WorldWideScience

Sample records for ascending aortic pseudoaneurysm

  1. Combined Repair of Ascending Aortic Pseudoaneurysm and Abdominal Aortic Aneurysm in a Patient with Marfan Syndrome

    OpenAIRE

    Kokotsakis, John N.; Lioulias, Achilleas G.; Foroulis, Christophoros N.; Skouteli, Eleni Anna T.; Milonakis, Michael K.; Bastounis, Elias A.; Boulafendis, Dimitrios G.

    2003-01-01

    Pseudoaneurysms of the ascending aorta after the original inclusion/wrap technique of the Bentall procedure present a difficult surgical management problem and are associated with substantial morbidity and mortality. Patients with Marfan syndrome frequently develop aneurysms and dissections that involve multiple aortic segments. We present the case of a Marfan patient who successfully underwent repair of a giant ascending aortic pseudoaneurysm and concomitant repair of an abdominal aortic ane...

  2. Surgical repair of a pseudoaneurysm of the ascending aorta after aortic valve replacement

    Directory of Open Access Journals (Sweden)

    Almeida Rui Manuel Sequeira de

    2001-01-01

    Full Text Available We report the case of a patient with a pseudoaneurysm of the ascending aortic clinically diagnosed 5 months after surgical replacement of the aortic valve. Diagnosis was confirmed with the aid of two-dimensional echocardiography and helicoidal angiotomography. The corrective surgery, which consisted of a reinforced suture of the communication with the ascending aorta after opening and aspiration of the cavity of the pseudoaneurysm, was successfully performed through a complete sternotomy using extracorporeal circulation, femorofemoral cannulation, and moderate hypothermia, with no aortic clamping.

  3. Combined Repair of Ascending Aortic Pseudoaneurysm and Abdominal Aortic Aneurysm in a Patient with Marfan Syndrome

    Science.gov (United States)

    Kokotsakis, John N.; Lioulias, Achilleas G.; Foroulis, Christophoros N.; Skouteli, Eleni Anna T.; Milonakis, Michael K.; Bastounis, Elias A.; Boulafendis, Dimitrios G.

    2003-01-01

    Pseudoaneurysms of the ascending aorta after the original inclusion/wrap technique of the Bentall procedure present a difficult surgical management problem and are associated with substantial morbidity and mortality. Patients with Marfan syndrome frequently develop aneurysms and dissections that involve multiple aortic segments. We present the case of a Marfan patient who successfully underwent repair of a giant ascending aortic pseudoaneurysm and concomitant repair of an abdominal aortic aneurysm. An aggressive surgical strategy followed by life-long cardiovascular monitoring is warranted in order to prolong the survival of these patients. (Tex Heart Inst J 2003;30:233–5) PMID:12959210

  4. Endovascular approach to treat ascending aortic pseudoaneurysm in a patient with previous CABG and very high surgical risk.

    Science.gov (United States)

    Zago, Alexandre C; Saadi, Eduardo K; Zago, Alcides J

    2011-10-01

    Pseudoaneurysm of the ascending aorta is an uncommon pathology and a challenge in high-risk patients who undergo conventional surgery because of high operative morbidity and mortality. Endovascular exclusion of an aortic pseudoaneurysm using an endoprosthesis is a less invasive approach, but few such cases have been reported. Moreover, the use of this approach poses unique therapeutic challenges because there is no specific endoprosthesis for ascending aortic repair, particularly to treat patients with previous coronary artery bypass graft (CABG). We describe the case of a 74-year-old patient who had undergone CABG and later presented with an iatrogenic ascending aortic pseudoaneurysm that occurred during an angiography. This patient was at very high risk for surgical treatment and, therefore, an endovascular approach was adopted: percutaneous coronary intervention for the left main coronary artery, left anterior descending and left circumflex native coronary arteries followed by endovascular endoprosthesis deployment in the ascending aorta to exclude the pseudoaneurysm. Both procedures were successfully performed, and the patient was discharged without complications 4 days later. At 5 months' clinical follow-up, his clinical condition was good and he had no complications. Copyright © 2011 Wiley-Liss, Inc.

  5. Does three-dimensional transesophageal echocardiography provide incremental value in percutaneous closure of ascending aortic pseudoaneurysm?

    Science.gov (United States)

    Elkaryoni, Ahmed; Hsiung, Ming C; Arisha, Mohammed J; Ahmad, Amier; Nanda, Navin C; Mohamed, Ahmed H; Attia, Doaa; Sachdeva, Ankush; Singh, Lovepreet; Yin, Wei-Hsian

    2017-07-01

    Ascending aortic pseudoaneurysms (AO PSAs), if left untreated, are complicated by a high rate of rupture resulting in significant morbidity and mortality. New transcatheter modalities have emerged as acceptable surgical alternatives for their management. We present a case of an ascending aortic PSA in which intraoperative two- and three-dimensional transesophageal echocardiography (2DTEE and 3DTEE) provided a comprehensive assessment of the PSA in pre- and postclosure settings. © 2017, Wiley Periodicals, Inc.

  6. Surgical exclusion of postsurgical pseudoaneurysm of the ascending aorta

    Energy Technology Data Exchange (ETDEWEB)

    Barik, Ramachandra; Patnaik, Amar Narayana [Department of Cardiology, Nizam' s Institute of Medical Sciences, Hyderabad, Andhra Pradesh (India); Kumar, Ravintula Venkata; Mohapatra, Rudra Prasad [Department of Cardiothoracic Surgery, Nizam' s Institute of Medical Sciences, Hyderabad, Andhra Pradesh (India); Medep, Vikas; Nemani, Lalita [Department of Cardiology, Nizam' s Institute of Medical Sciences, Hyderabad, Andhra Pradesh (India)

    2014-01-01

    Pseudoaneurysm of ascending aorta after cardiac surgery is rare in children. We report a case of successful surgical exclusion of ascending aortic pseudoaneurysm in a 15-year-old boy. The neck of the aneurysm was in close proximity to the right coronary artery (RCA)

  7. Surgical exclusion of postsurgical pseudoaneurysm of the ascending aorta

    Science.gov (United States)

    Barik, Ramachandra; Patnaik, Amar Narayana; Kumar, Ravintula Venkata; Mohapatra, Rudra Prasad; Medep, Vikas; Nemani, Lalita

    2014-01-01

    Pseudoaneurysm of ascending aorta after cardiac surgery is rare in children. We report a case of successful surgical exclusion of ascending aortic pseudoaneurysm in a 15-year-old boy. The neck of the aneurysm was in close proximity to the right coronary artery (RCA). PMID:24987261

  8. Surgical exclusion of postsurgical pseudoaneurysm of the ascending aorta

    Directory of Open Access Journals (Sweden)

    Ramachandra Barik

    2014-01-01

    Full Text Available Pseudoaneurysm of ascending aorta after cardiac surgery is rare in children. We report a case of successful surgical exclusion of ascending aortic pseudoaneurysm in a 15-year-old boy. The neck of the aneurysm was in close proximity to the right coronary artery (RCA.

  9. Device occlusion of pseudoaneurysm of ascending aorta

    International Nuclear Information System (INIS)

    Agarwal, Mridul; Ray, Mili; Pallavi, M; Sen, Supratim; Ganguly, Debosree; Joshi, Pankaj; Tanti, Sanjay; Chattopadhyay, Amitabh; Bandyopadhyay, Biswajit

    2011-01-01

    Pseudoaneurysm of ascending aorta is an infrequent but well-recognized and potentially fatal complication after cardiac surgeries. The complication can develop early, delayed or late, and the presentation is also varied. We are presenting here two cases of pseudoaneurysm of ascending aorta following cardiac surgery that were successfully managed by the transcatheter method. The first one occurred following coronary artery bypass surgery and the second one occurred following double-valve replacement surgery. The aortic openings of these aneurysms were occluded with 12 mm and 10 mm atrial septal occluders, respectively, with a good outcome. An immediate postprocedure angiogram showed no residual flow into the sac. Six months of follow-up of both cases also showed excellent results

  10. Surgery for pseudoaneurysm of the ascending aorta under moderate hypothermia

    Directory of Open Access Journals (Sweden)

    Lee Dong-Hyup

    2011-09-01

    Full Text Available Abstract Pseudoaneurysm of the ascending aorta is a rare complication after cardiac surgery. Particularly, pseudoaneurysm due to postoperative infection in the ascending aorta requires surgical treatment with antibiotics. If a large sized pseudoaneurysm is located at the retrosternal space, then there is a very high risk of massive bleeding from rupture during performance of resternotomy. To avoid this risk, we performed femoro-femoral bypass under moderate hypothermia with transient circulatory arrest, and we report here on the successful result of this case.

  11. Wall stress on ascending thoracic aortic aneurysms with bicuspid compared with tricuspid aortic valve.

    Science.gov (United States)

    Xuan, Yue; Wang, Zhongjie; Liu, Raymond; Haraldsson, Henrik; Hope, Michael D; Saloner, David A; Guccione, Julius M; Ge, Liang; Tseng, Elaine

    2018-03-08

    Guidelines for repair of bicuspid aortic valve-associated ascending thoracic aortic aneurysms have been changing, most recently to the same criteria as tricuspid aortic valve-ascending thoracic aortic aneurysms. Rupture/dissection occurs when wall stress exceeds wall strength. Recent studies suggest similar strength of bicuspid aortic valve versus tricuspid aortic valve-ascending thoracic aortic aneurysms; thus, comparative wall stress may better predict dissection in bicuspid aortic valve versus tricuspid aortic valve-ascending thoracic aortic aneurysms. Our aim was to determine whether bicuspid aortic valve-ascending thoracic aortic aneurysms had higher wall stresses than their tricuspid aortic valve counterparts. Patients with bicuspid aortic valve- and tricuspid aortic valve-ascending thoracic aortic aneurysms (bicuspid aortic valve = 17, tricuspid aortic valve = 19) greater than 4.5 cm underwent electrocardiogram-gated computed tomography angiography. Patient-specific 3-dimensional geometry was reconstructed and loaded to systemic pressure after accounting for prestress geometry. Finite element analyses were performed using the LS-DYNA solver (LSTC Inc, Livermore, Calif) with user-defined fiber-embedded material model to determine ascending thoracic aortic aneurysm wall stress. Bicuspid aortic valve-ascending thoracic aortic aneurysms 99th-percentile longitudinal stresses were 280 kPa versus 242 kPa (P = .028) for tricuspid aortic valve-ascending thoracic aortic aneurysms in systole. These stresses did not correlate to diameter for bicuspid aortic valve-ascending thoracic aortic aneurysms (r = -0.004) but had better correlation to tricuspid aortic valve-ascending thoracic aortic aneurysms diameter (r = 0.677). Longitudinal stresses on sinotubular junction were significantly higher in bicuspid aortic valve-ascending thoracic aortic aneurysms than in tricuspid aortic valve-ascending thoracic aortic aneurysms (405 vs 329 kPa, P = .023). Bicuspid

  12. A rare cause of lomber pain: diopatic abdominal aortic pseudoaneurysm

    International Nuclear Information System (INIS)

    Colak, F.; Saglam, M.; Sahin, M.; Bozlar, U.

    2012-01-01

    Full text: Introduction: Abdominal aortic pseudoaneurysms are rare and life-threatening situations. Trauma and operative procedures are common causes of pseudoaneurysm. Abdominal pain is the most common symptom of them. They are usually detected incidentally. Objectives and tasks: We aim to present CTA findings of abdominal aortic pseudoaneurysm causes gradually increasing lomber pain in 70-year-old female patient. Physical examination also made diagnosis easy because of pulsatile mass detected. Materials and methods: Lomber MRG and endoscopic procedures were normal. Then we performed CTA to find the cause for pulsatile mass. Results: Pseudoaneurysm with approximately 6 x 7.5 cm size was compressing duodenum and not showing extravasation at the infrarenal segment of abdominal aorta detected in CTA. Pseudoaneurysm was filling from aorta through a 2 cm neck. Conclusion: Primary cause for pseudoaneurysms is traumating injuries. Initial presentation may be abdominal pain, gastrointestinal bleeding or pulsatile mass. To plan treatment and figure out pseudoaneurysm CTA is very fast and non-invasive technic

  13. Ascending aortic injuries following blunt trauma.

    Science.gov (United States)

    Sun, Xiumei; Hong, Jenny; Lowery, Robert; Goldstein, Steven; Wang, Zuyue; Lindsay, Joseph; Hill, Peter C; Corso, Paul J

    2013-11-01

    The diagnosis and the management of traumatic thoracic aortic injuries have undergone significant changes due to new technology and improved prehospital care. Most of the discussions have focused on descending aortic injuries. In this review, we discuss the recent management of ascending aortic injuries. We found 5 cohort studies on traumatic aortic injuries and 11 case reports describing ascending aortic injuries between 1998 to the present through Medline research. Among case reports, 78.9% of cases were caused by motor vehicle accidents (MVA). 42.1% of patients underwent emergent open repair and the operative mortality was 12.5%. 36.8% underwent delayed repair. Associated injuries occurred in 84.2% of patients. Aortic valve injury was concurrent in 26.3% of patients. The incidence of ascending aortic injury ranged 1.9-20% in cohort studies. Traumatic injuries to the ascending aorta are relatively uncommon among survivors following blunt trauma. Aortography has been replaced by computed tomography and echocardiography as a diagnostic tool. Open repair, either emergent or delayed, remains the treatment of choice. © 2013 Wiley Periodicals, Inc.

  14. Endovascular treatment of thoracic aortic pseudoaneurysm due to brucellosis: a rare case report.

    Science.gov (United States)

    Wang, Shuai; Wang, Qi; Liu, Han; Sun, Siqiao; Sun, Xiwei; Zhang, Yang; Wang, Zhongying; Cheng, Zhihua

    2017-06-02

    Arterial damage is a known complication of brucellosis, but the occurrence of a thoracic aortic pseudoaneurysm secondary to brucellosis has not been previously reported. A 65-year-old Chinese man presented with a pseudoaneurysm in the descending segment of the thoracic aorta that caused symptoms of chest pain and intermittent fever. He was diagnosed with a thoracic aortic pseudoaneurysm secondary to brucellosis based on a positive brucella serology test (standard-tube agglutination test) and imaging examination (computed tomography angiography). Anti-brucellosis treatment and covered stent graft implantation were attempted to eliminate the brucellosis and pseudoaneurysm, respectively, and were ultimately successful, with no symptoms after 6 months of follow-up. Endovascular repair may be effective and safe for treating a thoracic aortic pseudoaneurysm resulting from brucellosis.

  15. Early results of valve-sparing ascending aortic replacement in type A aortic dissection and aortic insufficiency

    Directory of Open Access Journals (Sweden)

    М. Л. Гордеев

    2016-08-01

    Full Text Available Aim: The study was designed to investigate predictors of effective valve-sparing ascending aortic replacement in patients with Stanford type A aortic dissection combined with aortic insufficiency and to analyze efficacy and safety of this kind of surgery.Methods: From January 2010 to December 2015, 49 patients with Stanford type A aortic dissection combined with aortic insufficiency underwent ascending aortic replacement. All patients were divided into 3 groups: valve-sparing procedures (group 1, n = 11, combined aortic valve and supracoronary ascending aortic replacement (group 2, n = 12, and Bentall procedure (group 3, n = 26. We assessed the initial status of patients, incidence of complications and efficacy of valve-sparing ascending aortic replacement.Results: The hospital mortality rate was 8.2% (4/49 patients. The amount of surgical correction correlated with the initial diameter of the aorta at the level of the sinuses of Valsalva. During the hospital period, none of patients from group 1 developed aortic insufficiency exceeding Grade 2 and the vast majority of patients had trivial aortic regurgitation. The parameters of cardiopulmonary bypass, cross-clamp time and circulatory arrest time did not correlate with the initial size of the ascending aorta and aortic valve blood flow impairment, neither did they influence significantly the incidence and severity of neurological complications. The baseline size of the ascending aorta and degree of aortic regurgitation did not impact the course of the early hospital period.Conclusions: Supracoronary ascending aortic replacement combined with aortic valve repair in ascending aortic dissection and aortic regurgitation is effective and safe. The initial size of the ascending aorta and aortic arch do not influence immediate results. The diameter of the aorta at the level of the sinuses of Valsalva and the condition of aortic valve leaflets could be considered as the limiting factors. Further long

  16. Infrarenal Abdominal Aortic Pseudoaneurysm: Is It a Real Emergency?

    Science.gov (United States)

    Massara, Mafalda; Prunella, Roberto; Gerardi, Pasquale; Lillo, Antonio; De Caridi, Giovanni; Serra, Raffaele; Notarstefano, Stefano; Impedovo, Giovanni

    2017-01-01

    Abdominal aortic pseudoaneurysm is a rare but life-threatening condition that occurs due to penetrating or blunt trauma. Clinical manifestations are variable, and the time interval from the initial trauma to diagnosis is variable. A prompt diagnosis and an aggressive management approach are required to avoid catastrophic complications. Possible treatment options are open surgical repair, endovascular repair, pseudoanerysmal sac thrombosis induction through direct thrombin injection, and coil embolization. Here, we present the case of a 75-year-old man affected by an infrarenal abdominal aortic pseudoaneurysm presenting with abdominal and lumbar pain for 3 days, who was successfully treated with an endograft. PMID:29515707

  17. Left Ventricular Assist Device Implantation with Concomitant Aortic Valve and Ascending Aortic Replacement.

    Science.gov (United States)

    Huenges, Katharina; Panholzer, Bernd; Cremer, Jochen; Haneya, Assad

    2018-01-01

    Left ventricular assist device (LVAD) is nowadays a routine therapy for patients with advanced heart failure. We present the case of a 74-year-old male patient who was admitted to our center with terminal heart failure in dilated cardiomyopathy and ascending aortic aneurysm with aortic valve regurgitation. The LVAD implantation with simultaneous aortic valve and supracoronary ascending aortic replacement was successfully performed.

  18. Delayed Presentation of a Giant Ascending Aortic Aneurysm following Aortic Valve Replacement

    Directory of Open Access Journals (Sweden)

    Tugrul Göncü

    2009-01-01

    Full Text Available Giant ascending aortic aneurysm formation following aortic valve replacement is rare. A 28-year-old man who underwent aortic valve replacement with a prosthetic valve for aortic regurgitation secondary to congenital bicuspid aortic valve about 10 years ago was diagnosed with a giant ascending aortic aneurysm about 16 cm in diameter in follow-up. The aneurysm was resected leaving the functional old mechanical prosthesis in place and implanted a 34-mm Hemashield woven graft, associated with the left and right coronary artery button implantation. Histological findings of the aortic aneurysm wall showed cystic medial necrosis. The postoperative course was uneventful and postoperative examination demonstrated good surgical results.

  19. Aorto-right atrial fistula after ascending aortic replacement or aortic value replacement

    International Nuclear Information System (INIS)

    Zhi Aihua; Dai Ruping; Jiang Shiliang; Lu Bin

    2012-01-01

    Objective: To evaluate the CT features of aorto-right atrial fistula after aortic valve replacement (AVR) or ascending aortic replacement. Methods: Eighty-seven patients with aortic-right atrial fistula underwent CT after operation. The CT features were retrospectively analyzed. Fistula was measured according to maximum width of the shunt. Results: Aorto-right atrial fistula was detected in 87 patients after aortic valve replacement or ascending aortic replacement by CT scan. Among them, 25 patients were diagnosed as mild aorto-right atrial fistula, 47 patients as moderate, and 15 patients as severe. Thirty-seven patients underwent follow-up CT.Among them, 10 patients with mild to moderate aorto-right atrial fistula were considered to have complete regression, 8 patients with mild aorto-right atrial fistula considered to have incomplete regression, 14 patients with mild to moderate aorto-right atrial fistula considered to have stable condition, and 5 patients with moderate aorto-right atrial fistula considered to have progression at the 3-month follow-up. Conclusion: CT is a useful tool for defining aorto-right atrial fistula after AVR or ascending aortic replacement and for evaluating it in follow-up. (authors)

  20. Delayed recurrent nerve paralysis following post-traumatic aortic pseudoaneurysm

    Directory of Open Access Journals (Sweden)

    Mesolella Massimo

    2016-01-01

    Full Text Available Blunt trauma to the neck or to the chest are increasingly observed in the emergency clinical practice. They usually follow motor vehicle accidents or may be work or sports related. A wide pattern of clinical presentation can be potentially encountered. We report the uncommon case of a patient who was referred to our observation presenting with hoarseness and disphagia. Twenty days before he had sustained a car accident with trauma to the chest, neck and the mandible. Laryngoscopy showed a left recurrent laryngeal nerve palsy. Further otolaryngo-logical examination showed no other abnormality. At CT and MR imaging a post-traumatic aortic pseudoaneurysm was revealed. The aortic pseudoaneurysm was consequently repaired by implantation of an endovascular stent graft under local anesthesia. The patient was discharged 10 days later. At 30-days follow-up laryngoscopy the left vocal cord palsy was completely resolved.

  1. Impact of Aortic Insufficiency on Ascending Aortic Dilatation and Adverse Aortic Events After Isolated Aortic Valve Replacement in Patients With a Bicuspid Aortic Valve.

    Science.gov (United States)

    Wang, Yongshi; Wu, Boting; Li, Jun; Dong, Lili; Wang, Chunsheng; Shu, Xianhong

    2016-05-01

    Aberrant flow pattern and congenital fragility bestows bicuspid aortic valve (BAV) with a propensity toward ascending aorta dilatation, aneurysm, and dissection. Whether isolated aortic valve replacement (AVR) can prevent further dilatation in BAV ascending aorta and what indicates concurrent aortic intervention in the case of valve operation remain controversial. From June 2006 to January 2009, patients with a BAV who underwent isolated AVR were consecutively included and categorized into aortic insufficiency (BAV-AI, n = 84) and aortic stenosis (n = 112) groups, and another population of patients with a tricuspid aortic valve with aortic insufficiency (n = 149) was also recruited during the same period for comparison of annual aortic dilatation rate and adverse aortic events after isolated AVR. With a median follow-up period of 72 months (interquartile range, 66 to 78 months), ascending aorta dilatation rates were faster in the BAV-AI group than the BAV plus aortic stenosis and tricuspid aortic valve with aortic insufficiency groups (both p regression analysis identified aortic insufficiency (hazard ratio, 3.7; 95% confidence interval, 1.2 to 11.1; p = 0.019) as an independent risk factor for adverse aortic events among patients with BAV in general, whereas preoperative ascending aortic diameter larger than 45 mm (hazard ratio, 13.8; 95% confidence interval, 3.0 to 63.3; p = 0.001) served as a prognostic indicator in the BAV-AI group. An aggressive policy of preventive aortic interventions seemed appropriate in patients with BAV-AI during AVR, and BAV phenotype presenting as either insufficiency or stenosis should be taken into consideration when contemplating optimal surgical strategies for BAV aortopathy. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Aortic Branch Artery Pseudoaneurysms Associated with Intramural Hematoma: When and How to Do Endovascular Embolization

    Energy Technology Data Exchange (ETDEWEB)

    Ferro, Carlo; Rossi, Umberto G., E-mail: urossi76@hotmail.com; Seitun, Sara [IRCCS San Martino University Hospital, IST, National Institute for Cancer Research, Department of Radiology and Interventional Radiology (Italy); Scarano, Flavio; Passerone, Giancarlo [IRCCS San Martino University Hospital, IST, National Institute for Cancer Research, Department of Cardiac Surgery (Italy); Williams, David M. [University of Michigan Medical Center, Department of Radiology, Division of Vascular and Interventional Radiology (United States)

    2013-04-15

    To describe when and how to perform endovascular embolization of aortic branch artery pseudoaneurysms associated with type A and type B intramural hematoma (IMH) involving the descending thoracic and abdominal aorta (DeBakey I and III) that increased significantly in size during follow-up. Sixty-one patients (39 men; mean {+-} standard deviation age 66.1 {+-} 11.2 years) with acute IMH undergoing at least two multidetector computed tomographic examinations during follow-up for 12 months or longer were enrolled. Overall, 48 patients (31 men, age 65.9 {+-} 11.5) had type A and type B IMH involving the descending thoracic and abdominal aorta (DeBakey I and III). Among the 48 patients, 26 (54 %; 17 men, aged 64.3 {+-} 11.4 years) had 71 aortic branch artery pseudoaneurysms. Overall, during a mean follow-up of 22.1 {+-} 9.5 months (range 12-42 months), 31 (44 %) pseudoaneurysms disappeared; 22 (31 %) decreased in size; two (3 %) remained stable; and 16 (22 %) increased in size. Among the 16 pseudoaneurysms with increasing size, five of these (three intercostal arteries, one combined intercostobronchial/intercostal arteries, one renal artery), present in five symptomatic patients, had a significant increase in size (thickness >10 mm; width and length >20 mm). These five patients underwent endovascular embolization with coils and/or Amplatzer Vascular Plug. In all patients, complete thrombosis and exclusion of aortic pseudoaneurysm and relief of back pain were achieved. Aortic branch artery pseudoaneurysms associated with type A and type B IMH involving the descending thoracic and abdominal aorta (DeBakey I and III) may be considered relatively benign lesions. However, a small number may grow in size or extend longitudinally with clinical symptoms during follow-up, and in these cases, endovascular embolization can be an effective and safe procedure.

  3. Direct percutaneous transaortic approach for treatment of aortic pseudoaneurysms.

    Science.gov (United States)

    Pirelli, Luigi; Kliger, Chad; Fontana, Gregory P; Ruiz, Carlos E

    2015-05-01

    Aortic pseudoaneurysms (APAs) can develop months or years after aortic and cardiac surgery. If not treated appropriately, APAs can lead to fatal complications and ultimately death. We describe a case of a 61-year old patient with a diagnosed large pseudoaneurysm 5 years after his aortic valve surgery, who was treated with a novel transcatheter direct transaortic approach. The patient had dilated cardiomyopathy with an APA adjacent to the lower sternal plate. An Amplatzer septal occlusion device followed by coils was delivered transcutaneously through the APA to close its neck and fill the false aneurysm, respectively. Triple fusion multimodality imaging was used to guide the placement of the occlusion devices. The merging of computed tomography (CT) and echocardiography with real-time fluoroscopy was fundamental in procedural planning and guidance. Post-procedural transoesophageal echocardiogram (TOE) and CT angiography showed complete exclusion of the APA. A direct transaortic approach is a valid option for closure of an APA if the surgical risk is prohibitive, and the use of triple fusion technology is an essential tool in the hands of interventionalists and surgeons for preoperative planning and conduction of these procedures. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  4. MMP-2 Isoforms in Aortic Tissue and Serum of Patients with Ascending Aortic Aneurysms and Aortic Root Aneurysms

    Science.gov (United States)

    Tscheuschler, Anke; Meffert, Philipp; Beyersdorf, Friedhelm; Heilmann, Claudia; Kocher, Nadja; Uffelmann, Xenia; Discher, Philipp; Siepe, Matthias; Kari, Fabian A.

    2016-01-01

    Objective The need for biological markers of aortic wall stress and risk of rupture or dissection of ascending aortic aneurysms is obvious. To date, wall stress cannot be related to a certain biological marker. We analyzed aortic tissue and serum for the presence of different MMP-2 isoforms to find a connection between serum and tissue MMP-2 and to evaluate the potential of different MMP-2 isoforms as markers of high wall stress. Methods Serum and aortic tissue from n = 24 patients and serum from n = 19 healthy controls was analyzed by ELISA and gelatin zymography. 24 patients had ascending aortic aneurysms, 10 of them also had aortic root aneurysms. Three patients had normally functioning valves, 12 had regurgitation alone, eight had regurgitation and stenosis and one had only stenosis. Patients had bicuspid and tricuspid aortic valves (9/15). Serum samples were taken preoperatively, and the aortic wall specimen collected during surgical aortic repair. Results Pro-MMP-2 was identified in all serum and tissue samples. Pro-MMP-2 was detected in all tissue and serum samples from patients with ascending aortic/aortic root aneurysms, irrespective of valve morphology or other clinical parameters and in serum from healthy controls. We also identified active MMP-2 in all tissue samples from patients with ascending aortic/aortic root aneurysms. None of the analyzed serum samples revealed signals relatable to active MMP-2. No correlation between aortic tissue total MMP-2 or tissue pro-MMP-2 or tissue active MMP-2 and serum MMP-2 was found and tissue MMP-2/pro-MMP-2/active MMP-2 did not correlate with aortic diameter. This evidence shows that pro-MMP-2 is the predominant MMP-2 species in serum of patients and healthy individuals and in aneurysmatic aortic tissue, irrespective of aortic valve configuration. Active MMP-2 species are either not released into systemic circulation or not detectable in serum. There is no reliable connection between aortic tissue—and serum MMP-2

  5. Aortic annulus and ascending aorta: Comparison of preoperative and periooperative measurement in patients with aortic stenosis

    International Nuclear Information System (INIS)

    Smid, Michal; Ferda, Jiri; Baxa, Jan; Cech, Jakub; Hajek, Tomas; Kreuzberg, Boris; Rokyta, Richard

    2010-01-01

    Background: Precise determination of the aortic annulus size constitutes an integral part of the preoperative evaluation prior to aortic valve replacement. It enables the estimation of the size of prosthesis to be implanted. Knowledge of the size of the ascending aorta is required in the preoperative analysis and monitoring of its dilation enables the precise timing of the operation. Our goal was to compare the precision of measurement of the aortic annulus and ascending aorta using magnetic resonance (MR), multidetector-row computed tomography (MDCT), transthoracic echocardiography (TTE), and transoesophageal echocardiography (TEE) in patients with degenerative aortic stenosis. Methods and results: A total of 15 patients scheduled to have aortic valve replacement were enrolled into this prospective study. TTE was performed in all patients and was supplemented with TEE, CT and MR in the majority of patients. The values obtained were compared with perioperative measurements. For the measurement of aortic annulus, MR was found to be the most precise technique, followed by MDCT, TTE, and TEE. For the measurement of ascending aorta, MR again was found to be the most precise technique, followed by MDCT, TEE, and TTE. Conclusion: In our study, magnetic resonance was found to be the most precise technique for the measurement of aortic annulus and ascending aorta in patients with severe degenerative aortic stenosis.

  6. Ascending Aortic Dimensions in Former National Football League Athletes.

    Science.gov (United States)

    Gentry, James L; Carruthers, David; Joshi, Parag H; Maroules, Christopher D; Ayers, Colby R; de Lemos, James A; Aagaard, Philip; Hachamovitch, Rory; Desai, Milind Y; Roselli, Eric E; Dunn, Reginald E; Alexander, Kezia; Lincoln, Andrew E; Tucker, Andrew M; Phelan, Dermot M

    2017-11-01

    Ascending aortic dimensions are slightly larger in young competitive athletes compared with sedentary controls, but rarely >40 mm. Whether this finding translates to aortic enlargement in older, former athletes is unknown. This cross-sectional study involved a sample of 206 former National Football League (NFL) athletes compared with 759 male subjects from the DHS-2 (Dallas Heart Study-2; mean age of 57.1 and 53.6 years, respectively, P 40 mm (29.6% versus 8.6%; P history of hypertension, current smoking, diabetes mellitus, and lipid profile, the former NFL athletes still had significantly larger ascending aortas ( P 40 mm after adjusting for the same parameters. Ascending aortic dimensions were significantly larger in a sample of former NFL athletes after adjusting for their size, age, race, and cardiac risk factors. Whether this translates to an increased risk is unknown and requires further evaluation. © 2017 American Heart Association, Inc.

  7. Aortic pseudoaneurysm detected on external jugular venous distention following a Bentall procedure 10 years previously.

    Science.gov (United States)

    Fukunaga, Naoto; Shomura, Yu; Nasu, Michihiro; Okada, Yukikatsu

    2010-11-01

    An asymptomatic 49-year-old woman was admitted for the purpose of surgery for aortic pseudoaneurysm. She had Marfan syndrome and had undergone an emergent Bentall procedure 10 years previously. About six months previously, she could palpate distended bilateral external jugular veins, which became distended only in a supine position and without any other symptoms. Enhanced computed tomography revealed an aortic pseudoaneurysm originating from a previous distal anastomosis site. During induction of general anesthesia in a supine position, bilateral external jugular venous distention was remarkable. Immediately after a successful operation, distention completely resolved. The present case emphasizes the importance of physical examination leading to a diagnosis of asymptomatic life-threatening diseases in patients with a history of previous aortic surgery.

  8. Reverse extra-anatomic aortic arch debranching procedure allowing thoracic endovascular aortic repair of a chronic ascending aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Ludovic Canaud, MD, PhD

    2018-06-01

    Full Text Available A 79-year-old woman was admitted with a large chronic dissecting ascending aortic aneurysm starting 5 mm distal to the ostia of the left coronary artery and ending immediately proximal to the innominate artery. A reverse extra-anatomic aortic arch debranching procedure was performed. During the same operative time, through a transapical approach, a thoracic stent graft was deployed with the proximal landing zone just distal to the coronary ostia and the distal landing zone excluding the origin of the left common carotid artery. The postoperative course was uneventful. Computed tomography at 12 months documented patent extra-anatomic aortic arch debranching and no evidence of endoleak. Keywords: Ascending aorta, Thoracic aorta, Aortic dissection, Stent graft

  9. Diminutive Porcelain Ascending Aorta With Supravalvular Aortic Stenosis.

    Science.gov (United States)

    Houmsse, Mustafa; McDavid, Asia; Kilic, Ahmet

    2018-05-01

    This report describes the case of a 49-year-old man with a medical history significant for congenital aortic stenosis. The patient presented with progressive shortness of breath and decreased stamina and was found to have a concentric, diminutive porcelain ascending aorta with diffuse supravalvular aortic stenosis. We describe treatment with an aortic root augmentation and Bentall procedure using hypothermic circulatory arrest. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Monozygotic twins with Marfan's syndrome and ascending aortic aneurysm.

    Science.gov (United States)

    Redruello, Héctor Jorge; Cianciulli, Tomas Francisco; Rostello, Eduardo Fernandez; Recalde, Barbara; Lax, Jorge Alberto; Picone, Victorio Próspero; Belforte, Sandro Mario; Prezioso, Horacio Alberto

    2007-08-01

    Marfan's syndrome is a hereditary connective tissue disease, in which cardiovascular abnormalities (especially aortic root dilatation) are the most important cause of morbidity and mortality. In this report, we describe two 24-year-old twins, with a history of surgery for lens subluxation and severe cardiovascular manifestations secondary to Marfan's syndrome. One of the twins suffered a type A aortic dissection, which required replacement of the ascending aorta, and the other twin had an aneurysmal dilatation of the ascending aorta (46mm) and was prescribed medical treatment with atenolol and periodic controls to detect the presence of a critical diameter (50mm) that would indicate the need for prophylactic surgery.

  11. Fate of remnant sinuses of Valsalva in patients with bicuspid and trileaflet valves undergoing aortic valve, ascending aorta, and aortic arch replacement.

    Science.gov (United States)

    Milewski, Rita Karianna; Habertheuer, Andreas; Bavaria, Joseph E; Siki, Mary; Szeto, Wilson Y; Krause, Eric; Korutla, Varun; Desai, Nimesh D; Vallabhajosyula, Prashanth

    2017-08-01

    In patients presenting with aortic valvulopathy with concomitant ascending aortic aneurysm, surgical management of the sinus of Valsalva segment remains undefined, especially for moderately dilated aortic roots. In patients with this pathology undergoing aortic valve replacement with supracoronary ascending aorta replacement, we assessed the fate of the remnant preserved sinus of Valsalva segment stratified by aortic valve morphology and pathology. From 2002 to 2015, 428 patients underwent elective aortic valve replacement with supracoronary ascending aorta replacement. Patients were stratified on the basis of valvular morphology (bicuspid aortic valve [n = 254] and tricuspid aortic valve [n = 174]), valvular pathology (bicuspid aortic valve with aortic stenosis [n = 178], bicuspid aortic valve with aortic insufficiency [n = 76], tricuspid aortic valve with aortic stenosis [n = 61], tricuspid aortic valve with aortic insufficiency [n = 113]), and preoperative sinus of Valsalva dimensions (45 mm). Kaplan-Meier analysis revealed no significant difference in freedom from reoperation in tricuspid aortic valve versus bicuspid aortic valve (P = .576). Multivariable Cox regression model performed with sinus of Valsalva dimensions at baseline and follow-up as time-varying covariates did not adversely affect survival. A repeated-measure, mixed-effects model constructed to assess longitudinal sinus of Valsalva trends revealed that the retained sinus of Valsalva dimensions remain stable over long-term follow-up (discharge to ≥10 years), irrespective of valvular morphology/pathology (bicuspid aortic valve with aortic insufficiency, tricuspid aortic valve with aortic insufficiency, tricuspid aortic valve with aortic stenosis) and preoperative sinus of Valsalva groups (45 mm). In patients with nonaneurysmal sinuses of Valsalva undergoing aortic valve replacement with supracoronary ascending aorta replacement, the sinus segment can be preserved irrespective of

  12. Retrograde ascending aortic dissection during or after thoracic aortic stent graft placement: insight from the European registry on endovascular aortic repair complications

    DEFF Research Database (Denmark)

    Eggebrecht, Holger; Thompson, Matt; Rousseau, Hervé

    2009-01-01

    BACKGROUND: Single-center reports have identified retrograde ascending aortic dissection (rAAD) as a potentially lethal complication of thoracic endovascular aortic repair (TEVAR). METHODS AND RESULTS: Between 1995 and 2008, 28 centers participating in the European Registry on Endovascular Aortic...

  13. Pulmonary artery stenosis caused by a large aortic arch pseudoaneurysm detected 10 years after a minor trauma

    Directory of Open Access Journals (Sweden)

    Jalal Zamani

    2016-03-01

    Full Text Available Pseudoaneurysm of aorta is a rare condition usually seen after aortic surgeries or serious accidents. Here we report a 60 years old man without any previous medical condition who presented with non-specific symptoms and underwent different investigations for more than 1 year, until the presence of a continuous murmur raised suspicion toward his cardiovascular system. In echocardiographic and computed tomography (CT angiographic studies a large pseudoaneurysm of aortic arch with compression effect on pulmonary artery was detected. At this stage he remembered having suffered a minor trauma 10 years ago. He finally underwent operation and his aortic wall was repaired successfully with a patch. This case highlights the importance of thorough history taking and physical examination in patients irrespective of symptoms and high index of suspicion to detect this life-threatening condition.

  14. Aortic allografts in treatment of aortic valve and ascending aorta prosthetic endocarditis

    Directory of Open Access Journals (Sweden)

    S.V. Spiridonov

    2017-03-01

    Full Text Available The aim – to assess short- and long-term results of aortic root replacement using aortic allografts in patients with prosthetic endocarditis. Materials and methods. Since February 2009 until June 2016 aortic valve and ascending aorta replacement using aortic allografts was performed in 26 patients with prosthetic endocarditis. In 50 % of cases at initial operation aortic valve replacement was performed, in another 50 % of cases – aortic valve and ascending aorta replacement. Echocardiography was performed 10 days, 3, 6 and 12 months, 2, 3 and 5 years after surgery. Analysis of long-term results included all cases of deaths, prosthesis-related complications and recurrence of endocarditis. Results. 30-day mortality was 23.1 %. Extracorporeal membranous oxygenation (ECMO was used only in 5 patients (19.2 %. Four patients were weaned from ECMO. We did not observe any allograft-related complications. During follow-up period there were no cases of reoperation due to structural allograft failure. Relapse of infection occurred in 1 patient (3.8 % four years after the operation and led to lethal outcome. Conclusion. Reoperations using allografts are an effective surgical treatment of prosthetic endocarditis. In majority of cases prosthetic endocarditis was caused by gram-positive cocci (Staphylococcus. In 84.6 % of cases it was associated with destruction of paravalvular structures and abscesses formation. Heart failure was a causative factor of different complications in these patients, which required ECMO in 19.2 % of patients. In 80 % of cases patients were weaned from ECMO. Allografts using for the treatment of prosthetic endocarditis is associated with high resistance to infection and with a significant rate of freedom from recurrence of endocarditis within 3 years after surgery.

  15. Ascending Aortic Wall Cohesion: Comparison of Bicuspid and Tricuspid Valves

    Directory of Open Access Journals (Sweden)

    Jaroslav Benedik

    2012-01-01

    Full Text Available Objectives. Bicuspid aortic valve (AV represents the most common form of congenital AV malformation, which is frequently associated with pathologies of the ascending aorta. We compared the mechanical properties of the aortic wall between patients with bicuspid and tricuspid AV using a new custom-made device mimicking transversal aortic wall shear stress. Methods. Between 03/2010 and 07/2011, 190 consecutive patients undergoing open aortic valve replacement at our institution were prospectively enrolled, presenting either with a bicuspid (group 1, n=44 or a tricuspid (group 2, n=146 AV. Aortic wall specimen were examined with the “dissectometer” resulting in nine specific aortic-wall parameters derived from tensile strength curves (TSC. Results. Patients with a bicuspid AV showed significantly more calcified valves (43.2% versus 15.8%, P<0.001, and a significantly thinner aortic wall (2.04±0.42 mm versus 2.24±0.41 mm, P=0.008. Transesophageal echocardiography diameters (annulus, aortic sinuses, and sinotubular junction were significantly larger in the bicuspid group (P=0.003, P=0.02, P=0.01. We found no difference in the aortic wall cohesion between both groups as revealed by shear stress testing (P=0.72, P=0.40, P=0.41. Conclusion. We observed no differences of TSC in patients presenting with tricuspid or bicuspid AVs. These results may allow us to assume that the morphology of the AV and the pathology of the ascending aorta are independent.

  16. Zone zero thoracic endovascular aortic repair: A proposed modification to the classification of landing zones.

    Science.gov (United States)

    Roselli, Eric E; Idrees, Jay J; Johnston, Douglas R; Eagleton, Matthew J; Desai, Milind Y; Svensson, Lars G

    2018-04-01

    Endovascular stent-grafting provides an alternative treatment option for high-risk patients with ascending aortic disease. The feasibility of this approach has been demonstrated before. We assess the updated experience with ascending thoracic endovascular aortic repair and propose a modification of the landing zone classification based on the outcomes. From 2006 to 2016, 39 patients deemed very high risk for open replacement underwent endovascular repair of ascending aorta for acute type A dissection (12, 31%), intramural hematoma (2, 5%), pseudoaneurysm (22, 56%), and chronic dissection suture line entry tear (3, 8%). Ascending thoracic endovascular aortic repair was performed in 36 patients. In 3 patients with pseudoaneurysm, occluder devices were used. Computed tomography imaging analysis was performed, and the extent of aortic pathology was designated by segmental proximity to the left ventricle. Segmental anatomy of the proximal aorta was designed as zone 0A from the annulus to the distal margin of highest coronary, 0B extends from above the coronary to the distal margin of right pulmonary artery, and 0C extends from the right pulmonary artery border to the innominate artery. Multivariable time to event Cox regression analysis was performed to predict mortality, and long-term survival was estimated using the Kaplan-Meier method. Operative mortality was 13%; all 5 deaths occurred after emergency ascending thoracic endovascular aortic repair for type A dissection. Other complications included stroke in 4 patients (10%), myocardial infarction in 2 patients (5%), tracheostomy in 2 patients (5%), and dialysis in 2 patients (5%). In patients with acute type A dissection, the ascending pathology extended into zone 0A in 10 (71%) and 0B in 4 (29%). Among those with pseudoaneurysm, the location of the defect was in 0B in 11 (50%), 0C in 10 (45%), and 0A in 1. Among the patients with chronic dissection, the defect was located in 0C in all 3 (100%). After multivariable

  17. Characteristics of aortic valve dysfunction and ascending aorta dimensions according to bicuspid aortic valve morphology

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Hong Ju [Konkuk University Medical Center, Konkuk University School of Medicine, Department of Cardiovascular Surgery, Seoul (Korea, Republic of); Yonsei University College of Medicine, Department of Cardiovascular Surgery, Seoul (Korea, Republic of); Shin, Je Kyoun; Chee, Hyun Kun; Kim, Jun Suk [Konkuk University Medical Center, Konkuk University School of Medicine, Department of Cardiovascular Surgery, Seoul (Korea, Republic of); Ko, Sung Min [Konkuk University Medical Center, Konkuk University School of Medicine, Department of Radiology, Seoul (Korea, Republic of)

    2015-07-15

    To characterize aortic valve dysfunction and ascending aorta dimensions according to bicuspid aortic valve (BAV) morphology using computed tomography (CT) and surgical findings. We retrospectively enrolled 209 patients with BAVs who underwent transthoracic echocardiography (TTE) and CT. BAVs were classified as anterior-posterior (BAV-AP) or lateral (BAV-LA) orientation of the cusps and divided according to the presence (raphe+) or absence (raphe-) of a raphe. Ascending aortic dimensions were measured by CT at four levels. BAV-AP was present in 129 patients (61.7 %) and raphe+ in 120 (57.4 %). Sixty-nine patients (33.0 %) had aortic regurgitation (AR), 70 (33.5 %) had aortic stenosis (AS), and 58 (27.8 %) had combined AS and AR. AR was more common in patients with BAV-AP and raphe+; AS was more common with BAV-LA and raphe-.Annulus/body surface area and tubular portion/body surface area diameters in patients with BAV-AP (17.1 ± 2.3 mm/m{sup 2} and 24.2 ± 5.3 mm/m{sup 2}, respectively) and raphe+ (17.3 ± 2.2 mm/m{sup 2} and 24.2 ± 5.5 mm/m{sup 2}, respectively) were significantly different from those with BAV-LA (15.8 ± 1.9 mm/m{sup 2} and 26.4 ± 5.5 mm/m{sup 2}, respectively) and raphe- (15.7 ± 1.9 mm/m{sup 2} and 26.2 ± 5.4 mm/m{sup 2}, respectively). The morphological characteristics of BAV might be associated with the type of valvular dysfunction, and degree and location of an ascending aorta dilatation. (orig.)

  18. Hybrid aortic repair with antegrade supra-aortic and renovisceral debranching from ascending aorta.

    Science.gov (United States)

    Del Castro-Madrazo, José Antonio; Rivas-Domínguez, Margarita; Fernández-Prendes, Carlota; Zanabili Al-Sibbai, Amer; Llaneza-Coto, José Manuel; Alonso-Pérez, Manuel

    2017-05-01

    Aortic dissection is a life threatening condition. Hybrid repair has been described for the treatment of complex aortic pathology such as thoracoabdominal aortic aneurysms (TAAA) and type A and B dissections, although open and total endovascular repair are also possible. Open surgery is still associated with substantial perioperative morbi-mortality rates, thus less invasive techniques such as endovascular repair and hybrid procedures can achieve good results in centers with experience. We present the case of a patient with a chronic type B dissection and TAAA degeneration that was treated in a single stage hybrid procedure with antegrade supra-aortic and renovisceral debranching from the ascending aorta and TEVAR. At three-year follow up, the patient is free of intervention-related complications.

  19. Results of aortic root reimplantation in patients with ascending aortic aneurysm and concomitant aortic insufficiency

    Directory of Open Access Journals (Sweden)

    А. М. Чернявский

    2016-01-01

    Full Text Available Objective. The research was designed to evaluate the results of valve-sparing operations: aortic root reimplantation versus aortic valve reimplantation when repairing an ascending aortic aneurysm with concomitant aortic insufficiency.Methods. Within a blind prospective randomized study conducted over a period from 2011 to 2015, 64 patients underwent aortic valve-sparing surgery. The inclusion criteria were the presence of an aortic aneurysm of the ascending aorta exceeding 4.5 cm and concomitant aortic insufficiency. All patients were divided into two groups: FS-group, aortic root reimplantation (modified Florida Sleeve technique (n = 32 and D-group, aortic valve reimplantation (David procedure (n = 32. The average age of patients was 57±13 (23–73 years in the FS-group and 55±11 (15–72 years in the D-group (p = 0.54. Both groups had 78% of males (p>0.99. A Marfan syndrome was identified in 6% and 9% in the FS-group and D-group respectively (p>0.99. Mean diameter of the sinuses of Valsalva was 51±7 mm and 56±10 mm (p = 0.09, aortic insufficiency 2.6±0.7 and 2.8±0.8 (p = 0.15 in the FS-group and D-group respectively. In the FS-group and D-group LVEDD amounted to 5.5±0.7 mm and 5.9±1.0 mm (p = 0.09 respectively. All patients took echocardiography in the preoperative, postoperative and follow-up periods.Results. In the long-term period, the degree of aortic regurgitation was 1.2±0.1 in the FS-group and 1.3±0.6 in the D-group (p = 0.72. LVEDD was 123±23 mm in the FS-group and 139.6±80 mm in the D-group at follow-up (p = 0.77. There were no statistically significant differences in the analysis of complications. Overall 30-day in-hospital mortality was 7.8%. There were 2 (6.3% deaths in the FS-group and 3 (9.4% in the D-group (p = 0.5.Late mortality was 6.3% in the FS-group and 3.1% in the D-group (p>0.99. Cumulative survival at 4 years was 84.3% and 84.8% in the FS-group and the D-group respectively (p = 0.94. Cumulative freedom from

  20. Overexpression of interleukin-1β and interferon-γ in type I thoracic aortic dissections and ascending thoracic aortic aneurysms: possible correlation with matrix metalloproteinase-9 expression and apoptosis of aortic media cells.

    Science.gov (United States)

    Zhang, Lei; Liao, Ming-fang; Tian, Lei; Zou, Si-li; Lu, Qing-sheng; Bao, Jun-min; Pei, Yi-fei; Jing, Zai-ping

    2011-07-01

    To examine the expression of interleukin-1β and interferon-γ and their possible roles in aortic dissections and aneurysms. Aortic specimens were obtained from patients with type I thoracic aortic dissection, ascending thoracic aortic aneurysms, and control organ donors. The expression of interleukin-1β, interferon-γ, matrix metalloproteinase-9, and signal transduction factors phospho-p38 and phosphorylated c-jun N-terminal kinase (phospho-JNK) were detected by real time reverse transcription-polymerase chain reaction (real time RT-PCR), Western blot, and immunohistochemistry, respectively. Terminal deoxynucleotidyl transferase dUTP nick-end labeling (TUNEL) staining was performed to detect apoptosis of media cells. The correlation of these factors and apoptosis was also studied. Apoptosis in the media of thoracic aortic dissection and in ascending thoracic aortic aneurysms was dramatically higher than in the control group. The expression of interleukin-1β gradually increased from the control group, thoracic aortic dissection to ascending thoracic aortic aneurysms (p matrix metalloproteinase-9 was significantly increased in the media of thoracic aortic dissection and ascending thoracic aortic aneurysms compared with the control group (p correlations between interleukin-1β versus matrix metalloproteinase-9, interleukin-1β versus phospho-p38 in thoracic aortic dissection (p matrix metalloproteinase-9, interferon-γ versus phospho-JNK, interferon-γ versus apoptosis, and interleukin-1β versus apoptosis in ascending thoracic aortic aneurysms (p = 0.02, 0.02, p matrix metalloproteinase-9 and the apoptosis of media cells in humans. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  1. Juxtarenal Aortic Pseudoaneurysm – Right Renal Vein Fistula with Circumaortic Renal Collar-Delayed Manifestation of a Gunshot Injury – an Uncommon Entity Diagnosed with CT Angiography

    International Nuclear Information System (INIS)

    Garg, Lalit; Jain, Neeraj; Agrawal, Sachin; Chauhan, Udit; Goel, Vandana; Puri, Sunil Kumar

    2016-01-01

    Delayed presentation of post-traumatic aortic pseudoaneurysm and its fistulous communication with the right renal vein is a very rare entity. Most of the cases described in literature are due to abdominal aortic aneurysm (AAA) rupture into the left renal vein. To the best of our knowledge, communication with the right renal vein has not been described in published literature. Our patient also had a circumaortic renal collar, which is a rare renal vein anomaly. Aortic pseudoaneurysm, its fistulous communication with the right renal vein and circumaortic renal collar in a single patient is of extremely rare occurrence. A 29-year-old male presented to the cardiology department with complaints of breathlessness, abdominal pain and hematuria for the last 6 months. On clinical examination there was evidence of audible bruit over the abdomen. He had a past history of a gunshot injury around two years back. CT angiography revealed a large partially calcified pseudoaneurysm arising from the right lateral wall of the abdominal aorta with the neck of the pseudoaneurysm at juxtarenal location with a fistula between the anterior wall of the pseudoaneurysm and the posterior wall of the right renal vein. There was an associated incidental finding of circumaortic left renal vein with gross aneurysmal dilatation of both pre- and retro-aortic part of the renal vein. Delayed presentation of aortic pseudoaneurysm with its fistulous communication with the right renal vein is a rare entity. CT angiography is a non-invasive modality for diagnosis of the exact site of communication, length of aneurysm, proximal and distal extent of the affected segment and its relationship with surrounding structures

  2. Subacute Staphylococcus epidermidis Bacterial Endocarditis Complicated by Mitral-Aortic Intervalvular Fibrosa Pseudoaneurysm

    Directory of Open Access Journals (Sweden)

    Diane Elegino-Steffens

    2012-01-01

    Full Text Available The patient is a 75-year-old man with a history significant for hypertension and congestive heart failure who underwent a bioprosthetic aortic valve replacement secondary to acute onset of aortic insufficiency. Cultures of the native valve were positive for Staphylococcus epidermidis sensitive to nafcillin and intravenous cefazolin was initiated. On postoperative day 24, he developed acute decompensated heart failure. A transesophageal echocardiogram demonstrated a structurally abnormal mitral valve with severe regurgitation, anterior and posterior leaflet vegetations, and scallop prolapse. There was also evidence of a mitral-aortic intervalvular fibrosa pseudoaneurysm (P-MAIF with systolic expansion and flow within the aneurysm. Antibiotic treatment was changed from cefazolin to vancomycin for presumed development of methicillin-resistant Staphylococcus. He subsequently underwent a bioprosthetic mitral valve replacement and has restoration of health without sequella. This case highlights the development of a P-MAIF as a rare complication of both aortic or mitral valve replacement and infective endocarditis.

  3. Synchronized epiaortic two-dimensional and color Doppler echocardiographic guidance enables routine ascending aortic cannulation in type A acute aortic dissection.

    Science.gov (United States)

    Inoue, Yoshito; Takahashi, Ryuichi; Ueda, Toshihiko; Yozu, Ryohei

    2011-02-01

    Preference for arterial inflow during surgery for type A acute aortic dissection remains controversial. Antegrade central perfusion prevents malperfusion and retrograde embolism, and the ascending aorta provides arterial access for rapid establishment of systemic perfusion, especially if there is hemodynamic instability. It has not been used routinely, however, because of the disruption caused to the aorta. We evaluated the safety and efficacy of routine cannulation of the dissected aorta for the repair of type A dissection. Surgical results were analyzed for 83 consecutive patients with type A acute aortic dissection between 2002 and 2009. They were treated surgically by prosthetic graft replacement under hypothermic circulatory arrest. The ascending aorta was routinely cannulated using the Seldinger technique with epiaortic echocardiographic guidance; antegrade systemic perfusion was evaluated by color Doppler ultrasound. Systemic antegrade perfusion via the dissected ascending aorta was performed safely in all cases. There was no malperfusion or thromboembolism as a result of ascending aortic cannulation. Epiaortic 2-dimensional and color Doppler imaging provided real-time monitoring adequate for the placement and for proper systemic perfusion. There were 5 in-hospital deaths (5/83=6.0%) and 8 strokes (preoperative 6/83=7.2%, postoperative 2/83=2.4%). A total of 78 patients (78/83=94%) were discharged and have been followed up without major adverse cardiac events for a mean duration of 31.8 months. Ascending aortic cannulation is a simple and safe technique that provides a rapid and reliable route of antegrade central systemic perfusion in type A aortic dissection. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  4. Pseudoaneurysm of mitral-aortic intervalvular fibrosa in a child: Demonstration by MDCT and MRI

    International Nuclear Information System (INIS)

    Choh, Naseer A; Shaheen, Feroze; Rather, Hilal; Aslam, Khursheed

    2013-01-01

    Subaortic left ventricular outflow tract pseudoaneurysms are rare lesions that are associated with aortic valve diseases, infective endocarditis, trauma or surgery. We present dynamic multidetector computerized tomography and cine magnetic resonance imaging features of a case of subaortic aneurysm arising from interaortic-mitral valvular region in a child with past history of infective endocarditis

  5. Compression of the right coronary artery by an aortic pseudoaneurysm after infective endocarditis: an unusual case of myocardial ischemia.

    Science.gov (United States)

    Lacalzada-Almeida, Juan; De la Rosa-Hernández, Alejandro; Izquierdo-Gómez, María Manuela; García-Niebla, Javier; Hernández-Betancor, Iván; Bonilla-Arjona, Juan Alfonso; Barragán-Acea, Antonio; Laynez-Cerdeña, Ignacio

    2018-01-01

    A 61-year-old male with a prosthetic St Jude aortic valve size 24 presented with heart failure symptoms and minimal-effort angina. Eleven months earlier, the patient had undergone cardiac surgery because of an aortic root dilatation and bicuspid aortic valve with severe regurgitation secondary to infectious endocarditis by Coxiela burnetii and coronary artery disease in the left circumflex coronary artery. Then, a prosthesis valve and a saphenous bypass graft to the left circumflex coronary artery were placed. The patient was admitted to the Cardiology Department of Hospital Universitario de Canarias, Tenerife, Spain and a transthoracic echocardiography was performed that showed severe paraprosthetic aortic regurgitation and an aortic pseudoaneurysm. The 64-slice multidetector computed tomography confirmed the pseudoaneurysm, originating from the right sinus of Valsalva, with a compression of the native right coronary artery and a normal saphenous bypass graft. On the basis of these findings, we performed surgical treatment with a favorable postoperative evolution. In our case, results from complementary cardiac imaging techniques were crucial for patient management. The multidetector computed tomography allowed for a confident diagnosis of an unusual mechanism of coronary ischemia.

  6. Compression of the right coronary artery by an aortic pseudoaneurysm after infective endocarditis: an unusual case of myocardial ischemia

    Directory of Open Access Journals (Sweden)

    Lacalzada-Almeida J

    2017-12-01

    Full Text Available Juan Lacalzada-Almeida,1 Alejandro De la Rosa-Hernández,1 María Manuela Izquierdo-Gómez,1 Javier García-Niebla,2 Iván Hernández-Betancor,1 Juan Alfonso Bonilla-Arjona,3 Antonio Barragán-Acea,1 Ignacio Laynez-Cerdeña1 1Cardiology Department, Hospital Universitario de Canarias, Tenerife, 2Health services from the Health Area of El Hierro, Valle del Golfo Health Center, El Hierro, 3Radiology Department, Hospital Universitario de Canarias, Tenerife, Spain Abstract: A 61-year-old male with a prosthetic St Jude aortic valve size 24 presented with heart failure symptoms and minimal-effort angina. Eleven months earlier, the patient had undergone cardiac surgery because of an aortic root dilatation and bicuspid aortic valve with severe regurgitation secondary to infectious endocarditis by Coxiela burnetii and coronary artery disease in the left circumflex coronary artery. Then, a prosthesis valve and a saphenous bypass graft to the left circumflex coronary artery were placed. The patient was admitted to the Cardiology Department of Hospital Universitario de Canarias, Tenerife, Spain and a transthoracic echocardiography was performed that showed severe paraprosthetic aortic regurgitation and an aortic pseudoaneurysm. The 64-slice multidetector computed tomography confirmed the pseudoaneurysm, originating from the right sinus of Valsalva, with a compression of the native right coronary artery and a normal saphenous bypass graft. On the basis of these findings, we performed surgical treatment with a favorable postoperative evolution. In our case, results from complementary cardiac imaging techniques were crucial for patient management. The multidetector computed tomography allowed for a confident diagnosis of an unusual mechanism of coronary ischemia. Keywords: pseudoaneurysm, infective endocarditis, myocardial ischemia, aortic valve prosthesis

  7. Elevation of Matrix Metalloproteinases in Different Areas of Ascending Aortic Aneurysms in Patients with Bicuspid and Tricuspid Aortic Valves

    Directory of Open Access Journals (Sweden)

    Salah A. Mohamed

    2012-01-01

    Full Text Available Our aim is to investigate the elevation of matrix proteins in tissues obtained from distal, above the sinotubular junction (proximal, concave, and convex sites of aneurysms in the ascending aorta using a simultaneous multiplex protein detection system. Tissues were collected from 41 patients with ascending aortic aneurysms. A total of 31 patients had a bicuspid aortic valve (BAV, whereas 10 had a tricuspid aortic valve (TAV. Concave and convex aortic site samples were collected from all patients, whereas proximal and distal convexity samples were obtained from 19 patients with BAV and 7 patients with TAV. Simultaneous detection of matrix metalloproteinases (MMPs and their inhibitors (TIMPs was performed at each of the four aortic sites. MMP-2 levels were higher in the concave aortic sites than in the convex aortic sites. In contrast, MMP-8 levels were higher in the convex sites than in the concave sites, as were MMP-9 levels. In both BAV and TAV patients, TIMP-3 levels were higher in the concave sites than in the convex sites. However, TIMP-2 and TIMP-4 levels were significantly elevated in the sinotubular proximal aorta of BAV patients. Simultaneous detection of MMPs and TIMPs revealed different levels at different aortic sites in the same patient.

  8. Case report and review of the literature total endovascular repair of acute ascending aortic rupture: a case report and review of the literature.

    Science.gov (United States)

    McCallum, John C; Limmer, Karl K; Perricone, Anthony; Bandyk, Dennis; Kansal, Nikhil

    2013-07-01

    Thoracic aortic endografting has been successfully implemented to treat aneurysmal disease of the distal aortic arch and descending thoracic aorta. Although there are reports of ascending aortic endovascular interventions, the total endovascular repair of a ruptured ascending aorta secondary to a Type A dissection has not been described. We report the case of a 77-year-old patient who presented with a ruptured ascending aortic aneurysm secondary to degeneration of a Stanford type A aortic dissection. His surgical history was significant for orthotropic heart transplant 19 years prior. The dissection, aneurysm, and rupture occurred in the native aorta distal to the ascending aortic suture line. At presentation, he was hemodynamically unstable with a right hemothorax. We placed 3 Medtronic Talent Thoracic Stent Graft devices (Medtronic Inc, Minneapolis, MN) across the suture line in the ascending aorta, excluding the rupture. The patient survived and has been followed to 25 months.

  9. Percutaneous coil embolization of massive pelvic pseudoaneurysm in an infant.

    Science.gov (United States)

    Lillis, Anna P; Shaikh, Raja; Alomari, Ahmad I; Chaudry, Gulraiz

    2015-06-01

    Iatrogenic pseudoaneurysm formation is an uncommon but potentially serious complication of cardiac catheterization. This case report describes diagnosis and treatment of a large left external iliac artery pseudoaneurysm in a 3-month-old boy following cardiac catheterization and aortic balloon dilatation for aortic coarctation. A 4-cm pulsatile mass in the left hemipelvis was discovered on MRI performed 6 weeks later for possible tethered spinal cord. Sonography and angiography showed a large pseudoaneurysm of the left external iliac artery just distal to the iliac bifurcation with no flow in the external iliac artery distal to the pseudoaneurysm. Percutaneous US-guided thrombin injection was performed twice, with partial recanalization after each treatment. The residual portion of the pseudoaneurysm was then successfully embolized with percutaneous coils deployed under US and fluoroscopic guidance.

  10. Aortic root replacement after previous surgical intervention on the aortic valve, aortic root, or ascending aorta.

    Science.gov (United States)

    Kirsch, E W Matthias; Radu, N Costin; Mekontso-Dessap, Armand; Hillion, Marie-Line; Loisance, Daniel

    2006-03-01

    Aortic root replacement after a previous operation on the aortic valve, aortic root, or ascending aorta remains a major challenge. Records of 56 consecutive patients (44 men; mean age, 56.4 +/- 13.6 years) undergoing reoperative aortic root replacement between June 1994 and June 2005 were reviewed retrospectively. Reoperation was performed 9.4 +/- 6.7 years after the last cardiac operation. Indications for reoperation were true aneurysm (n = 14 [25%]), false aneurysm (n = 10 [18%]), dissection or redissection (n = 9 [16%]), structural or nonstructural valve dysfunction (n = 10 [18%]), prosthetic valve-graft infection (n = 12 [21%]), and miscellaneous (n = 1 [2%]). Procedures performed were aortic root replacement (n = 47 [84%]), aortic root replacement plus mitral valve procedure (n = 5 [9%]), and aortic root replacement plus arch replacement (n = 4 [7%]). In 14 (25%) patients coronary artery bypass grafting had to be performed unexpectedly during the same procedure or immediately after the procedure to re-establish coronary perfusion. Hospital mortality reached 17.9% (n = 10). Multivariate logistic regression analysis revealed the need for unplanned perioperative coronary artery bypass grafting as the sole independent risk factor for hospital death (P = .005). Actuarial survival was 83.8% +/- 4.9% at 1 month, 73.0% +/- 6.3% at 1 year, and 65.7% +/- 9.0% at 5 years after the operation. One patient had recurrence of endocarditis 6.7 months after the operation and required repeated homograft aortic root replacement. Reoperative aortic root replacement remains associated with a high postoperative mortality. The need to perform unplanned coronary artery bypass grafting during reoperative aortic root replacement is a major risk factor for hospital death. The optimal technique for coronary reconstruction in this setting remains to be debated.

  11. Surgical treatment of ascending aortic complications in Marfan syndrome: early and long-term outcomes.

    Science.gov (United States)

    Favaloro, Roberto R; Casabé, J Horacio; Segura, Mónica; Abud, José; Casas, Jorge; López, Claudio; Dulbecco, Eduardo; Raffaelli, Héctor

    2008-08-01

    Findings in 54 patients (mean age 39 years, range 18-66 years, 25% female) were analyzed. Of these patients, 21 had dissection of the ascending aorta (15 acute and six chronic) and 33 had aneurysm of the ascending aorta. Surgery was classified as emergency surgery in three cases, as urgent in 15, and as scheduled surgery in 36. The Bentall-De Bono procedure was performed in 39 patients, aortic valve reimplantation was carried out in nine, Cabrol's operation was performed in three, and a homograft was used in three. The mean diameter of the ascending aorta was 66.6 mm. Overall, in-hospital mortality was 3.7% (33.3% for emergency surgery vs. 2.8% for scheduled surgery; P< .001). During the mean follow-up period of 4 years (range, 2 months-14 years), seven patients died, including four who died due to type-B aortic dissection. The actuarial survival rate at 2, 5 and 10 years was 94%, 83% and 75%, respectively, with 88%, 67% and 43% of patients, respectively, not requiring reoperation. Elective aortic root replacement was associated with a low risk and a good survival rate.

  12. Endovascular Treatment of Two Pseudoaneurysms Originating From the Left Ventricle

    Energy Technology Data Exchange (ETDEWEB)

    Cwikiel, Wojciech, E-mail: wcwikiel@gmail.com; Keussen, Inger [Skane University Hospital, Department of Radiology (Sweden); Gustafsson, Ronny; Mokhtari, Arash [Skane University Hospital, Department of Thoracic Surgery (Sweden)

    2013-12-15

    A 67-year-old woman resented with an acute type A aortic dissection, which was treated surgically with aortic valve replacement as a composite graft with reimplantation of the coronary arteries. At the end of surgery, a left-ventricular venting catheter was placed through the apex and closed with a buffered suture. Consecutive computed tomography (CT) examinations verified a growing apex pseudoaneurysm. Communication between the ventricle and the pseudoaneurysm was successfully closed with an Amplatz septal plug by the transfemoral route. Follow-up CT showed an additional pseudoaneurysm, which also was successfully closed using the same method.

  13. Endovascular Treatment of Two Pseudoaneurysms Originating From the Left Ventricle

    International Nuclear Information System (INIS)

    Cwikiel, Wojciech; Keussen, Inger; Gustafsson, Ronny; Mokhtari, Arash

    2013-01-01

    A 67-year-old woman resented with an acute type A aortic dissection, which was treated surgically with aortic valve replacement as a composite graft with reimplantation of the coronary arteries. At the end of surgery, a left-ventricular venting catheter was placed through the apex and closed with a buffered suture. Consecutive computed tomography (CT) examinations verified a growing apex pseudoaneurysm. Communication between the ventricle and the pseudoaneurysm was successfully closed with an Amplatz septal plug by the transfemoral route. Follow-up CT showed an additional pseudoaneurysm, which also was successfully closed using the same method

  14. Modelling and numerical simulation of the in vivo mechanical response of the ascending aortic aneurysm in Marfan syndrome.

    Science.gov (United States)

    García-Herrera, Claudio M; Celentano, Diego J; Herrera, Emilio A

    2017-03-01

    Marfan syndrome (MFS) is a genetic disorder that affects connective tissue, impairing cardiovascular structures and function, such as heart valves and aorta. Thus, patients with Marfan disease have a higher risk of developing circulatory problems associated with mitral and aortic valves prolapse, manifested as dilated aorta and aortic aneurysm. However, little is known about the biomechanical characteristics of these structures affected with MFS. This study presents the modelling and simulation of the mechanical response of human ascending aortic aneurysms in MFS under in vivo conditions with intraluminal pressures within normotensive and hypertensive ranges. We obtained ascending aortic segments from five adults with MFS subjected to a vascular prosthesis implantation replacing an aortic aneurysm. We characterised the arterial samples via ex vivo tensile test measurements that enable fitting the material parameters of a hyperelastic isotropic constitutive model. Then, these material parameters were used in a numerical simulation of an ascending aortic aneurysm subjected to in vivo normotensive and hypertensive conditions. In addition, we assessed different constraints related to the movement of the aortic root. Overall, our results provide not only a realistic description of the mechanical behaviour of the vessel, but also useful data about stress/stretch-based criteria to predict vascular rupture. This knowledge may be included in the clinical assessment to determine risk and indicate surgical intervention.

  15. The imaging assessment and specific endograft design for the endovascular repair of ascending aortic dissection

    Directory of Open Access Journals (Sweden)

    Zhang Y

    2016-07-01

    Full Text Available Yepeng Zhang,1 Hanfei Tang,1 JianPing Zhou,2 Zhao Liu,1 Changjian Liu,1 Tong Qiao,1 Min Zhou1 1Department of Vascular Surgery, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 2Department of General Surgery, Yixin People’s Hospital, Yixin, People’s Republic of China Background: Endovascular option has been proposed for a very limited and selected number of Stanford type A aortic dissection (TAAD patients. We have performed a computed tomography (CT-based TAAD study to explore appropriate endograft configurations for the ascending aortic pathology. Methods: TAAD patients treated with optimal CT scans were retrospectively reviewed, and their entry tears (ETs were identified using three-dimensional and multiplanar reconstructions in an EndoSize workstation. After generating a centerline of flow, measurements, including numerous morphologic characteristics of anatomy, were evaluated and a selected subset of patients were determined to be suitable for endovascular treatments. Proximal diameter and distal diameter of endograft were selected based on diameters measured at the ET level and at the innominate artery (IA level, with 10% oversizing with respect to the true lumen, but not exceeding the original aortic diameter. The length of the endograft was determined by the distance from the sinotubular junction to IA. Results: This study covered 126 TAAD patients with primary ET in ascending aorta, among which, according to the assumed criteria, 48 (38.1% patients were deemed to be suitable for endovascular treatment. The diameters of ascending aorta from the sinotubular junction to the IA level presented a downward trend, and the proximal diameters differed significantly from distal diameters of the endograft for TAAD (39.9 versus 36.2 mm, P<0.01, implying that the conical endograft might be compatible with the ascending pathology. In the ascending aorta, lengths of the endograft should be 50, 60, 70, 80, and 90 mm in five

  16. Traditional Cardiovascular Risk Factors and Their Relation to Future Surgery for Valvular Heart Disease or Ascending Aortic Disease: A Case-Referent Study.

    Science.gov (United States)

    Ljungberg, Johan; Johansson, Bengt; Engström, Karl Gunnar; Albertsson, Elin; Holmer, Paul; Norberg, Margareta; Bergdahl, Ingvar A; Söderberg, Stefan

    2017-05-05

    Risk factors for developing heart valve and ascending aortic disease are based mainly on retrospective data. To elucidate these factors in a prospective manner, we have performed a nested case-referent study using data from large, population-based surveys. A total of 777 patients operated for heart valve disease or disease of the ascending aorta had previously participated in population-based health surveys in Northern Sweden. Median time (interquartile range) from survey to surgery was 10.5 (9.0) years. Primary indications for surgery were aortic stenosis (41%), aortic regurgitation (12%), mitral regurgitation (23%), and dilatation/dissection of the ascending aorta (17%). For each case, referents were allocated, matched for age, sex, and geographical area. In multivariable models, surgery for aortic stenosis was predicted by hypertension, high cholesterol levels, diabetes mellitus, and active smoking. Surgery for aortic regurgitation was associated with a low cholesterol level, whereas a high cholesterol level predicted surgery for mitral regurgitation. Hypertension, blood pressure, and previous smoking predicted surgery for disease of the ascending aorta whereas diabetes mellitus was associated with reduced risk. After exclusion of cases with coronary atherosclerosis, only the inverse associations between cholesterol and aortic regurgitation and between diabetes mellitus and disease of the ascending aorta remained. This is the first truly prospective study of traditional cardiovascular risk factors and their association with valvular heart disease and disease of the ascending aorta. We confirm the strong association between traditional risk factors and aortic stenosis, but only in patients with concomitant coronary artery disease. In isolated valvular heart disease, the impact of traditional risk factors is varying. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  17. An Unusual Left Ventricular Outflow Pseudoaneurysm: Usefulness of Echocardiography and Multidetector Computed Tomography for Surgical Repair

    International Nuclear Information System (INIS)

    Da Col, Uberto; Ramoni, Enrico; Di Bella, Isidoro; Ragni, Temistocle

    2009-01-01

    Left ventricular outflow tract (LVOT) pseudoaneurysm is a rare but potentially lethal complication, mainly after aortic root endocarditis or surgery. Usually it originates from a dehiscence in the mitral-aortic intervalvular fibrosa and it arises posteriorly to the aortic root. Due to these anatomical features, its imaging assessment is challenging and surgical repair requires complex procedures. An unusual case of LVOT pseudoaneurysm is described. It was detected by transthoracic ecocardiography 7 months after aortic root replacement for acute endocarditis. Multidetector computed tomography (MDCT) confirmed the presence of a pouch located between the aortic root and the right atrium. Computed tomography also detected the origin of the pseudoaneurysm from the muscular interventricular septum of the LVOT, rather below the aortic valve plane. It was repaired with an extracardiac surgical approach, sparing the aortic root bioprosthesis previously implanted. The high-resolution three-dimensional details provided by the preoperative MDCT allowed us to plan a simple and effective surgical strategy.

  18. Bentall procedure in ascending aortic aneurysm: hospital mortality.

    Science.gov (United States)

    Galicia-Tornell, Matilde Myriam; Marín-Solís, Bertha; Fuentes-Orozco, Clotilde; Martínez-Martínez, Manuel; Villalpando-Mendoza, Esteban; Ramírez-Orozco, Fermín

    2010-01-01

    Ascending aortic aneurysm disease (AAAD) shows a low frequency, heterogeneous behavior, high risk of rupture, dissection and mortality, making elective surgery necessary. Several procedures have been developed, and the Bentall technique is considered as the reference standard. The objective was to describe the hospital mortality of AAAD surgically treated using the Bentall procedure. We carried out a descriptive study. Included were 23 patients with AAAD who were operated on between March 1, 2005 and September 30, 2008 at our hospital. Data were obtained from clinical files, and descriptive statistics were selected for analysis. The study population was comprised of 23 patients with an average age of 46 years; 83% were males. Etiology was nonspecific degeneration of the middle layer with valve implication in 43%, bivalve aorta in 22%, Marfan syndrome, Turner's syndrome and poststenotic aneurysms each represented 9%, and Takayasu disease and ankylosing spondylitis 4% each. Associated heart disease was reported in six (26%) patients as follows: aortic coarctation (2), ischemic cardiopathy (1), atrial septal defect (1), severe mitral insufficiency (1) and subaortic membrane (1). Procedures carried out were Bentall surgery in 20 (87%) patients and aortoplasty with valve prosthesis in three (13%) patients. Complications reported were abnormal bleeding with mediastinal exploration (17%), nosocomial pneumonia (13%), arrhythmia (13%), and septic shock (9%). Mortality was reported in three (13%) patients due to septic shock and ventricular fibrillation. Surgical mortality with the Bentall procedure is similar to published results by other specialized centers. Events related to the basic aortic pathology, surgical technique, aortic valve prosthesis and left ventricular dysfunction encourage longterm studies with follow-up.

  19. Cine MRI of the ascending aorta in the elderly with respect to the flow signal void and aortic valve morphology

    International Nuclear Information System (INIS)

    Nakayama, Masafumi; Kyomasu, Yoshinori; Suzuki, Yasuko; Mashima, Yasuoki; Tanno, Munehiko; Endo, Kazuo; Yamada, Hideo

    1990-01-01

    Cine flow MRI was performed on a 1.5 Tesla system to observe signal intensity of blood flow within the ascending aorta in the elderly who had no aortic stenosis and to determine frequency of the flow signal void. Coronal and sagittal imaging planes of the ascending aorta were obtained in 27 aged patients with no known cardiac diseases (14 men and 13 women, mean age of 76) and 7 young volunteers (7 men, mean age of 24), utilizing ECG-gating, GRASS (gradient-recalled acquisition in steady state), and a flow compensation sequence. The young volunteers presented little or no signal void within the ascending aorta. In 26 (96%) of the 27 aged patients, on the other hand, signal void was demonstrated in the blood flow distal to the aortic valve during systole. The maximum length of the signal void that was measured at 318∼632 msec after the R wave of ECG ranged from 33 to 97 mm. Conventional and Doppler echocardiography was used to evaluate motion and morphology of the aortic valve in 19 of the 27 aged patients. Eighteen of these 19 subjects had aortic signal void on cine MRI. Echocardiography showed sclerotic changes of the aortic valve (i.e., increased echogenicity of the cusps and/or commissure fusion) in 10 (53%) of the 19 subjects. The mean maximum length of the signal void in the 10 patients with aortic valve sclerosis was significantly greater than that in the 9 patients with echocardiographically normal valve (68 vs.45 mm, p<0.01). These results suggest that signal void of blood flow in the ascending aorta, which is recognized as one of the characteristic findings in patients with aortic stenosis, is not a specific feature for this disease but rather a commom one in the elderly particularly those with sclerotic changes of the aortic valve. However, the length of the signal void may distinguish between nonstenotic and stenotic aortic valves. (author)

  20. Multiple Ascending Aortic Mural Thrombi and Acute Necrotizing Mediastinitis Secondary to Acute Pancreatitis

    Directory of Open Access Journals (Sweden)

    Byung Kwon Chong

    2016-10-01

    Full Text Available The formation of aortic thrombi is an extremely rare complication of acute pancreatitis. Here we report a case of acute pancreatitis complicated by a paraesophageal pseudocyst, necrotizing mediastinitis, and the formation of multiple thrombi in the ascending aorta. The patient was successfully treated by surgical therapy, which included extensive debridement of the mediastinum and removal of the aortic thrombi under cardiopulmonary bypass. Although esophageal resection was not carried out concomitantly, the lesions were resolved and the patient remained free of complications over 2 years of follow-up care.

  1. Retrograde Ascending Dissection After Thoracic Endovascular Aortic Repair Combined With the Chimney Technique and Successful Open Repair Using the Frozen Elephant Trunk Technique.

    Science.gov (United States)

    Hirano, Koji; Tokui, Toshiya; Nakamura, Bun; Inoue, Ryosai; Inagaki, Masahiro; Maze, Yasumi; Kato, Noriyuki

    2018-01-01

    The chimney technique can be combined with thoracic endovascular aortic repair (TEVAR) to both obtain an appropriate landing zone and maintain blood flow of the arch vessels. However, surgical repair becomes more complicated if retrograde type A aortic dissection occurs after TEVAR with the chimney technique. We herein report a case involving a 73-year-old woman who developed a retrograde ascending dissection 3 months after TEVAR for acute type B aortic dissection. To ensure an adequate proximal sealing distance, the proximal edge of the stent graft was located at the zone 2 level and an additional bare stent was placed at the left subclavian artery (the chimney technique) at the time of TEVAR. Enhanced computed tomography revealed an aortic dissection involving the ascending aorta and aortic arch. Surgical aortic repair using the frozen elephant trunk technique was urgently performed. The patient survived without stroke, paraplegia, renal failure, or other major complications. Retrograde ascending dissection can occur after TEVAR combined with the chimney technique. The frozen elephant trunk technique is useful for surgical repair in such complicated cases.

  2. Hybrid endovascular treatment of an aortic root and thoracoabdominal aneurysm in a high-risk patient with Marfan syndrome.

    Science.gov (United States)

    Gelpi, Guido; Mazzaccaro, Daniela; Romagnoni, Claudia; Contino, Monica; Antona, Carlo

    2013-05-01

    This report describes the hybrid endovascular treatment of an aortic root dilatation and a thoracoabdominal aneurysm in a high-risk patient with Marfan syndrome. A 50-year-old male, in hemodialysis for polycystic kidney and polycystic liver, was referred to our department for aortic root dilatation of 5 cm and a 6.3-cm thoracoabdominal aneurysm . He already underwent surgical repair of abdominal aortic aneurysm 10 years ago, complicated by pseudoaneurysm of the proximal anastomosis that had been treated in another center, with an endoprosthesis. The patient underwent aortic root replacement, aortic valve sparing operation, and rerouting of the superior mesenteric artery and celiac trunk to the ascending aorta. The thoracoabdominal aneurysm was excluded with an endoprosthesis few days after the surgical step. The 12-month computed tomography scan confirmed the complete exclusion of the thoracoabdominal aneurysm.

  3. Modified conduit preparation creates a pseudosinus in an aortic valve-sparing procedure for aneurysm of the ascending aorta.

    Science.gov (United States)

    Cochran, R P; Kunzelman, K S; Eddy, A C; Hofer, B O; Verrier, E D

    1995-06-01

    Mechanical valved conduit replacement of the aortic root is a durable and appropriate procedure for many diseases of the ascending aorta, but may sacrifice an anatomically salvageable aortic valve. For young active patients and for patients with "systemic" arterial disease (atherosclerosis, Marfan's syndrome) who may require future operations, life-long anticoagulation with its attendant thromboembolic versus hemorrhagic risks is not ideal. Several techniques have been suggested as aortic valve-sparing options. Recently, a procedure was described that combines the freehand homograft techniques with the standard Bentall techniques (David procedure). This innovative technique replaces the ascending aorta with a Dacron cylinder, spares the aortic valve, and restores competence and thus offers an excellent alternative. The durability of this procedure that places the aortic valve inside a cylindrical conduit without sinuses of Valsalva is unknown. In selected patients, we have used this technique to spare the aortic valve. On the basis of experimental data and preliminary computer modeling, with the hope of improving the durability, we have modified the conduit to create a "pseudosinus" in our most recent nine patients. We have done the David procedure in 10 patients. The pseudosinus modification was done in the most recent nine patients. Patients' ages ranged from 37 to 71 years (mean 49.9 years). There were five female and five male patients. Five patients had Marfan's syndrome and five patients had annuloaortic ectasia. There has been no mortality and all patients have had both early and late follow-up echocardiography. Five patients have zero to trace aortic insufficiency, four patients have trace to mild aortic insufficiency, and one patient has mild or "1+" aortic insufficiency. Aortic insufficiency has not progressed in any patient during the 18 months of follow-up. The patient with 1+ aortic insufficiency has no activity limits, good ventricular function, and

  4. Decreased expression of fibulin-4 in aortic wall of aortic dissection.

    Science.gov (United States)

    Huawei, P; Qian, C; Chuan, T; Lei, L; Laing, W; Wenlong, X; Wenzhi, L

    2014-02-01

    In this research, we will examine the expression of Fibulin-4 in aortic wall to find out its role in aortic dissection development. The samples of aortic wall were obtained from 10 patients operated for acute ascending aortic dissection and five patients for chronic ascending aortic dissection. Another 15 pieces of samples from patients who had coronary artery bypass were as controls. The aortic samples were stained with aldehyde magenta dyeing to evaluate the arrangement of elastic fibers. The Fibulin-4 protein and mRNA expression were both determined by Western blot and realtime quantitative polymerase chain reaction. Compared with the control group, both in acute and chronic ascending aortic dissection, elastic fiber fragments increased and the expression of fibulin-4 protein significantly decreased (P= 0.045 < 0.05). The level of fibulin-4 mRNA decreased in acute ascending aortic dissection (P= 0.034 < 0.05), while it increased in chronic ascending aortic dissection (P=0.004 < 0.05). The increased amounts of elastic fiber fragments were negatively correlated with the expression of fibulin-4 mRNA in acute ascending aortic dissection. In conclusion, in aortic wall of ascending aortic dissection, the expression of fibulin-4 protein decreased and the expression of fibulin-4 mRNA was abnormal. Fibulin-4 may play an important role in the pathogenesis of aortic dissection.

  5. Locally Different Endothelial Nitric Oxide Synthase Protein Levels in Ascending Aortic Aneurysms of Bicuspid and Tricuspid Aortic Valve

    Directory of Open Access Journals (Sweden)

    Salah A. Mohamed

    2012-01-01

    Full Text Available Aims. Dysregulated expression of the endothelial nitric oxide synthase (eNOS is observed in aortic aneurysms associated with bicuspid aortic valve (BAV. We determined eNOS protein levels in various areas in ascending aortic aneurysms. Methods and Results. Aneurysmal specimens were collected from 19 patients, 14 with BAV and 5 with tricuspid aortic valve (TAV. ENOS protein levels were measured in the outer curve (convexity, the opposite side (concavity, the distal and above the sinotubular junction (proximal aneurysm. Cultured aortic cells were treated with NO synthesis inhibitor L-NAME and the amounts of 35 apoptosis-related proteins were determined. In patients with BAV, eNOS levels were significantly lower in the proximal aorta than in the concavity and distal aorta. ENOS protein levels were also lower in the convexity than in the concavity. While the convexity and distal aorta showed similar eNOS protein levels in BAV and TAV patients, levels were higher in TAV proximal aorta. Inhibition of NO synthesis in aneurysmal aortic cells by L-NAME led to a cytosolic increase in the levels of mitochondrial serine protease HTRA2/Omi. Conclusion. ENOS protein levels were varied at different areas of the aneurysmal aorta. The dysregulation of nitric oxide can lead to an increase in proapoptotic HTRA2/Omi.

  6. Sinus of Valsalva Pseudoaneurysm as a Sequela to Infective Endocarditis.

    Science.gov (United States)

    Lee, Chin C; Siegel, Robert J

    2016-02-01

    Pseudoaneurysm is an uncommon sequela of infective endocarditis. We treated a 44-year-old man who had an active case of group B streptococcal infective endocarditis of the aortic valve despite no evidence of valvular dysfunction or vegetation on his initial transesophageal echocardiogram. After completing 6 weeks of intravenous antibiotic therapy, the patient developed a sinus of Valsalva pseudoaneurysm and severe aortic regurgitation caused by partial detachment of the left coronary cusp. We used a pericardial patch to close the pseudoaneurysm and repair the coronary cusp. This case shows the importance of routine clinical follow-up evaluation in infective endocarditis, even after completion of antibiotic therapy. Late sequelae associated with infective endocarditis or its therapy include recurrent infection, heart failure caused by valvular dysfunction (albeit delayed), and antibiotic toxicity such as aminoglycoside-induced nephropathy and vestibular toxicity.

  7. Analysis of autologous platelet-rich plasma during ascending and transverse aortic arch surgery.

    Science.gov (United States)

    Zhou, Shao-Feng; Estrera, Anthony L; Miller, Charles C; Ignacio, Craig; Panthayi, Sreelatha; Loubser, Paul; Sagun, Dean L; Sheinbaum, Roy; Safi, Hazim J

    2013-05-01

    Coagulopathy is a common complication after ascending and transverse arch aortic surgery with profound hypothermic circuit arrest (PHCA). Blood conservation strategies to reduce transfusion have been ongoing and involve multiple treatment modalities in modern cardiac surgery. The purpose of this study is to evaluate the effectiveness of autologous platelet-rich plasma (aPRP) as a blood conservation technique to reduce blood transfusion in ascending and arch aortic surgery. Between 2003 and 2009, we retrospectively reviewed 685 cases of ascending aorta and transverse arch repair using PHCA. A total of 287 patients in which aPRP was used (aPRP group) were compared with 398 patients who did have aPRP (non-aPRP group). Perioperative transfusion requirements and clinical outcomes that included early mortality, postoperative stroke, renal dysfunction, prolonged ventilation, coagulopathy, and length of postoperative intensive care unit stay were analyzed. The data were analyzed by mean and frequency for continuous variables and qualitative variables. To account for potential selection bias, 2 types of propensity analysis were performed. In both unadjusted and adjusted analysis, perioperative transfusions were fewer in the aPRP group compared with the non-aPRP group: (3.9 units fewer packed red blood cells, 4.5 units fewer fresh frozen plasma, 7.9 units fewer platelets, and 6.8 units fewer cryoprecipitate). In all analyses, postoperative morbidity (stroke, duration of mechanical ventilation, and intensive care unit stay) were significantly improved. Hospital mortality rate was not significantly decreased. The utilization of aPRP was associated with a reduction in allogeneic blood transfusions as well as a decrease in early postoperative morbidity during repairs of the ascending and transverse arch aorta using PHCA. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Dilatation of the ascending aorta is associated with presence of aortic regurgitation in patients after repair of tetralogy of Fallot

    Science.gov (United States)

    Ordovas, Karen Gomes; Keedy, Alexander; Naeger, David M.; Kallianos, Kimberly; Foster, Elyse; Liu, Jing; Saloner, David; Hope, Michael D.

    2016-01-01

    To evaluate the association between aortic morphology and elasticity with aortic regurgitation in surgically corrected of tetralogy of Fallot (TOF) patients. We retrospectively identified 72 consecutive patients with surgically corrected TOF and 27 healthy controls who underwent cardiac MRI evaluation. Velocity-encoded cine MRI was used to quantify degree of aortic regurgitation (AR) in TOF patients. Ascending aorta diameters were measured at standard levels on MRA images. Aortic pulse-wave velocity (PWV) was quantified with MRI. Morphological and functional MRI variables were compared between groups of TOF patients with and without clinically relevant AR and controls. The association between aortic morphology and elasticity with the presence of AR was evaluated using univariate and multivariate logistic regression. The majority of TOF patients had only trace AR. Nine TOF patients (12 %) had an AR fraction higher than 15 %. Indexed aorta diameter at the sinotubular junction (p = 0.007), at the RPA level (p = 0.006), and low left ventricular ejection fraction (LVEF) (p = 0.015) showed the strongest associations with the presence of at least mild AR, which persisted after controlling for age and gender. Increased ascending aorta dimension is associated with AR in patients after repair of TOF. LVEF was also low in the group of patients with relevant AR compared to those without, suggesting even mild to moderate AR may contribute to LV dysfunction in these patients. Enlarged ascending aorta may be an indication for precise quantification of regurgitant fraction with MRI, since symptomatic patients may need aortic valve repair when moderate regurgitation is present. PMID:27240599

  9. Ascending aortic aneurysm and diaphragmatic hernia in a case of Marfan syndrome.

    Science.gov (United States)

    Kothari, Jignesh; Hinduja, Manish; Baria, Kinnaresh; Pandya, Himani

    2017-06-01

    Marfan syndrome commonly affects the skeletal, ocular, and cardiovascular systems. Involvement of the gastrointestinal system is known but uncommon. Intervention depends upon the system involved and the severity of symptoms. Special awareness is required for the diagnosis and management of gastrointestinal involvement in these patients. We report a rare case of simultaneous surgical repair of an ascending aortic aneurysm and a type IV hiatal hernia in a 35-year-old man with Marfan syndrome.

  10. Mid-term results of zone 0 thoracic endovascular aneurysm repair after ascending aorta wrapping and supra-aortic debranching in high-risk patients.

    Science.gov (United States)

    Pecoraro, Felice; Lachat, Mario; Hofmann, Michael; Cayne, Neal S; Chaykovska, Lyubov; Rancic, Zoran; Puippe, Gilbert; Pfammatter, Thomas; Mangialardi, Nicola; Veith, Frank J; Bettex, Dominique; Maisano, Francesco; Neff, Thomas A

    2017-06-01

    Surgical repair of aneurysmal disease involving the ascending aorta, aortic arch and eventually the descending aorta is generally associated with significant morbidity and mortality. A less invasive approach with the ascending wrapping technique (WT), supra-aortic vessel debranching (SADB) and thoracic endovascular aneurysm repair (TEVAR) in zone 0 was developed to reduce the associated risk in these patients. During a 10-year period, consecutive patients treated by the ascending WT, SADB and TEVAR in zone 0 were included. All patients were considered at high risk for conventional surgery. Measured outcomes included perioperative deaths and morbidity, maximal aortic transverse diameter (TD) and its postoperative evolution, endoleak, survival, freedom from cardiovascular reinterventions, SADB freedom from occlusion and aortic valve function during follow-up. Median follow-up was 37.4 [mean = 34; range, 0-65; standard deviation (SD) = 20] months. Twenty-six cases were included with a mean age of 71.88 ( r  = 56-87; SD = 8) years. A mean of 2.9 supra-aortic vessels (75) per patient was debranched from the ascending aorta. The mean time interval from WT/SADB and TEVAR was 29 ( r  = 0-204; SD = 48) days. TEVAR was associated with chimney and/or periscope grafts in 6 (23%) patients, and extra-anatomical supra-aortic bypasses were performed in 6 (23%) patients. Perioperative mortality was 7.7% (2/26). Neurological events were registered in 3 (11.5%) cases, and a reintervention was required in 3 (11.5%) cases. After the WT, the ascending diameter remained stable during the follow-up period in all cases. At mean follow-up, significant shrinkage of the arch/descending aorta diameter was observed. A type I/III endoleak occurred in 3 cases. At 5 years, the rates of survival, freedom from cardiovascular reinterventions and SADB freedom from occlusion were 71.7, 82.3 and 96%, respectively. The use of the ascending WT, SADB and TEVAR in selected patients

  11. Valve-sparing root and ascending aorta replacement after heart transplantation.

    Science.gov (United States)

    Elhenawy, Abdelsalam M; Feindel, Christopher M; Ross, Heather; Butany, Jagdish; Yau, Terrence M

    2012-12-01

    A 45-year-old female underwent heart transplantation 17 years ago, with a heart from a 15-year-old donor. Recently, she had developed an aneurysm of the donor aortic root and ascending aorta, with severe aortic insufficiency. Two surgical options were considered; retransplantation versus replacement of the aortic root and ascending aorta. A valve-sparing replacement of the aortic root and ascending aortic aneurysm was performed. The donor aorta showed pathologic changes typical of Marfan syndrome. Nineteen months postoperatively, the patient remains in functional class I, with trivial aortic insufficiency. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  12. [Outcomes of endovascular repairing aortic arch disease hybrid with supra-arch debranching procedures].

    Science.gov (United States)

    Wang, Mian; Chang, Guangqi; Yin, Henghui; Yao, Chen; Wang, Jinsong; Wang, Shenming

    2015-11-01

    To summarize the experience of endovascular repairing aortic arch disease hybrid with supra-arch debranching procedures. It was a retrospective study. From January 2002 to December 2014, 42 high risk patients with aortic arch disease were treated by supra-arch debranching hybrid with subsequent endovascular repair in the First Affiliated Hospital of Sun Yat-sen University. There were 39 male and 3 female patients with a mean age of (53±13) years (ranging from 34 to 80 years). Of the 42 patients, 7 were thoracic aortic aneurysm, 20 were Stanford type B aortic dissection and 15 were Stanford type A aortic dissection. After the supra-aortic debranching technique, simultaneous (n=16) or staged (n=26, mean interval (7±3) days) endovascular repair were performed. Fisher exact test was used to compare the in-hospital mortality of ascending aorta based debranching and non-ascending aorta based debranching. Technical success rate was 81.0% (34/42). The overall 30-day complication rate was 31.0% (13/42), including 3 cerebral stroke (7.1%), 8 endoleak (19.0%, including 6 type I endoleak and 2 type II endoleak), 1 circulatory failure, 1 aorto-tracheal fistula. The 30-day mortality was 9.5% (4/42), 2 died of cerebral stroke, 1 died of circulatory failure, 1 died of aorto-tracheal fistula. The in-hospital mortality of ascending aorta based debranching group was obviously higher than that of the non-ascending aorta based debranching group (4/16 vs. 0, P=0.02). The median time of follow-up was 64.8 (2 to 156.9) months. CT scanning was performed at 1, 3 months after surgery and annually thereafter. The overall survival rate was 76.6%. During the follow-up period, there was 4 deaths, and 2 of them were aortic artery related (5.3%). There were 4 de novo complications during the follow-up period, 1 stroke attributed to bypass occlusion was cured by medical treatment, 2 pseudoaneurysm was successfully treated with open surgery, 1 stent-graft induced new distal entry tear was

  13. Hybrid treatment of bullet embolism at the abdominal aortic bifurcation, complicated with thoracoabdominal aorta pseudoaneurysm and common iliac artery occlusion: case report

    Directory of Open Access Journals (Sweden)

    Patrick Bastos Metzger

    2014-03-01

    Full Text Available Embolization due to a firearm projectile entering the bloodstream is a rare event that is unlikely to be suspected during initial treatment of trauma patients. We describe and discuss a case of bullet embolism of the abdominal aortic bifurcation, complicated by a pseudoaneurysm of the thoracoabdominal aorta and occlusion of the right common iliac artery, but successfully treated using a combination of endovascular methods and conventional surgery.

  14. Repeat Operation for Pseudoaneurysm of Left Ventricular Outflow in a Patient with Concomitant Takayasu’s Arteritis and Marfan Syndrome

    OpenAIRE

    Yamashiro, Satoshi; Kuniyoshi, Yukio; Arakaki, Katsuya; Nagano, Takaaki; Kise, Yuya

    2011-01-01

    We describe concomitant Marfan syndrome and Takayasu’s arteritis complicating a pseudoaneurysm of the left ventricular outflow that developed after aortic root reconstruction. A patient was admitted with a high fever four months after initial root reconstruction that included valve sparing (reimplantation) as well as coronary artery reconstruction using a Carrel’s button technique. Computed tomography revealed a pseudoaneurysm at the posterior side of the aortic root. We applie...

  15. Multidrug Resistant Pseudomonas Mycotic Pseudoaneurysm following Cardiac Transplant Bridged by Ventricular Assistant Device

    Directory of Open Access Journals (Sweden)

    C. Aye

    2017-01-01

    Full Text Available Mycotic pseudoaneurysm of aorta following cardiac surgery is rare but is highly fatal if it is unrecognized and untreated. Here, we report a case of a 45-year-old male patient who presented with rapidly progressive multiple pseudoaneurysms of the ascending aorta infected with multidrug resistant (MDR Pseudomonas aeruginosa at 5 weeks after cardiac transplantation, on a background of prior bridging therapy with left ventricular assistant device (LVAD. The patient was successfully treated with the newer cephalosporin, Ceftolozane/Tazobactam, in combination with surgery. This is the first reported case of mycotic pseudoaneurysm infected with MDR Pseudomonas. This case also highlights the importance of high vigilance and timely multimodality treatment in the diagnosis and management of mycotic pseudoaneurysm following cardiac transplant, especially in patients who had LVAD.

  16. Moderate versus deep hypothermic circulatory arrest for ascending aorta and aortic arch surgeries using open distal anastomosis technique

    Directory of Open Access Journals (Sweden)

    Ahmed Abdelgawad

    2017-12-01

    Conclusions: MHCA with ACP achieved very good and comparable results to DHCA with RCP for ascending and aortic reconstruction. Furthermore, MHCA significantly shortened total operative, cardiopulmonary bypass and ischaemic times and, basically, decreased transfusion requirements compared with the former strategy and consequently may lead to better patient's outcome.

  17. In vivo 3-dimensional Magnetic Resonance Wall Shear Stress Estimation in Ascending Aortic Dilatation

    Science.gov (United States)

    Bieging, Erik T.; Frydrychowicz, Alex; Wentland, Andrew; Landgraf, Benjamin R.; Johnson, Kevin M.; Wieben, Oliver; François, Christopher J.

    2011-01-01

    Purpose To estimate surface-based wall shear stress (WSS) and evaluate flow patterns in ascending aortic dilatation (AscAD) using a high-resolution, time-resolved, three-dimensional (3D), three-directional velocity encoded, radially undersampled phase contrast magnetic resonance sequence (4D PC-MRI). Materials and Methods 4D PC-MRI was performed in 11 patients with AscAD (46.3±22.0 years) and 10 healthy volunteers (32.9±13.4 years) after written informed consent and IRB-approval. Following manual vessel wall segmentation of the ascending aorta (MATLAB, The Mathworks, Natick, MA), a 3D surface was created using spline interpolation. Spatial WSS variation based on surface division in 12 segments and temporal variation were evaluated in AscAD and normal aortas. Visual analysis of flow patterns was performed based on streamlines and particle traces using EnSight (v9.0, CEI, Apex, NC). Results AscAD was associated with significantly increased diastolic WSS, decreased systolic to diastolic WSS ratio, and delayed onset of peak WSS (all P wall of the ascending aorta. Vortical flow with highest velocities along the anterior wall and increased helical flow during diastole were observed in AscAD compared to controls. Conclusion Changes in WSS in the ascending aorta of AscAD correspond to observed alterations in flow patterns compared to controls. PMID:21563242

  18. Pathogenetic Basis of Aortopathy and Aortic Valve Disease

    Science.gov (United States)

    2018-02-19

    Aortopathies; Thoracic Aortic Aneurysm; Aortic Valve Disease; Thoracic Aortic Disease; Thoracic Aortic Dissection; Thoracic Aortic Rupture; Ascending Aortic Disease; Descending Aortic Disease; Ascending Aortic Aneurysm; Descending Aortic Aneurysm; Marfan Syndrome; Loeys-Dietz Syndrome; Ehlers-Danlos Syndrome; Shprintzen-Goldberg Syndrome; Turner Syndrome; PHACE Syndrome; Autosomal Recessive Cutis Laxa; Congenital Contractural Arachnodactyly; Arterial Tortuosity Syndrome

  19. Intra-operative Vector Flow Imaging Using Ultrasound of the Ascending Aorta among 40 Patients with Normal, Stenotic and Replaced Aortic Valves

    DEFF Research Database (Denmark)

    Hansen, Kristoffer Lindskov; Møller-Sørensen, Hasse; Kjaergaard, Jesper

    2016-01-01

    Stenosis of the aortic valve gives rise to more complex blood flows with increased velocities. The angleindependent vector flow ultrasound technique transverse oscillation was employed intra-operatively on the ascending aorta of (I) 20 patients with a healthy aortic valve and 20 patients with aor...... replacement corrects some of these changes. Transverse oscillation may be useful for assessment of aortic stenosis and optimization of valve surgery. (E-mail: lindskov@gmail.com) 2016 World Federation for Ultrasound in Medicine & Biology...... with aortic stenosis before (IIa) and after (IIb) valve replacement. The results indicate that aortic stenosis increased flow complexity (p , 0.0001), induced systolic backflow (p , 0.003) and reduced systolic jet width (p , 0.0001). After valve replacement, the systolic backflow and jet width were normalized...

  20. Impact of surgical era on outcomes of patients undergoing elective atherosclerotic ascending aortic aneurysm operations.

    Science.gov (United States)

    Fleck, Tatiana M; Koinig, Herbert; Czerny, Martin; Hutschala, Doris; Wolner, Ernst; Ehrlich, Marek; Grabenwoger, Martin

    2004-08-01

    This retrospective study evaluates, if recent refinements in peri-operative management, have an impact on clinical outcome of patients undergoing elective repair of their ascending thoracic aorta. One hundred sixty five (n = 165) consecutive patients were operated during a 7 year period at our department. The cohort was divided in an early group I (from Jan 1997 to Dec 1999, n = 75) and a late group II (from Jan 2000 to Jan 2003, n = 90). The mean age was 60.9+/-13.1 years in group I versus 58.1+/-13.6 years in group II. In group I 50 patients (66.6%) underwent replacement of the ascending thoracic aorta alone, 17 patients (22.6%) received a composite graft, 8 patients (10.6%) had an additional aortic valve replacement and 14 patients (18.6%) needed concomitant coronary artery bypass grafting. In group II the procedures were as follows: interposition graft alone in 58 patients (64.4%), composite graft in 26 patients (28.8%), aortic valve replacement in 6 (6.6%) and CABG in 11 patients (12.2%). Overall hospital mortality for the entire cohort was 6.6% (11/165) with no significant differences between the early and late group with 6.6% (5/75) and 6.6% (6/90), respectively, P = 0.985. Causes were multi organ failure in 63.3% (n = 7), stroke in 9% (n = 1) myocardial infarction in 18.1% (n = 2) and refractory bleeding in 9% (n = 1). Concomitant CABG, repair of the aortic valve and composite graft, emerged as independent risk factor for mortality in multivariate logistic regression analysis with P = 0.001. Differences, became apparent in ICU as well as hospital stay with a median ICU stay in group I of 7.1+/-12.9 days versus 4.4+/-6.8 days in group II, and median hospital stay of 16.7+/-5.3 days versus 9.5+/-8.4 days for group I and II, P conservation techniques, a substantial reduction of transfusion requirements could be achieved (PRBC from 3.2+/-4 to 1.1+/-1.7 units, FFP 5.2+/-3 to 2.3+/-0.5 units, Platelets from 1.3+/-2 to 0.3+/-0.07 units). Even with the

  1. Spontaneous Superior Mesenteric Artery Branch Pseudoaneurysm: A Rare Case Report

    Directory of Open Access Journals (Sweden)

    Mina Guirgis

    Full Text Available : Background: Visceral arterial pseudoaneurysms (VAPAs are rare vascular entities with serious consequences. Traditionally, they are associated with trauma, infection, and inflammatory disease, or they can arise as a post-operative complication. Report: An 87 year old man presented with abdominal pain and was found to have a spontaneous VAPA on a computed tomography angiogram. Serial imaging 4 months previously had demonstrated no aneurysm. Between scans, warfarin was changed to apixaban for aortic valve replacement, but he had no other changes to any other medications. He required urgent endovascular coiling of the pseudoaneurysm, with satisfactory recovery and outcome. Discussion: VAPAs are extremely rare, with splenic artery VAPAs the most commonly reported. Regardless, fewer than 250 cases of splenic artery pseudoaneurysm have been reported. Superior mesenteric artery (SMA pseudoaneurysms are the rarest type of VAPAs. Early identification and urgent treatment are warranted because of the associated high mortality risk, with a 50% risk of rupture in any given VAPA. Treatment options range from open operation to endoscopic and endovascular procedures. Apixaban has been proposed to contribute to pseudoaneurysm formation by slow and continuous bleeding that results in the formation of the pseudoaneurysm. Conclusions: Spontaneous VAPAs are extremely rare and this is the first time a VAPA has been associated with the novel oral anticoagulant “apixaban”. Urgent management of any VAPAs is important because of the high risk of rupture and potential life threatening haemorrhage. Keywords: Visceral arterial pseudoaneurysm, Superior mesenteric artery, Apixaban, Coils

  2. A correlative study of aortic valve rotation angle and thoracic aortic sizes using ECG gated CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Saremi, Farhood, E-mail: fsaremi@usc.edu; Cen, Steven; Tayari, Nazila; Alizadeh, Houman; Emami, Amir; Lin, Leah; Fleischman, Fernando

    2017-04-15

    Objective: Various degrees of aortic valve rotation may be seen in individuals with no history of congenital cardiovascular malformations, but its association with aortic sizes has not been studied. Methods: Gated computed tomographic (CT angiograms in 217 patients were studied (66.7 ± 15; 22–97 years old)). Aortic diameters were determined at 5 anatomic locations. The length of the aorta from sinus to left subclavian artery was measured. The angle of valve rotation was recorded by measuring the angle between a line connecting the midpoint of the non-coronary sinus to the anterior commissure and another line along the interatrial septum. Rotation angles were correlated with aortic measurements. Patients were separated into two groups based on aortic sizes and into three groups based on age. The threshold for aortic dilatation was set at maximum ascending aorta diameter ≥40 mm (≥21 mm body surface area [BSA] indexed). Results: No significant difference in rotation angles was seen between the three age groups or between genders. Rotation angles were significantly correlated with maximal, average, and BSA adjustment of the aortic root and ascending aortic measurements. The aortic root angles were significantly different between the dilated versus nondilated aortas. There was no significant association between the rotation angles and age, length of ascending aorta, or diameters of descending aorta. Multivariate adaptive regression splines showed 25° of aortic root rotation as the diagnostic cut off for ascending aorta dilation. Above the 25° rotation, every 10° of increasing rotation was associated with a 3.78 ± 0.87 mm increase in aortic diameter (p < 0.01) and a 1.73 ± 0.25 times increased risk for having a dilated aorta (p < 0.01). Conclusion: Rotation angles of the aortic valve may be an independent non-invasive imaging marker for dilatation of the ascending aorta. Patients with increased rotation angle of the aortic valve may have higher risk for

  3. Blood conservation strategies reduce the need for transfusions in ascending and aortic arch surgery.

    Science.gov (United States)

    Chu, M W A; Losenno, K L; Moore, K; Berta, D; Hewitt, J; Ralley, F

    2013-07-01

    Ascending and aortic arch surgery is associated with higher levels of blood loss and subsequent need for allogeneic blood transfusions. We hypothesized that aggressive, comprehensive blood conservation strategies may limit the need for transfusions and, subsequently, improve postoperative outcomes. Over a five-year period, 189 patients underwent proximal aortic surgery at our institution. Fifty-one patients underwent surgery using a comprehensive blood conservation strategy (BCS), including preoperative hemoglobin optimization, antifibrinolytic therapy, intraoperative acute normovolemic hemodilution, cell salvage and meticulous surgical technique. The remaining 138 patients underwent surgery using conventional techniques (CONV). Patients in the BCS group required fewer transfusions during their hospital stay compared to the conventional group (56.9% vs. 72.5%, p=0.041). When examining elective cases, this trend widens, with 40.0% of BCS patients requiring any transfusions compared to 72.9% patients in the conventional group (p=0.001). Red cell (47.1% vs. 62.3%, p=0.06), plasma (43.1% vs. 61.6%, p=0.02) and platelets (27.5% vs. 47.8%, p=0.01) were also less frequently required in the BCS group than the conventional group, respectively. When a transfusion was required, patients in the BCS group received significantly fewer units of red blood cells (2.8 ± 7.0 units) than the conventional group (5.81 ± 9.5 units; p=0.039). Mortality was similar in both groups (BCS 7.8%, conventional 10.9%, p=0.54); however, there was significantly less morbidity in the BCS group, using a composite of any of 10 major postoperative complications (23.5% vs. 39.1%; p=0.046). Median intensive care unit (ICU) and hospital lengths of stay were 2 and 7 days in the BCS group and 2 and 8 days in the CONV group (p=0.15), respectively. The aggressive use of a comprehensive blood conservation strategy in ascending and aortic arch surgery can significantly reduce the need for blood transfusions

  4. Anesthetic Implications of Emergent Cesarean Section in a Parturient with Marfan Syndrome Complicated by Ascending Aortic Aneurysm and Heart Failure

    Directory of Open Access Journals (Sweden)

    Young Sung Kim

    2014-07-01

    Full Text Available Cardiovascular comorbidities to the Marfan syndrome may induce hemodynamic instability especially in the parturients during labor or delivery. For anesthesiologists, it is challenging to maintain hemodynamic stability during Cesarean section in those patients with Marfan syndrome. Remifentanil is an ultra-short-acting opioid with rapid onset and offset of action which provides cardiovascular stability during surgery. Together with remifentanil, the use of a laryngeal mask airway can reduce the risk of hypertensive response followed by tracheal intubation. We describe the successful administration of remifentanil and application of laryngeal mask airway for emergent Cesarean section performed under general anesthesia in a patient with Marfan syndrome complicated by ascending aortic aneurysm and heart failure. The use of remifentanil (loading dose of 1 μg/kg for 1 min, 2 min before induction; thereafter continuous infusion dose of 0.1 μg/kg/min was useful to maintain hemodynamic stability of the parturient throughout the surgery without neonatal respiratory depression. Keywords: Ascending Aortic Aneurysm; Cesarean section; Laryngeal mask airway; Marfan syndrome; Remifentanil

  5. Aortic elongation in aortic aneurysm and dissection: the Tübingen Aortic Pathoanatomy (TAIPAN) project.

    Science.gov (United States)

    Krüger, Tobias; Sandoval Boburg, Rodrigo; Lescan, Mario; Oikonomou, Alexandre; Schneider, Wilke; Vöhringer, Luise; Lausberg, Henning; Bamberg, Fabian; Blumenstock, Gunnar; Schlensak, Christian

    2018-01-24

    To study the lengths and diameters of aortic segments in healthy and diseased aortas and to assess the role of aortic elongation in Type A aortic dissection (TAD) prediction. Ectasia and aneurysm were defined by ascending aorta diameters of 45-54 mm and ≥55 mm, respectively. Computed tomography angiography studies of 256 healthy, 102 ectasia, 38 aneurysm, 17 pre-TAD and 166 TAD aortas were analysed using curved multiplanar reformats. The study groups were structurally equal. The diameter of the ascending aorta was 35 mm in the control group and was larger (P TAD (43 mm) and TAD (56 mm) groups. The length of the ascending aorta from the aortic annulus to the brachiocephalic trunk was 92 mm in the control group, 113 mm in the ectasia group, 120 mm in the aneurysm group and 111 mm and 118 mm in the pre-TAD and TAD groups (all P TAD group and 48% of the TAD group. The correlation between the diameter and the length of the ascending aorta was r = 0.752; therefore, both parameters must be examined separately. A score considering both parameters identified 23.5% of pre-TAD patients, significantly more than the diameter alone, and 31.4% of ectasia aortas were elongated. Patients with ectatic (45-54 mm diameter) and elongated (≥120 mm) ascending aortas represent a high-risk subpopulation for TAD. © The Author(s) 2018. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  6. Treatment of pseudoaneurysms with stent-graft: preliminary experience in 12 cases

    International Nuclear Information System (INIS)

    Liao Denghui; Ye Caisheng; Li Songqi; Ye Runyi; Chang Guangqi; Chen Wei; Li Xiaoxi; Wang Shenming

    2012-01-01

    Objective: To asses the clinical effect of stent-graft in the treatment of pseudoaneurysms. Methods: During the period from March 2008 to June 2011, 86 patients with pseudoaneurysms were admitted to the hospital, of whom stent-graft implantation was carried out in 12. The pseudoaneurysms were located at the thoracic aorta (n=4), abdominal aorta (n=3), common carotid artery (n=3), internal carotid artery (n=1) and right subclavian artery (n=1). All the patient were followed up for 5-43 months. The clinical results were analyzed. Results: The technical success rate for stent delivery was 100%. The pseudoaneurysms was immediately isolated after the procedure in all 12 cases. After endovascular exclusion with stent-graft, no leakage occurred and the blood flow distal to the parent artery was normal. All patients were followed up for a mean period of 23.5 months except one who lost in touch with the authors. One patient with coexisting Behcet's disease died of massive bleeding due to abdominal aortic rupture four months after operation. The other patients were in good clinical condition, and no complications such as stent stenosis, displacement, internal leakage etc. were observed in the follow-up period. Conclusion: The implantation of stent-graft has satisfactory short-term effect in treating pseudoaneurysms, although its long-term efficacy needs to be further observed. (authors)

  7. Aortic Root Replacement for Children With Loeys-Dietz Syndrome.

    Science.gov (United States)

    Patel, Nishant D; Alejo, Diane; Crawford, Todd; Hibino, Narutoshi; Dietz, Harry C; Cameron, Duke E; Vricella, Luca A

    2017-05-01

    Loeys-Dietz syndrome (LDS) is an aggressive aortopathy with a proclivity for aortic aneurysm rupture and dissection at smaller diameters than other connective tissue disorders. We reviewed our surgical experience of children with LDS to validate our guidelines for prophylactic aortic root replacement (ARR). We reviewed all children (younger than 18 years) with a diagnosis of LDS who underwent ARR at our institution. The primary endpoint was mortality, and secondary endpoints included complications and the need for further interventions. Thirty-four children with LDS underwent ARR. Mean age at operation was 10 years, and 15 (44%) were female. Mean preoperative root diameter was 4 cm. Three children (9%) had composite ARR with a mechanical prosthesis, and 31 (91%) underwent valve-sparing ARR. Concomitant procedures included arch replacement in 2 (6%), aortic valve repair in 1 (3%), and patent foramen ovale closure in 16 (47%). There was no operative mortality. Two children (6%) required late replacement of the ascending aorta, 5 (15%) required arch replacement, 1 (3%) required mitral valve replacement, and 2 (6%) had coronary button aneurysms/pseudoaneurysms requiring repair. Three children required redo valve-sparing ARR after a Florida sleeve procedure, and 2 had progressive aortic insufficiency requiring aortic valve replacement after a valve-sparing procedure. There were 2 late deaths (6%). These data confirm the aggressive aortopathy of LDS. Valve-sparing ARR should be performed when feasible to avoid the risks of prostheses. Serial imaging of the arterial tree is critical, given the rate of subsequent intervention. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Aortic root reimplantation procedure: a new milestone in aortic valve-sparing operations

    Directory of Open Access Journals (Sweden)

    А. М. Чернявский

    2016-08-01

    Full Text Available Aim: Emphasis in this study was placed on clinical and functional assessment of a modified "Florida Sleeve" procedure during surgical correction of ascending aorta aneurysms with concomitant aortic insufficiency.Methods: 32 patients with an aneurysm of the ascending aorta and aortic insufficiency underwent a modified "Florida Sleeve" procedure. The average follow-up was 17 (0-60 months. The average age of patients was 57±13 (23-73 years 56±13 years.Results: The expected 4-year cumulative survival rate was 84.3%. Overall freedom from aortic insufficiency in the late period was 88.9%. Median aortic regurgitation was 1+ (1; 2. Long-term follow-up revealed no valve-associated complications.Conclusion: The aortic root reimplantation procedure enables optimal correction of the existing lesions of the aortic root without performing aortic valve replacement and demonstrates stable clinical and functional outcomes in the long-term period.Key words: aortic aneurysm; aortic valve; valve-sparing operations.FundingThe study had no sponsorship.Conflict of interestThe authors declare no conflict of interest.

  9. Repeat Operation for Pseudoaneurysm of Left Ventricular Outflow in a Patient with Concomitant Takayasu's Arteritis and Marfan Syndrome.

    Science.gov (United States)

    Yamashiro, Satoshi; Kuniyoshi, Yukio; Arakaki, Katsuya; Nagano, Takaaki; Kise, Yuya

    2011-01-01

    We describe concomitant Marfan syndrome and Takayasu's arteritis complicating a pseudoaneurysm of the left ventricular outflow that developed after aortic root reconstruction. A patient was admitted with a high fever four months after initial root reconstruction that included valve sparing (reimplantation) as well as coronary artery reconstruction using a Carrel's button technique. Computed tomography revealed a pseudoaneurysm at the posterior side of the aortic root. We applied a modified Bentall procedure including coronary artery reconstruction using the Piehler technique. Pathological assessment of a specimen of the aorta revealed no central medial necrosis, but significant lymphocytic infiltration and thick fibrous adventitia indicating Takayasu's arteritis. This case was unique in terms of having simultaneous Takayasu's arteritis and cardiovascular manifestations of Marfan syndrome that were surgically treated.

  10. Valve-sparing aortic root replacement and aortic valve repair in a patient with acromegaly and aortic root dilatation

    Directory of Open Access Journals (Sweden)

    Karel Van Praet

    2015-07-01

    Full Text Available Aortic regurgitation and dilatation of the aortic root and ascending aorta are severe complications of acromegaly. The current trend for management of an aortic root aneurysm is valve-sparing root replacement as well as restoring the diameter of the aortic sinotubular junction (STJ and annulus. Our case report supports the recommendation that in patients with acromegaly, severe aortic root involvement may indicate the need for surgery.

  11. Long-Term Risk for Aortic Complications After Aortic Valve Replacement in Patients With Bicuspid Aortic Valve Versus Marfan Syndrome.

    Science.gov (United States)

    Itagaki, Shinobu; Chikwe, Joanna P; Chiang, Yuting P; Egorova, Natalia N; Adams, David H

    2015-06-09

    Bicuspid aortic valves are associated with valve dysfunction, ascending aortic aneurysm and dissection. Management of the ascending aorta at the time of aortic valve replacement (AVR) in these patients is controversial and has been extrapolated from experience with Marfan syndrome, despite the absence of comparative long-term outcome data. This study sought to assess whether the natural history of thoracic aortopathy after AVR in patients with bicuspid aortic valve disease is substantially different from that seen in patients with Marfan syndrome. In this retrospective comparison, outcomes of 13,205 adults (2,079 with bicuspid aortic valves, 73 with Marfan syndrome, and 11,053 control patients with acquired aortic valve disease) who underwent primary AVR without replacement of the ascending aorta in New York State between 1995 and 2010 were compared. The median follow-up time was 6.6 years. The long-term incidence of thoracic aortic dissection was significantly higher in patients with Marfan syndrome (5.5 ± 2.7%) compared with those with bicuspid valves (0.55 ± 0.21%) and control group patients (0.41 ± 0.08%, p Marfan syndrome (10.8 ± 4.4%) compared with those with bicuspid valves (4.8 ± 0.8%) and control group patients (1.4 ± 0.2%) (p Marfan syndrome were significantly more likely to undergo thoracic aortic surgery in late follow-up (10.4 ± 4.3%) compared with those with bicuspid valves (2.5 ± 0.6%) and control group patients (0.50 ± 0.09%) (p Marfan syndrome compared with those with bicuspid aortic valves confirm that operative management of patients with bicuspid aortic valves should not be extrapolated from Marfan syndrome and support discrete treatment algorithms for these different clinical entities. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  12. Autologous platelet-rich plasma reduces transfusions during ascending aortic arch repair: a prospective, randomized, controlled trial.

    Science.gov (United States)

    Zhou, Shao Feng; Estrera, Anthony L; Loubser, Paul; Ignacio, Craig; Panthayi, Sreelatha; Miller, Charles; Sheinbaum, Roy; Safi, Hazim J

    2015-04-01

    Blood conservation using autologous platelet-rich plasma (aPRP), a technique of whole blood harvest that separates red blood cells from plasma and platelets before cardiopulmonary bypass with retransfusion of the preserved platelets after completion of cardiopulmonary bypass, has not been studied extensively. We sought to prospectively determine whether aPRP reduces blood transfusions during ascending and transverse aortic arch repair. We randomly assigned 80 patients undergoing elective ascending and transverse aortic arch repair using deep hypothermic circulatory arrest to receive either aPRP (n = 38) or no aPRP (n = 42). Volume of aPRP retransfused was 726 ± 124 mL. The primary end point was transfusion amount. Secondary end points were death, stroke, renal failure, pulmonary failure, and transfusion costs. Perioperative transfusion rate was defined as blood transfusions given during surgery and up to 72 hours afterward. The surgeon and intensivist were blinded to the treatment arm. Because an anesthesiologist initiated the protocol, the surgeon was not aware of aPRP collection, as this occurred only after the sterile drape was in place. In addition, because cell salvage was performed on all cases, differentiation in perfusionist activities (during spinning of aPRP) was not evident. Platelet, fresh frozen plasma, and cryoprecipitate intraoperative transfusions were performed only after heparin was reversed and the patient was judged as coagulopathic on the basis of associated criteria: cryoprecipitate transfusion for fibrinogen level less than 150 μg/dL, platelet transfusion for platelet count less than 80,000, and fresh frozen plasma when thromboelastogram test was suggestive or a partial thromboplastin time was greater than 55 seconds, and prothrombin time was greater than 1.6 seconds. Early mortality, stroke, and respiratory complications were similar between groups. Only acute renal failure was reduced in the aPRP group, 7% versus 0% (p platelets by 56

  13. Real chimney technique for total debranching of supra-aortic trunks.

    Science.gov (United States)

    Kato, Masaaki; Kagaya, Hideo; Kubo, Yoji; Banno, Hiroshi; Ohkubo, Nobukazu

    2015-02-01

    Side-clamping of the ascending aorta is an indispensable technique for proximal anastomosis in total debranching of supra-aortic trunks and in endovascular aneurysm repair for arch aneurysm. However, this procedure may lead to the dislodging of multiple plaques and to clamp injury of the ascending aorta. We developed a clampless technique to achieve proximal anastomosis between the ascending aorta and an artificial graft used for total debranching of supra-aortic trunks. We applied this method in six patients with arch aneurysm and a plaque-rich ascending aorta and were able to achieve total debranching of the supra-aortic trunks in all of the patients without side-clamping the ascending aorta and no procedurally related complications. This clampless anastomosis technique ("real chimney technique") in the ascending aorta is a valuable option for total debranching of supra-aortic trunks in the hybrid repair of arch aneurysms. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  14. The thoracic aortography by Gd-DTPA enhanced ultrafast cine MR imaging. Assessment of thoracic aortic dilatation in aging and in patients with hypertension and aortic valve disease

    International Nuclear Information System (INIS)

    Matsumura, Kentaro; Nakase, Emiko; Kawai, Ichiyoshi; Saito, Takayuki; Kikkawa, Nobutada; Haiyama, Toru

    1995-01-01

    To assess the morphology of thoracic aorta, we had a trial of Gd-DTPA enhanced ultrafast cine MR imaging on the thoracic aorta. This method was provided with high quality thoracic aortogram during 15-20 seconds. In patients without hypertension and aortic valve disease, dimensions of ascending aorta and aortic arch were significantly correlated with aging. In patients with hypertension, dimensions of ascending aorta and aortic arch were significantly dilated. In patients with aortic valve disease, thoracic aorta was diffusely enlarged, especially in ascending aorta. Gd-DTPA enhanced ultrafact cine MR imaging was useful to assess the thoracic aortic anatomy and diseases. (author)

  15. Repeat Operation for Pseudoaneurysm of Left Ventricular Outflow in a Patient with Concomitant Takayasu’s Arteritis and Marfan Syndrome

    Science.gov (United States)

    Yamashiro, Satoshi; Kuniyoshi, Yukio; Arakaki, Katsuya; Nagano, Takaaki; Kise, Yuya

    2011-01-01

    We describe concomitant Marfan syndrome and Takayasu’s arteritis complicating a pseudoaneurysm of the left ventricular outflow that developed after aortic root reconstruction. A patient was admitted with a high fever four months after initial root reconstruction that included valve sparing (reimplantation) as well as coronary artery reconstruction using a Carrel’s button technique. Computed tomography revealed a pseudoaneurysm at the posterior side of the aortic root. We applied a modified Bentall procedure including coronary artery reconstruction using the Piehler technique. Pathological assessment of a specimen of the aorta revealed no central medial necrosis, but significant lymphocytic infiltration and thick fibrous adventitia indicating Takayasu’s arteritis. This case was unique in terms of having simultaneous Takayasu’s arteritis and cardiovascular manifestations of Marfan syndrome that were surgically treated. PMID:23555475

  16. Computerized tomographic evaluation of aortic prosthetic graft complications

    International Nuclear Information System (INIS)

    Kay, D.; Kalmar, J.A.

    1985-01-01

    Computerized tomography has been found to be an accurate and sensitive method of diagnosing complications of synthetic aortic grafts. Complications in this series of four cases included aortoesophageal fistula, aortoduodenal fistula, pseudoaneurysm, and retroperitoneal hematoma. 6 references, 5 figures

  17. Computational predictions of damage propagation preceding dissection of ascending thoracic aortic aneurysms.

    Science.gov (United States)

    Mousavi, S Jamaleddin; Farzaneh, Solmaz; Avril, Stéphane

    2018-04-01

    Dissections of ascending thoracic aortic aneurysms (ATAAs) cause significant morbidity and mortality worldwide. They occur when a tear in the intima-media of the aorta permits the penetration of the blood and the subsequent delamination and separation of the wall in 2 layers, forming a false channel. To predict computationally the risk of tear formation, stress analyses should be performed layer-specifically and they should consider internal or residual stresses that exist in the tissue. In the present paper, we propose a novel layer-specific damage model based on the constrained mixture theory, which intrinsically takes into account these internal stresses and can predict appropriately the tear formation. The model is implemented in finite-element commercial software Abaqus coupled with user material subroutine. Its capability is tested by applying it to the simulation of different exemplary situations, going from in vitro bulge inflation experiments on aortic samples to in vivo overpressurizing of patient-specific ATAAs. The simulations reveal that damage correctly starts from the intimal layer (luminal side) and propagates across the media as a tear but never hits the adventitia. This scenario is typically the first stage of development of an acute dissection, which is predicted for pressures of about 2.5 times the diastolic pressure by the model after calibrating the parameters against experimental data performed on collected ATAA samples. Further validations on a larger cohort of patients should hopefully confirm the potential of the model in predicting patient-specific damage evolution and possible risk of dissection during aneurysm growth for clinical applications. Copyright © 2017 John Wiley & Sons, Ltd.

  18. Type A aortic dissection associated with Dietzia maris.

    Science.gov (United States)

    Reyes, Guillermo; Navarro, José-Luis; Gamallo, Carlos; delas Cuevas, María-Carmen

    2006-10-01

    Aortitis is a rare cause of aortic dissection. We report the unusual presentation of a 77-year-old male patient who underwent emergency surgery for an aortic dissection type A. A purulent pericardial fluid and inflammatory aorta were found after chest opening. Several samples were sent for analysis. The ascending aorta presented a mild dilatation with a large haematoma infiltrating the aortic root. The distal part of the ascending aorta seemed unaffected. The aortic rupture was found one centimetre above the non-coronary cusp. Aortic wall tissues were extremely fragile and with an inflammatory aspect. The patient died in the theatre room. In the histological study one out of three fragments of ascending aorta displayed longitudinal splitting of the outer media, with blood extravasation in the adventitial layer. In this level, the presence of a detritus material that reminded of bacterial colonies was noteworthy, together with abundant fibrinous exudates. In the laboratory a new specimen, Dietzia maris, was found in the pericardial liquid and in the aortic wall. We believe that this is the first reported finding of Dietzia maris in a patient with aortic disease.

  19. A patient with ascending aortic dilatation, similar to phenotypes of connective tissue disorders.

    Science.gov (United States)

    Onrat, S T; Emmiler, M; Sivaci, Y; Söylemez, Z; Ozgöz, A; Imirzalioğlu, N

    2009-04-14

    We report on the clinical and molecular findings of a patient who presented alopecia, epicanthus, micrognathia, retrognathia, high arched palate, hypertelorism, Chiari type I malformation, mixed-type hearing loss but with normal heartbeat Q-T interval, malformed earlobes, down-slanted palpebral fissures, downturned corners of the mouth, syndactyly, atopic eczema, and seizures. The patient was a male adult, 23 years old, with short stature (153 cm) and low weight (50.5 kg), due to severe aortic insufficiency and dilatation of the ascending aorta. Conventional cytogenetic screening did not show any chromosomal gains or losses. Molecular genetic screening was conducted for gene mutations involved in various syndromes; the mutations found included [beta-fibrinogen -455 G>A wt/wt (wt/mut), PAI-1 4G/5G (4G/4G), HPA1 a/b (a/a), MTHFR C677T wt/wt (wt/mut), ACE I/D (I/I), and Apo E E3/E4]. Many clinical and molecular genetics findings overlapped with other conditions associated with arterial tortuosity and arterial aneurysms, including the Marfan, Ehler-Danlos, Shprintzen-Goldberg, and Loeys-Dietz syndromes. Although a diagnosis of Shprintzen-Goldberg syndrome was based on clinical findings and radiographic findings indicate other syndromes, aortic root dilatation seems to be a new symptom, similar to phenotypes of connective tissue disorders. The unique grouping of clinical manifestations in this patient and the molecular genetics findings lead us to suggest that this case could be an example of a previously unrecognized syndrome.

  20. Endovascular Treatment of a Carotid Dissecting Pseudoaneurysm in a Patient with Ehlers-Danlos Syndrome Type IV with Fatal Outcome

    International Nuclear Information System (INIS)

    Lim, Siok Ping; Duddy, Martin J.

    2008-01-01

    We present a patient with Ehlers-Danlos syndrome type IV (EDS IV) with a carotid dissecting pseudoaneurysm causing severe carotid stenosis. This lesion was treated endovascularly. Unfortunately, the patient died of remote vascular catastrophes (intracranial hemorrhage and abdominal aortic rupture). This unique case illustrates the perils of endovascular treatment of EDS IV patients and the need for preoperative screening for concomitant lesions. It also shows that a dissecting pseudoaneurysm can feasibly be treated with a covered stent and that closure is effective using Angioseal in patients with EDS IV

  1. Dilation of the ascending aorta in Turner syndrome - a prospective cardiovascular magnetic resonance study

    Directory of Open Access Journals (Sweden)

    Pedersen Erik M

    2011-04-01

    Full Text Available Abstract Background The risk of aortic dissection is 100-fold increased in Turner syndrome (TS. Unfortunately, risk stratification is inadequate due to a lack of insight into the natural course of the syndrome-associated aortopathy. Therefore, this study aimed to prospectively assess aortic dimensions in TS. Methods Eighty adult TS patients were examined twice with a mean follow-up of 2.4 ± 0.4 years, and 67 healthy age and gender-matched controls were examined once. Aortic dimensions were measured at nine predefined positions using 3D, non-contrast and free-breathing cardiovascular magnetic resonance. Transthoracic echocardiography and 24-hour ambulatory blood pressure were also performed. Results At baseline, aortic diameters (body surface area indexed were larger at all positions in TS. Aortic dilation was more prevalent at all positions excluding the distal transverse aortic arch. Aortic diameter increased in the aortic sinus, at the sinotubular junction and in the mid-ascending aorta with growth rates of 0.1 - 0.4 mm/year. Aortic diameters at all other positions were unchanged. The bicuspid aortic valve conferred higher aortic sinus growth rates (p Conclusion A general aortopathy is present in TS with enlargement of the ascending aorta, which is accelerated in the presence of a bicuspid aortic valve.

  2. Aortopathy in Congenital Heart Disease in Adults: Aortic Dilatation with Decreased Aortic Elasticity that Impacts Negatively on Left Ventricular Function.

    Science.gov (United States)

    Niwa, Koichiro

    2013-04-01

    Bicuspid aortic valve and/or coarctation of the aorta are consistently associated with ascending aortic and para-coarctation medial abnormalities. Medial abnormalities in the ascending aorta are prevalent in other types of patients with a variety of forms congenital heart disease (CHD), such as single ventricle, persistent truncus arteriosus, transposition of the great arteries, hypoplastic left heart syndrome, tetralogy of Fallot. These abnormalities encompass a wide age range, and may predispose to dilatation, aneurysm, and rupture that necessitates aortic valve and root surgery. This dilatation can develop in CHD patients without stenotic region. These CHDs exhibit ongoing dilatation of the aortic root and reduced aortic elasticity and increased aortic stiffness that may relate to intrinsic properties of the aortic root. The concept of aortic dilatation is shifting a paradigm of aortic dilatation, as so called post stenotic dilatation, to primary intrinsic aortopahy. These aortic dilatation and increased stiffness can induce aortic aneurysm, rupture of the aorta and aortic regurgitation, but also provoke left ventricular hypertrophy, reduced coronary artery flow and left ventricular failure. We can recognize this association of aortic pathophysiological abnormality, aortic dilation and aorto-left ventricular interaction as a new clinical entity: "aortopathy".

  3. Computational modeling of blood flow in the aorta--insights into eccentric dilatation of the ascending aorta after surgery for coarctation.

    Science.gov (United States)

    Szopos, Marcela; Poussineau, Nicole; Maday, Yvon; Canniffe, Carla; Celermajer, David S; Bonnet, Damien; Ou, Phalla

    2014-10-01

    To assess whether combining a computational modeling technique with data from patient magnetic resonance imaging studies can detect different fluid dynamics and vascular biomechanical properties of the ascending and horizontal aorta in patients with angulated "gothic" arch geometry compared with those with normal "Romanesque" arch geometry after aortic coarctation repair. Advanced computational fluid dynamics techniques (coupled Navier-Stokes and elastodynamics equations) were used to predict the fluid-wall interactions in large arteries. We modeled the fluid dynamics and shear stress in the ascending and horizontal aorta in cases of "gothic" arch and normal "Romanesque" aortic arch geometry. A total of 30 patients after aortic coarctation repair prospectively underwent 3-dimensional magnetic resonance imaging angiography of the thoracic aorta. Measurements of the ascending and horizontal aorta were assessed using multiplanar reformatting images. Our computational model demonstrated that wall shear stress is greater in those with an angulated "gothic" aortic arch than in those with a "Romanesque" arch. In particular, wall shear stress affected the anterior and posterior segments of the ascending aorta and the inferior and superior segments of the horizontal aorta (vs the left and right segments). In vivo, a "gothic" arch was associated with dilatation of the ascending and horizontal aorta, which was eccentric rather than concentric (Pgothic" aortic arch after repair of coarctation. This suggests that patients with an angulated "gothic" aortic arch might warrant increased surveillance for aortic complications. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  4. The bicuspid aortic valve and its relation to aortic dilation

    Directory of Open Access Journals (Sweden)

    Shi-Min Yuan

    2010-01-01

    Full Text Available BACKGROUND: A bicuspid aortic valve (BAV is a common congenital heart disease, which affects 1-2% of the population. However, the relationship between BAVs and aortic dilation has not been sufficiently elucidated. METHODS: A total of 241 BAV patients who were referred to this hospital for cardiac surgey over a 4.75-year period were included in this study. In addition to the clinical characteristics of the included patients, the morphological features of the aortic valve and aorta, the length of the left main coronary artery, and the laboratory findings (the coagulation and hematological parameters as well as the total cholesterol concentration were determined and compared with those of the tricuspid aortic valve (TAV patients. RESULTS: The BAV patients were younger than the TAV patients for a valve surgery in the last 3 months of the study period. The BAV patients were predominantly male. Most of the BAVs that were surgically treated were stenotic, regurgitant, or combined, and only 19 (7.88% were normally functioning valves. According to echocardiography or operative records, 148 (78.31% were type A, 31 (16.40% were type B, and 10 (5.29% were type C. The left main coronary artery was much shorter in the BAV patients than it was in the TAV patients. There was no significant difference between BAV and TAV patients in the total cholesterol concentrations; whereas differences were noted between patients receiving lipid-lowering therapy and those not receiving lipid-lowering therapy. The dimensions of the aortic root, sinotubular junction, and ascending aorta were beyond normal limits, while they were significantly smaller in the BAV patients than in the TAV patients. They were also much smaller in patients receiving statin therapy than those not receiving statin therapy in both groups. Moreover, the aortic dilation in the BAV group was found to be significantly associated with patient age. CONCLUSIONS: The BAV patients developed aortic wall and

  5. Reinforced aortic root reconstruction for acute type A aortic dissection involving the aortic root

    Directory of Open Access Journals (Sweden)

    Han Qing-qi

    2013-06-01

    Full Text Available OBJECTIVE: There are debates regarding the optimal approach for AAAD involving the aortic root. We described a modified reinforced aortic root reconstruction approach for treating AAAD involving the aortic root. METHODS: A total of 161 patients with AAAD involving the aortic root were treated by our modified reinforced aortic root reconstruction approach from January 1998 to December 2008. Key features of our modified approach were placement of an autologous pericardial patch in the false lumen, lining of the sinotubular junction lumen with a polyester vascular ring, and wrapping of the vessel with Teflon strips. Outcome measures included post-operative mortality, survival, complications, and level of aortic regurgitation. RESULTS: A total of 161 patients were included in the study (mean age: 43.3 1 15.5 years. The mean duration of follow-up was 5.1 1 2.96 years (2-12 years. A total of 10 (6.2% and 11 (6.8% patients died during hospitalization and during follow-up, respectively. Thirty-one (19.3% patients experienced postoperative complications. The 1-, 3-, 5-, and 10-year survival rates were 99.3%, 98%, 93.8%, and 75.5%, respectively. There were no instances of recurrent aortic dissection, aortic aneurysm, or pseudoaneurysm during the entire study period. The severity of aortic regurgitation dramatically decreased immediately after surgery (from 28.6% to 0% grade 3-4 and thereafter slightly increased (from 0% to 7.2% at 5 years and 9.1% at 10 years. CONCLUSION: This modified reinforced aortic root reconstruction was feasible, safe and durable/effective, as indicated by its low mortality, low postoperative complications and high survival rate.

  6. Reoperative Aortic Root Replacement in Patients with Previous Aortic Root or Aortic Valve Procedures

    Directory of Open Access Journals (Sweden)

    Byung Kwon Chong

    2016-08-01

    Full Text Available Background: Generalization of standardized surgical techniques to treat aortic valve (AV and aortic root diseases has benefited large numbers of patients. As a consequence of the proliferation of patients receiving aortic root surgeries, surgeons are more frequently challenged by reoperative aortic root procedures. The aim of this study was to evaluate the outcomes of redo-aortic root replacement (ARR. Methods: We retrospectively reviewed 66 patients (36 male; mean age, 44.5±9.5 years who underwent redo-ARR following AV or aortic root procedures between April 1995 and June 2015. Results: Emergency surgeries comprised 43.9% (n=29. Indications for the redo-ARR were aneurysm (n=12, pseudoaneurysm (n=1, or dissection (n=6 of the residual native aortic sinus in 19 patients (28.8%, native AV dysfunction in 8 patients (12.1%, structural dysfunction of an implanted bioprosthetic AV in 19 patients (28.8%, and infection of previously replaced AV or proximal aortic grafts in 30 patients (45.5%. There were 3 early deaths (4.5%. During follow- up (median, 54.65 months; quartile 1–3, 17.93 to 95.71 months, there were 14 late deaths (21.2%, and 9 valve-related complications including reoperation of the aortic root in 1 patient, infective endocarditis in 3 patients, and hemorrhagic events in 5 patients. Overall survival and event-free survival rates at 5 years were 81.5%±5.1% and 76.4%±5.4%, respectively. Conclusion: Despite technical challenges and a high rate of emergency conditions in patients requiring redo-ARR, early and late outcomes were acceptable in these patients.

  7. Aortic root reconstruction by aortic valve-sparing operation (David type I reimplantation) in Marfan syndrome accompanied by annuloaortic ectasia and acute type-A aortic dissection.

    Science.gov (United States)

    Inamura, Shunichi; Furuya, Hidekazu; Yagi, Kentarou; Ikeya, Eriko; Yamaguchi, Masaomi; Fujimura, Takabumi; Kanabuchi, Kazuo

    2006-09-20

    To reconstruct the aortic root for aneurysm of the ascending aorta accompanied by aortic regurgitation, annuloaortic ectasia (AAE) and acute type-A dissection with root destruction, the Bentall operation using a prosthetic valve still is the standard procedure today. Valve-sparing procedures have actively been used for aortic root lesions, and have also been attempted in aortic root reconstruction for Marfan syndrome which may have abnormalities in the valve leaflets. We conducted a valve-sparing procedure in a female patient with Marfan syndrome who had AAE accompanied by type-A acute aortic dissection. The patient was a 37-year-old woman complaining of severe pain from the chest to the back. The limbs were long, and funnel breast was observed. Diastolic murmurs were heard. On chest computed tomography, a dissection cavity was present from the ascending aorta to the left common iliac artery, and the root dilated to 55 mm. Grade II aortic regurgitation was observed on ultrasound cardiography. Regarding her family history, her father had died suddenly at 54 years of age. She was diagnosed with type-A acute dissection concurrent with Marfan syndrome and AAE. The structure of the aortic valve was normal, and root reconstruction by a valve-sparing operation and total replacement of the aortic arch was conducted. On postoperative ultrasound cardiography, the aortic regurgitation was within the allowable range, and the shortterm postoperative results were good.

  8. Lumbar Artery Pseudoaneurysm: A Complication of Percutaneous Nephrostomy

    Directory of Open Access Journals (Sweden)

    Melody Djuimo

    2017-07-01

    Full Text Available A 21 year-old male underwent nephrostomy tube insertion for hydronephrosis due to a large para-aortic adenopathy of a testicular tumor. In order to reduce infections during chemotherapy, a ureteral stent was placed. While removing the nephrostomy tube, a pulsatile bleeding was found and a renal angiography was done. A pseudoaneurysm of his first left lumbar (L1 artery communicating with the nephrostomy's access site was found. An embolization was performed with coils in the left L1 artery and one of its subdivisions. Post-embolization controls revealed no bleeding. On the follow-up CT, there were no suspicious retroperitoneal mass.

  9. A case of complete double aortic arch visualized by transthoracic echocardiography.

    Science.gov (United States)

    Saito, Naka; Kato, Shingo; Saito, Noritaka; Nakachi, Tatsuya; Fukui, Kazuki; Iwasawa, Tae; Kosuge, Masami; Kimura, Kazuo

    2017-08-01

    A case of double aortic arch that was well visualized using transthoracic echocardiography is reported. A 38-year-old man underwent transthoracic echocardiography for the evaluation of dyspnea. A suprasternal view of transthoracic echocardiography showed the ascending aorta bifurcate to left and right aortic arches, with blood flow from the ascending aorta to bilateral aortic arches. The diagnosis of right side-dominant double aortic arch was made, and the patient's symptom was conceivably related to compression of the trachea due to a vascular ring. This report indicates the potential usefulness of transthoracic echocardiography for noninvasive detection of double aortic arch in adults. © 2017, Wiley Periodicals, Inc.

  10. A Gly1127Ser mutation in an EGF-like domain of the Fibrillin-I gene is a risk factor for ascending aortic aneurysm and dissection

    Energy Technology Data Exchange (ETDEWEB)

    Francke, U.; Berg, M.A.; Tynan, K. [Stanford Univ. Medical Center, CA (United States)] [and others

    1995-06-01

    Ascending aortic disease, ranging from mild aortic root enlargement to aneurysm and/or dissection, has been identified in 10 individuals of a kindred, none of whom had classical Marfan syndrome (MFS). Single-strand conformation analysis of the entire fibrillin-1 (FBN1) cDNA of an affected family member revealed a G-to-A transition at nucleotide 3379, predicting a Gly1127Ser substitution. The glycine in this position is highly conserved in EGF-like domains of FBN1 and other proteins. This mutation was present in 9 of 10 affected family members and in 1 young unaffected member but was not found in other unaffected members, in 168 chromsomes from normal controls, and in 188 chromosomes from other individuals with MFS or related phenotypes. FBN1 intragenic marker haplotypes ruled out the possibility that the other allele played a significant role in modulating the phenotype in this family. Pulse-chase studies revealed normal fibrillin synthesis but reduced fibrillin deposition into the extracellular matrix in cultured fibroblasts from a Gly1127Ser carrier. We postulate that the Gly1127Ser FBN1 mutation is responsible for reduced matrix deposition. We suggest that mutations such as this one may disrupt EFG-like domain folding less drastically than do substitutions of cysteine or of other amino acids important for calcium-binding that cause classical MFS. The Gly 1127Ser mutation, therefore, produces a mild form of autosomal dominantly inherited weakness of elastic tissue, which predisposes to ascending aortic aneurysm and dissection later in life. 33 refs., 6 figs.

  11. Segmental Aortic Stiffness in Children and Young Adults With Connective Tissue Disorders: Relationships With Age, Aortic Size, Rate of Dilation, and Surgical Root Replacement.

    Science.gov (United States)

    Prakash, Ashwin; Adlakha, Himanshu; Rabideau, Nicole; Hass, Cara J; Morris, Shaine A; Geva, Tal; Gauvreau, Kimberlee; Singh, Michael N; Lacro, Ronald V

    2015-08-18

    Aortic diameter is an imperfect predictor of aortic complications in connective tissue disorders (CTDs). Novel indicators of vascular phenotype severity such as aortic stiffness and vertebral tortuosity index have been proposed. We assessed the relation between aortic stiffness by cardiac MRI, surgical root replacement, and rates of aortic root dilation in children and young adults with CTDs. Retrospective analysis of cardiac MRI data on children and young adults with a CTD was performed to derive aortic stiffness measures (strain, distensibility, and β-stiffness index) at the aortic root, ascending aorta, and descending aorta. Vertebral tortuosity index was calculated as previously described. Rate of aortic root dilation before cardiac MRI was calculated as change in echocardiographic aortic root diameter z score per year. In 83 CTD patients (median age, 24 years; range, 1-55; 17% age; 60% male), ascending aorta distensibility was reduced in comparison with published normative values: median z score, -1.93 (range, -8.7 to 1.3; Pyoung adults with CTDs. © 2015 American Heart Association, Inc.

  12. Aortic compliance in patients with aortic regurgitation. Evaluation with magnetic resonance imaging

    International Nuclear Information System (INIS)

    Murai, Sachiko; Hamada, Seiki; Ueguchi, Takashi

    2005-01-01

    The purpose of this study was to assess by means of cine magnetic resonance imaging (MRI) aortic compliance before and after aortic valve replacement (AVR with SJM (St. Jude Medical, St paul, MN) valve) in patients with aortic regurgitation (AR). Two groups (healthy controls and patients with severe isolated AR) of 10 subjects each were included in this study. Cine MRI was performed at three locations of the aorta, and aortic compliance was calculated by dividing the maximum change in the aortic area by pulse pressure. Cine MRI is useful to assess abnormalities of aortic compliance in patients with AR. Compared with the control group, aortic compliance in the AR group was significantly less in the ascending aorta (p<0.05), decreasing in order of aortic location. After AVR, aortic compliance improved for all locations. Cine MRI enables assessment of aortic biophysical properties such as a compliance for evaluating the progression of AR and the efficacy of treatment. (author)

  13. Emergency endovascular management of peripheral artery aneurysms and pseudoaneurysms – a review

    Directory of Open Access Journals (Sweden)

    Gillard Jonathan H

    2008-07-01

    Full Text Available Abstract Endovascular stenting has been successfully employed in the management of aortic aneurysms; however, its use in managing peripheral arterial conditions remains questionable. We review the utility of endovascular technique in the management of peripheral arterial conditions like aneurysms, pseudoaneurysms and arterio-venous fistulas in the emergency setting. Though long term data about graft patency rates is not yet available, the endovascular approach appears to be a useful minimally invasive technique in situations where open repair is either difficult or not feasible.

  14. The problem of calcified ascending aorta during aortocoronary bypass

    Directory of Open Access Journals (Sweden)

    Nežić Duško G.

    2004-01-01

    Full Text Available Heavily calcified ascending aorta significantly increased morbidity and lethality during open-heart surgery. Cannulation and clamping (partial or total of severely atherosclerotic ascending aorta can easily cause damage and rupture of aortic wall, with consequential distal (often fatal embolization with atheromatous debris (brain, myocardium. From June 1998. until June 2000, 11 of 2 136 (0.5% patients who underwent coronary artery bypass grafting were with the severe atheromatous ascending aorta. The site of cannulation was in the aortic arch in three patients (aorta was occluded with Foley catheter in one case, and single clamp technique was used in the other two cases. The femoral artery was the cannulation site in other five cases. Profound hypothermia, ventricular fibrillation, and circulatory arrest, with no cross-clamping or cardioplegia, were used in three patients. Two patients were operated on with extracorporeal circulation, one in normothermia, on the beating heart, the other in moderate hypothermia, on fibrillating heart. In three patients myocardial revascularization was performed on the beating heart, in normothermia, without extracorporeal circulation. Postoperative course was uneventful in all 11 patients. Neither atheroembolism in the peripheral organs, nor atheroembolism of the extramities occurred. The proposed surgical approaches have the potential to reduce the prevalence of stroke and systemic embolization associated with coronary artery bypass grafting in patients with heavily calcified ascending aorta. This result was achieved due to the applied modifications of standard cardiosurgical technique.

  15. Evaluation of Aortic Blood Flow and Wall Shear Stress in Aortic Stenosis and Its Association With Left Ventricular Remodeling

    Science.gov (United States)

    von Knobelsdorff-Brenkenhoff, Florian; Karunaharamoorthy, Achudhan; Trauzeddel, Ralf Felix; Barker, Alex J; Blaszczyk, Edyta; Markl, Michael; Schulz-Menger, Jeanette

    2016-01-01

    Background Aortic stenosis (AS) leads to variable stress for the left ventricle (LV) and consequently a broad range of LV remodeling. Study aim was to describe blood flow patterns in the ascending aorta of AS patients and determine their association with remodeling. Methods and Results Thirty-seven patients with AS (14 mild, 8 moderate, 15 severe; age 63±13 years) and 37 healthy controls (age 60±10 years) underwent 4D-flow MRI. Helical and vortical flow formations and flow eccentricity were assessed in the ascending aorta. Normalized flow displacement from the vessel center and peak systolic wall shear stress (WSSpeak) in the ascending aorta were quantified. LV remodeling was assessed based on LV mass index (LVMI-I) and the ratio of LV mass to enddiastolic volume (relative wall mass; RWM). Marked helical and vortical flow formation and eccentricity were more prevalent in patients with AS than in healthy subjects, and AS patients exhibited an asymmetric and elevated distribution of WSSpeak. In AS, aortic orifice area was strongly negatively associated with vortical flow formation (p=0.0274), eccentricity (p=0.0070) and flow displacement (p=0.0021). Bicuspid aortic valve was associated with more intense helical (p=0.0098) and vortical flow formation (p=0.0536), higher flow displacement (p=0.11) and higher WSSpeak (p=0.0926). LVM-I and RWM were significantly associated with aortic orifice area (p=0.0611, p=0.0058) and flow displacement (p=0.0058, p=0.0283). Conclusions In this pilot study, AS leads to abnormal blood flow pattern and WSSpeak in the ascending aorta. In addition to aortic orifice area, normalized flow displacement was significantly associated with LV remodeling. PMID:26917824

  16. Aortic Volumetry at Contrast-Enhanced Magnetic Resonance Angiography: Feasibility as a Sensitive Method for Monitoring Bicuspid Aortic Valve Aortopathy.

    Science.gov (United States)

    Trinh, Brian; Dubin, Iram; Rahman, Ozair; Ferreira Botelho, Marcos P; Naro, Nicholas; Carr, James C; Collins, Jeremy D; Barker, Alex J

    2017-04-01

    Bicuspid aortic valve patients can develop thoracic aortic aneurysms and therefore require serial imaging to monitor aortic growth. This study investigates the reliability of contrast-enhanced magnetic resonance angiography (CEMRA) volumetry compared with 2-dimensional diameter measurements to identify thoracic aortic aneurysm growth. A retrospective, institutional review board-approved, and Health Insurance Portability and Accountability Act-compliant study was conducted on 20 bicuspid aortic valve patients (45 ± 8.9 years, 20% women) who underwent serial CEMRA with a minimum imaging follow-up of 11 months. Magnetic resonance imaging was performed at 1.5 T with electrocardiogram-gated, time-resolved CEMRA. Independent observers measured the diameter at the sinuses of Valsalva (SOVs) and mid ascending aorta (MAA) as well as ascending aorta volume between the aortic valve annulus and innominate branch. Intraobserver/interobserver coefficient of variation (COV) and intraclass correlation coefficient (ICC) were computed to assess reliability. Growth rates were calculated and assessed by Student t test (P volumetry. Three-dimensional CEMRA volumetry exhibited a larger effect when examining percentage growth, a better ICC, and a marginally lower COV. Volumetry may be more sensitive to growth and possibly less affected by error than diameter measurements.

  17. Valva aórtica bicúspide: fundamentos teóricos e clínicos para substituição simultânea da aorta ascendente Bicuspid aortic valve: theoretical and clinical aspects of concomitant ascending aorta replacement

    Directory of Open Access Journals (Sweden)

    Mauro Paes Leme De Sá

    2009-06-01

    Full Text Available A valva aórtica bicúspide (VAB está associada à ectasia ânulo-aórtica, aneurisma e dissecção da aorta ascendente. A alta incidência desta malformação congênita e doença da aorta sugere íntima relação entre os fenômenos. Anormalidades ocorrendo em diferentes fases da migração das células da crista neural podem ser responsáveis pela ocorrência em anormalidades na valva aórtica, na camada média da aorta ascendente e nos vasos do arco aórtico. Estudos prévios revelam que mesmo indivíduos com VAB normal ou com disfunção leve podem apresentar dilatação da raiz aórtica. Os autores acreditam que somente as alterações hemodinâmicas produzidas por uma VAB sem estenose ou insuficiência parecem ser insuficientes para as graves complicações vasculares observadas nos portadores de VAB. Vários mecanismos têm sido propostos para explicar os achados moleculares e histológicos desta doença. Encontramos a redução da fibrilina-1 na aorta ascendente e artéria pulmonar como possível causa. Histologicamente, a aorta ascendente pode apresentar necrose cística da média e fragmentação elástica, semelhante àquela encontrada em portadores de síndrome de Marfan. Vários autores atualmente recomendam que em se operando um paciente com VAB, especialmente aqueles com insuficiência aórtica, mesmo na presença de uma discreta dilatação (45 mm deve-se substituir a valva aórtica e a aorta ascendente concomitantemente quando a expectativa de vida exceder 10 anos, para se prevenir futuros aneurismas ou rupturas.Bicuspid aortic valve (BAV is associated with annuloaortic ectasia, dissection and ascending aortic aneurysm. The high incidence of this congenital malformation and aortic disease suggests a close correlation between the two phenomena. Abnormalities in different phases of cell migration of the neural crest might be responsible for the occurrence of abnormalities in the aortic valve, media layer of the ascending aorta

  18. Acute myocardial ischemia after aortic valve replacement: A comprehensive diagnostic evaluation using dynamic multislice spiral computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lembcke, Alexander [Department of Radiology, Charite-Universitaetsmedizin Berlin, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Berlin (Germany)]. E-mail: alexander.lembcke@gmx.de; Hein, Patrick A. [Department of Radiology, Charite-Universitaetsmedizin Berlin, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Berlin (Germany); Enzweiler, Christian N.H. [Department of Radiology, Charite-Universitaetsmedizin Berlin, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Berlin (Germany); Hoffmann, Udo [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Klessen, Christian [Department of Radiology, Charite-Universitaetsmedizin Berlin, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Berlin (Germany); Dohmen, Pascal M. [Department of Cardiovascular Surgery, Charite-Universitaetsmedizin Berlin, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Berlin (Germany)

    2006-03-15

    We describe the case of a 72-year-old man presenting with endocarditis and clinical signs of acute myocardial ischemia after biological aortic valve replacement. A comprehensive cardiac dynamic multislice spiral computed tomography demonstrated: (1) an endocarditic vegetation of the aortic valve; (2) a subvalvular leakage feeding a paravalvular pseudoaneurysm based on an aortic root abscess with subsequent compromise of the systolic blood flow in the left main coronary artery and the resulting myocardial perfusion deficit.

  19. Acute myocardial ischemia after aortic valve replacement: A comprehensive diagnostic evaluation using dynamic multislice spiral computed tomography

    International Nuclear Information System (INIS)

    Lembcke, Alexander; Hein, Patrick A.; Enzweiler, Christian N.H.; Hoffmann, Udo; Klessen, Christian; Dohmen, Pascal M.

    2006-01-01

    We describe the case of a 72-year-old man presenting with endocarditis and clinical signs of acute myocardial ischemia after biological aortic valve replacement. A comprehensive cardiac dynamic multislice spiral computed tomography demonstrated: (1) an endocarditic vegetation of the aortic valve; (2) a subvalvular leakage feeding a paravalvular pseudoaneurysm based on an aortic root abscess with subsequent compromise of the systolic blood flow in the left main coronary artery and the resulting myocardial perfusion deficit

  20. Aorto-right atrial fistula after Bentall repair

    OpenAIRE

    Howard, Charles E.; Velasco, Carlos E.; Roullard, Christina P.; Rafael, Aldo

    2017-01-01

    We describe a man with the Marfan syndrome and a prior ascending aortic aneurysm resection who presented with knee pain and concern of endocarditis. Transesophageal echocardiogram showed no vegetations, and computed tomography angiogram of the heart showed a possible pseudoaneurysm. Cardiac catheterization and aortogram revealed the diagnosis of an aorto-right atrial fistula, which was then operatively repaired. This case highlights the role that cardiac catheterization with aortogram can pla...

  1. Massive aggrecan and versican accumulation in thoracic aortic aneurysm and dissection.

    Science.gov (United States)

    Cikach, Frank S; Koch, Christopher D; Mead, Timothy J; Galatioto, Josephine; Willard, Belinda B; Emerton, Kelly B; Eagleton, Matthew J; Blackstone, Eugene H; Ramirez, Francesco; Roselli, Eric E; Apte, Suneel S

    2018-03-08

    Proteoglycan accumulation is a hallmark of medial degeneration in thoracic aortic aneurysm and dissection (TAAD). Here, we defined the aortic proteoglycanome using mass spectrometry, and based on the findings, investigated the large aggregating proteoglycans aggrecan and versican in human ascending TAAD and a mouse model of severe Marfan syndrome. The aortic proteoglycanome comprises 20 proteoglycans including aggrecan and versican. Antibodies against these proteoglycans intensely stained medial degeneration lesions in TAAD, contrasting with modest intralamellar staining in controls. Aggrecan, but not versican, was increased in longitudinal analysis of Fbn1mgR/mgR aortas. TAAD and Fbn1mgR/mgR aortas had increased aggrecan and versican mRNAs, and reduced expression of a key proteoglycanase gene, ADAMTS5, was seen in TAAD. Fbn1mgR/mgR mice with ascending aortic dissection and/or rupture had dramatically increased aggrecan staining compared with mice without these complications. Thus, aggrecan and versican accumulation in ascending TAAD occurs via increased synthesis and/or reduced proteolytic turnover, and correlates with aortic dissection/rupture in Fbn1mgR/mgR mice. Tissue swelling imposed by aggrecan and versican is proposed to be profoundly deleterious to aortic wall mechanics and smooth muscle cell homeostasis, predisposing to type-A dissections. These proteoglycans provide potential biomarkers for refined risk stratification and timing of elective aortic aneurysm repair.

  2. [Surgical results for aortic involvement in Marfan syndrome].

    Science.gov (United States)

    Shiiya, N; Matsuzaki, K; Maruyama, R; Kunihara, T; Murashita, T; Aoki, H; Yasuda, K

    2002-07-01

    From 1991 through 2001, 21 Marfan patients underwent aortic operations in our hospital. They received a total of 36 aortic operations, 31 by ourselves including 4 non-elective operations and 2 operations before 1991. Extent of replacement was Bentall + total arch (4), Bentall (8), valve sparing aortic root (reimplantation) (2), re-anastomosis + coronary aortic bypass grafting (CABG) after Bentall (1), ascending + total arch (3), ascending (1), total arch (1), total thoracoabdominal (10), thoracoabdominal (1), descending thoracic (2), distal arch (1), abdominal (2). Multiple operations were required in 11 patients (2 operations in 7, 3 operations in 4). Eight reoperations in 6 patients were for adjacent lesion, 5 reoperations were for remote lesion, and 2 others were for complication of Bentall (initial operation elsewhere). Among the 8 reoperations for adjacent lesion, 3 were scheduled operation (2 with elephant trunk), 4 were for residual dissection, and 1 was for annulo-aortic ectasia (AAE). Total aortic replacement was achieved in 4 and subtotal replacement excluding the root in 2. There was no hospital mortality. Paraparesis occurred in 1 who died 4.7 years after operation. The remaining patients are currently alive. No other aortic event occurred. Aortic reoperation-free survival was 83% at 5 year and 28% at 10 year.

  3. Dilatation and Dysfunction of the Neo-aortic Root and in 76 Patients After the Ross Procedure.

    Science.gov (United States)

    Zimmermann, Corina A; Weber, Roland; Greutmann, Matthias; Dave, Hitendu; Müller, Christoph; Prêtre, René; Seifert, Burkhardt; Buechel, Emanuela Valsangiacomo; Kretschmar, Oliver; Attenhofer Jost, Christine H

    2016-08-01

    Pulmonary autograft replacement (Ross procedure) is used as an alternative to prosthetic aortic valve replacement patients with aortic valve disease. There are limited data on incidence and risk factors for dilatation and dysfunction of the neo-aortic after the Ross procedure. Ross procedure was performed in 100 patients at our institution between 1993 and 2011. In 76 patients, complete follow-up data were available. Their median age at surgery was 16 (0.4-58) years (76 % males; 95 % with congenital aortic valve disease). Median follow-up duration was 5.2 years (0.3-16.0 years). We analyzed their clinical and echocardiographic follow-up to identify possible risk factors for neo-aortic root dilatation and dysfunction. Ross procedure included reduction plasty of the native ascending aorta in 25 % of patients. During follow-up, 21 patients (28 %) developed neo-aortic root dilatation, 38 patients (50 %) dilatation oft the native ascending aorta and 7 patients (9 %) at least moderate neo-aortic regurgitation. Univariate risk factors for neo-aortic root dilatation were preoperative aortic regurgitation (p = 0.04), concomitant reduction plasty of the ascending aorta (p = 0.009) and a longer duration of follow-up (p = 0.005). Younger age at surgery was associated with dilatation of the ascending aorta (p = 0.03). Reoperation on the neo-aortic root because of severe dilatation was necessary in 6 patients (8 %), where 2 patients had at least moderate neo-aortic root regurgitation. Neo-aortic root and aortic dilatation are common after the Ross procedure. This is often combined with neo-aortic valve dysfunction. Close follow-up of these patients is mandatory.

  4. [Vacuum-assisted Closure (VAC) Treatment for Sternal Infection in a Patient after Cardiovascular Surgery; Report of a Case].

    Science.gov (United States)

    Shima, Shotaro; Okamura, Kennichi; Morizumi, Sei; Kanamori, Taro; Ichihara, Tetsuya; Kawata, Mitsuhiro; Suematsu, Yoshihiro

    2015-03-01

    One year ago, a 42-year-old woman underwent aortic root replacement because of a pseudoaneurysm that developed at the site of an anastomosis after ascending aortic replacement for acute aortic dissection. Six months later, she complained of fever and cough. A computed tomography revealed recurrence of the peudoaneurysm at the proximal anastomosis of the aortic root replacement. After emergency re-do aortic root replacement, she was admitted to intensive care unit (ICU) without sternal closure because of mediastinitis. The mediastinitis was managed by debridement and lavage drainage, followed by vacuum-assisted closure (VAC) treatment. The VAC treatment facilitated wound healing and active rehabilitation using a portable device. Finally, the wound was closed completely using a skin graft. VAC treatment is considered very useful in a case of post-sternotomy madiastinitis.

  5. Radiotherapy-induced aortic valve disease associated with porcelain aorta

    International Nuclear Information System (INIS)

    Daitoku, Kazuyuki; Fukui, Kozo; Ichinoseki, Ikkoh; Munakata, Mamoru; Takahashi, Shoichi; Fukuda Ikuo

    2004-01-01

    Mediastinal irradiation has been reported to induce cardiac disease such as pericarditis, valvular dysfunction, conduction abnormalities, accelerated arteriosclerosis of the coronary arteries, and also calcifications of the ascending aorta. We herein describe a case of radiotherapy-induced porcelain aorta and aortic valve disease and their surgical treatment. The patient was diagnosed with myasthenia gravis (MG) in 1965 (Osserman's type II), and mediastinal irradiation was performed in 1970 for treatment of thymic tumor associated with MG. Thirty years after radiation therapy, complete atrioventricular block and aortic valve disease with severe calcification of the ascending aorta and aortic arch (porcelain aorta) were detected on echo cardiogram and cardiac catheterization. A permanent pacemaker was implanted via the left subclavian vein and aortic valve replacement was performed under extracorporeal circulation established by selective cerebral perfusion and balloon occlusion instead of aortic cross-clamping. As no risk factors of arteriosclerosis such as hypercholesterolemia, hyperglycemia and hypertension were apparent, we concluded that the aortic valve disease and porcelain aorta were primarily induced by radiotherapy. (author)

  6. Ascending aorta dilatation rates in patients with tricuspid and bicuspid aortic stenosis: the COFRASA/GENERAC study.

    Science.gov (United States)

    Kerneis, Caroline; Pasi, Nicoletta; Arangalage, Dimitri; Nguyen, Virginia; Mathieu, Tiffany; Verdonk, Constance; Codogno, Isabelle; Ou, Phalla; Duval, Xavier; Tubiana, Sarah; Cimadevilla, Claire; Vahanian, Alec; Messika-Zeitoun, And David

    2017-07-25

    Ascending aorta (AA) dilatation is common in aortic valve stenosis (AS) but data regarding AA progression, its determinants and impact of valve anatomy [bicuspid (BAV), or tricuspid (TAV)] are scarce. Asymptomatic AS patients enrolled in a prospective cohort (COFRASA/GENERAC) with at least 2 years of follow-up were considered in the present analysis. A transthoracic echocardiography (TTE) and a computed tomography (CT) scan were performed at inclusion and yearly thereafter. We enrolled 195 patients [mean gradient 22 ± 11 mmHg, 42 BAV patients (22%)]. Mean aorta diameters assessed using TTE were 35 ± 4 and 36 ± 5 mm at the sinuses of Valsalva and tubular level, respectively. Ascending aorta diameter was >40 mm in 29% of patients (24% in TAV vs. 52% in BAV, P  0.05). Only four patients presented an AA progression ≥2 mm/year. Correlations between TTE and CT scan were excellent (all r >0.74) and similar results were obtained using CT. During follow-up, two BAV patients underwent a combined AA surgery; no surgery was primarily performed for AA aneurysm and no dissection was observed. In this prospective cohort of AS patients determinants of AA diameters were age, sex, BSA, and valve anatomy but not AS severity. AA progression rates were low and not influenced by AS severity or valve anatomy. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  7. Geometric Deformations of the Thoracic Aorta and Supra-Aortic Arch Branch Vessels Following Thoracic Endovascular Aortic Repair.

    Science.gov (United States)

    Ullery, Brant W; Suh, Ga-Young; Hirotsu, Kelsey; Zhu, David; Lee, Jason T; Dake, Michael D; Fleischmann, Dominik; Cheng, Christopher P

    2018-04-01

    To utilize 3-D modeling techniques to better characterize geometric deformations of the supra-aortic arch branch vessels and descending thoracic aorta after thoracic endovascular aortic repair. Eighteen patients underwent endovascular repair of either type B aortic dissection (n = 10) or thoracic aortic aneurysm (n = 8). Computed tomography angiography was obtained pre- and postprocedure, and 3-D geometric models of the aorta and supra-aortic branch vessels were constructed. Branch angle of the supra-aortic branch vessels and curvature metrics of the ascending aorta, aortic arch, and stented thoracic aortic lumen were calculated both at pre- and postintervention. The left common carotid artery branch angle was lower than the left subclavian artery angles preintervention ( P Supra-aortic branch vessel angulation remains relatively static when proximal landing zones are distal to the left common carotid artery.

  8. Arterial homograft and medical therapy in pseudoaneurysm of infrarenal aorta concomitant with recurrent right ventricular thrombus in Behcet's disease

    International Nuclear Information System (INIS)

    Vahedian, Jalal; Sadeghapour, Ali

    2006-01-01

    Pseudoaneurysm of the infrarenal aorta due to Behcet s disease is very rare. We report a case of pseudoaneurysm associated with Behcet s disease in a 17-year-old boy with a recurrent right ventricular thrombus successfully treated with revascularization using arterial homograft patch. Echocardiography examination revealed a right ventricular mass, thought to be a thrombus in an unusual location. Postoperatively, the findings of the pathologic examination confirmed the mass as a thrombus. When the patient was subsequently re-admitted to the emergency unit with complaints of severe abdominal pain, fever, fatigue, sinus tachycardia, and a pulsating and tender abdominal mass, a right ventricular thrombus and a large pseudoaneurysm of the abdominal aorta were found on echocardiography and angiography. The patient underwent resection of the aortic aneurysm and aortoplasty, using arterial homograft patch, and received immunosuppressive and anticoagulation therapy. The thrombus of the right ventricle disappeared 4 months later. This case indicates that a right ventricular thrombosis in Behcet s disease may be managed by medical therapy. (author)

  9. Abnormalities of aortic arch shape, central aortic flow dynamics, and distensibility predispose to hypertension after successful repair of aortic coarctation.

    Science.gov (United States)

    Donazzan, Luca; Crepaz, Robert; Stuefer, Josef; Stellin, Giovanni

    2014-10-01

    Systemic hypertension (HT) is a major long-term complication even after successful repair of aortic coarctation (CoA), and many factors are involved in this pathophysiology. To investigate the role of abnormalities in the aortic arch shape, central aortic flow dynamics, and distensibility in developing HT after successful repair of CoA. We selected a group of 26 normotensive patients (mean age 16.9±7.3 years, range 9-32 years) with anatomically successful repair of CoA among 140 patients regularly followed after repair of CoA and analyzed their last clinical and echocardiographic data. Bicycle exercise test and ambulatory blood pressure monitoring (ABPM) were also obtained. Mean age at surgical repair was 3.2±3.9 years (range 10 days-15 years); 12 patients underwent surgical correction during the first year of life. Repair of CoA was performed by end-to-end anastomosis (TT) in 23 patients (extended TT in 6 patients with arch hypoplasia), patch aortoplasty in 2, and subcalvian flap aortoplasty in 1. The postsurgical follow-up was 13.8±7.2 years (range 3.5-29.4 years). The shape of the aortic arch was defined by magnetic resonance imaging (MRI) on this global geometry (normal-gothic-crenel), ratio of the height-transverse diameter (A/T), percentage of residual stenosis, and growth index of the transverse arch segments. Flow mapping by phase-contrast imaging in the ascending and descending aorta was performed in order to measure the systolic waveforms and central aortic distensibility. Twenty normal age-matched patients submitted to the same MRI protocol were used as controls. Six patients were found to have a gothic and 20 a normal aortic arch shape. Patients with gothic aortic arch shape had an increased A/T ratio (0.80±0.07 vs 0.58±0.05, P135 mm Hg on ABPM were higher in the gothic than in the normal arch group. There was a correlation between nocturnal SBP, 24 hours pulse pressure on ABPM in the whole group, and different MRI variables (A/T, distensibility of

  10. Repair of left coronary artery aneurysm, recurrent ascending aortic aneurysm, and mitral valve prolapse 19 years after Bentall's procedure in a patient with Marfan syndrome.

    Science.gov (United States)

    Badmanaban, Balaji; Mallon, Peter; Campbell, Norman; Sarsam, Mazin A I

    2004-01-01

    A 45-year-old female with Marfan syndrome had a Bentall's procedure performed 19 years ago. She presented with a 4-year history of gradually worsening dyspnea and decreasing exercise tolerance. Investigations revealed severe mitral valve prolapse, a left main stem coronary artery (LMSCA) aneurysm, and a recurrent aneurysm of the ascending aorta. The mitral valve was replaced and the aortic aneurysmal sac and the LMSCA aneurysm were then repaired by a modified Bentall procedure. The patient made an uneventful recovery and was discharged home.

  11. Thoracic type Ia endoleak: direct percutaneous coil embolization of the aortic arch at the blood entry site after TEVAR and double-chimney stent-grafts

    Energy Technology Data Exchange (ETDEWEB)

    Bangard, Christopher; Franke, Mareike; Maintz, David; Chang, De-Hua [University Hospital, University of Cologne, Department of Radiology, Cologne (Germany); Pfister, Roman [University Hospital, University of Cologne, Department of Internal Medicine III, Cologne (Germany); Deppe, Antje-Christin [University Hospital, University of Cologne, Department of Cardiothoracic Surgery, Cologne (Germany); Matoussevitch, Vladimir [University Hospital, University of Cologne, Department of Vascular Surgery, Cologne (Germany)

    2014-06-15

    To introduce a novel percutaneous technique to stop blood entry at the lesser aortic arch curvature by coil embolisation in type Ia endoleak after TEVAR. A 61-year-old Marfan patient presented with type Ia endoleak of the aortic arch and a growing aortic arch pseudoaneurysm after TEVAR. Multiple preceding operations and interventions made an endovascular approach unsuccessful. Direct percutaneous puncture of the aneurysmal sac would have cured the sign, but not the cause of blood entry at the lesser curvature of the aortic arch. Direct CT-guided percutaneous puncture of the blood entry site in the aortic arch with fluoroscopically guided coil embolisation using detachable extra-long coils was successfully performed. Three weeks after the intervention, the patient developed fever because of superinfection of the pseudoaneurysm. The blood cultures and CT-guided mediastinal aspirate were sterile. After intravenous administration of antibiotics, the fever disappeared and the patient recovered. Six-month follow-up showed permanent closure of the endoleak and a shrinking aneurysmal sac. Direct percutaneous puncture of the aortic arch at the blood entry site of a thoracic type Ia endoleak after TEVAR and double-chimney stent-grafts with coil embolisation of the wedge-shaped space between the lesser aortic curvature and the stent-graft is possible. (orig.)

  12. Thoracic type Ia endoleak: direct percutaneous coil embolization of the aortic arch at the blood entry site after TEVAR and double-chimney stent-grafts

    International Nuclear Information System (INIS)

    Bangard, Christopher; Franke, Mareike; Maintz, David; Chang, De-Hua; Pfister, Roman; Deppe, Antje-Christin; Matoussevitch, Vladimir

    2014-01-01

    To introduce a novel percutaneous technique to stop blood entry at the lesser aortic arch curvature by coil embolisation in type Ia endoleak after TEVAR. A 61-year-old Marfan patient presented with type Ia endoleak of the aortic arch and a growing aortic arch pseudoaneurysm after TEVAR. Multiple preceding operations and interventions made an endovascular approach unsuccessful. Direct percutaneous puncture of the aneurysmal sac would have cured the sign, but not the cause of blood entry at the lesser curvature of the aortic arch. Direct CT-guided percutaneous puncture of the blood entry site in the aortic arch with fluoroscopically guided coil embolisation using detachable extra-long coils was successfully performed. Three weeks after the intervention, the patient developed fever because of superinfection of the pseudoaneurysm. The blood cultures and CT-guided mediastinal aspirate were sterile. After intravenous administration of antibiotics, the fever disappeared and the patient recovered. Six-month follow-up showed permanent closure of the endoleak and a shrinking aneurysmal sac. Direct percutaneous puncture of the aortic arch at the blood entry site of a thoracic type Ia endoleak after TEVAR and double-chimney stent-grafts with coil embolisation of the wedge-shaped space between the lesser aortic curvature and the stent-graft is possible. (orig.)

  13. Bicuspid aortic valves are associated with increased wall and turbulence shear stress levels compared to trileaflet aortic valves.

    Science.gov (United States)

    Saikrishnan, Neelakantan; Mirabella, Lucia; Yoganathan, Ajit P

    2015-06-01

    Congenital bicuspid aortic valves (BAVs) are associated with accelerated disease progression, such as leaflet calcification and ascending aorta dilatation. Although common underlying genetic factors have been implicated in accelerated disease in BAV patients, several studies have suggested that altered hemodynamics also play a role in this disease process. The present study compares turbulence and wall shear stress (WSS) measurements between various BAV and trileaflet aortic valve (TAV) models to provide information for mechanobiological models of BAV disease. BAV and TAV models were constructed from excised porcine aortic valves to simulate parametric variations in BAV stenosis, hemodynamics and geometry. Particle image velocimetry experiments were conducted at physiological pressure conditions to characterize velocity fields in the ascending aorta. The velocity fields were post-processed to calculate turbulence, viscous and wall shear stresses in the ascending aorta. Stenosed BAV models showed the presence of eccentric systolic jets, causing increased WSS. Lower cardiac output resulted in a narrower jet, lower turbulence and lower viscous shear stress (VSS). The specific severe stenosis BAV model studied here showed reduced WSS due to reduction in non-fused leaflet mobility. Dilation of the aorta did not affect any turbulence or VSS, but reduced the WSS. In comparison with BAVs, TAVs have similar VSS values, but much smaller WSS and turbulence levels. These increased turbulence  and WSS levels in BAVs may play a key role in amplifying the biological responses of the ascending aorta wall and valvular leaflets, and support the hemodynamic underpinnings of BAV disease processes.

  14. Magnetic resonance imaging 4-D flow-based analysis of aortic hemodynamics in Turner syndrome

    International Nuclear Information System (INIS)

    Arnold, Raoul; Neu, Marie; Hirtler, Daniel; Gimpel, Charlotte; Markl, Michael; Geiger, Julia

    2017-01-01

    Cardiovascular surveillance is important in Turner syndrome because of the increased risk of aortic dilation and dissection with consecutively increased mortality. To compare 4-D flow MRI for the characterization of aortic 3-D flow patterns, dimensions and vessel wall parameters in pediatric patients with Turner syndrome and age-matched controls. We performed 4-D flow MRI measuring in vivo 3-D blood flow with coverage of the thoracic aorta in 25 patients with Turner syndrome and in 16 female healthy controls (age mean ± standard deviation were 16 ± 5 years and 17 ± 4 years, respectively). Blood flow was visualized by time-resolved 3-D path lines. Visual grading of aortic flow in terms of helices and vortices was performed by two independent observers. Quantitative analysis included measurement of aortic diameters, quantification of peak systolic wall shear stress, pulsatility index and oscillatory shear index at eight defined sites. Patients with Turner syndrome had significantly larger aortic diameters normalized to BSA, increased vortices in the ascending aorta and elevated helix flow in the ascending and descending aorta compared to controls (all P<0.03). Patients with abnormal helical or vortical flow in the ascending aorta had significantly larger diameters of the ascending aorta (P<0.03). Peak systolic wall shear stress, pulsatility index and oscillatory shear index were significantly lower in Turner patients compared to controls (p=0.02, p=0.002 and p=0.01 respectively). Four-dimensional flow MRI provides new insights into the altered aortic hemodynamics and wall shear stress that could have an impact on the development of aortic dissections. (orig.)

  15. Magnetic resonance imaging 4-D flow-based analysis of aortic hemodynamics in Turner syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, Raoul [University Medical Center Heidelberg, Department of Congenital Heart Disease and Pediatric Cardiology, Heidelberg (Germany); Neu, Marie [University Medical Center, Department of Pediatric Hematology/Oncology/Hemostaseology, Mainz (Germany); Hirtler, Daniel [University of Freiburg, Department of Congenital Heart Defects and Pediatric Cardiology, Heart Center, Freiburg im Breisgau (Germany); Gimpel, Charlotte [Center for Pediatrics, Medical Center - University of Freiburg, Department of General Pediatrics, Adolescent Medicine and Neonatology, Freiburg im Breisgau (Germany); Markl, Michael [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Northwestern University, Department of Biomedical Engineering, McCormick School of Engineering, Chicago, IL (United States); Geiger, Julia [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); University Children' s Hospital, Department of Radiology, Zuerich (Switzerland)

    2017-04-15

    Cardiovascular surveillance is important in Turner syndrome because of the increased risk of aortic dilation and dissection with consecutively increased mortality. To compare 4-D flow MRI for the characterization of aortic 3-D flow patterns, dimensions and vessel wall parameters in pediatric patients with Turner syndrome and age-matched controls. We performed 4-D flow MRI measuring in vivo 3-D blood flow with coverage of the thoracic aorta in 25 patients with Turner syndrome and in 16 female healthy controls (age mean ± standard deviation were 16 ± 5 years and 17 ± 4 years, respectively). Blood flow was visualized by time-resolved 3-D path lines. Visual grading of aortic flow in terms of helices and vortices was performed by two independent observers. Quantitative analysis included measurement of aortic diameters, quantification of peak systolic wall shear stress, pulsatility index and oscillatory shear index at eight defined sites. Patients with Turner syndrome had significantly larger aortic diameters normalized to BSA, increased vortices in the ascending aorta and elevated helix flow in the ascending and descending aorta compared to controls (all P<0.03). Patients with abnormal helical or vortical flow in the ascending aorta had significantly larger diameters of the ascending aorta (P<0.03). Peak systolic wall shear stress, pulsatility index and oscillatory shear index were significantly lower in Turner patients compared to controls (p=0.02, p=0.002 and p=0.01 respectively). Four-dimensional flow MRI provides new insights into the altered aortic hemodynamics and wall shear stress that could have an impact on the development of aortic dissections. (orig.)

  16. Aorto-right atrial fistula after Bentall repair.

    Science.gov (United States)

    Howard, Charles E; Velasco, Carlos E; Roullard, Christina P; Rafael, Aldo

    2017-07-01

    We describe a man with the Marfan syndrome and a prior ascending aortic aneurysm resection who presented with knee pain and concern of endocarditis. Transesophageal echocardiogram showed no vegetations, and computed tomography angiogram of the heart showed a possible pseudoaneurysm. Cardiac catheterization and aortogram revealed the diagnosis of an aorto-right atrial fistula, which was then operatively repaired. This case highlights the role that cardiac catheterization with aortogram can play in the detection of aorto-atrial fistula.

  17. Aortic dilatation in patients with Turner's syndrome without structural cardiac anomaly.

    Science.gov (United States)

    Alami Laroussi, Nassiba; Dahdah, Nagib; Dallaire, Frédéric; Thérien, Johanne; Fournier, Anne

    2016-03-01

    Dilatation of the ascending aorta is described in Turner's syndrome with variable prevalence (6.8-32%). Reported series typically include patients with associated cardiac anomalies. To characterise the prevalence, age of onset, and the progress of dilatation of the ascending aorta in Turner's syndrome patients free of structural cardiac anomalies. Potential risk factors such as karyotype and growth hormone therapy were analysed for correlation with aortic dilatation. We carried out a retrospective study with data collected from medical records and echocardiography studies. Patients with Tuner's syndrome followed-up between 1992 and 2010 with at least two echocardiography studies were eligible. Patients with previous cardiac surgery or under anti-hypertensive medication were excluded. Ascending aorta diameter measurements were adjusted for body surface area, and dilatation was defined as Z-score>2. The study population consisted of 44 patients, aged 11.9±7.4 years at the first echocardiogram and 17.9±7.3 years at the last follow-up, with a follow-up duration of 6.0±3.7 years. A total of 13 (29.5%) patients exhibited aortic dilatation during follow-up, suggesting an actuarial estimate of the freedom from aortic dilatation dropping from 86 to 70% and then to 37% at 10, 20, and 30 years of age, respectively. There was no statistically significant impact of karyotype or growth hormone therapy on aortic Z-score progression. The prevalence of dilatation of the ascending aorta in Turner's syndrome patients free of structural aortic anomalies is comparable with published data with associated lesions. Growth hormone therapy and karyotype had no significant impact; however, longitudinal follow-up is warranted.

  18. Anomalous Origin of the Right Coronary Artery from the Left Anterior Descending Coronary Artery in a Patient with Ascending Aortic Aneurysm

    Directory of Open Access Journals (Sweden)

    Ufuk Gürkan

    2012-04-01

    Full Text Available The incidence of coronary artery anomalies has been reported between 0.6 to 1.3% in angiographic series and 0.3% in autopsy series. An isolated single coronary artery (SCA is even a rarer congenital anomaly occurring in approximately 0.02% of the population. The ectopic origin of the right coronary artery (RCA from the left anterior descending (LAD artery is relatively rare and more benign than other types of anomalous origin of the RCAs. We report a case of an adult male patient with SCA anomaly in which the RCA takes off from the mid LAD. To the best of our knowledge, SCA anomaly coinciding with ascending aortic aneurysm which was treated with Bentall operation has never been described before.

  19. Aortic reconstruction with bovine pericardial grafts

    Directory of Open Access Journals (Sweden)

    Silveira Lindemberg Mota

    2003-01-01

    Full Text Available INTRODUCTION: Glutaraldehyde-treated crimped bovine pericardial grafts are currently used in aortic graft surgery. These conduits have become good options for these operations, available in different sizes and shapes and at a low cost. OBJECTIVE:To evaluate the results obtained with bovine pericardial grafts for aortic reconstruction, specially concerning late complications. METHOD: Between January 1995 and January 2002, 57 patients underwent different types of aortic reconstruction operations using bovine pericardial grafts. A total of 29 (50.8% were operated on an urgent basis (mostly acute Stanford A dissection and 28 electively. Thoracotomy was performed in three patients for descending aortic replacement (two patients and aortoplasty with a patch in one. All remaining 54 underwent sternotomy, cardiopulmonary bypass and aortic resection. Deep hypothermia and total circulatory arrest was used in acute dissections and arch operations. RESULTS: Hospital mortality was 17.5%. Follow-up was 24.09 months (18.5 to 29.8 months confidence interval and complication-free actuarial survival curve was 92.3% (standard deviation ± 10.6. Two patients lately developed thoracoabdominal aneurysms following previous DeBakey II dissection and one died from endocarditis. One "patch" aortoplasty patient developed local descending aortic pseudoaneurysm 42 months after surgery. All other patients are asymptomatic and currently clinically evaluated with echocardiography and CT scans, showing no complications. CONCLUSION: Use of bovine pericardial grafts in aortic reconstruction surgery is adequate and safe, with few complications related to the conduits.

  20. Pre- and Postoperative Imaging of the Aortic Root

    Science.gov (United States)

    Chan, Frandics P.; Mitchell, R. Scott; Miller, D. Craig; Fleischmann, Dominik

    2016-01-01

    Three-dimensional datasets acquired using computed tomography and magnetic resonance imaging are ideally suited for characterization of the aortic root. These modalities offer different advantages and limitations, which must be weighed according to the clinical context. This article provides an overview of current aortic root imaging, highlighting normal anatomy, pathologic conditions, imaging techniques, measurement thresholds, relevant surgical procedures, postoperative complications and potential imaging pitfalls. Patients with a range of clinical conditions are predisposed to aortic root disease, including Marfan syndrome, bicuspid aortic valve, vascular Ehlers-Danlos syndrome, and Loeys-Dietz syndrome. Various surgical techniques may be used to repair the aortic root, including placement of a composite valve graft, such as the Bentall and Cabrol procedures; placement of an aortic root graft with preservation of the native valve, such as the Yacoub and David techniques; and implantation of a biologic graft, such as a homograft, autograft, or xenograft. Potential imaging pitfalls in the postoperative period include mimickers of pathologic processes such as felt pledgets, graft folds, and nonabsorbable hemostatic agents. Postoperative complications that may be encountered include pseudoaneurysms, infection, and dehiscence. Radiologists should be familiar with normal aortic root anatomy, surgical procedures, and postoperative complications, to accurately interpret pre- and postoperative imaging performed for evaluation of the aortic root. Online supplemental material is available for this article. ©RSNA, 2015 PMID:26761529

  1. Right Ventricular Pseudoaneurysm Following Endomyocardial Biopsy.

    Science.gov (United States)

    Pita; Santos; Manteiga; Rodriguez; Beiras

    1996-03-01

    Ventricular perforation is an unusual complication after endomyocardial biopsy in heart transplanted patients. We report a case of asymptomatic right ventricular perforation and pseudoaneurysm formation, secondary to endomyocardial biopsy, diagnosed by angiography. The spontaneous obliteration of the pseudoaneurysm was observed.

  2. Delayed Occipital Artery Pseudoaneurysm Following Blunt Force Trauma.

    Science.gov (United States)

    Changa, Abhinav R; Meleis, Ahmed M; Bassani, Luigi

    2016-05-01

    Occipital artery pseudoaneurysms are extremely rare pathologies that manifest after traumatic injury; only 11 cases have been reported in the literature. Because of their low incidence and vague symptoms, the initial diagnosis can be difficult. However, for correctly diagnosed occipital artery pseudoaneurysms, many successful treatment modalities exist. We review the pathology of occipital pseudoaneurysms, elucidate the reasons for their rarity, discuss effective diagnostic measures, and discuss the currently available treatment options. We also present a case of a 16-year-old boy who sustained blunt force trauma in May 2014 and presented 6 months later with a painful, pulsatile mass in the occipital region. The patient underwent surgical resection to alleviate the pain and the potential risk of hemorrhage. He experienced complete resolution of pain and associated symptoms. Our case highlights the fact that occipital swelling, a significant initial sign of pseudoaneurysm development, can be delayed. Therefore, occipital artery pseudoaneurysms cannot be ruled out of the differential diagnosis based on time course alone. Surgical resection is a quick and effective method for relief of severe pain resulting from occipital artery pseudoaneurysms. Although they are rare entities, occipital artery pseudoaneurysms must be considered in the differential diagnosis of cases of pulsatile mass lesions in the posterior scalp. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Fibrinolytic activity is associated with presence of cystic media degeneration in aneurysms of the ascending aorta

    OpenAIRE

    Borges , Luciano F; Gomez , Delphine; Quintana , Mercedes; Leclercq , Anne; Touat , Ziad; Jondeau , Guillaume; Meilhac , Olivier; Jandrot-Perrus , Martine; Gutierrez , Paulo Sampaio; Freymuller , Edna; Vranckx , Roger; Michel , Jean-Baptiste

    2010-01-01

    Abstract Aims Thoracic Ascending Aortic Aneurysms (TAA) are characterized by elastic fibre breakdown and cystic medial degeneration within the aortic media, associated with progressive SMC rarefaction. The TGF-?/Smad2 signaling pathway is involved in this process. Since pericellular fibrinolytic system activation is able to degrade adhesive proteins, activate MMPs, induce SMC disappearance and increase the bio-availability of TGF-?, we explored the plasminergic system in TAA. ...

  4. Traumatic Anterior Cerebral Artery Pseudoaneurysmal Epistaxis.

    Science.gov (United States)

    Liu, Qing Lin; Xue, Hao; Qi, Chang Jing; Zhao, Peng; Wang, Dong Hai; Li, Gang

    2017-04-01

    Pseudoaneurysmal epistaxis is a rare but emergent condition. We report a case of traumatic anterior cerebral artery pseudoaneurysmal epistaxis and review the published literature. A 49-year-old man sustained severe head trauma. He was diagnosed with multiple skull bone fractures, left subdural hematoma, subarachnoid hemorrhage, pneumocephalus, and right frontal hematoma. Subdural hematoma evacuation was done at a local hospital. In the following months, he experienced repeated epistaxis that required nasal packing to stop the bleeding. Digital subtraction angiography showed an anterior cerebral artery pseudoaneurysm protruding into the posterior ethmoid sinus. Embolization of the aneurysm was performed with microcoils, and the parent artery was occluded by thrombosis. The patient presented 1 month later with another epistaxis episode. Digital subtraction angiography showed recanalization of the parent artery and recurrence of the aneurysm. The parent artery was occluded for the second time with coils and Onyx embolic agent. Pseudoaneurysmal epistaxis is rare, and this is the first report of an anterior cerebral artery pseudoaneurysm that manifested with epistaxis. Endovascular intervention has become the first choice of treatment for this disease. The high recurrence rate is the main disadvantage of endovascular intervention. Aneurysm trapping with bypass surgery is another treatment option. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Spontaneous Thrombosis of a Bicuspid Aortic valve due to Primary Antiphospholipid Syndrome

    Directory of Open Access Journals (Sweden)

    Sarah Farrell

    2010-08-01

    Full Text Available We present the case of a 51-year-old man who was admitted as an emergency with spontaneous thrombosis of the aortic valve and ascending aorta. At operation he was found to have a congenitally bicuspid aortic valve and subsequent investigation revealed primary antiphospholipid syndrome. He underwent successful removal of the thrombus combined with mechanical replacement of the aortic valve.

  6. Investigation on the Regional Loss Factor and Its Anisotropy for Aortic Aneurysms

    Directory of Open Access Journals (Sweden)

    Nastaran Shahmansouri

    2016-10-01

    Full Text Available An aortic aneurysm is a lethal arterial disease that mainly occurs in the thoracic and abdominal regions of the aorta. Thoracic aortic aneurysms are prevalent in the root/ascending parts of the aorta and can lead to aortic rupture resulting in the sudden death of patients. Understanding the biomechanical and histopathological changes associated with ascending thoracic aortic aneurysms (ATAAs, this study investigates the mechanical properties of the aorta during strip-biaxial tensile cycles. The loss factor—defined as the ratio of dissipated energy to the energy absorbed during a tensile cycle—the incremental modulus, and their anisotropy indexes were compared with the media fiber compositions for aneurysmal (n = 26 and control (n = 4 human ascending aortas. The aneurysmal aortas were categorized into the aortas with bicuspid aortic valves (BAV and tricuspid aortic valves (TAV. The strip-biaxial loss factor correlates well with the diameter of the aortas with BAV and TAV (for the axial direction, respectively, R2 = 0.71, p = 0.0022 and R2 = 0.54, p = 0.0096. The loss factor increases significantly with patients’ age in the BAV group (for the axial direction: R2 = 0.45, p = 0.0164. The loss factor is isotropic for all TAV quadrants, whereas it is on average only isotropic in the anterior and outer curvature regions of the BAV group. The results suggest that loss factor may be a useful surrogate measure to describe the histopathology of aneurysmal tissue and to demonstrate the differences between ATAAs with the BAV and TAV.

  7. Sex Differences in Phenotypes of Bicuspid Aortic Valve and Aortopathy: Insights From a Large Multicenter, International Registry.

    Science.gov (United States)

    Kong, William K F; Regeer, Madelien V; Ng, Arnold C T; McCormack, Louise; Poh, Kian Keong; Yeo, Tiong Cheng; Shanks, Miriam; Parent, Sarah; Enache, Roxana; Popescu, Bogdan A; Yip, James W; Ma, Lawrence; Kamperidis, Vasileios; van der Velde, Enno T; Mertens, Bart; Ajmone Marsan, Nina; Delgado, Victoria; Bax, Jeroen J

    2017-03-01

    This large multicenter, international bicuspid aortic valve (BAV) registry aimed to define the sex differences in prevalence, valve morphology, dysfunction (aortic stenosis/regurgitation), aortopathy, and complications (endocarditis and aortic dissection). Demographic, clinical, and echocardiographic data at first presentation of 1992 patients with BAV (71.5% men) were retrospectively analyzed. BAV morphology and valve function were assessed; aortopathy configuration was defined as isolated dilatation of the sinus of Valsalva or sinotubular junction, isolated dilatation of the ascending aorta distal to the sinotubular junction, or diffuse dilatation of the aortic root and ascending aorta. New cases of endocarditis and aortic dissection were recorded. There were no significant sex differences regarding BAV morphology and frequency of normal valve function. When presenting with moderate/severe aortic valve dysfunction, men had more frequent aortic regurgitation than women (33.8% versus 22.2%, P <0.001), whereas women were more likely to have aortic stenosis (34.5% versus 44.1%, P <0.001). Men had more frequently isolated dilatation of the sinus of Valsalva or sinotubular junction (14.2% versus 6.7%, P <0.001) and diffuse dilatation of the aortic root and ascending aorta (16.2% versus 7.3%, P <0.001) than women. Endocarditis (4.5% versus 2.5%, P =0.037) and aortic dissections (0.5% versus 0%, P <0.001) occurred more frequently in men. Although there is a male predominance among patients with BAV, men with BAV had more frequently moderate/severe aortic regurgitation at first presentation compared with women, whereas women presented more often with moderate/severe aortic stenosis compared with men. Furthermore, men had more frequent aortopathy than women. © 2017 American Heart Association, Inc.

  8. Surgical treatment of infective endocarditis with aortic and tricuspid valve involvement using cryopreserved aortic and mitral valve allografts.

    Science.gov (United States)

    Ostrovsky, Yury; Spirydonau, Siarhei; Shchatsinka, Mikalai; Shket, Aliaksandr

    2015-05-01

    Surgical treatment of infective and prosthetic endocarditis using allografts gives good results. Aortic allograft implantation is a common technique, while tricuspid valve replacement with a mitral allograft is very rare. Multiple valve disease in case of infective endocarditis is a surgical challenge as such patients are usually in a grave condition and results of surgical treatment are often unsatisfactory. In this article we describe a clinical case of successful surgical treatment in a patient with active infective endocarditis of aortic and tricuspid valve, complicated by an aortic-right ventricular fistula. The aortic valve and ascending aorta were replaced with a cryopreserved aortic allograft; the tricuspid valve was replaced with a cryopreserved mitral allograft. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  9. Bentall Procedure Using Cryopreserved Valved Aortic Homografts

    Science.gov (United States)

    Christenson, Jan T.; Sierra, Jorge; Trindade, Pedro T.; Didier, Dominique; Kalangos, Afksendiyos

    2004-01-01

    The Bentall procedure is the standard operation for patients who have lesions of the ascending aorta associated with aortic valve disease. In many cases, however, mechanical prosthetic conduits are not suitable. There are few reports in the English-language medical literature concerning the mid- to long-term outcome of Bentall operations with cryopreserved homografts. Therefore, we reviewed our experience with this procedure and valved homografts. From January 1997 through December 2002, 21 patients underwent a Bentall operation with cryopreserved homografts at our institution. There were 14 males and 7 females; the mean age was 36 ± 21 years (range, 15–74 years). Eleven patients had undergone previous aortic valve surgery. All patients had aortic dilatation or aneurysms involving the ascending aorta. Indications for surgery included aortic valve stenosis or insufficiency, and aortic valve endocarditis (native valve or prosthetic). One patient had Takayasu's arteritis and 3 had Marfan syndrome. There was 1 hospital death (due to sepsis), but no other major postoperative complications. The mean hospital stay was 14 ± 7 days. Follow-up echocardiographic and computed tomographic scans were performed yearly. The mean follow-up was 34 months (6–72 months). Follow-up imaging revealed no calcifications or degenerative processes related to the homograft. Four patients had minimal valve regurgitation. Two patients died during follow-up. The 3-year actuarial survival rate was 85.7%. Our data suggest that the Bentall procedure with a valved homograft conduit is a safe procedure with excellent mid- to long-term results, comparable to results reported with aortic valve replacement with a homograft. PMID:15745290

  10. Human Thrombin Injection for the Percutaneous Treatment of Iatrogenic Pseudoaneurysms

    International Nuclear Information System (INIS)

    Elford, Julian; Burrell, Christopher; Freeman, Simon; Roobottom, Carl

    2002-01-01

    Purpose: Thrombin injection is becoming well established for the percutaneous management of iatrogenic pseudoaneurysms. All the published series to date use bovine thrombin,and there have been reports of adverse immunologic effects following its use. Our study aimed to assess the efficacy of human thrombin injection for pseudoaneurysm occlusion. Methods:Fourteen patients with iatrogenic pseudoaneurysms underwent a color Doppler ultrasound examination to assess their suitability for percutaneous human thrombin injection. Human thrombin 1000 IU was then injected into the pseudoaneurysm sac under sterile conditions and with ultrasound guidance. A further color Doppler ultrasound examination was performed 24 hr later to confirm occlusion. Results: All 14 pseudoaneurysms were successfully occluded by human thrombin injection. In two cases a second injection of thrombin was required,but there were no other complications, and all pseudoaneurysms remained occluded at 24 hr. Conclusion: Ultrasound-guided human thrombin injection is simple to perform, effective and safe. We recommend that human thrombin becomes the agent of choice for percutaneous injection into iatrogenic pseudoaneurysms

  11. Development of stroke-induced quadriplegia after endovascular repair of blunt aortic injury pseudoaneurysm.

    Science.gov (United States)

    Amoudi, Abdullah S; Merdad, Anas A; Makhdoom, Ahmed Q; Jamjoom, Reda A

    2015-01-01

    Endovascular repair of blunt aortic injury is now a first-line approach in management. This can warrant coverage of the left subclavian artery (LSA), which could lead to posterior strokes. In this case report, we present a severe complication of endovascular repair of a traumatic aortic aneurysm. A 53-year-old man presented with blunt aortic injury, endovascular repair was carried out where the left subclavian artery was covered. The intervention had a 100% technical success. Twelve hours later, he was discovered to have quadriplegia, a CT scan showed a large left cerebellar infarction extending to the medulla oblongata and proximal spinal cord. Strokes complicate 3% of thoracic endovascular aortic repairs, 80% of those strokes occur in patients who had their LSA`s covered. Most patients however, tolerate the coverage. Although our patient had a dominant right vertebral artery, and lacked risks for these strokes, he developed an extensive stroke that left him quadriplegic.

  12. Ruptured superior gluteal artery pseudoaneurysm with hemorrhagic shock: Case report

    Directory of Open Access Journals (Sweden)

    Kerem Seref Corbacioglu

    2016-03-01

    Full Text Available Pseudoaneurysm of the superior gluteal artery (SGA is very rare and the most common causes are blunt or penetrating pelvic traumas. Although pseudoaneurysm can be asymptomatic at the time of initial trauma, it can be symptomatic weeks, months, even years after initial trauma. We present a case of a ruptured superior gluteal artery pseudoaneurysm with hemorrhagic shock twenty days after a bomb injury in the Syria civil war. In addition, we review the anatomy of the SGA, clinical presentation and pitfalls of pseudoaneurysm, and imaging and treatment options. Keywords: Pseudoaneurysm, Superior gluteal artery, Pitfall, Angiography

  13. Type A aortic dissection in Marfan syndrome: extent of initial surgery determines long-term outcome.

    Science.gov (United States)

    Rylski, Bartosz; Bavaria, Joseph E; Beyersdorf, Friedhelm; Branchetti, Emanuela; Desai, Nimesh D; Milewski, Rita K; Szeto, Wilson Y; Vallabhajosyula, Prashanth; Siepe, Matthias; Kari, Fabian A

    2014-04-01

    Data on outcomes after Stanford type A aortic dissection in patients with Marfan syndrome are limited. We investigated the primary surgery and long-term results in patients with Marfan syndrome who suffered aortic dissection. Among 1324 consecutive patients with aortic dissection type A, 74 with Marfan syndrome (58% men; median age, 37 years [first and third quartiles, 29 and 48 years]) underwent surgical repair (85% acute dissections; 68% DeBakey I; 55% composite valved graft, 30% supracoronary ascending replacement, 15% valve-sparing aortic root replacement; 12% total arch replacement; 3% in-hospital mortality) at 2 tertiary centers in the United States and Europe over the past 25 years. The rate of aortic reintervention with resternotomy was 24% (18 of 74) and of descending aorta (thoracic+abdominal) intervention was 30% (22 of 74) at a median follow-up of 8.4 years (first and third quartiles, 2.2 and 12.7 years). Freedom from need for aortic root reoperation in patients who underwent primarily a composite valved graft or valve-sparing aortic root replacement procedure was 95±3%, 88±5%, and 79±5% and in patients who underwent supracoronary ascending replacement was 83±9%, 60±13%, 20±16% at 5, 10, and 20 years. Secondary aortic arch surgery was necessary only in patients with initial hemi-arch replacement. Emergency surgery for type A dissection in patients with Marfan syndrome is associated with low in-hospital mortality. Failure to extend the primary surgery to aortic root or arch repair leads to a highly complex clinical course. Aortic root replacement or repair is highly recommended because supracoronary ascending replacement is associated with a high need (>40%) for root reintervention.

  14. Unexpected death caused by rupture of a dilated aorta in an adult male with aortic coarctation

    DEFF Research Database (Denmark)

    Leth, Peter Mygind; Knudsen, Peter Juel Thiis

    2015-01-01

    Aortic coarctation (AC) is a congenital aortic narrowing. We describe for the first time the findings obtained by unenhanced post mortem computed tomography (PMCT) in a case where the death was caused by cardiac tamponade from a ruptured aneurysmal dilatation of the ascending aorta and the aortic...

  15. Spontaneous aortic dissecting hematoma in two dogs.

    Science.gov (United States)

    Boulineau, Theresa Marie; Andrews-Jones, Lydia; Van Alstine, William

    2005-09-01

    This report describes 2 cases of spontaneous aortic dissecting hematoma in young Border Collie and Border Collie crossbred dogs. Histology was performed in one of the cases involving an unusual splitting of the elastin present within the wall of the aorta, consistent with elastin dysplasia as described in Marfan syndrome in humans. The first case involved a young purebred Border Collie that died suddenly and the second case involved a Border Collie crossbred dog that died after a 1-month history of seizures. Gross lesions included pericardial tamponade with dissection of the ascending aorta in the former case and thoracic cavity hemorrhage, mediastinal hematoma, and aortic dissection in the latter. Histologic lesions in the case of the Border Collie crossbred dog included a dissecting hematoma of the ascending aorta with elastin dysplasia and right axillary arterial intimal proliferation.

  16. Endovascular Management of Iatrogenic Native Renal Arterial Pseudoaneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Sildiroglu, Onur; Saad, Wael E.; Hagspiel, Klaus D.; Matsumoto, Alan H.; Turba, Ulku Cenk, E-mail: Turba@me.com [University of Virginia Health System, Department of Radiology (United States)

    2012-12-15

    Purpose: Our purpose was to evaluate iatrogenic renal pseudoaneurysms, endovascular treatment, and outcomes. Methods: This retrospective study (2003-2011) reported the technical and clinical outcomes of endovascular therapy for renal pseudoaneurysms in eight patients (mean age, 46 (range 24-68) years). Renal parenchymal loss evaluation was based on digital subtraction angiography and computed tomography. Results: We identified eight iatrogenic renal pseudoaneurysm patients with symptoms of hematuria, pain, and hematoma after renal biopsy (n = 3), surgery (n = 3), percutaneous nephrolithotomy (n = 1), and endoscopic shock-wave lithotripsy (n = 1). In six patients, the pseudoaneurysms were small-sized (<20 mm) and peripherally located and were treated solely with coil embolization (n = 5). In one patient, coil embolization was preceded by embolization with 500-700 micron embospheres to control active bleeding. The remaining two patients had large-sized ({>=}50 mm), centrally located renal pseudoaneurysms treated with thrombin {+-} coils. Technical success with immediate bleeding cessation was achieved in all patients. There were no procedure-related deaths or complications (mean follow-up, 23.5 (range, 1-67) months). Conclusions: Treatment of renal pseudoaneurysms using endovascular approach is a relatively safe and viable option regardless of location (central or peripheral) and size of the lesions with minimal renal parenchymal sacrifice.

  17. When operable patients become inoperable: conversion of a surgical aortic valve replacement into transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Olsen, Lene Kjaer; Arendrup, Henrik; Engstrøm, Thomas

    2009-01-01

    . On extracorporal circulation it was reconized that the aortic annulus, the coronary ostiae and the proximal part of the ascending aorta were severely calcified making valve implantation impossible. Surgical closure without valve substitution was estimated to be associated with a high risk of mortality due...

  18. Repair of an aneurysm of the ascending aorta and arch in an infant with Loeys-Dietz syndrome.

    Science.gov (United States)

    Jaiswal, Pratiksha; Shetty, Varun; Patel, Ebrahim; Shetty, Deviprasad

    2018-05-01

    Aortic aneurysms in childhood are rare disease entities and are usually seen in patients with genetic connective tissue disorders such as Marfans, Ehler-Danlos, and Loeys-Dietz syndrome (LDS). Patients affected with LDS present early in life and have a rapid disease progression. We report a case of repair of an ascending and aortic arch aneurysm in an infant with Loeys-Dietz syndrome. © 2018 Wiley Periodicals, Inc.

  19. Aortic ruptures in seat belt wearers.

    Science.gov (United States)

    Arajärvi, E; Santavirta, S; Tolonen, J

    1989-09-01

    Several investigations have indicated that rupture of the thoracic aorta is one of the leading causes of immediate death in victims of road traffic accidents. In Finland in 1983, 92% of front-seat passengers were seat belt wearers on highways and 82% in build-up areas. The mechanisms of rupture of the aorta have been intensively investigated, but the relationship between seat belt wearing and injury mechanisms leading to aortic rupture is still largely unknown. This study comprises 4169 fatally injured victims investigated by the Boards of Traffic Accident Investigation of Insurance Companies during the period 1972 to 1985. Chest injuries were recorded as the main cause of death in 1121 (26.9%) victims, 207 (5.0%) of those victims having worn a seat belt. Aortic ruptures were found at autopsy in 98 victims and the exact information of the location of the aortic tears was available in 68. For a control group, we analyzed 72 randomly chosen unbelted victims who had a fatal aortic rupture in similar accidents. The location of the aortic rupture in unbelted victims was more often in the ascending aorta, especially in drivers, whereas in seat belt wearers the distal descending aorta was statistically more often ruptured, especially in right-front passengers (p less than 0.05). The steering wheel predominated statistically as the part of the car estimated to have caused the injury in unbelted victims (37/72), and some interior part of the car was the most common cause of fatal thoracic impacts in seat belt wearers (48/68) (p less than 0.001). The mechanism of rupture of the aorta in the classic site just distal to the subclavian artery seems to be rapid deceleration, although complex body movements are also responsible in side impact collisions. The main mechanism leading to rupture of the ascending aorta seems to be severe blow to the bony thorax. This also often causes associated thoracic injuries, such as heart rupture and sternal fracture. Injuries in the ascending

  20. Post-traumatic hepatic pseudoaneurysms in children

    Energy Technology Data Exchange (ETDEWEB)

    Sidhu, M.K. [Department of Diagnostic Imaging, Children`s Hospital Oakland, CA (United States); Shaw, D.W.W. [Department of Radiology, Children`s Hospital and Medical Center, Seattle, Washington (United States); Daly, C.P. [Department of Radiology, University of Washington Hospital and Medical Center, Seattle, Washington (United States); Waldhausen, J.H. [Department of Surgery, Children`s Hospital and Medical Center, Seattle, Washington (United States); Coldwell, D. [Department of Radiology, Denver General Hospital, Denver, Colorado (United States)

    1999-01-01

    Background. Post-traumatic hepatic artery pseudoaneurysms are rarely seen in children. Materials and methods. We retrospectively reviewed the radiologic studies and medical records of three patients treated at our institution and reviewed the literature. The patients (ages 5-13 years) presented immediately to 2 months after blunt (two patients) and penetrating (one patient) trauma. The hepatic pseudoaneurysms were discovered during work-up for fever (one patient), gastrointestinal bleeding and hyperbilirubinemia (one patient), or widened mediastinum (one patient) on chest radiograph. In two patients, the diagnosis was initially suspected by computed tomography (CT) examination and confirmed by angiography. In the third patient, the diagnosis was made initially by angiography. All three pseudoaneurysms were treated with transcatheter embolization. Results. All three embolizations were initially technically successful. However, there was recurrence in one case, in which embolization distal to the neck of the pseudoaneurysms was not technically possible. With conservative management, however, the residual lesion demonstrated spontaneous occlusion by ultrasound (US) at 6 months. Conclusion. This uncommon complication of liver trauma in children can have a delayed presentation, can be clinically unsuspected, and can follow blunt or penetrating trauma. Endovascular embolotherapy is the treatment of choice. (orig.) With 3 figs., 22 refs.

  1. Post-traumatic hepatic pseudoaneurysms in children

    International Nuclear Information System (INIS)

    Sidhu, M.K.; Shaw, D.W.W.; Daly, C.P.; Waldhausen, J.H.; Coldwell, D.

    1999-01-01

    Background. Post-traumatic hepatic artery pseudoaneurysms are rarely seen in children. Materials and methods. We retrospectively reviewed the radiologic studies and medical records of three patients treated at our institution and reviewed the literature. The patients (ages 5-13 years) presented immediately to 2 months after blunt (two patients) and penetrating (one patient) trauma. The hepatic pseudoaneurysms were discovered during work-up for fever (one patient), gastrointestinal bleeding and hyperbilirubinemia (one patient), or widened mediastinum (one patient) on chest radiograph. In two patients, the diagnosis was initially suspected by computed tomography (CT) examination and confirmed by angiography. In the third patient, the diagnosis was made initially by angiography. All three pseudoaneurysms were treated with transcatheter embolization. Results. All three embolizations were initially technically successful. However, there was recurrence in one case, in which embolization distal to the neck of the pseudoaneurysms was not technically possible. With conservative management, however, the residual lesion demonstrated spontaneous occlusion by ultrasound (US) at 6 months. Conclusion. This uncommon complication of liver trauma in children can have a delayed presentation, can be clinically unsuspected, and can follow blunt or penetrating trauma. Endovascular embolotherapy is the treatment of choice. (orig.)

  2. Transcatheter aortic valve implantation for a failed bio-bentall in patients with Marfan syndrome.

    Science.gov (United States)

    Beigel, Roy; Siegel, Robert J; Kahlon, Ravi S; Jilaihawi, Hasan; Cheng, Wen; Makkar, Raj R

    2014-01-01

    Patients with Marfan syndrome are at risk for ascending aortic dilation and dissection at the level of the aortic sinuses, making aortic root and valve replacement common. Patients undergoing an aortic root replacement with concomitant replacement of the aortic valve with a bioprosthesis (Bio-Bentall) are predisposed to bioprosthesis failure. Transcatheter aortic valve implantation (TAVI) has become an option for aortic valve replacement, avoiding cardiopulmonary bypass and/or median sternotomy. We present the first 2 reported patients with Marfan syndrome who underwent a valve-in-valve TAVI in the setting of a prior Bio-Bentall. © 2014 S. Karger AG, Basel.

  3. Acute Type A Aortic Dissection Successfully Managed with One-stage Surgery of Total Aortic Arch Replacement with Supra-aortic Transposition Plus Frozen Elephant Trunk Technique

    Directory of Open Access Journals (Sweden)

    Meng-Lin Lee

    2014-09-01

    Full Text Available Acute type A aortic dissection has long been a challenging issue. The surgical techniques traditionally vary with the anatomic extent of the aortic dissection. Simple ascending aortic grafting can be lifesaving, but the lesions beyond the aorta, which include the arch vessels and descending aorta, remain potential hazards. In this paper, we present a patient in which acute type A aortic dissection with lesions extending into descending thoracic aorta was successfully managed by total arch replacement with supra-aortic transposition plus the frozen elephant trunk technique to the descending aorta. A 67-year-old gentleman presented with severe tearing pain from the anterior to posterior chest. Computed tomography confirmed the diagnosis of acute type A dissection extending to the level of the right common iliac artery. An emergent operation was performed as in the aforementioned technique. The surgery went well and the patient was discharged without comorbidities on postoperative day 25. The patient had regular outpatient clinical follow-up. The follow-up computed tomography images showed adequate results with the obliteration of the false lumen. In conclusion, total aortic arch replacement with supra-aortic transposition plus frozen elephant trunk technique is a safe and feasible operative method for patients with detrimental acute type A aortic dissection.

  4. Brain strokes related to aortic aneurysma – the analysis of three cases

    Directory of Open Access Journals (Sweden)

    Pastuszak Żanna

    2017-04-01

    Full Text Available Brain stroke connected with aortic blood flow disturbances is a rare disease and its incidence is difficult to assume. Nevertheless, 10-50% of patients with aortic dissection may not experience any pain. In case of 18-30% patients with aortic dissection neurological signs are first disease presentation and among them ischemic stroke is the most common. The most popular aortic dissection classification is with use of Stanford system. Type A involves the ascending aorta and type B is occurring distal to the subclavian artery. Aortic dissection risk factors include hypertension, cystic medionecrosis, bicuspid aortic valve and Marfan’s or Ehlers-Danlos syndrome.

  5. [Aortic root dilatation rate in pediatric patients with Marfan syndrome treated with losartan].

    Science.gov (United States)

    Mariucci, Elisabetta; Guidarini, Marta; Donti, Andrea; Lovato, Luigi; Wischmeijer, Anita; Angeli, Emanuela; Gargiulo, Gaetano D; Picchio, Fernando M; Bonvicini, Marco

    2015-12-01

    Medical therapy with angiotensin II receptor blockers/angiotensin-converting enzyme inhibitors and/or beta-blockers was reported to reduce aortic root dilatation rates in pediatric patients with Marfan syndrome. No data are available in the literature on losartan effects after 3 years of therapy. The aim of our study was to establish whether losartan reduces aortic root dilatation rates in pediatric patients with Marfan syndrome in the mid and long term. This is a retrospective analysis of 38 pediatric patients with Marfan syndrome followed at the Marfan Clinic of S. Orsola-Malpighi Hospital of the University of Bologna (Italy). Aortic diameters were measured at sinuses of Valsalva and proximal ascending aorta with transthoracic echocardiography. After a mean follow-up of 4.5 ± 2.5 years (range 2-9 years), aortic root z score at sinuses of Valsalva and proximal ascending aorta remained stable. The average annual rate of change in aortic root z score was -0.1 ± 0.4 and 0 ± 0.3 at sinuses of Valsalva and proximal ascending aorta, respectively. The mean dose of losartan was 0.7 ± 0.3 mg/kg/day. Three patients were non-responders, probably because of late beginning or low dose of therapy. Eight patients underwent cardiac surgery (aortic root surgery in 5 and mitral valve repair in 3), all of them started losartan later in life. Despite the retrospective design of the study and the small sample size, a beneficial effect of losartan therapy was observed in pediatric patients with Marfan syndrome in the mid and long term. Late beginning or low doses of losartan can turn off the effects of therapy.

  6. Nicotinamide Phosphoribosyltransferase in Smooth Muscle Cells Maintains Genome Integrity, Resists Aortic Medial Degeneration, and Is Suppressed in Human Thoracic Aortic Aneurysm Disease.

    Science.gov (United States)

    Watson, Alanna; Nong, Zengxuan; Yin, Hao; O'Neil, Caroline; Fox, Stephanie; Balint, Brittany; Guo, Linrui; Leo, Oberdan; Chu, Michael W A; Gros, Robert; Pickering, J Geoffrey

    2017-06-09

    The thoracic aortic wall can degenerate over time with catastrophic consequences. Vascular smooth muscle cells (SMCs) can resist and repair artery damage, but their capacities decline with age and stress. Recently, cellular production of nicotinamide adenine dinucleotide (NAD + ) via nicotinamide phosphoribosyltransferase (Nampt) has emerged as a mediator of cell vitality. However, a role for Nampt in aortic SMCs in vivo is unknown. To determine whether a Nampt-NAD + control system exists within the aortic media and is required for aortic health. Ascending aortas from patients with dilated aortopathy were immunostained for NAMPT, revealing an inverse relationship between SMC NAMPT content and aortic diameter. To determine whether a Nampt-NAD + control system in SMCs impacts aortic integrity, mice with Nampt -deficient SMCs were generated. SMC- Nampt knockout mice were viable but with mildly dilated aortas that had a 43% reduction in NAD + in the media. Infusion of angiotensin II led to aortic medial hemorrhage and dissection. SMCs were not apoptotic but displayed senescence associated-ß-galactosidase activity and upregulated p16, indicating premature senescence. Furthermore, there was evidence for oxidized DNA lesions, double-strand DNA strand breaks, and pronounced susceptibility to single-strand breakage. This was linked to suppressed poly(ADP-ribose) polymerase-1 activity and was reversible on resupplying NAD + with nicotinamide riboside. Remarkably, we discovered unrepaired DNA strand breaks in SMCs within the human ascending aorta, which were specifically enriched in SMCs with low NAMPT. NAMPT promoter analysis revealed CpG hypermethylation within the dilated human thoracic aorta and in SMCs cultured from these tissues, which inversely correlated with NAMPT expression. The aortic media depends on an intrinsic NAD + fueling system to protect against DNA damage and premature SMC senescence, with relevance to human thoracic aortopathy. © 2017 American Heart

  7. Acute intramural hematoma of ascending aorta. CT findings and clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Toshio; Sakuyama, Keiko; Hiekata, Tomizou; Yamanaka, Ikuo [St. Marianna Univ., Kanagawa (Japan). Yokohama Seibu Hospital; Kuroki, Kazunori; Ohyama, Yukio; Ishikawa, Tohru; Kawada, Tadanori; Akashi, Katsuya

    1997-12-01

    The purpose of this study was to describe the CT findings and clinical outcomes of nineteen patients with acute intramural hematoma (IMH) of the ascending aorta. Six patients underwent surgery on the emergency basis (3 patients) due to cardiac tamponade (n=2) and dilated aorta (n=1), and on the elective basis (3 patients) due to patent and enlarging false lumen. Among the 13 patients with medical management, four patients died from complications of IMH during the follow-up period (2 days-2.5 years). Transition to aortic dissection or enlargement of an intimal tear was noted in 5 patients (31%) in 1 to 6 weeks after onset. Three patients died of causes not related to IMH. Six patients had been alive 2 to 9 years after onset. Retrospective review revealed 10 patients (53%) as possible surgical candidates, and the other 9 patients as medically treated patients in the long-term follow-up. The surgical group showed cardiac tamponade or shock in 6 patients on admission and had pericardial effusion in all the patients on the initial CT scan. In the patients with acute IMH of the ascending aorta, surgery should be considered for severe clinical symptoms, pericardial effusion and large size of the ascending aorta (more than 4 cm) on CT scan, and for converting to a typical type A aortic dissection. CT scan had a major role in making an early diagnosis, in depicting a dangerous sign, and in monitoring its progression or resolution of IMH. (author)

  8. Ruptured superior gluteal artery pseudoaneurysm with hemorrhagic shock: Case report.

    Science.gov (United States)

    Corbacioglu, Kerem Seref; Aksel, Gokhan; Yildiz, Altan

    2016-03-01

    Pseudoaneurysm of the superior gluteal artery (SGA) is very rare and the most common causes are blunt or penetrating pelvic traumas. Although pseudoaneurysm can be asymptomatic at the time of initial trauma, it can be symptomatic weeks, months, even years after initial trauma. We present a case of a ruptured superior gluteal artery pseudoaneurysm with hemorrhagic shock twenty days after a bomb injury in the Syria civil war. In addition, we review the anatomy of the SGA, clinical presentation and pitfalls of pseudoaneurysm, and imaging and treatment options.

  9. Comparison of Ultrasound-Guided Thrombin Injection of Iatrogenic Pseudoaneurysms Based on Neck Dimension.

    Science.gov (United States)

    Yang, Ethan Y; Tabbara, Marwan M; Sanchez, Priscila G; Abi-Chaker, Andrew M; Patel, Jaimin; Bornak, Arash; Jones, Keith M; Rey, Jorge

    2018-02-01

    Ultrasound-guided thrombin injection (UGTI) of femoral artery pseudoaneurysms after endovascular procedures is an effective therapy. There is controversy in the literature regarding injecting pseudoaneurysms with short and/or wide necks. This article reports our experience in UGTI of pseudoaneurysms in 1 hospital regarding the efficacy of this treatment in all pseudoaneurysms regardless of the size of the necks. A retrospective review of 46 patients diagnosed between 2011 and 2016 with groin pseudoaneurysms using established duplex ultrasound criteria. Mean age was 68 years (range 27-87). Ten pseudoaneurysms thrombosed spontaneously, 5 were thrombosed by ultrasound-guided compression, and 2 were treated surgically due to disqualifying criteria. In this retrospective review, we analyzed the remaining 29 pseudoaneurysms regarding the dimensions of their neck lengths and outcomes after attempting thrombin injection. The mean aneurysm neck length and width were 1.03 ± 0.9 cm and 0.30 ± 0.1 cm, respectively. All 29 patients were evaluated with respect to pseudoaneurysm size, neck length, neck width, and complexity. Successful treatment of 29 pseudoaneurysms (2 external iliac, 20 common femoral, 2 deep femoral, and 5 superficial femoral) with UGTI was achieved without complications in 100% of the cases, regardless of pseudoaneurysm size, neck dimensions, or complexity. Anticoagulation status did not affect the efficacy of the procedure. Nine of the 29 pseudoaneurysms (31.0%) had neck length less than 0.5 cm. This study demonstrates the safety and efficacy of UGTI in treating iatrogenic pseudoaneurysm in 29 of 29 patients, even in patients with pseudoaneurysm with short neck lengths. Our experiences support injecting all pseudoaneurysms irrespective of dimension. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Anterior Tibial Artery Pseudoaneurysm: Case Report

    Directory of Open Access Journals (Sweden)

    Funda Tor

    2012-06-01

    Full Text Available The aneurysmsatic changes of the infrapopliteal arteries are rarely seen. They are pseudoaneurysms rather than true aneursyms. The most important cause of them is trauma. There is not a standart treatment for infrapopliteal aneursyms. In this study, we have evaluated a case operated for anterior tibial artery pseudoaneurysm developed after penetrant trauma and diagnosed two weeks later. [Cukurova Med J 2012; 37(3.000: 172-175

  11. Early and late outcomes of 1000 minimally invasive aortic valve operations.

    Science.gov (United States)

    Tabata, Minoru; Umakanthan, Ramanan; Cohn, Lawrence H; Bolman, Ralph Morton; Shekar, Prem S; Chen, Frederick Y; Couper, Gregory S; Aranki, Sary F

    2008-04-01

    Minimal access cardiac valve surgery is increasingly utilized. We report our 11-year experience with minimally invasive aortic valve surgery. From 07/96 to 12/06, 1005 patients underwent minimally invasive aortic valve surgery. Early and late outcomes were analyzed. Median patient age was 68 years (range: 24-95), 179 patients (18%) were 80 years or older, 130 patients (13%) had reoperative aortic valve surgery, 86 (8.4%) had aortic root replacement, 62 (6.1%) had concomitant ascending aortic replacement, and 26 (2.6%) had percutaneous coronary intervention on the day of surgery (hybrid procedure). Operative mortality was 1.9% (19/1005). The incidences of deep sternal wound infection, pneumonia and reoperation for bleeding were 0.5% (5/1005), 1.3% (13/1005) and 2.4% (25/1005), respectively. Median length of stay was 6 days and 733 patients (72%) were discharged home. Actuarial survival was 91% at 5 years and 88% at 10 years. In the subgroup of the elderly (> or =80 years), operative mortality was 1.7% (3/179), median length of stay was 8 days and 66 patients (37%) were discharged home. Actuarial survival at 5 years was 84%. There was a significant decreasing trend in cardiopulmonary bypass time, the incidence of bleeding, and operative mortality over time. Minimal access approaches in aortic valve surgery are safe and feasible with excellent outcomes. Aortic root replacement, ascending aortic replacement, and reoperative surgery can be performed with these approaches. These procedures are particularly well-tolerated in the elderly.

  12. Aortic root surgery in Marfan syndrome: Comparison of aortic valve-sparing reimplantation versus composite grafting.

    Science.gov (United States)

    Karck, Matthias; Kallenbach, Klaus; Hagl, Christian; Rhein, Christine; Leyh, Rainer; Haverich, Axel

    2004-02-01

    The objective of this study was to compare the results of aortic valve-sparing reimplantation and aortic root replacement with mechanical valve conduits in patients with Marfan syndrome undergoing operation for aortic root aneurysms. Patients and methods Between March 1979 and April 2002, 119 patients with clinical evidence of Marfan syndrome underwent composite graft replacement with mechanical valve conduits (n = 74) or aortic valve-sparing reimplantation according to David (n = 45). The underlying causes were aortic dissection type A (43 patients) and aneurysms (76 patients). Patients undergoing aortic valve reimplantation were younger compared with patients undergoing composite grafting (28 vs 35 years, P =.002) and had longer intraoperative aortic crossclamp times (125 vs 78 minutes, P valve reimplantation (P =.15). Mean follow-up was 30 months for patients undergoing aortic valve reimplantation and 114 months for patients undergoing composite grafting. Freedom from reoperation and death after 5 years postoperatively was 92% and 89% in patients undergoing composite grafting and 84% and 96% in patients undergoing aortic valve reimplantation (P =.31; P =.54), respectively. Thromboembolic complications or late postoperative bleeding occurred in 17 patients undergoing composite grafting, and an early postoperative event occurred in 1 patient undergoing aortic valve reimplantation. The results of aortic valve reimplantation and composite grafting of the aortic valve and ascending aorta with mechanical valve conduits are similar with regard to early and mid-term postoperative mortality and to the incidence of late reoperations in patients with Marfan syndrome. The low risk of thromboembolic or bleeding complications favors aortic valve reimplantation in these patients.

  13. Pseudoaneurysms secondary to pancreatitis. Report of two cases

    International Nuclear Information System (INIS)

    Carrion, I.; Escalada, J.; Sanchez, J.J.; Pozo, J.A. del

    1998-01-01

    Pseudoaneurysms secondary to pancreatitis are uncommon but are associated with high rates of morbidity and mortality and thus, should bi diagnosed as early as possible. We present two cases of pseudoaneurysm diagnosed in our hospital in a series of 660 patients who were admitted for treatment of pancreatitis between 1991 and 1994. We show the radiologic images, correlating them with the surgical findings and we compare them with those reported in the literature. We also stress the importance of radiology (ultrasonography, computed tomography and angiography) in the early diagnosis of pseudoaneurysms. (Author) 9 refs

  14. Altered aortic shape in bicuspid aortic valve relatives influences blood flow patterns.

    Science.gov (United States)

    Schnell, Susanne; Smith, Danielle A; Barker, Alex J; Entezari, Pegah; Honarmand, Amir R; Carr, Maria L; Malaisrie, S Chris; McCarthy, Patrick M; Collins, Jeremy; Carr, James C; Markl, Michael

    2016-11-01

    Bicuspid aortic valve (BAV) is known to exhibit familial inheritance and is associated with aortopathy and altered aortic haemodynamics. However, it remains unclear whether BAV-related aortopathy can be inherited independently of valve morphology. Four-dimensional flow magnetic resonance imaging for the in vivo assessment of thoracic aortic 3D blood flow was performed in 24 BAV relatives with trileaflet aortic valves (age = 40 ± 14 years) and 15 healthy controls (age = 37 ± 10 years). Data analysis included aortic dimensions, shape (round/gothic/cubic), and 3D blood flow characteristics (semi-quantitative vortex/helix grading and peak velocities). Cubic and gothic aortic shapes were markedly more prevalent in BAV relatives compared with controls (38 vs. 7%). Ascending aorta (AAo) vortex flow in BAV relatives was significantly increased compared with controls (grading = 1.5 ± 1.0 vs. 0.6 ± 0.9, P = 0.015). Aortic haemodynamics were influenced by aortic shape: peak velocities were reduced for gothic aortas vs. round aortas (P = 0.003); vortex flow was increased for cubic aortas in the AAo (P gothic aortas in the AAo and descending aorta (P = 0.003, P = 0.029). Logistic regression demonstrated significant associations of shape with severity of vortex flow in AAo (P < 0.001) and aortic arch (P = 0.016) in BAV relatives. BAV relatives expressed altered aortic shape and increased vortex flow despite the absence of valvular disease or aortic dilatation. These data suggest a heritable component of BAV-related aortopathy affecting aortic shape and aberrant blood flow, independent of valve morphology. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  15. Endovascular Treatment of Traumatic Pseudoaneurysm Presenting as Intractable Epistaxis

    Science.gov (United States)

    Zhang, Chang wei; You, Chao; Mao, Bo yong; Wang, Chao hua; He, Min; Sun, Hong

    2010-01-01

    Objective To investigate the clinical efficacy of individual endovascular management for the treatment of different traumatic pseudoaneurysms presenting as intractable epistaxis. Materials and Methods For 14 consecutive patients with traumatic pseudoaneurysm presenting as refractory epistaxes, 15 endovascular procedures were performed. Digital subtraction angiography revealed that the pseudoaneurysms originated from the internal maxillary artery in eight patients; and all were treated with occlusion of the feeding artery. In six cases, they originated from the internal carotid artery (ICA); out of which, two were managed with detachable balloons, two with covered stents, one by means of cavity embolization, and the remaining one with parent artery occlusion. All of these cases were followed up clinically from six to 18 months, with a mean follow up time of ten months; moreover, three cases were also followed with angiography. Results Complete cessation of bleeding was achieved in all the 15 instances (100%) immediately after the endovascular therapies. Of the six patients who suffered from ICA pseudoaneurysms, one presented with a permanent stroke and one had an episode of rebleeding requiring intervention. Conclusion In patients presenting with a history of craniocerebral trauma, traumatic pseudoaneurysm must be considered as a differential diagnosis. Individual endovascular treatment is a relatively safe, plausible, and reliable means of managing traumatic pseudoaneurysms. PMID:21076585

  16. Computed tomography-based anatomic characterization of proximal aortic dissection with consideration for endovascular candidacy.

    Science.gov (United States)

    Moon, Michael C; Greenberg, Roy K; Morales, Jose P; Martin, Zenia; Lu, Qingsheng; Dowdall, Joseph F; Hernandez, Adrian V

    2011-04-01

    Proximal aortic dissections are life-threatening conditions that require immediate surgical intervention to avert an untreated mortality rate that approaches 50% at 48 hours. Advances in computed tomography (CT) imaging techniques have permitted increased characterization of aortic dissection that are necessary to assess the design and applicability of new treatment paradigms. All patients presenting during a 2-year period with acute proximal aortic dissections who underwent CT scanning were reviewed in an effort to establish a detailed assessment of their aortic anatomy. Imaging studies were assessed in an effort to document the location of the primary proximal fenestration, the proximal and distal extent of the dissection, and numerous morphologic measurements pertaining to the aortic valve, root, and ascending aorta to determine the potential for an endovascular exclusion of the ascending aorta. During the study period, 162 patients presented with proximal aortic dissections. Digital high-resolution preoperative CT imaging was performed on 76 patients, and 59 scans (77%) were of adequate quality to allow assessment of anatomic suitability for treatment with an endograft. In all cases, the dissection plane was detectable, yet the primary intimal fenestration was identified in only 41% of the studies. Scans showed 24 patients (32%) appeared to be anatomically amenable to such a repair (absence of valvular involvement, appropriate length and diameter of proximal sealing regions, lack of need to occlude coronary vasculature). Of the 42 scans that were determined not to be favorable for endovascular repair, the most common exclusion finding was the absence of a proximal landing zone (n = 15; 36%). Appropriately protocoled CT imaging provides detailed anatomic information about the aortic root and ascending aorta, allowing the assessment of which dissections have proximal fenestrations that may be amenable to an endovascular repair. Copyright © 2011 Society for

  17. Transesophageal echocardiographic strain imaging predicts aortic biomechanics: Beyond diameter.

    Science.gov (United States)

    Emmott, Alexander; Alzahrani, Haitham; Alreishidan, Mohammed; Therrien, Judith; Leask, Richard L; Lachapelle, Kevin

    2018-03-11

    Clinical guidelines recommend resection of ascending aortic aneurysms at diameters 5.5 cm or greater to prevent rupture or dissection. However, approximately 40% of all ascending aortic dissections occur below this threshold. We propose new transesophageal echocardiography strain-imaging moduli coupled with blood pressure measurements to predict aortic dysfunction below the surgical threshold. A total of 21 patients undergoing aortic resection were recruited to participate in this study. Transesophageal echocardiography imaging of the aortic short-axis and invasive radial blood pressure traces were taken for 3 cardiac cycles. By using EchoPAC (GE Healthcare, Madison, Wis) and postprocessing in MATLAB (MathWorks, Natick, Mass), circumferential stretch profiles were generated and combined with the blood pressure traces. From these data, 2 in vivo stiffness moduli were calculated: the Cardiac Cycle Pressure Modulus and Cardiac Cycle Stress Modulus. From the resected aortic ring, testing squares were isolated for ex vivo mechanical analysis and histopathology. Each square underwent equibiaxial tensile testing to generate stress-stretch profiles for each patient. Two ex vivo indices were calculated from these profiles (energy loss and incremental stiffness) for comparison with the Cardiac Cycle Pressure Modulus and Cardiac Cycle Stress Modulus. The echo-derived stiffness moduli demonstrate positive significant covariance with ex vivo tensile biomechanical indices: energy loss (vs Cardiac Cycle Pressure Modulus: R 2  = 0.5873, P biomechanics and histopathology, which demonstrates the added benefit of using simple echocardiography-derived biomechanics to stratify patient populations. Copyright © 2018. Published by Elsevier Inc.

  18. Percutaneous thrombin injection for the treatment of a post-pancreatitis pseudoaneurysm

    International Nuclear Information System (INIS)

    Puri, S.; Nicholson, A.A.; Breen, D.J.

    2003-01-01

    Visceral artery pseudoaneurysms are often treated surgically or by transcatheter embolisation. We report a case of a pseudoaneurysm in a patient with chronic pancreatitis, which was successfully occluded by percutaneous injection of thrombin into the pseudoaneurysmal sac as a first-line management. (orig.)

  19. Transcatheter Embolization of Pseudoaneurysms Complicating Pancreatitis

    International Nuclear Information System (INIS)

    Golzarian, Jafar; Nicaise, Nicole; Deviere, Jacques; Ghysels, Marc; Wery, Didier; Dussaussois, Luc; Gansbeke, Daniel van; Struyven, Julien

    1997-01-01

    Purpose: To evaluate the therapeutic role of angiography in patients with pseudoaneurysms complicating pancreatitis. Methods: Thirteen symptomatic pseudoaneurysms were treated in nine patients with pancreatitis. Eight patients had chronic pancreatitis and pseudocyst and one had acute pancreatitis. Clinical presentation included gastrointestinal bleeding in seven patients and epigastric pain without bleeding in two. All patients underwent transcatheter embolization. Results: Transcatheter embolization resulted in symptomatic resolution in all patients. Rebleeding occurred in two patients, 18 and 28 days after embolization respectively, and was successfully treated by repeated emnbolization. One patient with severe pancreatitis died from sepsis 28 days after embolization. Follow-up was then available for eight patients with no relapse of bleeding after a mean follow-up of 32 months (range 9-48 months). Conclusion: Transcatheter embolization is safe and effective in the management of pseudoaneurysms complicating pancreatitis

  20. Management of Iatrogenic Pseudoaneurysms in Patients Undergoing Coronary Artery Bypass Grafting.

    Science.gov (United States)

    Stone, Patrick A; Thompson, Stephanie N; Hanson, Brent; Masinter, David

    2016-05-01

    A plethora of papers have been written regarding postcatheterization femoral pseudoaneurysms. However, literature is lacking on pseudoaneurysmal management in patients undergoing coronary artery bypass grafting (CABG). Thus, we examined if pseudoaneurysms with subsequent CABG can be managed with the same strategies as those not exposed to the intense anticoagulation accompanying CABGs. During a 14-year study period, we retrospectively examined femoral iatrogenic pseudoaneurysms (IPSAs) diagnosed postheart catheterization in patients having a subsequent CABG. Patient information was obtained from electronic medical records and included pseudoaneurysm characteristics, treatment, and resolution. Outcomes of interest included the occurrence of IPSA treatment failures and complications. In the 66 patients (mean age, 66 ± 11 years, 46% male) meeting inclusion criteria, mean dose of heparin received during the CABG procedure was 34 000 ± 23 000 units. The IPSA size distribution was the following: 17% of IPSAs measured 3 cm. Pseudoaneurysms were managed with compression, duplex-guided thrombin injection, and surgical repair (1%, 27%, and 26% of cases, respectively). Thrombin injection and surgical repair were 100% effective at treating pseudoaneurysms, with 1 patient experiencing a surgical site infection postsurgical repair. Observation-only management was employed in 30 (45%) patients. Nine of 30 patients with no intervention beyond observation had duplex documented resolution/thrombosis during follow-up. One patient initially managed by observation required readmission and surgical repair of an enlarging pseudoaneurysm (6 cm growth) following CABG. Management of pseudoaneurysms in patients prior to CABG should be similar to those patients not undergoing intense anticoagulation. In appropriate cases, small aneurysms can be safely observed, while thrombin injections are effective and safe as well. Thus, routine open surgical repair is not routinely required in patients

  1. Type A aortic dissection: Are there CT signs suggestive of valvular involvement?

    Energy Technology Data Exchange (ETDEWEB)

    Platon, Alexandra, E-mail: alexandra.platon@hcuge.ch [Department of Radiology, Emergency Radiology Unit, University Hospital of Geneva, 4 rue Gabrielle-Perret-Gentil, 1211, Geneva (Switzerland); Bernard, Stephane; Perrin, Nils [Department of Radiology, Emergency Radiology Unit, University Hospital of Geneva, 4 rue Gabrielle-Perret-Gentil, 1211, Geneva (Switzerland); Murith, Nicolas [Division of Cardiovascular Surgery, University Hospital of Geneva, 4 rue Gabrielle-Perret-Gentil, 1211, Geneva (Switzerland); John, Gregor [Department of Internal medicine/Geriatrics and Rehabilitation, University Hospital of Geneva, 4 rue Gabrielle-Perret-Gentil, 1211, Geneva (Switzerland); Department of Internal Medicine, Hôpital neuchâtelois, 2300 La Chaux-de-Fonds (Switzerland); Perneger, Thomas [Division of Clinical Epidemiology, University Hospital of Geneva, 4 rue Gabrielle-Perret-Gentil, 1211, Geneva (Switzerland); Rutschmann, Olivier T. [Division of Emergency Medicine, University Hospitals of Geneva and School of Medicine, 4 rue Gabrielle-Perret-Gentil, 1211, Geneva (Switzerland); Poletti, Pierre-Alexandre [Department of Radiology, Emergency Radiology Unit, University Hospital of Geneva, 4 rue Gabrielle-Perret-Gentil, 1211, Geneva (Switzerland)

    2016-11-15

    Highlights: • Non-ECG gated CT rarely shows valve involvement in type A aortic dissection. • Diameters of the aortic root in type A aortic dissection were measured on initial CT. • Sinus of Valsalva diameter >45 mm is 100% specific to predict aortic valve involvement. - Abstract: Aim: To identify the predictive signs of aortic valve involvement on the non-electrocardiogram (ECG)-gated admission computed tomography (CT) of patients with Type A aortic dissection (AD) according to the Stanford classification. Materials and methods: We retrospectively analyzed the non-ECG-gated CT examinations of patients admitted to the emergency department who underwent surgery for Type A AD over a period of 4 years. The diameter of the following structures was calculated as the mean of the smallest and largest diameters (mm) measured in two different planes: aortic annulus, sinus of Valsalva, sinotubular junction, and proximal ascending aorta. These parameters were compared against operative reports in order to determine whether they were predictive of aortic valve involvement. Results: In total, 20 patients (13 men and 7 women) of a mean age of 59.5 years (29–80) were included, 55% of patients (11/20) having surgically proven valvular involvement. The mean diameters (in mm) of the aortic annulus, sinus of Valsalva, sinotubular junction and proximal ascending aorta in the group with (and without, respectively) valvular involvement was 27.7 (26.7), 44.3 (38.1), 42.6 (36.6), and 47.8 (45.9). Only the measurement of the mean diameter of the sinuses of Valsalva was significantly predictive (p = 0.02) of aortic valve involvement. Conclusion: Our findings suggest that measuring the diameter of the sinuses of Valsalva on non-ECG-gated admission CT examinations allows for predicting aortic valve involvement in Type A AD patients.

  2. Type A aortic dissection: Are there CT signs suggestive of valvular involvement?

    International Nuclear Information System (INIS)

    Platon, Alexandra; Bernard, Stephane; Perrin, Nils; Murith, Nicolas; John, Gregor; Perneger, Thomas; Rutschmann, Olivier T.; Poletti, Pierre-Alexandre

    2016-01-01

    Highlights: • Non-ECG gated CT rarely shows valve involvement in type A aortic dissection. • Diameters of the aortic root in type A aortic dissection were measured on initial CT. • Sinus of Valsalva diameter >45 mm is 100% specific to predict aortic valve involvement. - Abstract: Aim: To identify the predictive signs of aortic valve involvement on the non-electrocardiogram (ECG)-gated admission computed tomography (CT) of patients with Type A aortic dissection (AD) according to the Stanford classification. Materials and methods: We retrospectively analyzed the non-ECG-gated CT examinations of patients admitted to the emergency department who underwent surgery for Type A AD over a period of 4 years. The diameter of the following structures was calculated as the mean of the smallest and largest diameters (mm) measured in two different planes: aortic annulus, sinus of Valsalva, sinotubular junction, and proximal ascending aorta. These parameters were compared against operative reports in order to determine whether they were predictive of aortic valve involvement. Results: In total, 20 patients (13 men and 7 women) of a mean age of 59.5 years (29–80) were included, 55% of patients (11/20) having surgically proven valvular involvement. The mean diameters (in mm) of the aortic annulus, sinus of Valsalva, sinotubular junction and proximal ascending aorta in the group with (and without, respectively) valvular involvement was 27.7 (26.7), 44.3 (38.1), 42.6 (36.6), and 47.8 (45.9). Only the measurement of the mean diameter of the sinuses of Valsalva was significantly predictive (p = 0.02) of aortic valve involvement. Conclusion: Our findings suggest that measuring the diameter of the sinuses of Valsalva on non-ECG-gated admission CT examinations allows for predicting aortic valve involvement in Type A AD patients.

  3. Imaging appearances and endovascular management of uncommon pseudoaneurysms

    International Nuclear Information System (INIS)

    Burli, P.; Winterbottom, A.P.; Cousins, C.; Appleton, D.S.; See, T.C.

    2008-01-01

    Pseudoaneurysms are uncommon and their aetiology is varied. They occur in numerous anatomical locations and present with a multitude of clinical presentations sometimes life-threatening. This review describes the causes, sites, and presentations of uncommon pseudoaneurysms, as well as illustrating their diagnostic appearances and endovascular management

  4. Idiopathic pseudoaneurysm in a patient with breast implants

    DEFF Research Database (Denmark)

    Khorasani, Hoda; Eiberg, Jonas; Bigaard, Janne

    2016-01-01

    Aneurysms and pseudoaneurysms of the internal mammary artery (IMA) are rare and the etiology uncertain although iatrogenic causes have been described. A 64-year-old woman suffered hematoma and bleeding from a pseudoaneurysm probably originating from a branch of the right IMA 16 years after breast...

  5. Long-term results of modified Bentall procedure using flanged composite aortic prosthesis.

    Science.gov (United States)

    Tamura, Kiyoshi; Arai, Hirokuni; Kawaguchi, Satoru; Makita, Satoru; Miyagi, Naoto; Watanabe, Taiju; Fujiwara, Tatsuki

    2013-01-01

    We have been using the flanged composite aortic prosthesis and Carrel button technique to re-attach the coronary ostia in aortic root replacement procedures at our institution over the last twenty five years. Our objective was to evaluate the long-term results of aortic root replacement with this technique. A total of 73 patients from January 1984 to August 2010 were included in this study. The median age was 52.7 ± 14.4 years (range 28-80 years). There were 48 male and 25 female patients. 44 patients (60.3%) had annuloaortic ectasia, and 15 patients (20.5%) had acute type A aortic dissection. Marfan syndrome was recognized in 12 patients (16.5%). The early mortality rate was 5.5% (n = 4). Causes of death were multiple organ failures in two patients and sepsis in another two patients. The actuarial survival rate was 84.2% at 5 years, 64.3% at 15 years and 51.9% at 25 years. Only one patient with aortitis needed a reoperation because of coronary pseudoaneurysm after 23 years from the previous operation. This modified Bentall procedure is reliable and safe, with superior long-term survival and a low rate of aortic reoperation.

  6. Determination of entry site for acute type A aortic dissection by initial enhanced CT-scan

    International Nuclear Information System (INIS)

    Mase, Takenori; Narumiya, Chihiro; Aoyama, Takahiko; Nagata, Yoshihisa

    2002-01-01

    Acute type A aortic dissection presents a surgical emergency because conservative therapy is not effective in the majority of instances. Enhanced CT-scan of the chest is commonly available and is considered to be an optimal diagnostic method for this disease. The operative strategy is to resect the primary tear to close the entry site of the aortic dissection and replace it with a tubular Dacron graft. Therefore, the existence of the entry site is important in determining the operative procedure. Based on the numerical value of the enhanced CT-scan inspection, the present study seeks to preoperatively identify the location of the presumed entry site in aortic dissection. From May 1996 to June 1999, 21 consecutive patients (Marfan's syndrome excluded) with acute type A aortic dissection underwent surgical treatment. Nineteen patients were preoperatively examined by enhanced CT-scan: 11 men and 8 women, with a mean age of 61 years. CT-scan slices used for early diagnosis were of the ascending aorta, aortic arch, descending aorta, and thoracoabdominal aorta. The largest diameters of the whole and true lumen were measured from cross-sectional aortic images with a personal computer, and the areas of the whole and true lumen were obtained by the manual tracing method. The true ratio was calculated for the largest diameter and area of the whole lumen. The nineteen patients were divided into two groups according to the location of the entry site based on the operating views. Seven patients with the entry site in the ascending aorta were classified as group A, and twelve patients with the entry site further in the aortic arch and descending aorta were classified as group B. Comparisons were performed by non-parametric analysis. Moreover, a discriminant analysis was applied to evaluate the classification between the two groups. The ratio of the largest diameter of the true lumen in group A at the level of the ascending and descending aorta was significantly greater than that

  7. Determination of entry site for acute type A aortic dissection by initial enhanced CT-scan

    Energy Technology Data Exchange (ETDEWEB)

    Mase, Takenori; Narumiya, Chihiro; Aoyama, Takahiko; Nagata, Yoshihisa [Aichi Medical Univ., Nagakute (Japan). School of Medicine

    2002-01-01

    Acute type A aortic dissection presents a surgical emergency because conservative therapy is not effective in the majority of instances. Enhanced CT-scan of the chest is commonly available and is considered to be an optimal diagnostic method for this disease. The operative strategy is to resect the primary tear to close the entry site of the aortic dissection and replace it with a tubular Dacron graft. Therefore, the existence of the entry site is important in determining the operative procedure. Based on the numerical value of the enhanced CT-scan inspection, the present study seeks to preoperatively identify the location of the presumed entry site in aortic dissection. From May 1996 to June 1999, 21 consecutive patients (Marfan's syndrome excluded) with acute type A aortic dissection underwent surgical treatment. Nineteen patients were preoperatively examined by enhanced CT-scan: 11 men and 8 women, with a mean age of 61 years. CT-scan slices used for early diagnosis were of the ascending aorta, aortic arch, descending aorta, and thoracoabdominal aorta. The largest diameters of the whole and true lumen were measured from cross-sectional aortic images with a personal computer, and the areas of the whole and true lumen were obtained by the manual tracing method. The true ratio was calculated for the largest diameter and area of the whole lumen. The nineteen patients were divided into two groups according to the location of the entry site based on the operating views. Seven patients with the entry site in the ascending aorta were classified as group A, and twelve patients with the entry site further in the aortic arch and descending aorta were classified as group B. Comparisons were performed by non-parametric analysis. Moreover, a discriminant analysis was applied to evaluate the classification between the two groups. The ratio of the largest diameter of the true lumen in group A at the level of the ascending and descending aorta was significantly greater than

  8. Emergency Stenting of a Ruptured Infected Anastomotic Femoral Pseudoaneurysm

    International Nuclear Information System (INIS)

    Klonaris, Chris; Katsargyris, Athanasios; Matthaiou, Alexandros; Giannopoulos, Athanasios; Tsigris, Chris; Papadopouli, Katerina; Tsiodras, Sotiris; Bastounis, Elias

    2007-01-01

    A 74-year-old man presented with a ruptured infected anastomotic femoral pseudoaneurysm. Due to severe medical comorbidities he was considered unsuitable for conventional surgical management and underwent an emergency endovascular repair with a balloon-expandable covered stent. The pseudoaneurysm was excluded successfully and the patient had an uneventful postoperative recovery with long-term suppressive antimicrobials. He remained well for 10 months after the procedure with no signs of recurrent local or systemic infection and finally died from an acute myocardial infarction. To our knowledge, emergency endovascular treatment of a free ruptured bleeding femoral artery pseudoaneurysm has not been documented before in the English literature. This case illustrates that endovascular therapy may be a safe and efficient alternative in the emergent management of ruptured infected anastomotic femoral artery pseudoaneurysms when traditional open surgery is contraindicated

  9. Traumatic brachiocephalic pseudoaneurysm presenting with delayed stroke: case report

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, A.; Gueckel, F. [Department of Radiology, University Hospital Mannheim, Medical Faculty of University Heidelberg (Germany); Meairs, S.; Cornelius, A.; Schwartz, A. [Department of Neurology, University Hospital Mannheim, Medical Faculty of University Heidelberg (Germany)

    2000-10-01

    We report a traumatic pseudoaneurysm of the internal carotid artery bifurcation and subclavian artery with recurrent strokes events in a 19-year-old man. He was admitted with an acute left hemiparesis. His history revealed a similar episode 1 year and a major car accident 3 years previously. Contrast enhanced MR angiography confirmed colour Doppler sonographic findings of a carotid and subclavian artery pseudoaneurysm presumably resulting from seat-belt trauma. The pseudoaneurysm, containing thrombus, was thought to be the source of artery-to-artery embolism. (orig.)

  10. Percutaneous Stent-Graft Repair of a Mycotic Pulmonary Artery Pseudoaneurysm

    International Nuclear Information System (INIS)

    Chou Meichun; Liang Hueilung; Pan Huayban; Yang Chienfang

    2006-01-01

    Ruptured mycotic pulmonary pseudoaneurysm is a lethal complication. Emergent surgical repair is usually recommended, but still associated with a high mortality rate. We present a patient in whom mycotic pulmonary pseudoaneurysm was a complication after surgical lobectomy 2 weeks earlier. This patient had suffered from repeated massive hemoptysis. After emergent surgical repair of the ruptured pulmonary artery stump, another episode of massive hemorrhage occurred. The pulmonary arteriogram revealed a segmental stenosis and a large, wide-necked, lobulated pseudoaneurysm at the left proximal pulmonary artery. We deployed a balloon-expandable stent-graft (48 mm in length mounted on a 12 mm x 40 mm angioplasty balloon) across the stenotic segment and the neck of the pulmonary pseudoaneurysm. Hemostasis was achieved immediately and, under a 4-week antibiotic treatment, patient was transferred to a local hospital for medical care. This case report demonstrates the benefit of minimally invasive endovascular therapy in a critically ill patient. A literature review of the etiology and management of mycotic pulmonary pseudoaneurysm is included

  11. A bulbar artery pseudoaneurysm following traumatic urethral catheterization.

    Science.gov (United States)

    Bettez, Mathieu; Aubé, Melanie; Sherbiny, Mohamed El; Cabrera, Tatiana; Jednak, Roman

    2017-01-01

    Traumatic urethral catheterization may result in a number of serious complications. A rare occurrence is the development of a urethral pseudoaneurysm. We report the case of a 13-year-old male who required placement of a Foley catheter for an orthopedic surgical procedure. The Foley was misplaced in the bulbourethra, resulting in the development of a bulbar artery pseudoaneurysm. Profuse bleeding via the urethra was noted after removal of the catheter, and the patient experienced severe intermittent hematuria during the postoperative period. Cystoscopy revealed a pulsatile mass within the bulbourethra. Angiography confirmed a bulbar artery pseudoaneurysm, which was successfully embolized with resolution of bleeding.

  12. A bulbar artery pseudoaneurysm following traumatic urethral catheterization

    Science.gov (United States)

    Bettez, Mathieu; Aubé, Melanie; Sherbiny, Mohamed El; Cabrera, Tatiana; Jednak, Roman

    2017-01-01

    Traumatic urethral catheterization may result in a number of serious complications. A rare occurrence is the development of a urethral pseudoaneurysm. We report the case of a 13-year-old male who required placement of a Foley catheter for an orthopedic surgical procedure. The Foley was misplaced in the bulbourethra, resulting in the development of a bulbar artery pseudoaneurysm. Profuse bleeding via the urethra was noted after removal of the catheter, and the patient experienced severe intermittent hematuria during the postoperative period. Cystoscopy revealed a pulsatile mass within the bulbourethra. Angiography confirmed a bulbar artery pseudoaneurysm, which was successfully embolized with resolution of bleeding. PMID:28163815

  13. Angular (Gothic) aortic arch leads to enhanced systolic wave reflection, central aortic stiffness, and increased left ventricular mass late after aortic coarctation repair: evaluation with magnetic resonance flow mapping.

    Science.gov (United States)

    Ou, Phalla; Celermajer, David S; Raisky, Olivier; Jolivet, Odile; Buyens, Fanny; Herment, Alain; Sidi, Daniel; Bonnet, Damien; Mousseaux, Elie

    2008-01-01

    We sought to investigate the mechanism whereby a particular deformity of the aortic arch, an angulated Gothic shape, might lead to hypertension late after anatomically successful repair of aortic coarctation. Fifty-five normotensive patients with anatomically successful repair of aortic coarctation and either a Gothic (angulated) or a Romanesque (smooth and rounded) arch were studied with magnetic resonance angiography and flow mapping in both the ascending and descending aortas. Systolic waveforms, central aortic stiffness, and pulse velocity were measured. We hypothesized that arch angulation would result in enhanced systolic wave reflection with loss of energy across the aortic arch, as well as increased central aortic stiffness. Twenty patients were found to have a Gothic, and 35 a Romanesque, arch. Patients with a Gothic arch showed markedly augmented systolic wave reflection (12 +/- 6 vs 5 +/- 0.3 mL, P Gothic arch (5.6 +/- 1.1 vs 4.1 +/- 1 m/s, P Gothic aortic arch is associated with increased systolic wave reflection, as well as increased central aortic stiffness and left ventricular mass index. These findings explain (at least in part) the association between this pattern of arch geometry and late hypertension at rest and on exercise in subjects after coarctation repair.

  14. Pseudoaneurysm of the thoracic aorta sustained during exposure to a tornado diagnosed with ECG-synchronized CT aortography.

    Science.gov (United States)

    Chakraborty, Amit; von Herrmann, Paul F; Embertson, Ryan E; Landwehr, Kevin P; Winkler, Michael A

    2016-01-01

    A case of a tornado victim with a delayed presentation of injury to the aortic isthmus is discussed. Tornado forces resemble the forces of high energy explosions, and the injuries that can occur as a result of these forces can be bizarre. The patient presented with the unique computed tomography (CT) findings of isolated pseudoaneurysm of the thoracic aorta in the absence of other traumatic injury to the thorax. Equivocal results of the initial CT aortogram (CTA) were confirmed with ECG-synchronized CTA (ECG-CTA), demonstrating the superiority of ECG-CTA as compared to standard CTA. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Interventional radiology in the diagnosis, management, and follow-up of pseudoaneurysms.

    LENUS (Irish Health Repository)

    Keeling, A N

    2009-01-01

    Arterial wall disruption, as a consequence of inflammation\\/infection, trauma (penetrating or blunt), or iatrogenic causes, may result in pseudoaneurysm formation. Currently, iatrogenic causes are increasing as a result of the growth of endovascular intervention. The frequency of other causes also seems to be increasing, but this may simply be the result of increased diagnosis by better imaging techniques, such as multidetector contrast-enhanced computed tomography. Clinically, pseudoaneurysms may be silent, may present with local or systemic signs, or can rupture with catastrophic consequences. Open surgical repair, previously the mainstay of treatment, has largely been replaced by image-guided occlusion methods. On the basis of an experience of over 100 pseudoaneurysms, treatments at various anatomical sites, imaging modalities used for accurate diagnosis, current changing therapeutic options for pseudoaneurysm management, approved embolization agents, and clinical follow-up requirements to ensure adequate treatment will be discussed. Image-guided direct percutaneous and endovascular embolization of pseudoaneurysms are established treatment options with favorable success rates and minimal morbidity. The pendulum has now swung from invasive surgical repair of pseudoaneurysms to that of image-guided interventional radiology.

  16. Minimally invasive therapy of pseudoaneurysms of the trunk: application of thrombin.

    Science.gov (United States)

    Schellhammer, Frank; Steinhaus, Daniele; Cohnen, Mathias; Hoppe, Jonas; Mödder, Ulrich; Fürst, Günter

    2008-01-01

    Thrombin injection has been proven to be successful in postcatheterization pseudoaneurysms. However, there are only a few reports on the treatment of pseudoaneurysms of the trunk. We report our first experiences using a percutaneous as well as an endovascular access. Eight iatrogenic pseudoaneurysms of the trunk (aorta, n = 4; pulmonary artery, n = 1; gastroduodenal artery, n = 1; left gastric artery, n = 1, renal artery, n = 1) were treated either percutaneously using CT guidance (n = 3) or via an endovascular access (n = 5). Noninvasive control angiograms were performed at day 1 and weeks 1 and 3 by either CT or MR angiography. The total volume of the pseudoaneurysms was 31.2 +/- 23.1 ml on average, with a mean volume of the perfused aneurysmal lumen of 12.9 +/- 7.2 ml. The maximum diameter was 4.1 +/- 1.39 cm on average. In each case, the aneurysmal neck was not wider than 2 mm. One pseudoaneurysm occluded spontaneously following selective catheterization. The remaining pseudoaneurysms were successfully treated by injection of 765 +/- 438.1 IU thrombin. In one individual, a nontarget embolization occurred, as well as an intervention-associated rupture of a pseudoaneurysm. High-grade stenoses of the donor artery were found in a different case. Only once was the endoluminal access converted to a percutaneous one. Thrombin injection might be a future first-line treatment of vascular lesions such as pseudoaneurysms of the trunk. In our experience both percutanous and endoluminal access are technically feasible and safe. However, further experiences are mandatory, especially concerning the question of dosage and long-term results.

  17. An Incidentally Detected Right Ventricular Pseudoaneurysm

    Directory of Open Access Journals (Sweden)

    Vamsi C. Gaddipati

    2017-01-01

    Full Text Available Ventricular pseudoaneurysm is an uncommon, potentially fatal complication that has been associated with myocardial infarction, cardiac surgery, chest trauma, and infectious processes. Diagnosis can be challenging, as cases are rare and slowly progressing and typically lack identifiable features on clinical presentation. As a result, advanced imaging techniques have become the hallmark of identification. Ahead, we describe a patient who presents with acute decompensated heart failure and was incidentally discovered to have a large right ventricular pseudoaneurysm that developed following previous traumatic anterior rib fracture.

  18. [Marfan syndrome: clinical and pathomorphological restructurings after surgical treatment of aortic aneurysm].

    Science.gov (United States)

    Zhuraev, R K; Zerbino, D D

    2014-01-01

    The authors examined the state of patients suffering from Marfan syndrome (MS) who endured operation for ascending aorta aneurysm with replacement of the ascending aorta and aortic valve (Bentall operation), studying alterations of the skeleton, face, heart and eyes, as well as pathomorphological restructurings in the aortic wall. The study was carried out 7.0 ± 4.2 years after the operation. We examined a total of 39 patients with MS - 27 (69.2%) men and 12 (30.8%) women aged from 22 to 70 years old (average age - 42.1 ± 13.4 years). All patients were operated on for dissecting aneurysm of the ascending aorta accompanied by a considerable degree of aortic valve insufficiency or aortic ostium stenosis. The mean diameter of the aorta at the level of the sinuses of Valsalva amounted to 7.0 ± 1.3 cm (minimal - 5.0 cm, maximal - 12.0 cm), the Z-score prior to operation was 12.7 ± 6.5. The time form making the diagnosis of MS to surgical intervention for aortic aneurysm amounted to 9.6 ± 5.9 years. The condition after operative treatment in all patients was satisfactory, with the haemodynamic indices stable: systolic AP - 133.5 ± 19.1 mm Hg, diastolic AP 85.1 ± 12.9 mm Hg, heart rate 74.8 ± 7.2 bpm. The average systemic score for the symptoms and tests of MS patients amounted to 8.2 ± 3.3 points. Pathohistological alterations of the aorta in patients with Marfan syndrome consisted in pronounced restructuring of the wall with deep irreversible alternative changes. The pathological process extended in the middle aortic layer all alone the length, but not only in the portions of rupture and dissection. The main pathomorphological signs in MS were as follows: focal accumulations of mucoid substances, dystrophic alterations of smooth-muscle cells, ribbon-like anuclear zones, formation of cystlike cavities, alterations of elastic fibres - fragmentation, hyperelastosis, multiplication, thinning and straightening, zones of elastolysis.

  19. Dimensions of the ascending aorta in children and adolescents with repaired Tetralogy of Fallot obtained by cardiac magnetic resonance angiography.

    Science.gov (United States)

    Grothoff, Matthias; Mende, Meinhard; Graefe, Daniel; Daehnert, Ingo; Kostelka, Martin; Hoffmann, Janine; Freyhardt, Patrick; Lehmkuhl, Lukas; Gutberlet, Matthias; Mahler, Anne

    2016-03-01

    Dilatation of the ascending aorta is a common finding in Tetralogy of fallot (TOF). We sought to provide aortic dimensions in children and adolescents after corrected TOF obtained by contrast-enhanced cardiac-magnetic-resonance angiography (CE-CMRA) that could serve as reference values. We enrolled 101 children and adolescents (56 male) with a median age of 10.9 years. All patients underwent CE-CMRA imaging using a 3-dimensional spoiled gradient-echo-sequence. Aortic diameters were measured at the level of the aortic valve (AV), aortic sinus (AS), sino-tubular junction (STJ) and the ascending aorta (AA) and compared with normal values obtained from literature. Sex-specific aortic dimensions are given as percentile curves as well as z scores. Furthermore CMR volumetric and functional parameters as well as clinical and anamnestic data were analyzed to identify parameters that are associated with aortic dilatation. Diameters for aortic size for males were 3.6 + 16.6*BSA(0.5) at the AV level, 7.0 + 19.5*BSA(0.5) at the AS level, 7.0 + 14.4*BSA(0.5) at the STJ level and 7.3 + 15.5*BSA(0.5) at the AA level. Diameters for females were 5.8 + 14.1*BSA(0.5) at the AV level, 7.2 + 17.6*BSA(0.5) at the AS level, 5.2 + 15.4*BSA(0.5) at the STJ level and 2.0 + 17.8*BSA(0.5) at the AA level. All diameters in TOF patients were larger compared with normal values. The postoperative interval and age at examination were the only parameters associated with aortic size at all measured levels. We provide CE-CMRA data of aortic dimensions in children and adolescents after correction of TOF. Our data might be useful for an estimation of the "normal" aortic size in this patient cohort and can serve as a basis for future longitudinal studies adding prognostic data.

  20. Magnetic resonance measurement of turbulent kinetic energy for the estimation of irreversible pressure loss in aortic stenosis.

    Science.gov (United States)

    Dyverfeldt, Petter; Hope, Michael D; Tseng, Elaine E; Saloner, David

    2013-01-01

    The authors sought to measure the turbulent kinetic energy (TKE) in the ascending aorta of patients with aortic stenosis and to assess its relationship to irreversible pressure loss. Irreversible pressure loss caused by energy dissipation in post-stenotic flow is an important determinant of the hemodynamic significance of aortic stenosis. The simplified Bernoulli equation used to estimate pressure gradients often misclassifies the ventricular overload caused by aortic stenosis. The current gold standard for estimation of irreversible pressure loss is catheterization, but this method is rarely used due to its invasiveness. Post-stenotic pressure loss is largely caused by dissipation of turbulent kinetic energy into heat. Recent developments in magnetic resonance flow imaging permit noninvasive estimation of TKE. The study was approved by the local ethics review board and all subjects gave written informed consent. Three-dimensional cine magnetic resonance flow imaging was used to measure TKE in 18 subjects (4 normal volunteers, 14 patients with aortic stenosis with and without dilation). For each subject, the peak total TKE in the ascending aorta was compared with a pressure loss index. The pressure loss index was based on a previously validated theory relating pressure loss to measures obtainable by echocardiography. The total TKE did not appear to be related to global flow patterns visualized based on magnetic resonance-measured velocity fields. The TKE was significantly higher in patients with aortic stenosis than in normal volunteers (p < 0.001). The peak total TKE in the ascending aorta was strongly correlated to index pressure loss (R(2) = 0.91). Peak total TKE in the ascending aorta correlated strongly with irreversible pressure loss estimated by a well-established method. Direct measurement of TKE by magnetic resonance flow imaging may, with further validation, be used to estimate irreversible pressure loss in aortic stenosis. Copyright © 2013 American

  1. Reducing duplex examinations in patients with iatrogenic pseudoaneurysms.

    Science.gov (United States)

    Stone, Patrick A; Aburahma, Ali F; Flaherty, Sarah K

    2006-06-01

    Ultrasound-guided thrombin injection has become the initial treatment of choice for femoral access-related pseudoaneurysms. Patients typically undergo serial duplex examinations to assess for spontaneous resolution of small iatrogenic pseudoaneurysms (IPSAs) (IPSAs (>2.5 cm). We evaluated the impact of a revised treatment algorithm that includes primary treatment of both small (2.5 cm), rather than observation of smaller ones, and attempts to establish a single duplex examination via a point-of-care treatment strategy. We reviewed 105 consecutive patients treated with ultrasound-guided thrombin injection from July 2001 through September 2004. Patient, IPSAs, characteristics, and treatment methods were examined. The number of duplex examinations per patient was evaluated over the treatment interval. Also, published cost data were used to compare primary treatment of small ISPAs vs observation with serial duplex examinations. Successful thrombosis occurred in 103 (98.1%) of 105 treated pseudoaneurysms. No minor or major complications occurred after thrombin injection in either small or large ISPAs, and both failures requiring operation were in the large aneurysm group. The recurrence rate for the series was 1.9% (2/105), and both recurrences were successfully treated with an additional thrombin injection. A single injection was successful in treating 43 (97.7%) of 44 small (IPSAs, and one required a second injection. Patients had an average of 3.3 duplex examinations in our first year of treatment experience, which declined to 1.5 by our third year with the institution of a point-of-care service model for all pseudoaneurysms. Based on this decreased use of duplex examination and an average treatment cohort of 35 IPSA patients per year our institution, we determined this results in a reduction of 35 hours of laboratory time and nearly 70 ultrasounds per year. Similarly for small pseudoaneurysms, a point-of-service primary treatment program rather than observation

  2. Left ventricular lipoma with pseudoaneurysm-like appearance.

    Science.gov (United States)

    Kawarai, Shun-ichi; Yaginuma, Gen-ya; Abe, Kazuo; Hamasaki, Azumi; Ishikawa, Kazunori; Tanaka, Daizo

    2010-06-01

    We describe an extremely rare cardiac lipoma, with electrocardiographic changes in ST segments and T waves, suggesting ischemic heart disease. The abnormal electrocardiogram was identified during a routine physical examination of an asymptomatic 57-year-old man. Coronary angiography showed no stenotic or occlusive lesions in the coronary arteries except that the left anterior descending artery followed a winding course in the apical region. Left ventriculography revealed a pseudoaneurysm-like mass around the apical portion. Computed tomography and magnetic resonance imaging revealed a cardiac lipoma that communicated with the left ventricle and resembled a pseudoaneurysm. After complete resection of the lipoma and left ventricle patch plasty, the postoperative course was uneventful. Histologically, the tumor was an intramyocardiac lipoma with no evidence of malignancy. To our knowledge, we are the first to describe an intramyocardiac lipoma resembling a left ventricle pseudoaneurysm.

  3. Minimally Invasive Therapy of Pseudoaneurysms of the Trunk: Application of Thrombin

    International Nuclear Information System (INIS)

    Schellhammer, Frank; Steinhaus, Daniele; Cohnen, Mathias; Hoppe, Jonas; Moedder, Ulrich; Fuerst, Guenter

    2008-01-01

    Thrombin injection has been proven to be successful in postcatheterization pseudoaneurysms. However, there are only a few reports on the treatment of pseudoaneurysms of the trunk. We report our first experiences using a percutaneous as well as an endovascular access. Eight iatrogenic pseudoaneurysms of the trunk (aorta, n = 4; pulmonary artery, n = 1; gastroduodenal artery, n = 1; left gastric artery, n = 1, renal artery, n = 1) were treated either percutaneously using CT guidance (n = 3) or via an endovascular access (n = 5). Noninvasive control angiograms were performed at day 1 and weeks 1 and 3 by either CT or MR angiography. The total volume of the pseudoaneurysms was 31.2 ± 23.1 ml on average, with a mean volume of the perfused aneurysmal lumen of 12.9 ± 7.2 ml. The maximum diameter was 4.1 ± 1.39 cm on average. In each case, the aneurysmal neck was not wider than 2 mm. One pseudoaneurysm occluded spontaneously following selective catheterization. The remaining pseudoaneurysms were successfully treated by injection of 765 ± 438.1 IU thrombin. In one individual, a nontarget embolization occurred, as well as an intervention-associated rupture of a pseudoaneurysm. High-grade stenoses of the donor artery were found in a different case. Only once was the endoluminal access converted to a percutaneous one. Thrombin injection might be a future first-line treatment of vascular lesions such as pseudoaneurysms of the trunk. In our experience both percutanous and endoluminal access are technically feasible and safe. However, further experiences are mandatory, especially concerning the question of dosage and long-term results

  4. Valve-sparing aortic root replacement in Loeys-Dietz syndrome.

    Science.gov (United States)

    Patel, Nishant D; Arnaoutakis, George J; George, Timothy J; Allen, Jeremiah G; Alejo, Diane E; Dietz, Harry C; Cameron, Duke E; Vricella, Luca A

    2011-08-01

    Loeys-Dietz syndrome (LDS) is a recently recognized aggressive aortic disorder characterized by root aneurysm, arterial tortuosity, hypertelorism, and bifid uvula or cleft palate. The results of prophylactic root replacement using valve-sparing procedures (valve-sparing root replacement [VSRR]) in patients with LDS is not known. We reviewed all patients with clinical and genetic (transforming growth factor-β receptor mutations) evidence of LDS who underwent VSRR at our institution. Echocardiographic and clinical data were obtained from hospital and follow-up clinic records. From 2002 to 2009, 31 patients with a firm diagnosis of LDS underwent VSRR for aortic root aneurysm. Mean age was 15 years, and 24 (77%) were children. One (3%) patient had a bicuspid aortic valve. Preoperative sinus diameter was 3.9±0.8 cm (z score 7.0±2.9) and 2 (6%) had greater than 2+ aortic insufficiency. Thirty patients (97%) underwent reimplantation procedures using a Valsalva graft. There were no operative deaths. Mean follow-up was 3.6 years (range, 0 to 7 years). One patient required late repair of a pseudoaneurysm at the distal aortic anastomosis, and 1 had a conversion to a David reimplantation procedure after a Florida sleeve operation. No patient suffered thromboembolism or endocarditis, and 1 (3%) patient experienced greater than 2+ late aortic insufficiency. No patient required late aortic valve repair or replacement. Loeys-Dietz syndrome is an aggressive aortic aneurysm syndrome that can be addressed by prophylactic aortic root replacement with low operative risk. Valve-sparing procedures have encouraging early and midterm results, similar to those in Marfan syndrome, and are an attractive option for young patients. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  5. [Campylobacter fetus subspecies fetus endoaortitis on a Bentall tube prosthesis. Apropos of a case].

    Science.gov (United States)

    Abassade, P; Crémieux, O; Korach, J M; Templier, F; Morette, C; Wolff, M; Baudouy, P Y; Farge, C

    1994-11-01

    Campylobacter fetus is a rare cause of endocarditis and endoaortitis: the authors believe this to be the second reported case of infection of an intracardiac prosthesis. The patient was a man who had already undergone replacement of the aortic valve and ascending aorta, and a gastrectomy, which were predisposing factors. The portal of entry was not found. The diagnosis was confirmed by positive blood cultures and transoesophageal echocardiography. The outcome was rapidly fatal despite antibiotic therapy and surgery, because of the seriousness of the lesions (pseudo-aneurysm of the aorta ruptured into the right atrium), the precarity of the terrain and surgical difficulties.

  6. Familial Thoracic Aortic Aneurysm with Dissection Presenting as Flash Pulmonary Edema in a 26-Year-Old Man

    Directory of Open Access Journals (Sweden)

    Sabry Omar

    2014-01-01

    Full Text Available We are reporting a case of familial thoracic aortic aneurysm and dissection in a 26-year-old man with no significant past medical history and a family history of dissecting aortic aneurysm in his mother at the age of 40. The patient presented with cough, shortness of breath, and chest pain. Chest X-ray showed bilateral pulmonary infiltrates. CT scan of the chest showed a dissection of the ascending aorta. The patient underwent aortic dissection repair and three months later he returned to our hospital with new complaints of back pain. CT angiography showed a new aortic dissection extending from the left carotid artery through the bifurcation and into the iliac arteries. The patient underwent replacement of the aortic root, ascending aorta, total aortic arch, and aortic valve. The patient recovered well postoperatively. Genetic studies of the patient and his children revealed no mutations in ACTA2, TGFBR1, TGFBR2, TGFB2, MYH11, MYLK, SMAD3, or FBN1. This case report focuses on a patient with familial TAAD and discusses the associated genetic loci and available screening methods. It is important to recognize potential cases of familial TAAD and understand the available screening methods since early diagnosis allows appropriate management of risk factors and treatment when necessary.

  7. Stentgraft Implantation for the Treatment of Postoperative Hepatic Artery Pseudoaneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Pedersoli, F., E-mail: fpedersoli@ukaachen.de; Isfort, P.; Keil, S.; Goerg, F.; Zimmermann, M.; Liebl, M.; Schulze-Hagen, M. [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology (Germany); Schmeding, M. [RWTH Aachen University Hospital, Clinic for General, Visceral and Transplant Surgery (Germany); Kuhl, C. K.; Bruners, P. [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology (Germany)

    2016-04-15

    PurposeHepatic artery pseudoaneurysms are a rare but potentially life-threatening complication of major pancreaticobiliary surgery. We evaluated the safety and efficacy of endovascular stentgraft implantation for the management of such vascular lesions.Materials and MethodsBetween May 2013 and October 2015, ten patients with postoperative hepatic artery pseudoaneurysm, of which eight presented with active hemorrhage, were treated with endovascular stentgraft implantation. All patients had undergone major pancreatic or hepatic surgery before (pylorus-preserving pancreaticoduodenectomy, pancreatectomy, hemihepatectomy, extended hemihepatectomy). The pseudoaneurysms were diagnosed 13–202 days after surgery and were associated with postsurgical complications (e.g., leakage of pancreaticojejunal anastomosis).ResultsIn 9/10 patients, the pseudoaneurysm was completely excluded via stentgraft implantation. In 1/10 patient, the pseudoaneurysm ruptured during the procedure and was successfully treated by immediate open surgery. In 1/10 patient, a second intervention was performed after 6 days because of rebleeding; this was successfully treated by implantation of a second overlapping stentgraft. Mean follow-up time is 51 days. None of the patients died due to stentgraft- or aneurysm-related complications. Further episodes of hemorrhage were not observed. In one patient, clinically asymptomatic complete occlusion of the stentgraft was discovered at follow-up imaging.ConclusionStentgraft implantation is a safe and effective technique to treat hepatic artery pseudoaneurysms related to major pancreatic or hepatic surgery, especially in the setting of acute hemorrhage.

  8. Stentgraft Implantation for the Treatment of Postoperative Hepatic Artery Pseudoaneurysm

    International Nuclear Information System (INIS)

    Pedersoli, F.; Isfort, P.; Keil, S.; Goerg, F.; Zimmermann, M.; Liebl, M.; Schulze-Hagen, M.; Schmeding, M.; Kuhl, C. K.; Bruners, P.

    2016-01-01

    PurposeHepatic artery pseudoaneurysms are a rare but potentially life-threatening complication of major pancreaticobiliary surgery. We evaluated the safety and efficacy of endovascular stentgraft implantation for the management of such vascular lesions.Materials and MethodsBetween May 2013 and October 2015, ten patients with postoperative hepatic artery pseudoaneurysm, of which eight presented with active hemorrhage, were treated with endovascular stentgraft implantation. All patients had undergone major pancreatic or hepatic surgery before (pylorus-preserving pancreaticoduodenectomy, pancreatectomy, hemihepatectomy, extended hemihepatectomy). The pseudoaneurysms were diagnosed 13–202 days after surgery and were associated with postsurgical complications (e.g., leakage of pancreaticojejunal anastomosis).ResultsIn 9/10 patients, the pseudoaneurysm was completely excluded via stentgraft implantation. In 1/10 patient, the pseudoaneurysm ruptured during the procedure and was successfully treated by immediate open surgery. In 1/10 patient, a second intervention was performed after 6 days because of rebleeding; this was successfully treated by implantation of a second overlapping stentgraft. Mean follow-up time is 51 days. None of the patients died due to stentgraft- or aneurysm-related complications. Further episodes of hemorrhage were not observed. In one patient, clinically asymptomatic complete occlusion of the stentgraft was discovered at follow-up imaging.ConclusionStentgraft implantation is a safe and effective technique to treat hepatic artery pseudoaneurysms related to major pancreatic or hepatic surgery, especially in the setting of acute hemorrhage.

  9. Infected aortic aneurysm presenting as prevertebral abscess in magnetic resonance imaging: A case report

    International Nuclear Information System (INIS)

    Yu, Jung Re; Ko, Seong Joo; Heo, Sang Taek; Kim, Jin Seok; Kim, Seung Hyoung

    2013-01-01

    The differential diagnosis of mass-like lesions around the aorta includes saccular pseudoaneurysms and abscesses. A 69-year-old female was admitted with multiple abscesses and fluid collections in several muscles and joints. Methicillin susceptible Staphylococcus aureus was isolated from her blood and pus. Even though she was treated with repeated operations and appropriate antibiotics, her conditions worsened with persistent fever and newly developed abscesses at other sites. Serial enhanced computed tomography (CT) revealed a newly developed saccular abdominal aortic aneurysm in the retroaortic space at the celiac axis level. However, the infected aortic aneurysm mimicked a prevertebral abscess on enhanced spinal magnetic resonance imaging (MRI) due to its heterogeneous signal intensity caused by intraaneurysmal turbulent blood flow. We report to alert the pitfall in the diagnosis of saccular aortic aneurysm using spinal MRI and the importance of serial enhanced CT study in highly suspicious patients.

  10. Low arterial pressure on admission as a predictor of mortality in operated patients with type A aortic dissection

    Directory of Open Access Journals (Sweden)

    Pavlović Katica

    2011-01-01

    Full Text Available Background/Aim. Hypertension is a known predictor of proximal aortic dissection, but it is not commonly present in these patients on presentation. The associations between ascending aorta with left ventricular hypertrophy, cardiovascular risk factors and coronary atherosclerosis, and outcome of these patients are not fully elucidated. Methods. This retrospective study included 55 consecutive patients with acute type A aortic dissection treated surgically in our institution during the last 2 years. The diagnosis was based on imaging studies. Diameter of ascending aorta was measured with echocardiography. Results. The mean age of the patients was 55.4 ± 12.19 years, and 72.7% were men. A history of arterial hypertension was present in 76.4% of the patients. Maximal ascending aorta diameter was 4.09 ± 0.59 cm, while patients with frank aneurysm accounted for 5.5%. Systolic blood pressure on admission was < 150 mmHg in 58.2% of the patients. Diastolic blood pressure on admission was < 90 mmHg in 54.5% of the patients. Mean arterial pressure on admission was 104.9 ± 24.6 mmHg. No correlations were demonstrated between maximal ascending aorta diameter and diameter of the left ventricular wall, any obtained risk factor and with coronary artery atherosclerosis (p > 0.05. After six months 11 (20% patients died, while intrahospital mortality was 72%. According to logistic regression analysis which included traditional risk factors, echo parameters, coronary artery disease and logistic euro scor, mean arterial blood pressure was the independent predictor of a six-month mortality [RR 0.956; CI (0.918-0.994 ; p = 0.024]. Conclusion. In our population the acute type A aortic dissection occurred rarely in the setting of frank ascending aortic aneurysms > 5.0 cm. The majority of patients had a history of arterial hypertension. A history of arterial hypertension was not associated with maximal ascending aorta diameter. Mean arterial blood pressure was the

  11. Management and outcome of bleeding pseudoaneurysm associated with chronic pancreatitis

    Directory of Open Access Journals (Sweden)

    Jan Yi-Yin

    2006-01-01

    Full Text Available Abstract Background A bleeding pseudoaneurysm in patients with chronic pancreatitis is a rare and potentially lethal complication. Optimal treatment of bleeding peripancreatic pseudoaneurysm remains controversial. This study reports on experience at Chang Gung Memorial Hospital (CGMH in managing of bleeding pseudoaneurysms associated with chronic pancreatitis. Methods The medical records of 9 patients (8 males and 1 female; age range, 28 – 71 years; median, 36 years with bleeding pseudoaneurysms associated with chronic pancreatitis treated at CGMH between Aug. 1992 and Sep. 2004 were retrospectively reviewed. Alcohol abuse (n = 7;78% was the predominant predisposing factor. Diagnoses of bleeding pseudoaneurysms were based on angiographic (7/7, computed tomographic (4/7, ultrasound (2/5, and surgical (2/2 findings. Whether surgery or angiographic embolization was performed was primarily based on patient clinical condition. Median follow-up was 38 months (range, 4 – 87 months. Results Abdominal computed tomography revealed bleeding pseudoaneurysms in 4 of 7 patients (57%. Angiography determined correct diagnosis in 7 patients (7/7, 100%. The splenic artery was involved in 5 cases, the pancreaticoduodenal artery in 2, the gastroduodenal artery in 1, and the middle colic artery in 1. Initial treatment was emergency (n = 4 or elective (n = 3 surgery in 7 patients and arterial embolization in 2. Rebleeding was detected after initial treatment in 3 patients. Overall, 5 arterial embolizations and 9 surgical interventions were performed; the respective rates of success of these treatments were 20% (1/5 and 89% (8/9. Five patients developed pseudocysts before treatment (n = 3 or following intervention (n = 2. Pseudocyst formation was identified in 2 of the 3 rebleeding patients. Five patients underwent surgical treatment for associated pseudocysts and bleeding did not recur. One patient died from angiography-related complications. Overall mortality

  12. Magnetic resonance imaging 4-D flow-based analysis of aortic hemodynamics in Turner syndrome.

    Science.gov (United States)

    Arnold, Raoul; Neu, Marie; Hirtler, Daniel; Gimpel, Charlotte; Markl, Michael; Geiger, Julia

    2017-04-01

    Cardiovascular surveillance is important in Turner syndrome because of the increased risk of aortic dilation and dissection with consecutively increased mortality. To compare 4-D flow MRI for the characterization of aortic 3-D flow patterns, dimensions and vessel wall parameters in pediatric patients with Turner syndrome and age-matched controls. We performed 4-D flow MRI measuring in vivo 3-D blood flow with coverage of the thoracic aorta in 25 patients with Turner syndrome and in 16 female healthy controls (age mean ± standard deviation were 16 ± 5 years and 17 ± 4 years, respectively). Blood flow was visualized by time-resolved 3-D path lines. Visual grading of aortic flow in terms of helices and vortices was performed by two independent observers. Quantitative analysis included measurement of aortic diameters, quantification of peak systolic wall shear stress, pulsatility index and oscillatory shear index at eight defined sites. Patients with Turner syndrome had significantly larger aortic diameters normalized to BSA, increased vortices in the ascending aorta and elevated helix flow in the ascending and descending aorta compared to controls (all PTurner patients compared to controls (p=0.02, p=0.002 and p=0.01 respectively). Four-dimensional flow MRI provides new insights into the altered aortic hemodynamics and wall shear stress that could have an impact on the development of aortic dissections.

  13. Heparin surface stent-graft for the treatment of a carotid pseudoaneurysm.

    Science.gov (United States)

    Tsolaki, Elpiniki; Elpiniki, Tsolaki; Salviato, Elisabetta; Rocca, Tiberio; Braccini, Lucia; Galeotti, Roberto; Mascoli, Francesco

    2010-10-01

    Carotid pseudoaneurysms are a rare consequence of carotid surgery, trauma, and infection. Historically, carotid aneurysms and pseudoaneurysms were treated surgically. However, endovascular techniques have recently become a valid alternative for the treatment of carotid pseudoaneurysms. The case of a 57-year-old male patient with a pseudoaneurysm of the right internal carotid artery is described. The patient came to our unit with a painless and pulsatile mass in the neck, which was growing slowly. Five years earlier, he had undergone surgery on a saccular aneurysm located on the distal extracranial segment of the right internal carotid artery. The pseudoaneurysm was successfully treated with a heparin surface Viabahn stent-graft system (Gore AL, Flagstaff, AZ). Heparin surface stent-grafts can be used for the treatment of carotid lesions and may offer protection against intimal hyperplasia and thrombosis. Further studies are needed to evaluate the long-term results. Copyright © 2010 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  14. Aortic Dissection in a Healthy Male Athlete: A Unique Case with Comprehensive Literature Review

    Directory of Open Access Journals (Sweden)

    Balraj Singh

    2016-01-01

    Full Text Available A young otherwise healthy 27-year-old male who has been using anabolic steroids for a long time developed Type I aortic dissection associated with heavy weightlifting. The patient did not have a recent history of trauma to the chest, no history of hypertension, and no illicit drug use. He presented with severe chest pain radiating to back and syncopal event with exertion. Initial vitals were significant for blood pressure of 80/50 mmHg, pulse of 80 beats per minute, respirations of 24 per minute, and oxygen saturation of 92% on room air. Physical exam was significant for elevated jugular venous pressure, muffled heart sounds, and cold extremities with diminished pulses in upper and absent pulses in lower extremities. Bedside echocardiogram showed aortic root dilatation and cardiac tamponade. STAT computed tomography (CT scan of chest revealed dissection of ascending aorta. Cardiothoracic surgery was consulted and patient underwent successful repair of ascending aorta. Hemodynamic stress of weightlifting can predispose to aortic dissection. Aortic dissection is a rare but often catastrophic condition if not diagnosed and managed acutely. Although rare, aortic dissection needs to be in the differential when a young weightlifter presents with chest pain as a delay in diagnosis may be fatal.

  15. Thrombosed false channel in acute aortic dissections

    International Nuclear Information System (INIS)

    Alerci, M.; Dore, R.; Kluzer, A.; Digiulio, G.; D'Andrea, F.; De Agostini, A.

    1987-01-01

    Three cases are reported of acute dissection with complete thrombosis of the false channel, which is a very uncommonevent in DeBakey's I and II type aortic dissections. The 3 patients entered hospital because of severe thoracic pain without any ECG sign of myocardial infarction. Emergency CT showed evidence of pericardial effusion suggesting hemopericardium, enlargement of the ascending aorta and a peripheral semilunar filling defect which caused a slight deformation of the true channel. On precontrast scans, only one case showed inward displacement of peripheral calcifications and high-density aortic wall. No tipical signs of aortic dissection were reported, expect in the first patient - where a double contrast filled lumen, separated by an intimal flap was seen. CT findings are individually discussed. It is emphasized that in all patients more than one CT sign was present at a time. The correct evaluation of these signs together with the clinacal data could lead to the right diagnosis of aortic dissection in spite of the lack of a f???

  16. The treatment of pseudoaneurysms with flow diverters after malignant otitis externa.

    Science.gov (United States)

    Németh, Tamás; Szakács, László; Bella, Zsolt; Majoros, Valéria; Barzó, Pál; Vörös, Erika

    2017-12-01

    Background We report a case of bilateral malignant otitis externa complicated with bilateral petrous internal carotid artery pseudoaneurysms and their successful treatment with a flow diverter. Case report A 68-year-old woman with serious complications of type II diabetes mellitus had malignant otitis externa on the right side. She was treated with combined antibiotic therapy and underwent mastoidectomy for mastoiditis. She presented at our hospital with acute hemorrhage from the right external auditory canal. The emergency computed tomography (CT) angiography revealed a multiobulated pseudoaneurysm at the petrous segment of the right internal carotid artery. The pseudoaneurysm was treated with a 5 × 40-mm Surpass flow diverter. Three months later, she developed a malignant external otitis on the left side. As the infection progressed, a left-sided mastoiditis, a brain abscess, and a pseudoaneurysm at the petrous segment of the left internal carotid artery developed. The pseudoaneurysm caused bleeding from the left ear, and was treated with a 5 × 50-mm Surpass flow diverter. No recurrent bleeding was observed. Four months later, a follow-up angiography showed complete occlusion of the pseudoaneurysm on the left side, but a residual aneurysm could be detected on the right side. One year after the first intervention, the follow-up CT and magnetic resonance angiography revealed the complete occlusion of the aneurysms bilaterally. Conclusion The use of a flow diverter appears to be an efficient and safe method to occlude carotid pseudoaneurysms even in an inflammatory milieu.

  17. Aortic and peripheral blood pressure during isometric and dynamic exercise

    NARCIS (Netherlands)

    Blum, V.; Carrière, E.G.J.; Kolsters, W.; Mosterd, W.L.; Schiereck, P.; Wesseling, K.H.

    1997-01-01

    The purpose of this study was to compare aortic blood pressure (AOR) to peripheral measurements by the Riva-Rocci/Korotkov (RRK) and Finapres continuous finger pressure (FIN) methods during dynamic and static exercise. A tip manometer was introduced in the ascending aorta after coronary angiography

  18. Acute aortic syndromes: definition, prognosis and treatment options.

    Science.gov (United States)

    Carpenter, S W; Kodolitsch, Y V; Debus, E S; Wipper, S; Tsilimparis, N; Larena-Avellaneda, A; Diener, H; Kölbel, T

    2014-04-01

    Acute aortic syndromes (AAS) are life-threatening vascular conditions of the thoracic aorta presenting with acute pain as the leading symptom in most cases. The incidence is approximately 3-5/100,000 in western countries with increase during the past decades. Clinical suspicion for AAS requires immediate confirmation with advanced imaging modalities. Initial management of AAS addresses avoidance of progression by immediate medical therapy to reduce aortic shear stress. Proximal symptomatic lesions with involvement of the ascending aorta are surgically treated in the acute setting, whereas acute uncomplicated distal dissection should be treated by medical therapy in the acute period, followed by surveillance and repeated imaging studies. Acute complicated distal dissection requires urgent invasive treatment and thoracic endovascular aortic repair has become the treatment modality of choice because of favorable outcomes compared to open surgical repair. Intramural hematoma, penetrating aortic ulcers, and traumatic aortic injuries of the descending aorta harbor specific challenges compared to aortic dissection and treatment strategies are not as uniformly defined as in aortic dissection. Moreover these lesions have a different prognosis. Once the acute period of aortic syndrome has been survived, a lifelong medical treatment and close surveillance with repeated imaging studies is essential to detect impending complications which might need invasive treatment within the short-, mid- or long-term.

  19. Bentall procedure using cryopreserved valved aortic homografts: mid- to long-term results.

    Science.gov (United States)

    Christenson, Jan T; Sierra, Jorge; Trindade, Pedro T; Dominique, Didier; Kalangos, Afksendiyos

    2004-01-01

    The Bentall procedure is the standard operation for patients who have lesions of the ascending aorta associated with aortic valve disease. In many cases, however, mechanical prosthetic conduits are not suitable. There are few reports in the English-language medical literature concerning the mid- to long-term outcome of Bentall operations with cryopreserved homografts. Therefore, we reviewed our experience with this procedure and valved homografts. From January 1997 through December 2002, 21 patients underwent a Bentall operation with cryopreserved homografts at our institution. There were 14 males and 7 females; the mean age was 36 +/- 21 years (range, 15-74 years). Eleven patients had undergone previous aortic valve surgery. All patients had aortic dilatation or aneurysms involving the ascending aorta. Indications for surgery included aortic valve stenosis or insufficiency, and aortic valve endocarditis (native valve or prosthetic). One patient had Takayasu's arteritis and 3 had Marfan syndrome. There was 1 hospital death (due to sepsis), but no other major postoperative complications. The mean hospital stay was 14 +/- 7 days. Follow-up echocardiographic and computed tomographic scans were performed yearly. The mean follow-up was 34 months (6-72 months). Follow-up imaging revealed no calcifications or degenerative processes related to the homograft. Four patients had minimal valve regurgitation. Two patients died during follow-up. The 3-year actuarial survival rate was 85.7%. Our data suggest that the Bentall procedure with a valved homograft conduit is a safe procedure with excellent mid- to long-term results, comparable to results reported with aortic valve replacement with a homograft.

  20. Pseudoaneurysms of large arteries associated with AIDS

    Directory of Open Access Journals (Sweden)

    Carlos Eli Piccinato

    Full Text Available BACKGROUND: Several vascular complications are known to occur in association with the acquired immunodeficiency syndrome (AIDS and recent publications have called attention to the development of pseudoaneurysms of large arteries in patients with AIDS. CASE REPORT: We report on 2 patients with AIDS aged 23 and 31 years with pseudoaneurysms of the abdominal aorta and common iliac arteries. After clinical and radiological evaluation by arteriography and computed tomography, the patients were submitted to aneurysmectomy, with the placement of a patch of dacron in the first case and the interposition of a right aorto-iliac and left femoral prosthesis in the second. The second patient developed new aneurysms of the right subclavian and left popliteal arteries 2 months after surgery. Proximal ligation of the right subclavian artery was performed to treat the first aneurysm and resection and interposition of a reversed saphenous vein was carried out to treat the pseudoaneurysm of the popliteal artery. Histopathological examination of the popliteal artery revealed necrotizing arteritis.

  1. Aortic dilatation in Turner syndrome: the role of MRI in early recognition

    International Nuclear Information System (INIS)

    Chalard, Francois; Ferey, Solene; Kalifa, Gabriel; Teinturier, Cecile

    2005-01-01

    Aortic dilatation and dissection are rare but important complications of Turner syndrome that increase the risk of sudden death in young patients. To assess the value of aortic MRI in patients with Turner syndrome; in particular to demonstrate early aortic dilatation. A total of 21 patients with Turner syndrome underwent MRI of the thoracic aorta with measurement of vessel diameter at four levels. Measurements were normal for age in 15 cases, two patients presented with values at the upper limit of normal and four had obvious dilatation of the ascending aorta. All were symptom free. MRI allows the non-invasive demonstration of early aortic dilatation, which may lead to earlier surgery in asymptomatic individuals. (orig.)

  2. Aortic dilatation in Turner syndrome: the role of MRI in early recognition

    Energy Technology Data Exchange (ETDEWEB)

    Chalard, Francois; Ferey, Solene; Kalifa, Gabriel [Saint Vincent de Paul Hospital, Department of Paediatric Radiology, Paris Cedex 14 (France); Teinturier, Cecile [Saint Vincent de Paul Hospital, Department of Paediatric Endocrinology, Paris (France)

    2005-03-01

    Aortic dilatation and dissection are rare but important complications of Turner syndrome that increase the risk of sudden death in young patients. To assess the value of aortic MRI in patients with Turner syndrome; in particular to demonstrate early aortic dilatation. A total of 21 patients with Turner syndrome underwent MRI of the thoracic aorta with measurement of vessel diameter at four levels. Measurements were normal for age in 15 cases, two patients presented with values at the upper limit of normal and four had obvious dilatation of the ascending aorta. All were symptom free. MRI allows the non-invasive demonstration of early aortic dilatation, which may lead to earlier surgery in asymptomatic individuals. (orig.)

  3. Aortic dilatation in Turner syndrome: the role of MRI in early recognition.

    Science.gov (United States)

    Chalard, François; Ferey, Solène; Teinturier, Cécile; Kalifa, Gabriel

    2005-03-01

    Aortic dilatation and dissection are rare but important complications of Turner syndrome that increase the risk of sudden death in young patients. To assess the value of aortic MRI in patients with Turner syndrome; in particular to demonstrate early aortic dilatation. A total of 21 patients with Turner syndrome underwent MRI of the thoracic aorta with measurement of vessel diameter at four levels. Measurements were normal for age in 15 cases, two patients presented with values at the upper limit of normal and four had obvious dilatation of the ascending aorta. All were symptom free. MRI allows the non-invasive demonstration of early aortic dilatation, which may lead to earlier surgery in asymptomatic individuals.

  4. Femoral artery pseudoaneurysm as a complication of angioplasty. How can it be prevented?

    Science.gov (United States)

    Gupta, Prabha Nini; Salam Basheer, Abdul; Sukumaran, Gireesh Gomaty; Padmajan, Sabin; Praveen, Satheesan; Velappan, Praveen; Nair, Bigesh Unnikrishnan; Nair, Sandeep Govindan; Kunjuraman, Usha Kumari; Madthipat, Unnikrishnan; R, Jayadevan

    2013-01-01

    Femoral pseudoaneurysm is a common complication of repeated femoral puncture during cardiac catheterisation. We describe here the development of femoral pseudoaneurysms in a patient with Takayasu's arteritis, which healed in response to conservative treatment, and review the literature on the prevention and treatment of femoral pseudoaneurysm. PMID:27326111

  5. Intrasellar Iatrogenic Carotid Pseudoaneurysm: Endovascular Treatment with a Polytetrafluoroethylene-Covered S tent

    International Nuclear Information System (INIS)

    Vanninen, R. L.; Manninen, H. I.; Rinne, J.

    2003-01-01

    This case illustrates successful treatment of a large postoperative intrasellar pseudoaneurysm with a polytetrafluoroethylene (PTFE)-covered stent. The advantages and potential disadvantages of this novel method of treatment are discussed. A previously healthy 59-year-old man underwent transsphenoidal operative treatment for hypophyseal macroadenoma,complicated by bleeding. On the 17 th postoperative day the patient had profuse arterial bleeding from his nose requiring posterior tamponade. Subsequent angiography of the left internal carotid artery(ICA) revealed a large pseudoaneurysm located intrasellarly, with the orifice in the anteromedial wall in the ophthalmic segment of the ICA.Surgical treatment of the pseudoaneurysm was considered very risky. A12-mm PTFE-covered stent (JoMed, Ulestraten, Netherlands), manually compressed on a PTCA-balloon (Maxxum 4.5/13 mm, Boston Scientific,Ireland) was endovascularly delivered covering the orifice of the pseudoaneurysm. Control angiography immediately after the intervention and one year later revealed no flow into the pseudoaneurysm and the ICA was fully patent. In conclusion, deployment of a PTFE-covered stent proved to be feasible and successful in the treatment of an intrasellariatrogenic ICA pseudoaneurysm. Adequate anticoagulative treatment after the procedure is essential to prevent thrombotic complications

  6. Severe postpartum haemorrhage from ruptured pseudoaneurysm: successful treatment with transcatheter arterial embolization

    Energy Technology Data Exchange (ETDEWEB)

    Soyer, Philippe; Fargeaudou, Yann; Boudiaf, Mourad; Le Dref, Olivier; Rymer, Roland [Hopital Lariboisiere-AP-HP Universite Paris 7, Department of Abdominal Imaging, Paris cedex 10 (France); Morel, Olivier [Hopital Lariboisiere-AP-HP Universite Paris 7, Department of Obstetrics, Paris cedex 10 (France)

    2008-06-15

    The purpose of this retrospective study was to evaluate the role of transcatheter arterial embolization in the management of severe postpartum haemorrhage due to a ruptured pseudoaneurysm and to analyse the clinical symptoms that may suggest a pseudoaneurysm as a cause of postpartum haemorrhage. A retrospective search of our database disclosed seven women with severe postpartum haemorrhage in whom angiography revealed the presence of a uterine or vaginal artery pseudoaneurysm and who were treated using transcatheter arterial embolization. Clinical files were reviewed for possible clinical findings that could suggest pseudoaneurysm as a cause of bleeding. Angiography revealed extravasation of contrast material in five out of seven patients. Transcatheter arterial embolization allowed to control the bleeding in all patients and subsequently achieve vaginal suture in four patients with vaginal laceration. No complications related to transcatheter arterial embolization were noted. Only two patients had uterine atony, and inefficiency of sulprostone was observed in all patients. Transcatheter arterial embolization is an effective and secure technique for the treatment of severe postpartum haemorrhage due to uterine or vaginal artery pseudoaneurysm. Ineffectiveness of suprostone and absence of uterine atony should raise the possibility of a ruptured pseudoaneurysm. (orig.)

  7. Severe postpartum haemorrhage from ruptured pseudoaneurysm: successful treatment with transcatheter arterial embolization

    International Nuclear Information System (INIS)

    Soyer, Philippe; Fargeaudou, Yann; Boudiaf, Mourad; Le Dref, Olivier; Rymer, Roland; Morel, Olivier

    2008-01-01

    The purpose of this retrospective study was to evaluate the role of transcatheter arterial embolization in the management of severe postpartum haemorrhage due to a ruptured pseudoaneurysm and to analyse the clinical symptoms that may suggest a pseudoaneurysm as a cause of postpartum haemorrhage. A retrospective search of our database disclosed seven women with severe postpartum haemorrhage in whom angiography revealed the presence of a uterine or vaginal artery pseudoaneurysm and who were treated using transcatheter arterial embolization. Clinical files were reviewed for possible clinical findings that could suggest pseudoaneurysm as a cause of bleeding. Angiography revealed extravasation of contrast material in five out of seven patients. Transcatheter arterial embolization allowed to control the bleeding in all patients and subsequently achieve vaginal suture in four patients with vaginal laceration. No complications related to transcatheter arterial embolization were noted. Only two patients had uterine atony, and inefficiency of sulprostone was observed in all patients. Transcatheter arterial embolization is an effective and secure technique for the treatment of severe postpartum haemorrhage due to uterine or vaginal artery pseudoaneurysm. Ineffectiveness of suprostone and absence of uterine atony should raise the possibility of a ruptured pseudoaneurysm. (orig.)

  8. Open Treatment of Blunt Injuries of Supra-Aortic Branches: Case Series.

    Science.gov (United States)

    Sladojevic, Milos; Markovic, Miroslav; Ilic, Nikola; Pejkic, Sinisa; Banzic, Igor; Djoric, Predrag; Koncar, Igor; Tomic, Ivan; Davidovic, Lazar

    2016-02-01

    Blunt injuries of the supra-aortic branches are rare entity, and majority of patients die before arrival at the hospital. Those who arrive alive require complex and fast procedure that requires sternotomy. We report 3 successfully managed cases. We report 3 patients with injury of supra-aortic branches. One was treated urgently due to longitudinal rupture on the posterior wall of innominate artery after car accident, and another 2 had chronic false aneurysm located at the very orifice of the right subclavian and left common carotid artery. In first and second patient bypass grafting with a hand-made, Y-shaped, 8-mm Dacron graft from the ascending aorta to the right common carotid and proximal right subclavian artery were performed, whereas in last 1 bypass grafting from the ascending aorta to the cervical part of the left common carotid artery was performed. In our facility, there were no possibilities for any endovascular treatment. When endovascular technology is not available, open surgical repair of blunt injuries of supra-aortic vessels can be performed without complications. No matter to that, endovascular and hybrid procedures should be considered whenever possible. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Normal values of aortic dimensions, distensibility, and pulse wave velocity in children and young adults: a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Voges Inga

    2012-11-01

    Full Text Available Abstract Background Aortic enlargement and impaired bioelasticity are of interest in several cardiac and non-cardiac diseases as they can lead to cardiovascular complications. Cardiovascular magnetic resonance (CMR is increasingly accepted as a noninvasive tool in cardiovascular evaluation. Assessment of aortic anatomy and bioelasticity, namely aortic distensibility and pulse wave velocity (PWV, by CMR is accurate and reproducible and could help to identify anatomical and bioelastic abnormalities of the aorta. However, normal CMR values for healthy children and young adults are lacking. Methods Seventy-one heart-healthy subjects (age 16.4 ± 7.6 years, range 2.3 - 28.3 years were examined using a 3.0 Tesla CMR scanner. Aortic cross-sectional areas and aortic distensibility were measured at four positions of the ascending and descending thoracic aorta. PWV was assessed from aortic blood flow velocity measurements in a aortic segment between the ascending aorta and the proximal descending aorta. The Lambda-Mu-Sigma (LMS method was used to obtain percentile curves for aortic cross-sectional areas, aortic distensibility and PWV according to age. Results Aortic areas, PWV and aortic distensibility (aortic cross-sectional areas: r = 0.8 to 0.9, p  Conclusions This study provides percentile curves for cross-sectional areas, distensibility and pulse wave velocity of the thoracic aorta in children and young adolescents between their 3rd and 29th year of life. These data may serve as a reference for the detection of pathological changes of the aorta in cardiovascular disease.

  10. Impairment of flow-mediated dilation correlates with aortic dilation in patients with Marfan syndrome.

    Science.gov (United States)

    Takata, Munenori; Amiya, Eisuke; Watanabe, Masafumi; Omori, Kazuko; Imai, Yasushi; Fujita, Daishi; Nishimura, Hiroshi; Kato, Masayoshi; Morota, Tetsuro; Nawata, Kan; Ozeki, Atsuko; Watanabe, Aya; Kawarasaki, Shuichi; Hosoya, Yumiko; Nakao, Tomoko; Maemura, Koji; Nagai, Ryozo; Hirata, Yasunobu; Komuro, Issei

    2014-07-01

    Marfan syndrome is an inherited disorder characterized by genetic abnormality of microfibrillar connective tissue proteins. Endothelial dysfunction is thought to cause aortic dilation in subjects with a bicuspid aortic valve; however, the role of endothelial dysfunction and endothelial damaging factors has not been elucidated in Marfan syndrome. Flow-mediated dilation, a noninvasive measurement of endothelial function, was evaluated in 39 patients with Marfan syndrome. Aortic diameter was measured at the aortic annulus, aortic root at the sinus of Valsalva, sinotubular junction and ascending aorta by echocardiography, and adjusted for body surface area (BSA). The mean value of flow-mediated dilation was 6.5 ± 2.4 %. Flow-mediated dilation had a negative correlation with the diameter of the ascending thoracic aorta (AscAd)/BSA (R = -0.39, p = 0.020) and multivariate analysis revealed that flow-mediated dilation was an independent factor predicting AscAd/BSA, whereas other segments of the aorta had no association. Furthermore, Brinkman index had a somewhat greater influence on flow-mediated dilation (R = -0.42, p = 0.008). Although subjects who smoked tended to have a larger AscAd compared with non-smokers (AscA/BSA: 17.3 ± 1.8 versus 15.2 ± 3.0 mm/m(2), p = 0.013), there was no significant change in flow-mediated dilation, suggesting that smoking might affect aortic dilation via an independent pathway. Common atherogenic risks, such as impairment of flow-mediated dilation and smoking status, affected aortic dilation in subjects with Marfan syndrome.

  11. Ultrasound-guided compression repair of pseudoaneurysms of brachial and femoral arteries - 2 cases-

    International Nuclear Information System (INIS)

    Kim, Hak Soo; Choi, Yeon Hyeon; Kim, Ji Eun; Lee, Sang Hoon; Kim, Myung A; Kim, Tae Kyoung; Cho, Jae Min

    1994-01-01

    Ultrasound-guided compression repair of postcatherization pseudoaneurysm has been reported recently. We successfuly treated two cases of cardiac catherization-related pseudoaneurysms of brachial and femoral arteries with compression repair technique under color Doppler US-guidance. We regard US-guided compression repair as a saft and effective first-line treatment for catherization-related pseudoaneurysm

  12. Double splenic artery pseudoaneurysm with pancreatic pseudocyst: A therapeutic stalemate

    Directory of Open Access Journals (Sweden)

    Santhosh Satheesh

    2017-01-01

    Full Text Available Pseudoaneurysm is a rare but a potentially fatal complication associated with chronic pancreatitis. The presence of concomitant aneurysms has been reported rarely and poses a therapeutic challenge owing to the technical difficulty in accessing the distal aneurysm by endovascular means and increased chances of rupture and bleeding. Here, we report an unusual presentation of simultaneous occurrence of two pseudoaneurysms on the splenic artery (SA. A 50-year-old male, a known case of chronic pancreatitis, presented with acute abdomen and a pulsating epigastric lump. A diagnosis of double pseudoaneurysm of SA with a concomitant pseudocyst was made based on contrast-enhanced computed tomography and was confirmed by angiography. The endovascular coil embolization by the standard sandwich-technique was expected to increase the risk of expansion and rupture of the distal pseudoaneurysm, and hence was managed by adapting a modified endovascular technique, following which patient made uneventful recovery. Double pseudoaneurysm of SA associated with chronic pancreatitis is an unusual presentation. Conventional endovascular treatment used for single aneurysm may not be feasible in the presence of two aneurysms, and it needs to be tailored according to the physical site, size, and the anatomy of the vasculature associated with the aneurysms.

  13. Radial pseudoaneurysm following diagnostic coronary angiography

    Directory of Open Access Journals (Sweden)

    Shankar Laudari

    2015-06-01

    Full Text Available The radial artery access has gained popularity as a method of diagnostic coronary catheterization compared to femoral artery puncture in terms of vascular complications and early ambulation. However, very rare complication like radial artery pseudoaneurysm may occur following cardiac catheterization which may give rise to serious consequences. Here, we report a patient with radial pseudoaneurysm following diagnostic coronary angiography. Adequate and correct methodology of compression of radial artery following puncture for maintaining hemostasis is the key to prevention.DOI: http://dx.doi.org/10.3126/jcmsn.v10i3.12776 Journal of College of Medical Sciences-Nepal, 2014, Vol-10, No-3, 48-50

  14. The Acute aortic syndrome – what do we know and what should we know?

    DEFF Research Database (Denmark)

    Houlind, Kim Christian

    . Intramural hematomas (IMH) are often found on CT-scans in patients with typical aortic pain. They are characterized by the presence of a hematoma in the media , but the absence of flow in the false lumen and the absence of a primary intimal tear. An intimal tear may, however, occur secondary to the IMH...... al. International heterogeneity in diagnostic frequency and clinical outcomes of ascending aortic intramural hematoma. J Am Soc Echocardiogr 2007;20:1260-8 4.Nienaber CA, Powell J. Management of Acute Aortic Syndromes. European Heart Journal 2012; 33:26-35...

  15. Thoracic aortic coarctation: MR evaluation and follow-up

    International Nuclear Information System (INIS)

    Papavero, R.; Kastler, B.; Clair, C.; Livolsi, A.; Papavero, R.; Site, O.; Kastler, B.; Clair, C.; Litzler, J.F.; Delabrousse, E.; Scheneider, P.; Bernard, Y.

    2001-01-01

    Purpose: Report our experience in the evaluation and follow-up of thoracic aortic coarctation with MRI and describe its role to estimate trans-stenotic flow. Material and methods: 43 MR examinations were performed in 30 patients (age range 15 days to 73 years) referred to our institution in the last 7 years. Results: MRI visualized the ascending, horizontal and descending portions of the aorta and the supra-aortic vessels in 42/43 patients. MRI clearly identified preoperatively an aortic coarctation in 11/12 cases confirmed by surgery. Postoperatively MRI depicted 4 restenosis and one aneurysm. In 5 patients MRI demonstrated pseudo-coarctation. A significant correlation was established between the maximal trans-stenotic pressure gradient when measured by Doppler US or angiography and the size of the signal void measured on cine-MR images (r=0.72; p<0.01). Conclusion: MRI is a reliable non invasive investigation method for the diagnosis and semi-quantitative evaluation of aortic coarctation particularly when colour Doppler US is not satisfactory. (authors)

  16. Miscellaneous Endovascular Treatment of Ruptured Hepatic Artery Pseudoaneurysms after Pylorus Preserving Pancreaticoduodenectomy

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ung Rae; Lee, Young Hwan [Dept. of Radiology, Daegu Catholic University Medical Center, Catholic of Daegu University School of Medicine, Daegu (Korea, Republic of); Ahn, Eun Joung; Kim, See Hyung; Kim, Young Hwan [Dept. of Radiology, Keimyung University Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of)

    2012-03-15

    To assess the feasibility and safety of the endovascular treatment of ruptured hepatic artery pseudoaneurysms after pylorus preserving pancreaticoduodenectomy (PPPD). Thirteen patients with hepatic artery pseudoaneurysm after PPPD were enrolled. Various endovascular techniques were used depending on the sites and morphologies of the pseudoaneurysms. Five cases were treated by coil embolization, five with stent-graft, one by thrombin injection and coil embolization, one with stent-graft and coil embolization, and one with N-butyl cyanoacrylate (NBCA) injection. Computed tomography scans and liver function test were performed after the procedures. Pseudoaneurysm exclusion and bleeding cessation was achieved in all patients. In four patients that underwent coil or NBCA embolization of the hepatic artery, aspartate transaminase (AST) and alanine transaminase (ALT) were markedly elevated. Two of these four patients with narrowing of the portal vein due to surrounding hematoma died of hepatic infarction or hepatic abscess. In other nine patients, AST and ALT were unchanged. In the 11 surviving patients, normal hepatic function and complete pseudoaneurysm disappearance were achieved during follow-up. Endovascular treatment of ruptured hepatic artery pseudoaneurysms can be considered as a feasible and safe method. However, complete occlusion of the hepatic artery with coils should be avoided in patients with inadequate portal flow.

  17. Arch translocation and the intra-arch elephant-trunk technique with collared graft for extended chronic dissecting aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Ikenaga Shigeru

    2013-01-01

    Full Text Available Abstract Management of extensive, chronic, dissecting aortic aneurysms after prior repair of the ascending aorta presents a technical challenge for surgeons. A symptomatic 64-year-old patient was admitted for elective surgical repair of an aortic annular dilatation, causing severe aortic regurgitation, and a Crawford type II extended thoracoabdominal aneurysm, 4 years after he underwent primary repair of an acute aortic dissection. The aorta was diffusely dilated, and there were no sites beyond the distal aortic arch where anastomosis could be performed. We successfully performed total aortic replacement with a 2-stage strategy, using an arch translocation technique and an intra-arch elephant-trunk technique.

  18. Hybrid treatment of aortic arch disease

    Science.gov (United States)

    Metzger, Patrick Bastos; Rossi, Fabio Henrique; Moreira, Samuel Martins; Issa, Mario; Izukawa, Nilo Mitsuru; Dinkhuysen, Jarbas J.; Spina Neto, Domingos; Kambara, Antônio Massamitsu

    2014-01-01

    Introduction The management of thoracic aortic disease involving the ascending aorta, aortic arch and descending thoracic aorta are technically challenging and is an area in constant development and innovation. Objective To analyze early and midterm results of hybrid treatment of arch aortic disease. Methods Retrospective study of procedures performed from January 2010 to December 2012. The end points were the technical success, therapeutic success, morbidity and mortality, neurologic outcomes, the rate of endoleaks and reinterventions. Results A total of 95 patients treated for thoracic aortic diseases in this period, 18 underwent hybrid treatment and entered in this study. The average ages were 62.3 years. The male was present in 66.7%. The technical and therapeutic success was 94.5% e 83.3%. The perioperative mortality rate of 11.1%. There is any death during one-year follow- up. The reoperation rates were 16.6% due 2 cases of endoleak Ia and one case of endoleak II. There is any occlusion of anatomic or extra anatomic bypass during follow up. Conclusion In our study, the hybrid treatment of aortic arch disease proved to be a feasible alternative of conventional surgery. The therapeutic success rates and re- interventions obtained demonstrate the necessity of thorough clinical follow-up of these patients in a long time. PMID:25714205

  19. Embolization of gastroduodenal artery pseudoaneurysm caused by chronic pancreatitis: a case report

    International Nuclear Information System (INIS)

    Kim, Se Jong; Ko, Kang Seok; Park, Byung Lan; Kim, Byong Geun; Kim, Jae Kyu

    1993-01-01

    Pseudoaneurysm due to chronic pancreatitis is uncommon, but it can cause recurrent and massive hemorrhage. Because of high morbidity and mortality associated with the pseudoaneurysm, early detection and treatment is essential. Surgical ligation or resection of the aneurysm has a high mortality and therefore, transcatheter embolization is preferably carried out. We report a case in which gastroduodenal artery pseudoaneurysm caused by chronic pancreatitis was successfully treated by transcatheter embolization using Gelfoam and Gianturco spring coils

  20. Embolization of gastroduodenal artery pseudoaneurysm caused by chronic pancreatitis: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Se Jong; Ko, Kang Seok; Park, Byung Lan; Kim, Byong Geun [Kwangju Christian Hospital, Gwangju (Korea, Republic of); Kim, Jae Kyu [College of Medicine, Chonnam National Univrsity, Gwangju (Korea, Republic of)

    1993-01-15

    Pseudoaneurysm due to chronic pancreatitis is uncommon, but it can cause recurrent and massive hemorrhage. Because of high morbidity and mortality associated with the pseudoaneurysm, early detection and treatment is essential. Surgical ligation or resection of the aneurysm has a high mortality and therefore, transcatheter embolization is preferably carried out. We report a case in which gastroduodenal artery pseudoaneurysm caused by chronic pancreatitis was successfully treated by transcatheter embolization using Gelfoam and Gianturco spring coils.

  1. Pseudoaneurysm of the superior gluteal artery following polytrauma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dennis [Vancouver General Hospital, University of British Columbia and Department of Radiology, Vancouver, BC (Canada); Legiehn, Gerald M. [Vancouver General Hospital, Interventional Radiology, University of British Columbia and Department of Radiology, Vancouver, BC (Canada); Munk, Peter L. [Vancouver General Hospital, MSK Section, University of British Columbia and Department of Radiology, Vancouver, BC (Canada)

    2007-09-15

    Gluteal artery aneurysms are rare and often secondary to pelvic fractures, blunt or penetrating trauma. We describe a case of a superior gluteal artery pseudoaneurysm that presented as back pain with numbness and weakness of the lower extremities. Diagnosis was confirmed by color Doppler sonography and angiography. A proximal and distal control was obtained over the aneurysm neck via coil embolization with excellent hemostasis within the pseudoaneurysm and maintenance of perfusion to the left pelvis. (orig.)

  2. Pseudoaneurysm of the superior gluteal artery following polytrauma

    International Nuclear Information System (INIS)

    Lee, Dennis; Legiehn, Gerald M.; Munk, Peter L.

    2007-01-01

    Gluteal artery aneurysms are rare and often secondary to pelvic fractures, blunt or penetrating trauma. We describe a case of a superior gluteal artery pseudoaneurysm that presented as back pain with numbness and weakness of the lower extremities. Diagnosis was confirmed by color Doppler sonography and angiography. A proximal and distal control was obtained over the aneurysm neck via coil embolization with excellent hemostasis within the pseudoaneurysm and maintenance of perfusion to the left pelvis. (orig.)

  3. Delayed presentation of a traumatic brachial artery pseudoaneurysm.

    LENUS (Irish Health Repository)

    Forde, James C

    2009-09-01

    Delayed presentation of a brachial artery pseudoaneurysm following penetrating trauma is infrequently reported. We report the case of a 23-year-old male who presented three months following a penetrating trauma to his antecubital fossa with a sudden exacerbation of swelling and tenderness of his elbow. Doppler ultrasound and computed tomography arteriography confirmed the presence of a large pseudoaneurysm. Surgical reconstruction was performed using the long saphenous vein as an interposition vein graft, restoring normal arterial circulation.

  4. Left ventricular pseudoaneurysm versus aneurysm a diagnosis dilemma

    Directory of Open Access Journals (Sweden)

    Samarjit Bisoyi

    2016-01-01

    Full Text Available Free wall rupture of the left ventricle (LV is a rare but life-threatening complication of acute myocardial infaction. Very rarely such rupture may be contained by the adhering pericardium creating a pseudoaneurysm. This condition warrants for an emergency surgery. Left ventricular aneurysm is the discrete thinning of the ventricular wall (<5 mm with akinetic or dyskinetic wall motion causing an out-pouching of the ventricle. Given the propensity for pseudoaneurysms to rupture leading to cardiac tamponade, shock, and death, compared with a more benign natural history for true aneurysms, accurate diagnosis of these conditions is important. True aneurysm, usually, calls for an elective surgery. Clinically differentiating the two conditions remains a challenge. We report the case of a patient with LV pseudoaneurysm, initially diagnosed as true aneurysm at our institution. We have attempted to review the existing literature and discussed the characteristic findings of each entity.

  5. Coil Migration after Transarterial Coil Embolization of a Splenic Artery Pseudoaneurysm

    Directory of Open Access Journals (Sweden)

    Bezawit D. Tekola

    2013-11-01

    Full Text Available A 48-year-old man with a history of splenic artery pseudoaneurysm requiring transarterial embolization 3 months earlier presented to the emergency department with abdominal pain and fever. Computed tomography showed evidence of embolization coil fragments within the gastrointestinal tract. Upper endoscopy showed a large gastric ulcer with numerous embolization coils extruding into the gastric lumen. The patient underwent partial gastrectomy, distal pancreatectomy and resection of the splenic artery pseudoaneurysm. This case illustrates a rare delayed complication of transarterial embolization of a splenic artery pseudoaneurysm.

  6. Aortic valve-sparing surgery in Marfan syndrome.

    Science.gov (United States)

    Nachum, Eyal; Shinfeld, Amichay; Kogan, Alexander; Preisman, Sergey; Levin, Shany; Raanani, Ehud

    2013-08-01

    Patients with Marfan syndrome are referred for cardiac surgery due to root aneurysm with or without aortic valve regurgitation. Because these patients are young and frequently present with normal-appearing aortic cusps, valve sparing is often recommended. However, due to the genetic nature of the disease, the durability of such surgery remains uncertain. Between February 2004 and June 2012, 100 patients in our department suffering from aortic aneurysm with aortic valve regurgitation underwent elective aortic valve-sparing surgery. Of them, 30 had Marfan syndrome, were significantly younger (30 +/- 13 vs. 53 +/- 16 years), and had a higher percentage of root aneurysm, compared with ascending aorta aneurysm in their non-Marfan counterparts. We evaluated the safety, durability, clinical and echocardiographic mid-term results of these patients. While no early deaths were reported in either group, there were a few major early complications in both groups. At follow-up (reaching 8 years with a mean of 34 +/- 26 months) there were no late deaths, and few major late complications in the Marfan group. Altogether, 96% and 78% of the patients were in New York Heart Association functional class I-II in the Marfan and non-Marfan groups respectively. None of the Marfan patients needed reoperation on the aortic valve. Freedom from recurrent aortic valve regurgitation > 3+ was 94% in the Marfan patients. Aortic valve-sparing surgery in Marfan symdrome patients is safe and yields good mid-term clinical outcomes.

  7. Valve-sparing aortic root replacement in children: intermediate-term results.

    Science.gov (United States)

    Patel, Nishant D; Arnaoutakis, George J; George, Timothy J; Allen, Jeremiah G; Alejo, Diane E; Dietz, Harry C; Cameron, Duke E; Vricella, Luca A

    2011-03-01

    Valve-sparing root replacement (VSRR) is an attractive option for aortic aneurysm in children with low-operative risk, but mid- and late-term results are not yet known. Between 1997 and 2009, 56 children (mean age 11.5 years) underwent VSRR at our institution. Twenty-six (46.4%) had Marfan syndrome and 24 (42.8%) had Loeys-Dietz syndrome. Mean preoperative max sinus diameter was 4.2±0.8 cm (Z-score 7.7±2.9). Five (8.9%) had >2+ aortic insufficiency (AI). Two (3.6%) underwent David I reimplantation with a straight-tube, 12 (21.4%) had a Yacoub remodeling procedure, and 42 (75.0%) had reimplantation using a Valsalva-graft. There were one (1.8%) operative and three (5.4%) late deaths. One patient required reoperation for bleeding and one required late repair of a distal pseudoaneurysm. Mean follow-up was 5.2 years (range 0-12 years). No patients suffered thromboembolic events or had endocarditis. Of the 12 remodeling patients, four (33.3%) developed >2+ AI and required aortic valve repair or replacement. No patient developed >2+ AI after reimplantation. VSRR in children is a safe alternative to aortic root replacement with mechanical or biological prostheses. In this particular group of patients with connective tissue disorders and proclivity toward annular dilation and late AI, reimplantation is superior to remodeling.

  8. Transcatheter embolization of pseudoaneurysms complicating acute severe pancreatitis

    International Nuclear Information System (INIS)

    Wu Hanping; Liang Huimin; Zheng Chuansheng; Feng Gansheng

    2005-01-01

    Objective: To evaluate the therapeutic roles of transcatheter embolization in patients with pseudoaneurysms complicating acute severe pancreatitis. Methods: Seven patients who suffered from pseudoaneurysms complicating acute severe pancreatitis received abdominal angiography and were treated with transcatheter embolization. The angiographic findings, complications related to the procedure and post- embolization, and rebleeding were observed. Results: The pseudoaneurysms developed at the splenic artery (n=5), right gastroepiploic artery (n=1), and left gastric artery (n=1), respectively. Findings of active bleeding were observed in 3 patients. Six of them were embolized with coils, and the bleedings were stopped immediately. Rebleeding occurred 14-60 days after the embolization in 3 patients, and in one of them, another pseudo aneurysm was observed in repeated angiography and was successfully treated by repeated embolization. No causes of bleeding were found in repeated angiography in the other 2 patients, who died from severe hemorrhage. One pseudo aneurysm was embolized with gelfoam granule. The gastrointestinal bleeding was not controlled and the patient died 3 days later. Procedure related complications occurred in 2 patients. One was celiac trunk rupture during angiography, the other was intima dissecting in splenic artery. Severe post procedure complications occurred in none of the patients. Conclusion: Transcatheter embolization is safe and relatively effective in the management of pseudoaneurysms complicating acute severe pancreatitis. (authors)

  9. Progressive Supranuclear Palsy-like Syndrome After Aortic Aneurysm Repair: A Case Series

    Directory of Open Access Journals (Sweden)

    Sirisha Nandipati

    2013-12-01

    Full Text Available The syndrome of progressive supranuclear palsy‐like syndrome is a rare complication of ascending aortic aneurysm repair. We report two patients with videos and present a table of prior reported cases. To our knowledge there is no previously published video of this syndrome. The suspected mechanism is brainstem injury though neuroimaging is often negative for an associated infarct. We hope our report will increase recognition of this syndrome after aortic surgery, especially in patients with visual complaints.

  10. Prognostic Implications of Raphe in Bicuspid Aortic Valve Anatomy.

    Science.gov (United States)

    Kong, William K F; Delgado, Victoria; Poh, Kian Keong; Regeer, Madelien V; Ng, Arnold C T; McCormack, Louise; Yeo, Tiong Cheng; Shanks, Miriam; Parent, Sarah; Enache, Roxana; Popescu, Bogdan A; Liang, Michael; Yip, James W; Ma, Lawrence C W; Kamperidis, Vasileios; van Rosendael, Philippe J; van der Velde, Enno T; Ajmone Marsan, Nina; Bax, Jeroen J

    2017-03-01

    Little is known about the association between bicuspid aortic valve (BAV) morphologic findings and the degree of valvular dysfunction, presence of aortopathy, and complications, including aortic valve surgery, aortic dissection, and all-cause mortality. To investigate the association between BAV morphologic findings (raphe vs nonraphe) and the degree of valve dysfunction, presence of aortopathy, and prognosis (including need for aortic valve surgery, aortic dissection, and all-cause mortality). In this large international multicenter registry of patients with BAV treated at tertiary referral centers, 2118 patients with BAV were evaluated. Patients referred for echocardiography from June 1, 1991, through November 31, 2015, were included in the study. Clinical and echocardiographic data were analyzed retrospectively. The morphologic BAV findings were categorized according to the Sievers and Schmidtke classification. Aortic valve function was divided into normal, regurgitation, or stenosis. Patterns of BAV aortopathy included the following: type 1, dilation of the ascending aorta and aortic root; type 2, isolated dilation of the ascending aorta; and type 3, isolated dilation of the sinus of Valsalva and/or sinotubular junction. Association between the presence and location of raphe and the risk of significant (moderate and severe) aortic valve dysfunction and aortic dilation and/or dissection. Of the 2118 patients (mean [SD] age, 47 [18] years; 1525 [72.0%] male), 1881 (88.8%) had BAV with fusion raphe, whereas 237 (11.2%) had BAV without raphe. Bicuspid aortic valves with raphe had a significantly higher prevalence of valve dysfunction, with a significantly higher frequency of aortic regurgitation (622 [33.1%] vs 57 [24.1%], P < .001) and aortic stenosis (728 [38.7%] vs 51 [21.5%], P < .001). Furthermore, aortic valve replacement event rates were significantly higher among patients with BAV with raphe (364 [19.9%] at 1 year, 393 [21.4%] at 2 years, and 447

  11. Long-term results of aortic valve replacement with Edwards Prima Plus stentless bioprosthesis: eleven years' follow up.

    Science.gov (United States)

    Auriemma, Stefano; D'Onofrio, Augusto; Brunelli, Massimo; Magagna, Paolo; Paccanaro, Mariemma; Rulfo, Fanny; Fabbri, Alessandro

    2006-09-01

    The Edwards Lifesciences Prima Plus stentless valve (ELSV) is a bioprosthesis manufactured from a porcine aortic root. The study aim was to evaluate late clinical outcomes after aortic valve replacement (AVR) with ELSV implanted as a miniroot in patients with aortic valve disease. Between 1993 and 2004, 318 patients (232 males, 86 females; mean age 69 +/- 9 years; range: 37-83 years) underwent AVR with the ELSV. Preoperatively, 102 patients (32%), 162 (51%) and 54 (17%) were in NYHA classes I/II, III and IV, respectively. Aortic stenosis, aortic regurgitation and combined lesions were present in 124 patients (39%), 114 (36%) and 41 (13%), respectively. Twenty patients (6%) were referred for an acute aortic dissection, 20 (6%) for an aortic root aneurysm, and 139 (44%) had an associated aneurysmal dilatation of the ascending aorta. The ascending aorta was replaced in 159 patients (50%); aortic arch replacement was required in 10 (3%). Coronary artery bypass graft was performed in 86 patients (27%). The follow up was based on clinical data. Operative mortality was 5% (n = 17). There were 49 late deaths (5.2%/pt-yr). Valve-related mortality occurred in 10 patients (1%/pt-yr). Actuarial survival at five and 10 years was 78% and 33%, respectively. Actuarial freedom from valve reoperation and structural valve deterioration at 10 years were 100% and 64%. Actuarial freedom from embolic events and endocarditis at 10 years were 84% and 81%, respectively. The ELSV, when implanted as a miniroot, provided good early and long-term results in terms of survival and freedom from major complications.

  12. Liver Abscess Associated with Hepatic Artery Pseudoaneurysm with Arteriovenous Fistula: Imaging and Interventional Management

    International Nuclear Information System (INIS)

    Kang, M.; Bapuraj, J.R.; Khandelwal, N.; Kochhar, R.; Kalra, N.; Verma, G. R.

    2006-01-01

    Hepatic artery pseudoaneurysm is an infrequently encountered entity that is usually seen secondary to trauma or surgical procedures. The clinical presentation is often due to complications such as massive intrahepatic or intraperitoneal bleeding as a result of rupture of the pseudoaneurysm into the biliary tree or peritoneal cavity, respectively. Hepatic artery pseudoaneurysm, associated with a liver abscess, has very rarely been described in the literature. We present the imaging features of a case of liver abscess associated with a hepatic artery pseudoaneurysm and complicated by rupture and formation of an arteriovenous fistula. The case was successfully managed by percutaneous endovascular embolization. The association between a hepatic artery pseudoaneurysm and a liver abscess must not be overlooked, bearing in mind the potentially fatal associated complications which can be averted or treated by timely intervention

  13. Liver Abscess Associated with Hepatic Artery Pseudoaneurysm with Arteriovenous Fistula: Imaging and Interventional Management

    Energy Technology Data Exchange (ETDEWEB)

    Kang, M.; Bapuraj, J.R.; Khandelwal, N.; Kochhar, R.; Kalra, N.; Verma, G. R. [Postgraduate Inst. of Medical Education and Research, Chandigarh (India). Depts. of Radiodiagnosis and General Surgery

    2006-03-15

    Hepatic artery pseudoaneurysm is an infrequently encountered entity that is usually seen secondary to trauma or surgical procedures. The clinical presentation is often due to complications such as massive intrahepatic or intraperitoneal bleeding as a result of rupture of the pseudoaneurysm into the biliary tree or peritoneal cavity, respectively. Hepatic artery pseudoaneurysm, associated with a liver abscess, has very rarely been described in the literature. We present the imaging features of a case of liver abscess associated with a hepatic artery pseudoaneurysm and complicated by rupture and formation of an arteriovenous fistula. The case was successfully managed by percutaneous endovascular embolization. The association between a hepatic artery pseudoaneurysm and a liver abscess must not be overlooked, bearing in mind the potentially fatal associated complications which can be averted or treated by timely intervention.

  14. Bio-chemo-mechanics of thoracic aortic aneurysms.

    Science.gov (United States)

    Wagenseil, Jessica E

    2018-03-01

    Most thoracic aortic aneurysms (TAAs) occur in the ascending aorta. This review focuses on the unique bio-chemo-mechanical environment that makes the ascending aorta susceptible to TAA. The environment includes solid mechanics, fluid mechanics, cell phenotype, and extracellular matrix composition. Advances in solid mechanics include quantification of biaxial deformation and complex failure behavior of the TAA wall. Advances in fluid mechanics include imaging and modeling of hemodynamics that may lead to TAA formation. For cell phenotype, studies demonstrate changes in cell contractility that may serve to sense mechanical changes and transduce chemical signals. Studies on matrix defects highlight the multi-factorial nature of the disease. We conclude that future work should integrate the effects of bio-chemo-mechanical factors for improved TAA treatment.

  15. Giant cervical internal carotid artery pseudoaneurysm in a child: endovascular treatment

    Energy Technology Data Exchange (ETDEWEB)

    Koeroglu, M.; Arat, A.; Cekirge, S.; Akpinar, E. [Hacettepe University, Department of Radiology, 06100 Ankara (Turkey); Eryilmaz, A.; Akmansu, H. [Ankara Numune Research and Education Hospital, ENT Department, Ankara (Turkey); Koeroglu, Kale B. [Ankara Numune Research and Education Hospital, Internal Medicine Department, Ankara (Turkey)

    2002-10-01

    We report a child with a giant upper cervical internal carotid artery pseudoaneurysm presenting with dysphagia, respiratory distress and a sentinel mild epistaxis, then massive epistaxis. Rupture of the pseudoaneurysm during treatment occurred, as in one reported case. Prompt endovascular treatment yielded a good outcome. (orig.)

  16. Giant cervical internal carotid artery pseudoaneurysm in a child: endovascular treatment

    International Nuclear Information System (INIS)

    Koeroglu, M.; Arat, A.; Cekirge, S.; Akpinar, E.; Eryilmaz, A.; Akmansu, H.; Koeroglu, Kale B.

    2002-01-01

    We report a child with a giant upper cervical internal carotid artery pseudoaneurysm presenting with dysphagia, respiratory distress and a sentinel mild epistaxis, then massive epistaxis. Rupture of the pseudoaneurysm during treatment occurred, as in one reported case. Prompt endovascular treatment yielded a good outcome. (orig.)

  17. Three-dimensional flow structures past a bio-prosthetic valve in an in-vitro model of the aortic root.

    Science.gov (United States)

    Hasler, David; Obrist, Dominik

    2018-01-01

    The flow field past a prosthetic aortic valve comprises many details that indicate whether the prosthesis is functioning well or not. It is, however, not yet fully understood how an optimal flow scenario would look, i.e. which subtleties of the fluid dynamics in place are essential regarding the durability and compatibility of a prosthetic valve. In this study, we measured and analyzed the 3D flow field in the vicinity of a bio-prosthetic heart valve in function of the aortic root size. The measurements were conducted within aortic root phantoms of different size, mounted in a custom-built hydraulic setup, which mimicked physiological flow conditions in the aorta. Tomographic particle image velocimetry was used to measure the 3D instantaneous velocity field at various instances. Several 3D fields (e.g. instantaneous and mean velocity, 3D shear rate) were analyzed and compared focusing on the impact of the aortic root size, but also in order to gain general insight in the 3D flow structure past the bio-prosthetic valve. We found that the diameter of the aortic jet relative to the diameter of the ascending aorta is the most important parameter in determining the characteristics of the flow. A large aortic cross-section, relative to the cross-section of the aortic jet, was associated with higher levels of turbulence intensity and higher retrograde flow in the ascending aorta.

  18. Time-Resolved Three-Dimensional Contrast-Enhanced Magnetic Resonance Angiography in Patients with Chronic Expanding and Stable Aortic Dissections

    Directory of Open Access Journals (Sweden)

    Michael Trojan

    2017-01-01

    Full Text Available Objective. To prospectively evaluate our hypothesis that three-dimensional time-resolved contrast-enhanced magnetic resonance angiography (TR-MRA is able to detect hemodynamic alterations in patients with chronic expanding aortic dissection compared to stable aortic dissections. Materials and Methods. 20 patients with chronic or residual aortic dissection in the descending aorta and patent false lumen underwent TR-MRA of the aorta at 1.5 T and repeated follow-up imaging (mean follow-up 5.4 years. 7 patients showed chronic aortic expansion and 13 patients had stable aortic diameters. Regions of interest were placed in the nondissected ascending aorta and the false lumen of the descending aorta at the level of the diaphragm (FL-diaphragm level resulting in respective time-intensity curves. Results. For the FL-diaphragm level, time-to-peak intensity and full width at half maximum were significantly shorter in the expansion group compared to the stable group (p=0.027 and p=0.003, and upward and downward slopes of time-intensity curves were significantly steeper (p=0.015 and p=0.005. The delay of peak intensity in the FL-diaphragm level compared to the nondissected ascending aorta was significantly shorter in the expansion group compared to the stable group (p=0.01. Conclusions. 3D TR-MRA detects significant alterations of hemodynamics within the patent false lumen of chronic expanding aortic dissections compared to stable aortic dissections.

  19. Aortic Dissection Type A in Alpine Skiers

    Directory of Open Access Journals (Sweden)

    Thomas Schachner

    2013-01-01

    Full Text Available Patients and Methods. 140 patients with aortic dissection type A were admitted for cardiac surgery. Seventy-seven patients experienced their dissection in the winter season (from November to April. We analyzed cases of ascending aortic dissection associated with alpine skiing. Results. In 17 patients we found skiing-related aortic dissections. Skiers were taller (180 (172–200 cm versus 175 (157–191 cm, and heavier (90 (68–125 kg versus 80 (45–110 kg, than nonskiers. An extension of aortic dissection into the aortic arch, the descending thoracic aorta, and the abdominal aorta was found in 91%, 74%, and 69%, respectively, with no significant difference between skiers and nonskiers. Skiers experienced RCA ostium dissection requiring CABG in 17.6% while this was true for 5% of nonskiers (. Hospital mortality of skiers was 6% versus 13% in nonskiers (. The skiers live at an altitude of 170 (0–853 m.a.s.l. and experience their dissection at 1602 (1185–3105; m.a.s.l. In 82% symptom start was during recreational skiing without any trauma. Conclusion. Skiing associated aortic dissection type A is usually nontraumatic. The persons affected live at low altitudes and practice an outdoor sport at unusual high altitude at cold temperatures. Postoperative outcome is good.

  20. Total Endovascular Aortic Repair in a Patient with Marfan Syndrome.

    Science.gov (United States)

    Amako, Mau; Spear, Rafaëlle; Clough, Rachel E; Hertault, Adrien; Azzaoui, Richard; Martin-Gonzalez, Teresa; Sobocinski, Jonathan; Haulon, Stéphan

    2017-02-01

    The aim of this study is to describe a total endovascular aortic repair with branched and fenestrated endografts in a young patient with Marfan syndrome and a chronic aortic dissection. Open surgery is the gold standard to treat aortic dissections in patients with aortic disease and Marfan syndrome. In 2000, a 38-year-old man with Marfan syndrome underwent open ascending aorta repair for an acute type A aortic dissection. One year later, a redo sternotomy was performed for aortic valve replacement. In 2013, the patient presented with endocarditis and pulmonary infection, which necessitated tracheostomy and temporary dialysis. In 2014, the first stage of the endovascular repair was performed using an inner branched endograft to exclude a 77-mm distal arch and descending thoracic aortic aneurysm. In 2015, a 63-mm thoracoabdominal aortic aneurysm was excluded by implantation of a 4-fenestrated endograft. Follow-up after both endovascular repairs was uneventful. Total aortic endovascular repair was successfully performed to treat a patient with arch and thoraco-abdominal aortic aneurysm associated with chronic aortic dissection and Marfan syndrome. The postoperative images confirmed patency of the endograft and its branches, and complete exclusion of the aortic false lumen. Endovascular repair is a treatment option in patients with connective tissue disease who are not candidates for open surgery. Long-term follow-up is required to confirm these favorable early outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Hepatic arterial pseudoaneurysm: a rare complication of blunt abdominal trauma in children

    International Nuclear Information System (INIS)

    Basile, K.E.; Sivit, C.J.; Sachs, P.B.; Stallion, A.

    1999-01-01

    We report a child who developed a hepatic artery pseudoaneurysm following blunt hepatic injury. This is a rare complication of hepatic trauma in children. The imaging evaluation and clinical management of hepatic artery pseudoaneurysms are presented. (orig.)

  2. Selective Aortic Arch and Root Replacement in Repair of Acute Type A Aortic Dissection.

    Science.gov (United States)

    Fleischman, Fernando; Elsayed, Ramsey S; Cohen, Robbin G; Tatum, James M; Kumar, S Ram; Kazerouni, Kayvan; Mack, Wendy J; Barr, Mark L; Cunningham, Mark J; Hackmann, Amy E; Baker, Craig J; Starnes, Vaughn A; Bowdish, Michael E

    2018-02-01

    Controversy exists regarding the optimal extent of repair for type A aortic dissection. Our approach is to replace the ascending aorta, and only replace the aortic root or arch when intimal tears are present in those areas. We examined intermediate outcomes with this approach to acute type A aortic dissection repair. Between March 2005 and October 2016, 195 patients underwent repair of acute type A aortic dissection. Repair was categorized by site of proximal and distal anastomosis and extent of repair. Mean follow-up was 31.0 ± 30.9 months. Kaplan-Meier analysis was used to assess survival. Multiple variable Cox proportional hazards modeling was utilized to identify factors associated with overall mortality. Overall survival was 85.1%, 83.9%, 79.1%, and 74.4% at 6, 12, 36, and 60 months, respectively. Eight patients required reintervention. The cumulative incidence of aortic reintervention at 1 year with death as a competing outcome was 3.95%. Multiple variable regression analysis identified factors such as age, preoperative renal failure, concomitant thoracic endograft, postoperative myocardial infarction and sepsis, and need for extracorporeal membrane oxygenation as predictive of overall mortality. Neither proximal or distal extent of repair, nor need for reintervention affected overall survival (proximal: hazard ratio 1.63, 95% confidence interval: 0.75 to 3.51, p = 0.22; distal: hazard ratio 1.12, 95% confidence interval: 0.43 to 2.97, p = 0.81; reintervention: hazard ratio 0.03, 95% confidence interval: 0.002 to 0.490, p < 0.01). A selective approach to root and arch repair in acute type A aortic dissection is safe. If aortic reintervention is needed, survival does not appear to be affected. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Evaluation of chemokine receptors (CCRs expression on peripheral blood T-lymphocyte subsets in patients with thoracic aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Kaushal Kishore Tiwari

    2016-03-01

    Full Text Available Background & Objectives: Mortality and morbidity from the complication of aortic aneurysm remain very high. Aortic size index, which classify thoracic aortic aneurysm patients in three risk groups for aortic rupture prediction. Recent data support that aortic wall remodeling is a dynamic process with active involvement of the chronic inflammation and immunological system. Aim of our study is to evaluate expression level of chemokine receptors known to be involved in the T-cells migration and to correlate them with aortic size index. Materials & Methods: Total 20 patients undergoing surgery for ascending aortic aneurysm and/or aortic valve surgery were enrolled. Aortic size index was calculated. Preoperatively blood samples collected. By flowcytometry and dual parameter dot plot technology percentage of positivity of CCR5 on these T-cell subsets were quantified. Results: Mean age of the patients was 67±5.93 years. Majority of patients had hypertension. Mean ascending aortic diameter was 42.1±8.14 mm. Mean Aortic size Index was 22.21±3.38 mm/m2. A statistical significance has observed between aortic size index and the expression of CCR5 on total CD4 positive T-cells (p-0.0949, and between aortic size index and CCR5 expression on the total CD3 positive T-cells (p-0.0293. Significant correlation observed between ASI and CCR5 expression on the CD8+/CD3+ T-cell subset (p-0.0183. Similarly, strong positive relationship between ASI and the expression of CCR5 on the cytotoxic CD28-/CD4+ T-cell subset (p-0.0055. Activated state of cytotoxic CD28-/CD4+ cell also correlated with aortic size index (p-0.0668.Conclusion: We conclude that T-cell mediated cytotoxic mechanism driven by CCR5 play an important role in the pathophysiology of the thoracic aortic aneurysm.JCMS Nepal. 2016;12(1:23-27.

  4. Influence of the tilt angle of Percutaneous Aortic Prosthesis on Velocity and Shear Stress Fields

    Directory of Open Access Journals (Sweden)

    Bruno Alvares de Azevedo Gomes

    Full Text Available Abstract Background: Due to the nature of the percutaneous prosthesis deployment process, a variation in its final position is expected. Prosthetic valve placement will define the spatial location of its effective orifice in relation to the aortic annulus. The blood flow pattern in the ascending aorta is related to the aortic remodeling process, and depends on the spatial location of the effective orifice. The hemodynamic effect of small variations in the angle of inclination of the effective orifice has not been studied in detail. Objective: To implement an in vitro simulation to characterize the hydrodynamic blood flow pattern associated with small variations in the effective orifice inclination. Methods: A three-dimensional aortic phantom was constructed, reproducing the anatomy of one patient submitted to percutaneous aortic valve implantation. Flow analysis was performed by use of the Particle Image Velocimetry technique. The flow pattern in the ascending aorta was characterized for six flow rate levels. In addition, six angles of inclination of the effective orifice were assessed. Results: The effective orifice at the -4° and -2° angles directed the main flow towards the anterior wall of the aortic model, inducing asymmetric and high shear stress in that region. However, the effective orifice at the +3° and +5° angles mimics the physiological pattern, centralizing the main flow and promoting a symmetric distribution of shear stress. Conclusion: The measurements performed suggest that small changes in the angle of inclination of the percutaneous prosthesis aid in the generation of a physiological hemodynamic pattern, and can contribute to reduce aortic remodeling.

  5. Aortic root dimensions are predominantly determined by genetic factors: a classical twin study

    International Nuclear Information System (INIS)

    Celeng, Csilla; Kolossvary, Marton; Kovacs, Attila; Molnar, Andrea Agnes; Szilveszter, Balint; Karolyi, Mihaly; Jermendy, Adam L.; Karady, Julia; Merkely, Bela; Maurovich-Horvat, Pal; Horvath, Tamas; Tarnoki, Adam D.; Tarnoki, David L.; Voros, Szilard; Jermendy, Gyoergy

    2017-01-01

    Previous studies using transthoracic echocardiography (TTE) observed moderate heritability of aortic root dimensions. Computed tomography angiography (CTA) might provide more accurate heritability estimates. Our primary aim was to assess the heritability of the aortic root with CTA. Our secondary aim was to derive TTE-based heritability and compare this with the CTA-based results. In the BUDAPEST-GLOBAL study 198 twin subjects (118 monozygotic, 80 dizygotic; age 56.1 ± 9.4 years; 126 female) underwent CTA and TTE. We assessed the diameter of the left ventricular outflow tract (LVOT), annulus, sinus of Valsalva, sinotubular junction and ascending aorta. Heritability was assessed using ACDE model (A additive genetic, C common environmental, D dominant genetic, E unique environmental factors). Based on CTA, additive genetic effects were dominant (LVOT: A = 0.67, E = 0.33; annulus: A = 0.76, E = 0.24; sinus of Valsalva: A = 0.83, E = 0.17; sinotubular junction: A = 0.82, E = 0.18; ascending aorta: A = 0.75, E = 0.25). TTE-derived measurements showed moderate to no genetic influence (LVOT: A = 0.38, E = 0.62; annulus: C = 0.47, E = 0.53; sinus of Valsalva: C = 0.63, E = 0.37; sinotubular junction: C = 0.45, E = 0.55; ascending aorta: A = 0.67, E = 0.33). CTA-based assessment suggests that aortic root dimensions are predominantly determined by genetic factors. TTE-based measurements showed moderate to no genetic influence. The choice of measurement method has substantial impact on heritability estimates. (orig.)

  6. Aortic root dimensions are predominantly determined by genetic factors: a classical twin study

    Energy Technology Data Exchange (ETDEWEB)

    Celeng, Csilla; Kolossvary, Marton; Kovacs, Attila; Molnar, Andrea Agnes; Szilveszter, Balint; Karolyi, Mihaly; Jermendy, Adam L.; Karady, Julia; Merkely, Bela; Maurovich-Horvat, Pal [Semmelweis University, MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Budapest (Hungary); Horvath, Tamas [Budapest University of Technology and Economics, Department of Hydrodynamic Systems, Budapest (Hungary); Tarnoki, Adam D.; Tarnoki, David L. [Semmelweis University, Department of Radiology and Oncotherapy, Budapest (Hungary); Voros, Szilard [Global Genomics Group, Atlanta, GA (United States); Jermendy, Gyoergy [Bajcsy-Zsilinszky Hospital, Medical Department, Budapest (Hungary)

    2017-06-15

    Previous studies using transthoracic echocardiography (TTE) observed moderate heritability of aortic root dimensions. Computed tomography angiography (CTA) might provide more accurate heritability estimates. Our primary aim was to assess the heritability of the aortic root with CTA. Our secondary aim was to derive TTE-based heritability and compare this with the CTA-based results. In the BUDAPEST-GLOBAL study 198 twin subjects (118 monozygotic, 80 dizygotic; age 56.1 ± 9.4 years; 126 female) underwent CTA and TTE. We assessed the diameter of the left ventricular outflow tract (LVOT), annulus, sinus of Valsalva, sinotubular junction and ascending aorta. Heritability was assessed using ACDE model (A additive genetic, C common environmental, D dominant genetic, E unique environmental factors). Based on CTA, additive genetic effects were dominant (LVOT: A = 0.67, E = 0.33; annulus: A = 0.76, E = 0.24; sinus of Valsalva: A = 0.83, E = 0.17; sinotubular junction: A = 0.82, E = 0.18; ascending aorta: A = 0.75, E = 0.25). TTE-derived measurements showed moderate to no genetic influence (LVOT: A = 0.38, E = 0.62; annulus: C = 0.47, E = 0.53; sinus of Valsalva: C = 0.63, E = 0.37; sinotubular junction: C = 0.45, E = 0.55; ascending aorta: A = 0.67, E = 0.33). CTA-based assessment suggests that aortic root dimensions are predominantly determined by genetic factors. TTE-based measurements showed moderate to no genetic influence. The choice of measurement method has substantial impact on heritability estimates. (orig.)

  7. Analysis of Systolic Backflow and Secondary Helical Blood Flow in the Ascending Aorta Using Vector Flow Imaging

    DEFF Research Database (Denmark)

    Hansen, Kristoffer Lindskov; Møller-Sørensen, Hasse; Kjaergaard, Jesper

    2016-01-01

    echocardiography and pulmonary artery catheter thermodilution, and associated with gender, age, aortic diameter, atherosclerotic plaques, left ventricular ejection fraction and previous myocardial infarctions. Secondary flow was present for all patients. The duration and rotational frequency (p ... that backflow is injurious and that secondary flow is a normal flow phenomenon. The study also shows that transverse oscillation can provide new information on blood flow in the ascending aorta....

  8. Pseudoaneurysm of the Common Carotid Artery in an Infant due to Swallowed Fish Bone

    Directory of Open Access Journals (Sweden)

    Moulion Tapouh Jean Roger

    2015-01-01

    Full Text Available Carotid artery pseudoaneurysm is a rare condition, particularly in the paediatric population. Only about 30 cases of carotid artery aneurysms in infants have been published until now. This paper reports the case of a giant pseudoaneurysm of the left common carotid artery due to swallowed fish bone by an 8-year-old boy. This pseudoaneurysm was 5.5 cm transverse-diameter and resulted in severe respiratory distress. It was treated by resection and end-to-end anastomosis with satisfactory outcome after one-year follow-up. To the best of our knowledge, this is the largest carotid artery pseudoaneurysm ever described in children.

  9. Two Cases of Postmyomectomy Pseudoaneurysm Treated by Transarterial Embolization

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Nobutake, E-mail: nobutake@rad.med.keio.ac.jp [Keio University, School of Medicine, Department of Diagnostic Radiology (Japan); Natimatsu, Yoshiaki; Tsukada, Jitsuro; Sato, Akihiro; Hasegawa, Ichiro [Kawasaki Municipal Hospital, Department of Diagnostic Radiology (Japan); Lin, Bao-Liang [Kawasaki Municipal Hospital, Department of Gynecologic Endoscopy (Japan)

    2013-12-15

    Pseudoaneurysm resulting from hysteroscopic myomectomy is a rare clinical situation, and interventional radiologists are not traditionally involved in the management. To our knowledge, endovascular treatment of a pseudoaneurysm resulting from hysteroscopic myomectomy has not yet been reported in the English-language literature. Here, two such cases are reported, including one of a woman who later became pregnant. The case is unique because little is known about the influence of unilateral coil embolization of the uterine artery on fertility.

  10. Two Cases of Postmyomectomy Pseudoaneurysm Treated by Transarterial Embolization

    International Nuclear Information System (INIS)

    Ito, Nobutake; Natimatsu, Yoshiaki; Tsukada, Jitsuro; Sato, Akihiro; Hasegawa, Ichiro; Lin, Bao-Liang

    2013-01-01

    Pseudoaneurysm resulting from hysteroscopic myomectomy is a rare clinical situation, and interventional radiologists are not traditionally involved in the management. To our knowledge, endovascular treatment of a pseudoaneurysm resulting from hysteroscopic myomectomy has not yet been reported in the English-language literature. Here, two such cases are reported, including one of a woman who later became pregnant. The case is unique because little is known about the influence of unilateral coil embolization of the uterine artery on fertility

  11. Hepatic arterial pseudoaneurysm: a rare complication of blunt abdominal trauma in children

    Energy Technology Data Exchange (ETDEWEB)

    Basile, K.E.; Sivit, C.J.; Sachs, P.B. [Department of Radiology, Rainbow Babies and Children`s Hospital of the University Hospitals of Cleveland, OH (United States); Stallion, A. [Department of Surgery, Rainbow Babies` and Children`s Hospital of the University Hospitals of Cleveland, OH (United States)

    1999-05-01

    We report a child who developed a hepatic artery pseudoaneurysm following blunt hepatic injury. This is a rare complication of hepatic trauma in children. The imaging evaluation and clinical management of hepatic artery pseudoaneurysms are presented. (orig.) With 3 figs., 8 refs.

  12. Traumatic intracranial internal carotid artery pseudoaneurysm presenting as epistaxis treated by endovascular coiling

    Science.gov (United States)

    Al-Jehani, Hosam M.; Alwadaani, Hassan A.; Almolani, Fadhel M.

    2016-01-01

    Traumatic intracranial pseudoaneurysm is a rare complication of blunt trauma. It is even more rare when it presents as epistaxis. Massive epistaxis of a ruptured intracranial internal carotid artery pseudoaneurysm is a major cause of mortality, which requires emergency intervention. We report a case of traumatic intracranial internal carotid artery pseudoaneurysm secondary to skull base fracture, which presented with delayed onset of epistaxis. This was successfully treated by primary endovascular coil embolization. We discuss endovascular treatment options and review the literature. PMID:26818170

  13. Percutaneous treatment of femoral pseudoaneurysms: comparison of fibrin sealant against thrombin

    Directory of Open Access Journals (Sweden)

    Daniel Mendes Pinto

    2013-12-01

    Full Text Available INTRODUCTION: Femoral pseudoaneurysms are a complication that occurs in connection with up to 8% of percutaneous procedures. Of the available treatments, ultrasound guided thrombin injection has a high success rate and is well-tolerated by patients. The combination of thrombin and fibrinogen known as fibrin sealant forms a stable clot and can be used to treat pseudoaneurysms, particularly those with complex anatomy and larger size. OBJECTIVE: To compare the results of treating femoral pseudoaneurysm in two ways: Group T was treated with thrombin alone and Group T+F was treated with fibrin sealant (thrombin+fibrinogen. METHODS: A retrospective analysis was conducted of femoral pseudoaneurysm cases treated between January 2005 and December 2012. RESULTS: Twenty-eight patients were treated, 21 with thrombin alone and seven with fibrin sealant. All patients in group T were treated successfully, but only four patients in group T+F were treated successfully (57.1% success rate in Group T+F, p<0.01. The three cases of failure in group T+F needed surgery and in one of these cases the complication was embolization to the femoral bifurcation. The pseudoaneurysms that were treated with fibrin sealant were larger (25 cm3 in Group T and 57.7 cm3 in Group T+F, p=0.02 and required larger volumes of thrombin (0.5 mL in Group T and 1.0 mL in Group T+F, p<0.01. There was one complication in Group T and two complications in Group T+F (p<0.01. CONCLUSIONS: Irrespective of the small number of cases reviewed, treatment with thrombin alone was superior to treating with fibrin sealant, since it caused few complications and was more effective at correcting pseudoaneurysms.

  14. Hyperattenuating aortic wall on postmortem computed tomography (PMCT)

    Energy Technology Data Exchange (ETDEWEB)

    Shiotani, Seiji; Kohno, Mototsugu; Ohashi, Noriyoshi; Yamazaki, Kentaroh; Nakayama, Hidetsugu; Ito, Yoshiyuki; Kaga, Kazunori; Ebashi, Toshio [Tsukuba Medical Center Hospital, Ibaraki (Japan); Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    2002-08-01

    The purpose of this study was to quantitatively evaluate the finding of hyperattenuating aortic wall on postmortem computed tomography (PMCT) and investigate its causes. Our subjects were 50 PMCT of non-traumatic deaths and 50 CT of living persons (live CT). The ascending aorta at the level of the carina was visually assessed regarding the presence or absence of hyperattenuating aortic wall and hematocrit effect on PMCT and live CT. The diameter, thickness of the aortic wall, and CT number (HU) of the aortic wall and the lumen were also measured. Hyperattenuating aortic wall was detected in 100% of PMCT and 2% of live CT. The diameter of the aortic wall was 2.9{+-}0.5 cm on PMCT and 3.5{+-}0.5 cm on live CT, showing a significant difference. The thickness of the aortic wall was 2 mm on PMCT. Hematocrit effect was observed in 46% of PMCT and in none of live CT. With PMCT, there was a significant difference between the CT numbers of the upper and lower half portions of the lumen (19.6{+-}11.7/30.9{+-}12.9), whereas, with live CT, there was no such significant difference (37.4{+-}7.6/38.9{+-}6.7), with the overall value of 38.2{+-}6.7. The CT number of the aortic wall was 49.9{+-}10.9 on PMCT. The causes of hyperattenuating aortic wall on PMCT are considered to be increased attenuation due to contraction of the aortic wall, a lack of motion artifact, and decreased attenuation of the lumen due to dilution of blood after massive infusion at the time of cardiopulmonary resuscitation. (author)

  15. Characteristics of Pseudoaneurysms in Northern India; Risk Analysis, Clinical Profile, Surgical Management and Outcome.

    Science.gov (United States)

    Lone, Hafeezulla; Ganaie, Farooq Ahmad; Lone, Ghulam Nabi; Dar, Abdul Majeed; Bhat, Mohammad Akbar; Singh, Shyam; Parra, Khursheed Ahmad

    2015-04-01

    To determine the risk factors, clinical characteristics, surgical management and outcome of pseudoaneurysm secondary to iatrogenic or traumatic vascular injury. This was a cross-sectional study being performed in department of cardiovascular and thoracic surgery skims soura during a 4-year period. We included all the patients referring to our center with primary diagnosis of pseudoaneurysm. The pseudoaneurysm was diagnosed with angiography and color Doppler sonography. The clinical and demographic characteristics were recorded and the risk factors were identified accordingly. Patients with small swelling (less than 5-cm) and without any complication were managed conservatively. They were followed for progression and development of complications in relation to swelling. Others underwent surgical repair and excision. The outcome of the patients was also recorded. Overall we included 20 patients with pseudoaneurysm. The mean age of the patients was 42.1±0.6 years. Among them there were 11 (55%) men and 9 (45%) women. Nine (45%) patients with end stage renal disease developed pseudoaneurysm after inadvertent femoral artery puncture for hemodialysis; two patients after interventional cardiology procedure; one after femoral embolectomy; one developed after fire arm splinter injury and one formed femoral artery related pseudoaneurysm after drainage of right inguinal abscess. The most common site of pseudoaneurysm was femoral artery followed by brachial artery. Overall surgical intervention was performed in 17 (85%) patients and 3 (15%) were managed conservatively. End stage renal disease is a major risk factor for pseudoaneurysm formation. Coagulopathy, either therapeutic or pathological is also an important risk factor. Patients with these risk factors need cannulation of venous structures for hemodialysis under ultrasound guide to prevent inadvertent arterial injury. Patients with end stage renal disease who sustain inadvertent arterial puncture during cannulation for

  16. Three-dimensional thoracic aorta principal strain analysis from routine ECG-gated computerized tomography: feasibility in patients undergoing transcatheter aortic valve replacement.

    Science.gov (United States)

    Satriano, Alessandro; Guenther, Zachary; White, James A; Merchant, Naeem; Di Martino, Elena S; Al-Qoofi, Faisal; Lydell, Carmen P; Fine, Nowell M

    2018-05-02

    Functional impairment of the aorta is a recognized complication of aortic and aortic valve disease. Aortic strain measurement provides effective quantification of mechanical aortic function, and 3-dimenional (3D) approaches may be desirable for serial evaluation. Computerized tomographic angiography (CTA) is routinely performed for various clinical indications, and offers the unique potential to study 3D aortic deformation. We sought to investigate the feasibility of performing 3D aortic strain analysis in a candidate population of patients undergoing transcatheter aortic valve replacement (TAVR). Twenty-one patients with severe aortic valve stenosis (AS) referred for TAVR underwent ECG-gated CTA and echocardiography. CTA images were analyzed using a 3D feature-tracking based technique to construct a dynamic aortic mesh model to perform peak principal strain amplitude (PPSA) analysis. Segmental strain values were correlated against clinical, hemodynamic and echocardiographic variables. Reproducibility analysis was performed. The mean patient age was 81±6 years. Mean left ventricular ejection fraction was 52±14%, aortic valve area (AVA) 0.6±0.3 cm 2 and mean AS pressure gradient (MG) 44±11 mmHg. CTA-based 3D PPSA analysis was feasible in all subjects. Mean PPSA values for the global thoracic aorta, ascending aorta, aortic arch and descending aorta segments were 6.5±3.0, 10.2±6.0, 6.1±2.9 and 3.3±1.7%, respectively. 3D PSSA values demonstrated significantly more impairment with measures of worsening AS severity, including AVA and MG for the global thoracic aorta and ascending segment (panalysis is clinically feasible from routine ECG-gated CTA. Appropriate reductions in PSSA were identified with increasing AS hemodynamic severity. Expanded study of 3D aortic PSSA for patients with various forms of aortic disease is warranted.

  17. Pseudoaneurysm of the Radial Artery After a Bicycle Fall.

    Science.gov (United States)

    Ratschiller, Thomas; Müller, Hannes; Schachner, Thomas; Zierer, Andreas

    2018-07-01

    We report a case of a 64-year-old man who developed a painful pulsatile mass in the distal forearm after a bicycle fall with fracture of the wrist. Ultrasonography confirmed a 2.5-cm large pseudoaneurysm of the radial artery. The patient underwent surgical exploration. The pseudoaneurysm was resected and the defect in the arterial wall was reconstructed with an autologous saphenous vein patch. We suggest that the double arterial supply of the hand should be preserved whenever possible.

  18. Idiopathic Splenic Artery Pseudoaneurysm Rupture as an Uncommon Cause of Hemorrhagic Shock

    Directory of Open Access Journals (Sweden)

    Richard A. Schatz MD

    2015-04-01

    Full Text Available Splenic artery pseudoaneurysms are infrequently encountered but critical to recognize. Limited literature to date describes associations with pancreatitis, trauma, and rarely peptic ulcer disease. Hemorrhage and abdominal pain are the most common manifestations. There is typically overt gastrointestinal blood loss but bleeding can also extend into the peritoneum, retroperitoneum, adjacent organs, or even a pseudocyst. Most patients with ruptured splenic artery pseudoaneurysms present with hemodynamic instability. Here, we describe a patient recovering from acute illness in the intensive care unit but with otherwise no obvious risk factors or precipitants for visceral pseudoaneurysm. He presented with acute onset altered mental status, nausea, and worsening back and abdominal pain and was found to be in hypovolemic shock. The patient was urgently stabilized until more detailed imaging could be performed, which ultimately revealed the source of blood loss and explained his rapid decompensation. He was successfully treated with arterial coiling and embolization. Thus, we herein emphasize the importance of prompt recognition of hemorrhagic shock and of aggressive hemodynamic stabilization, as well as a focused diagnostic approach to this problem with specific treatment for splenic artery pseudoaneurysm. Finally, we recommend that multidisciplinary management should be the standard approach in all patients with splenic artery pseudoaneurysm.

  19. Significance of transcatheter arterial embolization in the treatment of pseudoaneurysm complicating pancreatitis

    International Nuclear Information System (INIS)

    Kim, Sang Gyee; Joo, Jung Hyun; Kim, Young Cheol; Kim, Jae Kyu; Jeong, Yong Yeon; Kang, Heoung Keun; Oh, Hee Yeon

    1998-01-01

    To evaluate the significance of transcatheter arterial embolization(TAE) of pseudoaneurysm complicating pancreatitis. This study was based on a retrospective analysis of eight cases, in which TAE for control of pseudoaneurysm complicating pancreatitis was attempted. All patients were males, and were aged between 35 and 65(mean, 47) years. Seven had a history of episodes of chronic pancreatitis and one case was the result of acute pancreatitis. All patients underwent diagnostic angiography and superselective embolization. Arteries in which pseudoaneurysm had occurred were the gastroduodenal (n=3D5), inferior pancreaticoduodenal (n=3D1), superior mesenteric artery root (n=3D1), and the celiac axis (n=3D1). Six cases were treated successfully without complications, but in two, embolization failed due to a wide aneurysmal neck arising from the superior mesenteric artery root and celiac axis. In four successful cases, pseudoaneurysms were completely resolved within three to six months of embolization. One of the other two remained as a pseudocyst, while in the other, also a pseudocyst, surgery was performed. Because TAE in patients with pseudoaneurysm complicating pancreatitis has a high success rate, and also leads to absolute resorption of a pseudocyst, TAE is the preferred pre-surgical treatment mode.=20

  20. Significance of transcatheter arterial embolization in the treatment of pseudoaneurysm complicating pancreatitis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Gyee; Joo, Jung Hyun; Kim, Young Cheol; Kim, Jae Kyu; Jeong, Yong Yeon; Kang, Heoung Keun [Chonnam Univ. School of Medicine, Kwangju (Korea, Republic of); Oh, Hee Yeon [Namkwang Hospital, Kwangju (Korea, Republic of)

    1998-11-01

    To evaluate the significance of transcatheter arterial embolization(TAE) of pseudoaneurysm complicating pancreatitis. This study was based on a retrospective analysis of eight cases, in which TAE for control of pseudoaneurysm complicating pancreatitis was attempted. All patients were males, and were aged between 35 and 65(mean, 47) years. Seven had a history of episodes of chronic pancreatitis and one case was the result of acute pancreatitis. All patients underwent diagnostic angiography and superselective embolization. Arteries in which pseudoaneurysm had occurred were the gastroduodenal (n=3D5), inferior pancreaticoduodenal (n=3D1), superior mesenteric artery root (n=3D1), and the celiac axis (n=3D1). Six cases were treated successfully without complications, but in two, embolization failed due to a wide aneurysmal neck arising from the superior mesenteric artery root and celiac axis. In four successful cases, pseudoaneurysms were completely resolved within three to six months of embolization. One of the other two remained as a pseudocyst, while in the other, also a pseudocyst, surgery was performed. Because TAE in patients with pseudoaneurysm complicating pancreatitis has a high success rate, and also leads to absolute resorption of a pseudocyst, TAE is the preferred pre-surgical treatment mode.=20.

  1. Successful Percutaneous Coronary Intervention through a Severely Bent Artificial Ascending Aorta Using the DIO Thrombus Aspiration Catheter

    Directory of Open Access Journals (Sweden)

    Akinori Fujikake

    2016-01-01

    Full Text Available A 66-year-old man was admitted to our institute because of chest pain. He had undergone replacement of the ascending aorta due to aortic dissection 9 years previously. We made a diagnosis of acute coronary syndrome, and coronary artery angiography was performed. Although the right coronary artery was successfully cannulated, a severe bend of the artificial aorta made it very difficult to advance the catheter into the left coronary artery. Ultimately, a DIO thrombus aspiration catheter was used to enter the left coronary artery, and a stent was implanted successfully. The DIO catheter is very useful when the selection of a guiding catheter is complicated, such as in the case of severe vessel tortuosity or a bend of the ascending aorta.

  2. Endovascular Treatment of a Vertebral Artery Pseudoaneurysm in a Drug User

    International Nuclear Information System (INIS)

    Mourikis, Dimitrios; Chatziioannou, Achilleas; Doriforou, Ortansia; Skiadas, Vasilios; Koutoulidis, Vasilios; Katsenis, Konstantinos; Vlahos, Lampros

    2006-01-01

    A 26-year-old drug abuser who presented with sepsis was found to have a pseudoaneurysm in the left vertebral artery. This aneurysm was presumed to be post-traumatic, since the patient reported multiple attempts to inject drugs in the left jugular vein 15 days prior to admission. The pseudoaneurysm was treated effectively with stent-graft placement

  3. Multiple small pseudoaneurysms complicating pancreatitis: angiographic diagnosis and transcatheter embolization

    International Nuclear Information System (INIS)

    Maleux, G.; Stockx, L.; Vanbeckevoort, D.; Wilms, G.; Marchal, G.; Steenbergen, W. van

    2000-01-01

    We report a case of retroperitoneal hemorrhage due to multiple, small pseudoaneurysms complicating a chronic alcoholic pancreatitis. Cross-sectional imaging with CT and US could not clearly depict these vascular lesions. Selective arteriography of the superior mesenteric and gastroduodenal arteries clearly showed the small pseudoaneurysms and definitive treatment was performed by transcatheter embolization using coils. Eight months after successful embolization, the patient is asymptomatic without any recurrent bleeding. (orig.)

  4. Aortoplastia redutora com contenção externa associada à troca valvar aórtica em pacientes de alto risco Reduction aortoplasty with external wrapping associated with aortic valve replacement in high-risk patients

    Directory of Open Access Journals (Sweden)

    Rafael Haddad

    2009-06-01

    Full Text Available OBJETIVO: Avaliar a evolução de pacientes de alto risco submetidos a aortoplastia redutora com contenção externa associada a troca valvar aórtica. MÉTODOS: Seis pacientes portadores de aneurisma de aorta ascendente e valvopatia aórtica, sendo quatro do sexo masculino, foram incluídos no estudo. Um paciente apresentava insuficiência mitral importante. A idade variou de 61 a 70 anos (média de 65,7 anos. A insuficiência aórtica foi a indicação de troca valvar em 83,3% dos pacientes e a estenose aórtica, em 16,7%. Os critérios de inclusão foram: pacientes portadores de valvopatia aórtica com indicação cirúrgica, aorta ascendente com diâmetro > 5,5 cm, EuroSCORE > 6 e idade acima de 60 anos. O diâmetro da aorta ascendente variou de 57 a 68 mm (média de 63,7 mm. Análise estatística foi realizada utilizando o teste t pareado para as variáveis estudadas, com nível de significância menor que 5%. RESULTADOS: Todos os pacientes foram submetidos a aortoplastia redutora com contenção externa associada a troca valvar aórtica. Não houve mortalidade hospitalar na série estudada. Um (16,7% paciente apresentou fibrilação atrial no pós-operatório. O diâmetro médio da aorta ascendente foi de 37,0 +4,5 mm aos 6 meses de pós-operatório (P OBJECTIVE: To assess the midterm follow-up of reduction aortoplasty with external wrapping associated with aortic valve replacement in high risk patients. METHODS: Six patients with ascending aortic aneurysm and aortic valve disease were included in this study. Four of them were male. The age ranged from 61 to 70 years (mean 65.7 years. One patient presented severe mitral valve insufficiency. All patients underwent aortic valve replacement (83.3% with aortic insufficiency and 16.7% with aortic stenosis. The inclusion criteria were: surgical aortic valve disease, ascending aortic aneurysm > 5.5 cm, EuroSCORE > 6 and age above 60 years. The ascending aortic diameter ranged from 57 to 68 mm

  5. Interventional radiology in the management of visceral artery pseudoaneurysms: A review of techniques and embolic materials

    Energy Technology Data Exchange (ETDEWEB)

    Madhusudhan, Kumble Seetharama; Venkatesh, Hosur Ananthashayana; Gamanagatti, Shivanand; Garg, Pramod; Srivastava, Deep Narayan [All India Institute of Medical Sciences, New Delhi (India)

    2016-06-15

    Visceral artery pseudoaneurysms occur mostly as a result of inflammation and trauma. Owing to high risk of rupture, they require early treatment to prevent lethal complications. Knowledge of the various approaches of embolization of pseudoaneurysms and different embolic materials used in the management of visceral artery pseudoaneurysms is essential for successful and safe embolization. We review and illustrate the endovascular, percutaneous and endoscopic ultrasound techniques used in the treatment of visceral artery pseudoaneurysm and briefly discuss the embolic materials and their benefits and risks.

  6. [Aortic valve preservation in Marfan syndrome. Initial experience].

    Science.gov (United States)

    Forteza, Alberto; Cortina, Jose M; Sánchez, Violeta; Centeno, Jorge; López, M Jesús; Pérez de la Sota, Enrique; Rufilanchas, Juan J

    2007-05-01

    Preservation of the aortic valve using the technique described by David has been shown to be as effective as the Bentall-De Bono procedure. It avoids both the need for long-term anticoagulation and the complications associated with mechanical prostheses. We report our initial experience using this technique in patients with Marfan syndrome. Between April 2004 and April 2006, we used the David reimplantation technique in 40 patients with an aortic root aneurysm. Eighteen patients had Marfan syndrome. Their median age was 29 years (13-55 years). Echocardiography showed that the median diameter of the aortic sinus was 53 mm (46-59 mm). In 17 patients, aortic valve preservation was possible. No patient died during hospitalization and there were no significant complications. On echocardiography at discharge, no patient had greater than grade-II aortic regurgitation. During a median follow-up period of 8 months (1-24 months), one patient died due to rupture of an abdominal aneurysm. The others are all in New York Heart Association class I. Preservation of the aortic valve by means of valve reimplantation produced excellent results. It avoided both the thromboembolic and hemorrhagic complications associated with prostheses and the need for long-term anticoagulation. If reimplanted valves continue to function adequately over the long term, this technique should become the treatment of choice for aneurysms of the ascending aorta in patients with Marfan syndrome.

  7. Renal artery pseudoaneurysm

    Directory of Open Access Journals (Sweden)

    Luiz Inácio Roman

    Full Text Available Abstract The renal artery pseudoaneurysm embody a rare vascular complication coming of percutaneous procedures, renal biopsy, nephrectomy, penetrating traumas and more rarely blunt traumas. The clinical can be vary according the patient, the haematuria is the symptom more commom. Is necessary a high level of clinical suspicion for your diagnosis, this can be elucidated by through complementary exams as the eco-color Doppler and the computed tomography scan (CT. This report is a case of a patient submitted a right percutaneous renal biopsy and that, after the procedure started with macroscopic haematuria, urinary tenesmus and hypogastric pain. The diagnosis of pseudoaneurysm was given after one week of evolution when the patient was hospitalized because gross haematuria, tachycardia, hypotension and hypochondrium pain. In the angiotomography revealed a focal dilation of the accessory right renal inferior polar artery, dilation of renal pelvis and all the ureteral course with presence hyperdenso material (clots inside the middle third of the ureter. The treatment for the majority of this cases are conservative, through arterial embolization, indicated for thouse of smaller dimensions in patients who are hemodynamically stable. However, it was decided by clinical treatment with aminocaproic acid 1 g, according to previous studies for therapy of haematuria. The patient received discharge without evidence of macroscopic haematuria and with normal renal ultrasound, following ambulatory care.

  8. Aortic Dissection Type A in Alpine Skiers

    Science.gov (United States)

    Schachner, Thomas; Fischler, Nikolaus; Dumfarth, Julia; Bonaros, Nikolaos; Krapf, Christoph; Schobersberger, Wolfgang; Grimm, Michael

    2013-01-01

    Patients and Methods. 140 patients with aortic dissection type A were admitted for cardiac surgery. Seventy-seven patients experienced their dissection in the winter season (from November to April). We analyzed cases of ascending aortic dissection associated with alpine skiing. Results. In 17 patients we found skiing-related aortic dissections. Skiers were taller (180 (172–200) cm versus 175 (157–191) cm, P = 0.008) and heavier (90 (68–125) kg versus 80 (45–110) kg, P = 0.002) than nonskiers. An extension of aortic dissection into the aortic arch, the descending thoracic aorta, and the abdominal aorta was found in 91%, 74%, and 69%, respectively, with no significant difference between skiers and nonskiers. Skiers experienced RCA ostium dissection requiring CABG in 17.6% while this was true for 5% of nonskiers (P = 0.086). Hospital mortality of skiers was 6% versus 13% in nonskiers (P = 0.399). The skiers live at an altitude of 170 (0–853) m.a.s.l. and experience their dissection at 1602 (1185–3105; P < 0.001) m.a.s.l. In 82% symptom start was during recreational skiing without any trauma. Conclusion. Skiing associated aortic dissection type A is usually nontraumatic. The persons affected live at low altitudes and practice an outdoor sport at unusual high altitude at cold temperatures. Postoperative outcome is good. PMID:23971024

  9. Assessment of ventriculo-vascular properties in repaired coarctation using cardiac magnetic resonance-derived aortic, left atrial and left ventricular strain

    Energy Technology Data Exchange (ETDEWEB)

    Shang, Quanliang [University of Nebraska College of Medicine and Children' s Hospital and Medical Center, Division of Pediatric Cardiology, Omaha, NE (United States); Central South University, Department of Radiology, Second Xiangya Hospital, Changsha, Hunan Province (China); Sarikouch, Samir; Beerbaum, Philipp [Hannover Medical School, Hannover (Germany); Patel, Shivani; Danford, David A.; Kutty, Shelby [University of Nebraska College of Medicine and Children' s Hospital and Medical Center, Division of Pediatric Cardiology, Omaha, NE (United States); Schuster, Andreas [Department of Cardiology and Pneumonology, Georg-August-University and German Center for Cardiovascular Research (DZHK, Partner Site), Goettingen (Germany); Steinmetz, Michael [Department of Pediatric Cardiology, Georg-August-University and German Center for Cardiovascular Research (DZHK, Partner Site), Goettingen (Germany); Ou, Phalla [University Paris Diderot, Department of Radiology, Hospital Bichat, APHP, Paris (France)

    2017-01-15

    In patients with repaired coarctation of aorta (CoA), we assessed ventriculo-vascular characteristics using CMR-derived aortic area strain (AAS), left atrial (LA) and left ventricular (LV) longitudinal and circumferential strain (LS, CS). Seventy-five subjects including 50 with repaired CoA divided into hypertensive (n = 25), normotensive (n = 25) and 25 controls were studied. AAS was measured at 3 levels: ascending aorta, proximal descending and descending aorta. LA and LV LS were measured using CMR-feature tracking. LA and LV end-diastolic volumes, ejection fraction (EF) and mass were measured. Mean patient age was 19.7 ± 6.7 and controls 23 ± 15 (years). All strains (LA, LV, ascending and descending aortic) were lower in CoA subgroups compared to controls except the AAS at diaphragm, which was not different. Comparisons between hypertensive and normotensive CoA showed no differences in LV mass, LV volumetric indices, and LA and LV strain indices; however, ascending AAS was lower in hypertensive subgroup (p = 0.02). Ascending AAS was correlated with LV mass (r = -0.4, p = 0.005), LVEF (r = -0.4, p = 0.004), systolic blood pressure (r = -0.5, p = 0.0001) and LVLS (r = 0.5, p = 0.001). Ascending AAS correlated with LV mass, EF and LVLS. In hypertensive CoA, ascending AAS was reduced compared to normotensive CoA and controls, indicating vascular remodelling differences influenced by ongoing hypertension. (orig.)

  10. Splenic Artery Pseudoaneurysm Presenting as Massive Hematemesis: A Diagnostic Dilemma

    Directory of Open Access Journals (Sweden)

    Peeyush Varshney

    2014-01-01

    Full Text Available Introduction. Splenic artery Pseudoaneurysm, a complication of chronic pancreatitis, presenting as massive hematemesis is a rare presentation. Case Report. We present a case of 38-year-old male admitted with chief complaints of pain in the upper abdomen and massive hematemesis for the last 15 days. On examination there was severe pallor. On investigating the patient, Hb was 4.0 gm/dL, upper GI endoscopy revealed a leiomyoma in fundus of stomach, and EUS Doppler also supported the UGI findings. On further investigation of the patient, CECT of the abdomen revealed a possibility of distal pancreatic carcinoma encasing splenic vessels and infiltrating the adjacent structure. FNA taken at the time of EUS was consistent with inflammatory pathology. Triple phase CT of the abdomen revealed a splenic artery pseudoaneurysm with multiple splenic infarcts. After resuscitation we planned an emergency laparotomy; splenic artery pseudoaneurysm densely adherent to adjacent structures and associated with distal pancreatic necrosis was found. We performed splenectomy with repair of the defect in the stomach wall and necrosectomy. Postoperative course was uneventful and patient was discharged on day 8. Conclusion. Pseudoaneurysm can be at times a very difficult situation to manage; options available are either catheter embolisation if patient is vitally stable, or otherwise, exploration.

  11. Unicuspid aortic valve disease: a magnetic resonance imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Debl, K.; Buchner, S.; Heinicke, N.; Riegger, G.; Luchner, A. [Klinik und Poliklinik fuer Innere Medizin II, Universitaetsklinikum Regensburg (Germany); Djavidani, B.; Poschenrieder, F.; Feuerbach, S. [Inst. fuer Roentgendiagnostik, Universitaetsklinikum Regensburg (Germany); Schmid, C.; Kobuch, R. [Klinik und Poliklinik fuer Herz-, Thorax- und herznahe Gefaesschirurgie, Universitaetsklinikum Regensburg (Germany)

    2008-11-15

    Purpose: congenitally malformed aortic valves are a common finding in adults with aortic valve disease. Most of these patients have bicuspid aortic valve disease. Unicuspid aortic valve disease (UAV) is rare. The aim of our study was to describe valve morphology and the dimensions of the proximal aorta in a cohort of 12 patients with UAV in comparison to tricuspid aortic valve disease (TAV) using magnetic resonance imaging (MRI). Materials and methods/results: MRI studies were performed on a 1.5 T scanner in a total of 288 consecutive patients with aortic valve disease. 12 aortic valves were retrospectively classified as UAV. Annulus areas and dimensions of the thoracic aorta were retrospectively compared to a cohort of 103 patients with TAV. In UAV, valve morphology was unicuspid unicommissural with a posterior commissure in all patients. Mean annulus areas and mean diameters of the ascending aorta were significantly greater in UAV compared to TAV (12.6 {+-} 4.7 cm{sup 2} vs. 8.7 {+-} 2.3 cm{sup 2}, p < 0.01 and 4.6 {+-} 0.7 cm vs. 3.6 {+-} 0.5 cm, p < 0.0001, respectively), while no differences were observed in the mean diameters of the aortic arch (2.3 {+-} 0.6 cm vs. 2.3 {+-} 0.4 cm, p = 0.69). The diameters of the descending aorta were slightly smaller in UAV compared to TAV (2.2 {+-} 0.5 cm vs. 2.6 {+-} 0.3 cm, p < 0.05). (orig.)

  12. Endovascular Treatment of a Vertebral Artery Pseudoaneurysm Following Posterior C1-C2 Transarticular Screw Fixation

    International Nuclear Information System (INIS)

    Mendez, Jose C.; Gonzalez-Llanos, Francisco

    2005-01-01

    We present a case of vertebral artery pseudoaneurysm after a posterior C1-C2 transarticular screw fixation procedure that was effectively treated with endovascular coil occlusion. Vertebral artery pseudoaneurysm complicating posterior C1-C2 transarticular fixation is extremely rare, with only one previous case having been reported previously. Endovascular occlusion is better achieved in the subacute phase of the pseudoaneurysm, when the wall of the pseudoaneurysm has matured and stabilized. Further follow-up angiographies are mandatory in order to confirm that there is no recurrence of the lesion

  13. Thrombosed Popliteal Artery Pseudoaneurysm as Herald of Tibial Osteochondroma

    Directory of Open Access Journals (Sweden)

    A.M. Ruales Romero

    Full Text Available Background: Osteochondroma is the most common non-malignant tumour of bone, accounting for approximately one third of benign lesions in the skeleton. They often develop around the knee in the distal femur and in the proximal tibia and fibula. They present as a painless slow growing mass during adolescence and have been reported to cause damage to adjacent structures such as blood vessels; arterial damage is more common than venous injury and is usually a result of compression, stretching, and rubbing of the arterial wall. Such lesions include stenosis, thrombosis, and pseudoaneurysm formation possibly causing lower limb claudication or acute limb ischemia. Methods: An 18 year old male patient with a 4 week history of pain, hematoma, and oedema of the left calf without previous trauma is reported. A computed tomography scan (CT revealed a large popliteal artery pseudoaneurysm and its close relationship to a protrusion of the proximal tibia. Results: The popliteal artery was repaired by an external saphenous patch and the exostosis was removed. The patient had palpable popliteal and distal pulses after surgery and during the first year follow-up. Conclusions: Tibial osteochondroma should be considered in the differential diagnosis in young patients, among the potential causes of pseudoaneurysm of the femoral or popliteal artery. Surgical repair should be performed to restore normal blood flow with resection of the exostosis to prevent recurrence. Keywords: Popliteal artery, Pseudoaneurysm, Tibial exostosis, Osteochondroma

  14. Presentation of an uncommon form of aortic dissection and rupture in Marifoan syndrome

    International Nuclear Information System (INIS)

    Delgado, I.; Ruiz, R.; Villanueva, J.M.; Fernandez Cueto, J.L.

    1995-01-01

    In Marfan syndrome, aneurysmatic enlargement of ascending aorta and dissection starting at the root are the most common cardiovascular complications. We present an infrequent case of a 15-year-old patient with a typical case of Marfan syndrome. CT disclosed an aorta and aortic arch of normal size with dissection originating distally with respect to the point where left subclavian artery arises. The disecction extended to descending aorta and to iliac and femoral arteries. Aortic rupture occurred in the arch, with massive hemothorax. The CT findings were confirmed at necropsy. 9 refs

  15. A composed graft for subclavian artery reconstruction in case of redo surgery for aortic coarctation

    Directory of Open Access Journals (Sweden)

    Fabrizio Sansone

    2013-01-01

    Full Text Available We report the case of a 66-year-old woman admitted to the intensive care unit (ICU for ongoing dyspnea and hemoptoe. She was operated upon in 1979 for aortic coarctation by the interposition of a 14 mm Dacron prosthesis from the left subclavian artery to descending aorta. Clinical evaluation performed over the years was normal with no signs of cardiac failure or prosthesis malfunctioning. The computed tomography scans (CT showed a progressive increase of the descending aorta diameters and the onset of a pseudo-aneurysm of 50 mm in diameter. Patient was re-operated through a median sternotomy enlarged by a left thoracotomy and intra-operative findings revealed the pseudo-aneurysm originating from a dehiscence of the proximal suture. In order to allow a safe reconstruction of the dilated subclavian artery, a T-shaped composed graft was confectioned and then sutured to the descending aorta and the subclavian artery, respectively. Post-operative course was uneventful and three months CT scan showed a normal position of the composed graft.

  16. Postpartum Hemorrhage Resulting from Pelvic Pseudoaneurysm: A Retrospective Analysis of 588 Consecutive Cases Treated by Arterial Embolization

    Energy Technology Data Exchange (ETDEWEB)

    Dohan, Anthony, E-mail: anthony.dohan@lrb.aphp.fr; Soyer, Philippe, E-mail: philippe.soyer@lrb.aphp.fr; Subhani, Aqeel, E-mail: drsubhani07@gmail.com [Hopital Lariboisiere, Assistance Publique-Hopitaux de Paris, Department of Abdominal and Interventional Imaging (France); Hequet, Delphine, E-mail: delphine.hequet@gmail.com [Universite Paris-Diderot (France); Fargeaudou, Yann, E-mail: yannfargeaudou4@hotmail.com [Hopital Lariboisiere, Assistance Publique-Hopitaux de Paris, Department of Abdominal and Interventional Imaging (France); Morel, Olivier, E-mail: olivier.morel17@gmail.com [Maternite Universitaire de Nancy, Universite Henri Poincare Nancy 1 (France); Boudiaf, Mourad, E-mail: mourad.boudiaf@lrb.aphp.fr [Hopital Lariboisiere, Assistance Publique-Hopitaux de Paris, Department of Abdominal and Interventional Imaging (France); Gayat, Etienne, E-mail: etienne.gayat@9online.fr [Hopital Lariboisiere, Assistance Publique-Hopitaux de Paris, Department of Anesthesiology and Intensive Care Medicine (France); Barranger, Emmanuel, E-mail: emmanuel.barranger@lrb.aphp.fr [Universite Paris-Diderot (France); Dref, Olivier Le, E-mail: olivier.ledref@lrb.aphp.fr; Sirol, Marc, E-mail: marc.sirol@lrb.aphp.fr [Hopital Lariboisiere, Assistance Publique-Hopitaux de Paris, Department of Abdominal and Interventional Imaging (France)

    2013-10-15

    Objective: This study was designed to determine the incidence of arterial pseudoaneurysm in patients presenting with postpartum hemorrhage (PPH), to analyze the angiographic characteristics of pseudoaneurysms that cause PPH, and to evaluate the effectiveness of pelvic arterial embolization for the treatment of this condition.Study designEighteen women with pelvic arterial pseudoaneurysm were retrieved from a series of 588 consecutive patients with PPH treated by arterial embolization. Clinical files, angiographic examinations, and procedure details were reviewed. Results: The incidence of pseudoaneurysm was 3.06 % (18/588; 95 % confidence interval (CI): 1.82-4.8 %). A total of 20 pseudoaneurysms were found; 15/20 (75 %) were located on the uterine arteries. Angiography revealed extravasation of contrast material from pseudoaneurysm indicating rupture in 9 of 18 (50 %) patients. Arterial embolization was performed using gelatin sponge alone in 12 of 18 (67 %) patients or in association with metallic coils in 5 of 18 (28 %) patients or n-butyl-2-cyanoacrylate in 1 of 18 (6 %) patients. Arterial embolization allowed controlling the bleeding in all patients after one or two embolization sessions in 17 of 18 (94 %) and 1 of 18 patients (6 %) respectively, without complications, obviating the need for further surgery. Conclusions: Pseudoaneurysm is rarely associated with PPH. Arterial embolization is an effective and safe procedure for the treatment of PPH due to uterine or vaginal artery pseudoaneurysm. Our results suggest that gelatin sponge is effective for the treatment of ruptured pseudoaneurysms, although we agree that our series does not contain sufficient material to allow drawing definitive conclusions with respect to the most effective embolic material.

  17. Towards the evaluation of the pathological state of ascending thoracic aneurysms: integration of in-vivo measurements and hemodynamic simulations

    Science.gov (United States)

    Boccadifuoco, Alessandro; Mariotti, Alessandro; Celi, Simona; Martini, Nicola; Salvetti, Maria Vittoria

    2016-11-01

    Ascending thoracic aortic aneurysms are cardiovascular diseases consisting in a dilation of the ascending thoracic aorta. Since indicating a weakness of the arterial wall, they can lead to major complications with significant mortality rate. Clinical decisions about surgery are currently based on the maximum aortic diameter, but this single index does not seem a reliable indicator of the pathological state of the aorta. Numerical simulations of the blood flow inside the aneurysm may give supplementary information by quantifying important indices that are difficult to be measured, like the wall shear stress. Our aim is to develop an efficient platform in which in-vivo measurements are used to perform the hemodynamic simulations on a patient-specific basis. In particular, we used real geometries of thoracic aorta and focused on the use of clinical information to impose accurate boundary conditions at the inlet/outlets of the computational model. Stochastic analysis was also performed, to evaluate how uncertainties in the boundary parameters affect the main hemodynamic indicators, by considering both rigid and deformable walls. Stochastic calibration of numerical parameters against clinical data is in progress and results will be possibly shown.

  18. With computed tomography confirmed anterolateral left ventricular pseudoaneurysm in patient with dilatative alcoholic cardiomyopathy

    International Nuclear Information System (INIS)

    Letonja, Mitja; Letonja, Marija Santl

    2011-01-01

    Pseudoaneurysms are rare complications of myocardial infarction with propensity for rupture. There is still a challenge with which diagnostic imaging we performed a final diagnosis of pseudoaneurysm and differentiate it from true aneurysm what is clinically important due to the different treatment. We presented the unusual case of a 56-year-old man with signs of decompensated heart failure which had worsened a few months before hospitalization. We believed that during worsening of symptoms the patient suffered a silent myocardial infarction complicated by subacute free wall rupture which resulted into left ventricular pseudoaneurysm formation without tamponade. Echocardiography showed dilatative cardiomyopathy which was already present years before and a very rare location of the left ventricular pseudoaneurysm on the anterolateral part of the left ventricle. Pseudoaneurysm was confirmed with CT scan. Due to the severity of contractile dysfunction and no response in treatment for congestive heart failure the directive for the resection was tempered and the patient died due to the progressive heart failure and embolic phenomena. This report shows the importance of non-invasive imaging diagnostic evaluation of acute decompensated heart failure where echocardiography and chest X-ray are the first diagnostic steps. Based on those findings further imaging diagnostic steps must be performed such as CT scan in our case which finally confirms left ventricular pseudoaneurysm with dilatative cardiomyopathy

  19. The great imitator: IgG4 periaortitis masquerading as an acute aortic syndrome on computed tomographic angiography

    OpenAIRE

    Moore, Drew W.; Hansen, Neil J.; DiMaio, Dominick J.; Harrison, William L.

    2016-01-01

    We present the case of a 52-year-old woman who presented to the emergency department with chest and neck pain. Initial cervical spine magnetic resonance imaging shows an abnormal flow void in the left vertebral artery, which prompted a computed tomographic angiogram. This demonstrated a hyperdense thickened ascending aortic wall, which extended into the great vessel origins. Clinically and radiographically interpreted as an acute aortic syndrome and/or intramural hematoma, the patient underwe...

  20. Efficacy of a Self-Expandable Porous Stent as the Sole Curative Treatment for Extracranial Carotid Pseudoaneurysms.

    Science.gov (United States)

    Chen, Peng Roc; Edwards, Nancy J; Sanzgiri, Aditya; Day, Arthur L

    2016-04-01

    Extracranial carotid pseudoaneurysms are uncommon vascular lesions. Even with conservative management complications can happen, such as delayed cerebral embolization or symptoms due to flow limitation. Although endovascular therapy can be curative, literature demonstrating a preferred technique is scant. Our goal was to evaluate the use of 1 technique only-the deployment of overlapping self-expandable porous stents-to treat a series of extracranial carotid pseudoaneurysms. From 2008 to 2014, 14 consecutive cases of symptomatic extracranial carotid pseudoaneurysms were managed with single or multilayer porous stents at our institution. Each patient underwent a standardized angiographic follow-up at 6 months. Twelve patients also received a follow-up computed tomography angiogram at 12 months, and yearly thereafter (median radiographic follow-up, 38 months). The total clinical follow-up period ranged between 6 and 69 months (median, 46 months). In our series, each of the extracranial carotid pseudoaneurysms appeared to be the result of carotid artery dissection with associated carotid stenosis at the origin of every pseudoaneurysm. Endovascular treatment consisted of 1-3 layers of self-expandable porous stents placed without balloon angioplasty. Immediately after stenting angiographic images were notable for stagnant opacification of the pseudoaneurysm through the stent(s). All pseudoaneurysms were completely obliterated by the 6-month follow-up angiogram and remained so throughout the radiographic follow-up period. Complications were minimal, consisting of 1 patient developing a mild Horner's syndrome after treatment that resolved during clinical follow-up. Extracranial carotid pseudoaneurysms can be successfully obliterated with the use of porous, self-expandable stents. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. A Case of Late Femoral Pseudoaneurysm Caused by Stent Disconnection

    International Nuclear Information System (INIS)

    Rivolta, Nicola; Fontana, Federico; Piffaretti, Gabriele; Tozzi, Matteo; Carrafiello, Gianpaolo

    2010-01-01

    We present the case of a late superficial femoral artery stent disconnection causing an asymptomatic pseudoaneurysm successfully treated with a stent-graft. A 67-year-old female was referred to our department for evaluation of claudication of the left lower limb and was diagnosed to have a total occlusion of the superficial femoral artery. Three nitinol stents were used to revascularize this artery. At 48 months, duplex-ultrasonography control revealed the presence of a 45-mm saccular femoral dilatation; X-rays and CT angiography showed fractures of the proximal stents and the presence of a pseudoaneurysm at the site of the distal stents disconnection. The pseudoaneurysm was excluded using two stent-grafts. We conclude that patients and surgeons should be aware of structural complications with all stents. Rigorous follow-up controls should be mandatory. Endovascular repair proved to be feasible and durable to manage a previous endovascular procedure.

  2. Radiological evaluation of ventricular septal defect with aortic insufficiency - An analysis of cineangiography in 15 cases -

    International Nuclear Information System (INIS)

    Park, Jae Hyung; Yeon, Kyung Mo; Han, Man Chung

    1981-01-01

    Fifteen cases of ventricular septal defect with aortic insufficiency were diagnosed radiographically and confirmed after operation at Seoul National University Hospital in recent two half years since 1979. Cineangiographies of ascending aorta and left ventricle were done in those cases and revealed some characteristic findings. The results of the analysis are as follow: 1. Among the 15 cases, 14 cases were male and 1 case was female. Age distribution was from 7 years to 23 years. 2. Those 15 cases were corresponded to 8% among total 193 cases of ventricular septal defect, to 11% among total 135 cases of aortic insufficiency and especially to 48% among 48 cases of aortic insufficiency below age of 20 years. 3. After operation, 11 cases were confirmed as subpulmonary type ventricular septal defect and 4 cases as subcristal type. The sizes of the ventricular septal defects were ranged between 0.6 and 2.5 cm in diameter. 4. Regurgitation of contrast media was noticed in cine aortography of all cases, and the grades of regurgitation were II-III/IV in 13 cases. 5. Various types of herniated aortic cusp through ventricular septal defect were seen. In the cases of subpulmonary ventricular septal defect characteristic saccular aneurysm was found in 7 cases. Asymmetry or mild bulging of aortic sinus was found in the cases of subcristal ventricular septal defect. 6. Infundibular stenosis was found in 3 cases with right ventriculography and those were caused by the herniated saccular aneurysm of aortic cusp. 7. It is essential for the diagnosis of ventricular septal defect with aortic insufficiency to undertake biplane cineangiography of ascending aorta and left ventricle in long axial view and right ventriculography should be done in suspicion of infundibular pulmonary stenosis

  3. Life-threatening hemobilia caused by hepatic pseudoaneurysm after T-tube choledochostomy: report of a case

    Directory of Open Access Journals (Sweden)

    Wu Hurng-Sheng

    2010-07-01

    Full Text Available Abstract Background Hemobilia is a rare but lethal biliary tract complication. There are several causes of hemobilia which might be classified as traumatic or nontraumatic. Hemobilia caused by pseudoaneurysm might result from hepatobiliary surgery or percutaneous interventional hepatobiliary procedures. However, to our knowledge, there are no previous reports pertaining to hemobilia caused by hepatic pseudoaneurysm after T-tube choledochostomy. Case presentation A 65-year-old male was admitted to our hospital because of acute calculous cholecystitis and cholangitis. He underwent cholecystectomy, choledocholithotomy via a right upper quadrant laparotomy and a temporary T-tube choledochostomy was created. However, on the 19th day after operation, he suffered from sudden onset of hematemesis and massive fresh blood drainage from the T-tube choledochostomy. Imaging studies confirmed the diagnosis of pseudoaneurysm associated hemobilia. The probable association of T-tube choledochostomy with pseudoaneurysm and hemobilia is also demonstrated. He underwent emergent selective microcoils emobolization to occlude the feeding artery of the pseudoaneurysm. Conclusions Pseudoaneurysm associated hemobilia may occur after T-tube choledochostomy. This case also highlights the importance that hemobilia should be highly suspected in a patient presenting with jaundice, right upper quadrant abdominal pain and upper gastrointestinal bleeding after liver or biliary surgery.

  4. Splenic artery pseudoaneurysm as a complication of pancreatic pseudocyst

    Directory of Open Access Journals (Sweden)

    Micković Saša

    2011-01-01

    Full Text Available Introduction. Pancreatic pseudocyst presented as pseudoaneurysm of the splenic artery is a potential serious complication in patients with chronic pancreatitis. Case report. A 42-year-old male patient with a long-standing evolution of chronic pancreatitis and 8-year long evolution of pancreas pseudocyst was referred to the Military Medical Academy, Belgrade due to worsening of the general condition. At admission, the patient was cachectic, febrile, and had the increased values of amylases in urine and sedimentation (SE. After clinical and diagnostic examination: laboratory assessment, esophagogastroduodenoscopy (EGDS, ultrasonography (US, endoscopic ultrasonography (EUS, multislice computed scanner (MSCT angiography, pseudoaneurysm was found caused by the conversion of pseudocyst on the basis of chronic pancreatitis. The patient was operated on after founding pancreatic pseudocyst, which caused erosion of the splenic artery and their mutual communication. Postoperative course was duly preceded without complications with one year follow-up. Conclusion. Angiography is the most reliable and the safest method for diagnosing hemorrhagic pseudocysts when they clinically present as pseudoaneurysms. A potentially dangerous complication in the presented case was treated surgically with excellent postoperative results.

  5. [Mycotic aneurism in aortic arch by Aspergillus fumigatus: contribution of a case and review of the literature].

    Science.gov (United States)

    Burón Fernández, M R; Oruezábal Moreno, M J

    2005-09-01

    The micotic aneurisms by Aspergillus are rare and usually appear in the context of an invasive pulmonary aspergilosis, or by septicum embolism or direct extension from the lungs, for that reason the location the more frequents is in aortic arch and the ascending aorta.8 cases of micotic aneurisms by Aspergillus spp. have been described in literature between 1966 and 2000, being the most frequent location the ascending aorta or the aortic arch. The Aspergillus fumigatus is the isolated species with more frequency, affecting mainly to patients undergoing inmunosupression. The diagnosis of a micotic aneurism requires a high clinical suspicion, given to its peculiarity and the presence of inespecific symptoms, being frequently an accidental finding in an invasive pulmonary aspergilosis.The case of a patient with a micotic aneurism by A. fumigatus appears and we reviewed the similar cases previously disclosed.

  6. Quantitating aortic regurgitation by cardiovascular magnetic resonance: significant variations due to slice location and breath holding

    International Nuclear Information System (INIS)

    Chaturvedi, Abhishek; Hamilton-Craig, Christian; Cawley, Peter J.; Maki, Jeffrey H.; Mitsumori, Lee M.; Otto, Catherine M.

    2016-01-01

    Compare variability in flow measurements by phase contrast MRI, performed at different locations in the aorta and pulmonary artery (PA) using breath-held (BH) and free-breathing (FB) sequences. Fifty-seven patients with valvular heart disease, confirmed by echocardiography, were scanned using BH technique at 3 locations in the ascending aorta (SOV = sinus of Valsalva, STJ = sinotubular junction, ASC = ascending aorta at level of right pulmonary artery) and 2 locations in PA. Single FB measurement was obtained at STJ for aorta. Obtained metrics (SV = stroke volume, FV = forward volume, BV = backward volume, RF = regurgitant fraction) were evaluated separately for patients with aortic regurgitation (AR, n = 31) and mitral regurgitation (n = 26). No difference was noted between the two measurements in the PA. Significant differences were noted in measured SV at different aortic locations. SV measurements obtained at ASC correlated best with the measurements obtained in the PA. Strongest correlation of AR was measured at the STJ. Measurements of flow volumes by phase contrast MRI differ depending on slice location. When using stroke volumes to calculate pulmonary to systemic blood flow ratio (Qp/Qs), ASC should be used. For quantifying aortic regurgitation, measurement should be obtained at STJ. (orig.)

  7. Blunt splenic trauma: Can contrast enhanced sonography be used for the screening of delayed pseudoaneurysms?

    Energy Technology Data Exchange (ETDEWEB)

    Poletti, Pierre-Alexandre, E-mail: Pierre-Alexandre.Poletti@hcuge.ch [Department of Radiology, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland); Becker, Christoph D.; Arditi, Daniel; Terraz, Sylvain [Department of Radiology, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland); Buchs, Nicolas [Department of Surgery, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland); Shanmuganathan, Kathirkamanathan [Department of Diagnostic Radiology and Nuclear Medicine, 22 S. Greene Street, Baltimore, MD 21201 (United States); Platon, Alexandra [Department of Radiology, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland)

    2013-11-01

    Purpose: To assess the value of contrast-enhanced sonography (CES) for the detection of delayed post-traumatic splenic pseudo-aneurysms, usually considered an indication for angiographic embolization. Methods: Sixty-three consecutive hemodynamically stable trauma patients in whom admission CT displayed a splenic injury of grade II or higher (AAST classification), without evidence of vascular involvement, were included in the study. CES of the spleen using a second generation contrast agent was systematically performed within 48–72 h after admission, for the detection of a pooling of contrast media suggestive of pseudoaneurysm. Within 6 h after contrast-enhanced sonography, all patients underwent an abdominal CT for control purposes. CES results were compared to CT findings, which were considered the reference standard. This study received approval from the institutional ethical board. Results: CES showed a blush of contrast consistent with a pseudoaneurysm in 6 of the 63 patients. All were confirmed at subsequent control CT. Pooling of contrast was found at CT in 2 patients in whom contrast-enhanced sonography was negative. There was no false positive CES examination for the suspicion of pseudoaneurysms. When compared to CT, the sensitivity, specificity, positive and negative predictive values of CES to suggest a pseudoaneurysms, were 75% (6/8), 100% (55/55), 100% (6/6), and 96% (55/57), respectively. Conclusion: Our data suggest that CES may be useful for the screening of delayed traumatic splenic pseudoaneurysms: if a negative CES does not absolutely rule out a pseudoaneurysm, a positive CES warrants an angiography, without need of control CT.

  8. Blunt splenic trauma: Can contrast enhanced sonography be used for the screening of delayed pseudoaneurysms?

    International Nuclear Information System (INIS)

    Poletti, Pierre-Alexandre; Becker, Christoph D.; Arditi, Daniel; Terraz, Sylvain; Buchs, Nicolas; Shanmuganathan, Kathirkamanathan; Platon, Alexandra

    2013-01-01

    Purpose: To assess the value of contrast-enhanced sonography (CES) for the detection of delayed post-traumatic splenic pseudo-aneurysms, usually considered an indication for angiographic embolization. Methods: Sixty-three consecutive hemodynamically stable trauma patients in whom admission CT displayed a splenic injury of grade II or higher (AAST classification), without evidence of vascular involvement, were included in the study. CES of the spleen using a second generation contrast agent was systematically performed within 48–72 h after admission, for the detection of a pooling of contrast media suggestive of pseudoaneurysm. Within 6 h after contrast-enhanced sonography, all patients underwent an abdominal CT for control purposes. CES results were compared to CT findings, which were considered the reference standard. This study received approval from the institutional ethical board. Results: CES showed a blush of contrast consistent with a pseudoaneurysm in 6 of the 63 patients. All were confirmed at subsequent control CT. Pooling of contrast was found at CT in 2 patients in whom contrast-enhanced sonography was negative. There was no false positive CES examination for the suspicion of pseudoaneurysms. When compared to CT, the sensitivity, specificity, positive and negative predictive values of CES to suggest a pseudoaneurysms, were 75% (6/8), 100% (55/55), 100% (6/6), and 96% (55/57), respectively. Conclusion: Our data suggest that CES may be useful for the screening of delayed traumatic splenic pseudoaneurysms: if a negative CES does not absolutely rule out a pseudoaneurysm, a positive CES warrants an angiography, without need of control CT

  9. Uncontrolled Epistaxis Secondary to Traumatic Pseudoaneurysm of the Maxillary Artery

    Directory of Open Access Journals (Sweden)

    Eelam Adil

    2011-01-01

    Full Text Available We describe a rare case of traumatic pseudoaneurysm of the maxillary artery following a fall. The patient presented with epistaxis that could not be controlled with anterior and posterior nasal packing. She was urgently taken to the angiography suite for evaluation and ultimately underwent embolization of a left maxillary artery pseudoaneurysm with 500–700 micron Contour PVA followed by coiling with two 3 mm Tornado coils. Bleeding subsided after embolization, and the patient suffered no neurologic sequelae.

  10. An alternative noninvasive technique for the treatment of iatrogenic femoral pseudoaneurysms: stethoscope-guided compression.

    Science.gov (United States)

    Korkmaz, Ahmet; Duyuler, Serkan; Kalayci, Süleyman; Türker, Pinar; Sahan, Ekrem; Maden, Orhan; Selçuk, Mehmet Timur

    2013-06-01

    latrogenic femoral pseudoaneurysm is a well-known vascular access site complication. Many invasive and noninvasive techniques have been proposed for the management of this relatively common complication. In this study, we aimed to evaluate efficiency and safety of stethoscope-guided compression as a novel noninvasive technique in the femoral pseudoaneurysm treatment. We prospectively included 29 consecutive patients with the diagnosis of femoral pseudoaneurysm who underwent coronary angiography. Patients with a clinical suspicion of femoral pseudoaneurysm were referred to colour Doppler ultrasound evaluation. The adult (large) side of the stethoscope was used to determine the location where the bruit was best heard. Then compression with the paediatric (small) side of the stethoscope was applied until the bruit could no longer be heard and compression was maintained for at least two sessions. Once the bruit disappeared, a 12-hour bed rest with external elastic compression was advised to the patients, in order to prevent disintegration of newly formed thrombosis. Mean pseudoaneurysm size was 1.7 +/- 0.4 cmx 3.0 +/- 0.9 cm and the mean duration of compression was 36.2 +/- 8.5 minutes.Twenty-six (89.6%) of these 29 patients were successfully treated with stethoscope-guided compression. In 18 patients (62%), the pseuodoaneurysms were successfully closed after 2 sessions of 15-minute compression. No severe complication was observed. Stethoscope-guided compression of femoral pseudoaneurysms is a safe and effective novel technique which requires less equipment and expertise than other contemporary methods.

  11. Unicuspid aortic valve disease: a magnetic resonance imaging study

    International Nuclear Information System (INIS)

    Debl, K.; Buchner, S.; Heinicke, N.; Riegger, G.; Luchner, A.; Djavidani, B.; Poschenrieder, F.; Feuerbach, S.; Schmid, C.; Kobuch, R.

    2008-01-01

    Purpose: congenitally malformed aortic valves are a common finding in adults with aortic valve disease. Most of these patients have bicuspid aortic valve disease. Unicuspid aortic valve disease (UAV) is rare. The aim of our study was to describe valve morphology and the dimensions of the proximal aorta in a cohort of 12 patients with UAV in comparison to tricuspid aortic valve disease (TAV) using magnetic resonance imaging (MRI). Materials and methods/results: MRI studies were performed on a 1.5 T scanner in a total of 288 consecutive patients with aortic valve disease. 12 aortic valves were retrospectively classified as UAV. Annulus areas and dimensions of the thoracic aorta were retrospectively compared to a cohort of 103 patients with TAV. In UAV, valve morphology was unicuspid unicommissural with a posterior commissure in all patients. Mean annulus areas and mean diameters of the ascending aorta were significantly greater in UAV compared to TAV (12.6 ± 4.7 cm 2 vs. 8.7 ± 2.3 cm 2 , p < 0.01 and 4.6 ± 0.7 cm vs. 3.6 ± 0.5 cm, p < 0.0001, respectively), while no differences were observed in the mean diameters of the aortic arch (2.3 ± 0.6 cm vs. 2.3 ± 0.4 cm, p = 0.69). The diameters of the descending aorta were slightly smaller in UAV compared to TAV (2.2 ± 0.5 cm vs. 2.6 ± 0.3 cm, p < 0.05). (orig.)

  12. THE IMPACT OF DIAGNOSTIC DISCREPANCIES IN AORTIC DISSECTION MANAGEMENT

    Directory of Open Access Journals (Sweden)

    Abdalla Hassan

    2016-01-01

    Full Text Available Aortic dissection is uncommon with high mortality rate if untreated. We report a challenging case of long segment aortic dissection in which the dissection type was very difficult to identify due to limitations of the available imaging studies. 66-year-old male presented to us with 3 days history of chest pain and difficulty breathing. He is known to be hypertensive. In the emergency room, patient has systolic blood pressure >190. Chest X-ray showed widening of mediastinum. CT angiography of chest and abdomen showed an acute dissection of the thoracic aorta extending from the mid ascending aorta to the infra-renal aorta suggestive of Stanford type A aortic dissection. Transthoracic and Trans-esophageal echocardiography revealed a partially calcified intimal flap in the distal portion of the arch and in the descending thoracic aorta suggestive of Stanford type B aortic dissection. Medical treatment started, and repeated CT angiography was obtained and it confirmed type B aortic dissection. One week after discharge, patient was readmitted with severe neck pain and difficulty breathing. CT chest without contrast showed grossly stable appearance of type A dissection consistent with the first CT angiography. Cardiothoracic surgery immediately reevaluated the situation and recommended surgical intervention.

  13. Giant pseudoaneurysm from Vieussens' arterial ring.

    Science.gov (United States)

    Kocica, Mladen J; Vranes, Mile R; Djukic, Petar L; Mikic, Aleksandar Dj; Velinovic, Milos M; Havelka, Marija; Kanjuh, Vladimir I

    2004-11-01

    A giant coronary pseudoaneurysm of uncertain cause, arising from Vieussens' arterial ring, was preoperatively diagnosed in an oligosymptomatic female patient. Successful off-pump surgical excision without additional bypass grafting was performed. Difficulties in diagnostic algorithm, as well as possible cause and extremely rare localization were discussed.

  14. Four-dimensional flow MRI of stented versus stentless aortic valve bioprostheses

    Energy Technology Data Exchange (ETDEWEB)

    Kesteren, Floortje van [University of Amsterdam, Department of Radiology and Nuclear Medicine, Academic Medical Centre, Amsterdam (Netherlands); University of Amsterdam, Department of Cardiology, Academic Medical Centre, Amsterdam (Netherlands); Wollersheim, Laurens W.; Kaya, Abdullah; Mol, Bas A. de [University of Amsterdam, Department of Cardiothoracic Surgery, Academic Medical Centre, Amsterdam (Netherlands); Baan, Jan; Boekholdt, S.M. [University of Amsterdam, Department of Cardiology, Academic Medical Centre, Amsterdam (Netherlands); Nederveen, A.J.; Ooij, Pim van; Planken, R.N. [University of Amsterdam, Department of Radiology and Nuclear Medicine, Academic Medical Centre, Amsterdam (Netherlands)

    2018-01-15

    To evaluate aortic velocity, wall shear stress (WSS) and viscous energy loss (EL) of stented and stentless bioprostheses using 4D flow MRI 1 year after surgical aortic valve replacement. For this cross-sectional study 28 patients with stented (n = 14) or stentless (n = 14) bioprosthesis underwent non-contrast-enhanced 4D-flow MRI at 1.5 T. Analyses included a comparison of velocity, WSS and EL in the ascending aorta during peak systole for both spatially averaged values and a comparison of local differences using per-voxel analysis. No significant differences were found in peak and mean velocity (stented vs. stentless: 2.45 m/s vs. 2.11 m/s; p = 0.09 and 0.60 m/s vs. 0.62 m/s; p = 0.89), WSS (0.60 Pa vs. 0.59 Pa; p = 0.55) and EL (10.17 mW vs. 7.82 mW; p = 0.10). Per-voxel analysis revealed significantly higher central lumen velocity, and lower outer lumen velocity, WSS and EL for stentless versus stented prostheses. One year after aortic valve implantation with stented and stentless bioprostheses, velocity, WSS and EL were comparable when assessed for averaged values in the ascending aorta. However, the flow profile described with local analysis for stentless prosthesis is potentially favourable with a significantly higher central velocity profile and lower values for outer lumen velocity, WSS and EL. (orig.)

  15. Percutaneous Thrombin Injection to Complete SMA Pseudoaneurysm Exclusion After Failing of Endograft Placement

    International Nuclear Information System (INIS)

    Szopinski, Piotr; Ciostek, Piotr; Pleban, Eliza; Iwanowski, Jaroslaw; Krol, Malgorzata Serafin-; Marianowska, Agnieszka; Noszczyk, Wojciech

    2005-01-01

    Visceral aneurysms are potentially life-threatening vascular lesions. Superior mesenteric artery (SMA) pseudoaneurysms are a rare but well-recognized complication of chronic pancreatitis. Open surgical repair of such an aneurysm, especially in patients after previous surgical treatment, might be dangerous and risky. Stent graft implantation makes SMA pseudoaneurysm exclusion possible and therefore avoids a major abdominal operation. Percutaneous direct thrombin injection is also one of the methods of treating aneurysms in this area. We report a first case of percutaneous ultrasound-guided thrombin injection to complete SMA pseudoaneurysm exclusion after an unsuccessful endograft placement. Six-month follow-up did not demonstrate any signs of aneurysm recurrence

  16. Percutaneous N-Butyl cyanoacrylate embolization of a pancreatic pseudoaneurysm after failed attempts of transcatheter embolization

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ri Hyeon; Yoo, Roh Eul; Kim, Hyo Cheol [Seoul National University Medical Research Center, and Clinical Research Institute, Seoul National University Hospital, Seoul (Korea, Republic of)

    2014-10-15

    One common complication after major pancreatic surgery is bleeding. Herein we describe a case of pancreatic pseudoaneurysm which developed after pylorous preserving pancreaticoduodenectomy for common bile duct cancer. Three attempts of transcatheter embolization failed since feeders to the pseudoaneurysm had unfavorable anatomy. Direct percutaneous N-butyl cyanoacrylate injection was performed under fluoroscopy-guidance and the pseudoaneurysm was successfully treated. Percutaneous fluoroscopy-guided direct N-butyl cyanoacrylate injection may be a useful alternative when selective transcatheter embolization fails or is technically challenging.

  17. Aortic dilatation in Marfan syndrome: role of arterial stiffness and fibrillin-1 variants.

    Science.gov (United States)

    Salvi, Paolo; Grillo, Andrea; Marelli, Susan; Gao, Lan; Salvi, Lucia; Viecca, Maurizio; Di Blasio, Anna Maria; Carretta, Renzo; Pini, Alessandro; Parati, Gianfranco

    2018-01-01

    Marfan syndrome (MFS) is an autosomal dominant genetic disorder characterized by aortic root dilation and dissection and an abnormal fibrillin-1 synthesis. In this observational study, we evaluated aortic stiffness in MFS and its association with ascending aorta diameters and fibrillin-1 genotype. A total of 116 Marfan adult patients without history of cardiovascular surgery, and 144 age, sex, blood pressure and heart rate matched controls were enrolled. All patients underwent arterial stiffness evaluation through carotid-femoral pulse wave velocity (PWV) and central blood pressure waveform analysis (PulsePen tonometer). Fibrillin-1 mutations were classified based on the effect on the protein, into 'dominant negative' and 'haploinsufficient' mutations. PWV and central pulse pressure were significantly higher in MFS patients than in controls [respectively 7.31 (6.81-7.44) vs. 6.69 (6.52-6.86) m/s, P = 0.0008; 41.3 (39.1-43.5) vs. 34.0 (32.7-35.3) mmHg, P < 0.0001], with a higher age-related increase of PWV in MFS (β 0.062 vs. 0.036). Pressure amplification was significantly reduced in MFS [18.2 (15.9-20.5) vs. 33.4 (31.6-35.2)%, P < 0.0001]. Central pressure profile was altered even in MFS patients without aortic dilatation. Multiple linear regression models showed that PWV independently predicted aortic diameters at the sinuses of Valsalva (ß = 0.243, P = 0.002) and at the sinotubular junction (ß = 0.186, P = 0.048). PWV was higher in 'dominant negative' than 'haploinsufficient' fibrillin-1 mutations [7.37 (7.04-7.70) vs. 6.60 (5.97-7.23) m/s, P = 0.035], although this difference was not significant after adjustment. Aortic stiffness is increased in MFS, independently from fibrillin-1 genotype and is associated with diameters of ascending aorta. Alterations in central hemodynamics are present even when aortic diameter is within normal limits. Our findings suggest an accelerated arterial aging in MFS.

  18. Thoracic aorta 3D hemodynamics in pediatric and young adult patients with bicuspid aortic valve.

    Science.gov (United States)

    Allen, Bradley D; van Ooij, Pim; Barker, Alex J; Carr, Maria; Gabbour, Maya; Schnell, Susanne; Jarvis, Kelly B; Carr, James C; Markl, Michael; Rigsby, Cynthia; Robinson, Joshua D

    2015-10-01

    To evaluate the 3D hemodynamics in the thoracic aorta of pediatric and young adult bicuspid aortic valve (BAV) patients. 4D flow MRI was performed in 30 pediatric and young adult BAV patients (age: 13.9 ± 4.4 (range: [3.4, 20.7]) years old, M:F = 17:13) as part of this Institutional Review Board-approved study. Nomogram-based aortic root Z-scores were calculated to assess aortic dilatation and degree of aortic stenosis (AS) severity was assessed on MRI. Data analysis included calculation of time-averaged systolic 3D wall shear stress (WSSsys ) along the entire aorta wall, and regional quantification of maximum and mean WSSsys and peak systolic velocity (velsys ) in the ascending aorta (AAo), arch, and descending aorta (DAo). The 4D flow MRI AAo velsys was also compared with echocardiography peak velocity measurements. There was a positive correlation with both mean and max AAo WSSsys and peak AAo velsys (mean: r = 0.84, P max: r = 0.94, P max: rS  = 0.70, P < 0.001). AAo peak velocity was significantly higher when measured with echo compared with 4D flow MRI (2.1 ± 0.98 m/s versus 1.27 ± 0.49 m/s, P < 0.001). In pediatric and young adult patients with BAV, AS and peak ascending aorta velocity are associated with increased AAo WSS, while aortic dilation, age, and body surface area do not significantly impact AAo hemodynamics. Prospective studies are required to establish the role of WSS as a risk-stratification tool in these patients. © 2015 Wiley Periodicals, Inc.

  19. Spontaneous healing of cervical pseudoaneurysm in vertebral artery dissection under anticoagulant therapy

    International Nuclear Information System (INIS)

    Sommer, A.; Neff, W.; Schwartz, A.

    1998-01-01

    We report a 41-year-old woman with embolic stroke of the mid-pons attributed to embolism from vertebral artery dissection. Angiography revealed an occluded artery on one side and an incidental pseudoaneurysm of the midcervical portion of the vertebral artery on the other. After 3 months of warfarin therapy control angiography showed complete occlusion of the pseudoaneurysm. We discuss therapeutic choices and review the literature. (orig.)

  20. Optimal primary surgical management of infected pseudoaneurysm in intravenous drug abusers: ligation or reconstruction?

    International Nuclear Information System (INIS)

    Jamil, M.; Usman, R.; Afzal, M.; Malik, N.I.

    2017-01-01

    Objective: To find out the optimal primary surgical treatment options for infected pseudoaneurysm in intravenous drug abusers. Study Design: Cross sectional descriptive study. Place and Duration of Study: Department of Vascular Surgery, Combined Military Hospital Lahore, from Jan 2010 to Jun 2015. Material and Methods: A total of 31 consecutive patients with a history of intravenous drug abuse and an infected pseudoaneurysm in the groin or elbow, presenting in emergency department; were included in this study. All patients were primarily treated with ligation of the artery, excision of infected pseudoaneurysm and debridement of necrotic tissues. Only one patient underwent additional revascularization procedure. Results: All patients who underwent ligation and excision procedures did well initially. One (3.2%) patient developed severe distal ischemia after ligation of femoral artery within first 24 hours, so extra anatomic revascularization procedure was performed. Five (16.1%) patients required revascularization procedure after 16 weeks due to disabling distal ischemia. No amputation was needed and mortality rate was zero. Conclusion: Primary ligation of the artery with excision of infected pseudoaneurysm and necrotic material was found the optimal initial management for infected pseudoaneurysm in intravenous drug addicts. Ischemic complications if develop should be treated with early or late revascularization.

  1. Diagnosis and treatment of traumatic carotid cavernous fistula combined with sphenoid sinus pseudoaneurysm

    International Nuclear Information System (INIS)

    Chen Huairui; Bai Rulin; Huang Chengguang; Hu Guohan; Luo Chun; Yuan Guoliang; Lu Yicheng

    2008-01-01

    Objective: To explore the diagnosis and treatment of traumatic carotid cavernous fistula combined with sphenoid sinus pseudoaneurysm. Methods: Interventional diagnosed and treated 6 eases of traumatid carotid cavernous fistula combined with sphenoid sinus pseudoaneurysm. Results: 5 patients presented with recurrent massive epistaxis and symptoms of CCF caused by pseudoaneurysms and fistulas were occluded with detachable balloons and internal carotid arteries were reserved in 2 cases; of which, 1 case also had indirect carotid cavernous fistula in contralateral side, embolizated by trans facial vein approach with microcoil. Complete symptoms resolution was achieved in all cases, without procedure related complications. During the follow-up period, all patients returned to their work. Conclusions: Falling from high speed motorcycle without helmet may be one of the main causes of this disease. The site of strike mostly localize at the frontal and lateral aspects of the orbit. MRI scan is very helpful for the diagnosis before receiving angiography. Detachable balloon occlusion for the pseudoaneurysm and fistula is safe and efficient for the treatment. (authors)

  2. Influence of surgical implantation angle of left ventricular assist device outflow graft and management of aortic valve opening on the risk of stroke in heart failure patients

    Science.gov (United States)

    Chivukula, V. Keshav; McGah, Patrick; Prisco, Anthony; Beckman, Jennifer; Mokadam, Nanush; Mahr, Claudius; Aliseda, Alberto

    2016-11-01

    Flow in the aortic vasculature may impact stroke risk in patients with left ventricular assist devices (LVAD) due to severely altered hemodynamics. Patient-specific 3D models of the aortic arch and great vessels were created with an LVAD outflow graft at 45, 60 and 90° from centerline of the ascending aorta, in order to understand the effect of surgical placement on hemodynamics and thrombotic risk. Intermittent aortic valve opening (once every five cardiac cycles) was simulated and the impact of this residual native output investigated for the potential to wash out stagnant flow in the aortic root region. Unsteady CFD simulations with patient-specific boundary conditions were performed. Particle tracking for 10 cardiac cycles was used to determine platelet residence times and shear stress histories. Thrombosis risk was assessed by a combination of Eulerian and Lagrangian metrics and a newly developed thrombogenic potential metric. Results show a strong influence of LVAD outflow graft angle on hemodynamics in the ascending aorta and consequently on stroke risk, with a highly positive impact of aortic valve opening, even at low frequencies. Optimization of LVAD implantation and management strategies based on patient-specific simulations to minimize stroke risk will be presented

  3. Overview of current surgical strategies for aortic disease in patients with Marfan syndrome.

    Science.gov (United States)

    Miyahara, Shunsuke; Okita, Yutaka

    2016-09-01

    Marfan syndrome is a heritable, systemic disorder of the connective tissue with a high penetrance, named after Dr. Antoine Marfan. The most clinically important manifestations of this syndrome are cardiovascular pathologies which cause life-threatening events, such as acute aortic dissections, aortic rupture and regurgitation of the aortic valve or other artrioventricular valves leading to heart failure. These events play important roles in the life expectancy of patients with this disorder, especially prior to the development of effective surgical approaches for proximal ascending aortic disease. To prevent such catastrophic aortic events, a lower threshold has been recommended for prophylactic interventions on the aortic root. After prophylactic root replacement, disease in the aorta beyond the root and distal to the arch remains a cause for concern. Multiple surgeries are required throughout a patient's lifetime that can be problematic due to distal lesions complicated by dissection. Many controversies in surgical strategies remain, such as endovascular repair, to manage such complex cases. This review examines the trends in surgical strategies for the treatment of cardiovascular disease in patients with Marfan syndrome, and current perspectives in this field.

  4. Right circumflex retro-oesophageal aortic arch with coarctation of a high-positioned right arch

    International Nuclear Information System (INIS)

    Ahn, Kyung-Sik; Yong, Hwan Seok; Woo, Ok Hee; Kang, Eun-Young; Lee, Joo-Won

    2007-01-01

    We present a rare case of right circumflex retro-oesophageal aortic arch with coarctation of a high-positioned right arch. A 7-month-old boy presented with a cardiac murmur. Cardiac situs was normal and there was no evidence of an intracardiac shunt or patent ductus arteriosus. MR aortography revealed a right aortic arch that was high-positioned, tortuous and narrowed. This right aortic arch crossed the midline behind the oesophagus and continued as a left-sided descending aorta. The left common carotid and subclavian arteries arose from a large branching vascular structure that derived from the top of the left-sided descending aorta. The right common carotid artery arose from the ascending aorta. The proximal portion of the right common carotid artery showed very severe stenosis and poststenotic dilatation. The right subclavian artery originated distal to the narrowed and tortuous segment of the aortic arch. (orig.)

  5. Factitious aortic dissection leading to thoracotomy in a 20-year-old man.

    Science.gov (United States)

    Chambers, Elise; Yager, Joel; Apfeldorf, William; Camps-Romero, Eduardo

    2007-01-01

    A 20-year-old man presented to an emergency department with dramatic, sudden-onset, tearing chest pain. He also claimed to have been previously diagnosed with Ehler-Danlos syndrome and a previous Type I aortic dissection (intimal tear of ascending aorta), rapidly increasing his treating physician's suspicion of an emergent aortic dissection. The patient was quickly transferred to a large university hospital, where he underwent a median sternotomy and thoracotomy, with no aortic pathology found on operation and biopsy. After the patient's postoperative recovery, he was treated at a mental health facility, where he remained ambivalent about his psychiatric condition and did not respond well to treatment. This case report describes a unique case of factitious disorder that led to a serious operative intervention and subsequent psychiatric care and assesses factors that might have contributed to his hospital course.

  6. Contrast-enhanced magnetic resonance angiography of persistent fifth aortic arch in children

    International Nuclear Information System (INIS)

    Zhong, Yumin; Zhu, Ming; Sun, Aimin; Li, Yuhua; Jaffe, Richard B.; Gao, Wei

    2007-01-01

    Cine angiography and echocardiography have been utilized to diagnose congenital aortic arch anomalies. However, the visualization of great vessels by echocardiography is limited, while cine angiography requires cardiac catheterization with ionizing radiation. Contrast-enhanced magnetic resonance angiography (MRA) is a noninvasive modality suitable for visualization of congenital aortic arch anomalies. To evaluate the utility of contrast-enhanced MRA in the diagnosis of persistent fifth aortic arch, a rare congenital aortic arch anomaly, and to compare the diagnostic accuracy of MRA with that of echocardiography and cine angiography. In four pediatric patients, contrast-enhanced MRA studies were performed for diagnosing persistent fifth aortic arch. The findings of MRA were compared with echocardiographic findings and confirmed by cine angiography and operation. Transthoracic surface echocardiography noted an aberrant vessel arising from the ascending aorta in two of four patients; the etiology of this vessel was uncertain. In the other two patients a diagnosis of coarctation was made. Of the four patients, only one was diagnosed with interruption of the aortic arch. Contrast-enhanced MRA clarified uncertain echocardiographic findings, enabling the correct diagnosis of persistent fifth aortic arch with fourth aortic arch interruption in all four patients. Contrast-enhanced MRA is a safe, accurate, and fast imaging technique for the evaluation of persistent fifth aortic arch and may obviate the need for conventional cine angiography. Cardiac catheterization may be reserved for some types of complicated congenital heart disease and for obtaining hemodynamic information. (orig.)

  7. Traumatic pseudoaneurysm of the intracavernous ICA presenting with massive epistaxis: imaging diagnosis and endovascular treatment.

    Science.gov (United States)

    Han, M H; Sung, M W; Chang, K H; Min, Y G; Han, D H; Han, M C

    1994-03-01

    Traumatic pseudoaneurysm of the intracavernous internal carotid artery (ICA) is a very rare cause of epistaxis but is a life-threatening clinical situation when left untreated. The authors have experienced four cases of traumatic pseudoaneurysm involving the intracavernous ICA. Delayed massive epistaxes developed 1 to 8 months after trauma and initial transient epistaxis in all four patients. Three of the cases were successfully managed by the detachable balloon occlusion (DBO) of the ICA along with the aneurysm openings. In one case, a large pseudoaneurysm destroying a large area of the central skull base with peripheral blood clot was demonstrated on computed tomography, magnetic resonance imaging, and angiography; this patient died due to massive epistaxis before the trial of DBO. Imaging findings of pseudoaneurysms involving the intracavernous ICA in the four cases are described, and the role of endovascular treatment is discussed.

  8. Acute Aortic Dissection in a Third Trimester Pregnancy without Risk Factors

    Directory of Open Access Journals (Sweden)

    Elizabeth L Walters

    2011-05-01

    Full Text Available Spontaneous aortic dissection in pregnancy is rare and life threatening for both the mother and the fetus. Most commonly, it is associated with connective tissue disorders, cardiac valve variants, or trauma. We present the case of a 23-year-old previously healthy woman, 36 weeks pregnant with a syncopal episode after dyspnea and vomiting. She subsequently developed cardiac arrest and underwent aggressive resuscitation, emergent thoracotomy, and cesarean delivery without recovery. On autopsy, she was found to have an aortic dissection of the ascending aorta. This case is presented to raise awareness and review the literature and the clinical approach to critical care for pregnant patients. [West J Emerg Med. 2011;12(4:571–574.

  9. Interventional therapy of traumatic pseudoaneurysms in internal carotid artery siphon

    International Nuclear Information System (INIS)

    Tang Jun; Shang Jianqiang; Chen Jie; Li Fengxin; Liu Yanjun

    2007-01-01

    Objective: To determine the methods and results of treating traumatic pseudoaneurysms in siphon segment of internal carotid artery (ICA)by interventional therapy. Methods: Twelve cases of traumatic pseudoaneurysms in siphon segment of internal carotid artery were treated. The collateral circulation of Willis circle was observed after DSA. Different methods of treatment were applied according to the collateral circulation of Willis circle. Ten cases were treated by occlusion of ICA completely, 1 case was embolized by guglielmi detachable coil (GDC) only. Results: Nine of 12 treated by occlusion of ICA were cured. In the 3 cases who had poor collateral of Willis circle, one was cured by GDC embolization alone; one died 48 hours later after ICA occlusion though his consciousness and the activity of extremities were normal during the temporary balloon test occlusion (BTO) of ICA. One died during the training to improve the collateral of the Willis circle. Conclusion: ICA embolization is feasible for treatment of traumatic pseudoaneurysms in siphon segment of internal carotid artery after evaluating the collateral circulation of Willis circle. (authors)

  10. Differentiation defect in neural crest-derived smooth muscle cells in patients with aortopathy associated with bicuspid aortic valves

    Directory of Open Access Journals (Sweden)

    Jiao Jiao

    2016-08-01

    Full Text Available Individuals with bicuspid aortic valves (BAV are at a higher risk of developing thoracic aortic aneurysms (TAA than patients with trileaflet aortic valves (TAV. The aneurysms associated with BAV most commonly involve the ascending aorta and spare the descending aorta. Smooth muscle cells (SMCs in the ascending and descending aorta arise from neural crest (NC and paraxial mesoderm (PM, respectively. We hypothesized defective differentiation of the neural crest stem cells (NCSCs-derived SMCs but not paraxial mesoderm cells (PMCs-derived SMCs contributes to the aortopathy associated with BAV. When induced pluripotent stem cells (iPSCs from BAV/TAA patients were differentiated into NCSC-derived SMCs, these cells demonstrated significantly decreased expression of marker of SMC differentiation (MYH11 and impaired contraction compared to normal control. In contrast, the PMC-derived SMCs were similar to control cells in these aspects. The NCSC-SMCs from the BAV/TAA also showed decreased TGF-β signaling based on phosphorylation of SMAD2, and increased mTOR signaling. Inhibition of mTOR pathway using rapamycin rescued the aberrant differentiation. Our data demonstrates that decreased differentiation and contraction of patient's NCSC-derived SMCs may contribute to that aortopathy associated with BAV.

  11. A Case of Pseudoaneurysm of the Internal Carotid Artery Following Endoscopic Endonasal Pituitary Surgery: Endovascular Treatment with Flow-Diverting Stent Implantation

    Directory of Open Access Journals (Sweden)

    Ali Karadag

    2017-10-01

    Full Text Available Internal carotid artery (ICA pseudoaneurysm is a rare complication of endoscopic endonasal surgery occurring in 0.4–1.1% of cases. Pseudoaneurysms can subsequently result in other complications, such as subarachnoid hemorrhage, epistaxis, and caroticocavernous fistula with resultant death or permanent neurologic deficit. In this case, we illustrate endovascular treatment with a flow-diverting stent for an ICA pseudoaneurysm after endoscopic endonasal surgery for a pituitary adenoma in a 56-year-old male. Surgery was complicated by excessive intraoperative bleeding and emergent CT angiography confirmed an iatrogenic pseudoaneurysm on the anteromedial surface of the ICA. The pseudoaneurysm was treated endovascularly with flow-diverting stent implantation only. Follow-up CT angiography after three months demonstrated occlusion of the pseudoaneurysm.

  12. Spontaneous obliteration of right ventricular pseudoaneurysm after blunt chest trauma: Diagnosis and follow-up with multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Tae Kyung; Kang, Mi Jin; Kim, Jae Hyung [Sanggye Paik Hospital, Inje University College of Medicine, Seoul (Korea, Republic of)

    2014-06-15

    Right ventricular (RV) pseudoaneurysm caused by trauma is very rare. We report a case of RV pseudoaneurysm which resolved without surgical treatment in a patient who survived a falling accident. Echocardiography failed to identify the pseudoaneurysm. Electrocardiography-gated CT showed a 17-mm-sized saccular pseusoaneurysm arsing from the RV outflow tract with a narrow neck. Follow-up CT after two months showed spontaneous obliteration of the lesion.

  13. Aortic valve bypass surgery in severe aortic valve stenosis: Insights from cardiac and brain magnetic resonance imaging.

    Science.gov (United States)

    Mantini, Cesare; Caulo, Massimo; Marinelli, Daniele; Chiacchiaretta, Piero; Tartaro, Armando; Cotroneo, Antonio Raffaele; Di Giammarco, Gabriele

    2018-04-13

    To investigate and describe the distribution of aortic and cerebral blood flow (CBF) in patients with severe valvular aortic stenosis (AS) before and after aortic valve bypass (AVB) surgery. We enrolled 10 consecutive patients who underwent AVB surgery for severe AS. Cardiovascular magnetic resonance imaging (CMR) and brain magnetic resonance imaging were performed as baseline before surgery and twice after surgery. Quantitative flow measurements were obtained using 1.5-T magnetic resonance imaging (MRI) scanner phase-contrast images of the ascending aorta, descending thoracic aorta (3 cm proximally and distally from the conduit-to-aorta anastomosis), and ventricular outflow portion of the conduit. The evaluation of CBF was performed using 3.0-T MRI scanner arterial spin labeling (ASL) through sequences acquired at the gray matter, dorsal default-mode network, and sensorimotor levels. Conduit flow, expressed as the percentage of total antegrade flow through the conduit, was 63.5 ± 8% and 67.8 ± 7% on early and mid-term postoperative CMR, respectively (P surgery in patients with severe AS, cardiac output is split between the native left ventricular outflow tract and the apico-aortic bypass, with two-thirds of the total antegrade flow passing through the latter and one-third passing through the former. In our experience, CBF assessment confirms that the flow redistribution does not jeopardize cerebral blood supply. Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  14. Subclavian Artery Pseudoaneurysm Formation 3 Months after a Game of Rugby Union

    Directory of Open Access Journals (Sweden)

    T. Evans

    2015-01-01

    Full Text Available Pseudoaneurysms of the subclavian artery remain a rare complication after fracture of the clavicle. We report a case of delayed diagnosis of a subclavian artery pseudoaneurysm after a closed fracture of the clavicle in a 15-year-old patient, 3 months after the original injury while playing rugby union. Despite several attendances to the Emergency Department with vague symptoms, the final diagnosis was confirmed by duplex ultrasound and Computed Tomography of the thorax. Surgical repair was indicated due to acute limb ischaemia from distal embolisation from a large pseudoaneurysm, with the patient making a full recovery. This case highlights the need for clinical vigilance when assessing patients, particularly on repeated occasions when their recovery appears to be impaired. A thorough history and clinical examination can raise suspicion of even rare occurrences and aid prompt management.

  15. Peroneal Arteriovenous Fistula and Pseudoaneurysm: An Unusual Presentation

    Directory of Open Access Journals (Sweden)

    Kevin C. Ching

    2014-01-01

    Full Text Available Peroneal artery arteriovenous fistulas and pseudoaneurysms are extremely rare with the majority of reported cases due to penetrating, orthopedic, or iatrogenic trauma. Failure to diagnose this unusual vascular pathology may lead to massive hemorrhage or limb threatening ischemia. We report an interesting case of a 14-year-old male who presented with acute musculoskeletal pain of his lower extremity. Initial radiographs were negative. Further imaging workup revealed a peroneal arteriovenous fistula with a large pseudoaneurysm. After initial endovascular intervention was unsuccessful, the vessels were surgically ligated in the operating room. Pathology revealed papillary endothelial hyperplasia consistent with an aneurysm and later genetic testing was consistent with Ehlers-Danlos syndrome Type IV. This case illustrates an unusual cause of acute atraumatic musculoskeletal pain and uncommon presentation of Ehlers-Danlos syndrome.

  16. Redox stress in Marfan syndrome: Dissecting the role of the NADPH oxidase NOX4 in aortic aneurysm.

    Science.gov (United States)

    Jiménez-Altayó, Francesc; Meirelles, Thayna; Crosas-Molist, Eva; Sorolla, M Alba; Del Blanco, Darya Gorbenko; López-Luque, Judit; Mas-Stachurska, Aleksandra; Siegert, Ana-Maria; Bonorino, Fabio; Barberà, Laura; García, Carolina; Condom, Enric; Sitges, Marta; Rodríguez-Pascual, Fernando; Laurindo, Francisco; Schröder, Katrin; Ros, Joaquim; Fabregat, Isabel; Egea, Gustavo

    2018-04-01

    Marfan syndrome (MFS) is characterized by the formation of ascending aortic aneurysms resulting from altered assembly of extracellular matrix fibrillin-containing microfibrils and dysfunction of TGF-β signaling. Here we identify the molecular targets of redox stress in aortic aneurysms from MFS patients, and investigate the role of NOX4, whose expression is strongly induced by TGF-β, in aneurysm formation and progression in a murine model of MFS. Working models included aortae and cultured vascular smooth muscle cells (VSMC) from MFS patients, and a NOX4-deficient Marfan mouse model (Fbn1 C1039G/+ -Nox4 -/- ). Increased tyrosine nitration and reactive oxygen species levels were found in the tunica media of human aortic aneurysms and in cultured VSMC. Proteomic analysis identified nitrated and carbonylated proteins, which included smooth muscle α-actin (αSMA) and annexin A2. NOX4 immunostaining increased in the tunica media of human Marfan aorta and was transcriptionally overexpressed in VSMC. Fbn1 C1039G/+ -Nox4 -/- mice aortas showed a reduction of fragmented elastic fibers, which was accompanied by an amelioration in the Marfan-associated enlargement of the aortic root. Increase in the contractile phenotype marker calponin in the tunica media of MFS mice aortas was abrogated in Fbn1 C1039G/+ -Nox4 -/- mice. Endothelial dysfunction evaluated by myography in the Marfan ascending aorta was prevented by the absence of Nox4 or catalase-induced H 2 O 2 decomposition. We conclude that redox stress occurs in MFS, whose targets are actin-based cytoskeleton members and regulators of extracellular matrix homeostasis. Likewise, NOX4 have an impact in the progression of the aortic dilation in MFS and in the structural organization of the aortic tunica media, the VSMC phenotypic modulation, and endothelial function. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Ectopic pancreas with pseudocyst and pseudoaneurysm formation

    International Nuclear Information System (INIS)

    Surov, A.; Hainz, M.; Hinz, L.; Holzhausen, H.-J.; Finke, R.; Spielmann, R.-P.; Kunze, C.

    2009-01-01

    Ectopic pancreas is a rare congenital anomaly. It is usually asymptomatic, or presents with non specific gastrointestinal symptoms. We describe here a case of ectopic pancreas in the gastric antrum, with pseudocyst and pseudoaneurysm formation. This entity has not been reported previously in the literature.

  18. Low rate of reoperations after acute type A aortic dissection repair from The Nordic Consortium Registry

    DEFF Research Database (Denmark)

    Pan, Emily; Gudbjartsson, Tomas; Ahlsson, Anders

    2018-01-01

    Bakey classification nor the extent of proximal or distal repair predicted freedom from a later reoperation. The only independent risk factor associated with a later proximal reoperation was a history of connective tissue disease. CONCLUSIONS: Type A aortic dissection repair in low- to medium-volume centers......OBJECTIVES: To describe the relationship between the extent of primary aortic repair and the incidence of reoperations after surgery for type A aortic dissection. METHODS: A retrospective cohort of 1159 patients treated for type A aortic dissection at eight Nordic low- to medium......-sized cardiothoracic centers from 2005 to 2014. Data were gathered from patient records and national registries. Patients were separately divided into 3 groups according to the distal anastomoses technique (ascending aorta [n = 791], hemiarch [n = 247], and total arch [n = 66]), and into 2 groups for proximal repair...

  19. Spontaneous healing of cervical pseudoaneurysm in vertebral artery dissection under anticoagulant therapy

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, A.; Neff, W.; Schwartz, A. [Department of Neurology, Klinikum Mannheim, Medical Faculty, University of Heidelberg, Theodor-Kutzer-Ufer 1, D-68132 Mannheim (Germany)

    1998-04-01

    We report a 41-year-old woman with embolic stroke of the mid-pons attributed to embolism from vertebral artery dissection. Angiography revealed an occluded artery on one side and an incidental pseudoaneurysm of the midcervical portion of the vertebral artery on the other. After 3 months of warfarin therapy control angiography showed complete occlusion of the pseudoaneurysm. We discuss therapeutic choices and review the literature. (orig.) With 4 figs., 8 refs.

  20. In vitro characterization of bicuspid aortic valve hemodynamics using particle image velocimetry.

    Science.gov (United States)

    Saikrishnan, Neelakantan; Yap, Choon-Hwai; Milligan, Nicole C; Vasilyev, Nikolay V; Yoganathan, Ajit P

    2012-08-01

    The congenital bicuspid aortic valve (BAV) is associated with increased leaflet calcification, ascending aortic dilatation, aortic stenosis (AS) and regurgitation (AR). Although underlying genetic factors have been primarily implicated for these complications, the altered mechanical environment of BAVs could potentially accelerate these pathologies. The objective of the current study is to characterize BAV hemodynamics in an in vitro system. Two BAV models of varying stenosis and jet eccentricity and a trileaflet AV (TAV) were constructed from excised porcine AVs. Particle Image Velocimetry (PIV) experiments were conducted at physiological flow and pressure conditions to characterize fluid velocity fields in the aorta and sinus regions, and ensemble averaged Reynolds shear stress and 2D turbulent kinetic energy were calculated for all models. The dynamics of the BAV and TAV models matched the characteristics of these valves which are observed clinically. The eccentric and stenotic BAV showed the strongest systolic jet (V = 4.2 m/s), which impinged on the aortic wall on the non-fused leaflet side, causing a strong vortex in the non-fused leaflet sinus. The magnitudes of TKE and Reynolds stresses in both BAV models were almost twice as large as comparable values for TAV, and these maximum values were primarily concentrated around the central jet through the valve orifice. The in vitro model described here enables detailed characterization of BAV flow characteristics, which is currently challenging in clinical practice. This model can prove to be useful in studying the effects of altered BAV geometry on fluid dynamics in the valve and ascending aorta. These altered flows can be potentially linked to increased calcific responses from the valve endothelium in stenotic and eccentric BAVs, independent of concomitant genetic factors.

  1. Aortic stenosis with abnormal eccentric left ventricular remodeling secondary to hypothyroidism in a Bourdeaux Mastiff

    Directory of Open Access Journals (Sweden)

    Guilherme Augusto Minozzo

    Full Text Available ABSTRACT: This paper describes a case of congenital aortic stenosis with eccentric left ventricular hypertrophy associated with hypothyroidism in a 1-year-old Bourdeaux Mastiff dog. The dog had ascites, apathy, alopecic and erythematous skin lesions in different parts of the body. A two-dimensional echocardiogram revealed aortic valve stenosis, with poststenotic dilation in the ascending aorta. The same exam showed eccentric hypertrophy and dilation of the left ventricle during systole and diastole. Aortic stenosis usually results in concentric left ventricular hypertrophy instead of eccentric hypertrophy; and therefore, this finding was very unusual. Hypothyroidism, which is uncommon in young dogs, may be incriminated as the cause of ventricular dilation, making this report even more interesting. Because hypothyroidism would only result in dilatation, the eccentric hypertrophy was attributed to pressure overload caused by aortic stenosis. Thus, cardiac alterations of this case represent a paradoxical association of both diseases.

  2. The multidetector computed tomography angiography (MDCTA) in the diagnosis of splenic artery aneurysm and pseudoaneurysm

    International Nuclear Information System (INIS)

    Saba, Luca; Mallarini, Giorgio; Anzidei, Michele; Lucatelli, Pierleone

    2011-01-01

    Splenic artery aneurysm is the most frequent visceral artery aneurysm and rupture of the aneurysm is associated with a high mortality rate. It is important to discriminate between a true aneurysm and a pseudoaneurysm that may be caused by pancreatitis, iatrogenic and postoperative causes, trauma and peptic ulcer disease. Multidetector-row CT angiography (MDCTA) allows detailed visualization of the vascular anatomy and may allow identification of aneurysms and pseudoaneurysms that affect the splenic artery. The objective of this article is to provide a review of the general characteristics of splenic artery aneurysms and pseudoaneurysms and to describe the findings of MDCTA

  3. The multidetector computed tomography angiography (MDCTA) in the diagnosis of splenic artery aneurysm and pseudoaneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Saba, Luca; Mallarini, Giorgio (Dept. of Radiology, Azienda Ospedaliero Universitaria (AOU), Cagliari (Italy)), email: lucasaba@tiscali.it; Anzidei, Michele; Lucatelli, Pierleone (Dept. of Radiological Sciences, Univ. of Rome La Sapienza, Rome (Italy))

    2011-06-15

    Splenic artery aneurysm is the most frequent visceral artery aneurysm and rupture of the aneurysm is associated with a high mortality rate. It is important to discriminate between a true aneurysm and a pseudoaneurysm that may be caused by pancreatitis, iatrogenic and postoperative causes, trauma and peptic ulcer disease. Multidetector-row CT angiography (MDCTA) allows detailed visualization of the vascular anatomy and may allow identification of aneurysms and pseudoaneurysms that affect the splenic artery. The objective of this article is to provide a review of the general characteristics of splenic artery aneurysms and pseudoaneurysms and to describe the findings of MDCTA

  4. Endovascular Treatment of a Giant Superior Mesenteric Artery Pseudoaneurysm Using a Nitinol Stent-Graft

    International Nuclear Information System (INIS)

    Gandini, Roberto; Pipitone, Vincenzo; Konda, Daniel; Pendenza, Gianluca; Spinelli, Alessio; Stefanini, Matteo; Simonetti, Giovanni

    2005-01-01

    A 68-year-old woman presenting with gastrointestinal bleeding (hematocrit 19.3%) and in a critical clinical condition (American Society of Anesthesiologists grade 4) from a giant superior mesenteric artery pseudoaneurysm (196.0 x 131.4 mm) underwent emergency endovascular treatment. The arterial tear supplying the pseudoaneurysm was excluded using a 5.0 mm diameter and 31 mm long monorail expanded polytetrafluoroethylene (ePTFE)-covered self-expanding nitinol stent. Within 6 days of the procedure, a gradual increase in hemoglobin levels and a prompt improvement in the clinical condition were observed. Multislice CT angiograms performed immediately, 5 days, 30 days and 3 months after the procedure confirmed the complete exclusion of the pseudoaneurysm

  5. A Pseudoaneurysm of the Deep Palmar Arch After Penetrating Trauma to the Hand: Successful Exclusion by Ultrasound Guided Percutaneous Thrombin Injection

    Directory of Open Access Journals (Sweden)

    A. Bosman

    Full Text Available : Introduction: Pseudoaneurysm of the hand is a rare condition; most are treated surgically. Ultrasound guided thrombin injection has not previously been reported as a treatment option for pseudoaneurysms of the deep palmar arch. Report: A man was referred to the emergency department with a swollen, painful hand after penetrating trauma. On physical examination, a pulsating tumor was found on the dorsum of the hand. Imaging revealed a pseudoaneurysm vascularized by the deep palmar arch. Ultrasound guided percutaneous thrombin injection was successfully performed. Conclusion: Thrombin injection might be a safe alternative option in the treatment of pseudoaneurysm of the deep palmar arch. Keywords: Deep palmar arch, Pseudoaneurysm, Thrombin injection

  6. Transcatheter arterial embolization of a pseudoaneurysm of gastroduodenal artery: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Han, Young Min; Kang, Sung Soo; Lee, Jeong Min; Chung, Jin Young; Lee, Sang Yong; Chung, Gyung Ho; Kim, Chong Soo; Sohn, Myung Hee; Choi, Ki Chul [Chonbuk National University School of Medicine, Chonju (Korea, Republic of)

    1997-01-01

    Gastroduodenal artery pseudoaneurysm is a relatively rare and potentionally life-threatening complication of chronic pancreatitis, which is thought to occur because of autodigestion of arterial walls by pancreatic enzymes. Embolotherapy should probably be the first method of treatment, since surgical treatment carries a high risk of mortality and morbidity. We report the case of 30-year-old male with gastroduodenal artery pseudoaneurysm caused by chronic pancreatitis which was successfully treated by transcatheter embolization using Gianturco spring coils.

  7. Transcatheter arterial embolization of a pseudoaneurysm of gastroduodenal artery: a case report

    International Nuclear Information System (INIS)

    Han, Young Min; Kang, Sung Soo; Lee, Jeong Min; Chung, Jin Young; Lee, Sang Yong; Chung, Gyung Ho; Kim, Chong Soo; Sohn, Myung Hee; Choi, Ki Chul

    1997-01-01

    Gastroduodenal artery pseudoaneurysm is a relatively rare and potentionally life-threatening complication of chronic pancreatitis, which is thought to occur because of autodigestion of arterial walls by pancreatic enzymes. Embolotherapy should probably be the first method of treatment, since surgical treatment carries a high risk of mortality and morbidity. We report the case of 30-year-old male with gastroduodenal artery pseudoaneurysm caused by chronic pancreatitis which was successfully treated by transcatheter embolization using Gianturco spring coils

  8. Endovascular Treatment of a Gastroduodenal Artery Pseudoaneurysm Rupture after a Car Accident

    Directory of Open Access Journals (Sweden)

    Sofia Dutra

    2017-09-01

    Full Text Available The authors present a case of a 39-year-old man with alcoholic chronic pancreatitis that was admitted in the emergency department after a car accident, complaining of abdominal pain and looking pale. The patient was hemodinamically unstable, requiring blood transfusions. He underwent computed tomography angiogram of the abdomen and pelvis, showing a pseudoaneurysm of the gastroduodenal artery and a hemoperitoneum. He was referred to our interventional radiology unit and submitted to endovascular treatment, consisting of ‘backdoor’ and ‘frontdoor’ embolization of the gastroduodenal artery and pseudoaneurysm neck with coils, with total exclusion in control angiography. With this case description we intend to highlight the rarity of the pseudoaneurysm rupture of the gastroduodenal artery and to emphasize the importance of an interventional radiology response that had a fundamental role in the endovascular treatment, in an emergency context.

  9. Incidence and predictors of post-catheterization femoral artery pseudoaneurysms

    Directory of Open Access Journals (Sweden)

    Hussein Heshmat Kassem

    2013-09-01

    Conclusion: Femoral artery pseudoaneurysms are not uncommon. Female gender, obesity, hypertension, the use of antiplatelet and/or anticoagulant therapy and faulty puncture techniques are independent risk factors for FAPs.

  10. Endovascular management of pancreatitis-related pseudoaneurysms: A review of techniques.

    Directory of Open Access Journals (Sweden)

    Bartosz Zabicki

    Full Text Available To present the various techniques used in the management of pancreatitis-related pseudoaneurysms of visceral vessels.The retrospective clinical study was carried out at the Department of Diagnostic and Interventional Radiology at Poznan University of Medical Sciences from 2011 to 2016. The fifteen patients included in the study were diagnosed with pseudoaneurysms of visceral arteries, as a complication of chronic pancreatitis. The diagnosis was made using contrast-enhanced computed tomography, followed by angiography. On admission, all patients were symptomatic, with varying degrees of abdominal pain. One patient was haemodynamically unstable. Treatments with endovascular techniques were analysed, along with their efficacy and outcomes. Coil embolisation was performed in 5 patients. Stent graft was used in 1 patient. Liquid embolic agents were used in 7 cases, of which 5 patients were treated with thrombin injection and 2 with Squid. A combination of techniques was used in 2 patients.The most common artery affected by pseudoaneurysm formation was the splenic artery (7/15; 46.7%, and the size of the pseudoaneurysms ranged from 27 mm to 85 mm. Primary technical success was achieved in 14 out of 15 patients (93.3%. One patient required reintervention. Two patients required splenectomy after embolisation due to splenic ischemia. No recanalisation was present at the follow-up computed tomography performed after 1 to 3 weeks, and no mortality was observed within 30 days.Vascular complications of pancreatitis require accurate diagnosis and immediate treatment. Endovascular intervention is highly effective and is the preferred treatment option. The technique used is determined based on vascular anatomy and the patient's haemodynamic status.

  11. Ultrasound-Guided Glue Injection as Alternative Treatment of Femoral Pseudoaneurysms

    International Nuclear Information System (INIS)

    Aytekin, Cueneyt; Firat, Ali; Yildirim, Erkan; Kirbas, Ismail; Boyvat, Fatih

    2004-01-01

    The interventional angiographic techniques using the percutaneous femoral approach for endovascular revascularization are becoming increasingly more popular. These methods usually require larger sheaths, and most patients need postprocedural anticoagulation or antiplatelet therapy. As a consequence, the interventional procedure is associated with a higher rate of complications at the arterial entry site compared to diagnostic angiography. The reported incidence of iatrogenic pseudoaneurysm formation after coronary artery interventions ranges from 3.2% to 7.7%, and the rates noted after diagnostic angiography range from 0.2% to 1%. Peripheral pseudoaneurysms have traditionally been treated by surgical intervention, but nonsurgical alternatives, such as ultrasound (US)-guided compression, coil embolization, stent-graft placement, and percutaneous thrombin injection with or without balloon occlusion have also been documented. Of these alternatives, direct percutaneous embolization with embolic agents is the most popular method. The tissue adhesive n-butyl cyanoacrylate (NBCA) (Hystoacryl) (B. Braun, Melsungen, Germany) is one of the most popular occluding agents for neurovascular interventions, and has been widely used for more than 20 years [5,6]. In this study, we evaluated the efficacy and utility of direct percutaneous injection of NBCA for embolization of femoral pseudoaneurysms

  12. Odontogenic Pain as the Principal Presentation of Vertebral Artery Pseudoaneurysm; a Case Report

    Directory of Open Access Journals (Sweden)

    Marco Zenteno

    2015-07-01

    Full Text Available Dissection of the vertebral artery is an important but rare cause of cerebrovascular accidents. Here we report a 48-year-old man with toothache since 4 days before who presented to the emergency department with neck pain and final diagnosis of dissecting right vertebral artery pseudoaneurysm. To our knowledge, this maybe the first report of odontogenic pain as the first manifestation of vertebral artery pseudoaneurysm in the literatures.

  13. Intercostal artery pseudoaneurysm complicating corrosive acid poisoning: Diagnosis with CT and treatment with transarterial embolisation

    Directory of Open Access Journals (Sweden)

    M V Chalapathi Rao

    2014-01-01

    Full Text Available Pseudoaneurysms of intercostal artery are very rare. All the published cases have been caused by trauma, either iatrogenic or otherwise. They can cause hemothorax, retroperitoneal hemorrhage or can present as pulsatile chest mass. Doppler ultrasound, contrast-enhanced CT and conventional angiogram can accurately diagnose this condition. All the reported cases have been treated by embolisation, stenting or surgery. We report an unusual case of intercostal artery pseudoaneurysm arising as a complication of corrosive poisoning presenting with hematemesis and treated by glue embolisation. The authors believe this to be the first case of intercostal artery pseudoaneurysm that is non-traumatic, complicating corrosive poisoning and presenting with hematemesis.

  14. Diagnostic evaluation and aggressive surgical approach in bleeding pseudoaneurysms associated with pancreatic pseudocysts

    International Nuclear Information System (INIS)

    Pitkaeranta, P.; Haapiainen, R.; Kivisaari, L.; Schroeder, T.

    1991-01-01

    Hemorrhage is an uncommon but serious complication of pancreatic pseudocysts. When gastrointestinal bleeding or intra-abdominal hemorrhage is associated with a pancreatic pseudocysts and the usual sources of bleeding are not detected by endoscopy, the rupture of a pseudoaneurysm inside the pseudocyst should be suspected. The article present 13 cases, 11 associated with chronic and 2 with late complications after acute necrotizing pancreatitis. On the basis of sonographic findings, bleeding site was suspected in 8 of 11 patients. Computed tomography (CT) was performed on 10, and bleeding was suspected in 8. The pseudoaneurysm itself was detected by CT in one and by ultrasonography in none. Visceral angiography was performed on five patients, and the pseudoaneurysm was evident in all. External drainage with arterial ligation was done as a primary operation in five patients; four of them later underwent pancreatic resection because of rebleeding. In eight cases pancreatic resection was the initial operation; none of these patients continued to bleed or needed reoperation because of the same pseudoaneurysm. There were no intraoperative deaths, but one patient died postoperatively. Aggressive diagnostic evaluation and surgical approach are associated with a reduction in mortality and morbidity in this serious complication of pancreatic pseudocysts. 28 refs., 2 figs., 1 tab

  15. Measurement of the aortic diameter in the asymptomatic Korean population: Assessment with multidetector CT

    International Nuclear Information System (INIS)

    Lee, Sang Hwan; Lee, Whal; Choi, Hyuck Jae; Kim, Dae Jin; Park, Eun Ah; Chung, Jin Wook; Park, Jae Hyung

    2013-01-01

    To determine normal reference values for aortic diameters in asymptomatic Korean adults. Three hundred adults without signs or symptoms of cardiovascular diseases were enrolled in this study. Aortic diameters were measured at nine predetermined levels on CT images. Aortic diameter measurements were adjusted for body surface area. Analysis of data was performed with regard to age, sex, weight, height and hypertension. Aortic diameters were 2.99 ± 0.57 cm at the ascending aorta, 2.54 ± 0.35 cm at the transverse aortic arch, 2.36 ± 0.35 cm at the proximal descending thoracic aorta (DTA), 2.23 ± 0.37 cm at the mid DTA, 2.17 ± 0.38 cm at the distal DTA, 2.16 ± 0.37 cm at the thoracoabdominal junction, 2.10, 00B1, 0.35 cm at the level of the celiac axis, 1.94, 00B1, 0.36 cm at the suprarenal aorta, 1.58 ± 0.24 cm at the aortic bifurcation. Men had slightly larger diameters than women (p < 0.05). All diameters increased with age and hypertension, with statistical significance (p < 0.01). And all aortic diameters increased with height (p < 0.05) except at the level of the aortic arch (p = 0.056), and increased with weight (p < 0.05) except at the level of the suprarenal aorta (p = 0.067). Male sex, higher weight and height, age and hypertension are associated with larger aortic diameters in asymptomatic Korean adults.

  16. Impact of aortic root size on left ventricular afterload and stroke volume.

    Science.gov (United States)

    Sahlén, Anders; Hamid, Nadira; Amanullah, Mohammed Rizwan; Fam, Jiang Ming; Yeo, Khung Keong; Lau, Yee How; Lam, Carolyn S P; Ding, Zee Pin

    2016-07-01

    The left ventricle (LV) ejects blood into the proximal aorta. Age and hypertension are associated with stiffening and dilation of the aortic root, typically viewed as indicative of adverse remodeling. Based on analytical considerations, we hypothesized that a larger aortic root should be associated with lower global afterload (effective arterial elastance, EA) and larger stroke volume (SV). Moreover, as antihypertensive drugs differ in their effect on central blood pressure, we examined the role of antihypertensive drugs for the relation between aortic root size and afterload. We studied a large group of patients (n = 1250; 61 ± 12 years; 78 % males; 64 % hypertensives) from a single-center registry with known or suspected coronary artery disease. Aortic root size was measured by echocardiography as the diameter of the tubular portion of the ascending aorta. LV outflow tract Doppler was used to record SV. In the population as a whole, after adjusting for key covariates in separate regression models, aortic root size was an independent determinant of both SV and EA. This association was found to be heterogeneous and stronger in patients taking a calcium channel blocker (CCB; 10.6 % of entire population; aortic root size accounted for 8 % of the explained variance of EA). Larger aortic root size is an independent determinant of EA and SV. This association was heterogeneous and stronger in patients on CCB therapy.

  17. Transcatheter Arterial Embolization of Cystic Artery Pseudoaneurysm in Acalculous Cholecystitis: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyung Ook; Lee, Young Hwan [Dept. of Radiology, Daegu Catholic University College of Medicine, Daegu (Korea, Republic of); Kim, Young Hwan [Dept. of Diagnostic Radiology, Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of)

    2011-04-15

    A pseudoaneurysm of the cystic artery is a rare complication of cholecystitis, and is manifested by hemobilia or hematemesis. An early diagnosis is required for the successful treatment by cholecystectomy and ligation of the cystic artery. Herein, we report a case of a pseudoaneurysm of the cystic artery diagnosed by color Doppler ultrasonography and CT, and successfully treated by transcatheter arterial embolization with N-butyl cyanoacrylate in a high-risk surgical patient.

  18. Recurrent life-threatening haemoptysis from a bleeding vertebral artery pseudoaneurysm: A diagnostic dilemma.

    Science.gov (United States)

    Chandran, Arun; Biswas, Shubhabrata; Hartley, James Leon; Nahser, Hans Christean; Lancaster, Jeffrey; Puthuran, Mani

    2016-10-01

    A bleeding vertebral artery pseudoaneurysm is a rare cause of haemoptysis. Pseudoaneurysm can arise due to radionecrosis from previous radiotherapy in the base of skull and neck region and may present with haemoptysis many years later. It is important to be aware of this entity in the work-up of haemoptysis, particularly in patients with previous base of skull and neck radiotherapy. Our patient was successfully treated with endovascular occlusion. © The Author(s) 2016.

  19. Pseudoaneurysm embolization and vasopressin infusion for lower gastrointestinal bleeding due to recurrence of urinary bladder carcinoma.

    Science.gov (United States)

    Kakizawa, Hideaki; Toyota, Naoyuki; Mita, Koji; Fujimura, Yoshio; Hieda, Masashi; Hirai, Nobuhiko; Tachikake, Toshihiro; Ito, Katsuhide

    2006-05-01

    We report a case that was successfully treated for massive lower gastrointestinal (LGI) bleeding due to a recurrent urinary bladder carcinoma. Treatment consisted of combination therapy including embolization of an inferior gluteal artery (IGA) pseudoaneurysm and low-dose arterial vasopressin infusion via a sigmoid artery (SA). A 57-year-old man presented with life-threatening sudden, massive LGI bleeding due to an obturator lymph node (LN) metastasis from a urinary bladder carcinoma. Computed tomography showed that the LN recurrence had invaded all the way to the sigmoid colon, and there was a pseudoaneurysm with extravasation inside the recurrence. An angiogram revealed a left IGA pseudoaneurysm. We therefore excluded the pseudoaneurysm by embolization with microcoils. Following this treatment the bleeding decreased, but intermittent LGI bleeding continued. Endoscopic examination showed the tumor with a huge ulcer inside the colonic lumen, and continuous oozing was confirmed. A second angiogram showed no recurrence of the IGA pseudoaneurysm and no apparent findings of bleeding. Then a 3F microcatheter was placed in the SA selectively using a coaxial catheter system, and vasopressin was infused at a rate 0.05 U/min for 12 h. Bleeding completely ceased 2 days later. There were no signs of ischemic gastrointestinal complications. Massive LGI bleeding has not recurred in 5 months.

  20. Treatment of traumatic internal carotid artery pseudoaneurysms with willis covered stents: a midterm follow-up result

    International Nuclear Information System (INIS)

    Wang Wu; Li Minghua; Li Yongdong; Gu Binxian; Fang Chun; Tan Huaqiao; Wang Ju; Zhang Peilei

    2010-01-01

    Objective: To evaluate the efficacy and mid-term follow-up results of endovascular treatment with Willis covered stent for traumatic pseudoaneurysms located in the internal carotid artery (ICA). Methods: ICA angiography was performed in 38 patients with traumatic brain and neck injury. Of the 38 patients, 13 delayed traumatic pseudoaneurysms were found. All the pseudoaneurysms were treated with Willis covered stents. Follow-up angiography was performed at 1, 3, 6 and 12 months after the procedure, and the results were categorized as complete or incomplete occlusion. Clinical manifestations were graded as full recovery, improvement, unchanged and aggravation. Results: Willis covered stent placement was technically successful in all traumatic pseudoaneurysms. No procedure-related complications occurred. The initial angiographic results showed a complete occlusion in 9 patients, and an incomplete occlusion in 4. The angiographic follow-up within 3-12 months exhibited a complete occlusion in 12 patients and the parent arteries remained patency in all patients. The clinical follow-up observation demonstrated that full recovery was obtained in 11 patients, clinical improvement in one, and unchanged condition in one. No morbidity or mortality occurred. Conclusion: Willis covered stent implantation is a feasible and practical treatment for traumatic pseudoaneurysms located in the ICA. This technique can well preserve the parent artery with excellent therapeutic results. (authors)

  1. Superficial Temporal Artery Pseudoaneurysm: A Conservative Approach in a Critically Ill Patient

    International Nuclear Information System (INIS)

    Grasso, Rosario Francesco; Quattrocchi, Carlo Cosimo; Crucitti, Pierfilippo; Carboni, Giampiero; Coppola, Roberto; Zobel, Bruno Beomonte

    2007-01-01

    A 71-year-old man affected by cardio- and cerebrovascular disease experienced an accidental fall and trauma to the fronto-temporal area of the head. A few weeks later a growing mass appeared on his scalp. A diagnosis of superficial temporal artery pseudoaneurysm was made following CT and color Doppler ultrasound. His clinical condition favoured a conservative approach by ultrasound-guided compression and subsequent surgical resection. A conservative approach should be considered the treatment of choice in critically ill patients affected by superficial temporal artery pseudoaneurysm

  2. Percutaneous Glue Embolization of a Visceral Artery Pseudoaneurysm in a Case of Sickle Cell Anemia

    International Nuclear Information System (INIS)

    Gulati, Gurpreet S.; Gulati, Manpreet S.; Makharia, Govind; Hatimota, Pradeep; Saikia, Nripen; Paul, Shashi B.; Acharya, Subrat

    2006-01-01

    Although aneurysmal complications of sickle cell anemia have been described in the intracranial circulation, visceral artery pseudoaneurysms in this disease entity have not previously been reported in the literature. Conventional treatment of visceral pseudoaneurysms has been surgical ligation or resection of the aneurysm. Transcatheter embolization has emerged as an attractive, minimally invasive alternative to surgery in the treatment of these lesions. In certain situations, however, due to the unfavorable angiographic anatomy precluding safe transcatheter embolization, direct percutaneous glue injection of the pseudoaneurysm sac may be considered to achieve successful occlusion of the sac. The procedure may be rendered safer by simultaneous balloon protection of the parent artery. We describe this novel treatment modality in a case of inferior pancreaticoduodenal artery pseudoaneurysm in a patient with sickle cell anemia. Although a complication in the form of glue reflux into the parent vessel occurred that necessitated surgery, this treatment modality may be used in very selected cases (where conventional endovascular embolization techniques are not applicable) after careful selection of the balloon diameter and appropriate concentration of the glue-lipiodol mixture

  3. Rupture of an internal carotid artery pseudoaneurysm after irradiation for a nasopharyngeal carcinoma. Case report

    International Nuclear Information System (INIS)

    Hanada, Yukiko; Nakamura, Megumi; Sasai, Hisanori; Kamakura, Aya; Sakata, Yoshiharu; Miyahara, Hiroshi

    2013-01-01

    The primary treatment of nasopharyngeal carcinoma (NPC) has been external radiotherapy. Rupture of an internal carotid artery (ICA) pseudoaneurysm is a rare complication of irradiation therapy for a nasopharyngeal carcinoma. A 78 years old man had a history of NPC treated with radiotherapy in 1993. He was admitted to the hospital because of epistaxis. Angiography showed an ICA pseudoaneurysm pointing medially to the nasopharynx. Coil embolization of the ICA was performed, but cerebral infarction occurred. Internal carotid artery (ICA) pseudoaneurysms are an uncommon but potentially lethal condition. Angiography is the mainstay of diagnosis of the aneurysm and planning the embolization of the ICA. We should be more aware of this complication in NPC patients. (author)

  4. Valve-sparing aortic root reconstruction in children, teenagers, and young adults.

    Science.gov (United States)

    Tweddell, James S; Earing, Michael G; Bartz, Peter J; Dunham-Ingles, Jennifer L; Woods, Ronald K; Mitchell, Michael E

    2012-08-01

    We reviewed our experience with valve-sparing aortic root reconstruction (VSARR) using the sinus of Valsalva graft in children, teenagers, and young adults with connective tissue disorders. Results of a single-center experience with VSARR in children, teenagers, and young adults were retrospectively analyzed. End points were death, freedom from reintervention, and freedom from valve dysfunction. Between 2003 and 2010, 16 patients (Marfan, 9; Loeys Dietz syndrome, 6; conotruncal, 1) underwent VSARR. The mean age was 20±7.4 (range, 9 to 36 years). Indications for VSAAR were aortic root enlargement in 14 (sinus of Valsalva Z-score, 6.2±2) and aortic dissection in 2. Additional procedures included replacement of the ascending aorta in 7, with additional replacement of the aortic arch in 2. No early or late deaths occurred. One patient required a pacemaker. One patient with Loeys-Dietz syndrome required reoperation for aneurysmal dilatation of the coronary buttons. Two patients underwent replacement of the thoracoabdominal aorta for chronic dissection. Follow-up by echocardiography or magnetic resonance imaging at a mean of 33±29 months showed more than mild aortic regurgitation in 2 patients. Both patients with moderate aortic insufficiency also had a bicuspid aortic valve. VSARR using the sinus of Valsalva graft is a reproducible technique that achieves acceptable early and intermediate results. It is suitable for children, teenagers, and young adults. Anticoagulation is avoided. The procedure is appropriate for emergency operations but should be used with caution in patients with a bicuspid aortic valve. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Use of a Stent Graft for Bleeding Hepatic Artery Pseudoaneurysm Following Pancreaticoduodenectomy

    Directory of Open Access Journals (Sweden)

    Leoncio L. Kaw, Jr

    2006-10-01

    Full Text Available Although uncommon, bleeding following pancreaticoduodenectomy is associated with high mortality. Management generally includes surgical reexploration or, alternatively, transarterial embolization. We report the case of a 62-year-old man who presented with massive upper gastrointestinal bleeding 3 weeks after pancreaticoduodenectomy. Selective coeliac angiography revealed a large pseudoaneurysm involving the proper hepatic artery. This was treated successfully with a stent graft. There was no recurrence of bleeding at the 6-month follow-up. To our knowledge, this is the first report of stent graft repair of bleeding hepatic artery pseudoaneurysm following pancreaticoduodenectomy.

  6. Aortic microcalcification is associated with elastin fragmentation in Marfan syndrome.

    Science.gov (United States)

    Wanga, Shaynah; Hibender, Stijntje; Ridwan, Yanto; van Roomen, Cindy; Vos, Mariska; van der Made, Ingeborg; van Vliet, Nicole; Franken, Romy; van Riel, Luigi Amjg; Groenink, Maarten; Zwinderman, Aeilko H; Mulder, Barbara Jm; de Vries, Carlie Jm; Essers, Jeroen; de Waard, Vivian

    2017-11-01

    Marfan syndrome (MFS) is a connective tissue disorder in which aortic rupture is the major cause of death. MFS patients with an aortic diameter below the advised limit for prophylactic surgery (elastin fragments play a causal role in aortic calcification in MFS, and that microcalcification serves as a marker for aortic disease severity. To address this hypothesis, we analysed MFS patient and mouse aortas. MFS patient aortic tissue showed enhanced microcalcification in areas with extensive elastic lamina fragmentation in the media. A causal relationship between medial injury and microcalcification was revealed by studies in vascular smooth muscle cells (SMCs); elastin peptides were shown to increase the activity of the calcification marker alkaline phosphatase (ALP) and reduce the expression of the calcification inhibitor matrix GLA protein in human SMCs. In murine Fbn1 C1039G/+ MFS aortic SMCs, Alpl mRNA and activity were upregulated as compared with wild-type SMCs. The elastin peptide-induced ALP activity was prevented by incubation with lactose or a neuraminidase inhibitor, which inhibit the elastin receptor complex, and a mitogen-activated protein kinase kinase-1/2 inhibitor, indicating downstream involvement of extracellular signal-regulated kinase-1/2 (ERK1/2) phosphorylation. Histological analyses in MFS mice revealed macrocalcification in the aortic root, whereas the ascending aorta contained microcalcification, as identified with the near-infrared fluorescent bisphosphonate probe OsteoSense-800. Significantly, microcalcification correlated strongly with aortic diameter, distensibility, elastin breaks, and phosphorylated ERK1/2. In conclusion, microcalcification co-localizes with aortic elastin degradation in MFS aortas of humans and mice, where elastin-derived peptides induce a calcification process in SMCs via the elastin receptor complex and ERK1/2 activation. We propose microcalcification as a novel imaging marker to monitor local elastin degradation and

  7. Early outcome of mini aortic valve replacement surgery

    Directory of Open Access Journals (Sweden)

    Shawky Fareed

    2018-03-01

    Full Text Available Background: Minimally invasive aortic valve surgery (MIAVS has evolved into a well-tolerated, efficient surgical treatment option in experienced centers, providing greater patient satisfaction and lower complication rates. Potential advantages of MIAVR arise from the concept that patient morbidity and potential mortality could be reduced without compromising the excellent results of the conventional procedure which include improved cosmetic results, safer access in the case of reoperation, less postoperative bleeding, lower intensive care unit (ICU and in-hospital stays, as well as the absence of sternal wound infection. These results were achievable also in high-risk patients. Reduced pain and hospital length of stay, decreased time until return to full activity and decreased blood product use have also been demonstrated. Methods: Sixty patients with aortic valve disease randomized into two equal groups; group “A” underwent aortic valve surgery through a minimally invasive limited upper sternotomy. Group “B” underwent aortic valve surgery through a full median sternotomy. The Pain was evaluated on 2nd, 3rd day post-operatively and at the 3rd, 6th month after discharge. Echocardiographic data were performed preoperatively and at the 3rd, 6th month after discharge in all patients. Standard aortic and bicaval cannulation with cold antegrade crystalloid cardioplegia was adopted in group“B”, while in group “A” femoral vein with ascending aortic cannulation was adopted with antegrade blood cardioplegia. Results: There was no statistical difference between the two groups preoperatively regarding their age, sex, NYHA class, EF%, LA dimension, spirometric study. There was no operative mortality in both groups but few postoperative complications occurred in both groups. Total hospital stay, ICU stay, postoperative bleeding, inotropic requirement, ventilatory support, blood transfusion was less in group “A”, with better cosmetic

  8. Successful treatment of coronary artery pseudoaneurysm by graft stent, which developed after the implantation of bare metal stent

    Directory of Open Access Journals (Sweden)

    Utku Şenol

    2013-03-01

    Full Text Available Although coronary artery pseudoaneurysm which couldoccur following percutaneous coronary interventions is arare complication, it can be mortal. As soon as the pseudoaneurysmis diagnosed, it should be treated by percutaneousintervention or surgery. Graft stent implantationis a preferred treatment for appropriate patients. In thiscase report, we presented a successful treatment of coronaryartery pseudoaneurysm by graft stent; which developedafter the implantation of bare metal stent into theleft anterior descending coronary artery. J Clin Exp Invest2013; 4 (1: 126-129Key words: Coronary artery, pseudoaneurysm, graft stent

  9. Iatrogenic femoral artery pseudoaneurysms - A review of current methods of diagnosis and treatment

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, F. [Department of Interventional Radiology, Royal Berkshire NHS Foundation Trust, Reading (United Kingdom)], E-mail: farhan@doctors.org.uk; Turner, S.A.; Torrie, P.; Gibson, M. [Department of Interventional Radiology, Royal Berkshire NHS Foundation Trust, Reading (United Kingdom)

    2008-12-15

    The common femoral artery is commonly used as arterial access for a wide range of radiological and cardiological procedures. Pseudoaneurysm formation is the most common arterial complication of femoral artery catheterization, and is diagnosed using colour Doppler ultrasound. Ultrasound-guided thrombin injection has replaced ultrasound-guided compression as the first-line treatment. The practicalities of thrombin injection (technique and types of thrombin available) and other treatment options are discussed. Awareness of pseudoaneurysm formation and the treatment options allows prompt diagnosis and successful treatment.

  10. Pseudoaneurysm of the facial artery following bilateral temporomandibular joint replacement: A case report

    Directory of Open Access Journals (Sweden)

    Lanit Anand

    2017-03-01

    Case report: A 59-year-old male presented to our department with bony ankylosis of his temporomandibular joints bilaterally as a result of previous osteomyelitis. He underwent bilateral temperomandibular joint replacements in a two-stage procedure. Six weeks post discharge he presented to the emergency department in haemorrhagic shock, having lost significant blood volume from a pulsatile lesion over his right mandible. Computed tomography angiography revealed a pseudoaneurysm of the right facial artery. He proceeded to emergent embolisation with resolution of the pseudoaneurysm.

  11. Iatrogenic femoral artery pseudoaneurysms - A review of current methods of diagnosis and treatment

    International Nuclear Information System (INIS)

    Ahmad, F.; Turner, S.A.; Torrie, P.; Gibson, M.

    2008-01-01

    The common femoral artery is commonly used as arterial access for a wide range of radiological and cardiological procedures. Pseudoaneurysm formation is the most common arterial complication of femoral artery catheterization, and is diagnosed using colour Doppler ultrasound. Ultrasound-guided thrombin injection has replaced ultrasound-guided compression as the first-line treatment. The practicalities of thrombin injection (technique and types of thrombin available) and other treatment options are discussed. Awareness of pseudoaneurysm formation and the treatment options allows prompt diagnosis and successful treatment

  12. Stent-Graft Repair of a Large Cervical Internal Carotid Artery Pseudoaneurysm Causing Dysphagia

    International Nuclear Information System (INIS)

    Gupta, Vivek; Niranjan, Khandelwal; Rawat, Lokesh; Gupta, A. K.

    2009-01-01

    Pseudoaneurysms of the cervical internal carotid artery (ICA) are rare and most frequently result from trauma, infection, or sometimes spontaneously. They have the potential to cause life-threatening hemorrhage; thus, their immediate management is necessary. Endovascular treatment by stent graft placement in the affected artery appears to be a safe and effective treatment option. We present a case of a child who presented with neck swelling and dysphagia caused by a ruptured cervical ICA pseudoaneurysm which was managed by stent graft placement.

  13. Transcatheter embolization of celiac artery pseudoaneurysm following pancreatico-duodenectomy for pancreatic cancer. A case report

    International Nuclear Information System (INIS)

    Mori, K.; Yoshioka, H.; Kuramochi, M.; Saida, Y.; Itai, Y.; Murata, S.; Michishita, N.; Oda, T.

    1998-01-01

    A case of transcatheter embolization of a celiac artery pseudoaneurysm in a 70-year-old man is reported. The pseudoaneurysm was considered to be the result of pancreatic anastomotic leakage and an intra-abdominal abscess following pancreaticoduodenectomy with irradiation of 66 Gy for pancreatic carcinoma. To avoid recanalization of the pseudoaneurysm due to retrograde blood flow, first all branches of the celiac artery were embolized with metallic coils, and then the celiac trunk was also occluded. Hepatic arterial flow was preserved by the right hepatic artery arising from the superior mesenteric artery. After the procedure, the patient had no noticeable complications associated with the embolization nor any recurrence of the pancreatic cancer, and he achieved a 2-year survival. (orig.)

  14. Transcatheter embolization of celiac artery pseudoaneurysm following pancreatico-duodenectomy for pancreatic cancer. A case report

    Energy Technology Data Exchange (ETDEWEB)

    Mori, K.; Yoshioka, H.; Kuramochi, M.; Saida, Y.; Itai, Y. [Dept. of Radiology, Tsukuba Univ. Hospital (Japan); Murata, S. [Dept. of Diagnostic Radiology, Univ. Hospital, Malmoe (Sweden); Michishita, N. [Dept. of Radiology, Tsuchiura Kyodo Hospital (Japan); Oda, T. [Dept. of Surgery, Tsukuba Univ. Hospital (Japan)

    1998-11-01

    A case of transcatheter embolization of a celiac artery pseudoaneurysm in a 70-year-old man is reported. The pseudoaneurysm was considered to be the result of pancreatic anastomotic leakage and an intra-abdominal abscess following pancreaticoduodenectomy with irradiation of 66 Gy for pancreatic carcinoma. To avoid recanalization of the pseudoaneurysm due to retrograde blood flow, first all branches of the celiac artery were embolized with metallic coils, and then the celiac trunk was also occluded. Hepatic arterial flow was preserved by the right hepatic artery arising from the superior mesenteric artery. After the procedure, the patient had no noticeable complications associated with the embolization nor any recurrence of the pancreatic cancer, and he achieved a 2-year survival. (orig.)

  15. A case study of an axillary artery pseudoaneurysm following anterior dislocation of the glenohumeral joint: A rare presentation on plain film radiographs

    International Nuclear Information System (INIS)

    Whittam, Katie; Hardy, Maryann

    2007-01-01

    Axillary pseudoaneurysm is a rare but important complication of anterior glenohumeral joint dislocation. Diagnosis of axillary pseudoaneurysm is predominantly undertaken following clinical examination but where diagnosis is uncertain, Doppler ultrasound is the imaging examination of choice to confirm diagnosis. In this case study, the initial clinical signs of axillary pseudoaneurysm were masked by the presenting trauma and, although findings indicative of pseudoaneurysm were present on late plain film images, they were not immediately recognised. Misdiagnosis or delayed diagnosis of axillary pseudoaneurysm may result in upper limb morbidity or patient mortality. Consequently, the prompt and accurate identification of an axillary pseudoaneurysm on plain film radiographs, although rare, is essential. Yet for inexperienced film readers, correctly identifying an axillary pseudoaneurysm can be difficult due to its apparent similarity to other pathologies. This article will highlight the differences in radiological appearances between a pseudoaneurysm and a gleno-humeral joint effusion to raise radiographer awareness of the risks and clinical signs of an axillary pseudoaneurysm post gleno-humeral joint dislocation and discuss the difficulties encountered in its diagnosis. Finally, this review will evaluate current diagnostic practices in comparison with best practice, as identified in the literature [Fitzgerald JF, Keates J. False aneurysm as a late complication of anterior shoulder dislocation. Ann Surg 1975;6:785-6; Drury JK, Scullion JE. Vascular complications of anterior dislocation of the shoulder. Br J Surg 1980;67(8):579-81. Waxman DL, France MP, Douglas T, Harryman I. Late lateral displacement of the humeral head after closed reduction of dislocation: a sign of vascular injury. J Bone Joint Surg 1996;78(6):907-10

  16. 合并有主动脉弓及升主动脉倒撕裂的DeBakeyⅢ型主动脉夹层腔内介入治疗的时机和效果%Timing of TEVAR treatment in DeBakeyⅢtype aortic dissection associated with arch and ascending aorta anti-tearing

    Institute of Scientific and Technical Information of China (English)

    王志伟; 管生; 王稼祥; 李震

    2013-01-01

    Objective To explore the timing and the efficacy of TEVAR treatment in DeBakeyⅢtype aortic dissection associated with arch and ascending aorta anti-tearing. Methods Clinical data of 10 patients with DeBakeyⅢaortic dissection associated with arch and ascending aorta anti-tearing from January 2010 to January 2013 were retrospectively analyzed. All the patients had ifnally stepped stent therapy on the basis of conservative treatment, were erplored according to the follow up results. Results One case conducted TEVAR treatment three days after admission because of poor blood pressure control, but died of sudden pericardial tamponade postoperative two days. After 4 weeks’ conservative treatment all of 9 patients were performed TEVAR, the postoperative patients recovered well and were followed up for 6 to 30 months without adverse events. Conclusions False lumen thrombosis in ascending aorta and aortic arch are stable and partially absorbed after four weeks with conservative management in the patients who have DeBakeyⅢaortic dissection with arch and ascending aorta anti-tearing, and then the aortic arch can provide a relatively stable anchoring zone in the proximal end for TEVAR.%目的:探讨主动脉腔内修复术(TEVAR)治疗合并有主动脉弓和(或)升主动脉倒撕裂的DeBakeyⅢ型主动脉夹层的手术时机及疗效。方法对2010年1月至2013年1月郑州大学第一附属医院介入科收治的10例DeBakeyⅢ型主动脉夹层、同时合并有主动脉弓和(或)升主动脉逆向撕裂患者,在保守治疗的基础上行介入覆膜支架治疗,结合随访情况,探讨对该类患者行主动脉腔内修复术(TEVAR)的可行性、治疗时机及效果。结果1例患者血压控制差,入院后第3天行TEVAR治疗,术后第2天突发心包填塞而死亡;余9例患者在保守治疗4周,CT血管造影(CTA)显示逆向撕裂假腔内血栓稳定并部分吸收后

  17. An unusual case of common carotid artery pseudoaneurysm caused ...

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    pseudoaneurysm involving the right common carotid artery. Sewing needle ( ... displacement of tracheal shadow towards the left ... CT scan of brain was not done in this case as there are no .... function and allergies to CT contrast material12.

  18. A Structural Finite Element Model for Lamellar Unit of Aortic Media Indicates Heterogeneous Stress Field After Collagen Recruitment

    Science.gov (United States)

    Thunes, James R.; Pal, Siladitya; Fortunato, Ronald N.; Phillippi, Julie A.; Gleason, Thomas G.; Vorp, David A.; Maiti, Spandan

    2016-01-01

    Incorporation of collagen structural information into the study of biomechanical behavior of ascending thoracic aortic (ATA) wall tissue should provide better insight into the pathophysiology of ATA. Structurally motivated constitutive models that include fiber dispersion and recruitment can successfully capture overall mechanical response of the arterial wall tissue. However, these models cannot examine local microarchitectural features of the collagen network, such as the effect of fiber disruptions and interaction between fibrous and non-fibrous components, which may influence emergent biomechanical properties of the tissue. Motivated by this need, we developed a finite element based three-dimensional structural model of the lamellar units of the ATA media that directly incorporates the collagen fiber microarchitecture. The fiber architecture was computer generated utilizing network features, namely fiber orientation distribution, intersection density and areal concentration, obtained from image analysis of multiphoton microscopy images taken from human aneurysmal ascending thoracic aortic media specimens with bicuspid aortic valve (BAV) phenotype. Our model reproduces the typical J-shaped constitutive response of the aortic wall tissue. We found that the stress state in the non-fibrous matrix was homogeneous until the collagen fibers were recruited, but became highly heterogeneous after that event. The degree of heterogeneity was dependent upon local network architecture with high stresses observed near disrupted fibers. The magnitude of non-fibrous matrix stress at higher stretch levels was negatively correlated with local fiber density. The localized stress concentrations, elucidated by this model, may be a factor in the degenerative changes in aneurysmal ATA tissue. PMID:27113538

  19. Endovascular Aneurysm Repair and Sealing (EVARS): A Useful Adjunct in Treating Challenging Morphology

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, Gareth J., E-mail: garethjamesharrison@yahoo.co.uk; Antoniou, George A., E-mail: antoniou.ga@hotmail.com; Torella, Francesco, E-mail: francesco.torella@rlbuht.nhs.uk; McWilliams, Richard G., E-mail: richard.mcwilliams@rlbuht.nhs.uk; Fisher, Robert K., E-mail: robert.fisher@rlbuht.nhs.uk [Royal Liverpool University Hospital, Liverpool Vascular and Endovascular Service (United Kingdom)

    2016-04-15

    An 81-year-old male with previous open abdominal aortic aneurysm repair presented with asymptomatic large pseudoaneurysms at both ends of an open surgical tube graft. Endovascular aneurysm sealing (EVAS) in combination with the iliac limbs of a standard endovascular aneurysm repair (EVAR) successfully excluded both pseudoaneurysms from circulation. We describe the combination of elements of EVAS and EVAR and have termed this endovascular aneurysm repair and sealing (EVARS). EVARS has the advantage of harnessing the benefits of endobag sealing in aortic necks unsuitable for standard EVAR whilst providing the security of accurate stent placement within short common iliac arteries. In conclusion, EVAS may be combined with standard endovascular iliac limbs and is a possible treatment option for pseudoaneurysm following open aneurysm repair.

  20. Urgent carotid stenting before cardiac surgery in a young male patient with acute ischemic stroke caused by aortic and carotid dissection

    Directory of Open Access Journals (Sweden)

    Popović Rade

    2016-01-01

    Full Text Available Introduction. Acute aortic dissection (AD is the most common life-threatening disorder affecting the aorta. Neurological symptoms are present in 17-40% of cases. The management of these patients is controversial. Case report. We presented a 37-year-old man admitted for complaining of left-sided weak-ness. Symptoms appeared two hours before admission. The patient had no headache, neither thoracic pain. Neurological examination showed mild confusion, left-sided hemiplegia, National Institutes of Health Stroke Scale (NIHSS score was 10. Ischemic stroke was suspected, brain multislice computed tomography (MSCT and angiography were performed and right intrapetrous internal carotid artery dissection noted. Subsequent color Doppler ultrasound of the carotid arteries showed dissection of the right common carotid artery (CCA. The patient underwent thoracic and abdominal MSCT aortography which showed ascending aortic dissection from the aortic root, propagating in the brachiocephalic artery and the right CCA. Digital subtraction angiography was performed subsequently and two stents were successfully implanted in the brachiocephalic artery and the right CCA prior to cardiac surgery, only 6 hours after admission. The ascending aorta was reconstructed with graft interposition and the aortic valve re-suspended. The patient was hemodynamically stable and with no neurologic deficit after surgery. Unfortinately, at the operative day 6, mediastinitis developed and after intensive treatment the patients died 35 days after admission. Conclusion. In young patients with suspected stroke and oscillatory neurological impairment urgent MSCT angiography of the brain and neck and/or Doppler sonography of the carotid and vertebral artery are mandatory to exclude carotid and aortic dissection. The prompt diagnosis permits urgent carotid stenting and cardiosurgery. To the best of our knowledge, this is the first published case of immediate carotid stenting in acute ischemic

  1. Extrahepatic Pseudoaneurysms and Ruptures of the Hepatic Artery in Liver Transplant Recipients: Endovascular Management and a New Iatrogenic Etiology

    International Nuclear Information System (INIS)

    Saad, Wael E. A.; Dasgupta, Niloy; Lippert, Allison J.; Turba, Ulku C.; Davies, Mark G.; Kumer, Sean; Gardenier, Jason C.; Sabri, Saher S.; Park, Auh-Whan; Waldman, David L.; Schmitt, Timothy; Matsumoto, Alan H.; Angle, John F.

    2013-01-01

    To characterize extrahepatic pseudoaneurysm regarding incidence and etiology and determine the effectiveness of endovascular management. A retrospective audit of 1,857 liver transplants in two institutions was performed (1996–2009). Recipients’ demographics, clinical presentation, transplant type, biliary anastomosis, and presence of biliary endoprostheses were noted. Pseudoaneurysms were classified into iatrogenic (associated with biliary endoprosthesis or angioplasty) or spontaneous extrahepatic pseudoaneurysms. Spontaneous and iatrogenic pseudoaneurysms were compared for time from transplant, presenting symptoms, location in the arterial anatomy, and 3-month graft survival. Arterial patency and 6-month graft survival were calculated. Twenty pseudoaneurysms were found (1.1 %, 20/1,857): 9 (0.5 % of transplants, 9/1,857) were spontaneous and 11 (0.6 % of transplants, 11/1,857) were “iatrogenic” (due to minimally invasive procedures: 4 angioplasty and 7 biliary endoprostheses). Sixty percent (12/20) underwent endovascular management (4 coil embolization and 8 stent-grafts). Technical success was 83 % (10/12) with a mean arterial patency of 70 % (follow-up mean, 4.9; range, 0–18 months). The 1-, 3-, and 6-month graft survival was 70, 40, and 35 %, respectively. Due to minimally invasive procedures, posttransplant extrahepatic pseudoaneurysms are no longer an exclusive complication of the transplant surgery itself. Endovascular management is effective to stabilize patients but has not improved historic postsurgical graft survival.

  2. Extrahepatic Pseudoaneurysms and Ruptures of the Hepatic Artery in Liver Transplant Recipients: Endovascular Management and a New Iatrogenic Etiology

    Energy Technology Data Exchange (ETDEWEB)

    Saad, Wael E. A., E-mail: wspikes@yahoo.com; Dasgupta, Niloy; Lippert, Allison J.; Turba, Ulku C.; Davies, Mark G. [University of Virginia Health System, Division of Vascular Interventional Radiology, Department of Radiology (United States); Kumer, Sean [University of Virginia Health System, Division of Solid Organ Transplantation, Department of Surgery (United States); Gardenier, Jason C.; Sabri, Saher S.; Park, Auh-Whan [University of Virginia Health System, Division of Vascular Interventional Radiology, Department of Radiology (United States); Waldman, David L. [University of Rochester Medical Center, Department of Imaging Sciences (United States); Schmitt, Timothy [University of Virginia Health System, Division of Solid Organ Transplantation, Department of Surgery (United States); Matsumoto, Alan H.; Angle, John F. [University of Virginia Health System, Division of Vascular Interventional Radiology, Department of Radiology (United States)

    2013-02-15

    To characterize extrahepatic pseudoaneurysm regarding incidence and etiology and determine the effectiveness of endovascular management. A retrospective audit of 1,857 liver transplants in two institutions was performed (1996-2009). Recipients' demographics, clinical presentation, transplant type, biliary anastomosis, and presence of biliary endoprostheses were noted. Pseudoaneurysms were classified into iatrogenic (associated with biliary endoprosthesis or angioplasty) or spontaneous extrahepatic pseudoaneurysms. Spontaneous and iatrogenic pseudoaneurysms were compared for time from transplant, presenting symptoms, location in the arterial anatomy, and 3-month graft survival. Arterial patency and 6-month graft survival were calculated. Twenty pseudoaneurysms were found (1.1 %, 20/1,857): 9 (0.5 % of transplants, 9/1,857) were spontaneous and 11 (0.6 % of transplants, 11/1,857) were 'iatrogenic' (due to minimally invasive procedures: 4 angioplasty and 7 biliary endoprostheses). Sixty percent (12/20) underwent endovascular management (4 coil embolization and 8 stent-grafts). Technical success was 83 % (10/12) with a mean arterial patency of 70 % (follow-up mean, 4.9; range, 0-18 months). The 1-, 3-, and 6-month graft survival was 70, 40, and 35 %, respectively. Due to minimally invasive procedures, posttransplant extrahepatic pseudoaneurysms are no longer an exclusive complication of the transplant surgery itself. Endovascular management is effective to stabilize patients but has not improved historic postsurgical graft survival.

  3. Traumatic partial avulsion of a single right subclavian artery from the aortic arch and definitive repair.

    Science.gov (United States)

    Kapetanakis, Emmanouil I; Sears-Rogan, Pamela; Young, Richard S; Kanda, Louis T; Ellis, Jennifer L

    2006-01-01

    Blunt injury to the right subclavian artery is a rare complication of severe deceleration trauma often associated with significant morbidity and mortality. We describe an atypical presentation in a patient who sustained a traumatic avulsion of his right subclavian artery arising off the aortic arch. An interposition graft was used to restore the continuity of the artery to the ascending thoracic aorta.

  4. Covered Stent and Coils Embolization of a Pulmonary Artery Pseudoaneurysm After Gunshot Wound

    International Nuclear Information System (INIS)

    Huet, Nicolas; Rodiere, Mathieu; Badet, Michel; Michoud, Marie; Brichon, Pierre-Yves; Ferretti, Gilbert; Thony, Frédéric

    2016-01-01

    We report the first case of endovascular covered stent implantation for the treatment of a large pulmonary artery pseudoaneurysm (PAPA) following a right thoracic gunshot wound. After resuscitation and hemodynamic stabilization, a CT angiography was performed to analyze the neck size of the PAPA and its position relative to the branches of the parent artery. Covered stent implantation with additional coil embolization was successfully performed. At the 4-year follow-up, the stents remained patent and there was neither pseudoaneurysm recurrence nor treatment-related complication.

  5. Covered Stent and Coils Embolization of a Pulmonary Artery Pseudoaneurysm After Gunshot Wound

    Energy Technology Data Exchange (ETDEWEB)

    Huet, Nicolas, E-mail: nhuet@chu-grenoble.fr; Rodiere, Mathieu, E-mail: mrodiere@chu-grenoble.fr [Hôpital Universitaire de Grenoble and Université Grenoble Alpes, Department of Radiology and Medical Imaging (France); Badet, Michel, E-mail: michel.badet@ch-chambery.fr [Centre Hospitalier Métropôle Savoie, site de Chambéry, Intensive Care Unit (France); Michoud, Marie, E-mail: marie.michoud@ch-chambery.fr [Centre Hospitalier Métropôle Savoie, Site de Chambéry, Department of Radiology (France); Brichon, Pierre-Yves, E-mail: pybrichon@chu-grenoble.fr [Hôpital Universitaire de Grenoble and Université Grenoble Alpes, Department of Thoracic and Vascular Surgery (France); Ferretti, Gilbert, E-mail: gferretti@chu-grenoble.fr; Thony, Frédéric, E-mail: fthony@chu-grenoble.fr [Hôpital Universitaire de Grenoble and Université Grenoble Alpes, Department of Radiology and Medical Imaging (France)

    2016-05-15

    We report the first case of endovascular covered stent implantation for the treatment of a large pulmonary artery pseudoaneurysm (PAPA) following a right thoracic gunshot wound. After resuscitation and hemodynamic stabilization, a CT angiography was performed to analyze the neck size of the PAPA and its position relative to the branches of the parent artery. Covered stent implantation with additional coil embolization was successfully performed. At the 4-year follow-up, the stents remained patent and there was neither pseudoaneurysm recurrence nor treatment-related complication.

  6. Tetralogy of Fallot and aortic root dilation: a long-term outlook.

    Science.gov (United States)

    Nagy, Christian D; Alejo, Diane E; Corretti, Mary C; Ravekes, William J; Crosson, Jane E; Spevak, Philip J; Ringel, Richard; Carson, Kathryn A; Khalil, Sara; Dietz, Harry C; Cameron, Duke E; Vricella, Luca A; Traill, Thomas A; Holmes, Kathryn W

    2013-04-01

    Dilation of the sinus of Valsalva (SoV) has been increasingly observed after repaired tetralogy of Fallot (TOF). We estimate the prevalence of SoV dilation in adults with repaired TOF and analyze possible factors related to aortic disease. Adults with TOF [n = 109, median age 33.2 years (range 18.1 to 69.5)] evaluated at Johns Hopkins Hospital from 2001 to 2009 were reviewed in an observational retrospective cohort study. Median follow-up was 27.3 (range 0.1-48.8) years. SoV dilation was defined as >95 % confidence interval adjusted for age and body surface area (z-score > 2). The prevalence of SoV dilation was 51 % compared with that of a normal population with a mean z-score of 2.03. Maximal aortic diameters were ≥ 4 cm in 39 % (42 of 109), ≥ 4.5 cm in 21 % (23 of 109), ≥ 5 cm in 8 % (9 of 109), and ≥ 5.5 cm in 2 % (2 of 109). There was no aortic dissection or death due contributable to aortic disease. Aortic valve replacement was performed in 1.8 % and aortic root or ascending aorta (AA) replacement surgery in 2.8 % of patients. By multivariate logistic regression analysis, aortic regurgitation (AR) [odds ratio (OR) = 3.09, p = 0.005], residual ventricular septal defect (VSD) (OR = 4.14, p < 0.02), and TOF with pulmonary atresia (TOF/PA) (OR = 6.75, p = 0.03) were associated with increased odds of dilated aortic root. SoV dilation after TOF repair is common and persists with aging. AR, residual VSD, and TOF/PA are associated with increased odds of dilation. AA evaluation beyond the SoV is important. Indexed values are imperative to avoid bias on the basis of age and body surface area.

  7. Proximal thoracic aorta dimensions after continuous-flow left ventricular assist device implantation: Longitudinal changes and relation to aortic valve insufficiency.

    Science.gov (United States)

    Fine, Nowell M; Park, Soon J; Stulak, John M; Topilsky, Yan; Daly, Richard C; Joyce, Lyle D; Pereira, Naveen L; Schirger, John A; Edwards, Brooks S; Lin, Grace; Kushwaha, Sudhir S

    2016-04-01

    In this study we examined the impact of continuous-flow left ventricular assist device (CF-LVAD) support on proximal thoracic aorta dimensions. Aortic root and ascending aorta diameter were measured from serial echocardiograms before and after CF-LVAD implantation in patients with ≥6 months of support, and correlated with the development of >mild aortic valve insufficiency (AI). Of 162 patients included, mean age was 58 ± 11 years and 128 (79%) were male. Seventy-nine (63%) were destination therapy patients. Mean aortic root and ascending aorta diameters at baseline, 1 month, 6 months, 12 months and long-term follow-up (mean 2.0 ± 1.4 years) were 3.5 ± 0.4, 3.5 ± 0.3, 3.9 ± 0.3, 3.9 ± 0.2 and 4.0 ± 0.3, and 3.3 ± 0.2, 3.3 ± 0.3, 3.6 ± 0.2, 3.6 ± 0.3 and 3.6 ± 0.3 cm, respectively. Only change in aortic root diameter from 1-month to 6-month follow-up reached statistical significance (p = 0.03). Nine (6%) patients had accelerated proximal thoracic aorta expansion (>0.5 cm/year), occurring predominantly in the first 6 months after implantation. These patients were older and more likely to have hypertension and baseline proximal thoracic aorta dilation. Forty-five (28%) patients developed >mild AI at long-term follow-up, including 7 of 9 (78%) of those with accelerated proximal thoracic aorta expansion. All 7 had aortic valves that remained closed throughout the cardiac cycle, and this, along with duration of CF-LVAD support and increase in aortic root diameter, were significantly associated with developing >mild AI. CF-LVAD patients have small increases in proximal thoracic aorta dimensions that predominantly occur within the first 6 months after implantation and then stabilize. Increasing aortic root diameter was associated with AI development. Copyright © 2016 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  8. Left ventricular outflow tract to left atrial communication secondary to rupture of mitral-aortic intervalvular fibrosa in infective endocarditis: diagnosis by transesophageal echocardiography and color flow imaging.

    Science.gov (United States)

    Bansal, R C; Graham, B M; Jutzy, K R; Shakudo, M; Shah, P M

    1990-02-01

    Infection of the mitral-aortic intervalvular fibrosa occurs most commonly in association with infective endocarditis of the aortic valve. Infection of the aortic valve results in a regurgitant jet that presumably strikes this subaortic interannular zone of fibrous tissue and produces a secondary site of infection. Infection of this interannular zone then leads to the formation of subaortic abscess or pseudoaneurysm of the left ventricular outflow tract. This infected zone of mitral-aortic intervalvular fibrosa or subaortic aneurysm can subsequently rupture into the left atrium with systolic ejection of blood from the left ventricular outflow tract to the left atrium. This report describes the echocardiographic findings in three patients with pathologically proved left ventricular outflow tract to left atrial communication. Precise preoperative diagnosis is important, and this lesion should be differentiated from ruptured aneurysm of the sinus of Valsalva and perforation of the anterior mitral leaflet. Transthoracic echocardiography using color flow imaging and conventional Doppler techniques may show an eccentric mitral regurgitation type of signal in the left atrium originating from the region of the left ventricular outflow tract. However, transesophageal echocardiography provides an accurate preoperative diagnosis and should be used intraoperatively during repair of such lesions.

  9. Massive epistaxis due to pseudoaneurysm of the sphenopalatine artery: a rare post-operative complication of orthognathic surgery.

    Science.gov (United States)

    Kim, Y-W; Baek, M-J; Kim, H-D; Cho, K-S

    2013-06-01

    To introduce pseudoaneurysm of the sphenopalatine artery as the possible aetiology of acute massive epistaxis in patients with a history of orthognathic surgery accompanied by Le Fort I osteotomy. Case report and literature review. This paper reports a case of acute life-threatening epistaxis following Le Fort I osteotomy. Computed tomography and angiography showed a pseudoaneurysm of the sphenopalatine artery, which was successfully treated by endovascular embolisation. Although a pseudoaneurysm of the sphenopalatine artery following Le Fort I osteotomy is extremely rare, it should be considered as the possible aetiology of acute massive epistaxis in patients with a history of orthognathic surgery accompanied by Le Fort I osteotomy.

  10. Cardiovascular Disease in Ageing: An Overview on Thoracic Aortic Aneurysm as an Emerging Inflammatory Disease

    Directory of Open Access Journals (Sweden)

    Calogera Pisano

    2017-01-01

    Full Text Available Medial degeneration associated with thoracic aortic aneurysm and acute aortic dissection was originally described by Erdheim as a noninflammatory lesion related to the loss of smooth muscle cells and elastic fibre fragmentation in the media. Recent evidences propose the strong role of a chronic immune/inflammatory process in aneurysm evocation and progression. The coexistence of inflammatory cells with markers of apoptotic vascular cell death in the media of ascending aorta with aneurysms and type A dissections raises the possibility that activated T cells and macrophages may contribute to the elimination of smooth muscle cells and degradation of the matrix. On the other hand, several inflammatory pathways (including TGF-β, TLR-4 interferon-γ, chemokines, and interferon-γ seem to be involved in the medial degeneration related to aged and dilated aorta. This is an overview on thoracic aortic aneurysm as an emerging inflammatory disease.

  11. Spontaneous occlusion of post-traumatic splenic pseudoaneurysm: report of two cases in children

    Energy Technology Data Exchange (ETDEWEB)

    Raghavan, Ashok; Wong, Christopher Kah Fook; Lam, Albert; Stockton, Vivienne [Department of Medical Imaging, The Children' s Hospital at Westmead, Sydney (Australia)

    2004-04-01

    Conservative therapy for splenic injuries is widely advocated. The advantages of conservative therapy for splenic injuries include the preservation of splenic immune function, prevention of overwhelming post-splenectomy sepsis, and avoidance of laparotomy and its associated early and late complications. Pseudoaneurysms of the splenic artery branch are encountered because of the prevalence of conservative management and widespread use of imaging techniques in the follow-up of these cases. We report two cases of post-traumatic splenic pseudoaneurysm in children which thrombosed spontaneously, one during the diagnostic angiogram examination and another on follow-up studies. (orig.)

  12. Diagnosis and Management of Transplanted Kidney Extrarenal Pseudoaneurysms: A Series of Four Cases and a Review of the Literature

    Energy Technology Data Exchange (ETDEWEB)

    Fananapazir, Ghaneh, E-mail: fananapazir@ucdavis.edu [University of California Davis Medical Center, Department of Radiology (United States); Hannsun, Gemmy [University of California Sacramento Medical Center, School of Medicine (United States); Wright, Luke A.; Corwin, Michael T. [University of California Davis Medical Center, Department of Radiology (United States); Troppmann, Christoph [University of California Davis Medical Center, Department of Surgery (United States)

    2016-11-15

    Extrarenal pseudoaneurysms of transplanted kidneys are very rare but can have devastating consequences. In the past, these extrarenal pseudoaneurysms have often led to graft loss as well as significant morbidity and mortality. The role of advanced diagnostic imaging studies and of modern radiologic interventional management has not been studied. In this case series, we present four cases of extrarenal pseudoaneurysms of transplanted kidneys, describe the clinical scenarios and imaging that led to the angiographic diagnosis, and discuss the various endovascular and surgical approaches to management.

  13. Massive Upper Gastrointestinal Bleeding from a Splenic Artery Pseudoaneurysm Caused by a Penetrating Gastric Ulcer: Case Report and Review of Literature

    International Nuclear Information System (INIS)

    Sawicki, Marcin; Marlicz, Wojciech; Czapla, Norbert; Łokaj, Marek; Skoczylas, Michał M.; Donotek, Maciej; Kołaczyk, Katarzyna

    2015-01-01

    Splenic artery aneurysm and pseudoaneurysm are rare pathologies. True aneurysms are usually asymptomatic. Aneurysm rupture occurring in 2–3% of cases results in bleeding into the lesser sack, peritoneal space or adjacent organs typically presenting as abdominal pain and hemodynamic instability. In contrast, pseudoaneurysms are nearly always symptomatic carrying a high risk of rupture of 37–47% and mortality rate of 90% if untreated. Therefore, prompt diagnosis and treatment are essential in the management of patients with splenic artery pseudoaneurysm. Typical causes include pancreatitis and trauma. Rarely, the rupture of a pseudoaneurysm presents as upper gastrointestinal (UGI) bleeding. Among causes, peptic ulcer is the casuistic one. This report describes a very rare case of recurrent UGI bleeding from a splenic artery pseudoaneurysm caused by a penetrating gastric ulcer. After negative results of endoscopy and ultrasound, the diagnosis was established in CT angiography. The successful treatment consisted of surgical ligation of the bleeding vessel and suture of the ulcer with preservation of the spleen and pancreas, which is rarely tried in such situations. The most important factor in identifying a ruptured splenic artery pseudoaneurysm as a source of GI bleeding is considering the diagnosis. UGI hemorrhage from splenic artery pseudoaneurysm can have a relapsing course providing false negative results of endoscopy and ultrasound if performed between episodes of active bleeding. In such cases, immediate CT angiography is useful in establishing diagnosis and in application of proper therapy before possible recurrence

  14. CT and MR imaging of post-aortic left brachiocephalic vein

    Energy Technology Data Exchange (ETDEWEB)

    Amano, Yasuo; Takagi, Ryo; Hayashi, Hiromitsu; Kumazaki, Tatsuo (Nippon Medical School, Tokyo (Japan))

    1993-10-01

    The usefulness of CT and MR imaging (MRI) for the diagnosis of post-aortic left brachiocephalic vein (PALBV) is discussed. The subjects of the present study consisted of five patients with PALBV, two males and three females, aged for months to sixty years. Chest CT and MRI were performed as a follow-up study of other intrathoracic lesions in two cases, and for further examination of congenital heart diseases in two infant cases. The other patient underwent both CT and MRI to evaluate sporadic chest pain. Therefore, all PALBV were found incidentally. PALBV passes below the aortic arch in front of the trachea, draining the superior vena cava behind the ascending aorta. The finding was particularly well documented on consecutive coronal sections on MRI. In patients with intrathoracic malignant or specific inflammatory lesion, differentiation between PALBV and lymphadenopathy is necessary for treatment. From our experience, marked enhancement on CT and no signal intensity on MRI in PALBV could differentiate this anomaly from mediastinal lymphadenopathy. In two infantile cases with congenital cardiovascular anomalies such as tetralogy of Fallot, right aortic arch and pulmonary arterial stenosis, MRI was found to be superior to CT in demonstrating these anomalies. (author).

  15. CT and MR imaging of post-aortic left brachiocephalic vein

    International Nuclear Information System (INIS)

    Amano, Yasuo; Takagi, Ryo; Hayashi, Hiromitsu; Kumazaki, Tatsuo

    1993-01-01

    The usefulness of CT and MR imaging (MRI) for the diagnosis of post-aortic left brachiocephalic vein (PALBV) is discussed. The subjects of the present study consisted of five patients with PALBV, two males and three females, aged for months to sixty years. Chest CT and MRI were performed as a follow-up study of other intrathoracic lesions in two cases, and for further examination of congenital heart diseases in two infant cases. The other patient underwent both CT and MRI to evaluate sporadic chest pain. Therefore, all PALBV were found incidentally. PALBV passes below the aortic arch in front of the trachea, draining the superior vena cava behind the ascending aorta. The finding was particularly well documented on consecutive coronal sections on MRI. In patients with intrathoracic malignant or specific inflammatory lesion, differentiation between PALBV and lymphadenopathy is necessary for treatment. From our experience, marked enhancement on CT and no signal intensity on MRI in PALBV could differentiate this anomaly from mediastinal lymphadenopathy. In two infantile cases with congenital cardiovascular anomalies such as tetralogy of Fallot, right aortic arch and pulmonary arterial stenosis, MRI was found to be superior to CT in demonstrating these anomalies. (author)

  16. [Images in cardiology after clinical observation - aortic dissection in Marfan syndrome].

    Science.gov (United States)

    Cabanelas, Nuno; Nobre, Angelo; Guerra, Nuno; Gallego, Javier; Ferreira, Ricardo; Carvalheiro, Catarina; Roque, João; Peres, Marisa; Siopa, Luís; Martins, Vítor Paulo; Silva, Graça; Cravino, João

    2011-09-01

    Stanford type A aortic dissection is a rare phenomenon with high short-term mortality and clinical manifestations that can make differential diagnosis a lengthy process requiring several diagnostic examinations. Based on a case report, the aim is to highlight the importance of physical examination in the initial management of these patients and of rapid access to a surgical center. A brief review follows on the diagnosis and treatment of ascending aortic dissection, and its specific nature in Marfan syndrome. A 33-year-old man was admitted to the emergency department of a district hospital with chest and back pain associated with vomiting, 20 hours after symptom onset. Initial physical examination revealed an aortic systolic murmur and musculoskeletal morphological abnormalities compatible with Marfan syndrome. Given suspected aortic dissection, a transthoracic echocardiogram was immediately performed, which showed an extensive intimal flap originating at the sinotubular junction. He was transferred to the cardiothoracic surgery department of a referral hospital where he was treated by a Bentall procedure. In this case, careful physical examination during initial assessment raised the suspicion that this patient was in a high-risk group for aortic dissection, thus avoiding unnecessary and lengthy exams. This diagnosis requires emergent surgical treatment, and so direct contact in real time between those making in the diagnosis and the surgeon is essential, as well as protocols governing immediate access to a surgical center. Copyright © 2011 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  17. 5B.05: MARFAN SYNDROME: ASSESSMENT OF AORTIC DISSECTION RISK BY ANALYSIS OF AORTIC VISCOELASTIC PROPERTIES.

    Science.gov (United States)

    Grillo, A; Pini, A; Marelli, S; Gan, L; Giuliano, A; Trifirò, G; Santini, F; Salvi, L; Salvi, P; Viecca, F; Carretta, R; Parati, G

    2015-06-01

    Marfan syndrome is an autosomal dominant genetic disorder characterized by an abnormal fibrillin-1 synthesis. Aortic root dilation and dissection are the main problems affecting patients prognosis in these patients. Their pharmacological prophylaxis with losartan or with a beta-blocker counteracts the aortic root dilation, but a close follow-up is required to assess therapeutic response rate and to identify non-responders. Unfortunately genotype-phenotype studies do not allow to determine the exact risk profile in these patients and there is no reliable method to accurately predict their risk of aortic dissection. Aim of this study was to evaluate non-invasive markers for identification of Marfan patients at higher risk of aortic complications. We studied 187 Marfan patients (identified according to 2010 Revised Ghent Criteria and positive genetic analysis), age 32.3 ± 16.5 yrs (mean ± SD). 52 patients (27.8%) had undergone surgical ascending aorta replacement (David or Bentall procedure). Central pressure curves were recorded by PulsePen tonometer, and the aortic viscoelastic aortic properties were studied by determination of carotid-femoral pulse wave velocity (PWV). With reference to the age related distribution of PWV values in a normal population, defined according to Arterial-Stiffness-Collaboration, PWV mean values in Marfan patients corresponded to 60th percentile in non- operated patients and to the 67th percentile in those operated. Adult Marfan patients (n = 146) generally displayed a low blood pressure, because of the pharmacological prophylaxis, and were compared with a population of 189 adult healthy subjects (81 males), matched by age (38 ± 13 vs 38 ± 16 yrs.), heart rate (64 ± 9 bpm vs 64 ± 11 bpm) and blood pressure (mean BP = 78 ± 9 mmHg vs 79 ± 4 mmHg) values. Average PWV value was higher than in healthy controls (PWV = 7.0 ± 1.7) both in not operated (PWV = 7.6 ± 1.6; p = 0

  18. A case of pseudoaneurysm due to fungus ball within the progressive massive fibrosis in a patient with pneumoconiosis: Computed tomography-pathologic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Geun; Ryu, Dae Shick; Park, Man Soo; Choi, Soo Jung; Kang, Chae Hoon; Shin, Dong Rock; Ahn, Jae Hong [Dept. of Radiology, Gangneung Asan Hospital, College of Medicine, University of Ulsan, Gangneung (Korea, Republic of)

    2016-09-15

    We reported a case of pseudoaneurysm in the upper lobar branch of the right pulmonary artery, which was caused by a fungus ball within the progressive massive fibrosis (PMF) in a patient with pneumoconiosis. Coil embolization of the pseudoaneurysm initially stopped the bleeding. After right upper lobe lobectomy to prevent the recurrent hemoptysis, pathology confirmed pseudoaneurysm within the PMF due to aspergilloma.

  19. Bentall and De Bono surgery for correction of valve and ascending aortic disease: long-term results.

    Science.gov (United States)

    Silva, Virgílio Figueiredo; Real, Daniel Sundfeld Spiga; Branco, João Nelson Rodrigues; Catani, Roberto; Kim, Hyong Chun; Buffolo, Enio; Fonseca, José Honório de Almeida Palma da

    2008-01-01

    A retrospective study was performed in a series of consecutive patients who underwent a Bentall and De Bono procedure. Data were removed of medical records and follow-up data were obtained from clinical records and direct contact with patients. A total of 39 patients were studied between January 1996 and December 2005. The median age was 47 years (range 14-70). There were 33 males and six females. Eleven (25.5%) patients presented Marfan syndrome and one (2.5%) Turner syndrome. Nineteen (48.5%) patients had hypertension, eight (20.5%) had history of smoking, six (15.5%) had history of alcoholism, eight (20.5%) had dyslipidemia, two (5.0%) had diabetes and one (2.56%) had myocardial infarct previously. Twenty-eight (72%) patients were in II-III NYHA class in the moment of the surgery. Annulo-aortic ecstasy was present in 14 (35.9%) patients and aortic aneurysms in 16 (41%). The median time in intensive care unit was 8.79 days with range 2-23 days. Four (10.0%) patients underwent an emergency operation and 35 (90%) elective. The overall hospital mortality was 5% (2/39). The event-free survival is 94.87% at 1 year and 84.61% at in 5 and 10. The median time of follow-up was 46.5 months (range 14-120 months). The Bentall and De Bono technique obtained excellent results in the short-term and long-term, which support the continued use of the compositive graft technique as the preferred method of treatment for patients with aortic root disease. Our findings confirm the current literature data.

  20. Intracranial hemorrhage due to intracranial hypertension caused by the superior vena cava syndrome

    DEFF Research Database (Denmark)

    Bartek, Jiri; Abedi-Valugerdi, Golbarg; Liska, Jan

    2013-01-01

    We report a patient with intracranial hemorrhage secondary to venous hypertension as a result of a giant aortic pseudoaneurysm that compressed the superior vena cava and caused obstruction of the venous return from the brain. To our knowledge, this is the first patient reported to have...... an intracranial hemorrhage secondary to a superior vena cava syndrome. The condition appears to be caused by a reversible transient rise in intracranial pressure, as a result of compression of the venous return from the brain. Treatment consisted of surgery for the aortic pseudoaneurysm, which led...

  1. Exact monitoring of aortic diameters in Marfan patients without gadolinium contrast: intraindividual comparison of 2D SSFP imaging with 3D CE-MRA and echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Veldhoen, Simon [University Medical Center Wuerzburg, Department of Diagnostic and Interventional Radiology, Bavaria (Germany); University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Behzadi, Cyrus; Derlin, Thorsten; Henes, Frank Oliver; Adam, Gerhard; Bannas, Peter [University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Rybczinsky, Meike; Kodolitsch, Yskert von; Sheikhzadeh, Sara [University Medical Center Hamburg-Eppendorf, Department of General and Interventional Cardiology, Hamburg (Germany); Bley, Thorsten Alexander [University Medical Center Wuerzburg, Department of Diagnostic and Interventional Radiology, Bavaria (Germany)

    2014-10-15

    To assess whether ECG-gated non-contrast 2D steady-state free precession (SSFP) imaging allows for exact monitoring of aortic diameters in Marfan syndrome (MFS) patients using non-ECG-gated contrast-enhanced 3D magnetic resonance angiography (CE-MRA) and echocardiography for intraindividual comparison. Non-ECG-gated CE-MRA and ECG-gated non-contrast SSFP at 1.5 T were prospectively performed in 50 patients. Two readers measured aortic diameters on para-sagittal images identically aligned with the aortic arch at the sinuses of Valsalva, sinotubular junction, ascending/descending aorta and aortic arch. Image quality was assessed on a three-point scale. Aortic root diameters acquired by echocardiography were used as reference. Intra- and interobserver variances were smaller for SSFP at the sinuses of Valsalva (p = 0.002; p = 0.002) and sinotubular junction (p = 0.014; p = 0.043). Image quality was better in SSFP than in CE-MRA at the sinuses of Valsalva (p < 0.0001), sinotubular junction (p < 0.0001) and ascending aorta (p = 0.02). CE-MRA yielded higher diameters than SSFP at the sinuses of Valsalva (mean bias, 2.5 mm; p < 0.0001), and comparison with echocardiography confirmed a higher bias for CE-MRA (7.2 ± 3.4 mm vs. SSFP, 4.7 ± 2.6 mm). ECG-gated non-contrast 2D SSFP imaging provides superior image quality with higher validity compared to non-ECG-gated contrast-enhanced 3D imaging. Since CE-MRA requires contrast agents with potential adverse effects, non-contrast SSFP imaging is an appropriate alternative for exact and riskless aortic monitoring of MFS patients. (orig.)

  2. Exact monitoring of aortic diameters in Marfan patients without gadolinium contrast: intraindividual comparison of 2D SSFP imaging with 3D CE-MRA and echocardiography

    International Nuclear Information System (INIS)

    Veldhoen, Simon; Behzadi, Cyrus; Derlin, Thorsten; Henes, Frank Oliver; Adam, Gerhard; Bannas, Peter; Rybczinsky, Meike; Kodolitsch, Yskert von; Sheikhzadeh, Sara; Bley, Thorsten Alexander

    2015-01-01

    To assess whether ECG-gated non-contrast 2D steady-state free precession (SSFP) imaging allows for exact monitoring of aortic diameters in Marfan syndrome (MFS) patients using non-ECG-gated contrast-enhanced 3D magnetic resonance angiography (CE-MRA) and echocardiography for intraindividual comparison. Non-ECG-gated CE-MRA and ECG-gated non-contrast SSFP at 1.5 T were prospectively performed in 50 patients. Two readers measured aortic diameters on para-sagittal images identically aligned with the aortic arch at the sinuses of Valsalva, sinotubular junction, ascending/descending aorta and aortic arch. Image quality was assessed on a three-point scale. Aortic root diameters acquired by echocardiography were used as reference. Intra- and interobserver variances were smaller for SSFP at the sinuses of Valsalva (p = 0.002; p = 0.002) and sinotubular junction (p = 0.014; p = 0.043). Image quality was better in SSFP than in CE-MRA at the sinuses of Valsalva (p < 0.0001), sinotubular junction (p < 0.0001) and ascending aorta (p = 0.02). CE-MRA yielded higher diameters than SSFP at the sinuses of Valsalva (mean bias, 2.5 mm; p < 0.0001), and comparison with echocardiography confirmed a higher bias for CE-MRA (7.2 ± 3.4 mm vs. SSFP, 4.7 ± 2.6 mm). ECG-gated non-contrast 2D SSFP imaging provides superior image quality with higher validity compared to non-ECG-gated contrast-enhanced 3D imaging. Since CE-MRA requires contrast agents with potential adverse effects, non-contrast SSFP imaging is an appropriate alternative for exact and riskless aortic monitoring of MFS patients. (orig.)

  3. Severe hydronephrosis secondary to uterine artery pseudoaneurysm in the early second trimester of pregnancy: A case report.

    Science.gov (United States)

    Amano, Tsukuru; Tokoro, Shinsuke; Tsuji, Shunichiro; Inoue, Takashi; Kimura, Fuminori; Murakami, Takashi

    2017-09-25

    Uterine artery pseudoaneurysm (UAP) normally presents genital bleeding in the puerperal period, and severe hydronephrosis rarely presents during pregnancy. We report a rare case of severe ureteral obstruction accompanied by uterine artery pseudoaneurysm in the early second trimester of pregnancy, which was successfully treated by surgical intervention. A 42-year-old nulligravid woman who had undergone myomectomy 3 years earlier was referred to our hospital for acute left abdominal pain at the 17th week of gestation. Ultrasonography showed severe left hydronephrosis and a 6-cm mass in the parauterine space. Color Doppler ultrasonography revealed a spinning turbulent flow pattern inside the mass lesion. Contrast-enhanced computed tomography revealed the left uterine artery feeding blood flow to the mass and left ureteral obstruction by the mass. These results indicated left hydronephrosis secondary to left uterine artery pseudoaneurysm. To resolve the problem, laparotomy was performed. As uterine artery isolation was impossible, ligation of the left internal iliac artery and releasing of the ureteral obstruction were carried out. The hydronephrosis and abdominal pain promptly resolved after the surgery. Thereafter, fetal development proceeded normally in the remaining months of the pregnancy. A healthy baby was delivered through cesarean section at 36 weeks gestational age. At the cesarean section, the left lower uterine segment where the UAP had been present was not visible because of the firm adhesion in around it. Uterine artery pseudoaneurysm can cause hydronephrosis in the early second trimester of pregnancy. Ligation of the unilateral internal iliac artery is a safe and effective intervention to block the blood flow to the uterine artery pseudoaneurysm during pregnancy, when uterine artery ligation seems not possible. In the pregnancy after previous surgical procedures to the uterus, uterine artery pseudoaneurysm should be considered in the differential

  4. Hemobilia into a metallic biliary stent due to pseudoaneurysm. A case report

    International Nuclear Information System (INIS)

    Morishita, Naoki; Nishida, Tsutomu; Hayashi, Yoshito

    2013-01-01

    A 48-year-old man with locally advanced pancreatic cancer underwent combined treatment with gemcitabine and proton radiation therapy. Because of subsequent obstruction of the common bile duct, a metallic biliary stent was placed and he received further gemcitabine chemotherapy. During chemotherapy, he developed an acute abdomen with a sudden-onset of tarry stool and jaundice. Gastroduodenoscopy revealed hemobilia from the biliary metallic stent. Contrast-enhanced abdominal computed tomography revealed the presence of a pseudoaneurysm arising from the right hepatic artery adjacent to the top of the stent. Hemostasis of the right hepatic artery pseudoaneurysm was achieved via transcatheter arterial embolization using cyanoacrylate. (author)

  5. Deficient Circumferential Growth Is the Primary Determinant of Aortic Obstruction Attributable to Partial Elastin Deficiency.

    Science.gov (United States)

    Jiao, Yang; Li, Guangxin; Korneva, Arina; Caulk, Alexander W; Qin, Lingfeng; Bersi, Matthew R; Li, Qingle; Li, Wei; Mecham, Robert P; Humphrey, Jay D; Tellides, George

    2017-05-01

    Williams syndrome is characterized by obstructive aortopathy attributable to heterozygous loss of ELN , the gene encoding elastin. Lesions are thought to result primarily from excessive smooth muscle cell (SMC) proliferation and consequent medial expansion, although an initially smaller caliber and increased stiffness of the aorta may contribute to luminal narrowing. The relative contributions of such abnormalities to the obstructive phenotype had not been defined. We quantified determinants of luminal stenosis in thoracic aortas of Eln -/- mice incompletely rescued by human ELN . Moderate obstruction was largely because of deficient circumferential growth, most prominently of ascending segments, despite increased axial growth. Medial thickening was evident in these smaller diameter elastin-deficient aortas, with medial area similar to that of larger diameter control aortas. There was no difference in cross-sectional SMC number between mutant and wild-type genotypes at multiple stages of postnatal development. Decreased elastin content was associated with medial fibrosis and reduced aortic distensibility because of increased structural stiffness but preserved material stiffness. Elastin-deficient SMCs exhibited greater contractile-to-proliferative phenotypic modulation in vitro than in vivo. We confirmed increased medial collagen without evidence of increased medial area or SMC number in a small ascending aorta with thickened media of a Williams syndrome subject. Deficient circumferential growth is the predominant mechanism for moderate obstructive aortic disease resulting from partial elastin deficiency. Our findings suggest that diverse aortic manifestations in Williams syndrome result from graded elastin content, and SMC hyperplasia causing medial expansion requires additional elastin loss superimposed on ELN haploinsufficiency. © 2017 American Heart Association, Inc.

  6. MCP-1, ICAM-1 and VCAM-1 are present in early aneurysmal dilatation in experimental rats

    International Nuclear Information System (INIS)

    Jun Fan; Hao-Tong; Jing Di; Fang Liu; Hai-Hua Zhao; Shu-Ling Bai; Xiang Li; Linlin Zhong

    2010-01-01

    Recent studies have suggested that inflammation actively participates in ascending aortic aneurysm formation. The aim of the present study was to evaluate the expression changes of adhesion molecules and MMPs in an experimental model of ascending aortic aneurysm induced by ascending aorta banding in Wistar rats. Twelve rats developed aortic dilation after ascending aorta banding treatment, while nine normal animals underwent surgery without banding were used as controls. Light microscope and scanning electron microscope showed that the wall of the ascending aorta became disorganized as well as infiltration by inflammatory cells in aneurysmal rats. By using immunohistochemical techniques, a significant increase in the immunostaining of MCP-1 was observed in the aneurysmal wall as compared to the normal aortic wall. Under similar experimental conditions, we also found that the immunostaining of ICAM-1 and VCAM-1 was markedly increased in the aneurysmal wall. In addition, gelatin zymo graphic analysis showed that the expression and activities of MMP-2 and MMP-9 were remarkably enhanced in the ascending aorta of ascending aortic aneurysmal rats as compared to normal rats. These results demonstrate that MCP-1, ICAM-1 and VCAM-1 are involved in the pathogenesis of ascending aortic aneurysm and an increase in the immunostaining and activity of MMP-2 and MMP-9 may promote the progression of ascending aortic aneurysm. (authors)

  7. Mid-term follow-up of aortic root remodelling compared to Bentall operation.

    Science.gov (United States)

    Bassano, C; De Matteis, G M; Nardi, P; Buratta, M M; Zeitani, J; De Paulis, R; Chiariello, L

    2001-05-01

    Aortic valve sparing with root remodelling has proven useful in cases of aortic regurgitation secondary to ascending aorta disease. An excessive rate of re-operation for recurrent aortic regurgitation after this conservative approach might compensate the prosthesis-related risk of the Bentall operation. From January 1995 to September 2000, 69 consecutive patients with aortic expansive aneurysm and concomitant aortic valve disease, were submitted to the Bentall operation (group A, n=37) in the presence of an abnormal valve, or to root remodelling (group B, n=32) in cases of secondary aortic incompetence. One patient in group A and four in group B had Marfan syndrome. The follow-up was 1021 patient-months (range, 1-68 months) in group A and 926 in group B (1-64 months). The event-free survival was calculated using the Kaplan-Meier method, and the difference between curves was evaluated using the Mantel-Cox log-rank test. The operative mortality was 5% in group A and 0% in group B. One patient died at follow-up in group A and none in group B. Four patients (three Marfan) in group B were re-operated on because of recurrent aortic regurgitation. The 5-year event-free survival was 88+/-7% in group A and 82+/-8% in group B (P=0.58). Early residual aortic regurgitation remained stable over time only in patients with good early results. Mid-term follow-up failed to reveal statistically significant differences in the clinical outcome between remodelling and the Bentall operation. Our results support the widespread use of root remodelling, provided that an indication to this conservative approach is achieved after careful, case-by-case evaluation. A good early operative result is likely to remain stable over time.

  8. Interrupted Aortic Arch Associated with Absence of Left Common Carotid Artery: Imaging with MDCT

    International Nuclear Information System (INIS)

    Onbas, Omer; Olgun, Hasim; Ceviz, Naci; Ors, Rahmi; Okur, Adnan

    2006-01-01

    Interrupted aortic arch (IAA) is a rare severe congenital heart defect defined as complete luminal and anatomic discontinuity between ascending and descending aorta. Although its association with various congenital heart defects has been reported, absence of left common carotid artery (CCA) in patients with IAA has not been reported previously. We report a case of IAA associated with the absence of left CCA which was clearly shown on multidetector-row spiral CT

  9. Stent-Graft Placement with Early Debridement and Antibiotic Treatment for Femoral Pseudoaneurysms in Intravenous Drug Addicts

    International Nuclear Information System (INIS)

    Fu, Qining; Meng, Xiyun; Li, Fenghe; Wang, Xuehu; Cheng, Jun; Huang, Wen; Ren, Wei; Zhao, Yu

    2015-01-01

    PurposeExplore the application of endovascular covered stent-graft (SG) placement in femoral pseudoaneurysms in intravenous drug addicts.Materials and MethodsWe evaluated a consecutive series of pseudoaneurysm in intravenous drug addicts treated with SGs from August 2010 to December 2013.Results15 patients with 16 arterial pseudoaneurysms were enrolled in this study. All were males with a mean age of 36.9 years. Hemorrhage was the most common reason (93.8 %) for seeking medical care, and 3 of these patients were in hemorrhagic shock at admission. All patients received broad-spectrum antibiotics, and debridement and drainage were implemented after SG placement. 7 of the 13 cases which had microbiologic results showed mixed infections, while gram-negative bacteria were the major pathogens. Except for 2 patients, who were lost to follow-up, two new pseudoaneurysms formed due to delayed debridement, and one stent thrombosis occurred, none of the remaining cases had SG infection or developed claudication.ConclusionsSG placement controls massive hemorrhage rapidly, gives enough time for subsequent treatment for pseudoaneurysms due to intravenous drug abuse, and reduces the incidence of postoperative claudication. With appropriate broad-spectrum antibiotics and early debridement, the incidence of SG infection is relatively low. It is an effective alternative especially as temporary bridge measure for critical patients. However, the high cost, uncertain long-term prospects, high demand for medical adherence, and the risk of using the conduits for re-puncture call for a cautious selection of patients. More evidence is required for the application of this treatment

  10. Stent-Graft Placement with Early Debridement and Antibiotic Treatment for Femoral Pseudoaneurysms in Intravenous Drug Addicts

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Qining, E-mail: cqmufqn@163.com; Meng, Xiyun, E-mail: 383274177@qq.com; Li, Fenghe, E-mail: lfh-cqmu@gmail.com; Wang, Xuehu, E-mail: 184037696@qq.co; Cheng, Jun, E-mail: cqdcj@163.com; Huang, Wen, E-mail: dhuangwen@hotmail.com; Ren, Wei, E-mail: renwei9771@yahoo.com.cn; Zhao, Yu, E-mail: zhaoyu-cqmu@126.com [The First Affiliated Hospital of Chongqing Medical University, Department of Vascular Surgery (China)

    2015-06-15

    PurposeExplore the application of endovascular covered stent-graft (SG) placement in femoral pseudoaneurysms in intravenous drug addicts.Materials and MethodsWe evaluated a consecutive series of pseudoaneurysm in intravenous drug addicts treated with SGs from August 2010 to December 2013.Results15 patients with 16 arterial pseudoaneurysms were enrolled in this study. All were males with a mean age of 36.9 years. Hemorrhage was the most common reason (93.8 %) for seeking medical care, and 3 of these patients were in hemorrhagic shock at admission. All patients received broad-spectrum antibiotics, and debridement and drainage were implemented after SG placement. 7 of the 13 cases which had microbiologic results showed mixed infections, while gram-negative bacteria were the major pathogens. Except for 2 patients, who were lost to follow-up, two new pseudoaneurysms formed due to delayed debridement, and one stent thrombosis occurred, none of the remaining cases had SG infection or developed claudication.ConclusionsSG placement controls massive hemorrhage rapidly, gives enough time for subsequent treatment for pseudoaneurysms due to intravenous drug abuse, and reduces the incidence of postoperative claudication. With appropriate broad-spectrum antibiotics and early debridement, the incidence of SG infection is relatively low. It is an effective alternative especially as temporary bridge measure for critical patients. However, the high cost, uncertain long-term prospects, high demand for medical adherence, and the risk of using the conduits for re-puncture call for a cautious selection of patients. More evidence is required for the application of this treatment.

  11. Contemporary Management of Type B Aortic Dissection in the Endovascular Era.

    Science.gov (United States)

    Bannazadeh, Mohsen; Tadros, Rami O; McKinsey, James; Chander, Rajiv; Marin, Michael L; Faries, Peter L

    2016-04-01

    Aortic dissection (AD) is one of the most common catastrophic pathologies affecting the aorta. Anatomic classification is based on the origin of entry tear and its extension. Type A dissections originate in the ascending aorta, whereas the entry tear in Type B dissections starts distal to the left subclavian artery. The patients with aortic dissection who manifest complications such as rupture, malperfusion, aneurysmal degeneration, and intractable pain are classified as complicated AD. Risk factors for developing aortic dissection include age, male gender, and aortic wall structural abnormalities. The most common presenting symptom of acute aortic dissection is pain. Malperfusion occurs as a result of end-organ ischemia due to involvement of aortic branches from the dissecting process. This can happen in various locations causing mesenteric ischemia (mesenteric vessels), stroke (aortic arch vessels), renal failure (renal arteries), spinal ischemia, and limb ischemia (iliac or subclavian arteries). Aneurysmal degeneration is the most common complication of patients with chronic Type B dissection who are managed with medical therapy. Management of Type B aortic dissection (TBAD) remains controversial. Many groups recommend conservative therapy for newly diagnosed TBAD and reserve surgical management for patients who develop complications such as rupture, malperfusion, aneurysmal dilatation, and refractory pain. The mainstay of medical therapy includes antihypertensive medication to reduced ΔP/ ΔT by lowering blood pressure and heart rate. With the continued success of thoracic endovascular aortic repair (TEVAR), this procedure has been extended to treat TBAD in selected patients. The outcomes of TEVAR are promising, with early mortality rates from 10% to 20%. With promising results from these series, some groups recommend early TEVAR in uncomplicated TBAD to prevent future adverse events. The goals of endovascular treatment of TBAD are to cover the entry tear

  12. Spontaneous pseudoaneurysm of the uterine artery during pregnancy treated by direct thrombin injection: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Jung Hee; Kim, See Hyung; Kim, Young Hwan [Dept. Radiology, Keimyung University School of Medicine, Dongsan Medical Center, Daegu (Korea, Republic of)

    2016-04-15

    Pseudoaneurysm of uterine artery during pregnancy is a very rare disease. It is mostly associated with uterine artery injury, usually occurring after proceeding conditions such as history of gynecologic operation and infection. However, the best treatment modality has not been established yet. Herein, we reported a case of spontaneous formation of uterine artery pseudoaneurysm during pregnancy treated by direct thrombin injection without any complication or recurrence.

  13. Spontaneous pseudoaneurysm of the uterine artery during pregnancy treated by direct thrombin injection: A case report

    International Nuclear Information System (INIS)

    Hong, Jung Hee; Kim, See Hyung; Kim, Young Hwan

    2016-01-01

    Pseudoaneurysm of uterine artery during pregnancy is a very rare disease. It is mostly associated with uterine artery injury, usually occurring after proceeding conditions such as history of gynecologic operation and infection. However, the best treatment modality has not been established yet. Herein, we reported a case of spontaneous formation of uterine artery pseudoaneurysm during pregnancy treated by direct thrombin injection without any complication or recurrence

  14. Neonatal aortic arch reconstruction avoiding circulatory arrest and direct arch vessel cannulation.

    Science.gov (United States)

    Tchervenkov, C I; Korkola, S J; Shum-Tim, D; Calaritis, C; Laliberté, E; Reyes, T U; Lavoie, J

    2001-11-01

    Aortic arch reconstruction in neonates routinely requires deep hypothermic circulatory arrest. We reviewed our experience with techniques of continuous low-flow cerebral perfusion (LFCP) avoiding direct arch vessel cannulation. Eighteen patients, with a median age of 11 days (range 1 to 85 days) and a mean weight of 3.2 +/- 0.8 kg, underwent aortic arch reconstruction with LFCP. Seven had biventricular repairs with arch reconstruction, 9 underwent the Norwood operation and 2 had isolated arch repairs. In 1 Norwood and 7 biventricular repair patients, LFCP was maintained by advancing the cannula from the distal ascending aorta into the innominate artery. In 8 of 9 Norwood patients, LFCP was maintained by directing the arterial cannula into the pulmonary artery confluence and perfusing the innominate artery through the right modified Blalock-Taussig shunt fully constructed before cannulation for cardiopulmonary bypass. In 2 patients requiring isolated arch reconstruction, the ascending aorta was cannulated and the cross-clamp was applied just distal to the innominate artery. LFCP was maintained at 0.6 +/- 0.2 L x min(-1) x m(-2) for 41.0 +/- 13.9 minutes at 18.5 degrees C +/- 1.1 degrees C. In 10 of the 18 patients, blood pressure during LFCP was 15 +/- 8 mm Hg remote from the innominate artery (left radial, umbilical or femoral arteries). In 8 of the 18 patients, right radial pressure during LFCP was 24 +/- 10 mm Hg. The mean mixed-venous saturation was 79.8% +/- 10% during LFCP. Two patients had preoperative seizures, whereas none had seizures postoperatively. One patient died. Neonatal aortic arch reconstruction is possible without circulatory arrest or direct arch vessel cannulation. These techniques maintained adequate mixed-venous oxygen saturations with no associated adverse neurologic outcomes.

  15. Radiological management of multiple hepatic artery pseudoaneurysms associated with cholangitic abscesses

    International Nuclear Information System (INIS)

    Goyal, Ankur; Madhusudhan, Kumble S; Gamanagatti, Shivanand; Baruah, Bhaskar; Shalimar; Sharma, Raju

    2016-01-01

    Hepatic artery pseudoaneurysms (HAP) are uncommon, occurring mostly as a complication of trauma (accidental or iatrogenic). Liver abscess rarely causes HAP and multiple HAP associated with cholangitic abscesses have not been reported in the literature. We present a patient of acute necrotizing pancreatitis with stent block cholangitis and multiple cholangitic abscesses who developed hemorrhagic output through drainage catheter in the liver abscess. A multiphasic CT angiography demonstrated three HAP, which were treated with a combination of endovascular coil embolization and percutaneous thrombin injection. The fact that cholangitic abscesses may be associated with pseudoaneurysms should not be neglected, considering the potentially catastrophic complication and relatively easy radiological management. CT angiography permits accurate diagnosis and lays down the roadmap for endovascular procedures

  16. Radiological management of multiple hepatic artery pseudoaneurysms associated with cholangitic abscesses

    Directory of Open Access Journals (Sweden)

    Ankur Goyal

    2016-01-01

    Full Text Available Hepatic artery pseudoaneurysms (HAP are uncommon, occurring mostly as a complication of trauma (accidental or iatrogenic. Liver abscess rarely causes HAP and multiple HAP associated with cholangitic abscesses have not been reported in the literature. We present a patient of acute necrotizing pancreatitis with stent block cholangitis and multiple cholangitic abscesses who developed hemorrhagic output through drainage catheter in the liver abscess. A multiphasic CT angiography demonstrated three HAP, which were treated with a combination of endovascular coil embolization and percutaneous thrombin injection. The fact that cholangitic abscesses may be associated with pseudoaneurysms should not be neglected, considering the potentially catastrophic complication and relatively easy radiological management. CT angiography permits accurate diagnosis and lays down the roadmap for endovascular procedures.

  17. A case of gastrointestinal bleeding due to right hepatic artery pseudoaneurysm following total remnant pancreatectomy: A case report

    Directory of Open Access Journals (Sweden)

    Atsushi Fujio

    Full Text Available Introduction: Pseudoaneurysm is a serious complication after pancreatic surgery, which mainly depends on the presence of a preceding pancreatic fistula. Postpancreatectomy hemorrhage following total pancreatectomy is a rare complication due to the absence of a pancreatic fistula. Here we report an unusual case of massive gastrointestinal bleeding due to right hepatic artery (RHA pseudoaneurysm following total remnant pancreatectomy. Presentation of case: A 75-year-old man was diagnosed with intraductal papillary mucinous carcinoma recurrence following distal pancreatectomy and underwent total remnant pancreatectomy. After discharge, he was readmitted to our hospital with melena because of the diagnosis of gastrointestinal bleeding. Gastrointestinal endoscopy was performed to detect the origin of bleeding, but an obvious bleeding point could not be detected. Abdominal computed tomography demonstrated an expansive growth, which indicated RHA pseudoaneurysm. Emergency angiography revealed gastrointestinal bleeding into the jejunum from the ruptured RHA pseudoaneurysm. Transcatheter arterial embolization was performed; subsequently, bleeding was successfully stopped for a short duration. Because of improvements in his general condition, the patient was discharged. Discussion: To date, very few cases have described postpancreatectomy hemorrhage following total remnant pancreatectomy. We suspect that the aneurysm ruptured into the jejunum, possibly because of the scarring and inflammation associated with his two complex surgeries. Conclusion: Pseudoaneurysm should be considered when the fragility of blood vessels is suspected, despite no history of anastomotic leak and intra-abdominal abscess. Our case also highlighted that detecting gastrointestinal bleeding is necessary to recognize sentinel bleeding if the origin of bleeding is undetectable. Abbreviations: PPH, RHA, CT, IPMC, RCCs, POD, LHA, GIE, TAE, Keywords: Case report, Pseudoaneurysm, Total

  18. Mirizzi syndrome associated with hepatic artery pseudoaneurysm: a case report

    Directory of Open Access Journals (Sweden)

    Anderson Oliver

    2008-11-01

    Full Text Available Abstract Introduction This is the first case report of Mirizzi syndrome associated with hepatic artery pseudoaneurysm. Case presentation A 54-year-old man presented with painful obstructive jaundice and weight loss. Computed tomography showed a hilar mass in the liver. Following an episode of haemobilia, angiography demonstrated a pseudoaneurysm of a branch of the right hepatic artery that was embolised. At surgery, a gallstone causing Mirizzi type II syndrome was found to be responsible for the biliary obstruction and a necrotic inflammatory mass and haematoma were found to be extending into the liver. The mass was debrided and drained, the obstructing stones removed and the bile duct drained with a t-tube. The patient made a full recovery. Conclusion This case highlights another situation where there may be difficulty in differentiating Mirizzi syndrome from biliary tract cancer.

  19. [Change of paradigms in the surgical treatment of complex thoracic aortic disease].

    Science.gov (United States)

    Herold, Ulf; Tsagakis, Konstantinos; Kamler, Markus; Massoudy, Parwis; Assenmacher, Eva; Eggebrecht, Holger; Buck, Thomas; Jakob, Heinz

    2006-08-01

    One of the main issues in complex thoracic aortic disease, requiring the replacement of the ascending aorta, the entire aortic arch and the descending aorta, is the vast amount of surgery necessary to cure the patient. Though one-stage repair is feasible by a clamshell thoracotomy, the associated surgical trauma and perioperative morbidity limit this approach to younger patients only. Classic surgical repair consist of a two-stage strategy, whereby, in the first step, the ascending aorta and the aortic arch are replaced via a midline sternotomy. In the second step, via a lateral thoracotomy, the descending aorta is replaced. The two stages may sum up to a mortality of 20%; furthermore, the waiting period between the stages is associated with a mortality rate of 10% of its own. Additionally, the two-stage strategy has an inherent limitation, due to the comorbidity and advanced age of the majority of patients. Therefore, the second stage cannot be offered to up to 30% of patients. New developments and improvements in aortic surgery were introduced to overcome these shortcomings and to simplify the surgical repair. The "elephant trunk" principle, introduced by Borst et al. in 1983, was an important step to facilitate surgical repair, but still required the second step. With the introduction of endovascular repair of thoracic aortic disease with stent grafts implanted retrograde via the femoral artery, new therapeutic concepts emerged. In the late 1990s, two Japanese groups reported first trials to stabilize the free-floating "elephant trunk" prosthesis by implantation of nitinol stent grafts into the vascular graft. The applied devices were purely custom-made and nonstandardized. The availability of industrially made and CE-marked stent-graft devices raised the possibility to apply them in open aortic arch surgery. The experience with stent-graft devices implanted antegrade into the descending aorta (Medtronic Talent) was reported first by the Essen and the Vienna

  20. Over length quantification of the multiaxial mechanical properties of the ascending, descending and abdominal aorta using Digital Image Correlation.

    Science.gov (United States)

    Peña, Juan A; Corral, Victoria; Martínez, Miguel A; Peña, Estefanía

    2018-01-01

    In this paper, we hypothesize that the biaxial mechanical properties of the aorta may be dependent on arterial location. To demonstrate any possible position-related difference, our study analyzed and compared the biaxial mechanical properties of the ascending thoracic aorta, descending thoracic aorta and infrarenal abdominal aorta stemming from the same porcine subjects, and reported values of constitutive parameters for well-known strain energy functions, showing how these mechanical properties are affected by location along the aorta. When comparing ascending thoracic aorta, descending thoracic aorta and infrarenal abdominal aorta, abdominal tissues were found to be stiffer and highly anisotropic. We found that the aorta changed from a more isotropic to a more anisotropic tissue and became progressively less compliant and stiffer with the distance to the heart. We observed substantial differences in the anisotropy parameter between aortic samples where abdominal samples were more anisotropic and nonlinear than the thoracic samples. The phenomenological model was not able to capture the passive biaxial properties of each specific porcine aorta over a wide range of biaxial deformations, showing the best prediction root mean square error ε=0.2621 for ascending thoracic samples and, especially, the worst for the infrarenal abdominal samples ε=0.3780. The micro-structured model with Bingham orientation density function was able to better predict biaxial deformations (ε=0.1372 for ascending thoracic aorta samples). The root mean square error of the micro-structural model and the micro-structured model with von Mises orientation density function were similar for all positions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Management of hemorrhage secondary to a pseudoaneurysm of the ...

    African Journals Online (AJOL)

    We report the case of a 31-year-old man with chronic pancreatitis and haematemesis secondary to a gastroduodenal artery pseudoaneurysm. No evidence-based guidelines exist regarding the optimal treatment modality for this condition. In referring to this case, we emphasise the value of coeliac arteriography for ...

  2. Pseudoaneurysm of the occipital artery: an unusual cause of persisting headache after minor head injury.

    LENUS (Irish Health Repository)

    Aquilina, K

    2012-02-03

    Post-traumatic pseudoaneurysms of the extracranial arteries in the scalp are uncommon sequelae of head injury. We report on a patient who presented four weeks after a minor head injury with a tender, pulsating and enlarging mass in the course of the left occipital artery. There was associated headache radiating to the vertex. Computed tomographic angiography confirmed the lesion to be a pseudoaneurysm of the occipital artery. The lump was resected with complete resolution of symptoms.

  3. Role of contrast-enhanced helical CT in the evaluation of acute thoracic aortic injuries after blunt chest trauma

    International Nuclear Information System (INIS)

    Scaglione, M.; Pinto, A.; Pinto, F.; Romano, L.; Ragozzino, A.; Grassi, R.

    2001-01-01

    The purpose of this retrospective study was to determine the value of contrast-enhanced helical CT for detecting and managing acute thoracic aortic injury (ATAI). Between June 1995 and February 2000, 1419 consecutive chest CT examinations were performed in the setting of major blunt trauma. The following CT findings were considered indicative of ATAI: intimal flap; pseudoaneurysm; contour irregularity; lumen abnormality; and extravasation of contrast material. On the basis of these direct findings no further diagnostic investigations were performed. Isolated mediastinal hematoma on CT scans was considered an indirect sign of ATAI: In these cases, thoracic aortography was performed even if CT indicated normal aorta. Seventy-seven patients had abnormal CT scans: Among the 23 patients with direct CT signs, acute thoracic aortic injuries was confirmed at thoracotomy in 21. Two false-positive cases were observed. The 54 remaining patients had isolated mediastinal hematoma without aortic injuries at CT and corresponding negative angiograms. The 1342 patients with negative CT scans were included in the 8-month follow-up program and did not show any adverse sequela based on clinical and radiographic criteria. Contrast-enhanced helical CT has a critical role in the exclusion of thoracic aortic injuries in patient with major blunt chest trauma and prevents unnecessary thoracic aortography. Direct CT signs of ATAI do not require further diagnostic investigations to confirm the diagnosis: Isolated aortic bands or contour vessel abnormalities should be first considered as possible artifacts or related to non-traumatic etiologies especially when mediastinal hematoma is absent. In cases of isolated mediastinal hematoma other possible sources of bleeding should be considered before directing patients to thoracic aortography. (orig.)

  4. MYCOTIC FEMORAL PSEUDOANEURYSMS FROM INTRAVENOUS DRUG ABUSE

    Directory of Open Access Journals (Sweden)

    Vojko Flis

    2004-04-01

    Full Text Available Background. Parenteral drug abuse is the most common cause of infected femoral artery pseudoaneurysms (IFAP. This complication of intravenous drug abuse is not only limb threatening but can also be life threatening. The management of the IFAP is difficult and controversial. Generally speaking, ligation and excision of the pseudoaneurysm without revascularization is accepted procedure in majority of the patients. However it is not regarded as an appropriate procedure for cases where the high probability of amputation is expected from acute interruption of the femoral artery flow.Patients, methods and results. We present three cases of young (average 20 years, range 18–24 patients with IFAP, in which a primary reconstruction was performed due to absence of doppler signal over pedal arteries after ligation of common femoral artery. In two of them complications in form of haemorrhage and repeated infection developed in late postoperative period. The first one, had an excision and ligation while the second one had a reconstruction made by means of a silver impregnated dacron prosthesis. None of the patients required an amputation.Conclusions. Overall prognosis and prognosis of the reconstruction in parenteral drug abuse patients is uncertain because there is a high incidence of postoperative drug injection despite aggressive drug rehabilitation.

  5. Multi detector computed tomography (MDCT) of the aortic root; ECG-gated verses non-ECG-gated examinations

    International Nuclear Information System (INIS)

    Kristiansen, Joanna; Guenther, Anne; Aalokken, Trond Mogens; Andersen, Rune

    2011-01-01

    Purpose: Motion artifacts may degrade a conventional CT examination of the ascending aorta and hinder accurate diagnosis. We quantitatively compared retrospectively electrocardiographic (ECG) -gated multi detector computed tomography (MDCT) with non-ECG-gated MDCT in order to demonstrate whether or not one of the methods should be preferred. Method: The study included seventeen patients with surgically reconstructed aortic root and reimplanted coronary arteries. All patients had undergone both non-gated MDCT and retrospectively ECG-gated MDCT employing a stringently modulated tube current with single phase image reconstruction. The incidence of motion artifacts in the left main coronary artery (LM), proximal right coronary artery (RCA), and aortic root and ascending aorta were rated using a four point scale. The effective dose for each scan was calculated and normalized to a 15 cm scan length. Statistical analysis of motion artifacts and radiation dose was performed using Wilcoxon matched pairs signed rank sum test. Results: A significant reduction in motion artifacts was found in all three vessels in images from the retrospectively ECG-gated scans (LM: P = 0.005, RCA: P = 0.015, aorta: P = 0.003). The mean normalized effective radiation dose was 3.69 mSv (±1.03) for the non-ECG-gated scans and 16.37 mSv (±2.53) for the ECG-gated scans. Conclusion: Retrospective ECG-gating with single phase reconstruction significantly reduces the incidence of motion artifacts in the aortic root and the proximal portion of the coronary arteries but at the expense of a fourfold increase in radiation dose.

  6. Thoracoabdominal aortic aneurysm repair in patients with marfan syndrome.

    Science.gov (United States)

    Mommertz, G; Sigala, F; Langer, S; Koeppel, T A; Mess, W H; Schurink, G W H; Jacobs, M J

    2008-02-01

    We assessed the surgical outcome of descending thoracic aortic aneurysm repair (DTAA) and thoracoabdominal aortic aneurym (TAAA) repair in patients with Marfan syndrome. During a six year period, 206 patients underwent DTAA and TAAA repair. In 22 patients, Marfan syndrome was confirmed. The median age was 40 years with a range between 18 and 57 years. The extend of the aneurysms included 6 DTAA (1 with total arch, 2 with distal hemi-arch), 11 type II TAAA (2 with total arch, 3 with distal hemi-arch), 4 type III and one type IV TAAA. All patients suffered from previous type A (n=6) or type B (n=16) aortic dissection and 15 already underwent aortic procedures like Bentall (n=7) and ascending aortic replacement (n=8). All patients were operated on according to the standard protocol with cerebrospinal fluid drainage, distal aortic and selective organ perfusion and monitoring motor evoked potentials. In patients undergoing simultaneous arch replacement (via left thoracotomy), transcranial Doppler and EEG assessed cerebral physiology during antegrade brain perfusion. In four patients circulatory arrest under moderate hypothermia was required. In-hospital mortality did not occur. Major postoperative complications like paraplegia, renal failure, stroke and myocardial infarction were not encountered. Mean pre-operative creatinine level was 125mmol/L, which peaked to a mean maximal level of 130 and returned to 92mmol/L at discharge. Median intubation time was 1.5 days (range 0.33-30 days). Other complications included bleeding requiring surgical intervention (n=1), arrhythmia (n=2), pneumonia (n=2) and respiratory distress syndrome (n=1). At a median follow-up of 38 months all patients were alive. Using CT surveillance, new or false aneurysms were not detected, except in one patient who developed a visceral patch aneurysm six years after open type II repair. Surgical repair of descending and thoracoabdominal aortic aneurysms provides excellent short- and mid-term results in

  7. Aortic dissection presenting with secondary pulmonary hypertension caused by compression of the pulmonary artery by dissecting hematoma: a case report

    International Nuclear Information System (INIS)

    Kim, Dong Hun; Ryu, Sang Wan; Choi, Yong Sun; Ahn, Byoung Hee

    2004-01-01

    The rupture of an acute dissection of the ascending aorta into the space surrounding the pulmonary artery is an uncommon occurrence. No previous cases of transient pulmonary hypertension caused by a hematoma surrounding the pulmonary artery have been documented in the literature. Herein, we report a case of acute aortic dissection presenting as secondary pulmonary hypertension

  8. Endovascular Treatment of Anastomotic Pseudoaneurysms after Aorto-iliac Surgical Reconstruction

    International Nuclear Information System (INIS)

    Lagana, Domenico; Carrafiello, Gianpaolo; Mangini, Monica; Recaldini, Chiara; Lumia, Domenico; Cuffari, Salvatore; Caronno, Roberto; Castelli, Patrizio; Fugazzola, Carlo

    2007-01-01

    Purpose. To assess the effectiveness of endovascular treatment of anastomotic pseudoaneurysms (APAs) following aorto-iliac surgical reconstruction. Materials. We retrospectively evaluated 21 men who, between July 2000 and March 2006, were observed with 30 APAs, 13 to the proximal anastomosis and 17 to the distal anastomosis. The patients had had previous aorto-iliac reconstructive surgery with a bypass due to aneurysm (15/21) or obstructive disease (6/21). The following devices were used: 12 bifurcated endoprostheses, 2 aorto-monoiliac, 4 aortic extenders, 1 stent-graft leg, and 2 covered stents. Follow-up was performed with CT angiography at 1, 3, and 6 months after the procedure and yearly thereafter. Results. Immediate technical success was 100%. No periprocedural complications occurred. Four patients died during follow-up from causes not related to APA, and 1 (treated for prosthetic-enteric fistula) from sepsis 3 months after the procedure. During a mean follow-up of 19.7 months (range 1-72 months), 2 of 21 occlusions of stent-graft legs occurred 3 and 24 months after the procedure (treated with thrombolysis and percutaneous transluminal angioplasty and femorofemoral bypass, respectively) and 1 type I endoleak. Primary clinical success rate was 81% and secondary clinical success was 91%. Conclusion. Endovascular treatment is a valid alternative to open surgery and can be proposed as the treatment of choice for APAs, especially in patients who are a high surgical risk. Further studies with larger series and longer follow-up are necessary to confirm the long-term effectiveness of this approach

  9. Pseudoaneurysm of the posterior circumflex humeral artery diagnosed by sonography

    DEFF Research Database (Denmark)

    Damgaard, Bodil; Court-Payen, Michel; Larsen, Lone

    2009-01-01

    with a painless, nonpulsatile mass in the posterior shoulder region and was suspected of a malignant soft-tissue tumor. Sonography, including power Doppler imaging, demonstrated a pseudoaneurysm, with the intralesional blood-filled cavity developed from the posterior circumflex humeral artery. The diagnosis...

  10. Intrarenal pseudoaneurysm after percutaneous nephrolithotomy: angiotomographic assessment and endovascular management

    Directory of Open Access Journals (Sweden)

    M. F. Massulo-Aguiar

    2006-08-01

    Full Text Available We report a case of intrarenal pseudoaneurysm of the right kidney after percutaneous nephrolithotomy (PCNL in supine position. Diagnosis was established by angiotomography with a 3-D reconstruction. Treatment was successfully achieved by endovascular occlusion using N-butyl-2-cyanoacrylate.

  11. Pseudoaneurysm of the Internal Carotid Artery: Treatment with a Covered Stent

    International Nuclear Information System (INIS)

    Scavee, Vincent; Wispelaere, Jean-Francois de; Mormont, Eric; Coulier, Bruno; Trigaux, Jean-Paul; Schoevaerdts, Jean-Claude

    2001-01-01

    Dissection of the cervical segment of the internal carotid artery may occur spontaneously or after trauma. We report the management of a 53-year-old right-handed man with progressive dizziness and neck pain 6 weeks after a motor vehicle collision. The clinical and neurologic examinations were normal. The CT scan led to the diagnosis of a pseudoaneurysm of the right internal carotid artery near the skull base. We successfully treated this post-traumatic lesion with a covered stent. The patient underwent the endovascular procedure under general anesthesia and transcranial Doppler monitoring. No neurologic event was observed. Obliteration of the pseudoaneurysm with preservation of the carotid artery was achieved. The patient was discharged from the hospital 72 hr later with no complications. Clinical and imaging follow-up at 6 months was unremarkable

  12. Successful surgical repair of acute type A aortic dissection without the use of blood products.

    Science.gov (United States)

    Papalexopoulou, N; Attia, R Q; Bapat, V N

    2013-10-01

    We report successful surgical treatment of type A aortic dissection in a Jehovah's Witness without the use of any blood products. An interposition graft replacement of the ascending aorta was carried out. This was under right axillo-atrial cardiopulmonary bypass with antegrade cerebral perfusion via right a subclavian and left carotid cannula for 24 minutes at 28°C. Body temperature was kept at 32°C throughout. Autologous transfusion was deployed using cell salvage and a preoperative haemodilution technique. The patient was given tranexamic acid, desmopressin, recombinant factor VIIa, folic acid and epoetin alfa. Patients who object to transfusion represent a significant challenge, especially those who are at a high risk of coagulopathy associated with inherent aortic dissection leading to perturbed haemodynamics, cardiopulmonary bypass and hypothermic circulatory arrest. Type A aortic dissection repair is possible in patients refusing the use of blood products with blood salvage techniques and synthetic products that can limit the risk of bleeding. Minimal hypothermia is vital to preserve platelet function and avoid coagulopathy. Thus, a combination of normothermic/minimal hypothermia and antegrade cerebral protection with a blood conservation strategy can be deployed for a successful surgical outcome in aortic dissection without transfusion.

  13. Primary Infrarenal Aortic Stenting With or Without Iliac Stenting for Isolated and Aortoiliac Stenoses: Single-Centre Experience With Long-Term Follow-Up

    Energy Technology Data Exchange (ETDEWEB)

    Tapping, C. R.; Ahmed, M.; Scott, P. M.; Lakshminarayan, R.; Robinson, G. J.; Ettles, D. F.; Shrivastava, V., E-mail: vivek.shrivastava@hey.nhs.uk [Hull Royal Infirmary, Hull and East Yorkshire Hospitals NHS Trust, Department of Radiology (United Kingdom)

    2013-02-15

    The purpose of this study was to evaluate the technical success, complications, long-term clinical outcome, and patency after primary infrarenal aortic stenting for aortic and aortoiliac stenosis. Between January 1999 and January 2006, 22 consecutive patients underwent endovascular treatment because of infrarenal aortic stenosis with and without common iliac stenosis (10 men; mean age 64 {+-} 14 years). Eleven (11 of 22) patients had an isolated aortic stenosis, whereas 11 of 22 had aortic stenosis that extended into the common iliac arteries (CIAs). Thirteen patients were Rutherford classification type 3, and 9 patients were type 4. Statistical analysis included paired Student t test and Kaplan-Meier life table analysis; p < 0.05 was considered significant. Technical and initial clinical success was achieved in all patients. There were three (14 %) procedure-related complications, which included two access-point pseudoaneurysms and one non-flow-limiting left external iliac dissection. Patients were followed-up for a mean period of 88 months (range 60-132). Mean preprocedure ankle brachial pressure indexes (ABPI) were 0.60 {+-} -0.15 (right) and 0.61 {+-} -0.16 (left). After the procedure they were 0.86 {+-} -0.07 (right) and 0.90 {+-} -0.09 (left). The increase in ABPI was significant (p < 0.05), and this continued throughout follow-up. Four (18 %) patients had recurrence of symptoms during follow-up. These occurred at 36, 48, 48, and 50 months after the original procedure. All four patients were successfully treated with repeat angioplasty procedures. There was a significant difference in primary patency between isolated aortic stenosis (100 %) and aortoiliac stenosis (60 %) (p = 0.031). Cumulative follow-up was 1920 months yielding a reintervention rate of 0.025/events/year. Primary stenting of infrarenal stenosis is safe and successful with a low reintervention rate. It should be considered as first-line treatment for patients with infrarenal aortic stenotic

  14. [Brachial artery pseudoaneurysm: a rare but serious complication in hemodialysis patients with arteriovenous fistula].

    Science.gov (United States)

    Mancini, Andrea; Castriotta, Giuseppe; Angelini, Pernina; Bozzi, Michele; Giancaspro, Vincenzo; La Raia, Elvira; Nisi, Maria Teresa; Proscia, Anna Rita; Tarantino, Giuseppe; Vitale, Ottavia; Cuzzola, Cristoforo

    2017-06-01

    A pseudoaneurysm or false aneurysm of the brachial artery is an uncommon occurrence in patients receiving hemodialysis with arteriovenous fistula (AVF). We describe the case of a 76-year-old woman presenting with a large, tender, pulsatile mass in the right antecubital region 10 cm from the AVF. B-mode ultrasound examination revealed a saccular hematoma. Color doppler showed a recirculation movement of blood, creating a two colors image called "Korean flag". The patient was transferred to the surgical unit where she first underwent ultrasound-guided compression and then surgical repair of the pseudoaneurysm. Two weeks after surgery the AVF was used again as an access for hemodialysis. Differentiating between a false and a true aneurysm based on ultrasound is not always straightforward. Doppler ultrasound findings can be decisive for the early diagnosis of a pseudoaneurysm to ensure proper treatment planning given the dangerous complications of ruptures. Treatment options include: compression, percutaneous thrombin injection, endovascular exclusion with covered stents, aneurysmectomy and surgical repair. Copyright by Società Italiana di Nefrologia SIN, Rome, Italy.

  15. Ultrasound-Guided Thrombin Injection Is a Safe and Effective Treatment for Femoral Artery Pseudoaneurysm in the Morbidly Obese.

    Science.gov (United States)

    Yoo, Taehwan; Starr, Jean E; Go, Michael R; Vaccaro, Patrick S; Satiani, Bhagwan; Haurani, Mounir J

    2017-08-01

    Ultrasound-guided thrombin injection (UGTI) is a well-established practice for the treatment of femoral artery pseudoaneurysm. This procedure is highly successful but dependent on appropriate pseudoaneurysm anatomy and adequate ultrasound visualization. Morbid obesity can present a significant technical challenge due to increased groin adiposity, resulting in poor visualization of critical structures needed to safely perform the procedure. We aim to evaluate the safety and efficacy of UGTI to treat femoral artery pseudoaneurysm in the morbidly obese. This is a retrospective cohort study in which all patients who underwent UGTI at The Ohio State University Ross Heart Hospital from 2009 to 2014 were analyzed for patient characteristics and stratified by body mass index (BMI). Patients with BMI ≥ 35 were considered morbidly obese and were compared to patients with a BMI injection. There were 41 nonmorbidly obese and 13 morbidly obese patients. Mean age was 64.5 years. The cohort was 44.4% male. There were 6 failures, of which 1 underwent successful repeat injection and 5 underwent open surgical repair. There was no statistically significant difference in failure between nonmorbidly obese and morbidly obese patients (9.8% vs 15.4%, P = .45). There were no embolic/thrombotic complications. Ultrasound-guided thrombin injection is a safe and effective therapy in the morbidly obese for the treatment of femoral artery pseudoaneurysm. In the hands of experienced sonographers and surgeons with adequate visualization of the pseudoaneurysm sac, UGTI should remain a standard therapy in the morbidly obese.

  16. Management of an elderly patient with respiratory failure due to double aortic arch

    Directory of Open Access Journals (Sweden)

    Changwan Ryu

    2016-01-01

    Full Text Available Vascular rings are congenital malformations of the aortic arch. A double aortic arch (DAA, the most common type of vascular ring, results from the failure of the fourth embryonic branchial arch to regress, leading to an ascending aorta that divides into a left and right arch that fuse together to completely encircle the trachea and esophagus. The subsequent DAA causes compressive effects on the trachea and esophagus that typically manifests in infancy or early childhood. Adult presentations, particularly in the elderly, are exceedingly rare. Historically such patients have a long-standing history of dyspnea on exertion and dysphagia, with many assumed to have obstructive lung or intrinsic cardiac disease. We describe a case of an elderly woman who presented with respiratory failure due to DAA. In her case, surgery was not feasible and we describe our experience with airway stenting.

  17. Endothelin-1 overexpression exacerbates atherosclerosis and induces aortic aneurysms in apolipoprotein E knockout mice.

    Science.gov (United States)

    Li, Melissa W; Mian, Muhammad Oneeb Rehman; Barhoumi, Tlili; Rehman, Asia; Mann, Koren; Paradis, Pierre; Schiffrin, Ernesto L

    2013-10-01

    Endothelin (ET)-1 plays a role in vascular reactive oxygen species production and inflammation. ET-1 has been implicated in human atherosclerosis and abdominal aortic aneurysm (AAA) development. ET-1 overexpression exacerbates high-fat diet-induced atherosclerosis in apolipoprotein E(-/-) (Apoe(-/-)) mice. ET-1-induced reactive oxygen species and inflammation may contribute to atherosclerosis progression and AAA development. Eight-week-old male wild-type mice, transgenic mice overexpressing ET-1 selectively in endothelium (eET-1), Apoe(-/-) mice, and eET-1/Apoe(-/-) mice were fed high-fat diet for 8 weeks. eET-1/Apoe(-/-) had a 45% reduction in plasma high-density lipoprotein (P<0.05) and presented ≥ 2-fold more aortic atherosclerotic lesions compared with Apoe(-/-) (P<0.01). AAAs were detected only in eET-1/Apoe(-/-) (8/21; P<0.05). Reactive oxygen species production was increased ≥ 2-fold in perivascular fat, media, or atherosclerotic lesions in the ascending aorta and AAAs of eET-1/Apoe(-/-) compared with Apoe(-/-) (P<0.05). Monocyte/macrophage infiltration was enhanced ≥ 2.5-fold in perivascular fat of ascending aorta and AAAs in eET-1/Apoe(-/-) compared with Apoe(-/-) (P<0.05). CD4(+) T cells were detected almost exclusively in perivascular fat (3/6) and atherosclerotic lesions (5/6) in ascending aorta of eET-1/Apoe(-/-) (P<0.05). The percentage of spleen proinflammatory Ly-6C(hi) monocytes was enhanced 26% by ET-1 overexpression in Apoe(-/-) (P<0.05), and matrix metalloproteinase-2 was increased 2-fold in plaques of eET-1/Apoe(-/-) (P<0.05) compared with Apoe(-/-). ET-1 plays a role in progression of atherosclerosis and AAA formation by decreasing high-density lipoprotein, and increasing oxidative stress, inflammatory cell infiltration, and matrix metalloproteinase-2 in perivascular fat, vascular wall, and atherosclerotic lesions.

  18. Thoracic aortic stent-graft placement combined with left subclavian artery 'chimney operation': therapeutic analysis of 15 cases with insufficient proximal anchor area

    International Nuclear Information System (INIS)

    Liu Jiayi; Huang Lianjun; Fan Zhanming; Zhang Zhaoqi

    2012-01-01

    Objective: To discuss the strategies for the management of insufficient proximal anchoring area during the performance of transluminal stent-graft placement (TSGP), and to evaluate the feasibility of intentional coverage of the left subclavian artery (LSA) together with left subclavian artery stent-graft placement by using 'chimney operation' technique. Methods: A total of 15 patients with thoracic aortic diseases complicated by insufficient proximal anchoring area, who were encountered in authors' hospital during the period from Dec. 2009 to April 2011, were enrolled in this study. The clinical data were retrospectively analyzed. The thoracic aortic diseases included aortic dissection (n=6), aortic pseudoaneurysm (n=1), aortic aneurysm (n=4) and penetrating ulcer (n=4). Of the 15 patients, the distance between the lesion and LSA anchoring site 15 mm in 2. TSGP was carried out. The ostium of LSA was intentionally and completely covered by thoracic aortic stent-graft and left subclavian artery stent-graft placement was subsequently performed. The patients were kept under observation for symptoms of cerebral and upper limb ischemia. The postoperative complications such as endoleak and the patency of LSA were assessed with angiography. Results: Thoracic aortic stent-graft placement was successfully carried out in all 15 patients. In addition, one 'chimney' stent was properly implanted in LSA in each patient. After the procedure, no complications of nervous system or severe ischemia of upper extremity occurred. Follow-up examinations performed between 5 days to 3 months after the treatment revealed that the aortic stent-graft remained in stable condition and no type Ⅰ endoleak occurred, meanwhile the blood flow in 'chimney' stent was unobstructed. Conclusion: Intentional LSA coverage with 'chimney operation' can expand the applicability of TSGP with high tolerability. It is especially useful for patients with left vertebral artery blood supply dominance or with

  19. Standing tall after DeBakey Type I aortic dissection extending to left iliac artery

    Science.gov (United States)

    Natarajan, Deepak; Natarajan, Nalin

    2015-01-01

    This report describes DeBakey Type I aortic dissection in a middle-aged hypertensive female who had undergone mitral tissue valve replacement a decade previously. The patient had severe abrupt onset tearing pain in her throat, back, and chest, for which she got admitted in a community hospital, where because of no changes in her ECG and biomarkers, the dissection of aorta was missed. She was subjected to coronary angiography more than 6 weeks later for pain in her left shoulder, which demonstrated normal vessels. She then underwent multi-detector computerised tomography aortogram (MD CTA) that revealed aortic dissection involving ascending, the arch, and descending thoracic and abdominal aorta. The patient declined surgical intervention and has been provided medical therapy in the form of high dose oral beta-blocker and losartan. The patient continues to be stable for the past 18 weeks since the index event. The report highlights the importance of detecting aortic dissection by keeping high index of clinical suspicion in a patient with abrupt onset tearing pain in the throat/back and employment of MD CTA. PMID:26702700

  20. Standing tall after DeBakey Type I aortic dissection extending to left iliac artery

    Directory of Open Access Journals (Sweden)

    Deepak Natarajan

    2015-11-01

    Full Text Available This report describes DeBakey Type I aortic dissection in a middle-aged hypertensive female who had undergone mitral tissue valve replacement a decade previously. The patient had severe abrupt onset tearing pain in her throat, back, and chest, for which she got admitted in a community hospital, where because of no changes in her ECG and biomarkers, the dissection of aorta was missed. She was subjected to coronary angiography more than 6 weeks later for pain in her left shoulder, which demonstrated normal vessels. She then underwent multi-detector computerised tomography aortogram (MD CTA that revealed aortic dissection involving ascending, the arch, and descending thoracic and abdominal aorta. The patient declined surgical intervention and has been provided medical therapy in the form of high dose oral beta-blocker and losartan. The patient continues to be stable for the past 18 weeks since the index event. The report highlights the importance of detecting aortic dissection by keeping high index of clinical suspicion in a patient with abrupt onset tearing pain in the throat/back and employment of MD CTA.

  1. Identification of Reference Genes for Quantitative Real Time PCR Assays in Aortic Tissue of Syrian Hamsters with Bicuspid Aortic Valve.

    Science.gov (United States)

    Rueda-Martínez, Carmen; Fernández, M Carmen; Soto-Navarrete, María Teresa; Jiménez-Navarro, Manuel; Durán, Ana Carmen; Fernández, Borja

    2016-01-01

    Bicuspid aortic valve (BAV) is the most frequent congenital cardiac malformation in humans, and appears frequently associated with dilatation of the ascending aorta. This association is likely the result of a common aetiology. Currently, a Syrian hamster strain with a relatively high (∼40%) incidence of BAV constitutes the only spontaneous animal model of BAV disease. The characterization of molecular alterations in the aorta of hamsters with BAV may serve to identify pathophysiological mechanisms and molecular markers of disease in humans. In this report, we evaluate the expression of ten candidate reference genes in aortic tissue of hamsters in order to identify housekeeping genes for normalization using quantitative real time PCR (RT-qPCR) assays. A total of 51 adult (180-240 days old) and 56 old (300-440 days old) animals were used. They belonged to a control strain of hamsters with normal, tricuspid aortic valve (TAV; n = 30), or to the affected strain of hamsters with TAV (n = 45) or BAV (n = 32). The expression stability of the candidate reference genes was determined by RT-qPCR using three statistical algorithms, GeNorm, NormFinder and Bestkeeper. The expression analyses showed that the most stable reference genes for the three algorithms employed were Cdkn1β, G3pdh and Polr2a. We propose the use of Cdkn1β, or both Cdkn1β and G3pdh as reference genes for mRNA expression analyses in Syrian hamster aorta.

  2. Identification of Reference Genes for Quantitative Real Time PCR Assays in Aortic Tissue of Syrian Hamsters with Bicuspid Aortic Valve.

    Directory of Open Access Journals (Sweden)

    Carmen Rueda-Martínez

    Full Text Available Bicuspid aortic valve (BAV is the most frequent congenital cardiac malformation in humans, and appears frequently associated with dilatation of the ascending aorta. This association is likely the result of a common aetiology. Currently, a Syrian hamster strain with a relatively high (∼40% incidence of BAV constitutes the only spontaneous animal model of BAV disease. The characterization of molecular alterations in the aorta of hamsters with BAV may serve to identify pathophysiological mechanisms and molecular markers of disease in humans. In this report, we evaluate the expression of ten candidate reference genes in aortic tissue of hamsters in order to identify housekeeping genes for normalization using quantitative real time PCR (RT-qPCR assays. A total of 51 adult (180-240 days old and 56 old (300-440 days old animals were used. They belonged to a control strain of hamsters with normal, tricuspid aortic valve (TAV; n = 30, or to the affected strain of hamsters with TAV (n = 45 or BAV (n = 32. The expression stability of the candidate reference genes was determined by RT-qPCR using three statistical algorithms, GeNorm, NormFinder and Bestkeeper. The expression analyses showed that the most stable reference genes for the three algorithms employed were Cdkn1β, G3pdh and Polr2a. We propose the use of Cdkn1β, or both Cdkn1β and G3pdh as reference genes for mRNA expression analyses in Syrian hamster aorta.

  3. Complete Remission of Pancreatic Pseudoaneurysm Rupture with Arterial Embolization in a Patient with Poor Risk for Surgery: A Case Report

    Directory of Open Access Journals (Sweden)

    Kuang-En Chu

    2012-05-01

    Full Text Available Pancreatic pseudoaneurysm is a rare vascular complication of chronic pancreatitis resulting from erosion of the pancreatic or peripancreatic artery into a pseudocyst that is identified as a pulsating vascular malformation which may lead to lethal complications if left untreated. Many publications in the literature consider angiography as the first step in the management of pancreatic pseudoaneurysm to stabilize the patient’s critical condition; it should be followed by surgical intervention as the definite treatment. We report a rare case of pancreatic pseudoaneurysm rupture with hemodynamic embarrassment in a critical patient with multiple comorbid conditions and poor risk for surgery who responded dramatically to angiographic management as a single therapeutic modality without further surgical intervention. The results observed in our patient suggest that pancreatic pseudoaneurysm may be successfully managed with angiography only and that not all cases require surgical intervention. This is particularly relevant in critically ill patients in whom surgical intervention would be unfeasible.

  4. Single-center mid-term experience with chimney-graft technique for the preservation of flow to the supra-aortic branches.

    Science.gov (United States)

    Shahverdyan, Robert; Mylonas, Spyridon; Gawenda, Michael; Brunkwall, Jan

    2018-04-01

    Objectives To investigate the feasibility and the mid-term outcomes of the chimney-graft technique for the revascularization of supra-aortic branches in patients with thoracic aortic pathologies involving the aortic arch. Methods A retrospective analysis of a prospectively maintained database between January 2010 and July 2016 was performed. Primary endpoints were 30-day and overall mortality. Secondary endpoints were technical success, target vessel patency, stroke/transitory ischemic attack and type I/III endoleak rate. Results A total of 30 patients (80% male, median age 70.0 years) were treated using the chimney-graft technique for the supra-aortic branches. The indication was a degenerative aneurysm in nine patients (32%) and a type B Stanford aortic dissection and a penetrating aortic ulcer in the descending aorta in seven patients (23%), respectively. In six patients (20.0%), the indication was an type Ia endoleak after previous endovascular thoracic repair, whereas a pseudoaneurysm after previous open repair of the descending aorta was the indication in one patient (3%). Twenty-three patients (77%) were treated electively, five (17%) emergently and two (7%) urgently because of free rupture. Technical success was achieved in 90% of patients. The 30-day/in-hospital mortality was 17% (5/30). A retrograde dissection was presented in five patients. Four patients experienced a cerebrovascular event. Eight patients had type Ia endoleak and 10 had type II. During the median follow-up of 16 months (range: 0-56), four further patients died: one in respiratory insufficiency, one due to a ruptured abdominal aortic aneurysm, one in meningitis and the last one for unknown reason. The chimney-graft patency was 100%. According to the Kaplan-Meier curve, the estimated survival at one year was 66 ± 9%. Conclusions The chimney-graft technique, despite a technically demanding strategy, is a useful tool as bailout procedure in our armamentarium for high-risk patients

  5. Successful endovascular treatment of a hemodialysis graft pseudoaneurysm by covered stent and direct percutaneous thrombin injection.

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2011-07-25

    Vascular access for hemodialysis remains a challenge for nephrologists, vascular surgeons, and interventional radiologists alike. Arteriovenous fistula and synthetic grafts remain the access of choice for long-term hemodialysis; however, they are subject to complications from infection and repeated needle cannulation. Pseudoaneurysms are an increasingly recognized adverse event. At present, there are many minimally invasive methods to repair these wall defects. We present a graft pseudoaneurysm, which required a combination of endovascular stent graft placement and percutaneous thrombin injection for successful occlusion.

  6. Iliac artery pseudoaneurysm after lumbar disc hernia operation

    Directory of Open Access Journals (Sweden)

    Mehmet Atay

    2016-03-01

    Full Text Available Lumbar disc herniation surgery is usually performed through a posterior approach. Vascular injuries can be counted among the complications. 39 years old male patient had lower extremity pain which has started after lumbar disc herniation surgery and continued for a month. Iliac arterial pseudoaneurysm has been detected in computerized tomography. It was successfully treated with vascular surgery [Cukurova Med J 2016; 41(0.100: 5-7

  7. Pseudoaneurysm Accompanied by Crowe Type IV Developmental Dysplasia of the Hip: A Case Report

    Directory of Open Access Journals (Sweden)

    Hirotake Yo

    2012-01-01

    Full Text Available We report the case of a 72-year-old woman whose pseudoaneurysm was difficult to diagnose and treat. The patient had a history of congenital dislocated hip and was undergoing anticoagulation therapy with warfarin due to the mitral valve replacement. Her chief complaint was pain and enlargement of the left buttock, and the laboratory tests revealed severe anemia. However, her elderly depression confused her chief complaint, and she was transferred to a psychiatric hospital. Two months after the onset of the symptoms, she was finally diagnosed with a pseudoaneurysm by contrast-enhanced CT and angiography. IDC coils were used for embolization. A plain CT showed hemostasis as well as a reduced hematoma at 2 months after the embolization. The possible contributing factors for the pseudoaneurysm included bleeding due to warfarin combined with an intramuscular hematoma accompanied by Crowe type IV developmental dysplasia of the hip that led to an arterial rupture by impingement between pelvis and femoral head. Since the warfarin treatment could not be halted due to the valve replacement, embolization was chosen for her treatment, and the treatment outcome was favorable.

  8. Huge femoral artery pseudoaneurysm in a patient with Behçet’s disease

    Directory of Open Access Journals (Sweden)

    Tarlaan Hasanaghaei

    2017-10-01

    Conclusion: Arterial pseudoaneurysm is life-threatening in BD and should be kept in mind to prevent major complications. Vascular involvement in BD patients is probably associated with hyperhomocysteinemia.

  9. Aortitis requiring aortic repair associated with glaucoma, thyroiditis, glaucoma, and neuropathy: case report

    Directory of Open Access Journals (Sweden)

    Bayer Günther

    2011-05-01

    Full Text Available Abstract Aortitis may be due to infectious and non-infectious causes. We observed aortitis, associated with glaucoma, thyroiditis, pericarditis, pleural effusion and neuropathy in a 63-years old woman. Despite antibiotic therapy, inflammatory signs persisted and resolved only after initiation of glucocorticoid therapy. Increasing aortic ectasia necessitated resection of the ascending aorta and implantation of a Vascutek 30 mm prosthesis. Histologically a granulomatous aortitis was diagnosed. Since all other possible causes were excluded, an immunological mechanism of the aortitis is suspected and possible triggering factors are discussed.

  10. Pseudoaneurysm of the Anterior Tibial Artery following Tibio-Talar-Calcaneum Fusion with a Retrograde Nail: A Rare Case and Literature Review

    Directory of Open Access Journals (Sweden)

    Simon Craxford

    2013-01-01

    Full Text Available This study reports the case of an 87-year-old woman who presented with a nonresolving haematoma 13 weeks following tibiotalar arthrodesis surgery on her right ankle using a retrograde nail. This was revealed by angiography to be a pseudoaneurysm of the anterior tibial artery. The patient subsequently underwent endovascular stenting of the pseudoaneurysm and has had a successful recovery. This case highlights the need for awareness of both the normal arterial supply to the leg and ankle as well as the potential for anatomical variations. Arterial variation may be as high as 6.7% based on published findings from cadaveric studies. As pseudoaneurysm is a rare complication, a high index of suspicion is needed in order to avoid a missed or delayed diagnosis. We urge surgeons to keep in mind the potential for pseudoaneurysm when a patient presents with a nonresolving haematoma and arrange appropriate further investigations as needed.

  11. Vascular geometry as a risk factor for non-penetrating traumatic injuries of the aortic arch.

    Directory of Open Access Journals (Sweden)

    Andreas Schicho

    Full Text Available To assess biomechanical factors in aortic arch geometry contributing to the development of non-penetrating aortic arch injury (NAAI in multiply injured patients with an Injury Severity Score (ISS ≥ 16.230 consecutive multiply injured trauma patients with an ISS ≥ 16 admitted to our Level-I trauma center during a consecutive 24-month period were prospectively included of whom 13 presented with NAAI (5.7%. Standardized whole-body CT in a 2x128-detector-row scanner included a head-and-neck CTA. Aortic arch diameters, width, height, angles and thoracic width and height were measured in individuals with NAAI and ISS-, sex-, age-, and trauma mechanism-matched controls.There was no difference between groups regarding sex, age, ISS, and aortic diameters. The aortic arch angle in individuals with NAAI (71.3° ± 14.9° was larger than in healthy control (60.7° ± 8.6°; p*<0.05. In patients with NAAI, the distance between ascendent and descendent aorta was larger (5.2 cm ± 1.9 cm than in control (2.8 ± 0.5 cm; ***p<0.001. The aortic arch is higher above tracheal bifurcation in NAAI (3.6 cm ± 0.6 cm than in matched control (2.4 cm ± 0.3 cm; ***p<0.001. Accordingly, the area under the aortic arch, calculated as half of an eliptic shape, is significantly larger in patients with NAAI (15.0 cm2 ± 6.5 cm2 when compared to age- and sex-matched controls without NAAI (5.5 cm2 ± 1.3 cm2; ***p<0.001.Besides the magnitude of deceleration and direction of impact, width and height of the aortic arch are the 3rd and 4th factor directly contributing to the risk of developing traumatic NAAI in severely injured patients.

  12. Diagnostic and therapy of acute thoracic aortic diseases; Diagnostik und Therapie akuter Erkrankungen der thorakalen Aorta

    Energy Technology Data Exchange (ETDEWEB)

    Schotten, Sebastian; Pitton, Michael B. [Universitaetsmedizin Mainz Univ. (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie

    2017-09-15

    Acute diseases of the thoracic aorta represent a relatively rare but life threatening spectrum of pathologies. The non-traumatic diseases are usually summarized by the term ''acute aortic syndrome''. A timely diagnosis and initiation of therapy are cornerstones for the patient outcome. CT has become the standard imaging procedure due do its widespread availability and excellent sensitivity. Furthermore, CT is able to discriminate the variants of acute aortic diseases and to detect the wide spectrum of complications. The volumetric CT dataset is also the basis for planning of interventional procedures. Open surgical repair still represents the standard of care for acute pathologies of the ascending aorta while endovascular therapy, due to minimally invasive character and good outcome, has replaced open surgery in most cases of complicated lesions of the descending aorta.

  13. [Redo ascending aorta replacement using a homograft for graft infection caused by methicillin-resistant Staphylococcus aureus; report of an emergently air-transferred case just after Great East Japan Earthquake].

    Science.gov (United States)

    Nakamura, Ken; Uchida, Tetsuro; Yoshimura, Yukihiro; Kim, Cholsu; Maekawa, Yoshiyuki; Minagawa, Tadanori; Mizumoto, Masahiro; Yamashita, Atsushi; Sadahiro, Mitsuaki; Saiki, Yoshikatsu; Kawamoto, Shunsuke

    2012-10-01

    We describe a case of replacement with a cryopreserved homograft for graft infection. A 48-year-old man had been performed ascending aorta replacement using woven dacron graft for type A aortic dissection. Two months ago, methicillin-resistant Staphylococcus aureus infection was suspected because of high-grade fever. Computed tomography (CT) scan revealed abscess formation around the prosthetic graft and redo operation using cryopreserved homograft was scheduled to avoid re-infection into mediastinum at Tohoku University Hospital, an institute cooperating with University of Tokyo tissue bank. However, Catastrophic Great East Japan Earthquake occurred the day before the scheduled date, and the patient could not have an operation at the institution. He was transferred to our hospital by helicopter. Then homograft was successfully implanted in ascending aorta after complete excision of infectious graft.

  14. Treatment of Cervical Internal Carotid Artery Spontaneous Dissection with Pseudoaneurysm and Unilateral Lower Cranial Nerves Palsy by Two Silk Flow Diverters

    Energy Technology Data Exchange (ETDEWEB)

    Zelenak, Kamil, E-mail: zelenak@unm.sk [University Hospital, Department of Radiology (Slovakia); Zelenakova, Jana [University Hospital, Department of Neurology (Slovakia); DeRiggo, Julius [University Hospital, Department of Neurosurgery (Slovakia); Kurca, Egon; Kantorova, Ema [University Hospital, Department of Neurology (Slovakia); Polacek, Hubert [University Hospital, Department of Radiology (Slovakia)

    2013-08-01

    Internal carotid artery (ICA) lesions in the parapharyngeal space (a dissection and a pseudoaneurysm) may present as isolated lower cranial nerves (IX, X, XI, and XII) palsy (Collet-Sicard syndrome). Some arteriopathies such as fibromuscular dysplasia and tortuosity make a vessel predisposed to dissection. Extreme vessel tortuosity makes the treatment by a stent graft impossible. Two Silk stents were used in a 46 year-old man with left lower cranial nerves (IX-XII) palsy for the treatment of left ICA spontaneous dissection with pseudoaneurysm. A follow-up angiogram 5 months later confirmed pseudoaneurysm thrombosis and patency of the left ICA. The patient recovered completely from the deficits.

  15. Treatment of Cervical Internal Carotid Artery Spontaneous Dissection with Pseudoaneurysm and Unilateral Lower Cranial Nerves Palsy by Two Silk Flow Diverters

    International Nuclear Information System (INIS)

    Zeleňák, Kamil; Zeleňáková, Jana; DeRiggo, Július; Kurča, Egon; Kantorová, Ema; Poláček, Hubert

    2013-01-01

    Internal carotid artery (ICA) lesions in the parapharyngeal space (a dissection and a pseudoaneurysm) may present as isolated lower cranial nerves (IX, X, XI, and XII) palsy (Collet–Sicard syndrome). Some arteriopathies such as fibromuscular dysplasia and tortuosity make a vessel predisposed to dissection. Extreme vessel tortuosity makes the treatment by a stent graft impossible. Two Silk stents were used in a 46 year-old man with left lower cranial nerves (IX–XII) palsy for the treatment of left ICA spontaneous dissection with pseudoaneurysm. A follow-up angiogram 5 months later confirmed pseudoaneurysm thrombosis and patency of the left ICA. The patient recovered completely from the deficits

  16. Valve-sparing root replacement in children with aortic root aneurysm: mid-term results.

    Science.gov (United States)

    Lange, Rüdiger; Badiu, Catalin C; Vogt, Manfred; Voss, Bernhard; Hörer, Jürgen; Prodan, Zsolt; Schreiber, Christian; Mazzitelli, Domenico

    2013-05-01

    We aimed at evaluating the results of aortic valve-sparing root replacement (AVSRR) in children with aortic root aneurysm (ARA) due to genetic disorders in terms of mortality, reoperation and recurrent aortic valve regurgitation (AVR). Thirteen patients (mean age 9.7 ± 6.5 years, 10 months-18 years) underwent AVSRR for ARA between 2002 and 2011. Six of the 13 patients had Marfan syndrome, 3 Loeys-Dietz syndrome (LDS), 2 bicuspid aortic valve syndrome and 2 an unspecified connective tissue disorder. AVR was graded as none/trace, mild and severe in 5, 7 and 1 patient, respectively. The mean pre-operative root diameter was 45 ± 10 mm (mean Z-score 10.3 ± 2.0). Remodelling of the aortic root was performed in 4 patients, reimplantation of the aortic valve in 9 and a concomitant cusp repair in 4. The diameter of the prostheses used for root replacement varied from 22 to 30 mm (mean Z-score = 2.3 ± 3). The follow-up was 100% complete with a mean follow-up time of 3.7 years. There was no operative mortality. One patient with LDS died 2.5 years after the operation due to spontaneous rupture of the descending aorta. Root re-replacement with mechanical conduit was necessary in 1 patient for severe recurrent AVR 8 days after remodelling of the aortic root. At final follow-up, AVR was graded as none/trace and mild in all patients. Eleven patients presented in New York Heart Association functional Class I and 1 in Class II. In paediatric patients with ARA, valve-sparing root replacement can be performed with low operative risk and excellent mid-term valve durability. Hence, prosthetic valve-related morbidity may be avoided. Due to the large diameters of the aortic root and the ascending aorta, the size of the implanted root prostheses will not limit later growth of the native aorta.

  17. Presentation of an uncommon form of aortic dissection and rupture in Marifoan syndrome; Presentacion de una forma infecuente de diseccion y rotura aortica en el sindrome de Marfan

    Energy Technology Data Exchange (ETDEWEB)

    Delgado, I; Ruiz, R; Villanueva, J M; Fernandez Cueto, J L [Servicio de Radiodiagnostico, Complejo Hospitalario, Ciudad Real (Spain)

    1995-11-01

    In Marfan syndrome, aneurysmatic enlargement of ascending aorta and dissection starting at the root are the most common cardiovascular complications. We present an infrequent case of a 15-year-old patient with a typical case of Marfan syndrome. CT disclosed an aorta and aortic arch of normal size with dissection originating distally with respect to the point where left subclavian artery arises. The disecction extended to descending aorta and to iliac and femoral arteries. Aortic rupture occurred in the arch, with massive hemothorax. The CT findings were confirmed at necropsy. 9 refs.

  18. Incidence and predictors of post-catheterization femoral artery pseudoaneurysms

    OpenAIRE

    Kassem, Hussein Heshmat; Elmahdy, Mahmoud Farouk; Ewis, Essam Baligh; Mahdy, Soilman Ghareeb

    2013-01-01

    Background: Femoral artery pseudoaneurysm (FAP) is a troublesome complication after transfemoral catheter procedures. The incidence and predictors of FAP as a separate entity have not been extensively studied. Aim: Detect prospectively the incidence and predictors of post catheterization FAP. Methods: From June 2009 till June 2011, we prospectively included all patients who underwent catheterization from the femoral approach. Duplex ultrasound was performed in cases with clinical suspic...

  19. Thoracic and abdominal aortic diameters in a general population: MRI-based reference values and association with age and cardiovascular risk factors

    Energy Technology Data Exchange (ETDEWEB)

    Mensel, Birger; Hesselbarth, Lydia; Wenzel, Michael; Kuehn, Jens-Peter; Hegenscheid, Katrin [University Medicine Greifswald, Institute of Diagnostic Radiology and Neuroradiology, Greifswald (Germany); Doerr, Marcus [University Medicine Greifswald, Department of Internal Medicine, Greifswald (Germany); DZHK (German Center for Cardiovascular Research), partner site Greifswald, Greifswald (Germany); Voelzke, Henry [University Medicine Greifswald, Institute for Community Medicine, Greifswald (Germany); DZHK (German Center for Cardiovascular Research), partner site Greifswald, Greifswald (Germany); Lieb, Wolfgang [Christian Albrechts University, Institute of Epidemiology, Kiel (Germany); Lorbeer, Roberto [Ludwig-Maximilians-University Hospital, Institute of Clinical Radiology, Munich (Germany)

    2016-04-15

    To generate reference values for thoracic and abdominal aortic diameters determined by magnetic resonance imaging (MRI) and analyse their association with cardiovascular risk factors in the general population. Data from participants (n = 1759) of the Study of Health in Pomerania were used for analysis in this study. MRI measurement of thoracic and abdominal aortic diameters was performed. Parameters for calculation of reference values according to age and sex analysis were provided. Multivariable linear regression models were used for determination of aortic diameter-related risk factors, including smoking, blood pressure (BP), high-density lipoprotein cholesterol (HDL-C). For the ascending aorta (β = -0.049, p < 0.001), the aortic arch (β = -0.061, p < 0.001) and the subphrenic aorta (β = -0.018, p = 0.004), the body surface area (BSA)-adjusted diameters were lower in men. Multivariable-adjusted models revealed significant increases in BSA-adjusted diameters with age for all six aortic segments (p < 0.001). Consistent results for all segments were observed for the positive associations of diastolic BP (β = 0.001; 0.004) and HDL (β = 0.035; 0.087) with BSA-adjusted aortic diameters and for an inverse association of systolic BP (β = -0.001). Some BSA-adjusted median aortic diameters are smaller in men than in women. All diameters increase with age, diastolic blood pressure and HDL-C and decrease as systolic BP increases. (orig.)

  20. An Infectious Pseudoaneurysm Caused by Ventricular Septal Defect Occluder in Patent Ductus Arteriosus Closure in a Two-Year-Old Child.

    Science.gov (United States)

    Li, Dingyang; Qiu, Qiu; Jin, Jing; Zhang, Changdong; Wang, Lijun; Zhang, Gangcheng

    2017-12-12

    We present a case of an infectious pseudoaneurysm after patent ductus arteriosus (PDA) closure with a ventricular septal defect (VSD) occluder in a two-year-old child. The aneurysm grew rapidly but was successfully removed in time and the patient survived. To our knowledge, this is the first report of an infectious pseudoaneurysm caused by VSD occluder in PDA closure.

  1. Elephant trunk in a small-calibre true lumen for chronic aortic dissection: cause of haemolytic anaemia?

    Science.gov (United States)

    Araki, Haruna; Kitamura, Tadashi; Horai, Tetsuya; Shibata, Ko; Miyaji, Kagami

    2014-12-01

    The elephant trunk technique for aortic dissection is useful for reducing false lumen pressure; however, a folded vascular prosthesis inside the aorta can cause haemolysis. The purpose of this study was to investigate whether an elephant trunk in a small-calibre lumen can cause haemolysis. Inpatient and outpatient records were retrospectively reviewed. Two cases of haemolytic anaemia after aortic surgery using the elephant trunk technique were identified from 2011 to 2013. A 64-year-old man, who underwent graft replacement of the ascending aorta for acute Stanford type A aortic dissection, presented with enlargement of the chronic dissection of the descending aorta and moderate aortic regurgitation. A two-stage surgery was scheduled. Total arch replacement with an elephant trunk in the true lumen and concomitant aortic valve replacement were performed. Postoperatively, he developed severe haemolytic anaemia because of the folded elephant trunk. The anaemia improved after the second surgery, including graft replacement of the descending aorta. Similarly, a 61-year-old man, who underwent total arch replacement for acute Stanford type A aortic dissection, presented with enlargement of the chronic dissection of the descending aorta. Graft replacement of the descending aorta with an elephant trunk inserted into the true lumen was performed. The patient postoperatively developed haemolytic anaemia because of the folded elephant trunk, which improved after additional stent grafting into the elephant trunk. A folded elephant trunk in a small-calibre lumen can cause haemolysis. Therefore, inserting an elephant trunk in a small-calibre true lumen during surgery for chronic aortic dissection should be avoided. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  2. Endovascular Treatment of Pseudoaneurysm of the Common Hepatic Artery with Intra-aneurysmal Glue (N-Butyl 2-Cyanoacrylate) Embolization

    International Nuclear Information System (INIS)

    Garg, Ashwin; Banait, Swati; Babhad, Sudeep; Kanchankar, Niraj; Nimade, Pradeep; Panchal, Chintan

    2007-01-01

    A 40-year-old man, a chronic alcoholic, presented with acute epigastric pain. Selective celiac arteriography showed a pseudoaneurysm arising from the common hepatic artery. We hereby describe a technical innovation where complete pseudoaneurysm exclusion was seen after intra-aneurysmal N-butyl 2-cyanoacrylate (glue) injection with preservation of antegrade hepatic arterial flow and conclude that intra-aneurysmal liquid injection may have potential as a therapeutic option to reconstruct a defective vessel wall and thereby maintain the antegrade flow

  3. Endovascular repair of an innominate artery pseudoaneurysm using the Valiant Mona LSA branched graft device

    Directory of Open Access Journals (Sweden)

    Josh A. Sibille, MD

    2017-03-01

    Full Text Available A 60-year-old woman involved in a motor vehicle collision presented with a traumatic pseudoaneurysm of the innominate artery origin in addition to multiple concomitant injuries. She was classified as a high-risk candidate for open repair. An experimental thoracic branched graft device was used for coverage of the injury with the addition of a right carotid-to-left carotid-to-left subclavian artery bypass. Follow-up imaging showed resolution of the pseudoaneurysm and patency of her bypass grafts. This is the first described use of the Mona LSA Branch Thoracic Stent Graft System (Medtronic, Minneapolis, Minn in the innominate artery.

  4. Management of a Complicated Ruptured Infected Pseudoaneurysm of the Femoral Artery in a Drug Addict

    Directory of Open Access Journals (Sweden)

    Emmanouil Psathas

    2012-01-01

    Full Text Available Infected pseudoaneurysm of the femoral artery represents a devastating complication of intravenous drug abuse, especially in the event of rupture. Operative strategy depends upon the extent of arterial injury and the coexistence of infection or sepsis. Options range from simple common femoral artery (CFA ligation to complex arterial reconstruction with autologous grafts (arterial, venous, or homografts. We report herein the management of a 29-year-old male patient who was urgently admitted with a ruptured pseudoaneurysm of the right CFA, extending well above the inguinal ligament. Multidisciplinary approach with multiple arterial reconstructions and subsequent coverage of the tissue defect with a rectus abdominis musculocutaneous flap transposition was performed.

  5. 4D Flow Analysis of BAV-Related Fluid-Dynamic Alterations: Evidences of Wall Shear Stress Alterations in Absence of Clinically-Relevant Aortic Anatomical Remodeling

    Directory of Open Access Journals (Sweden)

    Filippo Piatti

    2017-06-01

    Full Text Available Bicuspid aortic valve (BAV is the most common congenital cardiac disease and is a foremost risk factor for aortopathies. Despite the genetic basis of BAV and of the associated aortopathies, BAV-related alterations in aortic fluid-dynamics, and particularly in wall shear stresses (WSSs, likely play a role in the progression of aortopathy, and may contribute to its pathogenesis. To test whether WSS may trigger aortopathy, in this study we used 4D Flow sequences of phase-contrast cardiac magnetic resonance imaging (CMR to quantitatively compare the in vivo fluid dynamics in the thoracic aorta of two groups of subjects: (i five prospectively enrolled young patients with normo-functional BAV and with no aortic dilation and (ii ten age-matched healthy volunteers. Through the semi-automated processing of 4D Flow data, the aortic bulk flow at peak systole was quantified, and WSSs acting on the endothelium of the ascending aorta were characterized throughout the systolic phase in terms of magnitude and time-dependency through a method recently developed by our group. Variables computed for each BAV patient were compared vs. the corresponding distribution of values obtained for healthy controls. In BAV patients, ascending aorta diameter was measured on cine-CMR images at baseline and at 3-year follow-up. As compared to controls, normo-functional BAV patients were characterized by minor bulk flow disturbances at peak systole. However, they were characterized by evident alterations of WSS distribution and peak values in the ascending aorta. In particular, in four BAV patients, who were characterized by right-left leaflet fusion, WSS peak values exceeded by 27–46% the 90th percentile of the distribution obtained for healthy volunteers. Only in the BAV patient with right-non-coronary leaflet fusion the same threshold was exceeded by 132%. Also, evident alterations in the time-dependency of WSS magnitude and direction were observed. Despite, these fluid

  6. Embolization Coils Migrating and Being Passed per Rectum After Embolization of a Splenic Artery Pseudoaneurysm, 'The Migrating Coil': A Case Report

    International Nuclear Information System (INIS)

    Shah, Numan A.; Akingboye, Akinfemi; Haldipur, Nandon; Mackinlay, James Y.; Jacob, George

    2007-01-01

    Acute or chronic blood loss from pseudoaneurysms of the splanchnic artery in chronic pancreatitis poses diagnostic and management challenges. Arteriographic examination offers both diagnostic and therapeutic options, with success rates of 76%-100% for both modalities. In cases of failure of embolization, repeat embolization is also an option. Surgical intervention is advocated for rebleeding and failure of embolization. Evidence-based guidelines regarding the optimal treatment modality for this condition are lacking. There has been a reported case of dislodgement of coil into the stomach through a gastropseudocystic fistula. We report the case of a migrating steel-wire coil through the gastrointestinal tract and splenic artery pseudoaneurysm. We highlight the potential complications of pseudoaneurysm and other available therapeutic management options

  7. Aortic valve replacement with the Biocor PSB stentless xenograft.

    Science.gov (United States)

    Bertolini, P; Luciani, G B; Vecchi, B; Pugliese, P; Mazzucco, A

    1998-08-01

    The midterm clinical results after aortic valve replacement with the Biocor PSB stentless xenograft on all patients operated between October 1992 and October 1996 were reviewed. One hundred six patients, aged 70+/-6 years, had aortic valve replacement for aortic stenosis (67%), regurgitation (11%), or both (22%). Associated procedures were done in 49 patients (46%), including coronary artery bypass in 30 patients, mitral valve repair/replacement in 16, and ascending aorta replacement in 5 patients. Aortic cross-clamp and cardiopulmonary bypass times were 96+/-24 and 129+/-31 minutes, respectively. There were 3 (3%) early deaths due to low output (2 patients) and cerebrovascular accident (1 patient). Follow-up of survivors ranged from 6 to 66 months (mean, 39+/-14 months). Survival was 94%+/-2% and 90%+/-3% at 1 and 5 years. There were 5 late deaths due to cardiac cause (2), cancer (2), and pulmonary embolism (1 patient). No patient had structural valve deterioration, whereas 100% and 95%+/-3% were free from valve-related events at 1 and 5 years. There were two reoperations due to narrowing of the left coronary ostium and endocarditis, with an actuarial freedom from reoperation of 99%+/-1% and 98+/-1% at 1 and 5 years, respectively. Functional results demonstrated a mean peak transprosthetic gradient of 16+/-12 mm Hg, with only 1 patient (1%) with a 55 mm Hg gradient. No cases of valve regurgitation greater than mild were recorded at follow-up. Assessment of New York Heart Association functional class demonstrated a significant improvement (2.9+/-0.6 versus 1.4+/-0.7; p=0.01). All patients were free from anticoagulation. Aortic valve replacement using the Biocor PSB stentless xenograft offers excellent midterm survival, negligible valve deterioration, and a very low rate of valve-related events, which are comparable to estimates reported with other models of stentless xenografts and currently available stented xenografts. Hemodynamic performance is favorable and

  8. Primary Infrarenal Aortic Stenting With or Without Iliac Stenting for Isolated and Aortoiliac Stenoses: Single-Centre Experience With Long-Term Follow-Up

    International Nuclear Information System (INIS)

    Tapping, C. R.; Ahmed, M.; Scott, P. M.; Lakshminarayan, R.; Robinson, G. J.; Ettles, D. F.; Shrivastava, V.

    2013-01-01

    The purpose of this study was to evaluate the technical success, complications, long-term clinical outcome, and patency after primary infrarenal aortic stenting for aortic and aortoiliac stenosis. Between January 1999 and January 2006, 22 consecutive patients underwent endovascular treatment because of infrarenal aortic stenosis with and without common iliac stenosis (10 men; mean age 64 ± 14 years). Eleven (11 of 22) patients had an isolated aortic stenosis, whereas 11 of 22 had aortic stenosis that extended into the common iliac arteries (CIAs). Thirteen patients were Rutherford classification type 3, and 9 patients were type 4. Statistical analysis included paired Student t test and Kaplan–Meier life table analysis; p < 0.05 was considered significant. Technical and initial clinical success was achieved in all patients. There were three (14 %) procedure-related complications, which included two access-point pseudoaneurysms and one non–flow-limiting left external iliac dissection. Patients were followed-up for a mean period of 88 months (range 60–132). Mean preprocedure ankle brachial pressure indexes (ABPI) were 0.60 ± −0.15 (right) and 0.61 ± −0.16 (left). After the procedure they were 0.86 ± −0.07 (right) and 0.90 ± −0.09 (left). The increase in ABPI was significant (p < 0.05), and this continued throughout follow-up. Four (18 %) patients had recurrence of symptoms during follow-up. These occurred at 36, 48, 48, and 50 months after the original procedure. All four patients were successfully treated with repeat angioplasty procedures. There was a significant difference in primary patency between isolated aortic stenosis (100 %) and aortoiliac stenosis (60 %) (p = 0.031). Cumulative follow-up was 1920 months yielding a reintervention rate of 0.025/events/year. Primary stenting of infrarenal stenosis is safe and successful with a low reintervention rate. It should be considered as first-line treatment for patients with infrarenal aortic

  9. Acute Aortic Arch Perforation During Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis and a Gothic Aortic Arch.

    Science.gov (United States)

    Millan-Iturbe, Oscar; Sawaya, Fadi J; Bieliauskas, Gintautas; Chow, Danny H F; De Backer, Ole; Søndergaard, Lars

    2017-09-01

    Transcatheter aortic valve replacement (TAVR) has evolved from a novel technology to an established therapy for high/intermediate-risk patients with severe symptomatic aortic stenosis (AS). Although TAVR is used to treat bicuspid severe AS, the large randomized trials typically excluded bicuspid AS because of its unique anatomic features. This case report describes an acute aortic perforation during delivery of a transcatheter heart valve to treat a severe bicuspid AS with a "gothic aortic arch"; more careful evaluation of the preprocedural multislice computed tomographic scan would have unveiled a sharply angulated aortic arch. This life-threatening complication was successfully treated by thoracic endovascular aortic repair. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  10. Retrograde type A dissection following hybrid supra-aortic endovascular surgery in high-risk patients unfit for conventional open repair.

    Science.gov (United States)

    Yip, Hon C; Chan, Yiu C; Qing, Kai X; Cheng, Stephen W

    2018-04-01

    Hybrid procedures with combined open extra-anatomical supra-aortic bypasses and endovascular surgery are less invasive for patients with complex aortic arch pathology. The aim of this paper is to report patients who developed retrograde type A aortic dissection following initially successful hybrid endovascular treatment. Retrospective review of prospectively collected computerized departmental database. All patients with supra-aortic hybrid endovascular surgery and post-procedure retrograde type A dissection were identified. Patient demographics, comorbid conditions, perioperative parameters, procedural details and post-operative complications were collected. From May 2005 to July 2014, 163 patients underwent thoracic aortic endovascular procedures at our institution. From the 46 patients who had supra-aortic hybrid endovascular repair, six patients (6/46, 13% of all supra-aortic hybrid cases, 3 males) developed retrograde type A aortic dissection. All were elective cases, with 3 chronic dissecting aneurysms and 3 atherosclerotic aneurysms. All had one-stage hybrid procedures: 2 patients had carotid-carotid bypass grafts, one had carotid-carotid-left subclavian bypass graft, and 3 had bypass grafts from ascending aorta to innominate artery and left carotid artery. Five patients had Cook Zenith thoracic stent-grafts (Cook Medical, Bloomington, IN, USA), and one had Medtronic Valiant stent-grafts (Medtronic Vascular Inc, Santa Rosa, CA, USA). The retrograde type A dissection occurred with sudden symptoms at day 5, 6, 10, 20, 105 and 128, respectively. There were 3 immediate fatalities and 2 patients treated conservatively deemed unfit for reintervention (one died of pneumonia at 9 months, and one remained alive at 7 months post-complication). One patient underwent successful emergency open surgery and survived. Supra-aortic hybrid procedures in treating aortic arch pathology may be at risk of developing retrograde type A dissection. This post-operative complication

  11. Endovascular Treatment of Persistent Epistaxis due to Pseudoaneurysm Formation of the Ophthalmic Artery Secondary to Nasogastric Tube

    Energy Technology Data Exchange (ETDEWEB)

    Selcuk, Hakan, E-mail: hakanselcuk73@yahoo.com; Soylu, Nur; Albayram, Sait; Selcuk, Dogan; Ozer, Harun; Kocer, Naci; Islak, Civan [Cerrahpasa Medical School, Istanbul University, Department of Radiology, Division of Neuroradiology (Turkey)

    2005-04-15

    We present the case of a 60-year-old man with persistent epistaxis for 20 days that had started 2 weeks after removal of a nasogastric tube placed for an abdominal operation. There was no pathologic finding at selective facial and internal maxillary artery injections. An injury to the ethmoidal branches of the ophthalmic arteries or other arterial origins of bleeding was suspected. The internal carotid artery angiography revealed a pseudoaneurysm of an anterior ethmoidal branch of the left ophthalmic artery. The pseudoaneurysm was occluded with NBCA-histoacryl (25%) injection.

  12. Endovascular Treatment of Persistent Epistaxis due to Pseudoaneurysm Formation of the Ophthalmic Artery Secondary to Nasogastric Tube

    International Nuclear Information System (INIS)

    Selcuk, Hakan; Soylu, Nur; Albayram, Sait; Selcuk, Dogan; Ozer, Harun; Kocer, Naci; Islak, Civan

    2005-01-01

    We present the case of a 60-year-old man with persistent epistaxis for 20 days that had started 2 weeks after removal of a nasogastric tube placed for an abdominal operation. There was no pathologic finding at selective facial and internal maxillary artery injections. An injury to the ethmoidal branches of the ophthalmic arteries or other arterial origins of bleeding was suspected. The internal carotid artery angiography revealed a pseudoaneurysm of an anterior ethmoidal branch of the left ophthalmic artery. The pseudoaneurysm was occluded with NBCA-histoacryl (25%) injection

  13. Group B streptococcus exploits vaginal epithelial exfoliation for ascending infection.

    Science.gov (United States)

    Vornhagen, Jay; Armistead, Blair; Santana-Ufret, Verónica; Gendrin, Claire; Merillat, Sean; Coleman, Michelle; Quach, Phoenicia; Boldenow, Erica; Alishetti, Varchita; Leonhard-Melief, Christina; Ngo, Lisa Y; Whidbey, Christopher; Doran, Kelly S; Curtis, Chad; Waldorf, Kristina M Adams; Nance, Elizabeth; Rajagopal, Lakshmi

    2018-04-09

    Thirteen percent of pregnancies result in preterm birth or stillbirth, accounting for fifteen million preterm births and three and a half million deaths annually. A significant cause of these adverse pregnancy outcomes is in utero infection by vaginal microorganisms. To establish an in utero infection, vaginal microbes enter the uterus by ascending infection; however, the mechanisms by which this occurs are unknown. Using both in vitro and murine models of vaginal colonization and ascending infection, we demonstrate how a vaginal microbe, group B streptococcus (GBS), which is frequently associated with adverse pregnancy outcomes, uses vaginal exfoliation for ascending infection. GBS induces vaginal epithelial exfoliation by activation of integrin and β-catenin signaling. However, exfoliation did not diminish GBS vaginal colonization as reported for other vaginal microbes. Rather, vaginal exfoliation increased bacterial dissemination and ascending GBS infection, and abrogation of exfoliation reduced ascending infection and improved pregnancy outcomes. Thus, for some vaginal bacteria, exfoliation promotes ascending infection rather than preventing colonization. Our study provides insight into mechanisms of ascending infection by vaginal microbes.

  14. Embolization of iatrogenic uterine pseudoaneurysm

    Directory of Open Access Journals (Sweden)

    Luca Boi

    2017-05-01

    Full Text Available Uterine artery pseudoaneurysms (UAPs are rare vascular lesions that may be life threatening if not diagnosed and properly treated. The clinical presentation of UAPs includes a spectrum of symptoms that are often associated with other and more frequent gynecologic/obstetric pathologies, both with and without vaginal bleeding, and may span from postpartum hemorrhage to the absence of symptoms. We report cases of two patients with UAP, both of whom were diagnosed with ultrasonography and contrast-enhanced computed tomography and successfully treated with transcatheter embolization. The first patient presented delayed hypovolemic shock following surgery for endometriosis, whereas the second patient suffered from postpartum hemorrhage after cesarean section. Diagnosis of UAPs relies on noninvasive imaging; transcatheter arterial embolization is an effective treatment to control bleeding in both hemodynamically stable and unstable patients.

  15. Image quality and diagnostic accuracy of unenhanced SSFP MR angiography compared with conventional contrast-enhanced MR angiography for the assessment of thoracic aortic diseases

    International Nuclear Information System (INIS)

    Krishnam, Mayil S.; Tomasian, Anderanik; Malik, Sachin; Ruehm, Stefan G.; Desphande, Vibhas; Laub, Gerhard

    2010-01-01

    The purpose of this study was to determine the image quality and diagnostic accuracy of three-dimensional (3D) unenhanced steady state free precession (SSFP) magnetic resonance angiography (MRA) for the evaluation of thoracic aortic diseases. Fifty consecutive patients with known or suspected thoracic aortic disease underwent free-breathing ECG-gated unenhanced SSFP MRA with non-selective radiofrequency excitation and contrast-enhanced (CE) MRA of the thorax at 1.5 T. Two readers independently evaluated the two datasets for image quality in the aortic root, ascending aorta, aortic arch, descending aorta, and origins of supra-aortic arteries, and for abnormal findings. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were determined for both datasets. Sensitivity, specificity, and diagnostic accuracy of unenhanced SSFP MRA for the diagnosis of aortic abnormalities were determined. Abnormal aortic findings, including aneurysm (n = 47), coarctation (n = 14), dissection (n = 12), aortic graft (n = 6), intramural hematoma (n = 11), mural thrombus in the aortic arch (n = 1), and penetrating aortic ulcer (n = 9), were confidently detected on both datasets. Sensitivity, specificity, and diagnostic accuracy of SSFP MRA for the detection of aortic disease were 100% with CE-MRA serving as a reference standard. Image quality of the aortic root was significantly higher on SSFP MRA (P 0.05). SNR and CNR values were higher for all segments on SSFP MRA (P < 0.01). Our results suggest that free-breathing navigator-gated 3D SSFP MRA with non-selective radiofrequency excitation is a promising technique that provides high image quality and diagnostic accuracy for the assessment of thoracic aortic disease without the need for intravenous contrast material. (orig.)

  16. Intimal aortic sarcoma mimicking ruptured thoracoabdominal type IV aneurysm. a rare case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Dedeilias Panagiotis

    2011-12-01

    Full Text Available Abstract Primary intimal aortic sarcoma represents a very rare and highly lethal medical entity. Diagnosis is made either by embolic events caused by the tumor or by surrounding tissue symptoms such as pain. Herein we report an extremely rare case of a 51-year-old man previously operated for ascending aortic aneurysm, who presented with clinical and radiological findings suggestive of a ruptured thoracoabdominal type IV aneurysm. The patient underwent radical resection of the aorta and surrounding tissue with placement of a composite 4-branched graft. The diagnosis was made by frozen section and regular histopathologic examination of the specimen and the patient received adjuvant chemotherapy. Nine months after surgery the patient is still alive and has no signs of recurrence. We review the literature and discuss the option of postoperative chemotherapy.

  17. JAG Tearing Technique with Radiofrequency Guide Wire for Aortic Fenestration in Thoracic Endovascular Aneurysm Repair

    International Nuclear Information System (INIS)

    Ricci, Carmelo; Ceccherini, Claudio; Leonini, Sara; Cini, Marco; Vigni, Francesco; Neri, Eugenio; Tucci, Enrico; Benvenuti, Antonio; Tommasino, Giulio; Sassi, Carlo

    2012-01-01

    An innovative approach, the JAG tearing technique, was performed during thoracic endovascular aneurysm repair in a patient with previous surgical replacement of the ascending aorta with a residual uncomplicated type B aortic dissection who developed an aneurysm of the descending thoracic aorta with its lumen divided in two parts by an intimal flap. The proximal landing zone was suitable to place a thoracic stent graft. The distal landing zone was created by cutting the intimal flap in the distal third of the descending thoracic aorta with a radiofrequency guide wire and intravascular ultrasound catheter.

  18. Mucormycosis resulting in a pseudoaneurysm in the spleen

    Energy Technology Data Exchange (ETDEWEB)

    Nevitt, P.C.; Das Narla, L. [Medical College of Virginia, Virginia Commonwealth Univ., Richmond (United States); Hingsbergen, E.A. [Children' s Radiologic Institute, Children' s Hospital, Columbus, OH (United States)

    2001-02-01

    Mucormycosis is an uncommon and frequently fatal fungal infection. It characteristically affects patients with diabetes mellitus or patients with severe immunosuppression. The hallmark of mucormycosis infection is tissue infarction and vascular invasion. We present clinical data and imaging studies of a 16 year-old child with acute lymphoblastic leukemia complicated by disseminated mucormycosis resulting in a pseudoaneurysm of the spleen. This was successfully managed by a combination of systemic antifungal therapy (Amphotericin B) and surgery (splenectomy). This entity has not been described in the literature. (orig.)

  19. Mucormycosis resulting in a pseudoaneurysm in the spleen

    International Nuclear Information System (INIS)

    Nevitt, P.C.; Das Narla, L.; Hingsbergen, E.A.

    2001-01-01

    Mucormycosis is an uncommon and frequently fatal fungal infection. It characteristically affects patients with diabetes mellitus or patients with severe immunosuppression. The hallmark of mucormycosis infection is tissue infarction and vascular invasion. We present clinical data and imaging studies of a 16 year-old child with acute lymphoblastic leukemia complicated by disseminated mucormycosis resulting in a pseudoaneurysm of the spleen. This was successfully managed by a combination of systemic antifungal therapy (Amphotericin B) and surgery (splenectomy). This entity has not been described in the literature. (orig.)

  20. Characteristic Morphologies of the Bicuspid Aortic Valve in Patients with Genetic Syndromes.

    Science.gov (United States)

    Niaz, Talha; Poterucha, Joseph T; Olson, Timothy M; Johnson, Jonathan N; Craviari, Cecilia; Nienaber, Thomas; Palfreeman, Jared; Cetta, Frank; Hagler, Donald J

    2018-02-01

    In patients with bicuspid aortic valve (BAV), complications including progressive aortic stenosis and aortic dilatation develop over time. The morphology of cusp fusion is one of the determinants of the type and severity of these complications. We present the association of morphology of cusp fusion in BAV patients with distinctive genetic syndromes. The Mayo Clinic echocardiography database was retrospectively reviewed to identify patients (age ≤ 22 years) diagnosed with BAV from 1990 to 2016. Cusp fusion morphology was determined from the echocardiographic studies, while coexisting cardiac defects and genetic syndromes were determined from chart review. A total of 1,037 patients with BAV were identified: 550 (53%) had an isolated BAV, 299 (29%) had BAV and a coexisting congenital heart defect, and 188 (18%) had BAV and a coexisting genetic syndrome or disorder. There were no differences in distribution of morphology across the three groups. However, right-noncoronary (RN) cusp fusion was the predominant morphology associated with Down syndrome (P = .002) and right-left (RL) cusp fusion was the predominant morphology associated with Turner syndrome (P = .02), DiGeorge syndrome (P = .02), and Shone syndrome (P = .0007), when compared with valve morphology in patients with isolated BAV. Isolated BAV patients with RN cusp fusion had larger ascending aorta diameter (P = .001) and higher number of patients with ≥ moderate aortic regurgitation (P = .02), while those with RL cusp fusion had larger sinus of Valsalva diameter (P = .0006). Morphological subtypes of BAV are associated with different genetic syndromes, suggesting distinct perturbations of developmental pathways in aortic valve malformation. Copyright © 2017 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  1. Image quality and diagnostic accuracy of unenhanced SSFP MR angiography compared with conventional contrast-enhanced MR angiography for the assessment of thoracic aortic diseases

    Energy Technology Data Exchange (ETDEWEB)

    Krishnam, Mayil S. [University of California, Cardiovascular and Thoracic Imaging, UCI Medical Center, Irvine, CA (United States); Tomasian, Anderanik; Malik, Sachin; Ruehm, Stefan G. [University of California at Los Angeles, Department of Radiological Sciences, Ronald Reagan Medical Center, Los Angeles, CA (United States); Desphande, Vibhas; Laub, Gerhard [Siemens Medical Solutions, Los Angeles, CA (United States)

    2010-06-15

    The purpose of this study was to determine the image quality and diagnostic accuracy of three-dimensional (3D) unenhanced steady state free precession (SSFP) magnetic resonance angiography (MRA) for the evaluation of thoracic aortic diseases. Fifty consecutive patients with known or suspected thoracic aortic disease underwent free-breathing ECG-gated unenhanced SSFP MRA with non-selective radiofrequency excitation and contrast-enhanced (CE) MRA of the thorax at 1.5 T. Two readers independently evaluated the two datasets for image quality in the aortic root, ascending aorta, aortic arch, descending aorta, and origins of supra-aortic arteries, and for abnormal findings. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were determined for both datasets. Sensitivity, specificity, and diagnostic accuracy of unenhanced SSFP MRA for the diagnosis of aortic abnormalities were determined. Abnormal aortic findings, including aneurysm (n = 47), coarctation (n = 14), dissection (n = 12), aortic graft (n = 6), intramural hematoma (n = 11), mural thrombus in the aortic arch (n = 1), and penetrating aortic ulcer (n = 9), were confidently detected on both datasets. Sensitivity, specificity, and diagnostic accuracy of SSFP MRA for the detection of aortic disease were 100% with CE-MRA serving as a reference standard. Image quality of the aortic root was significantly higher on SSFP MRA (P < 0.001) with no significant difference for other aortic segments (P > 0.05). SNR and CNR values were higher for all segments on SSFP MRA (P < 0.01). Our results suggest that free-breathing navigator-gated 3D SSFP MRA with non-selective radiofrequency excitation is a promising technique that provides high image quality and diagnostic accuracy for the assessment of thoracic aortic disease without the need for intravenous contrast material. (orig.)

  2. Evaluation of Marfan patients status post valve-sparing aortic root replacement with 4D flow.

    Science.gov (United States)

    Hope, Thomas A; Kvitting, John-Peder Escobar; Hope, Michael D; Miller, D Craig; Markl, Michael; Herfkens, Robert J

    2013-11-01

    Over the past two decades elective valve-sparing aortic root replacement (V-SARR) has become more common in the treatment of patients with aortic root and ascending aortic aneurysms. Currently there are little data available to predict complications in the post-operative population. The study goal was to determine if altered flow patterns in the thoracic aorta, as measured by MRI, are associated with complications after V-SARR. Time-resolved three-dimensional phase-contrast MRI (4D flow) was used to image 12 patients with Marfan syndrome after V-SARR. The patients were followed up for an average of 5.8 years after imaging and 8.2 years after surgery. Additionally 5 volunteers were imaged for comparison. Flow profiles were visualized during peak systole using streamlines. Wall shear stress estimates and normalized flow displacement were evaluated at multiple planes in the thoracic aorta. During the follow-up period, a single patient developed a Stanford Type B aortic dissection. At initial imaging, prior to the development of the dissection, the patient had altered flow patterns, wall shear stress estimates, and increased normalized flow displacement in the thoracic aorta in comparison to the remaining V-SARR patients and volunteers. This is the first follow-up study of patients after 4D flow imaging. An aortic dissection developed in one patient with altered flow patterns and hemodynamic stresses in the thoracic aorta. These results suggest that flow and altered hemodynamics may play a role in the development of post-operative intramural hematomas and dissections. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Effect of tocotrienol on aortic atherosclerosis in diabetic mice

    International Nuclear Information System (INIS)

    Kiani, M.R.B.; Butt, S.A.; Ahmed, T.

    2015-01-01

    Effect of tocotrienol on aortic atherosclerosis in diabetic mice To study the histomorphological effect of tocotrienol on aortic atherosclerosis in diabetic mice having high fat diet. Study Design: Lab based randomized controlled trial. Place and Duration of Study: Army Medical College, Rawalpindi and National Institute of Health, Islamabad from November 2009 to June 2010. Material and Methods: Forty five female BALB/c mice were randomly divided into three groups. The diabetic mice model was established by intraperitoneal injection of streptozotocin (STZ) 40 mg/kg body weight. Group A was given normal laboratory diet, group B high fat diet and group C was given tocotrienol along with high fat diet for 32 weeks. At the end of experiment the mice were sacrificed. The hearts of animals were dissected out and ascending aortae were taken out. The specimen was fixed in 10% formol calcium and processed for paraffin embedding. Five micrometer thick sections were made for haematoxylin and eosin, and Verhoeff's staining. After staining, histomorphologic changes in slides were noted. Results: In contrast to group A, atheroscelrosis developed in groups B and C. Statistically significant atherosclerotic changes were found in the aortae of diabetic mice in group B when compared to group A. On comparison of group A to C, atherosclerotic changes were statistically insignificant. However when group B was compared with group C, the aortic atherosclerotic changes decreased significantly in group C. Conclusion: In diabetics with high fat diet intake, there is an increase in development of atherosclerosis in aorta which can be reduced by tocotrienol. (author)

  4. Scan-rescan reproducibility of segmental aortic wall shear stress as assessed by phase-specific segmentation with 4D flow MRI in healthy volunteers.

    Science.gov (United States)

    van der Palen, Roel L F; Roest, Arno A W; van den Boogaard, Pieter J; de Roos, Albert; Blom, Nico A; Westenberg, Jos J M

    2018-05-26

    The aim was to investigate scan-rescan reproducibility and observer variability of segmental aortic 3D systolic wall shear stress (WSS) by phase-specific segmentation with 4D flow MRI in healthy volunteers. Ten healthy volunteers (age 26.5 ± 2.6 years) underwent aortic 4D flow MRI twice. Maximum 3D systolic WSS (WSSmax) and mean 3D systolic WSS (WSSmean) for five thoracic aortic segments over five systolic cardiac phases by phase-specific segmentations were calculated. Scan-rescan analysis and observer reproducibility analysis were performed. Scan-rescan data showed overall good reproducibility for WSSmean (coefficient of variation, COV 10-15%) with moderate-to-strong intraclass correlation coefficient (ICC 0.63-0.89). The variability in WSSmax was high (COV 16-31%) with moderate-to-good ICC (0.55-0.79) for different aortic segments. Intra- and interobserver reproducibility was good-to-excellent for regional aortic WSSmax (ICC ≥ 0.78; COV ≤ 17%) and strong-to-excellent for WSSmean (ICC ≥ 0.86; COV ≤ 11%). In general, ascending aortic segments showed more WSSmax/WSSmean variability compared to aortic arch or descending aortic segments for scan-rescan, intraobserver and interobserver comparison. Scan-rescan reproducibility was good for WSSmean and moderate for WSSmax for all thoracic aortic segments over multiple systolic phases in healthy volunteers. Intra/interobserver reproducibility for segmental WSS assessment was good-to-excellent. Variability of WSSmax is higher and should be taken into account in case of individual follow-up or in comparative rest-stress studies to avoid misinterpretation.

  5. Aortic coarctation diagnosed by renal Doppler flow patterns in a hypertensive young patient: a case report

    International Nuclear Information System (INIS)

    Sari, S.; Kara, K.; Verim, S.

    2012-01-01

    Full text: Introduction: Aortic coarctation is a congenital malformation, which can cause systemic hypertension and subsequent complications, and causes of secondary hypertension, affecting in differential pressures in the upper and lower extremities. Because hypertension is caused by aortic coarctation, tends to be resistant to medical therapy, early recognition and surgical rectification are important. Objectives and tasks: In this article, we aimed to point out that renal Doppler sonography is a beneficial and frequently used to evaluate secondary hypertension, if there are bilateral tardus-parvus wave patterns are detected. Thus, bilateral renal artery stenosis, aortic stenosis, and coarctation should be considered in this condition. Materials and methods: A 23-year-old male who has six-month history of hypertension. He was referred by a cardiologist for investigation of his secondary hypertension. There was an ascending aortic dilatation, left ventricular hypertrophy in his echocardiography. Results: The patient's blood pressure was measured as 160/90 mm Hg in his both arms. Renal Doppler sonography was performed to identify the potential cause of secondary hypertension, specifically renal artery stenosis, after tardus-parvus pulse waves were noted in both renal intralobar-arteries. Aortic coarctation is suspected and then a chest computed tomography (CT) was performed to evaluate supra-diaphragmatic vessel abnormalities. The CT exposed a stenotic lesion in the isthmus of the aorta. The patient was transferred to cardiovascular surgery department for treatment. Conclusion: Careful physical examination should be performed in all hypertensive patients. If bilateral tardus-parvus wave pattern are seen in patients who has been referred for Doppler evaluation on suspicion of renovascular hypertension, aortic coarctation should be considered as differential diagnosis

  6. Induction of macrophage chemotaxis by aortic extracts from patients with Marfan syndrome is related to elastin binding protein.

    Directory of Open Access Journals (Sweden)

    Gao Guo

    Full Text Available Marfan syndrome is an autosomal dominantly inherited disorder of connective tissue with prominent skeletal, ocular, and cardiovascular manifestations. Aortic aneurysm and dissection are the major determinants of premature death in untreated patients. In previous work, we showed that extracts of aortic tissues from the mgR mouse model of Marfan syndrome showed increased chemotactic stimulatory activity related to the elastin-binding protein. Aortic samples were collected from 6 patients with Marfan syndrome and 8 with isolated aneurysms of the ascending aorta. Control samples were obtained from 11 organ donors without known vascular or connective tissue diseases. Soluble proteins extracted from the aortic samples of the two patient groups were compared against buffer controls and against the aortic samples from controls with respect to the ability to induce macrophage chemotaxis as measured using a modified Boyden chamber, as well as the reactivity to a monoclonal antibody BA4 against bioactive elastin peptides using ELISA. Samples from Marfan patients displayed a statistically significant increase in chemotactic inductive activity compared to control samples. Additionally, reactivity to BA4 was significantly increased. Similar statistically significant increases were identified for the samples from patients with idiopathic thoracic aortic aneurysm. There was a significant correlation between the chemotactic index and BA4 reactivity, and the increases in chemotactic activity of extracts from Marfan patients could be inhibited by pretreatment with lactose, VGVAPG peptides, or BA4, which indicates the involvement of EBP in mediating the effects. Our results demonstrate that aortic extracts of patients with Marfan syndrome can elicit macrophage chemotaxis, similar to our previous study on aortic extracts of the mgR mouse model of Marfan syndrome (Guo et al., Circulation 2006; 114:1855-62.

  7. Induction of Macrophage Chemotaxis by Aortic Extracts from Patients with Marfan Syndrome Is Related to Elastin Binding Protein

    Science.gov (United States)

    Guo, Gao; Gehle, Petra; Doelken, Sandra; Martin-Ventura, José Luis; von Kodolitsch, Yskert; Hetzer, Roland; Robinson, Peter N.

    2011-01-01

    Marfan syndrome is an autosomal dominantly inherited disorder of connective tissue with prominent skeletal, ocular, and cardiovascular manifestations. Aortic aneurysm and dissection are the major determinants of premature death in untreated patients. In previous work, we showed that extracts of aortic tissues from the mgR mouse model of Marfan syndrome showed increased chemotactic stimulatory activity related to the elastin-binding protein. Aortic samples were collected from 6 patients with Marfan syndrome and 8 with isolated aneurysms of the ascending aorta. Control samples were obtained from 11 organ donors without known vascular or connective tissue diseases. Soluble proteins extracted from the aortic samples of the two patient groups were compared against buffer controls and against the aortic samples from controls with respect to the ability to induce macrophage chemotaxis as measured using a modified Boyden chamber, as well as the reactivity to a monoclonal antibody BA4 against bioactive elastin peptides using ELISA. Samples from Marfan patients displayed a statistically significant increase in chemotactic inductive activity compared to control samples. Additionally, reactivity to BA4 was significantly increased. Similar statistically significant increases were identified for the samples from patients with idiopathic thoracic aortic aneurysm. There was a significant correlation between the chemotactic index and BA4 reactivity, and the increases in chemotactic activity of extracts from Marfan patients could be inhibited by pretreatment with lactose, VGVAPG peptides, or BA4, which indicates the involvement of EBP in mediating the effects. Our results demonstrate that aortic extracts of patients with Marfan syndrome can elicit macrophage chemotaxis, similar to our previous study on aortic extracts of the mgR mouse model of Marfan syndrome (Guo et al., Circulation 2006; 114:1855-62). PMID:21647416

  8. MR imaging of aortic coarctation

    International Nuclear Information System (INIS)

    Beslic, S.

    2004-01-01

    Purpose. The purpose of this paper is to analyse the contribution of MRI as diagnostic procedure in the preoperative diagnosis of aortic coarctation (CoA), in patients with clinical and echocardiographic suspicion for this disease. Patients and methods. During the period of three years, eight patients were examined, 5 (62.5%) male and 3 (37.5%) female patients with clinical echocardiographic suspicion of CoA. The ratio between male and female patients was 1.7 : 1. The youngest patient was 3 and the oldest 46 years (median age was 15 years). Without administration of contrast media and using body coil the examinations were performed with MR machine Magnetom 1.0 Tesla ( S iemens ) , with the slice thickness of 6 mm, Fast spin-echo (FSE) T1W sequences, Cine gradient echo (GRE) sequence with slab 7 mm and time of flight (TOF) sequence with MIP reconstructions were applied. During the examinations the patients underwent also ECG gating. Examinations were done in axial, coronal and oblique sagittal projections with measuring of the dimensions of cardiovascular structures. Results. CoA was found in 8 (100%) patients. In 7 (87.5%) cases, coarctation developed at isthmus and in one case, coarctation was detected at the horizontal part of aortic arch, between the truncus arteriosus of the left carotid communis artery. Aortal insufficiency was found in 7 (87.5%) patients; in four of them (50%), bicuspidia was confirmed (bicuspid aortic valve), 7 (87.5%) patients had slightly expressed hypertrophy of the left ventricle. Two (25%) patients had dilatation of the ascendant aorta, six (75%) wider outgoing vessels of the aortic arch, four (50%) had well developed arterial collaterals and 2 (25%) patients rib notching. In 2 (25%) patients as side finding thymus persistent was found. Average diameter of coarctation was 10 mm. In one patient, CoA was accompanied with stenosis of pulmonary artery, in one with ventricular septal defect, and one with tricuspid insufficiency. The results

  9. Elevated expression levels of lysyl oxidases protect against aortic aneurysm progression in Marfan syndrome.

    Science.gov (United States)

    Busnadiego, O; Gorbenko Del Blanco, D; González-Santamaría, J; Habashi, J P; Calderon, J F; Sandoval, P; Bedja, D; Guinea-Viniegra, J; Lopez-Cabrera, M; Rosell-Garcia, T; Snabel, J M; Hanemaaijer, R; Forteza, A; Dietz, H C; Egea, G; Rodriguez-Pascual, F

    2015-08-01

    Patients with Marfan syndrome (MFS) are at high risk of life-threatening aortic dissections. The condition is caused by mutations in the gene encoding fibrillin-1, an essential component in the formation of elastic fibers. While experimental findings in animal models of the disease have shown the involvement of transforming growth factor-β (TGF-β)- and angiotensin II-dependent pathways, alterations in the vascular extracellular matrix (ECM) may also play a role in the onset and progression of the aortic disease. Lysyl oxidases (LOX) are extracellular enzymes, which initiates the formation of covalent cross-linking of collagens and elastin, thereby contributing to the maturation of the ECM. Here we have explored the role of LOX in the formation of aortic aneurysms in MFS. We show that aortic tissue from MFS patients and MFS mouse model (Fbn1(C1039G/+)) displayed enhanced expression of the members of the LOX family, LOX and LOX-like 1 (LOXL1), and this is associated with the formation of mature collagen fibers. Administration of a LOX inhibitor for 8weeks blocked collagen accumulation and aggravated elastic fiber impairment, and these effects correlated with the induction of a strong and rapidly progressing aortic dilatation, and with premature death in the more severe MFS mouse model, Fbn1(mgR/mgR), without any significant effect on wild type animals. This detrimental effect occurred preferentially in the ascending portion of the aorta, with little or no involvement of the aortic root, and was associated to an overactivation of both canonical and non-canonical TGF-β signaling pathways. The blockade of angiotensin II type I receptor with losartan restored TGF-β signaling activation, normalized elastic fiber impairment and prevented the aortic dilatation induced by LOX inhibition in Fbn1(C1039G/+) mice. Our data indicate that LOX enzymes and LOX-mediated collagen accumulation play a critical protective role in aneurysm formation in MFS. Copyright © 2015 Elsevier

  10. Aortic insufficiency

    Science.gov (United States)

    ... page, please enable JavaScript. Aortic insufficiency is a heart valve disease in which the aortic valve does not close ... aortic insufficiency Images Aortic insufficiency References Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman-Cecil ...

  11. Inner tubing technique used for the treatment of anastomotic aneurism.

    Science.gov (United States)

    Gaspar, Márcio Teodoro da Costa; de Mattos, Bruno Vinicius Hortences; Sofia, Milena Cristina Dias; Mulatti, Grace Carvajal; Lederman, Alex

    2016-01-01

    The authors report the case of a 66-year-old male patient diagnosed with a pseudoaneurysm of the distal aorto-aortic anastomosis treated with the inner tubing technique. The patient had been operated on 1 year before when he had an aortic prosthesis implanted as treatment for a ruptured abdominal aortic aneurysm. The inner tubing technique was developed to facilitate the treatment in bifurcated vascular lesions, where endovascular conventional prosthesis is not available.

  12. Treatment of a Urinoma and a Post-Traumatic Pseudoaneurysm Using Selective Arterial Embolization

    International Nuclear Information System (INIS)

    Pinto, Isabel T.; Chimeno, Paloma C.

    1998-01-01

    We report a case of severe renal trauma giving rise to a pseudoaneurysm of a renal branch artery and a large urinoma secondary to fracture of a calix disconnected from the rest of the collecting system. Both conditions were successfully treated using selective arterial embolization

  13. Evaluation by MRA of aortic dilation late after repair of tetralogy of Fallot.

    Science.gov (United States)

    Kay, W Aaron; Cook, Stephen C; Daniels, Curt J

    2013-09-10

    This study evaluated predictors for aortic dilation (AD) in patients with repaired tetralogy of Fallot (rTOF) using magnetic resonance angiography (MRA). AD is common in patients with rTOF and may result in increased morbidity and mortality. There are no guidelines for evaluation of AD for rTOF patients. All adults with rTOF who previously underwent MRA had retrospective aortic measurements at the sinuses of Valsalva (SoV) and ascending aorta (AsAo). Rate of change in diameter was determined in patients with multiple MRAs. Chart review identified risk factors for AD. Univariate and multivariate analyses tested predictors of AD. Of the 87 patients who met the inclusion criteria, 12 (14%) had AD. At baseline, mean diameter was 3.6 ± 0.6 cm and 3.1 ± 0.6 cm at the SoV and AsAo, respectively. The AsAo was larger than the SoV in 17%. Predictors of AD included male gender, age, right aortic arch, pregnancy, older age at complete repair, smoking, and systemic hypertension. Serial studies were available in 55 patients; the rate of growth was slow: 0.4 ± 0.9 mm/year (SoV) and 0.1 ± 0.8mm/year (AsAo). AD is common in rTOF at the SoV and AsAo. Transthoracic echocardiography, which does not always image the AsAo as well as MRA, may not image AD in rTOF in cases in which the AsAo is dilated. Although several risk factors correlate with AD in rTOF, the rate of aortic growth is slow, suggesting that rTOF patients may not require frequent aortic imaging. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  14. Hybrid endovascular and surgical approach for mycotic pseudoaneurysms of the extracranial internal carotid artery

    Directory of Open Access Journals (Sweden)

    Daniela Mazzaccaro

    2014-11-01

    Full Text Available Objectives: Mycotic pseudoaneurysms of the extracranial internal carotid artery are rare, and their management often represents a challenge, but treatment is necessary due to the high risk of rupture and distal brain embolization. Systemic antibiotics associated with open surgical excision of the infected tissues and carotid reconstruction using autologous grafts are the treatment of choice. The use of endovascular techniques still remains controversial in infective fields; however, it can be an attractive alternative in high-risk patients or more often as a “temporary” solution to achieve immediate bleeding control for a safe surgical reconstruction. Methods: We discuss the unusual case of an extracranial right internal carotid artery mycotic pseudoaneurysm following methicillin-resistant Staphylococcus aureus infection, in a patient with poor general conditions. Results and Conclusion: The lesion was successfully treated using a hybrid endovascular and surgical procedure.

  15. Preliminary Evidence for Aortopathy and an X-Linked Parent-of-Origin Effect on Aortic Valve Malformation in a Mouse Model of Turner Syndrome

    Directory of Open Access Journals (Sweden)

    Robert B. Hinton

    2015-07-01

    Full Text Available Turner syndrome (TS, most frequently caused by X-monosomy (45,X, is characterized in part by cardiovascular abnormalities, including aortopathy and bicuspid aortic valve (BAV. There is a need for animal models that recapitulate the cardiovascular manifestations of TS. Extracellular matrix (ECM organization and morphometrics of the aortic valve and proximal aorta were examined in adult 39,XO mice (where the parental origin of the single X was paternal (39,XPO or maternal (39,XMO and 40,XX controls. Aortic valve morphology was normal (tricuspid in all of the 39,XPO and 40,XX mice studied, but abnormal (bicuspid or quadricuspid in 15% of 39,XMO mice. Smooth muscle cell orientation in the ascending aorta was abnormal in all 39,XPO and 39,XMO mice examined, but smooth muscle actin was decreased in 39,XMO mice only. Aortic dilation was present with reduced penetrance in 39,XO mice. The 39,XO mouse demonstrates aortopathy and an X-linked parent-of-origin effect on aortic valve malformation, and the candidate gene FAM9B is polymorphically expressed in control and diseased human aortic valves. The 39,XO mouse model may be valuable for examining the mechanisms underlying the cardiovascular findings in TS, and suggest there are important genetic modifiers on the X chromosome that modulate risk for nonsyndromic BAV and aortopathy.

  16. Enhanced caspase activity contributes to aortic wall remodeling and early aneurysm development in a murine model of Marfan syndrome.

    Science.gov (United States)

    Emrich, Fabian C; Okamura, Homare; Dalal, Alex R; Penov, Kiril; Merk, Denis R; Raaz, Uwe; Hennigs, Jan K; Chin, Jocelyn T; Miller, Miquell O; Pedroza, Albert J; Craig, Juliana K; Koyano, Tiffany K; Blankenberg, Francis G; Connolly, Andrew J; Mohr, Friedrich W; Alvira, Cristina M; Rabinovitch, Marlene; Fischbein, Michael P

    2015-01-01

    Rupture and dissection of aortic root aneurysms remain the leading causes of death in patients with the Marfan syndrome, a hereditary connective tissue disorder that affects 1 in 5000 individuals worldwide. In the present study, we use a Marfan mouse model (Fbn1(C1039G/+)) to investigate the biological importance of apoptosis during aneurysm development in Marfan syndrome. Using in vivo single-photon emission computed tomographic-imaging and ex vivo autoradiography for Tc99m-annexin, we discovered increased apoptosis in the Fbn1(C1039G/+) ascending aorta during early aneurysm development peaking at 4 weeks. Immunofluorescence colocalization studies identified smooth muscle cells (SMCs) as the apoptotic cell population. As biological proof of concept that early aortic wall apoptosis plays a role in aneurysm development in Marfan syndrome, Fbn1(C1039G/+) mice were treated daily from 2 to 6 weeks with either (1) a pan-caspase inhibitor, Q-VD-OPh (20 mg/kg), or (2) vehicle control intraperitoneally. Q-VD-OPh treatment led to a significant reduction in aneurysm size and decreased extracellular matrix degradation in the aortic wall compared with control mice. In vitro studies using Fbn1(C1039G/+) ascending SMCs showed that apoptotic SMCs have increased elastolytic potential compared with viable cells, mostly because of caspase activity. Moreover, in vitro (1) cell membrane isolation, (2) immunofluorescence staining, and (3) scanning electron microscopy studies illustrate that caspases are expressed on the exterior cell surface of apoptotic SMCs. Caspase inhibition attenuates aneurysm development in an Fbn1(C1039G/+) Marfan mouse model. Mechanistically, during apoptosis, caspases are expressed on the cell surface of SMCs and likely contribute to elastin degradation and aneurysm development in Marfan syndrome. © 2014 American Heart Association, Inc.

  17. Fate of coronary ostial anastomoses after the modified Bentall procedure.

    Science.gov (United States)

    Milano, Aldo D; Pratali, Stefano; Mecozzi, Gianclaudio; Boraschi, Piero; Braccini, Giovanni; Magagnini, Enrico; Bortolotti, Uberto

    2003-06-01

    Introduction of the modified Bentall procedure with the button technique has reduced but not eliminated anastomotic complications in patients receiving a composite aortic conduit. Particularly the true incidence of coronary ostial complications such as stenosis, kinking or pseudoaneurysm formation needs to be assessed. We reviewed 71 patients receiving a composite aortic conduit from November 1993 to November 1999 for chronic aneurysms (n = 51) or aortic dissection (n = 20), 12 of whom had Marfan syndrome. Patients were divided into two groups according to variations in the surgical technique. In group 1 (30 patients; 42%) the classic modified Bentall operation with the button technique was employed whereas in group 2 (41 patients; 58%) some technical modifications were added mainly consisting of a reinforcement suture joining the cut edge of the aortic wall and the prosthetic sewing ring and suture of the coronary buttons with an "endo-button" technique. To detect potential procedure-related complications particularly at the coronary ostia anastomoses follow-up included transthoracic two-dimensional echocardiography every 6 months and computerized tomographic angiography at 12 months or whenever indicated; in 20 patients a magnetic resonance imaging angiography and standard aortography with selective coronary angiography were also added. At a mean follow-up of 49 +/- 19 months anastomotic complications occurred in 4 patients (6%): in 2 a pseudoaneurysm developed at the distal aortic suture line and in 1 a pseudoaneurysm developed at the right coronary ostium after repair of acute aortic dissection; in 1 Marfan patient an aneurysm of the left coronary ostium developed. Such complications were unrelated to the two surgical techniques used in this series for reimplantaion of the coronary ostia. The modified Bentall operation is associated with an extremely low incidence of anastomotic complications particularly at the coronary ostia. More extensive use of new imaging

  18. Pseudoaneurysm of the Anterior Tibial Artery following Ankle Arthroscopy in a Soccer Player

    Directory of Open Access Journals (Sweden)

    Ichiro Tonogai

    2017-01-01

    Full Text Available Ankle arthroscopy carries a lower risk of vascular complications when standard anterolateral and anteromedial portals are used. However, the thickness of the fat pad at the anterior ankle affords little protection for the thin-walled anterior tibial artery, rendering it susceptible to indirect damage during procedures performed on the anterior ankle joint. To our knowledge, only 11 cases of pseudoaneurysm involving the anterior tibial artery after ankle arthroscopy have been described in the literature. Here we reported a rare case of a 19-year-old soccer player who presented with pseudoaneurysm of the anterior tibial artery following ankle arthroscopy using an ankle distraction method and underwent anastomosis for the anterior tibial artery injury. Excessive distraction of the ankle puts the neurovascular structures at greater risk for iatrogenic injury of the anterior tibial artery during ankle arthroscopy. Surgeons should look carefully for postoperative ankle swelling and pain after ankle arthroscopy.

  19. Anastomotic pseudoaneurysms after surgical reconstruction: Outcomes after endovascular repair of symptomatic versus asymptomatic patients

    International Nuclear Information System (INIS)

    Nolz, Richard; Gschwendtner, Manfred; Jülg, Gregor; Plank, Christina; Beitzke, Dietrich; Teufelsbauer, Harald; Wibmer, Andreas; Kretschmer, Georg; Lammer, Johannes

    2012-01-01

    Purpose: To compare perioperative and follow-up outcomes of symptomatic versus asymptomatic patients following endovascular repair of anastomotic pseudoaneurysms (APAs) of the abdominal aorta and iliac arteries. Methods: We retrospectively evaluated 17 patients (two women), with a mean age of 66.2 years (range 30–83 years). Endovascular treatment was performed in ten symptomatic, and seven asymptomatic patients electively. Data included technical success, perioperative (within 30 days) mortality and morbidity, as well as stent graft-related complications, reinterventions, and survival in follow-up. Results: Bifurcated (n = 13), aortomonoiliac (n = 3) endoprosthesis and one aortic cuff were implanted with a primary technical success rate of 100%. The overall in-hospital mortality and morbidity rate was 11.8% and 35.3%. The mean survival was 36.5 (range 0–111) months. There was a clear trend toward a lower overall survival within hospital and at one and three years for symptomatic patients compared to asymptomatic patients. (47.7 (CI: 0–138.8) versus 52.6 (CI: 28.5–76.8) months (p = 0.274)). During follow-up, late stent graft related complications were observed in six patients (35.3%) necessitating eight endovascular reinterventions. Additional three patients with primary fistulas between the APA and the intestine were treated by late surgical revision. Conclusion: Endovascular therapy of APAs represents a considerable alternative to open surgical repair. Short proximal anchoring zones still pose a risk for endoleaks and unintentional overstenting of side branches with commercially available devices, but this might be overcome by use of fenestrated and branched stent grafts in elective cases.

  20. Endovascular Treatment of an Aortoiliac Tuberculous Pseudoaneurysm

    International Nuclear Information System (INIS)

    Villegas, Miguel O.; Mereles, Alberto Pérez; Tamashiro, Gustavo A.; Dini, Andrés E.; Mollón, Ana P.; De Cándido, Laura V.; Zelaya, Denis A.; Soledispa-Suarez, Carlos I.; Denato, Sergio; Tamashiro, Alberto; Diaz, Jose A.

    2013-01-01

    We report a rare case of a tuberculous mycotic aortoiliac pseudoaneurysm treated with an endovascular procedure and follow-up of 36 months. The patient was a white 72-year-old man with pulmonary tuberculosis and a former smoker with hypertension, chronic renal failure, and dyslipidemia. A computed tomographic scan of the abdomen and pelvis revealed a left paravertebral cavity with fluid content and involvement of vertebrae L2–L4. After a surgical repair attempt, the patient was treated with the implant of a bifurcated endoprosthesis. Because it is unlikely that any center has extensive experience in the management of this rare manifestation of the disease, we reviewed the literature for similar cases.