WorldWideScience

Sample records for aseptic prosthesis loosening

  1. Combined bone scintigraphy with 99mTc-MDP and 99mTc-ciprofloxacin in differentiation of hip and knee prosthesis aseptic loosening and infection: A preliminary study

    Directory of Open Access Journals (Sweden)

    Pucar Dragan

    2017-01-01

    Full Text Available Background/Aim. Although the number of new primary implantation of hip and knee prostheses every year increases, the rate of failed arthroplasty is nearly the same. The main question is whether it is an aseptic instability or instability caused by infection. The aim of this preliminary study was an attempt with combined 99mTc-ciprofloxacin and 99mTc-methylene diphosphonate (MDP bone scintigraphy to improve diagnostic accuracy in the differentiation of hip and knee prosthesis aseptic loosening and periprosthetic joint infection. Methods. Inclusion criteria of patients for this study were based on suspected periprosthetic joint infection: painful prosthetic joint, restricted joint movements and increased value of erythrocyte sedimentation rate or levels of C-reactive protein. We examined 20 patients with implanted 14 hip and 6 knee prosthesis. All patients also underwent plain radiography of suspected joint. In all patients, three-phase 99mTc-MDP bone scintigraphy was performed. Three to five days after the bone scan, we performed scintigraphy using 99mTc-ciprofloxacin with the calculation of accumulation index. Periprosthetic joint infection was confirmed on the basis of microbiological findings. Results. Periprosthetic joint infection was confirmed in fourteen of twenty observed joints, in five of them the aseptic loosening was present and in one patient’s symptoms were not related to the prosthesis (poor biomechanics of prosthetic joints caused by weaknesses of muscle. Estimated sensitivity/specificity for 99mTc-MDP bone scintigraphy alone were 100/17%; for 99mTc-ciprofloxacin scintigraphy were 85,7/100%. Sensitivity and specificity were 92,3% and 83,3%, respectively for results obtained with combined assessment by both methods. Our study confirmed the high negative predictive value of 99mTc-MDP bone scan. The negative result of bone scan virtually excludes the possibility of periprosthetic infection. On the other hand, positive findings of

  2. Correlation of quantitative histopathological morphology and quantitative radiological analysis during aseptic loosening of hip endoprostheses.

    Science.gov (United States)

    Bertz, S; Kriegsmann, J; Eckardt, A; Delank, K-S; Drees, P; Hansen, T; Otto, M

    2006-01-01

    Aseptic hip prosthesis loosening is the most important long-term complication in total hip arthroplasty. Polyethylene (PE) wear is the dominant etiologic factor in aseptic loosening, which together with other factors induces mechanisms resulting in bone loss, and finally in implant loosening. The single-shot radiograph analysis (EBRA, abbreviation for the German term "Einzel-Bild-Röntgenanalyse") is a computerized method for early radiological prediction of aseptic loosening. In this study, EBRA parameters were correlated with histomorphological parameters of the periprosthetic membrane. Periprosthetic membranes obtained from 19 patients during revision surgery of loosened ABG I-type total hip pros-theses were analyzed histologically and morphometrically. The pre-existing EBRA parameters, the thickness of the PE debris lay-er and the dimension of inclination and anteversion, were compared with the density of macrophages and giant cells. Addi-tionally, the semiquantitatively determined density of lymphocytes, plasma cells, giant cells and the size of the necrotic areas were correlated with the EBRA results. All periprosthetic membranes were classified as debris-induced type membranes. We found a positive correlation between the number of giant cells and the thickness of the PE debris layer. There was no significant correlation between the number of macrophages or all semiquantitative parameters and EBRA parameters. The number of giant cells decreased with implant duration. The morphometrically measured number of foreign body giant cells more closely reflects the results of the EBRA. The semiquantitative estimation of giant cell density could not substitute for the morphometrical analysis. The density of macrophages, lymphocytes, plasma cells and the size of necrotic areas did not correlate with the EBRA parameters, indicating that there is no correlation with aseptic loosening.

  3. Aseptic loosening of the femoral implant after cemented total hip arthroplasty in dogs: 11 cases in 10 dogs (1991-1995)

    International Nuclear Information System (INIS)

    Edwards, M.R.; Egger, E.L.; Schwarz, P.D.

    1997-01-01

    Objective-To determine clinical signs, radiographic findings, results of surgical management, and potential causes of aseptic loosening of the femoral implant (ALFI) in dogs that have undergone cemented total hip arthroplasty (THA). Design-Retrospective study. Animals-11 cases of ALFI in 10 dogs. Procedure-Medical records of all dogs undergoing THA revision surgery were reviewed. Only dogs with ALFI were included. The prosthesis and cement were removed by creating a longitudinal osteotomy of the cranial femoral cortex. Postoperative radiographs of all dogs that underwent THA during the study period were reviewed. Results-The most common clinical sign was intermittent, subtle. or non-weight-bearing lameness. On radiographs obtained after THA, contact of the distal stem tip with cortical endosteum was evident in all dogs. Radiographic changes at the time of diagnosis of ALFI included asymmetric periosteal reaction along the femoral diaphysis, radiolucent lines between the prosthesis and cement, altered implant position, and femoral fracture. Surgical revision yielded good or excellent results in 9 cases. In 1 dog. the implant became infected; in another, aseptic loosening recurred. Aseptic loosening was significantly more common in dogs in which there was contact between the distal stem tip and cortical endosteum than in dogs in which there was no contact. Clinical Implications-ALFI is an uncommon, but important, complication of THA, and radiography is warranted in dogs with clinical signs of ALFI. Initial centering of the prosthetic stem within the femoral shaft may reduce the incidence of ALFI

  4. [Early aseptic loosening of the CF 30 femoral stem].

    Science.gov (United States)

    Kovanda, M; Havlícek, V; Hudec, J

    2007-02-01

    The CF 30 stem in combination with a cementless acetabulum was used at the First Department of Orthopedic Surgery in Brno in the years 1994 to 1995. From the second year following implantation, aseptic stem loosening was recorded. In order to find explanation of this early loosening, the authors, in cooperation with the Institute of Solid Mechanics, Mechatronics and Biomechanics, carried out the stress-strain analysis in a model system. Eighty patients (31 men and 49 women) received a cemented CF30 femoral component in 1994. Of them, 16 patients underwent revision arthroplasty, three died of causes unrelated to the surgery, and four were lost to follow-up. The final clinical and radiographic check-up was carried out in 2001. The results of a comprehensive examination were available in 57 patients with a CF30 stem. The patients were evaluated on the basis of the Harris hip score and anteroposterior radiographs of the hip. X-ray films obtained immediately after surgery and those taken at regular intervals during follow-up were compared. The following characteristics were noted: translucent lines in individual zones along the stem at the cement-bone interface; osteolysis, i. e., non-linear translucent areas, at least 5 mm long, at the cement-bone interface; and subsidence of the femoral component, i. e., migration of the stem distal to the tip of the greater trochanter. The CF 30 stem survival curve showed that aseptic stem loosening occurred from post-implantation year 2, and increased during the following years. At 6 years and 6 months, a total of 16 patients underwent revision surgery, involving reimplantation in 14 and implant removal in 2 patients. Potential causes of aseptic loosening: Polyethylene wear.However, no acetabular loosening was found in this group, although acetabular components are reported to become loose more often than femoral components. By comparison of the stem survival curves for Poldi and CF 30 stems it appeared that, at 6 years and 6 months

  5. Diabetes Mellitus and Hyperglycemia and the Risk of Aseptic Loosening in Total Joint Arthroplasty.

    Science.gov (United States)

    Maradit Kremers, Hilal; Schleck, Cathy D; Lewallen, Eric A; Larson, Dirk R; Van Wijnen, Andre J; Lewallen, David G

    2017-09-01

    It is unknown to what extent diabetes mellitus modifies the long-term risk of aseptic loosening in total hip arthroplasty (THA) and total knee arthroplasty (TKA). We examined the association between diabetes mellitus, perioperative hyperglycemia, and the likelihood of revisions for aseptic loosening. We studied 16,085 primary THA and TKA procedures performed at a large tertiary care hospital between 2002 and 2009. All blood glucose values around the time of surgery (within 1 week) were retrieved. Subsequent revision surgeries and the reasons for revision were ascertained through the institutional joint registry. Multivariate Cox models were used to estimate the hazard ratios (HRs) and 95% confidence intervals (CIs) for aseptic loosening associated with diabetes mellitus and hyperglycemia adjusting for age, gender, body mass index, and surgery type. A total of 2911 (18%) surgeries had a diagnosis of diabetes mellitus at the time of surgery. Glucose testing was performed at least once in 7055 (44%) procedures within ±1 week of surgery. Although diabetic patients did not experience a higher risk of revision for aseptic loosening (HR, 0.87; 95% CI, 0.55-1.38), higher preoperative glucose values on the day before surgery were significantly associated with both the overall risk of revisions (HR, 2.80; 95% CI, 1.00-7.85) and revisions for aseptic loosening (HR, 4.95; 95% CI, 1.26-19.54). High preoperative hyperglycemia is a potential risk factor for aseptic loosening in THA and TKA. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Pinning down loosened prostheses : imaging and planning of percutaneous hip refixation

    NARCIS (Netherlands)

    Malan, Daniel Francois

    2015-01-01

    This thesis examines how computer software can be used to analyse medical images of an aseptically loosening hip prosthesis, and subsequently to plan and guide a minimally invasive cement injection procedure to stabilize the prosthesis. We addressed the detection and measurement of periprosthetic

  7. Analysis of 18 F-FDG uptake patterns in PET for diagnosis of septic and aseptic loosening after total hip arthroplasty

    International Nuclear Information System (INIS)

    Cremerius, U.; Niethard, F.U.; Mumme, T.; Reinartz, P.; Wirtz, D.; Buell, U.

    2003-01-01

    Aim: Identification of typical patterns for fluorodeoxyglucose (FDG) uptake in positron emission tomography (PET) to detect aseptic loosening of hip prosthesis (acetabular and/or femoral component) and prosthetic infection. Methods: 18 patients with painful hip prosthesis underwent PET using a dedicated full ring scanner after application of 200-300 MBq FDG. The interface between bone and surrounding soft tissue or bone as displayed on coronal slices was divided into 12 segments in accordance with the classifications of Delee and Gruen. FDG uptake in each of the segments was scored (0-3) by two independent observers. Intraoperative findings were regarded as the gold standard. Results: After surgical revision 14 acetabular components and 9 femoral components were found to be loose and prosthetic infection was present in 7 prostheses. Loosening of the acetabular component was correlated to enhanced uptake in the middle of the acetabular interface, while loosening of the femoral component was correlated to enhanced uptake in the proximal and middle segment of the lateral femoral interface and the proximal segment of the medial femoral interface. A similar pattern was found in prosthetic infection with high uptake along the middle portion of the lateral femoral interface. In 6 of 7 infected prostheses loosening of the acetabular and of the femoral component was present. Taking the typical uptake patterns as criteria for loosening and grade 3 uptake as an additional criterion for septic loosening the accuracy of PET imaging in the detection of loosening of the acetabular or the femoral component and of prosthetic infection was 72, 78 and 89%, respectively. Conclusion: This pilot study presents FDG-PET as a promising diagnostic tool for patients with painful hip prostheses. Its clinical value should be evaluated in a larger patient population. (orig.) [de

  8. Association between Apoptotis and CD4+/CD8+ T-Lymphocyte Ratio in Aseptic Loosening after Total Hip Replacement

    Science.gov (United States)

    Landgraeber, Stefan; von Knoch, Marius; Löer, Franz; Brankamp, Jochen; Tsokos, Michael; Grabellus, Florian; Schmid, Kurt Werner; Totsch, Martin

    2009-01-01

    Particle-induced osteolysis is a major cause of aseptic loosening after total joint replacement. While the osteolytic cascade initiated by cytokine release from macrophages has been studied extensively, the involvement of T-lymphocytes in this context is controversial and has been addressed by only a few authors. In a former study we detected that the quantity of T-lymphocytes may be influenced by apoptosis in patients with aseptic loosening. In this study we intended to find out more details about the apoptosis-induced shifting of the T-cell number. We focused our interest on the CD4+ and CD8+ T-cells and their relative ratio. Caspase-3 cleaved was evaluated immunohistochemically to detect apoptotic T-cells in capsules and interface membranes from patients with aseptic hip implant loosening and a varying degree of caspase-3 cleaved expression in CD4+ and CD8+ T-lymphocytes was detected. Moreover, a relationship between the intensity of the apoptotic reactions and the radiological extent of osteolysis was observed. The number of CD4+ cells was decreased in the presence of strong apoptotic reactions, respectively extensive osteolysis, while CD8+ cells were affected to a much lower degree. Thus, the CD4+/CD8+ ratio changed from 1.0 in cases with only small areas of periprosthetic osteolysis and minimally intense apoptosis to 0.33 in cases with large areas of osteolysis. This may suggest a causal relationship between the apoptosis-induced shift in the CD4+/CD8+ ratio and the osteolysis respectively aseptic loosening. It is possible that these findings may lead to a new understanding of particle-induced osteolysis. PMID:19214244

  9. Effects of Prosthesis Stem Tapers on Stress Distribution of Cemented Hip Arthroplasty

    International Nuclear Information System (INIS)

    Abdullah, Abdul Halim; Nor, Mohd Asri Mohd; Saman, Alias Mohd; Tamin, Mohd Nasir; Kadir, Mohammed Rafiq Abdul

    2010-01-01

    Aseptic loosening effects are critical issues in encouraging long term stability of cemented hip arthroplasty. Stress shielding is believed to be an important factor that contributes to the aseptic loosening problems. The numerous changes in the prosthesis stem design are intended to minimize the stress shielding and aseptic loosening problems and to improve the long term performance of the implants. In this study, the stress distribution in cemented hip arthroplasty is established using finite element method. The taper of the prosthesis is designed to be 3 deg. at anterior/posterior, 3 deg. at medial/lateral and 10 deg. from wide lateral to narrow medial. Major muscle loads and contact forces are simulated for walking (toe-off phase) and stair climbing load cases. Effects of prosthesis stem tapers on the resulting stress distribution are investigated. Results show that compressive stress dominates in the medial plane while tensile stress in the lateral plane of the femur. The corresponding stress levels of intact femur for walking and stair-climbing load cases are 22 and 29 MPa, respectively. The magnitude of Tresca stress for the THA femur in stair-climbing load case remains higher in the region of 85 MPa while the walking load case induces around 40 MPa. The stress range in the straight and single taper stem prosthesis is lower than 260 MPa, while localized Tresca stress is in the order of the yield strength of Ti-6Al-4V alloy for double and triple taper stem design.

  10. Developmental dysplasia of the hip, age, BMI, place of residence and tobacco abuse increase the odds of aseptic loosening in Chinese patients.

    Directory of Open Access Journals (Sweden)

    Chuanlong Wu

    Full Text Available PURPOSE: The purpose of this hospital-based case-control study was to evaluate the patient-related risk factors for aseptic loosening after total hip arthroplasty (THA and total knee arthroplasty (TKA in Chinese patients. METHODS: From January 2000 to December 2012, 67 patients undergoing THA and TKA who developed aseptic loosening were detected as case subjects and 336 patients without aseptic loosening, matched by the year of index surgery and type of surgery, were selected as controls. Conditional logistic regression was used to compute odds ratios (ORs and 95% confidence intervals (CIs. RESULTS: The demographic factors and comorbid conditions associated with a risk-adjusted increase in aseptic loosening (in decreasing order of significance were a rural place of residence (OR = 2.28; 95% CI: 1.21-4.30; p = 0.011, body mass index (BMI ≥ 28 kg/m(2 (vs. 18.5-28 kg/m(2 (OR = 2.29; 95% CI: 1.19-4.41; p = 0.013, developmental dysplasia of the hip (DDH (OR = 2.91; 95% CI: 1.11-7.66; p = 0.030, tobacco abuse (OR = 2.88; 95% CI: 1.05-7.89; p = 0.039, and age <45 years (vs. 45-65 years (OR = 2.63; 95% CI: 1.01-6.80; p = 0.047. CONCLUSIONS: Patients aged <45 years and those with a BMI of ≥ 28 kg/m(2, a preoperative diagnosis of DDH, history of tobacco abuse, or living in rural areas are at increased risk for aseptic loosening after THA and TKA in Chinese population. Additional systematic large-scale studies are needed to verify these results.

  11. Strontium-doped calcium polyphosphate/ultrahigh molecular weight polyethylene composites: A new class of artificial joint components with enhanced biological efficacy to aseptic loosening

    International Nuclear Information System (INIS)

    Gu, Zhipeng; Huang, Bingxue; Li, Yiwen; Tian, Meng; Li, Li; Yu, Xixun

    2016-01-01

    To enhance implant stability and prolong the service life of artificial joint component, a new approach was proposed to improve the wear resistance of artificial joint component and endow artificial joint component with the biological efficacy of resistance to aseptic loosening. Strontium calcium polyphosphate (SCPP) were interfused in ultrahigh molecular weight polyethylene (UHMWPE) by a combination of liquid nitrogen ball-milling and flat-panel curing process to prepare the SCPP/UHMWPE composites. The micro-structure, mechanical characterization, tribological characterization and bioactivities of various SCPP/UHMWPE composites were investigated. The results suggested that this method could statistically improve the wear resistance of UHMWPE resulting from a good SCPP particle dispersion. Moreover, it is also observed that the SCPP/UHMWPE composites-wear particles could promote the production of OPG by osteoblasts and decrease the production of RANKL by osteoblasts, and then increase the OPG/RANKL ratio. This indicated that the SCPP/UHMWPE composites had potential efficacy to prevent and treat aseptic loosening. Above all, the SCPP/UHMWPE composites with a suitable SCPP content would be the promising materials for fabricating artificial joint component with ability to resist aseptic loosening. - Highlights: • SCPP/UHMWPE composites could enhance biological efficacy of resistance to aseptic loosening. • SCPP would improve biological efficacy with a few sacrifice of wear resistance. • The results might provide a promising wear-resistant material for fabricating acetabular cup.

  12. Strontium-doped calcium polyphosphate/ultrahigh molecular weight polyethylene composites: A new class of artificial joint components with enhanced biological efficacy to aseptic loosening

    Energy Technology Data Exchange (ETDEWEB)

    Gu, Zhipeng [College of Polymer Science and Engineering, Sichuan University, Chengdu 610065 (China); Department of Neurosurgery, West China Hospital, Sichuan University, Chengdu 610041 (China); Huang, Bingxue; Li, Yiwen [College of Polymer Science and Engineering, Sichuan University, Chengdu 610065 (China); Tian, Meng [Department of Neurosurgery, West China Hospital, Sichuan University, Chengdu 610041 (China); Li, Li [Department of Oncology, the 452 Hospital of Chinese PLA, Chengdu 610021 (China); Yu, Xixun, E-mail: yuxixun@163.com [College of Polymer Science and Engineering, Sichuan University, Chengdu 610065 (China)

    2016-04-01

    To enhance implant stability and prolong the service life of artificial joint component, a new approach was proposed to improve the wear resistance of artificial joint component and endow artificial joint component with the biological efficacy of resistance to aseptic loosening. Strontium calcium polyphosphate (SCPP) were interfused in ultrahigh molecular weight polyethylene (UHMWPE) by a combination of liquid nitrogen ball-milling and flat-panel curing process to prepare the SCPP/UHMWPE composites. The micro-structure, mechanical characterization, tribological characterization and bioactivities of various SCPP/UHMWPE composites were investigated. The results suggested that this method could statistically improve the wear resistance of UHMWPE resulting from a good SCPP particle dispersion. Moreover, it is also observed that the SCPP/UHMWPE composites-wear particles could promote the production of OPG by osteoblasts and decrease the production of RANKL by osteoblasts, and then increase the OPG/RANKL ratio. This indicated that the SCPP/UHMWPE composites had potential efficacy to prevent and treat aseptic loosening. Above all, the SCPP/UHMWPE composites with a suitable SCPP content would be the promising materials for fabricating artificial joint component with ability to resist aseptic loosening. - Highlights: • SCPP/UHMWPE composites could enhance biological efficacy of resistance to aseptic loosening. • SCPP would improve biological efficacy with a few sacrifice of wear resistance. • The results might provide a promising wear-resistant material for fabricating acetabular cup.

  13. Mitigated infection in so called aseptic loosening of the total endoprosthesis of the big joints

    OpenAIRE

    Koudela, Karel

    2008-01-01

    The theme of the work is infection in the aseptic loosening of total joint replacement of large joints. Thesis topic is very timely, since inflammatory complications accompanying large joint arthroplasty is one of the causes of failure of total joint replacement and subsequent revision surgery represents a major problem of health, social and economic. PhD thesis summarizes the known aspects of this issue.

  14. Mechanical instability and titanium particles induce similar transcriptomic changes in a rat model for periprosthetic osteolysis and aseptic loosening

    Directory of Open Access Journals (Sweden)

    Mehdi Amirhosseini

    2017-12-01

    Full Text Available Wear debris particles released from prosthetic bearing surfaces and mechanical instability of implants are two main causes of periprosthetic osteolysis. While particle-induced loosening has been studied extensively, mechanisms through which mechanical factors lead to implant loosening have been less investigated. This study compares the transcriptional profiles associated with osteolysis in a rat model for aseptic loosening, induced by either mechanical instability or titanium particles. Rats were exposed to mechanical instability or titanium particles. After 15 min, 3, 48 or 120 h from start of the stimulation, gene expression changes in periprosthetic bone tissue was determined by microarray analysis. Microarray data were analyzed by PANTHER Gene List Analysis tool and Ingenuity Pathway Analysis (IPA. Both types of osteolytic stimulation led to gene regulation in comparison to unstimulated controls after 3, 48 or 120 h. However, when mechanical instability was compared to titanium particles, no gene showed a statistically significant difference (fold change ≥ ±1.5 and adjusted p-value ≤ 0.05 at any time point. There was a remarkable similarity in numbers and functional classification of regulated genes. Pathway analysis showed several inflammatory pathways activated by both stimuli, including Acute Phase Response signaling, IL-6 signaling and Oncostatin M signaling. Quantitative PCR confirmed the changes in expression of key genes involved in osteolysis observed by global transcriptomics. Inflammatory mediators including interleukin (IL-6, IL-1β, chemokine (C-C motif ligand (CCL2, prostaglandin-endoperoxide synthase (Ptgs2 and leukemia inhibitory factor (LIF showed strong upregulation, as assessed by both microarray and qPCR. By investigating genome-wide expression changes we show that, despite the different nature of mechanical implant instability and titanium particles, osteolysis seems to be induced through similar biological

  15. Differentiation between peri-prosthetic infection and aseptic loosening using quantitative analysis of triphasic 99Tcm-MDP bone scintigraphy

    International Nuclear Information System (INIS)

    Li Xinxin; Zhang Yanyan; Zhang Weifang; Mao Yuan; Zhao Meixin

    2013-01-01

    Objective: To differentiate between peri-prosthetic infection and aseptic loosening using quantitative analysis of triphasic bone scintigraphy. Methods: Twenty-eight patients (9 males, 19 females; mean age 67.5 years, range 49-80 years) with recurrent joint pain after arthroplasty were retrospectively assessed. All patients underwent triphasic bone scintigraphy. ROI of each joint was drawn and the ratios of affected to unaffected side were calculated. The ratios of blood flow phase, blood pool phase, static phase, C-reactive protein (CRP) and erythrocyte sedimentation (ESR) were quantitatively analyzed by ROC curve. The final diagnosis was based on microbiological and histological examinations. The optimal cut-off value was chosen based on the ideal sensitivity and specificity. Results: Nine patients were diagnosed as septic loosening, 17 patients aseptic loosening, 1 patient bursitis of hip joint and 1 patient suture reaction. Taking the positive results of blood flow phase or blood pool phase as standard for diagnosing septic loosening, the sensitivity, specificity and accuracy of bone scintigraphy were 7/9, 78.9% (15/19) and 78.6% (22/28), respectively. The AUC of blood pool phase was 0.942, and the sensitivity and specificity were 8/9 and 78.9% (15/19), respectively, with the optimal cut-off value of 1.40. The AUCs of blood flow ratio and CRP were 0.816 and 0.795, with cut-off values of 1.53 and 1.20, respectively. The AUCs of static phase ratio and ESR were 0.474 and 0.722, respectively, both P>0.05. Conclusions: For the diagnosis of septic loosening, quantitative analysis of triphasic 99 Tc m -MDP bone scintigraphy, particularly with the ratio of blood pool phase, is more accurate than qualitative analysis. (authors)

  16. Analysis of {sup 18} F-FDG uptake patterns in PET for diagnosis of septic and aseptic loosening after total hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Cremerius, U.; Niethard, F.U. [Rheinisch-Westfaelische Technische Hochschule Aachen (Germany). Klinik fuer Nuklearmedizin; Mumme, T.; Reinartz, P.; Wirtz, D. [Rheinisch-Westfaelische Technische Hochschule Aachen (Germany). Orthopaedische Klinik; Buell, U.

    2003-12-01

    Aim: Identification of typical patterns for fluorodeoxyglucose (FDG) uptake in positron emission tomography (PET) to detect aseptic loosening of hip prosthesis (acetabular and/or femoral component) and prosthetic infection. Methods: 18 patients with painful hip prosthesis underwent PET using a dedicated full ring scanner after application of 200-300 MBq FDG. The interface between bone and surrounding soft tissue or bone as displayed on coronal slices was divided into 12 segments in accordance with the classifications of Delee and Gruen. FDG uptake in each of the segments was scored (0-3) by two independent observers. Intraoperative findings were regarded as the gold standard. Results: After surgical revision 14 acetabular components and 9 femoral components were found to be loose and prosthetic infection was present in 7 prostheses. Loosening of the acetabular component was correlated to enhanced uptake in the middle of the acetabular interface, while loosening of the femoral component was correlated to enhanced uptake in the proximal and middle segment of the lateral femoral interface and the proximal segment of the medial femoral interface. A similar pattern was found in prosthetic infection with high uptake along the middle portion of the lateral femoral interface. In 6 of 7 infected prostheses loosening of the acetabular and of the femoral component was present. Taking the typical uptake patterns as criteria for loosening and grade 3 uptake as an additional criterion for septic loosening the accuracy of PET imaging in the detection of loosening of the acetabular or the femoral component and of prosthetic infection was 72, 78 and 89%, respectively. Conclusion: This pilot study presents FDG-PET as a promising diagnostic tool for patients with painful hip prostheses. Its clinical value should be evaluated in a larger patient population. (orig.) [German] Ziel: Identifikation von Befundmustern in der Positronenemissionstomographie (PET) mit {sup 18}F

  17. Usefulness of positron emission tomography (TEP) in the assessment of osteo-articular prosthesis

    International Nuclear Information System (INIS)

    Maldonado, A.; Suarez, J.P.; Dominguez, M.L.

    2004-01-01

    Joint arthroplasty is performed with increasing frequency as the population ages. Loosening or infection of the prosthesis is a relatively common event that can limit the lifetime of a prosthesis. Accuracy differentiation between aseptic and septic loosening of the prosthesis remains a challenge because of the consequences for patient management. Moreover, an early diagnosis of infected hip prosthesis is very important for optimal and cost-effective management. Various approaches have developed to visualize infection and inflammation by nuclear medicine techniques. Recently positron emission tomography (PET) with fluorine-l8 labelled 2 fluoro-2-deoxyglucose ( 18 F-FDG) has been shown to delineate infectious and inflammatory foci with high sensitivity owing to the increased glucose metabolism in inflammatory cells. In this paper we review the role of FDG-PET in this common differential diagnosis in patients with total knee and hip prostheses. Different patterns of FDG-PET interpretation have been described as wed as methodological aspects. (author)

  18. Gene therapy and cement injection for the treatment of hip prosthesis loosening in elderly patients

    NARCIS (Netherlands)

    Poorter, Jolanda de

    2010-01-01

    Approximately one million total hip replacement operations are performed worldwide annually, mostly for osteoarthritis and rheumatoid arthritis. A major complication in total hip arthroplasties is loosening of the prosthesis leading to pain and walking difficulties and a higher risk for dislocations

  19. In vitro comparison of the biological activity of alumina ceramic and titanium particles associated with aseptic loosening

    International Nuclear Information System (INIS)

    Ding Yue; Qin Chuqiang; Xu Jie; Huang Dongsheng; Fu Yuru

    2012-01-01

    Prosthetic wear particles are thought to play a central role in the initiation and development of periprosthetic osteolysis, leading to aseptic loosening of prostheses. This study aimed to compare the biological activity of ceramic and titanium particles that are associated with particle-induced, aseptic joint loosening. Different sizes of alumina-ceramic particles and titanium particles were prepared to stimulate murine macrophage cells RAW 264.7, of which the expressions of tumor necrosis factor alpha (TNF-alpha) and receptor activator of nuclear factor-κB ligand (RANKL) were measured by qPCR and ELISA at various time points. In the presence of all particles, the expression of TNF-alpha increased in a time-dependent manner, whereas the expression of RANKL showed no regular expression patterns. Notably, particles of smaller sizes provoked significantly higher levels of TNF-alpha and RANKL than those of larger sizes. Compared to the titanium particles, the ceramic particles provoked a significantly lower production of TNF-alpha. Thus, the bioactivities of titanium and alumina ceramic particles were inversely proportional to the sizes of the particles, and the expression of RANKL was not parallel to that of TNF-alpha. The successful outcome of ceramic-on-ceramic artificial joint prostheses may be attributed to the low biological activity of ceramic particles, as evidenced here. (paper)

  20. A Medical Wireless Measurement System for Hip Prosthesis Loosening Detection Based on Vibration Analysis

    Directory of Open Access Journals (Sweden)

    Sebastian Sauer

    2013-01-01

    Full Text Available Vibration analysis is a promising approach in order to detect early hip prosthesis loosening, with the potential to extend the range of diagnostic tools currently available in clinical routine. Ongoing research efforts and developments in the area of multi-functional implants, which integrate sensors, wireless power supply, communication and signal processing, provide means to obtain valuable in vivo information otherwise not available. In the current work a medical wireless measurement system is presented, which is integrated in the femoral head of a hip prosthesis. The passive miniaturized system includes a 3-axis acceleration sensor and signal pre-processing based on a lock-in amplifier circuit. Bidirectional data communication and power supply is reached through inductive coupling with an operating frequency of 125 kHz in accordance with the ISO 18000-2 protocol standard. The system allows the acquisition of the acceleration frequency response of the femur-prosthesis system between 500 to 2500 Hz. Applied laboratory measurements with system prototypes on artificial bones and integrated prostheses demonstrate the feasibility of the measurement system approach, clearly showing differences in the vibration behavior due to an implant loosening. In addition a possibility to evaluate the non-linear mechanic system behavior is presented.

  1. SPECT scintigraphy with HDP and Mab BW 250/183 of loosened hip endoprothesis

    Energy Technology Data Exchange (ETDEWEB)

    Predic, P [Hospital Celje, Celje (Sierra Leone); Gregoric, E [Hospital Izola, Izola (Sierra Leone); Dodig, D [Clinical Hospital Centre, Zagreb (Croatia). Dept. of Nuclear Medicine and Radiation Protection

    1994-10-01

    Main problem of the loosened hip endoprothesis is in distinguishing between the aseptic and septic loosening of endoprothesis. The study involved 27 pts with a loosened hip; 15 pts with aseptic and 12 pts with septic loosening. The patients were injected 550-770 MBq Tc-99m-HDP and underwent SPECT scintigraphy of the hips to repeat then the examination with only 370 MBq Tc-99m-Mab Bw 230/183. HDP application evidenced positive accumulation at the endoprothesis in all patients with a loosened hip while Mab Bw 250/183 only in the patients with septic loosening. Conclusion: SPECT scintigraphy of hip endoprothesis with HDP and Mab BW 250/183 allows differential diagnosing between septic and aseptic hip loosening and hereby a correct therapeutical approach. (author).

  2. The inhibitory effect of strontium-doped calcium polyphosphate particles on cytokines from macrophages and osteoblasts leading to aseptic loosening in vitro

    International Nuclear Information System (INIS)

    Huang, Chengcheng; Yu, Xixun; Gu, Zhipeng; Li, Li; Zhang, Xu

    2014-01-01

    Aseptic loosening is a common cause of joint implant failure in humans. In order to enhance implant stability, we need to develop a new material that not only promotes the wear resistance of components of an artificial joint, but also possesses the pharmaceutical efficacy of protecting patients against aseptic loosening. Strontium-doped calcium polyphosphate (SCPP) has been found to have this potential ability. The goal of this study is to respectively quantify the levels of TNF-α (for macrophages), receptor activator of NF- k B ligand (RANKL) and osteoprotegerin (OPG) (for osteoblasts) when osteoblasts and macrophages are challenged with various particles (including SCPP). In this study, the osteoblasts ROS 17/2.8 and macrophages RAW 264.7 were challenged with various wear particles (8% SCPP, the molar percentage of Sr in SCPP is 8%, UHMWPE, hydroxyapatite (HA) and CPP). The secretion of TNF-α (from RAW 264.7), OPG and RANKL protein (from ROS 17/2.8) was analyzed by ELISA. The OPG and RANKL mRNA from ROS 17/2.8 was detected by RT-PCR. The data of ELISA indicated that the amount of TNF-α challenged with 8% SCPP particles was more than three-fold lower than that of all other test groups. The ratio of OPG/RANKL in the 8% SCPP group was significantly increased compared to that of all other test groups. The results of OPG and RANKL mRNA expression showed the same tendency as the ELISA results. In general, this study showed that 8% SCPP particles can inhibit the expression of TNF-α and RANKL, promote the expression of OPG so that SCPP can inhibit bone resorption and promote bone formation, and then inhibit aseptic loosening. Thus SCPP could be a promising material for the construction of artificial joints. (paper)

  3. Wear Particles Promote Reactive Oxygen Species-Mediated Inflammation via the Nicotinamide Adenine Dinucleotide Phosphate Oxidase Pathway in Macrophages Surrounding Loosened Implants

    Directory of Open Access Journals (Sweden)

    Weishen Chen

    2015-03-01

    Full Text Available Background/Aims: Prosthesis loosening is closely associated with chronic inflammatory cytokine secretion by macrophages, which are activated by wear particles or inflammatory stimulants such as lipopolysaccharide (LPS. Reactive oxygen species (ROS are critical regulators of inflammation, but their enzymatic sources in response to wear particles and their effects on peri-implant LPS-tolerance remain unclear. Methods: Three ROS-related enzymes—nicotinamide adenine dinucleotide phosphate oxidase (NOX-1 and -2 and catalase—were investigated in interface membrane tissues and in titanium (Ti particle-stimulated macrophages in vitro. The generation of ROS and downstream inflammatory effects were measured with or without pre-incubation with apocynin, an NOX inhibitor. Results: Pre-exposure to Ti particles attenuated NF-κB activation in LPS-stimulated macrophages, indicating that wear particles suppress immune response, which may lead to chronic inflammation. NOX-1 and -2 were highly expressed in aseptically loosened interface membranes and in macrophages stimulated with Ti particles; the particles induced a moderate amount of ROS generation, NF-κB activation, and TNF-a secretion in macrophages, and these effects were suppressed by apocynin. Conclusion: Wear particles induce ROS generation through the NOX signaling pathway, resulting in persistent inflammation and delayed loosening. Thus, the suppression of NOX activity may be a useful strategy for preventing prosthesis loosening.

  4. A Stereophotogrammetric System For The Detection Of Prosthesis Loosening In Total Hip Arthroplasty

    Science.gov (United States)

    Baumrind, Sheldon; Genant, Harry K.; Hunter, John; Miller, David; Moffitt, Francis; Murray, William R.; Ross, Steven E.

    1980-07-01

    Loosening of the prosthetic device occurs in about 5% of cases following placement of total hip prostheses (THP). Early detection of loosening is much desired but is difficult to achieve using conventional methods. Due to errors of projection, it is quite possible to fail to detect mobility of even as much as 5 mm on single x-ray films. We are attempting to develop a simplified photogrammetric system suitable for general hospital use which could detect loosening of 0.8 mm at the 95 % level of confidence without use of complex stereoplotting equipment. Metal reference markers are placed in the shaft of the femur and in the acetabular region of the pelvis at the time of surgery. The distances between these reference markers and certain unambiguous points on the prostheses are computed analytically using an X-Y acoustical digitizer (accuracy ± 0.1 mm) and software developed previously for craniofacial measurement. Separate stereopairs of the joint region are taken under weight-bearing and nonweight-bearing conditions. Differences in the measured distances between the bo-ne markers and the prosthetic components on the two stereopairs are taken as indicators of prosthesis loosening. Measurements on a phantom using ten different x-ray stereopairs taken from as many different perspectives have established that true linear distances between reference points and prostheses can be measured at the desired reliability with the present low precision system. Preliminary in vivo measurements indicate that the main unresolved problem is the movement of the subject between the two exposures of each single stereopair. Two possible solutions to this problem are discussed.

  5. Metal is not inert: role of metal ions released by biocorrosion in aseptic loosening--current concepts.

    Science.gov (United States)

    Cadosch, Dieter; Chan, Erwin; Gautschi, Oliver P; Filgueira, Luis

    2009-12-15

    Metal implants are essential therapeutic tools for the treatment of bone fractures and joint replacements. The metals and metal alloys used in contemporary orthopedic and trauma surgery are well tolerated by the majority of patients. However, complications resulting from inflammatory and immune reactions to metal implants have been well documented. This review briefly discusses the different mechanisms of metal implant corrosion in the human body, which lead to the release of significant levels of metal ions into the peri-implant tissues and the systemic blood circulation. Additionally, this article reviews the effects of the released ions on bone metabolism and the immune system and discusses their involvement in the pathophysiological mechanisms of aseptic loosening and metal hypersensitivity in patients with metal implants.

  6. Usefulness of positron emission tomography (TEP) in the assessment of osteo-articular prosthesis; Utilite de la tomographie par emission de positons (TEP) dans l'etude des protheses osteo-articulaires

    Energy Technology Data Exchange (ETDEWEB)

    Maldonado, A.; Suarez, J.P.; Dominguez, M.L. [Centro PET Complutense, Madrid (Spain)

    2004-12-15

    Joint arthroplasty is performed with increasing frequency as the population ages. Loosening or infection of the prosthesis is a relatively common event that can limit the lifetime of a prosthesis. Accuracy differentiation between aseptic and septic loosening of the prosthesis remains a challenge because of the consequences for patient management. Moreover, an early diagnosis of infected hip prosthesis is very important for optimal and cost-effective management. Various approaches have developed to visualize infection and inflammation by nuclear medicine techniques. Recently positron emission tomography (PET) with fluorine-l8 labelled 2 fluoro-2-deoxyglucose ({sup 18}F-FDG) has been shown to delineate infectious and inflammatory foci with high sensitivity owing to the increased glucose metabolism in inflammatory cells. In this paper we review the role of FDG-PET in this common differential diagnosis in patients with total knee and hip prostheses. Different patterns of FDG-PET interpretation have been described as wed as methodological aspects. (author)

  7. Surgical treatment of isolated aseptic acetabular loosening of the hip joint

    Directory of Open Access Journals (Sweden)

    Zvereva К.Р.

    2017-09-01

    Full Text Available Aseptic acetabular loosening is one of the most common complications of primary hip arthroplasty Its treatment is possible in the volume of replacement of only the endoprosthesis cup with the preservation of a stable correctly oriented femoral component. The sequence of actions consists of provision of access to the acetabulum component and its replacement, after which the necessary offset is selected by changing the size of the head and installing a new pair of friction. Currently, the vast majority of the installed heads during the primary and revision hip replacement have a standard size forthe cone of the femoral component 12/14mm. According to the observations, in 3% of cases, there are femoral components with non-standard cone sizes 11/13 mm, usually established 7-8 years ago. The absence of heads forthe necessary cone leads to the need to replace the stable correctly oriented femoral component, which is accompanied by an increase in the time of intervention, the volume of intraoperative blood loss and the risk of intraopera-tive peri-prosthetic fracture. We represent the clinical case of a 75-year-old patient with a dislocation of the acetabular component and a stable correctly oriented femoral component, which during the audit intervention due to the lack of heads for an irregular cone size, total replacement of the components was made.

  8. Interleukin-6 in serum and in synovial fluid enhances the differentiation between periprosthetic joint infection and aseptic loosening.

    Directory of Open Access Journals (Sweden)

    Thomas M Randau

    Full Text Available The preoperative differentiation between septic and aseptic loosening after total hip or knee arthroplasty is essential for successful therapy and relies in part on biomarkers. The objective of this study was to assess synovial and serum levels of inflammatory proteins as diagnostic tool for periprosthetic joint infection and compare their accuracy with standard tests. 120 patients presenting with a painful knee or hip endoprosthesis for surgical revision were included in this prospective trial. Blood samples and samples of intraoperatively acquired joint fluid aspirate were collected. White blood cell count, C-reactive protein, procalcitonin and interleukin-6 were determined. The joint aspirate was analyzed for total leukocyte count and IL-6. The definite diagnosis of PJI was determined on the basis of purulent synovial fluid, histopathology and microbiology. IL-6 in serum showed significantly higher values in the PJI group as compared to aseptic loosening and control, with specificity at 58.3% and a sensitivity of 79.5% at a cut-off value of 2.6 pg/ml. With a cut-off >6.6 pg/ml, the specificity increased to 88.3%. IL-6 in joint aspirate had, at a cut-off of >2100 pg/ml, a specificity of 85.7% and sensitivity of 59.4%. At levels >9000 pg/ml, specificity was almost at 100% with sensitivity just below 50%, so PJI could be considered proven with IL-6 levels above this threshold. Our data supports the published results on IL-6 as a biomarker in PJI. In our large prospective cohort of revision arthroplasty patients, the use of IL-6 in synovial fluid appears to be a more accurate marker than either the white blood cell count or the C-reactive protein level in serum for the detection of periprosthetic joint infection. On the basis of the results we recommend the use of the synovial fluid biomarker IL-6 for the diagnosis of periprosthetic joint infection following total hip and knee arthroplasty.

  9. Interleukin-6 in serum and in synovial fluid enhances the differentiation between periprosthetic joint infection and aseptic loosening.

    Science.gov (United States)

    Randau, Thomas M; Friedrich, Max J; Wimmer, Matthias D; Reichert, Ben; Kuberra, Dominik; Stoffel-Wagner, Birgit; Limmer, Andreas; Wirtz, Dieter C; Gravius, Sascha

    2014-01-01

    The preoperative differentiation between septic and aseptic loosening after total hip or knee arthroplasty is essential for successful therapy and relies in part on biomarkers. The objective of this study was to assess synovial and serum levels of inflammatory proteins as diagnostic tool for periprosthetic joint infection and compare their accuracy with standard tests. 120 patients presenting with a painful knee or hip endoprosthesis for surgical revision were included in this prospective trial. Blood samples and samples of intraoperatively acquired joint fluid aspirate were collected. White blood cell count, C-reactive protein, procalcitonin and interleukin-6 were determined. The joint aspirate was analyzed for total leukocyte count and IL-6. The definite diagnosis of PJI was determined on the basis of purulent synovial fluid, histopathology and microbiology. IL-6 in serum showed significantly higher values in the PJI group as compared to aseptic loosening and control, with specificity at 58.3% and a sensitivity of 79.5% at a cut-off value of 2.6 pg/ml. With a cut-off >6.6 pg/ml, the specificity increased to 88.3%. IL-6 in joint aspirate had, at a cut-off of >2100 pg/ml, a specificity of 85.7% and sensitivity of 59.4%. At levels >9000 pg/ml, specificity was almost at 100% with sensitivity just below 50%, so PJI could be considered proven with IL-6 levels above this threshold. Our data supports the published results on IL-6 as a biomarker in PJI. In our large prospective cohort of revision arthroplasty patients, the use of IL-6 in synovial fluid appears to be a more accurate marker than either the white blood cell count or the C-reactive protein level in serum for the detection of periprosthetic joint infection. On the basis of the results we recommend the use of the synovial fluid biomarker IL-6 for the diagnosis of periprosthetic joint infection following total hip and knee arthroplasty.

  10. Radionuclide imaging of the painful joint replacement: past, present and future

    Energy Technology Data Exchange (ETDEWEB)

    Palestro, Christopher J. [Long Island Jewish Medical Center, New Hyde Park, NY (United States)]. E-mail: palestro@lij.edu

    2002-09-01

    Differentiating aseptic loosening from infection as the cause of prosthetic joint failure is difficult because both entities are similar, clinically and histopathologically. Aseptic loosening frequently result from an immune reaction to the prosthesis. There is inflammation with an influx of histiocytes, giant cells, lymphocytes and plasma cells. Pro inflammatory cytokines and proteolytic enzymes are secreted, causing osteolysis and loosening. These same events occur in infection except that neutrophils, rarely present in aseptic loosening, area invariably present in infection. Clinical signs and symptoms, laboratory tests, X-rays and joint aspiration are insensitive, nonspecific or both. Artifacts produced by the metallic hardware hamper cross-sectional imaging modalities. Radionuclide imaging is not affected by the presence of metallic hardware and is very useful for evaluating the painful prosthesis. Bone scintigraphy, with and accuracy of 50%-70% is a useful screening test, since a normal study effectively excludes a prosthetic complication. Adding gallium-67, a nonspecific inflammation-imaging agent, improves the accuracy of bone scintigraphy to 70%-80%. The accuracy of combined leukocyte/marrow imaging, 90%, is the highest among available radionuclide studies. Its success is due to the fact that leukocytes imaging is most sensitive for detecting neutrophil mediated inflammations. Inflammatory conditions that are neutrophil-poor, even though large numbers of other leukocytes may be present, (such as the aseptically loosened joint prosthesis) go undetected. The success of leukocyte/marrow imaging is tempered by the limitations of in vitro labeling. In vivo labeling has been investigated and a murine monoclonal anti-granulocyte antibody appears promising. Some investigations have focused on F-18 FDG imaging, although specificity is a concern with this agent. (author)

  11. Radionuclide imaging of the painful joint replacement: past, present and future

    International Nuclear Information System (INIS)

    Palestro, Christopher J.

    2002-01-01

    Differentiating aseptic loosening from infection as the cause of prosthetic joint failure is difficult because both entities are similar, clinically and histopathologically. Aseptic loosening frequently result from an immune reaction to the prosthesis. There is inflammation with an influx of histiocytes, giant cells, lymphocytes and plasma cells. Pro inflammatory cytokines and proteolytic enzymes are secreted, causing osteolysis and loosening. These same events occur in infection except that neutrophils, rarely present in aseptic loosening, area invariably present in infection. Clinical signs and symptoms, laboratory tests, X-rays and joint aspiration are insensitive, nonspecific or both. Artifacts produced by the metallic hardware hamper cross-sectional imaging modalities. Radionuclide imaging is not affected by the presence of metallic hardware and is very useful for evaluating the painful prosthesis. Bone scintigraphy, with and accuracy of 50%-70% is a useful screening test, since a normal study effectively excludes a prosthetic complication. Adding gallium-67, a nonspecific inflammation-imaging agent, improves the accuracy of bone scintigraphy to 70%-80%. The accuracy of combined leukocyte/marrow imaging, 90%, is the highest among available radionuclide studies. Its success is due to the fact that leukocytes imaging is most sensitive for detecting neutrophil mediated inflammations. Inflammatory conditions that are neutrophil-poor, even though large numbers of other leukocytes may be present, (such as the aseptically loosened joint prosthesis) go undetected. The success of leukocyte/marrow imaging is tempered by the limitations of in vitro labeling. In vivo labeling has been investigated and a murine monoclonal anti-granulocyte antibody appears promising. Some investigations have focused on F-18 FDG imaging, although specificity is a concern with this agent. (author)

  12. 99m technetium-MDP bone scintigraphy in evaluation of painful joint prosthesis

    International Nuclear Information System (INIS)

    Milosevic, D.; Jaukovic, M.; Jaukovic, Lj.; Ajdinovic, B.

    2004-01-01

    In addition of clinical evaluation and x-ray radiography, the diagnosis of a loose joint prosthesis is often made by nuclear medicine imaging techniques. Differentiation between loosening and infected prosthesis is important for better treatment of those patients. Aim: The aim of this study was to reevaluate the scintigraphic patterns in patients with painful hip of knee arthroplasty. Material and Method: From 1996. to 2003. forty patients aged 49-78 years were referred for evaluation of possible loosening/infection joint prosthesis: 36 pts with 39 total/ partial hip prosthesis, 1 pt with knee prosthesis and 3 pts with history of previously extracted hip prosthesis due to infection. Whole body acquisition had been performed with a single head gamma camera three hours after the injection of 740 MBq 99m Tc-MDP. Scans were classified as: positive for loosening if abnormal uptake was shown at the tip of the prosthesis; positive for infection if diffuse abnormal uptake was shown around the implant; negative and indeterminate scans. Scintigraphic findings were compared to clinical follow up, histology or cultures. Results: Positive findings were found in 17 bone scans strongly suggesting loosening in 10 cases, infection of prosthesis in 4 cases and both loosening/infection in 3 cases. Bone scintigraphy was normal in 11pts. Scans of three pts with previously extracted hip prosthesis and scheduled for reimplatation, showed inhomogeneously and mildly increased uptake in femur. Most of scans classified as indeterminate (n=12) showed slightly increased tracer uptake in region of acetabular roof, greater or lesser tho chanter, suggesting bone remodeling due to the presence of implant, rather than loosening. Conclusion: 99m Tc-MDP bone scintigraphy had a significant role in assessing the painful joint prosthesis. Complementary diagnostic procedures should be considered in indeterminate scintiscans. (authors)

  13. Comparative study of radiography and scintigraphy for loosening and infection of prosthetic hip replacement

    International Nuclear Information System (INIS)

    Park, Mi Sook; Lee, Sun Wha; Choi, Woo Suk; Lim, Joo Won; Song, Han Joon; Ahn, Chi Yul

    1987-01-01

    Prosthetic hip replacement is associated with certain complications which result in a painful hip. Many of these, e. g. prosthetic dislocation, fracture, trochanteric avulsion, and heterotopic calcification are easily diagnosed by conventional radiography. However, radiographic evaluation for infection and/pr loosening of prosthesis as major complications requiring reoperation often contributes little to the resolution of the diagnostic problem. The authors made a comparative study of plain radiography and scintigraphy of 39 cases performed revision at Kyung Hee University Hospital from Sep. '81-to Aug. '86. The results were as follows: 1. In 39 revised prosthetic hip replacement, 26 cases (67%) of loosening without infection and 11 cases (28%) of infection were proven. 2. In loosening of prosthesis, plain radiography showed true positive rate of 76% and true negative rate of 60%, and scintigraphy showed true positive rate of 75% and true negative rate of 95%. 3. In infection of prosthesis, plain radiography revealed true positive rate of 55% and true negative rate of 96%, and scintigraphy revealed true positive rate of 100% and true negative rate of 83%. 4. Scintigraphy and plain radiography were useful as complementary procedure in evaluating and differentiating loosening and/or infection of prosthetic component

  14. Comparative study of radiography and scintigraphy for loosening and infection of prosthetic hip replacement

    Energy Technology Data Exchange (ETDEWEB)

    Park, Mi Sook; Lee, Sun Wha; Choi, Woo Suk; Lim, Joo Won; Song, Han Joon; Ahn, Chi Yul [College of Medicine, Kyung Hee University, Seoul (Korea, Republic of)

    1987-10-15

    Prosthetic hip replacement is associated with certain complications which result in a painful hip. Many of these, e. g. prosthetic dislocation, fracture, trochanteric avulsion, and heterotopic calcification are easily diagnosed by conventional radiography. However, radiographic evaluation for infection and/pr loosening of prosthesis as major complications requiring reoperation often contributes little to the resolution of the diagnostic problem. The authors made a comparative study of plain radiography and scintigraphy of 39 cases performed revision at Kyung Hee University Hospital from Sep. '81-to Aug. '86. The results were as follows: 1. In 39 revised prosthetic hip replacement, 26 cases (67%) of loosening without infection and 11 cases (28%) of infection were proven. 2. In loosening of prosthesis, plain radiography showed true positive rate of 76% and true negative rate of 60%, and scintigraphy showed true positive rate of 75% and true negative rate of 95%. 3. In infection of prosthesis, plain radiography revealed true positive rate of 55% and true negative rate of 96%, and scintigraphy revealed true positive rate of 100% and true negative rate of 83%. 4. Scintigraphy and plain radiography were useful as complementary procedure in evaluating and differentiating loosening and/or infection of prosthetic component.

  15. Numerical analysis of the biomechanical complications accompanying the total hip replacement with NANOS-Prosthetic: bone remodelling and prosthesis migration

    Directory of Open Access Journals (Sweden)

    Almohallami A.

    2015-09-01

    Full Text Available Aseptic loosening of the prosthesis is still a problem in artificial joint implants. The ýloosening can be caused by the resorption of the bone surrounding ýthe prosthesis according to stress shielding. A numerical model was developed and validated by means of DEXA-studies in order to ýanalyse the bone remodelling process in the periprosthetic bone. A total loss of about 3.7% of the bone density in the periprosthetic Femur with NANOS is computed. The bone remodelling calculation was validated by means of a DEXA-study with a 3-years-follow-up. The model was further developed in order to be able to calculate and consider the migration of the implants. This method was applied on the ýNANOS-implant with a computed total migration of about 0.43 mm. These calculations showed good results in comparison with a 2-year-follow-up clinical study, whereby a RSA-method was used to determine the stem migration in the bone. In order to ýstudy the mutual influence between the implant migration and the hip contact forces ý, a software is developed by our scientific group to couple a multi body simulation (MBS of human lower limps with the FEA of the periprosthetic Femur.

  16. Long-term outcome of acute prosthetic joint infections due to gram-negative bacilli treated with retention of prosthesis.

    Science.gov (United States)

    Jaén, N; Martínez-Pastor, J C; Muñoz-Mahamud, E; García-Ramiro, S; Bosch, J; Mensa, J; Soriano, A

    2012-09-01

    To update the clinical information of the 47 patients with a prosthetic joint infection due to Gram-negative bacilli included in a previous study and to reassess the predictors of failure after a longer follow-up. Using the electronic files of our hospital, all the information regarding readmissions to the hospital, new surgical procedures and the reason for the new surgery (infection, aseptic loosening), and the last visit in the hospital were registered. The medical chart of the 35 patients that were considered in remission in the previous publication was reviewed. In 30 patients no clinical evidence of failure was detected and no additional surgery on the previously infected prosthesis was necessary and they were considered in long-term remission. In 5 cases a late complication was identified. One case had a reinfection due to coagulase-negative staphylococci after 22 months from the open debridement and required a 2-stage revision surgery. The other 4 cases developed an aseptic loosening and it was necessary to perform a 1-stage exchange. Receiving a fluoroquinolone when all the Gram-negatives involved in the infection were susceptible to fluoroquinolones was the only factor associated with remission in the univariate analysis (p=0.002). After a long-term follow-up, our results support the importance of using fluoroquinolones in acute PJI due to Gram-negative bacilli.

  17. Femoral component loosening after hip resurfacing arthroplasty

    International Nuclear Information System (INIS)

    Zustin, Jozef; Sauter, Guido; Hahn, Michael; Morlock, Michael M.; Ruether, Wolfgang; Amling, Michael

    2010-01-01

    Before the re-introduction of the current generation of total hip resurfacing arthroplasty, component loosening and osteolysis were of great concern to the orthopaedic community. Early, mid- and long-term clinical results are encouraging, but component loosening still exists. Macroscopic, contact radiographic and histopathological analyses after undecalcified preparation of bone tissue specimens were performed. To investigate the frequency and morphological patterns of the loosening of the femoral component, we analysed a series of 190 retrieved femoral remnants that were revised for aseptic failures. Thirty-five (18.4%) hips were revised for clinical and/or radiographic loosening of the femoral component. Pseudoarthrosis (n = 17; median in situ time: 16 weeks, interquartile range [IQR]: 9 to 34), collapsed osteonecrosis (n = 5; median in situ time: 79 weeks, IQR: 63 to 97), cement-socket debonding (n = 3; median in situ time: 89 weeks, IQR: 54 to 97) and at later follow-up bone-cement loosening (n = 10; median in situ time: 175 weeks; IQR 112 to 198; p =0.005) were distinct patterns of the femoral remnant-implant loosening. Fibrocartilaginous metaplasia of interface bone trabeculae (n = 38; median in situ time: 61 weeks, IQR: 32 to 138) was strongly associated with femoral component loosening (p = 0.009). Both the trabecular hyperosteoidosis (n = 32; median in situ time: 71 weeks, IQR 50 to 129) and excessive intraosseous lymphocyte infiltration (n = 12; median in situ time: 75 weeks, IQR 51 to 98) at the bone-cement interface correlated strongly with fibrocartilaginous metaplasia (p = 0.001 and p = 0.016 respectively) and all three lesions were associated with the female gender (p = 0.021, p = 0.009, and p = 0.051). Femoral component loosening at early follow-up was mostly caused by pathological changes of the femoral remnant bone tissue: pseudoarthrosis and collapsed osteonecrosis. Fibrocartilaginous metaplasia was frequently observed in hips with femoral

  18. Comparison of radiographic and radionuclide hip arthrography in determination of femoral component loosening of hip arthroplasties

    International Nuclear Information System (INIS)

    Capello, W.N.; Uri, B.G.; Wellman, H.N.; Robb, J.A.; Stiver, P.L.

    1985-01-01

    Radiographic examination of a patient experiencing pain following total hip arthroplasty is an important step in the systematic approach to evaluating component loosening, even though the information yielded is often equivocal and nondiagnostic in assessing component loosening. The radiographic criteria for loosening are especially difficult to assess following revision surgery, for radiolucent lines frequently exist at the bone-cement interface immediately following implantation. The advent of noncemented hip prostheses poses another problem: the routinely noted disruption of bone-cement of prosthesis-cement interfaces is not present with uncemented prostheses. As the criteria for loosening of the noncemented prostheses are still evolving, plain radiographic examination is frequently nondiagnostic. Femoral component loosening is difficult to detect with standard contrast arthrography because the bone, metal, surrounding radiopaque cement and contrast agents have similar or identical radiographic appearances. In contrast arthrography, if the prosthesis is loose the injected agent opacifies the radiolucent zone encircling the prosthesis or cement mangle. Because of the similarity in the appearances of these agents and the surrounding structures on x-ray films, interpretation is difficult. The inclusion of subtraction techniques in routine contrast arthrography has improved its accuracy; however, these techniques require special equipment and demand precise patient positioning. The purpose of this study is to introduce a new form of hip arthrography using a radionuclide agent in place of the contrast agent. A comparison of the results using these two techniques is presented

  19. Dual X-ray absortiometry(DXA) in the detection of loosening in the total hip replacement arthroplasty: preliminary study

    International Nuclear Information System (INIS)

    Yoon, Hye Kyung; Kang, Heung Sik; Han, Man Chung; Kim, Hee Joong; Kim, Young Min

    1994-01-01

    Algorithms to get cross-sectional bone density pattern(transverse histogram) to predict the loosening of hip prosthesis using DXA(Dual X-ray Absorptiometry) have been developed. We performed this study to analyze the correlation between radiologic findings and densitometric pattern of the THRA(Total Hip Replacement Arthroplasty) patients. Thirty-six hips of 32 THRA patients were evaluated. The duration between THRA and DXA was from 1 year 7 months to 15 years. On transverse histogram, the periprosthetic bone density patterns were classified as 3 types; type I , rigid fixation in 17, type II definite loosening in 8, and type III, partial loosening in 11 cases. Surgical findings, plain X-ray findings and transverse histogram using DXA were correlated. Among 14 cases performing revision for acetabular prosthesis loosening, 5 cases revealed loosening of femoral stems while 9 cases revealed rigid fixation of femoral stems. Sensitivity was 100% for either plain X-ray or DXA. Specificity was 88%, 77% for plain X-ray and DXA respectively. This preliminary study reveals that periprosthetic bone density pattern on transverse histogram on DXA may be useful in the evaluation of the loosening. However, further study will be needed for clinical application

  20. Failed total carpometacarpal joint prosthesis of the thumb

    DEFF Research Database (Denmark)

    Hansen, Torben Bæk; Homilius, Morten

    2010-01-01

    Total joint prosthesis in carpometacarpal joint arthritis of the thumb often fails. Loosening of the implant is often treated by resection arthroplasty, and we reviewed 10 patients, mean age 54 years (range 47-63) who were treated by resection arthroplasty after a failed total joint prosthesis. T...... in eight of 10 patients, but the mean Disabilities of the arm, shoulder, and hand (DASH) scores, self-reported pinch-grip-related function, and pain were comparable with our earlier published results with the Elektra carpometacarpal total joint prosthesis.......Total joint prosthesis in carpometacarpal joint arthritis of the thumb often fails. Loosening of the implant is often treated by resection arthroplasty, and we reviewed 10 patients, mean age 54 years (range 47-63) who were treated by resection arthroplasty after a failed total joint prosthesis....... The male:female ratio was 1:4 and the mean duration of observation 32 months (range 6-52). In three patients the revised implant was a MOJE uncemented carpometacarpal joint prosthesis and in seven patients an Elektra uncemented one. At follow-up grip strength was reduced to less than 90% of the other hand...

  1. Molecular Identification of Bacteria from Aseptically Loose Implants

    Science.gov (United States)

    Kobayashi, Naomi; Procop, Gary W.; Krebs, Viktor; Kobayashi, Hideo

    2008-01-01

    Polymerase chain reaction (PCR) assays have been used to detect bacteria adherent to failed orthopaedic implants, but some PCR assays have had problems with probable false-positive results. We used a combination of a Staphylococcus species-specific PCR and a universal PCR followed by DNA sequencing to identify bacteria on implants retrieved from 52 patients (92 implants) at revision arthroplasty. We addressed two questions in this study: (1) Is this method able to show the existence of bacterial DNA on presumed aseptic loosed implants?; and (2) What proportion of presumed aseptic or culture-negative implants was positive for bacterial DNA by PCR? Fourteen implants (15%) were believed infected, whereas 74 implants (85%) were believed aseptic. Each implant was sonicated and the resulting solution was submitted for dual real-time PCR assay and culture. All implants believed aseptically loose were culture-negative, but nine of the 74 (12%) had bacterial DNA by PCR; two (2.7%) were PCR-positive and also showed histologic findings suggestive of infection. Uniquely developed PCR and bacterial sequencing assays showed bacterial DNA on 12% of implants removed for presumed aseptic loosening. Additional studies are needed to determine the clinical importance of bacterial DNA detected by PCR but not by conventional culture. Level of Evidence: Level III, diagnostic study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:18438724

  2. Split-Framework in Mandibular Implant-Supported Prosthesis

    Directory of Open Access Journals (Sweden)

    Danny Omar Mendoza Marin

    2015-01-01

    Full Text Available During oral rehabilitation of an edentulous patient with an implant-supported prosthesis, mandibular flexure must be considered an important biomechanical factor when planning the metal framework design, especially if implants are installed posterior to the interforaminal region. When an edentulous mandible is restored with a fixed implant-supported prosthesis connected by a fixed full-arch framework, mandibular flexure may cause needless stress in the overall restorative system and lead to screw loosening, poor fit of prosthesis, loss of the posterior implant, and patient’s discomfort due to deformation properties of the mandible during functional movements. The use of a split-framework could decrease the stress with a precise and passive fit on the implants and restore a more natural functional condition of the mandible, helping in the longevity of the prosthesis. Therefore, the present clinical report describes the oral rehabilitation of an edentulous patient by a mandibular fixed implant-supported prosthesis with a split-framework to compensate for mandibular flexure. Clinical Significance. The present clinical report shows that the use of a split-framework reduced the risk of loss of the posterior implants or screws loosening with acceptable patient comfort over the period of a year. The split-framework might have compensated for the mandibular flexure during functional activities.

  3. Femoral hip prosthesis design for Thais using multi-objective shape optimization

    International Nuclear Information System (INIS)

    Virulsri, Chanyaphan; Tangpornprasert, Pairat; Romtrairat, Parineak

    2015-01-01

    Highlights: • A multi-objective shape optimization was proposed to design hip prosthesis for Thais. • The prosthesis design was optimized in terms of safety of both cement and prosthesis. • The objective functions used the Soderberg fatigue strength formulations. • Safety factors of the cement and prosthesis are 1.200 and 1.109 respectively. • The newly designed prosthesis also fits well with chosen small-sized Thai femurs. - Abstract: The long-term success of Total Hip Arthroplasty (THA) depends largely on how well the prosthetic components fit the bones. The majority of cemented femoral hip prosthesis failures are due to aseptic loosening, which is possibly caused by cracking of the cement mantle. The strength of cement components is a function of cement mantles having adequate thickness. Since the size and shape of cemented femoral hip prostheses used in Thailand are based on designs for a Caucasian population, they do not properly conform to most Thai patients’ physical requirements. For these reasons, prostheses designed specifically for Thai patients must consider the longevity and functionality of both cement and prosthesis. The objective of this study was to discover a new design for femoral hip prostheses which is not only optimal and safe in terms of both cement and prosthesis, but also fits the selected Thai femur. This study used a small-sized Thai femoral model as a reference model for a new design. Biocompatible stainless steel 316L (SS316L) and polymethylmethacrylate (PMMA) were selected as raw materials for the prosthesis and bone cement respectively. A multi-objective shape optimization program, which is an interface between optimization C program named NSGA-II and a finite element program named ANSYS, was used to optimize longevity of femoral hip prostheses by varying shape parameters at assigned cross-sections of the selected geometry. Maximum walking loads of sixty-kilograms were applied to a finite element model for stress and

  4. Prosthetic Hip Loosening Due to Brucellar Infection: Case Report and Literature Review

    Directory of Open Access Journals (Sweden)

    Anis Tebourbi

    2016-12-01

    Full Text Available Context: Brucellosis is actually considered to be the commonest zoonotic infection worldwide; conversely prosthetic infection due to brucella is extremely rare. Although diagnostic is easily achieved, management of such situations is extremely challenging. Aims: To report the case of prosthetic hip loosening due to brucellar infection, discuss management manners and to summarize data about 19 cases reported in the literature. Methods: We report the case of a 73-year-old woman with brucellar prosthetic hip loosening treated with 2-stage exchange of the prosthesis and prolonged double antibiotherapy Results: At two years follow up the patient is pain free with total functional recovery and no clinical and radiographic signs of prosthetic loosening Conclusions: Brucella should be evocated as a cause of total joint arthroplasty infection especially in patients from endemic regions and with occupational exposure. Antibiotic treatment alone can be followed if there are no signs of implant loosening. Tow stage revision should be considered in other cases.

  5. Method and ranking of DSA of the hip in detecting loosening of endoprostheses

    International Nuclear Information System (INIS)

    Fink, B.K.; Fink, U.; Hansen, M.; Kirsch, C.M.; Pfahler, M.

    1991-01-01

    Digital subtraction arthrography (DSAr) of the operated hip is presented and compared to nuclide bone scan and plain radiograph. Surgical proof was obtained in 47 patients. In the evaluation DSAr proved to be superior to nuclide bone scan and plain radiograph. DSAr had the best predictive value in the diagnosis of loosening of a prosthesis. In contrast to conventional arthrography there is a better differentiation between the contrast medium, the prosthesis, the acryle cement and the bone by using DSAr. In addition DSAr presents the advantage of postprocessing, especially pixelshift. (orig.) [de

  6. Unusual way of loosened total hip arthroplasty treatment with an Austin Moore endoprosthesis

    OpenAIRE

    M Erceg; K Becic

    2014-01-01

    A 65-year-old female patient with aseptic loosening of total cemented hip endoprosthesis and pathologic fracture of the femur at the level of the stem of endoprosthesis was presented. As no appropriate endoprosthesis was available due to the war in Croatia and war priority, the problem was managed by femur osteosynthesis and implantation of a partial Austin Moore hip endoprosthesis. The endoprosthesis is still functioning well (for 20 years).To the best of the author′s knowledge, nobody has e...

  7. Humeral windows in revision total elbow arthroplasty.

    Science.gov (United States)

    Peach, Chris A; Salama, Amir; Stanley, David

    2016-04-01

    The use of cortical windows for revision elbow arthroplasty has not previously been widely reported. Their use aids safe revision of a well fixed humeral prosthesis and can be used in the setting of dislocation, periprosthetic fracture or aseptic loosening of the ulnar component. We describe our technique and results of cortical windows in the distal humerus for revision elbow arthroplasty surgery.

  8. Frequent complications and severe bone loss associated with the repiphysis expandable distal femoral prosthesis.

    Science.gov (United States)

    Cipriano, Cara A; Gruzinova, Irina S; Frank, Rachel M; Gitelis, Steven; Virkus, Walter W

    2015-03-01

    The treatment of choice for distal femur malignancies in skeletally immature patients remains controversial. An expandable endoprosthesis device (Repiphysis Limb Salvage System; Wright Medical Technology, Arlington, TN, USA) allows for limb preservation and noninvasive lengthening but has been associated with significant complications; however, the extent and implications of bone loss associated with this implant have not been reported. Our goals were to report (1) the 2-year minimum clinical outcomes after placement of the Repiphysis expandable prosthesis for pediatric distal femur malignancies; (2) the complications associated with this prosthesis; (3) the failure rate of this prosthesis; and (4) the revision alternatives available for salvage procedures. Between 2002 and 2010, one surgeon (SG) treated all skeletally immature patients (mean age, 10.1 years; range, 4.7-13.6 years) with distal femoral osteosarcoma using a Repiphysis expandable prosthesis. Of the 12 patients who met these criteria, two were excluded for death from disease before 2 years, and mean followup for the remaining 10 was 72 months (range, 26-119 months). Medical records were retrospectively reviewed for complications and clinical outcomes, as assessed by the Musculoskeletal Tumor Society (MSTS) scoring system. Radiographs at final followup were reviewed for bone loss and analyzed by the two senior authors (SG, WWV) to determine reconstruction options available for future revisions. MSTS scores averaged 67%, and we observed 37 implant-related complications requiring a total of 15 reoperations. Six patients underwent implant revisions with aseptic loosening being the predominant mode of failure; ultimately, four of these were converted to adult modular oncology prostheses, and two underwent total femoral replacements. Bone loss in this series was severe in terms of femoral length, cortical thinning, and metadiaphyseal compromise, and most patients will not have sufficient bone stock to permit

  9. Unusual way of loosened total hip arthroplasty treatment with an Austin Moore endoprosthesis.

    Science.gov (United States)

    Erceg, M; Becic, K

    2014-01-01

    A 65-year-old female patient with aseptic loosening of total cemented hip endoprosthesis and pathologic fracture of the femur at the level of the stem of endoprosthesis was presented. As no appropriate endoprosthesis was available due to the war in Croatia and war priority, the problem was managed by femur osteosynthesis and implantation of a partial Austin Moore hip endoprosthesis. The endoprosthesis is still functioning well (for 20 years).To the best of the author's knowledge, nobody has ever treated problem like this using this alternative, an unconventional method, with an Austin Moore endoprosthesis.

  10. Antigranulocyte scintigraphy of septic loosening of hip prosthesis: influence of different analyzing methods; Antigranulozytenszintigraphie bei septischer Hueft-Endoprothesen-Lockerung: Einfluss unterschiedlicher Auswertemethoden

    Energy Technology Data Exchange (ETDEWEB)

    Klett, R.; Steiner, D.; Puille, M.; Khalisi, A.; Bauer, R. [Giessen Univ. (Germany). Klinik fuer Nuklearmedizin; Matter, H.P.; Stuerz, H. [Giessen Univ. (Germany). Orthopaedische Klinik

    2001-06-01

    Diagnosis of infection with help of antigranulocyte scintigraphy near body stem is difficult because of contemporary visualisation of bone marrow. Therefore, we investigated, whether it is possible to improve the accuracy in diagnosing septic loosening of hip endoprosthesis by changing the analyzing methods. Methods: In 28 patients, the results of a visual interpretation of late scan, a visual interpretation and a quantitative interpretation of time-activity-course were compared. These results were verified by histology respectively microbiology. Results: Histological and microbiological verification found 14 septic loosening and 14 aseptic loosening of the hip protheses. Therefore, sensitivity, specificity, negative and positive predictive value for the visual interpretation of late scan were 0.86, 0.57, 0.80 and 0.67. For visual and quantitative interpretation of time-activity-course we found 0.86, 0.79, 0.85 and 0.80 respectively 1, 0.93, 1, 0.93. For interobserver agreement we found kappa coefficients of 0.28 {+-} 0.2 for visual interpretation of late scan, 0.48 {+-} 0.17 for visual interpretation and 1.0 {+-} 0 for quantitative interpretation of time-activity-course. Conclusion: In all investigated values quantitative interpretation of time-activity-course was superior to the other analyzing methods. Therefore, antigranulocyte scintigraphy for septic loosening of hip endoprosthesis should be interpreted quantitatively. (orig.) [German] Bei der Entzuendungsdiagnostik mittels Antigranulozytenszintigraphie ergeben sich in der Naehe des Koerperstammes aufgrund der gleichzeitigen Knochenmarkdarstellung Beurteilungsschwierigkeiten, da nicht immer sicher zwischen entzuendlichen Fokus beziehungsweise Knochenmark zu unterscheiden ist. Es wurde daher untersucht, ob bei der Diagnostik der septischen Hueft-Endoprothesen-Lockerung durch Aenderung des Auswerteverfahrens eine Verbesserung der Aussage zu erzielen ist. Methode: Bei 28 Patienten wurden die Ergebnisse einer

  11. Diagnostic value of bone scintigraphy with sup(99m)Tc-pyrophosphate for evaluation of complications after hip joint replacement

    International Nuclear Information System (INIS)

    Baumer, J.F.

    1979-01-01

    For 102 patients with complaints after total hip replacement, bone scintigraphies with sup(99m)Tc have been made in addition to the usual examinations. 95 of these patients had to be operated once more, whereas the infected endoprosteses detected in the remaining 7 patients have been treated for the time being by non-surgical measures. In 68 patients, the examination revealed an aseptic loosening of the total endoprosthesis, including fracture of the diaphysis in 19 cases. In one case, a replacement of the prosthesis had been necessary in spite of the alloarthroplasty being firmly fixed in the right place. The bacterioscopic and bacteriologic investigations clearly revealed an infection of the environment of the prosthesis, in 27 patients, whereas the findings obtained on 6 other patients have not been as unambiguons. 85% of the patients with septic complications showed an increased E.S.R., however only 26% of the patients with aseptic complications. In only 47% of the patients with infection of the hip joint, bacteria have been found in the hip joint puncture fluid, whereas the bacteriological examination of tissue taken from the environment of the artificial hip joint during the operation revealed no increase in bacteria in only one case (5%). In 4 patients (20%), the bacterioscopic findings showed no signs of an acute infection, although saprophytic germs had been isolated from the environment of the prosthesis. 78% of the cases with loosening of the prosthesis and 11% of the infections have been detected by X-ray examination. The nuclear medical examination showed normal radionuclide accumulation in 30% of the cases with loosened prosthesis and in 4% of the infections, for 6% each of the two complications the scintigrams yielded no unambiguous results. In 4 patients (40%) with total hip joint replacement on both sides, enhanced radionuclide accumulation has been abserved even on the symptom-free side. (orig./AJ) [de

  12. Unusual way of loosened total hip arthroplasty treatment with an Austin Moore endoprosthesis

    Directory of Open Access Journals (Sweden)

    M Erceg

    2014-01-01

    Full Text Available A 65-year-old female patient with aseptic loosening of total cemented hip endoprosthesis and pathologic fracture of the femur at the level of the stem of endoprosthesis was presented. As no appropriate endoprosthesis was available due to the war in Croatia and war priority, the problem was managed by femur osteosynthesis and implantation of a partial Austin Moore hip endoprosthesis. The endoprosthesis is still functioning well (for 20 years.To the best of the author′s knowledge, nobody has ever treated problem like this using this alternative, an unconventional method, with an Austin Moore endoprosthesis.

  13. Radionuclide arthrogram to evaluate knee prostheses loosening

    International Nuclear Information System (INIS)

    Ahn, U.

    2009-01-01

    Full text:This case is about a 78 year old lady who had 3TKRs on her left knee. The 2nd revision surgery was performed due to infection. After 6 weeks long procedure, that patient was discharged with satisfactory movement without sign of infection. 15 months after the surgery, the orthopaedic surgeon found that some pressure wave effects and pain with walking. There was no sign of infection clinically. Once X-ray could not confirm any micro-loosening, the surgeon wanted to investigate with radionuclide arthrogram for this difficult case. 40 MBq in 2mls of Calcium phytate colloid (from RADPHARM Australia) was injected into the knee joint space. 30 minutes static views revealed the tracer started to travel below the tibial component. 4 hours statics views clearly indicate the tibial component loosening also there was leakage of tracer through anterior tibial osteotomy screws into the level of ankle subcutaneously. Cobalt57 flood images provided the anatomical localisation. While the surgeon was planning new component for the 3rd revision surgery, the patient's pain disappeared with time. No more revision was considered with satisfactory level of movement. This was the first and only case of radio arthogram to our department, although we perform many bone scans with same reason. On published articles, overall sensitivity and specificity are variable from 85% to 100%. When we take look at other clinical experience, there are a number of reasons in the high accuracy and reliability of radionuclide arthrogram especially for knee prosthesis loosening. Therefore I want to emphasise the benefit of radionuclide arthrogram for both patient and surgeon as a reliable diagnosis with minimum discomfort.

  14. Imaging of hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Theodore T., E-mail: millertt@hss.edu [Department of Radiology and Imaging, Hospital for Special Surgery, 535 E. 70th Street, New York, NY 10021 (United States)

    2012-12-15

    The imaging evaluation of the prosthetic hip begins with radiography, but arthrography, aspiration, scintigraphy, sonography, CT and MR imaging all have roles in the evaluation of the painful prosthesis. This article will review the appearance of normal hip arthroplasty including hemiarthroplasty, total arthroplasty, and hip resurfacing, as well as the appearances of potential complications such as aseptic loosening and osteolysis, dislocation, infection, periprosthetic fracture, hardware failure, and soft tissue abnormalities.

  15. Failure of aseptic revision total knee arthroplasties.

    Science.gov (United States)

    Leta, Tesfaye H; Lygre, Stein Håkon L; Skredderstuen, Arne; Hallan, Geir; Furnes, Ove

    2015-02-01

    In Norway, the proportion of revision knee arthroplasties increased from 6.9% in 1994 to 8.5% in 2011. However, there is limited information on the epidemiology and causes of subsequent failure of revision knee arthroplasty. We therefore studied survival rate and determined the modes of failure of aseptic revision total knee arthroplasties. This study was based on 1,016 aseptic revision total knee arthroplasties reported to the Norwegian Arthroplasty Register between 1994 and 2011. Revisions done for infections were not included. Kaplan-Meier and Cox regression analyses were used to assess the survival rate and the relative risk of re-revision with all causes of re-revision as endpoint. 145 knees failed after revision total knee arthroplasty. Deep infection was the most frequent cause of re-revision (28%), followed by instability (26%), loose tibial component (17%), and pain (10%). The cumulative survival rate for revision total knee arthroplasties was 85% at 5 years, 78% at 10 years, and 71% at 15 years. Revision total knee arthroplasties with exchange of the femoral or tibial component exclusively had a higher risk of re-revision (RR = 1.7) than those with exchange of the whole prosthesis. The risk of re-revision was higher for men (RR = 2.0) and for patients aged less than 60 years (RR = 1.6). In terms of implant survival, revision of the whole implant was better than revision of 1 component only. Young age and male sex were risk factors for re-revision. Deep infection was the most frequent cause of failure of revision of aseptic total knee arthroplasties.

  16. Metabolic Pattern of Asymptomatic Hip-Prosthesis by 18F-FDG-Positron-Emission-Tomography

    International Nuclear Information System (INIS)

    Beslic, Nermina; Heber, Daniel; Walter Lipp, Rainer; Sonneck-Koenne, Charlotte; Knoll, Peter; Mirzaei, Siroos

    2015-01-01

    Joint replacement is a procedure with a major impact on the quality of life of patients with joint degenerative disease or traumatic injuries. However, some patients develop symptoms after the intervention caused by mechanical loosening or infection. Metabolic imaging by 18F-FDG-PET investigated in these patients isoften hampered by low specificity for diagnosis of possible septic vs. mechanical loosening. The reason for this shortcoming is to our opinion the unawareness of physiological remodeling processes that could be seen in asymptomatic patients. In order to overcome this drawback, we aimed to find out the physiological metabolic functional pattern in asymptomatic patients with implanted hip prosthesis Twelve patients (6 males, 6 females); mean age 73 ± 7 (range 58 - 91) years were prospectively enrolled in the study. The patients were admitted to our department for oncological referral with implanted hip prostheses. All patients explained no symptoms with regard to their implanted prosthesis. The attenuation corrected images were used for analysis. Fourteen hip prostheses in 12 patients were visually analyzed. Seven out of 14 prostheses among 12 patients showed focal periprosthetic enhanced metabolism, two of which showed two sites of enhanced uptake; whereas, the remaining five prostheses showed singular hypermetabolic areas within the periprosthetic site. The remaining seven prostheses in the other five patients showed no periprosthetic-enhanced uptake. Of the asymptomatic patients investigated, 58% showed focal enhanced periprosthetic glucose metabolism. This finding should be taken into consideration as a more probable unspecific metabolic pattern for correct interpretation of 18F-FDG-PET studies in patients with suspected septic loosening of the hip prosthesis

  17. [Study of friction and loosening in hip endoprostheses].

    Science.gov (United States)

    Dovzak Bajs, Ivana; Cvjetko, Ivan; Car, Dolores; Kokić, Visnja

    2002-01-01

    Like any other operative procedure, the implantation of hip prosthesis is associated with certain complications, which diminishes the value and purpose of such a procedure. One of the complications in artificial hip implantation is loosening of the alloplastic material. Therefore, the aim of this study was to examine the effect of lubrication on the torsional moment and its role in the loosening of the femoral component, using an experimental mechanical model. The following hypothesis was tested: the magnitude of torsional loading in the "bone-endoprosthesis-bone cement system" is similar to any other known loading. The testing device was constructed with the possibility of simulation of positions similar to original performances in the implanted hip prosthesis. It refers primarily to the possibilities of achieving definite forces and velocities. The intention was to point quantitatively to the role of friction moment between the acetabular and femoral endoprosthesis part. Trials were conducted by combining 7 types of loading and 4 kinds of lubrication: dry, water, plasma, and light oil. The testing joint (Ring's prosthesis) was connected through tensometric measuring shaft upon the working forepart oscillating mechanism. Graded by the changeable static loading by means of the pendulum and via lever mechanism the testing joint was loaded by force from 610 to 7137 N. As the cause of friction resistance in the moving joint, torque deformaties of the measuring shaft occurred. The testing joint enabled oscillating movement using a four-part mechanism. In this way, it was possible to define not only the maximum values of the frictional moment (or the coefficient of friction) during one movement cycle but also to examine its relation to the kind of lubrication. Change in the measuring torsional moment were computer recorded. Before each trial, the gauging of the complete outfit was performed. Thereafter, cleaning of the frictional surfaces of the whole outfit was done

  18. Cyclooxygenase-2 inhibitors and knee prosthesis surgery

    OpenAIRE

    Meunier, Andreas

    2008-01-01

    Adverse effects of cyclooxygenase (COX) inhibitors on bone healing have previously been demonstrated in diaphyseal fracture models in animals. In spite of that, they are widely used as postoperative analgesics in orthopaedic surgery. After joint replacement, a bone repair process starts at the interface between bone and cement. If this process is disturbed, the prosthesis may never become rigidly fixed to the bone, leading to migration and with time loosening. This thesis investigates the eff...

  19. Radionuclide arthrogram with SPECT/CT for the evaluation of mechanical loosening of hip and knee prostheses

    International Nuclear Information System (INIS)

    Chew, C.G.; Lewis, P.; Middleton, F.; Wijngaard, R. van den; Deshaies, A.

    2010-01-01

    The Objective of this study was to evaluate the value of single photon emission computed tomography (SPECT)/CT in radionuclide arthrogram (RNA) for the assessment of mechanical loosening of hip and knee prostheses. A retrospective audit of 117 RNA SPECT/CTs evaluated by a single reader- 40 hips, (1 hemiarthroplasty) and 77 knees (12 unicompartmental). The detection of any radiotracer within the bone/prosthetic interface was deemed positive for loosening. The operative assessment of 29 hip and 44 knee prosthetic joints was known and used as the gold standard. A subsequent blinded reassessment of the planar images was performed and compared with the SPECT/CT results for 26 of the 29 hip and 42 of the 44 knee prostheses. The respective SPECT/CT versus planar results were as follows: hips- acetabular cup: sensitivity: 73 versus 0%; specificity: 71 versus 100%; positive predictive value: 62% versus indeterminate; negative predictive value: 80% versus 72% (p=0.0044). Hips- femoral component: sensitivity: 78 versus 63%; specificity: 90 versus 94%; positive predictive value: 78 versus 83%; negative predictive value: 90 versus 85% (p=0.2482). Knees- femoral component: sensitivity: 75 versus 17%; specificity 63 versus 97%; positive predictive value: 43 versus 67%; negative predictive value: 87 versus 74% (p=0.0001). Knees- tibial component: sensitivity: 86 versus 63%; specificity: 86 versus 76%; positive predictive value: 55 versus 38%; negative predictive value: 97 versus 90% (p=0.6831). For evaluation of mechanical loosening of the hip prosthesis SPECT/CT was significantly better than planar scanning for the acetabular cup, but not for the femoral stem. For evaluation of the knee prosthesis, a significant improvement was noted using SPECT/CT for the femoral component, and although superior results were also noted for the tibial component, statistical significance was not reached. Taking into account the limitations of this retrospective audit, the value of using RNA SPECT

  20. Numerical evaluation of bone remodelling and adaptation considering different hip prosthesis designs.

    Science.gov (United States)

    Levadnyi, Ievgen; Awrejcewicz, Jan; Gubaua, José Eduardo; Pereira, Jucélio Tomás

    2017-12-01

    The change in mechanical properties of femoral cortical bone tissue surrounding the stem of the hip endoprosthesis is one of the causes of implant instability. We present an analysis used to determine the best conditions for long-term functioning of the bone-implant system, which will lead to improvement of treatment results. In the present paper, a finite element method coupled with a bone remodelling model is used to evaluate how different three-dimensional prosthesis models influence distribution of the density of bone tissue. The remodelling process begins after the density field is obtained from a computed tomography scan. Then, an isotropic Stanford model is employed to solve the bone remodelling process and verify bone tissue adaptation in relation to different prosthesis models. The study results show that the long-stem models tend not to transmit loads to proximal regions of bone, which causes the stress-shielding effect. Short stems or application in the calcar region provide a favourable environment for transfer of loads to the proximal region, which allows for maintenance of bone density and, in some cases, for a positive variation, which causes absence of the aseptic loosening of an implant. In the case of hip resurfacing, bone mineral density changes slightly and is closest to an intact femur. Installation of an implant modifies density distribution and stress field in the bone. Thus, bone tissue is stimulated in a different way than before total hip replacement, which evidences Wolff's law, according to which bone tissue adapts itself to the loads imposed on it. The results suggest that potential stress shielding in the proximal femur and cortical hypertrophy in the distal femur may, in part, be reduced through the use of shorter stems, instead of long ones, provided stem fixation is adequate. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Impact of UHMWPE texture on friction and wear resistance of hip prosthesis

    Directory of Open Access Journals (Sweden)

    Eddoumy Fatima

    2013-11-01

    Full Text Available Ultra High Molecular Weight PolyEthylene (UHMWPE is a polymer widely used in hip implants (prostheses as a bearing surface against metal, because of its good mechanical properties and biocompatibility [1]. Nevertheless, the durability of such implants is limited because of failure resulting from osteolysis and aseptic loosening. These two phenomenons are due to the immune response of human body consecutive to the apparition of wear particles of UHMWPE with time.

  2. Total Hip Arthroplasty Loosening Due to Mycobacterium Tuberculosis: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Anis Tebourbi

    2017-04-01

    Full Text Available Context: Prosthetic joint infection due to Mycobacterium tuberculosis with no previous history of pulmonary or extra pulmonary tuberculosis is an extremely rare complication. Aims To report the case of a patient with tuberculous mycobacterial prosthetic hip infection, 14 years after surgery for post traumatic osteoarthritis, with no previous history of tuberculosis. Methods A 46-year-old male presented an acetabular loosening of a cemented total hip arthroplasty with subnormal biologic parameters. A one stage revision surgery was planned. Intraoperative findings suggested mycobacterial tuberculous infection with presence of periacetabular yellowish rice-shaped granules. Results A one-stage prosthesis exchange was performed; Culture on Löwenstein-Jensen medium grew MTB days after inoculation and histological examination confirmed tuberculous infection. Patient was treated by antituberculous agents for 12 months with optimal clinical and biological response and no prosthetic loosening signs at eighteen months follow up. Conclusions Total hip arthroplasty loosening due to mycobacterium tuberculosis is a rare entity, which should be evoked even when no inflammatory signs are shown. Discovery of yellowish rice-shaped granules is an indicator to investigate for tuberculosis. Management of prosthetic joint infection due to M.tuberculosis must involve both medical and surgical approach.

  3. Simulation of the filtration mechanism of hyaluronic acid in total knee prosthesis

    International Nuclear Information System (INIS)

    Paolo, J Di; Berli, M E; Campana, D M; Ubal, S; Cardenes, L D

    2007-01-01

    Polyethylene (UHMWPE) wear in current knee prosthesis causes prosthesis loosening after no more than 15 years. In this work, a steady state one-dimensional lubrication model with non- Newtonian fluid, porous elastic layer on tibial component, ultra-filtration mechanism of fluid and some features of the surface roughness is studied through a numerical technique based on the Finite Element Method. The results show that the UHMWPE stiffness makes difficult the lubrication mechanism of the artificial joint and promotes abrasive and fatigue wear. Nevertheless, the use of compliant porous materials on the tibial component could reduce friction and wear. Moreover, the ultra-filtration mechanism promotes efficiency on the joint

  4. [PVD-silicoating before cementation of zirconia-based knee prostheses effects better cement adhesion and lower aseptic loosening rates].

    Science.gov (United States)

    Marx, R; Faramarzi, R; Oberbach, T; Begand, S; Grätz, N; Wirtz, D C

    2012-02-01

    CoCrMo alloys are contraindicated for allergy patients. For these patients, cemented or uncemented prostheses made of titanium alloy are indicated. Uncemented prostheses, however, have low primary retention, particularly the tibial components of knee joint prostheses because of the lack of a positive locking. Therefore, for knee replacement cemented CoCrMo prostheses may be suitable also for allergy sufferers if these are masked by ZrN or TiNbN layers. Alternatively the CoCrMo alloy may be replaced by high-strength oxide ceramics. For adhesion of bone cement to the ceramic surface, however, only inefficient mechanical retention spots are exposed as compared with a metal surface. Undercuts generated by corundum blasting, although highly efficient on a CoCrMo surface, are not such efficient centres on a ceramic surface due to its brittleness. Therefore, the mechanical component of retention is significantly reduced. When specific adhesion between bone cement and surface does not exist due to physical and chemical forces, the hydrolytic stability will be insufficient. Micromotions are promoted and early aseptic loosening is predictable. Silicoating of the ceramic surface will allow specific adhesion and can result in better hydrolytic stability of bonding. In order to evaluate the effectiveness of silicoating the bond strengths of blasted (mean size of corundum grains 50 µm) and silicate layered alumina-toughened zirconia (ATZ) surfaces were compared with "as fired" surfaces by utilising TiAlV probes (diameter 6 mm) for traction-adhesive strength testing. Samples machined out of CoCrMo alloy were utilised for reference. After preparing the samples for traction-adhesive strength testing (sequence: substrate, silicate and silane, protective lacquer [PolyMA], bone cement, TiAlV probe) they were aged up to 360 days at 37 °C in Ringer's solution. The bond strengths observed for all ageing intervals were well above 20 MPa and much higher and more hydrolytically

  5. Ultrastructural analysis of nanoparticles and ions released in periprosthetic membranes.

    Science.gov (United States)

    Sabbatini, Maurizio; Gatti, Giorgio; Renò, Filippo; Bosetti, Michela; Marchese, Leonardo; Cannas, Mario

    2014-12-30

    The distribution and relationship of hydroxyapatite debris, nanometric organic and metal wear particles and metal ions on periimplant interface membranes following aseptic and septic arthroplastic loosening were investigated. Scanning electron microscopy and X-ray spectroscopic analysis were used to analyze debris and ion distribution. Hydroxyapatite debris appeared with different morphology in a particular distribution among several membranes. These differences may reflect the occurrence of different friction forces taking place between prosthesis and bone interface in the several types of prostheses studied. Metal wear particles were detected in greater numbers in membranes from noncemented prostheses compared with those from cemented ones. In contrast, more organic particles were present in membrane from cemented prosthesis. No differences were observed between aseptic and septic membranes. Our findings support the need to evaluate the occurrence of friction forces that periprosthetic bone debris production may induce to exacerbate cellular reactivity. Furthermore, cellular engulfment of debris and the high level of different ions released indicate the occurrence of a toxic environment that may induce failure of any reparative pathways.

  6. Immunoscintigraphy with antigranulocyte monoclonal antibodies for the diagnosis of septic loosening of hip prostheses

    International Nuclear Information System (INIS)

    Boubaker, A.; Bischof Delaloye, A.; Blanc, C.H.; Dutoit, M.; Leyvraz, P.F.; Delaloye, B.

    1995-01-01

    To determine the value of immunoscintigraphy (IS) with antigranulocyte monoclonal antibodies (Mab) in the diagnosis of subacute or chronic infection of hip prostheses, we prospectively studied 57 patients (23 women and 34 men; age 29-92 years, mean 72.7 years) sent to our institution in the past 6 years for clinical suspicion of septic loosening of a hip prosthesis. Nineteen patients had bilateral prostheses and one of them was studied twice. A total of 78 prostheses were examined. All patients had three-phase bone scans followed by IS with technetium-99m antigranulocyte Mab BW 250/183. Intervals between bone scans and IS varied from 2 days to 4 weeks. Final diagnosis was assessed by culture in 48 cases (articular puncture or intraoperative sampling) and by clinical follow-up of at least 8 months in 30 cases. Twelve prostheses were considered septic and 66 non-septic. The overall sensitivity and specificity were 92% and 64% respectively for bone scans, 67% and 75% for IS and 67% and 84% for both modalities together. In three cases, IS was doubtful and the final clinical diagnosis was negative for infection. False-positive results were observed in the presence of massive loosening of the prosthesis or in association with metaplastic peri-articular bone formation. In three of the four false-negative results, infection was proven only after enrichment of the culture, and the bacterium was Staphylococcus epidermidis. In 12/33 (36%) positive bone scans IS allowed the diagnosis of infection to be excluded. Overall accuracy of both modalities together was 81% and the negative predictive value was 93%, which compares favourably with the results reported for other non-invasive methods. (orig.)

  7. Assessment of suspected infection of hip or knee endoprosthesis by nuclear medicine techniques; Nuklearmedizinische Abklaerung bei vermuteter Infektion einer Hueft- oder Knie-TEP

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, M.; Dietlein, M.; Schicha, H. [Koeln Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin; Delank, K.S. [Koeln Univ. (Germany). Klinik und Poliklinik fuer Orthopaedie

    2007-06-15

    Complications after hip endoprosthesis operation occur with a frequency of 1-2 % after primary operation and with 3-5 % after revision arthroplasty and are even more frequent after knee arthroplasty. The differentiation between aseptic loosening and bacterial infection is very important. In aseptic loosening a one-step revision is usually possible. In case of bacterial infection, all foreign material has to be removed first to allow cure from the infection. After healing and absence of bacteria a follow-up operation is possible with insertion of a new prosthesis. Diagnosis and therapy of a painful hip or knee endoprosthesis are difficult, because patient history, clinical examination, laboratory results including microbiological investigation of puncture material and results of radiological examinations may all be inconclusive. Quite a number of nuclear medicine procedures have been published in the past to help in the differentiation between aseptic loosening and bacterial infection of a painful hip or knee endoprosthesis. No single method can be regarded as excellent and without disadvantages. In the international literature the combined leucocyte-marrow imaging has been propageted as superior technique. In Germany, combined leucocyte-marrow imaging is not available in the published form. Moreover, this technique is time consuming, cost intensive and requires direct work with blood. Therefore, infection imaging with labelled antibodies or labelled fragments of antibodies may be regarded as the method of choice for most nuclear medicine physicians. With semiquantitative evaluation a comparative diagnostic accuracy may be achieved. {sup 18}F-FDG-PET is not able to differentiate reliably between abacterial polyethylene abrasion and septic inflammation. However, with pattern recognition of the distribution of {sup 18}F-FDG around a hip prosthesis an approach with clinically acceptable results has been published. A normal {sup 18}F-FDG-PET can reliably exclude an

  8. Assessment of suspected infection of hip or knee endoprosthesis by nuclear medicine techniques

    International Nuclear Information System (INIS)

    Schmidt, M.; Dietlein, M.; Schicha, H.; Delank, K.S.

    2007-01-01

    Complications after hip endoprosthesis operation occur with a frequency of 1-2 % after primary operation and with 3-5 % after revision arthroplasty and are even more frequent after knee arthroplasty. The differentiation between aseptic loosening and bacterial infection is very important. In aseptic loosening a one-step revision is usually possible. In case of bacterial infection, all foreign material has to be removed first to allow cure from the infection. After healing and absence of bacteria a follow-up operation is possible with insertion of a new prosthesis. Diagnosis and therapy of a painful hip or knee endoprosthesis are difficult, because patient history, clinical examination, laboratory results including microbiological investigation of puncture material and results of radiological examinations may all be inconclusive. Quite a number of nuclear medicine procedures have been published in the past to help in the differentiation between aseptic loosening and bacterial infection of a painful hip or knee endoprosthesis. No single method can be regarded as excellent and without disadvantages. In the international literature the combined leucocyte-marrow imaging has been propageted as superior technique. In Germany, combined leucocyte-marrow imaging is not available in the published form. Moreover, this technique is time consuming, cost intensive and requires direct work with blood. Therefore, infection imaging with labelled antibodies or labelled fragments of antibodies may be regarded as the method of choice for most nuclear medicine physicians. With semiquantitative evaluation a comparative diagnostic accuracy may be achieved. 18 F-FDG-PET is not able to differentiate reliably between abacterial polyethylene abrasion and septic inflammation. However, with pattern recognition of the distribution of 18 F-FDG around a hip prosthesis an approach with clinically acceptable results has been published. A normal 18 F-FDG-PET can reliably exclude an infection

  9. The Utility of Digital Linear Tomosynthesis Imaging of Total Hip Joint Arthroplasty with Suspicion of Loosening: A Prospective Study in 40 Patients

    Science.gov (United States)

    Göthlin, Jan H.

    2013-01-01

    Aim. The clinical utility of digital linear tomosynthesis in musculoskeletal applications has been validated in only a few reports. Technical performance and utility in hip prosthesis imaging have been discussed in technical reports, but no clinical evaluation has been reported. The purpose of the current study was to assess the added clinical utility of digital linear tomosynthesis compared to radiography in loosening of total hip joint arthroplasty. Materials and Methods. In a prospective study, radiography and digital tomosynthesis were performed in 40 consecutive patients with total hip arthroplasty referred for suspect prosthesis loosening. Tomosynthesis images were compared to anterior-posterior (AP) and cross-table lateral radiographs regarding demarcation and extent of demineralization and osteolysis. Further noted were skeletal fractures, cement fractures, fragmentation, and artifacts interfering with the diagnosis. Results. Tomosynthesis was superior to radiography with sharper delineation of demineralization and osteolysis in the AP projection. A limitation was the inability to generate lateral tomosynthesis images, with inferior assessment of the area anterior and posterior to the acetabular cup compared to cross-table radiographs. Artifacts interfering with diagnosis were found in one hip. Conclusion. Tomosynthesis improved evaluation of total hip arthroplasty in the AP projection but was limited by the lack of lateral projections. PMID:24078921

  10. The Utility of Digital Linear Tomosynthesis Imaging of Total Hip Joint Arthroplasty with Suspicion of Loosening: A Prospective Study in 40 Patients

    Directory of Open Access Journals (Sweden)

    Jan H. Göthlin

    2013-01-01

    Full Text Available Aim. The clinical utility of digital linear tomosynthesis in musculoskeletal applications has been validated in only a few reports. Technical performance and utility in hip prosthesis imaging have been discussed in technical reports, but no clinical evaluation has been reported. The purpose of the current study was to assess the added clinical utility of digital linear tomosynthesis compared to radiography in loosening of total hip joint arthroplasty. Materials and Methods. In a prospective study, radiography and digital tomosynthesis were performed in 40 consecutive patients with total hip arthroplasty referred for suspect prosthesis loosening. Tomosynthesis images were compared to anterior-posterior (AP and cross-table lateral radiographs regarding demarcation and extent of demineralization and osteolysis. Further noted were skeletal fractures, cement fractures, fragmentation, and artifacts interfering with the diagnosis. Results. Tomosynthesis was superior to radiography with sharper delineation of demineralization and osteolysis in the AP projection. A limitation was the inability to generate lateral tomosynthesis images, with inferior assessment of the area anterior and posterior to the acetabular cup compared to cross-table radiographs. Artifacts interfering with diagnosis were found in one hip. Conclusion. Tomosynthesis improved evaluation of total hip arthroplasty in the AP projection but was limited by the lack of lateral projections.

  11. Uncemented three-dimensional-printed prosthetic replacement for giant cell tumor of distal radius: a new design of prosthesis and surgical techniques

    Directory of Open Access Journals (Sweden)

    Lu MX

    2018-02-01

    Full Text Available Minxun Lu,* Li Min,* Cong Xiao, Yongjiang Li, Yi Luo, Yong Zhou, Wenli Zhang, Chongqi Tu Department of Orthopedics, West China Hospital, Sichuan University, Chengdu, Sichuan, People’s Republic of China *These authors contributed equally to this work Introduction: Currently, it is challenging to treat giant cell tumor (GCT of distal radius. For Campanacci grade III or recurrent GCTs, en bloc resection has been accepted as a better treatment option. Although numerous methods are available for reconstruction, all of them have some limitations in joint function and complications. In this study, our aims were to treat the GCT of distal radius with uncemented three-dimensional (3D-printed prosthesis and to present and evaluate the surgical techniques and short-term outcomes. Methods: Between September 2015 and March 2017, 11 patients with distal radius GCTs were treated with personalized uncemented 3D-printed prosthesis. The preoperative/postoperative pain, range of motion, and grip strengths of all patients were evaluated. Oncological results, complications, and degenerative changes in the wrist joint were evaluated. Functional outcomes were assessed according to the disabilities of the arm, shoulder, and hand (DASH questionnaire and Mayo wrist scoring systems. Results: The average follow-up was 14.45 months (range, 8–18 months. There was a significant decrease in the mean postoperative visual analog scale score (2.33 compared with the preoperative score (5.22; p<0.001. The mean DASH score and Mayo wrist score of the wrist joint function were 18.7 and 72, respectively. There was no local recurrence or lung metastasis. No complication associated with prosthesis was observed, including aseptic loosening, subluxation, and breakage. Joint space narrowing, or disuse osteoporosis, was also not found in all cases. Conclusion: En bloc resection and reconstruction with a personalized uncemented 3D-printed prosthesis can be alternative options to

  12. Analysis of a retrieved delta III total shoulder prosthesis.

    Science.gov (United States)

    Nyffeler, R W; Werner, C M L; Simmen, B R; Gerber, C

    2004-11-01

    A reversed Delta III total shoulder prosthesis was retrieved post-mortem, eight months after implantation. A significant notch was evident at the inferior pole of the scapular neck which extended beyond the inferior fixation screw. This bone loss was associated with a corresponding, erosive defect of the polyethylene cup. Histological examination revealed a chronic foreign-body reaction in the joint capsule. There were, however, no histological signs of loosening of the glenoid base plate and the stability of the prosthetic articulation was only slightly reduced by the eroded rim of the cup.

  13. Atraumatic patellar prosthesis dislocation with patellar tendon injury following a total knee arthroplasty: a case report

    Directory of Open Access Journals (Sweden)

    Singh Alka

    2010-01-01

    Full Text Available Abstract Introduction Total knee arthroplasty is a well-established procedure with gratifying results. There is no consensus in the literature whether to routinely resurface the patella while performing total knee arthroplasty or not. Although an extremely rare occurrence in clinical practice, patellar prosthesis dislocation is a possible complication resulting from total knee arthroplasty. Case presentation We report a rare case of atraumatic spontaneous dislocation of patellar prosthesis in a 63-year-old Caucasian man of British origin with patellar tendon injury. The patient was treated successfully through a revision of the patellar component and tendon repair. In two years follow-up the patient is asymptomatic with no sign of loosening of his patellar prosthesis. Conclusions A thorough understanding of knee biomechanics is imperative in performing total knee arthroplasty in order to achieve a better functional outcome and to prevent early prosthetic failure.

  14. Aseptic techniques(practical guide no.3)

    International Nuclear Information System (INIS)

    Nappa, Andres; Souto Pais, Beatriz

    1994-01-01

    Definition of aseptic techniques in relation with the labor of Radiopharmacy.Control of environment and working areas.Control of materials entered into an aseptic area: water, nitrogen,vials,stoppers,needles and syringes. Personnel and manipulations control,choosing of materials,precautions in the aseptic manipulation and sterility preservation during usage life. Bacteriological membrane filtration in sterilized conditions. Work in a laminar flow unit. Protocol of Practical task 3. Bibliography

  15. Percutaneous bone cement refixation of aseptically loose hip prostheses: the effect of interface tissue removal on injected cement volumes

    Energy Technology Data Exchange (ETDEWEB)

    Malan, Daniel F. [Leiden University Medical Center, Department of Orthopaedics, Leiden (Netherlands); Delft University of Technology, Department of Intelligent Systems, Delft (Netherlands); Valstar, Edward R. [Leiden University Medical Center, Department of Orthopaedics, Leiden (Netherlands); Delft University of Technology, Department of Biomechanical Engineering, Delft (Netherlands); Nelissen, Rob G.H.H. [Leiden University Medical Center, Department of Orthopaedics, Leiden (Netherlands)

    2014-11-15

    To quantify whether injected cement volumes differed between two groups of patients who underwent experimental minimally invasive percutaneous cement injection procedures to stabilize aseptically loose hip prostheses. One patient group was preoperatively treated using gene-directed enzyme prodrug therapy to remove fibrous interface tissue, while the other group received no preoperative treatment. It was hypothesized that cement penetration may have been inhibited by the presence of fibrous interface tissue in periprosthetic lesions. We analyzed 17 patients (14 female, 3 male, ages 72-91, ASA categories 2-4) who were treated at our institution. Osteolytic lesions and injected cement were manually delineated using 3D CT image segmentation, and the deposition of injected cement was quantified. Patients who underwent preoperative gene-directed enzyme therapy to remove fibrous tissue exhibited larger injected cement volumes than those who did not. The observed median increase in injected cement volume was 6.8 ml. Higher cement leakage volumes were also observed for this group. We conclude that prior removal of periprosthetic fibrous interface tissue may enable better cement flow and penetration. This might lead to better refixation of aseptically loosened prostheses. (orig.)

  16. Cetuximab induced aseptic meningitis

    OpenAIRE

    Ulrich, A; Weiler, S; Weller, M; Rordorf, T; Tarnutzer, A A

    2015-01-01

    We report a 67-year-old man with recurrent advanced oropharyngeal squamous cell carcinoma who developed aseptic meningitis, with first symptoms arising approximately 9hours after the first administration of cetuximab, and review the literature to identify key signs and symptoms of this condition. Cetuximab is a monoclonal antibody targeting the epidermal growth factor receptor which has been rarely associated with aseptic meningitis. Besides the case description, a MEDLINE search was performe...

  17. Carbon/PEEK composite materials as an alternative for stainless steel/titanium hip prosthesis: a finite element study.

    Science.gov (United States)

    Rezaei, Farshid; Hassani, Kamran; Solhjoei, Nosratollah; Karimi, Alireza

    2015-12-01

    Total hip replacement (THR) has been ranked within the most typical surgical processes in the world. The durability of the prosthesis and loosening of prosthesis are the main concerns that mostly reported after THR surgeries. In THR, the femoral prosthesis can be fixed by either cement or cementless methods in the patient's bones. In both procedures, the stability of the prosthesis in the hosted bone has a key asset in its long-term durability and performance. This study aimed to execute a comparative finite element simulation to assess the load transfer between the prosthesis, which is made of carbon/PEEK composite and stainless steel/titanium, and the femur bone. The mechanical behavior of the cortical bone was assumed as a linear transverse isotropic while the spongy bone was modeled like a linear isotropic material. The implants were made of stainless steel (316L) and titanium alloy as they are common materials for implants. The results showed that the carbon/PEEK composites provide a flatter load transfer from the upper body to the leg compared to the stainless steel/titanium prosthesis. Furthermore, the results showed that the von Mises stress, principal stress, and the strain in the carbon/PEEK composites prosthesis were significantly lower than that made of the stainless steel/titanium. The results also imply that the carbon/PEEK composites can be applied to introduce a new optimum design for femoral prosthesis with adjustable stiffness, which can decrease the stress shielding and interface stress. These findings will help clinicians and biomedical experts to increase their knowledge about the hip replacement.

  18. Image Registration-Based Bolt Loosening Detection of Steel Joints

    Science.gov (United States)

    2018-01-01

    Self-loosening of bolts caused by repetitive loads and vibrations is one of the common defects that can weaken the structural integrity of bolted steel joints in civil structures. Many existing approaches for detecting loosening bolts are based on physical sensors and, hence, require extensive sensor deployment, which limit their abilities to cost-effectively detect loosened bolts in a large number of steel joints. Recently, computer vision-based structural health monitoring (SHM) technologies have demonstrated great potential for damage detection due to the benefits of being low cost, easy to deploy, and contactless. In this study, we propose a vision-based non-contact bolt loosening detection method that uses a consumer-grade digital camera. Two images of the monitored steel joint are first collected during different inspection periods and then aligned through two image registration processes. If the bolt experiences rotation between inspections, it will introduce differential features in the registration errors, serving as a good indicator for bolt loosening detection. The performance and robustness of this approach have been validated through a series of experimental investigations using three laboratory setups including a gusset plate on a cross frame, a column flange, and a girder web. The bolt loosening detection results are presented for easy interpretation such that informed decisions can be made about the detected loosened bolts. PMID:29597264

  19. Image Registration-Based Bolt Loosening Detection of Steel Joints.

    Science.gov (United States)

    Kong, Xiangxiong; Li, Jian

    2018-03-28

    Self-loosening of bolts caused by repetitive loads and vibrations is one of the common defects that can weaken the structural integrity of bolted steel joints in civil structures. Many existing approaches for detecting loosening bolts are based on physical sensors and, hence, require extensive sensor deployment, which limit their abilities to cost-effectively detect loosened bolts in a large number of steel joints. Recently, computer vision-based structural health monitoring (SHM) technologies have demonstrated great potential for damage detection due to the benefits of being low cost, easy to deploy, and contactless. In this study, we propose a vision-based non-contact bolt loosening detection method that uses a consumer-grade digital camera. Two images of the monitored steel joint are first collected during different inspection periods and then aligned through two image registration processes. If the bolt experiences rotation between inspections, it will introduce differential features in the registration errors, serving as a good indicator for bolt loosening detection. The performance and robustness of this approach have been validated through a series of experimental investigations using three laboratory setups including a gusset plate on a cross frame, a column flange, and a girder web. The bolt loosening detection results are presented for easy interpretation such that informed decisions can be made about the detected loosened bolts.

  20. Probiotics protect mice from CoCrMo particles-induced osteolysis

    Directory of Open Access Journals (Sweden)

    Wang Z

    2017-07-01

    Full Text Available Zhenheng Wang,* Kaiwen Xue,* Maosheng Bai, Zhantao Deng, Jingjing Gan, Gang Zhou, Hongbo Qian,* Nirong Bao, Jianning Zhao Department of Orthopaedics, Jinling Hospital, School of Medicine, Nanjing University, Nanjing, People’s Republic of China *These authors contributed equally to this work Abstract: Wear particle-induced inflammatory osteolysis is the primary cause of aseptic loosening, which is the most common reason for total hip arthroplasty (THA failure in the med- and long term. Recent studies have suggested an important role of gut microbiota (GM in modulating the host metabolism and immune system, leading to alterations in bone mass. Probiotic bacteria administered in adequate amounts can alter the composition of GM and confer health benefits to the host. Given the inflammatory osteolysis that occurs in wear debris-induced prosthesis loosening, we examined whether the probiotic Lactobacillus casei could reduce osteolysis in a mouse calvarial resorption model. In this study, L. casei markedly protected mice from CoCrMo particles (CoPs-induced osteolysis. Osteoclast gene markers and the number of osteoclasts were significantly decreased in L. casei-treated mice. Probiotic treatment decreased the M1-like macrophage phenotype indicated by downregulation of tumor necrosis factor α (TNF-α, interleukin (IL-6 and inducible nitric oxide synthase (iNOS and increased the M2-like macrophage phenotype indicated by upregulation of IL-4, IL-10 and arginase. Collectively, these results indicated that the L. casei treatment modulated the immune status and suppressed wear particle-induced osteolysis in vivo. Thus, probiotic treatment may represent a potential preventive and therapeutic approach to reduced wear debris-induced osteolysis. Keywords: wear particles, gut microbiota, nanotoxicity, macrophage polarization, inflammatory cytokines, aseptic loosening

  1. TOTAL ANKLE ARTHROPLASTY: BRAZILIAN EXPERIENCE WITH THE HINTEGRA PROSTHESIS.

    Science.gov (United States)

    Nery, Caio; Fernandes, Túlio Diniz; Réssio, Cibele; Fuchs, Mauro Luiz; Godoy Santos, Alexandre Leme de; Ortiz, Rafael Trevisan

    2010-01-01

    Ankle arthrosis is becoming more and more common. The search for solutions that preserve joint function has led to a new generation of prosthesis with three components and more degrees of freedom. This paper presents the results achieved for ten patients treated with the HINTEGRA Prosthesis (Integra, New Deal), through collaborative action between the Foot and Ankle Groups of the Orthopedics and Traumatology divisions of Escola Paulista de Medicina, Unifesp, and the School of Medicine of the University of São Paulo (USP). The ten patients (six women and four men, aged between 29 and 66 years), underwent a surgical procedure consisting of Hintermann's technique, between January and June 2005. They were evaluated at prearranged intervals, and the data were subjected to statistical analysis. The surgery led to a significant improvement in ankle mobility. Radiological evaluation showed no signs of loosening or failure in the prosthetic components in any of the patients studied. Although the complication rate in our sample was high, it was equivalent to the rates found by other authors, and directly represents the learning curve associate with this kind of procedure. Four years after the procedure, it was found that the patients pain levels had significantly decreased, and that their functional patterns had significantly improved, with AOFAS and Hintermann scores indicating results that were excellent for 20%, good for 70% and poor for 10%. Treatment of ankle arthritis by means of total arthroplasty using the HINTEGRA prosthesis was capable of providing good results over an average observation period of four years.

  2. Prosthetic joint infections: radionuclide state-of-the-art imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gemmel, Filip [AZ Alma Campus Sijsele, Department of Nuclear Medicine, Sijsele-Damme (Belgium); Wyngaert, Hans van den [AZ Alma Campus Sijsele, Department of Orthopaedic Surgery, Sijsele-Damme (Belgium); Love, Charito [Albert Einstein College of Medicine of Yeshiva University, Division of Nuclear Medicine and Radiology, Bronx, NY (United States); Welling, M.M. [Leiden University Medical Center, Scientist Molecular Imaging, Department of Radiology, Section of Nuclear Medicine C2-203, Leiden (Netherlands); Gemmel, Paul [Ghent University, The Faculty of Economics and Business Administration, Ghent (Belgium); Palestro, Christopher J. [Hofstra North Shore-Long Island Jewish Health System, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Hempstead, NY (United States)

    2012-05-15

    Prosthetic joint replacement surgery is performed with increasing frequency. Overall the incidence of prosthetic joint infection (PJI) and subsequently prosthesis revision failure is estimated to be between 1 and 3%. Differentiating infection from aseptic mechanical loosening, which is the most common cause of prosthetic failure, is especially important because of different types of therapeutic management. Despite a thorough patient history, physical examination, multiple diagnostic tests and complex algorithms, differentiating PJI from aseptic loosening remains challenging. Among imaging modalities, radiographs are neither sensitive nor specific and cross-sectional imaging techniques, such as computed tomography and magnetic resonance imaging, are limited by hardware-induced artefacts. Radionuclide imaging reflects functional rather than anatomical changes and is not hampered by the presence of a metallic joint prosthesis. As a result scintigraphy is currently the modality of choice in the investigation of suspected PJI. Unfortunately, there is no true consensus about the gold standard technique since there are several drawbacks and limitations inherent to each modality. Bone scintigraphy (BS) is sensitive for identifying the failed joint replacement, but cannot differentiate between infection and aseptic loosening. Combined bone/gallium scintigraphy (BS/GS) offers modest improvement over BS alone for diagnosing PJI. However, due to a number of drawbacks, BS/GS has generally been superseded by other techniques but it still may have a role in neutropenic patients. Radiolabelled leucocyte scintigraphy remains the gold standard technique for diagnosing neutrophil-mediated processes. It seems to be that combined in vitro labelled leucocyte/bone marrow scintigraphy (LS/BMS), with an accuracy of about 90%, is currently the imaging modality of choice for diagnosing PJI. There are, however, significant limitations using in vitro labelled leucocytes and considerable effort

  3. Prosthetic joint infections: radionuclide state-of-the-art imaging

    International Nuclear Information System (INIS)

    Gemmel, Filip; Wyngaert, Hans van den; Love, Charito; Welling, M.M.; Gemmel, Paul; Palestro, Christopher J.

    2012-01-01

    Prosthetic joint replacement surgery is performed with increasing frequency. Overall the incidence of prosthetic joint infection (PJI) and subsequently prosthesis revision failure is estimated to be between 1 and 3%. Differentiating infection from aseptic mechanical loosening, which is the most common cause of prosthetic failure, is especially important because of different types of therapeutic management. Despite a thorough patient history, physical examination, multiple diagnostic tests and complex algorithms, differentiating PJI from aseptic loosening remains challenging. Among imaging modalities, radiographs are neither sensitive nor specific and cross-sectional imaging techniques, such as computed tomography and magnetic resonance imaging, are limited by hardware-induced artefacts. Radionuclide imaging reflects functional rather than anatomical changes and is not hampered by the presence of a metallic joint prosthesis. As a result scintigraphy is currently the modality of choice in the investigation of suspected PJI. Unfortunately, there is no true consensus about the gold standard technique since there are several drawbacks and limitations inherent to each modality. Bone scintigraphy (BS) is sensitive for identifying the failed joint replacement, but cannot differentiate between infection and aseptic loosening. Combined bone/gallium scintigraphy (BS/GS) offers modest improvement over BS alone for diagnosing PJI. However, due to a number of drawbacks, BS/GS has generally been superseded by other techniques but it still may have a role in neutropenic patients. Radiolabelled leucocyte scintigraphy remains the gold standard technique for diagnosing neutrophil-mediated processes. It seems to be that combined in vitro labelled leucocyte/bone marrow scintigraphy (LS/BMS), with an accuracy of about 90%, is currently the imaging modality of choice for diagnosing PJI. There are, however, significant limitations using in vitro labelled leucocytes and considerable effort

  4. Development of an anti-loosening fastener and comparing its ...

    Indian Academy of Sciences (India)

    Bikash Panja

    2017-09-08

    Sep 8, 2017 ... MS received 13 November 2013; revised 20 June 2016; accepted 30 April ... However, threaded fasteners may have the problem of loosening under vibrating ..... [7] Junker G H 1969 New criteria for self-loosening of fasteners.

  5. Indications of 99mTc-MDP scintigraphy bone scan in the evaluation of painful hip arthroplasties

    International Nuclear Information System (INIS)

    Eder, V.; Baulieu, F.; Secchi, V.; Gautier, B.; Pottier, J.M.; Rosset, P.

    2000-01-01

    The purpose of this study was to determine the indication of bone scintigraphy in hip prosthesis complications. Thirty-six patients and 38 hip prosthesis have had a 99 Tc-MDP scintigraphy in our laboratory between 1995 and 1997. It concerns 32 cemented total prosthesis, 3 intermediate prosthesis and 3 non-cemented total prosthesis. For 14 prosthesis, complication (loosening or infection) was confirmed by surgical operation in 12 cases (4 isolated acetabular complications, 2 isolated femoral loosening, 3 global loosening and 3 infections) or by concordant data from different examinations in 2 cases (global loosening) where intervention was unrealizable. About other patients, absence of complication was confirmed by a favourable evolution lasting at least 12 months. A cetabular and femoral complications were detected by scintigraphy respectively with a sensitivity of 100 % and 90 %, a specificity of 85 % and 78 %, a PPV of 75 % and 60 % and NPV of 100 % and 96 %. High negative predictive value allows to eliminate a prosthesis complication in the case of a normal scintigraphy and to override decision when the clinic and the radiography are doubtful. Scintigraphy may recognize other bone fixation abnormalities which may be responsible of clinical symptomatology. (authors)

  6. Indications of {sup 99m}Tc-MDP scintigraphy bone scan in the evaluation of painful hip arthroplasties; Place actuelle de la scintigraphie osseuse dans l'evaluation des protheses de hanches douloureuses

    Energy Technology Data Exchange (ETDEWEB)

    Eder, V.; Baulieu, F.; Secchi, V.; Gautier, B.; Pottier, J.M. [Centre Hospitalier Universitaire, Sce de Medecine Nucleaire et Echographie, 37 - Tours (France); Rosset, P. [Centre Hospitalier Universitaire, Sce de Chirurgie Orthopedique et Traumatologique, 37 - Tours (France)

    2000-01-01

    The purpose of this study was to determine the indication of bone scintigraphy in hip prosthesis complications. Thirty-six patients and 38 hip prosthesis have had a {sup 99}Tc-MDP scintigraphy in our laboratory between 1995 and 1997. It concerns 32 cemented total prosthesis, 3 intermediate prosthesis and 3 non-cemented total prosthesis. For 14 prosthesis, complication (loosening or infection) was confirmed by surgical operation in 12 cases (4 isolated acetabular complications, 2 isolated femoral loosening, 3 global loosening and 3 infections) or by concordant data from different examinations in 2 cases (global loosening) where intervention was unrealizable. About other patients, absence of complication was confirmed by a favourable evolution lasting at least 12 months. A cetabular and femoral complications were detected by scintigraphy respectively with a sensitivity of 100 % and 90 %, a specificity of 85 % and 78 %, a PPV of 75 % and 60 % and NPV of 100 % and 96 %. High negative predictive value allows to eliminate a prosthesis complication in the case of a normal scintigraphy and to override decision when the clinic and the radiography are doubtful. Scintigraphy may recognize other bone fixation abnormalities which may be responsible of clinical symptomatology. (authors)

  7. Reducing surgical nurses' aseptic practice-related stress.

    Science.gov (United States)

    Aholaakko, Teija-Kaisa

    2011-12-01

    This paper aims to explore aseptic practice-related stress in surgery. The objectives are to define stress-related factors and the means to reduce the stress. Occupational stress is related to personal characteristics: job satisfaction and physiological and psychological well-being. The stress symptoms are often classified as part of a negative mood. Nurses have expressed stress when deadening their conscience to external demands with co-workers or internal working role-related demands. Surgery nurses expect fair division of work and compliance with rules. The hospital management, technology and the medical profession, instead of the needs of the patient, are recognised as a danger in the development of surgery nurses' role. A qualitative stimulated recall interview was performed in the surgery of the university hospital. Thirty-one operations were videotaped, and 31 nurses interviewed during videotape stimulation. The 1306 text pages were transcripted and analysed by a qualitative membership categorisation device analysis. The analysis revealed aseptic practice-related stress which constructed a sixteen level category. The membership categorisation identified connections between qualitatively attributed personnel and seven stress factors: working experience; time; equipment; person; patient; working morals and power. Final analysis revealed nurses reducing aseptic practice-related stress by safe, peaceful, competent and relative means. The aseptic practice-related stress varied from positive motivating feelings to exhaustion. The stress was experienced by medical and nursing co-workers and reduced by means which varied according to expertise and co-workers. This study showed needs for both the shared multiprofessional documentation of aseptic practice and better adherence to recommendations. Constructive means are useful when solving conflicts and replacing person-related aseptic practice with evidence-based. They may support nurses' professional growth, reduce

  8. Aseptic meningitis in children: analysis of 506 cases.

    Directory of Open Access Journals (Sweden)

    Athanasios G Michos

    Full Text Available BACKGROUND: Non-polio human enteroviruses are the leading cause of aseptic meningitis in children. The role of enterovirus PCR for diagnosis and management of aseptic meningitis has not been fully explored. METHODOLOGY/PRINCIPAL FINDINGS: A retrospective study was conducted to determine the epidemiological, clinical, and laboratory characteristics of aseptic meningitis and to evaluate the role of enterovirus PCR for the diagnosis and management of this clinical entity. The medical records of children who had as discharge diagnosis aseptic or viral meningitis were reviewed. A total of 506 children, median age 5 years, were identified. The annual incidence rate was estimated to be 17/100,000 children less than 14 years of age. Most of the cases occurred during summer (38% and autumn (24%. The dominant clinical symptoms were fever (98%, headache (94% and vomiting (67%. Neck stiffness was noted in 60%, and irritation in 46% of the patients. The median number of CSF cell count was 201/mm(3 with polymorphonuclear predominance (>50% in 58.3% of the cases. Enterovirus RNA was detected in CSF in 47 of 96 (48.9% children tested. Children with positive enterovirus PCR had shorter hospitalization stay as compared to children who had negative PCR or to children who were not tested (P = 0.01. There were no serious complications or deaths. CONCLUSIONS: Enteroviruses accounted for approximately one half of cases of aseptic meningitis. PCR may reduce the length of hospitalization and plays important role in the diagnosis and management of children with aseptic meningitis.

  9. The effect of cup outer sizes on the contact mechanics and cement fixation of cemented total hip replacements.

    Science.gov (United States)

    Hua, Xijin; Li, Junyan; Wang, Ling; Wilcox, Ruth; Fisher, John; Jin, Zhongmin

    2015-10-01

    One important loosening mechanism of the cemented total hip arthroplasty is the mechanical overload at the bone-cement interface and consequent failure of the cement fixation. Clinical studies have revealed that the outer diameter of the acetabular component is a key factor in influencing aseptic loosening of the hip arthroplasty. The aim of the present study was to investigate the influence of the cup outer diameter on the contact mechanics and cement fixation of a cemented total hip replacement (THR) with different wear penetration depths and under different cup inclination angles using finite element (FE) method. A three-dimensional FE model was developed based on a typical Charnley hip prosthesis. Two acetabular cup designs with outer diameters of 40 and 43 mm were modelled and the effect of cup outer diameter, penetration depth and cup inclination angle on the contact mechanics and cement fixation stresses in the cemented THR were studied. The results showed that for all penetration depths and cup inclination angles considered, the contact mechanics in terms of peak von Mises stress in the acetabular cup and peak contact pressure at the bearing surface for the two cup designs were similar (within 5%). However, the peak von Mises stress, the peak maximum principal stress and peak shear stress in the cement mantle at the bone-cement interface for the 43 mm diameter cup design were predicted to be lower compared to those for the 40 mm diameter cup design. The differences were predicted to be 15-19%, 15-22% and 18-20% respectively for different cup penetration depths and inclination angles, which compares to the clinical difference of aseptic loosening incidence of about 20% between the two cup designs. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  10. Implant retained auricular prosthesis with a modified hader bar: a case report.

    Science.gov (United States)

    Lovely, M; Dathan, Pradeep C; Gopal, Dinesh; George, Biji Thomas; Chandrasekharan Nair, K

    2014-06-01

    Auricular prostheses for defects of external ear are retained either by mechanical means or implants. All implant retained prostheses are retained by various means such as bar and clip, magnetic attachments or a combination of bar, clip and magnets. The commonest problem encountered with the bar and clip system is loosening of the clip after 3-4 months. When magnets are used as retaining component they tend to corrode over a period of time. So various alternative retention methods which possess good retentive qualities, ease of reparability and patient friendly were tried. In the present case a newly modified Hader bar design which can act as an additional retentive feature apart from the clip is employed to increase retention. The major advantages in the modified Hader bar system were that only two implants were employed, the additional loops in the Hader bar prevented micro movements and the retentive acrylic locks were easy to repair if broken. The modified Hader bar has anti-rotational slots which prevents the sliding or rotation of the prosthesis which gave new confidence to the patient who was otherwise worried of inadvertent displacement of the ear prosthesis while playing.

  11. COMPARISON OF CULTURE OF SYNOVIAL FLUID, PERIPROSTHETIC TISSUE AND PROSTHESIS SONICATE FOR THE DIAGNOSIS OF KNEE PROSTHESIS INFECTION

    Directory of Open Access Journals (Sweden)

    Andrej Trampuž

    2003-03-01

    Full Text Available Background. Synovial fluid and periprosthetic tissue specimens are the standard specimens cultured for the diagnosis of prosthetic joint infection (PJI. We hypothesize that ultrasonication of the explanted prosthesis may improve diagnosis of PJI by dislodging biofilm bacteria from the prosthesis surface and improve the sensitivity and specificity of diagnosis of PJI.Methods. Included were patients undergoing knee prosthesis exchange for septic or biomechanical failure and have not received antimicrobial therapy in the last 2 weeks prior specimen collection. Cultures of synovial fluid and periprosthetic tissue specimens were performed per the usual clinical practice. Additionally, explanted joint components were sonicated for 5 minutes at frequency 40 kHz in sterile Ringer’s solution; aliquots of 0.5 ml sonicate were plated onto five aerobic and five anaerobic blood agar plates, and incubated at 37 °C and examined for the next seven days. The number and identity of each colony morphology was recorded.Results. 35 patients undergoing knee replacement have been studied (24 for aseptic biomechanical failure and 11 for suspected PJI. In patients with PJI, coagulase-negative staphylococci (7 cases, Corynebacterium spp. (2 cases, Staphylococcus aureus (1 case, and viridans group streptococcus (1 case were recovered. Culture sensitivity and specificity were for synovial fluid 88% and 100%, for periprosthetic tissue 83% and 81%, and for explant sonicate 91% and 100%, respectively. In sonicate cultures higher numbers of microorganisms than in periprosthetic tissue cultures were consistently detected.Conclusions. Using synovial fluid, periprosthetic tissue, and explant sonicate cultures, 12%, 17% and 9% of PJI were missed, respectively. Explant sonicate cultures were the most sensitive with respect to the diagnosis of PJI, indicating that explant ultrasonication may improve bacterial recovery. In sonicate cultures, infecting organisms were detected in

  12. Sequential use of technetium 99m MDP and gallium 67 citrate imaging in the evaluation of painful total hip replacement

    International Nuclear Information System (INIS)

    Horoszowski, H.; Ganel, A.; Kamhin, M.; Zaltman, S.; Farine, I.

    1980-01-01

    Fourteen patients with 20 total hip joint replacements were studied for 14 painful prosthetic hips. Clinical examination, plain film radiographs and 99 Tcsup(m)-methylene diphosphonate bone scans failed to differentiate between infection and mechanical loosening of a prosthesis. Sequential use of 99 Tcsup(m)-methylene diphosphonate and 67 Ga-citrate bone scans were performed in an attempt to discover underlying infectious process. Increased focal uptake of both radiopharmaceuticals over the same hip indicated an infectious process responsible for prosthetic loosening. There were no false positive gallium examinations. Sequential use of 99 Tcsup(m)-phosphate compounds and 67 Ga-citrate is recommended for differentiation between mechanical loosening of a prosthesis and loosening of a prosthesis secondary to an infectious process. (U.K.)

  13. Radiography, radionuclide imaging, and asthrography in the evaluation of total hip and knee replacement. [/sup 99m/Tc-phosphate

    Energy Technology Data Exchange (ETDEWEB)

    Gelman, M.I.; Coleman, R.E.; Stevens, P.M.; Davey, B.W.

    1978-09-01

    Twenty patients with 21 total joint replacements including 17 hips and 4 knees were studied by plain film radiography, radionuclide imaging, and subtraction arthrography to evaluate these procedures for assessing prosthetic complications. Surgery was performed in 14 patients and confirmed loosening of 8 femoral and 7 acetabular hip prosthesis components and 1 femoral and 4 tibial knee prosthesis components. Plain films suggested loosening of only 9 hip components and no knee components. In contrast, radionuclide imaging and subtraction arthrography were considerably more effective in demonstrating loosening as well as other causes of the painful total joint prosthesis.

  14. Radiography, radionuclide imaging, and asthrography in the evaluation of total hip and knee replacement

    International Nuclear Information System (INIS)

    Gelman, M.I.; Coleman, R.E.; Stevens, P.M.; Davey, B.W.

    1978-01-01

    Twenty patients with 21 total joint replacements including 17 hips and 4 knees were studied by plain film radiography, radionuclide imaging, and subtraction arthrography to evaluate these procedures for assessing prosthetic complications. Surgery was performed in 14 patients and confirmed loosening of 8 femoral and 7 acetabular hip prosthesis components and 1 femoral and 4 tibial knee prosthesis components. Plain films suggested loosening of only 9 hip components and no knee components. In contrast, radionuclide imaging and subtraction arthrography were considerably more effective in demonstrating loosening as well as other causes of the painful total joint prosthesis

  15. Giant Leaking Colloid Cyst Presenting with Aseptic Meningitis

    DEFF Research Database (Denmark)

    Bakhtevari, Mehrdad Hosseinzadeh; Sharifi, Guive; Jabbari, Reza

    2015-01-01

    BACKGROUND: Colloid cysts are benign third ventricle lesions that need to be diagnosed correctly because of their association with sudden death. Chemical or aseptic meningitis is a rare presentation of a colloid cyst. METHODS: We present a case of a 69-year-old man with fever, alteration of mental...... status, and meningismus. Microbiological examination of the cerebrospinal fluid revealed aseptic meningitis. Brain imaging revealed a third ventricular colloid cyst with hydrocephalus. RESULTS: The tumor was resected via endoscopic intervention. There were no persistent operative complications related...... to the endoscopic procedure. CONCLUSIONS: Chemical or aseptic meningitis is an unusual clinical manifestation of a colloid cyst, complicating the differential diagnosis, especially in the elderly....

  16. Amoxicillin-induced aseptic meningoencephalitis

    Directory of Open Access Journals (Sweden)

    Radi Shahien

    2010-06-01

    Full Text Available Radi Shahien1, Vetaly Vieksler1, Abdalla Bowirrat11Department of Neurology and Neurophysiology, Ziv Medical Center, Safed, IsraelAbstract: Meningitis is usually produced by an infectious agent, but there are multiple noninfectious causes. Drug-induced aseptic meningitis (DIAM is an important entity and has been reported as an uncommon adverse reaction with numerous agents. Thus, DIAM constitutes a diagnostic and patient management challenge. We present a patient with three episodes of aseptic meningitis due to amoxicillin, and then review the literature on this rare idiosyncratic event which may occur after local or systemic drug administration. A 77-year-old man was admitted to our hospital with fever, headache, and neck stiffness. Seven days before admission he had a dental and gingival inflammation. He was treated with two oral doses of 500 mg daily of amoxicillin for one week. The seventh day he awoke with the complaints that prompted hospital admittance. Amoxicillin was stopped 1 day before his admission. From his history we knew of two similar episodes: The first episode was after a dental procedure 3 months before this incident. He had received a 1-week course of postprocedure amoxicillin of 500 mg daily and had similar headache, fever, and chills during the entire course of treatment. He wasn’t admitted to the hospital, because he stopped taking amoxicillin and he felt spontaneous pain relief after taking symptomatic pain treatment. The second episodes was 6 months after his first admission, he had been admitted to our hospital with the same symptoms. Amoxicillin was stopped and changed with intravenous (IV ceftriaxone (CTRX for 10 days due to suspected partial untreated meningitis. The patient improved rapidly within 2 days and was discharged from the hospital. On the basis of these three confirmed episodes of meningitis after recurrent exposure to amoxicillin, with repetitive negative testing for viral, bacterial, and mycobacterial

  17. Radiation sterilization of plastic packing materials and aseptic packaging

    International Nuclear Information System (INIS)

    Tokuoka, Keiko

    1986-01-01

    In the present day of 'satiation', quality, not quantity, is emphasized for foods, the consumers being oriented toward raw and healthy foodstuff. Aseptic Packaging is excellent means of conservation. While conventionally chemicals have been used for sterilization of packing materials for aseptic packaging, the sterilization by radiation is used in part recently. The following are described : history of aseptic packaging and its features, sterilization by radiation, γ-ray sterilization of large-sized containers, the development of an aseptic packaging system using electron rays, the occurrence of offensive odors from packing materials (comparison of odors from various materials, volatile substances occurring in irradiated polyethylene, influence of film grade upon the formation of carboxylic acid, influence of the irradiation conditions upon the occurrences of volatile substances, volatile substances occurring in the irradiation of bag-in-box packing materials), changes in properties of the packing materials. (Mori, K.)

  18. Severe aseptic meningitis with hydrocephalus following iotrolan myelography: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Hyoung; Ha, Choong Kun; Ahn, In Oak [Gyeongsang National University College of Medicine, Jinju (Korea, Republic of)

    1993-05-15

    A case of severe aseptic meningitis with communicating hydrocephalus following iotrolan myelography is presented. The patient's condition improved very quickly after corticosteroid therapy. Rapid improvement and absence of pathogenic organisms in the CSF culture strongly favor an aseptic meningitis. This is the first reported case of aseptic meningitis with the secondary development of hydrocephalus caused by iotrolan myelography.

  19. Severe aseptic meningitis with hydrocephalus following iotrolan myelography: A case report

    International Nuclear Information System (INIS)

    Kim, Jae Hyoung; Ha, Choong Kun; Ahn, In Oak

    1993-01-01

    A case of severe aseptic meningitis with communicating hydrocephalus following iotrolan myelography is presented. The patient's condition improved very quickly after corticosteroid therapy. Rapid improvement and absence of pathogenic organisms in the CSF culture strongly favor an aseptic meningitis. This is the first reported case of aseptic meningitis with the secondary development of hydrocephalus caused by iotrolan myelography

  20. [Tripolar arthroplasty for recurrent total hip prosthesis dislocation].

    Science.gov (United States)

    Beaulé, P-E; Roussignol, X; Schmalzried, T-P; Udomkiat, P; Amstutz, H-C; Dujardin, F-H

    2003-05-01

    revision procedure was necessary for one patient during the 4(th) year because of a fracture of the polyethylene insert on a metal-back cup; the insert alone was changed. Excepting the patient with infection, there were no cases of certain or probable loosening during the follow-up. The tripolar prosthesis with a mobile cup and a large-diameter head appears to be a reliable solution for these severely unstable hips. The procedure can often be limited to the acetabular component, reducing morbidity. The thickness of the polyethylene cup is a limitation which may affect long-term survival. Search for a highly wear-resistant couple continues.

  1. Drug induced aseptic meningitis

    African Journals Online (AJOL)

    PROF. EZECHUKWU

    2013-09-29

    Sep 29, 2013 ... Abstract. Drug-induced aseptic meningitis (DIAM) is a rare but important and often challenging diagnosis for the physician. Intake of antimicrobials, steroids, anal- gesics amongst others has been implicated. Signs and symptoms generally develop within 24-48 hours of drug ingestion. The pa- tient often ...

  2. Aseptic techniques(practical guide no.3); Practico no.3-Tecnicas asepticas

    Energy Technology Data Exchange (ETDEWEB)

    Nappa, Andres; Souto Pais, Beatriz [Centro de Investigaciones Nucleares, Montevideo (Uruguay)

    1994-12-31

    Definition of aseptic techniques in relation with the labor of Radiopharmacy.Control of environment and working areas.Control of materials entered into an aseptic area: water, nitrogen,vials,stoppers,needles and syringes. Personnel and manipulations control,choosing of materials,precautions in the aseptic manipulation and sterility preservation during usage life. Bacteriological membrane filtration in sterilized conditions. Work in a laminar flow unit. Protocol of Practical task 3. Bibliography

  3. Total hip arthroplasty in Jesenice General hospital 1985–2006 – what has been done and look forward

    Directory of Open Access Journals (Sweden)

    Tomaž Silvester

    2007-11-01

    Full Text Available Background: Total arthroplasty is one of the most interesting and fast developing fields in orthopaedic surgery. Practically every joint in the human body is involved, total hip arthroplasties (THA being most frequent and with the longest history. Information on long-term results and survival of different types of prosthesis is invaluable for both patients and surgeons.Patients and methods: Between 1985 and 2006 there were 1563 THAs performed in Jesenice General Hospital. Average age at the time of operation was 67 years, almost two thirds of patients were women. The reason for operation was in 72 % idiopathic arthrosis and in 14 % sequaele of dysplasia.Results: There were 1370 primary procedures and 193 revisions (12.6 %. Aseptic loosening of the implant was the most frequent reason for revision (74 % and infection was observed in 1.5 %. In the first ten years of this research hybrid type of prosthesis was most frequently used, but nowadays, non-cemented prosthesis is used in majority of cases.Conclusions: Total hip arthroplasty is well established procedure at the Jesenice General Hospital. It considerably improves quality of life of the patient, for both, short- and long term, results are very good. New minimal invasive surgical techniques make postoperative rehabilitation faster and easier. The Register of prosthesis enables us to regularly analyze the results and provides treatment outcome information concerning the choice of prosthesis and the optimal surgical technique. Jesenice General Hospital is well recognized as one of the centers for arthroplasties in our country.

  4. Microbial Load in Septic and Aseptic Procedure Rooms.

    Science.gov (United States)

    Harnoss, Julian-Camill; Assadian, Ojan; Diener, Markus Karl; Müller, Thomas; Baguhl, Romy; Dettenkofer, Markus; Scheerer, Lukas; Kohlmann, Thomas; Heidecke, Claus-Dieter; Gessner, Stephan; Büchler, Markus Wolfgang; Kramer, Axel

    2017-07-10

    Highly effective measures to prevent surgical wound infections have been established over the last two decades. We studied whether the strict separation of septic and aseptic procedure rooms is still necessary. In an exploratory, prospective observational study, the microbial concentration in an operating room without a room ventilating system (RVS) was analyzed during 16 septic and 14 aseptic operations with the aid of an air sampler (50 cm and 1 m from the operative field) and sedimentation plates (1 m from the operative field, and contact culture on the walls). The means and standard deviations of the microbial loads were compared with the aid of GEE models (generalized estimation equations). In the comparison of septic and aseptic operations, no relevant differences were found with respect to the overall microbial concentration in the room air (401.7 ± 176.3 versus 388.2 ± 178.3 CFU/m 3 ; p = 0.692 [CFU, colony-forming units]) or sedimentation 1 m from the operative field (45.3 ± 22.0 versus 48.7 ± 18.5 CFU/m 2 /min; p = 0.603) and on the walls (35.7 ± 43.7 versus 29.0 ± 49.4 CFU/m 2 /min; p = 0.685). The only relevant differences between the microbial spectra associated with the two types of procedure were a small amount of sedimentation of Escherichia coli and Enterococcus faecalis in septic operations, and of staphylococcus aureus and pseudomonas stutzeri in aseptic operations, up to 30 minutes after the end of the procedure. These data do not suggest that septic and aseptic procedure rooms need to be separated. In interpreting the findings, one should recall that the study was not planned as an equivalence or non-inferiority study. Wherever patient safety is concerned, high-level safety concepts should only be demoted to lower levels if new and convincing evidence becomes available.

  5. Loosening Psychometric Constraints on Educational Assessments

    Science.gov (United States)

    Kane, Michael T.

    2017-01-01

    In response to an argument by Baird, Andrich, Hopfenbeck and Stobart (2017), Michael Kane states that there needs to be a better fit between educational assessment and learning theory. In line with this goal, Kane will examine how psychometric constraints might be loosened by relaxing some psychometric "rules" in some assessment…

  6. Mid term results of Furlong LOL uncemented hip hemiarthroplasty for fractures of the femoral neck.

    Science.gov (United States)

    Chandran, Prakash; Azzabi, Mohammed; Burton, Dave J C; Andrews, Mark; Bradley, John G

    2006-08-01

    We report the mid-term results of hemiarthroplasty with the Furlong hydroxyapatite coated bipolar prosthesis for displaced (Garden type III and IV) intracapsular hip fracture in 480 patients operated between 1989 and 2000. Three hundred sixty eight (77%) patients were lost to follow-up due to death, dementia or movement away from the area. In the patients followed up there was an 8% reoperation rate for infection, aseptic loosening, periprosthetic fracture and acetabular erosion. One hundred and twelve patients with a mean follow-up of 4 years (3-14) were studied. Eighty eight percent had no or slight pain, 77% could mobilise outdoors and 89% needed either no aid or a single walking stick to mobilise. Radiographic assessment revealed a stable implant with visible osseointegration in 91%. We conclude that hemiarthroplasty with the hydroxyapatite coated bipolar Furlong LOL prosthesis for displaced intracapsular fracture of the neck of the femur gives good mid term results in elderly patients for return to mobility, use of mobility aids and freedom from pain. It avoids the need for cement and provides satisfactory incorporation into the host bone. The use of a modular head makes revision to total hip replacement easier.

  7. Analysis of hip perfusion at early and reversible stages of aseptic hip necrosis

    International Nuclear Information System (INIS)

    Predic, P.; Dodig, D.; Karner, I.

    2002-01-01

    Aim: A proper early diagnosis of aseptic hip necrosis is very important for further therapy.Since there has always been a question of the amount of perfusion in hips at different stages of aseptic hip necrosis we tried to impartially examine the perfusion in hips at early and reversible stages of aseptic hip necrosis. Material and Methods:Study included 143 patients with aseptic hip necrosis.The 550-740 MBq of Tc-99m-DPD were on bolus injected.All patients were subjected to 3-phase scintigraphy of hips and quantitative calculation of relative perfusion in the artery phase (3T) at early and repeated at reversible stages of aseptic hip necrosis. Results: At the early stage of aseptic hip necrosis the obtained 3T was decreased from 0.94-0.69 (3T=0.80).Scintigrams showed a moderate increase or diffuse accumulation. At the reversible stages we obtained 3T decreased from 0.92-0.71 (3T=0.79) thus evidencing hypoperfusion.Scintigrams showed an diffuse increased accumulation. Conclusion: With the aseptic hip necrosis quantitative analysis of perfusion in the artery phase-3T indicates that the perfusion is decreased at all stages of the process which however shows a significantly falling trend with the progress of the disease

  8. Early postoperative dislocation of the anterior Maverick lumbar disc prosthesis: report of 2 cases.

    Science.gov (United States)

    Gragnaniello, Cristian; Seex, Kevin A; Eisermann, Lukas G; Claydon, Matthew H; Malham, Gregory M

    2013-08-01

    fault: Both plates of the dislocated implants looked normal and manufacturer analysis reported no fault; 4) patient factors: Both dislocations happened early in the postoperative period, after hyperextension of the spine while the patient was supine in bed. Bracing would not have reduced hyperextension. Dislocation of a lumbar spinal implant represents a life-threatening complication and should therefore be considered and recognized early. Radiographic and CT studies of both the lumbar spine (for prosthesis) and the abdomen (for hematoma) should be performed, as should CT angiography (for vessel damage or occlusion). Any anterior lumbar revision surgery is hazardous, and it is strongly advisable to have a vascular surgeon scrubbed. In cases of dislocation or extrusion of a lumbar interbody prosthesis, the salvage revision strategy is fusing the segment via the same anterior approach. Surgeons should be aware of the risk of anterior dislocation of the Maverick prosthesis. Keel cutters should be regularly checked for sharpness, as they may be implicated in the loosening of implants. Patients and their physical therapists should also avoid lumbar hyperextension in the early postoperative period.

  9. Bolt-loosening identification of bolt connections by vision image-based technique

    Science.gov (United States)

    Nguyen, Tuan-Cuong; Huynh, Thanh-Canh; Ryu, Joo-Young; Park, Jae-Hyung; Kim, Jeong-Tae

    2016-04-01

    In this study, an algorithm using image processing techniques is proposed to identify bolt-loosening in bolted connections of steel structures. Its basic concept is to identify rotation angles of nuts from a pictured image, and is mainly consisted of the following 3 steps: (1) taking a picture for a bolt joint, (2) segmenting the images for each nut by image processing techniques, and (3) identifying rotation angle of each nut and detecting bolt-loosening. By using the concept, an algorithm is designed for continuous monitoring and inspection of the bolt connections. As a key imageprocessing technique, Hough transform is used to identify rotation angles of nuts, and then bolt-loosening is detected by comparing the angles before and after bolt-loosening. Then the applicability of the proposed algorithm is evaluated by experimental tests for two lab-scaled models. A bolted joint model which consists of a splice plate and 8 sets of bolts and nuts with 2×4 array is used to simulate inspection of bridge connections, and a model which is consisted of a ring flange and 32 sets of bolt and nut is used to simulate continuous monitoring of bolted connections in wind turbine towers.

  10. CT scan of bacterial and aseptic meningitis

    International Nuclear Information System (INIS)

    Takemoto, Kazumasa; Saiwai, Shigeo; Tamaoka, Koichi

    1983-01-01

    CT scans of the patients with aseptic and bacterial meningitis were reviewed and compared to previous reports. In aseptic meningitis, no abnormal CT findings were observed. In bacterial meningitis, CT findings were ventricular dilatation, subdural fluid collection, parenchymal low density, intracerebral hematoma and meningeal enhancement after contrast injection. Three patients among 48 suffered from status epileptics during the course of the illness. All of 3 patients developed parenchymal inhomogeneous low density and progressive ventricular dilatation which did not improve after ventricular peritoneal shunt surgery. We believe that these changes are most likely due to hypoxic hypoxemia during epileptic seizure and meningitis itself seems to play a little role. (author)

  11. Paediatric Investigators Collaborative Network on Infections in Canada (PICNIC study of aseptic meningitis

    Directory of Open Access Journals (Sweden)

    Robinson Joan L

    2006-04-01

    Full Text Available Abstract Background The seasonality, clinical and radiographic features and outcome of aseptic meningitis have been described for regional outbreaks but data from a wider geographic area is necessary to delineate the epidemiology of this condition. Methods A retrospective chart review was completed of children presenting with aseptic meningitis to eight Canadian pediatric hospitals over a two-year period. Results There were 233 cases of proven enteroviral (EV meningitis, 495 cases of clinical aseptic meningitis and 74 cases of possible aseptic meningitis with most cases occurring July to October. Headache, vomiting, meningismus and photophobia were more common in children ≥ 5 years of age, while rash, diarrhea and cough were more common in children Conclusion The clinical presentation of aseptic meningitis varies with the age of the child. Absence of CSF pleocytosis is common in infants

  12. Outcome in design-specific comparisons between highly crosslinked and conventional polyethylene in total hip arthroplasty

    DEFF Research Database (Denmark)

    Johanson, Per-Erik; Furnes, Ove; Ivar Havelin, Leif

    2017-01-01

    assessed risk of revision for any reason and for aseptic loosening using Cox regression adjusted for age, sex, femoral head material and size, surgical approach, stem fixation, and presence of hydroxyapatite coating (uncemented cups). Results - The CPE version of the ZCA cup had a risk of revision for any...... for any reason and revision due to aseptic loosening and/or osteolysis. Patients and methods - Using the Nordic Arthroplasty Register Association (NARA) database, we identified cup and liner designs where either XLPE or CPE had been used in more than 500 THAs performed for primary hip osteoarthritis. We...

  13. [Aseptic cutaneous breast abscesses associated with ulcerative colitis].

    Science.gov (United States)

    Sallé de Chou, C; Ortonne, N; Hivelin, M; Wolkenstein, P; Chosidow, O; Valeyrie-Allanore, L

    2016-02-01

    Inflammatory bowel diseases are associated with a broad range of cutaneous lesions. Herein we report the first case of aseptic skin abscesses associated with ulcerative colitis. Since March 2008, a 40-year-old woman presented with bilateral mammary abscesses, relapsing despite repeated antibiotic treatment. She was followed for ulcerative colitis diagnosed in 2011 by means of a rectal biopsy. Despite four surgical procedures, there was no improvement in her mammary abscesses and bilateral mastectomy was then proposed because of the persistent symptoms. Her general state of health remained stable. Clinically, there were bilateral inflammatory nodes with fistulae and pus. These lesions were extremely painful. Mild inflammatory syndrome was noted, but the immunological tests revealed nothing of note. Bacteriological, parasitological and mycological tests on biopsy specimens were negative. Histological examination of a surgical biopsy revealed lymphoplasmacytic infiltration of the dermis and subcutis with altered polymorphonuclear cells and epithelioid granuloma. The CT-scan showed no other remote lesions. The final diagnosis was cutaneous aseptic abscess syndrome associated with ulcerative colitis. Colchicine 1mg/day was initiated and resulted in regression of the skin lesions, with complete remission at one year of follow-up. Aseptic abscess syndrome must be considered in the event of recurrent aseptic cutaneous abscesses which may be associated with inflammatory bowel disease. Surgery should be avoided and treatment should be based on suitable drug therapy. Copyright © 2016. Published by Elsevier Masson SAS.

  14. The changing epidemiology of pediatric aseptic meningitis in Daejeon, Korea from 1987 to 2003

    Directory of Open Access Journals (Sweden)

    Lee Mi-Hee

    2005-11-01

    Full Text Available Abstract Background Aseptic meningitis is a relatively frequent childhood disease and virologic data suggest that enteroviruses are the commonest etiologic agents. We evaluated the epidemiologic characteristics of aseptic meningitis in Daejeon, South Korea from 1987 to 2003. Methods 2201 medical records of children with aseptic meningitis admitted to The Catholic University of Korea, Daejeon St Mary's Hospital were retrospectively analyzed. Results Outbreaks of aseptic meningitis were observed in 1990, 1993, 1996, 1997, 2001 and 2002. The age distribution of cases was relatively uniform, with a higher incidence in those aged P = 0.001. Neurologic sequelae were observed in 0.7% of the patients. Conclusion Aseptic meningitis, rare before the 1980s in Korea, has since become a common clinical entity. Since 1990, outbreaks of aseptic meningitis have occurred every 1 to 3 years in Daejeon in keeping with Korea-wide epidemics. The frequency of disease affecting children less than one year of age may reflect herd immunity to the epidemic strain.

  15. [Mid-term effectiveness of total hip arthroplasty with collum femoris preserving prosthesis].

    Science.gov (United States)

    Li, Mingqing; Hu, Yihe; Li, Kanghua; Liao, Qiande; Wen, Ting; Zhong, Da

    2012-08-01

    To discuss the clinical application of total hip arthroplasty (THA) with collum femoris preserving (CFP) prosthesis and to analyze the mid-term effectiveness. Between January 2004 and February 2007, 45 patients (48 hips) underwent THA with CFP prosthesis. There were 29 males (31 hips) and 16 females (17 hips) with an average age of 48.8 years (range, 38-60 years), including 20 left hips, 22 right hips, and 3 bilateral hips. The causes of hip replacement were osteoarthritis (20 cases), avascular necrosis of femoral head (13 cases), dysplasia (4 cases), rheumatoid arthritis (3 cases), posttraumatic osteoarthritis (2 cases), ankylosing spondylitis (2 cases), and Perths disease (1 case). The average disease duration was 6.1 years (range, 2-13 years). Harris scores, visual analogue scale (VAS) score, and the hip range of motion (ROM) were recorded at pre- and post-operation. The X-ray films were taken at pre- and post-operation to observe the position, loosening of the prosthesis, and ectopic ossification. The gait of patients were also evaluated during follow-up. Short-form 36 health survey scale (SF-36) was used to evaluate the life quality of patients. All 45 patients were followed up 5-8 years with an average of 6.4 years. All the incisions healed by first intention. No infection, hip dislocation, nerve injury, or deep vein thrombosis occurred. Six cleavage fractures (13.3%) of the lateral femoral diaphysis at the distal prosthesis occurred during operation, which healed at 8 months postoperatively without any treatment. Mild ectopic ossification occurred in 4 patients (8.9%) who had no discomfort. Five patients (11.1%) had bone mineral density loss in the region of the proximal femur. The survival rates of the cups and stems were all 100% at last follow-up. The results of Harris score, VAS score, and ROM of the hip joint at 1 year postoperatively and last follow-up were significantly better than preoperative ones (P 0.05) except the Harris score (P fair in 6 hips

  16. Aseptic Plant Culture System (APCS), Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Aseptic plant culture plays a significant role in biotechnology and plant physiology research, and in vegetative propagation of many plant species. The development...

  17. Bioactive Coatings for Orthopaedic Implants—Recent Trends in Development of Implant Coatings

    Directory of Open Access Journals (Sweden)

    Bill G. X. Zhang

    2014-07-01

    Full Text Available Joint replacement is a major orthopaedic procedure used to treat joint osteoarthritis. Aseptic loosening and infection are the two most significant causes of prosthetic implant failure. The ideal implant should be able to promote osteointegration, deter bacterial adhesion and minimize prosthetic infection. Recent developments in material science and cell biology have seen the development of new orthopaedic implant coatings to address these issues. Coatings consisting of bioceramics, extracellular matrix proteins, biological peptides or growth factors impart bioactivity and biocompatibility to the metallic surface of conventional orthopaedic prosthesis that promote bone ingrowth and differentiation of stem cells into osteoblasts leading to enhanced osteointegration of the implant. Furthermore, coatings such as silver, nitric oxide, antibiotics, antiseptics and antimicrobial peptides with anti-microbial properties have also been developed, which show promise in reducing bacterial adhesion and prosthetic infections. This review summarizes some of the recent developments in coatings for orthopaedic implants.

  18. MR features in patients with residual paralysis following aseptic meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Dae Chul; Park, Young Seo [College of Medicine, Asan Meidcal Center, University of Ulsan, Seoul (Korea, Republic of)

    1991-01-15

    MR studies were performed in three patients with paralysis in the lower extremities. Poliomyelitis-like paralysis can be caused by neurovirulent strains of nonpolioenteroviruses. Entervirus 71 (EV 71) is documented as one of the potentially neurovirulent strains and a causative agent of some epidemics (1-7). The clinical manifestations associated with the EV 71 infection include aseptic meningitis, hand-food-mouth disease (HFMD), acute respiratory illness and gastrointestinal disease(6). Although rarely fatal, flaccidparalysis can be followed by EV 71 induced aseptic meningitis. Anterior horn cell necrosis was suggested on MR in two patients with residual paralysis (7). MR features, however, have not yet been described in detail. In this report we present three cases of patients with clinical evidence of EV 71 induced aseptic meningitis whose MR studies showed residual changes in spinal cord.

  19. MR features in patients with residual paralysis following aseptic meningitis

    International Nuclear Information System (INIS)

    Suh, Dae Chul; Park, Young Seo

    1991-01-01

    MR studies were performed in three patients with paralysis in the lower extremities. Poliomyelitis-like paralysis can be caused by neurovirulent strains of nonpolioenteroviruses. Entervirus 71 (EV 71) is documented as one of the potentially neurovirulent strains and a causative agent of some epidemics (1-7). The clinical manifestations associated with the EV 71 infection include aseptic meningitis, hand-food-mouth disease (HFMD), acute respiratory illness and gastrointestinal disease(6). Although rarely fatal, flaccidparalysis can be followed by EV 71 induced aseptic meningitis. Anterior horn cell necrosis was suggested on MR in two patients with residual paralysis (7). MR features, however, have not yet been described in detail. In this report we present three cases of patients with clinical evidence of EV 71 induced aseptic meningitis whose MR studies showed residual changes in spinal cord

  20. An outbreak of aseptic meningitis in Podlaskie Voivodeship in 2014

    Directory of Open Access Journals (Sweden)

    Magda Orzechowska

    2016-12-01

    Full Text Available Enteroviruses cause common infections with various clinical course and forms, such as hand-foot-and-mouth disease (Boston exanthem disease, herpangina, myocarditis and pericarditis, widespread myositis (epidemic pleurodynia, Bornholm disease, or aseptic inflammation of the nervous system, among children and adolescents. An increase in aseptic meningitis cases of enteroviral aetiology, including the E30 virus, was occasionally observed in various European countries. In 2014, an outbreak of aseptic meningitis was reported in Podlaskie Voivodeship. A total of 640 cases were reported between June 1 and November 30, 2014, of which 228 had confirmed enteroviral aetiology. Summer and autumn seasons favour the incidence of viral infections of the central nervous system. Symptomatic infections are more common in males than females. Infections with enterovirus show the tendency to form endemic regions.

  1. Aseptic Plant Culture System (APCS), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Aseptic plant culture plays a significant role in biotechnology and plant physiology research and in vegetative propagation of many plant species. The development of...

  2. Cat scratch disease complicated with aseptic meningitis and neuroretinitis

    Directory of Open Access Journals (Sweden)

    Vitor Laerte Pinto Jr.

    Full Text Available Cat scratch disease (CSD is a self limited condition characterized by fever, lymph node enlargement and less often eye involvement. Central nervous system involvement by Bartonella henselae infection is possibly an important cause of morbidity; its role as an agent of aseptic meningitis is unknown. We report a case of a 40 years-old man with CSD accompanied by aseptic meningitis and neuroretinitis. Serum indirect immmunofluorescence (IFI assays for B. henselae were positive and the cerebrospinal fluid (CSF analysis showed mononuclear pleocytosis and increased level of protein. Serological tests for other etiologies were negative. The patient responded well to antibiotic therapy with oral doxycicline plus rifampin and in the 12th day of hospitalization evolved to total regression of the headache and partial regression of the visual loss. Clinicians should consider CSD as a differential diagnosis when assessing previously healthy patients with aseptic meningitis associated with regional lymphadenopathy and epidemiological history of feline contact.

  3. Magnetic thermometry in the aseptic processing of foods containing particulates (abstract)

    Science.gov (United States)

    Ghiron, Kenneth; Litchfield, Bruce

    1997-04-01

    Aseptic processing of foods has many advantages over canning, including higher efficiency, lighter packaging, better taste, and higher nutritional value. Aseptic processing is different from canning where the food and container are sterilized together. Instead, a thin stream of food is heated and the packaging is independently sterilized before the food is placed in the package. However, no aseptic processes have been successfully filed with the FDA for foods containing sizable solid particles because of uncertainties in the thermal sterilization of the particles (e.g., soup). We have demonstrated that by inserting small paramagnetic particles in the interior of the simulated and real food particles, the local temperature can be measured. With this information, any questions about the adequate sterilization of the particles can be resolved. The measurements were done by directing the food stream through a magnetic field and sensing the voltages induced in a pickup coil by the motion of the magnetized particles. Details of the equipment design and data analysis will be discussed along with an introduction to the aseptic processing of foods.

  4. [Endoprosthesis of the ankle joint. Indications and long-term results].

    Science.gov (United States)

    Endrich, B; Terbrüggen, D

    1991-10-01

    The treatment of a post-traumatic, progressively more painful ankle joint causes increasing disablement. It might require alternatives to conventional surgery if a patient does not consent to ankle arthrodesis to alleviate the pain. Therefore, we report on a retrospective study of 10 patients (age 25-73 years at the time of surgery). All of them refused arthrodesis; thus 10 total ankle arthroplasties were performed between 1982 and 1989. 5 women and 5 men were treated who have been suffering from severe post-traumatic arthrosis for 3-46 years. Since performance of a single-axis arthroplasty (ICLH prosthesis) in each patient, the mean follow-up has been 4.6 years. One year after surgery, the results could be considered good or excellent in 9 of the 10 patients; only 1 person experienced local wound infection, which led to removal of the implant 4 months later and ultimately to arthrodesis. Two years later, 7 patients are eligible for follow-up because 1 underwent surgery in February 1989. Another patient experienced aseptic loosening after 18 months; he was admitted to our hospital for arthrodesis. Three years after endoprosthetic surgery, all except 1 woman with occasional pain and stiffness were found to have satisfactory results on follow-up. The relief of pain was gratifying in all patients, with ankle function well maintained (at least 0-0-30 degrees). At present, the prosthesis is still functional in 6 patients (surgery 1.5-8 years ago). They can go about their usual daily business without apparent pain and with appropriate function; 2 of them, however, show radiolucent lines on standard X-rays of the ankle, suggesting some loosening.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Pedicle screw loosening is correlated to chronic subclinical deep implant infection: a retrospective database analysis.

    Science.gov (United States)

    Leitner, Lukas; Malaj, Isabella; Sadoghi, Patrick; Amerstorfer, Florian; Glehr, Mathias; Vander, Klaus; Leithner, Andreas; Radl, Roman

    2018-04-13

    Spinal fusion is used for treatment of spinal deformities, degeneration, infection, malignancy, and trauma. Reduction of motion enables osseous fusion and permanent stabilization of segments, compromised by loosening of the pedicle screws (PS). Deep implant infection, biomechanical, and chemical mechanisms are suspected reasons for loosening of PS. Study objective was to investigate the frequency and impact of deep implant infection on PS loosening. Intraoperative infection screening from wound and explanted material sonication was performed during revision surgeries following dorsal stabilization. Case history events and factors, which might promote implant infections, were included in this retrospective survey. 110 cases of spinal metal explantation were included. In 29.1% of revision cases, infection screening identified a germ, most commonly Staphylococcus (53.1%) and Propionibacterium (40.6%) genus. Patients screened positive had a significant higher number of previous spinal operations and radiologic loosening of screws. Patients revised for adjacent segment failure had a significantly lower rate of positive infection screening than patients revised for directly implant associated reasons. Removal of implants that revealed positive screening effected significant pain relief. Chronic implant infection seems to play a role in PS loosening and ongoing pain, causing revision surgery after spinal fusion. Screw loosening and multiple prior spinal operations should be suspicious for implant infection after spinal fusion when it comes to revision surgery. These slides can be retrieved under Electronic Supplementary Material.

  6. Robotic lower limb prosthesis design through simultaneous computer optimizations of human and prosthesis costs

    Science.gov (United States)

    Handford, Matthew L.; Srinivasan, Manoj

    2016-02-01

    Robotic lower limb prostheses can improve the quality of life for amputees. Development of such devices, currently dominated by long prototyping periods, could be sped up by predictive simulations. In contrast to some amputee simulations which track experimentally determined non-amputee walking kinematics, here, we explicitly model the human-prosthesis interaction to produce a prediction of the user’s walking kinematics. We obtain simulations of an amputee using an ankle-foot prosthesis by simultaneously optimizing human movements and prosthesis actuation, minimizing a weighted sum of human metabolic and prosthesis costs. The resulting Pareto optimal solutions predict that increasing prosthesis energy cost, decreasing prosthesis mass, and allowing asymmetric gaits all decrease human metabolic rate for a given speed and alter human kinematics. The metabolic rates increase monotonically with speed. Remarkably, by performing an analogous optimization for a non-amputee human, we predict that an amputee walking with an appropriately optimized robotic prosthesis can have a lower metabolic cost - even lower than assuming that the non-amputee’s ankle torques are cost-free.

  7. Mechanical compression of a fibrous membrane surrounding bone causes bone resorption

    NARCIS (Netherlands)

    van der Vis, H. M.; Aspenberg, P.; Tigchelaar, W.; van Noorden, C. J.

    1999-01-01

    Early micromovement and migration of a prosthesis of a hip or knee predicts late clinical loosening of the prosthesis. Such migration is likely to be associated with mechanical compression of the fibrous membrane interpositioned between bone and prosthesis during movement. Compression of the fibrous

  8. Flexible walled container having membrane fitment for use with aseptic filling apparatus

    International Nuclear Information System (INIS)

    Davis, J.C.; Reiss, R.J.; Rica, A.F.

    1984-01-01

    There is disclosed an aseptic flexible walled container having a rigid fitment member cooperative with an aseptic filling apparatus and including a neck, outer flanges surrounding the neck, a frangible membrane and an outer end rim receptive of an hermetically sealed lid. The neck is formed with an internal chamferred seating shoulder for fluid-tight engagement with a fill tube. One outer flange cooperates with clamping jaws of the aseptic filling apparatus for detachably sealing the fitment to a sterilizing chamber and placing it in position for insertion of the filling tube which ruptures the membrane and permits the aseptic introduction of product to the container's interior. The other outer flange is secured to an opening in a wall of the flexible container. The joined fitment and container are presterilized prior to filling. Selected materials for the multi-ply container walls and the fitment permit the container to withstand gamma ray and other sterilization treatment, heat and pressure while maintaining required strength. After the container is aseptically filled, such as with flowable food product, the fill tube is withdrawn and a lid is hermetically sealed onto the rim of the fitment. A heat shield adjacent a container wall surrounds the fitment to protect the container from excessive heat generated by the associated filling apparatus during filling

  9. 99Tcm-MDP imaging for the diagnosis of joint infection after total hip arthroplasty

    International Nuclear Information System (INIS)

    Li Yuan; Wang Qian; Yue Minggang

    2013-01-01

    Objective: To investigate the value of 99 Tc m -MDP imaging for the differential diagnosis between infection and aseptic loosening after total hip arthroplasty. Methods: During February 2008 to August 2011, 74 patients (32 males, 42 females, average age (64.3±11.2) years) with hip pain after arthroplasty underwent 3-phase (blood flow, blood pool and bone phases) 99 Tc m -MDP imaging. All patients had measurements of serum C reactive protein (CRP) and erythrocyte sedimentation rate (ESR). Joint infection was defined as either increased peri-prosthetic soft tissue activity during perfusion and blood pool phases or increased peri-prosthetic bone activity during uptake phase, or positive in all 3 phases. Aseptic loosening was defined as having negative 99 Tc m -MDP in all 3 phases. Clinical diagnosis was chosen as the gold standard. The blood flow-pool imaging was compared with the serum examinations. χ 2 test was used for statistical analysis. Results: There were 74 symptomatic joints in 74 patients, including 24 joint infections and 50 aseptic loosening. For the detection of peri-prosthetic infection, combined perfusion-blood-pool phase was more accurate than bone uptake phase (90.5% (67/74) vs 55.4% (41/74); χ 2 =23.159, P<0.001), with the sensitivity of 91.7% (22/24) vs 70.8% (17/24) and specificity of 90.0% (45/50) vs 48.0% (24/50), respectively. The blood flow-pool imaging was also more accurate than CRP (73.0% (54/74); χ 2 =7.656, P<0.05) and ESR (71.6% (53/74); χ 2 =8.633, P<0.05), respectively. Conclusion: 99 Tc m -MDP perfusion/blood flow-pool imaging is an accurate modality for differentiating peri-prosthetic infection from aseptic loosening in patients with hip pain after arthroplasty. (authors)

  10. TWO-STAGE REVISION HIP REPLACEMENT PATIENS WITH SEVERE ACETABULUM DEFECT (CASE REPORT

    Directory of Open Access Journals (Sweden)

    V. V. Pavlov

    2017-01-01

    Full Text Available Favorable short-term results of arthroplasty are observed in 80–90% of cases, however, over the longer follow up period the percentage of positive outcomes is gradually reduced. Need for revision of the prosthesis or it’s components increases in proportion to time elapsed from the surgery. In addition, such revision is accompanied with a need to substitute the bone defect of the acetabulum. As a solution the authors propose to replace pelvic defects in two stages. During the first stage the defect was filled with bone allograft with platelet-rich fibrin (allografting with the use of PRF technology. After the allograft remodeling during the second stage the revision surgery is performed by implanting standard prostheses. The authors present a clinical case of a female patient with aseptic loosening of acetabular component of prosthesis in the right hip joint, with failed hip function of stage 2, right limb shortening of 2 cm. Treatment results confirm the efficiency and rationality of the proposed bone grafting option. The authors conclude bone allograft in combination with the PRF technology proves to be an alternative to the implantation of massive metal implants in the acetabulum while it reduces the risk of implant-associated infection, of metallosis in surrounding tissues and expands further revision options.

  11. An in vivo study on the effect of coating stability on osteointegration performance of collagen/hyaluronic acid multilayer modified titanium implants.

    Science.gov (United States)

    Ao, Haiyong; Zong, Jiajia; Nie, Yanjiao; Wan, Yizao; Zheng, Xiebin

    2018-03-01

    Aseptic loosening of implant is one of the main causes of Ti-based implant failure. In our previous work, a novel stable collagen/hyaluronic acid (Col/HA) multilayer modified titanium coatings (TCs) was developed by layer-by-layer (LBL) covalent immobilization technique, which showed enhanced biological properties compared with TCs that were physically absorbed with Col/HA multilayer in vitro . In this study, a rabbit model with femur condyle defect was employed to compare the osteointegration performance of them. Results indicated that Col/HA multilayer with favourable stability could better facilitate osteogenesis around implants and bone-implant contact. The Col/HA multilayer covalent-immobilized TC may reduce aseptic loosening of implant.

  12. Delayed cementless total hip arthroplasty for neglected dislocation of hip combined with complex acetabular fracture and deficient bone stock

    Directory of Open Access Journals (Sweden)

    Gavaskar Ashok S

    2012-12-01

    Full Text Available 【Abstract】Total hip arthroplasty (THA for an un-treated acetabular fracture is technically challenging and the long-term result is not so favorable. A 45-year-old fe-male patient with untreated column and comminuted poste-rior wall fracture of the acetabulum was treated in our insti-tution by reconstruction of the posterior wall using iliac strut autograft and plate stabilization of the posterior col-umn with cancellous grafting and cementless THA in a single stage. At 3 years’ follow-up, the patient was independently mobile without limb length discrepancy. Radiological evalu-ation showed well integrated components and bone grafts. No evidence of aseptic loosening or osteolysis was found. This report aims to emphasize that bony acetabular recon-struction allows the use of primary hip components, which improves prosthesis longevity and preserves bone stock for a future revision. Key words: Acetabulum; Fractures, bone; Hip dislocation; Arthroplasty, replacement, hip

  13. The Angelchik prosthesis

    International Nuclear Information System (INIS)

    Fargnoli, R.; Bozza, A.; Magnoli, A.; Villari, N.; Pernice, L.M.; Andreoli, F.; Lombardi, P.

    1989-01-01

    The Angelchik prosthesis is used in the surgical treatment of gastroesophageal reflux. Operated patients are preliminary examined with imaging techniques, but manometric and acidometric techniques are also used. Although the conventional esophagogram still maintains its diagnostic significance, Computed Tomography (CT) has become the first-choice imaging modality. CT allows the correct evaluation of both the state of the prosthesis and its relationship to the esophagus and gastric fundus. The possible postoperative complications following an incorrect placement of the prosthesis can be accurately diagnosed too. The authors report their experience in the study of 5 patients examined with both conventional radiology and CT

  14. Loosening and damage mechanism of thread-joined structures in nuclear power equipment

    International Nuclear Information System (INIS)

    Tang Hui

    1999-01-01

    The author proposes a loosening mechanism of thread-joined structures under vibrate environments in the nuclear power equipment and structures, which is on the base of the macro and imperceptible-mechanics analysis. It has answered the problems on the seizing, the adhesive wearing, the generation of cracks, the thread-tooth fracture. So it has a conclusion that the loosening of thread-joined structures is essential trend, in other words, the locking property of thread-pair is failure under vibrate environments

  15. [Recurrent aseptic meningitis secondary to taking ibuprofen and ketorolac].

    Science.gov (United States)

    Cano Vargas-Machuca, E; Mondéjar-Marín, B; Navarro-Muñoz, S; Pérez-Molina, I; Garrido-Robres, J A; Alvarez-Tejerina, A

    Aseptic meningitis is a process that is characterised by an inflammatory reaction of the meninges that is not due to any infectious agent. Its aetiology is varied and is most frequently caused by rheumatologic and/or autoimmune processes, chemical or medication-induced meningitis, the most notable drugs involved being antibiotics and non-steroidal anti-inflammatory drugs (NSAI). We report the case of a 70-year-old male, with no relevant history, who was admitted to hospital five times over a period of 16 months because of acute meningitis with polymorphonuclear pleocytosis, high protein levels in cerebrospinal fluid and normal glucose in cerebrospinal fluid. No evidence of an infectious causation, chemical meningitis, carcinomatosis or autoimmune disease was found and the patient was diagnosed with recurrent aseptic meningitis. It was found that the patient had taken ibuprofen or ketorolac on several occasions, a few hours before the appearance of symptoms. These episodes were quickly resolved after withdrawal of this medication. A number of NSAI have been reported as inducers of aseptic meningitis, one of the most notable being ibuprofen. We report the case of a patient who, as a consequence of taking ibuprofen and ketorolac, presented episodes of recurrent aseptic meningitis. To our knowledge this side effect of ketorolac has not been reported before. Its clinical features are impossible to differentiate from those of infectious meningitis. Diagnosis is reached by exclusion and a careful pharmacological study, including over-the-counter drugs like some of the NSAI, must be performed in patients with this condition, since it is a problem that can easily be solved by withdrawing the drug that causes it.

  16. Quality comparison of continuous steam sterilization segmented-flow aseptic processing versus conventional canning of whole and sliced mushrooms.

    Science.gov (United States)

    Anderson, N M; Walker, P N

    2011-08-01

    This study was carried out to investigate segmented-flow aseptic processing of particle foods. A pilot-scale continuous steam sterilization unit capable of producing shelf stable aseptically processed whole and sliced mushrooms was developed. The system utilized pressurized steam as the heating medium to achieve high temperature-short time processing conditions with high and uniform heat transfer that will enable static temperature penetration studies for process development. Segmented-flow technology produced a narrower residence time distribution than pipe-flow aseptic processing; thus, whole and sliced mushrooms were processed only as long as needed to achieve the target F₀  = 7.0 min and were not overcooked. Continuous steam sterilization segmented-flow aseptic processing produced shelf stable aseptically processed mushrooms of superior quality to conventionally canned mushrooms. When compared to conventionally canned mushrooms, aseptically processed yield (weight basis) increased 6.1% (SD = 2.9%) and 6.6% (SD = 2.2%), whiteness (L) improved 3.1% (SD = 1.9%) and 4.7% (SD = 0.7%), color difference (ΔE) improved 6.0% (SD = 1.3%) and 8.5% (SD = 1.5%), and texture improved 3.9% (SD = 1.7%) and 4.6% (SD = 4.2%), for whole and sliced mushrooms, respectively. Segmented-flow aseptic processing eliminated a separate blanching step, eliminated the unnecessary packaging of water and promoted the use of bag-in-box and other versatile aseptic packaging methods. Segmented-flow aseptic processing is capable of producing shelf stable aseptically processed particle foods of superior quality to a conventionally canned product. This unique continuous steam sterilization process eliminates the need for a separate blanching step, reduces or eliminates the need for a liquid carrier, and promotes the use of bag-in-box and other versatile aseptic packaging methods. © 2011 Institute of Food Technologists®

  17. [Recostruction of Extensive Acetabular Defects by Bioactive Glass Ceramics in Re-operations of Total Endoprostheses.].

    Science.gov (United States)

    Urban, K; Sponer, P

    1998-01-01

    The authors made 37 revisions on account of aseptic loosening of total endoprostheses of the hip joint using bioactive glass ceramics BAS-0 of Lasak Co. Prague. For reconstruction of large defects of the acetabulum they used a combination of different types of anti-protrusion metal baskets and granules from this material. In some instances the glass ceramic material was combined with autologous spongiosa. The longest follow-up period is over 4 years. In no instance loosening of the glass ceramic material occurred or its expulsion. All reconstructed sockets of hip joints were burdened by the patients from the third month after surgery. Harris Hip Score before operation was on average 52. During the last checkups of the patients it reached the level of 86. The authors mention complications associated with the procedure. The advantages and disadvantages of the procedure are discussed. Key words: bioactive glass ceramics, reconstruction of acetabular defect, aseptic loosening of endoprosthesis.

  18. [A primary application and evaluation of temporomandibular joint replacement with stock prosthesis].

    Science.gov (United States)

    Zhang, Xiao-hu; Chen, Min-jie; Qiu, Ya-ting; Yang, Chi

    2012-06-01

    To evaluate the effect of total joint replacement in treatment of temporomandibular joint(TMJ) osteoarthropathy with stock prostheses. Six female patients involving 10 joints (2 unilateral and 4 bilateral), with an average age of 59 years old, were involved in this study. Three patients (5 joints) were diagnosed as internal derangement in V stage depending on MRI, 3D-CT findings and clinical characteristics. The other 3 patients (5 joints) had histories of failed temporomandibular joint operation using costochondral graft or temporalis fascial flap. The maximal mouth opening was 1.9 cm on average (range, 1.0 to 2.9cm). All the joints were replaced with Biomet standard prosthesis under general anesthesia. The follow-up period was from 7 to 49 months (average, 17.5 months). All the operations were successfully performed. Heterotopic ossification happened in a bilateral case 1 year postoperatively. One patient with bilateral joint disease complained of severe uncomfortable feeling in the region of the ears and the temples, although there was no significant positive signs according to an ENT examination. Pain relief of the joint and mouth opening improvement were significant in 4 patients. No failure was noted secondary to infection or loosening of the prostheses. The occlusal relationship kept stable postoperatively in all cases. Total TMJ joint replacement with standard prosthesis is a good choice for TMJ reconstruction. It can significantly reduce joint pain and the mouth opening limitation resulted from osteoarthritis. Long-term result remains to be evaluated based on a long-term follow-up.

  19. Mumps vaccine virus strains and aseptic meningitis.

    Science.gov (United States)

    Bonnet, Marie-Claude; Dutta, Anil; Weinberger, Clement; Plotkin, Stanley A

    2006-11-30

    Mumps immunization can easily be included in national schedules, particularly if combined with measles or measles and rubella vaccines, but debate continues concerning the relative safety of various licensed mumps vaccine strains. The opportunities for control of mumps are also being affected by differences in the cost of the vaccines prepared with different strains of mumps virus. The present report evaluates available data on the association of the Urabe and other strains of mumps vaccine with the occurrence of aseptic meningitis. We also review the comparative immunogenicity and efficacies of the most widely used mumps vaccines in controlled clinical trials and field evaluations, and briefly examine relative cost as it relates to the implementation of national immunization programs. We conclude that extensive experience with the most widely used mumps vaccine strains in many countries has shown that the risk-benefit ratio of live mumps vaccines is highly favourable for vaccination, despite the occasional occurence of aseptic meningitis.

  20. Aseptic necrosis of femoral head complicating thalassemia

    International Nuclear Information System (INIS)

    Orzincolo, C.; Castaldi, G.; Scutellary, P.N.; Bariani, L.; Pinca, A.

    1986-01-01

    Aseptic necrosis of the femoral head is described in 4 patients, selected from 280 patients with homozygous β-thalassemia (Cooley anemia). The incidence of the complication appears to be very high (14.5per mille) in thalassemia, compared to the general population. The possible mechanism are discussed. (orig.)

  1. Ten Year Follow-Up of Gap Balanced, Rotating Platform Total Knee Arthroplasty in Patients Under 60 Years of Age.

    Science.gov (United States)

    Lee, Jason H; Barnett, Steven L; Patel, Jay J; Nassif, Nader A; Cummings, Dennis J; Gorab, Robert S

    2016-01-01

    68 patients (91 primary total knee arthroplasties) were evaluated at a mean 10-year, minimum 5 year follow up in patients younger than sixty years of age utilizing the gap balanced, rotating platform design. Follow up assessment included implant survivorship, adverse events, x-rays, Knee Society rating system and clinical evaluation. Three revisions were performed with only one for aseptic loosening at 45 months. Two manipulations were performed in the early postoperative period. Survivorship of the rotating platform, gap balanced knee was 96.7% using surgical revision for any reason and 98.9% using aseptic loosening as endpoints. The rotating platform design using the gap balancing technique in young patients had excellent survivorship at 10-year mean follow up. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Extramedullary spinal teratoma presenting with recurrent aseptic meningitis.

    Science.gov (United States)

    Mpayo, Lucy L; Liu, Xiao-Hong; Xu, Man; Wang, Kai; Wang, Jiao; Yang, Li

    2014-06-01

    Spinal teratomas are extremely rare; they constitute meningitis. A 7-year-old boy presented with paroxysmal abdominal pain and a history of recurrent aseptic meningitis. Kernig and Brudzinski signs were present. Lumber puncture revealed pleocytosis with no evidence of bacteria growth. Imaging of the spine revealed a cystic lesion in spinal cord at thoracic level 9-11. Endoscopic excision of the cyst was successfully performed. Surgical and histopathological findings confirmed extramedullary matured teratoma. As the symptomatic attacks of spontaneous rupture of spinal teratoma resemble presentations of Mollaret meningitis, spinal teratoma should be considered in the differential diagnosis of Mollaret meningitis. We describe a rare example of spinal teratoma causing recurrent meningitis. Spine imaging should be considered in individuals with recurrent aseptic meningitis as this promotes earlier diagnosis, more appropriate treatment, and improved neurological outcome. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Bipolar hip arthroplasty as salvage treatment for loosening of the acetabular cup with significant bone defects

    Directory of Open Access Journals (Sweden)

    Ghanem, Mohamed

    2016-04-01

    Full Text Available Introduction: Revision arthroplasty of the hip is becoming increasingly important in recent years. Early primary arthroplasty and longer life expectancy of the patients increases the number of revision surgery. Revision surgery of hip arthroplasty is major surgery for the patients, especially the elderly, with significant risks concerning the general condition of the patient. The aim of this work is to evaluate the outcome of bipolar hip arthroplasty as a salvage procedure for treatment of loosening of the acetabular cup with significant acetabular bone defects after total hip replacement (THR in multi-morbid patients.Patients and methods: During the period from January 1 2007 to December 31 2011 19 revision hip surgeries were performed in , in which the loosened acetabular cup was replaced by a bipolar head. The examined patient group consisted exclusively of female patients with an average of 75 years. The predominant diagnosis was “aseptic loosening” (84.2%. All patients in our study were multi-morbid. We decided to resort to bipolar hip arthroplasty due to the compromised general condition of patients and the major acetabular bone defects, which were confirmed intraoperatively. The postoperative follow-up ranged from 0.5 to 67 months (average 19.1 months. Results: Evaluation of the modified Harris Hip Score showed an overall improvement of the function of the hip joint after surgery of approximately 45%.Surgery was less time consuming and thus adequate for patients with significantly poor general health condition. We noticed different complications in a significant amount of patients (68.4%. The most common complication encountered was the proximal migration of the bipolar head.The rate of revision following the use of bipolar hip arthroplasty in revision surgery of the hip in our patients was high (21%. Despite the high number of complications reported in our study, we have noticed significant improvement of hip joint function as well

  4. Comparative Analysis of Direct Hospital Care Costs between Aseptic and Two-Stage Septic Knee Revision

    Science.gov (United States)

    Kasch, Richard; Merk, Sebastian; Assmann, Grit; Lahm, Andreas; Napp, Matthias; Merk, Harry; Flessa, Steffen

    2017-01-01

    Background The most common intermediate and long-term complications of total knee arthroplasty (TKA) include aseptic and septic failure of prosthetic joints. These complications cause suffering, and their management is expensive. In the future the number of revision TKA will increase, which involves a greater financial burden. Little concrete data about direct costs for aseptic and two-stage septic knee revisions with an in depth-analysis of septic explantation and implantation is available. Questions/Purposes A retrospective consecutive analysis of the major partial costs involved in revision TKA for aseptic and septic failure was undertaken to compare 1) demographic and clinical characteristics, and 2) variable direct costs (from a hospital department’s perspective) between patients who underwent single-stage aseptic and two-stage septic revision of TKA in a hospital providing maximum care. We separately analyze the explantation and implantation procedures in septic revision cases and identify the major cost drivers of knee revision operations. Methods A total of 106 consecutive patients (71 aseptic and 35 septic) was included. All direct costs of diagnosis, surgery, and treatment from the hospital department’s perspective were calculated as real purchase prices. Personnel involvement was calculated in units of minutes. Results Aseptic versus septic revisions differed significantly in terms of length of hospital stay (15.2 vs. 39.9 days), number of reported secondary diagnoses (6.3 vs. 9.8) and incision-suture time (108.3 min vs. 193.2 min). The management of septic revision TKA was significantly more expensive than that of aseptic failure ($12,223.79 vs. $6,749.43) (p costs of explantation stage ($4,540.46) were lower than aseptic revision TKA ($6,749.43) which were again lower than those of the septic implantation stage ($7,683.33). All mean costs of stays were not comparable as they differ significantly (p cost drivers were the cost of the implant and

  5. Detection of fastener loosening in simple lap joint based on ultrasonic wavefield imaging

    Science.gov (United States)

    Gooda Sahib, M. I.; Leong, S. J.; Chia, C. C.; Mustapha, F.

    2017-12-01

    Joints in aero-mechanical structures are critical elements that ensure the structural integrity but they are prone to damages. Inspection of such joints that have no prior baseline data is really challenging but it can be possibly done using the Ultrasonic Propagation Imager (UPI). The feasibility of applying UPI for detection of loosened fastener is investigated in this study. A simple lap joint specimen made by connecting two pieces of 2.5mm thick SAE304 stainless steel plates using five M6 screws and nuts has been used in this study. All fasteners are tightened to 10Nm but one of them is completely loosened to simulate the damage. The wavefield data is processed into ultrasonic wavefield propagation video and a series of spectral amplitude images. The spectral images showed noticeable amplitude difference at the loosened fastener, hence confirmed the feasibility of using UPI for structural joints inspection. A simple contrast maximization method is also introduced to improve the result.

  6. Magnetic resonance imaging in the evaluation of patients with aseptic meningoencephalitis and connective tissue disorders

    Energy Technology Data Exchange (ETDEWEB)

    Appenzeller, Simone; Kobayashi, Eliane; Costallat, Lilian T.L.; Zanardi, Veronica de Araujo; Ribeiro Neto, Jose Menezes; Damasceno, Benito Pereira; Cendes, Fernando [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Ciencias Medicas

    2000-03-01

    To describe the role of magnetic resonance imaging (MRI) in the evaluation of patients with chronic and recurrent aseptic meningitis. Method: A retrospective study of five patients with aseptic meningoencefalitis diagnosed by clinical and CSF findings. CT scans showed without no relevant findings. Results: MRI showed small multifocal lesions hyperintense on T2 weight images and FLAIR, with mild or no gadolinium enhancement, mainly in periventricular and subcortical regions. Meningoencephalitis preceded the diagnosis of the underlying disease in four patients (Behcet's disease or systemic lupus erythematosus). After the introduction of adequate treatment for the rheumatic disease, they did not present further symptoms of aseptic meningoencephalitis. Conclusion: Aseptic meningoencephalitis can be an early presentation of an autoimmune disease. It is important to emphasize the role of MRI in the diagnosis and follow-up of these patients. (author)

  7. Magnetic resonance imaging in the evaluation of patients with aseptic meningoencephalitis and connective tissue disorders

    International Nuclear Information System (INIS)

    Appenzeller, Simone; Kobayashi, Eliane; Costallat, Lilian T.L.; Zanardi, Veronica de Araujo; Ribeiro Neto, Jose Menezes; Damasceno, Benito Pereira; Cendes, Fernando

    2000-01-01

    To describe the role of magnetic resonance imaging (MRI) in the evaluation of patients with chronic and recurrent aseptic meningitis. Method: A retrospective study of five patients with aseptic meningoencefalitis diagnosed by clinical and CSF findings. CT scans showed without no relevant findings. Results: MRI showed small multifocal lesions hyperintense on T2 weight images and FLAIR, with mild or no gadolinium enhancement, mainly in periventricular and subcortical regions. Meningoencephalitis preceded the diagnosis of the underlying disease in four patients (Behcet's disease or systemic lupus erythematosus). After the introduction of adequate treatment for the rheumatic disease, they did not present further symptoms of aseptic meningoencephalitis. Conclusion: Aseptic meningoencephalitis can be an early presentation of an autoimmune disease. It is important to emphasize the role of MRI in the diagnosis and follow-up of these patients. (author)

  8. Magnetic resonance imaging in the evaluation of patients with aseptic meningoencephalitis and connective tissue disorders

    Directory of Open Access Journals (Sweden)

    APPENZELLER SIMONE

    2000-01-01

    Full Text Available OBJECTIVE: To describe the role of magnetic resonance imaging (MRI in the evaluation of patients with chronic and recurrent aseptic meningitis.METHOD: A retrospective study of five patients with aseptic meningoencefalitis diagnosed by clinical and CSF findings. CT scans showed without no relevant findings. RESULTS: MRI showed small multifocal lesions hyperintense on T2 weighted images and FLAIR, with mild or no gadolinium enhancement, mainly in periventricular and subcortical regions. Meningoencephalitis preceded the diagnosis of the underlying disease in four patients (Behçet´s disease or systemic lupus erythematosus. After the introduction of adequate treatment for the rheumatic disease, they did not present further symptoms of aseptic meningoencephalitis. CONCLUSION: Aseptic meningoencephalitis can be an early presentation of an autoimmune disease. It is important to emphasize the role of MRI in the diagnosis and follow-up of these patients.

  9. EFFECT OF PASTEURIZATION TEMPERATURE AND ASEPTIC FILLING ON THE SHELF-LIFE OF MILK

    Directory of Open Access Journals (Sweden)

    Rodrigo Rodrigues PETRUS

    2011-12-01

    Full Text Available Aseptic filling process can contribute to extend the shelf-life of pasteurized milk. However, this technology is not still commercially practiced in Brazil for this product. The aim of this study was to evaluate the effect of the pasteurization temperature and aseptic filling on the stability of milk packaged in high density polyethylene bottle (HDPE. Three batches of one hundred bottles each were processed at 72, 83, and 94ºC/15s, followed by aseptic packaging and storage at 9ºC, simulating a deficient cold chain scenario as found in the Brazilian market. Microbiological stability evaluation was based on mesophilic and psychrotrophic counts. Sensory shelf-life was estimated according to the ratings assigned to the attributes appearance, aroma, flavor and overall appreciation of milk samples. The pasteurization temperature, in the range investigated, did not affect the shelf-life of milk, which lasted up to 11 days for the three processed batches. The aseptic filling, associated to the employed thermal treatments, did not extend the shelf-life of milk stored under the abuse condition of 9°C, considering that the commercial product shelf-life in Brazil is of about 10 days.

  10. Risk factors for total hip arthroplasty aseptic revision.

    Science.gov (United States)

    Khatod, Monti; Cafri, Guy; Namba, Robert S; Inacio, Maria C S; Paxton, Elizabeth W

    2014-07-01

    The purpose of this study was to evaluate patient, operative, implant, surgeon, and hospital factors associated with aseptic revision after primary THA in patients registered in a large US Total Joint Replacement Registry. A total of 35,960 THAs registered from 4/2001-12/2010 were evaluated. The 8-year survival rate was 96.7% (95% CI 96.4%-97.0%). Females had a higher risk of aseptic revision than males. Hispanic and Asian patients had a lower risk of revision than white patients. Ceramic-on-ceramic, ceramic-on-conventional polyethylene, and metal-on-conventional polyethylene bearing surfaces had a higher risk of revision than metal-on-highly cross-linked polyethylene. Body mass index, health status, diabetes, diagnosis, fixation, approach, bilateral procedures, head size, surgeon fellowship training, surgeon and hospital volume were not revision risk factors. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Outcomes of Modified Harrington Reconstructions for Nonprimary Periacetabular Tumors: An Effective and Inexpensive Technique.

    Science.gov (United States)

    Bernthal, Nicholas M; Price, Shawn L; Monument, Michael J; Wilkinson, Brandon; Jones, Kevin B; Randall, R Lor

    2015-11-01

    Metastatic disease to the acetabulum presents a difficult technical and philosophical challenge: complicated surgeries in patients with often short life expectancies force us to examine both the outcome and cost of these operations. Therefore, we studied the durability of a cement-screw rebar reconstruction technique and risk factors for failure, and we compare the results to other reconstruction options. This is a retrospective review of 52 acetabular reconstructions in 50 patients for nonprimary disease using a retrograde screw-rebar-cement all-polyethylene technique. Mean age was 57 years (range 25-81 years). Twenty-four lesions were classified as Harrington class II; 28 were Harrington class III. Mean follow-up was 17.7 months (range 1-92 months). Outcomes included patient survival, prosthesis survival, and complications. Forty-eight of 50 (96 %) patients ambulated after surgery. Five of 52 (9.6 %) of prostheses failed, three from loosening due to tumor progression, one from aseptic loosening, and one from soft tissue instability (dislocation). The three cases of tumor progression failure occurred in patients with massive preoperative ischial tumor burden. Mean surgical time was 198 min, and hospital stay was 5.2 days. The screw-cement-rebar all-polyethylene cup reconstruction technique is a comparatively successful and inexpensive reconstruction option for treating nonprimary oncologic disease in the acetabulum. All cases of loosening occurred beyond the median patient survival. Surgeons should be wary of massive ischial tumor burden in patients with projected longevity, as it may be associated with implant failure. Surgical time and hospital stay are consistent with historical data for alternative implants, and implant cost is lower.

  12. Nasal prosthesis rehabilitation: a case report

    DEFF Research Database (Denmark)

    Jain, Sumeet; Maru, Kavita; Shukla, Jyotsana

    2011-01-01

    Facial defects resulting from neoplasm, congenital malformation or trauma can be restored with facial prosthesis using different materials and retention methods to achieve life-like look and function. A nasal prosthesis can re-establish esthetic form and anatomic contours for mid-facial defects...... the non-surgical rehabilitation, with polymethyl meth-acrylate resin, nasal prosthesis for a patient who received partial rhinectomy as a result of squamous cell carcinoma of the nose. The prosthesis was made to restore the esthetic appearance of the patient with a mechanical retained design using...

  13. Effect of age on the incidence of aseptic meningitis following immunization with monovalent mumps vaccine.

    Science.gov (United States)

    Muta, Hiromi; Nagai, Takao; Ito, Yuhei; Ihara, Toshiaki; Nakayama, Tetsuo

    2015-11-09

    The purpose of this study was to determine the risk of aseptic meningitis after mumps vaccination in younger children compared with older children. This prospective cohort study included a total of 21,465 children under 18 years of age who had received the first dose of three of the Japanese mumps monovalent vaccine. We compared the cumulative incidence of aseptic meningitis for 30 days after vaccination among the following age groups: ≤ 1, 2, 3-4, and ≥ 5 years old. We also investigated the cumulative incidence of salivary gland swelling, a fever (≥ 38°C) lasting at least 3 days during the 10 to 25 days following immunization, vomiting of 3 times or more, headache, and seizure. A total of 10 aseptic meningitis, 551 salivary gland swelling, 844 fevers, 669 vomiting, 757 headaches, and 29 seizure cases were identified. The cumulative incidence of aseptic meningitis increased with age (0.016%, 0.021%, 0.066%, and 0.096%, respectively). Statistical significance was observed between children ≥ 3 years old and those mumps vaccine that is currently available for use in Japan may be administered in children less than 3 years of age in order to complicate a less aseptic meningitis after immunization. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. A financial analysis of revision hip arthroplasty: the economic burden in relation to the national tariff.

    Science.gov (United States)

    Vanhegan, I S; Malik, A K; Jayakumar, P; Ul Islam, S; Haddad, F S

    2012-05-01

    Revision arthroplasty of the hip is expensive owing to the increased cost of pre-operative investigations, surgical implants and instrumentation, protracted hospital stay and drugs. We compared the costs of performing this surgery for aseptic loosening, dislocation, deep infection and peri-prosthetic fracture. Clinical, demographic and economic data were obtained for 305 consecutive revision total hip replacements in 286 patients performed at a tertiary referral centre between 1999 and 2008. The mean total costs for revision surgery in aseptic cases (n = 194) were £11 897 (sd 4629), for septic revision (n = 76) £21 937 (sd 10 965), for peri-prosthetic fracture (n = 24) £18 185 (sd 9124), and for dislocation (n = 11) £10 893 (sd 5476). Surgery for deep infection and peri-prosthetic fracture was associated with longer operating times, increased blood loss and an increase in complications compared to revisions for aseptic loosening. Total inpatient stay was also significantly longer on average (p < 0.001). Financial costs vary significantly by indication, which is not reflected in current National Health Service tariffs.

  15. Patellofemoral Joint Replacement and Nickel Allergy: An Unusual Presentation

    Directory of Open Access Journals (Sweden)

    Farhan Syed

    2015-01-01

    Full Text Available Metal allergy is an unusual complication of joint replacement that may cause aseptic loosening and necessitate joint revision surgery. We present the case of nickel allergy causing aseptic loosening following patellofemoral joint replacement (PFJR in a 54-year-old male. Joint revision surgery to a nickel-free total knee replacement was performed with good results. Our literature review shows that there is no evidence to guide the management of metal allergy in PFJR. The evidence from studies of total knee replacement is limited to retrospective case series and case reports and gives contradictory recommendations. The optimal management strategy for metal allergy in PFJR is not clear. We recommend allergy testing in patients with history of metal allergy and use of an allergen-free implant in those with positive tests. As there is no gold standard test to establish metal allergy, the choice of test should be guided by availability and recommendation from the local unit of dermatology and allergy testing. We recommend investigation for metal allergy in patients with implant loosening where other causes have been excluded.

  16. Aseptic necrosis in caisson workers: a new set of decompression tables.

    Science.gov (United States)

    Downs, G J; Kindwall, E P

    1986-06-01

    There is a high incidence of aseptic necrosis and decompression sickness among caisson workers due to inadequate decompression using the current OSHA decompression tables (1-7). Because of this, a new set of tables--Autodec III-O2--was developed which more effectively eliminates nitrogen from the body and, therefore, should decrease the incidence of both bends and aseptic necrosis. The Autodec III-O2 schedule's superiority was statistically significant at a level of 0.08 compared to the OSHA table. It is our conclusion that OSHA should adopt the Autodec III-O2 schedule as a replacement for the current decompression tables.

  17. Comparison of Range of Motion After Total Knee Prosthesis According to Different Type of Prosthesis

    Directory of Open Access Journals (Sweden)

    Firat Seyfettinoglu

    2016-07-01

    Full Text Available Aim: The aim of this study is to determine the effectiveness and range of motion of different type of knee prosthesis. Material and Method: This study includes 180 of 225 patients (139 F, 41 M, average age: 65, range of age: 51-82 between April 2005 and September 2007 with the diagnosis of gonarthrosis. All patients underwent to primary total knee arthroplasty. Primary osteoartrhritis is the reason of gonarthrosis. The patients with secondary osteoartrhritis were excluded from the study. All the patients were operated by the same surgical team and rehabilitated after surgery. Patella didnt change any patient. PCL was protected in some of the patients and cut some of patients. Totally seven type prosthesis in 16 subgroup were applied to the patients. All measurement were done by the same surgeon. Average follow up period was 31 months (24-49 months. Results: Patients without subgrouping were tested according to the range of motion before and after surgery to the type of the prosthesis trademark. Range of motion was decreased with the usage of Rotaglide and LCS® type of prosthesis. Range of motion didnt change with the usage of Maxim and Kinemax type. The range of motion increased in the other trademark of prosthesis. Flexion angle was increased statistically significant with nexgen® and scorpio® prosthesis (p

  18. The effect of polyethylene creep on tibial insert locking screw loosening and back-out in prosthetic knee joints.

    Science.gov (United States)

    Sanders, Anthony P; Raeymaekers, Bart

    2014-10-01

    A prosthetic knee joint typically comprises a cobalt-chromium femoral component that articulates with a polyethylene tibial insert. A locking screw may be used to prevent micromotion and dislodgement of the tibial insert from the tibial tray. Screw loosening and back-out have been reported, but the mechanism that causes screw loosening is currently not well understood. In this paper, we experimentally evaluate the effect of polyethylene creep on the preload of the locking screw. We find that the preload decreases significantly as a result of polyethylene creep, which reduces the torque required to loosen the locking screw. The torque applied to the tibial insert due to internal/external rotation within the knee joint during gait could thus drive locking screw loosening and back-out. The results are very similar for different types of polyethylene. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Recurrent aseptic meningitis in association with Kikuchi-Fujimoto disease: case report and literature review

    Directory of Open Access Journals (Sweden)

    Komagamine Tomoko

    2012-09-01

    Full Text Available Abstract Background Kikuchi Fujimoto disease (KFD, or histiocytic necrotising lymphadenitis, is a benign and self-limiting condition characterised by primarily affecting the cervical lymph nodes. Recurrent aseptic meningitis in association with KFD is extremely rare and remains a diagnostic challenge. Case presentation We report a 28-year-old man who presented 7 episodes of aseptic meningitis associated with KFD over the course of 7 years. Histopathological findings of enlarged lymph nodes led to the diagnosis of KFD. The patient’s headache and lymphadenopathy spontaneously resolved without any sequelae. Conclusions A diagnosis of KFD should be considered when enlarged cervical lymph nodes are observed in patients with recurrent aseptic meningitis. A long-term prognosis remains uncertain, and careful follow-up is preferred.

  20. Implant-Retained Auricular Prosthesis: A Case Report

    OpenAIRE

    Ozturk, A. Nilgun; Usumez, Aslihan; Tosun, Zekeriya

    2010-01-01

    Extraoral implant retained prosthesis have been proven to be a predictable treatment option for maxillofacial rehabilitation. This case report describes the clinical and laboratory procedures for fabricating an auricular prosthesis. In this case report, an auricular prosthesis was fabricated for a patient who lost the left and right external ear in an electrical burn. Extraoral implants and bar-and-clip retention for the proper connection of the auricular prosthesis to implant were used. This...

  1. Permanent Quadriplegia Following Replacement of Voice Prosthesis.

    Science.gov (United States)

    Ozturk, Kayhan; Erdur, Omer; Kibar, Ertugrul

    2016-11-01

    The authors presented a patient with quadriplegia caused by cervical spine abscess following voice prosthesis replacement. The authors present the first reported permanent quadriplegia patient caused by voice prosthesis replacement. The authors wanted to emphasize that life-threatening complications may be faced during the replacement of voice prosthesis. Care should be taken during the replacement of voice prosthesis and if some problems have been faced during the procedure patients must be followed closely.

  2. Laser-assisted fixation of a nitinol stapes prosthesis.

    Science.gov (United States)

    Schrötzlmair, Florian; Suchan, Fabian; Pongratz, Thomas; Krause, Eike; Müller, Joachim; Sroka, Ronald

    2018-02-01

    Otosclerosis is an inner ear bone disease characterized by fixation of the stapes and consequently progressive hearing loss. One treatment option is the surgical replacement of the stapes by a prosthesis. When so called "smart materials" like nitinol are used, prosthesis fixation can be performed using a laser without manual crimping on the incus. However, specific laser-prosthesis interactions have not been described yet. The aim of the present study was to elucidate the thermo-mechanical properties of the NiTiBOND® prosthesis as a basis for handling instructions for laser-assisted prosthesis fixation. Closure of the NiTiBOND® prosthesis was induced ex vivo by either a diode laser emitting at λ = 940 nm or a CO 2 laser (λ = 10,600 nm). Total energy for closure was determined. Suitable laser parameters (pulse duration, power per pulse, distance between tip of the laser fiber and prosthesis) were assessed. Specific laser-prosthesis interactions were recorded. Especially the diode laser was found to be an appropriate energy source. A total energy deposit of 60 mJ by pulses in near contact application was found to be sufficient for prosthesis closure ex vivo. Energy should be transmitted through a laser fiber equipollent to the prosthesis band diameter. Specific deformation characteristics due to the zonal prosthesis composition have to be taken into account. NiTiBOND® stapes prosthesis can be closed by very little energy when appropriate energy sources like diode lasers are used, suggesting a relatively safe application in vivo. Lasers Surg. Med. 50:153-157, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  3. Total hip arthroplasty survival in femoral head avascular necrosis versus primary hip osteoarthritis: Case-control study with a mean 10-year follow-up after anatomical cementless metal-on-metal 28-mm replacement.

    Science.gov (United States)

    Ancelin, D; Reina, N; Cavaignac, E; Delclaux, S; Chiron, P

    2016-12-01

    Total hip arthroplasty is the most widely used procedure to treat avascular necrosis (AVN) of the femoral head. Few studies have compared the outcomes of THA in femoral head AVN and primary hip osteoarthritis. Therefore we performed a case-control study to compare THA for femoral head AVN vs. primary hip osteoarthritis in terms of: (1) prosthesis survival, (2) complication rates, (3) functional outcomes and radiographic outcomes, (4) and to determine whether specific risk factors for THA failure exist in femoral head AVN. THA survival is similar in femoral head AVN and primary hip osteoarthritis. We compared two prospective cohorts of patients who underwent THA before 65 years of age, one composed of cases with femoral head AVN and the other of controls with primary hip osteoarthritis. In both cohorts, a cementless metal-on-metal prosthesis with a 28-mm cup and an anatomical stem was used. Exclusion criteria were THA with other types of prosthesis, posttraumatic AVN, and secondary osteoarthritis. With α set at 5%, to obtain 80% power, 246 patients were required in all. Prosthesis survival was assessed based on time to major revision (defined as replacement of at least one implant fixed to bone) and time to aseptic loosening. The other evaluation criteria were complications, Postel-Merle d'Aubigné (PMA) score, and the Engh and Agora Radiographic Assessment (ARA) scores for implant osseointegration. The study included 282 patients, 149 with AVN and 133 with osteoarthritis. Mean age was 47.8±10.2 years (range, 18.5-65) and mean follow-up was 11.4±2.8 years (range, 4.5-18.3 years). The 10-year survival rates were similar in the two groups: for major revision, AVN group, 92.5% (95% confidence interval [95% CI], 90.2-94.8) and osteoarthritis group, 95.3% (95% CI, 92.9-97.7); for aseptic loosening, AVN group, 98.6% (95% CI, 97.6-98.6) and osteoarthritis, 99.2% (95% CI, 98.4-100). The AVN group had higher numbers of revision for any reason (19 vs. 6, P=0.018) and

  4. 77 FR 21783 - Guidance on Media Fills for Validation of Aseptic Preparations for Positron Emission Tomography...

    Science.gov (United States)

    2012-04-11

    ...] Guidance on Media Fills for Validation of Aseptic Preparations for Positron Emission Tomography Drugs... Aseptic Preparations for Positron Emission Tomography (PET) Drugs.'' This guidance is intended to help... Preparations for Positron Emission Tomography (PET) Drugs.'' Most PET drugs are designed for parenteral...

  5. Patients with hip prosthesis: radiotherapy treatment planning considerations

    International Nuclear Information System (INIS)

    Ganesh, K.M.; Supe, Sanjay S.

    2000-01-01

    The number of patients with hip prosthesis undergoing radiotherapy for pelvic cancer worldwide is increasing. This might be of importance depending on the materials in the prosthesis and whether any of the treatment fields are involved in the prosthesis. Radiotherapy planning involving the pelvic region of patients having total hip prosthesis has been found to be difficult due to the effect of the prosthesis on the dose distribution. This review is intended to project dosimetric considerations and possible solutions to this uncommon problem

  6. Etiologies and Management of Aseptic Meningitis in Patients Admitted to an Internal Medicine Department.

    Science.gov (United States)

    Jarrin, Irène; Sellier, Pierre; Lopes, Amanda; Morgand, Marjolaine; Makovec, Tamara; Delcey, Veronique; Champion, Karine; Simoneau, Guy; Green, Andrew; Mouly, Stéphane; Bergmann, Jean-François; Lloret-Linares, Célia

    2016-01-01

    Several studies have focused on the clinical and biological characteristics of meningitis in order to distinguish between bacterial and viral meningitis in the emergency setting. However, little is known about the etiologies and outcomes of aseptic meningitis in patients admitted to Internal Medicine.The aim of the study is to describe the etiologies, characteristics, and outcomes of aseptic meningitis with or without encephalitis in adults admitted to an Internal Medicine Department.A retrospective cohort study was conducted in the Internal Medicine Department of the Lariboisière Hospital in Paris, France, from January 2009 to December 2011. Clinical and biological characteristics of aseptic meningitis were recorded. These included cerebrospinal fluid analysis, results of polymerase chain reaction testing, final diagnoses, and therapeutic management.The cohort included 180 patients fulfilling the criteria for aseptic meningitis with (n = 56) or without (n = 124) encephalitis. A definitive etiological diagnosis was established in 83 of the 180 cases. Of the cases with a definitive diagnosis, 73 were due to infectious agents, mainly enteroviruses, Herpes Simplex Virus 2, and Varicella Zoster Virus (43.4%, 16.8%, and 14.5% respectively). Inflammatory diseases were diagnosed in 7 cases. Among the 97 cases without definitive diagnoses, 26 (26.8%) remained free of treatment throughout their management whereas antiviral or antibiotic therapy was initiated in the emergency department for the remaining 71 patients. The treatment was discontinued in only 10 patients deemed to have viral meningitis upon admission to Internal Medicine.The prevalence of inflammatory diseases among patients admitted to internal medicine for aseptic meningitis is not rare (4% of overall aseptic meningitis). The PCR upon admission to the emergency department is obviously of major importance for the prompt optimization of therapy and management. However, meningitis due to viral agents or

  7. 21 CFR 872.3960 - Mandibular condyle prosthesis.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3960 Mandibular condyle prosthesis. (a) Identification. A mandibular condyle prosthesis is a device that is intended to be implanted in the human jaw to... requirement for premarket approval for any mandibular condyle prosthesis intended to be implanted in the human...

  8. Use of next generation sequencing to detect biofilm bacteria in a patient with pedicle screw loosening after spine surgery

    DEFF Research Database (Denmark)

    Xu, Yijuan; Thomsen, Trine Rolighed; Lorenzen, Jan

    2016-01-01

    2. Center for Microbial Communities, Department of Biotechnology, Chemistry and Environmental Engineering, Aalborg University, Denmark 3. Otto-von-Guericke University Magdeburg, Department of Orthopedic Surgery, Magdeburg, Germany 4. Eifelklinik St. Brigida, Simmerath, Germany Aim: ”Hidden deep...... implant-related infection is believed to be linked to pedicle screw loosening after spine surgery. Low-grade bacterial infection can be hard to diagnose and may be undetected by conventional culture based methods. Next generation sequencing (NGS) could help to uncover hidden bacterial infections...... as a possible cause for implant loosening. This case report describes the use of NGS in the diagnostic work-up of a patient with pedicle screw loosening after spine surgery.” Method: ”A 60 y/o male had to undergo revision spine surgery for pedicle screw loosening and adjacent segment disease 3 years after...

  9. Comparison of fixed-bearing and mobile-bearing total knee arthroplasty after high tibial osteotomy.

    Science.gov (United States)

    Hernigou, Philippe; Huys, Maxime; Pariat, Jacques; Roubineau, François; Flouzat Lachaniette, Charles Henri; Dubory, Arnaud

    2018-02-01

    There is no information comparing the results of fixed-bearing total knee replacement and mobile-bearing total knee replacement in the same patients previously treated by high tibial osteotomy. The purpose was therefore to compare fixed-bearing and mobile-bearing total knee replacements in patients treated with previous high tibial osteotomy. We compared the results of 57 patients with osteoarthritis who had received a fixed-bearing prosthesis after high tibial osteotomy with the results of 41 matched patients who had received a rotating platform after high tibial osteotomy. The match was made for length of follow-up period. The mean follow-up was 17 years (range, 15-20 years). The patients were assessed clinically and radiographically. The pre-operative knee scores had no statistically significant differences between the two groups. So was the case with the intra-operative releases, blood loss, thromboembolic complications and infection rates in either group. There was significant improvement in both groups of knees, and no significant difference was observed between the groups (i.e., fixed-bearing and mobile-bearing knees) for the mean Knee Society knee clinical score (95 and 92 points, respectively), or the Knee Society knee functional score (82 and 83 points, respectively) at the latest follow-up. However, the mean post-operative knee motion was higher for the fixed-bearing group (117° versus 110°). In the fixed-bearing group, one knee was revised because of periprosthetic fracture. In the rotating platform mobile-bearing group, one knee was revised because of aseptic loosening of the tibial component. The Kaplan-Meier survivorship for revision at ten years of follow-up was 95.2% for the fixed bearing prosthesis and 91.1% for the rotating platform mobile-bearing prosthesis. Although we did manage to detect significant differences mainly in clinical and radiographic results between the two groups, we found no superiority or inferiority of the mobile

  10. Satisfactory Results of the Exeter Revision Femoral Stem Used for Primary Total Hip Arthroplasty.

    Science.gov (United States)

    Desy, Nicholas M; Johnson, Joshua D; Sierra, Rafael J

    2017-02-01

    The Exeter cemented femoral stem has demonstrated excellent clinical and radiographic outcomes as well as long-term survivorship free from aseptic loosening. A shorter revision stem (125 mm) with a 44 offset became available for the purpose of cement-in-cement revision situations. In certain cases, this shorter revision stem may be used for various primary total hip arthroplasties (THAs) where the standard length stem would require distally reaming the femoral canal. We sought to report on the early to midterm results of this specific stem when used for primary THA regarding (1) clinical and radiographic outcomes, (2) complications, and (3) survivorship. Twenty-nine patients (33 hips) underwent a hybrid THA using the smaller revision Exeter cemented femoral stem. Twenty-five patients (28 hips) had at least 2 years of follow-up and were assessed for clinical and radiographic outcomes. All 33 hips were included in the analysis of complications and survivorship. The Kaplan-Meier survivorship was performed using revision for all causes and for aseptic loosening as the end points. The average clinical follow-up was 4 years (range, 2-7). Harris Hip Scores improved from a mean preoperative value of 56 (range, 23-96) to 90 (range, 51-100) at the latest follow-up. All patients demonstrated superior cement mantles with no signs of loosening. One patient suffered a B2 periprosthetic fracture and 1 patient experienced 2 episodes of instability. The 5-year Kaplan-Meier survivorship was 96.7% for all causes of revision and was 100% using aseptic loosening as the end point. The shorter Exeter revision cemented femoral stem has favorable early to midterm clinical and radiographic outcomes when used for primary THA with a low complication rate and is a viable option in patients with narrow femoral canals where uncemented stem fixation is not desired. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Influence of the implant abutment types and the dynamic loading on initial screw loosening

    Science.gov (United States)

    Kim, Eun-Sook

    2013-01-01

    PURPOSE This study examined the effects of the abutment types and dynamic loading on the stability of implant prostheses with three types of implant abutments prepared using different fabrication methods by measuring removal torque both before and after dynamic loading. MATERIALS AND METHODS Three groups of abutments were produced using different types of fabrication methods; stock abutment, gold cast abutment, and CAD/CAM custom abutment. A customized jig was fabricated to apply the load at 30° to the long axis. The implant fixtures were fixed to the jig, and connected to the abutments with a 30 Ncm tightening torque. A sine curved dynamic load was applied for 105 cycles between 25 and 250 N at 14 Hz. Removal torque before loading and after loading were evaluated. The SPSS was used for statistical analysis of the results. A Kruskal-Wallis test was performed to compare screw loosening between the abutment systems. A Wilcoxon signed-rank test was performed to compare screw loosening between before and after loading in each group (α=0.05). RESULTS Removal torque value before loading and after loading was the highest in stock abutment, which was then followed by gold cast abutment and CAD/CAM custom abutment, but there were no significant differences. CONCLUSION The abutment types did not have a significant influence on short term screw loosening. On the other hand, after 105 cycles dynamic loading, CAD/CAM custom abutment affected the initial screw loosening, but stock abutment and gold cast abutment did not. PMID:23509006

  12. Dosimetry of a silicone breast prosthesis

    International Nuclear Information System (INIS)

    McGinley, P.H.; Powell, W.R.; Bostwick, J.

    1980-01-01

    Dose measurements were conducted in a phantom which simulates breast tissue and in another phantom which simulates a breast containing a silicone prosthesis. No detectable difference was found when the irradiations were carried out with tangential beams of 60 Co radiation. The degree of backscatter and absorption of radiation by the prosthesis and phantom were also similar. A slight decrease in dose of approximately 8% was found at the interface between the prosthesis and muscle-equivalent material

  13. Potential application of quantitative microbiological risk assessment techniques to an aseptic-UHT process in the food industry.

    Science.gov (United States)

    Pujol, Laure; Albert, Isabelle; Johnson, Nicholas Brian; Membré, Jeanne-Marie

    2013-04-01

    Aseptic ultra-high-temperature (UHT)-type processed food products (e.g., milk or soup) are ready to eat products which are consumed extensively globally due to a combination of their comparative high quality and long shelf life, with no cold chain or other preservation requirements. Due to the inherent microbial vulnerability of aseptic-UHT product formulations, the safety and stability-related performance objectives (POs) required at the end of the manufacturing process are the most demanding found in the food industry. The key determinants to achieving sterility, and which also differentiates aseptic-UHT from in-pack sterilised products, are the challenges associated with the processes of aseptic filling and sealing. This is a complex process that has traditionally been run using deterministic or empirical process settings. Quantifying the risk of microbial contamination and recontamination along the aseptic-UHT process, using the scientifically based process quantitative microbial risk assessment (QMRA), offers the possibility to improve on the currently tolerable sterility failure rate (i.e., 1 defect per 10,000 units). In addition, benefits of applying QMRA are (i) to implement process settings in a transparent and scientific manner; (ii) to develop a uniform common structure whatever the production line, leading to a harmonisation of these process settings, and; (iii) to bring elements of a cost-benefit analysis of the management measures. The objective of this article is to explore how QMRA techniques and risk management metrics may be applied to aseptic-UHT-type processed food products. In particular, the aseptic-UHT process should benefit from a number of novel mathematical and statistical concepts that have been developed in the field of QMRA. Probabilistic techniques such as Monte Carlo simulation, Bayesian inference and sensitivity analysis, should help in assessing the compliance with safety and stability-related POs set at the end of the manufacturing

  14. Effect of Storage on Quality and Acceptance of Aseptically ...

    African Journals Online (AJOL)

    Ashgourd (Benincasa hispida) juice was formulated with the help of Response Surface Methodology (RSM) and the storage stability of the juice was investigated. The juice was aseptically processed, sterilized at 137ıC for 4 seconds and packaged in 6 layer laminated packet under sterilized environment.

  15. Customized Knee Prosthesis in Treatment of Giant Cell Tumors of the Proximal Tibia: Application of 3-Dimensional Printing Technology in Surgical Design.

    Science.gov (United States)

    Luo, Wenbin; Huang, Lanfeng; Liu, He; Qu, Wenrui; Zhao, Xin; Wang, Chenyu; Li, Chen; Yu, Tao; Han, Qing; Wang, Jincheng; Qin, Yanguo

    2017-04-07

    BACKGROUND We explored the application of 3-dimensional (3D) printing technology in treating giant cell tumors (GCT) of the proximal tibia. A tibia block was designed and produced through 3D printing technology. We expected that this 3D-printed block would fill the bone defect after en-bloc resection. Importantly, the block, combined with a standard knee joint prosthesis, provided attachments for collateral ligaments of the knee, which can maintain knee stability. MATERIAL AND METHODS A computed tomography (CT) scan was taken of both knee joints in 4 patients with GCT of the proximal tibia. We developed a novel technique - the real-size 3D-printed proximal tibia model - to design preoperative treatment plans. Hence, with the application of 3D printing technology, a customized proximal tibia block could be designed for each patient individually, which fixed the bone defect, combined with standard knee prosthesis. RESULTS In all 4 cases, the 3D-printed block fitted the bone defect precisely. The motion range of the affected knee was 90 degrees on average, and the soft tissue balance and stability of the knee were good. After an average 7-month follow-up, the MSTS score was 19 on average. No sign of prosthesis fracture, loosening, or other relevant complications were detected. CONCLUSIONS This technique can be used to treat GCT of the proximal tibia when it is hard to achieve soft tissue balance after tumor resection. 3D printing technology simplified the design and manufacturing progress of custom-made orthopedic medical instruments. This new surgical technique could be much more widely applied because of 3D printing technology.

  16. The value of 18F-fluoride PET/CT in the assessment of screw loosening in patients after intervertebral fusion stabilization

    International Nuclear Information System (INIS)

    Seifen, Tanja; Rodrigues, Margarida; Rettenbacher, Lukas; Holzmannhofer, Johannes; Pirich, Christian; Piotrowski, Wolfgang; Mc Coy, Mark

    2015-01-01

    We evaluated 18 F-fluoride PET/CT for the diagnosis of screw loosening after intervertebral fusion stabilization and compared the results with those from functional radiography. A group of 59 patients with pain in the region of previous intervertebral fusion stabilization and suspicion of implant instability due to screw loosening were investigated with 18 F-fluoride PET/CT and functional radiography, 30.1 ± 3.4 and 29.3 ± 3.2 months, respectively, after surgery. The criterion for loosening was increased focal uptake surrounding the screw entry point and shaft. SUV max and SUV mean were measured in a region of interest (ROI) drawn around each screw (334 screws analysed). The final diagnosis was established by surgical exploration in 27 patients and clinical follow-up after intervertebral fusion stabilization in 32 patients. Of the 59 patients, 20 were proven positive for implant failure due to screw loosening and 39 were confirmed negative. The sensitivity, specificity and accuracy of 18 F-fluoride PET/CT were 75 %, 97.4 % and 89.8 % in the patient-based analysis, and 45.6 %, 100 % and 80 % in the screw-based analysis, respectively. The positive and negative predictive values were 93.8 % and 100 % in the patient-based analysis, and 88.4 and 76 % in the screw-based analysis, respectively. CT signs in PET/CT allowed screw breakage to be detected in three patients. SUV max , SUV mean and SUV max /SUV mean ratios in screw ROIs and respective values in reference regions were all found to be significantly different between screws positive for loosening (58 screws) and screws negative for loosening (276 screws). The ratio between SUV max in screw ROIs and the values in reference regions was the most significant parameter for distinguishing screws positive and screws negative for loosening. 18 F-Fluoride PET/CT imaging is useful for the diagnosis of screw loosening in patients with persistent symptoms after intervertebral fusion stabilization. (orig.)

  17. Duocentric® reversed shoulder prosthesis and Personal Fit® templates: innovative strategies to optimize prosthesis positioning and prevent scapular notching.

    Science.gov (United States)

    Trouilloud, P; Gonzalvez, M; Martz, P; Charles, H; Handelberg, F; Nyffeler, R W; Baulot, E

    2014-05-01

    We describe our experience with a new system of patient-specific template called Personal Fit(®), which is unique in shoulder surgery and used in combination with Duocentric(®) prosthesis. The reverse prosthesis's concept is the invention of Paul Grammont, developed with Grammont's team of Dijon University as from 1981, which led to the first reversed total shoulder prosthesis called Trumpet in 1985. The Duocentric(®) prosthesis developed in 2001 is the third-generation prosthesis, coming from the Trumpet and the second-generation prosthesis Delta(®) (DePuy). This prosthesis provides a novel solution to the notching problem with an inferior overhang integrated onto the glenoid baseplate. Personal Fit(®) system is based on reconstructing the shoulder joint bones in three dimensions using CT scan data, placing a landmark on the scapula and locating points on the glenoid and humerus. That will be used as a reference for the patient-specific templates. We study the glenoid position planned with Personal Fit(®) software relative to native glenoid position in 30 cases. On average, the difference between the planned retroversion (or anteversion in one case) and native retroversion was 8.6°.

  18. Malrotation of the McGhan Style 510 prosthesis.

    NARCIS (Netherlands)

    Schots, J.M.; Fechner, M.R.; Hoogbergen, M.M.; Tits, H.W.H.J.

    2010-01-01

    BACKGROUND: Anatomically shaped cohesive silicone breast implants are frequently used in aesthetic and reconstructive surgery. After successful results with the Style 410 prosthesis, McGhan (Natrelle, Allergan) introduced the Style 510 prosthesis. After using this novel prosthesis, the authors

  19. Finger prosthesis: a boon to handicapped.

    Science.gov (United States)

    Gupta, Ridhima; Kumar, Lakshya; Rao, Jitendra; Singh, Kamleshwar

    2013-08-29

    This is a clinical case report of a 52-year-old male patient with four partially missing fingers of the left hand. The article describes the clinical and laboratory procedure of making prosthesis with modern silicone material. A wax pattern was fabricated using the right hand of the patient. A special type of wax was formulated to make the pattern so that it can be easily moulded and carved. Intrinsic and extrinsic staining was also performed to match the adjacent skin colour. The patient was given the finger prosthesis and was asked to use a half glove (sports) to mask the junction between the prosthesis and the normal tissue. It also provides additional retention to the artificial fingers. The patient felt his social acceptance improved after wearing the finger prosthesis.

  20. The Effect of Lumbar Lordosis on Screw Loosening in Dynesys Dynamic Stabilization: Four-Year Follow-Up with Computed Tomography

    Directory of Open Access Journals (Sweden)

    Chao-Hung Kuo

    2015-01-01

    Full Text Available Introduction. This study aimed to evaluate the effects of Dynesys dynamic stabilization (DDS on clinical and radiographic outcomes, including spinal pelvic alignment. Method. Consecutive patients who underwent 1- or 2-level DDS for lumbar spondylosis, mild degenerative spondylolisthesis, or degenerative disc disease were included. Clinical outcomes were evaluated by Visual Analogue Scale for back and leg pain, Oswestry Disability Index, and the Japanese Orthopedic Association scores. Radiographic outcomes were assessed by radiographs and computed tomography. Pelvic incidence and lumbar lordosis (LL were also compared. Results. In 206 patients with an average follow-up of 51.1 ± 20.8 months, there were 87 screws (8.2% in 42 patients (20.4% that were loose. All clinical outcomes improved at each time point after operation. Patients with loosened screws were 45 years older. Furthermore, there was a higher risk of screw loosening in DDS involving S1, and these patients were more likely to have loosened screws if the LL failed to increase after the operation. Conclusions. The DDS screw loosening rate was overall 8.2% per screw and 20.4% per patient at more than 4 years of follow-up. Older patients, S1 involvement, and those patients who failed to gain LL postoperatively were at higher risk of screw loosening.

  1. Short-term results of the reverse Total Evolutive Shoulder System (TESS) in cuff tear arthropathy and revision arthroplasty cases.

    Science.gov (United States)

    von Engelhardt, Lars Victor; Manzke, Michael; Filler, Timm J; Jerosch, Joerg

    2015-07-01

    The aim of this study was to evaluate the clinical and radiological outcome of the Total Evolutive Shoulder System (TESS) in patients with cuff tear arthropathy and patients in need of a revision arthroplasty. In this sequential study, 67 patients (56 non-stemmed, 11 stemmed) were evaluated after a mean follow-up of 17.5 months. The relative Constant and DASH scores, radiological joint geometry changes, complications and postoperative problems, which are not likely to affect the outcome, were evaluated. A significant increase was noticed for the relative Constant (11.3 vs. 78.8 %) and DASH scores (73.7 vs. 31.8) without significant differences between both etiology groups. Complication rates were similar to previous studies. An aseptic loosening of the non-stemmed humeral component was not noticed in the cuff tear arthropathy group, whereas one case with a loosening was noticed in the revision arthroplasty group. With nine cases (13.4 %), scapular notching rates were very low. On average, the acromiohumeral distance increased by 17 mm and the humeral offset by 13.9 mm; the height of the center of rotation decreased by 4.6 mm and the lateral glenohumeral offset by 6.1 mm, p TESS system provided adequate distalization and medialization of the humerus and the center of rotation. This corresponds to a good clinical outcome. The use of the surgical opportunity to implant the prosthesis with a relatively low neck-shaft angle might explain the low rates of scapular notching in our series. Regarding the case with a loosening of the humeral component, the surgeon should carefully indicate a stemless version for metaphyseal press-fit fixation in patients with revision arthroplasty.

  2. Femoral loosening of high-flexion total knee arthroplasty: The effect of posterior cruciate ligament retention and bone quality reduction

    NARCIS (Netherlands)

    Zelle, J.; van de Groes, S.A.W.; De Waal Malefijt, M.C.; Verdonschot, Nicolaas Jacobus Joseph

    2014-01-01

    High-flexion total knee arthroplasty (TKA) may be more sensitive to femoral loosening than conventional TKA as the knee joint force increases during deep flexion. The objective of this study was to evaluate whether the probability of femoral loosening is equal in posterior cruciate ligament (PCL)

  3. Radiological and scintigraphic evaluation of hip prostheses

    International Nuclear Information System (INIS)

    Bessler, W.; Schaub, W.

    1979-01-01

    The radiological findings following the introduction of hip prostheses are often equivocal. Additional bone scintigrams often provide important information for the evaluation of the prostheses. 1. An unstable hip prosthesis is characterised by abnormal uptake in bone, due to static and mechanical stress. 2. A positive scintigram does not necessarily indicate instability of the prosthesis. Increased uptake may also be due to inflammatory bone changes, healing, bone replacement, abnormal local stresses or soft tissue calcification. 3. In evaluating the scintigram one must take account not only of the intensity of isotope uptake, but also its distribution and exact localisation. 4. It is essential to compare the scintigram with the radiograph. Radiological features of possible instability become diagnostic if they correspond with appropriate increased radioactivity. If the latter is absent, the of instability remains doubtful. 5. In some cases early loosening of the stem of the prosthesis can be diagnosed while the radiograph is still negative. Increased radioactivity in the acetabulum is frequently seen in the presence of a stable acetabular prosthesis and must be interpreted with caution as a sign of loosening of the prosthesis. (orig.) [de

  4. 21 CFR 878.3800 - External aesthetic restoration prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false External aesthetic restoration prosthesis. 878... External aesthetic restoration prosthesis. (a) Identification. An external aesthetic restoration prosthesis... (general controls). The device is exempt from the premarket notification procedures in subpart E of part...

  5. Rehabilitation of a Patient with an Intra Oral Prosthesis and an Extra Oral Orbital Prosthesis Retained with Magnets

    OpenAIRE

    Pattanaik, Seema; Wadkar, Aarti P.

    2011-01-01

    This clinical case report deals with a rehabilitation of a patient with an extensive maxillary and orbital defect using an intra oral prosthesis obturating the maxillary defect and extra oral orbital prosthesis retained with rare-earth magnets for secondary retention; primary retention was derived by snug fit of the prosthesis to underlying and adjacent tissues. The rehabilitation resulted in improved function, esthetics and comfort to the patient thus enabling him to lead a normal life.

  6. Can finite element models detect clinically inferior cemented hip implants?

    NARCIS (Netherlands)

    Stolk, J.; Maher, S.A.; Verdonschot, N.J.J.; Prendergast, P.J.; Huiskes, R.

    2003-01-01

    Rigorous preclinical testing of cemented hip prostheses against the damage accumulation failure scenario will reduce the incidence of aseptic loosening. For that purpose, a finite element simulation is proposed that predicts damage accumulation in the cement mantle and prosthetic migration. If the

  7. Attachment-retained gingival prosthesis for implant-supported fixed dental prosthesis in the maxilla: a clinical report.

    Science.gov (United States)

    Aparecida de Mattias Sartori, Ivete; Uhlendorf, Yuri; Padovan, Luiz Eduardo Marques; Junior, Paulo Domingos Ribeiro; Melo, Ana Cláudia Moreira; Tiossi, Rodrigo

    2014-12-01

    The rehabilitation of edentulous maxillae is a complex procedure due to the involvement of esthetic and functional requirements. A trial maxillary denture can be used to identify the need for adequate upper lip support when replacing removable complete dentures by implant-fixed dental prostheses. This clinical report describes the outcome of the rehabilitation of an edentulous atrophic maxilla with unfavorable maxillomandibular relationship and deficient upper lip support. A trial denture was fabricated and used to diagnose the need for a prosthesis capable of restoring the upper lip support. The reduced upper lip support was also confirmed by a lateral cephalogram. The patient was rehabilitated by an implant-fixed dental prosthesis associated with an attachment-retained gingival prosthesis. The case presented shows that when loss of upper lip support is detected and the patient does not wish to undergo further surgical reconstruction procedure, the retention of a gingival prosthesis using a ball attachment is a satisfactory treatment option. © 2014 by the American College of Prosthodontists.

  8. Prosthesis infections after orthopedic joint replacement

    DEFF Research Database (Denmark)

    Song, Zhijun; Borgwardt, Lotte; Høiby, Niels

    2013-01-01

    Prosthesis-related infection is a serious complication for patients after orthopedic joint replacement, which is currently difficult to treat with antibiotic therapy. Consequently, in most cases, removal of the infected prosthesis is the only solution to cure the infection. It is, therefore...

  9. Aseptic meningitis in Germany associated with echovirus type 13

    Directory of Open Access Journals (Sweden)

    Schreier Eckart

    2001-09-01

    Full Text Available Abstract Background Echoviruses are the commonest cause of aseptic meningitis. Echovirus type 13 which has not been isolated in Germany over a long period of time was the predominant enterovirus serotype associated with different local outbreaks of aseptic meningitis in Germany in 2000. Methods Virus isolation was performed from cerebrospinal fluid and stools. In order to study the genetic relationship of echovirus type 13 isolates, sequence analysis of a part of VP1 (~300 nt was carried out. Isolates from different geographic regions were compared to each other as well as to elder viruses (prototype strain from 1953, four isolates from 1965–1986. Results Overall, 55 isolates of echovirus type 13 were obtained from different parts of Germany. It was shown that the new isolated strains have a very high degree of homology on the nucleotide level (> 98% but differ significantly from the old strains (76–85%. Conclusions a Rare enterovirus serotypes can cause serious illness. b The molecular drift has also been shown for other enterovirus serotypes.

  10. Detection of periprosthetic joint infections in presumed aseptic patients

    DEFF Research Database (Denmark)

    Xu, Yijuan; Lorenzen, Jan; Thomsen, Trine Rolighed

    2016-01-01

    Title: Detection of periprosthetic joint infections in presumed aseptic patients Yijuan Xu1, Jan Lorenzen1, Trine Rolighed Thomsen1,2, Kathrin Kluba3, Kathrin Chamaon3, Christoph Lohmann3 1. Danish Technological Institute, Aarhus, Denmark 2. Center for Microbial Communities, Department of Biotech......Title: Detection of periprosthetic joint infections in presumed aseptic patients Yijuan Xu1, Jan Lorenzen1, Trine Rolighed Thomsen1,2, Kathrin Kluba3, Kathrin Chamaon3, Christoph Lohmann3 1. Danish Technological Institute, Aarhus, Denmark 2. Center for Microbial Communities, Department...... of Biotechnology, Chemistry and Environmental Engineering, Aalborg University, Denmark 3. Department of Orthopaedics, Otto-von-Guericke University of Magdeburg, Germany Aim: ”The HypOrth project (New approaches in the development of Hypoallergenic implant material in Orthopaedics: Steps to personalised medicine......) aims to investigate adverse immune reactions to implant materials. For this project, it is of utmost importance to exclude patients with periprosthetic joint infections (PJIs). The aim of this study was to rule out PJIs in included patients using prolonged culture and next generation sequencing (NGS...

  11. Life Estimation of Hip Joint Prosthesis

    Science.gov (United States)

    Desai, C.; Hirani, H.; Chawla, A.

    2015-07-01

    Hip joint is one of the largest weight-bearing structures in the human body. In the event of a failure of the natural hip joint, it is replaced with an artificial hip joint, known as hip joint prosthesis. The design of hip joint prosthesis must be such so as to resist fatigue failure of hip joint stem as well as bone cement, and minimize wear caused by sliding present between its head and socket. In the present paper an attempt is made to consider both fatigue and wear effects simultaneously in estimating functional-life of the hip joint prosthesis. The finite element modeling of hip joint prosthesis using HyperMesh™ (version 9) has been reported. The static analysis (load due to the dead weight of the body) and dynamic analysis (load due to walking cycle) have been described. Fatigue life is estimated by using the S-N curve of individual materials. To account for progressive wear of hip joint prosthesis, Archard's wear law, modifications in socket geometry and dynamic analysis have been used in a sequential manner. Using such sequential programming reduction in peak stress has been observed with increase in wear. Finally life is estimated on the basis of socket wear.

  12. Mesenteric Lymphadenopathy in Childhood Epidemic Aseptic Meningitis: Sonographic Features and Clinical Significance

    International Nuclear Information System (INIS)

    Mun, Sung Hee; Park, Young Chan; Lee, Young Hwan

    2006-01-01

    To evaluate the sonographic features of mesenteric lymphadenopathy in childhood epidemic aseptic meningitis and to assess their clinical significance. Thirty-three patients (25 male, 8 female: mean age, 8.6 years) with a diagnosis of aseptic meningitis were prospectively evaluated with abdominal ultrasonography for the presence of enlarged mesenteric nodes. The size and number of enlarged mesenteric lymph nodes were analyzed in relationship with the patient's age, between the patients with abdominal pain or diarrhea (16 cases, 48%) and asymptomatic patients (17 cases, 52%). Mesenteric lymphadenopathy was seen in 31 patients (94%), all 16 symptomatic and 15 of the 17 asymptomatic patients. The number of enlarged nodes was most prevalent between 6-10, seen in 16 patients (52%) and the largest node ranged in size from 4 to 8 mm. Among the 31 patients with mesenteric lymphadenopathy, the mean size of the largest node was statistically different between the symptomatic (6.0 mm) and asymptomatic (5.0 mm) groups (p = 0.021). The number of enlarged nodes and the patient's age were not statistically different between the two groups. Mesenteric lymphadenopathy was seen in almost all cases of childhood epidemic aseptic meningitis, and may be related to the mesenteric lymphadenitis caused by enterovirus

  13. Mesenteric Lymphadenopathy in Childhood Epidemic Aseptic Meningitis: Sonographic Features and Clinical Significance

    Energy Technology Data Exchange (ETDEWEB)

    Mun, Sung Hee; Park, Young Chan; Lee, Young Hwan [Catholic University of Daegu, College of Medicine, Daegu (Korea, Republic of)

    2006-09-15

    To evaluate the sonographic features of mesenteric lymphadenopathy in childhood epidemic aseptic meningitis and to assess their clinical significance. Thirty-three patients (25 male, 8 female: mean age, 8.6 years) with a diagnosis of aseptic meningitis were prospectively evaluated with abdominal ultrasonography for the presence of enlarged mesenteric nodes. The size and number of enlarged mesenteric lymph nodes were analyzed in relationship with the patient's age, between the patients with abdominal pain or diarrhea (16 cases, 48%) and asymptomatic patients (17 cases, 52%). Mesenteric lymphadenopathy was seen in 31 patients (94%), all 16 symptomatic and 15 of the 17 asymptomatic patients. The number of enlarged nodes was most prevalent between 6-10, seen in 16 patients (52%) and the largest node ranged in size from 4 to 8 mm. Among the 31 patients with mesenteric lymphadenopathy, the mean size of the largest node was statistically different between the symptomatic (6.0 mm) and asymptomatic (5.0 mm) groups (p = 0.021). The number of enlarged nodes and the patient's age were not statistically different between the two groups. Mesenteric lymphadenopathy was seen in almost all cases of childhood epidemic aseptic meningitis, and may be related to the mesenteric lymphadenitis caused by enterovirus

  14. 21 CFR 872.3950 - Glenoid fossa prosthesis.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3950 Glenoid fossa prosthesis. (a) Identification. A glenoid fossa prosthesis is a device that is intended to be implanted in the temporomandibular...

  15. White blood cell scintigraphy for differentiation of infection and aseptic loosening

    DEFF Research Database (Denmark)

    Simonsen, Lene; Buhl, Anna; Oersnes, Thue

    2007-01-01

    Diagnosis of an infected arthroplasty is often difficult. Fever, abnormal physical findings, radiographic changes, findings at bone scintigraphy, an elevated erythrocyte sedimentation rate, CRP, and leucocytosis are not specific enough. We evaluated the diagnostic value of white blood cell...

  16. Accuracy of bone SPECT/CT for identifying hardware loosening in patients who underwent lumbar fusion with pedicle screws

    Energy Technology Data Exchange (ETDEWEB)

    Hudyana, Hendrah; Maes, Alex [AZ Groeninge, Department of Nuclear Medicine, Kortrijk (Belgium); University Hospital Leuven, Department of Morphology and Medical Imaging, Leuven (Belgium); Vandenberghe, Thierry; Fidlers, Luc [AZ Groeninge, Department of Neurosurgery, Kortrijk (Belgium); Sathekge, Mike [University of Pretoria, Department of Nuclear Medicine, Pretoria (South Africa); Nicolai, Daniel [AZ Groeninge, Department of Nuclear Medicine, Kortrijk (Belgium); Wiele, Christophe van de [AZ Groeninge, Department of Nuclear Medicine, Kortrijk (Belgium); University Ghent, Department of Radiology and Nuclear Medicine, Ghent (Belgium)

    2016-02-15

    The aim of this retrospective study was to evaluate the accuracy of bone SPECT (single photon emission computed tomography)/CT (computed tomography) in diagnosing loosening of fixation material in patients with recurrent or persistent back pain that underwent lumbar arthrodesis with pedicle screws using surgery and clinical follow-up as gold standard A total of 48 patients (median age 49 years, range 21-81 years; 17 men) who had undergone lumbar spinal arthrodesis were included in this retrospective analysis. SPECT/CT results were compared to the gold standard of surgical evaluation or clinical follow-up. Positive SPECT/CT results were considered true positives if findings were confirmed by surgery or if clinical and other examinations were completely consistent with the positive SPECT/CT finding. They were considered false positives if surgical evaluation did not find any loose pedicle screws or if symptoms subsided with non-surgical therapy. Negative SPECT/CT scans were considered true negatives if symptoms either improved without surgical intervention or remained stable over a minimum follow-up period of 6 months. Negative SPECT/CT scans were determined to be false negatives if surgery was still required and loosening of material was found. The median length of time from primary surgery to bone SPECT/CT referral was 29.5 months (range 12-192 months). Median follow-up was 18 months (range 6-57) for subjects who did not undergo surgery. Thirteen of the 48 patients were found to be positive for loosening on bone SPECT/CT. Surgical evaluation (8 patients) and clinical follow-up (5 patients) showed that bone SPECT/CT correctly predicted loosening in 9 of 13 patients, while it falsely diagnosed loosening in 4 patients. Of 35 negative bone SPECT/CT scans, 12 were surgically confirmed. In 18 patients, bone SPECT/CT revealed lesions that could provide an alternative explanation for the symptoms of pain (active facet degeneration in 14 patients, and disc and sacroiliac

  17. Survey to explore understanding of the principles of aseptic technique: Qualitative content analysis with descriptive analysis of confidence and training.

    Science.gov (United States)

    Gould, Dinah J; Chudleigh, Jane; Purssell, Edward; Hawker, Clare; Gaze, Sarah; James, Deborah; Lynch, Mary; Pope, Nicola; Drey, Nicholas

    2018-04-01

    In many countries, aseptic procedures are undertaken by nurses in the general ward setting, but variation in practice has been reported, and evidence indicates that the principles underpinning aseptic technique are not well understood. A survey was conducted, employing a brief, purpose-designed, self-reported questionnaire. The response rate was 72%. Of those responding, 65% of nurses described aseptic technique in terms of the procedure used to undertake it, and 46% understood the principles of asepsis. The related concepts of cleanliness and sterilization were frequently confused with one another. Additionally, 72% reported that they not had received training for at least 5 years; 92% were confident of their ability to apply aseptic technique; and 90% reported that they had not been reassessed since their initial training. Qualitative analysis confirmed a lack of clarity about the meaning of aseptic technique. Nurses' understanding of aseptic technique and the concepts of sterility and cleanliness is inadequate, a finding in line with results of previous studies. This knowledge gap potentially places patients at risk. Nurses' understanding of the principles of asepsis could be improved. Further studies should establish the generalizability of the study findings. Possible improvements include renewed emphasis during initial nurse education, greater opportunity for updating knowledge and skills post-qualification, and audit of practice. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  18. Low Preoperative BMD Is Related to High Migration of Tibia Components in Uncemented TKA-92 Patients in a Combined DEXA and RSA Study With 2-Year Follow-Up

    DEFF Research Database (Denmark)

    Andersen, Mikkel R.; Winther, Nikkolaj S.; Lind, Thomas

    2017-01-01

    Background: The fixation of uncemented tibia components in total knee arthroplasty may rely on the bone quality of the tibia; however, no previous studies have shown convincing objective proof of this. Component migration is relevant as it has been shown to predict aseptic loosening. Methods: We ...

  19. Stretch due to Penile Prosthesis Reservoir Migration

    Directory of Open Access Journals (Sweden)

    E. Baten

    2016-03-01

    Full Text Available A 43-year old patient presented to the emergency department with stretch, due to impossible deflation of the penile prosthesis, 4 years after successful implant. A CT-scan showed migration of the reservoir to the left rectus abdominis muscle. Refilling of the reservoir was inhibited by muscular compression, causing stretch. Removal and replacement of the reservoir was performed, after which the prosthesis was well-functioning again. Migration of the penile prosthesis reservoir is extremely rare but can cause several complications, such as stretch.

  20. Rehabilitation of amputed thumb with a silicone prosthesis

    OpenAIRE

    Asnani, Pooja; Shivalingappa, Chandu Giriyapura; Mishra, Sunil Kumar; Somkuwar, Kirti; Khan, Faisal

    2015-01-01

    Creating prosthesis, having realistic skin surface and seamless visual integration with the surrounding tissues, requires both artistic and technical skill. Anatomical design, thin margins, lifelike fingernails and realistic color/contours are essential for patient satisfaction. Prosthesis is especially useful in case of lost body parts, as reconstructive surgery cannot fully restore aesthetics. This case report describes a simple technique for fabricating silicon finger prosthesis for a pati...

  1. Development and clinical application of a new testicular prosthesis.

    Science.gov (United States)

    Ning, Ye; Cai, Zhikang; Chen, Huixing; Ping, Ping; Li, Peng; Wang, Zhong; Li, Zheng

    2011-11-01

    A new type of testicular prosthesis made of silastic with an elliptical shape to mimic a normal testis was developed by our team and submitted for patenting in China. The prosthesis was produced in different sizes to imitate the normal testis of the patient. To investigate the effects and safety of the testicular prosthesis, 20 patients receiving testicular prosthesis implantation were recruited for this study. Follow-up after 6 months revealed no complications in the patients. All the patients answered that they were satisfied with their body image and the position of the implants, 19 patients were satisfied with the size and 16 patients were satisfied with the weight. These results show that the testicular prosthesis used in this study can meet patient's expectations. Patients undergoing orchiectomy should be offered the option to receive a testicular prosthesis implantation. The dimensions and weight of the available prosthetic implants should be further addressed to improve patient satisfaction.

  2. Different techniques in fabrication of ocular prosthesis.

    Science.gov (United States)

    Cevik, Pinar; Dilber, Erhan; Eraslan, Oguz

    2012-11-01

    Loss of an eye caused by cancer, trauma, or congenital defect creates a deep psychological impact on an individual's life especially social and professional life. Custom-made prosthesis, compared to stock prosthesis, provides a better fit to the eye socket, better cosmetic results, and less discomfort to the patient in the long term. The main objective of this article was to describe 3 different alternative and practical techniques of fabricating custom-made ocular prosthesis. An impression of anophthalmic socket was made with the addition of cured silicone-based precision impression material in all techniques. A master cast was prepared and duplicated with condensation silicone. A self-cure acrylic resin was polymerized in the silicone model and was fitted into the patient's eye socket. A digital photograph of the patient's iris was made using a digital camera and printed on good-quality photo paper in various shades and sizes in the first and the second techniques. Then the photo paper was coated with PVC so as not to allow any color flowing. The proper iris was then inserted to the acrylic base. The prosthesis was final processed using orthodontic heat polymerizing clear acrylic resin.In the other technique, after the trying-in process with wax pattern, an acrylic base was fabricated using heat polymerizing scleral acrylic resin. The prosthetic iris was fabricated from a transparent contact lens by painting the lens with watercolor paints and attaching it to an acrylic resin with tissue conditioner. The final process was made with heat polymerizing transparent acrylic resin. Custom-made prosthesis allows better esthetic and functional results to the patient in comparison to stock prosthesis. Further follow-up is necessary to check the condition and fit of the ocular prosthesis in such patients.

  3. Femoral Prosthesis Infection by Rhodotorula mucilaginosa▿

    Science.gov (United States)

    Savini, Vincenzo; Sozio, Federica; Catavitello, Chiara; Talia, Marzia; Manna, Assunta; Febbo, Fabio; Balbinot, Andrea; Di Bonaventura, Giovanni; Piccolomini, Raffaele; Parruti, Giustino; D'Antonio, Domenico

    2008-01-01

    This case report is a case history of a femoral prosthesis infection caused by Rhodotorula mucilaginosa in a human immunodeficiency virus patient. Though the pathogenicity of this organism for bone tissue has been previously reported, this is the first reported case of an orthopedic prosthesis infection by this species of the genus Rhodotorula. PMID:18753353

  4. Kinematic analysis of a posterior-stabilized knee prosthesis.

    Science.gov (United States)

    Zhao, Zhi-Xin; Wen, Liang; Qu, Tie-Bing; Hou, Li-Li; Xiang, Dong; Bin, Jia

    2015-01-20

    The goal of total knee arthroplasty (TKA) is to restore knee kinematics. Knee prosthesis design plays a very important role in successful restoration. Here, kinematics models of normal and prosthetic knees were created and validated using previously published data. Computed tomography and magnetic resonance imaging scans of a healthy, anticorrosive female cadaver were used to establish a model of the entire lower limbs, including the femur, tibia, patella, fibula, distal femur cartilage, and medial and lateral menisci, as well as the anterior cruciate, posterior cruciate, medial collateral, and lateral collateral ligaments. The data from the three-dimensional models of the normal knee joint and a posterior-stabilized (PS) knee prosthesis were imported into finite element analysis software to create the final kinematic model of the TKA prosthesis, which was then validated by comparison with a previous study. The displacement of the medial/lateral femur and the internal rotation angle of the tibia were analyzed during 0-135° flexion. Both the output data trends and the measured values derived from the normal knee's kinematics model were very close to the results reported in a previous in vivo study, suggesting that this model can be used for further analyses. The PS knee prosthesis underwent an abnormal forward displacement compared with the normal knee and has insufficient, or insufficiently aggressive, "rollback" compared with the lateral femur of the normal knee. In addition, a certain degree of reverse rotation occurs during flexion of the PS knee prosthesis. There were still several differences between the kinematics of the PS knee prosthesis and a normal knee, suggesting room for improving the design of the PS knee prosthesis. The abnormal kinematics during early flexion shows that the design of the articular surface played a vital role in improving the kinematics of the PS knee prosthesis.

  5. Kinematic Analysis of a Posterior-stabilized Knee Prosthesis

    Directory of Open Access Journals (Sweden)

    Zhi-Xin Zhao

    2015-01-01

    Full Text Available Background: The goal of total knee arthroplasty (TKA is to restore knee kinematics. Knee prosthesis design plays a very important role in successful restoration. Here, kinematics models of normal and prosthetic knees were created and validated using previously published data. Methods: Computed tomography and magnetic resonance imaging scans of a healthy, anticorrosive female cadaver were used to establish a model of the entire lower limbs, including the femur, tibia, patella, fibula, distal femur cartilage, and medial and lateral menisci, as well as the anterior cruciate, posterior cruciate, medial collateral, and lateral collateral ligaments. The data from the three-dimensional models of the normal knee joint and a posterior-stabilized (PS knee prosthesis were imported into finite element analysis software to create the final kinematic model of the TKA prosthesis, which was then validated by comparison with a previous study. The displacement of the medial/lateral femur and the internal rotation angle of the tibia were analyzed during 0-135° flexion. Results: Both the output data trends and the measured values derived from the normal knee′s kinematics model were very close to the results reported in a previous in vivo study, suggesting that this model can be used for further analyses. The PS knee prosthesis underwent an abnormal forward displacement compared with the normal knee and has insufficient, or insufficiently aggressive, "rollback" compared with the lateral femur of the normal knee. In addition, a certain degree of reverse rotation occurs during flexion of the PS knee prosthesis. Conclusions: There were still several differences between the kinematics of the PS knee prosthesis and a normal knee, suggesting room for improving the design of the PS knee prosthesis. The abnormal kinematics during early flexion shows that the design of the articular surface played a vital role in improving the kinematics of the PS knee prosthesis.

  6. Kinematic Analysis of a Posterior-stabilized Knee Prosthesis

    Science.gov (United States)

    Zhao, Zhi-Xin; Wen, Liang; Qu, Tie-Bing; Hou, Li-Li; Xiang, Dong; Bin, Jia

    2015-01-01

    Background: The goal of total knee arthroplasty (TKA) is to restore knee kinematics. Knee prosthesis design plays a very important role in successful restoration. Here, kinematics models of normal and prosthetic knees were created and validated using previously published data. Methods: Computed tomography and magnetic resonance imaging scans of a healthy, anticorrosive female cadaver were used to establish a model of the entire lower limbs, including the femur, tibia, patella, fibula, distal femur cartilage, and medial and lateral menisci, as well as the anterior cruciate, posterior cruciate, medial collateral, and lateral collateral ligaments. The data from the three-dimensional models of the normal knee joint and a posterior-stabilized (PS) knee prosthesis were imported into finite element analysis software to create the final kinematic model of the TKA prosthesis, which was then validated by comparison with a previous study. The displacement of the medial/lateral femur and the internal rotation angle of the tibia were analyzed during 0–135° flexion. Results: Both the output data trends and the measured values derived from the normal knee's kinematics model were very close to the results reported in a previous in vivo study, suggesting that this model can be used for further analyses. The PS knee prosthesis underwent an abnormal forward displacement compared with the normal knee and has insufficient, or insufficiently aggressive, “rollback” compared with the lateral femur of the normal knee. In addition, a certain degree of reverse rotation occurs during flexion of the PS knee prosthesis. Conclusions: There were still several differences between the kinematics of the PS knee prosthesis and a normal knee, suggesting room for improving the design of the PS knee prosthesis. The abnormal kinematics during early flexion shows that the design of the articular surface played a vital role in improving the kinematics of the PS knee prosthesis. PMID:25591565

  7. Prosthetic management of mid-facial defect with magnet-retained silicone prosthesis.

    Science.gov (United States)

    Buzayan, Muaiyed M

    2014-02-01

    Mid-facial defect is one of the most disfiguring and impairing defects. A design of prosthesis that is aesthetic and stable can be precious to a patient who has lost part of his face due to surgical excision. Prosthesis can restore the patients' self-esteem and confidence, which affects the patients and their life style. The aim of this case report is to describe a technique of mid-facial silicone prosthesis fabrication. To provide an aesthetic and stable facial prosthesis, the extra-oral prosthesis was fabricated using silicone material, while the intra-oral defect was restored with obturator prosthesis, and then both prostheses were connected and attached to each other using magnets. This clinical report describes the rehabilitation of a large mid-facial defect with a two-piece prosthesis. The silicone facial prosthesis was made hollow and lighter by using an acrylic framework. Two acrylic channels were included within the facial prosthesis to provide the patient with clean and patent airways. A sectional mid-facial prosthesis was made and retained in place by using magnets, which resulted in a significant improvement in the aesthetical and functional outcome without the need for plastic surgery. Silicone prostheses are reliable alternatives to surgery and should be considered in selected cases.

  8. Molecularly specific detection of bacterial lipoteichoic acid for diagnosis of prosthetic joint infection of the bone.

    Science.gov (United States)

    Pickett, Julie E; Thompson, John M; Sadowska, Agnieszka; Tkaczyk, Christine; Sellman, Bret R; Minola, Andrea; Corti, Davide; Lanzavecchia, Antonio; Miller, Lloyd S; Thorek, Daniel Lj

    2018-01-01

    Discriminating sterile inflammation from infection, especially in cases of aseptic loosening versus an actual prosthetic joint infection, is challenging and has significant treatment implications. Our goal was to evaluate a novel human monoclonal antibody (mAb) probe directed against the Gram-positive bacterial surface molecule lipoteichoic acid (LTA). Specificity and affinity were assessed in vitro. We then radiolabeled the anti-LTA mAb and evaluated its effectiveness as a diagnostic imaging tool for detecting infection via immunoPET imaging in an in vivo mouse model of prosthetic joint infection (PJI). In vitro and ex vivo binding of the anti-LTA mAb to pathogenic bacteria was measured with Octet, ELISA, and flow cytometry. The in vivo PJI mouse model was assessed using traditional imaging modalities, including positron emission tomography (PET) with [ 18 F]FDG and [ 18 F]NaF as well as X-ray computed tomography (CT), before being evaluated with the zirconium-89-labeled antibody specific for LTA ([ 89 Zr]SAC55). The anti-LTA mAb exhibited specific binding in vitro to LTA-expressing bacteria. Results from imaging showed that our model could reliably simulate infection at the surgical site by bioluminescent imaging, conventional PET tracer imaging, and bone morphological changes by CT. One day following injection of both the radiolabeled anti-LTA and isotype control antibodies, the anti-LTA antibody demonstrated significantly greater ( P  infected prosthesis sites over either the same antibody at sterile prosthesis sites or of control non-specific antibody at infected prosthesis sites. Taken together, the radiolabeled anti-LTA mAb, [ 89 Zr]SAC55, may serve as a valuable diagnostic molecular imaging probe to help distinguish between sterile inflammation and infection in the setting of PJI. Future studies are needed to determine whether these findings will translate to human PJI.

  9. Body image and prosthesis satisfaction in the lower limb amputee.

    OpenAIRE

    Murray, Craig; Fox, Jezz

    2002-01-01

    Purpose: This study examines the relationship between prosthesis satisfaction and body image in lower limb prosthesis users, and the gendered variations within these relationships. Method: A total of 44 valid responses were obtained to an Internet survey regarding prosthesis satisfaction, body image, and phantom pain. Spearman Rho correlations were calculated for these three domains. Results: Moderate to high negative correlations were observed between Body Image Disturbance and Prosthesis Sa...

  10. Dual infection with hepatitis A and E virus presenting with aseptic meningitis: a case report.

    Science.gov (United States)

    Naha, Kushal; Karanth, Suman; Prabhu, Mukhyaprana; Sidhu, Manpreet Singh

    2012-07-01

    We report the case of a young male who presented with features of aseptic meningitis and elevated serum liver enzymes, but no symptoms or signs suggestive of an acute hepatitis. Subsequently, he was diagnosed with dual infection with hepatitis A and E viruses, and recovered completely with symptomatic therapy. Isolated aseptic meningitis, unaccompanied by hepatitic features is an unusual presentation of a hepatotrophic viral infection, and is yet to be reported with hepatitis A and E virus co-infection. Copyright © 2012 Hainan Medical College. Published by Elsevier B.V. All rights reserved.

  11. Self-contained inflatable penile prosthesis: magnetic resonance appearance

    International Nuclear Information System (INIS)

    Levin, M.F.; Munk, P.L.; Vellet, A.D.; Chin, J.L.

    1994-01-01

    The appearance of an inflatable penile prosthesis, visualized on a short tau inversion recovery sequence, is reported, in a patient who had magnetic resonance imaging for pelvic pain subsequent to radical cystoprostatectomy for bladder carcinoma. With suppression of adjacent fat signal, the prosthesis is well delineated from adjacent structures. The fluid-containing cylinders of the prosthesis are of very bright signal intensity, with the relief valve assembly of low signal intensity. 5 refs., 2 figs

  12. Fabrication of temporary speech bulb prosthesis: A clinical report

    OpenAIRE

    Kasim Mohamed, K.; Anand Kumar, V.; Devi, N.; Padmanaban, T. V.

    2010-01-01

    Maxillofacial prosthesis is an art and science which not only replaces the lost structure sometimes it restores the functions also. Pharyngeal obturator is a prosthesis which closes the palatal and pharyngeal defects and improving the speech and other function. The following case report discusses palatopharyngeal insufficiency, impression procedures, fabrication of prosthesis and improvements in speech.

  13. Closed-eye orbital prosthesis: a clinical report.

    Science.gov (United States)

    Hatamleh, Muhanad M; Watson, Jason; Srinivasan, Dilip

    2015-03-01

    One of the most challenging prostheses to fabricate is an acceptable orbital prosthesis. Successful reconstruction of the complex missing tissues, the globe, muscle, skin, and bony elements requires time and high levels of practical skill. A good match to the contralateral nondefect side will help mask the underlying defect and give the patient confidence to return to normal, routine life. The contralateral eye opening will commonly dictate the eye opening of such a prosthesis, but because of the expressive nature of the eye and its high levels of mobility, this can be difficult to achieve. This clinical report presents a patient who had an extended orbital exenteration and right maxillectomy to remove a maxillary squamous cell carcinoma. An alternative approach to constructing an orbital prosthesis was undertaken with the eye closed. Compared to the normal method of fabrication, this process was less complex and quicker, made the prosthesis less "staring," camouflaged the defect, and reduced the detection of the prosthesis because of movements in the remaining eye. The patient engaged in his routine daily life, which reinforced his self-esteem, confidence, and reintegration into the community. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  14. Total knee replacement with retention of both cruciate ligaments: a 22-year follow-up study.

    Science.gov (United States)

    Sabouret, P; Lavoie, F; Cloutier, J-M

    2013-07-01

    We report on the long-term results of 163 bicruciate-retaining Hermes 2C total knee replacements in 130 patients at a mean follow-up of 22.4 years (20.3 to 23.5). Even when the anterior cruciate ligament had a partially degenerative appearance it was preserved as long as the knee had a normal anterior drawer and Lachman's test pre-operatively. The description and surgical technique of this minimally constrained prosthesis were published in 1983 and the ten-year clinical results in 1999. A total of 12% of the knees (20 of 163) in this study were revised because of wear of the polyethylene tibial insert. Excellent stability was achieved and the incidence of aseptic component loosening was 4.3% (seven of 163). The survival rate using revision for any reason as the endpoint was 82% (95% confidence interval 76.2 to 88.0). Although this series included a relatively small number of replacements, it demonstrated that the anterior cruciate ligament, even when partially degenerated at the time of TKR, remained functional and provided adequate stability at a long-term follow-up.

  15. Validation of the aseptic filling at the Parenteral Products Plant 3 in BioCen

    Directory of Open Access Journals (Sweden)

    Marisol Álvarez-González

    2016-07-01

    Full Text Available As part of the continuous improvement process, a new parenterals production plant (PPP3 was constructed at the National Center for Bioproducts. The validation of the aseptic filling process is a key element to carry out before manufacturing products. Therefore, the aim of this work was to obtain documented evidence that all the operations were carried out according the regulations of Good Manufacturing Practices for liquid and lyophilized sterile products during the aseptic filling at the Parenterals Product Plant 3. The study was designed for lyophilized products connected to the manifold of the peristaltic pump and to the four rotary piston pumps. Besides, during the filling operation four interventions were planned. The validation was carried out with three consecutive batches of media fill. In the first processed lot no vial was contaminated, but in the second and third lots there was one contaminated vial. For that reason, an investigation was performed in order to know the cause of the contamination. Finally, with this wok the validated condition was obtained, following the regulations of Good Manufacturing Practices for sterile liquids and lyophilizes products during the aseptic filling process at the Parenterals Products Plant 3.

  16. Clinical Outcomes of Penile Prosthesis Implantation Surgery

    Directory of Open Access Journals (Sweden)

    Onur Dede

    2016-06-01

    Full Text Available Objective: We aimed to evaluating the outcomes of in­flatable penile prosthesis implantations and partner sat­isfaction. Methods: Data of 52 patients who underwent penile prosthesis implantation in single center between May 2010 and December 2015 were retrospectively analyzed. Types of prosthesis, complication and satisfaction rates of patients were recorded by EDITS (Erectile Dysfunction Inventory of Treatment Satisfaction questionnaire was used. Results: The mean age was 49.2±14.7 years for patients. The mean follow-up durations for 34.3±12.5 months. The mean hospital stay was 3.84±1.52 days. Evaluating of the couples satisfaction revealed that 44 (84% of the patient were very satisfied. There was not any complication and no patient need to underwent revision surgery. Conclusion: Inflatable penile prosthesis implants, with high levels of treatment success, patient and partner sat­isfaction, are effective and safe options for treatment of organic erectile dysfunction with acceptable complication and revision rates.

  17. Outcomes of dual mobility components in total hip arthroplasty: a systematic review of the literature.

    Science.gov (United States)

    Darrith, B; Courtney, P M; Della Valle, C J

    2018-01-01

    Instability remains a challenging problem in both primary and revision total hip arthroplasty (THA). Dual mobility components confer increased stability, but there are concerns about the unique complications associated with these designs, as well as the long-term survivorship. We performed a systematic review of all English language articles dealing with dual mobility THAs published between 2007 and 2016 in the MEDLINE and Embase electronic databases. A total of 54 articles met inclusion criteria for the final analysis of primary and revision dual mobility THAs and dual mobility THAs used in the treatment of fractures of the femoral neck. We analysed the survivorship and rates of aseptic loosening and of intraprosthetic and extra-articular dislocation. For the 10 783 primary dual mobility THAs, the incidence of aseptic loosening was 1.3% (142 hips); the rate of intraprosthetic dislocation was 1.1% (122 hips) and the incidence of extra-articular dislocation was 0.46% (41 hips). The overall survivorship of the acetabular component and the dual mobility components was 98.0%, with all-cause revision as the endpoint at a mean follow-up of 8.5 years (2 to 16.5). For the 3008 revision dual mobility THAs, the rate of aseptic acetabular loosening was 1.4% (29 hips); the rate of intraprosthetic dislocation was 0.3% (eight hips) and the rate of extra-articular dislocation was 2.2% (67 hips). The survivorship of the acatabular and dual mobility components was 96.6% at a mean of 5.4 years (2 to 8). For the 554 dual mobility THAs which were undertaken in patients with a fracture of the femoral neck, the rate of intraprosthetic dislocation was 0.18% (one hip), the rate of extra-articular dislocation was 2.3% (13 hips) and there was one aseptic loosening. The survivorship was 97.8% at a mean of 1.3 years (0.75 to 2). Dual mobility articulations are a viable alternative to traditional bearing surfaces, with low rates of instability and good overall survivorship in primary and

  18. Hearing results using the SMart piston prosthesis.

    Science.gov (United States)

    Fayad, Jose N; Semaan, Maroun T; Meier, Josh C; House, John W

    2009-12-01

    SMart, a newly introduced piston prosthesis for stapedotomy, is a nitinol-based, heat-activated, self-crimping prosthesis. We review our hearing results and postoperative complications using this self-crimped piston prosthesis and compare them with those obtained using stainless steel or platinum piston prostheses. Audiometric results using the SMart piston are identical to those obtained using a conventional piston prosthesis. Retrospective chart review. Private neurotologic tertiary referral center. The 416 ears reviewed included 306 with a SMart prosthesis and 110 conventional prostheses. 61% were women. Mean follow-up time was 5.6 (standard deviation [SD], 6.3 mo) and 6.9 months (SD, 7.0 mo) for the 2 groups, respectively. Stapedotomy using the SMart or a conventional (non-SMart) prosthesis. Audiometric hearing results, including pure-tone average (PTA) and air-bone gap (ABG), and prevalence of postoperative complications. Mean postoperative PTA was 32.6 (SD, 16.8) dB for the SMart group and 29.4 (SD, 13.5) dB for the non-SMart group, with ABGs of 7.6 (SD, 8.9) and 6.0 (SD, 5.2) dB, respectively. Mean change (decrease) in ABG was 18.7 (SD, 13.1) dB for the SMart group and 19.9 (SD, 10.3) dB for the non-SMart group. High-frequency bone PTAs showed overclosure of 2.0 (SD, 7.9) dB for the SMart group and 3.6 (SD, 8.6) dB for the non-SMart group. Postoperative vertigo and tinnitus were infrequent. No significant differences in these audiometric outcomes or complication rates were noted between groups. There was no significant difference in rate of gap closure to within 10 dB (78.3 versus 84.2%, SMart and non-SMart, respectively) or 20 dB (94.2 and 98.0%). Compared with conventional stapes prostheses, the nitinol-based SMart is a safe and reliable stapes prosthesis that eliminates manual crimping without significantly altering the audiometric outcome. Complications are rare, but longer follow-up is needed before establishing long-term stability.

  19. Difficult factors in Management of Impacted Dental Prosthesis in Esophagus

    Directory of Open Access Journals (Sweden)

    Efiaty A. Soepardi

    2005-03-01

    Full Text Available A dental prosthesis which ingested and impacted in esophagus, is an emergency case and life threatening, so require immediate esophagoscopy intervention for removing. The objective of this study is to assess some factors can caused dtfficulties in diagnosing and treating the ingested and impacted dental prosthesis in the esophagus and their complications. This retrospective study analyzed patient’s chart whose underwent esophagoscopy for removing the impacted dental prosthesis in Dr. Cipto Mangunkusumo General Hospital, Jakarta, Indonesia during a period between January 1997 and December 2003. Neck-chest X-ray and esophagoscopy were performed in all patients to identify the existence of the dental prosthesis as a diagnostic and treatment procedure. The length of time for removing the dental prosthesis was recorded and stated as a less difficult esophagoscopy when it takes time less than 60 minutes and as a difficult  esophagoscopy takes 60 minutes or longer. Some risk difficulties factors were statistically analyzed. There were 53 patients of ingested dental prosthesis in esophagus. Only 51 cases were analyzed According to the length of time for removing the dental prosthesis by esophagoscopy, 22 patients were recorded as less difficult cases and 29 patients as difficult cases. Two cases among the cases needed cervicotomy after unsuccessful esophagoscopy removal. The difficulties to diagnose an impacted dental prosthesis in the esophagus caused by unreliable clinical history, unclear signs and symptoms, unable to be detected by X-ray and was not found during esophagoscopy. The difficulties in treating due to mucosal laceration, edema, bleeding, failure of the first extraction and conformity with the size and shape, the wire outside the dental prosthesis and the length of time stayed in the esophagus. (Med J Indones 2005; 14: 33-6Keywords: ingested dental prosthesis, radioluscent foreign body, length of time of esophagoscopy

  20. Increased risk of revision in patients with non-traumatic femoral head necrosis 11,589 cases compared to 416,217 cases with primary osteoarthritis in the NARA database, 1995–2011

    DEFF Research Database (Denmark)

    Bergh, C.; Fenstad, Ann M.; Furnes, O.

    2014-01-01

    . The relative risk of revision for any reason, for aseptic loosening, dislocation, deep infection, and periprosthetic fracture was studied before and after adjustment for covariates using Cox regression models. Results - 416,217 hips with POA (mean age 69 (SD 10), 59% females) and 11,589 with FHN (mean age 65...

  1. Measurements of Repeated Tightening and Loosening Torque of Seven Different Implant/Abutment Connection Designs and Their Modifications: An In Vitro Study.

    Science.gov (United States)

    Butkevica, Alena; Nathanson, Dan; Pober, Richard; Strating, Herman

    2018-02-01

    Repeated tightening and loosening of the abutment screw may alter its mechanical and physical properties affecting the optimal torque and ultimate reliability of an implant/abutment connection. The purpose of this study was to evaluate the effect of repeated tightening and loosening of implant/abutment screws on the loosening torque of implant/abutment connections of commercially available implant systems. Seven different implant/abutment connections and their modifications were tested. The screws of each system were tightened according to the manufacturer's specifications. After 20 minutes the screws were loosened. This procedure was repeated ten times, and the differences between the 1st and 10th cycle were expressed as a percentage change RTq(%) and correlated with initial torque, the number of threads, the length of shank, and thread surface area employing Spearman's analysis. All systems showed significant differences in residual torque (RTq) value (p 0.05). All connections but group 3 (p = 1.000) showed a significant change from the initial torque (ITq) to the RTq values. The first successive RTq values increased in two connection groups 1 and 2. The remaining connections showed reduced RTq values ranging from -1.2 % (group 5) to -23.5% (group 6). The RTq values declined gradually with every repeated tightening in groups 1, 2, 3, 8, 9, 11, 12. In group 2, after the tenth tightening the RTq was still above the ITq value. Only length of shank demonstrated a correlation with the RTq(%) change over the successive tightening loosening cycles (p abutment screws caused varying torque level changes among the different systems. These observations can probably be attributed to connection design. Limiting the number of tightening/loosening cycles in clinical and laboratory procedures is advisable for most of the implant systems tested. © 2016 by the American College of Prosthodontists.

  2. Impact of aortic prosthesis-patient mismatch on left ventricular mass regression.

    Science.gov (United States)

    Alassal, Mohamed A; Ibrahim, Bedir M; Elsadeck, Nabil

    2014-06-01

    Prostheses used for aortic valve replacement may be small in relation to body size, causing prosthesis-patient mismatch and delaying left ventricular mass regression. This study examined the effect of prosthesis-patient mismatch on regression of left ventricular mass after aortic valve replacement. We prospectively studied 96 patients undergoing aortic valve replacement between 2007 and 2012. Mean and peak gradients and indexed effective orifice area were measured by transthoracic echocardiography at 3 and 6 months postoperatively. Patient-prosthesis mismatch was defined as indexed effective orifice area ≤0.85 cm(2)·m(-2). Moderate prosthesis-patient mismatch was present in 25% of patients. There were no significant differences in demographic and operative data between patients with and without prosthesis-patient mismatch. Left ventricular dimensions, posterior wall thickness, transvalvular gradients, and left ventricular mass decreased significantly after aortic valve replacement in both groups. The interventricular septal diameter and left ventricular mass index regression, and left ventricular ejection fraction were better in patients without prosthesis-patient mismatch. There was a significant positive correlation between the postoperative indexed effective orifice area of each valve prosthesis and the rate of left ventricular mass regression. Prosthesis-patient mismatch leads to higher transprosthetic gradients and impaired left ventricular mass regression. A small-sized valve prosthesis does not necessarily result in prosthesis-patient mismatch, and may be perfectly adequate in patient with small body size. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  3. [The endo-exo prosthesis for patients with a problematic amputation stump].

    Science.gov (United States)

    Frölke, Jan Paul M; van de Meent, Henk

    2010-01-01

    Following lower limb amputation, quality of life is highly related to the ability to use a prosthetic limb. The conventional way to attach a prosthetic limb to the body is with a socket. Many patients experience serious discomfort wearing a conventional prosthesis because of pain, instability during walking, pressure sores, bad smell or skin irritation. In addition, sitting is uncomfortable and pelvic and lower back pain due to unstable gait is often seen in these patients. The main disadvantage of the current prosthesis is the attachment of a rigid prosthesis socket to a soft and variable body. The socket must fit tightly for stability during walking but should also be comfortable for sitting. The implantation of an osseointegrated, intramedullary, transcutaneously conducted prosthesis is a new procedure for attaching a limb prosthesis to the human body without the disadvantages of the conventional prosthesis. The intramedullary prosthesis is designed with a rough surface resembling cancellous bone to enable a secure solid integration with the long bone. We treated two patients with this new prosthesis, a 44-year-old man after a transfemoral amputation, and a 32-year-old woman after a lower leg amputation; both amputations were necessary because of trauma. Those two patients are now, more than one year after the operation, showing excellent functional results without infectious complications. We assume that endo-exo prosthesis may be a promising option for selected patients unable to use a conventional prosthesis because of a problematic amputation stump.

  4. 5-year clinical and radiostereometric analysis (RSA) follow-up of 39 CUT femoral neck total hip prostheses in young osteoarthritis patients

    Science.gov (United States)

    2012-01-01

    Background As the number of young patients receiving total hip arthroplasty increases, bone-saving implantations facilitating possible future revision, such as the CUT femoral neck prosthesis, are gaining importance. There have been few medium-term results reported for this prosthesis, however, and its migration pattern has not been analyzed. Patients and methods 39 consecutive CUT femoral neck prostheses were implanted in 32 patients, mean age 37 (17–58) years, with symptomatic osteoarthritis and either less than 55 years of age or with an anatomic anomaly preventing implantation of a diaphyseal stem (n = 1). Patients were followed prospectively using routine clinical examination and radiostereometric analysis (RSA) at 6, 12, 26, and 52 weeks postoperatively and annually thereafter. This study evaluated the 5-year follow-up results. Results The mean Harris hip score increased from 26 (3–51) points preoperatively to 84 (66–98), 86 (55–98), and 87 (47–98) points at 3, 12, and 60 months. 3 stems were revised: 1 after luxation following excessive subsidence due to an undersized component and 2 due to persistent strong thigh pain. 5-year survival was 95% (95% CI: 87–100). Initial migration varied widely in magnitude; median total tip migration was 0.42 mm (0.09–9.4) at 6 weeks, 0.92 mm (0.18–5.9) at 1 year, and 1.10 mm (0.13–6.4) at 5 years. Even after high initial migration, stabilization was achieved in 31 of the 35 RSA-evaluable implants. 3 prostheses showed progressive continuous migration throughout the entire follow-up period, and were considered to be loose, suggesting reduced long-term survival. Interpretation Currently, we cannot recommend the CUT femoral neck prosthesis as a routine treatment option in (young) patients requiring THA. The CUT prosthesis may not reach the 90% survival benchmark at 10 years, and the prosthesis is difficult to implant. If initial stabilization is achieved, however, aseptic loosening is unlikely. A good clinical

  5. Clinical predictors of prosthesis-patient mismatch after aortic valve replacement for aortic stenosis

    Directory of Open Access Journals (Sweden)

    Luis M Astudillo

    2012-01-01

    Full Text Available OBJECTIVE: We sought to ascertain predictors of Patient Prosthesis Mismatch, an independent predictor of mortality, in patients with aortic stenosis using bioprosthetic valves. METHOD: We analyzed 2,107 sequential surgeries. Patient Prosthesis Mismatch was calculated using the effective orifice area of the prosthesis divided by the patient's body surface area. We defined nonsignificant, moderate, and severe Patient Prosthesis Mismatch as effective orifice area indexes of .0.85 cm²/m, 0.85-0.66 cm²/m², and <0.65 cm²/m², respectively. RESULTS: A total of 311 bioprosthetic patients were identified. The incidence of nonsignificant, moderate, and severe Patient Prosthesis Mismatch was 41%, 42, and 16%, respectively. Severe Patient Prosthesis Mismatch was significantly more prevalent in females (82%. In severe Patient Prosthesis Mismatch, the perfusion and the crossclamp times were considerably lower when compared with nonsignificant Patient Prosthesis Mismatch and moderate Patient Prosthesis Mismatch. Patients with severe Patient Prosthesis Mismatch had a significantly higher likelihood of spending time in the intensive care unit and a significantly longer length of stay in the hospital. Body surface area was not different in severe Patient Prosthesis Mismatch when compared with nonsignificant Patient Prosthesis Mismatch. In-hospital mortality in patients with nonsignificant, moderate, and severe Patient Prosthesis Mismatch was 2.3%, 6.1%, and 8%, respectively. Minimally invasive surgery was significantly associated with moderate Patient Prosthesis Mismatch in 49% of the patients, but not with severe Patient Prosthesis Mismatch. CONCLUSION: Severe Patient Prosthesis Mismatch is more common in females, but not in those with minimal available body surface area. Though operative times were shorter in these patients, intensive care unit and hospital lengths of stay were longer. Surgeons and cardiologists should be cognizant of these clinical

  6. A diagnostic dilemma: drug-induced aseptic meningitis in a 45-year-old HIV-positive man.

    LENUS (Irish Health Repository)

    Rowley, D

    2014-03-01

    We describe a case of aseptic meningitis following the administration of moxifloxacin in a 45-year-old man with human immunodeficiency virus (HIV). At presentation he was receiving tuberculosis treatment on a modified regimen following severe hepatotoxicity; this included moxifloxacin, started 8 days previously. Initial cerebrospinal fluid (CSF) analysis was grossly abnormal. Anti-viral and -bacterial treatments were started. All microbiological tests proved negative and his moxifloxacin was withheld resulting in a complete normalisation of CSF. Drug-induced aseptic meningitis is a diagnosis of exclusion and presents a serious diagnostic dilemma. The decision to withhold medication cannot be taken lightly.

  7. Intermittent, noncyclic dysfunction of a mechanical aortic prosthesis by pannus formation.

    Science.gov (United States)

    Giroux, Sylvie K; Labinaz, Marino X; Grisoli, Dominique; Klug, Andrew P; Veinot, John P; Burwash, Ian G

    2010-01-01

    Mechanical aortic prosthesis dysfunction can result from thrombosis or pannus formation. Pannus formation usually restricts systolic excursion of the occluding disk, resulting in progressive stenosis of the aortic prosthesis. Intermittent dysfunction of a mechanical aortic prosthesis is usually ascribed to thrombus formation. We describe an unusual case of intermittent, noncyclic dysfunction of a mechanical aortic prosthesis due to pannus formation in the absence of systolic restriction of disk excursion that presented with intermittent massive aortic regurgitation, severe ischemia, and shock. Pannus formation should be considered as a potential cause of acute intermittent severe aortic regurgitation in a patient with a mechanical aortic prosthesis.

  8. 21 CFR 888.3760 - Wrist joint carpal scaphoid polymer prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal scaphoid polymer prosthesis. 888.3760 Section 888.3760 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... scaphoid polymer prosthesis. (a) Identification. A wrist joint carpal scaphoid polymer prosthesis is a one...

  9. 21 CFR 888.3750 - Wrist joint carpal lunate polymer prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal lunate polymer prosthesis. 888.3750 Section 888.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... lunate polymer prosthesis. (a) Identification. A wrist joint carpal lunate prosthesis is a one-piece...

  10. 21 CFR 888.3770 - Wrist joint carpal trapezium polymer prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal trapezium polymer prosthesis. 888.3770 Section 888.3770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... trapezium polymer prosthesis. (a) Identification. A wrist joint carpal trapezium polymer prosthesis is a one...

  11. A modified technique for retention of orbital prosthesis

    Directory of Open Access Journals (Sweden)

    Sameera R Shaikh

    2011-01-01

    Full Text Available An orbital defect (congenital or acquired causes severe facial asymmetry and disfigurement, which results in psychological and social disturbances to the patient. It becomes a challenging task for a maxillofacial prosthodontist to fabricate a prosthesis that replicates the healthy side of the face. Success of the prosthesis depends primarily on satisfactory retention of the same. This clinical report illustrates rehabilitation of a patient with an orbital defect by fabricating a hollow orbital prosthesis, utilizing anatomical undercuts for retention using an acrylic resin template relined by a resilient denture liner.

  12. Early subsidence of shape-closed hip arthroplasty stems is associated with late revision. A systematic review and meta-analysis of 24 RSA studies and 56 survival studies.

    Science.gov (United States)

    van der Voort, Paul; Pijls, Bart G; Nieuwenhuijse, Marc J; Jasper, Jorrit; Fiocco, Marta; Plevier, Josepha W M; Middeldorp, Saskia; Valstar, Edward R; Nelissen, Rob G H H

    2015-01-01

    Few studies have addressed the association between early migration of femoral stems and late aseptic revision in total hip arthroplasty. We performed a meta-regression analysis on 2 parallel systematic reviews and meta-analyses to determine the association between early migration and late aseptic revision of femoral stems. Of the 2 reviews, one covered early migration data obtained from radiostereometric analysis (RSA) studies and the other covered long-term aseptic revision rates obtained from survival studies with endpoint revision for aseptic loosening. Stems were stratified according to the design concept: cemented shape-closed, cemented force-closed, and uncemented. A weighted regression model was used to assess the association between early migration and late aseptic revision, and to correct for confounders. Thresholds for acceptable and unacceptable migration were determined in accordance with the national joint registries (≤ 5% revision at 10 years) and the NICE criteria (≤ 10% revision at 10 years). 24 studies (731 stems) were included in the RSA review and 56 studies (20,599 stems) were included in the survival analysis review. Combining both reviews for the 3 design concepts showed that for every 0.1-mm increase in 2-year subsidence, as measured with RSA, there was a 4% increase in revision rate for the shape-closed stem designs. This association remained after correction for age, sex, diagnosis, hospital type, continent, and study quality. The threshold for acceptable migration of shape-closed designs was defined at 0.15 mm; stems subsiding less than 0.15 mm in 2 years had revision rates of less than 5% at 10 years, while stems exceeding 0.15 mm subsidence had revision rates of more than 5%. There was a clinically relevant association between early subsidence of shape-closed femoral stems and late revision for aseptic loosening. This association can be used to assess the safety of shape-closed stem designs. The published research is not sufficient

  13. Communication Protocol for Advanced Prosthesis Components

    OpenAIRE

    Karnå, David

    2007-01-01

    It would be of great value for the prosthesis industry to achieve an open standard for communication in upper limb prostheses. Cooperation between NTNU and the University of New Brunswick has resulted in a functional requirements specification for such a standard, SCIP(Standardised Communication Interface in Prostheses). The special challenges for communication in a prosthesis system are possible noisy environments, high demands for light weight, safety for the user and the fact that devices ...

  14. Long-term effects of deep soil loosening on root distribution and soil physical parameters in compacted lignite mine soils

    Science.gov (United States)

    Badorreck, Annika; Krümmelbein, Julia; Raab, Thomas

    2015-04-01

    Soil compaction is a major problem of soils on dumped mining substrates in Lusatia, Germany. Deep ripping and cultivation of deep rooting plant species are considered to be effective ways of agricultural recultivation. Six years after experiment start, we studied the effect of initial deep soil loosening (i.e. down to 65 cm) on root systems of rye (Secale cereale) and alfalfa (Medicago sativa) and on soil physical parameters. We conducted a soil monolith sampling for each treatment (deep loosened and unloosened) and for each plant species (in three replicates, respectively) to determine root diameter, length density and dry mass as well as soil bulk density. Further soil physical analysis comprised water retention, hydraulic conductivity and texture in three depths. The results showed different reactions of the root systems of rye and alfalfa six years after deep ripping. In the loosened soil the root biomass of the rye was lower in depths of 20-40 cm and the root biomass of alfalfa was also decreased in depths of 20-50 cm together with a lower root diameter for both plant species. Moreover, total and fine root length density was higher for alfalfa and vice versa for rye. The soil physical parameters such as bulk density showed fewer differences, despite a higher bulk density in 30-40cm for the deep loosened rye plot which indicates a more pronounced plough pan.

  15. Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating.

    Science.gov (United States)

    Bacchi, Atais; Regalin, Alexandre; Bhering, Claudia Lopes Brilhante; Alessandretti, Rodrigo; Spazzin, Aloisio Oro

    2015-10-01

    The purpose of this study was to evaluate the influence of tightening technique and the screw coating on the loosening torque of screws used for Universal Abutment fixation after cyclic loading. Forty implants (Titamax Ti Cortical, HE, Neodent) (n=10) were submerged in acrylic resin and four tightening techniques for Universal Abutment fixation were evaluated: A - torque with 32 Ncm (control); B - torque with 32 Ncm holding the torque meter for 20 seconds; C - torque with 32 Ncm and retorque after 10 minutes; D - torque (32 Ncm) holding the torque meter for 20 seconds and retorque after 10 minutes as initially. Samples were divided into subgroups according to the screw used: conventional titanium screw or diamond like carbon-coated (DLC) screw. Metallic crowns were fabricated for each abutment. Samples were submitted to cyclic loading at 10(6) cycles and 130 N of force. Data were analyzed by two-way ANOVA and Tukey's test (5%). The tightening technique did not show significant influence on the loosening torque of screws (P=.509). Conventional titanium screws showed significant higher loosening torque values than DLC (P=.000). The use of conventional titanium screw is more important than the tightening techniques employed in this study to provide long-term stability to Universal Abutment screws.

  16. Fabrication of a Cranial Prosthesis Combined with an Ocular Prosthesis Using Rapid Prototyping: A Case Report

    Directory of Open Access Journals (Sweden)

    Gayatri Shankaran

    2016-08-01

    Full Text Available Rapid prototyping (RP is a technique of manufacturing parts by the additive layer manufacturing technology; where, a three-dimensional (3D model created in a computer aided design (CAD system is sectioned into 2D profiles, which are further constructed by RP layer by layer. Its use is not limited to industrial or engineering fields and has extended to the medical field for the manufacturing of custom implants and prostheses, the study of anatomy and surgical planning. Nowadays, dentists are more frequently encountered with the individuals affected with craniofacial defects due to trauma. In such cases, the cranio-maxillofacial rehabilitation is a real challenge to bring the patients back to society and promote their well-being. The conventional impression technique for facial prosthesis fabrication has the disadvantage of deforming the soft tissue and causing discomfort for the patient. Herein, we describe the fabrication of a cranial prosthesis combined with an ocular prosthesis with RP and stereolithography.

  17. Fabrication of a Cranial Prosthesis Combined with an Ocular Prosthesis Using Rapid Prototyping: A Case Report.

    Science.gov (United States)

    Shankaran, Gayatri; Deogade, Suryakant Chhagan; Dhirawani, Rajesh

    2016-01-01

    Rapid prototyping (RP) is a technique of manufacturing parts by the additive layer manufacturing technology; where, a three-dimensional (3D) model created in a computer aided design (CAD) system is sectioned into 2D profiles, which are further constructed by RP layer by layer. Its use is not limited to industrial or engineering fields and has extended to the medical field for the manufacturing of custom implants and prostheses, the study of anatomy and surgical planning. Nowadays, dentists are more frequently encountered with the individuals affected with craniofacial defects due to trauma. In such cases, the craniomaxillofacial rehabilitation is a real challenge to bring the patients back to society and promote their well-being. The conventional impression technique for facial prosthesis fabrication has the disadvantage of deforming the soft tissue and causing discomfort for the patient. Herein, we describe the fabrication of a cranial prosthesis combined with an ocular prosthesis with RP and stereolithography.

  18. Radiological evaluation of painful total hip replacement

    International Nuclear Information System (INIS)

    Tehranzadeh, J.; Schneider, R.; Freiberger, R.H.

    1981-01-01

    Ninety-four cases of clinically failed, cemented, total hip prostheses requiring surgery were reviewed to determine the accuracy of preoperative plain radiography, culture of aspirated fluid, arthrography, and bone scanning. When radiopaque cement had been used to embed the prosthesis, plain radiography was highly accurate in detecting a loose femoral component, less so in detecting a loose acetabular component. Culture of aspirated fluid was accurate in diagnosing infection. A positive arthrogram identified loosening with good accuracy; however, a negative arthrogram did not reliably exclude loosening. 99 mTc bone scans frequently differentiated loosening from loosening with infection. The suggested sequence of diagnostic tests is plain radiography followed by bone scanning. If the bone scan shows diffuse augmented uptake, culture of aspirated fluid followed by arthrography is indicated

  19. Metabolics of stair ascent with a powered transfemoral prosthesis.

    Science.gov (United States)

    Ledoux, E D; Lawson, B E; Shultz, A H; Bartlett, H L; Goldfarb, M

    2015-01-01

    This paper evaluates the effectiveness of a powered knee and ankle prosthesis for stair ascent through a metabolic assessment comparing energy expenditure of a single transfemoral amputee subject while ascending stairs with the powered prosthesis relative to his passive daily use device, as well as comparing the kinematics and kinetics obtained with the passive prosthesis to healthy biomechanics. The subject wore a portable system that measured pulmonary gaseous exchange rates of oxygen and carbon dioxide while he ascended stairs with each of the prostheses in alternating tests. The results indicated that the amputee's energy expenditure decreased by 32 percent while climbing with the powered prosthesis as compared to his passive one, and the kinematics and kinetics achieved were representative of healthy biomechanics.

  20. Irradiation as a means of sterilizing packaging materials for aseptic systems

    International Nuclear Information System (INIS)

    Blundell, M.J.

    1985-01-01

    Long shelf life of foodstuffs is essential in order to feed the nations of the world. For 'wet' products which quickly deteriorate in air, the use of refrigeration, retort processing and preservatives can be considered. For example, the metal can will continue to be a reliable means of keeping meat and vegetable products in good condition for long periods at ambient conditons. Today, people require food items to be free of preservatives and with a flavour and texture very close to the original, at all times of the year, at lowest cost. Minimal heat processing and immediate filling into a pre-sterilised container without any possibility of contact with the atmosphere, is the logical route to take to meet these requirements and constitutes an aseptic system. The filled product remains in prime condition for many months without the need for refrigeration and preservatives. Irradiation is a convenient and cheap means of pre-sterilising plastic bags for Bag-in-Box systems and the writer will describe how fruit juices and fruit purees are now being packaged aseptically in South Africa and overseas

  1. A systematic review of endoprosthetic replacement for non-tumour indications around the knee joint.

    Science.gov (United States)

    Korim, Muhammad T; Esler, Colin N A; Reddy, Venuthurla R M; Ashford, Robert U

    2013-12-01

    Endoprosthetic replacement (EPR) for limb salvage is an established treatment modality for orthopaedic malignancies around the knee. Increasingly, they are being used for non-tumour indications such as fractures, bone loss associated with aseptic loosening, septic loosening and ligament insufficiencies. We reviewed the evolution and biomechanics of knee EPRs. MEDLINE was searched using the PubMed interface to identify relevant studies pertaining to the use of knee EPRs in non-tumour conditions. Failures, mortality and knee scores were the main outcome measures. Subgroup analysis in the non-tumour conditions was also performed. There were nine studies with an average follow-up of 3.3years (Range 1-5years) describing 241 EPRs used in non-tumour conditions. Re-operation for any reason occurred in 17% (41/241) of cases. The most common complication was infection (15%) followed by aseptic loosening (5%) and periprosthetic fractures (5%). The mortality rate averaged 22%. Infected knee arthroplasties were less likely to have a successful outcome when salvaged with an EPR with failure rates up to 33%. Endoprosthetic replacement is a limb salvage option when other surgical options are unfeasible, especially in low demand elderly patients with limited life expectancy. They have low rates of failure in the medium term. Level 1. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. [Serotype distribution of enteroviruses isolated from paediatric cases prediagnosed as aseptic meningitis between 2001-2004 period].

    Science.gov (United States)

    Ozkaya, Etem; Uysal, Gülnar; Atak, Tunca; Alkan, Mehmet

    2005-01-01

    Enteroviruses have major clinical and public health importance and are one of the leading causes of aseptic meningitis. There are many diseases with similar clinical symptoms and cerebrospinal fluid (CSF) findings of aseptic meningitis, thus virus isolation and identification is crucial for definitive diagnosis. Virological diagnosis is nonetheless important to distinguish between induced meningitis and other treatable causes of disease with a similar clinical picture. A total of 249 samples obtained from 246 cases (age range: 0-15 years), prediagnosed as aseptic meningitis, were sent to Virology Laboratory of Refik Saydam Hygiene Center. The patients were followed at Department of Pediatric Infectious Diseases in the Social Security Hospital, Ankara, Turkey, between 2001 and 2004. Stool (n: 180), CSF (n: 54) and throat swab (n: 15) samples have been inoculated to RD (rhabdomyosarcoma), Hep-2 (human epithelioma) and L20B (transgenic mice) cell lines, and followed up for the presence of cytopathic effects. A total of 95 enterovirus strains were isolated from 85 (34.6%) cases, and serotyped by using RIVM (National Institute of Public and the Environment, Nederlands) antisera with microneutralization method. As a result, the most frequently isolated types were found as echovirus type 30 (n: 24) and coxsackievirus type B (n: 19), which were most frequently isolated between July to October. This is the first report from Turkey for aseptic meningitis cases due to echovirus type 25 (n:3), 18 (n:2), 14 (n:1), 13 (n:4), 11 (n:6), 9 (n:1), 6 (n:9), 5 (n:1), 4 (n:1) and coxsackievirus type A9 (n:1).

  3. [Treatment of periprosthetic femoral fractures after total hip arthroplasty with specially constructed retrograde hollow nails].

    Science.gov (United States)

    Szalay, G; Meyer, C; Mika, J; Schnettler, R; Thormann, U

    2014-12-01

    Treatment of periprosthetic fractures by implantation of a specially constructed, retrograde hollow nail which fits over the tip of the prosthesis and becomes locked on it. Periprosthetic femoral fractures with firmly anchored prosthesis shaft after total hip arthroplasty of types B1 and C according to the Vancouver classification. Loosened prosthesis (type B2/B3) and trochanteric fractures (type A). Broken or damaged prosthesis, florid inflammation and soft tissue injuries in the operation field, contracted knee joint, advanced deformation in the knee joint and distal femur, enclosed prosthesis and general contraindications. In a supine position the periprosthetic fracture is exposed via a lateral access. For cemented prostheses the cement is removed around the tip of the prosthesis (at least 2-3 cm) and medullary cavity. Arthrotomy with flexion of the knee joint and marking of the nail entry point. Drill the medullary cavity, retrograde introduction of the nail, visually fit the nail over the tip of the prosthesis and lock the nail with the prosthesis. If necessary use additional spongiosaplasty or also placement of additional cerclages depending on fracture type and size of the defect zone. Lock the nail distally. Use intraoperative radiological imaging to control correct positioning and length of the nail. Close the wound layer by layer with placement of suction drainage devices and dressing. Partial loading for 6 weeks with a subsequent pain-adapted loading gradient until full loading is possible. If selective partial loading is not possible, a decision must be made in individual cases as to whether the intraoperative findings allow immediate full loading. From 2004 to 2011 a total of 25 periprosthetic femoral fractures in 25 patients were treated in 2 locations using specially constructed slotted hollow nails. Within the framework of a retrospective study 20 of these patients (16 female and 4 male; average age 77.2 [72-84] years) were clinically and

  4. Penile prosthesis implant: scientific advances and technological innovations over the last four decades.

    Science.gov (United States)

    Chung, Eric

    2017-02-01

    Despite introduction of oral phosphodiesterase type 5 inhibitors and intracavernosal vasoactive agents, penile prosthesis implant remains a relevant and desired option with sales of penile prostheses continue to stay high, as many men became refractory to medical therapy and/or seeking a more effective and permanent therapy. There are two types of penile prosthesis implants: inflatable and non-inflatable types, and the inflatable penile implants can be subdivided into single-, two- and three-piece devices. Non-inflatable penile prosthesis (non-IPP) may be referred to as semi-rigid rod or malleable prosthesis. IPP is considered a superior option to malleable prosthesis as it produces penile rigidity and flaccidity that closely replicates a normal penile erectile function. Since the introduction of IPP by Scott in 1973, surgical landscape for penile prosthesis implantation has changed dramatically. Advances in prosthesis design, device technologies and surgical techniques have made penile prosthesis implant a more natural, durable and reliable device. The following article reviews the scientific advances and technological innovation in modern penile prosthesis implants over the last four decades.

  5. High complication rate in reconstruction of Paprosky type IIIa acetabular defects using an oblong implant with modular side plates and a hook.

    Science.gov (United States)

    Babis, G C; Sakellariou, V I; Chatziantoniou, A N; Soucacos, P N; Megas, P

    2011-12-01

    We report the results of 62 hips in 62 patients (17 males, 45 females) with mean age of 62.4 years (37 to 81), who underwent revision of the acetabular component of a total hip replacement due to aseptic loosening between May 2003 and November 2007. All hips had a Paprosky type IIIa acetabular defect. Acetabular revision was undertaken using a Procotyl E cementless oblong implant with modular side plates and a hook combined with impaction allografting. At a mean follow-up of 60.5 months (36 to 94) with no patients lost to follow-up and one died due to unrelated illness, the complication rate was 38.7%. Complications included aseptic loosening (19 hips), deep infection (3 hips), broken hook and side plate (one hip) and a femoral nerve palsy (one hip). Further revision of the acetabular component was required in 18 hips (29.0%) and a further four hips (6.4%) are currently loose and awaiting revision. We observed unacceptably high rates of complication and failure in our group of patients and cannot recommend this implant or technique.

  6. Automated estimation of hip prosthesis migration: a feasibility study

    Science.gov (United States)

    Vandemeulebroucke, Jef; Deklerck, Rudi; Temmermans, Frederik; Van Gompel, Gert; Buls, Nico; Scheerlinck, Thierry; de Mey, Johan

    2013-09-01

    A common complication associated with hip arthoplasty is prosthesis migration, and for most cemented components a migration greater than 0.85 mm within the first six months after surgery, are an indicator for prosthesis failure. Currently, prosthesis migration is evaluated using X-ray images, which can only reliably estimate migrations larger than 5 mm. We propose an automated method for estimating prosthesis migration more accurately, using CT images and image registration techniques. We report on the results obtained using an experimental set-up, in which a metal prosthesis can be translated and rotated with respect to a cadaver femur, over distances and angles applied using a combination of positioning stages. Images are first preprocessed to reduce artefacts. Bone and prosthesis are extracted using consecutive thresholding and morphological operations. Two registrations are performed, one aligning the bones and the other aligning the prostheses. The migration is estimated as the difference between the found transformations. We use a robust, multi-resolution, stochastic optimization approach, and compare the mean squared intensity differences (MS) to mutual information (MI). 30 high-resolution helical CT scans were acquired for prosthesis translations ranging from 0.05 mm to 4 mm, and rotations ranging from 0.3° to 3° . For the translations, the mean 3D registration error was found to be 0.22 mm for MS, and 0.15 mm for MI. For the rotations, the standard deviation of the estimation error was 0.18° for MS, and 0.08° for MI. The results show that the proposed approach is feasible and that clinically acceptable accuracies can be obtained. Clinical validation studies on patient images will now be undertaken.

  7. Availability of Dental Prosthesis Procedures in Brazilian Primary Health Care

    Directory of Open Access Journals (Sweden)

    Maria Aparecida Gonçalves Melo Cunha

    2018-01-01

    Full Text Available Objectives. To describe dental prosthesis provision in the Brazilian public health service and report the performance of dental prosthesis procedures according to the Brazilian macroregions. Methods. A structured interview was conducted with senior-level health professionals from each of the 18,114 oral health teams (OHT. The dependent variables were performance of removable prostheses and prosthesis procedures, including provision of fixed prostheses by OHT. Descriptive statistics were produced together with performing a cluster analysis using SPSS version 19.0. Results. The manufacture of any type of prosthesis was done by a minority of OHT (43%. The most commonly provided types of dental prosthesis were removable full and partial dentures. Cluster 1 (teams that performed prosthesis procedures the most was composed of a smaller number of teams (n = 5,531, and Cluster 2 (composed of teams that do not perform prosthetics or that perform them in small amounts consisted of 12,583 teams. The geographic distribution of clusters reveals that the largest proportion of Cluster 1 teams is located in the Northeast (33.9% and Southeast (33.6%. Conclusions. A minority of OHT produce dental prostheses. There is an unequal geographical distribution of clusters.

  8. Amputation and prosthesis implantation shape body and peripersonal space representations.

    Science.gov (United States)

    Canzoneri, Elisa; Marzolla, Marilena; Amoresano, Amedeo; Verni, Gennaro; Serino, Andrea

    2013-10-03

    Little is known about whether and how multimodal representations of the body (BRs) and of the space around the body (Peripersonal Space, PPS) adapt to amputation and prosthesis implantation. In order to investigate this issue, we tested BR in a group of upper limb amputees by means of a tactile distance perception task and PPS by means of an audio-tactile interaction task. Subjects performed the tasks with stimulation either on the healthy limb or the stump of the amputated limb, while wearing or not wearing their prosthesis. When patients performed the tasks on the amputated limb, without the prosthesis, the perception of arm length shrank, with a concurrent shift of PPS boundaries towards the stump. Conversely, wearing the prosthesis increased the perceived length of the stump and extended the PPS boundaries so as to include the prosthetic hand, such that the prosthesis partially replaced the missing limb.

  9. Management of long span partially edentulous maxilla with fixed removable denture prosthesis.

    Science.gov (United States)

    Jeyavalan, Mahilan I; Narasimman, M; Venkatakrishnan, C J; Philip, Jacob M

    2012-07-01

    Restoration of a long span partially edentulous maxilla with tooth supported prosthesis is challenging because of inherent anatomic limitations and unfavourable biomechanics present after the loss of teeth. A tooth supported fixed-removable prosthesis is a treatment option for restoration of such long span partially edentulous maxillary arches. This prosthesis meets the requirements for esthetics, phonetics, comfort, and hygiene, as well as favourable biomechanical stress distribution to the remaining natural tooth abutments. This article presents a procedure for fabrication of a fixed-removable prosthesis that has cement-retained custom cast bar metal substructure and a ball attachment retained removable superstructure prosthesis.

  10. Dosimetric influence of hip prosthesis during radiotherapeutic treatment

    International Nuclear Information System (INIS)

    Gschwind, R.; Buffard, E.; Masset, H.; Makovicka, L.; David, C.; David, C.; Buffard, E.

    2008-01-01

    As the population become aged, many patients with hip prosthesis are treated for a pelvic cancer. The recommended ballistic must avoid to pass in the prosthesis, but sometimes it is inevitable. So it is essential to quantify with accuracy the dose modifications linked to the presence of metallic implant. The aim of this study is to analyze by Monte Carlo method these modifications in simple and complex models (anthropomorphic phantom) which take into account the geometry and the composition of the prosthesis and its coatings. Then, this methodology was used to study the behaviour of a treatment planning system in theses extreme conditions. (authors)

  11. Impact of hip prosthesis on dose distribution of pelvic radiotherapy

    International Nuclear Information System (INIS)

    Ren Jiangping; Zhang Songfang; Zhu Qibao; Guo Jianxin; Zha Yuanzi

    2011-01-01

    Objective: To study the scattering effect of Co-Cr-Mo hip prosthesis which was high Z material for patients undergoing pelvic irradiation. Methods: The hip prosthesis was set in water phantom (30 cm x 30 cm x 30 cm), determining points were chosen on the entrance side of both 6 MV and 10 MV beams at the distance of 0.5 cm, 1.0 cm, 2.0 cm to the hip prosthesis, and also on the exit side of both 6 MV and 10 MV beams at the distance of 3.0 cm, 5.0 cm, 7.0 cm to the hip prostheses. Dose behind the hip prosthesis at depths of 5.0 cm and 10.0 cm for 6 MV and 10 MV beams are also measured. Results: The dose deviation on the beams' entrance side is between 0 to 5.0%, the backscatter effect was more obviously with the higher energy beam. The dose deviation on the beams' exit side was between 21.6%-30.8%. With the same field size and depth, dose deviation becomes smaller when the beam energy was higher; while with the same energy and depth, dose deviation becomes smaller when the field size was bigger. Dose profiles behind the head of the hip prosthesis indicate obvious attenuation of the beam. Conclusions: Beam arrangements that avoid the prosthesis should be considered first or we should at least reduce the weight of the beam that pass through the prosthesis. (authors)

  12. 21 CFR 888.3810 - Wrist joint ulnar (hemi-wrist) polymer prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint ulnar (hemi-wrist) polymer prosthesis. 888.3810 Section 888.3810 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-wrist) polymer prosthesis. (a) Identification. A wrist joint ulnar (hemi-wrist) polymer prosthesis...

  13. 21 CFR 888.3730 - Toe joint phalangeal (hemi-toe) polymer prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Toe joint phalangeal (hemi-toe) polymer prosthesis. 888.3730 Section 888.3730 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-toe) polymer prosthesis. (a) Identification. A toe joint phalangeal (hemi-toe) polymer prosthesis...

  14. Distribuce otěrových částic UHMWPE v periprotetických tkáních u TEP kyčelního kloubu

    Czech Academy of Sciences Publication Activity Database

    Pokorný, D.; Šlouf, Miroslav; Veselý, F.; Fulín, P.; Jahoda, D.; Sosna, A.; Běláček, J.; Landor, I.; Zolotarevova, E.; Popelka, S.

    2010-01-01

    Roč. 77, č. 2 (2010), s. 87-92 ISSN 0001-5415 R&D Projects: GA MŠk 2B06096 Institutional research plan: CEZ:AV0Z40500505 Keywords : total hip replacement * polyethylene wear * aseptic loosening Subject RIV: CD - Macromolecular Chemistry Impact factor: 1.628, year: 2009 http://www.achot.cz/detail.php?stat=346

  15. Penile Corporeal Reconstruction during Difficult Placement of a Penile Prosthesis

    Directory of Open Access Journals (Sweden)

    Viet Q. Tran

    2008-01-01

    Full Text Available For some patients with impotence and concomitant severe tunical/corporeal tissue fibrosis, insertion of a penile prosthesis is the only option to restore erectile function. Closing the tunica over an inflatable penile prosthesis in these patients can be challenging. We review our previous study which included 15 patients with severe corporeal or tunical fibrosis who underwent corporeal reconstruction with autologous rectus fascia to allow placement of an inflatable penile prosthesis. At a mean follow-up of 18 months (range 12 to 64, all patients had a prosthesis that was functioning properly without evidence of separation, herniation, or erosion of the graft. Sexual activity resumed at a mean time of 9 weeks (range 8 to 10. There were no adverse events related to the graft or its harvest. Use of rectus fascia graft for coverage of a tunical defect during a difficult penile prosthesis placement is surgically feasible, safe, and efficacious.

  16. Design and Control of a Pneumatically Actuated Transtibial Prosthesis.

    Science.gov (United States)

    Zheng, Hao; Shen, Xiangrong

    2015-04-01

    This paper presents the design and control of a pneumatically actuated transtibial prosthesis, which utilizes a pneumatic cylinder-type actuator to power the prosthetic ankle joint to support the user's locomotion. The pneumatic actuator has multiple advantages over the traditional electric motor, such as light weight, low cost, and high power-to-weight ratio. The objective of this work is to develop a compact and lightweight transtibial prosthesis, leveraging the multiple advantages provided by this highly competitive actuator. In this paper, the design details of the prosthesis are described, including the determination of performance specifications, the layout of the actuation mechanism, and the calculation of the torque capacity. Through the authors' design calculation, the prosthesis is able to provide sufficient range of motion and torque capacity to support the locomotion of a 75 kg individual. The controller design is also described, including the underlying biomechanical analysis and the formulation of the finite-state impedance controller. Finally, the human subject testing results are presented, with the data indicating that the prosthesis is able to generate a natural walking gait and sufficient power output for its amputee user.

  17. Aseptic necrosis of the femoral head after pregnancy: a case report

    OpenAIRE

    Nassar, Kawtar; Rachidi, Wafae; Janani, Saadia; Mkinsi, Ouafa

    2016-01-01

    A documented case of beginning aseptic necrosis of the femoral head associated with pregnancy together with a review of the literature about this rare complication of pregnancy is presented. The known risk factors of osteonecrosis are; steroid use, alcoholism, organ transplantation, especially after kidney transplant or bone marrow transplantation bone, systemic lupus erythematosus, dyslipidemia especially hypertriglyceridemia, dysbaric decompression sickness, drepanocytosis and Gaucher's dis...

  18. Waterjet cutting of periprosthetic interface tissue in loosened hip prostheses: an in vitro feasibility study

    NARCIS (Netherlands)

    Kraaij, Gert; Tuijthof, Gabrielle J. M.; Dankelman, Jenny; Nelissen, Rob G. H. H.; Valstar, Edward R.

    2015-01-01

    Waterjet cutting technology is considered a promising technology to be used for minimally invasive removal of interface tissue surrounding aseptically loose hip prostheses. The goal of this study was to investigate the feasibility of waterjet cutting of interface tissue membrane. Waterjets with 0.2

  19. Prosthesis rejection in acquired major upper-limb amputees: a population-based survey.

    Science.gov (United States)

    Østlie, Kristin; Lesjø, Ingrid Marie; Franklin, Rosemary Joy; Garfelt, Beate; Skjeldal, Ola Hunsbeth; Magnus, Per

    2012-07-01

    To estimate the rates of primary and secondary prosthesis rejection in acquired major upper-limb amputees (ULAs), to describe the most frequently reported reasons for rejection and to estimate the influence of background factors on the risk of rejection. Cross-sectional study analysing population-based questionnaire data (n = 224). Effects were analysed by logistic regression analyses and Cox regression analyses. Primary prosthesis rejection was found in 4.5% whereas 13.4% had discontinued prosthesis use. The main reasons reported for primary non-wear were a perceived lack of need and discrepancies between perceived need and the prostheses available. The main reasons reported for secondary prosthesis rejection were dissatisfaction with prosthetic comfort, function and control. Primary prosthesis rejection was more likely in ULAs amputated at high age and in ULAs with proximal amputations. Secondary prosthesis rejection was more likely in proximal ULAs and in women. Clinicians should be aware of the increased risk of rejection in proximal ULAs, elderly ULAs and in women. Emphasising individual needs will probably facilitate successful prosthetic fitting. Improved prosthesis quality and individualised prosthetic training may increase long-term prosthesis use. Further studies of the effect of prosthetic training and of the reasons for rejection of different prosthetic types are suggested.

  20. Human prosthetic joint infections are associated with myeloid-derived suppressor cells (MDSCs): Implications for infection persistence.

    Science.gov (United States)

    Heim, Cortney E; Vidlak, Debbie; Odvody, Jessica; Hartman, Curtis W; Garvin, Kevin L; Kielian, Tammy

    2017-11-15

    Prosthetic joint infection (PJI) is a devastating complication of joint arthroplasty surgery typified by biofilm formation. Currently, mechanisms whereby biofilms persist and evade immune-mediated clearance in immune competent patients remain largely ill-defined. Therefore, the current study characterized leukocyte infiltrates and inflammatory mediator expression in tissues from patients with PJI compared to aseptic loosening. CD33 + HLA-DR - CD66b + CD14 -/low granulocytic myeloid-derived suppressor cells (G-MDSCs) were the predominant leukocyte population at sites of human PJI compared to aseptic tissues. MDSCs inhibit T cell proliferation, which coincided with reduced T cells in PJIs compared to aseptic tissues. IL-10, IL-6, and CXCL1 were significantly elevated in PJI tissues and have been implicated in MDSC inhibitory activity, expansion, and recruitment, respectively, which may account for their preferential increase in PJIs. This bias towards G-MDSC accumulation during human PJI could account for the chronicity of these infections by preventing the pro-inflammatory, antimicrobial actions of immune effector cells. Animal models of PJI have revealed a critical role for MDSCs and IL-10 in promoting infection persistence; however, whether this population is prevalent during human PJI and across distinct bacterial pathogens remains unknown. This study has identified that granulocytic-MDSC infiltrates are unique to human PJIs caused by distinct bacteria, which are not associated with aseptic loosening of prosthetic joints. Better defining the immune status of human PJIs could lead to novel immune-mediated approaches to facilitate PJI clearance in combination with conventional antibiotics. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  1. Management of long span partially edentulous maxilla with fixed removable denture prosthesis

    Directory of Open Access Journals (Sweden)

    Mahilan I Jeyavalan

    2012-01-01

    Full Text Available Restoration of a long span partially edentulous maxilla with tooth supported prosthesis is challenging because of inherent anatomic limitations and unfavourable biomechanics present after the loss of teeth. A tooth supported fixed-removable prosthesis is a treatment option for restoration of such long span partially edentulous maxillary arches. This prosthesis meets the requirements for esthetics, phonetics, comfort, and hygiene, as well as favourable biomechanical stress distribution to the remaining natural tooth abutments. This article presents a procedure for fabrication of a fixed-removable prosthesis that has cement-retained custom cast bar metal substructure and a ball attachment retained removable superstructure prosthesis.

  2. 21 CFR 872.3970 - Interarticular disc prosthesis (interpositional implant).

    Science.gov (United States)

    2010-04-01

    ... implant). 872.3970 Section 872.3970 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3970 Interarticular disc prosthesis (interpositional implant). (a) Identification. An interarticular disc prosthesis...

  3. Reading visual braille with a retinal prosthesis.

    Science.gov (United States)

    Lauritzen, Thomas Z; Harris, Jordan; Mohand-Said, Saddek; Sahel, Jose A; Dorn, Jessy D; McClure, Kelly; Greenberg, Robert J

    2012-01-01

    Retinal prostheses, which restore partial vision to patients blinded by outer retinal degeneration, are currently in clinical trial. The Argus II retinal prosthesis system was recently awarded CE approval for commercial use in Europe. While retinal prosthesis users have achieved remarkable visual improvement to the point of reading letters and short sentences, the reading process is still fairly cumbersome. This study investigates the possibility of using an epiretinal prosthesis to stimulate visual braille as a sensory substitution for reading written letters and words. The Argus II retinal prosthesis system, used in this study, includes a 10 × 6 electrode array implanted epiretinally, a tiny video camera mounted on a pair of glasses, and a wearable computer that processes the video and determines the stimulation current of each electrode in real time. In the braille reading system, individual letters are created by a subset of dots from a 3 by 2 array of six dots. For the visual braille experiment, a grid of six electrodes was chosen out of the 10 × 6 Argus II array. Groups of these electrodes were then directly stimulated (bypassing the camera) to create visual percepts of individual braille letters. Experiments were performed in a single subject. Single letters were stimulated in an alternative forced choice (AFC) paradigm, and short 2-4-letter words were stimulated (one letter at a time) in an open-choice reading paradigm. The subject correctly identified 89% of single letters, 80% of 2-letter, 60% of 3-letter, and 70% of 4-letter words. This work suggests that text can successfully be stimulated and read as visual braille in retinal prosthesis patients.

  4. Testicular prosthesis: Patient satisfaction and sexual dysfunctions in testis cancer survivors.

    Science.gov (United States)

    Catanzariti, Francesco; Polito, Benedetta; Polito, Massimo

    2016-10-05

    We studied patient satisfaction about sexual activity after prosthesis implantation using validated questionnaires with the aim to discover if testicular prosthesis could be responsible of sexual dysfunctions (erectile dysfunction or premature ejaculation). We evaluated a total of 67 men who underwent radical orchiectomy for testicular cancer and a silicon testicular prosthesis implantation from January 2008 to June 2014 at our Hospital. These patients completed 5 validated questionnaires the day before orchiectomy and 6 months after surgery: the International Index of Erectile Function 5 (IIEF5), the Premature Ejaculation Diagnostic Tool (PEDT), the Body Exposure during Sexual Activities Questionnaire (BESAQ), the Body-Esteem Scale and the Rosenberg Self- Esteem Scale. We also evaluated 6 months after surgery any defects of the prosthesis complained by the patients. The questionnaires completed by patients didn't show statistically significant changes for erectile dysfunction (p > 0.05) and premature ejaculation (p > 0.05). On the contrary the psychological questionnaires showed statistically significant change for the BESAQ (p < 0.001) and the Body Esteem Scale (p < 0.001), but not for the Rosenberg Self-Esteem Scale (p > 0,05). A total of 15 patients (22.37%) were dissatisfied about the prosthesis: the most frequent complaint (8 patients; 11.94%) was that the prosthesis was firmer than the normal testis. Testicular prosthesis implantation is a safe surgical procedure that should be always proposed before orchiectomy for cancer of the testis. The defects complained by patients with testicular prosthesis are few, they don't influence sexual activity and they aren't able to cause erectile dysfunction or premature ejaculation.

  5. Nasal prosthesis for a patient with xeroderma pigmentosum

    Directory of Open Access Journals (Sweden)

    Suresh Kumar

    2013-01-01

    Full Text Available Acquired facial defects caused by extirpation of neoplasms, congenital malformations or traumatic injury results in a huge functional, cosmetic and psychological handicap in those patients. These defects can be restored by facial prosthesis using different materials and retention methods to achieve a lifelike appearance and function. This clinical report describes a treatment schedule using silicone nasal prosthesis, which is mechanically retained for a patient who has undergone a partial rhinectomy due to basal cell carcinoma of the nose. The prosthesis was made to restore the esthetic appearance of patient with a mechanically retained design using a spectacle glass frame without any prosthetic adhesives so that the patient is more comfortable and confident to resume daily activities.

  6. Herpes simplex virus type 2-associated recurrent aseptic (Mollaret's meningitis in genitourinary medicine clinic: a case report

    Directory of Open Access Journals (Sweden)

    Abou-Foul AK

    2014-03-01

    Full Text Available Ahmad K Abou-Foul, Thajunisha M Buhary, Sedki L Gayed Department of Genitourinary Medicine, Royal Blackburn Hospital, East Lancashire Hospitals NHS Trust, Blackburn, UK Introduction: Cases of idiopathic recurrent benign aseptic meningitis were first described by Mollaret. Today, herpes simplex virus (HSV is considered the cause of most cases of Mollaret's meningitis. Case report: A 40-year-old male was referred to our genitourinary medicine clinic with recurrent genital herpetic lesions. He had HSV-2-positive genital ulcers 8 years earlier. One year after the first infection, he developed severe recurrent attacks of headache associated with meningitis symptoms. The results of all radiological and biochemical tests were normal, but the patient reported a correlation between his attacks and genital herpes flare-ups. We diagnosed the patient with Mollaret's meningitis and started him on continuous suppressive acyclovir therapy, which resulted in marked clinical improvement. Discussion: Mollaret's meningitis is a rare form of idiopathic recurrent aseptic meningitis that has a sudden onset, short duration, and spontaneous remission with unpredictable recurrence. We believe that the presence of concurrent or recurrent mucocutaneous herpetic lesions can aid its diagnosis, prior to which, affected patients usually have many unnecessary investigations and treatments. Therefore, detailed sexual history should be sought in all patients with aseptic meningitis, and clinicians should also ask about history of recurrent headaches in all patients with recurrent herpetic anogenital lesions. Continuous suppressive acyclovir therapy may reduce the frequency and severity of attacks and can dramatically improve lifestyle. Keywords: HSV-2 virus, acyclovir, Mollaret's meningitis, recurrent aseptic meningitis, HSV-2 virus, viral meningitis, acyclovir

  7. Control and Evaluation of a Powered Transfemoral Prosthesis for Stair Ascent.

    Science.gov (United States)

    Ledoux, Elissa D; Goldfarb, Michael

    2017-07-01

    This paper assesses the metabolic effort exerted by three transfemoral amputees, when using a powered knee and ankle prosthesis for stair ascent, relative to ascending stairs with passive knee and ankle prostheses. The paper describes a controller that provides step-over stair ascent behavior reflective of healthy stair ascent biomechanics, and describes its implementation in a powered prosthesis prototype. Stair ascent experiments were performed with three unilateral transfemoral amputee subjects, comparing the oxygen consumption required to ascend stairs using the powered prosthesis (with a step-over gait), relative to using their daily-use energetically passive prostheses (with a step-to gait). Results indicate on average a 24% reduction in oxygen consumption and a 30% reduction in stair ascent timewhen using the powered prosthesis, relative to when using the passive prostheses. All subjects expressed a strong preference for ascending stairs using the powered prosthesis.

  8. Candida infection of a prosthetic shoulder joint

    Energy Technology Data Exchange (ETDEWEB)

    Lichtman, E.A.

    1983-09-01

    A heroin addict developed a Candida parapsilosis infection in a prosthetic shoulder joint. Radiographs showed loose fragments of cement with prosthetic loosening. The patient was treated with removal of the prosthesis and intravenous amphotericin B followed by oral ketoconazole.

  9. Periprothetische Femurfrakturen nach Hüftgelenksersatz: Rationale für die intra- oder extramedulläre Behandlung

    DEFF Research Database (Denmark)

    Haag, C.; Seif El Nasr, M.; Schmal, H.

    2000-01-01

    stabilized by tension wires, 29 by extramedullary plate osteosynthesis (19 LCDCP, 10 condylar plates) and 20 with a cancellous bone graft. In 14 cases the prosthesis was replaced. The total complication rate was expected fairly high (12 cases, 26.6%), considering age and general health of our investigated...... population of patients. Only 2 patients could be sent home after operation, following a 14-day hospital stay. The analysis of this population of patients shows that a preexisting stress such as osteoporosis, a previous successful prosthesis replacement and loosening of the prosthesis increases the likelihood...... of an occurring periprosthetic fracture. The region around the tip of the prosthesis is particularly endangered to undergo a fracture in case of an impact. After the replacement of a prosthesis, older patients benefit from early mobility and exercise....

  10. Prosthetic rehabilitation of large mid-facial defect with magnet-retained silicone prosthesis

    Directory of Open Access Journals (Sweden)

    Kirti Jajoo Shrivastava

    2015-01-01

    Full Text Available Rehabilitation of maxillofacial defect patients is a challenging task. The most common prosthetic treatment problem with such patients is, getting adequate retention, stability, and support. In cases of large maxillofacial defect, movement of the prosthesis is inevitable. The primary objectives in rehabilitating the maxillofacial defect patients are to restore the function of mastication, deglutition, speech, and to achieve normal orofacial appearance. This clinical report describes maxillofacial prosthetic rehabilitation of large midfacial defect including orbit along with its contents, zygoma and soft tissues including half of the nose, cheeks, upper lip of left side, accompanying postsurgical microstomia and orofacial communication, which resulted from severe fungal infection mucormycosis. The defect in this case was restored with magnet retained two piece maxillofacial prosthesis having hollow acrylic resin framework and an overlying silicone facial prosthesis. The retention of prosthesis was further enhanced with the use of spectacles. This type of combination prosthesis enhanced the cosmesis and functional acceptability of prosthesis.

  11. Irradiated or aseptically prepared frozen dairy desserts: acceptability to bone marrow transplant recipients

    International Nuclear Information System (INIS)

    Dong, F.M.; Hashisaka, A.E.; Rasco, B.A.; Einstein, M.A.; Mar, D.R.; Aker, S.N.

    1992-01-01

    Sterile ice cream and frozen yogurt were offered to immunosuppressed patients recovering from bone marrow transplantation. To obtain sterile products, two of the dairy desserts (prepackaged ice cream and frozen yogurt bars) were exposed to 40 kGy of cobalt 60 irradiation. Four different flavors of ice cream were aseptically prepared under a laminar airflow hood using commercially sterilized ingredients. A commercially sterile, frozen milk-based drink on the low-microbial menu served as the control. Ratings of the seven products by 17 patients indicated that a frozen vanilla milk-based drink and aseptically prepared chocolate ice cream were highly acceptable to recovering immunosuppressed patients who have difficulty eating most foods. However, the seven desserts received higher ratings from a sensory panel of healthy individuals than from the patient panel, confirming that new foods for the low-microbial diet should be ''market-tested'' by the targeted patient population before inclusion in the menu

  12. Irradiated or aseptically prepared frozen dairy desserts: acceptability to bone marrow transplant recipients.

    Science.gov (United States)

    Dong, F M; Hashisaka, A E; Rasco, B A; Einstein, M A; Mar, D R; Aker, S N

    1992-06-01

    Sterile ice cream and frozen yogurt were offered to immunosuppressed patients recovering from bone marrow transplantation. To obtain sterile products, two of the dairy desserts (prepackaged ice cream and frozen yogurt bars) were exposed to 40 kGy of cobalt 60 irradiation. Four different flavors of ice cream were aseptically prepared under a laminar airflow hood using commercially sterilized ingredients. A commercially sterile, frozen milk-based drink on the low-microbial menu served as the control. Ratings of the seven products by 17 patients indicated that a frozen vanilla milk-based drink and aseptically prepared chocolate ice cream were highly acceptable to recovery immunosuppressed patients who have difficulty eating most foods. However, the seven desserts received higher ratings from a sensory panel of healthy individuals than from the patient panel, confirming that new foods for the low-microbial diet should be "market-tested" by the targeted patient population before inclusion in the menu.

  13. Function of obturator prosthesis after maxillectomy and prosthetic obturator rehabilitation

    Directory of Open Access Journals (Sweden)

    Cheng Chen

    2016-04-01

    Full Text Available ABSTRACT INTRODUCTION: Maxillary defects are usually rehabilitated by a prosthetic obturator. OBJECTIVE: This study aimed to evaluate the functioning of obturators prosthesis in patients with unilateral defects after maxillectomy. METHODS: Of 49 patients, 28 underwent to maxillectomy as a result of tumor ablative surgery, and acquired unilateral maxillary defects. Evaluation of the function was performed by applying the Obturator Functional Scale (OFS. RESULTS: From a total of 49 patients, 28 were treated as follows: 9 with a conventional retained obturator prosthesis (COP, 11 (39% with an enhanced retentive obturator prosthesis with stud attachment (POP and 8 (28% with an enhanced retentive obturator prosthesis with magnetic attachment (POM. The mean OFS score was 80. Scores on functions of speech, swallowing and chewing reached statistical significances (p < 0.05 among these three subgroups. Comparing COP and MOP groups, the scores of OFS in the domains of "Speech-ability to speak in public" and "Swallowing-leakage with liquids" were significantly higher in AOP group. Comparing COP group, the scores of OFS in "Swallowing-leakage with solid" and "Chewing/eating" domains were increased significantly (p < 0.05 both in MOP and AOP groups. CONCLUSION: Obturator prosthesis improves oral function of patients after maxillary defects; the retention of the obturator prosthesis enhanced by the addition of attachments showed more benefits in oral function.

  14. Testicular prosthesis: Patient satisfaction and sexual dysfunctions in testis cancer survivors

    Directory of Open Access Journals (Sweden)

    Francesco Catanzariti

    2016-10-01

    Full Text Available Purpose: We studied patient satisfaction about sexual activity after prosthesis implantation using validated questionnaires with the aim to discover if testicular prosthesis could be responsible of sexual dysfunctions (erectile dysfunction or premature ejaculation. Materials and Methods: We evaluated a total of 67 men who underwent radical orchiectomy for testicular cancer and a silicon testicular prosthesis implantation from January 2008 to June 2014 at our Hospital. These patients completed 5 validated questionnaires the day before orchiectomy and 6 months after surgery: the International Index of Erectile Function 5 (IIEF5, the Premature Ejaculation Diagnostic Tool (PEDT, the Body Exposure during Sexual Activities Questionnaire (BESAQ, the Body-Esteem Scale and the Rosenberg Self- Esteem Scale. We also evaluated 6 months after surgery any defects of the prosthesis complained by the patients. Results: The questionnaires completed by patients didn’t show statistically significant changes for erectile dysfunction (p > 0.05 and premature ejaculation (p > 0.05. On the contrary the psychological questionnaires showed statistically significant change for the BESAQ (p < 0.001 and the Body Esteem Scale (p < 0.001, but not for the Rosenberg Self-Esteem Scale (p > 0,05. A total of 15 patients (22.37% were dissatisfied about the prosthesis: the most frequent complaint (8 patients; 11.94% was that the prosthesis was firmer than the normal testis. Conclusions: Testicular prosthesis implantation is a safe surgical procedure that should be always proposed before orchiectomy for cancer of the testis. The defects complained by patients with testicular prosthesis are few, they don’t influence sexual activity and they aren’t able to cause erectile dysfunction or premature ejaculation.

  15. Candida infection of a prosthetic shoulder joint

    International Nuclear Information System (INIS)

    Lichtman, E.A.; Veterans Administration Medical Center, New York

    1983-01-01

    A heroin addict developed a Candida parapsilosis infection in a prosthetic shoulder joint. Radiographs showed loose fragments of cement with prosthetic loosening. The patient was treated with removal of the prosthesis and intravenous amphotericin B followed by oral ketoconazole. (orig.)

  16. A Mathematical Model for Temperature Induced Loosening due to Radial Expansion of Rectangle Thread Bolted Joints

    Directory of Open Access Journals (Sweden)

    Shiyuan Hou

    2015-01-01

    Full Text Available This paper proposed a mathematical model to investigate the radial expansion induced loosening of rectangle thread bolted joints that were subjected to cyclic temperature variation, which could cause slippage between contact pairs of engaged threads and bolt bearing. Firstly, integral equations were derived for the shear stress components caused by expansion difference, as well as the bearing and thread friction torque components, which depended on the temperature variation. Secondly, the relationship of displacement components was developed based on quasi-static hypotheses. Then, treating the rotation of bolt as plastic elongation, the bolt tension's evolution was obtained by using a one-dimensional bolted joint model. Numerical results showed that the temperature variation decreased the bearing and thread friction torque components, which could lead bolted joint to loosen. Finally, the effects of some associated factors on the progress were discussed.

  17. Use of Powered Prosthesis for Children with Upper Limb Deficiency at Hyogo Rehabilitation Center.

    Directory of Open Access Journals (Sweden)

    Mitsunori Toda

    Full Text Available There has been no research investigating the use of powered prosthetic for children in Japan.To gain better insight into the state of powered prosthesis usage and identify a ratio of rejection among children.Subjects were 37 unilateral below elbow amputees between the ages of 0 and 16 at the time of their first experienced fitting with a powered prosthesis at our Center. The information was collected from medical records and through face-to-face interviews, and we examined rejection rate and the factors affecting the use of powered prosthesis.The rate of discontinuation was 21.6% as 8 of the 37 children stopped using powered prosthesis. All of them were fitted their prosthesis after 2 years of age, and they rejected prosthesis between 5 to 19 years. We found that the level of amputation had no influence on the use of a powered prosthesis.Children fitted before 2 years of age tend to accept their powered prosthesis than those fitted after 2 years. Multidisciprinary team approach, adequate rehabilitation, detailed follow-up and involvement of parents are quite important for introducing powered prosthesis for children.

  18. Changes in performance over time while learning to use a myoelectric prosthesis

    NARCIS (Netherlands)

    Bouwsema, Hanneke; van der Sluis, Corry K.; Bongers, Raoul M.

    2014-01-01

    Background: Training increases the functional use of an upper limb prosthesis, but little is known about how people learn to use their prosthesis. The aim of this study was to describe the changes in performance with an upper limb myoelectric prosthesis during practice. The results provide a basis

  19. Design of a power-asymmetric actuator for a transtibial prosthesis.

    Science.gov (United States)

    Bartlett, Harrison L; Lawson, Brian E; Goldfarb, Michael

    2017-07-01

    This paper presents the design and characterization of a power-asymmetric actuator for a transtibial prosthesis. The device is designed to provide the combination of: 1) joint locking, 2) high power dissipation, and 3) low power generation. This actuator functionality allows for a prosthesis to be designed with minimal mass and power consumption relative to a fully-powered robotic prosthesis while maintaining much of the functionality necessary for activities of daily living. The actuator achieves these design characteristics while maintaining a small form factor by leveraging a combination of electromechanical and hydraulic components. The design of the actuator is described herein, and results of an experimental characterization are provided that indicate that the actuator is capable of providing the functional capabilities required of an ankle prosthesis in a compact and lightweight package.

  20. Ten-year in vivo wear measurement of a fully congruent mobile bearing unicompartmental knee arthroplasty.

    Science.gov (United States)

    Price, A J; Short, A; Kellett, C; Beard, D; Gill, H; Pandit, H; Dodd, C A F; Murray, D W

    2005-11-01

    Polyethylene particulate wear debris continues to be implicated in the aetiology of aseptic loosening following knee arthroplasty. The Oxford unicompartmental knee arthroplasty employs a spherical femoral component and a fully congruous meniscal bearing to increase contact area and theoretically reduce the potential for polyethylene wear. This study measures the in vivo ten-year linear wear of the device, using a roentgenstereophotogrammetric technique. In this in vivo study, seven medial Oxford unicompartmental prostheses, which had been implanted ten years previously were studied. Stereo pairs of radiographs were acquired for each patient and the films were analysed using a roentgen stereophotogrammetric analysis calibration and a computer-aided design model silhouette-fitting technique. Penetration of the femoral component into the original volume of the bearing was our estimate of linear wear. In addition, eight control patients were examined less than three weeks post-insertion of an Oxford prosthesis, where no wear would be expected. The control group showed no measured wear and suggested a system accuracy of 0.1 mm. At ten years, the mean linear wear rate was 0.02 mm/year. The results from this in vivo study confirm that the device has low ten-year linear wear in clinical practice. This may offer the device a survival advantage in the long term.

  1. Influence of recycling rate increase of aseptic carton for long-life milk on GWP reduction

    International Nuclear Information System (INIS)

    Mourad, Anna Lucia; Garcia, Eloisa E.C.; Vilela, Gustavo Braz; Von Zuben, Fernando

    2008-01-01

    Tetra Pak, through intensive cooperation with its supply chain, increased the post-consumer recycling rate of the aseptic packaging for long-life milk in the last 10 years. In continuation of a previous study that presented a superior overall performance in terms of reduction of the consumption of natural resources, air emissions and most of the water emissions, the objective of the present work was to apply life cycle assessment (LCA) to measure the global warming potential (GWP). The system was assessed using as functional unit 1000 liters of milk packaged in Tetra Pak Aseptic containers. The reduction of greenhouse gas emissions was calculated for recycling rates of 2%, 22%, 30%, 40% and 70% of the post-consumer residues in Scenarios I (only cardboard recycling) and II (total aseptic laminate recycling). Scenario I showed a 14% reduction in GWP, representing 26 kg of avoided CO 2 equiv. emitted due to the efforts of Tetra Pak to increase the recycling rate from 2% (2000) to 22% (2004). If it will be possible to increase the recycling rate to 70% of post-consumer packages in the future, a 48% reduction of GWP could be attained. Methane exhibited the greatest mass reduction among the greenhouse emissions, since it is emitted during the production of cardboard and also as a result of anaerobic degradation in landfills. The total reduction of the energy requirements of the system due to the increase of the recycling rate (from 2% to 22%) is 154 MJ/1000 liters, a saving of 7%. Scenario II (which considers additional polyethylene and aluminum recycling) has a smaller effect on GWP reduction than Scenario I, since PE/AL represent only 25% of the total mass of the container. The major benefit of the recycling of aseptic cartons is the reduction of the amounts of virgin materials required and the consequent reduction of air emissions. The results of this study can be used to encourage the collection of post-consumer milk cartons as part of environmental education

  2. Cranioplasty prosthesis manufacturing based on reverse engineering technology

    Science.gov (United States)

    Chrzan, Robert; Urbanik, Andrzej; Karbowski, Krzysztof; Moskała, Marek; Polak, Jarosław; Pyrich, Marek

    2012-01-01

    Summary Background Most patients with large focal skull bone loss after craniectomy are referred for cranioplasty. Reverse engineering is a technology which creates a computer-aided design (CAD) model of a real structure. Rapid prototyping is a technology which produces physical objects from virtual CAD models. The aim of this study was to assess the clinical usefulness of these technologies in cranioplasty prosthesis manufacturing. Material/Methods CT was performed on 19 patients with focal skull bone loss after craniectomy, using a dedicated protocol. A material model of skull deficit was produced using computer numerical control (CNC) milling, and individually pre-operatively adjusted polypropylene-polyester prosthesis was prepared. In a control group of 20 patients a prosthesis was manually adjusted to each patient by a neurosurgeon during surgery, without using CT-based reverse engineering/rapid prototyping. In each case, the prosthesis was implanted into the patient. The mean operating times in both groups were compared. Results In the group of patients with reverse engineering/rapid prototyping-based cranioplasty, the mean operating time was shorter (120.3 min) compared to that in the control group (136.5 min). The neurosurgeons found the new technology particularly useful in more complicated bone deficits with different curvatures in various planes. Conclusions Reverse engineering and rapid prototyping may reduce the time needed for cranioplasty neurosurgery and improve the prosthesis fitting. Such technologies may utilize data obtained by commonly used spiral CT scanners. The manufacturing of individually adjusted prostheses should be commonly used in patients planned for cranioplasty with synthetic material. PMID:22207125

  3. Legal, ethical, and procedural bases for the use of aseptic techniques to implant electronic devices

    Science.gov (United States)

    Mulcahy, Daniel M.

    2013-01-01

    animals often mask the signs of infection to avoid attracting predators (Wobeser 2006). Guidance specific to sterilization of electronic devices for implantation is limited in the wildlife record (Burger et al. 1994; Mulcahy 2003). Few biologists have been formally trained in aseptic technique, but most biologists know that electronic devices should be treated in some way to reduce the chance for infection of the host animal by bacteria, viruses, parasites, and fungi. Most biologists (73%) who implant devices into fishes believe aseptic techniques are important (Wagner and Cooke 2005). However, I maintain that many biologists find it difficult to place the concept of asepsis into practice in their work because of confusion about what constitutes aseptic technique, a lack of surgical knowledge and training, the perception of increased costs, or the belief that aseptic surgeries are impractical or unnecessary for their application. Some have even argued that, while compromising surgical techniques in the field might result in complications or mortalities, the money saved would allow for a compensatory increase in sample size (Anderson and Talcott 2006). In this paper I define aseptic surgical techniques, document the legal and professional guidance for performing aseptic surgeries on wild animals, and present options for sterilizing electronic devices and surgical instruments for field use.

  4. Function of obturator prosthesis after maxillectomy and prosthetic obturator rehabilitation.

    Science.gov (United States)

    Chen, Cheng; Ren, Wenhao; Gao, Ling; Cheng, Zheng; Zhang, Linmei; Li, Shaoming; Zhi, Pro Ke-qian

    2016-01-01

    Maxillary defects are usually rehabilitated by a prosthetic obturator. This study aimed to evaluate the functioning of obturators prosthesis in patients with unilateral defects after maxillectomy. Of 49 patients, 28 underwent to maxillectomy as a result of tumor ablative surgery, and acquired unilateral maxillary defects. Evaluation of the function was performed by applying the Obturator Functional Scale (OFS). From a total of 49 patients, 28 were treated as follows: 9 with a conventional retained obturator prosthesis (COP), 11 (39%) with an enhanced retentive obturator prosthesis with stud attachment (POP) and 8 (28%) with an enhanced retentive obturator prosthesis with magnetic attachment (POM). The mean OFS score was 80. Scores on functions of speech, swallowing and chewing reached statistical significances (p<0.05) among these three subgroups. Comparing COP and MOP groups, the scores of OFS in the domains of "Speech-ability to speak in public" and "Swallowing-leakage with liquids" were significantly higher in AOP group. Comparing COP group, the scores of OFS in "Swallowing-leakage with solid" and "Chewing/eating" domains were increased significantly (p<0.05) both in MOP and AOP groups. Obturator prosthesis improves oral function of patients after maxillary defects; the retention of the obturator prosthesis enhanced by the addition of attachments showed more benefits in oral function. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  5. Design and Characterization of a Quasi-Passive Pneumatic Foot-Ankle Prosthesis.

    Science.gov (United States)

    Lee, Jeffrey D; Mooney, Luke M; Rouse, Elliott J

    2017-07-01

    The majority of commercially available passive prosthetic feet are not capable of providing joint mechanics that match that of the intact human ankle. Due to their cantilever design, their stiffness characteristics contrast with what has been observed in the biological ankle, namely, an increase in stiffness during the stance phase of walking. In this paper, we introduce the design and control of a pneumatic foot-ankle prosthesis that attempts to provide biomimetic mechanics. The prosthesis is comprised of a pneumatic cylinder in series with a fiberglass leaf spring, and a solenoid valve to control the flow of air between the two sides of the cylinder. The solenoid valve acts as a mechanical clutch, enabling resetting of the ankle's equilibrium position. By adjusting the pressure inside the cylinder, the prosthesis can be customized to provide a range of ankle mechanics. A mechanical testing machine is used to compare the torque-angle curve of the pneumatic prosthesis with a low-profile passive prosthetic foot. Finally, data are presented of one transtibial amputee walking with the prosthesis at 1.2 m/s. The testing shows that the pneumatic prosthesis is capable of providing an appropriate range of motion as well a maximum torque of 94 Nm, while returning approximately 11.5 J of energy.

  6. Doppler derived gradient of ST Jude Mechanical Prosthesis, early postoperative assessment

    International Nuclear Information System (INIS)

    Shaikh, A.H.; Hanif, B.; Adil, A.; Hashimi, S.; Qazi, H.A.; Mujtaba, I.

    2010-01-01

    Objective: To determine the doppler derived mean gradients of St Jude mechanical prosthesis in early postoperative period in patients undergoing valve replacement at a tertiary care cardiac centre. Methods: Medical records of 190 consecutive patients who underwent 233 mitral, aortic or dual (mitral and aortic) valve replacement by St Jude bileaflet mechanical prosthesis at Tabba Heart Institute, between March 2006 to December 2008 were reviewed. Doppler derived mean gradients were assessed predischarge and recorded. Results: There were 98 (51.5%) males and 92 (48.5%) females in the study cohort. The mean age was 40 +- 14 years. Of the total, 101 (53%) had mitral, 46 (24.2%) had aortic and 43 (22.6%) patients had dual valve replacement. Doppler derived mean gradient was assessed across 144 mitral and 89 aortic St Jude mechanical prosthesis. Doppler derived mean gradient for St Jude mitral prosthesis was 3.5 mm Hg and for St Jude aortic prosthesis was 10.2 mm Hg. Conclusions: The study determines baseline gradients across mitral and aortic St Jude mechanical prosthesis in our population. These can be used as reference gradients to assess St Jude prosthetic valve function in patients who did not have early postoperative doppler assessment. (author)

  7. The reverse shoulder prosthesis: a review of imaging features and complications

    Energy Technology Data Exchange (ETDEWEB)

    McFarland, Edward G.; Sanguanjit, Prakasit; Tasaki, Atsushi [Johns Hopkins University, Department of Orthopedic Surgery, Lutherville, MD (United States); Keyurapan, Ekavit [Mahidol University, Department of Orthopaedic Surgery, Bangkok (Thailand); Fishman, Elliot K.; Fayad, Laura M. [Johns Hopkins Medical Institutions, Johns Hopkins University, Department of Radiology and Radiological Sciences, Baltimore, MD (United States)

    2006-07-15

    The reverse shoulder prosthesis is a prosthesis that has been in clinical use in Europe since 1985 and was approved for use in the United States in 2004. This unique prosthesis has a baseplate attached to the glenoid, which holds a spherical component, while the humeral component includes a polyethylene insert that is flat. This design is the ''reverse'' configuration of that seen with a conventional arthroplasty, in which the spherical component is part of the humeral component. The indications for the reverse prosthesis are: (1) painful arthritis associated with irreparable rotator cuff tears (cuff tear arthropathy), (2) failed hemiarthroplasty with irreparable rotator cuff tears, (3) pseudoparalysis due to massive, irreparable rotator cuff tears, (4) some reconstructions after tumor resection, and (5) some fractures of the shoulder not repairable or reconstructable with other techniques. This prosthesis can produce a significant reduction in pain and some improvement in function for most of the indications mentioned. However, the unique configuration and the challenge of its insertion can result in a high incidence of a wide variety of unusual complications. Some of these complications, such as dislocation of the components, are similar to conventional shoulder replacement. Other complications, such as notching of the scapula and acromial stress fractures, are unique to this prosthesis. (orig.)

  8. The reverse shoulder prosthesis: a review of imaging features and complications

    International Nuclear Information System (INIS)

    McFarland, Edward G.; Sanguanjit, Prakasit; Tasaki, Atsushi; Keyurapan, Ekavit; Fishman, Elliot K.; Fayad, Laura M.

    2006-01-01

    The reverse shoulder prosthesis is a prosthesis that has been in clinical use in Europe since 1985 and was approved for use in the United States in 2004. This unique prosthesis has a baseplate attached to the glenoid, which holds a spherical component, while the humeral component includes a polyethylene insert that is flat. This design is the ''reverse'' configuration of that seen with a conventional arthroplasty, in which the spherical component is part of the humeral component. The indications for the reverse prosthesis are: (1) painful arthritis associated with irreparable rotator cuff tears (cuff tear arthropathy), (2) failed hemiarthroplasty with irreparable rotator cuff tears, (3) pseudoparalysis due to massive, irreparable rotator cuff tears, (4) some reconstructions after tumor resection, and (5) some fractures of the shoulder not repairable or reconstructable with other techniques. This prosthesis can produce a significant reduction in pain and some improvement in function for most of the indications mentioned. However, the unique configuration and the challenge of its insertion can result in a high incidence of a wide variety of unusual complications. Some of these complications, such as dislocation of the components, are similar to conventional shoulder replacement. Other complications, such as notching of the scapula and acromial stress fractures, are unique to this prosthesis. (orig.)

  9. Association between dental prosthesis need, nutritional status and quality of life of elderly subjects

    DEFF Research Database (Denmark)

    Pillai, Rajath; Mathur, Vijay Prakash; Jain, Veena

    2015-01-01

    clinic were recruited in the study. Mini-nutritional assessment (MNA), geriatric oral health assessment (GOHAI) indices, prosthesis need according to WHO criteria, and prosthesis want was recorded along with age, gender, socioeconomic status and posterior occluding pair. RESULTS: Significant associations......To determine the effect of prosthesis need on nutritional status and oral health-related quality of life (OHrQoL) in elderly and to check the disparity between prosthesis need and prosthesis want in the Indian elderly. METHODS: A total of 946 geriatric participants reporting to a geriatric medicine...

  10. A Fuzzy Expert System for Distinguishing between Bacterial and Aseptic Meningitis

    Directory of Open Access Journals (Sweden)

    Mostafa Langarizadeh

    2015-05-01

    Full Text Available Introduction Bacterial meningitis is a known infectious disease which occurs at early ages and should be promptly diagnosed and treated. Bacterial and aseptic meningitis are hard to be distinguished. Therefore, physicians should be highly informed and experienced in this area. The main aim of this study was to suggest a system for distinguishing between bacterial and aseptic meningitis, using fuzzy logic.    Materials and Methods In the first step, proper attributes were selected using Weka 3.6.7 software. Six attributes were selected using Attribute Evaluator, InfoGainAttributeEval, and Ranker search method items. Then, a fuzzy inference engine was designed using MATLAB software, based on Mamdani’s fuzzy logic method with max-min composition, prod-probor, and centroid defuzzification. The rule base consisted of eight rules, based on the experience of three specialists and information extracted from textbooks. Results Data were extracted from 106 records of patients with meningitis (42 cases with bacterial meningitis in order to evaluate the proposed system. The system accuracy, specificity, and sensitivity were 89%, 92 %, and 97%, respectively. The area under the ROC curve was 0.93, and Kappa test revealed a good level of agreement (k=0.84, P

  11. CoCrMo alloy vs. UHMWPE Particulate Implant Debris Induces Sex Dependent Aseptic Osteolysis Responses In Vivo using a Murine Model

    Science.gov (United States)

    Landgraeber, Stefan; Samelko, Lauryn; McAllister, Kyron; Putz, Sebastian; Jacobs, Joshua.J.; Hallab, Nadim James

    2018-01-01

    Background: The rate of revision for some designs of total hip replacements due to idiopathic aseptic loosening has been reported as higher for women. However, whether this is environmental or inherently sex-related is not clear. Objective: Can particle induced osteolysis be sex dependent? And if so, is this dependent on the type of implant debris (e.g. metal vs polymer)? The objective of this study was to test for material dependent inflammatory osteolysis that may be linked to sex using CoCrMo and implant grade conventional polyethylene (UHMWPE), using an in vivo murine calvaria model. Methods: Healthy 12 week old female and male C57BL/6J mice were treated with UHMWPE (1.0um ECD) or CoCrMo particles (0.9um ECD) or received sham surgery. Bone resorption was assessed by micro-computed tomography, histology and histomorphometry on day 12 post challenge. Results: Female mice that received CoCrMo particles showed significantly more inflammatory osteolysis and bone destruction compared to the females who received UHMWPE implant debris. Moreover, females challenged with CoCrMo particles exhibited 120% more inflammatory bone loss compared to males (p<0.01) challenged with CoCrMo implant debris (but this was not the case for UHMWPE particles). Conclusion: We demonstrated sex-specific differences in the amount of osteolysis resulting from CoCrMo particle challenge. This suggests osteo-immune responses to metal debris are preferentially higher in female compared to male mice, and supports the contention that there may be inherent sex related susceptibility to some types of implant debris. PMID:29785221

  12. Smartphone supported upper limb prosthesis

    Directory of Open Access Journals (Sweden)

    Hepp D.

    2015-09-01

    Full Text Available State of the art upper limb prostheses offer up to six active DoFs (degrees of freedom and are controlled using different grip patterns. This low number of DoFs combined with a machine-human-interface which does not provide control over all DoFs separately result in a lack of usability for the patient. The aim of this novel upper limb prosthesis is both offering simplified control possibilities for changing grip patterns depending on the patients’ priorities and the improvement of grasp capability. Design development followed the design process requirements given by the European Medical Device Directive 93/42 ECC and was structured into the topics mechanics, software and drive technology. First user needs were identified by literature research and by patient feedback. Consequently, concepts were evaluated against technical and usability requirements. A first evaluation prototype with one active DoF per finger was manufactured. In a second step a test setup with two active DoF per finger was designed. The prototype is connected to an Android based smartphone application. Two main grip patterns can be preselected in the software application and afterwards changed and used by the EMG signal. Three different control algorithms can be selected: “all-day”, “fine” and “tired muscle”. Further parameters can be adjusted to customize the prosthesis to the patients’ needs. First patient feedback certified the prosthesis an improved level of handling compared to the existing devices. Using the two DoF test setup, the possibilities of finger control with a neural network are evaluated at the moment. In a first user feedback test, the smartphone based software application increased the device usability, e.g. the change within preselected grip patterns and the “tired muscle” algorithm. Although the overall software application was positively rated, the handling of the prosthesis itself needs to be proven within a patient study to be

  13. Effect of silicone gel breast prosthesis on electron and photon dose distributions

    International Nuclear Information System (INIS)

    Krishnan, L.; St George, F.J.; Mansfield, C.M.; Krishnan, E.C.

    1983-01-01

    The effect of a silicone gel breast prosthesis on the absorbed dose distribution of 9-20 MeV electron beams and 1.25-15 MV photon beams was studied. Compared to water measurements, at depths smaller than the practical range of the electron beams, the central axis depth dose values below the prosthesis were lower for all energies by as much as 3.5%. However, at depths near the practical range, the central axis depth dose values for the prosthesis were greater than that of water by as much as 33%. Since this occurs near the end of the electron range, the resultant difference may not be clinically significant. Results of the effect of breast prosthesis on photon depth dose distributions reveal that no clinically significant perturbation is produced by the breast prosthesis using Co-60, 6- and 15-MV radiations

  14. Fabrication of custom made ocular prosthesis with three different ...

    African Journals Online (AJOL)

    Loss of eye has a bad effect on the psychology of the patient. Eye prosthesis is fabricated to regain the patient's confidence by meticulous replacement of the missing eye. Immediate fitting of an anophthalmic socket with an artificial eye may not always be possible, and a delayed prosthesis delivery may result in settling and ...

  15. Simplified technique for orbital prosthesis fabrication: a clinical report.

    Science.gov (United States)

    Veerareddy, Chandrika; Nair, K Chandrasekharan; Reddy, G Ramaswamy

    2012-10-01

    Loss of orbital content can cause functional impairment, disfigurement of the face, and psychological distress. Rehabilitation of an orbital defect is a complex task, and if reconstruction by plastic surgery is not possible or not desired by the patient, the defect can be rehabilitated by an orbital prosthesis. The prosthetic rehabilitation in such cases depends on the precisely retained, user-friendly removable maxillofacial prosthesis. Many times, making an impression of the orbital area with an accurate record of surface details can be a difficult procedure. The critical areas are making a facial moulage, mold preparation, and attaching the retention device, particularly when eyeglass frames are used. This case focuses on these hindrance factors. A simple basket was used for the impression tray to obtain the facial moulage. A putty mold was used, and attachment of the prosthesis to a retention device was accomplished with positional distance. This method proves to be an economical and simple way of making an orbital prosthesis. © 2012 by the American College of Prosthodontists.

  16. [Rehabilitation by hollow obturator prosthesis immediately after total maxillectomy for malignant tumor].

    Science.gov (United States)

    Li, Xiao-ye; Yan, Ai-hui; Hao, Shuai; Li, Wei; Jiang, Xue-jun; Lu, Li; Qin, Xing-jun; Yan, Hai-xin

    2011-05-01

    The feasibility and clinical effects of hollow obturator prosthesis for the repair of maxillofacial defect immediately after maxillectomy for cancer were assessed. Thirteen patients with T3-4aN0M0 maxillary neoplasm were treated by the prostheses immediately after maxillectomy. According to the 3D-CT reconstruction of nasal sinus, the 3D stereoscopic prototype was constructed before the surgery. Simulating surgery with Surgicare 5.0 software and then the prosthesis 3D stereoscopic model was shaped. The prosthesis was made quickly and precisely with methacrylate resins according to the model and the print mold before surgery, with supplementary tooth at the bottom of prosthesis. In the surgery, the prosthesis was installed instantly after maxillectomy. The patients were followed up at 1, 3 and 6 month after the surgery, respectively. The facial features and the pronunciation clarity were examined and the questionnaires were carried out in the patients, with comparation by paired t-test. The hollow obturator prosthesis would be replaced by permanent prosthesis made of methacrylate resins at 6 month after the surgery. The hollow obturator prostheses were installed accurately and maxillofacial defects were repaired immediately after maxillectomy in the 13 patients. Postoperative follow-up showed there were significant differences in eyeball sagging (t = 4.67, P maxillectomy can improve survival quality of patient.

  17. Treatment of femoral neck fracture by Moore Prosthesis in Cotonou ...

    African Journals Online (AJOL)

    Treatment of femoral neck fracture by Moore Prosthesis in Cotonou. AHM Akue, M Lawson, S Madougou, R Zannou, J Padonou. Abstract. Keywords: Benin; hip; Moore prosthesis; results. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT.

  18. Analysis of the mechanical behavior of the Nijdam voice prosthesis

    NARCIS (Netherlands)

    Verkerke, GJ; deVries, MP; Schutte, HK; vandenHoogen, FJA; Rakhorst, G

    1997-01-01

    The valveless Nijdam prosthesis is a new voice prosthesis for laryngectomized patients using tracheoesophageal speech. An ''umbrella-like hat'' covers the esophageal side of the tracheoesophageal fistula and is deformed during speech by air pressure. To decrease pressure loss during speech, a good

  19. RSA prediction of high failure rate for the uncoated Interax TKA confirmed by meta-analysis.

    Science.gov (United States)

    Pijls, Bart G; Nieuwenhuijse, Marc J; Schoones, Jan W; Middeldorp, Saskia; Valstar, Edward R; Nelissen, Rob G H H

    2012-04-01

    In a previous radiostereometric (RSA) trial the uncoated, uncemented, Interax tibial components showed excessive migration within 2 years compared to HA-coated and cemented tibial components. It was predicted that this type of fixation would have a high failure rate. The purpose of this systematic review and meta-analysis was to investigate whether this RSA prediction was correct. We performed a systematic review and meta-analysis to determine the revision rate for aseptic loosening of the uncoated and cemented Interax tibial components. 3 studies were included, involving 349 Interax total knee arthroplasties (TKAs) for the comparison of uncoated and cemented fixation. There were 30 revisions: 27 uncoated and 3 cemented components. There was a 3-times higher revision rate for the uncoated Interax components than that for cemented Interax components (OR = 3; 95% CI: 1.4-7.2). This meta-analysis confirms the prediction of a previous RSA trial. The uncoated Interax components showed the highest migration and turned out to have the highest revision rate for aseptic loosening. RSA appears to enable efficient detection of an inferior design as early as 2 years postoperatively in a small group of patients.

  20. A systematic review and meta-regression of mobile-bearing versus fixed-bearing total knee replacement in 41 studies.

    Science.gov (United States)

    van der Voort, P; Pijls, B G; Nouta, K A; Valstar, E R; Jacobs, W C H; Nelissen, R G H H

    2013-09-01

    Mobile-bearing (MB) total knee replacement (TKR) was introduced to reduce the risk of aseptic loosening and wear of polyethylene inserts. However, no consistent clinical advantages of mobile- over fixed-bearing (FB) TKR have been found. In this study we evaluated whether mobile bearings have an advantage over fixed bearings with regard to revision rates and clinical outcome scores. Furthermore, we determined which modifying variables affected the outcome. A systematic search of the literature was conducted to collect clinical trials comparing MB and FB in primary TKR. The primary outcomes were revision rates for any reason, aseptic loosening and wear. Secondary outcomes included range of movement, Knee Society score (KSS), Oxford knee score (OKS), Short-Form 12 (SF-12) score and radiological parameters. Meta-regression techniques were used to explore factors modifying the observed effect. Our search yielded 1827 publications, of which 41 studies met our inclusion criteria, comprising over 6000 TKRs. Meta-analyses showed no clinically relevant differences in terms of revision rates, clinical outcome scores or patient-reported outcome measures between MB and FB TKRs. It appears that theoretical assumptions of superiority of MB over FB TKR are not borne out in clinical practice.

  1. Migration characteristics and early clinical results of the NANOS® short-stem hip arthroplasty.

    Science.gov (United States)

    Kaipel, Martin; Grabowiecki, Phillip; Sinz, Katrina; Farr, Sebastian; Sinz, Günter

    2015-05-01

    Femoral short stems promise essential advantages in total hip arthroplasty. Up to now, only short- and midterm clinical studies exist. Data on early stem migration that could predict later aseptic loosening at an early stage are rare. The purpose of this study was to assess migration patterns and clinical outcome 2 years after hip replacement by a metaphyseal anchored cementless short stem. Migration data and clinical results were prospectively assessed in 49 patients. Clinical outcome was measured using the Harris Hip Score (HHS). Migration analyses were performed using the computer-assisted Einzel-Bild-Roentgen-Analyse (EBRA) system. At 2 years after surgery, none of the implants needed revision, and HHS increased from 47.9 up to 98.1. Of 49 patients, 5 (10%) showed increased vertical stem migration (1.5 mm/2a) that might predict late aseptic loosening. Of 49 stems, 44 (90%) showed stable migration patterns indicating a beneficial long-term outcome. Results of this study confirm the excellent clinical data of previous works. Migration patterns strongly suggest that short-stem arthroplasty is not only an innovative but also a reliable strategy in total hip replacement.

  2. Custom-made silicone hand prosthesis: A case study.

    Science.gov (United States)

    Nayak, S; Lenka, P K; Equebal, A; Biswas, A

    2016-09-01

    Up to now, a cosmetic glove was the most common method for managing transmetacarpal (TMC) and carpometacarpal (CMC) amputations, but it is devoid of markings and body color. At this amputation level, it is very difficult to fit a functional prosthesis because of the short available length, unsightly shape, grafted skin, contracture and lack of functional prosthetic options. A 30-year-old male came to our clinic with amputation at the 1st to 4th carpometacarpal level and a 5th metacarpal that was projected laterally and fused with the carpal bone. The stump had grafted skin, redness, and an unhealed suture line. He complained of pain projected over the metacarpal and suture area. The clinical team members decided to fabricate a custom-made silicone hand prosthesis to accommodate the stump, protect the grafted skin, improve the hand's appearance and provide some passive function. The custom silicone hand prosthesis was fabricated with modified flexible wires to provide passive interphalangeal movement. Basic training, care and maintenance instructions for the prosthesis were given to the patient. The silicone hand prosthesis was able to restore the appearance of the lost digits and provide some passive function. His pain (VAS score) was reduced. Improvement in activities of daily living was found in the DASH questionnaire and Jebsen-Taylor Hand Function test. A silicone glove is a good option for more distal amputations, as it can accommodate any deformity, protect the skin, enhance the appearance and provide functional assistance. This case study provides a simple method to get passively movable fingers after proximal hand amputation. Copyright © 2016. Published by Elsevier Masson SAS.

  3. Mastication improvement after partial implant-supported prosthesis use.

    Science.gov (United States)

    Gonçalves, T M S V; Campos, C H; Gonçalves, G M; de Moraes, M; Rodrigues Garcia, R C M

    2013-12-01

    Partially edentulous patients may be rehabilitated by the placement of removable dental prostheses, implant-supported removable dental prostheses, or partial implant fixed dental prostheses. However, it is unclear the impact of each prosthesis type over the masticatory aspects, which represents the objective of this paired clinical trial. Twelve patients sequentially received and used each of these 3 prosthesis types for 2 months, after which maximum bite force was assessed by a strain sensor and food comminution index was determined with the sieving method. Masseter and temporal muscle thicknesses during rest and maximal clenching were also evaluated by ultrasonography. Each maxillary arch received a new complete denture that was used throughout the study. Data were analyzed by analysis of variance for repeated measures, followed by the Tukey test (p mastication, and the magnitude of this effect was related to prosthesis type.

  4. Ionizing radiations in aseptic bottling: a comparison between technologies and safety requirements [beverages

    International Nuclear Information System (INIS)

    Bottani, E.; Rizzo, R.; Vignali, G.

    2006-01-01

    Ionizing radiations, commonly adopted in the medical field, are recently experiencing a wide diffusion in industrials applications. One of the most widespread uses of ionizing radiations refers to foodstuffs and packaging sterilization. In the aseptic bottling area, the application of this technology on polymeric caps is quickly developing. In such application, sterilization could be obtained with beta-rays, generated by an electron beam, or with gamma-rays, emitted by a radioactive source. After a brief explanation of physical properties of ionizing radiations, the aim of this paper is to discuss the use of radiations in aseptic bottling. Based on results available in literature, radiations effects on treated materials are discussed, as well as safety requirements aiming at reducing risks related to radiation exposure. Finally, sterilization plants with gamma and beta radiation are compared, with the aim of examining functioning principles and management complexity. As a result of the comparison between the two technologies, the electron beam (beta-rays) adoption for caps sterilization process proves to be preferable [it

  5. Structural valve deterioration in the Mitroflow biological heart valve prosthesis

    DEFF Research Database (Denmark)

    Issa, Issa Farah; Poulsen, Steen Hvitfeldt; Waziri, Farhad

    2018-01-01

    OBJECTIVES: Concern has been raised regarding the long-term durability of the Mitroflow biological heart valve prosthesis. Our aim was to assess the incidence of structural valve degeneration (SVD) for the Mitroflow bioprosthesis in a nationwide study in Denmark including all patients alive......: A total of 173 patients were diagnosed with SVD by echocardiography. Of these, 64 (11%) patients had severe SVD and 109 (19%) patients moderate SVD. Severe SVD was associated with the age of the prosthesis and small prosthesis size [Size 21: hazard ratio (95% confidence interval, CI) 2.72 (0.97-8.56), P...

  6. Prosthesis infections after orthopedic joint replacement: the possible role of bacterial biofilms

    Directory of Open Access Journals (Sweden)

    Zhijun Song

    2013-06-01

    Full Text Available Prosthesis-related infection is a serious complication for patients after orthopedic joint replacement, which is currently difficult to treat with antibiotic therapy. Consequently, in most cases, removal of the infected prosthesis is the only solution to cure the infection. It is, therefore, important to understand the comprehensive interaction between the microbiological situation and the host immune responses that lead to prosthesis infections. Evidence indicates that prosthesis infections are actually biofilm-correlated infections that are highly resistant to antibiotic treatment and the host immune responses. The authors reviewed the related literature in the context of their clinical experience, and discussed the possible etiology and mechanism leading to the infections, especially problems related to bacterial biofilm, and prophylaxis and treatment of infection, including both microbiological and surgical measures. Recent progress in research into bacterial biofilm and possible future treatment options of prosthesis-related infections are discussed.

  7. Outcome of total knee arthroplasty with insall burstein-11 prosthesis

    International Nuclear Information System (INIS)

    Siddiq, M.Z.; Qayum, H.

    2006-01-01

    Patients with severe degenerative knee joint disease often require knee arthroplasty to reduce pain, improve stability and restore function. Insall Burstein II prosthesis is posteriorly stabilized condylar prosthesis, which provide posterior cruciate ligament substitution. It was designed to improve range of motion, stair climbing ability and to prevent posterior subluxation. Evaluate the functional outcome of total knee arthroplasty with IB II prosthesis and Evaluate the alignment of prosthetic components by radiological parameters and its correlation with functional outcome. Sixty knees of sixty patients were replaced by using Insall Burstein II prosthesis. Postoperative radiographs were evaluated for alignment of knee and prosthetic components by criteria selected from knee society roentogenographic evaluation system. Functional outcome was evaluated by rationale of knee society knee rating system. Prosthetic component was aligned in 93% and mal-alignment in 7% of the cases. There was significant improvement in functions core from mean score 33.83 +-15.5 to 59.5+-17.7 and knee score from 37 +- 12.5 to 76.4 +-2.2. Postoperative functional score was found correlated with alignment significantly. Conclusion: Total knee arthroplasty with I-B-II prosthesis is a safe durable and predictable procedure with proper surgical technique and expertise good alignment and satisfactory functional out come can be achieved. (author)

  8. Performance Analysis of Exam Gloves Used for Aseptic Rodent Surgery

    Science.gov (United States)

    LeMoine, Dana M; Bergdall, Valerie K; Freed, Carrie

    2015-01-01

    Aseptic technique includes the use of sterile surgical gloves for survival surgeries in rodents to minimize the incidence of infections. Exam gloves are much less expensive than are surgical gloves and may represent a cost-effective, readily available option for use in rodent surgery. This study examined the effectiveness of surface disinfection of exam gloves with 70% isopropyl alcohol or a solution of hydrogen peroxide and peracetic acid (HP–PA) in reducing bacterial contamination. Performance levels for asepsis were met when gloves were negative for bacterial contamination after surface disinfection and sham ‘exertion’ activity. According to these criteria, 94% of HP–PA-disinfected gloves passed, compared with 47% of alcohol-disinfected gloves. In addition, the effect of autoclaving on the integrity of exam gloves was examined, given that autoclaving is another readily available option for aseptic preparation. Performance criteria for glove integrity after autoclaving consisted of: the ability to don the gloves followed by successful simulation of wound closure and completion of stretch tests without tearing or observable defects. Using this criteria, 98% of autoclaved nitrile exam gloves and 76% of autoclaved latex exam gloves met performance expectations compared with the performance of standard surgical gloves (88% nitrile, 100% latex). The results of this study support the use of HP–PA-disinfected latex and nitrile exam gloves or autoclaved nitrile exam gloves as viable cost-effective alternatives to sterile surgical gloves for rodent surgeries. PMID:26045458

  9. Performance analysis of exam gloves used for aseptic rodent surgery.

    Science.gov (United States)

    LeMoine, Dana M; Bergdall, Valerie K; Freed, Carrie

    2015-05-01

    Aseptic technique includes the use of sterile surgical gloves for survival surgeries in rodents to minimize the incidence of infections. Exam gloves are much less expensive than are surgical gloves and may represent a cost-effective, readily available option for use in rodent surgery. This study examined the effectiveness of surface disinfection of exam gloves with 70% isopropyl alcohol or a solution of hydrogen peroxide and peracetic acid (HP-PA) in reducing bacterial contamination. Performance levels for asepsis were met when gloves were negative for bacterial contamination after surface disinfection and sham 'exertion' activity. According to these criteria, 94% of HP-PA-disinfected gloves passed, compared with 47% of alcohol-disinfected gloves. In addition, the effect of autoclaving on the integrity of exam gloves was examined, given that autoclaving is another readily available option for aseptic preparation. Performance criteria for glove integrity after autoclaving consisted of: the ability to don the gloves followed by successful simulation of wound closure and completion of stretch tests without tearing or observable defects. Using this criteria, 98% of autoclaved nitrile exam gloves and 76% of autoclaved latex exam gloves met performance expectations compared with the performance of standard surgical gloves (88% nitrile, 100% latex). The results of this study support the use of HP-PA-disinfected latex and nitrile exam gloves or autoclaved nitrile exam gloves as viable cost-effective alternatives to sterile surgical gloves for rodent surgeries.

  10. Prosthetic management of mid-facial defect with magnet-retained silicone prosthesis

    OpenAIRE

    Buzayan, M. M.

    2014-01-01

    Background and aim: Mid-facial defect is one of the most disfiguring and impairing defects. A design of prosthesis that is aesthetic and stable can be precious to a patient who has lost part of his face due to surgical excision. Prosthesis can restore the patients' self-esteem and confidence, which affects the patients and their life style. The aim of this case report is to describe a technique of mid-facial silicone prosthesis fabrication. Technique: To provide an aesthetic and stable facial...

  11. Acetabular prosthesis: Proff of migration with ruler and pencil?

    International Nuclear Information System (INIS)

    Diederichs, C.G.; Fischer, U.; Vosshenrich, R.

    1993-01-01

    Conventional X-ray films were made with varying degrees of tilt of a pelvic phantom containing an acetabular prosthesis. The position of the prosthesis was then reconstructed graphically. The measurement errors were calculated and an estimate was made for the tilt. There is a linear correlation between the measurement error and the tilt of the prosthesis. Therefore a tilt dependent maximum error can be calculated. This error is very small for small degrees of tilt, so that acetabular migration can in this instance be evaluated with greater confidence than with other graphical methods. The error also correlates with the determination of the selected region of the acetabulum, but not with the position of the central focus spot or image magnification. (orig.) [de

  12. [Imaging evaluation on adaptability of proximal humeral anatomy after shoulder replacement with individualized shoulder prosthesis].

    Science.gov (United States)

    Shi, Youxing; Tang, Kanglai; Yuan, Chengsong; Tao, Xu; Wang, Huaqing; Chen, Bo; Guo, Yupeng

    2015-03-24

    Modern shoulder prosthesis has evolved through four generations. And the fourth generation technology has a core three-dimensional design of restoring 3D reconstruction of proximal humeral anatomy. Thus a new shoulder prosthesis is developed on the basis of the technology of 3D prosthesis. Assessment of whether shoulder prosthesis can restore individualized reconstruction of proximal humeral anatomy is based on the adaptability of proximal humeral anatomy. To evaluate the adaptability of proximal humeral anatomy through measuring the parameters of proximal humeral anatomy after shoulder replacement with individualized shoulder prosthesis and compare with normal data. The parameters of proximal humeral anatomy were analyzed and evaluated for a total of 12 cases undergoing shoulder replacement with individualized shoulder prosthesis. The relevant anatomical parameters included neck-shaft angle (NSA), retroversion angle (RA), humeral head height (HH) and humeral head diameter (HD). And the anatomical parameters were compared with the data from normal side. All underwent shoulder replacement with individualized shoulder prosthesis. The postoperative parameters of proximal humeral anatomy were compared with those of normal side. And the difference of NSA was 0.05). Individualized shoulder prosthesis has excellent adaptability to shoulder. All core parameters are freely adjustable and specification models may be optimized. With matching tools, individualized shoulder prosthesis improves the accuracy and reliability in shoulder replacement.

  13. Schisantherin A suppresses osteoclast formation and wear particle-induced osteolysis via modulating RANKL signaling pathways

    Energy Technology Data Exchange (ETDEWEB)

    He, Yi; Zhang, Qing; Shen, Yi; Chen, Xia; Zhou, Feng; Peng, Dan, E-mail: xyeypd@163.com

    2014-07-04

    Highlights: • Schisantherin A suppresses osteoclasts formation and function in vitro. • Schisantherin A impairs RANKL signaling pathway. • Schisantherin A suppresses osteolysis in vivo. • Schisantherin A may be used for treating osteoclast related diseases. - Abstract: Receptor activator of NF-κB ligand (RANKL) plays critical role in osteoclastogenesis. Targeting RANKL signaling pathways has been a promising strategy for treating osteoclast related bone diseases such as osteoporosis and aseptic prosthetic loosening. Schisantherin A (SA), a dibenzocyclooctadiene lignan isolated from the fruit of Schisandra sphenanthera, has been used as an antitussive, tonic, and sedative agent, but its effect on osteoclasts has been hitherto unknown. In the present study, SA was found to inhibit RANKL-induced osteoclast formation and bone resorption. The osteoclastic specific marker genes induced by RANKL including c-Src, SA inhibited OSCAR, cathepsin K and TRAP in a dose dependent manner. Further signal transduction studies revealed that SA down-regulate RANKL-induced nuclear factor-kappaB (NF-κB) signaling activation by suppressing the phosphorylation and degradation of IκBα, and subsequently preventing the NF-κB transcriptional activity. Moreover, SA also decreased the RANKL-induced MAPKs signaling pathway, including JNK and ERK1/2 posphorylation while had no obvious effects on p38 activation. Finally, SA suppressed the NF-κB and MAPKs subsequent gene expression of NFATc1 and c-Fos. In vivo studies, SA inhibited osteoclast function and exhibited bone protection effect in wear-particle-induced bone erosion model. Taken together, SA could attenuate osteoclast formation and wear particle-induced osteolysis by mediating RANKL signaling pathways. These data indicated that SA is a promising therapeutic natural compound for the treatment of osteoclast-related prosthesis loosening.

  14. Rehabilitation of orbital cavity after orbital exenteration using polymethyl methacrylate orbital prosthesis

    Directory of Open Access Journals (Sweden)

    Sumeet Jain

    2016-01-01

    Full Text Available Squamous cell carcinoma of the eyelid is the second most common malignant neoplasm of the eye with the incidence of 0.09 and 2.42 cases/100 000 people. Orbital invasion is a rare complication but, if recognized early, can be treated effectively with exenteration. Although with advancements in technology such as computer-aided design and computer-aided manufacturing, material science, and retentive methods like implants, orbital prosthesis with stock ocular prosthesis made of methyl methacrylate retained by anatomic undercuts is quiet effective and should not be overlooked and forgotten. This clinical report describes prosthetic rehabilitation of two male patients with polymethyl methacrylate resin orbital prosthesis after orbital exenteration, for squamous cell carcinoma of the upper eyelid. The orbital prosthesis was sufficiently retained by hard and soft tissue undercuts without any complications. The patients using the prosthesis are quite satisfied with the cosmetic results and felt comfortable attending the social events.

  15. The risk of aseptic meningitis associated with the Leningrad-Zagreb mumps vaccine strain following mass vaccination with measles-mumps-rubella vaccine, Rio Grande do Sul, Brazil, 1997.

    Science.gov (United States)

    da Silveira, Claudio Marcos; Kmetzsch, Claudete Iris; Mohrdieck, Renate; Sperb, Alethea Fagundes; Prevots, D Rebecca

    2002-10-01

    Few data are available on the risk of aseptic meningitis following vaccination with the Leningrad-Zagreb (L-Z) strain of mumps vaccine. In 1997 the mumps vaccine was introduced into the state of Rio Grande do Sul in Brazil through mass vaccination with mumps-measles-rubella (MMR), targeting children aged 1-11 years. Five municipalities used exclusively MMR vaccine containing the L-Z strain of mumps. An outbreak of aseptic meningitis was observed shortly after the mass campaign. To estimate the risk of aseptic meningitis associated with this strain, we analysed vaccination and meningitis case surveillance data from the selected municipalities. A case of vaccine-associated aseptic meningitis was defined as one with a pleocytosis of 10-1,500 leukocytes/ml and occurring within 15-35 days after vaccine receipt. We estimated a risk of 2.9 cases per 10,000 doses of L-Z administered, equivalent to 1 case per 3,390 doses administered. The overall risk of aseptic meningitis following the campaign was increased 12.2-fold (95% CI: 6.0-24.7) compared with the same period in 1995-1996. Following the mass campaign, the incidence of mumps declined 93% during 1998-2000. Vaccination with the L-Z strain of mumps vaccine as part of a mass campaign was associated with a significantly increased risk of aseptic meningitis. Decisions about type of mumps vaccine and mumps vaccination strategies must consider vaccine safety issues in addition to other criteria.

  16. Prosthesis of the wrist-joint

    Energy Technology Data Exchange (ETDEWEB)

    Feldmeier, C.

    1983-02-25

    Function of the hand-joint and the well-being of patients can be severely affected by arthrosis of the wrist-joint. Therapeutically, arthrodesis usually results in a painfree status of stiffness. A painless and well functioning joint can be achieved by alloplastic joint replacement or resurfacing. The possibilities and clinical results in cases of arthrosis of the carpo-metacarpal joint of the thumb, pseudarthrosis of the scaphoid, aseptic necrosis of the Lunate and severe arthrosis of the radio-carpal joint are demonstrated.

  17. Multidisciplinary approach for in-deep assessment of joint prosthesis failure.

    Science.gov (United States)

    Tessarolo, F; Caola, I; Piccoli, F; Dorigotti, P; Demattè, E; Molinari, M; Malavolta, M; Barbareschi, M; Caciagli, P; Nollo, G

    2009-01-01

    In spite of advancement in biomaterials and biomechanics, in development of new osteo-integrative materials and coatings, and in macro- micro- component design, a non negligible fraction of the implanted prosthesis fails before the expected lifetime. A prospective observational clinical study has been conducted to define and apply a set of experimental techniques to in-deep assess the failure of joint prosthesis. Microbiological, histological and micro-structural techniques were implemented to specifically address phenomena occurring at the tissue-implant interface. Results obtained from 27 cases of prosthetic joint failure are discussed in terms of sensitivity and specificity. A procedural flow-chart is finally proposed for the assessment of joint prosthesis failure.

  18. Utilization of penile prosthesis and male incontinence prosthetics in Saudi Arabia.

    Science.gov (United States)

    Alwaal, Amjad; Al-Sayyad, Ahmad J

    2017-01-01

    Erectile dysfunction is a prevalent disease affecting over 50% of men between the ages of 40 and 70 years. Penile prosthesis represents the end of the line treatment when other less invasive therapies fail or are contraindicated. Male stress urinary incontinence can significantly diminish quality of life and lead to embarrassment and social withdrawal. Surgical therapies, such as male urethral slings and artificial urinary sphincters (AUS), are considered effective and safe treatments for male stress incontinence. No data exist on the utilization of penile prosthesis or male incontinence surgical treatment in Saudi Arabia. Generally, urological prosthetic surgery is performed either in private hospitals or in government hospitals. Our aim was to assess the trend of penile prosthesis and male incontinence device utilization in Saudi Arabia. We utilized sales' data of penile prosthetics, male slings, and AUS from the only two companies selling these devices in Saudi Arabia (AMS ® and Coloplast ® ), from January 2013 to December 2016. There were 2599 penile prosthesis implantation procedures done in the study period, with 67% of them performed in private institutions. There was a progressively increased use of penile prosthetics which nearly doubled from 2013 to 2016. The main type of prosthesis utilized was the semirigid type 70% versus 11% of the 2-piece inflatable and 17% of the 3-piece inflatable device. Only 10 slings and 31 AUS were inserted during the same study period. There is an increased utilization of penile prosthetics in Saudi Arabia. The private sector performs the majority of penile prosthesis procedures, and most of them are of the semirigid type. The governmental sector is more likely to perform inflatable penile prosthesis and male incontinence device procedures. Male incontinence prosthetics' use is very limited in Saudi Arabia.

  19. Preliminary and intermediate follow-up outcomes for cervical disc replacement in the treatment of cervical spondylopathy in 12 cases

    International Nuclear Information System (INIS)

    Qian Zhonglai; Yang Huilin; Jiang Weimin; Li Xigong; Li Xuefeng; Tang Tiansi

    2010-01-01

    Objective: To observe the short and intermediate-term clinical outcomes of porous coated motion (PCM) cervical prosthesis in the treatment of cervical spondylosis. Methods: The 12 (13 levels) patients who were suffered spondylotic myelopathy with PCM cervical prosthesis were treated. Evaluate the clinical outcome by comparing the JOA scores, the position of prosthesis,rotation of motion, the heterotopic ossification and Odom's scales. Results: After the average 6.5 months(3 ∼ 12 months) follow-up, the JOA scales raised from 8.35 ± 1.10 preoperatively to 15.88 ± 0.73 postoperatively (P 0.05). There was no occurrence of failures of prosthesis such as subsidence, loosening, or excursion. Heterotopic ossification was also absent. Conclusion: The clinical outcomes for cervical disc replacement in the treatment of cervical spondylopathy are satisfied. (authors)

  20. Total Ossicular Replacement Prosthesis: A New Fat Interposition Technique

    Directory of Open Access Journals (Sweden)

    Issam Saliba

    2018-01-01

    Full Text Available Objective: To compare audiometric results between the standard total ossicular replacement prosthesis (TORP-S and a new fat interposition total ossicular replacement prosthesis (TORP-F in pediatric and adult patients and to assess the complication and the undesirable outcome. Study design: This is a retrospective study. Methods: This study included 104 patients who had undergone titanium implants with TORP-F and 54 patients who had undergone the procedure with TORP-S between 2008 and 2013 in our tertiary care centers. The new technique consists of interposing a fat graft between the 4 legs of the universal titanium prosthesis (Medtronic Xomed Inc, Jacksonville, FL, USA to provide a more stable TORP in the ovale window niche. Normally, this prosthesis is designed to fit on the stapes’ head as a partial ossicular replacement prosthesis. Results: The postoperative air-bone gap less than 25 dB for the combined cohort was 69.2% and 41.7% for the TORP-F and the TORP-S groups, respectively. The mean follow-up was 17 months postoperatively. By stratifying data, the pediatric cohort shows 56.5% in the TORP-F group (n = 52 compared with 40% in the TORP-S group (n = 29. However, the adult cohort shows 79.3% in the TORP-F group (n = 52 compared with 43.75% in the TORP-S group (n = 25. These improvements in hearing were statistically significant. There were no statistically significant differences in the speech discrimination scores. The only undesirable outcome that was statistically different between the 2 groups was the prosthesis displacement: 7% in the TORP-F group compared with 19% in the TORP-S group ( P  = .03. Conclusions: The interposition of a fat graft between the legs of the titanium implants (TORP-F provides superior hearing results compared with a standard procedure (TORP-S in pediatric and adult populations because of its better stability in the oval window niche.

  1. Total Ossicular Replacement Prosthesis: A New Fat Interposition Technique.

    Science.gov (United States)

    Saliba, Issam; Sabbah, Valérie; Poirier, Jackie Bibeau

    2018-01-01

    To compare audiometric results between the standard total ossicular replacement prosthesis (TORP-S) and a new fat interposition total ossicular replacement prosthesis (TORP-F) in pediatric and adult patients and to assess the complication and the undesirable outcome. This is a retrospective study. This study included 104 patients who had undergone titanium implants with TORP-F and 54 patients who had undergone the procedure with TORP-S between 2008 and 2013 in our tertiary care centers. The new technique consists of interposing a fat graft between the 4 legs of the universal titanium prosthesis (Medtronic Xomed Inc, Jacksonville, FL, USA) to provide a more stable TORP in the ovale window niche. Normally, this prosthesis is designed to fit on the stapes' head as a partial ossicular replacement prosthesis. The postoperative air-bone gap less than 25 dB for the combined cohort was 69.2% and 41.7% for the TORP-F and the TORP-S groups, respectively. The mean follow-up was 17 months postoperatively. By stratifying data, the pediatric cohort shows 56.5% in the TORP-F group (n = 52) compared with 40% in the TORP-S group (n = 29). However, the adult cohort shows 79.3% in the TORP-F group (n = 52) compared with 43.75% in the TORP-S group (n = 25). These improvements in hearing were statistically significant. There were no statistically significant differences in the speech discrimination scores. The only undesirable outcome that was statistically different between the 2 groups was the prosthesis displacement: 7% in the TORP-F group compared with 19% in the TORP-S group ( P  = .03). The interposition of a fat graft between the legs of the titanium implants (TORP-F) provides superior hearing results compared with a standard procedure (TORP-S) in pediatric and adult populations because of its better stability in the oval window niche.

  2. Application of bone scintigrams in total knee replacement (Okayama MK-II type)

    Energy Technology Data Exchange (ETDEWEB)

    Umeda, T.; Inoue, S.; Matsui, N.; Moriya, H. (Chiba Univ. (Japan). School of Medicine)

    1982-02-01

    Eighteen patients with 21 total knee replacements (OKAYAMA MK-II type) were examined by radionuclide imaging in order to assess the prosthetic complaints such as loosening, infection, fracture and lasting pain. The following results and conclusions were obtained. 1) Bone imaging can reveal the condition of the attachment of bone and prosthesis. 2) Diffuse uptake gradually diminished until 18 months after surgery. 3) In front view on bone imaging, tibial uptake corresponded highly with the part of the weight area. 4) In cases of high uptake of posterior femoral component in lateral view, the range of knee flexion was mostly restricted. 5) Long-period persistent local uptake suggested loosening of the prosthesis or fracture of the tibial plateau. 6) Patello-femoral uptake showed no relation to the patellofemoral complaints. Radionuclide bone imaging is considered to represent one of the most valuable diagnostic procedures for assessing the clinical results after total knee replacement.

  3. Application of bone scintigrams in total knee replacement (Okayama MK-II type)

    International Nuclear Information System (INIS)

    Umeda, Tohru; Inoue, Shunichi; Matsui, Nobuo; Moriya, Hideshige

    1982-01-01

    Eighteen patients with 21 total knee replacements (OKAYAMA MK-II type) were examined by radionuclide imaging in order to assess the prosthetic complaints such as loosening, infection, fracture and lasting pain. The following results and conclusions were obtained. 1) Bone imaging can reveal the condition of the attachment of bone and prosthesis. 2) Diffuse uptake gradually diminished until 18 months after surgery. 3) In front view on bone imaging, tibial uptake corresponded highly with the part of the weight area. 4) In cases of high uptake of posterior femoral component in lateral view, the range of knee flexion was mostly restricted. 5) Long-period persistent local uptake suggested loosening of the prosthesis or fracture of the tibial plateau. 6) Patello-femoral uptake showed no relation to the patellofemoral complaints. Radionuclide bone imaging is considered to represent one of the most valuable diagnostic procedures for assessing the clinical results after total knee replacement. (author)

  4. Successful human infection with P. falciparum using three aseptic Anopheles stephensi mosquitoes: a new model for controlled human malaria infection.

    Directory of Open Access Journals (Sweden)

    Matthew B Laurens

    Full Text Available Controlled human malaria infection (CHMI is a powerful method for assessing the efficacy of anti-malaria vaccines and drugs targeting pre-erythrocytic and erythrocytic stages of the parasite. CHMI has heretofore required the bites of 5 Plasmodium falciparum (Pf sporozoite (SPZ-infected mosquitoes to reliably induce Pf malaria. We reported that CHMI using the bites of 3 PfSPZ-infected mosquitoes reared aseptically in compliance with current good manufacturing practices (cGMP was successful in 6 participants. Here, we report results from a subsequent CHMI study using 3 PfSPZ-infected mosquitoes reared aseptically to validate the initial clinical trial. We also compare results of safety, tolerability, and transmission dynamics in participants undergoing CHMI using 3 PfSPZ-infected mosquitoes reared aseptically to published studies of CHMI using 5 mosquitoes. Nineteen adults aged 18-40 years were bitten by 3 Anopheles stephensi mosquitoes infected with the chloroquine-sensitive NF54 strain of Pf. All 19 participants developed malaria (100%; 12 of 19 (63% on Day 11. The mean pre-patent period was 258.3 hours (range 210.5-333.8. The geometric mean parasitemia at first diagnosis by microscopy was 9.5 parasites/µL (range 2-44. Quantitative polymerase chain reaction (qPCR detected parasites an average of 79.8 hours (range 43.8-116.7 before microscopy. The mosquitoes had a geometric mean of 37,894 PfSPZ/mosquito (range 3,500-152,200. Exposure to the bites of 3 aseptically-raised, PfSPZ-infected mosquitoes is a safe, effective procedure for CHMI in malaria-naïve adults. The aseptic model should be considered as a new standard for CHMI trials in non-endemic areas. Microscopy is the gold standard used for the diagnosis of Pf malaria after CHMI, but qPCR identifies parasites earlier. If qPCR continues to be shown to be highly specific, and can be made to be practical, rapid, and standardized, it should be considered as an alternative for diagnosis

  5. Epidemiological and clinical studies on aseptic meningitis in 377 cases, 3

    International Nuclear Information System (INIS)

    Nishimura, Masaaki; Kondo, Tomio; Takashima, Akira; Kono, Shinya; Yamashina, Manabu

    1984-01-01

    Brain CT scan performed in the acute phase of aseptic meningitis in 88 cases revealed abnormal findings in 5 consisting of 2 of cerebral edema, 2 of subdural hygroma and one of cerebral atrophy. Clinical findings showed no particular relation to the age, but cerebral edema was observed in the cases of possible cephalomeningitis diagnosed on the basis of accompanying convulsion and disturbance of consciousness. Abnormal findings were associated with 25% of symptoms diagnosed more than 4 days after onset. (Chiba, N.)

  6. Percutaneous Revision of a Testicular Prosthesis is Safe, Cost-effective, and Provides Good Patient Satisfaction

    Directory of Open Access Journals (Sweden)

    Eugene B. Cone

    2015-09-01

    Full Text Available Office-based percutaneous revision of a testicular prosthesis has never been reported. A patient received a testicular prosthesis but was dissatisfied with the firmness of the implant. In an office setting, the prosthesis was inflated with additional fluid via a percutaneous approach. Evaluated outcomes included patient satisfaction, prosthesis size, recovery time, and cost savings. The patient was satisfied, with no infection, leak, or complication after more than 1 year of follow-up, at significantly less cost than revision surgery. Percutaneous adjustment of testicular prosthesis fill-volume can be safe, inexpensive, and result in good patient satisfaction.

  7. [Validation of a clinical prediction rule to distinguish bacterial from aseptic meningitis].

    Science.gov (United States)

    Agüero, Gonzalo; Davenport, María C; Del Valle, María de la P; Gallegos, Paulina; Kannemann, Ana L; Bokser, Vivian; Ferrero, Fernando

    2010-02-01

    Despite most meningitis are not bacterial, antibiotics are usually administered on admission because bacterial meningitis is difficult to be rule-out. Distinguishing bacterial from aseptic meningitis on admission could avoid inappropriate antibiotic use and hospitalization. We aimed to validate a clinical prediction rule to distinguish bacterial from aseptic meningitis in children, on arriving to the emergency room. This prospective study included patients aged or = 1000 cells/mm(3), CSF protein > or = 80 mg/dl, peripheral blood absolute neutrophil count > or = 10.000/mm(3), seizure = 1 point each. Sensitivity (S), specificity (E), positive and negative predictive values (PPV and NPV), positive and negative likelihood ratios (PLR and NLR) of the BMS to predict bacterial meningitis were calculated. Seventy patients with meningitis were included (14 bacterial meningitis). When BMS was calculated, 25 patients showed a BMS= 0 points, 11 BMS= 1 point, and 34 BMS > or = 2 points. A BMS = 0 showed S: 100%, E: 44%, VPP: 31%, VPN: 100%, RVP: 1,81 RVN: 0. A BMS > or = 2 predicted bacterial meningitis with S: 100%, E: 64%, VPP: 41%, VPN: 100%, PLR: 2.8, NLR:0. Using BMS was simple, and allowed identifying children with very low risk of bacterial meningitis. It could be a useful tool to assist clinical decision making.

  8. A direct bonded fixed partial dental prosthesis: A clinical report

    OpenAIRE

    Tanoue, Naomi; Tanaka, Takuo

    2015-01-01

    A direct bonded fixed partial dental prosthesis, with a composite resin denture tooth as a pontic, a tri-n-butylborane initiated adhesive resin, and screw posts for reinforcement, was still functioning after an observation period of 20 years. The prosthesis was found to be reliable for long-term clinical use when chemically and mechanically reinforced.

  9. Prosthesis of the wrist-joint

    International Nuclear Information System (INIS)

    Feldmeier, C.

    1983-01-01

    Function of the hand-joint and the well-being of patients can be severely affected by arthrosis of the wrist-joint. Therapeutically, arthrodesis usually results in a painfree status of stiffness. A painless and well functioning joint can be achieved by alloplastic joint replacement or resurfacing. The possibilities and clinical results in cases of arthrosis of the carpo-metacarpal joint of the thumb, pseudarthrosis of the scaphoid, aseptic necrosis of the Lunate and severe arthrosis of the radio-carpal joint are demonstrated. (orig.) [de

  10. Rehabilitation of single finger amputation with customized silicone prosthesis

    OpenAIRE

    Yadav, Niharika; Chand, Pooran; Jurel, Sunit Kumar

    2016-01-01

    Finger amputations are common in accidents at home, work, and play. Apart from trauma, congenital disease and deformity also leads to finger amputation. This results in loss of function, loss of sensation as well as loss of body image. Finger prosthesis offers psychological support and social acceptance in such cases. This clinical report describes a method to fabricate ring retained silicone finger prosthesis in a patient with partial finger loss.

  11. Dose distribution perturbation due to a Co-Cr-Mo prosthesis

    International Nuclear Information System (INIS)

    Castro Novais, J.; Rodriguez Rodriguez, C.; Cabello Murillo, E.; Fernandez Leton, P.; Perez Moreno, J. M.; Lopez Fernandez, A.; Ferrando Sanchez, A.; Martinez Gomez, L. C.

    2009-01-01

    Knowledge of the attenuation and interface effects when irradiating metallic prosthesis is necessary for the radiotherapy treatment of patients with this kind of implants. This report studies the dose distribution of a 6 MV photon beam in the vicinity of a 1,5 cm diameter Co-Cr-Mo prosthesis. Measurements with Gafchromic EBT radiochromic films have been made. Two blocks of cut films have been placed next to the prosthesis, one in each side. Forty two films reaching a height of 1 cm have been piled up in each block. A spatial resolution equal to the thickness of one film (0,24 mm) is achieved. The results show 28% attenuation and the production of a 42% overdose at the entrance interface, 12% and 3% at 1 mm and 2 mm away from the prosthesis respectively. A 5 mm build-up region is originated in the exit interface, where the under dose is less than 10%. The knowledge of the transmission factor and the interface effects allows us to assess the dose calculated by the treatment planning system. (Author) 11 refs.

  12. Referral of sensation to an advanced humanoid robotic hand prosthesis.

    Science.gov (United States)

    Rosén, Birgitta; Ehrsson, H Henrik; Antfolk, Christian; Cipriani, Christian; Sebelius, Fredrik; Lundborg, Göran

    2009-01-01

    Hand prostheses that are currently available on the market are used by amputees to only a limited extent, partly because of lack of sensory feedback from the artificial hand. We report a pilot study that showed how amputees can experience a robot-like advanced hand prosthesis as part of their own body. We induced a perceptual illusion by which touch applied to the stump of the arm was experienced from the artificial hand. This illusion was elicited by applying synchronous tactile stimulation to the hidden amputation stump and the robotic hand prosthesis in full view. In five people who had had upper limb amputations this stimulation caused referral touch sensation from the stump to the artificial hand, and the prosthesis was experienced more like a real hand. We also showed that this illusion can work when the amputee controls the movements of the artificial hand by recordings of the arm muscle activity with electromyograms. These observations indicate that the previously described "rubber hand illusion" is also valid for an advanced hand prosthesis, even when it has a robotic-like appearance.

  13. Adhesive strength of hydroxyl apatite(HA coating and biomechanics behavior of HA-coated prosthesis:an experimental study

    Directory of Open Access Journals (Sweden)

    Tian-yang ZHANG

    2011-05-01

    Full Text Available Objective To explore the influence of adhesive strength of hydroxyapatite(HA coating on the post-implantation stability of HA-coated prosthesis.Methods The adhesive strength and biomechanics behavior of HA coating were studied by histopathological observation,material parameters and biomechanical testing,the titanium(Ti-coated prosthesis was employed as control.Results Scratch test showed that the adhesive strength of HA coating was significantly lower than that of Ti coating(P < 0.01.Histopathological examination and bone morphometry showed that,at the early stage of prosthesis implantation,the bony growth around HA-coated prosthesis was significantly higher than that around Ti-coated prosthesis(P < 0.01,but the ultimate shear strength of HA-coated prosthesis was much lower than that of Ti-coated prosthesis(P < 0.01.After the push-out test with prosthesis,histopathological observation showed that there were accumulations of clump-and strip-like granular residues on the surface of bones that newly grew around the HA-coated prosthesis,and surface energy-dispersive X-ray spectroscopy(EDX analysis also confirmed that the shear stress induced HA decohesion from the substrate of prosthesis.Conclusions Although HA coating showed a satisfactory effect on early bone formation and prosthetic stability,due to the deficiencies of adhesive strength,the early stability of prosthesis may be gradually destroyed by the shear loads of human body and coating degradation.

  14. Advanced engineering tools for design and fabrication of a custom nasal prosthesis

    Science.gov (United States)

    Oliveira, Inês; Leal, Nuno; Silva, Pedro; da Costa Ferreira, A.; Neto, Rui J.; Lino, F. Jorge; Reis, Ana

    2012-09-01

    Unexpected external defects resulting from neoplasms, burns, congenital malformations, trauma or other diseases, particularly when involving partial or total loss of an external organ, can be emotionally devastating. These defects can be restored with prosthesis, obtained by different techniques, materials and methods. The increase of patient numbers and cost constraints lead to the need of exploring new techniques that can increase efficiency. The main goal of this project was to develop a full engineering-based manufacturing process to obtain soft-tissue prosthesis that could provide faster and less expensive options in the manufacturing of customized prosthesis, and at the same time being able to reproduce the highest degree of details, with the maximum comfort for the patient. Design/methodology/approach - This case report describes treatment using silicone prosthesis with an anatomic retention for an 80-years-old woman with a rhinectomy. The proposed methodology integrates non-contact structured light scanning, CT and reverse engineering with CAD/CAM and additive manufacturing technology. Findings - The proposed protocol showed encouraging results since reveals being a better solution for fabricating custom-made facial prostheses for asymmetrical organs than conventional approaches. The process allows the attainment of prosthesis with the minimum contact and discomfort for the patient, disclosing excellent results in terms of aesthetic, prosthesis retention and in terms of time and resources consumed.

  15. The method of manufacture of nylon dental partially removable prosthesis using additive technologies

    Science.gov (United States)

    Kashapov, R. N.; Korobkina, A. I.; Platonov, E. V.; Saleeva, G. T.

    2014-12-01

    The article is devoted to the topic of creating new methods of dental prosthesis. The aim of this work is to investigate the possibility of using additive technology to create nylon prosthesis. As a result of experimental studies, was made a sample of nylon partially removable prosthesis using 3D printing has allowed to simplify, accelerate and reduce the coat of manufacturing high-precision nylon dentures.

  16. 21 CFR 874.3540 - Prosthesis modification instrument for ossicular replacement surgery.

    Science.gov (United States)

    2010-04-01

    ... replacement surgery. 874.3540 Section 874.3540 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... § 874.3540 Prosthesis modification instrument for ossicular replacement surgery. (a) Identification. A prosthesis modification instrument for ossicular replacement surgery is a device intended for use by a...

  17. Predictors of Receiving a Prosthesis for Adults With Above-Knee Amputations in a Well-Defined Population.

    Science.gov (United States)

    Mundell, Benjamin F; Kremers, Hilal Maradit; Visscher, Sue; Hoppe, Kurtis M; Kaufman, Kenton R

    2016-08-01

    Prior studies have identified age as a factor in determining an individual's likelihood of receiving a prosthesis following a lower limb amputation. These studies are limited to specific subsets of the general population and are unable to account for preamputation characteristics within their study populations. Our study seeks to determine the effect of preamputation characteristics on the probability of receiving a prosthesis for the general population in the United States. To identify preamputation characteristics that predict of the likelihood of receiving a prosthesis following an above-knee amputation. A retrospective, population-based cohort study. Olmsted County, Minnesota (2010 population: 144,248). Individuals (n = 93) over the age of 18 years who underwent an above-knee amputation, that is, knee disarticulation or transfemoral amputation, while residing in Olmsted County, MN, between 1987 and 2013. Characteristics affecting the receipt of a prosthesis were analyzed using a logistic regression and a random forest algorithm for classification trees. Preamputation characteristics included age, gender, amputation etiology, year of amputation, mobility, cognitive ability, comorbidities, and time between surgery and the prosthesis decision. The association of preamputation characteristics with the receipt of a prosthesis following an above-knee amputation. Twenty-four of the participants received a prosthesis. The odds of receiving a prosthesis were almost 30 times higher in those able to walk independently prior to an amputation relative to those who could not walk independently. A 10-year increase in age was associated with a 53.8% decrease in the likelihood of being fit for a prosthesis (odds ratio = 0.462, P =.030). Time elapsed between surgery and the prosthesis decision was associated with a rise in probability of receiving a prosthesis for the first 3 months in the random forest algorithm. No other observed characteristics were associated with receipt

  18. Strategy to avoid patient-prosthesis mismatch: aortic root enlargement.

    Science.gov (United States)

    Srivastava, Dharmendra Kumar; Sanki, Prokash; Bhattacharya, Subhankar; Siddique, Javed Veqar

    2014-02-01

    The choice of a valve with an effective orifice area matching the body surface area and providing efficient hemodynamics is an important factor affecting mortality and morbidity in patients undergoing aortic valve replacement. Our preventative strategy was to implant a larger prosthetic valve by aortic root enlargement using the Nunez procedure in 17 patients between February 2010 and January 2011. The decision to enlarge the aortic root was taken when the 19-mm sizer could not be negotiated easily through the aortic root, or on the basis of body surface area of the patient or type of prosthesis available. Postoperative reductions in peak and mean pressure gradients across aortic valve of 12.8-16.5 and 10.2-12.6 mm Hg, respectively, were observed. Postoperative effective orifice areas of the aortic valves were 1.1-1.5 cm(2). By upsizing the aortic valve, we were able to eliminate patient-prosthesis mismatch in 5 patients, and reduce severe patient-prosthesis mismatch to moderate in 11. Aortic root enlargement is a safe procedure. Therefore, cardiac surgeons should not be reluctant to enlarge the aortic root with an autologous pericardial patch to permit implantation of an adequate size of aortic valve prosthesis, with minimal additional aortic crossclamp time and no added cost.

  19. Smart image processing system for retinal prosthesis.

    Science.gov (United States)

    Weiland, James D; Parikh, Neha; Pradeep, Vivek; Medioni, Gerard

    2012-01-01

    Retinal prostheses for the blind have demonstrated the ability to provide the sensation of light in otherwise blind individuals. However, visual task performance in these patients remains poor relative to someone with normal vision. Computer vision algorithms for navigation and object detection were evaluated for their ability to improve task performance. Blind subjects navigating a mobility course had fewer collisions when using a wearable camera system that guided them on a safe path. Subjects using a retinal prosthesis simulator could locate objects more quickly when an object detection algorithm assisted them. Computer vision algorithms can assist retinal prosthesis patients and low-vision patients in general.

  20. [Lessons from a heart valve prosthesis controversy].

    Science.gov (United States)

    Vandenbroucke, J P; Grobbee, D E

    1998-07-18

    Two lessons are to be learnt from the Björk-Shiley heart valve prosthesis tragedy. In the first place pharmacoepidemiologic studies are seriously hampered by recent privacy legislation. Individual patients carrying such a prosthesis cannot be traced and advised as to their health risks any more, because their legal autonomy has to be respected. This is clearly not to their advantage. In the second place the atmosphere of marketing and litigation and the increasing dependency of researchers on money from sources with conflicting interests is not conducive to a well-informed and balanced judgement of the epidemiological evidence of safety and efficacy of medical treatments.

  1. Combined nuclear and digital subtraction contrast arthrography in painful knee prosthesis

    International Nuclear Information System (INIS)

    Namasivayam, J.; Forrester, A.; Poon, F.W.; Cuthbert, G.F.; McKillop, J.H.; Bryan, A.S.

    1992-01-01

    The evaluation of a painful knee prosthesis remains a difficult problem for both orthopaedic surgeons and radiologists. We have compared digital subtraction arthrography with nuclear-arthrography in 7 patients with a painful knee prosthesis. Three patients showed a loose tibial component, demonstrated by both digital subtraction and nuclear arthrography. All 3 underwent revision of their prosthesis. One patient had an equivocal digital subtraction arthrogram and negative nuclear arthrogram, while both studies were negative in the 3 remaining patients. Nuclear arthrography is a simple procedure and can provide useful additional information when combined with digital subtraction arthrography. (orig.)

  2. Isolation and characterization of beta-glucan synthase: A potential biochemical regulator of gravistimulated differential cell wall loosening

    Science.gov (United States)

    Kuzmanoff, K. M.

    1984-01-01

    In plants, gravity stimulates differential growth in the upper and lower halves of horizontally oriented organs. Auxin regulation of cell wall loosening and elongation is the basis for most models of this phenomenon. Auxin treatment of pea stem tissue rapidly increases the activity of Golgi-localized Beta-1,4-glucan synthase, an enzyme involved in biosynthesis of wall xyloglucan which apparently constitutes the substrate for the wall loosening process. The primary objective is to determine if auxin induces de novo formation of Golgi glucan synthase and increases the level of this glucan synthase mRNA. This shall be accomplished by (a) preparation of a monoclonal antibody to the synthase, (b) isolation, and characterization of the glucan synthase, and (c) examination for cross reactivity between the antibody and translation products of auxin induced mRNAs in pea tissue. The antibody will also be used to localize the glucan synthase in upper and lower halves of pea stem tissue before, during and after the response to gravity.

  3. 21 CFR 878.3720 - Tracheal prosthesis.

    Science.gov (United States)

    2010-04-01

    ...) Identification. The tracheal prosthesis is a rigid, flexible, or expandable tubular device made of a silicone... of the trachea or trachealbronchial tree. It may be unbranched or contain one or two branches. The...

  4. Aseptic necrosis of the femoral head after pregnancy: a case report.

    Science.gov (United States)

    Nassar, Kawtar; Rachidi, Wafae; Janani, Saadia; Mkinsi, Ouafa

    2016-01-01

    A documented case of beginning aseptic necrosis of the femoral head associated with pregnancy together with a review of the literature about this rare complication of pregnancy is presented. The known risk factors of osteonecrosis are; steroid use, alcoholism, organ transplantation, especially after kidney transplant or bone marrow transplantation bone, systemic lupus erythematosus, dyslipidemia especially hypertriglyceridemia, dysbaric decompression sickness, drepanocytosis and Gaucher's disease. Among the less established factors, we mention procoagulations abnormalities, HIV infection, chemotherapy. We report a case of osteonecrosis of femoral head after pregnancy.

  5. Magnetically retained silicone facial prosthesis

    African Journals Online (AJOL)

    2013-06-09

    Jun 9, 2013 ... Prosthetic camouflaging of facial defects and use of silicone maxillofacial material are the alternatives to the surgical retreatment. Silicone elastomers provide more options to clinician for customization of the facial prosthesis which is simple, esthetically good when coupled with bio magnets for retention.

  6. Pattern of External Breast Prosthesis Use by Post Mastectomy Breast Cancer Patients in India: Descriptive Study from Tertiary Care Centre.

    Science.gov (United States)

    Ramu, D; Ramesh, Rakesh S; Manjunath, Suraj; Shivakumar; Goel, Vipin; Hemnath, G N; Alexander, Annie

    2015-12-01

    In India, Breast cancer is now the most common cancer in urban and 2nd most common in rural areas [1]. The incidence is rising, more younger women are getting affected and due to increase in survival rates there is an increase in the total number of women suffering from breast Cancer. So far there are no studies evaluating the pattern of breast prosthesis use in Indian scenario. The aim of this study is to address the patterns of external breast prosthesis used in India and view of Indian women on such prosthesis after mastectomy for breast cancer. This was a descriptive longitudinal study. In this study we interviewed (telephonic) 63 people, after three years of completing treatment under The Department of Surgical Oncology, St. Johns medical college, Bangalore. Among the study group, 27 members (40 %) were using various prosthesis, rest 36 women were not using any type of prosthesis. Among the users of prosthesis, silicon prosthesis was used by 6 women, padded cups by 8 women, cloth or cotton by 12 women and 1 woman used other type of prosthesis. Most women use simple items like cloth and cotton (44 %). Next most commonly used prosthesis are padded cups(). Only 22 % of women were found using silicon prosthesis in this study. Most of the well educated patients used external prosthesis either in the form of silicon prosthesis or padded cups. Most of women below age of 50 used external breast prosthesis. Use of prosthesis was more in urban compared to rural population (48 % vs 25 %). Prosthesis users worried more about the body image than women not using prosthesis. 25 % of women using prosthesis had body image issues where as only 5 % of non prosthesis users had such problems. Prosthesis users need improvement in terms of comfort, size, shape and affordability. Most common reasons for not using prosthesis are age, lack of motivation and awareness. Less than half of the women included in this study used external prosthesis after mastectomy for breast cancer

  7. Radiological evaluation of failed total hip replacement

    International Nuclear Information System (INIS)

    Raspa, V.; Aldrovandi, S.; Pompei, G.

    1988-01-01

    The retrospective study of 50 operated cases of cemented total hip replacement and a review of the literature enabled the authors to define the radiological features of the above-mentioned condition. These features include one or more of the following signs: calcar reabsorption, lacunar erosions, modified relatioships between the prosthesis components, sepsis and loosening, periarticular calcifications dislocation and fracture of prosthesis components. Careful evaluation of these radiological features is extremely important for both an early diagnosis of failed total hip replacement and the choice of an adequate surgical treatment

  8. Candida albicans, Staphylococcus aureus and Streptococcus mutans colonization in patients wearing dental prosthesis.

    Science.gov (United States)

    Baena-Monroy, Tania; Moreno-Maldonado, Víctor; Franco-Martínez, Fernando; Aldape-Barrios, Beatriz; Quindós, Guillermo; Sánchez-Vargas, Luis Octavio

    2005-04-01

    Denture stomatitis is associated to Candida albicans, different bacteria and other co-factors such as an acid pH, a carbohydrate ingestion increase, different systemic illnesses and pharmacological treatments. The aim of this study was to determine Candida albicans, Staphylococcus aureus and Streptococcus mutans prevalence in the mucous membrane and prosthesis of patients with and without atrophic denture stomatitis and its relationship with other potential clinical co-factors. Saliva was collected from 105 patients (62 female and 43 male) wearing dental prosthesis in order to measure their pH. Oral samples of the mucous membrane and the internal surface of dental prosthesis were taken with sterile cotton to proceed with the microbiological study. The identification of the isolated microorganisms was performed using conventional microbiological methods. Diabetes and Hypertension were the most frequent systemic illnesses. High carbohydrate ingestion was observed in numerous patients. Atrophic denture stomatitis was reported in 50 patients and the pH average in saliva was of 5.2. The presence of C albicans, S. aureus and S. mutans in the mucous membrane and prosthesis was of 51.4%, 52.4% and 67.6%, respectively. C. albicans was isolated in 66.7% from the prosthesis, whereas S. aureus and S. mutans were isolated in 49.5% of those same prosthesis. C. albicans was isolated in 86% of the patients with atrophic denture stomatitis and S. aureus was isolated in a similar percentage (84% of patients). The isolation of S. mutans was less frequent, and it was observed in 16% of the oral samples of these patients. C. albicans, S. aureus and S. mutans frequently colonize the oral mucous of patients wearing dental prosthesis. This illness-bearing condition is more frequent in patients with denture stomatitis, even though dental prosthesis colonization is lower than in the oral mucous.

  9. Survival of various implant-supported prosthesis designs following 36 months of clinical function.

    Science.gov (United States)

    Rodriguez, A M; Orenstein, I H; Morris, H F; Ochi, S

    2000-12-01

    The use of endosseous dental implants to replace natural teeth lost to trauma, dental caries, or periodontal disease has become a predictable form of prosthetic treatment since gaining popularity in the early 1980s. While numerous clinical studies have focused on the survival of implants, few address the survival of different prosthesis designs. Beginning in 1991, 882 prostheses supported by more than 2,900 implants (687 patients) were placed by the Department of Veterans Affairs Dental Implant Clinical Research Group (DICRG). These prostheses were divided into five research strata based on arch location. The recommended design for each stratum was: bar-supported overdenture (maxillary completely edentulous); screw-retained hybrid denture (mandibular completely edentulous); screw-retained fixed partial denture (mandibular and maxillary posterior partially edentulous); and cemented single crown (maxillary anterior single tooth). Alternative overdenture designs were utilized in the edentulous arches when the recommended prosthesis could not be fabricated. Prosthesis success rates for the research strata were calculated for an observation time of up to 36 months following prosthesis placement. Success rates for the maxillary edentulous stratum ranged from 94.6% for the bar-retained overdenture supported by five to six fixtures to 81.8% for the cap-retained overdenture. The mandibular edentulous strata produced success rates of 98.1% for the fixed hybrid prosthesis to 91.7% for the cap-retained prosthesis. Success rates for maxillary and mandibular posterior fixed partial dentures were 94.3% and 92.6%, respectively, while the maxillary anterior single-tooth prosthesis yielded a success rate of 98.1% for the 36-month observation period. The recommended prosthesis designs investigated in this study proved to be reliable, with encouraging success rates for an observation period of 36 months following placement.

  10. Retrospective Study on External Canine Limb Prosthesis used in 24 patients

    Directory of Open Access Journals (Sweden)

    Brittany Jean Carr

    2018-03-01

    Full Text Available Objective: The purpose of this retrospective study is to provide data regarding external prosthetic use in small animal patients, evaluate the common complications associated with external prosthetics, and evaluate the outcome of patients using an external prosthetic.Background: The use of external canine limb prosthetics is relatively uncommon in veterinary medicine today.  However, there is growing interest in prosthetics and their clinical application because these devices may offer an alternative to euthanasia in severe cases where full amputation or alternative methods of limb spare are not an option. The goal of the prosthesis is to provide a better quality of life, help prevent further deformation and degeneration of existing joints, decrease leg length discrepancies, increase exercise and activity levels, provide a means to participate in rehabilitation therapy and maintain the ability to perform daily acts of living. To the author’s knowledge, there is no report of external prosthetic use in small animal veterinary medicine, providing the profession with baseline information for use in, not only general practice or referral practice, but also future research.Evidentiary value: This retrospective study provides data regarding external prosthetic use in small animal patients, evaluates the procedures, manufacturing, rehabilitation and common complications associated with external prosthetics, and evaluates the factors that determine a patient’s prosthetic candidacy.Methods: Patients that had an external prosthesis custom manufactured for them at Animal Orthocare, LLC and had a complete medical record were identified for this study.  A client survey was completed via e-mail or telephone to collect further data about the patients, including age, weight, breed, sex, affected limb(s, reason for prosthesis, level of amputation, activities patient could perform with prosthesis in place, prosthetic fit, prosthetic migration (e

  11. Research, design and development project Myoelectric Prosthesis of Upper Limb

    International Nuclear Information System (INIS)

    Galiano, L; Montaner, E; Flecha, A

    2007-01-01

    A Research Design and Development Project was developed of a myoelectric prosthesis for a pediatric patient presenting congenital amputation of the left forearm below the elbow. A multidisciplinary work-team was formed for this goal, in order to solve the several (/various) aspects regarding this project (mechanical, ergonomics, electronics, physical). The prosthesis as an electromechanical device was divided in several blocks, trying to achieve a focused development for each stage, acording to requisites. A mechanical prototype of the prothesis was designed and built along with the circuitry needed for EMG aquisition, control logic and drivers. Having acomplished the previuos stages, the project is now dealing with the definitions of the interface between the prosthesis and the patient, with promising perspectives

  12. Research, design and development project Myoelectric Prosthesis of Upper Limb

    Energy Technology Data Exchange (ETDEWEB)

    Galiano, L; Montaner, E; Flecha, A [Bioparx, J Hernandez 1101, Parana, ERios (Argentina)

    2007-11-15

    A Research Design and Development Project was developed of a myoelectric prosthesis for a pediatric patient presenting congenital amputation of the left forearm below the elbow. A multidisciplinary work-team was formed for this goal, in order to solve the several (/various) aspects regarding this project (mechanical, ergonomics, electronics, physical). The prosthesis as an electromechanical device was divided in several blocks, trying to achieve a focused development for each stage, acording to requisites. A mechanical prototype of the prothesis was designed and built along with the circuitry needed for EMG aquisition, control logic and drivers. Having acomplished the previuos stages, the project is now dealing with the definitions of the interface between the prosthesis and the patient, with promising perspectives.

  13. 21 CFR 888.3170 - Elbow joint radial (hemi-elbow) polymer prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Elbow joint radial (hemi-elbow) polymer prosthesis. 888.3170 Section 888.3170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-elbow) polymer prosthesis. (a) Identification. An elbow joint radial (hemi-elbow) polymer...

  14. Prosthesis-patient mismatch due to small ring annuloplasty in patients with degenerative mitral insufficiency.

    Science.gov (United States)

    Kawamoto, Naonori; Fujita, Tomoyuki; Hata, Hiroki; Shimahara, Yusuke; Sato, Shunsuke; Kobayashi, Junjiro

    2016-08-01

    Avoidance of prosthesis-patient mismatch (PPM) is important when selecting a mitral valve prosthesis. This study investigated the effect of PPM after small ring mitral valve annuloplasty on postoperative hemodynamics and the clinical course. This study retrospectively reviewed 227 patients with symptomatic severe mitral insufficiency (MI) who underwent mitral valve repair for degenerative MI using an Edwards ring or band (size: 26-32mm) between 2003 and 2012. Echocardiography was performed postoperatively and at follow-up to evaluate cardiac function, including residual MI, mean transmitral pressure gradient, left atrial diameter (LAD), and tricuspid regurgitant pressure gradient (TRPG). There were no operative deaths. Actuarial freedom from major adverse cardiac events was 91% at 10 years. The postoperative MI grade was not significantly different between different sizes of prosthesis (26mm, 0.67±0.8; 28mm, 0.73±0.9; 30mm, 0.85±0.9; 32mm, 0.3±0.6). LAD and TRPG were significantly lower for each size of prosthesis at follow-up (all pbody surface area received a significantly smaller prosthesis (pprosthesis than in patients with a larger size of prosthesis. Thirty-three patients had a follow-up transmitral pressure gradient ≥5mmHg. The follow-up LAD was larger in patients with a transmitral pressure gradient prosthesis. However, use of a smaller prosthesis may result in a higher mean transmitral pressure gradient, and may inhibit reverse remodeling of the left atrium. Therefore, PPM should be avoided. Copyright © 2015 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  15. Evaluation of possible hip prosthesis infection with In-111 leukocyte scintigraphy

    International Nuclear Information System (INIS)

    Noto, R.B.; Alavi, A.; Star, A.M.; Cuckler, J.M.; Eisenberg, B.

    1987-01-01

    To evaluate the utility of In-111 leukocyte scintigraphy in patients with possible hip prosthesis infection, the authors retrospectively reviewed 44 such scans without clinical history. The results of In-111 leukocyte scans were compared with intraoperative cultures obtained at the time of prosthesis revision in 34 patients, with hip aspirates and/or clinical follow-up obtained in the remaining ten patients. This comparison yielded a 71% sensitivity, 78% specificity, and 77% overall accuracy. They conclude that In-111 leukocyte scans can be helpful in the evaluation of suspected hip prosthesis infection, but they are not as accurate as has been previously reported elsewhere

  16. A Structural Analysis of a Mechanical Heart Valve Prosthesis with Flat Leaflet

    Science.gov (United States)

    Kwon, Young Joo

    This paper addresses the basic concept of MDO methodology and the structural analysis that should be performed in the design process of a mechanical heart valve prosthesis with flat leaflet using MDO methodology. In the structural design of the mechanical heart valve (MHV) prosthesis, the fluid mechanics analysis is executed for the blood flow passing through the leaflets of a mechanical heart valve prosthesis. Thereafter, the rigid body dynamics analysis of the leaflet motion is performed to obtain the structural condition for the structural mechanics analysis of the deformed leaflet. Then the structural mechanics analysis of the deformed leaflet follows to confirm the minimum thickness of the leaflet for the structural durability of the mechanical heart valve prosthesis. This paper shows that the minimum leaflet thickness can be evaluated to be 0.6mm among the suggested thicknesses.

  17. Effect of silicone gel breast prosthesis on electron and photon dose distributions

    International Nuclear Information System (INIS)

    Krishnan, L.; St George, F.J.; Mansfield, C.M.; Krishnan, E.C.

    1983-01-01

    The effect of a silicone gel breast prosthesis on the absorbed dose distribution of 9--20 MeV electron beams and 1.25--15 MV photon beams was studied. Compared to water measurements, at depths smaller than the practical range of the electron beams, the central axis depth dose values below the prothesis were lower for all energies by as much as 3.5%. However, at depths near the practical range, the central axis depth dose values for the prosthesis were greater than that of water by as much as 33%. Since this occurs near the end of the electron range, the resultant difference may not be clinically significant. Results of the effect of breast prosthesis on photon depth dose distributions reveal that no clinically significant perturbation is produced by the breast prosthesis using Co-60, 6- and 15-MV radiations

  18. Quantifying risk of penile prosthesis infection with elevated glycosylated hemoglobin.

    Science.gov (United States)

    Wilson, S K; Carson, C C; Cleves, M A; Delk, J R

    1998-05-01

    Elevation of glycosylated hemoglobin above levels of 11.5 mg.% has been considered a contraindication to penile prosthesis implantation in diabetic patients. We determine the predictive value of glycosylated hemoglobin A1C in penile prosthesis infections in diabetic and nondiabetic patients to confirm or deny this prevalent opinion. We conducted a 2-year prospective study of 389 patients, including 114 diabetics, who underwent 3-piece penile prosthesis implantation. All patients had similar preoperative preparation without regard to diabetic status, control or glycosylated hemoglobin A1C level. Risk of infection was statistically analyzed for diabetics versus nondiabetics, glycosylated hemoglobin A1C values above and below 11.5 mg.%, insulin dependent versus oral medication diabetics, and fasting blood sugars above and below 180 mg.%. Prosthesis infections developed in 10 diabetics (8.7%) and 11 nondiabetics (4.0%). No increased infection rate was observed in diabetics with high fasting sugars or diabetics on insulin. There was no statistically significant increased infection risk with increased levels of glycosylated hemoglobin A1C among all patients or among only the diabetics. In fact, there was no meaningful difference in the median or mean level of glycosylated hemoglobin A1C in the infected and noninfected patients regardless of diabetes. Use of glycosylated hemoglobin A1C values to identify and exclude surgical candidates with increased risk of infections is not proved by this study. Elevation of fasting sugar or insulin dependence also does not increase risk of infection in diabetics undergoing prosthesis implantation.

  19. A comparative study of the incidence of aseptic meningitis in symptomatic natural mumps patients and monovalent mumps vaccine recipients in Japan.

    Science.gov (United States)

    Nagai, Takao; Okafuji, Teruo; Miyazaki, Chiaki; Ito, Yuhei; Kamada, Makoto; Kumagai, Takuji; Yuri, Kenji; Sakiyama, Hiroshi; Miyata, Akiko; Ihara, Toshiaki; Ochiai, Hitoshi; Shimomura, Kunihisa; Suzuki, Eitaro; Torigoe, Sadayoshi; Igarashi, Masahiro; Kase, Tetsuo; Okuno, Yoshinobu; Nakayama, Tetsuo

    2007-03-30

    To compare the incidence of aseptic meningitis associated with symptomatic natural mumps infection and in mumps vaccine recipients, we conducted a prospective comparative study. Consecutive samples of 1051 children with mumps were enrolled by 10 pediatricians and 21,465 vaccine recipients by 143 pediatric primary care practitioners, from January 1, 2000 to January 1, 2003. Parents used a daily diary to record symptoms during the period of illness (15 days) or 30-day period following immunization. Mumps infection was confirmed by virus isolation and/or detection of mumps virus genome in salivary and CSF samples. The incidence of aseptic meningitis was 13/1051 (1.24%) in patients with symptomatic natural mumps infection and was estimated to be 0.7-1.1% of overall infection in considering asymptomatic infection, and 10/21,465 (0.05%) in vaccine recipients. Although aseptic meningitis is a clear side effect of the mumps vaccine, the incidence is considerably lower than among those with symptomatic natural infection. Our results provide an informative data for consideration to resume mumps vaccine as a part of routine immunization schedule for Japanese children.

  20. Controlled Human Malaria Infection of Tanzanians by Intradermal Injection of Aseptic, Purified, Cryopreserved Plasmodium falciparum Sporozoites

    NARCIS (Netherlands)

    Shekalaghe, S.; Rutaihwa, M.; Billingsley, P.F.; Chemba, M.; Daubenberger, C.A.; James, E.R.; Mpina, M.; Juma, O. Ali; Schindler, T.; Huber, E.; Gunasekera, A.; Manoj, A.; Simon, B.; Saverino, E.; Church, L.W.; Hermsen, C.C.; Sauerwein, R.W.; Plowe, C.; Venkatesan, M.; Sasi, P.; Lweno, O.; Mutani, P.; Hamad, A.; Mohammed, A.; Urassa, A.; Mzee, T.; Padilla, D.; Ruben, A.; Sim, B.K.; Tanner, M.; Abdulla, S.; Hoffman, S.L.

    2014-01-01

    Controlled human malaria infection (CHMI) by mosquito bite has been used to assess anti-malaria interventions in > 1,500 volunteers since development of methods for infecting mosquitoes by feeding on Plasmodium falciparum (Pf) gametocyte cultures. Such CHMIs have never been used in Africa. Aseptic,

  1. Wispy Prosthesis: A Novel Method in Denture Weight Reduction.

    Science.gov (United States)

    Anne, Gopinadh; Budeti, Sreedevi; Anche, Sampath Kumar; Zakkula, Srujana; Atla, Jyothi; Jyothula, Ravi Rakesh Dev; Appana, Krishna Chaitanya; Peddinti, Vijaya Kumar

    2016-04-01

    Stability and retention of the denture becomes at stake with the increase in weight of the denture prosthesis. As a consequence, different materials and methods have been introduced to overcome these issues but denture weight reduction still remains to be a cumbersome and strenuous procedure. To introduce a novel technique for the fabrication of denture prosthesis where in the weight of the denture will not affect the retention and stability of the denture. Four groups with a sample size of 10 each, were included where in one group was control and other three were study groups. The control group samples were made completely solid and the study group samples were packed with materials like bean balls, cellulose balls and polyacrylic fibers. The weight of all the samples of each study group was measured and compared with the control group. The observations were analyzed statistically by paired t-test. It was observed that the bean balls group produced a weight reduction of 31.3%, cellulose balls group 27.4% and polyacrylic fibers group 24.5% when compared to that of the control group. This novel technique will eliminate the problems that were associated in creating hollowness and at the same time will reduce the weight of the prosthesis and among all the study groups, bean balls group were found to reduce maximum weight of the prosthesis.

  2. The principle of low frictional torque in the Charnley total hip replacement.

    Science.gov (United States)

    Wroblewski, B M; Siney, P D; Fleming, P A

    2009-07-01

    The design of the Charnley total hip replacement follows the principle of low frictional torque. It is based on the largest possible difference between the radius of the femoral head and that of the outer aspect of the acetabular component. The aim is to protect the bone-cement interface by movement taking place at the smaller radius, the articulation. This is achieved in clinical practice by a 22.225 mm diameter head articulating with a 40 mm or 43 mm diameter acetabular component of ultra-high molecular weight polyethylene. We compared the incidence of aseptic loosening of acetabular components with an outer diameter of 40 mm and 43 mm at comparable depths of penetration with a mean follow-up of 17 years (1 to 40). In cases with no measurable wear none of the acetabular components were loose. With increasing acetabular penetration there was an increased incidence of aseptic loosening which reflected the difference in the external radii, with 1.5% at 1 mm, 8.8% at 2 mm, 9.7% at 3 mm and 9.6% at 4 mm of penetration in favour of the larger 43 mm acetabular component. Our findings support the Charnley principle of low frictional torque. The level of the benefit is in keeping with the predicted values.

  3. Long-term result of cementless femoral stem in avascular necrosis of the hip.

    Science.gov (United States)

    Cheung, Kin W; Chiu, Kwok H; Chung, Kwong Y

    2015-01-01

    Avascular necrosis (AVN) of the hip may have extensive involvement of the proximal femur which may affect boney ingrowth into cementless femoral stems. From 1994 to 2004, 182 total hip arthroplasties (in 144 patients, 117 AVN hips and 65 non-AVN hips) were performed using hydroxyapatite coated femoral stems. All patients were followed up prospectively. Mean age was 51 years and mean follow-up 14.7 years (range 9.7-19.1 years). Four stems were revised because of aseptic loosening, 3 in AVN group and 1 in non-AVN group. The overall mechanical failure rate was 2.2%, the mechanical failure rate in AVN and non-AVN group was 2.6% and 1.5% respectively (p = 1). The 19.1 year survival using revision for aseptic loosening as an endpoint for AVN and non-AVN patients were 97.1% and 96.2% respectively (p = 0.654). Stable boney ingrowth was present in 99.5% hips. This study represents 1 of the largest series reporting the long-term follow-up of the use of cementless femoral stems in treating AVN of the hip. We report excellent long-term survival of cementless total hip arthroplasty used in managing AVN of the hip and is comparable to that seen in non-AVN total hip arthroplasty.

  4. A fiber-reinforced composite prosthesis restoring a lateral midfacial defect: a clinical report.

    Science.gov (United States)

    Kurunmäki, Hemmo; Kantola, Rosita; Hatamleh, Muhanad M; Watts, David C; Vallittu, Pekka K

    2008-11-01

    This clinical report describes the use of a glass fiber-reinforced composite (FRC) substructure to reinforce the silicone elastomer of a large facial prosthesis. The FRC substructure was shaped into a framework and embedded into the silicone elastomer to form a reinforced facial prosthesis. The prosthesis is designed to overcome the disadvantages associated with traditionally fabricated prostheses; namely, delamination of the silicone of the acrylic base, poor marginal adaptation over time, and poor simulation of facial expressions.

  5. Subway Mandibular Buccal Defect Blocked with Two Part Prosthesis Unified by Earth Magnets

    OpenAIRE

    Punjani, Shikha; Arora, Aman; Upadhyaya, Viram

    2012-01-01

    This clinical report describes the fabrication of a two-piece obturator used to close the mandibular buccal defect. Two-piece obturator prosthesis was fabricated with clear heat cure acrylic resin to be used during the healing period following the marsupialization of odontogenic keratocyst which had lead to the loss of portions of the mandibular buccal region. The prosthesis fabricated in two parts was joined by the rare earth magnets. Retention was increased by lining the prosthesis with tis...

  6. Aspiration of tracheoesophageal prosthesis in a laryngectomized patient

    Directory of Open Access Journals (Sweden)

    Conte Sergio C

    2012-08-01

    Full Text Available Abstract Background The voice prosthesis inserted into a tracheoesophageal fistula has become the most widely used device for voice rehabilitation in patients with total laryngectomy. Case presentation We describe a case of tracheoesophageal prosthesis’ (TEP aspiration in a laryngectomized patient, with permanent tracheal stoma, that appeared during standard cleaning procedure, despite a programme of training for the safe management of patients with voice prosthesis. Conclusions The definitive diagnosis and treatment were performed by flexible bronchoscopy, that may be considered the procedure of choice in these cases, also on the basis of the literature.

  7. Tracheobronchial Foreign Body Aspiration: Dental Prosthesis

    Directory of Open Access Journals (Sweden)

    Ataman Köse

    2014-01-01

    Full Text Available It is important to extract foreign bodies for avoiding life-threatening complications. They can lead to death if they are not treated. Different signs and symptoms could occur according to the complete or partial airway obstruction. Foreign body aspiration is a rare incident in adults. The organic foreign materials such as foods are found to be aspirated more commonly and are usually settled in the right bronchial system. However, dental prosthesis and teeth aspirations are rare in literature. In our study, a 52-year-old male patient who had aspirated the front part of his lower dental prosthesis accidentally is presented and the foreign body is extracted by using rigid bronchoscopy. There are many causes of aspiration but dental prosthetic aspirations should be kept in mind during sleep. For this reason, dental apparatus must be taken out while asleep.

  8. Stress analysis of different prosthesis materials in implant-supported fixed dental prosthesis using 3D finite element method

    Directory of Open Access Journals (Sweden)

    Pedram Iranmanesh

    2014-01-01

    Full Text Available Introduction: In the present study, the finite element method (FEM was used to investigate the effects of prosthesis material types on stress distribution of the bone surrounding implants and to evaluate stress distribution in three-unit implant-supported fixed dental prosthesis (FDP. Materials and Methods: A three-dimensional (3D finite element FDP model of the maxillary second premolar to the second molar was designed. Three load conditions were statically applied on the functional cusps in horizontal (57.0 N, vertical (200.0 N, and oblique (400.0 N, θ = 120° directions. Four standard framework materials were evaluated: Polymethyl methacrylate (PMMA, base-metal, porcelain fused to metal, andporcelain. Results: The maximum of von Mises stress in the oblique direction was higher than the vertical and horizontal directions in all conditions. In the bone-crestal section, the maximum von Mises stress (53.78 MPa was observed in PMMA within oblique load. In FDPs, the maximum stress was generated at the connector region in all conditions. Conclusion: A noticeable difference was not observed in the bone stress distribution pattern with different prosthetic materials. Although, higher stress value could be seen in polymethyl methacrylate, all types of prosthesis yielded the same stress distribution pattern in FDP. More clinical studies are needed to evaluate the survival rate of these materials.

  9. [Clinical effect modified Chevron osteotomy combined with lateral tissue loosening in treating mild-moderate hallux valgus through internal signal approach].

    Science.gov (United States)

    Chen, Xue-Qiang; Wu, Qun-Feng; Dong, Wei-Qin; Yu, Li-Xin; Li, Xiong-Feng

    2018-03-25

    To explore clinical effect of modified Chevron osteotomy combined with lateral tissue loosening for the treatment of mild-moderate hallux valgus through internal signal approach. From July 2015 to June 2016, 26 patients with mild-moderate hallux valgus treated with modified Chevron osteotomy combined with lateral tissue loosening through internal signal approach, including 2 males and 24 females aged from 45 to 65 years old with an average of(54.6±4.8) years old;the courses of diseases ranged from 1 to 5 months with an average of (7.5±3.3) months. Hallux valgus angle(HVA), inter metatarsal angle(IMA) were measured at 12 months after operation, and AOFAS score was applied to evaluate clinical effect before and after operation. All incisions were healed at stage I. No incision occurred infection, metatarsal necrosis and recurrence of hallux valgus deformity. Two patients occurred skin numbness caused by musculocutaneous nerve injury. Twenty-six patients were followed up from 6 to 12 months with an average of(9.12±2.06) months. HVA, IMA were(30.01±3.71)°, (14.00±1.50)° before operation and(9.41±4.16)°, (7.00±0.60)° after operation, which had significant difference. There was statistical significance in AOFAS score before operation 54.77±9.59 and after operation 92.73±5.47, and 19 cases obtained excellent results and 7 moderate. Modified Chevron osteotomy combined with full thread headless pressure screw fixation and lateral tissue loosening for the treatment of mild-moderate hallux valgus has advantages of excellent exposure, simple operation, stable fixation, rapid recovery. Akin osteotomy with internal capsulorrhaphy were used with lateral loosening and could recover soft tissue balance between lateral and internal, and could receive satisfied clinical effects. Copyright© 2018 by the China Journal of Orthopaedics and Traumatology Press.

  10. Adjuvant Maneuvers for Residual Curvature Correction During Penile Prosthesis Implantation in Men with Peyronie's Disease.

    Science.gov (United States)

    Berookhim, Boback M; Karpman, Edward; Carrion, Rafael

    2015-11-01

    The surgical treatment of comorbid erectile dysfunction and Peyronie's disease has long included the implantation of an inflatable penile prosthesis as well as a number of adjuvant maneuvers to address residual curvature after prosthesis placement. To review the various surgical options for addressing curvature after prosthesis placement, with specific attention paid to an original article by Wilson et al. reporting on modeling over a penile prosthesis for the management of Peyronie's disease. A literature review was performed analyzing articles reporting the management of penile curvature in patients undergoing implantation of an inflatable penile prosthesis. Reported improvement in Peyronie's deformity as well as the complication rate associated with the various surgical techniques described. Modeling is a well-established treatment modality among patients with Peyronie's disease undergoing penile prosthesis implantation. A variety of other adjuvant maneuvers to address residual curvature when modeling alone is insufficient has been presented in the literature. Over 20 years of experience with modeling over a penile prosthesis have proven the efficacy and safety of this treatment option, providing the surgeon a simple initial step for the management of residual curvature after penile implantation which allows for the use of additional adjuvant maneuvers in those with significant deformities. © 2015 International Society for Sexual Medicine.

  11. Insidious strut fractures in a DeBakey-Surgitool aortic valve prosthesis.

    Science.gov (United States)

    Scott, S M; Sethi, G K; Paulson, D M; Takaro, T

    1978-04-01

    Recent reports of cage wear occurring in DeBakey-Surgitool aortic valve prostheses prompted us to examine with image intensification all our patients who have had this type of prosthesis implanted. One patient, who was asymptomatic, was discovered to have a prosthesis with two fractured struts. This patient's prosthetic valve was replaced successfully with a stented porcine heterograft prosthesis. Including the valve removed from this patient, 8 DeBakey-Surgitool aortic valves with structural defects have been reported to the manufacturer. In the absence of a catastrophic event, patients with valves having fractured or worn struts may be totally asymptomatic, and routine periodic roentgenographic examination may be the only way of detecting strut wear or fracture.

  12. Determining the degree of break up of coal strata and clay interlayers by looseners at the Chukurovo pit

    Energy Technology Data Exchange (ETDEWEB)

    Atanasov, A B; Stoyanov, D S; Yordanov, Y M

    1983-01-01

    One of the rational technologies for selective mining of thin coal strata with complex geological structure is that one in which different types of mechanical looseners are used. Identification of the degree of break up of the rock is accomplished most rapidly and precisely using seismoacoustical methods. The evaluation is conducted relative to the speed of propagation of elastic waves in the mass. SVM seismic receivers were used at the Chukurovo pit to determine the speed of propagation of an elastic wave in coals and clays. Shafts 10 meters long were drilled in three experimental fields using the SVB-2 machine. The speed of propagation of an elastic wave in the coals and in sandy clays was determined for different shaft depths every meter. After comparing the obtained results with standard tables from different companies, the possibility of breaking up the coal and clay interlayers in the experimental sectors by looseners with motors different in type and capacity was determined.

  13. A Biomechanical Model for the Development of Myoelectric Hand Prosthesis Control Systems

    NARCIS (Netherlands)

    Peerdeman, B.; van Baal, D.W.; Boere, Daphne; Kallenberg, L.A.C.; Stramigioli, Stefano; Misra, Sarthak

    2010-01-01

    Advanced myoelectric hand prostheses aim to reproduce as much of the human hand's functionality as possible. Development of the control system of such a prosthesis is strongly connected to its mechanical design; the control system requires accurate information on the prosthesis' structure and the

  14. Excacerbation of systemic lupus erythematodes, aseptic meningitis and acute mental symptoms, following metrizamide lumbar myelography

    Energy Technology Data Exchange (ETDEWEB)

    Gelmers, H J

    1984-01-01

    A clinical constellation of excacerbation of systemic lupus erythematodes (SLE), together with aseptic meningitis, and acutre mental symptoms occurred following lumbar myelography with metrizamide. Excacerbation of SLE has not been previously described following myelography with any contrast agent. Meningeal reactions and acute mental symptoms have been reported earlier, but this clinical constellation is new.

  15. Excacerbation of systemic lupus erythematodes, aseptic meningitis and acute mental symptoms, following metrizamide lumbar myelography

    International Nuclear Information System (INIS)

    Gelmers, H.J.

    1984-01-01

    A clinical constellation of excacerbation of systemic lupus erythematodes (SLE), together with aseptic meningitis, and acutre mental symptoms occurred following lumbar myelography with metrizamide. Excacerbation of SLE has not been previously described following myelography with any contrast agent. Meningeal reactions and acute mental symptoms have been reported earlier, but this clinical constellation is new. (orig.)

  16. Imaging of knee arthroplasty

    International Nuclear Information System (INIS)

    Miller, Theodore T.

    2005-01-01

    Knee replacement surgery, either with unicompartmental or total systems, is common. The purpose of this manuscript is to review the appearance of normal knee arthroplasty and the appearances of complications such as infection, polyethylene wear, aseptic loosening and particle-induced osteolysis, patellofemoral abnormalities, axial instability, and periprosthetic and component fracture. Knowledge of the potential complications and their imaging appearances will help the radiologist in the diagnostic evaluation of the patient with a painful knee arthroplasty

  17. Imaging of knee arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Theodore T. [Department of Radiology, North Shore University Hospital, 825 Northern Blvd., Great Neck, NY 11021 (United States)]. E-mail: TMiller@NSHS.edu

    2005-05-01

    Knee replacement surgery, either with unicompartmental or total systems, is common. The purpose of this manuscript is to review the appearance of normal knee arthroplasty and the appearances of complications such as infection, polyethylene wear, aseptic loosening and particle-induced osteolysis, patellofemoral abnormalities, axial instability, and periprosthetic and component fracture. Knowledge of the potential complications and their imaging appearances will help the radiologist in the diagnostic evaluation of the patient with a painful knee arthroplasty.

  18. Good performance of a titanium femoral component in cementless hip arthroplasty in younger patients: 97 arthroplasties followed for 5-11 years

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Jensen, Frank Krieger; Poulsen, Klaus

    2003-01-01

    We performed 97 uncemented primary total hip arthroplasties in 80 patients having an average age of 50 years. The femoral implant was a titanium stem with a proximal circumferential plasma spray-coating. Three different acetabular components were used: a threaded and partly porous-coated design i...... titanium femoral component with a circumferential porous coating performed well in these patients, most of whom were young. As reported previously, aseptic loosening of threaded acetabular components was common....

  19. Utilization of penile prosthesis and male incontinence prosthetics in Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Amjad Alwaal

    2017-01-01

    Conclusions: There is an increased utilization of penile prosthetics in Saudi Arabia. The private sector performs the majority of penile prosthesis procedures, and most of them are of the semirigid type. The governmental sector is more likely to perform inflatable penile prosthesis and male incontinence device procedures. Male incontinence prosthetics' use is very limited in Saudi Arabia.

  20. An “Uncrimped” SMart Stapes Prosthesis: A Cause of Late Hearing Deterioration in Otosclerosis

    Directory of Open Access Journals (Sweden)

    Premjit S. Randhawa

    2012-01-01

    Full Text Available Statement of Problem. Stapedotomy is the treatment of choice for otosclerosis. Numerous techniques and prosthesis are available to perform this procedure. Success rates of surgery vary from 17% to 80%, and revision surgery carries an increased risk of complications as well as poorer hearing outcomes. Method of Study. Case report. Results. We report the first case of uncrimping of a SMart stapes prosthesis with no lateral displacement as a cause of late failure despite successful crimping and improvement in audiological outcomes after initial surgery. Conclusion. The SMart stapes prosthesis is widely used and has been shown to be safe and provide good hearing outcomes. Displacement of a stapes prosthesis is the commonest cause of failure. Our case shows that deterioration of hearing thresholds can occur from uncrimping of the prosthesis with no displacement. It is important to improve our understanding of stapedotomy failure as revision procedures are associated with poorer outcomes.

  1. Added value of experts' knowledge to improve a quantitative microbial exposure assessment model--Application to aseptic-UHT food products.

    Science.gov (United States)

    Pujol, Laure; Johnson, Nicholas Brian; Magras, Catherine; Albert, Isabelle; Membré, Jeanne-Marie

    2015-10-15

    In a previous study, a quantitative microbial exposure assessment (QMEA) model applied to an aseptic-UHT food process was developed [Pujol, L., Albert, I., Magras, C., Johnson, N. B., Membré, J. M. Probabilistic exposure assessment model to estimate aseptic UHT product failure rate. 2015 International Journal of Food Microbiology. 192, 124-141]. It quantified Sterility Failure Rate (SFR) associated with Bacillus cereus and Geobacillus stearothermophilus per process module (nine modules in total from raw material reception to end-product storage). Previously, the probabilistic model inputs were set by experts (using knowledge and in-house data). However, only the variability dimension was taken into account. The model was then improved using expert elicitation knowledge in two ways. First, the model was refined by adding the uncertainty dimension to the probabilistic inputs, enabling to set a second order Monte Carlo analysis. The eight following inputs, and their impact on SFR, are presented in detail in this present study: D-value for each bacteria of interest (B. cereus and G. stearothermophilus) associated with the inactivation model for the UHT treatment step, i.e., two inputs; log reduction (decimal reduction) number associated with the inactivation model for the packaging sterilization step for each bacterium and each part of the packaging (product container and sealing component), i.e., four inputs; and bacterial spore air load of the aseptic tank and the filler cabinet rooms, i.e., two inputs. Second, the model was improved by leveraging expert knowledge to develop further the existing model. The proportion of bacteria in the product which settled on surface of pipes (between the UHT treatment and the aseptic tank on one hand, and between the aseptic tank and the filler cabinet on the other hand) leading to a possible biofilm formation for each bacterium, was better characterized. It was modeled as a function of the hygienic design level of the aseptic

  2. Prosthesis Prescription Protocol of the Arm (PPP-Arm) : The implementation of a national prosthesis prescription protocol

    NARCIS (Netherlands)

    Wijdenes, Paula; Brouwers, Michael; van der Sluis, Corry K

    BACKGROUND AND AIM: In order to create more uniformity in the prescription of upper limb prostheses by Dutch rehabilitation teams, the development and implementation of a Prosthesis Prescription Protocol of the upper limb (PPP-Arm) was initiated. The aim was to create a national digital protocol to

  3. PARTIAL REPLACEMENT OF THE ESOPHAGEAL MUSCLE LAYERS BY A CARBON-FIBER PROSTHESIS

    NARCIS (Netherlands)

    RUKA, MP; TUNGEKAR, MF; KUIT, J; HOFSTRA, W

    1991-01-01

    In the present study we report on the surgical replacement of the thoracic portion of oesophageal muscularis by a synthetic carbon fibre (CF) prosthesis in a rabbit model. Our results, as corroborated by the oesophagograms and the post-operative weight gain, showed that this prosthesis functioned

  4. Restoration of an atrophic eye socket with custom made eye prosthesis, utilizing digital photography

    Directory of Open Access Journals (Sweden)

    Gaurav P Jayaswal

    2011-01-01

    Full Text Available Ocular defects may cause several ocular and orbital disorders, which require surgical intervention. These defects are psychologically disturbing for the patients, and therefore, they require immediate management and rehabilitation by a team of specialist. Ocular prosthesis may be either readymade (stock or custom made. Fabrication of a custom ocular prosthesis allows for a range of variations during construction. The iris can also be custom made by ocular painting or by digital photography. The optimum cosmetic and functional results of a custom-made prosthesis enhance the patient′s rehabilitation to a normal life style. This paper elaborates the technique for fabrication of a custom-made ocular prosthesis for an atrophic eye socket utilizing digital photography.

  5. Optimization of Visual Information Presentation for Visual Prosthesis

    Directory of Open Access Journals (Sweden)

    Fei Guo

    2018-01-01

    Full Text Available Visual prosthesis applying electrical stimulation to restore visual function for the blind has promising prospects. However, due to the low resolution, limited visual field, and the low dynamic range of the visual perception, huge loss of information occurred when presenting daily scenes. The ability of object recognition in real-life scenarios is severely restricted for prosthetic users. To overcome the limitations, optimizing the visual information in the simulated prosthetic vision has been the focus of research. This paper proposes two image processing strategies based on a salient object detection technique. The two processing strategies enable the prosthetic implants to focus on the object of interest and suppress the background clutter. Psychophysical experiments show that techniques such as foreground zooming with background clutter removal and foreground edge detection with background reduction have positive impacts on the task of object recognition in simulated prosthetic vision. By using edge detection and zooming technique, the two processing strategies significantly improve the recognition accuracy of objects. We can conclude that the visual prosthesis using our proposed strategy can assist the blind to improve their ability to recognize objects. The results will provide effective solutions for the further development of visual prosthesis.

  6. Optimization of Visual Information Presentation for Visual Prosthesis

    Science.gov (United States)

    Gao, Yong

    2018-01-01

    Visual prosthesis applying electrical stimulation to restore visual function for the blind has promising prospects. However, due to the low resolution, limited visual field, and the low dynamic range of the visual perception, huge loss of information occurred when presenting daily scenes. The ability of object recognition in real-life scenarios is severely restricted for prosthetic users. To overcome the limitations, optimizing the visual information in the simulated prosthetic vision has been the focus of research. This paper proposes two image processing strategies based on a salient object detection technique. The two processing strategies enable the prosthetic implants to focus on the object of interest and suppress the background clutter. Psychophysical experiments show that techniques such as foreground zooming with background clutter removal and foreground edge detection with background reduction have positive impacts on the task of object recognition in simulated prosthetic vision. By using edge detection and zooming technique, the two processing strategies significantly improve the recognition accuracy of objects. We can conclude that the visual prosthesis using our proposed strategy can assist the blind to improve their ability to recognize objects. The results will provide effective solutions for the further development of visual prosthesis. PMID:29731769

  7. 21 CFR 878.3750 - External prosthesis adhesive.

    Science.gov (United States)

    2010-04-01

    ... used to fasten to the body an external aesthetic restoration prosthesis, such as an artificial nose. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in...

  8. Development of a cosmetic knee disarticulation prosthesis : A single-patient case study

    NARCIS (Netherlands)

    de Laat, Fred A.; de Vos, Wouter; Geertzen, Jan; Roorda, Leo D.

    2015-01-01

    Background and aim: If a person does not become ambulant after an amputation, a knee disarticulation (KD) shouldbe considered and the person may then benefit from a cosmetic KD prosthesis. The features of a cosmetic KD prosthesis are, however, seldom described. The aim of this clinical note is to

  9. 21 CFR 888.3110 - Ankle joint metal/polymer semi-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ankle joint metal/polymer semi-constrained... Ankle joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an ankle...

  10. Conception, design and development of a low-cost intelligent prosthesis for one-sided transfemoral amputees

    Directory of Open Access Journals (Sweden)

    Wilson Carlos da Silva Júnior

    Full Text Available Introduction Modern transfemoral knee prostheses are designed to offer comfort and self-confidence to amputees. These prostheses are mainly based upon either a passive concept, with a damping system, or an active computational intelligent design to control knee motion during the swing phase. In Brazil, most lower extremity amputees are unable to afford modern prostheses due to their high cost. In this work, we present the conception, design and development of a low-cost intelligent prosthesis for one-sided transfemoral amputees. Methods The concept of the prosthesis is based on a control system with sensors for loads, which are installed on the amputee’s preserved leg and used as a mirror for the movement of the prosthesis. Mechanical strength analysis, using the Finite Element Method, electromechanical tests for the sensors and actuators and verification of data acquisition, signal conditioning and data transferring to the knee prosthesis were performed. Results The laboratory tests performed showed the feasibility of the proposed design. The electromechanical concept that was used enabled a controlled activation of the knee prosthesis by the two load cells located on the shoe sole of the preserved leg. Conclusions The electromechanical design concept and the resulting knee prosthesis show promising results concerning prosthesis activation during walking tests, thereby showing the feasibility of a reduced manufacturing cost compared to the modern prostheses available on the market.

  11. Artroplastia total coxofemoral em cães: Estudo experimental com prótese nacional Total hip arthroplasty in dogs: Experimental study using a prosthesis made in Brazil

    Directory of Open Access Journals (Sweden)

    Bruno Watanabe Minto

    2008-02-01

    Full Text Available A prótese total da articulação coxofemoral representa uma das técnicas mais aceitas, nos Estados Unidos e na Europa, para o tratamento cirúrgico da displasia coxofemoral severa em cães. Entretanto, ainda é pouco difundida e estudada no Brasil. No presente trabalho, foi utilizada prótese confeccionada no Brasil, com o objetivo de avaliar a sua aplicação, evolução pós-operatória e complicações associadas. Foram utilizados dez cães, sadios e adultos. Todos foram submetidos ao procedimento de prótese total cimentada da articulação esquerda utilizando-se um componente femoral de cromo-cobalto, cabeça fixa, e uma cúpula acetabular de polietileno de alta densidade. As avaliações clínicas e radiográficas foram realizadas no pré-operatório e aos 30, 60, 90, 120 e 150 dias após a intervenção cirúrgica. A prótese total utilizada proporcionou um bom resultado funcional ao membro operado, em 80% dos animais. As principais complicações relacionadas foram a luxação protética e a soltura do componente acetabular.Total hip prosthesis is one of the most accepted methods used in the United States and Europe for the treatment of severe hip dysplasia in dogs. However, there are few studies with the technique and the procedure is still not well established in Brazil. A prosthesis made in Brazil was used. The purpose of this study was to evaluate its application and determine the postoperative finds and complications. Ten mature healthy dogs were used. A fixed-head cemented total hip prosthesis was applied on the left leg of the dogs. A chrome-cobalt femoral stem and high density polyetylene acetabular cup was used. Clinical and radiographic evaluations were performed before surgery and again at 30, 60, 90, 120 e 150 days post operation. Proper weight bearing was noticed on the operated limb in the majority of the dogs. The main complications were the dislocation and loosening of the acetabular cup.

  12. Self and partner satisfaction rates after 3 part inflatable penile prosthesis implantation.

    Science.gov (United States)

    Simsek, Abdulmuttalip; Kucuktopcu, Onur; Ozgor, Faruk; Ozkuvanci, Unsal; Baykal, Murat; Sarilar, Omer; Gurbuz, Zafer Gokhan

    2014-09-30

    To evaluate and present satisfaction rates of our patients and their partners after 3 part inflatable penile prosthesis implantation. We searched our hospital electronic data for patients who underwent inflatable penile prosthesis implantation between January 2008 and July 2013. Computer and archived file data were used to get information and reach the patients. We made telephone calls to patients and asked questionnaires about self and partner satisfaction rates. 36 patients underwent prosthesis implantation during the 5 year period. We were able to reach by telephone call 18 of them. The mean age of 18 patients was 55.7 ± 9.4 years and mean body mass index was 24.6 ± 2.1 kg/m2. The etiology was diabetes mellitus on 14 (77.8%) and radical pelvic surgery on 4 (22.2%) patients. 14 of 18 patients had penile Doppler ultrasound test. Doppler ultrasound demonstrated venous insufficiency in 8 and arterial insufficiency in 6 patients. Mean time from implantation to study was 20.8 ± 13.9 months. Out of 18 patients 2 had prosthesis removal operation because of infection in one patient and perforation in the other. Satisfaction rate was 88.9%, and recommendation rate was 94.4%. Causes of dissatisfaction were pain in one patient and insufficient rigidity plus shortening of the penis in the other one. Partner satisfaction rate was 94.4%. Penile Prosthesis Implantation (PPI) is the gold standard treatment of erectile dysfunction (ED) irresponsive to medical treatment. Infection and mechanical failure rates are going to be less according to the improvements in synthetic materials and coverings of the prosthesis, so patient and partner satisfaction rates will be higher.

  13. A prosthesis-specific multi-link segment model of lower-limb amputee sprinting.

    Science.gov (United States)

    Rigney, Stacey M; Simmons, Anne; Kark, Lauren

    2016-10-03

    Lower-limb amputees commonly utilize non-articulating energy storage and return (ESAR) prostheses for high impact activities such as sprinting. Despite these prostheses lacking an articulating ankle joint, amputee gait analysis conventionally features a two-link segment model of the prosthetic foot. This paper investigated the effects of the selected link segment model׳s marker-set and geometry on a unilateral amputee sprinter׳s calculated lower-limb kinematics, kinetics and energetics. A total of five lower-limb models of the Ottobock ® 1E90 Sprinter were developed, including two conventional shank-foot models that each used a different version of the Plug-in-Gait (PiG) marker-set to test the effect of prosthesis ankle marker location. Two Hybrid prosthesis-specific models were then developed, also using the PiG marker-sets, with the anatomical shank and foot replaced by prosthesis-specific geometry separated into two segments. Finally, a Multi-link segment (MLS) model was developed, consisting of six segments for the prosthesis as defined by a custom marker-set. All full-body musculoskeletal models were tested using four trials of experimental marker trajectories within OpenSim 3.2 (Stanford, California, USA) to find the affected and unaffected hip, knee and ankle kinematics, kinetics and energetics. The geometry of the selected lower-limb prosthesis model was found to significantly affect all variables on the affected leg (p prosthesis-specific spatial, inertial and elastic properties from full-body models significantly affects the calculated amputee gait characteristics, and we therefore recommend the implementation of a MLS model. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Aseptic meningitis outbreak associated with echovirus 30 among high school football players--Los Angeles County, California, 2014.

    Science.gov (United States)

    Croker, Curtis; Civen, Rachel; Keough, Kathleen; Ngo, Van; Marutani, Amy; Schwartz, Benjamin

    2015-01-02

    On August 4, 2014, the Acute Communicable Disease Control Program of the Los Angeles County Department of Public Health received a report of three aseptic meningitis cases among football players at a county high school. An investigation was conducted to determine the extent of the outbreak, identify potential exposures, and recommend control measures. An outbreak-associated aseptic meningitis case was defined as an illness of any team or family member with onset during July 28-August 11 with 1) cerebrospinal fluid pleocytosis and negative bacterial culture or 2) an emergency department visit with headache, fever, and stiff neck. Ten cases were identified; nine in males, and one in a female; patient ages ranged from 13 to 17 years. All the patients sought care at an emergency department, and five were hospitalized, resulting in 12 total hospital days. All 10 patients have recovered. Eight patients were football players, and two were siblings of football players. The most affected subgroup was the junior varsity football team, with seven cases out of 57 players (attack rate = 12.3%); the relative risk for aseptic meningitis was higher among players who were linemen than among those who were not linemen (relative risk = 5.4 [p = 0.03]). Of the 10 patients, eight tested positive by polymerase chain reaction for enterovirus, and two were not tested. Echovirus testing was performed at the California Viral and Rickettsial Disease Laboratory. Of the eight specimens testing positive for enterovirus, seven tested positive for echovirus 30, and one specimen could not be typed because of insufficient quantity.

  15. Teaching aseptic technique for central venous access under ultrasound guidance: a randomized trial comparing didactic training alone to didactic plus simulation-based training.

    Science.gov (United States)

    Latif, Rana K; Bautista, Alexander F; Memon, Saima B; Smith, Elizabeth A; Wang, Chenxi; Wadhwa, Anupama; Carter, Mary B; Akca, Ozan

    2012-03-01

    Our goal was to determine whether simulation combined with didactic training improves sterile technique during ultrasound (US)-guided central venous catheter (CVC) insertion compared with didactic training alone among novices. We hypothesized that novices who receive combined didactic and simulation-based training would perform similarly to experienced residents in aseptic technique, knowledge, and perception of comfort during US-guided CVC insertion on a simulator. Seventy-two subjects were enrolled in a randomized, controlled trial of an educational intervention. Fifty-four novices were randomized into either the didactic group or the simulation combined with didactic group. Both groups received didactic training but the simulation combined with didactic group also received simulation-based CVC insertion training. Both groups were tested by demonstrating US-guided CVC insertion on a simulator. Aseptic technique was scored on 8 steps as "yes/no" and also using a 7-point Likert scale with 7 being "excellent technique" by a rater blinded to subject randomization. After initial testing, the didactic group was offered simulation-based training and retesting. Both groups also took a pre- and posttraining test of knowledge and rated their comfort with US and CVC insertion pre- and posttraining on a 5-point Likert scale. Subsequently, 18 experienced residents also took the test of knowledge, rated their comfort level, and were scored while performing aseptic US-guided CVC insertion using a simulator. The simulation combined with didactic group achieved a 167% (95% confidence interval [CI] 133%-167%) incremental increase in yes/no scores and 115% (CI 112%-127%) incremental increase in Likert scale ratings on aseptic technique compared with novices in the didactic group. Compared with experienced residents, simulation combined with didactic trained novices achieved an increase in aseptic scores with a 33.3% (CI 16.7%-50%) increase in yes/no ratings and a 20% (CI 13

  16. Maxillary palatal ramp prosthesis: A prosthodontic solution to manage mandibular deviation following surgery

    Directory of Open Access Journals (Sweden)

    Sampa Ray (Bhattacharya

    2015-01-01

    Full Text Available Mandibular resection following surgical treatment for neoplastic lesions of the oral cavity leads to numerous complications including altered mandibular movements, disfigurement, difficult in swallowing, impaired speech and articulation, and deviation of the mandible towards the resected site. Various prosthetic methods are employed to reduce or minimize mandibular deviation and improve and restore the lost functions and esthetic, like maxillomandibular fixation, implant supported prosthesis, removable mandibular guide flange prosthesis, and palatal based guidance restoration. This clinical report describes the rehabilitation of a patient following segmental mandibulectomy using palatal ramp prosthesis.

  17. A new and simple method of fabrication of tracheostomal prosthesis

    Directory of Open Access Journals (Sweden)

    N Vidya Sankari

    2015-01-01

    Full Text Available Patients with a tracheostomy stoma experience compromised speech and function due to the associated changes in airflow patterns. Rehabilitation of a patient with tracheal stoma is a highly challenging task. The main objective is to design an inexpensive, easily fabricated stomal prosthesis for postlaryngectomy patients who require prolonged tracheotomy. This clinical case report describes a 29-year-old male patient who underwent for tracheotomy 3 months before for respiratory distress following a suicidal attempt. Hence tracheotomy was done, and the patient has been with the tracheostomal tube since surgery for the past 3 months. Laryngoscopy examination reported as restricted bilateral vocal cord movements, and the cords were in the adducted position with minimal glottic chink. No history of difficulty in swallowing. On examination, no scar or ulceration is seen around the stoma. The skin around the stoma is healthy. The patient was referred to the oral and maxillofacial Prosthodontics Department from the Department of ENT. The patient′s old tracheostomal tube was used as the dimensions of the custom made tracheal prosthesis without making a functional impression of the mature stoma. A tracheal button was made with 2 mm polyethylene urethane sheet to maintain the airway patency of the mature stoma. Width and length of the old tracheostomal tube were measured and customized with polyurethane sheet by directly flaming over heat. The finished product was thin, flexible, maintains enhanced tear strength, require no tapes or adhesives and less technique sensitive. These properties of the prosthesis make more advantageous than the commercially available tracheal buttons. The result in this patient was excellent with no postoperative complications. An innovative approach for fabrication of tracheostomal prosthesis was discussed to increase its successful use in tracheostomal patients. The patient′s old tracheostomal tube was used as the dimensions

  18. Game-Based Rehabilitation for Myoelectric Prosthesis Control.

    Science.gov (United States)

    Prahm, Cosima; Vujaklija, Ivan; Kayali, Fares; Purgathofer, Peter; Aszmann, Oskar C

    2017-02-09

    A high number of upper extremity myoelectric prosthesis users abandon their devices due to difficulties in prosthesis control and lack of motivation to train in absence of a physiotherapist. Virtual training systems, in the form of video games, provide patients with an entertaining and intuitive method for improved muscle coordination and improved overall control. Complementary to established rehabilitation protocols, it is highly beneficial for this virtual training process to start even before receiving the final prosthesis, and to be continued at home for as long as needed. The aim of this study is to evaluate (1) the short-term effects of a commercially available electromyographic (EMG) system on controllability after a simple video game-based rehabilitation protocol, and (2) different input methods, control mechanisms, and games. Eleven able-bodied participants with no prior experience in EMG control took part in this study. Participants were asked to perform a surface EMG test evaluating their provisional maximum muscle contraction, fine accuracy and isolation of electrode activation, and endurance control over at least 300 seconds. These assessments were carried out (1) in a Pregaming session before interacting with three EMG-controlled computer games, (2) in a Postgaming session after playing the games, and (3) in a Follow-Up session two days after the gaming protocol to evaluate short-term retention rate. After each game, participants were given a user evaluation survey for the assessment of the games and their input mechanisms. Participants also received a questionnaire regarding their intrinsic motivation (Intrinsic Motivation Inventory) at the end of the last game. Results showed a significant improvement in fine accuracy electrode activation (Pgames when collecting items and facing challenging game play. Most upper limb amputees use a 2-channel myoelectric prosthesis control. This study demonstrates that this control can be effectively trained by

  19. An Underreported Consequence of Obesity in Pregnancy: Patient-Prosthesis Mismatch

    OpenAIRE

    Hartman, William R.; Arendt, Katherine W.; Rehfeldt, Kent H.

    2012-01-01

    As the rate of obesity increases in childbearing-aged women, so too will the complications of obesity in pregnancy. An uncommon and likely underreported complication occurs in obese women who have received prepregnancy cardiac valve replacement with a prosthesis that is inadequately sized for body habitus, a condition referred to as patient-prosthesis mismatch (PPM). The physiologic changes of pregnancy as well as the increased weight gain combine to exacerbate PPM. We report a case of PPM th...

  20. A custom-made temporomandibular joint prosthesis for fabrication by selective laser melting: Finite element analysis.

    Science.gov (United States)

    Xu, Xiangliang; Luo, Danmei; Guo, Chuanbin; Rong, Qiguo

    2017-08-01

    A novel and custom-made selective laser melting (SLM) 3D-printed alloplastic temporomandibular joint (TMJ) prosthesis is proposed. The titanium-6aluminium-4vanadium (Ti-6Al-4V) condyle component and ultra-high molecular weight polyethylene (UHMWPE) fossa component comprised the total alloplastic TMJ replacement prosthesis. For the condyle component, an optimized tetrahedral open-porous scaffold with combined connection structures, i.e. an inlay rod and an onlay plate, between the prosthesis and remaining mandible was designed. The trajectory of movement of the intact condyle was assessed via kinematic analysis to facilitate the design of the fossa component. The behaviours of the intact mandible and mandible with the prosthesis were compared. The biomechanical behaviour was analysed by assessing the stress distribution on the prosthesis and strain distribution on the mandible. After muscle force was applied, the magnitude of the compressive strain on the condyle neck of the mandible with the prosthesis was lower than that on the condyle neck of the intact mandible, with the exception of the area about the screws; additionally, the magnitude of the strain at the scaffold-bone interface was relatively high. Copyright © 2017. Published by Elsevier Ltd.

  1. Elektra prosthesis for trapeziometacarpal osteoarthritis

    DEFF Research Database (Denmark)

    Klahn, A; Nygaard, Mads; Gvozdenovic, R

    2012-01-01

    We present a prospective follow-up of 39 Elektra prostheses in 37 patients (32 women and five men), with a mean age of 56.5 (range 46-71) years; 34 patients had osteoarthritis and three had rheumatoid arthritis. Patients were followed using clinical examination, including measurement of pain...... be the key problem in treating trapeziometacarpal osteoarthritis using a total prosthesis....

  2. A unique method of retaining orbital prosthesis with attachment systems - a clinical report.

    Science.gov (United States)

    Guttal, Satyabodh S; Akash, N R; Prithviraj, D R; Lekha, K

    2014-06-01

    Diminution of the orbital contents post-surgical removal of a malignant tumor can have a severe psychological impact on the patient in terms of function and esthetics. Therefore, esthetic remedy should be planned subsequently, since tumor obliteration precedes cosmetic concern. A convenient option for successful rehabilitation in such patients is a simple, user-friendly, removable orbital prosthesis. Retention of the prosthesis is one of the key factors for the successful rehabilitation. Spectacle frame, conformers, adhesives, osseointegrated implants, magnets or buttons have been used to impart retention to the prosthesis. The use of semi precision attachments in maxillofacial prostheses is limited to the osseointegrated prostheses. This case report describes a conventional spectacle frame technique, to retain the silicone orbital prosthesis using two different types of stud attachments viz., dalla bona and O-ring attachment systems. Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  3. Customization of stock eye prosthesis for a pediatric patient by a simplified technique.

    Science.gov (United States)

    Jurel, Sunit Kumar; Talwar, Naina; Chand, Pooran; Singh, Raghuwar D; Gupta, Durga Shanker

    2012-05-01

    The unfortunate loss or absence of an eye may be caused by congenital defect , irreparable trauma, tumor or blind eye. The role of the maxillofacial prosthodontist in fabricating an ocular prosthesis to restore facial symmetry and normal appearance for the anophthalmic patient becomes essential. A custom-made ocular prosthesis is an excellent alternative for the people who lose their eye especially in young age. It has acceptable fit, retention and esthetics but is technically difficult to fabricate. On the other hand the stock eye has compromised fit and poor esthetics. Our case report presents a simple technique of customization of stock eye prosthesis to provide accurate fit and acceptable esthetics. How to cite this article: Jurel SK, Talwar N, Chand P, Singh RD, Gupta DS. Customization of Stock Eye Prosthesis for a Pediatric Patient by a Simplified Technique. Int J Clin Pediatr Dent 2012;5(2):155-158.

  4. Difference in occurrence of heterotopic ossification according to prosthesis type in the cervical artificial disc replacement.

    Science.gov (United States)

    Yi, Seong; Kim, Keung Nyun; Yang, Moon Sul; Yang, Joong Won; Kim, Hoon; Ha, Yoon; Yoon, Do Heum; Shin, Hyun Chul

    2010-07-15

    Retrospective study of the difference of heterotopic ossification (HO) occurrence according to 3 different types of prosthesis. This study was designed to investigate the difference of HO occurrence according to different type of prosthesis. HO is defined as formation of the bone outside the skeletal system. Reported HO occurrence rate in cervical artificial disc replacement (ADR) was unexpectedly high and varied. But the influencing factors of HO in cervical ADR have not been elucidated well. The prosthesis-related factors for making difference of HO occurrence were investigated in this study. A total of 170 patients undergoing cervical arthroplasty with the Bryan cervical disc prosthesis (Medtroic Sofamor Danek, Memphis, TN), Mobi-C disc prosthesis (LDR Medical, Troyes, France), and ProDisc-C (Synthes, Inc., West Chester, PA) were included. Cervical lateral radiographs obtained before and after surgery were used to identify HO. Occurrence rate, occurrence-free period, location, and grade of HOs were investigated according to the different prosthesis. Each prosthesis group included patients as follows: Bryan disc, 81 patients; Mobi-C, 61 patients; and ProDisc-C, 28 patients. Overall HO rate was 40.6% (69 of 170 patients). Each HO occurrence rate by prosthesis was as follows: the Bryan disc group, 21.0%; Mobi-C group, 52.5%; and the ProDisc-C group, 71.4%. In the survival analysis, all patients showed 27.1 +/- 3.7 months as the median survival. The Bryan disc group showed statistically longer survival (48.4 +/- 7.4 months) than the other groups. Occurrence of HO is an inevitable postoperative complication after cervical ADR. The occurrence rate of HO was higher than our expectation. Moreover, definite differences in occurrence rate according to the prosthesis type were identified by this study.

  5. Influence of type of aortic valve prosthesis on coronary blood flow velocity.

    Science.gov (United States)

    Jelenc, Matija; Juvan, Katja Ažman; Medvešček, Nadja Tatjana Ružič; Geršak, Borut

    2013-02-01

    Severe aortic valve stenosis is associated with high resting and reduced hyperemic coronary blood flow. Coronary blood flow increases after aortic valve replacement (AVR); however, the increase depends on the type of prosthesis used. The present study investigates the influence of type of aortic valve prosthesis on coronary blood flow velocity. The blood flow velocity in the left anterior descending coronary artery (LAD) and the right coronary artery (RCA) was measured intraoperatively before and after AVR with a stentless bioprosthesis (Sorin Freedom Solo; n = 11) or a bileaflet mechanical prosthesis (St. Jude Medical Regent; n = 11). Measurements were made with an X-Plore epicardial Doppler probe (Medistim, Oslo, Norway) following induction of hyperemia with an adenosine infusion. Preoperative and postoperative echocardiography evaluations were used to assess valvular and ventricular function. Velocity time integrals (VTI) were measured from the Doppler signals and used to calculate the proportion of systolic VTI (SF), diastolic VTI (DF), and normalized systolic coronary blood flow velocities (NSF) and normalized diastolic coronary blood flow velocities (NDF). The systolic proportion of the LAD VTI increased after AVR with the St. Jude Medical Regent prosthesis, which produced higher LAD SF and NSF values than the Sorin Freedom Solo prosthesis (SF, 0.41 ± 0.09 versus 0.29 ± 0.13 [P = .04]; NSF, 0.88 ± 0.24 versus 0.55 ± 0.17 [P = .01]). No significant changes in the LAD velocity profile were noted after valve replacement with the Sorin Freedom Solo, despite a significant reduction in transvalvular gradient and an increase in the effective orifice area. AVR had no effect on the RCA flow velocity profile. The coronary flow velocity profile in the LAD was significantly influenced by the type of aortic valve prosthesis used. The differences in the LAD velocity profile probably reflect differences in valve design and the systolic transvalvular flow pattern.

  6. Self and partner satisfaction rates after 3 part inflatable penile prosthesis implantation

    Directory of Open Access Journals (Sweden)

    Abdulmuttalip Simsek

    2014-09-01

    Full Text Available Objective: To evaluate and present satisfaction rates of our patients and their partners after 3 part inflatable penile prosthesis implantation. Materials and methods: We searched our hospital electronic data for patients who underwent inflatable penile prosthesis implantation between January 2008 and July 2013. Computer and archived file data were used to get information and reach the patients. We made telephone calls to patients and asked questionnaires about self and partner satisfaction rates. Results: 36 patients underwent prosthesis implantation during the 5 year period. We were able to reach by telephone call 18 of them. The mean age of 18 patients was 55.7 ± 9.4 years and mean body mass index was 24.6 ± 2.1 kg/m2. The etiology was diabetes mellitus on 14 (77.8% and radical pelvic surgery on 4 (22.2% patients. 14 of 18 patients had penile Doppler ultrasound test. Doppler ultrasound demonstrated venous insufficiency in 8 and arterial insufficiency in 6 patients. Mean time from implantation to study was 20.8 ± 13.9 months. Out of 18 patients 2 had prosthesis removal operation because of infection in one patient and perforation in the other. Satisfaction rate was 88.9%, and recommendation rate was 94.4%. Causes of dissatisfaction were pain in one patient and insufficient rigidity plus shortening of the penis in the other one. Partner satisfaction rate was 94.4%. Conclusion: Penile Prosthesis Implantation (PPI is the gold standard treatment of erectile dysfunction (ED irresponsive to medical treatment. Infection and mechanical failure rates are going to be less according to the improvements in synthetic materials and coverings of the prosthesis, so patient and partner satisfaction rates will be higher.

  7. Total shoulder replacement in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Sneppen, O; Fruensgaard, S; Johannsen, Hans Viggo

    1996-01-01

    A prospective study of 62 Neer mark II total shoulder arthroplasties performed during the period from 1981 to 1990 on 51 patients with rheumatoid arthritis was undertaken to evaluate factors associated with component loosening and proximal humeral migration. Thirty-two (51%) showed proximal......, range of movement, abduction force, or function. The risk of clinical asymptomatic loosening is a relatively late complication that is eventually followed by pronounced bone destruction related to the loose component. Long-term radiographic control of total shoulders with rheumatoid arthritis...... is recommended. Hemiarthroplasty with a cemented humeral prosthesis may be a better treatment in the end stage of rheumatoid arthritis of the shoulder....

  8. Hip arthroplasty. Part 1: prosthesis terminology and classification

    International Nuclear Information System (INIS)

    Pluot, E.; Davis, E.T.; Revell, M.; Davies, A.M.; James, S.L.J.

    2009-01-01

    Hip arthroplasty is an extremely common orthopaedic procedure and there is a wide array of implants that are in current use in the UK. The follow-up of patients who have undergone insertion of a hip prosthesis is shifting from a consultant-lead hospital service towards primary care. As this change in patient care continues it becomes increasingly important that an accurate description of the radiographic features is communicated to the primary-care practitioner so appropriate specialist input can be triggered. This review focuses on the terminology and classification of hip prostheses. This acts as a precursor for Part 2 of this series, which describes the normal and abnormal radiographic findings following hip prosthesis insertion.

  9. A Biomimetic Approach for Designing a Full External Breast Prosthesis: Post-Mastectomy

    Directory of Open Access Journals (Sweden)

    Pedro Cruz

    2018-03-01

    Full Text Available This work presents the design of a new breast prosthesis using the biomimetic technique for cases of complete mastectomy to address the problem of the increasing number of women diagnosed with breast cancer in Mexico who are candidates for a mastectomy. The designed prosthesis considers the morphology of a real breast regarding its internal structure to obtain authentic mobility and feel. In order to accomplish this, a model was obtained in 3D CAD using a coordinate measuring machine (CMM that can be scalable without losing its qualities, and which can be used in any type of patient; afterwards, a finite element model was developed and a static analysis performed with suggested load cases to evaluate the sensitivity and naturalness of the prosthesis; and finally, a modal analysis was conducted. The results obtained in displacements and in distribution of stress for the load cases assessed are consistent with those of a real breast: there were smooth contours and there was natural mobility in the prosthesis designed by means of the biomimetic technique.

  10. 21 CFR 888.3565 - Knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellofemorotibial metal/polymer... Devices § 888.3565 Knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis. (a) Identification. A knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis is a device...

  11. 21 CFR 888.3550 - Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellofemorotibial polymer/metal/metal... § 888.3550 Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis. (a) Identification. A knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis is a device...

  12. 21 CFR 888.3490 - Knee joint femorotibial metal/composite non-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/composite non... § 888.3490 Knee joint femorotibial metal/composite non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/composite non-constrained cemented prosthesis is a device...

  13. Assessment and management of chronic pain in patients with stable total hip arthroplasty

    OpenAIRE

    Classen, Tim; Zaps, Daniela; Landgraeber, Stefan; Li, Xinning; Jäger, Marcus

    2012-01-01

    Total hip arthroplasty (THA) is one of the most successful operations that can restore function and relieve pain. Although a majority of the patients achieve significant pain relief after THA, there are a number of patients that develop chronic pain for unknown reasons. A literature search was performed looking for chronic pain after total hip arthroplasty and stable THA. Major causes of chronic pain include aseptic loosening or infection. However, there is a subset of patients with a stable ...

  14. Fixation method does not affect restoration of rotation center in hip replacements: A single-site retrospective study

    OpenAIRE

    Wegner, Alexander; Kauther, Max Daniel; Landgraeber, Stefan; von Knoch, Marius

    2012-01-01

    Abstract Background Aseptic loosening is one of the greatest problems in hip replacement surgery. The rotation center of the hip is believed to influence the longevity of fixation. The aim of this study was to compare the influence of cemented and cementless cup fixation techniques on the position of the center of rotation because cemented cup fixation requires the removal of more bone for solid fixation than the cementless technique. Methods We retrospectively compared pre- and post-operativ...

  15. Does cement mantle thickness really matter?

    OpenAIRE

    Caruana, J.

    2008-01-01

    The thickness of the cement mantle around the femoral component of total hip replacements is a contributing factor to aseptic loosening and revision. Nevertheless, various designs of stems and surgical tooling lead to cement mantles of differing thicknesses. This thesis is concerned with variability in cement thickness around the Stanmore Hip, due to surgical approach, broach size and stem orientation, and its effects on stress and cracking in the cement. The extent to which cement mantle thi...

  16. Migration of the Duraloc cup after 5 years.

    Science.gov (United States)

    Stihsen, Christoph; Pabinger, Christof; Radl, Roman; Rehak, Peter; Windhager, Reinhard

    2008-12-01

    The Duraloc cup is a frequently used metal-backed, porous-coated, hemispherical, press-fit acetabular component. Published data on loosening rates are contradictory. In this study we investigated migration patterns with computer-assisted Einzel-Bild-Roentgen-Analyse (EBRA) of 67 Duraloc 100 cups. Cup migration and clinical scores were analysed over a 5-year follow-up period. Median total migration of the Duraloc 100 cup was 1.21 mm at 5 years. Seventy-five percent of implants were radiologically stable at 2 years and 90% at 4 years. One cup loosened aseptically at 60 months, requiring revision. Cup diameters > or = 54 mm migrated significantly more than cups < 54 mm in diameter (p = 0.029 at 4 years). There was a significant correlation between high polyethylene wear and further migrating cups within the first post-operative year (p = 0.035 at 12 months). Our analysis revealed significantly higher wear in males (p = 0.029 at 4 years). Radiological loosening at two years could be calculated using receiver-operating characteristic curve analysis, and 1.2 mm as an adequate threshold value (sensitivity = 100%, specificity = 89%).

  17. A case of aseptic vertebral necrosis in the context of metastatic lumbar disease

    International Nuclear Information System (INIS)

    Panow, C.; Valavanis, A.

    2002-01-01

    Aseptic bone necrosis has many well recognized etiologies: caisson disease, corticosteroids, alcohol, Gaucher's disease and sickle cell anemia being a few of a long list. Little attention has been paid to metastatic disease as a possible cause and we were unable to find reference in the literature to this association. We present imaging features of metastatic Ewing's sarcoma involving the vertebral spine, which, in certain aspects, mimics other well-known entities of this region, such as Kuemmell's and Scheuermann's diseases. (orig.)

  18. Eliciting Naturalistic Cortical Responses with a Sensory Prosthesis via Optimized Microstimulation

    Science.gov (United States)

    2016-08-12

    Eliciting naturalistic cortical responses with a sensory prosthesis via optimized microstimulation John S Choi1, Austin J Brockmeier2, David B...applied to single electrodes in the ventral caudal thalamus evoke percepts that are both place and modality-specific, and yet ‘unnatural’ in feeling ...information on touch parameters, they do so with the same timing, as would be expected for a biomimetic sensory prosthesis . The discriminability of natural

  19. Restoring Proprioception via a Cortical Prosthesis: A Novel Learning Based Approach

    Science.gov (United States)

    2016-10-01

    AWARD NUMBER: W81XWH-14-1-0510 TITLE: Restoring Proprioception via a Cortical Prosthesis : A Novel Learning-Based Approach PRINCIPAL INVESTIGATOR...Sep 2015 - 29 Sep 2016 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Restoring Proprioception via a Cortical Prosthesis : A Novel Learning-Based...the feeling of where the body is in space. The importance of proprioception is often not appreciated; without it, we are unable to move normally

  20. An experimental-numerical method for comparative analysis of joint prosthesis

    International Nuclear Information System (INIS)

    Claramunt, R.; Rincon, E.; Zubizarreta, V.; Ros, A.

    2001-01-01

    The difficulty that exists in the analysis of mechanical stresses in bones is high due to its complex mechanical and morphological characteristics. This complexity makes generalists modelling and conclusions derived from prototype tests very questionable. In this article a relatively simple comparative analysis systematic method that allow us to establish some behaviour differences in different kind of prosthesis is presented. The method, applicable in principle to any joint problem, is based on analysing perturbations produced in natural stress states of a bone after insertion of a joint prosthesis and combines numerical analysis using a 3-D finite element model and experimental studies based on photoelastic coating and electric extensometry. The experimental method is applied to compare two total hip prosthesis cement-free femoral stems of different philosophy. One anatomic of new generation, being of oblique setting over cancellous bone and the other madreporique of trochantero-diaphyseal support over cortical bone. (Author) 4 refs

  1. 21 CFR 888.3530 - Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/polymer semi... § 888.3530 Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer semi-constrained cemented prosthesis is a device intended...

  2. 21 CFR 888.3540 - Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellofemoral polymer/metal semi... § 888.3540 Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis. (a) Identification. A knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis is a two-part...

  3. 21 CFR 888.3500 - Knee joint femorotibial metal/composite semi-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/composite semi... § 888.3500 Knee joint femorotibial metal/composite semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/composite semi-constrained cemented prosthesis is a two-part...

  4. 21 CFR 888.3590 - Knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint tibial (hemi-knee) metallic resurfacing... Knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis. (a) Identification. A knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis is a device intended to be implanted...

  5. 21 CFR 888.3520 - Knee joint femorotibial metal/polymer non-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/polymer non... § 888.3520 Knee joint femorotibial metal/polymer non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer non-constrained cemented prosthesis is a device intended to...

  6. 21 CFR 888.3580 - Knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellar (hemi-knee) metallic... § 888.3580 Knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis. (a) Identification. A knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis is a device made of...

  7. Prevention of wear particle-induced osteolysis by a novel V-ATPase inhibitor saliphenylhalamide through inhibition of osteoclast bone resorption.

    Directory of Open Access Journals (Sweden)

    An Qin

    Full Text Available Wear particle-induced peri-implant loosening (Aseptic prosthetic loosening is one of the most common causes of total joint arthroplasty. It is well established that extensive bone destruction (osteolysis by osteoclasts is responsible for wear particle-induced peri-implant loosening. Thus, inhibition of osteoclastic bone resorption should prevent wear particle induced osteolysis and may serve as a potential therapeutic avenue for prosthetic loosening. Here, we demonstrate for the first time that saliphenylhalamide, a new V-ATPase inhibitor attenuates wear particle-induced osteolysis in a mouse calvarial model. In vitro biochemical and morphological assays revealed that the inhibition of osteolysis is partially attributed to a disruption in osteoclast acidification and polarization, both a prerequisite for osteoclast bone resorption. Interestingly, the V-ATPase inhibitor also impaired osteoclast differentiation via the inhibition of RANKL-induced NF-κB and ERK signaling pathways. In conclusion, we showed that saliphenylhalamide affected multiple physiological processes including osteoclast differentiation, acidification and polarization, leading to inhibition of osteoclast bone resorption in vitro and wear particle-induced osteolysis in vivo. The results of the study provide proof that the new generation V-ATPase inhibitors, such as saliphenylhalamide, are potential anti-resorptive agents for treatment of peri-implant osteolysis.

  8. [Phonomechanocardiography in the evaluation of the functional status of valvular prosthesis].

    Science.gov (United States)

    Esquivel Avila, J; Molina Zapata, B; Martínez Ríos, M A; Flamand, E

    1975-01-01

    The FMCG in 22 patients with valvular prosthesis is analyzed and its clinical, hemodynamic and surgical correlation are established (11 from the I.N.C. and 11 from the Hospital Infantil I.M.A.N.). The average age of the patients was 15 years old, 18 had a mitral and six aortic valvulopathy, and they all required a valvular replacement. Of the mitral prosthesis, 14 were Starr-Edwards (13 of ball valve and one of disc), three Lillehei-Kaster and one Börck-Shiley. In 5 patients, the FMCG suspected disfunction that was later corroborated by catheterism in three patients and by surgery in all of them. The important differences of the FMCG between the group with good and the one with bad function were: the aparition of a rumble, a decrease in the amplitud of the closing snap, index of closing snap opering snap of less than one, lenghtening of fases PFVP and IVCP, and shortening of IVDRP. In the patients with auricular fibrilation, after long dyastoles; that would represent an adequate atrial emptying; the closing snap was more intense, the PFVP was lennthened the IVDRP was shortened when the prosthesis was not properly functioning. All the aortic prosthesis were ball valve Starr-Edwards type; in one the FMCG suspected disfunction and the patient had a sudden death outside of the Hospital. The significant differences of the FMCG were the decrease in the intensity of the opening snap, with a Hylen index of less than one, lengthening of the PFVP, IVCP and of the expulsive period (EP). The authors conclude that the FMCG is a good method for an early detection of the disfunctions of valvular prosthesis.

  9. Biosurfactant production using mixed cultures under non-aseptic conditions

    International Nuclear Information System (INIS)

    Vipulanandan, C.; Ghurye, G.L.; Willson, R.C.

    1994-01-01

    The use of surfactants is of increasing interest for remediation of petroleum hydrocarbons in groundwater and soil. Surfactants increase the accessibility of adsorbed hydrocarbons and mobilize immiscible petroleum hydrocarbons for treatment. Biosurfactants have the advantage of biodegradability and non-toxicity over their synthetic counterparts, and can be produced from renewable sources. In this study the production of biosurfactant from molasses was investigated in continuously stirred batch reactors. The effects of substrate concentration, yeast extract and peptone on biomass accumulation and biosurfactant production were investigated. Biosurfactant production was quantified by surface tension reduction and critical micelle dilution (CMD). Biosurfactant production was directly correlated with biomass production, and was improved with the addition of yeast extract. Centrifugation of the whole broth reduced surface tension. The performance of the biosurfactant produced from molasses under non-aseptic condition is comparable to other published results

  10. [Longterm results of cervical arthroplasty with disc prosthesis. A literature review].

    Science.gov (United States)

    Fransen, P; Schils, F

    2014-01-01

    Cervical arthroplasty has now been performed for over 10 years. Despite the large number of implanted artificial discs, the quality of the published studies is weak, and very few report a follow up exceeding two years. We reviewed the literature on cervical total disc replacement, focusing on publications reporting a follow-up of more than two years. The selection of patients, the type of implant and the surgical technique seem to influence greatly the quality of the clinical and radiological results. The occurrence of heterotopic ossifications around the implant seems to be the rule rather than the exception. Wear debris are likely to be observed in the vicinity of the prosthesis. Most long term studies also report a progressive decrease in the range of motion of the prosthesis, although without influence on the clinical evolution. It seems reasonable to say that cervical disc prosthesis is not inferior to discectomy and fusion, and that these implants allow a short term preservation of cervical mobility, but the efficacy in preventing adjacent segment disease or a favourable costleffectiveness ratio have yet to be demonstrated. A more widespread use of cervical disc prosthesis can only be suggested when these questions have been answered by long term follow-up studies.

  11. Quality of life among lower limb prosthesis users attending Artificial Limb Center of Fauji Foundation Hospital Rawalpindi

    International Nuclear Information System (INIS)

    Kalsoom, U.; Bairam, S.

    2018-01-01

    To assess quality of life and the influencing factors as perceived by lower limb prosthesis users. Study Design: Cross sectional study. Place and Duration of Study: Artificial Limb Centre, Fauji Foundation Hospital Rawalpindi, 11 months (Jan to Nov 2014). Material and Methods: A sample of 50 patients with lower limb amputations and using lower limb prosthesis were recruited by applying inclusion criteria. Responses were recorded on demographic variables, reasons for amputation, time of provision of prosthesis, employment status etc. by the investigator on a structured pretested questionnaire after their consent. A p-value of <0.05 was taken as significant. Quality of life was interpreted on 5 point Likert scale. Data was analyzed in SPSS version 21. Result: Majority of respondents i.e. 17 (34%) were in 51-60 years age group with mean age 46 +- 14 years while 33 (66%) were males and 27 (54%) illiterate, 33 (66%) could afford a prosthesis. Trauma 28 (56%) was the most prevalent cause of lower limb amputation and among them 15 (53%) had road accident injuries. Various factors influenced quality of life as perceived by the respondents and in 10 (20%), 16 (32%), 25 (50%) social, family life and emotional status was affected respectively, while 14 (28%) of the prosthesis user were unemployed. Prosthesis were provided after 2 years in 18 (36%) and in 37 (74%) prosthesis were provided by the health care facility. Good quality of life was perceived in 40 (80%) respondents. Conclusion: Perceived Quality of life was good in majority of the prosthesis users but others can't be ignored. It can be improved by early provision of prosthesis which can help in better employment opportunities. (author)

  12. Experimental Assessment of a New Type of Carbon-Coated ARTECOR® Vascular Prosthesis in Sheep

    Directory of Open Access Journals (Sweden)

    Jiří Podlaha

    2009-01-01

    Full Text Available The aim of the study was to test and verify the characteristics of a new type of carbon-coated ARTECOR® vascular prosthesis developed at the Knitting Research Institute, a.s. Brno. Eight healthy Merino sheep, aged between 2 and 3 years, were implanted four types (A, B, C with diamond-like carbon (DLC coating and D as a control without DLC of vascular prostheses. The site of implantation was the common carotid artery; the length of the implant was 7 cm. All sheep received antibiotics prophylactically in accordance with the theory of the so-called “protected coagulum”. Doppler ultrasound examination was performed before finishing the operation to verify the patency of each prosthesis. During the study period the animals were closely observed. Prostheses were extirpated on day +/- 100 in 6 sheep and on day 182 in 2 sheep. Type B prosthesis showed better results according to its postoperative patency. The implant lumen was constantly 7 mm, whereas the use of other types resulted in lumen narrowing. Type B prosthesis has a deposition of DLC coating of a thickness of 20 nm with a high content of sp3 bonds (more diamond-like ones. The experimental type B of prosthesis ARTECOR® appears to be the most successful of the tested prostheses (at the end of the study all B-type prostheses remained patent. This prosthesis appears to better satisfy the rheologic characteristics for healing.

  13. Periprosthetic fracture-dislocation in a loosened total knee replacement treated by knee arthrodesis

    International Nuclear Information System (INIS)

    Lozano Moreno, Francisco Jose

    2004-01-01

    We present a patient who was operated four years before performing a total knee replacement. She fell down resulting a periprosthetic femoral fracture and a prosthetic dislocation. After evaluating different treatments, we decided to do prosthetic removal and a knee arthrodesis using an intramedullar nail. The femoral fracture was fixed with wire cerclages. Knee arthrodesis is a procedure uses as a last option for the treatment of infected or loosed arthroplasties. In our case it was difficult to consider any other reconstructive procedure due to the association of fracture, dislocation and loosening. The evolution has been satisfactory with good functional result and without pain

  14. Restoring Proprioception via a Cortical Prosthesis: A Novel Learning-Based Approach

    Science.gov (United States)

    2015-10-01

    AWARD NUMBER: W81XWH-14-1-0510 TITLE: Restoring Proprioception via a Cortical Prosthesis : A Novel Learning-Based Approach PRINCIPAL INVESTIGATOR...Proprioception via a Cortical Prosthesis : A Novel Learning-Based Approach 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Philip Sabes, PhD 5d...component of this lost sensation is proprioception, the feeling of where the body is in space. The importance of proprioception is often not appreciated

  15. Clinical experience with an alloplastic stoma prosthesis (Biocarbon) for urinary conduits and cutaneous ureterostomy.

    Science.gov (United States)

    Månsson, W; Harzmann, R

    1988-01-01

    An alloplastic stoma prosthesis, Biocarbon, composed of 99.9% pure carbon in vitreous form, was used in six patients with conduit urinary diversion and in seven with cutaneous ureterostomy. The patients were thereafter observed for 2-86 months. Complications were subcutaneous infection, urinary fistula and ureteral stenosis, which necessitated removal of the prosthesis in most cases. The permanent stoma, without need for adhesive collecting device, was appreciated by the patients. Problems relating to biocompatibility remain to be solved before the place of the stoma prosthesis in urinary diversion can be determined.

  16. No demonstrable association between the Leningrad-Zagreb mumps vaccine strain and aseptic meningitis in a large clinical trial in Egypt.

    Science.gov (United States)

    Sharma, H J; Oun, S Aly; Bakr, S S Abou; Kapre, S V; Jadhav, S S; Dhere, R M; Bhardwaj, S

    2010-04-01

    To address the claim that the Leningrad-Zagreb (L-Z) mumps vaccine strain is causally associated with aseptic meningitis, a prospective, post-marketing safety study was conducted with a measles-mumps-rubella vaccine (MMR) (TRESIVAC(R); Serum Institute of India Ltd., Pune, India), which uses the L-Z strain as its mumps component in Egypt. In all, 453 119 children (65 423 children aged 16-24 months and 329 211 children aged 5-7 years) received MMR. The control groups which, as a result of local health regulations, were slightly younger than vaccinees, comprised 12 253 and 46 232 children, respectively. Using questionnaires, the parents recorded solicited local, systemic and neurological adverse events for up to 42 days post-vaccination. All data were analysed externally on an intention-to-treat basis by individuals not participating in the study. Local and/or systemic reactions were reported in a small percentage of participants, with pain, fever and parotitis being the most common signs among vaccinees in both age groups. No case of aseptic meningitis, encephalitis, anaphylaxis or convulsions was observed in any participant. Thus, in this series of more than 450 000 Egyptian children, the L-Z mumps vaccine strain in this vaccine did not cause aseptic meningitis. The vaccine is considerably cheaper than Western competitors and a valid alternative to other MMR vaccines.

  17. Dual Action of Lysophosphatidate-Functionalised Titanium: Interactions with Human (MG63 Osteoblasts and Methicillin Resistant Staphylococcus aureus.

    Directory of Open Access Journals (Sweden)

    Mette Elena Skindersoe

    Full Text Available Titanium (Ti is a widely used material for surgical implants; total joint replacements (TJRs, screws and plates for fixing bones and dental implants are forged from Ti. Whilst Ti integrates well into host tissue approximately 10% of TJRs will fail in the lifetime of the patient through a process known as aseptic loosening. These failures necessitate revision arthroplasties which are more complicated and costly than the initial procedure. Finding ways of enhancing early (osseointegration of TJRs is therefore highly desirable and continues to represent a research priority in current biomaterial design. One way of realising improvements in implant quality is to coat the Ti surface with small biological agents known to support human osteoblast formation and maturation at Ti surfaces. Lysophosphatidic acid (LPA and certain LPA analogues offer potential solutions as Ti coatings in reducing aseptic loosening. Herein we present evidence for the successful bio-functionalisation of Ti using LPA. This modified Ti surface heightened the maturation of human osteoblasts, as supported by increased expression of alkaline phosphatase. These functionalised surfaces also deterred the attachment and growth of Staphylococcus aureus, a bacterium often associated with implant failures through sepsis. Collectively we provide evidence for the fabrication of a dual-action Ti surface finish, a highly desirable feature towards the development of next-generation implantable devices.

  18. Acetabular Reconstruction with the Burch-Schneider Antiprotrusio Cage and Bulk Allografts: Minimum 10-Year Follow-Up Results

    Directory of Open Access Journals (Sweden)

    Dario Regis

    2014-01-01

    Full Text Available Reconstruction of severe pelvic bone loss is a challenging problem in hip revision surgery. Between January 1992 and December 2000, 97 hips with periprosthetic osteolysis underwent acetabular revision using bulk allografts and the Burch-Schneider antiprotrusio cage (APC. Twenty-nine patients (32 implants died for unrelated causes without additional surgery. Sixty-five hips were available for clinical and radiographic assessment at an average follow-up of 14.6 years (range, 10.0 to 18.9 years. There were 16 male and 49 female patients, aged from 29 to 83 (median, 60 years, with Paprosky IIIA (27 cases and IIIB (38 cases acetabular bone defects. Nine cages required rerevision because of infection (3, aseptic loosening (5, and flange breakage (1. The average Harris hip score improved from 33.1 points preoperatively to 75.6 points at follow-up (P<0.001. Radiographically, graft incorporation and cage stability were detected in 48 and 52 hips, respectively. The cumulative survival rates at 18.9 years with removal for any reason or X-ray migration of the cage and aseptic or radiographic loosening as the end points were 80.0% and 84.6%, respectively. The use of the Burch-Schneider APC and massive allografts is an effective technique for the reconstructive treatment of extensive acetabular bone loss with long-lasting survival.

  19. Polyethylene and methyl methacrylate particle-stimulated inflammatory tissue and macrophages up-regulate bone resorption in a murine neonatal calvaria in vitro organ system.

    Science.gov (United States)

    Ren, Weiping; Wu, Bin; Mayton, Lois; Wooley, Paul H

    2002-09-01

    There is considerable evidence that orthopaedic wear debris plays a crucial role in the pathology of aseptic loosening of joint prostheses. This study examined the effect of inflammatory membranes stimulated with methyl methacrylate and polyethylene on bone resorption, using the murine air pouch model. The capacity of RAW 264.7 mouse macrophages exposed to polymer particles to produce factors affecting bone metabolism was also studied. Neonatal calvaria bones were co-cultured with either pouch membranes or conditioned media from activated macrophages. Bone resorption was measured by the release of calcium from cultured bones, and the activity of tartrate-resistant acid phosphatase in both bone sections and culture medium was also assayed. Results showed that inflammatory pouch membrane activated by methyl methacrylate and polyethylene enhanced osteoclastic bone resorption. Conditioned media from particles stimulated mouse macrophages also stimulated bone resorption, although this effect was weaker than resorption induced by inflammatory pouch membranes. The addition of the particles directly into the medium of cultured calvaria bones had little effect on bone resorption. Our observations indicate that both inflammatory tissue and macrophages provoked by particles can stimulate bone resorption in cultured mouse neonatal calvaria bones. This simple in vitro bone resorption system allows us to investigate the fundamental cellular and molecular mechanism of wear debris induced bone resorption and to screen potential therapeutic approaches for aseptic loosening.

  20. A cementless, proximally fixed anatomic femoral stem induces high micromotion with nontraumatic femoral avascular necrosis: A finite element study

    Directory of Open Access Journals (Sweden)

    Wen-Chuan Chen

    2014-07-01

    Full Text Available Decrease in bone mineral density of metaphysis in patients with nontraumatic avascular necrosis of the femoral head (AVN is considered the main factor leading to aseptic loosening of the femoral component. Researchers have hypothesized that a cementless, anatomic stem fixed proximally to the metaphysis has a higher risk for aseptic loosening than a straight stem that is fixed at the diaphysis in patients with nontraumatic AVN. The purpose of the current study was to evaluate the effects of cancellous bone stiffness at the metaphysis and stem geometry on the micromotion of the femoral stem relative to the femur. The VerSys (straight and ABG (anatomic femoral stems were enrolled in this finite element study to determine the performance of prosthetic micromotion. The simulated load to the hip joint during heel strike was assigned. Results showed that the VerSys model represented better resistance in micromotion between the bone/stem interface than the ABG model in either normal or poor cancellous bone stiffness at the metaphysis. The bone quality at the metaphysis of patients with nontraumatic AVN should be considered prior to selecting a femoral stem. In consideration of initial stability, acementless, straight stem that fits the isthmus is more favourable than an anatomic stem that is fixed to the proximal area of the canal.

  1. The unsuspected prosthetic joint infection : incidence and consequences of positive intra-operative cultures in presumed aseptic knee and hip revisions.

    Science.gov (United States)

    Jacobs, A M E; Bénard, M; Meis, J F; van Hellemondt, G; Goosen, J H M

    2017-11-01

    Positive cultures are not uncommon in cases of revision total knee and hip arthroplasty (TKA and THA) for presumed aseptic causes. The purpose of this study was to assess the incidence of positive intra-operative cultures in presumed aseptic revision of TKA and THA, and to determine whether the presence of intra-operative positive cultures results in inferior survival in such cases. A retrospective cohort study was assembled with 679 patients undergoing revision knee (340 cases) or hip arthroplasty (339 cases) for presumed aseptic causes. For all patients three or more separate intra-operative cultures were obtained. Patients were diagnosed with a previously unsuspected prosthetic joint infection (PJI) if two or more cultures were positive with the same organism. Records were reviewed for demographic details, pre-operative laboratory results and culture results. The primary outcome measure was infection-free implant survival at two years. The incidence of unsuspected PJI was 27 out of 340 (7.9%) in TKA and 41 out of 339 (12.1%) in THA. Following revision TKA, the rate of infection-free implant survival in patients with an unsuspected PJI was 88% (95% confidence intervals (CI) 60 to 97) at two years compared with 98% (95% CI 94 to 99) in patients without PJI (p = 0.001). After THA, the rate of survival was similar in those with unsuspected PJI (92% (95% CI 73 to 98) at two years) and those without (94% (95% CI 89 to 97), p = 0.31). Following revision of TKA and THA for aseptic diagnoses, around 10% of cases were found to have positive cultures. In the knee, such cases had inferior infection-free survival at two years compared with those with negative cultures; there was no difference between the groups following THA. Cite this article: Bone Joint J 2017;99-B:1482-9. ©2017 The British Editorial Society of Bone & Joint Surgery.

  2. Effect of breast augmentation after breast-conserving surgery for breast cancer on radiation dose. Silicone prosthesis and changes in radiation dose

    International Nuclear Information System (INIS)

    Tonari, Ayako; Nako, Yasunobu; Ikezaki, Hiromi; Maruyama, Yasushi; Ikeda, Ikuo; Kusuda, Junko; Harii, Kiyonori; Takayama, Makoto

    2008-01-01

    The results of a study simulating postoperative radiation therapy of remaining breast tissue with a silicone bag prosthesis implanted to examine the effects of the prosthesis on radiation dosage and surrounding tissue are reported. The evaluation was conducted in two stages: a water phantom was used to evaluate scattering effects of a prosthesis installed inside the phantom using glass rod detector (GRD) set around the prosthesis. Measurements were conducted on both entrance and rear sides of the prosthesis. A Rand phantom was used to measure radiation doses around the prosthesis. The first evaluation resulted in a less than 5.4% reduction in dose at the rear side of the prosthesis whereas the second evaluation, for opposing portal irradiation used with breast-conserving surgical treatment, showed the effects of the prosthesis on radiation dosage being within ±2%, the permitted treatment range. In conclusion, for treating breast cancer, combining surgical treatment of the cancer with implanting of prosthesis for breast reconstruction followed by radiation treatment appears feasible as no effects on dosage were observed on treatment effectiveness. (author)

  3. A cognitive prosthesis for complex decision-making.

    Science.gov (United States)

    Tremblay, Sébastien; Gagnon, Jean-François; Lafond, Daniel; Hodgetts, Helen M; Doiron, Maxime; Jeuniaux, Patrick P J M H

    2017-01-01

    While simple heuristics can be ecologically rational and effective in naturalistic decision making contexts, complex situations require analytical decision making strategies, hypothesis-testing and learning. Sub-optimal decision strategies - using simplified as opposed to analytic decision rules - have been reported in domains such as healthcare, military operational planning, and government policy making. We investigate the potential of a computational toolkit called "IMAGE" to improve decision-making by developing structural knowledge and increasing understanding of complex situations. IMAGE is tested within the context of a complex military convoy management task through (a) interactive simulations, and (b) visualization and knowledge representation capabilities. We assess the usefulness of two versions of IMAGE (desktop and immersive) compared to a baseline. Results suggest that the prosthesis helped analysts in making better decisions, but failed to increase their structural knowledge about the situation once the cognitive prosthesis is removed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Stress distribution in dental prosthesis under an occlusal combined dynamic loading

    International Nuclear Information System (INIS)

    Merdji, A.; Bachir Bouiadjra, B.; Ould Chikh, B.; Mootanah, R.; Aminallah, L.; Serier, B.; Muslih, I.M.

    2012-01-01

    Highlights: ► The mechanical stress reaches the highest in areas of cortical bones. ► The mechanical stress in the cancellous bone reaches greatest in the bottom of the dental implant. ► Implant with low-volume bone might cause increased stress concentration in the cortical bone. -- Abstract: The biomechanical behavior of osseointegrated dental prostheses systems plays an important role in its functional longevity inside the bone. Simulation of these systems requires an accurate modeling of the prosthesis components, the jaw bone, the implant–bone interface, and the response of the system to different types of applied forces. The purpose of this study was to develop a new three-dimensional model of an osseointegrated molar dental prosthesis and to carry out finite element analysis to evaluate stress distributions in the bone and the dental prosthesis compounds under an occlusal combined dynamic load was applied to the top of the occlusale face of the prosthesis crown. The jaw bone model containing cortical bone and cancellous bone was constructed by using computer tomography scan pictures and Computer Aided Design tools. The dental prosthesis compounds were constructed, simulating the commercially available cylindrical implant of 4.8 mm diameter and 10 mm length. Both finite element models were created in Abaqus finite element software. All materials used in the models were considered to be isotropic, homogeneous and linearly elastic. The elastic properties, loads and constraints used in the model were taken from published data. Results of our finite element analyses, indicated that the maximum stresses were located around the mesial neck of the implant, in the marginal bone. Thus, this area should be preserved clinically in order to maintain the bone–implant interface structurally and functionally.

  5. A simplified approach to fabrication of an ocular prosthesis: A case series

    Directory of Open Access Journals (Sweden)

    Kaur Amandeep

    2010-01-01

    Full Text Available The eye is a vital organ and an important component of facial expression. Loss of an eye has a crippling effect on the psychology of the patient. Enucleation of the eye is therefore normally followed by fabrication of an ocular prosthesis to improve esthetics. A less complex technique for fabrication of an ocular prosthesis is described in this report of two different cases.

  6. Visual prosthesis wireless energy transfer system optimal modeling.

    Science.gov (United States)

    Li, Xueping; Yang, Yuan; Gao, Yong

    2014-01-16

    Wireless energy transfer system is an effective way to solve the visual prosthesis energy supply problems, theoretical modeling of the system is the prerequisite to do optimal energy transfer system design. On the basis of the ideal model of the wireless energy transfer system, according to visual prosthesis application condition, the system modeling is optimized. During the optimal modeling, taking planar spiral coils as the coupling devices between energy transmitter and receiver, the effect of the parasitic capacitance of the transfer coil is considered, and especially the concept of biological capacitance is proposed to consider the influence of biological tissue on the energy transfer efficiency, resulting in the optimal modeling's more accuracy for the actual application. The simulation data of the optimal model in this paper is compared with that of the previous ideal model, the results show that under high frequency condition, the parasitic capacitance of inductance and biological capacitance considered in the optimal model could have great impact on the wireless energy transfer system. The further comparison with the experimental data verifies the validity and accuracy of the optimal model proposed in this paper. The optimal model proposed in this paper has a higher theoretical guiding significance for the wireless energy transfer system's further research, and provide a more precise model reference for solving the power supply problem in visual prosthesis clinical application.

  7. False-positive indium-111 labeled leukocyte scintigram in a patient with a painful hip prosthesis

    International Nuclear Information System (INIS)

    Feldman, N.; Makler, P.T. Jr.; Alavi, A.

    1986-01-01

    A Tronzo hip prosthesis is designed to elicit an inflammatory reaction in order to promote prosthesis stability. A three-phased bone scan and Ga-67 imaging in conjunction with physical examination and laboratory findings failed to demonstrate evidence for osteomyelitis in a patient with a painful hip prosthesis, in whom images obtained with In-111-labeled leukocytes were positive. This observation demonstrated that the interpretation of the latter technique in demonstrating inflammation can cause a false impression of an infectious process

  8. Nontraumatic Fracture of the Femoral Condylar Prosthesis in a Total Knee Arthroplasty Leading to Mechanical Failure

    Directory of Open Access Journals (Sweden)

    Girish N. Swamy

    2014-01-01

    Full Text Available This paper reports a case of fatigue fracture of the femoral component in a cruciate-retaining cemented total knee arthroplasty (TKA. A 64-year-old man had undergone a primary TKA for osteoarthritis 10 years previously at another institution using the PFC-Sigma prosthesis. The patient recovered fully and was back to his regular activities. He presented with a history of sudden onset pain and locking of the left knee since the preceding three months. There was no history of trauma, and the patient was mobilizing with difficulty using crutches. Radiographs revealed fracture of the posterior condyle of the femoral prosthesis. Revision surgery was performed as an elective procedure revealing the broken prosthesis. The TC3RP-PFC revision prosthesis was used with a medial parapatellar approach. The patient recovered fully without any squeal. Mechanical failure of the knee arthroplasty prosthesis is rare, and nontraumatic fracture of the femoral metallic component has not been reported before.

  9. Nontraumatic fracture of the femoral condylar prosthesis in a total knee arthroplasty leading to mechanical failure.

    Science.gov (United States)

    Swamy, Girish N; Quah, Conal; Bagouri, Elmunzar; Badhe, Nitin P

    2014-01-01

    This paper reports a case of fatigue fracture of the femoral component in a cruciate-retaining cemented total knee arthroplasty (TKA). A 64-year-old man had undergone a primary TKA for osteoarthritis 10 years previously at another institution using the PFC-Sigma prosthesis. The patient recovered fully and was back to his regular activities. He presented with a history of sudden onset pain and locking of the left knee since the preceding three months. There was no history of trauma, and the patient was mobilizing with difficulty using crutches. Radiographs revealed fracture of the posterior condyle of the femoral prosthesis. Revision surgery was performed as an elective procedure revealing the broken prosthesis. The TC3RP-PFC revision prosthesis was used with a medial parapatellar approach. The patient recovered fully without any squeal. Mechanical failure of the knee arthroplasty prosthesis is rare, and nontraumatic fracture of the femoral metallic component has not been reported before.

  10. Development and performance of a new prosthesis system using ultrasonic sensor for wrist movements: a preliminary study

    Science.gov (United States)

    2014-01-01

    Background The design and performance of a new development prosthesis system known as biomechatronics wrist prosthesis is presented in this paper. The prosthesis system was implemented by replacing the Bowden tension cable of body powered prosthesis system using two ultrasonic sensors, two servo motors and microcontroller inside the prosthesis hand for transradial user. Methods The system components and hand prototypes involve the anthropometry, CAD design and prototyping, biomechatronics engineering together with the prosthetics. The modeler construction of the system develop allows the ultrasonic sensors that are placed on the shoulder to generate the wrist movement of the prosthesis. The kinematics of wrist movement, which are the pronation/supination and flexion/extension were tested using the motion analysis and general motion of human hand were compared. The study also evaluated the require degree of detection for the input of the ultrasonic sensor to generate the wrist movements. Results The values collected by the vicon motion analysis for biomechatronics prosthesis system were reliable to do the common tasks in daily life. The degree of the head needed to bend to give the full input wave was about 45° - 55° of rotation or about 14 cm – 16 cm. The biomechatronics wrist prosthesis gave higher degree of rotation to do the daily tasks but did not achieve the maximum degree of rotation. Conclusion The new development of using sensor and actuator in generating the wrist movements will be interesting for used list in medicine, robotics technology, rehabilitations, prosthetics and orthotics. PMID:24755242

  11. Osseointegrated silicone finger prosthesis using dental implants: a renovated technique.

    Science.gov (United States)

    Vinnakota, Dileep Nag; Sankar, V Vijay; Chirumamilla, Naveen; Reddy, V Vamsikrishna

    2014-11-01

    In clinical practice, we come across patients with traumatically amputated or congenitally missing partial or complete fingers that can be restored using microsurgical replantation or transplantation procedures. However, in some cases this might not be possible due to systemic or local factors and the lost or missing part has to be replaced prosthetically to offer psychological and functional wellbeing. These prostheses can be constructed with various materials like acrylics or silicone retained with the help of auxiliary aids. However, these prostheses cause some hindrance in performing functions like writing, typing, etc. The aim of the present trial was to ameliorate the existing design of implant supported finger prosthesis. Distal phalange of middle finger replaced with implant supported silicone finger prosthesis is modified by utilizing a metal framework to support silicone material to improve rigidity while working. We could achieve a good function, esthetics and tactile sensibility with this modified design. Whenever, feasible this design can improve the performance and patients feel a deep sense of satisfaction and improved self-esteem with this modified prosthesis.

  12. Malignant esophageal stenosis: treatment with the Wallsten ''TM prosthesis

    International Nuclear Information System (INIS)

    Paul, L.; Pinto, I.

    1998-01-01

    To discuss the technical aspects and adders the clinical results of treatment of malignant esophaged dysphagia by placement of a Wallstent prosthesis under fluoroscopic guidance. Over the past six years, we have implanted 63 Wallstent metallic prostheses in 40 patients with un operable malignant dysphagia of esophaged origin. The consisted of 36 men and 6 women with a mean age of 72 years. Seven of the neoplasms were associated with fistula.Six involved recurrent tumors at the point of the surgical anastomosis. Following implantation, the patients were evaluated clinically and radiologically at postoperative hour 48 and periodically thereafter until their death or until the study was completed in September 1996. The placement of the prostheses was achieved in all the patients. Immediate technical problems (malposition or failure to expand) in 27.5% of cases. Forty percent of the patients complained of plain, and there was one death due to massive hematemesis. A clear improvement in dysphagia was obtained was obtained in 79% of and only one of the 7 fistulas was closed. During follow-up, the main complication was obstruction of prosthesis (25%) as a result of tumor overgrowth (9 episodes in 8 patients) or due to food impaction (4 episodes in 3 patients). The rate of retreatment was 27.5%. The mean survival time after prosthesis implantation was 132 ±207 days and 62.5% of the devices were still permeable when the patient died. Implantation of Wallstent prosthesis in cases of malignant esophageal stenosis is easy and safe, and constitutes an effective treatment of dysphagia. Nevertheless, thorough knowledge of the technical aspects ensures better results and the strict assessment of the indications guarantees an improved cost-benefit ratio for this technique. (Author) 23 refs

  13. Iris reconstruction using artificial iris prosthesis for management of aniridia.

    Science.gov (United States)

    Mostafa, Yehia S; Osman, Amr A; Hassanein, Dina H; Zeid, Ashraf M; Sherif, Ahmed M

    2018-01-01

    To discuss the limitations and benefits of the BrightOcular prosthetic artificial iris device in management of aniridia associated with aphakia or cataract. This is a retrospective study including 5 eyes of 4 patients who underwent implantation of the BrightOcular iris prosthesis (Stellar Devices) for total or partial aniridia. The cases included 2 eyes of 1 patient with congenital aniridia associated with congenital cataract and 3 eyes with traumatic aniridia: 1 with subluxated cataractous lens and 2 with aphakia. In all cases, the iris prosthesis was implanted after a 3-piece acrylic intraocular lens was implanted. We evaluated the clinical course with a minimum follow-up period of 6 months, the intraoperative and postoperative complications, and the cosmetic satisfaction of patients. All patients had improved uncorrected distance visual acuity and best-corrected distance visual acuity. All patients had a transient corneal edema that resolved within the first postoperative week. Only the patient with congenital aniridia had a permanent increase in intraocular pressure and developed a band keratopathy throughout a 2-year follow-up period. The prosthesis was well-centered in all eyes except for one case that required scleral suture fixation after 3 months. All patients had a satisfactory cosmetic appearance. BrightOcular iris prosthesis is a safe and useful tool to correct aniridia associated with pseudophakia or aphakia. Being foldable, it is easy to be implanted through a small incision and placed in the ciliary sulcus without sutures when properly sized. Cosmetic results are satisfactory. Sizing methods should be improved.

  14. Case Report: Magnetically retained silicone facial prosthesis ...

    African Journals Online (AJOL)

    Prosthetic camouflaging of facial defects and use of silicone maxillofacial material are the alternatives to the surgical retreatment. Silicone elastomers provide more options to clinician for customization of the facial prosthesis which is simple, esthetically good when coupled with bio magnets for retention. Key words: Magnet ...

  15. Fusion around cervical disc prosthesis: case report.

    NARCIS (Netherlands)

    Bartels, R.H.M.A.; Donk, R.

    2005-01-01

    OBJECTIVE AND IMPORTANCE: Cervical arthroplasty is a relatively new method to maintain motion after cervical anterior discectomy. Two cases are presented in which bony fusion occurred around a cervical disc prosthesis. CLINICAL PRESENTATION: A 30-year-old man and a 49-year-old woman underwent a

  16. Conventional versus computer-navigated TKA: a prospective randomized study.

    Science.gov (United States)

    Todesca, Alessandro; Garro, Luca; Penna, Massimo; Bejui-Hugues, Jacques

    2017-06-01

    The purpose of this study was to assess the midterm results of total knee arthroplasty (TKA) implanted with a specific computer navigation system in a group of patients (NAV) and to assess the same prosthesis implanted with the conventional technique in another group (CON); we hypothesized that computer navigation surgery would improve implant alignment, functional scores and survival of the implant compared to the conventional technique. From 2008 to 2009, 225 patients were enrolled in the study and randomly assigned in CON and NAV groups; 240 consecutive mobile-bearing ultra-congruent score (Amplitude, Valence, France) TKAs were performed by a single surgeon, 117 using the conventional method and 123 using the computer-navigated approach. Clinical outcome assessment was based on the Knee Society Score (KSS), the Hospital for Special Surgery Knee Score and the Western Ontario Mac Master University Index score. Component survival was calculated by Kaplan-Meier analysis. Median follow-up was 6.4 years (range 6-7 years). Two patients were lost to follow-up. No differences were seen between the two groups in age, sex, BMI and side of implantation. Three patients of CON group referred feelings of instability during walking, but clinical tests were all negative. NAV group showed statistical significant better KSS Score and wider ROM and fewer outliers from neutral mechanical axis, lateral distal femoral angle, medial proximal tibial angle and tibial slope in post-operative radiographic assessment. There was one case of early post-operative superficial infection (caused by Staph. Aureus) successfully treated with antibiotics. No mechanical loosening, mobile-bearing dislocation or patellofemoral complication was seen. At 7 years of follow-up, component survival in relation to the risk of aseptic loosening or other complications was 100 %. There were no implant revisions. This study demonstrates superior accuracy in implant positioning and statistical significant

  17. Heterotopic ossification associated with myelopathy following cervical disc prosthesis implantation.

    Science.gov (United States)

    Wenger, Markus; Markwalder, Thomas-Marc

    2016-04-01

    This case report presents a 37-year-old man with clinical signs of myelopathy almost 9 years after implantation of a Bryan disc prosthesis (Medtronic Sofamor Danek, Memphis, TN, USA) for C5/C6 soft disc herniation. As demonstrated on MRI and CT scan, spinal cord compression was caused by bony spurs due to heterotopic ossification posterior to the still moving prosthesis. The device, as well as the ectopic bone deposits, had to be removed because of myelopathy and its imminent aggravation. Conversion to anterior spondylodesis was performed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Short-Term Effect of Prosthesis Transforming Sensory Modalities on Walking in Stroke Patients with Hemiparesis

    Science.gov (United States)

    Sekiguchi, Yusuke; Honda, Keita; Ishiguro, Akio

    2016-01-01

    Sensory impairments caused by neurological or physical disorders hamper kinesthesia, making rehabilitation difficult. In order to overcome this problem, we proposed and developed a novel biofeedback prosthesis called Auditory Foot for transforming sensory modalities, in which the sensor prosthesis transforms plantar sensations to auditory feedback signals. This study investigated the short-term effect of the auditory feedback prosthesis on walking in stroke patients with hemiparesis. To evaluate the effect, we compared four conditions of auditory feedback from plantar sensors at the heel and fifth metatarsal. We found significant differences in the maximum hip extension angle and ankle plantar flexor moment on the affected side during the stance phase, between conditions with and without auditory feedback signals. These results indicate that our sensory prosthesis could enhance walking performance in stroke patients with hemiparesis, resulting in effective short-term rehabilitation. PMID:27547456

  19. A kinematic assessment of knee prosthesis from fluoroscopy images

    International Nuclear Information System (INIS)

    Hossain, Mohammad Abrar; Fukunaga, Michihiko; Hirokawa, Shunji

    2008-01-01

    We have developed a technique for estimation 3D motion of knee prosthesis from its 2D perspective projections. Our estimation algorithm includes some innovations such as a two-step estimation algorithm, incorporative use of a geometric articulation model and a new method to solve two silhouettes' overlapping problem. Computer model simulations and experiments results demonstrated that our algorithms give sufficient accuracy. Next, with the cooperation of medical surgeons, we assessed the algorithm's clinical performance by applying it to moving fluoroscopy images of patients who had just undergone total knee arthroplasty (TKA) recently. Our experiments were done in four steps; first we have taken the moving X-ray pictures called fluoroscopy images of the knee prosthesis at different knee motions; second, introduced the absolute positions/orientations for both components, third, introduced the relative positions/orientations between the femoral and the tibial components and finally, introduced the contact points trajectories between the femur and the tibial insert. We drew the estimation results graphically and made the computer-aided detection (CAD) model pictures of the prosthesis, thereby helping us to assess how the relative motions between the femoral and the tibial components were generated. Estimation results of the clinical applications demonstrated that our algorithm worked well as like as theoretical. (author)

  20. Design of equipment safety & reliability for an aseptic liquid food packaging line through maintenance engineering

    OpenAIRE

    Riccetti, Sauro

    2011-01-01

    This thesis was submitted for the degree of Doctor of Philosophy and awarded by Brunel University. The organisation of maintenance, in the Aseptic Liquid Food (ALF) industry, represents an important management task that enables a company to pursue higher manufacturing effectiveness and improved market share. This research is concerned with the process to design and implement maintenance tasks. These two complementary processes (design and implementation) have been thought and designed to a...

  1. A new prosthetic alignment device to read and record prosthesis alignment data.

    Science.gov (United States)

    Pirouzi, Gholamhossein; Abu Osman, Noor Azuan; Ali, Sadeeq; Davoodi Makinejad, Majid

    2017-12-01

    Prosthetic alignment is an essential process to rehabilitate patients with amputations. This study presents, for the first time, an invented device to read and record prosthesis alignment data. The digital device consists of seven main parts: the trigger, internal shaft, shell, sensor adjustment button, digital display, sliding shell, and tip. The alignment data were read and recorded by the user or a computer to replicate prosthesis adjustment for future use or examine the sequence of changes in alignment and its effect on the posture of the patient. Alignment data were recorded at the anterior/posterior and medial/lateral positions for five patients. Results show the high level of confidence to record alignment data and replicate adjustments. Therefore, the device helps patients readjust their prosthesis by themselves, or prosthetists to perform adjustment for patients and analyze the effects of malalignment.

  2. Endoscopic palliation of esophageal and cardial cancer: Nd:YAG laser and prosthesis

    Science.gov (United States)

    Norberto, Lorenzo; Ranzato, Riccardo; Marino, Saverio; Angriman, Imerio; Vella, Vincenzo; Donadi, Michele; D'Amico, D. F.

    1997-12-01

    From November 1, 1992 to January 31, 1997, 227 patients with inoperable esophageal and cardial carcinomas were treated with Nd:YAG laser therapy and prosthesis intubation. The retrograde technique was used in most cases. The tumor involved in 75 pts the Cardia, in 65 the middle thoracic esophagus, in 47 pts the lower thoracic esophagus, in 23 in the upper thoracic esophagus and in 17 in the cervical esophagus. The indications for palliative Nd:YAG laser and prosthesis intubation were a locally advanced or metastatic tumor in 146 pts (64.4%) and poor surgical risk in 81 pts (35.6%). The quality of palliation was evaluated according to the ability to swallow. The mean survival rate of the patients during the follow up was 22 weeks for the laser therapy and 16 weeks for the prosthesis intubation.

  3. The influence of prosthesis diameter in stapes surgery: a meta-analysis and systematic review of the literature.

    Science.gov (United States)

    Laske, Roman D; Röösli, Christof; Chatzimichalis, Michail Vasileios; Sim, Jae Hoon; Huber, Alexander M

    2011-06-01

    To analyze the influence of stapes prosthesis diameter on postoperative hearing results after stapedotomy without interposition in otosclerotic patients. PubMed search from 1970 to 2009 using the key words stapedotomy or stapedectomy or otosclerosis or stapesplasty. Inclusion criteria to select articles and patient groups for meta-analysis and statistical analyses were as follows: otosclerosis as diagnosis, clear description of technique and prosthesis size, calibrated stapedotomy, and complete report of functional results. Five controlled studies were found analyzing the influence of prosthesis diameter and reporting the results in a comparable way for meta-analysis (n = 590). Sixty-two studies not analyzing the influence of prosthesis diameter contained comparable subgroups with a total of 9,536 cases. These cases were pooled according to their diameter (0.3, 0.4, 0.5, 0.6,and 0.8 mm). The results of air conduction, bone conduction, air-bone gap (ABG), and success rate (closure of the ABG within 10 dB as percentage of the total cases) for all groups and frequency-specific ABG results were gathered. Furthermore, 12 clinical and experimental studies were reviewed that did not contribute to the statistical analysis. A meta-analysis performed for success rate of the 5 controlled studies showed favorable results for 0.6-mm over 0.4-mm prostheses (success rate, 67% versus 58%, p = 0.05). In the statistical analysis of the pooled data, the 0.6-mm prosthesis showed better results compared with 0.4 mm (p prosthesis in the high frequencies. There was no difference in postoperative change of bone conduction in the 0.6- and 0.4-mm groups. Statistically significant results could not be assessed for other prosthesis diameters because of the small number of cases reported. A 0.6-mm diameter piston prosthesis is associated with significantly better results than a 0.4-mm prosthesis and should be used if the surgical conditions allow it.

  4. Phantom studies of triple photon absorptiometry and bone mineral measurement at a hip prosthesis

    International Nuclear Information System (INIS)

    Farrell, T.J.; Webber, C.E.

    1992-01-01

    The feasibility of using triple photon absorptiometry (TPA) for the measurement of bone mineral mass about a hip prosthesis was examined. A theoretical expression describing the variance of TPA measurements was verified using a triple photon source and phantom materials which simulate the soft tissue-bone mineral-metal prosthesis system. The expression for the variance was used to determine an optimized set of photon energies. It was shown that a precision of 3% could be obtained for reasonable measurement times using this optimized set of energies and that TPA should be a feasible approach for measurement of bone mineral about a hip prosthesis. (orig.)

  5. [Microbiological characteristics and patterns of resistance in prosthetic joint infections in a referral hospital].

    Science.gov (United States)

    Ortega-Peña, Silvestre; Colín-Castro, Claudia; Hernández-Duran, Melissa; López-Jácome, Esaú; Franco-Cendejas, Rafael

    2015-01-01

    The prosthetic joint infection is the most feared and catastrophic complication for cause severe physical damage to patients and, generates high economic costs. To describe the microbiological characteristics and to determine the resistance pattern in prosthetic joint infections in a reference hospital in Mexico. Patients whose prosthetic devices were withdrawn due to suspicion of septic and aseptic loosening were included. Cultures were performed to identify microorganisms and susceptibility analysis. Of the 111 patients included, 55% were diagnosed with prosthetic joint infection, with the most frequent prosthesis being of the hip (43%). Positive cultures were obtained in 97% of the infected cases, of which 75% were monomicrobial infections. The most frequent bacterial species isolated were: Staphylococcus epidermidis (31%), Enterococcus faecalis (16%), Staphylococcus aureus (13%), and Escherichia coli (8%). The resistance patterns for the Staphylococcus genus were: oxacillin (79%), erythromycin (45%) and ciprofloxacin (37%). Enterococcus faecalis showed a high percentage of resistance to erythromycin and clindamycin (86%), and fluoroquinolones (43%). The large majority (86%) of Escherichia coli were extended spectrum beta-lactamases positive, in addition to having high resistance to fluoroquinolones (86%), trimethoprim/sulfamethoxazole (86%) and gentamicin (72%). The microbiological characteristics found in prosthetic joint infections vary according to the hospitals. In this series, a high proportion of coagulase-negative Staphylococci and Enterococcus spp. were found, as well as a high bacterial resistance. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  6. 21 CFR 888.3360 - Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) metallic cemented or... Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis is a device intended to be implanted...

  7. [COMPUTER ASSISTED DESIGN AND ELECTRON BEAMMELTING RAPID PROTOTYPING METAL THREE-DIMENSIONAL PRINTING TECHNOLOGY FOR PREPARATION OF INDIVIDUALIZED FEMORAL PROSTHESIS].

    Science.gov (United States)

    Liu, Hongwei; Weng, Yiping; Zhang, Yunkun; Xu, Nanwei; Tong, Jing; Wang, Caimei

    2015-09-01

    To study the feasibility of preparation of the individualized femoral prosthesis through computer assisted design and electron beammelting rapid prototyping (EBM-RP) metal three-dimensional (3D) printing technology. One adult male left femur specimen was used for scanning with 64-slice spiral CT; tomographic image data were imported into Mimics15.0 software to reconstruct femoral 3D model, then the 3D model of individualized femoral prosthesis was designed through UG8.0 software. Finally the 3D model data were imported into EBM-RP metal 3D printer to print the individualized sleeve. According to the 3D model of individualized prosthesis, customized sleeve was successfully prepared through the EBM-RP metal 3D printing technology, assembled with the standard handle component of SR modular femoral prosthesis to make the individualized femoral prosthesis. Customized femoral prosthesis accurately matching with metaphyseal cavity can be designed through the thin slice CT scanning and computer assisted design technology. Titanium alloy personalized prosthesis with complex 3D shape, pore surface, and good matching with metaphyseal cavity can be manufactured by the technology of EBM-RP metal 3D printing, and the technology has convenient, rapid, and accurate advantages.

  8. Novel use of an air-filled breast prosthesis to allow radiotherapy to recurrent colonic cancer.

    LENUS (Irish Health Repository)

    O'Duffy, F

    2012-02-01

    AiM: The authors present the novel and successful use of an air-filled breast prosthesis for extra pelvic exclusion of small bowel to facilitate adjuvant radiotherapy following resection of recurrent adenocarcinoma of the ascending bowel. The therapeutic use of radiotherapy in colon cancer can cause acute or chronic radiation enteropathy. Mobile small bowel can be sequestered in \\'dead space\\' or by adhesions exposing it to adjuvant radiotherapy. A variety of pelvic partitioning methods have been described to exclude bowel from radiation fields using both native and prosthetic materials. METHOD: In this case a 68 year old presented with ascending colon adenocarcinoma invading the peritoneum and underwent en bloc peritoneal resection. Thirty-seven months later surveillance CT identified a local recurrence. Subsequent resection resulted in a large iliacus muscle defect which would sequester small bowel loops thus exposing the patient to radiation enteropathy. The lateral position of the defect precluded the use of traditional pelvic partitioning methods which would be unlikely to remain in place long enough to allow radiotherapy. A lightweight air-filled breast prosthesis (Allergan 133 FV 750 cms) secured in place with an omentoplasty was used to fill the defect. RESULTS: Following well tolerated radiotherapy the prosthesis was deflated under ultrasound guidance and removed via a 7-cm transverse incision above the right iliac crest. The patient is disease free 18 months later with no evidence of treatment related morbidity. CONCLUSION: The use of a malleable air-filled prosthesis for pelvic partitioning allows specific tailoring of the prosthesis size and shape for individual patient defects. It is also lightweight enough to be secured in place using an omentoplasty to prevent movement related prosthesis migration. In the absence of adequate omentum a mesh sling may be considered to allow fixation. In this case the anatomy of the prosthesis position allowed for its

  9. Towards a Completely Implantable, Light-Sensitive Intraocular Retinal Prosthesis

    National Research Council Canada - National Science Library

    Humayun, M

    2001-01-01

    An electronic retinal prosthesis is under development to treat retinitis pigmentosa and age-related macular degeneration, two presently incurable diseases of the outer retina that afflict millions world-wide...

  10. Cloning higher plants from aseptically cultured tissues and cells

    Science.gov (United States)

    Krikorian, A. D.

    1982-01-01

    A review of aseptic culture methods for higher plants is presented, which focuses on the existing problems that limit or prevent the full realization of cloning plants from free cells. It is shown that substantial progress in clonal multiplication has been made with explanted stem tips or lateral buds which can be stimulated to produce numerous precocious axillary branches. These branches can then be separated or subdivided and induced to root in order to yield populations of genetically and phenotypically uniorm plantlets. Similarly, undifferentiated calluses can sometimes be induced to form shoots and/or roots adventitiously. Although the cell culture techniques required to produce somatic embryos are presently rudimentary, steady advances are being made in learning how to stimulate formation of somatic or adventive embryos from totipotent cells grown in suspension cultures. It is concluded that many problems exist in the producing and growing of totipotent or morphogenetically competent cell suspensions, but the potential benefits are great.

  11. Biomedical and psychosocial factors influencing transtibial prosthesis fit : a Delphi survey among health care professionals

    NARCIS (Netherlands)

    Baars, Erwin C.; Schrier, Ernst; Geertzen, Jan H.; Dijkstra, Pieter U.

    2015-01-01

    Purpose: We aimed to reach consensus among professionals caring for prosthesis users, on definitions of biomedical and psychosocial factors, to assess their influence on fit of transtibial prosthesis and to identify new factors. Method: A three-round, internet-based, Delphi survey was conducted

  12. An innovative and simple approach to fabricate a hollow ocular prosthesis with functional lubricant reservoir: A solution to artificial eye comfort

    Directory of Open Access Journals (Sweden)

    Aditya Anil Kavlekar

    2017-01-01

    Full Text Available The loss of an eye is an emotional and psychological setback to the patient. An ocular prosthesis is created to restore the lost anatomical structure and to correct the cosmetic defect. The tear reflexes do not function at optimal levels in anophthalmic sockets which make prosthesis wear uncomfortable. This case report presents an innovative hollow ocular prosthesis with functional lubricant reservoir which upon normal blinking would draw the lubricant from the reservoir through an exit hole which spreads over the prosthesis allowing a comfortable and long duration of prosthesis wear.

  13. Reamed intramedullary exchange nailing in the operative treatment of aseptic tibial shaft nonunion.

    Science.gov (United States)

    Hierholzer, Christian; Friederichs, Jan; Glowalla, Claudio; Woltmann, Alexander; Bühren, Volker; von Rüden, Christian

    2017-08-01

    The aim of this study was to evaluate a standardized treatment protocol regarding the rate of secondary bone union, complications, and functional outcome. This study was started as a prospective study in a single Level I Trauma Centre between 2003 and 2012. The study group consisted of 188 patients with the diagnosis of an aseptic tibial shaft nonunion. Exchange nailing was performed following a standardized surgical protocol. Long-term follow-up was analyzed for rate of bone healing and functional outcome. Osseous healing was achieved in 182 out of 188 patients (97 %). In 165 out of 188 patients (88 %), bone healing was observed timely and uneventfully after a single exchange nailing procedure. An open approach was necessary in 32 patients (17 %). Twenty-three patients (12 %) required additional therapy such as extracorporeal shock wave therapy. Post-operative complications were observed in seven patients (4 %). Almost all patients demonstrated osseous healing within 12 months, with the majority of osseous healing occurring within six months. A relevant shortening of the fractured tibia was observed in 20 out of 188 patients (11 %). After a median follow-up of 23 months (range 12-45 months), outcome was evaluated using the assessment system of Friedman/Wyman. In summary, 154 out of 188 patients (82 %) had a good functional long-term result. Reamed intramedullary exchange nailing including correction of axis alignment is a safe and effective treatment of aseptic tibial shaft nonunion with a high rate of bone healing and a good radiological and functional long-term outcome.

  14. Ipsilateral Fracture Shaft Femur with Neglected Dislocation of Prosthesis: A Case Report

    Directory of Open Access Journals (Sweden)

    Mantu Jain

    2013-10-01

    Full Text Available Introduction: Neglected hip dislocation is rare in today’s world and after prosthesis replacement even rarer finding. However such patients may not report to surgeons until they develop secondary complications. Management of such patient’s is a challenge to the treating surgeon and need to be tailored suiting to patient’s demands, expectations and constraints of financial resources. We did not find a similar case in the electronic and print media and therefore report this case which was innovatively managed. Case Report: A 60 year farmer presented with fracture shaft femur and ipsilateral dislocation prosthesis of right hip. He had a hemiarthroplasty done for fracture neck of femur in the past but used to walk with a lurch since he started to ambulate after discharge. However he was satisfied despite “some problems” which had caused shortening of his limb. The patient was informed of the various treatment options and their possible complications. He expressed his inability to afford a Total Hip Arthroplasty (THA at any stage and consented for other options discussed with him. The patient was positioned supine and adductor tenotomy done. Next he was positioned laterally and the fracture was fixed with heavy duty broad dynamic compression plate and screws. The wound was temporarily closed. Now through the previous scar via posterior approach the hip was exposed. The prosthesis was found to be firmly fixed to the proximal femur. The acetabulum was cleared with fibrous tissue. All attempts the prosthesis to relocate the prosthesis failed after several attempts and it was best decided to leave alone. Post operatively period was uneventful. At follow up he refused for any further manoeuvre in future inform of heavy traction and attempts to reduce the same. At one year when he was walking unaided and his X-rays showed that fracture had well united his SF-36 score was PCS – 49.6 and MCS – 51.9. Conclusion: Ipsilateral shaft femur fracture

  15. Endotoxin as a cause of aseptic meningitis after radionuclide cisternography

    International Nuclear Information System (INIS)

    Cooper, J.F.; Harbert, J.C.

    1975-01-01

    The role of pyrogens in aseptic meningitis after radionuclide cisternography was studied by means of the Limulus test, a sensitive detector of endotoxin. During a 15-month period, 39 reactions associated with cisternography were reported. Ten samples of specific lots of the radioactive drugs implicated in 20 of these reactions were tested and all reacted strongly positive to the Limulus test. The less sensitive rabbit pyrogen test was negative for these preparations when tested on a dose-per-weight basis. Our findings apparently provide clinical evidence for the observation made in animals that endotoxin is at least 1,000 times more toxic intrathecally than intravenously. The data implicate endotoxin contamination as a cause of adverse reactions to radionuclide cisternography. We conclude that the USP pyrogen test is insufficiently sensitive for intrathecal injectables and should be supplemented by the Limulus test. (auth)

  16. Bicentric bipolar hip prosthesis: A radiological study of movement at the interprosthetic joint

    Directory of Open Access Journals (Sweden)

    Anil Kumar Rai

    2011-01-01

    Full Text Available Background: The bipolar hip prostheses after some time functions as a unipolar device. There is a need to change the design of bipolar hip prostheses to make it function as a bipolar device over a prolonged period of time. A bicentric bipolar hip prosthesis was used as an implant for various conditions of the hip. We evaluated the movement of this newly developed prosthesis at the interprosthetic joint radiologically at periodic intervals. Materials and Methods: Fifty two cases were operarted with the Bicentric bipolar prosthesis for indications like fracture neck of femur and various other diseases of the hip and were followed up with serial radiographs at periodic intervals to evaluate, what fraction of the total abduction at the hip was occurring at the interprosthetic joint. Results: In cases of intracapsular fracture neck of femur, the percentage of total abduction occurring at the interprosthetic joint at 3 months follow-up was 33.74% (mean value of all the patients, which fell to 25.66% at 1.5 years. In indications for bipolar hemireplacement other than fracture neck of femur, the percentage of total abduction occurring at the interprosthetic joint at 3 months follow-up was 71.71% (mean value and at 1.5 years it was 67.52%. Conclusion: This study shows the relative preservation of inner bearing movement in the bipolar hip prosthesis with time probably due its refined design. Further refinements are needed to make the prosthesis work better in patients of intracapsular fracture neck femur.

  17. Evidence of echoic memory with a multichannel cochlear prosthesis.

    Science.gov (United States)

    Jerger, S; Watkins, M J

    1988-10-01

    Short-term memory was examined in a subject with a multichannel cochlear prosthesis. Serial recall for lists of digits revealed what are widely regarded as the principal hallmarks of echoic memory, namely the recency effect and the suffix effect. Thus, probability of recall increased for the last one or two digits, except when a nominally irrelevant but spoken item was appended to the to-be-remembered list. It appears, therefore, that a multichannel cochlear implant can give rise to not only the perception of, but also an echoic memory for, speech. As with normal subjects, the suffix effect did not occur with a nonspeech suffix, implying that the echoic memory from the prosthesis shows normal sensitivity to the distinction between speech and nonspeech.

  18. Aortic valve prosthesis-patient mismatch and exercise capacity in adult patients with congenital heart disease

    NARCIS (Netherlands)

    van Slooten, Ymkje J.; Melle, van Joost P.; Freling, Hendrik G.; Bouma, Berto J.; van Dijk, Arie P. J.; Jongbloed, Monique R. M.; Post, Martijn C.; Sieswerda, Gertjan T.; in 't Veld, Anna Huis; Ebels, Tjark; Voors, Adriaan A.; Pieper, Petronella G.

    Objectives To report the prevalence of aortic valve prosthesis patient mismatch (PPM) in an adult population with congenital heart disease (CHD) and its impact on exercise capacity. Adults with congenital heart disease (ACHD) with a history of aortic valve replacement may outgrow their prosthesis

  19. Aortic valve prosthesis-patient mismatch and exercise capacity in adult patients with congenital heart disease

    NARCIS (Netherlands)

    van Slooten, Ymkje J.; van Melle, Joost P.; Freling, Hendrik G.; Bouma, Berto J.; van Dijk, Arie Pj; Jongbloed, Monique Rm; Post, Martijn C.; Sieswerda, Gertjan T.; Huis In 't Veld, Anna; Ebels, Tjark; Voors, Adriaan A.; Pieper, Petronella G.

    2016-01-01

    To report the prevalence of aortic valve prosthesis-patient mismatch (PPM) in an adult population with congenital heart disease (CHD) and its impact on exercise capacity. Adults with congenital heart disease (ACHD) with a history of aortic valve replacement may outgrow their prosthesis later in

  20. Prosthetic replacement of the medial meniscus in cadaveric knees - Does the prosthesis mimic the functional behavior of the native meniscus?

    NARCIS (Netherlands)

    Tienen, TG; Verdonschot, N; Heijkants, RGJC; Buma, R; Scholten, JGF; van Kampen, A; Veth, RPH

    2004-01-01

    Meniscus replacement by a polymer meniscus prosthesis in dogs resulted in generation of new meniscal tissue. Hypothesis: Optimal functioning of the prosthesis would involve realistic deformation and motion patterns of the prosthesis during knee joint motion. Study Design: Controlled laboratory

  1. The Talar Body Prosthesis: Results at Ten to Thirty-six Years of Follow-up.

    Science.gov (United States)

    Harnroongroj, Thos; Harnroongroj, Thossart

    2014-07-16

    Satisfactory results of implantation of the talar body prosthesis were reported in 1997, although some complications associated with the initial design were noted. The present study evaluated outcomes of treatment with a modified talar body prosthesis. Of the thirty-six talar body prostheses implanted with use of a transmalleolar surgical approach from 1974 to 2011, thirty-three were available for follow-up at ten to thirty-six years or had failed prior to that time. The indication for implantation had been osteonecrosis in twenty-three patients, a comminuted talar fracture in eight, and a talar body tumor in two. Twenty-eight of the thirty-three prostheses were still in place at the time of final follow-up and five had failed prior to five years. The duration of follow-up was ten to twenty years in eight patients, twenty to thirty years in eleven, and thirty to thirty-six years in nine. The AOFAS (American Orthopaedic Foot & Ankle Society) ankle-hindfoot score did not differ significantly among these three groups. Patients over sixty-five years of age with underlying disease that impeded walking ability had lower AOFAS scores. Early prosthesis failure occurred as a result of size mismatch in two patients, tumor recurrence in one, infection in one, and osteonecrosis of the talar head and neck in one. These failures, which occurred at eight to fifty-seven months, were treated with tibiotalar arthrodesis in three patients, prosthesis revision in one, and below-the-knee amputation in one. Although early prosthesis failure may occur, survival of the talar body prosthesis can provide satisfactory ankle and foot function. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  2. Investigation of the in-vitro loading on an artificial spinal disk prosthesis

    Energy Technology Data Exchange (ETDEWEB)

    Kyriacou, P A; Pancholi, M P [School of Engineering and Mathematical Sciences, City University London (United Kingdom); Yeh, J, E-mail: P.Kyriacou@city.ac.u [Department of Neurosurgery, Royal London Hospital, Barts and the London NHS Trust, London (United Kingdom)

    2009-07-01

    Spinal diseases imposes considerable burden to both patients and society. In recent years, much surgical efforts have been made in advancing the treatment of neck and back pain. Of particular prominence is the increasing clinical acceptance and use of intervertebral artificial disk prosthesis for the treatment of discogenic back pain. Despite this increased use of such disks, their in-vivo monitoring remains rudimentary. In an effort to develop an intelligent artificial spinal disk where the in-vivo loading of the spine can by studied for the first time an experimental set up has been created in order to initially study the in-vitro loading on an artificial disc prosthesis. Eight strain gauges and two piezoresistive sensors were used and placed suitably in the artificial disk prosthesis. The results from the in-vitro loading showed linear relationship between loading and the outputs from the sensors with good repeatability and less hysteresis.

  3. Investigation of the in-vitro loading on an artificial spinal disk prosthesis

    International Nuclear Information System (INIS)

    Kyriacou, P A; Pancholi, M P; Yeh, J

    2009-01-01

    Spinal diseases imposes considerable burden to both patients and society. In recent years, much surgical efforts have been made in advancing the treatment of neck and back pain. Of particular prominence is the increasing clinical acceptance and use of intervertebral artificial disk prosthesis for the treatment of discogenic back pain. Despite this increased use of such disks, their in-vivo monitoring remains rudimentary. In an effort to develop an intelligent artificial spinal disk where the in-vivo loading of the spine can by studied for the first time an experimental set up has been created in order to initially study the in-vitro loading on an artificial disc prosthesis. Eight strain gauges and two piezoresistive sensors were used and placed suitably in the artificial disk prosthesis. The results from the in-vitro loading showed linear relationship between loading and the outputs from the sensors with good repeatability and less hysteresis.

  4. Total knee arthroplasty

    DEFF Research Database (Denmark)

    Schrøder, Henrik M.; Petersen, Michael M.

    2016-01-01

    Total knee arthroplasty (TKA) is a successful treatment of the osteoarthritic knee, which has increased dramatically over the last 30 years. The indication is a painful osteoarthritic knee with relevant radiographic findings and failure of conservative measures like painkillers and exercise...... surgeon seems to positively influence the rate of surgical complications and implant survival. The painful TKA knee should be thoroughly evaluated, but not revised except if a relevant indication can be established. The most frequent indications for revision are: aseptic loosening, instability, infection...

  5. Design and Control of a New Biomimetic Transfemoral Knee Prosthesis Using an Echo-Control Scheme

    Directory of Open Access Journals (Sweden)

    Mario G. Bernal-Torres

    2018-01-01

    Full Text Available Passive knee prostheses require a significant amount of additional metabolic energy to carry out a gait cycle, therefore affecting the natural human walk performance. Current active knee prostheses are still limited because they do not reply with accuracy of the natural human knee movement, and the time response is relatively large. This paper presents the design and control of a new biomimetic-controlled transfemoral knee prosthesis based on a polycentric-type mechanism. The aim was to develop a knee prosthesis able to provide additional power and to mimic with accuracy of the natural human knee movement using a stable control strategy. The design of the knee mechanism was obtained from the body-guidance kinematics synthesis based on real human walking patterns obtained from computer vision and 3D reconstruction. A biomechanical evaluation of the synthesized prosthesis was then carried out. For the activation and control of the prosthesis, an echo-control strategy was proposed and developed. In this echo-control strategy, the sound side leg is sensed and synchronized with the activation of the knee prosthesis. An experimental prototype was built and evaluated in a test rig. The results revealed that the prosthetic knee is able to mimic the biomechanics of the human knee.

  6. New protocol for construction of eyeglasses-supported provisional nasal prosthesis using CAD/CAM techniques.

    Science.gov (United States)

    Ciocca, Leonardo; Fantini, Massimiliano; De Crescenzio, Francesca; Persiani, Franco; Scotti, Roberto

    2010-01-01

    A new protocol for making an immediate provisional eyeglasses-supported nasal prosthesis is presented that uses laser scanning, computer-aided design/computer-aided manufacturing procedures, and rapid prototyping techniques, reducing time and costs while increasing the quality of the final product. With this protocol, the eyeglasses were digitized, and the relative position of the nasal prosthesis was planned and evaluated in a virtual environment without any try-in appointment. This innovative method saves time, reduces costs, and restores the patient's aesthetic appearance after a disfiguration caused by ablation of the nasal pyramid better than conventional restoration methods. Moreover, the digital model of the designed nasal epithesis can be used to develop a definitive prosthesis anchored to osseointegrated craniofacial implants.

  7. Perivalvular pannus and valve thrombosis: two concurrent mechanisms of mechanical valve prosthesis dysfunction.

    Science.gov (United States)

    Arnáiz-García, María Elena; González-Santos, Jose María; Bueno-Codoñer, María E; López-Rodríguez, Javier; Dalmau-Sorlí, María José; Arévalo-Abascal, Adolfo; Arribas-Jiménez, Antonio; Diego-Nieto, Alejandro; Rodríguez-Collado, Javier; Rodríguez-López, Jose María

    2015-02-01

    A 78-year-old woman was admitted to our institution with progressive dyspnea. She had previously been diagnosed with rheumatic heart disease and had undergone cardiac surgery for mechanical mitral valve replacement ten years previously. Transesophageal echocardiography revealed blockage of the mechanical prosthesis and the patient was scheduled for surgery, in which a thrombus was removed from the left atrial appendage. A partial thrombosis of the mechanical prosthesis and circumferential pannus overgrowth were concomitantly detected. Prosthetic heart valve blockage is a rare but life-threatening complication, the main causes of which are thrombosis and pannus formation. The two conditions are different but both are usually misdiagnosed. Two concurrent mechanisms of prosthesis blockage were found in this patient. Copyright © 2014 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  8. Sexual Function and Quality of Life Before and After Penile Prosthesis Implantation Following Radial Forearm Flap Phalloplasty.

    Science.gov (United States)

    Young, Ezekiel E; Friedlander, Daniel; Lue, Kathy; Anele, Uzoma A; Khurgin, Jacob L; Bivalacqua, Trinity J; Burnett, Arthur L; Redett, Richard J; Gearhart, John P

    2017-06-01

    To provide sexual function and quality of life outcomes in patients with severe penile deficiency who underwent radial forearm flap phalloplasty with and without penile prosthesis implantation. Patients with history of severe penile deficiency who underwent microsurgical radial forearm flap phalloplasty with and without penile prosthesis implantation between 2007 and 2014 were identified. They completed a set of web-based validated questionnaires including the International Index of Erectile Function, the Pediatric Penile Perception Score, the Sexual Quality of Life for Men, and several items addressing general quality of life. Outcomes were compared between groups. Nine of the 12 identified patients who had prosthesis after phalloplasty and 4 out of the 7 phalloplasty-only patients completed the survey, resulting in an overall response rate of 68%. Among the phalloplasty-prosthesis patients, 66% reported current sexual activity and 78% reported regular masturbation, whereas 1 of the 4 phalloplasty-only patients reported both. Prosthesis patients scored notably higher in all domains of the International Index of Erectile Function except for sexual desire. In contrast, they demonstrated similar scores of penile perception, as well as general and sexual quality of life. Among patients who have undergone flap phalloplasty, the subsequent placement of penile prosthesis appears to effectively allow for both intercourse and masturbation, resulting in measurable improvements in orgasmic function, intercourse satisfaction, and overall sexual satisfaction. Despite these important benefits, prosthesis placement does not appear to result in improvements in penile perception scores, or general or sexual quality of life. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Complications and Clinical Considerations of the Implant-Retained Zirconia Complete-Arch Prosthesis with Various Opposing Dentitions.

    Science.gov (United States)

    Gonzalez, Jorge; Triplett, Robert G

    To evaluate the performance of the implant-retained zirconia complete-arch prosthesis with various opposing dentitions. The 40 patients included in this retrospective case series study were treated with one or two implant-retained zirconia complete-arch prostheses (ZIRCAP) using the Zirkonzahn protocol. Prettau zirconia frames were created with strategic cutbacks in the structure to extend zirconia incisal coverage of the esthetic anterior sextants and complete monolithic zirconia in the molar areas; subsequent layers of porcelain were applied to nonfunctional and esthetic areas. Patients had three possible occlusal scenarios: (1) maxillary ZIRCAP and mandibular ZIRCAP, (2) maxillary ZIRCAP and mandibular natural dentition, and (3) maxillary ZIRCAP and mandibular conventional hybrid prosthesis. Complications were recorded during follow-up appointments 3, 6, and 12 months after definitive prosthesis delivery. The mean treatment observation period was 33 months. Eight prosthetic complications were noted for the 40 implant-retained zirconia complete-arch prostheses (18.18%), including six cases of minor porcelain chipping and two cases of debonding of the metal insert from the zirconia framework. Maxillary ZIRCAP opposing mandibular ZIRCAP and maxillary ZIRCAP opposing mandibular natural dentition occlusal scenarios presented the same complication ratio of 4. No complications were seen in the maxillary ZIRCAP opposing mandibular conventional hybrid prosthesis group, yet 16 complications were found as denture tooth fractures in 12 mandibular conventional hybrid prostheses (ratio of 0.75). The results indicate that the implant-retained zirconia complete-arch prosthesis offers acceptable performance for use as an alternative to the conventional titanium framework acrylic veneer prosthesis for complete edentulism with a lower incidence of prosthetic complications and fewer maintenance appointments. Chipping of veneering porcelain was the most common complication, but a

  10. Prosthesis-patient mismatch

    Directory of Open Access Journals (Sweden)

    Philippe Pibarot

    2011-04-01

    Full Text Available Prosthesis-patient mismatch (PPM is present when the effective orifice area of the inserted prosthetic valve is too small in relation to body size. Its main hemodynamic consequence is to generate higher than expected gradients through normally functioning prosthetic valves. The purpose of this review is to present an update on the present state of knowledge with regards to diagnosis, prognosis and prevention of PPM. PPM is a frequent occurrence (20%–70% of aortic valve replacements that has been shown to be associated with worse hemodynamics, less regression of left ventricular hypertrophy, more cardiac events, and lower survival. Moreover, as opposed to most other risk factors, PPM can largely be prevented by using a prospective strategy at the time of operation.

  11. Bioelectronic retinal prosthesis

    Science.gov (United States)

    Weiland, James D.

    2016-05-01

    Retinal prosthesis have been translated to clinical use over the past two decades. Currently, two devices have regulatory approval for the treatment of retinitis pigmentosa and one device is in clinical trials for treatment of age-related macular degeneration. These devices provide partial sight restoration and patients use this improved vision in their everyday lives to navigate and to detect large objects. However, significant vision restoration will require both better technology and improved understanding of the interaction between electrical stimulation and the retina. In particular, current retinal prostheses do not provide peripheral visions due to technical and surgical limitations, thus limiting the effectiveness of the treatment. This paper reviews recent results from human implant patients and presents technical approaches for peripheral vision.

  12. In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening

    Science.gov (United States)

    Demircan, Sabit; Cene, Erhan; Aya, Serhan Aydın; Erdem, Mehmet Ali; Cankaya, Abdulkadir Burak

    2017-01-01

    Preload is applied to screws manually or using a torque wrench in dental implant systems, and the preload applied must be appropriate for the purpose. The aim of this study was to assess screw loosening and bending/torsional moments applied by clinicians of various specialties following application of manual tightening torque to combinations of implants and abutments. Ten-millimeter implants of 3.7 and 4.1 mm diameters and standard or solid abutments were used. Each group contained five implant-abutment combinations. The control and experimental groups comprised 20 and 160 specimens, respectively. Implants in the experimental group were tightened by dentists of different specialties. Torsional and bending moments during tightening were measured using a strain gauge. Control group and implants with preload values close to the ideal preload were subjected to a dynamic loading test at 150 N, 15 Hz, and 85,000 cycles. The implants that deformed in this test were examined using an optical microscope to assess deformities. Manual tightening did not yield the manufacturer-recommended preload values. Dynamic loading testing suggested early screw loosening/fracture in samples with insufficient preload. PMID:28473988

  13. [Poldi-Čech cemented femoral stem in total hip arthroplasty after 25 years].

    Science.gov (United States)

    Rozkydal, Z; Janíček, P

    2010-08-01

    The aim of the study was to evaluate the results of Poldi-Čech femoral stem implantation in primary total hip arthroplasty after 25 years. A group of 65 patients (90 hips) with Poldi-Čech total hip arthroplasty carried out between 1974 and 1984 was evaluated at the end of 2009. The mean follow-up of all patients was 28 years (25 to 35). There were seven men and 58 women. The mean age at the time of implantation was 43 years (26 to 60) and at the latest follow-up it was 72 years. In all patients the cemented UHMW PE acetabular component (RCH 1000) was used together with AKV Ultra 2 Poldi steel femoral stems (1st, 2nd and 3rd generations). The stem was a monoblock with a 32-mm head. The evaluation of the results was based on the Harris hip score and X ray with an A-P view of the pelvis and the affected hip. Statistical analysis was made using the life-table method. At the latest follow up the mean Harris score was 69.7 points (40 to 88). There were 69 hips with an original Poldi-Čech femoral component still in situ, 64 of them were stable and five with radiological evidence of aseptic loosening. Five patients had undergone Girdlestone resection arthroplasty for septic loosening. Thirteen patients (16 hips) had femoral stem revision. The cumulative proportion of clinical survivorship of the Poldi-Čech femoral stem, with revision for any reason as the endpoint, .was 0.93 at 6 years, 0.84 at 12 years, and 0.77 at 18, 24 and 30 years after the index surgery. Radiographic findings revealed 64 hips with stable stems, five hips with ;aseptic loosening (probable, 0 possible, 2, definite, 3). Six- teen hips were after revision surgery for aseptic loosening of the stem and five hips were after Girdlestone resection arthroplasty for septic failure. The cumulative proportion of radiological survivorship of the Poldi-Čech femoral stem with any reason as the endpoint was 0.92 at 6 years, 0.78 at 12 years, 0.72 at 18 years, 0.69 at 24 years and 0.69 at 30 years. The Poldi

  14. Potencial de descompactação de um Argissolo promovido pelo capim-tifton 85 Loosening potential of an Argisol promoted by tifton 85 grass

    Directory of Open Access Journals (Sweden)

    Eduardo C. Severiano

    2010-01-01

    Full Text Available A produção de forragens conservadas utilizando-se um tráfego intenso de maquinário sob condições inadequadas de água no solo, tem condicionado compactação do solo e a degradação das pastagens. No enfrentamento desta grave questão faz-se necessário o conhecimento do potencial de descompactação do solo, promovido por algumas forrageiras. Objetivou-se, com o presente trabalho, avaliar a descompactação de um Argissolo ao ser cultivado com capim-tifton 85 e sua produção. O experimento foi conduzido na Universidade Federal de Lavras, no período de fevereiro a junho de 2007, em delineamento inteiramente casualizado cultivando-se o capim-tifton nos seguintes graus de compactação do solo: 66, 83, 88, 92 e 98%. Avaliaram-se os atributos físicos, o comportamento compressivo do solo e a produção de massa seca do capim. A descompactação foi quantificada pela redução da pressão de preconsolidação após o cultivo. Os modelos de capacidade de suporte de carga refletiram as alterações na macroporosidade do solo. Nas condições do estudo o capim-tifton 85 promoveu a descompactação do solo, a qual é diretamente proporcional ao grau de compactação inicial. A produção de forragem aumenta sempre que o solo é descompactado.The production of conserved forages using an intense traffic of machinery under inadequate conditions of water content in the soil has caused soil compaction and the degradation of pastures. In order to face this serious problem it is necessary to know the potential of soil loosening by some forage plants. The objective of the present study was to evaluate the loosening of an Argisol cultivated with Tifton 85 grass, as well as its production. The experiment was conducted at the Federal University of Lavras, from February to June 2007, using a completely randomized design, cultivating the Tifton 85 grass under the following compaction degrees: 66, 83, 88, 92 and 98%. The physical attributes, the compressive

  15. Numerical analysis of an osseointegrated prosthesis fixation with reduced bone failure risk and periprosthetic bone loss

    NARCIS (Netherlands)

    Tomaszewski, P. M.; van Diest, M.; Bulstra, S. K.; Verdonschot, N.; Verkerke, G. J.

    2012-01-01

    Currently available implants for direct attachment of prosthesis to the skeletal system after transfemoral amputation (OPRA system. Integrum AB, Sweden and ISP Endo/Exo prosthesis, ESKA Implants AG, Germany) show many advantages over the conventional socket fixation. However, restraining

  16. THR Simulator – the software for generating radiographs of THR prosthesis

    Directory of Open Access Journals (Sweden)

    Hou Sheng-Mou

    2009-01-01

    Full Text Available Abstract Background Measuring the orientation of acetabular cup after total hip arthroplasty is important for prognosis. The verification of these measurement methods will be easier and more feasible if we can synthesize prosthesis radiographs in each simulated condition. One reported method used an expensive mechanical device with an indeterminable precision. We thus develop a program, THR Simulator, to directly synthesize digital radiographs of prostheses for further analysis. Under Windows platform and using Borland C++ Builder programming tool, we developed the THR Simulator. We first built a mathematical model of acetabulum and femoral head. The data of the real dimension of prosthesis was adopted to generate the radiograph of hip prosthesis. Then with the ray tracing algorithm, we calculated the thickness each X-ray beam passed, and then transformed to grey scale by mapping function which was derived by fitting the exponential function from the phantom image. Finally we could generate a simulated radiograph for further analysis. Results Using THR Simulator, the users can incorporate many parameters together for radiograph synthesis. These parameters include thickness, film size, tube distance, film distance, anteversion, abduction, upper wear, medial wear, and posterior wear. These parameters are adequate for any radiographic measurement research. This THR Simulator has been used in two studies, and the errors are within 2° for anteversion and 0.2 mm for wearing measurement. Conclusion We design a program, THR Simulator that can synthesize prosthesis radiographs. Such a program can be applied in future studies for further analysis and validation of measurement of various parameters of pelvis after total hip arthroplasty.

  17. Debris from cobalt-chrome cable may cause acetabular loosening.

    Science.gov (United States)

    Kelley, S S; Johnston, R C

    1992-12-01

    To address the issue of nonunion with trochanteric osteotomy, surgeons have experimented with various modes of fixation, wire and cable being the two most popular. From a group of 643 primary cemented total hip arthroplasties performed by a single surgeon via the trans-trochanteric approach, minimum four-year roentgenographic follow-up evaluations were performed on 322 hips (50%). The method of fixation was stainless steel monofilament wire in 162 cases and Co-Cr cable in 160. Trochanteric union rates were 75% (122 patients) for the wire group and 79% (126 patients) for the cable. Breakage rates of the entire trochanteric fixation construction (all three wires or cables) were 43% (68 patients) for the wire and 12% (20 patients) for the cable. Unraveled cable was seen in 56% of the hips (90 patients), and in 47% of these hips, there were no broken cables. Blinded roentgenographic analysis of the acetabulum, preformed independently, revealed that loosening of the acetabulum in the cable group was greater than in the wire group. Cables offer no significant benefit over wires and may have potential adverse effects. Generation of significant particulate debris was noted roentgenographically, and marked reaction/destruction was found at the time of revision surgery.

  18. Towards a Completely Implantable, Light-Sensitive Intraocular Retinal Prosthesis

    National Research Council Canada - National Science Library

    Humayun, M

    2001-01-01

    .... Previous studies have established the feasibility of the retinal prosthesis. Short-term tests in blind humans have shown that degenerated retina will respond to light in a way that is consistent with form vision...

  19. [Our experience with the use of Active-C cervical prosthesis].

    Science.gov (United States)

    Misik, Ferenc; Böösi, Martina; Papp, Zoltán; Padányi, Csaba; Banczerowski, Péter

    2016-09-30

    The most widely used surgical procedure in the treatment of cervical spine disc hernias have been the anterior cervical discectomy and fusion for decades. The usage of cervical disc prostheses enabled us to preserve the movements of the affected segments, hereby reducing the overexertion of the adjacent vertebrae and discs. Our goal is to follow our patients operated with Active-C prosthesis (which is used in the Institute since 2010) to gather information about the change of their complaints and about the functioning and unwanted negative effects of the prostheses. Question - Is the usage of Active-C prosthesis an efficient procedure? Between 2010 and 2013, performing the survey of neurological conditions and functional X-ray examinations. We measured the complaints of the patients using the Visual Analogue Scale, Neck Disability Index and Cervical Spine Outcomes Questionnaire. The control group consisted of patients who were operated in one segment using the fusion technique. In the study group according to the Neck Disability Index scale after 18 months, seven patients had no complaints, while twelve persons reported mild and the remaining six moderate complaints. In the control group, moderate complaints were present in four patients, while twelve patients reported mild complaints. The other eight persons showed no complaints. According to the results of the Visual Analogue Scale in the group of prosthesis, the degree of referred pain decreased from 8.6 to 1.84 one and a half years after the surgery. A decrease was observable in the case of axial pain too, from 6.6 down to 1.92 (pcervical disc prosthesis can be considered as an efficient procedure, but at the same time the advantages can only be determined in the long run, therefore further following and studies are required.

  20. Functional property of the cardiac valve prosthesis evaluated in vivo by cine-radiography

    International Nuclear Information System (INIS)

    Murakoshi, Sadaaki

    1986-01-01

    Functional property of the convexo-concave Bjoerk-Shiley cardiac valve prosthesis implanted in the mitral position of 21 patients was investigated by integrated cine-radiography repeated for a long term after operation. The maximum opening angle of the tilting disc was 58 ± 2 deg, and was not affected by atrial fibrillation nor by tachycardia up to 160 bpm. There was no change in the maximum opening angle of the disc observed during follow-up period. Good correlation between shortning of the disc opening time and increase in pulse rate suggests excellent adaptation of this prosthesis for tachycardia induced by exercise or electric pacing. However, atrial fibrillation causes time delay in disc closure immediately after prolonged R-R interval. Disc rotation alleviating disc wear was observed in all the patients whether it moves slow or quick. Dysfunction of the disc opening can be readily determined not only by measuring the maximum disc opening angle, but also by observing the characteristic movement indicated in this study. It is concluded from these results that clinical apprication for the convexo-concave Bjoerk-Shiley valve prosthesis is appropriate and cine-radiography is an useful non-invasive examination of cardiac valve prosthesis for long follow-up period. (author)