WorldWideScience

Sample records for ascochyta pisi lib

  1. Occurrence of pathotypes of Ascochyta pisi (Lib. in the Olsztyn district

    Directory of Open Access Journals (Sweden)

    Helena Furgał-Węgrzycka

    2013-12-01

    Full Text Available The causal agents of leaf and pods spot-pot of peas and field peas in the Olsztyn district was the fungus Ascochyta pisi (Lib.. Investigated isolates of A. pisi differed by macroscopic and microscopic features. From diseases leaves and pods of peas and field peas obtained also saprophitic fungi among which Alternaria alternata, Botrytis cinerea, Cladosporium c1adosporioides, Epicoccum purpurascens, Stemphylium botryosum, Sordaria fimicola and mycelia starilia were dominated. In the study of the identification and distribution of pathotypes of A. pisi five pathotypes were identified among which pathotype 2 were dominated. The identified the pathotypes differed by macroscopic and microscopic features.

  2. Studies on the susceptibility of peas and field peas cultivars to Ascochyta pisi (Lib.

    Directory of Open Access Journals (Sweden)

    Helena Furgał-Węgrzycka

    2013-12-01

    Full Text Available The aim of the work was to find the plants resistant to Ascochyta pisi causing leaf and spot-pot of peas and field peas. Fourty five cultivars of peas and field peas and 6 breeding materials were tested in field in the period 1975-1978. Cultivars: Bartel, Birte, Borek, Cebeco, Finale and Paloma were to be less susceptible. In laboratory and greenhouse conditions peas and field peas cultivares were examined for susceptible to pathotypes 2 and 4 of Ascochyta pisi. The results obtained proved that cultivars: Borel, cebeco, Finale and Paloma were to be less susceptible to two pathotypes of Ascochyta pisi.

  3. Accumulation of defence-related transcripts and cloning of a chitinase mRNA from pea leaves (Pisum sativum L.) inoculated with Ascochyta pisi Lib

    DEFF Research Database (Denmark)

    Vad, Knud; de Neergaard, Eigil; Madriz-Ordeñana, Kenneth

    1993-01-01

    The race specific resistance of pea to Ascochyta pisi Lib. was shown to be exhibited as a hypersensitive response associated with the production of polyphenolic substances in epidermal and mesophyll cells. The levels of transcripts representing a pathogenesis-related (PR) protein (chitinase......) and an enzyme of phytoalexin biosynthesis (chalcone synthase) were shown to accumulate more rapidly during the hypersensitive response than during lesion development in the compatible interaction. A full-length (1143 bp) cDNA sequence of a pea chitinase (EC 3.2.1.14) (coding for an approx. 34 500 Da protein......) was deduced by combining the overlapping sequences of three clones obtained following PCR amplification of cDNA prepared from mRNA isolated 24 h after inoculation of pea leaves with Ascochyta pisi. The combined sequences were identified as a class I chitinase corresponding to the basic A1-chitinase enzyme...

  4. Preservation methods for isolates of ascochyta blight fungi

    Directory of Open Access Journals (Sweden)

    Joanna Marcinkowska

    2014-08-01

    Full Text Available Isolates of ascochyta blight fungi, two of Ascochyta pisi, four of Mycosphaerella pinodes and four of Phoma pinodella were stored: A - on slants under mineral oil, B - on CN's medium agar disks, and as conidial suspension: C - in glycerine, D · in water. Viability and pathogenicity of recovered cultures after each consecutive year were assesed from 1991 to 1999. The compared parameters were first of all strongly influenced by the preservation method, but fungus species and number of years had a minor importance. The best for longer storage was method "A" because after 9 years the isolates were viable, highly pathogenic, and cultures recovered from them were clean. Thc method "C'' is good for short keeping (2-3 years, as conidia in vials need only small space and gave clean cultures.

  5. Generation of pea mutants for resistance to Ascochyta blight and powdery mildew and their characterization using isozyme markers [Pisum sativum L.; India

    International Nuclear Information System (INIS)

    Sharma, R.; Kant, A.; Kaushal, R.P.

    2004-01-01

    To induce resistance in pea against Ascochyta blight and powdery mildew through mutagenesis, two locally grown cultivars Lincoln and Palam Priya were subjected to three doses each of gamma rays (10, 15 and 20 kR) and chemical mutagen ethylmethane sulfonate (0.1, 0.2 and 0.3%). Reduced germination was observed in response to mutagen treatment in both cultivars. Phenotypic changes were observed in M1 and M2 generations of both the cultivars. In M2 generation twenty-seven mutants of Lincoln and sixteen of Palam Priya were found resistant to Ascochyta blight under natural epiphytotic conditions. High level of resistance in M2 generation against powdery mildew could not be achieved. Plant progenies in the M3 generation were also evaluated for resistance to Ascochyta pinodes as well as Erysiphe pisi through detached leaf technique. Six mutants of Lincoln and only one of Palam Priya were found resistant to A. pinodes. One mutant of Palam Priya (P15-3) showed resistance to both the pathogens. Increased phenylalanine ammonia lyase activity was observed in all the resistant mutants. New isoforms of peroxidase could be detected in the mutant P15-3 (Palam Priya) and also in L0.2-1 (Lincoln). However, not much variation for esterase could be observed [it

  6. Morphological characterization of fungi associated with the ascochyta blight complex and pathogenic variability of Mycosphaerella pinodes on field pea crops in central Alberta

    Directory of Open Access Journals (Sweden)

    Hafiz Ahmed

    2015-02-01

    Full Text Available Field pea crops in central Alberta were surveyed for ascochyta blight from 2011 to 2012 and fungal isolates were recovered from foliar lesions on selected plants. Cultural and microscopic characterization of the 275 isolates obtained revealed that 272 were of Mycosphaerella pinodes and three were of Phoma medicaginis var. pinodella. Ascochyta pisi or Phoma koolunga were not identified. Isolates of M. pinodes were divided into two groups, GI and GII, based on visual assessment of culture characteristics. GI isolates (light to dark, mostly gray colony color; pycnidial distribution radial and concentric; conidia 10.5–14.5 × 4.2–6.2 μm most with one septum, occasionally two, constricted at the septum; spore mass light buff to flesh color were predominant (83%, while GII isolates (dark to gray colony color; pycnidia abundant; conidia 8–16 × 3.5–6.2 μm most with 1 septum, constricted at the septum; spore mass light buff to flesh color were less common (17%. The cultures of GII isolates were similar to recent descriptions of A. pisi, but they differed in spore color. In a host differential study, 13 pathotypes of M. pinodes were identified from 110 single-spore isolates. Pathotype I was predominant (88 isolates and virulent on all nine differential genotypes. The other pathotypes (pathotypes II–XIII were rare (1–6 isolates of each. Comparison of the present results with earlier studies suggests that pathotype I has been prevalent for many years, and that its aggressiveness on the host differentials has increased over time. Emphasis should be placed on breeding for resistance to M. pinodes in field pea cultivars intended for deployment in central Alberta.

  7. Notes on some species of Ascochyta (Coelomycetes new and rare for Poland

    Directory of Open Access Journals (Sweden)

    Monika Kozłowska

    2014-08-01

    Full Text Available Three species of Ascochyta (conidial fungi, Coelomycetes are described in the paper. Ascochyta urticae A. L. Smith et Ramsbottom (on Urtica dioica L. and Ascochyta phomoides Saccardo (on Aegopodium podagraria L. are species new for Poland. Ascochyta podagrariae Bresadola (on A. podagraria L. is known from one locality only. All species are rarely noted in the world.

  8. Sources of resistance in chickpea (cicer arietinum l.) land races against ascochyta rabiei causal agent of ascochyta blight disease

    International Nuclear Information System (INIS)

    Duzdemir, O.; Selvi, B.; Yanar, Y.

    2014-01-01

    Ascochyta blight disease, caused by the fungus Ascochyta rabiei, is a major yield limiting factor of chickpea in Turkey and around the world. This study was conducted to identify sources of genetic resistance against chickpea blight caused by Ascochyta rabiei. For this purpose, 68 chickpea land races of different origins were evaluated in both field and growth chamber conditions during 2008-2009 growing seassons. Two standard cultivars were used as a reference, Inci (resistant) and Canitez (susceptible). Disease severity scoring was conducted on a 1-9 rating scale 21 days after inoculation in growth chamber test and at flowering and pot filling stages in field tests. Analysis of variance (ANOVA) test showed a significant difference among the chickpea landraces in ascochyta blight resistance at p<0.05. None of the chickpea land races was highly resistant to the pathogen in growth chamber and field conditions. Only two landraces (10A and 28B) were moderately resistant to the disease. Some of the landraces resulted in a particular plant to exhibit no disease symptoms, indicating that the variation within chickpea land races was high. Therefore, seeds of this plant were harvested separately and preserved for further evaluations. (author)

  9. Genotype-Dependent Interaction of Lentil Lines with Ascochyta lentis

    Directory of Open Access Journals (Sweden)

    Ehsan Sari

    2017-05-01

    Full Text Available Ascochyta blight of lentil is a prevalent disease in many lentil producing regions and can cause major yield and grain quality losses. The most environmentally acceptable and economically profitable method of control is to develop varieties with high levels of durable resistance. Genetic studies to date suggest that ascochyta blight resistance genes (R-gene in lentil lines CDC Robin, ILL 7537, 964a-46, and ILL 1704 are non-allelic. To understand how different R-genes manifest resistance in these genotypes and an accession of Lens ervoides, L-01-827A, with high level of resistance to ascochyta blight, cellular and molecular defense responses were compared after inoculation with the causal pathogen Ascochyta lentis. Pathogenicity testing of the resistant lines to A. lentis inoculation revealed significantly lower disease severity on CDC Robin and ILL 7537 compared to ILL 1704 and 964a-46, and no symptoms of disease were observed on L-01-827A. Histological examinations indicated that cell death triggered by the pathogen might be disrupted as a mechanism of resistance in CDC Robin. In contrast, limiting colonization of epidermal cells by A. lentis is a suggested mechanism of resistance in 964a-46. A time-series comparison of the expressions of hallmark genes in salicylic acid (SA and jasmonic acid (JA signal transduction pathways between CDC Robin and 964a-46 was conducted. These partially resistant genotypes differed in the timing and the magnitude of SA and JA signaling pathway activation. The SA signaling pathway was only triggered in 964a-46, whereas the JA pathway was triggered in both partially resistant genotypes CDC Robin and 964a-46. The expression of JA-associated genes was lower in 964a-46 than CDC Robin. These observations corroborate the existence of diverse ascochyta blight resistance mechanisms in lentil genotypes carrying different R-genes.

  10. Resistance to rusts (uromyces pisi and u. viciae-fabae) in pea

    OpenAIRE

    Barilli, Eleonora; Sillero, Josefina C.; Prats, Elena; Rubiales, Diego

    2014-01-01

    Pea is the second most important food legume crop in the world. Rust is a pea disease widely distributed, particularly in regions with warm, humid weather. Pea rust can be incited by Uromyces viciae-fabae and by U. pisi. U. viciae-fabae prevails in tropical and subtropical regions such as India and China, while U. pisi prevails in temperate regions. Chemical control of rust is possible, but the use of host plant resistance is the most desired means of rust control. In this paper we revise and...

  11. Genetic mapping of ascochyta blight resistance in chickpea (Cicer arietinum L.) using a simple sequence repeat linkage map.

    Science.gov (United States)

    Tar'an, B; Warkentin, T D; Tullu, A; Vandenberg, A

    2007-01-01

    Ascochyta blight, caused by the fungus Ascochyta rabiei (Pass.) Lab., is one of the most devastating diseases of chickpea (Cicer arietinum L.) worldwide. Research was conducted to map genetic factors for resistance to ascochyta blight using a linkage map constructed with 144 simple sequence repeat markers and 1 morphological marker (fc, flower colour). Stem cutting was used to vegetatively propagate 186 F2 plants derived from a cross between Cicer arietinum L. 'ICCV96029' and 'CDC Frontier'. A total of 556 cutting-derived plants were evaluated for their reaction to ascochyta blight under controlled conditions. Disease reaction of the F1 and F2 plants demonstrated that the resistance was dominantly inherited. A Fain's test based on the means and variances of the ascochyta blight reaction of the F3 families showed that a few genes were segregating in the population. Composite interval mapping identified 3 genomic regions that were associated with the reaction to ascochyta blight. One quantitative trait locus (QTL) on each of LG3, LG4, and LG6 accounted for 13%, 29%, and 12%, respectively, of the total estimated phenotypic variation for the reaction to ascochyta blight. Together, these loci controlled 56% of the total estimated phenotypic variation. The QTL on LG4 and LG6 were in common with the previously reported QTL for ascochyta blight resistance, whereas the QTL on LG3 was unique to the current population.

  12. Cutinase of Fusarium solani F. sp. pisi: mechanism of induction and relatedness to other Fusarium species

    International Nuclear Information System (INIS)

    Woloshuk, C.P.

    1986-01-01

    Three studies were made on the extracellular cutinase of the phytopathogenic fungus Fusarium solani f. sp. pisi. I. The production of cutinase was found to be induced in spores of F. solani f. sp. pisi, strain T-8, by cutin and cutin hydrolysate. Fractionation and analysis of the cutin hydrolysate indicated that dihydroxy-C 16 acid and trihydroxy-C 18 acid were the cutin monomers most active for inducing cutinase. Measurement of cutinase-specific RNA levels by dot-blot hybridization with a [ 32 P]-labeled cutinase cDNA showed that the cutinase gene transcripts could be detected within 15 min after addition of the inducers. The results indicated that the fungal spores have the capacity to recognize the unique monomer components of the plant cuticle and rapidly respond by the synthesis of cutinase. II. Analysis of the genomic DNA's of seven strains of F. solani f. sp. pisi indicated that both high and low cutinase-producing strains contain at least one copy of the cutinase structural gene and a homologous promoter region. The data suggest a different promoter sequence exists in these additional copies. III. Relatedness of five phytopathogenic Fusarium species to F. solani f. sp. pisi was determined by their cutinase antigenic properties and gene homologies of cutinase cDNA from F. solani f. sp. pisi. The results suggest that formae specialis of F. solani are phylogenetically identical and that F. solani is quite distinct from the other Fusarium species tested

  13. il verbo di bodhisattva». de pisis, le avanguardie, l'oriente

    African Journals Online (AJOL)

    User

    Il Verbo di Bodhisatthva (1917), written at the end of de Pisis' avant-garde years, starts from the ... Egli seguiva molto la rivista dato che, nel periodo in cui la diresse De ..... Blavatsky, sosteneva l'ipotesi secondo la quale, alla base di tutte le.

  14. Lathyrus sativus transcriptome resistance response to Ascochyta lathyri investigated by deepSuperSAGE analysis

    Science.gov (United States)

    Almeida, Nuno F.; Krezdorn, Nicolas; Rotter, Björn; Winter, Peter; Rubiales, Diego; Vaz Patto, Maria C.

    2015-01-01

    Lathyrus sativus (grass pea) is a temperate grain legume crop with a great potential for expansion in dry areas or zones that are becoming more drought-prone. It is also recognized as a potential source of resistance to several important diseases in legumes, such as ascochyta blight. Nevertheless, the lack of detailed genomic and/or transcriptomic information hampers further exploitation of grass pea resistance-related genes in precision breeding. To elucidate the pathways differentially regulated during ascochyta-grass pea interaction and to identify resistance candidate genes, we compared the early response of the leaf gene expression profile of a resistant L. sativus genotype to Ascochyta lathyri infection with a non-inoculated control sample from the same genotype employing deepSuperSAGE. This analysis generated 14.387 UniTags of which 95.7% mapped to a reference grass pea/rust interaction transcriptome. From the total mapped UniTags, 738 were significantly differentially expressed between control and inoculated leaves. The results indicate that several gene classes acting in different phases of the plant/pathogen interaction are involved in the L. sativus response to A. lathyri infection. Most notably a clear up-regulation of defense-related genes involved in and/or regulated by the ethylene pathway was observed. There was also evidence of alterations in cell wall metabolism indicated by overexpression of cellulose synthase and lignin biosynthesis genes. This first genome-wide overview of the gene expression profile of the L. sativus response to ascochyta infection delivered a valuable set of candidate resistance genes for future use in precision breeding. PMID:25852725

  15. Lathyrus sativus transcriptome resistance response to Ascochyta lathyri as reviewed by deepSuperSAGE analysis

    Directory of Open Access Journals (Sweden)

    Nuno Felipe Almeida

    2015-03-01

    Full Text Available Lathyrus sativus (grass pea is a temperate grain legume crop with a great potential for expansion in dry areas or zones that are becoming more drought-prone. It is also recognized as a potential source of resistance to several important diseases in legumes, such as ascochyta blight. Nevertheless, the lack of detailed genomic and/or transcriptomic information hampers further exploitation of grass pea resistance-related genes in precision breeding. To elucidate the pathways differentially regulated during ascochyta-grass pea interaction and to identify resistance candidate genes, we compared the early response of the leaf gene expression profile of a resistant L. sativus genotype to Ascochyta lathyri infection with a non-inoculated control sample from the same genotype employing deepSuperSAGE. This analysis generated 14.387 UniTags of which 95.7% mapped to a reference grass pea/rust interaction transcriptome. From the total mapped UniTags, 738 were significantly differentially expressed between control and inoculated leaves. The results indicate that several gene classes acting in different phases of the plant/pathogen interaction are involved in the L. sativus response to A. lathyri infection. Most notably a clear up-regulation of defense-related genes involved in and/or regulated by the ethylene pathway was observed. There was also evidence of alterations in cell wall metabolism indicated by overexpression of cellulose synthase and lignin biosynthesis genes. This first genome-wide overview of the gene expression profile of the L. sativus response to ascochyta infection delivered a valuable set of candidate resistance genes for future use in precision breeding.

  16. An Update on Genetic Resistance of Chickpea to Ascochyta Blight

    Directory of Open Access Journals (Sweden)

    Mamta Sharma

    2016-03-01

    Full Text Available Ascochyta blight (AB caused by Ascochyta rabiei (Pass. Labr. is an important and widespread disease of chickpea (Cicer arietinum L. worldwide. The disease is particularly severe under cool and humid weather conditions. Breeding for host resistance is an efficient means to combat this disease. In this paper, attempts have been made to summarize the progress made in identifying resistance sources, genetics and breeding for resistance, and genetic variation among the pathogen population. The search for resistance to AB in chickpea germplasm, breeding lines and land races using various screening methods has been updated. Importance of the genotype × environment (GE interaction in elucidating the aggressiveness among isolates from different locations and the identification of pathotypes and stable sources of resistance have also been discussed. Current and modern breeding programs for AB resistance based on crossing resistant/multiple resistant and high-yielding cultivars, stability of the breeding lines through multi-location testing and molecular marker-assisted selection method have been discussed. Gene pyramiding and the use of resistant genes present in wild relatives can be useful methods in the future. Identification of additional sources of resistance genes, good characterization of the host–pathogen system, and identification of molecular markers linked to resistance genes are suggested as the key areas for future study.

  17. Ocorrência e sintomas da mancha de Ascochyta em feijão-vagem Occurrence and symptoms of Ascochyta blight on snap bean

    Directory of Open Access Journals (Sweden)

    Maria Aparecida de Souza Tanaka

    1996-01-01

    Full Text Available A mancha de ascochita (Ascochyta phaseolorum Sacc. foi identificada como uma das principais doenças do feijão-vagem (Phaseolus vulgaris L., na região de Itatiba (SP, em levantamento realizado de abril de 1991 a março de 92. Seus sintomas são manchas foliares arredondadas, tipicamente zonadas e de tamanho variável, necrosando, às vezes, extensas áreas do limbo e provocando desfolha prematura. Associado a esse sintoma foliar, o patógeno pode causar lesões nas hastes, pecíolos e vagens, assumindo proporções severas. As lesões necróticas das hastes podem estrangula-las e provocar a morte da planta acima da região afetada. Nas vagens, as lesões tendem a ser circulares e zonadas, como as das folhas, porém os anéis concêntricos são menos evidentes. Isolamentos, características culturais e morfológicas e testes de patogenicidade permitiram diagnosticar a moléstia, que vinha sendo confundida com a mancha foliar de alternária, ou com a podridão de macrofomina, quando atacava a parte inferior da haste. A identificação do patógeno, por ter permitido o diagnóstico preciso da doença. poderá embasar o emprego de métodos adequados de controle.A severe Ascochyta blight (Ascochyta phaseolorum Sacc., was found during a survey carried out in farmer's fields of snap bean (Phaseolus vulgaris L. at Itatiba county, São Paulo State, Brazil. Foliar lesions were usually circular to irregular shaped, brown to dark brown and usually contained concentric circles of picnidia. These lesions often blighted the entire leaves, that die and fall. The pathogen also infected the stems, petioles and pods, and the disease incidence ranged from trace to severe. The stems and petioles lesions were elongated and cankerous, often girdling them, killing the plant above the infected region. The pod lesions were initially circular and zonate, as the foliar spots, but the concentric circles are of little evidence. Diagnosis were confirmed by isolation

  18. Future prospects for ascochyta blight resistance breeding in cool season food legumes

    Directory of Open Access Journals (Sweden)

    Diego eRubiales

    2012-02-01

    Full Text Available Legume cultivation is strongly hampered by the occurrence of ascochyta blights. Strategies of control have been developed but only marginal successes have been achieved. Breeding for disease resistance is regarded the most cost efficient method of control. Significant genetic variation for disease resistance exists in most legume crops with numerous germplasm lines maintained, providing an excellent resource for plant breeders. Fast and reliable screening methods have been adjusted to fulfil breeding programmes needs. However, the complex inheritance controlled quantitatively by multiple genes, have been difficult to manipulate. Successful application of biotechnology to ascochyta blight resistance breeding in legume crops will facilitate both a good biological knowledge of the crops and of the mechanisms underlying resistance. The current focus in applied breeding is leveraging biotechnological tools to develop more and better markers to speed up the delivery of improved cultivars to the farmer. To date, however, progress in marker development and delivery of useful markers has been slow. The limited saturation of the genomic regions bearing putative QTLs in legume crops makes difficult to identify the most tightly-linked markers

  19. Abstracts of oral and poster presentations given at the Ascochyta 2012 Workshop, Córdoba, Spain, 22–26 April 2012

    Directory of Open Access Journals (Sweden)

    Teresa Millan

    2013-05-01

    Full Text Available The third International Ascochyta Workshop was held in Córdoba, Spain 22 - 26 April 2012. This meeting was attended by 70 participants, and 33 oral presentations, 17 posters and 4 invited speeches were presented dealing with Ascochyta blights of the cool season food legumes (peas, lentils, chickpeas and faba beans. In addition, a special session was held on “Food legumes Research in North Africa”. Abstracts of the oral presentations and the posters of the congress are presented in this issue.

  20. mQTL-seq and classical mapping implicates the role of an AT-HOOK MOTIF CONTAINING NUCLEAR LOCALIZED (AHL) family gene in Ascochyta blight resistance of chickpea.

    Science.gov (United States)

    Kumar, Kamal; Purayannur, Savithri; Kaladhar, Vemula Chandra; Parida, Swarup Kumar; Verma, Praveen Kumar

    2018-03-01

    Ascochyta blight (AB) caused by the fungal pathogen Ascochyta rabiei is a serious foliar disease of chickpea (Cicer arietinum L.). Despite many genetic studies on chickpea-Ascochyta interaction, genome-wide scan of chickpea for the identification of AB-associated quantitative trait loci (QTLs) and their gene(s) has not been accomplished. To elucidate narrow QTLs for AB resistance, here, we report the use of multiple QTL-sequencing approach on 2 sets of extreme AB phenotype bulks derived from Cicer intraspecific and interspecific crosses. Two major QTLs, qABR4.1 and qABR4.2, and a minor QTL, qABR4.3, were identified on assembled chickpea pseudomolecule 4. We narrowed qABR4.1 to a "robust region" at 4.568-4.618 Mb through mapping on a larger intraspecific cross-derived population and comparative analysis. Among 4 genes, the CaAHL18 gene showed higher expression under Ascochyta stress in AB resistant parent suggesting that it is the candidate gene under "robust qABR4.1." Dual-luciferase assay with CaAHL18 polymorphic cis-regulatory sequences showed that allelic variation is associated with higher expression. Thus, our findings on chickpea-Ascochyta interaction have narrowed down AB resistance associated QTLs on chickpea physical map. The narrowed QTLs and gene-associated markers will help in biotechnological and breeding programs for chickpea improvement. © 2018 John Wiley & Sons Ltd.

  1. Conductimetric detection of Pseudomonas syringae pathover pisi in pea seeds and soft rot Erwinia spp. on potato tubers

    NARCIS (Netherlands)

    Fraaije, B.

    1996-01-01


    Pea bacterial blight and potato blackleg are diseases caused by Pseudomonas syringae pv. pisi ( Psp ) and soft rot Erwinia spp., respectively. The primary source of inoculum for these bacteria is

  2. Synthesis of UDP-apiose in Bacteria: The marine phototroph Geminicoccus roseus and the plant pathogen Xanthomonas pisi.

    Directory of Open Access Journals (Sweden)

    James Amor Smith

    Full Text Available The branched-chain sugar apiose was widely assumed to be synthesized only by plant species. In plants, apiose-containing polysaccharides are found in vascularized plant cell walls as the pectic polymers rhamnogalacturonan II and apiogalacturonan. Apiosylated secondary metabolites are also common in many plant species including ancestral avascular bryophytes and green algae. Apiosyl-residues have not been documented in bacteria. In a screen for new bacterial glycan structures, we detected small amounts of apiose in methanolic extracts of the aerobic phototroph Geminicoccus roseus and the pathogenic soil-dwelling bacteria Xanthomonas pisi. Apiose was also present in the cell pellet of X. pisi. Examination of these bacterial genomes uncovered genes with relatively low protein homology to plant UDP-apiose/UDP-xylose synthase (UAS. Phylogenetic analysis revealed that these bacterial UAS-like homologs belong in a clade distinct to UAS and separated from other nucleotide sugar biosynthetic enzymes. Recombinant expression of three bacterial UAS-like proteins demonstrates that they actively convert UDP-glucuronic acid to UDP-apiose and UDP-xylose. Both UDP-apiose and UDP-xylose were detectable in cell cultures of G. roseus and X. pisi. We could not, however, definitively identify the apiosides made by these bacteria, but the detection of apiosides coupled with the in vivo transcription of bUAS and production of UDP-apiose clearly demonstrate that these microbes have evolved the ability to incorporate apiose into glycans during their lifecycles. While this is the first report to describe enzymes for the formation of activated apiose in bacteria, the advantage of synthesizing apiose-containing glycans in bacteria remains unknown. The characteristics of bUAS and its products are discussed.

  3. ZoneLib

    DEFF Research Database (Denmark)

    Jessen, Jan Jacob; Schiøler, Henrik

    2006-01-01

    We present a dynamic model for climate in a livestock building divided into a number of zones, and a corresponding modular Simulink library (ZoneLib). While most literature in this area consider air flow as a control parameter we show how to model climate dynamics using actual control signals...... development of ZoneLib....

  4. Occurrence of pathotypes of Ascochyta pinodes (Jones in the Olsztyn district

    Directory of Open Access Journals (Sweden)

    Helena Furgał-Węgrzycka

    2013-12-01

    Full Text Available The causal agent of leaf and pods spot-pot of peas and field peas in the Olsztyn district was the fungus Ascochyta pinodes (Jones. Investigated isolates of A. pinoides different by macroscopic and microscopic features. From diseased leaves and pods of peas and field peas saprophytic fungi were also obtained. Among them Alternaria alternata, Cladosporium cladosporioides, Epicoccum purpurascens, Stemphylium botryosum, Sordaria fimicola and mycelia sterilia were dominant. In the study on the identification and distribution of pathotypes of A. pinodes (Jones six pathotypes were identified among which pathotypes 3 dominated. The identified pathotypes differed by macroscopic and microscopic features.

  5. Laboratory invesitgations of variability of Ascochyta fabae Speg. isolates obtained from horse bean

    Directory of Open Access Journals (Sweden)

    Antoni Józef Filipowicz

    2014-08-01

    Full Text Available Fifty five isolates of Ascochyta fabae Speg. were investigated. They were selected from 1650 isolates of this fungus obtained from horse bean seeds in 1974-1976. All the isolates grew and sporulated on Potato Dextrose Agar, Malt Agar and Horse Bean Agar. The rate of their growth amounted to 1-4 mm per 24 hours. The variability of isolates in size of pycnidia and conidia and number of sepia was noticed. A few spores with untypical shapes were observed as well.

  6. The thermal stability of the Fusarium solani pisi cutinase as a function of pH

    OpenAIRE

    Petersen, Steffen B; Fojan, Peter; Petersen, Evamaria I; Petersen, Maria Teresa Neves

    2001-01-01

    We have investigated the thermal stability of the Fusarium solani pisi cutinase as a function of pH, in the range from pH 2–12. Its highest enzymatic activity coincides with the pH-range at which it displays its highest thermal stability. The unfolding of the enzyme as a function of pH was investigated by microcalorimetry. The ratio between the calorimetric enthalpy (ΔHcal) and the van′t Hoff enthalpy (ΔHv) obtained, is far from unity, indicating that cutinase does not exhibit a simple...

  7. Effects of nitrogen availability and spore concentration on the biocontrol activity of Ascochyta caulina in common lambsquarters (Chenopodium album)

    NARCIS (Netherlands)

    Ghorbani, R.; Scheepens, P.C.; Zweerde, van der W.; Leifert, C.; McDonald, A.J.S.; Seel, W.

    2002-01-01

    Common lambsquarters is an annual weed of many important crops. Ascochyta caulina is a plant pathogenic fungus that causes necrotic lesions on the leaves and stems of common lambsquarters. The objective of the present study was to estimate the effect of plant N supply on the biocontrol activity of

  8. Irradiation process validation in the new conveyor system installed at PISI: special dosimetry

    International Nuclear Information System (INIS)

    Pantano, Barbara P.; Docters, Andrea S.

    2009-01-01

    Semi Industrial Irradiation Plant (PISI) is a multipurpose facility which uses 60 Co sources to treat different products with numerous purposes, such as sterilization of medical devices, pharmaceutical and veterinarian products; control of pathogenic microorganisms, shelf-life extension and insect disinfestation of food, among others. In order to achieve the desired effect, the product is carried inside the irradiation chamber by means of a conveyor system, and it is exposed to radiation following a pre-established path. The recent installation of a new conveyor system at PISI demands the execution of a thorough validation programme. The scope of this presentation is to describe the dose mapping tasks that will be performed in order to characterize the irradiator and its new conveyor system with respect to distribution and variability of dose, complying with international standards on good irradiation practices. Information about the distribution and variability of dose in a product irradiated under defined conditions will allow the obtaining of process parameters which will conform the process specifications in future routine irradiations. The initial stages of the Validation Programme are the Installation Qualification, the Operational Qualification (OQ) and the Performance Qualification (PQ). To accomplish the IQ diverse tests are being carried out at PISI in order to verify that the system has been installed and is operating according to its technical specifications. Both OQ and PQ require dose mapping on simulated and real product, respectively. Dose mapping consists on placing dosimeters on a process load of homogeneous material -under certain irradiator and process parameters- according to a three-dimensional pre-established placement pattern. Since the replacement of the conveyor system introduces a significant modification in the source-to-product geometry, therefore in dose distribution, there is no reference dosimetry data available, so a more exhaustive

  9. Underwater inverse LIBS (iLIBS) for marine archaeology

    Science.gov (United States)

    Asmus, J.; Magde, M.; Elford, J.; Magde, D.; Parfenov, V.

    2013-05-01

    In recent years there have been enormous advances in nautical archaeology through developments in SONAR technologies as well as in manned and robotic submersible vehicles. The number of sunken vessel discoveries has escalated in many of the seas of the world in response to the widespread application of these and other new tools. Customarily, surviving artifacts within the debris field of a wreck are collected and then moved to laboratories, centers, or institutions for analyses and possible conservation. Frequently, the conservation phase involves chemical treatments to stabilize an artefact to standard temperature, pressure, and humidity instead of an undersea environment. Many of the artefacts encountered at an underwater site are now characterized and restored in-situ in accordance with modern trends in art conservation. Two examples of this trend are exemplified by the resting place of the wreck of the Titanic in the Atlantic and the Cancun Underwater Park in the Caribbean Sea. These two debris fields have been turned into museums for diving visitors. Several research groups have investigated the possibility of adapting the well-established analytical tool Laser Induced Breakdown Spectroscopy (LIBS) to in-situ elemental analyses of underwater cultural, historic, and archaeological artefacts where discovered, rather than as a phase of a salvage operation. As the underwater laser ablation associated with LIBS generates a "snowplough" shockwave within the aqueous matrix, the atomic emission spectrum is usually severely attenuated in escaping from the target. Consequently, probative experiments to date generally invoke a submerged air chamber or air jet to isolate water from the interaction zone as well as employ more complex double-pulse lasers. These measures impose severe logistical constraints on the examination of widely dispersed underwater artefacts. In order to overcome this constraint we report on water-immersion LIBS experiments performed with oblique

  10. Influence of inoculation with ascochyta lentis on mineral contents (Na, Ca, Mg, Cu, and Fe) of susceptible and resistant lines of lentil (Lens culinaris medik.)

    International Nuclear Information System (INIS)

    Sahi, S.T.; Ghazanfar, M.U.; Habib, A.; Wakil, W.

    2010-01-01

    An experiment was conducted to determine the mineral contents of the healthy and inoculated plant of lentil and their relationship toward the Ascochyta lentis disease. The results revealed that magnesium, copper and zinc contents of un-inoculated lentil lines, included in susceptible group were higher than those included in resistant group whereas, sodium, calcium and iron contents were more in the resistant as compared to the susceptible group. Upon inoculation with Ascochyta lentis, the cause of lentil blight disease, sodium, calcium, zinc, copper and iron contents increased invariably in both the susceptible and resistant groups of lentil lines. On the other hand, magnesium contents increased in susceptible group but decreased in resistant group. The over all results proved that considerable variation exists in micro mineral contents of resistant and susceptible lines of lentil. (author)

  11. Transcription Factor Repertoire of Necrotrophic Fungal Phytopathogen Ascochyta rabiei: Predominance of MYB Transcription Factors As Potential Regulators of Secretome

    Directory of Open Access Journals (Sweden)

    Sandhya Verma

    2017-06-01

    Full Text Available Transcription factors (TFs are the key players in gene expression and their study is highly significant for shedding light on the molecular mechanisms and evolutionary history of organisms. During host–pathogen interaction, extensive reprogramming of gene expression facilitated by TFs is likely to occur in both host and pathogen. To date, the knowledge about TF repertoire in filamentous fungi is in infancy. The necrotrophic fungus Ascochyta rabiei, that causes destructive Ascochyta blight (AB disease of chickpea (Cicer arietinum, demands more comprehensive study for better understanding of Ascochyta-legume pathosystem. In the present study, we performed the genome-wide identification and analysis of TFs in A. rabiei. Taking advantage of A. rabiei genome sequence, we used a bioinformatic approach to predict the TF repertoire of A. rabiei. For identification and classification of A. rabiei TFs, we designed a comprehensive pipeline using a combination of BLAST and InterProScan software. A total of 381 A. rabiei TFs were predicted and divided into 32 fungal specific families of TFs. The gene structure, domain organization and phylogenetic analysis of abundant families of A. rabiei TFs were also carried out. Comparative study of A. rabiei TFs with that of other necrotrophic, biotrophic, hemibiotrophic, symbiotic, and saprotrophic fungi was performed. It suggested presence of both conserved as well as unique features among them. Moreover, cis-acting elements on promoter sequences of earlier predicted A. rabiei secretome were also identified. With the help of published A. rabiei transcriptome data, the differential expression of TF and secretory protein coding genes was analyzed. Furthermore, comprehensive expression analysis of few selected A. rabiei TFs using quantitative real-time polymerase chain reaction revealed variety of expression patterns during host colonization. These genes were expressed in at least one of the time points tested post

  12. Using LIBS Method in Safeguards

    International Nuclear Information System (INIS)

    Kovacs-Szeles, E.; Almasi, I.

    2015-01-01

    Laser-Induced Breakdown Spectroscopy (LIBS) is a type of atomic emission spectroscopic technique which is capable to detect almost all the elements from the periodic table in different sample types (solid, liquid or gas). Other advantage of the technique is that a LIBS analysis is much faster than a conventional laboratory technique. Beside the easy usability and fastness of the system the main advantages of the technique is that portable systems are also available. Using a so-called ''backpack'' version in-field analysis can be carried out. Therefore, LIBS is a more and more popular technique also e.g., in the nuclear analytics due to its several advantages. It is also tested for Safeguards purposes as a novel technology. In this work development and test of a portable LIBS system is discussed in detail. Detector system with higher resolution and specific software for evaluation of uranium isotope composition has been developed. Different kind of uranium fuel pellets with various enrichments was analyzed as test samples. Concerning the test measurements the developed LIBS instrument was found well-applicable for analysis of Safeguards samples and determination of higher enrichment of uranium in-field. The method is rapid and simple enough for short in-field sample analysis. (author)

  13. Expanding Library Services and Instruction Through LibGuides.

    Science.gov (United States)

    Ream, Tim; Parker-Kelly, Darlene

    2016-01-01

    Beginning in 2012, the Charles R. Drew University (CDU) Health Sciences Library used LibGuides in a number of innovative ways. Librarians constructed e-book databases, in-depth tutorials on technology-related topics, and web pages highlighting special events. To assess similar LibGuides innovation, CDU librarians developed an eight-question survey distributed to health sciences and hospital libraries throughout Southern California and Arizona. Results showed that libraries used LibGuides primarily to deliver access to online resources and to provide supplementary materials supporting instruction. Responses also revealed that many libraries had not yet adopted LibGuides. These findings were analyzed and compared to past and current LibGuides design at CDU.

  14. Effect of Atmospheric Conditions on LIBS Spectra

    OpenAIRE

    Effenberger, Andrew J.; Scott, Jill R.

    2010-01-01

    Laser-induced breakdown spectroscopy (LIBS) is typically performed at ambient Earth atmospheric conditions. However, interest in LIBS in other atmospheric conditions has increased in recent years, especially for use in space exploration (e.g., Mars and Lunar) or to improve resolution for isotopic signatures. This review focuses on what has been reported about the performance of LIBS in reduced pressure environments as well as in various gases other than air.

  15. Effect of Atmospheric Conditions on LIBS Spectra

    Science.gov (United States)

    Effenberger, Andrew J.; Scott, Jill R.

    2010-01-01

    Laser-induced breakdown spectroscopy (LIBS) is typically performed at ambient Earth atmospheric conditions. However, interest in LIBS in other atmospheric conditions has increased in recent years, especially for use in space exploration (e.g., Mars and Lunar) or to improve resolution for isotopic signatures. This review focuses on what has been reported about the performance of LIBS in reduced pressure environments as well as in various gases other than air. PMID:22399914

  16. Combining Ascochyta blight and Botrytis grey mould resistance in chickpea through interspecific hybridization

    Directory of Open Access Journals (Sweden)

    Livinder KAUR

    2013-05-01

    Full Text Available Ascochyta blight (AB caused by Ascochyta rabiei (Pass. Labr. and Botrytis grey mould (BGM caused by Botrytis cinerea (Pers. ex Fr. are important diseases of the aerial plant parts of chickpea in most chickpea growing areas of the world. Although conventional approaches have contributed to reducing disease, the use of new technologies is expected to further reduce losses through these biotic stresses. Reliable screening techniques were developed: ‘field screening technique’ for adult plant screening, ‘cloth chamber technique’ and ‘growth chamber technique’ for the study of races of the pathogen and for segregating generations. Furthermore, the ‘cut twig technique’ for interspecific population for AB and BGM resistance was developed. For introgression of high levels of AB and BGM resistance in cultivated chickpea from wild relatives, accessions of seven annual wild Cicer spp. were evaluated and identified: C. judaicum accessions 185, ILWC 95 and ILWC 61, C. pinnatifidum accessions 188, 199 and ILWC 212 as potential donors. C. pinnatifidum accession188 was crossed with ICCV 96030 and 62 F9 lines resistant to AB and BGM were derived. Of the derived lines, several are being evaluated for agronomic traits and yield parameters while four lines, GL 29029, GL29206, GL29212, GL29081 possessing high degree of resistance were crossed with susceptible high yielding cultivars BG 256 to improve resistance and to undertake molecular studies. Genotyping of F2 populations with SSR markers from the chickpea genome was done to identify markers potentially linked with AB and BGM resistance genes. In preliminary studies, of 120 SSR markers used, six (Ta 2, Ta 110, Ta 139, CaSTMS 7, CaSTMS 24 and Tr 29 were identified with polymorphic bands between resistant derivative lines and the susceptible parent. The study shows that wild species of Cicer are the valuable gene pools of resistance to AB and BGM. The resistant derivative lines generated here can

  17. A cosmology forecast toolkit — CosmoLib

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Zhiqi, E-mail: zqhuang@cita.utoronto.ca [CEA, Institut de Physique Théorique, Orme des Merisiers, Saint-Aubin, 91191 Gif-sur-Yvette Cédex (France)

    2012-06-01

    The package CosmoLib is a combination of a cosmological Boltzmann code and a simulation toolkit to forecast the constraints on cosmological parameters from future observations. In this paper we describe the released linear-order part of the package. We discuss the stability and performance of the Boltzmann code. This is written in Newtonian gauge and including dark energy perturbations. In CosmoLib the integrator that computes the CMB angular power spectrum is optimized for a l-by-l brute-force integration, which is useful for studying inflationary models predicting sharp features in the primordial power spectrum of metric fluctuations. As an application, CosmoLib is used to study the axion monodromy inflation model that predicts cosine oscillations in the primordial power spectrum. In contrast to the previous studies by Aich et al. and Meerburg et al., we found no detection or hint of the osicllations. We pointed out that the CAMB code modified by Aich et al. does not have sufficient numerical accuracy. CosmoLib and its documentation are available at http://www.cita.utoronto.ca/∼zqhuang/CosmoLib.

  18. Holocene closure of Lib Pond, Marshall Islands.

    Directory of Open Access Journals (Sweden)

    Conor L Myhrvold

    Full Text Available Well-preserved sediment from closed water bodies of atolls such as Lib Pond are rare opportunities to reconstruct the past regional climate, which pieced together across a latitude and longitude range identify the range of movement patterns of wider scale climate phenomena such as the Intertropical Convergence Zone (ITCZ and El Niño Southern Oscillation (ENSO. We conducted the first physico-chemical survey of Lib Pond, a shallow, closed-water saline lake located on remote and difficult to access Lib Island in the Marshall Islands at 8° 18' 48.99″ N, 167 22' 51.90″ E in the Pacific Ocean, in July 2009. We performed a bathymetric survey, recorded salinity, dissolved oxygen, pH, and temperature profiles, monitored the tidal variability, and conducted a vegetation survey surrounding the lake. From bathymetric data we calculated the lake volume, which we used to estimate the lake's salt budget, and ultimately the residence time of water in the lake basin. We took a series of sediment cores from the lake, cores which indicate Lib Island's changing environment and climate. Radiocarbon measurements determined sediment age, and reveal significant mixing over the last 2 ka of deposition. We conclude that prior to 3 ka, Lib Island was an atoll with a central lagoon connected to the open ocean, which was then closed off from the open ocean to form the brackish system that exists today. We predict that the sediment accumulation in Lib Pond evident today will continue. As seawater is inhibited from exchanging with fresh water, Lib Pond will become a shallower lake with increasingly fresh water.

  19. Holocene closure of Lib Pond, Marshall Islands.

    Science.gov (United States)

    Myhrvold, Conor L; Janny, Fran; Nelson, Daniel; Ladd, S Nemiah; Atwood, Alyssa; Sachs, Julian P

    2014-01-01

    Well-preserved sediment from closed water bodies of atolls such as Lib Pond are rare opportunities to reconstruct the past regional climate, which pieced together across a latitude and longitude range identify the range of movement patterns of wider scale climate phenomena such as the Intertropical Convergence Zone (ITCZ) and El Niño Southern Oscillation (ENSO). We conducted the first physico-chemical survey of Lib Pond, a shallow, closed-water saline lake located on remote and difficult to access Lib Island in the Marshall Islands at 8° 18' 48.99″ N, 167 22' 51.90″ E in the Pacific Ocean, in July 2009. We performed a bathymetric survey, recorded salinity, dissolved oxygen, pH, and temperature profiles, monitored the tidal variability, and conducted a vegetation survey surrounding the lake. From bathymetric data we calculated the lake volume, which we used to estimate the lake's salt budget, and ultimately the residence time of water in the lake basin. We took a series of sediment cores from the lake, cores which indicate Lib Island's changing environment and climate. Radiocarbon measurements determined sediment age, and reveal significant mixing over the last 2 ka of deposition. We conclude that prior to 3 ka, Lib Island was an atoll with a central lagoon connected to the open ocean, which was then closed off from the open ocean to form the brackish system that exists today. We predict that the sediment accumulation in Lib Pond evident today will continue. As seawater is inhibited from exchanging with fresh water, Lib Pond will become a shallower lake with increasingly fresh water.

  20. Overview of applications of Laser-Induced Breakdown Spectroscopy (LIBS)

    International Nuclear Information System (INIS)

    Cremers, D.A.

    1987-01-01

    Laser-induced breakdown spectroscopy (LIBS) is a method of performing elemental analyses of solids, liquids, and gases using the microplasma produced by a focused laser pulse. Because the microplasma is formed by optical radiation, LIBS has some important advantages compared to conventional laboratory based analytical methods. Three applications are discussed which use the LIBS method. 6 refs., 8 figs., 2 tabs

  1. The analysis of transient noise of PCB P/G network based on PI/SI co-simulation

    Science.gov (United States)

    Haohang, Su

    2018-02-01

    With the frequency of the space camera become higher than before, the power noise of the imaging electronic system become the important factor. Much more power noise would disturb the transmissions signal, and even influence the image sharpness and system noise. "Target impedance method" is one of the traditional design method of P/G network (power and ground network), which is shorted of transient power noise analysis and often made "over design". In this paper, a new design method of P/G network is provided which simulated by PI/SI co-simulation. The transient power noise can be simulated and then applied in the design of noise reduction, thus effectively controlling the change of the noise in the P/G network. The method can efficiently control the number of adding decoupling capacitor, and is very efficient and feasible to keep the power integrity.

  2. LiB and its boron-deficient variants under pressure

    KAUST Repository

    Hermann, Andreas

    2012-10-15

    Results of computational investigations of the structural and electronic properties of the ground states of binary compounds LiB x with 0.67 ≤x≤1.00 under pressure are reported. Structure predictions based on evolutionary algorithms and particle swarm optimization reveal that with increasing pressure, stoichiometric 1:1-LiB undergoes a variety of phase transitions, is significantly stabilized with respect to the elements and takes up a diamondoid boron network at high pressures. The Zintl picture is very useful in understanding the evolution of structures with pressure. The experimentally seen finite range of stability for LiB x phases with 0.8≤x≤1.00 is modeled both by boron-deficient variants of the 1:1-LiB structure and lithium-enriched intercalation structures. We find that the finite stability range vanishes at pressures P≥40GPa, where stoichiometric compounds then become more stable. A metal-to-insulator transition for LiB is predicted at P = 70 GPa. © 2012 American Physical Society.

  3. LiB and its boron-deficient variants under pressure

    KAUST Repository

    Hermann, Andreas; Suarez-Alcubilla, Ainhoa; Gurtubay, Idoia G.; Yang, Li-Ming; Bergara, Aitor; Ashcroft, N. W.; Hoffmann, Roald

    2012-01-01

    Results of computational investigations of the structural and electronic properties of the ground states of binary compounds LiB x with 0.67 ≤x≤1.00 under pressure are reported. Structure predictions based on evolutionary algorithms and particle swarm optimization reveal that with increasing pressure, stoichiometric 1:1-LiB undergoes a variety of phase transitions, is significantly stabilized with respect to the elements and takes up a diamondoid boron network at high pressures. The Zintl picture is very useful in understanding the evolution of structures with pressure. The experimentally seen finite range of stability for LiB x phases with 0.8≤x≤1.00 is modeled both by boron-deficient variants of the 1:1-LiB structure and lithium-enriched intercalation structures. We find that the finite stability range vanishes at pressures P≥40GPa, where stoichiometric compounds then become more stable. A metal-to-insulator transition for LiB is predicted at P = 70 GPa. © 2012 American Physical Society.

  4. Characterization of organic materials by LIBS for exploration of correlation between molecular and elemental LIBS signals

    Directory of Open Access Journals (Sweden)

    Shikha Rai

    2011-12-01

    Full Text Available The present study is performed for the preparation of a database by accumulating LIBS spectra of 4-nitroaniline and 4-nitrotoluene in air and argon. Changes in the behavior of the molecular bands of the C2 Swan system and CN violet system as well as of atomic lines of C, H and N in the LIBS signal are appreciable in argon. In order to explore the correlation between observed LIBS signal and molecular composition of these materials, normalized intensities of the emission lines have been estimated for each compound. It has been found that the relative rates of increase/decrease in the normalized intensities for all sets are higher for 4-nitrotoluene in argon. The cause of the higher rate for 4-nitrotoluene might be due to the possession of a distinctive functional group. The ultimate goal behind the whole study is to use this data-base as input for the discrimination of energetic materials.

  5. Study of different concentric rings inside gallstones with LIBS.

    Science.gov (United States)

    Pathak, Ashok Kumar; Singh, Vivek Kumar; Rai, Nilesh Kumar; Rai, Awadhesh Kumar; Rai, Pradeep Kumar; Rai, Pramod Kumar; Rai, Suman; Baruah, G D

    2011-07-01

    Gallstones obtained from patients from the north-east region of India (Assam) were studied using laser-induced breakdown spectroscopy (LIBS) technique. LIBS spectra of the different layers (in cross-section) of the gallstones were recorded in the spectral region 200-900 nm. Several elements, including calcium, magnesium, manganese, copper, silicon, phosphorus, iron, sodium and potassium, were detected in the gallstones. Lighter elements, including carbon, hydrogen, nitrogen and oxygen were also detected, which demonstrates the superiority of the LIBS technique over other existing analytical techniques. The LIBS technique was applied to investigate the evolution of C(2) swan bands and CN violet bands in the LIBS spectra of the gallstones in air and an argon atmosphere. The different layers (dark and light layers) of the gallstones were discriminated on the basis of the presence and intensities of the spectral lines for carbon, hydrogen, nitrogen, oxygen and copper. An attempt was also made to correlate the presence of major and minor elements in the gallstones with the common diet of the population of Assam.

  6. Identification of Polymers by Means of LIBS

    Science.gov (United States)

    Anzano, Jesús M.; Bello-Gálvez, Cristina; Lasheras, Roberto J.

    Laser-induced breakdown spectroscopy (LIBS) is mainly an elemental analysis technique which is applied several fields. However, molecular materials are almost entirely atomized when exposed to intense laser radiation sufficient for breakdown. This limitation has been solved by researchers using statistical tools as chemometric techniques. In this chapter, the authors expose one review about the identification of polymeric materials using LIBS; and particularly, the different chemometric techniques.

  7. LIBS analysis of artificial calcified tissues matrices.

    Science.gov (United States)

    Kasem, M A; Gonzalez, J J; Russo, R E; Harith, M A

    2013-04-15

    In most laser-based analytical methods, the reproducibility of quantitative measurements strongly depends on maintaining uniform and stable experimental conditions. For LIBS analysis this means that for accurate estimation of elemental concentration, using the calibration curves obtained from reference samples, the plasma parameters have to be kept as constant as possible. In addition, calcified tissues such as bone are normally less "tough" in their texture than many samples, especially metals. Thus, the ablation process could change the sample morphological features rapidly, and result in poor reproducibility statistics. In the present work, three artificial reference sample sets have been fabricated. These samples represent three different calcium based matrices, CaCO3 matrix, bone ash matrix and Ca hydroxyapatite matrix. A comparative study of UV (266 nm) and IR (1064 nm) LIBS for these three sets of samples has been performed under similar experimental conditions for the two systems (laser energy, spot size, repetition rate, irradiance, etc.) to examine the wavelength effect. The analytical results demonstrated that UV-LIBS has improved reproducibility, precision, stable plasma conditions, better linear fitting, and the reduction of matrix effects. Bone ash could be used as a suitable standard reference material for calcified tissue calibration using LIBS with a 266 nm excitation wavelength. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Implementing LibGuides 2: An Academic Case Study

    Science.gov (United States)

    Duncan, Vicky; Lucky, Shannon; McLean, Jaclyn

    2015-01-01

    Since 1997, the University of Saskatchewan Library has used "subject pages" to highlight key library resources. When Springshare announced it was launching LibGuides v2, a project team was assembled to transition a mixture of locally produced guides and guides created with the original LibGuides v1 software. This article synthesizes best…

  9. Induction of resistance in chickpea (Cicer arietinum L. against Ascochyta rabiei by applying chemicals and plant extracts Inducción de resistencia en garbanzo (Cicer arietinum L. contra Ascochyta rabiei por la aplicación de productos químicos y extractos vegetales

    Directory of Open Access Journals (Sweden)

    M Usman Ghazanfar

    2011-03-01

    Full Text Available Since new fungicides are scarce in the market and because of environmental problems, researchers are now emphasizing other alternatives, such as the genetic potential of plants, resistance against pathogens, and the use of biotic and abiotic agents to develop induced or acquired resistance. We investigated the role of resistance-inducing substances (chemicals and plant extracts in three chickpea cvs. C-44, Pb-91, and Bittle-98 in field experiments against Ascochyta blight disease. These cultivars were selected on the basis of better yield potential shown in previous experiments. Aqueous solution of salicylic acid (SA at 0.5, 1.0, and 1.5 mM; acibenzolar-S-methyl (Bion®, ASM at 0.4, 0.8, and 1.2 mM; and KOH at 25, 50, and 75 mM were applied, whereas Azadirachta indica A. Juss., Datura metel L., and Allium sativum L. plant extracts were applied at 5, 10, and 15%. Disease reduction data was recorded at different intervals from 4 to 14 d after being induced and inoculated with the pathogen. Overall results revealed that significant disease reduction (79.3% was provided by ASM in the cv. C-44 at 1.2 mM compared with SA, whereas the least significant was KOH. Maximum disease reduction (43.5% against disease in the plant extracts was observed by applying A. indica leaf extract, but D. metel and A. sativum extracts were not effective. Our findings suggest that enhancing resistance before infecting chickpea plants could be an innovative control method for Ascochyta blight of chickpea.Debido a la escasez de nuevos fungicidas en el mercado y problemas ambientales, los investigadores están ahora enfatizando otras alternativas, tales como potencial genético de las plantas, resistencia contra patógenos y uso de agentes bióticos y abióticos para el desarrollo de resistencia inducida y adquirida. Investigamos el rol de sustancias inductoras de resistencia (químicos y extractos vegetales en tres cultivares de garbanzo ‘C-44’, ‘Pb-91’,

  10. Downhole Elemental Analysis with LIBS

    Science.gov (United States)

    Moreschini, Paolo; Zacny, Kris; Rickman, Doug

    2011-01-01

    In this paper we discuss a novel instrument, currently under development at Honeybee Robotics with SBIR funding from NASA. The device is designed to characterize elemental composition as a function of depth in non-terrestrial geological formations. The instrument consists of a miniaturized laser-induced breakdown spectrometer (LIBS) analyzer integrated in a 2" diameter drill string. While the drill provides subsurface access, the LIBS analyzer provides information on the elemental composition of the borehole wall. This instrument has a variety of space applications ranging from exploration of the Moon for which it was originally designed, to Mars, as well as a variety of terrestrial applications. Subsurface analysis is usually performed by sample acquisition through a drill or excavator, followed by sample preparation and subsequent sample presentation to an instrument or suite of instruments. An alternative approach consisting in bringing a miniaturized version of the instrument to the sample has many advantages over the traditional methodology, as it allows faster response, reduced probability of cross-contamination and a simplification in the sampling mechanisms. LIBS functions by focusing a high energy laser on a material inducing a plasma consisting of a small fraction of the material under analysis. Optical emission from the plasma, analyzed by a spectrometer, can be used to determine elemental composition. A triangulation sensor located in the sensor head determines the distance of the sensor from the borehole wall. An actuator modifies the position of the sensor accordingly, in order to compensate for changes due to the profile of the borehole walls. This is necessary because LIBS measurements are negatively affected by changes in the relative position of the focus of the laser with respect to the position of the sample (commonly referred to as the "lens to sample distance"). Profiling the borehole is done by adjusting the position of the sensor with a

  11. Rotating and propagating LIB stabilized by self-induced magnetic field

    International Nuclear Information System (INIS)

    Murakami, H.; Aoki, T.; Kawata, S.; Niu, K.

    1984-01-01

    Rotating motion of a propagating LIB is analyzed in order to suppress the mixed mode of the Kelvin-Helmholtz instability, the tearing instability and the sausage instability by the action of a self-induced magnetic field in the axial direction. The beams are assumed to be charge-neutralized but not current-neutralized. The steady-state solutions of a propagating LIB with rotation are first obtained numerically. Through the dispersion relation with respect to the ikonal type of perturbations, which are added to the steady-state solutions, the growth rates of instabilities appearing in an LIB are obtained. It is concluded that if the mean rotating velocity of an LIB is comparable to the propagation velocity, the instability disappears in the propagating ion beam. (author)

  12. AD-LIBS: inferring ancestry across hybrid genomes using low-coverage sequence data.

    Science.gov (United States)

    Schaefer, Nathan K; Shapiro, Beth; Green, Richard E

    2017-04-04

    Inferring the ancestry of each region of admixed individuals' genomes is useful in studies ranging from disease gene mapping to speciation genetics. Current methods require high-coverage genotype data and phased reference panels, and are therefore inappropriate for many data sets. We present a software application, AD-LIBS, that uses a hidden Markov model to infer ancestry across hybrid genomes without requiring variant calling or phasing. This approach is useful for non-model organisms and in cases of low-coverage data, such as ancient DNA. We demonstrate the utility of AD-LIBS with synthetic data. We then use AD-LIBS to infer ancestry in two published data sets: European human genomes with Neanderthal ancestry and brown bear genomes with polar bear ancestry. AD-LIBS correctly infers 87-91% of ancestry in simulations and produces ancestry maps that agree with published results and global ancestry estimates in humans. In brown bears, we find more polar bear ancestry than has been published previously, using both AD-LIBS and an existing software application for local ancestry inference, HAPMIX. We validate AD-LIBS polar bear ancestry maps by recovering a geographic signal within bears that mirrors what is seen in SNP data. Finally, we demonstrate that AD-LIBS is more effective than HAPMIX at inferring ancestry when preexisting phased reference data are unavailable and genomes are sequenced to low coverage. AD-LIBS is an effective tool for ancestry inference that can be used even when few individuals are available for comparison or when genomes are sequenced to low coverage. AD-LIBS is therefore likely to be useful in studies of non-model or ancient organisms that lack large amounts of genomic DNA. AD-LIBS can therefore expand the range of studies in which admixture mapping is a viable tool.

  13. Evaluation of chickpea genotypes for resistance to Ascochyta blight (Ascochyta rabiei disease in the dry highlands of Kenya

    Directory of Open Access Journals (Sweden)

    Paul K. KIMURTO

    2013-05-01

    Full Text Available Chickpea (Cicer arietinum is an edible legume grown widely for its nutritious seed, which is rich in protein, minerals, vitamins and dietary fibre. It’s a new crop in Kenya whose potential has not been utilized fully due to abiotic and biotic stresses that limit its productivity. The crop is affected mainly by Ascochyta blight (AB which is widespread in cool dry highlands causing up to 100% yield loss. The objective of this study was to evalu- ate the resistance of selected chickpea genotypes to AB in dry highlands of Kenya. The study was done in 2 sites (Egerton University-Njoro and Agricultural Training centre-ATC-Koibatek for one season during long rains of 2010/2011 growing season. Thirty six genotypes from reference sets and mini-core samples introduced from ICR- SAT were evaluated. There were significant (P<0.001 differences in AB responses and grain yield performance in test genotypes in both sites. AB was more severe at Egerton-Njoro (mean score 5.7 than ATC-Koibatek (mean score 4.25, with subsequent low grain yield. Genotypes ICC7052, ICC4463, ICC4363, ICC2884, ICC7150, ICC15294 and ICC11627 had both highest grain yield in decreasing order (mean range 1790-1053 Kg ha-1 and best resist- ance to AB. Further evaluation is needed in other multi-locations and their use in breeding program determined especially because of their undesirable black seed color. Commercial varieties (LDT068, LDT065, Chania desi 1, and Saina K1 were all susceptible to AB, but with grain yield >1200 Kg ha-1. The findings of the study showed that chickpea should be sown during the short rains (summer in the dry highlands of Kenya when conditions are drier and warmer and less favorable for AB infection. However yield could be increased by shifting the sowing date from dry season to long rain (winter thus avoiding terminal drought if AB resistant cultivars with acceptable agronomic traits could be identified.

  14. Elemental misinterpretation in automated analysis of LIBS spectra.

    Science.gov (United States)

    Hübert, Waldemar; Ankerhold, Georg

    2011-07-01

    In this work, the Stark effect is shown to be mainly responsible for wrong elemental allocation by automated laser-induced breakdown spectroscopy (LIBS) software solutions. Due to broadening and shift of an elemental emission line affected by the Stark effect, its measured spectral position might interfere with the line position of several other elements. The micro-plasma is generated by focusing a frequency-doubled 200 mJ pulsed Nd/YAG laser on an aluminum target and furthermore on a brass sample in air at atmospheric pressure. After laser pulse excitation, we have measured the temporal evolution of the Al(II) ion line at 281.6 nm (4s(1)S-3p(1)P) during the decay of the laser-induced plasma. Depending on laser pulse power, the center of the measured line is red-shifted by 130 pm (490 GHz) with respect to the exact line position. In this case, the well-known spectral line positions of two moderate and strong lines of other elements coincide with the actual shifted position of the Al(II) line. Consequently, a time-resolving software analysis can lead to an elemental misinterpretation. To avoid a wrong interpretation of LIBS spectra in automated analysis software for a given LIBS system, we recommend using larger gate delays incorporating Stark broadening parameters and using a range of tolerance, which is non-symmetric around the measured line center. These suggestions may help to improve time-resolving LIBS software promising a smaller probability of wrong elemental identification and making LIBS more attractive for industrial applications.

  15. OML for the Libs+ system using PFW

    CERN Document Server

    Hahn, J A

    1999-01-01

    Passport for Windows (PFW) is not limited to accessing OCLC's systems. It can also access a local Libs+ system through the Internet. Such a connection makes it possible to use the automation capabilities of the OCLC Macro Language (OML), which is built into PFW, for the local Libs+ system. Once certain setup requirements have been completed, PFW can be used to quickly accomplish many routine tasks and thereby increase productivity and decrease error rates. Because it can be used to automate many local tasks, PFW remains an important tool for librarians. (0 refs).

  16. Laser induced breakdown spectroscopy (LIBS) as a rapid tool for material analysis

    International Nuclear Information System (INIS)

    Hussain, T; Gondal, M A

    2013-01-01

    Laser induced breakdown spectroscopy (LIBS) is a novel technique for elemental analysis based on laser-generated plasma. In this technique, laser pulses are applied for ablation of the sample, resulting in the vaporization and ionization of sample in hot plasma which is finally analyzed by the spectrometer. The elements are identified by their unique spectral signatures. LIBS system was developed for elemental analysis of solid and liquid samples. The developed system was applied for qualitative as well as quantitative measurement of elemental concentration present in iron slag and open pit ore samples. The plasma was generated by focusing a pulsed Nd:YAG laser at 1064 nm on test samples to study the capabilities of LIBS as a rapid tool for material analysis. The concentrations of various elements of environmental significance such as cadmium, calcium, magnesium, chromium, manganese, titanium, barium, phosphorus, copper, iron, zinc etc., in these samples were determined. Optimal experimental conditions were evaluated for improving the sensitivity of developed LIBS system through parametric dependence study. The laser-induced breakdown spectroscopy (LIBS) results were compared with the results obtained using standard analytical technique such as inductively couple plasma emission spectroscopy (ICP). Limit of detection (LOD) of our LIBS system were also estimated for the above mentioned elements. This study demonstrates that LIBS could be highly appropriate for rapid online analysis of iron slag and open pit waste.

  17. Laser induced breakdown spectroscopy (LIBS) as a rapid tool for material analysis

    Science.gov (United States)

    Hussain, T.; Gondal, M. A.

    2013-06-01

    Laser induced breakdown spectroscopy (LIBS) is a novel technique for elemental analysis based on laser-generated plasma. In this technique, laser pulses are applied for ablation of the sample, resulting in the vaporization and ionization of sample in hot plasma which is finally analyzed by the spectrometer. The elements are identified by their unique spectral signatures. LIBS system was developed for elemental analysis of solid and liquid samples. The developed system was applied for qualitative as well as quantitative measurement of elemental concentration present in iron slag and open pit ore samples. The plasma was generated by focusing a pulsed Nd:YAG laser at 1064 nm on test samples to study the capabilities of LIBS as a rapid tool for material analysis. The concentrations of various elements of environmental significance such as cadmium, calcium, magnesium, chromium, manganese, titanium, barium, phosphorus, copper, iron, zinc etc., in these samples were determined. Optimal experimental conditions were evaluated for improving the sensitivity of developed LIBS system through parametric dependence study. The laser-induced breakdown spectroscopy (LIBS) results were compared with the results obtained using standard analytical technique such as inductively couple plasma emission spectroscopy (ICP). Limit of detection (LOD) of our LIBS system were also estimated for the above mentioned elements. This study demonstrates that LIBS could be highly appropriate for rapid online analysis of iron slag and open pit waste.

  18. [Quantitative analysis of Cu in water by collinear DP-LIBS].

    Science.gov (United States)

    Zheng, Mei-Lan; Yao, Ming-Yin; Chen, Tian-Bing; Lin, Yong-Zeng; Li, Wen-Bing; Liu, Mu-Hua

    2014-07-01

    The purpose of this research is to study the influence of double pulse laser induced breakdown spectroscopy (DP-LIBS) on the sensitivity of Cu in water. The water solution of Cu was tested by collinear DP-LIBS in this article. The results show that spectral intensity of Cu can be enhanced obviously by DP-LIBS, compared with single pulse laser induced breakdown spectroscopy (SP-LIBS). Besides, the experimental results were significantly impacted by delay time between laser pulse and spectrometer acquisition, delay time of double laser pulse and energy of laser pulse and so on. The paper determined the best conditions for DP-LIBS detecting Cu in water. The optimal acquisition delay time was 1 380 ns. The best laser pulse delay time was 25 ns. The most appropriate energy of double laser pulse was 100 mJ. Characteristic analysis of spectra of Cu at 324.7 and 327.4 nm was done for quantitative analysis. The detection limit was 3.5 microg x mL(-1) at 324.7 nm, and the detection limit was 4.84 microg x mL(-1) at 327.4 nm. The relative standard deviation of the two characteristic spectral lines was within 10%. The calibration curve of characteristic spectral line, established by 327.4 nm, was verified with 500 microg x mL(-1) sample. Concentration of the sample was 446 microg x mL(-1) calculated by the calibration curve. This research shows that the detection sensitivity of Cu in water can be improved by DP-LIBS. At the same time, it had high stability.

  19. Study of archaeological coins of different dynasties using libs coupled with multivariate analysis

    Science.gov (United States)

    Awasthi, Shikha; Kumar, Rohit; Rai, G. K.; Rai, A. K.

    2016-04-01

    Laser Induced Breakdown Spectroscopy (LIBS) is an atomic emission spectroscopic technique having unique capability of an in-situ monitoring tool for detection and quantification of elements present in different artifacts. Archaeological coins collected form G.R. Sharma Memorial Museum; University of Allahabad, India has been analyzed using LIBS technique. These coins were obtained from excavation of Kausambi, Uttar Pradesh, India. LIBS system assembled in the laboratory (laser Nd:YAG 532 nm, 4 ns pulse width FWHM with Ocean Optics LIBS 2000+ spectrometer) is employed for spectral acquisition. The spectral lines of Ag, Cu, Ca, Sn, Si, Fe and Mg are identified in the LIBS spectra of different coins. LIBS along with Multivariate Analysis play an effective role for classification and contribution of spectral lines in different coins. The discrimination between five coins with Archaeological interest has been carried out using Principal Component Analysis (PCA). The results show the potential relevancy of the methodology used in the elemental identification and classification of artifacts with high accuracy and robustness.

  20. [Comparative investigation of underwater-LIBS using 532 and 1 064 nm lasers].

    Science.gov (United States)

    Song, Jiao-Jian; Tian, Ye; Lu, Yuan; Li, Ying; Zheng, Rong-Er

    2014-11-01

    With the hope of applying laser induced breakdown spectroscopy (LIBS) to the ocean applications, the laser energy at 532 and 1 064 nm wavelength with 3 and 40 mj respectively was used, which was near their breakdown threshold. Extensive experimental investigations of LIBS from CaCl2 water solution were carried out in this paper using different laser wavelengths of 532 and 1 064 nm. The obtained results show that compared with the 532 nm laser, the 1 064 nm laser can induce the plasma in water with higher emission intensity and longer lifetime, while the reproducibility of LIBS signal under 1 064 nm laser is poorer. On the other hand, due to the different attenuation ratios of 532 and 1 064 nm laser energies in water, the LIBS signal of 1 064 nm laser decreases a lot within the transmission distance range 2-5 cm, while LIBS signal of 532 nm remains the same, because that the wavelength of 532 nm lies in the "transmission window" of the water solution. This study will provide valuable design considerations for the development of LIBS-sea system in near future.

  1. Development and application of sequence-tagged microsatellite site (STMS) markers in chickpea (Cicer arietinum), banana (Musa spp.) and their major pathogens, Ascochyta rabiei and Mycosphaerella fijiensis

    International Nuclear Information System (INIS)

    Winter, P.; Kaemmer, D.; Paff, T.; Geistlinger, J.; Neu, C.; Kahl, G.

    2001-01-01

    DNA markers of various kinds have found widespread application in many facets of plant breeding and plant pathogen control. Yet another marker type, sequence-tagged microsatellite (STMS) markers, provides the markers of choice for nearly every crop because of their co-dominant nature, reliability, ease of application and high polymorphic information content. We report here on the development of a whole set of STMS markers and the respective, selected primer sequences for two important crops, chickpea (Cicer arietinum L.) and banana (Musa acuminata), and for their most devastating fungal pathogens, Ascochyta rabiei and Mycosphaerella fijiensis, respectively. These markers were generated either by direct screening of size-selected genomic libraries with microsatellite-complementary oligonucleotides, or by enrichment of DNA fragments containing microsatellite sequences. A total of 69 markers for chickpea, 15 markers for M. acuminata, 19 markers for A rabiei and 11 markers for M. fijiensis, selected on the basis of their high information content and ease of use are presented here. These can be applied for mapping of the respective genomes, for various population studies, and cultivar and isolate identification. We further demonstrate that several of these markers can potentially be applied across species boundaries and thus could increase the marker repertoire also for other species of the genus Cicer, Musa and for Ascochyta-type pathogens of bean, and potentially also of lentil and pea. (author)

  2. SeqLib: a C ++ API for rapid BAM manipulation, sequence alignment and sequence assembly.

    Science.gov (United States)

    Wala, Jeremiah; Beroukhim, Rameen

    2017-03-01

    We present SeqLib, a C ++ API and command line tool that provides a rapid and user-friendly interface to BAM/SAM/CRAM files, global sequence alignment operations and sequence assembly. Four C libraries perform core operations in SeqLib: HTSlib for BAM access, BWA-MEM and BLAT for sequence alignment and Fermi for error correction and sequence assembly. Benchmarking indicates that SeqLib has lower CPU and memory requirements than leading C ++ sequence analysis APIs. We demonstrate an example of how minimal SeqLib code can extract, error-correct and assemble reads from a CRAM file and then align with BWA-MEM. SeqLib also provides additional capabilities, including chromosome-aware interval queries and read plotting. Command line tools are available for performing integrated error correction, micro-assemblies and alignment. SeqLib is available on Linux and OSX for the C ++98 standard and later at github.com/walaj/SeqLib. SeqLib is released under the Apache2 license. Additional capabilities for BLAT alignment are available under the BLAT license. jwala@broadinstitue.org ; rameen@broadinstitute.org. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  3. Long-wave, infrared laser-induced breakdown (LIBS) spectroscopy emissions from energetic materials.

    Science.gov (United States)

    Yang, Clayton S-C; Brown, Ei E; Hommerich, Uwe; Jin, Feng; Trivedi, Sudhir B; Samuels, Alan C; Snyder, A Peter

    2012-12-01

    Laser-induced breakdown spectroscopy (LIBS) has shown great promise for applications in chemical, biological, and explosives sensing and has significant potential for real-time standoff detection and analysis. In this study, LIBS emissions were obtained in the mid-infrared (MIR) and long-wave infrared (LWIR) spectral regions for potential applications in explosive material sensing. The IR spectroscopy region revealed vibrational and rotational signatures of functional groups in molecules and fragments thereof. The silicon-based detector for conventional ultraviolet-visible LIBS operations was replaced with a mercury-cadmium-telluride detector for MIR-LWIR spectral detection. The IR spectral signature region between 4 and 12 μm was mined for the appearance of MIR and LWIR-LIBS emissions directly indicative of oxygenated breakdown products as well as dissociated, and/or recombined sample molecular fragments. Distinct LWIR-LIBS emission signatures from dissociated-recombination sample molecular fragments between 4 and 12 μm are observed for the first time.

  4. LIBS coupled with ICP/OES for the spectral analysis of betel leaves

    Science.gov (United States)

    Rehan, I.; Rehan, K.; Sultana, S.; Khan, M. Z.; Muhammad, R.

    2018-05-01

    Laser-induced breakdown spectroscopy (LIBS) system was optimized and was applied for the elemental analysis and exposure of the heavy metals in betel leaves in air. Pulsed Nd:YAG (1064 nm) in conjunction with a suitable detector (LIBS 2000+, Ocean Optics, Inc) having the optical resolution of 0.06 nm was used to record the emission spectra from 200 to 720 nm. Elements like Al, Ba, Ca, Cr, Cu, P, Fe, K, Mg, Mn, Na, P, S, Sr, and Zn were found to be present in the samples. The abundances of observed elements were calculated through normalized calibration curve method, integrated intensity ratio method, and calibration free-LIBS approach. Quantitative analyses were accomplished under the assumption of local thermodynamic equilibrium (LTE) and optically thin plasma. LIBS findings were validated by comparing its results with the results obtained using a typical analytical technique of inductively coupled plasma-optical emission spectroscopy (ICP/OES). Limit of detection (LOD) of the LIBS system was also estimated for heavy metals.

  5. LIBS Sensor for Sub-surface CO2 Leak Detection in Carbon Sequestration

    Directory of Open Access Journals (Sweden)

    Jinesh JAIN

    2017-07-01

    Full Text Available Monitoring carbon sequestration poses numerous challenges to the sensor community. For example, the subsurface environment is notoriously harsh, with large potential mechanical, thermal, and chemical stresses, making long-term stability and survival a challenge to any potential in situ monitoring method. Laser induced breakdown spectroscopy (LIBS has been demonstrated as a promising technology for chemical monitoring of harsh environments and hard to reach places. LIBS has a real- time monitoring capability and can be used for the elemental and isotopic analysis of solid, liquid, and gas samples. The flexibility of the probe design and the use of fiber- optics has made LIBS particularly suited for remote measurements. The paper focuses on developing a LIBS instrument for downhole high-pressure, high-temperature brine experiments, where CO2 leakage could result in changes in the trace mineral composition of an aquifer. The progress in fabricating a compact, robust, and simple LIBS sensor for widespread subsurface leak detection is presented.

  6. SNP-based linkage mapping for validation of QTLs for resistance to ascochyta blight in lentil

    Directory of Open Access Journals (Sweden)

    Shimna Sudheesh

    2016-11-01

    Full Text Available Lentil (Lens culinaris Medik. is a self-pollinating, diploid, annual, cool-season, food legume crop that is cultivated throughout the world. Ascochyta blight (AB, caused by Ascochyta lentis Vassilievsky, is an economically important and widespread disease of lentil. Development of cultivars with high levels of durable resistance provides an environmentally acceptable and economically feasible method for AB control. A detailed understanding of the genetic basis of AB resistance is hence highly desirable, in order to obtain insight into the number and influence of resistance genes. Genetic linkage maps based on single nucleotide polymorphisms (SNP and simple sequence repeat (SSR markers have been developed from three recombinant inbred line (RIL populations. The IH x NF map contained 460 loci across 1461.6 cM, while the IH x DIG map contained 329 loci across 1302.5 cM and the third map, NF x DIG contained 330 loci across 1914.1 cM. Data from these maps were combined with a map from a previously published study through use of bridging markers to generate a consensus linkage map containing 689 loci distributed across 7 linkage groups (LGs, with a cumulative length of 2429.61 cM at an average density of one marker per 3.5 cM. Trait dissection of AB resistance was performed for the RIL populations, identifying totals of two and three quantitative trait loci (QTLs explaining 52% and 69% of phenotypic variation for resistance to infection in the IH x DIG and IH x NF populations, respectively. Presence of common markers in the vicinity of the AB_IH1- and AB_IH2.1/AB_IH2.2-containing regions on both maps supports the inference that a common genomic region is responsible for conferring resistance and is associated with the resistant parent, Indianhead. The third QTL was derived from Northfield. Evaluation of markers associated with AB resistance across a diverse lentil germplasm panel revealed that the identity of alleles associated with AB_IH1 predicted

  7. ImgLib2--generic image processing in Java.

    Science.gov (United States)

    Pietzsch, Tobias; Preibisch, Stephan; Tomancák, Pavel; Saalfeld, Stephan

    2012-11-15

    ImgLib2 is an open-source Java library for n-dimensional data representation and manipulation with focus on image processing. It aims at minimizing code duplication by cleanly separating pixel-algebra, data access and data representation in memory. Algorithms can be implemented for classes of pixel types and generic access patterns by which they become independent of the specific dimensionality, pixel type and data representation. ImgLib2 illustrates that an elegant high-level programming interface can be achieved without sacrificing performance. It provides efficient implementations of common data types, storage layouts and algorithms. It is the data model underlying ImageJ2, the KNIME Image Processing toolbox and an increasing number of Fiji-Plugins. ImgLib2 is licensed under BSD. Documentation and source code are available at http://imglib2.net and in a public repository at https://github.com/imagej/imglib. Supplementary data are available at Bioinformatics Online. saalfeld@mpi-cbg.de

  8. Wavelength dependence of laser induced breakdown spectroscopy (LIBS) on questioned document investigation.

    Science.gov (United States)

    Elsherbiny, Nany; Aied Nassef, O

    2015-07-01

    The fast and nearly non-destructive criteria of laser induced breakdown spectroscopy (LIBS) technique has been exploited for forensic purposes, specifically, document investigation. The dependence of the optical emission spectra of different black gel ink samples on the excitation laser wavelength, namely the visible wavelength at λ=532 nm and the IR wavelength at λ=1064 nm, was studied. The inks of thirty black gel-ink pens comprising ten brands were analyzed to determine the variation of the chemical composition of ink and to discriminate among them with minimum mass removal and minimum damage to the document's paper. Under the adopted experimental conditions, the ability of the visible LIBS to differentiate among the different ink samples was successful compared to IR LIBS at the same laser pulse energy (~25 mJ/pulse, laser fluence is ~1400J·cm(-2) for visible laser and ~1100J·cm(-2) for IR laser) which could be attributed to the IR absorption effects by the black ink. However, the visible LIBS produces deeper crater with respect to that produced by IR LIBS. Applying IR LIBS with higher pulse energy of ~87mJ (laser fluence is ~4100J·cm(-2)), identification and differentiation of the adopted samples was performed with producing a larger-diameter but superficial crater. The plasma parameters are discussed at the adopted experimental conditions. The results support the potential of LIBS technique using both the visible and IR lasers to be commercially developed for forensic document examination. Copyright © 2015 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  9. Identification and sorting of materials with portable LIBS before decommissioning

    International Nuclear Information System (INIS)

    Vors, Evelyne; Sirven, Jean-Baptiste; Dehayem-Massop, Alix; Gallou, Guillaume

    2016-01-01

    Laser Induced Breakdown Spectroscopy (LIBS) is a technique of elemental analysis. A laser beam is focused on the surface of the sample to be analyzed. A small quantity of matter is ablated and a plasma formed by the atomized compounds is created. The spectral lines of the light emitted by the plasma are detected by an optical spectrometer. LIBS is a fully optical, multi-elementary and fast analytical technique, requiring no or little sample preparation. These features make the LIBS technique particularly suited for in situ measurements, and portable instruments are currently developed. LIBS analysis can be applied to the identification of materials using chemometric statistical methods (multivariate analysis) connecting the spectrum to the nature of the sample. Such methods have been successfully applied in our laboratory to the determination of the geographical origin of yellow cakes and to the identification of alloys. We present here the work performed with a portable LIBS instrument to meet the needs of waste sorting in industrial domain and in nuclear domain (inventory before decommissioning). A data base of LIBS spectra was built with a commercial instrument (IVEA SAS Easylibs) with samples of four categories of interest for industrial waste sorting: alloys, plastics, concrete and glasses. Different correct identification rates are requested by categories. The alloy spectra contain characteristic spectral lines and sub-categories can be easily discriminated (for example, different steel classes can be identified). The components of the plastics (mainly C, H, O and N) give rise to less characteristic lines and the plastics identification requires a separate study. Supervised statistical models are built with the data base spectra and predictions are instantly calculated for the spectra of unknown materials to identify in order to direct them to the correct waste stream. (authors)

  10. [Rapid measurement of trace mercury in aqueous solutions with optical-electrical dual pulse LIBS technique].

    Science.gov (United States)

    Zhang, Qian; Xiong, Wei; Chen, Yu-Qi; Li, Run-Hua

    2011-02-01

    A wood slice was used as absorber to transfer liquid sample to solid sample in order to solve the problems existing in directly analyzing aqueous solutions with laser-induced breakdown spectroscopy (LIBS). An optical-electrical dual pulse LIBS (OEDP-LIBS) technique was first used to enhance atomic emission of mercury in laser-induced plasma. The calibration curves of mercury were obtained by typical single pulse LIBS and OEDP-LIBS techniques. The limit of detection (LOD) of mercury in these two techniques reaches 2.4 and 0.3 mg x L(-1), respectively. Under current experimental conditions, the time-integrated a tomic emission of mercury at 253.65 nm was enhanced 50 times and the LOD of mercury was improved by one order, if comparing OEDP-LIBS to single pulse LIBS. The required time for a whole analysis process is less than 5 minutes. As the atomic emission of mercury decays slowly while increasing the delay time between electrical pulse and laser pulse, increasing the electrical pulse width can further enhance the time integrated intensity of mercury emission and improve the detection sensitivity of mercury by OEDP-LIBS technique.

  11. Laser induced spectroscopy breakdown (LIBS) application to heavy metal detection in soils

    International Nuclear Information System (INIS)

    Barbini, R.; Fantoni, R.; Palucci, A.; Ribezzo, S.; Colao, F.; Capitelli, F.

    2000-01-01

    LIBS (Laser induced breakdown spectroscopy) is a new spectroscopic technique suitable to the use in the analysis of samples of environmental interest, such as soils and rocks, and of industrial interest, such as alloys. Results dealing with the application of the technique to heterogeneous soil samples certified by Ispra Joint Research Centre in the contest of heavy metals (Cd, Cr, Cu, Fe, Mn, Ni, Pb, Zn) with an agronomical interest are presented in this report. In the LIBS technique, a high power laser beam is focused onto the sample in order to generate a small volume of plasma at its surface. Emissions from single atomic species are collected by a lens system coupled to an optical fiber bundle, dispersed on a monochromator and analyzed by an iCCD. the identification and the assignment of emission lines relevant to single atomic species allows to determine the sample elemental composition and, after calibration against reference samples, to perform quantitative analysis for a large number of species. This technique requires no sample pre-treatment, a part from eventually compacting powders by mechanical press. This is a considerable advantage with respect to traditional spectroscopic techniques, such as the ICP (Inductively Coupled Plasma) which needs sample mineralization by acid attack. Measurements performed on soil samples by means of the LIBS technique at ENEA Frascati were compared with the results obtained by ICP, which is considered a traditional technique for this kind of analysis. Results showed a general overestimation of the LIBS values with respect to the ICP ones, probably due to differences in lytologic matrix between the analyzed samples and the standard. The phenomenon is usually referred to the matrix effect, which is held responsible for the deviation from linearity between single element concentration and its row intensity. The effect is due to local plasma density variations and limit the correlation between the plasma elemental composition

  12. LibKiSAO: a Java library for Querying KiSAO.

    Science.gov (United States)

    Zhukova, Anna; Adams, Richard; Laibe, Camille; Le Novère, Nicolas

    2012-09-24

    The Kinetic Simulation Algorithm Ontology (KiSAO) supplies information about existing algorithms available for the simulation of Systems Biology models, their characteristics, parameters and inter-relationships. KiSAO enables the unambiguous identification of algorithms from simulation descriptions. Information about analogous methods having similar characteristics and about algorithm parameters incorporated into KiSAO is desirable for simulation tools. To retrieve this information programmatically an application programming interface (API) for KiSAO is needed. We developed libKiSAO, a Java library to enable querying of the KiSA Ontology. It implements methods to retrieve information about simulation algorithms stored in KiSAO, their characteristics and parameters, and methods to query the algorithm hierarchy and search for similar algorithms providing comparable results for the same simulation set-up. Using libKiSAO, simulation tools can make logical inferences based on this knowledge and choose the most appropriate algorithm to perform a simulation. LibKiSAO also enables simulation tools to handle a wider range of simulation descriptions by determining which of the available methods are similar and can be used instead of the one indicated in the simulation description if that one is not implemented. LibKiSAO enables Java applications to easily access information about simulation algorithms, their characteristics and parameters stored in the OWL-encoded Kinetic Simulation Algorithm Ontology. LibKiSAO can be used by simulation description editors and simulation tools to improve reproducibility of computational simulation tasks and facilitate model re-use.

  13. libRoadRunner: a high performance SBML simulation and analysis library.

    Science.gov (United States)

    Somogyi, Endre T; Bouteiller, Jean-Marie; Glazier, James A; König, Matthias; Medley, J Kyle; Swat, Maciej H; Sauro, Herbert M

    2015-10-15

    This article presents libRoadRunner, an extensible, high-performance, cross-platform, open-source software library for the simulation and analysis of models expressed using Systems Biology Markup Language (SBML). SBML is the most widely used standard for representing dynamic networks, especially biochemical networks. libRoadRunner is fast enough to support large-scale problems such as tissue models, studies that require large numbers of repeated runs and interactive simulations. libRoadRunner is a self-contained library, able to run both as a component inside other tools via its C++ and C bindings, and interactively through its Python interface. Its Python Application Programming Interface (API) is similar to the APIs of MATLAB ( WWWMATHWORKSCOM: ) and SciPy ( HTTP//WWWSCIPYORG/: ), making it fast and easy to learn. libRoadRunner uses a custom Just-In-Time (JIT) compiler built on the widely used LLVM JIT compiler framework. It compiles SBML-specified models directly into native machine code for a variety of processors, making it appropriate for solving extremely large models or repeated runs. libRoadRunner is flexible, supporting the bulk of the SBML specification (except for delay and non-linear algebraic equations) including several SBML extensions (composition and distributions). It offers multiple deterministic and stochastic integrators, as well as tools for steady-state analysis, stability analysis and structural analysis of the stoichiometric matrix. libRoadRunner binary distributions are available for Mac OS X, Linux and Windows. The library is licensed under Apache License Version 2.0. libRoadRunner is also available for ARM-based computers such as the Raspberry Pi. http://www.libroadrunner.org provides online documentation, full build instructions, binaries and a git source repository. hsauro@u.washington.edu or somogyie@indiana.edu Supplementary data are available at Bioinformatics online. Published by Oxford University Press 2015. This work is written

  14. Laser induced spectroscopy breakdown (LIBS) application to heavy metal detection in soils; Applicazioni della tecnica Laser induced breakdown spectroscopy (LIBS) alla determinazione dei metalli pesanti nei suoli

    Energy Technology Data Exchange (ETDEWEB)

    Barbini, R.; Fantoni, R.; Palucci, A.; Ribezzo, S.; Colao, F. [ENEA, Centro Ricerche Frascati, Frascati, RM (Italy). Div. Fisica Applicata; Capitelli, F. [Bari, Univ., Bari (Italy). Dipt. di Biologia e Chimica Agroforestale ed Ambientale

    2000-07-01

    LIBS (Laser induced breakdown spectroscopy) is a new spectroscopic technique suitable to the use in the analysis of samples of environmental interest, such as soils and rocks, and of industrial interest, such as alloys. Results dealing with the application of the technique to heterogeneous soil samples certified by Ispra Joint Research Centre in the contest of heavy metals (Cd, Cr, Cu, Fe, Mn, Ni, Pb, Zn) with an agronomical interest are presented in this report. In the LIBS technique, a high power laser beam is focused onto the sample in order to generate a small volume of plasma at its surface. Emissions from single atomic species are collected by a lens system coupled to an optical fiber bundle, dispersed on a monochromator and analyzed by an iCCD. the identification and the assignment of emission lines relevant to single atomic species allows to determine the sample elemental composition and, after calibration against reference samples, to perform quantitative analysis for a large number of species. This technique requires no sample pre-treatment, a part from eventually compacting powders by mechanical press. This is a considerable advantage with respect to traditional spectroscopic techniques, such as the ICP (Inductively Coupled Plasma) which needs sample mineralization by acid attack. Measurements performed on soil samples by means of the LIBS technique at ENEA Frascati were compared with the results obtained by ICP, which is considered a traditional technique for this kind of analysis. Results showed a general overestimation of the LIBS values with respect to the ICP ones, probably due to differences in lytologic matrix between the analyzed samples and the standard. The phenomenon is usually referred to the matrix effect, which is held responsible for the deviation from linearity between single element concentration and its row intensity. The effect is due to local plasma density variations and limit the correlation between the plasma elemental composition

  15. Effective laser-induced breakdown spectroscopy (LIBS) detection using double pulse at optimum configuration.

    Science.gov (United States)

    Choi, Soo Jin; Yoh, Jack J

    2011-08-01

    A short laser pulse is irradiated on a sample to create a highly energetic plasma that emits light of a specific peak wavelength according to the material. By identifying different peaks for the analyzed samples, their chemical composition can be rapidly determined. The characteristics of the laser-induced breakdown spectroscopy (LIBS) plasma are strongly dependent on the ambient conditions. Research aimed at enhancing LIBS intensity is of great benefit in advancing LIBS for the exploration of harsh environments. By using double-pulse LIBS, the signal intensity of Al and Ca lines was enhanced by five times compared to the single-pulse signal. Also, the angles of the target and detector are adjusted to simulate samples of arbitrary shape. We verified that there exists an optimal angle at which specific elements of a test sample may be detected with stronger signal intensity. We provide several optimum configurations for the LIBS system for maximizing the signal intensity for the analysis of a nonstandard aluminum sample.

  16. Fast LIBS Identification of Aluminum Alloys

    Directory of Open Access Journals (Sweden)

    Tawfik W.

    2007-04-01

    Full Text Available Laser-induced breakdown spectroscopy (LIBS has been applied to analysis aluminum alloy targets. The plasma is generated by focusing a 300 mJ pulsed Nd: YAG laser on the target in air at atmospheric pressure. Such plasma emission spectrum was collected using a one-meter length wide band fused-silica optical fiber connected to a portable Echelle spectrometer with intensified CCD camera. Spectroscopic analysis of plasma evolution of laser produced plasmas has been characterized in terms of their spectra, electron density and electron temperature assuming the LTE and optically thin plasma conditions. The LIBS spectrum was optimized for high S/N ratio especially for trace elements. The electron temperature and density were determined using the emission intensity and stark broadening, respectively, of selected aluminum spectral lines. The values of these parameters were found to change with the aluminum alloy matrix, i.e. they could be used as a fingerprint character to distinguish between different aluminum alloy matrices using only one major element (aluminum without needing to analysis the rest of elements in the matrix. Moreover, It was found that the values of T(e and N(e decrease with increasing the trace elements concentrations in the aluminum alloy samples. The obtained results indicate that it is possible to improve the exploitation of LIBS in the remote on-line industrial monitoring application, by following up only the values of T(e and N(e for the aluminum in aluminum alloys using an optical fiber probe.

  17. Remote-LIBS characterization of ITER-like plasma facing materials

    International Nuclear Information System (INIS)

    Almaviva, S.; Caneve, L.; Colao, F.; Fantoni, R.; Maddaluno, G.

    2012-01-01

    Graphical abstract: Display Omitted Highlights: ► Description of a LIBS set-up as remote diagnostics in new generation fusion machines. ► Identification of the atomic composition of samples simulating plasma facing components. ► Submicrometric resolution in depth profiling the elemental composition of the samples. ► Identification of elements present in traces or as impurities on the sample surface. ► Discussion on the applicability of the Calibration Free method for quantitative analysis. - Abstract: The occurrence of several plasma-wall interaction processes, eventually affecting the overall system performances, is expected in a working fusion device chamber. Monitoring the changes in the composition of the plasma facing component (PFC) surface layer, as a result of erosion and redeposition mechanisms, can provide useful information on the possible plasma pollution and fuel retention. To this aim, suitable diagnostic techniques able to perform depth profiling analysis of the superficial layers on the PFCs have been developed. Due to the constraints commonly found in fusion devices, the measuring apparatus must be non invasive, remote and sensitive to light elements. These requirements make LIBS (Laser Induced Breakdown Spectroscopy) an ideal candidate for on-line monitoring the walls of current and of next generation (as ITER) fusion devices. LIBS is a well established tool for qualitative, semi-quantitative and quantitative analysis of surfaces, with micro-destructive characteristics and some capabilities for stratigraphy. In this work, LIBS depth profiling capability has been verified for the determination of the composition of multilayer structures simulating plasma facing components covered with deposited impurity layers. A new experimental setup has been designed and realized in order to optimize the characteristics of a LIBS system working in vacuum conditions and remotely, two noticeable properties for an ITER-relevant diagnostics. A quantitative

  18. Quantitative LIBS analysis of vanadium in samples of hexagonal mesoporous silica catalysts.

    Science.gov (United States)

    Pouzar, Miloslav; Kratochvíl, Tomás; Capek, Libor; Smoláková, Lucie; Cernohorský, Tomás; Krejcová, Anna; Hromádko, Ludek

    2011-02-15

    The method for the analysis of vanadium in hexagonal mesoporous silica (V-HMS) catalysts using Laser Induced Breakdown Spectrometry (LIBS) was suggested. Commercially available LIBS spectrometer was calibrated with the aid of authentic V-HMS samples previously analyzed by ICP OES after microwave digestion. Deposition of the sample on the surface of adhesive tape was adopted as a sample preparation method. Strong matrix effect connected with the catalyst preparation technique (1st vanadium added in the process of HMS synthesis, 2nd already synthesised silica matrix was impregnated by vanadium) was observed. The concentration range of V in the set of nine calibration standards was 1.3-4.5% (w/w). Limit of detection was 0.13% (w/w) and it was calculated as a triple standard deviation from five replicated determinations of vanadium in the real sample with a very low vanadium concentration. Comparable results of LIBS and ED XRF were obtained if the same set of standards was used for calibration of both methods and vanadium was measured in the same type of real samples. LIBS calibration constructed using V-HMS-impregnated samples failed for measuring of V-HMS-synthesized samples. LIBS measurements seem to be strongly influenced with different chemical forms of vanadium in impregnated and synthesised samples. The combination of LIBS and ED XRF is able to provide new information about measured samples (in our case for example about procedure of catalyst preparation). Copyright © 2010 Elsevier B.V. All rights reserved.

  19. Dicty_cDB: Contig-U03328-1 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available aria DNA, clone: DAB1-004E12.F.fa, ... 48 0.16 1 ( EC770709 ) EST 7205 Guarana fruits cDNA library Paul...... 44 2.4 1 ( EI726036 ) 2B421023C20TR BAC library from breast tumor sampl... 44...s sativus) mature stigma l... 44 2.4 1 ( EV118860 ) 0124172 Brassica napus Root lib...rary Brassica napu... 44 2.4 1 ( ES560299 ) B79 Ascochyta rabiei induced library Cicer arieti..... 50 0.040 1 ( BM027318 ) GIT0000656 Root-induced cDNA library from Glomus ... 50 0.040 1 ( BI505723 ) BB17

  20. Emission Characteristics of Laser-Induced Plasma Using Collinear Long and Short Dual-Pulse Laser-Induced Breakdown Spectroscopy (LIBS).

    Science.gov (United States)

    Wang, Zhenzhen; Deguchi, Yoshihiro; Liu, Renwei; Ikutomo, Akihiro; Zhang, Zhenzhen; Chong, Daotong; Yan, Junjie; Liu, Jiping; Shiou, Fang-Jung

    2017-09-01

    Collinear long and short dual-pulse laser-induced breakdown spectroscopy (DP-LIBS) was employed to clarify the emission characteristics from laser-induced plasma. The plasma was sustained and became stable by the long pulse-width laser with the pulse width of 60 μs under free running (FR) conditions as an external energy source. Comparing the measurement results of stainless steel in air using single-pulse LIBS (SP-LIBS) and DP-LIBS, the emission intensity was markedly enhanced using DP-LIBS. The temperature of plasma induced by DP-LIBS was maintained at a higher temperature under different gate delay time and short pulse-width laser power conditions compared with those measured using short SP-LIBS. Moreover, the variation rates of plasma temperatures measured using DP-LIBS were also lower. The superior detection ability was verified by the measurement of aluminum sample in water. The spectra were clearly detected using DP-LIBS, whereas it cannot be identified using SP-LIBS of short and long pulse widths. The effects of gate delay time and short pulse-width laser power were also discussed. These results demonstrate the feasibility and enhanced detection ability of the proposed collinear long and short DP-LIBS method.

  1. libChEBI: an API for accessing the ChEBI database.

    Science.gov (United States)

    Swainston, Neil; Hastings, Janna; Dekker, Adriano; Muthukrishnan, Venkatesh; May, John; Steinbeck, Christoph; Mendes, Pedro

    2016-01-01

    ChEBI is a database and ontology of chemical entities of biological interest. It is widely used as a source of identifiers to facilitate unambiguous reference to chemical entities within biological models, databases, ontologies and literature. ChEBI contains a wealth of chemical data, covering over 46,500 distinct chemical entities, and related data such as chemical formula, charge, molecular mass, structure, synonyms and links to external databases. Furthermore, ChEBI is an ontology, and thus provides meaningful links between chemical entities. Unlike many other resources, ChEBI is fully human-curated, providing a reliable, non-redundant collection of chemical entities and related data. While ChEBI is supported by a web service for programmatic access and a number of download files, it does not have an API library to facilitate the use of ChEBI and its data in cheminformatics software. To provide this missing functionality, libChEBI, a comprehensive API library for accessing ChEBI data, is introduced. libChEBI is available in Java, Python and MATLAB versions from http://github.com/libChEBI, and provides full programmatic access to all data held within the ChEBI database through a simple and documented API. libChEBI is reliant upon the (automated) download and regular update of flat files that are held locally. As such, libChEBI can be embedded in both on- and off-line software applications. libChEBI allows better support of ChEBI and its data in the development of new cheminformatics software. Covering three key programming languages, it allows for the entirety of the ChEBI database to be accessed easily and quickly through a simple API. All code is open access and freely available.

  2. The use and effectiveness of the eLib subject gateways: a preliminary investigation

    OpenAIRE

    Mackie, M.; Burton, P.F.

    1999-01-01

    Internet subject gateways were set up under the Electronic Libraries Programme (eLib) in order to address some of the problems of searching the Internet which have been identified by information professionals, i.e. locating relevant, good quality information. This preliminary study examines the extent to which academics in two universities use three eLib subject gateways (EEVL, OMNI and SOSIG). The results are generally encouraging for the eLib programme, but it is necessary for the gateways ...

  3. Fast LIBS Identification of Aluminum Alloys

    Directory of Open Access Journals (Sweden)

    Tawfik W.

    2007-04-01

    Full Text Available Laser-induced breakdown spectroscopy (LIBS has been applied to analysis aluminum alloy targets. The plasma is generated by focusing a 300 mJ pulsed Nd: YAG laser on the target in air at atmospheric pressure. Such plasma emission spectrum was collected using a one-meter length wide band fused-silica optical fiber connected to a portable Echelle spectrometer with intensified CCD camera. Spectroscopic analysis of plasma evolution of laser produced plasmas has been characterized in terms of their spectra, electron density and electron temperature assuming the LTE and optically thin plasma conditions. The LIBS spectrum was optimized for high S/N ratio especially for trace elements. The electron temperature and density were determined using the emission intensity and stark broadening, respectively, of selected aluminum spectral lines. The values of these parameters were found to change with the aluminum alloy matrix, i.e. they could be used as a fingerprint character to distinguish between different aluminum alloy matrices using only one major element (aluminum without needing to analysis the rest of elements in the matrix. Moreover, It was found that the values of T e and N e decrease with increasing the trace elements concentrations in the aluminum alloy samples. The obtained results indicate that it is possible to improve the exploitation of LIBS in the remote on-line industrial monitoring application, by following up only the values of T e and N e for aluminum in aluminum alloys as a marker for the correct alloying using an optical fiber probe.

  4. Feasibility of laser-induced breakdown spectroscopy (LIBS) for classification of sea salts.

    Science.gov (United States)

    Tan, Man Minh; Cui, Sheng; Yoo, Jonghyun; Han, Song-Hee; Ham, Kyung-Sik; Nam, Sang-Ho; Lee, Yonghoon

    2012-03-01

    We have investigated the feasibility of laser-induced breakdown spectroscopy (LIBS) as a fast, reliable classification tool for sea salts. For 11 kinds of sea salts, potassium (K), magnesium (Mg), calcium (Ca), and aluminum (Al), concentrations were measured by inductively coupled plasma-atomic emission spectroscopy (ICP-AES), and the LIBS spectra were recorded in the narrow wavelength region between 760 and 800 nm where K (I), Mg (I), Ca (II), Al (I), and cyanide (CN) band emissions are observed. The ICP-AES measurements revealed that the K, Mg, Ca, and Al concentrations varied significantly with the provenance of each salt. The relative intensities of the K (I), Mg (I), Ca (II), and Al (I) peaks observed in the LIBS spectra are consistent with the results using ICP-AES. The principal component analysis of the LIBS spectra provided the score plot with quite a high degree of clustering. This indicates that classification of sea salts by chemometric analysis of LIBS spectra is very promising. Classification models were developed by partial least squares discriminant analysis (PLS-DA) and evaluated. In addition, the Al (I) peaks enabled us to discriminate between different production methods of the salts. © 2012 Society for Applied Spectroscopy

  5. Analysis of LiSn alloy at several depths using LIBS

    Energy Technology Data Exchange (ETDEWEB)

    Suchoňová, M., E-mail: maria.suchonova@fmph.uniba.sk [Dept. of Experimental Physics, Faculty of Mathematics Physics and Informatics, Comenius University in Bratislava, Mlynská dolina F2, 842 48 Bratislava (Slovakia); Krištof, J.; Pribula, M. [Dept. of Experimental Physics, Faculty of Mathematics Physics and Informatics, Comenius University in Bratislava, Mlynská dolina F2, 842 48 Bratislava (Slovakia); Veis, M. [Dept. of Inorganic Chemistry, Faculty of Natural Science, Comenius University, Mlynská dolina, Ilkovičova 6, 842 15 Bratislava 4 (Slovakia); Tabarés, F.L. [Fusion Department, Ciemat, Av Complutense 40, 28040 Madrid (Spain); Veis, P., E-mail: pavel.veis@fmph.uniba.sk [Dept. of Experimental Physics, Faculty of Mathematics Physics and Informatics, Comenius University in Bratislava, Mlynská dolina F2, 842 48 Bratislava (Slovakia)

    2017-04-15

    The difference between the composition of the surface and the inner part of the LiSn sample was studied using Calibration Free Laser Induced Breakdown Spectroscopy (CF-LIBS) method. The sample was analysed under the low pressure (1330 Pa) in Ar atmosphere. The spectra were record using Echelle spectrometer (Mechelle ME5000). Gate delay and gate width was optimised and set to 300 ns. In order to analyse depth profile the LIBS spectra was recorded after each laser shot. The electron density analysed by laser induced plasma was determined separately for each laser shot, which means for each ablated layer of investigated sample. The difference between the individual shots taken at distinct sites of the sample are shown. The CF-LIBS method was used to determine the elemental composition near the surface and in the central part of the LiSn sample.

  6. A combined remote Raman and LIBS instrument for characterizing minerals with 532 nm laser excitation.

    Science.gov (United States)

    Sharma, Shiv K; Misra, Anupam K; Lucey, Paul G; Lentz, Rachel C F

    2009-08-01

    The authors have developed an integrated remote Raman and laser-induced breakdown spectroscopy (LIBS) system for measuring both the Raman and LIBS spectra of minerals with a single 532 nm laser line of 35 mJ/pulse and 20 Hz. The instrument has been used for analyzing both Raman and LIBS spectra of carbonates, sulfates, hydrous and anhydrous silicates, and iron oxide minerals in air. These experiments demonstrate that by focusing a frequency-doubled 532 nm Nd:YAG pulsed laser beam with a 10x beam expander to a 529-microm diameter spot on a mineral surface located at 9 m, it is possible to measure simultaneously both the remote Raman and LIBS spectra of calcite, gypsum and olivine by adjusting the laser power electronically. The spectra of calcite, gypsum, and olivine contain fingerprint Raman lines; however, it was not possible to measure the remote Raman spectra of magnetite and hematite at 9 m because of strong absorption of 532 nm laser radiation and low intensities of Raman lines from these minerals. The remote LIBS spectra of both magnetite and hematite contain common iron emission lines but show difference in the minor amount of Li present in these two minerals. Remote Raman and LIBS spectra of a number of carbonates, sulfates, feldspars and phyllosilicates at a distance of 9 m were measured with a 532-nm laser operating at 35 mJ/pulse and by changing photon flux density at the sample by varying the spot diameter from 10 mm for Raman to 530 microm for LIBS measurements. The complementary nature of these spectra is highlighted and discussed. The combined Raman and LIBS system can also be re-configured to perform micro-Raman and micro-LIBS analyses, which have applications in trace/residue analysis and analysis of very small samples in the nano-gram range.

  7. Characterization and forensic analysis of soil samples using laser-induced breakdown spectroscopy (LIBS).

    Science.gov (United States)

    Jantzi, Sarah C; Almirall, José R

    2011-07-01

    A method for the quantitative elemental analysis of surface soil samples using laser-induced breakdown spectroscopy (LIBS) was developed and applied to the analysis of bulk soil samples for discrimination between specimens. The use of a 266 nm laser for LIBS analysis is reported for the first time in forensic soil analysis. Optimization of the LIBS method is discussed, and the results compared favorably to a laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) method previously developed. Precision for both methods was LIBS limits of detection were LIBS method successfully discriminated samples from two different sites in Dade County, FL. Analysis of variance, Tukey's post hoc test and Student's t test resulted in 100% discrimination with no type I or type II errors. Principal components analysis (PCA) resulted in clear groupings of the two sites. A correct classification rate of 99.4% was obtained with linear discriminant analysis using leave-one-out validation. Similar results were obtained when the same samples were analyzed by LA-ICP-MS, showing that LIBS can provide similar information to LA-ICP-MS. In a forensic sampling/spatial heterogeneity study, the variation between sites, between sub-plots, between samples and within samples was examined on three similar Dade sites. The closer the sampling locations, the closer the grouping on a PCA plot and the higher the misclassification rate. These results underscore the importance of careful sampling for geographic site characterization.

  8. Optimalizace experimentálních parametrů v sestavě dvoupulzní LIBS

    OpenAIRE

    Roščák, Michal

    2010-01-01

    V diplomovej práci je opísaná metóda spektroskopie laserom indukovanej plazmy (LIBS) ako aj možnosť zníženia detekčných limitov použitím metódy dvojpulznej LIBS (DP-LIBS). Práca taktiež pojednáva o vlastnostiach laserom indukovanej plazmy (LIP). Obsahuje opis DP-LIBS aparatúry laboratória laserovej spektroskopie Fakulty strojního inženýrství, Vysoké učení technické v Brně, ako aj postup optimalizácie jej parametrov. Optimalizácia bola vykonaná pre detekciu chrómu v oceli s ohľadom na detekčné...

  9. Novel high-density packaging of solid state diode pumped eye-safe laser for LIBS

    Science.gov (United States)

    Bares, Kim; Torgerson, Justin; McNeil, Laine; Maine, Patrick; Patterson, Steve

    2018-02-01

    Laser-Induced Breakdown Spectroscopy (LIBS) has proven to be a useful research tool for material analysis for decades. However, because of the amount of energy required in a few nanosecond pulse to generate a stable and reliable LIBS signal, the lasers are often large and inefficient, relegating their implementation to research facilities, factory floors, and assembly lines. Small portable LIBS systems are now possible without having to compromise on energy needs by leveraging off of advances in high-density packaging of electronics, opto-mechanics, and highly efficient laser resonator architecture. This paper explores the integration of these techniques to achieve a mJ class eye-safe LIBS laser source, while retaining a small, light-weight package suitable for handheld systems.

  10. The effect of nutrient media water purity on LIBS based identification of bacteria

    Science.gov (United States)

    Single pulse laser induced breakdown spectroscopy (LIBS) is used as the basis for discrimination between 3 genera of Gram-negative bacteria and 2 genera of gram-positive bacteria representing pathogenic threats commonly found in poultry processing rinse waters. Because LIBS-based discrimination reli...

  11. [An automatic peak detection method for LIBS spectrum based on continuous wavelet transform].

    Science.gov (United States)

    Chen, Peng-Fei; Tian, Di; Qiao, Shu-Jun; Yang, Guang

    2014-07-01

    Spectrum peak detection in the laser-induced breakdown spectroscopy (LIBS) is an essential step, but the presence of background and noise seriously disturb the accuracy of peak position. The present paper proposed a method applied to automatic peak detection for LIBS spectrum in order to enhance the ability of overlapping peaks searching and adaptivity. We introduced the ridge peak detection method based on continuous wavelet transform to LIBS, and discussed the choice of the mother wavelet and optimized the scale factor and the shift factor. This method also improved the ridge peak detection method with a correcting ridge method. The experimental results show that compared with other peak detection methods (the direct comparison method, derivative method and ridge peak search method), our method had a significant advantage on the ability to distinguish overlapping peaks and the precision of peak detection, and could be be applied to data processing in LIBS.

  12. Detection of Anomalies in Citrus Leaves Using Laser-Induced Breakdown Spectroscopy (LIBS).

    Science.gov (United States)

    Sankaran, Sindhuja; Ehsani, Reza; Morgan, Kelly T

    2015-08-01

    Nutrient assessment and management are important to maintain productivity in citrus orchards. In this study, laser-induced breakdown spectroscopy (LIBS) was applied for rapid and real-time detection of citrus anomalies. Laser-induced breakdown spectroscopy spectra were collected from citrus leaves with anomalies such as diseases (Huanglongbing, citrus canker) and nutrient deficiencies (iron, manganese, magnesium, zinc), and compared with those of healthy leaves. Baseline correction, wavelet multivariate denoising, and normalization techniques were applied to the LIBS spectra before analysis. After spectral pre-processing, features were extracted using principal component analysis and classified using two models, quadratic discriminant analysis and support vector machine (SVM). The SVM resulted in a high average classification accuracy of 97.5%, with high average canker classification accuracy (96.5%). LIBS peak analysis indicated that high intensities at 229.7, 247.9, 280.3, 393.5, 397.0, and 769.8 nm were observed of 11 peaks found in all the samples. Future studies using controlled experiments with variable nutrient applications are required for quantification of foliar nutrients by using LIBS-based sensing.

  13. Gallium Content in PuO2 Using Laser Induced Breakdown Spectroscopy (LIBS)

    International Nuclear Information System (INIS)

    Smith, C.A.; Martinez, M.A.; Veirs, D.K.

    1999-01-01

    Laser Induced Breakdown Spectroscopy (LIBS) has been applied to the semi-quantitative analysis of gallium in plutonium oxide at the Los Alamos Plutonium Facility. The oxide samples were generated by the Thermally Induced Gallium Removal (TIGR) process, a pretreatment step prior to MOX fuel processing. The TIGR process uses PuO 2 containing 1 wt% gallium (nominal) as feed material. Following the TIGR process, gallium content was analyzed by LIBS and also by conventional wet chemical analysis (ICP-MS). Although the data range was insufficient to obtain an adequate calibration, general agreement between the two techniques was good. LIBS was found to have a useful analytical range of 34-400 ppm for Ga in PuO 2

  14. Monitoring of toxic elements present in sludge of industrial waste using CF-LIBS.

    Science.gov (United States)

    Kumar, Rohit; Rai, Awadhesh K; Alamelu, Devanathan; Aggarwal, Suresh K

    2013-01-01

    Industrial waste is one of the main causes of environmental pollution. Laser-induced breakdown spectroscopy (LIBS) was applied to detect the toxic metals in the sludge of industrial waste water. Sludge on filter paper was obtained after filtering the collected waste water samples from different sections of a water treatment plant situated in an industrial area of Kanpur City. The LIBS spectra of the sludge samples were recorded in the spectral range of 200 to 500 nm by focusing the laser light on sludge. Calibration-free laser-induced breakdown spectroscopy (CF-LIBS) technique was used for the quantitative measurement of toxic elements such as Cr and Pb present in the sample. We also used the traditional calibration curve approach to quantify these elements. The results obtained from CF-LIBS are in good agreement with the results from the calibration curve approach. Thus, our results demonstrate that CF-LIBS is an appropriate technique for quantitative analysis where reference/standard samples are not available to make the calibration curve. The results of the present experiment are alarming to the people living nearby areas of industrial activities, as the concentrations of toxic elements are quite high compared to the admissible limits of these substances.

  15. Quantitative analysis of titanium concentration using calibration-free laser-induced breakdown spectroscopy (LIBS)

    Science.gov (United States)

    Zaitun; Prasetyo, S.; Suliyanti, M. M.; Isnaeni; Herbani, Y.

    2018-03-01

    Laser-induced breakdown spectroscopy (LIBS) can be used for quantitative and qualitative analysis. Calibration-free LIBS (CF-LIBS) is a method to quantitatively analyze concentration of elements in a sample in local thermodynamic equilibrium conditions without using available matrix-matched calibration. In this study, we apply CF-LIBS for quantitative analysis of Ti in TiO2 sample. TiO2 powder sample was mixed with polyvinyl alcohol and formed into pellets. An Nd:YAG pulsed laser at a wavelength of 1064 nm was focused onto the sample to generate plasma. The spectrum of plasma was recorded using spectrophotometer then compared to NIST spectral line to determine energy levels and other parameters. The value of plasma temperature obtained using Boltzmann plot is 8127.29 K and electron density from calculation is 2.49×1016 cm-3. Finally, the concentration of Ti in TiO2 sample from this study is 97% that is in proximity with the sample certificate.

  16. Laser-induced breakdown spectroscopy (LIBS): an overview of recent progress and future potential for biomedical applications.

    Science.gov (United States)

    Rehse, S J; Salimnia, H; Miziolek, A W

    2012-02-01

    The recent progress made in developing laser-induced breakdown spectroscopy (LIBS) has transformed LIBS from an elemental analysis technique to one that can be applied for the reagentless analysis of molecularly complex biological materials or clinical specimens. Rapid advances in the LIBS technology have spawned a growing number of recently published articles in peer-reviewed journals which have consistently demonstrated the capability of LIBS to rapidly detect, biochemically characterize and analyse, and/or accurately identify various biological, biomedical or clinical samples. These analyses are inherently real-time, require no sample preparation, and offer high sensitivity and specificity. This overview of the biomedical applications of LIBS is meant to summarize the research that has been performed to date, as well as to suggest to health care providers several possible specific future applications which, if successfully implemented, would be significantly beneficial to humankind.

  17. Applications of Laser-Induced Breakdown Spectroscopy (LIBS) in Molten Metal Processing

    Science.gov (United States)

    Hudson, Shaymus W.; Craparo, Joseph; De Saro, Robert; Apelian, Diran

    2017-10-01

    In order for metals to meet the demand for critical applications in the automotive, aerospace, and defense industries, tight control over the composition and cleanliness of the metal must be achieved. The use of laser-induced breakdown spectroscopy (LIBS) for applications in metal processing has generated significant interest for its ability to perform quick analyses in situ. The fundamentals of LIBS, current techniques for deployment on molten metal, demonstrated capabilities, and possible avenues for development are reviewed and discussed.

  18. ANALISIS KUALITATIF PADA BATU KECUBUNG KOPI MENGGUNAKAN LIBS

    Directory of Open Access Journals (Sweden)

    Ida Ayu Gede Kusuma Dewi

    2016-08-01

    Full Text Available It has been conducted research on the qualitative analysis on amethyst coffee using LIBS.This study aims to determine the content of the element in amethyst coffee that can later be used as a comparison or reference further research in the elemental analysis amethyst coffee. With treatment, the laser irradiated amethyst coffee at 100 mJ, and the data retrieved by the accumulation of 3, delay time 1 µs and repetition as much as 3 points in different areas of each region analysis of depth function (Depth Profile with 60 times the laser irradiation. The main element as a constituent amethyst Coffee is silicon (Si, Sodium (Na, calcium (Ca, potassium (K and oxygen (O2, while the element on its outer surface is iron (Fe and phosphorus (P were analyzed using LIBS.

  19. Development of LIBS for online analysis of solid nuclear materials

    International Nuclear Information System (INIS)

    Picard, Jessica

    2015-01-01

    With the objective to implement a fast, online analysis technique for control of solid metal nuclear materials, laser-induced breakdown spectroscopy (LIBS) technique is developed for quantitative analysis in uranium and plutonium. Since these matrices have a very dense emission spectrum in the UV-Visible range, the Vacuum Ultra-Violet (VUV) spectral range, less rich in lines, is explored. The aim of this thesis is to perform the analytical development of VUV-LIBS for quantitative analysis between 500 and 5000 ppm with an uncertainty of 3%. For that purpose, four steps were defined. First, for practical and safety reasons, it is generally better to perform experiments on surrogate materials. LIBS based on laser-material interaction, it is relevant to seek a surrogate of material of interest from the viewpoint of the ablated mass. Thus, a complete study of laser ablation of several metals was enabled to build a predictive model of the ablation efficiency. Titanium and stainless steel were defined as surrogate materials of plutonium and uranium for laser ablation. Secondly, the VUV-LIBS setup analytical performances were optimized for several elements of interest in four metals. Then, two calibration methods are used to determine the analytical performances. The limits of quantification are of the order of a few hundreds of ppm for all studied matrices, which validates the objective of impurities quantitation in the 500-5000 ppm range. Uncertainty is lower than 3% in the best cases. Finally, the calibration transfer between the four matrices was studied. A normalization of the nickel net signal measured in three matrices was presented. (author) [fr

  20. Feasibility Study for Monitoring Actinide Elements in Process Materials Using FO-LIBS at Advanced spent fuel Conditioning Process Facility

    Energy Technology Data Exchange (ETDEWEB)

    Han, Bo-Young; Choi, Daewoong; Park, Se Hwan; Kim, Ho-Dong [Nonproliferation System Research Division, Korea Atomic Energy Research Institute, Daejeon, 305-353 (Korea, Republic of); Dae, Dongsun [Department of Chemistry, Mokpo National University, Jeonnam 534-729 (Korea, Republic of); Whitehouse, Andrew I. [Applied Photonics Ltd., Unit 8 Carleton Business Park, Skipton, North Yorkshire BD23 2DE (United Kingdom)

    2015-07-01

    Korea Atomic Energy Research Institute (KAERI) have been developing the design and deployment methodology of Laser- Induced Breakdown Spectroscopy (LIBS) instrument for safeguards application within the argon hot cell environment at Advanced spent fuel Conditioning Process Facility (ACPF), where ACPF is a facility being refurbished for the laboratory-scaled demonstration of advanced spent fuel conditioning process. LIBS is an analysis technology used to measure the emission spectra of excited elements in the local plasma of a target material induced by a laser. The spectra measured by LIBS are analyzed to verify the quality and quantity of the specific element in the target matrix. Recently LIBS has been recognized as a promising technology for safeguards purposes in terms of several advantages including a simple sample preparation and in-situ analysis capability. In particular, a feasibility study of LIBS to remotely monitor the nuclear material in a high radiation environment has been carried out for supporting the IAEA safeguards implementation. Fiber-Optic LIBS (FO-LIBS) deployment was proposed by Applied Photonics Ltd because the use of fiber optics had benefited applications of LIBS by delivering the laser energy to the target and by collecting the plasma light. The design of FO-LIBS instrument for the measurement of actinides in the spent fuel and high temperature molten salt at ACPF had been developed in cooperation with Applied Photonics Ltd. FO-LIBS has some advantages as followings: the detectable plasma light wavelength range is not limited by the optical properties of the thick lead-glass shield window and the potential risk of laser damage to the lead-glass shield window is not considered. The remote LIBS instrument had been installed at ACPF and then the feasibility study for monitoring actinide elements such as uranium, plutonium, and curium in process materials has been carried out. (authors)

  1. Feasibility Study for Monitoring Actinide Elements in Process Materials Using FO-LIBS at Advanced spent fuel Conditioning Process Facility

    International Nuclear Information System (INIS)

    Han, Bo-Young; Choi, Daewoong; Park, Se Hwan; Kim, Ho-Dong; Dae, Dongsun; Whitehouse, Andrew I.

    2015-01-01

    Korea Atomic Energy Research Institute (KAERI) have been developing the design and deployment methodology of Laser- Induced Breakdown Spectroscopy (LIBS) instrument for safeguards application within the argon hot cell environment at Advanced spent fuel Conditioning Process Facility (ACPF), where ACPF is a facility being refurbished for the laboratory-scaled demonstration of advanced spent fuel conditioning process. LIBS is an analysis technology used to measure the emission spectra of excited elements in the local plasma of a target material induced by a laser. The spectra measured by LIBS are analyzed to verify the quality and quantity of the specific element in the target matrix. Recently LIBS has been recognized as a promising technology for safeguards purposes in terms of several advantages including a simple sample preparation and in-situ analysis capability. In particular, a feasibility study of LIBS to remotely monitor the nuclear material in a high radiation environment has been carried out for supporting the IAEA safeguards implementation. Fiber-Optic LIBS (FO-LIBS) deployment was proposed by Applied Photonics Ltd because the use of fiber optics had benefited applications of LIBS by delivering the laser energy to the target and by collecting the plasma light. The design of FO-LIBS instrument for the measurement of actinides in the spent fuel and high temperature molten salt at ACPF had been developed in cooperation with Applied Photonics Ltd. FO-LIBS has some advantages as followings: the detectable plasma light wavelength range is not limited by the optical properties of the thick lead-glass shield window and the potential risk of laser damage to the lead-glass shield window is not considered. The remote LIBS instrument had been installed at ACPF and then the feasibility study for monitoring actinide elements such as uranium, plutonium, and curium in process materials has been carried out. (authors)

  2. Fire debris analysis for forensic fire investigation using laser induced breakdown spectroscopy (LIBS)

    Science.gov (United States)

    Choi, Soojin; Yoh, Jack J.

    2017-08-01

    The possibility verification of the first attempt to apply LIBS to arson investigation was performed. LIBS has capabilities for real time in-situ analysis and depth profiling. It can provide valuable information about the fire debris that are complementary to the classification of original sample components and combustion residues. In this study, fire debris was analyzed to determine the ignition source and existence of a fire accelerant using LIBS spectra and depth profiling analysis. Fire debris chemical composition and carbon layer thickness determines the possible ignition source while the carbon layer thickness of combusted samples represents the degree of sample carbonization. When a sample is combusted with fire accelerants, a thicker carbon layer is formed because the burning rate is increased. Therefore, depth profiling can confirm the existence of combustion accelerants, which is evidence of arson. Also investigation of fire debris by depth profiling is still possible when a fire is extinguished with water from fire hose. Such data analysis and in-situ detection of forensic signals via the LIBS may assist fire investigation at crime scenes.

  3. LIBS: study of elemental profile of different layers of the optical window of Tokamak

    International Nuclear Information System (INIS)

    Maurya, Gulab Singh; Jyotsna, Aradhana; Rai, Awadhesh Kumar; Ajai Kumar

    2012-01-01

    In the Tokamak, during confinement of plasma, impurities are deposited on optical window, mirror, limiters, etc. of the tokamak. Thus a layer of impurity on the surface of the optical window causes less visibility which creates problem in the study of plasma parameters and other diagnostics of the plasma generated in the tokamak. Laser Induced Breakdown Spectroscopy (LIBS) is a useful atomic spectroscopic technique for analysis of materials in any phase (Solid, Liquid, Gas etc). LIBS spectra of optical window have been recorded in the spectral range of 200-500 nm. In present study we have focused laser on the surface of the window, to study the layer-wise elemental profile of optical window, we have recorded the LIBS spectra with increasing number of laser shots on the same point of the window. In first laser shot, spectral signature of Cr, Fe, and Ni etc. are present in the LIBS spectra, which is related with the impurity but after five to six laser shots at the same point of the optical window spectral signature Si, B are observed which is related to the glass material. Thus our study demonstrates the capability of LIBS as an in-situ monitoring tool for detection of elemental profile in different layers of optical window of the Tokamak. (author)

  4. Does LibQUAL+[TM] Account for Student Loyalty to a University College Library?

    Science.gov (United States)

    Helgesen, Oyvind; Nesset, Erik

    2011-01-01

    Purpose: The purpose of this paper is to find out whether LibQUAL+[TM]can account for student loyalty to the library of an institution of higher education. LibQUAL+[TM] is a marketing tool that is used to measure perceived service quality of libraries, and the present analysis aims at validating this service quality instrument within a more…

  5. Rapid detection of soils contaminated with heavy metals and oils by laser induced breakdown spectroscopy (LIBS).

    Science.gov (United States)

    Kim, Gibaek; Kwak, Jihyun; Kim, Ki-Rak; Lee, Heesung; Kim, Kyoung-Woong; Yang, Hyeon; Park, Kihong

    2013-12-15

    A laser induced breakdown spectroscopy (LIBS) coupled with the chemometric method was applied to rapidly discriminate between soils contaminated with heavy metals or oils and clean soils. The effects of the water contents and grain sizes of soil samples on LIBS emissions were also investigated. The LIBS emission lines decreased by 59-75% when the water content increased from 1.2% to 7.8%, and soil samples with a grain size of 75 μm displayed higher LIBS emission lines with lower relative standard deviations than those with a 2mm grain size. The water content was found to have a more pronounced effect on the LIBS emission lines than the grain size. Pelletizing and sieving were conducted for all samples collected from abandoned mining areas and military camp to have similar water contents and grain sizes before being analyzed by the LIBS with the chemometric analysis. The data show that three types of soil samples were clearly discerned by using the first three principal components from the spectral data of soil samples. A blind test was conducted with a 100% correction rate for soil samples contaminated with heavy metals and oil residues. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. In situ semi-quantitative analysis of polluted soils by laser-induced breakdown spectroscopy (LIBS).

    Science.gov (United States)

    Ismaël, Amina; Bousquet, Bruno; Michel-Le Pierrès, Karine; Travaillé, Grégoire; Canioni, Lionel; Roy, Stéphane

    2011-05-01

    Time-saving, low-cost analyses of soil contamination are required to ensure fast and efficient pollution removal and remedial operations. In this work, laser-induced breakdown spectroscopy (LIBS) has been successfully applied to in situ analyses of polluted soils, providing direct semi-quantitative information about the extent of pollution. A field campaign has been carried out in Brittany (France) on a site presenting high levels of heavy metal concentrations. Results on iron as a major component as well as on lead and copper as minor components are reported. Soil samples were dried and prepared as pressed pellets to minimize the effects of moisture and density on the results. LIBS analyses were performed with a Nd:YAG laser operating at 1064 nm, 60 mJ per 10 ns pulse, at a repetition rate of 10 Hz with a diameter of 500 μm on the sample surface. Good correlations were obtained between the LIBS signals and the values of concentrations deduced from inductively coupled plasma atomic emission spectroscopy (ICP-AES). This result proves that LIBS is an efficient method for optimizing sampling operations. Indeed, "LIBS maps" were established directly on-site, providing valuable assistance in optimizing the selection of the most relevant samples for future expensive and time-consuming laboratory analysis and avoiding useless analyses of very similar samples. Finally, it is emphasized that in situ LIBS is not described here as an alternative quantitative analytical method to the usual laboratory measurements but simply as an efficient time-saving tool to optimize sampling operations and to drastically reduce the number of soil samples to be analyzed, thus reducing costs. The detection limits of 200 ppm for lead and 80 ppm for copper reported here are compatible with the thresholds of toxicity; thus, this in situ LIBS campaign was fully validated for these two elements. Consequently, further experiments are planned to extend this study to other chemical elements and other

  7. Combined Raman/LIBS spectrometer elegant breadboard: built and tested - and flight model spectrometer unit

    Science.gov (United States)

    Ahlers, B.; Hutchinson, I.; Ingley, R.

    2017-11-01

    A spectrometer for combined Raman and Laser Induced Breakdown Spectroscopy (LIBS) is amongst the different instruments that have been pre-selected for the Pasteur payload of the ExoMars rover. It is regarded as a fundamental, next-generation instrument for organic, mineralogical and elemental characterisation of Martian soil, rock samples and organic molecules. Raman spectroscopy and LIBS will be integrated into a single instrument sharing many hardware commonalities [1]. The combined Raman / LIBS instrument has been recommended as the highest priority mineralogy instrument to be included in the rover's analytical laboratory for the following tasks: Analyse surface and sub-surface soil and rocks on Mars, identify organics in the search for life and determine soil origin & toxicity. The synergy of the system is evident: the Raman spectrometer is dedicated to molecular analysis of organics and minerals; the LIBS provides information on the sample's elemental composition. An international team, under ESA contract and with the leadership of TNO Science and Industry, has built and tested an Elegant Bread Board (EBB) of the combined Raman / LIBS instrument. The EBB comprises a specifically designed, extremely compact, spectrometer with high resolution over a large wavelength range, suitable for both Raman spectroscopy and LIBS measurements. The EBB also includes lasers, illumination and imaging optics as well as fibre optics for light transfer. A summary of the functional and environmental requirements together with a description of the optical design and its expected performance are described in [2]. The EBB was developed and constructed to verify the instruments' end-to-end functional performance with natural samples. The combined Raman / LIBS EBB realisation and test results of natural samples will be presented. For the Flight Model (FM) instrument, currently in the design phase, the Netherlands will be responsible for the design, development and verification of the

  8. A Simple LIBS (Laser-Induced Breakdown Spectroscopy) Laboratory Experiment to Introduce Undergraduates to Calibration Functions and Atomic Spectroscopy

    Science.gov (United States)

    Chinni, Rosemarie C.

    2012-01-01

    This laboratory experiment introduces students to a different type of atomic spectroscopy: laser-induced breakdown spectroscopy (LIBS). LIBS uses a laser-generated spark to excite the sample; once excited, the elemental emission is spectrally resolved and detected. The students use LIBS to analyze a series of standard synthetic silicate samples…

  9. Comparison of LIBS and {mu}-XRF measurements on bronze alloys for monitoring plasma effects

    Energy Technology Data Exchange (ETDEWEB)

    Alberghina, M F; Barraco, R; Brai, M; Schillaci, T; Tranchina, L, E-mail: tschillaci@unipa.it [Dipartimento di Fisica e Tecnologie Relative, Universita di Palermo, Viale delle Scienze Ed. 18, 90128 Palermo (Italy)

    2011-01-01

    The laser-induced breakdown spectroscopy (LIBS) technique is often used as atomic spectroscopic technique for elemental analysis of materials. However, it presents some drawbacks that make an accurate quantitative analysis difficult. Since the plasma properties, such as spatial inhomogeneity and plume stoichiometry strongly depend on the experimental conditions, the measurements are less reproducible. In order to evaluate the measurement fluctuations, we propose to use the more established micro X-Ray fluorescence ({mu}-XRF) technique for validating LIBS data. In particular, the quantitative data, obtained by varying the laser fluence, the shot numbers and the temporal acquisition parameters, were compared with those obtained by {mu}-XRF on laboratory made samples of binary, ternary and quaternary bronze alloys. For LIBS measurements a mobile double pulse laser instrument equipped with an high resolution Echelle type monochromator coupled to an intensified CCD camera was used. {mu}-XRF analyses were performed with a portable instrument that uses a micro collimated X-Ray beam and it is equipped with an high resolution detector. The LIBS results show a strong dependence both on the instrumental set up and the chemical-physical properties of the sample. With our findings we could identify the most suitable parameters to be used in the investigation of the different bronze alloys. The possibility to carry out a quantitative analysis by using the LIBS technique was checked through the comparison with related {mu}-XRF data. In particular in this paper we identified a set of reliable LIBS parameters for the quantitative analysis of copper, tin and zinc. Further analyses will be necessary to reach this goal also for the minor constituents as lead.

  10. Effects of laser wavelengths and pulse energy ratio on the emission enhancement in dual pulse LIBS

    International Nuclear Information System (INIS)

    Ahmed, Rizwan; Iqbal, Javed; Baig, M Aslam

    2015-01-01

    We present new studies on the effects of laser wavelengths, pulse energy ratio and interpulse delay between two laser pulses in the collinear dual pulse configuration of laser-induced breakdown spectroscopy (LIBS) on an iron sample in air using the fundamental (1064 nm) and the second harmonics (532 nm) of Nd:YAG lasers. In the dual pulse LIBS, an optimum value of interpulse delay with an appropriate combination of laser wavelengths, and laser pulse energy ratio, yields a 30 times signal intensity enhancement in the neutral iron lines as compared with single pulse LIBS. A comparison in the spatial variations of electron temperature along the axis of the plume expansion in single and double pulse LIBS has also been studied. (letter)

  11. New Library, New Librarian, New Student: Using LibGuides to Reach the Virtual Student

    Science.gov (United States)

    Roberts, Sara; Hunter, Dwight

    2011-01-01

    This article examines the virtual pathfinder and its relationship with distance education students. Various topics are addressed in relation to virtual students, LibGuides and collaborative efforts between librarians and teaching faculty. A brief history of the subject guide is presented, advantages and disadvantages of LibGuides are discussed and…

  12. Accuracy Enhancement of Raman Spectroscopy Using Complementary Laser-Induced Breakdown Spectroscopy (LIBS) with Geologically Mixed Samples.

    Science.gov (United States)

    Choi, Soojin; Kim, Dongyoung; Yang, Junho; Yoh, Jack J

    2017-04-01

    Quantitative Raman analysis was carried out with geologically mixed samples that have various matrices. In order to compensate the matrix effect in Raman shift, laser-induced breakdown spectroscopy (LIBS) analysis was performed. Raman spectroscopy revealed the geological materials contained in the mixed samples. However, the analysis of a mixture containing different matrices was inaccurate due to the weak signal of the Raman shift, interference, and the strong matrix effect. On the other hand, the LIBS quantitative analysis of atomic carbon and calcium in mixed samples showed high accuracy. In the case of the calcite and gypsum mixture, the coefficient of determination of atomic carbon using LIBS was 0.99, while the signal using Raman was less than 0.9. Therefore, the geological composition of the mixed samples is first obtained using Raman and the LIBS-based quantitative analysis is then applied to the Raman outcome in order to construct highly accurate univariate calibration curves. The study also focuses on a method to overcome matrix effects through the two complementary spectroscopic techniques of Raman spectroscopy and LIBS.

  13. Ultrasonic Nebulizer Assisted LIBS: a Promising Metal Elements Detection Method for Aqueous Sample Analysis

    International Nuclear Information System (INIS)

    Zhong Shilei; Zheng Ronger; Lu Yuan; Cheng Kai; Xiu Junshan

    2015-01-01

    A newly developed approach for trace metal elements detection for aqueous samples analysis is presented in this paper. The idea of this approach is to improve ablation efficiency by transforming the liquid sample into a dense cloud of droplets using an ultrasonic nebulizer. The resulting droplets are then subjected to analysis by laser induced breakdown spectroscopy (LIBS). A purpose-built ultrasonic nebulizer assisted LIBS (UN-LIBS) system has been applied to the analysis of aqueous samples at trace levels of concentration. Experimental investigations of solution samples were carried out with various dissolved trace metal elements (Mn, Zn, Cu, Pb, Fe, Mg and Na) using this approach. The characteristics of UN-LIBS signal of the elements were investigated regarding the lifetime and S/B ratio and the calibration curves for trace metal elements analyses. The obtained LODs are comparable or much better than the LODS of the reported signal enhancement approaches when the laser pulse energy was as low as 30 mJ. The good linearity of calibration curves and the low LODs shows the potential ability of this method for metal elements analysis application. The density of the electrons was calculated by measuring the Stark width of the line of H α . The possible mechanism of the LIBS signal enhancement of this approach was briefly discussed. (paper)

  14. [Rapid multi-elemental analysis on four precious Tibetan medicines based on LIBS technique].

    Science.gov (United States)

    Liu, Xiao-na; Shi, Xin-yuan; Jia, Shuai-yun; Zhao, Na; Wu, Zhi-sheng; Qiao, Yan-jiang

    2015-06-01

    The laser-induced breakdown spectroscopy (LIBS) was applied to perform a qualitative elementary analysis on four precious Tibetan medicines, i. e. Renqing Mangjue, Renqing Changjue, 25-herb coral pills and 25-herb pearl pills. The specific spectra of the four Tibetan medicines were established. In the experiment, Nd: YAG and 1 064 nm-baseband pulse laser were adopted to collect the spectra. A laser beam focused on the surface of the samples to generate plasma. Its spectral signal was detected by using spectrograph. Based on the National Institute of Standard and Technology (NIST) database, LIBS spectral lines were indentified. The four Tibetan medicines mainly included Ca, Na, K, Mg and other elements and C-N molecular band. Specifically, Fe was detected in Renqing Changjue and 25-herb pearl pills; heavy mental elements Hg and Cu were shown in Renqing Mangjue and Renqing Changjue; Ag was found in Renqing Changjue. The results demonstrated that LIBS is a reliable and rapid multi-element analysis on the four Tibetan medicines. With Real-time, rapid and nondestructive advantages, LIBS has a wide application prospect in the element analysis on ethnic medicines.

  15. In-vitro analysis of early calcification in aortic valvular interstitial cells using Laser-Induced Breakdown Spectroscopy (LIBS).

    Science.gov (United States)

    Davari, Seyyed Ali; Masjedi, Shirin; Ferdous, Zannatul; Mukherjee, Dibyendu

    2018-01-01

    Calcific aortic valve disease (CAVD) is a major cardiovascular disorder caused by osteogenic differentiation of valvular interstitial cells (VICs) within aortic valves. Conventional methods like colorimetric assays and histology fail to detect small calcium depositions during in-vitro VIC cultures. Laser-induced breakdown spectroscopy (LIBS) is a robust analytical tool used for inorganic materials characterizations, but relatively new to biomedical applications. We employ LIBS, for the first time, for quantitative in-vitro detection of calcium depositions in VICs at various osteogenic differentiation stages. VICs isolated from porcine aortic valves were cultured in osteogenic media over various days. Colorimetric calcium assays based on arsenazo dye and Von Kossa staining measured the calcium depositions within VICs. Simultaneously, LIBS signatures for Ca I (422.67 nm) atomic emission lines were collected for estimating calcium depositions in lyophilized VIC samples. Our results indicate excellent linear correlation between the calcium assay and our LIBS measurements. Furthermore, unlike the assay results, the LIBS results could resolve calcium signals from cell samples with as early as 2 days of osteogenic culture. Quantitatively, the LIBS measurements establish the limit of detection for calcium content in VICs to be ∼0.17±0.04 μg which indicates a 5-fold improvement over calcium assay. Picture: Quantitative LIBS enables in-vitro analysis for early stage detection of calcium deposition within aortic valvular interstitial cells (VICs). © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Final report on feasibility of real-time geochemical analysis at Yucca Mountain, Nevada, using LIBS technology

    International Nuclear Information System (INIS)

    Blacic, J.D.; Pettit, D.R.; Cremers, D.A.

    1996-12-01

    Laser-induced breakdown spectroscopy (LIBS) is an analytic method whereby an intense laser pulse is used to vaporize and excite a small volume of material into atomic emission. Calibrated spectral analysis of the laser spark light provides detection and quantification of the elemental composition of the target material. We performed laboratory and field tests to assess the feasibility of developing field-portable LIBS-based instruments for real-time analyses of Yucca Mountain rocks in conjunction with Yucca Mountain Project drilling, coring, sampling, and characterization tasks. We developed one prototype instrument designed to analyze air core drilling dust and another prototype instrument designed to analyze rock and fracture surfaces. In realistic field tests at the Exploratory Studies Facility at Yucca Mountain, Nevada, we demonstrated that the LIBS prototypes are capable of measuring major, minor, and some trace elements in real time. Laboratory LIBS analyses show that we can identify characteristic element ratios in a range of manganese oxide minerals present at Yucca Mountain as fracture surface coatings and matrix grains. Preliminary LIBS analyses also indicate that the U/Na ratio may distinguish tuffs containing the hazardous zeolite mineral erionite from non-erionite bearing tuffs, and that a LIBS-based instrument may be useful to detect in real time the probable presence of erionite encountered in core drilling and other operations at Yucca Mountain

  17. Calibration of the MSL/ChemCam/LIBS Remote Sensing Composition Instrument

    Science.gov (United States)

    Wiens, R. C.; Maurice S.; Bender, S.; Barraclough, B. L.; Cousin, A.; Forni, O.; Ollila, A.; Newsom, H.; Vaniman, D.; Clegg, S.; hide

    2011-01-01

    The ChemCam instrument suite on board the 2011 Mars Science Laboratory (MSL) Rover, Curiosity, will provide remote-sensing composition information for rock and soil samples within seven meters of the rover using a laser-induced breakdown spectroscopy (LIBS) system, and will provide context imaging with a resolution of 0.10 mradians using the remote micro-imager (RMI) camera. The high resolution is needed to image the small analysis footprint of the LIBS system, at 0.2-0.6 mm diameter. This fine scale analytical capability will enable remote probing of stratigraphic layers or other small features the size of "blueberries" or smaller. ChemCam is intended for rapid survey analyses within 7 m of the rover, with each measurement taking less than 6 minutes. Repeated laser pulses remove dust coatings and provide depth profiles through weathering layers, allowing detailed investigation of rock varnish features as well as analysis of the underlying pristine rock composition. The LIBS technique uses brief laser pulses greater than 10 MW/square mm to ablate and electrically excite material from the sample of interest. The plasma emits photons with wavelengths characteristic of the elements present in the material, permitting detection and quantification of nearly all elements, including the light elements H, Li, Be, B, C, N, O. ChemCam LIBS projects 14 mJ of 1067 nm photons on target and covers a spectral range of 240-850 nm with resolutions between 0.15 and 0.60 nm FWHM. The Nd:KGW laser is passively cooled and is tuned to provide maximum power output from -10 to 0 C, though it can operate at 20% degraded energy output at room temperature. Preliminary calibrations were carried out on the flight model (FM) in 2008. However, the detectors were replaced in 2009, and final calibrations occurred in April-June, 2010. This presentation describes the LIBS calibration and characterization procedures and results, and details plans for final analyses during rover system thermal testing

  18. Application and development of laser induced breakdown spectroscopy (LIBS) instrumentation for international safeguards

    Energy Technology Data Exchange (ETDEWEB)

    Barefield, II, James E.; Le, Loan; Lopez, Leon; Jolin, John L.; Clegg, Samuel M. [Chemical Diagnostic and Engineering and Physical Chemistry and Spectroscopy Los Alamos National Laboratory, Los Alamos, (United States)

    2011-12-15

    Advanced methodologies and improvements to current measurements techniques are needed to strengthen the effectiveness and efficiency of international safeguards. The primary tool employed by the IAEA to detect undeclared processes and activities at special nuclear material facilities and sites still is environmental sampling. This type of environmental sampling is both time consuming and costly since many samples must be collected, packaged, and shipped to an analytical laboratory for analysis that in some cases can take weeks to months to complete. Los Alamos National Laboratory is currently investigating potential uses of LIBS for safeguards applications, including(1) a user-friendly man-portable LIBS system to characterize samples in real to near-real time (typical analysis time are on the order of minutes) across a wide range of elements in the periodic table from hydrogen up to heavy elements like plutonium and uranium, (2) a LIBS system that can be deployed in harsh environments such as hot cells and glove boxes providing relative compositional analysis of process streams for example, ratios like Cm Division-Slash Pu and Cm Division-Slash / U, (3) an inspector field deployable system that can be used to analyze microscopic and single particle samples containing plutonium and uranium, and (4) a high resolution LIBS system that can be used to determine the isotopic composition of samples containing for example uranium and plutonium. In this paper, we will describe our current development and performance testing results for LIBS instrumentation both in a fixed lab and measurements in field deployable configurations.

  19. Qualitative evaluation of maternal milk and commercial infant formulas via LIBS.

    Science.gov (United States)

    Abdel-Salam, Z; Al Sharnoubi, J; Harith, M A

    2013-10-15

    This study focuses on the use of laser-induced breakdown spectroscopy (LIBS) for the evaluation of the nutrients in maternal milk and some commercially available infant formulas. The results of such evaluation are vital for adequate and healthy feeding for babies during lactation period. Laser-induced breakdown spectroscopy offers special advantages in comparison to the other conventional analytical techniques. Specifically, LIBS is a straightforward technique that can be used in situ to provide qualitative analytical information in few minutes for the samples under investigation without preparation processes. The samples studied in the current work were maternal milk samples collected during the first 3 months of lactation (not colostrum milk) and samples from six different types of commercially available infant formulas. The samples' elemental composition has been compared with respect to the relative abundance of the elements of nutrition importance, namely Mg, Ca, Na, and Fe using their spectral emission lines in the relevant LIBS spectra. In addition, CN and C2 molecular emission bands in the same spectra have been studied as indicators of proteins content in the samples. The obtained analytical results demonstrate the higher elemental contents of the maternal milk compared with the commercial formulas samples. Similar results have been obtained as for the proteins content. It has been also shown that calcium and proteins have similar relative concentration trends in the studied samples. This work demonstrates the feasibility of adopting LIBS as a fast, safe, less costly technique evaluating qualitatively the nutrients content of both maternal and commercial milk samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Laser-Induced Breakdown Spectroscopy (LIBS) in a Novel Molten Salt Aerosol System.

    Science.gov (United States)

    Williams, Ammon N; Phongikaroon, Supathorn

    2017-04-01

    In the pyrochemical separation of used nuclear fuel (UNF), fission product, rare earth, and actinide chlorides accumulate in the molten salt electrolyte over time. Measuring this salt composition in near real-time is advantageous for operational efficiency, material accountability, and nuclear safeguards. Laser-induced breakdown spectroscopy (LIBS) has been proposed and demonstrated as a potential analytical approach for molten LiCl-KCl salts. However, all the studies conducted to date have used a static surface approach which can lead to issues with splashing, low repeatability, and poor sample homogeneity. In this initial study, a novel molten salt aerosol approach has been developed and explored to measure the composition of the salt via LIBS. The functionality of the system has been demonstrated as well as a basic optimization of the laser energy and nebulizer gas pressure used. Initial results have shown that this molten salt aerosol-LIBS system has a great potential as an analytical technique for measuring the molten salt electrolyte used in this UNF reprocessing technology.

  1. Analysis of heterogeneous gallstones using laser-induced breakdown spectroscopy (LIBS) and wavelength dispersive X-ray fluorescence (WD-XRF).

    Science.gov (United States)

    Jaswal, Brij Bir S; Kumar, Vinay; Sharma, Jitendra; Rai, Pradeep K; Gondal, Mohammed A; Gondal, Bilal; Singh, Vivek K

    2016-04-01

    Laser-induced breakdown spectroscopy (LIBS) is an emerging analytical technique with numerous advantages such as rapidity, multi-elemental analysis, no specific sample preparation requirements, non-destructiveness, and versatility. It has been proven to be a robust elemental analysis tool attracting interest because of being applied to a wide range of materials including biomaterials. In this paper, we have performed spectroscopic studies on gallstones which are heterogeneous in nature using LIBS and wavelength dispersive X-ray fluorescence (WD-XRF) techniques. It has been observed that the presence and relative concentrations of trace elements in different kind of gallstones (cholesterol and pigment gallstones) can easily be determined using LIBS technique. From the experiments carried out on gallstones for trace elemental mapping and detection, it was found that LIBS is a robust tool for such biomedical applications. The stone samples studied in the present paper were classified using the Fourier transform infrared (FTIR) spectroscopy. WD-XRF spectroscopy has been applied for the qualitative and quantitative analysis of major and trace elements present in the gallstone which was compared with the LIBS data. The results obtained in the present paper show interesting prospects for LIBS and WD-XRF to study cholelithiasis better.

  2. A Simple Device for Lens-to-Sample Distance Adjustment in Laser-Induced Breakdown Spectroscopy (LIBS).

    Science.gov (United States)

    Cortez, Juliana; Farias Filho, Benedito B; Fontes, Laiane M; Pasquini, Celio; Raimundo, Ivo M; Pimentel, Maria Fernanda; de Souza Lins Borba, Flávia

    2017-04-01

    A simple device based on two commercial laser pointers is described to assist in the analysis of samples that present uneven surfaces and/or irregular shapes using laser-induced breakdown spectroscopy (LIBS). The device allows for easy positioning of the sample surface at a reproducible distance from the focusing lens that conveys the laser pulse to generate the micro-plasma in a LIBS system, with reproducibility better than ±0.2 mm. In this way, fluctuations in the fluence (J cm -2 ) are minimized and the LIBS analytical signals can be obtained with a better precision even when samples with irregular surfaces are probed.

  3. MEvoLib v1.0: the first molecular evolution library for Python.

    Science.gov (United States)

    Álvarez-Jarreta, Jorge; Ruiz-Pesini, Eduardo

    2016-10-28

    Molecular evolution studies involve many different hard computational problems solved, in most cases, with heuristic algorithms that provide a nearly optimal solution. Hence, diverse software tools exist for the different stages involved in a molecular evolution workflow. We present MEvoLib, the first molecular evolution library for Python, providing a framework to work with different tools and methods involved in the common tasks of molecular evolution workflows. In contrast with already existing bioinformatics libraries, MEvoLib is focused on the stages involved in molecular evolution studies, enclosing the set of tools with a common purpose in a single high-level interface with fast access to their frequent parameterizations. The gene clustering from partial or complete sequences has been improved with a new method that integrates accessible external information (e.g. GenBank's features data). Moreover, MEvoLib adjusts the fetching process from NCBI databases to optimize the download bandwidth usage. In addition, it has been implemented using parallelization techniques to cope with even large-case scenarios. MEvoLib is the first library for Python designed to facilitate molecular evolution researches both for expert and novel users. Its unique interface for each common task comprises several tools with their most used parameterizations. It has also included a method to take advantage of biological knowledge to improve the gene partition of sequence datasets. Additionally, its implementation incorporates parallelization techniques to enhance computational costs when handling very large input datasets.

  4. Multivariate analysis of remote LIBS spectra using partial least squares, principal component analysis, and related techniques

    Energy Technology Data Exchange (ETDEWEB)

    Clegg, Samuel M [Los Alamos National Laboratory; Barefield, James E [Los Alamos National Laboratory; Wiens, Roger C [Los Alamos National Laboratory; Sklute, Elizabeth [MT HOLYOKE COLLEGE; Dyare, Melinda D [MT HOLYOKE COLLEGE

    2008-01-01

    Quantitative analysis with LIBS traditionally employs calibration curves that are complicated by the chemical matrix effects. These chemical matrix effects influence the LIBS plasma and the ratio of elemental composition to elemental emission line intensity. Consequently, LIBS calibration typically requires a priori knowledge of the unknown, in order for a series of calibration standards similar to the unknown to be employed. In this paper, three new Multivariate Analysis (MV A) techniques are employed to analyze the LIBS spectra of 18 disparate igneous and highly-metamorphosed rock samples. Partial Least Squares (PLS) analysis is used to generate a calibration model from which unknown samples can be analyzed. Principal Components Analysis (PCA) and Soft Independent Modeling of Class Analogy (SIMCA) are employed to generate a model and predict the rock type of the samples. These MV A techniques appear to exploit the matrix effects associated with the chemistries of these 18 samples.

  5. Laser-induced breakdown spectroscopy (LIBS), part II: review of instrumental and methodological approaches to material analysis and applications to different fields.

    Science.gov (United States)

    Hahn, David W; Omenetto, Nicoló

    2012-04-01

    The first part of this two-part review focused on the fundamental and diagnostics aspects of laser-induced plasmas, only touching briefly upon concepts such as sensitivity and detection limits and largely omitting any discussion of the vast panorama of the practical applications of the technique. Clearly a true LIBS community has emerged, which promises to quicken the pace of LIBS developments, applications, and implementations. With this second part, a more applied flavor is taken, and its intended goal is summarizing the current state-of-the-art of analytical LIBS, providing a contemporary snapshot of LIBS applications, and highlighting new directions in laser-induced breakdown spectroscopy, such as novel approaches, instrumental developments, and advanced use of chemometric tools. More specifically, we discuss instrumental and analytical approaches (e.g., double- and multi-pulse LIBS to improve the sensitivity), calibration-free approaches, hyphenated approaches in which techniques such as Raman and fluorescence are coupled with LIBS to increase sensitivity and information power, resonantly enhanced LIBS approaches, signal processing and optimization (e.g., signal-to-noise analysis), and finally applications. An attempt is made to provide an updated view of the role played by LIBS in the various fields, with emphasis on applications considered to be unique. We finally try to assess where LIBS is going as an analytical field, where in our opinion it should go, and what should still be done for consolidating the technique as a mature method of chemical analysis. © 2012 Society for Applied Spectroscopy

  6. Raman/LIBS Data Fusion via Two-Way Variational Autoencoders

    Science.gov (United States)

    Parente, M.; Gemp, I.

    2018-04-01

    We propose an original solution to extracting mineral abundances from Raman spectra by combining Raman data with LIBS using a novel deep learning model based on variational autoencoders and data fusion, which outperforms the current state of the art.

  7. Secular Variation and Physical Characteristics Determination of the HADS Star EH Lib

    Science.gov (United States)

    Pena, J. H.; Villarreal, C.; Pina, D. S.; Renteria, A.; Soni, A., Guillen, J. Calderon, J.

    2017-12-01

    Physical parameters of EH Lib have been determined based on observations carried out in 2015 with photometry. They have also served, along with samples from the years 1969 and 1986, to analyse the frequency content of EH Lib with Fourier Transforms. Recent CCD observations increased the times of maximum with twelve new times which helped us study the secular variation of the period with a method based on the minimization of the standard deviation of the O-C residuals. It is concluded that there may be a long-term period change.

  8. Zlepšování limitů detekce spektroskopie laserem indukovaného plazmatu (LIBS) pomocí aplikace nanočástic

    OpenAIRE

    Képeš, Erik

    2014-01-01

    Bakalárska práca popisuje možnosti zlepšovania detekčných limít metódy spektroskopie laserom indukovanej plazmy (LIBS). Zhŕňa modifikácie klasickej aparatúry, ktoré využívajú metódy double-pulsed LIBS (DPLIBS), Townsend effect plasma sectroscopy (TEPS), resonance enhanced LIBS (RELIBS), spark discharge LIBS (SDLIBS), flame-enhanced LIBS (FELIBS) aj nové postupy pri príprave vzoriek, ktoré používa metóda nanoparticle enhanced LIBS (NELIBS). Popisuje mechanizmy, ktoré využívajú jednotlivé metód...

  9. A brief history of laser-induced breakdown spectroscopy: From the concept of atoms to LIBS 2012

    International Nuclear Information System (INIS)

    Radziemski, Leon; Cremers, David

    2013-01-01

    LIBS did not appear de novo in 1962, but was built upon accomplishments of the past. These started with very old concepts of indivisible units (atomos), chemical and physical experiments and theoretical advances that took place in the late 19th and early 20th centuries, the development of the laser, the discovery of gas breakdown, and the realization of the application to spectrochemistry. We sketch the historical developments and focus as well on the advances in LIBS methodology and instrumentation over the past 50 years, culminating with a synopsis of the LIBS 2012 Conference in Luxor, Egypt

  10. A brief history of laser-induced breakdown spectroscopy: From the concept of atoms to LIBS 2012

    Energy Technology Data Exchange (ETDEWEB)

    Radziemski, Leon, E-mail: ljrbwr@comcast.net [Tucson, AZ (United States); Cremers, David [Applied Research Associates Inc., Albuquerque, NM (United States)

    2013-09-01

    LIBS did not appear de novo in 1962, but was built upon accomplishments of the past. These started with very old concepts of indivisible units (atomos), chemical and physical experiments and theoretical advances that took place in the late 19th and early 20th centuries, the development of the laser, the discovery of gas breakdown, and the realization of the application to spectrochemistry. We sketch the historical developments and focus as well on the advances in LIBS methodology and instrumentation over the past 50 years, culminating with a synopsis of the LIBS 2012 Conference in Luxor, Egypt.

  11. Application of Handheld Laser-Induced Breakdown Spectroscopy (LIBS) to Geochemical Analysis.

    Science.gov (United States)

    Connors, Brendan; Somers, Andrew; Day, David

    2016-05-01

    While laser-induced breakdown spectroscopy (LIBS) has been in use for decades, only within the last two years has technology progressed to the point of enabling true handheld, self-contained instruments. Several instruments are now commercially available with a range of capabilities and features. In this paper, the SciAps Z-500 handheld LIBS instrument functionality and sub-systems are reviewed. Several assayed geochemical sample sets, including igneous rocks and soils, are investigated. Calibration data are presented for multiple elements of interest along with examples of elemental mapping in heterogeneous samples. Sample preparation and the data collection method from multiple locations and data analysis are discussed. © The Author(s) 2016.

  12. Evaluation of the efficacy of a portable LIBS system for detection of CWA on surfaces.

    Science.gov (United States)

    L'Hermite, D; Vors, E; Vercouter, T; Moutiers, G

    2016-05-01

    Laser-induced breakdown spectroscopy (LIBS) is a laser-based optical technique particularly suited for in situ surface analysis. A portable LIBS instrument was tested to detect surface chemical contamination by chemical warfare agents (CWAs). Test of detection of surface contamination was carried out in a toxlab facility with four CWAs, sarin (GB), lewisite (L1), mustard gas (HD), and VX, which were deposited on different substrates, wood, concrete, military green paint, gloves, and ceramic. The CWAs were detected by means of the detection of atomic markers (As, P, F, Cl, and S). The LIBS instrument can give a direct response in terms of detection thanks to an integrated interface for non-expert users or so called end-users. We have evaluated the capability of automatic detection of the selected CWAs. The sensitivity of our portable LIBS instrument was confirmed for the detection of a CWA at surface concentrations above 15 μg/cm(2). The simultaneous detection of two markers may lead to a decrease of the number of false positive.

  13. Remote quantitative analysis of minerals based on multispectral line-calibrated laser-induced breakdown spectroscopy (LIBS).

    Science.gov (United States)

    Wan, Xiong; Wang, Peng

    2014-01-01

    Laser-induced breakdown spectroscopy (LIBS) is a feasible remote sensing technique used for mineral analysis in some unapproachable places where in situ probing is needed, such as analysis of radioactive elements in a nuclear leak or the detection of elemental compositions and contents of minerals on planetary and lunar surfaces. Here a compact custom 15 m focus optical component, combining a six times beam expander with a telescope, has been built, with which the laser beam of a 1064 nm Nd ; YAG laser is focused on remote minerals. The excited LIBS signals that reveal the elemental compositions of minerals are collected by another compact single lens-based signal acquisition system. In our remote LIBS investigations, the LIBS spectra of an unknown ore have been detected, from which the metal compositions are obtained. In addition, a multi-spectral line calibration (MSLC) method is proposed for the quantitative analysis of elements. The feasibility of the MSLC and its superiority over a single-wavelength determination have been confirmed by comparison with traditional chemical analysis of the copper content in the ore.

  14. Identification of offal adulteration in beef by laser induced breakdown spectroscopy (LIBS).

    Science.gov (United States)

    Velioglu, Hasan Murat; Sezer, Banu; Bilge, Gonca; Baytur, Süleyman Efe; Boyaci, Ismail Hakki

    2018-04-01

    Minced meat is the major ingredient in sausages, beef burgers, and similar products; and thus it is the main product subjected to adulteration with meat offal. Determination of this kind of meat adulteration is crucial due to religious, economic and ethical concerns. The aim of the present study is to discriminate the beef meat and offal samples by using laser induced breakdown spectroscopy (LIBS). To this end, LIBS and multivariate data analysis were used to discriminate pure beef and offal samples qualitatively and to determine the offal mixture adulteration quantitatively. In this analysis, meat samples were frozen and LIBS analysis were performed. The results indicate that by using principal component analysis (PCA), discrimination of pure offal and offal mixture adulterated beef samples can be achieved successfully. Besides, adulteration ratio can be determined using partial least square analysis method (PLS) with 0.947 coefficient of determination (R 2 ) and 3.8% of limit of detection (LOD) values for offal mixture adulterated beef samples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Mid-infrared, long wave infrared (4-12 μm) molecular emission signatures from pharmaceuticals using laser-induced breakdown spectroscopy (LIBS).

    Science.gov (United States)

    Yang, Clayton S-C; Brown, Ei E; Kumi-Barimah, Eric; Hommerich, Uwe H; Jin, Feng; Trivedi, Sudhir B; Samuels, Alan C; Snyder, A Peter

    2014-01-01

    In an effort to augment the atomic emission spectra of conventional laser-induced breakdown spectroscopy (LIBS) and to provide an increase in selectivity, mid-wave to long-wave infrared (IR), LIBS studies were performed on several organic pharmaceuticals. Laser-induced breakdown spectroscopy signature molecular emissions of target organic compounds are observed for the first time in the IR fingerprint spectral region between 4-12 μm. The IR emission spectra of select organic pharmaceuticals closely correlate with their respective standard Fourier transform infrared spectra. Intact and/or fragment sample molecular species evidently survive the LIBS event. The combination of atomic emission signatures derived from conventional ultraviolet-visible-near-infrared LIBS with fingerprints of intact molecular entities determined from IR LIBS promises to be a powerful tool for chemical detection.

  16. Návrh posuvu fokusačního objektivu uvnitř interakční komory LIBS aparatury

    OpenAIRE

    Olejník, Ivan

    2008-01-01

    Diplomová práca popisuje návrh posuvu fokusačného objektívu vo vnútri interakčnej komory LIBS. Obsahuje popis základných vlastností a funkcií LIBS spektroskopie. Opisuje prehžad použitežných komponentov, hodnotí ich vlastnosti a vhodnosť použitia v konštrukcii posuvu do vákua. Ďalej uvádza výsledné konštrukčné riešenie lineárneho posuvu do vákua a hodnotí jeho výhody pre metódu LIBS. This diploma thesis describes the design of a translation stage for focusing objective inside the LIBS inte...

  17. Loading of deuterium and helium by Pilot-PSI plasma and their detection by in-situ LIBS

    NARCIS (Netherlands)

    Piip, K.; van der Meiden, H. J.; Bystrov, K.; Hämarik, L.; Karhunen, J.; Aints, M.; Laan, M.; Paris, P.; Seemen, H.; Hakola, A.; Brezinsek, S.

    2017-01-01

    Laser-induced breakdown spectroscopy (LIBS) is a promising method for quantifying the fuel content of the plasma-facing components of ITER both in between plasma discharges (in-situ) and after maintenance operations. The aim of the present study is to test the applicability of in-situ LIBS for

  18. EggLib: processing, analysis and simulation tools for population genetics and genomics

    Directory of Open Access Journals (Sweden)

    De Mita Stéphane

    2012-04-01

    Full Text Available Abstract Background With the considerable growth of available nucleotide sequence data over the last decade, integrated and flexible analytical tools have become a necessity. In particular, in the field of population genetics, there is a strong need for automated and reliable procedures to conduct repeatable and rapid polymorphism analyses, coalescent simulations, data manipulation and estimation of demographic parameters under a variety of scenarios. Results In this context, we present EggLib (Evolutionary Genetics and Genomics Library, a flexible and powerful C++/Python software package providing efficient and easy to use computational tools for sequence data management and extensive population genetic analyses on nucleotide sequence data. EggLib is a multifaceted project involving several integrated modules: an underlying computationally efficient C++ library (which can be used independently in pure C++ applications; two C++ programs; a Python package providing, among other features, a high level Python interface to the C++ library; and the egglib script which provides direct access to pre-programmed Python applications. Conclusions EggLib has been designed aiming to be both efficient and easy to use. A wide array of methods are implemented, including file format conversion, sequence alignment edition, coalescent simulations, neutrality tests and estimation of demographic parameters by Approximate Bayesian Computation (ABC. Classes implementing different demographic scenarios for ABC analyses can easily be developed by the user and included to the package. EggLib source code is distributed freely under the GNU General Public License (GPL from its website http://egglib.sourceforge.net/ where a full documentation and a manual can also be found and downloaded.

  19. EggLib: processing, analysis and simulation tools for population genetics and genomics.

    Science.gov (United States)

    De Mita, Stéphane; Siol, Mathieu

    2012-04-11

    With the considerable growth of available nucleotide sequence data over the last decade, integrated and flexible analytical tools have become a necessity. In particular, in the field of population genetics, there is a strong need for automated and reliable procedures to conduct repeatable and rapid polymorphism analyses, coalescent simulations, data manipulation and estimation of demographic parameters under a variety of scenarios. In this context, we present EggLib (Evolutionary Genetics and Genomics Library), a flexible and powerful C++/Python software package providing efficient and easy to use computational tools for sequence data management and extensive population genetic analyses on nucleotide sequence data. EggLib is a multifaceted project involving several integrated modules: an underlying computationally efficient C++ library (which can be used independently in pure C++ applications); two C++ programs; a Python package providing, among other features, a high level Python interface to the C++ library; and the egglib script which provides direct access to pre-programmed Python applications. EggLib has been designed aiming to be both efficient and easy to use. A wide array of methods are implemented, including file format conversion, sequence alignment edition, coalescent simulations, neutrality tests and estimation of demographic parameters by Approximate Bayesian Computation (ABC). Classes implementing different demographic scenarios for ABC analyses can easily be developed by the user and included to the package. EggLib source code is distributed freely under the GNU General Public License (GPL) from its website http://egglib.sourceforge.net/ where a full documentation and a manual can also be found and downloaded.

  20. Studies of Basalt Through Laser Induced Breakdown Spectroscopy (LIBS for the Manufacturing of Lapilli Blocks

    Directory of Open Access Journals (Sweden)

    Ismael De la Viuda-Pérez

    2016-10-01

    Full Text Available Basaltic samples selected from different areas of Tenerife were analyzed by applying laser induced breakdown spectroscopy (LIBS, Raman spectroscopy and X Ray Diffraction (XRD in order to identify the basic chemical composition and mineralogy. The basic composition obtained from the analysis was: O, F, Na, K, Mg, Al Si, Ca, Ti and Fe. Raman spectroscopic and XRD analyses indicated a basaltic mineralogy which is consistent with the basic composition results obtained from LIBS. The results of the analyses carried out using portable instrumentation proved the suitability of the LIBS, specially combined with the Raman spectroscopy for their application in the mineralogical-chemical identification in the areas where basalts and lapilli are extracted for construction works in Tenerife.

  1. An Exploratory study on the use of LibAnswers to Resolve, Track and Monitor Electronic Resources Issues: The KAUST Library experience

    KAUST Repository

    Ramli, Rindra M.

    2017-01-01

    An Exploratory study on KAUST library use of LibAnswers in resolving electronic resources questions received in LibAnswers. It describes the findings of the questions received in LibAnswers. The author made suggestions based on the findings to improve the reference services in responding to e-resources questions.

  2. An Exploratory study on the use of LibAnswers to Resolve, Track and Monitor Electronic Resources Issues: The KAUST Library experience

    KAUST Repository

    Ramli, Rindra M.

    2017-05-03

    An Exploratory study on KAUST library use of LibAnswers in resolving electronic resources questions received in LibAnswers. It describes the findings of the questions received in LibAnswers. The author made suggestions based on the findings to improve the reference services in responding to e-resources questions.

  3. Improved intact soil-core carbon determination applying regression shrinkage and variable selection techniques to complete spectrum laser-induced breakdown spectroscopy (LIBS).

    Science.gov (United States)

    Bricklemyer, Ross S; Brown, David J; Turk, Philip J; Clegg, Sam M

    2013-10-01

    Laser-induced breakdown spectroscopy (LIBS) provides a potential method for rapid, in situ soil C measurement. In previous research on the application of LIBS to intact soil cores, we hypothesized that ultraviolet (UV) spectrum LIBS (200-300 nm) might not provide sufficient elemental information to reliably discriminate between soil organic C (SOC) and inorganic C (IC). In this study, using a custom complete spectrum (245-925 nm) core-scanning LIBS instrument, we analyzed 60 intact soil cores from six wheat fields. Predictive multi-response partial least squares (PLS2) models using full and reduced spectrum LIBS were compared for directly determining soil total C (TC), IC, and SOC. Two regression shrinkage and variable selection approaches, the least absolute shrinkage and selection operator (LASSO) and sparse multivariate regression with covariance estimation (MRCE), were tested for soil C predictions and the identification of wavelengths important for soil C prediction. Using complete spectrum LIBS for PLS2 modeling reduced the calibration standard error of prediction (SEP) 15 and 19% for TC and IC, respectively, compared to UV spectrum LIBS. The LASSO and MRCE approaches provided significantly improved calibration accuracy and reduced SEP 32-55% over UV spectrum PLS2 models. We conclude that (1) complete spectrum LIBS is superior to UV spectrum LIBS for predicting soil C for intact soil cores without pretreatment; (2) LASSO and MRCE approaches provide improved calibration prediction accuracy over PLS2 but require additional testing with increased soil and target analyte diversity; and (3) measurement errors associated with analyzing intact cores (e.g., sample density and surface roughness) require further study and quantification.

  4. Development of laser-based technology for the routine first wall diagnostic on the tokamak EAST: LIBS and LIAS

    Science.gov (United States)

    Hu, Z.; Gierse, N.; Li, C.; Liu, P.; Zhao, D.; Sun, L.; Oelmann, J.; Nicolai, D.; Wu, D.; Wu, J.; Mao, H.; Ding, F.; Brezinsek, S.; Liang, Y.; Ding, H.; Luo, G.; Linsmeier, C.; EAST Team

    2017-12-01

    A laser based method combined with spectroscopy, such as laser-induced breakdown spectroscopy (LIBS) and laser-induced ablation spectroscopy (LIAS), is a promising technology for plasma-wall interaction studies. In this work, we report the development of in situ laser-based diagnostics (LIBS and LIAS) for the assessment of static and dynamic fuel retention on the first wall without removing the tiles between and during plasma discharges in the Experimental Advanced Superconducting Tokamak (EAST). The fuel retention on the first wall was measured after different wall conditioning methods and daily plasma discharges by in situ LIBS. The result indicates that the LIBS can be a useful tool to predict the wall condition in EAST. With the successful commissioning of a refined timing system for LIAS, an in situ approach to investigate fuel retention is proposed.

  5. Temperature and Electron Density Determination on Laser-Induced Breakdown Spectroscopy (LIBS) Plasmas: A Physical Chemistry Experiment

    Science.gov (United States)

    Najarian, Maya L.; Chinni, Rosemarie C.

    2013-01-01

    This laboratory is designed for physical chemistry students to gain experience using laser-induced breakdown spectroscopy (LIBS) in understanding plasma diagnostics. LIBS uses a high-powered laser that is focused on the sample causing a plasma to form. The emission of this plasma is then spectrally resolved and detected. Temperature and electron…

  6. Występowanie szarej pleśni tulipanow – Botrytis tulipae (Lib. Lind na plantacjach produkcyjnych [Botrytis tulipae (Lib. Lind in tulip plantations

    Directory of Open Access Journals (Sweden)

    Cz. Zamorski

    2015-06-01

    Full Text Available The incidence of disease caused by Botrytis tulipae (Lib. Lind was studied in selected tulip plantations. Primary and secondary infection, as well as infections of daughter bulbs were observed. The number of affected plants differed according (to the variety, season, and rainfall.

  7. Homogeneity testing and quantitative analysis of manganese (Mn in vitrified Mn-doped glasses by laser-induced breakdown spectroscopy (LIBS

    Directory of Open Access Journals (Sweden)

    V. K. Unnikrishnan

    2014-09-01

    Full Text Available Laser-induced breakdown spectroscopy (LIBS, an atomic emission spectroscopy method, has rapidly grown as one of the best elemental analysis techniques over the past two decades. Homogeneity testing and quantitative analysis of manganese (Mn in manganese-doped glasses have been carried out using an optimized LIBS system employing a nanosecond ultraviolet Nd:YAG laser as the source of excitation. The glass samples have been prepared using conventional vitrification methods. The laser pulse irradiance on the surface of the glass samples placed in air at atmospheric pressure was about 1.7×109 W/cm2. The spatially integrated plasma emission was collected and imaged on to the spectrograph slit using an optical-fiber-based collection system. Homogeneity was checked by recording LIBS spectra from different sites on the sample surface and analyzing the elemental emission intensities for concentration determination. Validation of the observed LIBS results was done by comparison with scanning electron microscope- energy dispersive X-ray spectroscopy (SEM-EDX surface elemental mapping. The analytical performance of the LIBS system has been evaluated through the correlation of the LIBS determined concentrations of Mn with its certified values. The results are found to be in very good agreement with the certified concentrations.

  8. Monitoring of Cr, Cu, Pb, V and Zn in polluted soils by laser induced breakdown spectroscopy (LIBS).

    Science.gov (United States)

    Dell'Aglio, Marcella; Gaudiuso, Rosalba; Senesi, Giorgio S; De Giacomo, Alessandro; Zaccone, Claudio; Miano, Teodoro M; De Pascale, Olga

    2011-05-01

    Laser Induced Breakdown Spectroscopy (LIBS) is a fast and multi-elemental analytical technique particularly suitable for the qualitative and quantitative analysis of heavy metals in solid samples, including environmental ones. Although LIBS is often recognised in the literature as a well-established analytical technique, results about quantitative analysis of elements in chemically complex matrices such as soils are quite contrasting. In this work, soil samples of various origins have been analyzed by LIBS and data compared to those obtained by Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES). The emission intensities of one selected line for each of the five analytes (i.e., Cr, Cu, Pb, V, and Zn) were normalized to the background signal, and plotted as a function of the concentration values previously determined by ICP-OES. Data showed a good linearity for all calibration lines drawn, and the correlation between ICP-OES and LIBS was confirmed by the satisfactory agreement obtained between the corresponding values. Consequently, LIBS method can be used at least for metal monitoring in soils. In this respect, a simple method for the estimation of the soil pollution degree by heavy metals, based on the determination of an anthropogenic index, was proposed and determined for Cr and Zn.

  9. Laser-induced breakdown spectroscopy (LIBS): a new spectrochemical technique

    International Nuclear Information System (INIS)

    Radziemski, L.J.; Loree, T.R.; Cremers, D.A.

    1982-01-01

    We have used the breakdown spark from a focused laser beam to generate analytically useful emission spectra of minor constituents in air and other carrier gases. The medium was sampled directly. It was not necessary to reduce the sample to solution nor to introduce electrodes. The apparatus is particularly simple; a pulsed laser, spectrometer, and some method for time resolution. The latter is essential in laser-induced-breakdown spectroscopy (LIBS) because of the strong early continuum. High temperatures in the spark result in vaporization of small particles, dissociation of molecules, and excitation of atomic and ionic spectra, including species which are normally difficult to detect. In one application, we have monitored beryllium in air at conventrations below 1 μg/m 3 , which is below 1 ppB (w/w). In another we have monitored chlorine and fluorine atoms in real time. LIBS has the potential for real-time direct sampling of contaminants in situ

  10. [Effect of Characteristic Variable Extraction on Accuracy of Cu in Navel Orange Peel by LIBS].

    Science.gov (United States)

    Li, Wen-bing; Yao, Ming-yin; Huang, Lin; Chen, Tian-bing; Zheng, Jian-hong; Fan, Shi-quan; Liu Mu-hua HE, Mu-hua; Lin, Jin-long; Ouyang, Jing-yi

    2015-07-01

    Heavy metals pollution in foodstuffs is more and more serious. It is impossible to satisfy the modern agricultural development by conventional chemical analysis. Laser induced breakdown spectroscopy (LIBS) is an emerging technology with the characteristic of rapid and nondestructive detection. But LIBS' s repeatability, sensitivity and accuracy has much room to improve. In this work, heavy metal Cu in Gannan Navel Orange which is the Jiangxi specialty fruit will be predicted by LIBS. Firstly, the navel orange samples were contaminated in our lab. The spectra of samples were collected by irradiating the peel by optimized LIBS parameters. The laser energy was set as 20 mJ, delay time of Spectral Data Gathering was set as 1.2 micros, the integration time of Spectral data gathering was set as 2 ms. The real concentration in samples was obtained by AAS (atom absorption spectroscopy). The characteristic variables Cu I 324.7 and Cu I 327.4 were extracted. And the calibration model was constructed between LIBS spectra and real concentration about Cu. The results show that relative error of the predicted concentrations of three relational model were 7.01% or less, reached a minimum of 0.02%, 0.01% and 0.02% respectively. The average relative errors were 2.33%, 3.10% and 26.3%. Tests showed that different characteristic variables decided different accuracy. It is very important to choose suitable characteristic variable. At the same time, this work is helpful to explore the distribution of heavy metals between pulp and peel.

  11. Simulated In Situ Determination of Soil Profile Organic and Inorganic Carbon With LIBS and VisNIR

    Science.gov (United States)

    Bricklemyer, R. S.; Brown, D. J.; Clegg, S. M.; Barefield, J. E.

    2008-12-01

    There is growing need for rapid, accurate, and inexpensive methods to measure, and verify soil organic carbon (SOC) change for national greenhouse gas accounting and the development of a soil carbon trading market. Laser Induced Breakdown Spectroscopy (LIBS) and Visible and Near Infrared Spectroscopy (VisNIR) are complementary analytical techniques that have the potential to fill that need. The LIBS method provides precise elemental analysis of soils, but generally cannot distinguish between organic C and inorganic C. VisNIR has been established as a viable technique for measuring soil properties including SOC and inorganic carbon (IC). As part of the Big Sky Carbon Sequestration Regional Partnership, 240 intact core samples (3.8 x 50 cm) have been collected from six agricultural fields in north central Montana, USA. Each of these core samples were probed concurrently with LIBS and VisNIR at 2.5, 7.5, 12.5, 17.5, 22.5, 27.5, 35 and 45 cm (+/- 1.5 cm) depths. VisNIR measurements were taken using an Analytical Spectral Devices (ASD, Boulder, CO, USA) Agrispec spectrometer to determine the partition of SOC vs. IC in the samples. The LIBS scans were collected with the LANL LIBS Core Scanner Instrument which collected the entire 200 - 900 nm plasma emission including the 247.8 nm carbon emission line. This instrument also collected the emission from the elements typically found in inorganic carbon (Ca and Mg) and organic carbon (H, O, and N). Subsamples of soil (~ 4 g) were taken from interrogation points for laboratory determination of SOC and IC. Using this analytical data, we constructed several full spectrum multivariate VisNIR/LIBS calibration models for SOC and IC. These models were then applied to independent validation cores for model evaluation.

  12. Multi-Pulse Excitation for Underwater Analysis of Copper-Based Alloys Using a Novel Remote Laser-Induced Breakdown Spectroscopy (LIBS) System.

    Science.gov (United States)

    Guirado, Salvador; Fortes, Francisco J; Laserna, J Javier

    2016-04-01

    In this work, the use of multi-pulse excitation has been evaluated as an effective solution to mitigate the preferential ablation of the most volatile elements, namely Sn, Pb, and Zn, observed during laser-induced breakdown spectroscopy (LIBS) analysis of copper-based alloys. The novel remote LIBS prototype used in this experiments featured both single-pulse (SP-LIBS) and multi-pulse excitation (MP-LIBS). The remote instrument is capable of performing chemical analysis of submersed materials up to a depth of 50 m. Laser-induced breakdown spectroscopy analysis was performed at air pressure settings simulating the conditions during a real subsea analysis. A set of five certified bronze standards with variable concentration of Cu, As, Sn, Pb, and Zn were used. In SP-LIBS, signal emission is strongly sensitive to ambient pressure. In this case, fractionation effect was observed. Multi-pulse excitation circumvents the effect of pressure over the quantitative analysis, thus avoiding the fractionation phenomena observed in single pulse LIBS. The use of copper as internal standard minimizes matrix effects and discrepancies due to variation in ablated mass. © The Author(s) 2016.

  13. [Determination of Cu in Shell of Preserved Egg by LIBS Coupled with PLS].

    Science.gov (United States)

    Hu, Hui-qin; Xu, Xue-hong; Liu, Mu-hua; Tu, Jian-ping; Huang, Le; Huang, Lin; Yao, Ming-yin; Chen, Tian-bing; Yang, Ping

    2015-12-01

    In this work, the content of copper in the shell of preserved eggs were determined directly by Laser induced breakdown spectroscopy (LIBS), and the characteristics lines of Cu was obtained. The samples of eggshell were pretreated by acid wet digestion, and the real content of Cu was obtained by atomic absorption spectrophotometer (AAS). Due to the test precision and accuracy of LIBS was influenced by a serious of factors, for example, the complex matrix effect of sample, the enviro nment noise, the system noise of the instrument, the stability of laser energy and so on. And the conventional unvariate linear calibration curve between LIBS intensity and content of element of sample, such as by use of Schiebe G-Lomakin equation, can not meet the requirement of quantitative analysis. In account of that, a kind of multivariate calibration method is needed. In this work, the data of LIBS spectra were processed by partial least squares (PLS), the precision and accuracy of PLS model were compared by different smoothing treatment and five pretreatment methods. The result showed that the correlation coefficient and the accuracy of the PLS model were improved, and the root mean square error and the average relative error were reduced effectively by 11 point smoothing with Multiplicative scatter correction (MSC) pretreatment. The results of the study show that, heavy metal Cu in preserved egg shells can be direct detected accurately by laser induced breakdown spectroscopy, and the next step batch tests will been conducted to find out the relationship of heavy metal Cu content in the preserved egg between the eggshell, egg white and egg yolk. And the goal of the contents of heavy metals in the egg white, egg yolk can be knew through determinate the eggshell by the LIBS can be achieved, to provide new method for rapid non-destructive testing technology for quality and satety of agricultural products.

  14. Physical and Chemical Barriers in Root Tissues Contribute to Quantitative Resistance to Fusarium oxysporum f. sp. pisi in Pea

    Directory of Open Access Journals (Sweden)

    Moustafa Bani

    2018-02-01

    Full Text Available Fusarium wilt caused by Fusarium oxysporum f. sp. pisi (Fop is one of the most destructive diseases of pea worldwide. Control of this disease is difficult and it is mainly based on the use of resistant cultivars. While monogenic resistance has been successfully used in the field, it is at risk of breakdown by the constant evolution of the pathogen. New sources of quantitative resistance have been recently identified from a wild relative Pisum spp. collection. Here, we characterize histologically the resistance mechanisms occurring in these sources of quantitative resistance. Detailed comparison, of the reaction at cellular level, of eight pea accessions with differential responses to Fop race 2, showed that resistant accessions established several barriers at the epidermis, exodermis, cortex, endodermis and vascular stele efficiently impeding fungal progression. The main components of these different barriers were carbohydrates and phenolic compounds including lignin. We found that these barriers were mainly based on three defense mechanisms including cell wall strengthening, formation of papilla-like structures at penetration sites and accumulation of different substances within and between cells. These defense reactions varied in intensity and localization between resistant accessions. Our results also clarify some steps of the infection process of F. oxysporum in plant and support the important role of cell wall-degrading enzymes in F. oxysporum pathogenicity.

  15. Evaluation of Optical Depths and Self-Absorption of Strontium and Aluminum Emission Lines in Laser-Induced Breakdown Spectroscopy (LIBS).

    Science.gov (United States)

    Alfarraj, Bader A; Bhatt, Chet R; Yueh, Fang Yu; Singh, Jagdish P

    2017-04-01

    Laser-induced breakdown spectroscopy (LIBS) is a widely used laser spectroscopic technique in various fields, such as material science, forensic science, biological science, and the chemical and pharmaceutical industries. In most LIBS work, the analysis is performed using radiative transitions from atomic emissions. In this study, the plasma temperature and the product [Formula: see text] (the number density N and the absorption path length [Formula: see text]) were determined to evaluate the optical depths and the self-absorption of Sr and Al lines. A binary mixture of strontium nitrate and aluminum oxide was used as a sample, consisting of variety of different concentrations in powder form. Laser-induced breakdown spectroscopy spectra were collected by varying various parameters, such as laser energy, gate delay time, and gate width time to optimize the LIBS signals. Atomic emission from Sr and Al lines, as observed in the LIBS spectra of different sample compositions, was used to characterize the laser induced plasma and evaluate the optical depths and self-absorption of LIBS.

  16. Contestation internationale contre élites mondiales : l’action directe et la politique délibérative sont-elles conciliables ?

    Directory of Open Access Journals (Sweden)

    Francis Dupuis-Déri

    2012-04-01

    Full Text Available Dans cet article, j’analyse à la lumière des normes libérales de la politique délibérative le bien-fondé de l’action directe contre les institutions internationales associées au néolibéralisme et à la mondialisation du capitalisme (Banque mondiale, Organisation mondiale du commerce, etc.. Le processus délibératif de ces organismes étant illégitime du point de vue de la théorie de la politique délibérative, les activistes du mouvement altermondialiste sont en droit de contester ces organismes. De plus, une attitude de contestation peut avoir en elle-même une valeur délibérative pour au moins sept raisons : (1 lancer une délibération ; (2 élargir la participation à la délibération ; (3 renforcer la représentativité ; (4 faire circuler l’information et faire connaître les arguments (publicité ; (5 stimuler l’imagination ; (6 pousser à l’action ; (7 relancer la délibération. Finalement, les mouvements sociaux tels que le mouvement altermondialiste peuvent être vus comme des forums délibératifs. Ainsi, qui veut évaluer la légitimité de l’action directe doit prendre en considération la nature délibérative du processus par lequel les activistes choisissent les moyens les plus efficaces à utiliser pour corriger les défauts du processus délibératif officiel et pour faire avancer l’égalité, la liberté et la justice.In this article I examine the legitimacy of direct action in relation to liberal deliberative norms and global institutions (World Bank, World Trade Organization, etc.. Since the deliberative processes of these institutions are illegitimate according to the theory of deliberative politics, the activists of the movement for global justice should be legitimate to confront these institutions. Moreover, confrontational action in itself may have a deliberative value for at least seven reasons: (1 initiating deliberation (agenda-setting ; (2 enlarging participation ; (3 enlarging

  17. Forensic Discrimination of Latent Fingerprints Using Laser-Induced Breakdown Spectroscopy (LIBS) and Chemometric Approaches.

    Science.gov (United States)

    Yang, Jun-Ho; Yoh, Jack J

    2018-01-01

    A novel technique is reported for separating overlapping latent fingerprints using chemometric approaches that combine laser-induced breakdown spectroscopy (LIBS) and multivariate analysis. The LIBS technique provides the capability of real time analysis and high frequency scanning as well as the data regarding the chemical composition of overlapping latent fingerprints. These spectra offer valuable information for the classification and reconstruction of overlapping latent fingerprints by implementing appropriate statistical multivariate analysis. The current study employs principal component analysis and partial least square methods for the classification of latent fingerprints from the LIBS spectra. This technique was successfully demonstrated through a classification study of four distinct latent fingerprints using classification methods such as soft independent modeling of class analogy (SIMCA) and partial least squares discriminant analysis (PLS-DA). The novel method yielded an accuracy of more than 85% and was proven to be sufficiently robust. Furthermore, through laser scanning analysis at a spatial interval of 125 µm, the overlapping fingerprints were reconstructed as separate two-dimensional forms.

  18. Advanced recognition of explosives in traces on polymer surfaces using LIBS and supervised learning classifiers.

    Science.gov (United States)

    Serrano, Jorge; Moros, Javier; Sánchez, Carlos; Macías, Jorge; Laserna, J Javier

    2014-01-02

    The large similarity existing in the spectral emissions collected from organic compounds by laser-induced breakdown spectroscopy (LIBS) is a limiting factor for the use of this technology in the real world. Specifically, among the most ambitious challenges of today's LIBS involves the recognition of an organic residue when neglected on the surface of an object of identical nature. Under these circumstances, the development of an efficient algorithm to disclose the minute differences within this highly complex spectral information is crucial for a realistic application of LIBS in countering explosive threats. An approach cemented on scatter plots of characteristic emission features has been developed to identify organic explosives when located on polymeric surfaces (teflon, nylon and polyethylene). By using selected spectral variables, the approach allows to design a concise classifier for alerting when one of four explosives (DNT, TNT, RDX and PETN) is present on the surface of the polymer. Ordinary products (butter, fuel oil, hand cream, olive oil and motor oil) cause no confusion in the decisions taken by the classifier. With rates of false negatives and false positives below 5%, results demonstrate that the classification algorithm enables to label residues according to their harmful nature in the most demanding scenario for a LIBS sensor. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. An exploratory study of the potential of LIBS for visualizing gunshot residue patterns.

    Science.gov (United States)

    López-López, María; Alvarez-Llamas, César; Pisonero, Jorge; García-Ruiz, Carmen; Bordel, Nerea

    2017-04-01

    The study of gunshot residue (GSR) patterns can assist in the reconstruction of shooting incidences. Currently, there is a real need of methods capable of furnishing simultaneous elemental analysis with higher specificity for the GSR pattern visualization. Laser-Induced Breakdown Spectroscopy (LIBS) provides a multi-elemental analysis of the sample, requiring very small amounts of material and no sample preparation. Due to these advantages, this study aims at exploring the potential of LIBS imaging for the visualization of GSR patterns. After the spectral characterization of individual GSR particles, the distribution of Pb, Sb and Ba over clothing targets, shot from different distances, were measured in laser raster mode. In particular, an array of spots evenly spaced at 800μm, using a stage displacement velocity of 4mm/s and a laser frequency of 5Hz was employed (e.g. an area of 130×165mm 2 was measured in less than 3h). A LIBS set-up based on the simultaneous use of two spectrographs with iCCD cameras and a motorized stage was used. This set-up allows obtaining information from two different wavelength regions (258-289 and 446-463nm) from the same laser induced plasma, enabling the simultaneous detection of the three characteristic elements (Pb, Sb, and Ba) of GSR particles from conventional ammunitions. The ability to visualize the 2D distribution GSR pattern by LIBS may have an important application in the forensic field, especially for the ballistics area. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Rapid Analysis of Ash Composition Using Laser-Induced Breakdown Spectroscopy (LIBS)

    Energy Technology Data Exchange (ETDEWEB)

    Tyler L. Westover

    2013-01-01

    Inorganic compounds are known to be problematic in the thermochemical conversion of biomass to syngas and ultimately hydrocarbon fuels. The elements Si, K, Ca, Na, S, P, Cl, Mg, Fe, and Al are particularly problematic and are known to influence reaction pathways, contribute to fouling and corrosion, poison catalysts, and impact waste streams. Substantial quantities of inorganic species can be entrained in the bark of trees during harvest operations. Herbaceous feedstocks often have even greater quantities of inorganic constituents, which can account for as much as one-fifth of the total dry matter. Current methodologies to measure the concentrations of these elements, such as inductively coupled plasma-optical emission spectrometry/mass spectrometry (ICP-OES/MS) are expensive in time and reagents. This study demonstrates that a new methodology employing laser-induced breakdown spectroscopy (LIBS) can rapidly and accurately analyze the inorganic constituents in a wide range of biomass materials, including both woody and herbaceous examples. This technique requires little or no sample preparation, does not consume any reagents, and the analytical data is available immediately. In addition to comparing LIBS data with the results from ICP-OES methods, this work also includes discussions of sample preparation techniques, calibration curves for interpreting LIBS spectra, minimum detection limits, and the use of internal standards and standard reference materials.

  1. Study of atomic and molecular emission spectra of Sr by laser induced breakdown spectroscopy (LIBS).

    Science.gov (United States)

    Bhatt, Chet R; Alfarraj, Bader; Ayyalasomayajula, Krishna K; Ghany, Charles; Yueh, Fang Y; Singh, Jagdish P

    2015-12-01

    Laser Induced Breakdown Spectroscopy (LIBS) is an ideal analytical technique for in situ analysis of elemental composition. We have performed a comparative study of the quantitative and qualitative analysis of atomic and molecular emission from LIBS spectra. In our experiments, a mixture of SrCl2 and Al2O3 in powder form was used as a sample. The atomic emission from Sr and molecular emission from SrCl and SrO observed in LIBS spectra were analyzed. The optimum laser energies, gate delays, and gate widths for selected atomic lines and molecular bands were determined from spectra recorded at various experimental parameters. These optimum experimental conditions were used to collect calibration data, and the calibration curves were used to predict the Sr concentration. Limits of detection (LODs) for selected atomic and molecular emission spectra were determined.

  2. Standoff Laser-Induced Breakdown Spectroscopy (LIBS) Using a Miniature Wide Field of View Spatial Heterodyne Spectrometer with Sub-Microsteradian Collection Optics.

    Science.gov (United States)

    Barnett, Patrick D; Lamsal, Nirmal; Angel, S Michael

    2017-04-01

    A spatial heterodyne spectrometer (SHS) is described for standoff laser-induced breakdown spectroscopy (LIBS) measurements. The spatial heterodyne LIBS spectrometer (SHLS) is a diffraction grating based interferometer with no moving parts that offers a very large field of view, high light throughput, and high spectral resolution in a small package. The field of view of the SHLS spectrometer is shown to be ∼1° in standoff LIBS measurements. In the SHLS system described here, the collection aperture was defined by the 10 mm diffraction gratings in the SHS and standoff LIBS measurements were made up to 20 m with no additional collection optics, corresponding to a collection solid angle of 0.2 μsr, or f/2000, and also using a small telescope to increase the collection efficiency. The use of a microphone was demonstrated to rapidly optimize laser focus for 20 m standoff LIBS measurements.

  3. [Research on fast classification based on LIBS technology and principle component analyses].

    Science.gov (United States)

    Yu, Qi; Ma, Xiao-Hong; Wang, Rui; Zhao, Hua-Feng

    2014-11-01

    Laser-induced breakdown spectroscopy (LIBS) and the principle component analysis (PCA) were combined to study aluminum alloy classification in the present article. Classification experiments were done on thirteen different kinds of standard samples of aluminum alloy which belong to 4 different types, and the results suggested that the LIBS-PCA method can be used to aluminum alloy fast classification. PCA was used to analyze the spectrum data from LIBS experiments, three principle components were figured out that contribute the most, the principle component scores of the spectrums were calculated, and the scores of the spectrums data in three-dimensional coordinates were plotted. It was found that the spectrum sample points show clear convergence phenomenon according to the type of aluminum alloy they belong to. This result ensured the three principle components and the preliminary aluminum alloy type zoning. In order to verify its accuracy, 20 different aluminum alloy samples were used to do the same experiments to verify the aluminum alloy type zoning. The experimental result showed that the spectrum sample points all located in their corresponding area of the aluminum alloy type, and this proved the correctness of the earlier aluminum alloy standard sample type zoning method. Based on this, the identification of unknown type of aluminum alloy can be done. All the experimental results showed that the accuracy of principle component analyses method based on laser-induced breakdown spectroscopy is more than 97.14%, and it can classify the different type effectively. Compared to commonly used chemical methods, laser-induced breakdown spectroscopy can do the detection of the sample in situ and fast with little sample preparation, therefore, using the method of the combination of LIBS and PCA in the areas such as quality testing and on-line industrial controlling can save a lot of time and cost, and improve the efficiency of detection greatly.

  4. Development of an Automated LIBS Analytical Test System Integrated with Component Control and Spectrum Analysis Capabilities

    International Nuclear Information System (INIS)

    Ding Yu; Tian Di; Chen Feipeng; Chen Pengfei; Qiao Shujun; Yang Guang; Li Chunsheng

    2015-01-01

    The present paper proposes an automated Laser-Induced Breakdown Spectroscopy (LIBS) analytical test system, which consists of a LIBS measurement and control platform based on a modular design concept, and a LIBS qualitative spectrum analysis software and is developed in C#. The platform provides flexible interfacing and automated control; it is compatible with different manufacturer component models and is constructed in modularized form for easy expandability. During peak identification, a more robust peak identification method with improved stability in peak identification has been achieved by applying additional smoothing on the slope obtained by calculation before peak identification. For the purpose of element identification, an improved main lines analysis method, which detects all elements on the spectral peak to avoid omission of certain elements without strong spectral lines, is applied to element identification in the tested LIBS samples. This method also increases the identification speed. In this paper, actual applications have been carried out. According to tests, the analytical test system is compatible with components of various models made by different manufacturers. It can automatically control components to get experimental data and conduct filtering, peak identification and qualitative analysis, etc. on spectral data. (paper)

  5. Large-Scale Transcriptome Analysis in Faba Bean (Vicia faba L. under Ascochyta fabae Infection.

    Directory of Open Access Journals (Sweden)

    Sara Ocaña

    Full Text Available Faba bean is an important food crop worldwide. However, progress in faba bean genomics lags far behind that of model systems due to limited availability of genetic and genomic information. Using the Illumina platform the faba bean transcriptome from leaves of two lines (29H and Vf136 subjected to Ascochyta fabae infection have been characterized. De novo transcriptome assembly provided a total of 39,185 different transcripts that were functionally annotated, and among these, 13,266 were assigned to gene ontology against Arabidopsis. Quality of the assembly was validated by RT-qPCR amplification of selected transcripts differentially expressed. Comparison of faba bean transcripts with those of better-characterized plant genomes such as Arabidopsis thaliana, Medicago truncatula and Cicer arietinum revealed a sequence similarity of 68.3%, 72.8% and 81.27%, respectively. Moreover, 39,060 single nucleotide polymorphism (SNP and 3,669 InDels were identified for genotyping applications. Mapping of the sequence reads generated onto the assembled transcripts showed that 393 and 457 transcripts were overexpressed in the resistant (29H and susceptible genotype (Vf136, respectively. Transcripts involved in plant-pathogen interactions such as leucine rich proteins (LRR or plant growth regulators involved in plant adaptation to abiotic and biotic stresses were found to be differently expressed in the resistant line. The results reported here represent the most comprehensive transcript database developed so far in faba bean, providing valuable information that could be used to gain insight into the pathways involved in the resistance mechanism against A. fabae and to identify potential resistance genes to be further used in marker assisted selection.

  6. A Combined Remote LIBS and Raman Spectroscopic Study of Minerals

    Science.gov (United States)

    Hubble, H. W.; Ghosh, M.; Sharma, S. K.; Horton, K. A.; Lucey, P. G.; Angel, S. M.; Wiens, R. C.

    2002-01-01

    In this paper, we explore the use of remote LIBS combined with pulsed-laser Raman spectroscopy for mineral analysis at a distance of 10 meters. Samples analyzed include: carbonates (both biogenic and abiogenic), silicates, and sulfates. Additional information is contained in the original extended abstract.

  7. Comparative Transcriptome Analysis of the Necrotrophic Fungus Ascochyta rabiei during Oxidative Stress: Insight for Fungal Survival in the Host Plant

    Science.gov (United States)

    Singh, Kunal; Nizam, Shadab; Sinha, Manisha; Verma, Praveen K.

    2012-01-01

    Localized cell death, known as the hypersensitive response (HR), is an important defense mechanism for neutralizing phytopathogens. The hallmark of the HR is an oxidative burst produced by the host plant. We aimed to identify genes of the necrotrophic chickpea blight fungus Ascochyta rabiei that are involved in counteracting oxidative stress. A subtractive cDNA library was constructed after menadione treatment, which resulted in the isolation of 128 unigenes. A reverse northern blot was used to compare transcript profiles after H2O2, menadione and sodium nitroprusside treatments. A total of 70 unigenes were found to be upregulated by more than two-fold following menadione treatment at different time intervals. A large number of genes not previously associated with oxidative stress were identified, along with many stress-responsive genes. Differential expression patterns of several genes were validated by quantitative real-time PCR (qRT-PCR) and northern blotting. In planta qRT-PCR of several selected genes also showed differential expression patterns during infection and disease progression. These data shed light on the molecular responses of the phytopathogen A. rabiei to overcome oxidative and nitrosative stresses and advance the understanding of necrotrophic fungal pathogen survival mechanisms. PMID:22427966

  8. Assessment and forensic application of laser-induced breakdown spectroscopy (LIBS) for the discrimination of Australian window glass.

    Science.gov (United States)

    El-Deftar, Moteaa M; Speers, Naomi; Eggins, Stephen; Foster, Simon; Robertson, James; Lennard, Chris

    2014-08-01

    A commercially available laser-induced breakdown spectroscopy (LIBS) instrument was evaluated for the determination of elemental composition of twenty Australian window glass samples, consisting of 14 laminated samples and 6 non-laminated samples (or not otherwise specified) collected from broken windows at crime scenes. In this study, the LIBS figures of merit were assessed in terms of accuracy, limits of detection and precision using three standard reference materials (NIST 610, 612, and 1831). The discrimination potential of LIBS was compared to that obtained using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), X-ray microfluorescence spectroscopy (μXRF) and scanning electron microscopy energy dispersive X-ray spectrometry (SEM-EDX) for the analysis of architectural window glass samples collected from crime scenes in the Canberra region, Australia. Pairwise comparisons were performed using a three-sigma rule, two-way ANOVA and Tukey's HSD test at 95% confidence limit in order to investigate the discrimination power for window glass analysis. The results show that the elemental analysis of glass by LIBS provides a discrimination power greater than 97% (>98% when combined with refractive index data), which was comparable to the discrimination powers obtained by LA-ICP-MS and μXRF. These results indicate that LIBS is a feasible alternative to the more expensive LA-ICP-MS and μXRF options for the routine forensic analysis of window glass samples. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  9. El vuelo zumbón de la libélula

    Directory of Open Access Journals (Sweden)

    Fernando González Cajiao

    1992-01-01

    Full Text Available Delírium titerensis. Tres obras de la Libélula Dorada: el dulce encanto de la isla Acracic, Los espíritus lúdicos y Ese chivo es puro cuento (ilustraciones de Carlos Rojas. Arango Editores, Bogotá, 1991, 129 págs.

  10. Getting More Value from the LibQUAL+® Survey: The Merits of Qualitative Analysis and Importance-Satisfaction Matrices in Assessing Library Patron Comments

    Science.gov (United States)

    Detlor, Brian; Ball, Kathryn

    2015-01-01

    This paper examines the merit of conducting a qualitative analysis of LibQUAL+® survey comments as a means of leveraging quantitative LibQUAL+ results, and using importance-satisfaction matrices to present and assess qualitative findings. Comments collected from the authors' institution's LibQUAL+ survey were analyzed using a codebook based on…

  11. LibGuide som social platform

    DEFF Research Database (Denmark)

    Nielsen, Susanne; Volder Kjær, Berit; Andersen, Bente Thorup

    2011-01-01

    undervisningsforløb. Det er formålet herved at højne både kvaliteten af undervisningen og udviklingen af elevernes informationskompetence. LibGuide er planlagt til at skulle understøtte en kommunikativ forståelse og samarbejdet mellem eleverne og bibliotekar/lærer, dvs. der er fokus på det sociale aspekt. Artiklen...... viser at de nævnte mål indebærer et eksplorativt udviklingsforløb. Udviklingen af et værktøj, der skal indfri de nævnte samarbejdsmæssige aspekter, forudsætter en evalueringsproces, hvor der gives tid til erhvervelsen af mange erfaringer og refleksioner. Artiklen gør rede for de ideer, der ligger bag...

  12. ANALISIS UNSUR Ag PADA SAMPEL CAIR DENGAN LASER INDUCED BREAKDOWN SPECTROSCOPY (LIBS

    Directory of Open Access Journals (Sweden)

    Sinaga Natalia Declarossy

    2014-02-01

    Full Text Available It has been done research on the analysis of Ag element in the liquid electrolyte with Laser Induced Breakdown Spectroscopy (LIBS through electrolysis method. Observations conducted by LIBS using Nd-YAG laser (1064nm, 7ns. Prior to analyze, first looking for the optimum conditions of experiments had been done. The results showed that the optimum laser energy to the characterization of the elements Ag was 100 mJ and optimum conditions of electric current and time deposition on electrolysis process were 4.93 mA and 10 minutes, respectively. These conditions, next, for the application of quantitative analysis of Ag solution that started from concentration 300 ppm to the lowest concentration and limit of detection obtained 1 ppm.

  13. Decomposition and correction overlapping peaks of LIBS using an error compensation method combined with curve fitting.

    Science.gov (United States)

    Tan, Bing; Huang, Min; Zhu, Qibing; Guo, Ya; Qin, Jianwei

    2017-09-01

    The laser induced breakdown spectroscopy (LIBS) technique is an effective method to detect material composition by obtaining the plasma emission spectrum. The overlapping peaks in the spectrum are a fundamental problem in the qualitative and quantitative analysis of LIBS. Based on a curve fitting method, this paper studies an error compensation method to achieve the decomposition and correction of overlapping peaks. The vital step is that the fitting residual is fed back to the overlapping peaks and performs multiple curve fitting processes to obtain a lower residual result. For the quantitative experiments of Cu, the Cu-Fe overlapping peaks in the range of 321-327 nm obtained from the LIBS spectrum of five different concentrations of CuSO 4 ·5H 2 O solution were decomposed and corrected using curve fitting and error compensation methods. Compared with the curve fitting method, the error compensation reduced the fitting residual about 18.12-32.64% and improved the correlation about 0.86-1.82%. Then, the calibration curve between the intensity and concentration of the Cu was established. It can be seen that the error compensation method exhibits a higher linear correlation between the intensity and concentration of Cu, which can be applied to the decomposition and correction of overlapping peaks in the LIBS spectrum.

  14. Using LibGuides to enhance library services a LITA guide

    CERN Document Server

    Dobbs, Aaron W

    2013-01-01

    The easy-to-use tools in Springshare's LibGuides help you organize webpages, improve students' research experience and learning, and offer an online community of librarians sharing their work and ideas. Editors Dobbs, Sittler, and Cook have recruited expert contributors to address specific applications, creating a one-stop reference.

  15. [Quantitative Analysis of Heavy Metals in Water with LIBS Based on Signal-to-Background Ratio].

    Science.gov (United States)

    Hu, Li; Zhao, Nan-jing; Liu, Wen-qing; Fang, Li; Zhang, Da-hai; Wang, Yin; Meng, De Shuo; Yu, Yang; Ma, Ming-jun

    2015-07-01

    There are many influence factors in the precision and accuracy of the quantitative analysis with LIBS technology. According to approximately the same characteristics trend of background spectrum and characteristic spectrum along with the change of temperature through in-depth analysis, signal-to-background ratio (S/B) measurement and regression analysis could compensate the spectral line intensity changes caused by system parameters such as laser power, spectral efficiency of receiving. Because the measurement dates were limited and nonlinear, we used support vector machine (SVM) for regression algorithm. The experimental results showed that the method could improve the stability and the accuracy of quantitative analysis of LIBS, and the relative standard deviation and average relative error of test set respectively were 4.7% and 9.5%. Data fitting method based on signal-to-background ratio(S/B) is Less susceptible to matrix elements and background spectrum etc, and provides data processing reference for real-time online LIBS quantitative analysis technology.

  16. Applicability of Machine-Learning Enabled LIBS in Post Irradiation Nuclear Forensic Analysis of High Level Waste

    International Nuclear Information System (INIS)

    Onkongi, J.; Maina, D.; Angeyo, H.K.

    2017-01-01

    Nuclear Forensics seeks Information to determine; Chemical Composition, Routes of transit, Origin (Provenance) and Intended use. Post Irradiation/Post detonation NF In a post-detonation event could you get clues/signatures from glass debris, minute sample sizes? Nuclear Forensic Technique Should be State-of -the art that is Rapid, Non-invasive, Remote ability and Non-destructive. Laser Induced Breakdown Spectroscopy (LIBS) unlike other Analytic Techniques that require tedious sample preparations such as Dissolution, digestion & matrix removal, which generate additional nuclear wastes that require proper Procedures for handling, storage & ultimate disposal, LIBS overcomes these limitations. Utility of Machine Learning Techniques employed include; Artificial Neural Networks, ANN (Regression/Modelling), Principal component Analysis, PCA (Classification) and Support Vector Machine SVM (Comparative study/Classification Machine Learning coupled with LIBS gives a state of the art analytic method. Utility of the technic in safeguards security and non-proliferation

  17. Correlation between Fe–V–C alloys surface hardness and plasma temperature via LIBS technique

    Energy Technology Data Exchange (ETDEWEB)

    Messaoud Aberkane, S., E-mail: smessaoud@cdta.dz [Centre de Développement des Technologies Avancées, Baba Hassen, Alger (Algeria); Bendib, A. [Université des Sciences et de Technologie Houari Boumediene, Bab-Ezzouar, Alger (Algeria); Yahiaoui, K.; Boudjemai, S.; Abdelli-Messaci, S.; Kerdja, T. [Centre de Développement des Technologies Avancées, Baba Hassen, Alger (Algeria); Amara, S.E. [Université des Sciences et de Technologie Houari Boumediene, Bab-Ezzouar, Alger (Algeria); Harith, M.A. [National Institute of Laser Enhanced Science, Cairo University (Egypt)

    2014-05-01

    Highlights: • New application of LIBS in industry. • Hardness of metallic alloys estimation using LIBS calibration curves. • Linear correlation between the plasma temperature and the hardness of metallic alloys. • The shock wave is fast when the material is hard. - Abstract: Surface hardness is a very important characteristic of metals. Its monitoring plays a key role in industry. In the present paper, using laser induced breakdown spectroscopy (LIBS), Fe–V{sub 18%}–C{sub 1%} alloys with different heat treatments have been used for making the correlation between surface hardness and laser-induced plasma temperatures. All investigated samples were characterized by the same ferrite phase with different Vickers surface hardnesses. The differences in hardness values were attributed to the crystallite size changes. A linear relationship has been obtained between the Vickers surface hardness and the laser induced plasma temperature. For comparison the relation between surface hardness and the ratio of the vanadium ionic to atomic spectral lines intensities (VII/VI) provided good linear results too. However, adopting the proposed approach of using the plasma temperature, instead, is more reliable in view of the difficulties that could be encountered in choosing the proper ionic and atomic spectral lines. To validate this approach we have investigated the shock wave speed induced by laser interaction with the used samples. It was found that harder is the material faster is the shock wave. The determination of the surface hardness via measuring T{sub e} shows the feasibility of using LIBS as an easy and reliable method for in situ industrial application for production control.

  18. Detection of pesticides and dioxins in tissue fats and rendering oils using laser-induced breakdown spectroscopy (LIBS).

    Science.gov (United States)

    Multari, Rosalie A; Cremers, David A; Scott, Thomas; Kendrick, Peter

    2013-03-13

    In laser-induced breakdown spectroscopy (LIBS), a series of powerful laser pulses are directed at a surface to form microplasmas from which light is collected and spectrally analyzed to identify the surface material. In most cases, no sample preparation is needed, and results can be automated and made available within seconds to minutes. Advances in LIBS spectral data analysis using multivariate regression techniques have led to the ability to detect organic chemicals in complex matrices such as foods. Here, the use of LIBS to differentiate samples contaminated with aldrin, 1,2,3,4,6,7,8-heptachlorodibenzo-p-dioxin, chlorpyrifos, and dieldrin in the complex matrices of tissue fats and rendering oils is described. The pesticide concentrations in the samples ranged from 0.005 to 0.1 μg/g. All samples were successfully differentiated from each other and from control samples. Sample concentrations could also be differentiated for all of the pesticides and the dioxin included in this study. The results presented here provide first proof-of-principle data for the ability to create LIBS-based instrumentation for the rapid analysis of pesticide and dioxin contamination in tissue fat and rendered oils.

  19. Direct measurements of sample heating by a laser-induced air plasma in pre-ablation spark dual-pulse laser-induced breakdown spectroscopy (LIBS).

    Science.gov (United States)

    Register, Janna; Scaffidi, Jonathan; Angel, S Michael

    2012-08-01

    Direct measurements of temperature changes were made using small thermocouples (TC), placed near a laser-induced air plasma. Temperature changes up to ~500 °C were observed. From the measured temperature changes, estimates were made of the amount of heat absorbed per unit area. This allowed calculations to be made of the surface temperature, as a function of time, of a sample heated by the air plasma that is generated during orthogonal pre-ablation spark dual-pulse (DP) LIBS measurements. In separate experiments, single-pulse (SP) LIBS emission and sample ablation rate measurements were performed on nickel at sample temperatures ranging from room temperature to the maximum surface temperature that was calculated using the TC measurement results (500 °C). A small, but real sample temperature-dependent increase in both SP LIBS emission and the rate of sample ablation was found for nickel samples heated up to 500 °C. Comparison of DP LIBS emission enhancement values for bulk nickel samples at room temperature versus the enhanced SP LIBS emission and sample ablation rates observed as a function of increasing sample temperature suggests that sample heating by the laser-induced air plasma plays only a minor role in DP LIBS emission enhancement.

  20. Lithium tri borate (LiB3O5) embedded polymer electret for mechanical sensing application

    Science.gov (United States)

    Murugan, S.; Praveen, E.; Prasad, M. V. N.; Jayakumar, K.

    2017-05-01

    Lithium tri borate (LiB3O5) particles were synthesized by precipitation assisted high temperature solid state reaction. The particles were embedded in chitosan polymer and used as an electret. This electret was characterized for the suitability as a sensing element in vibration accelerometer. It is observed that LiB3O5 embedded electret exhibiting piezoelectric property. The electret is also giving an isolation of > 999 MΩ at 100 Vdc, 250 Vdc, 500 Vdc and 1kVdc confirms compatible for intrinsically safe sensing alternative in vibration accelerometer.

  1. Evidence and Consequence of a Highly Adapted Clonal Haplotype within the Australian Ascochyta rabiei Population

    Directory of Open Access Journals (Sweden)

    Yasir Mehmood

    2017-06-01

    Full Text Available The Australian Ascochyta rabiei (Pass. Labr. (syn. Phoma rabiei population has low genotypic diversity with only one mating type detected to date, potentially precluding substantial evolution through recombination. However, a large diversity in aggressiveness exists. In an effort to better understand the risk from selective adaptation to currently used resistance sources and chemical control strategies, the population was examined in detail. For this, a total of 598 isolates were quasi-hierarchically sampled between 2013 and 2015 across all major Australian chickpea growing regions and commonly grown host genotypes. Although a large number of haplotypes were identified (66 through short sequence repeat (SSR genotyping, overall low gene diversity (Hexp = 0.066 and genotypic diversity (D = 0.57 was detected. Almost 70% of the isolates assessed were of a single dominant haplotype (ARH01. Disease screening on a differential host set, including three commonly deployed resistance sources, revealed distinct aggressiveness among the isolates, with 17% of all isolates identified as highly aggressive. Almost 75% of these were of the ARH01 haplotype. A similar pattern was observed at the host level, with 46% of all isolates collected from the commonly grown host genotype Genesis090 (classified as “resistant” during the term of collection identified as highly aggressive. Of these, 63% belonged to the ARH01 haplotype. In conclusion, the ARH01 haplotype represents a significant risk to the Australian chickpea industry, being not only widely adapted to the diverse agro-geographical environments of the Australian chickpea growing regions, but also containing a disproportionately large number of aggressive isolates, indicating fitness to survive and replicate on the best resistance sources in the Australian germplasm.

  2. FermiLib v0.1

    Energy Technology Data Exchange (ETDEWEB)

    2017-02-27

    FermiLib is an open source software package designed to facilitate the development and testing of algorithms for simulations of fermionic systems on quantum computers. Fermionic simulations represent an important application of early quantum devices with a lot of potential high value targets, such as quantum chemistry for the development of new catalysts. This software strives to provide a link between the required domain expertise in specific fermionic applications and quantum computing to enable more users to directly interface with, and develop for, these applications. It is an extensible Python library designed to interface with the high performance quantum simulator, ProjectQ, as well as application specific software such as PSI4 from the domain of quantum chemistry. Such software is key to enabling effective user facilities in quantum computation research.

  3. Incorporation of support vector machines in the LIBS toolbox for sensitive and robust classification amidst unexpected sample and system variability.

    Science.gov (United States)

    Dingari, Narahara Chari; Barman, Ishan; Myakalwar, Ashwin Kumar; Tewari, Surya P; Kumar Gundawar, Manoj

    2012-03-20

    Despite the intrinsic elemental analysis capability and lack of sample preparation requirements, laser-induced breakdown spectroscopy (LIBS) has not been extensively used for real-world applications, e.g., quality assurance and process monitoring. Specifically, variability in sample, system, and experimental parameters in LIBS studies present a substantive hurdle for robust classification, even when standard multivariate chemometric techniques are used for analysis. Considering pharmaceutical sample investigation as an example, we propose the use of support vector machines (SVM) as a nonlinear classification method over conventional linear techniques such as soft independent modeling of class analogy (SIMCA) and partial least-squares discriminant analysis (PLS-DA) for discrimination based on LIBS measurements. Using over-the-counter pharmaceutical samples, we demonstrate that the application of SVM enables statistically significant improvements in prospective classification accuracy (sensitivity), because of its ability to address variability in LIBS sample ablation and plasma self-absorption behavior. Furthermore, our results reveal that SVM provides nearly 10% improvement in correct allocation rate and a concomitant reduction in misclassification rates of 75% (cf. PLS-DA) and 80% (cf. SIMCA)-when measurements from samples not included in the training set are incorporated in the test data-highlighting its robustness. While further studies on a wider matrix of sample types performed using different LIBS systems is needed to fully characterize the capability of SVM to provide superior predictions, we anticipate that the improved sensitivity and robustness observed here will facilitate application of the proposed LIBS-SVM toolbox for screening drugs and detecting counterfeit samples, as well as in related areas of forensic and biological sample analysis.

  4. The effect of bacterial environmental and metabolic stresses on a laser-induced breakdown spectroscopy (LIBS) based identification of Escherichia coli and Streptococcus viridans.

    Science.gov (United States)

    Mohaidat, Qassem; Palchaudhuri, Sunil; Rehse, Steven J

    2011-04-01

    In this paper we investigate the effect that adverse environmental and metabolic stresses have on the laser-induced breakdown spectroscopy (LIBS) identification of bacterial specimens. Single-pulse LIBS spectra were acquired from a non-pathogenic strain of Escherichia coli cultured in two different nutrient media: a trypticase soy agar and a MacConkey agar with a 0.01% concentration of deoxycholate. A chemometric discriminant function analysis showed that the LIBS spectra acquired from bacteria grown in these two media were indistinguishable and easily discriminated from spectra acquired from two other non-pathogenic E. coli strains. LIBS spectra were obtained from specimens of a nonpathogenic E. coli strain and an avirulent derivative of the pathogen Streptococcus viridans in three different metabolic situations: live bacteria reproducing in the log-phase, bacteria inactivated on an abiotic surface by exposure to bactericidal ultraviolet irradiation, and bacteria killed via autoclaving. All bacteria were correctly identified regardless of their metabolic state. This successful identification suggests the possibility of testing specimens that have been rendered safe for handling prior to LIBS identification. This would greatly enhance personnel safety and lower the cost of a LIBS-based diagnostic test. LIBS spectra were obtained from pathogenic and non-pathogenic bacteria that were deprived of nutrition for a period of time ranging from one day to nine days by deposition on an abiotic surface at room temperature. All specimens were successfully classified by species regardless of the duration of nutrient deprivation. © 2011 Society for Applied Spectroscopy

  5. Depth-resolved multilayer pigment identification in paintings: combined use of laser-induced breakdown spectroscopy (LIBS) and optical coherence tomography (OCT).

    Science.gov (United States)

    Kaszewska, Ewa A; Sylwestrzak, Marcin; Marczak, Jan; Skrzeczanowski, Wojciech; Iwanicka, Magdalena; Szmit-Naud, Elżbieta; Anglos, Demetrios; Targowski, Piotr

    2013-08-01

    A detailed feasibility study on the combined use of laser-induced breakdown spectroscopy with optical coherence tomography (LIBS/OCT), aiming at a realistic depth-resolved elemental analysis of multilayer stratigraphies in paintings, is presented. Merging a high spectral resolution LIBS system with a high spatial resolution spectral OCT instrument significantly enhances the quality and accuracy of stratigraphic analysis. First, OCT mapping is employed prior to LIBS analysis in order to assist the selection of specific areas of interest on the painting surface to be examined in detail. Then, intertwined with LIBS, the OCT instrument is used as a precise profilometer for the online determination of the depth of the ablation crater formed by individual laser pulses during LIBS depth-profile analysis. This approach is novel and enables (i) the precise in-depth scaling of elemental concentration profiles, and (ii) the recognition of layer boundaries by estimating the corresponding differences in material ablation rate. Additionally, the latter is supported, within the transparency of the object, by analysis of the OCT cross-sectional views. The potential of this method is illustrated by presenting results on the detailed analysis of the structure of an historic painting on canvas performed to aid planned restoration of the artwork.

  6. Evaluation of laser-induced breakdown spectroscopy (LIBS) for measurement of silica on filter samples of coal dust.

    Science.gov (United States)

    Stipe, Christopher B; Miller, Arthur L; Brown, Jonathan; Guevara, Edward; Cauda, Emanuele

    2012-11-01

    Airborne silica dust (quartz) is common in coal mines and represents a respiratory hazard that can lead to silicosis, a potentially fatal lung disease. With an eye toward developing a portable monitoring device for rapid analysis of silica dust, laser-induced breakdown spectroscopy (LIBS) was used to quantify quartz in coal dust samples collected on filter media. Pure silica (Min-U-Sil™ 5), Georgia kaolin, and Pittsburgh-4 and Illinois-6 coal dusts were deposited separately and at multiple mass loadings onto 37-mm polyvinylchloride (PVC) filters. LIBS-generated silicon emission was monitored at 288.16 nm, and non-silica contributions to that signal from kaolinite were removed by simultaneously detecting aluminum. Measurements of the four samples were used to calculate limits of detection (LOD) for silicon and aluminum of approximately 0.08 μg/cm(2) and 0.05 μg/cm(2), respectively (corresponding to 0.16 μg/cm(2) and 0.20 μg/cm(2) for silica and kaolinite, respectively). Relative errors of prediction are around 10%. Results demonstrate that LIBS can dependably quantify silica on filter samples of coal dust and confirm that accurate quantification can be achieved for very lightly loaded samples, which supports the potential application of LIBS for rapid, in-field monitoring.

  7. Determination of Rare Earth Elements in Geological Samples Using Laser-Induced Breakdown Spectroscopy (LIBS).

    Science.gov (United States)

    Bhatt, Chet R; Jain, Jinesh C; Goueguel, Christian L; McIntyre, Dustin L; Singh, Jagdish P

    2018-01-01

    Laser-induced breakdown spectroscopy (LIBS) was used to detect rare earth elements (REEs) in natural geological samples. Low and high intensity emission lines of Ce, La, Nd, Y, Pr, Sm, Eu, Gd, and Dy were identified in the spectra recorded from the samples to claim the presence of these REEs. Multivariate analysis was executed by developing partial least squares regression (PLS-R) models for the quantification of Ce, La, and Nd. Analysis of unknown samples indicated that the prediction results of these samples were found comparable to those obtained by inductively coupled plasma mass spectrometry analysis. Data support that LIBS has potential to quantify REEs in geological minerals/ores.

  8. A matrix effect and accuracy evaluation for the determination of elements in milk powder LIBS and laser ablation/ICP-OES spectrometry.

    Science.gov (United States)

    Gilon, N; El-Haddad, J; Stankova, A; Lei, W; Ma, Q; Motto-Ros, V; Yu, J

    2011-11-01

    Laser ablation coupled to inductively coupled plasma optical emission spectrometry (LA-ICP-OES) and laser-induced breakdown spectroscopy (LIBS) were investigated for the determination of Ca, Mg, Zn and Na in milk samples. The accuracy of both methods was evaluated by comparison of the concentration found using LA-ICP-OES and LIBS with classical wet digestion associated with ICP-OES determination. The results were not fully acceptable, with biases from less than 1% to more than 60%. Matrix effects were also investigated. The sample matrix can influence the temperature, electron number density (n (e)) and other excitation characteristics in the ICP. These ICP characteristics were studied and evaluated during ablation of eight milk samples. Differences in n (e) (from 8.9 to 13.8 × 10(14) cm(-3)) and rotational temperature (ranging from 3,400 to 4,400 K) occurred with no correlation with trueness. LIBS results obtained after classical external calibration procedure gave degraded accuracy, indicating a strong matrix effect. The LIBS measurements clearly showed that the major problem in LA-ICP was related to the ablation process and that LIBS spectroscopy is an excellent diagnostic tool for LA-ICP techniques.

  9. Applicability of Machine-Learning Enabled LIBS in Post Irradiation Nuclear Forensic Analysis of High Level Nuclear Waste

    International Nuclear Information System (INIS)

    Onkongi, J.; Maina, D.; Angeyo, H. K.

    2017-01-01

    Nuclear Forensics seeks Information to determine; Chemical Composition, Routes of transit, Origin (Provenance) and Intended use. Post Irradiation/Post detonation NF In a post-detonation event could you get clues/signatures from glass debris, minute sample sizes? Nuclear Forensic Technique Should be State-of -the art that is Rapid, Non-invasive, Remote ability and Non-destructive. Laser Induced Breakdown Spectroscopy (LIBS) unlike other Analytic Techniques that require tedious sample preparations such as Dissolution, digestion & matrix removal, which generate additional nuclear wastes that require proper Procedures for handling, storage & ultimate disposal, LIBS overcomes these limitations. Utility of Machine Learning Techniques employed include; Artificial Neural Networks, ANN (Regression/Modelling), Principal component Analysis, PCA (Classification) and Support Vector Machine SVM (Comparative study/Classification Machine Learning coupled with LIBS gives a state of the art analytic method. Utility of the technic in safeguards security and non-proliferation

  10. Fabrication of Si negative electrodes for Li-ion batteries (LIBs) using cross-linked polymer binders.

    Science.gov (United States)

    Jang, Suk-Yong; Han, Sien-Ho

    2016-12-19

    Currently, Si as an active material for LIBs has been attracting much attention due to its high theoretical specific capacity (3572 mAh g -1 ). However, a disadvantage when using a Si negative electrode for LIBs is the abrupt drop of its capabilities during the cycling process. Therefore, there have been a few studies of polymers such as poly(vinylidene fluoride) (PVdF), carboxymethyl cellulose (CMC), styrene butadiene rubber (SBR) and polyacrylic acid (PAA) given that the robust structure of a polymeric binder to LIBs anodes is a promising means by which to enhance the performance of high-capacity anodes. These studies essentially focused mainly on modifying of the linear-polymer component or on copolymers dissolved in solvents. Cross-linking polymers as a binder may be preferred due to their good scratch resistance, excellent chemical resistance and high levels of adhesion and resilience. However, because these types of polymers (with a rigid structure and cross-linking points) are also insoluble in general organic solvents, applying these types in this capacity is virtually impossible.

  11. Partial Least Squares and Neural Networks for Quantitative Calibration of Laser-induced Breakdown Spectroscopy (LIBs) of Geologic Samples

    Science.gov (United States)

    Anderson, R. B.; Morris, Richard V.; Clegg, S. M.; Humphries, S. D.; Wiens, R. C.; Bell, J. F., III; Mertzman, S. A.

    2010-01-01

    The ChemCam instrument [1] on the Mars Science Laboratory (MSL) rover will be used to obtain the chemical composition of surface targets within 7 m of the rover using Laser Induced Breakdown Spectroscopy (LIBS). ChemCam analyzes atomic emission spectra (240-800 nm) from a plasma created by a pulsed Nd:KGW 1067 nm laser. The LIBS spectra can be used in a semiquantitative way to rapidly classify targets (e.g., basalt, andesite, carbonate, sulfate, etc.) and in a quantitative way to estimate their major and minor element chemical compositions. Quantitative chemical analysis from LIBS spectra is complicated by a number of factors, including chemical matrix effects [2]. Recent work has shown promising results using multivariate techniques such as partial least squares (PLS) regression and artificial neural networks (ANN) to predict elemental abundances in samples [e.g. 2-6]. To develop, refine, and evaluate analysis schemes for LIBS spectra of geologic materials, we collected spectra of a diverse set of well-characterized natural geologic samples and are comparing the predictive abilities of PLS, cascade correlation ANN (CC-ANN) and multilayer perceptron ANN (MLP-ANN) analysis procedures.

  12. Determination of the penetration hardness and analysis of stainless steel alloys by means of Laser Induced Breakdown Spectroscopy (LIBS

    Directory of Open Access Journals (Sweden)

    mohamad Vahid Dastjerdi

    2017-11-01

    Full Text Available A significant feature of alloys is the surfaces hardness that is always accompanied by challenges when it’s measured by common mechanical techniques. In this investigation, we used Laser Induced Breakdown Spectroscopy (LIBS as a replacement method for common mechanical techniques to measure the surfaces hardness of different alloys. After recording the spectrum of alloy samples in order to identify the surface hardness of analyzed sample, K-Nearest Neighbors method (KNN was used and obtained results showed that the LIBS-KNN method can separate and identify the surfaces hardness of samples with precision of 93.3%. In addition, in order to identify the percentage of constituent elements of alloys and their hardness, calibration approach was investigated that showed there is an appropriate linear relation between recorded emission lines from the LIB spectra of sample alloys and the percentage of their constituent elements and also their Vickers hardness numbers. Therefore, According to exclusive advantages of LIBS technique i.e. high speed analysis, non-destructive analysis and being portable, some of available difficulties in conventional mechanical techniques can be removed.

  13. Rapid analysis of pharmaceutical drugs using LIBS coupled with multivariate analysis.

    Science.gov (United States)

    Tiwari, P K; Awasthi, S; Kumar, R; Anand, R K; Rai, P K; Rai, A K

    2018-02-01

    Type 2 diabetes drug tablets containing voglibose having dose strengths of 0.2 and 0.3 mg of various brands have been examined, using laser-induced breakdown spectroscopy (LIBS) technique. The statistical methods such as the principal component analysis (PCA) and the partial least square regression analysis (PLSR) have been employed on LIBS spectral data for classifying and developing the calibration models of drug samples. We have developed the ratio-based calibration model applying PLSR in which relative spectral intensity ratios H/C, H/N and O/N are used. Further, the developed model has been employed to predict the relative concentration of element in unknown drug samples. The experiment has been performed in air and argon atmosphere, respectively, and the obtained results have been compared. The present model provides rapid spectroscopic method for drug analysis with high statistical significance for online control and measurement process in a wide variety of pharmaceutical industrial applications.

  14. Calibration-free quantitative analysis of elemental ratios in intermetallic nanoalloys and nanocomposites using Laser Induced Breakdown Spectroscopy (LIBS).

    Science.gov (United States)

    Davari, Seyyed Ali; Hu, Sheng; Mukherjee, Dibyendu

    2017-03-01

    Intermetallic nanoalloys (NAs) and nanocomposites (NCs) have increasingly gained prominence as efficient catalytic materials in electrochemical energy conversion and storage systems. But their morphology and chemical compositions play critical role in tuning their catalytic activities, and precious metal contents. While advanced microscopy techniques facilitate morphological characterizations, traditional chemical characterizations are either qualitative or extremely involved. In this study, we apply Laser Induced Breakdown Spectroscopy (LIBS) for quantitative compositional analysis of NAs and NCs synthesized with varied elemental ratios by our in-house built pulsed laser ablation technique. Specifically, elemental ratios of binary PtNi, PdCo (NAs) and PtCo (NCs) of different compositions are determined from LIBS measurements employing an internal calibration scheme using the bulk matrix species as internal standards. Morphology and qualitative elemental compositions of the aforesaid NAs and NCs are confirmed from Transmission Electron Microscopy (TEM) images and Energy Dispersive X-ray Spectroscopy (EDX) measurements. LIBS experiments are carried out in ambient conditions with the NA and NC samples drop cast on silicon wafers after centrifugation to increase their concentrations. The technique does not call for cumbersome sample preparations including acid digestions and external calibration standards commonly required in Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES) techniques. Yet the quantitative LIBS results are in good agreement with the results from ICP-OES measurements. Our results indicate the feasibility of using LIBS in future for rapid and in-situ quantitative chemical characterizations of wide classes of synthesized NAs and NCs. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Identifikasi Unsur Radioaktif Pada Batako Ringan Aerasi Citicon Dengan Metode Laser Induced Breakdown Spectroscopy (LIBS

    Directory of Open Access Journals (Sweden)

    Wahyulianti Wahyulianti

    2016-02-01

    Full Text Available Research has been done to identify the radioactive elements in the Citicon aerated lightweight concrete block sample. In this research used a Citicon aerated lightweight concrete block as a sample with 1 cm x 3 cm in size and identification process used LIBS method. Radioactive elements identified in Citicon aerated lightweight concrete block the LIBS method were Th, Ra, and K. The number of photon emission intensity at the wavelength of each element is 396.710 nm, 620.033 nm, and 766.497 nm respectively by 62.33 a.u, 1.67 a.u, and 72.75 a.u.

  16. Single-shot LIBS spectral quality for waste particles in open air

    NARCIS (Netherlands)

    Xia, H.; Bakker, M.C.M.

    2015-01-01

    This work investigates the ability of LIBS to produce quality spectra from small particles of concrete demolition waste using single-shot spectra collected in open air. The 2–8?mm materials are rounded river gravel, green glass shards, and plastic flakes. Considered are focal length, air, moisture,

  17. Moon4You : a combined Raman/LIBS instrument for lunar exploration

    NARCIS (Netherlands)

    Laan, E.C.; Ahlers, B.; Westrenen, W.V.; Heiligers, J.; Wielders, A.

    2009-01-01

    Moon4You is a project led by the Dutch Organisation for Applied Scientific Research TNO, with partners from industry and universities in the Netherlands that aims to provide a combined Raman/LIBS instrument as scientific payload for lunar exploration missions. It is the first time that Raman

  18. Moon4You: A combined Raman / LIBS instrument for lunar exploration

    NARCIS (Netherlands)

    Laan, E.C.; Ahlers, B.; van Westrenen, W.; Heiligers, J.; Wielders, A.

    2009-01-01

    Moon4You is a project led by the Dutch Organisation for Applied Scientific Research TNO, with partners from industry and universities in the Netherlands that aims to provide a combined Raman/LIBS instrument as scientific payload for lunar exploration missions. It is the first time that Raman

  19. arriba-lib: evaluation of an electronic library of decision aids in primary care physicians

    Directory of Open Access Journals (Sweden)

    Hirsch Oliver

    2012-06-01

    Full Text Available Abstract Background The successful implementation of decision aids in clinical practice initially depends on how clinicians perceive them. Relatively little is known about the acceptance of decision aids by physicians and factors influencing the implementation of decision aids from their point of view. Our electronic library of decision aids (arriba-lib is to be used within the encounter and has a modular structure containing evidence-based decision aids for the following topics: cardiovascular prevention, atrial fibrillation, coronary heart disease, oral antidiabetics, conventional and intensified insulin therapy, and unipolar depression. The aim of our study was to evaluate the acceptance of arriba-lib in primary care physicians. Methods We conducted an evaluation study in which 29 primary care physicians included 192 patients. The physician questionnaire contained information on which module was used, how extensive steps of the shared decision making process were discussed, who made the decision, and a subjective appraisal of consultation length. We used generalised estimation equations to measure associations within patient variables and traditional crosstab analyses. Results Only a minority of consultations (8.9% was considered to be unacceptably extended. In 90.6% of consultations, physicians said that a decision could be made. A shared decision was perceived by physicians in 57.1% of consultations. Physicians said that a decision was more likely to be made when therapeutic options were discussed “detailed”. Prior experience with decision aids was not a critical variable for implementation within our sample of primary care physicians. Conclusions Our study showed that it might be feasible to apply our electronic library of decision aids (arriba-lib in the primary care context. Evidence-based decision aids offer support for physicians in the management of medical information. Future studies should monitor the long-term adoption of

  20. Dry Heat Treatment Reduces the Occurrence of Cladosporium cucumerinum, Ascochyta citrullina, and Colletotrichum orbiculare on the Surface and Interior of Cucumber Seeds

    Directory of Open Access Journals (Sweden)

    Yanxia Shi

    2016-01-01

    Full Text Available Dry heat treatment has been identified as a method for disinfecting seed-borne pathogens in vegetable seeds. This study demonstrated that three seed-borne pathogens of cucumber (Cladosporium cucumerinum that causes scabs, Ascochyta citrullina that results in gummy stem blight, and Colletotrichum orbiculare that induces anthracnose could be effectively eradicated from cucumber seeds by dry heat treatment. In vitro growth of these three pathogens was inhibited by dry heat treatment at 70 °C for 40 min. These pathogens were inactivated after exposing infected seeds to 70 °C dry heat for at least 90 min. Seed infection was significantly reduced by exposing the seeds to 70 °C dry heat for at least 40 min. Seed moisture content and germination were slightly reduced after 70 °C heat treatment for 40–120 min. Seed vigor remained at a high level after dry heat treatment at 70 °C for 90 min. In conclusion, 70 °C dry heat treatment for 90 min was determined to be the optimal method for eradication of C. cucumerinum, Didymella bryoniae, and C. orbiculare from cucumber seeds.

  1. Long-Wave Infrared (LWIR) Molecular Laser-Induced Breakdown Spectroscopy (LIBS) Emissions of Thin Solid Explosive Powder Films Deposited on Aluminum Substrates.

    Science.gov (United States)

    Yang, Clayton S-C; Jin, Feng; Trivedi, Sudhir B; Brown, Ei E; Hommerich, Uwe; Tripathi, Ashish; Samuels, Alan C

    2017-04-01

    Thin solid films made of high nitro (NO 2 )/nitrate (NO 3 ) content explosives were deposited on sand-blasted aluminum substrates and then studied using a mercury-cadmium-telluride (MCT) linear array detection system that is capable of rapidly capturing a broad spectrum of atomic and molecular laser-induced breakdown spectroscopy (LIBS) emissions in the long-wave infrared region (LWIR; ∼5.6-10 µm). Despite the similarities of their chemical compositions and structures, thin films of three commonly used explosives (RDX, HMX, and PETN) studied in this work can be rapidly identified in the ambient air by their molecular LIBS emission signatures in the LWIR region. A preliminary assessment of the detection limit for a thin film of RDX on aluminum appears to be much lower than 60 µg/cm 2 . This LWIR LIBS setup is capable of rapidly probing and charactering samples without the need for elaborate sample preparation and also offers the possibility of a simultaneous ultraviolet visible and LWIR LIBS measurement.

  2. Direct Determination of Contaminants and Major and Minor Nutrients in Solid Fertilizers Using Laser-Induced Breakdown Spectroscopy (LIBS).

    Science.gov (United States)

    Andrade, Daniel F; Pereira-Filho, Edenir Rodrigues

    2016-10-11

    Contaminants (Cd, Cr, and Pb) as well as minor (B, Cu, Mn, Na, and Zn) and major (Ca and Mg) elements were directly determined in solid fertilizer samples using laser-induced breakdown spectroscopy (LIBS). Factorial designs were used to define the most appropriate LIBS parameters and pellet pressure on solid fertilizers. Emission lines for all of the analytes were collected and employed 12 signal normalization modes. The best results were obtained using a laser energy of 75 mJ, a spot size of 50 μm, a pressure of 10 t/in., and a delay of 2.0 μs. Good correlation was obtained between the calibration model's prediction using the proposed LIBS method and the reference values obtained with ICP-OES. The limits of detection (LOD) for the proposed method varied from 2 mg/kg (for Cd) to 1% (for Zn).

  3. Qualitative and quantitative analysis of milk for the detection of adulteration by Laser Induced Breakdown Spectroscopy (LIBS).

    Science.gov (United States)

    Moncayo, S; Manzoor, S; Rosales, J D; Anzano, J; Caceres, J O

    2017-10-01

    The present work focuses on the development of a fast and cost effective method based on Laser Induced Breakdown Spectroscopy (LIBS) to the quality control, traceability and detection of adulteration in milk. Two adulteration cases have been studied; a qualitative analysis for the discrimination between different milk blends and quantification of melamine in adulterated toddler milk powder. Principal Component Analysis (PCA) and neural networks (NN) have been used to analyze LIBS spectra obtaining a correct classification rate of 98% with a 100% of robustness. For the quantification of melamine, two methodologies have been developed; univariate analysis using CN emission band and multivariate calibration NN model obtaining correlation coefficient (R 2 ) values of 0.982 and 0.999 respectively. The results of the use of LIBS technique coupled with chemometric analysis are discussed in terms of its potential use in the food industry to perform the quality control of this dairy product. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Laser-induced breakdown spectroscopy (LIBS) for rapid analysis of ash, potassium and magnesium in gluten free flours.

    Science.gov (United States)

    Markiewicz-Keszycka, Maria; Casado-Gavalda, Maria P; Cama-Moncunill, Xavier; Cama-Moncunill, Raquel; Dixit, Yash; Cullen, Patrick J; Sullivan, Carl

    2018-04-01

    Gluten free (GF) diets are prone to mineral deficiency, thus effective monitoring of the elemental composition of GF products is important to ensure a balanced micronutrient diet. The objective of this study was to test the potential of laser-induced breakdown spectroscopy (LIBS) analysis combined with chemometrics for at-line monitoring of ash, potassium and magnesium content of GF flours: tapioca, potato, maize, buckwheat, brown rice and a GF flour mixture. Concentrations of ash, potassium and magnesium were determined with reference methods and LIBS. PCA analysis was performed and presented the potential for discrimination of the six GF flours. For the quantification analysis PLSR models were developed; R 2 cal were 0.99 for magnesium and potassium and 0.97 for ash. The study revealed that LIBS combined with chemometrics is a convenient method to quantify concentrations of ash, potassium and magnesium and present the potential to classify different types of flours. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Good practices in LIBS analysis: Review and advices

    Energy Technology Data Exchange (ETDEWEB)

    El Haddad, J.; Canioni, L.; Bousquet, B., E-mail: bruno.bousquet@u-bordeaux.fr

    2014-11-01

    This paper presents a review on the analytical results obtained by laser-induced breakdown spectroscopy (LIBS). In the first part, results on identification and classification of samples are presented including the risk of misclassification, and in the second part, results on concentration measurement based on calibration are accompanied with significant figures of merit including the concept of accuracy. Both univariate and multivariate approaches are discussed with special emphasis on the methodology, the way of presenting the results and the assessment of the methods. Finally, good practices are proposed for both classification and concentration measurement.

  6. Good practices in LIBS analysis: Review and advices

    International Nuclear Information System (INIS)

    El Haddad, J.; Canioni, L.; Bousquet, B.

    2014-01-01

    This paper presents a review on the analytical results obtained by laser-induced breakdown spectroscopy (LIBS). In the first part, results on identification and classification of samples are presented including the risk of misclassification, and in the second part, results on concentration measurement based on calibration are accompanied with significant figures of merit including the concept of accuracy. Both univariate and multivariate approaches are discussed with special emphasis on the methodology, the way of presenting the results and the assessment of the methods. Finally, good practices are proposed for both classification and concentration measurement

  7. Qualitative and quantitative analysis of human nails to find correlation between nutrients and vitamin D deficiency using LIBS and ICP-AES.

    Science.gov (United States)

    Almessiere, M A; Altuwiriqi, R; Gondal, M A; AlDakheel, R K; Alotaibi, H F

    2018-08-01

    In this work, we analysed human fingernails of people who suffer from vitamin D deficiency using the laser-induced breakdown spectroscopy(LIBS) and inductively coupled plasma atomic emission spectroscopy (ICP-AES)techniques. The measurements have been conducted on 71 nail samples collected randomly from volunteers of different genders and ages ranged between 20 and 50 years. The main aim of this study is to find the correlation between vitamin D deficiency and the intensity of some dominated lines in the LIBS spectra. A LIBS spectrum consists of dominant lines of fifteen elements including calcium, magnesium, sodium, potassium, titanium, iron, chloride, sulphur, copper, chromium, zinc, nitrogen, phosphor, and oxygen. By recording the spectrum in specific ranges and focusing on calcium, magnesium, sodium, and potassium, we found a correlation between the intensity of the potassium (K) lines at (766.5 and 769.9 nm)and vitamin D level in both age groups (20 and 25 years old), with weak correlation for the calcium (Ca), magnesium (Mg), and sodium (Na) lines. To verify the validity of the LIBS results, we analysed the nail samples with ICP, a standard analytical technique. The elements detected with our LIBS technique are in a good agreement with those identified by ICP-AES. From the health and physiological perspectives, the LIBS system, which is used for spectral analysis in this work, is appropriate for diagnostic purposes such as to find the correlation between vitamin D deficiency and potassium content, especially for hypertensive patients who simultaneously take potassium-based medication and vitamin D supplement. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Navázání svazku Ti:Sa laseru do interakční komory v sestavě LIBS+LIFS

    OpenAIRE

    Vémola, Tomáš

    2009-01-01

    Práce se zabývá problematikou navázání svazku Ti:Safírového laseru do interakní komory v soustavě LIBS+LIFS. Cílem je navrhnout optickou soustavu s požadovanými vlastnostmi. Součástí práce je i teoretický popis základních principů atomové spektroskopie s důrazem na metodu LIBS+LIFS. In this work, the problem of focusing Ti:Sapphire laser beam into LIBS+LIFS interaction chamber is resolved. The task is to design an optical setup with demanded properties. Short theoretical description of the...

  9. Effect of self-absorption correction on surface hardness estimation of Fe-Cr-Ni alloys via LIBS.

    Science.gov (United States)

    Ramezanian, Zahra; Darbani, Seyyed Mohammad Reza; Majd, Abdollah Eslami

    2017-08-20

    The effect of self-absorption was investigated on the estimation of surface hardness of Fe-Cr-Ni metallic alloys by the laser-induced breakdown spectroscopy (LIBS) technique. For this purpose, the linear relationship between the ratio of chromium ionic to atomic line intensities (CrII/CrI) and surface hardness was studied, both before and after correcting the self-absorption effect. The correlation coefficient significantly increased from 47% to 90% after self-absorption correction. The results showed the measurements of surface hardness using LIBS can be more accurate and valid by correcting the self-absorption effect.

  10. Detection of heavy metals in soils by laser-induced breakdown spectroscopy (LIBS)

    International Nuclear Information System (INIS)

    Sirven, Jean-Baptiste

    2006-01-01

    In the fields of analysis, control and physical measurement, the laser constitutes a particularly powerful and multi-purpose metrological tool, capable to bring concrete solutions to various matters, including of a societal nature. Among the latter, contamination of sites and soils by heavy metals is an important issue of public health which requires to have measurement means adapted to existing regulations and whose use be sufficiently flexible. As a fast technique which does not need any sample preparation, laser-induced breakdown spectroscopy (LIBS) offers very interesting advantages for making on-site measurements of heavy metals content at the 10-ppm level; the design of a portable system is conceivable in the medium term. In this work we first show that the femtosecond regime presents no advantages with respect to the standard nanosecond regime for our issue. Then we implement an advanced treatment of LIBS spectra by chemometric techniques whose performances significantly improve the results of qualitative and quantitative analyses of soils samples. (author)

  11. The extraction and determination of free lithium in Li-B alloys

    International Nuclear Information System (INIS)

    Kilroy, W.P.; Angres, I.

    1979-01-01

    Extraction of the lithium phase from lithium-rich Li-B alloys was achieved by reaction of the alloy with dry naphthalene dissolved in anhydrous tetrahydrofuran. The resulting radical anion was hydrolyzed and the lithium was determined by potentiometric titration from the moles of hydroxide formed. The composition of the Lisub(x)Bsub(y) residue was determined by difference. (Auth.)

  12. Antagonism of Trichoderma spp. strains against pea (Pisum sativum L. Fusarium wilt caused by Fusarium oxysporum f. sp. pisi.

    Directory of Open Access Journals (Sweden)

    Oscar Eduardo Checa Coral

    2017-07-01

    Full Text Available The antagonistic effectiveness of native strains of Trichoderma spp. on Fusarium oxysporum f. sp. pisi. in vitro, greenhouse and field conditions, were evaluated. in vitro conditions, the antagonistic capacity of 12 strains of Trichoderma spp., C2, C7, C12 and C21 strains, exhibited a better behavior measured by the following variables: inhibition halo and mycelial growth. In greenhouse conditions, the four strains, which showed the best in vitro antagonistic behavior, were evaluated using a DIA experimental design with factorial arrangement for three factors, which corresponded to strain, concentration and dose. The results of this evaluation, showed that C12 and C21 strains at doses of 20 mL, and at concentrations of 108 and 106 conidia.mL-1, respectively. The best antagonistic response was determined by variables as follows: plant height, fresh root weight and incidence. Under field conditions, the evaluations were carried out in the municipalities of Ipiales, Pupiales and Gualmatán, in the department of Nariño, Colombia. In each location, a BCA experimental design was used with four treatments and five replicates, treatments were as follows: C12 strains at 108 concentration, C21 at 106 concentration, chemical control and absolute control. In Gualmatan location, C12 and C21 strains, showed no antagonistic capacity, whereas in Ipiales and Pupiales locations, strain C12, presented a lower incidence of F. oxysporum than the control, but with no effect on yields. In Pupiales location, C21 strain surpassed in performance to the control treatment, even though the two treatments had similar incidence.

  13. Education et Libération

    CERN Multimedia

    Jean-Pierre Lagnaux

    2013-01-01

    Vente d’artisanat du Tiers Monde Jeudi 23 et vendredi 24 mai 2013 CERN, Bâtiment principal Togo, Ecole Arc en ciel, construction des salles de classe. Appel pour le financement de ce chantier afin de libérer l’école de la charge des loyers payés pendant des années. Après nos réalisations en Amérique latine et au Bénin, nous mobilisons nos efforts pour l’école Arc en ciel de Kpeme, au Togo, sur les bords de l’Océan, à mi-chemin entre Lome et la frontière entre le Bénin et le Togo. Il s’agit d’une école primaire privée, laïque qui a très bonne réputation en termes de résultats, notamment pour les écoliers  en fin de scolarité primaire. Cela fait plusieurs années déjà que no...

  14. Development of a compact underwater laser-induced breakdown spectroscopy (LIBS) system and preliminary results in sea trials.

    Science.gov (United States)

    Guo, Jinjia; Lu, Yuan; Cheng, Kai; Song, Jiaojian; Ye, Wangquan; Li, Nan; Zheng, Ronger

    2017-10-10

    The exploitation and research of deep-sea hydrothermal vent has been an issue of great interest in ocean research in recent years. Laser-induced breakdown spectroscopy (LIBS) has great potential for ocean application due to the capabilities of stand-off, multiphase, and multielement analysis. In this work, a newly developed compact 4000 m rated LIBS system (LIBSea) is introduced with preliminary results of sea trials. The underwater system consists of an Nd:YAG single-pulsed laser operating at 1064 nm, an optical fiber spectrometer, an optics module, and an electronic controller module. The whole system is housed in an L800  mm×ϕ258  mm pressure housing with an optical window on the end cap. It was deployed on the remote operated vehicle Faxian on the research vessel Kexue, and in June 2015 was successfully applied for hydrothermal field measurements at the Manus area. The obtained results are shown that the LIBS system is capable of detecting elements Li, Na, K, Ca, and Mg in the hydrothermal area. Profiles of LIBS signals of elements K and Ca have also been obtained during the sea trial. The results show that the K emission line is gradually broadened with depth from sea surface to sea floor (1800 m or so); the K intensity shows a hump shape with maximum value at about 1050 m. The Ca emission line is rapidly broadened below 400 m and slowly narrowed to the sea floor; the Ca intensity shows no obvious change below 400 m and increases continuously to sea floor. A very interesting finding is that the small fluctuations of intensity profile curve of Ca show a degree of correlation with seawater temperature change. The sea trial results prove the performance of LIBSea. After further optimization, it is hoped to apply the LIBS system to the in situ mineral deposits and hydrothermal vent fluid detection in deep sea.

  15. Mixed Methods Not Mixed Messages: Improving LibGuides with Student Usability Data

    Directory of Open Access Journals (Sweden)

    Nora Almeida

    2017-12-01

    Full Text Available Abstract Objective – This article describes a mixed methods usability study of research guides created using the LibGuides 2.0 platform conducted in 2016 at an urban, public university library. The goal of the study was to translate user design and learning modality preferences into executable design principles, and ultimately to improve the design and usage of LibGuides at the New York City College of Technology Library. Methods – User-centred design demands that stakeholders participate in each stage of an application’s development and that assumptions about user design preferences are validated through testing. Methods used for this usability study include: a task analysis on paper prototypes with a think aloud protocol (TAP, an advanced scribbling technique modeled on the work of Linek and Tochtermann (2015, and semi-structured interviews. The authors introduce specifics of each protocol in addition to data collection and analysis methods. Results – The authors present quantitative and qualitative student feedback on navigation layouts, terminology, and design elements and discuss concrete institutional and technical measures they will take to implement best practices. Additionally, the authors discuss students’ impressions of multimedia, text-based, and interactive instructional content in relation to specific research scenarios defined during the usability test. Conclusion – The authors translate study findings into best practices that can be incorporated into custom user-centric LibGuide templates and assets. The authors also discuss relevant correlations between students’ learning modality preferences and design feedback, and identify several areas that warrant further research. The authors believe this study will spark a larger discussion about relationships between instructional design, learning modalities, and research guide use contexts.

  16. New ways for the quantification by the laser-induced plasma spectroscopy; Neue Wege zur Quantifizierung mit der laserinduzierten Plasmaspektroskopie (LIBS)

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Maike

    2010-04-27

    Laser Induced Breakdown Spectroscopy (LIBS) is capable of a fast and multielement analysis of various samples types and matrices which makes the method particularly attractive for industrial process analysis. However, for LIBS to become well accepted as an analytical method some issues in calibration and understanding of the underlying transient plasma processes have to be solved. The objective of this work was to identify influential instrumental parameters and plasma conditions in order to improve the overall quantitative performance of LIBS. As the spectral sensitivity and signal-to-noise ratio of the detector represents a decisive element for the application of LIBS in an industrial environment, two detectors, an ICCD and CCD camera, were compared. In combination with a high-resolution echelle spectrograph, the superior or at least equivalent efficiency of the non-intensified CCD was experimentally demonstrated and supported by corresponding plasma simulations. Further investigations of the plasma expansion under different atmospheric conditions revealed that the geometry of observing the expanding plasma influences the sensitivity and reproducibility of the measurements considerably. The diagnostics of self-absorbed spectral lines and their use for calibration purposes were studied with a mirror-based duplication method and a statistical line shape analysis employing linear correlation. The linear correlation approach displayed good performance for identifying the on-set of self absorption in comparison to the duplication method. As matrixmatched reference materials are essential to validate laser ablation methods, two novel preparations of individual calibration standards based on a copper-and polyacrylamide matrix were tested for their applicability to LIBS. (orig.)

  17. LIB LAB the Library Laboratory: hands-on multimedia science communication

    Science.gov (United States)

    Fillo, Aaron; Niemeyer, Kyle

    2017-11-01

    Teaching scientific research topics to K-12 audiences in an engaging and meaningful way does not need to be hard; with the right insight and techniques it can be fun to encourage self-guided STEAM (science, technology, engineering, arts, and mathematics) exploration. LIB LAB, short for Library Laboratory, is an educational video series produced by Aaron J. Fillo at Oregon State University in partnership with the Corvallis-Benton County Public Library targeted at K-12 students. Each episode explores a variety of scientific fundamentals with playful experiments and demonstrations. The video lessons are developed using evidence-based practices such as dispelling misconceptions, and language immersion. Each video includes directions for a related experiment that young viewers can conduct at home. In addition, science kits for these at-home experiments are distributed for free to students through the public library network in Benton County, Oregon. This talk will focus on the development of multimedia science education tools and several techniques that scientists can use to engage with a broad audience more effectively. Using examples from the LIB LAB YouTube Channel and collection of hands-on science demonstrations and take-home kits, this talk will present STEAM education in action. Corvallis-Benton County Public Library.

  18. Qualitative Analysis of Dairy and Powder Milk Using Laser-Induced Breakdown Spectroscopy (LIBS).

    Science.gov (United States)

    Alfarraj, Bader A; Sanghapi, Herve K; Bhatt, Chet R; Yueh, Fang Y; Singh, Jagdish P

    2018-01-01

    Laser-induced breakdown spectroscopy (LIBS) technique was used to compare various types of commercial milk products. Laser-induced breakdown spectroscopy spectra were investigated for the determination of the elemental composition of soy and rice milk powder, dairy milk, and lactose-free dairy milk. The analysis was performed using radiative transitions. Atomic emissions from Ca, K, Na, and Mg lines observed in LIBS spectra of dairy milk were compared. In addition, proteins and fat level in milks can be determined using molecular emissions such as CN bands. Ca concentrations were calculated to be 2.165 ± 0.203 g/L in 1% of dairy milk fat samples and 2.809 ± 0.172 g/L in 2% of dairy milk fat samples using the standard addition method (SAM) with LIBS spectra. Univariate and multivariate statistical analysis methods showed that the contents of major mineral elements were higher in lactose-free dairy milk than those in dairy milk. The principal component analysis (PCA) method was used to discriminate four milk samples depending on their mineral elements concentration. In addition, proteins and fat level in dairy milks were determined using molecular emissions such as CN band. We applied partial least squares regression (PLSR) and simple linear regression (SLR) models to predict levels of milk fat in dairy milk samples. The PLSR model was successfully used to predict levels of milk fat in dairy milk sample with the relative accuracy (RA%) less than 6.62% using CN (0,0) band.

  19. Entwicklung der Reglementierung von 10 MEM-Berufen im Kontext von Bildungsreformen und dem Wandel in der Arbeitswelt: Eine Kurzstudie im Auftrag von LIBS: Eine Kurzstudie im Auftrag von LIBS Industrielle Berufslehren Schweiz, Baden

    OpenAIRE

    Egg, Maria Esther; Renold, Ursula

    2015-01-01

    Im Auftrag der LIBS Industrielle Berufslehren Schweiz, hat die KOF die Entwicklung von 10 MEM1-Berufsbildern seit dem ersten Berufsbildungsgesetz dargestellt und diese eingebettet in eine kurze Zusammenfassung der wichtigsten Etappenschritte des Schweizer Berufsbildungssystems.

  20. The determination of V and Mo by dispersive liquid–liquid microextraction (DLLME) combined with laser-induced breakdown spectroscopy (LIBS)

    OpenAIRE

    Jesus, Amanda M. D. de; Aguirre Pastor, Miguel Ángel; Hidalgo Núñez, Montserrat; Canals Hernández, Antonio; Pereira-Filho, Edenir R.

    2014-01-01

    Laser-induced breakdown spectroscopy (LIBS) is a promising analytical technique with well-known advantages and limitations. However, despite its growing popularity, this technique has been applied mainly to solid samples and there have been a smaller number of studies devoted to liquid samples. This lack of studies is mainly due to experimental difficulties in the analysis of liquid matrices. Sensitivity can be improved and matrix effects minimized in the LIBS analysis of aqueous samples by u...

  1. Sclerotinia sclerotiorum (Lib.) de Bary: biology and molecular traits of a cosmopolitan pathogen

    NARCIS (Netherlands)

    Bolton, M.D.; Thomma, B.P.H.J.; Nelson, B.D.

    2006-01-01

    Sclerotinia sclerotiorum (Lib.) de Bary is a necrotrophic fungal pathogen causing disease in a wide range of plants. This review summarizes current knowledge of mechanisms employed by the fungus to parasitize its host with emphasis on biology, physiology and molecular aspects of pathogenicity. In

  2. Laser-induced breakdown spectroscopy (LIBS) to measure quantitatively soil carbon with emphasis on soil organic carbon. A review.

    Science.gov (United States)

    Senesi, Giorgio S; Senesi, Nicola

    2016-09-28

    Soil organic carbon (OC) measurement is a crucial factor for quantifying soil C pools and inventories and monitoring the inherent temporal and spatial heterogeneity and changes of soil OC content. These are relevant issues in addressing sustainable management of terrestrial OC aiming to enhance C sequestration in soil, thus mitigating the impact of increasing CO2 concentration in the atmosphere and related effects on global climate change. Nowadays, dry combustion by an elemental analyzer or wet combustion by dichromate oxidation of the soil sample are the most recommended and commonly used methods for quantitative soil OC determination. However, the unanimously recognized uncertainties and limitations of these classical laboursome methods have prompted research efforts focusing on the development and application of more advanced and appealing techniques and methods for the measurement of soil OC in the laboratory and possibly in situ in the field. Among these laser-induced breakdown spectroscopy (LIBS) has raised the highest interest for its unique advantages. After an introduction and a highlight of the LIBS basic principles, instrumentation, methodologies and supporting chemometric methods, the main body of this review provides an historical and critical overview of the developments and results obtained up-to-now by the application of LIBS to the quantitative measurement of soil C and especially OC content. A brief critical summary of LIBS advantages and limitations/drawbacks including some final remarks and future perspectives concludes this review. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Micro-Laser-Induced Breakdown Spectroscopy (Micro-LIBS) Study on Ancient Roman Mortars.

    Science.gov (United States)

    Pagnotta, Stefano; Lezzerini, Marco; Ripoll-Seguer, Laura; Hidalgo, Montserrat; Grifoni, Emanuela; Legnaioli, Stefano; Lorenzetti, Giulia; Poggialini, Francesco; Palleschi, Vincenzo

    2017-04-01

    The laser-induced breakdown spectroscopy (LIBS) technique was used for analyzing the composition of an ancient Roman mortar (5th century A.D.), exploiting an experimental setup which allows the determination of the compositions of binder and aggregate in few minutes, without the need for sample treatment. Four thousand LIBS spectra were acquired from an area of 10 mm 2 , with a 50 µm lateral resolution. The elements of interest in the mortar sample (H, C, O, Na, Mg, Al, Si, K, Ca, Ti, Mn, Fe) were detected and mapped. The collected data graphically shown as compositional images were interpreted using different statistical approaches for the determination of the chemical composition of the binder and aggregate fraction. The methods of false color imaging, blind separation, and self-organizing maps were applied and their results are discussed in this paper. In particular, the method based on the use of self-organizing maps gives well interpretable results in very short times, without any reduction in the dimensionality of the system.

  4. Determination of calcium to phosphate elemental ratio in natural hydroxypatite using LIBS

    Science.gov (United States)

    Mazalan, Elham; Chaudhary, Kashif; Haider, Zuhaib; Hadi, Siti Fatimah Abd; Ali, Jalil

    2018-05-01

    In this work, laser induced breakdown spectroscopy (LIBS) is employed for determination of calcium to phosphate (Ca/P) ratio in hydroxyapatite (HA) extracted from animal bones. HA was extracted from the biological bones of lamb, bovine, and fish separately. Fresh bones were boiled in deuterium-depleted water (DDW) for 4 hours and immersed it in acetone for 15 hours followed by drying process in the oven. Dried bones were heated at 600 °C and crushed into powder form which was then mixed with potassium bromide (KBr) in a known quantity. The mixture for each sample was palletized into pellets of identical mass using a hydraulic press. The palletized samples of HA extracted from the bones were ablated with 10 ns Q-switched Nd-YAG laser pulses having an energy of 320 mJ/pulse. The optical emissions produced from the laser induced plasma were recorded. Ca and P emission lines are identified and the Ca/P is calculated. Ca/P ratio by LIBS analysis has been verified by EDX measurements and are found in good agreement.

  5. Controlled laser cleaning of artworks via low resolution LIBS and linear correlation analysis

    NARCIS (Netherlands)

    Lentjes, M.; Dickmann, Klaus; Meijer, J.; Ostendof, A.; Hoult, A.; Lu, Y.

    2005-01-01

    Based on a fibre optic miniature spectrometer (spectral range 200-1100 nm, λ-resolution 2 nm) we have built up a LIBS-system (Laser Induced Breakdown Spectroscopy) for online monitoring during laser cleaning of artworks. This system is unsuitable for high resolved elemental identification but is

  6. Calibration Transfer in LIBS and Raman Spectroscopy for Planetary Applications

    Science.gov (United States)

    Dyar, M. D.; Thomas, B. F.; Parente, M.; Gemp, I.; Mullen, T. H.

    2017-12-01

    Planetary scientists rely on spectral libraries and instrument reproducibility to interpret results from missions. Major investments have been made into assembling libraries, but they often naively assume that spectra of single crystals versus powders and from varying instruments will be the same. Calibration transfer (CT) seeks to algorithmically resolve discrepancies among datasets from different instruments or conditions. It offers the ability to align suites of spectra with a small number of common samples, allowing better models to be built with combined data sets. LIBS and Raman data present different challenges for CT. Quantitative geochemical analyses by LIBS spectroscopy are limited by lack of consistency among repeated laser shots and across instruments. Many different factors affect the presence/absence of emission lines and their intensities, such as laser power/plasma temperature, angle of incidence, detector sensitivity/resolution. To overcome these, models in which disparate datasets are projected into a joint low-dimensional subspace where all data can be aligned before quantitative analysis, such as Correlation Analysis for Domain Adaptation (CADA), have proven very effective. They require some overlap between the populations of spectra to be aligned. For example, prediction of SiO2 on 80 samples from two different LIBS labs show errors of ±16-29 wt.% when the training and test sets have no overlap, and ±4.94 wt% SiO2 when CADA is used. Uncorrected Earth-Mars spectral differences are likely to cause errors with the same order of magnitude. As with other types of reflectance spectroscopy, Raman data are plagued by differences among single crystal/powder samples and laser wavelength that affect peak intensities, and by spectral offsets from instruments with varying resolution and wavenumber alignment schemes. These problems persist even within the archetypal RRUFF database. Pre-processing transformation functions such as optimized baseline removal

  7. A Deep Learning Approach to LIBS Spectroscopy for Planetary Applications

    Science.gov (United States)

    Mullen, T. H.; Parente, M.; Gemp, I.; Dyar, M. D.

    2017-12-01

    The ChemCam instrument on the Curiousity rover has collected >440,000 laser-induced breakdown spectra (LIBS) from 1500 different geological targets since 2012. The team is using a pipeline of preprocessing and partial least squares techniques to predict compositions of surface materials [1]. Unfortunately, such multivariate techniques are plagued by hard-to-meet assumptions involving constant hyperparameter tuning to specific elements and the amount of training data available; if the whole distribution of data is not seen, the method will overfit to the training data and generalizability will suffer. The rover only has 10 calibration targets on-board that represent a small subset of the geochemical samples the rover is expected to investigate. Deep neural networks have been used to bypass these issues in other fields. Semi-supervised techniques allow researchers to utilized small labeled datasets and vast amounts of unlabeled data. One example is the variational autoencoder model, a semi-supervised generative model in the form of a deep neural network. The autoencoder assumes that LIBS spectra are generated from a distribution conditioned on the elemental compositions in the sample and some nuisance. The system is broken into two models: one that predicts elemental composition from the spectra and one that generates spectra from compositions that may or may not be seen in the training set. The synthesized spectra show strong agreement with geochemical conventions to express specific compositions. The predictions of composition show improved generalizability to PLS. Deep neural networks have also been used to transfer knowledge from one dataset to another to solve unlabeled data problems. Given that vast amounts of laboratry LIBS spectra have been obtained in the past few years, it is now feasible train a deep net to predict elemental composition from lab spectra. Transfer learning (manifold alignment or calibration transfer) [2] is then used to fine-tune the model

  8. Multivariate innovative approaches to the treatment of the emission of LIBS plasmas. Application to chemical online analysis in a nuclear environment

    International Nuclear Information System (INIS)

    El-Rakwe, Maria

    2016-01-01

    Online and in situ analysis is now a strategic development for analytical chemistry. This is especially true in the nuclear field for which the security constraints related to the radioactivity of samples, and the need to minimize waste from analyzes argue for remote measurement techniques without sampling or sample preparation. Laser-Induced Breakdown Spectroscopy (LIBS) technique for elemental analysis of materials based on laser ablation and the optical emission spectroscopy, has these qualities. It is a technique of choice for online analysis. However, processes involved in LIBS, namely laser ablation, atomization, plasma formation and emission, are quite complex and difficult to control because the underlying physical phenomena are coupled and nonlinear. In addition, the analytical performance of the LIBS technique depends strongly on the choice of experimental conditions. Finally, an online analysis system should be as robust as possible face to uncontrolled variations in measurement conditions. The objective of this thesis is to improve control and performance of quantitative analysis by LIBS using multivariate methods capable of handling multi-dimensionality, nonlinearity and the coupling between parameters and data. For this, the work is divided into two parts. First the optimization is carried out using a central composite design to model the relationship between the experimental parameters of laser ablation (pulse energy and beam focusing parameters) and signal detection (delay time) to the physical characteristics of plasma (ablated mass, temperature) and the analytical performance (intensity and repeatability of the signal). The optimization parameters that results is then interpreted as the best compromise for the quantitative analysis between efficiency of laser ablation and plasma heating. Secondly, a multivariate methodology based on MCR-ALS, ICA and PLS techniques, was developed to quantify certain elements in different metallic matrices

  9. Investigation of non-uniformity and inclusions in 6LiInSe2 utilizing laser induced breakdown spectroscopy (LIBS)

    Science.gov (United States)

    Wiggins, Brenden; Tupitsyn, Eugene; Bhattacharya, Pijush; Rowe, Emmanuel; Lukosi, Eric; Chvala, Ondrej; Burger, Arnold; Stowe, Ashley

    2013-09-01

    Impurity analysis and compositional distribution studies have been conducted on a crystal of LiInSe2, a compound semiconductor which recently has been shown to respond to ionizing radiation. IR microscopy and laser induced breakdown spectroscopy (LIBS) revealed the presence of inclusions within the crystal lattice. These precipitates were revealed to be alkali and alkaline earth elemental impurities with non-uniform spatial distribution in the crystal. LIBS compositional maps correlate the presence of these impurities with visual color differences in the crystal as well as a significant shift of the band gap. Further, LIBS revealed variation in the ratio of I-III-VI2 elemental constituents throughout the crystal. Analysis of compositional variation and impurities will aid in discerning optimal synthesis and crystal growth parameters to maximize the mobility-lifetime product and charge collection efficiency in the LiInSe2 crystal. Preliminary charge trapping calculations have also been conducted with the Monte Carlo N-particle eXtended (MCNPx) package indicating preferential trapping of holes during irradiation with thermal neutrons.

  10. Le délibéré aux assises, ultime point aveugle dans l’affaire d’Outreau

    OpenAIRE

    Fayol-Noireterre, Jean-Marie

    2009-01-01

    Cet article envisage les délibérés des cours d’assises, en premier ressort et en appel, de l’affaire d’Outreau, à partir des auditions de la commission d’enquête parlementaire, et à la lumière d’une expérience professionnelle de magistrat (17 années comme juge des enfants, 16 années comme président d'assises). Cette libre projection permet de parcourir, à partir des textes de loi, des pratiques de conduites de délibérés. Il s'agit aussi d'aborder les problèmes inhérents au traitement judiciai...

  11. Libéralisation commerciale et pauvreté en Afrique | CRDI - Centre ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    25 mai 2010 ... Bien que le principal argument des partisans de la libéralisation commerciale soit les gains de bien-être, à l'échange, ceux-ci reconnaissent qu'il y a des gagnants et des perdants. Face à ce constat, la problématique de la répartition des gains de l'échange dans les pays en développement, où les ...

  12. Quantitative Analysis of KF-LiF-ZrF4 Molten Salt by Probe Assisted in-situ LIBS Systems

    International Nuclear Information System (INIS)

    Kim, S.H.; Moon, J.H.; Kim, D.H.; Hwang, I.S.; Lee, J.H.

    2015-01-01

    Full text of publication follows: Pyro-processing draws attention as a recycling process of spent nuclear fuel for future nuclear reactor. In the aspect of process control and safeguards of the pyro-processing, it requires a technology to measure the concentration of molten salt in real-time. The existing technologies measure the concentration by chemical analysis of sampled molten salt in the hot cell but it is disadvantageous in the aspects of cost, safety and time. The LIBS (Laser-Induced Breakdown Spectroscopy) is a form of atomic emission spectroscopy in which a pulsed laser is used as the excitation source. LIBS technology is appropriate to measure sensitive nuclear materials in hot cell because it is capable of measuring specimen quantitatively and qualitatively by exited atom by laser. Spectrum obtained from plasma is largely influenced by laser operation conditions and physical properties of specimens. Also, plasma induction is limited on the surface of specimen, so analysis of composition inside of the molten salt is extremely difficult. Thus, several restrictions should be overcome in order to apply LIBS for the measurement of molten salt (KF-LiF-ZrF 4 ) composition in real-time. In this study probe assisted LIBS system will be introduced with KF-LiF-ZrF 4 to quantitatively measure molten salt composition. Echelle spectrometer was used and the measurable wavelength area was 250-400 nm, the range of UV ray. NIST atomic spectra database measured the wavelength for molten salt composition, and each element was selected high signal intensity and wavelength range that is not overlapped by other elements. (authors)

  13. Satiation deficits and binge eating: Probing differences between bulimia nervosa and purging disorder using an ad lib test meal.

    Science.gov (United States)

    Keel, Pamela K; Haedt-Matt, Alissa A; Hildebrandt, Britny; Bodell, Lindsay P; Wolfe, Barbara E; Jimerson, David C

    2018-04-11

    Purging disorder (PD) has been included as a named condition within the DSM-5 category of Other Specified Feeding or Eating Disorder and differs from bulimia nervosa (BN) in the absence of binge-eating episodes. The current study evaluated satiation through behavioral and self-report measures to understand how this construct may explain distinct symptom presentations for bulimia nervosa (BN) and purging disorder (PD). Women (N = 119) were recruited from the community if they met DSM-5 criteria for BN (n = 57), PD (n = 31), or were free of eating pathology (n = 31 controls). Participants completed structured clinical interviews and questionnaires and an ad lib test meal during which they provided reports of subjective states. Significant group differences were found on self-reported symptoms, ad lib test meal intake, and subjective responses to food intake between individuals with eating disorders and controls and between BN and PD. Further, ad lib intake was associated with self-reported frequency and size of binge episodes. In a multivariable model, the amount of food consumed during binges as reported during clinical interviews predicted amount of food consumed during the ad lib test meal, controlling for other binge-related variables. Satiation deficits distinguish BN from PD and appear to be specifically linked to the size of binge episodes. Future work should expand exploration of physiological bases of these differences to contribute to novel interventions. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Measurement system for high-sensitivity LIBS analysis using ICCD camera in LabVIEW environment

    International Nuclear Information System (INIS)

    Zaytsev, S M; Popov, A M; Zorov, N B; Labutin, T A

    2014-01-01

    A measurement system based on ultrafast (up to 10 ns time resolution) intensified CCD detector ''Nanogate-2V'' (Nanoscan, Russia) was developed for high-sensitivity analysis by Laser-Induced Breakdown Spectrometry (LIBS). LabVIEW environment provided a high level of compatibility with variety of electronic instruments and an easy development of user interface, while Visual Studio environment was used for creation of LabVIEW compatible dll library with the use of ''Nanogate-2V'' SDK. The program for camera management and laser-induced plasma spectra registration was created with the use of Call Library Node in LabVIEW. An algorithm of integration of the second device ADC ''PCI-9812'' (ADLINK) to the measurement system was proposed and successfully implemented. This allowed simultaneous registration of emission and acoustic signals under laser ablation. The measured resolving power of spectrometer-ICCD system was equal to 12000 at 632 nm. An electron density of laser plasma was estimated with the use of H-α Balmer line. Steel spectra obtained at different delays were used for selection of the optimal conditions for manganese analytical signal registration. The feature of accumulation of spectra from several laser pulses was shown. The accumulation allowed reliable observation of silver signal at 328.07 nm in the LIBS spectra of soil (C Ag = 4.5 ppm). Finally, the correlation between acoustic and emission signals of plasma was found. Thus, technical possibilities of the developed LIBS system were demonstrated both for plasma diagnostics and analytical measurements

  15. Fast detection and characterization of organic and inorganic gunshot residues on the hands of suspects by CMV-GC-MS and LIBS.

    Science.gov (United States)

    Tarifa, Anamary; Almirall, José R

    2015-05-01

    A rapid method for the characterization of both organic and inorganic components of gunshot residues (GSR) is proposed as an alternative tool to facilitate the identification of a suspected shooter. In this study, two fast screening methods were developed and optimized for the detection of organic compounds and inorganic components indicative of GSR presence on the hands of shooters and non-shooters. The proposed methods consist of headspace extraction of volatile organic compounds using a capillary microextraction of volatiles (CMV) device previously reported as a high-efficiency sampler followed by detection by GC-MS. This novel sampling technique has the potential to yield fast results (LIBS) screening method for the detection of the inorganic components indicative of the presence of GSR (Sb, Pb and Ba) is described. The sampling method for the inorganics consists of liquid extraction of the target elements from the same cotton swabs (previously analyzed for VOCs) and an additional 30 swab samples followed by spiking 1μL of the extract solution onto a Teflon disk and then analyzed by LIBS. Advantages of LIBS include fast analysis (~12s per sample) and high selectivity and sensitivity, with expected LODs 0.1-18ng for each of the target elements after sampling. The analytical performance of the LIBS method is also compared to previously reported methods (inductively coupled plasma-optical emission spectroscopy). The combination of fast CMV sampling, unambiguous organic compound identification with GC-MS and fast LIBS analysis provides the basis for a new comprehensive screening method for GSR. Copyright © 2015 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  16. The Detection and Characterization of QoI-Resistant Didymella rabiei Causing Ascochyta Blight of Chickpea in Montana

    Directory of Open Access Journals (Sweden)

    Ayodeji S. Owati

    2017-06-01

    Full Text Available Ascochyta blight (AB of pulse crops (chickpea, field pea, and lentils causes yield loss in Montana, where 1.2 million acres was planted to pulses in 2016. Pyraclostrobin and azoxystrobin, quinone outside inhibitor (QoI fungicides, have been the choice of farmers for the management of AB in pulses. However, a G143A mutation in the cytochrome b gene has been reported to confer resistance to QoI fungicides. A total of 990 isolates of AB-causing fungi were isolated and screened for QoI resistance. Out of these, 10% were isolated from chickpea, 81% were isolated from field peas, and 9% isolated from lentil. These were from a survey of grower’s fields and seed lots (chickpea = 17, field pea = 131, and lentil = 21 from 23 counties in Montana sent to the Regional Pulse Crop Diagnostic Laboratory, Bozeman, MT, United States for testing. Fungicide-resistant Didymella rabiei isolates were found in one chickpea seed lot each sent from Daniels, McCone and Valley Counties, MT, from seed produced in 2015 and 2016. Multiple alignment analysis of amino acid sequences showed a missense mutation that replaced the codon for amino acid 143 from GGT to GCT, introducing an amino acid change from glycine to alanine (G143A, which is reported to be associated with QoI resistance. Under greenhouse conditions, disease severity was significantly higher on pyraclostrobin-treated chickpea plants inoculated with QoI-resistant isolates of D. rabiei than sensitive isolates (p-value = 0.001. This indicates that where resistant isolates are located, fungicide failures may be observed in the field. D. rabiei-specific polymerase chain reaction primer sets and hydrolysis probes were developed to efficiently discriminate QoI- sensitive and - resistant isolates.

  17. LibAnswers: Analyzing tickets (questions) to improve our library's virtual reference service(s)

    KAUST Repository

    Ramli, Rindra M.

    2017-05-01

    Analyze the questions received in LibAnswers (ticketing system) in order to improve the quality of our virtual reference services. Tickets that were received between June 2015 to April 2017 were analyzed and categorized. It was noted that most questions asked revolved around electronic resources issues as well as circulation/access issues.

  18. LibAnswers: Analyzing tickets (questions) to improve our library's virtual reference service(s)

    KAUST Repository

    Ramli, Rindra M.; Ba-Rayyan, Faten A.

    2017-01-01

    Analyze the questions received in LibAnswers (ticketing system) in order to improve the quality of our virtual reference services. Tickets that were received between June 2015 to April 2017 were analyzed and categorized. It was noted that most questions asked revolved around electronic resources issues as well as circulation/access issues.

  19. Éducation et Libération

    CERN Multimedia

    Education et Libération

    2013-01-01

    Vente d’artisanat du Tiers Monde Mardi 29 et mercredi 30 octobre 2013 CERN, Bâtiment principal Togo, Ecole Arc en ciel, construction des salles de classe. Appel pour le financement de ce chantier afin de libérer l’école de la charge des loyers payés pendant des années. Après nos réalisations en Amérique latine et au Bénin, nous mobilisons nos efforts pour l’école Arc en ciel de Kpeme, au Togo, sur les bords de l’Océan, à mi-chemin entre Lome et la frontière entre le Bénin et le Togo. Il s’agit d’une école primaire privée, laïque qui a très bonne réputation en termes de résultats, notamment pour les écoliers  en fin de scolarité primaire. Cela fait plusieurs années déjà q...

  20. A hybrid LIBS-Raman system combined with chemometrics: an efficient tool for plastic identification and sorting.

    Science.gov (United States)

    Shameem, K M Muhammed; Choudhari, Khoobaram S; Bankapur, Aseefhali; Kulkarni, Suresh D; Unnikrishnan, V K; George, Sajan D; Kartha, V B; Santhosh, C

    2017-05-01

    Classification of plastics is of great importance in the recycling industry as the littering of plastic wastes increases day by day as a result of its extensive use. In this paper, we demonstrate the efficacy of a combined laser-induced breakdown spectroscopy (LIBS)-Raman system for the rapid identification and classification of post-consumer plastics. The atomic information and molecular information of polyethylene terephthalate, polyethylene, polypropylene, and polystyrene were studied using plasma emission spectra and scattered signal obtained in the LIBS and Raman technique, respectively. The collected spectral features of the samples were analyzed using statistical tools (principal component analysis, Mahalanobis distance) to categorize the plastics. The analyses of the data clearly show that elemental information and molecular information obtained from these techniques are efficient for classification of plastics. In addition, the molecular information collected via Raman spectroscopy exhibits clearly distinct features for the transparent plastics (100% discrimination), whereas the LIBS technique shows better spectral feature differences for the colored samples. The study shows that the information obtained from these complementary techniques allows the complete classification of the plastic samples, irrespective of the color or additives. This work further throws some light on the fact that the potential limitations of any of these techniques for sample identification can be overcome by the complementarity of these two techniques. Graphical Abstract ᅟ.

  1. Diversité des théories libérales en Grèce au XIXe siècle

    Directory of Open Access Journals (Sweden)

    Roxane D. Argyropoulos

    2005-01-01

    Full Text Available Étudier l'émergence du mouvement libéral en Grèce au XIXe siècle implique une série de difficultés d'interprétation. C'est appréhender un univers qui a été légué par la Révolution française et nous conduit à l'acquisition de principes indispensables au fonctionnement d'une société démocratique moderne. Υ travers des types de discours différents, nous essayons de suivre les traces de cette mise en œuvre du principe de la liberté de 1830 jusqu'à la veille du premier conflit mondial. On assiste après 1830, à une période de transition mais également de mise en œuvre des idées novatrices des Lumières. Les libéraux grecs ont pris fait et cause pour des combats concernant le respect de la vie humaine, la réciprocité des droits et des devoirs et sont dominés par la préoccupation de la liberté d'expression et de création, l'abolition de la peine de mort, l'idéal républicain, l'instruction publique, le défi du progrès. Depuis les années 1830 jusqu'en 1870, se réclamer du libéralisme, c'est s'inscrire dans les forces progressistes. Mais, la dernière phase de son édification fut liée à la montée du socialisme et du marxisme, qu'il allait remettre en question, et dans les années qui ont suivi la défaite de 1897, le libéralisme est confronté à des théories comme la pensée polyvalente de Nietzsche. Dans les différentes phases de l'évolution de la pensée libérale en Grèce, on observe des variations qui pour la plupart sont des étapes du processus vers la démocratie.

  2. The role of nitric oxide in the interaction of Arabidopsis thaliana with the biotrophic fungi, Golovinomyces orontii and Erysiphe pisi

    Science.gov (United States)

    Schlicht, Markus; Kombrink, Erich

    2013-01-01

    Powdery mildews are a diverse group of pathogenic fungi that can infect a large number of plant species, including many economically important crops. However, basic and applied research on these devastating diseases has been hampered by the obligate biotrophic lifestyle of the pathogens, which require living host cells for growth and reproduction, and lacking genetic and molecular tools for important host plants. The establishment of Arabidopsis thaliana as a host of different powdery mildew species allowed pursuing new strategies to study the molecular mechanisms governing these complex plant–pathogen interactions. Nitric oxide (NO) has emerged as an important signaling molecule in plants, which is produced upon infection and involved in activation of plant immune responses. However, the source and pathway of NO production and its precise function in the regulatory network of reactions leading to resistance is still unknown. We studied the response of Arabidopsis thaliana to infection with the adapted powdery mildew, Golovinomyces orontii (compatible interaction) and the non-adapted, Erysiphe pisi (incompatible interaction). We observed that NO accumulated rapidly and transiently at infection sites and we established a correlation between the resistance phenotype and the amount and timing of NO production. Arabidopsis mutants with defective immune response accumulated lower NO levels compared to wild type. Conversely, increased NO levels, generated by treatment with chemicals or expression of a NO-synthesizing enzyme, resulted in enhanced resistance, but only sustained NO production prevented excessive leaf colonization by the fungus, which was not achieved by a short NO burst although this reduced the initial penetration success. By contrast, lowered NO levels did not impair the ultimate resistance phenotype. Although our results suggest a function of NO in mediating plant immune responses, a direct impact on pathogen growth and development cannot be excluded

  3. Dehydrated Carbon Coupled with Laser-Induced Breakdown Spectrometry (LIBS) for the Determination of Heavy Metals in Solutions.

    Science.gov (United States)

    Niu, Guanghui; Shi, Qi; Xu, Mingjun; Lai, Hongjun; Lin, Qingyu; Liu, Kunping; Duan, Yixiang

    2015-10-01

    In this article, a novel and alternative method of laser-induced breakdown spectroscopy (LIBS) analysis for liquid sample is proposed, which involves the removal of metal ions from a liquid to a solid substrate using a cost-efficient adsorbent, dehydrated carbon, obtained using a dehydration reaction. Using this new technique, researchers can detect trace metal ions in solutions qualitatively and quantitatively, and the drawbacks of performing liquid analysis using LIBS can be avoided because the analysis is performed on a solid surface. To achieve better performance using this technique, we considered parameters potentially influencing both adsorption performance and LIBS analysis. The calibration curves were evaluated, and the limits of detection obtained for Cu(2+), Pb(2+), and Cr(3+) were 0.77, 0.065, and 0.46 mg/L, respectively, which are better than those in the previous studies. In addition, compared to other absorbents, the adsorbent used in this technique is much cheaper in cost, easier to obtain, and has fewer or no other elements other than C, H, and O that could result in spectral interference during analysis. We also used the recommended method to analyze spiked samples, obtaining satisfactory results. Thus, this new technique is helpful and promising for use in wastewater analysis and management.

  4. [Influence of Spectral Pre-Processing on PLS Quantitative Model of Detecting Cu in Navel Orange by LIBS].

    Science.gov (United States)

    Li, Wen-bing; Yao, Lin-tao; Liu, Mu-hua; Huang, Lin; Yao, Ming-yin; Chen, Tian-bing; He, Xiu-wen; Yang, Ping; Hu, Hui-qin; Nie, Jiang-hui

    2015-05-01

    Cu in navel orange was detected rapidly by laser-induced breakdown spectroscopy (LIBS) combined with partial least squares (PLS) for quantitative analysis, then the effect on the detection accuracy of the model with different spectral data ptetreatment methods was explored. Spectral data for the 52 Gannan navel orange samples were pretreated by different data smoothing, mean centralized and standard normal variable transform. Then 319~338 nm wavelength section containing characteristic spectral lines of Cu was selected to build PLS models, the main evaluation indexes of models such as regression coefficient (r), root mean square error of cross validation (RMSECV) and the root mean square error of prediction (RMSEP) were compared and analyzed. Three indicators of PLS model after 13 points smoothing and processing of the mean center were found reaching 0. 992 8, 3. 43 and 3. 4 respectively, the average relative error of prediction model is only 5. 55%, and in one word, the quality of calibration and prediction of this model are the best results. The results show that selecting the appropriate data pre-processing method, the prediction accuracy of PLS quantitative model of fruits and vegetables detected by LIBS can be improved effectively, providing a new method for fast and accurate detection of fruits and vegetables by LIBS.

  5. Libéralisation du commerce des biens et services TIC : enjeux et ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Libéralisation du commerce des biens et services TIC : enjeux et implications pour la mise en oeuvre de politiques publiques en Afrique de l'Ouest. En Afrique de l'Ouest, les entreprises du secteur privé des technologies d'information et de la communication (TIC) ont démontré leur capacité à créer des emplois et à stimuler ...

  6. Mercury Amalgam Diffusion in Human Teeth Probed Using Femtosecond LIBS.

    Science.gov (United States)

    Bello, Liciane Toledo; da Ana, Patricia Aparecida; Santos, Dário; Krug, Francisco José; Zezell, Denise Maria; Vieira, Nilson Dias; Samad, Ricardo Elgul

    2017-04-01

    In this work the diffusion of mercury and other elements from amalgam tooth restorations through the surrounding dental tissue (dentin) was evaluated using femtosecond laser-induced breakdown spectroscopy (fs-LIBS). To achieve this, seven deciduous and eight permanent extracted human molar teeth with occlusal amalgam restorations were half-sectioned and analyzed using pulses from a femtosecond laser. The measurements were performed from the amalgam restoration along the amalgam/dentin interface to the apical direction. It was possible to observe the presence of metallic elements (silver, mercury, copper and tin) emission lines, as well as dental constituent ones, providing fingerprints of each material and comparable data for checking the consistence of the results. It was also shown that the elements penetration depth values in each tooth are usually similar and consistent, for both deciduous and permanent teeth, indicating that all the metals diffuse into the dentin by the same mechanism. We propose that this diffusion mechanism is mainly through liquid dragging inside the dentin tubules. The mercury diffused further in permanent teeth than in deciduous teeth, probably due to the longer diffusion times due to the age of the restorations. It was possible to conclude that the proposed femtosecond-LIBS system can detect the presence of metals in the dental tissue, among the tooth constituent elements, and map the distribution of endogenous and exogenous chemical elements, with a spatial resolution that can be brought under 100 µm.

  7. Characterization of laser-induced breakdown spectroscopy (LIBS) for application to space exploration

    International Nuclear Information System (INIS)

    Knight, Andrew K.; Scherbarth, Nancy L.; Cremers, David A.; Ferris, Monty J.

    2000-01-01

    Early in the next century, several space missions are planned with the goal of landing craft on asteroids, comets, the Moon, and Mars. To increase the scientific return of these missions, new methods are needed to provide (1) significantly more analyses per mission lifetime, and (2) expanded analytical capabilities. One method that has the potential to meet both of these needs for the elemental analysis of geological samples is laser-induced breakdown spectroscopy (LIBS). These capabilities are possible because the laser plasma provides rapid analysis and the laser pulse can be focused on a remotely located sample to perform a stand-off measurement. Stand-off is defined as a distance up to 20 m between the target and laser. Here we present the results of a characterization of LIBS for the stand-off analysis of soils at reduced air pressures and in a simulated Martian atmosphere (5-7 torr pressure of CO 2 ) showing the feasibility of LIBS for space exploration. For example, it is demonstrated that an analytically useful laser plasma can be generated at distances up to 19 m by using only 35 mJ/pulse from a compact laser. Some characteristics of the laser plasma at reduced pressure were also investigated. Temporally and spectrally resolved imaging showed significant changes in the plasma as the pressure was reduced and also showed that the analyte signals and mass ablated from a target were strongly dependent on pressure. As the pressure decreased from 590 torr to the 40-100 torr range, the signals increased by a factor of about 3-4, and as the pressure was further reduced the signals decreased. This behavior can be explained by pressure-dependent changes in the mass of material vaporized and the frequency of collisions between species in the plasma. Changes in the temperature and the electron density of the plasmas with pressure were also examined and detection limits for selected elements were determined. (c) 2000 Society for Applied Spectroscopy

  8. Characterization of laser-induced breakdown spectroscopy (LIBS) for application to space exploration

    Energy Technology Data Exchange (ETDEWEB)

    Knight, Andrew K. [Group CST-1, MS J565, Chemical Science and Technology Division, Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Scherbarth, Nancy L. [Group CST-1, MS J565, Chemical Science and Technology Division, Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Cremers, David A. [Group CST-1, MS J565, Chemical Science and Technology Division, Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Ferris, Monty J. [Group CST-1, MS J565, Chemical Science and Technology Division, Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States)

    2000-03-01

    Early in the next century, several space missions are planned with the goal of landing craft on asteroids, comets, the Moon, and Mars. To increase the scientific return of these missions, new methods are needed to provide (1) significantly more analyses per mission lifetime, and (2) expanded analytical capabilities. One method that has the potential to meet both of these needs for the elemental analysis of geological samples is laser-induced breakdown spectroscopy (LIBS). These capabilities are possible because the laser plasma provides rapid analysis and the laser pulse can be focused on a remotely located sample to perform a stand-off measurement. Stand-off is defined as a distance up to 20 m between the target and laser. Here we present the results of a characterization of LIBS for the stand-off analysis of soils at reduced air pressures and in a simulated Martian atmosphere (5-7 torr pressure of CO{sub 2}) showing the feasibility of LIBS for space exploration. For example, it is demonstrated that an analytically useful laser plasma can be generated at distances up to 19 m by using only 35 mJ/pulse from a compact laser. Some characteristics of the laser plasma at reduced pressure were also investigated. Temporally and spectrally resolved imaging showed significant changes in the plasma as the pressure was reduced and also showed that the analyte signals and mass ablated from a target were strongly dependent on pressure. As the pressure decreased from 590 torr to the 40-100 torr range, the signals increased by a factor of about 3-4, and as the pressure was further reduced the signals decreased. This behavior can be explained by pressure-dependent changes in the mass of material vaporized and the frequency of collisions between species in the plasma. Changes in the temperature and the electron density of the plasmas with pressure were also examined and detection limits for selected elements were determined. (c) 2000 Society for Applied Spectroscopy.

  9. Monitoring uranium, hydrogen, and lithium and their isotopes using a compact laser-induced breakdown spectroscopy (LIBS) probe and high-resolution spectrometer.

    Science.gov (United States)

    Cremers, David A; Beddingfield, Alan; Smithwick, Robert; Chinni, Rosemarie C; Jones, C Randy; Beardsley, Burt; Karch, Larry

    2012-03-01

    The development of field-deployable instruments to monitor radiological, nuclear, and explosive (RNE) threats is of current interest for a number of assessment needs such as the on-site screening of suspect facilities and nuclear forensics. The presence of uranium and plutonium and radiological materials can be determined through monitoring the elemental emission spectrum using relatively low-resolution spectrometers. In addition, uranium compounds, explosives, and chemicals used in nuclear fuel processing (e.g., tributyl-phosphate) can be identified by applying chemometric analysis to the laser-induced breakdown (LIBS) spectrum recorded by these spectrometers. For nuclear forensic applications, however, isotopes of U and Pu and other elements (e.g., H and Li) must also be determined, requiring higher resolution spectrometers given the small magnitude of the isotope shifts for some of these elements (e.g., 25 pm for U and 13 pm for Pu). High-resolution spectrometers will be preferred for several reasons but these must fit into realistic field-based analysis scenarios. To address the need for field instrumentation, we evaluated a previously developed field-deployable hand-held LIBS interrogation probe combined with two relatively new high-resolution spectrometers (λ/Δλ ~75,000 and ~44,000) that have the potential to meet field-based analysis needs. These spectrometers are significantly smaller and lighter in weight than those previously used for isotopic analysis and one unit can provide simultaneous wide spectral coverage and high resolution in a relatively small package. The LIBS interrogation probe was developed initially for use with low resolution compact spectrometers in a person-portable backpack LIBS instrument. Here we present the results of an evaluation of the LIBS probe combined with a high-resolution spectrometer and demonstrate rapid detection of isotopes of uranium and hydrogen and highly enriched samples of (6)Li and (7)Li. © 2012 Society for

  10. Superhumps linked to X-ray emission. The superoutbursts of SSS J122221.7-311525 and GW Lib

    Science.gov (United States)

    Neustroev, V. V.; Page, K. L.; Kuulkers, E.; Osborne, J. P.; Beardmore, A. P.; Knigge, C.; Marsh, T.; Suleimanov, V. F.; Zharikov, S. V.

    2018-03-01

    Context. We present more than 4 years of Swift X-ray observations of the 2013 superoutburst, subsequent decline and quiescence of the WZ Sge-type dwarf nova SSS J122221.7-311525 (SSS J122222) from 6 days after discovery. Aims: Only a handful of WZ Sge-type dwarf novae have been observed in X-rays, and until recently GW Lib was the only binary of this type with complete coverage of an X-ray light curve throughout a superoutburst. We collected extensive X-ray data of a second such system to understand the extent to which the unexpected properties of GW Lib are common to the WZ Sge class. Methods: We collected 60 Swift-XRT observations of SSS J122222 between 2013 January 6 and 2013 July 1. Four follow-up observations were performed in 2014, 2015, 2016 and 2017. The total exposure time of our observations is 86.6 ks. We analysed the X-ray light curve and compared it with the behaviour of superhumps which were detected in the optical light curve. We also performed spectral analysis of the data. The results were compared with the properties of GW Lib, for which new X-ray observations were also obtained. Results: SSS J122222 was variable and around five times brighter in 0.3-10 keV X-rays during the superoutburst than in quiescence, mainly because of a significant strengthening of a high-energy component of the X-ray spectrum. The post-outburst decline of the X-ray flux lasted at least 500 d. The data show no evidence of the expected optically thick boundary layer in the system during the outburst. SSS J122222 also exhibited a sudden X-ray flux change in the middle of the superoutburst, which occurred exactly at the time of the superhump stage transition. A similar X-ray behaviour was also detected in GW Lib. Conclusions: We show that the X-ray flux exhibits changes at the times of changes in the superhump behaviour of both SSS J122222 and GW Lib. This result demonstrates a relationship between the outer disc and the white dwarf boundary layer for the first time, and

  11. Usability Testing, User-Centered Design, and LibGuides Subject Guides: A Case Study

    Science.gov (United States)

    Sonsteby, Alec; DeJonghe, Jennifer

    2013-01-01

    Usability testing has become a routine way for many libraries to ensure that their Web presence is user-friendly and accessible. At the same time, popular subject guide creation systems, such as LibGuides, decentralize Web content creation and put authorship into the hands of librarians who may not be trained in user-centered design principles. At…

  12. L'institutionnalisation des délibérations dans l'espace public au sein ...

    African Journals Online (AJOL)

    seriane.camara

    16 sept. 2010 ... prise de décision occuperont une place importante dans cette étude, l'accent sera surtout mis sur le processus par lequel la délibération dans l' ...... autorités traditionnelles mettent en œuvre pour essayer de faire face aux.

  13. Sausage instability of Z-discharged plasma channel in LIB-fusion device

    International Nuclear Information System (INIS)

    Murakami, H.; Kawata, S.; Niu, K.

    1982-07-01

    Current-carring plasma channels have been proposed for transporting intense ion beams from diodes to a target in a LIB-fusion device. In this paper, the growth rate of the most dangerous surface mode, that is, axisymmetric sausage instability is examined for the plasma channel. The growth rate is shown to be smaller than that of the plasma channel with no fluid motion in a sharp boundary. It is concluded that the stable plasma channel can be formed. (author)

  14. Calibrating the ChemCam LIBS for Carbonate Minerals on Mars

    Science.gov (United States)

    Wiens, Roger C.; Clegg, Samuel M.; Ollila, Ann M.; Barefield, James E.; Lanza, Nina; Newsom, Horton E.

    2009-01-01

    The ChemCam instrument suite on board the NASA Mars Science Laboratory (MSL) rover includes the first LIBS instrument for extraterrestrial applications. Here we examine carbonate minerals in a simulated martian environment using the LIDS technique in order to better understand the in situ signature of these materials on Mars. Both chemical composition and rock type are determined using multivariate analysis (MVA) techniques. Composition is confirmed using scanning electron microscopy (SEM) techniques. Our initial results suggest that ChemCam can recognize and differentiate between carbonate materials on Mars.

  15. The 1064 nm laser-induced breakdown spectroscopy (LIBS) inspection to detect the nutrient elements in freshly cut carrot samples

    Science.gov (United States)

    Yudasari, N.; Prasetyo, S.; Suliyanti, M. M.

    2018-03-01

    The laser-induced breakdown spectroscopy (LIBS) technique was applied to detect the nutrient elements contained in fresh carrot. Nd:YAG laser the wavelength of 1064 nm was employed in the experiments for ablation. Employing simple set-up of LIBS and preparing the sample with less step method, we are able to detect 18 chemical elements including some fundamental element of carrot, i.e Mg, Al, Fe, Mn, Ti, Ca, and Mn. By applying normalized profiles calculation on some of the element, we are able to compare the concentration level of each element of the outer and inner part of carrot.

  16. Remote Raman - laser induced breakdown spectroscopy (LIBS) geochemical investigation under Venus atmospheric conditions

    Energy Technology Data Exchange (ETDEWEB)

    Clegg, Sanuel M [Los Alamos National Laboratory; Barefield, James E [Los Alamos National Laboratory; Humphries, Seth D [Los Alamos National Laboratory; Wiens, Roger C [Los Alamos National Laboratory; Vaniman, D. T. [Los Alamos National Laboratory; Sharma, S. K. [UNIV OF HAWAII; Misra, A. K. [UNIV OF HAWAII; Dyar, M. D. [MT. HOLYOKE COLLEGE; Smrekar, S. E. [JET PROPULSION LAB.

    2010-12-13

    The extreme Venus surface temperatures ({approx}740 K) and atmospheric pressures ({approx}93 atm) create a challenging environment for surface missions. Scientific investigations capable of Venus geochemical observations must be completed within hours of landing before the lander will be overcome by the harsh atmosphere. A combined remote Raman - LIBS (Laser Induced Breakdown Spectroscopy) instrument is capable of accomplishing the geochemical science goals without the risks associated with collecting samples and bringing them into the lander. Wiens et al. and Sharma et al. demonstrated that both analytical techniques can be integrated into a single instrument capable of planetary missions. The focus of this paper is to explore the capability to probe geologic samples with Raman - LIBS and demonstrate quantitative analysis under Venus surface conditions. Raman and LIBS are highly complementary analytical techniques capable of detecting both the mineralogical and geochemical composition of Venus surface materials. These techniques have the potential to profoundly increase our knowledge of the Venus surface composition, which is currently limited to geochemical data from Soviet Venera and VEGA landers that collectively suggest a surface composition that is primarily tholeiitic basaltic with some potentially more evolved compositions and, in some locations, K-rich trachyandesite. These landers were not equipped to probe the surface mineralogy as can be accomplished with Raman spectroscopy. Based on the observed compositional differences and recognizing the imprecise nature of the existing data, 15 samples were chosen to constitute a Venus-analog suite for this study, including five basalts, two each of andesites, dacites, and sulfates, and single samples of a foidite, trachyandesite, rhyolite, and basaltic trachyandesite under Venus conditions. LIBS data reduction involved generating a partial least squares (PLS) model with a subset of the rock powder standards to

  17. Updates of the KArLE Experiment: New Libs Calibration Under High Vacuum for the Quantification of Potassium in Basalt for In Situ Geochronology

    Science.gov (United States)

    Devismes, D.; Cohen, B. A.; Li, Z.-H.; Miller, J. S.

    2014-01-01

    In planetary exploration, in situ absolute geochronology is one of the main important measurements that needs to be accomplished. Until now, on Mars, the age of the surface is only determined by crater density counting, which gives relative ages. These ages can have a lot of uncertainty as they depend on many parameters. More than that, the curves must be ties to absolute ages. Thus far, only the lost lander Beagle 2 was designed to conduct absolute geochronology measurements, though some recent attempts using MSL Curiosity show that this investigation is feasible and should be strongly encouraged for future flight. Experimental: The Potassium (K)-Argon Laser Experiment (KArLE) is being developed at MSFC through the NASA Planetary Instrument Definition and Development Program (PIDDP). The goal of this experiment is to provide in situ geochronology based on the K-Ar method. A laser ablates a rock under high vacuum, creating a plasma which is sensed by an optical spectrometer to do Laser Induced Breakdown Spectroscopy (LIBS). The ablated material frees gases, including radiogenic 40Ar,which is measured by a mass spectrometer (MS). As the potassium is a content and the 40Ar is a quantity, the ablated mass needed in order to relate them. The mass is given by the product of the ablated volume by the density of this material. So we determine the mineralogy of the ablated material with the LIBS spectra and images and calculate its density. The volume of the pit is measured by using microscopy. LIBS measurement of K under high vacuum: Three independant projects [1, 2, 3] including KArLE, are developing geochronological instruments based on this LA-LIBS-MS method. Despite several differences in their setup, all of them have validated the methods with analyses and ages. However, they all described difficulties with the LIBS measurements of K [3,4]. At ambient pressure, the quantification of K by LIBS on geological materials can be accurate [5]. However the protocol of the LA-LIBS

  18. Monitoring of heavy metal particle emission in the exhaust duct of a foundry using LIBS

    International Nuclear Information System (INIS)

    Dutouquet, C.; Le Bihan, O.; Dermigny, A.; Frejafon, E.; Gallou, G.; Sirven, J.B.; Torralba, B.

    2014-01-01

    Heavy metals have long been known to be detrimental to human health and the environment.Their emission is mainly considered to occur via the atmospheric route. Most of airborne heavy metals are of anthropogenic origin and produced through combustion processes at industrial sites such as incinerators and foundries. Current regulations impose threshold limits on heavy metal emissions. The reference method currently implemented for quantitative measurements at exhaust stacks consists of on-site sampling of heavy metals on filters for the particulate phase (the most prominent and only fraction considered in this study) prior to subsequent laboratory analysis. Results are therefore known only a few days after sampling. Stiffer regulations require the development of adapted tools allowing automatic, on-site or even in-situ measurements with temporal resolutions. The Laser-Induced Breakdown Spectroscopy (LIBS) technique was deemed as a potential candidate to meet these requirements. On site experiments were run by melting copper bars and monitoring emission of this element in an exhaust duct at a pilot-scale furnace in a French research center dedicated to metal casting. Two approaches designated as indirect and direct analysis were broached in these experiments. The former corresponds to filter enrichment prior to subsequent LIBS interrogation whereas the latter entails laser focusing right through the aerosol for detection. On-site calibration curves were built and compared with those obtained at laboratory scale in order to investigate possible matrix and analyte effects. Eventually, the obtained results in terms of detection limits and quantitative temporal monitoring of copper emission clearly emphasize the potentialities of the direct LIBS measurements. (authors)

  19. Répercussions de la libéralisation du commerce des services sur le ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Répercussions de la libéralisation du commerce des services sur le développement. La documentation économique a démontré l'importance du secteur des services dans le processus de croissance économique et de développement social. Le principal défi auquel sont confrontés aujourd'hui les pays en développement ...

  20. 'CM 88' - A multiple disease resistant chickpea mutant variety

    International Nuclear Information System (INIS)

    Haq, M.A.; Hassan, Mahmudul; Sadiq, M.

    2001-01-01

    Full text: Chickpea is the most important grain legume crop of Pakistan. Ascochyta blight (Ascochyta rabiei) and Fusarium wilt (Fusarium oxysporum F. sp cicer) are most serious diseases, having the potential to devastate a crop. A multiple disease resistant and high yielding mutant CM 88 has been developed through 100 Gy gamma irradiation treatment of variety 'C 727'. This was once a widely grown and popular variety, which lost its resistance to Ascochyta and was replaced. The selection of mutants was performed in the M2 generation grown in the Ascochyta blight nursery and sixteen mutants were selected. In the subsequent generations CM 88 proved resistant to both Ascochyta blight and Fusarium wilt, and exhibited superiority in agronomic characteristics. CM 88 was also tested for many years in the various yield trials on research stations and farmers fields throughout the country. In these trials it out yielded both the parent and standard varieties. The mutant CM 88 has been approved by the Punjab Seed Council on 27 October 1994 for general cultivation in the Punjab Province, especially the Thal area which accounts for more than 70% of the area under chickpea cultivation. (author)

  1. La libéralisation comme source du dérèglement des transports ...

    African Journals Online (AJOL)

    Mots clés: Libéralisation - Transport public - Chronologie - Urbain - Organisation. English Title: Liberalization as a source of deregulation of public transport in Annaba city. English Abstract. Similarly at almost of the Algerian cities, after the dissolution of the Municipal Board RMCA, the city of Annaba doesn't escape from the ...

  2. Recent advances in the use of laser-induced breakdown spectroscopy (LIBS) as a rapid point-of-care pathogen diagnostic

    Science.gov (United States)

    Rehse, Steven J.; Miziolek, Andrzej W.

    2012-06-01

    Laser-induced breakdown spectroscopy (LIBS) has made tremendous progress in becoming a viable technology for rapid bacterial pathogen detection and identification. The significant advantages of LIBS include speed (present the latest advances achieved in LIBS-based bacterial sensing including the ability to uniquely identify species from more than five bacterial genera with high-sensitivity and specificity. Bacterial identifications are completely unaffected by environment, nutrition media, or state of growth and accurate diagnoses can be made on autoclaved or UV-irradiated specimens. Efficient discrimination of bacteria at the strain level has been demonstrated. A rapid urinary tract infection diagnosis has been simulated with no sample preparation and a one second diagnosis of a pathogen surrogate has been demonstrated using advanced chemometric analysis with a simple "stop-light" user interface. Stand-off bacterial identification at a 20-m distance has been demonstrated on a field-portable instrument. This technology could be implemented in doctors' offices, clinics, or hospital laboratories for point-of-care medical specimen analysis; mounted on military medical robotic platforms for in-the- field diagnostics; or used in stand-off configuration for remote sensing and detection.

  3. Classification of red wine based on its protected designation of origin (PDO) using Laser-induced Breakdown Spectroscopy (LIBS).

    Science.gov (United States)

    Moncayo, S; Rosales, J D; Izquierdo-Hornillos, R; Anzano, J; Caceres, J O

    2016-09-01

    This work reports on a simple and fast classification procedure for the quality control of red wines with protected designation of origin (PDO) by means of Laser Induced Breakdown Spectroscopy (LIBS) technique combined with Neural Networks (NN) in order to increase the quality assurance and authenticity issues. A total of thirty-eight red wine samples from different PDO were analyzed to detect fake wines and to avoid unfair competition in the market. LIBS is well known for not requiring sample preparation, however, in order to increase its analytical performance a new sample preparation treatment by previous liquid-to-solid transformation of the wine using a dry collagen gel has been developed. The use of collagen pellets allowed achieving successful classification results, avoiding the limitations and difficulties of working with aqueous samples. The performance of the NN model was assessed by three validation procedures taking into account their sensitivity (internal validation), generalization ability and robustness (independent external validation). The results of the use of a spectroscopic technique coupled with a chemometric analysis (LIBS-NN) are discussed in terms of its potential use in the food industry, providing a methodology able to perform the quality control of alcoholic beverages. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Laser-induced breakdown spectroscopy (LIBS), part I: review of basic diagnostics and plasma-particle interactions: still-challenging issues within the analytical plasma community.

    Science.gov (United States)

    Hahn, David W; Omenetto, Nicoló

    2010-12-01

    Laser-induced breakdown spectroscopy (LIBS) has become a very popular analytical method in the last decade in view of some of its unique features such as applicability to any type of sample, practically no sample preparation, remote sensing capability, and speed of analysis. The technique has a remarkably wide applicability in many fields, and the number of applications is still growing. From an analytical point of view, the quantitative aspects of LIBS may be considered its Achilles' heel, first due to the complex nature of the laser-sample interaction processes, which depend upon both the laser characteristics and the sample material properties, and second due to the plasma-particle interaction processes, which are space and time dependent. Together, these may cause undesirable matrix effects. Ways of alleviating these problems rely upon the description of the plasma excitation-ionization processes through the use of classical equilibrium relations and therefore on the assumption that the laser-induced plasma is in local thermodynamic equilibrium (LTE). Even in this case, the transient nature of the plasma and its spatial inhomogeneity need to be considered and overcome in order to justify the theoretical assumptions made. This first article focuses on the basic diagnostics aspects and presents a review of the past and recent LIBS literature pertinent to this topic. Previous research on non-laser-based plasma literature, and the resulting knowledge, is also emphasized. The aim is, on one hand, to make the readers aware of such knowledge and on the other hand to trigger the interest of the LIBS community, as well as the larger analytical plasma community, in attempting some diagnostic approaches that have not yet been fully exploited in LIBS.

  5. Enhancement of laser-induced breakdown spectroscopy (LIBS) Detection limit using a low-pressure and short-pulse laser-induced plasma process.

    Science.gov (United States)

    Wang, Zhen Zhen; Deguchi, Yoshihiro; Kuwahara, Masakazu; Yan, Jun Jie; Liu, Ji Ping

    2013-11-01

    Laser-induced breakdown spectroscopy (LIBS) technology is an appealing technique compared with many other types of elemental analysis because of the fast response, high sensitivity, real-time, and noncontact features. One of the challenging targets of LIBS is the enhancement of the detection limit. In this study, the detection limit of gas-phase LIBS analysis has been improved by controlling the pressure and laser pulse width. In order to verify this method, low-pressure gas plasma was induced using nanosecond and picosecond lasers. The method was applied to the detection of Hg. The emission intensity ratio of the Hg atom to NO (IHg/INO) was analyzed to evaluate the LIBS detection limit because the NO emission (interference signal) was formed during the plasma generation and cooling process of N2 and O2 in the air. It was demonstrated that the enhancement of IHg/INO arose by decreasing the pressure to a few kilopascals, and the IHg/INO of the picosecond breakdown was always much higher than that of the nanosecond breakdown at low buffer gas pressure. Enhancement of IHg/INO increased more than 10 times at 700 Pa using picosecond laser with 35 ps pulse width. The detection limit was enhanced to 0.03 ppm (parts per million). We also saw that the spectra from the center and edge parts of plasma showed different features. Comparing the central spectra with the edge spectra, IHg/INO of the edge spectra was higher than that of the central spectra using the picosecond laser breakdown process.

  6. A study of using femtosecond LIBS in analyzing metallic thin film-semiconductor interface

    Science.gov (United States)

    Galmed, A. H.; Kassem, A. K.; von Bergmann, H.; Harith, M. A.

    2011-01-01

    Metals and metal alloys are usually employed as interconnections to guide electrical signals between components into the very large scale integrated (VLSI) devices. These devices demand higher complexity, better performance and lower cost. Thin film is a common geometry for these metallic applications, requiring a substrate for rigidity. Accurate depth profile analysis of coatings is becoming increasingly important with expanding industrial use in technological fields. A number of articles devoted to LIBS applications for depth-resolved analysis have been published in recent years. In the present work, we are studying the ability of femtosecond LIBS to make depth profiling for a Ti thin film of thickness 213 nm deposited onto a silicon (100) substrate before and after thermal annealing. The measurements revealed that an average ablation rates of 15 nm per pulse have been achieved. The thin film was examined using X-Ray Diffraction (XRD) and Atomic Force Microscope (AFM), while the formation of the interface was examined using Rutherford Back Scattering (RBS) before and after annealing. To verify the depth profiling results, a theoretical simulation model is presented that gave a very good agreement with the experimental results.

  7. Design and development of a LIBS system on linear plasma device PSI-2 for in situ real-time diagnostics of plasma-facing materials

    Directory of Open Access Journals (Sweden)

    X. Jiang

    2017-08-01

    Full Text Available Laser induced breakdown spectroscopy (LIBS is a strong candidate for detecting and monitoring the H/D/T content on the surface of plasma facing components (PFCs due to its capability of fast direct in situ measurement in extreme environment (e.g., vacuum, magnetic field, long distance, complex geometry. To study the feasibilities and encounter the challenges of LIBS on plasma devices, a LIBS system has been set up on the linear plasma device PSI-2. A number of key parameters including laser energy, the influence of magnetic field and the persistence of laser induced plasma are studied. Real-time measurements of deuterium outgassing on tungsten samples exposed to deuterium plasma of 1025 D/m2 are performed in the first 40–130 min after plasma exposure. The experimental results are compared to the calculations in the literature.

  8. Control of seed-borne pathogens on legumes by microbial and other alternative seed treatments

    NARCIS (Netherlands)

    Tinivella, F.; Hirata, L.M.; Celan, M.A.; Wright, S.A.I.; Amein, T.; Schmitt, A.; Wolf, van der J.M.; Koch, E.; Groot, S.P.C.

    2009-01-01

    Greenhouse trials were carried out in order to test the efficacy of different seed treatments as alternatives to chemicals against Colletotrichum lindemuthianum cause of anthracnose on bean and Ascochyta spp. cause of Ascochyta blights on pea, respectively. Resistance inducers, commercially

  9. Analisi sui pigmenti di ceramica neolitica tramite tecniche Raman e LIBS

    Directory of Open Access Journals (Sweden)

    Cristina Fabbri

    2007-04-01

    Full Text Available I dati presentati in questo breve contributo provengono da uno studio condotto in collaborazione dal Dipartimento di Scienze Archeologiche dell’Università di Pisa e dall’Istituto per i Processi Chimico-Fisici di Fisica molecolare del CNR di Pisa. Le metodologie applicate sono basate sull’analisi integrata delle tecniche spettroscopiche Raman e LIBS già ampiamente utilizzate nel campo dei Beni Culturali; i metodi sono infatti essenzialmente non distruttivi, non richiedono di un pre trattamento del campione e l’acquisizione delle misure è immediata.

  10. Laser-Induced Breakdown Spectroscopy (LIBS) for Monitoring the Formation of Hydroxyapatite Porous Layers

    OpenAIRE

    Sola, Daniel; Paulés, Daniel; Grima, Lorena; Anzano, Jesús

    2017-01-01

    Laser-induced breakdown spectroscopy (LIBS) is applied to characterize the formation of porous hydroxyapatite layers on the surface of 0.8CaSiO3-0.2Ca3(PO4)2 biocompatible eutectic glass immersed in simulated body fluid (SBF). Compositional and structural characterization analyses were also conducted by field emission scanning electron microscopy (FESEM), energy dispersive X-ray spectroscopy (EDX), and micro-Raman spectroscopy.

  11. Effect of Sample Preparation on the Discrimination of Bacterial Isolates Cultured in Liquid Nutrient Media Using Laser-Induced Breakdown Spectroscopy (LIBS).

    Science.gov (United States)

    Gamble, Gary R; Park, Bosoon; Yoon, Seung-Chul; Lawrence, Kurt C

    2016-03-01

    Laser-induced breakdown spectroscopy (LIBS) is used as the basis for discrimination between two genera of gram-negative bacteria and two genera of gram-positive bacteria representing pathogenic threats commonly found in poultry processing rinse waters. Because LIBS-based discrimination relies primarily upon the relative proportions of inorganic cell components including Na, K, Mg, and Ca, this study aims to determine the effects of trace mineral content and pH found in the water source used to isolate the bacteria upon the reliability of the resulting discriminant analysis. All four genera were cultured using tryptic soy agar (TSA) as the nutrient medium, and were grown under identical environmental conditions. The only variable introduced is the source water used to isolate the cultured bacteria. Cultures of each bacterium were produced using deionized (DI) water under two atmosphere conditions, reverse osmosis (RO) water, tap water, phosphate buffered saline (PBS) water, and TRIS buffered water. After 3 days of culture growth, the bacteria were centrifuged and washed three times in the same water source. Bacteria were then freeze dried, mixed with microcrystalline cellulose, and a pellet was made for LIBS analysis. Principal component analysis (PCA) was used to extract related variations in LIBS spectral data among the four bacteria genera and six water types used to isolate the bacteria, and Mahalanobis discriminant analysis (MDA) was used for classification. Results indicate not only that the four genera can be discriminated from each other in each water type, but that each genus can be discriminated by water type used for isolation. It is concluded that in order for LIBS to be a reliable and repeatable method for discrimination of bacteria grown in liquid nutrient media, care must be taken to insure that the water source used in purification of the culture be precisely controlled regarding pH, ionic strength, and proportionate amounts of mineral cations

  12. Using Localized Survey Items to Augment Standardized Benchmarking Measures: A LibQUAL+[TM] Study

    Science.gov (United States)

    Thompson, Bruce; Cook, Colleen; Kyrillidou, Martha

    2006-01-01

    The LibQUAL+[TM] protocol solicits open-ended comments from users with regard to library service quality, gathers data on 22 core items, and, at the option of individual libraries, also garners ratings on five items drawn from a pool of more than 100 choices selected by libraries. In this article, the relationship of scores on these locally…

  13. Monitoring of heavy metal particle emission in the exhaust duct of a foundry using LIBS.

    Science.gov (United States)

    Dutouquet, C; Gallou, G; Le Bihan, O; Sirven, J B; Dermigny, A; Torralba, B; Frejafon, E

    2014-09-01

    Heavy metals have long been known to be detrimental to human health and the environment. Their emission is mainly considered to occur via the atmospheric route. Most of airborne heavy metals are of anthropogenic origin and produced through combustion processes at industrial sites such as incinerators and foundries. Current regulations impose threshold limits on heavy metal emissions. The reference method currently implemented for quantitative measurements at exhaust stacks consists of on-site sampling of heavy metals on filters for the particulate phase (the most prominent and only fraction considered in this study) prior to subsequent laboratory analysis. Results are therefore known only a few days after sampling. Stiffer regulations require the development of adapted tools allowing automatic, on-site or even in-situ measurements with temporal resolutions. The Laser-Induced Breakdown Spectroscopy (LIBS) technique was deemed as a potential candidate to meet these requirements. On site experiments were run by melting copper bars and monitoring emission of this element in an exhaust duct at a pilot-scale furnace in a French research center dedicated to metal casting. Two approaches designated as indirect and direct analysis were broached in these experiments. The former corresponds to filter enrichment prior to subsequent LIBS interrogation whereas the latter entails laser focusing right through the aerosol for detection. On-site calibration curves were built and compared with those obtained at laboratory scale in order to investigate possible matrix and analyte effects. Eventually, the obtained results in terms of detection limits and quantitative temporal monitoring of copper emission clearly emphasize the potentialities of the direct LIBS measurements. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. First measurements of LIBS in the Zr-Nb system

    International Nuclear Information System (INIS)

    Previtali, E; Ararat, C; Corvalan, C; Iribarren, M

    2012-01-01

    The Zr-based alloys are used in the nuclear industry. Particularly these alloys are used for the nuclear fuel elements in PWR reactors and CANDU type reactors. For this last case, zirconium-niobium (Zr-Nb) alloys have a particular importance for its special features like: resistance to corrosion, appropriate mechanic features and a low capture effective cross section for thermal neutrons. In this work the first LIBS measurements on Zr-Nb samples are shown. The spectrums from the plasma emission for Zr-Nb alloys are studied and discussed. Particularly, the variation of intensities as a function of laser energy is presented. Finally, the ablation morphology and the depth of the crater ablation are studied

  15. Sensitivity, stability, and precision of quantitative Ns-LIBS-based fuel-air-ratio measurements for methane-air flames at 1-11 bar.

    Science.gov (United States)

    Hsu, Paul S; Gragston, Mark; Wu, Yue; Zhang, Zhili; Patnaik, Anil K; Kiefer, Johannes; Roy, Sukesh; Gord, James R

    2016-10-01

    Nanosecond laser-induced breakdown spectroscopy (ns-LIBS) is employed for quantitative local fuel-air (F/A) ratio (i.e., ratio of actual fuel-to-oxidizer mass over ratio of fuel-to-oxidizer mass at stoichiometry, measurements in well-characterized methane-air flames at pressures of 1-11 bar). We selected nitrogen and hydrogen atomic-emission lines at 568 nm and 656 nm, respectively, to establish a correlation between the line intensities and the F/A ratio. We have investigated the effects of laser-pulse energy, camera gate delay, and pressure on the sensitivity, stability, and precision of the quantitative ns-LIBS F/A ratio measurements. We determined the optimal laser energy and camera gate delay for each pressure condition and found that measurement stability and precision are degraded with an increase in pressure. We have identified primary limitations of the F/A ratio measurement employing ns-LIBS at elevated pressures as instabilities caused by the higher density laser-induced plasma and the presence of the higher level of soot. Potential improvements are suggested.

  16. Laser-Induced Breakdown Spectroscopy (LIBS for Monitoring the Formation of Hydroxyapatite Porous Layers

    Directory of Open Access Journals (Sweden)

    Daniel Sola

    2017-12-01

    Full Text Available Laser-induced breakdown spectroscopy (LIBS is applied to characterize the formation of porous hydroxyapatite layers on the surface of 0.8CaSiO3-0.2Ca3(PO42 biocompatible eutectic glass immersed in simulated body fluid (SBF. Compositional and structural characterization analyses were also conducted by field emission scanning electron microscopy (FESEM, energy dispersive X-ray spectroscopy (EDX, and micro-Raman spectroscopy.

  17. Laser-induced breakdown spectroscopy (LIBS) for detection of ammonium nitrate in soils

    Science.gov (United States)

    Díaz, Daniel; Hahn, David W.; Molina, Alejandro

    2009-05-01

    The extensive use of improvised explosive devices (IED) by irregular armed groups in Colombia has posed a threat, not only to the Colombian regular army but to the civilian population. It is expected that in future years, after an eventual cease fire, humanitarian missions for IED clearance will be fundamental to secure safe transit of people and goods, particularly in Colombian rural areas. The clandestine nature of IEDs preparation in Colombia yielded a rather diverse nature of these irregular weapons. Although, some have metal parts such as nails and shrapnel, others are metal-free devices in which detonation is obtained by chemical means. Despite this variability in IEDs design, one thing that is common in IEDs preparation is the use of significant amounts of ANFO (ammonium nitrate (AN), fuel oil (FO)) in their construction. The goal of this work was to identify AN and FO in soils using LIBS. Experiments showed the ability of LIBS to identify the presence of AN based on Hα (656.3 nm) and Hβ (486.1 nm) emission lines. It was not possible to identify FO mixed with soils in the spectral windows studied. FO caused a reduction on spark intensity on the samples. This would represent a challenge for identification of chemical compounds in wet soils. Potential interferences with fertilizers are discussed as well.

  18. Preliminary study on detection sediment contamination in soil affected by the Indian Ocean giant tsunami 2004 in Aceh, Indonesia using laser-induced breakdown spectroscopy (LIBS)

    Energy Technology Data Exchange (ETDEWEB)

    Idris, Nasrullah, E-mail: nasrullah.idris@unsyiah.ac.id [Department of Physics, Faculty of Mathematics and Natural Sciences, Syiah Kuala University, Jl. Syech Abdurrauf No. 3 Darussalam, 23111 Banda Aceh, Aceh (Indonesia); Ramli, Muliadi [Department of Chemistry, Faculty of Mathematics and Natural Sciences, Syiah Kuala University, Jl. Syech Abdurrauf No. 3 Darussalam, 23111 Banda Aceh, Aceh (Indonesia); Hedwig, Rinda; Lie, Zener Sukra [Department of Computer Engineering, Bina Nusantara University, 9 K. H. Syahdan, Jakarta 14810 (Indonesia); Kurniawan, Koo Hendrik [Research Center of Maju Makmur Mandiri Foundation, 40 Srengseng Raya, Kembangan, Jakarta Barat 11630, Jakarta (Indonesia)

    2016-03-11

    This work is intended to asses the capability of LIBS for the detection of the tsunami sediment contamination in soil. LIBS apparatus used in this work consist of a laser system and an optical multichannel analyzer (OMA) system. The soil sample was collected from in Banda Aceh City, Aceh, Indonesia, the most affected region by the giant Indian Ocean tsunami 2004. The laser beam was focused onto surface of the soil pellet using a focusing lens to produce luminous plasma. The experiment was conducted under air as surrounding gas at 1 atmosphere. The emission spectral lines from the plasma were detected by the OMA system. It was found that metal including heavy metals can surely be detected, thus implying the potent of LIBS technique as a fast screening tools of tsunami sediment contamination.

  19. Libérer le double, la beauté sera convulsive…

    OpenAIRE

    Beauvoir-Dominique, Rachel

    2008-01-01

    Rachel Beauvoir-Dominique, Libérer le double, la beauté sera convulsive... À propos d’une collection d’art vodou. — De 1980 à ce jour, grâce au dévouement de Madame Marianne Lehmann, une collection unique de trésors du répertoire plastique vodou et « Makaya » a été rassemblée. Dotée de plusieurs milliers d’objets de culte, cette impressionnante collection n’a pas encore été exposée publiquement de manière permanente ; elle a cependant déjà attiré l’attention de nombreuses institutions nationa...

  20. Minimizing core deposits radiation fields in PWRs by coordinated Li/B chemistry

    International Nuclear Information System (INIS)

    Roesmer, J.

    1983-01-01

    The effect of coolant chemistry on the buildup and composition of core deposits and on out-of-core radiation fields was investigated in the Beaver Valley and Trojan plants. Coordinated Li/B coolant chemistry led to an appreciable reduction of the surface concentration of core deposits, decreased greatly the formation of crud films on fresh fuel, and resulted in a reduction in the rate and level of radiation field buildup in the out-of-core regions of the primary circuits. (author)

  1. Laser-Induced Breakdown Spectroscopy (LIBS) for the Measurement of Spatial Structures and Fuel Distribution in Flames.

    Science.gov (United States)

    Kotzagianni, Maria; Kakkava, Eirini; Couris, Stelios

    2016-04-01

    Laser-induced breakdown spectroscopy (LIBS) is used for the mapping of local structures (i.e., reactants and products zones) and for the determination of fuel distribution by means of the local equivalence ratio ϕ in laminar, premixed air-hydrocarbon flames. The determination of laser threshold energy to induce breakdown in the different zones of flames is employed for the identification and demarcation of the local structures of a premixed laminar flame, while complementary results about fuel concentration were obtained from measurements of the cyanogen (CN) band Β(2)Σ(+)--Χ(2)Σ(+), (Δυ = 0) at 388.3 nm and the ratio of the atomic lines of hydrogen (Hα) and oxygen (O(I)), Hα/O. The combination of these LIBS-based methods provides a relatively simple to use, rapid, and accurate tool for online and in situ combustion diagnostics, providing valuable information about the fuel distribution and the spatial variations of the local structures of a flame. © The Author(s) 2016.

  2. Scintillation characteristics of LiB3O5 and β-BaB2O4 single crystals

    International Nuclear Information System (INIS)

    Nazarenko, B.P.; Pedash, V.Yu.; Shekhovtsov, A.N.; Tarasov, V.A.; Zelenskaya, O.V.

    2006-01-01

    LiB 3 O 5 and β-BaB 2 O 4 single crystals have been grown by the top seeded solution growth technique. The optical characteristics and scintillation parameters of the grown single crystals have been tested and discussed

  3. A kinetics study of acetic acid on cobalt leaching of spent LIBs: Shrinking Core Model

    Directory of Open Access Journals (Sweden)

    Setiawan Hendrik

    2018-01-01

    Full Text Available Lithium-ion batteries (LIBs are secondary rechargeable power sources which increasing production also leads to large amount of waste. In order to environmentally friendly reduce the waste, this work aimed to use acetic acid as a substitute leaching agent to leach Co metals which constitutes about 72.39% wt of the battery cathode. The leaching process was done in a three-necked-flask where calcined LIB cathode powder was mixed with acetic acid solution. The variables of the leaching process under investigation were solution pH, concentration of H2O2 in the solution, S/L ratio, temperature and reaction time. Experimental results showed that only temperature significantly influenced the leaching rate of Co. Since the process was exothermic, the maximum recovery decreased as temperature increased. Conventional shrinking core model that considers diffusion and irreversible surface reaction resistances was found not sufficient to predict the kinetics of the Co leaching with acetic acid. A more representative kinetics model that considers a reversible reaction of Co complex formation needs to be further developed.

  4. La libéralisation comme source du dérèglement des transports ...

    African Journals Online (AJOL)

    proposant un phasage chronologique relatif à son évolution, tout en mettant la lumière sur ses effets les plus manifestes à l'échelle nationale et surtout sur le plan urbain par rapport au périmètre de transport de la ville d'Annaba, ceci à travers ses différents volets organisationnels et fonctionnels. Mots clés: Libéralisation ...

  5. Laser-induced breakdown spectroscopy (LIBS) analysis of calcium ions dissolved in water using filter paper substrates: an ideal internal standard for precision improvement.

    Science.gov (United States)

    Choi, Daewoong; Gong, Yongdeuk; Nam, Sang-Ho; Han, Song-Hee; Yoo, Jonghyun; Lee, Yonghoon

    2014-01-01

    We report an approach for selecting an internal standard to improve the precision of laser-induced breakdown spectroscopy (LIBS) analysis for determining calcium (Ca) concentration in water. The dissolved Ca(2+) ions were pre-concentrated on filter paper by evaporating water. The filter paper was dried and analyzed using LIBS. By adding strontium chloride to sample solutions and using a Sr II line at 407.771 nm for the intensity normalization of Ca II lines at 393.366 or 396.847 nm, the analysis precision could be significantly improved. The Ca II and Sr II line intensities were mapped across the filter paper, and they showed a strong positive shot-to-shot correlation with the same spatial distribution on the filter paper surface. We applied this analysis approach for the measurement of Ca(2+) in tap, bottled, and ground water samples. The Ca(2+) concentrations determined using LIBS are in good agreement with those obtained from flame atomic absorption spectrometry. Finally, we suggest a homologous relation of the strongest emission lines of period 4 and 5 elements in groups IA and IIA based on their similar electronic structures. Our results indicate that the LIBS can be effectively applied for liquid analysis at the sub-parts per million level with high precision using a simple drying of liquid solutions on filter paper and the use of the correct internal standard elements with the similar valence electronic structure with respect to the analytes of interest.

  6. Relationship between LIBS Ablation and Pit Volume for Geologic Samples: Applications for in situ Absolute Geochronology

    Science.gov (United States)

    Devismes, D.; Cohen, Barbara A.

    2014-01-01

    In planetary sciences, in situ absolute geochronology is a scientific and engineering challenge. Currently, the age of the Martian surface can only be determined by crater density counting. However this method has significant uncertainties and needs to be calibrated with absolute ages. We are developing an instrument to acquire in situ absolute geochronology based on the K-Ar method. The protocol is based on the laser ablation of a rock by hundreds of laser pulses. Laser Induced Breakdown Spectroscopy (LIBS) gives the potassium content of the ablated material and a mass spectrometer (quadrupole or ion trap) measures the quantity of 40Ar released. In order to accurately measure the quantity of released 40Ar in cases where Ar is an atmospheric constituent (e.g., Mars), the sample is first put into a chamber under high vacuum. The 40Arquantity, the concentration of K and the estimation of the ablated mass are the parameters needed to give the age of the rocks. The main uncertainties with this method are directly linked to the measures of the mass (typically some µg) and of the concentration of K by LIBS (up to 10%). Because the ablated mass is small compared to the mass of the sample, and because material is redeposited onto the sample after ablation, it is not possible to directly measure the ablated mass. Our current protocol measures the ablated volume and estimates the sample density to calculate ablated mass. The precision and accuracy of this method may be improved by using knowledge of the sample's geologic properties to predict its response to laser ablation, i.e., understanding whether natural samples have a predictable relationship between laser energy deposited and resultant ablation volume. In contrast to most previous studies of laser ablation, theoretical equations are not highly applicable. The reasons are numerous, but the most important are: a) geologic rocks are complex, polymineralic materials; b) the conditions of ablation are unusual (for example

  7. A novel specimen-preparing method using epoxy resin as binding material for LIBS analysis of powder samples.

    Science.gov (United States)

    Shi, Linli; Lin, Qingyu; Duan, Yixiang

    2015-11-01

    In view of the inevitable preprocessing of powder samples for LIBS detection, epoxy resin glue was investigated for the first time as a binder of powder samples due to its superior property of improved performance in laser induced breakdown spectroscopy (LIBS) technique as a quantitative analytical tool. For comparative studies of the epoxy resin and traditional polyethylene (PE) pellets in soil, sample detection, the signal intensities of Fe (I) at 404.58 nm, Ca (I) at 443.57 nm, and Cr (I) at 453.52 nm, were studied and subsequently, the calibration curves for these elements were constructed using the standard samples with variable concentrations. The signal intensities of epoxy resin samples were, on average, about 2 times greater than those obtained with the traditional PE pellet samples. Meanwhile, the resin samples showed better R square values of 0.981, 0.985 and 0.979 for curves of Fe (I) 404.58 nm, Ca (I) 443.57 nm, and Cr (I) 453.52 nm, compared to the 0.974, 0.950 and 0.934, of the PE pellet samples. Furthermore, the former represented lower limits of detection (LOD) for Fe, Ca and Cr. These experimental results indicated that this proposed novel method based on epoxy resin can attach samples of properties of high homogeneity, cohesiveness, smoothness and hardness, which are conducive to system stability, testing accuracy and signal enhancement. This method can make LIBS more practical in powder sample analysis. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Trollope, Liberalism and Scripture Libéralisme et Écritures dans l’œuvre d’Anthony Trollope

    Directory of Open Access Journals (Sweden)

    Hervé Picton

    2009-10-01

    Full Text Available Si au début de sa carrière littéraire Trollope était un partisan de la théologie anglo-catholique et antilibérale des Tractariens, il devint au fil des années sensible aux arguments des théologiens libéraux de la Broad Church. En effet, tous ses prêtres modèles après 1867 appartiennent à cette « Église large » (par opposition aux héros tractariens de ses premiers romans et il écrivit au cours des années 1865-1866 une série d’articles pour des revues libérales (PMG, Fornightly Review dans lesquelles il devait notamment soutenir l’évêque Colenso et son interprétation critique du Pentateuque. Trollope dénonce à présent le littéralisme biblique et soutient par ailleurs que le doute, aussi douloureux soit-il, est salutaire. Comment expliquer un tel revirement ? (Newman et les libéraux étaient après tout les pires ennemis. Les facteurs explicatifs sont nombreux et relèvent tant de la biographie que de l’évolution générale du climat intellectuel, avec en particulier la publication de The Origin of Species en 1859 et des Essays and Reviews en 1860. Anglican convaincu, Trollope ne devait toutefois jamais perdre la foi, contrairement à certains de ses amis libres penseurs tels que George Eliot ou G. H. Lewes.

  9. Improving Library Service Quality to Graduate Students: LibQual+[TM] Survey Results in a Practical Setting

    Science.gov (United States)

    Jankowska, Maria Anna; Hertel, Karen; Young, Nancy J.

    2006-01-01

    The LibQUAL+[TM] survey was conducted to determine user satisfaction and expectations concerning library service quality. The results of the "22 items and a box" constituted a rich source of information for the University of Idaho (UI) Library's strategic planning process. Focusing on graduate students, this study used three…

  10. NextLib : un sistema de software basado en ontologías para la consulta automática de OPACs desde sedes web especializadas

    OpenAIRE

    Felip Vidal, Lledó; Orduña-Malea, Enrique

    2008-01-01

    Las extensiones para navegadores web (Add-ons) están ampliando las funcionalidades de éstos. Entre ellas cabe destacar la reciente aparición de LibX, herramienta que permite la interacción entre el OPAC de una biblioteca y la Web. Se estudian las limitaciones de esta herramienta en cuanto a detección automática de datos y automatización de tareas para proponer un sistema (NextLib) que, mediante la combinación de diferentes aplicaciones, permita superarlas. Este sistema estaría for...

  11. Mapping of the spatial distribution of silver nanoparticles in root tissues of Vicia faba by laser-induced breakdown spectroscopy (LIBS).

    Science.gov (United States)

    Krajcarová, L; Novotný, K; Kummerová, M; Dubová, J; Gloser, V; Kaiser, J

    2017-10-01

    The manuscript presents a procedure for optimal sample preparation and the mapping of the spatial distribution of metal ions and nanoparticles in plant roots using laser-induced breakdown spectroscopy (LIBS) in a double-pulse configuration (DP LIBS) in orthogonal reheating mode. Two Nd:YAG lasers were used; the first one was an ablation laser (UP-266 MACRO, New Wave, USA) with a wavelength of 266nm, and the second one (Brilliant, Quantel, France), with a fundamental wavelength of 1064nm, was used to reheat the microplasma. Seedlings of Vicia faba were cultivated for 7 days in CuSO 4 or AgNO 3 solutions with a concentration of 10µmoll -1 or in a solution of silver nanoparticles (AgNPs) with a concentration of 10µmoll -1 of total Ag, and in distilled water as a control. The total contents of the examined metals in the roots after sample mineralization as well as changes in the concentrations of the metals in the cultivation solutions were monitored by ICP-OES. Root samples embedded in the TissueTek medium and cut into 40µm thick cross sections using the Cryo-Cut Microtome proved to be best suited for an accurate LIBS analysis with a 50µm spatial resolution. 2D raster maps of elemental distribution were created for the emission lines of Cu(I) at 324.754nm and Ag(I) at 328.068nm. The limits of detection of DP LIBS for the root cross sections were estimated to be 4pg for Cu, 18pg for Ag, and 3pg for AgNPs. The results of Ag spatial distribution mapping indicated that unlike Ag + ions, AgNPs do not penetrate into the inner tissues of Vicia faba roots but stay in their outermost layers. The content of Ag in roots cultivated in the AgNP solution was one order of magnitude lower compared to roots cultivated in the metal ion solutions. The significantly smaller concentration of Ag in root tissues cultivated in the AgNP solution also supports the conclusion that the absorption and uptake of AgNPs by roots of Vicia faba is very slow. LIBS mapping of root sections

  12. Snakes or Ladders? Evaluating a LibGuides pilot at University College Dublin Library

    OpenAIRE

    Dalton, Michelle; Pan, Rosalind

    2014-01-01

    Online subject guides are commonly used by libraries to provide information support to students. LibGuides (a cloud-based commercial product launched in 2007) represent one of the latest incarnations of the traditional subject guide or portal, and are widely used across American academic libraries. In Ireland however, library subject guides of entirely local design and hosted on a local web server still dominate. This paper outlines the project management process involved in implementing a Li...

  13. Characterizing the economic value of an epithermal Au-Ag ore with Laser Induced Breakdown Spectroscopy (LIBS)

    NARCIS (Netherlands)

    Dalm, M.; Buxton, M.W.N.

    2016-01-01

    LIBS was applied to 19 Au-Ag ore samples to investigate if this technique can be used to distinguish between economic and sub-economic ore either by direct detection of these elements or by using other elements as indicators. However, the Au and Ag grades of the samples are below the detection limit

  14. Taguchi Ukichi, un libéral opiniâtre de l’ère Meiji

    OpenAIRE

    Hurth, Pascal

    2014-01-01

    Journaliste, historien et homme politique, Taguchi Ukichi s’est fait le chantre du libéralisme à la fin du xixe siècle en défendant le libre-échange et en s’opposant aux propriétaires fonciers. Champion of Liberalism at the end of the 19th century, Taguchi Ukichi (journalist, historian and politician) was a staunch advocate of free trade, strongly opposed to landowners.

  15. Effect of sodium chloride concentration on elemental analysis of brines by laser-induced breakdown spectroscopy (LIBS).

    Science.gov (United States)

    Goueguel, Christian; Singh, Jagdish P; McIntyre, Dustin L; Jain, Jinesh; Karamalidis, Athanasios K

    2014-01-01

    Leakage of injected carbon dioxide (CO2) or resident fluids, such as brine, is a major concern associated with the injection of large volumes of CO2 into deep saline formations. Migration of brine could contaminate drinking water resources by increasing their salinity or endanger vegetation and animal life as well as human health. The main objective of this study was to investigate the effect of sodium chloride (NaCl) concentration on the detection of calcium and potassium in brine samples using laser-induced breakdown spectroscopy (LIBS). The ultimate goals were to determine the suitability of the LIBS technique for in situ measurements of metal ion concentrations in NaCl-rich solution and to develop a chemical sensor that can provide the early detection of brine intrusion into formations used for domestic or agricultural water production. Several brine samples of NaCl-CaCl2 and NaCl-KCl were prepared at NaCl concentrations between 0.0 and 3.0 M. The effect of NaCl concentration on the signal-to-background ratio (SBR) and signal-to-noise ratio (SNR) for calcium (422.67 nm) and potassium (769.49 nm) emission lines was evaluated. Results show that, for a delay time of 300 ns and a gate width of 3 μs, the presence of and changes in NaCl concentration significantly affect the SBR and SNR for both emission lines. An increase in NaCl concentration from 0.0 to 3.0 M produced an increase in the SNR, whereas the SBR dropped continuously. The detection limits obtained for both elements were in the milligrams per liter range, suggesting that a NaCl-rich solution does not severely limit the ability of LIBS to detect trace amount of metal ions.

  16. Heavy metal concentrations in soils as determined by laser-induced breakdown spectroscopy (LIBS), with special emphasis on chromium

    International Nuclear Information System (INIS)

    Senesi, G.S.; Dell'Aglio, M.; Gaudiuso, R.; De Giacomo, A.; Zaccone, C.; De Pascale, O.; Miano, T.M.; Capitelli, M.

    2009-01-01

    Soil is unanimously considered as one of the most important sink of heavy metals released by human activities. Heavy metal analysis of natural and polluted soils is generally conducted by the use of atomic absorption spectroscopy (AAS) or inductively coupled plasma optical emission spectroscopy (ICP-OES) on adequately obtained soil extracts. Although in recent years the emergent technique of laser-induced breakdown spectroscopy (LIBS) has been applied widely and with increasing success for the qualitative and quantitative analyses of a number of heavy metals in soil matrices with relevant simplification of the conventional methodologies, the technique still requires further confirmation before it can be applied fully successfully in soil analyses. The main objective of this work was to demonstrate that new developments in LIBS technique are able to provide reliable qualitative and quantitative analytical evaluation of several heavy metals in soils, with special focus on the element chromium (Cr), and with reference to the concentrations measured by conventional ICP spectroscopy. The preliminary qualitative LIBS analysis of five soil samples and one sewage sludge sample has allowed the detection of a number of elements including Al, Ca, Cr, Cu, Fe, Mg, Mn, Pb, Si, Ti, V and Zn. Of these, a quantitative analysis was also possible for the elements Cr, Cu, Pb, V and Zn based on the obtained linearity of the calibration curves constructed for each heavy metal, i.e., the proportionality between the intensity of the LIBS emission peaks and the concentration of each heavy metal in the sample measured by ICP. In particular, a triplet of emission lines for Cr could be used for its quantitative measurement. The consistency of experiments made on various samples was supported by the same characteristics of the laser-induced plasma (LIP), i.e., the typical linear distribution confirming the existence of local thermodynamic equilibrium (LTE) condition, and similar excitation

  17. Heavy metal concentrations in soils as determined by laser-induced breakdown spectroscopy (LIBS), with special emphasis on chromium.

    Science.gov (United States)

    Senesi, G S; Dell'Aglio, M; Gaudiuso, R; De Giacomo, A; Zaccone, C; De Pascale, O; Miano, T M; Capitelli, M

    2009-05-01

    Soil is unanimously considered as one of the most important sink of heavy metals released by human activities. Heavy metal analysis of natural and polluted soils is generally conducted by the use of atomic absorption spectroscopy (AAS) or inductively coupled plasma optical emission spectroscopy (ICP-OES) on adequately obtained soil extracts. Although in recent years the emergent technique of laser-induced breakdown spectroscopy (LIBS) has been applied widely and with increasing success for the qualitative and quantitative analyses of a number of heavy metals in soil matrices with relevant simplification of the conventional methodologies, the technique still requires further confirmation before it can be applied fully successfully in soil analyses. The main objective of this work was to demonstrate that new developments in LIBS technique are able to provide reliable qualitative and quantitative analytical evaluation of several heavy metals in soils, with special focus on the element chromium (Cr), and with reference to the concentrations measured by conventional ICP spectroscopy. The preliminary qualitative LIBS analysis of five soil samples and one sewage sludge sample has allowed the detection of a number of elements including Al, Ca, Cr, Cu, Fe, Mg, Mn, Pb, Si, Ti, V and Zn. Of these, a quantitative analysis was also possible for the elements Cr, Cu, Pb, V and Zn based on the obtained linearity of the calibration curves constructed for each heavy metal, i.e., the proportionality between the intensity of the LIBS emission peaks and the concentration of each heavy metal in the sample measured by ICP. In particular, a triplet of emission lines for Cr could be used for its quantitative measurement. The consistency of experiments made on various samples was supported by the same characteristics of the laser-induced plasma (LIP), i.e., the typical linear distribution confirming the existence of local thermodynamic equilibrium (LTE) condition, and similar excitation

  18. Creating a Current Awareness Service Using Yahoo! Pipes and LibGuides

    Directory of Open Access Journals (Sweden)

    Elizabeth Kiscaden

    2014-12-01

    Full Text Available Migration from print to electronic journals brought an end to traditional current awareness services, which primarily utilized print routing. The emergence of Real Simple Syndication, or RSS feeds, and email alerting systems provided users with alternative services. To assist users with adopting these technologies, a service utilizing aggregate feeds to the library’s electronic journal content was created and made available through LibGuides. Libraries can resurrect current awareness services using current technologies to increase awareness and usage of library-provided electronic journal content. The current awareness service presented is an example of how libraries can build simple current awareness services utilizing freely accessible technologies.

  19. Secondary plasma formation after single pulse laser ablation underwater and its advantages for laser induced breakdown spectroscopy (LIBS).

    Science.gov (United States)

    Gavrilović, M R; Cvejić, M; Lazic, V; Jovićević, S

    2016-06-07

    In this work we present studies of spatial and temporal plasma evolution after single pulse ablation of an aluminium target in water. The laser ablation was performed using 20 ns long pulses emitted at 1064 nm. The plasma characterization was performed by fast photography, the Schlieren technique, shadowgraphy and optical emission spectroscopy. The experimental results indicate the existence of two distinct plasma stages: the first stage has a duration of approximately 500 ns from the laser pulse, and is followed by a new plasma growth starting from the crater center. The secondary plasma slowly evolves inside the growing vapor bubble, and its optical emission lasts over several tens of microseconds. Later, the hot glowing particles, trapped inside the vapor cavity, were detected during the whole cycle of the bubble, where the first collapse occurs after 475 μs from the laser pulse. Differences in the plasma properties during the two evolution phases are discussed, with an accent on the optical emission since its detection is of primary importance for LIBS. Here we demonstrate that the LIBS signal quality in single pulse excitation underwater can be greatly enhanced by detecting only the secondary plasma emission, and also by applying long acquisition gates (in the order of 10-100 μs). The presented results are of great importance for LIBS measurements inside a liquid environment, since they prove that a good analytical signal can be obtained by using nanosecond pulses from a single commercial laser source and by employing cost effective, not gated detectors.

  20. libNeuroML and PyLEMS: using Python to combine procedural and declarative modeling approaches in computational neuroscience.

    Science.gov (United States)

    Vella, Michael; Cannon, Robert C; Crook, Sharon; Davison, Andrew P; Ganapathy, Gautham; Robinson, Hugh P C; Silver, R Angus; Gleeson, Padraig

    2014-01-01

    NeuroML is an XML-based model description language, which provides a powerful common data format for defining and exchanging models of neurons and neuronal networks. In the latest version of NeuroML, the structure and behavior of ion channel, synapse, cell, and network model descriptions are based on underlying definitions provided in LEMS, a domain-independent language for expressing hierarchical mathematical models of physical entities. While declarative approaches for describing models have led to greater exchange of model elements among software tools in computational neuroscience, a frequent criticism of XML-based languages is that they are difficult to work with directly. Here we describe two Application Programming Interfaces (APIs) written in Python (http://www.python.org), which simplify the process of developing and modifying models expressed in NeuroML and LEMS. The libNeuroML API provides a Python object model with a direct mapping to all NeuroML concepts defined by the NeuroML Schema, which facilitates reading and writing the XML equivalents. In addition, it offers a memory-efficient, array-based internal representation, which is useful for handling large-scale connectomics data. The libNeuroML API also includes support for performing common operations that are required when working with NeuroML documents. Access to the LEMS data model is provided by the PyLEMS API, which provides a Python implementation of the LEMS language, including the ability to simulate most models expressed in LEMS. Together, libNeuroML and PyLEMS provide a comprehensive solution for interacting with NeuroML models in a Python environment.

  1. libNeuroML and PyLEMS: using Python to combine imperative and declarative modelling approaches in computational neuroscience

    Directory of Open Access Journals (Sweden)

    Michael eVella

    2014-04-01

    Full Text Available NeuroML is an XML-based model description language, which provides a powerful common data format for defining and exchanging models of neurons and neuronal networks. In the latest version of NeuroML, the structure and behavior of ion channel, synapse, cell,and network model descriptions are based on underlying definitions provided in LEMS, a domain-independent language for expressing hierarchical mathematical models of physical entities. While declarative approaches for describing models have led to greater exchange of model elements among software tools in computational neuroscience, a frequent criticism of XML-based languages is that they are difficult to work with directly. Here we describe two APIs (Application Programming Interfaces written in Python (http://www.python.org, which simplify the process of developing and modifying models expressed in NeuroML and LEMS. The libNeuroML API provides a Python object model with a direct mapping to all NeuroML concepts defined by the NeuroML Schema, which facilitates reading and writing the XML equivalents. In addition, it offers a memory-efficient, array-based internal representation, which is useful for handling large-scale connectomics data. The libNeuroML API also includes support for performing common operations that are required when working with NeuroML documents. Access to the LEMS data model is provided by the PyLEMS API, which provides a Python implementation of the LEMS language, including the ability to simulate most models expressed in LEMS. Together, libNeuroML and PyLEMS provide a comprehensive solution for interacting with NeuroML models in a Python environment.

  2. Portable LIBS system for determining the composition of multilayer structures on objects of cultural value

    International Nuclear Information System (INIS)

    Moreira Osorio, Lesther; Ponce Cabrera, Luis V; Arronte Garcia, Miguel A; Flores Reyes, Teresa; Ravelo, Ivette

    2011-01-01

    This study presents the use of a portable Laser Induced Breakdown Spectroscopy (LIBS) prototype for determining the elemental composition of a metal jug. The system includes emission from a multiuse Q-switched Nd:YAG laser. By sampling at different points, the surface composition is determined. Furthermore, the presence of two layers of Pb and Cu and their thicknesses are determined through in-depth analysis.

  3. Identification of Four Wood Species by an Electronic Nose and by LIBS

    Directory of Open Access Journals (Sweden)

    Juliana R. Cordeiro

    2012-01-01

    Full Text Available This paper presents two complementary methods capable of identifying four wood species (Cedrela fissilis, Ocotea porosa, Hymenolobium petraeum, and Aspidosperma subincanum both by their volatile organic compounds and by the presence of 10 chemical elements: Al, B, Ca, Mg, Zn, Cu, Mn, Fe, Na, and Si. The volatile compounds were detected by an electronic nose formed by an array of three different conductive polymer gas sensors. The elemental determination was made by laser-induced breakdown spectrometry (LIBS. The emissions measured were treated by principal component analysis (PCA. Leave-one-out analysis showed a rate of hits of 100%.

  4. Arriba-lib: association of an evidence-based electronic library of decision aids with communication and decision-making in patients and primary care physicians.

    Science.gov (United States)

    Hirsch, Oliver; Keller, Heidemarie; Krones, Tanja; Donner-Banzhoff, Norbert

    2012-03-01

    In shared decision-making, patients are empowered to actively ask questions and participate in decisions about their healthcare based on their preferences and values. Decision aids should help patients make informed choices among diagnostic or treatment options by delivering evidence-based information on options and outcomes; however, they have rarely been field tested, especially in the primary care context. We therefore evaluated associations between the use of an interactive, transactional and evidence-based library of decision aids (arriba-lib) and communication and decision-making in patients and physicians in the primary care context. Our electronic library of decision aids ('arriba-lib') includes evidence-based modules for cardiovascular prevention, diabetes, coronary heart disease, atrial fibrillation and depression. Twenty-nine primary care physicians recruited 192 patients. We used questionnaires to ask patients and physicians about their experiences with and attitudes towards the programme. Patients were interviewed via telephone 2 months after the consultation. Data were analysed by general estimation equations, cross tab analyses and by using effect sizes. Only a minority (8.9%) of the consultations were felt to be too long because physicians said consultations were unacceptably extended by arriba-lib. We found a negative association between the detailedness of the discussion of the clinical problem's definition and the age of the patients. Physicians discuss therapeutic options in less detail with patients who have a formal education of less than 8 years. Patients who were counselled by a physician with no experience in using a decision aid more often reported that they do not remember being counselled with the help of a decision aid or do not wish to be counselled again with a decision aid. Arriba-lib has positive associations to the decision-making process in patients and physicians. It can also be used with older age groups and patients with less

  5. Adding Bite to the Bark: Using LibGuides2 Migration as Impetus to Introduce Strong Content Standards

    Science.gov (United States)

    Fritch, Melia; Pitts, Joelle E.

    2016-01-01

    The authors discuss the long-term accumulation of unstandardized and inaccessible content within the Libguides system and the decision-making process to create and implement a set of standards using the migration to the LibGuides2 platform as a vehicle for change. Included in the discussion are strategies for the creation of standards and…

  6. Detection and quantification of a toxic salt substitute (LiCl) by using laser induced breakdown spectroscopy (LIBS).

    Science.gov (United States)

    Sezer, Banu; Velioglu, Hasan Murat; Bilge, Gonca; Berkkan, Aysel; Ozdinc, Nese; Tamer, Ugur; Boyaci, Ismail Hakkı

    2018-01-01

    The use of Li salts in foods has been prohibited due to their negative effects on central nervous system; however, they might still be used especially in meat products as Na substitutes. Lithium can be toxic and even lethal at higher concentrations and it is not approved in foods. The present study focuses on Li analysis in meatballs by using laser induced breakdown spectroscopy (LIBS). Meatball samples were analyzed using LIBS and flame atomic absorption spectroscopy. Calibration curves were obtained by utilizing Li emission lines at 610nm and 670nm for univariate calibration. The results showed that Li calibration curve at 670nm provided successful determination of Li with 0.965 of R 2 and 4.64ppm of limit of detection (LOD) value. While Li Calibration curve obtained using emission line at 610nm generated R 2 of 0.991 and LOD of 22.6ppm, calibration curve obtained at 670nm below 1300ppm generated R 2 of 0.965 and LOD of 4.64ppm. Copyright © 2017. Published by Elsevier Ltd.

  7. A Simple Laser Induced Breakdown Spectroscopy (LIBS) System for Use at Multiple Levels in the Undergraduate Chemistry Curriculum

    Science.gov (United States)

    Randall, David W.; Hayes, Ryan T.; Wong, Peter A.

    2013-01-01

    A LIBS (laser induced breakdown spectroscopy) spectrometer constructed by the instructor is reported for use in undergraduate analytical chemistry experiments. The modular spectrometer described here is based on commonly available components including a commercial Nd:YAG laser and a compact UV-vis spectrometer. The modular approach provides a…

  8. Double Pulse LIBS of Titanium-Based PVD-Coatings with Submicron Resolution

    Directory of Open Access Journals (Sweden)

    K. Ermalitskaia

    2016-01-01

    Full Text Available The possibility for double pulse LIBS in the process of a direct layer-by-layer analysis of the titanium-based PVD-coatings on polished flat blank samples of steel and silicon and also of the TiAlN/TiN-coating on a milling cutter is considered. A method is proposed to control thickness of the radiation evaporated layer by defocusing the laser beam with respect to the surface, making it possible to attain the depth resolution of 0.1 μm. The Ti and Ti-Zr-coatings produced using the ion-assisted condensation method and subjected to streams of the nitrogen plasma in a magnetic-plasma compressor are studied.

  9. Feasibility of atomic and molecular laser induced breakdown spectroscopy (LIBS) to in-situ determination of chlorine in concrete : final report.

    Science.gov (United States)

    2016-10-01

    Laser-induced breakdown spectroscopy (LIBS) has been studied as a fast method of detecting chlorine in concrete samples. Both single pulse (SP) and double pulse (DP) experiments have been tested. Several combinations of lasers (Neodymium-Yttrium Alum...

  10. Less is more: Avoiding the LIBS dimensionality curse through judicious feature selection for explosive detection

    Science.gov (United States)

    Kumar Myakalwar, Ashwin; Spegazzini, Nicolas; Zhang, Chi; Kumar Anubham, Siva; Dasari, Ramachandra R.; Barman, Ishan; Kumar Gundawar, Manoj

    2015-01-01

    Despite its intrinsic advantages, translation of laser induced breakdown spectroscopy for material identification has been often impeded by the lack of robustness of developed classification models, often due to the presence of spurious correlations. While a number of classifiers exhibiting high discriminatory power have been reported, efforts in establishing the subset of relevant spectral features that enable a fundamental interpretation of the segmentation capability and avoid the ‘curse of dimensionality’ have been lacking. Using LIBS data acquired from a set of secondary explosives, we investigate judicious feature selection approaches and architect two different chemometrics classifiers –based on feature selection through prerequisite knowledge of the sample composition and genetic algorithm, respectively. While the full spectral input results in classification rate of ca.92%, selection of only carbon to hydrogen spectral window results in near identical performance. Importantly, the genetic algorithm-derived classifier shows a statistically significant improvement to ca. 94% accuracy for prospective classification, even though the number of features used is an order of magnitude smaller. Our findings demonstrate the impact of rigorous feature selection in LIBS and also hint at the feasibility of using a discrete filter based detector thereby enabling a cheaper and compact system more amenable to field operations. PMID:26286630

  11. Design and Construction of a pulsed Nd:YAG laser for LIBS applications

    Science.gov (United States)

    Garcia-Villarreal, A.; Sobral, H.

    2015-01-01

    A multi-pulse Nd:YAG laser was designed and built, that can be used as an excitation source for Laser Induced Breakdown Spectroscopy (LIBS) experiments. A trigger and a power supply for the flash lamp has been successfully developed. A cooling system that uses a distilled water flow for the active medium was implemented. The laser has an output energy of 306 ± 7 mJ for 1 Hz repetition rate and its temporal profile is multi-pulse with 1 ps of average separation between them. To validate the system, the output was used as an ablation source of an aluminum target and the emission was investigated by spectroscopy analysis.

  12. Evaluation of elemental profiling methods, including laser-induced breakdown spectroscopy (LIBS), for the differentiation of Cannabis plant material grown in different nutrient solutions.

    Science.gov (United States)

    El-Deftar, Moteaa M; Robertson, James; Foster, Simon; Lennard, Chris

    2015-06-01

    Laser-induced breakdown spectroscopy (LIBS) is an emerging atomic emission based solid sampling technique that has many potential forensic applications. In this study, the analytical performance of LIBS, as well as that of inductively coupled plasma mass spectrometry (ICP-MS), laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and X-ray microfluorescence (μXRF), was evaluated for the ability to conduct elemental analyses on Cannabis plant material, with a specific investigation of the possible links between hydroponic nutrients and elemental profiles from associated plant material. No such study has been previously published in the literature. Good correlation among the four techniques was observed when the concentrations or peak areas of the elements of interest were monitored. For Cannabis samples collected at the same growth time, the elemental profiles could be related to the use of particular commercial nutrients. In addition, the study demonstrated that ICP-MS, LA-ICP-MS and LIBS are suitable techniques for the comparison of Cannabis samples from different sources, with high discriminating powers being achieved. On the other hand, μXRF method was not suitable for the discrimination of Cannabis samples originating from different growth nutrients. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  13. Évaluation de la qualité de la connaissance dans une perspective délibérative

    NARCIS (Netherlands)

    van der Sluijs, J.P.; Douguet, J.M.; O'Connor, M.; Ravetz, J.

    2008-01-01

    sh Cet article propose une vision des démarches d’évaluation de l’adéquation de la connaissance scientifique dans des situations d’incertitude forte et irréductible en recourant à des processus délibératifs élargis. Dans l’optique de la Science Post-Normale, la démarche s’appuie, d’un point de vue

  14. Exploration of Mars with the ChemCam LIBS Instrument and the Curiosity Rover

    Science.gov (United States)

    Newsom, Horton E.

    2016-01-01

    The Mars Science Laboratory (MSL) Curiosity rover landed on Mars in August 2012, and has been exploring the planet ever since. Dr. Horton E. Newsom will discuss the MSL's design and main goal, which is to characterize past environments that may have been conducive to the evolution and sustainability of life. He will also discuss Curiosity's science payload, and remote sensing, analytical capabilities, and direct discoveries of the Chemistry & Camera (ChemCam) instrument, which is the first Laser Induced Breakdown Spectrometer (LIBS) to operate on another planetary surface and determine the chemistry of the rocks and soils.

  15. [Analysis of Cr in soil by LIBS based on conical spatial confinement of plasma].

    Science.gov (United States)

    Lin, Yong-Zeng; Yao, Ming-Yin; Chen, Tian-Bing; Li, Wen-Bing; Zheng, Mei-Lan; Xu, Xue-Hong; Tu, Jian-Ping; Liu, Mu-Hua

    2013-11-01

    The present study is to improve the sensitivity of detection and reduce the limit of detection in detecting heavy metal of soil by laser induced breakdown spectroscopy (LIBS). The Cr element of national standard soil was regarded as the research object. In the experiment, a conical cavity with small diameter end of 20 mm and large diameter end of 45 mm respectively was installed below the focusing lens near the experiment sample to mainly confine the signal transmitted by plasma and to some extent to confine the plasma itself in the LIBS setup. In detecting Cr I 425.44 nm, the beast delay time gained from experiment is 1.3 micros, and the relative standard deviation is below 10%. Compared with the setup of non-spatial confinement, the spectral intensity of Cr in the soil sample was enhanced more than 7%. Calibration curve was established in the Cr concentration range from 60 to 400 microg x g(-1). Under the condition of spatial confinement, the liner regression coefficient and the limit of detection were 0.997 71 and 18.85 microg x g(-1) respectively, however, the regression coefficient and the limit of detection were 0.991 22 and 36.99 microg x g(-1) without spatial confinement. So, this shows that conical spatial confinement can/improve the sensitivity of detection and enhance the spectral intensity. And it is a good auxiliary function in detecting Cr in the soil by laser induced breakdown spectroscopy.

  16. Quantum mechanical design and structure of the Li@B10H14 basket with a remarkably enhanced electro-optical response.

    Science.gov (United States)

    Muhammad, Shabbir; Xu, Hongliang; Liao, Yi; Kan, Yuhe; Su, Zhongmin

    2009-08-26

    An innovative type of lithium decahydroborate (Li@B(10)H(14)) complex with a basketlike complexant of decaborane (B(10)H(14)) has been designed using quantum mechanical methods. As Li atom binds in a handle fashion to terminal electrophilic boron atoms of the decaborane basket, its NBO charge q (Li) is found to be 0.876, close to +1. This shows that the Li atom has been ionized to form a cation and an anion at the open end of B(10)H(14). The most fascinating feature of this Li doping is its loosely bound valence electron, which has been pulled into the cavity of the B(10)H(14) basket and become diffuse by the electron-deficient morphological features of the open end of the B(10)H(14) basket. Strikingly, the first hyperpolarizability (beta(0)) of Li@B(10)H(14) is about 340 times larger than that of B(10)H(14), computed to be 23,075 au (199 x 10(-30) esu) and 68 au, respectively. Besides this, the intercalation of the Li atom to the B(10)H(14) basket brings some distinctive changes in its Raman, (11)B NMR, and UV-vis spectra along with its other electronic properties that might be used by the experimentalists to identify this novel kind of Li@B(10)H(14) complex with a large electro-optical response. This study may evoke the possibility to explore a new thriving area, i.e., alkali metal-boranes for NLO application.

  17. IDENTIFICACIÓN DE POLÍMEROS MEDIANTE ESPECTROSCOPIA DE EMISIÓN DE PLASMAS PRODUCIDOS POR LÁSER (LIBS

    Directory of Open Access Journals (Sweden)

    DANIEL DÍAZ

    2009-01-01

    Full Text Available Se espera que en Colombia en los próximos años se realicen misiones humanitarias para la remoción de Artefactos Explosivos Improvisados (AEI para asegurar el tránsito de personas y bienes, particularmente en zonas rurales. Entre las tecnologías que apoyan las labores de desminado humanitario, la espectroscopia de emisión de plasmas producidos por láser (LIBS tiene la capacidad de identificar explosivos y las cubiertas utilizadas en la fabricación de AEIs. En este trabajo la técnica LIBS se usó para identificar y caracterizar a nivel de laboratorio cinco polímeros que pueden ser usados en la fabricación de AEIs: polivinil cloruro, polietileno de alta densidad, polietileno tereftalato, poliestireno y polipropileno. Se utilizó el coeficiente de correlación lineal para la identificación de los polímeros. Se lograron identificar satisfactoriamente todos los polímeros al compararlos con librerías de distintas sustancias utilizando el promedio de cinco espectros en la ventana de análisis centrada en 255 nm.

  18. Accurate quantitative CF-LIBS analysis of both major and minor elements in alloys via iterative correction of plasma temperature and spectral intensity

    Science.gov (United States)

    Shuxia, ZHAO; Lei, ZHANG; Jiajia, HOU; Yang, ZHAO; Wangbao, YIN; Weiguang, MA; Lei, DONG; Liantuan, XIAO; Suotang, JIA

    2018-03-01

    The chemical composition of alloys directly determines their mechanical behaviors and application fields. Accurate and rapid analysis of both major and minor elements in alloys plays a key role in metallurgy quality control and material classification processes. A quantitative calibration-free laser-induced breakdown spectroscopy (CF-LIBS) analysis method, which carries out combined correction of plasma temperature and spectral intensity by using a second-order iterative algorithm and two boundary standard samples, is proposed to realize accurate composition measurements. Experimental results show that, compared to conventional CF-LIBS analysis, the relative errors for major elements Cu and Zn and minor element Pb in the copper-lead alloys has been reduced from 12%, 26% and 32% to 1.8%, 2.7% and 13.4%, respectively. The measurement accuracy for all elements has been improved substantially.

  19. Design of the Modelica Library VehProLib with Non-ideal Gas Models in Engines

    OpenAIRE

    Andersson, Conny

    2015-01-01

    This thesis covers the reconstruction and the redesign of the modeling library VehProLib,which is constructed in the modeling language Modelica with help of the modeling toolWolfram SystemModeler. The design choices are discussed and implemented. This thesisalso includes the implementation of a turbocharger package and an initial study of the justificationof the ideal gas law in vehicle modeling. The study is made with help of Van derWaals equation of states as a reference of non-ideal gas mo...

  20. Software support for SBGN maps: SBGN-ML and LibSBGN.

    Science.gov (United States)

    van Iersel, Martijn P; Villéger, Alice C; Czauderna, Tobias; Boyd, Sarah E; Bergmann, Frank T; Luna, Augustin; Demir, Emek; Sorokin, Anatoly; Dogrusoz, Ugur; Matsuoka, Yukiko; Funahashi, Akira; Aladjem, Mirit I; Mi, Huaiyu; Moodie, Stuart L; Kitano, Hiroaki; Le Novère, Nicolas; Schreiber, Falk

    2012-08-01

    LibSBGN is a software library for reading, writing and manipulating Systems Biology Graphical Notation (SBGN) maps stored using the recently developed SBGN-ML file format. The library (available in C++ and Java) makes it easy for developers to add SBGN support to their tools, whereas the file format facilitates the exchange of maps between compatible software applications. The library also supports validation of maps, which simplifies the task of ensuring compliance with the detailed SBGN specifications. With this effort we hope to increase the adoption of SBGN in bioinformatics tools, ultimately enabling more researchers to visualize biological knowledge in a precise and unambiguous manner. Milestone 2 was released in December 2011. Source code, example files and binaries are freely available under the terms of either the LGPL v2.1+ or Apache v2.0 open source licenses from http://libsbgn.sourceforge.net. sbgn-libsbgn@lists.sourceforge.net.

  1. Recovery Of Electrodic Powder From Spent Lithium Ion Batteries (LIBs

    Directory of Open Access Journals (Sweden)

    Shin S.M.

    2015-06-01

    Full Text Available This study was focused on recycling process newly proposed to recover electrodic powder enriched in cobalt (Co and lithium (Li from spent lithium ion battery. In addition, this new process was designed to prevent explosion of batteries during thermal treatment under inert atmosphere. Spent lithium ion batteries (LIBs were heated over the range of 300°C to 600°C for 2 hours and each component was completely separated inside reactor after experiment. Electrodic powder was successfully recovered from bulk components containing several pieces of metals through sieving operation. The electrodic powder obtained was examined by X-ray diffraction (XRD, energy dispersive X-ray spectroscopy (EDS, and atomic absorption spectroscopy (AA and furthermore image of the powder was taken by scanning electron microscopy (SEM. It was finally found that cobalt and lithium were mainly recovered to about 49 wt.% and 4 wt.% in electrodic powder, respectively.

  2. In situ NIR reflectance and LIBS measurements in lava tubes in preparation for future Mars missions

    Science.gov (United States)

    Leveille, R.; Sobron, P.

    2017-12-01

    The ATiLT (Astrobiology Training in Lava Tubes) program addresses Mars astrobiology exploration objectives by performing field work and instrumental analyses in lava tubes as high fidelity analog environments to putative lava tubes on Mars. The main field location for ATiLT is the Lava Beds National Monument (LABE) in Northern California. LABE is situated on the lower north flank of the Medicine Lake Volcano of the Cascade arc. This location features hundreds of caves, most of which are relatively shallow, typically well above the water table, reaching 20-45m below land surface at their maximum depth. Some LABE caves feature `cold sinks' where cold air sinks and becomes trapped in deeper cave passages, thus allowing perennial ice to accumulate despite above freezing surface temperatures. Several lava tube caves in LABE also contain seasonal or perennial ice accumulations, which makes them excellent analogs to Mars lava tubes where the presence of ice has been predicted. While lava tubes are very attractive systems to test hypotheses related to habitability and the possibility for life on Mars, at present there are no comprehensive in-situ instrument-driven characterizations of the mineralogy and geochemistry of lava tubes. ATiLT fills this gap by providing detailed, in-situ investigations with scientific instruments relevant to Mars exploration. Our aim is to help constrain future exploration targets on Mars and define future mission operations and requirements. For this purpose, in May 2017 we carried out a field campaign in several lava tubes at LABE. We deployed two miniature spectroscopic sensors suitable for dark, humid, cave conditions: NIR reflectance (1-5 μm) and LIBS (300-900 nm). The advantages of combining NIR reflectance and LIBS are evident: LIBS can reveal the relative concentration of major (and often trace) elements present in a bulk sample, whereas NIR reflectance yields information on the individual mineral species and their chemical and

  3. libLocation: acceso a dispositivos de localización para gvSIG Desktop y Mobile

    OpenAIRE

    Jordán Aldasorro, Juan G.; Planells Jiménez, Manuel

    2009-01-01

    Inicialmente integrada en el piloto de gvSIG Mobile, la librería libLocation tiene como objetivo dotar a los proyectos gvSIG Desktop y gvSIG Mobile un acceso transparente a fuentes de localización. La librería se fundamenta en las especificaciones JSR-179 -API de localización para J2ME- y JSR-293 -API de localización para J2ME v2.0-, proporcionando una interfaz uniforme a diferentes fuentes de localización, mediante funciones de alto nivel. Asimismo, se extiende la funcionalida...

  4. Detection of salts in soil using transversely excited atmospheric (TEA) carbon dioxide (CO2) laser-induced breakdown spectroscopy (LIBS) by the aid of a metal mesh

    Science.gov (United States)

    Idris, N.; Ramli, M.; Khumaeni, A.; Kurihara, K.

    2018-04-01

    In this work, a nickel metal mesh was used to allow a direct detection of salt in soil sample by LIBS utilizing unique characteristics of a TEA CO2. The metal mesh is placed in the front of the soil sample to prevent the soil sample from blowing off upon focusing the high pulsed laser beam irradiation. LIBS apparatus used in this work is a TEA CO2 laser operated at wavelength of 10.6 μm with pulse energy and duration of 3J and 200 ns, respectively. The laser beam was focused using a ZnSe lens (f = 200 mm) onto soil sample after passing through the metal mesh. The emission spectrum from the induced plasma was detected using an optical multichannel analyzer (OMA) system consisting of a 0.32-m-focal length spectrograph with a grating of 1200 graves/mm and a 1024-channel photodiode detector array with a micro-channel plate intensifier. The soil sample used is a standard soil and ordinary soil containing several salts such as Ca, Mg at high concentration. The LIBS experiment was carried out at high pressure surrounding gas of 1 atmosphere. It was observed that by the aid of the metal mesh, strong breakdown gas plasma can be produced just after TEA CO2 laser irradiation on soil sample without significant sample blowing off. It was found that emission lines from salts, Ca (Ca II 393. 3 nm, Ca II 396.3 nm, Ca I 422.5 nm), and also other salts including Mg and Na can clearly be detected with strong emission intensity and narrow spectral width. This result implies that a TEA CO2 LIBS assisted by the metal mesh (metal mesh method) can be used for direct analysis several salts such as Ca, Mg, and Na in soil sample.

  5. Direct spectral analysis of tea samples using 266 nm UV pulsed laser-induced breakdown spectroscopy and cross validation of LIBS results with ICP-MS.

    Science.gov (United States)

    Gondal, M A; Habibullah, Y B; Baig, Umair; Oloore, L E

    2016-05-15

    Tea is one of the most common and popular beverages spanning vast array of cultures all over the world. The main nutritional benefits of drinking tea are its anti-oxidant properties, presumed protection against certain cancers, inhibition of inflammation and possible protective effects against diabetes. Laser induced breakdown spectrometer (LIBS) was assembled as a powerful tool for qualitative and quantitative analysis of various brands of tea samples using 266 nm pulsed UV laser. LIBS spectra for six brands of tea samples in the wavelength range of 200-900 nm was recorded and all elements present in our tea samples were identified. The major toxic elements detected in several brands of tea samples were bromine, chromium and minerals like iron, calcium, potassium and silicon. The spectral assignment was conducted prior to the determination of concentration of each element. For quantitative analysis, calibration curves were drawn for each element using standard samples prepared in known concentration in the tea matrix. The plasma parameters (electron temperature and electron density) were also determined prior to the tea samples spectroscopic analysis. The concentration of iron, chromium, potassium, bromine, copper, silicon and calcium detected in all tea samples was between 378-656, 96-124, 1421-6785, 99-1476, 17-36, 2-11 and 92-130 mg L(-1) respectively. The limits of detection estimated for Fe, Cr, K, Br, Cu, Si, Ca in tea samples were 22, 12, 14, 11, 6, 1 and 12 mg L(-1) respectively. To further confirm the accuracy of our LIBS results, we determined the concentration of each element present in tea samples by using standard analytical technique like ICP-MS. The concentrations detected with our LIBS system are in excellent agreement with ICP-MS results. The system assembled for spectral analysis in this work could be highly applicable for testing the quality and purity of food and also pharmaceuticals products. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Investigation of the differentiation of ex vivo nerve and fat tissues using laser-induced breakdown spectroscopy (LIBS): Prospects for tissue-specific laser surgery.

    Science.gov (United States)

    Mehari, Fanuel; Rohde, Maximillian; Kanawade, Rajesh; Knipfer, Christian; Adler, Werner; Klämpfl, Florian; Stelzle, Florian; Schmidt, Michael

    2016-10-01

    In the present study, the elemental compositions of fat and nerve tissue during their plasma mediated laser ablation are studied in the context of tissue differentiation for laser surgery applications by using Laser-Induced Breakdown Spectroscopy (LIBS). Tissue samples of porcine fat and nerve were prepared as ex vivo experimental objects. Plasma mediated laser ablation is performed using an Nd : YAG laser in open air and under normal stray light conditions. The performed measurements suggest that the two tissue types show a high similarity in terms of qualitative elemental composition while at the same time revealing a distinct difference in the concentration of the constituent elements. Different analysis approaches are evaluated and discussed to optimize the tissue-differentiation performance of the LIBS approach. Plasma mediated laser tissue ablation. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Field deployment test of laser-induced breakdown spectroscopy (LIBS) technology at the Yucca Mountain Exploratory Studies Facility, Test Alcove No. 1, March 2-9, 1994: Milestone Report LA4047

    International Nuclear Information System (INIS)

    Blacic, J.; Pettit, D.; Cremers, D.

    1996-01-01

    A field test in the Exploratory Studies Facility at Yucca Mountain, Nevada was performed to determine the feasibility of real-time elemental analysis of rock encountered in air core drilling using the technique of laser-induced breakdown spectroscopy (LIBS). Over the period March 2-9, 1994, hundreds of LIBS spectra were collected in real-time, reflecting the elemental composition of dust produced at the drill head of the second horizontal core hole in Test Alcove No. 1. The particle-laden, drill-coring effluent air stream served as the means to obtain a representative rock sample immediately surrounding the drill bit. LIBS spectra were taken with the spectral range centered at 250, 330, 410, and 500 nm so that representative, overlapping spectral coverage from 200 to 550 nm was obtained for the dust. Spectral lines for the major elements Si, Al, K, Na, and Fe and the minor elements Ca, Mg, Ti, and Mn were observed. Some simple engineering improvements to the cyclone separator were identified if this approach to dust analysis is pursued in the future

  8. Pour une anthropologie de la libération For an Anthropology of the Liberation

    Directory of Open Access Journals (Sweden)

    Michael Singleton

    2011-09-01

    Full Text Available Foncièrement constructiviste, l’Anthropologie elle-même (à supposer, dato non concesso, que le singulier substantiel soit de mise n’est pas moins le “fait” d’une culture à l’exclusion, en dernière analyse, de toute autre. Néanmoins, produit en surface, mais processus en profondeur, bien que née et grandie dans un certain Occident, rien ne l’empêche d’inventer une identité inédite. D’où l’émergence à l’Université Catholique de Louvain d’une Anthropologie Prospective dont l’intentionnalité identitaire, impliquée jusqu’à l’indignation, rend libératrice. La Culture l’abhorrant autant sinon plus que la Nature, le vide laissé par la théologie de la libération, morte avec Dieu lui-même, pourrait être rempli par son pendant anthropo-logique.Fundamentally constructivist, Anthropology itself (supposing, but “dato non concesso”, that such a substantial singularity exists is no less the “fact” of one culture to the exclusion, in the last analysis, of all others.  However, seemingly a product but basically a process, though born and bred in the West, there is nothing to prevent anthropology from reinventing its identity.  Hence the emergence in the Catholic University of Louvain, of a Prospective Anthropology whose committed and at times indignant intentionality makes for freedom. Culture abhorring it as much if not more than Nature, the vacuum left by the demise of liberation theology subsequent to the Death of God himself, could be filled by an anthropo-logical equivalent.

  9. Exploring the Relationship between Patron Type, Carnegie Classification, and Satisfaction with Library Services: An Analysis of LibQUAL+® Results

    Science.gov (United States)

    Guder, Christopher S.

    2012-01-01

    The purpose of this study was to explore how faculty and students responded to the Information Control section of the LibQUAL+® survey at two libraries with different Carnegie Classifications. As one of the institutions being studied was considering a shift from a research institution to one more focused on teaching and learning, this study used…

  10. Identification of metal elements by time-resolved LIBS technique in sediments lake the “Cisne”

    Science.gov (United States)

    Pacheco, P.; Arregui, E.; Álvarez, J.; Rangel, N.; Sarmiento, R.

    2017-01-01

    Laser induced breakdown spectroscopy (LIBS), is a kind of spectral method of atomic emission that uses pulses of radiation high energy laser as excitation source. One of the advantages of technical LIBS lies in the possibility of analyse the substances in any State of aggregation, already is solid, liquid or gaseous, even in colloids as aerosols, gels and others. Another advantage over other conventional techniques is the simultaneous analysis of elements present in a sample of multielement. This work is made in the use of this technique for the identification of metal pollutants in the Swan Lake sediment samples, collected by drilling cores. Plasmas were generated by focusing the radiation of Nd: YAG laser with an energy per pulse 13mJ and 4ns duration, wavelength of 532nm. The spectra of radiation from the plasmas of sediment were recorded with an Echelle spectrograph type coupled to an ICCD camera. The delay times were between 0.5μs and 7μs, while the gate width was of 2μs. To ensure the homogeneity of the plasmas, the sediment sample was placed in a positioning system of linear and rotary adjustment of smooth step synchronized with the trigger of the laser pulse. The registration of the spectra of the sediment to different times of delay, allowed to identify the lines prominent of the different elements present in the sample. The analysis of the Spectra allowed the identification of some elements in the sample as if, Ca, Na, Mg, and Al through the measurement of wavelengths of the prominent peaks.

  11. Identification of metal elements by time-resolved LIBS technique in sediments lake the “Cisne”

    International Nuclear Information System (INIS)

    Pacheco, P; Arregui, E; Álvarez, J; Rangel, N; Sarmiento, R

    2017-01-01

    Laser induced breakdown spectroscopy (LIBS), is a kind of spectral method of atomic emission that uses pulses of radiation high energy laser as excitation source. One of the advantages of technical LIBS lies in the possibility of analyse the substances in any State of aggregation, already is solid, liquid or gaseous, even in colloids as aerosols, gels and others. Another advantage over other conventional techniques is the simultaneous analysis of elements present in a sample of multielement. This work is made in the use of this technique for the identification of metal pollutants in the Swan Lake sediment samples, collected by drilling cores. Plasmas were generated by focusing the radiation of Nd: YAG laser with an energy per pulse 13mJ and 4ns duration, wavelength of 532nm. The spectra of radiation from the plasmas of sediment were recorded with an Echelle spectrograph type coupled to an ICCD camera. The delay times were between 0.5μs and 7μs, while the gate width was of 2μs. To ensure the homogeneity of the plasmas, the sediment sample was placed in a positioning system of linear and rotary adjustment of smooth step synchronized with the trigger of the laser pulse. The registration of the spectra of the sediment to different times of delay, allowed to identify the lines prominent of the different elements present in the sample. The analysis of the Spectra allowed the identification of some elements in the sample as if, Ca, Na, Mg, and Al through the measurement of wavelengths of the prominent peaks. (paper)

  12. LibCPIXE: A PIXE simulation open-source library for multilayered samples

    International Nuclear Information System (INIS)

    Pascual-Izarra, C.; Barradas, N.P.; Reis, M.A.

    2006-01-01

    Most particle induced X-ray emission (PIXE) data analysis codes are not focused on handling multilayered samples. We have developed an open-source library called 'LibCPIXE', for PIXE data analysis. It is written in standard C and implements functions for simulating X-ray yields of PIXE spectra taken from arbitrary samples, including multilayered targets. The library is designed to be fast, portable, modular and scalable, as well as to facilitate its incorporation into any existing program. In order to demonstrate the capabilities of the library, a program called CPIXE was developed and used to analyze various real samples involving both bulk and layered samples. Just as the library, the CPIXE source code is freely available under the General Public License. We demonstrate that it runs both under GNU/Linux systems as well as under MS Windows. There is in principle no limitation to port it to other platforms

  13. Acceptance of shared decision making with reference to an electronic library of decision aids (arriba-lib) and its association to decision making in patients: an evaluation study.

    Science.gov (United States)

    Hirsch, Oliver; Keller, Heidemarie; Krones, Tanja; Donner-Banzhoff, Norbert

    2011-07-07

    Decision aids based on the philosophy of shared decision making are designed to help patients make informed choices among diagnostic or treatment options by delivering evidence-based information on options and outcomes. A patient decision aid can be regarded as a complex intervention because it consists of several presumably relevant components. Decision aids have rarely been field tested to assess patients' and physicians' attitudes towards them. It is also unclear what effect decision aids have on the adherence to chosen options. The electronic library of decision aids (arriba-lib) to be used within the clinical encounter has a modular structure and contains evidence-based decision aids for the following topics: cardiovascular prevention, atrial fibrillation, coronary heart disease, oral antidiabetics, conventional and intensified insulin therapy, and unipolar depression. We conducted an evaluation study in which 29 primary care physicians included 192 patients. After the consultation, patients filled in questionnaires and were interviewed via telephone two months later. We used generalised estimation equations to measure associations within patient variables and traditional crosstab analyses. Patients were highly satisfied with arriba-lib and the process of shared decision making. Two-thirds of patients reached in the telephone interview wanted to be counselled again with arriba-lib. There was a high congruence between preferred and perceived decision making. Of those patients reached in the telephone interview, 80.7% said that they implemented the decision, independent of gender and education. Elderly patients were more likely to say that they implemented the decision. Shared decision making with our multi-modular electronic library of decision aids (arriba-lib) was accepted by a high number of patients. It has positive associations to general aspects of decision making in patients. It can be used for patient groups with a wide range of individual

  14. Detection of calculus by laser-induced breakdown spectroscopy (LIBS) using an ultra-short pulse laser system (USPL)

    Science.gov (United States)

    Schelle, F.; Brede, O.; Krueger, S.; Oehme, B.; Dehn, C.; Frentzen, M.; Braun, A.

    2011-03-01

    The aim of this study was to assess the detection of calculus by Laser Induced Breakdown Spectroscopy (LIBS). The study was performed with an Nd:YVO4 laser, emitting pulses with a duration of 8 ps at a wavelength of 1064 nm. A repetition rate of 500 kHz at an average power of 5 W was used. Employing a focusing lense, intensities of the order of 1011 W/cm2 were reached on the tooth surface. These high intensities led to the generation of a plasma. The light emitted by the plasma was collimated into a fibre and then analyzed by an echelle spectroscope in the wavelength region from 220 nm - 900 nm. A total number of 15 freshly extracted teeth was used for this study. For each tooth the spectra of calculus and cementum were assessed separately. Comprising all single measurements median values were calculated for the whole spectrum, leading to two specific spectra, one for calculus and one for cementum. For further statistical analysis 28 areas of interest were defined as wavelength regions, in which the signal strength differed regarding the material. In 7 areas the intensity of the calculus spectrum differed statistically significant from the intensity of the cementum spectrum (p calculus. Further studies are necessary to verify that LIBS is a minimally invasive method allowing a safe application in laser-guided dentistry.

  15. Laser-induced breakdown spectroscopy (LIBS) technique for the determination of the chemical composition of complex inorganic materials

    Science.gov (United States)

    Łazarek, Łukasz; Antończak, Arkadiusz J.; Wójcik, Michał R.; Kozioł, Paweł E.; Stepak, Bogusz; Abramski, Krzysztof M.

    2014-08-01

    Laser-induced breakdown spectroscopy (LIBS) is a fast, fully optical method, that needs little or no sample preparation. In this technique qualitative and quantitative analysis is based on comparison. The determination of composition is generally based on the construction of a calibration curve namely the LIBS signal versus the concentration of the analyte. Typically, to calibrate the system, certified reference materials with known elemental composition are used. Nevertheless, such samples due to differences in the overall composition with respect to the used complex inorganic materials can influence significantly on the accuracy. There are also some intermediate factors which can cause imprecision in measurements, such as optical absorption, surface structure, thermal conductivity etc. This paper presents the calibration procedure performed with especially prepared pellets from the tested materials, which composition was previously defined. We also proposed methods of post-processing which allowed for mitigation of the matrix effects and for a reliable and accurate analysis. This technique was implemented for determination of trace elements in industrial copper concentrates standardized by conventional atomic absorption spectroscopy with a flame atomizer. A series of copper flotation concentrate samples was analyzed for contents of three elements, that is silver, cobalt and vanadium. It has been shown that the described technique can be used to qualitative and quantitative analyses of complex inorganic materials, such as copper flotation concentrates.

  16. Measurement of Cerium and Gadolinium in Solid Lithium Chloride-Potassium Chloride Salt Using Laser-Induced Breakdown Spectroscopy (LIBS).

    Science.gov (United States)

    Williams, Ammon; Bryce, Keith; Phongikaroon, Supathorn

    2017-10-01

    Pyroprocessing of used nuclear fuel (UNF) has many advantages-including that it is proliferation resistant. However, as part of the process, special nuclear materials accumulate in the electrolyte salt and present material accountability and safeguards concerns. The main motivation of this work was to explore a laser-induced breakdown spectroscopy (LIBS) approach as an online monitoring technique to enhance the material accountability of special nuclear materials in pyroprocessing. In this work, a vacuum extraction method was used to draw the molten salt (CeCl 3 -GdCl 3 -LiCl-KCl) up into 4 mm diameter Pyrex tubes where it froze. The salt was then removed and the solid salt was measured using LIBS and inductively coupled plasma mass spectroscopy (ICP-MS). A total of 36 samples were made that varied the CeCl 3 and GdCl 3 (surrogates for uranium and plutonium, respectively) concentrations from 0.5 wt% to 5 wt%. From these samples, univariate calibration curves for Ce and Gd were generated using peak area and peak intensity methods. For Ce, the Ce 551.1 nm line using the peak area provided the best calibration curve with a limit of detection (LOD) of 0.099 wt% and a root mean squared error of cross-validation (RMSECV) of 0.197 wt%. For Gd, the best curve was generated using the peak intensities of the Gd 564.2 nm line resulting in a LOD of 0.027 wt% and a RMSECV of 0.295 wt%. The RMSECV for the univariate cases were determined using leave-one-out cross-validation. In addition to the univariate calibration curves, partial least squares (PLS) regression was done to develop a calibration model. The PLS models yielded similar results with RMSECV (determined using Venetian blind cross-validation with 17% left out per split) values of 0.30 wt% and 0.29 wt% for Ce and Gd, respectively. This work has shown that solid pyroprocessing salt can be qualitatively and quantitatively monitored using LIBS. This work has the potential of significantly enhancing

  17. Optimal conditions for taking spectra of coffee beans plasma spectroscopy induced by laser (LIBS)

    International Nuclear Information System (INIS)

    Diaz Guerrero, A. M.; Flores Reyes; Ponce Cabrera, L. V.

    2016-01-01

    Coffee beans, arabica and robusta, from Mexico (Chiapas and Veracruz), Colombia, Kenya and Sumatra were analyzed by Laser-induced breakdown spectroscopy (LIBS). The time delay and pulse energy were varied in order to find the optimal conditions for taking spectra in coffee beans; finding that the increased visibility of the peaks and the lowest electronic background is observed with 1 s and 450 mJ. Spectra were taken in different regions of grain area to confirm its homogeneous composition. It was found that the intensity of the signal Ca is much higher than that of K in African coffee, lower in the coffee of America, and much lower in the coffee from Asia. (Author)

  18. Creating Tomorrow's Technologists: Contrasting Information Technology Curriculum in North American Library and Information Science Graduate Programs against Code4lib Job Listings

    Science.gov (United States)

    Maceli, Monica

    2015-01-01

    This research study explores technology-related course offerings in ALA-accredited library and information science (LIS) graduate programs in North America. These data are juxtaposed against a text analysis of several thousand LIS-specific technology job listings from the Code4lib jobs website. Starting in 2003, as a popular library technology…

  19. What Technology Skills Do Developers Need? A Text Analysis of Job Listings in Library and Information Science (LIS from Jobs.code4lib.org

    Directory of Open Access Journals (Sweden)

    Monica Maceli

    2015-09-01

    Full Text Available Technology plays an indisputably vital role in library and information science (LIS work; this rapidly moving landscape can create challenges for practitioners and educators seeking to keep pace with such change.  In pursuit of building our understanding of currently sought technology competencies in developer-oriented positions within LIS, this paper reports the results of a text analysis of a large collection of job listings culled from the Code4lib jobs website.  Beginning over a decade ago as a popular mailing list covering the intersection of technology and library work, the Code4lib organization's current offerings include a website that collects and organizes LIS-related technology job listings.  The results of the text analysis of this dataset suggest the currently vital technology skills and concepts that existing and aspiring practitioners may target in their continuing education as developers.

  20. Recent advances in the use of laser-induced breakdown spectroscopy (LIBS) as a rapid point-of-care pathogen diagnostic

    Science.gov (United States)

    Rehse, Steven; Trojand, Daniel; Putnam, Russell; Gillies, Derek; Woodman, Ryan; Sheikh, Khadija; Daabous, Andrew

    2013-05-01

    There is a well-known and urgent need in the fields of medicine, environmental health and safety, food-processing, and defense/security to develop new 21st Century technologies for the rapid and sensitive identification of bacterial pathogens. In only the last five years, the use of a real-time elemental (atomic) analysis performed with laser-induced breakdown spectroscopy (LIBS) has made tremendous progress in becoming a viable technology for rapid bacterial pathogen detection and identification. In this talk we will show how this laser-based optical emission spectroscopic technique is able to sensitively assay the elemental composition of bacterial cells in situ. We will also present the latest achievements of our lab to fully develop LIBS-based bacterial sensing including simulation of a rapid urinary tract infection diagnosis and investigation of a variety of autonomous multivariate analysis algorithms. Lastly, we will show how this technology is now ready to be transitioned from the laboratory to field-portable and potentially man-portable instrumentation. The introduction of such a technology into popular use could very well transform the field of bacterial biosensing - a market valued at approximately 10 billion/year world-wide. Funding for this project was provided in part by a Natural Sciences and Engineering Research Council of Canada Discovery Grant.

  1. Quantitative Analysis of Heavy Metals in Water Based on LIBS with an Automatic Device for Sample Preparation

    International Nuclear Information System (INIS)

    Hu Li; Zhao Nanjing; Liu Wenqing; Meng Deshuo; Fang Li; Wang Yin; Yu Yang; Ma Mingjun

    2015-01-01

    Heavy metals in water can be deposited on graphite flakes, which can be used as an enrichment method for laser-induced breakdown spectroscopy (LIBS) and is studied in this paper. The graphite samples were prepared with an automatic device, which was composed of a loading and unloading module, a quantitatively adding solution module, a rapid heating and drying module and a precise rotating module. The experimental results showed that the sample preparation methods had no significant effect on sample distribution and the LIBS signal accumulated in 20 pulses was stable and repeatable. With an increasing amount of the sample solution on the graphite flake, the peak intensity at Cu I 324.75 nm accorded with the exponential function with a correlation coefficient of 0.9963 and the background intensity remained unchanged. The limit of detection (LOD) was calculated through linear fitting of the peak intensity versus the concentration. The LOD decreased rapidly with an increasing amount of sample solution until the amount exceeded 20 mL and the correlation coefficient of exponential function fitting was 0.991. The LOD of Pb, Ni, Cd, Cr and Zn after evaporating different amounts of sample solution on the graphite flakes was measured and the variation tendency of their LOD with sample solution amounts was similar to the tendency for Cu. The experimental data and conclusions could provide a reference for automatic sample preparation and heavy metal in situ detection. (paper)

  2. Investigation of the wavelength dependence of laser stratigraphy on Cu and Ni coatings using LIBS compared to a pure thermal ablation model

    Science.gov (United States)

    Paulis, Evgeniya; Pacher, Ulrich; Weimerskirch, Morris J. J.; Nagy, Tristan O.; Kautek, Wolfgang

    2017-12-01

    In this study, galvanic coatings of Cu and Ni, typically applied in industrial standard routines, were investigated. Ablation experiments were carried out using the first two harmonic wavelengths of a pulsed Nd:YAG laser and the resulting plasma spectra were analysed using a linear Pearson correlation method. For both wavelengths the absorption/ablation behaviour as well as laser-induced breakdown spectroscopy (LIBS) depth profiles were studied varying laser fluences between 4.3-17.2 J/cm^2 at 532 nm and 2.9-11.7 J/cm^2 at 1064 nm. The LIBS-stratigrams were compared with energy-dispersive X-ray spectroscopy of cross-sections. The ablation rates were calculated and compared to theoretical values originating from a thermal ablation model. Generally, higher ablation rates were obtained with 532 nm light for both materials. The light-plasma interaction is suggested as possible cause of the lower ablation rates in the infrared regime. Neither clear evidence of the pure thermal ablation, nor correlation with optical properties of investigated materials was obtained.

  3. Relationship Between LIBS Ablation and Pit Volume for Geologic Samples: Applications for the In Situ Absolute Geochronology

    Science.gov (United States)

    Devismes, Damien; Cohen, Barbara; Miller, J.-S.; Gillot, P.-Y.; Lefevre, J.-C.; Boukari, C.

    2014-01-01

    These first results demonstrate that LIBS spectra can be an interesting tool to estimate the ablated volume. When the ablated volume is bigger than 9.10(exp 6) cubic micrometers, this method has less than 10% of uncertainties. Far enough to be directly implemented in the KArLE experiment protocol. Nevertheless, depending on the samples and their mean grain size, the difficulty to have homogeneous spectra will increase with the ablated volume. Several K-Ar dating studies based on this approach will be implemented. After that, the results will be shown and discussed.

  4. Sausage instabilities stabilized by radial motion in Z-discharged plasma channel for beam propagation in LIB-fusion

    International Nuclear Information System (INIS)

    Murakami, Hiroyuki; Kawata, Shigeo; Niu, Keishiro.

    1983-01-01

    The stability of current-carrying plasma channels, which have been proposed for transporting intense ion beams from the diodes to the target in LIB-fusion devices, is discussed. The growth rate of the most dangerous surface mode, that is, the axisymmetric sausage instabilities, are examined for plasma channels with or without radial fluid motion. The growth rate of the channel with radial fluid motion is shown to be far smaller than that of the channel with no fluid motion. It is concluded that a stable plasma channel can be formed by radial fluid motion. (author)

  5. User library service expectations in health science vs. other settings: a LibQUAL+ Study.

    Science.gov (United States)

    Thompson, Bruce; Kyrillidou, Martha; Cook, Colleen

    2007-12-01

    To explore how the library service expectations and perceptions of users might differ across health-related libraries as against major research libraries not operating in a medical context; to determine whether users of medical libraries demand better library service quality, because the inability of users to access needed literature promptly may lead to a patient who cannot be properly diagnosed, or a diagnosis that cannot be properly treated. We compared LibQUAL+ total and subscale scores across three groups of US, Canadian and British libraries for this purpose. Anticipated differences in expectations for health as other library settings did not emerge. The expectations and perceptions are similar across different types of health science library settings, hospital and academic, and across other general research libraries.

  6. STUDI PERBANDINGAN ANALISIS UNSUR PLUMBUM (PB DARI HASIL ELEKTROLISIS ANTARA METODE LASER- INDUCED BREAKDOWN SPECTROSCOPY (LIBS DENGAN METODE KONVENSIONAL

    Directory of Open Access Journals (Sweden)

    H. S. Suyanto

    2014-07-01

    Full Text Available Penelitian ini bertujuan menganalisis unsur Pb hasil proses elektrolisis dengan metode alternatif laser-induced breakdown spectroscopy (LIBS dan metode konvensional. Elektrolisis menggunakan tembaga (Cu sebagai katoda dan karbon sebagai anoda. Unsur Pb yang terdeposisi pada katoda diirradiasi laser Nd-YAG (model CFR 200, 1064nm dan emisinya (Pb I 405.7 nm ditangkap spektrometer HR 2500++ yang kemudian ditampilkan dalam intensitas fungsi panjang gelombang. Hasil penelitian menunjukkan bahwa energi laser, arus listrik dan waktu deposisi proses elektrolisis yang optimum untuk karakterisasi unsur Pb masing - masing adalah 100 mJ, 5,28 mA dan 15 menit. Aplikasi metode ini untuk analisis kuantitatif larutan Pb dengan membuat kurva kalibrasi dari kosentrasi 300 ppm sampai kosentrasi terendah yaitu 0,5 ppm, serta diperoleh deteksi limit sebesar 0,44 ppm. Sebagai perbandingan metode deteksi dengan LIBS ini telah dilakukan analisis dengan metode konvensional dengan menentukan selisih massa katoda sebelum dan sesudah elektrolisis dan diperoleh hasil yang sebanding.ABSTRACTThe aim of this research was to compare between a method of laser-induced breakdown spectroscopy (LIBS and the conventional one to analyse of Plumbum (Pb element resulted from electrolysis process. Electrolysis used copper (Cu and carbon (C as cathode and anode respectively. Plumbum element which was deposited on cathode was irradiated by Nd-YAG laser (model CFR 200, 1064nm and its emission intensity of neutral Pb I 405.7 nm in the plasma was captured by HR 2500++ spectrometer and displayed in a form of intensity as a function of wavelength. The experiment result showed that the optimum condition parameters of electrolysis: laser energy, electric current and electrolysis time duration were 100 mJ, 5.28 mA and 15 minutes respectively. An application of these conditions was done to make calibration curve of Pb element in liquid sample from 300 ppm to 0.5 ppm and resulted a limit of

  7. Le délibéré aux assises, ultime point aveugle dans l’affaire d’Outreau The deliberation in the Cour d’assises, last blind spot in the Outreau case

    OpenAIRE

    Jean-Marie Fayol-Noireterre

    2009-01-01

    Cet article envisage les délibérés des cours d’assises, en premier ressort et en appel, de l’affaire d’Outreau, à partir des auditions de la commission d’enquête parlementaire, et à la lumière d’une expérience professionnelle de magistrat (17 années comme juge des enfants, 16 années comme président d'assises). Cette libre projection permet de parcourir, à partir des textes de loi, des pratiques de conduites de délibérés. Il s'agit aussi d'aborder les problèmes inhérents au traitement judiciai...

  8. Ultrafast Laser-Based Spectroscopy and Sensing: Applications in LIBS, CARS, and THz Spectroscopy

    Science.gov (United States)

    Leahy-Hoppa, Megan R.; Miragliotta, Joseph; Osiander, Robert; Burnett, Jennifer; Dikmelik, Yamac; McEnnis, Caroline; Spicer, James B.

    2010-01-01

    Ultrafast pulsed lasers find application in a range of spectroscopy and sensing techniques including laser induced breakdown spectroscopy (LIBS), coherent Raman spectroscopy, and terahertz (THz) spectroscopy. Whether based on absorption or emission processes, the characteristics of these techniques are heavily influenced by the use of ultrafast pulses in the signal generation process. Depending on the energy of the pulses used, the essential laser interaction process can primarily involve lattice vibrations, molecular rotations, or a combination of excited states produced by laser heating. While some of these techniques are currently confined to sensing at close ranges, others can be implemented for remote spectroscopic sensing owing principally to the laser pulse duration. We present a review of ultrafast laser-based spectroscopy techniques and discuss the use of these techniques to current and potential chemical and environmental sensing applications. PMID:22399883

  9. Ultrafast Laser-Based Spectroscopy and Sensing: Applications in LIBS, CARS, and THz Spectroscopy

    Directory of Open Access Journals (Sweden)

    Megan R. Leahy-Hoppa

    2010-04-01

    Full Text Available Ultrafast pulsed lasers find application in a range of spectroscopy and sensing techniques including laser induced breakdown spectroscopy (LIBS, coherent Raman spectroscopy, and terahertz (THz spectroscopy. Whether based on absorption or emission processes, the characteristics of these techniques are heavily influenced by the use of ultrafast pulses in the signal generation process. Depending on the energy of the pulses used, the essential laser interaction process can primarily involve lattice vibrations, molecular rotations, or a combination of excited states produced by laser heating. While some of these techniques are currently confined to sensing at close ranges, others can be implemented for remote spectroscopic sensing owing principally to the laser pulse duration. We present a review of ultrafast laser-based spectroscopy techniques and discuss the use of these techniques to current and potential chemical and environmental sensing applications.

  10. KITAB AL-SANĪ AL-MAṬĀLIB: INTERKONEKSI NAHWU DAN TASAWUF

    Directory of Open Access Journals (Sweden)

    Zakiyah Zakiyah

    2012-12-01

    Tulisan ini mereview buku yang berjudul al-Sanī al-Maṭālib yang ditulis oleh Kiai Nur Iman Mlangi Yogyakarta. Buku ini ditulis dalam bahasa Arab yang me­ngandung interkoneksi antara ilmu Nahwu (tata bahasa Arab dengan mis­tisis­me. Buku ini sangat menarik karena kenyataan bahwa kedua pengetahuan tersebut memiliki aturan sendiri-sendiri. Selain itu, sangat sedikit penulis yang menulis dengan gaya seperti itu. Salah satunya adalah Syaikh Abdul Qadir bin Ahmad al-Kuhany dengan karyanya yang berjudul Manniyat al-Fāqir al-Munjarid wa Sayrat al-Murīd al-Mutafarrid. Buku al-Saniy al-Muthalib diduga telah ditulis pada akhir abad ke-18 atau awal abad ke-19, menurut periode kehidupan Kiai Nur Iman yaitu sekitar pertengahan abad ke-18. Aturan Nahwu dalam buku ini dijelaskan secara teosofi yang dimulai dengan penjelasan mengenai tauhid (keesaan Tuhan sebagai kajian dasar bagi orang Islam, yang diikuti dengan makna dari masing-masing aturan bahasa Arab dalam aspek mistiknya.

  11. Application of a spectrum standardization method for carbon analysis in coal using laser-induced breakdown spectroscopy (LIBS).

    Science.gov (United States)

    Li, Xiongwei; Wang, Zhe; Fu, Yangting; Li, Zheng; Liu, Jianmin; Ni, Weidou

    2014-01-01

    Measurement of coal carbon content using laser-induced breakdown spectroscopy (LIBS) is limited by its low precision and accuracy. A modified spectrum standardization method was proposed to achieve both reproducible and accurate results for the quantitative analysis of carbon content in coal using LIBS. The proposed method used the molecular emissions of diatomic carbon (C2) and cyanide (CN) to compensate for the diminution of atomic carbon emissions in high volatile content coal samples caused by matrix effect. The compensated carbon line intensities were further converted into an assumed standard state with standard plasma temperature, electron number density, and total number density of carbon, under which the carbon line intensity is proportional to its concentration in the coal samples. To obtain better compensation for fluctuations of total carbon number density, the segmental spectral area was used and an iterative algorithm was applied that is different from our previous spectrum standardization calculations. The modified spectrum standardization model was applied to the measurement of carbon content in 24 bituminous coal samples. The results demonstrate that the proposed method has superior performance over the generally applied normalization methods. The average relative standard deviation was 3.21%, the coefficient of determination was 0.90, the root mean square error of prediction was 2.24%, and the average maximum relative error for the modified model was 12.18%, showing an overall improvement over the corresponding values for the normalization with segmental spectrum area, 6.00%, 0.75, 3.77%, and 15.40%, respectively.

  12. Isolation and characterization of two mitoviruses and a putative alphapartitivirus from Fusarium spp.

    Science.gov (United States)

    Osaki, Hideki; Sasaki, Atsuko; Nomiyama, Koji; Sekiguchi, Hiroyuki; Tomioka, Keisuke; Takehara, Toshiaki

    2015-06-01

    The filamentous fungus Fusarium spp. includes several important plant pathogens. We attempted to reveal presence of double-stranded (ds) RNAs in the genus. Thirty-seven Fusarium spp. at the MAFF collection were analyzed. In the strains of Fusarium coeruleum, Fusarium globosum and Fusarium solani f. sp. pisi, single dsRNA bands were detected. The strains of F. coeruleum and F. solani f. sp. pisi cause potato dry rot and mulberry twig blight, respectively. Sequence analyses revealed that dsRNAs in F. coeruleum and F. globosum consisted of 2423 and 2414 bp, respectively. Using the fungal mitochondrial translation table, the positive strands of these cDNAs were found to contain single open reading frames with the potential to encode a protein of putative 757 and 717 amino acids (molecular mass 88.5 and 84.0 kDa, respectively), similar to RNA-dependent RNA polymerases of members of the genus Mitovirus. These dsRNAs in F. coeruleum and F. globosum were assigned to the genus Mitovirus (family Narnaviridae), and these two mitoviruses were designated as Fusarium coeruleum mitovirus 1 and Fusarium globosum mitovirus 1. On the other hand, a positive strand of cDNA (1950 bp) from dsRNA in F. solani f. sp. pisi contained an ORF potentially encoding a putative RdRp of 608 amino acids (72.0 kDa). The putative RdRp was shown to be related to those of members of the genus of Alphapartitivirus (family Partitiviridae). We coined the name Fusarium solani partitivirus 2 for dsRNA in F. solani f. sp. pisi.

  13. Study and development of the laser induced breakdown spectroscopy (LIBS) for the realization of field measurements: application to analysis on-line of metals in liquids

    International Nuclear Information System (INIS)

    Rosado, J.C.D.

    2013-01-01

    Metal contamination of water is a major public health issue. Controls and treatments are more drastic and performed on them for human consumption. It is essential for this to possess reliable and sensitive analytical tools adapted to the existing regulations and flexible enough to use. The technique of 'Laser Induced Breakdown Spectroscopy' (LIBS), proven for the analysis of solids, including exo-terrestrial explorations, this very interesting advantages for liquids including, for example, are multi-character elementary and the possibility of in-situ measurements of water contamination by metals. A first part of this study thesis allowed to explore the potential (LIBS) for the analysis of dissolved metals or suspensions in water. Study has found an important effect related to the particle size in the analysis of suspensions. A second prong is to look at the effects of organic matrix represented by humic acid and those natural minerals represented by the bentonite and alumina particles. The matrix effect observed was corrected by normalization by internal standard. (author) [fr

  14. Estimation of Soil Nitrate (NO3) Level Using Laser-Induced Breakdown Spectroscopy (LIBS)

    Science.gov (United States)

    Angkat, A. R.; Seminar, K. B.; Rahmat, M.; Sutandi, A.

    2018-05-01

    Laser-Induced Breakdown Spectroscopy (LIBS) is a method for measuring level of nitrogen (N) in the soil in the form of N-nitrate (NO3) rapidly without going through the process of sieving and drying. The sample soil in the form of pellets subjected to laser pulses using a wavelength of 532 nm, pulse duration 5.5 ns, repetition rate of 10 Hz, and Q-switch delay of 150 μs. Emissions are captured by the spectrometer with the wavelength range of 190-1130 nm. Spectrum characterization was processed through the second derivative in order to obtain a wavelength identity that could be rapidly used to estimate the nitrate content of the soil with a determination coefficient of (R2) 0.9254 and a coefficient of variation (CV) of 8.41%. The results of this study are very potential to be applied for rapid measurement of soil nitrate.

  15. Elemental analysis of soils using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and laser-induced breakdown spectroscopy (LIBS) with multivariate discrimination: tape mounting as an alternative to pellets for small forensic transfer specimens.

    Science.gov (United States)

    Jantzi, Sarah C; Almirall, José R

    2014-01-01

    Elemental analysis of soil is a useful application of both laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and laser-induced breakdown spectroscopy (LIBS) in geological, agricultural, environmental, archeological, planetary, and forensic sciences. In forensic science, the question to be answered is often whether soil specimens found on objects (e.g., shoes, tires, or tools) originated from the crime scene or other location of interest. Elemental analysis of the soil from the object and the locations of interest results in a characteristic elemental profile of each specimen, consisting of the amount of each element present. Because multiple elements are measured, multivariate statistics can be used to compare the elemental profiles in order to determine whether the specimen from the object is similar to one of the locations of interest. Previous work involved milling and pressing 0.5 g of soil into pellets before analysis using LA-ICP-MS and LIBS. However, forensic examiners prefer techniques that require smaller samples, are less time consuming, and are less destructive, allowing for future analysis by other techniques. An alternative sample introduction method was developed to meet these needs while still providing quantitative results suitable for multivariate comparisons. The tape-mounting method involved deposition of a thin layer of soil onto double-sided adhesive tape. A comparison of tape-mounting and pellet method performance is reported for both LA-ICP-MS and LIBS. Calibration standards and reference materials, prepared using the tape method, were analyzed by LA-ICP-MS and LIBS. As with the pellet method, linear calibration curves were achieved with the tape method, as well as good precision and low bias. Soil specimens from Miami-Dade County were prepared by both the pellet and tape methods and analyzed by LA-ICP-MS and LIBS. Principal components analysis and linear discriminant analysis were applied to the multivariate data

  16. Preliminary panoramic study of river calm muscle using neodymium:yttrium-aluminum-garnet (Nd: YAG) laser-induced breakdown spectroscopy (LIBS)

    Science.gov (United States)

    Idris, N.; Lahna, K.; Usmawanda, T. N.; Herman; Ramli, M.; Hedwig, R.; Marpaung, A. M.; Kurniawan, K. H.

    2018-04-01

    A wide coverage spectral investigation on the muscle of river calm sample has been carried out using laser-induced breakdown spectroscopy for examining the overall profile of the emission spectra from the produced plasma. The basic apparatus of LIBS system used is a Nd-YAG laser and wide coverage optical multichannel analyzer (OMA) system. The river clam samples used is collected from Panga River in Aceh Jaya Regency, Aceh, Indonesia up streaming in a mountain of Gunong Ujeun, which is used as a location of the intensive traditional mining activity. Assuming that heavy metal accumulated in the clam muscle, LIBS experiments were carried out on the muscle of the calm. The sample used was fresh muscle sliced and attached to a copper plate. Plasma was generated by focusing the laser beam on the sample surface under air surrounding gas at 1 atmosphere. It is found that there are only major elements of host organic, namely C, H, O, N and the minor element of salts can be detected from fresh the clam sample when using a high pulse laser energy under air surrounding at high pressure of 1 atmosphere. There is no emission lines from any metal can be detected. Several experimental parameters were explored to study the panoramic dynamic of the emission spectra. It is found that the lower energy and the lower pressure is better for obtaining better emission spectra showing the possibility for determination of the analyte.

  17. lib and data: a new way of inhabiting the city

    Directory of Open Access Journals (Sweden)

    Dominique Boullier

    2014-01-01

    Full Text Available The Vélib bike rental system is worth analyzing in order to understand how cities move out of a model of large infrastructures towards a personal service principle connected to digital traceability and mapping of all activities. The new offer of bikes distributed all over the city creates a new map for access to mobility resources while introducing citizens to a “personal-public” device. Each feature of the system requires a very well designed information system to match the needs for bikes and to charge the users through cards (credit or transportation cards. Personal data is the essential entity that fuels the whole system and that creates potential privacy problems as well as monetization opportunities. The paper relies on a theoretical framework, called habitele, which accounts for the process of inhabiting that is now extended to the personal data ecosystem. The portability of mobile phones (and other devices such as cards creates an envelope that follows the urban citizen and equips all his activities while it makes a new layer of the city appear, adapted to the personal involvement in the urban environment

  18. Enhancing the Performance of LibSVM Classifier by Kernel F-Score Feature Selection

    Science.gov (United States)

    Sarojini, Balakrishnan; Ramaraj, Narayanasamy; Nickolas, Savarimuthu

    Medical Data mining is the search for relationships and patterns within the medical datasets that could provide useful knowledge for effective clinical decisions. The inclusion of irrelevant, redundant and noisy features in the process model results in poor predictive accuracy. Much research work in data mining has gone into improving the predictive accuracy of the classifiers by applying the techniques of feature selection. Feature selection in medical data mining is appreciable as the diagnosis of the disease could be done in this patient-care activity with minimum number of significant features. The objective of this work is to show that selecting the more significant features would improve the performance of the classifier. We empirically evaluate the classification effectiveness of LibSVM classifier on the reduced feature subset of diabetes dataset. The evaluations suggest that the feature subset selected improves the predictive accuracy of the classifier and reduce false negatives and false positives.

  19. Investigation of Laser Induced Breakdown Spectroscopy (LIBS) for the Differentiation of Nerve and Gland Tissue—A Possible Application for a Laser Surgery Feedback Control Mechanism

    Science.gov (United States)

    Mehari, F.; Rohde, M.; Knipfer, C.; Kanawade, R.; Klämpfl, F.; W., Adler; Oetter, N.; Stelzle, F.; Schmidt, M.

    2016-06-01

    Laser surgery provides clean, fast and accurate modeling of tissue. However, the inability to determine what kind of tissue is being ablated at the bottom of the cut may lead to the iatrogenic damage of structures that were meant to be preserved. In this context, nerve preservation is one of the key challenges in any surgical procedure. One example is the treatment of parotid gland pathologies, where the facial nerve (N. VII) and its main branches run through and fan out inside the glands parenchyma. A feedback system that automatically stops the ablation to prevent nerve-tissue damage could greatly increase the applicability and safety of surgical laser systems. In the present study, Laser Induced Breakdown Spectroscopy (LIBS) is used to differentiate between nerve and gland tissue of an ex-vivo pig animal model. The LIBS results obtained in this preliminary experiment suggest that the measured spectra, containing atomic and molecular emissions, can be used to differentiate between the two tissue types. The measurements and differentiation were performed in open air and under normal stray light conditions.

  20. New and rare species of anamorphic fungi for Poland

    Directory of Open Access Journals (Sweden)

    Beata Czerniawska

    2013-12-01

    Full Text Available Morphological characters of and disease symptoms caused by five fungal species parasitizing on plants of the Słowiński National Park and the Drawieński National Park (both located in north-western Poland are presented. Of the species, Ramularia celastri and Ascochyta irpina are new for Poland, and Ascochyta geraniicola, Phyllosticta caricis and Septoriella junci have earlier rarely been found in this country. Moreover, the latter three fungi were found on plants so far not reported in the literature to be their hosts. Finally, the known distribution of the fungi characterized in both Poland and the other regions of the world is presented.

  1. Impact socio professionnel de la libération chirurgicale du syndrome du canal carpien

    Science.gov (United States)

    Kraiem, Aouatef Mahfoudh; Hnia, Hajer; Bouzgarrou, Lamia; Henchi, Mohamed Adnène; Khalfallah, Taoufik

    2016-01-01

    L’objectif de notre travail était d’étudier les conséquences socioprofessionnelles d’une libération chirurgicale du SCC. Il s’agit d’une étude transversale portant sur les sujets opérés pour un SCC d’origine professionnelle ; recensés dans le Service de Médecine de Travail et de Pathologies Professionnelles au CHU Tahar Sfar de Mahdia en Tunisie sur une période de 8 ans allant du 1 Janvier 2006 au mois Décembre 2013. Le recueil des données s’est basé sur une fiche d’enquête, portant sur la description des caractéristiques socioprofessionnelles, médicales, et sur le devenir professionnel des participants. Pour étudier les contraintes psychosociales au travail, nous avons adopté le questionnaire de Karasek. La durée d’arrêt de travail après libération chirurgicale du SCC était significativement liée à l’existence d’autres troubles musculo-squelettiques autre que le SCC, la déclaration du SCC en maladie professionnelle et à l’ancienneté professionnelle des salariés. Quant au devenir professionnel des salariés opérés, 50,7% ont gardé le même poste, 15,3% ont bénéficié d’un aménagement de poste et 33,8% ont bénéficié d’un changement de poste dans la même entreprise. Le devenir professionnel de ces salariés était corrélé à leurs qualifications professionnelles et au type de l’atteinte sensitive et/ou motrice du nerf médian à l’EMG. Un certain nombre de facteurs non lésionnels déterminaient la durée de l’arrêt de travail, alors que le devenir professionnel des opérés pour SCC dépendait essentiellement de leurs qualifications professionnelles et des données de l’électromyogramme. Il est certain que des travaux beaucoup plus larges permettraient d’affiner encore ces résultats. PMID:27800089

  2. Vote for your favorite tourist attraction on "Le Dauphiné Libéré"

    CERN Multimedia

    2015-01-01

    Dear colleagues, During the summer, the French regional daily newspaper Le Dauphiné Libéré has been inviting its readers to vote for their favourite tourist attraction (natural or otherwise) in the Bellegarde area and the Pays de Gex, and CERN is one of the nominees. This is a great opportunity for us to communicate directly with people living in the region, particularly those who have not yet had the chance to visit CERN, and who, thanks to this survey, might be curious to learn more about the Laboratory and pay us a visit. Remember, visits to CERN are free of charge all year round! We invite you to vote for CERN by clicking on this link: http://www.ledauphine.com/ain/2015/07/10/votez-pur-votre-site-prefere-dans-le-bassin-bellegardien-et-le-pays-de-gex. We’re counting on your votes! CERN Local Communication team

  3. Digital content sewed together within a library catalogue WebLib - The CERN Document Server

    CERN Document Server

    Vigen, Jens

    2002-01-01

    Aggregation, harvesting, personalization techniques, portals, service provision, etc. have all become buzzwords. Most of them simply describing what librarians have been doing for hundreds of years. Prior to the Web few people outside the libraries were concerned about these issues, a situation which today it is completely turned upside down. Hopefully the new actors on the arena of knowledge management will take full advantage of all the available "savoir faire". At CERN, the European Organization for Nuclear Research, librarians and informaticians have set up a complete system, WebLib, actually based on the traditional library catalogue. Digital content is, within this framework, being integrated to the highest possible level in order to meet the strong requirements of the particle physics community. The paper gives an overview of the steps CERN has made towards the digital library from the day the laboratory conceived the World Wide Web to present.

  4. Cropland Field Monitoring: MMV Page 1 Montana Cropland Enrolled Farm Fields Carbon Sequestration Field Sampling, Measurement, Monitoring, and Verification: Application of Visible-Near Infrared Diffuse Reflectance Spectroscopy (VNIR) and Laser-induced Breakdown Spectroscopy (LIBS)

    Energy Technology Data Exchange (ETDEWEB)

    Lee Spangler; Ross Bricklemyer; David Brown

    2012-03-15

    There is growing need for rapid, accurate, and inexpensive methods to measure, and verify soil organic carbon (SOC) change for national greenhouse gas accounting and the development of a soil carbon trading market. Laboratory based soil characterization typically requires significant soil processing, which is time and resource intensive. This severely limits application for large-region soil characterization. Thus, development of rapid and accurate methods for characterizing soils are needed to map soil properties for precision agriculture applications, improve regional and global soil carbon (C) stock and flux estimates and efficiently map sub-surface metal contamination, among others. The greatest gains for efficient soil characterization will come from collecting soil data in situ, thus minimizing soil sample transportation, processing, and lab-based measurement costs. Visible and near-infrared diffuse reflectance spectroscopy (VisNIR) and laser-induced breakdown spectroscopy (LIBS) are two complementary, yet fundamentally different spectroscopic techniques that have the potential to meet this need. These sensors have the potential to be mounted on a soil penetrometer and deployed for rapid soil profile characterization at field and landscape scales. Details of sensor interaction, efficient data management, and appropriate statistical analysis techniques for model calibrations are first needed. In situ or on-the-go VisNIR spectroscopy has been proposed as a rapid and inexpensive tool for intensively mapping soil texture and organic carbon (SOC). While lab-based VisNIR has been established as a viable technique for estimating various soil properties, few experiments have compared the predictive accuracy of on-the-go and lab-based VisNIR. Eight north central Montana wheat fields were intensively interrogated using on-the-go and lab-based VisNIR. Lab-based spectral data consistently provided more accurate predictions than on-the-go data. However, neither in situ

  5. Fungi colonising the above-ground parts of fodder galega (Galega orientalis Lam. cultivated in pure sowing and mixed with smooth brome-grass (Bromus inermis Leyss.

    Directory of Open Access Journals (Sweden)

    Bożena Cwalina-Ambroziak

    2012-12-01

    Full Text Available Field experiments were carried out in 1999-2001 in the experimental field in Knopin near Dobre Miasto to determine the intensity of fodder galega diseases cultivated in pure sowing and mixed with smooth brome-grass (the Hillstrand and Auld' s modified scale, 1982. The fungi colonising the phyllosphere of fodder galega were analysed in a laboratory (Chruoeciak , 1974. The following symptoms were observed in fodder galega: ascochyta blight (Ascochyta sp., gray mould (Botrytis cinerea and plant wilting (Fusarium oxysporum.. The climatic conditions had an effect on the development of diseases. The greatest intensity of gray mould (Ii = 24.3% and plant wilting (17.9% of plants with the disease symptoms were observed in 2001. Ascochyta blight occurred with the lowest intensity and the highest infection index in 1999 in the cultivation of fodder galega mixed with smooth brome-grass was only 12.1%. The type of cultivation also modified fodder galega disease intensity. Gray mould and plant wilting developed better in pure sowing than in mixed sowing with smooth brome-grass. Throughout the entire experiment period the average infection index was 22.8% and 15.9% of plants with the wilt symptoms. Ascochyta blight found better conditions for development in plants cultivated in a mix with smooth brome-grass (average infection index - 10.0%. The fodder galega phyllosphere provided 4149 fungal isolates represented by 17 species and yeast-like fungi. Yeast-like fungi dominated (75.6% of the total isolates. The following species were less numerous: Botrytis cinerea, Humicola brevis, Acremonium strictum and Cladosporium cladosporioides. From the leaves of fodder galega cultivated in pure sowing, 3.8% more fungi were obtained than from the leaves of plants cultivated with a mix of smooth brome-grass, including more frequently isolated pathogenic fungi representing the genera of Fusarium and the species of Botrytis cinerea.

  6. Comparative Study of Elemental Nutrients in Organic and Conventional Vegetables Using Laser-Induced Breakdown Spectroscopy (LIBS).

    Science.gov (United States)

    Bhatt, Chet R; Alfarraj, Bader; Ghany, Charles T; Yueh, Fang Y; Singh, Jagdish P

    2017-04-01

    In this study, the laser-induced breakdown spectroscopy (LIBS) technique was used to identify and compare the presence of major nutrient elements in organic and conventional vegetables. Different parts of cauliflowers and broccolis were used as working samples. Laser-induced breakdown spectra from these samples were acquired at optimum values of laser energy, gate delay, and gate width. Both univariate and multivariate analyses were performed for the comparison of these organic and conventional vegetable flowers. Principal component analysis (PCA) was taken into account for multivariate analysis while for univariate analysis, the intensity of selected atomic lines of different elements and their intensity ratio with some reference lines of organic cauliflower and broccoli samples were compared with those of conventional ones. In addition, different parts of the cauliflower and broccoli were compared in terms of intensity and intensity ratio of elemental lines.

  7. LIBS detection of heavy metal elements in liquid solutions by using wood pellet as sample matrix

    International Nuclear Information System (INIS)

    Wen Guanhong; Sun Duixiong; Su Maogen; Dong Chenzhong

    2013-01-01

    Laser-induced breakdown spectroscopy (LIBS) has been applied to the analysis of heavy metals in liquid sample. A new approach was presented to improve the detection limit and minimize the sample matrix effects, in which dried wood pellets absorbed the given amounts of Cr standard solutions and then were baked because they have stronger and rapid absorption properties for liquid samples as well as simple elemental compositions. In this work, we have taken a typical heavy metal Cr element as an example, and investigated the spectral feasibility of Cr solutions and dried wood pellets before and after absorbing Cr solutions at the same experimental conditions, respectively. The results were demonstrated to successfully produce a superior analytical response for heavy metal elements by using wood pellet as sample matrix according to obtained LOD of 0.07 ppm for Cr element in solutions. (author)

  8. LIBS Detection of Heavy Metal Elements in Liquid Solutions by Using Wood Pellet as Sample Matrix

    International Nuclear Information System (INIS)

    Wen Guanhong; Sun Duixiong; Su Maogen; Dong Chenzhong

    2014-01-01

    Laser-induced breakdown spectroscopy (LIBS) has been applied to the analysis of heavy metals in liquid samples. A new approach was presented to lower the limit of detection (LOD) and minimize the sample matrix effects, in which dried wood pellets absorbed the given amounts of Cr standard solutions and then were baked because they have stronger and rapid absorption properties for liquid samples as well as simple elemental compositions. In this work, we have taken a typical heavy metal Cr element as an example, and investigated the spectral feasibility of Cr solutions and dried wood pellets before and after absorbing Cr solutions at the same experimental conditions. The results were demonstrated to successfully produce a superior analytical response for heavy metal elements by using wood pellet as sample matrix according to the obtained LOD of 0.07 ppm for Cr element in solutions

  9. Reliable classification of moving waste materials with LIBS in concrete recycling.

    Science.gov (United States)

    Xia, Han; Bakker, M C M

    2014-03-01

    Effective discrimination between different waste materials is of paramount importance for inline quality inspection of recycle concrete aggregates from demolished buildings. The moving targeted materials in the concrete waste stream are wood, PVC, gypsum block, glass, brick, steel rebar, aggregate and cement paste. For each material, up to three different types were considered, while thirty particles of each material were selected. Proposed is a reliable classification methodology based on integration of the LIBS spectral emissions in a fixed time window, starting from the deployment of the laser shot. PLS-DA (multi class) and the hybrid combination PCA-Adaboost (binary class) were investigated as efficient classifiers. In addition, mean centre and auto scaling approaches were compared for both classifiers. Using 72 training spectra and 18 test spectra per material, each averaged by ten shots, only PLS-DA achieved full discrimination, and the mean centre approach made it slightly more robust. Continuing with PLS-DA, the relation between data averaging and convergence to 0.3% average error was investigated using 9-fold cross-validations. Single-shot PLS-DA presented the highest challenge and most desirable methodology, which converged with 59 PC. The degree of success in practical testing will depend on the quality of the training set and the implications of the possibly remaining false positives. © 2013 Published by Elsevier B.V.

  10. Quantitative analysis of Al-Si alloy using calibration free laser induced breakdown spectroscopy (CF-LIBS)

    Science.gov (United States)

    Shakeel, Hira; Haq, S. U.; Aisha, Ghulam; Nadeem, Ali

    2017-06-01

    The quantitative analysis of the standard aluminum-silicon alloy has been performed using calibration free laser induced breakdown spectroscopy (CF-LIBS). The plasma was produced using the fundamental harmonic (1064 nm) of the Nd: YAG laser and the emission spectra were recorded at 3.5 μs detector gate delay. The qualitative analysis of the emission spectra confirms the presence of Mg, Al, Si, Ti, Mn, Fe, Ni, Cu, Zn, Sn, and Pb in the alloy. The background subtracted and self-absorption corrected emission spectra were used for the estimation of plasma temperature as 10 100 ± 300 K. The plasma temperature and self-absorption corrected emission lines of each element have been used for the determination of concentration of each species present in the alloy. The use of corrected emission intensities and accurate evaluation of plasma temperature yield reliable quantitative analysis up to a maximum 2.2% deviation from reference sample concentration.

  11. Microparticules composites lipide-silice pour la libération prolongée d'un principe actif dans l'estomac.

    OpenAIRE

    Perge , Laurent; Robitzer , Mike; Quignard , Françoise; Devoisselle , Jean-Marie; Legrand , Philippe

    2010-01-01

    International audience; Ces dernières années, les avancés scientifiques et technologiques ont été menées dans le développement de systèmes par voie orale à libération contrôlée de principe actif indépendants du ntemps de transit dans le tractus digestif et capables de résider plus longtemps dans l'estomac en évitant une vidange gastrique prématurée. Différentes approches ont été développées pour permettre de surpasser ces problèmes, comme des systèmes flottants, des systèmes polymères bioadhé...

  12. [6-chloro-3-pyridylmethyl-3H]neonicotinoids as high-affinity radioligands for the nicotinic acetylcholine receptor: preparation using NaB3H4 and LiB3H4

    International Nuclear Information System (INIS)

    Latli, Bachir; Casida, J.E.

    1996-01-01

    NaB 3 H 4 and LiB 3 H 4 at 78% and 97% isotopic enrichments, respectively, were used in the synthesis of 3 H-labeled 1-(6-chloro-3-pyridyl)-methyl-2-nitromethyleneimidazolidine (CH-IMI) and N'-[(6-chloro-3-pyridyl)methyl]-n''-cyano-n'-methylacetamidine (acetamiprid) (two very potent insecticides) and of 1-(6-chloro-3-pyridyl)methyl-2-iminoimidazolidine (desnitro-IMI) (a metabolite of the commercial insecticides imidacloprid). 6-Chloronicotinoyl chloride was treated with either NaB 3 H 4 in methanol or LiB 3 H 4 in tetrahydrofuran and the resulting alcohol transformed to 2-chloro-5-chloromethylpyridine, which was then coupled to N-cyano-N'-methylacetamidine to give [ 3 H] acetamiprid (45 Ci/mmol). 2-Chloro-5-chloro[ 3 H]methylpyridine was also reacted with ethylenediamine and the product was either refluxed in absolute ethanol with 1,1-bis(methylthio)-2-nitro-ethylene to provide [ 3 H]CH-IMI or reacted in toluene with a solution of cyanogen bromide to produce [ 3 H] desnitro-IMI (each 55 Ci/mmol. (author)

  13. Screening of ten advanced chickpea lines for blight and wilt resistance

    International Nuclear Information System (INIS)

    Jamil, F.F.; Haq, I.; Sarwar, N.; Alam, S.S.; Khan, J.A.; Hanif, M.; Khan, I.A.; Sarwar, M.; Haq, M.A.

    2002-01-01

    Ten advanced chickpea lines developed at NIAB were screened for resistance to Ascochyta blight and Fusarium wilt diseases in different sets of experiments conducted under controlled environment. Inoculation of plants by spore suspension of virulent strains of Ascochyta rabiei revealed that one line (97313) was resistant tolerant, two lines (97305, 97392) were tolerant, six lines (97306, 97310, 97311, 97303, 97302, 97393) were tolerant/susceptible and one line (97301) was susceptible. Screening of the same lines against Fusarium wilt by water culture method showed that two lines (97301, 97313) were moderately resistant, four lines (97302, 97303, 97306, 97393) were tolerant and the remaining four lines were susceptible. Screening through phytotoxic culture filtrates revealed that two lines (97302, 97313) were less sensitive to culture filtrates of Ascochyta rabiei and Fusarium oxysporum than the resistant check (CM88). These lines were also analyzed spectrophotometrically for peroxidase enzyme activity. Maximum enzyme activity was detected after 48 hours of inoculation with A. rabiei in three lines (97305, 97311, 97313) and resistant check (CM88) while enzyme activity in the remaining lines reached its maximum after 72 hours of inoculation which was comparable to the susceptible check (Pb-1). These studies lead to the conclusion that one line (97313) exhibited resistance against both the diseases and can be used as a source of resistance for further improvement of chickpea germplasm. (author)

  14. Short Communication on “Direct compositional quantification of (U-Th)O{sub 2} - MOX nuclear fuel using ns-UV-LIBS and chemometric regression models”

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Manjeet [Fuel Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Sarkar, Arnab, E-mail: arnab@barc.gov.in [Fuel Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Mao, Xianglei; Russo, Richard E. [Lawrence Berkeley National Laboratory, University of California, Berkeley, CA 94720 (United States)

    2017-02-15

    The determination of uranium with composition varying from 0% to 35 wt% in (Th-U)O{sub 2} mixed oxide fuel using laser induced breakdown spectroscopy (LIBS) utilizing partial least square regression (PLSR) has been demonstrated. Good agreement between expected and experiment results using 266 nm, 532 nm and 1064 nm was shown. The analytical results at 266 nm of 2–3% precision and ∼1% accuracy (bias) satisfy the acceptance criteria range for chemical analysis in the nuclear industry.

  15. EFFECTS OF THE NICOTINIC RECEPTOR ANTAGONIST MECAMYLAMINE ON AD-LIB SMOKING BEHAVIOR, TOPOGRAPHY, AND NICOTINE LEVELS IN SMOKERS WITH AND WITHOUT SCHIZOPHRENIA: A PRELIMINARY STUDY

    OpenAIRE

    McKee, Sherry A.; Weinberger, Andrea H.; Harrison, Emily L. R.; Coppola, Sabrina; George, Tony P.

    2009-01-01

    Individuals with schizophrenia have higher plasma nicotine levels in comparison to non-psychiatric smokers, even when differences in smoking are equated. This difference may be related to how intensely cigarettes are smoked but this has not been well-studied. Mecamylamine (MEC), a non-competitive nicotinic acetylcholine receptor (nAChR) antagonist, which has been shown to increase ad-lib smoking and to affect smoking topography, was used in the current study as a pharmacological probe to incr...

  16. Discovery of a Novel er1 Allele Conferring Powdery Mildew Resistance in Chinese Pea (Pisum sativum L.) Landraces

    Science.gov (United States)

    Sun, Suli; Fu, Haining; Wang, Zhongyi; Duan, Canxing; Zong, Xuxiao; Zhu, Zhendong

    2016-01-01

    Pea powdery mildew, caused by Erysiphe pisi D.C., is an important disease worldwide. Deployment of resistant varieties is the main way to control this disease. This study aimed to screen Chinese pea (Pisum sativum L.) landraces resistant to E. pisi, and to characterize the resistance gene(s) at the er1 locus in the resistant landraces, and to develop functional marker(s) specific to the novel er1 allele. The 322 landraces showed different resistance levels. Among them, 12 (3.73%), 4 (1.24%) and 17 (5.28%) landraces showed immunity, high resistance and resistance to E. pisi, respectively. The other landraces appeared susceptible or highly susceptible to E. pisi. Most of the immune and highly resistant landraces were collected from Yunnan province. To characterize the resistance gene at the er1 locus, cDNA sequences of PsMLO1 gene were determined in 12 immune and four highly resistant accessions. The cDNAs of PsMLO1 from the immune landrace G0005576 produced three distinct transcripts, characterized by a 129-bp deletion, and 155-bp and 220-bp insertions, which were consistent with those of er1-2 allele. The PsMLO1 cDNAs in the other 15 resistant landraces produced identical transcripts, which had a new point mutation (T→C) at position 1121 of PsMLO1, indicating a novel er1 allele, designated as er1-6. This mutation caused a leucine to proline change in the amino acid sequence. Subsequently, the resistance allele er1-6 in landrace G0001778 was confirmed by resistance inheritance analysis and genetic mapping on the region of the er1 locus using populations derived from G0001778 × Bawan 6. Finally, a functional marker specific to er1-6, SNP1121, was developed using the high-resolution melting technique, which could be used in pea breeding via marker-assisted selection. The results described here provide valuable genetic information for Chinese pea landraces and a powerful tool for pea breeders. PMID:26809053

  17. LIBS, Raman spectroscopy, and optical microscopy analyses of superficial encrustations on ancient tesserae in Lebanon

    Science.gov (United States)

    Tomkowska, Anna; Chmielewski, Krzysztof; Skrzyczanowski, Wojciech; Mularczyk-Oliwa, Monika; Ostrowski, Roman; Strzelec, Marek

    2017-07-01

    The aim of research was determination of composition and nature of superficial deposits, cumulated at the selected mosaic's tesserae from Lebanon. Selected were three series of objects from different locations, namely from the seaside and mountain archaeological sites as well as from the mosaics exposed in the city center. Analyzed were stone and ceramic tesserae. The selection of objects was dictated by wide diversification of factors influencing the state of preservation and composition of deposits in given location. Investigations were performed including LIBS, FT-IR, Raman spectroscopy and optical 3D microscopy. The experimental results included composition and kind of deposit at the tesserae surfaces, and composition of tesserae itself. Compounds in the superficial deposits were identified. Confirmed was occurrence of different encrustations in dependence on geographic localization of a given sample. The interpretation of results was supported by multivariate statistical techniques, especially by the factor analysis. Performed analyses constitute the pioneer realization in terms of determination of deposits composition at the surface of mosaics from the Lebanon territory.

  18. Effect of applied voltage and inter-pulse delay in spark-assisted LIBS

    Science.gov (United States)

    Robledo-Martinez, A.; Sobral, H.; Garcia-Villarreal, A.

    2018-06-01

    We report the results obtained in an investigation on the effect of the time delay between the laser and electrical pulses in a spark-assisted laser-induced breakdown spectroscopy (LIBS) experiment. The electrical discharge is produced by the discharge of a charged coaxial cable. This arrangement produces a fast unipolar current pulse (500 ns) that applies high power ( 600 kW) to the laser ablation plasma. The delay between the laser pulse and the electric pulse can be controlled at will in order to find the optimal time in terms of enhancement of the emitted lines. It was found that the application of the high voltage pulse enhances the ionic lines emitted by up to two orders of magnitude. An additional enhancement by a factor of 2-4 can be obtained delaying the application of the electric pulse by a time of 0.6-20 μs. In the tests it was noticed that the ionic lines were found to be clearly responsive to increments in the applied electric energy while the neutral lines did so marginally. Our results show that the intensification of the lines is mainly due to reheating of the ablation plasma as the application of the electrical pulse increments the temperature of the ablation plasma by about 50%. It is demonstrated that the present technique is an efficient way of intensifying the lines emitted without incurring in additional damage to the sample.

  19. Calibration strategies for the direct determination of Ca, K, and Mg in commercial samples of powdered milk and solid dietary supplements using laser-induced breakdown spectroscopy (LIBS).

    Science.gov (United States)

    Dos Santos Augusto, Amanda; Barsanelli, Paulo Lopes; Pereira, Fabiola Manhas Verbi; Pereira-Filho, Edenir Rodrigues

    2017-04-01

    This study describes the application of laser-induced breakdown spectroscopy (LIBS) for the direct determination of Ca, K and Mg in powdered milk and solid dietary supplements. The following two calibration strategies were applied: (i) use of the samples to calculate calibration models (milk) and (ii) use of sample mixtures (supplements) to obtain a calibration curve. In both cases, reference values obtained from inductively coupled plasma optical emission spectroscopy (ICP OES) after acid digestion were used. The emission line selection from LIBS spectra was accomplished by analysing the regression coefficients of partial least squares (PLS) regression models, and wavelengths of 534.947, 766.490 and 285.213nm were chosen for Ca, K and Mg, respectively. In the case of the determination of Ca in supplements, it was necessary to perform a dilution (10-fold) of the standards and samples to minimize matrix interference. The average accuracy for powdered milk ranged from 60% to 168% for Ca, 77% to 152% for K and 76% to 131% for Mg. In the case of dietary supplements, standard error of prediction (SEP) varied from 295 (Mg) to 3782mgkg -1 (Ca). The proposed method presented an analytical frequency of around 60 samples per hour and the step of sample manipulation was drastically reduced, with no generation of toxic chemical residues. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Use of multivariate statistical tool for data processing in the analysis of Cu, Cr, Fe, Pb, Mo and Mg in lubricating oil by LIBS

    International Nuclear Information System (INIS)

    Alves, Luana F.N.; Sarkis, Jorge E.S.; Bordon, Isabela C.A.C.

    2015-01-01

    Analysis of industrial lubricants is widely used for monitoring and predicting maintenance requirements in a broad range of mechanical systems. Laser induced breakdown spectroscopy has been used to evaluate the potentiality of the technique for the determination of metals in lubricating oils. Prior to quantitative analysis, the LIBS system was calibrated using standard samples containing the elements investigated (Cu, Cr, Fe, Pb, Mo and Mg). This study presents the usefulness of multivariate statistical techniques for evaluation and interpretation of large complex data sets in order to get more information about concentration of metals in oils lubricants is related to engine wear. (author)

  1. Reconstructing Ancient Egyptian Diet through Bone Elemental Analysis Using LIBS (Qubbet el Hawa Cemetery

    Directory of Open Access Journals (Sweden)

    Ghada Darwish Al-Khafif

    2015-01-01

    Full Text Available One of the most important advantages of LIBS that make it suitable for the analysis of archeological materials is that it is a quasi-nondestructive technique. Archeological mandibles excavated from Qubbet el Hawa Cemetery, Aswan, were subjected to elemental analysis in order to reconstruct the dietary patterns of the middle class of the Aswan population throughout three successive eras: the First Intermediate Period (FIP, the Middle Kingdom (MK, and the Second Intermediate Period (SIP. The bone Sr/Ca and Ba/Ca ratios were significantly correlated, so the Sr/Ca ratios are considered to represent the ante-mortem values. It was suggested that the significantly low FIP Sr/Ca compared to that of both the MK and the SIP was attributed to the consumption of unusual sorts of food and imported cereals during years of famine, while the MK Sr/Ca was considered to represent the amelioration of climatic, social, economic, and political conditions in this era of state socialism. The SIP Sr/Ca, which is nearly the same as that of the MK, was considered to be the reflection of the continuity of the individualism respect and state socialism and a reflection of agriculture conditions amelioration under the reign of the 17th Dynasty in Upper Egypt.

  2. Calibration of the Fluorine, Chlorine and Hydrogen Content of Apatites With the ChemCam LIBS Instrument

    Science.gov (United States)

    Meslin, P.-Y.; Cicutto, L.; Forni, O.; Drouet, C.; Rapin, W.; Nachon, M.; Cousin, A.; Blank, J. G.; McCubbin, F. M.; Gasnault, O.; hide

    2016-01-01

    Determining the composition of apatites is important to understand the behavior of volatiles during planetary differentiation. Apatite is an ubiquitous magmatic mineral in the SNC meteorites. It is a significant reservoir of halogens in these meteorites and has been used to estimate the halogen budget of Mars. Apatites have been identified in sandstones and pebbles at Gale crater by ChemCam, a Laser-Induced Breakdown Spectroscometer (LIBS) instrument onboard the Curiosity rover. Their presence was inferred from correlations between calcium, fluorine (using the CaF molecular band centered near 603 nm, whose detection limit is much lower that atomic or ionic lines and, in some cases, phosphorus (whose detection limit is much larger). An initial quantification of fluorine, based on fluorite (CaF2)/basalt mixtures and obtained at the LANL laboratory, indicated that the excess of F/Ca (compared to the stoichiometry of pure fluorapatites) found on Mars in some cases could be explained by the presence of fluorite. Chlorine was not detected in these targets, at least above a detection limit of 0.6 wt% estimated from. Fluorapatite was later also detected by X-ray diffraction (with CheMin) at a level of approx.1wt% in the Windjana drill sample (Kimberley area), and several points analyzed by ChemCam in this area also revealed a correlation between Ca and F. The in situ detection of F-rich, Cl-poor apatites contrasts with the Cl-rich, F-poor compositions of apatites found in basaltic shergottites and in gabbroic clasts from the martian meteorite NWA 7034, which were also found to be more Cl-rich than apatites from basalts on Earth, the Moon, or Vesta. The in situ observations could call into question one of the few possible explanations brought forward to explain the SNC results, namely that Mars may be highly depleted in fluorine. The purpose of the present study is to refine the calibration of the F, Cl, OH and P signals measured by the ChemCam LIBS instrument, initiated

  3. Effects of the nicotinic receptor antagonist mecamylamine on ad-lib smoking behavior, topography, and nicotine levels in smokers with and without schizophrenia: a preliminary study.

    Science.gov (United States)

    McKee, Sherry A; Weinberger, Andrea H; Harrison, Emily L R; Coppola, Sabrina; George, Tony P

    2009-12-01

    Individuals with schizophrenia have higher plasma nicotine levels in comparison to non-psychiatric smokers, even when differences in smoking are equated. This difference may be related to how intensely cigarettes are smoked but this has not been well studied. Mecamylamine (MEC), a non-competitive nicotinic acetylcholine receptor (nAChR) antagonist, which has been shown to increase ad-lib smoking and to affect smoking topography, was used in the current study as a pharmacological probe to increase our understanding of smoking behavior, smoking topography, and resulting nicotine levels in smokers with schizophrenia. This preliminary study used a within-subject, placebo-controlled design in smokers with schizophrenia (n=6) and healthy control smokers (n=8) to examine the effects of MEC (10mg/day) on ad-lib smoking behavior, topography, nicotine levels, and tobacco craving across two smoking deprivation conditions (no deprivation and 12-h deprivation). MEC, compared to placebo, increased the number of cigarettes smoked and plasma nicotine levels. MEC increased smoking intensity and resulted in greater plasma nicotine levels in smokers with schizophrenia compared to controls, although these results were not consistent across deprivation conditions. MEC also increased tobacco craving in smokers with schizophrenia but not in control smokers. Our results suggest that antagonism of high-affinity nAChRs in smokers with schizophrenia may prompt compensatory smoking, increasing the intensity of smoking and nicotine exposure without alleviating craving. Further work is needed to assess whether nicotine levels are directly mediated by how intensely the cigarettes are smoked, and to confirm whether this effect is more pronounced in smokers with schizophrenia.

  4. LibHalfSpace: A C++ object-oriented library to study deformation and stress in elastic half-spaces

    Science.gov (United States)

    Ferrari, Claudio; Bonafede, Maurizio; Belardinelli, Maria Elina

    2016-11-01

    The study of deformation processes in elastic half-spaces is widely employed for many purposes (e.g. didactic, scientific investigation of real processes, inversion of geodetic data, etc.). We present a coherent programming interface containing a set of tools designed to make easier and faster the study of processes in an elastic half-space. LibHalfSpace is presented in the form of an object-oriented library. A set of well known and frequently used source models (Mogi source, penny shaped horizontal crack, inflating spheroid, Okada rectangular dislocation, etc.) are implemented to describe the potential usage and the versatility of the library. The common interface given to library tools enables us to switch easily among the effects produced by different deformation sources that can be monitored at the free surface. Furthermore, the library also offers an interface which simplifies the creation of new source models exploiting the features of object-oriented programming (OOP). These source models can be built as distributions of rectangular boundary elements. In order to better explain how new models can be deployed some examples are included in the library.

  5. Determination of Metal Elements in Wine Using Laser-Induced Breakdown Spectroscopy (LIBS).

    Science.gov (United States)

    Bocková, Jana; Tian, Ye; Yin, Hualiang; Delepine-Gilon, Nicole; Chen, Yanping; Veis, Pavel; Yu, Jin

    2017-08-01

    We developed a method for sensitive elemental analysis of wines using laser-induced breakdown spectroscopy (LIBS). In order to overcome the inefficiency of direct ablation of bulk wine (an organic liquid), a thin layer of wine residue was prepared on a metallic target according to an appropriated heating procedure applied to an amount of liquid wine dropped on the target surface. The obtained ensemble was thus ablated. Such a sample preparation procedure used a very small volume of 2 mL of wine and took only 30 min without reagent or solvent. The results show the detection of tens of metal and non-metal elements including majors (Na, Mg, K, Ca), minors, and traces (Li, B, Si, P, Ti, Mn, Fe, Cu, Zn, Rb, Sr, Ba, and Pb) in wines purchased from local supermarkets and from different production places in France. Commercially available wines were then spiked with certified standard solutions of Ti and Fe. Three series of laboratory reference samples were thus prepared using three different wines (a red wine and a white wine from a same production region and a red wine from another production region) with concentrations of Ti and Fe in the range of 1-40 mg/L. Calibration graphs established with the spiked samples allowed extracting the figures-of-merit parameters of the method for wine analysis such as the coefficient of determination ( R 2 ) and the limits of detection and quantification (LOD and LOQ). The calibration curves built with the three wines were then compared. We studied the residual matrix effect between these wines in the determination of the concentrations of Ti and Fe.

  6. La peur blanche: un moteur de la politique éducative libérale en Bolivie (1899-1920

    Directory of Open Access Journals (Sweden)

    1998-01-01

    Full Text Available Quand le Parti Libéral arriva au pouvoir en Bolivie en 1899, il entreprit une politique éducative destinée tout à la fois à moderniser la société bolivienne et à l’unifier. Or cette politique éducative fut dictée non seulement par ces ambitions nationales libérales, mais aussi par la peur de toute une élite occidentalisée dans ses modes de vie et façons de penser, face au “danger indien” tel qu’elle se le représentait. Cette étude se propose de montrer comment cette peur conditionna une certaine politique éducative, qui chercha à intégrer les populations indiennes à l’unité nationale en en faisant des patriotes et en les désindianisant. EL MIEDO CERVAL DE LA ÉLITE BLANCA: UN MOTOR DE LA POLÍTICA EDUCATIVA LIBERAL EN BOLIVIA (1899-1920. En 1899, cuando llegó al poder el Partido Liberal, emprendió una política educativa destinada tanto a modernizar la sociedad boliviana como a unificarla. Ahora bien, esa política educativa la dictaron no sólo esas ambiciones nacionales liberales, sino también el miedo que sentía la élite en su conjunto, occidentalizada en sus modales y pensamientos, ante el “peligro indio” tal como ella se lo representaba. Este análisis se propone mostrar cómo este miedo condicionó una política educativa específica que buscó integrar a las poblaciones indígenas en una unidad nacional, haciéndolas patriotas a la par que desindianizándolas. WHITE RACE’S FEAR: A MOTIVE FOR THE LIBERAL EDUCATIVE POLICY IN BOLIVIA (1899-1920. When the Liberal Party came to power in 1899, it initiated an educational policy whose main objectives consisted to modernizing the Bolivian society and unify it. This educative policy was not only developed by those national liberal ambitions, but also emerged from an fear of the whole elite, westernized in its lifestyle and way of thinking, of what they called the “Indian threat”. The purpose of this study is to show how that fear has lead to the generation of a

  7. Pea disease diagnostic series - Powdery Mildew

    Science.gov (United States)

    Powdery mildew is a serious disease of pea worldwide, and it could be caused by two fungal species Erysiphe pisi and E. trifolii. White powdery patches on leaves, stems and pods are characteristics of the disease. The pathogen may form black fruiting bodies called chasmothecia near the end of the gr...

  8. KASP assays for powdery mildew resistance breeding in pea

    Science.gov (United States)

    Powdery mildew of pea, caused by Erysiphe pisi DC, is a serious production constraint to pea (Pisum sativum L.) production in the U.S. and elsewhere. Utilization of genetic resistance to powdery mildew using er1 has been an effective strategy to manage this disease. This gene, er1, conferring powde...

  9. Construction of a predictive model for concentration of nickel and vanadium in vacuum residues of crude oils using artificial neural networks and LIBS.

    Science.gov (United States)

    Tarazona, José L; Guerrero, Jáder; Cabanzo, Rafael; Mejía-Ospino, E

    2012-03-01

    A predictive model to determine the concentration of nickel and vanadium in vacuum residues of Colombian crude oils using laser-induced breakdown spectroscopy (LIBS) and artificial neural networks (ANNs) with nodes distributed in multiple layers (multilayer perceptron) is presented. ANN inputs are intensity values in the vicinity of the emission lines 300.248, 301.200 and 305.081 nm of the Ni(I), and 309.310, 310.229, and 311.070 nm of the V(II). The effects of varying number of nodes and the initial weights and biases in the ANNs were systematically explored. Average relative error of calibration/prediction (REC/REP) and average relative standard deviation (RSD) metrics were used to evaluate the performance of the ANN in the prediction of concentrations of two elements studied here. © 2012 Optical Society of America

  10. Al-Ghâlibûn Le Hezbollah et la mise en récit de la « société de la résistance » au Liban

    Directory of Open Access Journals (Sweden)

    Erminia Chiara Calabrese

    2014-07-01

    Full Text Available Après la libération du Sud Liban en 2000, la prise de conscience par le Hezbollah de l’importance de l’audiovisuel, bien plus que du cinéma, a conduit la direction du parti à placer, plus que jamais, la télévision au centre de son dispositif d’intervention pour influencer l’opinion publique. La télévision devait mobiliser la communauté chiite libanaise pour adhérer à ce que le parti appelle la « société de la résistance ». C’est dans ce contexte qui s’inscrit la réalisation de la série Al-Ghâlibûn [Les Victorieux] qui retrace les premières années de la résistance islamique (1982-1985 contre l’occupant israélien au Liban. Notre article propose une analyse de la dimension symbolique et sociopolitique de la série qui participe à l’entretien des mythes fédérateurs du Hezbollah. Plusieurs thèmes évoqués dans les différents épisodes de la série mettent en scène un choix de vie alternative proposé par le parti où la résistance contre l’occupant israélien devient une mission, une cause.

  11. Detecteur multibandes libs a base de reseaux holographiques epais: Conception optomecanique et gestion de l'innovation

    Science.gov (United States)

    Gagnon, Daniel

    Detection of sulfur by optical emission spectroscopy generally presents difficulties because the strongest lines are in the vacuum ultraviolet and therefore are readily absorbed by oxygen molecules in air. A novel concept for a low cost and efficient system to detect sulfur using near infrared lines by Laser-Induced Breakdown Spectroscopy is proposed in this thesis. The concept proposes to use customized thick holographic gratings, also referred as Volume Bragg Grating, for spectral filtering of the plasma light, and built-in custom electronics that amplify and integrate photodiodes output signals. In this work, the optomechanical design, manufacturing and trials of a multiband sensor's prototype is reviewed. Preliminary results has been presented at NASLIBS 2011 and showed a limit of detection comparable to that of a conventional high-end system. An article describing the concept and results has been published in a special issue of the Applied Optics journal. To turn this newly patented concept into commercial success, the management of the innovation has been performed by proposing strategic and tactic alliances for commercialisation purposes applied to strategic business positioning structured along the 3 axis Technology -- Product -- Market. Open innovation is here acting as the paradigm to efficiently reach the market. Discussion relative to strategic and tactic alliance is actually taking place for deployment of the LIBS multiband sensor in the mining industry.

  12. Standard Reference Line Combined with One-Point Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) to Quantitatively Analyze Stainless and Heat Resistant Steel.

    Science.gov (United States)

    Fu, Hongbo; Wang, Huadong; Jia, Junwei; Ni, Zhibo; Dong, Fengzhong

    2018-01-01

    Due to the influence of major elements' self-absorption, scarce observable spectral lines of trace elements, and relative efficiency correction of experimental system, accurate quantitative analysis with calibration-free laser-induced breakdown spectroscopy (CF-LIBS) is in fact not easy. In order to overcome these difficulties, standard reference line (SRL) combined with one-point calibration (OPC) is used to analyze six elements in three stainless-steel and five heat-resistant steel samples. The Stark broadening and Saha - Boltzmann plot of Fe are used to calculate the electron density and the plasma temperature, respectively. In the present work, we tested the original SRL method, the SRL with the OPC method, and intercept with the OPC method. The final calculation results show that the latter two methods can effectively improve the overall accuracy of quantitative analysis and the detection limits of trace elements.

  13. Third harmonic frequency generation by type-I critically phase-matched LiB3O5 crystal by means of optically active quartz crystal.

    Science.gov (United States)

    Gapontsev, Valentin P; Tyrtyshnyy, Valentin A; Vershinin, Oleg I; Davydov, Boris L; Oulianov, Dmitri A

    2013-02-11

    We present a method of third harmonic generation at 355 nm by frequency mixing of fundamental and second harmonic radiation of an ytterbium nanosecond pulsed all-fiber laser in a type-I phase-matched LiB(3)O(5) (LBO) crystal where originally orthogonal polarization planes of the fundamental and second harmonic beams are aligned by an optically active quartz crystal. 8 W of ultraviolet light at 355 nm were achieved with 40% conversion efficiency from 1064 nm radiation. The conversion efficiency obtained in a type-I phase-matched LBO THG crystal was 1.6 times higher than the one achieved in a type-II LBO crystal at similar experimental conditions. In comparison to half-wave plates traditionally used for polarization alignment the optically active quartz crystal has much lower temperature dependence and requires simpler optical alignment.

  14. Development and testing of an interface between measurement logging system and automation software DIAdem of National Instruments(NI) and water/steam material property library LibIF97

    International Nuclear Information System (INIS)

    Pietruske, H.; Schaffrath, A.

    2002-08-01

    The Institute of Safety Research (IfS) of the Forschungszentrum Rossendorf (FZR) e.V. is constructing a new large-scale multipurpose test facility TOPFLOW (Transient Two Phase Flow Test Facility). This facility will be probably put into operation in the next two months. For an effective evaluation of the start up experiments and the acceptance trials against the vendors FZR starts with the preparation of automated software tools for the measurement data logging and automation software DIAdem, which is distributed by National Instruments (NI). In a first step an interface for the coupling of a water/steam material property library LibIF97 of the University of Applied Science Zittau/Goerlitz was developed. This report describes the programming of the General Control Interface (GPI) and its coupling with DIAdem. Additionally the capability of this coupling in connection with autosequences for data evaluation was investigated. Furtheron effective methods for TOPFLOW data evaluation were demonstrated and tested against a concrete example. Currently no TOPFLOW data are available. Therefore one selected NOKO experiment was evaluated and first practical experiences were collected. Even this example is easy understandable and clearly seen, it contains every step, which is necessary for the TOPFLOW data evaluation. This contains the opening of files, determination of water/steam material properties with the Dynamic-Link-Library LibIF97.dII, the linkage of different data channels and the generation of layouts for graphics and reports. The tools presented in this report are an important step for the evaluation of the experimental data of TOPFLOW. These tools will be adapted now for the assessment of the acceptance trails. Further on now the generation of the automated software sequences for the first scientific tests are developed. (orig.) [de

  15. Le rapport judéo-arabe dans le roman de Abraham B. Yehoshua : La Mariée libérée The Jewish-Arab Relationship in the Novel by Abraham B. Yehoshua, The Liberated Wife (“La Mariée libérée” יחסי יהודים-ערבים ברומן "הכלה המשוחררת" לא. ב. יהושע

    Directory of Open Access Journals (Sweden)

    Françoise Saquer-Sabin

    2012-06-01

    Full Text Available Ce roman particulièrement « imprégné » d’autonomie palestinienne, La mariée libérée présente un aperçu très original de l'expression de relations judéo-arabes en Israël. Pour la première fois, le choix littéraire met les personnages juifs et arabes sur un pied d'égalité. Par exemple, dans la partie principale du texte, des dialogues en arabe (traduit dans les notes de bas de page en hébreu s'efforcent de rendre les véritables paroles des Palestiniens. L'interaction entre les deux parties varie aussi d’après les thèmes, avec une alternance des rôles du dominant et du dominé selon les lieux et les territoires. Toutefois, traverser les frontières n'est pas sans danger pour l'intégrité de chaque personne, même si c’est un moyen de briser le mur des malentendus, et la conclusion en serait l'effondrement symbolique de l'identité nationale.A novel definitely steeped in Palestinian autonomy, “La mariée libérée” presents very original insights into the expression of Jewish-Arab relationships in Israel. For the first time, the literary choices put Jewish and Arab characters on an equal footing. For example, in the main part of the text, dialogues in Arabic (translated in footnotes into Hebrew strive to give the true spoken words of Palestinians. The interaction between the two parties is also at play trough the themes with alternating roles of the dominator and dominated according to the geographical territories. However, crossing the boundaries, is not without danger for each person’s integrity even if it breaks the wall of misunderstandings, and the conclusion is the symbolic collapse of national identity.רומן זה מציג מבט מקורי על יחסי היהודים והערבים בישראל ובשטחים. זו הפעם הראשונה שיצירה ישראלית מציגה אותם על מישור אחד, כאשר, כדוגמה, הטקסט כולל קטעים ארוכים בערבית (מת

  16. 2D evaluation of spectral LIBS data derived from heterogeneous materials using cluster algorithm

    Science.gov (United States)

    Gottlieb, C.; Millar, S.; Grothe, S.; Wilsch, G.

    2017-08-01

    Laser-induced Breakdown Spectroscopy (LIBS) is capable of providing spatially resolved element maps in regard to the chemical composition of the sample. The evaluation of heterogeneous materials is often a challenging task, especially in the case of phase boundaries. In order to determine information about a certain phase of a material, the need for a method that offers an objective evaluation is necessary. This paper will introduce a cluster algorithm in the case of heterogeneous building materials (concrete) to separate the spectral information of non-relevant aggregates and cement matrix. In civil engineering, the information about the quantitative ingress of harmful species like Cl-, Na+ and SO42- is of great interest in the evaluation of the remaining lifetime of structures (Millar et al., 2015; Wilsch et al., 2005). These species trigger different damage processes such as the alkali-silica reaction (ASR) or the chloride-induced corrosion of the reinforcement. Therefore, a discrimination between the different phases, mainly cement matrix and aggregates, is highly important (Weritz et al., 2006). For the 2D evaluation, the expectation-maximization-algorithm (EM algorithm; Ester and Sander, 2000) has been tested for the application presented in this work. The method has been introduced and different figures of merit have been presented according to recommendations given in Haddad et al. (2014). Advantages of this method will be highlighted. After phase separation, non-relevant information can be excluded and only the wanted phase displayed. Using a set of samples with known and unknown composition, the EM-clustering method has been validated regarding to Gustavo González and Ángeles Herrador (2007).

  17. Analytical Methods to Distinguish the Positive and Negative Spectra of Mineral and Environmental Elements Using Deep Ablation Laser-Induced Breakdown Spectroscopy (LIBS).

    Science.gov (United States)

    Kim, Dongyoung; Yang, Jun-Ho; Choi, Soojin; Yoh, Jack J

    2018-01-01

    Environments affect mineral surfaces, and the surface contamination or alteration can provide potential information to understanding their regional environments. However, when investigating mineral surfaces, mineral and environmental elements appear mixed in data. This makes it difficult to determine their atomic compositions independently. In this research, we developed four analytical methods to distinguish mineral and environmental elements into positive and negative spectra based on depth profiling data using laser-induced breakdown spectroscopy (LIBS). The principle of the methods is to utilize how intensity varied with depth for creating a new spectrum. The methods were applied to five mineral samples exposed to four environmental conditions including seawater, crude oil, sulfuric acid, and air as control. The proposed methods are then validated by applying the resultant spectra to principal component analysis and data were classified by the environmental conditions and atomic compositions of mineral. By applying the methods, the atomic information of minerals and environmental conditions were successfully inferred in the resultant spectrum.

  18. Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) with Standard Reference Line for the Analysis of Stainless Steel.

    Science.gov (United States)

    Fu, Hongbo; Dong, Fengzhong; Wang, Huadong; Jia, Junwei; Ni, Zhibo

    2017-08-01

    In this work, calibration-free laser-induced breakdown spectroscopy (CF-LIBS) is used to analyze a certified stainless steel sample. Due to self-absorption of the spectral lines from the major element Fe and the sparse lines of trace elements, it is usually not easy to construct the Boltzmann plots of all species. A standard reference line method is proposed here to solve this difficulty under the assumption of local thermodynamic equilibrium so that the same temperature value for all elements present into the plasma can be considered. Based on the concentration and rich spectral lines of Fe, the Stark broadening of Fe(I) 381.584 nm and Saha-Boltzmann plots of this element are used to calculate the electron density and the plasma temperature, respectively. In order to determine the plasma temperature accurately, which is seriously affected by self-absorption, a pre-selection procedure for eliminating those spectral lines with strong self-absorption is employed. Then, one spectral line of each element is selected to calculate its corresponding concentration. The results from the standard reference lines with and without self-absorption of Fe are compared. This method allows us to measure trace element content and effectively avoid the adverse effects due to self-absorption.

  19. LIBS-LIF-Raman: a new tool for the future E-RIHS

    Science.gov (United States)

    Detalle, Vincent; Bai, Xueshi; Bourguignon, Elsa; Menu, Michel; Pallot-Frossard, Isabelle

    2017-07-01

    the creation of new mobile instrumentation, the French institutions are involved in the development of LIBS/LIF/RAMAN portable instrumentation. After a presentation of the challenge and the multiple advantages in building the European Infrastructure and of the French E-RIHS hub, the major interests of associating the three lasers based on analytical methods for a more global and precise characterization of the heritage objects taking into account their precious characters and their specific constraints. Lastly some preliminary results will be presented in order to give a first idea of the power of this analytical tool.

  20. LibQUAL+® and the Information Commons Initiative at Buffalo State College: 2003 to 2009

    Directory of Open Access Journals (Sweden)

    Eugene J. Harvey

    2013-06-01

    Full Text Available Objective – To examine the effect of a transition to an information commons model of service organization on perceptions of library service quality. In 2003, the E. H. Butler Library at Buffalo State College began development of an Information Commons, which included moving the computing help desk to the library, reorganizing the physical units in the library around functional service areas, and moving the reference desk to the lobby.Methods – In 2003, 2006, and 2009, the library administered the LibQUAL+ survey, which measures the relationship between perceived library service delivery and library user satisfaction. The 2003 survey was conducted before the implementation of the Information Commons Initiative. Analyses of variance were conducted to compare the effect of the service changes on users’ perceptions of library service quality between the three data collection points, as well as to explore differences between undergraduate and graduate students. Results – The analyses revealed significant differences between the three data points, with significantly more positive perceptions of library service quality in 2006 and 2009 than in 2003. Comparisons between 2006 and 2009 were not statistically significant. In 2003, no significant differences were found between undergraduate and graduate students’ perceptions. However, in 2006, undergraduate students perceived higher levels of service quality after the development of the Information Commons than graduate students. This difference was maintained in 2009.Conclusion – The Information Commons has become a popular place for new programming, exhibits, workshops, and cultural events on campus. The library staff and administration have regained the respect of the campus community, as well as an appreciation for user-driven input and feedback and for ongoing assessment and evaluation.

  1. 3.76 W of green light generated by intracavity frequency doubling of a 1081.5 nm Yb:GdYSiO2 laser with LiB3O5

    International Nuclear Information System (INIS)

    Zhang, D; Shao, Y; Liu, H P; Li, Y L; Tao, Z H; Ruan, Q R; Zhang, T Y

    2011-01-01

    Efficient continuous-wave (CW) intracavity frequency doubling of a diode-end-pumped Yb:GdYSiO 2 (Yb:GYSO) laser operating on 2 F 5/2 → 2 F 7/2 transitions at 1081.5 nm has been demonstrated. With 17.6 W of diode pump power and the frequency doubling crystal LiB 3 O 5 (LBO), a maximum output power of 3.76 W in the green spectral range at 541 nm has been achieved, corresponding to an optical-to-optical conversion efficiency of 21.4%; the output power stability over 30 min is better than 5%. To the best of our knowledge, this is first work on intracavity frequency doubling of a diode pumped Yb:GYSO laser at 1081.5 nm

  2. A novel er1 allele and the development and validation of its functional marker for breeding pea (Pisum sativum L.) resistance to powdery mildew.

    Science.gov (United States)

    Sun, Suli; Deng, Dong; Wang, Zhongyi; Duan, Canxing; Wu, Xiaofei; Wang, Xiaoming; Zong, Xuxiao; Zhu, Zhendong

    2016-05-01

    A novel er1 allele, er1 -7, conferring pea powdery mildew resistance was characterized by a 10-bp deletion in PsMLO1 cDNA, and its functional marker was developed and validated in pea germplasms. Pea powdery mildew caused by Erysiphe pisi DC is a major disease worldwide. Pea cultivar 'DDR-11' is an elite germplasm resistant to E. pisi. To identify the gene conferring resistance in DDR-11, the susceptible Bawan 6 and resistant DDR-11 cultivars were crossed to produce F1, F2, and F(2:3) populations. The phenotypic segregation patterns in the F2 and F(2:3) populations fit the 3:1 (susceptible:resistant) and 1:2:1 (susceptible homozygotes:heterozygotes:resistant homozygotes) ratios, respectively, indicating that resistance was controlled by a single recessive gene. Analysis of er1-linked markers in the F2 population suggested that the recessive resistance gene in DDR-11 was an er1 allele, which was mapped between markers ScOPE16-1600 and c5DNAmet. To further characterize er1 allele, the cDNA sequences of PsMLO1 from the parents were obtained and a novel er1 allele in DDR-11 was identified and designated as er1-7, which has a 10-bp deletion in position 111-120. The er1-7 allele caused a frame-shift mutation, resulting in a premature termination of translation of PsMLO1 protein. A co-dominant functional marker specific for er1-7 was developed, InDel111-120, which co-segregated with E. pisi resistance in the mapping population. The marker was able to distinguish between pea germplasms with and without the er1-7. Of 161 pea germplasms tested by InDel111-120, seven were detected containing resistance allele er1-7, which was verified by sequencing their PsMLO1 cDNA. Here, a novel er1 allele was characterized and its an ideal functional marker was validated, providing valuable genetic information and a powerful tool for breeding pea resistance to powdery mildew.

  3. Le délibéré aux assises, ultime point aveugle dans l’affaire d’Outreau The deliberation in the Cour d’assises, last blind spot in the Outreau case

    Directory of Open Access Journals (Sweden)

    Jean-Marie Fayol-Noireterre

    2009-02-01

    Full Text Available Cet article envisage les délibérés des cours d’assises, en premier ressort et en appel, de l’affaire d’Outreau, à partir des auditions de la commission d’enquête parlementaire, et à la lumière d’une expérience professionnelle de magistrat (17 années comme juge des enfants, 16 années comme président d'assises. Cette libre projection permet de parcourir, à partir des textes de loi, des pratiques de conduites de délibérés. Il s'agit aussi d'aborder les problèmes inhérents au traitement judiciaire pénal des affaires de mœurs, et leurs spécificités en matière de recherche des preuves de culpabilité, tant en raison de la charge émotionnelle de ces dossiers, que de leur retentissement dans la société française d'aujourd'hui.This article deals with the deliberations in the Cour d’assises in the Outreau case, both in the first resort and in appeal, by using the hearings before the Parliamentary investigation committee and the author’s professional experience as a judge (17 years as children’s judge and 16 years as a President in the Cour d’assises. This free personal reflection gives the opportunity, by using the legal texts, to think over the practices of deliberation. The author also examines the problems inherent to the criminal proceedings in the sex cases and the specificity of evidence of guilt in such cases both because of their emotive power and because of the considerable stir they create in French public opinion nowadays.

  4. Development of master-slave energy management strategy based on fuzzy logic hysteresis state machine and differential power processing compensation for a PEMFC-LIB-SC hybrid tramway

    International Nuclear Information System (INIS)

    Peng, Fei; Zhao, Yuanzhe; Li, Xiaopeng; Liu, Zhixiang; Chen, Weirong; Liu, Yang; Zhou, Donghua

    2017-01-01

    Highlights: •A power system model for the PEMFC based commercial hybrid tramway was established. •An energy management strategy based on master FuHSM and slave DPPC was proposed. •The optimal OER operation of PEMFC subsystem was achieved. •The real-time EMS based HCM optimization was achieved. •The influence on system fuel economy and PEMFC performance degradation was verified. -- Abstract: A hybrid power system configuration based on proton exchange membrane fuel cell (PEMFC), lion-lithium battery (LIB) and supercapacitor (SC) was designed without grid connection for the hybrid tramway. To adapt to the rapid load power change and achieve higher fuel efficiency and optimal oxygen excess ratio (OER) operation of the PEMFC power subsystem, a master-slave energy management strategy based on fuzzy logic hysteresis state machine (FuHSM) and differential power processing compensation (DPPC) was proposed for the hybrid tramway, effectively taking into consideration of the dynamic response and optimum OER tracing of the integrated PEMFC subsystem. The master FuHSM controller was utilized to grantee the optimal power coordination of the multiple power sources and the slave DPPC controller was responsible for further compensating the load power demand to enhance the dynamic performance and bus voltage stability. Furthermore, the equivalent H 2 consumption minimization optimization considering characteristics of the proposed energy management strategy was realized by means of EIA-PSO algorithm to further improve the fuel economy of the overall hybrid power system. The results demonstrate that the proposed energy management strategy can guarantee the stability of the hybrid power system throughout the driving cycle. In addition, more efficient power coordination dynamics among the PEMFC, LIB and SC subsystems could be achieved without additional performance degradation of the integrated PEMFC subsystem, and the results of the comparisons with other control strategies

  5. KARAKTERISASI SPEKTRUM UNSUR Cu UNTUK MENGHITUNG INTENSITAS EMISI ATOM FUNGSI WAKTU TUNDA DENGAN MENGGUNAKAN METODE LASER INDUCED BREAKDOWN SPECTROSCOPY (LIBS

    Directory of Open Access Journals (Sweden)

    Wulansari Efrilinda Diah

    2013-08-01

    Full Text Available Laser-Induced Breakdown Spectroscopy (LIBS is a spectroscopic method is highly reliable for atomic spectrochemical analysis both qualitatively and quantitatively. To achieve this, be aware of the detection parameters, one of which is a function of the atom emission intensity of detection delay time. In this study, plasma is generated by focusing the Nd-YAG laser (1064 nm, 7 ns on the surface of solid Cu sample with 99.99% purity level at 1 atm pressure air environment. Plasma emission spectrometer was arrested by elements of Cu + HR 2500 with specifications: (wavelength range 200-870 nm, resolution 0.1 nm (FWHM, 7 detector CCDs with a combined 14.336 pixels with variation detection delay time 0, 0.5, 1, 1.5, and 2 microseconds after the plasma formation and the energy varies the 60-160mJ. The data showed that the value of the Cu atom emission intensity 521.8 nm of the most highly visible on detection delay time decreased to 0.5 microseconds and detection delay time 2 microseconds. Based on these data it can be concluded that the characterization of the elements Cu to calculate the intensity was in the range of 100-140 mJ laser energy and time delay detection of 0.5 microseconds.

  6. Single-pass, efficient type-I phase-matched frequency doubling of high-power ultrashort-pulse Yb-fiber laser using LiB_3O_5

    Science.gov (United States)

    Shukla, Mukesh Kumar; Kumar, Samir; Das, Ritwick

    2016-05-01

    We report 48 % efficient single-pass second harmonic generation of high-power ultrashort-pulse ({≈ }250 fs) Yb-fiber laser by utilizing type-I phase matching in LiB_3O_5 (LBO) crystal. The choice of LBO among other borate crystals for high-power frequency doubling is essentially motivated by large thermal conductivity, low birefringence and weak group velocity dispersion. By optimally focussing the beam in a 4-mm-long LBO crystal, we have generated about 2.3 W of average power at 532 nm using 4.8 W of available pump power at 1064 nm. The ultrashort green pulses were found out to be near-transform limited sech^2 pulses with a pulse width of Δ τ ≈ 150 fs and being delivered at 78 MHz repetition rate. Due to appreciably low spatial walk-off angle for LBO ({≈ }0.4°), we obtain M^2beam which signifies marginal distortion in comparison with the pump beam (M^2<1.15). We also discuss the impact of third-order optical nonlinearity of the LBO crystal on the generated ultrashort SH pulses.

  7. Dual-Spectroscopy Platform for the Surveillance of Mars Mineralogy Using a Decisions Fusion Architecture on Simultaneous LIBS-Raman Data.

    Science.gov (United States)

    Moros, Javier; ElFaham, Mohamed Mostafa; Laserna, J Javier

    2018-02-06

    A single platform, integrated by a laser-induced breakdown spectroscopy detector and a Raman spectroscopy sensor, has been designed to remotely (5 m) and simultaneously register the elemental and molecular signatures of rocks under Martian surface conditions. From this information, new data fusion architecture at decisions level is proposed for the correct categorization of the rocks. The approach is based on a decision-making process from the sequential checking of the spectral features representing the cationic and anionic counterparts of the specimen. The scrutiny of the LIBS response by using a moving-window algorithm informs on the diversity of the elemental constituents. The output rate of emission lines allows projecting in a loop the elements as the cationic counterpart of the rock. In parallel, the Raman response of the unknown is compared with all the molecular counterparts of the hypothesized cation that are stored in a spectral library. The largest similarity rate unveils the final identity of the unknown. The identification capabilities of the architecture have been underscored through blind tests of 10 natural rocks with different origins. The great majority of forecasts have matched with the real identities of the inspected targets. The strength of this platform to simultaneously acquire the multielemental and the molecular information from a specimen by using the same laser events greatly enhances the "on-surface" missions for the surveillance of mineralogy.

  8. Qualitative tissue differentiation by analysing the intensity ratios of atomic emission lines using laser induced breakdown spectroscopy (LIBS): prospects for a feedback mechanism for surgical laser systems.

    Science.gov (United States)

    Kanawade, Rajesh; Mahari, Fanuel; Klämpfl, Florian; Rohde, Maximilian; Knipfer, Christian; Tangermann-Gerk, Katja; Adler, Werner; Schmidt, Michael; Stelzle, Florian

    2015-01-01

    The research work presented in this paper focuses on qualitative tissue differentiation by monitoring the intensity ratios of atomic emissions using 'Laser Induced Breakdown Spectroscopy' (LIBS) on the plasma plume created during laser tissue ablation. The background of this study is to establish a real time feedback control mechanism for clinical laser surgery systems during the laser ablation process. Ex-vivo domestic pig tissue samples (muscle, fat, nerve and skin) were used in this experiment. Atomic emission intensity ratios were analyzed to find a characteristic spectral line for each tissue. The results showed characteristic elemental emission intensity ratios for the respective tissues. The spectral lines and intensity ratios of these specific elements varied among the different tissue types. The main goal of this study is to qualitatively and precisely identify different tissue types for tissue specific laser surgery. © 2015 The Authors. Journal of Biophotonics published by WILEY-VCH Verlag.

  9. Soybean diseases in Poland

    Directory of Open Access Journals (Sweden)

    J. Marcinkowska

    2013-12-01

    Full Text Available Field observations on the occurrence of soybean diseases were undertaken in the southern and central regions of Poland in the period 1976-1980. Most prevalent were foliage diseases caused by Peronospora manshurica, Pseudomonas syrinqae pv. glycinea and soybean mosaic virus (SMV. Sclerotinia sclerotiorum and Ascochyta sojaecola were reported as pathogens of local importance. The following pathogenic fungi: Botrytis cinerea, Fusarium culmorum, F. oxysporum and Rhizoctonia solani were also isolated from soybean.

  10. SOJA L’économie du soja en Chine : les défis liés à la libéralisation

    Directory of Open Access Journals (Sweden)

    Aubert Claude

    2001-05-01

    Full Text Available Longtemps principal producteur et exportateur de soja, la Chine a perdu sa position de leader mondial au bénéfice des États-Unis dans les années 50. Bien que ce grain n’ait pas été concerné par la Révolution Verte comme le riz, le maïs ou le blé, la production de soja a doublé en Chine au cours du dernier quart de siècle. Pourtant les besoins du pays - notamment pour l’alimentation animale - progressent plus vite que la production de soja : la Chine est devenue importatrice nette de graine, de tourteau et d’huile au milieu des années 90. À l’intérieur de son territoire, les systèmes de production diffèrent selon les régions et la superficie emblavée en soja varie beaucoup en fonction de son prix relatif avec le maïs. Suite à la désétatisation de cette filière dans le pays et à la libéralisation du commerce extérieur, on assiste actuellement à une modernisation de l’industrie de trituration dont les effets en termes de compétitivité pourraient se faire sentir dans les autres pays producteurs.

  11. Selection of endophytic fungi from comfrey (Symphytum officinale L.) for in vitro biological control of the phytopathogen Sclerotinia sclerotiorum (Lib.).

    Science.gov (United States)

    Rocha, Rafaeli; da Luz, Daniela Eleutério; Engels, Cibelle; Pileggi, Sônia Alvim Veiga; de Souza Jaccoud Filho, David; Matiello, Rodrigo Rodrigues; Pileggi, Marcos

    2009-01-01

    Biological control consists of using one organism to attack another that may cause economic damage to crops. Integrated Pest Management (IPM) is a very common strategy. The white mold produced by Sclerotinia sclerotiorum (Lib.) causes considerable damage to bean crops. This fungus is a soil inhabitant, the symptoms of which are characterized by water-soaked lesions covered by a white cottony fungal growth on the soil surface and/or the host plant. Possible biological control agents taken from plants are being investigated as phytopathogen inhibitors. These are endophytic microorganisms that inhabit the intercellular spaces of vegetal tissues and are often responsible for antimicrobial production. The objective of the present study was to select endophytic fungi isolated from comfrey (Symphytum officinale L.) leaves with in vitro antagonist potential against the phytopathogenic fungus S. sclerotiorum. Twelve isolates of endophytic fungi and a pathogenic strain of S. sclerotiorum were used in the challenge method. With the aid of this method, four endophytes with the best antagonistic activity against S. sclerotiorum were selected. Pathogen growth inhibition zones were considered indicative of antibiosis. The percentages of pathogenic mycelia growth were measured both with and without the antagonist, resulting in growth reductions of 46.7% to 50.0% for S. sclerotiorum. These analyses were performed by evaluating the endophytic/pathogenic mycelia growth in mm/day over an eight-day period of antagonistic tests.

  12. Effect of epidermal growth factor (EGF) on [3H]TdR incorporation into DNA in ad lib fed and fasted CD2F1 mice

    International Nuclear Information System (INIS)

    Scheving, L.A.; Tsai, T.H.; Scheving, L.E.; Hoke, W.S.

    1987-01-01

    The effect of EGF on the incorporation of [ 3 H]TdR into DNA (DNA synthesis) was determined in the esophagus, liver, pancreas, and kidney in mice standardized to 12 hours (hr) of light alternating with 12 hr of darkness. A question asked was whether intraperitoneally administered EGF could alter the circadian patterns of DNA synthesis in these organs. The most marked effects of EGF were: an increase in DNA synthesis but only after a specific duration of time after treatment, ranging from 8 to 23 hr, which differed for each tissue, a similarity in the response of the esophagus in both ad lib fed and fasted mice, but not in the response of the liver, where the stimulatory effect of EGF observed in fed mice was dramatically reduced in fasted ones, and an advance in the phasing of the circadian rhythm in DNA synthesis of the esophagus by about 12 hr. In addition, no sex differences in fasted animals were found under the conditions of this study

  13. Beech cupules share endophytic fungi with leaves and twigs

    OpenAIRE

    Tateno, Osamu; Hirose, Dai; Osono, Takashi; Takeda, Hiroshi

    2015-01-01

    Endophytic mycobiota on leaves, twigs and cupules of Fagus crenata were investigated using a culture-dependent method over a growing season to test the hypothesis that endophytic fungi of cupule (a woody phyllome) share some components of the endophytic fungal assemblages with both leaves and twigs. A total of 14 fungal taxa were isolated, and the most frequent taxon was Phomopsis sp., followed by Xylaria sp., Ascochyta fagi and Geniculosporium sp. The compositions of fungal assemblages of le...

  14. Production of heterologous cutinases by E. coli and improved enzyme formulation for application on plastic degradation

    OpenAIRE

    Gomes,Daniela S; Matamá,Teresa; Cavaco-Paulo,Artur; Campos-Takaki,Galba M; Salgueiro,Alexandra A

    2013-01-01

    Background: The hydrolytic action of cutinases has been applied to the degradation of plastics. Polyethylene terephthalate (PET) have long half-life which constitutes a major problem for their treatment as urban solid residues. The aim of this work was to characterize and to improve stable the enzyme to optimize the process of degradation using enzymatic hydrolysis of PET by recombinant cutinases. Results: The wild type form of cutinase from Fusarium solani pisi and its C-terminal fusion to c...

  15. Impact of Genomic Technologies on Chickpea Breeding Strategies

    Directory of Open Access Journals (Sweden)

    Rajeev K. Varshney

    2012-08-01

    Full Text Available The major abiotic and biotic stresses that adversely affect yield of chickpea (Cicer arietinum L. include drought, heat, fusarium wilt, ascochyta blight and pod borer. Excellent progress has been made in developing short-duration varieties with high resistance to fusarium wilt. The early maturity helps in escaping terminal drought and heat stresses and the adaptation of chickpea to short-season environments. Ascochyta blight continues to be a major challenge to chickpea productivity in areas where chickpea is exposed to cool and wet conditions. Limited variability for pod borer resistance has been a major bottleneck in the development of pod borer resistant cultivars. The use of genomics technologies in chickpea breeding programs has been limited, since available genomic resources were not adequate and limited polymorphism was observed in the cultivated chickpea for the available molecular markers. Remarkable progress has been made in the development of genetic and genomic resources in recent years and integration of genomic technologies in chickpea breeding has now started. Marker-assisted breeding is currently being used for improving drought tolerance and combining resistance to diseases. The integration of genomic technologies is expected to improve the precision and efficiency of chickpea breeding in the development of improved cultivars with enhanced resistance to abiotic and biotic stresses, better adaptation to existing and evolving agro-ecologies and traits preferred by farmers, industries and consumers.

  16. Three-Dimensional Modeling of the Thermal Behavior of a Lithium-Ion Battery Module for Hybrid Electric Vehicle Applications

    Directory of Open Access Journals (Sweden)

    Jaeshin Yi

    2014-11-01

    Full Text Available This paper reports a modeling methodology to predict the effects of operating conditions on the thermal behavior of a lithium-ion battery (LIB module. The potential and current density distributions on the electrodes of an LIB cell are predicted as a function of discharge time based on the principle of charge conservation. By using the modeling results of the potential and current density distributions of the LIB cell, the non-uniform distribution of the heat generation rate in a single LIB cell within the module is calculated. Based on the heat generation rate in the single LIB cell determined as a function of the position on the electrode and time, a three-dimensional thermal modeling of an LIB module is performed to calculate the three-dimensional velocity, pressure, and temperature distributions within the LIB module as a function of time at various operating conditions. Thermal modeling of an LIB module is validated by the comparison between the experimental measurements and the modeling results. The effect of the cooling condition of the LIB module on the temperature rise of the LIB cells within the module and the uniformity of the distribution of the cell temperatures are analyzed quantitatively based on the modeling results.

  17. Automotive Lithium-ion Cell Manufacturing: Regional Cost Structures and Supply Chain Considerations

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Donald [Clean Energy Manufacturing Analysis Center, Godlen, CO (United States); Elgqvist, Emma [Clean Energy Manufacturing Analysis Center, Godlen, CO (United States); Santhanagopalan, Shriram [Clean Energy Manufacturing Analysis Center, Godlen, CO (United States)

    2016-04-08

    Manufacturing capacity for lithium-ion batteries (LIBs)--which power many consumer electronics and are increasingly used to power electric vehicles--is heavily concentrated in east Asia. Currently, China, Japan, and Korea collectively host 88% of all LIB cell and 79% of automotive LIB cell manufacturing capacity. Mature supply chains and strong cumulative production experience suggest that most LIB cell production will remain concentrated in Asia. However, other regions--including North America--could be competitive in the growing automotive LIB cell market under certain conditions. To illuminate the factors that drive regional competitiveness in automotive LIB cell production, this study models cell manufacturing cost and minimum sustainable price, and examines development of LIB supply chains and current LIB market conditions. Modeled costs are for large format, 20-Ah stacked pouch cells with lithium-nickel-manganese-cobalt-oxide (NMC) cathodes and graphite anodes suitable for automotive application. Production volume is assumed to be at commercial scale, 600 MWh per year.

  18. Laser ablation-laser induced breakdown spectroscopy for the measurement of total elemental concentration in soils.

    Science.gov (United States)

    Pareja, Jhon; López, Sebastian; Jaramillo, Daniel; Hahn, David W; Molina, Alejandro

    2013-04-10

    The performances of traditional laser-induced breakdown spectroscopy (LIBS) and laser ablation-LIBS (LA-LIBS) were compared by quantifying the total elemental concentration of potassium in highly heterogeneous solid samples, namely soils. Calibration curves for a set of fifteen samples with a wide range of potassium concentrations were generated. The LA-LIBS approach produced a superior linear response different than the traditional LIBS scheme. The analytical response of LA-LIBS was tested with a large set of different soil samples for the quantification of the total concentration of Fe, Mn, Mg, Ca, Na, and K. Results showed an acceptable linear response for Ca, Fe, Mg, and K while poor signal responses were found for Na and Mn. Signs of remaining matrix effects for the LA-LIBS approach in the case of soil analysis were found and discussed. Finally, some improvements and possibilities for future studies toward quantitative soil analysis with the LA-LIBS technique are suggested.

  19. 1945, Le jazz libère l’Allemagne... pour la seconde fois

    Directory of Open Access Journals (Sweden)

    Pascale Cohen-Avenel

    2010-11-01

    Full Text Available 1945, l’Allemagne vaincue est détruite, le régime en déroute, les morts innombrables, un grand nombre d’hommes faits prisonniers. La démocratie n’existe pas. Tout est à (reconstruire. Arrivent alors les troupes alliées et, avec les Américains, le jazz, une musique si prenante que bon nombre de jeunes d’Europe se laissent séduire immédiatement. Comme d’autres européens, les Allemands sont saisis par cette musique qui leur permet de se libérer, de s’exprimer et de le faire à l’unisson des autres États, vaincus ou vainqueurs. C’est au son de cette musique américaine, et plus tard du rock ‘n’ roll, qu’ils vont apprendre ou réapprendre la démocratie occidentale. Mais le triomphe de cette musique est-il seulement émancipateur ? N’est-il pas aussi le signe d’une domination du monde, nouvelle et sans partage, par le géant américain et sa puissance économique dont le plan Marshall incarne à la fois les bienfaits et la toute-puissance ? En fait, cette question est loin d’être inédite en Allemagne. Elle s’est déjà posée avec la même acuité en 1920, date à laquelle les Allemands furent confrontés pour la première fois au jazz dans des circonstances assez proches : une défaite humiliante, l’effondrement du régime, une démocratie imposée par les vainqueurs, la quête d’une culture et de valeurs démocratiques sans racines dans l’inconscient collectif, une possible émancipation des corps grâce à la danse après des années d’oppression et de militarisme. Car c’est dès 1920 que les Allemands découvrent le jazz, une musique alors non seulement américaine, mais noire, une musique qui semble primitive, mais qui incarne aussi les grandes villes les plus modernes du monde et une domination économique que les Allemands craignent depuis la fin du XXe siècle. D’économique, le « péril américain », se fait culturel par le biais de la danse. A moins qu’il n’offre enfin aux

  20. IMPLEMENTACIÓN DE TÉCNICAS ESPECTROQUÍMICAS EN LA INVESTIGACIÓN ZOOARQUEOLÓGICA. CUANTIFICACIÓN DE ESTRONCIO UTILIZANDO LASER INDUCED BREAKDOWN SPECTROSCOPY (LIBS/ Implementation of spectrochemical techniques in zooarchaeological research...

    Directory of Open Access Journals (Sweden)

    Gabriela Srur

    2012-11-01

    Full Text Available Los estudios químicos sobre restos zooarqueológicos se vienen desarrollando con mayor intensidad en las últimas décadas, especialmente aquellos dedicados a la identificación de huellas químicas o diversos tipos de isótopos y sus relaciones. El objetivo de este trabajo es el de presentar dos procedimientos utilizados para la caracterización química de huesos en base a datos espectrométricos obtenidos mediante la técnica LIBS (Laser Induced Breakdown Spectroscopy. El primero denominado Adición Estándar, consiste en un procedimiento destructivo, con un grado de error estimable, mientras que el segundo, Reemplazo de la Matriz Ósea, constituye un método no invasivo y con un grado de error relativamente bajo. Con esto se espera lograr el desarrollo de un corpus metodológico y analítico que permita caracterizar de un modo eficiente y económico las huellas químicas de diverso material arqueofaunístico. En este sentido se intenta lograr una caracterización química de huesos arqueológicos con el fin de dar respuesta a cuestiones relacionadas tanto a la alimentación como a la movilidad de los animales en el pasado. Abstract Chemical studies on zooarchaeological remains have been most extensively developed in recent decades, especially those focused on the identification of chemical fingerprints or types of isotopes and their relationships. This paper aims at showing two procedures used for chemical characterization of bones on the basis of spectrometric data obtained by LIBS technique (Laser Induced Breakdown Spectroscopy. One called Standard Addition, a destructive procedure, with a high error degree; the other called Bone Matrix Replacement, a noninvasive method with a relatively low error degree. We expect to gather a methodological and analytical corpus to characterize, efficiently and inexpensively, the chemical fingerprints of diverse archaeofaunal material. Hence, we intend to achieve chemical characterization of

  1. A review on management of spent lithium ion batteries and strategy for resource recycling of all components from them.

    Science.gov (United States)

    Zhang, Wenxuan; Xu, Chengjian; He, Wenzhi; Li, Guangming; Huang, Juwen

    2018-02-01

    The wide use of lithium ion batteries (LIBs) has brought great numbers of discarded LIBs, which has become a common problem facing the world. In view of the deleterious effects of spent LIBs on the environment and the contained valuable materials that can be reused, much effort in many countries has been made to manage waste LIBs, and many technologies have been developed to recycle waste LIBs and eliminate environmental risks. As a review article, this paper introduces the situation of waste LIB management in some developed countries and in China, and reviews separation technologies of electrode components and refining technologies of LiCoO 2 and graphite. Based on the analysis of these recycling technologies and the structure and components characteristics of the whole LIB, this paper presents a recycling strategy for all components from obsolete LIBs, including discharge, dismantling, and classification, separation of electrode components and refining of LiCoO 2 /graphite. This paper is intended to provide a valuable reference for the management, scientific research, and industrial implementation on spent LIBs recycling, to recycle all valuable components and reduce the environmental pollution, so as to realize the win-win situation of economic and environmental benefits.

  2. The Role of Sub- and Supercritical CO2 as "Processing Solvent" for the Recycling and Sample Preparation of Lithium Ion Battery Electrolytes.

    Science.gov (United States)

    Nowak, Sascha; Winter, Martin

    2017-03-06

    Quantitative electrolyte extraction from lithium ion batteries (LIB) is of great interest for recycling processes. Following the generally valid EU legal guidelines for the recycling of batteries, 50 wt % of a LIB cell has to be recovered, which cannot be achieved without the electrolyte; hence, the electrolyte represents a target component for the recycling of LIBs. Additionally, fluoride or fluorinated compounds, as inevitably present in LIB electrolytes, can hamper or even damage recycling processes in industry and have to be removed from the solid LIB parts, as well. Finally, extraction is a necessary tool for LIB electrolyte aging analysis as well as for post-mortem investigations in general, because a qualitative overview can already be achieved after a few minutes of extraction for well-aged, apparently "dry" LIB cells, where the electrolyte is deeply penetrated or even gellified in the solid battery materials.

  3. Enhancement and stabilization of plasma using collinear long-short double-pulse laser-induced breakdown spectroscopy

    Science.gov (United States)

    Cui, Minchao; Deguchi, Yoshihiro; Wang, Zhenzhen; Fujita, Yuki; Liu, Renwei; Shiou, Fang-Jung; Zhao, Shengdun

    2018-04-01

    A collinear long-short dual-pulse laser-induced breakdown spectroscopy (DP-LIBS) method was employed to enhance and stabilize the laser-induced plasma from steel sample. The long-pulse-width laser beam with the pulse width of 60 μs was generated by a Nd: YAG laser which was operated at FR (free running) mode. The comparative experiments were carried out between single pulse LIBS (SP-LIBS) and long-short DP-LIBS. The recorded results showed that the emission intensities and the temperature of plasma were enhanced by long-short DP-LIBS. The plasma images showed that the plasma was bigger and had a longer lifetime in long-short DP-LIBS situation. Through the calculation of time-resolved plasma temperature and intensity ratio, it can be concluded that the plasma was stabilized by the long-pulse-width laser beam. The long-short DP-LIBS method also generated the stable plasma condition from the samples with different initial temperatures, which overcame the difficulties of LIBS in the online measurement for steel production line.

  4. Selection of endophytic fungi from comfrey (Symphytum officinale L. for in vitro biological control of the phytopathogen Sclerotinia sclerotiorum (Lib. Seleção de fungos endofíticos de confrei (Symphytum officinale L., buscando controle biológico in vitro do fitopatógeno Sclerotinia sclerotiorum (Lib.

    Directory of Open Access Journals (Sweden)

    Rafaeli Rocha

    2009-03-01

    Full Text Available Biological control consists of using one organism to attack another that may cause economic damage to crops. Integrated Pest Management (IPM is a very common strategy. The white mold produced by Sclerotiniasclerotiorum (Lib. causes considerable damage to bean crops. This fungus is a soil inhabitant, the symptoms of which are characterized by water-soaked lesions covered by a white cottony fungal growth on the soil surface and/or the host plant. Possible biological control agents taken from plants are being investigated as phytopathogen inhibitors. These are endophytic microorganisms that inhabit the intercellular spaces of vegetal tissues and are often responsible for antimicrobial production. The objective of the present study was to select endophytic fungi isolated from comfrey (Symphytumofficinale L. leaves with in vitro antagonist potential against the phytopathogenic fungus S. sclerotiorum. Twelve isolates of endophytic fungi and a pathogenic strain of S. sclerotiorum were used in the challenge method. With the aid of this method, four endophytes with the best antagonistic activity against S. sclerotiorum were selected. Pathogen growth inhibition zones were considered indicative of antibiosis. The percentages of pathogenic mycelia growth were measured both with and without the antagonist, resulting in growth reductions of 46.7% to 50.0% for S. sclerotiorum. These analyses were performed by evaluating the endophytic/pathogenic mycelia growth in mm/day over an eight-day period of antagonistic tests.O controle biológico consiste no uso de organismos que atacam outros que causam danos a culturas de plantas. Esta é uma estratégia muito utilizada no Controle Integrado de Pragas (CIP. O mofo branco, causado por Sclerotiniasclerotiorum (Lib., causa danos em culturas de feijão. Este fungo é encontrado no solo e seus sintomas são caracterizados por lesões úmidas cobertas por micélios algodonosos, crescidos a partir do solo e/ou da planta

  5. A review of the development of portable laser induced breakdown spectroscopy and its applications

    Energy Technology Data Exchange (ETDEWEB)

    Rakovský, J., E-mail: jozef.rakovsky@jh-inst.cas.cz [J. Heyrovský Institute of Physical Chemistry, Academy of Sciences of the Czech Republic, Dolejškova 3, 18223 Prague 8 (Czech Republic); Čermák, P. [Department of Experimental Physics, Faculty of Mathematics, Physics and Informatics, Comenius University, Mlynská dolina F2, 842 48 Bratislava (Slovakia); Musset, O. [Laboratoire interdisciplinaire Carnot de Bourgogne, UMR CNRS 6303, Université de Bourgogne, BP 47 870, F-21078 Dijon Cedex (France); Veis, P. [Department of Experimental Physics, Faculty of Mathematics, Physics and Informatics, Comenius University, Mlynská dolina F2, 842 48 Bratislava (Slovakia)

    2014-11-01

    In this review, we present person-transportable laser induced breakdown spectroscopy (LIBS) devices that have previously been developed and reported in the literature as well as their applications. They are compared with X-ray fluorescent (XRF) devices, which represent their strongest competition. Although LIBS devices have advantages over XRF devices, such as sensitivity to the light elements, high spatial resolution and the possibility to distinguish between different layers of the sample, there are also disadvantages and both are discussed here. Furthermore, the essential portable LIBS instrumentation (laser, spectrograph and detector) is presented, and published results related to new laser sources (diode-pumped solid-state, microchip and fiber lasers) used in LIBS are overviewed. Compared to conventional compact flashlamp pumped solid-state lasers, the new laser sources provide higher repetition rates, higher efficiency (less power consumption) and higher beam quality, resulting in higher fluences, even for lower energies, and could potentially increase the figure of merit of portable LIBS instruments. Compact spectrometers used in portable LIBS devices and their parts (spectrograph, detector) are also discussed. - Highlights: • Overview of portable LIBS devices transportable by a person • Discussion and new trends about portable LIBS instrumentation: laser, spectrograph and detector • Overview of applications of DPSS, microchip and fiber lasers in LIBS.

  6. The Role of Sub- and Supercritical CO2 as “Processing Solvent” for the Recycling and Sample Preparation of Lithium Ion Battery Electrolytes

    Directory of Open Access Journals (Sweden)

    Sascha Nowak

    2017-03-01

    Full Text Available Quantitative electrolyte extraction from lithium ion batteries (LIB is of great interest for recycling processes. Following the generally valid EU legal guidelines for the recycling of batteries, 50 wt % of a LIB cell has to be recovered, which cannot be achieved without the electrolyte; hence, the electrolyte represents a target component for the recycling of LIBs. Additionally, fluoride or fluorinated compounds, as inevitably present in LIB electrolytes, can hamper or even damage recycling processes in industry and have to be removed from the solid LIB parts, as well. Finally, extraction is a necessary tool for LIB electrolyte aging analysis as well as for post-mortem investigations in general, because a qualitative overview can already be achieved after a few minutes of extraction for well-aged, apparently “dry” LIB cells, where the electrolyte is deeply penetrated or even gellified in the solid battery materials.

  7. Inclusion Detection in Aluminum Alloys Via Laser-Induced Breakdown Spectroscopy

    Science.gov (United States)

    Hudson, Shaymus W.; Craparo, Joseph; De Saro, Robert; Apelian, Diran

    2018-04-01

    Laser-induced breakdown spectroscopy (LIBS) has shown promise as a technique to quickly determine molten metal chemistry in real time. Because of its characteristics, LIBS could also be used as a technique to sense for unwanted inclusions and impurities. Simulated Al2O3 inclusions were added to molten aluminum via a metal-matrix composite. LIBS was performed in situ to determine whether particles could be detected. Outlier analysis on oxygen signal was performed on LIBS data and compared to oxide volume fraction measured through metallography. It was determined that LIBS could differentiate between melts with different amounts of inclusions by monitoring the fluctuations in signal for elements of interest. LIBS shows promise as an enabling tool for monitoring metal cleanliness.

  8. Analyse et évaluation de l’argumentation dans l’analyse critique du discours (CDA : délibération et dialectique des Lumières Analysis and Evaluation of Argumentation in Critical Discourse Analysis: Deliberation and the Dialectic of Enlightenment

    Directory of Open Access Journals (Sweden)

    Norman Fairclough

    2012-10-01

    Full Text Available Cet article représente le développement de notre récent travail sur le discours politique, centré sur les réactions politiques à l’actuelle crise financière et économique en Grande-Bretagne. Considérant le discours politique comme doté d’un caractère essentiellement argumentatif, et plus spécifiquement comme une forme d’argumentation et de délibération pratiques, nous soutenons qu’une analyse critique de ce discours appelle à intégrer la théorie et l’analyse de l’argumentation à la version de l’analyse critique du discours (CDA avec laquelle nous travaillons. La présentation de cette version de la CDA, et de notre approche de l’analyse et de l’évaluation de l’argumentation et de la délibération pratiques, est suivie d’une illustration de la démarche. Celle-ci se réfère à une partie du discours sur le Budget prononcé en juin 2010 par Georges Osborne, Chancelier de l’Echiquier du gouvernement britannique de coalition entre conservateurs et libéraux démocrates, et à la mise en cause critique de la stratégie d’austérité du gouvernement qui eu lieu dans le débat public, particulièrement dans les média. Dans la dernière partie de cet article, nous avançons que notre approche innovatrice de l’analyse et de l’évaluation de l’argumentation et de la délibération pratiques contribue de manière particulièrement efficace à promouvoir l’objectif de la CDA : étendre au discours les formes de critique répandues dans le champ de la théorie sociale critique. Nous nous appuyons pour ce faire sur les débats qui traitent des rapports entre critique et rationalité. Nous posons que l’approche normative que nous adoptons est nécessaire pour intégrer l’analyse du discours argumentatif à la critique, et que notre démarche est en parfait accord avec les objectifs de la théorie critique, du moins tels que Habermas les conçoit.This paper is a development of our recent work on

  9. A Simple Prelithiation Strategy To Build a High-Rate and Long-Life Lithium-Ion Battery with Improved Low-Temperature Performance.

    Science.gov (United States)

    Liu, Yao; Yang, Bingchang; Dong, Xiaoli; Wang, Yonggang; Xia, Yongyao

    2017-12-22

    Lithium-ion batteries (LIBs) are being used to power the commercial electric vehicles (EVs). However, the charge/discharge rate and life of current LIBs still cannot satisfy the further development of EVs. Furthermore, the poor low-temperature performance of LIBs limits their application in cold climates and high altitude areas. Herein, a simple prelithiation method is developed to fabricate a new LIB. In this strategy, a Li 3 V 2 (PO 4 ) 3 cathode and a pristine hard carbon anode are used to form a primary cell, and the initial Li + extraction from Li 3 V 2 (PO 4 ) 3 is used to prelithiate the hard carbon. Then, the self-formed Li 2 V 2 (PO 4 ) 3 cathode and prelithiated hard carbon anode are used to form a 4 V LIB. The LIB exhibits a maximum energy density of 208.3 Wh kg -1 , a maximum power density of 8291 W kg -1 and a long life of 2000 cycles. When operated at -40 °C, the LIB can keep 67 % capacity of room temperature, which is much better than conventional LIBs. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Combining Raman and laser induced breakdown spectroscopy by double pulse lasing.

    Science.gov (United States)

    Lednev, Vasily N; Pershin, Sergey M; Sdvizhenskii, Pavel A; Grishin, Mikhail Ya; Fedorov, Alexander N; Bukin, Vladimir V; Oshurko, Vadim B; Shchegolikhin, Alexander N

    2018-01-01

    A new approach combining Raman spectrometry and laser induced breakdown spectrometry (LIBS) within a single laser event was suggested. A pulsed solid state Nd:YAG laser running in double pulse mode (two frequency-doubled sequential nanosecond laser pulses with dozens microseconds delay) was used to combine two spectrometry methods within a single instrument (Raman/LIBS spectrometer). First, a low-energy laser pulse (power density far below ablation threshold) was used for Raman measurements while a second powerful laser pulse created the plasma suitable for LIBS analysis. A short time delay between two successive pulses allows measuring LIBS and Raman spectra at different moments but within a single laser flash-lamp pumping. Principal advantages of the developed instrument include high quality Raman/LIBS spectra acquisition (due to optimal gating for Raman/LIBS independently) and absence of target thermal alteration during Raman measurements. A series of high quality Raman and LIBS spectra were acquired for inorganic salts (gypsum, anhydrite) as well as for pharmaceutical samples (acetylsalicylic acid). To the best of our knowledge, the quantitative analysis feasibility by combined Raman/LIBS instrument was demonstrated for the first time by calibration curves construction for acetylsalicylic acid (Raman) and copper (LIBS) in gypsum matrix. Combining ablation pulses and Raman measurements (LIBS/Raman measurements) within a single instrument makes it an efficient tool for identification of samples hidden by non-transparent covering or performing depth profiling analysis including remote sensing. Graphical abstract Combining Raman and laser induced breakdown spectroscopy by double pulse lasing.

  11. Influência do zinco na incidência de doenças do cafeeiro Zinc influence on coffee diseases

    Directory of Open Access Journals (Sweden)

    Vicente Luiz de Carvalho

    2008-06-01

    Full Text Available Em cafeeiros, poucos estudos foram feitos relacionando aumento ou diminuição da resistência das plantas às doenças, com alteração dos níveis de nutrientes utilizados. Com este trabalho, objetivou-se estudar os efeitos do sulfato de zinco aplicado isoladamente, e associado com fungicidas e cloreto de potássio sobre a ferrugem, cercosporiose e manchas foliares do cafeeiro. O trabalho foi desenvolvido em uma lavoura de café em produção, onde foram testados oxicloreto de cobre, tebuconazole, sulfato de zinco + cloreto de potássio e sulfato de zinco e nas subparcelas foram realizadas diferentes concentrações de sulfato de zinco: ausência, 0,3 %, 0,6 % e 1,2 %. Verificou-se que os tratamentos com oxicloreto de cobre e tebuconazole reduziram a incidência e severidade de ferrugem, a incidência de cercosporiose, de manchas foliares (phoma e ascochyta e a desfolha, independente das concentrações de sulfato de zinco utilizadas. Concentrações de sulfato de zinco na faixa de 0,6 % - 0,75 % apresentaram menor severidade da ferrugem e o aumento nas concentrações de sulfato de zinco aumentou a incidência de cercosporiose, manchas foliares e a desfolha dos cafeeiros.The are few studies have been done related to the increase or decrease of disease resistance in coffee plants, with alteration from plant nutrient levels. The ain of this work was to verify the effect of zinc sulfate, applied either alone or in association with fungicides, and the effect of potassium chloride on coffee leaf rust, brown-eyes and leaf stains in coffee plants. Copper oxichloride, tebuconazole, sulfate of zinc + potassium chloride and sulfate of zinc were applied on plots and concentrations of zinc sulfate (0,0 %, 0,3 %, 0,6 % and 1,2 % were applied on sub plot. Treatments with copper and tebuconazole reduced the incidence and severity of rust, the incidence of brown-eyes and stains leaf (phoma and ascochyta and the defoliate independent of the zinc sulfate

  12. Signal enhancement in collinear double-pulse laser-induced breakdown spectroscopy applied to different soils

    Energy Technology Data Exchange (ETDEWEB)

    Nicolodelli, Gustavo, E-mail: gunicolodelli@hotmail.com [Embrapa Instrumentation, Rua XV de Novembro, 1452, CEP 13560-970 São Carlos, SP (Brazil); Senesi, Giorgio Saverio, E-mail: giorgio.senesi@imip.cnr.it [Institute of Inorganic Methodologies and Plasmas, CNR, Bari, 70126 Bari (Italy); Romano, Renan Arnon, E-mail: renan.romano@gmail.com [Embrapa Instrumentation, Rua XV de Novembro, 1452, CEP 13560-970 São Carlos, SP (Brazil); Physics Institute of São Carlos, University of São Paulo, IFSC-USP, Av. Trabalhador são-carlense, 400 Pq. Arnold Schimid, 13566-590 São Carlos, SP (Brazil); Oliveira Perazzoli, Ivan Luiz de, E-mail: ivanperazzoli@hotmail.com [Embrapa Instrumentation, Rua XV de Novembro, 1452, CEP 13560-970 São Carlos, SP (Brazil); Milori, Débora Marcondes Bastos Pereira, E-mail: debora.milori@embrapa.br [Embrapa Instrumentation, Rua XV de Novembro, 1452, CEP 13560-970 São Carlos, SP (Brazil)

    2015-09-01

    Laser-induced breakdown spectroscopy (LIBS) is a well-known consolidated analytical technique employed successfully for the qualitative and quantitative analysis of solid, liquid, gaseous and aerosol samples of very different nature and origin. Several techniques, such as dual-pulse excitation setup, have been used in order to improve LIBS's sensitivity. The purpose of this paper was to optimize the key parameters as excitation wavelength, delay time and interpulse, that influence the double pulse (DP) LIBS technique in the collinear beam geometry when applied to the analysis at atmospheric air pressure of soil samples of different origin and texture from extreme regions of Brazil. Additionally, a comparative study between conventional single pulse (SP) LIBS and DP LIBS was performed. An optimization of DP LIBS system, choosing the correct delay time between the two pulses, was performed allowing its use for different soil types and the use of different emission lines. In general, the collinear DP LIBS system improved the analytical performances of the technique by enhancing the intensity of emission lines of some elements up to about 5 times, when compared with conventional SP-LIBS, and reduced the continuum emission. Further, the IR laser provided the best performance in re-heating the plasma. - Highlights: • The correct choice of the delay time between the two pulses is crucial for the DP system. • An optimization of DP LIBS system was performed allowing its use for different soil and the use of different emission lines. • The DP LIBS system improved the analytical performances of the technique up to about 5 times, when compared with SP LIBS. • The IR laser provided the best performance in re-heating the plasma.

  13. Combined raman spectrometer/laser-induced breakdown spectrometer design concept

    Science.gov (United States)

    Bazalgette Courrèges-Lacoste, Gregory; Ahlers, Berit; Boslooper, Erik; Rull-Perez, Fernando; Maurice, Sylvestre

    2017-11-01

    Amongst the different instruments that have been preselected to be on-board the Pasteur payload on ExoMars is the Raman/ Laser Induced Breakdown Spectroscopy (LIBS) instrument. Raman spectroscopy and LIBS will be integrated into a single instrument sharing many hardware commonalities. An international team under the lead of TNO has been gathered to produce a design concept for a combined Raman Spectrometer/ LIBS Elegant Bread-Board (EBB). The instrument is based on a specifically designed extremely compact spectrometer with high resolution over a large wavelength range, suitable for both Raman spectroscopy and LIBS measurements. Low mass, size and resources are the main drivers of the instrument's design concept. The proposed design concept, realization and testing programme for the combined Raman/ LIBS EBB is presented as well as background information on Raman and LIBS.

  14. Les médicaments à libération prolongée pour les enfants et les adolescents ayant un trouble de déficit de l’attention avec hyperactivité

    Science.gov (United States)

    Feldman, M; Bélanger, S

    2009-01-01

    Le trouble de déficit de l’attention avec hyperactivité (TDAH) touche un enfant canadien sur 20 et s’associe à un dossier scolaire et à un registre d’emploi défavorables, à des taux élevés de blessures et de consommation de drogues ou d’alcool, à des relations interpersonnelles médiocres, à de mauvaises issues en santé mentale et à une qualité de vie insatisfaisante. Des essais contrôlés démontrent que les médica-ments sont efficaces pour traiter les symptômes de TDAH tandis que des études d’observation indiquent qu’ils s’associent à de meilleures issues sociales et de santé. De nombreuses familles, ainsi que leur médecin traitant, préfèrent les médicaments à libération prolongée (LP) contre le TDAH aux médicaments à libération immédiate (LI) et à action brève. Toutefois, les préparations à LP sont souvent inabor-dables pour les familles, dont un nombre disproportionné fait partie de la strate à faible statut socioéconomique. Le présent document de principes vise à proposer une évaluation critique des données probantes sur l’efficacité relative des médicaments à LP par rapport aux médicaments à LI ainsi que des recommandations au sujet de leur utilisation convenable dans le traitement du TDAH. Lorsque les médicaments sont indiqués, il faut envisager d’utiliser des préparations à LP comme traitement de première intention contre le TDAH parce qu’elles sont plus efficaces et moins susceptibles d’être détournées. Les futures recherches et les analyses coûts-avantages doivent tenir compte à la fois de l’efficacité de médicaments dans des études contrôlées et de leur efficacité clinique en situation réelle ainsi que du potentiel de détournement et de mésusage de ces médicaments. L’industrie, les sociétés d’assurance et le gouvernement doivent collaborer pour rendre ces médicaments accessibles à tous les enfants et adolescents ayant un TDAH.

  15. Effects of house type and early feed restriction on performance and fat deposition in unsexed broilers

    Directory of Open Access Journals (Sweden)

    U Santoso

    2002-06-01

    Full Text Available The present experiment was conducted to evaluate the effects of house type and early feed restriction on performance and fat deposition of unsexed broilers. Four hundreds seven-day old unsexed broilers (Arbor Acres CP 707 were distributed into eight treatment groups. Each treatment group was represented by five replicates of ten broilers each. Two types of house (cage vs litter and four levels of feeding (ad lib., 75% ad lib., 50% ad lib. and 25% ad lib. were tested as treatment factors. Broilers were feed-restricted for 6 days from 7 to 13 days of age and thereafter they were fed ad lib. Feed intake of restricted broilers during restriction period was calculated from feed consumed by ad lib. group in the previous day. Results showed that unsexed broilers raised in litter had higher body weight (P<0.05, lower abdominal fat and higher triglyceride concentration at 42 days of age (P<0.05, and lower liver fat and higher carcass percentage at 56 days of age (P<0.05. Early feed restriction reduced body weight of 42-day old unsexed broilers except for broilers fed 75% ad lib. At 56 days of age, restricted broilers had similar body weight to those fed ad lib. At 56 days of age, broilers fed 25% ad lib. had lower FCR (P<0.05, lower abdominal fat (P<0.05 and lower triglyceride concentration (P<0,05. In conclusion, unsexed broilers fed 25% ad lib. showed compensatory growth with better FCR and lower fat accumulation at 56 days of age. Broilers raised in litter had higher body weight and lower abdominal and liver fat deposition.

  16. Laser Induced Breakdown Spectroscopy Based on Single Beam Splitting and Geometric Configuration for Effective Signal Enhancement

    Science.gov (United States)

    Yang, Guang; Lin, Qingyu; Ding, Yu; Tian, Di; Duan, Yixiang

    2015-01-01

    A new laser induced breakdown spectroscopy (LIBS) based on single-beam-splitting (SBS) and proper optical geometric configuration has been initially explored in this work for effective signal enhancement. In order to improve the interaction efficiency of laser energy with the ablated material, a laser beam operated in pulse mode was divided into two streams to ablate/excite the target sample in different directions instead of the conventional one beam excitation in single pulse LIBS (SP-LIBS). In spatial configuration, the laser beam geometry plays an important role in the emission signal enhancement. Thus, an adjustable geometric configuration with variable incident angle between the two splitted laser beams was constructed for achieving maximum signal enhancement. With the optimized angles of 60° and 70° for Al and Cu atomic emission lines at 396.15 nm and 324.75 nm respectively, about 5.6- and 4.8-folds signal enhancements were achieved for aluminum alloy and copper alloy samples compared to SP-LIBS. Furthermore, the temporal analysis, in which the intensity of atomic lines in SP-LIBS decayed at least ten times faster than the SBS-LIBS, proved that the energy coupling efficiency of SBS-LIBS was significantly higher than that of SP-LIBS. PMID:25557721

  17. Arabidopsis phospholipase Dδ is involved in basal defense and nonhost resistance to powdery mildew fungi

    DEFF Research Database (Denmark)

    Pinosa, Francesco; Buhot, Nathalie; Kwaaitaal, Mark Adrianus Cornelis J

    2013-01-01

    resistance against Bgh, and chemical inhibition of PLDs in plants mutated in PLDδ indicated that this isoform alone is involved in Bgh resistance. In addition, we confirmed the involvement of PLDδ in penetration resistance against another nonadapted pea powdery mildew fungus, Erysiphe pisi. A green...... fluorescent protein fusion of PLDδ localized to the plasma membrane at the Bgh attack site, where it surrounded the cell wall reinforcement. Furthermore, in the pldδ mutant, transcriptional up-regulation of early microbe-associated molecular pattern response genes was delayed after chitin stimulation...

  18. Comparative study on fast classification of brick samples by combination of principal component analysis and linear discriminant analysis using stand-off and table-top laser-induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Vítková, Gabriela [Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 5/A14, 625 00 Brno (Czech Republic); Prokeš, Lubomír [Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 5/A14, 625 00 Brno (Czech Republic); Department of Physical Electronics, Faculty of Science, Masaryk University, Kotlářská 2, 611 37 Brno (Czech Republic); CEPLANT, R and D Center for Low-Cost Plasma and Nanotechnology Surface Modifications, Masaryk University, Kotlářská 2, 611 37 Brno (Czech Republic); Novotný, Karel [Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 5/A14, 625 00 Brno (Czech Republic); CEITEC — Central European Institute of Technology, Masaryk University, Kamenice 5, 625 00 Brno (Czech Republic); Pořízka, Pavel [Institute of Physical Engineering, Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno (Czech Republic); Novotný, Jan [CEITEC — Central European Institute of Technology, Brno University of Technology, Technická 3058/10, 616 00 Brno (Czech Republic); Všianský, Dalibor [Department of Geological Sciences, Faculty of Science, Masaryk University, Kotlářská 2, 611 37 Brno (Czech Republic); Čelko, Ladislav [CEITEC — Central European Institute of Technology, Brno University of Technology, Technická 3058/10, 616 00 Brno (Czech Republic); and others

    2014-11-01

    Focusing on historical aspect, during archeological excavation or restoration works of buildings or different structures built from bricks it is important to determine, preferably in-situ and in real-time, the locality of bricks origin. Fast classification of bricks on the base of Laser-Induced Breakdown Spectroscopy (LIBS) spectra is possible using multivariate statistical methods. Combination of principal component analysis (PCA) and linear discriminant analysis (LDA) was applied in this case. LIBS was used to classify altogether the 29 brick samples from 7 different localities. Realizing comparative study using two different LIBS setups — stand-off and table-top it is shown that stand-off LIBS has a big potential for archeological in-field measurements. - Highlights: • Comparison of two potentially field-deployable LIBS setups is introduced. • The aim is classification of LIBS spectra of brick samples into several localities. • LDA filled with PCA scores is proposed as an effective classification method. • An influence of brick firing temperature on LIBS spectra is discovered and examined.

  19. Elemental profiling of laser cladded multilayer coatings by laser induced breakdown spectroscopy and energy dispersive X-ray spectroscopy

    Science.gov (United States)

    Lednev, V. N.; Sdvizhenskii, P. A.; Filippov, M. N.; Grishin, M. Ya.; Filichkina, V. A.; Stavertiy, A. Ya.; Tretyakov, R. S.; Bunkin, A. F.; Pershin, S. M.

    2017-09-01

    Multilayer tungsten carbide wear resistant coatings were analyzed by laser induced breakdown spectroscopy (LIBS) and energy dispersive X-ray (EDX) spectroscopy. Coaxial laser cladding technique was utilized to produce tungsten carbide coating deposited on low alloy steel substrate with additional inconel 625 interlayer. EDX and LIBS techniques were used for elemental profiling of major components (Ni, W, C, Fe, etc.) in the coating. A good correlation between EDX and LIBS data was observed while LIBS provided additional information on light element distribution (carbon). A non-uniform distribution of tungsten carbide grains along coating depth was detected by both LIBS and EDX. In contrast, horizontal elemental profiling showed a uniform tungsten carbide particles distribution. Depth elemental profiling by layer-by-layer LIBS analysis was demonstrated to be an effective method for studying tungsten carbide grains distribution in wear resistant coating without any sample preparation.

  20. Automotive Lithium-ion Cell Manufacturing: Regional Cost Structures and Supply Chain Considerations

    Energy Technology Data Exchange (ETDEWEB)

    Donald Chung, Emma Elgqvist, and Shriram Santhanagopalan

    2016-04-01

    Manufacturing capacity for lithium-ion batteries (LIBs) — which power many consumer electronics and are increasingly used to power electric vehicles — is heavily concentrated in East Asia. To illuminate the factors that drive regional competitiveness in automotive LIB cell production, this study models cell manufacturing cost and minimum sustainable price, and examines development of LIB supply chains and current LIB market conditions. The study shows that factors driving the cost competitiveness of LIB manufacturing locations are mostly built—supply chain developments and competition, access to materials, and production expertise. Some regional costs — including cost of capital, labor, and materials — are significant and should be considered.

  1. Study on the effect of beam propagation through atmospheric turbulence on standoff nanosecond laser induced breakdown spectroscopy measurements.

    Science.gov (United States)

    Laserna, J J; Reyes, R Fernández; González, R; Tobaria, L; Lucena, P

    2009-06-08

    We report on an experimental study of the effect of atmospheric turbulence on laser induced breakdown spectroscopy (LIBS) measurements. The characteristics of the atmosphere dictate specific performance constraints to this technology. Unlike classical laboratory LIBS systems where the distance to the sample is well known and characterized, LIBS systems working at several tens of meters to the target have specific atmospheric propagation conditions that cause the quality of the LIBS signals to be affected to a significant extent. Using a new LIBS based sensor system fitted with a nanosecond laser emitting at 1064 nm, propagation effects at distances of up to 120 m were investigated. The effects observed include wander and scintillation in the outgoing laser beam and in the return atomic emission signal. Plasmas were formed on aluminium targets. Average signal levels and signal fluctuations are measured so the effect of atmospheric turbulence on LIBS measurements is quantified.

  2. Double pulse laser induced breakdown spectroscopy: A potential tool for the analysis of contaminants and macro/micronutrients in organic mineral fertilizers.

    Science.gov (United States)

    Nicolodelli, Gustavo; Senesi, Giorgio Saverio; de Oliveira Perazzoli, Ivan Luiz; Marangoni, Bruno Spolon; De Melo Benites, Vinícius; Milori, Débora Marcondes Bastos Pereira

    2016-09-15

    Organic fertilizers are obtained from waste of plant or animal origin. One of the advantages of organic fertilizers is that, from the composting, it recycles waste-organic of urban and agriculture origin, whose disposal would cause environmental impacts. Fast and accurate analysis of both major and minor/trace elements contained in organic mineral and inorganic fertilizers of new generation have promoted the application of modern analytical techniques. In particular, laser induced breakdown spectroscopy (LIBS) is showing to be a very promising, quick and practical technique to detect and measure contaminants and nutrients in fertilizers. Although, this technique presents some limitations, such as a low sensitivity, if compared to other spectroscopic techniques, the use of double pulse (DP) LIBS is an alternative to the conventional LIBS in single pulse (SP). The macronutrients (Ca, Mg, K, P), micronutrients (Cu, Fe, Na, Mn, Zn) and contaminant (Cr) in fertilizer using LIBS in SP and DP configurations were evaluated. A comparative study for both configurations was performed using optimized key parameters for improving LIBS performance. The limit of detection (LOD) values obtained by DP LIBS increased up to seven times as compared to SP LIBS. In general, the marked improvement obtained when using DP system in the simultaneous LIBS quantitative determination for fertilizers analysis could be ascribed to the larger ablated mass of the sample. The results presented in this study show the promising potential of the DP LIBS technique for a qualitative analysis in fertilizers, without requiring sample preparation with chemical reagents. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Double pulse laser induced breakdown spectroscopy applied to natural and artificial materials from cultural heritages

    International Nuclear Information System (INIS)

    Brai, Maria; Gennaro, Gaetano; Schillaci, Tiziano; Tranchina, Luigi

    2009-01-01

    The laser-induced breakdown spectroscopy (LIBS) is an applied physical technique that has shown in recent years its great potential for rapid qualitative analysis of materials. Thanks to the possibility to implement a portable instrument that perform LIBS analysis, this technique is revealed to be particularly useful for in situ analysis in the field of cultural heritages. The purpose of this work is to evaluate the potentiality of LIBS technique in the field of cultural heritages, with respect to the chemical characterization of complex matrix as calcareous and refractory materials for further quantitative analyses on cultural heritages. X-Ray Fluorescence (XRF) analyses were used as reference. Calibration curves of certified materials used as standards were obtained by XRF analyses. The LIBS measurements were performed with a new mobile instrument called Modi (Mobile Double pulse Instrument for LIBS Analysis). The XRF analyses were performed with a portable instrument ArtTAX. LIBS and XRF measurement were performed on both reference materials and samples (bricks and mortars) sampled in the ancient Greek-Roman Theatre of Taormina. Although LIBS measurements performed on reference materials have shown non linear response to concentrations, and so we were not able to obtain quantitative results, an integrated study of XRF and LIBS signals permitted us to distinguish among chemical features and degradation state of measured building materials.

  4. Double pulse laser induced breakdown spectroscopy applied to natural and artificial materials from cultural heritages

    Energy Technology Data Exchange (ETDEWEB)

    Brai, Maria; Gennaro, Gaetano [Dipartimento di Fisica e Tecnologie Relative, Universita di Palermo, Viale delle Scienze Ed.18, 90128 Palermo (Italy); Schillaci, Tiziano, E-mail: tschillaci@unipa.i [Dipartimento di Fisica e Tecnologie Relative, Universita di Palermo, Viale delle Scienze Ed.18, 90128 Palermo (Italy); Tranchina, Luigi [Dipartimento di Fisica e Tecnologie Relative, Universita di Palermo, Viale delle Scienze Ed.18, 90128 Palermo (Italy)

    2009-10-15

    The laser-induced breakdown spectroscopy (LIBS) is an applied physical technique that has shown in recent years its great potential for rapid qualitative analysis of materials. Thanks to the possibility to implement a portable instrument that perform LIBS analysis, this technique is revealed to be particularly useful for in situ analysis in the field of cultural heritages. The purpose of this work is to evaluate the potentiality of LIBS technique in the field of cultural heritages, with respect to the chemical characterization of complex matrix as calcareous and refractory materials for further quantitative analyses on cultural heritages. X-Ray Fluorescence (XRF) analyses were used as reference. Calibration curves of certified materials used as standards were obtained by XRF analyses. The LIBS measurements were performed with a new mobile instrument called Modi (Mobile Double pulse Instrument for LIBS Analysis). The XRF analyses were performed with a portable instrument ArtTAX. LIBS and XRF measurement were performed on both reference materials and samples (bricks and mortars) sampled in the ancient Greek-Roman Theatre of Taormina. Although LIBS measurements performed on reference materials have shown non linear response to concentrations, and so we were not able to obtain quantitative results, an integrated study of XRF and LIBS signals permitted us to distinguish among chemical features and degradation state of measured building materials.

  5. Comparative measurements of mineral elements in milk powders with laser-induced breakdown spectroscopy and inductively coupled plasma atomic emission spectroscopy.

    Science.gov (United States)

    Lei, W Q; El Haddad, J; Motto-Ros, V; Gilon-Delepine, N; Stankova, A; Ma, Q L; Bai, X S; Zheng, L J; Zeng, H P; Yu, J

    2011-07-01

    Mineral elements contained in commercially available milk powders, including seven infant formulae and one adult milk, were analyzed with inductively coupled plasma atomic emission spectrometry (ICP-AES) and laser-induced breakdown spectroscopy (LIBS). The purpose of this work was, through a direct comparison of the analytical results, to provide an assessment of the performance of LIBS, and especially of the procedure of calibration-free LIBS (CF-LIBS), to deal with organic compounds such as milk powders. In our experiments, the matrix effect was clearly observed affecting the analytical results each time laser ablation was employed for sampling. Such effect was in addition directly observed by determining the physical parameters of the plasmas induced on the different samples. The CF-LIBS procedure was implemented to deduce the concentrations of Mg and K with Ca as the internal reference element. Quantitative analytical results with CF-LIBS were validated with ICP-AES measurements and nominal concentrations specified for commercial milks. The obtained good results with the CF-LIBS procedure demonstrate its capacity to take into account the difference in physical parameters of the plasma in the calculation of the concentrations of mineral elements, which allows a significant reduction of the matrix effect related to laser ablation. We finally discuss the way to optimize the implementation of the CF-LIBS procedure for the analysis of mineral elements in organic materials.

  6. Comparison of laser induced breakdown spectroscopy and spark induced breakdown spectroscopy for determination of mercury in soils

    International Nuclear Information System (INIS)

    Srungaram, Pavan K.; Ayyalasomayajula, Krishna K.; Yu-Yueh, Fang; Singh, Jagdish P.

    2013-01-01

    Mercury is a toxic element found throughout the environment. Elevated concentrations of mercury in soils are quite hazardous to plants growing in these soils and also the runoff of soils to nearby water bodies contaminates the water, endangering the flora and fauna of that region. This makes continuous monitoring of mercury very essential. This work compares two potential spectroscopic methods (laser induced breakdown spectroscopy (LIBS) and spark induced breakdown spectroscopy (SIBS)) at their optimum experimental conditions for mercury monitoring. For LIBS, pellets were prepared from soil samples of known concentration for generating a calibration curve while for SIBS, soil samples of known concentration were used in the powder form. The limits of detection (LODs) of Hg in soil were calculated from the Hg calibration curves. The LOD for mercury in soil calculated using LIBS and SIBS is 483 ppm and 20 ppm, respectively. The detection range for LIBS and SIBS is discussed. - Highlights: • We compared SIBS and LIBS for mercury (Hg) measurements in soil. • Hg 546.07 nm line was selected for both LIBS and SIBS measurements. • Limit of detection for Hg was found to be 20 ppm with SIBS and 483 ppm with LIBS

  7. Comparison of laser induced breakdown spectroscopy and spark induced breakdown spectroscopy for determination of mercury in soils

    Energy Technology Data Exchange (ETDEWEB)

    Srungaram, Pavan K.; Ayyalasomayajula, Krishna K.; Yu-Yueh, Fang; Singh, Jagdish P., E-mail: singh@icet.msstate.edu

    2013-09-01

    Mercury is a toxic element found throughout the environment. Elevated concentrations of mercury in soils are quite hazardous to plants growing in these soils and also the runoff of soils to nearby water bodies contaminates the water, endangering the flora and fauna of that region. This makes continuous monitoring of mercury very essential. This work compares two potential spectroscopic methods (laser induced breakdown spectroscopy (LIBS) and spark induced breakdown spectroscopy (SIBS)) at their optimum experimental conditions for mercury monitoring. For LIBS, pellets were prepared from soil samples of known concentration for generating a calibration curve while for SIBS, soil samples of known concentration were used in the powder form. The limits of detection (LODs) of Hg in soil were calculated from the Hg calibration curves. The LOD for mercury in soil calculated using LIBS and SIBS is 483 ppm and 20 ppm, respectively. The detection range for LIBS and SIBS is discussed. - Highlights: • We compared SIBS and LIBS for mercury (Hg) measurements in soil. • Hg 546.07 nm line was selected for both LIBS and SIBS measurements. • Limit of detection for Hg was found to be 20 ppm with SIBS and 483 ppm with LIBS.

  8. Effects of house type and early feed restriction on performance and fat deposition in unsexed broilers

    OpenAIRE

    U Santoso

    2002-01-01

    The present experiment was conducted to evaluate the effects of house type and early feed restriction on performance and fat deposition of unsexed broilers. Four hundreds seven-day old unsexed broilers (Arbor Acres CP 707) were distributed into eight treatment groups. Each treatment group was represented by five replicates of ten broilers each. Two types of house (cage vs litter) and four levels of feeding (ad lib., 75% ad lib., 50% ad lib. and 25% ad lib.) were tested as treatment factors. B...

  9. Combined Raman spectrometer/laser-induced breakdown spectrometer for the next ESA mission to Mars

    Science.gov (United States)

    Bazalgette Courrèges-Lacoste, Grégory; Ahlers, Berit; Pérez, Fernando Rull

    2007-12-01

    Among the different instruments that have been pre-selected to be on-board the Pasteur payload on ExoMars is the Raman/ laser induced breakdown spectroscopy (LIBS) instrument. Raman spectroscopy and LIBS will be integrated into a single instrument sharing many hardware commonalities. An international team under the lead of TNO has been gathered to produce a design concept for a combined Raman spectrometer/LIBS elegant bread-board (EBB). The instrument is based on a specially designed, extremely compact, spectrometer with high resolution over a large wavelength range, suitable for both Raman spectroscopy and LIBS measurements. Low mass, size and power consumption are the main drivers of the instrument's design concept. In this paper, science objectives for the combined instrument are detailed. Background information on Raman spectroscopy and LIBS are presented, focussing on the synergy of these two techniques. In the last section, the instrument concept resulting from the assessment of the feasibility of the combined Raman/LIBS EBB is presented.

  10. Determination of elemental composition of coffee using UV-pulsed laser induced breakdown spectroscopy

    International Nuclear Information System (INIS)

    Gondal, M. A.; Baig, Umair; Dastageer, M. A.; Sarwar, Mohsin

    2016-01-01

    A detection system based on laser induced breakdown spectroscopy (LIBS) was built using 266 nm wavelength pulsed laser from the fourth harmonic of Nd:YAG laser, 500 mm spectrograph and gated ICCD camera with built-in delay generator. The LIBS system was used to study the elemental composition in coffee available in the local market of Saudi Arabia for the detection of elements in coffee samples. The LIBS spectrum of coffee sample revealed the presence magnesium, calcium, aluminum, copper, sodium, barium, bromine, cobalt, chromium, cerium manganese and molybdenum. Atomic transition line of sodium is used to study the parametric dependence of LIBS signal. The study of the dependence of LIBS signal on the laser pulse energy is proven to be linear and the dependence of LIBS signal on the time delay between the excitation and data acquisition showed a typical increase, a peak value and a decrease with the optimum excitation – acquisition delay at 400 ns.

  11. Generation and management of waste electric vehicle batteries in China.

    Science.gov (United States)

    Xu, ChengJian; Zhang, Wenxuan; He, Wenzhi; Li, Guangming; Huang, Juwen; Zhu, Haochen

    2017-09-01

    With the increasing adoption of EVs (electric vehicles), a large number of waste EV LIBs (electric vehicle lithium-ion batteries) were generated in China. Statistics showed generation of waste EV LIBs in 2016 reached approximately 10,000 tons, and the amount of them would be growing rapidly in the future. In view of the deleterious effects of waste EV LIBs on the environment and the valuable energy storage capacity or materials that can be reused in them, China has started emphasizing the management, reuse, and recycling of them. This paper presented the generation trend of waste EV LIBs and focused on interrelated management development and experience in China. Based on the situation of waste EV LIBs management in China, existing problems were analyzed and summarized. Some recommendations were made for decision-making organs to use as valuable references to improve the management of waste EV LIBs and promote the sustainable development of EVs.

  12. Determination of elemental composition of coffee using UV-pulsed laser induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Gondal, M. A., E-mail: magondal@kfupm.edu.sa; Baig, Umair; Dastageer, M. A.; Sarwar, Mohsin [Laser Research Group, Physics Department, King Fahd University of Petroleum and Minerals, P.O Box 5047, Dhahran 31261 (Saudi Arabia)

    2016-06-10

    A detection system based on laser induced breakdown spectroscopy (LIBS) was built using 266 nm wavelength pulsed laser from the fourth harmonic of Nd:YAG laser, 500 mm spectrograph and gated ICCD camera with built-in delay generator. The LIBS system was used to study the elemental composition in coffee available in the local market of Saudi Arabia for the detection of elements in coffee samples. The LIBS spectrum of coffee sample revealed the presence magnesium, calcium, aluminum, copper, sodium, barium, bromine, cobalt, chromium, cerium manganese and molybdenum. Atomic transition line of sodium is used to study the parametric dependence of LIBS signal. The study of the dependence of LIBS signal on the laser pulse energy is proven to be linear and the dependence of LIBS signal on the time delay between the excitation and data acquisition showed a typical increase, a peak value and a decrease with the optimum excitation – acquisition delay at 400 ns.

  13. Laser-Induced Breakdown Spectroscopy for Qualitative Analysis of Metals in Simulated Martian Soils

    Science.gov (United States)

    Mowry, Curtis; Milofsky, Rob; Collins, William; Pimentel, Adam S.

    2017-01-01

    This laboratory introduces students to laser-induced breakdown spectroscopy (LIBS) for the analysis of metals in soil and rock samples. LIBS employs a laser-initiated spark to induce electronic excitation of metal atoms. Ensuing atomic emission allows for qualitative and semiquantitative analysis. The students use LIBS to analyze a series of…

  14. Green-synthetized silver nanoparticles for Nanoparticle-Enhanced Laser Induced Breakdown Spectroscopy (NELIBS) using a mobile instrument

    Science.gov (United States)

    Poggialini, F.; Campanella, B.; Giannarelli, S.; Grifoni, E.; Legnaioli, S.; Lorenzetti, G.; Pagnotta, S.; Safi, A.; Palleschi, V.

    2018-03-01

    When compared to other analytical techniques, LIBS shows relatively low precision and, generally, high Limits of Detection (LODs). Until recently, the attempts in improving the LIBS performances have been based on the use of more stable/powerful lasers, high sensitivity detectors or controlled environmental parameters. This can hinder the competitiveness of LIBS by increasing the instrumental setup cost and the difficulty of operation. Sample treatment has proved to be a viable and simple way to increase the LIBS signal; in particular, the Nanoparticle-Enhanced Laser Induced Breakdown Spectroscopy (NELIBS) methodology uses a deposition of metal nanoparticles on the sample to greatly increase the emission of the LIBS plasma. In this work, we used a simple, fast, "green" and low-cost method to synthetize silver nanoparticles by using coffee extract as reducing agents for a silver nitrate solution. This allowed us to obtain nanoparticles of about 25 nm in diameter. We then explored the application of such nanoparticles to the NELIBS analysis of metallic samples with a mobile LIBS instrument. By adjusting the laser parameters and optimizing the sample preparation procedure, we obtained a NELIBS signal that is 4 times the LIBS one. This showed the potential of green-synthetized nanoparticle for NELIBS applications and suggests the possibility of an in-situ application of the technique.

  15. Analytical performances of laser-induced micro-plasma of Al samples with single and double ultrashort pulses in air and with Ar-jet: A comparative study

    International Nuclear Information System (INIS)

    Semerok, A.; Dutouquet, C.

    2014-01-01

    Ultrashort pulse laser microablation coupled with optical emission spectroscopy was under study to obtain several micro-LIBS analytical features (shot-to-shot reproducibility, spectral line intensity and lifetime, calibration curves, detection limits). Laser microablation of Al matrix samples with known Cu- and Mg-concentrations was performed by single and double pulses of 50 fs and 1 ps pulse duration in air and with Ar-jet. The micro-LIBS analytical features obtained under different experimental conditions were characterized and compared. The highest shot-to-shot reproducibility and gain in plasma spectral line intensity were obtained with double pulses with Ar-jet for both 50 fs and 1 ps pulse durations. The best calibration curves were obtained with 1 ps pulse duration with Ar-jet. Micro-LIBS with ultrashort double pulses may find its effective application for surface elemental microcartography. - Highlights: • Analytical performances of micro-LIBS with ultrashort double pulses were studied. • The maximal line intensity gain of 20 was obtained with double pulses and Ar-jet. • LIBS gain was obtained without additional ablation of a sample by the second pulse. • LIBS properties were almost the same for both 50 fs and 1 ps pulses. • The micro-LIBS detection limit was around 35 ppm

  16. Laser Induced Breakdown Spectroscopy in archeometry: A review of its application and future perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Spizzichino, Valeria, E-mail: valeria.spizzichino@enea.it; Fantoni, Roberta

    2014-09-01

    Laser Induced Breakdown Spectroscopy (LIBS) in the last decades has been more and more applied to the field of Cultural Heritage with great results obtained either alone or in combination with complementary laser techniques. Its ability to analyze, with a minimal loss, different kinds of materials in laboratory, in situ and even in hostile environments has been highly appreciated. The main aim of this paper is to present a review of LIBS applications in the interdisciplinary field of archeometry. The LIBS technique is shortly described both from a theoretical and practical point of view, discussing the instrumental setup, also in comparison with typical features of laser induced fluorescence (LIF) and Raman spectroscopy apparata. The complementary with multivariate analysis, a method that can help in reducing data set dimensions and in pulling out effective information, is stressed. In particular the role of LIBS in Cultural Heritage material characterization, recognition of fakes and indirect dating is described, reporting general considerations and case studies on metal alloys, mural paintings, decorated ceramics, glasses, stones and gems. - Highlights: • Applications of LIBS to archeometry are reviewed. • Complementary among LIBS, LIF, Raman and multivariate analysis is highlighted. • Three major areas of successful LIBS application in archeometry are identified. • Significant results have been presented for several different materials.

  17. Development of laser induced breakdown spectroscopy for studying erosion, deposition, and fuel retention in ASDEX Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Paris, Peeter; Piip, Kaarel [Institute of Physics, University of Tartu, Tartu (Estonia); Hakola, Antti [VTT Technical Research Centre of Finland, Espoo (Finland); Laan, Matti, E-mail: matti.laan@ut.ee [Institute of Physics, University of Tartu, Tartu (Estonia); Aints, Märt [Institute of Physics, University of Tartu, Tartu (Estonia); Koivuranta, Seppo; Likonen, Jari [VTT Technical Research Centre of Finland, Espoo (Finland); Lissovski, Aleksandr [Institute of Physics, University of Tartu, Tartu (Estonia); Mayer, Matej [Max-Planck-Institut für Plasmaphysik, Garching (Germany); Neu, Rudolf [Max-Planck-Institut für Plasmaphysik, Garching (Germany); Technische Universität München, Fachgebt Plasma-Material-Wechelwirkung, Garching (Germany); Rohde, Volker; Sugiyama, Kazuyoshi [Max-Planck-Institut für Plasmaphysik, Garching (Germany)

    2015-10-15

    Highlights: • LIBS development for in situ monitoring of first walls of fusion reactors. • Testing of samples extracted from the divertor tiles of ASDEX Upgrade. • Reliable detection of deuterium depth profiles. • A method of LIBS data processing which allows to find the elemental depth profiles. • Comparison of LIBS results with those of other surface characterization methods. - Abstract: The paper deals with the development of laser induced breakdown spectroscopy (LIBS) into an in situ method for studying erosion/deposition processes at the first walls of fusion reactors. To this end, samples extracted from the divertor tiles of ASDEX Upgrade after the 2009 plasma operations were analyzed using LIBS for their composition and the results were compared with other post mortem deposition data. Quantitative depth profiles for the elemental concentrations were extracted from LIBS spectra by applying a novel data processing method. In addition, both multiline and multispot averaging procedures were applied to reduce fluctuations in the data. The LIBS concentration profiles matched qualitatively with those given by secondary ion mass spectrometry and quantitatively with the ion-beam data. The deuterium content of the samples could be reliably determined if the surface densities were >10{sup 17} at/cm{sup 2}.

  18. Effect of the wavelength on laser induced breakdown spectrometric analysis of archaeological bone

    Energy Technology Data Exchange (ETDEWEB)

    Kasem, M.A. [National Institute of Laser Enhanced Science (NILES), Cairo University, Giza (Egypt); Gonzalez, J.J.; Russo, R.E. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Harith, M.A., E-mail: mharithm@niles.edu.eg [National Institute of Laser Enhanced Science (NILES), Cairo University, Giza (Egypt)

    2014-11-01

    The analytical exploitation of the laser induced plasma suffers from its transient behavior due to some nonlinear effects. These phenomena are matrix-dependent and limit the use of LIBS to mostly semi-quantitative precision. The plasma parameters have to be kept as constant as possible during LIBS measurements. Studying archaeological bone samples using LIBS technique could be more difficult since these samples are less tough in their texture than many other solid samples. Thus, the ablation process could change the sample morphological features rapidly resulting in poor reproducibility and statistics. Furthermore archaeological bones are subjected to diagenesis effects due to burial environment and postmortem effects. In the present work comparative analytical study of UV (266 nm) and IR (1064 nm) LIBS for archaeological bone samples belonging to four ancient Egyptian dynasties representing the middle kingdom (1980–1630 BC), 2nd intermediate period (1630–1539/23 BC), Roman–Greek period (30 BC–A.D. 395) and the late period (664–332 BC). Measurements have been performed under identical experimental conditions except the laser wavelength to examine its effects. Elemental fluctuations within the same dynasty were studied for reliable information about each dynasty. The analytical results demonstrated that UV-LIBS gives a more realistic picture for bone elemental composition within the same dynasty, and bone ash could be more suitable as a reference material for bone calibration in the case of UV-LIBS. - Highlights: • UV and IR LIBS for archaeological bone samples have been performed. • Elemental fluctuations within the same dynasty were studied. • UV-LIBS gave realistic picture for bone elemental composition for the same dynasty. • Depth profile for Sr/Ca concentration was an indicator for the diagenesis effect. • Bone ash is the most suitable for calcified tissue calibration for UV-LIBS.

  19. Effect of the wavelength on laser induced breakdown spectrometric analysis of archaeological bone

    International Nuclear Information System (INIS)

    Kasem, M.A.; Gonzalez, J.J.; Russo, R.E.; Harith, M.A.

    2014-01-01

    The analytical exploitation of the laser induced plasma suffers from its transient behavior due to some nonlinear effects. These phenomena are matrix-dependent and limit the use of LIBS to mostly semi-quantitative precision. The plasma parameters have to be kept as constant as possible during LIBS measurements. Studying archaeological bone samples using LIBS technique could be more difficult since these samples are less tough in their texture than many other solid samples. Thus, the ablation process could change the sample morphological features rapidly resulting in poor reproducibility and statistics. Furthermore archaeological bones are subjected to diagenesis effects due to burial environment and postmortem effects. In the present work comparative analytical study of UV (266 nm) and IR (1064 nm) LIBS for archaeological bone samples belonging to four ancient Egyptian dynasties representing the middle kingdom (1980–1630 BC), 2nd intermediate period (1630–1539/23 BC), Roman–Greek period (30 BC–A.D. 395) and the late period (664–332 BC). Measurements have been performed under identical experimental conditions except the laser wavelength to examine its effects. Elemental fluctuations within the same dynasty were studied for reliable information about each dynasty. The analytical results demonstrated that UV-LIBS gives a more realistic picture for bone elemental composition within the same dynasty, and bone ash could be more suitable as a reference material for bone calibration in the case of UV-LIBS. - Highlights: • UV and IR LIBS for archaeological bone samples have been performed. • Elemental fluctuations within the same dynasty were studied. • UV-LIBS gave realistic picture for bone elemental composition for the same dynasty. • Depth profile for Sr/Ca concentration was an indicator for the diagenesis effect. • Bone ash is the most suitable for calcified tissue calibration for UV-LIBS

  20. Leveraging the Libguides Platform for Electronic Resources Access Assistance

    Science.gov (United States)

    Erb, Rachel A.; Erb, Brian

    2014-01-01

    This case study offers an alternative use of LibGuides beyond its intended purpose to offer course and subject guides. LibGuides have become an integral part of the virtual instruction landscape at Colorado State University (CSU) Libraries. We discovered that the LibGuides platform can also be effectively harnessed to provide support for…

  1. Prospects for laser-induced breakdown spectroscopy for biomedical applications: a review.

    Science.gov (United States)

    Singh, Vivek Kumar; Rai, Awadhesh Kumar

    2011-09-01

    We review the different spectroscopic techniques including the most recent laser-induced breakdown spectroscopy (LIBS) for the characterization of materials in any phase (solid, liquid or gas) including biological materials. A brief history of the laser and its application in bioscience is presented. The development of LIBS, its working principle and its instrumentation (different parts of the experimental set up) are briefly summarized. The generation of laser-induced plasma and detection of light emitted from this plasma are also discussed. The merit and demerits of LIBS are discussed in comparison with other conventional analytical techniques. The work done using the laser in the biomedical field is also summarized. The analysis of different tissues, mineral analysis in different organs of the human body, characterization of different types of stone formed in the human body, analysis of biological aerosols using the LIBS technique are also summarized. The unique abilities of LIBS including detection of molecular species and calibration-free LIBS are compared with those of other conventional techniques including atomic absorption spectroscopy, inductively coupled plasma atomic emission spectroscopy and mass spectroscopy, and X-ray fluorescence.

  2. Anomaly Monitoring Method for Key Components of Satellite

    Directory of Open Access Journals (Sweden)

    Jian Peng

    2014-01-01

    Full Text Available This paper presented a fault diagnosis method for key components of satellite, called Anomaly Monitoring Method (AMM, which is made up of state estimation based on Multivariate State Estimation Techniques (MSET and anomaly detection based on Sequential Probability Ratio Test (SPRT. On the basis of analysis failure of lithium-ion batteries (LIBs, we divided the failure of LIBs into internal failure, external failure, and thermal runaway and selected electrolyte resistance (Re and the charge transfer resistance (Rct as the key parameters of state estimation. Then, through the actual in-orbit telemetry data of the key parameters of LIBs, we obtained the actual residual value (RX and healthy residual value (RL of LIBs based on the state estimation of MSET, and then, through the residual values (RX and RL of LIBs, we detected the anomaly states based on the anomaly detection of SPRT. Lastly, we conducted an example of AMM for LIBs, and, according to the results of AMM, we validated the feasibility and effectiveness of AMM by comparing it with the results of threshold detective method (TDM.

  3. Elemental analysis by surface-enhanced Laser-Induced Breakdown Spectroscopy combined with liquid–liquid microextraction

    International Nuclear Information System (INIS)

    Aguirre, M.A.; Legnaioli, S.; Almodóvar, F.; Hidalgo, M.; Palleschi, V.; Canals, A.

    2013-01-01

    In this work, the possibility of using Laser-Induced Breakdown Spectrometry (LIBS) combined with liquid–liquid microextraction techniques is evaluated as a simple and fast method for trace elemental analysis. Two different strategies for LIBS analysis of manganese contained in microdroplets of extraction solvent (Triton X-114) are studied: (i) analysis by direct laser irradiation of microdroplets; and (ii) analysis by laser irradiation of microdroplets dried on metallic substrates (surface-enhanced LIBS — SENLIBS). Experiments were carried out using synthetic samples with different concentrations of manganese in a 10% w/w Triton X-114 matrix. The analysis by direct laser irradiation of microdroplets showed low precision, sensitivity and poor linearity across the concentration range evaluated (R 2 −1 of Mn. - Highlights: ► LIBS combined with microextraction procedures for trace analysis is proposed. ► The proposed combination depends on LIBS ability to analyze sample microvolumes. ► A surface-enhanced LIBS methodology for microdroplet analysis was evaluated. ► Results indicate this combination to be promising for trace analysis in liquids

  4. Quantitative feed restriction of Pekin breeder ducks from 3 weeks of ...

    African Journals Online (AJOL)

    giving some idea of the physiological phenomena that accompany feed restriction. Ses manlike en 24 vroulike Cherry Valley Pekineendjies is ... bepaaI. Die drie behandelings was as volg: 50% van ad lib.-inname vanaf 3 tot 20 weke; 50% van ad lib. inname vanaf 8 tot 20 weke; en ad lib. inname vir die volle periode.

  5. Laser-induced breakdown spectroscopy to monitor ion cyclotron range of frequency wall cleaning Li/D co-deposition in EAST tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Liu, P.; Wu, D.; Sun, L.Y.; Zhao, D.Y.; Hai, R.; Li, C. [Key Laboratory of Materials Modification by Laser, Ion and Electron Beams, Chinese Ministry of Education, School of Physics and Optical Electronic Technology, Dalian University of Technology, Dalian, 116024 (China); Ding, H., E-mail: hding@dlut.edu.cn [Key Laboratory of Materials Modification by Laser, Ion and Electron Beams, Chinese Ministry of Education, School of Physics and Optical Electronic Technology, Dalian University of Technology, Dalian, 116024 (China); Hu, Z.H.; Wang, L.; Hu, J.S.; Chen, J.L.; Luo, G.N. [Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, Hefei, Anhui 230031 (China)

    2017-05-15

    Highlights: • LIBS was applied to EAST for monitoring the cleaning performance of the first wall using He-ICRF cleaning. • The cleaning performance is effective under helium ambient gas and some measurements have been obtained. • The results also indicate that the influence of magnetic field on LIBS signal is much stronger in helium ambient gas. • The effect of delay time and laser fluence on the LIBS signal has been investigated. - Abstract: In this paper, laser-induced breakdown spectroscopy (LIBS) under magnetic field condition has been studied in laboratory and EAST tokamak. The experimental results reveal that in helium ambient gas, the magnetic field significantly enhances the LIBS signal intensity (∼3 times). The effect of time delay and laser fluence on the intensity of LIBS has been investigated for optimizing the signal to background ratio (S/B). The developed LIBS approach has been applied to monitor the cleaning performance of the first wall in the fusion device of EAST using the ion cyclotron range of frequency (ICRF). The experimental results demonstrate that the cleaning performance for Li/D co-deposition layer is effective under helium ambient gas. The removing rate of Li on the surface of W tile is faster than that on Mo tile in He-ICRF cleaning and the D/(D + H) ratio on Mo tile is higher by ∼1.2 times than that on W tile. This work would indicate the feasibility of using LIBS to monitor the wall cleaning processes in EAST tokamak.

  6. Surface morphology study of some Cu–Ni reference alloys using laser induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Sheta, S.A. [National Institute of Laser Enhanced Science (NILES), Cairo University, 12613, Giza (Egypt); Di Carlo, G.; Ingo, G.M. [Istituto per lo Studio dei Materiali Nanostrutturati (ISMN-CNR), Area della Ricerca Roma 1 Montelibretti, 00016, Monterotondo Scalo, Rome (Italy); Harith, M.A., E-mail: mharithm@niles.edu.eg [National Institute of Laser Enhanced Science (NILES), Cairo University, 12613, Giza (Egypt)

    2016-04-15

    In the present work a detailed study of the surface morphology of purposely-prepared Cu–Ni reference alloys has been performed. These alloys have been prepared via tailored casting methods in order to have samples with same chemical composition and different local chemical enrichments of both metals. A micro-LIBS system for surface spatial scanning was set up based on a second harmonic Nd:YAG laser at 532 nm and using a focusing lens of focal length 7 cm to disclose the local chemical composition variation. Surface morphological scanning was performed for some of the binary Cu–Ni reference alloys to differentiate between chemically homogeneous and heterogeneous alloys. LIBS results were compared with the information of the Scanning Electron Microscope coupled with Energy Dispersive X-ray (SEMEDS) investigation carried out to provide surface local large-area chemical analysis via EDS technique. It has been proved that LIBS is a simple, sensitive and direct technique in the determination of homogeneity or heterogeneity of the sample's surface. The LIBS results have been shown to be more sensitive and accurate in the heterogeneity determination than other used conventional analytical techniques. - Highlights: • Surface LIBS scanning was performed for Cu–Ni reference alloy samples. • LIBS system was based on a 2nd harmonic Nd:YAG laser and a focusing lens (f = 7 cm). • LIBS results were compared with SEM imaging and EDS chemical analysis. • Surface homogeneity and heterogeneity have been differentiated successfully. • LIBS is a sensitive analytical tool in surface metallurgical study.

  7. Kirigami-based stretchable lithium-ion batteries

    Science.gov (United States)

    Song, Zeming; Wang, Xu; Lv, Cheng; An, Yonghao; Liang, Mengbing; Ma, Teng; He, David; Zheng, Ying-Jie; Huang, Shi-Qing; Yu, Hongyu; Jiang, Hanqing

    2015-01-01

    We have produced stretchable lithium-ion batteries (LIBs) using the concept of kirigami, i.e., a combination of folding and cutting. The designated kirigami patterns have been discovered and implemented to achieve great stretchability (over 150%) to LIBs that are produced by standardized battery manufacturing. It is shown that fracture due to cutting and folding is suppressed by plastic rolling, which provides kirigami LIBs excellent electrochemical and mechanical characteristics. The kirigami LIBs have demonstrated the capability to be integrated and power a smart watch, which may disruptively impact the field of wearable electronics by offering extra physical and functionality design spaces. PMID:26066809

  8. Elemental content of enamel and dentin after bleaching of teeth (a comparative study between laser-induced breakdown spectroscopy and x-ray photoelectron spectroscopy)

    Energy Technology Data Exchange (ETDEWEB)

    Imam, H. [National Institute of Laser Enhanced Sciences, NILES, Cairo University, Giza (Egypt); Ahmed, Doaa [Department of Restorative Sciences, Faculty of Dentistry, Alexandria University, Alexandria (Egypt); Eldakrouri, Ashraf [National Institute of Laser Enhanced Sciences, NILES, Cairo University, Giza (Egypt); Department of Optometry and Vision Science, College of Applied Medical Science, King Saud University, Riyadh (Saudi Arabia)

    2013-06-21

    The elemental content of the superficial and inner enamel as well as that of dentin was analyzed using laser-induced breakdown spectroscopy (LIBS) and x-ray photoelectron spectroscopy (XPS) of bleached and unbleached tooth specimens. It is thus clear from the spectral analysis using both the LIBS and XPS technique that elemental changes (though insignificant within the scopes of this study) of variable intensities do occur on the surface of the enamel and extend deeper to reach dentin. The results of the LIBS revealed a slight reduction in the calcium levels in the bleached compared to the control specimens in all the different bleaching groups and in both enamel and dentin. The good correlation found between the LIBS and XPS results demonstrates the possibility of LIBS technique for detection of minor loss in calcium and phosphorus in enamel and dentin.

  9. Materials for lithium-ion battery safety.

    Science.gov (United States)

    Liu, Kai; Liu, Yayuan; Lin, Dingchang; Pei, Allen; Cui, Yi

    2018-06-01

    Lithium-ion batteries (LIBs) are considered to be one of the most important energy storage technologies. As the energy density of batteries increases, battery safety becomes even more critical if the energy is released unintentionally. Accidents related to fires and explosions of LIBs occur frequently worldwide. Some have caused serious threats to human life and health and have led to numerous product recalls by manufacturers. These incidents are reminders that safety is a prerequisite for batteries, and serious issues need to be resolved before the future application of high-energy battery systems. This Review aims to summarize the fundamentals of the origins of LIB safety issues and highlight recent key progress in materials design to improve LIB safety. We anticipate that this Review will inspire further improvement in battery safety, especially for emerging LIBs with high-energy density.

  10. Elemental content of enamel and dentin after bleaching of teeth (a comparative study between laser-induced breakdown spectroscopy and x-ray photoelectron spectroscopy)

    International Nuclear Information System (INIS)

    Imam, H.; Ahmed, Doaa; Eldakrouri, Ashraf

    2013-01-01

    The elemental content of the superficial and inner enamel as well as that of dentin was analyzed using laser-induced breakdown spectroscopy (LIBS) and x-ray photoelectron spectroscopy (XPS) of bleached and unbleached tooth specimens. It is thus clear from the spectral analysis using both the LIBS and XPS technique that elemental changes (though insignificant within the scopes of this study) of variable intensities do occur on the surface of the enamel and extend deeper to reach dentin. The results of the LIBS revealed a slight reduction in the calcium levels in the bleached compared to the control specimens in all the different bleaching groups and in both enamel and dentin. The good correlation found between the LIBS and XPS results demonstrates the possibility of LIBS technique for detection of minor loss in calcium and phosphorus in enamel and dentin.

  11. Computational model of 18650 lithium-ion battery with coupled strain rate and SOC dependencies

    International Nuclear Information System (INIS)

    Xu, Jun; Liu, Binghe; Wang, Xinyi; Hu, Dayong

    2016-01-01

    Highlights: • An anisotropic model to describe mechanical behaviors of LIB is established. • SOC dependency is included in the mechanical model of the jellyroll. • Dynamic effect is considered in the model for LIB. - Abstract: Highly nonlinear structures and constituent materials and hazardous experiment situations have resulted in a pressing need for a numerical mechanical model for lithium-ion battery (LIB). However, such a model is still not well established. In this paper, an anisotropic homogeneous model describing the jellyroll and the battery shell is established and validated through compression, indentation, and bending tests at quasi-static loadings. In this model, state-of-charge (SOC) dependency of the LIB is further included through an analogy with the strain-rate effect. Moreover, with consideration of the inertia and strain-rate effects, the anisotropic homogeneous model is extended into the dynamic regime and proven capable of predicting the dynamic response of the LIB using the drop-weight test. The established model may help to predict extreme cases with high SOCs and crashing speeds with an over 135% improved accuracy compared to traditional models. The established coupled strain rate and SOC dependencies of the numerical mechanical model for the LIB aims to provide a solid step toward unraveling and quantifying the complicated problems for research on LIB mechanical integrity.

  12. Laser-induced breakdown spectroscopy analysis of minerals: Carbonates and silicates

    International Nuclear Information System (INIS)

    McMillan, Nancy J.; Harmon, Russell S.; De Lucia, Frank C.; Miziolek, Andrzej M.

    2007-01-01

    Laser-induced breakdown spectroscopy (LIBS) provides an alternative chemical analytical technique that obviates the issues of sample preparation and sample destruction common to most laboratory-based analytical methods. This contribution explores the capability of LIBS analysis to identify carbonate and silicate minerals rapidly and accurately. Fifty-two mineral samples (18 carbonates, 9 pyroxenes and pyroxenoids, 6 amphiboles, 8 phyllosilicates, and 11 feldspars) were analyzed by LIBS. Two composite broadband spectra (averages of 10 shots each) were calculated for each sample to produce two databases each containing the composite LIBS spectra for the same 52 mineral samples. By using correlation coefficients resulting from the regression of the intensities of pairs of LIBS spectra, all 52 minerals were correctly identified in the database. If the LIBS spectra of each sample were compared to a database containing the other 51 minerals, 65% were identified as a mineral of similar composition from the same mineral family. The remaining minerals were misidentified for two reasons: 1) the mineral had high concentrations of an element not present in the database; and 2) the mineral was identified as a mineral with similar elemental composition from a different family. For instance, the Ca-Mg carbonate dolomite was misidentified as the Ca-Mg silicate diopside. This pilot study suggests that LIBS has promise in mineral identification and in situ analysis of minerals that record geological processes

  13. Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the art

    Science.gov (United States)

    Tognoni, E.; Cristoforetti, G.; Legnaioli, S.; Palleschi, V.

    2010-01-01

    The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal equilibrium, homogeneous plasma, thin radiation, detection of all elements). The inspection of the literature suggests that the CF-LIBS method is more accurate in analyzing metallic alloys rather than dielectrics. However, the full exploitation of the method seems to be still far to come, especially for the lack of a complete characterization of the effects of experimental constraints. However, some general directions can be suggested to help the analyst in designing LIBS measurements in a way which is more suited for CF-LIBS analysis.

  14. Proteomic analysis of fetal programming-related obesity markers.

    Science.gov (United States)

    Lee, Ji Hye; Yoo, Jae Young; You, Young-Ah; Kwon, Woo-Sung; Lee, Sang Mi; Pang, Myung-Geol; Kim, Young Ju

    2015-08-01

    The objectives of this study were to analyze fetal programming in rat brain using proteomic analysis and to identify fetal programming-related obesity markers. Sprague-Dawley rats were divided into four feeding groups: (i) the Ad Libitum (AdLib)/AdLib group was given a normal diet during pregnancy and the lactation period; (ii) the AdLib/maternal food restriction group (FR) was subjected to 50% FR during the lactation period; (iii) the FR/AdLib group was subjected to 50% FR during pregnancy; and (iv) the FR/FR group was subjected to 50% FR during pregnancy and the lactation period. Offspring from each group were sacrificed at 3 weeks of age and whole brains were dissected. To obtain a maximum number of protein markers related to obesity, 2DE and Pathway Studio bioinformatics analysis were performed. The identities of the markers among the selected and candidate proteins were confirmed by Western blotting and immunohistochemistry. Proteomic and bioinformatics analyses revealed that expression of ubiquitin carboxy-terminal hydrolase L1 (UCHL1) and Secernin 1 (SCRN1) were significantly different in the FR/AdLib group compared with the AdLib/AdLib group for both male and female offspring. These findings suggest that UCHL1 and SCRN1 may be used as fetal programming-related obesity markers. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Different milk feeding intensities during the first 4 weeks of rearing in dairy calves: Part 1: Effects on performance and production from birth over the first lactation.

    Science.gov (United States)

    Korst, M; Koch, C; Kesser, J; Müller, U; Romberg, F-J; Rehage, J; Eder, K; Sauerwein, H

    2017-04-01

    We aimed to test the effects of ad libitum feeding of whole milk (WM) or milk replacer (MR) versus restrictive feeding of MR during the first 4 wk of life on growth performance and on milk yield in the first lactation. We studied 57 German Holstein calves (29 females, 28 males) from birth until d 110 of life (trial 1). The 28 females from trial 1 were further studied during their first lactation (trial 2). In trial 1, all calves were randomly allocated at birth to 1 of 3 groups: MR-res [n = 20, 6.78 kg MR (11.5% solids)/calf per day], MR-ad lib (n = 17, 13.8% solids) or WM-ad lib (n = 20). All calves received colostrum ad libitum from their dam until d 3 of age. From d 4 to 27, calves were fed according to their group regimen. From d 28 to 55, all calves received MR-res feeding and were then gradually weaned until d 69. We recorded body weight (until d 110) and feed intake (amount, metabolizable energy, and frequency of liquid feed intake until weaning). We estimated the profitability of the different feeding regimens, taking into account income from milk yield (trial 2) and feed costs during rearing. In trial 1, the calves from WM-ad lib and MR-ad lib had total metabolizable energy intakes 2.02- and 1.65-fold greater than the MR-res group during the first 4 wk of life. During this period, concentrate intake did not differ among groups, but tended to be greater in WM-ad lib than in MR-ad lib calves from d 28 to 69. The MR-res calves visited the automatic feeders more often than the ad libitum-fed groups during differential feeding, but 70% of the visits were unrewarded (calves). When all calves were fed at the MR-res level, the average proportion of unrewarded visits was 65% in all groups. Average daily gain and body weight were greater among MR-ad lib and WM-ad lib calves than among MR-res animals during the first 4 wk of life, but not from d 1 to 110. In trial 2, age at first calving, dry matter intake, and body weight over the first 10 mo of lactation were not

  16. La «Roma del Perú» au tournant du siècle : catholicisme, libéralisme et identité locale à Arequipa (1890-1915

    Directory of Open Access Journals (Sweden)

    Guillemette Martin

    2012-09-01

    Full Text Available Cette étude a pour fil conducteur une approche à la fois locale et discursive des tensions qui accompagnent le processus de sécularisation au Pérou au tournant des XIXe et XXe siècles, à partir de l’étude du cas, à la fois extrême et exemplaire, de la ville d’Arequipa. Durant cette période, la presse arequipénienne est le théâtre d’un débat intense entre des libéraux soucieux de faire entrer la ville dans la modernité et la frange catholique et conservatrice de la population, qui voit ce débat menacer directement le pouvoir politique et moral qu’elle exerce depuis des générations sur l’ensemble de la région. Du fait de la virulence des débats opposant libéraux et catholiques conservateurs, mais également en raison de la dimension clairement identitaire et régionaliste que prend ce conflit dans la capitale mistiana, Arequipa présente sans conteste un terrain privilégié pour analyser les limites, voire les échecs d’une sécularisation en profond décalage avec les aspirations locales.This paper proposes an approachboth local anddiscursive of the tensionsinvolved in the processof secularizationin Peruat the turn of the nineteenth and twentieth centuries,from the case study– bothextreme andrepresentative – of Arequipa.During this period, the press of Arequipais the setting for an intense debateamong liberals, concerned about the entrance of the cityin modern times,and theconservative Catholics and, who see this debate as adirect threatto the traditional political and moral power they hadfor generationsin the region.Because of the violenceof the debates thatopposeliberaland conservative Catholics, but also because of the clear regional and identity dimension of the conflict in themistiana capital, Arequipa is certainly afertile groundfor the analysis ofthe limits,and eventhe failures of the secularizationprocesscompletely out of phase withlocal aspirations.El estudio que proponemos tiene como hilo conductor

  17. Laser-induced plasmas as an analytical source for quantitative analysis of gaseous and aerosol systems: Fundamentals of plasma-particle interactions

    Science.gov (United States)

    Diwakar, Prasoon K.

    2009-11-01

    Laser-induced Breakdown Spectroscopy (LIBS) is a relatively new analytical diagnostic technique which has gained serious attention in recent past due to its simplicity, robustness, and portability and multi-element analysis capabilities. LIBS has been used successfully for analysis of elements in different media including solids, liquids and gases. Since 1963, when the first breakdown study was reported, to 1983, when the first LIBS experiments were reported, the technique has come a long way, but the majority of fundamental understanding of the processes that occur has taken place in last few years, which has propelled LIBS in the direction of being a well established analytical technique. This study, which mostly focuses on LIBS involving aerosols, has been able to unravel some of the mysteries and provide knowledge that will be valuable to LIBS community as a whole. LIBS processes can be broken down to three basic steps, namely, plasma formation, analyte introduction, and plasma-analyte interactions. In this study, these three steps have been investigated in laser-induced plasma, focusing mainly on the plasma-particle interactions. Understanding plasma-particle interactions and the fundamental processes involved is important in advancing laser-induced breakdown spectroscopy as a reliable and accurate analytical technique. Critical understanding of plasma-particle interactions includes study of the plasma evolution, analyte atomization, and the particle dissociation and diffusion. In this dissertation, temporal and spatial studies have been done to understand the fundamentals of the LIBS processes including the breakdown of gases by the laser pulse, plasma inception mechanisms, plasma evolution, analyte introduction and plasma-particle interactions and their influence on LIBS signal. Spectral measurements were performed in a laser-induced plasma and the results reveal localized perturbations in the plasma properties in the vicinity of the analyte species, for

  18. Application of Laser Induced Breakdown Spectroscopy to the identification of emeralds from different synthetic processes

    International Nuclear Information System (INIS)

    Agrosì, G.; Tempesta, G.; Scandale, E.; Legnaioli, S.; Lorenzetti, G.; Pagnotta, S.; Palleschi, V.; Mangone, A.; Lezzerini, M.

    2014-01-01

    Laser Induced Breakdown Spectroscopy can provide a useful contribution in mineralogical field in which the quantitative chemical analyses (including the evaluation of light elements) can play a key role in the studies on the origin of the emeralds. In particular, the chemical analyses permit to determine those trace elements, known as fingerprints, that can be useful to study their provenance. This technique, not requiring sample preparation results particularly suitable for gemstones, that obviously must be studied in a non-destructive way. In this paper, the LIBS technique was applied to distinguish synthetic emeralds grown by Biron hydrothermal method from those grown by Chatham flux method. The analyses performed by collinear double-pulse LIBS give a signal enhancement useful for the quantitative chemical analyses while guaranteeing a minimal sample damage. In this way it was obtained a considerable improvement on the detection limit of the trace elements, whose determination is essential for determining the origin of emerald gemstone. The trace elements V, Cr, and Fe and their relative amounts allowed the correct attribution of the manufacturer. Two different methods for quantitative analyses were used for this study: the standard Calibration-Free LIBS (CF-LIBS) method and its recent evolution, the One Point Calibration LIBS (OPC-LIBS). This is the first approach to the evaluation of the emerald origin by means of the LIBS technique. - Highlights: • A LIBS method for discrimination between synthetic emeralds is presented. • Only one standard of known composition is needed for the analysis. • A set of two kind of synthetic emeralds has been analyzed. • The cromophoric elements Cr, V and Fe amounts have been used to determine the origin of emerald gemstone

  19. Evaluation of the standard normal variate method for Laser-Induced Breakdown Spectroscopy data treatment applied to the discrimination of painting layers

    Science.gov (United States)

    Syvilay, D.; Wilkie-Chancellier, N.; Trichereau, B.; Texier, A.; Martinez, L.; Serfaty, S.; Detalle, V.

    2015-12-01

    Nowadays, Laser-Induced Breakdown Spectroscopy (LIBS) is frequently used for in situ analyses to identify pigments from mural paintings. Nonetheless, in situ analyses require a robust instrumentation in order to face to hard experimental conditions. This may imply variation of fluencies and thus inducing variation of LIBS signal, which degrades spectra and then results. Usually, to overcome these experimental errors, LIBS signal is processed. Signal processing methods most commonly used are the baseline subtraction and the normalization by using a spectral line. However, the latter suggests that this chosen element is a constant component of the material, which may not be the case in paint layers organized in stratigraphic layers. For this reason, it is sometimes difficult to apply this normalization. In this study, another normalization will be carried out to throw off these signal variations. Standard normal variate (SNV) is a normalization designed for these conditions. It is sometimes implemented in Diffuse Reflectance Infrared Fourier Transform Spectroscopy and in Raman Spectroscopy but rarely in LIBS. The SNV transformation is not newly applied on LIBS data, but for the first time the effect of SNV on LIBS spectra was evaluated in details (energy of laser, shot by shot, quantification). The aim of this paper is the quick visualization of the different layers of a stratigraphic painting sample by simple data representations (3D or 2D) after SNV normalization. In this investigation, we showed the potential power of SNV transformation to overcome undesired LIBS signal variations but also its limit of application. This method appears as a promising way to normalize LIBS data, which may be interesting for in-situ depth analyses.

  20. Application of Laser Induced Breakdown Spectroscopy to the identification of emeralds from different synthetic processes

    Energy Technology Data Exchange (ETDEWEB)

    Agrosì, G. [Department of Scienze della Terra e Geoambientali, University of Bari, Bari (Italy); Tempesta, G., E-mail: gioacchino.tempesta@uniba.it [Department of Scienze della Terra e Geoambientali, University of Bari, Bari (Italy); Scandale, E. [Department of Scienze della Terra e Geoambientali, University of Bari, Bari (Italy); Legnaioli, S.; Lorenzetti, G.; Pagnotta, S.; Palleschi, V. [Institute of Chemistry of Organometallic Compounds, CNR, Pisa (Italy); Mangone, A. [Department of Chemistry, University of Bari, Bari (Italy); Lezzerini, M. [Department of Earth Sciences, University of Pisa, Pisa (Italy)

    2014-12-01

    Laser Induced Breakdown Spectroscopy can provide a useful contribution in mineralogical field in which the quantitative chemical analyses (including the evaluation of light elements) can play a key role in the studies on the origin of the emeralds. In particular, the chemical analyses permit to determine those trace elements, known as fingerprints, that can be useful to study their provenance. This technique, not requiring sample preparation results particularly suitable for gemstones, that obviously must be studied in a non-destructive way. In this paper, the LIBS technique was applied to distinguish synthetic emeralds grown by Biron hydrothermal method from those grown by Chatham flux method. The analyses performed by collinear double-pulse LIBS give a signal enhancement useful for the quantitative chemical analyses while guaranteeing a minimal sample damage. In this way it was obtained a considerable improvement on the detection limit of the trace elements, whose determination is essential for determining the origin of emerald gemstone. The trace elements V, Cr, and Fe and their relative amounts allowed the correct attribution of the manufacturer. Two different methods for quantitative analyses were used for this study: the standard Calibration-Free LIBS (CF-LIBS) method and its recent evolution, the One Point Calibration LIBS (OPC-LIBS). This is the first approach to the evaluation of the emerald origin by means of the LIBS technique. - Highlights: • A LIBS method for discrimination between synthetic emeralds is presented. • Only one standard of known composition is needed for the analysis. • A set of two kind of synthetic emeralds has been analyzed. • The cromophoric elements Cr, V and Fe amounts have been used to determine the origin of emerald gemstone.

  1. Constitutive behavior and progressive mechanical failure of electrodes in lithium-ion batteries

    Science.gov (United States)

    Zhang, Chao; Xu, Jun; Cao, Lei; Wu, Zenan; Santhanagopalan, Shriram

    2017-07-01

    The electrodes of lithium-ion batteries (LIB) are known to be brittle and to fail earlier than the separators during an external crush event. Thus, the understanding of mechanical failure mechanism for LIB electrodes (anode and cathode) is critical for the safety design of LIB cells. In this paper, we present experimental and numerical studies on the constitutive behavior and progression of failure in LIB electrodes. Mechanical tests were designed and conducted to evaluate the constitutive properties of porous electrodes. Constitutive models were developed to describe the stress-strain response of electrodes under uniaxial tensile and compressive loads. The failure criterion and a damage model were introduced to model their unique tensile and compressive failure behavior. The failure mechanism of LIB electrodes was studied using the blunt rod test on dry electrodes, and numerical models were built to simulate progressive failure. The different failure processes were examined and analyzed in detail numerically, and correlated with experimentally observed failure phenomena. The test results and models improve our understanding of failure behavior in LIB electrodes, and provide constructive insights on future development of physics-based safety design tools for battery structures under mechanical abuse.

  2. Artificial neural network for on-site quantitative analysis of soils using laser induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    El Haddad, J. [Univ. Bordeaux, LOMA, UMR 5798, F-33400 Talence (France); CNRS, LOMA, UMR 5798, F-33400 Talence (France); Villot-Kadri, M.; Ismaël, A.; Gallou, G. [IVEA Solution, Centre Scientifique d' Orsay, Bât 503, 91400 Orsay (France); Michel, K.; Bruyère, D.; Laperche, V. [BRGM, Service Métrologie, Monitoring et Analyse, 3 avenue Claude Guillemin, B.P 36009, 45060 Orléans Cedex (France); Canioni, L. [Univ. Bordeaux, LOMA, UMR 5798, F-33400 Talence (France); CNRS, LOMA, UMR 5798, F-33400 Talence (France); Bousquet, B., E-mail: bruno.bousquet@u-bordeaux1.fr [Univ. Bordeaux, LOMA, UMR 5798, F-33400 Talence (France); CNRS, LOMA, UMR 5798, F-33400 Talence (France)

    2013-01-01

    Nowadays, due to environmental concerns, fast on-site quantitative analyses of soils are required. Laser induced breakdown spectroscopy is a serious candidate to address this challenge and is especially well suited for multi-elemental analysis of heavy metals. However, saturation and matrix effects prevent from a simple treatment of the LIBS data, namely through a regular calibration curve. This paper details the limits of this approach and consequently emphasizes the advantage of using artificial neural networks well suited for non-linear and multi-variate calibration. This advanced method of data analysis is evaluated in the case of real soil samples and on-site LIBS measurements. The selection of the LIBS data as input data of the network is particularly detailed and finally, resulting errors of prediction lower than 20% for aluminum, calcium, copper and iron demonstrate the good efficiency of the artificial neural networks for on-site quantitative LIBS of soils. - Highlights: ► We perform on-site quantitative LIBS analysis of soil samples. ► We demonstrate that univariate analysis is not convenient. ► We exploit artificial neural networks for LIBS analysis. ► Spectral lines other than the ones from the analyte must be introduced.

  3. Artificial neural network for on-site quantitative analysis of soils using laser induced breakdown spectroscopy

    International Nuclear Information System (INIS)

    El Haddad, J.; Villot-Kadri, M.; Ismaël, A.; Gallou, G.; Michel, K.; Bruyère, D.; Laperche, V.; Canioni, L.; Bousquet, B.

    2013-01-01

    Nowadays, due to environmental concerns, fast on-site quantitative analyses of soils are required. Laser induced breakdown spectroscopy is a serious candidate to address this challenge and is especially well suited for multi-elemental analysis of heavy metals. However, saturation and matrix effects prevent from a simple treatment of the LIBS data, namely through a regular calibration curve. This paper details the limits of this approach and consequently emphasizes the advantage of using artificial neural networks well suited for non-linear and multi-variate calibration. This advanced method of data analysis is evaluated in the case of real soil samples and on-site LIBS measurements. The selection of the LIBS data as input data of the network is particularly detailed and finally, resulting errors of prediction lower than 20% for aluminum, calcium, copper and iron demonstrate the good efficiency of the artificial neural networks for on-site quantitative LIBS of soils. - Highlights: ► We perform on-site quantitative LIBS analysis of soil samples. ► We demonstrate that univariate analysis is not convenient. ► We exploit artificial neural networks for LIBS analysis. ► Spectral lines other than the ones from the analyte must be introduced

  4. Novel approach to recover cobalt and lithium from spent lithium-ion battery using oxalic acid.

    Science.gov (United States)

    Zeng, Xianlai; Li, Jinhui; Shen, Bingyu

    2015-09-15

    With the booming of consumer electronics (CE) and electric vehicle (EV), a large number of spent lithium-ion battery (LIBs) have been generated worldwide. Resource depletion and environmental concern driven from the sustainable industry of CE and EV have motivated spent LIBs should be recovered urgently. However, the conventional process combined with leaching, precipitating, and filtering was quite complicated to recover cobalt and lithium from spent LIBs. In this work, we developed a novel recovery process, only combined with oxalic acid leaching and filtering. When the optimal parameters for leaching process is controlled at 150 min retention time, 95 °C heating temperature, 15 g L(-1) solid-liquid ratio, and 400 rpm rotation rate, the recovery rate of lithium and cobalt from spent LIBs can reach about 98% and 97%, respectively. Additionally, we also tentatively discovered the leaching mechanism of lithium cobalt oxide (LiCoO2) using oxalic acid, and the leaching order of the sampling LiCoO2 of spent LIBs. All the obtained results can contribute to a short-cut and high-efficiency process of spent LIBs recycling toward a sound closed-loop cycle. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Identification of quantum dots labeled metallothionein by fast scanning laser-induced breakdown spectroscopy

    International Nuclear Information System (INIS)

    Konecna, Marie; Novotny, Karel; Krizkova, Sona; Blazkova, Iva; Kopel, Pavel; Kaiser, Jozef; Hodek, Petr; Kizek, Rene

    2014-01-01

    The technique described in this paper allows detection of quantum dots (QDs) specifically deposited on the polystyrene surface by laser-induced breakdown spectroscopy (LIBS). Using LIBS, the distribution of QDs or their conjugates with biomolecules deposited on the surface can be observed, regardless of the fact if they exhibit fluorescence or not. QDs deposited on the specific surface of polystyrene microplate in the form of spots are detected by determination of the metal included in the QDs structure. Cd-containing QDs (CdS, CdTe) stabilized with mercaptopropionic (MPA) or mercaptosuccinic (MSA) acid, respectively, alone or in the form of conjugates with metallothionein (MT) biomolecule are determined by using the 508.58 nm Cd emission line. The observed absolute detection limit for Cd in CdTe QDs conjugates with MT in one spot was 3 ng Cd. Due to the high sensitivity of this technique, the immunoanalysis in combination with LIBS was also investigated. Cd spatial distribution in sandwich immunoassay was detected. - Highlights: • We describe determination of biomolecules labeled with quantum dots by LIBS. • LIBS and immunoassay are applied for the determination of metallothionein. • Metallothionein amount detected by LIBS is 10-times lower compared to ELISA

  6. Identification of quantum dots labeled metallothionein by fast scanning laser-induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Konecna, Marie [Central European Institute of Technology, Brno University of Technology, Technicka 3058/10, CZ-616 00 Brno (Czech Republic); Department of Chemistry and Biochemistry, Faculty of Agronomy, Mendel University in Brno, Zemedelska 1, CZ-613 00 Brno (Czech Republic); Novotny, Karel [Central European Institute of Technology, Masaryk University, Kamenice 753/5, CZ-625 00 Brno (Czech Republic); Krizkova, Sona [Central European Institute of Technology, Brno University of Technology, Technicka 3058/10, CZ-616 00 Brno (Czech Republic); Department of Chemistry and Biochemistry, Faculty of Agronomy, Mendel University in Brno, Zemedelska 1, CZ-613 00 Brno (Czech Republic); Blazkova, Iva [Department of Chemistry and Biochemistry, Faculty of Agronomy, Mendel University in Brno, Zemedelska 1, CZ-613 00 Brno (Czech Republic); Kopel, Pavel [Central European Institute of Technology, Brno University of Technology, Technicka 3058/10, CZ-616 00 Brno (Czech Republic); Department of Chemistry and Biochemistry, Faculty of Agronomy, Mendel University in Brno, Zemedelska 1, CZ-613 00 Brno (Czech Republic); Kaiser, Jozef [Central European Institute of Technology, Brno University of Technology, Technicka 3058/10, CZ-616 00 Brno (Czech Republic); Institute of Physical Engineering, Brno University of Technology, Technicka 2, CZ-616 69 Brno (Czech Republic); Hodek, Petr [Department of Biochemistry, Faculty of Science, Charles University in Prague, Hlavova 2030/8, CZ-128 00 Prague,Czech Republic (Czech Republic); Kizek, Rene [Central European Institute of Technology, Brno University of Technology, Technicka 3058/10, CZ-616 00 Brno (Czech Republic); Department of Chemistry and Biochemistry, Faculty of Agronomy, Mendel University in Brno, Zemedelska 1, CZ-613 00 Brno (Czech Republic); and others

    2014-11-01

    The technique described in this paper allows detection of quantum dots (QDs) specifically deposited on the polystyrene surface by laser-induced breakdown spectroscopy (LIBS). Using LIBS, the distribution of QDs or their conjugates with biomolecules deposited on the surface can be observed, regardless of the fact if they exhibit fluorescence or not. QDs deposited on the specific surface of polystyrene microplate in the form of spots are detected by determination of the metal included in the QDs structure. Cd-containing QDs (CdS, CdTe) stabilized with mercaptopropionic (MPA) or mercaptosuccinic (MSA) acid, respectively, alone or in the form of conjugates with metallothionein (MT) biomolecule are determined by using the 508.58 nm Cd emission line. The observed absolute detection limit for Cd in CdTe QDs conjugates with MT in one spot was 3 ng Cd. Due to the high sensitivity of this technique, the immunoanalysis in combination with LIBS was also investigated. Cd spatial distribution in sandwich immunoassay was detected. - Highlights: • We describe determination of biomolecules labeled with quantum dots by LIBS. • LIBS and immunoassay are applied for the determination of metallothionein. • Metallothionein amount detected by LIBS is 10-times lower compared to ELISA.

  7. Laser-induced breakdown spectroscopy for analysis of plant materials: A review

    International Nuclear Information System (INIS)

    Santos, Dário; Nunes, Lidiane Cristina; Gustinelli Arantes de Carvalho, Gabriel; Gomes, Marcos da Silva; Souza, Paulino Florêncio de; Leme, Flavio de Oliveira; Gustavo Cofani dos Santos, Luis; Krug, Francisco José

    2012-01-01

    Developments and contributions of laser-induced breakdown spectroscopy (LIBS) for the determination of elements in plant materials are reviewed. Several applications where the solid samples are interrogated by simply focusing the laser pulses directly onto a fresh or dried surface of leaves, roots, fruits, vegetables, wood and pollen are presented. For quantitative purposes aiming at plant nutrition diagnosis, the test sample presentation in the form of pressed pellets, prepared from clean, dried and properly ground/homogenized leaves, and the use of univariate or multivariate calibration strategies are revisited. - Highlights: ► Qualitative and quantitative LIBS analysis of plant materials are reviewed. ► Fresh or dried leaves, fruits, roots and pellets can be easily interrogated by LIBS. ► LIBS is a powerful tool for plant nutrition diagnosis and elemental mapping. ► Intended LIBS users will find a survey of applications in a comprehensive table.

  8. Relations between passage rates of rumen fluid and particulate matter and foam production in rumen contents of cattle fed on different diets ad lib.

    Science.gov (United States)

    Okine, E K; Mathison, G W; Hardin, R T

    1989-03-01

    1. A group of six cattle, three of which had a non-bloating history (group A) and had been ruminally cannulated for the previous 2 years, and three with a history of being bloat-prone (group B) and which had been ruminally cannulated only 3 months before the study, were fed ad lib. on chopped lucerne (Medicago sativa) hay, lucerne pellets, or a 100 g chopped hay and 900 g rolled barley grain/kg diet over three periods of 30 d each. Flow of rumen digesta, by reference to CoEDTA and chromium-mordanted fibres, and foam production from samples of rumen contents were measured. 2. Samples of rumen contents (50 ml) from group A produced foam heights of 150 and 60 mm, 2 and 4 h after feeding respectively, compared with 240 and 150 mm for group B (P less than 0.05). 3. The fractional passage rate of the 1-2 mm particles mordanted with Cr did not differ (P greater than 0.05) between groups. 4. The fractional outflow rates (FOR) for CoEDTA 0-2 h and 2-7 h after feed was offered were 0.205 and 0.160/h for group A and 0.093 and 0.086/h for group B respectively (P less than 0.05). 5. Rumen-fluid FOR 0-2 h and 2-7 h after provision of feed were significantly (P less than 0.05) inversely correlated (r -0.74 and -0.85 respectively) with the amount of foam produced from rumen contents at these times.

  9. #HackLibSchool

    Directory of Open Access Journals (Sweden)

    Micah Vandegrift

    2010-10-01

    Full Text Available In the Library with the Lead Pipe welcomes guest poster Micah Vandegrift. Micah is a graduate student in Library and Information Studies at Florida State University. He currently lives in Brooklyn, NY, and is interning at the Brooklyn Public Library. Micah’s education has focused on 20th century American culture, digital media and the humanities and [...

  10. Determination of inorganic nutrients in wheat flour by laser-induced breakdown spectroscopy and energy dispersive X-ray fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Peruchi, Lidiane Cristina; Nunes, Lidiane Cristina; Gustinelli Arantes de Carvalho, Gabriel; Guerra, Marcelo Braga Bueno; Almeida, Eduardo de; Rufini, Iolanda Aparecida [NAPTISA Research Support Center “Technology and Innovation for a Sustainable Agriculture”, Center for Nuclear Energy in Agriculture, University of São Paulo, Av. Centenário 303, 13416-000, Piracicaba SP (Brazil); Santos, Dário [Federal University of São Paulo, R. Prof. Artur Riedel 275, 09972-270, Diadema SP (Brazil); Krug, Francisco José, E-mail: fjkrug@cena.usp.br [NAPTISA Research Support Center “Technology and Innovation for a Sustainable Agriculture”, Center for Nuclear Energy in Agriculture, University of São Paulo, Av. Centenário 303, 13416-000, Piracicaba SP (Brazil)

    2014-10-01

    Laser-induced breakdown spectroscopy (LIBS) and energy dispersive X-ray fluorescence spectrometry (EDXRF) were evaluated for the determination of P, K, Ca, Mg, S, Fe, Cu, Mn and Zn in pressed pellets of wheat flours. EDXRF and LIBS calibration models were built with analytes mass fractions determined by inductively coupled plasma optical emission spectrometry after microwave-assisted acid digestion in a set of 25 wheat flour laboratory samples. Test samples consisted of pressed pellets prepared from wheat flour mixed with 30% mm{sup −1} cellulose binder. Experiments were carried out with a LIBS setup consisted of a Q-switched Nd:YAG laser and a spectrometer with Echelle optics and ICCD, and a benchtop EDXRF system fitted with a Rh target X-ray tube and a Si(Li) semiconductor detector. The correlation coefficients from the linear calibration models of P, K, Ca, Mg, S, Fe, Mn and Zn determined by LIBS and/or EDXRF varied from 0.9705 for Zn to 0.9990 for Mg by LIBS, and from 0.9306 for S to 0.9974 for K by EDXRF. The coefficients of variation of measurements varied from 1.2 to 20% for LIBS, and from 0.3 to 24% for EDXRF. The predictive capabilities based on RMSEP (root mean square error of prediction) values were appropriate for the determination of P, Ca, Mg, Fe, Mn and Zn by LIBS, and for P, K, S, Ca, Fe, and Zn by EDXRF. In general, results from the analysis of NIST SRM 1567a Wheat flour by LIBS and EDXRF were in agreement with their certified mass fractions. - Highlights: • Combination of LIBS and EDXRF for quantitative analysis of wheat flour. • Validation performed for determination of P, K, Ca, Mg, S, Fe, Cu, Mn and Zn. • Same test samples can be used for both methods. • Appropriate limits of detection for all tested analytes. • Methods are simple and provide fast and accurate results for routine analysis.

  11. An artificial neural network approach to laser-induced breakdown spectroscopy quantitative analysis

    International Nuclear Information System (INIS)

    D’Andrea, Eleonora; Pagnotta, Stefano; Grifoni, Emanuela; Lorenzetti, Giulia; Legnaioli, Stefano; Palleschi, Vincenzo; Lazzerini, Beatrice

    2014-01-01

    The usual approach to laser-induced breakdown spectroscopy (LIBS) quantitative analysis is based on the use of calibration curves, suitably built using appropriate reference standards. More recently, statistical methods relying on the principles of artificial neural networks (ANN) are increasingly used. However, ANN analysis is often used as a ‘black box’ system and the peculiarities of the LIBS spectra are not exploited fully. An a priori exploration of the raw data contained in the LIBS spectra, carried out by a neural network to learn what are the significant areas of the spectrum to be used for a subsequent neural network delegated to the calibration, is able to throw light upon important information initially unknown, although already contained within the spectrum. This communication will demonstrate that an approach based on neural networks specially taylored for dealing with LIBS spectra would provide a viable, fast and robust method for LIBS quantitative analysis. This would allow the use of a relatively limited number of reference samples for the training of the network, with respect to the current approaches, and provide a fully automatizable approach for the analysis of a large number of samples. - Highlights: • A methodological approach to neural network analysis of LIBS spectra is proposed. • The architecture of the network and the number of inputs are optimized. • The method is tested on bronze samples already analyzed using a calibration-free LIBS approach. • The results are validated, compared and discussed

  12. Double-pulse laser-induced breakdown spectroscopy analysis of scales from petroleum pipelines

    International Nuclear Information System (INIS)

    o – CEP 24210-346 – Niterói, Rio de Janeiro (Brazil))" data-affiliation=" (Physics Department of University Federal Fluminense, Av. Gal. Milton Tavares de Souza, s/no – CEP 24210-346 – Niterói, Rio de Janeiro (Brazil))" >Cavalcanti, G.H.; Rocha, A.A.; Damasceno, R.N.; Legnaioli, S.; Lorenzetti, G.; Pardini, L.; Palleschi, V.

    2013-01-01

    Pipeline scales from the Campos Bay Petroleum Field near Rio de Janeiro, Brazil have been analyzed by both Raman spectroscopy and by laser-induced breakdown spectroscopy (LIBS) using a double-pulse, calibration-free approach. Elements that are characteristic of petroleum (e.g. C, H, N, O, Mg, Na, Fe and V) were detected, in addition to the Ca, Al, and Si which form the matrix of the scale. The LIBS results were compared with the results of micro-Raman spectroscopy, which confirmed the nature of the incrustations inferred by the LIBS analysis. Results of this preliminary study suggest that diffusion of pipe material into the pipeline intake column plays an important role in the growth of scale. Thanks to the simplicity and relative low cost of equipment and to the fact that no special chemical pre-treatment of the samples is needed, LIBS can offer very fast acquisition of data and the possibility of in situ measurements. LIBS could thus represent an alternative or complementary method for the chemical characterization of the scales by comparison to conventional analytical techniques, such as X-ray diffraction or X-ray fluorescence. - Highlights: • Samples of scales from petroleum pipelines were analyzed using double pulse LIBS. • LIBS is proposed as an alternative method to conventional analytical techniques. • The scale growth is influenced by the product of corrosion in the column of production. • The diffusion of pipe material into the inlay is important for the growth of scale

  13. Fungi isolated from phyllosphere of fodder galega (Galega orientalis

    Directory of Open Access Journals (Sweden)

    Bożena Cwalina-Ambrozik

    2013-12-01

    Full Text Available The object of the experiment was fodder galega (Galega orientalis Lam. cultivated in 2001-2003 as field crop on three plots: 1. without fertilization, 2. 40 kg P2O5 × ha-1 and 80 kg K2O × ha-1, 3. 80 kg P2O5 × ha-1 and 160 kg K2O × ha-1. During the dry and warm vegetation season of 2002 almost two times fewer isolates were obtained from the leaves than in 2003 that was the most abundant in fungi. Yeasts-like fungi (30% of the total number of isolates and saprotrophic fungi with dominated species: Acremonium strictum (8.5%, genus Epicoccum (7.8%, Humicola (9.5% and Penicillium (18.9% were the fungi most frequently populating the leaves of galega. The share of pathogens in the total number of isolates obtained from the phyllosphere was 10.6%. They were represented by fungi of Ascochyta spp., Botrytis cinerea, genus Fusarium, Phoma medicaginis and Sclerotinia sclerotiorum. Reduction by 1.9 to 4.6% in the number of fungi isolated from the phyllosphere of galega without fertilization as compared to galega cultivated in combinations with fertilization was recorded. Generally, the smallest number of pathogens was recovered from galega fertilized with 40 kg P2O5 × ha-1 and 80 kg K2O × ha-1. B. cinerea most frequently populated galega in combination without fertilization, genus Fusarium fungi in combination without fertilization and with fertilization with 80 kg P2O5 × ha-1 and 160 kg K2O × ha-1, while Ascochyta spp. were isolated from galega with fertilization only.

  14. Comprehensive particle characterization of modern gasoline and diesel passenger cars at low ambient temperatures

    Science.gov (United States)

    Mathis, Urs; Mohr, Martin; Forss, Anna-Maria

    Particle measurements were performed in the exhaust of five light-duty vehicles (Euro-3) at +23, -7, and -20 °C ambient temperatures. The characterization included measurements of particle number, active surface area, number size distribution, and mass size distribution. We investigated two port-injection spark-ignition (PISI) vehicles, a direct-injection spark-ignition (DISI) vehicle, a compressed ignition (CI) vehicle with diesel particle filter (DPF), and a CI vehicle without DPF. To minimize sampling effects, particles were directly sampled from the tailpipe with a novel porous tube diluter at controlled sampling parameters. The diluted exhaust was split into two branches to measure either all or only non-volatile particles. Effect of ambient temperature was investigated on particle emission for cold and warmed-up engine. For the gasoline vehicles and the CI vehicle with DPF, the main portion of particle emission was found in the first minutes of the driving cycle at cold engine start. The particle emission of the CI vehicle without DPF was hardly affected by cold engine start. For the PISI vehicles, particle number emissions were superproportionally increased in the diameter size range from 0.1 to 0.3 μm during cold start at low ambient temperature. Based on the particle mass size distribution, the DPF removed smaller particles ( dpefficiently than larger particles ( dp>0.5μm). No significant effect of ambient temperature was observed when the engine was warmed up. Peak emission of volatile nanoparticles only took place at specific conditions and was poorly repeatable. Nucleation of particles was predominately observed during or after strong acceleration at high speed and during regeneration of the DPF.

  15. Assessment of statistical uncertainty in the quantitative analysis of solid samples in motion using laser-induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Cabalin, L.M.; Gonzalez, A. [Department of Analytical Chemistry, University of Malaga, E-29071 Malaga (Spain); Ruiz, J. [Department of Applied Physics I, University of Malaga, E-29071 Malaga (Spain); Laserna, J.J., E-mail: laserna@uma.e [Department of Analytical Chemistry, University of Malaga, E-29071 Malaga (Spain)

    2010-08-15

    Statistical uncertainty in the quantitative analysis of solid samples in motion by laser-induced breakdown spectroscopy (LIBS) has been assessed. For this purpose, a LIBS demonstrator was designed and constructed in our laboratory. The LIBS system consisted of a laboratory-scale conveyor belt, a compact optical module and a Nd:YAG laser operating at 532 nm. The speed of the conveyor belt was variable and could be adjusted up to a maximum speed of 2 m s{sup -1}. Statistical uncertainty in the analytical measurements was estimated in terms of precision (reproducibility and repeatability) and accuracy. The results obtained by LIBS on shredded scrap samples under real conditions have demonstrated that the analytical precision and accuracy of LIBS is dependent on the sample geometry, position on the conveyor belt and surface cleanliness. Flat, relatively clean scrap samples exhibited acceptable reproducibility and repeatability; by contrast, samples with an irregular shape or a dirty surface exhibited a poor relative standard deviation.

  16. Application of a compact diode pumped solid-state laser source for quantitative laser-induced breakdown spectroscopy analysis of steel

    Science.gov (United States)

    Tortschanoff, Andreas; Baumgart, Marcus; Kroupa, Gerhard

    2017-12-01

    Laser-induced breakdown spectroscopy (LIBS) technology holds the potential for onsite real-time measurements of steel products. However, for a mobile and robust LIBS measurement system, an adequate small and ruggedized laser source is a key requirement. In this contribution, we present tests with our compact high-power laser source, which, initially, was developed for ignition applications. The CTR HiPoLas® laser is a robust diode pumped solid-state laser with a passive Q-switch with dimensions of less than 10 cm3. The laser generates 2.5-ns pulses with 30 mJ at a maximum continuous repetition rate of about 30 Hz. Feasibility of LIBS experiments with the laser source was experimentally verified with steel samples. The results show that the laser with its current optical output parameters is very well-suited for LIBS measurements. We believe that the miniaturized laser presented here will enable very compact and robust portable high-performance LIBS systems.

  17. Assessment of statistical uncertainty in the quantitative analysis of solid samples in motion using laser-induced breakdown spectroscopy

    Science.gov (United States)

    Cabalín, L. M.; González, A.; Ruiz, J.; Laserna, J. J.

    2010-08-01

    Statistical uncertainty in the quantitative analysis of solid samples in motion by laser-induced breakdown spectroscopy (LIBS) has been assessed. For this purpose, a LIBS demonstrator was designed and constructed in our laboratory. The LIBS system consisted of a laboratory-scale conveyor belt, a compact optical module and a Nd:YAG laser operating at 532 nm. The speed of the conveyor belt was variable and could be adjusted up to a maximum speed of 2 m s - 1 . Statistical uncertainty in the analytical measurements was estimated in terms of precision (reproducibility and repeatability) and accuracy. The results obtained by LIBS on shredded scrap samples under real conditions have demonstrated that the analytical precision and accuracy of LIBS is dependent on the sample geometry, position on the conveyor belt and surface cleanliness. Flat, relatively clean scrap samples exhibited acceptable reproducibility and repeatability; by contrast, samples with an irregular shape or a dirty surface exhibited a poor relative standard deviation.

  18. Assessment of statistical uncertainty in the quantitative analysis of solid samples in motion using laser-induced breakdown spectroscopy

    International Nuclear Information System (INIS)

    Cabalin, L.M.; Gonzalez, A.; Ruiz, J.; Laserna, J.J.

    2010-01-01

    Statistical uncertainty in the quantitative analysis of solid samples in motion by laser-induced breakdown spectroscopy (LIBS) has been assessed. For this purpose, a LIBS demonstrator was designed and constructed in our laboratory. The LIBS system consisted of a laboratory-scale conveyor belt, a compact optical module and a Nd:YAG laser operating at 532 nm. The speed of the conveyor belt was variable and could be adjusted up to a maximum speed of 2 m s -1 . Statistical uncertainty in the analytical measurements was estimated in terms of precision (reproducibility and repeatability) and accuracy. The results obtained by LIBS on shredded scrap samples under real conditions have demonstrated that the analytical precision and accuracy of LIBS is dependent on the sample geometry, position on the conveyor belt and surface cleanliness. Flat, relatively clean scrap samples exhibited acceptable reproducibility and repeatability; by contrast, samples with an irregular shape or a dirty surface exhibited a poor relative standard deviation.

  19. Three-dimensional free-standing carbon nanotubes for a flexible lithium-ion battery anode

    International Nuclear Information System (INIS)

    Kang, Chiwon; Cha, Eunho; Baskaran, Rangasamy; Choi, Wonbong

    2016-01-01

    Flexible lithium-ion batteries (LIBs) have received considerable attention as energy sources for wearable electronics. In recent years, much effort has been devoted to study light-weight, robust, and flexible electrodes. However, high areal and volumetric capacities need to be achieved for practical power and energy densities. In this paper, we report the use of three-dimensional (3D) free-standing carbon nanotubes (CNTs) as a current collector-free anode to demonstrate flexible LIBs with enhanced areal and volumetric capacities. High density CNTs grown on copper (Cu) mesh are transferred to a flexible graphene/polyethylene terephthalate  film and integrated into a flexible LIB. A fully flexible LIB cell integrated with the 3D CNT anode delivers a high areal capacity of 0.25 mAh cm"−"2 at 0.1C and shows fairly consistent open circuit voltage under bending. These findings may provide significant advances in the application of flexible LIB based electronic devices. (paper)

  20. Flexible phosphorus doped carbon nanosheets/nanofibers: Electrospun preparation and enhanced Li-storage properties as free-standing anodes for lithium ion batteries

    Science.gov (United States)

    Li, Desheng; Wang, Dongya; Rui, Kun; Ma, Zhongyuan; Xie, Ling; Liu, Jinhua; Zhang, Yu; Chen, Runfeng; Yan, Yan; Lin, Huijuan; Xie, Xiaoji; Zhu, Jixin; Huang, Wei

    2018-04-01

    The emerging wearable and foldable electronic devices drive the development of flexible lithium ion batteries (LIBs). Carbon materials are considered as one of the most promising electrode materials for LIBs due to their light weight, low cost and good structural stability against repeated deformations. However, the specific capacity, rate capability and long-term cycling performance still need to be improved for their applications in next-generation LIBs. Herein, we report a facile approach for immobilizing phosphorus into a large-area carbon nanosheets/nanofibers interwoven free-standing paper for LIBs. As an anode material for LIBs, it shows high reversible capacity of 1100 mAh g-1 at a current density of 200 mA g-1, excellent rate capabilities (e.g., 200 mAh g-1 at 20,000 mA g-1). Even at a high current density of 1000 mA g-1, it still maintains a superior specific capacity of 607 mAh g-1 without obvious decay.