area.

  9. The Innovative Approaches to Packaging – Comparison Analysis of Intelligent and Active Packaging Perceptions in Slovakia

    Directory of Open Access Journals (Sweden)

    Loucanova Erika

    2017-06-01

    Full Text Available Packaging has always served a practical function - to hold goods together and protect it when moving toward the customer through distribution channel. Today packaging is also a container for promoting the product and making it easier and safer to use. The sheer importance of packaging functions is still growing and consequently the interest of the company is to access to the packaging more innovative and creative. The paper deals with the innovative approaches to packaging resulting in the creation of packaging with interactive active features in the form of active and intelligent packaging. Using comparative analysis, we monitored the perception of the active packaging functions in comparison to intelligent packaging function among different age categories. We identified the age categories which are most interested in these functions.

  10. Comparison of environmental sustainability of pharmaceutical packaging

    Directory of Open Access Journals (Sweden)

    Geo Raju

    2016-09-01

    Full Text Available Pharmaceutical companies are increasingly imparting a lot of importance on becoming more sustainable by developing medicines that are having same medicinal value but with reduced environmental impact. Type of packaging of tablets affects the emission generated during packaging of medicines. Selection of an appropriate packaging of medicine also influences the emission added to the environment. This paper aims at the comparison of environmental impacts of two different types of packaging of tablets viz., PVC blister and aluminium blister packaging. Life cycle assessment (LCA methodology is used for this comparison. The study includes stages from Cradle to Gate that is, extraction till the packaging processes focused mainly on manufacturing. The functional unit is taken as material required for packing 1 lakh (100,000, 500 mg of paracetamol tablets. Primary data is provided by a pharmaceutical formulation industry and secondary data is obtained from a commercial LCA database available in GaBi and from literature. LCA software GaBi 7.0 is used to carry out the life cycle assessment of both kinds of packaging. Life cycle impact assessment (LCIA method, CML 2001, is used in this study. The study indicates that the PVC blister packaging performs better compared to the aluminium blister packaging in most of the impact categories considered. It is observed that the process of manufacturing of aluminium foils is a significant contributor to the overall environmental impact of aluminium blister packaging.

  11. Challenges in the Packaging of MEMS

    Energy Technology Data Exchange (ETDEWEB)

    BROWN, WILLIAM D.; EATON, WILLIAM P.; MALSHE, AJAY P.; MILLER, WILLIAM M.; O' NEAL, CHAD; SINGH, SUSHILA B.

    1999-09-24

    Microelectromechanical Systems (MEMS) packaging is much different from conventional integrated circuit (IC) packaging. Many MEMS devices must interface to the environment in order to perform their intended function, and the package must be able to facilitate access with the environment while protecting the device. The package must also not interfere with or impede the operation of the MEMS device. The die attachment material should be low stress, and low outgassing, while also minimizing stress relaxation overtime which can lead to scale factor shifts in sensor devices. The fabrication processes used in creating the devices must be compatible with each other, and not result in damage to the devices. Many devices are application specific requiring custom packages that are not commercially available. Devices may also need media compatible packages that can protect the devices from harsh environments in which the MEMS device may operate. Techniques are being developed to handle, process, and package the devices such that high yields of functional packaged parts will result. Currently, many of the processing steps are potentially harmful to MEMS devices and negatively affect yield. It is the objective of this paper to review and discuss packaging challenges that exist for MEMS systems and to expose these issues to new audiences from the integrated circuit packaging community.

  12. The Ig heavy chain switch region is a hotspot for insertion of transfected DNA

    Energy Technology Data Exchange (ETDEWEB)

    Baar, J.; Shulman, M.J. [Univ. of Toronto, Ontario (Canada)

    1995-08-15

    The Ig heavy chain switch usually occurs by breaking and rejoining DNA in the switch (S) regions, which consist of tandemly repeated sequences 5{prime} of the constant region exons. Various studies have suggested that S DNA can also recombine with non-S sequences. To measure the frequency of such recombination events, the hybridoma cell line igm692, a deletion mutant that lacks the C{mu}1 and C{mu}2 exons and the 3{prime} end of the S{mu} region, was transfected with a fragment bearing the C{mu}1-2 exons, but no S{mu} DNA. Insertion of this fragment into the residual VDJ-C{mu} intron of igm692 can restore a functional {mu} gene, yielding a transformant that is detected as a plaque-forming cell (PFC). PFCs comprise {approximately}8 x 10{sup -7} of the surviving transfected cells. In 10 of 12 PFCs, the C{mu}1-2 fragment inserted into the 2.5-kb residual S{mu} region, whereas insertion in two cases occurred in the 3.5-kb segment 5{prime} of S{mu}. Using a PCR assay to measure the frequency of insertion of the tranferred fragment elsewhere in the hybridoma genome, we found that {approximately}9% of the surviving tranfected cells had stably acquired the C{mu}1-2 fragment. These results indicate that the S{mu} region is {approximately}100-fold more recombinogenic than the average genomic site, and {approximately}7-fold more recombinogenic than the non-S{mu} segment of the residual VDJ-C{mu}, i.e., the S{mu} region is a hotspot for insertion of transfected DNA.

  13. Whole genome computational comparative genomics: A fruitful approach for ascertaining Alu insertion polymorphisms.

    Science.gov (United States)

    Wang, Jianxin; Song, Lei; Gonder, M Katherine; Azrak, Sami; Ray, David A; Batzer, Mark A; Tishkoff, Sarah A; Liang, Ping

    2006-01-03

    Alu elements are the most active and predominant type of short interspersed elements (SINEs) in the human genome. Recently inserted polymorphic (for presence/absence) Alu elements contribute to genome diversity among different human populations, and they are useful genetic markers for population genetic studies. The objective of this study is to identify polymorphic Alu insertions through an in silico comparative genomics approach and to analyze their distribution pattern throughout the human genome. By computationally comparing the public and Celera sequence assemblies of the human genome, we identified a total of 800 polymorphic Alu elements. We used polymerase chain reaction-based assays to screen a randomly selected set of 16 of these 800 Alu insertion polymorphisms using a human diversity panel to demonstrate the efficiency of our approach. Based on sequence analysis of the 800 Alu polymorphisms, we report three new Alu subfamilies, Ya3, Ya4b, and Yb11, with Yb11 being the smallest known Alu subfamily. Analysis of retrotransposition activity revealed Yb11, Ya8, Ya5, Yb9, and Yb8 as the most active Alu subfamilies and the maintenance of a very low level of retrotransposition activity or recent gene conversion events involving S subfamilies. The 800 polymorphic Alu insertions are characterized by the presence of target site duplications (TSDs) and longer than average polyA-tail length. Their pre-integration sites largely follow an extended "NT-AARA" motif. Among chromosomes, the density of Alu insertion polymorphisms is positively correlated with the Alu-site availability and is inversely correlated with the densities of older Alu elements and genes.

  14. Natural biopolimers in organic food packaging

    Science.gov (United States)

    Wieczynska, Justyna; Cavoski, Ivana; Chami, Ziad Al; Mondelli, Donato; Di Donato, Paola; Di Terlizzi, Biagio

    2014-05-01

    Concerns on environmental and waste problems caused by use of non-biodegradable and non-renewable based plastic packaging have caused an increase interest in developing biodegradable packaging using renewable natural biopolymers. Recently, different types of biopolymers like starch, cellulose, chitosan, casein, whey protein, collagen, egg white, soybean protein, corn zein, gelatin and wheat gluten have attracted considerable attention as potential food packaging materials. Recyclable or biodegradable packaging material in organic processing standards is preferable where possible but specific principles of packaging are not precisely defined and standards have to be assessed. There is evidence that consumers of organic products have specific expectations not only with respect to quality characteristics of processed food but also in social and environmental aspects of food production. Growing consumer sophistication is leading to a proliferation in food eco-label like carbon footprint. Biopolymers based packaging for organic products can help to create a green industry. Moreover, biopolymers can be appropriate materials for the development of an active surfaces designed to deliver incorporated natural antimicrobials into environment surrounding packaged food. Active packaging is an innovative mode of packaging in which the product and the environment interact to prolong shelf life or enhance safety or sensory properties, while maintaining the quality of the product. The work will discuss the various techniques that have been used for development of an active antimicrobial biodegradable packaging materials focusing on a recent findings in research studies. With the current focus on exploring a new generation of biopolymer-based food packaging materials with possible applications in organic food packaging. Keywords: organic food, active packaging, biopolymers , green technology

  15. WASTE PACKAGE DESIGN SENSITIVITY REPORT

    Energy Technology Data Exchange (ETDEWEB)

    P. Mecharet

    2001-03-09

    The purpose of this technical report is to present the current designs for waste packages and determine which designs will be evaluated for the Site Recommendation (SR) or Licence Application (LA), to demonstrate how the design will be shown to comply with the applicable design criteria. The evaluations to support SR or LA are based on system description document criteria. The objective is to determine those system description document criteria for which compliance is to be demonstrated for SR; and, having identified the criteria, to refer to the documents that show compliance. In addition, those system description document criteria for which compliance will be addressed for LA are identified, with a distinction made between two steps of the LA process: the LA-Construction Authorization (LA-CA) phase on one hand, and the LA-Receive and Possess (LA-R&P) phase on the other hand. The scope of this work encompasses the Waste Package Project disciplines for criticality, shielding, structural, and thermal analysis.

  16. Ocular inserts - Advancement in therapy of eye diseases

    Directory of Open Access Journals (Sweden)

    Anita Kumari

    2010-01-01

    Full Text Available The ocular insert represents a significant advancement in the therapy of eye disease. Ocular inserts are defined as sterile, thin, multilayered, drug-impregnated, solid or semisolid consistency devices placed into the cul-de-sac or conjuctival sac, whose size and shape are especially designed for ophthalmic application. They are composed of a polymeric support that may or may not contain a drug. The drug can later be incorporated as dispersion or a solution in the polymeric support. They offer several advantages as increased ocular residence and sustained release of medication into the eye. The insert includes a body portion sized to position within a lachrymal canaliculus of the eyelid. The inserts are classified according to their solubility as insoluble, soluble, or bioerodible inserts. The release of drug from the insert depends upon the diffusion, osmosis, and bioerosion of the drug, and this article is an attempt to present a brief about this newer drug delivery system.

  17. Insertion torque versus mechanical resistance of mini-implants inserted in different cortical thickness

    Science.gov (United States)

    Santos, Renata de Faria; Ruellas, Antonio Carlos de Oliveira; Fernandes, Daniel Jogaib; Elias, Carlos Nelson

    2014-01-01

    Objective This study aimed to measure insertion torque, tip mechanical resistance to fracture and transmucosal neck of mini-implants (MI) (Conexão Sistemas de PróteseT), as well as to analyze surface morphology. Methods Mechanical tests were carried out to measure the insertion torque of MIs in different cortical thicknesses, and tip mechanical resistance to fracture as well as transmucosal neck of MIs. Surface morphology was assessed by scanning electron microscopy (SEM) before and after the mechanical tests. Results Values of mechanical resistance to fracture (22.14 N.cm and 54.95 N.cm) were higher and statistically different (P 0.05) to torsional fracture in the tip of MI (22.14 N.cm) when 3 mm cortical thickness (16.11 N.cm) and dense bone (23.95 N.cm) were used. Torsional fracture of the transmucosal neck (54.95 N.cm) was higher and statistically different (P mini-implants tested presented adequate surface morphology. The resistance of mini-implants to fracture safely allows placement in 1 and 2-mm cortical thickness. However, in 3-mm cortical thickness and dense bones, pre-drilling with a bur is recommended before insertion. PMID:25162571

  18. Development of Multifunctional Active Film and Its Application in Modified Atmosphere Packaging of Shiitake Mushrooms.

    Science.gov (United States)

    Wang, Hong Jiang; An, Duck Soon; Lee, Dong Sun

    2016-09-01

    Agar-based films with multiple functions (CO2 absorption, water vapor absorption, and antimicrobial activity) were developed, tested for their properties, and then applied to the packaging of fresh shiitake mushrooms as an insert label. The films were cast from an agar-based aqueous solution containing a dissolving plasticizer (glycerol), a CO2 absorbent (sodium carbonate [SC] alone or a combination of SC and sodium glycinate [SC-SG]), and a volatile antimicrobial agent (carvacrol [CRV]). The agar of the film matrix is designed to serve as a water vapor absorbent. The multifunctional films tended to have poor mechanical properties, with a hard texture and an opaque and yellowish color. The CO2 absorbent, either SC alone or SC-SG, affected CRV retention and release along with the CO2 and water vapor absorption behavior. Both films (SC-CRV and SC-SG-CRV films) showed good inhibitory effects against Pseudomonas fluorescens and Saccharomyces cerevisiae . SC-CRV film had a higher and faster CO2 absorption property, higher retention and extended release of CRV, and lower and slower water vapor absorption and was assessed to be better suited for use in shiitake mushroom packaging. The packaging in which the SC-CRV film with an appropriate amount of CRV was used as an insert label was able to generate the desired atmosphere and less moisture condensation inside the package, producing the best preservation of quality in terms of mushroom color, firmness, flavor score, and microbial counts after 6 days of storage at 10°C. A tailored modified atmosphere packaging system using multifunctional film would be useful in the preservation of CO2-sensitive fresh commodities.

  19. Genetic damage in oligozoospermic patients detected by fluorescence in-situ hybridization, inverse restriction site mutation assay, sperm chromatin structure assay and the Comet assay.

    Science.gov (United States)

    Schmid, T E; Kamischke, A; Bollwein, H; Nieschlag, E; Brinkworth, M H

    2003-07-01

    The possibility that oligozoospermic men may have elevated levels of genetic damage in their sperm is of particular concern as they could transmit defects to their offspring. Sperm samples were obtained from 12 infertile, oligozoospermic patients and 12 healthy normozoospermic volunteers. Fluorescence in-situ hybridization (FISH) was used to determine aneuploidy rates in sperm and inverse restriction site mutation (iRSM) assay to determine gene mutations; defective chromatin packaging was quantified by sperm chromatin structure assay (SCSA) and DNA strand breaks by the Comet assay. FISH analysis showed a significant increase in gonosomal X,Y,18 (P sperm with X,Y,18,18 (P sperm chromatin was found in the infertility patients compared with the control group using the SCSA assay. In the Comet assay, a significant increase (P assay. The data indicate that infertile oligozoospermic men have an elevated level of XY aneuploidy and XY diploidy in the germ-line, as well as elevated levels of sperm chromatin disturbances and sperm DNA strand breaks. These data demonstrate that oligozoospermic infertility patients show several different types of genetic damage in their sperm. Thus, such men appear to have defects at a variety of levels of spermatogenesis and their infertility may not just be a result of the oligozoospermia.

  20. Reliability of CGA/LGA/HDI Package Board/Assembly (Final Report)

    Science.gov (United States)

    Ghaffaroam. Reza

    2014-01-01

    Package manufacturers are now offering commercial-off-the-shelf column grid array (COTS CGA) packaging technologies in high-reliability versions. Understanding the process and quality assurance (QA) indicators for reliability are important for low-risk insertion of these advanced electronics packages. The previous reports, released in January of 2012 and January of 2013, presented package test data, assembly information, and reliability evaluation by thermal cycling for CGA packages with 1752, 1517, 1509, and 1272 inputs/outputs (I/Os) and 1-mm pitch. It presented the thermal cycling (-55C either 100C or 125C) test results for up to 200 cycles. This report presents up to 500 thermal cycles with quality assurance and failure analysis evaluation represented by optical photomicrographs, 2D real time X-ray images, dye-and-pry photomicrographs, and optical/scanning electron Microscopy (SEM) cross-sectional images. The report also presents assembly challenge using reflowing by either vapor phase or rework station of CGA and land grid array (LGA) versions of three high I/O packages both ceramic and plastic configuration. A new test vehicle was designed having high density interconnect (HDI) printed circuit board (PCB) with microvia-in-pad to accommodate both LGA packages as well as a large number of fine pitch ball grid arrays (BGAs). The LGAs either were assembled onto HDI PCB as an LGA or were solder paste print and reflow first to form solder dome on pads before assembly. Both plastic BGAs with 1156 I/O and ceramic LGAs were assembled. It also presented the X-ray inspection results as well as failures due to 200 thermal cycles. Lessons learned on assembly of ceramic LGAs are also presented.

  1. NFR TRIGA package design review report

    Energy Technology Data Exchange (ETDEWEB)

    Clements, M.D.

    1994-08-26

    The purpose of this document is to compile, present and document the formal design review of the NRF TRIGA packaging. The contents of this document include: the briefing meeting presentations, package description, design calculations, package review drawings, meeting minutes, action item lists, review comment records, final resolutions, and released drawings. This design review required more than two meeting to resolve comments. Therefore, there are three meeting minutes and two action item lists.

  2. Global assays of fibrinolysis.

    Science.gov (United States)

    Ilich, A; Bokarev, I; Key, N S

    2017-10-01

    Fibrinolysis is an important and integral part of the hemostatic system. Acting as a balance to blood coagulation, the fibrinolytic system protects the body from unwanted thrombus formation and occlusion of blood vessels. As long as blood coagulation and fibrinolysis remain in equilibrium, response to injury, such as vessel damage, is appropriately regulated. However, alterations in this balance may lead to thrombosis or bleeding. A variety of methods have been proposed to assess fibrinolytic activity in blood or its components, but due to the complexity of the system, the design of a "gold standard" assay that reflects overall fibrinolysis has remained an elusive goal. In this review, we describe the most commonly used methods that have been described, such as thromboelastography (TEG and ROTEM), global fibrinolytic capacity in plasma and whole blood, plasma turbidity methods, simultaneous thrombin and plasmin generation assays, euglobulin clot lysis time and fibrin plate methods. All of these assays have strengths and limitations. We suggest that some methods may be preferable for detecting hypofibrinolytic conditions, whereas others may be better for detecting hyperfibrinolytic states. © 2017 John Wiley & Sons Ltd.

  3. Effect of vibration frequency on biopsy needle insertion force.

    Science.gov (United States)

    Tan, Lei; Qin, Xuemei; Zhang, Qinhe; Zhang, Hongcai; Dong, Hongjian; Guo, Tuodang; Liu, Guowei

    2017-05-01

    Needle insertion is critical in many clinical medicine procedures, such as biopsy, brachytherapy, and injection therapy. A platform with two degrees of freedom was set up to study the effect of vibration frequency on needle insertion force. The gel phantom deformation at the needle cutting edge and the Voigt model are utilized to develop a dynamic model to explain the relationship between the insertion force and needle-tip velocity. The accuracy of this model was verified by performing needle insertions into phantom gel. The effect of vibration on insertion force can be explained as the vibration increasing the needle-tip velocity and subsequently increasing the insertion force. In a series of needle insertion experiments with different vibration frequencies, the peak forces were selected for comparison to explore the effect of vibration frequency on needle insertion force. The experimental results indicate that the insertion force at 500Hz increases up to 17.9% compared with the force at 50Hz. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  4. Hollow polymer microneedles array resistance and insertion tests.

    Science.gov (United States)

    Lhernould, Marion Sausse; Deleers, Michel; Delchambre, Alain

    2015-03-01

    Microneedles are developed in order to become the transdermal administration method of the future. They however still face numerous challenges. This paper addresses the challenge to effectively insert the microneedle arrays into membranes. A recently proposed model membrane and test method for microneedles insertion, published in International Journal of Pharmaceutics, is used in this aim. A moulded 4 by 4 hollow polymer microneedle array developed at the Université Libre de Bruxelles is tested for insertion using this model. Results show that the array is extremely resistant to insertion, it can withstand very high forces and even multiple insertions without blunting. Different insertion tests were performed on a folded in eight Parafilm® film because it exhibits excellent similarity to porcine skin. The insertion force, the insertion speed and the holding time of the array against membranes must be optimised in order to get efficient reliable insertions at, at least, 500μm depth. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. A New Configuration of Surface Acoustic Wave Intermediate-Frequency Filter with Compact Size and Improved Insertion Loss

    Science.gov (United States)

    Chung, Mei‑Hui; Wang, Shuming T.

    2006-02-01

    Size reduction is always a major challenge to surface acoustic wave (SAW) manufacturers. For some years, commercial SAW filter designers have been developing various configurations of SAW filters just to fit into a smaller package. In this work, a new single-phase unidirectional transducer (SPUDT) based intermediate-frequency (IF) filter with improved insertion loss and compact size is proposed. This filter has an architecture that combines electrode-width controlled single-phase unidirectional transducer (EWC-SPUDT) and comb-type SPUDT. As a result of this improvement, a filter for IF-filtering of Digital European Cordless Telephone (DECT) system can be squeezed into a surface-mount device (SMD) 7.0× 5.0 mm2 package. The performance of this filter even excels most commercial available IF filters in the same application.

  6. The ATLAS Insertable B-Layer Project

    CERN Document Server

    Miucci, A; The ATLAS collaboration

    2014-01-01

    The ATLAS experiment will upgrade its Pixel Detector with the installation of a new pixel layer in 2013-14. The new sub-detector, named Insertable B-layer (IBL), will be installed between the existing Pixel Detector and a new smaller radius beam-pipe at a radius of 3.3 cm. To cope with the high radiation and pixel occupancy due to the proximity to the interaction point, a new read-out chip and two different silicon sensor technologies (planar and 3D) have been de- veloped. Furthermore, the physics performance should be improved through the reduction of pixel size while a low material budget should be imposed. A new mechanical support using lightweight staves and a CO2 based cooling system is used. An overview of the IBL project and the status of the production of staves and the qualification of the assembly procedure, the loaded module electrical integrity and the read-out chain will be presented.

  7. Hermeticity testing of MEMS and microelectronic packages

    CERN Document Server

    Costello, Suzanne

    2013-01-01

    Packaging of microelectronics has been developing since the invention of the transistor in 1947. With the increasing complexity and decreasing size of the die, packaging requirements have continued to change. A step change in package requirements came with the introduction of the Micro-Electro-Mechanical System (MEMS) whereby interactions with the external environment are, in some cases, required.This resource is a rapid, definitive reference on hermetic packaging for the MEMS and microelectronics industry, giving practical guidance on traditional and newly developed test methods. This book in

  8. Photolithography and Micro-Fabrication/ Packaging Laboratories

    Data.gov (United States)

    Federal Laboratory Consortium — The Photolithography and Micro-Fabrication/Packaging laboratories provide research level semiconductor processing equipment and facilities that do not require a full...

  9. Best Practice in Policy Package Design

    DEFF Research Database (Denmark)

    Kessler, Florian; Vesela, Jirina; Vencl, Vaclav

    2010-01-01

    This deliverable focuses on the identification and analysis of best practice examples of policy package design. For this purpose a methodology is developed that allows the systematic analysis of both national and EU policy packages. Eight packages were selected and analysed, highlighting...... the factors which supported the design and implementation process in each case. The results of the analysis show which factors led to these cases to be considered best practice. In addition, factors are identified which are not yet part of the generic policy packaging framework presented in earlier OPTIC...

  10. Packaging performance evaluation and performance oriented packaging standards for large packages for poison inhalation hazard materials

    Energy Technology Data Exchange (ETDEWEB)

    Griego, N.R.; Mills, G.S.; McClure, J.D. [and others

    1997-07-01

    The U.S. Department of Transportation Research & Special Programs Administration (DOT-RSPA) has sponsored a project at Sandia National Laboratories to evaluate the protection provided by current packagings used for truck and rail transport of materials that have been classified as Poison Inhalation Hazards (PIH) and to recommend performance standards for these PIH packagings. Hazardous materials span a wide range of toxicity and there are many parameters used to characterize toxicity; for any given hazardous material, data are not available for all of the possible toxicity parameters. Therefore, it was necessary to select a toxicity criterion to characterize all of the PIH compounds (a value of the criterion was derived from other parameters in many cases) and to calculate their dispersion in the event of a release resulting from a transportation accident. Methodologies which account for material toxicity and dispersal characteristics were developed as a major portion of this project and applied to 72 PIH materials. This report presents details of the PIH material toxicity comparisons, calculation of their dispersion, and their classification into five severity categories. 16 refs., 5 figs., 7 tabs.

  11. The art of packaging: An investigation into the role of color in packaging, marketing, and branding

    National Research Council Canada - National Science Library

    Behzad Mohebbi

    2014-01-01

      The purpose of this study is to contribute to the existing research in the field of packaging and marketing and shed more light on the psychology of colors and their effect on packaging and marketing...

  12. PRIDE Surveillance Projects Data Packaging Project Information Package Specification Version 1.1

    Energy Technology Data Exchange (ETDEWEB)

    Kelleher, D. M.; Shipp, R. L.; Mason, J. D.

    2010-08-31

    Information Package Specification version 1.1 describes an XML document format called an information package that can be used to store information in information management systems and other information archives. An information package consists of package information, the context required to understand and use that information, package metadata that describes the information, and XML signatures that protect the information. The information package described in this specification was designed to store Department of Energy (DOE) and National Nuclear Security Administration (NNSA) information and includes the metadata required for that information: a unique package identifier, information marking that conforms to DOE and NNSA requirements, and access control metadata. It is an implementation of the Open Archival Information System (OAIS) Reference Model archival information package tailored to meet NNSA information storage requirements and designed to be used in the computing environments at the Y-12 National Security Complex and at other NNSA sites.

  13. The Innovative Approaches to Packaging – Comparison Analysis of Intelligent and Active Packaging Perceptions in Slovakia

    National Research Council Canada - National Science Library

    Erika Loucanova; Martina Kalamarova; Jan Parobek

    2017-01-01

    .... Using comparative analysis, we monitored the perception of the active packaging functions in comparison to intelligent packaging function among different age categories. We identified the age categories which are most interested in these functions.

  14. Advanced Sensor Arrays and Packaging

    Energy Technology Data Exchange (ETDEWEB)

    Ryter, John Wesley [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Romero, Christopher J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Ramaiyan, Kannan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Brosha, Eric L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-08-11

    Novel sensor packaging elements were designed, fabricated, and tested in order to facilitate the transition of electrochemical mixed-potential sensors toward commercialization. Of the two designs completed, the first is currently undergoing field trials, taking direct measurements within vehicle exhaust streams, while the second is undergoing preliminary laboratory testing. The sensors’ optimal operating conditions, sensitivity to hydrogen, and long-­term baseline stability were also investigated. The sensing capabilities of lanthanum chromite (La0.8Sr0.2CrO3) and indium-­doped tin oxide (ITO) working electrodes were compared, and the ITO devices were selected for pre-­commercial field trials testing at a hydrogen fuel cell vehicle fueling station in California. Previous data from that fueling station were also analyzed, and the causes of anomalous baseline drift were identified.

  15. Antimicrobial seafood packaging: a review.

    Science.gov (United States)

    Singh, Suman; Ho Lee, Myung; Park, Lnsik; Shin, Yangjai; Lee, Youn Suk

    2016-06-01

    Microorganisms are the major cause of spoilage in most seafood products; however, only few microbes, called the specific spoilage organisms (SSOs), contribute to the offensive off-flavors associated with seafood spoilage. In food, microbial degradation manifests itself as spoilage, or changes in the sensory properties of a food product, rendering it unsuitable for human consumption. The use of antimicrobial substances can control the general microflora as well as specific microorganisms related to spoilage to provide products with higher safety and better quality. Many antimicrobial compounds have been evaluated in film structures for use in seafood, especially organic acids and their salts, enzymes, bacteriocins; some studies have considered inorganic compounds such as AgSiO2, zinc oxide, silver zeolite, and titanium oxide. The characteristics of some organic antimicrobial packaging systems for seafood and their antimicrobial efficiency in film structures are reviewed in this article.

  16. Printing systems for MEMS packaging

    Science.gov (United States)

    Hayes, Donald J.; Cox, Weldon R.; Wallace, David B.

    2001-10-01

    Ink-jet printing technology is, in many ways, ideally suited for addressing a number of these MEMS device packaging challenges. The general advantages of this form of microdispensing derive from the incorporation of data-driven, non-contact processes which enable precise, picoliter-level volumes of material to be deposited with high accuracy and speed at target sites, even on non-planar surfaces. Being data-driven, microjet printing is a highly flexible and automated process which may readily be incorporated into manufacturing lines. It does not require application-specific tooling such as photomasks or screens, and, as an additive process with no chemical waste, it is environmentally friendly. In short, the advantages obtainable with incorporation of micro-jet printing technology in many fabrication applications range from increased process capability, integration and automation to reduced manufacturing costs.

  17. Structure and Function Study of Phi29 DNA packaging motor

    Science.gov (United States)

    Fang, Huaming

    A powerful nanomotor is employed by the tailed dsDNA virus to package the genome into a preformed protein shell during the process of replication. The bacteriophage phi29 is an excellent model for investigating the viral DNA packaging mechanism. The phi29 DNA packaging motor is composed of three ring structures: the dodecameric connector ring, the hexameric pRNA ring and the hexameric ATPase gp16 ring. The connector is the central hub for the DNA to enter and to exit. There are four positively charged lysine rings scattered inside the highly negatively charged connector channel. It is speculated that these positive charged lysine rings may play active roles during DNA packaging in many models. To test this prevalent view, the basic lysine residues were mutated to neutral alanines and the pH environment was altered. Amazingly, the results were beyond expectation. Neither the DNA translocation nor the one-way traffic property of the channel were measurably influenced by the alteration of the charge of lysine residues when the basic lysine residues mutated to neutral alanines or the pH environment changed to acid or basic. The ATPase or the terminase is the central part of the viral DNA packaging motor. The phi29 ATPase is highly hydrophobic and tends to aggregate in solution. A green fluorescent protein tag (eGFP) fused to the N-terminus of gp16 enhanced its solubility and stability. The eGFP-gp16 showed similar activity to wild type gp16 and was easily detected by fluorescent instruments. The interaction between eGFP-gp16 and DNA in the various conditions were investigated by electrophoretic mobility shift assay, FRET and sucrose gradient. gamma-S-ATP dramatically increased gp16 binding affinity to DNA and ATP, ADP, phosphate could release gp16 from gp16-DNA-gamma-S-ATP complex. The sliding of gp16 out of the gp16-DNA-gamma-S-ATP complex could be blocked by addition of Steptavidin to ends of dsDNA which is conjugated with biotins. Also, we found that six eGFP-gp16

  18. From Cells to Virus Particles: Quantitative Methods to Monitor RNA Packaging

    Directory of Open Access Journals (Sweden)

    Mireia Ferrer

    2016-08-01

    Full Text Available In cells, positive strand RNA viruses, such as Retroviridae, must selectively recognize their full-length RNA genome among abundant cellular RNAs to assemble and release particles. How viruses coordinate the intracellular trafficking of both RNA and protein components to the assembly sites of infectious particles at the cell surface remains a long-standing question. The mechanisms ensuring packaging of genomic RNA are essential for viral infectivity. Since RNA packaging impacts on several essential functions of retroviral replication such as RNA dimerization, translation and recombination events, there are many studies that require the determination of RNA packaging efficiency and/or RNA packaging ability. Studies of RNA encapsidation rely upon techniques for the identification and quantification of RNA species packaged by the virus. This review focuses on the different approaches available to monitor RNA packaging: Northern blot analysis, ribonuclease protection assay and quantitative reverse transcriptase-coupled polymerase chain reaction as well as the most recent RNA imaging and sequencing technologies. Advantages, disadvantages and limitations of these approaches will be discussed in order to help the investigator to choose the most appropriate technique. Although the review was written with the prototypic simple murine leukemia virus (MLV and complex human immunodeficiency virus type 1 (HIV-1 in mind, the techniques were described in order to benefit to a larger community.

  19. Nanotechnology: An Untapped Resource for Food Packaging

    Directory of Open Access Journals (Sweden)

    Chetan Sharma

    2017-09-01

    Full Text Available Food commodities are packaged and hygienically transported to protect and preserve them from any un-acceptable alteration in quality, before reaching the end-consumer. Food packaging continues to evolve along-with the innovations in material science and technology, as well as in light of consumer's demand. Presently, the modern consumers of competitive economies demands for food with natural quality, assured safety, minimal processing, extended shelf-life and ready-to-eat concept. Innovative packaging systems, not only ascertains transit preservation and effective distribution, but also facilitates communication at the consumer levels. The technological advances in the domain of food packaging in twenty-first century are mainly chaired by nanotechnology, the science of nano-materials. Nanotechnology manipulates and creates nanometer scale materials, of commercial and scientific relevance. Introduction of nanotechnology in food packaging sector has significantly addressed the food quality, safety and stability concerns. Besides, nanotechnology based packaging intimate's consumers about the real time quality of food product. Additionally, nanotechnology has been explored for controlled release of preservatives/antimicrobials, extending the product shelf life within the package. The promising reports for nanotechnology interventions in food packaging have established this as an independent priority research area. Nanoparticles based food packages offer improved barrier and mechanical properties, along with food preservation and have gained welcoming response from market and end users. In contrary, recent advances and up-liftment in this area have raised various ethical, environmental and safety concerns. Policies and regulation regarding nanoparticles incorporation in food packaging are being reviewed. This review presents the existing knowledge, recent advances, concerns and future applications of nanotechnology in food packaging sector.

  20. Nanotechnology: An Untapped Resource for Food Packaging.

    Science.gov (United States)

    Sharma, Chetan; Dhiman, Romika; Rokana, Namita; Panwar, Harsh

    2017-01-01

    Food commodities are packaged and hygienically transported to protect and preserve them from any un-acceptable alteration in quality, before reaching the end-consumer. Food packaging continues to evolve along-with the innovations in material science and technology, as well as in light of consumer's demand. Presently, the modern consumers of competitive economies demands for food with natural quality, assured safety, minimal processing, extended shelf-life and ready-to-eat concept. Innovative packaging systems, not only ascertains transit preservation and effective distribution, but also facilitates communication at the consumer levels. The technological advances in the domain of food packaging in twenty-first century are mainly chaired by nanotechnology, the science of nano-materials. Nanotechnology manipulates and creates nanometer scale materials, of commercial and scientific relevance. Introduction of nanotechnology in food packaging sector has significantly addressed the food quality, safety and stability concerns. Besides, nanotechnology based packaging intimate's consumers about the real time quality of food product. Additionally, nanotechnology has been explored for controlled release of preservatives/antimicrobials, extending the product shelf life within the package. The promising reports for nanotechnology interventions in food packaging have established this as an independent priority research area. Nanoparticles based food packages offer improved barrier and mechanical properties, along with food preservation and have gained welcoming response from market and end users. In contrary, recent advances and up-liftment in this area have raised various ethical, environmental and safety concerns. Policies and regulation regarding nanoparticles incorporation in food packaging are being reviewed. This review presents the existing knowledge, recent advances, concerns and future applications of nanotechnology in food packaging sector.

  1. Healthy package, healthy product? Effects of packaging design as a function of purchase setting

    NARCIS (Netherlands)

    van Rompay, Thomas Johannes Lucas; Deterink, Florien; Fenko, Anna

    2016-01-01

    Inspired by research testifying to the influence of visual packaging appearance and meaning portrayal on food evaluation, here it is argued that effects of packaging design vary depending on purchase context. Realistic packaging variants for a fictitious yoghurt brand varying in health connotation

  2. Generation and analysis of a barcode-tagged insertion mutant library in the fission yeast Schizosaccharomyces pombe

    Science.gov (United States)

    2012-01-01

    Background Barcodes are unique DNA sequence tags that can be used to specifically label individual mutants. The barcode-tagged open reading frame (ORF) haploid deletion mutant collections in the budding yeast Saccharomyces cerevisiae and the fission yeast Schizosaccharomyces pombe allow for high-throughput mutant phenotyping because the relative growth of mutants in a population can be determined by monitoring the proportions of their associated barcodes. While these mutant collections have greatly facilitated genome-wide studies, mutations in essential genes are not present, and the roles of these genes are not as easily studied. To further support genome-scale research in S. pombe, we generated a barcode-tagged fission yeast insertion mutant library that has the potential of generating viable mutations in both essential and non-essential genes and can be easily analyzed using standard molecular biological techniques. Results An insertion vector containing a selectable ura4+ marker and a random barcode was used to generate a collection of 10,000 fission yeast insertion mutants stored individually in 384-well plates and as six pools of mixed mutants. Individual barcodes are flanked by Sfi I recognition sites and can be oligomerized in a unique orientation to facilitate barcode sequencing. Independent genetic screens on a subset of mutants suggest that this library contains a diverse collection of single insertion mutations. We present several approaches to determine insertion sites. Conclusions This collection of S. pombe barcode-tagged insertion mutants is well-suited for genome-wide studies. Because insertion mutations may eliminate, reduce or alter the function of essential and non-essential genes, this library will contain strains with a wide range of phenotypes that can be assayed by their associated barcodes. The design of the barcodes in this library allows for barcode sequencing using next generation or standard benchtop cloning approaches. PMID:22554201

  3. Generation and analysis of a barcode-tagged insertion mutant library in the fission yeast Schizosaccharomyces pombe

    Directory of Open Access Journals (Sweden)

    Chen Bo-Ruei

    2012-05-01

    Full Text Available Abstract Background Barcodes are unique DNA sequence tags that can be used to specifically label individual mutants. The barcode-tagged open reading frame (ORF haploid deletion mutant collections in the budding yeast Saccharomyces cerevisiae and the fission yeast Schizosaccharomyces pombe allow for high-throughput mutant phenotyping because the relative growth of mutants in a population can be determined by monitoring the proportions of their associated barcodes. While these mutant collections have greatly facilitated genome-wide studies, mutations in essential genes are not present, and the roles of these genes are not as easily studied. To further support genome-scale research in S. pombe, we generated a barcode-tagged fission yeast insertion mutant library that has the potential of generating viable mutations in both essential and non-essential genes and can be easily analyzed using standard molecular biological techniques. Results An insertion vector containing a selectable ura4+ marker and a random barcode was used to generate a collection of 10,000 fission yeast insertion mutants stored individually in 384-well plates and as six pools of mixed mutants. Individual barcodes are flanked by Sfi I recognition sites and can be oligomerized in a unique orientation to facilitate barcode sequencing. Independent genetic screens on a subset of mutants suggest that this library contains a diverse collection of single insertion mutations. We present several approaches to determine insertion sites. Conclusions This collection of S. pombe barcode-tagged insertion mutants is well-suited for genome-wide studies. Because insertion mutations may eliminate, reduce or alter the function of essential and non-essential genes, this library will contain strains with a wide range of phenotypes that can be assayed by their associated barcodes. The design of the barcodes in this library allows for barcode sequencing using next generation or standard benchtop cloning

  4. Radon assay for SNO+

    Energy Technology Data Exchange (ETDEWEB)

    Rumleskie, Janet [Laurentian University, Greater Sudbury, Ontario (Canada)

    2015-12-31

    The SNO+ experiment will study neutrinos while located 6,800 feet below the surface of the earth at SNOLAB. Though shielded from surface backgrounds, emanation of radon radioisotopes from the surrounding rock leads to back-grounds. The characteristic decay of radon and its daughters allows for an alpha detection technique to count the amount of Rn-222 atoms collected. Traps can collect Rn-222 from various positions and materials, including an assay skid that will collect Rn-222 from the organic liquid scintillator used to detect interactions within SNO+.

  5. Prophylactic Antibiotics Use at IUCD Insertion and Pelvic Infection in ...

    African Journals Online (AJOL)

    The Mirena Intrauterine system was not used. The antibiotic used was oral Azithromycin. (Zithromax, Pfizer). In their Sexual history, the users did not report any change in sexual partners or habits after insertion of the device. They were followed up for three months after insertion. Results: Thirty-one clients were seen during ...

  6. Ultrasonic Guided Insertion of Central Venous Catheter in Infants ...

    African Journals Online (AJOL)

    Background/Purpose: ultrasound is licensed for application of regional blocks and insertion of vascular access. We aimed to compare ultrasonic guided (USG) and anatomical landmark technique (ALT) for insertion of central venous catheter (CVC) as regard success rate and rate of complications in infants and children.

  7. Lack of association of insertion/deletion polymorphism in ...

    African Journals Online (AJOL)

    In the present preliminary study the insertion/deletion polymorphism within angiotensin converting enzyme gene is not likely to be associated with nephropathy in type 2 diabetic patients of Punjabi population of Pakistan. Key words: Angiotensin converting enzymes, insertion/deletion polymorphism, albuminuria and type 2 ...

  8. Enhancement of heat transfer using varying width twisted tape inserts

    African Journals Online (AJOL)

    user

    width twisted tape inserts, ASME Transactions, Vol. 122, pp. 143-149. Naphon P., 2006. Heat transfer and pressure drop in the horizontal double pipes with and without twisted tape insert, International communications in Heat and Mass Transfer, Vol. 33, pp. 166-175. Promvonge P. and Eiamsa-ard S., 2007. Heat transfer ...

  9. Inactivation of a transgene due to transposition of insertion ...

    Indian Academy of Sciences (India)

    Agrobacterium strains harbour insertion sequences, which are known to transpose into genomes as well as into Ti plasmids. In this study we report the inactivation of a transgene due to transposition of the A. tumefaciens insertion sequence IS136. The transposition was discovered following transformation of plant tissues, ...

  10. Single-copy insertion of transgenes in Caenorhabditis elegans

    DEFF Research Database (Denmark)

    Frøkjaer-Jensen, Christian; Davis, M Wayne; Hopkins, Christopher E

    2008-01-01

    developed a method that inserts a single copy of a transgene into a defined site. Mobilization of a Mos1 transposon generates a double-strand break in noncoding DNA. The break is repaired by copying DNA from an extrachromosomal template into the chromosomal site. Homozygous single-copy insertions can...

  11. Packaging of airborne and spaceborne electronics

    Energy Technology Data Exchange (ETDEWEB)

    Pirzl, William H.

    1964-05-01

    The paper was prepared as a survey of problems associated with packaging of airborne and spaceborne electronics. Included is a discussion of the steps which must be taken in order to withstand applicable environmental conditions. Emphasis is placed on discussion of vibration, temperature control, radiation and electromagnetic compatibility of the packaged units.

  12. Development in the Active Packaging of Foods

    African Journals Online (AJOL)

    into, barrier packaging such as crown caps, plastic or metal closures, is ascorbate oxidation of flavour [13]} The Pillsbury Co. “hold a 1994 patent that also utilizes ..... superabsorbent polymer in between two layers. Large sheets are also used for absorption _of melted ice in package of seafood during air transportation. The.

  13. An expression analysis package for REDUCE

    NARCIS (Netherlands)

    van Hulzen, J.A.; Hulshof, B.J.A.

    1982-01-01

    An expression analysis package for REDUCE 2 is presented. This package, completely written in Standard LISP, can be considered as an extension of the algebraic mode. It allows to interactively dismantled and/or modify the last output expression as it is desplayed or printed. An interface with the

  14. A Thermodynamics Course Package in Onenote

    Science.gov (United States)

    Falconer, John L.; Nicodemus, Garret D.; Medlin, J. Will; deGrazia, Janet; McDanel, Katherine P.

    2014-01-01

    A ready-to-use package of active-learning materials for a semester-long chemical engineering thermodynamics course was prepared for instructors, and similar materials are being prepared for a material and energy balance course. The course package includes ConcepTests, explanations of the ConcepTests for instructors, links to screencasts, chapter…

  15. Wrap-Attack Pack: Product Packaging Exercise

    Science.gov (United States)

    Lee, Seung Hwan; Hoffman, K. Douglas

    2016-01-01

    Although many marketing courses discuss traditional concepts pertaining to product strategy, concepts specifically relating to packaging are often glossed over. This exercise, "Wrap-Attack Pack," teaches students about the utilitarian and hedonic design elements of packaging. More specifically, the primary objective is to creatively…

  16. The power of symbolic packaging cues

    NARCIS (Netherlands)

    van Ooijen, I.; Verlegh, P.; Voorveld, H.; Eisend, M.

    2016-01-01

    Packaging can be considered as an element of communication in the marketplace. By communicating through packaging, marketers are able to appeal to consumers at the most crucial moment in the consumer decision journey: the point of sale. At the point of sale, consumers are able to consider the

  17. 49 CFR 173.63 - Packaging exceptions.

    Science.gov (United States)

    2010-10-01

    ..., incendiary, or detonating explosive projectiles; (iv) Ammunition not exceeding 12.7 mm (50 caliber or 0.5... outside packagings; (iv) Maximum gross weight is limited to 30 kg (66 pounds) per package; and (v) Cartridges, power devices which are used to project fastening devices and 22 caliber rim-fire cartridges may...

  18. 21 CFR 820.130 - Device packaging.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Device packaging. 820.130 Section 820.130 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES... shall ensure that device packaging and shipping containers are designed and constructed to protect the...

  19. Packaging Materials Outgassing Study Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Smith, R. A. [Oak Ridge Y-12 Plant (Y-12), Oak Ridge, TN (United States)

    2006-09-26

    An outgassing study was conducted on two polyurethane packaging foams, two polymer bottles (polytetrafluoroethylene and polyethylene), and two polymer lids. The purpose was to measure the volume of gases that diffuse from these packaging materials at a maximum of 400-degrees F when stored in ambient air within sealed containers.

  20. Material Efficiency in Dutch Packaging Policy

    NARCIS (Netherlands)

    Worrell, E.|info:eu-repo/dai/nl/106856715; van Sluisveld, M.A.E.

    2013-01-01

    Packaging materials are one of the largest contributors to municipal solid waste generation. In this paper, we evaluate the material impacts of packaging policy in The Netherlands, focusing on the role of material efficiency (or waste prevention). Since 1991, five different policies have been

  1. Reliability of industrial packaging for microsystems

    DEFF Research Database (Denmark)

    Reus, Roger De; Christensen, Carsten; Weichel, Steen

    1998-01-01

    Packaging concepts for silicon-based micromachined sensors exposed to harsh environments are explored. By exposing the sensors directly to the media and applying protection at the wafer level the packaging and assembly will be simplified as compared to conventional methods of fabrication. Protect...

  2. Ceramic ball grid array package stress analysis

    Science.gov (United States)

    Badri, S. H. B. S.; Aziz, M. H. A.; Ong, N. R.; Sauli, Z.; Alcain, J. B.; Retnasamy, V.

    2017-09-01

    The ball grid array (BGA), a form of chip scale package (CSP), was developed as one of the most advanced surface mount devices, which may be assembled by an ordinary surface ball bumps are used instead of plated nickel and gold (Ni/Au) bumps. Assembly and reliability of the BGA's printed circuit board (PCB), which is soldered by conventional surface mount technology is considered in this study. The Ceramic Ball Grid Array (CBGA) is a rectangular ceramic package or square-shaped that will use the solder ball for external electrical connections instead of leads or wire for connections. The solder balls will be arranged in an array or grid at the bottom of the ceramic package body. In this study, ANSYS software is used to investigate the stress on the package for 2 balls and 4 balls of the CBGA package with the various force range of 1-3 Newton applied to the top of the die, top of the substrate and side of the substrate. The highest maximum stress was analyzed and the maximum equivalent stress was observed on the solder ball and the die. From the simulation result, the CBGA package with less solder balls experience higher stress compared to the package with many solder balls. Therefore, less number of solder ball on the CBGA package results higher stress and critically affect the reliability of the solder balls itself, substrate and die which can lead to the solder crack and also die crack.

  3. Effect of Modified Atmosphere Packaging on Microbiological ...

    African Journals Online (AJOL)

    Optimum packaging film for carrots should lead to low condensation, but preventing moisture loss, and maintain optimum gas composition during the storage period. In this study, carrots were packaged in polypropylene (PP) and low density polyethylene (LDPE) films and stored at 0¼C and ambient temperature (15-25¼C).

  4. 19 CFR 134.53 - Examination packages.

    Science.gov (United States)

    2010-04-01

    ... TREASURY COUNTRY OF ORIGIN MARKING Articles Found Not Legally Marked § 134.53 Examination packages. (a) Site of marking—(1) Customs custody. Articles (or containers) in examination packages may be marked by... the public stores. (2) Importer's premises or elsewhere. If it is impracticable to mark the articles...

  5. Pre-packaged applications in business reorganisations ...

    African Journals Online (AJOL)

    This study aims to explore the operating environment of pre-packaged financing in various established reorganisation regimes, including the legal framework, practice, enablers, context and other governing structures. Pre-packaging in the United States, United Kingdom, Australia and Canada was examined with a view to ...

  6. Clustering Classes in Packages for Program Comprehension

    Directory of Open Access Journals (Sweden)

    Xiaobing Sun

    2017-01-01

    Full Text Available During software maintenance and evolution, one of the important tasks faced by developers is to understand a system quickly and accurately. With the increasing size and complexity of an evolving system, program comprehension becomes an increasingly difficult activity. Given a target system for comprehension, developers may first focus on the package comprehension. The packages in the system are of different sizes. For small-sized packages in the system, developers can easily comprehend them. However, for large-sized packages, they are difficult to understand. In this article, we focus on understanding these large-sized packages and propose a novel program comprehension approach for large-sized packages, which utilizes the Latent Dirichlet Allocation (LDA model to cluster large-sized packages. Thus, these large-sized packages are separated as small-sized clusters, which are easier for developers to comprehend. Empirical studies on four real-world software projects demonstrate the effectiveness of our approach. The results show that the effectiveness of our approach is better than Latent Semantic Indexing- (LSI- and Probabilistic Latent Semantic Analysis- (PLSA- based clustering approaches. In addition, we find that the topic that labels each cluster is useful for program comprehension.

  7. Cigarette package design: opportunities for disease prevention

    Directory of Open Access Journals (Sweden)

    Pollay RW

    2003-01-01

    Full Text Available Abstract Objective To learn how cigarette packages are designed and to determine to what extent cigarette packages are designed to target children. Methods A computer search was made of all Internet websites that post tobacco industry documents using the search terms: packaging, package design, package study, box design, logo, trademark and design study. All documents were retrieved electronically and analyzed by the first author for recurrent themes. Data Synthesis Cigarette manufacturers devote a great deal of attention and expense to package design because it is central to their efforts to create brand images. Colors, graphic elements, proportioning, texture, materials and typography are tested and used in various combinations to create the desired product and user images. Designs help to create the perceived product attributes and project a personality image of the user with the intent of fulfilling the psychological needs of the targeted type of smoker. The communication of these images and attributes is conducted through conscious and subliminal processes. Extensive testing is conducted using a variety of qualitative and quantitative research techniques. Conclusion The promotion of tobacco products through appealing imagery cannot be stopped without regulating the package design. The same marketing research techniques used by the tobacco companies can be used to design generic packaging and more effective warning labels targeted at specific consumers.

  8. Life cycle assessment of EPS and CPB inserts: design considerations and end of life scenarios.

    Science.gov (United States)

    Tan, Reginald B H; Khoo, Hsien H

    2005-02-01

    Expanded polystyrene (EPS) and corrugated paperboard (CPB) are used in many industrial applications, such as containers, shock absorbers or simply as inserts. Both materials pose two different types of environmental problems. The first is the pollution and resource consumption that occur during the production of these materials; the second is the growing landfills that arise out of the excessive disposal of these packaging materials. Life cycle assessment or LCA will be introduced in this paper as a useful tool to compare the environmental performance of both EPS and CPB throughout their life cycle stages. This paper is divided into two main parts. The first part investigates the environmental impacts of the production of EPS and CPB from 'cradle-to-gate', comparing two inserts--both the original and proposed new designs. In the second part, LCA is applied to investigate various end-of-life cases for the same materials. The study will evaluate the environmental impacts of the present waste management practices in Singapore. Several 'what-if' cases are also discussed, including various percentages of landfilling and incineration. The SimaPro LCA Version 5.0 software's Eco-indicator 99 method is used to investigate the following five environmental impact categories: climate change, acidification/eutrophication, ecotoxicity, fossil fuels and respiratory inorganics.

  9. Analysis of the Sherlock II tip location system for inserting peripherally inserted central venous catheters.

    Science.gov (United States)

    Lelkes, Valdis; Kumar, Abhishek; Shukla, Pratik A; Contractor, Sohail; Rutan, Thomas

    2013-01-01

    Peripherally inserted central catheters (PICCs) are frequently placed at the bedside. The purpose of our study was to evaluate the efficacy of the Sherlock II tip location system (Bard Access Systems, Salt Lake City, UT), which offers electromagnetic detection of the PICC tip to assist the operator in guiding the tip to a desired location. We performed a retrospective review of patients who had a bedside PICC using the Sherlock II tip location system. Three hundred seventy-five of 384 patients (97.7%) had the catheter tip positioned appropriately. Our results suggest that the Sherlock II tip location system is an efficacious system for bedside PICC placement. Published by Elsevier Inc.

  10. Gas turbine nozzle vane insert and methods of installation

    Science.gov (United States)

    Miller, William John; Predmore, Daniel Ross; Placko, James Michael

    2002-01-01

    A pair of hollow elongated insert bodies are disposed in one or more of the nozzle vane cavities of a nozzle stage of a gas turbine. Each insert body has an outer wall portion with apertures for impingement-cooling of nozzle wall portions in registration with the outer wall portion. The insert bodies are installed into the cavity separately and spreaders flex the bodies toward and to engage standoffs against wall portions of the nozzle whereby the designed impingement gap between the outer wall portions of the insert bodies and the nozzle wall portions is achieved. The spreaders are secured to the inner wall portions of the insert bodies and the bodies are secured to one another and to the nozzle vane by welding or brazing.

  11. Central vascular catheter insertion in the NICU: a Lean approach.

    Science.gov (United States)

    Liu, Xinran; Suresh, Gautham

    2014-01-01

    To apply Lean principles to the process of inserting central lines into neonates in the NICU. The authors used standard interviews and live observations to obtain concrete data on the current process of central line insertions. Recommendations for improvement were then suggested based on Lean principles. NICU care providers. Non-value-added time (waste), provider confidence, and variation in placing central lines. There was large variation in how providers inserted central lines, and providers were least confident with placing peripherally inserted central catheter lines (55 percent confident). Live observations showed that 53 percent of the current process consisted of waste, with the line insertion and radiography phases of the process as the most wasteful. Lean principles can be applied to a neonatal clinical setting and can be an effective methodology for NICU care providers to improve the way that we care for our patients.

  12. Turbine airfoil having near-wall cooling insert

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Jr., Nicholas F.; Wiebe, David J.

    2017-09-12

    A turbine airfoil is provided with at least one insert positioned in a cavity in an airfoil interior. The insert extends along a span-wise extent of the turbine airfoil and includes first and second opposite faces. A first near-wall cooling channel is defined between the first face and a pressure sidewall of an airfoil outer wall. A second near-wall cooling channel is defined between the second face and a suction sidewall of the airfoil outer wall. The insert is configured to occupy an inactive volume in the airfoil interior so as to displace a coolant flow in the cavity toward the first and second near-wall cooling channels. A locating feature engages the insert with the outer wall for supporting the insert in position. The locating feature is configured to control flow of the coolant through the first or second near-wall cooling channel.

  13. PRIDE Surveillance Projects Data Packaging Project, Information Package Specification Version 1.0

    Energy Technology Data Exchange (ETDEWEB)

    Kelleher, D.M.; Shipp, R. L.; Mason, J. D.

    2009-09-28

    This document contains a specification for a standard XML document format called an information package that can be used to store information and the context required to understand and use that information in information management systems and other types of information archives. An information package consists of packaged information, a set of information metadata that describes the packaged information, and an XML signature that protects the packaged information. The information package described in this specification was designed to be used to store Department of Energy (DOE) and National Nuclear Security Administration (NNSA) information and includes the metadata required for that information: a unique package identifier, information marking that conforms to DOE and NNSA requirements, and access control metadata. Information package metadata can also include information search terms, package history, and notes. Packaged information can be text content, binary content, and the contents of files and other containers. A single information package can contain multiple types of information. All content not in a text form compatible with XML must be in a text encoding such as base64. Package information is protected by a digital XML signature that can be used to determine whether the information has changed since it was signed and to identify the source of the information. This specification has been tested but has not been used to create production information packages. The authors expect that gaps and unclear requirements in this specification will be identified as this specification is used to create information packages and as information stored in information packages is used. The authors expect to issue revised versions of this specification as needed to address these issues.

  14. Genotyping of the 19-bp insertion/deletion polymorphism in the 5' flank of beta-hydroxylase gene by dissociation analysis of allele-specific PCR products

    DEFF Research Database (Denmark)

    Rasmussen, Henrik Berg; Werge, Thomas

    2005-01-01

    and a conventional approach based upon agarose gel electrophoresis of amplified fragments revealed complete concordance between the two procedures. The insights obtained in this study may be utilized to develop assays based upon dissociation analysis of PCR products for genotyping of other insertion...

  15. Vacuum maintenance in hermetically sealed MEMs packages

    Science.gov (United States)

    Corazza, Alessio; Kullberg, Richard C.

    1998-09-01

    Packages for many high sensitivity MEM devices (Micro- Electro-Mechanical devices) such as accelerometers need to operate in a vacuum in order to obtain their full performance. This vacuum is destroyed by the outgassing of species such as hydrogen and water vapor from the surfaces of the package exposed to this vacuum. To control this outgassing a getter is needed. MEM packages are too small to accommodate traditional sintered porous getters. A solution has been developed using a high porosity thick film getter material. The getter consists of a highly porous, mechanically stable, getter coating on a metal substrate. This getter reacts with active gases such as water vapor, hydrogen, oxygen, nitrogen, and carbon monoxide that outgas from the inner surfaces of the package. The physical characteristics and performance of this material will be demonstrated per ASTM sorption testing. The results of this testing will be used to demonstrate the potential for vacuum performance in a real world MEM package.

  16. Service Packages – Attractiveness Has Many Faces

    Directory of Open Access Journals (Sweden)

    Ilona Bondos

    2016-01-01

    Full Text Available This article is an attempt to identify the impact of the customer age (especially the Baby boomers generation and the X and the Y generation on the assessment of incentives to buy service package. Belonging to different age generations seems to be important for the effectiveness of service packages sales – the entrance by the consumers in subsequent phases of the life cycle is related to their perception of the market offer. The starting point for the empirical part of the article was to analyze the different average scores attractiveness of the ten packages service features (incentives to purchase. Then, using multidimensional scaling authors determined the similarity or dissimilarity data on a set of applied incentives to use service packages. Visible differences indicate a different perception of the attractiveness of packages representatives of the Baby boomer generation and Y generation. Managerial implications and directions for future research are discussed.

  17. Dynamic modelling of packaging material flow systems.

    Science.gov (United States)

    Tsiliyannis, Christos A

    2005-04-01

    A dynamic model has been developed for reused and recycled packaging material flows. It allows a rigorous description of the flows and stocks during the transition to new targets imposed by legislation, product demand variations or even by variations in consumer discard behaviour. Given the annual reuse and recycle frequency and packaging lifetime, the model determines all packaging flows (e.g., consumption and reuse) and variables through which environmental policy is formulated, such as recycling, waste and reuse rates and it identifies the minimum number of variables to be surveyed for complete packaging flow monitoring. Simulation of the transition to the new flow conditions is given for flows of packaging materials in Greece, based on 1995--1998 field inventory and statistical data.

  18. Can packaging elements elicit consumers’ emotional responses?

    DEFF Research Database (Denmark)

    Liao, Lewis; Corsi, Armando; Lockshin, Larry

    Emotion has been an important concept in many areas of consumer research such as judgment, decision-making and advertising. Little research has been done on emotion in packaging adopting the physiological measures used in other areas. This paper draws on past studies in advertising that measure...... emotional responses toward image, colour and font, and apply them to packaging research. The study tests the extent at which packaging can elicit consumers’ spontaneous emotional response for each of those three elements, by using skin conductance, facial electromyography (EMG) and selfassessment scales....... The results show that packaging can elicit an emotional response via different elements. The paper also raises concerns about the accuracy of using selfreport measures of emotional responses to packaging research....

  19. Does 'Plain Packaging' of Tobacco matter?

    Directory of Open Access Journals (Sweden)

    Luke Clancy

    2016-03-01

    Full Text Available The incremental tightening of the tobacco industry’s advertising capabilities led to the investment of billions of dollars into increasingly creative packaging. Today, packing remains one of the industry’s sole methods of promotion and marketing. The size, shape, colour, and font on cigarette packs serve to differentiate brands and promote a certain image associated with the given cigarette package Many studies in recent years have tested the association between pack standardisation and peoples’ attitudes, behaviours, and perceptions of tobacco packaging. The results show that plain packs are thought to be less attractive and associated with less positive characteristics, the health warnings are more salient, and smokers report feelings of wanting to smoke less when using standardised packs. Now we have the real life results from Australia, which show the tobacco control advances that are possible with standardised packaging. This must increase the pressure to have 'plain packaging' introduced throughout the EU.

  20. Radiation treatment for sterilization of packaging materials

    Science.gov (United States)

    Haji-Saeid, Mohammad; Sampa, Maria Helena O.; Chmielewski, Andrzej G.

    2007-08-01

    Treatment with gamma and electron radiation is becoming a common process for the sterilization of packages, mostly made of natural or synthetic plastics, used in the aseptic processing of foods and pharmaceuticals. The effect of irradiation on these materials is crucial for packaging engineering to understand the effects of these new treatments. Packaging material may be irradiated either prior to or after filling. The irradiation prior to filling is usually chosen for dairy products, processed food, beverages, pharmaceutical, and medical device industries in the United States, Europe, and Canada. Radiation effects on packaging material properties still need further investigation. This paper summarizes the work done by different groups and discusses recent developments in regulations and testing procedures in the field of packaging technology.

  1. Optimization of Train Trip Package Operation Scheme

    Directory of Open Access Journals (Sweden)

    Lu Tong

    2015-01-01

    Full Text Available Train trip package transportation is an advanced form of railway freight transportation, realized by a specialized train which has fixed stations, fixed time, and fixed path. Train trip package transportation has lots of advantages, such as large volume, long distance, high speed, simple forms of organization, and high margin, so it has become the main way of railway freight transportation. This paper firstly analyzes the related factors of train trip package transportation from its organizational forms and characteristics. Then an optimization model for train trip package transportation is established to provide optimum operation schemes. The proposed model is solved by the genetic algorithm. At last, the paper tests the model on the basis of the data of 8 regions. The results show that the proposed method is feasible for solving operation scheme issues of train trip package.

  2. 76 FR 51257 - First-Class Package Service

    Science.gov (United States)

    2011-08-18

    ... Package Service, Periodicals, and Package Services pieces addressed to a discontinued Post Office may be... have all Express Mail, Priority Mail, First-Class Mail, First-Class Package Service, Periodicals, and... Personnel All Express Mail, First-Class Mail, First-Class Package Service, Periodicals, and Package Services...

  3. IFT Scientific Status Summary 2008: Innovative Food Packaging Solutions

    Science.gov (United States)

    Food and beverage packaging comprises 55-65% of the $110 billion value of packaging in the United States. This review provides a summary of innovative technology developments in food packaging. The expanded role of food and beverage packaging is reviewed. Active and intelligent food packaging, ba...

  4. Directory of certificates of compliance for radioactive materials packages. Summary report of NRC approved packages

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-10-01

    This directory contains a Summary Report of NRC Approved Packages for radioactive material packages effective September 14, 1979. Purpose of this directory is to make available a convenient source of information on packagings which have been approved by the US Nuclear Regulatory Commission. To assist in identifying packaging, an index by Model Number and corresponding Certificate of Compliance number is included at the back of each volume of the directory. The Summary Report includes a listing of all users of each package design prior to the publication date of the directory.

  5. Interconnect mechanisms in microelectronic packaging

    Science.gov (United States)

    Roma, Maria Penafrancia C.

    alloy showed differences in adhesion strength and IMC formation. Bond strength by wire pull testing showed the 95Ag alloy with higher values while shear bond testing showed the 88Ag higher bond strength. Use of Cu pillars in flip chips and eutectic bonding in wafer level chip scale packages are direct consequences of diminishing interconnect dimension as a result of the drive for miniaturization. The combination of Cu-Sn interdiffusion, Kirkendall mechanism and heterogeneous vacancy precipitation are the main causes of IMC and void formation in Cu pillar - Sn solder - Cu lead frame sandwich structure. However, adding a Ni barrier agent showed less porous IMC layer as well as void formation as a result of the modified Cu and Sn movement well as the void formation. Direct die to die bonding using Al-Ge eutectic bonds is necessary when 3D integration is needed to reduce the footprint of a package. Hermeticity and adhesion strength are a function of the Al/Ge thickness ratio, bonding pressure, temperature and time. Scanning Electron Microscope (SEM) and Focused Ion Beam (FIB) allowed imaging of interfacial microstructures, porosity, grain morphology while Scanning Transmission Electron microscope (STEM) provided diffusion profile and confirmed interdiffusion. Ion polishing technique provided information on porosity and when imaged using backscattered mode, grain structure confirmed mechanical deformation of the bonds. Measurements of the interfacial bond strength are made by wire pull tests and ball shear tests based on existing industry standard tests. However, for the Al-Ge eutectic bonds, no standard strength is available so a test is developed using the stud pull test method using the Dage 4000 Plus to yield consistent results. Adhesion strengths of 30-40 MPa are found for eutectic bonded packages however, as low as 20MPa was measured in low temperature bonded areas.

  6. Peripherally-inserted Central Catheter (PICC Insertion in Neonates: Apnea and Radiocontrasts Complications

    Directory of Open Access Journals (Sweden)

    Eissa Bilehjani

    2015-01-01

    Full Text Available The importance of pain management throughout minimally-invasive procedures such as peripherally-inserted central catheter (PICC insertion is an inevitable fact. However, administration of varied analgesics, especially opioids, in specific age ranges such as neonate could be of immense concern. Most of these patients are on different medications, especially those hospitalized in the ICUs or with critical conditions. Neonates receiving continuous opioid infusions might also require an additional opioid bolus to control the associated pain (1. Importantly, it should be taken into consideration that administration of opioids or even a light sedation would increase the risk of delayed apnea in this group of patients (2. Factors contributing to this complication include ex-premature infants (gestational age<37 weeks, premature infants younger than 46 weeks’ postconceptual age and anemia (hematocrit< 30% (3, 4. Hence, it is recommended to use other supplementary analgesic techniques including local or topical anesthesia, especially in neonates having previously received continuous or bolus opioids. Furthermore, supplementary techniques assisting the confirmation of proper placement such as overpenetrating the radiograph, lateral X-rays and positioning the infant for a lateral oblique radiograph (right side elevated at a 10°–15° angle are frequently used by clinicians to avoid administration of radiocontrasts and their associated complications. In the latter technique, catheter visualization could be enhanced as the PICC will not be superimposed over the mediastinal structures (5, 6.

  7. Compostability of bioplastic packaging materials: an overview.

    Science.gov (United States)

    Kale, Gaurav; Kijchavengkul, Thitisilp; Auras, Rafael; Rubino, Maria; Selke, Susan E; Singh, Sher Paul

    2007-03-08

    Packaging waste accounted for 78.81 million tons or 31.6% of the total municipal solid waste (MSW) in 2003 in the USA, 56.3 million tons or 25% of the MSW in 2005 in Europe, and 3.3 million tons or 10% of the MSW in 2004 in Australia. Currently, in the USA the dominant method of packaging waste disposal is landfill, followed by recycling, incineration, and composting. Since landfill occupies valuable space and results in the generation of greenhouse gases and contaminants, recovery methods such as reuse, recycling and/or composting are encouraged as a way of reducing packaging waste disposal. Most of the common materials used in packaging (i.e., steel, aluminum, glass, paper, paperboard, plastics, and wood) can be efficiently recovered by recycling; however, if packaging materials are soiled with foods or other biological substances, physical recycling of these materials may be impractical. Therefore, composting some of these packaging materials is a promising way to reduce MSW. As biopolymers are developed and increasingly used in applications such as food, pharmaceutical, and consumer goods packaging, composting could become one of the prevailing methods for disposal of packaging waste provided that industry, governments, and consumers encourage and embrace this alternative. The main objective of this article is to provide an overview of the current situation of packaging compostability, to describe the main mechanisms that make a biopolymer compostable, to delineate the main methods to compost these biomaterials, and to explain the main standards for assessing compostability, and the current status of biopolymer labeling. Biopolymers such as polylactide and poly(hydroxybutyrate) are increasingly becoming available for use in food, medical, and consumer goods packaging applications. The main claims of these new biomaterials are that they are obtained from renewable resources and that they can be biodegraded in biological environments such as soil and compost

  8. MEMS Direct Chip Attach Packaging Methodologies and Apparatuses for Harsh Environments

    Science.gov (United States)

    Okojie, Robert S. (Inventor)

    2009-01-01

    Methods of bulk manufacturing high temperature sensor subassembly packages are disclosed and claimed. Sensors are sandwiched between a top cover and a bottom cover so as to enable the peripheries of the top covers, sensors and bottom covers to be sealed and bound securely together are disclosed and claimed. Sensors are placed on the bottom covers leaving the periphery of the bottom cover exposed. Likewise, top covers are placed on the sensors leaving the periphery of the sensor exposed. Individual sensor sub-assemblies are inserted into final packaging elements which are also disclosed and claimed. Methods of directly attaching wires or pins to contact pads on the sensors are disclosed and claimed. Sensors, such as pressure sensors and accelerometers, and headers made out of silicon carbide and aluminum nitride are disclosed and claimed. Reference cavities are formed in some embodiments disclosed and claimed herein where top covers are not employed.

  9. FLUIDICS DEVICE FOR ASSAY

    DEFF Research Database (Denmark)

    2007-01-01

    The present invention relates to a device for use in performing assays on standard laboratory solid supports whereon chemical entities are attached. The invention furthermore relates to the use of such a device and a kit comprising such a device. The device according to the present invention...... is adapted to receive one or more replaceable solid support(s) (40) onto which chemical entities (41) are attached, said device comprising a base (1, 60, 80, 300, 400, 10, 70, 140, 20, 90, 120, 150, 30, 100), one or more inlet(s) (5), one or more outlet(s) (6). The base and the solid support (40) defines......, when operatively connected, one or more chambers (21) comprising the chemical entities (41), the inlet(s) (5) and outlet(s) (6) and chambers (21) being in fluid connection. The device further comprise means for providing differing chemical conditions in each chamber (21)....

  10. PORTABLE ACOUSTIC MONITORING PACKAGE (PAMP)

    Energy Technology Data Exchange (ETDEWEB)

    John L. Loth; Gary J. Morris; George M. Palmer; Richard Guiler; Patrick Browning

    2004-07-20

    The Portable Acoustic Monitoring Package (PAMP) has been designed to record and monitor the acoustic signal in natural gas transmission lines. In particular the three acoustic signals associated with a line leak. The system is portable ({approx}30 lbs) and is designed for line pressures up to 1000 psi. It has become apparent that cataloging of the various background acoustic signals in natural gas transmission line is very important if a system to identify leak signals is to be developed. The low-pressure (0-200 psig) laboratory test phase has been completed and a number of field trials have been conducted. Before the cataloging phase could begin, a few problems identified in field trials identified had to be corrected such as: (1) Decreased microphone sensitivity at line pressures above 250 psig. (2) The inability to deal with large data sets collected when cataloging the variety of signals in a transmission line. (3) The lack of an available online acoustic calibration system. These problems have been solved and the WVU PAMP is now fully functional over the entire pressure range found in the Natural Gas transmission lines in this region. Field portability and reliability have been greatly improved. Data collection and storage have also improved to the point were the full acoustic spectrum of acoustic signals can be accurately cataloged, recorded and described.

  11. The Fireball integrated code package

    Energy Technology Data Exchange (ETDEWEB)

    Dobranich, D.; Powers, D.A.; Harper, F.T.

    1997-07-01

    Many deep-space satellites contain a plutonium heat source. An explosion, during launch, of a rocket carrying such a satellite offers the potential for the release of some of the plutonium. The fireball following such an explosion exposes any released plutonium to a high-temperature chemically-reactive environment. Vaporization, condensation, and agglomeration processes can alter the distribution of plutonium-bearing particles. The Fireball code package simulates the integrated response of the physical and chemical processes occurring in a fireball and the effect these processes have on the plutonium-bearing particle distribution. This integrated treatment of multiple phenomena represents a significant improvement in the state of the art for fireball simulations. Preliminary simulations of launch-second scenarios indicate: (1) most plutonium vaporization occurs within the first second of the fireball; (2) large non-aerosol-sized particles contribute very little to plutonium vapor production; (3) vaporization and both homogeneous and heterogeneous condensation occur simultaneously; (4) homogeneous condensation transports plutonium down to the smallest-particle sizes; (5) heterogeneous condensation precludes homogeneous condensation if sufficient condensation sites are available; and (6) agglomeration produces larger-sized particles but slows rapidly as the fireball grows.

  12. Gene-scrambling mutagenesis: generation and analysis of insertional mutations in the alginate regulatory region of Pseudomonas aeruginosa.

    Science.gov (United States)

    Mohr, C D; Deretic, V

    1990-11-01

    A novel method for random mutagenesis of targeted chromosomal regions in Pseudomona aeruginosa was developed. This method can be used with a cloned DNA fragment of indefinite size that contains a putative gene of interest. Cloned DNA is digested to produce small fragments that are then randomly reassembled into long DNA inserts by using cosmid vectors and lambda packaging reaction. This DNA is then transferred into P. aeruginosa and forced into the chromosome via homologous recombination, producing in a single step a random set of insertional mutants along a desired region of the chromosome. Application of this method to extend the analysis of the alginate regulatory region, using a cloned 6.2-kb fragment with the algR gene and the previously uncharacterized flanking regions, produced several insertional mutations. One mutation was obtained in algR, a known transcriptional regulatory of mucoidy in P. aeruginosa. The null mutation of algR was generated in a mucoid derivative of the standard genetic strain PAO responsive to different environmental factors. This mutation was used to demonstrate that the algR gene product was not essential for the regulation of its promoters. Additional insertions were obtained in regions downstream and upstream of algR. A mutation that did not affect mucoidy was generated in a gene located 1 kb upstream of algR. This gene was transcribed in the direction opposite that of algR transcription and encoded a polypeptide of 47 kDa. Partial nucleotide sequence analysis revealed strong homology of its predicted gene product with the human and yeast argininosuccinate lyases. An insertion downstream of algR produced a strain showing reduced induction of mucoidy in response to growth on nitrate as the nitrogen source.

  13. Survival assays using Caenorhabditis elegans.

    Science.gov (United States)

    Park, Hae-Eun H; Jung, Yoonji; Lee, Seung-Jae V

    2017-02-01

    Caenorhabditis elegans is an important model organism with many useful features, including rapid development and aging, easy cultivation, and genetic tractability. Survival assays using C. elegans are powerful methods for studying physiological processes. In this review, we describe diverse types of C. elegans survival assays and discuss the aims, uses, and advantages of specific assays. C. elegans survival assays have played key roles in identifying novel genetic factors that regulate many aspects of animal physiology, such as aging and lifespan, stress response, and immunity against pathogens. Because many genetic factors discovered using C. elegans are evolutionarily conserved, survival assays can provide insights into mechanisms underlying physiological processes in mammals, including humans.

  14. Method of joining a vane cavity insert to a nozzle segment of a gas turbine

    Science.gov (United States)

    Burdgick, Steven Sebastian

    2002-01-01

    An insert containing apertures for impingement cooling a nozzle vane of a nozzle segment in a gas turbine is inserted into one end of the vane. The leading end of the insert is positioned slightly past a rib adjacent the opposite end of the vane through which the insert is inserted. The end of the insert is formed or swaged into conformance with the inner margin of the rib. The insert is then brazed or welded to the rib.

  15. Emission Characteristics of Amorphous Silicon Field Emitter Arrays Sealed in a Vacuum Package

    Science.gov (United States)

    Gamo, Hidenori; Kai, Teruhiko; Kanemaru, Seigo; Itoh, Junji

    1999-12-01

    Emission characteristics of amorphous silicon field emitter arrays (a-Si FEAs) in a vacuum package sealed with TO-5 have been measured and evaluated. The TO-5 header mounted with a FEA, was inserted through a hole in a glass plate and was hermetically sealed to the glass plate using epoxy resin as a sealant. In the same a-Si FEA device, lower emission currents have been observed in the vacuum package, as compared with those measured in an ultra-high vacuum (UHV) chamber. On the other hand, an a-Si FEA monolithically integrated with a thin-film transistor (TFT) has exhibited almost the same emission characteristics both in the vacuum package and in the UHV chamber at the region of saturated emission currents due to the TFT function. A highly stable emission current of approximately 0.1 µA and with fluctuations of less than 2% has been achieved in the vacuum package at the TFT gate and the extraction voltages of 14 V and 150 V, respectively.

  16. Extreme temperature packaging: challenges and opportunities

    Science.gov (United States)

    Johnson, R. Wayne

    2016-05-01

    Consumer electronics account for the majority of electronics manufactured today. Given the temperature limits of humans, consumer electronics are typically rated for operation from -40°C to +85°C. Military applications extend the range to -65°C to +125°C while underhood automotive electronics may see +150°C. With the proliferation of the Internet of Things (IoT), the goal of instrumenting (sensing, computation, transmission) to improve safety and performance in high temperature environments such as geothermal wells, nuclear reactors, combustion chambers, industrial processes, etc. requires sensors, electronics and packaging compatible with these environments. Advances in wide bandgap semiconductors (SiC and GaN) allow the fabrication of high temperature compatible sensors and electronics. Integration and packaging of these devices is required for implementation into actual applications. The basic elements of packaging are die attach, electrical interconnection and the package or housing. Consumer electronics typically use conductive adhesives or low melting point solders for die attach, wire bonds or low melting solder for electrical interconnection and epoxy for the package. These materials melt or decompose in high temperature environments. This paper examines materials and processes for high temperature packaging including liquid transient phase and sintered nanoparticle die attach, high melting point wires for wire bonding and metal and ceramic packages. The limitations of currently available solutions will also be discussed.

  17. APPLICATION OF NANOTECHNOLOGY IN FOOD PACKAGING

    Directory of Open Access Journals (Sweden)

    Renata Dobrucka

    2014-04-01

    Full Text Available Nanotechnology involves the design, production and use of structures through control of the size and shape of the materials at the nanometre scale. Also, nanomaterials have been already applied in many fields of human life. Nanocomposites have already led to several innovations with potential applications in the food packaging sector. The use of nanocomposite formulations is expected to considerably enhance the shelf-life of many types of food. This improvement can lead to lower weight packages because less material is needed to obtain the same or even better barrier properties. This, in turn, can lead to reduced package cost with less packaging waste. Antimicrobial packaging is another area with high potential for applying nanocomposite technology. Nanostructured antimicrobials have a higher surface area-to-volume ratio when compared with their higher scale counterparts. Therefore, antimicrobial nanocomposite packaging systems are supposed to be particularly efficient in their activities against microbial cells. In this review, definition of nanomaterials is presented. Besides, the paper shows examples of nanocomposities and antimicrobial nanopackaging mainly with the use of nanosilver. Moreover, nanoparticles such ZnO, TiO2, MgO and nanosensors in packaging were presented.

  18. Cell Proliferation and Cytotoxicity Assays.

    Science.gov (United States)

    Adan, Aysun; Kiraz, Yağmur; Baran, Yusuf

    Cell viability is defined as the number of healthy cells in a sample and proliferation of cells is a vital indicator for understanding the mechanisms in action of certain genes, proteins and pathways involved cell survival or death after exposing to toxic agents. Generally, methods used to determine viability are also common for the detection of cell proliferation. Cell cytotoxicity and proliferation assays are generally used for drug screening to detect whether the test molecules have effects on cell proliferation or display direct cytotoxic effects. Regardless of the type of cell-based assay being used, it is important to know how many viable cells are remaining at the end of the experiment. There are a variety of assay methods based on various cell functions such as enzyme activity, cell membrane permeability, cell adherence, ATP production, co-enzyme production, and nucleotide uptake activity. These methods could be basically classified into different categories: (I) dye exclusion methods such as trypan blue dye exclusion assay, (II) methods based on metabolic activity, (III) ATP assay, (IV) sulforhodamine B assay, (V) protease viability marker assay, (VI) clonogenic cell survival assay, (VII) DNA synthesis cell proliferation assays and (V) raman micro-spectroscopy. In order to choose the optimal viability assay, the cell type, applied culture conditions, and the specific questions being asked should be considered in detail. This particular review aims to provide an overview of common cell proliferation and cytotoxicity assays together with their own advantages and disadvantages, their methodologies, comparisons and intended purposes.

  19. Intracochlear Pressure Transients During Cochlear Implant Electrode Insertion.

    Science.gov (United States)

    Greene, Nathaniel T; Mattingly, Jameson K; Banakis Hartl, Renee M; Tollin, Daniel J; Cass, Stephen P

    2016-12-01

    Cochlear implant (CI) electrode insertion into the round window induces pressure transients in the cochlear fluid comparable to high-intensity sound transients. Many patients receiving a CI have some remaining functional hearing at low frequencies; thus, devices and surgical techniques have been developed to use this residual hearing. To maintain functional acoustic hearing, it is important to retain function of any hair cells and auditory nerve fibers innervating the basilar membrane; however, in a subset of patients, residual low-frequency hearing is lost after CI insertion. Here, we test the hypothesis that transient intracochlear pressure spikes are generated during CI electrode insertion, which could cause damage and compromise residual hearing. Human cadaveric temporal bones were prepared with an extended facial recess. Pressures in the scala vestibuli and tympani were measured with fiber-optic pressure sensors inserted into the cochlea near the oval and round windows, whereas CI electrodes (five styles from two manufacturers) were inserted into the cochlea via a round window approach. Pressures in the scala tympani tended to be larger in magnitude than pressures in the scala vestibuli, consistent with electrode insertion into the scala tympani. CI electrode insertion produced a range of pressure transients in the cochlea that could occur alone or as part of a train of spikes with equivalent peak sound pressure levels in excess of 170 dB sound pressure level. Instances of pressure transients varied with electrode styles. Results suggest electrode design, insertion mechanism, and surgical technique affect the magnitude and rate of intracochlear pressure transients during CI electrode insertion. Pressure transients showed intensities similar to those elicited by high-level sounds and thus could cause damage to the basilar membrane and/or hair cells.

  20. Redefining Zone II: Anatomy of the Flexor Digitorum Superficialis Insertion.

    Science.gov (United States)

    Nicholson, Luke T; Hill, Jeffrey R; McKnight, Braden; Heckmann, Nathanael; Stevanovic, Milan; Ghiassi, Alidad

    2017-10-01

    Flexor zone II is defined as the region spanning the proximal aspect of the A1 pulley to the insertion of the flexor digitorum superficialis (FDS) tendon. Descriptions of the FDS insertion are inconsistent in the literature, but zones of injury are frequently determined with reference to superficial landmarks. The purpose of this study was to describe the footprint of the FDS insertion and define its relationship to the proximal interphalangeal (PIP) skin crease. The FDS insertion on the index, middle, ring, and small fingers was dissected in 6 matched pairs of fresh-frozen cadaveric hands. A Kirschner wire was used to mark the level of the PIP skin crease on bone before measurements of the FDS footprint and its position relative to the PIP skin crease were made using digital calipers. The radial and ulnar FDS slips inserted a mean distance of 3.22 mm from the distal aspect of the PIP skin crease and varied by digit. The mean distal extent of the FDS insertion was 8.29 mm. The mean length of the insertion of each FDS slip was 5.15 mm and the mean width was 1.9 mm. The radial and ulnar FDS slips insert on average 3.22 mm distal to the PIP skin crease and vary by digit. Knowledge of the FDS insertion is clinically relevant when differentiating between flexor zone I and zone II injuries, planning surgical approaches to the finger, and in guiding patient expectations for surgery given the variability in outcome based on zone of injury.

  1. Food packaging and shelf life: a practical guide

    National Research Council Canada - National Science Library

    Robertson, Gordon L

    2010-01-01

    .... Food Packaging and Shelf Life: A Practical Guide provides package developers with the information they need to specify just the right amount of protective packaging to maintain food quality and maximize shelf life...

  2. An Assessment of the Influence of the Industry Distribution Chain on the Oxygen Levels in Commercial Modified Atmosphere Packaged Cheddar Cheese Using Non-Destructive Oxygen Sensor Technology.

    Science.gov (United States)

    O' Callaghan, Karen A M; Papkovsky, Dmitri B; Kerry, Joseph P

    2016-06-20

    The establishment and control of oxygen levels in packs of oxygen-sensitive food products such as cheese is imperative in order to maintain product quality over a determined shelf life. Oxygen sensors quantify oxygen concentrations within packaging using a reversible optical measurement process, and this non-destructive nature ensures the entire supply chain can be monitored and can assist in pinpointing negative issues pertaining to product packaging. This study was carried out in a commercial cheese packaging plant and involved the insertion of 768 sensors into 384 flow-wrapped cheese packs (two sensors per pack) that were flushed with 100% carbon dioxide prior to sealing. The cheese blocks were randomly assigned to two different storage groups to assess the effects of package quality, packaging process efficiency, and handling and distribution on package containment. Results demonstrated that oxygen levels increased in both experimental groups examined over the 30-day assessment period. The group subjected to a simulated industrial distribution route and handling procedures of commercial retailed cheese exhibited the highest level of oxygen detected on every day examined and experienced the highest rate of package failure. The study concluded that fluctuating storage conditions, product movement associated with distribution activities, and the possible presence of cheese-derived contaminants such as calcium lactate crystals were chief contributors to package failure.

  3. Industrial stator vane with sequential impingement cooling inserts

    Science.gov (United States)

    Jones, Russell B; Fedock, John A; Goebel, Gloria E; Krueger, Judson J; Rawlings, Christopher K; Memmen, Robert L

    2013-08-06

    A turbine stator vane for an industrial engine, the vane having two impingement cooling inserts that produce a series of impingement cooling from the pressure side to the suction side of the vane walls. Each insert includes a spar with a row of alternating impingement cooling channels and return air channels extending in a radial direction. Impingement cooling plates cover the two sides of the insert and having rows of impingement cooling holes aligned with the impingement cooling channels and return air openings aligned with the return air channel.

  4. Flat conductor cable for electrical packaging

    Science.gov (United States)

    Angele, W.

    1972-01-01

    Flat conductor cable (FCC) is relatively new, highly promising means for electrical packaging and system integration. FCC offers numerous desirable traits (weight, volume and cost savings, flexibility, high reliability, predictable and repeatable electrical characteristics) which make it extremely attractive as a packaging medium. FCC, today, finds wide application in everything from integration of lunar equipment to the packaging of electronics in nuclear submarines. Described are cable construction and means of termination, applicable specifications and standards, and total FCC systems. A list of additional sources of data is also included for more intensive study.

  5. Void-Free Lid for Food Packaging

    Science.gov (United States)

    Watson, C. D.; Farris, W. P.

    1986-01-01

    Flexible cover eliminates air pockets in sealed container. Universal food-package lid formed from flexible plastic. Partially folded, lid unfolded by depressing center portion. Height of flat portion of lid above flange thereby reduced. Pressure of food against central oval depression pops it out, forming dome that provides finger grip for mixing contents with water or opening lid. Therefore food stays fresh, allows compact stacking of partially filled containers, and resists crushing. Originally developed for packaging dehydrated food for use in human consumption on Space Shuttle missions. Other uses include home canning and commercial food packaging.

  6. The art of packaging: An investigation into the role of color in packaging, marketing, and branding

    Directory of Open Access Journals (Sweden)

    Behzad Mohebbi

    2014-12-01

    Full Text Available The purpose of this study is to contribute to the existing research in the field of packaging and marketing and shed more light on the psychology of colors and their effect on packaging and marketing. Nowadays, packaging is proved to be one of the significant factors in the success of promoting product sale. However, there is a perceived gap with respect to the different aspects of packaging, in particular the graphics, design, and color of packaging. The current study provides a comprehensive overview of packaging. It elaborates on different aspects of packaging and summarizes the findings of the most recent research conducted to date probing into packaging from different perspectives. It also discusses the role of color, i.e., the psychology of colors, and graphics in packaging and product sale. It is argued that graphics and color play key roles in promoting product sale and designers and marketers should attach a great deal of importance to color in packaging. The implications for producers, marketers, practitioners, and researchers are discussed in detail and suggestions for future research are provided.

  7. RECENT TRENDS IN PACKAGING SYSTEMS FOR PHARMACEUTICAL PRODUCTS

    Directory of Open Access Journals (Sweden)

    Renata Dobrucka

    2014-12-01

    Full Text Available Background:  In recent years, pharmaceutical packaging market was one of the fastest growing areas of the packaging industry. At the same time the packaging manufacturers put high demands on quality and safety. Methods: Review of innovations in packaging systems for pharmaceutical products was made including newest information of researches and achievements of recent years. Results and conclusion: Observed in recent years the development of pharmaceutical packaging market expanded due to with the huge technological advances that allow introduction of new packaging. Also, in this study presented intelligent packaging in pharmacy and innovation in child-resistance packaging.

  8. The accuracy and the safety of individualized 3D printing screws insertion templates for cervical screw insertion.

    Science.gov (United States)

    Deng, Ting; Jiang, Minghui; Lei, Qing; Cai, Lihong; Chen, Li

    2016-12-01

    Clinical trial for cervical screw insertion by using individualized 3-dimensional (3D) printing screw insertion templates device. The objective of this study is to evaluate the safety and accuracy of the individualized 3D printing screw insertion template in the cervical spine. Ten patients who underwent posterior cervical fusion surgery with cervical pedicle screws, laminar screws or lateral mass screws between December 2014 and December 2015 were involved in this study. The patients were examined by CT scan before operation. The individualized 3D printing templates were made with photosensitive resin by a 3D printing system to ensure the screw shafts entered the vertebral body without breaking the pedicle or lamina cortex. The templates were sterilized by a plasma sterilizer and used during the operation. The accuracy and the safety of the templates were evaluated by CT scans at the screw insertion levels after operation. The accuracy of this patient-specific template technique was demonstrated. Only one screw axis greatly deviated from the planned track and breached the cortex of the pedicle because the template was split by rough handling and then we inserted the screws under the fluoroscopy. The remaining screws were inserted in the track as preoperative design and the screw axis deviated by less than 2 mm. Vascular or neurologic complications or injuries did not happen. And no infection, broken nails, fracture of bone structure, or screw pullout occurred. This study verified the safety and the accuracy of the individualized 3D printing screw insertion templates in the cervical spine as a kind of intraoperative screw navigation. This individualized 3D printing screw insertion template was user-friendly, moderate cost, and enabled a radiation-free cervical screw insertion.

  9. Assay for calcium channels

    Energy Technology Data Exchange (ETDEWEB)

    Glossmann, H.; Ferry, D.R.

    1985-01-01

    This chapter focuses on biochemical assays for Ca/sup 2 +/-selective channels in electrically excitable membranes which are blocked in electrophysiological and pharmacological experiments by verapamil, 1,4-dihydropyridines, diltiazen (and various other drugs), as well as inorganic di- or trivalent cations. The strategy employed is to use radiolabeled 1,4-dihydropyridine derivatives which block calcium channels with ED/sub 50/ values in the nanomolar range. Although tritiated d-cis-diltiazem and verapamil can be used to label calcium channels, the 1,4-dihydropyridines offer numerous advantages. The various sections cover tissue specificity of channel labeling, the complex interactions of divalent cations with the (/sup 3/H)nimodipine-labeled calcium channels, and the allosteric regulation of (/sup 3/H)nimodipine binding by the optically pure enantiomers of phenylalkylamine and benzothiazepine calcium channel blockers. A comparison of the properties of different tritiated 1,4-dihydropyridine radioligands and the iodinated channel probe (/sup 125/I)iodipine is given.

  10. Inserts and omissions in the Calvinist Catechism printed in 1648

    National Research Council Canada - National Science Library

    Pál, Enikő

    2015-01-01

    .... In this respect, the pursued objective is to set up a typology of inserts and omissions found in the Romanian translation of the catechism printed in 1648, taking into account the main causes which generated...

  11. The use of dimorphic Alu insertions in human DNA fingerprinting

    Energy Technology Data Exchange (ETDEWEB)

    Novick, G.E.; Gonzalez, T.; Garrison, J.; Novick, C.C.; Herrera, R.J. [Florida International Univ., Miami, FL (United States). Dept. of Biological Sciences; Batzer, M.A. [Lawrence Livermore National Lab., CA (United States); Deininger, P.L. [Louisiana State Univ., New Orleans, LA (United States). Medical Center

    1992-12-04

    We have characterized certain Human Specific Alu Insertions as either dimorphic (TPA25, PV92, APO), sightly dimorphic (C2N4 and C4N4) or monomorphic (C3N1, C4N6, C4N2, C4N5, C4N8), based on studies of Caucasian, Asian, American Black and African Black populations. Our approach is based upon: (1) PCR amplification using primers directed to the sequences that flank the site of insertion of the different Alu elements studied; (2) gel electrophoresis and scoring according to the presence or absence of an Alu insertion in one or both homologous chromosomes; (3) allelic frequencies calculated and compared according to Hardy-Weinberg equilibrium. Our DNA fingerprinting procedure using PCR amplification of dimorphic Human Specific Alu insertions, is stable enough to be used not only as a tool for genetic mapping but also to characterize populations, study migrational patterns and track the inheritance of human genetic disorders.

  12. On the Phenomenon of Inserted Thoughts: A Critique of Shaun ...

    African Journals Online (AJOL)

    It is argued here that our sense of agency for thinking requires more than protention, and, ... fully explain the loss of agency for thinking characterizing the experience of thought insertion. ... EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT

  13. Laparoscopic insertion of lumbar peritoneal shunts for idiopathic ...

    African Journals Online (AJOL)

    Background: The treatment of idiopathic intracranial hypertension varies from simple observation to the mechanical diversion of cerebrospinal fluid. Objective: To describe our technique and initial experience with the laparoscopic insertion of lumbarperitoneal shunts. Conclusion: Lumbarperitoneal shunts should be ...

  14. Fireplace insert and its parameters depend on the used glazing

    Science.gov (United States)

    Papučík, Štefan; Čaja, Alexander

    2016-06-01

    The contribution deals with the analysis of the impact of using double glass to change the performance and emission parameters of the fireplace insert. Conventional fireplace inserts are equipped with heat-resistant glass, which is resistant to high temperatures. For this type of inserts are required to be radiant constituent maximized. Prevailing part of heat is into the interior gets just by radiation through the glazed part. The hot water fireplace inserts is the requirement that the radiant constituent to the environment to a minimum. Therefore, instead of a single glass using double glazing which is intended to reduce this part of heat transfer. The temperature in the furnace is increased, and transmitted most of the heat into the water.

  15. Green packaging from a company’s perspective: Determining factors for packaging solutions in the German fruit juice industry

    OpenAIRE

    Ramme, Iris; Heimann, Ruth

    2015-01-01

    In Germany, extensive legislation aims at getting companies to engage in eco-friendly packaging. A common packaging challenge centers on fruit juice products the packaging of which ranges from carton container, to glass or plastic bottles. This study examined the prevalence of Green Packaging in the Baden-Württemberg fruit juice industry. Expert interviews reveal that these companies make packaging decisions based on bottling volume and financial resources and not on Green Packaging concerns....

  16. Shoe inserts and orthotics for sport and physical activities.

    Science.gov (United States)

    Nigg, B M; Nurse, M A; Stefanyshyn, D J

    1999-07-01

    The purposes of this paper were to discuss the perceived benefits of inserts and orthotics for sport activities and to propose a new concept for inserts and orthotics. There is evidence that inserts or orthotics reduce or prevent movement-related injuries. However, there is limited knowledge about the specific functioning an orthotic or insert provides. The same orthotic or insert is often proposed for different problems. Changes in skeletal movement due to inserts or orthotics seem to be small and not systematic. Based on the results of a study using bone pins, one may question the idea that a major function of orthotics or inserts consists in aligning the skeleton. Impact cushioning with shoe inserts or orthotics is typically below 10%. Such small reductions might not be important for injury reduction. It has been suggested that changes in material properties might produce adjustments in the muscular response of the locomotor system. The foot has various sensors to detect input signals with subject specific thresholds. Subjects with similar sensitivity threshold levels seem to respond in their movement pattern in a similar way. Comfort is an important variable. From a biomechanical point of view, comfort may be related to fit, additional stabilizing muscle work, fatigue, and damping of soft tissue vibrations. Based on the presented evidence, the concept of minimizing muscle work is proposed when using orthotics or inserts. A force signal acts as an input variable on the shoe. The shoe sole acts as a first filter, the insert or orthotic as a second filter, the plantar surface of the foot as a third filter for the force input signal. The filtered information is transferred to the central nervous system that provides a subject specific dynamic response. The subject performs the movement for the task at hand. For a given movement task, the skeleton has a preferred path. If an intervention supports/counteracts the preferred movement path, muscle activity can/must be

  17. OECA Annual Report 2015 Data Package

    Data.gov (United States)

    U.S. Environmental Protection Agency — This downloadable data package shows information on enforcement actions and cases from 2015. They include civil enforcement actions taken by EPA at facilities,...

  18. micromap: A Package for Linked Micromaps

    Science.gov (United States)

    The R package micromap is used to create linked micromaps, which display statistical summaries associated with areal units, or polygons. Linked micromaps provide a means to simultaneously summarize and display both statistical and geographic distributions by linking statistical ...

  19. GRIP LIGHTNING INSTRUMENT PACKAGE (LIP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The Lightning Instrument Package (LIP) consists of 6 rotating vane type electric field sensors along with a central computer to record and monitor the instruments....

  20. Improvement in Space Food Packaging Methods Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The Space Food Systems Laboratory's (SFSL) current Bulk Overwrap Bag (BOB) package, while simple and effective, leaves room for improvement. Currently, BOBs are...

  1. Development of polymer packaging for power cable

    Directory of Open Access Journals (Sweden)

    S. Sremac

    2014-10-01

    Full Text Available This paper discusses the issues of product design and the procedure of developing polymer packaging as one of the most important engineering tasks. For the purpose of packing power cables a polymer packaging has been designed in the form of drum. Packaging and many other consumer products are largely produced using polymeric materials due to many positive features. High Density Polyethylene is the type of polyethylene proposed for packaging purposes due to its low degree of branching and strong intermolecular forces. Transport and storage processes were automated based on the radio-frequency identification technology. The proposed system is flexible in terms of its possibility of accepting and processing different types of cables and other products.

  2. Solder Mounting Technologies for Electronic Packaging

    Energy Technology Data Exchange (ETDEWEB)

    VIANCO, PAUL T.

    1999-09-23

    Soldering provides a cost-effective means for attaching electronic packages to circuit boards using both small scale and large scale manufacturing processes. Soldering processes accommodate through-hole leaded components as well as surface mount packages, including the newer area array packages such as the Ball Grid Arrays (BGA), Chip Scale Packages (CSP), and Flip Chip Technology. The versatility of soldering is attributed to the variety of available solder alloy compositions, substrate material methodologies, and different manufacturing processes. For example, low melting temperature solders are used with temperature sensitive materials and components. On the other hand, higher melting temperature solders provide reliable interconnects for electronics used in high temperature service. Automated soldering techniques can support large-volume manufacturing processes, while providing high reliability electronic products at a reasonable cost.

  3. Waste Package Component Design Methodology Report

    Energy Technology Data Exchange (ETDEWEB)

    D.C. Mecham

    2004-07-12

    This Executive Summary provides an overview of the methodology being used by the Yucca Mountain Project (YMP) to design waste packages and ancillary components. This summary information is intended for readers with general interest, but also provides technical readers a general framework surrounding a variety of technical details provided in the main body of the report. The purpose of this report is to document and ensure appropriate design methods are used in the design of waste packages and ancillary components (the drip shields and emplacement pallets). The methodology includes identification of necessary design inputs, justification of design assumptions, and use of appropriate analysis methods, and computational tools. This design work is subject to ''Quality Assurance Requirements and Description''. The document is primarily intended for internal use and technical guidance for a variety of design activities. It is recognized that a wide audience including project management, the U.S. Department of Energy (DOE), the U.S. Nuclear Regulatory Commission, and others are interested to various levels of detail in the design methods and therefore covers a wide range of topics at varying levels of detail. Due to the preliminary nature of the design, readers can expect to encounter varied levels of detail in the body of the report. It is expected that technical information used as input to design documents will be verified and taken from the latest versions of reference sources given herein. This revision of the methodology report has evolved with changes in the waste package, drip shield, and emplacement pallet designs over many years and may be further revised as the design is finalized. Different components and analyses are at different stages of development. Some parts of the report are detailed, while other less detailed parts are likely to undergo further refinement. The design methodology is intended to provide designs that satisfy the safety

  4. Production Recesses for Replaceable Cutting Inserts of Milling Tools

    Science.gov (United States)

    Kousal, Lukáš; Sadílek, Marek

    2014-12-01

    This article describes the production of recesses for replaceable cutting inserts of milling tools. The recess manufacture is exemplified on a D20 shanktype milling cutter with three replaceable cutting inserts. A new production technology and its operating cycle are demonstrated. A com-parison of the old and the new technologies shows the percentage saving of change cycles and used tools, including overall evaluation of the tech-nology.

  5. Breakage of an Epidural Catheter Inserted for Labor Analgesia

    OpenAIRE

    Üşar, Pınar; Kar, Aysun Afife; Çıtak, Güven; Maral, Jale; Canlı, Şeyda

    2015-01-01

    The breakage of an epidural catheter, which is usually not noticed, is a rare but important complication encountered while inserting or removing the catheter during epidural blockade. While the epidural catheter was being inserted for labor analgesia, despite no problem being encountered in advancing the catheter, it was drawn back to verify the location; it was observed that 2 cm of the distal end of the catheter was missing. A neurosurgical consultation was requested; it was reported that t...

  6. Metal-Matrix Composite Parts With Metal Inserts

    Science.gov (United States)

    Majkowski, T.; Kashalikar, U.

    1995-01-01

    Developmental fabrication process produces metal-matrix composite (MMC) parts with integral metal inserts. With inserts, MMC parts readily joined to similar parts by use of brazing, welding, or mechanical fasteners. Process conceived to make strong, lightweight components of structures erected in outer space. Also useful on Earth, in such automotive parts as rocker arms, cylinder liners, and pistons. Potential industrial applications include parts subjected to high stresses at high temperatures, as in power-generation, mining, and oil-drilling equipment.

  7. Insertion Loss Analysis of the Acoustic Panels with Composite Construction

    Directory of Open Access Journals (Sweden)

    Vasile Ovidiu

    2013-09-01

    Full Text Available In order to reduce noise pollution, under European legislation in our country need to align, a special attention has the tests carried out on acoustic panels. The most eloquent attempts, defining traffic noise attenuation are tests that can determine the insertion loss of an acoustic screen. In this paper, it briefly shows the method of determining the insertion loss in octave bands and some real results in the case of acoustic panel in a composite construction.

  8. Histological analysis of the tibial anterior cruciate ligament insertion.

    Science.gov (United States)

    Oka, Shinya; Schuhmacher, Peter; Brehmer, Axel; Traut, Ulrike; Kirsch, Joachim; Siebold, Rainer

    2016-03-01

    This study was performed to investigate the morphology of the tibial anterior cruciate ligament (ACL) by histological assessment. The native (undissected) tibial ACL insertion of six fresh-frozen cadaveric knees was cut into four sagittal sections parallel to the long axis of the medial tibial spine. For histological evaluation, the slices were stained with haematoxylin and eosin, Safranin O and Russell-Movat pentachrome. All slices were digitalized and analysed at a magnification of 20×. The anterior tibial ACL insertion was bordered by a bony anterior ridge. The most medial ACL fibres inserted from the medial tibial spine and were adjacent to the articular cartilage of the medial tibial plateau. Parts of the bony insertions of the anterior and posterior horns of the lateral meniscus were in close contact with the lateral part of the tibial ACL insertion. A small fat pad was located just posterior to the functional ACL fibres. The anterior-posterior length of the medial ACL insertion was an average of 10.8 ± 1.1 mm compared with the lateral, which was only 6.2 ± 1.1 mm (p foot-like'. In contrast to previous findings, the functional mid-substance fibres arose from the most posterior part of the 'duck-foot' in a flat and 'c-shaped' way. The most anterior part of the tibial ACL insertion was bordered by a bony anterior ridge and the most medial by the medial tibial spine. No posterolateral fibres nor ACL bundles have been found histologically. This histological investigation may improve our understanding of the tibial ACL insertion and may provide important information for anatomical ACL reconstruction.

  9. Proximal Junctional Kyphosis After Vertical Expandable Prosthetic Titanium Rib Insertion.

    Science.gov (United States)

    Li, Ying; Gold, Meryl; Karlin, Lawrence

    2013-11-01

    Retrospective review of patients who had undergone vertical expandable prosthetic titanium rib (VEPTR) treatment at a single institution. To evaluate whether clinically significant proximal junctional kyphosis (PJK) occurs after VEPTR insertion. PJK is a potential problem after posterior spinal instrumentation and fusion. PJK after VEPTR insertion has not been well-described. A total of 68 patients underwent VEPTR treatment between 1999 and 2009. Diagnosis, age at time of VEPTR insertion, location of VEPTR anchors, preoperative and postoperative scoliosis, T2-T12 kyphosis and PJK, time from VEPTR insertion to development of PJK, revision procedure for significant PJK, change in PJK after the revision procedure, and PJK at final follow-up were recorded. Four patients developed PJK (6%). One patient had congenital scoliosis with rib fusions, 1 had scoliosis associated with a syndrome, and 2 had neuromuscular scoliosis. Mean follow-up was 5.7 years. Average T2-T12 kyphosis and PJK before VEPTR insertion were 77° and 14°, respectively. Mean T2-T12 kyphosis and PJK after VEPTR insertion were 63° and 33°, respectively. Average T2-T12 kyphosis and PJK before the recommended revision procedure for treatment of PJK were 89° and 53°, respectively. All patients developed PJK within the first year after VEPTR insertion. Two patients underwent revision to growing rods. One of these patients had preoperative halo-gravity traction. Mean PJK in these 2 patients improved from 39° to 18° after revision and remained stable at 19° at an average follow-up of 2.9 years. PJK after VEPTR insertion can occur. Patients with preoperative thoracic hyperkyphosis may be at higher risk. PJK can develop within the first year of VEPTR treatment, and can become progressive and severe enough to require complex interventions. In this small case series, patients were revised to growing rods. Copyright © 2013 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.

  10. Lithium Insertion In Silicon Nanowires: An ab Initio Study

    KAUST Repository

    Zhang, Qianfan

    2010-09-08

    The ultrahigh specific lithium ion storage capacity of Si nanowires (SiNWs) has been demonstrated recently and has opened up exciting opportunities for energy storage. However, a systematic theoretical study on lithium insertion in SiNWs remains a challenge, and as a result, understanding of the fundamental interaction and microscopic dynamics during lithium insertion is still lacking. This paper focuses on the study of single Li atom insertion into SiNWs with different sizes and axis orientations by using full ab initio calculations. We show that the binding energy of interstitial Li increases as the SiNW diameter grows. The binding energies at different insertion sites, which can be classified as surface, intermediate, and core sites, are quite different. We find that surface sites are energetically the most favorable insertion positions and that intermediate sites are the most unfavorable insertion positions. Compared with the other growth directions, the [110] SiNWs with different diameters always present the highest binding energies on various insertion locations, which indicates that [110] SiNWs are more favorable by Li doping. Furthermore, we study Li diffusion inside SiNWs. The results show that the Li surface diffusion has a much higher chance to occur than the surface to core diffusion, which is consistent with the experimental observation that the Li insertion in SiNWs is layer by layer from surface to inner region. After overcoming a large barrier crossing surface-to-intermediate region, the diffusion toward center has a higher possibility to occur than the inverse process. © 2010 American Chemical Society.

  11. Blind bedside insertion of small bowel feeding tubes.

    LENUS (Irish Health Repository)

    Duggan, SN

    2009-12-01

    The use of Naso-Jejunal (NJ) feeding is limited by difficulty in feeding tube placement. Patients have traditionally required transfer to Endoscopy or Radiology for insertion of small bowel feeding tubes, with clear resource implications. We hypothesised that the adoption of a simple bedside procedure would be effective and reduce cost. Clinical nutrition and nurse specialist personnel were trained in the 10\\/10\\/10 method of blind bedside NJ insertion.

  12. Deep electrode insertion and sound coding in cochlear implants.

    Science.gov (United States)

    Hochmair, Ingeborg; Hochmair, Erwin; Nopp, Peter; Waller, Melissa; Jolly, Claude

    2015-04-01

    Present-day cochlear implants demonstrate remarkable speech understanding performance despite the use of non-optimized coding strategies concerning the transmission of tonal information. Most systems rely on place pitch information despite possibly large deviations from correct tonotopic placement of stimulation sites. Low frequency information is limited as well because of the constant pulse rate stimulation generally used and, being even more restrictive, of the limited insertion depth of the electrodes. This results in a compromised perception of music and tonal languages. Newly available flexible long straight electrodes permit deep insertion reaching the apical region with little or no insertion trauma. This article discusses the potential benefits of deep insertion which are obtained using pitch-locked temporal stimulation patterns. Besides the access to low frequency information, further advantages of deeply inserted long electrodes are the possibility to better approximate the correct tonotopic location of contacts, the coverage of a wider range of cochlear locations, and the somewhat reduced channel interaction due to the wider contact separation for a given number of channels. A newly developed set of strategies has been shown to improve speech understanding in noise and to enhance sound quality by providing a more "natural" impression, which especially becomes obvious when listening to music. The benefits of deep insertion should not, however, be compromised by structural damage during insertion. The small cross section and the high flexibility of the new electrodes can help to ensure less traumatic insertions as demonstrated by patients' hearing preservation rate. This article is part of a Special Issue entitled . Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

  13. HOPSPACK: Hybrid Optimization Parallel Search Package.

    Energy Technology Data Exchange (ETDEWEB)

    Gray, Genetha Anne.; Kolda, Tamara G.; Griffin, Joshua; Taddy, Matt; Martinez-Canales, Monica L.

    2008-12-01

    In this paper, we describe the technical details of HOPSPACK (Hybrid Optimization Parallel SearchPackage), a new software platform which facilitates combining multiple optimization routines into asingle, tightly-coupled, hybrid algorithm that supports parallel function evaluations. The frameworkis designed such that existing optimization source code can be easily incorporated with minimalcode modification. By maintaining the integrity of each individual solver, the strengths and codesophistication of the original optimization package are retained and exploited.4

  14. Design and packaging: Impact to consumer decision

    Directory of Open Access Journals (Sweden)

    Petrašinović Maja

    2002-01-01

    Full Text Available In marketing theory and practice, product packaging is getting more important. Changes in the market give to packaging a multifunctional phenomenon which is more that core product protection. It represent company marketing strategy and it is competitive tool, which needs to be integrated into a marketing plan and adapt to product, brand price distribution and promotion strategy. A focus to this approach is getting to know customer behavior.

  15. MGtoolkit: A python package for implementing metagraphs

    Directory of Open Access Journals (Sweden)

    D. Ranathunga

    2017-01-01

    Full Text Available In this paper we present MGtoolkit : an open-source Python package for implementing metagraphs - a first of its kind. Metagraphs are commonly used to specify and analyse business and computer-network policies alike. MGtoolkit can help verify such policies and promotes learning and experimentation with metagraphs. The package currently provides purely textual output for visualising metagraphs and their analysis results.

  16. Biopreservation in modified atmosphere packaged vegetables

    OpenAIRE

    Bennik, M.H.J.

    1997-01-01


    Recent trends in food preservation are the use of mild preservation techniques, such as modified atmosphere (MA) packaging and refrigeration, to prolong the shelflife of foods without affecting the fresh character of the product. This has resulted in the development of a new generation of chill stored, minimally processed foods, such as vegetables that are packaged under reduced oxygen (0 2 ) and elevated carbon dioxide (C0 ...

  17. Recyclability and the selection of packaging materials

    Science.gov (United States)

    Berry, David

    1992-12-01

    Costs of solid-waste disposal, concern for environmental impact, and "green" marketing opportunities have placed more attention on recyclability of packaging materials. Recyclability is determined not only by the characteristics of materials themselves, but also by the presence or absence of collection facilities, ease of separation, technology for reprocessing, and markets for recovered materials. By these measures, packaging materials are becoming more recyclable and recyclability is growing in importance as a factor in material selection.

  18. Bioplastics and food packaging: A review

    OpenAIRE

    Nafisa Jabeen; Ishrat Majid; Gulzar Ahmad Nayik

    2015-01-01

    Food packaging as a vital part of the subject of food technology is involved with protection and preservation of all types of foods. Due to economical abundance, petrochemical plastics have been largely used as packaging material due to their desirable properties of good barrier properties towards O2, aroma compounds, tensile strength and tear strength. Meanwhile, they have many disadvantages like very low water vapour transmission rate and the major disadvantage is that they are non-biodegra...

  19. Reflections on the Insertion and Fracture Forces of Microneedles.

    Science.gov (United States)

    Ita, Kevin

    2017-01-01

    The use of microneedles for transdermal drug delivery is a feasible alternative to injections and tablets. As different types of microneedles are being developed from a variety of materials, it is important to understand their insertion and fracture forces. In this review, it has been emphasized that for microneedles to be clinically useful, they must penetrate the skin without breaking. It means that the insertion force must be smaller than fracture force. Transdermal experiments involving these forces have been described and theoretical models highlighted. The knowledge of these forces is important for microneedle design and experimental/ clinical use. From an experimental standpoint, different techniques are used to measure insertion and fracture forces. To measure insertion and failure forces, a texture analyzer can be used. In this review, the measurement of insertion and fracture forces has been discussed and their utility in transdermal experiments presented. This review has focused on insertion and failure forces in transdermal drug delivery experiments. Although the question is complex since there is a wide variety of skin models and forces involved, studies carried out in the last few years have thrown more light to aid better understanding of these forces in transdermal drug delivery research. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  20. Minimally invasive technique for insertion of ventriculopleural shunt catheters.

    Science.gov (United States)

    Richardson, Marlin Dustin; Handler, Michael H

    2013-11-01

    Cerebrospinal fluid diversion to the pleural space has employed various methods to insert the distal catheter into the pleural space. The authors report on a minimally invasive method of pleural catheter insertion that they have developed and have used safely in a small series of patients. Pleural shunt catheters were inserted using a split trochar into the pleural space (technique described in further detail in the article). All cases over the previous 10 years in which this technique was employed were reviewed from the existing electronic medical records. Patient age at insertion, sex, reason for hydrocephalus, early and late complications, valve type, and follow-up were recorded. Fourteen shunt procedures performed in 10 patients were identified. Two small pneumothoraces were detected on routine postoperative imaging and required no intervention. There were 3 late mechanical complications, including migration of a catheter out of the pleural space, catheter fracture at the insertion point, and the need for a longer catheter due to the patient's growth. The authors describe a safe, minimally invasive method for insertion of pleural shunt catheters along with a series of patients who have undergone placement of a pleural shunt catheter using this method without complication directly attributable to the use of this technique.

  1. A new specifically designed forceps for chest drain insertion.

    LENUS (Irish Health Repository)

    Andrews, Emmet

    2012-02-03

    Insertion of a chest drain can be associated with serious complications. It is recommended that the drain is inserted with blunt dissection through the chest wall but there is no specific instrument to aid this task. We describe a new reusable forceps that has been designed specifically to facilitate the insertion of chest drains.A feasibility study of its use in patients who required a chest drain as part of elective cardiothoracic operations was undertaken. The primary end-point was successful and accurate placement of the drain. The operators also completed a questionnaire rating defined aspects of the procedure. The new instrument was used to insert the chest drain in 30 patients (19 male, 11 female; median age 61.5 years (range 16-81 years)). The drain was inserted successfully without the trocar in all cases and there were no complications. Use of the instrument rated as significantly easier relative to experience of previous techniques in all specified aspects. The new device can be used to insert intercostal chest drains safely and efficiently without using the trocar or any other instrument.

  2. Sensorless motion planning for medical needle insertion in deformable tissues.

    Science.gov (United States)

    Alterovitz, Ron; Goldberg, Kenneth Y; Pouliot, Jean; Hsu, I-Chow Joe

    2009-03-01

    Minimally invasive medical procedures such as biopsies, anesthesia drug injections, and brachytherapy cancer treatments require inserting a needle to a specific target inside soft tissues. This is difficult because needle insertion displaces and deforms the surrounding soft tissues causing the target to move during the procedure. To facilitate physician training and preoperative planning for these procedures, we develop a needle insertion motion planning system based on an interactive simulation of needle insertion in deformable tissues and numerical optimization to reduce placement error. We describe a 2-D physically based, dynamic simulation of needle insertion that uses a finite-element model of deformable soft tissues and models needle cutting and frictional forces along the needle shaft. The simulation offers guarantees on simulation stability for mesh modifications and achieves interactive, real-time performance on a standard PC. Using texture mapping, the simulation provides visualization comparable to ultrasound images that the physician would see during the procedure. We use the simulation as a component of a sensorless planning algorithm that uses numerical optimization to compute needle insertion offsets that compensate for tissue deformations. We apply the method to radioactive seed implantation during permanent seed prostate brachytherapy to minimize seed placement error.

  3. Templated sequence insertion polymorphisms in the human genome

    Science.gov (United States)

    Onozawa, Masahiro; Aplan, Peter

    2016-11-01

    Templated Sequence Insertion Polymorphism (TSIP) is a recently described form of polymorphism recognized in the human genome, in which a sequence that is templated from a distant genomic region is inserted into the genome, seemingly at random. TSIPs can be grouped into two classes based on nucleotide sequence features at the insertion junctions; Class 1 TSIPs show features of insertions that are mediated via the LINE-1 ORF2 protein, including 1) target-site duplication (TSD), 2) polyadenylation 10-30 nucleotides downstream of a “cryptic” polyadenylation signal, and 3) preference for insertion at a 5’-TTTT/A-3’ sequence. In contrast, class 2 TSIPs show features consistent with repair of a DNA double-strand break via insertion of a DNA “patch” that is derived from a distant genomic region. Survey of a large number of normal human volunteers demonstrates that most individuals have 25-30 TSIPs, and that these TSIPs track with specific geographic regions. Similar to other forms of human polymorphism, we suspect that these TSIPs may be important for the generation of human diversity and genetic diseases.

  4. Smart packaging systems for food applications: a review.

    Science.gov (United States)

    Biji, K B; Ravishankar, C N; Mohan, C O; Srinivasa Gopal, T K

    2015-10-01

    Changes in consumer preference for safe food have led to innovations in packaging technologies. This article reviews about different smart packaging systems and their applications in food packaging, packaging research with latest innovations. Active and intelligent packing are such packaging technologies which offer to deliver safer and quality products. Active packaging refers to the incorporation of additives into the package with the aim of maintaining or extending the product quality and shelf life. The intelligent systems are those that monitor the condition of packaged food to give information regarding the quality of the packaged food during transportation and storage. These technologies are designed to the increasing demand for safer foods with better shelf life. The market for active and intelligent packaging systems is expected to have a promising future by their integration into packaging materials or systems.

  5. Development directions of packaging made from polymer materials

    Directory of Open Access Journals (Sweden)

    Jovanović Slobodan

    2011-01-01

    Full Text Available World packaging market achieves turnover of about $620 billion per year with one third of this amount being associated to packaging made from polymer materials. It is expected that this kind of packaging consumption will hold at least 3% of world packaging market share in the next five years and that it will surpass the consumption of all other materials used in the packaging production. This can be contributed to product quality, low production costs as well as significant investments made in the development of polymer materials, packaging technology and packaging. This paper presents some development directions for packaging made from polymer materials, such as: packaging in the protective atmosphere, the use of active and intelligent packaging, and the use of biopolymers and recycled polymers for packaging production that come into direct contact with the packed product.

  6. Severities of transportation accidents involving large packages

    Energy Technology Data Exchange (ETDEWEB)

    Dennis, A.W.; Foley, J.T. Jr.; Hartman, W.F.; Larson, D.W.

    1978-05-01

    The study was undertaken to define in a quantitative nonjudgmental technical manner the abnormal environments to which a large package (total weight over 2 tons) would be subjected as the result of a transportation accident. Because of this package weight, air shipment was not considered as a normal transportation mode and was not included in the study. The abnormal transportation environments for shipment by motor carrier and train were determined and quantified. In all cases the package was assumed to be transported on an open flat-bed truck or an open flat-bed railcar. In an earlier study, SLA-74-0001, the small-package environments were investigated. A third transportation study, related to the abnormal environment involving waterways transportation, is now under way at Sandia Laboratories and should complete the description of abnormal transportation environments. Five abnormal environments were defined and investigated, i.e., fire, impact, crush, immersion, and puncture. The primary interest of the study was directed toward the type of large package used to transport radioactive materials; however, the findings are not limited to this type of package but can be applied to a much larger class of material shipping containers.

  7. Naming, labeling, and packaging of pharmaceuticals.

    Science.gov (United States)

    Kenagy, J W; Stein, G C

    2001-11-01

    The problem of medical errors associated with the naming, labeling, and packaging of pharmaceuticals is discussed. Sound-alike and look-alike drug names and packages can lead pharmacists and nurses to unintended interchanges of drugs that can result in patient injury or death. The existing medication-use system is flawed because its safety depends on human perfection. Simplicity, standardization, differentiation, lack of duplication, and unambiguous communication are human factors concepts that are relevant to the medication-use process. These principles have often been ignored in drug naming, labeling, and packaging. Instead, current methods are based on long-standing commercial considerations and bureaucratic procedures. The process for naming a marketable drug is lengthy and complex and involves submission of a new chemical entity and patent application, generic naming, brand naming, FDA review, and final approval. Drug companies seek the fastest possible approval and may believe that the incremental benefit of human factors evaluation is small. "Trade dress" is the concept that underlies labeling and packaging issues for the drug industry. Drug companies are resistant to changing trade dress and brand names. Although a variety of private-sector organizations have called for reforms in drug naming, labeling, and packaging standards have been proposed, the problem remains. Drug names, labels, and packages are not selected and designed in accordance with human factors principles. FDA standards do not require application of these principles, the drug industry has struggled with change, and private-sector initiatives have had only limited success.

  8. Time temperature indicators as devices intelligent packaging

    Directory of Open Access Journals (Sweden)

    Adriana Pavelková

    2013-01-01

    Full Text Available Food packaging is an important part of food production. Temperature is a one of crucial factor which affecting the quality and safety of food products during distribution, transport and storage. The one way of control of food quality and safety is the application of new packaging systems, which also include the intelligent or smart packaging. Intelligent packaging is a packaging system using different indicators for monitoring the conditions of production, but in particular the conditions during transport and storage. Among these indicators include the time-temperature indicators to monitor changes in temperature, which is exposed the product and to inform consumers about the potential risks associated with consumption of these products. Time temperature indicators are devices that show an irreversible change in a physical characteristic, usually color or shape, in response to temperature history. Some are designed to monitor the evolution of temperature with time along the distribution chain and others are designed to be used in the consumer packages.

  9. Antimicrobial food packaging: potential and pitfalls

    Science.gov (United States)

    Malhotra, Bhanu; Keshwani, Anu; Kharkwal, Harsha

    2015-01-01

    Nowadays food preservation, quality maintenance, and safety are major growing concerns of the food industry. It is evident that over time consumers’ demand for natural and safe food products with stringent regulations to prevent food-borne infectious diseases. Antimicrobial packaging which is thought to be a subset of active packaging and controlled release packaging is one such promising technology which effectively impregnates the antimicrobial into the food packaging film material and subsequently delivers it over the stipulated period of time to kill the pathogenic microorganisms affecting food products thereby increasing the shelf life to severe folds. This paper presents a picture of the recent research on antimicrobial agents that are aimed at enhancing and improving food quality and safety by reduction of pathogen growth and extension of shelf life, in a form of a comprehensive review. Examination of the available antimicrobial packaging technologies is also presented along with their significant impact on food safety. This article entails various antimicrobial agents for commercial applications, as well as the difference between the use of antimicrobials under laboratory scale and real time applications. Development of resistance amongst microorganisms is considered as a future implication of antimicrobials with an aim to come up with actual efficacies in extension of shelf life as well as reduction in bacterial growth through the upcoming and promising use of antimicrobials in food packaging for the forthcoming research down the line. PMID:26136740

  10. Evaluation of molecular assays for identification Campylobacter fetus species and subspecies and development of a C. fetus specific real-time PCR assay.

    Science.gov (United States)

    van der Graaf-van Bloois, Linda; van Bergen, Marcel A P; van der Wal, Fimme J; de Boer, Albert G; Duim, Birgitta; Schmidt, Tracy; Wagenaar, Jaap A

    2013-10-01

    Phenotypic differentiation between Campylobacter fetus (C. fetus) subspecies fetus and C. fetus subspecies venerealis is hampered by poor reliability and reproducibility of biochemical assays. AFLP (amplified fragment length polymorphism) and MLST (multilocus sequence typing) are the molecular standards for C. fetus subspecies identification, but these methods are laborious and expensive. Several PCR assays for C. fetus subspecies identification have been described, but a reliable comparison of these assays is lacking. The aim of this study was to evaluate the most practical and routinely implementable published PCR assays designed for C. fetus species and subspecies identification. The sensitivity and specificity of the assays were calculated by using an extensively characterized and diverse collection of C. fetus strains. AFLP and MLST identification were used as reference. Two PCR assays were able to identify C. fetus strains correctly at species level. The C. fetus species identification target, gene nahE, of one PCR assay was used to develop a real-time PCR assay with 100% sensitivity and 100% specificity, but the development of a subspecies venerealis specific real-time PCR (ISCfe1) failed due to sequence variation of the target insertion sequence and prevalence in other Campylobacter species. None of the published PCR assays was able to identify C. fetus strains correctly at subspecies level. Molecular analysis by AFLP or MLST is still recommended to identify C. fetus isolates at subspecies level. © 2013. Published by Elsevier B.V. All rights reserved.

  11. ACTIVE PACKAGING SYSTEM FOR MEAT AND MEAT PRODUCTS

    Directory of Open Access Journals (Sweden)

    Adriana Pavelková

    2012-10-01

    Full Text Available In the recent past, food packaging was used to enable marketing of products and to provide passive protection against environmental contaminations or influences that affect the shelf life of the products. However, unlike traditional packaging, which must be totally inert, active packaging is designed to interact with the contents and/or the surrounding environment. Interest in the use of active packaging systems for meat and meat products has increased in recent years. Active packaging systems are developed with the goal of extending shelf life for foods and increasing the period of time that the food is high quality. Developments in active packaging have led to advances in many areas, including delayed oxidation and controlled respiration rate, microbial growth, and moisture migration. Active packaging technologies include some physical, chemical, or biological action which changes interactions between a package, product, and/or headspace of the package in order to get a desired outcome. Active packaging systems discussed include oxygen scavengers, carbon dioxide scavengers and emitters, moisture control agents, flavour/odour absorbers and releasers  and antimicrobial packaging technologies. Active packaging is typically found in two types of systems; sachets and pads which are placed inside of packages, and active ingredients that are incorporated directly into packaging materials.  Recognition of the benefits of active packaging technologies by the food industry, development of economically viable packaging systems and increased consumer acceptance is necessary for commercial realisation of these packaging technologies.doi:10.5219/205

  12. Sustainable packaging. Packaging for a circular economy; Duurzaam verpakken. Verpakken voor de circulaire economie

    Energy Technology Data Exchange (ETDEWEB)

    Haffmans, S. [Partners for Innovation, Amsterdam (Netherlands); Standhardt, G. [Nederlands Verpaskkingscentrum NVC, Gouda (Netherlands); Hamer, A. [Agentschap NL, Utrecht (Netherlands)

    2013-10-15

    What is Sustainable Packaging? And what is the most sustainable packaging for a product? The publication is intended for anyone who wants to take into account the environment in the design of a product and packaging. It offers concrete suggestions and inspiring examples to bring sustainable packaging into practice [Dutch] Wat is Duurzaam Verpakken? En wat is de duurzaamste verpakking voor mijn product? De publicatie is bestemd voor iedereen die rekening wil houden met het milieu bij het ontwerp van een product-verpakkingscombinatie. Ze biedt concrete aanknopingspunten en inspirerende voorbeelden om hier praktisch mee aan de slag te gaan.

  13. The R package 'icosa' for coarse resolution global triangular and penta-hexagonal gridding

    Science.gov (United States)

    Kocsis, Adam T.

    2017-04-01

    With the development of the internet and the computational power of personal computers, open source programming environments have become indispensable for science in the past decade. This includes the increase of the GIS capacity of the free R environment, which was originally developed for statistical analyses. The flexibility of R made it a preferred programming tool in a multitude of disciplines from the area of the biological and geological sciences. Many of these subdisciplines operate with incidence (occurrence) data that are in a large number of cases to be grained before further analyses can be conducted. This graining is executed mostly by gridding data to cells of a Gaussian grid of various resolutions to increase the density of data in a single unit of the analyses. This method has obvious shortcomings despite the ease of its application: well-known systematic biases are induced to cell sizes and shapes that can interfere with the results of statistical procedures, especially if the number of incidence points influences the metrics in question. The 'icosa' package employs a common method to overcome this obstacle by implementing grids with roughly equal cell sizes and shapes that are based on tessellated icosahedra. These grid objects are essentially polyhedra with xyz Cartesian vertex data that are linked to tables of faces and edges. At its current developmental stage, the package uses a single method of tessellation which balances grid cell size and shape distortions, but its structure allows the implementation of various other types of tessellation algorithms. The resolution of the grids can be set by the number of breakpoints inserted into a segment forming an edge of the original icosahedron. Both the triangular and their inverted penta-hexagonal grids are available for creation with the package. The package also incorporates functions to look up coordinates in the grid very effectively and data containers to link data to the grid structure. The

  14. CRISPR/Cas9 cleavages in budding yeast reveal templated insertions and strand-specific insertion/deletion profiles.

    Science.gov (United States)

    Lemos, Brenda R; Kaplan, Adam C; Bae, Ji Eun; Ferrazzoli, Alexander E; Kuo, James; Anand, Ranjith P; Waterman, David P; Haber, James E

    2018-02-13

    Harnessing CRISPR-Cas9 technology provides an unprecedented ability to modify genomic loci via DNA double-strand break (DSB) induction and repair. We analyzed nonhomologous end-joining (NHEJ) repair induced by Cas9 in budding yeast and found that the orientation of binding of Cas9 and its guide RNA (gRNA) profoundly influences the pattern of insertion/deletions (indels) at the site of cleavage. A common indel created by Cas9 is a 1-bp (+1) insertion that appears to result from Cas9 creating a 1-nt 5' overhang that is filled in by a DNA polymerase and ligated. The origin of +1 insertions was investigated by using two gRNAs with PAM sequences located on opposite DNA strands but designed to cleave the same sequence. These templated +1 insertions are dependent on the X-family DNA polymerase, Pol4. Deleting Pol4 also eliminated +2 and +3 insertions, which are biased toward homonucleotide insertions. Using inverted PAM sequences, we also found significant differences in overall NHEJ efficiency and repair profiles, suggesting that the binding of the Cas9:gRNA complex influences subsequent NHEJ processing. As with events induced by the site-specific HO endonuclease, CRISPR-Cas9-mediated NHEJ repair depends on the Ku heterodimer and DNA ligase 4. Cas9 events are highly dependent on the Mre11-Rad50-Xrs2 complex, independent of Mre11's nuclease activity. Inspection of the outcomes of a large number of Cas9 cleavage events in mammalian cells reveals a similar templated origin of +1 insertions in human cells, but also a significant frequency of similarly templated +2 insertions.

  15. Technological Innovations in the Food Packaging: a case study of adoption of active packaging in coffee roaster companies

    Directory of Open Access Journals (Sweden)

    Mário Otávio Batalha

    2010-12-01

    Full Text Available Most of technological innovations in agro-food systems are created by “supporting industries”, the group where packaging industries are inserted. This article presents the packaging innovations used in food industries, particularly, the active packaging. This paper deals with an adoption case of a degassing one-way valve, describing this innovation and its impacts in two coffee companies. This study can be classified as a documental, qualitative-descriptive and empirical research, using indirect documentation technique and case study analysis. According to this case, the valve made possible the diversification of the company product line and product quality improvement. There were no complications involving an additional cost to the customers. However, it has been observed that this additional cost from technology adoption makes difficult the diffusion of this valve in other similar products.Grande parcela das inovações tecnológicas dos sistemas agroindustriais é gerada pelas “indústrias de apoio”, grupo no qual as indústrias de embalagens se inserem. Esse artigo discute as inovações em embalagens destinadas à indústria de alimentos, em especial as chamadas embalagens ativas. Discute-se o caso de adoção da válvula unidirecional de alívio de gases, descrevendo a inovação e seus impactos em duas indústria processadoras de café nas empresas. A pesquisa desenvolvida é de ordem documental e qualitativo-descritiva de caráter empírica, usando técnica de análise de documentação indireta e estudo de caso . No caso abordado, a válvula possibilitou a diversificação da linha de produtos e o incremento da sua qualidade, não havendo complicações no que se refere ao repasse do custo adicional para o consumidor desse produto. Contudo, verifica-se que esse custo adicional da adoção da tecnologia dificulta a difusão da válvula em produtos similares.

  16. Tobacco packaging design for reducing tobacco use.

    Science.gov (United States)

    McNeill, Ann; Gravely, Shannon; Hitchman, Sara C; Bauld, Linda; Hammond, David; Hartmann-Boyce, Jamie

    2017-04-27

    Tobacco use is the largest single preventable cause of death and disease worldwide. Standardised tobacco packaging is an intervention intended to reduce the promotional appeal of packs and can be defined as packaging with a uniform colour (and in some cases shape and size) with no logos or branding, apart from health warnings and other government-mandated information, and the brand name in a prescribed uniform font, colour and size. Australia was the first country to implement standardised tobacco packaging between October and December 2012, France implemented standardised tobacco packaging on 1 January 2017 and several other countries are implementing, or intending to implement, standardised tobacco packaging. To assess the effect of standardised tobacco packaging on tobacco use uptake, cessation and reduction. We searched MEDLINE, Embase, PsycINFO and six other databases from 1980 to January 2016. We checked bibliographies and contacted study authors to identify additional peer-reviewed studies. Primary outcomes included changes in tobacco use prevalence incorporating tobacco use uptake, cessation, consumption and relapse prevention. Secondary outcomes covered intermediate outcomes that can be measured and are relevant to tobacco use uptake, cessation or reduction. We considered multiple study designs: randomised controlled trials, quasi-experimental and experimental studies, observational cross-sectional and cohort studies. The review focused on all populations and people of any age; to be included, studies had to be published in peer-reviewed journals. We examined studies that assessed the impact of changes in tobacco packaging such as colour, design, size and type of health warnings on the packs in relation to branded packaging. In experiments, the control condition was branded tobacco packaging but could include variations of standardised packaging. Screening and data extraction followed standard Cochrane methods. We used different 'Risk of bias' domains for

  17. Methanol Formation via Oxygen Insertion Chemistry in Ices

    Science.gov (United States)

    Bergner, Jennifer B.; Öberg, Karin I.; Rajappan, Mahesh

    2017-08-01

    We present experimental constraints on the insertion of oxygen atoms into methane to form methanol in astrophysical ice analogs. In gas-phase and theoretical studies this process has previously been demonstrated to have a very low or nonexistent energy barrier, but the energetics and mechanisms have not yet been characterized in the solid state. We use a deuterium UV lamp filtered by a sapphire window to selectively dissociate O2 within a mixture of O2:CH4 and observe efficient production of CH3OH via O(1D) insertion. CH3OH growth curves are fit with a kinetic model, and we observe no temperature dependence of the reaction rate constant at temperatures below the oxygen desorption temperature of 25 K. Through an analysis of side products we determine the branching ratio of ice-phase oxygen insertion into CH4: ˜65% of insertions lead to CH3OH, with the remainder leading instead to H2CO formation. There is no evidence for CH3 or OH radical formation, indicating that the fragmentation is not an important channel and that insertions typically lead to increased chemical complexity. CH3OH formation from O2 and CH4 diluted in a CO-dominated ice similarly shows no temperature dependence, consistent with expectations that insertion proceeds with a small or nonexistent barrier. Oxygen insertion chemistry in ices should therefore be efficient under low-temperature ISM-like conditions and could provide an important channel to complex organic molecule formation on grain surfaces in cold interstellar regions such as cloud cores and protoplanetary disk midplanes.

  18. Methanol Formation via Oxygen Insertion Chemistry in Ices

    Energy Technology Data Exchange (ETDEWEB)

    Bergner, Jennifer B. [Harvard University Department of Chemistry and Chemical Biology, 10 Oxford Street, Cambridge, MA 02138 (United States); Öberg, Karin I.; Rajappan, Mahesh [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States)

    2017-08-10

    We present experimental constraints on the insertion of oxygen atoms into methane to form methanol in astrophysical ice analogs. In gas-phase and theoretical studies this process has previously been demonstrated to have a very low or nonexistent energy barrier, but the energetics and mechanisms have not yet been characterized in the solid state. We use a deuterium UV lamp filtered by a sapphire window to selectively dissociate O{sub 2} within a mixture of O{sub 2}:CH{sub 4} and observe efficient production of CH{sub 3}OH via O({sup 1}D) insertion. CH{sub 3}OH growth curves are fit with a kinetic model, and we observe no temperature dependence of the reaction rate constant at temperatures below the oxygen desorption temperature of 25 K. Through an analysis of side products we determine the branching ratio of ice-phase oxygen insertion into CH{sub 4}: ∼65% of insertions lead to CH{sub 3}OH, with the remainder leading instead to H{sub 2}CO formation. There is no evidence for CH{sub 3} or OH radical formation, indicating that the fragmentation is not an important channel and that insertions typically lead to increased chemical complexity. CH{sub 3}OH formation from O{sub 2} and CH{sub 4} diluted in a CO-dominated ice similarly shows no temperature dependence, consistent with expectations that insertion proceeds with a small or nonexistent barrier. Oxygen insertion chemistry in ices should therefore be efficient under low-temperature ISM-like conditions and could provide an important channel to complex organic molecule formation on grain surfaces in cold interstellar regions such as cloud cores and protoplanetary disk midplanes.

  19. Enhanced pH-Responsiveness, Cellular Trafficking, Cytotoxicity and Long-circulation of PEGylated Liposomes with Post-insertion Technique Using Gemcitabine as a Model Drug.

    Science.gov (United States)

    Xu, Hongtao; Paxton, James W; Wu, Zimei

    2015-07-01

    The in vitro and in vivo properties of PEGylated pH-sensitive liposomes (PSL) prepared by pre- and post-insertion techniques were investigated. A pre-insertion or post-insertion technique was used for PSL PEGylation. For the first time, confocal laser scanning microscopy coupled with a modified calcein self-quench assay was applied to evaluate the endosome escape capability. PSL cellular uptake was evaluated using macrophages and the cytotoxicity using a gemcitabine (model drug)-resistant MIA PaCa-2 cells. The pharmacokinetics of PSL encapsulated gemcitabine was investigated in rats. PEGylation reduced the pH-sensitivity in a concentration-dependent manner (0.5-5% mol). Both PEGylation methods reduced the uptake of PSL by macrophages by over 60%. Cytotoxicity was ranked in the order: post-inserted PSL ≥ pre-inserted PSL > non-PSL > gemcitabine solution, consistent with the confocal microscopic observation and pH-sensitivity. Both pre and post-inserted PSL resulted in significant reductions (p pH-sensitivity, more effective intra-cytoplasmic delivery, and a superior pharmacokinetics.

  20. Wrapping up your message : Sustainable storytelling through packaging

    NARCIS (Netherlands)

    Wever, R.; Schermer, R.; Smit, L.; Vos, L.

    2015-01-01

    Besides contributing to the actual sustainability performance of a product-packaging combination, packaging can also play a role in communicating about sustainability. Such green marketing aspects of packaging may either focus on the sustainability credentials of the packaging itself, or on the

  1. 30 CFR 7.108 - Power package checklist.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Power package checklist. 7.108 Section 7.108... checklist. Each diesel power package bearing an MSHA approval plate shall be accompanied by a power package checklist. The power package checklist shall consist of a list of specific features that must be checked and...

  2. 49 CFR 173.465 - Type A packaging tests.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Type A packaging tests. 173.465 Section 173.465... SHIPMENTS AND PACKAGINGS Class 7 (Radioactive) Materials § 173.465 Type A packaging tests. (a) The packaging... deformation upon impact by the specimen would not significantly increase the damage to the specimen. (d...

  3. 19 CFR 10.461 - Retail packaging materials and containers.

    Science.gov (United States)

    2010-04-01

    ... Free Trade Agreement Rules of Origin § 10.461 Retail packaging materials and containers. Packaging materials and containers in which a good is packaged for retail sale, if classified with the good for which... 19 Customs Duties 1 2010-04-01 2010-04-01 false Retail packaging materials and containers. 10.461...

  4. 19 CFR 10.539 - Retail packaging materials and containers.

    Science.gov (United States)

    2010-04-01

    ...-Singapore Free Trade Agreement Rules of Origin § 10.539 Retail packaging materials and containers. Packaging materials and containers in which a good is packaged for retail sale, if classified with the good for which... 19 Customs Duties 1 2010-04-01 2010-04-01 false Retail packaging materials and containers. 10.539...

  5. Sulforhodamine B assay and chemosensitivity.

    Science.gov (United States)

    Voigt, Wieland

    2005-01-01

    The sulforhodamine B (SRB) assay was developed by Skehan and colleagues to measure drug-induced cytotoxicity and cell proliferation for large-scale drug-screening applications. Its principle is based on the ability of the protein dye sulforhodamine B to bind electrostatically and pH dependent on protein basic amino acid residues of trichloroacetic acid-fixed cells. Under mild acidic conditions it binds to and under mild basic conditions it can be extracted from cells and solubilized for measurement. Results of the SRB assay were linear with cell number and cellular protein measured at cellular densities ranging from 1 to 200% of confluence. Its sensitivity is comparable with that of several fluorescence assays and superior to that of Lowry or Bradford. The signal-to-noise ratio is favorable and the resolution is 1000-2000 cells/well. It performed similarly compared to other cytotoxicity assays such as MTT or clonogenic assay. The SRB assay possesses a colorimetric end point and is nondestructive and indefinitely stable. These practical advances make the SRB assay an appropriate and sensitive assay to measure drug-induced cytotoxicity even at large-scale application.

  6. US Army Radiological Bioassay and Dosimetry: The RBD software package

    Energy Technology Data Exchange (ETDEWEB)

    Eckerman, K. F.; Ward, R. C.; Maddox, L. B.

    1993-01-01

    The RBD (Radiological Bioassay and Dosimetry) software package was developed for the U. S. Army Material Command, Arlington, Virginia, to demonstrate compliance with the radiation protection guidance 10 CFR Part 20 (ref. 1). Designed to be run interactively on an IBM-compatible personal computer, RBD consists of a data base module to manage bioassay data and a computational module that incorporates algorithms for estimating radionuclide intake from either acute or chronic exposures based on measurement of the worker's rate of excretion of the radionuclide or the retained activity in the body. In estimating the intake,RBD uses a separate file for each radionuclide containing parametric representations of the retention and excretion functions. These files also contain dose-per-unit-intake coefficients used to compute the committed dose equivalent. For a given nuclide, if measurements exist for more than one type of assay, an auxiliary module, REPORT, estimates the intake by applying weights assigned in the nuclide file for each assay. Bioassay data and computed results (estimates of intake and committed dose equivalent) are stored in separate data bases, and the bioassay measurements used to compute a given result can be identified. The REPORT module creates a file containing committed effective dose equivalent for each individual that can be combined with the individual's external exposure.

  7. Digital Assays Part II: Digital Protein and Cell Assays.

    Science.gov (United States)

    Basu, Amar S

    2017-08-01

    A digital assay is one in which the sample is partitioned into many containers such that each partition contains a discrete number of biological entities (0, 1, 2, 3, . . .). A powerful technique in the biologist's toolkit, digital assays bring a new level of precision in quantifying nucleic acids, measuring proteins and their enzymatic activity, and probing single-cell genotype and phenotype. Where part I of this review focused on the fundamentals of partitioning and digital PCR, part II turns its attention to digital protein and cell assays. Digital enzyme assays measure the kinetics of single proteins with enzymatic activity. Digital enzyme-linked immunoassays (ELISAs) quantify antigenic proteins with 2 to 3 log lower detection limit than conventional ELISA, making them well suited for low-abundance biomarkers. Digital cell assays probe single-cell genotype and phenotype, including gene expression, intracellular and surface proteins, metabolic activity, cytotoxicity, and transcriptomes (scRNA-seq). These methods exploit partitioning to 1) isolate single cells or proteins, 2) detect their activity via enzymatic amplification, and 3) tag them individually by coencapsulating them with molecular barcodes. When scaled, digital assays reveal stochastic differences between proteins or cells within a population, a key to understanding biological heterogeneity. This review is intended to give a broad perspective to scientists interested in adopting digital assays into their workflows.

  8. Disagreement between Human Papillomavirus Assays

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Preisler, Sarah; Ejegod, Ditte Møller

    2014-01-01

    We aimed to determine the disagreement in primary cervical screening between four human papillomavirus assays: Hybrid Capture 2, cobas, CLART, and APTIMA. Material from 5,064 SurePath samples of women participating in routine cervical screening in Copenhagen, Denmark, was tested with the four...... of considerable disagreement between human papillomavirus assays. This suggested that the extent of disagreement in primary screening is neither population- nor storage media-specific, leaving assay design differences as the most probable cause. The substantially different selection of women testing positive...... on the various human papillomavirus assays represents an unexpected challenge for the choice of an assay in primary cervical screening, and for follow up of in particular HPV positive/cytology normal women....

  9. Immediate post-abortal insertion of intrauterine devices.

    Science.gov (United States)

    Grimes, D; Schulz, K; Stanwood, N

    2000-01-01

    To assess the safety and efficacy of IUD insertion immediately after spontaneous or induced abortion. We used Medline, Popline, and EMBASE computer searches, supplemented by review articles and contacts with investigators. We sought all randomized controlled trials that had at least one treatment arm that involved IUD insertion immediately after an induced abortion or after curettage for spontaneous abortion. We identified 12 trials which described random assignment but excluded three from this review. Two of these revealed unethical research conduct, and one used alternate assignment to treatments. We evaluated the methodological quality of each report and abstracted information onto a data collection form. We focused on gross discontinuation rates (single-decrement life table analysis) for accidental pregnancy, perforation, expulsion, and pelvic inflammatory disease. We entered the data into RevMan 3.1 for analysis of Peto odds ratios. In large multicenter trials, the TCu 220C device proved superior to either the Lippes Loop D or the Copper 7 IUDs for immediate post-abortal insertion. The Peto OR for discontinuation for pregnancy was 0.4 (95% CI 0.2-0.7) compared with the Lippes Loop D and 0.5 (95% CI 0.3-0.8) compared with the Copper 7. Expulsions were also significantly less common with the TCu 220C than with the other two IUDs. In single-center trials, the Nova T IUD had a signicantly higher discontinuation rate for pregnancy than did the Multiload 250 (OR 4.5; 95% CI 1.0-19.8), while the Nova T had a significantly lower discontinuation rate for pregnancy than did the TCu 200 (OR 0.3; 95% CI 0.1-0.9). Only one trial compared immediate vs. delayed insertion. In this trial, the performance of the Copper 7 IUD inserted immediately after abortion was inferior to that after interval insertion (remote from pregnancy), although the differences were not statistically significant. Addition of copper sleeves to a Lippes Loop D improved its performance, but addition of a

  10. The Significance of Placental Cord Insertion Site in Twin Pregnancy.

    Science.gov (United States)

    Kalafat, Erkan; Thilaganathan, Basky; Papageorghiou, Aris; Bhide, Amar; Khalil, Asma

    2017-10-04

    The aim of this study was to investigate the association between abnormal cord insertion and the development of the twin-specific complications, including birthweight discordance, selective fetal growth restriction (sFGR) and twin-to-twin transfusion syndrome (TTTS). A single-center cohort study of twin pregnancies. Abnormal cord insertion was defined as either marginal (cord attachment site less than 2cm to the nearest margin of the placental disc) or velamentous (when the umbilical cord was attached to the membrane before reaching the placental disc with clear evidence of vessels traversing the membranes to connect with the placental disc), as described in placental pathology reports. Major structural or chromosomal abnormalities and monochorionic monoamniotic twins were not included in the study. Information on the pregnancies, ultrasound findings, prenatal investigation and interventions was obtained from the electronic ultrasound database, while data on the placental histopathological findings, pregnancy outcomes, mode of delivery, birthweight, gestational age at delivery, and admission to the neonatal intensive care unit (NICU) were obtained from the maternity records. Categorical variables were compared by the X2 -test or Fisher's exact test, while continuous variables were compared using the t-test, analysis of variance (ANOVA) for multiple comparison and the Kruskal-Wallis test. 497 twin pregnancies, 351 (70.6%) dichorionic and 146 (29.3%) monochorionic, were included in the analysis. The incidence of birthweight discordance of 25% or more was significantly higher in pregnancies with velamentous and marginal cord insertions compared to those with normal cord insertion (24.5%, 15.2% vs 7.5%, Pcord insertions compared to the larger twins (1.8% and 18.5%, respectively Pcord insertions (40.9%) compared to the larger twins (2.3% and 29.5%, respectively Pcord insertion group, only velamentous insertion was significantly associated with the risk of sFGR (OR 9

  11. Focus on peripherally inserted central catheters in critically ill patients.

    Science.gov (United States)

    Cotogni, Paolo; Pittiruti, Mauro

    2014-11-04

    Venous access devices are of pivotal importance for an increasing number of critically ill patients in a variety of disease states and in a variety of clinical settings (emergency, intensive care, surgery) and for different purposes (fluids or drugs infusions, parenteral nutrition, antibiotic therapy, hemodynamic monitoring, procedures of dialysis/apheresis). However, healthcare professionals are commonly worried about the possible consequences that may result using a central venous access device (CVAD) (mainly, bloodstream infections and thrombosis), both peripherally inserted central catheters (PICCs) and centrally inserted central catheters (CICCs). This review aims to discuss indications, insertion techniques, and care of PICCs in critically ill patients. PICCs have many advantages over standard CICCs. First of all, their insertion is easy and safe -due to their placement into peripheral veins of the arm- and the advantage of a central location of catheter tip suitable for all osmolarity and pH solutions. Using the ultrasound-guidance for the PICC insertion, the risk of hemothorax and pneumothorax can be avoided, as well as the possibility of primary malposition is very low. PICC placement is also appropriate to avoid post-procedural hemorrhage in patients with an abnormal coagulative state who need a CVAD. Some limits previously ascribed to PICCs (i.e., low flow rates, difficult central venous pressure monitoring, lack of safety for radio-diagnostic procedures, single-lumen) have delayed their start up in the intensive care units as common practice. Though, the recent development of power-injectable PICCs overcomes these technical limitations and PICCs have started to spread in critical care settings. Two important take-home messages may be drawn from this review. First, the incidence of complications varies depending on venous accesses and healthcare professionals should be aware of the different clinical performance as well as of the different risks

  12. Patterns of transposable element expression and insertion in cancer

    Directory of Open Access Journals (Sweden)

    Evan A Clayton

    2016-11-01

    Full Text Available Human transposable element (TE activity in somatic tissues causes mutations that can contribute to tumorigenesis. Indeed, TE insertion mutations have been implicated in the etiology of a number of different cancer types. Nevertheless, the full extent of somatic TE activity, along with its relationship to tumorigenesis, have yet to be fully explored. Recent developments in bioinformatics software make it possible to analyze TE expression levels and TE insertional activity directly from transcriptome (RNA-seq and whole genome (DNA-seq next-generation sequence data. We applied these new sequence analysis techniques to matched normal and primary tumor patient samples from the Cancer Genome Atlas (TCGA in order to analyze the patterns of TE expression and insertion for three cancer types: breast invasive carcinoma, head and neck squamous cell carcinoma, and lung adenocarcinoma. Our analysis focused on the three most abundant families of active human TEs: Alu, SVA and L1. We found evidence for high levels of somatic TE activity for these three families in normal and cancer samples across diverse tissue types. Abundant transcripts for all three TE families were detected in both normal and cancer tissues along with an average of ~80 unique TE insertions per individual patient/tissue. We observed an increase in L1 transcript expression and L1 insertional activity in primary tumor samples for all three cancer types. Tumor-specific TE insertions are enriched for private mutations, consistent with a potentially causal role in tumorigenesis. We used genome feature analysis to investigate two specific cases of putative cancer-causing TE mutations in further detail. An Alu insertion in an upstream enhancer of the CBL tumor suppressor gene is associated with down-regulation of the gene in a single breast cancer patient, and an L1 insertion in the first exon of the BAALC gene also disrupts its expression in head and neck squamous cell carcinoma. Our results are

  13. Focus on peripherally inserted central catheters in critically ill patients

    Science.gov (United States)

    Cotogni, Paolo; Pittiruti, Mauro

    2014-01-01

    Venous access devices are of pivotal importance for an increasing number of critically ill patients in a variety of disease states and in a variety of clinical settings (emergency, intensive care, surgery) and for different purposes (fluids or drugs infusions, parenteral nutrition, antibiotic therapy, hemodynamic monitoring, procedures of dialysis/apheresis). However, healthcare professionals are commonly worried about the possible consequences that may result using a central venous access device (CVAD) (mainly, bloodstream infections and thrombosis), both peripherally inserted central catheters (PICCs) and centrally inserted central catheters (CICCs). This review aims to discuss indications, insertion techniques, and care of PICCs in critically ill patients. PICCs have many advantages over standard CICCs. First of all, their insertion is easy and safe -due to their placement into peripheral veins of the arm- and the advantage of a central location of catheter tip suitable for all osmolarity and pH solutions. Using the ultrasound-guidance for the PICC insertion, the risk of hemothorax and pneumothorax can be avoided, as well as the possibility of primary malposition is very low. PICC placement is also appropriate to avoid post-procedural hemorrhage in patients with an abnormal coagulative state who need a CVAD. Some limits previously ascribed to PICCs (i.e., low flow rates, difficult central venous pressure monitoring, lack of safety for radio-diagnostic procedures, single-lumen) have delayed their start up in the intensive care units as common practice. Though, the recent development of power-injectable PICCs overcomes these technical limitations and PICCs have started to spread in critical care settings. Two important take-home messages may be drawn from this review. First, the incidence of complications varies depending on venous accesses and healthcare professionals should be aware of the different clinical performance as well as of the different risks

  14. Body of Knowledge (BOK) for Leadless Quad Flat No-Lead/bottom Termination Components (QFN/BTC) Package Trends and Reliability

    Science.gov (United States)

    Ghaffarian, Reza

    2014-01-01

    Bottom terminated components and quad flat no-lead (BTC/QFN) packages have been extensively used by commercial industry for more than a decade. Cost and performance advantages and the closeness of the packages to the boards make them especially unique for radio frequency (RF) applications. A number of high-reliability parts are now available in this style of package configuration. This report presents a summary of literature surveyed and provides a body of knowledge (BOK) gathered on the status of BTC/QFN and their advanced versions of multi-row QFN (MRQFN) packaging technologies. The report provides a comprehensive review of packaging trends and specifications on design, assembly, and reliability. Emphasis is placed on assembly reliability and associated key design and process parameters because they show lower life than standard leaded package assembly under thermal cycling exposures. Inspection of hidden solder joints for assuring quality is challenging and is similar to ball grid arrays (BGAs). Understanding the key BTC/QFN technology trends, applications, processing parameters, workmanship defects, and reliability behavior is important when judicially selecting and narrowing the follow-on packages for evaluation and testing, as well as for the low risk insertion in high-reliability applications.

  15. Certification of packagings: compliance with DOT specification 7A packaging requirements

    Energy Technology Data Exchange (ETDEWEB)

    Edling, D.A.

    1976-10-08

    A study was conducted to determine which of the packagings currently listed in CFR 49 Section 173.395 a.1-5, meet the Specification 7A requirements (CFR 49 Section 173.350). According to DOT HM-111 the present listing of various authorized DOT specifications in Section 173.394 and Section 173.395 (Type A containers) of ICC Tariff No. 27 would be deleted with complete reliance being placed on the use of DOT 7A, Type A general packaging specification. Each user of a Specification 7A package would be required to document and maintain on file for one year a written record of his determination of compliance with the DOT Specification 7A performance requirements. All the specification packagings listed in CFR 49 Section 173.395a.1-5 were tested and shown to meet the Specification 7A criteria; however, in many cases qualifications were placed on their use. Forty-nine specification packagings were tested and shown to meet the DOT Specification 7A performance requirements and since there were several styles of some specific packagings, this amounts to greater than 80 packagings. The extensive testing generally indicated a high degree of containment integrity in the packagings tested and the documentation discussed is a valuable tool for shippers of Type A quantities of radioactive materials. (DLC)

  16. Informed peg-in-hole insertion using optical sensors

    Science.gov (United States)

    Paulos, Eric; Canny, John F.

    1993-08-01

    Peg-in-hole insertion is not only a longstanding problem in robotics but the most common automated mechanical assembly task. In this paper we present a high precision, self-calibrating peg-in-hole insertion strategy using several very simple, inexpensive, and accurate optical sensors. The self-calibrating feature allows us to achieve successful dead-reckoning insertions with tolerances of 25 microns without any accurate initial position information for the robot, pegs, or holes. The program we implemented works for any cylindrical peg, and the sensing steps do not depend on the peg diameter, which the program does not know. The key to the strategy is the use of a fixed sensor to localize both a mobile sensor and the peg, while the mobile sensor localizes the hole. Our strategy is extremely fast, localizing pegs as they are in route to their insertion location without pausing. The result is that insertion times are dominated by the transport time between pick and place operations.

  17. Staphylococcus aureus infections following knee and hip prosthesis insertion procedures.

    Science.gov (United States)

    Arduino, Jean Marie; Kaye, Keith S; Reed, Shelby D; Peter, Senaka A; Sexton, Daniel J; Chen, Luke F; Hardy, N Chantelle; Tong, Steven Yc; Smugar, Steven S; Fowler, Vance G; Anderson, Deverick J

    2015-01-01

    Staphylococcus aureus is the most common and most important pathogen following knee and hip arthroplasty procedures. Understanding the epidemiology of invasive S. aureus infections is important to quantify this serious complication. This nested retrospective cohort analysis included adult patients who had undergone insertion of knee or hip prostheses with clean or clean-contaminated wound class at 11 hospitals between 2003-2006. Invasive S. aureus infections, non-superficial incisional surgical site infections (SSIs) and blood stream infections (BSIs), were prospectively identified following each procedure. Prevalence rates, per 100 procedures, were estimated. 13,719 prosthetic knee (62%) and hip (38%) insertion procedures were performed. Of 92 invasive S. aureus infections identified, SSIs were more common (80%) than SSI and BSI (10%) or BSI alone (10%). The rate of invasive S. aureus infection/100 procedures was 0.57 [95% CI: 0.43-0.73] for knee insertion and 0.83 [95% CI: 0.61-1.08] for hip insertion. More than half (53%) were methicillin-resistant. Median time-to-onset of infection was 34 and 26 days for knee and hip insertion, respectively. Infection was associated with higher National Healthcare Safety Network risk index (p ≤ 0.0001). Post-operative invasive S. aureus infections were rare, but difficult-to-treat methicillin-resistant infections were relatively common. Optimizing preventative efforts may greatly reduce the healthcare burden associated with S. aureus infections.

  18. Seamless lesion insertion in digital mammography: methodology and reader study

    Science.gov (United States)

    Pezeshk, Aria; Petrick, Nicholas; Sahiner, Berkman

    2016-03-01

    Collection of large repositories of clinical images containing verified cancer locations is costly and time consuming due to difficulties associated with both the accumulation of data and establishment of the ground truth. This problem poses a significant challenge to the development of machine learning algorithms that require large amounts of data to properly train and avoid overfitting. In this paper we expand the methods in our previous publications by making several modifications that significantly increase the speed of our insertion algorithms, thereby allowing them to be used for inserting lesions that are much larger in size. These algorithms have been incorporated into an image composition tool that we have made publicly available. This tool allows users to modify or supplement existing datasets by seamlessly inserting a real breast mass or micro-calcification cluster extracted from a source digital mammogram into a different location on another mammogram. We demonstrate examples of the performance of this tool on clinical cases taken from the University of South Florida Digital Database for Screening Mammography (DDSM). Finally, we report the results of a reader study evaluating the realism of inserted lesions compared to clinical lesions. Analysis of the radiologist scores in the study using receiver operating characteristic (ROC) methodology indicates that inserted lesions cannot be reliably distinguished from clinical lesions.

  19. Transposable element insertions have strongly affected human evolution

    Science.gov (United States)

    Britten, Roy J.

    2010-01-01

    Comparison of a full collection of the transposable element (TE) sequences of vertebrates with genome sequences shows that the human genome makes 655 perfect full-length matches. The cause is that the human genome contains many active TEs that have caused TE inserts in relatively recent times. These TE inserts in the human genome are several types of young Alus (AluYa5, AluYb8, AluYc1, etc.). Work in many laboratories has shown that such inserts have many effects including changes in gene expression, increases in recombination, and unequal crossover. The time of these very effective changes in the human lineage genome extends back about 4 million years according to these data and very likely much earlier. Rapid human lineage-specific evolution, including brain size is known to have also occurred in the last few million years. Alu insertions likely underlie rapid human lineage evolution. They are known to have many effects. Examples are listed in which TE sequences have influenced human-specific genes. The proposed model is that the many TE insertions created many potentially effective changes and those selected were responsible for a part of the striking human lineage evolution. The combination of the results of these events that were selected during human lineage evolution was apparently effective in producing a successful and rapidly evolving species. PMID:21041622

  20. Novel prion protein insert mutation associated with prolonged neurodegenerative illness.

    Science.gov (United States)

    Lewis, V; Collins, S; Hill, A F; Boyd, A; McLean, C A; Smith, M; Masters, C L

    2003-05-27

    Mutations in the prion protein gene (PRNP) are found in approximately 13 to 15% of persons classified as dying from a transmissible spongiform encephalopathy. Point and octapeptide repeat insert and deletion mutations are described in the open reading frame (ORF) of PRNP. The authors present a clinicopathologic study of a patient with a family history of a lengthy and progressive neurodegenerative disorder associated with a novel large octapeptide repeat insert mutation. Neuropathologic examination, including immunohistochemistry for the prion protein, was undertaken. The ORF of PRNP was amplified by PCR, cloned, and sequenced. Homogenate of cerebral tissue underwent Western blot analysis for the prion protein before and after proteinase K treatment. The proband died after a 16-year illness commencing at age 29 years. Confident premortem clinical diagnosis was not achieved despite a brain biopsy. Autopsy examination of the brain confirmed a spongiform encephalopathy. Prion protein immunohistochemistry revealed occasional granular deposits in the cerebellar granular layer. The proband was found to harbor a novel PRNP 168 base pair (bp) insert mutation. The authors have identified a novel 168 bp octapeptide repeat insert mutation. Prion protein immunohistochemistry differs from previous cases harboring seven octapeptide repeat and other long insert mutations. Optimization of PRNP analysis, especially PCR conditions, is essential to avoid overlooking this type of mutation and delay the correct molecular genetic diagnosis.

  1. Clinical outcome of narrow diameter implants inserted into allografts

    Directory of Open Access Journals (Sweden)

    Maurizio Franco

    2009-08-01

    Full Text Available OBJECTIVE: Narrow diameter implants (NDI (i.e. diameter <3.75 mm are a potential solution for specific clinical situations, such as reduced interradicular bone, thin alveolar crest and replacement of teeth with small cervical diameter. NDI have been available in clinical practice since the 1990s, but only few studies have analyzed their clinical outcome and no study have investigated NDI inserted in fresh-frozen bone (FFB grafts. Thus, a retrospective study on a series of NDI placed in homologue FFB was designed to evaluate their clinical outcome. MATERIAL AND METHODS: In the period between December 2003 and December 2006, 36 patients (22 females and 14 males, mean age 53 years with FFB grafts were selected and 94 different NDI were inserted. The mean follow-up was 25 months. To evaluate the effect of several host-, surgery-, and implant-related factors, marginal bone loss (MBL was considered an indicator of success rate (SCR. The Kaplan Meier algorithm and Cox regression were used. RESULTS: Only 5 out of 94 implants were lost (i.e. survival rate - SVR 95.7% and no differences were detected among the studied variables. On the contrary, the Cox regression showed that the graft site (i.e. maxilla reduced MBL. CONCLUSIONS: NDI inserted in FFB have a high SVR and SCR similar to those reported in previous studies on regular and NDI inserted in non-grafted jaws. Homologue FFB is a valuable material in the insertion of NDI.

  2. Detection and identification of multiple genetically modified events using DNA insert fingerprinting.

    Science.gov (United States)

    Raymond, Philippe; Gendron, Louis; Khalf, Moustafa; Paul, Sylvianne; Dibley, Kim L; Bhat, Somanath; Xie, Vicki R D; Partis, Lina; Moreau, Marie-Eve; Dollard, Cheryl; Coté, Marie-José; Laberge, Serge; Emslie, Kerry R

    2010-03-01

    Current screening and event-specific polymerase chain reaction (PCR) assays for the detection and identification of genetically modified organisms (GMOs) in samples of unknown composition or for the detection of non-regulated GMOs have limitations, and alternative approaches are required. A transgenic DNA fingerprinting methodology using restriction enzyme digestion, adaptor ligation, and nested PCR was developed where individual GMOs are distinguished by the characteristic fingerprint pattern of the fragments generated. The inter-laboratory reproducibility of the amplified fragment sizes using different capillary electrophoresis platforms was compared, and reproducible patterns were obtained with an average difference in fragment size of 2.4 bp. DNA insert fingerprints for 12 different maize events, including two maize hybrids and one soy event, were generated that reflected the composition of the transgenic DNA constructs. Once produced, the fingerprint profiles were added to a database which can be readily exchanged and shared between laboratories. This approach should facilitate the process of GMO identification and characterization.

  3. SUSTAINABLE PACKAGING SOLUTIONS FOR ORGANIC FRESH BERRIES

    Directory of Open Access Journals (Sweden)

    Elisabeta Elena TĂNASE

    2017-12-01

    Full Text Available Climate changes and particularly global warming are topics carefully treated by specialists already since decades. The most pregnant factor that influences climate change is pollution, namely the high level carbon dioxide emissions. Besides other substances used by the most of the industries (oil, charcoal, fertilizers, etc., plastics are not to be ignored when talking about pollution. Plastic waste affects animals and humans, as well as their habitat. In this respect, food industry engages in preserving the good functioning of the environment by developing and using biodegradable and bio-based resources for food packaging. The aim of this literature review was to identify the optimal sustainable packaging solution used for berries. The results of the study pointed out that the most used environmentally friendly packaging technique is the one that involves modified atmosphere. In terms of packaging materials, the literature is limited when it comes to biodegradable/bio-based solutions. However, active packaging gains popularity among researchers, considering the endless possibilities to include sustainable compounds in a biopolymer based matrix, in order to prolong the shelf-life of berries or fruits in general.

  4. Antimicrobial nanomaterials for food packaging applications

    Directory of Open Access Journals (Sweden)

    Radusin Tanja I.

    2016-01-01

    Full Text Available Food packaging industry presents one of the fastest growing industries nowadays. New trends in this industry, which include reducing food as well as packaging waste, improved preservation of food and prolonged shelf-life together with substitution of petrochemical sources with renewable ones are leading to development of this industrial area in diverse directions. This multidisciplinary challenge is set up both in front of food and material scientists. Nanotechnology is recently answering to these challenges, with different solutions-from improvements in materials properties to active packaging solutions, or both at the same time. Incorporation of nanoparticles into polymer matrix and preparation of hybrid materials is one of the methods of modification of polymer properties. Nano scaled materials with antimicrobial properties can act as active components when added into polymer, thereby leading to prolonged protective function of pristine food packaging material. This paper presents a review in the field of antimicrobial nanomaterials for food packaging in turn of technology, application and regulatory issues.

  5. Advances in Packaging Methods, Processes and Systems

    Directory of Open Access Journals (Sweden)

    Nitaigour Premchand Mahalik

    2014-10-01

    Full Text Available The food processing and packaging industry is becoming a multi-trillion dollar global business. The reason is that the recent increase in incomes in traditionally less economically developed countries has led to a rise in standards of living that includes a significantly higher consumption of packaged foods. As a result, food safety guidelines have been more stringent than ever. At the same time, the number of research and educational institutions—that is, the number of potential researchers and stakeholders—has increased in the recent past. This paper reviews recent developments in food processing and packaging (FPP, keeping in view the aforementioned advancements and bearing in mind that FPP is an interdisciplinary area in that materials, safety, systems, regulation, and supply chains play vital roles. In particular, the review covers processing and packaging principles, standards, interfaces, techniques, methods, and state-of-the-art technologies that are currently in use or in development. Recent advances such as smart packaging, non-destructive inspection methods, printing techniques, application of robotics and machineries, automation architecture, software systems and interfaces are reviewed.

  6. RNA Encapsidation and Packaging in the Phleboviruses

    Directory of Open Access Journals (Sweden)

    Katherine E. Hornak

    2016-07-01

    Full Text Available The Bunyaviridae represents the largest family of segmented RNA viruses, which infect a staggering diversity of plants, animals, and insects. Within the family Bunyaviridae, the Phlebovirus genus includes several important human and animal pathogens, including Rift Valley fever virus (RVFV, severe fever with thrombocytopenia syndrome virus (SFTSV, Uukuniemi virus (UUKV, and the sandfly fever viruses. The phleboviruses have small tripartite RNA genomes that encode a repertoire of 5–7 proteins. These few proteins accomplish the daunting task of recognizing and specifically packaging a tri-segment complement of viral genomic RNA in the midst of an abundance of host components. The critical nucleation events that eventually lead to virion production begin early on in the host cytoplasm as the first strands of nascent viral RNA (vRNA are synthesized. The interaction between the vRNA and the viral nucleocapsid (N protein effectively protects and masks the RNA from the host, and also forms the ribonucleoprotein (RNP architecture that mediates downstream interactions and drives virion formation. Although the mechanism by which all three genomic counterparts are selectively co-packaged is not completely understood, we are beginning to understand the hierarchy of interactions that begins with N-RNA packaging and culminates in RNP packaging into new virus particles. In this review we focus on recent progress that highlights the molecular basis of RNA genome packaging in the phleboviruses.

  7. Chromosomal Insertions in the Lactobacillus casei upp Gene That Are Useful for Vaccine Expression

    Science.gov (United States)

    Song, Bai-fen; Ju, Long-zhu

    2014-01-01

    To develop a stable and marker-free Lactobacillus strain useful for the expression of vaccines, we developed a temperature-sensitive suicide plasmid with expression cassettes containing an HCE promoter, a PgsA anchor, the alpha-toxin gene, and an rrnB T1T2 terminator (PPαT) that uses a 5-fluorouracil (5-FU) counterselectable marker for Lactobacillus casei. Three strains containing the correct PPαT expression cassettes were produced via the selective pressure of 5-FU screening. We confirmed that the upp gene was deleted and that the PPαT expression cassettes were inserted into the upp site of L. casei ATCC 393 by genomic PCR amplification and sequencing. 5-FU resistance in recombinant bacteria could be stably inherited for as long as 40 generations following insertion. However, bacteria containing the integrated DNA grew more slowly than wild-type L. casei. An indirect enzyme-linked immunosorbent assay (ELISA) analysis demonstrated that the alpha-toxin gene was expressed. Also, we visualized expression of the protein on the surface of L. casei cells using laser confocal microscopy. These results taken together demonstrate that these recombinant bacteria should provide a safe tool for effective vaccine production. PMID:24657853

  8. Expanded polyglutamine embedded in the endoplasmic reticulum causes membrane distortion and coincides with Bax insertion

    Energy Technology Data Exchange (ETDEWEB)

    Ueda, Masashi; Li, Shimo; Itoh, Masanori; Wang, Miao-xing; Hayakawa, Miki; Islam, Saiful; Tana; Nakagawa, Kiyomi [Department of Neurobiology, Gifu University Graduate School of Medicine, 1-1 Yanagido, Gifu 501-1194 (Japan); Chen, Huayue [Department of Anatomy, Gifu University Graduate School of Medicine, 1-1 Yanagido, Gifu 501-1194 (Japan); Nakagawa, Toshiyuki, E-mail: tnakagaw@gifu-u.ac.jp [Department of Neurobiology, Gifu University Graduate School of Medicine, 1-1 Yanagido, Gifu 501-1194 (Japan)

    2016-05-27

    The endoplasmic reticulum (ER) is important in various cellular functions, such as secretary and membrane protein biosynthesis, lipid synthesis, and calcium storage. ER stress, including membrane distortion, is associated with many diseases such as Huntington's disease. In particular, nuclear envelope distortion is related to neuronal cell death associated with polyglutamine. However, the mechanism by which polyglutamine causes ER membrane distortion remains unclear. We used electron microscopy, fluorescence protease protection assay, and alkaline treatment to analyze the localization of polyglutamine in cells. We characterized polyglutamine embedded in the ER membrane and noted an effect on morphology, including the dilation of ER luminal space and elongation of ER-mitochondria contact sites, in addition to the distortion of the nuclear envelope. The polyglutamine embedded in the ER membrane was observed at the same time as Bax insertion. These results demonstrated that the ER membrane may be a target of polyglutamine, which triggers cell death through Bax. -- Highlights: •We characterized polyglutamine embedded in the ER membrane. •The polyglutamine embedded in the ER membrane was observed at the same time as Bax insertion. •The ER membrane may be a target of polyglutamine, which triggers cell death.

  9. Stability Studies on Dry Swabs and Wet Mailed Swabs for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in Aptima Assays.

    Science.gov (United States)

    Moncada, Jeanne; Clark, Carey B; Holden, Jeffrey; Hook, Edward W; Gaydos, Charlotte A; Schachter, Julius

    2017-03-01

    The Aptima Combo 2 (AC2) and Aptima CT (ACT) (Hologic Inc., San Diego, CA) are nucleic acid amplification tests (NAATs) that detect Chlamydia trachomatis AC2 also detects Neisseria gonorrhoeae Storage and temperature conditions may impact the utility of NAATs in some settings and screening programs. We evaluated specimen stability for use beyond the Aptima package insert specifications for temperature and duration of storage (between 2°C and 30°C and 60 days, respectively) in two studies: (i) dry C. trachomatis-seeded swabs were used with ACT after storage at 4°C, 23°C, or 36°C for up to 84 days and (ii) swabs seeded with C. trachomatis and N. gonorrhoeae and then placed in transport medium were tested with AC2, after being mailed via the U.S. Postal Service to three different sites. Prolonged storage of samples had no effect, and samples stored at 4°C, 23°C, and 36°C for up to 84 days yielded comparable ACT positivities, although there was a drop in signal intensity for virtually all specimens under all storage/shipping conditions after day 21. In the mailing study, 80%, 52% and 29% of seeded swabs were exposed to temperatures of >30°C during three rounds in transit, and 2% reached temperatures of >40°C. No evidence of signal degradation in the AC2 assay for detection of C. trachomatis or N. gonorrhoeae was observed, although some mailed swabs took more than 5 weeks to reach the laboratory site. These two studies support the potential use of swabs at temperatures above 36°C and storage beyond 60 days and provide confidence regarding this commercially available NAAT for testing of specimens after mailing. Copyright © 2017 American Society for Microbiology.

  10. Packaging wastes management; Gestion integral de los residuos de envases

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Ramos, M.

    1996-12-01

    Packaging, having fulfilled their function, become waste and joint the flow of resure we generate every day. Packaging waste is a usable secondary raw material, provided that a suitable integrated management strategy is devised. This article highlights the Integrated Management Strategic Plan for Packaging Waste, following the priority guidelines established by the Community Directives on waste management: Reduction, re-use, Recycling, Energy Recovery and Final Elimination, and the European Directive 94/62/CE about packaging and packaging waste. (Author)

  11. Performance of U3Si2 Fuel in a Reactivity Insertion Accident

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Lap Y.; Cuadra, Arantxa; Todosow, Michael; Gamble, Kyle A.; Medvedev, Pavel G.

    2016-04-01

    In this study we examined the performance of the U3Si2 fuel cladded with Zircaloy (Zr) in a reactivity insertion accident (RIA) in a PWR core. The power excursion as a result of a $1 reactivity insertion was calculated by a TRACE PWR plant model using point-kinetics, for alternative cores with UO2 and U3Si2 fuel assemblies. The point-kinetics parameters (feedback coefficients, prompt-neutron lifetime and group constants for six delayed-neutron groups) were obtained from beginning-of-cycle equilibrium full core calculations with PARCS. In the PARCS core calculations, the few-group parameters were developed utilizing the TRITON/NEWT tools in the SCALE package. In order to assess the fuel response in finer detail (e.g. the maximum fuel temperature) the power shape and thermal boundary conditions from the TRACE/PARCS calculations were used to drive a BISON model of a fuel pin with U3Si2 and UO2 respectively. For a $1 reactivity transient both TRACE and BISON predicted a higher maximum fuel temperature for the UO2 fuel than the U3Si2 fuel. Furthermore, BISON is noted to calculate a narrower gap and a higher gap heat transfer coefficient than TRACE. This resulted in BISON predicting consistently lower fuel temperatures than TRACE. This study also provides a systematic comparison between TRACE and BISON using consistent transient boundary conditions. The TRACE analysis of the RIA only reflects the core-wide response in power. A refinement to the analysis would be to predict the local peaking in a three-dimensional core as a result of control rod ejection.

  12. The strategic use of inserts in the Brazilian presidential elections

    Directory of Open Access Journals (Sweden)

    Felipe Borba

    2012-01-01

    Full Text Available The aim of this article is to analyze the communication strategies of presidential candidates during the elections held in 2006 and 2010. The focus is on the strategic component of electoral inserts and the methodology consists of investigating how candidates choose to distribute these inserts in the programming of television networks. The results indicate that the candidates pursue different strategies influenced basically by three variables: electoral legislation, their standing in polls and the difference of resources available. In parallel, the article debates the role of the regulation of electoral advertising and how this set of rules influences the level of information of campaigns, the occurrence of attacks, and party strategies. Overall, 2,993 electoral inserts were examined.

  13. Indentation and needle insertion properties of the human eye

    Science.gov (United States)

    Matthews, A; Hutnik, C; Hill, K; Newson, T; Chan, T; Campbell, G

    2014-01-01

    Purpose Characterization of the biomechanical properties of the human eye has a number of potential utilities. One novel purpose is to provide the basis for development of suitable tissue-mimicking material. The purpose of this study was to determine the indentation and needle insertion characteristics on human eye globes and tissue strips. Methods An indenter assessed the elastic response of human eye globes and tissue strips under increasing compressive loads. Needle insertion determined the force (N) needed to penetrate various areas of the eye wall. Results The results demonstrated that globes underwent slightly greater indentation at the midline than at the central cornea, and corneal strips indented twofold more than scleral strips, although neither difference was significant (P=0.400 and P=0.100, respectively). Significant differences were observed among various areas of needle insertion (Peye construct with potential utility as a model for use in ophthalmology research and surgical teaching. PMID:24810571

  14. Modeling of Porous Insertion Electrodes with Liquid Electrolyte

    DEFF Research Database (Denmark)

    West, Keld; Jacobsen, Torben; Atlung, Sven

    1982-01-01

    The dynamics of porous insertion electrodes during charge or discharge is described by a simplified mathematicalmodel, accounting for the coupled transport in electrode and electrolyte phases. A numerical method to evaluate theresponse of this model to either controlled potential or controlled...... current is outlined, and numerical results for thedischarge of a porous TiS2-electrode in an idealized organic electrolyte are presented. It is demonstrated how electrolyte depletion is the principal limiting factor in the capacity obtained during discharge of this electrode system. Thisdepletion...... is a consequence of the mobility of the ions not inserted, hence the performance of this type of electrode isoptimized by choosing electrolytes with transport number as close to unity as possible for the inserted ion....

  15. Inserts and omissions in the Calvinist Catechism printed in 1648

    Directory of Open Access Journals (Sweden)

    Enikő Pál

    2015-07-01

    Full Text Available The present paper aims to contribute to researches on old Romanian translations, examined from the perspective of translation studies. In this respect, the pursued objective is to set up a typology of inserts and omissions found in the Romanian translation of the catechism printed in 1648, taking into account the main causes which generated them. Thus, applying the methods and tools characteristic for comparative analysis, we shall present the contexts in which the Romanian translation deviates from one of its sources or from both of them, focusing on the reasons which could have determined the translator’s options to insert or, on the contrary, to omit certain linguistic units. In the text chosen for analysis, the status of inserts and omissions varies from case to case, but, taken all together, they may be grouped into two main classes reflecting two different levels of translation achievement: the level of creation and the level of imitation respectively.

  16. Polyglutamine expansion in huntingtin increases its insertion into lipid bilayers.

    Science.gov (United States)

    Kegel, Kimberly B; Schewkunow, Vitali; Sapp, Ellen; Masso, Nicholas; Wanker, Erich E; DiFiglia, Marian; Goldmann, Wolfgang H

    2009-09-25

    An expanded polyglutamine (Q) tract (>37Q) in huntingtin (htt) causes Huntington disease. Htt associates with membranes and polyglutamine expansion in htt may alter membrane function in Huntington disease through a mechanism that is not known. Here we used differential scanning calorimetry to examine the effects of polyQ expansion in htt on its insertion into lipid bilayers. We prepared synthetic lipid vesicles composed of phosphatidylcholine and phosphatidylethanolamine and tested interactions of htt amino acids 1-89 with 20Q, 32Q or 53Q with the vesicles. GST-htt1-89 with 53Q inserted into synthetic lipid vesicles significantly more than GST-htt1-89 with 20Q or 32Q. We speculate that by inserting more into cell membranes, mutant huntingtin could increase disorder within the lipid bilayer and thereby disturb cellular membrane function.

  17. Reliable communication over non-binary insertion/deletion channels

    CERN Document Server

    Yazdani, Raman

    2012-01-01

    We consider the problem of reliable communication over non-binary insertion/deletion channels where symbols are randomly deleted from or inserted in the transmitted sequence and all symbols are corrupted by additive white Gaussian noise. To this end, we utilize the inherent redundancy achievable in non-binary symbol sets by first expanding the symbol set and then allocating part of the bits associated with each symbol to watermark symbols. The watermark sequence, known at the receiver, is then used by a forward-backward algorithm to provide soft information for an outer code which decodes the transmitted sequence. Through numerical results and discussions, we evaluate the performance of the proposed solution and show that it leads to significant system ability to detect and correct insertions/deletions. We also provide estimates of the maximum achievable information rates of the system, compare them with the available bounds, and construct practical codes capable of approaching these limits.

  18. Insertion of liquid crystal molecules into hydrocarbon monolayers

    Energy Technology Data Exchange (ETDEWEB)

    Popov, Piotr, E-mail: ppopov@kent.edu; Mann, Elizabeth K. [Department of Physics, Kent State University, Kent, Ohio 44242 (United States); Lacks, Daniel J. [Department of Chemical Engineering, Case Western Reserve University, Cleveland, Ohio 44106 (United States); Jákli, Antal [Liquid Crystal Institute, Kent State University, Kent, Ohio 44242-0001 (United States)

    2014-08-07

    Atomistic molecular dynamics simulations were carried out to investigate the molecular mechanisms of vertical surface alignment of liquid crystals. We study the insertion of nCB (4-Cyano-4{sup ′}-n-biphenyl) molecules with n = 0,…,6 into a bent-core liquid crystal monolayer that was recently found to provide good vertical alignment for liquid crystals. The results suggest a complex-free energy landscape for the liquid crystal within the layer. The preferred insertion direction of the nCB molecules (core or tail first) varies with n, which can be explained by entropic considerations. The role of the dipole moments was found to be negligible. As vertical alignment is the leading form of present day liquid crystal displays (LCD), these results will help guide improvement of the LCD technology, as well as lend insight into the more general problem of insertion of biological and other molecules into lipid and surfactant layers.

  19. Synchronized monochromator and insertion device energy scans at SLS

    Science.gov (United States)

    Krempaský, J.; Flechsig, U.; Korhonen, T.; Zimoch, D.; Quitmann, Ch.; Nolting, F.

    2010-06-01

    Synchronous monochromator and insertion device energy scans were implemented at the Surfaces/Interfaces:Microscopy (SIM) beamline in order to provide the users fast X-ray magnetic dichroism studies (XMCD). A simple software control scheme is proposed based on a fast monochromator run-time energy readback which quickly updates the insertion device requested energy during an on-the-fly X-ray absorption scan (XAS). In this scheme the Plain Grating Monochromator (PGM) motion control, being much slower compared with the insertion device (APPLE-II type undulator), acts as a "master" controlling the undulator "slave" energy position. This master-slave software implementation exploits EPICS distributed device control over computer network and allows for a quasi-synchronous motion control combined with data acquisition needed for the XAS or XMCD experiment.

  20. An RNA Domain Imparts Specificity and Selectivity to a Viral DNA Packaging Motor

    Science.gov (United States)

    Zhao, Wei; Jardine, Paul J.

    2015-01-01

    ABSTRACT During assembly, double-stranded DNA viruses, including bacteriophages and herpesviruses, utilize a powerful molecular motor to package their genomic DNA into a preformed viral capsid. An integral component of the packaging motor in the Bacillus subtilis bacteriophage ϕ29 is a viral genome-encoded pentameric ring of RNA (prohead RNA [pRNA]). pRNA is a 174-base transcript comprised of two domains, domains I and II. Early studies initially isolated a 120-base form (domain I only) that retains high biological activity in vitro; hence, no function could be assigned to domain II. Here we define a role for this domain in the packaging process. DNA packaging using restriction digests of ϕ29 DNA showed that motors with the 174-base pRNA supported the correct polarity of DNA packaging, selectively packaging the DNA left end. In contrast, motors containing the 120-base pRNA had compromised specificity, packaging both left- and right-end fragments. The presence of domain II also provides selectivity in competition assays with genomes from related phages. Furthermore, motors with the 174-base pRNA were restrictive, in that they packaged only one DNA fragment into the head, whereas motors with the 120-base pRNA packaged several fragments into the head, indicating multiple initiation events. These results show that domain II imparts specificity and stringency to the motor during the packaging initiation events that precede DNA translocation. Heteromeric rings of pRNA demonstrated that one or two copies of domain II were sufficient to impart this selectivity/stringency. Although ϕ29 differs from other double-stranded DNA phages in having an RNA motor component, the function provided by pRNA is carried on the motor protein components in other phages. IMPORTANCE During virus assembly, genome packaging involves the delivery of newly synthesized viral nucleic acid into a protein shell. In the double-stranded DNA phages and herpesviruses, this is accomplished by a powerful